Evaluation of mouse red blood cell and platelet counting with an automated hematology analyzer.
Fukuda, Teruko; Asou, Eri; Nogi, Kimiko; Goto, Kazuo
2017-10-07
An evaluation of mouse red blood cell (RBC) and platelet (PLT) counting with an automated hematology analyzer was performed with three strains of mice, C57BL/6 (B6), BALB/c (BALB) and DBA/2 (D2). There were no significant differences in RBC and PLT counts between manual and automated optical methods in any of the samples, except for D2 mice. For D2, RBC counts obtained using the manual method were significantly lower than those obtained using the automated optical method (P<0.05), and PLT counts obtained using the manual method were higher than those obtained using the automated optical method (P<0.05). An automated hematology analyzer can be used for RBC and PLT counting; however, an appropriate method should be selected when D2 mice samples are used.
Verification and quality control of routine hematology analyzers.
Vis, J Y; Huisman, A
2016-05-01
Verification of hematology analyzers (automated blood cell counters) is mandatory before new hematology analyzers may be used in routine clinical care. The verification process consists of several items which comprise among others: precision, accuracy, comparability, carryover, background and linearity throughout the expected range of results. Yet, which standard should be met or which verification limit be used is at the discretion of the laboratory specialist. This paper offers practical guidance on verification and quality control of automated hematology analyzers and provides an expert opinion on the performance standard that should be met by the contemporary generation of hematology analyzers. Therefore (i) the state-of-the-art performance of hematology analyzers for complete blood count parameters is summarized, (ii) considerations, challenges, and pitfalls concerning the development of a verification plan are discussed, (iii) guidance is given regarding the establishment of reference intervals, and (iv) different methods on quality control of hematology analyzers are reviewed. © 2016 John Wiley & Sons Ltd.
Ciepiela, Olga; Kotuła, Iwona; Kierat, Szymon; Sieczkowska, Sandra; Podsiadłowska, Anna; Jenczelewska, Anna; Księżarczyk, Karolina; Demkow, Urszula
2016-11-01
Modern automated laboratory hematology analyzers allow the measurement of over 30 different hematological parameters useful in the diagnostic and clinical interpretation of patient symptoms. They use different methods to measure the same parameters. Thus, a comparison of complete blood count made by Mindray BC-6800, Sysmex XN-2000 and Beckman Coulter LH750 was performed. A comparison of results obtained by automated analysis of 807 anticoagulated blood samples from children and 125 manual microscopic differentiations were performed. This comparative study included white blood cell count, red blood cell count, and erythrocyte indices, as well as platelet count. The present study showed a poor level of agreement between white blood cell enumeration and differentiation of the three automated hematology analyzers under comparison. A very good agreement was found when comparing manual blood smear and automated granulocytes, monocytes, and lymphocytes differentiation. Red blood cell evaluation showed better agreement than white blood cells between the studied analyzers. To conclude, studied instruments did not ensure satisfactory interchangeability and did not facilitate a substitution of one analyzer by another. © 2016 Wiley Periodicals, Inc.
21 CFR 864.5680 - Automated heparin analyzer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Automated heparin analyzer. 864.5680 Section 864.5680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
21 CFR 864.5680 - Automated heparin analyzer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Automated heparin analyzer. 864.5680 Section 864.5680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
21 CFR 864.5680 - Automated heparin analyzer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated heparin analyzer. 864.5680 Section 864.5680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
21 CFR 864.5680 - Automated heparin analyzer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated heparin analyzer. 864.5680 Section 864.5680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
21 CFR 864.5680 - Automated heparin analyzer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Automated heparin analyzer. 864.5680 Section 864.5680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
Evaluation of Mindray BC-3600 hematology analyzer in a university hospital.
Shu, G; Lu, H; Du, H; Shi, J; Wu, G
2013-02-01
The BC-3600 Auto Hematology Analyzer (hereinafter call BC-3600) is a quantitative, automated hematology analyzer and leukocyte differential counter for In Vitro Diagnostic Use in clinical laboratories. The analyzer was evaluated and compared with the Mindray BC-3200 3-part differential (BC-3200) and Sysmex XE-2100 5-part differential (XE-2100) Hematology Analyzer in the hematology laboratory of a university hospital. The BC-3600 was evaluated according to guidelines published by Clinical and Laboratory Standards Institute (CLSI), the International Committee for Standardization in Hematology (ICSH), and Department of Food and Drug Administration (FDA). There were no background, minimal carryover (<0.5%), and excellent linearity for white blood cell (WBC), hemoglobin (Hb) level, red blood cell (RBC), and platelet (PLT) counts (r > 0.999). Precision was good at all levels for the routine cell blood count (CBC) parameters: CV% being ≤2.0, except for platelet count (PLT) at the low level with CV% of ≤5.0% and WBC at the low level with CV% of <3.0%. Correlation between the BC-3600 and BC-3200, XE-2100 were excellent (r > 0.99) for all major CBC parameters. It is concluded that the overall performance of the BC-3600 is excellent and compares well with that of BC-3200 and XE-2100. © 2012 Blackwell Publishing Ltd.
21 CFR 864.9285 - Automated cell-washing centrifuge for immuno-hematology.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated cell-washing centrifuge for immuno... Establishments That Manufacture Blood and Blood Products § 864.9285 Automated cell-washing centrifuge for immuno-hematology. (a) Identification. An automated cell-washing centrifuge for immuno-hematology is a device used...
21 CFR 864.9285 - Automated cell-washing centrifuge for immuno-hematology.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated cell-washing centrifuge for immuno... Establishments That Manufacture Blood and Blood Products § 864.9285 Automated cell-washing centrifuge for immuno-hematology. (a) Identification. An automated cell-washing centrifuge for immuno-hematology is a device used...
21 CFR 864.9285 - Automated cell-washing centrifuge for immuno-hematology.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Automated cell-washing centrifuge for immuno... Establishments That Manufacture Blood and Blood Products § 864.9285 Automated cell-washing centrifuge for immuno-hematology. (a) Identification. An automated cell-washing centrifuge for immuno-hematology is a device used...
21 CFR 864.9285 - Automated cell-washing centrifuge for immuno-hematology.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Automated cell-washing centrifuge for immuno... Establishments That Manufacture Blood and Blood Products § 864.9285 Automated cell-washing centrifuge for immuno-hematology. (a) Identification. An automated cell-washing centrifuge for immuno-hematology is a device used...
21 CFR 864.9285 - Automated cell-washing centrifuge for immuno-hematology.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Automated cell-washing centrifuge for immuno... Establishments That Manufacture Blood and Blood Products § 864.9285 Automated cell-washing centrifuge for immuno-hematology. (a) Identification. An automated cell-washing centrifuge for immuno-hematology is a device used...
Tabe, Yoko; Takemura, Hiroyuki; Kimura, Konobu; Takahashi, Toshihiro; Yang, Haeun; Tsuchiya, Koji; Konishi, Aya; Uchihashi, Kinya; Horii, Takashi; Ohsaka, Akimichi
2018-01-01
Morphological microscopic examinations of nucleated cells in body fluid (BF) samples are performed to screen malignancy. However, the morphological differentiation is time-consuming and labor-intensive. This study aimed to develop a new flowcytometry-based gating analysis mode “XN-BF gating algorithm” to detect malignant cells using an automated hematology analyzer, Sysmex XN-1000. XN-BF mode was equipped with WDF white blood cell (WBC) differential channel. We added two algorithms to the WDF channel: Rule 1 detects larger and clumped cell signals compared to the leukocytes, targeting the clustered malignant cells; Rule 2 detects middle sized mononuclear cells containing less granules than neutrophils with similar fluorescence signal to monocytes, targeting hematological malignant cells and solid tumor cells. BF samples that meet, at least, one rule were detected as malignant. To evaluate this novel gating algorithm, 92 various BF samples were collected. Manual microscopic differentiation with the May-Grunwald Giemsa stain and WBC count with hemocytometer were also performed. The performance of these three methods were evaluated by comparing with the cytological diagnosis. The XN-BF gating algorithm achieved sensitivity of 63.0% and specificity of 87.8% with 68.0% for positive predictive value and 85.1% for negative predictive value in detecting malignant-cell positive samples. Manual microscopic WBC differentiation and WBC count demonstrated 70.4% and 66.7% of sensitivities, and 96.9% and 92.3% of specificities, respectively. The XN-BF gating algorithm can be a feasible tool in hematology laboratories for prompt screening of malignant cells in various BF samples. PMID:29425230
Ai, Tomohiko; Tabe, Yoko; Takemura, Hiroyuki; Kimura, Konobu; Takahashi, Toshihiro; Yang, Haeun; Tsuchiya, Koji; Konishi, Aya; Uchihashi, Kinya; Horii, Takashi; Ohsaka, Akimichi
2018-01-01
Morphological microscopic examinations of nucleated cells in body fluid (BF) samples are performed to screen malignancy. However, the morphological differentiation is time-consuming and labor-intensive. This study aimed to develop a new flowcytometry-based gating analysis mode "XN-BF gating algorithm" to detect malignant cells using an automated hematology analyzer, Sysmex XN-1000. XN-BF mode was equipped with WDF white blood cell (WBC) differential channel. We added two algorithms to the WDF channel: Rule 1 detects larger and clumped cell signals compared to the leukocytes, targeting the clustered malignant cells; Rule 2 detects middle sized mononuclear cells containing less granules than neutrophils with similar fluorescence signal to monocytes, targeting hematological malignant cells and solid tumor cells. BF samples that meet, at least, one rule were detected as malignant. To evaluate this novel gating algorithm, 92 various BF samples were collected. Manual microscopic differentiation with the May-Grunwald Giemsa stain and WBC count with hemocytometer were also performed. The performance of these three methods were evaluated by comparing with the cytological diagnosis. The XN-BF gating algorithm achieved sensitivity of 63.0% and specificity of 87.8% with 68.0% for positive predictive value and 85.1% for negative predictive value in detecting malignant-cell positive samples. Manual microscopic WBC differentiation and WBC count demonstrated 70.4% and 66.7% of sensitivities, and 96.9% and 92.3% of specificities, respectively. The XN-BF gating algorithm can be a feasible tool in hematology laboratories for prompt screening of malignant cells in various BF samples.
Performance evaluation of BC-3200 hematology analyzer in a university hospital.
Peng, L; Bai, L; Nie, L; Wu, Z; Yan, C
2008-06-01
The BC-3200 automated hematology analyzer was evaluated and compared with the Beckman-Coulter AcT (Ac.T diff 2) 3-part differential hematology analyzer. The BC-3200 was evaluated according to guidelines published by the International Committee for Standardization in Hematology (ICSH), Clinical and Laboratory Standards Institute (CLSI), and Department of Food and Drug Administration (FDA). The results demonstrated no background, minimal carryover (<0.5%), and excellent linearity for hemoglobin (Hb) level, white blood cell (WBC), red blood cell (RBC), and platelet (PLT) counts (>0.998). Precision was generally acceptable for all complete blood count (CBC) parameters; coefficients of variation (CVs) were within the manufacturer's claims and CVs of CBC parameters, including WBC, RBC and PLT counts, Hb and mean corpuscular volume, were <6%. Correlation between the BC-3200 and Ac.T diff 2 was excellent (r > 0.98) for all major CBC parameters (WBC, RBC, and PLT counts and Hb). We conclude that the overall performance of the BC-3200 is excellent and compares well with that of the Coulter Ac.T diff 2.
Gupta, Monica; Chauhan, Kriti; Singhvi, Tanvi; Kumari, Manisha; Grover, Rajesh Kumar
2018-01-21
Automated cell counters have become more and more sophisticated with passing years. The numerical and graphic data both provide useful clues for suspecting a diagnosis especially when the workload is very high. We present our experience of useful information provided by graphic displays of an automated cell counter in hematological malignancies in a cancer hospital where a large number of complete blood count (CBC) requests are received either before or during chemotherapy. This study was conducted to assess the usefulness of hematology cell counter, viz. WBC-Diff (WBC differential), WBC/BASO (WBC basophil) and IMI (immature myeloid information) channel scatter plots, and the flaggings generated in various hematological malignancies. The graphic displays have been compiled over a period of 1 year (October 2015-September 2016) from blood samples of various solid and hematological malignancies (approximately 400 per day) received for routine CBC in the laboratory. Approximately 50 000 scattergrams have been analyzed during the study period. The findings were confirmed by peripheral blood smear examination. The scattergram analysis on XE-2100 is very sensitive as well as specific for diagnosing acute leukemia, viz. acute myeloid leukemia, acute lymphoblastic leukemia; chronic myeloproliferative disorders, viz. chronic myeloid leukemia; and chronic lymphoproliferative disorder especially chronic lymphocytic leukemia. It is suggested that the laboratories using the hematology analyzers be aware of graphic display patterns in addition to flaggings generated which provide additional information and give clue toward the diagnosis even before peripheral smear examination. © 2018 Wiley Periodicals, Inc.
Tanada, H; Ikemoto, T; Masutani, R; Tanaka, H; Takubo, T
2014-02-01
In this study, we evaluated the performance of the ADVIA 120 hematology system for cerebrospinal fluid (CSF) assay. Cell counts and leukocyte differentials in CSF were examined with the ADVIA 120 hematology system, while simultaneously confirming an effective hemolysis agent for automated CSF cell counts. The detection limits of both white blood cell (WBC) counts and red blood cell (RBC) counts on the measurement of CSF cell counts by the ADVIA 120 hematology system were superior at 2 cells/μL (10(-6) L). The WBC count was linear up to 9.850 cells/μL, and the RBC count was linear up to approximately 20 000 cells/μL. The intrarun reproducibility indicated good precision. The leukocyte differential of CSF cells, performed by the ADVIA120 hematology system, showed good correlation with the microscopic procedure. The VersaLyse hemolysis solution efficiently lysed the samples without interfering with cell counts and leukocyte differential, even in a sample that included approximately 50 000/μL RBC. These data show the ADVIA 120 hematology system correctly measured the WBC count and leukocyte differential in CSF. The VersaLyse hemolysis solution is considered to be optimal for hemolysis treatment of CSF when measuring cell counts and differentials by the ADVIA 120 hematology system. © 2013 John Wiley & Sons Ltd.
Performance evaluation of Samsung LABGEO(HC10) Hematology Analyzer.
Park, Il Joong; Ahn, Sunhyun; Kim, Young In; Kang, Seon Joo; Cho, Sung Ran
2014-08-01
The Samsung LABGEO(HC10) Hematology Analyzer (LABGEO(HC10)) is a recently developed automated hematology analyzer that uses impedance technologies. The analyzer provides 18 parameters including 3-part differential at a maximum rate of 80 samples per hour. To evaluate the performance of the LABGEO(HC10). We evaluated precision, linearity, carryover, and relationship for complete blood cell count parameters between the LABGEO(HC10) and the LH780 (Beckman Coulter Inc) in a university hospital in Korea according to the Clinical and Laboratory Standards Institute guidelines. Sample stability and differences due to the anticoagulant used (K₂EDTA versus K₃EDTA) were also evaluated. The LABGEO(HC10) showed linearity over a wide range and minimal carryover (<1%) for white blood cell, hemoglobin, red blood cell, and platelet parameters. Correlation between the LABGEO(HC10) and the LH780 was good for all complete blood cell count parameters (R > 0.92) except for mean corpuscular hemoglobin concentration. The bias estimated was acceptable for all parameters investigated except for monocyte count. Most parameters were stable until 24 hours both at room temperature and at 4°C. The difference by anticoagulant type was statistically insignificant for all parameters except for a few red cell parameters. The accurate results achievable and simplicity of operation make the unit recommendable for small to medium-sized laboratories.
