Unintentional Epinephrine Auto-injector Injuries: A National Poison Center Observational Study.
Anshien, Marco; Rose, S Rutherfoord; Wills, Brandon K
2016-11-24
Epinephrine is the only first-line therapeutic agent used to treat life-threatening anaphylaxis. Epinephrine auto-injectors are commonly carried by patients at risk for anaphylaxis, and reported cases of unintentional auto-injector injury have increased over the last decade. Modifications of existing designs and release of a new style of auto-injector are intended to reduce epinephrine auto-injector misuse. The aim of the study was to characterize reported cases of unintentional epinephrine auto-injector exposures from 2013 to 2014 and compare demographics, auto-injector model, and anatomical site of such exposures. The American Association of Poison Control Center's National Poison Data System was searched from January 1, 2013, to December 31, 2014, for cases of unintentional epinephrine auto-injector exposures. Anatomical site data were obtained from all cases reported to the Virginia Poison Center and participating regional poison center for Auvi-Q cases. A total of 6806 cases of unintentional epinephrine auto-injector exposures were reported to US Poison Centers in 2013 and 2014. Of these cases, 3933 occurred with EpiPen, 2829 with EpiPen Jr, 44 with Auvi-Q, and no case reported of Adrenaclick. The most common site of unintentional injection for traditional epinephrine auto-injectors was the digit or thumb, with 58% of cases for EpiPen and 39% of cases with EpiPen Jr. With Auvi-Q, the most common site was the leg (78% of cases). The number of unintentional epinephrine auto-injector cases reported to American Poison Centers in 2013-2014 has increased compared with previous data. Most EpiPen exposures were in the digits, whereas Auvi-Q was most frequently in the leg. Because of the limitations of Poison Center data, more research is needed to identify incidence of unintentional exposures and the effectiveness of epinephrine auto-injector redesign.
Genotoxic damage in auto body shop workers.
Siebel, Anna Maria; Basso da Silva, Luciano
2010-10-01
Some studies have shown increased DNA damage among car painters, but other professionals working in auto body and paint shops have not been extensively assessed. The aim of this study was to assess DNA damage in different types of auto body shop workers by measuring micronucleus (MN) levels in exfoliated buccal cells. The mean number of cells with MN per 2000 exfoliated buccal cells was analyzed in three groups of male workers: auto body repair technicians, painters, and office workers (control group). All participants answered a questionnaire inquiring about age, smoking habits, alcohol consumption, work practices, occupational exposure time, job activities, and use of protective equipment. The mean number of cells with MN was 3.50 ± 1.50 in auto body painters, 3.91 ± 2.10 in auto body repair technicians, and 0.80 ± 0.78 in office workers, with a significant difference between the control group and the two other groups (p = 0.0001). Age, occupational exposure time, use of protective masks, alcohol consumption, and smoking habit did not affect MN results. The findings indicate that technicians and painters working in auto body shops are at risk for genotoxic damage, while office workers seem to be protected.
Lowering transit crime may save energy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Shifting travelers from less-energy-efficient automobiles to more-energy-efficient transit vehicles is an essential energy conservation measure. During peak travel periods the average auto carries 1.4 persons and consumes 16 times more fuel per passenger mile than an urban bus carrying an average of 75 passengers. Today's travelers are using transit for less than 3 percent of their urban trips. Travelers reject transit because its costs--in terms of time, money, and quality of service--are higher than those for the auto. One element of the higher cost of using transit is the increased exposure to crime which occurs when a traveler shifts frommore » his private car to mass transit. The increased exposure is the result of the additional time transit travelers spend getting to and waiting at transit stops, as well as the additional time spent riding, and the lack of privacy while on transit. Furthermore, transit travelers have no control over their route, which may go through high-crime areas. In contrast, traveling by auto not only eliminates the time getting to and waiting at transit stops, but it also provides a secure compartment which can be locked. Traveling companions can be chosen to limit exposure to crime. In addition, auto travel provides the opportunity to select the safest and shortest route. Between the two extremes of high exposure to crime presented by public transit and low exposure to crime offered by private autos lies para-transit, such as taxis, carpools, and jitneys (small buses that carry passengers over a regular route according to a flexible schedule). (MCW)« less
Arrandale, Victoria; Meijster, Tim; Pronk, Anjoeka; Doekes, Gert; Redlich, Carrie A; Holness, D Linn; Heederik, Dick
2013-02-01
Despite the importance of skin exposure, studies of skin symptoms in relation to exposure and respiratory symptoms are rare. The goals of this study were to describe exposure-response relationships for skin symptoms, and to investigate associations between skin and respiratory symptoms in bakery and auto body shop workers. Data from previous studies of bakery and auto body shop workers were analyzed. Average exposure estimates for wheat allergen and isocyanates were used. Generalized linear models were constructed to describe the relationships between exposure and skin symptoms, as well as between skin and respiratory symptoms. Data from 723 bakery and 473 auto body shop workers were analyzed. In total, 5.3% of bakery and 6.1% of auto body shop workers were female; subjects' mean age was 39 and 38 years, respectively. Exposure-response relationships were observed in auto body shop workers for itchy or dry skin (PR 1.55, 95% CI 1.2-2.0) and work-related itchy skin (PR 1.97, 95% CI 1.2-3.3). A possible exposure-response relationship for work-related itchy skin in bakery workers did not reach statistical significance. In both groups, reporting skin symptoms was strongly and significantly associated with reporting respiratory symptoms, both work-related and non-work-related. Exposure-response relationships were observed for skin symptoms in auto body shop workers. The lack of significant exposure-response associations in bakery workers should be interpreted cautiously. Workers who reported skin symptoms were up to four times more likely to report respiratory symptoms. Improved awareness of both skin and respiratory outcomes in exposed workers is needed.
Occupational noise-induced hearing loss in auto part factory workers in welding units in Thailand.
Sriopas, Apiradee; Chapman, Robert S; Sutammasa, Saravudh; Siriwong, Wattasit
2017-01-24
Most workers in auto part factories in Thailand are usually exposed to excessive noise in their workplace. This study aimed to assess the level of occupational noise-induced hearing loss and investigate risk factors causing hearing loss in auto part factory workers in the welding units in Thailand. This was a cross-sectional study. One hundred eighty subjects were recruited from 356 workers in the welding unit of three factories. Sixty eligible subjects in each factory were selected by systemic random sampling. The subjects were interviewed using a face-to-face questionnaire. Noise exposure levels and audiograms were measured by a noise dosimeter and an audiometer, respectively. The findings confirmed that noise exposure levels of 86-90 dB (A) and exceeding 90 dB (A) significantly increased the risk of hearing loss in either ear. A noise exposure level exceeding 90 dB (A) significantly increased the prevalence of hearing loss in both ears. Regarding, a 10-pack-year smoking history increased the prevalence of hearing loss in either ear or both ears. In addition, subjects with employment duration exceeding 10 years significantly developed hearing loss in either ear. The engineering control or personal control by wearing hearing protection device should be used to decrease noise exposure levels lower than 85 dB (A) for 8 h. Moreover, if the exposure level reaches 85 dB (A) for 8 h, the employer needs to implement a hearing conservation program in the workplace.
Determinants of isocyanate exposures in auto body repair and refinishing shops.
Woskie, S R; Sparer, J; Gore, R J; Stowe, M; Bello, D; Liu, Y; Youngs, F; Redlich, C; Eisen, E; Cullen, M
2004-07-01
As part of the Survey of Painters and Repairers of Auto bodies by Yale (SPRAY), the determinants of isocyanate exposure in auto body repair shops were evaluated. Measurements (n = 380) of hexamethylene diisocyanate-based monomer and polyisocyanate and isophorone diisocyanate-based polyisocyanate were collected from 33 auto body shops. The median total reactive isocyanate concentrations expressed as mass concentration of the NCO functional group were: 206 microg NCO/m3 for spray operations; 0.93 microg NCO/m3 for samples collected in the vicinity of spray operations done on the shop floor (near spray); 0.05 microg NCO/m3 for office or other shop areas adjacent to spray areas (workplace background); 0.17 microg NCO/m3 for paint mixing and gun cleaning operations (mixing); 0.27 microg NCO/m3 for sanding operations. Exposure determinants for the sample NCO mass load were identified using linear regression, tobit regression and logistic regression models. For spray samples in a spray booth the significant determinants were the number of milliliters of NCO applied, the gallons of clear coat used by the shop each month and the type of spray booth used (custom built crossdraft, prefabricated crossdraft or downdraft/semi-downdraft). For near spray (bystander) samples, outdoor temperature >65 degrees F (18 degrees C) and shop size >5000 feet2 (465 m2) were significant determinants of exposure levels. For workplace background samples the shop annual income was the most important determinant. For sanding samples, the shop annual income and outdoor temperature >65 degrees F (18 degrees C) were the most significant determinants. Identification of these key exposure determinants will be useful in targeting exposure evaluation and control efforts to reduce isocyanate exposures.
Face detection assisted auto exposure: supporting evidence from a psychophysical study
NASA Astrophysics Data System (ADS)
Jin, Elaine W.; Lin, Sheng; Dharumalingam, Dhandapani
2010-01-01
Face detection has been implemented in many digital still cameras and camera phones with the promise of enhancing existing camera functions (e.g. auto exposure) and adding new features to cameras (e.g. blink detection). In this study we examined the use of face detection algorithms in assisting auto exposure (AE). The set of 706 images, used in this study, was captured using Canon Digital Single Lens Reflex cameras and subsequently processed with an image processing pipeline. A psychophysical study was performed to obtain optimal exposure along with the upper and lower bounds of exposure for all 706 images. Three methods of marking faces were utilized: manual marking, face detection algorithm A (FD-A), and face detection algorithm B (FD-B). The manual marking method found 751 faces in 426 images, which served as the ground-truth for face regions of interest. The remaining images do not have any faces or the faces are too small to be considered detectable. The two face detection algorithms are different in resource requirements and in performance. FD-A uses less memory and gate counts compared to FD-B, but FD-B detects more faces and has less false positives. A face detection assisted auto exposure algorithm was developed and tested against the evaluation results from the psychophysical study. The AE test results showed noticeable improvement when faces were detected and used in auto exposure. However, the presence of false positives would negatively impact the added benefit.
Ghio, Andrew J; Sangani, Rahul G; Brighton, Luisa E; Carson, John L
2010-06-01
Macrophages from smokers demonstrate an increased auto-fluorescence. Similarly, auto-fluorescence follows in vitro exposure of macrophages to cigarette smoke condensate (i.e., the particulate fraction of cigarette smoke). The composition of particles in cigarette smoke can be comparable to air pollution particles. We tested the postulate that macrophages exposed to air pollution particles could demonstrate auto-fluorescence. Healthy nonsmoking and healthy smoking volunteers (both 18-40 years of age) underwent fiberoptic bronchoscopy with bronchoalveolar lavage and alveolar macrophages isolated. Macrophages were incubated at 37 degrees C in 5% CO(2) with either PBS or 100 microg/mL particle for both 1 and 24 h. Particles included a residual oil fly ash, Mt. St. Helens volcanic ash, and ambient air particles collected from St. Louis, Missouri and Salt Lake City, Utah. At the end of incubation, 50 microL of the cell suspension was cytocentrifuged and examined at modes for viewing fluorescein isothiocyanate (FITC) and rhodamine fluorescence. Both emission source air pollution particles demonstrated FITC and rhodamine auto-fluorescence at 1 and 24 h, but the signal following incubation of the macrophages with oil fly ash appeared greater. Similarly, the ambient particles were associated with auto-fluorescence by the alveolar macrophages and this appeared to be dose-dependent. We conclude that exposure of macrophages to air pollution particles can be associated with auto-fluorescence in the FITC and rhodamine modes. c) 2009 Wiley-Liss, Inc
Kamal, Izdihar; Chelliah, Kanaga K; Mustafa, Nawal
2015-05-01
The aim of this research was to examine the average glandular dose (AGD) of radiation among different breast compositions of glandular and adipose tissue with auto-modes of exposure factor selection in digital breast tomosynthesis. This experimental study was carried out in the National Cancer Society, Kuala Lumpur, Malaysia, between February 2012 and February 2013 using a tomosynthesis digital mammography X-ray machine. The entrance surface air kerma and the half-value layer were determined using a 100H thermoluminescent dosimeter on 50% glandular and 50% adipose tissue (50/50) and 20% glandular and 80% adipose tissue (20/80) commercially available breast phantoms (Computerized Imaging Reference Systems, Inc., Norfolk, Virginia, USA) with auto-time, auto-filter and auto-kilovolt modes. The lowest AGD for the 20/80 phantom with auto-time was 2.28 milliGray (mGy) for two dimension (2D) and 2.48 mGy for three dimensional (3D) images. The lowest AGD for the 50/50 phantom with auto-time was 0.97 mGy for 2D and 1.0 mGy for 3D. The AGD values for both phantoms were lower against a high kilovolt peak and the use of auto-filter mode was more practical for quick acquisition while limiting the probability of operator error.
Kobayashi, Masanao; Asada, Yasuki; Matsubara, Kosuke; Suzuki, Shouichi; Matsunaga, Yuta; Haba, Tomonobu; Kawaguchi, Ai; Daioku, Tomihiko; Toyama, Hiroshi; Kato, Ryoichi
2017-05-01
Adequate dose management during computed tomography is important. In the present study, the dosimetric application software ImPACT was added to a functional calculator of the size-specific dose estimate and was part of the scan settings for the auto exposure control (AEC) technique. This study aimed to assess the practicality and accuracy of the modified ImPACT software for dose estimation. We compared the conversion factors identified by the software with the values reported by the American Association of Physicists in Medicine Task Group 204, and we noted similar results. Moreover, doses were calculated with the AEC technique and a fixed-tube current of 200 mA for the chest-pelvis region. The modified ImPACT software could estimate each organ dose, which was based on the modulated tube current. The ability to perform beneficial modifications indicates the flexibility of the ImPACT software. The ImPACT software can be further modified for estimation of other doses. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Torres, Juan; Menéndez, José Manuel
2015-02-01
This paper establishes a real-time auto-exposure method to guarantee that surveillance cameras in uncontrolled light conditions take advantage of their whole dynamic range while provide neither under nor overexposed images. State-of-the-art auto-exposure methods base their control on the brightness of the image measured in a limited region where the foreground objects are mostly located. Unlike these methods, the proposed algorithm establishes a set of indicators based on the image histogram that defines its shape and position. Furthermore, the location of the objects to be inspected is likely unknown in surveillance applications. Thus, the whole image is monitored in this approach. To control the camera settings, we defined a parameters function (Ef ) that linearly depends on the shutter speed and the electronic gain; and is inversely proportional to the square of the lens aperture diameter. When the current acquired image is not overexposed, our algorithm computes the value of Ef that would move the histogram to the maximum value that does not overexpose the capture. When the current acquired image is overexposed, it computes the value of Ef that would move the histogram to a value that does not underexpose the capture and remains close to the overexposed region. If the image is under and overexposed, the whole dynamic range of the camera is therefore used, and a default value of the Ef that does not overexpose the capture is selected. This decision follows the idea that to get underexposed images is better than to get overexposed ones, because the noise produced in the lower regions of the histogram can be removed in a post-processing step while the saturated pixels of the higher regions cannot be recovered. The proposed algorithm was tested in a video surveillance camera placed at an outdoor parking lot surrounded by buildings and trees which produce moving shadows in the ground. During the daytime of seven days, the algorithm was running alternatively together with a representative auto-exposure algorithm in the recent literature. Besides the sunrises and the nightfalls, multiple weather conditions occurred which produced light changes in the scene: sunny hours that produced sharpen shadows and highlights; cloud coverages that softened the shadows; and cloudy and rainy hours that dimmed the scene. Several indicators were used to measure the performance of the algorithms. They provided the objective quality as regards: the time that the algorithms recover from an under or over exposure, the brightness stability, and the change related to the optimal exposure. The results demonstrated that our algorithm reacts faster to all the light changes than the selected state-of-the-art algorithm. It is also capable of acquiring well exposed images and maintaining the brightness stable during more time. Summing up the results, we concluded that the proposed algorithm provides a fast and stable auto-exposure method that maintains an optimal exposure for video surveillance applications. Future work will involve the evaluation of this algorithm in robotics.
Vehicle occupant exposure to carbon monoxide.
Koushki, P A; al-Dhowalia, K H; Niaizi, S A
1992-12-01
This paper focuses on the auto commuting micro-environment and presents typical carbon monoxide (CO) concentrations to which auto commuters in central Riyadh, Saudi Arabia were exposed. Two test vehicles traveling over four main arterial roadways were monitored for inside and outside CO levels during eighty peak and off-peak hours extending over an eight-month period. The relative importance of several variables which explained the variability in CO concentrations inside autos was also assessed. It was found that during peak hours auto commuters were exposed to mean CO levels that ranged from 30 to 40 ppm over trips that typically took between 25 to 40 minutes. The mean ratio of inside to outside CO levels was 0.84. Results of variance component analyses indicated that the most important variables affecting CO concentrations inside autos were, in addition to the smoking of vehicle occupants, traffic volume, vehicle speed, period of day and wind velocity. An increase in traffic volume from 1,000 to 5,000 vehicles per hour (vph) increased mean CO level exposure by 71 percent. An increase in vehicle speed from 14 to 55 km/h reduced mean CO exposure by 36 percent. The number of traffic interruptions had a moderate effect on mean concentrations of CO inside vehicles.
Automatic brightness control of laser spot vision inspection system
NASA Astrophysics Data System (ADS)
Han, Yang; Zhang, Zhaoxia; Chen, Xiaodong; Yu, Daoyin
2009-10-01
The laser spot detection system aims to locate the center of the laser spot after long-distance transmission. The accuracy of positioning laser spot center depends very much on the system's ability to control brightness. In this paper, an automatic brightness control system with high-performance is designed using the device of FPGA. The brightness is controlled by combination of auto aperture (video driver) and adaptive exposure algorithm, and clear images with proper exposure are obtained under different conditions of illumination. Automatic brightness control system creates favorable conditions for positioning of the laser spot center later, and experiment results illuminate the measurement accuracy of the system has been effectively guaranteed. The average error of the spot center is within 0.5mm.
[Advances in research on automatic exposure control of mammography system].
Wang, Guoyi; Ye, Chengfu; Wu, Haiming; Wang, Tainfu; Zhang, Hong
2014-12-01
Mammography imaging is one of the most demanding imaging modalities from the point of view of the bal- ance between image quality (the visibility of small size and/or low contrast structures) and dose (screening of many asymptomatic people). Therefore, since the introduction of the first dedicated mammographic units, many efforts have been directed to seek the best possible image quality while minimizing patient dose. The performance of auto- matic exposure control (AEC) is the manifestation of this demand. The theory of AEC includes exposure detection and optimization and also involves some accomplished methodology. This review presents the development and present situa- tion of spectrum optimization, detector evolution, and the way how to accomplish and evaluate AEC methods.
Real-time deblurring of handshake blurred images on smartphones
NASA Astrophysics Data System (ADS)
Pourreza-Shahri, Reza; Chang, Chih-Hsiang; Kehtarnavaz, Nasser
2015-02-01
This paper discusses an Android app for the purpose of removing blur that is introduced as a result of handshakes when taking images via a smartphone. This algorithm utilizes two images to achieve deblurring in a computationally efficient manner without suffering from artifacts associated with deconvolution deblurring algorithms. The first image is the normal or auto-exposure image and the second image is a short-exposure image that is automatically captured immediately before or after the auto-exposure image is taken. A low rank approximation image is obtained by applying singular value decomposition to the auto-exposure image which may appear blurred due to handshakes. This approximation image does not suffer from blurring while incorporating the image brightness and contrast information. The eigenvalues extracted from the low rank approximation image are then combined with those from the shortexposure image. It is shown that this deblurring app is computationally more efficient than the adaptive tonal correction algorithm which was previously developed for the same purpose.
Gardner, Renee M; Nyland, Jennifer F; Silva, Ines A; Ventura, Ana Maria; de Souza, Jose Maria; Silbergeld, Ellen K
2010-05-01
Mercury is an immunotoxic substance that has been shown to induce autoimmune disease in rodent models, characterized by lymphoproliferation, overproduction of immunoglobulin (IgG and IgE), and high circulating levels of auto-antibodies directed at antigens located in the nucleus (antinuclear auto-antibodies, or ANA) or the nucleolus (antinucleolar auto-antibodies, or ANoA). We have reported elevated levels of ANA and ANoA in human populations exposed to mercury in artisanal gold mining, though other confounding variables that may also modulate ANA/ANoA levels were not well controlled. The goal of this study is to specifically test whether occupational and environmental conditions (other than mercury exposure) that are associated with artisanal gold mining affect the prevalence of markers of autoimmune dysfunction. We measured ANA, ANoA, and cytokine concentrations in serum and compared results from mercury-exposed artisanal gold miners to those from diamond and emerald miners working under similar conditions and with similar socio-economic status and risks of infectious disease. Mercury-exposed gold miners had higher prevalence of detectable ANA and ANoA and higher titers of ANA and ANoA as compared to diamond and emerald miners with no occupational mercury exposure. Also, mercury-exposed gold miners with detectable ANA or ANoA in serum had significantly higher concentrations of pro-inflammatory cytokines IL-1beta, TNF-alpha, and IFN-gamma in serum as compared to the diamond and emerald miners. This study provides further evidence that mercury exposure may lead to autoimmune dysfunction and systemic inflammation in affected populations. Copyright 2010 Elsevier Inc. All rights reserved.
Urinary 1-Hydroxypyrene as a Biomarker to Carcinogenic Polycyclic Aromatic Hydrocarbon Exposure
Ifegwu, Clinton; Osunjaye, Kayode; Fashogbon, Folasade; Oke, Kolawole; Adeniyi, Afolabi; Anyakora, Chimezie
2012-01-01
In order to capture the extent of exposure to polycyclic aromatic hydrocarbons (PAHs), various biomarkers have been employed. The biomarkers employed for PAHs include PAHs genetoxic end points in lymphocytes, urinary metabolites, PAH-DNA adducts, and PAH-Protein adducts. Of these, excretory 1-hydroxypyene, a metabolite of pyrene, has been used extensively as a biological monitoring indicator of exposure to PAHs. This study attempts to assess the level of this biomarker in the body fluid of 68 exposed subjects using high performance liquid chromatography HPLC. The subjects screened included auto mechanics, drivers, and fuel attendants. 1-hydroxypyrene was extracted from the urine of the subjects using solid phase extraction method. The HPLC analysis was done in isocratic mode using water:methanol (12:88 v/v) mobile phase. The stationary phase was XBridge C18 (150 × 4.6 mm) 5 μm column. The wavelength was 250 nm at a flow rate of 1.2 mL/min. The oven temperature was 30 ºC and the injection volume was 20 μL. The run time was 3 minutes. The level of urinary 1-hydroxypyrene detected varied for the different categories of occupation studied. About 27% of sampled fuel attendants and 22% of auto mechanics had detectable 1-hydroxypyrene in their urine samples. There was no detectable 1-hydroxypyene in the urine samples of commercial drivers or in the urine samples of students used as controls. The results of this study showed that fuel attendants and auto mechanics have significant exposures to PAHs. So far, there is no established benchmark for level of PAHs in urine, but our findings indicate the possibility of future cancer cases in this population as a result of their occupational exposure. The study was not able to link the level of 1-hydroxypyene with the smoking habits of the subjects. PMID:24179391
Urinary 1-hydroxypyrene as a biomarker to carcinogenic polycyclic aromatic hydrocarbon exposure.
Ifegwu, Clinton; Osunjaye, Kayode; Fashogbon, Folasade; Oke, Kolawole; Adeniyi, Afolabi; Anyakora, Chimezie
2012-01-01
In order to capture the extent of exposure to polycyclic aromatic hydrocarbons (PAHs), various biomarkers have been employed. The biomarkers employed for PAHs include PAHs genetoxic end points in lymphocytes, urinary metabolites, PAH-DNA adducts, and PAH-Protein adducts. Of these, excretory 1-hydroxypyene, a metabolite of pyrene, has been used extensively as a biological monitoring indicator of exposure to PAHs. This study attempts to assess the level of this biomarker in the body fluid of 68 exposed subjects using high performance liquid chromatography HPLC. The subjects screened included auto mechanics, drivers, and fuel attendants. 1-hydroxypyrene was extracted from the urine of the subjects using solid phase extraction method. The HPLC analysis was done in isocratic mode using water:methanol (12:88 v/v) mobile phase. The stationary phase was XBridge C18 (150 × 4.6 mm) 5 μm column. The wavelength was 250 nm at a flow rate of 1.2 mL/min. The oven temperature was 30 ºC and the injection volume was 20 μL. The run time was 3 minutes. The level of urinary 1-hydroxypyrene detected varied for the different categories of occupation studied. About 27% of sampled fuel attendants and 22% of auto mechanics had detectable 1-hydroxypyrene in their urine samples. There was no detectable 1-hydroxypyene in the urine samples of commercial drivers or in the urine samples of students used as controls. The results of this study showed that fuel attendants and auto mechanics have significant exposures to PAHs. So far, there is no established benchmark for level of PAHs in urine, but our findings indicate the possibility of future cancer cases in this population as a result of their occupational exposure. The study was not able to link the level of 1-hydroxypyene with the smoking habits of the subjects.
Jo, W K; Park, K H
1998-01-01
This study was designed to allow systematic comparison of exposure on public (40-seater buses) and private (four passengers cars) transport modes for carbon monoxide (CO), methyl-tertiary butyl ether (MTBE), and benzene by carrying out simultaneous measurements along the same routes. There were statistically significant differences (p < 0.05) in the concentrations of all target compounds among the three microenvironments; inside autos; inside buses; and in ambient air. The target compounds were significantly correlated for all the three environments, with at least p < 0.05. The in-vehicle concentrations of MTBE and benzene were significantly higher (p < 0.0001), on the average 3.5 times higher, in the car with a carbureted engine than in the other three electronic fuel-injected cars. On the other hand, the CO concentrations were not significantly different among the four cars. The in-auto MTBE levels (48.5 micrograms/m3 as a median) measured during commutes in this study was 2-3 times higher than the New Jersey and Connecticut's results. The in-auto concentration of CO (4.8 ppm as a median) in this study was comparable with those in later studies in some American cities, but much lower than those in earlier studies in other American cities. The in-bus CO concentration was 3.6 ppm as a median. As a median, the in-auto concentration of benzene was 44.9 micrograms/m3, while the in-bus concentration 17.0 micrograms/m3. The in-auto/in-bus exposure ratios for all the target compounds was 31-40% higher than the corresponding concentration ratios, due to the higher travel speed on buses in the specified commute route as compared to the autos.
Orlenko, Alena; Moore, Jason H; Orzechowski, Patryk; Olson, Randal S; Cairns, Junmei; Caraballo, Pedro J; Weinshilboum, Richard M; Wang, Liewei; Breitenstein, Matthew K
2018-01-01
With the maturation of metabolomics science and proliferation of biobanks, clinical metabolic profiling is an increasingly opportunistic frontier for advancing translational clinical research. Automated Machine Learning (AutoML) approaches provide exciting opportunity to guide feature selection in agnostic metabolic profiling endeavors, where potentially thousands of independent data points must be evaluated. In previous research, AutoML using high-dimensional data of varying types has been demonstrably robust, outperforming traditional approaches. However, considerations for application in clinical metabolic profiling remain to be evaluated. Particularly, regarding the robustness of AutoML to identify and adjust for common clinical confounders. In this study, we present a focused case study regarding AutoML considerations for using the Tree-Based Optimization Tool (TPOT) in metabolic profiling of exposure to metformin in a biobank cohort. First, we propose a tandem rank-accuracy measure to guide agnostic feature selection and corresponding threshold determination in clinical metabolic profiling endeavors. Second, while AutoML, using default parameters, demonstrated potential to lack sensitivity to low-effect confounding clinical covariates, we demonstrated residual training and adjustment of metabolite features as an easily applicable approach to ensure AutoML adjustment for potential confounding characteristics. Finally, we present increased homocysteine with long-term exposure to metformin as a potentially novel, non-replicated metabolite association suggested by TPOT; an association not identified in parallel clinical metabolic profiling endeavors. While warranting independent replication, our tandem rank-accuracy measure suggests homocysteine to be the metabolite feature with largest effect, and corresponding priority for further translational clinical research. Residual training and adjustment for a potential confounding effect by BMI only slightly modified the suggested association. Increased homocysteine is thought to be associated with vitamin B12 deficiency - evaluation for potential clinical relevance is suggested. While considerations for clinical metabolic profiling are recommended, including adjustment approaches for clinical confounders, AutoML presents an exciting tool to enhance clinical metabolic profiling and advance translational research endeavors.
Jo, W K; Choi, S J
1996-08-01
This study identified in-auto and in-bus exposures to six selected aromatic volatile organic compounds (VOCs) for commutes on an urban-suburban route in Korea. A bus-service route was selected to include three segments of Taegu and one suburban segment (Hayang) to satisfy the criteria specified for this study. This study indicates that motor vehicle exhaust and evaporative emissions are major sources of both auto and bus occupants' exposures to aromatic VOCs in both Taegu and Hayang. A nonparametric statistical test (Wilcoxon test) showed that in-auto benzene levels were significantly different from in-bus benzene levels for both urban-segment and suburban-segment commutes. The test also showed that the benzene-level difference between urban-segment and suburban-segment commutes was significant for both autos and buses. An F-test showed the same statistical results for the comparison of the summed in-vehicle concentration of the six target VOCs (benzene, toluene, ethylbenzene, and o,m,p-xylenes) as those for the comparison of the in-vehicle benzene concentration. On the other hand, the in-vehicle benzene level only and the sum were not significantly different among the three urban-segment commutes and between the morning and evening commutes. The in-auto VOC concentrations were intermediate between the results for the Los Angeles and Boston. The in-bus VOC concentrations were about one-tenth of the Taipei, Taiwan results.
Stephen, Peter; Mahalakshmy, Thulasingam; Manju, Rajaram; Laksham, Karthik B; Subramani, Sudalai; Panda, Kanhu; Sarkar, Sonali
2018-01-01
Auto-rickshaw (three wheelers open cabin type of vehicle) drivers are exposed to traffic air pollution. Studies have demonstrated reduced pulmonary function among drivers. However, limited studies have determined the prevalence of chronic respiratory symptoms or chronic obstructive pulmonary disease (COPD) among drivers. Among auto-rickshaw drivers of urban Puducherry to determine prevalence of (i) chronic respiratory symptoms by using Indian Study on Epidemiology of Asthma, Respiratory Symptoms, and Chronic Bronchitis (INSEARCH) questionnaire and (ii) COPD by measuring peak expiratory flow rate (PEFR). Cross-sectional, descriptive study. Cluster random sampling was used to select 297 auto-rickshaw drivers. Subjects were interviewed using the INSEARCH questionnaire. PEFR was measured using Wright's peak flow meter. We also assessed exposure to tobacco smoke. Prevalence and 95% confidence interval of chronic respiratory symptoms and COPD were calculated. All the auto-rickshaw drivers were male, and 75% were in the age group of 31-50 years. They spend most of the time on the roadside either driving or waiting at the auto-stand. Prevalence of nonspecific respiratory symptoms among auto-rickshaw drivers was 76% (breathlessness on exertion 68%, cough at night and phlegm in the morning 22%, wheezing 18% assessed for last 12 months). Around 28% of them had PEFR <80%. The prevalence of tobacco smoking was also high (64%), and 100% had exposure to tobacco smoke at the workplace. The nonspecific chronic symptoms were high among auto-rickshaw drivers as compared to the general population noted from a multicentric study done in India. We recommend that auto-rickshaw drivers should use personal protective equipment and would require regular screening and treatment for respiratory impairment.
Stephen, Peter; Mahalakshmy, Thulasingam; Manju, Rajaram; Laksham, Karthik B.; Subramani, Sudalai; Panda, Kanhu; Sarkar, Sonali
2018-01-01
Context: Auto-rickshaw (three wheelers open cabin type of vehicle) drivers are exposed to traffic air pollution. Studies have demonstrated reduced pulmonary function among drivers. However, limited studies have determined the prevalence of chronic respiratory symptoms or chronic obstructive pulmonary disease (COPD) among drivers. Aims: Among auto-rickshaw drivers of urban Puducherry to determine prevalence of (i) chronic respiratory symptoms by using Indian Study on Epidemiology of Asthma, Respiratory Symptoms, and Chronic Bronchitis (INSEARCH) questionnaire and (ii) COPD by measuring peak expiratory flow rate (PEFR). Setting and Designs: Cross-sectional, descriptive study. Subjects and Methods: Cluster random sampling was used to select 297 auto-rickshaw drivers. Subjects were interviewed using the INSEARCH questionnaire. PEFR was measured using Wright's peak flow meter. We also assessed exposure to tobacco smoke. Statistical Analysis Used: Prevalence and 95% confidence interval of chronic respiratory symptoms and COPD were calculated. Results: All the auto-rickshaw drivers were male, and 75% were in the age group of 31–50 years. They spend most of the time on the roadside either driving or waiting at the auto-stand. Prevalence of nonspecific respiratory symptoms among auto-rickshaw drivers was 76% (breathlessness on exertion 68%, cough at night and phlegm in the morning 22%, wheezing 18% assessed for last 12 months). Around 28% of them had PEFR <80%. The prevalence of tobacco smoking was also high (64%), and 100% had exposure to tobacco smoke at the workplace. Conclusion: The nonspecific chronic symptoms were high among auto-rickshaw drivers as compared to the general population noted from a multicentric study done in India. We recommend that auto-rickshaw drivers should use personal protective equipment and would require regular screening and treatment for respiratory impairment. PMID:29743784
40 CFR 49.144 - Control equipment requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... remote notification system if the pilot flame fails. (B) An electronically controlled auto-ignition... emissions; (iv) The pit flare is equipped with an electronically controlled auto-ignition system with a... electronically controlled auto-ignition system must be repaired or replaced before the pit flare is utilized...
40 CFR 49.144 - Control equipment requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... remote notification system if the pilot flame fails. (B) An electronically controlled auto-ignition... emissions; (iv) The pit flare is equipped with an electronically controlled auto-ignition system with a... electronically controlled auto-ignition system must be repaired or replaced before the pit flare is utilized...
Operations Manual for the National Center for Physical Acoustics Infrasound Microphone
2013-02-01
thumbdrive.) There are three sections of the configuration file that can be edited: sensorConfig, adcConfig and autoControl . Modifying any other...for autoControl autoControl = { options = ( { doSchedule = 0; if nonzero, hourly scheduler is enabled
78 FR 23688 - Airworthiness Directives; Bell Helicopter Textron Canada Inc. Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-22
... would require replacing certain part-numbered engine auto-relight kit control boxes. This proposed AD is... range requirements, which could cause the control box to malfunction, disabling the engine auto-relight... helicopters with an engine auto-relight kit control box assembly (control box assembly) part number 206-375...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schetrit, Oren; Kim, Joyce; Yin, Rongxin
2014-08-01
Automated demand response (Auto-DR) is expected to close the loop between buildings and the grid by providing machine-to-machine communications to curtail loads without the need for human intervention. Hence, it can offer more reliable and repeatable demand response results to the grid than the manual approach and make demand response participation a hassle-free experience for customers. However, many building operators misunderstand Auto-DR and are afraid of losing control over their building operation. To ease the transition from manual to Auto-DR, we designed and implemented granular control of Auto-DR systems so that building operators could modify or opt out of individualmore » load-shed strategies whenever they wanted. This paper reports the research findings from this effort demonstrated through a field study in large commercial buildings located in New York City. We focused on (1) understanding how providing granular control affects building operators’ perspective on Auto-DR, and (2) evaluating the usefulness of granular control by examining their interaction with the Auto-DR user interface during test events. Through trend log analysis, interviews, and surveys, we found that: (1) the opt-out capability during Auto-DR events can remove the feeling of being forced into load curtailments and increase their willingness to adopt Auto-DR; (2) being able to modify individual load-shed strategies allows flexible Auto-DR participation that meets the building’s changing operational requirements; (3) a clear display of automation strategies helps building operators easily identify how Auto-DR is functioning and can build trust in Auto-DR systems.« less
Oboh, Ganiyu; Akindahunsi, Akintunde A.
2013-01-01
Leachate from a municipal battery recycling site is a potent source of mixed-metal released into the environment. The present study investigated the degree at which mixed-metal exposure to the municipal auto-battery leachate (MABL) and to the Elewi Odo municipal auto-battery recycling site leachate (EOMABRL) affected the lipid membrane of the testes in in vitro experiment. The results showed elevated level of mixed-metals over the permissible levels in drinking water, as recommended by regulatory authorities. In the leachate samples, the levels of malondialdehyde (MDA), a biomarker of lipid damage, was significantly (p<0.05) increased in rat testes in a dose-dependent manner. MDA induced by the municipal auto-battery leachate (MABL) was significantly (p<0.05) higher than the leachate from Elewi Odo municipal auto-battery recycling site (EOMABRL). The testicular lipid membrane capacity was compromised following treatment with leachate from the municipal battery recycling site, implicating mixed-metal exposure as the causative agent of testicular damage and male infertility. PMID:24678257
Akintunde, Jacob K; Oboh, Ganiyu; Akindahunsi, Akintunde A
2013-12-01
Leachate from a municipal battery recycling site is a potent source of mixed-metal released into the environment. The present study investigated the degree at which mixed-metal exposure to the municipal auto-battery leachate (MABL) and to the Elewi Odo municipal auto-battery recycling site leachate (EOMABRL) affected the lipid membrane of the testes in in vitro experiment. The results showed elevated level of mixed-metals over the permissible levels in drinking water, as recommended by regulatory authorities. In the leachate samples, the levels of malondialdehyde (MDA), a biomarker of lipid damage, was significantly (p<0.05) increased in rat testes in a dose-dependent manner. MDA induced by the municipal auto-battery leachate (MABL) was significantly (p<0.05) higher than the leachate from Elewi Odo municipal auto-battery recycling site (EOMABRL). The testicular lipid membrane capacity was compromised following treatment with leachate from the municipal battery recycling site, implicating mixed-metal exposure as the causative agent of testicular damage and male infertility.
Some Thermophysical Properties of Blood Components and Coolants for Frozen Blood Shipping Containers
1989-09-01
SP number by sending a DP reading. Subroutine : AutoControl Automatic control to set temperature. : Autodisplay Get ilL Thermocouple readings and...RETURN 133 AutoControl : Auto control Mode ON TIMER(ReportTime) GOSUB Autodisplay Update Screen in constant interval TIMER ON WHILE Success a 0 Turn off
ArF scanner performance improvement by using track integrated CD optimization
NASA Astrophysics Data System (ADS)
Huang, Jacky; Yu, Shinn-Sheng; Ke, Chih-Ming; Wu, Timothy; Wang, Yu-Hsi; Gau, Tsai-Sheng; Wang, Dennis; Li, Allen; Yang, Wenge; Kaoru, Araki
2006-03-01
In advanced semiconductor processing, shrinking CD is one of the main objectives when moving to the next generation technology. Improving CD uniformity (CDU) with shrinking CD is one of the biggest challenges. From ArF lithography CD error budget analysis, PEB (post exposure bake) contributes more than 40% CD variations. It turns out that hot plate performance such as CD matching and within-plate temperature control play key roles in litho cell wafer per hour (WPH). Traditionally wired or wireless thermal sensor wafers were used to match and optimize hot plates. However, sensor-to-sensor matching and sensor data quality vs. sensor lifetime or sensor thermal history are still unknown. These concerns make sensor wafers more suitable for coarse mean-temperature adjustment. For precise temperature adjustment, especially within-hot-plate temperature uniformity, using CD instead of sensor wafer temperature is a better and more straightforward metrology to calibrate hot plates. In this study, we evaluated TEL clean track integrated optical CD metrology (IM) combined with TEL CD Optimizer (CDO) software to improve 193-nm resist within-wafer and wafer-to-wafer CD uniformity. Within-wafer CD uniformity is mainly affected by the temperature non-uniformity on the PEB hot plate. Based on CD and PEB sensitivity of photo resists, a physical model has been established to control the CD uniformity through fine-tuning PEB temperature settings. CD data collected by track integrated CD metrology was fed into this model, and the adjustment of PEB setting was calculated and executed through track internal APC system. This auto measurement, auto feed forward, auto calibration and auto adjustment system can reduce the engineer key-in error and improve the hot plate calibration cycle time. And this PEB auto calibration system can easily bring hot-plate-to-hot-plate CD matching to within 0.5nm and within-wafer CDU (3σ) to less than 1.5nm.
Auto-phosphorylation Represses Protein Kinase R Activity.
Wang, Die; de Weerd, Nicole A; Willard, Belinda; Polekhina, Galina; Williams, Bryan R G; Sadler, Anthony J
2017-03-10
The central role of protein kinases in controlling disease processes has spurred efforts to develop pharmaceutical regulators of their activity. A rational strategy to achieve this end is to determine intrinsic auto-regulatory processes, then selectively target these different states of kinases to repress their activation. Here we investigate auto-regulation of the innate immune effector protein kinase R, which phosphorylates the eukaryotic initiation factor 2α to inhibit global protein translation. We demonstrate that protein kinase R activity is controlled by auto-inhibition via an intra-molecular interaction. Part of this mechanism of control had previously been reported, but was then controverted. We account for the discrepancy and extend our understanding of the auto-inhibitory mechanism by identifying that auto-inhibition is paradoxically instigated by incipient auto-phosphorylation. Phosphor-residues at the amino-terminus instigate an intra-molecular interaction that enlists both of the N-terminal RNA-binding motifs of the protein with separate surfaces of the C-terminal kinase domain, to co-operatively inhibit kinase activation. These findings identify an innovative mechanism to control kinase activity, providing insight for strategies to better regulate kinase activity.
2003-03-07
File name :DSC_0749.JPG File size :1.1MB(1174690Bytes) Date taken :2003/03/07 13:51:29 Image size :2000 x 1312 Resolution :300 x 300 dpi Number of bits :8bit/channel Protection attribute :Off Hide Attribute :Off Camera ID :N/A Camera :NIKON D1H Quality mode :FINE Metering mode :Matrix Exposure mode :Shutter priority Speed light :No Focal length :20 mm Shutter speed :1/500second Aperture :F11.0 Exposure compensation :0 EV White Balance :Auto Lens :20 mm F 2.8 Flash sync mode :N/A Exposure difference :0.0 EV Flexible program :No Sensitivity :ISO200 Sharpening :Normal Image Type :Color Color Mode :Mode II(Adobe RGB) Hue adjustment :3 Saturation Control :N/A Tone compensation :Normal Latitude(GPS) :N/A Longitude(GPS) :N/A Altitude(GPS) :N/A
Russell, Tanya L.; Braks, Marieta A. H.
2015-01-01
Background Dengue is the most prevalent arboviral disease transmitted by Aedes aegypti worldwide, whose chemical control is difficult, expensive, and of inconsistent efficacy. Releases of Metarhizium anisopliae—exposed Ae. aegypti males to disseminate conidia among female mosquitoes by mating represents a promising biological control approach against this important vector. A better understanding of fungus virulence and impact on reproductive parameters of Ae. aegypti, is need before testing auto-dissemination strategies. Methodology/Principal Findings Mortality, mating competitiveness, sperm production, and the capacity to auto-disseminate the fungus to females up to the 5thcopulation, were compared between Aedes aegypti males exposed to 5.96 x 107 conidia per cm2 of M. anisopliae and uninfected males. Half (50%) of fungus-exposed males (FEMs) died within the first 4 days post-exposure (PE). FEMs required 34% more time to successively copulate with 5 females (165 ± 3 minutes) than uninfected males (109 ± 3 minutes). Additionally, fungus infection reduced the sperm production by 87% at 5 days PE. Some beneficial impacts were observed, FEMs were able to successfully compete with uninfected males in cages, inseminating an equivalent number of females (about 25%). Under semi-field conditions, the ability of FEMs to search for and inseminate females was also equivalent to uninfected males (both inseminating about 40% females); but for the remaining females that were not inseminated, evidence of tarsal contact (transfer of fluorescent dust) was significantly greater in FEMs compared to controls. The estimated conidia load of a female exposed on the 5th copulation was 5,200 mL-1 which was sufficient to cause mortality. Conclusion/Significance Our study is the first to demonstrate auto-dissemination of M. anisopliae through transfer of fungus from males to female Ae. aegypti during mating under semi-field conditions. Our results suggest that auto-dissemination studies using releases of FEMs inside households could successfully infect wild Ae. aegypti females, providing another viable biological control tool for this important the dengue vector. PMID:26473490
Relationship of hemoglobin to occupational exposure to motor vehicle exhaust.
Potula, V; Hu, H
1996-01-01
To study the relationship of hemoglobin to exposure to motor vehicle exhaust. Survey. Traffic police, bus drivers, and auto-shop workers (all exposed to auto exhaust in Madras, India) and unexposed office workers. We measured levels of blood lead (by graphite furnace atomic absorption spectrophotometry), and hemoglobin. Information also was collected on age, employment duration, smoking status, alcohol ingestion, and diet type (vegetarian or nonvegetarian). Increasing exposure to motor vehicle exhaust, as reflected by job category, was significantly associated with lower levels of hemoglobin (p < 0.01). A final multivariate regression model was constructed that began with indicator variables for each job (with office workers as the reference category) and included age, duration of employment, blood lead level, alcohol ingestion, dietary type, and smoking status. After a backward-elimination procedure, employment duration as an auto-shop worker or bus driver remained as significant correlates of lower hemoglobin level and current smoking and long employment duration as significant correlates of higher hemoglobin level. Occupational exposure to automobile exhaust may be a risk factor for decreased hemoglobin level in Madras. This effect appears to be independent of blood lead level and may represent hematopoietic suppression incurred by benzene or accumulated lead burden (which is not well reflected by blood lead levels). Smoking probably increased hemoglobin level through the chronic effects of exposure to carbon monoxide. In this study, a long employment duration may have served as a proxy for better socioeconomic, and therefore, better nutritional status.
Effects of media violence on health-related outcomes among young men.
Brady, Sonya S; Matthews, Karen A
2006-04-01
To test the effects of media violence exposure on blood pressure, negative affect, hostile social information processing, uncooperative behavior, and attitudes toward health risk behaviors among young men varying in lifetime violence exposure within the home and community. Experimental laboratory study. University campus situated within an urban environment. One hundred male undergraduates aged 18 to 21 years. Men who had previously reported differing amounts of lifetime home and community violence were randomly assigned to play The Simpsons: Hit and Run (low-violence condition) or Grand Theft Auto III (high-violence condition). Systolic and diastolic blood pressure; negative affect; hostile social information processing; uncooperative behavior; and permissive attitudes toward violence, alcohol use, marijuana use, and sexual activity without condom use. Men randomly assigned to play Grand Theft Auto III exhibited greater increases in diastolic blood pressure from a baseline rest period to game play, greater negative affect, more permissive attitudes toward using alcohol and marijuana, and more uncooperative behavior in comparison with men randomly assigned to play The Simpsons. Only among participants with greater exposure to home and community violence, play of Grand Theft Auto III led to elevated systolic blood pressure in comparison with play of The Simpsons (mean, 13 vs 5 mm Hg). Media violence exposure may play a role in the development of negative attitudes and behaviors related to health. Although youth growing up in violent homes and communities may become more physiologically aroused by media violence exposure, all youth appear to be at risk for potentially negative outcomes.
Fault tolerant control of multivariable processes using auto-tuning PID controller.
Yu, Ding-Li; Chang, T K; Yu, Ding-Wen
2005-02-01
Fault tolerant control of dynamic processes is investigated in this paper using an auto-tuning PID controller. A fault tolerant control scheme is proposed composing an auto-tuning PID controller based on an adaptive neural network model. The model is trained online using the extended Kalman filter (EKF) algorithm to learn system post-fault dynamics. Based on this model, the PID controller adjusts its parameters to compensate the effects of the faults, so that the control performance is recovered from degradation. The auto-tuning algorithm for the PID controller is derived with the Lyapunov method and therefore, the model predicted tracking error is guaranteed to converge asymptotically. The method is applied to a simulated two-input two-output continuous stirred tank reactor (CSTR) with various faults, which demonstrate the applicability of the developed scheme to industrial processes.
This is an ORD Regional Applied Research Effort (RARE) study with EPA Region 1. For the past several years Region 1 has been managing an EPA grant for an auto body shop compliance assistance project in Lawrence, MA to address residents' concerns about auto body shops as a source...
Demir, E; Yeğit, O; Erol, A; Akgül, S U; Çalışkan, B; Bayraktar, A; Çalışkan, Y; Türkmen, A; Savran, F O; Sever, M S
2017-04-01
The crossmatch test is essential prior to kidney transplantation (tx) to confirm compatibility between the donor and the recipient. However, its results can be misleading due to "undetectable antibodies" in the recipient's serum. To establish if undetectable autoantibodies are responsible for a positive result, an auto-crossmatch test can be performed. In this study, we aim to determine the long-term prognostic value of auto-flow cytometric auto-crossmatch (FCXM) test on kidney survival in kidney tx recipients. The primary outcome variable was reduced renal function. Secondary endpoints were incidence of biopsy-confirmed chronic antibody-mediated rejection (CAMR) and recurrent glomerulonephritis (GN). There were no differences regarding initial serum creatinine levels between the study and control groups (P = .441). Patients who had positive auto-B FCXM had a significantly reduced renal function compared with the control group (P = .016). Four patients developed biopsy-confirmed CAMR in the study group and 1 patient in the control group (P = .047). Five patients had biopsy-confirmed recurrent GN in the GN study group, and only 1 patient had recurrent GN in the GN control group (P = .026). Kidney transplant recipients with positive auto-FCXM test had significantly reduced renal function and a higher incidence of recurrent GN and CAMR compared with the control group. The findings of this study suggest a potential role of auto-antibody causing positive auto-FCXM test result, meanwhile increasing the risk of CAMR, recurrent GN, and new-onset diabetes after tx. Copyright © 2017 Elsevier Inc. All rights reserved.
Malignant Mesothelioma in a Motor Vehicle Mechanic.
Meisenkothen, Christopher
2017-02-01
Case reports remain an important source of data in the debate over the carcinogenic effect of asbestos-containing automotive friction products. This report documents a case of pleural mesothelioma accompanied by asbestos bodies in the lung tissue of a career auto mechanic with no other known sources of exposure. Previously unreported historical and contemporary exposure data are also discussed in the context of providing additional support for the proposition that work with asbestos-containing automotive products presents a risk of significant exposure. While there remains a body of negative epidemiology that fails to find an increased risk of disease among auto workers, those data must be approached with caution. Many of those studies have drawn technical criticisms, which are beyond the scope of this report, but they remain a key part of the legal defense mounted by defendant-companies who are involved in asbestos-related litigation. This ongoing debate provides the context for the continued relevance of case reports such as this one, as well as the presentation of new and previously unpublished exposure data.
Wang, Kevin K W; Yang, Zhihui; Yue, John K; Zhang, Zhiqun; Winkler, Ethan A; Puccio, Ava M; Diaz-Arrastia, Ramon; Lingsma, Hester F; Yuh, Esther L; Mukherjee, Pratik; Valadka, Alex B; Gordon, Wayne A; Okonkwo, David O; Manley, Geoffrey T; Cooper, Shelly R; Dams-O'Connor, Kristen; Hricik, Allison J; Inoue, Tomoo; Maas, Andrew I R; Menon, David K; Schnyer, David M; Sinha, Tuhin K; Vassar, Mary J
2016-07-01
We described recently a subacute serum autoantibody response toward glial fibrillary acidic protein (GFAP) and its breakdown products 5-10 days after severe traumatic brain injury (TBI). Here, we expanded our anti-GFAP autoantibody (AutoAb[GFAP]) investigation to the multicenter observational study Transforming Research and Clinical Knowledge in TBI Pilot (TRACK-TBI Pilot) to cover the full spectrum of TBI (Glasgow Coma Scale 3-15) by using acute (<24 h) plasma samples from 196 patients with acute TBI admitted to three Level I trauma centers, and a second cohort of 21 participants with chronic TBI admitted to inpatient TBI rehabilitation. We find that acute patients self-reporting previous TBI with loss of consciousness (LOC) (n = 43) had higher day 1 AutoAb[GFAP] (mean ± standard error: 9.11 ± 1.42; n = 43) than healthy controls (2.90 ± 0.92; n = 16; p = 0.032) and acute patients reporting no previous TBI (2.97 ± 0.37; n = 106; p < 0.001), but not acute patients reporting previous TBI without LOC (8.01 ± 1.80; n = 47; p = 0.906). These data suggest that while exposure to TBI may trigger the AutoAb[GFAP] response, circulating antibodies are elevated specifically in acute TBI patients with a history of TBI. AutoAb[GFAP] levels for participants with chronic TBI (average post-TBI time 176 days or 6.21 months) were also significantly higher (15.08 ± 2.82; n = 21) than healthy controls (p < 0.001). These data suggest a persistent upregulation of the autoimmune response to specific brain antigen(s) in the subacute to chronic phase after TBI, as well as after repeated TBI insults. Hence, AutoAb[GFAP] may be a sensitive assay to study the dynamic interactions between post-injury brain and patient-specific autoimmune responses across acute and chronic settings after TBI.
Diisocyanate-exposed auto body shop workers: a one-year follow-up.
Redlich, C A; Stowe, M H; Coren, B A; Wisnewski, A V; Holm, C T; Cullen, M R
2002-12-01
Diisocyanates currently are the most commonly identified cause of occupational asthma in industrialized countries. Auto body shops, a common hexamethylene diisocyanate (HDI) exposure setting, are difficult to study due to their small size and episodic exposures. A 1-year follow-up was undertaken as an adjunct to the cross-sectional SPRAY study (Survey of Painters & Repairers of Auto bodies by Yale) to investigate the effects of HDI on auto body shop workers over time and whether or not the healthy worker effect may exist in this industry. Forty-eight workers from seven shops were re-contacted. Thirty-four subjects who stayed at the same shop and 11 who left their original shop participated. No statistically significant changes in physiology, symptoms, and immunologic responses from baseline to follow-up were noted. However, significant differences between those who left the shops and those who stayed were noted. Those who left were younger, less experienced in the industry, and more likely to have a history of asthma (23 vs. 3%; P < 0.05), bronchial hyper-responsiveness (23 vs. 9%), HDI-specific IgG (64 vs. 29%; P < 0.05), and HDI-specific proliferation (S.I. 2.0 vs. 1.3; P < 0.05). The differences in workers who stayed at their shop compared to those who left, combined with the low asthma prevalence and high job turnover rate, all suggest that a healthy worker effect may exist in the auto body industry, and may in part account for the low prevalence of asthma noted in SPRAY and other cross-sectional studies of diisocyante workers. Copyright 2002 Wiley-Liss, Inc.
Mawatari, M; Higo, T; Tsutsumi, Y; Shigematsu, M; Hotokebuchi, T
2006-08-01
To evaluate the effectiveness of autologous fibrin tissue adhesive (auto-FTA) in reducing blood loss during cementless total hip arthroplasty (THA). From September 2000 to August 2001, 100 patients who predonated 400 ml of autologous blood were randomised to undergo either standard treatment with auto-FTA (auto-FTA group) or standard treatment alone (control group). The volume of postoperative blood loss and the decrease in haemoglobin level were measured. All patients were followed up for 3 years to evaluate the rate of bone ingrowth and heterotopic ossification. The mean postoperative blood loss was 580 ml (standard deviation [SD], 240 ml) in the auto-FTA group and 810 ml (SD, 341 ml) in the control group; the difference was significant (230 ml, p<0.001). The decrease in haemoglobin concentration was 17 g/l (SD, 11 g/l) in the auto-FTA group and 22 g/l (SD, 12 g/l) in the control group. The difference was significant (5 g/l, p=0.03). The percentage of total blood loss of >1200 ml in any single patient was significantly lower in the auto-FTA group (4%) than in the control group (20%) [p=0.01]. Auto-FTA is a safe and effective means of reducing perioperative blood loss in THA.
Akintunde, Adeseye A; Oloyede, Taiwo W
2017-11-01
To determine occupational association with metabolic syndrome among auto technicians and school teachers. One hundred and sixty six subjects were selected for this study. Clinical data was obtained while laboratory investigations including plasma glucose and lipid profile were performed. Statistical analysis was done with SPSS 20.0. P<0.05 was taken as statistically significant. School teachers had significantly higher mean total cholesterol and LDL-cholesterol compared to auto technicians. Mean serum triglycerides was significantly higher among auto-technicians compared to school teachers in this study. The prevalence of some conventional cardiovascular risk factors was significantly higher among auto-technicians compared to school teachers: Impaired blood glucose (9.6% vs. 1.2%, p<0.05), hypertriglyceridaemia (18.1% vs. 7.2%, p<0.05) and low HDL-Cholesterol (47.0% vs. 37.3%, p<0.05) respectively. However elevated LDL-cholesterol (56.6% vs. 32.5%, p<0.05) was significantly more common among school teachers compared to auto-technicians. Based on the WHO and the Harmonized criteria, metabolic syndrome was more frequent among auto-technicians compared to school teachers. (8.4% vs. 1.2% and 19.3% vs. 7.2% respectively, p<0.05) CONCLUSION: The prevalence of metabolic syndrome appears to be significantly higher among auto technicians despite their high level of physical activity, exertion and education compared to teachers. This may be related to the increased occupational exposure to organic and inorganic materials from dust particles, oil and oil related matter and particulate matter among auto technicians. Prompt definitive evaluation of this concept and appropriate health education to encourage safety mechanism can reduce this burden of metabolic syndrome among auto technicians in Nigeria. Copyright © 2016 Diabetes India. Published by Elsevier Ltd. All rights reserved.
Autonomous GN and C for Spacecraft Exploration of Comets and Asteroids
NASA Technical Reports Server (NTRS)
Carson, John M.; Mastrodemos, Nickolaos; Myers, David M.; Acikmese, Behcet; Blackmore, James C.; Moussalis, Dhemetrio; Riedel, Joseph E.; Nolet, Simon; Chang, Johnny T.; Mandic, Milan;
2010-01-01
A spacecraft guidance, navigation, and control (GN&C) system is needed to enable a spacecraft to descend to a surface, take a sample using a touch-and-go (TAG) sampling approach, and then safely ascend. At the time of this reporting, a flyable GN&C system that can accomplish these goals is beyond state of the art. This article describes AutoGNC, which is a GN&C system capable of addressing these goals, which has recently been developed and demonstrated to a maturity TRL-5-plus. The AutoGNC solution matures and integrates two previously existing JPL capabilities into a single unified GN&C system. The two capabilities are AutoNAV and GREX. AutoNAV is JPL s current flight navigation system, and is fairly mature with respect to flybys and rendezvous with small bodies, but is lacking capability for close surface proximity operations, sampling, and contact. G-REX is a suite of low-TRL algorithms and capabilities that enables spacecraft operations in close surface proximity and for performing sampling/contact. The development and integration of AutoNAV and G-REX components into AutoGNC provides a single, unified GN&C capability for addressing the autonomy, close-proximity, and sampling/contact aspects of small-body sample return missions. AutoGNC is an integrated capability comprising elements that were developed separately. The main algorithms and component capabilities that have been matured and integrated are autonomy for near-surface operations, terrain-relative navigation (TRN), real-time image-based feedback guidance and control, and six degrees of freedom (6DOF) control of the TAG sampling event. Autonomy is achieved based on an AutoGNC Executive written in Virtual Machine Language (VML) incorporating high-level control, data management, and fault protection. In descending to the surface, the AutoGNC system uses camera images to determine its position and velocity relative to the terrain. This capability for TRN leverages native capabilities of the original AutoNAV system, but required advancements that integrate the separate capabilities for shape modeling, state estimation, image rendering, defining a database of onboard maps, and performing real-time landmark recognition against the stored maps. The ability to use images to guide the spacecraft requires the capability for image-based feedback control. In Auto- GNC, navigation estimates are fed into an onboard guidance and control system that keeps the spacecraft guided along a desired path, as it descends towards its targeted landing or sampling site. Once near the site, AutoGNC achieves a prescribed guidance condition for TAG sampling (position/orientation, velocity), and a prescribed force profile on the sampling end-effector. A dedicated 6DOF TAG control then implements the ascent burn while recovering from sampling disturbances and induced attitude rates. The control also minimizes structural interactions with flexible solar panels and disallows any part of the spacecraft from making contact with the ground (other than the intended end-effector).
Practical Tests with the "auto Control Slot." Part II : Discussion
NASA Technical Reports Server (NTRS)
Lachmann, G
1930-01-01
For some time the D.V.L. has been investigating the question of applicability of Handley Page slotted wings to German airplanes. Comparitive gliding tests were made with open and closed slots on an Albatros L 75 airplane equipped with the Handley Page "auto control slots." This investigation served to determine the effect of the auto control slot on the properties and performances of airplanes at large angles of attack. The most important problems were whether the angle of glide at small angles of attack can be increased by the adoption of the auto control slot and, in particular, as to whether the flight characteristics at large angles of attack are improved thereby and equilibrium in gliding flight is guaranteed even at larger than ordinary angles of attack.
Practical Tests with the "auto Control Slot." Part I : Lecture
NASA Technical Reports Server (NTRS)
Lachmann, G
1930-01-01
For some time the D.V.L. has been investigating the question of applicability of Handley Page slotted wings to German airplanes. Comparitive gliding tests were made with open and closed slots on an Albatros L 75 airplane equipped with the Handley Page "auto control slots." This investigation served to determine the effect of the auto control slot on the properties and performances of airplanes at large angles of attack. The most important problems were whether the angle of glide at small angles of attack can be increased by the adoption of the auto control slot and, in particular, as to whether the flight characteristics at large angles of attack are improved thereby and equilibrium in gliding flight is guaranteed even at larger than ordinary angles of attack.
AutoLock: a semiautomated system for radiotherapy treatment plan quality control
Lowe, Matthew; Hardy, Mark J.; Boylan, Christopher J.; Whitehurst, Philip; Rowbottom, Carl G.
2015-01-01
A semiautomated system for radiotherapy treatment plan quality control (QC), named AutoLock, is presented. AutoLock is designed to augment treatment plan QC by automatically checking aspects of treatment plans that are well suited to computational evaluation, whilst summarizing more subjective aspects in the form of a checklist. The treatment plan must pass all automated checks and all checklist items must be acknowledged by the planner as correct before the plan is finalized. Thus AutoLock uniquely integrates automated treatment plan QC, an electronic checklist, and plan finalization. In addition to reducing the potential for the propagation of errors, the integration of AutoLock into the plan finalization workflow has improved efficiency at our center. Detailed audit data are presented, demonstrating that the treatment plan QC rejection rate fell by around a third following the clinical introduction of AutoLock. PACS number: 87.55.Qr PMID:26103498
AutoLock: a semiautomated system for radiotherapy treatment plan quality control.
Dewhurst, Joseph M; Lowe, Matthew; Hardy, Mark J; Boylan, Christopher J; Whitehurst, Philip; Rowbottom, Carl G
2015-05-08
A semiautomated system for radiotherapy treatment plan quality control (QC), named AutoLock, is presented. AutoLock is designed to augment treatment plan QC by automatically checking aspects of treatment plans that are well suited to computational evaluation, whilst summarizing more subjective aspects in the form of a checklist. The treatment plan must pass all automated checks and all checklist items must be acknowledged by the planner as correct before the plan is finalized. Thus AutoLock uniquely integrates automated treatment plan QC, an electronic checklist, and plan finalization. In addition to reducing the potential for the propagation of errors, the integration of AutoLock into the plan finalization workflow has improved efficiency at our center. Detailed audit data are presented, demonstrating that the treatment plan QC rejection rate fell by around a third following the clinical introduction of AutoLock.
Liu, Youcheng; Stowe, Meredith H; Bello, Dhimiter; Sparer, Judy; Gore, Rebecca J; Cullen, Mark R; Redlich, Carrie A; Woskie, Susan R
2009-01-01
Isocyanate skin exposure may play an important role in sensitization and the development of isocyanate asthma, but such exposures are frequently intermittent and difficult to assess. Exposure metrics are needed to better estimate isocyanate skin exposures. The goal of this study was to develop a semiquantitative algorithm to estimate personal skin exposures in auto body shop workers using task-based skin exposure data and daily work diaries. The relationship between skin and respiratory exposure metrics was also evaluated. The development and results of respiratory exposure metrics were previously reported. Using the task-based data obtained with a colorimetric skin exposure indicator and a daily work diary, we developed a skin exposure algorithm to estimate a skin exposure index (SEI) for each worker. This algorithm considered the type of personal protective equipment (PPE) used, the percentage of skin area covered by PPE and skin exposures without and underneath the PPE. The SEI was summed across the day (daily SEI) and survey week (weekly average SEI) for each worker, compared among the job title categories and also compared with the respiratory exposure metrics. A total of 893 person-days was calculated for 232 workers (49 painters, 118 technicians and 65 office workers) from 33 auto body shops. The median (10th-90th percentile, maximum) daily SEI was 0 (0-0, 1.0), 0 (0-1.9, 4.8) and 1.6 (0-3.5, 6.1) and weekly average SEI was 0 (0-0.0, 0.7), 0.3 (0-1.6, 4.2) and 1.9 (0.4-3.0, 3.6) for office workers, technicians and painters, respectively, which were significantly different (P < 0.0001). The median (10th-90th percentile, maximum) daily SEI was 0 (0-2.4, 6.1) and weekly average SEI was 0.2 (0-2.3, 4.2) for all workers. A relatively weak positive Spearman correlation was found between daily SEI and time-weighted average (TWA) respiratory exposure metrics (microg NCO m(-3)) (r = 0.380, n = 893, P < 0.0001) and between weekly SEI and TWA respiratory exposure metrics (r = 0.482, n = 232, P < 0.0001). The skin exposure algorithm developed in this study provides task-based personal daily and weekly average skin exposure indices that are adjusted for the use of PPE. These skin exposure indices can be used to assess isocyanate exposure-response relationships.
Frew, A J
2011-01-01
Anaphylaxis is a systemic allergic reaction that often involves respiratory symptoms and cardiovascular collapse, which are potentially life-threatening if not treated promptly with intramuscular adrenaline. Owing to the unpredictable nature of anaphylaxis and accidental exposure to allergens (such as peanuts and shellfish), patients should be prescribed intramuscular adrenaline auto-injectors and carry these with them at all times. Patients also need to be able to use their auto-injectors correctly while under high stress, when an anaphylactic attack occurs. Despite this, an alarming number of patients fail to carry their auto-injectors and many patients, carers of children with known anaphylaxis and healthcare professionals do not know how to use the device correctly, despite having had training. Currently available auto-injector devices have various limitations that may impede their use in the management of anaphylaxis. There is also a lack of validated assessment criteria and regulatory requirements for new devices. This review describes the different delivery systems used in currently available auto-injectors and discusses the key barriers to the use of adrenaline auto-injectors, with the goal of identifying the 'ideal' features/characteristics of such devices in the emergency treatment of anaphylaxis that will ensure ease of use, portability and accurate delivery of a life-saving drug. © 2010 John Wiley & Sons A/S.
Kumar, Pramod; Gupta, N C
2016-01-15
A public health concern is to understand the linkages between specific pollution sources and adverse health impacts. Commuting can be viewed as one of the significant-exposure activity in high-vehicle density areas. This paper investigates the commuter exposure to inhalable, thoracic and alveolic particles in various transportation modes in Delhi, India. Air pollution levels are significantly contributed by automobile exhaust and also in-vehicle exposure can be higher sometime than ambient levels. Motorcycle, auto rickshaw, car and bus were selected to study particles concentration along two routes in Delhi between Kashmere Gate and Dwarka. The bus and auto rickshaw were running on compressed natural gas (CNG) while the car and motorcycle were operated on gasoline fuel. Aerosol spectrometer was employed to measure inhalable, thoracic and alveolic particles during morning and evening rush hours for five weekdays. From the study, we observed that the concentration levels of these particles were greatly influenced by transportation modes. Concentrations of inhalable particles were found higher during morning in auto rickshaw (332.81 ± 90.97 μg/m(3)) while the commuter of bus exhibited higher exposure of thoracic particles (292.23 ± 110.45 μg/m(3)) and car commuters were exposed to maximum concentrations of alveolic particles (222.37 ± 26.56 μg/m(3)). We observed that in evening car commuters experienced maximum concentrations of all sizes of particles among the four commuting modes. Interestingly, motorcycle commuters were exposed to lower levels of inhalable and thoracic particles during morning and evening hours as compared to other modes of transport. The mean values were found greater than the median values for all the modes of transport suggesting that positive skewed distributions are characteristics of naturally occurring phenomenon. Copyright © 2015 Elsevier B.V. All rights reserved.
