Carlucci, Annalisa; Ceriana, Piero; Mancini, Marco; Cirio, Serena; Pierucci, Paola; D'Artavilla Lupo, Nadia; Gadaleta, Felice; Morrone, Elisa; Fanfulla, Francesco
2015-01-01
Background: Ventilation with continuous positive airway pressure (CPAP) is the gold standard therapy for obstructive sleep apnea (OSA). However, it was recently suggested that a novel mode of ventilation, Bilevel-auto, could be equally effective in treating patients unable to tolerate CPAP. The aim of this study was to investigate the ability of Bilevel-auto to treat OSA patients whose nocturnal ventilatory disturbances are not completely corrected by CPAP. Methods: We enrolled 66 consecutive OSA patients, not responsive to (group A) or intolerant of (group B) CPAP treatment, after a full night of manual CPAP titration in a laboratory. Full polysomnography data and daytime sleepiness score were compared for each group in the three different conditions: basal, during CPAP, and during Bilevel-auto. Results: The apnea-hypopnea index decreased significantly during CPAP in both groups; however, in the group A, there was a further significant improvement during Bilevel-auto. The same trend was observed for oxygenation indices, while the distribution and the efficiency of sleep did not differ following the switch from CPAP to Bilevel-auto. Conclusions: This study confirmed the role of Bilevel-auto as an effective therapeutic alternative to CPAP in patients intolerant of this latter mode of ventilation. Moreover, extending the use of Bilevel-auto to those OSA patients not responsive to CPAP, we showed a significantly better correction of nocturnal respiratory disturbances. Citation: Carlucci A, Ceriana P, Mancini M, Cirio S, Pierucci P, D'Artavilla Lupo N, Gadaleta F, Morrone E, Fanfulla F. Efficacy of Bilevel-auto treatment in patients with obstructive sleep apnea not responsive to or intolerant of continuous positive airway pressure ventilation. J Clin Sleep Med 2015;11(9):981–985. PMID:25902825
Carlucci, Annalisa; Ceriana, Piero; Mancini, Marco; Cirio, Serena; Pierucci, Paola; D'Artavilla Lupo, Nadia; Gadaleta, Felice; Morrone, Elisa; Fanfulla, Francesco
2015-09-15
Ventilation with continuous positive airway pressure (CPAP) is the gold standard therapy for obstructive sleep apnea (OSA). However, it was recently suggested that a novel mode of ventilation, Bilevel-auto, could be equally effective in treating patients unable to tolerate CPAP. The aim of this study was to investigate the ability of Bilevel-auto to treat OSA patients whose nocturnal ventilatory disturbances are not completely corrected by CPAP. We enrolled 66 consecutive OSA patients, not responsive to (group A) or intolerant of (group B) CPAP treatment, after a full night of manual CPAP titration in a laboratory. Full polysomnography data and daytime sleepiness score were compared for each group in the three different conditions: basal, during CPAP, and during Bilevel-auto. The apnea-hypopnea index decreased significantly during CPAP in both groups; however, in the group A, there was a further significant improvement during Bilevel-auto. The same trend was observed for oxygenation indices, while the distribution and the efficiency of sleep did not differ following the switch from CPAP to Bilevel-auto. This study confirmed the role of Bilevel-auto as an effective therapeutic alternative to CPAP in patients intolerant of this latter mode of ventilation. Moreover, extending the use of Bilevel-auto to those OSA patients not responsive to CPAP, we showed a significantly better correction of nocturnal respiratory disturbances. © 2015 American Academy of Sleep Medicine.
Choi, Ji Ho; Jun, Young Joon; Oh, Jeong In; Jung, Jong Yoon; Hwang, Gyu Ho; Kwon, Soon Young; Lee, Heung Man; Kim, Tae Hoon; Lee, Sang Hag; Lee, Seung Hoon
2013-05-01
The aims of the present study were twofold. We sought to compare two methods of titrating the level of continuous positive airway pressure (CPAP) - auto-adjusting titration and titration using a predictive equation - with full-night manual titration used as the benchmark. We also investigated the reliability of the two methods in patients with obstructive sleep apnea syndrome (OSAS). Twenty consecutive adult patients with OSAS who had successful, full-night manual and auto-adjusting CPAP titration participated in this study. The titration pressure level was calculated with a previously developed predictive equation based on body mass index and apnea-hypopnea index. The mean titration pressure levels obtained with the manual, auto-adjusting, and predictive equation methods were 9.0 +/- 3.6, 9.4 +/- 3.0, and 8.1 +/- 1.6 cm H2O,respectively. There was a significant difference in the concordance within the range of +/- 2 cm H2O (p = 0.019) between both the auto-adjusting titration and the titration using the predictive equation compared to the full-night manual titration. However, there was no significant difference in the concordance within the range of +/- 1 cm H2O (p > 0.999). When compared to full-night manual titration as the standard method, auto-adjusting titration appears to be more reliable than using a predictive equation for determining the optimal CPAP level in patients with OSAS.
Depression May Reduce Adherence during CPAP Titration Trial
Law, Mandy; Naughton, Matthew; Ho, Sally; Roebuck, Teanau; Dabscheck, Eli
2014-01-01
Study Objectives: Depression is a risk factor for medication non-compliance. We aimed to identify if depression is associated with poorer adherence during home-based autotitrating continuous positive airway pressure (autoPAP) titration. Design: Mixed retrospective-observational study. Setting: Academic center. Participants: Two-hundred forty continuous positive airway pressure-naïve obstructive sleep apnea (OSA) patients. Measurements: Patients underwent approximately 1 week of home-based autoPAP titration with adherence data downloaded from the device. Electronic hospital records were reviewed in a consecutive manner for inclusion. Three areas of potential predictors were examined: (i) demographics and clinical factors, (ii) disease severity, and (iii) device-related variables. Depression and anxiety were assessed using the Hospital Anxiety and Depression Scale (HADS). Scores on the subscales were categorized as normal or clinical diagnoses of depression (≥ 8) and anxiety (≥ 11). The primary outcome variable was the mean hours of autoPAP used per night. Results: Patients were diagnosed with OSA by either attended polysomnography (n = 73, AHI 25.5[15.1-41.5]) or unattended home oximetry (n = 167, ODI3 34.0[22.4-57.4]) and had home-based autoPAP titration over 6.2 ± 1.2 nights. Mean autoPAP use was 4.5 ± 2.4 hours per night. Multiple linear regression analysis revealed that depression and lower 95th percentile pressures significantly predicted lesser hours of autoPAP use (R2 = 0.19, p < 0.001). Significantly milder OSA in those requiring lower pressures may have confounded the relationship between 95th percentile pressure and autoPAP use. Conclusion: Depression was independently associated with poorer adherence during home-based autoPAP titration. Depression may be a potential target for clinicians and future research aimed at enhancing adherence to autoPAP therapy. Citation: Law M; Naughton M; Ho S; Roebuck T; Dabscheck E. Depression may reduce adherence during CPAP titration trial. J Clin Sleep Med 2014;10(2):163-169. PMID:24532999
Sowa, Mandy; Hiemann, Rico; Schierack, Peter; Reinhold, Dirk; Conrad, Karsten; Roggenbuck, Dirk
2017-08-01
Occurrence of autoantibodies (autoAbs) is a hallmark of autoimmune diseases, and the analysis thereof is an essential part in the diagnosis of organ-specific autoimmune and systemic autoimmune rheumatic diseases (SARD), especially connective tissue diseases (CTDs). Due to the appearance of autoAb profiles in SARD patients and the complexity of the corresponding serological diagnosis, different diagnostic strategies have been suggested for appropriate autoAb testing. Thus, evolving assay techniques and the continuous discovery of novel autoantigens have greatly influenced the development of these strategies. Antinuclear antibody (ANA) analysis by indirect immunofluorescence (IIF) on tissue and later cellular substrates was one of the first tests introduced into clinical routine and is still an indispensable tool for CTD serology. Thus, screening for ANA by IIF is recommended to be followed by confirmatory testing of positive findings employing different assay techniques. Given the continuous growth in the demand for autoAb testing, IIF has been challenged as the standard method for ANA and other autoAb analyses due to lacking automation, standardization, modern data management, and human bias in IIF pattern interpretation. To address these limitations of autoAb testing, the CytoBead® technique has been introduced recently which enables automated interpretation of cell-based IIF and quantitative autoAb multiplexing by addressable microbead immunoassays in one reaction environment. Thus, autoAb screening and confirmatory testing can be combined for the first time. The present review discusses the history of autoAb assay techniques in this context and gives an overview and outlook of the recent progress in emerging technologies.
Desai, Himanshu; Patel, Anil; Patel, Pinal; Grant, Brydon J B; Mador, M Jeffery
2009-11-01
Autotitrating continuous positive airway pressure (auto-CPAP) devices now have a smart card (a pocket-sized card with embedded integrated circuits which records data from the CPAP machine such as CPAP usage, CPAP pressure, large leak, etc.) which can estimate the Apnea-Hypopnea Index (AHI) on therapy. The aim of this study was to determine the accuracy of auto-CPAP in estimating the residual AHI in patients with obstructive sleep apnea (OSA) who were treated with auto-CPAP without a CPAP titration study. We studied 99 patients with OSA from April 2005 to May 2007 who underwent a repeat sleep study using auto-CPAP. The estimated AHI from auto-CPAP was compared with the AHI from an overnight polysomnogram (PSG) on auto-CPAP using Bland-Altman plot and likelihood ratio analyses. A PSG AHI cutoff of five events per hour was used to differentiate patients optimally treated with auto-CPAP from those with residual OSA on therapy. Bland and Altman analysis showed good agreement between auto-CPAP AHI and PSG AHI. There was no significant bias when smart card estimates of AHI at home were compared to smart card estimates obtained in the sleep laboratory. An auto-CPAP cutoff for the AHI of six events per hour was shown to be optimal for differentiating patients with and without residual OSA with a sensitivity of 0.92 (95% confidence interval (CI) 0.76 to 0.98) and specificity of 0.90 (95% CI 0.82 to 0.95) with a positive likelihood ratio (LR) of 9.6 (95% CI 5.1 to 21.5) and a negative likelihood ratio of 0.085 (95% CI 0.02 to 0.25). Auto-CPAP AHI of eight events per hour yielded the optimal sensitivity (0.94, 95% CI 0.73 to 0.99) and specificity (0.90, 95% CI 0.82 to 0.95) with a positive LR of 9.6 (95% CI 5.23 to 20.31) and a negative LR of 0.065 (95% CI 0.004 to 0.279) to identify patients with a PSG AHI of > or = 10 events per hour. Auto-CPAP estimate of AHI may be used to estimate residual AHI in patients with OSA of varying severity treated with auto-CPAP.
Nigro, Carlos Alberto; González, Sergio; Arce, Anabella; Aragone, María Rosario; Nigro, Luciana
2015-05-01
Patients under treatment with continuous positive airway pressure (CPAP) may have residual sleep apnea (RSA). The main objective of our study was to evaluate a novel auto-CPAP for the diagnosis of RSA. All patients referred to the sleep laboratory to undergo CPAP polysomnography were evaluated. Patients treated with oxygen or noninvasive ventilation and split-night polysomnography (PSG), PSG with artifacts, or total sleep time less than 180 min were excluded. The PSG was manually analyzed before generating the automatic report from auto-CPAP. PSG variables (respiratory disturbance index (RDI), obstructive apnea index, hypopnea index, and central apnea index) were compared with their counterparts from auto-CPAP through Bland-Altman plots and intraclass correlation coefficient. The diagnostic accuracy of autoscoring from auto-CPAP using different cutoff points of RDI (≥5 and 10) was evaluated by the receiver operating characteristics (ROCs) curve. The study included 114 patients (24 women; mean age and BMI, 59 years old and 33 kg/m(2); RDI and apnea/hypopnea index (AHI)-auto median, 5 and 2, respectively). The average difference between the AHI-auto and the RDI was -3.5 ± 3.9. The intraclass correlation coefficient (ICC) between the total number of central apneas, obstructive, and hypopneas between the PSG and the auto-CPAP were 0.69, 0.16, and 0.15, respectively. An AHI-auto >2 (RDI ≥ 5) or >4 (RDI ≥ 10) had an area under the ROC curve, sensitivity, specificity, positive likelihood ratio, and negative for diagnosis of residual sleep apnea of 0.84/0.89, 84/81%, 82/91%, 4.5/9.5, and 0.22/0.2, respectively. The automatic analysis from auto-CPAP (S9 Autoset) showed a good diagnostic accuracy to identify residual sleep apnea. The absolute agreement between PSG and auto-CPAP to classify the respiratory events correctly varied from very low (obstructive apneas, hypopneas) to moderate (central apneas).
Kim, Young Baek; Choi, Bum Ho; Lim, Yong Hwan; Yoo, Ha Na; Lee, Jong Ho; Kim, Jin Hyeok
2011-02-01
In this study, pentacene organic thin film was prepared using newly developed organic material auto-feeding system integrated with linear cell and characterized. The newly developed organic material auto-feeding system consists of 4 major parts: reservoir, micro auto-feeder, vaporizer, and linear cell. The deposition of organic thin film could be precisely controlled by adjusting feeding rate, main tube size, position and size of nozzle. 10 nm thick pentacene thin film prepared on glass substrate exhibited high uniformity of 3.46% which is higher than that of conventional evaporation method using point cell. The continuous deposition without replenishment of organic material can be performed over 144 hours with regulated deposition control. The grain size of pentacene film which affect to mobility of OTFT, was controlled as a function of the temperature.
The performance of two automatic servo-ventilation devices in the treatment of central sleep apnea.
Javaheri, Shahrokh; Goetting, Mark G; Khayat, Rami; Wylie, Paul E; Goodwin, James L; Parthasarathy, Sairam
2011-12-01
This study was conducted to evaluate the therapeutic performance of a new auto Servo Ventilation device (Philips Respironics autoSV Advanced) for the treatment of complex central sleep apnea (CompSA). The features of autoSV Advanced include an automatic expiratory pressure (EPAP) adjustment, an advanced algorithm for distinguishing open versus obstructed airway apnea, a modified auto backup rate which is proportional to subject's baseline breathing rate, and a variable inspiratory support. Our primary aim was to compare the performance of the advanced servo-ventilator (BiPAP autoSV Advanced) with conventional servo-ventilator (BiPAP autoSV) in treating central sleep apnea (CSA). A prospective, multicenter, randomized, controlled trial. Five sleep laboratories in the United States. Thirty-seven participants were included. All subjects had full night polysomnography (PSG) followed by a second night continuous positive airway pressure (CPAP) titration. All had a central apnea index ≥ 5 per hour of sleep on CPAP. Subjects were randomly assigned to 2 full-night PSGs while treated with either the previously marketed autoSV, or the new autoSV Advanced device. The 2 randomized sleep studies were blindly scored centrally. Across the 4 nights (PSG, CPAP, autoSV, and autoSV Advanced), the mean ± 1 SD apnea hypopnea indices were 53 ± 23, 35 ± 20, 10 ± 10, and 6 ± 6, respectively; indices for CSA were 16 ± 19, 19 ± 18, 3 ± 4, and 0.6 ± 1. AutoSV Advanced was more effective than other modes in correcting sleep related breathing disorders. BiPAP autoSV Advanced was more effective than conventional BiPAP autoSV in the treatment of sleep disordered breathing in patients with CSA.
NASA Astrophysics Data System (ADS)
Fangxiong, Chen; Min, Lin; Heping, Ma; Hailong, Jia; Yin, Shi; Forster, Dai
2009-08-01
An asymmetric MOSFET-C band-pass filter (BPF) with on chip charge pump auto-tuning is presented. It is implemented in UMC (United Manufacturing Corporation) 0.18 μm CMOS process technology. The filter system with auto-tuning uses a master-slave technique for continuous tuning in which the charge pump outputs 2.663 V, much higher than the power supply voltage, to improve the linearity of the filter. The main filter with third order low-pass and second order high-pass properties is an asymmetric band-pass filter with bandwidth of 2.730-5.340 MHz. The in-band third order harmonic input intercept point (IIP3) is 16.621 dBm, with 50 Ω as the source impedance. The input referred noise is about 47.455 μVrms. The main filter dissipates 3.528 mW while the auto-tuning system dissipates 2.412 mW from a 1.8 V power supply. The filter with the auto-tuning system occupies 0.592 mm2 and it can be utilized in GPS (global positioning system) and Bluetooth systems.
The accuracy of autotitrating CPAP-determined residual apnea-hypopnea index.
Cilli, Aykut; Uzun, Rusen; Bilge, Ugur
2013-03-01
Autotitrating continuous positive airway pressure (auto-CPAP) devices not only titrate CPAP pressures but also measure residual respiratory events. The aim of the present study was to determine the accuracy of auto-CPAP-derived residual apnea-hypopnea index (AHI). We studied 137 consecutive patients (72.3% men) with obstructive sleep apnea from January 2008 to December 2010 who underwent in-laboratory overnight polysomnography (PSG) using auto-CPAP. We excluded patients with comorbidities like congestive heart disease, chronic obstructive pulmonary disease, or hypoventilation syndromes and patients with central sleep apnea. Residual AHI obtained from the auto-CPAP device by smart card (CPAP-AHI) was compared simultaneously with AHI from an overnight PSG on auto-CPAP (PSG-AHI) using Bland-Altman analysis and Wilcoxon signed-rank test. The mean AHI on the diagnostic study was 45.08 ± 1.8. During the titration, auto-CPAP markedly suppressed the respiratory events (PSG-AHI, 3.40 ± 0.20). On the other hand, CPAP-AHI was 3.35 ± 0.17. Bland-Altman analysis showed good agreement between auto-CPAP-AHI and PSG-AHI (AHI mean difference of 0.05, and the limits of agreement for the AHI were from +4.9 to -4.8). Two methods have also been compared with paired samples t test and no statistically significant difference was found (p > 0.05). Auto-CPAP can identify residual respiratory events equivalent to the use of PSG in a selected population.
Evaluation of autoCPAP devices in home treatment of sleep apnea/hypopnea syndrome.
Meurice, J C; Cornette, A; Philip-Joet, F; Pepin, J L; Escourrou, P; Ingrand, P; Veale, D
2007-11-01
Quality of life (QOL) and sleepiness for patients with sleep apnea/hypopnea syndrome (SAHS) might improve with continuous positive airway pressure devices working in auto-adjust mode (autoCPAP) by allowing pressure modulations following patient needs. Clinical comparisons between devices driven by different algorithms are needed. We compared the clinical effectiveness of fixed pressure CPAP and four different autoCPAP devices by assessing compliance and QOL (36-item short-form health survey [SF-36]). SAHS patients were randomly allocated to five groups. Polysomnography (PSG) was performed to titrate the effective pressure in the constant CPAP group and evaluate residual apnea/hypopnea index (AHI) under autoCPAP. Follow-up consisted of clinical visits at three and six months by homecare technicians who assessed compliance, symptom scores and SF-36 scores. A laboratory-based PSG using the same CPAP/autoCPAP device as at home was performed at six months. Eighty-three patients (mean age 56+/-10 yrs) with mean body mass index (BMI) 30.8+/-5.3 kg/m(2) and severe SAHS (mean AHI: 52.3+/-17.8/h) were included. There were no differences in clinical symptoms or QOL scores, and similar clinical and PSG improvements were seen in all groups. CPAP use was >5 h per night, without any significant difference between groups. AutoCPAP is equally as effective as fixed CPAP for long-term home treatment in severe SAHS patients.
AutoCPAP initiation at home: optimal trial duration and cost-effectiveness.
Bachour, Adel; Virkkala, Jussi T; Maasilta, Paula K
2007-11-01
The duration of automatic computer-controlled continuous positive airway pressure device (autoCPAP) initiation at home varies largely between sleep centers. Our objectives were to evaluate the cost-effectiveness and to find the optimal trial duration. Of the 206 consecutive CPAP-naive patients with obstructive sleep apnea syndrome, who were referred to our hospital, 166 received autoCPAP for a 5-day trial at home. Of the 166 patients, 89 (15 women) showed a successful 5-day autoCPAP trial (normalized oximetry and mask-on time exceeding 4 h/day for at least 4 days). For the first trial day, 88 (53%) patients had normalized oximetry and a mask-on time exceeding 4 h. A 1-day autoCPAP trial EUR 668 was less cost-effective than a 5-day trial EUR 653, with no differences in values of efficient CPAP pressure or residual apnea-hypopnea index (AHI). The systematic requirement of oximetry monitoring raised the cost considerably from EUR 481 to EUR 668. In selected patients with obstructive sleep apnea, the optimal duration for initiating CPAP therapy at home by autoCPAP is 5 days. Although a 1-day trial was sufficient to determine the CPAP pressure requirement, it was not cost-effective and had a high rate of failure.
Fast auto-focus scheme based on optical defocus fitting model
NASA Astrophysics Data System (ADS)
Wang, Yeru; Feng, Huajun; Xu, Zhihai; Li, Qi; Chen, Yueting; Cen, Min
2018-04-01
An optical defocus fitting model-based (ODFM) auto-focus scheme is proposed. Considering the basic optical defocus principle, the optical defocus fitting model is derived to approximate the potential-focus position. By this accurate modelling, the proposed auto-focus scheme can make the stepping motor approach the focal plane more accurately and rapidly. Two fitting positions are first determined for an arbitrary initial stepping motor position. Three images (initial image and two fitting images) at these positions are then collected to estimate the potential-focus position based on the proposed ODFM method. Around the estimated potential-focus position, two reference images are recorded. The auto-focus procedure is then completed by processing these two reference images and the potential-focus image to confirm the in-focus position using a contrast based method. Experimental results prove that the proposed scheme can complete auto-focus within only 5 to 7 steps with good performance even under low-light condition.
Autonomous Navigation Performance During The Hartley 2 Comet Flyby
NASA Technical Reports Server (NTRS)
Abrahamson, Matthew J; Kennedy, Brian A.; Bhaskaran, Shyam
2012-01-01
On November 4, 2010, the EPOXI spacecraft performed a 700-km flyby of the comet Hartley 2 as follow-on to the successful 2005 Deep Impact prime mission. EPOXI, an extended mission for the Deep Impact Flyby spacecraft, returned a wealth of visual and infrared data from Hartley 2, marking the fifth time that high-resolution images of a cometary nucleus have been captured by a spacecraft. The highest resolution science return, captured at closest approach to the comet nucleus, was enabled by use of an onboard autonomous navigation system called AutoNav. AutoNav estimates the comet-relative spacecraft trajectory using optical measurements from the Medium Resolution Imager (MRI) and provides this relative position information to the Attitude Determination and Control System (ADCS) for maintaining instrument pointing on the comet. For the EPOXI mission, AutoNav was tasked to enable continuous tracking of a smaller, more active Hartley 2, as compared to Tempel 1, through the full encounter while traveling at a higher velocity. To meet the mission goal of capturing the comet in all MRI science images, position knowledge accuracies of +/- 3.5 km (3-?) cross track and +/- 0.3 seconds (3-?) time of flight were required. A flight-code-in-the-loop Monte Carlo simulation assessed AutoNav's statistical performance under the Hartley 2 flyby dynamics and determined optimal configuration. The AutoNav performance at Hartley 2 was successful, capturing the comet in all of the MRI images. The maximum residual between observed and predicted comet locations was 20 MRI pixels, primarily influenced by the center of brightness offset from the center of mass in the observations and attitude knowledge errors. This paper discusses the Monte Carlo-based analysis that led to the final AutoNav configuration and a comparison of the predicted performance with the flyby performance.
The Role of Cultural Context in Continuing Vocational Training: A Study on Auto Repairmen in Turkey
ERIC Educational Resources Information Center
Akbas, Oktay
2011-01-01
This study analysed how auto repairmen working in micro-enterprises undertake continuing vocational training in relation to cultural context. The study was conducted in Kirikkale, a city in central Anatolia in Turkey. To this end, the descriptive research technique of structured interview was used. Interviews with 33 auto repairmen were recorded…
47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...
47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...
47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...
47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...
47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...
Cha, Dong Ik; Lee, Min Woo; Kim, Ah Yeong; Kang, Tae Wook; Oh, Young-Taek; Jeong, Ja-Yeon; Chang, Jung-Woo; Ryu, Jiwon; Lee, Kyong Joon; Kim, Jaeil; Bang, Won-Chul; Shin, Dong Kuk; Choi, Sung Jin; Koh, Dalkwon; Seo, Bong Koo; Kim, Kyunga
2017-11-01
Background A major drawback of conventional manual image fusion is that the process may be complex, especially for less-experienced operators. Recently, two automatic image fusion techniques called Positioning and Sweeping auto-registration have been developed. Purpose To compare the accuracy and required time for image fusion of real-time ultrasonography (US) and computed tomography (CT) images between Positioning and Sweeping auto-registration. Material and Methods Eighteen consecutive patients referred for planning US for radiofrequency ablation or biopsy for focal hepatic lesions were enrolled. Image fusion using both auto-registration methods was performed for each patient. Registration error, time required for image fusion, and number of point locks used were compared using the Wilcoxon signed rank test. Results Image fusion was successful in all patients. Positioning auto-registration was significantly faster than Sweeping auto-registration for both initial (median, 11 s [range, 3-16 s] vs. 32 s [range, 21-38 s]; P < 0.001] and complete (median, 34.0 s [range, 26-66 s] vs. 47.5 s [range, 32-90]; P = 0.001] image fusion. Registration error of Positioning auto-registration was significantly higher for initial image fusion (median, 38.8 mm [range, 16.0-84.6 mm] vs. 18.2 mm [6.7-73.4 mm]; P = 0.029), but not for complete image fusion (median, 4.75 mm [range, 1.7-9.9 mm] vs. 5.8 mm [range, 2.0-13.0 mm]; P = 0.338]. Number of point locks required to refine the initially fused images was significantly higher with Positioning auto-registration (median, 2 [range, 2-3] vs. 1 [range, 1-2]; P = 0.012]. Conclusion Positioning auto-registration offers faster image fusion between real-time US and pre-procedural CT images than Sweeping auto-registration. The final registration error is similar between the two methods.
SU-E-J-112: The Impact of Cine EPID Image Acquisition Frame Rate On Markerless Soft-Tissue Tracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yip, S; Rottmann, J; Berbeco, R
2014-06-01
Purpose: Although reduction of the cine EPID acquisition frame rate through multiple frame averaging may reduce hardware memory burden and decrease image noise, it can hinder the continuity of soft-tissue motion leading to poor auto-tracking results. The impact of motion blurring and image noise on the tracking performance was investigated. Methods: Phantom and patient images were acquired at a frame rate of 12.87Hz on an AS1000 portal imager. Low frame rate images were obtained by continuous frame averaging. A previously validated tracking algorithm was employed for auto-tracking. The difference between the programmed and auto-tracked positions of a Las Vegas phantommore » moving in the superior-inferior direction defined the tracking error (δ). Motion blurring was assessed by measuring the area change of the circle with the greatest depth. Additionally, lung tumors on 1747 frames acquired at eleven field angles from four radiotherapy patients are manually and automatically tracked with varying frame averaging. δ was defined by the position difference of the two tracking methods. Image noise was defined as the standard deviation of the background intensity. Motion blurring and image noise were correlated with δ using Pearson correlation coefficient (R). Results: For both phantom and patient studies, the auto-tracking errors increased at frame rates lower than 4.29Hz. Above 4.29Hz, changes in errors were negligible with δ<1.60mm. Motion blurring and image noise were observed to increase and decrease with frame averaging, respectively. Motion blurring and tracking errors were significantly correlated for the phantom (R=0.94) and patient studies (R=0.72). Moderate to poor correlation was found between image noise and tracking error with R -0.58 and -0.19 for both studies, respectively. Conclusion: An image acquisition frame rate of at least 4.29Hz is recommended for cine EPID tracking. Motion blurring in images with frame rates below 4.39Hz can substantially reduce the accuracy of auto-tracking. This work is supported in part by the Varian Medical Systems, Inc.« less
Incidence of auto-immune pemphigus in the Midi-Pyrénées region in 2002-2006.
Thomas, M; Paul, C; Berard, E; Fortenfant, F; Mazereeuw-Hautier, J; Livideanu, C; Viraben, R; Meyer, N
2010-01-01
Auto-immune pemphigus is an organ-specific immune disorder due to pathogenic auto-antibodies. Both genetic and environmental factors have been associated with the occurrence of auto-immune pemphigus. Little is known about the epidemiology of auto-immune pemphigus in western Europe. To evaluate the incidence of auto-immune pemphigus in south-western France (namely the Midi-Pyrénées region) in a 5-year period between 2002 and 2006. We performed a retrospective study of the annual incidence of auto-immune pemphigus diagnosed in the Midi-Pyrénées region, between January 1, 2002, and December 31, 2006. Possible cases of pemphigus were initially selected using skin direct immunofluorescence (DIF) databases from all laboratories in the Midi-Pyrénées region. Systematic validation of all cases was performed by two of the authors (N.M., M.T.). To qualify as a case of auto-immune pemphigus, patients had to fulfil the following criteria: history of clinical signs of pemphigus as assessed by a dermatologist and a positive DIF. To be included in the study, validated cases of auto-immune pemphigus had to fulfil the following criteria: the date of first positive skin DIF between January 1, 2002, and December 31, 2006, and patient living in the Midi-Pyrénées region at the time of the first positive skin DIF. Between 2002 and 2006, 91 patients with positive DIF were identified. Fifty-four patients with positive DIF did not meet the validation criteria for the study. Thirty-seven cases were included in the analysis. The crude annual mean incidence of auto-immune pemphigus between 2002 and 2006 was 2.7 cases/10(6) inhabitants/year (95% CI: 1.87-3.69). The world-population-standardized annual mean incidence of auto-immune pemphigus was 1.55 (95% CI: 0.99-2.11). We report a 1.55/10(6) inhabitants/year world-population-standardized incidence of auto-immune pemphigus in the south-west of France. A nationwide epidemiological study of pemphigus should be performed in France.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Atkinson, P; Chen, Q
2016-06-15
Purpose: To assess the clinical efficacy of auto beam hold during prostate RapidArc delivery, triggered by fiducial localization on kV imaging with a Varian True Beam. Methods: Prostate patients with four gold fiducials were candidates in this study. Daily setup was accomplished by aligning to fiducials using orthogonal kV imaging. During RapidArc delivery, a kV image was automatically acquired with a momentary beam hold every 60 degrees of gantry rotation. The position of each fiducial was identified by a search algorithm and compared to a predetermined 1.4 cm diameter target area. Treatment continued if all the fiducials were within themore » target area. If any fiducial was outside the target area the beam hold was not released, and the operators determined if the patient needed re-alignment using the daily setup method. Results: Four patients were initially selected. For three patients, the auto beam hold performed seamlessly. In one instance, the system correctly identified misaligned fiducials, stopped treatment, and the patient was re-positioned. The fourth patient had a prosthetic hip which sometimes blocked the fiducials and caused the fiducial search algorithm to fail. The auto beam hold was disabled for this patient and the therapists manually monitored the fiducial positions during treatment. Average delivery time for a 2-arc fraction was increased by 59 seconds. Phantom studies indicated the dose discrepancy related to multiple beam holds is <0.1%. For a plan with 43 fractions, the additional imaging increased dose by an estimated 68 cGy. Conclusion: Automated intrafraction kV imaging can effectively perform auto beam holds due to patient movement, with the exception of prosthetic hip patients. The additional imaging dose and delivery time are clinically acceptable. It may be a cost-effective alternative to Calypso in RapidArc prostate patient delivery. Further study is warranted to explore its feasibility under various clinical conditions.« less
46 CFR 97.16-1 - Use of auto pilot.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Use of auto pilot. 97.16-1 Section 97.16-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Auto Pilot § 97.16-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
46 CFR 97.16-1 - Use of auto pilot.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Use of auto pilot. 97.16-1 Section 97.16-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Auto Pilot § 97.16-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
46 CFR 78.19-1 - Use of auto pilot.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 3 2012-10-01 2012-10-01 false Use of auto pilot. 78.19-1 Section 78.19-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Auto Pilot § 78.19-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used in— (a...
46 CFR 97.16-1 - Use of auto pilot.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Use of auto pilot. 97.16-1 Section 97.16-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Auto Pilot § 97.16-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
46 CFR 78.19-1 - Use of auto pilot.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 3 2014-10-01 2014-10-01 false Use of auto pilot. 78.19-1 Section 78.19-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Auto Pilot § 78.19-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used in— (a...
46 CFR 78.19-1 - Use of auto pilot.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 3 2013-10-01 2013-10-01 false Use of auto pilot. 78.19-1 Section 78.19-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Auto Pilot § 78.19-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used in— (a...
46 CFR 97.16-1 - Use of auto pilot.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Use of auto pilot. 97.16-1 Section 97.16-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Auto Pilot § 97.16-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
46 CFR 78.19-1 - Use of auto pilot.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 3 2010-10-01 2010-10-01 false Use of auto pilot. 78.19-1 Section 78.19-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Auto Pilot § 78.19-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used in— (a...
46 CFR 78.19-1 - Use of auto pilot.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 3 2011-10-01 2011-10-01 false Use of auto pilot. 78.19-1 Section 78.19-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Auto Pilot § 78.19-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used in— (a...
46 CFR 97.16-1 - Use of auto pilot.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Use of auto pilot. 97.16-1 Section 97.16-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Auto Pilot § 97.16-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
Stitching-aware in-design DPT auto fixing for sub-20nm logic devices
NASA Astrophysics Data System (ADS)
Choi, Soo-Han; Sai Krishna, K. V. V. S.; Pemberton-Smith, David
2017-03-01
As the technology continues to shrink below 20nm, Double Patterning Technology (DPT) becomes one of the mandatory solutions for routing metal layers. From the view point of Place and Route (P&R), the major concerns are how to prevent DPT odd-cycles automatically without sacrificing chip area. Even though the leading-edge P&R tools have advanced algorithms to prevent DPT odd-cycles, it is very hard to prevent the localized DPT odd-cycles, especially in Engineering Change Order (ECO) routing. In the last several years, we developed In-design DPT Auto Fixing method in order to reduce localized DPT odd-cycles significantly during ECO and could achieve remarkable design Turn-Around Times (TATs). But subsequently, as the design complexity continued increasing and chip size continued decreasing, we needed a new In-design DPT Auto Fixing approach to improve the auto. fixing rate. In this paper, we present the Stitching-Aware In-design DPT Auto Fixing method for better fixing rates and smaller chip design. The previous In-design DPT Auto Fixing method detected all DPT odd-cycles and tried to remove oddcycles by increasing the adjacent space. As the metal congestions increase in the newer technology nodes, the older Auto Fixing method has limitations to increase the adjacent space between routing metals. Consequently, the auto fixing rate of older method gets worse with the introduction of the smaller design rules. With DPT stitching enablement at In-design DRC checking procedure, the new Stitching-Aware DPT Auto Fixing method detects the most critical odd-cycles and revolve the odd-cycles automatically. The accuracy of new flow ensures better usage of space in the congested areas, and helps design more smaller chips. By applying the Stitching-Aware DPT Auto Fixing method to sub-20nm logic devices, we can confirm that the auto fixing rate is improved by 2X compared with auto fixing without stitching. Additionally, by developing the better heuristic algorithm and flow for DPT stitching, we can get DPT compliant layout with the acceptable design TATs.
Bellani, Giacomo; Coppadoro, Andrea; Patroniti, Nicolò; Turella, Marta; Arrigoni Marocco, Stefano; Grasselli, Giacomo; Mauri, Tommaso; Pesenti, Antonio
2014-09-01
Auto-positive end-expiratory pressure (auto-PEEP) may substantially increase the inspiratory effort during assisted mechanical ventilation. Purpose of this study was to assess whether the electrical activity of the diaphragm (EAdi) signal can be reliably used to estimate auto-PEEP in patients undergoing pressure support ventilation and neurally adjusted ventilatory assist (NAVA) and whether NAVA was beneficial in comparison with pressure support ventilation in patients affected by auto-PEEP. In 10 patients with a clinical suspicion of auto-PEEP, the authors simultaneously recorded EAdi, airway, esophageal pressure, and flow during pressure support and NAVA, whereas external PEEP was increased from 2 to 14 cm H2O. Tracings were analyzed to measure apparent "dynamic" auto-PEEP (decrease in esophageal pressure to generate inspiratory flow), auto-EAdi (EAdi value at the onset of inspiratory flow), and IDEAdi (inspiratory delay between the onset of EAdi and the inspiratory flow). The pressure necessary to overcome auto-PEEP, auto-EAdi, and IDEAdi was significantly lower in NAVA as compared with pressure support ventilation, decreased with increase in external PEEP, although the effect of external PEEP was less pronounced in NAVA. Both auto-EAdi and IDEAdi were tightly correlated with auto-PEEP (r = 0.94 and r = 0.75, respectively). In the presence of auto-PEEP at lower external PEEP levels, NAVA was characterized by a characteristic shape of the airway pressure. In patients with auto-PEEP, NAVA, compared with pressure support ventilation, led to a decrease in the pressure necessary to overcome auto-PEEP, which could be reliably monitored by the electrical activity of the diaphragm before inspiratory flow onset (auto-EAdi).
Demir, E; Yeğit, O; Erol, A; Akgül, S U; Çalışkan, B; Bayraktar, A; Çalışkan, Y; Türkmen, A; Savran, F O; Sever, M S
2017-04-01
The crossmatch test is essential prior to kidney transplantation (tx) to confirm compatibility between the donor and the recipient. However, its results can be misleading due to "undetectable antibodies" in the recipient's serum. To establish if undetectable autoantibodies are responsible for a positive result, an auto-crossmatch test can be performed. In this study, we aim to determine the long-term prognostic value of auto-flow cytometric auto-crossmatch (FCXM) test on kidney survival in kidney tx recipients. The primary outcome variable was reduced renal function. Secondary endpoints were incidence of biopsy-confirmed chronic antibody-mediated rejection (CAMR) and recurrent glomerulonephritis (GN). There were no differences regarding initial serum creatinine levels between the study and control groups (P = .441). Patients who had positive auto-B FCXM had a significantly reduced renal function compared with the control group (P = .016). Four patients developed biopsy-confirmed CAMR in the study group and 1 patient in the control group (P = .047). Five patients had biopsy-confirmed recurrent GN in the GN study group, and only 1 patient had recurrent GN in the GN control group (P = .026). Kidney transplant recipients with positive auto-FCXM test had significantly reduced renal function and a higher incidence of recurrent GN and CAMR compared with the control group. The findings of this study suggest a potential role of auto-antibody causing positive auto-FCXM test result, meanwhile increasing the risk of CAMR, recurrent GN, and new-onset diabetes after tx. Copyright © 2017 Elsevier Inc. All rights reserved.
46 CFR 185.360 - Use of auto pilot.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Use of auto pilot. 185.360 Section 185.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.360 Use of auto pilot. Whenever an automatic pilot is...
46 CFR 131.960 - Use of auto-pilot.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Use of auto-pilot. 131.960 Section 131.960 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Miscellaneous § 131.960 Use of auto-pilot. When the automatic pilot is used in areas of high traffic density...
46 CFR 185.360 - Use of auto pilot.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Use of auto pilot. 185.360 Section 185.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.360 Use of auto pilot. Whenever an automatic pilot is...
46 CFR 131.960 - Use of auto-pilot.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Use of auto-pilot. 131.960 Section 131.960 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Miscellaneous § 131.960 Use of auto-pilot. When the automatic pilot is used in areas of high traffic density...
46 CFR 131.960 - Use of auto-pilot.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Use of auto-pilot. 131.960 Section 131.960 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Miscellaneous § 131.960 Use of auto-pilot. When the automatic pilot is used in areas of high traffic density...
46 CFR 185.360 - Use of auto pilot.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Use of auto pilot. 185.360 Section 185.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.360 Use of auto pilot. Whenever an automatic pilot is...
46 CFR 131.960 - Use of auto-pilot.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Use of auto-pilot. 131.960 Section 131.960 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Miscellaneous § 131.960 Use of auto-pilot. When the automatic pilot is used in areas of high traffic density...
46 CFR 185.360 - Use of auto pilot.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Use of auto pilot. 185.360 Section 185.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.360 Use of auto pilot. Whenever an automatic pilot is...
46 CFR 185.360 - Use of auto pilot.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Use of auto pilot. 185.360 Section 185.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.360 Use of auto pilot. Whenever an automatic pilot is...
46 CFR 131.960 - Use of auto-pilot.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Use of auto-pilot. 131.960 Section 131.960 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Miscellaneous § 131.960 Use of auto-pilot. When the automatic pilot is used in areas of high traffic density...
Hanaya, Junko; Nakamura, Yasuko; Nejima, Ryouhei; Miyata, Kazunori; Mera, Kentarou; Ohguro, Hiroshi; Yamamoto, Shuichi
2011-06-01
We report a case of melanoma-associated retinopathy (MAR) associated with positive auto-antibodies against retinal bipolar cells, which has been rarely reported in Japan. A 33 year-old woman noticed shimmering vision, photopsias, blurred vision, and night blindness OS in April 2009, and visited Kagoshima Miyata Eye Clinic in May 2009. She had been continuously treated for malignant melanoma on her left finger since 2007. At her initial visit, the corrected visual acuity was 1.5 OD and 1.2 OS, and slit-lamp examination revealed clear ocular media OU. Funduscopic examination showed normal appearance of the retina OU, except for a mild narrowing of the retinal arteries OS. Humphrey field analyzer revealed a reduction of retinal sensitivity within the central 30 degrees OS. The maximum left eye response of electroretinogram (ERG) showed a negative waveform. The immuno-cytochemical test revealed antibodies against retinal bipolar cells, which confirmed the diagnosis of MAR. Characteristic subjective symptoms, Humphrey field analyzer and ERG are useful for the diagnosis of MAR.
Bakker, Jessie P; Neill, Alister M; Campbell, Angela J
2012-09-01
This single-blinded, randomized, controlled pilot study aimed to investigate whether there is a difference between nasal and oronasal masks in therapeutic continuous positive airway pressure (CPAP) requirement, residual disease, or leak when treating obstructive sleep apnea (OSA) and if differences were related to measures of upper airway size. Patients with severe OSA currently using CPAP at ≥4 h/night with a nasal mask were examined (including Mallampati scale, incisal relationship, and mandibular protrusion) and then randomized to receive auto-positive airway pressure (PAP) or fixed CPAP at a manually titrated pressure for 1 week each at home, with immediate crossover. Within each week, a nasal mask and two oronasal masks were to be used for two or three nights each in random order. Data were downloaded from the device. Twelve patients completed the trial (mean ± SD AHI 59.8 ± 28.6 events/h; CPAP 11.1 ± 3.2 cmH(2)O; BMI 37.7 ± 5.0 kg/m(2)). During auto-PAP, the median 95th percentile pressure delivered with all masks was within 0.5 cmH(2)O (p > 0.05). During CPAP, median residual AHI was 0.61 (IQR = 1.18) for the nasal mask, 1.70 (IQR = 4.04) for oronasal mask 1, and 2.48 (IQR = 3.74) for oronasal mask 2 (p = 0.03). The 95th percentile leak was lowest with the nasal mask during both CPAP and auto-PAP (both p < 0.01). Differences in pressure or residual disease were not related to measures of upper airway shape or body habitus. In obese OSA patients changing from a nasal to oronasal mask increased leak and residual AHI but did not affect the therapeutic pressure requirement. The findings of the current study highlight mask leak as the major difficulty in the use of oronasal masks.
46 CFR 109.585 - Use of auto pilot.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Use of auto pilot. 109.585 Section 109.585 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.585 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
46 CFR 109.585 - Use of auto pilot.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Use of auto pilot. 109.585 Section 109.585 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.585 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
46 CFR 109.585 - Use of auto pilot.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Use of auto pilot. 109.585 Section 109.585 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.585 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
46 CFR 109.585 - Use of auto pilot.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Use of auto pilot. 109.585 Section 109.585 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.585 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
46 CFR 109.585 - Use of auto pilot.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Use of auto pilot. 109.585 Section 109.585 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.585 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
46 CFR 122.360 - Use of auto pilot.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Use of auto pilot. 122.360 Section 122.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... Requirements § 122.360 Use of auto pilot. Whenever an automatic pilot is used the master shall ensure that: (a...
46 CFR 122.360 - Use of auto pilot.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Use of auto pilot. 122.360 Section 122.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... Requirements § 122.360 Use of auto pilot. Whenever an automatic pilot is used the master shall ensure that: (a...
46 CFR 122.360 - Use of auto pilot.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Use of auto pilot. 122.360 Section 122.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... Requirements § 122.360 Use of auto pilot. Whenever an automatic pilot is used the master shall ensure that: (a...
46 CFR 122.360 - Use of auto pilot.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Use of auto pilot. 122.360 Section 122.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... Requirements § 122.360 Use of auto pilot. Whenever an automatic pilot is used the master shall ensure that: (a...
46 CFR 122.360 - Use of auto pilot.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Use of auto pilot. 122.360 Section 122.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... Requirements § 122.360 Use of auto pilot. Whenever an automatic pilot is used the master shall ensure that: (a...
Auto Body Welding 2 (Course Outline), Automotive Body Repair and Refinishing 1: 9033.04.
ERIC Educational Resources Information Center
Dade County Public Schools, Miami, FL.
The 90-hour course is a foundation quinmester course in welding for the auto body repairman. The outline consists of seven blocks of instruction (orientation, 6 hours; auto body oxyacetylene welding, 10 hours; electric arc welding equipment, 6 hours; auto body electric arc welding, 8 hours; position welding, 40 hours; electric spot welders, 16…
46 CFR 167.65-35 - Use of auto pilot.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Use of auto pilot. 167.65-35 Section 167.65-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS Special Operating Requirements § 167.65-35 Use of auto pilot. Except as provided in 33 CFR 164.15, when...
Su, Mei; Huai, De; Cao, Juan; Ning, Ding; Xue, Rong; Xu, Meijie; Huang, Mao; Zhang, Xilong
2018-03-01
Although bilevel positive airway pressure (Bilevel PAP) therapy is usually used for overlap syndrome (OS), there is still a portion of OS patients in whom Bilevel PAP therapy could not simultaneously eliminate residual apnea events and hypercapnia. The current study was expected to explore whether auto-trilevel positive airway pressure (auto-trilevel PAP) therapy with auto-adjusting end expiratory positive airway pressure (EEPAP) can serve as a better alternative for these patients. From January of 2014 to June of 2016, 32 hypercapnic OS patients with stable chronic obstructive pulmonary diseases (COPD) and moderate-to-severe obstructive sleep apnea syndrome (OSAS) were recruited. Three variable modes of positive airway pressure (PAP) from the ventilator (Prisma25ST, Weinmann Inc., Germany) were applicated for 8 h per night. We performed the design of each mode at each night with an interval of two nights with no PAP treatment as a washout period among different modes. In Bilevel-1 mode (Bilevel-1), the expiratory positive airway pressure (EPAP) delivered from Bilevel PAP was always set as the lowest PAP for abolishment of snoring. For each patient, the inspiratory positive airway pressure (IPAP) was constantly set the same as the minimal pressure for keeping end-tidal CO 2 (ETCO 2 ) ≤45 mmHg for all three modes. However, the EPAP issued by Bilevel PAP in Bilevel-2 mode (Bilevel-2) was kept 3 cmH 2 O higher than that in Bilevel-1. In auto-trilevel mode (auto-trilevel) with auto-trilevel PAP, the initial part of EPAP was fixed at the same PAP as that in Bilevel-1 while the EEPAP was automatically regulated to rise at a range of ≤4 cmH 2 O based on nasal airflow wave changes. Comparisons were made for parameters before and during or following treatment as well as among different PAP therapy modes. The following parameters were compared such as nocturnal apnea hypopnea index (AHI), minimal SpO 2 (minSpO 2 ), arousal index, sleep structure and efficiency, morning PaCO 2 , and daytime Epworth Sleepiness Scale (ESS). Compared with the parameters before PAP therapies, during each mode of PAP treatment, significant reduction was detected in nocturnal AHI, arousal index, morning PaCO 2 , and daytime ESS while significant elevation was revealed in nocturnal minSpO 2 and sleep efficiency (all P < 0.01). Comparison among three PAP modes indicated that under the same IPAP, the auto-trilevel PAP mode could result in the lowest arousal index, daytime ESS, and the highest sleep efficiency. Compared with Bilevel-1, it was detected that (a) AHI was lower but minSpO 2 was higher in both Bilevel-2 and auto-trilevel (all P < 0.05) and (b) morning PaCO 2 showed no statistical difference from that in auto-trilevel but displayed higher in Bilevel-2 (P < 0.05). Compared with Bilevel-2, in auto-trilevel, both AHI and minSpO 2 showed no obvious changes (all P > 0.05) except with a lower morning PaCO 2 (P < 0.05). Auto-trilevel PAP therapy was superior over conventional Bilevel PAP therapy for hypercapnic OS patients with their OSAS moderate to severe, since auto-trilevel PAP was more efficacious in synchronous elimination of residual obstructive apnea events and CO 2 retention as well as in obtaining a better sleep quality and milder daytime drowsiness.
Luo, Jiaying; Xiao, Sichang; Qiu, Zhihui; Song, Ning; Luo, Yuanming
2013-04-01
Whether the therapeutic nasal continuous positive airway pressure (CPAP) derived from manual titration is the same as derived from automatic titration is controversial. The purpose of this study was to compare the therapeutic pressure derived from manual titration with automatic titration. Fifty-one patients with obstructive sleep apnoea (OSA) (mean apnoea/hypopnoea index (AHI) = 50.6 ± 18.6 events/h) who were newly diagnosed after an overnight full polysomnography and who were willing to accept CPAP as a long-term treatment were recruited for the study. Manual titration during full polysomnography monitoring and unattended automatic titration with an automatic CPAP device (REMstar Auto) were performed. A separate cohort study of one hundred patients with OSA (AHI = 54.3 ± 18.9 events/h) was also performed by observing the efficacy of CPAP derived from manual titration. The treatment pressure derived from automatic titration (9.8 ± 2.2 cmH(2)O) was significantly higher than that derived from manual titration (7.3 ± 1.5 cmH(2)O; P < 0.001) in 51 patients. The cohort study of 100 patients showed that AHI was satisfactorily decreased after CPAP treatment using a pressure derived from manual titration (54.3 ± 18.9 events/h before treatment and 3.3 ± 1.7 events/h after treatment; P < 0.001). The results suggest that automatic titration pressure derived from REMstar Auto is usually higher than the pressure derived from manual titration. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.
Wang, Linwei; Mohammad, Sohaib H.; Li, Qiaozhi; Rienthong, Somsak; Rienthong, Dhanida; Nedsuwan, Supalert; Mahasirimongkol, Surakameth; Yasui, Yutaka
2014-01-01
There is an urgent need for simple, rapid, and affordable diagnostic tests for tuberculosis (TB) to combat the great burden of the disease in developing countries. The microscopic observation drug susceptibility assay (MODS) is a promising tool to fill this need, but it is not widely used due to concerns regarding its biosafety and efficiency. This study evaluated the automated MODS (Auto-MODS), which operates on principles similar to those of MODS but with several key modifications, making it an appealing alternative to MODS in resource-limited settings. In the operational setting of Chiang Rai, Thailand, we compared the performance of Auto-MODS with the gold standard liquid culture method in Thailand, mycobacterial growth indicator tube (MGIT) 960 plus the SD Bioline TB Ag MPT64 test, in terms of accuracy and efficiency in differentiating TB and non-TB samples as well as distinguishing TB and multidrug-resistant (MDR) TB samples. Sputum samples from clinically diagnosed TB and non-TB subjects across 17 hospitals in Chiang Rai were consecutively collected from May 2011 to September 2012. A total of 360 samples were available for evaluation, of which 221 (61.4%) were positive and 139 (38.6%) were negative for mycobacterial cultures according to MGIT 960. Of the 221 true-positive samples, Auto-MODS identified 212 as positive and 9 as negative (sensitivity, 95.9%; 95% confidence interval [CI], 92.4% to 98.1%). Of the 139 true-negative samples, Auto-MODS identified 135 as negative and 4 as positive (specificity, 97.1%; 95% CI, 92.8% to 99.2%). The median time to culture positivity was 10 days, with an interquartile range of 8 to 13 days for Auto-MODS. Auto-MODS is an effective and cost-sensitive alternative diagnostic tool for TB diagnosis in resource-limited settings. PMID:25378569
Physics suggests that the interplay of momentum, continuity, and geometry in outward radial flow must produce density and concomitant pressure reductions. In other words, this flow is intrinsically auto-expansive. It has been proposed that this process is the key to understanding...
Baigorri, F; de Monte, A; Blanch, L; Fernández, R; Vallés, J; Mestre, J; Saura, P; Artigas, A
1994-11-01
To study the effect of positive end-expiratory pressure (PEEP) on right ventricular hemodynamics and ejection fraction in patients with chronic obstructive pulmonary disease and positive alveolar pressure throughout expiration by dynamic hyperinflation (auto-PEEP). Open, prospective, controlled trial. General intensive care unit of a community hospital. Ten patients sedated and paralyzed with an acute exacerbation of chronic obstructive pulmonary disease undergoing mechanical ventilation. Insertion of a pulmonary artery catheter modified with a rapid response thermistor and a radial arterial catheter. PEEP was then increased from 0 (PEEP 0) to auto-PEEP level (PEEP = auto-PEEP) and 5 cm H2O above that (PEEP = auto-PEEP +5). At each level of PEEP, airway pressures, flow and volume, hemodynamic variables (including right ventricular ejection fraction by thermodilution technique), and blood gas analyses were recorded. The mean auto-PEEP was 6.6 +/- 2.8 cm H2O and the total PEEP reached was 12.2 +/- 2.4 cm H2O. The degree of lung inflation induced by PEEP averaged 145 +/- 87 mL with PEEP = auto-PEEP and 495 +/- 133 mL with PEEP = auto-PEEP + 5. The PEEP = auto-PEEP caused a right ventricular end-diastolic pressure increase, but there was no other significant hemodynamic change. With PEEP = auto-PEEP + 5, there was a significant increase in intravascular pressures; this amount of PEEP reduced cardiac output (from 4.40 +/- 1.38 L/min at PEEP 0 to 4.13 +/- 1.48 L/min; p < .05). The cardiac output reduction induced by PEEP = auto-PEEP + 5 was > 10% in only five cases and this group of patients had significantly lower right ventricular volumes than the group with less cardiac output variation (right ventricular end-diastolic volume: 64 +/- 9 vs. 96 +/- 26 mL/m2; right ventricular end-systolic volume: 38 +/- 6 vs. 65 +/- 21 mL/m2; p < .05) without significant difference in the other variables that were measured. Neither right ventricular ejection fraction nor right ventricle volumes changed as PEEP increased, but there were marked interpatient differences and also pronounced changes in volume between stages in individual patients. In the study conditions, PEEP application up to values approaching auto-PEEP did not result in the impairment of right ventricular hemodynamics, while higher levels reduced cardiac output in selected patients.
Lived Experience as Pedagogical Resource: Towards an Auto-Ethnographic Pedagogy of Writing
ERIC Educational Resources Information Center
Voorhees, T.
2016-01-01
The key element of auto-ethnography, as distinct from memoir and autobiography, is the positioning of the writer within the social, cultural, economic, and political framework of what is being observed. T. Voorhees saw immense value in this positioning for students today, especially newer college students who understand their relationship to…
Fast and Adaptive Auto-focusing Microscope
NASA Astrophysics Data System (ADS)
Obara, Takeshi; Igarashi, Yasunobu; Hashimoto, Koichi
Optical microscopes are widely used in biological and medical researches. By using the microscope, we can observe cellular movements including intracellular ions and molecules tagged with fluorescent dyes at a high magnification. However, a freely motile cell easily escapes from a 3D field of view of the typical microscope. Therefore, we propose a novel auto-focusing algorithm and develop a auto-focusing and tracking microscope. XYZ positions of a microscopic stage are feedback controlled to focus and track the cell automatically. A bright-field image is used to estimate a cellular position. XY centroids are used to estimate XY positions of the tracked cell. To estimate Z position, we use a diffraction pattern around the cell membrane. This estimation method is so-called Depth from Diffraction (DFDi). However, this method is not robust for individual differences between cells because the diffraction pattern depends on each cellular shape. Therefore, in this study, we propose a real-time correction of DFDi by using 2D Laplacian of an intracellular area as a goodness of the focus. To evaluate the performance of our developed algorithm and microscope, we auto-focus and track a freely moving paramecium. In this experimental result, the paramecium is auto-focused and kept inside the scope of the microscope during 45s. The evaluated focal error is within 5µm, while a length and a thickness of the paramecium are about 200µm and 50µm, respectively.
Nasal continuous positive airway pressure treatment: current realities and future.
Berthon-Jones, M; Lawrence, S; Sullivan, C E; Grunstein, R
1996-11-01
Nasal continuous positive airway pressure (CPAP) is a highly effective treatment for obstructive sleep apnea syndrome. The apnea/hypopnea index (AHI) is reduced 10-fold, but the patient dropout rate is up to 30%, and usage is typically < 5 hours per night. Titration, designed to make the best trade-off between effectiveness and side effects, is expensive. Autotitrating devices make this trade-off on a minute-by-minute basis, potentially reducing mean pressure delivery, reducing side effects, and increasing compliance. The aim of this study was to test the effectiveness of the AutoSet self-adjusting nasal CPAP system (ResMed, Sydney, Australia) in eliminating obstructive events and normalizing the arousal index. Forty-five subjects (41 males and 4 females with AHI) values of > 20/hour were recruited, with written informed consent. Subjects slept for a diagnostic night, followed by a treatment night, in the laboratory, using the AutoSet system with full polysomnographic monitoring of respiratory and sleep variables. Arousals were scored using ASDA criteria. Hypopneas were scored when there was a 50% reduction in ventilation for > 10 seconds, associated with a 4% drop in oxygen saturation. For comparison, the ASDA arousal index in 16 normal subjects (without nasal CPAP) is provided. Results are given as mean +/- standard error of the mean. AHI was reduced from 55 +/- 3 to 1.5 +/- 0.35 events/hour (p < 0.0001). The arousal index was reduced from 65 +/- 3 to 18 +/- 2 events/hour (p < 0.0001), identical to the value in the 16 healthy normal subjects. There was a 158% +/- 21% increase in slow-wave sleep (p = 0.01) and a 186% +/- 27% increase in rapid eye movement sleep (p = 0.013). The AutoSet self-adjusting nasal CPAP system adequately treats obstructive sleep apnea syndrome on the first night under laboratory conditions.
Shi, Hai-Bo; Cheng, Lei; Nakayama, Meiho; Kakazu, Yasuhiro; Yin, Min; Miyoshi, Akira; Komune, Shizuo
2005-09-01
Automatic continuous positive airway pressure (auto-CPAP) machines differ mainly in algorithms used for respiratory event detection and pressure control. The auto-CPAP machines operated by novel algorithms are expected to have better performance than the earlier ones in the treatment of obstructive sleep apnea syndrome (OSAS). The purpose of this study was to determine the therapeutic characteristics between two different auto-CPAP devices, i.e., the third-generation flow-based (f-APAP) and the second-generation vibration-based (v-APAP) machines, during the first night treatment of OSAS. We retrospectively reviewed the polysomnography (PSG) recordings of 43 OSAS patients who were initially performed an overnight diagnostic PSG to confirm the disease and afterwards received the first night auto-CPAP treatment with using either the f-APAP (n=22) or v-APAP (n=21) device under another PSG evaluation. There were 13.6% and 61.9% patients who remained a residual apnea/hypopnea index more than 5 during the f-APAP and v-APAP application, respectively (P<0.005). The f-APAP was more effective than the v-APAP in reducing apnea/hypopnea index (P=0.003), hypopnea index (P=0.023) and apnea index (P=0.007), improving the lowest oxygen saturation index (P=0.007) and shortening stage 1 sleep (P=0.016). However, the f-APAP was less sufficient than the v-APAP in reducing arousal/awakening index (P=0.02). These findings suggest that the f-APAP works better than the v-APAP in abolishing breathing abnormities in the treatment of OSAS; however, the f-APAP device might still have some potential limitations in the clinical application.
Empiric auto-titrating CPAP in people with suspected obstructive sleep apnea.
Drummond, Fitzgerald; Doelken, Peter; Ahmed, Qanta A; Gilbert, Gregory E; Strange, Charlie; Herpel, Laura; Frye, Michael D
2010-04-15
Efficient diagnosis and treatment of obstructive sleep apnea (OSA) can be difficult because of time delays imposed by clinic visits and serial overnight polysomnography. In some cases, it may be desirable to initiate treatment for suspected OSA prior to polysomnography. Our objective was to compare the improvement of daytime sleepiness and sleep-related quality of life of patients with high clinical likelihood of having OSA who were randomly assigned to receive empiric auto-titrating continuous positive airway pressure (CPAP) while awaiting polysomnogram versus current usual care. Serial patients referred for overnight polysomnography who had high clinical likelihood of having OSA were randomly assigned to usual care or immediate initiation of auto-titrating CPAP. Epworth Sleepiness Scale (ESS) scores and the Functional Outcomes of Sleep Questionnaire (FOSQ) scores were obtained at baseline, 1 month after randomization, and again after initiation of fixed CPAP in control subjects and after the sleep study in auto-CPAP patients. One hundred nine patients were randomized. Baseline demographics, daytime sleepiness, and sleep-related quality of life scores were similar between groups. One-month ESS and FOSQ scores were improved in the group empirically treated with auto-titrating CPAP. ESS scores improved in the first month by a mean of -3.2 (confidence interval -1.6 to -4.8, p < 0.001) and FOSQ scores improved by a mean of 1.5, (confidence interval 0.5 to 2.7, p = 0.02), whereas scores in the usual-care group did not change (p = NS). Following therapy directed by overnight polysomnography in the control group, there were no differences in ESS or FOSQ between the groups. No adverse events were observed. Empiric auto-CPAP resulted in symptomatic improvement of daytime sleepiness and sleep-related quality of life in a cohort of patients awaiting polysomnography who had a high pretest probability of having OSA. Additional studies are needed to evaluate the applicability of empiric treatment to other populations.
ERIC Educational Resources Information Center
Sagan, Olivia
2007-01-01
This paper explores the auto/biographicity of ethnographic research, describing the way in which our research pursuits can be seen as the replaying of past agendas. It looks specifically at the auto/biographic interview as part of the ethnographic data collected, positing it as the site of co-construction of new memory, and the re-enactment of…
47 CFR 80.305 - Watch requirements of the Communications Act and the Safety Convention.
Code of Federal Regulations, 2010 CFR
2010-10-01
... having a loudspeaker and a radiotelephone auto alarm must be used to keep the continuous watch on 2182 k... navigation of the ship, the watch may be maintained by use of the radiotelephone auto alarm facility alone...
Empiric Auto-Titrating CPAP in People with Suspected Obstructive Sleep Apnea
Drummond, Fitzgerald; Doelken, Peter; Ahmed, Qanta A.; Gilbert, Gregory E.; Strange, Charlie; Herpel, Laura; Frye, Michael D.
2010-01-01
Objective: Efficient diagnosis and treatment of obstructive sleep apnea (OSA) can be difficult because of time delays imposed by clinic visits and serial overnight polysomnography. In some cases, it may be desirable to initiate treatment for suspected OSA prior to polysomnography. Our objective was to compare the improvement of daytime sleepiness and sleep-related quality of life of patients with high clinical likelihood of having OSA who were randomly assigned to receive empiric auto-titrating continuous positive airway pressure (CPAP) while awaiting polysomnogram versus current usual care. Methods: Serial patients referred for overnight polysomnography who had high clinical likelihood of having OSA were randomly assigned to usual care or immediate initiation of auto-titrating CPAP. Epworth Sleepiness Scale (ESS) scores and the Functional Outcomes of Sleep Questionnaire (FOSQ) scores were obtained at baseline, 1 month after randomization, and again after initiation of fixed CPAP in control subjects and after the sleep study in auto-CPAP patients. Results: One hundred nine patients were randomized. Baseline demographics, daytime sleepiness, and sleep-related quality of life scores were similar between groups. One-month ESS and FOSQ scores were improved in the group empirically treated with auto-titrating CPAP. ESS scores improved in the first month by a mean of −3.2 (confidence interval −1.6 to −4.8, p < 0.001) and FOSQ scores improved by a mean of 1.5, (confidence interval 0.5 to 2.7, p = 0.02), whereas scores in the usual-care group did not change (p = NS). Following therapy directed by overnight polysomnography in the control group, there were no differences in ESS or FOSQ between the groups. No adverse events were observed. Conclusion: Empiric auto-CPAP resulted in symptomatic improvement of daytime sleepiness and sleep-related quality of life in a cohort of patients awaiting polysomnography who had a high pretest probability of having OSA. Additional studies are needed to evaluate the applicability of empiric treatment to other populations. Citation: Drummond F; Doelken P; Ahmed QA; Gilbert GE; Strange C; Herpel L; Frye MD. Empiric auto-titrating CPAP in people with suspected obstructive sleep apnea. J Clin Sleep Med 2010;6(2):140-145. PMID:20411690
Salvaggio, Adriana; Lo Bue, Anna; Isidoro, Serena Iacono; Romano, Salvatore; Marrone, Oreste; Insalaco, Giuseppe
2016-01-01
To determine whether the use of a gel pillow with side cutouts designed to accommodate a continuous positive airway pressure (CPAP) mask and reduce head temperature improves the efficacy of and adherence to auto-CPAP therapy. Twenty-three consecutive CPAP-naïve patients with obstructive sleep apnea were enrolled in the study. Patients were given an auto-CPAP machine with an appropriate CPAP mask and were instructed to use CPAP for 15 nights. They were instructed to sleep with their own pillow (the control pillow) from nights 1 to 5 and with either a foam pillow or a gel pillow, both of which had side cutouts, for 5 consecutive nights each, in random order. After night 15, auto-CPAP machine data were downloaded and patients rated their satisfaction with each pillow on a visual analog scale. Twenty-two patients completed the protocol. The pressures administered, residual apnea-hypopnea index, air leaks, and mean duration of CPAP use did not differ among the periods during which each pillow was used. Patients were significantly more satisfied with the gel pillow than with the control pillow and the foam pillow (p = 0.022 and p = 0.004, respectively), their level of satisfaction with the gel pillow correlating significantly with excessive daytime sleepiness (r2 = 0.19; p = 0.0443). Among obstructive sleep apnea patients treated with nasal CPAP, the use of a gel pillow with side cutouts appears to have no impact on treatment effectiveness. Nevertheless, such patients seem to prefer a gel pillow over other types of pillows. Determinar se o uso de um travesseiro de gel com recortes laterais para acomodar a máscara de continuous positive airway pressure (CPAP, pressão positiva contínua nas vias aéreas) e diminuir a temperatura em torno da cabeça melhora a eficácia do tratamento com auto-CPAP e a adesão dos pacientes ao tratamento. Foram incluídos no estudo 23 pacientes consecutivos com apneia obstrutiva do sono que nunca haviam recebido tratamento com CPAP. Os pacientes receberam um aparelho de auto-CPAP com uma máscara apropriada e foram instruídos a usar CPAP durante 15 noites. Foram também instruídos a dormir com seu próprio travesseiro (o travesseiro controle) nas 5 primeiras noites e com um travesseiro de espuma ou um travesseiro de gel, ambos com recortes laterais, durante 5 noites consecutivas cada, em ordem aleatória. Depois da 15ª noite, os dados registrados nos aparelhos de auto-CPAP foram baixados e os pacientes determinaram seu grau de satisfação com cada travesseiro por meio de uma escala visual analógica. Vinte e dois pacientes completaram o protocolo. Não houve diferenças entre os períodos durante os quais cada travesseiro foi usado quanto às pressões administradas, índice de apneia-hipopneia residual, vazamentos de ar e média de duração da CPAP. Os pacientes ficaram significativamente mais satisfeitos com o travesseiro de gel do que com o travesseiro controle e o travesseiro de espuma (p = 0,022 e p = 0,004, respectivamente), com correlação entre o grau de satisfação com o travesseiro de gel e a sonolência diurna excessiva (r2 = 0,19; p = 0,0443). Em pacientes com apneia obstrutiva do sono tratados com CPAP nasal, o uso de um travesseiro de gel com recortes laterais aparentemente não tem nenhum impacto na eficácia do tratamento. No entanto, esses pacientes aparentemente preferem um travesseiro de gel a outros tipos de travesseiros.
Should we systematically test patients with clinically isolated syndrome for auto-antibodies?
Negrotto, Laura; Tur, Carmen; Tintoré, Mar; Arrambide, Georgina; Sastre-Garriga, Jaume; Río, Jordi; Comabella, Manuel; Nos, Carlos; Galán, Ingrid; Vidal-Jordana, Angela; Simon, Eva; Castilló, Joaquín; Palavra, Filipe; Mitjana, Raquel; Auger, Cristina; Rovira, Àlex; Montalban, Xavier
2015-12-01
Several autoimmune diseases (ADs) can mimic multiple sclerosis (MS). For this reason, testing for auto-antibodies (auto-Abs) is often included in the diagnostic work-up of patients with a clinically isolated syndrome (CIS). The purpose was to study how useful it was to systematically determine antinuclear-antibodies, anti-SSA and anti-SSB in a non-selected cohort of CIS patients, regarding the identification of other ADs that could represent an alternative diagnosis. From a prospective CIS cohort, we selected 772 patients in which auto-Ab levels were tested within the first year from CIS. Baseline characteristics of auto-Ab positive and negative patients were compared. A retrospective revision of clinical records was then performed in the auto-Ab positive patients to identify those who developed ADs during follow-up. One or more auto-Ab were present in 29.4% of patients. Only 1.8% of patients developed other ADs during a mean follow-up of 6.6 years. In none of these cases the concurrent AD was considered the cause of the CIS. In all cases the diagnosis of the AD resulted from the development of signs and/or symptoms suggestive of each disease. Antinuclear-antibodies, anti-SSA and anti-SSB should not be routinely determined in CIS patients but only in those presenting symptoms suggestive of other ADs. © The Author(s), 2015.