Kim, Sue Jung; Kim, Yoonjung; Shin, Saeam; Song, Jaewoo; Choi, Jong Rak
2012-11-01
In the clinical laboratory, it is important both to reduce the number of peripheral blood slide reviews to save time and money and to avoid reporting false results. To determine differences in the slide review rates of 3 widely used automated hematologic analyzers, the Unicel DxH 800 (Beckman Coulter Inc, Fullerton, California), ADVIA 2120i (Siemens Diagnostics, Tarrytown, New York), and XE 2100 (Sysmex, Kobe, Japan), using International Consensus Group for Hematology Review guidelines. A total of 1485 samples were tested, and 300 were manually reviewed. Slide review rates, sensitivity, specificity, and false-positive and false-negative rates were estimated using consensus group rules and compared using χ(2) tests, Fisher exact tests, or generalized estimating equations. Unicel DxH 800, ADVIA 2120i, and XE 2100 showed 22.8%, 20.2%, and 28.6% slide review rates; 14.3%, 14.3%, and 9.7% false-negative rates; and 13.7, 11.3%, and 17.3% false-positive rates, respectively. All analyzers showed significantly higher false-negative rates than that of the consensus group (2.9%). False-negative rates were higher than the recommended levels. Among 3 automated hematologic analyzers, XE 2100 showed the highest rate of slide review. Because the present study clearly shows that the slide review rates have distinct characteristics among the studied analyzers, each individual laboratory should consider selecting the most appropriate analyzer according to clinical characteristics. Analyzers with high sensitivity may be advantageous in outpatient settings for screening patients, whereas analyzers with high specificity may be beneficial in inpatient settings for efficient patient care.
Bruegel, Mathias; Nagel, Dorothea; Funk, Manuela; Fuhrmann, Petra; Zander, Johannes; Teupser, Daniel
2015-06-01
Various types of automated hematology analyzers are used in clinical laboratories. Here, we performed a side-by-side comparison of five current top of the range routine hematology analyzers in the setting of a university hospital central laboratory. Complete blood counts (CBC), differentials, reticulocyte and nucleated red blood cell (NRBC) counts of 349 patient samples, randomly taken out of routine diagnostics, were analyzed with Cell-Dyn Sapphire (Abbott), DxH 800 (Beckman Coulter), Advia 2120i (Siemens), XE-5000 and XN-2000 (Sysmex). Inter-instrument comparison of CBCs including reticulocyte and NRBC counts and investigation of flagging quality in relation to microscopy were performed with the complete set of samples. Inter-instrument comparison of five-part differential was performed using samples without atypical cells in blood smear (n=292). Automated five-part differentials and NRBCs were additionally compared with microscopy. The five analyzers showed a good concordance for basic blood count parameters. Correlations between instruments were less well for reticulocyte counts, NRBCs, and differentials. The poorest concordance for NRBCs with microscopy was observed for Advia 2120i (Kendall's τb=0.37). The highest flagging sensitivity for blasts was observed for XN-2000 (97% compared to 65%-76% for other analyzers), whereas overall specificity was comparable between different instruments. To the best of our knowledge, this is the most comprehensive side-by-side comparison of five current top of the range routine hematology analyzers. Variable analyzer quality and parameter specific limitations must be considered in defining laboratory algorithms in clinical practice.
Da Rin, G; Vidali, M; Balboni, F; Benegiamo, A; Borin, M; Ciardelli, M L; Dima, F; Di Fabio, A; Fanelli, A; Fiorini, F; Francione, S; Germagnoli, L; Gioia, M; Lari, T; Lorubbio, M; Marini, A; Papa, A; Seghezzi, M; Solarino, L; Pipitone, S; Tilocca, E; Buoro, S
2017-12-01
Recent automated hematology analyzers (HAs) can identify and report nucleated red blood cells (NRBC) count as a separate population out of white blood cells (WBC). The aim of this study was to investigate the analytical performances of NRBC enumeration on five top of the range HAs. We evaluated the within-run and between-day precision, limit of blank (LoB), limit of detection (LoD), and limit of quantitation (LoQ) of XE-2100 and XN-module (Sysmex), ADVIA 2120i (Siemens), BC-6800 (Mindray), and UniCel DxH 800 (Beckman Coulter). Automated NRBC counts were also compared with optical microscopy (OM). The limits of detection for NRBC of the BC-6800, XN-module, XE-2100, UniCel DxH 800, and ADVIA 2120i are 0.035×10 9 /L, 0.019×10 9 /L, 0.067×10 9 /L, 0.038×10 9 /L, and 0.167×10 9 /L, respectively. Our data indicated excellent performance in terms of precision. The agreement with OM was excellent for BC-6800, XN-module, and XE-2100 (Bias 0.023, 0.019, and 0.033×10 9 /L, respectively). ADVIA 2120i displayed a significant constant error and UniCel DxH 800 both proportional and small constant error. Regards to NRBC counting, the performances shown by BC-6800, XN-module, and XE-2100 are excellent also a low count, ADVIA 2120i and UniCel DxH 800 need to be improved. © 2017 John Wiley & Sons Ltd.
Becker, P-H; Fenneteau, O; Da Costa, L
2016-02-01
The automated XN-1000 hematology analyzer enables to perform a blood cell count and a leukocyte differential. When abnormal cells were detected, a flag was generated by the analyzer and a manual microscopic examination of the corresponding blood film was performed. We compared the white blood cell differentials provided by the automated hematology analyzer XN-1000 in a pediatric population (n = 765) with those obtained through microscopic examination by cytologists and those obtained using a previous version of this analyzer, the XE-2100. Leukocytes count as well as flags sensitivity and specificity was analyzed. The leukocytes count provided by the analyzer is in good accordance with the differential obtained by manual count in children older than 3 months. The sensitivity for blast detection is 99% and the detection of reactive cells is 63%. The flag specificity remains low (<35%) for blood samples collected from infants between 8 days and 2 years of age, but increases up to 67% thereafter. The results obtained with the XN-1000 analyzer show an improvement in comparison with those obtained with the XE-2100 analyzer. The automated WBC differential provided by the XN-1000 analyzer in the pediatric setting is accurate, but a meticulous microscopic examination of blood smears remains necessary for infants up to 3 months of age to validate the analyzer flags. © 2015 John Wiley & Sons Ltd.
Nomura, N; Saito, K; Ikeda, M; Yuasa, S; Pastore, M; Chabert, C; Kono, E; Sakai, A; Tanaka, H; Ikemoto, T; Takubo, T
2015-08-01
We evaluated the basic performance of Microsemi CRP, an unique automated hematology analyzer which can simultaneously measure CBC including 3-part WBC differential (3-Diff) and CRP using whole blood treated with EDTA-2K anticoagulant. We found that it produced generally the acceptable results for all parameters performed (repeatability, reproducibility, linearity, interference effect, carry over, and correlation) using control materials, fresh human whole bloods, and serum samples. CBC data examined using Microsemi CRP showed the good correlation with the previous model, Micros CRP200 (r ≧ 0.9), and also those obtained using the routine analyzer, ADVIA 2120i (r ≧ 0.989). Concerning the 3-Diff, both GRA (%) and LYM (%) showed the excellent correlation coefficient between Microsemi CRP and Micros CRP200 (r ≧ 0.992) as well as ADVIA 2120i (r ≧ 0.957). MON (%) showed good correlation between Microsemi CRP and Micros CRP200 (r = 0.959), but lower correlation between Microsemi CRP and ADVIA 2120 i (r = 0.471). CRP data showed the good correlation with HITACHI7600 (r ≧ 0.997) and Micros CRP200 (r ≧ 0.997). From these findings, we concluded that Microsemi CRP seemed the convenient laboratory analyzer in the setting of point of care testing (POCT) especially at NICU or primary care unit. © 2014 John Wiley & Sons Ltd.
An evaluation of the ELT-8 hematology analyzer.
Raik, E; McPherson, J; Barton, L; Hewitt, B S; Powell, E G; Gordon, S
1982-04-01
The TMELT-8 Hematology Analyzer is a fully automated cell counter which utilizes laser light scattering and hydrodynamic focusing to provide an 8 parameter whole blood count. The instrument consists of a sample handler with ticket printer, and a data handler with visual display unit, It accepts 100 microliter samples of venous or capillary blood and prints the values for WCC, RCC, Hb, Hct, MCV, MCH, MCHC and platelet count on to a standard result card. All operational and quality control functions, including graphic display of relative cell size distribution, can be obtained from the visual display unit and can also be printed as a permanent record if required. In a limited evaluation of the ELT-8, precision, linearity, accuracy, lack of sample carry-over and user acceptance were excellent. Reproducible values were obtained for all parameters after overnight storage of samples. Reagent usage and running costs were lower than for the Coulter S and the Coulter S Plus. The ease of processing capillary samples was considered to be a major advantage. The histograms served to alert the operator to a number of abnormalities, some of which were clinically significant.
Takemura, Hiroyuki; Ai, Tomohiko; Kimura, Konobu; Nagasaka, Kaori; Takahashi, Toshihiro; Tsuchiya, Koji; Yang, Haeun; Konishi, Aya; Uchihashi, Kinya; Horii, Takashi; Tabe, Yoko; Ohsaka, Akimichi
2018-01-01
The XN series automated hematology analyzer has been equipped with a body fluid (BF) mode to count and differentiate leukocytes in BF samples including cerebrospinal fluid (CSF). However, its diagnostic accuracy is not reliable for CSF samples with low cell concentration at the border between normal and pathologic level. To overcome this limitation, a new flow cytometry-based technology, termed "high sensitive analysis (hsA) mode," has been developed. In addition, the XN series analyzer has been equipped with the automated digital cell imaging analyzer DI-60 to classify cell morphology including normal leukocytes differential and abnormal malignant cells detection. Using various BF samples, we evaluated the performance of the XN-hsA mode and DI-60 compared to manual microscopic examination. The reproducibility of the XN-hsA mode showed good results in samples with low cell densities (coefficient of variation; % CV: 7.8% for 6 cells/μL). The linearity of the XN-hsA mode was established up to 938 cells/μL. The cell number obtained using the XN-hsA mode correlated highly with the corresponding microscopic examination. Good correlation was also observed between the DI-60 analyses and manual microscopic classification for all leukocyte types, except monocytes. In conclusion, the combined use of cell counting with the XN-hsA mode and automated morphological analyses using the DI-60 mode is potentially useful for the automated analysis of BF cells.
Sharma, P; Bhargava, M; Sukhachev, D; Datta, S; Wattal, C
2014-02-01
Tropical febrile illnesses such as malaria and dengue are challenging to differentiate clinically. Automated cellular indices from hematology analyzers may afford a preliminary rapid distinction. Blood count and VCS parameters from 114 malaria patients, 105 dengue patients, and 105 febrile controls without dengue or malaria were analyzed. Statistical discriminant functions were generated, and their diagnostic performances were assessed by ROC curve analysis. Three statistical functions were generated: (i) malaria-vs.-controls factor incorporating platelet count and standard deviations of lymphocyte volume and conductivity that identified malaria with 90.4% sensitivity, 88.6% specificity; (ii) dengue-vs.-controls factor incorporating platelet count, lymphocyte percentage and standard deviation of lymphocyte conductivity that identified dengue with 81.0% sensitivity and 77.1% specificity; and (iii) febrile-controls-vs.-malaria/dengue factor incorporating mean corpuscular hemoglobin concentration, neutrophil percentage, mean lymphocyte and monocyte volumes, and standard deviation of monocyte volume that distinguished malaria and dengue from other febrile illnesses with 85.1% sensitivity and 91.4% specificity. Leukocyte abnormalities quantitated by automated analyzers successfully identified malaria and dengue and distinguished them from other fevers. These economic discriminant functions can be rapidly calculated by analyzer software programs to generate electronic flags to trigger-specific testing. They could potentially transform diagnostic approaches to tropical febrile illnesses in cost-constrained settings. © 2013 John Wiley & Sons Ltd.
Bourner, G; Dhaliwal, J; Sumner, J
2005-01-01
Gamma-Dynacare is a Canadian-based community laboratory partnership formed in the mid-1990s through the merger of 3 prominent Ontario medical diagnostic laboratories. Laboratory Corporation of America acquired an interest in the GD partnership in mid 2002. We service more than 10,000 community-based Canadian clinicians, hospital partners, and private clients with an integrated customer-focused system that includes specimen collection, transportation, and results reporting services. With more than 1,700 highly qualified medical, technical, and support staff and a network of laboratories, Gamma Dynacare aims to be at the forefront of technological innovation to better service the clinician base and ultimately deliver better patient care. We were looking for a hematology analyzer that would allow. (1) standardization throughout Ontario in our 4 largest sites and (2) better performance to effectively handle aged samples and minimize slide review. To select the best, most productive hematology analyzer for our environment, it was decided to perform a side-by-side comparison of the top hematology analyzers from Abbott (Cell-Dyn 3500), Beckman Coulter (LH 750), Bayer (Advia 120), and Sysmex (XE 2100), utilizing the same samples. CBC, differential and reticulocyte parameters were all evaluated according to CLSI (formerly NCCLS) and established hematology analyzer evaluation guidelines. We assessed each analyzer for precision, linearity, carryover, stability, differential capabilities, slide review rates, and throughput (clean bench studies). Two hundred samples were assessed for differential and morphology flagging on each analyzer using the reference 400 cell manual differential for comparison. Throughput was assessed by analyzing 700 consecutive samples representative of our workload mix. Stability studies at 24 hours showed that the Beckman Coulter LH 750 was least affected by EDTA, effect with minimal changes in the mean corpuscular volume (MCV) and hematocrit. Both
[Automated analyzer of enzyme immunoassay].
Osawa, S
1995-09-01
Automated analyzers for enzyme immunoassay can be classified by several points of view: the kind of labeled antibodies or enzymes, detection methods, the number of tests per unit time, analytical time and speed per run. In practice, it is important for us consider the several points such as detection limits, the number of tests per unit time, analytical range, and precision. Most of the automated analyzers on the market can randomly access and measure samples. I will describe the recent advance of automated analyzers reviewing their labeling antibodies and enzymes, the detection methods, the number of test per unit time and analytical time and speed per test.
Performance evaluation of the new hematology analyzer Sysmex XN-series.
Seo, J Y; Lee, S-T; Kim, S-H
2015-04-01
The Sysmex XN-series is a new automated hematology analyzer designed to improve the accuracy of cell counts and the specificity of the flagging events. The basic characteristics and the performance of new measurement channels of the XN were evaluated and compared with the Sysmex XE-2100 and the manual method. Fluorescent platelet count (PLT-F) was compared with the flow cytometric method. The low WBC mode and body fluid mode were also evaluated. For workflow analysis, 1005 samples were analyzed on both the XN and the XE-2100, and manual review rates were compared. All parameters measured by the XN correlated well with the XE-2100. PLT-F showed better correlation with the flow cytometric method (r(2) = 0.80) compared with optical platelet count (r(2) = 0.73) for platelet counts <70 × 10(9) /L. The low WBC mode reported accurate leukocyte differentials for samples with a WBC count <0.5 × 10(9) /L. Relatively good correlation was found for WBC counts between the manual method and the body fluid mode (r = 0.88). The XN made less flags than the XE-2100, while the sensitivities of both instruments were comparable. The XN provided reliable results on low cell counts, as well as reduced manual blood film reviews, while maintaining a proper level of diagnostic sensitivity. © 2014 John Wiley & Sons Ltd.
Mlinaric, Ana; Milos, Marija; Coen Herak, Désirée; Fucek, Mirjana; Rimac, Vladimira; Zadro, Renata; Rogic, Dunja
2018-02-23
The need to satisfy high-throughput demands for laboratory tests continues to be a challenge. Therefore, we aimed to automate postanalytical phase in hematology and coagulation laboratory by autovalidation of complete blood count (CBC) and routine coagulation test results (prothrombin time [PT], international normalized ratio [PT-INR], activated partial thromboplastin time [APTT], fibrinogen, antithrombin activity [AT] and thrombin time [TT]). Work efficacy and turnaround time (TAT) before and after implementation of automated solutions will be compared. Ordering panels tailored to specific patient populations were implemented. Rerun and reflex testing rules were set in the respective analyzers' software (Coulter DxH Connectivity 1601, Beckman Coulter, FL, USA; AutoAssistant, Siemens Healthcare Diagnostics, Germany), and sample status information was transferred into the laboratory information system. To evaluate if the automation improved TAT and efficacy, data from manually verified results in September and October of 2015 were compared with the corresponding period in 2016 when autovalidation was implemented. Autovalidation rates of 63% for CBC and 65% for routine coagulation test results were achieved. At the TAT of 120 min, the percentage of reported results increased substantially for all analyzed tests, being above 90% for CBC, PT, PT-INR and fibrinogen and 89% for APTT. This output was achieved with three laboratory technicians less compared with the period when the postanalytical phase was not automated. Automation allowed optimized laboratory workflow for specific patient populations, thereby ensuring standardized results reporting. Autovalidation of test results proved to be an efficient tool for improvement of laboratory work efficacy and TAT.