: 0; } .dl-horizontal dt { float: none; width: auto; clear: none; text-align: left; } .dl-horizontal dd { margin-left: 0; } .container { width: auto; } .row-fluid { width: 100%; } .row, .thumbnails [class*="span"] { display: inline-block; width: auto; } .controls-row [class*="span"
Teng, Scott Kie Zin; Chong, Gabriel Yew Mun; Siew, Amy Sok Cheng; Skoric, Marko M
2011-10-01
Given the increasingly dominant role of video games in the mainstream entertainment industry, it is no surprise that the scholarly debate about their impact has been lively and well attended. Although >100 studies have been conducted to examine the impact of violent video games on aggression, no clear consensus has been reached, particularly in terms of their long-term impact on violent behavior and aggressive cognitions. This study employs a first-ever longitudinal laboratory-based experiment to examine longer-term effects of playing a violent video game. One hundred thirty-five participants were assigned either to the treatment condition where they played a violent video game in a controlled laboratory setting for a total of 12 hours or to the control group where they did not play a game. Participants in the treatment group played Grand Theft Auto IV over a period of 3 weeks and were compared with a control group on the posttest measures of trait aggression, attitudes toward violence, and empathy. The findings do not support the assertion that playing a violent video game for a period of 3 weeks increases aggression or reduces empathy, but they suggest a small increase in proviolence attitudes. The implications of the findings are discussed.
Systemic and anti-neuronal auto-antibodies in patients with paraneoplastic neurological disease.
Moll, J W; Hooijkaas, H; van Goorbergh, B C; Roos, L G; Henzen-Logmans, S C; Vecht, C J
1996-01-01
Sera from 23 patients with paraneoplastic disease of the central nervous system (PNS) were examined for the presence of anti-neuronal (anti-Hu, anti-Yo/PCA) and anti-Ri) and systemic auto-antibodies, including antibodies against DNA, centromeres, nRNP, Sm antigen, Scl-70, Ro(SS-A), La(SS-B), mitochondria, thyroid antigens, parietal calls, brush border antigen and rheumatoid factor. As controls, sera from 33 patients with small cell lung cancer, 33 with ovarian cancer and 7 with breast cancer and from 107 aged-matched healthy persons were used. Systemic auto-antibodies were found in 52% of patients with paraneoplastic neurological syndromes compared with only 16% (P = 0.001) in the control group with cancer only and 15% in the group of healthy controls. The relatively high percentage of systemic auto-antibodies in patients with PNS indicates that there is a genetic susceptibility to the development of auto-immune phenomena. This may provide an explanation for the relatively rare occurrence of PNS in patients with cancer.
Feedback circuit design of an auto-gating power supply for low-light-level image intensifier
NASA Astrophysics Data System (ADS)
Yang, Ye; Yan, Bo; Zhi, Qiang; Ni, Xiao-bing; Li, Jun-guo; Wang, Yu; Yao, Ze
2015-11-01
This paper introduces the basic principle of auto-gating power supply which using a hybrid automatic brightness control scheme. By the analysis of current as image intensifier to special requirements of auto-gating power supply, a feedback circuit of the auto-gating power supply is analyzed. Find out the reason of the screen flash after the auto-gating power supply assembled image intensifier. This paper designed a feedback circuit which can shorten the response time of auto-gating power supply and improve screen slight flicker phenomenon which the human eye can distinguish under the high intensity of illumination.
Design of an iterative auto-tuning algorithm for a fuzzy PID controller
NASA Astrophysics Data System (ADS)
Saeed, Bakhtiar I.; Mehrdadi, B.
2012-05-01
Since the first application of fuzzy logic in the field of control engineering, it has been extensively employed in controlling a wide range of applications. The human knowledge on controlling complex and non-linear processes can be incorporated into a controller in the form of linguistic terms. However, with the lack of analytical design study it is becoming more difficult to auto-tune controller parameters. Fuzzy logic controller has several parameters that can be adjusted, such as: membership functions, rule-base and scaling gains. Furthermore, it is not always easy to find the relation between the type of membership functions or rule-base and the controller performance. This study proposes a new systematic auto-tuning algorithm to fine tune fuzzy logic controller gains. A fuzzy PID controller is proposed and applied to several second order systems. The relationship between the closed-loop response and the controller parameters is analysed to devise an auto-tuning method. The results show that the proposed method is highly effective and produces zero overshoot with enhanced transient response. In addition, the robustness of the controller is investigated in the case of parameter changes and the results show a satisfactory performance.
Sheikh, Aziz; Simons, F Estelle R; Barbour, Victoria; Worth, Allison
2012-08-15
Anaphylaxis is a serious hypersensitivity reaction that is rapid in onset and may cause death. Adrenaline (epinephrine) auto-injectors are recommended as the initial, potentially life-saving treatment of choice for anaphylaxis in the community, but they are not universally available and have limitations in their use. To assess the effectiveness of adrenaline (epinephrine) auto-injectors in relieving respiratory, cardiovascular, and other symptoms during episodes of anaphylaxis that occur in the community. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2012, Issue 1), MEDLINE (Ovid SP) (1950 to January 2012), EMBASE (Ovid SP) (1980 to January 2012 ), CINAHL (EBSCO host) (1982 to January 2012 ), AMED (EBSCO host) (1985 to January 2012 ), LILACS, (BIREME) (1980 to January 2012 ), ISI Web of Science (1950 to January 2012 ). We adapted our search terms for other databases. We also searched websites listing on-going trials: the World Health Organization International Clinical Trials Registry Platform, the UK Clinical Research Network Study Portfolio, and the meta Register of Controlled Trials; and contacted pharmaceutical companies who manufacture adrenaline auto-injectors in an attempt to locate unpublished material. Randomized and quasi-randomized controlled trials comparing auto-injector administration of adrenaline with any control including no intervention, placebo, or other adrenergic agonists were eligible for inclusion. Two authors independently assessed articles for inclusion. None of the 1328 studies that were identified satisfied the inclusion criteria. Based on this review, we cannot make any new recommendations on the effectiveness of adrenaline auto-injectors for the treatment of anaphylaxis. Although randomized, double-blind, placebo-controlled clinical trials of high methodological quality are necessary to define the true extent of benefits from the administration of adrenaline in anaphylaxis via an auto-injector, such trials are unlikely to be performed in individuals experiencing anaphylaxis because of ethical concerns associated with randomization to placebo. There is, however, a need to consider trials in which, for example, auto-injectors of different doses of adrenaline and differing devices are compared in order to provide greater clarity on the dose and device of choice. Such trials would be practically challenging to conduct. In the absence of appropriate trials, we recommend that adrenaline administration by auto-injector should still be regarded as the most effective first-line treatment for the management of anaphylaxis in the community. In countries where auto-injectors are not commonly used, it may be possible to conduct trials to compare administration of adrenaline via auto-injector with adrenaline administered by syringe and ampoule, or comparing the effectiveness of two different types of auto-injector.
14 CFR 61.67 - Category II pilot authorization requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... and runway lighting system; (ix) Characteristics and limitations of the flight director system, auto approach coupler (including split axis type if equipped), auto throttle system (if equipped), and other... be made with the use of an approved flight control guidance system, except if an approved auto...
An Instructional Method for the AutoCAD Modeling Environment.
ERIC Educational Resources Information Center
Mohler, James L.
1997-01-01
Presents a command organizer for AutoCAD to aid new uses in operating within the 3-D modeling environment. Addresses analyzing the problem, visualization skills, nonlinear tools, a static view of a dynamic model, the AutoCAD organizer, environment attributes, and control of the environment. Contains 11 references. (JRH)
[Evaluation of exposure of auto painters to organic solvents in the city of Bogota].
Palma, Marien; Briceño, Leonardo; Idrovo, Álvaro J; Varona, Marcela
2015-08-01
Painters of automobiles are exposed to pure and mixed solvents that have been associated with neurological effects and carcinogenic mutations. To characterize the health and work conditions of individuals who are occupationally exposed to organic solvents used in sheet metal and auto body shops in Bogota. Descriptive, cross-sectional study that characterizes the health and work conditions of individuals exposed to organic solvents in sheet metal and auto body shops in Bogota. A group exposed to the solvents was compared to an unexposed group. Air concentrations of benzene, toluene and xylene (BTX) were determined, individual questionnaires were administered and phenylmercapturic, hippuric and ortho- and para-methylhippuric acids were measured in urine. The results of the measurements and the questionnaires were correlated to determine the exposure panorama. For the three BTX metabolites, statistically significant differences (p<0.001) were found between the population exposed to the solvents and the unexposed population. For the exposed population, positive correlations were found between toluene in air and hippuric acid in urine (rho=0.82) and between xylene in air and o-methylhippuric acid in urine (rho=0.76). Hippuric acid values exceeded permissible levels in 11 workers and p-methylhippuric acid exceeded permissible levels in 8 workers. None of the phenylmercapturic values exceeded the limit. Auto painters are exposed to high levels of organic solvents at the workplace and do not have adequate industrial health and safety conditions to perform their jobs.
Xiao, Songshu; Wan, Yajun; Zou, Fangjun; Ye, Mingzhu; Deng, Henan; Ma, Jiezhi; Wei, Yingying; Tan, Chen; Xue, Min
2015-01-01
To evaluate the efficacy and safety of auto-crosslinked hyaluronic acid (HA) gel for preventing intrauterine adhesion (IUA) after hysteroscopic adhesiolysis. A prospective, randomized, double blinded and controlled clinical trial (level I) was performed. According to American Fertility Society (AFS) scoring system, 120 patients (treatment group: 60 cases, control group: 60 cases) with moderate to severe IUA were enrolled. Upon completion of adhesiolysis, a Foley balloon catheter was first introduced into the uterine cavity and then 3 ml of auto-crosslinked HA gel for patients in the treatment group; patients in the control group, however, only received Foley balloon catheter. Second-look hysteroscopic examination was performed to all patients at 3 months postoperatively for evaluation of IUA. Primary endpoint was the reduction rate of IUA at 3 months after surgery. The secondary endpoints include total AFS score, score of each individual AFS category. At 3 months after surgery, auto-crosslinked HA gel resulted in significantly higher effective rate for reduction of adhesion, the effective rate were 76% (42/55) and 48% (27/56) respectively (P = 0.000 9); the total AFS score of treatment group was 2.1 ± 1.1, and significantly lower than that of control group (3.7 ± 2.5, P = 0.000 8). Application of auto-crosslinked HA gel after surgery significantly enhanced the improvement for each individual patient with regard to their adhesive type and menstrual pattern (P = 0.037 8, P = 0.000 4). The treatment group had significantly lower proportion of patients with moderate to severe adhesive stages than that of control group [13% (7/55) versus 38% (21/56), P = 0.000 6]. No adverse events and complications were observed. Auto-crosslinked HA gel coule be able to reduce IUA, decrease adhesion severity, and improve menopause postoperatively. This absorbable auto-crosslinked HA gel is proposed as a barrier for preventing IUA after intrauterine procedures.
Hand dermatitis in auto mechanics and machinists.
Donovan, Jeffrey C H; Kudla, Irena; Holness, D Linn
2007-09-01
Auto mechanics and machinists presenting with suspected allergic contact dermatitis (ACD) have traditionally been patch-tested with a standard screening tray and a specialty tray such as the Oil and Cooling Fluid Series. While this has proven useful for patch-testing the machinist, there is a need for the development of a more specific allergen testing tray for the auto mechanic. The objective of the study was to compare clinical features and patch-test results of auto mechanics and machinists with hand dermatitis to evaluate differences in allergen profiles. We performed a chart review of 33 auto mechanics and 24 machinists referred to our Occupational Contact Dermatitis Clinic from 2002 to 2005 for evaluation of hand dermatitis. With a panel of 84 allergens, 52 positive reactions were detected in 17 cases of ACD in mechanics. The profiles were different from the cases of ACD diagnosed in 10 of 24 machinists. Mechanics and machinists differ in the spectrum of occupational exposures. Patch testing with greater numbers of allergens likely identifies a larger proportion of mechanics with occupationally relevant ACD. Further study is needed to determine the most appropriate allergens to include in a clinically useful "mechanic's tray."
Agalliu, Ilir; Kriebel, David; Quinn, Margaret M; Wegman, David H; Eisen, Ellen A
2005-09-01
Exposure to metalworking fluids has been previously associated with prostate cancer mortality in a cohort of autoworkers. Our objective was to further explore this finding in a study of prostate cancer incidence in the same cohort, with reduced misclassification of outcome. We conducted a nested case-control study in the General Motors cohort of autoworkers. Incident cases of prostate cancer (n = 872) were identified via the Michigan Cancer Registry from 1985 through 2000. Controls were selected using incidence-density sampling with 5:1 ratio. Using cumulative exposure (mg/m-years) as the dose metric, we first examined varying lengths of lags (0-25 years). Then, we evaluated consecutive windows of exposure: 25 or more years before risk age, and fewer than 25 years. We used penalized splines to model the relative risk as a smooth function of exposure, and adjusted for race and calendar year of diagnosis in a Cox model. Risk of prostate cancer increased with exposure to soluble and straight fluids 25 years or more before risk age but not with exposure in the last 25 years. The relationship with soluble fluids was piecewise linear, with a small increase in risk at lower exposures followed by a steeper rise. By contrast, the relationship with straight fluids was linear, with a relative risk of 1.12 per 10mg/m-years of exposure (95% confidence interval = 1.04-1.20). Exposure to oil-based fluids, soluble and straight, is modestly associated with prostate cancer risk among autoworkers, with a latency period of at least 25 years.
78 FR 54751 - Airworthiness Directives; Bell Helicopter Textron Canada Inc. Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-06
... certain part-numbered engine auto-relight kit control boxes. This AD was prompted by a design review that revealed the control box chipset did not meet the required temperature range requirements, which could cause the control box to malfunction, disabling the engine auto-relight system. The actions of this AD...
Assessment of Factors Related to Auto-PEEP.
Natalini, Giuseppe; Tuzzo, Daniele; Rosano, Antonio; Testa, Marco; Grazioli, Michele; Pennestrì, Vincenzo; Amodeo, Guido; Marsilia, Paolo F; Tinnirello, Andrea; Berruto, Francesco; Fiorillo, Marialinda; Filippini, Matteo; Peratoner, Alberto; Minelli, Cosetta; Bernardini, Achille
2016-02-01
Previous physiological studies have identified factors that are involved in auto-PEEP generation. In our study, we examined how much auto-PEEP is generated from factors that are involved in its development. One hundred eighty-six subjects undergoing controlled mechanical ventilation with persistent expiratory flow at the beginning of each inspiration were enrolled in the study. Volume-controlled continuous mandatory ventilation with PEEP of 0 cm H2O was applied while maintaining the ventilator setting as chosen by the attending physician. End-expiratory and end-inspiratory airway occlusion maneuvers were performed to calculate respiratory mechanics, and tidal flow limitation was assessed by a maneuver of manual compression of the abdomen. The variable with the strongest effect on auto-PEEP was flow limitation, which was associated with an increase of 2.4 cm H2O in auto-PEEP values. Moreover, auto-PEEP values were directly related to resistance of the respiratory system and body mass index and inversely related to expiratory time/time constant. Variables that were associated with the breathing pattern (tidal volume, frequency minute ventilation, and expiratory time) did not show any relationship with auto-PEEP values. The risk of auto-PEEP ≥5 cm H2O was increased by flow limitation (adjusted odds ratio 17; 95% CI: 6-56.2), expiratory time/time constant ratio <1.85 (12.6; 4.7-39.6), respiratory system resistance >15 cm H2O/L s (3; 1.3-6.9), age >65 y (2.8; 1.2-6.5), and body mass index >26 kg/m(2) (2.6; 1.1-6.1). Flow limitation, expiratory time/time constant, resistance of the respiratory system, and obesity are the most important variables that affect auto-PEEP values. Frequency expiratory time, tidal volume, and minute ventilation were not independently associated with auto-PEEP. Therapeutic strategies aimed at reducing auto-PEEP and its adverse effects should be primarily oriented to the variables that mainly affect auto-PEEP values. Copyright © 2016 by Daedalus Enterprises.
Akhtar, Rizwan S; Licata, Joseph P; Luk, Kelvin C; Shaw, Leslie M; Trojanowski, John Q; Lee, Virginia M-Y
2018-03-03
Biomarkers for α-synuclein are needed for diagnosis and prognosis in Parkinson's disease (PD). Endogenous auto-antibodies to α-synuclein could serve as biomarkers for underlying synucleinopathy, but previous assessments of auto-antibodies have shown variability and inconsistent clinical correlations. We hypothesized that auto-antibodies to α-synuclein could be diagnostic for PD and explain its clinical heterogeneity. To test this hypothesis, we developed an enzyme-linked immunosorbent assay for measuring α-synuclein auto-antibodies in human samples. We evaluated 69 serum samples (16 healthy controls (HC) and 53 PD patients) and 145 CSF samples (52 HC and 93 PD patients) from our Institution. Both serum and CSF were available for 24 participants. Males had higher auto-antibody levels than females in both fluids. CSF auto-antibody levels were significantly higher in PD patients as compared to HC, whereas serum levels were not significantly different. CSF auto-antibody levels did not associate with amyloid-β 1-42 , total tau, or phosphorylated tau. CSF auto-antibody levels correlated with performance on the Montreal Cognitive Assessment, even when controlled for CSF amyloidβ 1-42 . CSF hemoglobin levels, as a proxy for contamination of CSF by blood during lumbar puncture, did not influence these observations. Using recombinant α-synuclein with N- and C-terminal truncations, we found that CSF auto-antibodies target amino acids 100 through 120 of α-synuclein. We conclude that endogenous CSF auto-antibodies are significantly higher in PD patients as compared to HC, suggesting that they could indicate the presence of underlying synucleinopathy. These auto-antibodies associate with poor cognition, independently of CSF amyloidβ 1-42 ., and target a select C-terminal region of α-synuclein. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Concentrations of fine, ultrafine, and black carbon particles in auto-rickshaws in New Delhi, India
NASA Astrophysics Data System (ADS)
Apte, Joshua, S.; Kirchstetter, Thomas W.; Reich, Alexander, H.; Deshpande, Shyam J.; Kaushik, Geetanjali; Chel, Arvind; Marshall, Julian D.; Nazaroff, William W.
2011-08-01
Concentrations of air pollutants from vehicles are elevated along roadways, indicating that human exposure in transportation microenvironments may not be adequately characterized by centrally located monitors. We report results from ˜180 h of real-time measurements of fine particle and black carbon mass concentration (PM 2.5, BC) and ultrafine particle number concentration (PN) inside a common vehicle, the auto-rickshaw, in New Delhi, India. Measured exposure concentrations are much higher in this study (geometric mean for ˜60 trip-averaged concentrations: 190 μg m -3 PM 2.5, 42 μg m -3 BC, 280 × 10 3 particles cm -3; GSD ˜1.3 for all three pollutants) than reported for transportation microenvironments in other megacities. In-vehicle concentrations exceeded simultaneously measured ambient levels by 1.5× for PM 2.5, 3.6× for BC, and 8.4× for PN. Short-duration peak concentrations (averaging time: 10 s), attributable to exhaust plumes of nearby vehicles, were greater than 300 μg m -3 for PM 2.5, 85 μg m -3 for BC, and 650 × 10 3 particles cm -3 for PN. The incremental increase of within-vehicle concentration above ambient levels—which we attribute to in- and near-roadway emission sources—accounted for 30%, 68% and 86% of time-averaged in-vehicle PM 2.5, BC and PN concentrations, respectively. Based on these results, we estimate that one's exposure during a daily commute by auto-rickshaw in Delhi is as least as large as full-day exposures experienced by urban residents of many high-income countries. This study illuminates an environmental health concern that may be common in many populous, low-income cities.
Kim, Young Baek; Choi, Bum Ho; Lim, Yong Hwan; Yoo, Ha Na; Lee, Jong Ho; Kim, Jin Hyeok
2011-02-01
In this study, pentacene organic thin film was prepared using newly developed organic material auto-feeding system integrated with linear cell and characterized. The newly developed organic material auto-feeding system consists of 4 major parts: reservoir, micro auto-feeder, vaporizer, and linear cell. The deposition of organic thin film could be precisely controlled by adjusting feeding rate, main tube size, position and size of nozzle. 10 nm thick pentacene thin film prepared on glass substrate exhibited high uniformity of 3.46% which is higher than that of conventional evaporation method using point cell. The continuous deposition without replenishment of organic material can be performed over 144 hours with regulated deposition control. The grain size of pentacene film which affect to mobility of OTFT, was controlled as a function of the temperature.
Telemetry Standards, IRIG Standard 106-17, Chapter 22, Network Based Protocol Suite
2017-07-01
ER Fiber media connections using 10 Gigabit Ethernet shall comply with IEEE 802.3-2012, Section 5, Clause 52. 22.2.1.1.4 Auto- Negotiation ...22.2.1.1.4.1 Copper Auto- Negotiation Copper media connections, as described in the preceding sections, shall support auto- negotiation of speed, duplex, and...flow control in the manner specified in IEEE 802.3-2012, Section 2, Clause 28. 22.2.1.1.4.2 Fiber Auto- Negotiation Gigabit and 10 Gigabit fiber
ERIC Educational Resources Information Center
Rains, Larry
This engine performance (emission control systems) module is one of a series of competency-based modules in the Missouri Auto Mechanics Curriculum Guide. Topics of this module's five units are: positive crankcase ventilation (PCV) and evaporative emission control systems; exhaust gas recirculation (EGR); air injection and catalytic converters;…
Valencia-Palomo, G; Rossiter, J A
2011-01-01
This paper makes two key contributions. First, it tackles the issue of the availability of constrained predictive control for low-level control loops. Hence, it describes how the constrained control algorithm is embedded in an industrial programmable logic controller (PLC) using the IEC 61131-3 programming standard. Second, there is a definition and implementation of a novel auto-tuned predictive controller; the key novelty is that the modelling is based on relatively crude but pragmatic plant information. Laboratory experiment tests were carried out in two bench-scale laboratory systems to prove the effectiveness of the combined algorithm and hardware solution. For completeness, the results are compared with a commercial proportional-integral-derivative (PID) controller (also embedded in the PLC) using the most up to date auto-tuning rules. Copyright © 2010 ISA. Published by Elsevier Ltd. All rights reserved.
Gill, R; McCabe, M J; Rosenspire, A J
2017-09-01
Mercury (Hg) has been implicated as a factor contributing to autoimmune disease in animal models and humans. However the mechanism by which this occurs has remained elusive. Since the discovery of B cells it has been appreciated by immunologists that during the normal course of B cell development, some immature B cells must be generated that produce immunoglobulin reactive to self-antigens (auto-antibodies). However in the course of normal development, the vast majority of immature auto-reactive B cells are prevented from maturing by processes collectively known as tolerance. Autoimmune disease arises when these mechanisms of tolerance are disrupted. In the B cell compartment, it is firmly established that tolerance depends in part upon negative selection of self-reactive immature (transitional type 1) B cells. In these cells negative selection depends upon signals generated by the B Cell Receptor (BCR), in the sense that those T1 B cells who's BCRs most strongly bind to, and so generate the strongest signals to self-antigens are neutralized. In this report we have utilized multicolor phosphoflow cytometry to show that in immature T1 B cells Hg attenuates signal generation by the BCR through mechanisms that may involve Lyn, a key tyrosine kinase in the BCR signal transduction pathway. We suggest that exposure to low, environmentally relevant levels of Hg, disrupts tolerance by interfering with BCR signaling in immature B cells, potentially leading to the appearance of mature auto-reactive B cells which have the ability to contribute to auto-immune disease. Copyright © 2017 Elsevier Inc. All rights reserved.
Myers, Regina M; Hill, Brian T; Shaw, Bronwen E; Kim, Soyoung; Millard, Heather R; Battiwalla, Minoo; Majhail, Navneet S; Buchbinder, David; Lazarus, Hillard M; Savani, Bipin N; Flowers, Mary E D; D'Souza, Anita; Ehrhardt, Matthew J; Langston, Amelia; Yared, Jean A; Hayashi, Robert J; Daly, Andrew; Olsson, Richard F; Inamoto, Yoshihiro; Malone, Adriana K; DeFilipp, Zachariah; Margossian, Steven P; Warwick, Anne B; Jaglowski, Samantha; Beitinjaneh, Amer; Fung, Henry; Kasow, Kimberly A; Marks, David I; Reynolds, Jana; Stockerl-Goldstein, Keith; Wirk, Baldeep; Wood, William A; Hamadani, Mehdi; Satwani, Prakash
2018-02-15
Autologous hematopoietic cell transplantation (auto-HCT) is a standard therapy for relapsed classic Hodgkin lymphoma (cHL) and diffuse large B-cell lymphoma (DLBCL); however, long-term outcomes are not well described. This study analyzed survival, nonrelapse mortality, late effects, and subsequent malignant neoplasms (SMNs) in 1617 patients who survived progression-free for ≥2 years after auto-HCT for cHL or DLBCL between 1990 and 2008. The median age at auto-HCT was 40 years; the median follow-up was 10.6 years. The 5-year overall survival rate was 90% (95% confidence interval [CI], 87%-92%) for patients with cHL and 89% (95% CI, 87%-91%) for patients with DLBCL. The risk of late mortality in comparison with the general population was 9.6-fold higher for patients with cHL (standardized mortality ratio [SMR], 9.6) and 3.4-fold higher for patients with DLBCL (SMR, 3.4). Relapse accounted for 44% of late deaths. At least 1 late effect was reported for 9% of the patients. A total of 105 SMNs were confirmed: 44 in the cHL group and 61 in the DLBCL group. According to a multivariate analysis, older age, male sex, a Karnofsky score < 90, total body irradiation (TBI) exposure, and a higher number of lines of chemotherapy before auto-HCT were risk factors for overall mortality in cHL. Risk factors in DLBCL were older age and TBI exposure. A subanalysis of 798 adolescent and young adult patients mirrored the outcomes of the overall study population. Despite generally favorable outcomes, 2-year survivors of auto-HCT for cHL or DLBCL have an excess late-mortality risk in comparison with the general population and experience an assortment of late complications. Cancer 2018;124:816-25. © 2017 American Cancer Society. © 2017 American Cancer Society.
Finley, Brent L; Pierce, Jennifer S; Paustenbach, Dennis J; Scott, Laura L F; Lievense, Laura; Scott, Paul K; Galbraith, David A
2012-10-01
Until the 1980s, chrysotile asbestos was a component of automotive brakes manufactured in the US. The current OSHA Bulletin (2006) for brake repair cites a single study (Lemen, 2004) which concluded that the number of mesothelioma cases reported in the literature in "end-product users of friction materials" indicated an asbestos-related risk for auto mechanics. However, Lemen (2004) did not compare the reported number of cases to an "expected" value, even though pleural mesothelioma occurs in the general population in the absence of asbestos exposure. We compare the number of malignant pleural mesothelioma (MPM) cases reported in the US literature among auto mechanics between 1975-2007 to an expected value derived from estimated numbers of current and former auto mechanics. A total of 106 cases categorized as mesothelioma or malignant neoplasm of the pleura were found in the literature. Using background incidence rates for MPM of two and three cases per million individuals per year, we estimated that a range of 278-515 cases of non-asbestos-related MPM, respectively, would have occurred in current or former auto mechanics from 1975-2007. Our findings are consistent with the numerous epidemiology studies that have found no increased risk of MPM in auto mechanics. Copyright © 2012 Elsevier Inc. All rights reserved.
[Design of blood-pressure parameter auto-acquisition circuit].
Chen, Y P; Zhang, D L; Bai, H W; Zhang, D A
2000-02-01
This paper presents the realization and design of a kind of blood-pressure parameter auto-acquisition circuit. The auto-acquisition of blood-pressure parameter controlled by 89C2051 single chip microcomputer is accomplished by collecting and processing the driving signal of LCD. The circuit that is successfully applied in the home unit of telemedicine system has the simple and reliable properties.
Krakow, Barry; Ulibarri, Victor A; McIver, Natalia D; Nadorff, Michael R
2016-09-29
Evidence indicates that behavioral or drug therapy may not target underlying pathophysiologic mechanisms for chronic insomnia, possibly due to previously unrecognized high rates (30%-90%) of sleep apnea in chronic insomnia patients. Although treatment studies with positive airway pressure (PAP) demonstrate decreased severity of chronic sleep maintenance insomnia in patients with co-occurring sleep apnea, sleep-onset insomnia has not shown similar results. We hypothesized advanced PAP technology would be associated with decreased sleep-onset insomnia severity in a sample of predominantly psychiatric patients with comorbid sleep apnea. We reviewed charts of 74 severe sleep-onset insomnia patients seen from March 2011 to August 2015, all meeting American Academy of Sleep Medicine Work Group criteria for a chronic insomnia disorder and all affirming behavioral and psychological origins for insomnia (averaging 10 of 18 indicators/patient), as well as averaging 2 or more psychiatric symptoms or conditions: depression (65.2%), anxiety (41.9%), traumatic exposure (35.1%), claustrophobia (29.7%), panic attacks (28.4%), and posttraumatic stress disorder (20.3%). All patients failed continuous or bilevel PAP and were manually titrated with auto-adjusting PAP modes (auto-bilevel and adaptive-servo ventilation). At 1-year follow-up, patients were compared through nonrandom assignment on the basis of a PAP compliance metric of > 20 h/wk (56 PAP users) versus < 20 h/wk (18 partial PAP users). PAP users showed significantly greater decreases in global insomnia severity (Hedges' g = 1.72) and sleep-onset insomnia (g = 2.07) compared to partial users (g = 1.04 and 0.91, respectively). Both global and sleep-onset insomnia severity decreased below moderate levels in PAP users compared to partial users whose outcomes persisted at moderately severe levels. In a nonrandomized controlled retrospective study, advanced PAP technology (both auto-bilevel and adaptive servo-ventilation) were associated with large decreases in insomnia severity for sleep-onset insomnia patients who strongly believed psychological factors caused their sleeplessness. PAP treatment of sleep-onset insomnia merits further investigation. © Copyright 2016 Physicians Postgraduate Press, Inc.
Anti-neuropeptide Y plasma immunoglobulins in relation to mood and appetite in depressive disorder.
Garcia, Frederico D; Coquerel, Quentin; do Rego, Jean-Claude; Cravezic, Aurore; Bole-Feysot, Christine; Kiive, Evelyn; Déchelotte, Pierre; Harro, Jaanus; Fetissov, Sergueï O
2012-09-01
Depression and eating disorders are frequently associated, but the molecular pathways responsible for co-occurrence of altered mood, appetite and body weight are not yet fully understood. Neuropeptide Y (NPY) has potent antidepressant and orexigenic properties and low central NPY levels have been reported in major depression. In the present study, we hypothesized that in patients with major depression alteration of mood, appetite and body weight may be related to NPY-reactive autoantibodies (autoAbs). To test this hypothesis, we compared plasma levels and affinities of NPY-reactive autoAbs between patients with major depression and healthy controls. Then, to evaluate if changes of NPY autoAb properties can be causally related to altered mood and appetite, we developed central and peripheral passive transfer models of human autoAbs in mice and studied depressive-like behavior in forced-swim test and food intake. We found that plasma levels of NPY IgG autoAbs were lower in patients with moderate but not with mild depression correlating negatively with the Montgomery-Åsberg Depression Rating Scale scores and with immobility time of the forced-swim test in mice after peripheral injection of autoAbs. No significant differences in NPY IgG autoAb affinities between patients with depression and controls were found, but higher affinity of IgG autoAbs for NPY was associated with lower body mass index and prevented NPY-induced orexigenic response in mice after their central injection. These data suggest that changes of plasma levels of anti-NPY autoAbs are relevant to altered mood, while changes of their affinity may participate in altered appetite and body weight in patients with depressive disorder. Copyright © 2012 Elsevier Ltd. All rights reserved.
New Mexico: Bernalillo County, Albuquerque (A Former EPA CARE Project)
The Bernalillo County Office of Environmental Health (BCEH) will help the South Valley neighborhood reduce health risks attributed to benzene and heavy metal exposures by conducting an environmental assessment of gasoline stations and auto dismantlers,
A Comparative Study of Alternative Controls and Displays for by the Severely Physically Handicapped
NASA Technical Reports Server (NTRS)
Williams, D.; Simpson, C.; Barker, M.
1984-01-01
A modification of a row/column scanning system was investigated in order to increase the speed and accuracy with which communication aids can be accessed with one or two switches. A selection algorithm was developed and programmed in BASIC to automatically select individuals with the characteristic difficulty in controlling time dependent control and display systems. Four systems were compared: (1) row/column directed scan (2 switches); (2) row/column auto scan (1 switch); (3) row auto scan (1 switch); and (4) column auto scan (1 switch). For this sample population, there were no significant differences among systems for scan time to select the correct target. The row/column auto scan system resulted in significantly more errors than any of the other three systems. Thus, the most widely prescribed system for severely physically disabled individuals turns out for this group to have a higher error rate and no faster communication rate than three other systems that have been considered inappropriate for this group.
Code of Federal Regulations, 2013 CFR
2013-04-01
... under common ownership or control. An example would be a major auto maker which has dozens of automobile... “employer”, the auto maker. (b) Plant closing. The term “plant closing” means the permanent or temporary...
Code of Federal Regulations, 2014 CFR
2014-04-01
... under common ownership or control. An example would be a major auto maker which has dozens of automobile... “employer”, the auto maker. (b) Plant closing. The term “plant closing” means the permanent or temporary...
Code of Federal Regulations, 2012 CFR
2012-04-01
... under common ownership or control. An example would be a major auto maker which has dozens of automobile... “employer”, the auto maker. (b) Plant closing. The term “plant closing” means the permanent or temporary...
EFFECTS OF BRANCHING IN A COMPUTER-CONTROLLED AUTO-INSTRUCTIONAL DEVICE.
ERIC Educational Resources Information Center
COULSON, JOHN E.; AND OTHERS
A STUDY ON THE EFFECTIVENESS OF USING BOTH THE STUDENT'S ERRORS ON TRAINING ITEMS AND HIS OWN EVALUATION OF HIS LEARNING PROGRESS WAS PRESENTED. TWO GROUPS OF 15 HIGH SCHOOL STUDENTS WERE GIVEN AUTOMATED INSTRUCTION ON LOGIC BY MEANS OF A FLEXIBLE SEQUENCE, COMPUTER-CONTROLLED AUTO-INSTRUCTIONAL DEVICE. ONE GROUP WAS DESIGNATED THE FIXED-SEQUENCE…
Holistic Framework For Establishing Interoperability of Heterogeneous Software Development Tools
2003-06-01
cannot be obtained or is zero while in autocontrol , CARA will terminate auto-control 1.637 16 5 FEAT12 EMF Present, Log Manual Mode If back EMF...auto- control mode a ’Terminate Autocontrol ’ button should be made available. 16.37 9 5 300 FEAT Tag Name Requirement Text AHP Priority Rqts
Tiberkevich, Vasil S.; Khymyn, Roman S.; Tang, Hong X.; Slavin, Andrei N.
2014-01-01
For auto-oscillators of different nature (e.g. active cells in a human heart under the action of a pacemaker, neurons in brain, spin-torque nano-oscillators, micro and nano-mechanical oscillators, or generating Josephson junctions) a critically important property is their ability to synchronize with each other. The synchronization properties of an auto oscillator are directly related to its sensitivity to external signals. Here we demonstrate that a non-isochronous (having generation frequency dependent on the amplitude) auto-oscillator with delayed feedback can have an extremely high sensitivity to external signals and unusually large width of the phase-locking band near the boundary of the stable auto-oscillation regime. This property could be used for the development of synchronized arrays of non-isochronous auto-oscillators in physics and engineering, and, for instance, might bring a better fundamental understanding of ways to control a heart arrythmia in medicine. PMID:24464086
Muratori, Pietro; Pisano, Simone; Milone, Annarita; Masi, Gabriele
2017-01-15
The Child Behavior Checklist Dysregulation Profile (CBCL-DP), (high scores in Anxious/Depressed, Attention Problems, and Aggressive Behavior subscales), has been related to poor emotional and behavioral self-regulation in children and adolescents. Our aim is to evaluate if it may be associated with auto-aggression in youth with oppositional defiant disorder (ODD). Method In 72 consecutively referred youths with ODD, emotional dysregulation was assessed with the CBCL-DP, auto-aggression and physical aggression against other persons with the Modified Overt Aggression Scale. Regression analysis showed that greater higher CBCL-DP scores were associated to higher levels of auto-aggression, even when controlling for the levels of physical aggression against others and CBCL Total score. The small sample size, the cross-sectional design, and the lack of a control group limit the generalization of our findings. Referred ODD youths with higher scores of CBCL-DP are more likely to present auto-aggression, besides aggression against others. The CBCL could improve the screening and detection of these high-risk patients. Copyright © 2016 Elsevier B.V. All rights reserved.
The performance of two automatic servo-ventilation devices in the treatment of central sleep apnea.
Javaheri, Shahrokh; Goetting, Mark G; Khayat, Rami; Wylie, Paul E; Goodwin, James L; Parthasarathy, Sairam
2011-12-01
This study was conducted to evaluate the therapeutic performance of a new auto Servo Ventilation device (Philips Respironics autoSV Advanced) for the treatment of complex central sleep apnea (CompSA). The features of autoSV Advanced include an automatic expiratory pressure (EPAP) adjustment, an advanced algorithm for distinguishing open versus obstructed airway apnea, a modified auto backup rate which is proportional to subject's baseline breathing rate, and a variable inspiratory support. Our primary aim was to compare the performance of the advanced servo-ventilator (BiPAP autoSV Advanced) with conventional servo-ventilator (BiPAP autoSV) in treating central sleep apnea (CSA). A prospective, multicenter, randomized, controlled trial. Five sleep laboratories in the United States. Thirty-seven participants were included. All subjects had full night polysomnography (PSG) followed by a second night continuous positive airway pressure (CPAP) titration. All had a central apnea index ≥ 5 per hour of sleep on CPAP. Subjects were randomly assigned to 2 full-night PSGs while treated with either the previously marketed autoSV, or the new autoSV Advanced device. The 2 randomized sleep studies were blindly scored centrally. Across the 4 nights (PSG, CPAP, autoSV, and autoSV Advanced), the mean ± 1 SD apnea hypopnea indices were 53 ± 23, 35 ± 20, 10 ± 10, and 6 ± 6, respectively; indices for CSA were 16 ± 19, 19 ± 18, 3 ± 4, and 0.6 ± 1. AutoSV Advanced was more effective than other modes in correcting sleep related breathing disorders. BiPAP autoSV Advanced was more effective than conventional BiPAP autoSV in the treatment of sleep disordered breathing in patients with CSA.
Enhancing Price Response Programs through Auto-DR: California's 2007 Implementation Experience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiliccote, Sila; Wikler, Greg; Chiu, Albert
2007-12-18
This paper describes automated demand response (Auto-DR) activities, an innovative effort in California to ensure that DR programs produce effective and sustainable impacts. Through the application of automation and communication technologies coupled with well-designed incentives and DR programs such as Critical Peak Pricing (CPP) and Demand Bidding (DBP), Auto-DR is opening up the opportunity for many different types of buildings to effectively participate in DR programs. We present the results of Auto-DR implementation efforts by the three California investor-owned utilities for the Summer of 2007. The presentation emphasizes Pacific Gas and Electric Company's (PG&E) Auto-DR efforts, which represents the largestmore » in the state. PG&E's goal was to recruit, install, test and operate 15 megawatts of Auto-DR system capability. We describe the unique delivery approaches, including optimizing the utility incentive structures designed to foster an Auto-DR service provider community. We also show how PG&E's Critical Peak Pricing (CPP) and Demand Bidding (DBP) options were called and executed under the automation platform. Finally, we show the results of the Auto-DR systems installed and operational during 2007, which surpassed PG&E's Auto-DR goals. Auto-DR is being implemented by a multi-disciplinary team including the California Investor Owned Utilities (IOUs), energy consultants, energy management control system vendors, the Lawrence Berkeley National Laboratory (LBNL), and the California Energy Commission (CEC).« less
Systemic Delivery of Atropine Sulfate by the MicroDose Dry-Powder Inhaler
Venkataramanan, R.; Hoffman, R.M.; George, M.P.; Petrov, A.; Richards, T.; Zhang, S.; Choi, J.; Gao, Y.Y.; Oakum, C.D.; Cook, R.O.; Donahoe, M.
2013-01-01
Abstract Background Inhaled atropine is being developed as a systemic and pulmonary treatment for the extended recovery period after chemical weapons exposure. We performed a pharmacokinetics study comparing inhaled atropine delivery using the MicroDose Therapeutx Dry Powder Inhaler (DPIA) with intramuscular (IM) atropine delivery via auto-injector (AUTO). Methods The MicroDose DPIA utilizes a novel piezoelectric system to aerosolize drug and excipient from a foil dosing blister. Subjects inhaled a 1.95-mg atropine sulfate dose from the dry powder inhaler on one study day [5 doses×0.4 mg per dose (nominal) delivered over 12 min] and received a 2-mg IM injection via the AtroPen® auto-injector on another. Pharmacokinetics, pharmacodynamic response, and safety were studied for 12 hr. Results A total of 17 subjects were enrolled. All subjects completed IM dosing. One subject did not perform inhaled delivery due to a skin reaction from the IM dose. Pharmacokinetic results were as follows: area under the curve concentration, DPIA=20.1±5.8, AUTO=23.7±4.9 ng hr/mL (means±SD); maximum concentration reached, DPIA=7.7±3.5, AUTO=11.0±3.8 ng/mL; time to reach maximum concentration, DPIA=0.25±0.47, AUTO=0.19±0.23 hr. Pharmacodynamic results were as follows: maximum increase in heart rate, DPIA=18±12, AUTO=23±13 beats/min; average change in 1-sec forced expiratory volume at 30 min, DPIA=0.16±0.22 L, AUTO=0.11±0.29 L. The relative bioavailability for DPIA was 87% (based on output dose). Two subjects demonstrated allergic responses: one to the first dose (AUTO), which was mild and transient, and one to the second dose (DPIA), which was moderate in severity, required treatment with oral and intravenous (IV) diphenhydramine and IV steroids, and lasted more than 7 days. Conclusions Dry powder inhalation is a highly bioavailable route for attaining rapid and consistent systemic concentrations of atropine. PMID:22691110
Systemic delivery of atropine sulfate by the MicroDose Dry-Powder Inhaler.
Corcoran, T E; Venkataramanan, R; Hoffman, R M; George, M P; Petrov, A; Richards, T; Zhang, S; Choi, J; Gao, Y Y; Oakum, C D; Cook, R O; Donahoe, M
2013-02-01
Inhaled atropine is being developed as a systemic and pulmonary treatment for the extended recovery period after chemical weapons exposure. We performed a pharmacokinetics study comparing inhaled atropine delivery using the MicroDose Therapeutx Dry Powder Inhaler (DPIA) with intramuscular (IM) atropine delivery via auto-injector (AUTO). The MicroDose DPIA utilizes a novel piezoelectric system to aerosolize drug and excipient from a foil dosing blister. Subjects inhaled a 1.95-mg atropine sulfate dose from the dry powder inhaler on one study day [5 doses × 0.4 mg per dose (nominal) delivered over 12 min] and received a 2-mg IM injection via the AtroPen® auto-injector on another. Pharmacokinetics, pharmacodynamic response, and safety were studied for 12 hr. A total of 17 subjects were enrolled. All subjects completed IM dosing. One subject did not perform inhaled delivery due to a skin reaction from the IM dose. Pharmacokinetic results were as follows: area under the curve concentration, DPIA=20.1±5.8, AUTO=23.7±4.9 ng hr/mL (means±SD); maximum concentration reached, DPIA=7.7±3.5, AUTO=11.0±3.8 ng/mL; time to reach maximum concentration, DPIA=0.25±0.47, AUTO=0.19±0.23 hr. Pharmacodynamic results were as follows: maximum increase in heart rate, DPIA=18±12, AUTO=23±13 beats/min; average change in 1-sec forced expiratory volume at 30 min, DPIA=0.16±0.22 L, AUTO=0.11±0.29 L. The relative bioavailability for DPIA was 87% (based on output dose). Two subjects demonstrated allergic responses: one to the first dose (AUTO), which was mild and transient, and one to the second dose (DPIA), which was moderate in severity, required treatment with oral and intravenous (IV) diphenhydramine and IV steroids, and lasted more than 7 days. Dry powder inhalation is a highly bioavailable route for attaining rapid and consistent systemic concentrations of atropine.
Latshang, Tsogyal D; Nussbaumer-Ochsner, Yvonne; Henn, Rahel M; Ulrich, Silvia; Lo Cascio, Christian M; Ledergerber, Bruno; Kohler, Malcolm; Bloch, Konrad E
2012-12-12
Many patients with obstructive sleep apnea syndrome (OSA) living near sea level travel to altitude, but this may expose them to hypoxemia and exacerbation of sleep apnea. The treatment in this setting is not established. To evaluate whether acetazolamide and autoadjusted continuous positive airway pressure (autoCPAP) control breathing disturbances in OSA patients at altitude. Randomized, placebo-controlled, double-blind, crossover trial involving 51 patients with OSA living below an altitude of 800 m and receiving CPAP therapy who underwent studies at a university hospital at 490 m and resorts in Swiss mountain villages at 1630 m and 2590 m in summer 2009. Patients were studied during 2 sojourns of 3 days each in mountain villages, 2 days at 1630 m, 1 day at 2590 m, separated by a 2-week washout period at less than 800 m. At altitude, patients either took acetazolamide (750 mg/d) or placebo in addition to autoCPAP. Primary outcomes were nocturnal oxygen saturation and the apnea/hypopnea index; secondary outcomes were sleep structure, vigilance, symptoms, adverse effects, and exercise performance. Acetazolamide and autoCPAP treatment was associated with higher nocturnal oxygen saturation at 1630 m and 2590 m than placebo and autoCPAP: medians, 94% (interquartile range [IQR], 93%-95%) and 91% (IQR, 90%-92%) vs 93% (IQR, 92%-94%) and 89% (IQR, 87%-91%), respectively. Median increases were 1.0% (95% CI, 0.3%-1.0%) and 2.0% (95% CI, 2.0%-2.0). Median night-time spent with oxygen saturation less than 90% at 2590 m was 13% (IQR, 2%-38%) vs 57% (IQR, 28%-82%; P < .001). Acetazolamide and autoCPAP resulted in better control of sleep apnea at 1630 m and 2590 m than placebo and autoCPAP: median apnea/hypopnea index was 5.8 events per hour (5.8/h) (IQR, 3.0/h-10.1/h) and 6.8/h (IQR, 3.5/h-10.1/h) vs 10.7/h (IQR, 5.1/h-17.7/h) and 19.3/h (IQR, 9.3/h-29.0/h), respectively; median reduction was 3.2/h (95% CI, 1.3/h-7.5/h) and 9.2 (95% CI, 5.1/h-14.6/h). Among patients with OSA spending 3 days at moderately elevated altitude, a combination of acetazolamide and autoCPAP therapy, compared with autoCPAP alone, resulted in improvement in nocturnal oxygen saturation and apnea/hypopnea index. clinicaltrials.gov Identifier: NCT00928655.
Analysis on the workspace of palletizing robot based on AutoCAD
NASA Astrophysics Data System (ADS)
Li, Jin-quan; Zhang, Rui; Guan, Qi; Cui, Fang; Chen, Kuan
2017-10-01
In this paper, a four-degree-of-freedom articulated palletizing robot is used as the object of research. Based on the analysis of the overall configuration of the robot, the kinematic mathematical model is established by D-H method to figure out the workspace of the robot. In order to meet the needs of design and analysis, using AutoCAD secondary development technology and AutoLisp language to develop AutoCAD-based 2D and 3D workspace simulation interface program of palletizing robot. At last, using AutoCAD plugin, the influence of structural parameters on the shape and position of the working space is analyzed when the structure parameters of the robot are changed separately. This study laid the foundation for the design, control and planning of palletizing robots.
Preliminary Design of a Modular Unmanned Research Vehicle. Volume 1. System Design Document
1988-12-01
providing con- munications and restraint. 1-5 Tethered unpowered vehicle - an airplane-like body tether-mounted to an automobile , the auto providing...the velocity by towing. Auto-mounted vehicle - an airplane-like body rigidly mounted external to an automobile , the auto providing the velocity. Rail...accordingly. Based on this experiment, the MURV flight control system must be flexible in two ways: it should be reprogrammable for varying experimental
NASA Astrophysics Data System (ADS)
Tian, Yi; Chen, Mahao; Kong, Jun
2009-02-01
With the online z-axis tube current modulation (OZTCM) technique proposed by this work, full automatic exposure control (AEC) for CT systems could be realized with online feedback not only for angular tube current modulation (TCM) but also for z-axis TCM either. Then the localizer radiograph was not required for TCM any more. OZTCM could be implemented with 2 schemes as attenuation based μ-OZTCM and image noise level based μ-OZTCM. Respectively the maximum attenuation of projection readings and standard deviation of reconstructed images can be used to modulate the tube current level in z-axis adaptively for each half (180 degree) or full (360 degree) rotation. Simulation results showed that OZTCM achieved better noise level than constant tube current scan case by using same total dose in mAs. The OZTCM can provide optimized base tube current level for angular TCM to realize an effective auto exposure control when localizer radiograph is not available or need to be skipped for simplified scan protocol in case of emergency procedure or children scan, etc.
Auto-Regulatory RNA Editing Fine-Tunes mRNA Re-Coding and Complex Behaviour in Drosophila
Savva, Yiannis A.; Jepson, James E.C; Sahin, Asli; Sugden, Arthur U.; Dorsky, Jacquelyn S.; Alpert, Lauren; Lawrence, Charles; Reenan, Robert A.
2014-01-01
Auto-regulatory feedback loops are a common molecular strategy used to optimize protein function. In Drosophila many mRNAs involved in neuro-transmission are re-coded at the RNA level by the RNA editing enzyme dADAR, leading to the incorporation of amino acids that are not directly encoded by the genome. dADAR also re-codes its own transcript, but the consequences of this auto-regulation in vivo are unclear. Here we show that hard-wiring or abolishing endogenous dADAR auto-regulation dramatically remodels the landscape of re-coding events in a site-specific manner. These molecular phenotypes correlate with altered localization of dADAR within the nuclear compartment. Furthermore, auto-editing exhibits sexually dimorphic patterns of spatial regulation and can be modified by abiotic environmental factors. Finally, we demonstrate that modifying dAdar auto-editing affects adaptive complex behaviors. Our results reveal the in vivo relevance of auto-regulatory control over post-transcriptional mRNA re-coding events in fine-tuning brain function and organismal behavior. PMID:22531175
Distributed Fair Auto Rate Medium Access Control for IEEE 802.11 Based WLANs
NASA Astrophysics Data System (ADS)
Zhu, Yanfeng; Niu, Zhisheng
Much research has shown that a carefully designed auto rate medium access control can utilize the underlying physical multi-rate capability to exploit the time-variation of the channel. In this paper, we develop a simple analytical model to elucidate the rule that maximizes the throughput of RTS/CTS based multi-rate wireless local area networks. Based on the discovered rule, we propose two distributed fair auto rate medium access control schemes called FARM and FARM+ from the view-point of throughput fairness and time-share fairness, respectively. With the proposed schemes, after receiving a RTS frame, the receiver selectively returns the CTS frame to inform the transmitter the maximum feasible rate probed by the signal-to-noise ratio of the received RTS frame. The key feature of the proposed schemes is that they are capable of maintaining throughput/time-share fairness in asymmetric situation where the distribution of SNR varies with stations. Extensive simulation results show that the proposed schemes outperform the existing throughput/time-share fair auto rate schemes in time-varying channel conditions.
Laser-assisted homogeneous charge ignition in a constant volume combustion chamber
NASA Astrophysics Data System (ADS)
Srivastava, Dhananjay Kumar; Weinrotter, Martin; Kofler, Henrich; Agarwal, Avinash Kumar; Wintner, Ernst
2009-06-01
Homogeneous charge compression ignition (HCCI) is a very promising future combustion concept for internal combustion engines. There are several technical difficulties associated with this concept, and precisely controlling the start of auto-ignition is the most prominent of them. In this paper, a novel concept to control the start of auto-ignition is presented. The concept is based on the fact that most HCCI engines are operated with high exhaust gas recirculation (EGR) rates in order to slow-down the fast combustion processes. Recirculated exhaust gas contains combustion products including moisture, which has a relative peak of the absorption coefficient around 3 μm. These water molecules absorb the incident erbium laser radiations ( λ=2.79 μm) and get heated up to expedite ignition. In the present experimental work, auto-ignition conditions are locally attained in an experimental constant volume combustion chamber under simulated EGR conditions. Taking advantage of this feature, the time when the mixture is thought to "auto-ignite" could be adjusted/controlled by the laser pulse width optimisation, followed by its resonant absorption by water molecules present in recirculated exhaust gas.
Kamal, Atif; Cincinelli, Alessandra; Martellini, Tania; Palchetti, Ilaria; Bettazzi, Francesca; Malik, Riffat Naseem
2016-01-01
This study presents the analyses of urinary biomarkers (1-OHPyr, α- and β-naphthols) of polycyclic aromatic hydrocarbons (PAHs) exposure and biomarkers of effect (i.e. blood parameters) in petroleum-refinery workers (RFs) and auto-repair workers (MCs). Exposed subjects had higher concentrations of white blood cell (WBC) count than control subjects (CN) subjects (5.31 × 10(3) μL(-1) in exposed vs. 5.15 × 10(3) μL(-1) in CN subjects), while the biomarker of oxidative DNA damage (8-OHdG) was significantly higher in MCs. The exposure among these two cohorts could be influenced by the ambience of the workplaces; in fact, MCs' shops are relatively damp and enclosed workplaces in comparison with the indoor environment of refineries. PAHs in the dust samples from mechanical workshops probably originated from mixed sources (traffic exhaust and petroleum spills), while the incremental lifetime cancer risk (ILCR) for MCs showed moderate-to-low cancer risk from exposure to dust-bound PAHs. The study shows that increasing PAH exposure can be traced in MC workstations and needs to be investigated for the safety of public health.
40 CFR 52.1174 - Control strategy: Ozone.
Code of Federal Regulations, 2010 CFR
2010-07-01
... oxides of nitrogen requirements for conformity and new source review. Theses are required by sections 176... architectural, industrial, and maintenance coatings rule; auto body refinisher self-certification audit program... architectural, industrial, and maintenance coatings rule; auto body refinisher self-certification audit program...
40 CFR 52.1174 - Control strategy: Ozone.
Code of Federal Regulations, 2012 CFR
2012-07-01
... oxides of nitrogen requirements for conformity and new source review. Theses are required by sections 176... architectural, industrial, and maintenance coatings rule; auto body refinisher self-certification audit program... architectural, industrial, and maintenance coatings rule; auto body refinisher self-certification audit program...
40 CFR 52.1174 - Control strategy: Ozone.
Code of Federal Regulations, 2013 CFR
2013-07-01
... oxides of nitrogen requirements for conformity and new source review. Theses are required by sections 176... architectural, industrial, and maintenance coatings rule; auto body refinisher self-certification audit program... architectural, industrial, and maintenance coatings rule; auto body refinisher self-certification audit program...
40 CFR 52.1174 - Control strategy: Ozone.
Code of Federal Regulations, 2014 CFR
2014-07-01
... oxides of nitrogen requirements for conformity and new source review. Theses are required by sections 176... architectural, industrial, and maintenance coatings rule; auto body refinisher self-certification audit program... architectural, industrial, and maintenance coatings rule; auto body refinisher self-certification audit program...
40 CFR 52.1174 - Control strategy: Ozone.
Code of Federal Regulations, 2011 CFR
2011-07-01
... oxides of nitrogen requirements for conformity and new source review. Theses are required by sections 176... architectural, industrial, and maintenance coatings rule; auto body refinisher self-certification audit program... architectural, industrial, and maintenance coatings rule; auto body refinisher self-certification audit program...
NORDA’s Pattern Analysis Laboratory: Current Contributions to Naval Mapping, Charting, and Geodesy
1989-04-01
magnetic observatories (McLeod, 1988). Using system integrates a suite of sensors and control devices the PAL’s VAX 11/780, spherical harmonic models to...DJAO:[FPS]*.OLB 5. Miscellaneous Utilities CALENDAR (NORDA events) 780 $ CALENDAR (menu-driven) DIALER modem controller 780 $ R AUTO DIAL:DIALER DTC...Utilities CALENDAR (NORDA events) 780 CALENDAR (menu-driven) DIALER modem controller 780 $ R AUTO DIAL:DIALER DTC Desk Top Calendar 780 $ DTC (menu-driven
Scarr, Daniel; Lovblom, Leif E; Ostrovski, Ilia; Kelly, Dylan; Wu, Tong; Farooqi, Mohammed A; Halpern, Elise M; Ngo, Mylan; Ng, Eduardo; Orszag, Andrej; Bril, Vera; Perkins, Bruce A
2017-06-01
Quantification of corneal nerve fiber length (CNFL) by in vivo corneal confocal microscopy represents a promising diabetic neuropathy biomarker, but applicability is limited by resource-intensive image analysis. We aimed to evaluate, in cross-sectional analysis of non-diabetic controls and patients with type 1 and type 2 diabetes with and without neuropathy, the agreement between manual and automated analysis protocols. Sixty-eight controls, 139 type 1 diabetes, and 249 type 2 diabetes participants underwent CNFL measurement (N=456). Neuropathy status was determined by clinical and electrophysiological criteria. CNFL was determined by manual (CNFL Manual , reference standard) and automated (CNFL Auto ) protocols, and results were compared for correlation and agreement using Spearman coefficients and the method of Bland and Altman (CNFL Manual subtracted from CNFL Auto ). Participants demonstrated broad variability in clinical characteristics associated with neuropathy. The mean age, diabetes duration, and HbA1c were 53±18years, 15.9±12.6years, and 7.4±1.7%, respectively, and 218 (56%) individuals with diabetes had neuropathy. Mean CNFL Manual was 15.1±4.9mm/mm 2 , and mean CNFL Auto was 10.5±3.7mm/mm 2 (CNFL Auto underestimation bias, -4.6±2.6mm/mm 2 corresponding to -29±17%). Percent bias was similar across non-diabetic controls (-33±12%), type 1 (-30±20%), and type 2 diabetes (-28±16%) subgroups (ANOVA, p=0.068), and similarly in diabetes participants with and without neuropathy. Levels of CNFL Auto and CNFL Manual were both inversely associated with neuropathy status. Although CNFL Auto substantially underestimated CNFL Manual , its bias was non-differential between diverse patient groups and its relationship with neuropathy status was preserved. Determination of diagnostic thresholds specific to CNFL Auto should be pursued in diagnostic studies of diabetic neuropathy. Copyright © 2016 Elsevier Inc. All rights reserved.
High density growth of T7 expression strains with auto-induction option
Studier, F. William
2010-07-20
A bacterial growth medium for promoting auto-induction of transcription of cloned DNA in cultures of bacterial cells grown batchwise is disclosed. The transcription is under the control of a lac repressor. Also disclosed is a bacterial growth medium for improving the production of a selenomethionine-containing protein or polypeptide in a bacterial cell, the protein or polypeptide being produced by recombinant DNA techniques from a lac or T7lac promoter, the bacterial cell encoding a vitamin B12-dependent homocysteine methylase. Finally, disclosed is a bacterial growth medium for suppressing auto-induction of expression in cultures of bacterial cells grown batchwise, said transcription being under the control of lac repressor.
46 CFR 62.35-50 - Tabulated monitoring and safety control requirements for specific systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) (9) Remote/auto fill level High Auto trip or overflow arrangement Hi. press. leakage level High Bilge... CL.3 W.T. doors Open/closed Fire detection Machinery spaces Space on fire (9) Fire main Pressure Low...
Note: Digital laser frequency auto-locking for inter-satellite laser ranging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luo, Yingxin; Yeh, Hsien-Chi, E-mail: yexianji@mail.hust.edu.cn; Li, Hongyin
2016-05-15
We present a prototype of a laser frequency auto-locking and re-locking control system designed for laser frequency stabilization in inter-satellite laser ranging system. The controller has been implemented on field programmable gate arrays and programmed with LabVIEW software. The controller allows initial frequency calibrating and lock-in of a free-running laser to a Fabry-Pérot cavity. Since it allows automatic recovery from unlocked conditions, benefit derives to automated in-orbit operations. Program design and experimental results are demonstrated.
Prompting Technology and Persons With Dementia: The Significance of Context and Communication.
Braley, Rachel; Fritz, Rochelle; Van Son, Catherine R; Schmitter-Edgecombe, Maureen
2018-06-12
Smart home auto-prompting has the potential to increase the functional independence of persons with dementia (PWDs) and decrease caregiver burden as instrumental activities of daily living (IADLs) are completed at home. To improve prompting technologies, we sought to inductively understand how PWDs responded to auto-prompting while performing IADL tasks. Fifteen PWDs completed eight IADLs in a smart home testbed and received a hierarchy of verbal auto-prompts (indirect, direct, multimodal) as needed for task completion. Two researchers viewed archived videos and recorded the observed behaviors of the PWDs and their reflections watching the PWDs. Using qualitative descriptive methods, an interdisciplinary analytic team reviewed transcripts and organized data into themes using content analysis. Context and Communication emerged as the major themes, suggesting that positive user experiences will require auto-prompting systems to account for a multitude of contextual factors (individual and environmental) such as level of cognitive impairment, previous exposure to task, and familiarity of environment. Communicating with another human rather than an automated prompting system may be important if individuals begin to exhibit signs of stress while completing activities. Additional work is needed to create auto-prompting systems that provide specific, personalized, and flexible prompts. Holistic conceptualization of "successful task completion" is needed and a positive end-user experience will be key to utility. Such systems will benefit from including positive reinforcement, training, and exploration of how, and whether, direct human involvement can be minimized during the provision of in-home care.
Epidemiologic studies indicate that acute exposures to vehicular traffic and particulate matter (PM) air pollution are key causes of fatal cardiac arrhythmia, especially in those with preexisting cardiovascular disease. Researchers point to electrophysiologic dysfunction and auto...
RESEARCH PROJECT A: MAPPING DISPARITIES IN BIRTH OUTCOMES
Fukao, Mari; Kawamoto, Kiyosumi; Matsuzawa, Hiroaki; Honda, Osamu; Iwaki, Takeshi; Doi, Tsukasa
2015-01-01
We aimed to optimize the exposure conditions in the acquisition of soft-tissue images using dual-energy subtraction chest radiography with a direct-conversion flat-panel detector system. Two separate chest images were acquired at high- and low-energy exposures with standard or thick chest phantoms. The high-energy exposure was fixed at 120 kVp with the use of an auto-exposure control technique. For the low-energy exposure, the tube voltages and entrance surface doses ranged 40-80 kVp and 20-100 % of the dose required for high-energy exposure, respectively. Further, a repetitive processing algorithm was used for reduction of the image noise generated by the subtraction process. Seven radiology technicians ranked soft-tissue images, and these results were analyzed using the normalized-rank method. Images acquired at 60 kVp were of acceptable quality regardless of the entrance surface dose and phantom size. Using a repetitive processing algorithm, the minimum acceptable doses were reduced from 75 to 40 % for the standard phantom and to 50 % for the thick phantom. We determined that the optimum low-energy exposure was 60 kVp at 50 % of the dose required for the high-energy exposure. This allowed the simultaneous acquisition of standard radiographs and soft-tissue images at 1.5 times the dose required for a standard radiograph, which is significantly lower than the values reported previously.
Controls for and constraints on auto-shaping
Bilbrey, John; Winokur, Stephen
1973-01-01
Auto-shaping the pigeon's key-peck response was examined as a respondent conditioning procedure with the use of Rescorla's truly-random control procedure. In the first experiment, pigeons received presentations of brief light on the response key and brief presentations of food where the light and the food were independently presented. All birds failed to key peck after many light and food presentations, but explicit pairing of the light and food rapidly conditioned pecking to the light. Experiment 2 showed that even when an independent light/food presentation schedule was reduced to variable-time 30 sec, additional naive birds would not key peck and only one bird pecked when the schedules were variable-time 15 sec. A third experiment examined an explicit-unpairing control procedure, where the light and food were not only presented on independent schedules but were also separated by a minimum time, and found that auto-shaping did not occur. A fourth experiment investigated a number of control procedures and found them ineffective. A fifth experiment investigated the effects of a physical separation of the locus of the response key and the food dispenser, and a sixth experiment investigated using a tone in place of the light. It was concluded that pecking is generated by auto-shaping procedures only when an intermittently presented keylight is regularly paired with food. PMID:16811710
Analysis of Air Traffic Track Data with the AutoBayes Synthesis System
NASA Technical Reports Server (NTRS)
Schumann, Johann Martin Philip; Cate, Karen; Lee, Alan G.
2010-01-01
The Next Generation Air Traffic System (NGATS) is aiming to provide substantial computer support for the air traffic controllers. Algorithms for the accurate prediction of aircraft movements are of central importance for such software systems but trajectory prediction has to work reliably in the presence of unknown parameters and uncertainties. We are using the AutoBayes program synthesis system to generate customized data analysis algorithms that process large sets of aircraft radar track data in order to estimate parameters and uncertainties. In this paper, we present, how the tasks of finding structure in track data, estimation of important parameters in climb trajectories, and the detection of continuous descent approaches can be accomplished with compact task-specific AutoBayes specifications. We present an overview of the AutoBayes architecture and describe, how its schema-based approach generates customized analysis algorithms, documented C/C++ code, and detailed mathematical derivations. Results of experiments with actual air traffic control data are discussed.
Faller, Josef; Scherer, Reinhold; Friedrich, Elisabeth V. C.; Costa, Ursula; Opisso, Eloy; Medina, Josep; Müller-Putz, Gernot R.
2014-01-01
Individuals with severe motor impairment can use event-related desynchronization (ERD) based BCIs as assistive technology. Auto-calibrating and adaptive ERD-based BCIs that users control with motor imagery tasks (“SMR-AdBCI”) have proven effective for healthy users. We aim to find an improved configuration of such an adaptive ERD-based BCI for individuals with severe motor impairment as a result of spinal cord injury (SCI) or stroke. We hypothesized that an adaptive ERD-based BCI, that automatically selects a user specific class-combination from motor-related and non motor-related mental tasks during initial auto-calibration (“Auto-AdBCI”) could allow for higher control performance than a conventional SMR-AdBCI. To answer this question we performed offline analyses on two sessions (21 data sets total) of cue-guided, five-class electroencephalography (EEG) data recorded from individuals with SCI or stroke. On data from the twelve individuals in Session 1, we first identified three bipolar derivations for the SMR-AdBCI. In a similar way, we determined three bipolar derivations and four mental tasks for the Auto-AdBCI. We then simulated both, the SMR-AdBCI and the Auto-AdBCI configuration on the unseen data from the nine participants in Session 2 and compared the results. On the unseen data of Session 2 from individuals with SCI or stroke, we found that automatically selecting a user specific class-combination from motor-related and non motor-related mental tasks during initial auto-calibration (Auto-AdBCI) significantly (p < 0.01) improved classification performance compared to an adaptive ERD-based BCI that only used motor imagery tasks (SMR-AdBCI; average accuracy of 75.7 vs. 66.3%). PMID:25368546
RETRACTED ARTICLE: Quorum-sensing of bacteria and its application
NASA Astrophysics Data System (ADS)
Jiang, Guoliang; Su, Mingxia
2009-12-01
Quorum sensing, or auto induction, as a cell density dependent signaling mechanism in many microorganisms, is triggered via auto inducers which passively diffuse across the bacterial envelope and therefore intracellulaly accumulate only at higher bacterial densities to regulate specialized processes such as genetic competence, bioluminescence, virulence and sporulation. N-acyl homoserine lactones are the most common type of signal molecules. Aquaculture is one of the fastest-growing food-producing industries, but disease outbreaks caused by pathogenic bacteria are a significant constraint on the development of the sector worldwide. Many of these pathogens have been found to be controlled by their quorum sensing systems. As there is relevance between the pathogenic bacteria's virulence factor expression and their auto inducers, quorum quenching is a new effective anti-infective strategy to control infections caused by bacterial pathogens in aquaculture. The techniques used to do this mainly include the following: (1) the inhibition of signal molecule biosynthesis, (2) blocking signal transduction, and (3) chemical inactivation and biodegradation of signal molecules. To provide a basis for finding alternative means of controlling aquatic diseases by quorum quenching instead of treatment by antibiotics and disinfectants, we will discuss the examination, purification and identification of auto inducers in this paper.