Error Estimation for the Linearized Auto-Localization Algorithm
Guevara, Jorge; Jiménez, Antonio R.; Prieto, Jose Carlos; Seco, Fernando
2012-01-01
The Linearized Auto-Localization (LAL) algorithm estimates the position of beacon nodes in Local Positioning Systems (LPSs), using only the distance measurements to a mobile node whose position is also unknown. The LAL algorithm calculates the inter-beacon distances, used for the estimation of the beacons’ positions, from the linearized trilateration equations. In this paper we propose a method to estimate the propagation of the errors of the inter-beacon distances obtained with the LAL algorithm, based on a first order Taylor approximation of the equations. Since the method depends on such approximation, a confidence parameter τ is defined to measure the reliability of the estimated error. Field evaluations showed that by applying this information to an improved weighted-based auto-localization algorithm (WLAL), the standard deviation of the inter-beacon distances can be improved by more than 30% on average with respect to the original LAL method. PMID:22736965
Latshang, Tsogyal D; Nussbaumer-Ochsner, Yvonne; Henn, Rahel M; Ulrich, Silvia; Lo Cascio, Christian M; Ledergerber, Bruno; Kohler, Malcolm; Bloch, Konrad E
2012-12-12
Many patients with obstructive sleep apnea syndrome (OSA) living near sea level travel to altitude, but this may expose them to hypoxemia and exacerbation of sleep apnea. The treatment in this setting is not established. To evaluate whether acetazolamide and autoadjusted continuous positive airway pressure (autoCPAP) control breathing disturbances in OSA patients at altitude. Randomized, placebo-controlled, double-blind, crossover trial involving 51 patients with OSA living below an altitude of 800 m and receiving CPAP therapy who underwent studies at a university hospital at 490 m and resorts in Swiss mountain villages at 1630 m and 2590 m in summer 2009. Patients were studied during 2 sojourns of 3 days each in mountain villages, 2 days at 1630 m, 1 day at 2590 m, separated by a 2-week washout period at less than 800 m. At altitude, patients either took acetazolamide (750 mg/d) or placebo in addition to autoCPAP. Primary outcomes were nocturnal oxygen saturation and the apnea/hypopnea index; secondary outcomes were sleep structure, vigilance, symptoms, adverse effects, and exercise performance. Acetazolamide and autoCPAP treatment was associated with higher nocturnal oxygen saturation at 1630 m and 2590 m than placebo and autoCPAP: medians, 94% (interquartile range [IQR], 93%-95%) and 91% (IQR, 90%-92%) vs 93% (IQR, 92%-94%) and 89% (IQR, 87%-91%), respectively. Median increases were 1.0% (95% CI, 0.3%-1.0%) and 2.0% (95% CI, 2.0%-2.0). Median night-time spent with oxygen saturation less than 90% at 2590 m was 13% (IQR, 2%-38%) vs 57% (IQR, 28%-82%; P < .001). Acetazolamide and autoCPAP resulted in better control of sleep apnea at 1630 m and 2590 m than placebo and autoCPAP: median apnea/hypopnea index was 5.8 events per hour (5.8/h) (IQR, 3.0/h-10.1/h) and 6.8/h (IQR, 3.5/h-10.1/h) vs 10.7/h (IQR, 5.1/h-17.7/h) and 19.3/h (IQR, 9.3/h-29.0/h), respectively; median reduction was 3.2/h (95% CI, 1.3/h-7.5/h) and 9.2 (95% CI, 5.1/h-14.6/h). Among patients with OSA spending 3 days at moderately elevated altitude, a combination of acetazolamide and autoCPAP therapy, compared with autoCPAP alone, resulted in improvement in nocturnal oxygen saturation and apnea/hypopnea index. clinicaltrials.gov Identifier: NCT00928655.
Parmar, S; Kongtim, P; Champlin, R; Dinh, Y; Elgharably, Y; Wang, M; Bashir, Q; Shah, J J; Shah, N; Popat, U; Giralt, S A; Orlowski, R Z; Qazilbash, M H
2014-08-01
Optimal treatment approach continues to remain a challenge for systemic light chain amyloidosis (AL). So far, Auto-SCT is the only modality associated with long-term survival. However, failure to show survival benefit in randomized study raises questions regarding its efficacy. We present a comparative outcome analysis of Auto-SCT to conventional therapies (CTR) in AL patients treated over a 14-year period at our institution. Out of the 145 AL amyloidosis patients, Auto-SCT was performed in 80 patients with 1-year non-relapse mortality rate of 12.5%. Novel agents were used as part of induction therapy in 56% of transplant recipients vs 46% of CTR patients. Hematological and organ responses were seen in 74.6% and 39% in the Auto-SCT arm vs 53% and 12% in the CTR arm, respectively. The projected 5-year survival for Auto-SCT vs CTR was 63% vs 38%, respectively. Landmark analysis of patients alive at 1-year after diagnosis showed improved 5-year OS of 72% with Auto-SCT vs 65% in the CTR arm. In the multivariate analysis, age <60 years, induction therapy with novel agents, kidney only involvement and Auto-SCT were associated with improved survival. In conclusion, Auto-SCT is associated with long-term survival for patients with AL amyloidosis.
Automatized set-up procedure for transcranial magnetic stimulation protocols.
Harquel, S; Diard, J; Raffin, E; Passera, B; Dall'Igna, G; Marendaz, C; David, O; Chauvin, A
2017-06-01
Transcranial Magnetic Stimulation (TMS) established itself as a powerful technique for probing and treating the human brain. Major technological evolutions, such as neuronavigation and robotized systems, have continuously increased the spatial reliability and reproducibility of TMS, by minimizing the influence of human and experimental factors. However, there is still a lack of efficient set-up procedure, which prevents the automation of TMS protocols. For example, the set-up procedure for defining the stimulation intensity specific to each subject is classically done manually by experienced practitioners, by assessing the motor cortical excitability level over the motor hotspot (HS) of a targeted muscle. This is time-consuming and introduces experimental variability. Therefore, we developed a probabilistic Bayesian model (AutoHS) that automatically identifies the HS position. Using virtual and real experiments, we compared the efficacy of the manual and automated procedures. AutoHS appeared to be more reproducible, faster, and at least as reliable as classical manual procedures. By combining AutoHS with robotized TMS and automated motor threshold estimation methods, our approach constitutes the first fully automated set-up procedure for TMS protocols. The use of this procedure decreases inter-experimenter variability while facilitating the handling of TMS protocols used for research and clinical routine. Copyright © 2017 Elsevier Inc. All rights reserved.
A new approach to the form and position error measurement of the auto frame surface based on laser
NASA Astrophysics Data System (ADS)
Wang, Hua; Li, Wei
2013-03-01
Auto frame is a very large workpiece, with length up to 12 meters and width up to 2 meters, and it's very easy to know that it's inconvenient and not automatic to measure such a large workpiece by independent manual operation. In this paper we propose a new approach to reconstruct the 3D model of the large workpiece, especially the auto truck frame, based on multiple pulsed lasers, for the purpose of measuring the form and position errors. In a concerned area, it just needs one high-speed camera and two lasers. It is a fast, high-precision and economical approach.
Virtual Screening with AutoDock: Theory and Practice
Cosconati, Sandro; Forli, Stefano; Perryman, Alex L.; Harris, Rodney; Goodsell, David S.; Olson, Arthur J.
2011-01-01
Importance to the field Virtual screening is a computer-based technique for identifying promising compounds to bind to a target molecule of known structure. Given the rapidly increasing number of protein and nucleic acid structures, virtual screening continues to grow as an effective method for the discovery of new inhibitors and drug molecules. Areas covered in this review We describe virtual screening methods that are available in the AutoDock suite of programs, and several of our successes in using AutoDock virtual screening in pharmaceutical lead discovery. What the reader will gain A general overview of the challenges of virtual screening is presented, along with the tools available in the AutoDock suite of programs for addressing these challenges. Take home message Virtual screening is an effective tool for the discovery of compounds for use as leads in drug discovery, and the free, open source program AutoDock is an effective tool for virtual screening. PMID:21532931
Analysis on the workspace of palletizing robot based on AutoCAD
NASA Astrophysics Data System (ADS)
Li, Jin-quan; Zhang, Rui; Guan, Qi; Cui, Fang; Chen, Kuan
2017-10-01
In this paper, a four-degree-of-freedom articulated palletizing robot is used as the object of research. Based on the analysis of the overall configuration of the robot, the kinematic mathematical model is established by D-H method to figure out the workspace of the robot. In order to meet the needs of design and analysis, using AutoCAD secondary development technology and AutoLisp language to develop AutoCAD-based 2D and 3D workspace simulation interface program of palletizing robot. At last, using AutoCAD plugin, the influence of structural parameters on the shape and position of the working space is analyzed when the structure parameters of the robot are changed separately. This study laid the foundation for the design, control and planning of palletizing robots.
2012-01-01
auto focusing mechanisms, energy harvesting , and pico air vehicle design. Their advantages include nanometer positioning resolution, broadband frequency...high speed camera shutters and auto focusing mechanisms energy harvesting , and pico air vehicle design. Their advantages include nanometer positioning...THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 Nomenclature d Piezoelectric constant (m/V = C/N) h
NASA Astrophysics Data System (ADS)
Liu, W.; Wang, H.; Liu, D.; Miu, Y.
2018-05-01
Precise geometric parameters are essential to ensure the positioning accuracy for space optical cameras. However, state-of-the-art onorbit calibration method inevitably suffers from long update cycle and poor timeliness performance. To this end, in this paper we exploit the optical auto-collimation principle and propose a real-time onboard calibration scheme for monitoring key geometric parameters. Specifically, in the proposed scheme, auto-collimation devices are first designed by installing collimated light sources, area-array CCDs, and prisms inside the satellite payload system. Through utilizing those devices, the changes in the geometric parameters are elegantly converted into changes in the spot image positions. The variation of geometric parameters can be derived via extracting and processing the spot images. An experimental platform is then set up to verify the feasibility and analyze the precision index of the proposed scheme. The experiment results demonstrate that it is feasible to apply the optical auto-collimation principle for real-time onboard monitoring.
What factors affect the carriage of epinephrine auto-injectors by teenagers?
Macadam, Clare; Barnett, Julie; Roberts, Graham; Stiefel, Gary; King, Rosemary; Erlewyn-Lajeunesse, Michel; Holloway, Judith A; Lucas, Jane S
2012-02-02
Teenagers with allergies are at particular risk of severe and fatal reactions, but epinephrine auto-injectors are not always carried as prescribed. We investigated barriers to carriage. Patients aged 12-18 years old under a specialist allergy clinic, who had previously been prescribed an auto-injector were invited to participate. Semi-structured interviews explored the factors that positively or negatively impacted on carriage. Twenty teenagers with food or venom allergies were interviewed. Only two patients had used their auto-injector in the community, although several had been treated for severe reactions in hospital. Most teenagers made complex risk assessments to determine whether to carry the auto-injector. Most but not all decisions were rational and were at least partially informed by knowledge. Factors affecting carriage included location, who else would be present, the attitudes of others and physical features of the auto-injector. Teenagers made frequent risk assessments when deciding whether to carry their auto-injectors, and generally wanted to remain safe. Their decisions were complex, multi-faceted and highly individualised. Rather than aiming for 100% carriage of auto-injectors, which remains an ambitious ideal, personalised education packages should aim to empower teenagers to make and act upon informed risk assessments.
Prompting Technology and Persons With Dementia: The Significance of Context and Communication.
Braley, Rachel; Fritz, Rochelle; Van Son, Catherine R; Schmitter-Edgecombe, Maureen
2018-06-12
Smart home auto-prompting has the potential to increase the functional independence of persons with dementia (PWDs) and decrease caregiver burden as instrumental activities of daily living (IADLs) are completed at home. To improve prompting technologies, we sought to inductively understand how PWDs responded to auto-prompting while performing IADL tasks. Fifteen PWDs completed eight IADLs in a smart home testbed and received a hierarchy of verbal auto-prompts (indirect, direct, multimodal) as needed for task completion. Two researchers viewed archived videos and recorded the observed behaviors of the PWDs and their reflections watching the PWDs. Using qualitative descriptive methods, an interdisciplinary analytic team reviewed transcripts and organized data into themes using content analysis. Context and Communication emerged as the major themes, suggesting that positive user experiences will require auto-prompting systems to account for a multitude of contextual factors (individual and environmental) such as level of cognitive impairment, previous exposure to task, and familiarity of environment. Communicating with another human rather than an automated prompting system may be important if individuals begin to exhibit signs of stress while completing activities. Additional work is needed to create auto-prompting systems that provide specific, personalized, and flexible prompts. Holistic conceptualization of "successful task completion" is needed and a positive end-user experience will be key to utility. Such systems will benefit from including positive reinforcement, training, and exploration of how, and whether, direct human involvement can be minimized during the provision of in-home care.
DAT positivity in blood donors: a perplexing scenario.
Bedi, Ravneet Kaur; Mittal, Kshitija; Sood, Tanvi; Kumar, Rakesh; Praveen, Ajay S
2014-04-01
A blood request was received for 70 year male patient suffering from Chronic Obstructive Pulmonary Disease with anemia. One unit was found incompatible in AHG phase. Patient's antibody screen, indirect antiglobulin test (IAT), direct antiglobulin test (DAT) and auto control was negative. DAT of donor unit was positive with anti IgG gel card and negative with C3d reagent along with positive auto control. Donor was 30 year male with no history of blood transfusion and medication and had no evidence of hemolysis. Donors with positive DAT should be deferred, notified and referred to physician but further studies are required. Copyright © 2014 Elsevier Ltd. All rights reserved.
Blood screening in a southern Nigeria City: a case study with SAVAN.
Ehikhamenor, Edeaghe; Azodo, Clement; Chinedu, Ekeh; Festus, Eghieme
2009-10-01
Commercial motorcycle transportation and motorbike riding in Nigeria is prevalent, and road traffic accidents often result. Characteristic of such accidents is massive blood loss, thus exerting extreme pressure on the blood bank for replenishment and screening. The need to galvanize the system to design a blood bank with minimal bureaucracy and easy access led to screening for blood group. A delay in accessing blood for the victims leads to higher mortality. Our approach was to establish a pre-crash blood data for all auto-bike riders who participated in Save Accident Victims Association of Nigeria (SAVAN, an indigenous, nongovernmental organization) training program. Data used were obtained from 1250 auto-bike riders who volunteered at our workshop. Tile grouping method was used for the screening. Blood group O positive (54.3%) was the most common blood group type among the auto-bike riders studied, with A positive following at 20.3 percent, B positive at 18.8 percent, O negative at 3.7 percent, AB positive at 1.3 percent, B negative at 1.1 percent, and A negative at 0.5 percent. It was observed that none of the volunteers grouped AB negative. Blood group of auto-bike riders, pedestrians, passengers, and all potential victims should be documented in their identification card to facilitate blood transfusion during major crisis or disasters where the facilities for typing are not available.
Randell, Edward W; Short, Garry; Lee, Natasha; Beresford, Allison; Spencer, Margaret; Kennell, Marina; Moores, Zoë; Parry, David
2018-06-01
Six Sigma involves a structured process improvement strategy that places processes on a pathway to continued improvement. The data presented here summarizes a project that took three clinical laboratories from autoverification processes that allowed between about 40% to 60% of tests being auto-verified to more than 90% of tests and samples auto-verified. The project schedule, metrics and targets, a description of the previous system and detailed information on the changes made to achieve greater than 90% auto-verification is presented for this Six Sigma DMAIC (Design, Measure, Analyze, Improve, Control) process improvement project.
NASA Astrophysics Data System (ADS)
Jiang, Jingtao; Sui, Rendong; Shi, Yan; Li, Furong; Hu, Caiqi
In this paper 3-D models of combined fixture elements are designed, classified by their functions, and saved in computer as supporting elements library, jointing elements library, basic elements library, localization elements library, clamping elements library, and adjusting elements library etc. Then automatic assembly of 3-D combined checking fixture for auto-body part is presented based on modularization theory. And in virtual auto-body assembly space, Locating constraint mapping technique and assembly rule-based reasoning technique are used to calculate the position of modular elements according to localization points and clamp points of auto-body part. Auto-body part model is transformed from itself coordinate system space to virtual assembly space by homogeneous transformation matrix. Automatic assembly of different functional fixture elements and auto-body part is implemented with API function based on the second development of UG. It is proven in practice that the method in this paper is feasible and high efficiency.
ERIC Educational Resources Information Center
West, Linden
2014-01-01
In this article, I interrogate the changing forms that may be fundamental to transformative learning and how these are best chronicled and understood. Drawing on auto/biographical narrative research, I challenge the continuing primacy of a kind of overly disembodied, decontextualized cognition as the basis of transformation. Notions of epistemic…
Female Infertility and Serum Auto-antibodies: a Systematic Review.
Deroux, Alban; Dumestre-Perard, Chantal; Dunand-Faure, Camille; Bouillet, Laurence; Hoffmann, Pascale
2017-08-01
On average, 10 % of infertile couples have unexplained infertility. Auto-immune disease (systemic lupus erythematosus, anti-phospholipid syndrome) accounts for a part of these cases. In the last 20 years, aspecific auto-immunity, defined as positivity of auto-antibodies in blood sample without clinical or biological criteria for defined diseases, has been evoked in a subpopulation of infertile women. A systematic review was performed (PUBMED) using the MESH search terms "infertility" and "auto-immunity" or "reproductive technique" or "assisted reproduction" or "in vitro fertilization" and "auto-immunity." We retained clinical and physiopathological studies that were applicable to the clinician in assuming joint management of both infertility associated with serum auto-antibodies in women. Thyroid auto-immunity which affects thyroid function could be a cause of infertility; even in euthyroidia, the presence of anti-thyroperoxydase antibodies and/or thyroglobulin are related to infertility. The presence of anti-phospholipid (APL) and/or anti-nuclear (ANA) antibodies seems to be more frequent in the population of infertile women; serum auto-antibodies are associated with early ovarian failure, itself responsible for fertility disorders. However, there exist few publications on this topic. The methods of dosage, as well as the clinical criteria of unexplained infertility deserve to be standardized to allow a precise response to the question of the role of serum auto-antibodies in these women. The direct pathogenesis of this auto-immunity is unknown, but therapeutic immunomodulators, prescribed on a case-by-case basis, could favor pregnancy even in cases of unexplained primary or secondary infertility.
Krakow, Barry; Ulibarri, Victor A; McIver, Natalia D; Nadorff, Michael R
2016-09-29
Evidence indicates that behavioral or drug therapy may not target underlying pathophysiologic mechanisms for chronic insomnia, possibly due to previously unrecognized high rates (30%-90%) of sleep apnea in chronic insomnia patients. Although treatment studies with positive airway pressure (PAP) demonstrate decreased severity of chronic sleep maintenance insomnia in patients with co-occurring sleep apnea, sleep-onset insomnia has not shown similar results. We hypothesized advanced PAP technology would be associated with decreased sleep-onset insomnia severity in a sample of predominantly psychiatric patients with comorbid sleep apnea. We reviewed charts of 74 severe sleep-onset insomnia patients seen from March 2011 to August 2015, all meeting American Academy of Sleep Medicine Work Group criteria for a chronic insomnia disorder and all affirming behavioral and psychological origins for insomnia (averaging 10 of 18 indicators/patient), as well as averaging 2 or more psychiatric symptoms or conditions: depression (65.2%), anxiety (41.9%), traumatic exposure (35.1%), claustrophobia (29.7%), panic attacks (28.4%), and posttraumatic stress disorder (20.3%). All patients failed continuous or bilevel PAP and were manually titrated with auto-adjusting PAP modes (auto-bilevel and adaptive-servo ventilation). At 1-year follow-up, patients were compared through nonrandom assignment on the basis of a PAP compliance metric of > 20 h/wk (56 PAP users) versus < 20 h/wk (18 partial PAP users). PAP users showed significantly greater decreases in global insomnia severity (Hedges' g = 1.72) and sleep-onset insomnia (g = 2.07) compared to partial users (g = 1.04 and 0.91, respectively). Both global and sleep-onset insomnia severity decreased below moderate levels in PAP users compared to partial users whose outcomes persisted at moderately severe levels. In a nonrandomized controlled retrospective study, advanced PAP technology (both auto-bilevel and adaptive servo-ventilation) were associated with large decreases in insomnia severity for sleep-onset insomnia patients who strongly believed psychological factors caused their sleeplessness. PAP treatment of sleep-onset insomnia merits further investigation. © Copyright 2016 Physicians Postgraduate Press, Inc.
What factors affect the carriage of epinephrine auto-injectors by teenagers?
2012-01-01
Background Teenagers with allergies are at particular risk of severe and fatal reactions, but epinephrine auto-injectors are not always carried as prescribed. We investigated barriers to carriage. Methods Patients aged 12-18 years old under a specialist allergy clinic, who had previously been prescribed an auto-injector were invited to participate. Semi-structured interviews explored the factors that positively or negatively impacted on carriage. Results Twenty teenagers with food or venom allergies were interviewed. Only two patients had used their auto-injector in the community, although several had been treated for severe reactions in hospital. Most teenagers made complex risk assessments to determine whether to carry the auto-injector. Most but not all decisions were rational and were at least partially informed by knowledge. Factors affecting carriage included location, who else would be present, the attitudes of others and physical features of the auto-injector. Teenagers made frequent risk assessments when deciding whether to carry their auto-injectors, and generally wanted to remain safe. Their decisions were complex, multi-faceted and highly individualised. Conclusions Rather than aiming for 100% carriage of auto-injectors, which remains an ambitious ideal, personalised education packages should aim to empower teenagers to make and act upon informed risk assessments. PMID:22409884
Assessment of Factors Related to Auto-PEEP.
Natalini, Giuseppe; Tuzzo, Daniele; Rosano, Antonio; Testa, Marco; Grazioli, Michele; Pennestrì, Vincenzo; Amodeo, Guido; Marsilia, Paolo F; Tinnirello, Andrea; Berruto, Francesco; Fiorillo, Marialinda; Filippini, Matteo; Peratoner, Alberto; Minelli, Cosetta; Bernardini, Achille
2016-02-01
Previous physiological studies have identified factors that are involved in auto-PEEP generation. In our study, we examined how much auto-PEEP is generated from factors that are involved in its development. One hundred eighty-six subjects undergoing controlled mechanical ventilation with persistent expiratory flow at the beginning of each inspiration were enrolled in the study. Volume-controlled continuous mandatory ventilation with PEEP of 0 cm H2O was applied while maintaining the ventilator setting as chosen by the attending physician. End-expiratory and end-inspiratory airway occlusion maneuvers were performed to calculate respiratory mechanics, and tidal flow limitation was assessed by a maneuver of manual compression of the abdomen. The variable with the strongest effect on auto-PEEP was flow limitation, which was associated with an increase of 2.4 cm H2O in auto-PEEP values. Moreover, auto-PEEP values were directly related to resistance of the respiratory system and body mass index and inversely related to expiratory time/time constant. Variables that were associated with the breathing pattern (tidal volume, frequency minute ventilation, and expiratory time) did not show any relationship with auto-PEEP values. The risk of auto-PEEP ≥5 cm H2O was increased by flow limitation (adjusted odds ratio 17; 95% CI: 6-56.2), expiratory time/time constant ratio <1.85 (12.6; 4.7-39.6), respiratory system resistance >15 cm H2O/L s (3; 1.3-6.9), age >65 y (2.8; 1.2-6.5), and body mass index >26 kg/m(2) (2.6; 1.1-6.1). Flow limitation, expiratory time/time constant, resistance of the respiratory system, and obesity are the most important variables that affect auto-PEEP values. Frequency expiratory time, tidal volume, and minute ventilation were not independently associated with auto-PEEP. Therapeutic strategies aimed at reducing auto-PEEP and its adverse effects should be primarily oriented to the variables that mainly affect auto-PEEP values. Copyright © 2016 by Daedalus Enterprises.
ERIC Educational Resources Information Center
McCormick, Alexandra
2017-01-01
In this article, I offer a reflexive auto-ethnography to revisit questions about knowledge and research practices in international contexts, influenced differently by aspects of globalization. Specifically, I position my experience of the Vanuatu research moratorium on "foreign" researchers of 2013/2014 as a lynchpin to analyse and…
Fault tolerant control of multivariable processes using auto-tuning PID controller.
Yu, Ding-Li; Chang, T K; Yu, Ding-Wen
2005-02-01
Fault tolerant control of dynamic processes is investigated in this paper using an auto-tuning PID controller. A fault tolerant control scheme is proposed composing an auto-tuning PID controller based on an adaptive neural network model. The model is trained online using the extended Kalman filter (EKF) algorithm to learn system post-fault dynamics. Based on this model, the PID controller adjusts its parameters to compensate the effects of the faults, so that the control performance is recovered from degradation. The auto-tuning algorithm for the PID controller is derived with the Lyapunov method and therefore, the model predicted tracking error is guaranteed to converge asymptotically. The method is applied to a simulated two-input two-output continuous stirred tank reactor (CSTR) with various faults, which demonstrate the applicability of the developed scheme to industrial processes.
Solovyev, M V; Mendeleeva, L P; Pokrovskaya, O S; Nareyko, M V; Firsova, M V; Galtseva, I V; Davydova, Yu O; Kapranov, N M; Kuzmina, L A; Gemdzhian, E G; Savchenko, V G
To determine the efficiency of maintenance therapy with bortezomib in patients with multiple myeloma (MM) who have achieved complete remission (CR) after autologous hematopoietic stem cell (auto-HSCT), depending on the presence of minimal residual disease (MRD). In January 2014 to February 2016, fifty-two MM patients (19 men and 33 women) aged 24 to 66 years (median 54 years), who had achieved CR after auto-HSCT, were randomized to perform maintenance therapy with bortezomib during a year. On day 100 after auto-HSCT, all the patients underwent immunophenotyping of bone marrow plasma cells by 6-color flow cytometry to detect MRD. Relapse-free survival (RFS) was chosen as a criterion for evaluating the efficiency of maintenance therapy. After auto-HSCT, MRD-negative patients had a statistically significantly higher 2-year RFS rate than MRD-positive patients: 52.9% (95% confidence interval (CI), 35.5 to 70.5%) versus 37.2% (95% CI, 25.4 to 49.3%) (p=0.05). The presence of MRD statistically significantly increased the risk of relapse (odds ratio 1.7; 95% CI, 1.2 to 3.4; p=0.05). Two-year cumulative risk of relapse (using the Kaplan-Meier) after auto-HSCT did not statistically significantly differ in MRD-negative patients receiving (n=15) and not receiving (n=10) maintenance therapy with bortezomib (p=0.58). After completion of maintenance treatment, 42% of the MRD-positive patients achieved a negative status. In the MRD-positive patients who had received maintenance therapy, the average time to recurrence was 5 months longer than that in the naïve patients: 17.3 versus 12.3 months. The MRD status determined in MM patients who have achieved CR after auto-HSCT is an important factor for deciding on the use of maintenance therapy.
The effectiveness of stationary automobiles as shelters in accidental releases of toxic materials
NASA Astrophysics Data System (ADS)
Engelmann, Rudolf J.; Pendergrass, William R.; White, J. Randy; Hall, Mark E.
The protection offered occupants of stationary automobiles against airborne gases and respirable particles, such as might result from an accidental release, was measured and found to be substantial. For the four autos tested with the air conditioning (AC) system on and in recirculate position, the equilibrium ratios of inside/outside concentrations ( I/ O) for 2-μm diameter particles were less than 0.2, and some ratios were as small as 0.014. With both the AC compressor and the system fan off, the I/ O for five autos ranged from 0.04 to 0.18. These low ratios are primarily a result of deposition within the autos. However, three of the five autos had substantially higher I/ O ratios when the AC fan was on than when off, indicating that for some autos the AC caused significant added intake of outside air. Air exchange rates for the five stationary autos were on the order of 0.5h -1 with AC off, and 2.5 h -1 with AC on.
Jang, Jinbeum; Yoo, Yoonjong; Kim, Jongheon; Paik, Joonki
2015-03-10
This paper presents a novel auto-focusing system based on a CMOS sensor containing pixels with different phases. Robust extraction of features in a severely defocused image is the fundamental problem of a phase-difference auto-focusing system. In order to solve this problem, a multi-resolution feature extraction algorithm is proposed. Given the extracted features, the proposed auto-focusing system can provide the ideal focusing position using phase correlation matching. The proposed auto-focusing (AF) algorithm consists of four steps: (i) acquisition of left and right images using AF points in the region-of-interest; (ii) feature extraction in the left image under low illumination and out-of-focus blur; (iii) the generation of two feature images using the phase difference between the left and right images; and (iv) estimation of the phase shifting vector using phase correlation matching. Since the proposed system accurately estimates the phase difference in the out-of-focus blurred image under low illumination, it can provide faster, more robust auto focusing than existing systems.
Jang, Jinbeum; Yoo, Yoonjong; Kim, Jongheon; Paik, Joonki
2015-01-01
This paper presents a novel auto-focusing system based on a CMOS sensor containing pixels with different phases. Robust extraction of features in a severely defocused image is the fundamental problem of a phase-difference auto-focusing system. In order to solve this problem, a multi-resolution feature extraction algorithm is proposed. Given the extracted features, the proposed auto-focusing system can provide the ideal focusing position using phase correlation matching. The proposed auto-focusing (AF) algorithm consists of four steps: (i) acquisition of left and right images using AF points in the region-of-interest; (ii) feature extraction in the left image under low illumination and out-of-focus blur; (iii) the generation of two feature images using the phase difference between the left and right images; and (iv) estimation of the phase shifting vector using phase correlation matching. Since the proposed system accurately estimates the phase difference in the out-of-focus blurred image under low illumination, it can provide faster, more robust auto focusing than existing systems. PMID:25763645
Marrone, Oreste; Cibella, Fabio; Pépin, Jean-Louis; Grote, Ludger; Verbraecken, Johan; Saaresranta, Tarja; Kvamme, John A; Basoglu, Ozen K; Lombardi, Carolina; McNicholas, Walter T; Hedner, Jan; Bonsignore, Maria R
2018-04-23
The impact of treating obstructive sleep apnea (OSA) on renal function decline is controversial. Previous studies usually included small samples and did not consider specific effects of different continuous positive airway pressure (CPAP) modalities. The aim of this study was to evaluate the respective influence of fixed and auto-adjusting CPAP modes on estimated glomerular filtration rate (eGFR) in a large sample of patients derived from the prospective European Sleep Apnea Database (ESADA) cohort. In patients of the ESADA, eGFR before and after follow-up was calculated using the CKD-EPI equation. Three study groups were investigated, namely untreated patients (n=144), patients receiving fixed continuous positive airway pressure (fCPAP) (n=1,178), and patients on auto-adjusting CPAP (APAP) (n=485). In the whole sample, eGFR decreased over time. The rate of eGFR decline was significantly higher in the subgroup with eGFR above median [91.42 ml/min/1.73m 2 ] at baseline (p<0.0001 for effect of baseline eGFR). This decline was attenuated or absent (p<0.0001 for effect of treatment) in the subgroup of OSA treated by fCPAP. A follow-up duration exceeding the median (541 days), was associated with eGFR decline in the untreated and APAP groups, but not in the fCPAP group (p <0.0001 by two-way ANOVA for interaction between treatment and follow-up length). In multiple regression analysis, eGFR decline was accentuated by advanced age, female gender, cardiac failure, higher baseline eGFR and longer follow-up duration, while there was a protective effect of fCPAP. Fixed CPAP but not APAP, may prevent eGFR decline in OSA. Copyright © 2018 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Rains, Larry
This engine performance (emission control systems) module is one of a series of competency-based modules in the Missouri Auto Mechanics Curriculum Guide. Topics of this module's five units are: positive crankcase ventilation (PCV) and evaporative emission control systems; exhaust gas recirculation (EGR); air injection and catalytic converters;…
Gilman, Andrew J; Le, An K; Zhao, Changqing; Hoang, Joseph; Yasukawa, Lee A; Weber, Susan C; Vierling, John M; Nguyen, Mindie H
2018-01-01
Goals To examine the role that autoantibodies (auto-abs) play in chronic hepatitis C virus (HCV) regarding demographics, presence of extrahepatic manifestations and long-term outcomes in a large US cohort. Background Auto-abs have been reported to be prevalent in patients with chronic HCV infection, but data on the natural history of these patients are limited. Study The study included 1556 consecutive patients with HCV without concurrent HIV and/or HBV who had testing for antinuclear antibody (ANA), antimitochondrial antibody (AMA), antismooth muscle antibody (ASMA) and/or antiliver kidney microsomal antibody (LKM). Primary outcomes included development of cirrhosis, hepatic decompensations, hepatocellular carcinoma (HCC), mortality and/or sustained virological response (SVR) to antiviral therapy. Results A total of 388 patients tested positive for any auto-ab (ANA 21.8%, ASMA 13.3%, AMA 2.2% and LKM 1.2%). Patients who tested positive versus negative were more likely to be women (29.3% vs 20.9%, p<0.001) and less likely to achieve SVR with most treated patients receiving interferon-based therapies (37.2% vs 47.1%, p=0.031). There was no difference between groups for baseline laboratory data, disease state or rate of extrahepatic manifestations (42.8% vs 45.0%, p=0.44). Kaplan-Meier analysis revealed no statistically significant difference between groups for the 10-year development of cirrhosis, hepatic decompensations, HCC nor survival. Furthermore, auto-ab positivity was only found to be a predictor for a lower rate of SVR on multivariate analysis (adjusted OR=1.61, 95 % CI 1.00 to 2.58, p=0.048). Conclusions In our cohort, auto-ab positivity was common, especially in women, and predicted a lower rate of SVR but otherwise had no impact on the natural history of chronic HCV or presence of extrahepatic manifestations. PMID:29755758
Jimenez-Zepeda, V H; Reece, D E; Trudel, S; Chen, C; Tiedemann, R; Kukreti, V
2015-02-01
The role of auto-SCT in the treatment of multiple myeloma (MM) in the era of novel agents continues to evolve. It is now clear that the depth of response and clinical outcomes have significantly improved as a result of the combination of these strategies. However, not all patients with MM who undergo auto-SCT are able to sustain a meaningful response and 20% of patients relapse shortly after auto-SCT. In this study, we aimed to assess the impact of early relapse (ER) after auto-SCT on OS for MM patients undergoing single auto-SCT who had received novel agent-based induction regimens. All consecutive patients with MM undergoing single auto-SCT from January 2002 to September 2012 who had novel induction therapy were evaluated. A total of 184 patients were identified. The median OS and PFS for the group of transplanted patients were 93 and 25.4 months, respectively. Median time to relapse was 17.2 months with 40% having relapsed at the time of analysis. ER (<12 months post auto-SCT) was seen in 27 (36%) out of 75 patients who had relapsed, and median OS was significantly shorter than in those with non-ER. Multivariate analysis showed ER as the major independent prognostic factor for OS. On the basis of these findings, we conclude that not only attainment of a good response, but sustainability of it, appears to be a major prognostic variable in MM in the era of novel therapy. Patients with ER post auto-SCT should biologically be characterized in prospective studies to better understand the mechanisms of resistance associated with this particular entity.
Nam, HyungSoo; Choi, ByungGil; Oh, Daegun
2018-01-01
In this paper, a three-dimensional (3D)-subspace-based azimuth angle, elevation angle, and range estimation method with auto-pairing is proposed for frequency-modulated continuous waveform (FMCW) radar with an L-shaped array. The proposed method is designed to exploit the 3D shift-invariant structure of the stacked Hankel snapshot matrix for auto-paired azimuth angle, elevation angle, and range estimation. The effectiveness of the proposed method is verified through a variety of experiments conducted in a chamber. For the realization of the proposed method, K-band FMCW radar is implemented with an L-shaped antenna. PMID:29621193
A visual LISP program for voxelizing AutoCAD solid models
NASA Astrophysics Data System (ADS)
Marschallinger, Robert; Jandrisevits, Carmen; Zobl, Fritz
2015-01-01
AutoCAD solid models are increasingly recognized in geological and geotechnical 3D modeling. In order to bridge the currently existing gap between AutoCAD solid models and the grid modeling realm, a Visual LISP program is presented that converts AutoCAD solid models into voxel arrays. Acad2Vox voxelizer works on a 3D-model that is made up of arbitrary non-overlapping 3D-solids. After definition of the target voxel array geometry, 3D-solids are scanned at grid positions and properties are streamed to an ASCII output file. Acad2Vox has a novel voxelization strategy that combines a hierarchical reduction of sampling dimensionality with an innovative use of AutoCAD-specific methods for a fast and memory-saving operation. Acad2Vox provides georeferenced, voxelized analogs of 3D design data that can act as regions-of-interest in later geostatistical modeling and simulation. The Supplement includes sample geological solid models with instructions for practical work with Acad2Vox.
Optimal design of a high accuracy photoelectric auto-collimator based on position sensitive detector
NASA Astrophysics Data System (ADS)
Yan, Pei-pei; Yang, Yong-qing; She, Wen-ji; Liu, Kai; Jiang, Kai; Duan, Jing; Shan, Qiusha
2018-02-01
A kind of high accuracy Photo-electric auto-collimator based on PSD was designed. The integral structure composed of light source, optical lens group, Position Sensitive Detector (PSD) sensor, and its hardware and software processing system constituted. Telephoto objective optical type is chosen during the designing process, which effectively reduces the length, weight and volume of the optical system, as well as develops simulation-based design and analysis of the auto-collimator optical system. The technical indicators of auto-collimator presented by this paper are: measuring resolution less than 0.05″; a field of view is 2ω=0.4° × 0.4° measuring range is +/-5' error of whole range measurement is less than 0.2″. Measuring distance is 10m, which are applicable to minor-angle precise measuring environment. Aberration analysis indicates that the MTF close to the diffraction limit, the spot in the spot diagram is much smaller than the Airy disk. The total length of the telephoto lens is only 450mm by the design of the optical machine structure optimization. The autocollimator's dimension get compact obviously under the condition of the image quality is guaranteed.
Space imaging infrared optical guidance for autonomous ground vehicle
NASA Astrophysics Data System (ADS)
Akiyama, Akira; Kobayashi, Nobuaki; Mutoh, Eiichiro; Kumagai, Hideo; Yamada, Hirofumi; Ishii, Hiromitsu
2008-08-01
We have developed the Space Imaging Infrared Optical Guidance for Autonomous Ground Vehicle based on the uncooled infrared camera and focusing technique to detect the objects to be evaded and to set the drive path. For this purpose we made servomotor drive system to control the focus function of the infrared camera lens. To determine the best focus position we use the auto focus image processing of Daubechies wavelet transform technique with 4 terms. From the determined best focus position we transformed it to the distance of the object. We made the aluminum frame ground vehicle to mount the auto focus infrared unit. Its size is 900mm long and 800mm wide. This vehicle mounted Ackerman front steering system and the rear motor drive system. To confirm the guidance ability of the Space Imaging Infrared Optical Guidance for Autonomous Ground Vehicle we had the experiments for the detection ability of the infrared auto focus unit to the actual car on the road and the roadside wall. As a result the auto focus image processing based on the Daubechies wavelet transform technique detects the best focus image clearly and give the depth of the object from the infrared camera unit.
Karasulu, Levent; Epöztürk, Pinar Ozkan; Sökücü, Sinem Nedime; Dalar, Levent; Altin, Sedat
2010-08-01
The effect of positive airway pressure treatments in different modalities on the cardiovascular consequences of the disease in sleep apnea patients is still unclear. We aimed to compare auto-titrating positive airway pressure (APAP) and conventional continuous positive airway pressure (CPAP) in terms of improving heart rate variability (HRV) in obstructive sleep apnea patients. This was a prospective study done in a tertiary research hospital. All patients underwent a manual CPAP titration procedure to determine the optimal pressure that abolishes abnormal respiratory events. Then patients underwent two treatment nights, one under APAP mode and one under conventional CPAP mode with a 1-week interval. Forty newly diagnosed obstructive sleep apnea patients were enrolled in the study. We compared heart rate variability analysis parameters between the APAP night and the CPAP night. This final analysis included the data of 28 patients (M/F: 22/6; mean age = 46 +/- 10 years). Sleep characteristics were comparable between the two treatment nights, whereas all-night time domains of HRV analysis such as HF, nuLF, and LF/HF were different between APAP and CPAP nights (2.93 +/- 0.31 vs. 3.01 +/- 0.31; P = 0.041; 0.75 +/- 0.13 vs. 0.71 +/- 0.14; P = 0.027; and 4.37 +/- 3.24 vs. 3.56 +/- 2.07; P = 0.023, respectively). HRV analysis for individual sleep stages showed that Stage 2 LF, nuLF, nuHF, LF/HF parameters entirely improved under CPAP treatment whereas APAP treatment resulted in nonsignificant changes. These results suggest that despite comparable improvement in abnormal respiratory events with APAP or CPAP treatments, CPAP may be superior to APAP in terms of correcting cardiovascular alterations in sleep apnea patients.
Cha, Dong Ik; Lee, Min Woo; Song, Kyoung Doo; Oh, Young-Taek; Jeong, Ja-Yeon; Chang, Jung-Woo; Ryu, Jiwon; Lee, Kyong Joon; Kim, Jaeil; Bang, Won-Chul; Shin, Dong Kuk; Choi, Sung Jin; Koh, Dalkwon; Seo, Bong Koo; Kim, Kyunga
2017-06-01
To compare the accuracy and required time for image fusion of real-time ultrasound (US) with pre-procedural magnetic resonance (MR) images between positioning auto-registration and manual registration for percutaneous radiofrequency ablation or biopsy of hepatic lesions. This prospective study was approved by the institutional review board, and all patients gave written informed consent. Twenty-two patients (male/female, n = 18/n = 4; age, 61.0 ± 7.7 years) who were referred for planning US to assess the feasibility of radiofrequency ablation (n = 21) or biopsy (n = 1) for focal hepatic lesions were included. One experienced radiologist performed the two types of image fusion methods in each patient. The performance of auto-registration and manual registration was evaluated. The accuracy of the two methods, based on measuring registration error, and the time required for image fusion for both methods were recorded using in-house software and respectively compared using the Wilcoxon signed rank test. Image fusion was successful in all patients. The registration error was not significantly different between the two methods (auto-registration: median, 3.75 mm; range, 1.0-15.8 mm vs. manual registration: median, 2.95 mm; range, 1.2-12.5 mm, p = 0.242). The time required for image fusion was significantly shorter with auto-registration than with manual registration (median, 28.5 s; range, 18-47 s, vs. median, 36.5 s; range, 14-105 s, p = 0.026). Positioning auto-registration showed promising results compared with manual registration, with similar accuracy and even shorter registration time.
Double-lumen tubes and auto-PEEP during one-lung ventilation.
Spaeth, J; Ott, M; Karzai, W; Grimm, A; Wirth, S; Schumann, S; Loop, T
2016-01-01
Double-lumen tubes (DLT) are routinely used to enable one-lung-ventilation (OLV) during thoracic anaesthesia. The flow-dependent resistance of the DLT's bronchial limb may be high as a result of its narrow inner diameter and length, and thus potentially contribute to an unintended increase in positive end-expiratory pressure (auto-PEEP). We therefore studied the impact of adult sized DLTs on the dynamic auto-PEEP during OLV. In this prospective clinical study, dynamic auto-PEEP was determined in 72 patients undergoing thoracic surgery, with right- and left-sided DLTs of various sizes. During OLV, air trapping was provoked by increasing inspiration to expiration ratio from 1:2 to 2:1 (five steps). Based on measured flow rate, airway pressure (Paw) and bronchial pressure (Pbronch), the pressure gradient across the DLT (ΔPDLT) and the total auto-PEEP in the respiratory system (i.e. the lungs, the DLT and the ventilator circuit) were determined. Subsequently the DLT's share in total auto-PEEP was calculated. ΔPDLT was 2.3 (0.7) cm H2O over the entire breathing cycle. At the shortest expiratory time the mean total auto-PEEP was 2.9 (1.5) cm H2O (range 0-5.9 cm H2O). The DLT caused 27 to 31% of the total auto-PEEP. Size and side of the DLT's bronchial limb did not impact auto-PEEP significantly. Although the DLT contributes to the overall auto-PEEP, its contribution is small and independent of size and side of the DLT's bronchial limb. The choice of DLT does not influence the risk of auto-PEEP during OLV to a clinically relevant extent. DRKS00005648. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Face detection assisted auto exposure: supporting evidence from a psychophysical study
NASA Astrophysics Data System (ADS)
Jin, Elaine W.; Lin, Sheng; Dharumalingam, Dhandapani
2010-01-01
Face detection has been implemented in many digital still cameras and camera phones with the promise of enhancing existing camera functions (e.g. auto exposure) and adding new features to cameras (e.g. blink detection). In this study we examined the use of face detection algorithms in assisting auto exposure (AE). The set of 706 images, used in this study, was captured using Canon Digital Single Lens Reflex cameras and subsequently processed with an image processing pipeline. A psychophysical study was performed to obtain optimal exposure along with the upper and lower bounds of exposure for all 706 images. Three methods of marking faces were utilized: manual marking, face detection algorithm A (FD-A), and face detection algorithm B (FD-B). The manual marking method found 751 faces in 426 images, which served as the ground-truth for face regions of interest. The remaining images do not have any faces or the faces are too small to be considered detectable. The two face detection algorithms are different in resource requirements and in performance. FD-A uses less memory and gate counts compared to FD-B, but FD-B detects more faces and has less false positives. A face detection assisted auto exposure algorithm was developed and tested against the evaluation results from the psychophysical study. The AE test results showed noticeable improvement when faces were detected and used in auto exposure. However, the presence of false positives would negatively impact the added benefit.
Autonomous GN and C for Spacecraft Exploration of Comets and Asteroids
NASA Technical Reports Server (NTRS)
Carson, John M.; Mastrodemos, Nickolaos; Myers, David M.; Acikmese, Behcet; Blackmore, James C.; Moussalis, Dhemetrio; Riedel, Joseph E.; Nolet, Simon; Chang, Johnny T.; Mandic, Milan;
2010-01-01
A spacecraft guidance, navigation, and control (GN&C) system is needed to enable a spacecraft to descend to a surface, take a sample using a touch-and-go (TAG) sampling approach, and then safely ascend. At the time of this reporting, a flyable GN&C system that can accomplish these goals is beyond state of the art. This article describes AutoGNC, which is a GN&C system capable of addressing these goals, which has recently been developed and demonstrated to a maturity TRL-5-plus. The AutoGNC solution matures and integrates two previously existing JPL capabilities into a single unified GN&C system. The two capabilities are AutoNAV and GREX. AutoNAV is JPL s current flight navigation system, and is fairly mature with respect to flybys and rendezvous with small bodies, but is lacking capability for close surface proximity operations, sampling, and contact. G-REX is a suite of low-TRL algorithms and capabilities that enables spacecraft operations in close surface proximity and for performing sampling/contact. The development and integration of AutoNAV and G-REX components into AutoGNC provides a single, unified GN&C capability for addressing the autonomy, close-proximity, and sampling/contact aspects of small-body sample return missions. AutoGNC is an integrated capability comprising elements that were developed separately. The main algorithms and component capabilities that have been matured and integrated are autonomy for near-surface operations, terrain-relative navigation (TRN), real-time image-based feedback guidance and control, and six degrees of freedom (6DOF) control of the TAG sampling event. Autonomy is achieved based on an AutoGNC Executive written in Virtual Machine Language (VML) incorporating high-level control, data management, and fault protection. In descending to the surface, the AutoGNC system uses camera images to determine its position and velocity relative to the terrain. This capability for TRN leverages native capabilities of the original AutoNAV system, but required advancements that integrate the separate capabilities for shape modeling, state estimation, image rendering, defining a database of onboard maps, and performing real-time landmark recognition against the stored maps. The ability to use images to guide the spacecraft requires the capability for image-based feedback control. In Auto- GNC, navigation estimates are fed into an onboard guidance and control system that keeps the spacecraft guided along a desired path, as it descends towards its targeted landing or sampling site. Once near the site, AutoGNC achieves a prescribed guidance condition for TAG sampling (position/orientation, velocity), and a prescribed force profile on the sampling end-effector. A dedicated 6DOF TAG control then implements the ascent burn while recovering from sampling disturbances and induced attitude rates. The control also minimizes structural interactions with flexible solar panels and disallows any part of the spacecraft from making contact with the ground (other than the intended end-effector).
Immunological consequences of vasectomy.
Shahani, S K; Hattikudur, N S
1981-09-01
In more than 50% of men, vasectomy leads to auto-immune pathology. The auto-immune response to sperms following vasectomy is triggered by the phagocytosis of sperm in the epididymis. In the humoral immune response, sperm agglutinating, sperm immobilizing, and antibodies to sperm nuclear protamines occur, as early as 3-4 days after vasectomy. The incidence reaches 60-70% within 1 year and remains almost the same even after 20 years. Presence and effects of circulating immune complexes following vasectomy are discussed with reference to reported increased incidence of atherosclerosis and auto-immune orchitis in experimental animals. There is no positive conclusion whether vasectomy leads to cell mediated immunity to spermatozoa.
Chuang, Ho-Chiao; Hsu, Hsiao-Yu; Nieh, Shu-Kan; Tien, Der-Chi
2015-01-01
The purpose of this study is to assess the feasibility of using the analytical technique of ultrasound images in combination with an auto tumor localization system. During respiration, the activity of breathing in and out causes organs displacement at the lower lobe of the lung, and the maximum displacement range happens in the Superior-Inferior (SI) direction. Therefore, in this study all the tumor positioning is in SI direction under respiratory compensation, in which the compensations are carried out to the organs at the lower lobe and adjacent to the lower lobe of lung.In this research, due to the processes of ultrasound imaging generation, image analysis and signal transmission, when the captured respiratory signals are sent to auto tumor localization system, there was a signal time delay. The total delay time of the entire signal transmission process was 0.254 ± 0.023 seconds (with the lowest standard deviation) after implementing a series of analyses. To compensate for this signal delay time (0.254 ± 0.023 sec), a phase lead compensator (PLC) was designed and built into the auto tumor localization system. By analyzing the impact of the delay time and the respiratory waveforms under different frequencies on the phase lead compensator, an overall system delay time can be configured. Results showed as the respiratory frequency increased, variable value ``a'' and the subsequent gain ``k'' in the controller becomes larger. Moreover, value ``a'' and ``k'' increased as the system delay time increased when the respiratory frequency was fixed. The relationship of value ``a'' and ``k'' to the respiratory frequency can be obtained by using the curve fitting method to compensate for the respiratory motion for tumor localization. Through the comparison of the uncompensated signal and the compensated signal performed by the auto tumor localization system on the simulated respiratory signal, the feasibility of using ultrasound image analysis technology combined with the developed auto tumor localization system can be evaluated. The results show that the simulated respiratory signals under different frequencies of 0.5, 0.333, 0.25, 0.2 and 0.167 Hz with phase lead compensators were improved and stabilized. The compensation rate increased to the range of 7.04$∼ $18.82%, and the final compensation rate is about 97%. Therefore the auto tumor localization system combined with the ultrasound image analysis techniques is feasible.In this study, the developed ultrasound image analysis techniques combined into the auto tumor localization system has the following four advantages: (1) It is a non-invasive way (ultrasonic images) to monitor the entire compensating process of the active respiration instead of using a C-arm (invasive) to observe the organs motion. (2) During radiation therapy, the whole treatment process can be continuous, which can save the overall treatment time. (3) It is an independent system, which can be mounted onto any treatment couch. (4) Users can operate this system easily without the need of prior complicated training process.
Rahmouni, Hind W; Ky, Bonnie; Plappert, Ted; Duffy, Kevin; Wiegers, Susan E; Ferrari, Victor A; Keane, Martin G; Kirkpatrick, James N; Silvestry, Frank E; St John Sutton, Martin
2008-03-01
Ejection fraction (EF) calculated from 2-dimensional echocardiography provides important prognostic and therapeutic information in patients with heart disease. However, quantification of EF requires planimetry and is time-consuming. As a result, visual assessment is frequently used but is subjective and requires extensive experience. New computer software to assess EF automatically is now available and could be used routinely in busy digital laboratories (>15,000 studies per year) and in core laboratories running large clinical trials. We tested Siemens AutoEF software (Siemens Medical Solutions, Erlangen, Germany) to determine whether it correlated with visual estimates of EF, manual planimetry, and cardiac magnetic resonance (CMR). Siemens AutoEF is based on learned patterns and artificial intelligence. An expert and a novice reader assessed EF visually by reviewing transthoracic echocardiograms from consecutive patients. An experienced sonographer quantified EF in all studies using Simpson's method of disks. AutoEF results were compared to CMR. Ninety-two echocardiograms were analyzed. Visual assessment by the expert (R = 0.86) and the novice reader (R = 0.80) correlated more closely with manual planimetry using Simpson's method than did AutoEF (R = 0.64). The correlation between AutoEF and CMR was 0.63, 0.28, and 0.51 for EF, end-diastolic and end-systolic volumes, respectively. The discrepancies in EF estimates between AutoEF and manual tracing using Simpson's method and between AutoEF and CMR preclude routine clinical use of AutoEF until it has been validated in a number of large, busy echocardiographic laboratories. Visual assessment of EF, with its strong correlation with quantitative EF, underscores its continued clinical utility.
Anti-D auto-immunization in a patient with weak D type 4.0.
Ouchari, M; Chakroun, T; Abdelkefi, S; Romdhane, H; Houissa, B; Jemni Yacoub, S
2014-03-01
We report the case of a 56-year-old patient with blood group O+C-c+E-e+K-, followed for a myelodysplasic syndrome and treated by regular pheno-identical and compatible (RBCs) transfusion since December 2007. In June 2009, a positive crossmatch was found with 2 RBCs O+C-c+E-e+K-. A positive anti-body screening with a positive autocontrol was detected and anti-D was unidentified in the patient's serum. The DAT was positive (IgG) and elution identified an anti-D. The following assumptions were then made: it could be a partial D phenotype with anti-D alloantibodies or RH: 1 phenotype with an anti-D auto-antibodies. Molecular analysis by multiplex PCR and sequencing have depisted a weak D type 4.0 phenotype. In October 2009, over three months of RH:-1 RBC transfusion, the antibody screening and DAT (IgG) remained positive, and an eluate made from the patient's erythrocytes contained an anti-D. All these funding confirmed the autoimmune nature of the anti-D. This case report illustrates the importance of a well-conducted and immunohematological laboratories test in order to distinguish between auto- or allo-immune of anti-D in a RH: 1 poly-transfused patients. This distinction is of great importance for transfusion support. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
[Value of positive auto controls in the gel centrifugation method].
Eichler, H; Kretschmer, V
1994-01-01
We studied 97 samples of patients being positive in the autocontrol of the indirect antiglobulin test (IAT) in the gel system (DiaMed). In 83.2%, retesting with monospecific anti-IgG serum gave also positive results, due to a specific phenomenon caused, for example, by drug-specific antibodies (AB), warm auto-AB or allo-AB. In contrast, only 52.9% of the samples retested by the standard tube technique with polyspecific antiglobulin serum reacted positive. Only in 6 patients slightly increased cold agglutinins could be detected. None of the investigated patients showed any clinical or laboratory signs of hemolysis except one with pernicious anemia. We conclude that positive results of the autocontrol in the gel IAT should be confirmed by an additional DAT in the tube technique. If this second test shows a negative result, transfusions can take place without any restrictions.
Retrofitting the AutoBayes Program Synthesis System with Concrete Syntax
NASA Technical Reports Server (NTRS)
Fischer, Bernd; Visser, Eelco
2004-01-01
AutoBayes is a fully automatic, schema-based program synthesis system for statistical data analysis applications. Its core component is a schema library. i.e., a collection of generic code templates with associated applicability constraints which are instantiated in a problem-specific way during synthesis. Currently, AutoBayes is implemented in Prolog; the schemas thus use abstract syntax (i.e., Prolog terms) to formulate the templates. However, the conceptual distance between this abstract representation and the concrete syntax of the generated programs makes the schemas hard to create and maintain. In this paper we describe how AutoBayes is retrofitted with concrete syntax. We show how it is integrated into Prolog and describe how the seamless interaction of concrete syntax fragments with AutoBayes's remaining legacy meta-programming kernel based on abstract syntax is achieved. We apply the approach to gradually mitigate individual schemas without forcing a disruptive migration of the entire system to a different First experiences show that a smooth migration can be achieved. Moreover, it can result in a considerable reduction of the code size and improved readability of the code. In particular, abstracting out fresh-variable generation and second-order term construction allows the formulation of larger continuous fragments.
Analysis of Air Traffic Track Data with the AutoBayes Synthesis System
NASA Technical Reports Server (NTRS)
Schumann, Johann Martin Philip; Cate, Karen; Lee, Alan G.
2010-01-01
The Next Generation Air Traffic System (NGATS) is aiming to provide substantial computer support for the air traffic controllers. Algorithms for the accurate prediction of aircraft movements are of central importance for such software systems but trajectory prediction has to work reliably in the presence of unknown parameters and uncertainties. We are using the AutoBayes program synthesis system to generate customized data analysis algorithms that process large sets of aircraft radar track data in order to estimate parameters and uncertainties. In this paper, we present, how the tasks of finding structure in track data, estimation of important parameters in climb trajectories, and the detection of continuous descent approaches can be accomplished with compact task-specific AutoBayes specifications. We present an overview of the AutoBayes architecture and describe, how its schema-based approach generates customized analysis algorithms, documented C/C++ code, and detailed mathematical derivations. Results of experiments with actual air traffic control data are discussed.
jMetalCpp: optimizing molecular docking problems with a C++ metaheuristic framework.
López-Camacho, Esteban; García Godoy, María Jesús; Nebro, Antonio J; Aldana-Montes, José F
2014-02-01
Molecular docking is a method for structure-based drug design and structural molecular biology, which attempts to predict the position and orientation of a small molecule (ligand) in relation to a protein (receptor) to produce a stable complex with a minimum binding energy. One of the most widely used software packages for this purpose is AutoDock, which incorporates three metaheuristic techniques. We propose the integration of AutoDock with jMetalCpp, an optimization framework, thereby providing both single- and multi-objective algorithms that can be used to effectively solve docking problems. The resulting combination of AutoDock + jMetalCpp allows users of the former to easily use the metaheuristics provided by the latter. In this way, biologists have at their disposal a richer set of optimization techniques than those already provided in AutoDock. Moreover, designers of metaheuristic techniques can use molecular docking for case studies, which can lead to more efficient algorithms oriented to solving the target problems. jMetalCpp software adapted to AutoDock is freely available as a C++ source code at http://khaos.uma.es/AutodockjMetal/.
Pontes, E R; Matos, L C; da Silva, E A; Xavier, L S; Diaz, B L; Small, I A; Reis, E M; Verjovski-Almeida, S; Barcinski, M A; Gimba, E R P
2006-10-01
Here we evaluate auto-antibody response against two potential antigenic determinants of genes highly expressed in low Gleason Score prostate cancer (PC) tumor samples, namely FLJ23438 and VAMP3. RT-PCR assays were used to analyze mRNA expression profiles of FLJ23438 and VAMP3 transcripts. The auto-antibody response against FLJ23438 and VAMP3 recombinant proteins was tested by immunoblot assays using PC, benign prostate hyperplasia (BPH), healthy donors (HD), and other human cancers plasma samples. Our data showed that 37% (10/27) and 7.4% (2/27) of PC plasma samples presented auto-antibodies against FLJ23438 and VAMP3, respectively. Only 8.3% (1/12) of BPH plasma samples were reactive for both auto-antibodies, while none (0/12) of HD plasma samples tested were reactive. The prevalence of 37% of positive PC plasma samples for anti-FLJ23438 antibodies suggests that humoral immune response against this antigenic determinant could be a potential serum marker for this cancer. (c) 2006 Wiley-Liss, Inc.
Autonomous Formation Flying from Ground to Flight
NASA Technical Reports Server (NTRS)
Chapman, Keith B.; Dell, Gregory T.; Rosenberg, Duane L.; Bristow, John
1999-01-01
The cost of on-orbit operations remains a significant and increasingly visible concern in the support of satellite missions. Headway has been made in automating some ground operations; however, increased mission complexity and more precise orbital constraints have compelled continuing human involvement in mission design and maneuver planning operations. AI Solutions, Inc. in cooperation with the National Aeronautics and Space Administration's (NASA) Goddard Space Flight Center (GSFC) has tackled these more complex problems through the development of AutoCon as a tool for an automated solution. NASA is using AutoCon to automate the maneuver planning for the Earth Orbiter-1 (EO-1) mission. AutoCon was developed originally as a ground system tool. The EO-1 mission will be using a scaled version of AutoCon on-board the EO-1 satellite to command orbit adjustment maneuvers. The flight version of AutoCon plans maneuvers based on formation flying algorithms developed by GSFC, JPL, and other industry partners. In its fully autonomous mode, an AutoCon planned maneuver will be executed on-board the satellite without intervention from the ground. This paper describes how AutoCon automates maneuver planning for the formation flying constraints of the EO-1 mission. AutoCon was modified in a number of ways to automate the maneuver planning on-board the satellite. This paper describes how the interface and functionality of AutoCon were modified to support the on-board system. A significant component of this modification was the implementation of a data smoother, based on a Kalman filter, that ensures that the spacecraft states estimated by an on-board GPS receiver are as accurate as possible for maneuver planning. This paper also presents the methodology use to scale the AutoCon functionality to fit and execute on the flight hardware. This paper also presents the modes built that allow the incremental phasing in of autonomy. New technologies for autonomous operations are usually received with significant, and probably appropriate trepidation. A number of safeguards have been designed in both AutoCon and the interfacing systems to alleviate the potential of mission-impacting anomalies from the on-board autonomous system. This paper describes the error checking, input data integrity validation and limits set on maneuvers in AutoCon and the on-board system.
Autonomous Formation Flying from the Ground to Flight
NASA Technical Reports Server (NTRS)
Chapman, Keith B.; Dell, Gregory T.; Rosenberg, Duane L.; Bristow, John
1999-01-01
The cost of on-orbit operations remains a significant and increasingly visible concern in the support of satellite missions. Headway has been made in automating some ground operations; however, increased mission complexity and more precise orbital constraints have compelled continuing human involvement in mission design and maneuver planning operations. AI Solutions, Inc. in cooperation with the National Aeronautics and Space Administration's (NASA) Goddard Space Flight Center (GSFC) has tackled these more complex problems through the development of AutoCon(TM) as a tool for an automated solution. NASA is using AutoCon(TM) to automate the maneuver planning for the Earth Orbiter-1 (EO-1) mission. AutoCon(TM) was developed originally as a ground system tool. The EO-1 mission will be using a scaled version of AutoCon(TM) on-board the EO-1 satellite to command orbit adjustment maneuvers. The flight version of AutoCon(TM) plans maneuvers based on formation flying algorithms developed by GSFC, JPL, and other industry partners. In its fully autonomous mode, an AutoCon(TM) planned maneuver will be executed on-board the satellite without intervention from the ground. This paper describes how AutoCon(TM) automates maneuver planning for the formation flying constraints of the EO-1 mission. AutoCon(TM) was modified in a number of ways to automate the maneuver planning on-board the satellite. This paper describes how the interface and functionality of AutoCon(TM) were modified to support the on-board system. A significant component of this modification was the implementation of a data smoother, based on a Kalman filter, that ensures that the spacecraft states estimated by an on-board GPS receiver are as accurate as possible for maneuver planning. This paper also presents the methodology used to scale the AutoCon(TM) functionality to fit and execute on the flight hardware. This paper also presents the modes built into the system that allow the incremental phasing in of autonomy. New technologies for autonomous operations are usually received with significant, and probably appropriate, trepidation. A number of safeguards have been designed in both AutoCon(TM) and the interfacing systems to alleviate the potential of mission-impacting anomalies from the on-board autonomous system. This paper describes the error checking, input data integrity validation, and limits set on maneuvers in AutoCon(TM) and the on-board system.
Rapid automated method for screening of enteric pathogens from stool specimens.
Villasante, P A; Agulla, A; Merino, F J; Pérez, T; Ladrón de Guevara, C; Velasco, A C
1987-01-01
A total of 800 colonies suggestive of Salmonella, Shigella, or Yersinia species isolated on stool differential agar media were inoculated onto both conventional biochemical test media (triple sugar iron agar, urea agar, and phenylalanine agar) and Entero Pathogen Screen cards of the AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.). Based on the conventional tests, the AutoMicrobic system method yielded the following results: 587 true-negatives, 185 true-positives, 2 false-negatives, and 26 false-positives (sensitivity, 99%; specificity, 96%). Both true-positive and true-negative results were achieved considerably earlier than false results (P less than 0.001). The Entero Pathogen Screen card method is a fast, easy, and sensitive method for screening for Salmonella, Shigella, or Yersinia species. The impossibility of screening for oxidase-positive pathogens is a minor disadvantage of this method. PMID:3553230
Sajedi, Vahid; Movahedi, Masoud; Aghamohammadi, Asghar; Aghamohamadi, Asghar; Gharagozlou, Mohammad; Ghareguzlou, Mohammad; Shafiei, Alireza; Soheili, Habib; Sanajian, Nahal
2011-06-01
Intradermal injection of autologous serum and plasma elicit a cutaneous reactivity in almost 45-60% of patients with Chronic Idiopathic Urticaria (CIU). This reactivity is associated with the presence of auto antibodies against IgE or IgE receptors. This study was carried out to compare the cutaneous reactivity of autologous serum and plasma skin tests in a series of patients with CIU for diagnosis of auto antibodies against IgE or IgE receptor. Fifty eight patients with CIU were injected intradermally with autologous serum and plasma (anticoagulated by citrate). Histamine was used as positive control and normal saline as negative control. The study group was checked by routine laboratory tests (CBC, U/A etc), allergens with skin prick tests, and serum IgE level, and auto antibodies against thyroid as well. Duration of urticaria was another factor which was assessed.There was no significant difference between positive ASST and positive APST patients for the above mentioned tests. 77.6% of the patients were Positive for APST and 65.5% were ASST positive. Duration of urticaria was longer in patients with positive ASST and APST than ASST and APST negative patients, although the difference was not statistically significant.Autologus serum skin test (ASST) and autologous plasma skin test (APST) could be used for estimation of duration and severity of urticaria and planning for the treatment.
Simulation to coating weight control for galvanizing
NASA Astrophysics Data System (ADS)
Wang, Junsheng; Yan, Zhang; Wu, Kunkui; Song, Lei
2013-05-01
Zinc coating weight control is one of the most critical issues for continuous galvanizing line. The process has the characteristic of variable-time large time delay, nonlinear, multivariable. It can result in seriously coating weight error and non-uniform coating. We develop a control system, which can automatically control the air knives pressure and its position to give a constant and uniform zinc coating, in accordance with customer-order specification through an auto-adaptive empirical model-based feed forward adaptive controller, and two model-free adaptive feedback controllers . The proposed models with controller were applied to continuous galvanizing line (CGL) at Angang Steel Works. By the production results, the precise and stability of the control model reduces over-coating weight and improves coating uniform. The product for this hot dip galvanizing line does not only satisfy the customers' quality requirement but also save the zinc consumption.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-05
..., supplies a service (sales and service of Pontiac automobiles)'' and ``A required minimum of the workforce... foreign-made automobiles has increased continually for years, contributing importantly to an actual... was based on the continued production of Pontiac automobiles, therefore the increases of imported cars...
Moon, Kyoung-Ja; Jin, Yinji; Jin, Taixian; Lee, Sun-Mi
2018-01-01
A key component of the delirium management is prevention and early detection. To develop an automated delirium risk assessment system (Auto-DelRAS) that automatically alerts health care providers of an intensive care unit (ICU) patient's delirium risk based only on data collected in an electronic health record (EHR) system, and to evaluate the clinical validity of this system. Cohort and system development designs were used. Medical and surgical ICUs in two university hospitals in Seoul, Korea. A total of 3284 patients for the development of Auto-DelRAS, 325 for external validation, 694 for validation after clinical applications. The 4211 data items were extracted from the EHR system and delirium was measured using CAM-ICU (Confusion Assessment Method for Intensive Care Unit). The potential predictors were selected and a logistic regression model was established to create a delirium risk scoring algorithm to construct the Auto-DelRAS. The Auto-DelRAS was evaluated at three months and one year after its application to clinical practice to establish the predictive validity of the system. Eleven predictors were finally included in the logistic regression model. The results of the Auto-DelRAS risk assessment were shown as high/moderate/low risk on a Kardex screen. The predictive validity, analyzed after the clinical application of Auto-DelRAS after one year, showed a sensitivity of 0.88, specificity of 0.72, positive predictive value of 0.53, negative predictive value of 0.94, and a Youden index of 0.59. A relatively high level of predictive validity was maintained with the Auto-DelRAS system, even one year after it was applied to clinical practice. Copyright © 2017. Published by Elsevier Ltd.
When should we perform a repeat training on adrenaline auto-injector use for physician trainees?
Topal, E; Bakirtas, A; Yilmaz, O; Karagol, I H E; Arga, M; Demirsoy, M S; Turktas, I
2014-01-01
Studies demonstrate that both doctors and patients may use adrenaline auto-injector improperly and the usage skills are improved by training. In this study, we aimed to determine the appropriate frequency of training to maintain skills for adrenaline auto-injector use. We invited all interns of 2011-2012 training period. At baseline, all participants were given theoretical and practical training on adrenaline auto-injector use. The participants were randomly assigned into two groups. We asked those in group 1 to demonstrate the use of adrenaline auto-injector trainer in the third month and those in group 2 in the sixth month. One hundred and sixty interns were enrolled. Compared with the beginning score, demonstration of skills at all the steps and total scores did not change for the group tested in the third month (p=0.265 and p=0.888, respectively). However; for the group examined in the sixth month; the demonstration of skills for proper use of the auto-injector at all steps and the mean time to administer adrenaline decreased (p=0.018 and p<0.001, respectively). Besides, the group which was tested in the third month was better than the group which was tested in the sixth month in terms of demonstrating all steps (p=0.014), the total score (p=0.019), mean time of change to administer adrenaline (p<0.001) and presumptive self-injection into thumb (p=0.029). Auto-injector usage skills of physician trainees decrease after the sixth month and are better in those who had skill reinforcement at 3 months, suggesting continued education and skill reinforcement may be useful. Copyright © 2013 SEICAP. Published by Elsevier Espana. All rights reserved.
Onset of nonlinearity in a stochastic model for auto-chemotactic advancing epithelia
NASA Astrophysics Data System (ADS)
Ben Amar, Martine; Bianca, Carlo
2016-09-01
We investigate the role of auto-chemotaxis in the growth and motility of an epithelium advancing on a solid substrate. In this process, cells create their own chemoattractant allowing communications among neighbours, thus leading to a signaling pathway. As known, chemotaxis provokes the onset of cellular density gradients and spatial inhomogeneities mostly at the front, a phenomenon able to predict some features revealed in in vitro experiments. A continuous model is proposed where the coupling between the cellular proliferation, the friction on the substrate and chemotaxis is investigated. According to our results, the friction and proliferation stabilize the front whereas auto-chemotaxis is a factor of destabilization. This antagonist role induces a fingering pattern with a selected wavenumber k0. However, in the planar front case, the translational invariance of the experimental set-up gives also a mode at k = 0 and the coupling between these two modes in the nonlinear regime is responsible for the onset of a Hopf-bifurcation. The time-dependent oscillations of patterns observed experimentally can be predicted simply in this continuous non-linear approach. Finally the effects of noise are also investigated below the instability threshold.
Hand dermatitis in auto mechanics and machinists.
Donovan, Jeffrey C H; Kudla, Irena; Holness, D Linn
2007-09-01
Auto mechanics and machinists presenting with suspected allergic contact dermatitis (ACD) have traditionally been patch-tested with a standard screening tray and a specialty tray such as the Oil and Cooling Fluid Series. While this has proven useful for patch-testing the machinist, there is a need for the development of a more specific allergen testing tray for the auto mechanic. The objective of the study was to compare clinical features and patch-test results of auto mechanics and machinists with hand dermatitis to evaluate differences in allergen profiles. We performed a chart review of 33 auto mechanics and 24 machinists referred to our Occupational Contact Dermatitis Clinic from 2002 to 2005 for evaluation of hand dermatitis. With a panel of 84 allergens, 52 positive reactions were detected in 17 cases of ACD in mechanics. The profiles were different from the cases of ACD diagnosed in 10 of 24 machinists. Mechanics and machinists differ in the spectrum of occupational exposures. Patch testing with greater numbers of allergens likely identifies a larger proportion of mechanics with occupationally relevant ACD. Further study is needed to determine the most appropriate allergens to include in a clinically useful "mechanic's tray."