Cook, Andrea M; Moritz, Andreas; Freeman, Kathleen P; Bauer, Natali
2016-09-01
Scarce information exists about quality requirements and objective evaluation of performance of large veterinary bench top hematology analyzers. The study was aimed at comparing the observed total error (TEobs ) derived from meta-analysis of published method validation data to the total allowable error (TEa ) for veterinary hematology variables in small animals based on experts' opinions. Ideally, TEobs should be < TEa . An online survey was sent to veterinary experts in clinical pathology and small animal internal medicine for providing the maximal allowable deviation from a given result for each variable. Percent of TEa = (allowable median deviation/clinical threshold) * 100%. Second, TEobs for 3 laser-based bench top hematology analyzers (ADVIA 2120; Sysmex XT2000iV, and CellDyn 3500) was calculated based on method validation studies published between 2005 and 2013 (n = 4). The percent TEobs = 2 * CV (%) + bias (%). The CV was derived from published studies except for the ADVIA 2120 (internal data), and bias was estimated from the regression equation. A total of 41 veterinary experts (19 diplomates, 8 residents, 10 postgraduate students, 4 anonymous specialists) responded. The proposed range of TEa was wide, but generally ≤ 20%. The TEobs was < TEa for all variables and analyzers except for canine and feline HGB (high bias, low CV) and platelet counts (high bias, high CV). Overall, veterinary bench top analyzers fulfilled experts' requirements except for HGB due to method-related bias, and platelet counts due to known preanalytic/analytic issues. © 2016 American Society for Veterinary Clinical Pathology.
2002-01-14
The Food and Drug Administration (FDA) is reclassifying the automated differential cell counter (ADCC) from class III (premarket approval) into class II (special controls). FDA is also identifying the guidance document entitled "Class II Special Controls Guidance Document: Premarket Notifications for Automated Differential Cell Counters for Immature or Abnormal Blood Cells; Final Guidance for Industry and FDA" as the special control that the agency believes will reasonably ensure the safety and effectiveness of the device. This reclassification is being undertaken based on new information submitted in a reclassification petition from the International Society for Laboratory Hematology (ISLH), under the Federal Food, Drug, and Cosmetic Act (the act), as amended by the Safe Medical Devices Act of 1990 and the FDA Modernization Act of 1997.
Ameri, Mehrdad; Schnaars, Henry A; Sibley, John R; Honor, David J
2011-06-01
The time from sampling to analysis can be delayed when blood samples are shipped to distant reference laboratories or when analysis cannot be readily performed. The objective of this study was to evaluate the stability of hematologic analytes in blood samples from monkeys, rabbits, rats, and mice when samples were stored for up to 72 hours at 4°C. Blood samples from 30 monkeys, 15 rabbits, 20 rats, and 30 mice were collected into EDTA-containing tubes and were initially analyzed within 1 hour of collection using the ADVIA 120 analyzer. The samples were then stored at 4°C and reanalyzed at 24, 48, and 72 hours after collection. Significant (P<.0003) changes in hematologic analytes and calculations included increased HCT and MCV and decreased MCHC and cell hemoglobin concentration mean (CHCM) at 72 hours and increased MPV at 24 hours in monkeys; increased MCV at 72 hours and MPV at 48 hours and decreased monocyte count at 24 hours in rabbits; increased MCV and decreased MCHC, CHCM, and monocyte count at 24 hours in rats; increased MCV, red cell distribution width, and MPV and decreased MCHC, CHCM, and monocyte count at 24 hours in mice. Although most of the changes in the hematologic analytes in blood from monkeys, rabbits, rats, and mice when samples were stored at 4°C were analytically acceptable and clinically negligible, the best practice in measuring hematologic analytes in these animals is timely processing of blood samples, preferably within 1 hour after collection. ©2011 American Society for Veterinary Clinical Pathology.
Srivastava, A; Koul, V; Dwivedi, S N; Upadhyaya, A D; Ahuja, A; Saxena, R
2015-08-01
The aim of this study was to evaluate the performance of the newly developed handheld hemoglobinmeter (TrueHb) by comparing its performance against and an automated five-part hematology analyzer, Sysmex counter XT 1800i (Sysmex). Two hundred venous blood samples were subjected through their total hemoglobin evaluation on each device three times. The average of the three readings on each device was considered as their respective device values, that is, TrueHb values and Sysmex values. The two set of values were comparatively analyzed. The repeatability of the performance of TrueHb was also evaluated against Sysmex values. The scatter plot of TrueHb values and Sysmex values showed linear distribution with positive correlations (r = 0.99). The intraclass correlation (ICC) values between the two set of values was found to be 0.995. Regression coefficients through origin, β, was found to be 0.995, with 95% confidence intervals (CI) ranging between 0.9900 and 1.0000. The mean difference in Bland-Altman plots of TrueHb values against the Sysmex values was found to be -0.02, with limits of agreement between -0.777 and 0.732 g/dL. Statistical analysis suggested good repeatability in results of TrueHb, having a low mean CV of 2.22, against 4.44, that of Sysmex values, and 95% confidence interval of 1.99-2.44, against 3.85-5.03, that of Sysmex values. These results suggested a strong positive correlation between the two measurements devices. It is thus concluded that TrueHb is a good point-of-care testing tool for estimating hemoglobin. © 2014 John Wiley & Sons Ltd.
21 CFR 864.5850 - Automated slide spinner.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated slide spinner. 864.5850 Section 864.5850 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
21 CFR 864.5620 - Automated hemoglobin system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Automated hemoglobin system. 864.5620 Section 864.5620 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
21 CFR 864.5620 - Automated hemoglobin system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Automated hemoglobin system. 864.5620 Section 864.5620 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
21 CFR 864.5850 - Automated slide spinner.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Automated slide spinner. 864.5850 Section 864.5850 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
21 CFR 864.5850 - Automated slide spinner.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Automated slide spinner. 864.5850 Section 864.5850 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
21 CFR 864.5850 - Automated slide spinner.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated slide spinner. 864.5850 Section 864.5850 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
21 CFR 864.5850 - Automated slide spinner.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Automated slide spinner. 864.5850 Section 864.5850 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
21 CFR 864.5620 - Automated hemoglobin system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Automated hemoglobin system. 864.5620 Section 864.5620 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
ISO/IEC 17025 Sysmex R-500 hematology reticulocyte analyzer validation.
Dimopoulou, H A; Theodoridis, T; Galea, V; Christopoulou-Cokkinou, V; Spyridaki, M-H E; Georgakopoulos, C G
2007-01-01
The Sysmex R-500 (R-500) Hematology Analyzer is a bench-top system appropriate for the analysis of limited batches of blood samples. The R-500 provides percentage proportional (RET%), absolute reticulocyte (RET#), and absolute red blood cell (RBC#) counts. The system was validated at the Doping Control Laboratory of Athens, according to the International Committee for Standardization in Hematology, International Standards Organization (ISO/IEC) 17025, and World Antidoping Agency (WADA) specifications. The instrument calibration was performed according to the manufacturer and validation parameters comprised linearity, precision, uncertainty (intermediate and long-term precision), comparability, effect of drift, carryover, stability, and accuracy. The linearity and the comparability studies for RET#, RET%, and RBC# were expressed in regression factors (R2) and coefficients of correlation [r(x, y)], respectively. For the precision studies, the coefficients of variation for RET#, RET%, and RBC# were 9.49%, 9.83%, and <1.5%, respectively. For the intermediate precision studies, the coefficients of variation for RET#, RET%, and RBC# were 3.1%, 3.6%, and 0.6%, respectively. Carryover was found to be negligible. Sample stability was demonstrated at both room temperature and at 4 degrees C over a 24-hour period. Comparability studies for the R-500 were performed using a Sysmex SE-9500. The total evaluation led to the conclusion that the R-500 is an accurate and precise analyzer and because of to its relatively limited size, it can be considered a portable instrument, capable to be used in sports competition and training sites, where doping control and health tests are conducted. The analytical methodology of RET% measurement by the R-500 has been incorporated into the Doping Control Laboratory of Athens' Scope of Accreditation according to the ISO/IEC 17025 and WADA specifications.
21 CFR 864.5800 - Automated sedimentation rate device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Automated sedimentation rate device. 864.5800 Section 864.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...
21 CFR 864.5800 - Automated sedimentation rate device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Automated sedimentation rate device. 864.5800 Section 864.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...
21 CFR 864.5800 - Automated sedimentation rate device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated sedimentation rate device. 864.5800 Section 864.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...
21 CFR 864.5800 - Automated sedimentation rate device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated sedimentation rate device. 864.5800 Section 864.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...
21 CFR 864.5800 - Automated sedimentation rate device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Automated sedimentation rate device. 864.5800 Section 864.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...
Harvey, Stephen B; Krimer, Paula M; Correa, Maria T; Hanes, Martha A
2008-07-01
Plasma biochemical and hematologic values are important parameters for assessing animal health and experimental results. Although normal reference values for many rodent species have been published, there is a dearth of similar information for the genus Microtus. In addition, most studies use a mean and standard deviation to establish reference intervals, but doing so is not the recommendation of the Clinical and Laboratory Standards Institute (formerly the National Committee on Clinical Laboratory Standards) or the International Federation of Clinical Chemistry and Laboratory Medicine. The purpose of this study was to establish normal reference parameters for plasma biochemistry and hematology in mature pine voles (Microtus pinetorum) by using the nonparametric rank percentile method as recommended by the 2 laboratory medicine organizations mentioned. Samples of cardiac blood from a closed colony of pine voles were collected at euthanasia and evaluated under rodent settings on 2 automated hematology analyzers from 2 different manufacturers and on the same type of automated biochemistry analyzer. There were no sex-associated clinically significant differences between the sexes; younger animals had a lower hematocrit, higher mean corpuscular volume, and lower mean corpuscular hemoglobin concentration than did older animals. Only platelet counts differed when comparing hematologic values from different analyzers. Relative to rats and mice, pine voles have a lower mean corpuscular volume and higher red blood cell count, higher blood urea nitrogen, much higher alanine aminotransferase, and lower glucose and phosphorous concentrations. Hematology and plasma biochemical results obtained in this study are considered representative for healthy adult laboratory pine voles under similar environmental conditions.
Harvey, Stephen B; Krimer, Paula M; Correa, Maria T; Hanes, Martha A
2008-01-01
Plasma biochemical and hematologic values are important parameters for assessing animal health and experimental results. Although normal reference values for many rodent species have been published, there is a dearth of similar information for the genus Microtus. In addition, most studies use a mean and standard deviation to establish reference intervals, but doing so is not the recommendation of the Clinical and Laboratory Standards Institute (formerly the National Committee on Clinical Laboratory Standards) or the International Federation of Clinical Chemistry and Laboratory Medicine. The purpose of this study was to establish normal reference parameters for plasma biochemistry and hematology in mature pine voles (Microtus pinetorum) by using the nonparametric rank percentile method as recommended by the 2 laboratory medicine organizations mentioned. Samples of cardiac blood from a closed colony of pine voles were collected at euthanasia and evaluated under rodent settings on 2 automated hematology analyzers from 2 different manufacturers and on the same type of automated biochemistry analyzer. There were no sex-associated clinically significant differences between the sexes; younger animals had a lower hematocrit, higher mean corpuscular volume, and lower mean corpuscular hemoglobin concentration than did older animals. Only platelet counts differed when comparing hematologic values from different analyzers. Relative to rats and mice, pine voles have a lower mean corpuscular volume and higher red blood cell count, higher blood urea nitrogen, much higher alanine aminotransferase, and lower glucose and phosphorous concentrations. Hematology and plasma biochemical results obtained in this study are considered representative for healthy adult laboratory pine voles under similar environmental conditions. PMID:18702449
İnce, Fatma Demet; Ellidağ, Hamit Yaşar; Koseoğlu, Mehmet; Şimşek, Neşe; Yalçın, Hülya; Zengin, Mustafa Osman
2016-08-01
Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. 209 urine samples were analyzed by the Iris iQ200 ELITE (İris Diagnostics, USA), Dirui FUS-200 (DIRUI Industrial Co., China) automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient) and the rates within the same grading were evaluated. For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals) have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization.
CRIE: An automated analyzer for Chinese texts.
Sung, Yao-Ting; Chang, Tao-Hsing; Lin, Wei-Chun; Hsieh, Kuan-Sheng; Chang, Kuo-En
2016-12-01
Textual analysis has been applied to various fields, such as discourse analysis, corpus studies, text leveling, and automated essay evaluation. Several tools have been developed for analyzing texts written in alphabetic languages such as English and Spanish. However, currently there is no tool available for analyzing Chinese-language texts. This article introduces a tool for the automated analysis of simplified and traditional Chinese texts, called the Chinese Readability Index Explorer (CRIE). Composed of four subsystems and incorporating 82 multilevel linguistic features, CRIE is able to conduct the major tasks of segmentation, syntactic parsing, and feature extraction. Furthermore, the integration of linguistic features with machine learning models enables CRIE to provide leveling and diagnostic information for texts in language arts, texts for learning Chinese as a foreign language, and texts with domain knowledge. The usage and validation of the functions provided by CRIE are also introduced.
Vap, Linda; Bohn, Andrea A
2015-01-01
Interpretation of camelid hematology results is similar to that of other mammals. Obtaining accurate results and using appropriate reference intervals can be a bit problematic, particularly when evaluating the erythron. Camelid erythrocytes vary from other mammals in that they are small, flat, and elliptical. This variation makes data obtained from samples collected from these species prone to error when using some automated instruments. Normal and abnormal findings in camelid blood are reviewed as well as how to ensure accurate results.
Canine and feline hematology reference values for the ADVIA 120 hematology system.
Moritz, Andreas; Fickenscher, Yvonne; Meyer, Karin; Failing, Klaus; Weiss, Douglas J
2004-01-01
The ADVIA 120 is a laser-based hematology analyzer with software applications for animal species. Accurate reference values would be useful for the assessment of new hematologic parameters and for interlaboratory comparisons. The goal of this study was to establish reference intervals for CBC results and new parameters for RBC morphology, reticulocytes, and platelets in healthy dogs and cats using the ADVIA 120 hematology system. The ADVIA 120, with multispecies software (version 1.107-MS), was used to analyze whole blood samples from clinically healthy dogs (n=46) and cats (n=61). Data distribution was determined and reference intervals were calculated as 2.5 to 97.5 percentiles and 25 to 75 percentiles. Most data showed Gaussian or log-normal distribution. The numbers of RBCs falling outside the normocytic-normochromic range were slightly higher in cats than in dogs. Both dogs and cats had reticulocytes with low, medium, and high absorbance. Mean numbers of large platelets and platelet clumps were higher in cats compared with dogs. Reference intervals obtained on the ADVIA 120 provide valuable baseline information for assessing new hematologic parameters and for interlaboratory comparisons. Differences compared with previously published reference values can be attributed largely to differences in methodology.
Effects of Electromagnetic Fields on Automated Blood Cell Measurements.
Vagdatli, Eleni; Konstandinidou, Vasiliki; Adrianakis, Nikolaos; Tsikopoulos, Ioannis; Tsikopoulos, Alexios; Mitsopoulou, Kyriaki
2014-08-01
The aim of this study is to investigate whether the electromagnetic fields associated with mobile phones and/or laptops interfere with blood cell counts of hematology analyzers. Random blood samples were analyzed on an Aperture Impedance hematology analyzer. The analysis was performed in four ways: (A) without the presence of any mobile phone or portable computer in use, (B) with mobile phones in use (B1: one mobile, B4: four mobiles), (C) with portable computers (laptops) in use (C1: one laptop, C3: three laptops), and (D) with four mobile phones and three laptops in use simultaneously. The results obtained demonstrated a statistically significant decrease in neutrophil, erythrocyte, and platelet count and an increase in lymphocyte count, mean corpuscular volume, and red blood cell distribution width, notably in the B4 group. Despite this statistical significance, in clinical practice, only the red blood cell reduction could be taken into account, as the mean difference between the A and B4 group was 60,000 cells/µL. In group D, the analyzer gave odd results after 11 measurements and finally stopped working. The combined and multiple use of mobile phones and computers affects the function of hematology analyzers, leading to false results. Consequently, the use of such electronic devices must be avoided. © 2014 Society for Laboratory Automation and Screening.