ERIC Educational Resources Information Center
Hevel, David; Tannehill, Dana, Ed.
This module is the eighth of nine modules in the competency-based Missouri Auto Mechanics Curriculum Guide. Six units cover: introduction to automatic transmission/transaxle; hydraulic control systems; transmission/transaxle diagnosis; automatic transmission/transaxle maintenance and adjustment; in-vehicle transmission repair; and off-car…
Anti-pentraxin 3 auto-antibodies might be protective in lupus nephritis: a large cohort study.
Yuan, Mo; Tan, Ying; Pang, Yun; Li, Yong-Zhe; Song, Yan; Yu, Feng; Zhao, Ming-Hui
2017-11-01
Anti-pentraxin 3 (PTX3) auto-antibodies were found to be associated with the absence of renal involvement in systemic lupus erythematosus (SLE). This study is to investigate the prevalence of anti-PTX3 auto-antibodies and their clinical significance based on a large Chinese lupus nephritis cohort. One hundred and ninety-six active lupus nephritis patients, 150 SLE patients without clinical renal involvement, and 100 healthy controls were enrolled. Serum anti-PTX3 auto-antibodies and PTX3 levels were screened by enzyme-linked immunosorbent assay (ELISA). The associations between anti-PTX3 auto-antibodies and clinicopathological parameters in lupus nephritis were further analyzed. Anti-PTX3 auto-antibodies were less prevalent in active lupus nephritis patients compared with SLE without renal involvement (19.4% (38/196) versus 40.7% (61/150), p < .001). The serum levels of anti-PTX3 auto-antibodies were negatively correlated with proteinuria in lupus nephritis (r = -.143, p = .047). The levels of proteinuria, serum creatinine, and the prevalence of thrombotic microangiopathy were significantly higher in patients with higher PTX3 levels (≥3.207 ng/ml) and without anti-PTX3 auto-antibodies compared with patients with lower PTX3 levels (<3.207 ng/ml) and with anti-PTX3 auto-antibodies (4.79 (3.39-8.28) versus 3.95 (1.78-7.0), p = .03; 168.84 ± 153.63 versus 101.44 ± 47.36, p = .01; 34.1% (14/41) versus 0% (0/9), p = .04; respectively). Anti-PTX3 auto-antibodies were less prevalent in active lupus nephritis patients compared with SLE without renal involvement and associated with less severe renal damage, especially with the combined evaluation of serum PTX3 levels.
A study experiment of auto idle application in the excavator engine performance
NASA Astrophysics Data System (ADS)
Purwanto, Wawan; Maksum, Hasan; Putra, Dwi Sudarno; Azmi, Meri; Wahyudi, Retno
2016-03-01
The purpose of this study was to analyze the effect of applying auto idle to excavator engine performance, such as machine unitization and fuel consumption in Excavator. Steps to be done are to modify the system JA 44 and 67 in Vehicle Electronic Control Unit (V-ECU). The modifications will be obtained from the pattern of the engine speed. If the excavator attachment is not operated, the engine speed will return to the idle speed automatically. From the experiment results the auto idle reduces fuel consumption in excavator engine.
A study experiment of auto idle application in the excavator engine performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Purwanto, Wawan, E-mail: wawan5527@gmail.com; Maksum, Hasan; Putra, Dwi Sudarno, E-mail: dwisudarnoputra@ft.unp.ac.id
2016-03-29
The purpose of this study was to analyze the effect of applying auto idle to excavator engine performance, such as machine unitization and fuel consumption in Excavator. Steps to be done are to modify the system JA 44 and 67 in Vehicle Electronic Control Unit (V-ECU). The modifications will be obtained from the pattern of the engine speed. If the excavator attachment is not operated, the engine speed will return to the idle speed automatically. From the experiment results the auto idle reduces fuel consumption in excavator engine.
ERIC Educational Resources Information Center
Mireles, S. Raymond
Self-Programmed Counseling, the instructor's guidance, and Self-Programmed Control (SPC), the student's response, was initially developed by Title III Project USTED (United Students and Teachers for Educational Development) for Mexican American college students on academic probation to use on a non-credit, special group counseling basis. As part…
}.caption-box{background:#000;background-color:rgba(0,0,0,.8);color:#fff;padding:1em}.caption-box .teaser }.carousel-caption .headline{color:#fff;font-size:16px;margin:0}@media (min-width:768px){.carousel-caption ;width:auto;height:auto}.carousel-controls{background-color:#000;line-height:1;margin-left:-15px;margin-right
The nucleosomal acidic patch relieves auto-inhibition by the ISWI remodeler SNF2h
Gamarra, Nathan; Johnson, Stephanie L; Trnka, Michael J; Burlingame, Alma L
2018-01-01
ISWI family chromatin remodeling motors use sophisticated autoinhibition mechanisms to control nucleosome sliding. Yet how the different autoinhibitory domains are regulated is not well understood. Here we show that an acidic patch formed by histones H2A and H2B of the nucleosome relieves the autoinhibition imposed by the AutoN and the NegC regions of the human ISWI remodeler SNF2h. Further, by single molecule FRET we show that the acidic patch helps control the distance travelled per translocation event. We propose a model in which the acidic patch activates SNF2h by providing a landing pad for the NegC and AutoN auto-inhibitory domains. Interestingly, the INO80 complex is also strongly dependent on the acidic patch for nucleosome sliding, indicating that this substrate feature can regulate remodeling enzymes with substantially different mechanisms. We therefore hypothesize that regulating access to the acidic patch of the nucleosome plays a key role in coordinating the activities of different remodelers in the cell. PMID:29664398
Mudrenko, I; Potapov, A; Sotnikov, D; Kolenko, O; Kmyta, A
2017-09-01
In this article the formation of psychopathological predictors auto-aggressive behavior in patients with a first psychotic episode were identified, which became "targets" in the framework of a comprehensive emergency suicide assistance to conduct the crisis psychotherapy. The work was done on the basis of the Sumy regional psychoneurologic dispensary, where 100 patients with a first psychotic episode were examined: 52 of them (core group) had suicidal symptoms and 48 (control group) had not. According to the test results of severity of auto-aggressive predictors (pre-suicidal syndrome) to clinicopsychopathological predictors of auto-aggressive behavior include: the narrowing of the cognitive function (p≤0,001), the avoidance of interpersonal contact (r≤0,001), the presence of affective (p≤0,001) and vegetative (p≤0,01) violations, the autoaggression of moderate severity (p≤0,001) and impulsivity (p≤0,001). Patients of the core group with the auto-aggressive behavior (n=58) completed a course of a crisis psychotherapy comprising the stages of crisis support, crisis intervention and increase the adaptation layer. After a psychotherapy course levels of aggression (6,45±0,41), auto-aggression (of 9,68±0,67), disorders in the affective sphere (18,58±0,66) and impulsivity (of 4,23±0,30) decreased, which was manifested in increasing tolerance to emotional stress factors, control over their emotions and reduce their affective valence (p≤0,001). The expansion of interpersonal interaction, the increase of patients social activity, the blood relationships establishment (of 9,23±0,40) was observed.
Immunological profiles in alopecia areata.
Galbraith, G M; Thiers, B H; Vasily, D B; Fudenberg, H H
1984-02-01
Cell-mediated immunity and auto-immune phenomena were investigated in sixty patients with active alopecia areata of various degrees of severity. Serum auto-antibodies to thyroid antigens were detected in twenty-three patients. Examination of T-lymphocyte populations, lymphocyte DNA synthesis, and lymphokine production in response to mitogen stimulation revealed no differences between the sixty patients and matched healthy control subjects. However, patients with thyroid auto-immunity and/or the presence of alopecia totalis or universalis showed significant reductions in interactive T lymphocytes (recognized by rosette formation with human B lymphoblastoid cells) and diminished production of leukocyte migration inhibition factor in response to stimulation with phytohaemagglutinin. This suggests that immune mechanisms may be involved in the pathogenesis of alopecia areata which is associated with thyroid auto-immunity or which progresses to total hair loss.
[Quantitative analysis of the corneal subbasal nerves in different degrees of dry eye with AutoCAD].
Cheng, Y; Wu, J; Zhu, H F; Cheng, Y; Zhu, X P
2016-03-01
To evaluate the practical value of AutoCAD in quantitative analysis of corneal subbasal epithelial nerves with different degrees of dry eye. Ninety patients were divided into groups of mild, moderate, and severe dry eye, 30 patients (60 eyes) in each group. And 30 healthy volunteers were recruited as the normal control group. Confocal microscopy was used to observe the length of the subbasal epithelial nerve plexus. The images were analyzed by AutoCAD software to determine the density (mm/mm(2)), the number of branches, and the curvature score of the subbasal epithelial nerves. These data of patients with dry eye and the controls were statistically compared, by analysis of variance(ANOV). By AutoCAD software, quantitative analysis of the corneal subbasal epithelial nerves was successfully performed. The nerve density in the patients with mild dry eye[(16.70±3.43) mm/mm(2)] was not significantly different from the controls[(15.87 ± 2.75) mm/mm(2)] (P=0.880), but the number of nerval branches 13.43±2.46 and the curvature 3.10±0.80 increased significantly (P<0.001). The nerve density in the patients with moderate and severe dry eye was significantly different from that in the normal control group (F=114.739, P<0.001). The neural density was significantly lower in the patients with severe dry eye than the controls, but there was no significant difference in the curvature scores between the two groups (P= 0.557). AutoCAD software is useful in the quantitative analysis of corneal nerve images under a confocal microscope. The corneal subbasal epithelial nerve density, the number of branches, and the curvature of the nerves are related to the degree of dry eye, and may be used as clinical indicators.
Open loop, auto reversing liquid nitrogen circulation thermal system for thermo vacuum chamber
NASA Astrophysics Data System (ADS)
Naidu, M. C. A.; Nolakha, Dinesh; Saharkar, B. S.; Kavani, K. M.; Patel, D. R.
2012-11-01
In a thermo vacuum chamber, attaining and controlling low and high temperatures (-100 Deg. C to +120 Deg. C) is a very important task. This paper describes the development of "Open loop, auto reversing liquid nitrogen based thermal system". System specifications, features, open loop auto reversing system, liquid nitrogen flow paths etc. are discussed in this paper. This thermal system consists of solenoid operated cryogenic valves, double embossed thermal plate (shroud), heating elements, temperature sensors and PLC. Bulky items like blowers, heating chambers, liquid nitrogen injection chambers, huge pipe lines and valves were not used. This entire thermal system is very simple to operate and PLC based, fully auto system with auto tuned to given set temperatures. This system requires a very nominal amount of liquid nitrogen (approx. 80 liters / hour) while conducting thermo vacuum tests. This system was integrated to 1.2m dia thermo vacuum chamber, as a part of its augmentation, to conduct extreme temperature cycling tests on passive antenna reflectors of satellites.
AC resistance measuring instrument
Hof, P.J.
1983-10-04
An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument. 8 figs.
AC Resistance measuring instrument
Hof, Peter J.
1983-01-01
An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument.
Lotfi, C F; Brentani, M M; Böhm, G M
1990-08-01
The mutagenic activity of the new Brazilian fuel, ethanol, was determined by employing the Salmonella typhimurium microsomal mutagenesis assay (TA97, TA98, TA100, TA102, and TA104) and a direct exposure method. This methodology was first used to determine the mutagenic activity of gasoline, revealing mutagenic activity of base-pair substitution without any need for metabolic activation, indicating the presence of direct-action mutagens. Experiments with ethanol suggest an indirect mutagenic activity of the oxidant type. The exposure system was considered suitable for future studies of gaseous mixtures.
[Auto-suture stapler EEA in surgery of the colon and rectum [author's transl)].
Thiede, A; Troidl, H; Poser, H; Jostarndt, L; Hamelmann, H
1980-01-01
The increasing use of auto-suture staplers for gastrointestinal anastomoses makes it necessary to test the value of this new method of suturing. In a "pilot study" the practicability, the tightness and permeability of the anastomosis and complications were tested and analysed in a total of 30 colon and rectal anastomoses using the EEA-suture gun. The results of 14 colon resections and 16 low anterior resections justify the further use of the EEA auto-suture apparatus and raise the question of a prospective controlled random study in which manual and mechanical machine sutured anastomoses are compared.
Randell, Edward W; Short, Garry; Lee, Natasha; Beresford, Allison; Spencer, Margaret; Kennell, Marina; Moores, Zoë; Parry, David
2018-06-01
Six Sigma involves a structured process improvement strategy that places processes on a pathway to continued improvement. The data presented here summarizes a project that took three clinical laboratories from autoverification processes that allowed between about 40% to 60% of tests being auto-verified to more than 90% of tests and samples auto-verified. The project schedule, metrics and targets, a description of the previous system and detailed information on the changes made to achieve greater than 90% auto-verification is presented for this Six Sigma DMAIC (Design, Measure, Analyze, Improve, Control) process improvement project.
Epperla, Narendranath; Fenske, Timothy S; Hari, Parameswaran N; Hamadani, Mehdi
2015-01-01
Lymphomas constitute the second most common indication for high dose therapy (HDT) followed by autologous hematopoietic cell transplantation (auto-HCT). The intent of administering HDT in these heterogeneous disorders varies from cure (e.g., in relapsed aggressive lymphomas) to disease control (e.g., most indolent lymphomas). Regardless of the underlying histology or remission status at transplantation, disease relapse remains the number one cause of post auto-HCT therapy failure and mortality. The last decade has seen a proliferation of clinical studies looking at prevention of post auto-HCT therapy failure with various maintenance strategies. The benefit of such therapies is in turn dependent on disease histology and timing of transplantation. In relapsed, chemosensitive diffuse large B-cell lymphoma (DLBCL), although post auto-HCT maintenance rituximab seems to be safe and feasible, it does not provide improved survival outcomes and is not recommended. The preliminary results with anti- programmed death -1 (PD-1) antibody therapy as post auto-HCT maintenance in DLBCL is promising but requires randomized validation. Similarly in follicular lymphoma, maintenance therapies including rituximab following auto-HCT should be considered investigational and offered only on a clinical trial. Rituximab maintenance results in improved progression-free survival but has not yet shown to improve overall survival in mantle cell lymphoma (MCL), but given the poor prognosis with post auto-HCT failure in MCL, maintenance rituximab can be considered on a case-by-case basis. Ongoing trials evaluating the efficacy of post auto-HCT maintenance with novel compounds (e.g., immunomodulators, PD-1 inhibitors, proteasome inhibitors and bruton’s tyrosine kinase inhibitors) will likely change the practice landscape in the near future for B cell non-Hodgkin lymphomas patients following HDT and auto-HCT. PMID:26421260
Pemmaraju, Naveen; Tanaka, Maria Florencia; Ravandi, Farhad; Lin, Heather; Baladandayuthapani, Veerabhadran; Rondon, Gabriela; Giralt, Sergio A.; Chen, Julianne; Pierce, Sherry; Cortes, Jorge; Kantarjian, Hagop; Champlin, Richard E.; De Lima, Marcos; Qazilbash, Muzaffar H.
2014-01-01
Outcomes in patients with acute promyelocytic leukemia have improved; however, a subset of patients relapse despite receiving all-trans-retinoic acid and/or arsenic-based therapies. Among 40 patients with acute promyelocytic leukemia who were treated at our institution (1980–2010), 24 received hematopoietic stem cell transplantation (HCT) (autologous HCT, 7; allogeneic HCT, 14; both, 3); 16 received chemotherapy only. All 3 strategies (autologous HCT, allogeneic HCT, chemotherapy) were feasible in patients with relapsed acute promyelocytic leukemia and result in long-term disease control in selected patients. Background Outcomes in patients with acute promyelocytic leukemia (APL) have improved; however, a significant number of patients still relapse despite receiving all-trans-retinoic acid (ATRA) and arsenic-based therapies. Patients and Methods Outcomes of patients with relapsed APL who were treated at our institution (1980–2010) and who received HCT were compared with those who received chemotherapy (CT) only. Results Among 40 patients, 24 received HCT (autologous [auto] HCT, 7; allogeneic [allo] HCT, 14; both, 3); 16 received CT only. The median age at diagnosis was 36 years (range, 13–50 years), 31 years (range, 16–58 years), and 44 years (range, 24–79 years) for the auto-HCT, allo-HCT, and CT groups, respectively. Ten (100%) patients who received auto-HCT and 12 (71%) who received allo-HCT were in complete remission at the time of the HCT. The median follow-ups in the auto-HCT, allo-HCT, and CT groups were 74 months (range, 26–135 months), 118 months (range, 28–284 months), and 122 months (range, 32–216 months), respectively. Transplantation-related mortality (1 year) after auto-HCT and allo-HCT were 10% and 29%, respectively. The 7-year event-free survival after auto-HCT and allo-HCT was 68.6% and 40.6%, respectively (P = .45). The 7-year overall survival was 85.7%, 49.4%, and 40% in the auto-HCT, allo-HCT, and CT groups, respectively (P = .48). Conclusion Both auto-HCT and allo-HCT are associated with durable remission and prolonged survival. All 3 strategies (auto-HCT, allo-HCT, CT) were found to be feasible in the relapsed APL setting and result in long-term disease control in selected patients. In this retrospective analysis, overall survival for patients who received HCT was not significantly better than patients who received CT only, but a trend toward better outcomes was seen in patients who underwent auto-HCT, although not statistically significant. PMID:23769669
Guler, Umut; Budak, Yasemin; Ruh, Emrah; Ocal, Yesim; Canay, Senay; Akyon, Yakut
2013-01-01
Objective: The aim of this study was 2-fold. The first aim was to evaluate the effects of mixing technique (hand-mixing or auto-mixing) on bacterial attachment to polyether impression materials. The second aim was to determine whether bacterial attachment to these materials was affected by length of exposure to disinfection solutions. Materials and Methods: Polyether impression material samples (n = 144) were prepared by hand-mixing or auto-mixing. Escherichia coli, Staphylococcus aureus and Pseudomonas aeruginosa were used in testing. After incubation, the bacterial colonies were counted and then disinfectant solution was applied. The effect of disinfection solution was evaluated just after the polymerization of impression material and 30 min after polymerization. Differences in adherence of bacteria to the samples prepared by hand-mixing and to those prepared by auto-mixing were assessed by Kruskal-Wallis and Mann-Whitney U-tests. For evaluating the efficiency of the disinfectant, Kruskal-Wallis multiple comparisons test was used. Results: E. coli counts were higher in hand-mixed materials (P < 0.05); no other statistically significant differences were found between hand- and auto-mixed materials. According to the Kruskal-Wallis test, significant differences were found between the disinfection procedures (Z > 2.394). Conclusion: The methods used for mixing polyether impression material did not affect bacterial attachment to impression surfaces. In contrast, the disinfection procedure greatly affects decontamination of the impression surface. PMID:24966729
Guler, Umut; Budak, Yasemin; Ruh, Emrah; Ocal, Yesim; Canay, Senay; Akyon, Yakut
2013-09-01
The aim of this study was 2-fold. The first aim was to evaluate the effects of mixing technique (hand-mixing or auto-mixing) on bacterial attachment to polyether impression materials. The second aim was to determine whether bacterial attachment to these materials was affected by length of exposure to disinfection solutions. Polyether impression material samples (n = 144) were prepared by hand-mixing or auto-mixing. Escherichia coli, Staphylococcus aureus and Pseudomonas aeruginosa were used in testing. After incubation, the bacterial colonies were counted and then disinfectant solution was applied. The effect of disinfection solution was evaluated just after the polymerization of impression material and 30 min after polymerization. Differences in adherence of bacteria to the samples prepared by hand-mixing and to those prepared by auto-mixing were assessed by Kruskal-Wallis and Mann-Whitney U-tests. For evaluating the efficiency of the disinfectant, Kruskal-Wallis multiple comparisons test was used. E. coli counts were higher in hand-mixed materials (P < 0.05); no other statistically significant differences were found between hand- and auto-mixed materials. According to the Kruskal-Wallis test, significant differences were found between the disinfection procedures (Z > 2.394). The methods used for mixing polyether impression material did not affect bacterial attachment to impression surfaces. In contrast, the disinfection procedure greatly affects decontamination of the impression surface.
Psychometric properties of the Autonomy over Tobacco Scale in German.
Wellman, R J; Di Franza, J R; Morgenstern, M; Hanewinkel, R; Isensee, B; Sabiston, C M
2012-01-01
We investigated the psychometric properties of a German translation of the 12-item Autonomy over Tobacco Scale (AUTOS) among 1,195 eighth-grade students. Data for this study were collected as part of the fourth wave of data collection of the Smokefree Class Competition intervention in the Saxony-Anhalt region of Germany. Students from the control arm of the Smokefree Class Competition study who indicated that they had ever smoked 'at least a few puffs' on a cigarette were classified as ever-smokers. They self-completed questionnaires distributed by teachers. AUTOS scores ranged from 0 to 36 with a distribution highly skewed toward lower-response categories. Inter-item correlations ranged from 0.65 to 0.89 (mean = 0.79, SD = 0.06). Composite reliability for the AUTOS was high (Ω = 0.96) and 3 lower-order factors were also reliable (withdrawal: 0.89, psychological dependence: 0.91, cue-induced cravings: 0.87). Concurrent validity was supported by strong relationships between the AUTOS and both lifetime cigarette consumption and current smoking frequency. Youths were 18 times more likely to be current smokers (95% CI = 11.9-27.2, p < 0.001) if they endorsed any AUTOS item. The German AUTOS is reliable and valid, and the results are consistent with the English AUTOS for use with adolescents. Copyright © 2011 S. Karger AG, Basel.
Zuo, Bin; Zhao, Yun-Xiao; Yang, Jian-Feng; He, Yang
2015-08-01
To investigate whether the plasma level of platelet auto- antibodies in ITP patients is related to that of co-stimulatory molecules sB7-H2 and sB7-H3. A total of 61 ITP patients and 25 healthy controls from the First Affiliated Hospital of Soochow University from June 2012 to August 2013 were enrolled in this study. The expression levels of platelet auto-antibodies against 5 glycoproteins (GPIX, GP Ib, GP IIIa, GPIIb and P-selectin) in plasma were detected by flow cytometric immuno-beads array, and the expression of soluable co-stimulatory molecules sB7-H2 and sB7-H3 was measured by ELISA. The plasma levels of 5 auto-antibodies against platelet membrance glycoproteins significantly increased in ITP patiens (P < 0.01). Compared with healthy controls, sB7-H2 levels increased (P < 0.05), while the sB7-H3 level did not significantly change (r = 0.13, P > 0.05). However, the correlation analysis showed that sB7-H3 negatively correlated with platelet P-selectin auto-antibody (r = -0.46, P < 0.05), and sB7-H2 and sB7-H3 significantly reduced in ITP patients with positive P-selectin auto-antibody (P < 0.01). In ITP patients, platelet counts negatively correlated with sB7-H2 (r = -0.3907, P < 0.01), but did not correlate with sB7-H3. Soluble costimulatory molecule sB7-H2 elevates in ITP patients, and the level of sB7-H3 is associated with auto-antibodies against P-selectin, suggesting that costimulatory molecules B7-H2 and B7-H3 may be involved in the pathogenesis of immune regulation abnormality in ITP.
Pockley, Alan Graham; Lindsay, James O.; Foulds, Gemma A.; Rutella, Sergio; Gribben, John G.; Alexander, Tobias; Snowden, John A.
2018-01-01
Patients with treatment refractory Crohn’s disease (CD) suffer debilitating symptoms, poor quality of life, and reduced work productivity. Surgery to resect inflamed and fibrotic intestine may mandate creation of a stoma and is often declined by patients. Such patients continue to be exposed to medical therapy that is ineffective, often expensive and still associated with a burden of adverse effects. Over the last two decades, autologous hematopoietic stem cell transplantation (auto-HSCT) has emerged as a promising treatment option for patients with severe autoimmune diseases (ADs). Mechanistic studies have provided proof of concept that auto-HSCT can restore immunological tolerance in chronic autoimmunity via the eradication of pathological immune responses and a profound reconfiguration of the immune system. Herein, we review current experience of auto-HSCT for the treatment of CD as well as approaches that have been used to monitor immune reconstitution following auto-HSCT in patients with ADs, including CD. We also detail immune reconstitution studies that have been integrated into the randomized controlled Autologous Stem cell Transplantation In refractory CD—Low Intensity Therapy Evaluation trial, which is designed to test the hypothesis that auto-HSCT using reduced intensity mobilization and conditioning regimens will be a safe and effective means of inducing sustained control in refractory CD compared to standard of care. Immunological profiling will generate insight into the pathogenesis of the disease, restoration of responsiveness to anti-TNF therapy in patients with recurrence of endoscopic disease and immunological events that precede the onset of disease in patients that relapse after auto-HSCT. PMID:29670622
Auto Code Generation for Simulink-Based Attitude Determination Control System
NASA Technical Reports Server (NTRS)
MolinaFraticelli, Jose Carlos
2012-01-01
This paper details the work done to auto generate C code from a Simulink-Based Attitude Determination Control System (ADCS) to be used in target platforms. NASA Marshall Engineers have developed an ADCS Simulink simulation to be used as a component for the flight software of a satellite. This generated code can be used for carrying out Hardware in the loop testing of components for a satellite in a convenient manner with easily tunable parameters. Due to the nature of the embedded hardware components such as microcontrollers, this simulation code cannot be used directly, as it is, on the target platform and must first be converted into C code; this process is known as auto code generation. In order to generate C code from this simulation; it must be modified to follow specific standards set in place by the auto code generation process. Some of these modifications include changing certain simulation models into their atomic representations which can bring new complications into the simulation. The execution order of these models can change based on these modifications. Great care must be taken in order to maintain a working simulation that can also be used for auto code generation. After modifying the ADCS simulation for the auto code generation process, it is shown that the difference between the output data of the former and that of the latter is between acceptable bounds. Thus, it can be said that the process is a success since all the output requirements are met. Based on these results, it can be argued that this generated C code can be effectively used by any desired platform as long as it follows the specific memory requirements established in the Simulink Model.
Johnson, J A; Fusaro, R M
1992-01-01
Since window glass absorbs sunlight below 320 nm, it provides a means of assessing sensitivity to longer wavelengths, i.e. UVA and visible radiation. Positive responses to the query of whether symptoms develop in the auto with the windows up must now be interpreted with regard to the possible presence of tinted plastic film on side and rear windows. These films block nearly all UVA radiation, as does the plastic interleaf of windshields. Thus, occupants of an auto equipped with plastic film receive photoprotection from UVB radiation and well into the UVA region. We define three classes of topical sunscreens: (1) conventional UVB screens, (2) broad-spectrum preparations containing a UVB screen and a UVA absorber and (3) browning agents such as dihydroxyacetone (DHA) that produce a skin coloration that absorbs in the low end of the visible region, with overlap into long-wavelength UVA. By considering responses of photosensitive persons in autos with tinted or untinted windows, coupled with efficacy of appropriate sunscreens, we produced an algorithm defining three photosensitivity subsets. Persons sensitive to long-wavelength UVA and/or visible radiation will benefit from tinted auto windows. In particular, patients with lupus erythematosus (LE) have actively promoted legislation allowing tinted windows. Support for their position is documented by recent reports of induction of lesions in LE patients by exposure to UVA and visible radiation. The brown color produced by DHA is a useful adjunct to the screening action of broad-spectrum sunscreens. Development of a durable color overnight allows application of the DHA preparation in the evening, thus eliminating possible interference with sunscreen use during the day.
NASA Astrophysics Data System (ADS)
Kim, Seonguk; Min, Kyoungdoug
2008-08-01
The CAI (controlled auto ignition) engine ignites fuel and air mixture by trapping high temperature burnt gas using a negative valve overlap. Due to auto ignition in CAI combustion, efficiency improvements and low level NOx emission can be obtained. Meanwhile, the CAI combustion regime is restricted and control parameters are limited. The start of combustion data in the compressed ignition engine are most critical for controlling the overall combustion. In this research, the engine block vibration signal is transformed by the Meyer wavelet to analyze CAI combustion more easily and accurately. Signal acquisition of the engine block vibration is a more suitable method for practical use than measurement of in-cylinder pressure. A new method for detecting combustion start in CAI engines through wavelet transformation of the engine block vibration signal was developed and results indicate that it is accurate enough to analyze the start of combustion. Experimental results show that wavelet transformation of engine block vibration can track the start of combustion in each cycle. From this newly developed method, the start of combustion data in CAI engines can be detected more easily and used as input data for controlling CAI combustion.
Brief report: Does exposure to violent video games increase moral disengagement among adolescents?
Gabbiadini, Alessandro; Andrighetto, Luca; Volpato, Chiara
2012-10-01
Several studies have repeatedly shown that violent/action video games increase aggressive tendencies. The present study provides preliminary evidence that exposure to these games also affects the process of moral disengagement. High school students (N = 385) were recruited, and the impact of both recency and frequency of their exposure to the video game Grand Theft Auto IV (GTA; 2008) on moral disengagement was explored. Results showed that exposure to GTA predicted higher levels of moral disengagement. Recency of exposure had a primary impact on the considered mechanisms of moral disengagement. These findings provide insights into a relevant detrimental effect of exposure to video games, to our knowledge not explored yet. Future research is needed to provide evidence of the causal link in the observed relationships. Copyright © 2012 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.
Small UAV Automatic Ground Collision Avoidance System Design Considerations and Flight Test Results
NASA Technical Reports Server (NTRS)
Sorokowski, Paul; Skoog, Mark; Burrows, Scott; Thomas, SaraKatie
2015-01-01
The National Aeronautics and Space Administration (NASA) Armstrong Flight Research Center Small Unmanned Aerial Vehicle (SUAV) Automatic Ground Collision Avoidance System (Auto GCAS) project demonstrated several important collision avoidance technologies. First, the SUAV Auto GCAS design included capabilities to take advantage of terrain avoidance maneuvers flying turns to either side as well as straight over terrain. Second, the design also included innovative digital elevation model (DEM) scanning methods. The combination of multi-trajectory options and new scanning methods demonstrated the ability to reduce the nuisance potential of the SUAV while maintaining robust terrain avoidance. Third, the Auto GCAS algorithms were hosted on the processor inside a smartphone, providing a lightweight hardware configuration for use in either the ground control station or on board the test aircraft. Finally, compression of DEM data for the entire Earth and successful hosting of that data on the smartphone was demonstrated. The SUAV Auto GCAS project demonstrated that together these methods and technologies have the potential to dramatically reduce the number of controlled flight into terrain mishaps across a wide range of aviation platforms with similar capabilities including UAVs, general aviation aircraft, helicopters, and model aircraft.
Self-optimization and auto-stabilization of receiver in DPSK transmission system.
Jang, Y S
2008-03-17
We propose a self-optimization and auto-stabilization method for a 1-bit DMZI in DPSK transmission. Using the characteristics of eye patterns, the optical frequency transmittance of a 1-bit DMZI is thermally controlled to maximize the power difference between the constructive and destructive output ports. Unlike other techniques, this control method can be realized without additional components, making it simple and cost effective. Experimental results show that error-free performance is maintained when the carrier optical frequency variation is approximately 10% of the data rate.
1997-11-24
2343 Calle Del Mundo Santa Clara, CA 95054-1008 Tel.: (408)727-8282 POC: J. A. Gotterba Durr Industries Environmental Systems Division 40600...1) LESS THAN 1 IV. FIRE AND EXPLOSION DATA FLASH POINT (TEST METHOD) ABOVE 200*P AUTO IGNITION ABOVE TEMPERATURE iJfJO’P...IST METHOD, ?oo.._r T,CCT CxriNOUISHINO Mt 01A WATER AUTO IGNITION ABOVB I rLAM**BLt »•’•’"’• TEMPERATURE ^QQly | IN AIR
AutoCPAP initiation at home: optimal trial duration and cost-effectiveness.
Bachour, Adel; Virkkala, Jussi T; Maasilta, Paula K
2007-11-01
The duration of automatic computer-controlled continuous positive airway pressure device (autoCPAP) initiation at home varies largely between sleep centers. Our objectives were to evaluate the cost-effectiveness and to find the optimal trial duration. Of the 206 consecutive CPAP-naive patients with obstructive sleep apnea syndrome, who were referred to our hospital, 166 received autoCPAP for a 5-day trial at home. Of the 166 patients, 89 (15 women) showed a successful 5-day autoCPAP trial (normalized oximetry and mask-on time exceeding 4 h/day for at least 4 days). For the first trial day, 88 (53%) patients had normalized oximetry and a mask-on time exceeding 4 h. A 1-day autoCPAP trial EUR 668 was less cost-effective than a 5-day trial EUR 653, with no differences in values of efficient CPAP pressure or residual apnea-hypopnea index (AHI). The systematic requirement of oximetry monitoring raised the cost considerably from EUR 481 to EUR 668. In selected patients with obstructive sleep apnea, the optimal duration for initiating CPAP therapy at home by autoCPAP is 5 days. Although a 1-day trial was sufficient to determine the CPAP pressure requirement, it was not cost-effective and had a high rate of failure.
Baigorri, F; de Monte, A; Blanch, L; Fernández, R; Vallés, J; Mestre, J; Saura, P; Artigas, A
1994-11-01
To study the effect of positive end-expiratory pressure (PEEP) on right ventricular hemodynamics and ejection fraction in patients with chronic obstructive pulmonary disease and positive alveolar pressure throughout expiration by dynamic hyperinflation (auto-PEEP). Open, prospective, controlled trial. General intensive care unit of a community hospital. Ten patients sedated and paralyzed with an acute exacerbation of chronic obstructive pulmonary disease undergoing mechanical ventilation. Insertion of a pulmonary artery catheter modified with a rapid response thermistor and a radial arterial catheter. PEEP was then increased from 0 (PEEP 0) to auto-PEEP level (PEEP = auto-PEEP) and 5 cm H2O above that (PEEP = auto-PEEP +5). At each level of PEEP, airway pressures, flow and volume, hemodynamic variables (including right ventricular ejection fraction by thermodilution technique), and blood gas analyses were recorded. The mean auto-PEEP was 6.6 +/- 2.8 cm H2O and the total PEEP reached was 12.2 +/- 2.4 cm H2O. The degree of lung inflation induced by PEEP averaged 145 +/- 87 mL with PEEP = auto-PEEP and 495 +/- 133 mL with PEEP = auto-PEEP + 5. The PEEP = auto-PEEP caused a right ventricular end-diastolic pressure increase, but there was no other significant hemodynamic change. With PEEP = auto-PEEP + 5, there was a significant increase in intravascular pressures; this amount of PEEP reduced cardiac output (from 4.40 +/- 1.38 L/min at PEEP 0 to 4.13 +/- 1.48 L/min; p < .05). The cardiac output reduction induced by PEEP = auto-PEEP + 5 was > 10% in only five cases and this group of patients had significantly lower right ventricular volumes than the group with less cardiac output variation (right ventricular end-diastolic volume: 64 +/- 9 vs. 96 +/- 26 mL/m2; right ventricular end-systolic volume: 38 +/- 6 vs. 65 +/- 21 mL/m2; p < .05) without significant difference in the other variables that were measured. Neither right ventricular ejection fraction nor right ventricle volumes changed as PEEP increased, but there were marked interpatient differences and also pronounced changes in volume between stages in individual patients. In the study conditions, PEEP application up to values approaching auto-PEEP did not result in the impairment of right ventricular hemodynamics, while higher levels reduced cardiac output in selected patients.
Vlachakis, Georgios; Chatterjee, Sayantani; Arroyo-Mateos, Manuel; Wackers, Paul F. K.; Jonker, Martijs J.
2018-01-01
Increased ambient temperature is inhibitory to plant immunity including auto-immunity. SNC1-dependent auto-immunity is, for example, fully suppressed at 28°C. We found that the Arabidopsis sumoylation mutant siz1 displays SNC1-dependent auto-immunity at 22°C but also at 28°C, which was EDS1 dependent at both temperatures. This siz1 auto-immune phenotype provided enhanced resistance to Pseudomonas at both temperatures. Moreover, the rosette size of siz1 recovered only weakly at 28°C, while this temperature fully rescues the growth defects of other SNC1-dependent auto-immune mutants. This thermo-insensitivity of siz1 correlated with a compromised thermosensory growth response, which was independent of the immune regulators PAD4 or SNC1. Our data reveal that this high temperature induced growth response strongly depends on COP1, while SIZ1 controls the amplitude of this growth response. This latter notion is supported by transcriptomics data, i.e. SIZ1 controls the amplitude and timing of high temperature transcriptional changes including a subset of the PIF4/BZR1 gene targets. Combined our data signify that SIZ1 suppresses an SNC1-dependent resistance response at both normal and high temperatures. At the same time, SIZ1 amplifies the dark and high temperature growth response, likely via COP1 and upstream of gene regulation by PIF4 and BRZ1. PMID:29357355
Computer-Controlled System for Plasma Ion Energy Auto-Analyzer
NASA Astrophysics Data System (ADS)
Wu, Xian-qiu; Chen, Jun-fang; Jiang, Zhen-mei; Zhong, Qing-hua; Xiong, Yu-ying; Wu, Kai-hua
2003-02-01
A computer-controlled system for plasma ion energy auto-analyzer was technically studied for rapid and online measurement of plasma ion energy distribution. The system intelligently controls all the equipments via a RS-232 port, a printer port and a home-built circuit. The software designed by Lab VIEW G language automatically fulfils all of the tasks such as system initializing, adjustment of scanning-voltage, measurement of weak-current, data processing, graphic export, etc. By using the system, a few minutes are taken to acquire the whole ion energy distribution, which rapidly provides important parameters of plasma process techniques based on semiconductor devices and microelectronics.
NASA Technical Reports Server (NTRS)
Postma, Barry Dirk
2005-01-01
This thesis discusses application of a robust constrained optimization approach to control design to develop an Auto Balancing Controller (ABC) for a centrifuge rotor to be implemented on the International Space Station. The design goal is to minimize a performance objective of the system, while guaranteeing stability and proper performance for a range of uncertain plants. The Performance objective is to minimize the translational response of the centrifuge rotor due to a fixed worst-case rotor imbalance. The robustness constraints are posed with respect to parametric uncertainty in the plant. The proposed approach to control design allows for both of these objectives to be handled within the framework of constrained optimization. The resulting controller achieves acceptable performance and robustness characteristics.
Wu, Yang; Li, Jinquan; Yan, Biao; Zhu, Yuqing; Liu, Xudong; Chen, Mingqing; Li, Dai; Lee, Ching-Chang; Yang, Xu; Ma, Ping
2017-11-13
Chronic lymphocytic thyroiditis (CLT) is a common autoimmune disorder. The possible pathogenic role and mechanism of dibutyl phthalate (DBP) in CLT is still controversial. Experiments were conducted after 35-days of oral exposure to the three concentrations of DBP or saline, and three immunizations with thyroglobulin (TG). Healthy female Wistar rats were randomly divided into ten exposure groups (n = 8 each): (A) saline control, (B) 0.5 mg/kg/d DBP, (C) 5 mg/kg/d DBP, (D) 50 mg/kg/d DBP, (E) TG-immunized group, (F) TG- combined with 0.5 mg/kg/d DBP, (G) TG- combined with 5 mg/kg/d DBP, (H) TG- combined with 50 mg/kg/d DBP, (I) TG- combined with 50 mg/kg/d DBP plus 100 mg/kg/d vitamin C; (J) 100 mg/kg/d vitamin C. We showed that oral exposure DBP can aggravate CLT in rats. This deterioration was concomitant with increased thyroid auto antibodies, Th1/Th2 imbalance and Th17 immune response, activated pro-inflammatory and apoptosis pathways, and increased thyroid dysfunction in rats. Our results also suggested that DBP could promote oxidative damage. The study also found that vitamin C reduced the levels of oxidative stress and alleviated CLT. In short, the study showed that DBP exacerbated CLT through oxidative stress.
Irving, W L; James, D K; Stephenson, T; Laing, P; Jameson, C; Oxford, J S; Chakraverty, P; Brown, D W; Boon, A C; Zambon, M C
2000-10-01
To determine whether maternal influenza virus infection in the second and third trimesters of pregnancy results in transplacental transmission of infection, maternal auto-antibody production or an increase in complications of pregnancy. Case-control cohort study. Study and control cohorts were derived from 3,975 women who were consecutively delivered at two Nottingham teaching hospitals between May 1993 and July 1994. A complete set of three sera was available for 1,659 women. Paired maternal ante- and postnatal sera were screened for a rise in anti-influenza virus antibody titre by single radial haemolysis and haemagglutination inhibition. Routine obstetric data collected during and after pregnancy were retrieved from the Nottingham obstetric database. Cord samples were tested for the presence of IgM anti-influenza antibodies, and postnatal infant sera were tested for the persistence of influenza-virus specific IgG. Paired antenatal and postnatal sera were tested against a standard range of auto-antigens by immunofluorescence. Classification of women as having definite serological evidence of an influenza virus infection in pregnancy (cases) or as controls. Intercurrent influenza virus infections were identified in 182/1,659 (11.0%) pregnancies. None of 138 cord sera from maternal influenza cases was positive for influenza A virus specific IgM. IgG anti-influenza antibodies did not persist in any of 12 infant sera taken at age 6-12 months. Six of 172 postnatal maternal sera from cases of influenza were positive for auto-antibodies. In all cases the corresponding antenatal serum was also positive for the same auto-antibody. There were no significant differences in pregnancy outcome measures between cases and controls. Overall, there were significantly more complications of pregnancy in the cases versus the controls, but no single type of complication achieved statistical significance. Influenza infection in the second and third trimesters of pregnancy is a relatively common event. We found no evidence for transplacental transmission of influenza virus or auto-antibody production in pregnancies complicated by influenza infections. There was an increase in the complications of pregnancy in our influenza cohort.
High density growth of T7 expression strains with auto-induction option
Studier, F. William
2013-03-19
A method for promoting and suppressing auto-induction of transcription of a cloned gene 1 of bacteriophage T7 in cultures of bacterial cells grown batchwise is disclosed. The transcription is under the control of a promoter whose activity can be induced by an exogenous inducer whose ability to induce said promoter is dependent on the metabolic state of said bacterial cells.
Ejaz, Sohail; Ejaz, Ahmed; Sohail, Amara; Ahmed, Mukthar; Nasir, Amar; Lim, Chae Woong
2009-07-01
In south Asian countries, a campaign has launched to promote CNG-powered four-stroke auto-rickshaws (CNFAR) to decrease emission load in the environment. Even though, CNFAR are considered environmentally safe, emissions of some other toxic chemicals would amplify, which may effect the development of growing fetus and may result in different growth defects. By utilizing the in vivo chicken embryo model, this report analyzes the toxic potential of CNFAR smoke solutions (CNFARSS) on embryonic movements (EM) and cardiovascular development. Application of CNFARSS to embryos caused profound decline (p<0.001) in all four types of EMs. Several recovery attempts of all EMs were observed in oscillating fashion, however, EMs did not recover by the end of experiment. Exposure of CNFARSS escorted intense decline (p<0.001) with temperate recovery phases in the EM of tail. Macroscopic evaluation of all CNFARSS treated chicken embryos revealed several widespread hemorrhaging throughout the whole body. Moreover, four different types of ectopia cordis were prominently observed among all CNFARSS treated embryos, namely; incomplete ectopia cordis, complete ectopia cordis, cervico-thoracic ectopia cordis and thoraco-abdominal ectopia cordis.
Faisal, Mohammad; Shahab, Uzma; Alatar, Abdulrahman A; Ahmad, Saheem
2017-11-01
The structural perturbations in DNA molecule may be caused by a break in a strand, a missing base from the backbone, or a chemically changed base. These alterations in DNA that occurs naturally can result from metabolic or hydrolytic processes. DNA damage plays a major role in the mutagenesis, carcinogenesis, aging and various other patho-physiological conditions. DNA damage can be induced through hydrolysis, exposure to reactive oxygen species (ROS) and other reactive carbonyl metabolites including 4-hydroxynonenal (HNE). 4-HNE is an important lipid peroxidation product which has been implicated in the mutagenesis and carcinogenesis processes. The present study examines to probe the presence of auto-antibodies against 4-hydroxynonenal damaged DNA (HNE-DNA) in various cancer subjects. In this study, the purified calf thymus DNA was damaged by the action of 4-HNE. The DNA was incubated with 4-HNE for 24 h at 37°C temperature. The binding characteristics of cancer auto-antibodies were assessed by direct binding and competitive inhibition ELISA. DNA modifications produced hyperchromicity in UV spectrum and decreased fluorescence intensity. Cancer sera exhibited enhanced binding with the 4-HNE modified calf thymus DNA as compared to its native conformer. The 4-HNE modified DNA presents unique epitopes which may be one of the factors for the auto-antibody induction in cancer patients. The HNE modified DNA presents unique epitopes which may be one of the factors for the autoantibody induction in cancer patients. © 2017 Wiley Periodicals, Inc.
Effect of light aging on silicone-resin bond strength in maxillofacial prostheses.
Polyzois, Gregory; Pantopoulos, Antonis; Papadopoulos, Triantafillos; Hatamleh, Muhanad
2015-04-01
The aim of this study was to investigate the effect of accelerated light aging on bond strength of a silicone elastomer to three types of denture resin. A total of 60 single lap joint specimens were fabricated with auto-, heat-, and photopolymerized (n = 20) resins. An addition-type silicone elastomer (Episil-E) was bonded to resins treated with the same primer (A330-G). Thirty specimens served as controls and were tested after 24 hours, and the remaining were aged under accelerated exposure to daylight for 546 hours (irradiance 765 W/m(2) ). Lap shear joint tests were performed to evaluate bond strength at 50 mm/min crosshead speed. Two-way ANOVA and Tukey's test were carried out to detect statistical significance (p < 0.05). ANOVA showed that the main effect of light aging was the most important factor determining the shear bond strength. The mean bond strength values ranged from 0.096 to 0.136 MPa. The highest values were recorded for auto- (0.131 MPa) and photopolymerized (0.136 MPa) resins after aging. Accelerated light aging for 546 hours affects the bond strength of an addition-type silicone elastomer to three different denture resins. The bond strength significantly increased after aging for photo- and autopolymerized resins. All the bonds failed adhesively. © 2014 by the American College of Prosthodontists.
Zhang, BiTao; Pi, YouGuo; Luo, Ying
2012-09-01
A fractional order sliding mode control (FROSMC) scheme based on parameters auto-tuning for the velocity control of permanent magnet synchronous motor (PMSM) is proposed in this paper. The control law of the proposed F(R)OSMC scheme is designed according to Lyapunov stability theorem. Based on the property of transferring energy with adjustable type in F(R)OSMC, this paper analyzes the chattering phenomenon in classic sliding mode control (SMC) is attenuated with F(R)OSMC system. A fuzzy logic inference scheme (FLIS) is utilized to obtain the gain of switching control. Simulations and experiments demonstrate that the proposed FROSMC not only achieve better control performance with smaller chatting than that with integer order sliding mode control, but also is robust to external load disturbance and parameter variations. Copyright © 2012 ISA. Published by Elsevier Ltd. All rights reserved.
Empiric Auto-Titrating CPAP in People with Suspected Obstructive Sleep Apnea
Drummond, Fitzgerald; Doelken, Peter; Ahmed, Qanta A.; Gilbert, Gregory E.; Strange, Charlie; Herpel, Laura; Frye, Michael D.
2010-01-01
Objective: Efficient diagnosis and treatment of obstructive sleep apnea (OSA) can be difficult because of time delays imposed by clinic visits and serial overnight polysomnography. In some cases, it may be desirable to initiate treatment for suspected OSA prior to polysomnography. Our objective was to compare the improvement of daytime sleepiness and sleep-related quality of life of patients with high clinical likelihood of having OSA who were randomly assigned to receive empiric auto-titrating continuous positive airway pressure (CPAP) while awaiting polysomnogram versus current usual care. Methods: Serial patients referred for overnight polysomnography who had high clinical likelihood of having OSA were randomly assigned to usual care or immediate initiation of auto-titrating CPAP. Epworth Sleepiness Scale (ESS) scores and the Functional Outcomes of Sleep Questionnaire (FOSQ) scores were obtained at baseline, 1 month after randomization, and again after initiation of fixed CPAP in control subjects and after the sleep study in auto-CPAP patients. Results: One hundred nine patients were randomized. Baseline demographics, daytime sleepiness, and sleep-related quality of life scores were similar between groups. One-month ESS and FOSQ scores were improved in the group empirically treated with auto-titrating CPAP. ESS scores improved in the first month by a mean of −3.2 (confidence interval −1.6 to −4.8, p < 0.001) and FOSQ scores improved by a mean of 1.5, (confidence interval 0.5 to 2.7, p = 0.02), whereas scores in the usual-care group did not change (p = NS). Following therapy directed by overnight polysomnography in the control group, there were no differences in ESS or FOSQ between the groups. No adverse events were observed. Conclusion: Empiric auto-CPAP resulted in symptomatic improvement of daytime sleepiness and sleep-related quality of life in a cohort of patients awaiting polysomnography who had a high pretest probability of having OSA. Additional studies are needed to evaluate the applicability of empiric treatment to other populations. Citation: Drummond F; Doelken P; Ahmed QA; Gilbert GE; Strange C; Herpel L; Frye MD. Empiric auto-titrating CPAP in people with suspected obstructive sleep apnea. J Clin Sleep Med 2010;6(2):140-145. PMID:20411690
Can we still dream when the mind is blank? Sleep and dream mentations in auto-activation deficit.
Leu-Semenescu, Smaranda; Uguccioni, Ginevra; Golmard, Jean-Louis; Czernecki, Virginie; Yelnik, Jerome; Dubois, Bruno; Forgeot d'Arc, Baudouin; Grabli, David; Levy, Richard; Arnulf, Isabelle
2013-10-01
Bilateral damage to the basal ganglia causes auto-activation deficit, a neuropsychological syndrome characterized by striking apathy, with a loss of self-driven behaviour that is partially reversible with external stimulation. Some patients with auto-activation deficit also experience a mental emptiness, which is defined as an absence of any self-reported thoughts. We asked whether this deficit in spontaneous activation of mental processing may be reversed during REM sleep, when dreaming activity is potentially elicited by bottom-up brainstem stimulation on the cortex. Sleep and video monitoring over two nights and cognitive tests were performed on 13 patients with auto-activation deficit secondary to bilateral striato-pallidal lesions and 13 healthy subjects. Dream mentations were collected from home diaries and after forced awakenings in non-REM and REM sleep. The home diaries were blindly analysed for length, complexity and bizarreness. A mental blank during wakefulness was complete in six patients and partial in one patient. Four (31%) patients with auto-activation deficit (versus 92% of control subjects) reported mentations when awakened from REM sleep, even when they demonstrated a mental blank during the daytime (n = 2). However, the patients' dream reports were infrequent, short, devoid of any bizarre or emotional elements and tended to be less complex than the dream mentations of control subjects. The sleep duration, continuity and stages were similar between the groups, except for a striking absence of sleep spindles in 6 of 13 patients with auto-activation deficit, despite an intact thalamus. The presence of spontaneous dreams in REM sleep in the absence of thoughts during wakefulness in patients with auto-activation deficit supports the idea that simple dream imagery is generated by brainstem stimulation and is sent to the sensory cortex. However, the lack of complexity in these dream mentations suggests that the full dreaming process (scenario, emotions, etc.) require these sensations to be interpreted by higher-order cortical areas. The absence of sleep spindles in localized lesions in the basal ganglia highlights the role of the pallidum and striatum in spindling activity during non-REM sleep.
AutoDrug: fully automated macromolecular crystallography workflows for fragment-based drug discovery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsai, Yingssu; Stanford University, 333 Campus Drive, Mudd Building, Stanford, CA 94305-5080; McPhillips, Scott E.
New software has been developed for automating the experimental and data-processing stages of fragment-based drug discovery at a macromolecular crystallography beamline. A new workflow-automation framework orchestrates beamline-control and data-analysis software while organizing results from multiple samples. AutoDrug is software based upon the scientific workflow paradigm that integrates the Stanford Synchrotron Radiation Lightsource macromolecular crystallography beamlines and third-party processing software to automate the crystallography steps of the fragment-based drug-discovery process. AutoDrug screens a cassette of fragment-soaked crystals, selects crystals for data collection based on screening results and user-specified criteria and determines optimal data-collection strategies. It then collects and processes diffraction data,more » performs molecular replacement using provided models and detects electron density that is likely to arise from bound fragments. All processes are fully automated, i.e. are performed without user interaction or supervision. Samples can be screened in groups corresponding to particular proteins, crystal forms and/or soaking conditions. A single AutoDrug run is only limited by the capacity of the sample-storage dewar at the beamline: currently 288 samples. AutoDrug was developed in conjunction with RestFlow, a new scientific workflow-automation framework. RestFlow simplifies the design of AutoDrug by managing the flow of data and the organization of results and by orchestrating the execution of computational pipeline steps. It also simplifies the execution and interaction of third-party programs and the beamline-control system. Modeling AutoDrug as a scientific workflow enables multiple variants that meet the requirements of different user groups to be developed and supported. A workflow tailored to mimic the crystallography stages comprising the drug-discovery pipeline of CoCrystal Discovery Inc. has been deployed and successfully demonstrated. This workflow was run once on the same 96 samples that the group had examined manually and the workflow cycled successfully through all of the samples, collected data from the same samples that were selected manually and located the same peaks of unmodeled density in the resulting difference Fourier maps.« less
Use of Semi-Autonomous Tools for ISS Commanding and Monitoring
NASA Technical Reports Server (NTRS)
Brzezinski, Amy S.
2014-01-01
As the International Space Station (ISS) has moved into a utilization phase, operations have shifted to become more ground-based with fewer mission control personnel monitoring and commanding multiple ISS systems. This shift to fewer people monitoring more systems has prompted use of semi-autonomous console tools in the ISS Mission Control Center (MCC) to help flight controllers command and monitor the ISS. These console tools perform routine operational procedures while keeping the human operator "in the loop" to monitor and intervene when off-nominal events arise. Two such tools, the Pre-positioned Load (PPL) Loader and Automatic Operators Recorder Manager (AutoORM), are used by the ISS Communications RF Onboard Networks Utilization Specialist (CRONUS) flight control position. CRONUS is responsible for simultaneously commanding and monitoring the ISS Command & Data Handling (C&DH) and Communications and Tracking (C&T) systems. PPL Loader is used to uplink small pieces of frequently changed software data tables, called PPLs, to ISS computers to support different ISS operations. In order to uplink a PPL, a data load command must be built that contains multiple user-input fields. Next, a multiple step commanding and verification procedure must be performed to enable an onboard computer for software uplink, uplink the PPL, verify the PPL has incorporated correctly, and disable the computer for software uplink. PPL Loader provides different levels of automation in both building and uplinking these commands. In its manual mode, PPL Loader automatically builds the PPL data load commands but allows the flight controller to verify and save the commands for future uplink. In its auto mode, PPL Loader automatically builds the PPL data load commands for flight controller verification, but automatically performs the PPL uplink procedure by sending commands and performing verification checks while notifying CRONUS of procedure step completion. If an off-nominal condition occurs during procedure execution, PPL Loader notifies CRONUS through popup messages, allowing CRONUS to examine the situation and choose an option of how PPL loader should proceed with the procedure. The use of PPL Loader to perform frequent, routine PPL uplinks offloads CRONUS to better monitor two ISS systems. It also reduces procedure performance time and decreases risk of command errors. AutoORM identifies ISS communication outage periods and builds commands to lock, playback, and unlock ISS Operations Recorder files. Operation Recorder files are circular buffer files of continually recorded ISS telemetry data. Sections of these files can be locked from further writing, be played back to capture telemetry data that occurred during an ISS loss of signal (LOS) period, and then be unlocked for future recording use. Downlinked Operation Recorder files are used by mission support teams for data analysis, especially if failures occur during LOS. The commands to lock, playback, and unlock Operations Recorder files are encompassed in three different operational procedures and contain multiple user-input fields. AutoORM provides different levels of automation for building and uplinking the commands to lock, playback, and unlock Operations Recorder files. In its automatic mode, AutoORM automatically detects ISS LOS periods, then generates and uplinks the commands to lock, playback, and unlock Operations Recorder files when MCC regains signal with ISS. AutoORM also features semi-autonomous and manual modes which integrate CRONUS more into the command verification and uplink process. AutoORMs ability to automatically detect ISS LOS periods and build the necessary commands to preserve, playback, and release recorded telemetry data greatly offloads CRONUS to perform more high-level cognitive tasks, such as mission planning and anomaly troubleshooting. Additionally, since Operations Recorder commands contain numerical time input fields which are tedious for a human to manually build, AutoORM's ability to automatically build commands reduces operational command errors. PPL Loader and AutoORM demonstrate principles of semi-autonomous operational tools that will benefit future space mission operations. Both tools employ different levels of automation to perform simple and routine procedures, thereby offloading human operators to perform higher-level cognitive tasks. Because both tools provide procedure execution status and highlight off-nominal indications, the flight controller is able to intervene during procedure execution if needed. Semi-autonomous tools and systems that can perform routine procedures, yet keep human operators informed of execution, will be essential in future long-duration missions where the onboard crew will be solely responsible for spacecraft monitoring and control.
Toward reliable and repeatable automated STEM-EDS metrology with high throughput
NASA Astrophysics Data System (ADS)
Zhong, Zhenxin; Donald, Jason; Dutrow, Gavin; Roller, Justin; Ugurlu, Ozan; Verheijen, Martin; Bidiuk, Oleksii
2018-03-01
New materials and designs in complex 3D architectures in logic and memory devices have raised complexity in S/TEM metrology. In this paper, we report about a newly developed, automated, scanning transmission electron microscopy (STEM) based, energy dispersive X-ray spectroscopy (STEM-EDS) metrology method that addresses these challenges. Different methodologies toward repeatable and efficient, automated STEM-EDS metrology with high throughput are presented: we introduce the best known auto-EDS acquisition and quantification methods for robust and reliable metrology and present how electron exposure dose impacts the EDS metrology reproducibility, either due to poor signalto-noise ratio (SNR) at low dose or due to sample modifications at high dose conditions. Finally, we discuss the limitations of the STEM-EDS metrology technique and propose strategies to optimize the process both in terms of throughput and metrology reliability.
An auto-bias control scheme for IQ-modulator with various modulation formats
NASA Astrophysics Data System (ADS)
Zhang, Wenqi; Yuan, Xueguang; Zhang, Yang'an
2016-10-01
We propose and demonstrate an auto-bias control scheme for the IQ-modulator of a flexible optical PSK or QAM or other modulation formats transmitter in this paper. Due to IQ-modulators usually producing higher-order modulation format, these modulation formats involve phase mostly. It is based on that the bias drift will change the operating point and result in varying the output optical phase. This technology has no restrictions on modulation formats, so it has good flexibility. The experimental result show the three biases can be stabilized when the proposed scheme is implemented.
Ristow, O; Otto, S; Geiß, C; Kehl, V; Berger, M; Troeltzsch, M; Koerdt, S; Hohlweg-Majert, B; Freudlsperger, C; Pautke, C
2017-02-01
Recent studies have indicated that bone shows auto-fluorescence under an appropriate fluorescence lamp. The aim of this preliminary study was to compare the success rates of the established tetracycline fluorescence-guided bone surgery with auto-fluorescence-guided bone surgery in the treatment of medication-related osteonecrosis of the jaw (MRONJ). Forty patients suffering from MRONJ were referred for surgical treatment and were divided randomly into two groups: auto-fluorescence (n=20) or tetracycline fluorescence (n=20) guided bone surgery. The primary endpoint was treatment success, defined as the absence of exposed bone at 8 weeks after surgery. Secondary outcomes assessed were mucosal integrity, signs of infection, pain, and loss of sensitivity; these were evaluated descriptively at 10 days, 8 weeks, 6 months, and 1 year after surgery. At 8 weeks postoperative, 18/20 patients (90%) in the auto-fluorescence group and 17/20 patients (85%) in the tetracycline fluorescence group showed mucosal integrity (P>0.05). At the last follow-up, 94% in the auto-fluorescence group and 89% in the tetracycline fluorescence group presented complete mucosal coverage with no exposed bone, infection, or pain (P>0.05). There was no significant difference between the two techniques for any of the secondary outcomes (P>0.05). The results of this preliminary study show that auto-fluorescence-guided bone surgery has comparable success rates to the established tetracycline fluorescence-guided bone surgery. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Akintunde, J K; Oboh, G
2015-11-01
One of the major hazards arising from recycling sites is the generation of leachate containing mixed metal. This study evaluated the toxic effects of leachate obtained from Elewi Odo municipal auto-battery recycling site (EOMABRSL) on male liver functions using hepatic indices and biomarker of cellular adenosine triphosphate (ATP) in rat via the oral route. Concentrations of heavy metals analysis showed that lead, cadmium, nickel, chromium, manganese, and iron were 1.5-, 2-, 2.5-, 1.36-, 19.61-, and 8.89-folds, respectively, higher than acceptable limits set by regulatory authority World Health Organization. Copper, zinc, and cobalt were 5.9-, 300-, and 1.02-folds, respectively, lower than permissible limits. The EOMABRSL was administered at 20, 40, 60, 80, and 100% concentrations to adult male rats for 60 days. Following exposure, plasma and livers were collected for several biochemistry assays. Exposure of animals to EOMABRSL resulted in 27.51, 28.14, 63.93, 28.42, and 40.16% increase in aspartate aminotransferase activity, whereas it elevated alanine aminotransferase activity by 5.35, 22.33, 88.68, 183.02, and 193.08%, respectively, when compared with the control. Similarly, γ-glutamyl transferase activity increased by 111.22, 114.19, 122.96, 573.14, and 437.02%, respectively, when compared with the control. EOMABRSL administration significantly decreased catalase activity and reduced glutathione level and superoxide dismutase with concomitant increase in malondialdehyde and hydrogen peroxide levels. Also, significant (p < 0.05) decrease in lactate dehydrogenase (LDH) activity (marker of cellular ATP) was observed. Taken together, the hepatotoxicity of EOMABRSL could be due to the depletion of LDH and induction of oxidative damage, which may suggest possible health hazards in subjects with occupational or environmental exposure. © The Author(s) 2015.
Empiric auto-titrating CPAP in people with suspected obstructive sleep apnea.
Drummond, Fitzgerald; Doelken, Peter; Ahmed, Qanta A; Gilbert, Gregory E; Strange, Charlie; Herpel, Laura; Frye, Michael D
2010-04-15
Efficient diagnosis and treatment of obstructive sleep apnea (OSA) can be difficult because of time delays imposed by clinic visits and serial overnight polysomnography. In some cases, it may be desirable to initiate treatment for suspected OSA prior to polysomnography. Our objective was to compare the improvement of daytime sleepiness and sleep-related quality of life of patients with high clinical likelihood of having OSA who were randomly assigned to receive empiric auto-titrating continuous positive airway pressure (CPAP) while awaiting polysomnogram versus current usual care. Serial patients referred for overnight polysomnography who had high clinical likelihood of having OSA were randomly assigned to usual care or immediate initiation of auto-titrating CPAP. Epworth Sleepiness Scale (ESS) scores and the Functional Outcomes of Sleep Questionnaire (FOSQ) scores were obtained at baseline, 1 month after randomization, and again after initiation of fixed CPAP in control subjects and after the sleep study in auto-CPAP patients. One hundred nine patients were randomized. Baseline demographics, daytime sleepiness, and sleep-related quality of life scores were similar between groups. One-month ESS and FOSQ scores were improved in the group empirically treated with auto-titrating CPAP. ESS scores improved in the first month by a mean of -3.2 (confidence interval -1.6 to -4.8, p < 0.001) and FOSQ scores improved by a mean of 1.5, (confidence interval 0.5 to 2.7, p = 0.02), whereas scores in the usual-care group did not change (p = NS). Following therapy directed by overnight polysomnography in the control group, there were no differences in ESS or FOSQ between the groups. No adverse events were observed. Empiric auto-CPAP resulted in symptomatic improvement of daytime sleepiness and sleep-related quality of life in a cohort of patients awaiting polysomnography who had a high pretest probability of having OSA. Additional studies are needed to evaluate the applicability of empiric treatment to other populations.
ERIC Educational Resources Information Center
Steslow, Donna M.
2010-01-01
Alternative dispute resolution (ADR) is normally included as part of an introductory business law/legal environment course. While some business schools offer stand-alone ADR courses, the majority do not. As a result, a business student's only exposure to ADR processes may be through a Legal Studies in Business course. Several scholars have created…
Equipment for linking the AutoAnalyzer on-line to a computer
Simpson, D.; Sims, G. E.; Harrison, M. I.; Whitby, L. G.
1971-01-01
An Elliott 903 computer with 8K central core store and magnetic tape backing store has been operated for approximately 20 months in a clinical chemistry laboratory. Details of the equipment designed for linking AutoAnalyzers on-line to the computer are described, and data presented concerning the time required by the computer for different processes. The reliability of the various components in daily operation is discussed. Limitations in the system's capabilities have been defined, and ways of overcoming these are delineated. At present, routine operations include the preparation of worksheets for a limited range of tests (five channels), monitoring of up to 11 AutoAnalyzer channels at a time on a seven-day week basis (with process control and automatic calculation of results), and the provision of quality control data. Cumulative reports can be printed out on those analyses for which computer-prepared worksheets are provided but the system will require extension before these can be issued sufficiently rapidly for routine use. PMID:5551384
An auto-adaptive optimization approach for targeting nonpoint source pollution control practices.
Chen, Lei; Wei, Guoyuan; Shen, Zhenyao
2015-10-21
To solve computationally intensive and technically complex control of nonpoint source pollution, the traditional genetic algorithm was modified into an auto-adaptive pattern, and a new framework was proposed by integrating this new algorithm with a watershed model and an economic module. Although conceptually simple and comprehensive, the proposed algorithm would search automatically for those Pareto-optimality solutions without a complex calibration of optimization parameters. The model was applied in a case study in a typical watershed of the Three Gorges Reservoir area, China. The results indicated that the evolutionary process of optimization was improved due to the incorporation of auto-adaptive parameters. In addition, the proposed algorithm outperformed the state-of-the-art existing algorithms in terms of convergence ability and computational efficiency. At the same cost level, solutions with greater pollutant reductions could be identified. From a scientific viewpoint, the proposed algorithm could be extended to other watersheds to provide cost-effective configurations of BMPs.
Allosteric auto-inhibition and activation of the Nedd4 family E3 ligase Itch.
Zhu, Kang; Shan, Zelin; Chen, Xing; Cai, Yuqun; Cui, Lei; Yao, Weiyi; Wang, Zhen; Shi, Pan; Tian, Changlin; Lou, Jizhong; Xie, Yunli; Wen, Wenyu
2017-09-01
The Nedd4 family E3 ligases are key regulators of cell growth and proliferation and are often misregulated in human cancers and other diseases. The ligase activities of Nedd4 E3s are tightly controlled via auto-inhibition. However, the molecular mechanism underlying Nedd4 E3 auto-inhibition and activation is poorly understood. Here, we show that the WW domains proceeding the catalytic HECT domain play an inhibitory role by binding directly to HECT in the Nedd4 E3 family member Itch. Our structural and biochemical analyses of Itch reveal that the WW2 domain and a following linker allosterically lock HECT in an inactive state inhibiting E2-E3 transthiolation. Binding of the Ndfip1 adaptor or JNK1-mediated phosphorylation relieves the auto-inhibition of Itch in a WW2-dependent manner. Aberrant activation of Itch leads to migration defects of cortical neurons during development. Our study provides a new mechanism governing the regulation of Itch. © 2017 The Authors.
A dedicated on-line detecting system for auto air dryers
NASA Astrophysics Data System (ADS)
Shi, Chao-yu; Luo, Zai
2013-10-01
According to the correlative automobile industry standard and the requirements of manufacturer, this dedicated on-line detecting system is designed against the shortage of low degree automatic efficiency and detection precision of auto air dryer in the domestic. Fast automatic detection is achieved by combining the technology of computer control, mechatronics and pneumatics. This system can detect the speciality performance of pressure regulating valve and sealability of auto air dryer, in which online analytical processing of test data is available, at the same time, saving and inquiring data is achieved. Through some experimental analysis, it is indicated that efficient and accurate detection of the performance of auto air dryer is realized, and the test errors are less than 3%. Moreover, we carry out the type A evaluation of uncertainty in test data based on Bayesian theory, and the results show that the test uncertainties of all performance parameters are less than 0.5kPa, which can meet the requirements of operating industrial site absolutely.
Conditional Poisson models: a flexible alternative to conditional logistic case cross-over analysis.