Effect of polarization and focusing on laser pulse driven auto-resonant particle acceleration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sagar, Vikram; Sengupta, Sudip; Kaw, Predhiman
2014-04-15
The effect of laser polarization and focusing is theoretically studied on the final energy gain of a particle in the Auto-resonant acceleration scheme using a finite duration laser pulse with Gaussian shaped temporal envelope. The exact expressions for dynamical variables viz. position, momentum, and energy are obtained by analytically solving the relativistic equation of motion describing particle dynamics in the combined field of an elliptically polarized finite duration pulse and homogeneous static axial magnetic field. From the solutions, it is shown that for a given set of laser parameters viz. intensity and pulse length along with static magnetic field, themore » energy gain by a positively charged particle is maximum for a right circularly polarized laser pulse. Further, a new scheme is proposed for particle acceleration by subjecting it to the combined field of a focused finite duration laser pulse and static axial magnetic field. In this scheme, the particle is initially accelerated by the focused laser field, which drives the non-resonant particle to second stage of acceleration by cyclotron Auto-resonance. The new scheme is found to be efficient over two individual schemes, i.e., auto-resonant acceleration and direct acceleration by focused laser field, as significant particle acceleration can be achieved at one order lesser values of static axial magnetic field and laser intensity.« less
Ter Borg, Evert-Jan; Kelder, Johannes Cornelis
2017-07-01
To test the hypothesis that systemic auto-antibodies or hypergammaglobulinemia are related to the prevalence of extra-glandular tissue organ damage (EGOD) in primary Sjögren's syndrome (SS). A real practice-based investigation of a relatively large (n = 110) Dutch cohort of primary SS patients systematically followed up in a large non-academic hospital. After a follow up of mean 8.2 years a significant correlation was found between disease duration and the prevalence of EGOD. We did not observe a relationship between the total number or type of systemic auto-antibodies or hypergammaglobulinemia and the total number of EGOD. However, there was a correlation between the prevalence of polyneuropathy (PNP) and antinuclear antibodies (ANA) as well as anti-Ro/SS-A positivity and there was an inverse relationship between the presence of anti-Ro/SS-A antibodies and primary biliary cirrhosis (PBC). All PBC cases were anti-Ro/SS-A and anti-La/SS-B negative but ANA positive. There was a trend for a higher occurrence of pleuro-pulmonary disease in the ANA negative cases. Although we did not find a relationship between the total number or type of systemic auto-antibodies and the total number of EGOD, there were correlations between specific systemic auto-antibodies and specific types of EGOD. The presence of ANA and anti-Ro/SS-A was associated with the occurrence of PNP, as well as was the absence of anti-Ro/SS-A with PBC. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.
Johnson, J A; Fusaro, R M
1992-01-01
Since window glass absorbs sunlight below 320 nm, it provides a means of assessing sensitivity to longer wavelengths, i.e. UVA and visible radiation. Positive responses to the query of whether symptoms develop in the auto with the windows up must now be interpreted with regard to the possible presence of tinted plastic film on side and rear windows. These films block nearly all UVA radiation, as does the plastic interleaf of windshields. Thus, occupants of an auto equipped with plastic film receive photoprotection from UVB radiation and well into the UVA region. We define three classes of topical sunscreens: (1) conventional UVB screens, (2) broad-spectrum preparations containing a UVB screen and a UVA absorber and (3) browning agents such as dihydroxyacetone (DHA) that produce a skin coloration that absorbs in the low end of the visible region, with overlap into long-wavelength UVA. By considering responses of photosensitive persons in autos with tinted or untinted windows, coupled with efficacy of appropriate sunscreens, we produced an algorithm defining three photosensitivity subsets. Persons sensitive to long-wavelength UVA and/or visible radiation will benefit from tinted auto windows. In particular, patients with lupus erythematosus (LE) have actively promoted legislation allowing tinted windows. Support for their position is documented by recent reports of induction of lesions in LE patients by exposure to UVA and visible radiation. The brown color produced by DHA is a useful adjunct to the screening action of broad-spectrum sunscreens. Development of a durable color overnight allows application of the DHA preparation in the evening, thus eliminating possible interference with sunscreen use during the day.
NASA Astrophysics Data System (ADS)
Li, Changwen; Wei, Jiping; Zhou, Qun; Sun, Suqin
2008-07-01
FT-IR and two-dimensional correlation spectroscopy (2D-IR) technology were applied to discriminate Chinese Sauce liquor from different fermentation positions (top, middle and bottom of fermentation cellar) for the first time. The liquors at top, middle and bottom of fermentation cellar, possessed the characteristic peaks at 1731 cm -1, 1733 cm -1 and 1602 cm -1, respectively. In the 2D correlation infrared spectra, the differences were amplified. A strong auto-peak at 1725 cm -1 showed in the 2D spectra of the Top Liquor, which indicated that the liquor might contain some ester compounds. Different from Top Liquor, three auto-peaks at 1695, 1590 and 1480 cm -1 were identified in 2D spectra of Middle Liquor, which were the characteristic absorption of acid, lactate. In 2D spectra of Bottom Liquor, two auto-peaks at 1570 and 1485 cm -1 indicated that lactate was the major component. As a result, FT-IR and 2D-IR correlation spectra technology provided a rapid and effective method for the quality analysis of the Sauce liquor.
Use of Semi-Autonomous Tools for ISS Commanding and Monitoring
NASA Technical Reports Server (NTRS)
Brzezinski, Amy S.
2014-01-01
As the International Space Station (ISS) has moved into a utilization phase, operations have shifted to become more ground-based with fewer mission control personnel monitoring and commanding multiple ISS systems. This shift to fewer people monitoring more systems has prompted use of semi-autonomous console tools in the ISS Mission Control Center (MCC) to help flight controllers command and monitor the ISS. These console tools perform routine operational procedures while keeping the human operator "in the loop" to monitor and intervene when off-nominal events arise. Two such tools, the Pre-positioned Load (PPL) Loader and Automatic Operators Recorder Manager (AutoORM), are used by the ISS Communications RF Onboard Networks Utilization Specialist (CRONUS) flight control position. CRONUS is responsible for simultaneously commanding and monitoring the ISS Command & Data Handling (C&DH) and Communications and Tracking (C&T) systems. PPL Loader is used to uplink small pieces of frequently changed software data tables, called PPLs, to ISS computers to support different ISS operations. In order to uplink a PPL, a data load command must be built that contains multiple user-input fields. Next, a multiple step commanding and verification procedure must be performed to enable an onboard computer for software uplink, uplink the PPL, verify the PPL has incorporated correctly, and disable the computer for software uplink. PPL Loader provides different levels of automation in both building and uplinking these commands. In its manual mode, PPL Loader automatically builds the PPL data load commands but allows the flight controller to verify and save the commands for future uplink. In its auto mode, PPL Loader automatically builds the PPL data load commands for flight controller verification, but automatically performs the PPL uplink procedure by sending commands and performing verification checks while notifying CRONUS of procedure step completion. If an off-nominal condition occurs during procedure execution, PPL Loader notifies CRONUS through popup messages, allowing CRONUS to examine the situation and choose an option of how PPL loader should proceed with the procedure. The use of PPL Loader to perform frequent, routine PPL uplinks offloads CRONUS to better monitor two ISS systems. It also reduces procedure performance time and decreases risk of command errors. AutoORM identifies ISS communication outage periods and builds commands to lock, playback, and unlock ISS Operations Recorder files. Operation Recorder files are circular buffer files of continually recorded ISS telemetry data. Sections of these files can be locked from further writing, be played back to capture telemetry data that occurred during an ISS loss of signal (LOS) period, and then be unlocked for future recording use. Downlinked Operation Recorder files are used by mission support teams for data analysis, especially if failures occur during LOS. The commands to lock, playback, and unlock Operations Recorder files are encompassed in three different operational procedures and contain multiple user-input fields. AutoORM provides different levels of automation for building and uplinking the commands to lock, playback, and unlock Operations Recorder files. In its automatic mode, AutoORM automatically detects ISS LOS periods, then generates and uplinks the commands to lock, playback, and unlock Operations Recorder files when MCC regains signal with ISS. AutoORM also features semi-autonomous and manual modes which integrate CRONUS more into the command verification and uplink process. AutoORMs ability to automatically detect ISS LOS periods and build the necessary commands to preserve, playback, and release recorded telemetry data greatly offloads CRONUS to perform more high-level cognitive tasks, such as mission planning and anomaly troubleshooting. Additionally, since Operations Recorder commands contain numerical time input fields which are tedious for a human to manually build, AutoORM's ability to automatically build commands reduces operational command errors. PPL Loader and AutoORM demonstrate principles of semi-autonomous operational tools that will benefit future space mission operations. Both tools employ different levels of automation to perform simple and routine procedures, thereby offloading human operators to perform higher-level cognitive tasks. Because both tools provide procedure execution status and highlight off-nominal indications, the flight controller is able to intervene during procedure execution if needed. Semi-autonomous tools and systems that can perform routine procedures, yet keep human operators informed of execution, will be essential in future long-duration missions where the onboard crew will be solely responsible for spacecraft monitoring and control.
Design of a new controller to treat the obstructive sleep apnea
NASA Astrophysics Data System (ADS)
Netzel, Thomas
2002-06-01
The obstructive sleep apnoea (OSA) is a sleep related breathing disorder caused by a relaxation of the upper airway structure during the sleep that leads to a complete closure of the upper airway. The most successful therapy is the nasal continuous positive airway pressure (nCPAP) treatment that keeps the airway opened. More recent devices use an automatic adaptation of the applied pressure. Either the forced oscillation technique (FOT) or the evaluation of the inspiration flow contour are used to evaluate the severity of obstructions. Both methods have disadvantages that may lead to wrong applied pressures. Based on the precise measurement of airflow and mask pressure during nCPAP with a Weinmann SOMNOsmart and additional polysomnography a new parameter set is presented that uses the advantage of both methods to detect the obstructive sleep apnoea. To evaluate the applicability of this parameter set to control Auto-nCPAP-devices a fuzzy-controller is designed under MATLAB/Simulink using an A/D-D/A-converter to control the blower of the SOMNOsmart during Auto-nCPAP-therapy. Obstructive events are detected and treated with a rise of nCPAP-pressure depending on the inspiratory flow requirement. The pressure is lowered after the end of flow limited phases. Although temporary low pressures no oxygen desaturation is recognized by the pulse oxymeter.
Malkan, Ashish; Cappelen-Smith, Cecilia; Beran, Roy; Griffith, Neil; Toong, Catherine; Wang, Min-Xia; Cordato, Dennis
2015-02-01
We report a 37-year-old woman with a 2 month history of proximal muscle weakness and extremely high creatine kinase (21,808 U/L) due to necrotizing auto-immune myositis (NAM) in association with anti-synthetase syndrome. Myositis-specific auto-immune antibody panel was positive for anti-Signal recognition particle and anti-PL-12. CT scan of the chest confirmed interstitial lung disease. Prednisolone, intravenous immunoglobulin and cyclophosphamide therapy was given with gradual improvement. This patient is notable for the unusual combination of NAM and anti-synthetase syndrome with the rare finding of two myositis-specific autoantibodies, which directed testing for associated extramuscular features and management with more aggressive immunotherapy. Copyright © 2014 Elsevier Ltd. All rights reserved.
Irving, W L; James, D K; Stephenson, T; Laing, P; Jameson, C; Oxford, J S; Chakraverty, P; Brown, D W; Boon, A C; Zambon, M C
2000-10-01
To determine whether maternal influenza virus infection in the second and third trimesters of pregnancy results in transplacental transmission of infection, maternal auto-antibody production or an increase in complications of pregnancy. Case-control cohort study. Study and control cohorts were derived from 3,975 women who were consecutively delivered at two Nottingham teaching hospitals between May 1993 and July 1994. A complete set of three sera was available for 1,659 women. Paired maternal ante- and postnatal sera were screened for a rise in anti-influenza virus antibody titre by single radial haemolysis and haemagglutination inhibition. Routine obstetric data collected during and after pregnancy were retrieved from the Nottingham obstetric database. Cord samples were tested for the presence of IgM anti-influenza antibodies, and postnatal infant sera were tested for the persistence of influenza-virus specific IgG. Paired antenatal and postnatal sera were tested against a standard range of auto-antigens by immunofluorescence. Classification of women as having definite serological evidence of an influenza virus infection in pregnancy (cases) or as controls. Intercurrent influenza virus infections were identified in 182/1,659 (11.0%) pregnancies. None of 138 cord sera from maternal influenza cases was positive for influenza A virus specific IgM. IgG anti-influenza antibodies did not persist in any of 12 infant sera taken at age 6-12 months. Six of 172 postnatal maternal sera from cases of influenza were positive for auto-antibodies. In all cases the corresponding antenatal serum was also positive for the same auto-antibody. There were no significant differences in pregnancy outcome measures between cases and controls. Overall, there were significantly more complications of pregnancy in the cases versus the controls, but no single type of complication achieved statistical significance. Influenza infection in the second and third trimesters of pregnancy is a relatively common event. We found no evidence for transplacental transmission of influenza virus or auto-antibody production in pregnancies complicated by influenza infections. There was an increase in the complications of pregnancy in our influenza cohort.
Automated working distance adjustment for a handheld OCT-Laryngoscope
NASA Astrophysics Data System (ADS)
Donner, Sabine; Bleeker, Sebastian; Ripken, Tammo; Krueger, Alexander
2014-03-01
Optical coherence tomography (OCT) is an imaging technique which enables diagnosis of vocal cord tissue structure by non-contact optical biopsies rather than invasive tissue biopsies. For diagnosis on awake patients OCT was adapted to a rigid indirect laryngoscope. The working distance must match the probe-sample distance, which varies from patient to patient. Therefore the endoscopic OCT sample arm has a variable working distance of 40 mm to 80 mm. The current axial position is identified by automated working distance adjustments based on image processing. The OCT reference plane and the focal plane of the sample arm are moved according to position errors. Repeated position adjustment during the whole diagnostic procedure keeps the tissue sample at the optimal axial position. The auto focus identifies and adjusts the working distance within the range of 50 mm within a maximum time of 2.7 s. Continuous image stabilisation reduces axial sample movement within the sampling depth for handheld OCT scanning. Rapid autofocus reduces the duration of the diagnostic procedure and axial position stabilisation eases the use of the OCT laryngoscope. Therefore this work is an important step towards the integration of OCT into indirect laryngoscopes.
Seyed Moosavi, Seyed Mohsen; Moaveni, Bijan; Moshiri, Behzad; Arvan, Mohammad Reza
2018-02-27
The present study designed skewed redundant accelerometers for a Measurement While Drilling (MWD) tool and executed auto-calibration, fault diagnosis and isolation of accelerometers in this tool. The optimal structure includes four accelerometers was selected and designed precisely in accordance with the physical shape of the existing MWD tool. A new four-accelerometer structure was designed, implemented and installed on the current system, replacing the conventional orthogonal structure. Auto-calibration operation of skewed redundant accelerometers and all combinations of three accelerometers have been done. Consequently, biases, scale factors, and misalignment factors of accelerometers have been successfully estimated. By defecting the sensors in the new optimal skewed redundant structure, the fault was detected using the proposed FDI method and the faulty sensor was diagnosed and isolated. The results indicate that the system can continue to operate with at least three correct sensors.
Seyed Moosavi, Seyed Mohsen; Moshiri, Behzad; Arvan, Mohammad Reza
2018-01-01
The present study designed skewed redundant accelerometers for a Measurement While Drilling (MWD) tool and executed auto-calibration, fault diagnosis and isolation of accelerometers in this tool. The optimal structure includes four accelerometers was selected and designed precisely in accordance with the physical shape of the existing MWD tool. A new four-accelerometer structure was designed, implemented and installed on the current system, replacing the conventional orthogonal structure. Auto-calibration operation of skewed redundant accelerometers and all combinations of three accelerometers have been done. Consequently, biases, scale factors, and misalignment factors of accelerometers have been successfully estimated. By defecting the sensors in the new optimal skewed redundant structure, the fault was detected using the proposed FDI method and the faulty sensor was diagnosed and isolated. The results indicate that the system can continue to operate with at least three correct sensors. PMID:29495434
Ravindranath, Pradeep Anand; Sanner, Michel F.
2016-01-01
Motivation: The identification of ligand-binding sites from a protein structure facilitates computational drug design and optimization, and protein function assignment. We introduce AutoSite: an efficient software tool for identifying ligand-binding sites and predicting pseudo ligand corresponding to each binding site identified. Binding sites are reported as clusters of 3D points called fills in which every point is labelled as hydrophobic or as hydrogen bond donor or acceptor. From these fills AutoSite derives feature points: a set of putative positions of hydrophobic-, and hydrogen-bond forming ligand atoms. Results: We show that AutoSite identifies ligand-binding sites with higher accuracy than other leading methods, and produces fills that better matches the ligand shape and properties, than the fills obtained with a software program with similar capabilities, AutoLigand. In addition, we demonstrate that for the Astex Diverse Set, the feature points identify 79% of hydrophobic ligand atoms, and 81% and 62% of the hydrogen acceptor and donor hydrogen ligand atoms interacting with the receptor, and predict 81.2% of water molecules mediating interactions between ligand and receptor. Finally, we illustrate potential uses of the predicted feature points in the context of lead optimization in drug discovery projects. Availability and Implementation: http://adfr.scripps.edu/AutoDockFR/autosite.html Contact: sanner@scripps.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:27354702
1980-11-01
to auto ignite in color cinematography of the process. It appears the above interaction reduces classical wall quench(14 ) as the reaction continues...vivid blue hue while the core reaction is white. Continuation of the reaction is seen in the first four frames of Fig. V-3; this figure covers the time
Klyuchnikov, Evgeny; Bacher, Ulrike; Kröger, Nicolaus M; Hari, Parameswaran N; Ahn, Kwang Woo; Carreras, Jeanette; Bachanova, Veronika; Bashey, Asad; Cohen, Jonathon B; D'Souza, Anita; Freytes, César O; Gale, Robert Peter; Ganguly, Siddhartha; Hertzberg, Mark S; Holmberg, Leona A; Kharfan-Dabaja, Mohamed A; Klein, Andreas; Ku, Grace H; Laport, Ginna G; Lazarus, Hillard M; Miller, Alan M; Mussetti, Alberto; Olsson, Richard F; Slavin, Shimon; Usmani, Saad Z; Vij, Ravi; Wood, William A; Maloney, David G; Sureda, Anna M; Smith, Sonali M; Hamadani, Mehdi
2015-12-01
This study was conducted to compare long-term outcomes in patients with refractory/relapsed grades 1 and 2 follicular lymphoma (FL) after allogeneic (allo) versus autologous (auto) hematopoietic cell transplantation (HCT) in the rituximab era. Adult patients with relapsed/refractory grades 1 and 2 FL undergoing first reduced-intensity allo-HCT or first autograft during 2000 to 2012 were evaluated. A total of 518 rituximab-treated patients were included. Allo-HCT patients were younger and more heavily pretreated, and more patients had advanced stage and chemoresistant disease. The 5-year adjusted probabilities, comparing auto-HCT versus allo-HCT groups for nonrelapse mortality (NRM) were 5% versus 26% (P < .0001); relapse/progression: 54% versus 20% (P < .0001); progression-free survival (PFS): 41% versus 58% (P < .001), and overall survival (OS): 74% versus 66% (P = .05). Auto-HCT was associated with a higher risk of relapse/progression beyond 5 months after HCT (relative risk [RR], 4.4; P < .0001) and worse PFS (RR, 2.9; P < .0001) beyond 11 months after HCT. In the first 24 months after HCT, auto-HCT was associated with improved OS (RR, .41; P < .0001), but beyond 24 months, it was associated with inferior OS (RR, 2.2; P = .006). A landmark analysis of patients alive and progression-free at 2 years after HCT confirmed these observations, showing no difference in further NRM between both groups, but there was significantly higher risk of relapse/progression (RR, 7.3; P < .0001) and inferior PFS (RR, 3.2; P < .0001) and OS (RR, 2.1; P = .04) after auto-HCT. The 10-year cumulative incidences of second hematological malignancies after allo-HCT and auto-HCT were 0% and 7%, respectively. Auto-HCT and reduced-intensity-conditioned allo-HCT as first transplantation approach can provide durable disease control in grades 1 and 2 FL patients. Continued disease relapse risk after auto-HCT translates into improved PFS and OS after allo-HCT in long-term survivors. Copyright © 2015 American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
Pockley, Alan Graham; Lindsay, James O.; Foulds, Gemma A.; Rutella, Sergio; Gribben, John G.; Alexander, Tobias; Snowden, John A.
2018-01-01
Patients with treatment refractory Crohn’s disease (CD) suffer debilitating symptoms, poor quality of life, and reduced work productivity. Surgery to resect inflamed and fibrotic intestine may mandate creation of a stoma and is often declined by patients. Such patients continue to be exposed to medical therapy that is ineffective, often expensive and still associated with a burden of adverse effects. Over the last two decades, autologous hematopoietic stem cell transplantation (auto-HSCT) has emerged as a promising treatment option for patients with severe autoimmune diseases (ADs). Mechanistic studies have provided proof of concept that auto-HSCT can restore immunological tolerance in chronic autoimmunity via the eradication of pathological immune responses and a profound reconfiguration of the immune system. Herein, we review current experience of auto-HSCT for the treatment of CD as well as approaches that have been used to monitor immune reconstitution following auto-HSCT in patients with ADs, including CD. We also detail immune reconstitution studies that have been integrated into the randomized controlled Autologous Stem cell Transplantation In refractory CD—Low Intensity Therapy Evaluation trial, which is designed to test the hypothesis that auto-HSCT using reduced intensity mobilization and conditioning regimens will be a safe and effective means of inducing sustained control in refractory CD compared to standard of care. Immunological profiling will generate insight into the pathogenesis of the disease, restoration of responsiveness to anti-TNF therapy in patients with recurrence of endoscopic disease and immunological events that precede the onset of disease in patients that relapse after auto-HSCT. PMID:29670622
49 CFR Appendix E to Part 236 - Human-Machine Interface (HMI) Design
Code of Federal Regulations, 2013 CFR
2013-10-01
... operator to change position; (4) Arrange controls according to their expected order of use; (5) Group similar controls together; (6) Design for high stimulus-response compatibility (geometric and conceptual); (7) Design safety-critical controls to require more than one positive action to activate (e.g., auto...
49 CFR Appendix E to Part 236 - Human-Machine Interface (HMI) Design
Code of Federal Regulations, 2010 CFR
2010-10-01
... operator to change position; (4) Arrange controls according to their expected order of use; (5) Group similar controls together; (6) Design for high stimulus-response compatibility (geometric and conceptual); (7) Design safety-critical controls to require more than one positive action to activate (e.g., auto...
49 CFR Appendix E to Part 236 - Human-Machine Interface (HMI) Design
Code of Federal Regulations, 2014 CFR
2014-10-01
... operator to change position; (4) Arrange controls according to their expected order of use; (5) Group similar controls together; (6) Design for high stimulus-response compatibility (geometric and conceptual); (7) Design safety-critical controls to require more than one positive action to activate (e.g., auto...
49 CFR Appendix E to Part 236 - Human-Machine Interface (HMI) Design
Code of Federal Regulations, 2011 CFR
2011-10-01
... operator to change position; (4) Arrange controls according to their expected order of use; (5) Group similar controls together; (6) Design for high stimulus-response compatibility (geometric and conceptual); (7) Design safety-critical controls to require more than one positive action to activate (e.g., auto...
49 CFR Appendix E to Part 236 - Human-Machine Interface (HMI) Design
Code of Federal Regulations, 2012 CFR
2012-10-01
... operator to change position; (4) Arrange controls according to their expected order of use; (5) Group similar controls together; (6) Design for high stimulus-response compatibility (geometric and conceptual); (7) Design safety-critical controls to require more than one positive action to activate (e.g., auto...
NASA Astrophysics Data System (ADS)
Qu, Lei; Chen, Jian-bo; Zhou, Qun; Zhang, Gui-jun; Sun, Su-qin; Guo, Yi-zhen
2016-11-01
As a kind of expensive perfume and valuable herb, the commercial Aquilariae Lignum Resinatum (ALR) is often adulterated for economic motivations. In this research, Fourier transform infrared (FT-IR) spectroscopy and two-dimensional (2D) correlation analysis are employed to establish a simple and quick identification method for the authentic and adulterated ALR. In the conventional infrared spectra, the standard ALR has a strong peak at 1658 cm-1 referring to the conjugated carbonyl of resin, while this peak is absent in the adulterated samples. The position, intensity, and shape of the auto-peaks and cross-peaks of the authentic and adulterated ALR are much different in the synchronous 2D correlation spectra with thermal perturbation. In the range of 1700-1500 cm-1, the standard ALR has four obvious auto-peaks, while the strongest one is at 1659 cm-1. The adulterated sample w-1 has three obvious auto-peaks and the strongest one is at 1647 cm-1. The adulterated sample w-2 has three obvious auto-peaks and the strongest one is at 1519 cm-1. The adulterated sample w-3 has four obvious auto-peaks and the strongest one is at 1690 cm-1. The above auto-peaks confirm that the standard ALR contains a certain content of resin compounds, while the three counterfeits contain little or different resins. The results show the potential of FT-IR spectroscopy and 2D correlation analysis in the simple and quick identification of authentic and adulterated ALR.
Giebel, Sebastian; Labopin, Myriam; Potter, Michael; Poiré, Xavier; Sengeloev, Henrik; Socié, Gerard; Huynh, Anne; Afanasyev, Boris V; Schanz, Urs; Ringden, Olle; Kalhs, Peter; Beelen, Dietrich W; Campos, Antonio M; Masszi, Tamás; Canaani, Jonathan; Mohty, Mohamad; Nagler, Arnon
2018-06-01
Allogeneic haematopoietic stem cell transplantation (alloHSCT) is considered a standard treatment for patients with Philadelphia chromosome-positive acute lymphoblastic leukaemia (Ph+ ALL) achieving complete remission after induction containing tyrosine kinase inhibitors (TKIs). We retrospectively compared results of myeloablative alloHSCT from either matched sibling donor (MSD) or unrelated donor (URD) with autologous (auto) HSCT for adults with Ph+ ALL in molecular remission, treated between 2007 and 2014. In univariate analysis, the incidence of relapse at 2 years was 47% after autoHSCT, 28% after MSD-HSCT and 19% after URD-HSCT (P = 0.0002). Respective rates of non-relapse mortality were 2%, 18%, and 22% (P = 0.001). The probabilities of leukaemia-free survival were 52%, 55% and 60% (P = 0.69), while overall survival rates were 70%, 70% and 69% (P = 0.58), respectively. In multivariate analysis, there was a trend towards increased risk of overall mortality after MSD-HSCT (hazard ratio [HR], 1.5, P = 0.12) and URD-HSCT (HR, 1.6, P = 0.08) when referred to autoHSCT. The use of total body irradiation (TBI)-based regimens was associated with reduced risk of relapse (HR, 0.65, P = 0.02) and overall mortality (HR, 0.67, P = 0.01). In the era of TKIs, outcomes of myeloablative autoHSCT and alloHSCT for patients with Ph+ ALL in first molecular remission are comparable. Therefore, autoHSCT appears to be an attractive treatment option potentially allowing for circumvention of alloHSCT sequelae. Irrespective of the type of donor, TBI-based regimens should be considered the preferable type of conditioning for Ph+ ALL. Copyright © 2018 Elsevier Ltd. All rights reserved.
Accelerated bone mass senescence after hematopoietic stem cell transplantation.
Serio, B; Pezzullo, L; Fontana, R; Annunziata, S; Rosamilio, R; Sessa, M; Giudice, V; Ferrara, I; Rocco, M; De Rosa, G; Ricci, P; Tauchmanovà, L; Montuori, N; Selleri, C
2013-01-01
Osteoporosis and avascular necrosis (AVN) are long-lasting and debilitating complications of hematopoietic stem cell transplantation (HSCT). We describe the magnitude of bone loss, AVN and impairment in osteogenic cell compartment following autologous (auto) and allogeneic (allo) HSCT, through the retrospective bone damage revaluation of 100 (50 auto- and 50 allo-HSCT) long-term survivors up to 15 years after transplant. Current treatment options for the management of these complications are also outlined. We found that auto- and allo-HSCT recipients show accelerated bone mineral loss and micro-architectural deterioration during the first years after transplant. Bone mass density (BMD) at the lumbar spine, but not at the femur neck, may improve in some patients after HSCT, suggesting more prolonged bone damage in cortical bone. Phalangeal BMD values remained low for even more years, suggesting persistent bone micro-architectural alterations after transplant. The incidence of AVN was higher in allo-HSCT recipients compared to auto-HSCT recipients. Steroid treatment length, but not its cumulative dose was associated with a higher incidence of bone loss. Allo-HSCT recipients affected by chronic graft versus host disease seem to be at greater risk of continuous bone loss and AVN development. Reduced BMD and higher incidence of AVN was partly related to a reduced regenerating capacity of the normal marrow osteogenic cell compartment. Our results suggest that all patients after auto-HSCT and allo-HSCT should be evaluated for their bone status and treated with anti-resorptive therapy as soon as abnormalities are detected.
Huguet, S; Sghiri, R; Ballot, E; Johanet, C
2004-01-01
The Cyto-Dot 4 HM043 kit commercialised by BMD, has replaced the Cyto-Dot HM010 kit that allowed three auto-antibodies detection (anti-Jo-1, anti-M2 and anti-ribosomal protein). Detection of anti-LKM1 auto-antibody was added. These four auto-antibodies have in common only the intracytoplasmic localisation of their respective antigen. The aim of our study was to evaluate this new kit using 104 sera and to compare our results with reference techniques (indirect immunofluorescence IF for anti-M2, anti-ribosomal protein and anti-LKM1, double immunodiffusion ID for anti-Jo-1 and anti-LKM1, western blotting WB for anti-M2) and with Cyto-Dot HM010. The one hundred and four sera were divided into five groups: Group I (n = 12) with anti-Jo-1 detected by ID; Group II (n = 28) with 26 anti-M2 positive by IF and WB, 2 anti-M2 positive only by WB; Group III (n = 10) with anti-ribosomal protein detected by IF 5 of which precipitated by ID; Group IV (n = 32) with anti-LKM1 by IF and ID divided into 18 AIH2 and 14 HCV; Group V (n = 22) consisting of 14 healthy individuals and 8 patients with hypergammaglobulinemia. Results of this study are similar to those of Cyto-Dot HM010 for the three auto-antibodies already in use. Cyto-Dot 4 is a very good anti-LKM1 confirmation method as it is ID. Copyright John Libbey Eurotext 2003.
Reflector automatic acquisition and pointing based on auto-collimation theodolite.
Luo, Jun; Wang, Zhiqian; Wen, Zhuoman; Li, Mingzhu; Liu, Shaojin; Shen, Chengwu
2018-01-01
An auto-collimation theodolite (ACT) for reflector automatic acquisition and pointing is designed based on the principle of autocollimators and theodolites. First, the principle of auto-collimation and theodolites is reviewed, and then the coaxial ACT structure is developed. Subsequently, the acquisition and pointing strategies for reflector measurements are presented, which first quickly acquires the target over a wide range and then points the laser spot to the charge coupled device zero position. Finally, experiments are conducted to verify the acquisition and pointing performance, including the calibration of the ACT, the comparison of the acquisition mode and pointing mode, and the accuracy measurement in horizontal and vertical directions. In both directions, a measurement accuracy of ±3″ is achieved. The presented ACT is suitable for automatic pointing and monitoring the reflector over a small scanning area and can be used in a wide range of applications such as bridge structure monitoring and cooperative target aiming.
Reflector automatic acquisition and pointing based on auto-collimation theodolite
NASA Astrophysics Data System (ADS)
Luo, Jun; Wang, Zhiqian; Wen, Zhuoman; Li, Mingzhu; Liu, Shaojin; Shen, Chengwu
2018-01-01
An auto-collimation theodolite (ACT) for reflector automatic acquisition and pointing is designed based on the principle of autocollimators and theodolites. First, the principle of auto-collimation and theodolites is reviewed, and then the coaxial ACT structure is developed. Subsequently, the acquisition and pointing strategies for reflector measurements are presented, which first quickly acquires the target over a wide range and then points the laser spot to the charge coupled device zero position. Finally, experiments are conducted to verify the acquisition and pointing performance, including the calibration of the ACT, the comparison of the acquisition mode and pointing mode, and the accuracy measurement in horizontal and vertical directions. In both directions, a measurement accuracy of ±3″ is achieved. The presented ACT is suitable for automatic pointing and monitoring the reflector over a small scanning area and can be used in a wide range of applications such as bridge structure monitoring and cooperative target aiming.
O'Leary, D D; Lin, D C; Hughson, R L
1999-09-01
The heart rate component of the arterial baroreflex gain (BRG) was determined with auto-regressive moving-average (ARMA) analysis during each of spontaneous (SB) and random breathing (RB) protocols. Ten healthy subjects completed each breathing pattern on two different days in each of two different body positions, supine (SUP) and head-up tilt (HUT). The R-R interval, systolic arterial pressure (SAP) and instantaneous lung volume were recorded continuously. BRG was estimated from the ARMA impulse response relationship of R-R interval to SAP and from the spontaneous sequence method. The results indicated that both the ARMA and spontaneous sequence methods were reproducible (r = 0.76 and r = 0.85, respectively). As expected, BRG was significantly less in the HUT compared to SUP position for both ARMA (mean +/- SEM; 3.5 +/- 0.3 versus 11.2 +/- 1.4 ms mmHg-1; P < 0.01) and spontaneous sequence analysis (10.3 +/- 0.8 versus 31.5 +/- 2.3 ms mmHg-1; P < 0.001). However, no significant difference was found between BRG during RB and SB protocols for either ARMA (7.9 +/- 1.4 versus 6.7 +/- 0.8 ms mmHg-1; P = 0.27) or spontaneous sequence methods (21.8 +/- 2.7 versus 20.0 +/- 2.1 ms mmHg-1; P = 0.24). BRG was correlated during RB and SB protocols (r = 0.80; P < 0.0001). ARMA and spontaneous BRG estimates were correlated (r = 0.79; P < 0.0001), with spontaneous sequence values being consistently larger (P < 0.0001). In conclusion, we have shown that ARMA-derived BRG values are reproducible and that they can be determined during SB conditions, making the ARMA method appropriate for use in a wider range of patients.
ERIC Educational Resources Information Center
Adler, Paul S.
1993-01-01
A General Motors-Toyota auto assembly plant demonstrates how hierarchy and standardization can improve productivity and motivate workers. The production system is strongly committed to the social context of work and focused on standards designed by workers themselves, giving continuous improvement a specific foundation. (SK)
Pulse-excited, auto-zeroing multiple channel data transmission system
NASA Astrophysics Data System (ADS)
Fasching, G. E.
1985-02-01
A multiple channel data transmission system is provided in which signals from a plurality of pulse operated transducers and a corresponding plurality of pulse operated signal processor channels are multiplexed for single channel FM transmission to a receiving station. The transducers and corresponding channel amplifiers are powered by pulsing the dc battery power to these devices to conserve energy and battery size for long-term data transmission from remote or inaccessible locations. Auto zeroing of the signal channel amplifiers to compensate for drift associated with temperature changes, battery decay, component aging, etc., in each channel is accomplished by means of a unique auto zero feature which between signal pulses holds a zero correction voltage on an integrating capacitor coupled to the corresponding channel amplifier output. Pseudo-continuous outputs for each channel are achieved by pulsed sample-and-hold circuits which are updated at the pulsed operation rate. The sample-and-hold outputs are multiplexed into an FM/FM transmitter for transmission to an FM receiver station for demultiplexing and storage in separate channel recorders.
Pulse-excited, auto-zeroing multiple channel data transmission system
Fasching, G.E.
1985-02-22
A multiple channel data transmission system is provided in which signals from a plurality of pulse operated transducers and a corresponding plurality of pulse operated signal processor channels are multiplexed for single channel FM transmission to a receiving station. The transducers and corresponding channel amplifiers are powered by pulsing the dc battery power to these devices to conserve energy and battery size for long-term data transmission from remote or inaccessible locations. Auto zeroing of the signal channel amplifiers to compensate for drift associated with temperature changes, battery decay, component aging, etc., in each channel is accomplished by means of a unique auto zero feature which between signal pulses holds a zero correction voltage on an integrating capacitor coupled to the corresponding channel amplifier output. Pseudo-continuous outputs for each channel are achieved by pulsed sample-and-hold circuits which are updated at the pulsed operation rate. The sample-and-hold outputs are multiplexed into an FM/FM transmitter for transmission to an FM receiver station for demultiplexing and storage in separate channel recorders.
Pulse-excited, auto-zeroing multiple channel data transmission system
Fasching, George E.
1987-01-01
A multiple channel data transmission system is provided in which signals from a plurality of pulse operated transducers and a corresponding plurality of pulse operated signal processor channels are multiplexed for single channel FM transmission to a receiving station. The transducers and corresponding channel amplifiers are powered by pulsing the dc battery power to these devices to conserve energy and battery size for long-term data transmission from remote or inaccessible locations. Auto zeroing of the signal channel amplifiers to compensate for drift associated with temperature changes, battery decay, component aging, etc., in each channel is accomplished by means of a unique auto zero feature which between signal pulses holds a zero correction voltage on an integrating capacitor coupled to the corresponding channel amplifier output. Pseudo-continuous outputs for each channel are achieved by pulsed sample-and-hold circuits which are updated at the pulsed operation rate. The sample-and-hold outputs are multiplexed into an FM/FM transmitter for transmission to an FM receiver station for demultiplexing and storage in separate channel recorders.
Several years of experience with automatic DI-flux systems: theory, validation and results
NASA Astrophysics Data System (ADS)
Poncelet, Antoine; Gonsette, Alexandre; Rasson, Jean
2017-09-01
The previous release of our automatic DI-flux instrument, called AutoDIF mk2.2, has now been running continuously since June 2012 in the absolute house of Dourbes magnetic observatory performing measurement every 30 min. A second one has been working in the tunnel of Conrad observatory (Austria) since December 2013. After this proof of concept, we improved the AutoDIF to version mk2.3, which was presented at the 16th IAGA workshop in Hyderabad. As of publication, we have successfully deployed six AutoDIFs in various environments: two in Dourbes (DOU), one in Manhay (MAB), one in Conrad (CON), one in Daejeon (South Korea) and one is used for tests. The latter was installed for 10 months in Chambon-la-Forêt (CLF) and, since 2016, has been in Kakioka (KAK). In this paper, we will compare the automatic to the human-made measurements and discuss the advantages and disadvantages of automatic measurements.
AutoDockFR: Advances in Protein-Ligand Docking with Explicitly Specified Binding Site Flexibility
Ravindranath, Pradeep Anand; Forli, Stefano; Goodsell, David S.; Olson, Arthur J.; Sanner, Michel F.
2015-01-01
Automated docking of drug-like molecules into receptors is an essential tool in structure-based drug design. While modeling receptor flexibility is important for correctly predicting ligand binding, it still remains challenging. This work focuses on an approach in which receptor flexibility is modeled by explicitly specifying a set of receptor side-chains a-priori. The challenges of this approach include the: 1) exponential growth of the search space, demanding more efficient search methods; and 2) increased number of false positives, calling for scoring functions tailored for flexible receptor docking. We present AutoDockFR–AutoDock for Flexible Receptors (ADFR), a new docking engine based on the AutoDock4 scoring function, which addresses the aforementioned challenges with a new Genetic Algorithm (GA) and customized scoring function. We validate ADFR using the Astex Diverse Set, demonstrating an increase in efficiency and reliability of its GA over the one implemented in AutoDock4. We demonstrate greatly increased success rates when cross-docking ligands into apo receptors that require side-chain conformational changes for ligand binding. These cross-docking experiments are based on two datasets: 1) SEQ17 –a receptor diversity set containing 17 pairs of apo-holo structures; and 2) CDK2 –a ligand diversity set composed of one CDK2 apo structure and 52 known bound inhibitors. We show that, when cross-docking ligands into the apo conformation of the receptors with up to 14 flexible side-chains, ADFR reports more correctly cross-docked ligands than AutoDock Vina on both datasets with solutions found for 70.6% vs. 35.3% systems on SEQ17, and 76.9% vs. 61.5% on CDK2. ADFR also outperforms AutoDock Vina in number of top ranking solutions on both datasets. Furthermore, we show that correctly docked CDK2 complexes re-create on average 79.8% of all pairwise atomic interactions between the ligand and moving receptor atoms in the holo complexes. Finally, we show that down-weighting the receptor internal energy improves the ranking of correctly docked poses and that runtime for AutoDockFR scales linearly when side-chain flexibility is added. PMID:26629955
Damiani, Mario Francesco; Quaranta, Vitaliano Nicola; Tedeschi, Ersilia; Drigo, Riccardo; Ranieri, Teresa; Carratù, Pierluigi; Resta, Onofrio
2013-08-01
Nocturnal application of continuous positive airway pressure (CPAP) is the standard treatment for patients with obstructive sleep apnoea (OSA). Determination of the therapeutic pressure (CPAP titration) is usually performed by a technician in the sleep laboratory during attended polysomnography. One possible alternative to manual titration is automated titration. Indeed, during the last 15 years, devices have been developed that deliver autoadjustable CPAP (A-CPAP). The aim of the present study was to compare the titration effectiveness of two A-CPAP devices using different flow-based algorithms in patients with OSA. This is a randomized study; 79 subjects underwent two consecutive unattended home A-CPAP titration nights with two different devices (Autoset Resmed; Remstar Auto Respironics); during the third and the fourth night, patients underwent portable monitoring in the sleep laboratory during fixed CPAP at the A-CPAP recommended pressure. Bland Altman plots showed good agreement between the recommended median and maximal pressure levels obtained with the two devices. A significant improvement was observed in all the sleep parameters by both A-CPAP machines to a similar degree. It was observed that the two A-CPAP devices using different algorithms are equally effective in initial titration of CPAP. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.
Zuo, Bin; Zhao, Yun-Xiao; Yang, Jian-Feng; He, Yang
2015-08-01
To investigate whether the plasma level of platelet auto- antibodies in ITP patients is related to that of co-stimulatory molecules sB7-H2 and sB7-H3. A total of 61 ITP patients and 25 healthy controls from the First Affiliated Hospital of Soochow University from June 2012 to August 2013 were enrolled in this study. The expression levels of platelet auto-antibodies against 5 glycoproteins (GPIX, GP Ib, GP IIIa, GPIIb and P-selectin) in plasma were detected by flow cytometric immuno-beads array, and the expression of soluable co-stimulatory molecules sB7-H2 and sB7-H3 was measured by ELISA. The plasma levels of 5 auto-antibodies against platelet membrance glycoproteins significantly increased in ITP patiens (P < 0.01). Compared with healthy controls, sB7-H2 levels increased (P < 0.05), while the sB7-H3 level did not significantly change (r = 0.13, P > 0.05). However, the correlation analysis showed that sB7-H3 negatively correlated with platelet P-selectin auto-antibody (r = -0.46, P < 0.05), and sB7-H2 and sB7-H3 significantly reduced in ITP patients with positive P-selectin auto-antibody (P < 0.01). In ITP patients, platelet counts negatively correlated with sB7-H2 (r = -0.3907, P < 0.01), but did not correlate with sB7-H3. Soluble costimulatory molecule sB7-H2 elevates in ITP patients, and the level of sB7-H3 is associated with auto-antibodies against P-selectin, suggesting that costimulatory molecules B7-H2 and B7-H3 may be involved in the pathogenesis of immune regulation abnormality in ITP.
Berlowitz, David J; Ayas, Najib; Barnes, Maree; Brown, Douglas J; Cistulli, Peter A; Geraghty, Tim; Graham, Alison; Lee, Bonsan Bonne; Morris, Meg; O'Donoghue, Fergal; Rochford, Peter D; Ross, Jack; Singhal, Balraj; Spong, Jo; Wadsworth, Brooke; Pierce, Robert J
2013-06-19
Quadriplegia is a severe, catastrophic injury that predominantly affects people early in life, resulting in lifelong physical disability. Obstructive sleep apnoea is a direct consequence of quadriplegia and is associated with neurocognitive deficits, sleepiness and reduced quality of life. The usual treatment for sleep apnoea is nasal continuous positive airway pressure (CPAP); however, this is poorly tolerated in quadriplegia. To encourage patients to use this therapy, we have to demonstrate that the benefits outweigh the inconvenience. We therefore propose a prospective, multinational randomized controlled trial of three months of CPAP for obstructive sleep apnoea after acute quadriplegia. Specialist spinal cord injury centres across Australia, New Zealand, the UK and Canada will recruit medically stable individuals who have sustained a (new) traumatic quadriplegia (complete or incomplete second cervical to first thoracic level lesions). Participants will be screened for obstructive sleep apnoea using full, portable sleep studies. Those with an apnoea hypopnoea index greater than 10 per hour will proceed to an initial three-night trial of CPAP. Those who can tolerate CPAP for at least 4 hours on at least one night of the initial trial will be randomized to either usual care or a 3-month period of auto-titrating CPAP. The primary hypothesis is that nocturnal CPAP will improve neuropsychological functioning more than usual care alone. The secondary hypothesis is that the magnitude of improvement of neuropsychological function will be predicted by the severity of baseline sleepiness measures, sleep fragmentation and sleep apnoea. Neuropsychological tests and full polysomnography will be performed at baseline and 3 months with interim measures of sleepiness and symptoms of autonomic dysfunction measured weekly. Spirometry will be performed monthly. Neuropsychological tests will be administered by blinded assessors. Recruitment commenced in July 2009. The results of this trial will demonstrate the effect of nocturnal CPAP treatment of obstructive sleep apnoea in acute quadriplegia. If CPAP can improve neurocognitive function after injury, it is likely that rehabilitation and subsequent community participation will be substantially improved for this group of predominantly young and severely physically disabled people. Australian New Zealand Clinical Trial Registry ACTRN12605000799651.
Qing, Feng Ting; Peng, Yu
2016-05-01
Based on the remote sensing data in 1997, 2001, 2005, 2009 and 2013, this article classified the landscape types of Shunyi, and the ecological risk index was built based on landscape disturbance index and landscape fragility. The spatial auto-correlation and geostatistical analysis by GS + and ArcGIS was used to study temporal and spatial changes of ecological risk. The results showed that eco-risk degree in the study region had positive spatial correlation which decreased with the increasing grain size. Within a certain grain range (<12 km), the spatial auto-correlation had an obvious dependence on scale. The random variation of spatial heterogeneity was less than spatial auto-correlation variation from 1997 to 2013, which meant the auto-correlation had a dominant role in spatial heterogeneity. The ecological risk of Shunyi was mainly at moderate level during the study period. The area of the district with higher and lower ecological risk increased, while that of mode-rate ecological risk decreased. The area with low ecological risk was mainly located in the airport region and forest of southeast Shunyi, while that with high ecological risk was mainly concentrated in the water landscape, such as the banks of Chaobai River.
The Value of Strategic Partnerships
Gould, Josh; Narayan, Amit; McNutt, Ty
2018-05-30
Strong strategic partnerships can be the difference between those technologies that only achieve success in the lab and those that actually break into the marketplace. Two ARPA-E awardeesâAutoGrid and APEIâhave forged strategic partnerships that have positioned their technologies to achieve major success in the market. This video features remarks from ARPA-E Technology-to-Market Advisor Josh Gould and interviews with technologists at AutoGrid and APEI, who each tell the story of how their company leveraged relationships with strategic partners to broaden their customer base and bring their technology to life.
A passive autofocus system by using standard deviation of the image on a liquid lens
NASA Astrophysics Data System (ADS)
Rasti, Pejman; Kesküla, Arko; Haus, Henry; Schlaak, Helmut F.; Anbarjafari, Gholamreza; Aabloo, Alvo; Kiefer, Rudolf
2015-04-01
Today most of applications have a small camera such as cell phones, tablets and medical devices. A micro lens is required in order to reduce the size of the devices. In this paper an auto focus system is used in order to find the best position of a liquid lens without any active components such as ultrasonic or infrared. In fact a passive auto focus system by using standard deviation of the images on a liquid lens which consist of a Dielectric Elastomer Actuator (DEA) membrane between oil and water is proposed.
Continuous Monitoring of Essential Tremor Using a Portable System Based on Smartwatch.
Zheng, Xiaochen; Vieira Campos, Alba; Ordieres-Meré, Joaquín; Balseiro, Jose; Labrador Marcos, Sergio; Aladro, Yolanda
2017-01-01
Essential tremor (ET) shows amplitude fluctuations throughout the day, presenting challenges in both clinical and treatment monitoring. Tremor severity is currently evaluated by validated rating scales, which only provide a timely and subjective assessment during a clinical visit. Motor sensors have shown favorable performances in quantifying tremor objectively. A new highly portable system was used to monitor tremor continuously during daily lives. It consists of a smartwatch with a triaxial accelerometer, a smartphone, and a remote server. An experiment was conducted involving eight ET patients. The average effective data collection time per patient was 26 (±6.05) hours. Fahn-Tolosa-Marin Tremor Rating Scale (FTMTRS) was adopted as the gold standard to classify tremor and to validate the performance of the system. Quantitative analysis of tremor severity on different time scales is validated. Significant correlations were observed between neurologist's FTMTRS and patient's FTMTRS auto-assessment scores ( r = 0.84; p = 0.009), between the device quantitative measures and the scores from the standardized assessments of neurologists ( r = 0.80; p = 0.005) and patient's auto-evaluation ( r = 0.97; p = 0.032), and between patient's FTMTRS auto-assessment scores day-to-day ( r = 0.87; p < 0.001). A graphical representation of four patients with different degrees of tremor was presented, and a representative system is proposed to summarize the tremor scoring at different time scales. This study demonstrates the feasibility of prolonged and continuous monitoring of tremor severity during daily activities by a highly portable non-restrictive system, a useful tool to analyze efficacy and effectiveness of treatment.
Can we still dream when the mind is blank? Sleep and dream mentations in auto-activation deficit.
Leu-Semenescu, Smaranda; Uguccioni, Ginevra; Golmard, Jean-Louis; Czernecki, Virginie; Yelnik, Jerome; Dubois, Bruno; Forgeot d'Arc, Baudouin; Grabli, David; Levy, Richard; Arnulf, Isabelle
2013-10-01
Bilateral damage to the basal ganglia causes auto-activation deficit, a neuropsychological syndrome characterized by striking apathy, with a loss of self-driven behaviour that is partially reversible with external stimulation. Some patients with auto-activation deficit also experience a mental emptiness, which is defined as an absence of any self-reported thoughts. We asked whether this deficit in spontaneous activation of mental processing may be reversed during REM sleep, when dreaming activity is potentially elicited by bottom-up brainstem stimulation on the cortex. Sleep and video monitoring over two nights and cognitive tests were performed on 13 patients with auto-activation deficit secondary to bilateral striato-pallidal lesions and 13 healthy subjects. Dream mentations were collected from home diaries and after forced awakenings in non-REM and REM sleep. The home diaries were blindly analysed for length, complexity and bizarreness. A mental blank during wakefulness was complete in six patients and partial in one patient. Four (31%) patients with auto-activation deficit (versus 92% of control subjects) reported mentations when awakened from REM sleep, even when they demonstrated a mental blank during the daytime (n = 2). However, the patients' dream reports were infrequent, short, devoid of any bizarre or emotional elements and tended to be less complex than the dream mentations of control subjects. The sleep duration, continuity and stages were similar between the groups, except for a striking absence of sleep spindles in 6 of 13 patients with auto-activation deficit, despite an intact thalamus. The presence of spontaneous dreams in REM sleep in the absence of thoughts during wakefulness in patients with auto-activation deficit supports the idea that simple dream imagery is generated by brainstem stimulation and is sent to the sensory cortex. However, the lack of complexity in these dream mentations suggests that the full dreaming process (scenario, emotions, etc.) require these sensations to be interpreted by higher-order cortical areas. The absence of sleep spindles in localized lesions in the basal ganglia highlights the role of the pallidum and striatum in spindling activity during non-REM sleep.
Chaudhri, Naeem A; Aljurf, Mahmoud; Almohareb, Fahad I; Alzahrani, Hazzaa A; Bashir, Qaiser; Savani, Bipin; Gupta, Vikas; Hashmi, Shahrukh K
2017-12-01
More than 70,000 hematopoietic cell transplants are currently performed each year, and these continue to increase every year. However, there is a significant variation in the number of absolute transplants and transplant rates between centers, countries, and global regions. The prospect for emerging countries to develop a hematopoietic cell transplantation (HCT) program, as well as to decide on whether autologous HCT (auto-HCT) or allogeneic HCT (allo-HCT) should be established to start with, relies heavily on factors that can explain differences between these two procedures. Major factors that will influence a decision about establishing the type of HCT program are macroeconomic factors such as organization of the healthcare network, available resources and infrastructure. Prevalence of specific diseases in the region as well genetic background of donors and recipients will also influence the mandate or priority of the HCT in the national healthcare plan to explain some of the country-specific differences. Furthermore, microeconomic factors play a role, such as center-specific experience in treating various disorders requiring hematopoietic stem cell transplantation, along with accreditation status and patient volume. The objective of the transplant procedure was to improve the survival and quality of life of patients. The regional difference that one notices in emerging countries about the higher number of allo-HCT compared with auto-HCT procedures performed is primarily based on suboptimal healthcare network in treating various malignant disorders that are the primary indication for auto-stem cell transplantation. In this context, nonmalignant disorders such as bone marrow failure syndromes, inherited genetic disorders and hemoglobinopathies have become the major indication for stem cell transplantation. Better understanding of these factors will assist in establishing new transplant centers in the emerging countries to achieve their specific objectives and positive outcome. Copyright © 2017. Published by Elsevier B.V.
Auto Indexer Auto-Indexer for Percussive Hammers: Vane Motor Dynamometer Testing
Su, Jiann
2012-01-01
Objectives Options associated with geothermal drilling operations are generally limited by factors such as formation temperature and rock strength. The objective of the research is to expand the "tool box" available to the geothermal driller by furthering the development of a high-temperature drilling motor that can be used in directional drilling applications for drilling high temperature geothermal formations. The motor is specifically designed to operate in conjunction with a pneumatic down-the-hole-hammer. It provides a more compact design compared to traditional drilling motors such as PDMs (positive displacement motors). The packaging can help to enhance directional drilling capabilities. It uses no elastomeric components, which enables it to operate in higher temperatures ( >250 °F). Current work on the motor has shown that is a capable of operating under pneumatic power with a down-the-hole-hammer. Further development work will include continued testing and refining motor components and evaluating motor capabilities. Targets/Milestones Complete testing current motor - 12/31/2010 Make final material and design decisions - 01/31/2011 Build and test final prototype - 04/31/2011 Final demonstration - 07/31/2011 Impacts The development of the motor will help to achieve program technical objectives by improving well construction capabilities. This includes enabling high-temperature drilling as well as enhancing directional drilling. A key component in the auto indexer is the drive motor. It is an air-driven vane motor that converts the energy stored in the compressed air to mechanical energy. The motor is attached to hammer-like components which impart an impulsive load onto the drive shaft. The impulsive force on the drive shaft in turn creates an indexing action. A controlled test was performed to characterize the performance of the the vane motor for a given pressure. The Sandia dynamometer test station was used to determine the performance of the motor for a given input pressure.
NASA Astrophysics Data System (ADS)
Gamadia, Mark Noel
In order to gain valuable market share in the growing consumer digital still camera and camera phone market, camera manufacturers have to continually add and improve existing features to their latest product offerings. Auto-focus (AF) is one such feature, whose aim is to enable consumers to quickly take sharply focused pictures with little or no manual intervention in adjusting the camera's focus lens. While AF has been a standard feature in digital still and cell-phone cameras, consumers often complain about their cameras' slow AF performance, which may lead to missed photographic opportunities, rendering valuable moments and events with undesired out-of-focus pictures. This dissertation addresses this critical issue to advance the state-of-the-art in the digital band-pass filter, passive AF method. This method is widely used to realize AF in the camera industry, where a focus actuator is adjusted via a search algorithm to locate the in-focus position by maximizing a sharpness measure extracted from a particular frequency band of the incoming image of the scene. There are no known systematic methods for automatically deriving the parameters such as the digital pass-bands or the search step-size increments used in existing passive AF schemes. Conventional methods require time consuming experimentation and tuning in order to arrive at a set of parameters which balance AF performance in terms of speed and accuracy ultimately causing a delay in product time-to-market. This dissertation presents a new framework for determining an optimal set of passive AF parameters, named Filter- Switching AF, providing an automatic approach to achieve superior AF performance, both in good and low lighting conditions based on the following performance measures (metrics): speed (total number of iterations), accuracy (offset from truth), power consumption (total distance moved), and user experience (in-focus position overrun). Performance results using three different prototype cameras are presented to further illustrate the real-world AF performance gains achieved by the developed approach. The major contribution of this dissertation is that the developed auto focusing approach can be successfully used by camera manufacturers in the development of the AF feature in future generations of digital still cameras and camera phones.
Yeap, P L; Noble, D J; Harrison, K; Bates, A M; Burnet, N G; Jena, R; Romanchikova, M; Sutcliffe, M P F; Thomas, S J; Barnett, G C; Benson, R J; Jefferies, S J; Parker, M A
2017-07-12
To determine delivered dose to the spinal cord, a technique has been developed to propagate manual contours from kilovoltage computed-tomography (kVCT) scans for treatment planning to megavoltage computed-tomography (MVCT) guidance scans. The technique uses the Elastix software to perform intensity-based deformable image registration of each kVCT scan to the associated MVCT scans. The registration transform is then applied to contours of the spinal cord drawn manually on the kVCT scan, to obtain contour positions on the MVCT scans. Different registration strategies have been investigated, with performance evaluated by comparing the resulting auto-contours with manual contours, drawn by oncologists. The comparison metrics include the conformity index (CI), and the distance between centres (DBC). With optimised registration, auto-contours generally agree well with manual contours. Considering all 30 MVCT scans for each of three patients, the median CI is [Formula: see text], and the median DBC is ([Formula: see text]) mm. An intra-observer comparison for the same scans gives a median CI of [Formula: see text] and a DBC of ([Formula: see text]) mm. Good levels of conformity are also obtained when auto-contours are compared with manual contours from one observer for a single MVCT scan for each of 30 patients, and when they are compared with manual contours from six observers for two MVCT scans for each of three patients. Using the auto-contours to estimate organ position at treatment time, a preliminary study of 33 patients who underwent radiotherapy for head-and-neck cancers indicates good agreement between planned and delivered dose to the spinal cord.
NASA Astrophysics Data System (ADS)
Yeap, P. L.; Noble, D. J.; Harrison, K.; Bates, A. M.; Burnet, N. G.; Jena, R.; Romanchikova, M.; Sutcliffe, M. P. F.; Thomas, S. J.; Barnett, G. C.; Benson, R. J.; Jefferies, S. J.; Parker, M. A.
2017-08-01
To determine delivered dose to the spinal cord, a technique has been developed to propagate manual contours from kilovoltage computed-tomography (kVCT) scans for treatment planning to megavoltage computed-tomography (MVCT) guidance scans. The technique uses the Elastix software to perform intensity-based deformable image registration of each kVCT scan to the associated MVCT scans. The registration transform is then applied to contours of the spinal cord drawn manually on the kVCT scan, to obtain contour positions on the MVCT scans. Different registration strategies have been investigated, with performance evaluated by comparing the resulting auto-contours with manual contours, drawn by oncologists. The comparison metrics include the conformity index (CI), and the distance between centres (DBC). With optimised registration, auto-contours generally agree well with manual contours. Considering all 30 MVCT scans for each of three patients, the median CI is 0.759 +/- 0.003 , and the median DBC is (0.87 +/- 0.01 ) mm. An intra-observer comparison for the same scans gives a median CI of 0.820 +/- 0.002 and a DBC of (0.64 +/- 0.01 ) mm. Good levels of conformity are also obtained when auto-contours are compared with manual contours from one observer for a single MVCT scan for each of 30 patients, and when they are compared with manual contours from six observers for two MVCT scans for each of three patients. Using the auto-contours to estimate organ position at treatment time, a preliminary study of 33 patients who underwent radiotherapy for head-and-neck cancers indicates good agreement between planned and delivered dose to the spinal cord.
ERIC Educational Resources Information Center
Jacobs, Jim
2013-01-01
Just as good community colleges pivot to mirror the needs of their local communities, the multistate Auto Communities Consortium (ACC) continues to evolve to counteract the challenges encountered by employers in its service region. Established in 2010 to address pervasive economic losses faced by communities whose major employers were auto…
Modest Labor-Management Bargains Continue in 1984 Despite the Recovery.
ERIC Educational Resources Information Center
Ruben, George
1985-01-01
Major collective bargaining agreements in 1984 resulted in modest settlements, due to concern about foreign competition, domestic deregulation, and inflation. Agreements occurred in the following industries: auto, soft coal, airlines, aircraft and aerospace, construction, petroleum refining, longshore industry, railroads, trucking, steel, West…
Htut, Myo; D'Souza, Anita; Krishnan, Amrita; Bruno, Benedetto; Zhang, Mei-Jie; Fei, Mingwei; Diaz, Miguel Angel; Copelan, Edward; Ganguly, Siddhartha; Hamadani, Mehdi; Kharfan-Dabaja, Mohamed; Lazarus, Hillard; Lee, Cindy; Meehan, Kenneth; Nishihori, Taiga; Saad, Ayman; Seo, Sachiko; Ramanathan, Muthalagu; Usmani, Saad Z; Gasparetto, Christina; Mark, Tomer M; Nieto, Yago; Hari, Parameswaran
2018-03-01
We compared postrelapse overall survival (OS) after autologous/allogeneic (auto/allo) versus tandem autologous (auto/auto) hematopoietic cell transplantation (HCT) in patients with multiple myeloma (MM). Postrelapse survival of patients receiving an auto/auto or auto/allo HCT for MM and prospectively reported to the Center for International Blood and Marrow Transplant Research between 2000 and 2010 were analyzed. Relapse occurred in 404 patients (72.4%) in the auto/auto group and in 178 patients (67.4%) in the auto/allo group after a median follow-up of 8.5 years. Relapse occurred before 6 months after a second HCT in 46% of the auto/allo patients, compared with 26% of the auto/auto patients. The 6-year postrelapse survival was better in the auto/allo group compared with the auto/auto group (44% versus 35%; P = .05). Mortality due to MM was 69% (n = 101) in the auto/allo group and 83% (n = 229) deaths in auto/auto group. In multivariate analysis, both cohorts had a similar risk of death in the first year after relapse (hazard ratio [HR], .72; P = .12); however, for time points beyond 12 months after relapse, overall survival was superior in the auto/allo cohort (HR for death in auto/auto =1.55; P = .005). Other factors associated with superior survival were enrollment in a clinical trial for HCT, male sex, and use of novel agents at induction before HCT. Our findings shown superior survival afterrelapse in auto/allo HCT recipients compared with auto/auto HCT recipients. This likely reflects a better response to salvage therapy, such as immunomodulatory drugs, potentiated by a donor-derived immunologic milieu. Further augmentation of the post-allo-HCT immune system with new immunotherapies, such as monoclonal antibodies, checkpoint inhibitors, and others, merit investigation. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
RESEARCH PROJECT A: MAPPING DISPARITIES IN BIRTH OUTCOMES
Jin, Yinji; Jin, Taixian; Lee, Sun-Mi
Pressure injury risk assessment is the first step toward preventing pressure injuries, but traditional assessment tools are time-consuming, resulting in work overload and fatigue for nurses. The objectives of the study were to build an automated pressure injury risk assessment system (Auto-PIRAS) that can assess pressure injury risk using data, without requiring nurses to collect or input additional data, and to evaluate the validity of this assessment tool. A retrospective case-control study and a system development study were conducted in a 1,355-bed university hospital in Seoul, South Korea. A total of 1,305 pressure injury patients and 5,220 nonpressure injury patients participated for the development of a risk scoring algorithm: 687 and 2,748 for the validation of the algorithm and 237 and 994 for validation after clinical implementation, respectively. A total of 4,211 pressure injury-related clinical variables were extracted from the electronic health record (EHR) systems to develop a risk scoring algorithm, which was validated and incorporated into the EHR. That program was further evaluated for predictive and concurrent validity. Auto-PIRAS, incorporated into the EHR system, assigned a risk assessment score of high, moderate, or low and displayed this on the Kardex nursing record screen. Risk scores were updated nightly according to 10 predetermined risk factors. The predictive validity measures of the algorithm validation stage were as follows: sensitivity = .87, specificity = .90, positive predictive value = .68, negative predictive value = .97, Youden index = .77, and the area under the receiver operating characteristic curve = .95. The predictive validity measures of the Braden Scale were as follows: sensitivity = .77, specificity = .93, positive predictive value = .72, negative predictive value = .95, Youden index = .70, and the area under the receiver operating characteristic curve = .85. The kappa of the Auto-PIRAS and Braden Scale risk classification result was .73. The predictive performance of the Auto-PIRAS was similar to Braden Scale assessments conducted by nurses. Auto-PIRAS is expected to be used as a system that assesses pressure injury risk automatically without additional data collection by nurses.
%;position:relative;z-index:1}.noUi-connects{overflow:hidden;z-index:0}.noUi-connect,.noUi-origin{will -change:transform;position:absolute;z-index:1;top:0;left:0;height:100%;width:100%;-webkit-transform-origin:0 0 ;transform-origin:0 0}html:not([dir=rtl]) .noUi-horizontal .noUi-origin{left:auto;right:0}.noUi-vertical
Doctorate Motivation: An (Auto)ethnography
ERIC Educational Resources Information Center
Templeton, Robert
2016-01-01
Intrinsic motivation is considered the dominant factor in the motivation of adult students in continuing postgraduate education. However, the strength of an intrinsic motivation to learn does not explain the phenomenon of dropout where the student withdraws and does not return or where the student withdraws and then recommences their postgraduate…
Krishnan, Amrita; Pasquini, Marcelo C.; Logan, Brent; Stadtmauer, Edward A.; Vesole, David H.; Alyea, Edwin; Antin, Joseph H.; Comenzo, Raymond; Goodman, Stacey; Hari, Parameswaran; Laport, Ginna; Qazilbash, Muzaffar H.; Rowley, Scott; Sahebi, Firoozeh; Somlo, George; Vogl, Dan T.; Weisdorf, Daniel; Ewell, Marian; Wu, Juan; Geller, Nancy L.; Horowitz, Mary M.; Giralt, Sergio; Maloney, David G.
2012-01-01
Background Autologous hematopoietic cell transplantation (HCT) improves survival in patients with multiple myeloma, but disease progression remains a challenge. Allogeneic HCT (alloHCT) has the potential to reduce disease progression through graft-versus-myeloma effects. The aim of the BMT CTN 0102 trial was to compare outcomes of autologous HCT (autoHCT) followed by alloHCT with non-myeloablative conditioning (auto-allo) to tandem autoHCT (auto-auto) in patients with standard risk myeloma. Patients in the auto-auto arm were randomized to one year of thalidomide and dexamethasone (Thal-Dex) maintenance therapy or observation (Obs). Methods Patients with multiple myeloma within 10 months from initiation of induction therapy were classified as standard (SRD) or high risk (HRD) disease based on cytogenetics and beta-2-microglobulin levels. Assignment to auto-allo HCT was based on availability of an HLA-matched sibling donor. Primary endpoint was three-year progression-free survival (PFS) according to intent-to-treat analysis. Results 710 patients were enrolled completed a minimum of 3-year follow up. Among 625 SRD patients, 189 and 436 were assigned to auto-allo and auto-auto, respectively. Seventeen percent (33/189) of SR patients in the auto-allo arm and 16% (70/436) in the auto-auto arm did not receive a second transplant. Thal-Dex was not completed in 77% (168/217) of assigned patients. PFS and overall survival (OS) did not differ between the Thal-Dex (49%, 80%) and Obs (41%, 81%) cohorts and these two arms were pooled for analysis. Three year PFS was 43% and 46% (p=0·671) and three-year OS was 77% and 80 % (p=0·191) with auto-allo and auto-auto, respectively. Corresponding progression/relapse rates were 46% and 50% (p=0·402); treatment-related mortality rates were 11% and 4% (p<0·001), respectively. Auto/allo patients with chronic graft-vs-host disease had a decreased risk of relapse. Most common grade 3 to 5 adverse events in auto-allo was hypebilirubenemia (21/189) and in the auto-auto was peripheral neuropathy (52/436). Among 85 HRD patients (37 auto-allo), three PFS was 40% and 33% (p=0·743) and three-year OS was 59% and 67% (p=0·460) with auto-allo and auto-auto, respectively. Conclusion Thal-Dex maintenance was associated with poor compliance and did not improve PFS or OS. At three years there was no improvement in PFS or OS with auto-allo compared to auto-auto transplantation in patients with standard risk myeloma. Decisions to proceed with alloHCT after an autoHCT in patients with standard risk myeloma should take into consideration results of the current trial. Future investigation of alloHCT in myeloma should focus to minimize TRM and maximize graft-versus myeloma effects. This trial was registered in Clinicaltrials.gov (NCT00075829) and was funded by the National Heart, Lung and Blood Institute and National Cancer Institute. PMID:21962393
An IRT Model with a Parameter-Driven Process for Change
ERIC Educational Resources Information Center
Rijmen, Frank; De Boeck, Paul; van der Maas, Han L. J.
2005-01-01
An IRT model with a parameter-driven process for change is proposed. Quantitative differences between persons are taken into account by a continuous latent variable, as in common IRT models. In addition, qualitative inter-individual differences and auto-dependencies are accounted for by assuming within-subject variability with respect to the…
Forging a Research Pathway: Perspectives of Two Post-Tenure Female Faculty Members
ERIC Educational Resources Information Center
McIntyre, Laureen J.; Hellsten, Laurie-Ann M.
2014-01-01
This paper presents an auto-ethnographic exploration of two post-tenure female faculty member's experiences developing their programs of research. Self-reflection was used to explore the factors that have helped or hindered the development of their research program, and the continued challenges they faced as female faculty. Composite themes were…
Zhu, Jingbo; Liu, Baoyue; Shan, Shibo; Ding, Yanl; Kou, Zinong; Xiao, Wei
2015-08-01
In order to meet the needs of efficient purification of products from natural resources, this paper developed an automatic vacuum liquid chromatographic device (AUTO-VLC) and applied it to the component separation of petroleum ether extracts of Schisandra chinensis (Turcz) Baill. The device was comprised of a solvent system, a 10-position distribution valve, a 3-position changes valve, dynamic axis compress chromatographic columns with three diameters, and a 10-position fraction valve. The programmable logic controller (PLC) S7- 200 was adopted to realize the automatic control and monitoring of the mobile phase changing, column selection, separation time setting and fraction collection. The separation results showed that six fractions (S1-S6) of different chemical components from 100 g Schisandra chinensis (Turcz) Baill. petroleum ether phase were obtained by the AUTO-VLC with 150 mm diameter dynamic axis compress chromatographic column. A new method used for the VLC separation parameters screened by using multiple development TLC was developed and confirmed. The initial mobile phase of AUTO-VLC was selected by taking Rf of all the target compounds ranging from 0 to 0.45 for fist development on the TLC; gradient elution ratio was selected according to k value (the slope of the linear function of Rf value and development times on the TLC) and the resolution of target compounds; elution times (n) were calculated by the formula n ≈ ΔRf/k. A total of four compounds with the purity more than 85% and 13 other components were separated from S5 under the selected conditions for only 17 h. Therefore, the development of the automatic VLC and its method are significant to the automatic and systematic separation of traditional Chinese medicines.
NASA Technical Reports Server (NTRS)
Ioup, George E.; Ioup, Juliette W.