NASA Astrophysics Data System (ADS)
Qiu, Yuchen; Wang, Xingwei; Chen, Xiaodong; Li, Yuhua; Liu, Hong; Li, Shibo; Zheng, Bin
2010-02-01
Visually searching for analyzable metaphase chromosome cells under microscopes is quite time-consuming and difficult. To improve detection efficiency, consistency, and diagnostic accuracy, an automated microscopic image scanning system was developed and tested to directly acquire digital images with sufficient spatial resolution for clinical diagnosis. A computer-aided detection (CAD) scheme was also developed and integrated into the image scanning system to search for and detect the regions of interest (ROI) that contain analyzable metaphase chromosome cells in the large volume of scanned images acquired from one specimen. Thus, the cytogeneticists only need to observe and interpret the limited number of ROIs. In this study, the high-resolution microscopic image scanning and CAD performance was investigated and evaluated using nine sets of images scanned from either bone marrow (three) or blood (six) specimens for diagnosis of leukemia. The automated CAD-selection results were compared with the visual selection. In the experiment, the cytogeneticists first visually searched for the analyzable metaphase chromosome cells from specimens under microscopes. The specimens were also automated scanned and followed by applying the CAD scheme to detect and save ROIs containing analyzable cells while deleting the others. The automated selected ROIs were then examined by a panel of three cytogeneticists. From the scanned images, CAD selected more analyzable cells than initially visual examinations of the cytogeneticists in both blood and bone marrow specimens. In general, CAD had higher performance in analyzing blood specimens. Even in three bone marrow specimens, CAD selected 50, 22, 9 ROIs, respectively. Except matching with the initially visual selection of 9, 7, and 5 analyzable cells in these three specimens, the cytogeneticists also selected 41, 15 and 4 new analyzable cells, which were missed in initially visual searching. This experiment showed the feasibility of
Oehadian, A; Michels, M; de Mast, Q; Prihatni, D; Puspita, M; Hartantri, Y; Sinarta, S; van der Ven, A J A M; Alisjahbana, B
2015-12-01
Distinguishing dengue virus infection from other febrile thrombocytopenic illnesses such as leptospirosis or enteric fever is important but difficult, due to the unavailability of reliable diagnostic tests. Sysmex XE-5000 hematology analyzers use fluorescence flow cytometry to quantitate new parameters including cells in the atypical lymphocyte area (AL), high-fluorescent lymphocyte counts (HFLC), immature granulocytes (IG), and immature platelets (IPF). This study aimed to investigate whether these parameters can help to discriminate between the diseases. We compared hematocytometry performed by a Sysmex XE-5000 analyzer in Indonesian adults with dengue (n = 93), leptospirosis (n = 11), and enteric fever (n = 6) infection, and in healthy controls (n = 28). Receiver operating characteristic curves comparing dengue and leptospirosis showed that dengue was characterized by increased %AL (AUC 0.87; 95% CI 0.70-1.03), %HFLC (AUC 0.89; 95% CI 0.78-0.99), and %IPF (AUC 0.81; 95% CI 0.65-0.97), while patients with leptospirosis had increased %IG (AUC 0.86; 95% CI 0.71-1.02). Low %AL, %HFLC, and %IG supported a diagnosis of enteric fever. The detection of AL, HFLC, IG, and IPF by Sysmex XE-5000 hematology analyzers can help to differentiate between common causes of febrile illnesses with thrombocytopenia in dengue endemic areas. We recommend further investigating the discriminatory value of these parameters in clinical practice. © 2015 John Wiley & Sons Ltd.
Analyzing the Cohesion of English Text and Discourse with Automated Computer Tools
ERIC Educational Resources Information Center
Jeon, Moongee
2014-01-01
This article investigates the lexical and discourse features of English text and discourse with automated computer technologies. Specifically, this article examines the cohesion of English text and discourse with automated computer tools, Coh-Metrix and TEES. Coh-Metrix is a text analysis computer tool that can analyze English text and discourse…
Hematology of healthy Florida manatees (Trichechus manatus).
Harvey, John W; Harr, Kendal E; Murphy, David; Walsh, Michael T; Nolan, Elizabeth C; Bonde, Robert K; Pate, Melanie G; Deutsch, Charles J; Edwards, Holly H; Clapp, William L
2009-06-01
Hematologic analysis is an important tool in evaluating the general health status of free-ranging manatees and in the diagnosis and monitoring of rehabilitating animals. The purpose of this study was to evaluate diagnostically important hematologic analytes in healthy manatees (Trichechus manatus) and to assess variations with respect to location (free ranging vs captive), age class (small calves, large calves, subadults, and adults), and gender. Blood was collected from 55 free-ranging and 63 captive healthy manatees. Most analytes were measured using a CELL-DYN 3500R; automated reticulocytes were measured with an ADVIA 120. Standard manual methods were used for differential leukocyte counts, reticulocyte and Heinz body counts, and plasma protein and fibrinogen concentrations. Rouleaux, slight polychromasia, stomatocytosis, and low numbers of schistocytes and nucleated RBCs (NRBCs) were seen often in stained blood films. Manual reticulocyte counts were higher than automated reticulocyte counts. Heinz bodies were present in erythrocytes of most manatees. Compared with free-ranging manatees, captive animals had slightly lower MCV, MCH, and eosinophil counts and slightly higher heterophil and NRBC counts, and fibrinogen concentration. Total leukocyte, heterophil, and monocyte counts tended to be lower in adults than in younger animals. Small calves tended to have higher reticulocyte counts and NRBC counts than older animals. Hematologic findings were generally similar between captive and free-ranging manatees. Higher manual reticulocyte counts suggest the ADVIA detects only reticulocytes containing large amounts of RNA. Higher reticulocyte and NRBC counts in young calves probably reflect an increased rate of erythropoiesis compared with older animals.
Performance Evaluation of the Sysmex CS-5100 Automated Coagulation Analyzer.
Chen, Liming; Chen, Yu
2015-01-01
Coagulation testing is widely applied clinically, and laboratories increasingly demand automated coagulation analyzers with short turn-around times and high-throughput. The purpose of this study was to evaluate the performance of the Sysmex CS-5100 automated coagulation analyzer for routine use in a clinical laboratory. The prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (APTT), fibrinogen (Fbg), and D-dimer were compared between the Sysmex CS-5100 and Sysmex CA-7000 analyzers, and the imprecision, comparison, throughput, STAT function, and performance for abnormal samples were measured in each. The within-run and between-run coefficients of variation (CV) for the PT, APTT, INR, and D-dimer analyses showed excellent results both in the normal and pathologic ranges. The correlation coefficients between the Sysmex CS-5100 and Sysmex CA-7000 were highly correlated. The throughput of the Sysmex CS-5100 was faster than that of the Sysmex CA-7000. There was no interference at all by total bilirubin concentrations and triglyceride concentrations in the Sysmex CS-5100 analyzer. We demonstrated that the Sysmex CS-5100 performs with satisfactory imprecision and is well suited for coagulation analysis in laboratories processing large sample numbers and icteric and lipemic samples.
Hedberg, P; Lehto, T
2009-02-01
This study presents the results of an aging stability study of complete blood count (CBC) and leukocyte differential parameters using the Abbott CELL-DYN Sapphire hematology analyzer. Stability studies showed no substantial change in CBC parameters up to 24-48 h at +23 +/- 2 degrees C (room temperature), except for optical platelet count (PLTo). For specimens aged over 24, the value of impedance platelet count yielded more reliable results than the routine PLTo. White blood cell (WBC) differential parameters, except eosinophils, were stable for up to 48 h at +23 +/- 2 degrees C. CBC parameters were stable for 72 h, except mean platelet volume, which slightly increased between 48 and 72 h, at +4 degrees C. WBC differentials were stable 48-72 h, with a slight decrease observed in absolute neutrophils and lymphocytes at +4 degrees C.
Hematology of healthy Florida manatees (Trichechus manatus)
Harvey, J.W.; Harr, K.E.; Murphy, D.; Walsh, M.T.; Nolan, E.C.; Bonde, R.K.; Pate, M.G.; Deutsch, C.J.; Edwards, H.H.; Clapp, W.L.
2009-01-01
Background: Hematologic analysis is an important tool in evaluating the general health status of free-ranging manatees and in the diagnosis and monitoring of rehabilitating animals. Objectives: The purpose of this study was to evaluate diagnostically important hematologic analytes in healthy manatees (Trichechus manatus) and to assess variations with respect to location (free ranging vs captive), age class (small calves, large calves, subadults, and adults), and gender. Methods: Blood was collected from 55 free-ranging and 63 captive healthy manatees. Most analytes were measured using a CELL-DYN 3500R; automated reticulocytes were measured with an ADVIA 120. Standard manual methods were used for differential leukocyte counts, reticulocyte and Heinz body counts, and plasma protein and fibrinogen concentrations. Results: Rouleaux, slight polychromasia, stomatocytosis, and low numbers of schistocytes and nucleated RBCs (NRBCs) were seen often in stained blood films. Manual reticulocyte counts were higher than automated reticulocyte counts. Heinz bodies were present in erythrocytes of most manatees. Compared with free-ranging manatees, captive animals had slightly lower MCV, MCH, and eosinophil counts and slightly higher heterophil and NRBC counts, and fibrinogen concentration. Total leukocyte, heterophil, and monocyte counts tended to be lower in adults than in younger animals. Small calves tended to have higher reticulocyte counts and NRBC counts than older animals. Conclusions: Hematologic findings were generally similar between captive and free-ranging manatees. Higher manual reticulocyte counts suggest the ADVIA detects only reticulocytes containing large amounts of RNA. Higher reticulocyte and NRBC counts in young calves probably reflect an increased rate of erythropoiesis compared with older animals. ?? 2009 American Society for Veterinary Clinical Pathology.
ICSH guidelines for the verification and performance of automated cell counters for body fluids.
Bourner, G; De la Salle, B; George, T; Tabe, Y; Baum, H; Culp, N; Keng, T B
2014-12-01
One of the many challenges facing laboratories is the verification of their automated Complete Blood Count cell counters for the enumeration of body fluids. These analyzers offer improved accuracy, precision, and efficiency in performing the enumeration of cells compared with manual methods. A patterns of practice survey was distributed to laboratories that participate in proficiency testing in Ontario, Canada, the United States, the United Kingdom, and Japan to determine the number of laboratories that are testing body fluids on automated analyzers and the performance specifications that were performed. Based on the results of this questionnaire, an International Working Group for the Verification and Performance of Automated Cell Counters for Body Fluids was formed by the International Council for Standardization in Hematology (ICSH) to prepare a set of guidelines to help laboratories plan and execute the verification of their automated cell counters to provide accurate and reliable results for automated body fluid counts. These guidelines were discussed at the ICSH General Assemblies and reviewed by an international panel of experts to achieve further consensus. © 2014 John Wiley & Sons Ltd.
Ma, Junlong; Wang, Chengbin; Yue, Jiaxin; Li, Mianyang; Zhang, Hongrui; Ma, Xiaojing; Li, Xincui; Xue, Dandan; Qing, Xiaoyan; Wang, Shengjiang; Xiang, Daijun; Cong, Yulong
2013-01-01
Several automated urine sediment analyzers have been introduced to clinical laboratories. Automated microscopic pattern recognition is a new technique for urine particle analysis. We evaluated the analytical and diagnostic performance of the UriSed automated microscopic analyzer and compared with manual microscopy for urine sediment analysis. Precision, linearity, carry-over, and method comparison were carried out. A total of 600 urine samples sent for urinalysis were assessed using the UriSed automated microscopic analyzer and manual microscopy. Within-run and between-run precision of the UriSed for red blood cells (RBC) and white blood cells (WBC) were acceptable at all levels (CV < 20%). Within-run and between-run imprecision of the UriSed testing for cast, squamous epithelial cells (EPI), and bacteria (BAC) were good at middle level and high level (CV < 20%). The linearity analysis revealed substantial agreement between the measured value and the theoretical value of the UriSed for RBC, WBC, cast, EPI, and BAC (r > 0.95). There was no carry-over. RBC, WBC, and squamous epithelial cells with sensitivities and specificities were more than 80% in this study. There is substantial agreement between the UriSed automated microscopic analyzer and the manual microscopy methods. The UriSed provides for a rapid turnaround time.
[The laboratory of tomorrow. Particular reference to hematology].
Cazal, P
1985-01-01
A serious prediction can only be an extrapolation of recent developments. To be exact, the development has to continue in the same direction, which is only a probability. Probable development of hematological technology: Progress in methods. Development of new labelling methods: radio-elements, antibodies. Monoclonal antibodies. Progress in equipment: Cell counters and their adaptation to routine hemograms is a certainty. From analyzers: a promise that will perhaps become reality. Coagulometers: progress still to be made. Hemagglutination detectors and their application to grouping: good achievements, but the market is too limited. Computerization and automation: What form will the computerizing take? What will the computer do? Who will the computer control? What should the automatic analyzers be? Two current levels. Relationships between the automatic analysers and the computer. rapidity, fidelity and above all, reliability. Memory: large capacity and easy access. Disadvantages: conservatism and technical dependency. How can they be avoided? Development of the environment: Laboratory input: outside supplies, electricity, reagents, consumables. Samples and their identification. Output: distribution of results and communication problems. Centralization or decentralization? What will tomorrow's laboratory be? 3 hypotheses: optimistic, pessimistic, and balanced.
Muliya, Sanath Krishna; Bhat, Mudraje Narayana
2016-08-01
To study the hematology and serum biochemistry parameters of Indian spectacled cobra (Naja naja) and Indian rat snake (Ptyas mucosa) and to evaluate the differences in the same between captive and wild populations. Animals were categorized into four groups, viz., wild Indian spectacled cobra (n=10), wild Indian rat snakes (n=10), captive Indian spectacled cobra (n=10), and captive Indian rat snake (n=10). The snakes were restrained with restraint tubes, and 2 ml of blood was collected from either heart or ventral coccygeal vein. Hematological examinations were performed manually and serum biochemistry assays were performed on semi-automated clinical chemistry analyzer. The values of total erythrocyte count, packed cell volume, and hemoglobin were slightly low in captive spectacled cobras and captive rat snakes compared to wild ones, whereas total leukocyte count was found to be slightly high in wild spectacled cobras compared to captive ones. All the recorded values of biochemical and electrolyte analytes were found to be well within expected range for snakes except for total protein and chloride levels in both the species which was slightly above the expected range. The hematology and serum biochemistry intervals of the two most common Indian snakes are presented here. The data will be useful in routine health evaluations and aiding in better medical management of the species studied. Since this study is the first to report complete hematologic and blood biochemical ranges for the study species, observations made here can also be used as referral intervals for future use.
The optics inside an automated single molecule array analyzer
NASA Astrophysics Data System (ADS)
McGuigan, William; Fournier, David R.; Watson, Gary W.; Walling, Les; Gigante, Bill; Duffy, David C.; Rissin, David M.; Kan, Cheuk W.; Meyer, Raymond E.; Piech, Tomasz; Fishburn, Matthew W.
2014-02-01
Quanterix and Stratec Biomedical have developed an instrument that enables the automated measurement of multiple proteins at concentration ~1000 times lower than existing immunoassays. The instrument is based on Quanterix's proprietary Single Molecule Array technology (Simoa™ ) that facilitates the detection and quantification of biomarkers previously difficult to measure, thus opening up new applications in life science research and in-vitro diagnostics. Simoa is based on trapping individual beads in arrays of femtoliter-sized wells that, when imaged with sufficient resolution, allows for counting of single molecules associated with each bead. When used to capture and detect proteins, this approach is known as digital ELISA (Enzyme-linked immunosorbent assay). The platform developed is a merger of many science and engineering disciplines. This paper concentrates on the optical technologies that have enabled the development of a fully-automated single molecule analyzer. At the core of the system is a custom, wide field-of-view, fluorescence microscope that images arrays of microwells containing single molecules bound to magnetic beads. A consumable disc containing 24 microstructure arrays was developed previously in collaboration with Sony DADC. The system cadence requirements, array dimensions, and requirement to detect single molecules presented significant optical challenges. Specifically, the wide field-of-view needed to image the entire array resulted in the need for a custom objective lens. Additionally, cost considerations for the system required a custom solution that leveraged the image processing capabilities. This paper will discuss the design considerations and resultant optical architecture that has enabled the development of an automated digital ELISA platform.