Armstrong, Ben G; Gasparrini, Antonio; Tobias, Aurelio
2014-11-24
The time stratified case cross-over approach is a popular alternative to conventional time series regression for analysing associations between time series of environmental exposures (air pollution, weather) and counts of health outcomes. These are almost always analyzed using conditional logistic regression on data expanded to case-control (case crossover) format, but this has some limitations. In particular adjusting for overdispersion and auto-correlation in the counts is not possible. It has been established that a Poisson model for counts with stratum indicators gives identical estimates to those from conditional logistic regression and does not have these limitations, but it is little used, probably because of the overheads in estimating many stratum parameters. The conditional Poisson model avoids estimating stratum parameters by conditioning on the total event count in each stratum, thus simplifying the computing and increasing the number of strata for which fitting is feasible compared with the standard unconditional Poisson model. Unlike the conditional logistic model, the conditional Poisson model does not require expanding the data, and can adjust for overdispersion and auto-correlation. It is available in Stata, R, and other packages. By applying to some real data and using simulations, we demonstrate that conditional Poisson models were simpler to code and shorter to run than are conditional logistic analyses and can be fitted to larger data sets than possible with standard Poisson models. Allowing for overdispersion or autocorrelation was possible with the conditional Poisson model but when not required this model gave identical estimates to those from conditional logistic regression. Conditional Poisson regression models provide an alternative to case crossover analysis of stratified time series data with some advantages. The conditional Poisson model can also be used in other contexts in which primary control for confounding is by fine stratification.
Muñoz, C; Young, H; Antileo, C; Bornhardt, C
2009-01-01
This paper presents a sliding mode controller (SMC) for dissolved oxygen (DO) in an integrated nitrogen removal process carried out in a suspended biomass sequencing batch reactor (SBR). The SMC performance was compared against an auto-tuning PI controller with parameters adjusted at the beginning of the batch cycle. A method for cancelling the slow DO sensor dynamics was implemented by using a first order model of the sensor. Tests in a lab-scale reactor showed that the SMC offers a better disturbance rejection capability than the auto-tuning PI controller, furthermore providing reasonable performance in a wide range of operation. Thus, SMC becomes an effective robust nonlinear tool to the DO control in this process, being also simple from a computational point of view, allowing its implementation in devices such as industrial programmable logic controllers (PLCs).
Seidlerová, Jitka; Gelžinský, Julius; Mateřánková, Markéta; Ceral, Jiří; König, Petr; Filipovský, Jan
2018-03-22
Several papers reported that unattended automated office blood pressure (uAutoOBP) is closely related to daytime ambulatory blood pressure monitoring (ABPM). In the present study, we aim to study uAutoOBP and its relation to 24-hour ABPM and ABPM variability. Stable treated hypertensive subjects were examined in two Czech academic hypertension centres. uAutoOBP was measured with the BP Tru device; attended BP three times with auscultatory method (AuscOBP) by the physician. ABPM was performed within one week from the clinical visit. Data on 98 subjects aged 67.7 ± 9.3 years with 24-hour ABPM 120.3 ± 10.6/72.7 ± 7.9 mm Hg are reported. uAutoOBP was lower than 24-hour (by -5.2 ± 11.3/-0.5 ± 6.9 mm Hg) and daytime (by -6.7 ± 12.82.4 ± 8.0 mm Hg) ABPM and the individual variability of the difference was very large (up to 30 mm Hg). The correlation coefficients between ABPM and uAutoOBP were similar compared to AuscOBP (p ≥ .17). Variability of uAutoOBP, but not AuscOBP, readings during one clinical visit was related to short-term blood pressure variability of ABPM. The difference between AuscOBP and uAutoOBP was larger in patients with white-coat effect compared to other blood pressure control groups (25.1 ± 7.0 vs. 2.2 ± 10.3 mm Hg; p = .0036). Our study shows that uAutoOBP is not good predictor of ambulatory blood pressure monitoring, not even of the daytime values. It might, however, indicate short-term blood pressure variability and, when compared with AuscOBP, also detect patients with white-coat effect.
Dumeier, Henriette Karoline; Richter, Luca Anne; Neininger, Martina Patrizia; Prenzel, Freerk; Kiess, Wieland; Bertsche, Astrid; Bertsche, Thilo
2018-04-01
Epinephrine auto-injectors are used for first aid in anaphylactic emergencies by non-healthcare professionals, e.g., (pre-)school teachers. We developed an education session for preschool teachers addressing allergies, anaphylactic emergencies, and administering auto-injectors. We assessed their attitudes and knowledge in allergies and anaphylactic emergency by a questionnaire and monitored their practical performance in administering auto-injectors before the education session, directly after, and 4-12 weeks after the session. From 75 teachers giving their consent to participate, 81% had children with allergies under their supervision and 3% had already administered medication from an available rescue kit. The knowledge of triggers of allergies increased from 9 to 55% directly and to 33% 4-12 weeks after the session (both p < 0.001, compared to baseline). Directly after the session, the number of teachers who felt well-prepared for an anaphylactic emergency rose from 11 to 88%, which decreased to 79% 4-12 weeks thereafter (each p < 0.001). The number of auto-injector administrations without any drug-related problems increased from 3 to 35% directly after the session and shrunk to 16% 4-12 weeks afterwards (both p < 0.025). A single education session substantially improved preschool teachers' attitudes and knowledge in allergies and anaphylactic emergencies. Additionally, their practical performance in auto-injector administration increased. What is Known: • Food allergies are increasing among children. • The knowledge about allergies and anaphylactic emergencies is poor. What is New: • The proportion of teachers who felt well-prepared for an anaphylactic emergency increased after a single education session. • The proportion of auto-injector administrations without any drug-related problems additionally increased due to an education session.
Natalini, Giuseppe; Tuzzo, Daniele; Rosano, Antonio; Testa, Marco; Grazioli, Michele; Pennestrì, Vincenzo; Amodeo, Guido; Berruto, Francesco; Fiorillo, Marialinda; Peratoner, Alberto; Tinnirello, Andrea; Filippini, Matteo; Marsilia, Paolo F; Minelli, Cosetta; Bernardini, Achille
2016-12-01
In some patients with auto-positive end-expiratory pressure (auto-PEEP), application of PEEP lower than auto-PEEP maintains a constant total PEEP, therefore reducing the inspiratory threshold load without detrimental cardiovascular or respiratory effects. We refer to these patients as "complete PEEP-absorbers." Conversely, adverse effects of PEEP application could occur in patients with auto-PEEP when the total PEEP rises as a consequence. From a pathophysiological perspective, all subjects with flow limitation are expected to be "complete PEEP-absorbers," whereas PEEP should increase total PEEP in all other patients. This study aimed to empirically assess the extent to which flow limitation alone explains a "complete PEEP-absorber" behavior (i.e., absence of further hyperinflation with PEEP), and to identify other factors associated with it. One hundred patients with auto-PEEP of at least 5 cmH2O at zero end-expiratory pressure (ZEEP) during controlled mechanical ventilation were enrolled. Total PEEP (i.e., end-expiratory plateau pressure) was measured both at ZEEP and after applied PEEP equal to 80 % of auto-PEEP measured at ZEEP. All measurements were repeated three times, and the average value was used for analysis. Forty-seven percent of the patients suffered from chronic pulmonary disease and 52 % from acute pulmonary disease; 61 % showed flow limitation at ZEEP, assessed by manual compression of the abdomen. The mean total PEEP was 7 ± 2 cmH2O at ZEEP and 9 ± 2 cmH2O after the application of PEEP (p < 0.001). Thirty-three percent of the patients were "complete PEEP-absorbers." Multiple logistic regression was used to predict the behavior of "complete PEEP-absorber." The best model included a respiratory rate lower than 20 breaths/min and the presence of flow limitation. The predictive ability of the model was excellent, with an overoptimism-corrected area under the receiver operating characteristics curve of 0.89 (95 % CI 0.80-0.97). Expiratory flow limitation was associated with both high and complete "PEEP-absorber" behavior, but setting a relatively high respiratory rate on the ventilator can prevent from observing complete "PEEP-absorption." Therefore, the effect of PEEP application in patients with auto-PEEP can be accurately predicted at the bedside by measuring the respiratory rate and observing the flow-volume loop during manual compression of the abdomen.
Schmidt, Thomas; Seipelt, Maria; Tackenberg, Björn; Möbs, Christian; Ghoreschi, Kamran; Hertl, Michael; Eming, Rüdiger
2016-01-01
Pemphigus is an autoimmune disease in which IgG auto-antibodies (auto-ab) against the desmosomal cadherins desmoglein (Dsg) 3 and Dsg1 cause loss of epidermal keratinocyte adhesion. Aim of this study was to investigate cytokines derived from antigen-presenting cells (APC) and their relation to CD4+ T cell subpopulations and to the auto-ab response in pemphigus. In this regard, patients with pemphigus were compared to patients with myasthenia gravis (MG), an unrelated auto-ab–mediated autoimmune disease, and healthy controls. In pemphigus and MG, the plasma concentrations of the APC-derived immunomodulatory cytokine IL-27 were highly increased. Strikingly, IL-27 strongly correlated with Dsg-specific IgG auto-ab titers. T helper (Th) 17 cells were augmented in both pemphigus and MG patients while T follicular helper (Tfh) cells, which are essential in providing B cell help, were increased only in pemphigus along with increasing plasma concentrations of IL-21, a cytokine produced by Th17 and Tfh cells. Moreover, we could detect Dsg3-specific autoreactive T cells producing IL-21 upon ex vivo stimulation with Dsg3. These findings suggest that IL-27 and IL-21-producing T cells, are involved in the pathogenesis of pemphigus. The further characterization of IL-21-producing T cells and of the role of IL-27 will lead to a more defined understanding of the auto-ab response in pemphigus. PMID:26872212
Control of autogenous activation of Herbaspirillum seropedicae nifA promoter by the IHF protein.
Wassem, Roseli; Pedrosa, Fábio O; Yates, Marshall G; Rego, Fabiane G M; Chubatsu, Leda S; Rigo, Liu U; Souza, Emanuel M
2002-07-02
Analysis of the expression of the Herbaspirillum seropedicae nifA promoter in Escherichia coli and Herbaspirillum seropedicae, showed that nifA expression is primarily dependent on NtrC but also required NifA for maximal expression under nitrogen-fixing conditions. Deletion of the IHF (integration host factor)-binding site produced a promoter with two-fold higher activity than the native promoter in the H. seropedicae wild-type strain but not in a nifA strain, indicating that IHF controls NifA auto-activation. IHF is apparently required to prevent overexpression of the NifA protein via auto-activation under nitrogen-fixing conditions in H. seropedicae.
DAT positivity in blood donors: a perplexing scenario.
Bedi, Ravneet Kaur; Mittal, Kshitija; Sood, Tanvi; Kumar, Rakesh; Praveen, Ajay S
2014-04-01
A blood request was received for 70 year male patient suffering from Chronic Obstructive Pulmonary Disease with anemia. One unit was found incompatible in AHG phase. Patient's antibody screen, indirect antiglobulin test (IAT), direct antiglobulin test (DAT) and auto control was negative. DAT of donor unit was positive with anti IgG gel card and negative with C3d reagent along with positive auto control. Donor was 30 year male with no history of blood transfusion and medication and had no evidence of hemolysis. Donors with positive DAT should be deferred, notified and referred to physician but further studies are required. Copyright © 2014 Elsevier Ltd. All rights reserved.
Htut, Myo; D'Souza, Anita; Krishnan, Amrita; Bruno, Benedetto; Zhang, Mei-Jie; Fei, Mingwei; Diaz, Miguel Angel; Copelan, Edward; Ganguly, Siddhartha; Hamadani, Mehdi; Kharfan-Dabaja, Mohamed; Lazarus, Hillard; Lee, Cindy; Meehan, Kenneth; Nishihori, Taiga; Saad, Ayman; Seo, Sachiko; Ramanathan, Muthalagu; Usmani, Saad Z; Gasparetto, Christina; Mark, Tomer M; Nieto, Yago; Hari, Parameswaran
2018-03-01
We compared postrelapse overall survival (OS) after autologous/allogeneic (auto/allo) versus tandem autologous (auto/auto) hematopoietic cell transplantation (HCT) in patients with multiple myeloma (MM). Postrelapse survival of patients receiving an auto/auto or auto/allo HCT for MM and prospectively reported to the Center for International Blood and Marrow Transplant Research between 2000 and 2010 were analyzed. Relapse occurred in 404 patients (72.4%) in the auto/auto group and in 178 patients (67.4%) in the auto/allo group after a median follow-up of 8.5 years. Relapse occurred before 6 months after a second HCT in 46% of the auto/allo patients, compared with 26% of the auto/auto patients. The 6-year postrelapse survival was better in the auto/allo group compared with the auto/auto group (44% versus 35%; P = .05). Mortality due to MM was 69% (n = 101) in the auto/allo group and 83% (n = 229) deaths in auto/auto group. In multivariate analysis, both cohorts had a similar risk of death in the first year after relapse (hazard ratio [HR], .72; P = .12); however, for time points beyond 12 months after relapse, overall survival was superior in the auto/allo cohort (HR for death in auto/auto =1.55; P = .005). Other factors associated with superior survival were enrollment in a clinical trial for HCT, male sex, and use of novel agents at induction before HCT. Our findings shown superior survival afterrelapse in auto/allo HCT recipients compared with auto/auto HCT recipients. This likely reflects a better response to salvage therapy, such as immunomodulatory drugs, potentiated by a donor-derived immunologic milieu. Further augmentation of the post-allo-HCT immune system with new immunotherapies, such as monoclonal antibodies, checkpoint inhibitors, and others, merit investigation. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
CIRCULATORY FAILURE DURING NON-INHALED FORMS OF CYANIDE INTOXICATION
Haouzi, Philippe; Tubbs, Nicole; Rannals, Matthew D.; Judenherc-Haouzi, Annick; Cabell, Larry A.; McDonough, Joe A.; Sonobe, Takashi
2016-01-01
Our objective was to determine how circulatory failure develops following systemic administration of potassium cyanide (KCN). We used a non-inhaled modality of intoxication, wherein the change in breathing pattern would not influence the diffusion of CN into the blood, akin to the effects of ingesting toxic levels of CN. In a group of 300–400 g rats, CN-induced coma (CN IP, 7 mg/kg) produced a central apnea within 2–3 minutes along with a potent and prolonged gasping pattern leading to auto-resuscitation in 38% of the animals. Motor deficits and neuronal necrosis were nevertheless observed in the surviving animals. To clarify the mechanisms leading to potential auto-resuscitation versus asystole, 12 urethane-anesthetized rats were then exposed to the lowest possible levels of CN exposure that would lead to breathing depression within 7–8 minutes; this dose averaged 0.375 mg/kg/min iv. At this level of intoxication, a cardiac depression developed several minutes only after the onset of the apnea, leading to cardiac asystole as PaO2 reached value around 15 Torr, unless breathing was maintained by mechanical ventilation or through spontaneous gasping. Higher levels of KCN exposure in 10 animals provoked a primary cardiac depression, which led to a rapid cardiac arrest by pulseless electrical activity despite the maintenance of PaO2 by mechanical ventilation. These effects were totally unrelated to the potassium contained in KCN. It is concluded that circulatory failure can develop as a direct consequence of CN induced apnea but in a narrow range of exposure. In this “low” range, maintaining pulmonary gas exchange after exposure, through mechanical ventilation (or spontaneous gasping) can reverse cardiac depression and restore spontaneous breathing. At higher level of intoxication, cardiac depression is to be treated as a specific and spontaneously irreversible consequence of CN exposure, leading to a pulseless electrical activity. PMID:27513083
Barros, Marcos Roberto Andrade Costa; Bertolami, Marcelo Chiara; Abdalla, Dulcinéia Saes Parra; Ferreira, Waldinai Pereira
2006-01-01
Oxidative modification of low-density lipoproteins (LDL) is an essential step in atherogenesis, generating minimally oxidized LDL, also called electronegative LDL [LDL(-)], which has chemotactic, cytotoxic and immunogenic properties. Serum LDL(-) and anti-LDL(-) auto-antibodies (IgG) were evaluated in 28 children and adolescents with familial hypercholesterolemia (FH) antecedents, with or without early coronary artery disease in first-degree relatives (eCAD), hypercholesterolemic (hc) or normocholesterolemic (nc) versus a control group of normocholesterolemic children without pathologic antecedents (C). ELISA method was used for detection of LDL(-) and anti-LDL(-) IgG. LDL(-) serum levels did not differ among the four groups (FH-eCAD-hc 41.4 +/- 24.9 microg/dl; FH-hc 38.3 +/- 11.2 microg/dl; FH-nc 47.3 +/- 17.0 microg/dl and C 44.2 +/- 28.8 microg/dl, p = 0.659). However, IgG anti-LDL(-) auto-antibodies were significantly higher in the control group in comparison to the FH groups with or without eCAD, independent of hypercholesterolemia or normocholesterolemia (FH-eCAD-hc 0.825 +/- 0.289 microg/dl; FH-hc 0.667 +/- 0.307 microg/dl; FH-nc 0.763 +/- 0.204 microg/dl and C 1.105 +/- 0.233 microg/dl, p = 0.006). When the auto-antibodies of groups with FH, with or without eCAD and with or without hypercholesterolemia were compared, no differences were found (p = 0.509). These results showed that FH and/or eCAD children and adolescents have lower titers of auto-antibodies anti-LDL(-) than children from normal families, independent of serum LDL-cholesterol or serum LDL(-).
Thongrakard, Ticha; Wiwatwarrapan, Chairat
2016-08-01
This study evaluated the effect of chemical surface treatment using methyl formate-methyl acetate (MF-MA) solution on the tensile bond strength between acrylic denture teeth and auto-polymerized acrylic resin. Seventy maxillary central incisor acrylic denture teeth for each of three different brands (Yamahachi New Ace; Major Dent; Cosmo HXL) were embedded with incisal edge downwards in auto-polymerized resin in polyethylene pipes and ground with silicone carbide paper on their ridge lap surfaces. The teeth of each brand were divided into seven groups (n=10): no surface treatment (control group), MF-MA solution at a ratio of 25:75 (v/v) for 15 seconds, 30 seconds, 60 seconds, 120 seconds, 180 seconds, and MMA for 180 seconds. Auto-polymerized acrylic resin (Unifast Trad) was applied to the ground surface and polymerized in a pressure cooker. A tensile strength test was performed with a universal testing machine. Statistical analysis of the results was performed using two-way analysis of variance (ANOVA) and post-hoc Dunnett T3 test (α=.05). The surface treatment groups had significantly higher mean tensile bond strengths compared with the control group (P<.05) when compared within the same brand. Among the surface treatment groups of each brand, there were no significantly different tensile bond strengths between the MF-MA groups and the MMA 180 second group (P>.05), except for the Yamahachi New Ace MF-MA 180-second group (P<.05). 15-second MF-MA solution can be an alternative chemical surface treatment for repairing a denture base and rebonding acrylic denture teeth with auto-polymerized acrylic resin, for both conventional and cross-linked teeth.
Explicit control of adaptive automation under different levels of environmental stress.
Sauer, Jürgen; Kao, Chung-Shan; Wastell, David; Nickel, Peter
2011-08-01
This article examines the effectiveness of three different forms of explicit control of adaptive automation under low- and high-stress conditions, operationalised by different levels of noise. In total, 60 participants were assigned to one of three types of automation design (free, prompted and forced choice). They were trained for 4 h on a highly automated simulation of a process control environment, called AutoCAMS. This was followed by a 4-h testing session under noise exposure and quiet conditions. Measures of performance, psychophysiology and subjective reactions were taken. The results showed that all three modes of explicit control of adaptive automation modes were able to attenuate the negative effects of noise. This was partly due to the fact that operators opted for higher levels of automation under noise. It also emerged that forced choice showed marginal advantages over the two other automation modes. Statement of Relevance: This work is relevant to the design of adaptive automation since it emphasises the need to consider the impact of work-related stressors during task completion. During the presence of stressors, different forms of operator support through automation may be required than under more favourable working conditions.
Stepanova, Eugenia; Karmaus, Wilfried; Naboka, Marina; Vdovenko, Vitaliy; Mousseau, Tim; Shestopalov, Viacheslav M; Vena, John; Svendsen, Erik; Underhill, Dwight; Pastides, Harris
2008-01-01
Background After the Chernobyl nuclear accident on April 26, 1986, all children in the contaminated territory of the Narodichesky region, Zhitomir Oblast, Ukraine, were obliged to participate in a yearly medical examination. We present the results from these examinations for the years 1993 to 1998. Since the hematopoietic system is an important target, we investigated the association between residential soil density of 137Caesium (137Cs) and hemoglobin concentration, and erythrocyte, platelet, and leukocyte counts in 1,251 children, using 4,989 repeated measurements taken from 1993 to 1998. Methods Soil contamination measurements from 38 settlements were used as exposures. Blood counts were conducted using the same auto-analyzer in all investigations for all years. We used linear mixed models to compensate for the repeated measurements of each child over the six year period. We estimated the adjusted means for all markers, controlling for potential confounders. Results Data show a statistically significant reduction in red and white blood cell counts, platelet counts and hemoglobin with increasing residential 137Cs soil contamination. Over the six-year observation period, hematologic markers did improve. In children with the higher exposure who were born before the accident, this improvement was more pronounced for platelet counts, and less for red blood cells and hemoglobin. There was no exposure×time interaction for white blood cell counts and not in 702 children who were born after the accident. The initial exposure gradient persisted in this sub-sample of children. Conclusion The study is the first longitudinal analysis from a large cohort of children after the Chernobyl accident. The findings suggest persistent adverse hematological effects associated with residential 137Cs exposure. PMID:18513393
Data transmission system with distributed microprocessors
Nambu, Shigeo
1985-01-01
A data transmission system having a common request line and a special request line in addition to a transmission line. The special request line has priority over the common request line. A plurality of node stations are multi-drop connected to the transmission line. Among the node stations, a supervising station is connected to the special request line and takes precedence over other slave stations to become a master station. The master station collects data from the slave stations. The station connected to the common request line can assign a master control function to any station requesting to be assigned the master control function within a short period of time. Each station has an auto response control circuit. The master station automatically collects data by the auto response controlling circuit independently of the microprocessors of the slave stations.
Udonwa, N. E.; Uko, E. K.; Ikpeme, B. M.; Ibanga, I. A.; Okon, B. O.
2009-01-01
A population-based-cross-sectional survey was carried out to investigate the potential risk of exposure to premium motor spirit (PMS) fumes in Calabar, Nigeria, among Automobile Mechanics (AM), Petrol Station Attendants (PSA) and the general population. Structured questionnaire was administered on the randomly chosen subjects to elicit information on their exposure to PMS. Duration of exposure was taken as the length of work in their various occupations. Venous blood was taken for methaemoglobin (MetHb) and packed cells volume (PCV). Mean MetHb value was higher in AM (7.3%) and PSA (5.8%) than in the subjects from the general population (2.7%). PCV was lower in PSA (30.8%), than AM (33.3%) and the subjects from the general population (40.8%). MetHb level was directly proportional, and PCV inversely related, to the duration of exposure. The study suggested increased exposure to petrol fumes among AM, PSA, and MetHb as a useful biomarker in determining the level of exposure to benzene in petrol vapour. PMID:19936128
Major sources of benzene exposure.
Wallace, L A
1989-01-01
Data from EPA's TEAM Study allow us to identify the major sources of exposure to benzene for much of the U.S. population. These sources turn out to be quite different from what had previously been considered the important sources. The most important source of exposure for 50 million smokers is the mainstream smoke from their cigarettes, which accounts for about half of the total population burden of exposure to benzene. Another 20% of nationwide exposure is contributed by various personal activities, such as driving and using attached garages. (Emissions from consumer products, building materials, paints, and adhesives may also be important, although data are largely lacking.) The traditional sources of atmospheric emissions (auto exhaust and industrial emissions) account for only about 20% of total exposure. Environmental tobacco smoke is an important source, accounting for about 5% of total nationwide exposure. A number of sources sometimes considered important, such as petroleum refining operations, petrochemical manufacturing, oil storage tanks, urban-industrial areas, service stations, certain foods, groundwater contamination, and underground gasoline leaks, appear to be unimportant on a nationwide basis. PMID:2477239
NASA Astrophysics Data System (ADS)
Holland, S. Douglas
1992-09-01
A handheld, programmable, digital camera is disclosed that supports a variety of sensors and has program control over the system components to provide versatility. The camera uses a high performance design which produces near film quality images from an electronic system. The optical system of the camera incorporates a conventional camera body that was slightly modified, thus permitting the use of conventional camera accessories, such as telephoto lenses, wide-angle lenses, auto-focusing circuitry, auto-exposure circuitry, flash units, and the like. An image sensor, such as a charge coupled device ('CCD') collects the photons that pass through the camera aperture when the shutter is opened, and produces an analog electrical signal indicative of the image. The analog image signal is read out of the CCD and is processed by preamplifier circuitry, a correlated double sampler, and a sample and hold circuit before it is converted to a digital signal. The analog-to-digital converter has an accuracy of eight bits to insure accuracy during the conversion. Two types of data ports are included for two different data transfer needs. One data port comprises a general purpose industrial standard port and the other a high speed/high performance application specific port. The system uses removable hard disks as its permanent storage media. The hard disk receives the digital image signal from the memory buffer and correlates the image signal with other sensed parameters, such as longitudinal or other information. When the storage capacity of the hard disk has been filled, the disk can be replaced with a new disk.
NASA Technical Reports Server (NTRS)
Holland, S. Douglas (Inventor)
1992-01-01
A handheld, programmable, digital camera is disclosed that supports a variety of sensors and has program control over the system components to provide versatility. The camera uses a high performance design which produces near film quality images from an electronic system. The optical system of the camera incorporates a conventional camera body that was slightly modified, thus permitting the use of conventional camera accessories, such as telephoto lenses, wide-angle lenses, auto-focusing circuitry, auto-exposure circuitry, flash units, and the like. An image sensor, such as a charge coupled device ('CCD') collects the photons that pass through the camera aperture when the shutter is opened, and produces an analog electrical signal indicative of the image. The analog image signal is read out of the CCD and is processed by preamplifier circuitry, a correlated double sampler, and a sample and hold circuit before it is converted to a digital signal. The analog-to-digital converter has an accuracy of eight bits to insure accuracy during the conversion. Two types of data ports are included for two different data transfer needs. One data port comprises a general purpose industrial standard port and the other a high speed/high performance application specific port. The system uses removable hard disks as its permanent storage media. The hard disk receives the digital image signal from the memory buffer and correlates the image signal with other sensed parameters, such as longitudinal or other information. When the storage capacity of the hard disk has been filled, the disk can be replaced with a new disk.
Remote control radioactive-waste removal system uses modulated laser transmitter
NASA Technical Reports Server (NTRS)
Burcher, E. E.; Kopia, L. P.; Rowland, C. W.; Sinclair, A. R.
1971-01-01
Laser remote control system consists of transmitter, auto tracker, and receiver. Transmitter and tracker, packaged together and bore sighted, constitute control station, receiver is slave station. Model has five command channels and optical link operating range of 110 m.
Chemotaxis and auto-chemotaxis of self-propelling artificial droplet swimmers
NASA Astrophysics Data System (ADS)
Jin, Chenyu; Krueger, Carsten; Maass, Corinna
Chemotaxis and auto-chemotaxis are key mechanisms in the dynamics of micro-organisms, e.g. in the acquisition of nutrients and in the communication between individuals, influencing the collective behavior. However, chemical signalling and the natural environment of biological swimmers are generally complex, making them hard to access analytically. Simple experimental systems showing similar features could provide vital insights. We present such a swimmer system, as well as controlled assays to study chemotactic effects quantitatively and reproducibly. In our experiments, we let auto-chemotactic droplet swimmers pass through bifurcating microfluidic channels and record anticorrelations between the branch choices of consecutive droplets. We present an analytical model based on balancing stochastic forces versus a diffusing chemical gradient matching the experimental data. supported by the DFG SPP 1726 ''Microswimmers'' and the MaxSynBio network.
An improved maximum power point tracking method for a photovoltaic system
NASA Astrophysics Data System (ADS)
Ouoba, David; Fakkar, Abderrahim; El Kouari, Youssef; Dkhichi, Fayrouz; Oukarfi, Benyounes
2016-06-01
In this paper, an improved auto-scaling variable step-size Maximum Power Point Tracking (MPPT) method for photovoltaic (PV) system was proposed. To achieve simultaneously a fast dynamic response and stable steady-state power, a first improvement was made on the step-size scaling function of the duty cycle that controls the converter. An algorithm was secondly proposed to address wrong decision that may be made at an abrupt change of the irradiation. The proposed auto-scaling variable step-size approach was compared to some various other approaches from the literature such as: classical fixed step-size, variable step-size and a recent auto-scaling variable step-size maximum power point tracking approaches. The simulation results obtained by MATLAB/SIMULINK were given and discussed for validation.
Studies in the epidemiology of prostatic cancer: expanded sampling.
Rotkin, I D
1977-01-01
From comparisons of prostatic cancer patients with matched control patients for selected risk variables, patients are characterized by three main trends: (a) delayed sexual drive and development, (b) early repression of sexuality, and (c) premature cessation of sexuality. Excessive numbers of patients reported occupational exposure to fertilizers and auto exhaust fumes. Diets of the patients were higher in animal fats. No differences were found between both groups for frequencies of multiple marriages or sex partners, nor for stressful effects from selected events early or late in life. Trends for circumcision and other variables are presented. The data suggest that early differences are hormonally conditioned, support a provisional endogenous rationale for initiation of prostatic cancer, and oppose a hypothesis favoring transmissible oncogenic agents. If results continue to hold up with increased sampling, limitation upon sexual activity at any time of life may increase risk.
Velázquez, Luis; Bello, Dhimiter; Munguia, Nora; Zavala, Andrea; Marin, Amina; Moure-Eraso, Rafael
2008-01-01
The automotive repair and refinishing industry has been studied intensively in industrialized countries, in part due to use of hazardous chemicals such as isocyanates and solvents, but little is known about industry practices in the developing world. The main objective of this paper was to investigate environmental and occupational work practices of this industry in a developing region, Sonora, Mexico. An integrated survey approach maximizes the opportunity for identifying risks as well as reducing risks. This investigation included detailed workplace visits to 41 body shops and 6 paint suppliers, as well as a survey of shop owners and 24 workers. Information was collected on work practices, level of technology in the shops, use of personal protective equipment, consumption and handling of hazardous chemicals and waste, hazard communication, and environmental consciousness. Most shops had little capital, outdated technology for exposure control, poor working conditions, high potential for exposure to hazardous chemicals, and little awareness of environmental and occupational health and safety. We concluded that work practices in the Sonoran auto refinishing industry are unsustainable and may pose a health risk to workers and the environment.
1981-12-01
Haverhill, a gabion mattress ( revet - ment) underlaid with filter fabric was placed on the bank. (2) Concrete Blocks . Precast concrete blocks with filter... revetment - precast cellular concrete block mattress, used auto tire wall and used auto tire mattress. All three revetment panels included vegetative...DISTRIBUTION STATEMENT A NOV 81982 Approved fog public release; ,.* Diatribuatofl UnlimitedB - A. B .4. R ock roe With Tie-Backs Precast Block Paving
Exposure Evaluation for Benzene, Lead and Noise in Vehicle and Equipment Repair Shops
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sweeney, Lynn C.
An exposure assessment was performed at the equipment and vehicle maintenance repair shops operating at the U. S. Department of Energy Hanford site, in Richland, Washington. The maintenance shops repair and maintain vehicles and equipment used in support of the Hanford cleanup mission. There are three general mechanic shops and one auto body repair shop. The mechanics work on heavy equipment used in construction, cranes, commercial motor vehicles, passenger-type vehicles in addition to air compressors, generators, and farm equipment. Services include part fabrication, installation of equipment, repair and maintenance work in the engine compartment, and tire and brake services. Workmore » performed at the auto body shop includes painting and surface preparation which involves applying body filler and sanding. 8-hour time-weighted-average samples were collected for benzene and noise exposure and task-based samples were collected for lead dust work activities involving painted metal surfaces. Benzene samples were obtained using 3M™ 3520 sampling badges and were analyzed for additional volatile organic compounds. These compounds were selected based on material safety data sheet information for the aerosol products used by the mechanics for each day of sampling. The compounds included acetone, ethyl ether, toluene, xylene, VM&P naphtha, methyl ethyl ketone, and trichloroethylene. Laboratory data for benzene, VM&P naphtha, methyl ethyl ketone and trichloroethylene were all below the reporting detection limit. Airborne concentrations for acetone, ethyl ether, toluene and xylene were all less than 10% of their occupational exposure limit. The task-based samples obtained for lead dusts were submitted for a metal scan analysis to identify other metals that might be present. Laboratory results for lead dusts were all below the reporting detection limit and airborne concentration for the other metals observed in the samples were less than 10% of the occupational exposure limit. Noise dosimetry sampling was performed on a random basis and was representative of the different work activities within the four shops. Twenty three percent of the noise samples exceeded the occupational exposure limit of 85 decibels for an 8-hour time-weightedaverage. Work activities where noise levels were higher included use of impact wrenches and grinding wheels.« less
Alwasaidi, Turki Abdulaziz; Hamadah, Abdulaziz; Altouri, Sultan; Tay, Jason; McDiarmid, Sheryl; Faught, Carolyn; Allan, David; Huebsch, Lothar; Bredeson, Christopher; Bence-Bruckler, Isabelle
2015-12-01
We retrospectively evaluated consecutive patients diagnosed with Mantle cell lymphoma (MCL) between 01 January 2000 and 31 December 2009. Eighty eight patients with MCL were included in the analysis of whom 46 (52%) received abbreviated Hyper-CVAD (a total of two cycles; with addition of Rituximab since 2005) with an intention of proceeding to autologous hematopoietic cell transplantation (auto-HCT), with a median age of 58 years. Response rate to induction at auto-HCT time was 89% and complete response was 61%. Forty four patients received an auto-HCT with a 5-year progression-free survival (PFS) and overall survival (OS) were 31.2% and 62.5%, respectively. There were 42 nontransplant eligible patients with a median age of 72 years, and 5-year PFS and OS were 0.0% and 39.9%, respectively. The median survival and PFS in the auto-HCT eligible group were 68 and 33 months, compared to 32 and 12 months in nontransplant eligible group, without a plateauing of the survival curves in either group. Treatment-related mortality in the auto-HCT eligible group was 10.9% (n = 5); two patients died during R-Hyper-CVAD and 3 (6.8%) experienced transplant-related mortality. An abbreviated R-Hyper-CVAD-based induction strategy followed by consolidative auto-HCT is feasible and provides moderate potential of long-term survival. Further research to define risk-adapted strategies; to optimize disease control, is required. © 2015 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
Automated Computer Access Request System
NASA Technical Reports Server (NTRS)
Snook, Bryan E.
2010-01-01
The Automated Computer Access Request (AutoCAR) system is a Web-based account provisioning application that replaces the time-consuming paper-based computer-access request process at Johnson Space Center (JSC). Auto- CAR combines rules-based and role-based functionality in one application to provide a centralized system that is easily and widely accessible. The system features a work-flow engine that facilitates request routing, a user registration directory containing contact information and user metadata, an access request submission and tracking process, and a system administrator account management component. This provides full, end-to-end disposition approval chain accountability from the moment a request is submitted. By blending both rules-based and rolebased functionality, AutoCAR has the flexibility to route requests based on a user s nationality, JSC affiliation status, and other export-control requirements, while ensuring a user s request is addressed by either a primary or backup approver. All user accounts that are tracked in AutoCAR are recorded and mapped to the native operating system schema on the target platform where user accounts reside. This allows for future extensibility for supporting creation, deletion, and account management directly on the target platforms by way of AutoCAR. The system s directory-based lookup and day-today change analysis of directory information determines personnel moves, deletions, and additions, and automatically notifies a user via e-mail to revalidate his/her account access as a result of such changes. AutoCAR is a Microsoft classic active server page (ASP) application hosted on a Microsoft Internet Information Server (IIS).
Numerical simulation and validation of SI-CAI hybrid combustion in a CAI/HCCI gasoline engine
NASA Astrophysics Data System (ADS)
Wang, Xinyan; Xie, Hui; Xie, Liyan; Zhang, Lianfang; Li, Le; Chen, Tao; Zhao, Hua
2013-02-01
SI-CAI hybrid combustion, also known as spark-assisted compression ignition (SACI), is a promising concept to extend the operating range of CAI (Controlled Auto-Ignition) and achieve the smooth transition between spark ignition (SI) and CAI in the gasoline engine. In this study, a SI-CAI hybrid combustion model (HCM) has been constructed on the basis of the 3-Zones Extended Coherent Flame Model (ECFM3Z). An ignition model is included to initiate the ECFM3Z calculation and induce the flame propagation. In order to precisely depict the subsequent auto-ignition process of the unburned fuel and air mixture independently after the initiation of flame propagation, the tabulated chemistry concept is adopted to describe the auto-ignition chemistry. The methodology for extracting tabulated parameters from the chemical kinetics calculations is developed so that both cool flame reactions and main auto-ignition combustion can be well captured under a wider range of thermodynamic conditions. The SI-CAI hybrid combustion model (HCM) is then applied in the three-dimensional computational fluid dynamics (3-D CFD) engine simulation. The simulation results are compared with the experimental data obtained from a single cylinder VVA engine. The detailed analysis of the simulations demonstrates that the SI-CAI hybrid combustion process is characterised with the early flame propagation and subsequent multi-site auto-ignition around the main flame front, which is consistent with the optical results reported by other researchers. Besides, the systematic study of the in-cylinder condition reveals the influence mechanism of the early flame propagation on the subsequent auto-ignition.
Aguilar Ferrándiz, Maria Encarnación; Nijs, Jo; Gidron, Yori; Roussel, Nathalie; Vanderstraeten, Rob; Van Dyck, Dries; Huysmans, Eva; De Kooning, Margot
2016-07-01
Myofascial trigger points (MTrPs) are common in people with musculoskeletal pain and may play a role in chronic nonspecific low back pain (CLBP). One of the potential treatments of MTrPs is the Nervomatrix Soleve® auto-targeted neurostimulation device, providing targeted transcutaneous electrical nerve stimulation (TENS) to MTrPs in the lower back muscles. To date, no controlled studies have evaluated the effectiveness of this device for the pain management of this population. To examine whether the Nervomatrix Soleve® auto-targeted neurostimulation device is superior over placebo for the treatment of CLBP. A fourfold-blind randomized controlled trial was conducted. Brussels University Hospital, health care centers and pharmacies around Belgium. Participants with CLBP for at least 3 months were randomly assigned to the experimental (the Nervomatrix Soleve® auto-targeted neurostimulation device providing TENS-stimulation and mechanical pressure) or placebo group (the Nervomatrix Soleve® auto-targeted neurostimulation device providing mechanical pressure alone without current). The treatment protocol in both groups consisted of 6 treatment sessions per patient. Participants were evaluated at baseline prior to the intervention, immediately following treatment, and at one month follow-up. Pain and pain behavior (steps climbed) were assessed as primary outcome measures. Secondary outcome measures were pain functioning, health beliefs, symptoms of central sensitization, pain catastrophizing, and kinesiophobia. In total, 39 participants were included in the study. Participants in both groups improved significantly for pain and functioning, but no significant differences were observed between groups. These improvements were not clinically meaningful for any of the reported measures. The health beliefs changed significantly in both groups (P < 0.05), with superior results at follow-up in the placebo group. The follow-up period is limited to one month. Treatment of MTrPs with the Nervomatrix Soleve® auto-targeted neurostimulation device in patients with CLBP does not result in a better outcome than placebo-treatment in terms of pain, pain behavior, functioning, central sensitization, pain catastrophizing, and health beliefs.
Park, Donguk; Stewart, Patrica A.; Coble, Joseph B.
2009-01-01
An extensive literature review of published metalworking fluid (MWF) aerosol measurement data was conducted to identify the major determinants that may affect exposure to aerosol fractions (total or inhalable, thoracic and respirable) and mass median diameters (MMDs). The identification of determinants was conducted through published studies and analysis of published measurement levels. For the latter, weighted arithmetic means (WAMs) by number of measurements were calculated and compared using analysis of variance and t-tests. The literature review found that the major factors affecting aerosol exposure levels were, primarily, decade, type of industry, operation and fluid and engineering control measures. Our analysis of total aerosol levels found a significant decline in measured levels from an average of 5.36 mg m−3 prior to the 1970s and 2.52 mg m−3 in the 1970s to 1.21 mg m−3 in the 1980s, 0.50 mg m−3 in the 1990s and 0.55 mg m−3 in the 2000s. Significant declines from the 1990s to the 2000s also were found in thoracic fraction levels (0.48 versus 0.40 mg m−3), but not for the respirable fraction. The WAMs for the auto (1.47 mg m−3) and auto parts manufacturing industry (1.83 mg m−3) were significantly higher than that for small-job machine shops (0.68 mg m−3). In addition, a significant difference in the thoracic WAM was found between the automotive industry (0.46 mg m−3) and small-job machine shops (0.32 mg m−3). Operation type, in particular, grinding, was a significant factor affecting the total aerosol fraction [grinding operations (1.75 mg m−3) versus other machining (0.95 mg m−3)], but the levels associated with these operations were not statistically different for either the thoracic or the respirable fractions. Across all decades, the total aerosol fraction for straight oils (1.49 mg m−3) was higher than for other fluid types (soluble = 1.08 mg m−3, synthetic = 0.52 mg m−3 and semisynthetic = 0.50 mg m−3). Fluid type was also found to be partly associated with differences in the respirable fraction level. We found that the total aerosols were measured by a variety of sampling media, devices and analytical methods. This diversity of approaches makes interpretation of the study results difficult. In conclusion, both the literature review and the measurement data analyzed found that decade and type of industry, operation and fluid were important determinants of total aerosol exposure. Industry type and fluid type were associated with differences in exposure to the thoracic and respirable fraction levels, respectively. PMID:19329796
NASA Astrophysics Data System (ADS)
An, Shengpei; Hu, Tianyue; Liu, Yimou; Peng, Gengxin; Liang, Xianghao
2017-12-01
Static correction is a crucial step of seismic data processing for onshore play, which frequently has a complex near-surface condition. The effectiveness of the static correction depends on an accurate determination of first-arrival traveltimes. However, it is difficult to accurately auto-pick the first arrivals for data with low signal-to-noise ratios (SNR), especially for those measured in the area of the complex near-surface. The technique of the super-virtual interferometry (SVI) has the potential to enhance the SNR of first arrivals. In this paper, we develop the extended SVI with (1) the application of the reverse correlation to improve the capability of SNR enhancement at near-offset, and (2) the usage of the multi-domain method to partially overcome the limitation of current method, given insufficient available source-receiver combinations. Compared to the standard SVI, the SNR enhancement of the extended SVI can be up to 40%. In addition, we propose a quality control procedure, which is based on the statistical characteristics of multichannel recordings of first arrivals. It can auto-correct the mispicks, which might be spurious events generated by the SVI. This procedure is very robust, highly automatic and it can accommodate large data in batches. Finally, we develop one automatic first-arrival picking method to combine the extended SVI and the quality control procedure. Both the synthetic and the field data examples demonstrate that the proposed method is able to accurately auto-pick first arrivals in seismic traces with low SNR. The quality of the stacked seismic sections obtained from this method is much better than those obtained from an auto-picking method, which is commonly employed by the commercial software.
Sun, Ming-Shen; Zhang, Li; Guo, Ning; Song, Yan-Zheng; Zhang, Feng-Ju
2018-01-01
To evaluate and compare the uniformity of angle Kappa adjustment between Oculyzer and Topolyzer Vario topography guided ablation of laser in situ keratomileusis (LASIK) by EX500 excimer laser for myopia. Totally 145 cases (290 consecutive eyes )with myopia received LASIK with a target of emmetropia. The ablation for 86 cases (172 eyes) was guided manually based on Oculyzer topography (study group), while the ablation for 59 cases (118 eyes) was guided automatically by Topolyzer Vario topography (control group). Measurement of adjustment values included data respectively in horizontal and vertical direction of cornea. Horizontally, synclastic adjustment between manually actual values (dx manu ) and Oculyzer topography guided data (dx ocu ) accounts 35.5% in study group, with mean dx manu /dx ocu of 0.78±0.48; while in control group, synclastic adjustment between automatically actual values (dx auto ) and Oculyzer topography data (dx ocu ) accounts 54.2%, with mean dx auto /dx ocu of 0.79±0.66. Vertically, synclastic adjustment between dy manu and dy ocu accounts 55.2% in study group, with mean dy manu /dy ocu of 0.61±0.42; while in control group, synclastic adjustment between dy auto and dy ocu accounts 66.1%, with mean dy auto /dy ocu of 0.66±0.65. There was no statistically significant difference in ratio of actual values/Oculyzer topography guided data in horizontal and vertical direction between two groups ( P =0.951, 0.621). There is high consistency in angle Kappa adjustment guided manually by Oculyzer and guided automatically by Topolyzer Vario topography during corneal refractive surgery by WaveLight EX500 excimer laser.
Kamal, Atif; Malik, Riffat Naseem
2012-01-01
Objectives Occupational exposure to aromatic solvents causes many serious health hazards to workers, especially if an ambient environment increases the exposure during routine working hours. This study was conducted on two related groups, i.e., automobile mechanics (MCs) and automobile spray painters (PNs), with an effort to analyze effects of chemical exposure on hematological parameters, keeping a focus on environmental parameters and workers’ personal behavioral characteristics that could be held responsible for increasing exposure risk. Methods A preliminary survey of various chemicals used in these places was done, and 78 blood samples were collected from three groups (control, n = 24; mechanics, n = 25; painters, n = 29). Demographic features of workers were recorded through a short questionnaire. Results Results showed that mean red blood cell (RBC) count was lower both in MCs [t(51) = 2.38, p < 0.021, r = 0.32] and in PNs [t(47) = 2.12, p < 0.03, r = 0.29], whereas mean hemoglobin (Hb) was significantly lower in MCs [t(51) = 2.5, p = 0.017, r = 0.33]. Combined data for exposed groups for smokers (SMs) versus nonsmokers (NSs) showed that SMs had a significantly lower number (RBC count: t(52) = 2.28, p < 0.027, r = 0.25; Hb count: t(52) = 2.71, p < 0.009, r = 0.30] of these parameters than NSs, even compared to the control group. Moreover, logistic regression results showed that smoking is a significant predictor of reduction in RBC and Hb counts, besides occupational exposure and work experience to a little extent among exposed workers. Mean white blood cell count [t(47) = 2.63, p < 0.01, r=0.35], mean corpuscle volume [t(47)= –2.82, p = 0.007, r = 0.29], and packed cell volume [t(47)= –2.28, p = 0.027, r = 31] were higher exclusively in painters, which could be related to exposure to benzene in addition to isocyanate. Conclusion It appeared that workplace exposure may be complex due to interaction of multiple factors and PNs face much more exposure to isocyanate and aromatic solvents than MCs, which had significant effects on their hematopoiesis. Smoking enhances exposure risk manifolds, and among MCs it showed combined effects along with occupational exposure. There is a need to create awareness among these workers to adopt self-safety measures during routine tasks and also of a separate study to elucidate actual occupational exposure among them, eliminating confounding factors. PMID:24159519
[Study of blending method for the extracts of herbal plants].
Liu, Yongsuo; Cao, Min; Chen, Yuying; Hu, Yuzhu; Wang, Yiming; Luo, Guoan
2006-03-01
The irregularity in herbal plant composition is influenced by multiple factors. As for quality control of traditional Chinese medicine, the most critical challenge is to ensure the dosage content uniformity. This content uniformity can be improved by blending different batches of the extracts of herbal plants. Nonlinear least-squares regression was used to calculate the blending coefficient, which means no great absolute differences allowed for all ingredients. For traditional Chinese medicines, even relatively smaller differences could present to be very important for all the ingredients. The auto-scaling pretreatment was used prior to the calculation of the blending coefficients. The pretreatment buffered the characteristics of individual data for the ingredients in different batches, so an improved auto-scaling pretreatment method was proposed. With the improved auto-scaling pretreatment, the relative. differences decreased after blending different batches of extracts of herbal plants according to the reference samples. And the content uniformity control of the specific ingredients could be achieved by the error control coefficient. In the studies for the extracts of fructus gardeniae, the relative differences of all the ingredients is less than 3% after blending different batches of the extracts. The results showed that nonlinear least-squares regression can be used to calculate the blending coefficient of the herbal plant extracts.
Krishnan, Amrita; Pasquini, Marcelo C.; Logan, Brent; Stadtmauer, Edward A.; Vesole, David H.; Alyea, Edwin; Antin, Joseph H.; Comenzo, Raymond; Goodman, Stacey; Hari, Parameswaran; Laport, Ginna; Qazilbash, Muzaffar H.; Rowley, Scott; Sahebi, Firoozeh; Somlo, George; Vogl, Dan T.; Weisdorf, Daniel; Ewell, Marian; Wu, Juan; Geller, Nancy L.; Horowitz, Mary M.; Giralt, Sergio; Maloney, David G.
2012-01-01
Background Autologous hematopoietic cell transplantation (HCT) improves survival in patients with multiple myeloma, but disease progression remains a challenge. Allogeneic HCT (alloHCT) has the potential to reduce disease progression through graft-versus-myeloma effects. The aim of the BMT CTN 0102 trial was to compare outcomes of autologous HCT (autoHCT) followed by alloHCT with non-myeloablative conditioning (auto-allo) to tandem autoHCT (auto-auto) in patients with standard risk myeloma. Patients in the auto-auto arm were randomized to one year of thalidomide and dexamethasone (Thal-Dex) maintenance therapy or observation (Obs). Methods Patients with multiple myeloma within 10 months from initiation of induction therapy were classified as standard (SRD) or high risk (HRD) disease based on cytogenetics and beta-2-microglobulin levels. Assignment to auto-allo HCT was based on availability of an HLA-matched sibling donor. Primary endpoint was three-year progression-free survival (PFS) according to intent-to-treat analysis. Results 710 patients were enrolled completed a minimum of 3-year follow up. Among 625 SRD patients, 189 and 436 were assigned to auto-allo and auto-auto, respectively. Seventeen percent (33/189) of SR patients in the auto-allo arm and 16% (70/436) in the auto-auto arm did not receive a second transplant. Thal-Dex was not completed in 77% (168/217) of assigned patients. PFS and overall survival (OS) did not differ between the Thal-Dex (49%, 80%) and Obs (41%, 81%) cohorts and these two arms were pooled for analysis. Three year PFS was 43% and 46% (p=0·671) and three-year OS was 77% and 80 % (p=0·191) with auto-allo and auto-auto, respectively. Corresponding progression/relapse rates were 46% and 50% (p=0·402); treatment-related mortality rates were 11% and 4% (p<0·001), respectively. Auto/allo patients with chronic graft-vs-host disease had a decreased risk of relapse. Most common grade 3 to 5 adverse events in auto-allo was hypebilirubenemia (21/189) and in the auto-auto was peripheral neuropathy (52/436). Among 85 HRD patients (37 auto-allo), three PFS was 40% and 33% (p=0·743) and three-year OS was 59% and 67% (p=0·460) with auto-allo and auto-auto, respectively. Conclusion Thal-Dex maintenance was associated with poor compliance and did not improve PFS or OS. At three years there was no improvement in PFS or OS with auto-allo compared to auto-auto transplantation in patients with standard risk myeloma. Decisions to proceed with alloHCT after an autoHCT in patients with standard risk myeloma should take into consideration results of the current trial. Future investigation of alloHCT in myeloma should focus to minimize TRM and maximize graft-versus myeloma effects. This trial was registered in Clinicaltrials.gov (NCT00075829) and was funded by the National Heart, Lung and Blood Institute and National Cancer Institute. PMID:21962393
Klyuchnikov, Evgeny; Bacher, Ulrike; Kröger, Nicolaus M; Hari, Parameswaran N; Ahn, Kwang Woo; Carreras, Jeanette; Bachanova, Veronika; Bashey, Asad; Cohen, Jonathon B; D'Souza, Anita; Freytes, César O; Gale, Robert Peter; Ganguly, Siddhartha; Hertzberg, Mark S; Holmberg, Leona A; Kharfan-Dabaja, Mohamed A; Klein, Andreas; Ku, Grace H; Laport, Ginna G; Lazarus, Hillard M; Miller, Alan M; Mussetti, Alberto; Olsson, Richard F; Slavin, Shimon; Usmani, Saad Z; Vij, Ravi; Wood, William A; Maloney, David G; Sureda, Anna M; Smith, Sonali M; Hamadani, Mehdi
2015-12-01
This study was conducted to compare long-term outcomes in patients with refractory/relapsed grades 1 and 2 follicular lymphoma (FL) after allogeneic (allo) versus autologous (auto) hematopoietic cell transplantation (HCT) in the rituximab era. Adult patients with relapsed/refractory grades 1 and 2 FL undergoing first reduced-intensity allo-HCT or first autograft during 2000 to 2012 were evaluated. A total of 518 rituximab-treated patients were included. Allo-HCT patients were younger and more heavily pretreated, and more patients had advanced stage and chemoresistant disease. The 5-year adjusted probabilities, comparing auto-HCT versus allo-HCT groups for nonrelapse mortality (NRM) were 5% versus 26% (P < .0001); relapse/progression: 54% versus 20% (P < .0001); progression-free survival (PFS): 41% versus 58% (P < .001), and overall survival (OS): 74% versus 66% (P = .05). Auto-HCT was associated with a higher risk of relapse/progression beyond 5 months after HCT (relative risk [RR], 4.4; P < .0001) and worse PFS (RR, 2.9; P < .0001) beyond 11 months after HCT. In the first 24 months after HCT, auto-HCT was associated with improved OS (RR, .41; P < .0001), but beyond 24 months, it was associated with inferior OS (RR, 2.2; P = .006). A landmark analysis of patients alive and progression-free at 2 years after HCT confirmed these observations, showing no difference in further NRM between both groups, but there was significantly higher risk of relapse/progression (RR, 7.3; P < .0001) and inferior PFS (RR, 3.2; P < .0001) and OS (RR, 2.1; P = .04) after auto-HCT. The 10-year cumulative incidences of second hematological malignancies after allo-HCT and auto-HCT were 0% and 7%, respectively. Auto-HCT and reduced-intensity-conditioned allo-HCT as first transplantation approach can provide durable disease control in grades 1 and 2 FL patients. Continued disease relapse risk after auto-HCT translates into improved PFS and OS after allo-HCT in long-term survivors. Copyright © 2015 American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
Fast and Adaptive Auto-focusing Microscope
NASA Astrophysics Data System (ADS)
Obara, Takeshi; Igarashi, Yasunobu; Hashimoto, Koichi
Optical microscopes are widely used in biological and medical researches. By using the microscope, we can observe cellular movements including intracellular ions and molecules tagged with fluorescent dyes at a high magnification. However, a freely motile cell easily escapes from a 3D field of view of the typical microscope. Therefore, we propose a novel auto-focusing algorithm and develop a auto-focusing and tracking microscope. XYZ positions of a microscopic stage are feedback controlled to focus and track the cell automatically. A bright-field image is used to estimate a cellular position. XY centroids are used to estimate XY positions of the tracked cell. To estimate Z position, we use a diffraction pattern around the cell membrane. This estimation method is so-called Depth from Diffraction (DFDi). However, this method is not robust for individual differences between cells because the diffraction pattern depends on each cellular shape. Therefore, in this study, we propose a real-time correction of DFDi by using 2D Laplacian of an intracellular area as a goodness of the focus. To evaluate the performance of our developed algorithm and microscope, we auto-focus and track a freely moving paramecium. In this experimental result, the paramecium is auto-focused and kept inside the scope of the microscope during 45s. The evaluated focal error is within 5µm, while a length and a thickness of the paramecium are about 200µm and 50µm, respectively.
Zhou, Yunyi; Tao, Chenyang; Lu, Wenlian; Feng, Jianfeng
2018-04-20
Functional connectivity is among the most important tools to study brain. The correlation coefficient, between time series of different brain areas, is the most popular method to quantify functional connectivity. Correlation coefficient in practical use assumes the data to be temporally independent. However, the time series data of brain can manifest significant temporal auto-correlation. A widely applicable method is proposed for correcting temporal auto-correlation. We considered two types of time series models: (1) auto-regressive-moving-average model, (2) nonlinear dynamical system model with noisy fluctuations, and derived their respective asymptotic distributions of correlation coefficient. These two types of models are most commonly used in neuroscience studies. We show the respective asymptotic distributions share a unified expression. We have verified the validity of our method, and shown our method exhibited sufficient statistical power for detecting true correlation on numerical experiments. Employing our method on real dataset yields more robust functional network and higher classification accuracy than conventional methods. Our method robustly controls the type I error while maintaining sufficient statistical power for detecting true correlation in numerical experiments, where existing methods measuring association (linear and nonlinear) fail. In this work, we proposed a widely applicable approach for correcting the effect of temporal auto-correlation on functional connectivity. Empirical results favor the use of our method in functional network analysis. Copyright © 2018. Published by Elsevier B.V.
Generating Code Review Documentation for Auto-Generated Mission-Critical Software
NASA Technical Reports Server (NTRS)
Denney, Ewen; Fischer, Bernd
2009-01-01
Model-based design and automated code generation are increasingly used at NASA to produce actual flight code, particularly in the Guidance, Navigation, and Control domain. However, since code generators are typically not qualified, there is no guarantee that their output is correct, and consequently auto-generated code still needs to be fully tested and certified. We have thus developed AUTOCERT, a generator-independent plug-in that supports the certification of auto-generated code. AUTOCERT takes a set of mission safety requirements, and formally verifies that the autogenerated code satisfies these requirements. It generates a natural language report that explains why and how the code complies with the specified requirements. The report is hyper-linked to both the program and the verification conditions and thus provides a high-level structured argument containing tracing information for use in code reviews.
Design and evaluation of excitation light source device for fluorescence endoscope
NASA Astrophysics Data System (ADS)
Lim, Hyun Soo
2009-06-01
This study aims at designing and evaluating light source devices that can stably generate light with various wavelengths in order to make possible PDD using a photosensitizer and diagnosis using auto-fluorescence. The light source was a Xenon lamp and filter wheel, composed of an optical output control through Iris and filters with several wavelength bands. It also makes the inducement of auto-fluorescence possible because it is designed to generate a wavelength band of 380-420nm, 430-480nm, and 480-560nm. The transmission part of the light source was developed to enhance the efficiency of light transmission. To evaluate this light source, the characteristics of light output and wavelength band were verified. To validate the capability of this device as PDD, the detection of auto-fluorescence using mouse models was performed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Joyce Jihyun; Schetrit, Oren; Yin, Rongxin
Demand response (DR) – allowing customers to respond to reliability requests and market prices by changing electricity use from their normal consumption pattern – continues to be seen as an attractive means of demand-side management and a fundamental smart-grid improvement that links supply and demand. From October 2011 to December 2013, the Demand Response Research Center at Lawrence Berkeley National Laboratory, the New York State Energy Research and Development Authority, and partners Honeywell and Akuacom, have conducted a demonstration project enabling Automated Demand Response (Auto-DR) in large commercial buildings located in New York City using Open Automated Demand Response (OpenADR)more » communication protocols. In particular, this project focuses on demonstrating how the OpenADR platform, enabled by Akuacom, can automate and simplify interactions between buildings and various stakeholders in New York State and enable the automation of customers’ price response to yield bill savings under dynamic pricing. In this paper, the cost control opportunities under day-ahead hourly pricing and Auto-DR control strategies are presented for four demonstration buildings; present the breakdown of Auto-DR enablement costs; summarize the field test results and their load impact; and show potential bill savings by enabling automated price response under Consolidated Edison’s Mandatory Hourly Pricing (MHP) tariff. For one of the sites, the potential bill savings at the site’s current retail rate are shown. Facility managers were given granular equipment-level opt-out capability to ensure full control of the sites during the Auto-DR implementation. The expected bill savings ranged from 1.1% to 8.0% of the total MHP bill. The automation and enablement costs ranged from $70 to $725 per kW shed. The results show that OpenADR can facilitate the automation of price response, deliver savings to the customers and opt-out capability of the implementation retains control of the sites by facility managers.« less
40 CFR 52.1870 - Identification of plan.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 20, 1972, by the Ohio Air Pollution Control Board. (2) State provisions for making emissions data... authority for controlling auto emissions. (4) Amendments to air pollution regulations AP-3-11, 12, 13, 14... rules establish general provisions for the control of air pollution and were previously codified and...
Optical control of antibacterial activity
NASA Astrophysics Data System (ADS)
Velema, Willem A.; van der Berg, Jan Pieter; Hansen, Mickel J.; Szymanski, Wiktor; Driessen, Arnold J. M.; Feringa, Ben L.
2013-11-01
Bacterial resistance is a major problem in the modern world, stemming in part from the build-up of antibiotics in the environment. Novel molecular approaches that enable an externally triggered increase in antibiotic activity with high spatiotemporal resolution and auto-inactivation are highly desirable. Here we report a responsive, broad-spectrum, antibacterial agent that can be temporally activated with light, whereupon it auto-inactivates on the scale of hours. The use of such a ‘smart’ antibiotic might prevent the build-up of active antimicrobial material in the environment. Reversible optical control over active drug concentration enables us to obtain pharmacodynamic information. Precisely localized control of activity is achieved, allowing the growth of bacteria to be confined to defined patterns, which has potential for the development of treatments that avoid interference with the endogenous microbial population in other parts of the organism.
Niewold, Timothy B; Kelly, Jennifer A; Kariuki, Silvia N; Franek, Beverly S; Kumar, Akaash A; Kaufman, Kenneth M; Thomas, Kenaz; Walker, Daniel; Kamp, Stan; Frost, Jacqueline M; Wong, Andrew K; Merrill, Joan T; Alarcón-Riquelme, Marta E; Tikly, Mohammed; Ramsey-Goldman, Rosalind; Reveille, John D; Petri, Michelle A; Edberg, Jeffrey C; Kimberly, Robert P; Alarcón, Graciela S; Kamen, Diane L; Gilkeson, Gary S; Vyse, Timothy J; James, Judith A; Gaffney, Patrick M; Moser, Kathy L; Crow, Mary K; Harley, John B
2012-01-01
Objective High serum interferon α (IFNα) activity is a heritable risk factor for systemic lupus erythematosus (SLE). Auto-antibodies found in SLE form immune complexes which can stimulate IFNα production by activating endosomal Toll-like receptors and interferon regulatory factors (IRFs), including IRF5. Genetic variation in IRF5 is associated with SLE susceptibility; however, it is unclear how IRF5 functional genetic elements contribute to human disease. Methods 1034 patients with SLE and 989 controls of European ancestry, 555 patients with SLE and 679 controls of African–American ancestry, and 73 patients with SLE of South African ancestry were genotyped at IRF5 polymorphisms, which define major haplotypes. Serum IFNα activity was measured using a functional assay. Results In European ancestry subjects, anti-double-stranded DNA (dsDNA) and anti-Ro antibodies were each associated with different haplotypes characterised by a different combination of functional genetic elements (OR > 2.56, p >003C; 1.9×10−14 for both). These IRF5 haplotype-auto-antibody associations strongly predicted higher serum IFNα in patients with SLE and explained > 70% of the genetic risk of SLE due to IRF5. In African–American patients with SLE a similar relationship between serology and IFNα was observed, although the previously described European ancestry-risk haplotype was present at admixture proportions in African–American subjects and absent in African patients with SLE. Conclusions The authors define a novel risk haplotype of IRF5 that is associated with anti-dsDNA antibodies and show that risk of SLE due to IRF5 genotype is largely dependent upon particular auto-antibodies. This suggests that auto-antibodies are directly pathogenic in human SLE, resulting in increased IFNα in cooperation with particular combinations of IRF5 functional genetic elements. SLE is a systemic autoimmune disorder affecting multiple organ systems including the skin, musculoskeletal, renal and haematopoietic systems. Humoral autoimmunity is a hallmark of SLE, and patients frequently have circulating auto-antibodies directed against dsDNA, as well as RNA binding proteins (RBP). Anti-RBP autoantibodies include antibodies which recognize Ro, La, Smith (anti-Sm), and ribonucleoprotein (anti-nRNP), collectively referred to as anti-retinol-binding protein). Anti-retinol-binding protein and anti-dsDNA auto-antibodies are rare in the healthy population.1 These auto-antibodies can be present in sera for years preceding the onset of clinical SLE illness2 and are likely pathogenic in SLE.34 PMID:22088620
Dynamics of heat shock protein 60 in endothelial cells exposed to cigarette smoke extract
Kreutmayer, Simone Barbara; Messner, Barbara; Knoflach, Michael; Henderson, Blair; Niederegger, Harald; Böck, Günther; Van der Zee, Ruurd; Wick, Georg; Bernhard, David
2011-01-01
Heat shock protein 60 (HSP60), expressed on the surface of endothelial cells (ECs) stressed by e.g. oxidized LDL or mechanical shear, was shown to function as an auto-antigen and thus as a pro-atherosclerotic molecule. The aim of this study was to determine whether cigarette smoke chemicals can lead to the activation of the “HSP60 pathway.” It was also our aim to elucidate the dynamics of HSP60 from gene expression to endothelial surface expression and secretion. Here we show for the first time that the exposure of human umbilical vein endothelial cells (HUVECs) to cigarette smoke extract (CSE) results in an up-regulation of HSP60 mRNA. Live cell imaging analysis of a HSP60-EYFP fusion protein construct transfected into ECs revealed that mitochondrial structures collapse in response to CSE exposure. As a result, HSP60 is released from the mitochondria, transported to the cell surface, and released into the cell culture supernatant. Analysis of HSP60 in the sera of healthy young individuals exposed to secondhand smoke revealed significantly elevated levels of HSP60. Cigarette smoking is one of the most relevant risk factors for atherosclerosis. Herein, we provide evidence that cigarette smoke may initiate atherosclerosis in the sense of the “auto-immune hypothesis of atherosclerosis.” PMID:21798264
Dynamics of heat shock protein 60 in endothelial cells exposed to cigarette smoke extract.
Kreutmayer, Simone Barbara; Messner, Barbara; Knoflach, Michael; Henderson, Blair; Niederegger, Harald; Böck, Günther; Van der Zee, Ruurd; Wick, Georg; Bernhard, David
2011-11-01
Heat shock protein 60 (HSP60), expressed on the surface of endothelial cells (ECs) stressed by e.g. oxidized LDL or mechanical shear, was shown to function as an auto-antigen and thus as a pro-atherosclerotic molecule. The aim of this study was to determine whether cigarette smoke chemicals can lead to the activation of the "HSP60 pathway." It was also our aim to elucidate the dynamics of HSP60 from gene expression to endothelial surface expression and secretion. Here we show for the first time that the exposure of human umbilical vein endothelial cells (HUVECs) to cigarette smoke extract (CSE) results in an up-regulation of HSP60 mRNA. Live cell imaging analysis of a HSP60-EYFP fusion protein construct transfected into ECs revealed that mitochondrial structures collapse in response to CSE exposure. As a result, HSP60 is released from the mitochondria, transported to the cell surface, and released into the cell culture supernatant. Analysis of HSP60 in the sera of healthy young individuals exposed to secondhand smoke revealed significantly elevated levels of HSP60. Cigarette smoking is one of the most relevant risk factors for atherosclerosis. Herein, we provide evidence that cigarette smoke may initiate atherosclerosis in the sense of the "auto-immune hypothesis of atherosclerosis." Copyright © 2011 Elsevier Ltd. All rights reserved.
Autonomous Navigation Performance During The Hartley 2 Comet Flyby
NASA Technical Reports Server (NTRS)
Abrahamson, Matthew J; Kennedy, Brian A.; Bhaskaran, Shyam
2012-01-01
On November 4, 2010, the EPOXI spacecraft performed a 700-km flyby of the comet Hartley 2 as follow-on to the successful 2005 Deep Impact prime mission. EPOXI, an extended mission for the Deep Impact Flyby spacecraft, returned a wealth of visual and infrared data from Hartley 2, marking the fifth time that high-resolution images of a cometary nucleus have been captured by a spacecraft. The highest resolution science return, captured at closest approach to the comet nucleus, was enabled by use of an onboard autonomous navigation system called AutoNav. AutoNav estimates the comet-relative spacecraft trajectory using optical measurements from the Medium Resolution Imager (MRI) and provides this relative position information to the Attitude Determination and Control System (ADCS) for maintaining instrument pointing on the comet. For the EPOXI mission, AutoNav was tasked to enable continuous tracking of a smaller, more active Hartley 2, as compared to Tempel 1, through the full encounter while traveling at a higher velocity. To meet the mission goal of capturing the comet in all MRI science images, position knowledge accuracies of +/- 3.5 km (3-?) cross track and +/- 0.3 seconds (3-?) time of flight were required. A flight-code-in-the-loop Monte Carlo simulation assessed AutoNav's statistical performance under the Hartley 2 flyby dynamics and determined optimal configuration. The AutoNav performance at Hartley 2 was successful, capturing the comet in all of the MRI images. The maximum residual between observed and predicted comet locations was 20 MRI pixels, primarily influenced by the center of brightness offset from the center of mass in the observations and attitude knowledge errors. This paper discusses the Monte Carlo-based analysis that led to the final AutoNav configuration and a comparison of the predicted performance with the flyby performance.