1988-01-01
This thesis reviews the technique established to clear channels in the Power Spectral Estimate by applying linear combinations of well known window functions to the autocorrelation function. The need for windowing the auto correlation function is due to the fact that the true auto correlation is not generally used to obtain the Power Spectral Estimate. When applied, the windows serve to reduce the effect that modifies the auto correlation by truncating the data and possibly the autocorrelation has on the Power Spectral Estimate. It has been shown in previous work that a single channel has been cleared, allowing for the detection of a small peak in the presence of a large peak in the Power Spectral Estimate. The utility of this method is dependent on the robustness of it on different input situations. We extend the analysis in this paper, to include clearing up to three channels. We examine the relative positions of the spikes to each other and also the effect of taking different percentages of lags of the auto correlation in the Power Spectral Estimate. This method could have application wherever the Power Spectrum is used. An example of this is beam forming for source location, where a small target can be located next to a large target. Other possibilities extend into seismic data processing. As the method becomes more automated other applications may present themselves.
Coogan, Matthew A; Karash, Karla H; Adler, Thomas; Sallis, James
2007-01-01
To examine the association of personal values, the built environment, and auto availability with walking for transportation. Participants were drawn from 11 U.S. metropolitan areas with good transit services. 865 adults who had recently made or were contemplating making a residential move. Respondents reported if walking was their primary mode for nine trip purposes. "Personal values" reflected ratings of 15 variables assessing attitudes about urban and environmental attributes, with high reliability (ot = 0.85). Neighborhood form was indicated by a three-item scale. Three binary variables were created to reflect (1) personal values, (2) neighborhood form, and (3) auto availability. The association with walking was reported for each of the three variables, each combination of two variables, and the combination of three variables. An analysis of covariance was applied, and a hierarchic linear regression model was developed. All three variables were associated with walking, and all three variables interacted. The standardized coefficients were 0.23for neighborhood form, 0.21 for autos per person, and 0.18 for personal values. Positive attitudes about urban attributes, living in a supportive neighborhood, and low automobile availability significantly predicted more walking for transportation. A framework for further research is proposed in which a factor representing the role of the automobile is examined explicitly in addition to personal values and urban form.
Zenitani, Satoko; Nishiuchi, Hiromu; Kiuchi, Takahiro
2010-04-01
The Smart-card-based Automatic Meal Record system for company cafeterias (AutoMealRecord system) was recently developed and used to monitor employee eating habits. The system could be a unique nutrition assessment tool for automatically monitoring the meal purchases of all employees, although it only focuses on company cafeterias and has never been validated. Before starting an interventional study, we tested the reliability of the data collected by the system using the data mining approach. The AutoMealRecord data were examined to determine if it could predict current obesity. All data used in this study (n = 899) were collected by a major electric company based in Tokyo, which has been operating the AutoMealRecord system for several years. We analyzed dietary patterns by principal component analysis using data from the system and extracted 5 major dietary patterns: healthy, traditional Japanese, Chinese, Japanese noodles, and pasta. The ability to predict current body mass index (BMI) with dietary preference was assessed with multiple linear regression analyses, and in the current study, BMI was positively correlated with male gender, preference for "Japanese noodles," mean energy intake, protein content, and frequency of body measurement at a body measurement booth in the cafeteria. There was a negative correlation with age, dietary fiber, and lunchtime cafeteria use (R(2) = 0.22). This regression model predicted "would-be obese" participants (BMI >or= 23) with 68.8% accuracy by leave-one-out cross validation. This shows that there was sufficient predictability of BMI based on data from the AutoMealRecord System. We conclude that the AutoMealRecord system is valuable for further consideration as a health care intervention tool. Copyright 2010 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Gu, L.
2017-12-01
In this study, we examine responses of sun-induced chlorophyll fluorescence to biological and environmental variations measured with a versatile Fluorescence Auto-Measurement Equipment (FAME). FAME was developed to automatically and continuously measure chlorophyll fluorescence (F) of a leaf, plant or canopy in both laboratory and field environments, excited by either artificial light source or sunlight. FAME is controlled by a datalogger and allows simultaneous measurements of environmental variables complementary to the F signals. A built-in communication system allows FAME to be remotely monitored and data-downloaded. Radiance and irradiance calibrations can be done online. FAME has been applied in a variety of environments, allowing an investigation of biological and environmental controls on F emission.
2013-01-01
Background Quadriplegia is a severe, catastrophic injury that predominantly affects people early in life, resulting in lifelong physical disability. Obstructive sleep apnoea is a direct consequence of quadriplegia and is associated with neurocognitive deficits, sleepiness and reduced quality of life. The usual treatment for sleep apnoea is nasal continuous positive airway pressure (CPAP); however, this is poorly tolerated in quadriplegia. To encourage patients to use this therapy, we have to demonstrate that the benefits outweigh the inconvenience. We therefore propose a prospective, multinational randomized controlled trial of three months of CPAP for obstructive sleep apnoea after acute quadriplegia. Methods/design Specialist spinal cord injury centres across Australia, New Zealand, the UK and Canada will recruit medically stable individuals who have sustained a (new) traumatic quadriplegia (complete or incomplete second cervical to first thoracic level lesions). Participants will be screened for obstructive sleep apnoea using full, portable sleep studies. Those with an apnoea hypopnoea index greater than 10 per hour will proceed to an initial three-night trial of CPAP. Those who can tolerate CPAP for at least 4 hours on at least one night of the initial trial will be randomized to either usual care or a 3-month period of auto-titrating CPAP. The primary hypothesis is that nocturnal CPAP will improve neuropsychological functioning more than usual care alone. The secondary hypothesis is that the magnitude of improvement of neuropsychological function will be predicted by the severity of baseline sleepiness measures, sleep fragmentation and sleep apnoea. Neuropsychological tests and full polysomnography will be performed at baseline and 3 months with interim measures of sleepiness and symptoms of autonomic dysfunction measured weekly. Spirometry will be performed monthly. Neuropsychological tests will be administered by blinded assessors. Recruitment commenced in July 2009. Discussion The results of this trial will demonstrate the effect of nocturnal CPAP treatment of obstructive sleep apnoea in acute quadriplegia. If CPAP can improve neurocognitive function after injury, it is likely that rehabilitation and subsequent community participation will be substantially improved for this group of predominantly young and severely physically disabled people. Trial registration Australian New Zealand Clinical Trial Registry ACTRN12605000799651 PMID:23777510
Natalini, Giuseppe; Tuzzo, Daniele; Rosano, Antonio; Testa, Marco; Grazioli, Michele; Pennestrì, Vincenzo; Amodeo, Guido; Berruto, Francesco; Fiorillo, Marialinda; Peratoner, Alberto; Tinnirello, Andrea; Filippini, Matteo; Marsilia, Paolo F; Minelli, Cosetta; Bernardini, Achille
2016-12-01
In some patients with auto-positive end-expiratory pressure (auto-PEEP), application of PEEP lower than auto-PEEP maintains a constant total PEEP, therefore reducing the inspiratory threshold load without detrimental cardiovascular or respiratory effects. We refer to these patients as "complete PEEP-absorbers." Conversely, adverse effects of PEEP application could occur in patients with auto-PEEP when the total PEEP rises as a consequence. From a pathophysiological perspective, all subjects with flow limitation are expected to be "complete PEEP-absorbers," whereas PEEP should increase total PEEP in all other patients. This study aimed to empirically assess the extent to which flow limitation alone explains a "complete PEEP-absorber" behavior (i.e., absence of further hyperinflation with PEEP), and to identify other factors associated with it. One hundred patients with auto-PEEP of at least 5 cmH2O at zero end-expiratory pressure (ZEEP) during controlled mechanical ventilation were enrolled. Total PEEP (i.e., end-expiratory plateau pressure) was measured both at ZEEP and after applied PEEP equal to 80 % of auto-PEEP measured at ZEEP. All measurements were repeated three times, and the average value was used for analysis. Forty-seven percent of the patients suffered from chronic pulmonary disease and 52 % from acute pulmonary disease; 61 % showed flow limitation at ZEEP, assessed by manual compression of the abdomen. The mean total PEEP was 7 ± 2 cmH2O at ZEEP and 9 ± 2 cmH2O after the application of PEEP (p < 0.001). Thirty-three percent of the patients were "complete PEEP-absorbers." Multiple logistic regression was used to predict the behavior of "complete PEEP-absorber." The best model included a respiratory rate lower than 20 breaths/min and the presence of flow limitation. The predictive ability of the model was excellent, with an overoptimism-corrected area under the receiver operating characteristics curve of 0.89 (95 % CI 0.80-0.97). Expiratory flow limitation was associated with both high and complete "PEEP-absorber" behavior, but setting a relatively high respiratory rate on the ventilator can prevent from observing complete "PEEP-absorption." Therefore, the effect of PEEP application in patients with auto-PEEP can be accurately predicted at the bedside by measuring the respiratory rate and observing the flow-volume loop during manual compression of the abdomen.
Krakow, Barry J; Obando, Jessica J; Ulibarri, Victor A; McIver, Natalia D
2017-01-01
Study objectives Patients with comorbid posttraumatic stress disorder (PTSD) and obstructive sleep apnea (OSA) manifest low adherence to continuous positive airway pressure (CPAP) due to fixed, pressure-induced expiratory pressure intolerance (EPI), a subjective symptom and objective sign aggravated by anxiety sensitivity and somatosensory amplification. As advanced PAP therapy modes (ie, auto-bilevel PAP [ABPAP] or adaptive servo-ventilation [ASV]) may address these side effects, we hypothesized such treatment would be associated with decreased expiratory intolerance and increased adherence in posttraumatic stress patients with co-occurring OSA. Methods We reviewed charts of 147 consecutive adult patients with moderately severe posttraumatic stress symptoms and objectively diagnosed OSA. All patients failed or rejected CPAP and were manually titrated on auto-adjusting, dual-pressure ABPAP or ASV modes in the sleep laboratory, a technique to eliminate flow limitation breathing events while resolving EPI. Patients were then prescribed either mode of therapy. Follow-up encounters assessed patient use, and objective data downloads (ODDs) measured adherence. Results Of 147 charts reviewed, 130 patients were deemed current PAP users, and 102 provided ODDs: 64 used ASV and 38 used ABPAP. ODDs yielded three groups: 59 adherent per insurance conventions, 19 subthreshold compliant partial users, and 24 noncompliant. Compliance based on available downloads was 58%, notably higher than recently reported rates in PTSD patients with OSA. Among the 19 partial users, 17 patients were minutes of PAP use or small percentages of nights removed from meeting insurance compliance criteria for PAP devices. Conclusion Research is warranted on advanced PAP modes in managing CPAP failure in PTSD patients with comorbid OSA. Subthreshold adherence constructs may inform clinical care in a patient-centric model distinct from insurance conventions. Speculatively, clinical application of this transitional zone (“subthreshold” number of hours) may increase PAP use and eventual adherence. PMID:29200833
[Anti-M3 muscarinic acetylcholine receptor antibodies and Sjögren's syndrome].
Tsuboi, Hiroto; Iizuka, Mana; Asashima, Hiromitsu; Sumida, Takayuki
2013-01-01
Sjögren's syndrome (SS) is an autoimmune disease that affects exocrine glands including salivary and lacrimal glands. It is characterized by lymphocytic infiltration into exocrine glands, leading to dry mouth and eyes. A number of auto-antibodies are detected in patients with SS. However, no SS-specific pathologic auto-antibodies have yet been found in this condition. M3 muscarinic acetylcholine receptor (M3R) plays a crucial role in the secretion of saliva. It is reported that some patients with SS carried inhibitory auto-antibodies against M3R. To clarify the epitopes and function of anti-M3R antibodies in SS, we examined antibodies to the extracellular domains (N terminal region, the first, second, and third extracellular loop) of M3R by ELISA using synthesized peptide antigens encoding these domains in 42 SS and 42 healthy controls (HC). Titers and positivity of anti-M3R antibodies to every extracellular domain of M3R were significantly higher in SS than in HC. Our results indicated the presence of several B cell epitopes on M3R in SS. Moreover, we analyzed the functions of anti-M3R antibodies by Ca(2+)-influx assays using a human salivary gland (HSG) cell line. The functional analysis indicated that the influence of such anti-M3R antibodies on Ca(2+)-influx in HSG cells might differ based on the epitopes to which they bind. Interestingly, both IgG from anti-M3R antibodies to the second extracellular loop positive SS and anti-M3R monoclonal antibodies against the second extracellular loop of M3R, which we generated, suppressed Ca(2+)-influx in the HSG cells induced by cevimeline stimulation. These observations suggested that auto-antibodies against the second extracellular loop of M3R could be involved in salivary dysfunction in patients with SS. These results indicated the presence of several B cell epitopes on M3R in SS and the influence of anti-M3R antibodies on salivary secretion might differ based on these epitopes. Thus, anti-M3R antibodies could be not only potential pathologic auto-antibodies, but also new diagnostic makers and therapeutic targets for SS.
Myocarditis in auto-immune or auto-inflammatory diseases.
Comarmond, Cloé; Cacoub, Patrice
2017-08-01
Myocarditis is a major cause of heart disease in young patients and a common precursor of heart failure due to dilated cardiomyopathy. Some auto-immune and/or auto-inflammatory diseases may be accompanied by myocarditis, such as sarcoidosis, Behçet's disease, eosinophilic granulomatosis with polyangiitis, myositis, and systemic lupus erythematosus. However, data concerning myocarditis in such auto-immune and/or auto-inflammatory diseases are sparse. New therapeutic strategies should better target the modulation of the immune system, depending on the phase of the disease and the type of underlying auto-immune and/or auto-inflammatory disease. Copyright © 2017 Elsevier B.V. All rights reserved.
Auto Service Career Preparation Moves to the Fast Track.
ERIC Educational Resources Information Center
Gray, Don
2000-01-01
Automotive Youth Educational Systems (AYES) is a school-to-career partnership among automotive manufacturers and dealers and selected high schools. AYES is designed to encourage students to consider careers in retail automotive service and to prepare them for entry-level positions at dealerships or colleges. (JOW)
NOVEL STATISTICAL APPROACH TO EVALUATE SPATIAL DISTRIBUTION OF PM FROM SPECIFIC SOURCE CATEGORIES
This task addresses aspects of NRC recommendations 10A and 10B. Positive matrix factorization (PMF) is a new statistical techniques for determining the daily contribution to PM mass of specific source categories (auto exhaust, smelters, suspended soil, secondary sulfate, etc.). I...
Relationship between Applicant Handicap and Employment Evaluations.
ERIC Educational Resources Information Center
Farrow, Dana L.; And Others
Very little is known about discrimination against the handicapped in employment situations and the processes by which it occurs. Mature students (N=72) in personnel and behavioral science courses evaluated epileptic or non-epileptic, male or female applicants for an auto sales or receptionist position. Subjects reviewed an applicant's resume…
NASA Astrophysics Data System (ADS)
Jensen, J. B.; Schwenz, K.; Aquino, J.; Carnes, J.; Webster, C.; Munnerlyn, J.; Wissman, T.; Lugger, T.
2017-12-01
Giant sea-salt aerosol particles, also called Giant Cloud Condensation Nuclei (GCCN), have been proposed as a means of rapidly forming precipitation sized drizzle drops in warm marine clouds (e.g., Jensen and Nugent, 2017). Such rare particles are best sampled from aircraft in air below cloud base, where normal laser optical instruments have too low sample volume to give statistically significant samples of the large particle tail. An automated sampling system (the AutoGNI) has been built to operate from inside a pressurized aircraft. Under the aircraft floor, a pressurized vessel contains 32 custom-built polycarbonate microscope slides. Using robotics with 5 motor drives and 18 positioning switches, the AutoGNI can take slides from their holding cassettes, pass them onto a caddy in an airfoil that extends 200 mm outside the aircraft, where they are exposed in the free airstream, thus avoiding the usual problems with large particle losses in air intakes. Slides are typically exposed for 10-30 s in the marine boundary layer, giving sample volumes of about 100-300 L or more. Subsequently the slides are retracted into the pressure vessel, stored and transported for laboratory microscope image analysis, in order to derive size-distribution histograms. While the aircraft is flying, the AutoGNI system is remotely controlled from a laptop on the ground, using an encrypted commercial satellite connection to the NSF/NCAR GV research aircraft's main server, and onto the AutoGNI microprocessor. The sampling of such GCCN is becoming increasingly important in order to provide complete input data for model calculations of aerosol-cloud interactions and their feedbacks in climate prediction. The AutoGNI has so far been sampling sea-salt GCCN in the Magellan Straight during the 2016 ORCAS project and over the NW Pacific during the 2017 ARISTO project, both from the NSF/NCAR GV research aircraft. Sea-salt particle sizes of 1.4 - 32 μm dry diameter have been observed.
Khot, Sandeep P.; Davis, Arielle P.; Crane, Deborah A.; Tanzi, Patricia M.; Li Lue, Denise; Claflin, Edward S.; Becker, Kyra J.; Longstreth, W.T.; Watson, Nathaniel F.; Billings, Martha E.
2016-01-01
Study Objectives: Obstructive sleep apnea (OSA) predicts poor functional outcome after stroke and increases the risk for recurrent stroke. Less is known about continuous positive airway pressure (CPAP) treatment on stroke recovery. Methods: In a pilot randomized, double-blind, sham-controlled trial, adult stroke rehabilitation patients were assigned to auto-titrating or sham CPAP without diagnostic testing for OSA. Change in Functional Independence Measure (FIM), a measure of disability, was assessed between rehabilitation admission and discharge. Results: Over 18 months, 40 patients were enrolled and 10 withdrew from the study: 7 from active and 3 from sham CPAP (p > 0.10). For the remaining 30 patients, median duration of CPAP use was 14 days. Average CPAP use was 3.7 h/night, with at least 4 h nightly use among 15 patients. Adherence was not influenced by treatment assignment or stroke severity. In intention-to-treat analyses (n = 40), the median change in FIM favored active CPAP over sham but did not reach statistical significance (34 versus 26, p = 0.25), except for the cognitive component (6 versus 2.5, p = 0.04). The on-treatment analyses (n = 30) yielded similar results (total FIM: 32 versus 26, p = 0.11; cognitive FIM: 6 versus 2, p = 0.06). Conclusions: A sham-controlled CPAP trial among stroke rehabilitation patients was feasible in terms of recruitment, treatment without diagnostic testing and adequate blinding—though was limited by study retention and CPAP adherence. Despite these limitations, a trend towards a benefit of CPAP on recovery was evident. Tolerance and adherence must be improved before the full benefits of CPAP on recovery can be assessed in larger trials. Citation: Khot SP, Davis AP, Crane DA, Tanzi PM, Li Lue D, Claflin ES, Becker KJ, Longstreth WT, Watson NF, Billings ME. Effect of continuous positive airway pressure on stroke rehabilitation: a pilot randomized sham-controlled trial. J Clin Sleep Med 2016;12(7):1019–1026. PMID:27092703
Comparisons of fully automated syphilis tests with conventional VDRL and FTA-ABS tests.
Choi, Seung Jun; Park, Yongjung; Lee, Eun Young; Kim, Sinyoung; Kim, Hyon-Suk
2013-06-01
Serologic tests are widely used for the diagnosis of syphilis. However, conventional methods require well-trained technicians to produce reliable results. We compared automated nontreponemal and treponemal tests with conventional methods. The HiSens Auto Rapid Plasma Reagin (AutoRPR) and Treponema Pallidum particle agglutination (AutoTPPA) tests, which utilize latex turbidimetric immunoassay, were assessed. A total of 504 sera were assayed by AutoRPR, AutoTPPA, conventional VDRL and FTA-ABS. Among them, 250 samples were also tested by conventional TPPA. The concordance rate between the results of VDRL and AutoRPR was 67.5%, and 164 discrepant cases were all VDRL reactive but AutoRPR negative. In the 164 cases, 133 showed FTA-ABS reactivity. Medical records of 106 among the 133 cases were reviewed, and 82 among 106 specimens were found to be collected from patients already treated for syphilis. The concordance rate between the results of AutoTPPA and FTA-ABS was 97.8%. The results of conventional TPPA and AutoTPPA for 250 samples were concordant in 241 cases (96.4%). AutoRPR showed higher specificity than that of VDRL, while VDRL demonstrated higher sensitivity than that of AutoRPR regardless of whether the patients had been already treated for syphilis or not. Both FTA-ABS and AutoTPPA showed high sensitivities and specificities greater than 98.0%. Automated RPR and TPPA tests could be alternatives to conventional syphilis tests, and AutoRPR would be particularly suitable in treatment monitoring, since results by AutoRPR in cases after treatment became negative more rapidly than by VDRL. Copyright © 2013. Published by Elsevier Inc.
Erdemir, A; Eldeniz, A U; Ari, H; Belli, S; Esener, T
2007-05-01
To determine the influence of various irrigating solutions on the accuracy of the electronic apex locator facility in the Tri Auto ZX handpiece. One hundred and forty teeth with single canals and mature apices, scheduled for extraction for either periodontal or prosthetic reasons in 76 patients were used. Following informed written consent local anaesthesia was administered, access cavities were prepared and pulp tissue removed. The teeth were then randomly divided into seven groups according to the irrigating solutions used. The root canal length measurements were completed using the Tri Auto ZX handpiece with automatic reverse function in the presence of one or other of the following solutions: 0.9% saline, 2.5% NaOCl, 3% H(2)O(2), 0.2% chlorhexidine, 17% EDTA, Ultracaine D-S or in the absence of an irrigating solution (control). Files were immobilized in the access cavity with composite resin. After extraction, the apical regions of the teeth were exposed and the file tips examined under a stereomicroscope. Distances between the file tips and the apical constriction were measured (mm) and analysed using a one-way anova and post hoc Tukey test. Mean distances from the apical constriction to the file tip were longer in the 0.9% saline group (P<0.05). There was no statistically significant difference on file tip position between the other solutions. Tri Auto ZX gave reliable results with all irrigating solutions apart from in the presence of 0.9% saline.
[Evaluation of exposure of auto painters to organic solvents in the city of Bogota].
Palma, Marien; Briceño, Leonardo; Idrovo, Álvaro J; Varona, Marcela
2015-08-01
Painters of automobiles are exposed to pure and mixed solvents that have been associated with neurological effects and carcinogenic mutations. To characterize the health and work conditions of individuals who are occupationally exposed to organic solvents used in sheet metal and auto body shops in Bogota. Descriptive, cross-sectional study that characterizes the health and work conditions of individuals exposed to organic solvents in sheet metal and auto body shops in Bogota. A group exposed to the solvents was compared to an unexposed group. Air concentrations of benzene, toluene and xylene (BTX) were determined, individual questionnaires were administered and phenylmercapturic, hippuric and ortho- and para-methylhippuric acids were measured in urine. The results of the measurements and the questionnaires were correlated to determine the exposure panorama. For the three BTX metabolites, statistically significant differences (p<0.001) were found between the population exposed to the solvents and the unexposed population. For the exposed population, positive correlations were found between toluene in air and hippuric acid in urine (rho=0.82) and between xylene in air and o-methylhippuric acid in urine (rho=0.76). Hippuric acid values exceeded permissible levels in 11 workers and p-methylhippuric acid exceeded permissible levels in 8 workers. None of the phenylmercapturic values exceeded the limit. Auto painters are exposed to high levels of organic solvents at the workplace and do not have adequate industrial health and safety conditions to perform their jobs.
Criterion-Referenced Test Items for Auto Body.
ERIC Educational Resources Information Center
Tannehill, Dana, Ed.
This test item bank on auto body repair contains criterion-referenced test questions based upon competencies found in the Missouri Auto Body Competency Profile. Some test items are keyed for multiple competencies. The tests cover the following 26 competency areas in the auto body curriculum: auto body careers; measuring and mixing; tools and…
Encouraging CPAP adherence: it is everyone's job.
Bollig, Suzanne M
2010-09-01
Obstructive sleep apnea (OSA) is a chronic disease treated effectively with the use of continuous positive airway pressure (CPAP) therapy. Patient adherence to prescribed CPAP is variable, however, leaving the undertreated OSA patient at risk of development or worsening of comorbid medical conditions, including hypertension and cardiovascular disease. The severity of disease and the presence of daytime sleepiness appear to have some predictive quality for subsequent adherence, though a search for consistent predictive factors related to CPAP adherence has proven elusive. Other influences, such as sex, age, socioeconomic status, and personality traits are less robust predictors. The use of sophisticated therapy modalities such as auto-titration or bi-level PAP units has been shown to improve adherence in certain subsets of OSA patients. Adverse effects such as nasal congestion, dry mouth, or skin irritation occur in approximately 50% of CPAP users, and addressing these adverse effects may improve adherence in some patients. More encouraging, studies on the use of intensive patient education and behavioral interventions have shown more positive effects on adherence, leading to the conclusion that improvement in patient adherence to CPAP therapy requires a multi-layered approach, using combined technological, behavioral, and adverse-effect interventions.
Ginzler, Ellen M; Wallace, Daniel J; Merrill, Joan T; Furie, Richard A; Stohl, William; Chatham, W Winn; Weinstein, Arthur; McKay, James D; McCune, W Joseph; Zhong, Z John; Freimuth, William W; Petri, Michelle A
2014-02-01
To evaluate the efficacy/safety of belimumab plus standard therapy in patients (n = 449) with active systemic lupus erythematosus (SLE) treated up to 7 years (n = 177 currently ongoing). Patients (n = 345) who completed a double-blind, placebo-controlled, 52-week study of belimumab 1, 4, or 10 mg/kg and 24-week extension of belimumab (placebo switched to 10 mg/kg; belimumab same dose or switched to 10 mg/kg) could receive belimumab 10 mg/kg in an open-label continuation study (n = 296). Disease activity was analyzed in patients with active SLE at baseline of the initial study. Biomarker and SLE medication changes were evaluated, and adverse events (AE) were monitored throughout the study. Total belimumab exposure over 7 years (double-blind and open-label periods): 1746 patient-years. SLE Responder Index (SRI) response rates at Week 52 in autoantibody-positive patients: placebo, 29%; belimumab, 46% (p < 0.05). In the continuation study, 57% of auto-antibody-positive patients had an SRI response by Year 2 and 65% by Year 7; severe flares occurred in 19% with placebo and 17% with belimumab during the first year, with the annual rate declining to 2%-9% during years 2-7. Anti-dsDNA autoantibodies in patients positive for them at baseline had a progressive decline of 40%-60% from baseline over 2-7 years with belimumab. Corticosteroid use decreased over time with ≥ 50-55% reduction in median dose during years 5-7. Serious and overall annual AE rates, including infections, were generally stable or decreased during 7-year treatment. Disease control and safety profile were maintained in patients with active SLE taking belimumab plus standard therapy for up to 7 years. [ClinicalTrials.gov numbers: NCT00071487 and NCT00583362].
Automotive Mechanics as Applied to Auto Body; Auto Body Repair and Refinishing 3: 9037.02.
ERIC Educational Resources Information Center
Dade County Public Schools, Miami, FL.
This is a course in which the student will receive the general information, technical knowledge, basic skills, attitudes, and values required for job entry level as an auto body repair helper. Course content includes general and specific goals, orientation, instruction in service tools and bench skills, and auto mechanics as applied to auto body.…
Health needs and concerns of male adolescents.
Pinch, W J; Heck, M; Vinal, D
1986-01-01
Lifestyle factors established within the family help determine health-care functioning. Adolescents first may be challenged to meet their own health needs as freshmen in college. A 153-item questionnaire was utilized to examine concerns in the areas of alcohol and other drug use, auto safety, weight and dieting, smoking, sexuality, coping and stress, and selection and utilization of health-care services. One hundred fifty-nine male college students responded. Major problems with alcohol use, auto safety, weight control, stress and sexuality were identified. Positive lifestyle factors that were strongly supported included regular exercise, nonsmoking, regular medical and dental checkups, and the development of some support systems to cope with stress. Health-care services designated by respondents to meet their own needs were significantly different from those services they pointed out as needed for their peers.
Development of the auto-steering software and equipment technology (ASSET)
NASA Astrophysics Data System (ADS)
McKay, Mark D.; Anderson, Matthew O.; Wadsworth, Derek C.
2003-09-01
The Idaho National Engineering and Environmental Laboratory (INEEL), through collaboration with INSAT Co., has developed a low cost robotic auto-steering system for parallel contour swathing. The capability to perform parallel contour swathing while minimizing "skip" and "overlap" is a necessity for cost-effective crop management within precision agriculture. Current methods for performing parallel contour swathing consist of using a Differential Global Position System (DGPS) coupled with a light bar system to prompt an operator where to steer. The complexity of operating heavy equipment, ensuring proper chemical mixture and application, and steering to a light bar indicator can be overwhelming to an operator. To simplify these tasks, an inexpensive robotic steering system has been developed and tested on several farming implements. This development leveraged research conducted by the INEEL and Utah State University. The INEEL-INSAT Auto-Steering Software and Equipment Technology provides the following: 1) the ability to drive in a straight line within +/- 2 feet while traveling at least 15 mph, 2) interfaces to a Real Time Kinematic (RTK) DGPS and sub-meter DGPS, 3) safety features such as Emergency-stop, steering wheel deactivation, computer watchdog deactivation, etc., and 4) a low-cost, field-ready system that is easily adapted to other systems.
Prototype of an auto-calibrating, context-aware, hybrid brain-computer interface.
Faller, J; Torrellas, S; Miralles, F; Holzner, C; Kapeller, C; Guger, C; Bund, J; Müller-Putz, G R; Scherer, R
2012-01-01
We present the prototype of a context-aware framework that allows users to control smart home devices and to access internet services via a Hybrid BCI system of an auto-calibrating sensorimotor rhythm (SMR) based BCI and another assistive device (Integra Mouse mouth joystick). While there is extensive literature that describes the merit of Hybrid BCIs, auto-calibrating and co-adaptive ERD BCI training paradigms, specialized BCI user interfaces, context-awareness and smart home control, there is up to now, no system that includes all these concepts in one integrated easy-to-use framework that can truly benefit individuals with severe functional disabilities by increasing independence and social inclusion. Here we integrate all these technologies in a prototype framework that does not require expert knowledge or excess time for calibration. In a first pilot-study, 3 healthy volunteers successfully operated the system using input signals from an ERD BCI and an Integra Mouse and reached average positive predictive values (PPV) of 72 and 98% respectively. Based on what we learned here we are planning to improve the system for a test with a larger number of healthy volunteers so we can soon bring the system to benefit individuals with severe functional disability.
Assessing Plankton and Particles with an Autonomous Imaging LOPC
2007-09-30
been modified to operate autonomously by auto-starting its programs on power-up and storing its data to an onboard flashcard . Since data transfer to... flashcard is a slow process, storage will occur when the AUV surfaces for a position fix. Data acquisition will commence as the AUV descends >5m
Remote gaze tracking system on a large display.
Lee, Hyeon Chang; Lee, Won Oh; Cho, Chul Woo; Gwon, Su Yeong; Park, Kang Ryoung; Lee, Heekyung; Cha, Jihun
2013-10-07
We propose a new remote gaze tracking system as an intelligent TV interface. Our research is novel in the following three ways: first, because a user can sit at various positions in front of a large display, the capture volume of the gaze tracking system should be greater, so the proposed system includes two cameras which can be moved simultaneously by panning and tilting mechanisms, a wide view camera (WVC) for detecting eye position and an auto-focusing narrow view camera (NVC) for capturing enlarged eye images. Second, in order to remove the complicated calibration between the WVC and NVC and to enhance the capture speed of the NVC, these two cameras are combined in a parallel structure. Third, the auto-focusing of the NVC is achieved on the basis of both the user's facial width in the WVC image and a focus score calculated on the eye image of the NVC. Experimental results showed that the proposed system can be operated with a gaze tracking accuracy of ±0.737°~±0.775° and a speed of 5~10 frames/s.
Remote Gaze Tracking System on a Large Display
Lee, Hyeon Chang; Lee, Won Oh; Cho, Chul Woo; Gwon, Su Yeong; Park, Kang Ryoung; Lee, Heekyung; Cha, Jihun
2013-01-01
We propose a new remote gaze tracking system as an intelligent TV interface. Our research is novel in the following three ways: first, because a user can sit at various positions in front of a large display, the capture volume of the gaze tracking system should be greater, so the proposed system includes two cameras which can be moved simultaneously by panning and tilting mechanisms, a wide view camera (WVC) for detecting eye position and an auto-focusing narrow view camera (NVC) for capturing enlarged eye images. Second, in order to remove the complicated calibration between the WVC and NVC and to enhance the capture speed of the NVC, these two cameras are combined in a parallel structure. Third, the auto-focusing of the NVC is achieved on the basis of both the user's facial width in the WVC image and a focus score calculated on the eye image of the NVC. Experimental results showed that the proposed system can be operated with a gaze tracking accuracy of ±0.737°∼±0.775° and a speed of 5∼10 frames/s. PMID:24105351
Edmands, William M B; Barupal, Dinesh K; Scalbert, Augustin
2015-03-01
MetMSLine represents a complete collection of functions in the R programming language as an accessible GUI for biomarker discovery in large-scale liquid-chromatography high-resolution mass spectral datasets from acquisition through to final metabolite identification forming a backend to output from any peak-picking software such as XCMS. MetMSLine automatically creates subdirectories, data tables and relevant figures at the following steps: (i) signal smoothing, normalization, filtration and noise transformation (PreProc.QC.LSC.R); (ii) PCA and automatic outlier removal (Auto.PCA.R); (iii) automatic regression, biomarker selection, hierarchical clustering and cluster ion/artefact identification (Auto.MV.Regress.R); (iv) Biomarker-MS/MS fragmentation spectra matching and fragment/neutral loss annotation (Auto.MS.MS.match.R) and (v) semi-targeted metabolite identification based on a list of theoretical masses obtained from public databases (DBAnnotate.R). All source code and suggested parameters are available in an un-encapsulated layout on http://wmbedmands.github.io/MetMSLine/. Readme files and a synthetic dataset of both X-variables (simulated LC-MS data), Y-variables (simulated continuous variables) and metabolite theoretical masses are also available on our GitHub repository. © The Author 2014. Published by Oxford University Press.
Edmands, William M. B.; Barupal, Dinesh K.; Scalbert, Augustin
2015-01-01
Summary: MetMSLine represents a complete collection of functions in the R programming language as an accessible GUI for biomarker discovery in large-scale liquid-chromatography high-resolution mass spectral datasets from acquisition through to final metabolite identification forming a backend to output from any peak-picking software such as XCMS. MetMSLine automatically creates subdirectories, data tables and relevant figures at the following steps: (i) signal smoothing, normalization, filtration and noise transformation (PreProc.QC.LSC.R); (ii) PCA and automatic outlier removal (Auto.PCA.R); (iii) automatic regression, biomarker selection, hierarchical clustering and cluster ion/artefact identification (Auto.MV.Regress.R); (iv) Biomarker—MS/MS fragmentation spectra matching and fragment/neutral loss annotation (Auto.MS.MS.match.R) and (v) semi-targeted metabolite identification based on a list of theoretical masses obtained from public databases (DBAnnotate.R). Availability and implementation: All source code and suggested parameters are available in an un-encapsulated layout on http://wmbedmands.github.io/MetMSLine/. Readme files and a synthetic dataset of both X-variables (simulated LC–MS data), Y-variables (simulated continuous variables) and metabolite theoretical masses are also available on our GitHub repository. Contact: ScalbertA@iarc.fr PMID:25348215
Real-time auto-adaptive margin generation for MLC-tracked radiotherapy
NASA Astrophysics Data System (ADS)
Glitzner, M.; Fast, M. F.; de Senneville, B. Denis; Nill, S.; Oelfke, U.; Lagendijk, J. J. W.; Raaymakers, B. W.; Crijns, S. P. M.
2017-01-01
In radiotherapy, abdominal and thoracic sites are candidates for performing motion tracking. With real-time control it is possible to adjust the multileaf collimator (MLC) position to the target position. However, positions are not perfectly matched and position errors arise from system delays and complicated response of the electromechanic MLC system. Although, it is possible to compensate parts of these errors by using predictors, residual errors remain and need to be compensated to retain target coverage. This work presents a method to statistically describe tracking errors and to automatically derive a patient-specific, per-segment margin to compensate the arising underdosage on-line, i.e. during plan delivery. The statistics of the geometric error between intended and actual machine position are derived using kernel density estimators. Subsequently a margin is calculated on-line according to a selected coverage parameter, which determines the amount of accepted underdosage. The margin is then applied onto the actual segment to accommodate the positioning errors in the enlarged segment. The proof-of-concept was tested in an on-line tracking experiment and showed the ability to recover underdosages for two test cases, increasing {{V}90 %} in the underdosed area about 47 % and 41 % , respectively. The used dose model was able to predict the loss of dose due to tracking errors and could be used to infer the necessary margins. The implementation had a running time of 23 ms which is compatible with real-time requirements of MLC tracking systems. The auto-adaptivity to machine and patient characteristics makes the technique a generic yet intuitive candidate to avoid underdosages due to MLC tracking errors.
Uzun, O; Topuz, O; Tinaz, C; Nekoofar, M H; Dummer, P M H
2008-09-01
To evaluate ex vivo the accuracy of the integrated electronic root canal length measurement devices within TCM Endo V and Tri Auto ZX motors whilst removing gutta-percha and sealer from filled root canals. Forty freshly extracted maxillary and mandibular incisor teeth with mature apices were selected. Following access cavity preparation, the length of the root canals were measured visually 0.5 mm short of the major foramen (TL). The canals were prepared using the HERO 642 system and then filled with gutta-percha and AH26 sealer using a lateral compaction technique. After 7 days the coronal temporary filling was removed and the roots mounted in an alginate experimental model. The roots were then randomly divided in two groups. The access cavities were filled with chloroform to soften the gutta-percha and allow its penetration using the Tri Auto ZX and the TCM Endo V devices in groups 1 and 2, respectively. The 'automatic apical reverse function' (ARL) of both devices was set to start at the 0.5 setting and the rotary instrument inserted inside the root canal until a beeping sound was heard and the rotation of the file stopped automatically. Once the auto reverse function had been initiated, the foot pedal of the motor was inactivated and the rubber stop placed against the reference point. The distance between the file tip and rubber stop was measured using a digital calliper to 0.01 mm accuracy (ARL). Then, a size 20, 0.02 taper instrument was attached to each device and inserted into the root canals without rotary motion until the integrated ERCLMDs positioned the instrument tips at the 0.5 setting as suggested by the devices. This length was again measured using a digital calliper (EL). The Mann-Whitney U-test was used to investigate statistical differences between the true canal length and those indicated by the two devices when used in 'automatic ARL and when inserted passively (EL). In the presence of gutta-percha, sealer and chloroform, the auto-reverse function for the Tri Auto ZX and TCM Endo V, set to start at 0.5 level, was initiated beyond the foramen in 60% and 95% of the samples, respectively during active (rotary) penetration of the instruments. There was a statistically significant difference between the devices for the mean discrepancies between the length at which the auto reverse function was initiated and the true length (P < 0.001). Electronic detection of the apical terminus when the instruments were introduced passively (not rotating) was beyond the foramen in 20% and 37% of cases in the Tri Auto ZX group and the TCM Endo V group, respectively. There was a statistically significant difference between the devices for the mean discrepancies between the electronically determined (passive) length and true length (P < 0.01). The auto reverse function of the Tri Auto ZX and TCM Endo V devices, set to start at 0.5 level, were initiated beyond the foramen in the majority of root-filled teeth during active (rotating) penetration of root filling material. Thus, this automatic function must be used with caution when removing gutta-percha root fillings. There were significant differences between the accuracy of measurements in active (rotating) and passive (not-rotating) modes; both devices were more accurate when used in passive mode. However, the Tri Auto ZX was significantly more accurate in a greater proportion of cases.
Repertoire of human natural anti-glycan immunoglobulins. Do we have auto-antibodies?
Bovin, Nicolai; Obukhova, Polina; Shilova, Nadezhda; Rapoport, Evgenia; Popova, Inna; Navakouski, Maksim; Unverzagt, Carlo; Vuskovic, Marko; Huflejt, Margaret
2012-09-01
Profiling of donor's antibodies using glycan arrays demonstrated presence of antibodies capable of binding to >100 mammalian glycans or their fragments. For example, relatively high binding to Galα1-4Galβ1-4GlcNAc (P(1)), Galα1-4Galβ1-4Glc (P(k)), Galβ1-3GlcNAc (Le(c)), 4-O-SuGalβ1-4GlcNAc, and GalNAcα1-3GalNAc (Fs) was found in all tested individuals. Affinity isolation using hapten-specific chromatography in combination with epitope mapping revealed their glycotopes. Notably, a significant part of the antibodies was capable of recognizing a fragment of larger glycans, for example, -Galβ1-4Glc of glycolipids, or Fucα1-3GlcNAc motif of Le(X)/Le(Y) antigens. Their epitope specificity did not vary between different healthy individuals. Nominally, all the mentioned immunoglobulins could be classified as auto-antibodies. In this work we re-evaluated results published earlier and analyzed new data to address the question why autologous antibodies found in healthy individuals do not cause severe auto-immune reactions. In all cases the presumably "auto" antibodies were found to bind short fragments "subtracted" from larger glycans whereas recognition of the same fragment in the context of the whole natural chain was completely abolished. Thus, in spite of numerous formally positive signals observed on the printed glycan array, we are yet unable to identify in blood serum of healthy individuals true auto-antibodies capable of binding carbohydrate chains in their naturally occurring form. The identified natural anti-glycan antibodies were found to be specific, high-titer and population conservative immunoglobulins - all of this suggesting as yet unknown biological role(s) of the studied proteins. This article is part of a Special Issue entitled Glycoproteomics. Copyright © 2012 Elsevier B.V. All rights reserved.
Schwebel, David C; Johnston, Anna; Shen, Jiabin; Li, Peng
2017-07-19
Transportation-related injuries are a leading cause of pediatric death, and effective interventions are limited. Otto the Auto is a website offering engaging, interactive activities. We evaluated Otto among a sample of sixty-nine 4- and 5-year-old children, who participated in a randomized parallel group design study. Following baseline evaluation, children engaged with either Otto or a control website for 2 weeks and then were re-evaluated. Children who used Otto failed to show increases in transportation safety knowledge or behavior compared to the control group, although there was a dosage effect whereby children who engaged in the website more with parents gained safer behavior patterns. We conclude Otto may have some efficacy when engaged by children with their parents, but continued efforts to develop and refine engaging, effective, theory-driven strategies to teach children transportation safety, including via internet, should be pursued.
Johnston, Anna; Shen, Jiabin; Li, Peng
2017-01-01
Transportation-related injuries are a leading cause of pediatric death, and effective interventions are limited. Otto the Auto is a website offering engaging, interactive activities. We evaluated Otto among a sample of sixty-nine 4- and 5-year-old children, who participated in a randomized parallel group design study. Following baseline evaluation, children engaged with either Otto or a control website for 2 weeks and then were re-evaluated. Children who used Otto failed to show increases in transportation safety knowledge or behavior compared to the control group, although there was a dosage effect whereby children who engaged in the website more with parents gained safer behavior patterns. We conclude Otto may have some efficacy when engaged by children with their parents, but continued efforts to develop and refine engaging, effective, theory-driven strategies to teach children transportation safety, including via internet, should be pursued. PMID:28753920
NASA Astrophysics Data System (ADS)
Wu, Hsin-Hung; Tsai, Ya-Ning
2012-11-01
This study uses both analytic hierarchy process (AHP) and decision-making trial and evaluation laboratory (DEMATEL) methods to evaluate the criteria in auto spare parts industry in Taiwan. Traditionally, AHP does not consider indirect effects for each criterion and assumes that criteria are independent without further addressing the interdependence between or among the criteria. Thus, the importance computed by AHP can be viewed as short-term improvement opportunity. On the contrary, DEMATEL method not only evaluates the importance of criteria but also depicts the causal relations of criteria. By observing the causal diagrams, the improvement based on cause-oriented criteria might improve the performance effectively and efficiently for the long-term perspective. As a result, the major advantage of integrating AHP and DEMATEL methods is that the decision maker can continuously improve suppliers' performance from both short-term and long-term viewpoints.
Wesseloo, Richard; Kamperman, Astrid M; Bergink, Veerle; Pop, Victor J M
2018-01-01
During the postpartum period, women are at risk for the new onset of both auto-immune thyroid disorders and depression. The presence of thyroid peroxidase antibodies (TPO-ab) during early gestation is predictive for postpartum auto-immune thyroid dysfunction. The aim of this study was to investigate the association between TPO-ab status during early gestation and first-onset postpartum depression. Prospective cohort study (n = 1075) with follow-up during pregnancy up to one year postpartum. Thyroid function and TPO-ab status were measured during early gestation. Depressive symptomatology was assessed during each trimester and at four time points postpartum with the Edinburgh Depression Scale (EDS). Women with antenatal depression were not eligible for inclusion. Self-reported postpartum depression was defined with an EDS cut-off of ≥ 13. The cumulative incidence of self-reported first-onset depression in the first postpartum year was 6.3%. A positive TPO-ab status was associated with an increased risk for self-reported first-onset depression at four months postpartum (adjusted OR 3.8; 95% CI 1.3-11.6), but not at other postpartum time points. Prevalence rates of self-reported postpartum depression declined after four months postpartum in the TPO-ab positive group, but remained constant in the TPO-ab negative group. Depression was defined with a self-rating questionnaire (EDS). Women with an increased TPO-ab titer during early gestation are at increased risk for self-reported first-onset depression. The longitudinal pattern of self-reported postpartum depression in the TPO-ab positive group was similar to the typical course of postpartum TPO-ab titers changes. This suggests overlap in the etiology of first-onset postpartum depression and auto-immune thyroid dysfunction. Thyroid function should be evaluated in women with first-onset postpartum depression. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhang, H.; Guo, H.; Lu, L.; Zahorchak, A. F.; Wiseman, R. W.; Raimondi, G.; Cooper, D. K. C.; Ezzelarab, M. B.; Thomson, A. W.
2016-01-01
Ex vivo-expanded cynomolgus monkey CD4+CD25+CD127− regulatory T cells (Treg) maintained Foxp3 demethylation status at the Treg-Specific Demethylation Region (TSDR), and potently suppressed T cell proliferation through 3 rounds of expansion. When CFSE- or VPD450-labeled autologous (auto) and non-autologous (non-auto) expanded Treg were infused into monkeys, the number of labeled auto-Treg in peripheral blood declined rapidly during the first week, but persisted at low levels in both normal and anti-thymocyte globulin plus rapamycin-treated (immunosuppressed; IS) animals for at least 3 weeks. By contrast, MHC-mismatched non-auto-Treg could not be detected in normal monkey blood or in blood of two out of the three IS monkeys by day 6 post-infusion. They were also more difficult to detect than auto-Treg in peripheral lymphoid tissue. Both auto- and non-auto-Treg maintained Ki67 expression early after infusion. Sequential monitoring revealed that adoptively-transferred auto-Treg maintained similarly high levels of Foxp3 and CD25 and low CD127 compared with endogenous Treg, although Foxp3 staining diminished over time in these non-transplanted recipients. Thus, infused ex vivo-expanded auto-Treg persist longer than MHC-mismatched non-auto-Treg in blood of non-human primates and can be detected in secondary lymphoid tissue. Host lymphodepletion and rapamycin administration did not consistently prolong the persistence of non-auto-Treg in these sites. PMID:25783759
DOE Office of Scientific and Technical Information (OSTI.GOV)
Courneyea, L; Mullins, J; Howard, M
2014-08-15
Purpose: Evaluate an immobilization system to determine its adequacy for the reduced margins required for proton therapy. Methods: Twelve head-and-neck cancer patients were immobilized for conventional photon radiotherapy and imaged with pre- and post-treatment cone beam CTs (CBCTs) for each treatment fraction. To quantify the patient positioning reproducibility, each CBCT was registered to the simulation CT offline. Registrations were performed using auto-match tools and a matching volume-of-interest (VOI) consisting of a 5mm expansion around the mandible, occipital bone, C1/C2 and C7/T1. For each registration, the bony anatomy in the VOI was evaluated for agreement with the simulation position using 3more » and 5mm margins. Registrations were initially restricted to translational corrections. If the bony anatomy did not agree with the simulation position to within 3mm or 5mm, the auto-match was repeated with 3 additional rotational corrections. Intrafraction motion was calculated as the difference between the pre- and post-treatment CBCT matches. Results: Pre-treatment patient positioning agreed with the simulation CT to within 3mm/5mm for 62%/86% of fractions using translational matching and 84%/100% of fractions when rotations were included. Intrafraction motion averaged 1.1±0.8mm, with 12% of fractions having >2mm intrafraction motion. Post-treatment positioning accuracy was 57%/84% and 80%/100% for registrations without/with rotations. For the mandible, positioning accuracy dropped from 93% pre-treatment to 82% post-treatment. Conclusion: If rotational corrections are available, the immobilization system studied created reproducible patient positioning to within 3mm for 84% of fractions. However, intrafraction motion caused additional anatomy to fall outside the 3mm margin by the end of treatment.« less
Surface treatment of dental porcelain: CO2 laser as an alternative to oven glaze.
Sgura, Ricardo; Reis, Mariana Cavalcante; Hernandes, Antonio Carlos; de Abreu Fantini, Márcia Carvalho; Andreeta, Marcello Rubens Barsi; Medeiros, Igor Studart
2015-02-01
This work tested continuous CO2 laser as a surface treatment to dental porcelain and compared it to oven glaze (auto-glaze) by means of roughness and color parameters. Three commercial veneering porcelains with different crystalline content were tested: VM7, VM9, and VM13. Porcelain discs (3.5 × 2.0 mm, diameter × height) were sintered and had one side ground by a diamond bur (45 μm) simulating a chairside adjustment in a clinical office. Specimens (n = 7) were divided into the following groups: C--control (no treatment), G--auto-glaze (oven), and L--surface continuous irradiation with CO2 laser (Gem Laser, Coherent; λ = 10.6 μm). Laser was tested in three exposure times (3, 4, or 5 min) and two irradiances (45 and 50 W/cm(2)). Roughness parameters (Ra, Rz, and Rpm/Rz) were measured using a rugosimeter (Surftest 301, Mitutoyo). Color differences (ΔE) between the G and L groups were calculated (VITA Easyshade); ΔE values up to 3.3 were considered as not perceivable. A surface analysis was conducted by stereomicroscopy (Olympus SZ61) and SEM (Stereoscan 440, LEO). Crystalline content of specimens from groups C and L (50 W/cm(2), 5 min) was assessed by X-ray diffraction and then compared. Surface roughness (Ra and Rz) observed for laser-irradiated groups was similar to G for all studied porcelains. Rpm/Rz ratios were near 1.0 for all groups that indicated a sharp ridge profile for all specimens. Only one laser condition studied (50 W/cm(2), 3 min) from VM7 porcelain resulted in color difference (ΔE = 3.5) to G. Specimens irradiated with 50 W/cm(2) for 5 min presented the smoother surface observed by SEM, comparable to G. X-ray diffraction data revealed an increase in leucite crystallite size for VM9 and VM13 porcelains after laser treatment. Regarding roughness, continuous CO2 laser applied on porcelain surface was as effective as conventional oven auto-glaze.
Evaluation on the impact of IMU grades on BDS + GPS PPP/INS tightly coupled integration
NASA Astrophysics Data System (ADS)
Gao, Zhouzheng; Ge, Maorong; Shen, Wenbin; Li, You; Chen, Qijin; Zhang, Hongping; Niu, Xiaoji
2017-09-01
The unexpected observing environments in dynamic applications may lead to partial and/or complete satellite signal outages frequently, which can definitely impact on the positioning performance of the Precise Point Positioning (PPP) in terms of decreasing available satellite numbers, breaking the continuity of observations, and degrading PPP's positioning accuracy. Generally, both the Inertial Navigation System (INS) and the multi-constellation Global Navigation Satellite System (GNSS) can be used to enhance the performance of PPP. This paper introduces the mathematical models of the multi-GNSS PPP/INS Tightly Coupled Integration (TCI), and investigates its performance from several aspects. Specifically, it covers (1) the use of the BDS/GPS PPP, PPP/INS, and their combination; (2) three positioning modes including PPP, PPP/INS TCI, and PPP/INS Loosely Coupled Integration (LCI); (3) the use of four various INS systems named navigation grade, tactical grade, auto grade, and Micro-Electro-Mechanical-Sensors (MEMS) one; (4) three PPP observation scenarios including PPP available, partially available, and fully outage. According to the statistics results, (1) the positioning performance of the PPP/INS (either TCI or LCI) mode is insignificantly depended on the grade of inertial sensor, when there are enough available satellites; (2) after the complete GNSS outages, the TCI mode expresses both higher convergence speed and more accurate positioning solutions than the LCI mode. Furthermore, in the TCI mode, using a higher grade inertial sensor is beneficial for the PPP convergence; (3) under the partial GNSS outage situations, the PPP/INS TCI mode position divergence speed is also restrained significantly; and (4) the attitude determination accuracy of the PPP/INS integration is highly correlated with the grade of inertial sensor.
Methods on observation of fluorescence micro-imaging for microalgae
NASA Astrophysics Data System (ADS)
Ou, Lin; Zhuang, Hui-ru; Chen, Rong; Lei, Jin-pin; Liao, Xiao-hua; Lin, Wen-suo
2007-11-01
Objective: Auto-fluorescence micro-imaging of microalgae are observed by using of laser scanning confocal microscopy (LSCM) and fluorescence microscopy, so as to investigate the effect of auto fluorescence alteration on growth of irradiated microalgae irradiated, meanwhile, the method of microalgae cells stained also to be studied. Methods: Platymonas subcordiformis, Phaeodactylum tricormutum and Isochyrsis zhanjiangensis cells are stained with acridine orange, and observed by fluorescence microscopy; the three types microalgae mentioned above are irradiated by Nd:YAP laser with 10w at 1341nm, irradiating time:12s, 30s, 35s and 55s, than to be cultured 6 days, and the auto fluorescence images and fluorescence spectra of algae cells are obtained by LSCM on lambda scan mode, at excitation 488nm (Ar + laser). Results: It is showed that the shapes and the structural features of microalgae cells stained can be seen clearly, and the cytoplasm and nucleus also can be observed. The chloroplasts in cell is bigger on promoting effects, conversely, it is to be mutilated, deformation and shrink. Contrast to the CK, the peak positions of fluorescence of algae cells irradiated is similar to the whole while the peak light intensity alters. On irradiation of promoting dose, however, the auto fluorescence intensity is enhanced more than control. Conclusions: The method of cell stained can be used to observed genetic material in microalgae. There are obvious effects for laser irradiating to chloroplasts in cells, the bigger chloroplasts the greater fluorescence intensity. Physiological incentive effects of microalgae irradiated can be given expression on fluorescence characteristics and fluorescence intensity alteration of cells.
Economic evaluation of epinephrine auto-injectors for peanut allergy.
Shaker, Marcus; Bean, Katherine; Verdi, Marylee
2017-08-01
Three commercial epinephrine auto-injectors were available in the United States in the summer of 2016: EpiPen, Adrenaclick, and epinephrine injection, USP auto-injector. To describe the variation in pharmacy costs among epinephrine auto-injector devices in New England and evaluate the additional expense associated with incremental auto-injector costs. Decision analysis software was used to evaluate costs of the most and least expensive epinephrine auto-injector devices for children with peanut allergy. To evaluate regional variation in epinephrine auto-injector costs, a random sample of New England national and corporate pharmacies was compared with a convenience sample of pharmacies from 10 Canadian provinces. Assuming prescriptions written for 2 double epinephrine packs each year (home and school), the mean costs of food allergy over the 20-year model horizon totaled $58,667 (95% confidence interval [CI] $57,745-$59,588) when EpiPen was prescribed and $45,588 (95% CI $44,873-$46,304) when epinephrine injection, USP auto-injector was prescribed. No effectiveness differences were evident between groups, with 17.19 (95% CI 17.11-17.27) quality-adjusted life years accruing for each subject. The incremental cost per episode of anaphylaxis treated with epinephrine over the model horizon was $12,576 for EpiPen vs epinephrine injection, USP auto-injector. EpiPen costs were lowest at Canadian pharmacies ($96, 95% CI $85-$107). There was price consistency between corporate and independent pharmacies throughout New England by device brand, with the epinephrine injection, USP auto-injector being the most affordable device. Cost differences among epinephrine auto-injectors were significant. More expensive auto-injector brands did not appear to provide incremental benefit. Copyright © 2017 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Unintentional Epinephrine Auto-injector Injuries: A National Poison Center Observational Study.
Anshien, Marco; Rose, S Rutherfoord; Wills, Brandon K
2016-11-24
Epinephrine is the only first-line therapeutic agent used to treat life-threatening anaphylaxis. Epinephrine auto-injectors are commonly carried by patients at risk for anaphylaxis, and reported cases of unintentional auto-injector injury have increased over the last decade. Modifications of existing designs and release of a new style of auto-injector are intended to reduce epinephrine auto-injector misuse. The aim of the study was to characterize reported cases of unintentional epinephrine auto-injector exposures from 2013 to 2014 and compare demographics, auto-injector model, and anatomical site of such exposures. The American Association of Poison Control Center's National Poison Data System was searched from January 1, 2013, to December 31, 2014, for cases of unintentional epinephrine auto-injector exposures. Anatomical site data were obtained from all cases reported to the Virginia Poison Center and participating regional poison center for Auvi-Q cases. A total of 6806 cases of unintentional epinephrine auto-injector exposures were reported to US Poison Centers in 2013 and 2014. Of these cases, 3933 occurred with EpiPen, 2829 with EpiPen Jr, 44 with Auvi-Q, and no case reported of Adrenaclick. The most common site of unintentional injection for traditional epinephrine auto-injectors was the digit or thumb, with 58% of cases for EpiPen and 39% of cases with EpiPen Jr. With Auvi-Q, the most common site was the leg (78% of cases). The number of unintentional epinephrine auto-injector cases reported to American Poison Centers in 2013-2014 has increased compared with previous data. Most EpiPen exposures were in the digits, whereas Auvi-Q was most frequently in the leg. Because of the limitations of Poison Center data, more research is needed to identify incidence of unintentional exposures and the effectiveness of epinephrine auto-injector redesign.
Research on remote sensing image pixel attribute data acquisition method in AutoCAD
NASA Astrophysics Data System (ADS)
Liu, Xiaoyang; Sun, Guangtong; Liu, Jun; Liu, Hui
2013-07-01
The remote sensing image has been widely used in AutoCAD, but AutoCAD lack of the function of remote sensing image processing. In the paper, ObjectARX was used for the secondary development tool, combined with the Image Engine SDK to realize remote sensing image pixel attribute data acquisition in AutoCAD, which provides critical technical support for AutoCAD environment remote sensing image processing algorithms.
Monogenic Auto-inflammatory Syndromes: A Review of the Literature.
Azizi, Gholamreza; Khadem Azarian, Shahin; Nazeri, Sepideh; Mosayebian, Ali; Ghiasy, Saleh; Sadri, Ghazal; Mohebi, Ali; Khan Nazer, Nikoo Hossein; Afraei, Sanaz; Mirshafiey, Abbas
2016-12-01
Auto-inflammatory syndromes are a new group of distinct hereditable disorders characterized by episodes of seemingly unprovoked inflammation (most commonly in skin, joints, gut, and eye), the absence of a high titer of auto-antibodies or auto-reactive T cells, and an inborn error of innate immunity. A narrative literature review was carried out of studies related to auto-inflammatory syndromes to discuss the pathogenesis and clinical manifestation of these syndromes. This review showed that the main monogenic auto-inflammatory syndromes are familial Mediterranean fever (FMF), mevalonate kinase deficiency (MKD), Blau syndrome, TNF receptor-associated periodic syndrome (TRAPS), cryopyrin-associated periodic syndrome (CAPS), and pyogenic arthritis with pyoderma gangrenosum and acne (PAPA). The data suggest that correct diagnosis and treatment of monogenic auto-inflammatory diseases relies on the physicians' awareness. Therefore, understanding of the underlying pathogenic mechanisms of auto-inflammatory syndromes, and especially the fact that these disorders are mediated by IL-1 secretion stimulated by monocytes and macrophages, facilitated significant progress in patient management.
Feedback circuit design of an auto-gating power supply for low-light-level image intensifier
NASA Astrophysics Data System (ADS)
Yang, Ye; Yan, Bo; Zhi, Qiang; Ni, Xiao-bing; Li, Jun-guo; Wang, Yu; Yao, Ze
2015-11-01
This paper introduces the basic principle of auto-gating power supply which using a hybrid automatic brightness control scheme. By the analysis of current as image intensifier to special requirements of auto-gating power supply, a feedback circuit of the auto-gating power supply is analyzed. Find out the reason of the screen flash after the auto-gating power supply assembled image intensifier. This paper designed a feedback circuit which can shorten the response time of auto-gating power supply and improve screen slight flicker phenomenon which the human eye can distinguish under the high intensity of illumination.
Enhancing Price Response Programs through Auto-DR: California's 2007 Implementation Experience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiliccote, Sila; Wikler, Greg; Chiu, Albert
2007-12-18
This paper describes automated demand response (Auto-DR) activities, an innovative effort in California to ensure that DR programs produce effective and sustainable impacts. Through the application of automation and communication technologies coupled with well-designed incentives and DR programs such as Critical Peak Pricing (CPP) and Demand Bidding (DBP), Auto-DR is opening up the opportunity for many different types of buildings to effectively participate in DR programs. We present the results of Auto-DR implementation efforts by the three California investor-owned utilities for the Summer of 2007. The presentation emphasizes Pacific Gas and Electric Company's (PG&E) Auto-DR efforts, which represents the largestmore » in the state. PG&E's goal was to recruit, install, test and operate 15 megawatts of Auto-DR system capability. We describe the unique delivery approaches, including optimizing the utility incentive structures designed to foster an Auto-DR service provider community. We also show how PG&E's Critical Peak Pricing (CPP) and Demand Bidding (DBP) options were called and executed under the automation platform. Finally, we show the results of the Auto-DR systems installed and operational during 2007, which surpassed PG&E's Auto-DR goals. Auto-DR is being implemented by a multi-disciplinary team including the California Investor Owned Utilities (IOUs), energy consultants, energy management control system vendors, the Lawrence Berkeley National Laboratory (LBNL), and the California Energy Commission (CEC).« less
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-30
... benefit of important fish and wildlife resources. The Refuge is a premiere bird watching destination with... of 1956 (16 U.S.C. 742(a)(4), as amended); and ``for the benefit of the United States Fish and... miles of hike/bike positions (Outdoor facility expansions trails; one auto tour Recreation Planner and...
Transport Traffic Analysis for Abusive Infrastructure Characterization
2012-09-01
3 month sample of spam directed toward the Hotmail web-mail service. Their false positive rate was between 0.0011 and 0.0014 [11]. Unlike autoRE, our...they used 240 machines to analyze a 220 GB Hotmail log in 1.5 hours. In another experiment on 2 months of Hotmail logs (450 GB), BotGraph was able to
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schetrit, Oren; Kim, Joyce; Yin, Rongxin
2014-08-01
Automated demand response (Auto-DR) is expected to close the loop between buildings and the grid by providing machine-to-machine communications to curtail loads without the need for human intervention. Hence, it can offer more reliable and repeatable demand response results to the grid than the manual approach and make demand response participation a hassle-free experience for customers. However, many building operators misunderstand Auto-DR and are afraid of losing control over their building operation. To ease the transition from manual to Auto-DR, we designed and implemented granular control of Auto-DR systems so that building operators could modify or opt out of individualmore » load-shed strategies whenever they wanted. This paper reports the research findings from this effort demonstrated through a field study in large commercial buildings located in New York City. We focused on (1) understanding how providing granular control affects building operators’ perspective on Auto-DR, and (2) evaluating the usefulness of granular control by examining their interaction with the Auto-DR user interface during test events. Through trend log analysis, interviews, and surveys, we found that: (1) the opt-out capability during Auto-DR events can remove the feeling of being forced into load curtailments and increase their willingness to adopt Auto-DR; (2) being able to modify individual load-shed strategies allows flexible Auto-DR participation that meets the building’s changing operational requirements; (3) a clear display of automation strategies helps building operators easily identify how Auto-DR is functioning and can build trust in Auto-DR systems.« less
Administration of the adrenaline auto-injector at the nursery/kindergarten/school in Western Japan.
Korematsu, Seigo; Fujitaka, Michiko; Ogata, Mika; Zaitsu, Masafumi; Motomura, Chikako; Kuzume, Kazuyo; Toku, Yuchiro; Ikeda, Masanori; Odajima, Hiroshi
2017-01-01
In view of the increasing prevalence of food allergies, there has been an associated increase in frequency of situations requiring an emergency response for anaphylaxis at the home, childcare facilities and educational institutions. To clarify the situation of adrenaline auto-injector administration in nursery/kindergarten/school, we carried out a questionnaire survey on pediatric physicians in Western Japan. In 2015, self-reported questionnaires were mailed to 421 physicians who are members of the West Japan Research Society Pediatric Clinical Allergy and Shikoku Research Society Pediatric Clinical Allergy. The response rate was 44% (185 physicians) where 160 physicians had a prescription registration for the adrenaline auto-injector. In the past year, 1,330 patients were prescribed the adrenaline auto-injector where 83 patients (6% of the prescribed patients) actually administered the adrenaline auto-injector, of which 14 patients (17% of the administered patients) self-administered the adrenaline auto-injector. "Guardians" at the nursery/kindergarten and elementary school were found to have administered the adrenaline auto-injector the most. Among 117 adrenaline auto-injector prescription-registered physicians, 79% had experienced nonadministration of adrenaline auto-injector at nursery/kindergarten/school when anaphylaxis has occurred. The most frequent reason cited for not administering the adrenaline auto-injector was "hesitation about the timing of administration." If the adrenaline auto-injector was administered after the guardian arrived at the nursery/kindergarten/school, it may lead to delayed treatment of anaphylaxis in which symptoms develop in minutes. Education and cooperation among physicians and nursery/kindergarten/school staff will reduce the number of children suffering unfortunate outcomes due to anaphylaxis.
V-TECS Guide for Auto Body Repair.
ERIC Educational Resources Information Center
Gregory, Margaret R.; Benson, Robert T.
This curriculum guide consists of materials for teaching a course in auto body repair. Addressed in the individual units of the guide are the following topics: the nature and scope of auto body repair; safety; tools; auto body construction; simple metal straightening; welding; painting and refinishing; refinishing complete lacquer; refinishing…
Conversations with AutoTutor Help Students Learn
ERIC Educational Resources Information Center
Graesser, Arthur C.
2016-01-01
AutoTutor helps students learn by holding a conversation in natural language. AutoTutor is adaptive to the learners' actions, verbal contributions, and in some systems their emotions. Many of AutoTutor's conversation patterns simulate human tutoring, but other patterns implement ideal pedagogies that open the door to computer tutors eclipsing…
Forcina, Alessandra; Lorentino, Francesca; Marasco, Vincenzo; Oltolini, Chiara; Marcatti, Magda; Greco, Raffaella; Lupo-Stanghellini, Maria Teresa; Carrabba, Matteo; Bernardi, Massimo; Peccatori, Jacopo; Corti, Consuelo; Ciceri, Fabio
2018-03-02
Multidrug-resistant Gram-negative bacteria (MDR-GNB) are an emerging cause of morbidity and mortality after hematopoietic stem cell transplantation (HSCT). Three-hundred forty-eight consecutive patients transplanted at our hospital from July 2012 to January 2016 were screened for a pretransplant MDR-GNB colonization and evaluated for clinical outcomes. A pretransplant MDR-GNB colonization was found in 16.9% of allo-HSCT and in 9.6% of auto-HSCT recipients. Both in auto- and in allo-HSCT, carriers of a MDR-GNB showed no significant differences in overall survival (OS), transplant-related mortality (TRM), or infection-related mortality (IRM) compared with noncarriers. OS at 2 years for carriers compared with noncarriers was 85% versus 81% (P = .262) in auto-HSCT and 50% versus 43% (P = .091) in allo-HSCT. TRM at 2 years was 14% versus 5% (P = .405) in auto-HSCT and 31% versus 25% (P = .301) in allo-HSCT. IRM at 2 years was 14% versus 2% (P = .142) in auto-HSCT and 23% versus 14% (P = .304) in allo-HSCT. In multivariate analysis, only grade III to IV acute graft-versus-host disease was an independent factor for reduced OS (P < .001) and increased TRM (P < .001) and IRM (P < .001). During the first year after transplant, we collected 73 GNB bloodstream infectious (BSI) episodes in 54 patients, 42.4% of which sustained by a MDR-GNB. Rectal swabs positivity associated with the pathogen causing subsequent MDR-GNB BSI episodes in 13 of 31 (41.9%). Overall, OS at 4 months from MDR-GNB BSI episode onset was of 67.9%, with a 14-day attributed mortality of 12.9%, not being significantly different between carriers and noncarriers (P = .207). We conclude that in this extended single-center experience, a pretransplant MDR-GNB colonization did not significantly influence OS, TRM, and IRM both in auto- and allo-HSCT settings and that MDR-GNB attributed mortality can be controlled in carriers when an early pre-emptive antimicrobial therapy is started in case of neutropenic fever. Copyright © 2018 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
Construction and development of an auto-regulatory gene expression system in Bacillus subtilis.
Guan, Chengran; Cui, Wenjing; Cheng, Jintao; Zhou, Li; Guo, Junling; Hu, Xu; Xiao, Guoping; Zhou, Zhemin
2015-09-21
Bacillus subtilis is an all-important Gram-positive bacterium of valuable biotechnological utility that has been widely used to over-produce industrially and pharmaceutically relevant proteins. There are a variety of expression systems in terms of types of transcriptional patterns, among which the auto-inducible and growth-phase-dependent promoters are gaining increasing favor due to their inducer-independent feature, allowing for the potential to industrially scale-up. To expand the applicability of the auto-inducible expression system, a novel auto-regulatory expression system coupled with cell density was constructed and developed in B. subtilis using the quorum-sensing related promoter srfA (PsrfA). The promoter of the srf operon was used to construct an expression plasmid with the green fluorescent protein (GFP) downstream of PsrfA. The expression displayed a cell-density-dependent pattern in that GFP had a fairly low expression level at the early exponential stage and was highly expressed at the late exponential as well as the stationary stages. Moreover, the recombinant system had a similar expression pattern in wild-type B. subtilis 168, WB600, and WB800, as well as in B. subtilis 168 derivative strain 1681, with the complete deletion of PsrfA, indicating the excellent compatibility of this system. Noticeably, the expression strength of PsrfA was enhanced by optimizing the -10 and -35 core sequence by substituting both sequences with consensus sequences. Importantly, the expression pattern was successfully developed in an auto-regulatory cell-density coupling system by the simple addition of glucose in which GFP could not be strongly expressed until glucose was depleted, resulting in a greater amount of the GFP product and increased cell density. The expression system was eventually tested by the successful over-production of aminopeptidase to a desired level. The auto-regulatory cell density coupling system that is mediated by PsrfA is a novel expression system that has an expression pattern that is split between cell-growth and over-expression, leading to an increase in cell density and elevating the overall expression levels of heterologously expressed proteins. The broad applicability of this system and inducer-free expression property in B. subtilis facilitate the industrial scale-up and medical applications for the over-production of a variety of desired proteins.