A Novel Automated Method for Analyzing Cylindrical Computed Tomography Data
NASA Technical Reports Server (NTRS)
Roth, D. J.; Burke, E. R.; Rauser, R. W.; Martin, R. E.
2011-01-01
A novel software method is presented that is applicable for analyzing cylindrical and partially cylindrical objects inspected using computed tomography. This method involves unwrapping and re-slicing data so that the CT data from the cylindrical object can be viewed as a series of 2-D sheets in the vertical direction in addition to volume rendering and normal plane views provided by traditional CT software. The method is based on interior and exterior surface edge detection and under proper conditions, is FULLY AUTOMATED and requires no input from the user except the correct voxel dimension from the CT scan. The software is available from NASA in 32- and 64-bit versions that can be applied to gigabyte-sized data sets, processing data either in random access memory or primarily on the computer hard drive. Please inquire with the presenting author if further interested. This software differentiates itself in total from other possible re-slicing software solutions due to complete automation and advanced processing and analysis capabilities.
Automated Root Tracking with "Root System Analyzer"
NASA Astrophysics Data System (ADS)
Schnepf, Andrea; Jin, Meina; Ockert, Charlotte; Bol, Roland; Leitner, Daniel
2015-04-01
Crucial factors for plant development are water and nutrient availability in soils. Thus, root architecture is a main aspect of plant productivity and needs to be accurately considered when describing root processes. Images of root architecture contain a huge amount of information, and image analysis helps to recover parameters describing certain root architectural and morphological traits. The majority of imaging systems for root systems are designed for two-dimensional images, such as RootReader2, GiA Roots, SmartRoot, EZ-Rhizo, and Growscreen, but most of them are semi-automated and involve mouse-clicks in each root by the user. "Root System Analyzer" is a new, fully automated approach for recovering root architectural parameters from two-dimensional images of root systems. Individual roots can still be corrected manually in a user interface if required. The algorithm starts with a sequence of segmented two-dimensional images showing the dynamic development of a root system. For each image, morphological operators are used for skeletonization. Based on this, a graph representation of the root system is created. A dynamic root architecture model helps to determine which edges of the graph belong to an individual root. The algorithm elongates each root at the root tip and simulates growth confined within the already existing graph representation. The increment of root elongation is calculated assuming constant growth. For each root, the algorithm finds all possible paths and elongates the root in the direction of the optimal path. In this way, each edge of the graph is assigned to one or more coherent roots. Image sequences of root systems are handled in such a way that the previous image is used as a starting point for the current image. The algorithm is implemented in a set of Matlab m-files. Output of Root System Analyzer is a data structure that includes for each root an identification number, the branching order, the time of emergence, the parent
Özen, Mehmet; Yılmaz, Gülden; Coşkun, Belgin; Topçuoğlu, Pervin; Öztürk, Bengi; Gündüz, Mehmet; Atilla, Erden; Arslan, Önder; Özcan, Muhit; Demirer, Taner; İlhan, Osman; Konuk, Nahide; Balık, İsmail; Gürman, Günhan; Akan, Hamdi
2016-01-01
Objective: The increased risk of infection for patients caused by construction and renovation near hematology inpatient clinics is a major concern. The use of high-efficiency particulate absorption (HEPA) filters can reduce the risk of infection. However, there is no standard protocol indicating the use of HEPA filters for patients with hematological malignancies, except for those who have undergone allogeneic hematopoietic stem cell transplantation. This quasi-experimental study was designed to measure the efficacy of HEPA filters in preventing infections during construction. Materials and Methods: Portable HEPA filters were placed in the rooms of patients undergoing treatment for hematological malignancies because of large-scale construction taking place near the hematology clinic. The rates of infection during the 6 months before and after the installation of the portable HEPA filters were compared. A total of 413 patients were treated during this 1-year period. Results: There were no significant differences in the antifungal prophylaxis and treatment regimens between the groups. The rates of infections, clinically documented infections, and invasive fungal infections decreased in all of the patients following the installation of the HEPA filters. When analyzed separately, the rates of invasive fungal infections were similar before and after the installation of HEPA filters in patients who had no neutropenia or long neutropenia duration. HEPA filters were significantly protective against infection when installed in the rooms of patients with acute lymphocytic leukemia, patients who were undergoing consolidation treatment, and patients who were neutropenic for 1-14 days. Conclusion: Despite the advent of construction and the summer season, during which environmental Aspergillus contamination is more prevalent, no patient or patient subgroup experienced an increase in fungal infections following the installation of HEPA filters. The protective effect of HEPA
Özen, Mehmet; Yılmaz, Gülden; Coşkun, Belgin; Topçuoğlu, Pervin; Öztürk, Bengi; Gündüz, Mehmet; Atilla, Erden; Arslan, Önder; Özcan, Muhit; Demirer, Taner; İlhan, Osman; Konuk, Nahide; Balık, İsmail; Gürman, Günhan; Akan, Hamdi
2016-03-05
The increased risk of infection for patients caused by construction and renovation near hematology inpatient clinics is a major concern. The use of high-efficiency particulate absorption (HEPA) filters can reduce the risk of infection. However, there is no standard protocol indicating the use of HEPA filters for patients with hematological malignancies, except for those who have undergone allogeneic hematopoietic stem cell transplantation. This quasi-experimental study was designed to measure the efficacy of HEPA filters in preventing infections during construction. Portable HEPA filters were placed in the rooms of patients undergoing treatment for hematological malignancies because of large-scale construction taking place near the hematology clinic. The rates of infection during the 6 months before and after the installation of the portable HEPA filters were compared. A total of 413 patients were treated during this 1-year period. There were no significant differences in the antifungal prophylaxis and treatment regimens between the groups. The rates of infections, clinically documented infections, and invasive fungal infections decreased in all of the patients following the installation of the HEPA filters. When analyzed separately, the rates of invasive fungal infections were similar before and after the installation of HEPA filters in patients who had no neutropenia or long neutropenia duration. HEPA filters were significantly protective against infection when installed in the rooms of patients with acute lymphocytic leukemia, patients who were undergoing consolidation treatment, and patients who were neutropenic for 1-14 days. Despite the advent of construction and the summer season, during which environmental Aspergillus contamination is more prevalent, no patient or patient subgroup experienced an increase in fungal infections following the installation of HEPA filters. The protective effect of HEPA filters against infection was more pronounced in patients
BMC Blood Disorders becomes BMC Hematology: evolving along with the hematology field.
Chap, Christna
2013-04-10
This Editorial marks the launch of BMC Hematology, formerly known as BMC Blood Disorders, within the BMC series of journals published by BioMed Central. The scope of BMC Hematology encompasses basic, experimental and clinical research related to hematology. In this Editorial we will discuss the rationale behind this relaunch and how, as an open access journal providing unrestricted and free access to scientific and scholarly work, BMC Hematology will help disseminate research in the hematology field in a freely-accessible manner.
2015-08-18
SECURITY CLASSIFICATION OF: Arena 60 Discrete Photometric Analyzer System and ancillary instrumentation were acquired to increase our analytical...Infrastructure at West Virginia State University Report Title Arena 60 Discrete Photometric Analyzer System and ancillary instrumentation were acquired...Progress Principal Accomplishments: a. One Postdoctoral fellow was trained using the automated Arena 60 Discrete Photometric Analyzer and
BMC Blood Disorders becomes BMC Hematology: evolving along with the hematology field
2013-01-01
This Editorial marks the launch of BMC Hematology, formerly known as BMC Blood Disorders, within the BMC series of journals published by BioMed Central. The scope of BMC Hematology encompasses basic, experimental and clinical research related to hematology. In this Editorial we will discuss the rationale behind this relaunch and how, as an open access journal providing unrestricted and free access to scientific and scholarly work, BMC Hematology will help disseminate research in the hematology field in a freely-accessible manner. PMID:24499661
[Evaluation of the Abbott Cell-Dyn Sapphire hematology analyzer].
Park, Younhee; Song, Jaewoo; Song, Sungwook; Song, Kyung Soon; Ahn, Mee Suk; Yang, Mi-Sook; Kim, Il; Choi, Jong Rak
2007-06-01
The performance of Cell-Dyn Sapphire (Abbott Diagnostic, USA) was compared to the Bayer Advia 2120 (Bayer Diagnostics, USA), Sysmex XE-2100 (Sysmex Corporation, Japan), and reference microscopy. Three hundred samples for routine CBC and WBC differentials were randomly chosen for a comparison analysis. The Cell-Dyn Sapphire system was evaluated according to the linearity, imprecision, inter-instrument correlations, and white blood cell differential. The CBC parameters (WBC, RBC, hemoglobin and platelet) showed a significant linearity with correlation coefficients greater than 0.99 (P<0.0001). Coefficients of variation (CV) for within-run and differential count of WBC were less than 5% except for Total CV for monocytes, eosinophils, and basophils and within-run CV for low valued eosinophils. The correlation coefficients with manual count were lower in monocytes, eosinophils, and basophils than in neutrophils and lymphocytes. The correlation with other hematology anlayzers was significant exclusive of basophils. These results demonstrate that the Cell-Dyn Sapphire has a good linearity, an acceptable reproducibility, a minimal carryover, and a comparable performance with the sysmex XE-2100 and Advia 2120.
Alvarez-Ortega, Neda; Caballero-Gallardo, Karina; Olivero-Verbel, Jesus
2017-12-01
Lead produces numerous biochemical and physiological changes in humans, including hematological disorders, toxic effects on the central nervous system and in the function of several organs. The aim of this study was to determine blood lead levels (BLL) in children from Cartagena, Colombia, associating those with hematological and liver damage markers, the intelligence quotient (IQ), as well as with gene expression of the aminolevulinate dehydratase (ALAD), superoxide dismutase 1 (SOD1), gamma interferon (INF-γ), tumor necrosis factor (TNF) and tumor protein (p53). To achieve this purpose, 118 blood samples were collected from children 5-16 years old, with their respective informed consent from their parents. BLL was measured by atomic absorption; hematological parameters were obtained with automated systems; plasma was utilized to analyze hepatic toxicity markers, alanine aminotransferase (ALT), gamma-glutamyltransferase (γ-GT) and alkaline phosphatase (ALP); the Kaufman Brief Intelligence Test (K-BIT) was administered to measure the IQ; and gene expression was quantified from blood RNA. The mean BLL was 1.7±0.3μg/dL. A low proportion of the children (3.4%) had BLL above the CDC recommended limit (5μg/dL). BLL were correlated weakly, but negatively with child age, weight, height, body mass index, platelets wide distribution, mean platelet volume, γ-GT and IQ. There were not significant changes in the expression of evaluated genes. These results support the hypothesis that BLL below 5μg/dL may still be a detrimental factor on children's cognitive abilities, development and hematology, in line with recent concerns that there is no safe level of pediatric lead exposure. Copyright © 2017 Elsevier GmbH. All rights reserved.
42 CFR 493.941 - Hematology (including routine hematology and coagulation).
Code of Federal Regulations, 2013 CFR
2013-10-01
... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...
42 CFR 493.941 - Hematology (including routine hematology and coagulation).
Code of Federal Regulations, 2014 CFR
2014-10-01
... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...
42 CFR 493.941 - Hematology (including routine hematology and coagulation).
Code of Federal Regulations, 2010 CFR
2010-10-01
... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...
42 CFR 493.941 - Hematology (including routine hematology and coagulation).
Code of Federal Regulations, 2012 CFR
2012-10-01
... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...
42 CFR 493.941 - Hematology (including routine hematology and coagulation).
Code of Federal Regulations, 2011 CFR
2011-10-01
... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...
21 CFR 864.3800 - Automated slide stainer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Automated slide stainer. 864.3800 Section 864.3800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3800...
21 CFR 864.3875 - Automated tissue processor.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated tissue processor. 864.3875 Section 864.3875 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3875...
21 CFR 864.3875 - Automated tissue processor.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Automated tissue processor. 864.3875 Section 864.3875 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3875...
21 CFR 864.3875 - Automated tissue processor.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated tissue processor. 864.3875 Section 864.3875 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3875...
21 CFR 864.3875 - Automated tissue processor.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Automated tissue processor. 864.3875 Section 864.3875 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3875...
21 CFR 864.3800 - Automated slide stainer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated slide stainer. 864.3800 Section 864.3800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3800...
21 CFR 864.3875 - Automated tissue processor.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Automated tissue processor. 864.3875 Section 864.3875 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3875...
21 CFR 864.3800 - Automated slide stainer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Automated slide stainer. 864.3800 Section 864.3800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3800...
21 CFR 864.3800 - Automated slide stainer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated slide stainer. 864.3800 Section 864.3800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3800...
21 CFR 864.3800 - Automated slide stainer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Automated slide stainer. 864.3800 Section 864.3800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3800...
The European Hematology Association Roadmap for European Hematology Research: a consensus document.
Engert, Andreas; Balduini, Carlo; Brand, Anneke; Coiffier, Bertrand; Cordonnier, Catherine; Döhner, Hartmut; de Wit, Thom Duyvené; Eichinger, Sabine; Fibbe, Willem; Green, Tony; de Haas, Fleur; Iolascon, Achille; Jaffredo, Thierry; Rodeghiero, Francesco; Salles, Gilles; Schuringa, Jan Jacob
2016-02-01
The European Hematology Association (EHA) Roadmap for European Hematology Research highlights major achievements in diagnosis and treatment of blood disorders and identifies the greatest unmet clinical and scientific needs in those areas to enable better funded, more focused European hematology research. Initiated by the EHA, around 300 experts contributed to the consensus document, which will help European policy makers, research funders, research organizations, researchers, and patient groups make better informed decisions on hematology research. It also aims to raise public awareness of the burden of blood disorders on European society, which purely in economic terms is estimated at €23 billion per year, a level of cost that is not matched in current European hematology research funding. In recent decades, hematology research has improved our fundamental understanding of the biology of blood disorders, and has improved diagnostics and treatments, sometimes in revolutionary ways. This progress highlights the potential of focused basic research programs such as this EHA Roadmap.The EHA Roadmap identifies nine 'sections' in hematology: normal hematopoiesis, malignant lymphoid and myeloid diseases, anemias and related diseases, platelet disorders, blood coagulation and hemostatic disorders, transfusion medicine, infections in hematology, and hematopoietic stem cell transplantation. These sections span 60 smaller groups of diseases or disorders.The EHA Roadmap identifies priorities and needs across the field of hematology, including those to develop targeted therapies based on genomic profiling and chemical biology, to eradicate minimal residual malignant disease, and to develop cellular immunotherapies, combination treatments, gene therapies, hematopoietic stem cell treatments, and treatments that are better tolerated by elderly patients. Copyright© Ferrata Storti Foundation.
The European Hematology Association Roadmap for European Hematology Research: a consensus document
Engert, Andreas; Balduini, Carlo; Brand, Anneke; Coiffier, Bertrand; Cordonnier, Catherine; Döhner, Hartmut; de Wit, Thom Duyvené; Eichinger, Sabine; Fibbe, Willem; Green, Tony; de Haas, Fleur; Iolascon, Achille; Jaffredo, Thierry; Rodeghiero, Francesco; Salles, Gilles; Schuringa, Jan Jacob
2016-01-01
The European Hematology Association (EHA) Roadmap for European Hematology Research highlights major achievements in diagnosis and treatment of blood disorders and identifies the greatest unmet clinical and scientific needs in those areas to enable better funded, more focused European hematology research. Initiated by the EHA, around 300 experts contributed to the consensus document, which will help European policy makers, research funders, research organizations, researchers, and patient groups make better informed decisions on hematology research. It also aims to raise public awareness of the burden of blood disorders on European society, which purely in economic terms is estimated at €23 billion per year, a level of cost that is not matched in current European hematology research funding. In recent decades, hematology research has improved our fundamental understanding of the biology of blood disorders, and has improved diagnostics and treatments, sometimes in revolutionary ways. This progress highlights the potential of focused basic research programs such as this EHA Roadmap. The EHA Roadmap identifies nine ‘sections’ in hematology: normal hematopoiesis, malignant lymphoid and myeloid diseases, anemias and related diseases, platelet disorders, blood coagulation and hemostatic disorders, transfusion medicine, infections in hematology, and hematopoietic stem cell transplantation. These sections span 60 smaller groups of diseases or disorders. The EHA Roadmap identifies priorities and needs across the field of hematology, including those to develop targeted therapies based on genomic profiling and chemical biology, to eradicate minimal residual malignant disease, and to develop cellular immunotherapies, combination treatments, gene therapies, hematopoietic stem cell treatments, and treatments that are better tolerated by elderly patients. PMID:26819058
Jenkins, Sarah; Mikhael, Joseph; Gitlin, Scott D.