NASA Technical Reports Server (NTRS)
Togai, Masaki
1990-01-01
Viewgraphs on commercial applications of fuzzy logic in Japan are presented. Topics covered include: suitable application area of fuzzy theory; characteristics of fuzzy control; fuzzy closed-loop controller; Mitsubishi heavy air conditioner; predictive fuzzy control; the Sendai subway system; automatic transmission; fuzzy logic-based command system for antilock braking system; fuzzy feed-forward controller; and fuzzy auto-tuning system.
Bellani, Giacomo; Coppadoro, Andrea; Patroniti, Nicolò; Turella, Marta; Arrigoni Marocco, Stefano; Grasselli, Giacomo; Mauri, Tommaso; Pesenti, Antonio
2014-09-01
Auto-positive end-expiratory pressure (auto-PEEP) may substantially increase the inspiratory effort during assisted mechanical ventilation. Purpose of this study was to assess whether the electrical activity of the diaphragm (EAdi) signal can be reliably used to estimate auto-PEEP in patients undergoing pressure support ventilation and neurally adjusted ventilatory assist (NAVA) and whether NAVA was beneficial in comparison with pressure support ventilation in patients affected by auto-PEEP. In 10 patients with a clinical suspicion of auto-PEEP, the authors simultaneously recorded EAdi, airway, esophageal pressure, and flow during pressure support and NAVA, whereas external PEEP was increased from 2 to 14 cm H2O. Tracings were analyzed to measure apparent "dynamic" auto-PEEP (decrease in esophageal pressure to generate inspiratory flow), auto-EAdi (EAdi value at the onset of inspiratory flow), and IDEAdi (inspiratory delay between the onset of EAdi and the inspiratory flow). The pressure necessary to overcome auto-PEEP, auto-EAdi, and IDEAdi was significantly lower in NAVA as compared with pressure support ventilation, decreased with increase in external PEEP, although the effect of external PEEP was less pronounced in NAVA. Both auto-EAdi and IDEAdi were tightly correlated with auto-PEEP (r = 0.94 and r = 0.75, respectively). In the presence of auto-PEEP at lower external PEEP levels, NAVA was characterized by a characteristic shape of the airway pressure. In patients with auto-PEEP, NAVA, compared with pressure support ventilation, led to a decrease in the pressure necessary to overcome auto-PEEP, which could be reliably monitored by the electrical activity of the diaphragm before inspiratory flow onset (auto-EAdi).
2016-05-13
System (MTADS) has a day TV capability to laser designate and auto track tank-sized targets at 6,000 meters and a Forward Looking Infrared (FLIR...capability to laser designate and auto track tank-sized targets at 3,500 meters. The AH-64 D/E also possesses a Fire Control Radar (FCR) that allows it...a broad spectrum of size, capacity, duration, and security. At the low end are Forward Area Refueling Equipment ( FARE ) systems. These allow CH-47
Makarov, O.; Hilgart, M.; Ogata, C.; Pothineni, S.; Cork, C.
2011-01-01
GM/CA CAT at Sector 23 of the Advanced Photon Source (APS) is an NIH funded facility for crystallographic structure determination of biological macromolecules by X-ray diffraction. A second generation Berkeley automounter is being integrated into the beamline control system at the 23-BM experimental station. This new device replaces the previous all-pneumatic gripper motions with a combination of pneumatics and XYZ motorized linear stages. The latter adds a higher degree of flexibility to the robot including auto-alignment capability, accommodation of a larger capacity sample Dewar of arbitrary shape, and support for advanced operations such as crystal washing, while preserving the overall simplicity and efficiency of the Berkeley automounter design. PMID:21822343
Sandia Advanced MEMS Design Tools, Version 2.2.5
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yarberry, Victor; Allen, James; Lantz, Jeffery
2010-01-19
The Sandia National Laboratories Advanced MEMS Design Tools, Version 2.2.5, is a collection of menus, prototype drawings, and executables that provide significant productivity enhancements when using AutoCAD to design MEMS components. This release is designed for AutoCAD 2000i, 2002, or 2004 and is supported under Windows NT 4.0, Windows 2000, or XP. SUMMiT V (Sandia Ultra planar Multi level MEMS Technology) is a 5 level surface micromachine fabrication technology, which customers internal and external to Sandia can access to fabricate prototype MEMS devices. This CD contains an integrated set of electronic files that: a) Describe the SUMMiT V fabrication processmore » b) Facilitate the process of designing MEMS with the SUMMiT process (prototype file, Design Rule Checker, Standard Parts Library) New features in this version: AutoCAD 2004 support has been added. SafeExplode ? a new feature that explodes blocks without affecting polylines (avoids exploding polylines into objects that are ignored by the DRC and Visualization tools). Layer control menu ? a pull-down menu for selecting layers to isolate, freeze, or thaw. Updated tools: A check has been added to catch invalid block names. DRC features: Added username/password validation, added a method to update the user?s password. SNL_DRC_WIDTH ? a value to control the width of the DRC error lines. SNL_BIAS_VALUE ? a value use to offset selected geometry SNL_PROCESS_NAME ? a value to specify the process name Documentation changes: The documentation has been updated to include the new features. While there exist some files on the CD that are used in conjunction with software package AutoCAD, these files are not intended for use independent of the CD. Note that the customer must purchase his/her own copy of AutoCAD to use with these files.« less
Siloşi, Isabela; Boldeanu, Lidia; Biciuşcă, Viorel; Bogdan, Maria; Avramescu, Carmen; Taisescu, Citto; Padureanu, Vlad; Boldeanu, Mihail Virgil; Dricu, Anica; Siloşi, Cristian Adrian
2017-06-19
In the present study, we aimed to estimate the concentrations of cytokines (interleukin 6, IL-6, tumor necrosis factor-α, TNF-α) and auto-antibodies (rheumatoid factor IgM isotype, IgM-RF, antinuclear auto-antibodies, ANA, anti-cyclic citrullinated peptide antibodies IgG isotype, IgG anti-CCP3.1, anti-cardiolipin IgG isotype, IgG anti-aCL) in serum of patients with eRA (early rheumatoid arthritis) and HCVrA (hepatitis C virus-related arthropathy) and to assess the utility of IL-6, TNF-α together with IgG anti-CCP and IgM-RF in distinguishing between patients with true eRA and HCVrA, in the idea of using them as differential immunomarkers. Serum samples were collected from 54 patients (30 diagnosed with eRA-subgroup 1 and 24 with HCVrA-subgroup 2) and from 28 healthy control persons. For the evaluation of serum concentrations of studied cytokines and auto-antibodies, we used immunoenzimatique techniques. The serum concentrations of both proinflammatory cytokines were statistically significantly higher in patients of subgroup 1 and subgroup 2, compared to the control group ( p < 0.0001). Our study showed statistically significant differences of the mean concentrations only for ANA and IgG anti-CCP between subgroup 1 and subgroup 2. We also observed that IL-6 and TNF-α better correlated with auto-antibodies in subgroup 1 than in subgroup 2. In both subgroups of patients, ROC curves indicated that IL-6 and TNF-α have a higher diagnostic utility as markers of disease. In conclusion, we can say that, due to high sensitivity for diagnostic accuracy, determination of serum concentrations of IL-6 and TNF-α, possibly in combination with auto-antibodies, could be useful in the diagnosis and distinguishing between patients with true eRA and HCV patients with articular manifestation and may prove useful in the monitoring of the disease course.
40 CFR 52.1870 - Identification of plan.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 20, 1972, by the Ohio Air Pollution Control Board. (2) State provisions for making emissions data... authority for controlling auto emissions. (4) Amendments to air pollution regulations AP-3-11, 12, 13, 14... the control of air pollution and were previously codified and approved as AP-2-01 through 06, 08 and...
49 CFR Appendix E to Part 236 - Human-Machine Interface (HMI) Design
Code of Federal Regulations, 2013 CFR
2013-10-01
... operator to change position; (4) Arrange controls according to their expected order of use; (5) Group similar controls together; (6) Design for high stimulus-response compatibility (geometric and conceptual); (7) Design safety-critical controls to require more than one positive action to activate (e.g., auto...
49 CFR Appendix E to Part 236 - Human-Machine Interface (HMI) Design
Code of Federal Regulations, 2010 CFR
2010-10-01
... operator to change position; (4) Arrange controls according to their expected order of use; (5) Group similar controls together; (6) Design for high stimulus-response compatibility (geometric and conceptual); (7) Design safety-critical controls to require more than one positive action to activate (e.g., auto...
49 CFR Appendix E to Part 236 - Human-Machine Interface (HMI) Design
Code of Federal Regulations, 2014 CFR
2014-10-01
... operator to change position; (4) Arrange controls according to their expected order of use; (5) Group similar controls together; (6) Design for high stimulus-response compatibility (geometric and conceptual); (7) Design safety-critical controls to require more than one positive action to activate (e.g., auto...
49 CFR Appendix E to Part 236 - Human-Machine Interface (HMI) Design
Code of Federal Regulations, 2011 CFR
2011-10-01
... operator to change position; (4) Arrange controls according to their expected order of use; (5) Group similar controls together; (6) Design for high stimulus-response compatibility (geometric and conceptual); (7) Design safety-critical controls to require more than one positive action to activate (e.g., auto...
49 CFR Appendix E to Part 236 - Human-Machine Interface (HMI) Design
Code of Federal Regulations, 2012 CFR
2012-10-01
... operator to change position; (4) Arrange controls according to their expected order of use; (5) Group similar controls together; (6) Design for high stimulus-response compatibility (geometric and conceptual); (7) Design safety-critical controls to require more than one positive action to activate (e.g., auto...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-02
... Guidelines in Lieu of Regulations for Miscellaneous Metal Products Coatings, Plastic Parts Coatings, Auto and... Pleasure Craft portion of the Control Techniques Guidelines (CTG) for Miscellaneous Metal and Plastic Parts... and Plastic Parts Coatings regulations based on EPA's 2008 guidance titled ``Control Techniques...
Environmental exposure to benzene: an update.
Wallace, L
1996-01-01
During the 1990s, several large-scale studies of benzene concentrations in air, food, and blood have added to our knowledge of its environmental occurrence. In general, the new studies have confirmed the earlier findings of the U.S. Environmental Protection Agency Total Exposure Assessment Methodology (TEAM) studies and other large-scale studies in Germany and the Netherlands concerning the levels of exposure and major sources. For example, the new studies found that personal exposures exceeded indoor concentrations of benzene, which in turn exceeded outdoor concentrations. The new studies of food concentrations have confirmed earlier indications that food is not an important pathway for benzene exposure. The results of the National Health and Nutrition Examination Survey on blood levels in a nationwide sample of 883 persons are in good agreement with the concentrations in exhaled breath measured in about 800 persons a decade earlier in the TEAM studies. Major sources of exposure continue to be active and passive smoking, auto exhaust, and driving or riding in automobiles. New methods in breath and blood sampling and analysis offer opportunities to investigate short-term peak exposures and resulting body burden under almost any conceivable field conditions. PMID:9118882
Myocarditis in auto-immune or auto-inflammatory diseases.
Comarmond, Cloé; Cacoub, Patrice
2017-08-01
Myocarditis is a major cause of heart disease in young patients and a common precursor of heart failure due to dilated cardiomyopathy. Some auto-immune and/or auto-inflammatory diseases may be accompanied by myocarditis, such as sarcoidosis, Behçet's disease, eosinophilic granulomatosis with polyangiitis, myositis, and systemic lupus erythematosus. However, data concerning myocarditis in such auto-immune and/or auto-inflammatory diseases are sparse. New therapeutic strategies should better target the modulation of the immune system, depending on the phase of the disease and the type of underlying auto-immune and/or auto-inflammatory disease. Copyright © 2017 Elsevier B.V. All rights reserved.
Space imaging infrared optical guidance for autonomous ground vehicle
NASA Astrophysics Data System (ADS)
Akiyama, Akira; Kobayashi, Nobuaki; Mutoh, Eiichiro; Kumagai, Hideo; Yamada, Hirofumi; Ishii, Hiromitsu
2008-08-01
We have developed the Space Imaging Infrared Optical Guidance for Autonomous Ground Vehicle based on the uncooled infrared camera and focusing technique to detect the objects to be evaded and to set the drive path. For this purpose we made servomotor drive system to control the focus function of the infrared camera lens. To determine the best focus position we use the auto focus image processing of Daubechies wavelet transform technique with 4 terms. From the determined best focus position we transformed it to the distance of the object. We made the aluminum frame ground vehicle to mount the auto focus infrared unit. Its size is 900mm long and 800mm wide. This vehicle mounted Ackerman front steering system and the rear motor drive system. To confirm the guidance ability of the Space Imaging Infrared Optical Guidance for Autonomous Ground Vehicle we had the experiments for the detection ability of the infrared auto focus unit to the actual car on the road and the roadside wall. As a result the auto focus image processing based on the Daubechies wavelet transform technique detects the best focus image clearly and give the depth of the object from the infrared camera unit.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swarin, S.J.; Loo, J.F.; Chladek, E.
1992-01-01
Analytical methods for determining individual aldehyde, ketone, and alcohol emissions from gasoline-, methanol-, and variable-fueled vehicles are described. These methods were used in the Auto/Oil Air Quality Improvement Research Program to provide emission data for comparison of individual reformulated fuels, individual vehicles, and for air modeling studies. The emission samples are collected in impingers which contain either 2,4-dinitrophenylhydrazine solution for the aldehydes and ketones or deionized water for the alcohols. Subsequent analyses by liquid chromatography for the aldehydes and ketones and gas chromatography for the alcohols utilized auto injectors and computerized data systems which permit high sample throughput with minimalmore » operator intervention. The quality control procedures developed and interlaboratory comparisons conducted as part of the program are also described. (Copyright (c) 1992 Society of Automotive Engineers, Inc.)« less
TH-AB-202-04: Auto-Adaptive Margin Generation for MLC-Tracked Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glitzner, M; Lagendijk, J; Raaymakers, B
Purpose: To develop an auto-adaptive margin generator for MLC tracking. The generator is able to estimate errors arising in image guided radiotherapy, particularly on an MR-Linac, which depend on the latencies of machine and image processing, as well as on patient motion characteristics. From the estimated error distribution, a segment margin is generated, able to compensate errors up to a user-defined confidence. Method: In every tracking control cycle (TCC, 40ms), the desired aperture D(t) is compared to the actual aperture A(t), a delayed and imperfect representation of D(t). Thus an error e(t)=A(T)-D(T) is measured every TCC. Applying kernel-density-estimation (KDE), themore » cumulative distribution (CDF) of e(t) is estimated. With CDF-confidence limits, upper and lower error limits are extracted for motion axes along and perpendicular leaf-travel direction and applied as margins. To test the dosimetric impact, two representative motion traces were extracted from fast liver-MRI (10Hz). The traces were applied onto a 4D-motion platform and continuously tracked by an Elekta Agility 160 MLC using an artificially imposed tracking delay. Gafchromic film was used to detect dose exposition for static, tracked, and error-compensated tracking cases. The margin generator was parameterized to cover 90% of all tracking errors. Dosimetric impact was rated by calculating the ratio between underexposed points (>5% underdosage) to the total number of points inside FWHM of static exposure. Results: Without imposing adaptive margins, tracking experiments showed a ratio of underexposed points of 17.5% and 14.3% for two motion cases with imaging delays of 200ms and 300ms, respectively. Activating the margin generated yielded total suppression (<1%) of underdosed points. Conclusion: We showed that auto-adaptive error compensation using machine error statistics is possible for MLC tracking. The error compensation margins are calculated on-line, without the need of assuming motion or machine models. Further strategies to reduce consequential overdosages are currently under investigation. This work was funded by the SoRTS consortium, which includes the industry partners Elekta, Philips and Technolution.« less
Surface treatment of dental porcelain: CO2 laser as an alternative to oven glaze.
Sgura, Ricardo; Reis, Mariana Cavalcante; Hernandes, Antonio Carlos; de Abreu Fantini, Márcia Carvalho; Andreeta, Marcello Rubens Barsi; Medeiros, Igor Studart
2015-02-01
This work tested continuous CO2 laser as a surface treatment to dental porcelain and compared it to oven glaze (auto-glaze) by means of roughness and color parameters. Three commercial veneering porcelains with different crystalline content were tested: VM7, VM9, and VM13. Porcelain discs (3.5 × 2.0 mm, diameter × height) were sintered and had one side ground by a diamond bur (45 μm) simulating a chairside adjustment in a clinical office. Specimens (n = 7) were divided into the following groups: C--control (no treatment), G--auto-glaze (oven), and L--surface continuous irradiation with CO2 laser (Gem Laser, Coherent; λ = 10.6 μm). Laser was tested in three exposure times (3, 4, or 5 min) and two irradiances (45 and 50 W/cm(2)). Roughness parameters (Ra, Rz, and Rpm/Rz) were measured using a rugosimeter (Surftest 301, Mitutoyo). Color differences (ΔE) between the G and L groups were calculated (VITA Easyshade); ΔE values up to 3.3 were considered as not perceivable. A surface analysis was conducted by stereomicroscopy (Olympus SZ61) and SEM (Stereoscan 440, LEO). Crystalline content of specimens from groups C and L (50 W/cm(2), 5 min) was assessed by X-ray diffraction and then compared. Surface roughness (Ra and Rz) observed for laser-irradiated groups was similar to G for all studied porcelains. Rpm/Rz ratios were near 1.0 for all groups that indicated a sharp ridge profile for all specimens. Only one laser condition studied (50 W/cm(2), 3 min) from VM7 porcelain resulted in color difference (ΔE = 3.5) to G. Specimens irradiated with 50 W/cm(2) for 5 min presented the smoother surface observed by SEM, comparable to G. X-ray diffraction data revealed an increase in leucite crystallite size for VM9 and VM13 porcelains after laser treatment. Regarding roughness, continuous CO2 laser applied on porcelain surface was as effective as conventional oven auto-glaze.
Integrated G and C Implementation within IDOS: A Simulink Based Reusable Launch Vehicle Simulation
NASA Technical Reports Server (NTRS)
Fisher, Joseph E.; Bevacqua, Tim; Lawrence, Douglas A.; Zhu, J. Jim; Mahoney, Michael
2003-01-01
The implementation of multiple Integrated Guidance and Control (IG&C) algorithms per flight phase within a vehicle simulation poses a daunting task to coordinate algorithm interactions with the other G&C components and with vehicle subsystems. Currently being developed by Universal Space Lines LLC (USL) under contract from NASA, the Integrated Development and Operations System (IDOS) contains a high fidelity Simulink vehicle simulation, which provides a means to test cutting edge G&C technologies. Combining the modularity of this vehicle simulation and Simulink s built-in primitive blocks provide a quick way to implement algorithms. To add discrete-event functionality to the unfinished IDOS simulation, Vehicle Event Manager (VEM) and Integrated Vehicle Health Monitoring (IVHM) subsystems were created to provide discrete-event and pseudo-health monitoring processing capabilities. Matlab's Stateflow is used to create the IVHM and Event Manager subsystems and to implement a supervisory logic controller referred to as the Auto-commander as part of the IG&C to coordinate the control system adaptation and reconfiguration and to select the control and guidance algorithms for a given flight phase. Manual creation of the Stateflow charts for all of these subsystems is a tedious and time-consuming process. The Stateflow Auto-builder was developed as a Matlab based software tool for the automatic generation of a Stateflow chart from information contained in a database. This paper describes the IG&C, VEM and IVHM implementations in IDOS. In addition, this paper describes the Stateflow Auto-builder.
The constellation of dietary factors in adolescent acne: a semantic connectivity map approach.
Grossi, E; Cazzaniga, S; Crotti, S; Naldi, L; Di Landro, A; Ingordo, V; Cusano, F; Atzori, L; Tripodi Cutrì, F; Musumeci, M L; Pezzarossa, E; Bettoli, V; Caproni, M; Bonci, A
2016-01-01
Different lifestyle and dietetic factors have been linked with the onset and severity of acne. To assess the complex interconnection between dietetic variables and acne. This was a reanalysis of data from a case-control study by using a semantic connectivity map approach. 563 subjects, aged 10-24 years, involved in a case-control study of acne between March 2009 and February 2010, were considered in this study. The analysis evaluated the link between a moderate to severe acne and anthropometric variables, family history and dietetic factors. Analyses were conducted by relying on an artificial adaptive system, the Auto Semantic Connectivity Map (AutoCM). The AutoCM map showed that moderate-severe acne was closely associated with family history of acne in first degree relatives, obesity (BMI ≥ 30), and high consumption of milk, in particular skim milk, cheese/yogurt, sweets/cakes, chocolate, and a low consumption of fish, and limited intake of fruits/vegetables. Our analyses confirm the link between several dietetic items and acne. When providing care, dermatologists should also be aware of the complex interconnection between dietetic factors and acne. © 2014 European Academy of Dermatology and Venereology.
Prototype of an auto-calibrating, context-aware, hybrid brain-computer interface.
Faller, J; Torrellas, S; Miralles, F; Holzner, C; Kapeller, C; Guger, C; Bund, J; Müller-Putz, G R; Scherer, R
2012-01-01
We present the prototype of a context-aware framework that allows users to control smart home devices and to access internet services via a Hybrid BCI system of an auto-calibrating sensorimotor rhythm (SMR) based BCI and another assistive device (Integra Mouse mouth joystick). While there is extensive literature that describes the merit of Hybrid BCIs, auto-calibrating and co-adaptive ERD BCI training paradigms, specialized BCI user interfaces, context-awareness and smart home control, there is up to now, no system that includes all these concepts in one integrated easy-to-use framework that can truly benefit individuals with severe functional disabilities by increasing independence and social inclusion. Here we integrate all these technologies in a prototype framework that does not require expert knowledge or excess time for calibration. In a first pilot-study, 3 healthy volunteers successfully operated the system using input signals from an ERD BCI and an Integra Mouse and reached average positive predictive values (PPV) of 72 and 98% respectively. Based on what we learned here we are planning to improve the system for a test with a larger number of healthy volunteers so we can soon bring the system to benefit individuals with severe functional disability.
Testing First-Order Logic Axioms in AutoCert
NASA Technical Reports Server (NTRS)
Ahn, Ki Yung; Denney, Ewen
2009-01-01
AutoCert [2] is a formal verification tool for machine generated code in safety critical domains, such as aerospace control code generated from MathWorks Real-Time Workshop. AutoCert uses Automated Theorem Provers (ATPs) [5] based on First-Order Logic (FOL) to formally verify safety and functional correctness properties of the code. These ATPs try to build proofs based on user provided domain-specific axioms, which can be arbitrary First-Order Formulas (FOFs). These axioms are the most crucial part of the trusted base, since proofs can be submitted to a proof checker removing the need to trust the prover and AutoCert itself plays the part of checking the code generator. However, formulating axioms correctly (i.e. precisely as the user had really intended) is non-trivial in practice. The challenge of axiomatization arise from several dimensions. First, the domain knowledge has its own complexity. AutoCert has been used to verify mathematical requirements on navigation software that carries out various geometric coordinate transformations involving matrices and quaternions. Axiomatic theories for such constructs are complex enough that mistakes are not uncommon. Second, adjusting axioms for ATPs can add even more complexity. The axioms frequently need to be modified in order to have them in a form suitable for use with ATPs. Such modifications tend to obscure the axioms further. Thirdly, speculating validity of the axioms from the output of existing ATPs is very hard since theorem provers typically do not give any examples or counterexamples.
V-TECS Guide for Automobile Engine Performance Technician.
ERIC Educational Resources Information Center
Meyer, Calvin F.; Benson, Robert T.
This guide is intended to assist teachers responsible for instructing future auto engine performance technicians. The following topics are covered: diagnosing engine performance problems, ignition system problems, fuel system problems, mechanically related performance problems, emission control system problems, and electronic control systems;…
Yu, Lijing; Zhou, Lingling; Tan, Li; Jiang, Hongbo; Wang, Ying; Wei, Sheng; Nie, Shaofa
2014-01-01
Outbreaks of hand-foot-mouth disease (HFMD) have been reported for many times in Asia during the last decades. This emerging disease has drawn worldwide attention and vigilance. Nowadays, the prevention and control of HFMD has become an imperative issue in China. Early detection and response will be helpful before it happening, using modern information technology during the epidemic. In this paper, a hybrid model combining seasonal auto-regressive integrated moving average (ARIMA) model and nonlinear auto-regressive neural network (NARNN) is proposed to predict the expected incidence cases from December 2012 to May 2013, using the retrospective observations obtained from China Information System for Disease Control and Prevention from January 2008 to November 2012. The best-fitted hybrid model was combined with seasonal ARIMA [Formula: see text] and NARNN with 15 hidden units and 5 delays. The hybrid model makes the good forecasting performance and estimates the expected incidence cases from December 2012 to May 2013, which are respectively -965.03, -1879.58, 4138.26, 1858.17, 4061.86 and 6163.16 with an obviously increasing trend. The model proposed in this paper can predict the incidence trend of HFMD effectively, which could be helpful to policy makers. The usefulness of expected cases of HFMD perform not only in detecting outbreaks or providing probability statements, but also in providing decision makers with a probable trend of the variability of future observations that contains both historical and recent information.
Auto-tuning for NMR probe using LabVIEW
NASA Astrophysics Data System (ADS)
Quen, Carmen; Pham, Stephanie; Bernal, Oscar
2014-03-01
Typical manual NMR-tuning method is not suitable for broadband spectra spanning several megahertz linewidths. Among the main problems encountered during manual tuning are pulse-power reproducibility, baselines, and transmission line reflections, to name a few. We present a design of an auto-tuning system using graphic programming language, LabVIEW, to minimize these problems. The program uses a simplified model of the NMR probe conditions near perfect tuning to mimic the tuning process and predict the position of the capacitor shafts needed to achieve the desirable impedance. The tuning capacitors of the probe are controlled by stepper motors through a LabVIEW/computer interface. Our program calculates the effective capacitance needed to tune the probe and provides controlling parameters to advance the motors in the right direction. The impedance reading of a network analyzer can be used to correct the model parameters in real time for feedback control.
2011-01-01
Background Routine exposure to chemical contaminants in workplace is a cause for concern over potential health risks to workers. In Pakistan, reports on occupational exposure and related health risks are almost non-existent, which reflects the scarce availability of survey data and criteria for determining whether an unsafe exposure has occurred. The current study was designed to evaluate blood naphthalene (NAPH) levels as an indicator of exposure to polycyclic aromatic hydrocarbons (PAHs) among automobile workshop mechanics (MCs) and car-spray painters (PNs). We further determined the relationship between blood NAPH levels and personal behavioural, job related parameters and various environmental factors that may further be associated with elevated risks of occupational exposures to PAHs. Methods Sixty blood samples (n = 20 for each group i.e. MC, PN and control group) were collected to compare their blood NAPH levels among exposed (MCs and PNs) and un-exposed (control) groups. Samples were analyzed using high pressure liquid chromatography (HPLC). Data regarding demographic aspects of the subjects and their socioeconomic features were collected using a questionnaire. Subjects were also asked to report environmental hygiene conditions of their occupational environment. Results We identified automobile work areas as potential sites for PAHs exposure, which was reflected by higher blood NAPH levels among MCs. Blood NAPH levels ranged from 53.7 to 1980.6 μgL-1 and 54.1 to 892.9 μgL-1 among MCs and PNs respectively. Comparison within each group showed that smoking enhanced exposure risks several fold and both active and passive smoking were among personal parameters that were significantly correlated with log-transformed blood NAPH levels. For exposed groups, work hours and work experience were job related parameters that showed strong associations with the increase in blood NAPH levels. Poor workplace hygiene and ventilation were recognized as most significant predictors related to differences among workplaces that may enhance the extent of exposure to chemical contaminants. Conclusions It appeared that chemical exposure at the workplace may be influenced by multiple environmental factors, but poor workplace hygiene and duration of exposure (long work hours) were the most important factors. Smoking and negligence of workers regarding self protection were among some of the important personal behaviours than can be addressed with better training. There is also a need to improve workplaces hygiene and to rationalize work hours to minimize health risks. Since smoking was an important confounding factor that supplemented most of the actual occupational exposure, a study based on non-smoker subjects is needed to separate out the effects of smoking and other confounding factors that may obscure measurements of actual extent of occupational exposure. PMID:21668991
Automotive Refinishing Industry: Isocyanates Profile
The isocyanates profile document is part of the DfE Auto Refinishing Shop Project and is intended to provide information on refinishing, control technologies, and regulatory status regarding isocyanate compounds
77 FR 43216 - Denial of Motor Vehicle Defect Petition and Petition for a Hearing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-24
... Tribute vehicles with certain cruise control cables. The Center for Auto Safety has also petitioned for a... cruise) control cable can result if the accelerator cable is not properly removed. Mazda, however, did... cruise) control cables may have been damaged during the accelerator cable replacements conducted in...
Comparisons of fully automated syphilis tests with conventional VDRL and FTA-ABS tests.
Choi, Seung Jun; Park, Yongjung; Lee, Eun Young; Kim, Sinyoung; Kim, Hyon-Suk
2013-06-01
Serologic tests are widely used for the diagnosis of syphilis. However, conventional methods require well-trained technicians to produce reliable results. We compared automated nontreponemal and treponemal tests with conventional methods. The HiSens Auto Rapid Plasma Reagin (AutoRPR) and Treponema Pallidum particle agglutination (AutoTPPA) tests, which utilize latex turbidimetric immunoassay, were assessed. A total of 504 sera were assayed by AutoRPR, AutoTPPA, conventional VDRL and FTA-ABS. Among them, 250 samples were also tested by conventional TPPA. The concordance rate between the results of VDRL and AutoRPR was 67.5%, and 164 discrepant cases were all VDRL reactive but AutoRPR negative. In the 164 cases, 133 showed FTA-ABS reactivity. Medical records of 106 among the 133 cases were reviewed, and 82 among 106 specimens were found to be collected from patients already treated for syphilis. The concordance rate between the results of AutoTPPA and FTA-ABS was 97.8%. The results of conventional TPPA and AutoTPPA for 250 samples were concordant in 241 cases (96.4%). AutoRPR showed higher specificity than that of VDRL, while VDRL demonstrated higher sensitivity than that of AutoRPR regardless of whether the patients had been already treated for syphilis or not. Both FTA-ABS and AutoTPPA showed high sensitivities and specificities greater than 98.0%. Automated RPR and TPPA tests could be alternatives to conventional syphilis tests, and AutoRPR would be particularly suitable in treatment monitoring, since results by AutoRPR in cases after treatment became negative more rapidly than by VDRL. Copyright © 2013. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Gu, L.
2017-12-01
In this study, we examine responses of sun-induced chlorophyll fluorescence to biological and environmental variations measured with a versatile Fluorescence Auto-Measurement Equipment (FAME). FAME was developed to automatically and continuously measure chlorophyll fluorescence (F) of a leaf, plant or canopy in both laboratory and field environments, excited by either artificial light source or sunlight. FAME is controlled by a datalogger and allows simultaneous measurements of environmental variables complementary to the F signals. A built-in communication system allows FAME to be remotely monitored and data-downloaded. Radiance and irradiance calibrations can be done online. FAME has been applied in a variety of environments, allowing an investigation of biological and environmental controls on F emission.
A novel auto-tuning PID control mechanism for nonlinear systems.
Cetin, Meric; Iplikci, Serdar
2015-09-01
In this paper, a novel Runge-Kutta (RK) discretization-based model-predictive auto-tuning proportional-integral-derivative controller (RK-PID) is introduced for the control of continuous-time nonlinear systems. The parameters of the PID controller are tuned using RK model of the system through prediction error-square minimization where the predicted information of tracking error provides an enhanced tuning of the parameters. Based on the model-predictive control (MPC) approach, the proposed mechanism provides necessary PID parameter adaptations while generating additive correction terms to assist the initially inadequate PID controller. Efficiency of the proposed mechanism has been tested on two experimental real-time systems: an unstable single-input single-output (SISO) nonlinear magnetic-levitation system and a nonlinear multi-input multi-output (MIMO) liquid-level system. RK-PID has been compared to standard PID, standard nonlinear MPC (NMPC), RK-MPC and conventional sliding-mode control (SMC) methods in terms of control performance, robustness, computational complexity and design issue. The proposed mechanism exhibits acceptable tuning and control performance with very small steady-state tracking errors, and provides very short settling time for parameter convergence. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.
Photon collider: a four-channel autoguider solution
NASA Astrophysics Data System (ADS)
Hygelund, John C.; Haynes, Rachel; Burleson, Ben; Fulton, Benjamin J.
2010-07-01
The "Photon Collider" uses a compact array of four off axis autoguider cameras positioned with independent filtering and focus. The photon collider is two way symmetric and robustly mounted with the off axis light crossing the science field which allows the compact single frame construction to have extremely small relative deflections between guide and science CCDs. The photon collider provides four independent guiding signals with a total of 15 square arc minutes of sky coverage. These signals allow for simultaneous altitude, azimuth, field rotation and focus guiding. Guide cameras read out without exposure overhead increasing the tracking cadence. The independent focus allows the photon collider to maintain in focus guide stars when the main science camera is taking defocused exposures as well as track for telescope focus changes. Independent filters allow auto guiding in the science camera wavelength bandpass. The four cameras are controlled with a custom web services interface from a single Linux based industrial PC, and the autoguider mechanism and telemetry is built around a uCLinux based Analog Devices BlackFin embedded microprocessor. Off axis light is corrected with a custom meniscus correcting lens. Guide CCDs are cooled with ethylene glycol with an advanced leak detection system. The photon collider was built for use on Las Cumbres Observatory's 2 meter Faulks telescopes and currently used to guide the alt-az mount.
Criterion-Referenced Test Items for Auto Body.
ERIC Educational Resources Information Center
Tannehill, Dana, Ed.
This test item bank on auto body repair contains criterion-referenced test questions based upon competencies found in the Missouri Auto Body Competency Profile. Some test items are keyed for multiple competencies. The tests cover the following 26 competency areas in the auto body curriculum: auto body careers; measuring and mixing; tools and…
NASA Astrophysics Data System (ADS)
Trejo-Núñez, A. D.; Pérez-Chávez, F.; García-Sánchez, C.; Serrano-Luna, G.; Cañendo-Dorantes, L.
2008-08-01
This study was designed to, investigate the healing effects of extremely low frequency electromagnetic fields (ELF-EMF) on diabetic foot ulcers and test two different exposure systems aimed at reducing the ELF-EMF exposure time of patients. In the first system the ELF-EMF were applied to the arm where only 3% of the total blood volume/min circulates at any given time. In the second system the ELF-EMF were applied to the thorax where more than 100% of the total blood volume/minute circulates at any given time. Twenty-six diabetic patients, with superficial neuropathic ulcers unresponsive to medical treatment were included in this preliminary report. In the first group (17 patients), the arm was exposed two hours twice a week to a extremely low frequency electromagnetic field of 0.45-0.9 mTrms, 120 Hz generated inside a solenoid coil of 10.1 cm by 20.5 cm long. In the second group the thorax of 7 patients was exposed 25 minutes twice a week to an electromagnetic field of 0.4-0.85 mTrms, 120 Hz generated in the center of a squared quasi-Helmholtz coil 52 cm by side. One patient was assigned to a placebo configuration of each exposure system with identical appearance as the active equipment but without magnetic field. Patients with deep ulcers, infected ulcers, cancer, or auto-immune disease were excluded. These preliminary results showed that the two exposure systems accelerate the healing process of neuropathic ulcers. Complete healing of the ulcer had a median duration of 90 days in both exposure systems. Therefore thorax exposure where more blood is exposed to ELF-EMF per unit of time was able to reduce 4.8 times the patient treatment time. In those patients assigned to the placebo equipment no healing effects were observed. This study will continue with a parallel, double blind placebo controlled protocol.
[Spleen autotransplant. Natural history and description of a case].
Ceccherini, E; Sereni, P; Ferrari, F; Fagioli Zucchi, A; Croce, F; Di Maggio, G; Vattimo, A; Mancini, S
1989-09-30
After considering the natural history of spleen auto-transplant, a clinical case followed up for seven months with instrumental (echography, scintigraphy) and humoral (Jolly bodies, Heinz bodies, reticulocytes, platelets, complement, immune globulin) examinations has been considered so as to verify "take" and function. One months after reimplantation the patient was again operated on for the onset of an intestinal occlusion due to adherences. On that occasion it was possible to control that the implant had taken. It is concluded that personally used parameters proved to be well correlated and that scintigraphy and echography are two complementary, effective techniques for monitoring auto-transplants.
Operant Conditioning in Honey Bees (Apis mellifera L.): The Cap Pushing Response.
Abramson, Charles I; Dinges, Christopher W; Wells, Harrington
2016-01-01
The honey bee has been an important model organism for studying learning and memory. More recently, the honey bee has become a valuable model to understand perception and cognition. However, the techniques used to explore psychological phenomena in honey bees have been limited to only a few primary methodologies such as the proboscis extension reflex, sting extension reflex, and free flying target discrimination-tasks. Methods to explore operant conditioning in bees and other invertebrates are not as varied as with vertebrates. This may be due to the availability of a suitable response requirement. In this manuscript we offer a new method to explore operant conditioning in honey bees: the cap pushing response (CPR). We used the CPR to test for difference in learning curves between novel auto-shaping and more traditional explicit-shaping. The CPR protocol requires bees to exhibit a novel behavior by pushing a cap to uncover a food source. Using the CPR protocol we tested the effects of both explicit-shaping and auto-shaping techniques on operant conditioning. The goodness of fit and lack of fit of these data to the Rescorla-Wagner learning-curve model, widely used in classical conditioning studies, was tested. The model fit well to both control and explicit-shaping results, but only for a limited number of trials. Learning ceased rather than continuing to asymptotically approach the physiological most accurate possible. Rate of learning differed between shaped and control bee treatments. Learning rate was about 3 times faster for shaped bees, but for all measures of proficiency control and shaped bees reached the same level. Auto-shaped bees showed one-trial learning rather than the asymptotic approach to a maximal efficiency. However, in terms of return-time, the auto-shaped bees' learning did not carry over to the covered-well test treatments.
Operant Conditioning in Honey Bees (Apis mellifera L.): The Cap Pushing Response
Abramson, Charles I.; Dinges, Christopher W.; Wells, Harrington
2016-01-01
The honey bee has been an important model organism for studying learning and memory. More recently, the honey bee has become a valuable model to understand perception and cognition. However, the techniques used to explore psychological phenomena in honey bees have been limited to only a few primary methodologies such as the proboscis extension reflex, sting extension reflex, and free flying target discrimination-tasks. Methods to explore operant conditioning in bees and other invertebrates are not as varied as with vertebrates. This may be due to the availability of a suitable response requirement. In this manuscript we offer a new method to explore operant conditioning in honey bees: the cap pushing response (CPR). We used the CPR to test for difference in learning curves between novel auto-shaping and more traditional explicit-shaping. The CPR protocol requires bees to exhibit a novel behavior by pushing a cap to uncover a food source. Using the CPR protocol we tested the effects of both explicit-shaping and auto-shaping techniques on operant conditioning. The goodness of fit and lack of fit of these data to the Rescorla-Wagner learning-curve model, widely used in classical conditioning studies, was tested. The model fit well to both control and explicit-shaping results, but only for a limited number of trials. Learning ceased rather than continuing to asymptotically approach the physiological most accurate possible. Rate of learning differed between shaped and control bee treatments. Learning rate was about 3 times faster for shaped bees, but for all measures of proficiency control and shaped bees reached the same level. Auto-shaped bees showed one-trial learning rather than the asymptotic approach to a maximal efficiency. However, in terms of return-time, the auto-shaped bees’ learning did not carry over to the covered-well test treatments. PMID:27626797
Gupta, Manoj Kumar; Jain, Rajeev; Singh, Pratibha; Ch, Ratnasekhar; Mudiam, Mohana Krishna Reddy
2015-06-01
Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous environmental pollutants and well-known carcinogens. Hydroxy derivatives of PAH are considered as biomarkers of PAH exposure, and there is a need to measure these metabolites at low concentrations. So, a precise and eco-friendly analytical method has been developed for rapid determination of PAH metabolites. For the first time, a new analytical method based on coupling of dispersive liquid-liquid microextraction (DLLME) with auto-injector port silylation (auto-IPS) followed by gas chromatography-tandem mass spectrometry (GC-MS-MS) analysis is reported for the analysis of seven urinary PAH metabolites. Factors affecting DLLME and IPS, such as type and volume of extraction and disperser solvent, pH, ionic strength, injector port temperature, volume of N,O-bis(trimethylsilyl)trifluoroacetamide and type of solvent were investigated. Under optimized conditions, the limit of detection and limit of quantification were found to be in the range of 1-9 and 3-29 ng/mL, respectively. Satisfactory recoveries of metabolites in urine samples in the range of 87-95% were found. The developed method has been successfully applied for the determination of PAH metabolites in urine samples of exposed workers. DLLME-auto-IPS-GC-MS-MS method is time, labor, solvent and reagent saving, which can be routinely used for the analysis of urinary PAH metabolites. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Occupational and Lifestyle Determinants of Blood Lead Levels among Men in Madras, India.
Potula; Hu
1996-01-01
The objective of this epidemiologic study was to assess the relationship of blood lead levels to occupational exposure to the combustion products of leaded gasoline and to several lifestyle factors (smoking, alcohol consumption, and diet) among men from four occupational groups in Madras, India. Blood lead was measured using graphite-furnace atomic-absorption spectrophotometry. The mean (SD) blood lead levels in 129 blood samples collected from traffic police, bus drivers, and auto-shop workers were 11.2 (8.8), 12 (11.1), and 17.5 (8.4) µg/dL, respectively; the corresponding value for urban controls (office workers) was 4.1 (2.1) µg/dL. In a final multivariate regression model, a non-vegetarian diet and job category remained the strongest predictors of blood lead level (p < 0.05), while smoking, alcohol consumption, and duration of employment were not significantly correlated with blood lead levels. The authors conclude that continued use of leaded gasoline probably plays a dominant role in determining blood lead levels in Madras.
Automotive Mechanics as Applied to Auto Body; Auto Body Repair and Refinishing 3: 9037.02.
ERIC Educational Resources Information Center
Dade County Public Schools, Miami, FL.
This is a course in which the student will receive the general information, technical knowledge, basic skills, attitudes, and values required for job entry level as an auto body repair helper. Course content includes general and specific goals, orientation, instruction in service tools and bench skills, and auto mechanics as applied to auto body.…
Koodaryan, Roodabeh; Hafezeqoran, Ali
2016-12-01
Polyamide polymers do not provide sufficient bond strength to auto-polymerized resins for repairing fractured denture or replacing dislodged denture teeth. Limited treatment methods have been developed to improve the bond strength between auto-polymerized reline resins and polyamide denture base materials. The objective of the present study was to evaluate the effect of surface modification by acetic acid on surface characteristics and bond strength of reline resin to polyamide denture base. 84 polyamide specimens were divided into three surface treatment groups (n=28): control (N), silica-coated (S), and acid-treated (A). Two different auto-polymerized reline resins GC and Triplex resins were bonded to the samples (subgroups T and G, respectively, n=14). The specimens were subjected to shear bond strength test after they were stored in distilled water for 1 week and thermo-cycled for 5000 cycles. Data were analyzed with independent t-test, two-way analysis of variance (ANOVA), and Tukey's post hoc multiple comparison test (α=.05). The bond strength values of A and S were significantly higher than those of N ( P <.001 for both). However, statistically significant difference was not observed between group A and group S. According to the independent Student's t-test, the shear bond strength values of AT were significantly higher than those of AG ( P <.001). The surface treatment of polyamide denture base materials with acetic acid may be an efficient and cost-effective method for increasing the shear bond strength to auto-polymerized reline resin.
Liu, Ying-Pei; Liang, Hai-Ping; Gao, Zhong-Ke
2015-01-01
In order to improve the performance of voltage source converter-high voltage direct current (VSC-HVDC) system, we propose an improved auto-disturbance rejection control (ADRC) method based on least squares support vector machines (LSSVM) in the rectifier side. Firstly, we deduce the high frequency transient mathematical model of VSC-HVDC system. Then we investigate the ADRC and LSSVM principles. We ignore the tracking differentiator in the ADRC controller aiming to improve the system dynamic response speed. On this basis, we derive the mathematical model of ADRC controller optimized by LSSVM for direct current voltage loop. Finally we carry out simulations to verify the feasibility and effectiveness of our proposed control method. In addition, we employ the time-frequency representation methods, i.e., Wigner-Ville distribution (WVD) and adaptive optimal kernel (AOK) time-frequency representation, to demonstrate our proposed method performs better than the traditional method from the perspective of energy distribution in time and frequency plane.
Gao, Zhong-Ke
2015-01-01
In order to improve the performance of voltage source converter-high voltage direct current (VSC-HVDC) system, we propose an improved auto-disturbance rejection control (ADRC) method based on least squares support vector machines (LSSVM) in the rectifier side. Firstly, we deduce the high frequency transient mathematical model of VSC-HVDC system. Then we investigate the ADRC and LSSVM principles. We ignore the tracking differentiator in the ADRC controller aiming to improve the system dynamic response speed. On this basis, we derive the mathematical model of ADRC controller optimized by LSSVM for direct current voltage loop. Finally we carry out simulations to verify the feasibility and effectiveness of our proposed control method. In addition, we employ the time-frequency representation methods, i.e., Wigner-Ville distribution (WVD) and adaptive optimal kernel (AOK) time-frequency representation, to demonstrate our proposed method performs better than the traditional method from the perspective of energy distribution in time and frequency plane. PMID:26098556
Preliminary design package for Sunspot Domestic Hot Water Heating System
NASA Technical Reports Server (NTRS)
1976-01-01
The design review includes a drawing list, auto-control logic, measurement definitions, and other document pertaining to the solar heated prototype hot water systems and two heat exchangers. The hot water systems consist of the following subsystems: collector, storage, control transport, auxiliary energy, and site data acquisition.
Smart System for Bicarbonate Control in Irrigation for Hydroponic Precision Farming
Cambra, Carlos; Lacuesta, Raquel
2018-01-01
Improving the sustainability in agriculture is nowadays an important challenge. The automation of irrigation processes via low-cost sensors can to spread technological advances in a sector very influenced by economical costs. This article presents an auto-calibrated pH sensor able to detect and adjust the imbalances in the pH levels of the nutrient solution used in hydroponic agriculture. The sensor is composed by a pH probe and a set of micropumps that sequentially pour the different liquid solutions to maintain the sensor calibration and the water samples from the channels that contain the nutrient solution. To implement our architecture, we use an auto-calibrated pH sensor connected to a wireless node. Several nodes compose our wireless sensor networks (WSN) to control our greenhouse. The sensors periodically measure the pH level of each hydroponic support and send the information to a data base (DB) which stores and analyzes the data to warn farmers about the measures. The data can then be accessed through a user-friendly, web-based interface that can be accessed through the Internet by using desktop or mobile devices. This paper also shows the design and test bench for both the auto-calibrated pH sensor and the wireless network to check their correct operation. PMID:29693611
Smart System for Bicarbonate Control in Irrigation for Hydroponic Precision Farming.
Cambra, Carlos; Sendra, Sandra; Lloret, Jaime; Lacuesta, Raquel
2018-04-25
Improving the sustainability in agriculture is nowadays an important challenge. The automation of irrigation processes via low-cost sensors can to spread technological advances in a sector very influenced by economical costs. This article presents an auto-calibrated pH sensor able to detect and adjust the imbalances in the pH levels of the nutrient solution used in hydroponic agriculture. The sensor is composed by a pH probe and a set of micropumps that sequentially pour the different liquid solutions to maintain the sensor calibration and the water samples from the channels that contain the nutrient solution. To implement our architecture, we use an auto-calibrated pH sensor connected to a wireless node. Several nodes compose our wireless sensor networks (WSN) to control our greenhouse. The sensors periodically measure the pH level of each hydroponic support and send the information to a data base (DB) which stores and analyzes the data to warn farmers about the measures. The data can then be accessed through a user-friendly, web-based interface that can be accessed through the Internet by using desktop or mobile devices. This paper also shows the design and test bench for both the auto-calibrated pH sensor and the wireless network to check their correct operation.
Welch, B T; Coelho Prabhu, N; Walkoff, L; Trenkner, S W
2016-12-01
A 71-year-old male with 50-year history of Crohn's disease was evaluated for acute onset of dizziness and slurred speech. Blood ethanol levels were elevated despite abstinence from alcohol for over 30 years. CT enterography demonstrated massive dilation of the small bowel with anastomotic stricture. Auto-brewery syndrome may be considered in a patient with chronic obstruction or hypomotility presenting with elevated serum ethanol levels in the setting of high carbohydrate intake. Although treatment algorithms lack validation, judicious use of antibiotic therapy, carbohydrate control, and short courses of antifungal therapy have all been reported in the literature. Importantly, clinical consideration of 'auto-brewery' should be undertaken with substantial caution, given the lack of validated mechanisms linking endogenous ethanol production to peripheral blood ethanol. Copyright © 2016 European Crohn’s and Colitis Organisation (ECCO). Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.
NASA Technical Reports Server (NTRS)
Binkley, David M.; Verma, Nikhil; Crawford, Robert L.; Brandon, Erik; Jackson, Thomas N.
2004-01-01
Organic strain gauge and other sensors require high-gain, precision dc amplification to process their low-level output signals. Ideally, amplifiers would be fabricated using organic thin-film field-effect transistors (OTFT's) adjacent to the sensors. However, OTFT amplifiers exhibit low gain and high input-referred dc offsets that must be effectively managed. This paper presents a four-stage, cascaded differential OTFT amplifier utilizing switched capacitor auto-zeroing. Each stage provides a nominal voltage gain of four through a differential pair driving low-impedance active loads, which provide common-mode output voltage control. p-type pentacence OTFT's are used for the amplifier devices and auto-zero switches. Simulations indicate the amplifier provides a nominal voltage gain of 280 V/V and effectively amplifies a 1-mV dc signal in the presence of 500-mV amplifier input-referred dc offset voltages. Future work could include the addition of digital gain calibration and offset correction of residual offsets associated with charge injection imbalance in the differential circuits.
Adaptive threshold control for auto-rate fallback algorithm in IEEE 802.11 multi-rate WLANs
NASA Astrophysics Data System (ADS)
Wu, Qilin; Lu, Yang; Zhu, Xiaolin; Ge, Fangzhen
2012-03-01
The IEEE 802.11 standard supports multiple rates for data transmission in the physical layer. Nowadays, to improve network performance, a rate adaptation scheme called auto-rate fallback (ARF) is widely adopted in practice. However, ARF scheme suffers performance degradation in multiple contending nodes environments. In this article, we propose a novel rate adaptation scheme called ARF with adaptive threshold control. In multiple contending nodes environment, the proposed scheme can effectively mitigate the frame collision effect on rate adaptation decision by adaptively adjusting rate-up and rate-down threshold according to the current collision level. Simulation results show that the proposed scheme can achieve significantly higher throughput than the other existing rate adaptation schemes. Furthermore, the simulation results also demonstrate that the proposed scheme can effectively respond to the varying channel condition.
Deepak, Vemula; Challa, Ramasubba Reddy; Kamatham, Rekhalakshmi; Nuvvula, Sivakumar
2017-01-01
Background: Pain in the dental operatory can have a profound effect on the behavior of children. Aim: The aim of this study is to evaluate the pain perception while administering local infiltration, in children undergoing dental extractions, using a new auto-controlled injection system. Materials and Methods: Children in the age range of 6–10 years with teeth indicated for extraction were recruited and allocated to either Group I, computer-controlled injection system (auto system with special cartridge and compatible disposable 30-gauge, 10 mm needles), or Group II, traditional system (30-gauge, 10 mm needle and disposable traditional syringe). Local infiltration was administered and extraction performed after 3 min. The time of administration (TOA) of infiltrate was noted whereas anxiety and pain in both groups were assessed using the Modified Child Dental Anxiety Faces Scale simplified (MCDAS(f)), pulse rate, Faces Pain Scale-Revised (FPS-R), and Face, Legs, Activity, Cry, Consolability (FLACC) Scale. Results: The TOA was high in computer group, compared to the traditional system (P < 0.001***); however, anxiety and pain were significantly less in computer group as reported in MCDAS(f), pulse rate, FPS-R, and FLACC (P < 0.001***). Conclusions: Computer system created a positive and comfortable experience for the child, as well as the practitioner. The possibility of using buccal infiltration instead of inferior alveolar nerve block in children below 10 years was also demonstrated. PMID:28663636
Hammer, Martin; Königsdörffer, Ekkehart; Liebermann, Christiane; Framme, Carsten; Schuch, Günter; Schweitzer, Dietrich; Strobel, Jürgen
2008-01-01
Post-translational protein modification by lipid peroxidation products or glycation is a feature of aging as well as pathologic processes in postmitotic cells at the ocular fundus exposed to an oxidative environment. The accumulation of modified proteins such as those found in lipofuscin and advanced glycation end products (AGEs) contribute greatly to the fundus auto-fluorescence. The distinct fluorescence spectra of lipofuscin and AGE enable their differentiation in multispectral fundus fluorescence imaging. A dual-centre consecutive case series of 78 pseudo-phacic patients is reported. Digital colour fundus photographs as well as auto-fluorescence images were taken from 33 patients with age related macular degeneration (AMD), 13 patients with diabetic retinopathy (RD), or from 32 cases without pathologic findings (controls). Fluorescence was excited at 475-515 nm or 476-604 nm and recorded in the emission bands 530-675 nm or 675-715 nm, respectively. Fluorescence images excited at 475-515 nm were taken by a colour CCD-camera (colour-fluorescence imaging) enabling the separate recording of green and red fluorescence. The ratio of green versus red fluorescence was calculated within a representative region of each image. The 530-675 nm auto-fluorescence in AMD patients was dominated by the red emission (green vs. red ratio, g/r = 0.861). In comparison, the fluorescence of the diabetics was green-shifted (g/r = 0.946; controls: g/r = 0.869). Atrophic areas (geographic atrophy, laser scars) showed massive hypo-fluorescence in both emission bands. Hyper-fluorescent drusen and exudates, unobtrusive in the colour fundus images as well as in the fluorescence images with emission >667 nm, showed an impressive green-shift in the colour-fluorescence image. Lipofuscin is the dominant fluorophore at long wavelengths (>675 nm or red channel of the colour fluorescence image). In the green spectral region, we found an additional emission of collagen and elastin (optic disc, sclera) as well as deposits in drusen and exudates. The green shift of the auto-fluorescence in RD may be a hint of increased AGE concentrations.
Zhang, H.; Guo, H.; Lu, L.; Zahorchak, A. F.; Wiseman, R. W.; Raimondi, G.; Cooper, D. K. C.; Ezzelarab, M. B.; Thomson, A. W.
2016-01-01
Ex vivo-expanded cynomolgus monkey CD4+CD25+CD127− regulatory T cells (Treg) maintained Foxp3 demethylation status at the Treg-Specific Demethylation Region (TSDR), and potently suppressed T cell proliferation through 3 rounds of expansion. When CFSE- or VPD450-labeled autologous (auto) and non-autologous (non-auto) expanded Treg were infused into monkeys, the number of labeled auto-Treg in peripheral blood declined rapidly during the first week, but persisted at low levels in both normal and anti-thymocyte globulin plus rapamycin-treated (immunosuppressed; IS) animals for at least 3 weeks. By contrast, MHC-mismatched non-auto-Treg could not be detected in normal monkey blood or in blood of two out of the three IS monkeys by day 6 post-infusion. They were also more difficult to detect than auto-Treg in peripheral lymphoid tissue. Both auto- and non-auto-Treg maintained Ki67 expression early after infusion. Sequential monitoring revealed that adoptively-transferred auto-Treg maintained similarly high levels of Foxp3 and CD25 and low CD127 compared with endogenous Treg, although Foxp3 staining diminished over time in these non-transplanted recipients. Thus, infused ex vivo-expanded auto-Treg persist longer than MHC-mismatched non-auto-Treg in blood of non-human primates and can be detected in secondary lymphoid tissue. Host lymphodepletion and rapamycin administration did not consistently prolong the persistence of non-auto-Treg in these sites. PMID:25783759
Kumano, Osamu; Ieko, Masahiro; Komiyama, Yutaka; Naito, Sumiyoshi; Yoshida, Mika; Takahashi, Nobuhiko; Ohmura, Kazumasa; Hayasaki, Junki; Hayakawa, Mineji
2018-04-01
Laboratory determination of fibrin/fibrinogen degradation products (FDP) levels, along with that of the D-dimer, is important for assessing the fibrinolytic situation. Recently, we developed a new FDP reagent "Lias Auto P-FDP", which can detect various FDP fragments. The purpose of this study was to evaluate the basic performance of the newly developed Lias Auto P-FDP and compare it with Lias Auto D-Dimer Neo assay. The within-run precision of Lias Auto P-FDP and Lias Auto D-Dimer was determined 20 times in low and high value controls. The between-day precision was evaluated five times a day for five days. The linearity study was performed by diluting high value samples for 2 - 10-fold and 2 - 8-fold. The comparative study was performed using 172 patient samples with elevated FDP values. For the discrepancy analysis, the samples were divided into three groups by the discrepancy percentage between the FDP and D-dimer values. The groups were defined as follows: lower discrepancy group, less than -20%; no discrepancy group, -20% to 20%; upper discrepancy group, more than 20%. The coefficient of variation % (CV%) in within-run and between-day precision were within 3.8% for both FDP and the D-dimer. The correlation coefficients were more than 0.999 and the linearity was high. In the comparative study, the values of FDP were higher than that of the D-dimer in all samples. The median FDP and D-dimer values of lower discrepancy, no discrepancy, and upper discrepancy groups were 11.8, 20.3, and 51.4, and 8.0, 11.3, and 13.1, respectively. FDP showed an increasing tendency but D-Dimer showed constant values. Thus, the possible cause of discrepancy between FDP and D-dimer values were the elevated FDP values. In addition, the values of plasmin-α2 plasmin inhibitor complex (PIC) in the upper discrepancy group were higher than that of the lower and no discrepancy groups, indicating progression of fibrinolysis. In this study, we evaluated the newly developed Lias Auto P-FDP reagent and confirmed that the basic performance was acceptable. FDP was elevated in samples with high PIC values, which indicated progression of fibrinolysis. Determination of fibrinolysis conditions by FDP measurement is important.
NASA Astrophysics Data System (ADS)
Pradhan, Surya Narayan; Das, Aleena; Meena, Ramovatar; Nanda, Ranjan Kumar; Rajamani, Paulraj
2016-10-01
Occupational exposure to air pollution induces oxidative stress and prolonged exposure increases susceptibility to cardiovascular and respiratory diseases in several working groups. Biofluid of these subjects may reflect perturbed metabolic phenotypes. In this study we carried out a comparative molecular profiling study using parallel biofluids collected from subjects (n = 85) belonging to auto rickshaw drivers (ARD), traffic cops (TC) and office workers (OW). Higher levels of oxidative stress and inflammation markers in serum of ARD subjects were observed as compared to OW and TC. Uni and multivariate analyses of metabolites identified in urine by 1H NMR revealed 11 deregulated molecules in ARD subjects and involved in phenylalanine, histidine, arginine and proline metabolism. Despite contribution of confounding factors like exposure period, dietary factors including smoking and alcohol status, our results demonstrate existence of exposure specific metabotypes in biofluids of ARD, OW and TC groups. Monitoring serum oxidative stress and inflammation markers and urine metabolites by NMR may be useful to characterize perturbed metabolic phenotypes in populations exposed to urban traffic air pollution.
Economic evaluation of epinephrine auto-injectors for peanut allergy.
Shaker, Marcus; Bean, Katherine; Verdi, Marylee
2017-08-01
Three commercial epinephrine auto-injectors were available in the United States in the summer of 2016: EpiPen, Adrenaclick, and epinephrine injection, USP auto-injector. To describe the variation in pharmacy costs among epinephrine auto-injector devices in New England and evaluate the additional expense associated with incremental auto-injector costs. Decision analysis software was used to evaluate costs of the most and least expensive epinephrine auto-injector devices for children with peanut allergy. To evaluate regional variation in epinephrine auto-injector costs, a random sample of New England national and corporate pharmacies was compared with a convenience sample of pharmacies from 10 Canadian provinces. Assuming prescriptions written for 2 double epinephrine packs each year (home and school), the mean costs of food allergy over the 20-year model horizon totaled $58,667 (95% confidence interval [CI] $57,745-$59,588) when EpiPen was prescribed and $45,588 (95% CI $44,873-$46,304) when epinephrine injection, USP auto-injector was prescribed. No effectiveness differences were evident between groups, with 17.19 (95% CI 17.11-17.27) quality-adjusted life years accruing for each subject. The incremental cost per episode of anaphylaxis treated with epinephrine over the model horizon was $12,576 for EpiPen vs epinephrine injection, USP auto-injector. EpiPen costs were lowest at Canadian pharmacies ($96, 95% CI $85-$107). There was price consistency between corporate and independent pharmacies throughout New England by device brand, with the epinephrine injection, USP auto-injector being the most affordable device. Cost differences among epinephrine auto-injectors were significant. More expensive auto-injector brands did not appear to provide incremental benefit. Copyright © 2017 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Research on remote sensing image pixel attribute data acquisition method in AutoCAD
NASA Astrophysics Data System (ADS)
Liu, Xiaoyang; Sun, Guangtong; Liu, Jun; Liu, Hui
2013-07-01
The remote sensing image has been widely used in AutoCAD, but AutoCAD lack of the function of remote sensing image processing. In the paper, ObjectARX was used for the secondary development tool, combined with the Image Engine SDK to realize remote sensing image pixel attribute data acquisition in AutoCAD, which provides critical technical support for AutoCAD environment remote sensing image processing algorithms.
;border:0 }.ou-form textarea.form-control{height:auto }.ou-form .form-group{margin-bottom:15px }.ou-form -height:normal }.ou-form .btn,.ou-form .form-control{font-size:14px;line-height:1.42857143;background-image:none .form-control{display:block;width:100%;height:34px;padding:6px 12px;color:#555;background-color:#fff
Monogenic Auto-inflammatory Syndromes: A Review of the Literature.
Azizi, Gholamreza; Khadem Azarian, Shahin; Nazeri, Sepideh; Mosayebian, Ali; Ghiasy, Saleh; Sadri, Ghazal; Mohebi, Ali; Khan Nazer, Nikoo Hossein; Afraei, Sanaz; Mirshafiey, Abbas
2016-12-01
Auto-inflammatory syndromes are a new group of distinct hereditable disorders characterized by episodes of seemingly unprovoked inflammation (most commonly in skin, joints, gut, and eye), the absence of a high titer of auto-antibodies or auto-reactive T cells, and an inborn error of innate immunity. A narrative literature review was carried out of studies related to auto-inflammatory syndromes to discuss the pathogenesis and clinical manifestation of these syndromes. This review showed that the main monogenic auto-inflammatory syndromes are familial Mediterranean fever (FMF), mevalonate kinase deficiency (MKD), Blau syndrome, TNF receptor-associated periodic syndrome (TRAPS), cryopyrin-associated periodic syndrome (CAPS), and pyogenic arthritis with pyoderma gangrenosum and acne (PAPA). The data suggest that correct diagnosis and treatment of monogenic auto-inflammatory diseases relies on the physicians' awareness. Therefore, understanding of the underlying pathogenic mechanisms of auto-inflammatory syndromes, and especially the fact that these disorders are mediated by IL-1 secretion stimulated by monocytes and macrophages, facilitated significant progress in patient management.
14 CFR 61.67 - Category II pilot authorization requirements.
Code of Federal Regulations, 2014 CFR
2014-01-01
... attitude guidance displays; (iv) Use and limitations of RVR; (v) Use of visual clues, their availability or... be made with the use of an approved flight control guidance system, except if an approved auto...
14 CFR 61.67 - Category II pilot authorization requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... attitude guidance displays; (iv) Use and limitations of RVR; (v) Use of visual clues, their availability or... be made with the use of an approved flight control guidance system, except if an approved auto...
14 CFR 61.67 - Category II pilot authorization requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... attitude guidance displays; (iv) Use and limitations of RVR; (v) Use of visual clues, their availability or... be made with the use of an approved flight control guidance system, except if an approved auto...
46 CFR 167.65-35 - Use of auto pilot.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the automatic pilot is used in— (a) Areas of high traffic density; (b) Conditions of restricted... possible to immediately establish human control of the ship's steering: (2) A competent person is ready at...
46 CFR 167.65-35 - Use of auto pilot.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the automatic pilot is used in— (a) Areas of high traffic density; (b) Conditions of restricted... possible to immediately establish human control of the ship's steering: (2) A competent person is ready at...
46 CFR 167.65-35 - Use of auto pilot.
Code of Federal Regulations, 2012 CFR
2012-10-01
... the automatic pilot is used in— (a) Areas of high traffic density; (b) Conditions of restricted... possible to immediately establish human control of the ship's steering: (2) A competent person is ready at...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-06
... observation, wildlife photography, auto touring, birding, hiking, boating/canoeing, visitor center, special...: Visitors to national wildlife refuges. Respondent's Obligation: Required to obtain or retain a benefit...
47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...
47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...
47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...
47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...
47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...
GPS Auto-Navigation Design for Unmanned Air Vehicles
NASA Technical Reports Server (NTRS)
Nilsson, Caroline C. A.; Heinzen, Stearns N.; Hall, Charles E., Jr.; Chokani, Ndaona
2003-01-01
A GPS auto-navigation system is designed for Unmanned Air Vehicles. The objective is to enable the air vehicle to be used as a test-bed for novel flow control concepts. The navigation system uses pre-programmed GPS waypoints. The actual GPS position, heading, and velocity are collected by the flight computer, a PC104 system running in Real-Time Linux, and compared with the desired waypoint. The navigator then determines the necessity of a heading correction and outputs the correction in the form of a commanded bank angle, for a level coordinated turn, to the controller system. This controller system consists of 5 controller! (pitch rate PID, yaw damper, bank angle PID, velocity hold, and altitude hold) designed for a closed loop non-linear aircraft model with linear aerodynamic coefficients. The ability and accuracy of using GPS data, is validated by a GPS flight. The autopilots are also validated in flight. The autopilot unit flight validations show that the designed autopilots function as designed. The aircraft model, generated on Matlab SIMULINK is also enhanced by the flight data to accurately represent the actual aircraft.
Female Infertility and Serum Auto-antibodies: a Systematic Review.
Deroux, Alban; Dumestre-Perard, Chantal; Dunand-Faure, Camille; Bouillet, Laurence; Hoffmann, Pascale
2017-08-01
On average, 10 % of infertile couples have unexplained infertility. Auto-immune disease (systemic lupus erythematosus, anti-phospholipid syndrome) accounts for a part of these cases. In the last 20 years, aspecific auto-immunity, defined as positivity of auto-antibodies in blood sample without clinical or biological criteria for defined diseases, has been evoked in a subpopulation of infertile women. A systematic review was performed (PUBMED) using the MESH search terms "infertility" and "auto-immunity" or "reproductive technique" or "assisted reproduction" or "in vitro fertilization" and "auto-immunity." We retained clinical and physiopathological studies that were applicable to the clinician in assuming joint management of both infertility associated with serum auto-antibodies in women. Thyroid auto-immunity which affects thyroid function could be a cause of infertility; even in euthyroidia, the presence of anti-thyroperoxydase antibodies and/or thyroglobulin are related to infertility. The presence of anti-phospholipid (APL) and/or anti-nuclear (ANA) antibodies seems to be more frequent in the population of infertile women; serum auto-antibodies are associated with early ovarian failure, itself responsible for fertility disorders. However, there exist few publications on this topic. The methods of dosage, as well as the clinical criteria of unexplained infertility deserve to be standardized to allow a precise response to the question of the role of serum auto-antibodies in these women. The direct pathogenesis of this auto-immunity is unknown, but therapeutic immunomodulators, prescribed on a case-by-case basis, could favor pregnancy even in cases of unexplained primary or secondary infertility.