SU-E-T-195: Gantry Angle Dependency of MLC Leaf Position Error
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ju, S; Hong, C; Kim, M
Purpose: The aim of this study was to investigate the gantry angle dependency of the multileaf collimator (MLC) leaf position error. Methods: An automatic MLC quality assurance system (AutoMLCQA) was developed to evaluate the gantry angle dependency of the MLC leaf position error using an electronic portal imaging device (EPID). To eliminate the EPID position error due to gantry rotation, we designed a reference maker (RM) that could be inserted into the wedge mount. After setting up the EPID, a reference image was taken of the RM using an open field. Next, an EPID-based picket-fence test (PFT) was performed withoutmore » the RM. These procedures were repeated at every 45° intervals of the gantry angle. A total of eight reference images and PFT image sets were analyzed using in-house software. The average MLC leaf position error was calculated at five pickets (-10, -5, 0, 5, and 10 cm) in accordance with general PFT guidelines using in-house software. This test was carried out for four linear accelerators. Results: The average MLC leaf position errors were within the set criterion of <1 mm (actual errors ranged from -0.7 to 0.8 mm) for all gantry angles, but significant gantry angle dependency was observed in all machines. The error was smaller at a gantry angle of 0° but increased toward the positive direction with gantry angle increments in the clockwise direction. The error reached a maximum value at a gantry angle of 90° and then gradually decreased until 180°. In the counter-clockwise rotation of the gantry, the same pattern of error was observed but the error increased in the negative direction. Conclusion: The AutoMLCQA system was useful to evaluate the MLC leaf position error for various gantry angles without the EPID position error. The Gantry angle dependency should be considered during MLC leaf position error analysis.« less
Spiro, J R; White, S; Quinn, N; Gubran, C J; Ludman, P F; Townend, J N; Doshi, S N
2015-02-01
Poor quality cardiopulmonary resuscitation (CPR) predicts adverse outcome. During invasive cardiac procedures automated-CPR (A-CPR) may help maintain effective resuscitation. The use of A-CPR following in-hospital cardiac arrest (IHCA) remains poorly described. Firstly, we aimed to assess the efficiency of healthcare staff using A-CPR in a cardiac arrest scenario at baseline, following re-training and over time (Scenario-based training). Secondly, we studied our clinical experience of A-CPR at our institution over a 2-year period, with particular emphasis on the details of invasive cardiac procedures performed, problems encountered, resuscitation rates and in-hospital outcome (AutoPulse-CPR Registry). Scenario-based training: Forty healthcare professionals were assessed. At baseline, time-to-position device was slow (mean 59 (±24) s (range 15-96s)), with the majority (57%) unable to mode-switch. Following re-training time-to-position reduced (28 (±9) s, p<0.01 vs baseline) with 95% able to mode-switch. This improvement was maintained over time. AutoPulse-CPR Registry: 285 patients suffered IHCA, 25 received A-CPR. Survival to hospital discharge following conventional CPR was 28/260 (11%) and 7/25 (28%) following A-CPR. A-CPR supported invasive procedures in 9 patients, 2 of whom had A-CPR dependant circulation during transfer to the catheter lab. A-CPR may provide excellent haemodynamic support and facilitate simultaneous invasive cardiac procedures. A significant learning curve exists when integrating A-CPR into clinical practice. Further studies are required to better define the role and effectiveness of A-CPR following IHCA. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Type of mask may impact on continuous positive airway pressure adherence in apneic patients.
Borel, Jean Christian; Tamisier, Renaud; Dias-Domingos, Sonia; Sapene, Marc; Martin, Francis; Stach, Bruno; Grillet, Yves; Muir, Jean François; Levy, Patrick; Series, Frederic; Pepin, Jean-Louis
2013-01-01
In obstructive sleep apnea patients (OSA), continuous positive airway pressure (CPAP) adherence is crucial to improve symptoms and cardiometabolic outcomes. The choice of mask may influence CPAP adherence but this issue has never been addressed properly. To evaluate the impact of nasal pillows, nasal and oronasal masks on CPAP adherence in a cohort of OSA. Newly CPAP treated OSA participating in "Observatoire Sommeil de la Fédération de Pneumologie", a French national prospective cohort, were included between March 2009 and December 2011. Anthropometric data, medical history, OSA severity, sleepiness, depressive status, treatment modalities (auto-CPAP versus fixed pressure, pressure level, interface type, use of humidifiers) and CPAP-related side effects were included in multivariate analysis to determine independent variables associated with CPAP adherence. 2311 OSA (age = 57(12) years, apnea+hypopnea index = 41(21)/h, 29% female) were included. Nasal masks, oronasal masks and nasal pillows were used by 62.4, 26.2 and 11.4% of the patients, respectively. In univariate analysis, oronasal masks and nasal pillows were associated with higher risk of CPAP non-adherence. CPAP non-adherence was also associated with younger age, female gender, mild OSA, gastroesophageal reflux, depression status, low effective pressure and CPAP-related side effects. In multivariate analysis, CPAP non-adherence was associated with the use of oronasal masks (OR = 2.0; 95%CI = 1.6; 2.5), depression, low effective pressure, and side effects. As oronasal masks negatively impact on CPAP adherence, a nasal mask should be preferred as the first option. Patients on oronasal masks should be carefully followed.
Automatic Scaling of Digisonde Ionograms Test and Evaluation Report.
1982-09-01
Labrador 30 21 IManual MUF - Auto MUFj/Manual MUF April 1980 Goose Bay, Labrador 31 22 IManual MUF - Auto MUFI /Manual MUF July 1980 Goose Bay...Labrador 32 23 IManual MUF - Auto MUFI /Manual MUF September 1980 Goose Bay, Labrador 33 24 !Manual M(3000) - Auto M(3000)1 January 1980 Goose Bay, Labrador
;height:auto;overflow:hidden}.poc_table .top_row{background-color:#eee;height:auto;overflow:hidden}.poc_table ;background-color:#FFF;height:auto;overflow:hidden;border-top:1px solid #ccc}.poc_table .main_row .name :200px;padding:5px;height:auto;overflow:hidden}.tli_grey_box{background-color:#eaeaea;text-align:center
Clinical utility of anti-p53 auto-antibody: systematic review and focus on colorectal cancer.
Suppiah, Aravind; Greenman, John
2013-08-07
Mutation of the p53 gene is a key event in the carcinogenesis of many different types of tumours. These can occur throughout the length of the p53 gene. Anti-p53 auto-antibodies are commonly produced in response to these p53 mutations. This review firstly describes the various mechanisms of p53 dysfunction and their association with subsequent carcinogenesis. Following this, the mechanisms of induction of anti-p53 auto-antibody production are shown, with various hypotheses for the discrepancies between the presence of p53 mutation and the presence/absence of anti-p53 auto-antibodies. A systematic review was performed with a descriptive summary of key findings of each anti-p53 auto-antibody study in all cancers published in the last 30 years. Using this, the cumulative frequency of anti-p53 auto-antibody in each cancer type is calculated and then compared with the incidence of p53 mutation in each cancer to provide the largest sample calculation and correlation between mutation and anti-p53 auto-antibody published to date. Finally, the review focuses on the data of anti-p53 auto-antibody in colorectal cancer studies, and discusses future strategies including the potentially promising role using anti-p53 auto-antibody presence in screening and surveillance.
Fline-Barthes, M-H; Vandendriessche, D; Gaugue, J; Urso, L; Therby, D; Subtil, D
2015-05-01
To evaluate auto-questionnaire use for psychosocial vulnerability and substance use (smoking, alcohol consumption, depression, intimate violence) screening during pregnancy versus usual medical report. An auto-questionnaire based on validated tests (Fagerström/HSI, T-ACE, EPDS, SSQ6) was proposed to 1977 pregnant patients at their first obstetrical consultation. We compared results of auto-questionnaire and usual medical questioning. The auto-questionnaire was filled by 1676 pregnant patients (89.4 %). The two Fagerström/HIS questions showed that 20.7 % smoked during pregnancy. T-ACE score was better than usual medical questioning to detect excessive alcohol consumption (4.0 % vs 0.1 %, P<0.05). Drug use before pregnancy was reported by 9.8 % patients in auto-questionnaire, but was only found in 4.9 % of medical files (P<0.001). Seven percent patients reported at least 3 depressive symptoms on 4 purposed in auto-questionnaire. Intimate violence, physical or psychological, was reported in 9.4 %. All of these vulnerability factors were linked together, in auto-questionnaire or in usual medical reports. Using auto-questionnaire based on standardized screening tests could help medical practioneers to detect psychosocial vulnerability and/or substance use during pregnancy. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Mori, Shinichiro; Shibayama, Kouichi; Tanimoto, Katsuyuki; Kumagai, Motoki; Matsuzaki, Yuka; Furukawa, Takuji; Inaniwa, Taku; Shirai, Toshiyuki; Noda, Koji; Tsuji, Hiroshi; Kamada, Tadashi
2012-09-01
Our institute has constructed a new treatment facility for carbon ion scanning beam therapy. The first clinical trials were successfully completed at the end of November 2011. To evaluate patient setup accuracy, positional errors between the reference Computed Tomography (CT) scan and final patient setup images were calculated using 2D-3D registration software. Eleven patients with tumors of the head and neck, prostate and pelvis receiving carbon ion scanning beam treatment participated. The patient setup process takes orthogonal X-ray flat panel detector (FPD) images and the therapists adjust the patient table position in six degrees of freedom to register the reference position by manual or auto- (or both) registration functions. We calculated residual positional errors with the 2D-3D auto-registration function using the final patient setup orthogonal FPD images and treatment planning CT data. Residual error averaged over all patients in each fraction decreased from the initial to the last treatment fraction [1.09 mm/0.76° (averaged in the 1st and 2nd fractions) to 0.77 mm/0.61° (averaged in the 15th and 16th fractions)]. 2D-3D registration calculation time was 8.0 s on average throughout the treatment course. Residual errors in translation and rotation averaged over all patients as a function of date decreased with the passage of time (1.6 mm/1.2° in May 2011 to 0.4 mm/0.2° in December 2011). This retrospective residual positional error analysis shows that the accuracy of patient setup during the first clinical trials of carbon ion beam scanning therapy was good and improved with increasing therapist experience.
Glavey, S V; Gertz, M A; Dispenzieri, A; Kumar, S; Buadi, F; Lacy, M; Hayman, S R; Kapoor, P; Dingli, D; McCurdy, A; Hogan, W J; Gastineau, D A; Leung, N
2013-11-01
Renal failure commonly complicates multiple myeloma (MM) and is associated with reduced survival. It is not clear whether auto-SCT results in improved renal function or attainment of independence from dialysis in patients with advanced renal impairment due to MM. We conducted a retrospective cohort study of all patients who underwent auto-SCT for MM complicated by advanced renal failure at our institution over a 10-year period (2000-2010). We aimed to assess the association between auto-SCT and renal outcome in patients with serum creatinine (SCr) over 3 mg/dL, attributable to MM, including those who were dialysis dependent. Thirty patients (2.8% of all auto-SCT patients) met inclusion criteria. Fourteen of 15 patients who were dialysis dependent before auto-SCT remained dialysis dependent in the long term despite hematological response (HR). Of the remaining 15 patients with SCr >3 mg/dL, an improvement in glomerular filtration rate (GFR) from 15 to 19.4 mL/min/1.73 m(2) was noted post auto-SCT (P=0.035); however, neither HR post auto-SCT or pre-existing renal function were independently associated with renal outcome. Auto-SCT was not associated with independence from dialysis in patients with renal failure due to MM at our institution. Although auto-SCT was associated with an improvement in GFR in patients with SCr >3 mg/dL, this improvement was not related to HR.
Kang, Ji-Man; Lee, Ji Won; Yoo, Keon Hee; Kim, Yae-Jean; Sung, Ki Woong; Koo, Hong Hoe
2016-01-01
We retrospectively analyzed infectious complications during tandem high-dose chemotherapy and autologous stem cell transplantation (HDCT/auto-SCT) in children and adolescents with high-risk or recurrent solid tumors. A total of 324 patients underwent their first HDCT/auto-SCT between October 2004 and September 2014, and 283 of them proceeded to their second HDCT/auto-SCT (a total of 607 HDCT/auto-SCTs). During the early transplant period of 607 HDCT/auto-SCTs (from the beginning of HDCT to day 30 post-transplant), bacteremia, urinary tract infection (UTI), respiratory virus infection, and varicella zoster virus (VZV) reactivation occurred in 7.1%, 2.3%, 13.0%, and 2.5% of HDCT/auto-SCTs, respectively. The early transplant period of the second HDCT/auto-SCT had infectious complications similar to the first HDCT/auto-SCT. During the late transplant period of HDCT/auto-SCT (from day 31 to 1 year post-transplant), bacteremia, UTI, and VZV reactivation occurred in 7.5%, 2.5%, and 3.9% of patients, respectively. Most infectious complications in the late transplant period occurred during the first 6 months post-transplant. There were no invasive fungal infections during the study period. Six patients died from infectious complications (4 from bacterial sepsis and 2 from respiratory virus infection). Our study suggests that infectious complications are similar following second and first HDCT/auto-SCT in children. PMID:27627440
Information Theory to Probe Intrapartum Fetal Heart Rate Dynamics
NASA Astrophysics Data System (ADS)
Granero-Belinchon, Carlos; Roux, Stéphane; Abry, Patrice; Doret, Muriel; Garnier, Nicolas
2017-11-01
Intrapartum fetal heart rate (FHR) monitoring constitutes a reference tool in clinical practice to assess the baby health status and to detect fetal acidosis. It is usually analyzed by visual inspection grounded on FIGO criteria. Characterization of Intrapartum fetal heart rate temporal dynamics remains a challenging task and continuously receives academic research efforts. Complexity measures, often implemented with tools referred to as \\emph{Approximate Entropy} (ApEn) or \\emph{Sample Entropy} (SampEn), have regularly been reported as significant features for intrapartum FHR analysis. We explore how Information Theory, and especially {\\em auto mutual information} (AMI), is connected to ApEn and SampEn and can be used to probe FHR dynamics. Applied to a large (1404 subjects) and documented database of FHR data, collected in a French academic hospital, it is shown that i) auto mutual information outperforms ApEn and SampEn for acidosis detection in the first stage of labor and continues to yield the best performance in the second stage; ii) Shannon entropy increases as labor progresses, and is always much larger in the second stage;iii) babies suffering from fetal acidosis additionally show more structured temporal dynamics than healthy ones and that this progressive structuration can be used for early acidosis detection.
Akhtar, Rizwan S; Licata, Joseph P; Luk, Kelvin C; Shaw, Leslie M; Trojanowski, John Q; Lee, Virginia M-Y
2018-03-03
Biomarkers for α-synuclein are needed for diagnosis and prognosis in Parkinson's disease (PD). Endogenous auto-antibodies to α-synuclein could serve as biomarkers for underlying synucleinopathy, but previous assessments of auto-antibodies have shown variability and inconsistent clinical correlations. We hypothesized that auto-antibodies to α-synuclein could be diagnostic for PD and explain its clinical heterogeneity. To test this hypothesis, we developed an enzyme-linked immunosorbent assay for measuring α-synuclein auto-antibodies in human samples. We evaluated 69 serum samples (16 healthy controls (HC) and 53 PD patients) and 145 CSF samples (52 HC and 93 PD patients) from our Institution. Both serum and CSF were available for 24 participants. Males had higher auto-antibody levels than females in both fluids. CSF auto-antibody levels were significantly higher in PD patients as compared to HC, whereas serum levels were not significantly different. CSF auto-antibody levels did not associate with amyloid-β 1-42 , total tau, or phosphorylated tau. CSF auto-antibody levels correlated with performance on the Montreal Cognitive Assessment, even when controlled for CSF amyloidβ 1-42 . CSF hemoglobin levels, as a proxy for contamination of CSF by blood during lumbar puncture, did not influence these observations. Using recombinant α-synuclein with N- and C-terminal truncations, we found that CSF auto-antibodies target amino acids 100 through 120 of α-synuclein. We conclude that endogenous CSF auto-antibodies are significantly higher in PD patients as compared to HC, suggesting that they could indicate the presence of underlying synucleinopathy. These auto-antibodies associate with poor cognition, independently of CSF amyloidβ 1-42 ., and target a select C-terminal region of α-synuclein. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Casulo, Carla; Friedberg, Jonathan W; Ahn, Kwang W; Flowers, Christopher; DiGilio, Alyssa; Smith, Sonali M; Ahmed, Sairah; Inwards, David; Aljurf, Mahmoud; Chen, Andy I; Choe, Hannah; Cohen, Jonathon; Copelan, Edward; Farooq, Umar; Fenske, Timothy S; Freytes, Cesar; Gaballa, Sameh; Ganguly, Siddhartha; Jethava, Yogesh; Kamble, Rammurti T; Kenkre, Vaishalee P; Lazarus, Hillard; Lazaryan, Aleksandr; Olsson, Richard F; Rezvani, Andrew R; Rizzieri, David; Seo, Sachiko; Shah, Gunjan L; Shah, Nina; Solh, Melham; Sureda, Anna; William, Basem; Cumpston, Aaron; Zelenetz, Andrew D; Link, Brian K; Hamadani, Mehdi
2018-06-01
Patients with follicular lymphoma (FL) experiencing early therapy failure (ETF) within 2 years of frontline chemoimmunotherapy have poor overall survival (OS). We analyzed data from the Center for International Blood and Marrow Transplant Research (CIBMTR) and the National LymphoCare Study (NLCS) to determine whether autologous hematopoietic cell transplant (autoHCT) can improve outcomes in this high-risk FL subgroup. ETF was defined as failure to achieve at least partial response after frontline chemoimmunotherapy or lymphoma progression within 2 years of frontline chemoimmunotherapy. We identified 2 groups: the non-autoHCT cohort (patients from the NLCS with ETF not undergoing autoHCT) and the autoHCT cohort (CIBMTR patients with ETF undergoing autoHCT). All patients received rituximab-based chemotherapy as frontline treatment; 174 non-autoHCT patients and 175 autoHCT patients were identified and analyzed. There was no difference in 5-year OS between the 2 groups (60% versus 67%, respectively; P = .16). A planned subgroup analysis showed that patients with ETF receiving autoHCT soon after treatment failure (≤1 year of ETF; n = 123) had higher 5-year OS than those without autoHCT (73% versus 60%, P = .05). On multivariate analysis, early use of autoHCT was associated with significantly reduced mortality (hazard ratio, .63; 95% confidence interval, .42 to .94; P = .02). Patients with FL experiencing ETF after frontline chemoimmunotherapy lack optimal therapy. We demonstrate improved OS when receiving autoHCT within 1 year of treatment failure. Results from this unique collaboration between the NLCS and CIBMTR support consideration of early consolidation with autoHCT in select FL patients experiencing ETF. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
Yu, J S; Chen, W J; Ni, M H; Chan, W H; Yang, S D
1998-08-15
Autophosphorylation-dependent protein kinase (auto-kinase) was identified from pig brain and liver on the basis of its unique autophosphorylation/activation property [Yang, Fong, Yu and Liu (1987) J. Biol. Chem. 262, 7034-7040; Yang, Chang and Soderling (1987) J. Biol. Chem. 262, 9421-9427]. Its substrate consensus sequence motif was determined as being -R-X-(X)-S*/T*-X3-S/T-. To characterize auto-kinase further, we partly sequenced the kinase purified from pig liver. The N-terminal sequence (VDGGAKTSDKQKKKAXMTDE) and two internal peptide sequences (EKLRTIV and LQNPEK/ILTP/FI) of auto-kinase were obtained. These sequences identify auto-kinase as a C-terminal catalytic fragment of p21-activated protein kinase 2 (PAK2 or gamma-PAK) lacking its N-terminal regulatory region. Auto-kinase can be recognized by an antibody raised against the C-terminal peptide of human PAK2 by immunoblotting. Furthermore the autophosphorylation site sequence of auto-kinase was successfully predicted on the basis of its substrate consensus sequence motif and the known PAK2 sequence, and was further demonstrated to be RST(P)MVGTPYWMAPEVVTR by phosphoamino acid analysis, manual Edman degradation and phosphopeptide mapping via the help of phosphorylation site analysis of a synthetic peptide corresponding to the sequence of PAK2 from residues 396 to 418. During the activation process, auto-kinase autophosphorylates mainly on a single threonine residue Thr402 (according to the sequence numbering of human PAK2). In addition, a phospho-specific antibody against a synthetic phosphopeptide containing this identified sequence was generated and shown to be able to differentially recognize the activated auto-kinase autophosphorylated at Thr402 but not the non-phosphorylated/inactive auto-kinase. Immunoblot analysis with this phospho-specific antibody further revealed that the change in phosphorylation level of Thr402 of auto-kinase was well correlated with the activity change of the kinase during both autophosphorylation/activation and protein phosphatase-mediated dephosphorylation/inactivation processes. Taken together, our results identify Thr402 as the regulatory autophosphorylation site of auto-kinase, which is a C-terminal catalytic fragment of PAK2.
Yu, J S; Chen, W J; Ni, M H; Chan, W H; Yang, S D
1998-01-01
Autophosphorylation-dependent protein kinase (auto-kinase) was identified from pig brain and liver on the basis of its unique autophosphorylation/activation property [Yang, Fong, Yu and Liu (1987) J. Biol. Chem. 262, 7034-7040; Yang, Chang and Soderling (1987) J. Biol. Chem. 262, 9421-9427]. Its substrate consensus sequence motif was determined as being -R-X-(X)-S*/T*-X3-S/T-. To characterize auto-kinase further, we partly sequenced the kinase purified from pig liver. The N-terminal sequence (VDGGAKTSDKQKKKAXMTDE) and two internal peptide sequences (EKLRTIV and LQNPEK/ILTP/FI) of auto-kinase were obtained. These sequences identify auto-kinase as a C-terminal catalytic fragment of p21-activated protein kinase 2 (PAK2 or gamma-PAK) lacking its N-terminal regulatory region. Auto-kinase can be recognized by an antibody raised against the C-terminal peptide of human PAK2 by immunoblotting. Furthermore the autophosphorylation site sequence of auto-kinase was successfully predicted on the basis of its substrate consensus sequence motif and the known PAK2 sequence, and was further demonstrated to be RST(P)MVGTPYWMAPEVVTR by phosphoamino acid analysis, manual Edman degradation and phosphopeptide mapping via the help of phosphorylation site analysis of a synthetic peptide corresponding to the sequence of PAK2 from residues 396 to 418. During the activation process, auto-kinase autophosphorylates mainly on a single threonine residue Thr402 (according to the sequence numbering of human PAK2). In addition, a phospho-specific antibody against a synthetic phosphopeptide containing this identified sequence was generated and shown to be able to differentially recognize the activated auto-kinase autophosphorylated at Thr402 but not the non-phosphorylated/inactive auto-kinase. Immunoblot analysis with this phospho-specific antibody further revealed that the change in phosphorylation level of Thr402 of auto-kinase was well correlated with the activity change of the kinase during both autophosphorylation/activation and protein phosphatase-mediated dephosphorylation/inactivation processes. Taken together, our results identify Thr402 as the regulatory autophosphorylation site of auto-kinase, which is a C-terminal catalytic fragment of PAK2. PMID:9693111
Farino, A.J.; Montague, S.; Sniegowski, J.J.; Smith, J.H.; McWhorter, P.J.
1998-07-21
A method is disclosed for photolithographically defining device features up to the resolution limit of an auto-focusing projection stepper when the device features are to be formed in a wafer cavity at a depth exceeding the depth of focus of the stepper. The method uses a focusing cavity located in a die field at the position of a focusing light beam from the auto-focusing projection stepper, with the focusing cavity being of the same depth as one or more adjacent cavities wherein a semiconductor device is to be formed. The focusing cavity provides a bottom surface for referencing the focusing light beam and focusing the stepper at a predetermined depth below the surface of the wafer, whereat the device features are to be defined. As material layers are deposited in each device cavity to build up a semiconductor structure such as a microelectromechanical system (MEMS) device, the same material layers are deposited in the focusing cavity, raising the bottom surface and re-focusing the stepper for accurately defining additional device features in each succeeding material layer. The method is especially applicable for forming MEMS devices within a cavity or trench and integrating the MEMS devices with electronic circuitry fabricated on the wafer surface. 15 figs.
Farino, Anthony J.; Montague, Stephen; Sniegowski, Jeffry J.; Smith, James H.; McWhorter, Paul J.
1998-01-01
A method is disclosed for photolithographically defining device features up to the resolution limit of an auto-focusing projection stepper when the device features are to be formed in a wafer cavity at a depth exceeding the depth of focus of the stepper. The method uses a focusing cavity located in a die field at the position of a focusing light beam from the auto-focusing projection stepper, with the focusing cavity being of the same depth as one or more adjacent cavities wherein a semiconductor device is to be formed. The focusing cavity provides a bottom surface for referencing the focusing light beam and focusing the stepper at a predetermined depth below the surface of the wafer, whereat the device features are to be defined. As material layers are deposited in each device cavity to build up a semiconductor structure such as a microelectromechanical system (MEMS) device, the same material layers are deposited in the focusing cavity, raising the bottom surface and re-focusing the stepper for accurately defining additional device features in each succeeding material layer. The method is especially applicable for forming MEMS devices within a cavity or trench and integrating the MEMS devices with electronic circuitry fabricated on the wafer surface.
NASA Astrophysics Data System (ADS)
Bertholet, Jenny; Toftegaard, Jakob; Hansen, Rune; Worm, Esben S.; Wan, Hanlin; Parikh, Parag J.; Weber, Britta; Høyer, Morten; Poulsen, Per R.
2018-03-01
The purpose of this study was to develop, validate and clinically demonstrate fully automatic tumour motion monitoring on a conventional linear accelerator by combined optical and sparse monoscopic imaging with kilovoltage x-rays (COSMIK). COSMIK combines auto-segmentation of implanted fiducial markers in cone-beam computed tomography (CBCT) projections and intra-treatment kV images with simultaneous streaming of an external motion signal. A pre-treatment CBCT is acquired with simultaneous recording of the motion of an external marker block on the abdomen. The 3-dimensional (3D) marker motion during the CBCT is estimated from the auto-segmented positions in the projections and used to optimize an external correlation model (ECM) of internal motion as a function of external motion. During treatment, the ECM estimates the internal motion from the external motion at 20 Hz. KV images are acquired every 3 s, auto-segmented, and used to update the ECM for baseline shifts between internal and external motion. The COSMIK method was validated using Calypso-recorded internal tumour motion with simultaneous camera-recorded external motion for 15 liver stereotactic body radiotherapy (SBRT) patients. The validation included phantom experiments and simulations hereof for 12 fractions and further simulations for 42 fractions. The simulations compared the accuracy of COSMIK with ECM-based monitoring without model updates and with model updates based on stereoscopic imaging as well as continuous kilovoltage intrafraction monitoring (KIM) at 10 Hz without an external signal. Clinical real-time tumour motion monitoring with COSMIK was performed offline for 14 liver SBRT patients (41 fractions) and online for one patient (two fractions). The mean 3D root-mean-square error for the four monitoring methods was 1.61 mm (COSMIK), 2.31 mm (ECM without updates), 1.49 mm (ECM with stereoscopic updates) and 0.75 mm (KIM). COSMIK is the first combined kV/optical real-time motion monitoring method used clinically online on a conventional accelerator. COSMIK gives less imaging dose than KIM and is in addition applicable when the kV imager cannot be deployed such as during non-coplanar fields.
The Relationship between Affective States and Dialog Patterns during Interactions with AutoTutor
ERIC Educational Resources Information Center
Graesser, Arthur C.; D'Mello, Sidney K.; Craig, Scotty D.; Witherspoon, Amy; Sullins, Jeremiah; McDaniel, Bethany; Gholson, Barry
2008-01-01
Relations between emotions (affect states) and learning have recently been explored in the context of AutoTutor. AutoTutor is a tutoring system on the Internet that helps learners construct answers to difficult questions by interacting with them in natural language. AutoTutor has an animated conversation agent and a dialog management facility that…
AutoTutor and Family: A Review of 17 Years of Natural Language Tutoring
ERIC Educational Resources Information Center
Nye, Benjamin D.; Graesser, Arthur C.; Hu, Xiangen
2014-01-01
AutoTutor is a natural language tutoring system that has produced learning gains across multiple domains (e.g., computer literacy, physics, critical thinking). In this paper, we review the development, key research findings, and systems that have evolved from AutoTutor. First, the rationale for developing AutoTutor is outlined and the advantages…
Electrical Systems. Auto Mechanics Curriculum Guide Module 2. Instructor's Guide.
ERIC Educational Resources Information Center
Hevel, David; Donovan, Roger
This document is one of a series of modules in the Missouri Auto Mechanics Curriculum Guide, which is based on 144 basic auto mechanics competencies identified on the Missouri Auto Mechanics Competency Profile. The instructor's materials in this document are for a 14-unit secondary education course. The following units are included: (1) principles…
Manual Drive Train and Axles. Auto Mechanics Curriculum Guide Module 7. Instructor's Guide.
ERIC Educational Resources Information Center
Colesworthy, Robert; Donovan, Roger
This document is one of a series of modules in the Missouri Auto Mechanics Curriculum Guide, which is based on 144 basic auto mechanics competencies identified on the Missouri Auto Mechanics Competency Profile. The instructor's materials in this document are for a 13-unit secondary education course. The following units are included: (1)…
77 FR 16227 - Frank Myers AutoMaxx, LLC; Analysis of Proposed Consent Order To Aid Public Comment
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-20
... FEDERAL TRADE COMMISSION [File No. 112 3206] Frank Myers AutoMaxx, LLC; Analysis of Proposed... ``Frank Myers AutoMaxx, File No. 112 3206'' on your comment, and file your comment online at https... April 16, 2012. Write ``Frank Myers AutoMaxx, File No. 112 3206'' on your comment. Your comment...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-25
... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-71,863] United Auto Workers Local... workers and former workers of United Auto Workers Local 1999, Oklahoma City, Oklahoma (the subject firm... Auto Workers Local 1999, Oklahoma City, Oklahoma, was based on the findings that the workers at the...
Preparing Writing Centers and Tutors for Literacy Mediation for Working Class Campus-Staff
ERIC Educational Resources Information Center
Oslund, Christy M.
2011-01-01
This study grew out of the realization that implicit literacy expectations between working class United Auto Workers (UAW) staff and professional class staff were complicating the filling out and filing of a position audit form. Professional class supervisors had designed the form as a measure of fairness, in that each UAW employee on campus was…
A New Tool for Classifying Small Solar System Objects
NASA Astrophysics Data System (ADS)
Desfosses, Ryan; Arel, D.; Walker, M. E.; Ziffer, J.; Harvell, T.; Campins, H.; Fernandez, Y. R.
2011-05-01
An artificial intelligence program, AutoClass, which was developed by NASA's Artificial Intelligence Branch, uses Bayesian classification theory to automatically choose the most probable classification distribution to describe a dataset. To investigate its usefulness to the Planetary Science community, we tested its ability to reproduce the taxonomic classes as defined by Tholen and Barucci (1989). Of the 406 asteroids from the Eight Color Asteroid Survey (ECAS) we chose for our test, 346 were firmly classified and all but 3 (<1%) were classified by Autoclass as they had been in the previous classification system (Walker et al., 2011). We are now applying it to larger datasets to improve the taxonomy of currently unclassified objects. Having demonstrated AutoClass's ability to recreate existing classification effectively, we extended this work to investigations of albedo-based classification systems. To determine how predictive albedo can be, we used data from the Infrared Astronomical Satellite (IRAS) database in conjunction with the large Sloan Digital Sky Survey (SDSS), which contains color and position data for over 200,000 classified and unclassified asteroids (Ivesic et al., 2001). To judge our success we compared our results with a similar approach to classifying objects using IRAS albedo and asteroid color by Tedesco et al. (1989). Understanding the distribution of the taxonomic classes is important to understanding the history and evolution of our Solar System. AutoClass's success in categorizing ECAS, IRAS and SDSS asteroidal data highlights its potential to scan large domains for natural classes in small solar system objects. Based upon our AutoClass results, we intend to make testable predictions about asteroids observed with the Wide-field Infrared Survey Explorer (WISE).
; margin-left: auto; margin-right: auto; } .slick-track:before, .slick-track:after { display: table : auto; border: 1px solid transparent; } .slick-arrow.slick-hidden { display: none;
Subasic, Djemo; Karamehic, Jasenko; Gavrankapetanovic, Faris; Hodzic, Harun; Kasumovic, Mersija; Delic-Sarac, Marina; Prljaca-Zecevic, Lamija
2009-01-01
The basis of autoimmune diseases such as SLE (Systemic Lupus Eritematodes), Sjogren's syndrome, scleroderma, dermatomyositis and polymiositis is the creation of auto-antibodies to the following specific extractable nuclear antigens (ENA):Jo-1, Ssl-70, SS-A, SS-B, Sm and Sm/RNPs. Some of these antigens are in fact enzymes (Jo-1-histidil-tRNA synthetase, Scl-70-topoisomerase) which are inhibited by specific autoantibodies--this leads to disturbance in the metabolism of DNA and protein biosynthesis. During 2009, we analyzed total of 87 serum samples of patients suspected for autoimmune disorder using ANA-IFA and ELISA-ENA-6 methods. After establishing IFA-ANA positivity (83.9%), all serum specimens; ANA positive and negative, were subtypized by ELISA ENA-6 test. Analysis showed the highest incidence of anti-SS-A (56%), and incidence of anti-SS-B (29.8%), anti-Sm/ RNP (11.5%), anti-Jo-1 (2.3%) and anti-Scl-70 (1,1%) auto-antibodies. Also, 78.5% of IFA-ANA negative serum specimens showed high level of positivity (212.50 and 277.0 IU/ml) to SS-A (78.5%) and SS-B (21.4%) antigenes using ELISA-ENA-6 subtypization. Following these results, we conclude that it is necessary to introduce Western blot confirmation testing. After comparing with other clinical findings, we diagnosed the following autoimmune diseases: SLE, Sjogren's syndrome and dermatomiosytis.
Clinical utility of anti-p53 auto-antibody: Systematic review and focus on colorectal cancer
Suppiah, Aravind; Greenman, John
2013-01-01
Mutation of the p53 gene is a key event in the carcinogenesis of many different types of tumours. These can occur throughout the length of the p53 gene. Anti-p53 auto-antibodies are commonly produced in response to these p53 mutations. This review firstly describes the various mechanisms of p53 dysfunction and their association with subsequent carcinogenesis. Following this, the mechanisms of induction of anti-p53 auto-antibody production are shown, with various hypotheses for the discrepancies between the presence of p53 mutation and the presence/absence of anti-p53 auto-antibodies. A systematic review was performed with a descriptive summary of key findings of each anti-p53 auto-antibody study in all cancers published in the last 30 years. Using this, the cumulative frequency of anti-p53 auto-antibody in each cancer type is calculated and then compared with the incidence of p53 mutation in each cancer to provide the largest sample calculation and correlation between mutation and anti-p53 auto-antibody published to date. Finally, the review focuses on the data of anti-p53 auto-antibody in colorectal cancer studies, and discusses future strategies including the potentially promising role using anti-p53 auto-antibody presence in screening and surveillance. PMID:23922463
Földes-Papp, Zeno; Baumann, Gerd; Demel, Ulrike; Tilz, Gernot P
2004-04-01
Many theoretical models of molecular interactions, biochemical and chemical reactions are described on the single-molecule level, although our knowledge about the biochemical/chemical structure and dynamics primarily originates from the investigation of many-molecule systems. At present, there are four experimental platforms to observe the movement and the behavior of single fluorescent molecules: wide-field epi-illumination, near-field optical scanning, and laser scanning confocal and multiphoton microscopy. The platforms are combined with analytical methods such as fluorescence resonance energy transfer (FRET), fluorescence auto-or two-color cross-correlation spectroscopy (FCS), fluorescence polarizing anisotropy, fluorescence quenching and fluorescence lifetime measurements. The original contribution focuses on counting and characterization of freely diffusing single molecules in a single-phase like a solution or a membrane without hydrodynamic flow, immobilization or burst size analysis of intensity traces. This can be achieved, for example, by Fluorescence auto- or two-color cross-Correlation Spectroscopy as demonstrated in this original article. Three criteria (Földes-Papp (2002) Pteridines, 13, 73-82; Földes-Papp et al. (2004a) J. Immunol. Meth., 286, 1-11; Földes-Papp et al. (2004b) J. Immunol. Meth., 286, 13-20) are discussed for performing continuous measurements with one and the same single (individual) molecule, freely diffusing in a solution or a membrane, from sub-milliseconds up to severals hours. The 'algorithms' developed for single-molecule fluorescence detection are called the 'selfsame single-fluorescent-molecule regime'. An interesting application of the results found is in the field of immunology. The application of the theory to experimental results shows that the theory is consistent with the experiments. The exposition of the novel ideas on Single (Solution)-Phase Single-Molecule Fluorescence auto- or two-color cross-Correlation Spectroscopy (SPSM-FCS) are comprehensively presented. As technology continues to improve, the limits of what FCS/FCCS is being asked to do are concomitantly pushed.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-07
...-AA87 Security Zone; 23rd Annual North American International Auto Show, Detroit River, Detroit, MI... officials at the 23rd Annual North American International Auto Show (NAIAS) being held at Cobo Hall in... 23rd Annual North American International Auto Show (NAIAS) being held at Cobo Hall in downtown Detroit...
A phase II study of V-BEAM as conditioning regimen before second auto-SCT for multiple myeloma.
Wang, T-F; Fiala, M A; Cashen, A F; Uy, G L; Abboud, C N; Fletcher, T; Wu, N; Westervelt, P; DiPersio, J F; Stockerl-Goldstein, K E; Vij, R
2014-11-01
High-dose melphalan has been the standard conditioning regimen for auto-SCT in multiple myeloma (MM) for decades. A more effective conditioning regimen may induce deeper responses and longer remission duration. It is especially needed in the setting of second auto-SCT, which rarely achieves comparable results with the first auto-SCT using the same conditioning regimen. Here we conducted a phase II study to investigate the efficacy and safety of a conditioning regimen V-BEAM (bortezomib-BEAM) before second auto-SCT for multiple myeloma. Ten patients were enrolled from September 2012 to May 2013. The CR rate at day +100 after auto-SCT was 75%; all except for one patient remained in remission after a median follow-up of 6 months. Three patients developed Clostridium difficile infection. Two patients died within the first 30 days of auto-SCT from neutropenic colitis and overwhelming sepsis, respectively. Due to the high rate of morbidity and mortality, the study was terminated after 10 patients. In summary, although the conditioning regimen V-BEAM before second auto-SCT for MM provided promising responses, it was associated with unexpected treatment-related toxicity and should not be investigated further without modifications.
Haemolytic anaemia to the alpha-interferon treatment: a proposed mechanism.
Barbolla, L; Paniagua, C; Outeiriño, J; Prieto, E; Sánchez Fayos, J
1993-01-01
Auto-immune haemolytic anaemia (AIHA) has been found in a case of alpha-interferon treatment. Serum antibody and eluate were positive in the absence of the drug. Although the patient recovered after the treatment was stopped, DAGT remained positive for at least 8 months. The mechanism proposed to explain why this drug induced AIHA is similar to that proposed for alpha-methyl-dopa. Drugs could alter the red cell membrane and impair the immune system. Such changes have been observed with alpha-interferon and were related with increased autoimmunity.
Momentum conserving Brownian dynamics propagator for complex soft matter fluids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Padding, J. T.; Briels, W. J.
2014-12-28
We present a Galilean invariant, momentum conserving first order Brownian dynamics scheme for coarse-grained simulations of highly frictional soft matter systems. Friction forces are taken to be with respect to moving background material. The motion of the background material is described by locally averaged velocities in the neighborhood of the dissolved coarse coordinates. The velocity variables are updated by a momentum conserving scheme. The properties of the stochastic updates are derived through the Chapman-Kolmogorov and Fokker-Planck equations for the evolution of the probability distribution of coarse-grained position and velocity variables, by requiring the equilibrium distribution to be a stationary solution.more » We test our new scheme on concentrated star polymer solutions and find that the transverse current and velocity time auto-correlation functions behave as expected from hydrodynamics. In particular, the velocity auto-correlation functions display a long time tail in complete agreement with hydrodynamics.« less
Auto-tuning for NMR probe using LabVIEW
NASA Astrophysics Data System (ADS)
Quen, Carmen; Pham, Stephanie; Bernal, Oscar
2014-03-01
Typical manual NMR-tuning method is not suitable for broadband spectra spanning several megahertz linewidths. Among the main problems encountered during manual tuning are pulse-power reproducibility, baselines, and transmission line reflections, to name a few. We present a design of an auto-tuning system using graphic programming language, LabVIEW, to minimize these problems. The program uses a simplified model of the NMR probe conditions near perfect tuning to mimic the tuning process and predict the position of the capacitor shafts needed to achieve the desirable impedance. The tuning capacitors of the probe are controlled by stepper motors through a LabVIEW/computer interface. Our program calculates the effective capacitance needed to tune the probe and provides controlling parameters to advance the motors in the right direction. The impedance reading of a network analyzer can be used to correct the model parameters in real time for feedback control.
Auto-immune hepatitis following delivery.
Saini, Vandana; Gupta, Mamta; Mishra, S K
2013-05-01
Auto-immune hepatitis first presenting in the early postpartum period is rare. Immunosuppressive effects of pregnancy result in delayed manifestation of auto-immune hepatitis, and in established cases, the spontaneous improvements are there. Auto-immune hepatitis should be considered in the differential diagnosis of liver dysfunction first presenting in the early postpartum period. A case of postpartum hepatitis of auto-immune aetiology is being presented here. It is disease of unknown aetiology, characterised by inflammation of liver (as evidenced by raised serum transaminases, presence of interface hepatitis on histological examination), hypergammaglobulinaemia (> 1.5 times normal), presence of auto-antibodies [(antinuclear antibodies (ANA)], smooth muscle antibody (SMA) and antibody to liver-kidney microsome type 1 (LKM1) in the absence of viral markers ie, hepatitis B (HBsAg) and C (AntiHCV) and excellent response to corticosteroid therapy.
NASA Astrophysics Data System (ADS)
Osmaston, Miles F.
2013-09-01
Our preceding paper "Implementing Maxwell's aether......." (Paper I) concluded:- (A) Maxwell's aether, ignored in Relativity, is a massless, quasi-superfluid continuum of extremely high negative charge density; (B) Fundamental particles are not infinitesimal singularities within the aether but develop their mass by being `made out of it' (hence the name Continuum Theory) as finite-sized vortical constructs of its motion. So reproduction (`auto-creation') of more of them requires only the addition of suitable dynamical energy, with Ampere's law providing charge-coupling in shear to get rotations. (C) In the resulting gravitational process, generating the Newtonian force simultaneously also generates a radial electric field, the Gravity-Electric (G-E) field, whose action on astronomical plasmas could explain the flat tangential velocity profiles of spiral galaxies without resort to Cold Dark Matter (CDM) if outward disc flow is present. One of the objectives here is to provide that flow by axial infall and to examine its consequences. But first, if particles are `made out of aether' the associated random aether-charge motion will generate radiation (the CMB) and impose four distance-cumulative, wavelength-independent transmission effects upon electromagnetic waves. One of these - a redshift - we see here as the cosmic redshift, plus intrinsic redshifts in stellar and galaxy `atmospheres'. Such a redshift appears to have been reliably observed with caesium clocks over long ground-level paths in 1968 but, lacking an appreciation of its mechanism, its wide significance was doubted. In fact, our extrapolation to intergalactic conditions dispenses with the BigBang. The other 3 transmission effects are:- spectral line broadening, scattering and attenuation, each of which has significant astronomical/cosmological expression. If the cosmic redshift is not a velocity, the reason for Dark Energy vanishes. In the resulting no-expansion cosmology the Universe was originally equipped with randomly moving aether, from whose motion and energy content the entire mass content of the Universe has grown over time by auto-creation, the local rate of which experiences positive feedback and acceleration as gravitational accumulations drive energy levels higher. Hence the clumpiness of galaxy distributions. The infall of cosmogonally young material from the auto-creation auras of clusters has 3 major implications. (1) It completely inverts the Big Bang perspective that lowmetallicity material, widespread in galaxy haloes, is very ancient. (2) Quasi-axial infall of such broadly neutral material (mostly H) onto a Spiral will spread out in the galactic plane, driven radially from the ionizing bulge by the G-E field, maintaining constant tangential velocity; all without CDM. This pattern means that the arms, although trailing, are actually being blown outward (unwrapping). See Paper I for detail. For such ongoing disruption of Spirals to prevail so widely means that originally each must have started life as an a.m.-conserving, tightly-wound spiral of mostly neutral, cosmogonically young material (mainly H), in which G-E field action was minimal until star formation and ionization had set in. (3) In cluster interiors, other cluster members may deflect the two infall streams as they converge onto a Spiral, introducing a dynamical rotational couple near the centre, with an axis roughly in the galactic plane, to produce a Barred Spiral. Cessation of infall then results in endwise collapse of that bar, yielding a fattened Elliptical. Those are indeed typically concentrated in the centres of clusters and show a dearth of active star formation, consistent with being deprived of young infall. We present images and diagrams in support and elaboration of (2) and (3). The CT model for quasars provides large intrinsic redshift by the CT analogue of Transverse Doppler Effect and offers light-element synthesis by the evolutionary precipitation of a runaway rotational shrinkage, with mass annihilation and emission of a GRB. Of special interest, relative to the arm's-length nature of BigBang cosmology, is that continuous auto-creation (CAC) cosmology is in principle available near-by for direct study and the development of strong observational constraints. In the context of (1), the very low metallicity (Pop II) of globular (star) clusters abundantly present in the haloes of galaxies points to them being (infallen?) local concentrations of quite young auto-creation. In that case the `blue straggler' stars more recently formed in their core regions may be our youngest examples of ongoing auto-creation. In summary, CT offers a much more directly observable Universe, with no Big Bang, CDM, or Dark Energy, and a CMB that records the true temperature of intergalactic space along the path taken by the radiation. Its closely cavity-radiation character arises from the random aether's transmission-related opacity (Olbers' Paradox) of the infinite CT Universe. Fundamentally, the aether's random motion constitutes all-penetrating random electromagnetic excitation at the atomic scale that may offer the accommodation between classical physics and stochastic quantum electrodynamics so long obstructed by Relativity Theory.
Hybrid MV-kV 3D respiratory motion tracking during radiation therapy with low imaging dose
NASA Astrophysics Data System (ADS)
Yan, Huagang; Li, Haiyun; Liu, Zhixiang; Nath, Ravinder; Liu, Wu
2012-12-01
A novel real-time adaptive MV-kV imaging framework for image-guided radiation therapy is developed to reduce the thoracic and abdominal tumor targeting uncertainty caused by respiration-induced intrafraction motion with ultra-low patient imaging dose. In our method, continuous stereoscopic MV-kV imaging is used at the beginning of a radiation therapy delivery for several seconds to measure the implanted marker positions. After this stereoscopic imaging period, the kV imager is switched off except for the times when no fiducial marker is detected in the cine-MV images. The 3D time-varying marker positions are estimated by combining the MV 2D projection data and the motion correlations between directional components of marker motion established from the stereoscopic imaging period and updated afterwards; in particular, the most likely position is assumed to be the position on the projection line that has the shortest distance to the first principal component line segment constructed from previous trajectory points. An adaptive windowed auto-regressive prediction is utilized to predict the marker position a short time later (310 ms and 460 ms in this study) to allow for tracking system latency. To demonstrate the feasibility and evaluate the accuracy of the proposed method, computer simulations were performed for both arc and fixed-gantry deliveries using 66 h of retrospective tumor motion data from 42 patients treated for thoracic or abdominal cancers. The simulations reveal that using our hybrid approach, a smaller than 1.2 mm or 1.5 mm root-mean-square tracking error can be achieved at a system latency of 310 ms or 460 ms, respectively. Because the kV imaging is only used for a short period of time in our method, extra patient imaging dose can be reduced by an order of magnitude compared to continuous MV-kV imaging, while the clinical tumor targeting accuracy for thoracic or abdominal cancers is maintained. Furthermore, no additional hardware is required with the proposed method.
The Strategic Design of Reward Systems.
1982-10-01
AuTO1 , 8 CO NTRACT Ok .NANT NUMO lll , Edward E. Lawler III N-00014-81-K-0048 9 PERFORMING ORGANIZATION NAME AND ADORErS 10. PROGRAM ELEMENT...SUPPLEMENTARY NOTES .iL L:~ 19 KEY WORDS (Continue on reveres side It necessary and Identify by block number) A Pay, performance appraisal, motivation...retention, culture development:, and skill development are considered. The relationship between these object iwv and such design options as performance pay
2017-10-18
Fermentation Syndrome in the Psychiatric Evaluation of Patients with Suspected Alcohol Use Disorder Sb. GRANT NUMBER Sc. PROGRAM ELEMENT NUMBER 6...by ANSI Std. Z39.18 Adobe Professional 7. 0 Introduction Gut Fermentation Syndrome, also known as auto- brewery syndrome, is a phenomenon not well...patient stated abstinence from alcohol use and that Gut Fermentation Syndrome was the cause of continually elevated blood alcohol levels. We will
A Needs Assessment of Entry-Level Competencies for Modification of an Auto Body Repair Curriculum.
ERIC Educational Resources Information Center
Borremans, Robert T.
A needs assessment was conducted to determine job tasks relevant for entry-level auto body repairers as a basis for updating the Auto Body Program at Blackhawk Technical Institute (BTI). A survey was mailed to 86 local auto body shops, asking employers to rank 149 tasks in 11 duty areas in terms of importance and frequency performed. Study…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-05
... has executed on average per trading day (excluding partial trading days) in AutoEx or Order Delivery... (``AutoEx'') shall mean only those executed shares of the ETP Holder that are submitted in AutoEx mode... period, a combined ADV in both AutoEx and Order Delivery of at least 11.5 million shares, of which at...
He, Ping; Tan, De-Li; Liu, Hong-Xiang; Lv, Feng-Lin; Wu, Wei
2015-04-01
The short isoform of Rho guanine nucleotide exchange factor ARHGEF5 is known as TIM, which plays diverse roles in, for example, tumorigenesis, neuronal development and Src-induced podosome formation through the activation of its substrates, the Rho family of GTPases. The activation is auto-inhibited by a putative helix N-terminal to the DH domain of TIM, which is stabilized by the intramolecular interaction of C-terminal SH3 domain with a poly-proline sequence between the putative helix and the DH domain. In this study, we systematically investigated the structural basis, energetic landscape and biological implication underlying TIM auto-inhibition by using atomistic molecular dynamics simulations and binding free energy analysis. The computational study revealed that the binding of SH3 domain to poly-proline sequence is the prerequisite for the stabilization of TIM auto-inhibition. Thus, it is suggested that targeting SH3 domain with competitors of the poly-proline sequence would be a promising strategy to relieve the auto-inhibitory state of TIM. In this consideration, we rationally designed a number of peptide aptamers for competitively inhibiting the SH3 domain based on modeled TIM structure and computationally generated data. Peptide binding test and guanine nucleotide exchange analysis solidified that these designed peptides can both bind to the SH3 domain potently and activate TIM-catalyzed RhoA exchange reaction effectively. Interestingly, a positive correlation between the peptide affinity and induced exchange activity was observed. In addition, separate mutation of three conserved residues Pro49, Pro52 and Lys54 - they are required for peptide recognition by SH3 domain -- in a designed peptide to Ala would completely abolish the capability of this peptide activating TIM. All these come together to suggest an intrinsic relationship between peptide binding to SH3 domain and the activation of TIM. Copyright © 2015 Elsevier B.V. and Société Française de Biochimie et Biologie Moléculaire (SFBBM). All rights reserved.
Anti-pentraxin 3 auto-antibodies might be protective in lupus nephritis: a large cohort study.
Yuan, Mo; Tan, Ying; Pang, Yun; Li, Yong-Zhe; Song, Yan; Yu, Feng; Zhao, Ming-Hui
2017-11-01
Anti-pentraxin 3 (PTX3) auto-antibodies were found to be associated with the absence of renal involvement in systemic lupus erythematosus (SLE). This study is to investigate the prevalence of anti-PTX3 auto-antibodies and their clinical significance based on a large Chinese lupus nephritis cohort. One hundred and ninety-six active lupus nephritis patients, 150 SLE patients without clinical renal involvement, and 100 healthy controls were enrolled. Serum anti-PTX3 auto-antibodies and PTX3 levels were screened by enzyme-linked immunosorbent assay (ELISA). The associations between anti-PTX3 auto-antibodies and clinicopathological parameters in lupus nephritis were further analyzed. Anti-PTX3 auto-antibodies were less prevalent in active lupus nephritis patients compared with SLE without renal involvement (19.4% (38/196) versus 40.7% (61/150), p < .001). The serum levels of anti-PTX3 auto-antibodies were negatively correlated with proteinuria in lupus nephritis (r = -.143, p = .047). The levels of proteinuria, serum creatinine, and the prevalence of thrombotic microangiopathy were significantly higher in patients with higher PTX3 levels (≥3.207 ng/ml) and without anti-PTX3 auto-antibodies compared with patients with lower PTX3 levels (<3.207 ng/ml) and with anti-PTX3 auto-antibodies (4.79 (3.39-8.28) versus 3.95 (1.78-7.0), p = .03; 168.84 ± 153.63 versus 101.44 ± 47.36, p = .01; 34.1% (14/41) versus 0% (0/9), p = .04; respectively). Anti-PTX3 auto-antibodies were less prevalent in active lupus nephritis patients compared with SLE without renal involvement and associated with less severe renal damage, especially with the combined evaluation of serum PTX3 levels.
Akintunde, Adeseye A; Oloyede, Taiwo W
2017-11-01
To determine occupational association with metabolic syndrome among auto technicians and school teachers. One hundred and sixty six subjects were selected for this study. Clinical data was obtained while laboratory investigations including plasma glucose and lipid profile were performed. Statistical analysis was done with SPSS 20.0. P<0.05 was taken as statistically significant. School teachers had significantly higher mean total cholesterol and LDL-cholesterol compared to auto technicians. Mean serum triglycerides was significantly higher among auto-technicians compared to school teachers in this study. The prevalence of some conventional cardiovascular risk factors was significantly higher among auto-technicians compared to school teachers: Impaired blood glucose (9.6% vs. 1.2%, p<0.05), hypertriglyceridaemia (18.1% vs. 7.2%, p<0.05) and low HDL-Cholesterol (47.0% vs. 37.3%, p<0.05) respectively. However elevated LDL-cholesterol (56.6% vs. 32.5%, p<0.05) was significantly more common among school teachers compared to auto-technicians. Based on the WHO and the Harmonized criteria, metabolic syndrome was more frequent among auto-technicians compared to school teachers. (8.4% vs. 1.2% and 19.3% vs. 7.2% respectively, p<0.05) CONCLUSION: The prevalence of metabolic syndrome appears to be significantly higher among auto technicians despite their high level of physical activity, exertion and education compared to teachers. This may be related to the increased occupational exposure to organic and inorganic materials from dust particles, oil and oil related matter and particulate matter among auto technicians. Prompt definitive evaluation of this concept and appropriate health education to encourage safety mechanism can reduce this burden of metabolic syndrome among auto technicians in Nigeria. Copyright © 2016 Diabetes India. Published by Elsevier Ltd. All rights reserved.
2017-01-01
With the aim to investigate the outcome of tandem high-dose chemotherapy and autologous stem cell transplantation (HDCT/auto-SCT) for high-grade gliomas (HGGs), we retrospectively reviewed the medical records of 30 patients with HGGs (16 glioblastomas, 7 anaplastic astrocytomas, and 7 other HGGs) between 2006 and 2015. Gross or near total resection was possible in 11 patients. Front-line treatment after surgery was radiotherapy (RT) in 14 patients and chemotherapy in the remaining 16 patients including 3 patients less than 3 years of age. Eight of 12 patients who remained progression free and 5 of the remaining 18 patients who experienced progression during induction treatment underwent the first HDCT/auto-SCT with carboplatin + thiotepa + etoposide (CTE) regimen and 11 of them proceeded to the second HDCT/auto-SCT with cyclophosphamide + melphalan (CyM) regimen. One patient died from hepatic veno-occlusive disease (VOD) during the second HDCT/auto-SCT; otherwise, toxicities were manageable. Four patients in complete response (CR) and 3 of 7 patients in partial response (PR) or second PR at the first HDCT/auto-SCT remained event free: however, 2 patients with progressive tumor experienced progression again. The probabilities of 3-year overall survival (OS) after the first HDCT/auto-SCT in 11 patients in CR, PR, or second PR was 58.2% ± 16.9%. Tumor status at the first HDCT/auto-SCT was the only significant factor for outcome after HDCT/auto-SCT. There was no difference in survival between glioblastoma and other HGGs. This study suggests that the outcome of HGGs in children and adolescents after HDCT/auto-SCT is encouraging if the patient could achieve CR or PR before HDCT/auto-SCT. PMID:28049229
Post-autologous transplant maintenance therapies in lymphoid malignancies: are we there yet?
Epperla, N; Fenske, T S; Lazarus, H M; Hamadani, M
2015-11-01
Disease relapse after autologous hematopoietic transplant (auto-HCT) remains the number one cause of post-transplant therapy failure and mortality. The last decade has seen a proliferation of clinical studies looking at the prevention of post-auto-HCT therapy failure with various maintenance strategies. The benefit of such therapies is in turn dependent on disease histology and timing of transplantation. Although high dose therapy (HDT) provides durable responses in chemosensitive relapsed diffuse large B-cell lymphoma (DLBCL), a sizable subset experiences disease relapse. Unfortunately, the addition of rituximab as a post-auto-HCT maintenance strategy did not improve survival outcomes. The preliminary results with programmed death -1 (PD-1) Ab as post-auto maintenance in DLBCL is promising but requires randomized validation. In follicular lymphoma, the 5- and 10-year PFS rates are ~60% and 31%, respectively. Although the addition of rituximab improved PFS, there is no survival benefit, to date. Disease relapse after auto-HCT in mantle cell lymphoma (MCL) is not uncommon. Rituximab maintenance in this setting provides a PFS benefit. Given the poor prognosis of post-auto-HCT failures in MCL, maintenance can be considered on a case-by-case basis. In chemosensitive relapsed Hodgkin lymphoma, addition of brentuximab vedotin after auto-HCT improved 2-year PFS (65 vs 45%) and can be considered as an option for maintenance therapy post auto-HCT, in select higher risk patients. Ongoing trials evaluating the efficacy of post-auto-HCT maintenance with novel agents (for example, immunomodulators, proteasome inhibitors, PD-1 inhibitors, Bruton's tyrosine kinase inhibitors and so on) will likely change the practice landscape for lymphoma patients following HDT and auto-HCT.
Impact of single-site axonal GABAergic synaptic events on cerebellar interneuron activity.
de San Martin, Javier Zorrilla; Jalil, Abdelali; Trigo, Federico F
2015-12-01
Axonal ionotropic receptors are present in a variety of neuronal types, and their function has largely been associated with the modulation of axonal activity and synaptic release. It is usually assumed that activation of axonal GABA(A)Rs comes from spillover, but in cerebellar molecular layer interneurons (MLIs) the GABA source is different: in these cells, GABA release activates presynaptic GABA(A) autoreceptors (autoRs) together with postsynaptic targets, producing an autoR-mediated synaptic event. The frequency of presynaptic, autoR-mediated miniature currents is twice that of their somatodendritic counterparts, suggesting that autoR-mediated responses have an important effect on interneuron activity. Here, we used local Ca(2+) photolysis in MLI axons of juvenile rats to evoke GABA release from individual varicosities to study the activation of axonal autoRs in single release sites. Our data show that single-site autoR conductances are similar to postsynaptic dendritic conductances. In conditions of high [Cl(-)](i), autoR-mediated conductances range from 1 to 5 nS; this corresponds to ∼30-150 GABA(A) channels per presynaptic varicosity, a value close to the number of channels in postsynaptic densities. Voltage responses produced by the activation of autoRs in single varicosities are amplified by a Na(v)-dependent mechanism and propagate along the axon with a length constant of 91 µm. Immunolabeling determination of synapse location shows that on average, one third of the synapses produce autoR-mediated signals that are large enough to reach the axon initial segment. Finally, we show that single-site activation of presynaptic GABA(A) autoRs leads to an increase in MLI excitability and thus conveys a strong feedback signal that contributes to spiking activity. © 2015 Zorrilla de San Martin et al.
Impact of single-site axonal GABAergic synaptic events on cerebellar interneuron activity
Zorrilla de San Martin, Javier; Jalil, Abdelali
2015-01-01
Axonal ionotropic receptors are present in a variety of neuronal types, and their function has largely been associated with the modulation of axonal activity and synaptic release. It is usually assumed that activation of axonal GABAARs comes from spillover, but in cerebellar molecular layer interneurons (MLIs) the GABA source is different: in these cells, GABA release activates presynaptic GABAA autoreceptors (autoRs) together with postsynaptic targets, producing an autoR-mediated synaptic event. The frequency of presynaptic, autoR-mediated miniature currents is twice that of their somatodendritic counterparts, suggesting that autoR-mediated responses have an important effect on interneuron activity. Here, we used local Ca2+ photolysis in MLI axons of juvenile rats to evoke GABA release from individual varicosities to study the activation of axonal autoRs in single release sites. Our data show that single-site autoR conductances are similar to postsynaptic dendritic conductances. In conditions of high [Cl−]i, autoR-mediated conductances range from 1 to 5 nS; this corresponds to ∼30–150 GABAA channels per presynaptic varicosity, a value close to the number of channels in postsynaptic densities. Voltage responses produced by the activation of autoRs in single varicosities are amplified by a Nav-dependent mechanism and propagate along the axon with a length constant of 91 µm. Immunolabeling determination of synapse location shows that on average, one third of the synapses produce autoR-mediated signals that are large enough to reach the axon initial segment. Finally, we show that single-site activation of presynaptic GABAA autoRs leads to an increase in MLI excitability and thus conveys a strong feedback signal that contributes to spiking activity. PMID:26621773
Malignant Mesothelioma in a Motor Vehicle Mechanic.
Meisenkothen, Christopher
2017-02-01
Case reports remain an important source of data in the debate over the carcinogenic effect of asbestos-containing automotive friction products. This report documents a case of pleural mesothelioma accompanied by asbestos bodies in the lung tissue of a career auto mechanic with no other known sources of exposure. Previously unreported historical and contemporary exposure data are also discussed in the context of providing additional support for the proposition that work with asbestos-containing automotive products presents a risk of significant exposure. While there remains a body of negative epidemiology that fails to find an increased risk of disease among auto workers, those data must be approached with caution. Many of those studies have drawn technical criticisms, which are beyond the scope of this report, but they remain a key part of the legal defense mounted by defendant-companies who are involved in asbestos-related litigation. This ongoing debate provides the context for the continued relevance of case reports such as this one, as well as the presentation of new and previously unpublished exposure data.
CAD/CAM interface design of excimer laser micro-processing system
NASA Astrophysics Data System (ADS)
Jing, Liang; Chen, Tao; Zuo, Tiechuan
2005-12-01
Recently CAD/CAM technology has been gradually used in the field of laser processing. The excimer laser micro-processing system just identified G instruction before CAD/CAM interface was designed. However the course of designing a part with G instruction for users is too hard. The efficiency is low and probability of making errors is high. By secondary development technology of AutoCAD with Visual Basic, an application was developed to pick-up each entity's information in graph and convert them to each entity's processing parameters. Also an additional function was added into former controlling software to identify these processing parameters of each entity and realize continue processing of graphic. Based on the above CAD/CAM interface, Users can design a part in AutoCAD instead of using G instruction. The period of designing a part is sharply shortened. This new way of design greatly guarantees the processing parameters of the part is right and exclusive. The processing of complex novel bio-chip has been realized by this new function.
Qian, Linping; Wang, Zhen; Beletskiy, Evgeny V.; ...
2017-03-28
Here, the ability of Au catalysts to effect the challenging task of utilizing molecular oxygen for the selective epoxidation of cyclooctene is fascinating. Although supported nanometre-size Au particles are poorly active, here we show that solubilized atomic Au clusters, present in ng ml –1 concentrations and stabilized by ligands derived from the oxidized hydrocarbon products, are active. They can be formed from various Au sources. They generate initiators and propagators to trigger the onset of the auto-oxidation reaction with an apparent turnover frequency of 440 s –1, and continue to generate additional initiators throughout the auto-oxidation cycle without direct participationmore » in the cycle. Spectroscopic characterization suggests that 7–8 atom clusters are effective catalytically. Extension of work based on these understandings leads to the demonstration that these Au clusters are also effective in selective oxidation of cyclohexene, and that solubilized Pt clusters are also capable of generating initiators for cyclooctene epoxidation.« less
Bone Replacement Materials and Techniques Used for Achieving Vertical Alveolar Bone Augmentation
Sheikh, Zeeshan; Sima, Corneliu; Glogauer, Michael
2015-01-01
Alveolar bone augmentation in vertical dimension remains the holy grail of periodontal tissue engineering. Successful dental implant placement for restoration of edentulous sites depends on the quality and quantity of alveolar bone available in all spatial dimensions. There are several surgical techniques used alone or in combination with natural or synthetic graft materials to achieve vertical alveolar bone augmentation. While continuously improving surgical techniques combined with the use of auto- or allografts provide the most predictable clinical outcomes, their success often depends on the status of recipient tissues. The morbidity associated with donor sites for auto-grafts makes these techniques less appealing to both patients and clinicians. New developments in material sciences offer a range of synthetic replacements for natural grafts to address the shortcoming of a second surgical site and relatively high resorption rates. This narrative review focuses on existing techniques, natural tissues and synthetic biomaterials commonly used to achieve vertical bone height gain in order to successfully restore edentulous ridges with implant-supported prostheses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qian, Linping; Wang, Zhen; Beletskiy, Evgeny V.
Here, the ability of Au catalysts to effect the challenging task of utilizing molecular oxygen for the selective epoxidation of cyclooctene is fascinating. Although supported nanometre-size Au particles are poorly active, here we show that solubilized atomic Au clusters, present in ng ml –1 concentrations and stabilized by ligands derived from the oxidized hydrocarbon products, are active. They can be formed from various Au sources. They generate initiators and propagators to trigger the onset of the auto-oxidation reaction with an apparent turnover frequency of 440 s –1, and continue to generate additional initiators throughout the auto-oxidation cycle without direct participationmore » in the cycle. Spectroscopic characterization suggests that 7–8 atom clusters are effective catalytically. Extension of work based on these understandings leads to the demonstration that these Au clusters are also effective in selective oxidation of cyclohexene, and that solubilized Pt clusters are also capable of generating initiators for cyclooctene epoxidation.« less
Trends in auto emissions and gasoline composition.
Sawyer, R F
1993-01-01
The invention of the spark-ignited internal combustion engine provided a market for a petroleum middle distillate, gasoline, about 100 years ago. The internal combustion engine and gasoline have co-evolved until motor vehicles now annually consume about 110 billion gallons of gasoline in the United States. Continuing air pollution problems and resulting regulatory pressures are driving the need for further automotive emissions reductions. Engine and emissions control technology provided most earlier reductions. Changing the composition of gasoline will play a major role in the next round of reductions. The engineering and regulatory definition of a reformulated gasoline is proceeding rapidly, largely as the result of an auto and oil industry cooperative data generation program. It is likely that this new, reformulated gasoline will be introduced in high-ozone regions of the United States in the mid-1990s. Alternative clean fuels, primarily methane, methanol, and liquid petroleum gas, will become more widely used during this same period, probably first in fleet operations. PMID:7517353
NASA Astrophysics Data System (ADS)
Liu, Zhiyuan; Meng, Qiang
2014-05-01
This paper focuses on modelling the network flow equilibrium problem on a multimodal transport network with bus-based park-and-ride (P&R) system and congestion pricing charges. The multimodal network has three travel modes: auto mode, transit mode and P&R mode. A continuously distributed value-of-time is assumed to convert toll charges and transit fares to time unit, and the users' route choice behaviour is assumed to follow the probit-based stochastic user equilibrium principle with elastic demand. These two assumptions have caused randomness to the users' generalised travel times on the multimodal network. A comprehensive network framework is first defined for the flow equilibrium problem with consideration of interactions between auto flows and transit (bus) flows. Then, a fixed-point model with unique solution is proposed for the equilibrium flows, which can be solved by a convergent cost averaging method. Finally, the proposed methodology is tested by a network example.
[Auto-immune disorders as a possible cause of neuropsychiatric syndromes].
Martinez-Martinez, P; Molenaar, P C; Losen, M; Hoffmann, C; Stevens, J; de Witte, L D; van Amelsvoort, T; van Os, J; Rutten, B P F
2015-01-01
Changes that occur in the behaviour of voltage-gated ion channels and ligand-gated receptor channels due to gene mutations or auto-immune attack are the cause of channelopathies in the central and peripheral nervous system. Although the relation between molecular channel defects and clinical symptoms has been explained in the case of many neuromuscular channelopathies, the pathophysiology of auto-immunity in neuropsychiatric syndromes is still unclear. To review recent findings regarding neuronal auto-immune reactions in severe neuropsychiatric syndromes. Using PubMed, we consulted the literature published between 1990 and August 2014 relating to the occurrence of auto-immune antibodies in severe and persistent neuropsychiatric syndromes. Auto-antibodies have only limited access to the central nervous system, but if they do enter the system they can, in some cases, cause disease. We discuss recent findings regarding the occurrence of auto-antibodies against ligand-activated receptor channels and potassium channels in neuropsychiatric and neurological syndromes, including schizophrenia and limbic encephalitis. Although the occurrence of several auto-antibodies in schizophrenia has been confirmed, there is still no proof of a causal relationship in the syndrome. We still have no evidence of the prevalence of auto-immunity in neuropsychiatric syndromes. The discovery that an antibody against an ion channel is associated with some neuropsychiatric disorders may mean that in future it will be possible to treat patients by means of immunosuppression, which could lead to an improvement in a patient's cognitive abilities.
Kamal, Izdihar; Chelliah, Kanaga K; Mustafa, Nawal
2015-05-01
The aim of this research was to examine the average glandular dose (AGD) of radiation among different breast compositions of glandular and adipose tissue with auto-modes of exposure factor selection in digital breast tomosynthesis. This experimental study was carried out in the National Cancer Society, Kuala Lumpur, Malaysia, between February 2012 and February 2013 using a tomosynthesis digital mammography X-ray machine. The entrance surface air kerma and the half-value layer were determined using a 100H thermoluminescent dosimeter on 50% glandular and 50% adipose tissue (50/50) and 20% glandular and 80% adipose tissue (20/80) commercially available breast phantoms (Computerized Imaging Reference Systems, Inc., Norfolk, Virginia, USA) with auto-time, auto-filter and auto-kilovolt modes. The lowest AGD for the 20/80 phantom with auto-time was 2.28 milliGray (mGy) for two dimension (2D) and 2.48 mGy for three dimensional (3D) images. The lowest AGD for the 50/50 phantom with auto-time was 0.97 mGy for 2D and 1.0 mGy for 3D. The AGD values for both phantoms were lower against a high kilovolt peak and the use of auto-filter mode was more practical for quick acquisition while limiting the probability of operator error.