2018-01-01
Nonmalignant hematologic conditions are extremely prevalent and contribute significantly to the global burden of disease. The US health care system may soon face a shortage of specialists in nonmalignant hematology. We sought to identify factors that lead hematology-oncology fellows to pursue (or not to pursue) careers in nonmalignant hematology. Cross-sectional, web-based survey distributed to 149 graduates of a hematology-oncology fellowship program at a large academic medical center between 1998 and 2016. Eighty-six out of 149 graduates responded (57.7%); most (59 [68.6%]) practice at an academic medical center. Respondents spend a mean of 61% of their time in clinical practice, 23.7% conducting research, 5.2% in education, and 5.2% in administration. Those in clinical practice spend a mean of 52.1% of their time in solid tumor oncology, 37.5% in hematologic malignancies, and 10% in nonmalignant hematology; only 1 spent >50% of time practicing nonmalignant hematology. Factors most significantly affecting choice of patient population included clinical experience during fellowship and intellectual stimulation of the patient population/disease type. Factors that could have most significantly influenced a decision to spend more time in nonmalignant hematology included increased exposure/access to role models and mentors and opportunities for better career growth/advancement. Fellowship graduates spend >50% of their time in clinical practice, but almost none spend a significant amount of time practicing nonmalignant hematology. Given the growing number of patients with nonmalignant hematologic conditions and a possible future provider shortage, medical trainees should be encouraged to pursue careers in nonmalignant hematology. PMID:29463548
Escobar, Carlos; Moniz, Marta; Nunes, Pedro; Abadesso, Clara; Ferreira, Teresa; Barra, António; Lichtner, Anabela; Loureiro, Helena; Dias, Alexandra; Almeida, Helena
2017-10-31
The benefits of manual versus automated red blood cell exchange have rarely been documented and studies in young sickle cell disease patients are scarce. We aim to describe and compare our experience in these two procedures. Young patients (≤ 21 years old) who underwent manual- or automated-red blood cell exchange for prevention or treatment of sickle cell disease complications were included. Clinical, technical and hematological data were prospectively recorded and analyzed. Ninety-four red blood cell exchange sessions were performed over a period of 68 months, including 57 manual and 37 automated, 63 for chronic complications prevention, 30 for acute complications and one in the pre-operative setting. Mean decrease in sickle hemoglobin levels was higher in automated-red blood cell exchange (p < 0.001) and permitted a higher sickle hemoglobin level decrease per volume removed (p < 0.001), while hemoglobin and hematocrit remained stable. Ferritin levels on chronic patients decreased 54%. Most frequent concern was catheter outflow obstruction on manual-red blood cell exchange and access alarm on automated-red blood cell exchange. No major complication or alloimunization was recorded. Automated-red blood cell exchange decreased sickle hemoglobin levels more efficiently than manual procedure in the setting of acute and chronic complications of sickle cell disease, with minor technical concerns mainly due to vascular access. The threshold of sickle hemoglobin should be individualized for clinical and hematological goals. In our cohort of young patients, the need for an acceptable venous access was a limiting factor, but iron-overload was avoided. Automated red blood cell exchange is safe and well tolerated. It permits a higher sickle hemoglobin removal efficacy, better volume status control and iron-overload avoidance.
Employee Engagement Is Vital for the Successful Selection of a Total Laboratory Automation System.
Yu, Hoi-Ying E; Wilkerson, Myra L
2017-11-08
To concretely outline a process for selecting a total laboratory automation system that connects clinical chemistry, hematology, and coagulation analyzers and to serve as a reference for other laboratories. In Phase I, a committee including the laboratory's directors and technologists conducted a review of 5 systems based on formal request for information process, site visits, and vendor presentations. We developed evaluation criteria and selected the 2 highest performing systems. In Phase II, we executed a detailed comparison of the 2 vendors based on cost, instrument layout, workflow design, and future potential. In addition to selecting a laboratory automation system, we used the process to ensure employee engagement in preparation for implementation. Selecting a total laboratory automation system is a complicated process. This paper provides practical guide in how a thorough selection process can be done with participation of key stakeholders. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Elbeik, Tarek; Loftus, Richard A; Beringer, Scott
2007-11-01
Labor, supply and waste were evaluated for HIV-1 and HCV bDNA on the semi-automated System 340 bDNA Analyzer and the automated VERSANT 440 Molecular System (V440). HIV-1 sample processing was evaluated using a 24- and 48-position centrifuge rotor. Vigilance time (hands-on manipulations plus incubation time except initial target hybridization) and disposables were approximately 37 and 12% lower for HIV-1, and 64 and 31% lower for HCV bDNA, respectively, with V440. Biohazardous solid waste was approximately twofold lower for both assays and other waste types were the same for either assay on both platforms. HIV-1 sample processing vigilance time for the 48-position rotor was reduced by 2 h. V440 provides cost savings and improved workflow.
Drug-Induced Hematologic Syndromes
Mintzer, David M.; Billet, Shira N.; Chmielewski, Lauren
2009-01-01
Objective. Drugs can induce almost the entire spectrum of hematologic disorders, affecting white cells, red cells, platelets, and the coagulation system. This paper aims to emphasize the broad range of drug-induced hematological syndromes and to highlight some of the newer drugs and syndromes. Methods. Medline literature on drug-induced hematologic syndromes was reviewed. Most reports and reviews focus on individual drugs or cytopenias. Results. Drug-induced syndromes include hemolytic anemias, methemoglobinemia, red cell aplasia, sideroblastic anemia, megaloblastic anemia, polycythemia, aplastic anemia, leukocytosis, neutropenia, eosinophilia, immune thrombocytopenia, microangiopathic syndromes, hypercoagulability, hypoprothrombinemia, circulating anticoagulants, myelodysplasia, and acute leukemia. Some of the classic drugs known to cause hematologic abnormalities have been replaced by newer drugs, including biologics, accompanied by their own syndromes and unintended side effects. Conclusions. Drugs can induce toxicities spanning many hematologic syndromes, mediated by a variety of mechanisms. Physicians need to be alert to the potential for iatrogenic drug-induced hematologic complications. PMID:19960059
Gokce, M; Bilginer, Y; Besbas, N; Ozaltin, F; Cetin, M; Gumruk, F; Ozen, S
2012-07-01
The aim of this study was to analyze the hematological features in children with systemic lupus erythematosus (SLE) and to review our current treatment protocols. We evaluated hematological findings of 43 children with SLE diagnosed and followed at the Pediatric Rheumatology Division of Hacettepe University, Turkey. Thirty-seven patients with hematological abnormalities were analyzed in detail. Median age at presentation was 13 years. Hematological involvement was seen in 86% of patients. The most common hematological finding was anemia (n = 30). Anemia was either a Coombs (+) hemolytic one, or was due to other causes. Hemolytic anemia was treated with steroids and intravenous gamma globulin (IVIG). Leucopenia and thrombocytopenia were detected in 35.1 % and 37.8 %, respectively. Bone marrow aspiration was performed in 15, mainly for cytopenia. Secondary dysplastic changes were common. Acute lymphoblastic leukemia (ALL) was diagnosed in one patient. Six patients were diagnosed as having macrophage activation syndrome (MAS). One patient died due to secondary infections and multiorgan failure despite aggressive treatment. In patients diagnosed early, treatment with steroids and cyclosporine resulted in an excellent response. Thrombotic microangiopathy was detected in two patients. Both were treated successfully with steroids and plasma exchange. Antiphospholipid and anticardiolipin antibodies were positive in 12 and 15 of the patients, respectively. Five developed deep vein thrombosis (DVT), one cerebral sinus thrombosis and one presented with purpura fulminans. They were effectively treated with anticoagulation protocol. Hematological findings should be carefully assessed and treated vigorously to prevent the morbidity and possible mortality.
Cold Agglutinin Disease; A Laboratory Challenge.
Nikousefat, Zahra; Javdani, Moosa; Hashemnia, Mohammad; Haratyan, Abbas; Jalili, Ali
2015-10-01
Autoimmune haemolytic anemia (AIHA) is a complex process characterized by an immune reaction against red blood cell self-antigens. The analysis of specimens, drawn from patients with cold auto-immune hemolytic anemia is a difficult problem for automated hematology analyzer. This paper was written to alert technologists and pathologists to the presence of cold agglutinins and its effect on laboratory tests. A 72-year-old female presented to the Shafa laboratory for hematology profile evaluation. CBC indices showed invalid findings with the Sysmex automated hematology analyzer. Checking the laboratory process showed precipitation residue sticking to the sides of the tube. After warming the tubes, results become valid and the problem attributed to cold agglutinin disease. In this situation, aggregation of RBCs, which occurs at t < 30°C, causes invalid findings meanwhile working with automated hematology analyzer. Knowledge of this phenomenon can help prevent wasting too much time and make an early and accurate diagnosis.
Development, history, and future of automated cell counters.
Green, Ralph; Wachsmann-Hogiu, Sebastian
2015-03-01
Modern automated hematology instruments use either optical methods (light scatter), impedance-based methods based on the Coulter principle (changes in electrical current induced by blood cells flowing through an electrically charged opening), or a combination of both optical and impedance-based methods. Progressive improvement in these instruments has allowed the enumeration and evaluation of blood cells with great accuracy, precision, and speed at very low cost. Future directions of hematology instrumentation include the addition of new parameters and the development of point-of-care instrumentation. In the future, in-vivo analysis of blood cells may allow noninvasive and near-continuous measurements. Copyright © 2015 Elsevier Inc. All rights reserved.
Analyzing Automated Instructional Systems: Metaphors from Related Design Professions.
ERIC Educational Resources Information Center
Jonassen, David H.; Wilson, Brent G.
Noting that automation has had an impact on virtually every manufacturing and information operation in the world, including instructional design (ID), this paper suggests three basic metaphors for automating instructional design activities: (1) computer-aided design and manufacturing (CAD/CAM) systems; (2) expert system advisor systems; and (3)…
Hematological reference values of healthy Malaysian population.
Roshan, T M; Rosline, H; Ahmed, S A; Rapiaah, M; Wan Zaidah, A; Khattak, M N
2009-10-01
Health and disease can only be distinguished by accurate and reliable reference values of a particular laboratory test. It is now a proven fact that there is considerable variation in hematology reference intervals depending on the demographic and preanalytical variables. There are evidences that values provided by manufacturers do not have appropriate application for all populations. Moreover, reference ranges provided by different laboratory manuals and books also do not solve this problem. We are presenting here normal reference ranges of Malaysian population. These values were determined by using Sysmex XE-2100 and ACL 9000 hematology and coagulation analyzers. Results from this study showed that there were considerable differences in the reference values from manufacturers, western population or laboratory manuals compared with those from the local population.
Murussi, Camila R; Menezes, Charlene C; Nunes, Mauro E M; Araújo, Maria do Carmo S; Quadros, Vanessa A; Rosemberg, Denis B; Loro, Vania L
2016-11-01
Azadirachtin (Aza) is a promisor biopesticide used in organic production and aquaculture. Although this compound is apparently safe, there is evidence that it may have deleterious effects on fish. Behavioral and hematological tests are grouped into a set of parameters that may predict potential toxicity of chemical compounds. Here, we investigate the effects of Aza, in the commercial formulation Neenmax ™ , on carp (Cyprinus carpio) by defining LC 50 (96 h), and testing behavioral and hematological parameters. In our study, LC 50 was estimated at 80 μL/L. We exposed carp to Aza at 20, 40, and 60 μL/L, values based on 25, 50, and 75% of LC 50 , respectively. At 60 μL/L, Aza promoted significant changes in several parameters, increasing the distance traveled and absolute turn angle. In addition, the same concentration decreased the time spent immobile and the number of immobile episodes. Hematological parameters, such as hematocrit, hemoglobin, hematimetrics index, and red cell distribution, were decreased at 60 μL/L Aza exposure. In conclusion, our study demonstrates that 60 μL/L Aza altered locomotor activity, motor pattern, and hematological parameters, suggesting potential toxicity to carp after acute exposure. In addition, this is the first report that evaluates the actions of a chemical contaminant using automated behavioral tracking of carp, which may be a useful tool for assessing the potential toxicity of biopesticides in conjunction with hematological tests. © 2015 Wiley Periodicals, Inc. Environ Toxicol 31: 1381-1388, 2016. © 2015 Wiley Periodicals, Inc.
Hematological findings in children with brucellosis.
Aypak, Adalet; Aypak, Cenk; Bayram, Yasemin
2015-12-01
Brucellosis produces a variety of non-specific hematological abnormalities. The aim of the present study was to evaluate the hematological findings in childhood brucellosis. Medical records of children with brucellosis admitted to a tertiary hospital in a 1 year period, were analyzed retrospectively. Sixty-nine patients (mean age, 14.5 ± 3.3 years) were diagnosed with brucellosis. The most common hematological finding was thrombocytopenia (n = 11, 15.9%). Thrombocytosis was detected in five patients (7.3%), leukopenia in four (5.8%), anemia in three (4.3%), and bicytopenia in three (4.3%). None of the patients had pancytopenia. Blood culture was positive for Brucella spp. in 41 patients (59.4%). Among those patients with positive blood culture, six (14.6%) had serum agglutination test titer ≤1/80. Platelet (PLT) count was significantly lower in the bacteremia-positive group. The OR (95%CI) of bacteremia for PLT cut-off 200,000/mm(3) was 0.148 (95%CI: 0.031-0.718) and relative risk was 1.718 (95%CI: 1.244-2.372; P = 0.010). Brucellosis should be kept in mind in the differential diagnosis of isolated thrombocytopenia in pediatric patients from endemic areas. © 2015 Japan Pediatric Society.
Guarner, Jeannette; Atuan, Maria Ana; Nix, Barbara; Mishak, Christopher; Vejjajiva, Connie; Curtis, Cheri; Park, Sunita; Mullins, Richard
2010-01-01
Each institution sets specific parameters obtained by automated hematology analyzers to trigger manual counts. We designed a process to decrease the number of manual differential cell counts without impacting patient care. We selected new criteria that prompt manual counts and studied the impact these changes had in 2 days of work and in samples of patients with newly diagnosed leukemia, sickle cell disease, and presence of left shift. By using fewer parameters and expanding our ranges we decreased the number of manual counts by 20%. The parameters that prompted manual counts most frequently were the presence of blast flags and nucleated red blood cells, 2 parameters that were not changed. The parameters that accounted for a decrease in the number of manual counts were the white blood cell count and large unstained cells. Eight of 32 patients with newly diagnosed leukemia did not show blast flags; however, other parameters triggered manual counts. In 47 patients with sickle cell disease, nucleated red cells and red cell variability prompted manual review. Bands were observed in 18% of the specimens and 4% would not have been counted manually with the new criteria, for the latter the mean band count was 2.6%. The process we followed to evaluate hematological parameters that reflex to manual differential cell counts increased efficiency without compromising patient care in our hospital system.