Administration of the adrenaline auto-injector at the nursery/kindergarten/school in Western Japan.
Korematsu, Seigo; Fujitaka, Michiko; Ogata, Mika; Zaitsu, Masafumi; Motomura, Chikako; Kuzume, Kazuyo; Toku, Yuchiro; Ikeda, Masanori; Odajima, Hiroshi
2017-01-01
In view of the increasing prevalence of food allergies, there has been an associated increase in frequency of situations requiring an emergency response for anaphylaxis at the home, childcare facilities and educational institutions. To clarify the situation of adrenaline auto-injector administration in nursery/kindergarten/school, we carried out a questionnaire survey on pediatric physicians in Western Japan. In 2015, self-reported questionnaires were mailed to 421 physicians who are members of the West Japan Research Society Pediatric Clinical Allergy and Shikoku Research Society Pediatric Clinical Allergy. The response rate was 44% (185 physicians) where 160 physicians had a prescription registration for the adrenaline auto-injector. In the past year, 1,330 patients were prescribed the adrenaline auto-injector where 83 patients (6% of the prescribed patients) actually administered the adrenaline auto-injector, of which 14 patients (17% of the administered patients) self-administered the adrenaline auto-injector. "Guardians" at the nursery/kindergarten and elementary school were found to have administered the adrenaline auto-injector the most. Among 117 adrenaline auto-injector prescription-registered physicians, 79% had experienced nonadministration of adrenaline auto-injector at nursery/kindergarten/school when anaphylaxis has occurred. The most frequent reason cited for not administering the adrenaline auto-injector was "hesitation about the timing of administration." If the adrenaline auto-injector was administered after the guardian arrived at the nursery/kindergarten/school, it may lead to delayed treatment of anaphylaxis in which symptoms develop in minutes. Education and cooperation among physicians and nursery/kindergarten/school staff will reduce the number of children suffering unfortunate outcomes due to anaphylaxis.
First experience with THE AUTOLAP™ SYSTEM: an image-based robotic camera steering device.
Wijsman, Paul J M; Broeders, Ivo A M J; Brenkman, Hylke J; Szold, Amir; Forgione, Antonello; Schreuder, Henk W R; Consten, Esther C J; Draaisma, Werner A; Verheijen, Paul M; Ruurda, Jelle P; Kaufman, Yuval
2018-05-01
Robotic camera holders for endoscopic surgery have been available for 20 years but market penetration is low. The current camera holders are controlled by voice, joystick, eyeball tracking, or head movements, and this type of steering has proven to be successful but excessive disturbance of surgical workflow has blocked widespread introduction. The Autolap™ system (MST, Israel) uses a radically different steering concept based on image analysis. This may improve acceptance by smooth, interactive, and fast steering. These two studies were conducted to prove safe and efficient performance of the core technology. A total of 66 various laparoscopic procedures were performed with the AutoLap™ by nine experienced surgeons, in two multi-center studies; 41 cholecystectomies, 13 fundoplications including hiatal hernia repair, 4 endometriosis surgeries, 2 inguinal hernia repairs, and 6 (bilateral) salpingo-oophorectomies. The use of the AutoLap™ system was evaluated in terms of safety, image stability, setup and procedural time, accuracy of imaged-based movements, and user satisfaction. Surgical procedures were completed with the AutoLap™ system in 64 cases (97%). The mean overall setup time of the AutoLap™ system was 4 min (04:08 ± 0.10). Procedure times were not prolonged due to the use of the system when compared to literature average. The reported user satisfaction was 3.85 and 3.96 on a scale of 1 to 5 in two studies. More than 90% of the image-based movements were accurate. No system-related adverse events were recorded while using the system. Safe and efficient use of the core technology of the AutoLap™ system was demonstrated with high image stability and good surgeon satisfaction. The results support further clinical studies that will focus on usability, improved ergonomics and additional image-based features.
Shi, Hai-Bo; Cheng, Lei; Nakayama, Meiho; Kakazu, Yasuhiro; Yin, Min; Miyoshi, Akira; Komune, Shizuo
2005-09-01
Automatic continuous positive airway pressure (auto-CPAP) machines differ mainly in algorithms used for respiratory event detection and pressure control. The auto-CPAP machines operated by novel algorithms are expected to have better performance than the earlier ones in the treatment of obstructive sleep apnea syndrome (OSAS). The purpose of this study was to determine the therapeutic characteristics between two different auto-CPAP devices, i.e., the third-generation flow-based (f-APAP) and the second-generation vibration-based (v-APAP) machines, during the first night treatment of OSAS. We retrospectively reviewed the polysomnography (PSG) recordings of 43 OSAS patients who were initially performed an overnight diagnostic PSG to confirm the disease and afterwards received the first night auto-CPAP treatment with using either the f-APAP (n=22) or v-APAP (n=21) device under another PSG evaluation. There were 13.6% and 61.9% patients who remained a residual apnea/hypopnea index more than 5 during the f-APAP and v-APAP application, respectively (P<0.005). The f-APAP was more effective than the v-APAP in reducing apnea/hypopnea index (P=0.003), hypopnea index (P=0.023) and apnea index (P=0.007), improving the lowest oxygen saturation index (P=0.007) and shortening stage 1 sleep (P=0.016). However, the f-APAP was less sufficient than the v-APAP in reducing arousal/awakening index (P=0.02). These findings suggest that the f-APAP works better than the v-APAP in abolishing breathing abnormities in the treatment of OSAS; however, the f-APAP device might still have some potential limitations in the clinical application.
V-TECS Guide for Auto Body Repair.
ERIC Educational Resources Information Center
Gregory, Margaret R.; Benson, Robert T.
This curriculum guide consists of materials for teaching a course in auto body repair. Addressed in the individual units of the guide are the following topics: the nature and scope of auto body repair; safety; tools; auto body construction; simple metal straightening; welding; painting and refinishing; refinishing complete lacquer; refinishing…
Conversations with AutoTutor Help Students Learn
ERIC Educational Resources Information Center
Graesser, Arthur C.
2016-01-01
AutoTutor helps students learn by holding a conversation in natural language. AutoTutor is adaptive to the learners' actions, verbal contributions, and in some systems their emotions. Many of AutoTutor's conversation patterns simulate human tutoring, but other patterns implement ideal pedagogies that open the door to computer tutors eclipsing…
NASA Astrophysics Data System (ADS)
Gaddam, Vamsidhar Reddy; Griwodz, Carsten; Halvorsen, Pâl.
2014-02-01
One of the most common ways of capturing wide eld-of-view scenes is by recording panoramic videos. Using an array of cameras with limited overlapping in the corresponding images, one can generate good panorama images. Using the panorama, several immersive display options can be explored. There is a two fold synchronization problem associated to such a system. One is the temporal synchronization, but this challenge can easily be handled by using a common triggering solution to control the shutters of the cameras. The other synchronization challenge is the automatic exposure synchronization which does not have a straight forward solution, especially in a wide area scenario where the light conditions are uncontrolled like in the case of an open, outdoor football stadium. In this paper, we present the challenges and approaches for creating a completely automatic real-time panoramic capture system with a particular focus on the camera settings. One of the main challenges in building such a system is that there is not one common area of the pitch that is visible to all the cameras that can be used for metering the light in order to nd appropriate camera parameters. One approach we tested is to use the green color of the eld grass. Such an approach provided us with acceptable results only in limited light conditions.A second approach was devised where the overlapping areas between adjacent cameras are exploited, thus creating pairs of perfectly matched video streams. However, there still existed some disparity between di erent pairs. We nally developed an approach where the time between two temporal frames is exploited to communicate the exposures among the cameras where we achieve a perfectly synchronized array. An analysis of the system and some experimental results are presented in this paper. In summary, a pilot-camera approach running in auto-exposure mode and then distributing the used exposure values to the other cameras seems to give best visual results.
NASA Astrophysics Data System (ADS)
Chancy, Carl H.
A device for performing an objective eye exam has been developed to automatically determine ophthalmic prescriptions. The closed loop fluidic auto-phoropter has been designed, modeled, fabricated and tested for the automatic measurement and correction of a patient's prescriptions. The adaptive phoropter is designed through the combination of a spherical-powered fluidic lens and two cylindrical fluidic lenses that are orientated 45o relative to each other. In addition, the system incorporates Shack-Hartmann wavefront sensing technology to identify the eye's wavefront error and corresponding prescription. Using the wavefront error information, the fluidic auto-phoropter nulls the eye's lower order wavefront error by applying the appropriate volumes to the fluidic lenses. The combination of the Shack-Hartmann wavefront sensor the fluidic auto-phoropter allows for the identification and control of spherical refractive error, as well as cylinder error and axis; thus, creating a truly automated refractometer and corrective system. The fluidic auto-phoropter is capable of correcting defocus error ranging from -20D to 20D and astigmatism from -10D to 10D. The transmissive see-through design allows for the observation of natural scenes through the system at varying object planes with no additional imaging optics in the patient's line of sight. In this research, two generations of the fluidic auto-phoropter are designed and tested; the first generation uses traditional glass optics for the measurement channel. The second generation of the fluidic auto-phoropter takes advantage of the progress in the development of holographic optical elements (HOEs) to replace all the traditional glass optics. The addition of the HOEs has enabled the development of a more compact, inexpensive and easily reproducible system without compromising its performance. Additionally, the fluidic lenses were tested during a National Aeronautics Space Administration (NASA) parabolic flight campaign, to determine the effect of varying gravitational acceleration on the performance and image quality of the fluidic lenses. Wavefront analysis has indicated that flight turbulence and the varying levels of gravitational acceleration ranging from zero-G (microgravity) to 2G (hypergravity) had minimal effect on the performance of the fluidic lenses, except for small changes in defocus; making them suitable for potential use in a portable space-based fluidic auto-phoropter.
Kaufmann, Tobias; Völker, Stefan; Gunesch, Laura; Kübler, Andrea
2012-01-01
Brain-computer interfaces (BCI) based on event-related potentials (ERP) allow for selection of characters from a visually presented character-matrix and thus provide a communication channel for users with neurodegenerative disease. Although they have been topic of research for more than 20 years and were multiply proven to be a reliable communication method, BCIs are almost exclusively used in experimental settings, handled by qualified experts. This study investigates if ERP-BCIs can be handled independently by laymen without expert support, which is inevitable for establishing BCIs in end-user's daily life situations. Furthermore we compared the classic character-by-character text entry against a predictive text entry (PTE) that directly incorporates predictive text into the character-matrix. N = 19 BCI novices handled a user-centered ERP-BCI application on their own without expert support. The software individually adjusted classifier weights and control parameters in the background, invisible to the user (auto-calibration). All participants were able to operate the software on their own and to twice correctly spell a sentence with the auto-calibrated classifier (once with PTE, once without). Our PTE increased spelling speed and, importantly, did not reduce accuracy. In sum, this study demonstrates feasibility of auto-calibrating ERP-BCI use, independently by laymen and the strong benefit of integrating predictive text directly into the character-matrix.
Schistosome Infection Intensity Is Inversely Related to Auto-Reactive Antibody Levels
Mutapi, Francisca; Imai, Natsuko; Nausch, Norman; Bourke, Claire D.; Rujeni, Nadine; Mitchell, Kate M.; Midzi, Nicholas; Woolhouse, Mark E. J.; Maizels, Rick M.; Mduluza, Takafira
2011-01-01
In animal experimental models, parasitic helminth infections can protect the host from auto-immune diseases. We conducted a population-scale human study investigating the relationship between helminth parasitism and auto-reactive antibodies and the subsequent effect of anti-helminthic treatment on this relationship. Levels of antinuclear antibodies (ANA) and plasma IL-10 were measured by enzyme linked immunosorbent assay in 613 Zimbabweans (aged 2–86 years) naturally exposed to the blood fluke Schistosoma haematobium. ANA levels were related to schistosome infection intensity and systemic IL-10 levels. All participants were offered treatment with the anti-helminthic drug praziquantel and 102 treated schoolchildren (5–16 years) were followed up 6 months post-antihelminthic treatment. ANA levels were inversely associated with current infection intensity but were independent of host age, sex and HIV status. Furthermore, after allowing for the confounding effects of schistosome infection intensity, ANA levels were inversely associated with systemic levels of IL-10. ANA levels increased significantly 6 months after anti-helminthic treatment. Our study shows that ANA levels are attenuated in helminth-infected humans and that anti-helminthic treatment of helminth-infected people can significantly increase ANA levels. The implications of these findings are relevant for understanding both the aetiology of immune disorders mediated by auto-reactive antibodies and in predicting the long-term consequences of large-scale schistosomiasis control programs. PMID:21573157
Kaufmann, Tobias; Völker, Stefan; Gunesch, Laura; Kübler, Andrea
2012-01-01
Brain–computer interfaces (BCI) based on event-related potentials (ERP) allow for selection of characters from a visually presented character-matrix and thus provide a communication channel for users with neurodegenerative disease. Although they have been topic of research for more than 20 years and were multiply proven to be a reliable communication method, BCIs are almost exclusively used in experimental settings, handled by qualified experts. This study investigates if ERP–BCIs can be handled independently by laymen without expert support, which is inevitable for establishing BCIs in end-user’s daily life situations. Furthermore we compared the classic character-by-character text entry against a predictive text entry (PTE) that directly incorporates predictive text into the character-matrix. N = 19 BCI novices handled a user-centered ERP–BCI application on their own without expert support. The software individually adjusted classifier weights and control parameters in the background, invisible to the user (auto-calibration). All participants were able to operate the software on their own and to twice correctly spell a sentence with the auto-calibrated classifier (once with PTE, once without). Our PTE increased spelling speed and, importantly, did not reduce accuracy. In sum, this study demonstrates feasibility of auto-calibrating ERP–BCI use, independently by laymen and the strong benefit of integrating predictive text directly into the character-matrix. PMID:22833713
Schwebel, David C; Johnston, Anna; Shen, Jiabin; Li, Peng
2017-07-19
Transportation-related injuries are a leading cause of pediatric death, and effective interventions are limited. Otto the Auto is a website offering engaging, interactive activities. We evaluated Otto among a sample of sixty-nine 4- and 5-year-old children, who participated in a randomized parallel group design study. Following baseline evaluation, children engaged with either Otto or a control website for 2 weeks and then were re-evaluated. Children who used Otto failed to show increases in transportation safety knowledge or behavior compared to the control group, although there was a dosage effect whereby children who engaged in the website more with parents gained safer behavior patterns. We conclude Otto may have some efficacy when engaged by children with their parents, but continued efforts to develop and refine engaging, effective, theory-driven strategies to teach children transportation safety, including via internet, should be pursued.
Synergistic Effect of Auto-Activation and Small RNA Regulation on Gene Expression
NASA Astrophysics Data System (ADS)
Xiong, Li-Ping; Ma, Yu-Qiang; Tang, Lei-Han
2010-09-01
Auto-activation and small ribonucleic acid (RNA)-mediated regulation are two important mechanisms in controlling gene expression. We study the synergistic effect of these two regulations on gene expression. It is found that under this combinatorial regulation, gene expression exhibits bistable behaviors at the transition regime, while each of these two regulations, if working solely, only leads to monostability. Within the stochastic framework, the base pairing strength between sRNA and mRNA plays an important role in controlling the transition time between on and off states. The noise strength of protein number in the off state approaches 1 and is smaller than that in the on state. The noise strength also depends on which parameters, the feedback strength or the synthesis rate of small RNA, are tuned in switching the gene expression on and off. Our findings may provide a new insight into gene-regulation mechanism and can be applied in synthetic biology.
Johnston, Anna; Shen, Jiabin; Li, Peng
2017-01-01
Transportation-related injuries are a leading cause of pediatric death, and effective interventions are limited. Otto the Auto is a website offering engaging, interactive activities. We evaluated Otto among a sample of sixty-nine 4- and 5-year-old children, who participated in a randomized parallel group design study. Following baseline evaluation, children engaged with either Otto or a control website for 2 weeks and then were re-evaluated. Children who used Otto failed to show increases in transportation safety knowledge or behavior compared to the control group, although there was a dosage effect whereby children who engaged in the website more with parents gained safer behavior patterns. We conclude Otto may have some efficacy when engaged by children with their parents, but continued efforts to develop and refine engaging, effective, theory-driven strategies to teach children transportation safety, including via internet, should be pursued. PMID:28753920
Auto-tuning system for NMR probe with LabView
NASA Astrophysics Data System (ADS)
Quen, Carmen; Mateo, Olivia; Bernal, Oscar
2013-03-01
Typical manual NMR-tuning method is not suitable for broadband spectra spanning several megahertz linewidths. Among the main problems encountered during manual tuning are pulse-power reproducibility, baselines, and transmission line reflections, to name a few. We present a design of an auto-tuning system using graphic programming language, LabVIEW, to minimize these problems. The program is designed to analyze the detected power signal of an antenna near the NMR probe and use this analysis to automatically tune the sample coil to match the impedance of the spectrometer (50 Ω). The tuning capacitors of the probe are controlled by a stepper motor through a LabVIEW/computer interface. Our program calculates the area of the power signal as an indicator to control the motor so disconnecting the coil to tune it through a network analyzer is unnecessary. Work supported by NSF-DMR 1105380
NASA Astrophysics Data System (ADS)
Zhao, H.; Zhang, S.
2008-01-01
One of the most effective means to achieve controlled auto-ignition (CAI) combustion in a gasoline engine is by the residual gas trapping method. The amount of residual gas and mixture composition have significant effects on the subsequent combustion process and engine emissions. In order to obtain quantitative measurements of in-cylinder residual gas concentration and air/fuel ratio, a spontaneous Raman scattering (SRS) system has been developed recently. The optimized optical SRS setups are presented and discussed. The temperature effect on the SRS measurement is considered and a method has been developed to correct for the overestimated values due to the temperature effect. Simultaneous measurements of O2, H2O, CO2 and fuel were obtained throughout the intake, compression, combustion and expansion strokes. It shows that the SRS can provide valuable data on this process in a CAI combustion engine.
Automatic Scaling of Digisonde Ionograms Test and Evaluation Report.
1982-09-01
Labrador 30 21 IManual MUF - Auto MUFj/Manual MUF April 1980 Goose Bay, Labrador 31 22 IManual MUF - Auto MUFI /Manual MUF July 1980 Goose Bay...Labrador 32 23 IManual MUF - Auto MUFI /Manual MUF September 1980 Goose Bay, Labrador 33 24 !Manual M(3000) - Auto M(3000)1 January 1980 Goose Bay, Labrador
;height:auto;overflow:hidden}.poc_table .top_row{background-color:#eee;height:auto;overflow:hidden}.poc_table ;background-color:#FFF;height:auto;overflow:hidden;border-top:1px solid #ccc}.poc_table .main_row .name :200px;padding:5px;height:auto;overflow:hidden}.tli_grey_box{background-color:#eaeaea;text-align:center
Clinical utility of anti-p53 auto-antibody: systematic review and focus on colorectal cancer.
Suppiah, Aravind; Greenman, John
2013-08-07
Mutation of the p53 gene is a key event in the carcinogenesis of many different types of tumours. These can occur throughout the length of the p53 gene. Anti-p53 auto-antibodies are commonly produced in response to these p53 mutations. This review firstly describes the various mechanisms of p53 dysfunction and their association with subsequent carcinogenesis. Following this, the mechanisms of induction of anti-p53 auto-antibody production are shown, with various hypotheses for the discrepancies between the presence of p53 mutation and the presence/absence of anti-p53 auto-antibodies. A systematic review was performed with a descriptive summary of key findings of each anti-p53 auto-antibody study in all cancers published in the last 30 years. Using this, the cumulative frequency of anti-p53 auto-antibody in each cancer type is calculated and then compared with the incidence of p53 mutation in each cancer to provide the largest sample calculation and correlation between mutation and anti-p53 auto-antibody published to date. Finally, the review focuses on the data of anti-p53 auto-antibody in colorectal cancer studies, and discusses future strategies including the potentially promising role using anti-p53 auto-antibody presence in screening and surveillance.
Parmar, S; Kongtim, P; Champlin, R; Dinh, Y; Elgharably, Y; Wang, M; Bashir, Q; Shah, J J; Shah, N; Popat, U; Giralt, S A; Orlowski, R Z; Qazilbash, M H
2014-08-01
Optimal treatment approach continues to remain a challenge for systemic light chain amyloidosis (AL). So far, Auto-SCT is the only modality associated with long-term survival. However, failure to show survival benefit in randomized study raises questions regarding its efficacy. We present a comparative outcome analysis of Auto-SCT to conventional therapies (CTR) in AL patients treated over a 14-year period at our institution. Out of the 145 AL amyloidosis patients, Auto-SCT was performed in 80 patients with 1-year non-relapse mortality rate of 12.5%. Novel agents were used as part of induction therapy in 56% of transplant recipients vs 46% of CTR patients. Hematological and organ responses were seen in 74.6% and 39% in the Auto-SCT arm vs 53% and 12% in the CTR arm, respectively. The projected 5-year survival for Auto-SCT vs CTR was 63% vs 38%, respectively. Landmark analysis of patients alive at 1-year after diagnosis showed improved 5-year OS of 72% with Auto-SCT vs 65% in the CTR arm. In the multivariate analysis, age <60 years, induction therapy with novel agents, kidney only involvement and Auto-SCT were associated with improved survival. In conclusion, Auto-SCT is associated with long-term survival for patients with AL amyloidosis.
Fline-Barthes, M-H; Vandendriessche, D; Gaugue, J; Urso, L; Therby, D; Subtil, D
2015-05-01
To evaluate auto-questionnaire use for psychosocial vulnerability and substance use (smoking, alcohol consumption, depression, intimate violence) screening during pregnancy versus usual medical report. An auto-questionnaire based on validated tests (Fagerström/HSI, T-ACE, EPDS, SSQ6) was proposed to 1977 pregnant patients at their first obstetrical consultation. We compared results of auto-questionnaire and usual medical questioning. The auto-questionnaire was filled by 1676 pregnant patients (89.4 %). The two Fagerström/HIS questions showed that 20.7 % smoked during pregnancy. T-ACE score was better than usual medical questioning to detect excessive alcohol consumption (4.0 % vs 0.1 %, P<0.05). Drug use before pregnancy was reported by 9.8 % patients in auto-questionnaire, but was only found in 4.9 % of medical files (P<0.001). Seven percent patients reported at least 3 depressive symptoms on 4 purposed in auto-questionnaire. Intimate violence, physical or psychological, was reported in 9.4 %. All of these vulnerability factors were linked together, in auto-questionnaire or in usual medical reports. Using auto-questionnaire based on standardized screening tests could help medical practioneers to detect psychosocial vulnerability and/or substance use during pregnancy. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Glavey, S V; Gertz, M A; Dispenzieri, A; Kumar, S; Buadi, F; Lacy, M; Hayman, S R; Kapoor, P; Dingli, D; McCurdy, A; Hogan, W J; Gastineau, D A; Leung, N
2013-11-01
Renal failure commonly complicates multiple myeloma (MM) and is associated with reduced survival. It is not clear whether auto-SCT results in improved renal function or attainment of independence from dialysis in patients with advanced renal impairment due to MM. We conducted a retrospective cohort study of all patients who underwent auto-SCT for MM complicated by advanced renal failure at our institution over a 10-year period (2000-2010). We aimed to assess the association between auto-SCT and renal outcome in patients with serum creatinine (SCr) over 3 mg/dL, attributable to MM, including those who were dialysis dependent. Thirty patients (2.8% of all auto-SCT patients) met inclusion criteria. Fourteen of 15 patients who were dialysis dependent before auto-SCT remained dialysis dependent in the long term despite hematological response (HR). Of the remaining 15 patients with SCr >3 mg/dL, an improvement in glomerular filtration rate (GFR) from 15 to 19.4 mL/min/1.73 m(2) was noted post auto-SCT (P=0.035); however, neither HR post auto-SCT or pre-existing renal function were independently associated with renal outcome. Auto-SCT was not associated with independence from dialysis in patients with renal failure due to MM at our institution. Although auto-SCT was associated with an improvement in GFR in patients with SCr >3 mg/dL, this improvement was not related to HR.
Kang, Ji-Man; Lee, Ji Won; Yoo, Keon Hee; Kim, Yae-Jean; Sung, Ki Woong; Koo, Hong Hoe
2016-01-01
We retrospectively analyzed infectious complications during tandem high-dose chemotherapy and autologous stem cell transplantation (HDCT/auto-SCT) in children and adolescents with high-risk or recurrent solid tumors. A total of 324 patients underwent their first HDCT/auto-SCT between October 2004 and September 2014, and 283 of them proceeded to their second HDCT/auto-SCT (a total of 607 HDCT/auto-SCTs). During the early transplant period of 607 HDCT/auto-SCTs (from the beginning of HDCT to day 30 post-transplant), bacteremia, urinary tract infection (UTI), respiratory virus infection, and varicella zoster virus (VZV) reactivation occurred in 7.1%, 2.3%, 13.0%, and 2.5% of HDCT/auto-SCTs, respectively. The early transplant period of the second HDCT/auto-SCT had infectious complications similar to the first HDCT/auto-SCT. During the late transplant period of HDCT/auto-SCT (from day 31 to 1 year post-transplant), bacteremia, UTI, and VZV reactivation occurred in 7.5%, 2.5%, and 3.9% of patients, respectively. Most infectious complications in the late transplant period occurred during the first 6 months post-transplant. There were no invasive fungal infections during the study period. Six patients died from infectious complications (4 from bacterial sepsis and 2 from respiratory virus infection). Our study suggests that infectious complications are similar following second and first HDCT/auto-SCT in children. PMID:27627440
On-road PM2.5 pollution exposure in multiple transport microenvironments in Delhi
NASA Astrophysics Data System (ADS)
Goel, Rahul; Gani, Shahzad; Guttikunda, Sarath K.; Wilson, Daniel; Tiwari, Geetam
2015-12-01
PM2.5 pollution in Delhi averaged 150 μg/m3 from 2012 through 2014, which is 15 times higher than the World Health Organization's annual-average guideline. For this setting, we present on-road exposure of PM2.5 concentrations for 11 transport microenvironments along a fixed 8.3-km arterial route, during morning rush hour. The data collection was carried out using a portable TSI DustTrak DRX 8433 aerosol monitor, between January and May (2014). The monthly-average measured ambient concentrations varied from 130 μg/m3 to 250 μg/m3. The on-road PM2.5 concentrations exceeded the ambient measurements by an average of 40% for walking, 10% for cycle, 30% for motorised two wheeler (2W), 30% for open-windowed (OW) car, 30% for auto rickshaw, 20% for air-conditioned as well as for OW bus, 20% for bus stop, and 30% for underground metro station. On the other hand, concentrations were lower by 50% inside air-conditioned (AC) car and 20% inside the metro rail carriage. We find that the percent exceedance for open modes (cycle, auto rickshaw, 2W, OW car, and OW bus) reduces non-linearly with increasing ambient concentration. The reduction is steeper at concentrations lower than 150 μg/m3 than at higher concentrations. After accounting for air inhalation rate and speed of travel, PM2.5 mass uptake per kilometer during cycling is 9 times of AC car, the mode with the lowest exposure. At current level of concentrations, an hour of cycling in Delhi during morning rush-hour period results in PM2.5 dose which is 40% higher than an entire-day dose in cities like Tokyo, London, and New York, where ambient concentrations range from 10 to 20 μg/m3.
1978-09-01
Strategy for a Class of Static Systems", IEEE Trans, on Auto. Cont., AC-17, 7-15 (1972). 14. Findeisen , W., and Lefkowitz, I., "Design and Applications...of Multilayer Control", Proc. Fourth IFAC Congress, Warsaw, 1969. 15. Findeisen , W., Multilevel Control Systems, Panstwowe Wydawnictwo Naukowe
Casulo, Carla; Friedberg, Jonathan W; Ahn, Kwang W; Flowers, Christopher; DiGilio, Alyssa; Smith, Sonali M; Ahmed, Sairah; Inwards, David; Aljurf, Mahmoud; Chen, Andy I; Choe, Hannah; Cohen, Jonathon; Copelan, Edward; Farooq, Umar; Fenske, Timothy S; Freytes, Cesar; Gaballa, Sameh; Ganguly, Siddhartha; Jethava, Yogesh; Kamble, Rammurti T; Kenkre, Vaishalee P; Lazarus, Hillard; Lazaryan, Aleksandr; Olsson, Richard F; Rezvani, Andrew R; Rizzieri, David; Seo, Sachiko; Shah, Gunjan L; Shah, Nina; Solh, Melham; Sureda, Anna; William, Basem; Cumpston, Aaron; Zelenetz, Andrew D; Link, Brian K; Hamadani, Mehdi
2018-06-01
Patients with follicular lymphoma (FL) experiencing early therapy failure (ETF) within 2 years of frontline chemoimmunotherapy have poor overall survival (OS). We analyzed data from the Center for International Blood and Marrow Transplant Research (CIBMTR) and the National LymphoCare Study (NLCS) to determine whether autologous hematopoietic cell transplant (autoHCT) can improve outcomes in this high-risk FL subgroup. ETF was defined as failure to achieve at least partial response after frontline chemoimmunotherapy or lymphoma progression within 2 years of frontline chemoimmunotherapy. We identified 2 groups: the non-autoHCT cohort (patients from the NLCS with ETF not undergoing autoHCT) and the autoHCT cohort (CIBMTR patients with ETF undergoing autoHCT). All patients received rituximab-based chemotherapy as frontline treatment; 174 non-autoHCT patients and 175 autoHCT patients were identified and analyzed. There was no difference in 5-year OS between the 2 groups (60% versus 67%, respectively; P = .16). A planned subgroup analysis showed that patients with ETF receiving autoHCT soon after treatment failure (≤1 year of ETF; n = 123) had higher 5-year OS than those without autoHCT (73% versus 60%, P = .05). On multivariate analysis, early use of autoHCT was associated with significantly reduced mortality (hazard ratio, .63; 95% confidence interval, .42 to .94; P = .02). Patients with FL experiencing ETF after frontline chemoimmunotherapy lack optimal therapy. We demonstrate improved OS when receiving autoHCT within 1 year of treatment failure. Results from this unique collaboration between the NLCS and CIBMTR support consideration of early consolidation with autoHCT in select FL patients experiencing ETF. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
Yu, J S; Chen, W J; Ni, M H; Chan, W H; Yang, S D
1998-08-15
Autophosphorylation-dependent protein kinase (auto-kinase) was identified from pig brain and liver on the basis of its unique autophosphorylation/activation property [Yang, Fong, Yu and Liu (1987) J. Biol. Chem. 262, 7034-7040; Yang, Chang and Soderling (1987) J. Biol. Chem. 262, 9421-9427]. Its substrate consensus sequence motif was determined as being -R-X-(X)-S*/T*-X3-S/T-. To characterize auto-kinase further, we partly sequenced the kinase purified from pig liver. The N-terminal sequence (VDGGAKTSDKQKKKAXMTDE) and two internal peptide sequences (EKLRTIV and LQNPEK/ILTP/FI) of auto-kinase were obtained. These sequences identify auto-kinase as a C-terminal catalytic fragment of p21-activated protein kinase 2 (PAK2 or gamma-PAK) lacking its N-terminal regulatory region. Auto-kinase can be recognized by an antibody raised against the C-terminal peptide of human PAK2 by immunoblotting. Furthermore the autophosphorylation site sequence of auto-kinase was successfully predicted on the basis of its substrate consensus sequence motif and the known PAK2 sequence, and was further demonstrated to be RST(P)MVGTPYWMAPEVVTR by phosphoamino acid analysis, manual Edman degradation and phosphopeptide mapping via the help of phosphorylation site analysis of a synthetic peptide corresponding to the sequence of PAK2 from residues 396 to 418. During the activation process, auto-kinase autophosphorylates mainly on a single threonine residue Thr402 (according to the sequence numbering of human PAK2). In addition, a phospho-specific antibody against a synthetic phosphopeptide containing this identified sequence was generated and shown to be able to differentially recognize the activated auto-kinase autophosphorylated at Thr402 but not the non-phosphorylated/inactive auto-kinase. Immunoblot analysis with this phospho-specific antibody further revealed that the change in phosphorylation level of Thr402 of auto-kinase was well correlated with the activity change of the kinase during both autophosphorylation/activation and protein phosphatase-mediated dephosphorylation/inactivation processes. Taken together, our results identify Thr402 as the regulatory autophosphorylation site of auto-kinase, which is a C-terminal catalytic fragment of PAK2.
Yu, J S; Chen, W J; Ni, M H; Chan, W H; Yang, S D
1998-01-01
Autophosphorylation-dependent protein kinase (auto-kinase) was identified from pig brain and liver on the basis of its unique autophosphorylation/activation property [Yang, Fong, Yu and Liu (1987) J. Biol. Chem. 262, 7034-7040; Yang, Chang and Soderling (1987) J. Biol. Chem. 262, 9421-9427]. Its substrate consensus sequence motif was determined as being -R-X-(X)-S*/T*-X3-S/T-. To characterize auto-kinase further, we partly sequenced the kinase purified from pig liver. The N-terminal sequence (VDGGAKTSDKQKKKAXMTDE) and two internal peptide sequences (EKLRTIV and LQNPEK/ILTP/FI) of auto-kinase were obtained. These sequences identify auto-kinase as a C-terminal catalytic fragment of p21-activated protein kinase 2 (PAK2 or gamma-PAK) lacking its N-terminal regulatory region. Auto-kinase can be recognized by an antibody raised against the C-terminal peptide of human PAK2 by immunoblotting. Furthermore the autophosphorylation site sequence of auto-kinase was successfully predicted on the basis of its substrate consensus sequence motif and the known PAK2 sequence, and was further demonstrated to be RST(P)MVGTPYWMAPEVVTR by phosphoamino acid analysis, manual Edman degradation and phosphopeptide mapping via the help of phosphorylation site analysis of a synthetic peptide corresponding to the sequence of PAK2 from residues 396 to 418. During the activation process, auto-kinase autophosphorylates mainly on a single threonine residue Thr402 (according to the sequence numbering of human PAK2). In addition, a phospho-specific antibody against a synthetic phosphopeptide containing this identified sequence was generated and shown to be able to differentially recognize the activated auto-kinase autophosphorylated at Thr402 but not the non-phosphorylated/inactive auto-kinase. Immunoblot analysis with this phospho-specific antibody further revealed that the change in phosphorylation level of Thr402 of auto-kinase was well correlated with the activity change of the kinase during both autophosphorylation/activation and protein phosphatase-mediated dephosphorylation/inactivation processes. Taken together, our results identify Thr402 as the regulatory autophosphorylation site of auto-kinase, which is a C-terminal catalytic fragment of PAK2. PMID:9693111
Park, R M
2001-04-01
To evaluate medical insurance claims for chronic disease investigation, claims from eight automotive machining plants (1984 to 1993) were linked with work histories (1967 to 1993), and associations with respiratory, cardiac, and cancer conditions were investigated, in a case-control design analyzed with logistic regression. The primary focus was tool grinding, but other important processes examined were metal-working, welding, forging, heat treat, engine testing, and diverse-skilled trades work. Considerable variability in claim-derived incidence rates across plants was not explained by age or known exposure differences. Asthma incidence increased in tool grinding (at mean cumulative duration: odds ratio [OR], 3.0; 95% confidence interval [CI], 0.90 to 10.0), as did non-ischemic heart disease (cardiomyopathy, cor pulmonale, rheumatic heart disease, or hypertension; OR, 3.1; 95% CI, 1.26 to 7.6). These trends appeared in models with deficits (OR < 1.0) for those ever exposed to tool grinding because of exposure-response miss-specification, demographic confounding, or removal of high-risk workers from the exposed group. The apparent cancer rates identified from claims greatly exceeded the expected rates from a cancer registry, suggesting that diagnostic, "rule-out," and surveillance functions were contributing. This study supports the epidemiologic use of medical insurance records in surveillance and, possibly, etiologic investigation and identifies issues requiring special attention or resolution.
Occupational Hydrofluoric Acid Injury from Car and Truck Washing--Washington State, 2001-2013.
Reeb-Whitaker, Carolyn K; Eckert, Carly M; Anderson, Naomi J; Bonauto, David K
2015-08-21
Exposure to hydrofluoric acid (HF) causes corrosive chemical burns and potentially fatal systemic toxicity. Car and truck wash cleaning products, rust removers, and aluminum brighteners often contain HF because it is efficient in breaking down roadway matter. The death of a truck wash worker from ingestion of an HF-based wash product and 48 occupational HF burn cases associated with car and truck washing in Washington State during 2001-2013 are summarized in this report. Among seven hospitalized workers, two required surgery, and all but one worker returned to the job. Among 48 injured workers, job titles were primarily auto detailer, car wash worker, truck wash worker, and truck driver. Because HF exposure can result in potentially severe health outcomes, efforts to identify less hazardous alternatives to HF-based industrial wash products are warranted.
NASA Technical Reports Server (NTRS)
Kanakia, M. D.; Switzer, W. G.; Hartzell, G. E.; Kaplan, H. L.
1980-01-01
Both materials possess a high degree of thermal stability, with total heat release values being essentially identical under piloted ignition conditions over a range of 5 to 10 W/sq cm incident heat flux. The graphite/epoxy material had a tendency to auto-ignite at a lower heat flux (about 7 W/sq cm) and produced about 23 percent higher peak heat release rates, approximately 42 percent more carbon monoxide and considerably more smoke than the graphite/bismaleimide under conditions of piloted ignition. Toxicological potencies of smoke produced from the two composites were equivalent for 30 minute exposures. Potencies were also comparable to many common materials, such as wood. There was no evidence for the formation of an "unusual toxicant" nor for any short term post-exposure toxicological effects.
Murbraech, Klaus; Wethal, Torgeir; Smeland, Knut B; Holte, Harald; Loge, Jon Håvard; Holte, Espen; Rösner, Assami; Dalen, Håvard; Kiserud, Cecilie E; Aakhus, Svend
2016-03-01
This study assessed the prevalence and associated risk factors for valvular dysfunction (VD) observed in adult lymphoma survivors (LS) after autologous hematopoietic stem cell transplantation (auto-HCT), and to determine whether anthracycline-containing chemotherapy (ACCT) alone in these patients is associated with VD. The prevalence of and risk factors for VD in LS after auto-HCT is unknown. Anthracyclines may induce heart failure, but any association with VD is not well-defined. This national cross-sectional study included all adult LS receiving auto-HCT from 1987 to 2008 in Norway. VD was defined by echocardiography as either more than mild regurgitation or any stenosis. Observations in LS were compared with a healthy age- and gender-matched (1:1) control group. In total, 274 LS (69% of all eligible) participated. Mean age was 56 ± 12 years, mean follow-up time after lymphoma diagnosis was 13 ± 6 years, and 62% of participants were males. Mean cumulative anthracycline dosage was 316 ± 111 mg/m(2), and 35% had received radiation therapy involving the heart (cardiac-RT). VD was observed in 22.3% of the LS. Severe VD was rare (n = 9; 3.3% of all LS) and mainly aortic stenosis (n = 7). We observed VD in 16.7% of LS treated with ACCT alone (n = 177), corresponding with a 3-fold increased VD risk (odds ratio: 2.9; 95% confidence interval: 1.5 to 5.8; p = 0.002) compared with controls. Furthermore, the presence of aortic valve degeneration was increased in the LS after ACCT alone compared with controls (13.0% vs. 2.9%; p < 0.001). Female sex, age >50 years at lymphoma diagnosis, ≥3 lines of chemotherapy before auto-HCT, and cardiac-RT >30 Gy were identified as independent risk factors for VD in the LS. In LS, ACCT alone was significantly associated with VD and related to valvular degeneration. Overall, predominantly moderate VD was prevalent in LS, and longer observation time is needed to clarify the clinical significance of this finding. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Analysis of Interactive Conflict Resolution Tool Usage in a Mixed Equipage Environment
NASA Technical Reports Server (NTRS)
Homola, Jeffrey; Morey, Susan; Cabrall, Christopher; Martin, Lynne; Mercer, Joey; Prevot, Thomas
2013-01-01
A human-in-the-loop simulation was conducted that examined separation assurance concepts in varying levels of traffic density with mixtures of aircraft equipage and automation. This paper's analysis focuses on one of the experimental conditions in which traffic levels were approximately fifty percent higher than today, and approximately fifty percent of the traffic within the test area were equipped with data communications (data comm) capabilities. The other fifty percent of the aircraft required control by voice much like today. Within this environment, the air traffic controller participants were provided access to tools and automation designed to support the primary task of separation assurance that are currently unavailable. Two tools were selected for analysis in this paper: 1) a pre-probed altitude fly-out menu that provided instant feedback of conflict probe results for a range of altitudes, and 2) an interactive auto resolver that provided on-demand access to an automation-generated conflict resolution trajectory. Although encouraged, use of the support tools was not required; the participants were free to use the tools as they saw fit, and they were also free to accept, reject, or modify the resolutions offered by the automation. This mode of interaction provided a unique opportunity to examine exactly when and how these tools were used, as well as how acceptable the resolutions were. Results showed that the participants used the pre-probed altitude fly-out menu in 14% of conflict cases and preferred to use it in a strategic timeframe on data comm equipped and level flight aircraft. The interactive auto resolver was also used in a primarily strategic timeframe on 22% of conflicts and that their preference was to use it on conflicts involving data comm equipped aircraft as well. Of the 258 resolutions displayed, 46% were implemented and 54% were not. The auto resolver was rated highly by participants in terms of confidence and preference. Factors such as aircraft equipage, ownership, and location of predicted separation loss appeared to play a role in the decision of controllers to accept or reject the auto resolver's resolutions.
Molecular mechanism of APC/C activation by mitotic phosphorylation.
Zhang, Suyang; Chang, Leifu; Alfieri, Claudio; Zhang, Ziguo; Yang, Jing; Maslen, Sarah; Skehel, Mark; Barford, David
2016-05-12
In eukaryotes, the anaphase-promoting complex (APC/C, also known as the cyclosome) regulates the ubiquitin-dependent proteolysis of specific cell-cycle proteins to coordinate chromosome segregation in mitosis and entry into the G1 phase. The catalytic activity of the APC/C and its ability to specify the destruction of particular proteins at different phases of the cell cycle are controlled by its interaction with two structurally related coactivator subunits, Cdc20 and Cdh1. Coactivators recognize substrate degrons, and enhance the affinity of the APC/C for its cognate E2 (refs 4-6). During mitosis, cyclin-dependent kinase (Cdk) and polo-like kinase (Plk) control Cdc20- and Cdh1-mediated activation of the APC/C. Hyperphosphorylation of APC/C subunits, notably Apc1 and Apc3, is required for Cdc20 to activate the APC/C, whereas phosphorylation of Cdh1 prevents its association with the APC/C. Since both coactivators associate with the APC/C through their common C-box and Ile-Arg tail motifs, the mechanism underlying this differential regulation is unclear, as is the role of specific APC/C phosphorylation sites. Here, using cryo-electron microscopy and biochemical analysis, we define the molecular basis of how phosphorylation of human APC/C allows for its control by Cdc20. An auto-inhibitory segment of Apc1 acts as a molecular switch that in apo unphosphorylated APC/C interacts with the C-box binding site and obstructs engagement of Cdc20. Phosphorylation of the auto-inhibitory segment displaces it from the C-box-binding site. Efficient phosphorylation of the auto-inhibitory segment, and thus relief of auto-inhibition, requires the recruitment of Cdk-cyclin in complex with a Cdk regulatory subunit (Cks) to a hyperphosphorylated loop of Apc3. We also find that the small-molecule inhibitor, tosyl-l-arginine methyl ester, preferentially suppresses APC/C(Cdc20) rather than APC/C(Cdh1), and interacts with the binding sites of both the C-box and Ile-Arg tail motifs. Our results reveal the mechanism for the regulation of mitotic APC/C by phosphorylation and provide a rationale for the development of selective inhibitors of this state.
The Relationship between Affective States and Dialog Patterns during Interactions with AutoTutor
ERIC Educational Resources Information Center
Graesser, Arthur C.; D'Mello, Sidney K.; Craig, Scotty D.; Witherspoon, Amy; Sullins, Jeremiah; McDaniel, Bethany; Gholson, Barry
2008-01-01
Relations between emotions (affect states) and learning have recently been explored in the context of AutoTutor. AutoTutor is a tutoring system on the Internet that helps learners construct answers to difficult questions by interacting with them in natural language. AutoTutor has an animated conversation agent and a dialog management facility that…
46 CFR 97.16-1 - Use of auto pilot.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Use of auto pilot. 97.16-1 Section 97.16-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Auto Pilot § 97.16-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
46 CFR 97.16-1 - Use of auto pilot.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Use of auto pilot. 97.16-1 Section 97.16-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Auto Pilot § 97.16-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
46 CFR 78.19-1 - Use of auto pilot.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 3 2012-10-01 2012-10-01 false Use of auto pilot. 78.19-1 Section 78.19-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Auto Pilot § 78.19-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used in— (a...
46 CFR 97.16-1 - Use of auto pilot.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Use of auto pilot. 97.16-1 Section 97.16-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Auto Pilot § 97.16-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
46 CFR 78.19-1 - Use of auto pilot.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 3 2014-10-01 2014-10-01 false Use of auto pilot. 78.19-1 Section 78.19-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Auto Pilot § 78.19-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used in— (a...
46 CFR 78.19-1 - Use of auto pilot.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 3 2013-10-01 2013-10-01 false Use of auto pilot. 78.19-1 Section 78.19-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Auto Pilot § 78.19-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used in— (a...
AutoTutor and Family: A Review of 17 Years of Natural Language Tutoring
ERIC Educational Resources Information Center
Nye, Benjamin D.; Graesser, Arthur C.; Hu, Xiangen
2014-01-01
AutoTutor is a natural language tutoring system that has produced learning gains across multiple domains (e.g., computer literacy, physics, critical thinking). In this paper, we review the development, key research findings, and systems that have evolved from AutoTutor. First, the rationale for developing AutoTutor is outlined and the advantages…
Electrical Systems. Auto Mechanics Curriculum Guide Module 2. Instructor's Guide.
ERIC Educational Resources Information Center
Hevel, David; Donovan, Roger
This document is one of a series of modules in the Missouri Auto Mechanics Curriculum Guide, which is based on 144 basic auto mechanics competencies identified on the Missouri Auto Mechanics Competency Profile. The instructor's materials in this document are for a 14-unit secondary education course. The following units are included: (1) principles…
Manual Drive Train and Axles. Auto Mechanics Curriculum Guide Module 7. Instructor's Guide.
ERIC Educational Resources Information Center
Colesworthy, Robert; Donovan, Roger
This document is one of a series of modules in the Missouri Auto Mechanics Curriculum Guide, which is based on 144 basic auto mechanics competencies identified on the Missouri Auto Mechanics Competency Profile. The instructor's materials in this document are for a 13-unit secondary education course. The following units are included: (1)…
46 CFR 97.16-1 - Use of auto pilot.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Use of auto pilot. 97.16-1 Section 97.16-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Auto Pilot § 97.16-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
46 CFR 78.19-1 - Use of auto pilot.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 3 2010-10-01 2010-10-01 false Use of auto pilot. 78.19-1 Section 78.19-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Auto Pilot § 78.19-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used in— (a...
77 FR 16227 - Frank Myers AutoMaxx, LLC; Analysis of Proposed Consent Order To Aid Public Comment
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-20
... FEDERAL TRADE COMMISSION [File No. 112 3206] Frank Myers AutoMaxx, LLC; Analysis of Proposed... ``Frank Myers AutoMaxx, File No. 112 3206'' on your comment, and file your comment online at https... April 16, 2012. Write ``Frank Myers AutoMaxx, File No. 112 3206'' on your comment. Your comment...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-25
... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-71,863] United Auto Workers Local... workers and former workers of United Auto Workers Local 1999, Oklahoma City, Oklahoma (the subject firm... Auto Workers Local 1999, Oklahoma City, Oklahoma, was based on the findings that the workers at the...
46 CFR 78.19-1 - Use of auto pilot.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 3 2011-10-01 2011-10-01 false Use of auto pilot. 78.19-1 Section 78.19-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Auto Pilot § 78.19-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used in— (a...
46 CFR 97.16-1 - Use of auto pilot.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Use of auto pilot. 97.16-1 Section 97.16-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Auto Pilot § 97.16-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
Fuzzy logic controllers: A knowledge-based system perspective
NASA Technical Reports Server (NTRS)
Bonissone, Piero P.
1993-01-01
Over the last few years we have seen an increasing number of applications of Fuzzy Logic Controllers. These applications range from the development of auto-focus cameras, to the control of subway trains, cranes, automobile subsystems (automatic transmissions), domestic appliances, and various consumer electronic products. In summary, we consider a Fuzzy Logic Controller to be a high level language with its local semantics, interpreter, and compiler, which enables us to quickly synthesize non-linear controllers for dynamic systems.
MM-wave cyclotron auto-resonance maser for plasma heating
NASA Astrophysics Data System (ADS)
Ceccuzzi, S.; Dattoli, G.; Di Palma, E.; Doria, A.; Gallerano, G. P.; Giovenale, E.; Mirizzi, F.; Spassovsky, I.; Ravera, G. L.; Surrenti, V.; Tuccillo, A. A.
2014-02-01
Heating and Current Drive systems are of outstanding relevance in fusion plasmas, magnetically confined in tokamak devices, as they provide the tools to reach, sustain and control burning conditions. Heating systems based on the electron cyclotron resonance (ECRH) have been extensively exploited on past and present machines DEMO, and the future reactor will require high frequencies. Therefore, high power (≥1MW) RF sources with output frequency in the 200 - 300 GHz range would be necessary. A promising source is the so called Cyclotron Auto-Resonance Maser (CARM). Preliminary results of the conceptual design of a CARM device for plasma heating, carried out at ENEA-Frascati will be presented together with the planned R&D development.
; margin-left: auto; margin-right: auto; } .slick-track:before, .slick-track:after { display: table : auto; border: 1px solid transparent; } .slick-arrow.slick-hidden { display: none;
Efficacy of dry-ice blasting in preventive maintenance of auto robotic assemblies
NASA Astrophysics Data System (ADS)
Baluch, Nazim; Mohtar, Shahimi; Abdullah, Che Sobry
2016-08-01
Welding robots are extensively applied in the automotive assemblies and `Spot Welding' is the most common welding application found in the auto stamping assembly manufacturing. Every manufacturing process is subject to variations - with resistance welding, these include; part fit up, part thickness variations, misaligned electrodes, variations in coating materials or thickness, sealers, weld force variations, shunting, machine tooling degradation; and slag and spatter damage. All welding gun tips undergo wear; an elemental part of the process. Though adaptive resistance welding control automatically compensates to keep production and quality up to the levels needed as gun tips undergo wear so that the welds remain reliable; the system cannot compensate for deterioration caused by the slag and spatter on the part holding fixtures, sensors, and gun tips. To cleanse welding robots of slag and spatter, dry-ice blasting has proven to be an effective remedy. This paper describes Spot welding process, analyses the slag and spatter formation during robotic welding of stamping assemblies, and concludes that the dry ice blasting process's utility in cleansing of welding robots in auto stamping plant operations is paramount and exigent.
Peng, Fei; Zhou, Xiao-Dong; Zhao, Kun; Wu, Zhi-Bo; Yang, Li-Zhong
2015-01-01
In this work, the effect of seven different sample orientations from 0° to 90° on pilot and non-pilot ignition of PMMA (poly(methyl methacrylate)) exposed to radiation has been studied with experimental and numerical methods. Some new and significant conclusions are drawn from the study, including a U-shape curve of ignition time and critical mass flux as sample angle increases for pilot ignition conditions. However, in auto-ignition, the ignition time and critical mass flux increases with sample angle α. Furthermore, a computational fluid dynamic model have been built based on the Fire Dynamics Simulator (FDS6) code to investigate the mechanisms controlling the dependence on sample orientation of the ignition of PMMA under external radiant heating. The results of theoretical analysis and modeling results indicate the decrease of total incident heat flux at sample surface plays the dominant role during the ignition processes of auto-ignition, but the volatiles gas flow has greater influence for piloted ignition conditions. PMID:28793421
Outcomes of autologous or allogeneic stem cell transplantation for non-Hodgkin lymphoma.
Reddy, Nishitha M; Oluwole, Olalekan; Greer, John P; Engelhardt, Brian G; Jagasia, Madan H; Savani, Bipin N
2014-01-01
Transplant outcomes of autologous or allogeneic stem cell transplantation (SCT) have not been elucidated as a single cohort in non-Hodgkin lymphoma (NHL). We analyzed the outcomes of 270 adult recipients receiving autologous (auto) SCT (n = 198) or allogeneic (allo) SCT (n = 72) for NHL between the years 2000 and 2010. Five-year overall survival rates for B and T cell NHL were 58% and 50%, respectively (allo-SCT 51% vs. 54% for B and T-cell NHL, and auto-SCT 60% vs. 47% for B and T cell lymphoma, respectively). In multivariate analysis, the number of chemotherapy regimens and disease status pre-SCT were independently associated with long-term outcome after SCT (for both auto- and allo-SCT). We conclude that the type of transplantation offered to patients, based on patient selection and disease-related factors, can achieve long-term survival, highlighting the importance of further improvement in disease control and reducing procedure-related mortality. The role of transplantation needs to be reevaluated in the era of targeted therapy. Copyright © 2014 ISEH - Society for Hematology and Stem Cells. All rights reserved.
Perri, Roberta; Turchetta, Chiara Stella; Caruso, Giulia; Fadda, Lucia; Caltagirone, Carlo; Carlesimo, Augusto Giovanni
2018-01-31
Apathy symptoms include different dimensions: cognitive (C), emotional-affective (E-Aff) and auto-activation; they have been related to dysfunctions of the dorsolateral, orbito-basal prefrontal cortex and the subcortical frontal connections to the basal ganglia, respectively. In Alzheimer's disease (AD), an association has been found between apathy severity and both executive deficits and atrophy of the dorso-lateral prefrontal cortex; however, it is not clear whether these associations concern only the cognitive aspects of apathy. Furthermore, whether there is an association in AD between E-aff apathy and theory of mind (ToM),the cognitive functions subsumed by the orbito-basal prefrontal cortex, has not been investigated. Aim of the study was to investigate the relationship between C, E-Aff and auto-activation apathy and performance on tasks investigating executive and ToM cognitive functions in AD. For this purpose, 20 AD patients with apathy and 20 matched controls were submitted to an executive and ToM neuropsychological assessment. Apathy was assessed with a weekly diary (ApD) created specifically to assist caregivers in quantifying the C, E-Aff and auto-activation symptomatology of apathy. Correlational analyses showed that AD patients' scores on the Modified Card Sorting Test (MCST) and Emotion Attribution tasks were correlated with most ApD scores. However, regression analyses showed that C diary scores were predicted by MCST performance, E-Aff diary scores by performance on the E-Attribution task and ApD scores measuring auto-activation apathy were predicted by both the MCST and the Emotion Attribution scores. These results confirm the co-occurrence of apathy and executive-function deficits in AD and suggest a specific association between AD patients' executive deficits and the cognitive component of apathy. Furthermore, they document, for the first time, an association between poor performance on tests assessing ToM abilities and the emotional-affective component of apathy in AD patients. Finally, these results are in line with the view that auto-activation apathy reflects the sum of emotional and cognitive processing deficits. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Jensen, J. B.; Schwenz, K.; Aquino, J.; Carnes, J.; Webster, C.; Munnerlyn, J.; Wissman, T.; Lugger, T.
2017-12-01
Giant sea-salt aerosol particles, also called Giant Cloud Condensation Nuclei (GCCN), have been proposed as a means of rapidly forming precipitation sized drizzle drops in warm marine clouds (e.g., Jensen and Nugent, 2017). Such rare particles are best sampled from aircraft in air below cloud base, where normal laser optical instruments have too low sample volume to give statistically significant samples of the large particle tail. An automated sampling system (the AutoGNI) has been built to operate from inside a pressurized aircraft. Under the aircraft floor, a pressurized vessel contains 32 custom-built polycarbonate microscope slides. Using robotics with 5 motor drives and 18 positioning switches, the AutoGNI can take slides from their holding cassettes, pass them onto a caddy in an airfoil that extends 200 mm outside the aircraft, where they are exposed in the free airstream, thus avoiding the usual problems with large particle losses in air intakes. Slides are typically exposed for 10-30 s in the marine boundary layer, giving sample volumes of about 100-300 L or more. Subsequently the slides are retracted into the pressure vessel, stored and transported for laboratory microscope image analysis, in order to derive size-distribution histograms. While the aircraft is flying, the AutoGNI system is remotely controlled from a laptop on the ground, using an encrypted commercial satellite connection to the NSF/NCAR GV research aircraft's main server, and onto the AutoGNI microprocessor. The sampling of such GCCN is becoming increasingly important in order to provide complete input data for model calculations of aerosol-cloud interactions and their feedbacks in climate prediction. The AutoGNI has so far been sampling sea-salt GCCN in the Magellan Straight during the 2016 ORCAS project and over the NW Pacific during the 2017 ARISTO project, both from the NSF/NCAR GV research aircraft. Sea-salt particle sizes of 1.4 - 32 μm dry diameter have been observed.
Clinical utility of anti-p53 auto-antibody: Systematic review and focus on colorectal cancer
Suppiah, Aravind; Greenman, John
2013-01-01
Mutation of the p53 gene is a key event in the carcinogenesis of many different types of tumours. These can occur throughout the length of the p53 gene. Anti-p53 auto-antibodies are commonly produced in response to these p53 mutations. This review firstly describes the various mechanisms of p53 dysfunction and their association with subsequent carcinogenesis. Following this, the mechanisms of induction of anti-p53 auto-antibody production are shown, with various hypotheses for the discrepancies between the presence of p53 mutation and the presence/absence of anti-p53 auto-antibodies. A systematic review was performed with a descriptive summary of key findings of each anti-p53 auto-antibody study in all cancers published in the last 30 years. Using this, the cumulative frequency of anti-p53 auto-antibody in each cancer type is calculated and then compared with the incidence of p53 mutation in each cancer to provide the largest sample calculation and correlation between mutation and anti-p53 auto-antibody published to date. Finally, the review focuses on the data of anti-p53 auto-antibody in colorectal cancer studies, and discusses future strategies including the potentially promising role using anti-p53 auto-antibody presence in screening and surveillance. PMID:23922463
Auto Body Welding 2 (Course Outline), Automotive Body Repair and Refinishing 1: 9033.04.
ERIC Educational Resources Information Center
Dade County Public Schools, Miami, FL.
The 90-hour course is a foundation quinmester course in welding for the auto body repairman. The outline consists of seven blocks of instruction (orientation, 6 hours; auto body oxyacetylene welding, 10 hours; electric arc welding equipment, 6 hours; auto body electric arc welding, 8 hours; position welding, 40 hours; electric spot welders, 16…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-07
...-AA87 Security Zone; 23rd Annual North American International Auto Show, Detroit River, Detroit, MI... officials at the 23rd Annual North American International Auto Show (NAIAS) being held at Cobo Hall in... 23rd Annual North American International Auto Show (NAIAS) being held at Cobo Hall in downtown Detroit...
A phase II study of V-BEAM as conditioning regimen before second auto-SCT for multiple myeloma.
Wang, T-F; Fiala, M A; Cashen, A F; Uy, G L; Abboud, C N; Fletcher, T; Wu, N; Westervelt, P; DiPersio, J F; Stockerl-Goldstein, K E; Vij, R
2014-11-01
High-dose melphalan has been the standard conditioning regimen for auto-SCT in multiple myeloma (MM) for decades. A more effective conditioning regimen may induce deeper responses and longer remission duration. It is especially needed in the setting of second auto-SCT, which rarely achieves comparable results with the first auto-SCT using the same conditioning regimen. Here we conducted a phase II study to investigate the efficacy and safety of a conditioning regimen V-BEAM (bortezomib-BEAM) before second auto-SCT for multiple myeloma. Ten patients were enrolled from September 2012 to May 2013. The CR rate at day +100 after auto-SCT was 75%; all except for one patient remained in remission after a median follow-up of 6 months. Three patients developed Clostridium difficile infection. Two patients died within the first 30 days of auto-SCT from neutropenic colitis and overwhelming sepsis, respectively. Due to the high rate of morbidity and mortality, the study was terminated after 10 patients. In summary, although the conditioning regimen V-BEAM before second auto-SCT for MM provided promising responses, it was associated with unexpected treatment-related toxicity and should not be investigated further without modifications.
What factors affect the carriage of epinephrine auto-injectors by teenagers?
Macadam, Clare; Barnett, Julie; Roberts, Graham; Stiefel, Gary; King, Rosemary; Erlewyn-Lajeunesse, Michel; Holloway, Judith A; Lucas, Jane S
2012-02-02
Teenagers with allergies are at particular risk of severe and fatal reactions, but epinephrine auto-injectors are not always carried as prescribed. We investigated barriers to carriage. Patients aged 12-18 years old under a specialist allergy clinic, who had previously been prescribed an auto-injector were invited to participate. Semi-structured interviews explored the factors that positively or negatively impacted on carriage. Twenty teenagers with food or venom allergies were interviewed. Only two patients had used their auto-injector in the community, although several had been treated for severe reactions in hospital. Most teenagers made complex risk assessments to determine whether to carry the auto-injector. Most but not all decisions were rational and were at least partially informed by knowledge. Factors affecting carriage included location, who else would be present, the attitudes of others and physical features of the auto-injector. Teenagers made frequent risk assessments when deciding whether to carry their auto-injectors, and generally wanted to remain safe. Their decisions were complex, multi-faceted and highly individualised. Rather than aiming for 100% carriage of auto-injectors, which remains an ambitious ideal, personalised education packages should aim to empower teenagers to make and act upon informed risk assessments.
Auto-immune hepatitis following delivery.
Saini, Vandana; Gupta, Mamta; Mishra, S K
2013-05-01
Auto-immune hepatitis first presenting in the early postpartum period is rare. Immunosuppressive effects of pregnancy result in delayed manifestation of auto-immune hepatitis, and in established cases, the spontaneous improvements are there. Auto-immune hepatitis should be considered in the differential diagnosis of liver dysfunction first presenting in the early postpartum period. A case of postpartum hepatitis of auto-immune aetiology is being presented here. It is disease of unknown aetiology, characterised by inflammation of liver (as evidenced by raised serum transaminases, presence of interface hepatitis on histological examination), hypergammaglobulinaemia (> 1.5 times normal), presence of auto-antibodies [(antinuclear antibodies (ANA)], smooth muscle antibody (SMA) and antibody to liver-kidney microsome type 1 (LKM1) in the absence of viral markers ie, hepatitis B (HBsAg) and C (AntiHCV) and excellent response to corticosteroid therapy.
The “Auto-Dissemination” Approach: A Novel Concept to Fight Aedes albopictus in Urban Areas
Caputo, Beniamino; Ienco, Annamaria; Cianci, Daniela; Pombi, Marco; Petrarca, Vincenzo; Baseggio, Alberto; Devine, Gregor J.; della Torre, Alessandra
2012-01-01
Background The main constraint to the fight against container-breeding mosquito vectors of human arboviruses is the difficulty in targeting the multiplicity of larval sources, mostly represented by small man-made water containers. The aim of this work is to assess the feasibility of the “auto-dissemination” approach, already tested for Aedes aegypti, as a possible alternative to traditional, inefficient control tools, against Ae. albopictus in urban areas. The approach is based on the possibility that wild adult females, exposed to artificial resting sites contaminated with pyriproxyfen, can disseminate this juvenile hormone analogue to larval habitats, thus interfering with adult emergence. Methodology We carried out four field experiments in two areas of Rome that are typically highly infested with Ae. albopictus, i.e. the main cemetery and a small green area within a highly urbanised neighbourhood. In each area we used 10 pyriproxyfen “dissemination” stations, 10 “sentinel” sites and 10 covered, control sites. The sentinel and control sites each contained 25 Ae. albopictus larvae. These were monitored for development and adult emergence. Principal Findings When a 5% pyriproxyfen powder was used to contaminate the dissemination sites, we observed significantly higher mortality at the pupal stage in the sentinel sites (50–70%) than in the controls (<2%), showing that pyriproxyfen was transferred by mosquitoes into sentinel sites and that it had a lethal effect. Conclusions The results support the potential feasibility of the auto-dissemination approach to control Ae. albopictus in urban areas. Further studies will be carried out to optimize the method and provide an effective tool to reduce the biting nuisance caused by this aggressive species and the transmission risk of diseases such as Dengue and Chikungunya. These arboviruses pose an increasing threat in Europe as Ae. albopictus expands its range. PMID:22953015
A Co-Adaptive Brain-Computer Interface for End Users with Severe Motor Impairment
Faller, Josef; Scherer, Reinhold; Costa, Ursula; Opisso, Eloy; Medina, Josep; Müller-Putz, Gernot R.
2014-01-01
Co-adaptive training paradigms for event-related desynchronization (ERD) based brain-computer interfaces (BCI) have proven effective for healthy users. As of yet, it is not clear whether co-adaptive training paradigms can also benefit users with severe motor impairment. The primary goal of our paper was to evaluate a novel cue-guided, co-adaptive BCI training paradigm with severely impaired volunteers. The co-adaptive BCI supports a non-control state, which is an important step toward intuitive, self-paced control. A secondary aim was to have the same participants operate a specifically designed self-paced BCI training paradigm based on the auto-calibrated classifier. The co-adaptive BCI analyzed the electroencephalogram from three bipolar derivations (C3, Cz, and C4) online, while the 22 end users alternately performed right hand movement imagery (MI), left hand MI and relax with eyes open (non-control state). After less than five minutes, the BCI auto-calibrated and proceeded to provide visual feedback for the MI task that could be classified better against the non-control state. The BCI continued to regularly recalibrate. In every calibration step, the system performed trial-based outlier rejection and trained a linear discriminant analysis classifier based on one auto-selected logarithmic band-power feature. In 24 minutes of training, the co-adaptive BCI worked significantly (p = 0.01) better than chance for 18 of 22 end users. The self-paced BCI training paradigm worked significantly (p = 0.01) better than chance in 11 of 20 end users. The presented co-adaptive BCI complements existing approaches in that it supports a non-control state, requires very little setup time, requires no BCI expert and works online based on only two electrodes. The preliminary results from the self-paced BCI paradigm compare favorably to previous studies and the collected data will allow to further improve self-paced BCI systems for disabled users. PMID:25014055
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piette, Mary Ann; Sezgen, Osman; Watson, David S.
This report describes the results of a research project to develop and evaluate the performance of new Automated Demand Response (Auto-DR) hardware and software technology in large facilities. Demand Response (DR) is a set of activities to reduce or shift electricity use to improve electric grid reliability, manage electricity costs, and ensure that customers receive signals that encourage load reduction during times when the electric grid is near its capacity. The two main drivers for widespread demand responsiveness are the prevention of future electricity crises and the reduction of electricity prices. Additional goals for price responsiveness include equity through costmore » of service pricing, and customer control of electricity usage and bills. The technology developed and evaluated in this report could be used to support numerous forms of DR programs and tariffs. For the purpose of this report, we have defined three levels of Demand Response automation. Manual Demand Response involves manually turning off lights or equipment; this can be a labor-intensive approach. Semi-Automated Response involves the use of building energy management control systems for load shedding, where a preprogrammed load shedding strategy is initiated by facilities staff. Fully-Automated Demand Response is initiated at a building or facility through receipt of an external communications signal--facility staff set up a pre-programmed load shedding strategy which is automatically initiated by the system without the need for human intervention. We have defined this approach to be Auto-DR. An important concept in Auto-DR is that a facility manager is able to ''opt out'' or ''override'' an individual DR event if it occurs at a time when the reduction in end-use services is not desirable. This project sought to improve the feasibility and nature of Auto-DR strategies in large facilities. The research focused on technology development, testing, characterization, and evaluation relating to Auto-DR. This evaluation also included the related decisionmaking perspectives of the facility owners and managers. Another goal of this project was to develop and test a real-time signal for automated demand response that provided a common communication infrastructure for diverse facilities. The six facilities recruited for this project were selected from the facilities that received CEC funds for new DR technology during California's 2000-2001 electricity crises (AB970 and SB-5X).« less
78 FR 57675 - Notice of Passenger Facility Charge Approvals and Disapprovals
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-19
... carrier and general aviation apron rehabilitation--design. Air carrier and general aviation apron rehabilitation--design reimbursement. Air carrier and general aviation apron rehabilitation--construction. Rehabilitate and expand auto parking lot--design. Airfield lighting control--design. Aircraft rescue and...