Mokarizadeh, Aram; Delirezh, Nowruz; Morshedi, Ahhmad; Mosayebi, Ghasem; Farshid, Amir-Abbas; Dalir-Naghadeh, Bahram
2012-01-01
Auto-reactive cells-mediated immune responses are responsible for the current tissue damages during autoimmunity. Accordingly, functional modulation of auto-reactive cells has been a pivotal aim in many of recent studies. In the current study, we investigated the possibility for insertion of regulatory molecules onto auto-reactive cells through exosomal nano-shuttles as a novel approach for phenotype modification of auto-reactive cells. The exosomes were isolated from supernatant of mesenchymal stem cells culture. Resultant exosomes co-cultured with lymphocytes were harvested from established EAE mice in the presence of antigenic MOG35-55 peptide. After 24 hr, insertion of exosomal tolerogenic molecules (PD-L1, TGF-β, galectin-1) onto auto-reactive cells were explored through flow cytometry. The potency of exosomal inserted membrane molecules to modulate phenotype of auto-reactive lymphocytes was assessed upon ELISA test for their-derived cytokines IFN-γ and IL-17. Incorporation of exosomal molecules into lymohocytes' membrane was confirmed by flow cytometric analyses for surface levels of mentioned molecules. Additionally, the decreased secretion of IFN-γ and IL-17 were detected in exosome pre-treated lymphocytes upon stimulation with MOG peptide. Mesenchymal stem cells -derived exosomes showed to be efficient organelles for insertion of bioactive tolerogenic molecules onto auto-reactive cells and modulation of their phenotypes.
Downtown Crossing: Auto Restricted Zone in Boston
DOT National Transportation Integrated Search
1982-07-01
The Downtown Crossing auto restricted zone, implemented in 1978, involved the : elimination of all auto traffic froma zone of twelve blocks encompassing six : different streets in Bostn's central business district. Some of the blocks were : pedestria...
; color:#5A5655; background-color:#F8F8F8; height:368px; text-align:left; overflow:auto; z-index:88 { display:block; position: relative; clear:right; margin: 3px 0 0 0; border: 1px solid #CCC; padding: 0; color : #5A5655; background-color: #F8F8F8; height:40px; width:723px; /*float:right;*/ text-align:left
Folinic acid treatment for schizophrenia associated with folate receptor autoantibodies.
Ramaekers, V T; Thöny, B; Sequeira, J M; Ansseau, M; Philippe, P; Boemer, F; Bours, V; Quadros, E V
2014-12-01
Auto-antibodies against folate receptor alpha (FRα) at the choroid plexus that block N(5)-methyltetrahydrofolate (MTHF) transfer to the brain were identified in catatonic schizophrenia. Acoustic hallucinations disappeared following folinic acid treatment. Folate transport to the CNS prevents homocysteine accumulation and delivers one-carbon units for methyl-transfer reactions and synthesis of purines. The guanosine derivative tetrahydrobiopterin acts as common co-factor for the enzymes producing dopamine, serotonin and nitric oxide. Our study selected patients with schizophrenia unresponsive to conventional treatment. Serum from these patients with normal plasma homocysteine, folate and vitamin B12 was tested for FR autoantibodies of the blocking type on serial samples each week. Spinal fluid was analyzed for MTHF and the metabolites of pterins, dopamine and serotonin. The clinical response to folinic acid treatment was evaluated. Fifteen of 18 patients (83.3%) had positive serum FR auto-antibodies compared to only 1 in 30 controls (3.3%) (χ(2)=21.6; p<0.0001). FRα antibody titers in patients fluctuated over time varying between negative and high titers, modulating folate flux to the CNS, which explained low CSF folate values in 6 and normal values in 7 patients. The mean±SD for CSF MTHF was diminished compared to previously established controls (t-test: 3.90; p=0.0002). A positive linear correlation existed between CSF MTHF and biopterin levels. CSF dopamine and serotonin metabolites were low or in the lower normal range. Administration of folinic acid (0.3-1mg/kg/day) to 7 participating patients during at least six months resulted in clinical improvement. Assessment of FR auto-antibodies in serum is recommended for schizophrenic patients. Clinical negative or positive symptoms are speculated to be influenced by the level and evolution of FRα antibody titers which determine folate flux to the brain with up- or down-regulation of brain folate intermediates linked to metabolic processes affecting homocysteine levels, synthesis of tetrahydrobiopterin and neurotransmitters. Folinic acid intervention appears to stabilize the disease process. Copyright © 2014 Elsevier Inc. All rights reserved.
Auto-Regulatory RNA Editing Fine-Tunes mRNA Re-Coding and Complex Behaviour in Drosophila
Savva, Yiannis A.; Jepson, James E.C; Sahin, Asli; Sugden, Arthur U.; Dorsky, Jacquelyn S.; Alpert, Lauren; Lawrence, Charles; Reenan, Robert A.
2014-01-01
Auto-regulatory feedback loops are a common molecular strategy used to optimize protein function. In Drosophila many mRNAs involved in neuro-transmission are re-coded at the RNA level by the RNA editing enzyme dADAR, leading to the incorporation of amino acids that are not directly encoded by the genome. dADAR also re-codes its own transcript, but the consequences of this auto-regulation in vivo are unclear. Here we show that hard-wiring or abolishing endogenous dADAR auto-regulation dramatically remodels the landscape of re-coding events in a site-specific manner. These molecular phenotypes correlate with altered localization of dADAR within the nuclear compartment. Furthermore, auto-editing exhibits sexually dimorphic patterns of spatial regulation and can be modified by abiotic environmental factors. Finally, we demonstrate that modifying dAdar auto-editing affects adaptive complex behaviors. Our results reveal the in vivo relevance of auto-regulatory control over post-transcriptional mRNA re-coding events in fine-tuning brain function and organismal behavior. PMID:22531175
Intrinsic Tau Acetylation Is Coupled to Auto-Proteolytic Tau Fragmentation
Cohen, Todd J.; Constance, Brian H.; Hwang, Andrew W.; James, Michael; Yuan, Chao-Xing
2016-01-01
Tau proteins are abnormally aggregated in a range of neurodegenerative tauopathies including Alzheimer’s disease (AD). Recently, tau has emerged as an extensively post-translationally modified protein, among which lysine acetylation is critical for normal tau function and its pathological aggregation. Here, we demonstrate that tau isoforms have different propensities to undergo lysine acetylation, with auto-acetylation occurring more prominently within the lysine-rich microtubule-binding repeats. Unexpectedly, we identified a unique intrinsic property of tau in which auto-acetylation induces proteolytic tau cleavage, thereby generating distinct N- and C-terminal tau fragments. Supporting a catalytic reaction-based mechanism, mapping and mutagenesis studies showed that tau cysteines, which are required for acetyl group transfer, are also essential for auto-proteolytic tau processing. Further mass spectrometry analysis identified the C-terminal 2nd and 4th microtubule binding repeats as potential sites of auto-cleavage. The identification of acetylation-mediated auto-proteolysis provides a new biochemical mechanism for tau self-regulation and warrants further investigation into whether auto-catalytic functions of tau are implicated in AD and other tauopathies. PMID:27383765
Auto-phosphorylation Represses Protein Kinase R Activity.
Wang, Die; de Weerd, Nicole A; Willard, Belinda; Polekhina, Galina; Williams, Bryan R G; Sadler, Anthony J
2017-03-10
The central role of protein kinases in controlling disease processes has spurred efforts to develop pharmaceutical regulators of their activity. A rational strategy to achieve this end is to determine intrinsic auto-regulatory processes, then selectively target these different states of kinases to repress their activation. Here we investigate auto-regulation of the innate immune effector protein kinase R, which phosphorylates the eukaryotic initiation factor 2α to inhibit global protein translation. We demonstrate that protein kinase R activity is controlled by auto-inhibition via an intra-molecular interaction. Part of this mechanism of control had previously been reported, but was then controverted. We account for the discrepancy and extend our understanding of the auto-inhibitory mechanism by identifying that auto-inhibition is paradoxically instigated by incipient auto-phosphorylation. Phosphor-residues at the amino-terminus instigate an intra-molecular interaction that enlists both of the N-terminal RNA-binding motifs of the protein with separate surfaces of the C-terminal kinase domain, to co-operatively inhibit kinase activation. These findings identify an innovative mechanism to control kinase activity, providing insight for strategies to better regulate kinase activity.
Intrinsic Tau Acetylation Is Coupled to Auto-Proteolytic Tau Fragmentation.
Cohen, Todd J; Constance, Brian H; Hwang, Andrew W; James, Michael; Yuan, Chao-Xing
2016-01-01
Tau proteins are abnormally aggregated in a range of neurodegenerative tauopathies including Alzheimer's disease (AD). Recently, tau has emerged as an extensively post-translationally modified protein, among which lysine acetylation is critical for normal tau function and its pathological aggregation. Here, we demonstrate that tau isoforms have different propensities to undergo lysine acetylation, with auto-acetylation occurring more prominently within the lysine-rich microtubule-binding repeats. Unexpectedly, we identified a unique intrinsic property of tau in which auto-acetylation induces proteolytic tau cleavage, thereby generating distinct N- and C-terminal tau fragments. Supporting a catalytic reaction-based mechanism, mapping and mutagenesis studies showed that tau cysteines, which are required for acetyl group transfer, are also essential for auto-proteolytic tau processing. Further mass spectrometry analysis identified the C-terminal 2nd and 4th microtubule binding repeats as potential sites of auto-cleavage. The identification of acetylation-mediated auto-proteolysis provides a new biochemical mechanism for tau self-regulation and warrants further investigation into whether auto-catalytic functions of tau are implicated in AD and other tauopathies.
Auto-fusion and the shaping of neurons and tubes
Soulavie, Fabien; Sundaram, Meera V.
2016-01-01
Cells adopt specific shapes that are necessary for specific functions. For example, some neurons extend elaborate arborized dendrites that can contact multiple targets. Epithelial and endothelial cells can form tiny seamless unicellular tubes with an intracellular lumen. Recent advances showed that cells can auto-fuse to acquire those specific shapes. During auto-fusion, a cell merges two parts of its own plasma membrane. In contrast to cell-cell fusion or macropinocytic fission, which result in the merging or formation of two separate membrane bound compartments, auto-fusion preserves one compartment, but changes its shape. The discovery of auto-fusion in C. elegans was enabled by identification of specific protein fusogens, EFF-1 and AFF-1, that mediate cell-cell fusion. Phenotypic characterization of eff-1 and aff-1 mutants revealed that fusogen-mediated fusion of two parts of the same cell can be used to sculpt dendritic arbors, reconnect two parts of an axon after injury, or form a hollow unicellular tube. Similar auto-fusion events recently were detected in vertebrate cells, suggesting that auto-fusion could be a widely used mechanism for shaping neurons and tubes. PMID:27436685
Kouabosso, André; Mossoro-Kpinde, Christian Diamant; Bouassa, Ralph-Sydney Mboumba; Longo, Jean De Dieu; Mbeko Simaleko, Marcel; Grésenguet, Gérard; Bélec, Laurent
2018-04-01
The accuracy of CD4 T cell monitoring by the recently developed flow cytometry-based CD4 T cell counting Muse™ Auto CD4/CD4% Assay analyzer (EMD Millipore Corporation, Merck Life Sciences, KGaA, Darmstadt, Germany) was evaluated in trained lay providers against laboratory technicians. After 2 days of training on the Muse™ Auto CD4/CD4% analyzer, EDTA-blood samples from 6 HIV-positive and 4 HIV-negative individuals were used for CD4 T cell counting in triplicate in parallel by 12 trained lay providers as compared to 10 lab technicians. Mean number of CD4 T cells in absolute number was 829 ± 380 cells/μl by lay providers and 794 ± 409 cells/μl by technicians (P > 0.05); and in percentage 36.2 ± 14.8%CD4 by lay providers and 36.1 ± 15.0%CD4 by laboratory technician (P > 0.05). The unweighted linear regression and Passing-Bablok regression analyses on CD4 T cell results expressed in absolute count revealed moderate correlation between CD4 T cell counts obtained by lay providers and lab technicians. The mean absolute bias measured by Bland-Altman analysis between CD4 T cell/μl obtained by lay providers and lab technicians was -3.41 cells/μl. Intra-assay coefficient of variance (CV) of Muse™ Auto CD4/CD4% in absolute number was 10.1% by lay providers and 8.5% by lab technicians (P > 0.05), and in percentage 5.5% by lay providers and 4.4% by lab technicians (P > 0.05). The inter-assay CV of Muse™ Auto CD4/CD4% in absolute number was 13.4% by lay providers and 10.3% by lab technicians (P > 0.05), and in percentage 7.8% by lay providers and 6.9% by lab technicians (P > 0.05). The study demonstrates the feasibility of CD4 T cell counting using the alternative flow cytometer Muse™ Auto CD4/CD4% analyzer by trained lay providers and therefore the practical possibility of decentralization CD4 T cell counting to health community centers. Copyright © 2018. Published by Elsevier B.V.
The Implementation of Downtown Auto-Restricted Projects
DOT National Transportation Integrated Search
1984-06-01
In 1975 UMTA's Office of Service and Methods Demonstration launched a demonstration program of Auto Restricted Zones (ARZs) which went beyond the traditional scope of linear pedestrian malls. ARZs involve auto restriction in a large geographic area w...
Tiberkevich, Vasil S.; Khymyn, Roman S.; Tang, Hong X.; Slavin, Andrei N.
2014-01-01
For auto-oscillators of different nature (e.g. active cells in a human heart under the action of a pacemaker, neurons in brain, spin-torque nano-oscillators, micro and nano-mechanical oscillators, or generating Josephson junctions) a critically important property is their ability to synchronize with each other. The synchronization properties of an auto oscillator are directly related to its sensitivity to external signals. Here we demonstrate that a non-isochronous (having generation frequency dependent on the amplitude) auto-oscillator with delayed feedback can have an extremely high sensitivity to external signals and unusually large width of the phase-locking band near the boundary of the stable auto-oscillation regime. This property could be used for the development of synchronized arrays of non-isochronous auto-oscillators in physics and engineering, and, for instance, might bring a better fundamental understanding of ways to control a heart arrythmia in medicine. PMID:24464086
AutoLock: a semiautomated system for radiotherapy treatment plan quality control
Lowe, Matthew; Hardy, Mark J.; Boylan, Christopher J.; Whitehurst, Philip; Rowbottom, Carl G.
2015-01-01
A semiautomated system for radiotherapy treatment plan quality control (QC), named AutoLock, is presented. AutoLock is designed to augment treatment plan QC by automatically checking aspects of treatment plans that are well suited to computational evaluation, whilst summarizing more subjective aspects in the form of a checklist. The treatment plan must pass all automated checks and all checklist items must be acknowledged by the planner as correct before the plan is finalized. Thus AutoLock uniquely integrates automated treatment plan QC, an electronic checklist, and plan finalization. In addition to reducing the potential for the propagation of errors, the integration of AutoLock into the plan finalization workflow has improved efficiency at our center. Detailed audit data are presented, demonstrating that the treatment plan QC rejection rate fell by around a third following the clinical introduction of AutoLock. PACS number: 87.55.Qr PMID:26103498
AutoLock: a semiautomated system for radiotherapy treatment plan quality control.
Dewhurst, Joseph M; Lowe, Matthew; Hardy, Mark J; Boylan, Christopher J; Whitehurst, Philip; Rowbottom, Carl G
2015-05-08
A semiautomated system for radiotherapy treatment plan quality control (QC), named AutoLock, is presented. AutoLock is designed to augment treatment plan QC by automatically checking aspects of treatment plans that are well suited to computational evaluation, whilst summarizing more subjective aspects in the form of a checklist. The treatment plan must pass all automated checks and all checklist items must be acknowledged by the planner as correct before the plan is finalized. Thus AutoLock uniquely integrates automated treatment plan QC, an electronic checklist, and plan finalization. In addition to reducing the potential for the propagation of errors, the integration of AutoLock into the plan finalization workflow has improved efficiency at our center. Detailed audit data are presented, demonstrating that the treatment plan QC rejection rate fell by around a third following the clinical introduction of AutoLock.
NASA Astrophysics Data System (ADS)
Saijyo, Katsuya; Nishiwaki, Kazuie; Yoshihara, Yoshinobu
The CFD simulations were performed integrating the low-temperature oxidation reaction. Analyses were made with respect to the first auto-ignition location in the case of a premixed-charge compression auto-ignition in a laminar flow field and in the case of the auto-ignition in an end gas during an S. I. Engine combustion process. In the latter simulation, the spatially-filtered transport equations were solved to express fluctuating temperatures in a turbulent flow in consideration of strong non-linearity to temperature in the reaction equations. It is suggested that the first auto-ignition location does not always occur at higher-temperature locations and that the difference in the locations of the first auto-ignition depends on the time period during which the local end gas temperature passes through the region of shorter ignition delay, including the NTC region.
Influence of tooth profile on the noncircular gear tooth contact
NASA Astrophysics Data System (ADS)
Cristescu, A.; Andrei, L.; Cristescu, B.
2017-02-01
With noncircular gears, the continuous modification of the tooth meshing, in terms of variation of the tooth profiles and the line of action position and inclination, makes difficult the implementation of a general standard procedure for the analysis of the noncircular gears tooth contact. In this paper, the authors present a graphical approach that enables the tooth contact static pattern to be produced and evaluated in case of a noncircular gear with complex geometry of the pitch curve. The study is virtually developed, in AutoCAD environment, by animating and investigating the gear solid models in mesh. The tooth static contact analysis enables the path of contact area and distribution to be evaluated in correlation with the following variable initial data: gear pitch curve geometry, tooth profile geometry, as a consequence of different generating procedures, and the gear pressure angle. It was found out that the noncircular gear tooth contact could be improved by choosing different procedures for the tooth flank generation in concave and convex zones and by increasing the gear pressure angle.
Operant Conditioning in Honey Bees (Apis mellifera L.): The Cap Pushing Response.
Abramson, Charles I; Dinges, Christopher W; Wells, Harrington
2016-01-01
The honey bee has been an important model organism for studying learning and memory. More recently, the honey bee has become a valuable model to understand perception and cognition. However, the techniques used to explore psychological phenomena in honey bees have been limited to only a few primary methodologies such as the proboscis extension reflex, sting extension reflex, and free flying target discrimination-tasks. Methods to explore operant conditioning in bees and other invertebrates are not as varied as with vertebrates. This may be due to the availability of a suitable response requirement. In this manuscript we offer a new method to explore operant conditioning in honey bees: the cap pushing response (CPR). We used the CPR to test for difference in learning curves between novel auto-shaping and more traditional explicit-shaping. The CPR protocol requires bees to exhibit a novel behavior by pushing a cap to uncover a food source. Using the CPR protocol we tested the effects of both explicit-shaping and auto-shaping techniques on operant conditioning. The goodness of fit and lack of fit of these data to the Rescorla-Wagner learning-curve model, widely used in classical conditioning studies, was tested. The model fit well to both control and explicit-shaping results, but only for a limited number of trials. Learning ceased rather than continuing to asymptotically approach the physiological most accurate possible. Rate of learning differed between shaped and control bee treatments. Learning rate was about 3 times faster for shaped bees, but for all measures of proficiency control and shaped bees reached the same level. Auto-shaped bees showed one-trial learning rather than the asymptotic approach to a maximal efficiency. However, in terms of return-time, the auto-shaped bees' learning did not carry over to the covered-well test treatments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Joyce Jihyun; Schetrit, Oren; Yin, Rongxin
Demand response (DR) – allowing customers to respond to reliability requests and market prices by changing electricity use from their normal consumption pattern – continues to be seen as an attractive means of demand-side management and a fundamental smart-grid improvement that links supply and demand. From October 2011 to December 2013, the Demand Response Research Center at Lawrence Berkeley National Laboratory, the New York State Energy Research and Development Authority, and partners Honeywell and Akuacom, have conducted a demonstration project enabling Automated Demand Response (Auto-DR) in large commercial buildings located in New York City using Open Automated Demand Response (OpenADR)more » communication protocols. In particular, this project focuses on demonstrating how the OpenADR platform, enabled by Akuacom, can automate and simplify interactions between buildings and various stakeholders in New York State and enable the automation of customers’ price response to yield bill savings under dynamic pricing. In this paper, the cost control opportunities under day-ahead hourly pricing and Auto-DR control strategies are presented for four demonstration buildings; present the breakdown of Auto-DR enablement costs; summarize the field test results and their load impact; and show potential bill savings by enabling automated price response under Consolidated Edison’s Mandatory Hourly Pricing (MHP) tariff. For one of the sites, the potential bill savings at the site’s current retail rate are shown. Facility managers were given granular equipment-level opt-out capability to ensure full control of the sites during the Auto-DR implementation. The expected bill savings ranged from 1.1% to 8.0% of the total MHP bill. The automation and enablement costs ranged from $70 to $725 per kW shed. The results show that OpenADR can facilitate the automation of price response, deliver savings to the customers and opt-out capability of the implementation retains control of the sites by facility managers.« less
Zhong, Zhuangmin; Sha, Qing'e; Zheng, Junyu; Yuan, Zibing; Gao, Zongjiang; Ou, Jiamin; Zheng, Zhuoyun; Li, Cheng; Huang, Zhijiong
2017-04-01
Accurate depiction of VOCs emission characteristics is essential for the formulation of VOCs control strategies. As one of the continuous efforts in improving VOCs emission characterization in the Pearl River Delta (PRD) region, this study targeted on surface coating industry, the most important VOCs emission sources in the PRD. Sectors in analysis included shipbuilding coating, wood furniture coating, metal surface coating, plastic surface coating, automobile coating and fabric surface coating. Sector-based field measurement was conducted to characterize VOCs emission factors and source profiles in the PRD. It was found that the raw material-based VOCs emission factors for these six sectors ranged from 0.34 to 0.58kg VOCs per kg of raw materials (kg·kg -1 ) while the emission factors based on the production yield varied from 0.59kg to 13.72t VOCs for each production manufactured. VOCs emission factors of surface coating industry were therefore preferably calculated based on raw materials with low uncertainties. Source profiles differed greatly among different sectors. Aromatic was the largest group for shipbuilding coating, wood furniture coating, metal surface coating and automobile coating while the oxygenated VOCs (OVOCs) were the most abundant in the plastic and fabric surface coating sectors. The major species of aromatic VOCs in each of these six sectors were similar, mainly toluene and m/p-xylene, while the OVOCs varied among the different sectors. VOCs profiles in the three processes of auto industry, i.e., auto coating, auto drying and auto repairing, also showed large variations. The major species in these sectors in the PRD were similar with other places but the proportions of individual compounds were different. Some special components were also detected in the PRD region. This study highlighted the importance of updating local source profiles in a comprehensive and timely manner. Copyright © 2016 Elsevier B.V. All rights reserved.
Operant Conditioning in Honey Bees (Apis mellifera L.): The Cap Pushing Response
Abramson, Charles I.; Dinges, Christopher W.; Wells, Harrington
2016-01-01
The honey bee has been an important model organism for studying learning and memory. More recently, the honey bee has become a valuable model to understand perception and cognition. However, the techniques used to explore psychological phenomena in honey bees have been limited to only a few primary methodologies such as the proboscis extension reflex, sting extension reflex, and free flying target discrimination-tasks. Methods to explore operant conditioning in bees and other invertebrates are not as varied as with vertebrates. This may be due to the availability of a suitable response requirement. In this manuscript we offer a new method to explore operant conditioning in honey bees: the cap pushing response (CPR). We used the CPR to test for difference in learning curves between novel auto-shaping and more traditional explicit-shaping. The CPR protocol requires bees to exhibit a novel behavior by pushing a cap to uncover a food source. Using the CPR protocol we tested the effects of both explicit-shaping and auto-shaping techniques on operant conditioning. The goodness of fit and lack of fit of these data to the Rescorla-Wagner learning-curve model, widely used in classical conditioning studies, was tested. The model fit well to both control and explicit-shaping results, but only for a limited number of trials. Learning ceased rather than continuing to asymptotically approach the physiological most accurate possible. Rate of learning differed between shaped and control bee treatments. Learning rate was about 3 times faster for shaped bees, but for all measures of proficiency control and shaped bees reached the same level. Auto-shaped bees showed one-trial learning rather than the asymptotic approach to a maximal efficiency. However, in terms of return-time, the auto-shaped bees’ learning did not carry over to the covered-well test treatments. PMID:27626797
NASA Astrophysics Data System (ADS)
Taylor, D. G.; Rost, S.; Houseman, G.
2015-12-01
In recent years the technique of cross-correlating the ambient seismic noise wavefield at two seismometers to reconstruct empirical Green's Functions for the determination of Earth structure has been a powerful tool to study the Earth's interior without earthquake or man-made sources. However, far less attention has been paid to using auto-correlations of seismic noise to reveal body wave reflections from interfaces in the subsurface. In principle, the Green's functions thus derived should be comparable to the Earth's impulse response to a co-located source and receiver. We use data from a dense seismic array (Dense Array for Northern Anatolia - DANA) deployed across the northern branch of the North Anatolian Fault Zone (NAFZ) in the region of the 1999 magnitude 7.6 Izmit earthquake in western Turkey. The NAFZ is a major strike-slip system that extends ~1200 km across northern Turkey and continues to pose a high level of seismic hazard, in particular to the mega-city of Istanbul. We construct reflection images for the entire crust and upper mantle over the ~35 km by 70 km footprint of the 70-station DANA array. Using auto-correlations of vertical and horizontal components of ground motion, both P- and S-wave velocity information can be retrieved from the wavefield to constrain crustal structure further to established methods. We show that clear P-wave reflections from the crust-mantle boundary (Moho) can be retrieved using the autocorrelation technique, indicating topography on the Moho on horizontal scales of less than 10 km. Offsets in crustal structure can be identified that seem to be correlated with the surface expression of the fault zone in the region. The combined analysis of auto-correlations using vertical and horizontal components will lead to further insight into the fault zone structure throughout the crust and upper mantle.
Stasche, Norbert
2006-01-01
Positive airway pressure (PAP) is the therapy of choice for most sleep-related breathing disorders (SRBD). A variety of PAP devices using positive airway pressure (CPAP, BiPAP, APAP, ASV) must be carefully considered before application. This overview aims to provide criteria for choosing the optimal PAP device according to severity and type of sleep-related breathing disorder. In addition, the range of therapeutic applications, constraints and side effects as well as alternative methods to PAP will be discussed. This review is based on an analysis of current literature and clinical experience. The data is presented from an ENT-sleep-laboratory perspective and is designed to help the ENT practitioner initiate treatment and provide support. Different titration methods, current devices and possible applications will be described. In addition to constant pressure devices (CPAP), most commonly used for symptomatic obstructive sleep apnoea (OSA) without complicating conditions, BiPAP models will be introduced. These allow two different positive pressure settings and are thus especially suitable for patients with cardiopulmonary diseases or patients with pressure intolerance, increasing compliance in this subgroup considerably. Compliance can also be increased in patients during first night of therapy, patients with highly variable pressure demands or position-dependent OSA, by using self-regulating Auto-adjust PAP devices (Automatic positive airway pressure, APAP). Patients with Cheyne-Stokes breathing, a subtype of central sleep apnoea, benefit from adaptive servo-ventilation (ASV), which analyzes breathing patterns continually and adjusts the actual ventilation pressure accordingly. This not only reduces daytime sleepiness, but can also influence heart disease positively. Therapy with positive airway pressure is very effective in eliminating obstruction-related sleep diseases and symptoms. However, because therapy is generally applied for life, the optimal PAP device must be carefully selected, taking into account side effects that influence compliance. PMID:22073075
NASA Technical Reports Server (NTRS)
Gladden, Roy E.; Khanampornpan, Teerapat; Fisher, Forest W.
2010-01-01
Version 5.0 of the AutoGen software has been released. Previous versions, variously denoted Autogen and autogen, were reported in two articles: Automated Sequence Generation Process and Software (NPO-30746), Software Tech Briefs (Special Supplement to NASA Tech Briefs), September 2007, page 30, and Autogen Version 2.0 (NPO- 41501), NASA Tech Briefs, Vol. 31, No. 10 (October 2007), page 58. To recapitulate: AutoGen (now signifying automatic sequence generation ) automates the generation of sequences of commands in a standard format for uplink to spacecraft. AutoGen requires fewer workers than are needed for older manual sequence-generation processes, and greatly reduces sequence-generation times. The sequences are embodied in spacecraft activity sequence files (SASFs). AutoGen automates generation of SASFs by use of another previously reported program called APGEN. AutoGen encodes knowledge of different mission phases and of how the resultant commands must differ among the phases. AutoGen also provides means for customizing sequences through use of configuration files. The approach followed in developing AutoGen has involved encoding the behaviors of a system into a model and encoding algorithms for context-sensitive customizations of the modeled behaviors. This version of AutoGen addressed the MRO (Mars Reconnaissance Orbiter) primary science phase (PSP) mission phase. On previous Mars missions this phase has more commonly been referred to as mapping phase. This version addressed the unique aspects of sequencing orbital operations and specifically the mission specific adaptation of orbital operations for MRO. This version also includes capabilities for MRO s role in Mars relay support for UHF relay communications with the MER rovers and the Phoenix lander.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Group Auto Club Enterprise Insurance Group Auto-Owners Insurance Group Berkshire Hathaway/GEICO... Insurance Companies Metropolitan Life Auto & Home Group Mercury General Group Nationwide Group Progressive...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Group Auto Club Enterprise Insurance Group Auto-Owners Insurance Group Berkshire Hathaway/GEICO... Insurance Companies Metropolitan Life Auto & Home Group Mercury General Group Nationwide Group Progressive...
Bettinzoli, Michela; Taranto-Montemurro, Luigi; Messineo, Ludovico; Corda, Luciano; Redolfi, Stefania; Ferliga, Mauro; Tantucci, Claudio
2014-12-01
The purpose of this study was to compare the therapeutic pressure determined by an automated CPAP device (AutoCPAP) during the titration period, between nasal and oronasal mask and the residual apnea-hypopnea index (AHI) on a subsequent poligraphy performed with the established therapeutic CPAP. As a retrospective study, 109 subjects with moderate and severe obstructive sleep apnea-hypopnea (apnea-hypopnea index≥15 events/h) were studied. CPAP titration was performed using an auto-titrating device. There was significant difference in the mean pressure delivered with autoCPAP between the group of patients using the nasal mask (mean 10.0 cmH2O±2.0 SD) and the group which used the oronasal mask (mean 11.2 cmH2O±2.1) (p<0.05). Residual apneas were lower when using a nasal mask: average AHI of 2.6±2.5 compared to 4.5±4.0 using an oronasal mask (p<0.05). On multivariate analysis, the only independent predictor of the level of therapeutic pressure of CPAP was the type of mask used (r=0.245, p 0.008). Therapeutic CPAP level for OSAH is higher when administered via oronasal mask, leaving more residual events. These findings suggest that nasal mask should be the first choice for OSAH treatment.
Aran, Adi; Weiner, Karin; Lin, Ling; Finn, Laurel Ann; Greco, Mary Ann; Peppard, Paul; Young, Terry; Ofran, Yanay; Mignot, Emmanuel
2010-01-01
Post-streptococcal autoimmunity affects millions worldwide, targeting multiple organs including the heart, brain, and kidneys. To explore the post-streptococcal autoimmunity spectrum, we used western blot analyses, to screen 310 sera from healthy subjects with (33%) and without (67%) markers of recent streptococcal infections [anti-Streptolysin O (ASLO) or anti-DNAse B (ADB)]. A 58 KDa protein, reacting strongly with post-streptococcal sera, was identified as Protein Disulfide Isomerase (PDI), an abundant protein with pleiotropic metabolic, immunologic, and thrombotic effects. Anti-PDI autoantibodies, purified from human sera, targeted similar epitopes in Streptolysin O (SLO, P51-61) and PDI (P328-338). The correlation between post-streptococcal status and anti-human PDI auto-immunity was further confirmed in a total of 2987 samples (13.6% in 530 ASLO positive versus 5.6% in 2457 ASLO negative samples, p<0.0001). Finally, anti-PDI auto-antibodies inhibited PDI-mediated insulin degradation in vitro (n = 90, p<0.001), and correlated with higher serum insulin (14.1 iu/ml vs. 12.2 iu/ml, n = 1215, p = 0.039) and insulin resistance (Homeostatic Model Assessment (HOMA) 4.1 vs. 3.1, n = 1215, p = 0.004), in a population-based cohort. These results identify PDI as a major target of post-streptococcal autoimmunity, and establish a new link between infection, autoimmunity, and metabolic disturbances. PMID:20886095
Effect of Swirl on an Unstable Single-Element Gas-Gas Rocket Engine
2014-06-01
at 300 K, and the combustor is filled with a mixture of water and carbon dioxide at 1500 K. The warmer temperature in the combustor enables the auto...a variety of configurations including gas turbines and rocket engines.4–13 The single-element engine chosen for this study is the continuously...combustion systems including gas turbines , rocket engines, and industrial furnaces. Swirl can have dramatic effects on the flowfield; these include jet growth
Type of Mask May Impact on Continuous Positive Airway Pressure Adherence in Apneic Patients
Borel, Jean Christian; Tamisier, Renaud; Dias-Domingos, Sonia; Sapene, Marc; Martin, Francis; Stach, Bruno; Grillet, Yves; Muir, Jean François; Levy, Patrick; Series, Frederic; Pepin, Jean-Louis
2013-01-01
Rationale In obstructive sleep apnea patients (OSA), continuous positive airway pressure (CPAP) adherence is crucial to improve symptoms and cardiometabolic outcomes. The choice of mask may influence CPAP adherence but this issue has never been addressed properly. Objective To evaluate the impact of nasal pillows, nasal and oronasal masks on CPAP adherence in a cohort of OSA. Methods Newly CPAP treated OSA participating in “Observatoire Sommeil de la Fédération de Pneumologie”, a French national prospective cohort, were included between March 2009 and December 2011. Anthropometric data, medical history, OSA severity, sleepiness, depressive status, treatment modalities (auto-CPAP versus fixed pressure, pressure level, interface type, use of humidifiers) and CPAP-related side effects were included in multivariate analysis to determine independent variables associated with CPAP adherence. Results 2311 OSA (age = 57(12) years, apnea+hypopnea index = 41(21)/h, 29% female) were included. Nasal masks, oronasal masks and nasal pillows were used by 62.4, 26.2 and 11.4% of the patients, respectively. In univariate analysis, oronasal masks and nasal pillows were associated with higher risk of CPAP non-adherence. CPAP non-adherence was also associated with younger age, female gender, mild OSA, gastroesophageal reflux, depression status, low effective pressure and CPAP-related side effects. In multivariate analysis, CPAP non-adherence was associated with the use of oronasal masks (OR = 2.0; 95%CI = 1.6; 2.5), depression, low effective pressure, and side effects. Conclusion As oronasal masks negatively impact on CPAP adherence, a nasal mask should be preferred as the first option. Patients on oronasal masks should be carefully followed. PMID:23691209
[DNA Extraction from Old Bones by AutoMate Express™ System].
Li, B; Lü, Z
2017-08-01
To establish a method for extracting DNA from old bones by AutoMate Express™ system. Bones were grinded into powder by freeze-mill. After extraction by AutoMate Express™, DNA were amplified and genotyped by Identifiler®Plus and MinFiler™ kits. DNA were extracted from 10 old bone samples, which kept in different environments with the postmortem interval from 10 to 20 years, in 3 hours by AutoMate Express™ system. Complete STR typing results were obtained from 8 samples. AutoMate Express™ system can quickly and efficiently extract DNA from old bones, which can be applied in forensic practice. Copyright© by the Editorial Department of Journal of Forensic Medicine
Doppler, Kathrin; Appeltshauser, Luise; Krämer, Heidrun H; Ng, Judy King Man; Meinl, Edgar; Villmann, Carmen; Brophy, Peter; Dib-Hajj, Sulayman D; Waxman, Stephen G; Weishaupt, Andreas; Sommer, Claudia
2015-01-01
Multifocal motor neuropathy is an immune mediated disease presenting with multifocal muscle weakness and conduction block. IgM auto-antibodies against the ganglioside GM1 are detectable in about 50% of the patients. Auto-antibodies against the paranodal proteins contactin-1 and neurofascin-155 and the nodal protein neurofascin-186 have been detected in subgroups of patients with chronic inflammatory demyelinating polyneuropathy. Recently, auto-antibodies against neurofascin-186 and gliomedin were described in more than 60% of patients with multifocal motor neuropathy. In the current study, we aimed to validate this finding, using a combination of different assays for auto-antibody detection. In addition we intended to detect further auto-antibodies against paranodal proteins, specifically contactin-1 and neurofascin-155 in multifocal motor neuropathy patients' sera. We analyzed sera of 33 patients with well-characterized multifocal motor neuropathy for IgM or IgG anti-contactin-1, anti-neurofascin-155 or -186 antibodies using enzyme-linked immunosorbent assay, binding assays with transfected human embryonic kidney 293 cells and murine teased fibers. We did not detect any IgM or IgG auto-antibodies against contactin-1, neurofascin-155 or -186 in any of our multifocal motor neuropathy patients. We conclude that auto-antibodies against contactin-1, neurofascin-155 and -186 do not play a relevant role in the pathogenesis in this cohort with multifocal motor neuropathy.
Wang, Wei; Lim, Liangzhong; Baskaran, Yohendran; Manser, Ed; Song, Jianxing
2013-08-16
Six human PAK members are classified into groups I (PAKs 1-3) and II (PAK4-6). Previously, only group I PAKs were thought to be auto-inhibited but very recently PAK4, the prototype of group II PAKs, has also been shown to be auto-inhibited by its N-terminal regulatory domain. However, the complete auto-inhibitory domain (AID) sequence remains undefined and the mechanism underlying its auto-inhibition is largely elusive. Here, the N-terminal regulatory domain of PAK4 sufficient for auto-inhibiting and binding Cdc42/Rac was characterized to be intrinsically unstructured, but nevertheless we identified the entire AID sequence by NMR. Strikingly, an AID peptide was derived by deleting the binding-unnecessary residues, which has a Kd of 320 nM to the PAK4 catalytic domain. Consequently, the PAK4 crystal structure complexed with the entire AID has been determined, which reveals that the complete kinase cleft is occupied by 20 AID residuescomposed of an N-terminal α-helix and a previously-identified pseudosubstrate motif, thus achieving auto-inhibition. Our study reveals that PAK4 is auto-inhibited by a novel mechanism which is completely different from that for PAK1, thus bearing critical implications for design of inhibitors specific for group II PAKs. Copyright © 2013 Elsevier Inc. All rights reserved.
Adak, Prasenjit; Sahu, Ravi; Elumalai, Suresh Pandian
2016-02-15
Vehicular emission is one of the most important contributors of urban air pollution. To quantify the impact of traffic on urban air quality, it is necessary to quantify vehicular emission. In many cities of India, such as Dhanbad, shared auto-rickshaw is the pre-dominant mode of transportation. Indian Driving Cycle (IDC) and Modified Indian Driving Cycle (MIDC) are used for emission testing of motorcycles, shared auto-rickshaws and passenger cars in India for regulatory purposes. IDC used for motorcycles and shared auto-rickshaws does not recognize the difference in two vehicle classes in terms of driving pattern. In real world, shared auto-rickshaws, behave differently than motorcycles. To quantify the impact of shared auto-rickshaws on urban air quality accurately, emission factors (EFs) are required to derive from real-world driving cycles (DCs). In heterogeneous traffic, vehicles of one class affect the behavior of vehicles of other classes. To estimate the emissions from different vehicle classes accurately, EFs for motorcycles and passenger cars are also required to be revised. In this study, real-world DCs were developed for motorcycles, shared auto-rickshaws and passenger cars in Dhanbad. Developed DCs were used to calculate EFs for respective classes. Shared auto-rickshaws were found to have the highest deviation from EFs derived using IDC. Copyright © 2015 Elsevier B.V. All rights reserved.
Control-based continuation: Bifurcation and stability analysis for physical experiments
NASA Astrophysics Data System (ADS)
Barton, David A. W.
2017-02-01
Control-based continuation is technique for tracking the solutions and bifurcations of nonlinear experiments. The idea is to apply the method of numerical continuation to a feedback-controlled physical experiment such that the control becomes non-invasive. Since in an experiment it is not (generally) possible to set the state of the system directly, the control target becomes a proxy for the state. Control-based continuation enables the systematic investigation of the bifurcation structure of a physical system, much like if it was numerical model. However, stability information (and hence bifurcation detection and classification) is not readily available due to the presence of stabilising feedback control. This paper uses a periodic auto-regressive model with exogenous inputs (ARX) to approximate the time-varying linearisation of the experiment around a particular periodic orbit, thus providing the missing stability information. This method is demonstrated using a physical nonlinear tuned mass damper.
SU-F-J-156: The Feasibility of MR-Only IMRT Planning for Prostate Anatomy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vaitheeswaran, R; Sivaramakrishnan, KR; Kumar, Prashant
Purpose: For prostate anatomy, previous investigations have shown that simulated CT (sCT) generated from MR images can be used for accurate dose computation. In this study, we demonstrate the feasibility of MR-only IMRT planning for prostate case. Methods: Regular CT (rCT) and MR images of the same patient were acquired for prostate anatomy. Regions-of-interest (ROIs) i.e. target and risk structures are delineated on the rCT. A simulated CT (sCT) is generated from the MR image using the method described by Schadewaldt N et al. Their work establishes the clinical acceptability of dose calculation results on the sCT when compared tomore » rCT. rCT and sCT are rigidly registered to ensure proper alignment between the two images. rCT and sCT are overlaid on each other and slice-wise visual inspection confirms excellent agreement between the two images. ROIs on the rCT are copied over to sCT. Philips AutoPlanning solution is used for generating treatment plans. The same treatment technique protocol (plan parameters and clinical goals) is used to generate AutoPlan-rCT and AutoPlan-sCT respectively for rCT and and sCT. DVH comparison on ROIs and slice-wise evaluation of dose is performed between AutoPlan-rCT and AutoPlan-sCT. Delivery parameters i.e. beam and corresponding segments from the AutoPlan-sCT are copied over to rCT and dose is computed to get AutoPlan-sCT-on-rCT. Results: Plan evaluation is done based on Dose Volume Histogram (DVH) of ROIs and manual slice-wise inspection of dose distribution. Both AutoPlan-rCT and AutoPlan-sCT provide a clinically acceptable plan. Also, AutoPlan-sCT-on-rCT shows excellent agreement with AutoPlan-sCT. Conclusion: The study demonstrates that it is feasible to do IMRT planning on the simulated CT image obtained from MR image for prostate anatomy. The research is supported by Philips India Ltd.« less
: 0; } .dl-horizontal dt { float: none; width: auto; clear: none; text-align: left; } .dl-horizontal dd { margin-left: 0; } .container { width: auto; } .row-fluid { width: 100%; } .row, .thumbnails [class*="span"] { display: inline-block; width: auto; } .controls-row [class*="span"
Operations Manual for the National Center for Physical Acoustics Infrasound Microphone
2013-02-01
thumbdrive.) There are three sections of the configuration file that can be edited: sensorConfig, adcConfig and autoControl . Modifying any other...for autoControl autoControl = { options = ( { doSchedule = 0; if nonzero, hourly scheduler is enabled
Chao, Xiuhua; Xu, Lei; Li, Jianfeng; Han, Yuechen; Li, Xiaofei; Mao, YanYan; Shang, Haiqiong; Fan, Zhaomin; Wang, Haibo
2016-06-01
Conclusion C/GP hydrogel was demonstrated to be an ideal drug delivery vehicle and scaffold in the vein conduit. Combined use autologous vein and NGF continuously delivered by C/GP-NGF hydrogel can improve the recovery of facial nerve defects. Objective This study investigated the effects of chitosan-β-glycerophosphate-nerve growth factor (C/GP-NGF) hydrogel combined with autologous vein conduit on the recovery of damaged facial nerve in a rat model. Methods A 5 mm gap in the buccal branch of a rat facial nerve was reconstructed with an autologous vein. Next, C/GP-NGF hydrogel was injected into the vein conduit. In negative control groups, NGF solution or phosphate-buffered saline (PBS) was injected into the vein conduits, respectively. Autologous implantation was used as a positive control group. Vibrissae movement, electrophysiological assessment, and morphological analysis of regenerated nerves were performed to assess nerve regeneration. Results NGF continuously released from C/GP-NGF hydrogel in vitro. The recovery rate of vibrissae movement and the compound muscle action potentials of regenerated facial nerve in the C/GP-NGF group were similar to those in the Auto group, and significantly better than those in the NGF group. Furthermore, larger regenerated axons and thicker myelin sheaths were obtained in the C/GP-NGF group than those in the NGF group.
Botros, Andrew; van Dijk, Bas; Killian, Matthijs
2007-05-01
AutoNRT is an automated system that measures electrically evoked compound action potential (ECAP) thresholds from the auditory nerve with the Nucleus Freedom cochlear implant. ECAP thresholds along the electrode array are useful in objectively fitting cochlear implant systems for individual use. This paper provides the first detailed description of the AutoNRT algorithm and its expert systems, and reports the clinical success of AutoNRT to date. AutoNRT determines thresholds by visual detection, using two decision tree expert systems that automatically recognise ECAPs. The expert systems are guided by a dataset of 5393 neural response measurements. The algorithm approaches threshold from lower stimulus levels, ensuring recipient safety during postoperative measurements. Intraoperative measurements use the same algorithm but proceed faster by beginning at stimulus levels much closer to threshold. When searching for ECAPs, AutoNRT uses a highly specific expert system (specificity of 99% during training, 96% during testing; sensitivity of 91% during training, 89% during testing). Once ECAPs are established, AutoNRT uses an unbiased expert system to determine an accurate threshold. Throughout the execution of the algorithm, recording parameters (such as implant amplifier gain) are automatically optimised when needed. In a study that included 29 intraoperative and 29 postoperative subjects (a total of 418 electrodes), AutoNRT determined a threshold in 93% of cases where a human expert also determined a threshold. When compared to the median threshold of multiple human observers on 77 randomly selected electrodes, AutoNRT performed as accurately as the 'average' clinician. AutoNRT has demonstrated a high success rate and a level of performance that is comparable with human experts. It has been used in many clinics worldwide throughout the clinical trial and commercial launch of Nucleus Custom Sound Suite, significantly streamlining the clinical procedures associated with cochlear implant use.
Family factors associated with auto-aggressiveness in adolescents in Croatia.
Tripković, Mara; Francisković, Tanja; Grgić, Neda; Ercegović, Nela; Graovac, Mirjana; Zecević, Iva
2013-12-01
The aim of this research is to look into the roles of families' social situation and cohesion in adolescent auto-aggressiveness in Croatia. The research was conducted on a sample of Zagreb high school students which encompassed 701 pupils of both genders aged 14-19. The basic demographic data were obtained using the Structured Demographic and Family Data Questionnaire. Auto-aggressiveness was tested using a section of the Report on Youth Aged 11-18 and the Scale of Auto-destructiveness--SAD, whereas the family cohesion was tested with the Family Adaptability and Cohesion Evaluation Scales FACES III. The obtained results show differences according to the gender: girls are more prone to auto-aggressiveness than boys (t = -3.385, df = 565, p = 0.001) and girls more often show symptoms of destructiveness (t = -3.809, df = 637, p < 0.001) and anxiety (t = -6.562, df = 640, p < 0.001), while boys show pronounced aggressiveness (t = 2.655, df = 653, p = 0.008). Significant family factors associated with auto-aggressiveness are parents' marital status (chi2 = 18.039, df = 4, p = 0.001), their financial situation (F(2.548) = 4.604, p = 0.010), alcoholic father (chi2 = 9.270, df = 2, p = 0.010), mentally ill mother (t = 5.264, df = 541, p < 0.001), as well as mentally ill father (t = 4.744, df = 529, p < 0.001), and corporal punishment by mother (F(2.542) = 8.132, p < 0.001) or father (F(2.530) = 5.341, p = 0.005). Adolescents from split families show more auto-aggressiveness. Family cohesion appears to be considerably associated with auto-aggressiveness and the adolescents that see their families as less cohesive have more mental problems (chi2 = 29.98, df = 2, p < 0.001). There is a connection between auto-destructive behavior in adolescents and family factors. Knowledge of family's social situation and cohesion may help understand, prevent and treat auto-aggressiveness in adolescents.
[Oral diseases in auto-immune polyendocrine syndrome type 1].
Proust-Lemoine, Emmanuelle; Guyot, Sylvie
2017-09-01
Auto-immune polyendocrine syndrome type 1 (APS1) also called Auto-immune Polyendocrinopathy Candidiasis Ectodermal Dystrophy (APECED) is a rare monogenic childhood-onset auto-immune disease. This autosomal recessive disorder is caused by mutations in the auto-immune regulator (AIRE) gene, and leads to autoimmunity targeting peripheral tissues. There is a wide variability in clinical phenotypes in patients with APSI, with auto-immune endocrine and non-endocrine disorders, and chronic mucocutaneous candidiasis. These patients suffer from oral diseases such as dental enamel hypoplasia and candidiasis. Both are frequently described, and in recent series, enamel hypoplasia and candidiasis are even the most frequent components of APS1 together with hypoparathyroidism. Both often occur during childhood (before 5 years old for canrdidiasis, and before 15 years old for enamel hypoplasia). Oral candidiasis is recurrent all life long, could become resistant to azole antifungal after years of treatment, and be carcinogenic, leading to severe oral squamous cell carcinoma. Oral components of APS1 should be diagnosed and rigorously treated. Dental enamel hypoplasia and/or recurrent oral candidiasis in association with auto-immune diseases in a young child should prompt APS1 diagnosis. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Auto-fusion and the shaping of neurons and tubes.
Soulavie, Fabien; Sundaram, Meera V
2016-12-01
Cells adopt specific shapes that are necessary for specific functions. For example, some neurons extend elaborate arborized dendrites that can contact multiple targets. Epithelial and endothelial cells can form tiny seamless unicellular tubes with an intracellular lumen. Recent advances showed that cells can auto-fuse to acquire those specific shapes. During auto-fusion, a cell merges two parts of its own plasma membrane. In contrast to cell-cell fusion or macropinocytic fission, which result in the merging or formation of two separate membrane bound compartments, auto-fusion preserves one compartment, but changes its shape. The discovery of auto-fusion in C. elegans was enabled by identification of specific protein fusogens, EFF-1 and AFF-1, that mediate cell-cell fusion. Phenotypic characterization of eff-1 and aff-1 mutants revealed that fusogen-mediated fusion of two parts of the same cell can be used to sculpt dendritic arbors, reconnect two parts of an axon after injury, or form a hollow unicellular tube. Similar auto-fusion events recently were detected in vertebrate cells, suggesting that auto-fusion could be a widely used mechanism for shaping neurons and tubes. Copyright © 2016 Elsevier Ltd. All rights reserved.
Patterns of synchrony for feed-forward and auto-regulation feed-forward neural networks.
Aguiar, Manuela A D; Dias, Ana Paula S; Ferreira, Flora
2017-01-01
We consider feed-forward and auto-regulation feed-forward neural (weighted) coupled cell networks. In feed-forward neural networks, cells are arranged in layers such that the cells of the first layer have empty input set and cells of each other layer receive only inputs from cells of the previous layer. An auto-regulation feed-forward neural coupled cell network is a feed-forward neural network where additionally some cells of the first layer have auto-regulation, that is, they have a self-loop. Given a network structure, a robust pattern of synchrony is a space defined in terms of equalities of cell coordinates that is flow-invariant for any coupled cell system (with additive input structure) associated with the network. In this paper, we describe the robust patterns of synchrony for feed-forward and auto-regulation feed-forward neural networks. Regarding feed-forward neural networks, we show that only cells in the same layer can synchronize. On the other hand, in the presence of auto-regulation, we prove that cells in different layers can synchronize in a robust way and we give a characterization of the possible patterns of synchrony that can occur for auto-regulation feed-forward neural networks.
Genotoxic damage in auto body shop workers.
Siebel, Anna Maria; Basso da Silva, Luciano
2010-10-01
Some studies have shown increased DNA damage among car painters, but other professionals working in auto body and paint shops have not been extensively assessed. The aim of this study was to assess DNA damage in different types of auto body shop workers by measuring micronucleus (MN) levels in exfoliated buccal cells. The mean number of cells with MN per 2000 exfoliated buccal cells was analyzed in three groups of male workers: auto body repair technicians, painters, and office workers (control group). All participants answered a questionnaire inquiring about age, smoking habits, alcohol consumption, work practices, occupational exposure time, job activities, and use of protective equipment. The mean number of cells with MN was 3.50 ± 1.50 in auto body painters, 3.91 ± 2.10 in auto body repair technicians, and 0.80 ± 0.78 in office workers, with a significant difference between the control group and the two other groups (p = 0.0001). Age, occupational exposure time, use of protective masks, alcohol consumption, and smoking habit did not affect MN results. The findings indicate that technicians and painters working in auto body shops are at risk for genotoxic damage, while office workers seem to be protected.
Telemetry Standards, IRIG Standard 106-17, Chapter 22, Network Based Protocol Suite
2017-07-01
ER Fiber media connections using 10 Gigabit Ethernet shall comply with IEEE 802.3-2012, Section 5, Clause 52. 22.2.1.1.4 Auto- Negotiation ...22.2.1.1.4.1 Copper Auto- Negotiation Copper media connections, as described in the preceding sections, shall support auto- negotiation of speed, duplex, and...flow control in the manner specified in IEEE 802.3-2012, Section 2, Clause 28. 22.2.1.1.4.2 Fiber Auto- Negotiation Gigabit and 10 Gigabit fiber
A Code Generation Approach for Auto-Vectorization in the Spade Compiler
NASA Astrophysics Data System (ADS)
Wang, Huayong; Andrade, Henrique; Gedik, Buğra; Wu, Kun-Lung
We describe an auto-vectorization approach for the Spade stream processing programming language, comprising two ideas. First, we provide support for vectors as a primitive data type. Second, we provide a C++ library with architecture-specific implementations of a large number of pre-vectorized operations as the means to support language extensions. We evaluate our approach with several stream processing operators, contrasting Spade's auto-vectorization with the native auto-vectorization provided by the GNU gcc and Intel icc compilers.
Algorithm for automatic analysis of electro-oculographic data
2013-01-01
Background Large amounts of electro-oculographic (EOG) data, recorded during electroencephalographic (EEG) measurements, go underutilized. We present an automatic, auto-calibrating algorithm that allows efficient analysis of such data sets. Methods The auto-calibration is based on automatic threshold value estimation. Amplitude threshold values for saccades and blinks are determined based on features in the recorded signal. The performance of the developed algorithm was tested by analyzing 4854 saccades and 213 blinks recorded in two different conditions: a task where the eye movements were controlled (saccade task) and a task with free viewing (multitask). The results were compared with results from a video-oculography (VOG) device and manually scored blinks. Results The algorithm achieved 93% detection sensitivity for blinks with 4% false positive rate. The detection sensitivity for horizontal saccades was between 98% and 100%, and for oblique saccades between 95% and 100%. The classification sensitivity for horizontal and large oblique saccades (10 deg) was larger than 89%, and for vertical saccades larger than 82%. The duration and peak velocities of the detected horizontal saccades were similar to those in the literature. In the multitask measurement the detection sensitivity for saccades was 97% with a 6% false positive rate. Conclusion The developed algorithm enables reliable analysis of EOG data recorded both during EEG and as a separate metrics. PMID:24160372
Algorithm for automatic analysis of electro-oculographic data.
Pettersson, Kati; Jagadeesan, Sharman; Lukander, Kristian; Henelius, Andreas; Haeggström, Edward; Müller, Kiti
2013-10-25
Large amounts of electro-oculographic (EOG) data, recorded during electroencephalographic (EEG) measurements, go underutilized. We present an automatic, auto-calibrating algorithm that allows efficient analysis of such data sets. The auto-calibration is based on automatic threshold value estimation. Amplitude threshold values for saccades and blinks are determined based on features in the recorded signal. The performance of the developed algorithm was tested by analyzing 4854 saccades and 213 blinks recorded in two different conditions: a task where the eye movements were controlled (saccade task) and a task with free viewing (multitask). The results were compared with results from a video-oculography (VOG) device and manually scored blinks. The algorithm achieved 93% detection sensitivity for blinks with 4% false positive rate. The detection sensitivity for horizontal saccades was between 98% and 100%, and for oblique saccades between 95% and 100%. The classification sensitivity for horizontal and large oblique saccades (10 deg) was larger than 89%, and for vertical saccades larger than 82%. The duration and peak velocities of the detected horizontal saccades were similar to those in the literature. In the multitask measurement the detection sensitivity for saccades was 97% with a 6% false positive rate. The developed algorithm enables reliable analysis of EOG data recorded both during EEG and as a separate metrics.
Casein Kinase 2 Reverses Tail-Independent Inhibition of Kinesin-1
NASA Astrophysics Data System (ADS)
Xu, Jing; Shu, Zhanyong; Anand, Preetha; Reddy, Babu; Cermelli, Silvia; Whisenant, Thomas; King, Stephen; Bardwell, Lee; Huang, Lan; Gross, Steven
2011-03-01
Kinesin-1 is a plus-end microtubule-based molecular motor, and defects in kinesin transport are linked to diseases including neurodegeneration. Kinesin can auto-inhibit via a direct head-tail interaction, but is believed to be active otherwise. In contrast, this study uncovers a fast but reversible inhibition distinct from the canonical auto-inhibition pathway. The majority of the initially active kinesin (full-length or tail-less) loses its ability to bind/interact with microtubule, and Casein Kinase 2 (CK2) reverses this inactivation (up to 4-fold) without altering kinesin's single motor properties. Motor phosphorylation is not required for this CK2 -mediated kinesin activation. In cultured mammalian cells, knockdown of CK2 level, but not kinase activity, was sufficient to decrease the force required to stall lipid droplet transport, consistent with a reduction in the number of active motors. We propose that CK2 forms a positive regulating complex with the motor. This study provides the first direct evidence of a protein kinase positively regulating kinesin-transport, and uncovers a pathway whereby inactive cargo-bound kinesin can be activated. This work is supported by NIGMS grants GM64624 and GM079156 to SPG, GM-74830 to LH, NIH grants GM76516 and GM60366 to LB, and AHA grant 825278F to JX.
Epperla, Narendranath; Shah, Namrata; Hamadani, Mehdi; Richardson, Kristin; Kapke, Jonathan T; Patel, Asmita; Teegavarapu, Sravanthi P; Carrum, George; Hari, Parameswaran N; Pingali, Sai R; Karmali, Reem; Fenske, Timothy S
2016-12-01
For patients with relapsed or refractory diffuse large B-cell lymphoma (DLBCL), autologous hematopoietic cell transplantation (auto-HCT) is commonly used. After auto-HCT, DLBCL patients are often monitored with surveillance imaging. However, there is little evidence to support this practice. We performed a multicenter retrospective study of DLBCL patients who underwent auto-HCT (n = 160), who experienced complete remission after transplantation, and who then underwent surveillance imaging. Of these, only 45 patients experienced relapse after day +100 after auto-HCT, with relapse detected by routine imaging in 32 (71%) and relapse detected clinically in 13 (29%). Baseline patient characteristics were similar between the 2 groups. Comparing the radiographic and clinically detected relapse groups, the median time from diagnosis to auto-HCT (389 days vs. 621 days, P = .06) and the median follow-up after auto-HCT (2464 days vs. 1593 days P = .60) were similar. The median time to relapse after auto-HCT was 191 days in radiographically detected relapses compared to 492 days in clinically detected relapses (P = .35), and median postrelapse survival was 359 days in such patients compared to 123 days in patients with clinically detected relapse (P = .36). However, the median posttransplantation overall survival was not significantly different for patients with relapse detected by routine imaging versus relapse detected clinically (643 vs. 586 days, P = .68). A majority (71%) of DLBCL relapses after auto-HCT are detected by routine surveillance imaging. Overall, there appears to be limited utility for routine imaging after auto-HCT except in select cases where earlier detection and salvage therapy with allogeneic HCT is a potential option. Copyright © 2016 Elsevier Inc. All rights reserved.
Epperla, Narendranath; Fenske, Timothy S; Hari, Parameswaran N; Hamadani, Mehdi
2015-01-01
Lymphomas constitute the second most common indication for high dose therapy (HDT) followed by autologous hematopoietic cell transplantation (auto-HCT). The intent of administering HDT in these heterogeneous disorders varies from cure (e.g., in relapsed aggressive lymphomas) to disease control (e.g., most indolent lymphomas). Regardless of the underlying histology or remission status at transplantation, disease relapse remains the number one cause of post auto-HCT therapy failure and mortality. The last decade has seen a proliferation of clinical studies looking at prevention of post auto-HCT therapy failure with various maintenance strategies. The benefit of such therapies is in turn dependent on disease histology and timing of transplantation. In relapsed, chemosensitive diffuse large B-cell lymphoma (DLBCL), although post auto-HCT maintenance rituximab seems to be safe and feasible, it does not provide improved survival outcomes and is not recommended. The preliminary results with anti- programmed death -1 (PD-1) antibody therapy as post auto-HCT maintenance in DLBCL is promising but requires randomized validation. Similarly in follicular lymphoma, maintenance therapies including rituximab following auto-HCT should be considered investigational and offered only on a clinical trial. Rituximab maintenance results in improved progression-free survival but has not yet shown to improve overall survival in mantle cell lymphoma (MCL), but given the poor prognosis with post auto-HCT failure in MCL, maintenance rituximab can be considered on a case-by-case basis. Ongoing trials evaluating the efficacy of post auto-HCT maintenance with novel compounds (e.g., immunomodulators, PD-1 inhibitors, proteasome inhibitors and bruton’s tyrosine kinase inhibitors) will likely change the practice landscape in the near future for B cell non-Hodgkin lymphomas patients following HDT and auto-HCT. PMID:26421260
Anti-neuropeptide Y plasma immunoglobulins in relation to mood and appetite in depressive disorder.
Garcia, Frederico D; Coquerel, Quentin; do Rego, Jean-Claude; Cravezic, Aurore; Bole-Feysot, Christine; Kiive, Evelyn; Déchelotte, Pierre; Harro, Jaanus; Fetissov, Sergueï O
2012-09-01
Depression and eating disorders are frequently associated, but the molecular pathways responsible for co-occurrence of altered mood, appetite and body weight are not yet fully understood. Neuropeptide Y (NPY) has potent antidepressant and orexigenic properties and low central NPY levels have been reported in major depression. In the present study, we hypothesized that in patients with major depression alteration of mood, appetite and body weight may be related to NPY-reactive autoantibodies (autoAbs). To test this hypothesis, we compared plasma levels and affinities of NPY-reactive autoAbs between patients with major depression and healthy controls. Then, to evaluate if changes of NPY autoAb properties can be causally related to altered mood and appetite, we developed central and peripheral passive transfer models of human autoAbs in mice and studied depressive-like behavior in forced-swim test and food intake. We found that plasma levels of NPY IgG autoAbs were lower in patients with moderate but not with mild depression correlating negatively with the Montgomery-Åsberg Depression Rating Scale scores and with immobility time of the forced-swim test in mice after peripheral injection of autoAbs. No significant differences in NPY IgG autoAb affinities between patients with depression and controls were found, but higher affinity of IgG autoAbs for NPY was associated with lower body mass index and prevented NPY-induced orexigenic response in mice after their central injection. These data suggest that changes of plasma levels of anti-NPY autoAbs are relevant to altered mood, while changes of their affinity may participate in altered appetite and body weight in patients with depressive disorder. Copyright © 2012 Elsevier Ltd. All rights reserved.
Appeltshauser, Luise; Weishaupt, Andreas; Sommer, Claudia; Doppler, Kathrin
2017-01-01
Inflammatory neuropathies associated with auto-antibodies against paranodal proteins like contactin-1 are reported to respond poorly to treatment with intravenous immunoglobulins (IVIG). A reason might be that IVIG interacts with the complement pathway and these auto-antibodies often belong to the IgG4 subclass that does not activate complement. However, some patients do show a response to IVIG, especially at the beginning of the disease. This corresponds with the finding of coexisting IgG subclasses IgG1, IgG2 and IgG3. We therefore aimed to investigate complement deposition and activation by samples of three patients with anti-contactin-1 IgG auto-antibodies of different subclasses as a potential predictor for response to IVIG. Complement deposition and activation was measured by cell binding and ELISA based assays, and the effect of IVIG on complement deposition was assessed by addition of different concentrations of IVIG. Binding of anti-contactin-1 auto-antibodies of all three patients induced complement deposition and activation with the strongest effect shown by the serum of a patient with predominance of IgG3 auto-antibodies. IVIG led to a reduction of complement deposition in a dose-dependent manner, but did not reduce binding of auto-antibodies to contactin-1. We conclude that complement deposition may contribute to the pathophysiology of anti-contactin-1 associated neuropathy, particularly in patients with predominance of the IgG3 subclass. The proportion of different auto-antibody subclasses may be a predictor for the response to IVIG in patients with auto-antibodies against paranodal proteins. Copyright © 2016 Elsevier Inc. All rights reserved.
Ambient-temperature co-oxidation catalysts
NASA Technical Reports Server (NTRS)
Upchurch, Billy T.; Schryer, David R.; Brown, Kenneth G.; Kielin, Erik J.
1991-01-01
Oxidation catalysts which operate at ambient temperature were developed for the recombination of carbon monoxide (CO) and oxygen (O2) dissociation products which are formed during carbon dioxide (CO2) laser operation. Recombination of these products to regenerate CO2 allows continuous operation of CO2 lasers in a closed cycle mode. Development of these catalyst materials provides enabling technology for the operation of such lasers from space platforms or in ground based facilities without constant gas consumption required for continuous open cycle operation. Such catalysts also have other applications in various areas outside the laser community for removal of CO from other closed environments such as indoor air and as an ambient temperature catalytic converter for control of auto emissions.
EMISSIONS FROM COATINGS USED IN THE AUTO REFINISHING INDUSTRY
The report presents results of EPA Methods 24 and 311 analyses of the volatile organic compound (VOC) content of selected auto refinishing coatings and their components that are sold by the five major auto coating manufacturers. These analyses were undertaken to determine the acc...
40 CFR 49.144 - Control equipment requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... remote notification system if the pilot flame fails. (B) An electronically controlled auto-ignition... emissions; (iv) The pit flare is equipped with an electronically controlled auto-ignition system with a... electronically controlled auto-ignition system must be repaired or replaced before the pit flare is utilized...
40 CFR 49.144 - Control equipment requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... remote notification system if the pilot flame fails. (B) An electronically controlled auto-ignition... emissions; (iv) The pit flare is equipped with an electronically controlled auto-ignition system with a... electronically controlled auto-ignition system must be repaired or replaced before the pit flare is utilized...
2012-01-01
Background Structured association mapping is proving to be a powerful strategy to find genetic polymorphisms associated with disease. However, these algorithms are often distributed as command line implementations that require expertise and effort to customize and put into practice. Because of the difficulty required to use these cutting-edge techniques, geneticists often revert to simpler, less powerful methods. Results To make structured association mapping more accessible to geneticists, we have developed an automatic processing system called Auto-SAM. Auto-SAM enables geneticists to run structured association mapping algorithms automatically, using parallelization. Auto-SAM includes algorithms to discover gene-networks and find population structure. Auto-SAM can also run popular association mapping algorithms, in addition to five structured association mapping algorithms. Conclusions Auto-SAM is available through GenAMap, a front-end desktop visualization tool. GenAMap and Auto-SAM are implemented in JAVA; binaries for GenAMap can be downloaded from http://sailing.cs.cmu.edu/genamap. PMID:22471660
A Real-Time Non-invasive Auto-bioluminescent Urinary Bladder Cancer Xenograft Model.
John, Bincy Anu; Xu, Tingting; Ripp, Steven; Wang, Hwa-Chain Robert
2017-02-01
The study was to develop an auto-bioluminescent urinary bladder cancer (UBC) xenograft animal model for pre-clinical research. The study used a humanized, bacteria-originated lux reporter system consisting of six (luxCDABEfrp) genes to express components required for producing bioluminescent signals in human UBC J82, J82-Ras, and SW780 cells without exogenous substrates. Immune-deficient nude mice were inoculated with Lux-expressing UBC cells to develop auto-bioluminescent xenograft tumors that were monitored by imaging and physical examination. Lux-expressing auto-bioluminescent J82-Lux, J82-Ras-Lux, and SW780-Lux cell lines were established. Xenograft tumors derived from tumorigenic Lux-expressing auto-bioluminescent J82-Ras-Lux cells allowed a serial, non-invasive, real-time monitoring by imaging of tumor development prior to the presence of palpable tumors in animals. Using Lux-expressing auto-bioluminescent tumorigenic cells enabled us to monitor the entire course of xenograft tumor development through tumor cell implantation, adaptation, and growth to visible/palpable tumors in animals.
Akhtar, S; Youssef, I; Soudy, H; Elhassan, T A M; Rauf, S M; Maghfoor, I
2015-12-01
Data are limited regarding the prevalence of menstrual cycles and pregnancies after high-dose chemotherapy (HDC) and auto-stem cell transplantation (SCT). Female patients who underwent HDC auto-SCT for non-Hodgkin and Hodgkin lymphoma (1997-2012) were reviewed. The selection criteria were as follows: (1) alive without disease 12 and 24 months after auto-SCT for menstrual cycles and pregnancy, respectively, (2) age <40 years at auto-SCT, and (3) no primary infertility. One-hundred and seventy-six females underwent single auto-SCT. Eighty-nine were eligible for menstrual cycles and pregnancy analysis. Median age at auto-SCT was 25 years (14-40 years), at pregnancy 27 years (20-37 years), median follow-up 65 months (range 24-190). Regular menstrual-cycles resumed in 56/89 patients (63%). Increasing age (P=0.02) and number of prior chemotherapy cycles (P=0.02) are associated with higher risk of amenorrhea. Forty patients tried to get pregnant, 26 (65%) became pregnant 50 times: 43 (86%) live birth, 7 (14%) miscarriage and 2/50 had birth defects. Twenty-four patients practiced breastfeeding (median duration 4 months (1-24 months)). Enough breast milk production was reported 62.5% vs 100% in those patients who did or did not receive above the diaphragm radiation therapy, respectively, (P=0.066). Our data highlights significantly higher than perceived incidence of menstrual cycle resumption, successful pregnancies and breastfeeding after HDC auto-SCT.