Singha, Kritsada; Fucharoen, Goonnapa; Fucharoen, Supan
2015-01-01
Hemoglobin (Hb) Grey Lynn is a Hb variant caused by a mutation at codon 91 of α1-globin gene whereas Hb E is a common β-globin chain variant among Southeast Asian population. We report two hitherto undescribed conditions of Hb Grey Lynn found in Thai individuals. The study was done on two unrelated Thai subjects. Hematological parameters were recorded and Hb analysis was carried out using automated Hb analyzers. Mutations were identified by DNA analysis. Hematological features of the patients were compared with those of various forms of Hb Grey Lynn documented previously. Hb and DNA analyses identified a heterozygous Hb Grey Lynn in one patient and a double heterozygous Hb Grey Lynn and Hb E with α(+)-thalassemia in another. Interaction of α(Grey Lynn) with β(E) chains leads to the formation of a new Hb variant, namely the Hb Grey Lynn E (α(GL)2β(E)2), detectable by liquid chromatography (10.3%) but masked by Hb E on capillary electrophoresis. Interaction of these multiple globin gene defects could lead to complex hemoglobinopathies requiring combined analysis with multiple Hb analyzers followed by DNA testing to provide accurate diagnosis of the cases.
van Dievoet, M A; Louagie, H; Ghys, T
2016-10-01
The Sysmex XP-300(®) (XP-300) is a new, fully automated hematology analyzer, designed to generate complete blood counts (CBC) with 3-part differential. In our study, the XP-300 was evaluated as a point-of-care (POC) analyzer in an oncology setting. In which blood samples from patients with different pathologies and treatments, affecting hematopoiesis, were analyzed. Performance was evaluated according to the International Council for Standardization in Haematology (ICSH) guidelines and CLSI protocol H20-A2 . Beside precision, linearity and carry-over, a comparison study with the Sysmex(®) XN-3000 (XN-3000) and a manual reference leukocyte differential was performed. Flagging performance was also evaluated. XP-300 showed excellent precision and linearity results. For within- and between-run precision, the criteria, according to Ricos et al. , were met for all parameters tested, except for platelets in the low level. Less than or equal to 0.5% carry-over was seen for all parameters tested. Comparison studies showed an acceptable correlation with both XN-3000 and the manual reference leukocyte count. A suboptimal flagging performance was demonstrated. In the context of diagnosing cytopenia due to myelosuppressing agents or leukocytosis due to infection, the XP-300 showed good analytical performance. However, in the thrombocytopenic range, precision was suboptimal. In follow-up of hematological malignancies with the occurrence of abnormal cells, we advise verification with a more advanced analyzer or with microscopic review, although further studies with a higher prevalence of abnormal cells are needed. © 2016 John Wiley & Sons Ltd.
Sykes, John M; Klaphake, Eric
2015-01-01
The basic principles of hematology used in mammalian medicine can be applied to reptiles. The appearances of the blood cells are significantly different from those seen in most mammals, and vary with taxa and staining method used. Many causes for abnormalities of the reptilian hemogram are similar to those for mammals, although additional factors such as venipuncture site, season, hibernation status, captivity status, and environmental factors can also affect values, making interpretation of hematologic results challenging. Values in an individual should be compared with reference ranges specific to that species, gender, and environmental conditions when available.
Hematology and serum chemistry of free-ranging jaguars (Panthera onca).
Widmer, Cynthia E; Hagiwara, Mitika K; Ferreira, Fernando; Azevedo, Fernando C C
2012-10-01
We collected and analyzed blood samples from 12 free-ranging jaguars (Panthera onca). Clinical examinations, hematology, and serum chemistry indicate the jaguars were in good overall health. Results may help as values for free-ranging jaguars under the same handling conditions.
Hematologic problems in pediatric patients.
Cahill, M
1996-02-01
To provide a review of the common hematologic disorders of childhood: iron deficiency anemia, aplastic anemia, sickle cell disease, and hemophilia. Review articles and book chapters pertaining to the care and treatment of children with hematologic disorders. These common hematologic disorders of childhood have the potential to cause not only acute illness but chronic medical problems, particularly in the growing child. Anticipating and preventing the long-term effects of the illness and treatment are the primary goals of care. Nursing assessment, patient education, and long-term follow-up are major factors in the care of children with hematologic disorders. Nurse-managed comprehensive care clinics have provided successful programs directed at acute care and maintenance care for these children and their families.
Sykes, John M; Klaphake, Eric
2015-09-01
The basic principles of hematology used in mammalian medicine can be applied to reptiles. The appearances of the blood cells are significantly different from those seen in most mammals, and vary with taxa and staining method used. Many causes for abnormalities of the reptilian hemogram are similar to those for mammals, although additional factors such as venipuncture site, season, hibernation status, captivity status, and environmental factors can also affect values, making interpretation of hematologic results challenging. Values in an individual should be compared with reference ranges specific to that species, gender, and environmental conditions when available. Copyright © 2015 Elsevier Inc. All rights reserved.
Relapsing Fever: Diagnosis Thanks to a Vigilant Hematology Laboratory.
Fuchs, Inbal; Tarabin, Salman; Kafka, Michael
2015-07-01
Three cases of relapsing fever from southern Israel were diagnosed promptly thanks to vigilance of the hematology laboratory technicians. In this region of Israel, patients presenting with prolonged fever and leukopenia without localizing symptoms are generally suspected of having brucellosis or a rickettsial disease. Pediatric patients with prolonged fever, cytopenias, and negative aforementioned serologies are often hospitalized for further work-up. Because of the policy of performing a manual blood smear when results of the automated blood count demonstrate severe anemia and abnormal platelet and/or white blood cell counts, a diagnosis of tick-borne relapsing fever was confirmed and promptly relayed to the physician. This routine prevented unnecessary examinations and hospitalization days and provided important information to regional epidemiology and public health authorities.
NASA Astrophysics Data System (ADS)
Nickerson, Nick; Kim-Hak, David; McArthur, Gordon
2017-04-01
Preservation and restoration of wetlands has the potential to help sequester large amounts of carbon due to the naturally high primary productivity and slow turnover of stored soil carbon. However, the anoxic environmental conditions present in wetland soils are also the largest natural contributor to global methane emissions. While it is well known that wetlands are net carbon sinks over long time scales, given the high global warming potential of methane, the short-term balances between C uptake and storage and loss as CO2 and CH4 need to be carefully considered when evaluating the climate effects of land-use change. It is relatively difficult to measure methane emissions from wetlands with currently available techniques given the temporally and spatially sporadic nature of the processes involved (methanogenesis, methane oxidation, ebullition, etc.). For example, using manual soil flux chambers can often only capture a portion of either the spatial or temporal variability, and often have other disadvantages associated with soil atmosphere disturbance during deployment in these relatively compressible wetland soils. Automated chamber systems offer the advantage of collecting high-resolution time series of gaseous fluxes while reducing some human and method induced biases. Additionally, new laser-based analyzers that can be used in situ alongside automated chambers offer a greater minimum detectable flux than can be achieved using alternative methods such as Gas Chromatography. Until recently these types of automated measurements were limited to areas that had good power coverage, as laser based systems were power intensive and could not easily be supplemented with power from field-available sources such as solar. Recent advances in laser technology has reduced the power needed and made these systems less power intensive and more field portable in the process. Here we present data using an automated chamber system coupled to a portable laser based greenhouse gas
21 CFR 864.8625 - Hematology quality control mixture.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hematology quality control mixture. 864.8625 Section 864.8625 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8625 Hematology...
21 CFR 864.8625 - Hematology quality control mixture.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hematology quality control mixture. 864.8625 Section 864.8625 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8625 Hematology...
21 CFR 864.8625 - Hematology quality control mixture.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hematology quality control mixture. 864.8625 Section 864.8625 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8625 Hematology...
Aviation Safety: Modeling and Analyzing Complex Interactions between Humans and Automated Systems
NASA Technical Reports Server (NTRS)
Rungta, Neha; Brat, Guillaume; Clancey, William J.; Linde, Charlotte; Raimondi, Franco; Seah, Chin; Shafto, Michael
2013-01-01
The on-going transformation from the current US Air Traffic System (ATS) to the Next Generation Air Traffic System (NextGen) will force the introduction of new automated systems and most likely will cause automation to migrate from ground to air. This will yield new function allocations between humans and automation and therefore change the roles and responsibilities in the ATS. Yet, safety in NextGen is required to be at least as good as in the current system. We therefore need techniques to evaluate the safety of the interactions between humans and automation. We think that current human factor studies and simulation-based techniques will fall short in front of the ATS complexity, and that we need to add more automated techniques to simulations, such as model checking, which offers exhaustive coverage of the non-deterministic behaviors in nominal and off-nominal scenarios. In this work, we present a verification approach based both on simulations and on model checking for evaluating the roles and responsibilities of humans and automation. Models are created using Brahms (a multi-agent framework) and we show that the traditional Brahms simulations can be integrated with automated exploration techniques based on model checking, thus offering a complete exploration of the behavioral space of the scenario. Our formal analysis supports the notion of beliefs and probabilities to reason about human behavior. We demonstrate the technique with the Ueberligen accident since it exemplifies authority problems when receiving conflicting advices from human and automated systems.
Pilot study analyzing automated ECG screening of hypertrophic cardiomyopathy.
Campbell, Matthew J; Zhou, Xuefu; Han, Chia; Abrishami, Hedayat; Webster, Gregory; Miyake, Christina Y; Sower, Christopher T; Anderson, Jeffrey B; Knilans, Timothy K; Czosek, Richard J
2017-06-01
Hypertrophic cardiomyopathy (HCM) is one of the leading causes of sudden cardiac death in athletes. However, preparticipation ECG screening has often been criticized for failing to meet cost-effectiveness thresholds, in part because of high false-positive rates and the cost of ECG screening itself. The purpose of this study was to assess the testing characteristics of an automated ECG algorithm designed to screen for HCM in a multi-institutional pediatric cohort. ECGs from patients with HCM aged 12 to 20 years from 3 pediatric institutions were screened for ECG criteria for HCM using a previously described automated computer algorithm developed specifically for HCM ECG screening. The results were compared to a known healthy pediatric cohort. The studies then were read by trained electrophysiologists using standard ECG criteria and compared to the results of automated screening. One hundred twenty-eight ECGs from unique patients with phenotypic HCM were obtained and compared with 256 studies from healthy control patients matched in 2:1 fashion. When presented with the ECGs, the non-voltage-based algorithm resulted in 81.2% sensitivity and 90.7% specificity. A trained electrophysiologist read the same data according to the Seattle Criteria, with 71% sensitivity with 95.7% specificity. The sensitivity of screening as well as the components of the ECG screening itself varied by institution. This pilot study demonstrates a potential for automated ECG screening algorithms to detect HCM with testing characteristics similar to that of a trained electrophysiologist. In addition, there appear to be differences in ECG characteristics between patient populations, which may account for the difficulties in universal screening. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
[Testing the hemalog D in a hematology department of a general hospital in Paris (author's transl)].
Lortholary, P; Lejeune, F; Ganon, J P; Mathiot, C; Turpin, F
1978-06-10
Europe's firs Hemalog D was installed in the Hematology Laboratory of the Franco-Musulman Hospital at Bobigny, just outside Paris, in March 1975. The authors' experience with the apparatus since that date has enabled them to analyze the significance of "alarms", "high peroxidase", "large unstained cells", "remainder" and "low rate" in patients with and without hematologic disorders. On the basis of these results it has been possible to define the fate of the various blood cells in the Hemalog D, the role of the apparatus in the ivestigation of hematologic disorders and the type of "cooperation" between the hematologist and the Hemalog D.
American Society of Pediatric Hematology/Oncology
... Learn More Explore career opportunities in pediatric hematology/oncology Visit the ASPHO Career Center. Learn More Join ... Privacy Policy » © The American Society of Pediatric Hematology/Oncology
Lee, Sungsil; Lim, Hwan Sub; Park, Jungyong; Kim, Hyon Suk
2009-04-01
In the diagnosis of atopic diseases, allergen detection is a crucial step. Multiple allergen simultaneous test-chemiluminescent assay (MAST-CLA) is a simple and noninvasive method for in vitro screening of allergen-specific IgE antibodies. The Korean Inhalant Panel test on 20 patients and Food Panel test on 19 patients were performed using the conventional manual MAST-CLA kit and the new automated MAST-CLA method (automated AP720S system for the Optigen Assay; Hitachi Chemical Diagnostics, Inc., USA) simultaneously. The results were evaluated for positive reactivity and concordance. The results of inhalant panel gave a relatively higher class level result than the food panel. The 8 patients out of 20 (40%) of the inhalation panel, and 9 patients out of 18 (47.4%) of the food panel showed 100% concordance between the 2 systems. Eighteen patients (90%) of the Inhalation Panel and sixteen patients (84.2%) of the Food Panel showed more than 91% concordance. These results suggest that the MAST-CLA assay using the new, automated AP720S analyzer performs well, showing a high concordance rate with conventional MAST-CLA. Compared to manual MAST-CLA, the automated AP720S system has a shorter assay time and uses a smaller serum volume (500 microl) along with other conveniences.
Hematologic Complications of Pregnancy
Townsley, Danielle M.
2013-01-01
Pregnancy induces a number of physiologic changes that affect the hematologic indices, either directly or indirectly. Recognizing and treating hematologic disorders that occur during pregnancy is difficult owing to the paucity of evidence available to guide consultants. This paper specifically reviews the diagnosis and management of benign hematologic disorders occurring during pregnancy. Anemia secondary to iron deficiency is the most frequent hematologic complication and is easily treated with oral iron formulations,; however care must be taken not to miss other causes of anemia, such as sickle cell disease. Thrombocytopenia is also a common reason for consulting the hematologist and distinguishing gestational thrombocytopenia from immune thrombocytopenia (ITP), preeclampsia, HELLP syndrome, or thrombotic thrombocytopenic purpura (TTP) is essential since the treatment differs widely. Occasionally the management of mother and infant involves the expeditious recognition of neonatal alloimmune thrombocytopenia (NAIT), a condition that is responsible for severe life-threatening bleeding of the newborn. Additionally, inherited and acquired bleeding disorders affect pregnant women disproportionately and often require careful monitoring of coagulation parameters in order to prevent bleeding in the puerperium. Finally, venous thromboembolism (VTE) during pregnancy is still largely responsible for mortality during pregnancy and the diagnosis, treatment options and guidelines for prevention of VTE during pregnancy are explored. PMID:23953339
Hematologic complications of pregnancy.
Townsley, Danielle M
2013-07-01
Pregnancy induces a number of physiologic changes that affect the hematologic indices, either directly or indirectly. Recognizing and treating hematologic disorders that occur during pregnancy is difficult owing to the paucity of evidence available to guide consultants. This review discusses specifically the diagnosis and management of benign hematologic disorders occurring during pregnancy. Anemia secondary to iron deficiency is the most frequent hematologic complication and is easily treated with oral iron formulations; however, care must be taken not to miss other causes of anemia, such as sickle cell disease. Thrombocytopenia is also a common reason for consulting the hematologist, and distinguishing gestational thrombocytopenia from immune thrombocytopenia (ITP), preeclampsia, HELLP syndrome (hemolysis, elevated liver enzymes, and low platelets), or thrombotic thrombocytopenic purpura (TTP) is essential since the treatment differs widely. Occasionally the management of mother and infant involves the expeditious recognition of neonatal alloimmune thrombocytopenia (NAIT), a condition that is responsible for severe life-threatening bleeding of the newborn. Additionally, inherited and acquired bleeding disorders affect pregnant women disproportionately and often require careful monitoring of coagulation parameters to prevent bleeding in the puerperium. Finally, venous thromboembolism (VTE) during pregnancy is still largely responsible for mortality during pregnancy, and the diagnosis, treatment options and guidelines for prevention of VTE during pregnancy are explored. Published by Elsevier Inc.
Vitamin e supplementation with rauwolfia vomitoria root bark extract improves hematological indices.
Isaiah, Akpanabiatu Monday; Olawale, Otitoju; Effiong, Edet Emmanuel; Idongesit, Ndem Jessie; Fidelis, Uwah Anthony; Friday, Ufot Usenobong
2012-02-01
Vitamin supplementation in Rauwolfia vomitoria root bark extract administration may interact and impact significantly on hematology of albino Wistar rats. In this investigation we studied vitamin E supplementation with Rauwolfia vomitoria root bark extract on the hematology of experimental animals. Forty two rats weighing 200 - 230 g were randomly selected into six groups of seven animals each. Group 1 animals serve as controls; group 2 received vitamin E (10 IU/kg body weight). Groups 3 and 4 were given the extract (150 and 300 mg/kg body weight) respectively. Groups 5 and 6 were given vitamin E (10 IU/kg body weight), the extract (150 and 300 mg/kg body weight) respectively. The extract and the vitamin were administered daily by oral intubation. Blood samples analyzed for hematological indices. Decrease in white blood cell count (WBC) was observed, indicating improved immunity of animals. Extract at 150 and 300 mg/kg body weight with and without vitamin E affected hemoglobin and packed cell volume. Rauwolfia vomitoria with or without vitamin E improved animal's immunity and enhances their hematology. Interaction of vitamin E with the extract affects medicinal therapeutics of this plant.