ERIC Educational Resources Information Center
Lefebre-Pinard, Monique
1983-01-01
Presents an integrated view of contributions made by various sections within cognitive psychology in which problems of consciousness are addressed. Implications concerning the relationship between cognition and behavior are pointed out. (Author/RH)
A Needs Assessment of Entry-Level Competencies for Modification of an Auto Body Repair Curriculum.
ERIC Educational Resources Information Center
Borremans, Robert T.
A needs assessment was conducted to determine job tasks relevant for entry-level auto body repairers as a basis for updating the Auto Body Program at Blackhawk Technical Institute (BTI). A survey was mailed to 86 local auto body shops, asking employers to rank 149 tasks in 11 duty areas in terms of importance and frequency performed. Study…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-05
... has executed on average per trading day (excluding partial trading days) in AutoEx or Order Delivery... (``AutoEx'') shall mean only those executed shares of the ETP Holder that are submitted in AutoEx mode... period, a combined ADV in both AutoEx and Order Delivery of at least 11.5 million shares, of which at...
Incidence of auto-immune pemphigus in the Midi-Pyrénées region in 2002-2006.
Thomas, M; Paul, C; Berard, E; Fortenfant, F; Mazereeuw-Hautier, J; Livideanu, C; Viraben, R; Meyer, N
2010-01-01
Auto-immune pemphigus is an organ-specific immune disorder due to pathogenic auto-antibodies. Both genetic and environmental factors have been associated with the occurrence of auto-immune pemphigus. Little is known about the epidemiology of auto-immune pemphigus in western Europe. To evaluate the incidence of auto-immune pemphigus in south-western France (namely the Midi-Pyrénées region) in a 5-year period between 2002 and 2006. We performed a retrospective study of the annual incidence of auto-immune pemphigus diagnosed in the Midi-Pyrénées region, between January 1, 2002, and December 31, 2006. Possible cases of pemphigus were initially selected using skin direct immunofluorescence (DIF) databases from all laboratories in the Midi-Pyrénées region. Systematic validation of all cases was performed by two of the authors (N.M., M.T.). To qualify as a case of auto-immune pemphigus, patients had to fulfil the following criteria: history of clinical signs of pemphigus as assessed by a dermatologist and a positive DIF. To be included in the study, validated cases of auto-immune pemphigus had to fulfil the following criteria: the date of first positive skin DIF between January 1, 2002, and December 31, 2006, and patient living in the Midi-Pyrénées region at the time of the first positive skin DIF. Between 2002 and 2006, 91 patients with positive DIF were identified. Fifty-four patients with positive DIF did not meet the validation criteria for the study. Thirty-seven cases were included in the analysis. The crude annual mean incidence of auto-immune pemphigus between 2002 and 2006 was 2.7 cases/10(6) inhabitants/year (95% CI: 1.87-3.69). The world-population-standardized annual mean incidence of auto-immune pemphigus was 1.55 (95% CI: 0.99-2.11). We report a 1.55/10(6) inhabitants/year world-population-standardized incidence of auto-immune pemphigus in the south-west of France. A nationwide epidemiological study of pemphigus should be performed in France.
Stitching-aware in-design DPT auto fixing for sub-20nm logic devices
NASA Astrophysics Data System (ADS)
Choi, Soo-Han; Sai Krishna, K. V. V. S.; Pemberton-Smith, David
2017-03-01
As the technology continues to shrink below 20nm, Double Patterning Technology (DPT) becomes one of the mandatory solutions for routing metal layers. From the view point of Place and Route (P&R), the major concerns are how to prevent DPT odd-cycles automatically without sacrificing chip area. Even though the leading-edge P&R tools have advanced algorithms to prevent DPT odd-cycles, it is very hard to prevent the localized DPT odd-cycles, especially in Engineering Change Order (ECO) routing. In the last several years, we developed In-design DPT Auto Fixing method in order to reduce localized DPT odd-cycles significantly during ECO and could achieve remarkable design Turn-Around Times (TATs). But subsequently, as the design complexity continued increasing and chip size continued decreasing, we needed a new In-design DPT Auto Fixing approach to improve the auto. fixing rate. In this paper, we present the Stitching-Aware In-design DPT Auto Fixing method for better fixing rates and smaller chip design. The previous In-design DPT Auto Fixing method detected all DPT odd-cycles and tried to remove oddcycles by increasing the adjacent space. As the metal congestions increase in the newer technology nodes, the older Auto Fixing method has limitations to increase the adjacent space between routing metals. Consequently, the auto fixing rate of older method gets worse with the introduction of the smaller design rules. With DPT stitching enablement at In-design DRC checking procedure, the new Stitching-Aware DPT Auto Fixing method detects the most critical odd-cycles and revolve the odd-cycles automatically. The accuracy of new flow ensures better usage of space in the congested areas, and helps design more smaller chips. By applying the Stitching-Aware DPT Auto Fixing method to sub-20nm logic devices, we can confirm that the auto fixing rate is improved by 2X compared with auto fixing without stitching. Additionally, by developing the better heuristic algorithm and flow for DPT stitching, we can get DPT compliant layout with the acceptable design TATs.
Luo, Jiin-Chyuan John; Hsu, Kuang-Hung; Shen, Wu-Shiun
2006-06-01
Spot or resistance welding has been considered less hazardous than other types of welding. Automobile manufacturing is a major industry in Taiwan. Spot and arc welding are common processes in this industry. The respiratory effects on automobile spot welders exposed to metal fumes are investigated. The cohort consisted of 41 male auto-body spot welders, 76 male arc welders, 71 male office workers, and 59 assemblers without welding exposure. Inductivity Coupled Plasma Mass Spectrophotometer (ICP-MS) was applied to detect metals' (zinc, copper, nickel) levels in the post-shift urine samples. Demographic data, work history, smoking status, and respiratory tract irritation symptoms were gathered by a standard self-administered questionnaire. Pulmonary function tests were also performed. There were significantly higher values for average urine metals' (zinc, copper, nickel) levels in spot welders and arc welders than in the non-welding controls. There were 4 out of 23 (17.4%) abnormal forced vital capacity (FVC) among the high-exposed spot welders, 2 out of 18 (11.1%) among the low-exposed spot welders, and 6 out of 130 (4.6%) non-welding-exposed workers. There was a significant linear trend between spot welding exposure and the prevalence of restrictive airway abnormalities (P = 0.036) after adjusting for other factors. There were 9 out of 23 (39.1%) abnormal peak expiratory flow rate (PEFR) among high-exposed spot welders, 5 out of 18 (27.8%) among the low-exposed spot welders, and 28 out of 130 (21.5%) non-welding-exposed workers. There was a borderline significant linear trend between spot welding exposure and the prevalence of obstructive lung function abnormalities (P = 0.084) after adjusting for other factors. There was also a significant dose-response relationship of airway irritation symptoms (cough, phlegm, chronic bronchitis) among the spot welders. Arc welders with high exposure status also had a significant risk of obstructive lung abnormalities (PEFR reduction). There was also a significant dose-response relationship of airway irritation symptoms (cough, phlegm, chest tightness, and chronic bronchitis) among the arc welders. These findings suggest that restrictive and obstructive lung abnormalities, and airway irritation symptoms are associated with spot and arc welding exposures.
Double-lumen tubes and auto-PEEP during one-lung ventilation.
Spaeth, J; Ott, M; Karzai, W; Grimm, A; Wirth, S; Schumann, S; Loop, T
2016-01-01
Double-lumen tubes (DLT) are routinely used to enable one-lung-ventilation (OLV) during thoracic anaesthesia. The flow-dependent resistance of the DLT's bronchial limb may be high as a result of its narrow inner diameter and length, and thus potentially contribute to an unintended increase in positive end-expiratory pressure (auto-PEEP). We therefore studied the impact of adult sized DLTs on the dynamic auto-PEEP during OLV. In this prospective clinical study, dynamic auto-PEEP was determined in 72 patients undergoing thoracic surgery, with right- and left-sided DLTs of various sizes. During OLV, air trapping was provoked by increasing inspiration to expiration ratio from 1:2 to 2:1 (five steps). Based on measured flow rate, airway pressure (Paw) and bronchial pressure (Pbronch), the pressure gradient across the DLT (ΔPDLT) and the total auto-PEEP in the respiratory system (i.e. the lungs, the DLT and the ventilator circuit) were determined. Subsequently the DLT's share in total auto-PEEP was calculated. ΔPDLT was 2.3 (0.7) cm H2O over the entire breathing cycle. At the shortest expiratory time the mean total auto-PEEP was 2.9 (1.5) cm H2O (range 0-5.9 cm H2O). The DLT caused 27 to 31% of the total auto-PEEP. Size and side of the DLT's bronchial limb did not impact auto-PEEP significantly. Although the DLT contributes to the overall auto-PEEP, its contribution is small and independent of size and side of the DLT's bronchial limb. The choice of DLT does not influence the risk of auto-PEEP during OLV to a clinically relevant extent. DRKS00005648. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Nigro, Carlos Alberto; González, Sergio; Arce, Anabella; Aragone, María Rosario; Nigro, Luciana
2015-05-01
Patients under treatment with continuous positive airway pressure (CPAP) may have residual sleep apnea (RSA). The main objective of our study was to evaluate a novel auto-CPAP for the diagnosis of RSA. All patients referred to the sleep laboratory to undergo CPAP polysomnography were evaluated. Patients treated with oxygen or noninvasive ventilation and split-night polysomnography (PSG), PSG with artifacts, or total sleep time less than 180 min were excluded. The PSG was manually analyzed before generating the automatic report from auto-CPAP. PSG variables (respiratory disturbance index (RDI), obstructive apnea index, hypopnea index, and central apnea index) were compared with their counterparts from auto-CPAP through Bland-Altman plots and intraclass correlation coefficient. The diagnostic accuracy of autoscoring from auto-CPAP using different cutoff points of RDI (≥5 and 10) was evaluated by the receiver operating characteristics (ROCs) curve. The study included 114 patients (24 women; mean age and BMI, 59 years old and 33 kg/m(2); RDI and apnea/hypopnea index (AHI)-auto median, 5 and 2, respectively). The average difference between the AHI-auto and the RDI was -3.5 ± 3.9. The intraclass correlation coefficient (ICC) between the total number of central apneas, obstructive, and hypopneas between the PSG and the auto-CPAP were 0.69, 0.16, and 0.15, respectively. An AHI-auto >2 (RDI ≥ 5) or >4 (RDI ≥ 10) had an area under the ROC curve, sensitivity, specificity, positive likelihood ratio, and negative for diagnosis of residual sleep apnea of 0.84/0.89, 84/81%, 82/91%, 4.5/9.5, and 0.22/0.2, respectively. The automatic analysis from auto-CPAP (S9 Autoset) showed a good diagnostic accuracy to identify residual sleep apnea. The absolute agreement between PSG and auto-CPAP to classify the respiratory events correctly varied from very low (obstructive apneas, hypopneas) to moderate (central apneas).
2017-01-01
With the aim to investigate the outcome of tandem high-dose chemotherapy and autologous stem cell transplantation (HDCT/auto-SCT) for high-grade gliomas (HGGs), we retrospectively reviewed the medical records of 30 patients with HGGs (16 glioblastomas, 7 anaplastic astrocytomas, and 7 other HGGs) between 2006 and 2015. Gross or near total resection was possible in 11 patients. Front-line treatment after surgery was radiotherapy (RT) in 14 patients and chemotherapy in the remaining 16 patients including 3 patients less than 3 years of age. Eight of 12 patients who remained progression free and 5 of the remaining 18 patients who experienced progression during induction treatment underwent the first HDCT/auto-SCT with carboplatin + thiotepa + etoposide (CTE) regimen and 11 of them proceeded to the second HDCT/auto-SCT with cyclophosphamide + melphalan (CyM) regimen. One patient died from hepatic veno-occlusive disease (VOD) during the second HDCT/auto-SCT; otherwise, toxicities were manageable. Four patients in complete response (CR) and 3 of 7 patients in partial response (PR) or second PR at the first HDCT/auto-SCT remained event free: however, 2 patients with progressive tumor experienced progression again. The probabilities of 3-year overall survival (OS) after the first HDCT/auto-SCT in 11 patients in CR, PR, or second PR was 58.2% ± 16.9%. Tumor status at the first HDCT/auto-SCT was the only significant factor for outcome after HDCT/auto-SCT. There was no difference in survival between glioblastoma and other HGGs. This study suggests that the outcome of HGGs in children and adolescents after HDCT/auto-SCT is encouraging if the patient could achieve CR or PR before HDCT/auto-SCT. PMID:28049229
Post-autologous transplant maintenance therapies in lymphoid malignancies: are we there yet?
Epperla, N; Fenske, T S; Lazarus, H M; Hamadani, M
2015-11-01
Disease relapse after autologous hematopoietic transplant (auto-HCT) remains the number one cause of post-transplant therapy failure and mortality. The last decade has seen a proliferation of clinical studies looking at the prevention of post-auto-HCT therapy failure with various maintenance strategies. The benefit of such therapies is in turn dependent on disease histology and timing of transplantation. Although high dose therapy (HDT) provides durable responses in chemosensitive relapsed diffuse large B-cell lymphoma (DLBCL), a sizable subset experiences disease relapse. Unfortunately, the addition of rituximab as a post-auto-HCT maintenance strategy did not improve survival outcomes. The preliminary results with programmed death -1 (PD-1) Ab as post-auto maintenance in DLBCL is promising but requires randomized validation. In follicular lymphoma, the 5- and 10-year PFS rates are ~60% and 31%, respectively. Although the addition of rituximab improved PFS, there is no survival benefit, to date. Disease relapse after auto-HCT in mantle cell lymphoma (MCL) is not uncommon. Rituximab maintenance in this setting provides a PFS benefit. Given the poor prognosis of post-auto-HCT failures in MCL, maintenance can be considered on a case-by-case basis. In chemosensitive relapsed Hodgkin lymphoma, addition of brentuximab vedotin after auto-HCT improved 2-year PFS (65 vs 45%) and can be considered as an option for maintenance therapy post auto-HCT, in select higher risk patients. Ongoing trials evaluating the efficacy of post-auto-HCT maintenance with novel agents (for example, immunomodulators, proteasome inhibitors, PD-1 inhibitors, Bruton's tyrosine kinase inhibitors and so on) will likely change the practice landscape for lymphoma patients following HDT and auto-HCT.
Impact of single-site axonal GABAergic synaptic events on cerebellar interneuron activity.
de San Martin, Javier Zorrilla; Jalil, Abdelali; Trigo, Federico F
2015-12-01
Axonal ionotropic receptors are present in a variety of neuronal types, and their function has largely been associated with the modulation of axonal activity and synaptic release. It is usually assumed that activation of axonal GABA(A)Rs comes from spillover, but in cerebellar molecular layer interneurons (MLIs) the GABA source is different: in these cells, GABA release activates presynaptic GABA(A) autoreceptors (autoRs) together with postsynaptic targets, producing an autoR-mediated synaptic event. The frequency of presynaptic, autoR-mediated miniature currents is twice that of their somatodendritic counterparts, suggesting that autoR-mediated responses have an important effect on interneuron activity. Here, we used local Ca(2+) photolysis in MLI axons of juvenile rats to evoke GABA release from individual varicosities to study the activation of axonal autoRs in single release sites. Our data show that single-site autoR conductances are similar to postsynaptic dendritic conductances. In conditions of high [Cl(-)](i), autoR-mediated conductances range from 1 to 5 nS; this corresponds to ∼30-150 GABA(A) channels per presynaptic varicosity, a value close to the number of channels in postsynaptic densities. Voltage responses produced by the activation of autoRs in single varicosities are amplified by a Na(v)-dependent mechanism and propagate along the axon with a length constant of 91 µm. Immunolabeling determination of synapse location shows that on average, one third of the synapses produce autoR-mediated signals that are large enough to reach the axon initial segment. Finally, we show that single-site activation of presynaptic GABA(A) autoRs leads to an increase in MLI excitability and thus conveys a strong feedback signal that contributes to spiking activity. © 2015 Zorrilla de San Martin et al.
Impact of single-site axonal GABAergic synaptic events on cerebellar interneuron activity
Zorrilla de San Martin, Javier; Jalil, Abdelali
2015-01-01
Axonal ionotropic receptors are present in a variety of neuronal types, and their function has largely been associated with the modulation of axonal activity and synaptic release. It is usually assumed that activation of axonal GABAARs comes from spillover, but in cerebellar molecular layer interneurons (MLIs) the GABA source is different: in these cells, GABA release activates presynaptic GABAA autoreceptors (autoRs) together with postsynaptic targets, producing an autoR-mediated synaptic event. The frequency of presynaptic, autoR-mediated miniature currents is twice that of their somatodendritic counterparts, suggesting that autoR-mediated responses have an important effect on interneuron activity. Here, we used local Ca2+ photolysis in MLI axons of juvenile rats to evoke GABA release from individual varicosities to study the activation of axonal autoRs in single release sites. Our data show that single-site autoR conductances are similar to postsynaptic dendritic conductances. In conditions of high [Cl−]i, autoR-mediated conductances range from 1 to 5 nS; this corresponds to ∼30–150 GABAA channels per presynaptic varicosity, a value close to the number of channels in postsynaptic densities. Voltage responses produced by the activation of autoRs in single varicosities are amplified by a Nav-dependent mechanism and propagate along the axon with a length constant of 91 µm. Immunolabeling determination of synapse location shows that on average, one third of the synapses produce autoR-mediated signals that are large enough to reach the axon initial segment. Finally, we show that single-site activation of presynaptic GABAA autoRs leads to an increase in MLI excitability and thus conveys a strong feedback signal that contributes to spiking activity. PMID:26621773
Erdemir, A; Eldeniz, A U; Ari, H; Belli, S; Esener, T
2007-05-01
To determine the influence of various irrigating solutions on the accuracy of the electronic apex locator facility in the Tri Auto ZX handpiece. One hundred and forty teeth with single canals and mature apices, scheduled for extraction for either periodontal or prosthetic reasons in 76 patients were used. Following informed written consent local anaesthesia was administered, access cavities were prepared and pulp tissue removed. The teeth were then randomly divided into seven groups according to the irrigating solutions used. The root canal length measurements were completed using the Tri Auto ZX handpiece with automatic reverse function in the presence of one or other of the following solutions: 0.9% saline, 2.5% NaOCl, 3% H(2)O(2), 0.2% chlorhexidine, 17% EDTA, Ultracaine D-S or in the absence of an irrigating solution (control). Files were immobilized in the access cavity with composite resin. After extraction, the apical regions of the teeth were exposed and the file tips examined under a stereomicroscope. Distances between the file tips and the apical constriction were measured (mm) and analysed using a one-way anova and post hoc Tukey test. Mean distances from the apical constriction to the file tip were longer in the 0.9% saline group (P<0.05). There was no statistically significant difference on file tip position between the other solutions. Tri Auto ZX gave reliable results with all irrigating solutions apart from in the presence of 0.9% saline.
[Auto-immune disorders as a possible cause of neuropsychiatric syndromes].
Martinez-Martinez, P; Molenaar, P C; Losen, M; Hoffmann, C; Stevens, J; de Witte, L D; van Amelsvoort, T; van Os, J; Rutten, B P F
2015-01-01
Changes that occur in the behaviour of voltage-gated ion channels and ligand-gated receptor channels due to gene mutations or auto-immune attack are the cause of channelopathies in the central and peripheral nervous system. Although the relation between molecular channel defects and clinical symptoms has been explained in the case of many neuromuscular channelopathies, the pathophysiology of auto-immunity in neuropsychiatric syndromes is still unclear. To review recent findings regarding neuronal auto-immune reactions in severe neuropsychiatric syndromes. Using PubMed, we consulted the literature published between 1990 and August 2014 relating to the occurrence of auto-immune antibodies in severe and persistent neuropsychiatric syndromes. Auto-antibodies have only limited access to the central nervous system, but if they do enter the system they can, in some cases, cause disease. We discuss recent findings regarding the occurrence of auto-antibodies against ligand-activated receptor channels and potassium channels in neuropsychiatric and neurological syndromes, including schizophrenia and limbic encephalitis. Although the occurrence of several auto-antibodies in schizophrenia has been confirmed, there is still no proof of a causal relationship in the syndrome. We still have no evidence of the prevalence of auto-immunity in neuropsychiatric syndromes. The discovery that an antibody against an ion channel is associated with some neuropsychiatric disorders may mean that in future it will be possible to treat patients by means of immunosuppression, which could lead to an improvement in a patient's cognitive abilities.
2012-01-01
Background Arsenic is a natural drinking water contaminant affecting 26 million people in West Bengal, India. Chronic arsenic exposure causes cancer, cardiovascular disease, liver disease, neuropathies and ocular diseases. The aims of the present study were to assess bioindicators of hepatocellular injury as indicated by the levels of liver enzymes, to determine the auto immune status, as indicated by the amounts of anti-nuclear antibodies (ANA) and anti-dsDNA antibodies in their serum, and to predict cardiovascular risk in the arsenic exposed population. Methods Effect of chronic arsenic exposure on liver was determined by liver function tests. Autoimmune status was measured by measuring ANA and anti-dsDNA in serum. Inflammatory cytokines associated with increased cardiovascular disease risk, IL6, IL8 and MCP-1 were determined. Results Our results indicated that serum levels of bilirubin, alanine transaminase, aspartate transaminase, alkaline phosphatase and ANA were increased in the arsenic exposed population. Serum levels of IL6 and IL8 also increased in the arsenic exposed group. Conclusions Chronic arsenic exposure causes liver injury, increases the serum levels of autoimmune markers and imparts increased cardiovascular risk. PMID:22883023
Preliminary Full-Scale Tests of the Center for Automated Processing of Hardwoods' Auto-Image
Philip A. Araman; Janice K. Wiedenbeck
1995-01-01
Automated lumber grading and yield optimization using computer controlled saws will be plausible for hardwoods if and when lumber scanning systems can reliably identify all defects by type. Existing computer programs could then be used to grade the lumber, identify the best cut-up solution, and control the sawing machines. The potential value of a scanning grading...
Polarization Imaging Apparatus with Auto-Calibration
NASA Technical Reports Server (NTRS)
Zou, Yingyin Kevin (Inventor); Zhao, Hongzhi (Inventor); Chen, Qiushui (Inventor)
2013-01-01
A polarization imaging apparatus measures the Stokes image of a sample. The apparatus consists of an optical lens set, a first variable phase retarder (VPR) with its optical axis aligned 22.5 deg, a second variable phase retarder with its optical axis aligned 45 deg, a linear polarizer, a imaging sensor for sensing the intensity images of the sample, a controller and a computer. Two variable phase retarders were controlled independently by a computer through a controller unit which generates a sequential of voltages to control the phase retardations of the first and second variable phase retarders. A auto-calibration procedure was incorporated into the polarization imaging apparatus to correct the misalignment of first and second VPRs, as well as the half-wave voltage of the VPRs. A set of four intensity images, I(sub 0), I(sub 1), I(sub 2) and I(sub 3) of the sample were captured by imaging sensor when the phase retardations of VPRs were set at (0,0), (pi,0), (pi,pi) and (pi/2,pi), respectively. Then four Stokes components of a Stokes image, S(sub 0), S(sub 1), S(sub 2) and S(sub 3) were calculated using the four intensity images.
Polarization imaging apparatus with auto-calibration
Zou, Yingyin Kevin; Zhao, Hongzhi; Chen, Qiushui
2013-08-20
A polarization imaging apparatus measures the Stokes image of a sample. The apparatus consists of an optical lens set, a first variable phase retarder (VPR) with its optical axis aligned 22.5.degree., a second variable phase retarder with its optical axis aligned 45.degree., a linear polarizer, a imaging sensor for sensing the intensity images of the sample, a controller and a computer. Two variable phase retarders were controlled independently by a computer through a controller unit which generates a sequential of voltages to control the phase retardations of the first and second variable phase retarders. A auto-calibration procedure was incorporated into the polarization imaging apparatus to correct the misalignment of first and second VPRs, as well as the half-wave voltage of the VPRs. A set of four intensity images, I.sub.0, I.sub.1, I.sub.2 and I.sub.3 of the sample were captured by imaging sensor when the phase retardations of VPRs were set at (0,0), (.pi.,0), (.pi.,.pi.) and (.pi./2,.pi.), respectively. Then four Stokes components of a Stokes image, S.sub.0, S.sub.1, S.sub.2 and S.sub.3 were calculated using the four intensity images.
What factors affect the carriage of epinephrine auto-injectors by teenagers?
2012-01-01
Background Teenagers with allergies are at particular risk of severe and fatal reactions, but epinephrine auto-injectors are not always carried as prescribed. We investigated barriers to carriage. Methods Patients aged 12-18 years old under a specialist allergy clinic, who had previously been prescribed an auto-injector were invited to participate. Semi-structured interviews explored the factors that positively or negatively impacted on carriage. Results Twenty teenagers with food or venom allergies were interviewed. Only two patients had used their auto-injector in the community, although several had been treated for severe reactions in hospital. Most teenagers made complex risk assessments to determine whether to carry the auto-injector. Most but not all decisions were rational and were at least partially informed by knowledge. Factors affecting carriage included location, who else would be present, the attitudes of others and physical features of the auto-injector. Teenagers made frequent risk assessments when deciding whether to carry their auto-injectors, and generally wanted to remain safe. Their decisions were complex, multi-faceted and highly individualised. Conclusions Rather than aiming for 100% carriage of auto-injectors, which remains an ambitious ideal, personalised education packages should aim to empower teenagers to make and act upon informed risk assessments. PMID:22409884
Mokarizadeh, Aram; Delirezh, Nowruz; Morshedi, Ahhmad; Mosayebi, Ghasem; Farshid, Amir-Abbas; Dalir-Naghadeh, Bahram
2012-01-01
Auto-reactive cells-mediated immune responses are responsible for the current tissue damages during autoimmunity. Accordingly, functional modulation of auto-reactive cells has been a pivotal aim in many of recent studies. In the current study, we investigated the possibility for insertion of regulatory molecules onto auto-reactive cells through exosomal nano-shuttles as a novel approach for phenotype modification of auto-reactive cells. The exosomes were isolated from supernatant of mesenchymal stem cells culture. Resultant exosomes co-cultured with lymphocytes were harvested from established EAE mice in the presence of antigenic MOG35-55 peptide. After 24 hr, insertion of exosomal tolerogenic molecules (PD-L1, TGF-β, galectin-1) onto auto-reactive cells were explored through flow cytometry. The potency of exosomal inserted membrane molecules to modulate phenotype of auto-reactive lymphocytes was assessed upon ELISA test for their-derived cytokines IFN-γ and IL-17. Incorporation of exosomal molecules into lymohocytes' membrane was confirmed by flow cytometric analyses for surface levels of mentioned molecules. Additionally, the decreased secretion of IFN-γ and IL-17 were detected in exosome pre-treated lymphocytes upon stimulation with MOG peptide. Mesenchymal stem cells -derived exosomes showed to be efficient organelles for insertion of bioactive tolerogenic molecules onto auto-reactive cells and modulation of their phenotypes.
Downtown Crossing: Auto Restricted Zone in Boston
DOT National Transportation Integrated Search
1982-07-01
The Downtown Crossing auto restricted zone, implemented in 1978, involved the : elimination of all auto traffic froma zone of twelve blocks encompassing six : different streets in Bostn's central business district. Some of the blocks were : pedestria...
NASA Astrophysics Data System (ADS)
Kim, Charlton C.; Wallace, Vincent P.; Rasouli, Alexandre; Coleno, Mariah L.; Dao, Xavier; Tromberg, Bruce J.; Wong, Brian J.
2000-05-01
Laser irradiation of hyaline cartilage result in stable shape changes due to temperature dependent stress relaxation. In this study, we determined the structural changes in chondrocytes within porcine nasal septal cartilage tissue over a 4-day period using a two-photon laser scanning microscope (TPM) following Nd:YAG laser irradiation (lambda equals 1.32 micrometer) using parameters that result in mechanical stress relaxation (6.0 W, 5.4 mm spot diameter). TPM excitation (780 nm) result in induction of fluorescence from endogenous agents such as NADH, NADPH, and flavoproteins in the 400 - 500 nm spectral region. During laser irradiation diffuse reflectance (from a probe HeNe laser, (lambda) equals 632.8 nm), surface temperature, and stress relaxation were measured dynamically. Each specimen received one, two, or three sequential laser exposures (average irradiation times of 5, 6, and 8 seconds). The cartilage reached a peak surface temperature of about 70 degrees Celsius during irradiation. Cartilage denatured in 50% EtOH (20 minutes) was used as a positive control. TPM was performed using a mode-locked 780 nm Titanium:Sapphire (Ti:Al203) beam with a, 63X, 1.2 N.A. water immersion objective (working distance of 200 mm) to detect the fluorescence emission from the chondrocytes. Images of chondrocytes were obtained at depths up to 150 microns (lateral resolution equals 35 micrometer X 35 micrometer). Images were obtained immediately following laser exposure, and also after 4 days in culture. In both cases, the irradiated and non-irradiated specimens do not show any discernible difference in general shape or auto fluorescence. In contrast, positive controls (immersed in 50% ethanol), show markedly increased fluorescence relative to both the native and irradiated specimens, in the cytoplasmic region.
Intrinsic Tau Acetylation Is Coupled to Auto-Proteolytic Tau Fragmentation
Cohen, Todd J.; Constance, Brian H.; Hwang, Andrew W.; James, Michael; Yuan, Chao-Xing
2016-01-01
Tau proteins are abnormally aggregated in a range of neurodegenerative tauopathies including Alzheimer’s disease (AD). Recently, tau has emerged as an extensively post-translationally modified protein, among which lysine acetylation is critical for normal tau function and its pathological aggregation. Here, we demonstrate that tau isoforms have different propensities to undergo lysine acetylation, with auto-acetylation occurring more prominently within the lysine-rich microtubule-binding repeats. Unexpectedly, we identified a unique intrinsic property of tau in which auto-acetylation induces proteolytic tau cleavage, thereby generating distinct N- and C-terminal tau fragments. Supporting a catalytic reaction-based mechanism, mapping and mutagenesis studies showed that tau cysteines, which are required for acetyl group transfer, are also essential for auto-proteolytic tau processing. Further mass spectrometry analysis identified the C-terminal 2nd and 4th microtubule binding repeats as potential sites of auto-cleavage. The identification of acetylation-mediated auto-proteolysis provides a new biochemical mechanism for tau self-regulation and warrants further investigation into whether auto-catalytic functions of tau are implicated in AD and other tauopathies. PMID:27383765
Intrinsic Tau Acetylation Is Coupled to Auto-Proteolytic Tau Fragmentation.
Cohen, Todd J; Constance, Brian H; Hwang, Andrew W; James, Michael; Yuan, Chao-Xing
2016-01-01
Tau proteins are abnormally aggregated in a range of neurodegenerative tauopathies including Alzheimer's disease (AD). Recently, tau has emerged as an extensively post-translationally modified protein, among which lysine acetylation is critical for normal tau function and its pathological aggregation. Here, we demonstrate that tau isoforms have different propensities to undergo lysine acetylation, with auto-acetylation occurring more prominently within the lysine-rich microtubule-binding repeats. Unexpectedly, we identified a unique intrinsic property of tau in which auto-acetylation induces proteolytic tau cleavage, thereby generating distinct N- and C-terminal tau fragments. Supporting a catalytic reaction-based mechanism, mapping and mutagenesis studies showed that tau cysteines, which are required for acetyl group transfer, are also essential for auto-proteolytic tau processing. Further mass spectrometry analysis identified the C-terminal 2nd and 4th microtubule binding repeats as potential sites of auto-cleavage. The identification of acetylation-mediated auto-proteolysis provides a new biochemical mechanism for tau self-regulation and warrants further investigation into whether auto-catalytic functions of tau are implicated in AD and other tauopathies.
Auto-fusion and the shaping of neurons and tubes
Soulavie, Fabien; Sundaram, Meera V.
2016-01-01
Cells adopt specific shapes that are necessary for specific functions. For example, some neurons extend elaborate arborized dendrites that can contact multiple targets. Epithelial and endothelial cells can form tiny seamless unicellular tubes with an intracellular lumen. Recent advances showed that cells can auto-fuse to acquire those specific shapes. During auto-fusion, a cell merges two parts of its own plasma membrane. In contrast to cell-cell fusion or macropinocytic fission, which result in the merging or formation of two separate membrane bound compartments, auto-fusion preserves one compartment, but changes its shape. The discovery of auto-fusion in C. elegans was enabled by identification of specific protein fusogens, EFF-1 and AFF-1, that mediate cell-cell fusion. Phenotypic characterization of eff-1 and aff-1 mutants revealed that fusogen-mediated fusion of two parts of the same cell can be used to sculpt dendritic arbors, reconnect two parts of an axon after injury, or form a hollow unicellular tube. Similar auto-fusion events recently were detected in vertebrate cells, suggesting that auto-fusion could be a widely used mechanism for shaping neurons and tubes. PMID:27436685
Technology to improve quality and accountability.
Kay, Jonathan
2006-01-01
A body of evidence has been accumulated to demonstrate that current practice is not sufficiently safe for several stages of central laboratory testing. In particular, while analytical and perianalytical steps that take place within the laboratory are subjected to quality control procedures, this is not the case for several pre- and post-analytical steps. The ubiquitous application of auto-identification technology seems to represent a valuable tool for reducing error rates. A series of projects in Oxford has attempted to improve processes which support several areas of laboratory medicine, including point-of-care testing, blood transfusion, delivery and interpretation of reports, and support of decision-making by clinicians. The key tools are auto-identification, Internet communication technology, process re-engineering, and knowledge management.
Wang, Xiaodan; Yamaguchi, Nobuyasu; Someya, Takashi; Nasu, Masao
2007-10-01
The micro-colony method was used to enumerate viable bacteria in composts. Cells were vacuum-filtered onto polycarbonate filters and incubated for 18 h on LB medium at 37 degrees C. Bacteria on the filters were stained with SYBR Green II, and enumerated using a newly developed micro-colony auto counting system which can automatically count micro-colonies on half the area of the filter within 90 s. A large number of bacteria in samples retained physiological activity and formed micro-colonies within 18 h, whereas most could not form large colonies on conventional media within 1 week. The results showed that this convenient technique can enumerate viable bacteria in compost rapidly for its efficient quality control.
NASA Technical Reports Server (NTRS)
Hepner, T. E.; Meyers, J. F. (Inventor)
1985-01-01
A laser velocimeter covariance processor which calculates the auto covariance and cross covariance functions for a turbulent flow field based on Poisson sampled measurements in time from a laser velocimeter is described. The device will process a block of data that is up to 4096 data points in length and return a 512 point covariance function with 48-bit resolution along with a 512 point histogram of the interarrival times which is used to normalize the covariance function. The device is designed to interface and be controlled by a minicomputer from which the data is received and the results returned. A typical 4096 point computation takes approximately 1.5 seconds to receive the data, compute the covariance function, and return the results to the computer.
Aboal, J R; Couto, J A; Fernández, J A; Carballeira, A
2008-06-01
Transplants of the moss Pseudoscleropodium purum were placed under shade, and with an auto irrigation system, at five sites in the surroundings of an aluminium smelter to enable study of the possible effects of F on different physiological parameters after exposure periods of 28 and 56 days. Reference thresholds for the content of Chl a+b and for the pigment indexes of Chl a/b and D665/D665a were established with the data corresponding to 22 transplants of each duration of exposure, at seven sites where there was little or no contamination by F. The highest determination coefficients for the levels of F in moss were those obtained for chlorophyll content (Chl a+b) and the D665/D665a pigment index, with the effects being most evident in the transplants exposed to the contamination for 56 days.
NASA Astrophysics Data System (ADS)
Luque-Espinar, J. A.; Pardo-Igúzquiza, E.; Grima-Olmedo, J.; Grima-Olmedo, C.
2018-06-01
During the last years there has been an increasing interest in assessing health risks caused by exposure to contaminants found in soil, air, and water, like heavy metals or emerging contaminants. This work presents a study on the spatial patterns and interaction effects among relevant heavy metals (Sb, As and Pb) that may occur together in different minerals. Total organic carbon (TOC) have been analyzed too because it is an essential component in the regulatory mechanisms that control the amount of metal in soils. Even more, exposure to these elements is associated with a number of diseases and environmental problems. These metals can have both natural and anthropogenic origins. A key component of any exposure study is a reliable model of the spatial distribution the elements studied. A geostatistical analysis have been performed in order to show that selected metals are auto-correlated and cross-correlated and type and magnitude of such cross-correlation varies depending on the spatial scale under consideration. After identifying general trends, we analyzed the residues left after subtracting the trend from the raw variables. Three scales of variability were identified (compounds or factors) with scales of 5, 35 and 135 km. The first factor (F1) basically identifies anomalies of natural origin but, in some places, of anthropogenics origin as well. The other two are related to geology (F2 and F3) although F3 represents more clearly geochemical background related to large lithological groups. Likewise, mapping of two major structures indicates that significant faults have influence on the distribution of the studied elements. Finally, influence of soil and lithology on groundwater by means of contingency analysis was assessed.
The Implementation of Downtown Auto-Restricted Projects
DOT National Transportation Integrated Search
1984-06-01
In 1975 UMTA's Office of Service and Methods Demonstration launched a demonstration program of Auto Restricted Zones (ARZs) which went beyond the traditional scope of linear pedestrian malls. ARZs involve auto restriction in a large geographic area w...
NASA Astrophysics Data System (ADS)
Saijyo, Katsuya; Nishiwaki, Kazuie; Yoshihara, Yoshinobu
The CFD simulations were performed integrating the low-temperature oxidation reaction. Analyses were made with respect to the first auto-ignition location in the case of a premixed-charge compression auto-ignition in a laminar flow field and in the case of the auto-ignition in an end gas during an S. I. Engine combustion process. In the latter simulation, the spatially-filtered transport equations were solved to express fluctuating temperatures in a turbulent flow in consideration of strong non-linearity to temperature in the reaction equations. It is suggested that the first auto-ignition location does not always occur at higher-temperature locations and that the difference in the locations of the first auto-ignition depends on the time period during which the local end gas temperature passes through the region of shorter ignition delay, including the NTC region.
Sajedi, Vahid; Movahedi, Masoud; Aghamohammadi, Asghar; Aghamohamadi, Asghar; Gharagozlou, Mohammad; Ghareguzlou, Mohammad; Shafiei, Alireza; Soheili, Habib; Sanajian, Nahal
2011-06-01
Intradermal injection of autologous serum and plasma elicit a cutaneous reactivity in almost 45-60% of patients with Chronic Idiopathic Urticaria (CIU). This reactivity is associated with the presence of auto antibodies against IgE or IgE receptors. This study was carried out to compare the cutaneous reactivity of autologous serum and plasma skin tests in a series of patients with CIU for diagnosis of auto antibodies against IgE or IgE receptor. Fifty eight patients with CIU were injected intradermally with autologous serum and plasma (anticoagulated by citrate). Histamine was used as positive control and normal saline as negative control. The study group was checked by routine laboratory tests (CBC, U/A etc), allergens with skin prick tests, and serum IgE level, and auto antibodies against thyroid as well. Duration of urticaria was another factor which was assessed.There was no significant difference between positive ASST and positive APST patients for the above mentioned tests. 77.6% of the patients were Positive for APST and 65.5% were ASST positive. Duration of urticaria was longer in patients with positive ASST and APST than ASST and APST negative patients, although the difference was not statistically significant.Autologus serum skin test (ASST) and autologous plasma skin test (APST) could be used for estimation of duration and severity of urticaria and planning for the treatment.
Muñoz-Organero, Mario; Davies, Richard; Mawson, Sue
2017-01-01
Insole pressure sensors capture the force distribution patterns during the stance phase while walking. By comparing patterns obtained from healthy individuals to patients suffering different medical conditions based on a given similarity measure, automatic impairment indexes can be computed in order to help in applications such as rehabilitation. This paper uses the data sensed from insole pressure sensors for a group of healthy controls to train an auto-encoder using patterns of stochastic distances in series of consecutive steps while walking at normal speeds. Two experiment groups are compared to the healthy control group: a group of patients suffering knee pain and a group of post-stroke survivors. The Mahalanobis distance is computed for every single step by each participant compared to the entire dataset sensed from healthy controls. The computed distances for consecutive steps are fed into the previously trained autoencoder and the average error is used to assess how close the walking segment is to the autogenerated model from healthy controls. The results show that automatic distortion indexes can be used to assess each participant as compared to normal patterns computed from healthy controls. The stochastic distances observed for the group of stroke survivors are bigger than those for the people with knee pain.
NASA Technical Reports Server (NTRS)
Gladden, Roy E.; Khanampornpan, Teerapat; Fisher, Forest W.
2010-01-01
Version 5.0 of the AutoGen software has been released. Previous versions, variously denoted Autogen and autogen, were reported in two articles: Automated Sequence Generation Process and Software (NPO-30746), Software Tech Briefs (Special Supplement to NASA Tech Briefs), September 2007, page 30, and Autogen Version 2.0 (NPO- 41501), NASA Tech Briefs, Vol. 31, No. 10 (October 2007), page 58. To recapitulate: AutoGen (now signifying automatic sequence generation ) automates the generation of sequences of commands in a standard format for uplink to spacecraft. AutoGen requires fewer workers than are needed for older manual sequence-generation processes, and greatly reduces sequence-generation times. The sequences are embodied in spacecraft activity sequence files (SASFs). AutoGen automates generation of SASFs by use of another previously reported program called APGEN. AutoGen encodes knowledge of different mission phases and of how the resultant commands must differ among the phases. AutoGen also provides means for customizing sequences through use of configuration files. The approach followed in developing AutoGen has involved encoding the behaviors of a system into a model and encoding algorithms for context-sensitive customizations of the modeled behaviors. This version of AutoGen addressed the MRO (Mars Reconnaissance Orbiter) primary science phase (PSP) mission phase. On previous Mars missions this phase has more commonly been referred to as mapping phase. This version addressed the unique aspects of sequencing orbital operations and specifically the mission specific adaptation of orbital operations for MRO. This version also includes capabilities for MRO s role in Mars relay support for UHF relay communications with the MER rovers and the Phoenix lander.
Sowa, Mandy; Hiemann, Rico; Schierack, Peter; Reinhold, Dirk; Conrad, Karsten; Roggenbuck, Dirk
2017-08-01
Occurrence of autoantibodies (autoAbs) is a hallmark of autoimmune diseases, and the analysis thereof is an essential part in the diagnosis of organ-specific autoimmune and systemic autoimmune rheumatic diseases (SARD), especially connective tissue diseases (CTDs). Due to the appearance of autoAb profiles in SARD patients and the complexity of the corresponding serological diagnosis, different diagnostic strategies have been suggested for appropriate autoAb testing. Thus, evolving assay techniques and the continuous discovery of novel autoantigens have greatly influenced the development of these strategies. Antinuclear antibody (ANA) analysis by indirect immunofluorescence (IIF) on tissue and later cellular substrates was one of the first tests introduced into clinical routine and is still an indispensable tool for CTD serology. Thus, screening for ANA by IIF is recommended to be followed by confirmatory testing of positive findings employing different assay techniques. Given the continuous growth in the demand for autoAb testing, IIF has been challenged as the standard method for ANA and other autoAb analyses due to lacking automation, standardization, modern data management, and human bias in IIF pattern interpretation. To address these limitations of autoAb testing, the CytoBead® technique has been introduced recently which enables automated interpretation of cell-based IIF and quantitative autoAb multiplexing by addressable microbead immunoassays in one reaction environment. Thus, autoAb screening and confirmatory testing can be combined for the first time. The present review discusses the history of autoAb assay techniques in this context and gives an overview and outlook of the recent progress in emerging technologies.
Fitoussi, Olivier; Belhadj, Karim; Mounier, Nicolas; Parrens, Marie; Tilly, Hervé; Salles, Gilles; Feugier, Pierre; Ferme, Christophe; Ysebaert, Loic; Gabarre, Jean; Herbrecht, Raoul; Janvier, Maud; Van Den Neste, Eric; Morschhauser, Franck; Casasnovas, Olivier; Ghesquieres, Hervé; Anglaret, Bruno; Brechignac, Sabine; Haioun, Corinne; Gisselbrecht, Christian
2011-01-01
Background As rituximab combined with CHOP improves complete remission and overall survival in diffuse large B-cell lymphoma, intensified chemotherapy followed by autologous stem-cell transplantation has also been advocated for high-risk patients. The aim of this study was to establish whether or not combining rituximab with high-dose chemotherapy and auto-transplantation also benefits patient survival. Design and Methods The LNH2003-3 study was a phase II trial including diffuse large B-cell lymphoma patients with 2 or 3 International Prognostic Index factors. They received four cycles of intensive biweekly chemotherapy with rituximab, doxorubicine, cyclophosphamide, vindesine, bleomycine, prednisolone (R-ACVBP) followed by auto-transplantation in responding patients. Two hundred and nine patients under 60 years of age were included in the study and 155 responding patients underwent auto-transplantation. In addition, a case-control study was performed by matching (1:1) 181 patients treated with R-ACVBP with ACVBP patients not given rituximab but submitted to auto-transplantation from the previous LNH1998-3 trial. Results With a median follow up of 45 months, 4-year progression-free survival and overall survival were estimated at 76% (CI: 69–81) and 78% (CI: 72–83), respectively. There was no difference between patients with 2 or 3 International Prognostic Index factors. Four year progression-free survival was significantly higher in R-ACVBP than ACVBP patients (74% vs. 58%; P=0.0005). There was also a significant increase in 4-year overall survival (76% vs. 68%; P=0.0494). Conclusions In high-risk diffuse large B-cell lymphoma patients, treatment with R-ACVBP followed by auto-transplantation results in a 78% 4-year overall survival which should be compared to other approaches. (Clinicaltrials.gov identifier: NCT00144807) PMID:21546499
Code of Federal Regulations, 2012 CFR
2012-10-01
... Group Auto Club Enterprise Insurance Group Auto-Owners Insurance Group Berkshire Hathaway/GEICO... Insurance Companies Metropolitan Life Auto & Home Group Mercury General Group Nationwide Group Progressive...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Group Auto Club Enterprise Insurance Group Auto-Owners Insurance Group Berkshire Hathaway/GEICO... Insurance Companies Metropolitan Life Auto & Home Group Mercury General Group Nationwide Group Progressive...
Desai, Himanshu; Patel, Anil; Patel, Pinal; Grant, Brydon J B; Mador, M Jeffery
2009-11-01
Autotitrating continuous positive airway pressure (auto-CPAP) devices now have a smart card (a pocket-sized card with embedded integrated circuits which records data from the CPAP machine such as CPAP usage, CPAP pressure, large leak, etc.) which can estimate the Apnea-Hypopnea Index (AHI) on therapy. The aim of this study was to determine the accuracy of auto-CPAP in estimating the residual AHI in patients with obstructive sleep apnea (OSA) who were treated with auto-CPAP without a CPAP titration study. We studied 99 patients with OSA from April 2005 to May 2007 who underwent a repeat sleep study using auto-CPAP. The estimated AHI from auto-CPAP was compared with the AHI from an overnight polysomnogram (PSG) on auto-CPAP using Bland-Altman plot and likelihood ratio analyses. A PSG AHI cutoff of five events per hour was used to differentiate patients optimally treated with auto-CPAP from those with residual OSA on therapy. Bland and Altman analysis showed good agreement between auto-CPAP AHI and PSG AHI. There was no significant bias when smart card estimates of AHI at home were compared to smart card estimates obtained in the sleep laboratory. An auto-CPAP cutoff for the AHI of six events per hour was shown to be optimal for differentiating patients with and without residual OSA with a sensitivity of 0.92 (95% confidence interval (CI) 0.76 to 0.98) and specificity of 0.90 (95% CI 0.82 to 0.95) with a positive likelihood ratio (LR) of 9.6 (95% CI 5.1 to 21.5) and a negative likelihood ratio of 0.085 (95% CI 0.02 to 0.25). Auto-CPAP AHI of eight events per hour yielded the optimal sensitivity (0.94, 95% CI 0.73 to 0.99) and specificity (0.90, 95% CI 0.82 to 0.95) with a positive LR of 9.6 (95% CI 5.23 to 20.31) and a negative LR of 0.065 (95% CI 0.004 to 0.279) to identify patients with a PSG AHI of > or = 10 events per hour. Auto-CPAP estimate of AHI may be used to estimate residual AHI in patients with OSA of varying severity treated with auto-CPAP.
Autonomous Formation Flying from Ground to Flight
NASA Technical Reports Server (NTRS)
Chapman, Keith B.; Dell, Gregory T.; Rosenberg, Duane L.; Bristow, John
1999-01-01
The cost of on-orbit operations remains a significant and increasingly visible concern in the support of satellite missions. Headway has been made in automating some ground operations; however, increased mission complexity and more precise orbital constraints have compelled continuing human involvement in mission design and maneuver planning operations. AI Solutions, Inc. in cooperation with the National Aeronautics and Space Administration's (NASA) Goddard Space Flight Center (GSFC) has tackled these more complex problems through the development of AutoCon as a tool for an automated solution. NASA is using AutoCon to automate the maneuver planning for the Earth Orbiter-1 (EO-1) mission. AutoCon was developed originally as a ground system tool. The EO-1 mission will be using a scaled version of AutoCon on-board the EO-1 satellite to command orbit adjustment maneuvers. The flight version of AutoCon plans maneuvers based on formation flying algorithms developed by GSFC, JPL, and other industry partners. In its fully autonomous mode, an AutoCon planned maneuver will be executed on-board the satellite without intervention from the ground. This paper describes how AutoCon automates maneuver planning for the formation flying constraints of the EO-1 mission. AutoCon was modified in a number of ways to automate the maneuver planning on-board the satellite. This paper describes how the interface and functionality of AutoCon were modified to support the on-board system. A significant component of this modification was the implementation of a data smoother, based on a Kalman filter, that ensures that the spacecraft states estimated by an on-board GPS receiver are as accurate as possible for maneuver planning. This paper also presents the methodology use to scale the AutoCon functionality to fit and execute on the flight hardware. This paper also presents the modes built that allow the incremental phasing in of autonomy. New technologies for autonomous operations are usually received with significant, and probably appropriate trepidation. A number of safeguards have been designed in both AutoCon and the interfacing systems to alleviate the potential of mission-impacting anomalies from the on-board autonomous system. This paper describes the error checking, input data integrity validation and limits set on maneuvers in AutoCon and the on-board system.
Autonomous Formation Flying from the Ground to Flight
NASA Technical Reports Server (NTRS)
Chapman, Keith B.; Dell, Gregory T.; Rosenberg, Duane L.; Bristow, John
1999-01-01
The cost of on-orbit operations remains a significant and increasingly visible concern in the support of satellite missions. Headway has been made in automating some ground operations; however, increased mission complexity and more precise orbital constraints have compelled continuing human involvement in mission design and maneuver planning operations. AI Solutions, Inc. in cooperation with the National Aeronautics and Space Administration's (NASA) Goddard Space Flight Center (GSFC) has tackled these more complex problems through the development of AutoCon(TM) as a tool for an automated solution. NASA is using AutoCon(TM) to automate the maneuver planning for the Earth Orbiter-1 (EO-1) mission. AutoCon(TM) was developed originally as a ground system tool. The EO-1 mission will be using a scaled version of AutoCon(TM) on-board the EO-1 satellite to command orbit adjustment maneuvers. The flight version of AutoCon(TM) plans maneuvers based on formation flying algorithms developed by GSFC, JPL, and other industry partners. In its fully autonomous mode, an AutoCon(TM) planned maneuver will be executed on-board the satellite without intervention from the ground. This paper describes how AutoCon(TM) automates maneuver planning for the formation flying constraints of the EO-1 mission. AutoCon(TM) was modified in a number of ways to automate the maneuver planning on-board the satellite. This paper describes how the interface and functionality of AutoCon(TM) were modified to support the on-board system. A significant component of this modification was the implementation of a data smoother, based on a Kalman filter, that ensures that the spacecraft states estimated by an on-board GPS receiver are as accurate as possible for maneuver planning. This paper also presents the methodology used to scale the AutoCon(TM) functionality to fit and execute on the flight hardware. This paper also presents the modes built into the system that allow the incremental phasing in of autonomy. New technologies for autonomous operations are usually received with significant, and probably appropriate, trepidation. A number of safeguards have been designed in both AutoCon(TM) and the interfacing systems to alleviate the potential of mission-impacting anomalies from the on-board autonomous system. This paper describes the error checking, input data integrity validation, and limits set on maneuvers in AutoCon(TM) and the on-board system.
ERIC Educational Resources Information Center
Fuqua, Lou; Fuqua, Debbie
Designed to address the skills that an auto parts specialist must master in order to be effective in the market place, this manual consists of 13 units of instruction. Covered in the units are orientation; human relations; communications; safety; parts and systems identification; stocking, shipping, and receiving; inventory control; cataloging and…
Development, Integration and Testing of Automated Triggering Circuit for Hybrid DC Circuit Breaker
NASA Astrophysics Data System (ADS)
Kanabar, Deven; Roy, Swati; Dodiya, Chiragkumar; Pradhan, Subrata
2017-04-01
A novel concept of Hybrid DC circuit breaker having combination of mechanical switch and static switch provides arc-less current commutation into the dump resistor during quench in superconducting magnet operation. The triggering of mechanical and static switches in Hybrid DC breaker can be automatized which can effectively reduce the overall current commutation time of hybrid DC circuit breaker and make the operation independent of opening time of mechanical switch. With this view, a dedicated control circuit (auto-triggering circuit) has been developed which can decide the timing and pulse duration for mechanical switch as well as static switch from the operating parameters. This circuit has been tested with dummy parameters and thereafter integrated with the actual test set up of hybrid DC circuit breaker. This paper deals with the conceptual design of the auto-triggering circuit, its control logic and operation. The test results of Hybrid DC circuit breaker using this circuit have also been discussed.
NASA Astrophysics Data System (ADS)
Sawicki, Jean-Paul; Saint-Eve, Frédéric; Petit, Pierre; Aillerie, Michel
2017-02-01
This paper presents results of experiments aimed to verify a formula able to compute duty cycle in the case of pulse width modulation control for a DC-DC converter designed and realized in laboratory. This converter, called Magnetically Coupled Boost (MCB) is sized to step up only one photovoltaic module voltage to supply directly grid inverters. Duty cycle formula will be checked in a first time by identifying internal parameter, auto-transformer ratio, and in a second time by checking stability of operating point on the side of photovoltaic module. Thinking on nature of generator source and load connected to converter leads to imagine additional experiments to decide if auto-transformer ratio parameter could be used with fixed value or on the contrary with adaptive value. Effects of load variations on converter behavior or impact of possible shading on photovoltaic module are also mentioned, with aim to design robust control laws, in the case of parallel association, designed to compensate unwanted effects due to output voltage coupling.
Gimenez-Pinto, Vianney; Ye, Fangfu; Mbanga, Badel; Selinger, Jonathan V.; Selinger, Robin L. B.
2017-01-01
Various experimental and theoretical studies demonstrate that complex stimulus-responsive out-of-plane distortions such as twist of different chirality, emergence of cones, simple and anticlastic bending can be engineered and pre-programmed in a liquid crystalline rubbery material given a well-controlled director microstructure. Via 3-d finite element simulation studies, we demonstrate director-encoded chiral shape actuation in thin-film nematic polymer networks under external stimulus. Furthermore, we design two complex director fields with twisted nematic domains and nematic disclinations that encode a pattern of folds for an auto-origami box. This actuator will be flat at a reference nematic state and form four well-controlled bend distortions as orientational order changes. Device fabrication is applicable via current experimental techniques. These results are in qualitative agreement with theoretical predictions, provide insight into experimental observations, and demonstrate the value of finite element methods at the continuum level for designing and engineering liquid crystal polymeric devices. PMID:28349949
The Pathogenesis of Autoimmune Liver Disease.
Arndtz, Katherine; Hirschfield, Gideon M
Autoimmune liver disease (AILD) encompasses 3 main distinct clinical diseases: autoimmune hepatitis, primary biliary cholangitis (formally known as cirrhosis, PBC) and primary sclerosing cholangitis (PSC). These conditions are an important, yet under-appreciated cause of patient morbidity and mortality with ongoing unmet needs for further research and clinical advances. There is observational evidence for genetic predisposition, with all 3 conditions being more common in first degree relatives. AILD is associated with the presence of auto-antibodies and higher risks of other non-hepatic auto-immune conditions. Genetic risk association studies have identified HLA and non-HLA risk loci for the development of disease, with some HLA loci providing prognostic information. This re-enforces the concept that genetic predisposition to autoimmunity is important, likely in the context of environmental exposures. Such environmental triggers are unclear but relevant risks include smoking, drug and xenobiotic exposure as well as the complexities of the microbiome. There is evidence for a loss of immune tolerance to self-antigens playing a part in the development of these conditions. In particular the IL-2 and IL-12 regulatory pathways have been implicated in pre-disposing to an unopposed inflammatory response within the liver. Main immunological themes revolve around loss of immune tolerance leading to T-cell mediated injury, imbalance in the regulation of immune cells and defective immune response to foreign antigens. For PBC and PSC, there is then the added complexity of the consequences of cholestasis on hepato-biliary injury, immune regulation and liver fibrosis. Whilst specific disease causes and triggers are still lacking, AILD arises on the background of collective genetic and environmental risk, leading to chronic and abnormal hepato-biliary immune responses. Effective and more rational therapy will ultimately be developed when the multiple pathways to liver injury are better understood. © 2016 S. Karger AG, Basel.
[DNA Extraction from Old Bones by AutoMate Express™ System].
Li, B; Lü, Z
2017-08-01
To establish a method for extracting DNA from old bones by AutoMate Express™ system. Bones were grinded into powder by freeze-mill. After extraction by AutoMate Express™, DNA were amplified and genotyped by Identifiler®Plus and MinFiler™ kits. DNA were extracted from 10 old bone samples, which kept in different environments with the postmortem interval from 10 to 20 years, in 3 hours by AutoMate Express™ system. Complete STR typing results were obtained from 8 samples. AutoMate Express™ system can quickly and efficiently extract DNA from old bones, which can be applied in forensic practice. Copyright© by the Editorial Department of Journal of Forensic Medicine
Doppler, Kathrin; Appeltshauser, Luise; Krämer, Heidrun H; Ng, Judy King Man; Meinl, Edgar; Villmann, Carmen; Brophy, Peter; Dib-Hajj, Sulayman D; Waxman, Stephen G; Weishaupt, Andreas; Sommer, Claudia
2015-01-01
Multifocal motor neuropathy is an immune mediated disease presenting with multifocal muscle weakness and conduction block. IgM auto-antibodies against the ganglioside GM1 are detectable in about 50% of the patients. Auto-antibodies against the paranodal proteins contactin-1 and neurofascin-155 and the nodal protein neurofascin-186 have been detected in subgroups of patients with chronic inflammatory demyelinating polyneuropathy. Recently, auto-antibodies against neurofascin-186 and gliomedin were described in more than 60% of patients with multifocal motor neuropathy. In the current study, we aimed to validate this finding, using a combination of different assays for auto-antibody detection. In addition we intended to detect further auto-antibodies against paranodal proteins, specifically contactin-1 and neurofascin-155 in multifocal motor neuropathy patients' sera. We analyzed sera of 33 patients with well-characterized multifocal motor neuropathy for IgM or IgG anti-contactin-1, anti-neurofascin-155 or -186 antibodies using enzyme-linked immunosorbent assay, binding assays with transfected human embryonic kidney 293 cells and murine teased fibers. We did not detect any IgM or IgG auto-antibodies against contactin-1, neurofascin-155 or -186 in any of our multifocal motor neuropathy patients. We conclude that auto-antibodies against contactin-1, neurofascin-155 and -186 do not play a relevant role in the pathogenesis in this cohort with multifocal motor neuropathy.
Wang, Wei; Lim, Liangzhong; Baskaran, Yohendran; Manser, Ed; Song, Jianxing
2013-08-16
Six human PAK members are classified into groups I (PAKs 1-3) and II (PAK4-6). Previously, only group I PAKs were thought to be auto-inhibited but very recently PAK4, the prototype of group II PAKs, has also been shown to be auto-inhibited by its N-terminal regulatory domain. However, the complete auto-inhibitory domain (AID) sequence remains undefined and the mechanism underlying its auto-inhibition is largely elusive. Here, the N-terminal regulatory domain of PAK4 sufficient for auto-inhibiting and binding Cdc42/Rac was characterized to be intrinsically unstructured, but nevertheless we identified the entire AID sequence by NMR. Strikingly, an AID peptide was derived by deleting the binding-unnecessary residues, which has a Kd of 320 nM to the PAK4 catalytic domain. Consequently, the PAK4 crystal structure complexed with the entire AID has been determined, which reveals that the complete kinase cleft is occupied by 20 AID residuescomposed of an N-terminal α-helix and a previously-identified pseudosubstrate motif, thus achieving auto-inhibition. Our study reveals that PAK4 is auto-inhibited by a novel mechanism which is completely different from that for PAK1, thus bearing critical implications for design of inhibitors specific for group II PAKs. Copyright © 2013 Elsevier Inc. All rights reserved.
Adak, Prasenjit; Sahu, Ravi; Elumalai, Suresh Pandian
2016-02-15
Vehicular emission is one of the most important contributors of urban air pollution. To quantify the impact of traffic on urban air quality, it is necessary to quantify vehicular emission. In many cities of India, such as Dhanbad, shared auto-rickshaw is the pre-dominant mode of transportation. Indian Driving Cycle (IDC) and Modified Indian Driving Cycle (MIDC) are used for emission testing of motorcycles, shared auto-rickshaws and passenger cars in India for regulatory purposes. IDC used for motorcycles and shared auto-rickshaws does not recognize the difference in two vehicle classes in terms of driving pattern. In real world, shared auto-rickshaws, behave differently than motorcycles. To quantify the impact of shared auto-rickshaws on urban air quality accurately, emission factors (EFs) are required to derive from real-world driving cycles (DCs). In heterogeneous traffic, vehicles of one class affect the behavior of vehicles of other classes. To estimate the emissions from different vehicle classes accurately, EFs for motorcycles and passenger cars are also required to be revised. In this study, real-world DCs were developed for motorcycles, shared auto-rickshaws and passenger cars in Dhanbad. Developed DCs were used to calculate EFs for respective classes. Shared auto-rickshaws were found to have the highest deviation from EFs derived using IDC. Copyright © 2015 Elsevier B.V. All rights reserved.
SU-F-J-156: The Feasibility of MR-Only IMRT Planning for Prostate Anatomy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vaitheeswaran, R; Sivaramakrishnan, KR; Kumar, Prashant
Purpose: For prostate anatomy, previous investigations have shown that simulated CT (sCT) generated from MR images can be used for accurate dose computation. In this study, we demonstrate the feasibility of MR-only IMRT planning for prostate case. Methods: Regular CT (rCT) and MR images of the same patient were acquired for prostate anatomy. Regions-of-interest (ROIs) i.e. target and risk structures are delineated on the rCT. A simulated CT (sCT) is generated from the MR image using the method described by Schadewaldt N et al. Their work establishes the clinical acceptability of dose calculation results on the sCT when compared tomore » rCT. rCT and sCT are rigidly registered to ensure proper alignment between the two images. rCT and sCT are overlaid on each other and slice-wise visual inspection confirms excellent agreement between the two images. ROIs on the rCT are copied over to sCT. Philips AutoPlanning solution is used for generating treatment plans. The same treatment technique protocol (plan parameters and clinical goals) is used to generate AutoPlan-rCT and AutoPlan-sCT respectively for rCT and and sCT. DVH comparison on ROIs and slice-wise evaluation of dose is performed between AutoPlan-rCT and AutoPlan-sCT. Delivery parameters i.e. beam and corresponding segments from the AutoPlan-sCT are copied over to rCT and dose is computed to get AutoPlan-sCT-on-rCT. Results: Plan evaluation is done based on Dose Volume Histogram (DVH) of ROIs and manual slice-wise inspection of dose distribution. Both AutoPlan-rCT and AutoPlan-sCT provide a clinically acceptable plan. Also, AutoPlan-sCT-on-rCT shows excellent agreement with AutoPlan-sCT. Conclusion: The study demonstrates that it is feasible to do IMRT planning on the simulated CT image obtained from MR image for prostate anatomy. The research is supported by Philips India Ltd.« less
B-1 Systems Approach to Training. Task Analysis Listings
1975-07-01
OFF FUEL VALVES AND PUMPS PHR-OFF FUEL VALVES AND PUMPS = AUTO ^FT TFR MODE LAND SELECTOR SWITCHES TQ *QFF...TFR MODE SWITCH-RIGHT «JFT L TFR MODE SELECT SWITCH TQ * TF1 CHECKLIST TFR MODE SWITCH-LEFT TFR MODE SWITCH-LEFT...DOOR HANDLE ENTRY LADDER CONTROL SWITCH ENTRY LADDER CONTROL SWITCH = DN* 16.1.1.001.OC* SET TANK FILL VALVE SWS ON
Crewstation Assessment of Reach as Applied to the OH-58A Helicopter
1984-12-13
CLUSTER ENO ENO OFICE FIELD 0gMA BR? OMR BRI T CONSOLE LTS NST LTSI OFF OFF NO BRT MVO ANTI COLLISION FOS LTS Lii LTS OFF *OFF CFF OFF OFr AUTO Hyp...gINTER)-- 2 ANALISIS OPION(1-ALL OPERATORq,2-OPZRATORS ON LOS ONLY)--L 1 RFACH ALCORITHNl(lPASS THROUGH CONTROL,2-TERNINAIE &T CONTROL)-- 2 ***OPERATOR NO
Chuang, Ho-Chiao; Hsu, Hsiao-Yu; Nieh, Shu-Kan; Tien, Der-Chi
2015-01-01
The purpose of this study is to assess the feasibility of using the analytical technique of ultrasound images in combination with an auto tumor localization system. During respiration, the activity of breathing in and out causes organs displacement at the lower lobe of the lung, and the maximum displacement range happens in the Superior-Inferior (SI) direction. Therefore, in this study all the tumor positioning is in SI direction under respiratory compensation, in which the compensations are carried out to the organs at the lower lobe and adjacent to the lower lobe of lung.In this research, due to the processes of ultrasound imaging generation, image analysis and signal transmission, when the captured respiratory signals are sent to auto tumor localization system, there was a signal time delay. The total delay time of the entire signal transmission process was 0.254 ± 0.023 seconds (with the lowest standard deviation) after implementing a series of analyses. To compensate for this signal delay time (0.254 ± 0.023 sec), a phase lead compensator (PLC) was designed and built into the auto tumor localization system. By analyzing the impact of the delay time and the respiratory waveforms under different frequencies on the phase lead compensator, an overall system delay time can be configured. Results showed as the respiratory frequency increased, variable value ``a'' and the subsequent gain ``k'' in the controller becomes larger. Moreover, value ``a'' and ``k'' increased as the system delay time increased when the respiratory frequency was fixed. The relationship of value ``a'' and ``k'' to the respiratory frequency can be obtained by using the curve fitting method to compensate for the respiratory motion for tumor localization. Through the comparison of the uncompensated signal and the compensated signal performed by the auto tumor localization system on the simulated respiratory signal, the feasibility of using ultrasound image analysis technology combined with the developed auto tumor localization system can be evaluated. The results show that the simulated respiratory signals under different frequencies of 0.5, 0.333, 0.25, 0.2 and 0.167 Hz with phase lead compensators were improved and stabilized. The compensation rate increased to the range of 7.04$∼ $18.82%, and the final compensation rate is about 97%. Therefore the auto tumor localization system combined with the ultrasound image analysis techniques is feasible.In this study, the developed ultrasound image analysis techniques combined into the auto tumor localization system has the following four advantages: (1) It is a non-invasive way (ultrasonic images) to monitor the entire compensating process of the active respiration instead of using a C-arm (invasive) to observe the organs motion. (2) During radiation therapy, the whole treatment process can be continuous, which can save the overall treatment time. (3) It is an independent system, which can be mounted onto any treatment couch. (4) Users can operate this system easily without the need of prior complicated training process.