Gan, Kok Beng; Azeez, Dhifaf; Umat, Cila; Ali, Mohd Alauddin Mohd; Wahab, Noor Alaudin Abdul; Mukari, Siti Zamratol Mai-Sarah
2012-10-01
Hearing screening is important for the early detection of hearing loss. The requirements of specialized equipment, skilled personnel, and quiet environments for valid screening results limit its application in schools and health clinics. This study aimed to develop an automated hearing screening kit (auto-kit) with the capability of realtime noise level monitoring to ensure that the screening is performed in an environment that conforms to the standard. The auto-kit consists of a laptop, a 24-bit resolution sound card, headphones, a microphone, and a graphical user interface, which is calibrated according to the American National Standards Institute S3.6-2004 standard. The auto-kit can present four test tones (500, 1000, 2000, and 4000 Hz) at 25 or 40 dB HL screening cut-off level. The clinical results at 40 dB HL screening cut-off level showed that the auto-kit has a sensitivity of 92.5% and a specificity of 75.0%. Because the 500 Hz test tone is not included in the standard hearing screening procedure, it can be excluded from the auto-kit test procedure. The exclusion of 500 Hz test tone improved the specificity of the auto-kit from 75.0% to 92.3%, which suggests that the auto-kit could be a valid hearing screening device. In conclusion, the auto-kit may be a valuable hearing screening tool, especially in countries where resources are limited.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Y; Gardner, S; Liu, C
2016-06-15
Purpose: To present a novel positioning strategy which optimizes radiation delivery with radiobiological response knowledge, and to evaluate its application during prostate external beam radiotherapy. Methods: Ten patients with low or intermediate risk prostate cancer were evaluated retrospectively in this IRB-approved study. For each patient, a VMAT plan was generated on the planning CT (PCT) to deliver 78 Gy in 39 fractions with PTV = prostate + 7 mm margin, except for 5mm in the posterior direction. Five representative pretreatment CBCT images were selected for each patient, and prostate, rectum, and bladder were delineated on all CBCT images. Each CBCTmore » was auto-registered to the corresponding PCT. Starting from this auto-matched position (AM-position), a search for optimal treatment position was performed utilizing a score function based on radiobiological and dosimetric indices (D98-DTV, NTCP-rectum, and NTCP-bladder) for the daily target volume (DTV), rectum, and bladder. DTV was defined as prostate + 4 mm margin to account for intra-fraction motion as well as contouring variability on CBCT. We termed the optimal treatment position the radiobiologically optimized couch shift position (ROCS-position). Results: The indices, averaged over the 10 patients’ treatment plans, were (mean±SD): 77.7±0.2 Gy (D98-PTV), 12.3±2.7% (NTCP-rectum), and 53.2±11.2% (NTCP-bladder). The corresponding values calculated on all 50 CBCT images at the AM-positions were 72.9±11.3 Gy (D98-DTV), 15.8±6.4% (NTCP-rectum), and 53.0±21.1% (NTCP-bladder), respectively. In comparison, calculated on CBCT at the ROCS-positions, the indices were 77.0±2.1 Gy (D98-DTV), 12.1±5.7% (NTCP-rectum), and 60.7±16.4% (NTCP-bladder). Compared to autoregistration, ROCS-optimization recovered dose coverage to target volume and lowered the risk to rectum. Moreover, NTCPrectum for one patient remained high after ROCS-optimization and therefore could potentially benefit from adaptive planning. Conclusion: These encouraging results illustrate the potential utility of applying radiobiologically optimized correction for online image-guided radiotherapy of prostate patients.« less
Balti, Eric V; Vandemeulebroucke, Evy; Weets, Ilse; Van De Velde, Ursule; Van Dalem, Annelien; Demeester, Simke; Verhaeghen, Katrijn; Gillard, Pieter; De Block, Christophe; Ruige, Johannes; Keymeulen, Bart; Pipeleers, Daniel G; Decochez, Katelijn; Gorus, Frans K
2015-02-01
In preparation of future prevention trials, we aimed to identify predictors of 3-year diabetes onset among oral glucose tolerance test (OGTT)- and hyperglycemic clamp-derived metabolic markers in persistently islet autoantibody positive (autoAb(+)) offspring and siblings of patients with type 1 diabetes (T1D). The design is a registry-based study. Functional tests were performed in a hospital setting. Persistently autoAb(+) first-degree relatives of patients with T1D (n = 81; age 5-39 years). We assessed 3-year predictive ability of OGTT- and clamp-derived markers using receiver operating characteristics (ROC) and Cox regression analysis. Area under the curve of clamp-derived first-phase C-peptide release (AUC(5-10 min); min 5-10) was determined in all relatives and second-phase release (AUC(120-150 min); min 120-150) in those aged 12-39 years (n = 62). Overall, the predictive ability of AUC(5-10 min) was better than that of peak C-peptide, the best predictor among OGTT-derived parameters (ROC-AUC [95%CI]: 0.89 [0.80-0.98] vs 0.81 [0.70-0.93]). Fasting blood glucose (FBG) and AUC(5-10 min) provided the best combination of markers for prediction of diabetes within 3 years; (ROC-AUC [95%CI]: 0.92 [0.84-1.00]). In multivariate Cox regression analysis, AUC(5-10 min)) (P = .001) was the strongest independent predictor and interacted significantly with all tested OGTT-derived parameters. AUC(5-10 min) below percentile 10 of controls was associated with 50-70% progression to T1D regardless of age. Similar results were obtained for AUC(120-150 min). Clamp-derived first-phase C-peptide release can be used as an efficient and simple screening strategy in persistently autoAb(+) offspring and siblings of T1D patients to predict impending diabetes.
14 CFR 61.67 - Category II pilot authorization requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... and runway lighting system; (ix) Characteristics and limitations of the flight director system, auto approach coupler (including split axis type if equipped), auto throttle system (if equipped), and other... be made with the use of an approved flight control guidance system, except if an approved auto...
Alternative Fuels Infrastructure Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bloyd, Cary N.; Stork, Kevin
This summary reviews the status of alternate transportation fuels development and utilization in Thailand. Thailand has continued to work to promote increased consumption of gasohol especially for highethanol content fuels like E85. The government has confirmed its effort to draw up incentives for auto makers to invest in manufacturing E85-compatible vehicles in the country. An understanding of the issues and experiences associated with the introduction of alternative fuels in other countries can help the US in anticipation potential problems as it introduces new automotive fuels.
Auto Body Repair. Supplementary Units. Instructor Key and Student Units.
ERIC Educational Resources Information Center
Daniel, Linda; Muench, James F., Ed.
These supplementary units are designed to help students with special needs learn and apply auto body repair skills. The material specifically supplements the Auto Body Repair Curriculum Guide (University of Missouri-Columbia 1988), and is intended for instructors serving the occupational needs of various categories of disadvantaged and handicapped…
46 CFR 28.875 - Radar, depth sounding, and auto-pilot.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 1 2013-10-01 2013-10-01 false Radar, depth sounding, and auto-pilot. 28.875 Section 28.875 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.875 Radar, depth sounding, and auto-pilot...
46 CFR 28.875 - Radar, depth sounding, and auto-pilot.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 1 2014-10-01 2014-10-01 false Radar, depth sounding, and auto-pilot. 28.875 Section 28.875 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.875 Radar, depth sounding, and auto-pilot...
12 CFR 222.75 - Rules of construction.
Code of Federal Regulations, 2011 CFR
2011-01-01
... of an automobile. If the auto dealer is the person to whom the loan obligation is initially payable, such as where the auto dealer is the original creditor under a retail installment sales contract, the auto dealer must provide the risk-based pricing notice to the consumer (or satisfy the requirements for...
12 CFR 222.75 - Rules of construction.
Code of Federal Regulations, 2013 CFR
2013-01-01
... of an automobile. If the auto dealer is the person to whom the loan obligation is initially payable, such as where the auto dealer is the original creditor under a retail installment sales contract, the auto dealer must provide the risk-based pricing notice to the consumer (or satisfy the requirements for...
12 CFR 222.75 - Rules of construction.
Code of Federal Regulations, 2014 CFR
2014-01-01
... of an automobile. If the auto dealer is the person to whom the loan obligation is initially payable, such as where the auto dealer is the original creditor under a retail installment sales contract, the auto dealer must provide the risk-based pricing notice to the consumer (or satisfy the requirements for...
46 CFR 28.875 - Radar, depth sounding, and auto-pilot.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 1 2012-10-01 2012-10-01 false Radar, depth sounding, and auto-pilot. 28.875 Section 28.875 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.875 Radar, depth sounding, and auto-pilot...
12 CFR 222.75 - Rules of construction.
Code of Federal Regulations, 2012 CFR
2012-01-01
... of an automobile. If the auto dealer is the person to whom the loan obligation is initially payable, such as where the auto dealer is the original creditor under a retail installment sales contract, the auto dealer must provide the risk-based pricing notice to the consumer (or satisfy the requirements for...
An Instructional Method for the AutoCAD Modeling Environment.
ERIC Educational Resources Information Center
Mohler, James L.
1997-01-01
Presents a command organizer for AutoCAD to aid new uses in operating within the 3-D modeling environment. Addresses analyzing the problem, visualization skills, nonlinear tools, a static view of a dynamic model, the AutoCAD organizer, environment attributes, and control of the environment. Contains 11 references. (JRH)
Programmable Applications: Interpreter Meets Interface
1991-10-01
ics program written for professional architects and designers, and including a huge library of files written in AutoLisp , a "design-enriched" Lisp... AutoLisp procedures). The choice of Lisp as a base language is a happy one for AutoCAD; the application has clearly benefitted from the contribution
46 CFR 28.875 - Radar, depth sounding, and auto-pilot.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Radar, depth sounding, and auto-pilot. 28.875 Section 28.875 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.875 Radar, depth sounding, and auto-pilot...
78 FR 23688 - Airworthiness Directives; Bell Helicopter Textron Canada Inc. Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-22
... would require replacing certain part-numbered engine auto-relight kit control boxes. This proposed AD is... range requirements, which could cause the control box to malfunction, disabling the engine auto-relight... helicopters with an engine auto-relight kit control box assembly (control box assembly) part number 206-375...
Auto Collision Technician: An Instructional Guide for Teachers.
ERIC Educational Resources Information Center
Ohio State Univ., Columbus. Vocational Instructional Materials Lab.
This guide is designed to help teachers in auto collision technician programs for grades 11 and 12 teach the critical competencies of the program. The critical competencies covered are the High Priority-Individual (HP-I) competencies in Ohio's Occupational Competency Assessment Profile (OCAP) for Auto Collision Technician. HP-I competencies are…
New Technologies, New Curricula.
ERIC Educational Resources Information Center
Speidel, Gisela E.
1995-01-01
This article describes the AutoCAD Laboratory at Hawaii's Kamehameha Secondary Schools, offering the perspective of the AutoCAD instructor and Technology Department Head, looking at a day in the AutoCAD Laboratory, and explaining how teaching students about computer-assisted design and drafting can prepare them for college or careers. (SM)
1991-03-21
sectional representation of the spatial figure can be correctly determined. 6 The AutoLisp language system in the AutoCAD software provides the most...softwares are developed on the 32-bit machines and little progress has been reported for the 16-bit machines. Even the AutoCAD is a two-ard-a-half... AutoCAD software as the basis, developed the design package of 3-D cartridge valve blocks on IM PC/AT. To realize the 3-D displaying of cartridge valves
NASA Astrophysics Data System (ADS)
Bell, L. R.; Dowling, J. A.; Pogson, E. M.; Metcalfe, P.; Holloway, L.
2017-01-01
Accurate, efficient auto-segmentation methods are essential for the clinical efficacy of adaptive radiotherapy delivered with highly conformal techniques. Current atlas based auto-segmentation techniques are adequate in this respect, however fail to account for inter-observer variation. An atlas-based segmentation method that incorporates inter-observer variation is proposed. This method is validated for a whole breast radiotherapy cohort containing 28 CT datasets with CTVs delineated by eight observers. To optimise atlas accuracy, the cohort was divided into categories by mean body mass index and laterality, with atlas’ generated for each in a leave-one-out approach. Observer CTVs were merged and thresholded to generate an auto-segmentation model representing both inter-observer and inter-patient differences. For each category, the atlas was registered to the left-out dataset to enable propagation of the auto-segmentation from atlas space. Auto-segmentation time was recorded. The segmentation was compared to the gold-standard contour using the dice similarity coefficient (DSC) and mean absolute surface distance (MASD). Comparison with the smallest and largest CTV was also made. This atlas-based auto-segmentation method incorporating inter-observer variation was shown to be efficient (<4min) and accurate for whole breast radiotherapy, with good agreement (DSC>0.7, MASD <9.3mm) between the auto-segmented contours and CTV volumes.
Co-autodisplay of Z-domains and bovine caseins on the outer membrane of E. coli.
Yoo, Gu; Saenger, Thorsten; Bong, Ji-Hong; Jose, Joachim; Kang, Min-Jung; Pyun, Jae-Chul
2015-12-01
In this work, two proteins, Z-domains and bovine casein, were auto-displayed on the outer membrane of the same Escherichia coli cells by co-transformation of two different auto-display vectors. On the basis of SDS-PAGE densitometry, Z-domains and bovine casein were expressed at 3.12 × 10⁵ and 1.55 × 10⁵ proteins/E. coli cell, respectively. The co-auto-displayed Z-domains had antibody-binding activity and the bovine casein had adhesive properties. E. coli with co-auto-displayed proteins were analyzed by fluorescence assisted cell sorting (FACS). E. coli with co-auto-displayed Z-domains and bovine casein aggregated due to hydrophobic interaction. For application to immunoassays, the Z-domain activity was estimated after (1) immobilizing the E. coli and (2) forming an OM layer. E. coli with co-auto-displayed two proteins that were immobilized on a polystyrene microplate had the same antibody-binding activity as did E. coli with auto-displayed Z-domains only. The OM layer from the co-transformed E. coli had Z-domains and bovine casein expressed at a 1:2 ratio from antibody-binding activity measurements. Copyright © 2015 Elsevier B.V. All rights reserved.
The auto-amputated adnexa: a review of findings in a pediatric population.
Focseneanu, Mariel A; Omurtag, Kenan; Ratts, Valerie S; Merritt, Diane F
2013-12-01
To quantify our experience and that of the literature with diagnosis and management of the auto-amputated adnexa in a pediatric population. Case series and literature review. Tertiary care medical center. Case series of pediatric patients (<18 years of age) with surgically documented adnexal auto-amputation collected from our medical center and the literature. None. Auto-amputated adnexa. In addition to the 3 cases discussed from our institution, 91 cases of auto-amputated adnexa were identified in the literature dating back to 1943, for a total of 94 cases. Forty-nine percent (46/94) of the cases involved girls in a pediatric population (<18 years of age). Of these, the majority (n = 26) were identified in a subgroup of girls who were diagnosed with an adnexal cyst by antenatal ultrasound. Most of these neonates were asymptomatic at birth or had a palpable abdominal mass (n = 6) and at the time of surgical exploration were found to have an auto-amputated adnexa. 34 out of 46 cases were analyzed in detail. The right adnexa were involved in 56% of the cases. The most common presenting complaint verbalized by the older girls was pain; however, 8 cases were identified in asymptomatic girls undergoing unrelated diagnostic testing. The auto-amputated adnexa is a rare finding in the pediatric population, but it must be considered as a possible explanation for the incidental finding of absence of the fallopian tube or ovary in the subgroup of patients who undergo surgery for any reason. Patients with an antecedent history of pelvic pain either chronic or intermittent in nature may be diagnosed with torsion or less frequently auto-amputation of the adnexa. A fetal "pelvic mass" or "ovarian cyst" may predispose the adnexa to torsion and subsequent auto-amputation either in-utero or post-delivery. Many of these antenatally diagnosed cysts and even subsequent auto-amputations are completely asymptomatic, however, and do not compromise fertility assuming the contralateral adnexa are normal. Thus expectant management is appropriate for small (less than 4 cm), asymptomatic simple cysts and even suspected auto-amputated adnexa in an asymptomatic patient. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.
Fermi-Pasta-Ulam auto recurrence in the description of the electrical activity of the heart.
Novopashin, M A; Shmid, A V; Berezin, A A
2017-04-01
The authors proposed and mathematically described model of a new type of the Fermi-Pasta-Ulam recurrence (the FPU auto recurrence) and hypothesized an adequate description of the heart's electrical dynamics within the observed phenomenon. The dynamics of the FPU auto recurrence making appropriate electrical dynamics of the normal functioning of the heart in the form of an electrocardiogram (ECG) was obtained by a computer model study. The model solutions in the form of the FPU auto recurrence - ECG Fourier spectrum were evaluated for resistance to external disturbances in the form of random effects, as well as periodic perturbation at a frequency close to the heart beating rate of about 1Hz. In addition, in order to simulate the dynamics of myocardial infarction model, studied the effect of the surface area of the myocardium on the stability and shape of the auto recurrence - ECG spectrum. It has been found that the intense external disturbing periodic impacts at a frequency of about 1Hz lead to a sharp disturbance spectrum shape FPU auto recurrence - ECG structure. In addition, the decrease in the surface of the myocardium by 50% in the model led to the destruction of structures of the auto recurrence - ECG, which corresponds to the state of atrial myocardium. Research models have revealed a hypothetical basis of coronary heart disease in the form of increasing the energy of high-frequency harmonics spectrum of the auto recurrence by reducing the energy of low-frequency harmonic spectrum of the auto recurrence, which ultimately leads to a sharp decrease in myocardial contractility. In order to test the hypothesis has been studied more than 20,000 ECGs both healthy people and patients with cardiovascular disease. As a result of these studies, it was found that the dynamics of the electrical activity of normal functioning of the heart can be interpreted by the display of the detected by authors the FPU auto recurrence, and coronary heart disease is a violation of the energy ratio between the low and high frequency harmonics of the FPU auto recurrence Fourier spectrum equal to the ECG spectrum. Thus, the hypothesis has been confirmed. Copyright © 2017 Elsevier Ltd. All rights reserved.
[Value of specific 16S rDNA fragment of algae in diagnosis of drowning: an experiment with rabbits].
Li, Peng; Xu, Qu-Yi; Chen, Ling; Liu, Chao; Zhao, Jian; Wang, Yu-Zhong; Yu, Zheng-Liang; Hu, Sun-Lin; Wang, Hui-Jun
2015-08-01
To establish a method for amplifying specific 16S rDNA fragment of algae related with drowning and test its value in drowning diagnosis. Thirty-five rabbits were randomly divided into 3 the drowning group (n=15), postmortem water immersion group (n=15, subjected to air embolism before seawater immersion), and control group(n=5, with air embolism only). Twenty samples of the liver tissues from human corpses found in water were also used, including 14 diatom-positive and 6 diatom-negative samples identified by microwave digestion-vacuum filtration-automated scanning electron microscopy (MD-VF-Auto SEM). Seven known species of algae served as the control algae (Melosira sp, Nitzschia sp, Synedra sp, Navicula sp, Microcystis sp, Cyclotella meneghiniana, and Chlorella sp). The total DNA was extracted from the tissues and algae to amplify the specific fragment of algae followed by 8% polyacrylamide gelelectrophoresis and sliver-staining. In the drowning group, algae was detected in the lungs (100%), liver (86%), and kidney (86%); algae was detected in the lungs in 2 rabbits in the postmortem group (13%) and none in the control group. The positivity rates of algae were significantly higher in the drowning group than in the postmortem group (P<0.05). Of the 20 tissue samples from human corps found in water, 15 were found positive for algae, including sample that had been identified as diatom-negative by MD-VF-Auto SEM. All the 7 control algae samples yielded positive results in PCR. The PCR-based method has a high sensitivity in algae detection for drowning diagnosis and allows simultaneous detection of multiple algae species related with drowning.
A novel anti-theft security system for photovoltaic modules
NASA Astrophysics Data System (ADS)
Khan, Wasif Ali; Lim, Boon-Han; Lai, An-Chow; Chong, Kok-Keong
2017-04-01
Solar farms are considered as easy target for thieves because of insufficient protection measures. Existing anti-theft approaches are based on system level and are not very preventive and efficient because these can be bypassed with some technical knowledge. Additionally, it is difficult for security guards to tackle them as robbers come in a form of a gang equipped with heavy weapons. In this paper, a low power auto shut-off and non-destructive system is proposed for photovoltaic (PV) modules to achieve better level of security at module level. In proposed method, the power generation function of the PV module will be shut-off internally and cannot be re-activated by unauthorized personnel, in the case of theft. Hence, the PV module will not be functional even sold to new customers. The system comprises of a microcontroller, a low power position sensor, a controllable semiconductor switch and a wireless reactive-able system. The anti-theft system is developed to be laminated inside PV module and will be interconnected with solar cells so it becomes difficult for thieves to temper. The position of PV module is retrieved by position sensor and stored in a microcontroller as an initial reference value. Microcontroller uses this stored reference value to control power supply of PV module via power switch. The stored reference value can be altered using wireless circuitry by following authentication protocol. It makes the system non-destructive as anti-theft function can be reset again by authorized personnel, if it is recovered after theft or moved for maintenance purposes. The research component includes the design of a position sensing circuit, an auto shut-off circuit, a reactive-able wireless security protection algorithm and finally the integration of the multiple circuits.
Sirisena, Pdnn; Noordeen, Faseeha; Kurukulasuriya, Harithra; Romesh, Thanuja Alar; Fernando, LakKumar
2017-01-01
Dengue is one of the major hurdles to the public health in Sri Lanka, causing high morbidity and mortality. The present study focuses on the use of geographical information systems (GIS) to map and evaluate the spatial and temporal distribution of dengue in Sri Lanka from 2009 to 2014 and to elucidate the association of climatic factors with dengue incidence. Epidemiological, population and meteorological data were collected from the Epidemiology Unit, Department of Census and Statistics and the Department of Meteorology of Sri Lanka. Data were analyzed using SPSS (Version 20, 2011) and R studio (2012) and the maps were generated using Arc GIS 10.2. The dengue incidence showed a significant positive correlation with rainfall (p<0.0001). No positive correlation was observed between dengue incidence and temperature (p = 0.107) or humidity (p = 0.084). Rainfall prior to 2 and 5 months and a rise in the temperature prior to 9 months positively correlated with dengue incidence as based on the auto-correlation values. A rise in humidity prior to 1 month had a mild positive correlation with dengue incidence. However, a rise in humidity prior to 9 months had a significant negative correlation with dengue incidence based on the auto-correlation values. Remote sensing and GIS technologies give near real time utility of climatic data together with the past dengue incidence for the prediction of dengue outbreaks. In that regard, GIS will be applicable in outbreak predictions including prompt identification of locations with dengue incidence and forecasting future risks and thus direct control measures to minimize major outbreaks.
Serum DHCR24 Auto-antibody as a new Biomarker for Progression of Hepatitis C
Ezzikouri, Sayeh; Kimura, Kiminori; Sunagozaka, Hajime; Kaneko, Shuichi; Inoue, Kazuaki; Nishimura, Tomohiro; Hishima, Tsunekazu; Kohara, Michinori; Tsukiyama-Kohara, Kyoko
2015-01-01
Background New biomarkers are needed to identify the stage of hepatitis C virus (HCV)-infected diseases in order to reduce the mortality rates. Herein, we investigated whether serum 3β-hydroxysterol Δ24-reductase antibody (DHCR24 Ab) may serve as a prognostic marker for hepatitis C infection progression to hepatocellular carcinoma (HCC). Methods Serum DHCR24 Abs from 395 HCV-positive patients, including 133 chronic hepatitis (CHC), 85 liver cirrhosis (LCC), and 177 HCC (HCC-C) patients; 232 hepatitis B virus (HBV)-positive patients, including 103 chronic hepatitis (CHB), 56 liver cirrhosis (LCB), and 73 HCC (HCC-B) patients; and 24 healthy controls, were measured using enzyme-linked immunosorbent assay. Results The serum DHCR24 Ab levels were significantly higher in patients with CHC than in healthy controls, in LCC than in CHC, and in LCC than in HCC-C (P < 0.0001 for all). The concentration of serum DHCR24 Ab in HCC-B patients showed no significant difference compared to CHB and LCB patients (P = 0.1247). The DHCR24 Ab levels were significantly higher in early HCC-C than CHC or LCC patients and in late HCC-C compared to early HCC-C patients. The sensitivity of the DHCR24 Ab for HCC-C detection (70.6%) was higher than that of alpha-fetoprotein (AFP; 54.8%) and protein induced by vitamin K absence or antagonist-II (PIVKA-II; 42 · 5%). Moreover, DHCR24 was up-regulated in HCV-positive, but not HBV-positive tissues or HBV-negative, HCV-negative HCC specimens. Conclusions DHCR24 auto-antibody represents a potential noninvasive biomarker for HCV-related liver disease and may facilitate the diagnosis of PIVKA-II and AFP-negative HCC. PMID:26288822
Sirisena, PDNN; Noordeen, Faseeha; Kurukulasuriya, Harithra; Romesh, Thanuja ALAR; Fernando, LakKumar
2017-01-01
Dengue is one of the major hurdles to the public health in Sri Lanka, causing high morbidity and mortality. The present study focuses on the use of geographical information systems (GIS) to map and evaluate the spatial and temporal distribution of dengue in Sri Lanka from 2009 to 2014 and to elucidate the association of climatic factors with dengue incidence. Epidemiological, population and meteorological data were collected from the Epidemiology Unit, Department of Census and Statistics and the Department of Meteorology of Sri Lanka. Data were analyzed using SPSS (Version 20, 2011) and R studio (2012) and the maps were generated using Arc GIS 10.2. The dengue incidence showed a significant positive correlation with rainfall (p<0.0001). No positive correlation was observed between dengue incidence and temperature (p = 0.107) or humidity (p = 0.084). Rainfall prior to 2 and 5 months and a rise in the temperature prior to 9 months positively correlated with dengue incidence as based on the auto-correlation values. A rise in humidity prior to 1 month had a mild positive correlation with dengue incidence. However, a rise in humidity prior to 9 months had a significant negative correlation with dengue incidence based on the auto-correlation values. Remote sensing and GIS technologies give near real time utility of climatic data together with the past dengue incidence for the prediction of dengue outbreaks. In that regard, GIS will be applicable in outbreak predictions including prompt identification of locations with dengue incidence and forecasting future risks and thus direct control measures to minimize major outbreaks. PMID:28068339
High accuracy in short ISS missions
NASA Astrophysics Data System (ADS)
Rüeger, J. M.
1986-06-01
Traditionally Inertial Surveying Systems ( ISS) are used for missions of 30 km to 100 km length. Today, a new type of ISS application is emanating from an increased need for survey control densification in urban areas often in connection with land information systems or cadastral surveys. The accuracy requirements of urban surveys are usually high. The loss in accuracy caused by the coordinate transfer between IMU and ground marks is investigated and an offsetting system based on electronic tacheometers is proposed. An offsetting system based on a Hewlett-Packard HP 3820A electronic tacheometer has been tested in Sydney (Australia) in connection with a vehicle mounted LITTON Auto-Surveyor System II. On missions over 750 m ( 8 stations, 25 minutes duration, 3.5 minute ZUPT intervals, mean offset distances 9 metres) accuracies of 37 mm (one sigma) in position and 8 mm in elevation were achieved. Some improvements to the LITTON Auto-Surveyor System II are suggested which would improve the accuracies even further.
A high-efficiency electromechanical battery
NASA Astrophysics Data System (ADS)
Post, Richard F.; Fowler, T. K.; Post, Stephen F.
1993-03-01
In our society there is a growing need for efficient cost-effective means for storing electrical energy. The electric auto is a prime example. Storage systems for the electric utilities, and for wind or solar power, are other examples. While electrochemical cells could in principle supply these needs, the existing E-C batteries have well-known limitations. This article addresses an alternative, the electromechanical battery (EMB). An EMB is a modular unit consisting of an evacuated housing containing a fiber-composite rotor. The rotor is supported by magnetic bearings and contains an integrally mounted permanent magnet array. This article addresses design issues for EMBs with rotors made up of nested cylinders. Issues addressed include rotational stability, stress distributions, generator/motor power and efficiency, power conversion, and cost. It is concluded that the use of EMBs in electric autos could result in a fivefold reduction (relative to the IC engine) in the primary energy input required for urban driving, with a concomitant major positive impact on our economy and on air pollution.
Mannis, Gabriel N; Martin, Thomas G; Damon, Lloyd E; Andreadis, Charalambos; Olin, Rebecca L; Kong, Katherine A; Faham, Malek; Hwang, Jimmy; Ai, Weiyun Z; Gaensler, Karin M L; Sayre, Peter H; Wolf, Jeffrey L; Logan, Aaron C
2016-06-01
Since the incorporation of tyrosine kinase inhibitors into the treatment of Philadelphia chromosome-positive (Ph+) acute lymphoblastic leukemia (ALL), the notion that all patients with "high-risk" ALL uniformly require allogeneic (allo) hematopoietic cell transplantation (HCT) has received increasing scrutiny. Although multiple studies have shown superiority of alloHCT over autologous (auto) hematopoietic cell transplantation for high-risk patients, these findings may be explained, in part, by contamination of the peripheral blood progenitor cell (PBPC) leukapheresis product by residual leukemic cells in patients undergoing autoHCT. We retrospectively evaluated minimal residual disease (MRD) using next-generation sequencing (NGS) in the PBPC leukapheresis product of 32 ALL patients who underwent autoHCT. Twenty-eight patients (88%) had diagnostic samples with quantifiable immunoreceptor rearrangements to follow for MRD. Twelve (38%) patients had Ph+ B-ALL, 12 (38%) had Philadelphia chromosome-negative (Ph-) B-ALL, and 4 (14%) had T cell ALL. With a median follow-up of 41 months (range, 3 to 217), median relapse-free survival (RFS) and overall survival for the entire cohort were 3.2 and 4.2 years, respectively; at 5 years after transplantation, 42% of patients remain alive and relapse free. Using MRD detection at a threshold of ≥ 1 × 10(-6), median RFS for patients with detectable MRD was 6.5 months and was not reached for patients without detectable disease (P = .0005). In multivariate analysis, the only factor significantly associated with relapse was the presence of MRD ≥1 × 10(-6) (odds ratio, 23.8; confidence interval, 1.8 to 312.9; P = .0158). Our findings suggest that NGS for MRD detection can predict long-term RFS in patients undergoing autoHCT for high-risk ALL. Copyright © 2016 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
Doshi, T; Wilson, C; Paterson, C; Lamb, C; James, A; MacKenzie, K; Soraghan, J; Petropoulakis, L; Di Caterina, G; Grose, D
2017-01-01
To carry out statistical validation of a newly developed magnetic resonance imaging (MRI) auto-contouring software tool for gross tumour volume (GTV) delineation in head and neck tumours to assist in radiotherapy planning. Axial MRI baseline scans were obtained for 10 oropharyngeal and laryngeal cancer patients. GTV was present on 102 axial slices and auto-contoured using the modified fuzzy c-means clustering integrated with the level set method (FCLSM). Peer-reviewed (C-gold) manual contours were used as the reference standard to validate auto-contoured GTVs (C-auto) and mean manual contours (C-manual) from two expert clinicians (C1 and C2). Multiple geometric metrics, including the Dice similarity coefficient (DSC), were used for quantitative validation. A DSC≥0.7 was deemed acceptable. Inter- and intra-variabilities among the manual contours were also validated. The two-dimensional contours were then reconstructed in three dimensions for GTV volume calculation, comparison and three-dimensional visualisation. The mean DSC between C-gold and C-auto was 0.79. The mean DSC between C-gold and C-manual was 0.79 and that between C1 and C2 was 0.80. The average time for GTV auto-contouring per patient was 8 min (range 6-13 min; mean 45 s per axial slice) compared with 15 min (range 6-23 min; mean 88 s per axial slice) for C1. The average volume concordance between C-gold and C-auto volumes was 86.51% compared with 74.16% between C-gold and C-manual. The average volume concordance between C1 and C2 volumes was 86.82%. This newly designed MRI-based auto-contouring software tool shows initial acceptable results in GTV delineation of oropharyngeal and laryngeal tumours using FCLSM. This auto-contouring software tool may help reduce inter- and intra-variability and can assist clinical oncologists with time-consuming, complex radiotherapy planning. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Van Dalem, Annelien; Demeester, Simke; Balti, Eric V; Decochez, Katelijn; Weets, Ilse; Vandemeulebroucke, Evy; Van de Velde, Ursule; Walgraeve, An; Seret, Nicole; De Block, Christophe; Ruige, Johannes; Gillard, Pieter; Keymeulen, Bart; Pipeleers, Daniel G; Gorus, Frans K
2015-12-01
We examined whether measures of glycaemic variability (GV), assessed by continuous glucose monitoring (CGM) and self-monitoring of blood glucose (SMBG), can complement or replace measures of beta cell function and insulin action in detecting the progression of preclinical disease to type 1 diabetes. Twenty-two autoantibody-positive (autoAb(+)) first-degree relatives (FDRs) of patients with type 1 diabetes who were themselves at high 5-year risk (50%) for type 1 diabetes underwent CGM, a hyperglycaemic clamp test and OGTT, and were followed for up to 31 months. Clamp variables were used to estimate beta cell function (first-phase [AUC5-10 min] and second-phase [AUC120-150 min] C-peptide release) combined with insulin resistance (glucose disposal rate; M 120-150 min). Age-matched healthy volunteers (n = 20) and individuals with recent-onset type 1 diabetes (n = 9) served as control groups. In autoAb(+) FDRs, M 120-150 min below the 10th percentile (P10) of controls achieved 86% diagnostic efficiency in discriminating between normoglycaemic FDRs and individuals with (impending) dysglycaemia. M 120-150 min outperformed AUC5-10 min and AUC120-150 min C-peptide below P10 of controls, which were only 59-68% effective. Among GV variables, CGM above the reference range was better at detecting (impending) dysglycaemia than elevated SMBG (77-82% vs 73% efficiency). Combined CGM measures were equally efficient as M 120-150 min (86%). Daytime GV variables were inversely correlated with clamp variables, and more strongly with M 120-150 min than with AUC5-10 min or AUC120-150 min C-peptide. CGM-derived GV and the glucose disposal rate, reflecting both insulin secretion and action, outperformed SMBG and first- or second-phase AUC C-peptide in identifying FDRs with (impending) dysglycaemia or diabetes. Our results indicate the feasibility of developing minimally invasive CGM-based criteria for close metabolic monitoring and as outcome measures in trials.
Czerw, T; Labopin, M; Gorin, N-C; Giebel, S; Blaise, D; Dumas, P-Y; Foa, R; Attal, M; Schaap, N; Michallet, M; Bonmati, C; Veelken, H; Mohty, M
2014-07-01
Application of G-CSF in AML is controversial as leukemic blasts may express receptors interacting with the cytokine, which may stimulate leukemia growth. We retrospectively analyzed the impact of G-CSF use to accelerate neutrophil recovery after auto-SCT on outcome. Adults with AML in first CR autografted between 1994 and 2010 were included. Nine hundred and seventy two patients were treated with G-CSF after auto-SCT whereas 1121 were not. BM and PB were used as a source of stem cells in 454 (22%) and 1639 (78%) cases, respectively. The incidence of relapse at 5 years in the BM-auto-SCT group was 38% for patients receiving post-transplant G-CSF and 43% for those not treated with G-CSF, P=0.46. In the PB-auto-SCT cohort, respective probabilities were 48% and 49%, P=0.49. No impact of the use of G-CSF could be demonstrated with respect to the probability of leukemia-free survival: in the BM-auto-SCT group, 51% for G-CSF(+) and 48% for G-CSF(-), P=0.73; in PB-auto-SCT group, 42% for G-CSF(+) and 43% for G-CSF(-), P=0.83. Although G-CSF administration significantly shortened the neutropenic phase, no beneficial effect was observed with regard to non-relapse mortality. In patients with AML, the use of G-CSF after auto-SCT is not associated with increased risk of relapse irrespective of the source of stem cells used.
A comparison of the autonomy over tobacco scale and the Fagerström test for nicotine dependence.
Difranza, Joseph R; Savageau, Judith A; Wellman, Robert J
2012-07-01
The autonomy over tobacco scale (AUTOS) is a 12-item theory-based instrument used to measure tobacco dependence in smokers. It provides separate measures of three factors that make smoking cessation more difficult: withdrawal symptoms, psychological dependence, and cue-induced urges to use tobacco. We compared the internal reliability and concurrent validity of the AUTOS to those of the Fagerström test for nicotine dependence (FTND). Adult current smokers (n=422; 62% female; 86.8% white; mean age 33.3 years, SD=13.7; 57% daily smokers) completed an anonymous web-based survey that included the AUTOS, the FTND and 11 smoking-related behavioral measures. Cronbach's α was .94 for the AUTOS and α>.75 for each of the 3 subscales; α=.73 for the FTND. The AUTOS and its subscales correlated with all measures of concurrent validity (r=.70 between AUTOS & FTND). The AUTOS correlated better than the FTND with the Hooked on Nicotine Checklist, the longest period of abstinence, latency to wanting, percentage of time a person smokes because of momentary need, pleasure from smoking, days smoked per month, and concern about deprivation. The measures showed similar correlations with the latencies to craving and needing. The FTND correlated better with the duration of smoking and cigarettes smoked per day. Based on these results and those from prior studies, we conclude that the AUTOS offers researchers a valid and highly reliable, theory-based measure that is more versatile in its applications than the FTND. Copyright © 2012 Elsevier Ltd. All rights reserved.
Gravi- and photostimuli in moss protonema growth movements
NASA Astrophysics Data System (ADS)
Demkiv, O. T.; Kordyum, E. L.; Khorkavtsiv, Ya D.; Kardash, O. R.; Chaban, Ch. I.
Moss protonemal growth direction is controlled by at least three factors, photo-, gravi- and autotropism. It is possible to experimentally separate these factors and to control selectively their morphological appearance. In darkness protonema grow negatively gravitropically, and unilateral illumination initiated positive phototropism. Red light suppressed auto- and gravitropism, blue light suppressed only gravitropism. Green light allowed both gravi- and autotropism. The effect of light on gravitropism might involve changes in starch synthesis.
Gravi- and photostimuli in moss protonema growth movements.
Demkiv, O T; Kordyum, E L; Khorkavtsiv YaD; Kardash, O R; Chaban ChI
1998-01-01
Moss protonemal growth direction is controlled by at least three factors, photo-, gravi- and autotropism. It is possible to experimentally separate these factors and to control selectively their morphological appearance. In darkness protonema grow negatively gravitropically, and unilateral illumination initiated positive phototropism. Red light suppressed auto- and gravitropism, blue light suppressed only gravitropism. Green light allowed both gravi- and autotropism. The effect of light on gravitropism might involve changes in starch synthesis.
Dehoratius, Raphael J; Brent, Lawrence H; Curtis, Jeffrey R; Ellis, Lorie A; Tang, Kezhen L
2018-06-01
Patient perceptions of treatment success, including satisfaction/preference, may complement clinical efficacy assessments. Our objective was to evaluate satisfaction with subcutaneous golimumab and its auto-injector in patients with rheumatoid arthritis (RA) and an inadequate adalimumab/etanercept response. In the multicenter, assessor-blinded GO-SAVE study, 433 patients with active RA (28-joint Disease Activity Score incorporating erythrocyte sedimentation rate [DAS28-ESR] ≥ 3.6 and six or more swollen and six or more tender joints) despite methotrexate and past adalimumab/etanercept treatment received open-label subcutaneous golimumab 50 mg every 4 weeks (q4w) through week 12. Week 16 responders (DAS28-ESR improvement from baseline > 1.2 and score ≤ 3.2) continued therapy through week 52; nonresponders were randomized (1:2) to double-blind subcutaneous golimumab 50 mg q4w or intravenous golimumab 2 mg/kg [weeks 16, 20, every 8 weeks (q8w)]. Patients rated satisfaction with their injection experience on a 5-point scale (1 = very dissatisfied; 5 = very satisfied) at screening, week 8 (all enrolled patients), and week 44 (for patients continuing open-label subcutaneous golimumab 50 mg q4w). Discomfort, pain, stinging, burning, and redness related to injection were assessed (none, mild, moderate, severe). Similar proportions of patients (N = 433) had most recently received adalimumab (50.3%) or etanercept (49.7%) prior to golimumab. Overall satisfaction (somewhat/very) with the golimumab injection experience was reported by 84.4% of patients at week 8 versus 63.4% of patients who were satisfied with prior adalimumab/etanercept. Patients receiving open-label subcutaneous golimumab through week 44 (N = 75) reported much less discomfort (60.9%), redness (60.9%), pain (59.4%), stinging (67.2%), and burning (65.6%) with the golimumab injection than with their previous tumor necrosis factor antagonist medication injection. Most patients with RA receiving golimumab following adalimumab/etanercept inadequate response were satisfied with their overall golimumab experience, including its auto-injector versus their previous injection device. CLINICAL TRIALS.GOV: NCT01004432; EudraCT 2009-010582-23.
16 CFR 640.6 - Rules of construction.
Code of Federal Regulations, 2011 CFR
2011-01-01
... credit to finance the purchase of an automobile. If the auto dealer is the person to whom the loan obligation is initially payable, such as where the auto dealer is the original creditor under a retail installment sales contract, the auto dealer must provide the risk-based pricing notice to the consumer (or...
16 CFR 640.6 - Rules of construction.
Code of Federal Regulations, 2014 CFR
2014-01-01
... credit to finance the purchase of an automobile. If the auto dealer is the person to whom the loan obligation is initially payable, such as where the auto dealer is the original creditor under a retail installment sales contract, the auto dealer must provide the risk-based pricing notice to the consumer (or...
16 CFR 640.6 - Rules of construction.
Code of Federal Regulations, 2013 CFR
2013-01-01
... credit to finance the purchase of an automobile. If the auto dealer is the person to whom the loan obligation is initially payable, such as where the auto dealer is the original creditor under a retail installment sales contract, the auto dealer must provide the risk-based pricing notice to the consumer (or...
16 CFR 640.6 - Rules of construction.
Code of Federal Regulations, 2012 CFR
2012-01-01
... credit to finance the purchase of an automobile. If the auto dealer is the person to whom the loan obligation is initially payable, such as where the auto dealer is the original creditor under a retail installment sales contract, the auto dealer must provide the risk-based pricing notice to the consumer (or...
Cool-and Unusual-CAD Applications
ERIC Educational Resources Information Center
Calhoun, Ken
2004-01-01
This article describes several very useful applications of AutoCAD that may lie outside the normal scope of application. AutoCAD commands used in this article are based on AutoCAD 2000I. The author and his students used a Hewlett Packard 750C DesignJet plotter for plotting. (Contains 5 figures and 5 photos.)
Some Thermophysical Properties of Blood Components and Coolants for Frozen Blood Shipping Containers
1989-09-01
SP number by sending a DP reading. Subroutine : AutoControl Automatic control to set temperature. : Autodisplay Get ilL Thermocouple readings and...RETURN 133 AutoControl : Auto control Mode ON TIMER(ReportTime) GOSUB Autodisplay Update Screen in constant interval TIMER ON WHILE Success a 0 Turn off
Isakozawa, Shigeto; Fuse, Taishi; Amano, Junpei; Baba, Norio
2018-04-01
As alternatives to the diffractogram-based method in high-resolution transmission electron microscopy, a spot auto-focusing (AF) method and a spot auto-stigmation (AS) method are presented with a unique high-definition auto-correlation function (HD-ACF). The HD-ACF clearly resolves the ACF central peak region in small amorphous-thin-film images, reflecting the phase contrast transfer function. At a 300-k magnification for a 120-kV transmission electron microscope, the smallest areas used are 64 × 64 pixels (~3 nm2) for the AF and 256 × 256 pixels for the AS. A useful advantage of these methods is that the AF function has an allowable accuracy even for a low s/n (~1.0) image. A reference database on the defocus dependency of the HD-ACF by the pre-acquisition of through-focus amorphous-thin-film images must be prepared to use these methods. This can be very beneficial because the specimens are not limited to approximations of weak phase objects but can be extended to objects outside such approximations.
Conventional dual-cure versus self-adhesive resin cements in dentin bond integrity
da SILVA, Renata Andreza Talaveira; COUTINHO, Margareth; CARDOZO, Pedro Igor; da SILVA, Larissa Alves; ZORZATTO, José Roberto
2011-01-01
During post preparation, the root canal is exposed to the oral cavity, and endodontic treatment may fail because of coronal leakage, bacterial infection and sealing inability of the luting cement. Objective this study quantified the interfacial continuity produced with conventional dual-cure and self-adhesive resin cements in the cervical (C), medium (M) and apical (A) thirds of the root. Material and methods Forty single-rooted human teeth were restored using Reforpost # 01 conical glass-fiber posts and different materials (N=10 per group): group AC=Adper™ ScotchBond™ Multi-purpose Plus + AllCem; group ARC=Adper™ ScotchBond™ Multi-purpose Plus + RelyX ARC; group U100=RelyX U100; and group MXC=Maxcem Elite. After being kept in 100% humidity at 37ºC for 72 hours, the samples were sectioned parallel to their longitudinal axis and positive epoxy resin replicas were made. The scanning electron micrographs of each third section of the teeth were combined using Image Analyst software and measured with AutoCAD-2002. We obtained percentage values of the interfacial continuity. Results Interfacial continuity was similar in the apical, medium and cervical thirds of the roots within the groups (Friedman test, p>0.05). Comparison of the different cements in a same root third showed that interfacial continuity was lower in MXC (C=45.5%; M=48.5%; A=47.3%) than in AC (C=85.9%, M=81.8% and A=76.0%), ARC (C=83.8%, M=82.4% and A=75.0%) and U100 (C=84.1%, M=82.4% and A=77.3%) (Kruskal-Wallis test, p<0.05). Conclusions Allcem, Rely X ARC and U100 provide the best cementation; cementation was similar among root portions; in practical terms, U100 is the best resin because it combines good cementation and easy application and none of the cements provides complete interfacial continuity. PMID:21710099
Time-frequency approach to underdetermined blind source separation.
Xie, Shengli; Yang, Liu; Yang, Jun-Mei; Zhou, Guoxu; Xiang, Yong
2012-02-01
This paper presents a new time-frequency (TF) underdetermined blind source separation approach based on Wigner-Ville distribution (WVD) and Khatri-Rao product to separate N non-stationary sources from M(M <; N) mixtures. First, an improved method is proposed for estimating the mixing matrix, where the negative value of the auto WVD of the sources is fully considered. Then after extracting all the auto-term TF points, the auto WVD value of the sources at every auto-term TF point can be found out exactly with the proposed approach no matter how many active sources there are as long as N ≤ 2M-1. Further discussion about the extraction of auto-term TF points is made and finally the numerical simulation results are presented to show the superiority of the proposed algorithm by comparing it with the existing ones.
Hochdorn, Alexander; Faleiros, Vicente P.; Valerio, Paolo; Vitelli, Roberto
2018-01-01
Purpose: Understanding how transgender people, who committed criminal offenses and are detained in prison, produce a narrative representation of self within different prison contexts. More specifically, this study has been based on two sub-aims: On a paradigmatic level, it has been aimed at critically investigating how the discursive positioning among the Self and the Other might promote the internalization of positive and/or negative attitudes toward the self. On a pragmatic level, it intends to offer some suggestions for goals and strategies of psychological counseling with these inmates inside such highly institutionalized contexts. Method and Materials: In total, 23 in-depth interviews were conducted with transgender women detained in either female or male prison contexts in Italy and Brazil. The lexical, semantic, and semiotic structure of the transcribed interviews has been investigated by adopting the quali-quantitative software Iramuteq for performing statistical text-mining analysis. Frequency, correspondences, and distribution of the most representative utterances across the corpus of data have been accessed and critically analyzed. Results: The findings showed that transgender inmates in Brazil made repeated use of the adverb “not,” while the verb “exist” became the most representative word for the Italian sample. In Brazil, indeed, transgender women assumed masculine-driven behavior due to a common imprisonment with cis-gender men. On the contrary, transgender women in Italy are detained in protected sections, where they are allowed to wear female clothing and continue hormonal treatments. Surprisingly, transgender inmates in Italy suffered more violence in a female sector when compared to exclusively male jails. Conclusions: Transgender people represent a challenge for prison administration because it is not clear in which penitentiary context they should be detained. They should receive special attentions in order to face their special needs, which are radically different when compared to other typologies of inmates. Within penitentiary contexts, psychological counseling with transgender women should pay a special attention to the several psycho-social dimensions of this existential condition. In particular, psychological counselors should consider its inner complex articulation within different social, cultural and normative contexts. PMID:29387034
Hochdorn, Alexander; Faleiros, Vicente P; Valerio, Paolo; Vitelli, Roberto
2017-01-01
Purpose: Understanding how transgender people, who committed criminal offenses and are detained in prison, produce a narrative representation of self within different prison contexts. More specifically, this study has been based on two sub-aims: On a paradigmatic level, it has been aimed at critically investigating how the discursive positioning among the Self and the Other might promote the internalization of positive and/or negative attitudes toward the self. On a pragmatic level, it intends to offer some suggestions for goals and strategies of psychological counseling with these inmates inside such highly institutionalized contexts. Method and Materials: In total, 23 in-depth interviews were conducted with transgender women detained in either female or male prison contexts in Italy and Brazil. The lexical, semantic, and semiotic structure of the transcribed interviews has been investigated by adopting the quali-quantitative software Iramuteq for performing statistical text-mining analysis. Frequency, correspondences, and distribution of the most representative utterances across the corpus of data have been accessed and critically analyzed. Results: The findings showed that transgender inmates in Brazil made repeated use of the adverb "not," while the verb "exist" became the most representative word for the Italian sample. In Brazil, indeed, transgender women assumed masculine-driven behavior due to a common imprisonment with cis-gender men. On the contrary, transgender women in Italy are detained in protected sections, where they are allowed to wear female clothing and continue hormonal treatments. Surprisingly, transgender inmates in Italy suffered more violence in a female sector when compared to exclusively male jails. Conclusions: Transgender people represent a challenge for prison administration because it is not clear in which penitentiary context they should be detained. They should receive special attentions in order to face their special needs, which are radically different when compared to other typologies of inmates. Within penitentiary contexts, psychological counseling with transgender women should pay a special attention to the several psycho-social dimensions of this existential condition. In particular, psychological counselors should consider its inner complex articulation within different social, cultural and normative contexts.
Deepak, Vemula; Challa, Ramasubba Reddy; Kamatham, Rekhalakshmi; Nuvvula, Sivakumar
2017-01-01
Background: Pain in the dental operatory can have a profound effect on the behavior of children. Aim: The aim of this study is to evaluate the pain perception while administering local infiltration, in children undergoing dental extractions, using a new auto-controlled injection system. Materials and Methods: Children in the age range of 6–10 years with teeth indicated for extraction were recruited and allocated to either Group I, computer-controlled injection system (auto system with special cartridge and compatible disposable 30-gauge, 10 mm needles), or Group II, traditional system (30-gauge, 10 mm needle and disposable traditional syringe). Local infiltration was administered and extraction performed after 3 min. The time of administration (TOA) of infiltrate was noted whereas anxiety and pain in both groups were assessed using the Modified Child Dental Anxiety Faces Scale simplified (MCDAS(f)), pulse rate, Faces Pain Scale-Revised (FPS-R), and Face, Legs, Activity, Cry, Consolability (FLACC) Scale. Results: The TOA was high in computer group, compared to the traditional system (P < 0.001***); however, anxiety and pain were significantly less in computer group as reported in MCDAS(f), pulse rate, FPS-R, and FLACC (P < 0.001***). Conclusions: Computer system created a positive and comfortable experience for the child, as well as the practitioner. The possibility of using buccal infiltration instead of inferior alveolar nerve block in children below 10 years was also demonstrated. PMID:28663636
Drought Patterns Forecasting using an Auto-Regressive Logistic Model
NASA Astrophysics Data System (ADS)
del Jesus, M.; Sheffield, J.; Méndez Incera, F. J.; Losada, I. J.; Espejo, A.
2014-12-01
Drought is characterized by a water deficit that may manifest across a large range of spatial and temporal scales. Drought may create important socio-economic consequences, many times of catastrophic dimensions. A quantifiable definition of drought is elusive because depending on its impacts, consequences and generation mechanism, different water deficit periods may be identified as a drought by virtue of some definitions but not by others. Droughts are linked to the water cycle and, although a climate change signal may not have emerged yet, they are also intimately linked to climate.In this work we develop an auto-regressive logistic model for drought prediction at different temporal scales that makes use of a spatially explicit framework. Our model allows to include covariates, continuous or categorical, to improve the performance of the auto-regressive component.Our approach makes use of dimensionality reduction (principal component analysis) and classification techniques (K-Means and maximum dissimilarity) to simplify the representation of complex climatic patterns, such as sea surface temperature (SST) and sea level pressure (SLP), while including information on their spatial structure, i.e. considering their spatial patterns. This procedure allows us to include in the analysis multivariate representation of complex climatic phenomena, as the El Niño-Southern Oscillation. We also explore the impact of other climate-related variables such as sun spots. The model allows to quantify the uncertainty of the forecasts and can be easily adapted to make predictions under future climatic scenarios. The framework herein presented may be extended to other applications such as flash flood analysis, or risk assessment of natural hazards.
Ohlsén, L; Jungner, I; Peterson, H E
2014-05-22
This paper presents the history of data system development steps (1964 - 1986) for the clinical analyzers AutoChemist®, and its successor AutoChemist PRISMA® (PRogrammable Individually Selective Modular Analyzer). The paper also partly recounts the history of development steps of the minicomputer PDP 8 from Digital Equipment. The first PDP 8 had 4 core memory boards of 1 K each and was large as a typical oven baking sheet and about 10 years later, PDP 8 was a "one chip microcomputer" with a 32 K memory chip. The fast developments of PDP 8 come to have a strong influence on the development of the data system for AutoChemist. Five major releases of the software were made during this period (1-5 MIACH). The most important aims were not only to calculate the results, but also be able to monitor their quality and automatically manage the orders, store the results in digital form for later statistical analysis and distribute the results to the physician in charge of the patient using thesame computer as the analyzer. Another result of the data system was the ability to customize AutoChemist to handle sample identification by using bar codes and the presentation of results to different types of laboratories. Digital Equipment launched the PDP 8 just as a new minicomputer was desperately needed. No other known alternatives were available at the time. This was to become a key success factor for AutoChemist. That the AutoChemist with such a high capacity required a computer for data collection was obvious already in the early 1960s. That computer development would be so rapid and that one would be able to accomplish so much with a data system was even suspicious at the time. In total, 75; AutoChemist (31) and PRISMA (44) were delivered Worldwide. The last PRISMA was delivered in 1987 to the Veteran Hospital Houston, TX USA.
Evaluation of a commercial automatic treatment planning system for prostate cancers.
Nawa, Kanabu; Haga, Akihiro; Nomoto, Akihiro; Sarmiento, Raniel A; Shiraishi, Kenshiro; Yamashita, Hideomi; Nakagawa, Keiichi
2017-01-01
Recent developments in Radiation Oncology treatment planning have led to the development of software packages that facilitate automated intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) planning. Such solutions include site-specific modules, plan library methods, and algorithm-based methods. In this study, the plan quality for prostate cancer generated by the Auto-Planning module of the Pinnacle 3 radiation therapy treatment planning system (v9.10, Fitchburg, WI) is retrospectively evaluated. The Auto-Planning module of Pinnacle 3 uses a progressive optimization algorithm. Twenty-three prostate cancer cases, which had previously been planned and treated without lymph node irradiation, were replanned using the Auto-Planning module. Dose distributions were statistically compared with those of manual planning by the paired t-test at 5% significance level. Auto-Planning was performed without any manual intervention. Planning target volume (PTV) dose and dose to rectum were comparable between Auto-Planning and manual planning. The former, however, significantly reduced the dose to the bladder and femurs. Regression analysis was performed to examine the correlation between volume overlap between bladder and PTV divided by the total bladder volume and resultant V70. The findings showed that manual planning typically exhibits a logistic way for dose constraint, whereas Auto-Planning shows a more linear tendency. By calculating the Akaike information criterion (AIC) to validate the statistical model, a reduction of interoperator variation in Auto-Planning was shown. We showed that, for prostate cancer, the Auto-Planning module provided plans that are better than or comparable with those of manual planning. By comparing our results with those previously reported for head and neck cancer treatment, we recommend the homogeneous plan quality generated by the Auto-Planning module, which exhibits less dependence on anatomic complexity. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Boos, Anja M; Loew, Johanna S; Deschler, Gloria; Arkudas, Andreas; Bleiziffer, Oliver; Gulle, Heinz; Dragu, Adrian; Kneser, Ulrich; Horch, Raymund E; Beier, Justus P
2011-01-01
Abstract Bone tissue engineering approaches increasingly focus on the use of mesenchymal stem cells (MSC). In most animal transplantation models MSC are isolated and expanded before auto cell transplantation which might be critical for clinical application in the future. Hence this study compares the potential of directly auto-transplanted versus in vitro expanded MSC with or without bone morphogenetic protein-2 (BMP-2) to induce bone formation in a large volume ceramic bone substitute in the sheep model. MSC were isolated from bone marrow aspirates and directly auto-transplanted or expanded in vitro and characterized using fluorescence activated cell sorting (FACS) and RT-PCR analysis before subcutaneous implantation in combination with BMP-2 and β-tricalcium phosphate/hydroxyapatite (β-TCP/HA) granules. Constructs were explanted after 1 to 12 weeks followed by histological and RT-PCR evaluation. Sheep MSC were CD29+, CD44+ and CD166+ after selection by Ficoll gradient centrifugation, while directly auto-transplanted MSC-populations expressed CD29 and CD166 at lower levels. Both, directly auto-transplanted and expanded MSC, were constantly proliferating and had a decreasing apoptosis over time in vivo. Directly auto-transplanted MSC led to de novo bone formation in a heterotopic sheep model using a β-TCP/HA matrix comparable to the application of 60 μg/ml BMP-2 only or implantation of expanded MSC. Bone matrix proteins were up-regulated in constructs following direct auto-transplantation and in expanded MSC as well as in BMP-2 constructs. Up-regulation was detected using immunohistology methods and RT-PCR. Dense vascularization was demonstrated by CD31 immunohistology staining in all three groups. Ectopic bone could be generated using directly auto-transplanted or expanded MSC with β-TCP/HA granules alone. Hence BMP-2 stimulation might become dispensable in the future, thus providing an attractive, clinically feasible approach to bone tissue engineering. PMID:20636333
Zając-Spychała, O; Wachowiak, J; Pieczonka, A; Siewiera, K; Frączkiewicz, J; Kałwak, K; Gorczyńska, E; Chybicka, A; Czyżewski, K; Jachna-Sawicka, K; Wysocki, M; Klepacka, J; Goździk, J; Zaucha-Prażmo, A; Kowalczyk, J R; Styczyński, J
2016-10-01
Infectious complications are a significant cause of hematopoietic stem cell transplantation (HSCT) failure, especially allogeneic HSCT (allo-HSCT) because of delayed immune reconstitution and graft-versus-host disease (GVHD) occurrence. Identifying the factors responsible for bacterial infections (BI) in patients undergoing HSCT will provide much more effective empirical antimicrobial treatment in this group of patients. The aim of this study was to evaluate the epidemiology and profile of BI in patients after HSCT in 5 centers of the Polish Pediatric Group for Hematopoietic Stem Cell Transplantation in 2012-2013. In 308 HSCT recipients, we retrospectively analyzed 273 episodes of BI in 113 (36.7%) children aged 0.02-22 years (median age: 7 years), 92 after allo-HSCT and 22 after autologous HSCT (auto-HSCT). We assessed incidence of BI in different HSCT types by calculating the Index of Bacterial Infection (IBI) as a ratio of patients with at least 1 BI to all patients who underwent this type of HSCT in the analyzed period. We assessed the profile of BI with particular emphasis on multidrug-resistant organisms, and impact of underlying disease and of graft-versus-host disease on BI episodes. In the studied group, 273 episodes of BI were diagnosed, including 237 episodes after allo-HSCT and 36 after auto-HSCT. Among allo-HSCT recipients diagnosed with at least 1 BI, the IBI was 0.4 (matched sibling donor-HSCT 0.3; matched donor-HSCT 0.4; mismatched unrelated donor [MMUD]-HSCT 0.8; P = 0.027) and after auto-HSCT 0.3 per 1 transplanted patient. In patient after allo-HSCT because of myelo- or lymphoproliferative diseases and bone marrow failures, the major cause of infections was Enterobacteriaceae, while gram-positive bacteria predominated in the group with primary immunodeficiencies. In all patients after auto-HSCT, the dominant pathogen of BI were Enterobacteriaceae (P = 0.011). Time from each type of HSCT to infection caused by different pathogens did not differ significantly. The risk of BI does not depend on the underlying disease, but only on HSCT donor type and is the highest after MMUD-HSCT procedure. The profile of BI depends on the underlying disease and HSCT donor type, but does not depend on the occurrence of acute GVHD. Gram-negative bacteria predominated in patients with myelo- and lymphoproliferative diseases, while in patients with primary immunodeficiencies gram-positive strains were predominant. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
New auto-tuning technique for the hydrogen maser
NASA Technical Reports Server (NTRS)
Sydnor, R. L.; Maleki, L.
1983-01-01
Auto-tuning of the maser cavity compensates for cavity pulling effect, and other sources of contribution to the long term frequency drift. Schemes previously proposed for the maser cavity auto-tuning can have adverse effects on the performance of the maser. A new scheme is proposed based on the phase relationship between the electric and the magnetic fields inside the cavity. This technique has the desired feature of auto-tuning the cavity with a very high sensitivity and without disturbing the maser performance. Some approaches for the implementation of this scheme and possible areas of difficulty are examined.
Sheikh, Aziz; Simons, F Estelle R; Barbour, Victoria; Worth, Allison
2012-08-15
Anaphylaxis is a serious hypersensitivity reaction that is rapid in onset and may cause death. Adrenaline (epinephrine) auto-injectors are recommended as the initial, potentially life-saving treatment of choice for anaphylaxis in the community, but they are not universally available and have limitations in their use. To assess the effectiveness of adrenaline (epinephrine) auto-injectors in relieving respiratory, cardiovascular, and other symptoms during episodes of anaphylaxis that occur in the community. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2012, Issue 1), MEDLINE (Ovid SP) (1950 to January 2012), EMBASE (Ovid SP) (1980 to January 2012 ), CINAHL (EBSCO host) (1982 to January 2012 ), AMED (EBSCO host) (1985 to January 2012 ), LILACS, (BIREME) (1980 to January 2012 ), ISI Web of Science (1950 to January 2012 ). We adapted our search terms for other databases. We also searched websites listing on-going trials: the World Health Organization International Clinical Trials Registry Platform, the UK Clinical Research Network Study Portfolio, and the meta Register of Controlled Trials; and contacted pharmaceutical companies who manufacture adrenaline auto-injectors in an attempt to locate unpublished material. Randomized and quasi-randomized controlled trials comparing auto-injector administration of adrenaline with any control including no intervention, placebo, or other adrenergic agonists were eligible for inclusion. Two authors independently assessed articles for inclusion. None of the 1328 studies that were identified satisfied the inclusion criteria. Based on this review, we cannot make any new recommendations on the effectiveness of adrenaline auto-injectors for the treatment of anaphylaxis. Although randomized, double-blind, placebo-controlled clinical trials of high methodological quality are necessary to define the true extent of benefits from the administration of adrenaline in anaphylaxis via an auto-injector, such trials are unlikely to be performed in individuals experiencing anaphylaxis because of ethical concerns associated with randomization to placebo. There is, however, a need to consider trials in which, for example, auto-injectors of different doses of adrenaline and differing devices are compared in order to provide greater clarity on the dose and device of choice. Such trials would be practically challenging to conduct. In the absence of appropriate trials, we recommend that adrenaline administration by auto-injector should still be regarded as the most effective first-line treatment for the management of anaphylaxis in the community. In countries where auto-injectors are not commonly used, it may be possible to conduct trials to compare administration of adrenaline via auto-injector with adrenaline administered by syringe and ampoule, or comparing the effectiveness of two different types of auto-injector.
High resolution optical shaft encoder for motor speed control based on an optical disk pick-up
NASA Astrophysics Data System (ADS)
Yeh, Wei-Hung; Bletscher, Warren; Mansuripur, M.
1998-08-01
Using a three-beam optical pick-up from a compact disk player and a flexible, shaft-mounted diffraction grating, we obtain information about the rotation speed and angular position of the motor's spindle. This information may be used for feedback to the motor for smooth operation. Due to the small size of the focused spot and the built-in auto-focus mechanism of the optical head, the proposed encoder can achieve submicrometer resolution. With high resolution, reliable operation, and low-cost elements, the proposed method is suitable for rotary and linear motion control where accurate positioning of an object is required.
NASA Astrophysics Data System (ADS)
Alshakova, E. L.
2017-01-01
The program in the AutoLISP language allows automatically to form parametrical drawings during the work in the AutoCAD software product. Students study development of programs on AutoLISP language with the use of the methodical complex containing methodical instructions in which real examples of creation of images and drawings are realized. Methodical instructions contain reference information necessary for the performance of the offered tasks. The method of step-by-step development of the program is the basis for training in programming on AutoLISP language: the program draws elements of the drawing of a detail by means of definitely created function which values of arguments register in that sequence in which AutoCAD gives out inquiries when performing the corresponding command in the editor. The process of the program design is reduced to the process of step-by-step formation of functions and sequence of their calls. The author considers the development of the AutoLISP program for the creation of parametrical drawings of details, the defined design, the user enters the dimensions of elements of details. These programs generate variants of tasks of the graphic works performed in educational process of "Engineering graphics", "Engineering and computer graphics" disciplines. Individual tasks allow to develop at students skills of independent work in reading and creation of drawings, as well as 3D modeling.
Psychometric properties of the Autonomy over Tobacco Scale in German.
Wellman, R J; Di Franza, J R; Morgenstern, M; Hanewinkel, R; Isensee, B; Sabiston, C M
2012-01-01
We investigated the psychometric properties of a German translation of the 12-item Autonomy over Tobacco Scale (AUTOS) among 1,195 eighth-grade students. Data for this study were collected as part of the fourth wave of data collection of the Smokefree Class Competition intervention in the Saxony-Anhalt region of Germany. Students from the control arm of the Smokefree Class Competition study who indicated that they had ever smoked 'at least a few puffs' on a cigarette were classified as ever-smokers. They self-completed questionnaires distributed by teachers. AUTOS scores ranged from 0 to 36 with a distribution highly skewed toward lower-response categories. Inter-item correlations ranged from 0.65 to 0.89 (mean = 0.79, SD = 0.06). Composite reliability for the AUTOS was high (Ω = 0.96) and 3 lower-order factors were also reliable (withdrawal: 0.89, psychological dependence: 0.91, cue-induced cravings: 0.87). Concurrent validity was supported by strong relationships between the AUTOS and both lifetime cigarette consumption and current smoking frequency. Youths were 18 times more likely to be current smokers (95% CI = 11.9-27.2, p < 0.001) if they endorsed any AUTOS item. The German AUTOS is reliable and valid, and the results are consistent with the English AUTOS for use with adolescents. Copyright © 2011 S. Karger AG, Basel.
Autoantibody Signaling in Pemphigus Vulgaris: Development of an Integrated Model
Sajda, Thomas; Sinha, Animesh A.
2018-01-01
Pemphigus vulgaris (PV) is an autoimmune skin blistering disease effecting both cutaneous and mucosal epithelia. Blister formation in PV is known to result from the binding of autoantibodies (autoAbs) to keratinocyte antigens. The primary antigenic targets of pathogenic autoAbs are known to be desmoglein 3, and to a lesser extent, desmoglein 1, cadherin family proteins that partially comprise the desmosome, a protein structure responsible for maintaining cell adhesion, although additional autoAbs, whose role in blister formation is still unclear, are also known to be present in PV patients. Nevertheless, there remain large gaps in knowledge concerning the precise mechanisms through which autoAb binding induces blister formation. Consequently, the primary therapeutic interventions for PV focus on systemic immunosuppression, whose side effects represent a significant health risk to patients. In an effort to identify novel, disease-specific therapeutic targets, a multitude of studies attempting to elucidate the pathogenic mechanisms downstream of autoAb binding, have led to significant advancements in the understanding of autoAb-mediated blister formation. Despite this enhanced characterization of disease processes, a satisfactory explanation of autoAb-induced acantholysis still does not exist. Here, we carefully review the literature investigating the pathogenic disease mechanisms in PV and, taking into account the full scope of results from these studies, provide a novel, comprehensive theory of blister formation in PV. PMID:29755451
Mawatari, M; Higo, T; Tsutsumi, Y; Shigematsu, M; Hotokebuchi, T
2006-08-01
To evaluate the effectiveness of autologous fibrin tissue adhesive (auto-FTA) in reducing blood loss during cementless total hip arthroplasty (THA). From September 2000 to August 2001, 100 patients who predonated 400 ml of autologous blood were randomised to undergo either standard treatment with auto-FTA (auto-FTA group) or standard treatment alone (control group). The volume of postoperative blood loss and the decrease in haemoglobin level were measured. All patients were followed up for 3 years to evaluate the rate of bone ingrowth and heterotopic ossification. The mean postoperative blood loss was 580 ml (standard deviation [SD], 240 ml) in the auto-FTA group and 810 ml (SD, 341 ml) in the control group; the difference was significant (230 ml, p<0.001). The decrease in haemoglobin concentration was 17 g/l (SD, 11 g/l) in the auto-FTA group and 22 g/l (SD, 12 g/l) in the control group. The difference was significant (5 g/l, p=0.03). The percentage of total blood loss of >1200 ml in any single patient was significantly lower in the auto-FTA group (4%) than in the control group (20%) [p=0.01]. Auto-FTA is a safe and effective means of reducing perioperative blood loss in THA.
Frew, A J
2011-01-01
Anaphylaxis is a systemic allergic reaction that often involves respiratory symptoms and cardiovascular collapse, which are potentially life-threatening if not treated promptly with intramuscular adrenaline. Owing to the unpredictable nature of anaphylaxis and accidental exposure to allergens (such as peanuts and shellfish), patients should be prescribed intramuscular adrenaline auto-injectors and carry these with them at all times. Patients also need to be able to use their auto-injectors correctly while under high stress, when an anaphylactic attack occurs. Despite this, an alarming number of patients fail to carry their auto-injectors and many patients, carers of children with known anaphylaxis and healthcare professionals do not know how to use the device correctly, despite having had training. Currently available auto-injector devices have various limitations that may impede their use in the management of anaphylaxis. There is also a lack of validated assessment criteria and regulatory requirements for new devices. This review describes the different delivery systems used in currently available auto-injectors and discusses the key barriers to the use of adrenaline auto-injectors, with the goal of identifying the 'ideal' features/characteristics of such devices in the emergency treatment of anaphylaxis that will ensure ease of use, portability and accurate delivery of a life-saving drug. © 2010 John Wiley & Sons A/S.
12 CFR 222.73 - Content, form, and timing of risk-based pricing notices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... financing the purchase of an automobile from an auto dealer or other party that is not affiliated with the...)(4), as applicable; or (ii) Arranges to have the auto dealer or other party provide a notice... maintains reasonable policies and procedures to verify that the auto dealer or other party provides such...
Auto Trade Policy and the Press: Auto Elite as a Source of the Media Agenda.
ERIC Educational Resources Information Center
Chang, Kuang-Kuo
1999-01-01
Contributes to scholarship on agenda setting and news reporting of international-trade issues. Uses content analysis to show that the auto elite set the agenda for the "New York Times" and the "Detroit News." Shows that the "Detroit News" was more likely than the "New York Times" to be more biased,…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-08
... of Anthracite Capital, Inc., Auto Data Network Inc., Avenue Group, Inc., Ckrush, Inc., Clickable... securities of Auto Data Network Inc. because it has not filed any periodic reports since the period ended... accurate information concerning the securities of Avenue Group, Inc. because it has not filed any periodic...
46 CFR 28.875 - Radar, depth sounding, and auto-pilot.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 1 2011-10-01 2011-10-01 false Radar, depth sounding, and auto-pilot. 28.875 Section 28... COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.875 Radar, depth sounding, and auto-pilot. (a) Each vessel must be fitted with a general marine radar system for surface navigation with a radar...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-10
... Proposed Rule Change The Exchange proposes to adopt changes to its crossing mechanisms to adopt an auto... proposal is to add step-up-and-match functionality (the ``auto-match feature'') to both mechanisms for an...-side order specifies the auction start price. With the auto-match feature, the contra-side order will...