Cha, Dong Ik; Lee, Min Woo; Kim, Ah Yeong; Kang, Tae Wook; Oh, Young-Taek; Jeong, Ja-Yeon; Chang, Jung-Woo; Ryu, Jiwon; Lee, Kyong Joon; Kim, Jaeil; Bang, Won-Chul; Shin, Dong Kuk; Choi, Sung Jin; Koh, Dalkwon; Seo, Bong Koo; Kim, Kyunga
2017-11-01
Background A major drawback of conventional manual image fusion is that the process may be complex, especially for less-experienced operators. Recently, two automatic image fusion techniques called Positioning and Sweeping auto-registration have been developed. Purpose To compare the accuracy and required time for image fusion of real-time ultrasonography (US) and computed tomography (CT) images between Positioning and Sweeping auto-registration. Material and Methods Eighteen consecutive patients referred for planning US for radiofrequency ablation or biopsy for focal hepatic lesions were enrolled. Image fusion using both auto-registration methods was performed for each patient. Registration error, time required for image fusion, and number of point locks used were compared using the Wilcoxon signed rank test. Results Image fusion was successful in all patients. Positioning auto-registration was significantly faster than Sweeping auto-registration for both initial (median, 11 s [range, 3-16 s] vs. 32 s [range, 21-38 s]; P < 0.001] and complete (median, 34.0 s [range, 26-66 s] vs. 47.5 s [range, 32-90]; P = 0.001] image fusion. Registration error of Positioning auto-registration was significantly higher for initial image fusion (median, 38.8 mm [range, 16.0-84.6 mm] vs. 18.2 mm [6.7-73.4 mm]; P = 0.029), but not for complete image fusion (median, 4.75 mm [range, 1.7-9.9 mm] vs. 5.8 mm [range, 2.0-13.0 mm]; P = 0.338]. Number of point locks required to refine the initially fused images was significantly higher with Positioning auto-registration (median, 2 [range, 2-3] vs. 1 [range, 1-2]; P = 0.012]. Conclusion Positioning auto-registration offers faster image fusion between real-time US and pre-procedural CT images than Sweeping auto-registration. The final registration error is similar between the two methods.
Botros, Andrew; van Dijk, Bas; Killian, Matthijs
2007-05-01
AutoNRT is an automated system that measures electrically evoked compound action potential (ECAP) thresholds from the auditory nerve with the Nucleus Freedom cochlear implant. ECAP thresholds along the electrode array are useful in objectively fitting cochlear implant systems for individual use. This paper provides the first detailed description of the AutoNRT algorithm and its expert systems, and reports the clinical success of AutoNRT to date. AutoNRT determines thresholds by visual detection, using two decision tree expert systems that automatically recognise ECAPs. The expert systems are guided by a dataset of 5393 neural response measurements. The algorithm approaches threshold from lower stimulus levels, ensuring recipient safety during postoperative measurements. Intraoperative measurements use the same algorithm but proceed faster by beginning at stimulus levels much closer to threshold. When searching for ECAPs, AutoNRT uses a highly specific expert system (specificity of 99% during training, 96% during testing; sensitivity of 91% during training, 89% during testing). Once ECAPs are established, AutoNRT uses an unbiased expert system to determine an accurate threshold. Throughout the execution of the algorithm, recording parameters (such as implant amplifier gain) are automatically optimised when needed. In a study that included 29 intraoperative and 29 postoperative subjects (a total of 418 electrodes), AutoNRT determined a threshold in 93% of cases where a human expert also determined a threshold. When compared to the median threshold of multiple human observers on 77 randomly selected electrodes, AutoNRT performed as accurately as the 'average' clinician. AutoNRT has demonstrated a high success rate and a level of performance that is comparable with human experts. It has been used in many clinics worldwide throughout the clinical trial and commercial launch of Nucleus Custom Sound Suite, significantly streamlining the clinical procedures associated with cochlear implant use.
Family factors associated with auto-aggressiveness in adolescents in Croatia.
Tripković, Mara; Francisković, Tanja; Grgić, Neda; Ercegović, Nela; Graovac, Mirjana; Zecević, Iva
2013-12-01
The aim of this research is to look into the roles of families' social situation and cohesion in adolescent auto-aggressiveness in Croatia. The research was conducted on a sample of Zagreb high school students which encompassed 701 pupils of both genders aged 14-19. The basic demographic data were obtained using the Structured Demographic and Family Data Questionnaire. Auto-aggressiveness was tested using a section of the Report on Youth Aged 11-18 and the Scale of Auto-destructiveness--SAD, whereas the family cohesion was tested with the Family Adaptability and Cohesion Evaluation Scales FACES III. The obtained results show differences according to the gender: girls are more prone to auto-aggressiveness than boys (t = -3.385, df = 565, p = 0.001) and girls more often show symptoms of destructiveness (t = -3.809, df = 637, p < 0.001) and anxiety (t = -6.562, df = 640, p < 0.001), while boys show pronounced aggressiveness (t = 2.655, df = 653, p = 0.008). Significant family factors associated with auto-aggressiveness are parents' marital status (chi2 = 18.039, df = 4, p = 0.001), their financial situation (F(2.548) = 4.604, p = 0.010), alcoholic father (chi2 = 9.270, df = 2, p = 0.010), mentally ill mother (t = 5.264, df = 541, p < 0.001), as well as mentally ill father (t = 4.744, df = 529, p < 0.001), and corporal punishment by mother (F(2.542) = 8.132, p < 0.001) or father (F(2.530) = 5.341, p = 0.005). Adolescents from split families show more auto-aggressiveness. Family cohesion appears to be considerably associated with auto-aggressiveness and the adolescents that see their families as less cohesive have more mental problems (chi2 = 29.98, df = 2, p < 0.001). There is a connection between auto-destructive behavior in adolescents and family factors. Knowledge of family's social situation and cohesion may help understand, prevent and treat auto-aggressiveness in adolescents.
Skalec, Tomasz; Górecka-Dolny, Agnieszka; Zieliński, Stanisław; Gibek, Mirosław; Stróżecki, Łukasz; Kübler, Andrzej
2017-01-01
The automatic control module of end-tidal volatile agents (EtC) was designed to reduce the consumption of anaesthetic gases, increase the stability of general anaesthesia and reduce the need for adjustments in the settings of the anaesthesia machine. The aim of this study was to verify these hypotheses. The course of general anaesthesia with the use of the EtC module was analysed for haemodynamic stability, depth of anaesthesia, end-expiratory concentration of anaesthetic, number of ventilator key presses, fentanyl supply, consumption of volatile agents and anaesthesia and operation times. These data were compared with the data obtained during general anaesthesia controlled manually and were processed with statistical tests. Seventy-four patients underwent general anaesthesia for scheduled operations. Group AUTO-ET (n = 35) was anaesthetized with EtC, and group MANUAL-ET (n = 39) was controlled manually. Both populations presented similar anaesthesia stability. No differences were noted in the time of anaesthesia, saturation up to MAC 1.0 or awakening. Data revealed no differences in mean EtAA or the fentanyl dose. The AUTO-ET group exhibited fewer key presses per minute, 0.0603 min⁻¹, whereas the MANUAL-ET exhibited a value of 0.0842 min⁻¹; P = 0.001. The automatic group consumed more anaesthetic and oxygen per minute (sevoflurane 0.1171 mL min⁻¹; IQR: 0.0503; oxygen 1.8286 mL min⁻¹, IQR: 1,3751) than MANUAL-ET (sevoflurane 0.0824 mL min⁻¹, IQR: 0.0305; oxygen 1,288 mL min⁻¹, IQR: 0,6517) (P = 0.0028 and P = 0.0171, respectively). Both methods are equally stable and safe for patients. The consumption of volatile agents was significantly increased in the AUTO-ET group. EtC considerably reduces the number of key presses.
[Oral diseases in auto-immune polyendocrine syndrome type 1].
Proust-Lemoine, Emmanuelle; Guyot, Sylvie
2017-09-01
Auto-immune polyendocrine syndrome type 1 (APS1) also called Auto-immune Polyendocrinopathy Candidiasis Ectodermal Dystrophy (APECED) is a rare monogenic childhood-onset auto-immune disease. This autosomal recessive disorder is caused by mutations in the auto-immune regulator (AIRE) gene, and leads to autoimmunity targeting peripheral tissues. There is a wide variability in clinical phenotypes in patients with APSI, with auto-immune endocrine and non-endocrine disorders, and chronic mucocutaneous candidiasis. These patients suffer from oral diseases such as dental enamel hypoplasia and candidiasis. Both are frequently described, and in recent series, enamel hypoplasia and candidiasis are even the most frequent components of APS1 together with hypoparathyroidism. Both often occur during childhood (before 5 years old for canrdidiasis, and before 15 years old for enamel hypoplasia). Oral candidiasis is recurrent all life long, could become resistant to azole antifungal after years of treatment, and be carcinogenic, leading to severe oral squamous cell carcinoma. Oral components of APS1 should be diagnosed and rigorously treated. Dental enamel hypoplasia and/or recurrent oral candidiasis in association with auto-immune diseases in a young child should prompt APS1 diagnosis. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Auto-fusion and the shaping of neurons and tubes.
Soulavie, Fabien; Sundaram, Meera V
2016-12-01
Cells adopt specific shapes that are necessary for specific functions. For example, some neurons extend elaborate arborized dendrites that can contact multiple targets. Epithelial and endothelial cells can form tiny seamless unicellular tubes with an intracellular lumen. Recent advances showed that cells can auto-fuse to acquire those specific shapes. During auto-fusion, a cell merges two parts of its own plasma membrane. In contrast to cell-cell fusion or macropinocytic fission, which result in the merging or formation of two separate membrane bound compartments, auto-fusion preserves one compartment, but changes its shape. The discovery of auto-fusion in C. elegans was enabled by identification of specific protein fusogens, EFF-1 and AFF-1, that mediate cell-cell fusion. Phenotypic characterization of eff-1 and aff-1 mutants revealed that fusogen-mediated fusion of two parts of the same cell can be used to sculpt dendritic arbors, reconnect two parts of an axon after injury, or form a hollow unicellular tube. Similar auto-fusion events recently were detected in vertebrate cells, suggesting that auto-fusion could be a widely used mechanism for shaping neurons and tubes. Copyright © 2016 Elsevier Ltd. All rights reserved.
Patterns of synchrony for feed-forward and auto-regulation feed-forward neural networks.
Aguiar, Manuela A D; Dias, Ana Paula S; Ferreira, Flora
2017-01-01
We consider feed-forward and auto-regulation feed-forward neural (weighted) coupled cell networks. In feed-forward neural networks, cells are arranged in layers such that the cells of the first layer have empty input set and cells of each other layer receive only inputs from cells of the previous layer. An auto-regulation feed-forward neural coupled cell network is a feed-forward neural network where additionally some cells of the first layer have auto-regulation, that is, they have a self-loop. Given a network structure, a robust pattern of synchrony is a space defined in terms of equalities of cell coordinates that is flow-invariant for any coupled cell system (with additive input structure) associated with the network. In this paper, we describe the robust patterns of synchrony for feed-forward and auto-regulation feed-forward neural networks. Regarding feed-forward neural networks, we show that only cells in the same layer can synchronize. On the other hand, in the presence of auto-regulation, we prove that cells in different layers can synchronize in a robust way and we give a characterization of the possible patterns of synchrony that can occur for auto-regulation feed-forward neural networks.
How time delay and network design shape response patterns in biochemical negative feedback systems.
Börsch, Anastasiya; Schaber, Jörg
2016-08-24
Negative feedback in combination with time delay can bring about both sustained oscillations and adaptive behaviour in cellular networks. Here, we study which design features of systems with delayed negative feedback shape characteristic response patterns with special emphasis on the role of time delay. To this end, we analyse generic two-dimensional delay differential equations describing the dynamics of biochemical signal-response networks. We investigate the influence of several design features on the stability of the model equilibrium, i.e., presence of auto-inhibition and/or mass conservation and the kind and/or strength of the delayed negative feedback. We show that auto-inhibition and mass conservation have a stabilizing effect, whereas increasing abruptness and decreasing feedback threshold have a de-stabilizing effect on the model equilibrium. Moreover, applying our theoretical analysis to the mammalian p53 system we show that an auto-inhibitory feedback can decouple period and amplitude of an oscillatory response, whereas the delayed feedback can not. Our theoretical framework provides insight into how time delay and design features of biochemical networks act together to elicit specific characteristic response patterns. Such insight is useful for constructing synthetic networks and controlling their behaviour in response to external stimulation.
NASA Astrophysics Data System (ADS)
Kim, Jeomoh; Ji, Mi-Hee; Detchprohm, Theeradetch; Dupuis, Russell D.; Fischer, Alec M.; Ponce, Fernando A.; Ryou, Jae-Hyun
2015-09-01
Unintentional incorporation of gallium (Ga) in InAlN layers grown with different molar flow rates of Group-III precursors by metalorganic chemical vapor deposition has been experimentally investigated. The Ga mole fraction in the InAl(Ga)N layer was increased significantly with the trimethylindium (TMIn) flow rate, while the trimethylaluminum flow rate controls the Al mole fraction. The evaporation of metallic Ga from the liquid phase eutectic system between the pyrolized In from injected TMIn and pre-deposited metallic Ga was responsible for the Ga auto-incorporation into the InAl(Ga)N layer. The theoretical calculation on the equilibrium vapor pressure of liquid phase Ga and the effective partial pressure of Group-III precursors based on growth parameters used in this study confirms the influence of Group-III precursors on Ga auto-incorporation. More Ga atoms can be evaporated from the liquid phase Ga on the surrounding surfaces in the growth chamber and then significant Ga auto-incorporation can occur due to the high equilibrium vapor pressure of Ga comparable to effective partial pressure of input Group-III precursors during the growth of InAl(Ga)N layer.
A Code Generation Approach for Auto-Vectorization in the Spade Compiler
NASA Astrophysics Data System (ADS)
Wang, Huayong; Andrade, Henrique; Gedik, Buğra; Wu, Kun-Lung
We describe an auto-vectorization approach for the Spade stream processing programming language, comprising two ideas. First, we provide support for vectors as a primitive data type. Second, we provide a C++ library with architecture-specific implementations of a large number of pre-vectorized operations as the means to support language extensions. We evaluate our approach with several stream processing operators, contrasting Spade's auto-vectorization with the native auto-vectorization provided by the GNU gcc and Intel icc compilers.
12. DOUBLEDAY AVENUE NEAR MUMMASBURG ROAD. NOTE TRUNCATED OBSERVATION TOWER ...
12. DOUBLEDAY AVENUE NEAR MUMMASBURG ROAD. NOTE TRUNCATED OBSERVATION TOWER AND ROAD SIGN VARIATIONS (CAST IRON PLACE NAME AT LEFT / AUTO TOUR SIGN AT RIGHT). ALSO NOTE CONCRETE BOLLARDS TO CONTROL PARKING. VIEW S. - Gettysburg National Military Park Tour Roads, Gettysburg, Adams County, PA
Jimenez-Zepeda, V H; Reece, D E; Trudel, S; Chen, C; Tiedemann, R; Kukreti, V
2015-02-01
The role of auto-SCT in the treatment of multiple myeloma (MM) in the era of novel agents continues to evolve. It is now clear that the depth of response and clinical outcomes have significantly improved as a result of the combination of these strategies. However, not all patients with MM who undergo auto-SCT are able to sustain a meaningful response and 20% of patients relapse shortly after auto-SCT. In this study, we aimed to assess the impact of early relapse (ER) after auto-SCT on OS for MM patients undergoing single auto-SCT who had received novel agent-based induction regimens. All consecutive patients with MM undergoing single auto-SCT from January 2002 to September 2012 who had novel induction therapy were evaluated. A total of 184 patients were identified. The median OS and PFS for the group of transplanted patients were 93 and 25.4 months, respectively. Median time to relapse was 17.2 months with 40% having relapsed at the time of analysis. ER (<12 months post auto-SCT) was seen in 27 (36%) out of 75 patients who had relapsed, and median OS was significantly shorter than in those with non-ER. Multivariate analysis showed ER as the major independent prognostic factor for OS. On the basis of these findings, we conclude that not only attainment of a good response, but sustainability of it, appears to be a major prognostic variable in MM in the era of novel therapy. Patients with ER post auto-SCT should biologically be characterized in prospective studies to better understand the mechanisms of resistance associated with this particular entity.
Carlucci, Annalisa; Ceriana, Piero; Mancini, Marco; Cirio, Serena; Pierucci, Paola; D'Artavilla Lupo, Nadia; Gadaleta, Felice; Morrone, Elisa; Fanfulla, Francesco
2015-01-01
Background: Ventilation with continuous positive airway pressure (CPAP) is the gold standard therapy for obstructive sleep apnea (OSA). However, it was recently suggested that a novel mode of ventilation, Bilevel-auto, could be equally effective in treating patients unable to tolerate CPAP. The aim of this study was to investigate the ability of Bilevel-auto to treat OSA patients whose nocturnal ventilatory disturbances are not completely corrected by CPAP. Methods: We enrolled 66 consecutive OSA patients, not responsive to (group A) or intolerant of (group B) CPAP treatment, after a full night of manual CPAP titration in a laboratory. Full polysomnography data and daytime sleepiness score were compared for each group in the three different conditions: basal, during CPAP, and during Bilevel-auto. Results: The apnea-hypopnea index decreased significantly during CPAP in both groups; however, in the group A, there was a further significant improvement during Bilevel-auto. The same trend was observed for oxygenation indices, while the distribution and the efficiency of sleep did not differ following the switch from CPAP to Bilevel-auto. Conclusions: This study confirmed the role of Bilevel-auto as an effective therapeutic alternative to CPAP in patients intolerant of this latter mode of ventilation. Moreover, extending the use of Bilevel-auto to those OSA patients not responsive to CPAP, we showed a significantly better correction of nocturnal respiratory disturbances. Citation: Carlucci A, Ceriana P, Mancini M, Cirio S, Pierucci P, D'Artavilla Lupo N, Gadaleta F, Morrone E, Fanfulla F. Efficacy of Bilevel-auto treatment in patients with obstructive sleep apnea not responsive to or intolerant of continuous positive airway pressure ventilation. J Clin Sleep Med 2015;11(9):981–985. PMID:25902825
Epperla, Narendranath; Shah, Namrata; Hamadani, Mehdi; Richardson, Kristin; Kapke, Jonathan T; Patel, Asmita; Teegavarapu, Sravanthi P; Carrum, George; Hari, Parameswaran N; Pingali, Sai R; Karmali, Reem; Fenske, Timothy S
2016-12-01
For patients with relapsed or refractory diffuse large B-cell lymphoma (DLBCL), autologous hematopoietic cell transplantation (auto-HCT) is commonly used. After auto-HCT, DLBCL patients are often monitored with surveillance imaging. However, there is little evidence to support this practice. We performed a multicenter retrospective study of DLBCL patients who underwent auto-HCT (n = 160), who experienced complete remission after transplantation, and who then underwent surveillance imaging. Of these, only 45 patients experienced relapse after day +100 after auto-HCT, with relapse detected by routine imaging in 32 (71%) and relapse detected clinically in 13 (29%). Baseline patient characteristics were similar between the 2 groups. Comparing the radiographic and clinically detected relapse groups, the median time from diagnosis to auto-HCT (389 days vs. 621 days, P = .06) and the median follow-up after auto-HCT (2464 days vs. 1593 days P = .60) were similar. The median time to relapse after auto-HCT was 191 days in radiographically detected relapses compared to 492 days in clinically detected relapses (P = .35), and median postrelapse survival was 359 days in such patients compared to 123 days in patients with clinically detected relapse (P = .36). However, the median posttransplantation overall survival was not significantly different for patients with relapse detected by routine imaging versus relapse detected clinically (643 vs. 586 days, P = .68). A majority (71%) of DLBCL relapses after auto-HCT are detected by routine surveillance imaging. Overall, there appears to be limited utility for routine imaging after auto-HCT except in select cases where earlier detection and salvage therapy with allogeneic HCT is a potential option. Copyright © 2016 Elsevier Inc. All rights reserved.
Appeltshauser, Luise; Weishaupt, Andreas; Sommer, Claudia; Doppler, Kathrin
2017-01-01
Inflammatory neuropathies associated with auto-antibodies against paranodal proteins like contactin-1 are reported to respond poorly to treatment with intravenous immunoglobulins (IVIG). A reason might be that IVIG interacts with the complement pathway and these auto-antibodies often belong to the IgG4 subclass that does not activate complement. However, some patients do show a response to IVIG, especially at the beginning of the disease. This corresponds with the finding of coexisting IgG subclasses IgG1, IgG2 and IgG3. We therefore aimed to investigate complement deposition and activation by samples of three patients with anti-contactin-1 IgG auto-antibodies of different subclasses as a potential predictor for response to IVIG. Complement deposition and activation was measured by cell binding and ELISA based assays, and the effect of IVIG on complement deposition was assessed by addition of different concentrations of IVIG. Binding of anti-contactin-1 auto-antibodies of all three patients induced complement deposition and activation with the strongest effect shown by the serum of a patient with predominance of IgG3 auto-antibodies. IVIG led to a reduction of complement deposition in a dose-dependent manner, but did not reduce binding of auto-antibodies to contactin-1. We conclude that complement deposition may contribute to the pathophysiology of anti-contactin-1 associated neuropathy, particularly in patients with predominance of the IgG3 subclass. The proportion of different auto-antibody subclasses may be a predictor for the response to IVIG in patients with auto-antibodies against paranodal proteins. Copyright © 2016 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Mireles, S. Raymond
Self-Programmed Counseling, the instructor's guidance, and Self-Programmed Control (SPC), the student's response, was initially developed by Title III Project USTED (United Students and Teachers for Educational Development) for Mexican American students on academic probation to use on a non-credit, special group counseling basis. As part of a…
Nonlinear Control Theory for Missile Autopilot Design.
1987-04-24
minimum-time controller which includes constraints on both controls and angle-of-attack is developed and an example is given. -12- - - -~ *% PO PmCF E- A...constructed. In this case, some ideas from robotics on minimum-time trajectory planning under path constraints (see, e.g., Rajan (1985), Sahar and...Auto Cont., Vol. AC-29, No. 4, p. 361. Rajan, V.T. (1985), "Minimum-Time Trajectory Planning ", Proc IEEE Kobotics and Automation Conf., St. Louis. Reed
Forcina, Alessandra; Lorentino, Francesca; Marasco, Vincenzo; Oltolini, Chiara; Marcatti, Magda; Greco, Raffaella; Lupo-Stanghellini, Maria Teresa; Carrabba, Matteo; Bernardi, Massimo; Peccatori, Jacopo; Corti, Consuelo; Ciceri, Fabio
2018-03-02
Multidrug-resistant Gram-negative bacteria (MDR-GNB) are an emerging cause of morbidity and mortality after hematopoietic stem cell transplantation (HSCT). Three-hundred forty-eight consecutive patients transplanted at our hospital from July 2012 to January 2016 were screened for a pretransplant MDR-GNB colonization and evaluated for clinical outcomes. A pretransplant MDR-GNB colonization was found in 16.9% of allo-HSCT and in 9.6% of auto-HSCT recipients. Both in auto- and in allo-HSCT, carriers of a MDR-GNB showed no significant differences in overall survival (OS), transplant-related mortality (TRM), or infection-related mortality (IRM) compared with noncarriers. OS at 2 years for carriers compared with noncarriers was 85% versus 81% (P = .262) in auto-HSCT and 50% versus 43% (P = .091) in allo-HSCT. TRM at 2 years was 14% versus 5% (P = .405) in auto-HSCT and 31% versus 25% (P = .301) in allo-HSCT. IRM at 2 years was 14% versus 2% (P = .142) in auto-HSCT and 23% versus 14% (P = .304) in allo-HSCT. In multivariate analysis, only grade III to IV acute graft-versus-host disease was an independent factor for reduced OS (P < .001) and increased TRM (P < .001) and IRM (P < .001). During the first year after transplant, we collected 73 GNB bloodstream infectious (BSI) episodes in 54 patients, 42.4% of which sustained by a MDR-GNB. Rectal swabs positivity associated with the pathogen causing subsequent MDR-GNB BSI episodes in 13 of 31 (41.9%). Overall, OS at 4 months from MDR-GNB BSI episode onset was of 67.9%, with a 14-day attributed mortality of 12.9%, not being significantly different between carriers and noncarriers (P = .207). We conclude that in this extended single-center experience, a pretransplant MDR-GNB colonization did not significantly influence OS, TRM, and IRM both in auto- and allo-HSCT settings and that MDR-GNB attributed mortality can be controlled in carriers when an early pre-emptive antimicrobial therapy is started in case of neutropenic fever. Copyright © 2018 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
Dreger, Peter; Döhner, Hartmut; McClanahan, Fabienne; Busch, Raymonde; Ritgen, Matthias; Greinix, Hildegard; Fink, Anna-Maria; Knauf, Wolfgang; Stadler, Michael; Pfreundschuh, Michael; Dührsen, Ulrich; Brittinger, Günter; Hensel, Manfred; Schetelig, Johannes; Winkler, Dirk; Bühler, Andreas; Kneba, Michael; Schmitz, Norbert; Hallek, Michael; Stilgenbauer, Stephan
2012-05-24
The CLL3 trial was designed to study intensive treatment including autologous stem cell transplantation (autoSCT) as part of first-line therapy in patients with chronic lymphocytic leukemia (CLL). Here, we present the long-term outcome of the trial with particular focus on the impact of genomic risk factors, and we provide a retrospective comparison with patients from the fludarabine-cyclophosphamide-rituximab (FCR) arm of the German CLL Study Group (GCLLSG) CLL8 trial. After a median observation time of 8.7 years (0.3-12.3 years), median progression-free survival (PFS), time to retreatment, and overall survival (OS) of 169 evaluable patients, including 38 patients who did not proceed to autoSCT, was 5.7, 7.3, and 11.3 years, respectively. PFS and OS were significantly reduced in the presence of 17p- and of an unfavorable immunoglobulin heavy variable chain mutational status, but not of 11q-. Five-year nonrelapse mortality was 6.5%. When 110 CLL3 patients were compared with 126 matched patients from the FCR arm of the CLL8 trial, 4-year time to retreatment (75% vs 77%) and OS (86% vs 90%) was similar despite a significant benefit for autoSCT in terms of PFS. In summary, early treatment intensification including autoSCT can provide very effective disease control in poor-risk CLL, although its clinical benefit in the FCR era remains uncertain. The trial has been registered with www.clinicaltrials.gov as NCT00275015.
Methods on observation of fluorescence micro-imaging for microalgae
NASA Astrophysics Data System (ADS)
Ou, Lin; Zhuang, Hui-ru; Chen, Rong; Lei, Jin-pin; Liao, Xiao-hua; Lin, Wen-suo
2007-11-01
Objective: Auto-fluorescence micro-imaging of microalgae are observed by using of laser scanning confocal microscopy (LSCM) and fluorescence microscopy, so as to investigate the effect of auto fluorescence alteration on growth of irradiated microalgae irradiated, meanwhile, the method of microalgae cells stained also to be studied. Methods: Platymonas subcordiformis, Phaeodactylum tricormutum and Isochyrsis zhanjiangensis cells are stained with acridine orange, and observed by fluorescence microscopy; the three types microalgae mentioned above are irradiated by Nd:YAP laser with 10w at 1341nm, irradiating time:12s, 30s, 35s and 55s, than to be cultured 6 days, and the auto fluorescence images and fluorescence spectra of algae cells are obtained by LSCM on lambda scan mode, at excitation 488nm (Ar + laser). Results: It is showed that the shapes and the structural features of microalgae cells stained can be seen clearly, and the cytoplasm and nucleus also can be observed. The chloroplasts in cell is bigger on promoting effects, conversely, it is to be mutilated, deformation and shrink. Contrast to the CK, the peak positions of fluorescence of algae cells irradiated is similar to the whole while the peak light intensity alters. On irradiation of promoting dose, however, the auto fluorescence intensity is enhanced more than control. Conclusions: The method of cell stained can be used to observed genetic material in microalgae. There are obvious effects for laser irradiating to chloroplasts in cells, the bigger chloroplasts the greater fluorescence intensity. Physiological incentive effects of microalgae irradiated can be given expression on fluorescence characteristics and fluorescence intensity alteration of cells.
Global reaction mechanism for the auto-ignition of full boiling range gasoline and kerosene fuels
NASA Astrophysics Data System (ADS)
Vandersickel, A.; Wright, Y. M.; Boulouchos, K.
2013-12-01
Compact reaction schemes capable of predicting auto-ignition are a prerequisite for the development of strategies to control and optimise homogeneous charge compression ignition (HCCI) engines. In particular for full boiling range fuels exhibiting two stage ignition a tremendous demand exists in the engine development community. The present paper therefore meticulously assesses a previous 7-step reaction scheme developed to predict auto-ignition for four hydrocarbon blends and proposes an important extension of the model constant optimisation procedure, allowing for the model to capture not only ignition delays, but also the evolutions of representative intermediates and heat release rates for a variety of full boiling range fuels. Additionally, an extensive validation of the later evolutions by means of various detailed n-heptane reaction mechanisms from literature has been presented; both for perfectly homogeneous, as well as non-premixed/stratified HCCI conditions. Finally, the models potential to simulate the auto-ignition of various full boiling range fuels is demonstrated by means of experimental shock tube data for six strongly differing fuels, containing e.g. up to 46.7% cyclo-alkanes, 20% napthalenes or complex branched aromatics such as methyl- or ethyl-napthalene. The good predictive capability observed for each of the validation cases as well as the successful parameterisation for each of the six fuels, indicate that the model could, in principle, be applied to any hydrocarbon fuel, providing suitable adjustments to the model parameters are carried out. Combined with the optimisation strategy presented, the model therefore constitutes a major step towards the inclusion of real fuel kinetics into full scale HCCI engine simulations.
EMISSIONS FROM COATINGS USED IN THE AUTO REFINISHING INDUSTRY
The report presents results of EPA Methods 24 and 311 analyses of the volatile organic compound (VOC) content of selected auto refinishing coatings and their components that are sold by the five major auto coating manufacturers. These analyses were undertaken to determine the acc...
2012-01-01
Background Structured association mapping is proving to be a powerful strategy to find genetic polymorphisms associated with disease. However, these algorithms are often distributed as command line implementations that require expertise and effort to customize and put into practice. Because of the difficulty required to use these cutting-edge techniques, geneticists often revert to simpler, less powerful methods. Results To make structured association mapping more accessible to geneticists, we have developed an automatic processing system called Auto-SAM. Auto-SAM enables geneticists to run structured association mapping algorithms automatically, using parallelization. Auto-SAM includes algorithms to discover gene-networks and find population structure. Auto-SAM can also run popular association mapping algorithms, in addition to five structured association mapping algorithms. Conclusions Auto-SAM is available through GenAMap, a front-end desktop visualization tool. GenAMap and Auto-SAM are implemented in JAVA; binaries for GenAMap can be downloaded from http://sailing.cs.cmu.edu/genamap. PMID:22471660
A Real-Time Non-invasive Auto-bioluminescent Urinary Bladder Cancer Xenograft Model.
John, Bincy Anu; Xu, Tingting; Ripp, Steven; Wang, Hwa-Chain Robert
2017-02-01
The study was to develop an auto-bioluminescent urinary bladder cancer (UBC) xenograft animal model for pre-clinical research. The study used a humanized, bacteria-originated lux reporter system consisting of six (luxCDABEfrp) genes to express components required for producing bioluminescent signals in human UBC J82, J82-Ras, and SW780 cells without exogenous substrates. Immune-deficient nude mice were inoculated with Lux-expressing UBC cells to develop auto-bioluminescent xenograft tumors that were monitored by imaging and physical examination. Lux-expressing auto-bioluminescent J82-Lux, J82-Ras-Lux, and SW780-Lux cell lines were established. Xenograft tumors derived from tumorigenic Lux-expressing auto-bioluminescent J82-Ras-Lux cells allowed a serial, non-invasive, real-time monitoring by imaging of tumor development prior to the presence of palpable tumors in animals. Using Lux-expressing auto-bioluminescent tumorigenic cells enabled us to monitor the entire course of xenograft tumor development through tumor cell implantation, adaptation, and growth to visible/palpable tumors in animals.
NASA Astrophysics Data System (ADS)
Jiang, Jingtao; Sui, Rendong; Shi, Yan; Li, Furong; Hu, Caiqi
In this paper 3-D models of combined fixture elements are designed, classified by their functions, and saved in computer as supporting elements library, jointing elements library, basic elements library, localization elements library, clamping elements library, and adjusting elements library etc. Then automatic assembly of 3-D combined checking fixture for auto-body part is presented based on modularization theory. And in virtual auto-body assembly space, Locating constraint mapping technique and assembly rule-based reasoning technique are used to calculate the position of modular elements according to localization points and clamp points of auto-body part. Auto-body part model is transformed from itself coordinate system space to virtual assembly space by homogeneous transformation matrix. Automatic assembly of different functional fixture elements and auto-body part is implemented with API function based on the second development of UG. It is proven in practice that the method in this paper is feasible and high efficiency.
The accuracy of autotitrating CPAP-determined residual apnea-hypopnea index.
Cilli, Aykut; Uzun, Rusen; Bilge, Ugur
2013-03-01
Autotitrating continuous positive airway pressure (auto-CPAP) devices not only titrate CPAP pressures but also measure residual respiratory events. The aim of the present study was to determine the accuracy of auto-CPAP-derived residual apnea-hypopnea index (AHI). We studied 137 consecutive patients (72.3% men) with obstructive sleep apnea from January 2008 to December 2010 who underwent in-laboratory overnight polysomnography (PSG) using auto-CPAP. We excluded patients with comorbidities like congestive heart disease, chronic obstructive pulmonary disease, or hypoventilation syndromes and patients with central sleep apnea. Residual AHI obtained from the auto-CPAP device by smart card (CPAP-AHI) was compared simultaneously with AHI from an overnight PSG on auto-CPAP (PSG-AHI) using Bland-Altman analysis and Wilcoxon signed-rank test. The mean AHI on the diagnostic study was 45.08 ± 1.8. During the titration, auto-CPAP markedly suppressed the respiratory events (PSG-AHI, 3.40 ± 0.20). On the other hand, CPAP-AHI was 3.35 ± 0.17. Bland-Altman analysis showed good agreement between auto-CPAP-AHI and PSG-AHI (AHI mean difference of 0.05, and the limits of agreement for the AHI were from +4.9 to -4.8). Two methods have also been compared with paired samples t test and no statistically significant difference was found (p > 0.05). Auto-CPAP can identify residual respiratory events equivalent to the use of PSG in a selected population.
Carlucci, Annalisa; Ceriana, Piero; Mancini, Marco; Cirio, Serena; Pierucci, Paola; D'Artavilla Lupo, Nadia; Gadaleta, Felice; Morrone, Elisa; Fanfulla, Francesco
2015-09-15
Ventilation with continuous positive airway pressure (CPAP) is the gold standard therapy for obstructive sleep apnea (OSA). However, it was recently suggested that a novel mode of ventilation, Bilevel-auto, could be equally effective in treating patients unable to tolerate CPAP. The aim of this study was to investigate the ability of Bilevel-auto to treat OSA patients whose nocturnal ventilatory disturbances are not completely corrected by CPAP. We enrolled 66 consecutive OSA patients, not responsive to (group A) or intolerant of (group B) CPAP treatment, after a full night of manual CPAP titration in a laboratory. Full polysomnography data and daytime sleepiness score were compared for each group in the three different conditions: basal, during CPAP, and during Bilevel-auto. The apnea-hypopnea index decreased significantly during CPAP in both groups; however, in the group A, there was a further significant improvement during Bilevel-auto. The same trend was observed for oxygenation indices, while the distribution and the efficiency of sleep did not differ following the switch from CPAP to Bilevel-auto. This study confirmed the role of Bilevel-auto as an effective therapeutic alternative to CPAP in patients intolerant of this latter mode of ventilation. Moreover, extending the use of Bilevel-auto to those OSA patients not responsive to CPAP, we showed a significantly better correction of nocturnal respiratory disturbances. © 2015 American Academy of Sleep Medicine.
Akhtar, S; Youssef, I; Soudy, H; Elhassan, T A M; Rauf, S M; Maghfoor, I
2015-12-01
Data are limited regarding the prevalence of menstrual cycles and pregnancies after high-dose chemotherapy (HDC) and auto-stem cell transplantation (SCT). Female patients who underwent HDC auto-SCT for non-Hodgkin and Hodgkin lymphoma (1997-2012) were reviewed. The selection criteria were as follows: (1) alive without disease 12 and 24 months after auto-SCT for menstrual cycles and pregnancy, respectively, (2) age <40 years at auto-SCT, and (3) no primary infertility. One-hundred and seventy-six females underwent single auto-SCT. Eighty-nine were eligible for menstrual cycles and pregnancy analysis. Median age at auto-SCT was 25 years (14-40 years), at pregnancy 27 years (20-37 years), median follow-up 65 months (range 24-190). Regular menstrual-cycles resumed in 56/89 patients (63%). Increasing age (P=0.02) and number of prior chemotherapy cycles (P=0.02) are associated with higher risk of amenorrhea. Forty patients tried to get pregnant, 26 (65%) became pregnant 50 times: 43 (86%) live birth, 7 (14%) miscarriage and 2/50 had birth defects. Twenty-four patients practiced breastfeeding (median duration 4 months (1-24 months)). Enough breast milk production was reported 62.5% vs 100% in those patients who did or did not receive above the diaphragm radiation therapy, respectively, (P=0.066). Our data highlights significantly higher than perceived incidence of menstrual cycle resumption, successful pregnancies and breastfeeding after HDC auto-SCT.
Gan, Kok Beng; Azeez, Dhifaf; Umat, Cila; Ali, Mohd Alauddin Mohd; Wahab, Noor Alaudin Abdul; Mukari, Siti Zamratol Mai-Sarah
2012-10-01
Hearing screening is important for the early detection of hearing loss. The requirements of specialized equipment, skilled personnel, and quiet environments for valid screening results limit its application in schools and health clinics. This study aimed to develop an automated hearing screening kit (auto-kit) with the capability of realtime noise level monitoring to ensure that the screening is performed in an environment that conforms to the standard. The auto-kit consists of a laptop, a 24-bit resolution sound card, headphones, a microphone, and a graphical user interface, which is calibrated according to the American National Standards Institute S3.6-2004 standard. The auto-kit can present four test tones (500, 1000, 2000, and 4000 Hz) at 25 or 40 dB HL screening cut-off level. The clinical results at 40 dB HL screening cut-off level showed that the auto-kit has a sensitivity of 92.5% and a specificity of 75.0%. Because the 500 Hz test tone is not included in the standard hearing screening procedure, it can be excluded from the auto-kit test procedure. The exclusion of 500 Hz test tone improved the specificity of the auto-kit from 75.0% to 92.3%, which suggests that the auto-kit could be a valid hearing screening device. In conclusion, the auto-kit may be a valuable hearing screening tool, especially in countries where resources are limited.
Health needs and concerns of male adolescents.
Pinch, W J; Heck, M; Vinal, D
1986-01-01
Lifestyle factors established within the family help determine health-care functioning. Adolescents first may be challenged to meet their own health needs as freshmen in college. A 153-item questionnaire was utilized to examine concerns in the areas of alcohol and other drug use, auto safety, weight and dieting, smoking, sexuality, coping and stress, and selection and utilization of health-care services. One hundred fifty-nine male college students responded. Major problems with alcohol use, auto safety, weight control, stress and sexuality were identified. Positive lifestyle factors that were strongly supported included regular exercise, nonsmoking, regular medical and dental checkups, and the development of some support systems to cope with stress. Health-care services designated by respondents to meet their own needs were significantly different from those services they pointed out as needed for their peers.
Modelling and Closed-Loop System Identification of a Quadrotor-Based Aerial Manipulator
NASA Astrophysics Data System (ADS)
Dube, Chioniso; Pedro, Jimoh O.
2018-05-01
This paper presents the modelling and system identification of a quadrotor-based aerial manipulator. The aerial manipulator model is first derived analytically using the Newton-Euler formulation for the quadrotor and Recursive Newton-Euler formulation for the manipulator. The aerial manipulator is then simulated with the quadrotor under Proportional Derivative (PD) control, with the manipulator in motion. The simulation data is then used for system identification of the aerial manipulator. Auto Regressive with eXogenous inputs (ARX) models are obtained from the system identification for linear accelerations \\ddot{X} and \\ddot{Y} and yaw angular acceleration \\ddot{\\psi }. For linear acceleration \\ddot{Z}, and pitch and roll angular accelerations \\ddot{θ } and \\ddot{φ }, Auto Regressive Moving Average with eXogenous inputs (ARMAX) models are identified.
DOT National Transportation Integrated Search
1979-11-01
This report traces the development of the three-way catalytic converter system from its origins in automaker and chemical firm research in the 1950s, to present plans preparing the system to be the auto exhaust emission control device most widely use...
Feasibility Study of a Vision-Based Landing System for Unmanned Fixed-Wing Aircraft
2017-06-01
International Journal of Computer Science and Network Security 7 no. 3: 112–117. Accessed April 7, 2017. http://www.sciencedirect.com/science/ article /pii...the feasibility of applying computer vision techniques and visual feedback in the control loop for an autonomous system. This thesis examines the...integration into an autonomous aircraft control system. 14. SUBJECT TERMS autonomous systems, auto-land, computer vision, image processing
Philip A. Araman; Janice K. Wiedenbeck
1995-01-01
Automated lumber grading and yield optimization using computer controlled saws will be plausible for hardwoods if and when lumber scanning systems can reliably identify all defects by type. Existing computer programs could then be used to grade the lumber, identify the best cut-up solution, and control the sawing machines. The potential value of a scanning grading...
Design of a new controller to treat the obstructive sleep apnea
NASA Astrophysics Data System (ADS)
Netzel, Thomas
2002-06-01
The obstructive sleep apnoea (OSA) is a sleep related breathing disorder caused by a relaxation of the upper airway structure during the sleep that leads to a complete closure of the upper airway. The most successful therapy is the nasal continuous positive airway pressure (nCPAP) treatment that keeps the airway opened. More recent devices use an automatic adaptation of the applied pressure. Either the forced oscillation technique (FOT) or the evaluation of the inspiration flow contour are used to evaluate the severity of obstructions. Both methods have disadvantages that may lead to wrong applied pressures. Based on the precise measurement of airflow and mask pressure during nCPAP with a Weinmann SOMNOsmart and additional polysomnography a new parameter set is presented that uses the advantage of both methods to detect the obstructive sleep apnoea. To evaluate the applicability of this parameter set to control Auto-nCPAP-devices a fuzzy-controller is designed under MATLAB/Simulink using an A/D-D/A-converter to control the blower of the SOMNOsmart during Auto-nCPAP-therapy. Obstructive events are detected and treated with a rise of nCPAP-pressure depending on the inspiratory flow requirement. The pressure is lowered after the end of flow limited phases. Although temporary low pressures no oxygen desaturation is recognized by the pulse oxymeter.
Auto Body Repair. Supplementary Units. Instructor Key and Student Units.
ERIC Educational Resources Information Center
Daniel, Linda; Muench, James F., Ed.
These supplementary units are designed to help students with special needs learn and apply auto body repair skills. The material specifically supplements the Auto Body Repair Curriculum Guide (University of Missouri-Columbia 1988), and is intended for instructors serving the occupational needs of various categories of disadvantaged and handicapped…
46 CFR 28.875 - Radar, depth sounding, and auto-pilot.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 1 2013-10-01 2013-10-01 false Radar, depth sounding, and auto-pilot. 28.875 Section 28.875 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.875 Radar, depth sounding, and auto-pilot...
46 CFR 28.875 - Radar, depth sounding, and auto-pilot.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 1 2014-10-01 2014-10-01 false Radar, depth sounding, and auto-pilot. 28.875 Section 28.875 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.875 Radar, depth sounding, and auto-pilot...
12 CFR 222.75 - Rules of construction.
Code of Federal Regulations, 2011 CFR
2011-01-01
... of an automobile. If the auto dealer is the person to whom the loan obligation is initially payable, such as where the auto dealer is the original creditor under a retail installment sales contract, the auto dealer must provide the risk-based pricing notice to the consumer (or satisfy the requirements for...
12 CFR 222.75 - Rules of construction.
Code of Federal Regulations, 2013 CFR
2013-01-01
... of an automobile. If the auto dealer is the person to whom the loan obligation is initially payable, such as where the auto dealer is the original creditor under a retail installment sales contract, the auto dealer must provide the risk-based pricing notice to the consumer (or satisfy the requirements for...
12 CFR 222.75 - Rules of construction.
Code of Federal Regulations, 2014 CFR
2014-01-01
... of an automobile. If the auto dealer is the person to whom the loan obligation is initially payable, such as where the auto dealer is the original creditor under a retail installment sales contract, the auto dealer must provide the risk-based pricing notice to the consumer (or satisfy the requirements for...
46 CFR 185.360 - Use of auto pilot.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Use of auto pilot. 185.360 Section 185.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.360 Use of auto pilot. Whenever an automatic pilot is...
46 CFR 131.960 - Use of auto-pilot.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Use of auto-pilot. 131.960 Section 131.960 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Miscellaneous § 131.960 Use of auto-pilot. When the automatic pilot is used in areas of high traffic density...
46 CFR 185.360 - Use of auto pilot.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Use of auto pilot. 185.360 Section 185.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.360 Use of auto pilot. Whenever an automatic pilot is...
46 CFR 131.960 - Use of auto-pilot.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Use of auto-pilot. 131.960 Section 131.960 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Miscellaneous § 131.960 Use of auto-pilot. When the automatic pilot is used in areas of high traffic density...
46 CFR 28.875 - Radar, depth sounding, and auto-pilot.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 1 2012-10-01 2012-10-01 false Radar, depth sounding, and auto-pilot. 28.875 Section 28.875 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.875 Radar, depth sounding, and auto-pilot...
46 CFR 131.960 - Use of auto-pilot.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Use of auto-pilot. 131.960 Section 131.960 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Miscellaneous § 131.960 Use of auto-pilot. When the automatic pilot is used in areas of high traffic density...
12 CFR 222.75 - Rules of construction.
Code of Federal Regulations, 2012 CFR
2012-01-01
... of an automobile. If the auto dealer is the person to whom the loan obligation is initially payable, such as where the auto dealer is the original creditor under a retail installment sales contract, the auto dealer must provide the risk-based pricing notice to the consumer (or satisfy the requirements for...
46 CFR 185.360 - Use of auto pilot.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Use of auto pilot. 185.360 Section 185.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.360 Use of auto pilot. Whenever an automatic pilot is...
Programmable Applications: Interpreter Meets Interface
1991-10-01
ics program written for professional architects and designers, and including a huge library of files written in AutoLisp , a "design-enriched" Lisp... AutoLisp procedures). The choice of Lisp as a base language is a happy one for AutoCAD; the application has clearly benefitted from the contribution
46 CFR 28.875 - Radar, depth sounding, and auto-pilot.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Radar, depth sounding, and auto-pilot. 28.875 Section 28.875 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.875 Radar, depth sounding, and auto-pilot...
46 CFR 131.960 - Use of auto-pilot.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Use of auto-pilot. 131.960 Section 131.960 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Miscellaneous § 131.960 Use of auto-pilot. When the automatic pilot is used in areas of high traffic density...
46 CFR 185.360 - Use of auto pilot.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Use of auto pilot. 185.360 Section 185.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.360 Use of auto pilot. Whenever an automatic pilot is...
Auto Collision Technician: An Instructional Guide for Teachers.
ERIC Educational Resources Information Center
Ohio State Univ., Columbus. Vocational Instructional Materials Lab.
This guide is designed to help teachers in auto collision technician programs for grades 11 and 12 teach the critical competencies of the program. The critical competencies covered are the High Priority-Individual (HP-I) competencies in Ohio's Occupational Competency Assessment Profile (OCAP) for Auto Collision Technician. HP-I competencies are…
New Technologies, New Curricula.
ERIC Educational Resources Information Center
Speidel, Gisela E.
1995-01-01
This article describes the AutoCAD Laboratory at Hawaii's Kamehameha Secondary Schools, offering the perspective of the AutoCAD instructor and Technology Department Head, looking at a day in the AutoCAD Laboratory, and explaining how teaching students about computer-assisted design and drafting can prepare them for college or careers. (SM)
46 CFR 185.360 - Use of auto pilot.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Use of auto pilot. 185.360 Section 185.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.360 Use of auto pilot. Whenever an automatic pilot is...
46 CFR 131.960 - Use of auto-pilot.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Use of auto-pilot. 131.960 Section 131.960 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Miscellaneous § 131.960 Use of auto-pilot. When the automatic pilot is used in areas of high traffic density...
1991-03-21
sectional representation of the spatial figure can be correctly determined. 6 The AutoLisp language system in the AutoCAD software provides the most...softwares are developed on the 32-bit machines and little progress has been reported for the 16-bit machines. Even the AutoCAD is a two-ard-a-half... AutoCAD software as the basis, developed the design package of 3-D cartridge valve blocks on IM PC/AT. To realize the 3-D displaying of cartridge valves
Caballero Mesa, J M; Alonso Marrero, S; González Weller, D M; Afonso Gutiérrez, V L; Rubio Armendariz, C; Hardisson de la Torre, A
2006-01-01
To satisfactorily implement the critical hazards and check points analysis. Tenerife Island Subjects: 15 industries visits to gofio-manufacturing industries were done with the aim of giving advice to employers and workers, and thereafter, the intervention was assessed verifying the hygiene and sanitary conditions of the industry and the correct application of the established auto-control system. After the advising intervention, we observed that certain parameters taken into account from the hygiene and sanitary perspective have been corrected, such as modifying the facilities to adapt them to in force regulations, or asking the suppliers to certify raw materials. With regards to food production process, the intervention was effective in such a way that more than have of the industries reduced the time of those phases with higher contamination susceptibility and to carry out the control registries that were established. All industries implemented the auto-control system by means of registration charts of each one of the elaboration phases. 86% of the industries have introduced more hygienic materials. 60% implemented a reduction in intermediate times of production phases. 26% perfmored some obsolete machinery replacement modernaizing the facilities.
NASA Astrophysics Data System (ADS)
Bell, L. R.; Dowling, J. A.; Pogson, E. M.; Metcalfe, P.; Holloway, L.
2017-01-01
Accurate, efficient auto-segmentation methods are essential for the clinical efficacy of adaptive radiotherapy delivered with highly conformal techniques. Current atlas based auto-segmentation techniques are adequate in this respect, however fail to account for inter-observer variation. An atlas-based segmentation method that incorporates inter-observer variation is proposed. This method is validated for a whole breast radiotherapy cohort containing 28 CT datasets with CTVs delineated by eight observers. To optimise atlas accuracy, the cohort was divided into categories by mean body mass index and laterality, with atlas’ generated for each in a leave-one-out approach. Observer CTVs were merged and thresholded to generate an auto-segmentation model representing both inter-observer and inter-patient differences. For each category, the atlas was registered to the left-out dataset to enable propagation of the auto-segmentation from atlas space. Auto-segmentation time was recorded. The segmentation was compared to the gold-standard contour using the dice similarity coefficient (DSC) and mean absolute surface distance (MASD). Comparison with the smallest and largest CTV was also made. This atlas-based auto-segmentation method incorporating inter-observer variation was shown to be efficient (<4min) and accurate for whole breast radiotherapy, with good agreement (DSC>0.7, MASD <9.3mm) between the auto-segmented contours and CTV volumes.
Co-autodisplay of Z-domains and bovine caseins on the outer membrane of E. coli.
Yoo, Gu; Saenger, Thorsten; Bong, Ji-Hong; Jose, Joachim; Kang, Min-Jung; Pyun, Jae-Chul
2015-12-01
In this work, two proteins, Z-domains and bovine casein, were auto-displayed on the outer membrane of the same Escherichia coli cells by co-transformation of two different auto-display vectors. On the basis of SDS-PAGE densitometry, Z-domains and bovine casein were expressed at 3.12 × 10⁵ and 1.55 × 10⁵ proteins/E. coli cell, respectively. The co-auto-displayed Z-domains had antibody-binding activity and the bovine casein had adhesive properties. E. coli with co-auto-displayed proteins were analyzed by fluorescence assisted cell sorting (FACS). E. coli with co-auto-displayed Z-domains and bovine casein aggregated due to hydrophobic interaction. For application to immunoassays, the Z-domain activity was estimated after (1) immobilizing the E. coli and (2) forming an OM layer. E. coli with co-auto-displayed two proteins that were immobilized on a polystyrene microplate had the same antibody-binding activity as did E. coli with auto-displayed Z-domains only. The OM layer from the co-transformed E. coli had Z-domains and bovine casein expressed at a 1:2 ratio from antibody-binding activity measurements. Copyright © 2015 Elsevier B.V. All rights reserved.
The auto-amputated adnexa: a review of findings in a pediatric population.
Focseneanu, Mariel A; Omurtag, Kenan; Ratts, Valerie S; Merritt, Diane F
2013-12-01
To quantify our experience and that of the literature with diagnosis and management of the auto-amputated adnexa in a pediatric population. Case series and literature review. Tertiary care medical center. Case series of pediatric patients (<18 years of age) with surgically documented adnexal auto-amputation collected from our medical center and the literature. None. Auto-amputated adnexa. In addition to the 3 cases discussed from our institution, 91 cases of auto-amputated adnexa were identified in the literature dating back to 1943, for a total of 94 cases. Forty-nine percent (46/94) of the cases involved girls in a pediatric population (<18 years of age). Of these, the majority (n = 26) were identified in a subgroup of girls who were diagnosed with an adnexal cyst by antenatal ultrasound. Most of these neonates were asymptomatic at birth or had a palpable abdominal mass (n = 6) and at the time of surgical exploration were found to have an auto-amputated adnexa. 34 out of 46 cases were analyzed in detail. The right adnexa were involved in 56% of the cases. The most common presenting complaint verbalized by the older girls was pain; however, 8 cases were identified in asymptomatic girls undergoing unrelated diagnostic testing. The auto-amputated adnexa is a rare finding in the pediatric population, but it must be considered as a possible explanation for the incidental finding of absence of the fallopian tube or ovary in the subgroup of patients who undergo surgery for any reason. Patients with an antecedent history of pelvic pain either chronic or intermittent in nature may be diagnosed with torsion or less frequently auto-amputation of the adnexa. A fetal "pelvic mass" or "ovarian cyst" may predispose the adnexa to torsion and subsequent auto-amputation either in-utero or post-delivery. Many of these antenatally diagnosed cysts and even subsequent auto-amputations are completely asymptomatic, however, and do not compromise fertility assuming the contralateral adnexa are normal. Thus expectant management is appropriate for small (less than 4 cm), asymptomatic simple cysts and even suspected auto-amputated adnexa in an asymptomatic patient. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.
Fermi-Pasta-Ulam auto recurrence in the description of the electrical activity of the heart.
Novopashin, M A; Shmid, A V; Berezin, A A
2017-04-01
The authors proposed and mathematically described model of a new type of the Fermi-Pasta-Ulam recurrence (the FPU auto recurrence) and hypothesized an adequate description of the heart's electrical dynamics within the observed phenomenon. The dynamics of the FPU auto recurrence making appropriate electrical dynamics of the normal functioning of the heart in the form of an electrocardiogram (ECG) was obtained by a computer model study. The model solutions in the form of the FPU auto recurrence - ECG Fourier spectrum were evaluated for resistance to external disturbances in the form of random effects, as well as periodic perturbation at a frequency close to the heart beating rate of about 1Hz. In addition, in order to simulate the dynamics of myocardial infarction model, studied the effect of the surface area of the myocardium on the stability and shape of the auto recurrence - ECG spectrum. It has been found that the intense external disturbing periodic impacts at a frequency of about 1Hz lead to a sharp disturbance spectrum shape FPU auto recurrence - ECG structure. In addition, the decrease in the surface of the myocardium by 50% in the model led to the destruction of structures of the auto recurrence - ECG, which corresponds to the state of atrial myocardium. Research models have revealed a hypothetical basis of coronary heart disease in the form of increasing the energy of high-frequency harmonics spectrum of the auto recurrence by reducing the energy of low-frequency harmonic spectrum of the auto recurrence, which ultimately leads to a sharp decrease in myocardial contractility. In order to test the hypothesis has been studied more than 20,000 ECGs both healthy people and patients with cardiovascular disease. As a result of these studies, it was found that the dynamics of the electrical activity of normal functioning of the heart can be interpreted by the display of the detected by authors the FPU auto recurrence, and coronary heart disease is a violation of the energy ratio between the low and high frequency harmonics of the FPU auto recurrence Fourier spectrum equal to the ECG spectrum. Thus, the hypothesis has been confirmed. Copyright © 2017 Elsevier Ltd. All rights reserved.
Flatabø, Ranveig; Agarwal, Akshay; Hobbs, Richard; Greve, Martin M; Holst, Bodil; Berggren, Karl K
2018-07-06
Helium ion beam lithography (HIL) is an emerging nanofabrication technique. It benefits from a reduced interaction volume compared to that of an electron beam of similar energy, and hence reduced long-range scattering (proximity effect), higher resist sensitivity and potentially higher resolution. Furthermore, the small angular spread of the helium ion beam gives rise to a large depth of field. This should enable patterning on tilted and curved surfaces without the need of any additional adjustments, such as laser-auto focus. So far, most work on HIL has been focused on exploiting the reduced proximity effect to reach single-digit nanometer resolution, and has thus been concentrated on single-pixel exposures over small areas. Here we explore two new areas of application. Firstly, we investigate the proximity effect in large-area exposures and demonstrate HIL's capabilities in fabricating precise high-density gratings on large planar surfaces (100 μm × 100 μm, with pitch down to 35 nm) using an area dose for exposure. Secondly, we exploit the large depth of field by making the first HIL patterns on tilted surfaces (sample stage tilted 45°). We demonstrate a depth of field greater than 100 μm for a resolution of about 20 nm.
Doshi, T; Wilson, C; Paterson, C; Lamb, C; James, A; MacKenzie, K; Soraghan, J; Petropoulakis, L; Di Caterina, G; Grose, D
2017-01-01
To carry out statistical validation of a newly developed magnetic resonance imaging (MRI) auto-contouring software tool for gross tumour volume (GTV) delineation in head and neck tumours to assist in radiotherapy planning. Axial MRI baseline scans were obtained for 10 oropharyngeal and laryngeal cancer patients. GTV was present on 102 axial slices and auto-contoured using the modified fuzzy c-means clustering integrated with the level set method (FCLSM). Peer-reviewed (C-gold) manual contours were used as the reference standard to validate auto-contoured GTVs (C-auto) and mean manual contours (C-manual) from two expert clinicians (C1 and C2). Multiple geometric metrics, including the Dice similarity coefficient (DSC), were used for quantitative validation. A DSC≥0.7 was deemed acceptable. Inter- and intra-variabilities among the manual contours were also validated. The two-dimensional contours were then reconstructed in three dimensions for GTV volume calculation, comparison and three-dimensional visualisation. The mean DSC between C-gold and C-auto was 0.79. The mean DSC between C-gold and C-manual was 0.79 and that between C1 and C2 was 0.80. The average time for GTV auto-contouring per patient was 8 min (range 6-13 min; mean 45 s per axial slice) compared with 15 min (range 6-23 min; mean 88 s per axial slice) for C1. The average volume concordance between C-gold and C-auto volumes was 86.51% compared with 74.16% between C-gold and C-manual. The average volume concordance between C1 and C2 volumes was 86.82%. This newly designed MRI-based auto-contouring software tool shows initial acceptable results in GTV delineation of oropharyngeal and laryngeal tumours using FCLSM. This auto-contouring software tool may help reduce inter- and intra-variability and can assist clinical oncologists with time-consuming, complex radiotherapy planning. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Image registration with auto-mapped control volumes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schreibmann, Eduard; Xing Lei
2006-04-15
Many image registration algorithms rely on the use of homologous control points on the two input image sets to be registered. In reality, the interactive identification of the control points on both images is tedious, difficult, and often a source of error. We propose a two-step algorithm to automatically identify homologous regions that are used as a priori information during the image registration procedure. First, a number of small control volumes having distinct anatomical features are identified on the model image in a somewhat arbitrary fashion. Instead of attempting to find their correspondences in the reference image through user interaction,more » in the proposed method, each of the control regions is mapped to the corresponding part of the reference image by using an automated image registration algorithm. A normalized cross-correlation (NCC) function or mutual information was used as the auto-mapping metric and a limited memory Broyden-Fletcher-Goldfarb-Shanno algorithm (L-BFGS) was employed to optimize the function to find the optimal mapping. For rigid registration, the transformation parameters of the system are obtained by averaging that derived from the individual control volumes. In our deformable calculation, the mapped control volumes are treated as the nodes or control points with known positions on the two images. If the number of control volumes is not enough to cover the whole image to be registered, additional nodes are placed on the model image and then located on the reference image in a manner similar to the conventional BSpline deformable calculation. For deformable registration, the established correspondence by the auto-mapped control volumes provides valuable guidance for the registration calculation and greatly reduces the dimensionality of the problem. The performance of the two-step registrations was applied to three rigid registration cases (two PET-CT registrations and a brain MRI-CT registration) and one deformable registration of inhale and exhale phases of a lung 4D CT. Algorithm convergence was confirmed by starting the registration calculations from a large number of initial transformation parameters. An accuracy of {approx}2 mm was achieved for both deformable and rigid registration. The proposed image registration method greatly reduces the complexity involved in the determination of homologous control points and allows us to minimize the subjectivity and uncertainty associated with the current manual interactive approach. Patient studies have indicated that the two-step registration technique is fast, reliable, and provides a valuable tool to facilitate both rigid and nonrigid image registrations.« less
Czerw, T; Labopin, M; Gorin, N-C; Giebel, S; Blaise, D; Dumas, P-Y; Foa, R; Attal, M; Schaap, N; Michallet, M; Bonmati, C; Veelken, H; Mohty, M
2014-07-01
Application of G-CSF in AML is controversial as leukemic blasts may express receptors interacting with the cytokine, which may stimulate leukemia growth. We retrospectively analyzed the impact of G-CSF use to accelerate neutrophil recovery after auto-SCT on outcome. Adults with AML in first CR autografted between 1994 and 2010 were included. Nine hundred and seventy two patients were treated with G-CSF after auto-SCT whereas 1121 were not. BM and PB were used as a source of stem cells in 454 (22%) and 1639 (78%) cases, respectively. The incidence of relapse at 5 years in the BM-auto-SCT group was 38% for patients receiving post-transplant G-CSF and 43% for those not treated with G-CSF, P=0.46. In the PB-auto-SCT cohort, respective probabilities were 48% and 49%, P=0.49. No impact of the use of G-CSF could be demonstrated with respect to the probability of leukemia-free survival: in the BM-auto-SCT group, 51% for G-CSF(+) and 48% for G-CSF(-), P=0.73; in PB-auto-SCT group, 42% for G-CSF(+) and 43% for G-CSF(-), P=0.83. Although G-CSF administration significantly shortened the neutropenic phase, no beneficial effect was observed with regard to non-relapse mortality. In patients with AML, the use of G-CSF after auto-SCT is not associated with increased risk of relapse irrespective of the source of stem cells used.
A comparison of the autonomy over tobacco scale and the Fagerström test for nicotine dependence.
Difranza, Joseph R; Savageau, Judith A; Wellman, Robert J
2012-07-01
The autonomy over tobacco scale (AUTOS) is a 12-item theory-based instrument used to measure tobacco dependence in smokers. It provides separate measures of three factors that make smoking cessation more difficult: withdrawal symptoms, psychological dependence, and cue-induced urges to use tobacco. We compared the internal reliability and concurrent validity of the AUTOS to those of the Fagerström test for nicotine dependence (FTND). Adult current smokers (n=422; 62% female; 86.8% white; mean age 33.3 years, SD=13.7; 57% daily smokers) completed an anonymous web-based survey that included the AUTOS, the FTND and 11 smoking-related behavioral measures. Cronbach's α was .94 for the AUTOS and α>.75 for each of the 3 subscales; α=.73 for the FTND. The AUTOS and its subscales correlated with all measures of concurrent validity (r=.70 between AUTOS & FTND). The AUTOS correlated better than the FTND with the Hooked on Nicotine Checklist, the longest period of abstinence, latency to wanting, percentage of time a person smokes because of momentary need, pleasure from smoking, days smoked per month, and concern about deprivation. The measures showed similar correlations with the latencies to craving and needing. The FTND correlated better with the duration of smoking and cigarettes smoked per day. Based on these results and those from prior studies, we conclude that the AUTOS offers researchers a valid and highly reliable, theory-based measure that is more versatile in its applications than the FTND. Copyright © 2012 Elsevier Ltd. All rights reserved.
OpenSQUID: A Flexible Open-Source Software Framework for the Control of SQUID Electronics
Jaeckel, Felix T.; Lafler, Randy J.; Boyd, S. T. P.
2013-02-06
We report commercially available computer-controlled SQUID electronics are usually delivered with software providing a basic user interface for adjustment of SQUID tuning parameters, such as bias current, flux offset, and feedback loop settings. However, in a research context it would often be useful to be able to modify this code and/or to have full control over all these parameters from researcher-written software. In the case of the STAR Cryoelectronics PCI/PFL family of SQUID control electronics, the supplied software contains modules for automatic tuning and noise characterization, but does not provide an interface for user code. On the other hand, themore » Magnicon SQUIDViewer software package includes a public application programming interface (API), but lacks auto-tuning and noise characterization features. To overcome these and other limitations, we are developing an "open-source" framework for controlling SQUID electronics which should provide maximal interoperability with user software, a unified user interface for electronics from different manufacturers, and a flexible platform for the rapid development of customized SQUID auto-tuning and other advanced features. Finally, we have completed a first implementation for the STAR Cryoelectronics hardware and have made the source code for this ongoing project available to the research community on SourceForge (http://opensquid.sourceforge.net) under the GNU public license.« less
46 CFR 109.585 - Use of auto pilot.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Use of auto pilot. 109.585 Section 109.585 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.585 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
46 CFR 109.585 - Use of auto pilot.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Use of auto pilot. 109.585 Section 109.585 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.585 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
46 CFR 109.585 - Use of auto pilot.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Use of auto pilot. 109.585 Section 109.585 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.585 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
46 CFR 109.585 - Use of auto pilot.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Use of auto pilot. 109.585 Section 109.585 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.585 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
46 CFR 109.585 - Use of auto pilot.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Use of auto pilot. 109.585 Section 109.585 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.585 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...
16 CFR 640.6 - Rules of construction.
Code of Federal Regulations, 2011 CFR
2011-01-01
... credit to finance the purchase of an automobile. If the auto dealer is the person to whom the loan obligation is initially payable, such as where the auto dealer is the original creditor under a retail installment sales contract, the auto dealer must provide the risk-based pricing notice to the consumer (or...
16 CFR 640.6 - Rules of construction.
Code of Federal Regulations, 2014 CFR
2014-01-01
... credit to finance the purchase of an automobile. If the auto dealer is the person to whom the loan obligation is initially payable, such as where the auto dealer is the original creditor under a retail installment sales contract, the auto dealer must provide the risk-based pricing notice to the consumer (or...
46 CFR 122.360 - Use of auto pilot.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Use of auto pilot. 122.360 Section 122.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... Requirements § 122.360 Use of auto pilot. Whenever an automatic pilot is used the master shall ensure that: (a...
46 CFR 122.360 - Use of auto pilot.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Use of auto pilot. 122.360 Section 122.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... Requirements § 122.360 Use of auto pilot. Whenever an automatic pilot is used the master shall ensure that: (a...
16 CFR 640.6 - Rules of construction.
Code of Federal Regulations, 2013 CFR
2013-01-01
... credit to finance the purchase of an automobile. If the auto dealer is the person to whom the loan obligation is initially payable, such as where the auto dealer is the original creditor under a retail installment sales contract, the auto dealer must provide the risk-based pricing notice to the consumer (or...
46 CFR 122.360 - Use of auto pilot.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Use of auto pilot. 122.360 Section 122.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... Requirements § 122.360 Use of auto pilot. Whenever an automatic pilot is used the master shall ensure that: (a...
16 CFR 640.6 - Rules of construction.
Code of Federal Regulations, 2012 CFR
2012-01-01
... credit to finance the purchase of an automobile. If the auto dealer is the person to whom the loan obligation is initially payable, such as where the auto dealer is the original creditor under a retail installment sales contract, the auto dealer must provide the risk-based pricing notice to the consumer (or...
Cool-and Unusual-CAD Applications
ERIC Educational Resources Information Center
Calhoun, Ken
2004-01-01
This article describes several very useful applications of AutoCAD that may lie outside the normal scope of application. AutoCAD commands used in this article are based on AutoCAD 2000I. The author and his students used a Hewlett Packard 750C DesignJet plotter for plotting. (Contains 5 figures and 5 photos.)
46 CFR 122.360 - Use of auto pilot.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Use of auto pilot. 122.360 Section 122.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... Requirements § 122.360 Use of auto pilot. Whenever an automatic pilot is used the master shall ensure that: (a...