My Story in a Profession of Stories: Auto Ethnography-- An Empowering Methodology for Educators
ERIC Educational Resources Information Center
Dyson, Michael
2007-01-01
This paper highlights a distinctive way to research and present issues within education using metaphor and the qualitative narrative methodology known as auto ethnography. Auto ethnographic writing links the personal to the cultural and is recognised as a methodology that combines the method with the writing of the text, which in turn explicates…
46 CFR 167.65-35 - Use of auto pilot.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Use of auto pilot. 167.65-35 Section 167.65-35 Shipping... Special Operating Requirements § 167.65-35 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used in— (a) Areas of high traffic density; (b) Conditions of restricted...
Redacting with Confidence: How to Safely Publish Sanitized Reports Converted from Word to PDF
2006-02-02
select Insert->Picture-> Autoshapes from the top menu bar (this opens the AutoShapes toolbar). Select the rectangle from the Autoshapes toolbar as in... AutoShape from the menu as in Figure 6 (this opens the Format AutoShape dialog box), select the Size tab, enter the desired height and width of the
Nonlinear System Identification for Aeroelastic Systems with Application to Experimental Data
NASA Technical Reports Server (NTRS)
Kukreja, Sunil L.
2008-01-01
Representation and identification of a nonlinear aeroelastic pitch-plunge system as a model of the Nonlinear AutoRegressive, Moving Average eXogenous (NARMAX) class is considered. A nonlinear difference equation describing this aircraft model is derived theoretically and shown to be of the NARMAX form. Identification methods for NARMAX models are applied to aeroelastic dynamics and its properties demonstrated via continuous-time simulations of experimental conditions. Simulation results show that (1) the outputs of the NARMAX model closely match those generated using continuous-time methods, and (2) NARMAX identification methods applied to aeroelastic dynamics provide accurate discrete-time parameter estimates. Application of NARMAX identification to experimental pitch-plunge dynamics data gives a high percent fit for cross-validated data.
Hamerlynck, Erik P; Scott, Russell L; Susan Moran, M; Schwander, Andrea M; Connor, Erin; Huxman, Travis E
2011-01-01
It is not clear if tree canopies in savanna ecosystems exert positive or negative effects on soil moisture, and how these might affect understory plant carbon balance. To address this, we quantified rooting-zone volumetric soil moisture (θ(25 cm)), plant size, leaf-level and whole-plant gas exchange of the bunchgrass, bush muhly (Muhlenbergia porteri), growing under and between mesquite (Prosopis velutina) in a southwestern US savanna. Across two contrasting monsoon seasons, bare soil θ(25 cm) was 1.0-2.5% lower in understory than in the intercanopy, and was consistently higher than in soils under grasses, where θ(25 cm) was similar between locations. Understory plants had smaller canopy areas and volumes with larger basal diameters than intercanopy plants. During an above-average monsoon, intercanopy and understory plants had similar seasonal light-saturated leaf-level photosynthesis (A(net-sat)), stomatal conductance (g(s-sat)), and whole-plant aboveground respiration (R(auto)), but with higher whole-plant photosynthesis (GEP(plant)) and transpiration (T(plant)) in intercanopy plants. During a below-average monsoon, intercanopy plants had higher diurnally integrated GEP(plant), R(auto), and T(plant). These findings showed little evidence of strong, direct positive canopy effects to soil moisture and attendant plant performance. Rather, it seems understory conditions foster competitive dominance by drought-tolerant species, and that positive and negative canopy effects on soil moisture and community and ecosystem processes depends on a suite of interacting biotic and abiotic factors.
NASA Astrophysics Data System (ADS)
Martin, Spencer; Brophy, Mark; Palma, David; Louie, Alexander V.; Yu, Edward; Yaremko, Brian; Ahmad, Belal; Barron, John L.; Beauchemin, Steven S.; Rodrigues, George; Gaede, Stewart
2015-02-01
This work aims to propose and validate a framework for tumour volume auto-segmentation based on ground-truth estimates derived from multi-physician input contours to expedite 4D-CT based lung tumour volume delineation. 4D-CT datasets of ten non-small cell lung cancer (NSCLC) patients were manually segmented by 6 physicians. Multi-expert ground truth (GT) estimates were constructed using the STAPLE algorithm for the gross tumour volume (GTV) on all respiratory phases. Next, using a deformable model-based method, multi-expert GT on each individual phase of the 4D-CT dataset was propagated to all other phases providing auto-segmented GTVs and motion encompassing internal gross target volumes (IGTVs) based on GT estimates (STAPLE) from each respiratory phase of the 4D-CT dataset. Accuracy assessment of auto-segmentation employed graph cuts for 3D-shape reconstruction and point-set registration-based analysis yielding volumetric and distance-based measures. STAPLE-based auto-segmented GTV accuracy ranged from (81.51 ± 1.92) to (97.27 ± 0.28)% volumetric overlap of the estimated ground truth. IGTV auto-segmentation showed significantly improved accuracies with reduced variance for all patients ranging from 90.87 to 98.57% volumetric overlap of the ground truth volume. Additional metrics supported these observations with statistical significance. Accuracy of auto-segmentation was shown to be largely independent of selection of the initial propagation phase. IGTV construction based on auto-segmented GTVs within the 4D-CT dataset provided accurate and reliable target volumes compared to manual segmentation-based GT estimates. While inter-/intra-observer effects were largely mitigated, the proposed segmentation workflow is more complex than that of current clinical practice and requires further development.
Martin, Spencer; Brophy, Mark; Palma, David; Louie, Alexander V; Yu, Edward; Yaremko, Brian; Ahmad, Belal; Barron, John L; Beauchemin, Steven S; Rodrigues, George; Gaede, Stewart
2015-02-21
This work aims to propose and validate a framework for tumour volume auto-segmentation based on ground-truth estimates derived from multi-physician input contours to expedite 4D-CT based lung tumour volume delineation. 4D-CT datasets of ten non-small cell lung cancer (NSCLC) patients were manually segmented by 6 physicians. Multi-expert ground truth (GT) estimates were constructed using the STAPLE algorithm for the gross tumour volume (GTV) on all respiratory phases. Next, using a deformable model-based method, multi-expert GT on each individual phase of the 4D-CT dataset was propagated to all other phases providing auto-segmented GTVs and motion encompassing internal gross target volumes (IGTVs) based on GT estimates (STAPLE) from each respiratory phase of the 4D-CT dataset. Accuracy assessment of auto-segmentation employed graph cuts for 3D-shape reconstruction and point-set registration-based analysis yielding volumetric and distance-based measures. STAPLE-based auto-segmented GTV accuracy ranged from (81.51 ± 1.92) to (97.27 ± 0.28)% volumetric overlap of the estimated ground truth. IGTV auto-segmentation showed significantly improved accuracies with reduced variance for all patients ranging from 90.87 to 98.57% volumetric overlap of the ground truth volume. Additional metrics supported these observations with statistical significance. Accuracy of auto-segmentation was shown to be largely independent of selection of the initial propagation phase. IGTV construction based on auto-segmented GTVs within the 4D-CT dataset provided accurate and reliable target volumes compared to manual segmentation-based GT estimates. While inter-/intra-observer effects were largely mitigated, the proposed segmentation workflow is more complex than that of current clinical practice and requires further development.
Outpatient Utilization by Infants Auto-assigned to Medicaid Managed Care Plans
Cohn, Lisa M.; Clark, Sarah J.
2013-01-01
To test the hypothesis that infants auto-assigned to a Medicaid managed care plan would have lower primary care and higher emergency department (ED) utilization compared to infants with a chosen plan. Retrospective cohort study. Medicaid administrative data were used to identify all children 0–3 months of age at enrollment in Michigan Medicaid managed care in 2005–2008 with 18-months of subsequent enrollment. Medicaid encounter and state immunization registry data were then acquired. Auto-assigned infants were compared versus chosen plan infants on: (1) well-child visits (WCVs); (2) immunizations; (3) acute office visits; and (4) ED visits. Chi squared and rank-sum tests and logistic and negative binomial regression were used in bivariate and multivariable analyses for dichotomous and count data, respectively. 18 % of infants were auto-assigned. Auto-assigned infants were less likely to meet goal number of WCVs in 18-months of managed care enrollment (32 vs. 53 %, p < 0.001) and to be up-to-date on immunizations at 12 months of age (75 vs. 85 %, p < 0.001). Auto-assigned infants had fewer acute office visits (median: 4 vs. 5, p < 0.001) but were only slightly more likely to have 2 or more ED visits (51 vs. 46 %, p < 0.001) in 18-months of enrollment. All results were significant in multivariable analyses. Auto-assigned infants were less likely to use preventive and acute primary care but only slightly more likely to use emergency care. Future work is needed to understand mechanisms of differences in utilization, but auto-assigned children may represent a target group for efforts to promote pediatric preventive care in Medicaid. PMID:23775252
Zhao, Qian; Wang, Liping; Song, Ping; Li, Feng; Zhou, Xiaogang; Yu, Yaping; An, Zhiming; Wang, Xuli; Zhai, Yongping
2016-04-01
To explore the feature of primary light chain amyloidosis patients treated with high-dose melphalan with auto peripheral blood stem cell transplantation (auto-PBSCT) and bortezomib plus dexamethasone (VD). Thirty-eight patients diagnosed from September 2004 to September 2012 were analyzed retrospectively, including 15 cases received auto-PBSCT, 23 cases exposed with VD. The median follow-up duration for the patients was 34 months (range, 1-112 months), including auto-PBSCT group of 38 months (range, 5-112 months) and VD group of 31 months (range, 1-108 months). The organ response rate in all the patients was 39.5% (15/38), and the organ response rate between these two groups has no significant difference [33.3% (5/15) vs 43.5% (10/23), P=0.532]. However, the median time of organ response was significant difference [6 (3-10) months vs 3 (1-6) months, respectively (P=0.032)]. The 3-year overall survival (OS) rates in the two groups were 72.0% and 66.9%, and their average survival were 84.7 months and 75.9 months, respectively (P=0.683). In the patients with auto-PBSCT, the occurrence of III-IV grade of bone marrow suppression (P<0.001), fever (P<0.001), nausea and infection (P=0.006) were obviously higher than those with VD, but there was no statistically significant difference in pulmonary infection (P=0.069) and bloodstream infection (P=0.059). The preliminary results have presented that primary light chain amyloidosis patients treated with auto-PBSCT or VD had similar organ response rate and survival. However, more adverse events occurred in the group of auto-PBSCT.
Outpatient utilization by infants auto-assigned to Medicaid managed care plans.
Zickafoose, Joseph S; Cohn, Lisa M; Clark, Sarah J
2014-04-01
To test the hypothesis that infants auto-assigned to a Medicaid managed care plan would have lower primary care and higher emergency department (ED) utilization compared to infants with a chosen plan. Retrospective cohort study. Medicaid administrative data were used to identify all children 0-3 months of age at enrollment in Michigan Medicaid managed care in 2005-2008 with 18-months of subsequent enrollment. Medicaid encounter and state immunization registry data were then acquired. Auto-assigned infants were compared versus chosen plan infants on: (1) well-child visits (WCVs); (2) immunizations; (3) acute office visits; and (4) ED visits. Chi squared and rank-sum tests and logistic and negative binomial regression were used in bivariate and multivariable analyses for dichotomous and count data, respectively. 18% of infants were auto-assigned. Auto-assigned infants were less likely to meet goal number of WCVs in 18-months of managed care enrollment (32 vs. 53%, p < 0.001) and to be up-to-date on immunizations at 12 months of age (75 vs. 85%, p < 0.001). Auto-assigned infants had fewer acute office visits (median: 4 vs. 5, p < 0.001) but were only slightly more likely to have 2 or more ED visits (51 vs. 46%, p < 0.001) in 18-months of enrollment. All results were significant in multivariable analyses. Auto-assigned infants were less likely to use preventive and acute primary care but only slightly more likely to use emergency care. Future work is needed to understand mechanisms of differences in utilization, but auto-assigned children may represent a target group for efforts to promote pediatric preventive care in Medicaid.
Tuba-ovarian auto-amputation caused by ovarian teratoma in an adolescent girl.
Atıcı, Ahmet; Yılmaz, Engin; Karaman, Ayşe; Apaydın, Sema; Afşarlar, Çağatay Evrim
2017-01-01
Atıcı A, Yılmaz E, Karaman A, Apaydın S, Afşarlar ÇE. Tuba-ovarian auto-amputation caused by ovarian teratoma in an adolescent girl. Turk J Pediatr 2017; 59: 90-92. Ovarian auto-amputation is an extremely rare condition commonly encountered in the perinatal period. Spontaneous or secondary torsion of the ovary caused by an ovarian lesion may result in infarction and subsequent auto-amputation of the ovary. This paper demonstrates a case that underwent laparoscopic appendectomy with an incidental calcified auto-amputated right ovary. A 16-year-old adolescent girl was admitted to our department with a history of one-day abdominal pain. Physical examination of the patient revealed abdominal tenderness and rigidity on right lower quadrant. Her white blood cell count was 11x103/mL, and C-reactive protein was 69 mg/L. The patient underwent a laparoscopic appendectomy with a provisional diagnosis of acute appendicitis, and further exploration revealed a 2x2 cm white ovoid mass floating freely in the pelvis. The left ovary was clearly identified in its usual localization, but the right tuba was blindly ending without any fimbria or ovary. Postoperative course of the patient was uneventful, and she was discharged on postoperative day 2. The histopathological examination revealed a necrotic calcified ovarian teratoma. Auto-amputated ovary is a rare occasion mostly encountered during perinatal period, and it may be unilateral or bilateral. An auto-amputated ovarian mass may rarely be a teratoma although the most common cause of auto-amputation during perinatal and adolescent period is ovarian torsion due to an ovarian cyst.
Mostafa, Gehan Ahmed; Al-Ayadhi, Laila Yousef
2011-06-22
One of the most consistent biological findings in autism is the elevated blood serotonin levels. Immune abnormalities, including autoimmunity with production of brain specific auto-antibodies, are also commonly observed in this disorder. Hyperserotonemia may be one of the contributing factors to autoimmunity in some patients with autism through the reduction of T-helper (Th) 1-type cytokines. We are the first to investigate the possible role of hyperserotonemia in the induction of autoimmunity, as indicated by serum anti-myelin-basic protein (anti-MBP) auto-antibodies, in autism. Serum levels of serotonin and anti-MBP auto-antibodies were measured, by ELISA, in 50 autistic patients, aged between 5 and 12 years, and 30 healthy-matched children. Autistic children had significantly higher serum levels of serotonin and anti-MBP auto-antibodies than healthy children (P < 0.001 and P < 0.001, respectively). Increased serum levels of serotonin and anti-MBP auto-antibodies were found in 92% and 80%, respectively of autistic patients. Patients with severe autism had significantly higher serum serotonin levels than children with mild to moderate autism (P < 0.001). Serum serotonin levels had no significant correlations with serum levels of anti-MBP auto-antibodies in autistic patients (P = 0.39). Hyperserotonemia may not be one of the contributing factors to the increased frequency of serum anti-MBP auto-antibodies in some autistic children. These data should be treated with caution until further investigations are performed. However, inclusion of serum serotonin levels as a correlate may be useful in other future immune studies in autism to help unravel the long-standing mystery of hyperserotonemia and its possible role in the pathophysiology of this disorder.
2011-01-01
Background One of the most consistent biological findings in autism is the elevated blood serotonin levels. Immune abnormalities, including autoimmunity with production of brain specific auto-antibodies, are also commonly observed in this disorder. Hyperserotonemia may be one of the contributing factors to autoimmunity in some patients with autism through the reduction of T-helper (Th) 1-type cytokines. We are the first to investigate the possible role of hyperserotonemia in the induction of autoimmunity, as indicated by serum anti-myelin-basic protein (anti-MBP) auto-antibodies, in autism. Methods Serum levels of serotonin and anti-MBP auto-antibodies were measured, by ELISA, in 50 autistic patients, aged between 5 and 12 years, and 30 healthy-matched children. Results Autistic children had significantly higher serum levels of serotonin and anti-MBP auto-antibodies than healthy children (P < 0.001 and P < 0.001, respectively). Increased serum levels of serotonin and anti-MBP auto-antibodies were found in 92% and 80%, respectively of autistic patients. Patients with severe autism had significantly higher serum serotonin levels than children with mild to moderate autism (P < 0.001). Serum serotonin levels had no significant correlations with serum levels of anti-MBP auto-antibodies in autistic patients (P = 0.39). Conclusions Hyperserotonemia may not be one of the contributing factors to the increased frequency of serum anti-MBP auto-antibodies in some autistic children. These data should be treated with caution until further investigations are performed. However, inclusion of serum serotonin levels as a correlate may be useful in other future immune studies in autism to help unravel the long-standing mystery of hyperserotonemia and its possible role in the pathophysiology of this disorder. PMID:21696608
Auto-induction for high level production of biologically active reteplase in Escherichia coli.
Fathi-Roudsari, Mehrnoosh; Maghsoudi, Nader; Maghsoudi, Amirhossein; Niazi, Sepideh; Soleiman, Morvarid
2018-06-07
Reteplase is a third generation tissue plasminogen activator (tPA) with a modified structure and prolonged half-life in comparison to native tPA. As a non-glycosylated protein, reteplase is expressed in Escherichia coli. Due to presence of several disulfide bonds, high level production of reteplase is complicated and needs extra steps for conversion to biologically active form. Auto-induction represents a method for high-yield growth of bacterial cells and higher expression of recombinant proteins. Here we have tried to optimize the auto-induction procedure for soluble and active expression of reteplase in E. coli. Results showed that using auto-induction strategy at 37 °C, Rosetta-gami (DE3) had the highest level of active and soluble reteplase production in comparison to E. coli strains BL21 (DE3), and Shuffel T7. Temperature dominantly affected the level of active reteplase production. Decreasing the temperature to 25 and 18 °C increased the level of active reteplase by 20 and 60%, respectively. The composition of auto-induction medium also dramatically changed the active production of reteplase in cytoplasm. Using higher enriched auto-induction medium, super broth base including trace elements, significantly increased biologically active reteplase by 30%. It is demonstrated here that auto-induction is a powerful method for expression of biologically active reteplase in oxidative cytoplasm of Rosetta-gami. Optimizing expression condition by decreasing temperature and using an enriched auto-induction medium resulted in at least three times higher level of active reteplase production. Production of correctly folded and active reteplase in spite of its complex structure helps for removal of inefficient and cumbersome step of refolding. Copyright © 2018. Published by Elsevier Inc.
Stephen, Peter; Mahalakshmy, Thulasingam; Manju, Rajaram; Laksham, Karthik B; Subramani, Sudalai; Panda, Kanhu; Sarkar, Sonali
2018-01-01
Auto-rickshaw (three wheelers open cabin type of vehicle) drivers are exposed to traffic air pollution. Studies have demonstrated reduced pulmonary function among drivers. However, limited studies have determined the prevalence of chronic respiratory symptoms or chronic obstructive pulmonary disease (COPD) among drivers. Among auto-rickshaw drivers of urban Puducherry to determine prevalence of (i) chronic respiratory symptoms by using Indian Study on Epidemiology of Asthma, Respiratory Symptoms, and Chronic Bronchitis (INSEARCH) questionnaire and (ii) COPD by measuring peak expiratory flow rate (PEFR). Cross-sectional, descriptive study. Cluster random sampling was used to select 297 auto-rickshaw drivers. Subjects were interviewed using the INSEARCH questionnaire. PEFR was measured using Wright's peak flow meter. We also assessed exposure to tobacco smoke. Prevalence and 95% confidence interval of chronic respiratory symptoms and COPD were calculated. All the auto-rickshaw drivers were male, and 75% were in the age group of 31-50 years. They spend most of the time on the roadside either driving or waiting at the auto-stand. Prevalence of nonspecific respiratory symptoms among auto-rickshaw drivers was 76% (breathlessness on exertion 68%, cough at night and phlegm in the morning 22%, wheezing 18% assessed for last 12 months). Around 28% of them had PEFR <80%. The prevalence of tobacco smoking was also high (64%), and 100% had exposure to tobacco smoke at the workplace. The nonspecific chronic symptoms were high among auto-rickshaw drivers as compared to the general population noted from a multicentric study done in India. We recommend that auto-rickshaw drivers should use personal protective equipment and would require regular screening and treatment for respiratory impairment.
Cannesson, Maxime; Tanabe, Masaki; Suffoletto, Matthew S; McNamara, Dennis M; Madan, Shobhit; Lacomis, Joan M; Gorcsan, John
2007-01-16
We sought to test the hypothesis that a novel 2-dimensional echocardiographic image analysis system using artificial intelligence-learned pattern recognition can rapidly and reproducibly calculate ejection fraction (EF). Echocardiographic EF by manual tracing is time consuming, and visual assessment is inherently subjective. We studied 218 patients (72 female), including 165 with abnormal left ventricular (LV) function. Auto EF incorporated a database trained on >10,000 human EF tracings to automatically locate and track the LV endocardium from routine grayscale digital cineloops and calculate EF in 15 s. Auto EF results were independently compared with manually traced biplane Simpson's rule, visual EF, and magnetic resonance imaging (MRI) in a subset. Auto EF was possible in 200 (92%) of consecutive patients, of which 77% were completely automated and 23% required manual editing. Auto EF correlated well with manual EF (r = 0.98; 6% limits of agreement) and required less time per patient (48 +/- 26 s vs. 102 +/- 21 s; p < 0.01). Auto EF correlated well with visual EF by expert readers (r = 0.96; p < 0.001), but interobserver variability was greater (3.4 +/- 2.9% vs. 9.8 +/- 5.7%, respectively; p < 0.001). Visual EF was less accurate by novice readers (r = 0.82; 19% limits of agreement) and improved with trainee-operated Auto EF (r = 0.96; 7% limits of agreement). Auto EF also correlated with MRI EF (n = 21) (r = 0.95; 12% limits of agreement), but underestimated absolute volumes (r = 0.95; bias of -36 +/- 27 ml overall). Auto EF can automatically calculate EF similarly to results by manual biplane Simpson's rule and MRI, with less variability than visual EF, and has clinical potential.
Fenske, Timothy S.; Zhang, Mei-Jie; Carreras, Jeanette; Ayala, Ernesto; Burns, Linda J.; Cashen, Amanda; Costa, Luciano J.; Freytes, César O.; Gale, Robert P.; Hamadani, Mehdi; Holmberg, Leona A.; Inwards, David J.; Lazarus, Hillard M.; Maziarz, Richard T.; Munker, Reinhold; Perales, Miguel-Angel; Rizzieri, David A.; Schouten, Harry C.; Smith, Sonali M.; Waller, Edmund K.; Wirk, Baldeep M.; Laport, Ginna G.; Maloney, David G.; Montoto, Silvia; Hari, Parameswaran N.
2014-01-01
Purpose To examine the outcomes of patients with chemotherapy-sensitive mantle-cell lymphoma (MCL) following a first hematopoietic stem-cell transplantation (HCT), comparing outcomes with autologous (auto) versus reduced-intensity conditioning allogeneic (RIC allo) HCT and with transplantation applied at different times in the disease course. Patients and Methods In all, 519 patients who received transplantations between 1996 and 2007 and were reported to the Center for International Blood and Marrow Transplant Research were analyzed. The early transplantation cohort was defined as those patients in first partial or complete remission with no more than two lines of chemotherapy. The late transplantation cohort was defined as all the remaining patients. Results Auto-HCT and RIC allo-HCT resulted in similar overall survival from transplantation for both the early (at 5 years: 61% auto-HCT v 62% RIC allo-HCT; P = .951) and late cohorts (at 5 years: 44% auto-HCT v 31% RIC allo-HCT; P = .202). In both early and late transplantation cohorts, progression/relapse was lower and nonrelapse mortality was higher in the allo-HCT group. Overall survival and progression-free survival were highest in patients who underwent auto-HCT in first complete response. Multivariate analysis of survival from diagnosis identified a survival benefit favoring early HCT for both auto-HCT and RIC allo-HCT. Conclusion For patients with chemotherapy-sensitive MCL, the optimal timing for HCT is early in the disease course. Outcomes are particularly favorable for patients undergoing auto-HCT in first complete remission. For those unable to achieve complete remission after two lines of chemotherapy or those with relapsed disease, either auto-HCT or RIC allo-HCT may be effective, although the chance for long-term remission and survival is lower. PMID:24344210
Fenske, Timothy S; Zhang, Mei-Jie; Carreras, Jeanette; Ayala, Ernesto; Burns, Linda J; Cashen, Amanda; Costa, Luciano J; Freytes, César O; Gale, Robert P; Hamadani, Mehdi; Holmberg, Leona A; Inwards, David J; Lazarus, Hillard M; Maziarz, Richard T; Munker, Reinhold; Perales, Miguel-Angel; Rizzieri, David A; Schouten, Harry C; Smith, Sonali M; Waller, Edmund K; Wirk, Baldeep M; Laport, Ginna G; Maloney, David G; Montoto, Silvia; Hari, Parameswaran N
2014-02-01
To examine the outcomes of patients with chemotherapy-sensitive mantle-cell lymphoma (MCL) following a first hematopoietic stem-cell transplantation (HCT), comparing outcomes with autologous (auto) versus reduced-intensity conditioning allogeneic (RIC allo) HCT and with transplantation applied at different times in the disease course. In all, 519 patients who received transplantations between 1996 and 2007 and were reported to the Center for International Blood and Marrow Transplant Research were analyzed. The early transplantation cohort was defined as those patients in first partial or complete remission with no more than two lines of chemotherapy. The late transplantation cohort was defined as all the remaining patients. Auto-HCT and RIC allo-HCT resulted in similar overall survival from transplantation for both the early (at 5 years: 61% auto-HCT v 62% RIC allo-HCT; P = .951) and late cohorts (at 5 years: 44% auto-HCT v 31% RIC allo-HCT; P = .202). In both early and late transplantation cohorts, progression/relapse was lower and nonrelapse mortality was higher in the allo-HCT group. Overall survival and progression-free survival were highest in patients who underwent auto-HCT in first complete response. Multivariate analysis of survival from diagnosis identified a survival benefit favoring early HCT for both auto-HCT and RIC allo-HCT. For patients with chemotherapy-sensitive MCL, the optimal timing for HCT is early in the disease course. Outcomes are particularly favorable for patients undergoing auto-HCT in first complete remission. For those unable to achieve complete remission after two lines of chemotherapy or those with relapsed disease, either auto-HCT or RIC allo-HCT may be effective, although the chance for long-term remission and survival is lower.
Smith, Sonali M; Godfrey, James; Ahn, Kwang Woo; DiGilio, Alyssa; Ahmed, Sairah; Agrawal, Vaibhav; Bachanova, Veronika; Bacher, Ulrike; Bashey, Asad; Bolaños-Meade, Javier; Cairo, Mitchell; Chen, Andy; Chhabra, Saurabh; Copelan, Edward; Dahi, Parastoo B; Aljurf, Mahmoud; Farooq, Umar; Ganguly, Siddhartha; Hertzberg, Mark; Holmberg, Leona; Inwards, David; Kanate, Abraham S; Karmali, Reem; Kenkre, Vaishalee P; Kharfan-Dabaja, Mohamed A; Klein, Andreas; Lazarus, Hillard M; Mei, Matthew; Mussetti, Alberto; Nishihori, Taiga; Ramakrishnan Geethakumari, Praveen; Saad, Ayman; Savani, Bipin N; Schouten, Harry C; Shah, Nirav; Urbano-Ispizua, Alvaro; Vij, Ravi; Vose, Julie; Sureda, Anna; Hamadani, Mehdi
2018-06-15
Early treatment failure (ETF) in follicular lymphoma (FL), defined as relapse or progression within 2 years of frontline chemoimmunotherapy, is a newly recognized marker of poor survival and identifies a high-risk group of patients with an expected 5-year overall survival (OS) rate of approximately 50%. Transplantation is an established option for relapsed FL, but its efficacy in this specific ETF FL population has not been previously evaluated. This study compared autologous hematopoietic stem cell transplantation (auto-HCT) with either matched sibling donor (MSD) or matched unrelated donor (MUD) allogeneic hematopoietic cell transplantation (allo-HCT) as the first transplantation approach for patients with ETF FL (age ≥ 18 years) undergoing auto-HCT or allo-HCT between 2002 and 2014. The primary endpoint was OS. The secondary endpoints were progression-free survival, relapse, and nonrelapse mortality (NRM). Four hundred forty FL patients had ETF (auto-HCT, 240; MSD hematopoietic stem cell transplantation [HCT], 105; and MUD HCT, 95). With a median follow-up of 69 to 73 months, the adjusted probability of 5-year OS was significantly higher after auto-HCT (70%) or MSD HCT (73%) versus MUD HCT (49%; P = .0008). The 5-year adjusted probability of NRM was significantly lower for auto-HCT (5%) versus MSD (17%) or MUD HCT (33%; P < .0001). The 5-year adjusted probability of disease relapse was lower with MSD (31%) or MUD HCT (23%) versus auto-HCT (58%; P < .0001). Patients with high-risk FL, as defined by ETF, undergoing auto-HCT for FL have low NRM and a promising 5-year OS rate (70%). MSD HCT has lower relapse rates than auto-HCT but similar OS. Cancer 2018;124:2541-51. © 2018 American Cancer Society. © 2018 American Cancer Society.
Stephen, Peter; Mahalakshmy, Thulasingam; Manju, Rajaram; Laksham, Karthik B.; Subramani, Sudalai; Panda, Kanhu; Sarkar, Sonali
2018-01-01
Context: Auto-rickshaw (three wheelers open cabin type of vehicle) drivers are exposed to traffic air pollution. Studies have demonstrated reduced pulmonary function among drivers. However, limited studies have determined the prevalence of chronic respiratory symptoms or chronic obstructive pulmonary disease (COPD) among drivers. Aims: Among auto-rickshaw drivers of urban Puducherry to determine prevalence of (i) chronic respiratory symptoms by using Indian Study on Epidemiology of Asthma, Respiratory Symptoms, and Chronic Bronchitis (INSEARCH) questionnaire and (ii) COPD by measuring peak expiratory flow rate (PEFR). Setting and Designs: Cross-sectional, descriptive study. Subjects and Methods: Cluster random sampling was used to select 297 auto-rickshaw drivers. Subjects were interviewed using the INSEARCH questionnaire. PEFR was measured using Wright's peak flow meter. We also assessed exposure to tobacco smoke. Statistical Analysis Used: Prevalence and 95% confidence interval of chronic respiratory symptoms and COPD were calculated. Results: All the auto-rickshaw drivers were male, and 75% were in the age group of 31–50 years. They spend most of the time on the roadside either driving or waiting at the auto-stand. Prevalence of nonspecific respiratory symptoms among auto-rickshaw drivers was 76% (breathlessness on exertion 68%, cough at night and phlegm in the morning 22%, wheezing 18% assessed for last 12 months). Around 28% of them had PEFR <80%. The prevalence of tobacco smoking was also high (64%), and 100% had exposure to tobacco smoke at the workplace. Conclusion: The nonspecific chronic symptoms were high among auto-rickshaw drivers as compared to the general population noted from a multicentric study done in India. We recommend that auto-rickshaw drivers should use personal protective equipment and would require regular screening and treatment for respiratory impairment. PMID:29743784
A framework for feature extraction from hospital medical data with applications in risk prediction.
Tran, Truyen; Luo, Wei; Phung, Dinh; Gupta, Sunil; Rana, Santu; Kennedy, Richard Lee; Larkins, Ann; Venkatesh, Svetha
2014-12-30
Feature engineering is a time consuming component of predictive modeling. We propose a versatile platform to automatically extract features for risk prediction, based on a pre-defined and extensible entity schema. The extraction is independent of disease type or risk prediction task. We contrast auto-extracted features to baselines generated from the Elixhauser comorbidities. Hospital medical records was transformed to event sequences, to which filters were applied to extract feature sets capturing diversity in temporal scales and data types. The features were evaluated on a readmission prediction task, comparing with baseline feature sets generated from the Elixhauser comorbidities. The prediction model was through logistic regression with elastic net regularization. Predictions horizons of 1, 2, 3, 6, 12 months were considered for four diverse diseases: diabetes, COPD, mental disorders and pneumonia, with derivation and validation cohorts defined on non-overlapping data-collection periods. For unplanned readmissions, auto-extracted feature set using socio-demographic information and medical records, outperformed baselines derived from the socio-demographic information and Elixhauser comorbidities, over 20 settings (5 prediction horizons over 4 diseases). In particular over 30-day prediction, the AUCs are: COPD-baseline: 0.60 (95% CI: 0.57, 0.63), auto-extracted: 0.67 (0.64, 0.70); diabetes-baseline: 0.60 (0.58, 0.63), auto-extracted: 0.67 (0.64, 0.69); mental disorders-baseline: 0.57 (0.54, 0.60), auto-extracted: 0.69 (0.64,0.70); pneumonia-baseline: 0.61 (0.59, 0.63), auto-extracted: 0.70 (0.67, 0.72). The advantages of auto-extracted standard features from complex medical records, in a disease and task agnostic manner were demonstrated. Auto-extracted features have good predictive power over multiple time horizons. Such feature sets have potential to form the foundation of complex automated analytic tasks.
Crashworthiness Assessment of Auto-body Members Considering the Fabrication Histories
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huh, Hoon; Song, Jung-Han; Kim, Kee-Poong
2005-08-05
This paper is concerned with crashworthiness of auto-body members considering the effect of fabrication. Most auto-body members are fabricated with sheet metal forming process and welding process that induce fabrication histories such as the plastic work hardening, non-uniform thickness distribution and residual stress. Crash simulation is carried out for auto-body members with LS-DYNA3D in order to identify the fabrication effect on the crashworthiness. The analysis calculated crash mode, the reaction force and the energy absorption for crashworthiness assessment with the forming effect. The result shows that the crash analysis with considering the forming history leads to a different result frommore » that without considering the forming effect. The analysis results demonstrate that the design of auto-body members should be carried out considering the forming history for accurate assessment of the crashworthiness.« less
Gene-Auto: Automatic Software Code Generation for Real-Time Embedded Systems
NASA Astrophysics Data System (ADS)
Rugina, A.-E.; Thomas, D.; Olive, X.; Veran, G.
2008-08-01
This paper gives an overview of the Gene-Auto ITEA European project, which aims at building a qualified C code generator from mathematical models under Matlab-Simulink and Scilab-Scicos. The project is driven by major European industry partners, active in the real-time embedded systems domains. The Gene- Auto code generator will significantly improve the current development processes in such domains by shortening the time to market and by guaranteeing the quality of the generated code through the use of formal methods. The first version of the Gene-Auto code generator has already been released and has gone thought a validation phase on real-life case studies defined by each project partner. The validation results are taken into account in the implementation of the second version of the code generator. The partners aim at introducing the Gene-Auto results into industrial development by 2010.
Terwilliger, Thomas C; Grosse-Kunstleve, Ralf W; Afonine, Pavel V; Moriarty, Nigel W; Zwart, Peter H; Hung, Li Wei; Read, Randy J; Adams, Paul D
2008-01-01
The PHENIX AutoBuild wizard is a highly automated tool for iterative model building, structure refinement and density modification using RESOLVE model building, RESOLVE statistical density modification and phenix.refine structure refinement. Recent advances in the AutoBuild wizard and phenix.refine include automated detection and application of NCS from models as they are built, extensive model-completion algorithms and automated solvent-molecule picking. Model-completion algorithms in the AutoBuild wizard include loop building, crossovers between chains in different models of a structure and side-chain optimization. The AutoBuild wizard has been applied to a set of 48 structures at resolutions ranging from 1.1 to 3.2 A, resulting in a mean R factor of 0.24 and a mean free R factor of 0.29. The R factor of the final model is dependent on the quality of the starting electron density and is relatively independent of resolution.
Auto-recognition of surfaces and auto-generation of material removal volume for finishing process
NASA Astrophysics Data System (ADS)
Kataraki, Pramod S.; Salman Abu Mansor, Mohd
2018-03-01
Auto-recognition of a surface and auto-generation of material removal volumes for the so recognised surfaces has become a need to achieve successful downstream manufacturing activities like automated process planning and scheduling. Few researchers have contributed to generation of material removal volume for a product but resulted in material removal volume discontinuity between two adjacent material removal volumes generated from two adjacent faces that form convex geometry. The need for limitation free material removal volume generation was attempted and an algorithm that automatically recognises computer aided design (CAD) model’s surface and also auto-generate material removal volume for finishing process of the recognised surfaces was developed. The surfaces of CAD model are successfully recognised by the developed algorithm and required material removal volume is obtained. The material removal volume discontinuity limitation that occurred in fewer studies is eliminated.
Rodríguez-Cattáneo, A; Aguilera, P; Cilleruelo, E; Crampton, W G R; Caputi, A A
2013-04-15
Previous studies describe six factors accounting for interspecific diversity of electric organ discharge (EOD) waveforms in Gymnotus. At the cellular level, three factors determine the locally generated waveforms: (1) electrocyte geometry and channel repertoire; (2) the localization of synaptic contacts on electrocyte surfaces; and (3) electric activity of electromotor axons preceding the discharge of electrocytes. At the organismic level, three factors determine the integration of the EOD as a behavioral unit: (4) the distribution of different types of electrocytes and specialized passive tissue forming the electric organ (EO); (5) the neural mechanisms of electrocyte discharge coordination; and (6) post-effector mechanisms. Here, we reconfirm the importance of the first five of these factors based on comparative studies of a wider diversity of Gymnotus than previously investigated. Additionally, we report a hitherto unseen aspect of EOD diversity in Gymnotus. The central region of the EO (which has the largest weight on the conspecific-received field) usually exhibits a negative-positive-negative pattern where the delay between the early negative and positive peaks (determined by neural coordination mechanisms) matches the delay between the positive and late negative peaks (determined by electrocyte responsiveness). Because delays between peaks typically determine the peak power frequency, this matching implies a co-evolution of neural and myogenic coordination mechanisms in determining the spectral specificity of the intraspecific communication channel. Finally, we define four functional species groups based on EO/EOD structure. The first three exhibit a heterogeneous EO in which doubly innervated electrocytes are responsible for a main triphasic complex. Group I species exhibit a characteristic cephalic extension of the EO. Group II species exhibit an early positive component of putative neural origin, and strong EO auto-excitability. Group III species exhibit an early, slow, negative wave of abdominal origin, and variation in EO auto-excitability. Representatives of Group IV generate a unique waveform comprising a main positive peak followed by a small, load-dependent negative component.
Zhu, Kaixian; Aouf, Sami; Roisman, Gabriel; Escourrou, Pierre
2016-01-01
Study Objectives: Pressure-relief features are aimed at improving the patient's comfort during continuous positive airway pressure (CPAP) treatment for obstructive sleep apnea. The objective of this study was to determine the effect of these therapy features on fixed CPAP and autotitrating CPAP (APAP) treatment efficacy. Methods: Seven pressure-relief features applied by three CPAP devices were included in our study (Remstar Auto: C-Flex 3, C-Flex+ 3, A-Flex 3, P-Flex; AirSense 10: EPR 3; Prisma 20A: SoftPAP 2 and 3). In fixed CPAP, the devices were subjected to a 10-min bench-simulated obstructive apnea sequence (initial apnea-hypopnea index, AHI = 60/h) with and without pressure-relief features. In APAP, the sequence was lengthened to 4.2 h (initial AHI = 58.6/h). The residual AHI and mean/median pressure were compared with and without pressure-relief features. Results: Compared to conventional CPAP, where pressure was adjusted to be just sufficient to control the simulated obstructive events, C-Flex+ 3, P-Flex, and EPR 3 failed to normalize the breathing flow and did not reduce the AHI. The mean pressures with the three features, respectively, were 1.8, 2.6, and 2.6 cmH2O lower than the conventional CPAP. Compared to conventional APAP, similar levels of control were observed with pressure-relief features, apart from P-Flex where the delivered mean pressure was lower and residual AHI greater. The device-reported mean/median pressures in APAP with A-Flex 3, P-Flex, EPR 3, and SoftPAP 3 were higher than that measured on the bench. Conclusions: Pressure-relief features may attenuate CPAP efficacy if not adjusted for at the time of their introduction. In clinical practice, efficacy can be ensured by increasing the therapeutic pressure delivered by fixed CPAP or by enabling the pressure-relief features prior to initial pressure titration. Device-reported pressures in APAP devices with pressure relief activated may overstate delivered pressures. Citation: Zhu K, Aouf S, Roisman G, Escourrou P. Pressure-relief features of fixed and autotitrating continuous positive airway pressure may impair their efficacy: evaluation with a respiratory bench model. J Clin Sleep Med 2016;12(3):385–392. PMID:26564383
16 CFR 640.4 - Content, form, and timing of risk-based pricing notices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... credit to a consumer for the purpose of financing the purchase of an automobile from an auto dealer or... section, § 640.5(e)(3), or § 640.5(f)(4), as applicable; or (ii) Arranges to have the auto dealer or other...), as applicable, and maintains reasonable policies and procedures to verify that the auto dealer or...
16 CFR 640.4 - Content, form, and timing of risk-based pricing notices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... credit to a consumer for the purpose of financing the purchase of an automobile from an auto dealer or... section, § 640.5(e)(3), or § 640.5(f)(4), as applicable; or (ii) Arranges to have the auto dealer or other...), as applicable, and maintains reasonable policies and procedures to verify that the auto dealer or...
12 CFR 222.73 - Content, form, and timing of risk-based pricing notices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... for the purpose of financing the purchase of an automobile from an auto dealer or other party that is..., § 222.74(e)(3), or § 222.74(f)(4), as applicable; or (ii) Arranges to have the auto dealer or other...)(4), as applicable, and maintains reasonable policies and procedures to verify that the auto dealer...
12 CFR 222.73 - Content, form, and timing of risk-based pricing notices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... for the purpose of financing the purchase of an automobile from an auto dealer or other party that is..., § 222.74(e)(3), or § 222.74(f)(4), as applicable; or (ii) Arranges to have the auto dealer or other...)(4), as applicable, and maintains reasonable policies and procedures to verify that the auto dealer...
12 CFR 1022.73 - Content, form, and timing of risk-based pricing notices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... an auto dealer or other party that is not affiliated with the person, any requirement to provide a...) Arranges to have the auto dealer or other party provide a notice described in § 1022.72(a), § 1022.74(e... policies and procedures to verify that the auto dealer or other party provides such notice to the consumer...
16 CFR 640.4 - Content, form, and timing of risk-based pricing notices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... credit to a consumer for the purpose of financing the purchase of an automobile from an auto dealer or... section, § 640.5(e)(3), or § 640.5(f)(4), as applicable; or (ii) Arranges to have the auto dealer or other...), as applicable, and maintains reasonable policies and procedures to verify that the auto dealer or...
16 CFR 640.4 - Content, form, and timing of risk-based pricing notices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... credit to a consumer for the purpose of financing the purchase of an automobile from an auto dealer or... section, § 640.5(e)(3), or § 640.5(f)(4), as applicable; or (ii) Arranges to have the auto dealer or other...), as applicable, and maintains reasonable policies and procedures to verify that the auto dealer or...
[Design of blood-pressure parameter auto-acquisition circuit].
Chen, Y P; Zhang, D L; Bai, H W; Zhang, D A
2000-02-01
This paper presents the realization and design of a kind of blood-pressure parameter auto-acquisition circuit. The auto-acquisition of blood-pressure parameter controlled by 89C2051 single chip microcomputer is accomplished by collecting and processing the driving signal of LCD. The circuit that is successfully applied in the home unit of telemedicine system has the simple and reliable properties.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-09
... Orders of Securities Priced Under One Dollar in the Auto Execution Mode of Order Interaction to 0.25% of... for liquidity adding displayed orders of securities priced under one dollar in the Auto Execution mode of order interaction (``AutoEx'') \\3\\ to 0.25% of trade value. \\3\\ The Exchange's two modes of order...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-12
... and higher in the Automatic Execution mode of order interaction (``AutoEx'') \\3\\. In addition, the... Rule 11.13(b). \\4\\ Id. AutoEx Take Fee for Securities Priced One Dollar and Higher For orders in securities priced one dollar and above that take liquidity in AutoEx, the proposed rule change lowers the...
ERIC Educational Resources Information Center
Riedler, Martina
2016-01-01
In this self-reflective auto-ethnographic research, the author shares her experiences of introspection, change and professional growth as an art educator in an international context. Auto-ethnography is an approach to qualitative inquiry in which the researcher employs self-reflection to explore her personal experiences and connect these…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-25
... A340 aeroplane will revert to alternate law, the autopilot (AP) and the auto-thrust (A/THR... guidance computers will: --Display FD bars again, and --Enable autopilot and auto-thrust re-engagement... A330 or A340 aeroplane will revert to alternate law, the autopilot (AP) and the auto-thrust (A/THR...
Anwar, Khaleeq; Ejaz, Sohail; Ashraf, Muhammad; Altaf, Imran; Anjum, Aftab Ahmad
2013-07-01
Vehicular air pollution is a mounting health issue of the modern age, particularly in urban populations of the developing nations. Auto-rickshaws are not considered eco-friendly as to their inefficient engines producing large amount of particulate matter (PM), thus posing significant environmental threat. The present study was conducted to ascertain the cytotoxic, phytotoxic, and mutagenic potential of PM from gasoline-powered two-stroke auto-rickshaws (TSA) and compressed natural gas-powered four-stroke auto-rickshaws (FSA). Based on the increased amount of aluminum quantified during proton-induced X-ray emission analysis of PM from TSA and FSA, different concentrations of aluminum sulfate were also tested to determine its eco-toxicological potential. The MTT assay demonstrated significant (p < 0.001) dose-dependent cytotoxic effects of different concentrations of TSA, FSA, and aluminum sulfate on BHK-21 cell line. LC50 of TSA, FSA, and aluminum sulfate was quantified at 16, 11, and 23.8 μg/ml, respectively, establishing PM from FSA, a highly cytotoxic material. In case of phytotoxicity screening using Zea mays, the results demonstrated that all three tested materials were equally phytotoxic at higher concentrations producing significant reduction (p < 0.001) in seed germination. Aluminum sulfate proved to be a highly phytotoxic agent even at its lowest concentration. Mutagenicity was assessed by fluctuation Salmonella reverse mutation assay adopting TA100 and TA98 mutant strains with (+S9) and without (-S9) metabolic activation. Despite the fact that different concentrations of PM from both sources, i.e., TSA and FSA were highly mutagenic (p < 0.001) even at lower concentrations, the mutagenic index was higher in TSA. Data advocate that all tested materials are equally ecotoxic, and if the existing trend of atmospheric pollution by auto-rickshaws is continued, airborne heavy metals will seriously affect the normal growth of local inhabitants and increased contamination of agricultural products, which will amplify the dietary intake of the toxic elements and could result in genetic mutation or long-term health implications.
2010-04-21
2006·EX·L, Leather , Nice! 26k mi $17,977 #B21244A 1~-8556 ACCORD EX 11)01· V6, Auto,lthr, Moon Roof. #6302A $6,988 HEUBERGER MOTORS 475-1920...ns’~fl8~\\!Tv DODGE FIT 2009·Sport Pkg, Auto, Loaded #101399A $15,988 HEUIIEIIGER MOTORS 475-1920 Hyundai • Cars SONATALTD2008· Auto, Leather ...37Sol C <:LASS -Every Op· bon, NAV, Black/ Tan . $27,999 #G343 WHY PAY R!TAIU SMART CHOICE AUTO 641·37Sol E3502006 $31),995 #U678 Red
NASA Astrophysics Data System (ADS)
Chairunnisa, S.; Setiawan, N.; Irkham; Ekawati, K.; Anwar, A.; Fitri, A. DP
2018-02-01
Fish Aggregation Device (FAD) is a fishing tool that serves to collect fish at a place to facilitate fishermen in the process of fishing. The use of light is also proven to help the process of fishing at night. AUTO-LION (Automatic Lighting Rumpon) is a FADs innovation equipped with fish-eating sound and solar-powered lights that can be activated automatically when it is dark or nighttime.The purpose of this study was to determine the effect of AUTO-LION use on fishermen catch. The research method used is experimental fishing.The research was conducted on May 2017 on the stationary lift net in Semarang Waters. The results showed the catch as much as 10.55 kg without the use of AUTO-LION, 15.05 kg on the use of FADs, 19.08 kg on the use of FADs with sound, 27.04 kg on the use of FADs with light, and 40.01 kg on the use of AUTO-LION. Based on these results it can be seen that the use of AUTO-LION can increase the catch of fishermen, especially when the light is activated.
AutoFACT: An Automatic Functional Annotation and Classification Tool
Koski, Liisa B; Gray, Michael W; Lang, B Franz; Burger, Gertraud
2005-01-01
Background Assignment of function to new molecular sequence data is an essential step in genomics projects. The usual process involves similarity searches of a given sequence against one or more databases, an arduous process for large datasets. Results We present AutoFACT, a fully automated and customizable annotation tool that assigns biologically informative functions to a sequence. Key features of this tool are that it (1) analyzes nucleotide and protein sequence data; (2) determines the most informative functional description by combining multiple BLAST reports from several user-selected databases; (3) assigns putative metabolic pathways, functional classes, enzyme classes, GeneOntology terms and locus names; and (4) generates output in HTML, text and GFF formats for the user's convenience. We have compared AutoFACT to four well-established annotation pipelines. The error rate of functional annotation is estimated to be only between 1–2%. Comparison of AutoFACT to the traditional top-BLAST-hit annotation method shows that our procedure increases the number of functionally informative annotations by approximately 50%. Conclusion AutoFACT will serve as a useful annotation tool for smaller sequencing groups lacking dedicated bioinformatics staff. It is implemented in PERL and runs on LINUX/UNIX platforms. AutoFACT is available at . PMID:15960857
Neuropsychiatric lupus and auto-antibodies against ionotropic glutamate receptor (NMDAR)
Cohen-Solal, J.F.G.; Diamond, B.
2010-01-01
Almost half of lupus patients will experience neuropsychiatric symptoms during the course of their disease. The etiology of the neuronal damages are still uncertain and probably multiple. Auto-antibodies reactive with brain have been postulated to play a role. The observation of pathogenic auto-antibodies binding the NR2A and NR2B subunits of the ionotropic glutamate receptor (NMDAR) illustrates this hypothesis. First studies showed that 40% of lupus patients possess serum titers of anti-NR2A/B antibody, but the presence of these auto-antibodies is not always associated with the occurrence of neuronal damages or neuropsychiatric symptoms. Nevertheless, their presence is observed in the cerebro-spinal fluid (CSF) of one half of the patients suffering from neurolupus. The presence in the serum of these auto-antibodies anti-NR2A/B of the NMDAR is preliminary to their presence in the CSF where their deleterious effect is observable. Their entry into the brain is dependent on a breach of the blood brain barrier (BBB). In conclusion, the serum titer of auto-antibodies against NR2A/B subunits is an indication of the potential for neuro-psychiatric manifestations during the course of the disease. PMID:20605660
Ghio, Andrew J; Sangani, Rahul G; Brighton, Luisa E; Carson, John L
2010-06-01
Macrophages from smokers demonstrate an increased auto-fluorescence. Similarly, auto-fluorescence follows in vitro exposure of macrophages to cigarette smoke condensate (i.e., the particulate fraction of cigarette smoke). The composition of particles in cigarette smoke can be comparable to air pollution particles. We tested the postulate that macrophages exposed to air pollution particles could demonstrate auto-fluorescence. Healthy nonsmoking and healthy smoking volunteers (both 18-40 years of age) underwent fiberoptic bronchoscopy with bronchoalveolar lavage and alveolar macrophages isolated. Macrophages were incubated at 37 degrees C in 5% CO(2) with either PBS or 100 microg/mL particle for both 1 and 24 h. Particles included a residual oil fly ash, Mt. St. Helens volcanic ash, and ambient air particles collected from St. Louis, Missouri and Salt Lake City, Utah. At the end of incubation, 50 microL of the cell suspension was cytocentrifuged and examined at modes for viewing fluorescein isothiocyanate (FITC) and rhodamine fluorescence. Both emission source air pollution particles demonstrated FITC and rhodamine auto-fluorescence at 1 and 24 h, but the signal following incubation of the macrophages with oil fly ash appeared greater. Similarly, the ambient particles were associated with auto-fluorescence by the alveolar macrophages and this appeared to be dose-dependent. We conclude that exposure of macrophages to air pollution particles can be associated with auto-fluorescence in the FITC and rhodamine modes. c) 2009 Wiley-Liss, Inc
Zhang, Miao; Bommer, Martin; Chatterjee, Ruchira; ...
2017-07-18
In plants, algae and cyanobacteria, Photosystem II (PSII) catalyzes the light-driven splitting of water at a protein-bound Mn 4CaO 5-cluster, the water-oxidizing complex (WOC). In the photosynthetic organisms, the light-driven formation of the WOC from dissolved metal ions is a key process because it is essential in both initial activation and continuous repair of PSII. Structural information is required for understanding of this chaperone-free metal-cluster assembly. For the first time, we obtained a structure of PSII from Thermosynechococcus elongatus without the Mn 4CaO 5-cluster. Surprisingly, cluster-removal leaves the positions of all coordinating amino acid residues and most nearby water moleculesmore » largely unaffected, resulting in a pre-organized ligand shell for kinetically competent and error-free photo-assembly of the Mn 4CaO 5-cluster. First experiments initiating (i) partial disassembly and (ii) partial re-assembly after complete depletion of the Mn4CaO5-cluster agree with a specific bi-manganese cluster, likely a di-µ-oxo bridged pair of Mn(III) ions, as an assembly intermediate.« less
Sleep Disordered Breathing in Patients with Heart Failure: Pathophysiology and Management
Sharma, Bhavneesh; McSharry, David; Malhotra, Atul
2013-01-01
Opinion statement Sleep disordered breathing (SDB) is common in heart failure patients across the range of ejection fractions and is associated with adverse prognosis. Although effective pharmacologic and device-based treatment of heart failure may reduce the frequency or severity of SDB, heart failure treatment alone may not be adequate to restore normal breathing during sleep. Continuous positive airway pressure (CPAP) is the major treatment for SDB in heart failure, especially if obstructive rather than central sleep apnea (CSA) predominates. Adequate suppression of CSA by PAP is associated with a heart transplant-free survival benefit, although randomized trials are ongoing. Bilevel PAP (BPAP) may be as effective as CPAP in treating SDB and may be preferable over CPAP in patients who experience expiratory pressure discomfort. Adaptive (or auto) servo-ventilation (ASV), which adjusts the PAP depending on the patient’s airflow or tidal volume, may be useful in congestive heart failure patients if CPAP is ineffective. Other therapies that have been proposed for SDB in congestive heart failure include nocturnal oxygen, CO2 administration (by adding dead space), theophylline, and acetazolamide; most of which have not been systematically studied in outcome-based prospective randomized trials. PMID:21894522
Zhang, Miao; Bommer, Martin; Chatterjee, Ruchira; Hussein, Rana; Yano, Junko; Dau, Holger; Kern, Jan; Dobbek, Holger; Zouni, Athina
2017-07-18
In plants, algae and cyanobacteria, Photosystem II (PSII) catalyzes the light-driven splitting of water at a protein-bound Mn 4 CaO 5 -cluster, the water-oxidizing complex (WOC). In the photosynthetic organisms, the light-driven formation of the WOC from dissolved metal ions is a key process because it is essential in both initial activation and continuous repair of PSII. Structural information is required for understanding of this chaperone-free metal-cluster assembly. For the first time, we obtained a structure of PSII from Thermosynechococcus elongatus without the Mn 4 CaO 5 -cluster. Surprisingly, cluster-removal leaves the positions of all coordinating amino acid residues and most nearby water molecules largely unaffected, resulting in a pre-organized ligand shell for kinetically competent and error-free photo-assembly of the Mn 4 CaO 5 -cluster. First experiments initiating (i) partial disassembly and (ii) partial re-assembly after complete depletion of the Mn 4 CaO 5 -cluster agree with a specific bi-manganese cluster, likely a di-µ-oxo bridged pair of Mn(III) ions, as an assembly intermediate.
Early myeloid lineage choice is not initiated by random PU.1 to GATA1 protein ratios.
Hoppe, Philipp S; Schwarzfischer, Michael; Loeffler, Dirk; Kokkaliaris, Konstantinos D; Hilsenbeck, Oliver; Moritz, Nadine; Endele, Max; Filipczyk, Adam; Gambardella, Adriana; Ahmed, Nouraiz; Etzrodt, Martin; Coutu, Daniel L; Rieger, Michael A; Marr, Carsten; Strasser, Michael K; Schauberger, Bernhard; Burtscher, Ingo; Ermakova, Olga; Bürger, Antje; Lickert, Heiko; Nerlov, Claus; Theis, Fabian J; Schroeder, Timm
2016-07-14
The mechanisms underlying haematopoietic lineage decisions remain disputed. Lineage-affiliated transcription factors with the capacity for lineage reprogramming, positive auto-regulation and mutual inhibition have been described as being expressed in uncommitted cell populations. This led to the assumption that lineage choice is cell-intrinsically initiated and determined by stochastic switches of randomly fluctuating cross-antagonistic transcription factors. However, this hypothesis was developed on the basis of RNA expression data from snapshot and/or population-averaged analyses. Alternative models of lineage choice therefore cannot be excluded. Here we use novel reporter mouse lines and live imaging for continuous single-cell long-term quantification of the transcription factors GATA1 and PU.1 (also known as SPI1). We analyse individual haematopoietic stem cells throughout differentiation into megakaryocytic-erythroid and granulocytic-monocytic lineages. The observed expression dynamics are incompatible with the assumption that stochastic switching between PU.1 and GATA1 precedes and initiates megakaryocytic-erythroid versus granulocytic-monocytic lineage decision-making. Rather, our findings suggest that these transcription factors are only executing and reinforcing lineage choice once made. These results challenge the current prevailing model of early myeloid lineage choice.
12 CFR 1022.73 - Content, form, and timing of risk-based pricing notices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... an auto dealer or other party that is not affiliated with the person, any requirement to provide a... have the auto dealer or other party provide a notice described in §§ 1022.72(a), 1022.74(e), or 1022.74... procedures to verify that the auto dealer or other party provides such notice to the consumer within the...
46 CFR 35.20-45 - Use of Auto Pilot-T/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 1 2011-10-01 2011-10-01 false Use of Auto Pilot-T/ALL. 35.20-45 Section 35.20-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Navigation § 35.20-45 Use of Auto Pilot—T/ALL. Except as provided in 33 CFR 164.13, when the automatic pilot is used in: (a) Areas...
46 CFR 35.20-45 - Use of Auto Pilot-T/ALL.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 1 2014-10-01 2014-10-01 false Use of Auto Pilot-T/ALL. 35.20-45 Section 35.20-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Navigation § 35.20-45 Use of Auto Pilot—T/ALL. Except as provided in 33 CFR 164.13, when the automatic pilot is used in: (a) Areas...
12 CFR 222.73 - Content, form, and timing of risk-based pricing notices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... an auto dealer or other party that is not affiliated with the person, any requirement to provide a... have the auto dealer or other party provide a notice described in §§ 222.72(a), 222.74(e), or 222.74(f... procedures to verify that the auto dealer or other party provides such notice to the consumer within the...
46 CFR 35.20-45 - Use of Auto Pilot-T/ALL.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 1 2013-10-01 2013-10-01 false Use of Auto Pilot-T/ALL. 35.20-45 Section 35.20-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Navigation § 35.20-45 Use of Auto Pilot—T/ALL. Except as provided in 33 CFR 164.13, when the automatic pilot is used in: (a) Areas...
12 CFR 1022.73 - Content, form, and timing of risk-based pricing notices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... an auto dealer or other party that is not affiliated with the person, any requirement to provide a... have the auto dealer or other party provide a notice described in §§ 1022.72(a), 1022.74(e), or 1022.74... procedures to verify that the auto dealer or other party provides such notice to the consumer within the...
46 CFR 35.20-45 - Use of Auto Pilot-T/ALL.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 1 2012-10-01 2012-10-01 false Use of Auto Pilot-T/ALL. 35.20-45 Section 35.20-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Navigation § 35.20-45 Use of Auto Pilot—T/ALL. Except as provided in 33 CFR 164.13, when the automatic pilot is used in: (a) Areas...
Computing Mass Properties From AutoCAD
NASA Technical Reports Server (NTRS)
Jones, A.
1990-01-01
Mass properties of structures computed from data in drawings. AutoCAD to Mass Properties (ACTOMP) computer program developed to facilitate quick calculations of mass properties of structures containing many simple elements in such complex configurations as trusses or sheet-metal containers. Mathematically modeled in AutoCAD or compatible computer-aided design (CAD) system in minutes by use of three-dimensional elements. Written in Microsoft Quick-Basic (Version 2.0).
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-12
... and above that add liquidity in the Automatic Execution mode of order interaction (``AutoEx'').\\3\\ \\3... displayed orders in Tape A and C securities priced one dollar and above that add liquidity in AutoEx, the... that add liquidity in AutoEx if such ETP Holder's Liquidity Adding ADV is less than 20 basis points of...
46 CFR 35.20-45 - Use of Auto Pilot-T/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Use of Auto Pilot-T/ALL. 35.20-45 Section 35.20-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Navigation § 35.20-45 Use of Auto Pilot—T/ALL. Except as provided in 33 CFR 164.13, when the automatic pilot is used in: (a) Areas...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-08
... of interaction (``Auto-Ex Mode'') \\5\\ to remove liquidity in a security that is priced at or above $1....11(c)(13). See also SR-NSX-2013-07. \\5\\ Under Auto-Ex mode the Exchange matches and executes like... a Midpoint-Seeker Order in the Exchange's Auto-Ex Mode to remove liquidity in a security that is...
AutoCAD-To-NASTRAN Translator Program
NASA Technical Reports Server (NTRS)
Jones, A.
1989-01-01
Program facilitates creation of finite-element mathematical models from geometric entities. AutoCAD to NASTRAN translator (ACTON) computer program developed to facilitate quick generation of small finite-element mathematical models for use with NASTRAN finite-element modeling program. Reads geometric data of drawing from Data Exchange File (DXF) used in AutoCAD and other PC-based drafting programs. Written in Microsoft Quick-Basic (Version 2.0).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, K; Chang, X; Wang, J
Purpose: To evaluate whether Auto-Planning based volumetric-modulated radiotherapy (auto-VMAT) can reduce manual interaction time during treatment planning and improve plan quality for rectal cancer radiotherapy. Methods: Ten rectal cancer patients (stage II and III) after radical resection using Dixon surgery were enrolled. All patients were treated with VMAT technique. The manual VMAT plans (man-VMAT) were designed in the Pinnacle treatment planning system (Version 9.10) following the standard treatment planning procedure developed in our department. Clinical plans were manually designed by our experienced dosimetrists. Additionally, an auto-VMAT plan was created for each patient using Auto-Planning module. However, manual interaction was stillmore » applied to meet the clinical requirements. The treatment planning time and plan quality surrogated by the DVH parameters were compared between manual and automated plans. Results: The total planning time and manual interaction time were 50.38 and 4.47 min for the auto-VMAT and 36.81 and 16.94 min for the man-VMAT (t=60.14,−23.86; p=0.000, 0.000). In terms of plan quality, both plans meet the clinical requirements. The PTV homogeneity index (HI) and conformity index (CI) were 0.054 and 0.822 for the auto-VMAT and 0.059 and 0.815 for the man-VMAT (t=−1.72, 0.36;p=0.119,0.730).Compared to the man-VMAT, the auto-VMAT showed reduction of 11.9% and 0.7% in V40 and V50 of the bladder, respectively.The V30 and D mean were reduced by 14.0% and 5.1Gy in the left femur and 12.2% and 3.8Gy in the right femur. Conclusion: The Auto-Planning based VMAT plans not only shows similar or superior plan quality to the manual ones in the rectal cancer radiotherapy, but also improve the planning efficiency significantly. However, manual interactions are still required to achieve a clinically acceptable plan based on our experiences.« less
Boos, Anja M; Loew, Johanna S; Deschler, Gloria; Arkudas, Andreas; Bleiziffer, Oliver; Gulle, Heinz; Dragu, Adrian; Kneser, Ulrich; Horch, Raymund E; Beier, Justus P
2011-06-01
Bone tissue engineering approaches increasingly focus on the use of mesenchymal stem cells (MSC). In most animal transplantation models MSC are isolated and expanded before auto cell transplantation which might be critical for clinical application in the future. Hence this study compares the potential of directly auto-transplanted versus in vitro expanded MSC with or without bone morphogenetic protein-2 (BMP-2) to induce bone formation in a large volume ceramic bone substitute in the sheep model. MSC were isolated from bone marrow aspirates and directly auto-transplanted or expanded in vitro and characterized using fluorescence activated cell sorting (FACS) and RT-PCR analysis before subcutaneous implantation in combination with BMP-2 and β-tricalcium phosphate/hydroxyapatite (β-TCP/HA) granules. Constructs were explanted after 1 to 12 weeks followed by histological and RT-PCR evaluation. Sheep MSC were CD29(+), CD44(+) and CD166(+) after selection by Ficoll gradient centrifugation, while directly auto-transplanted MSC-populations expressed CD29 and CD166 at lower levels. Both, directly auto-transplanted and expanded MSC, were constantly proliferating and had a decreasing apoptosis over time in vivo. Directly auto-transplanted MSC led to de novo bone formation in a heterotopic sheep model using a β-TCP/HA matrix comparable to the application of 60 μg/ml BMP-2 only or implantation of expanded MSC. Bone matrix proteins were up-regulated in constructs following direct auto-transplantation and in expanded MSC as well as in BMP-2 constructs. Up-regulation was detected using immunohistology methods and RT-PCR. Dense vascularization was demonstrated by CD31 immunohistology staining in all three groups. Ectopic bone could be generated using directly auto-transplanted or expanded MSC with β-TCP/HA granules alone. Hence BMP-2 stimulation might become dispensable in the future, thus providing an attractive, clinically feasible approach to bone tissue engineering. © 2011 The Authors Journal of Cellular and Molecular Medicine © 2011 Foundation for Cellular and Molecular Medicine/Blackwell Publishing Ltd.
2014-01-01
Summary Objectives This paper presents the history of data system development steps (1964 – 1986) for the clinical analyzers AutoChemist®, and its successor AutoChemist PRISMA® (PRogrammable Individually Selective Modular Analyzer). The paper also partly recounts the history of development steps of the minicomputer PDP 8 from Digital Equipment. The first PDP 8 had 4 core memory boards of 1 K each and was large as a typical oven baking sheet and about 10 years later, PDP 8 was a “one chip microcomputer” with a 32 K memory chip. The fast developments of PDP 8 come to have a strong influence on the development of the data system for AutoChemist. Five major releases of the software were made during this period (1-5 MIACH). Results The most important aims were not only to calculate the results, but also be able to monitor their quality and automatically manage the orders, store the results in digital form for later statistical analysis and distribute the results to the physician in charge of the patient using thesame computer as the analyzer. Another result of the data system was the ability to customize AutoChemist to handle sample identification by using bar codes and the presentation of results to different types of laboratories. Conclusions Digital Equipment launched the PDP 8 just as a new minicomputer was desperately needed. No other known alternatives were available at the time. This was to become a key success factor for AutoChemist. That the AutoChemist with such a high capacity required a computer for data collection was obvious already in the early 1960s. That computer development would be so rapid and that one would be able to accomplish so much with a data system was even suspicious at the time. In total, 75; AutoChemist (31) and PRISMA (44) were delivered Worldwide The last PRISMA was delivered in 1987 to the Veteran Hospital Houston, TX USA PMID:24853032
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nourzadeh, H; Watkins, W; Siebers, J
Purpose: To determine if auto-contour and manual-contour—based plans differ when evaluated with respect to probabilistic coverage metrics and biological model endpoints for prostate IMRT. Methods: Manual and auto-contours were created for 149 CT image sets acquired from 16 unique prostate patients. A single physician manually contoured all images. Auto-contouring was completed utilizing Pinnacle’s Smart Probabilistic Image Contouring Engine (SPICE). For each CT, three different 78 Gy/39 fraction 7-beam IMRT plans are created; PD with drawn ROIs, PAS with auto-contoured ROIs, and PM with auto-contoured OARs with the manually drawn target. For each plan, 1000 virtual treatment simulations with different sampledmore » systematic errors for each simulation and a different sampled random error for each fraction were performed using our in-house GPU-accelerated robustness analyzer tool which reports the statistical probability of achieving dose-volume metrics, NTCP, TCP, and the probability of achieving the optimization criteria for both auto-contoured (AS) and manually drawn (D) ROIs. Metrics are reported for all possible cross-evaluation pairs of ROI types (AS,D) and planning scenarios (PD,PAS,PM). Bhattacharyya coefficient (BC) is calculated to measure the PDF similarities for the dose-volume metric, NTCP, TCP, and objectives with respect to the manually drawn contour evaluated on base plan (D-PD). Results: We observe high BC values (BC≥0.94) for all OAR objectives. BC values of max dose objective on CTV also signify high resemblance (BC≥0.93) between the distributions. On the other hand, BC values for CTV’s D95 and Dmin objectives are small for AS-PM, AS-PD. NTCP distributions are similar across all evaluation pairs, while TCP distributions of AS-PM, AS-PD sustain variations up to %6 compared to other evaluated pairs. Conclusion: No significant probabilistic differences are observed in the metrics when auto-contoured OARs are used. The prostate auto-contour needs improvement to achieve clinically equivalent plans.« less
Systemic Delivery of Atropine Sulfate by the MicroDose Dry-Powder Inhaler
Venkataramanan, R.; Hoffman, R.M.; George, M.P.; Petrov, A.; Richards, T.; Zhang, S.; Choi, J.; Gao, Y.Y.; Oakum, C.D.; Cook, R.O.; Donahoe, M.
2013-01-01
Abstract Background Inhaled atropine is being developed as a systemic and pulmonary treatment for the extended recovery period after chemical weapons exposure. We performed a pharmacokinetics study comparing inhaled atropine delivery using the MicroDose Therapeutx Dry Powder Inhaler (DPIA) with intramuscular (IM) atropine delivery via auto-injector (AUTO). Methods The MicroDose DPIA utilizes a novel piezoelectric system to aerosolize drug and excipient from a foil dosing blister. Subjects inhaled a 1.95-mg atropine sulfate dose from the dry powder inhaler on one study day [5 doses×0.4 mg per dose (nominal) delivered over 12 min] and received a 2-mg IM injection via the AtroPen® auto-injector on another. Pharmacokinetics, pharmacodynamic response, and safety were studied for 12 hr. Results A total of 17 subjects were enrolled. All subjects completed IM dosing. One subject did not perform inhaled delivery due to a skin reaction from the IM dose. Pharmacokinetic results were as follows: area under the curve concentration, DPIA=20.1±5.8, AUTO=23.7±4.9 ng hr/mL (means±SD); maximum concentration reached, DPIA=7.7±3.5, AUTO=11.0±3.8 ng/mL; time to reach maximum concentration, DPIA=0.25±0.47, AUTO=0.19±0.23 hr. Pharmacodynamic results were as follows: maximum increase in heart rate, DPIA=18±12, AUTO=23±13 beats/min; average change in 1-sec forced expiratory volume at 30 min, DPIA=0.16±0.22 L, AUTO=0.11±0.29 L. The relative bioavailability for DPIA was 87% (based on output dose). Two subjects demonstrated allergic responses: one to the first dose (AUTO), which was mild and transient, and one to the second dose (DPIA), which was moderate in severity, required treatment with oral and intravenous (IV) diphenhydramine and IV steroids, and lasted more than 7 days. Conclusions Dry powder inhalation is a highly bioavailable route for attaining rapid and consistent systemic concentrations of atropine. PMID:22691110