Ataro, Zerihun; Geremew, Abraham; Urgessa, Fekadu
2018-01-01
Occupational exposure to chemicals in garages causes a wide range of biological effects, depending upon the level and duration of exposure. In Ethiopia, there have been few studies conducted to assess the exposure of garage workers to chemicals. Preceding studies have not explored the effect of working in garage on blood pressure and hematological parameters. Therefore, this study aimed to assess differences in blood pressure and hematological parameters among garage workers compared to the Haramaya University community, Harar, eastern Ethiopia. A comparative cross-sectional study was conducted in Harar town, eastern Ethiopia. Thirty garage workers were selected and compared with 30 age- and sex-matched controls comprising of teachers and students. Demographic and occupational data were collected by using a structured questionnaire by a trained data collector. Blood pressure was measured using sphygmomanometry. Hematological parameters were measured with an automated hematology analyzer. Data were analyzed using Stata version 13. The majority of the garage workers did not implement effective preventive or control measures for workplace chemical exposure. Statistically significant increases were found in systolic (128.67±18.14 vs 106.33 ±9.27 mmHg, P <0.0001), diastolic blood pressure (90.33±11.29 vs 75.67 ±5.68 mmHg, P <0.0001), total white blood cells (7.9±1.51 vs 6.72±2.04×10 9 cells/L, P =0.0138), and platelets (323.20±48.82 vs 244.1±47.3×10 9 cells/L, P <0.0001) in garage workers compared to the control group. On the other hand, statistically significant decreases were found in red blood cells (5.13±0.38 vs 5.46±0.36×10 12 cells/L, P =0.0006), hemoglobin (14.89±0.71 vs 15.45±0.87 g/dL, P =0.0062), hematocrit (43.98%±1.99% vs 46.4%3±2.32%, P <0.0001), and mean corpuscular volume (83.19±2.93 vs 85.11±3.87 fL, P =0.0353) among garage workers compared to the control group. There were significant differences in blood pressure and hematological
Ataro, Zerihun; Geremew, Abraham; Urgessa, Fekadu
2018-01-01
Background Occupational exposure to chemicals in garages causes a wide range of biological effects, depending upon the level and duration of exposure. In Ethiopia, there have been few studies conducted to assess the exposure of garage workers to chemicals. Preceding studies have not explored the effect of working in garage on blood pressure and hematological parameters. Therefore, this study aimed to assess differences in blood pressure and hematological parameters among garage workers compared to the Haramaya University community, Harar, eastern Ethiopia. Materials and methods A comparative cross-sectional study was conducted in Harar town, eastern Ethiopia. Thirty garage workers were selected and compared with 30 age- and sex-matched controls comprising of teachers and students. Demographic and occupational data were collected by using a structured questionnaire by a trained data collector. Blood pressure was measured using sphygmomanometry. Hematological parameters were measured with an automated hematology analyzer. Data were analyzed using Stata version 13. Results The majority of the garage workers did not implement effective preventive or control measures for workplace chemical exposure. Statistically significant increases were found in systolic (128.67±18.14 vs 106.33 ±9.27 mmHg, P<0.0001), diastolic blood pressure (90.33±11.29 vs 75.67 ±5.68 mmHg, P<0.0001), total white blood cells (7.9±1.51 vs 6.72±2.04×109 cells/L, P=0.0138), and platelets (323.20±48.82 vs 244.1±47.3×109 cells/L, P<0.0001) in garage workers compared to the control group. On the other hand, statistically significant decreases were found in red blood cells (5.13±0.38 vs 5.46±0.36×1012 cells/L, P=0.0006), hemoglobin (14.89±0.71 vs 15.45±0.87 g/dL, P=0.0062), hematocrit (43.98%±1.99% vs 46.4%3±2.32%, P<0.0001), and mean corpuscular volume (83.19±2.93 vs 85.11±3.87 fL, P=0.0353) among garage workers compared to the control group. Conclusion There were significant
Automated system for analyzing the activity of individual neurons
NASA Technical Reports Server (NTRS)
Bankman, Isaac N.; Johnson, Kenneth O.; Menkes, Alex M.; Diamond, Steve D.; Oshaughnessy, David M.
1993-01-01
This paper presents a signal processing system that: (1) provides an efficient and reliable instrument for investigating the activity of neuronal assemblies in the brain; and (2) demonstrates the feasibility of generating the command signals of prostheses using the activity of relevant neurons in disabled subjects. The system operates online, in a fully automated manner and can recognize the transient waveforms of several neurons in extracellular neurophysiological recordings. Optimal algorithms for detection, classification, and resolution of overlapping waveforms are developed and evaluated. Full automation is made possible by an algorithm that can set appropriate decision thresholds and an algorithm that can generate templates on-line. The system is implemented with a fast IBM PC compatible processor board that allows on-line operation.
... of ASH educational meetings and webinars ASH Image Bank Educational Web-based library of hematologic imagery ... quickly allogeneic: refers to blood, stem cells, bone marrow, or other tissue that is transferred from one person to another ...
[Hematologic malignancies in pregnancy].
Doubek, R; Petrovová, D; Kalvodová, J; Doubek, M
2009-04-01
To summarize available data concerning hematologic malignancies in pregnancy. Review article. Department of Obstetrics and Gynekology, Fakulty of Medicine, Masaryk University and University Hospital Brno. Compilation of published data from scientific literature. Cancer complicating pregnancy is a rare coexistence. The incidence is approximately 1 in 1,000 pregnancies. The most frequent hematologic malignant tumor is Hodgkin's lymphoma, leukemia is less frequent and myeloproliferative diseases complicating pregnancy are sporadic coexistence. Symptoms of these deseases are often nonspecific and disguised in pregnancy, then the diagnosis can be late. It is imperative that a multidisciplinary team involving hematooncologist and obstetrician (pediatric specialist) care for patient with hematologic malignancies. Cleary, every patient have to know whole prognosis and all risk factors of treatment. Optimum timing of delivery is after 36th week of pregnancy (when chemotherapy is ended more than two weeks ago). We prefer vaginal delivery to caesarean section.
Neural-network-based state of health diagnostics for an automated radioxenon sampler/analyzer
NASA Astrophysics Data System (ADS)
Keller, Paul E.; Kangas, Lars J.; Hayes, James C.; Schrom, Brian T.; Suarez, Reynold; Hubbard, Charles W.; Heimbigner, Tom R.; McIntyre, Justin I.
2009-05-01
Artificial neural networks (ANNs) are used to determine the state-of-health (SOH) of the Automated Radioxenon Analyzer/Sampler (ARSA). ARSA is a gas collection and analysis system used for non-proliferation monitoring in detecting radioxenon released during nuclear tests. SOH diagnostics are important for automated, unmanned sensing systems so that remote detection and identification of problems can be made without onsite staff. Both recurrent and feed-forward ANNs are presented. The recurrent ANN is trained to predict sensor values based on current valve states, which control air flow, so that with only valve states the normal SOH sensor values can be predicted. Deviation between modeled value and actual is an indication of a potential problem. The feed-forward ANN acts as a nonlinear version of principal components analysis (PCA) and is trained to replicate the normal SOH sensor values. Because of ARSA's complexity, this nonlinear PCA is better able to capture the relationships among the sensors than standard linear PCA and is applicable to both sensor validation and recognizing off-normal operating conditions. Both models provide valuable information to detect impending malfunctions before they occur to avoid unscheduled shutdown. Finally, the ability of ANN methods to predict the system state is presented.
Rossi, Gabriele; Mangiagalli, Gerard; Paracchini, Giulia; Paltrinieri, Saverio
2014-03-01
Information about laboratory reference intervals (RIs) of European Hedgehog (Erinaceus europaeus) hospitalized at rehabilitation centers is scarce. The purpose of this study was to establish hematologic and biochemical RIs for rehabilitated hedgehogs before the release into the wild, and to assess whether sex and management of the center influence laboratory results. Blood was collected from 50 hedgehogs at 3 centers. Thirty-eight animals were included in the study based on normal body weight, absence of clinical signs of disease, Bunnell index > 0.80, and absence of hibernation during overwintering. CBCs were performed using an automated laser cell counter followed by morphologic analysis of blood smears. Clinical biochemistry was performed using an automated spectrophotometer. RIs were determined as recommended by the ASVCP guidelines. Hematology profiles revealed a prevalence of lymphocytes, a constant presence of nucleated RBCs, Howell-Jolly bodies and basophils, and bilobed nuclei in neutrophils and eosinophils. Biochemistry profiles were characterized by higher creatinine and urea concentrations, and higher ALP and GGT activities compared with other domestic species. The sex did not influence the results. Conversely, numbers of eosinophils, activated and large granular lymphocytes, and concentrations of total protein, glucose and cholesterol were different among the centers, likely due to different management practices (eg, antiparasitic treatments, environmental exposure to microorganisms, diet). The RIs established in this study can be used to monitor the health status of hedgehogs in rehabilitation centers. As management practices appeared to influence some variables, it is recommended to standardize the management protocols to minimize their influence on laboratory data. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.
Catheter-associated bloodstream infections in pediatric hematology-oncology patients.
Celebi, Solmaz; Sezgin, Melike Evim; Cakır, Deniz; Baytan, Birol; Demirkaya, Metin; Sevinir, Betul; Bozdemir, Sefika Elmas; Gunes, Adalet Meral; Hacimustafaoglu, Mustafa
2013-04-01
Catheter-associated bloodstream infections (CABSIs) are common complications encountered with cancer treatment. The aims of this study were to analyze the factors associated with recurrent infection and catheter removal in pediatric hematology-oncology patients. All cases of CABSIs in patients attending the Department of Pediatric Hematology-Oncology between January 2008 and December 2010 were reviewed. A total of 44 episodes of CABSIs, including multiple episodes involving the same catheter, were identified in 31 children with cancer. The overall CABSIs rate was 7.4 infections per 1000 central venous catheter (CVC) days. The most frequent organism isolated was coagulase-negative Staphylococcus (CONS). The CVC was removed in nine (20.4%) episodes. We found that hypotension, persistent bacteremia, Candida infection, exit-side infection, neutropenia, and prolonged duration of neutropenia were the factors for catheter removal. There were 23 (52.2%) episodes of recurrence or reinfection. Mortality rate was found to be 9.6% in children with CABSIs. In this study, we found that CABSIs rate was 7.4 infections per 1000 catheter-days. CABSIs rates in our hematology-oncology patients are comparable to prior reports. Because CONS is the most common isolated microorganism in CABSIs, vancomycin can be considered part of the initial empirical regimen.
Gaspar-López, Enrique; Landete-Castillejos, Tomás; Estevez, Jose Antonio; Ceacero, Francisco; Gallego, Laureano; García, Andrés Jose
2011-04-01
The aim of the study was to relate seasonal hematology changes with the rest of physiological variations suffered by red deer, such as antler and biometrics cycle, and to assess the relationship between hematology and the effort performed in antler development. Blood samples were taken from 21 male red deer every 4 weeks during 18 months. Samples were analyzed for the main hematological parameters. Simultaneously, biometrics measurements were taken, such as antler length, body weight, body condition score, testicular diameter (TD), and thoracic and neck girth. All the blood cell types (erythrocytes, leukocytes, and platelets) showed seasonal variations, increasing as antler cleaning approached, as did hematocrit and hemoglobin. The final size of antlers was negatively related to leukocyte count, nonlymphoid leukocyte count, red cell distribution width, mean corpuscular hemoglobin, mean platelet volume, and TD, whereas it was positively related to body condition during antler growth. Huge seasonal variations in some hematological values have been found to be related to changes in antler and biometrics measurements. Since these variations are even greater than the caused by deer handling, they should be taken into account when evaluating hematology in deer populations. Copyright © 2011 Wiley-Liss, Inc., A Wiley Company.
Challenges to laboratory hematology practice: Egypt perspective.
Rizk, S H
2018-05-01
Laboratory hematology is an integral part of all clinical laboratories along the extensive healthcare facilities in Egypt. The aim of this review is to portrait the laboratory hematology practice in Egypt including its unique socioeconomic background, blood disease pattern, education and training, regulatory oversight, and the related challenges. Current practice varies widely between different parts of the healthcare system in terms of the range of tests, applied techniques, workforce experience, and quality of service. The national transfusion service (NBTS) in Egypt has been recently upgraded and standardized according to the World Health Organization (WHO) guidelines. Formal postgraduate education roughly follows the British system. Laboratory hematology specialization is achieved through 2-3 years masters' degree followed by 2-4 years doctorate degree in clinical pathology with training and research in hematology. Improvement of laboratory hematology education is recently undergoing a reform as a part of the modernization of higher education policy and following the standards developed by the National Quality Assurance and Accreditation Agency (NQAAA). Accreditation of medical laboratories is recently progressing with the development of the "Egyptian Accreditation Council" (EGAC) as the sole accreditation body system and training of assessors. Current laboratory system has many challenges, some are related to the inadequate system performance, and others are unique to laboratory hematology issues. The rapid technological advances and therapeutic innovations in hematology practice call for an adapting laboratory system with continuous upgrading. © 2018 John Wiley & Sons Ltd.
Vitamin E Supplementation with Rauwolfia Vomitoria Root Bark Extract Improves Hematological Indices
Isaiah, Akpanabiatu Monday; Olawale, Otitoju; Effiong, Edet Emmanuel; Idongesit, Ndem Jessie; Fidelis, Uwah Anthony; Friday, Ufot Usenobong
2012-01-01
Background: Vitamin supplementation in Rauwolfia vomitoria root bark extract administration may interact and impact significantly on hematology of albino Wistar rats. Aim: In this investigation we studied vitamin E supplementation with Rauwolfia vomitoria root bark extract on the hematology of experimental animals. Materials and Methods: Forty two rats weighing 200 – 230 g were randomly selected into six groups of seven animals each. Group 1 animals serve as controls; group 2 received vitamin E (10 IU/kg body weight). Groups 3 and 4 were given the extract (150 and 300 mg/kg body weight) respectively. Groups 5 and 6 were given vitamin E (10 IU/kg body weight), the extract (150 and 300 mg/kg body weight) respectively. The extract and the vitamin were administered daily by oral intubation. Blood samples analyzed for hematological indices. Results: Decrease in white blood cell count (WBC) was observed, indicating improved immunity of animals. Extract at 150 and 300 mg/kg body weight with and without vitamin E affected hemoglobin and packed cell volume. Conclusion: Rauwolfia vomitoria with or without vitamin E improved animal's immunity and enhances their hematology. Interaction of vitamin E with the extract affects medicinal therapeutics of this plant. PMID:22408754
A method to identify and analyze biological programs through automated reasoning
Yordanov, Boyan; Dunn, Sara-Jane; Kugler, Hillel; Smith, Austin; Martello, Graziano; Emmott, Stephen
2016-01-01
Predictive biology is elusive because rigorous, data-constrained, mechanistic models of complex biological systems are difficult to derive and validate. Current approaches tend to construct and examine static interaction network models, which are descriptively rich, but often lack explanatory and predictive power, or dynamic models that can be simulated to reproduce known behavior. However, in such approaches implicit assumptions are introduced as typically only one mechanism is considered, and exhaustively investigating all scenarios is impractical using simulation. To address these limitations, we present a methodology based on automated formal reasoning, which permits the synthesis and analysis of the complete set of logical models consistent with experimental observations. We test hypotheses against all candidate models, and remove the need for simulation by characterizing and simultaneously analyzing all mechanistic explanations of observed behavior. Our methodology transforms knowledge of complex biological processes from sets of possible interactions and experimental observations to precise, predictive biological programs governing cell function. PMID:27668090
Park, Sang Hyuk; Park, Chan-Jeoung; Kim, Mi-Jeong; Choi, Mi-Ok; Han, Min-Young; Cho, Young-Uk; Jang, Seongsoo
2014-12-01
We developed and validated an interinstrument comparison method for automatic hematology analyzers based on the 99th percentile coefficient of variation (CV) cutoff of daily means and validated in both patient samples and quality control (QC) materials. A total of 120 patient samples were obtained over 6 months. Data from the first 3 months were used to determine 99th percentile CV cutoff values, and data obtained in the last 3 months were used to calculate acceptable ranges and rejection rates. Identical analyses were also performed using QC materials. Two instrument comparisons were also performed, and the most appropriate allowable total error (ATE) values were determined. The rejection rates based on the 99th percentile cutoff values were within 10.00% and 9.30% for the patient samples and QC materials, respectively. The acceptable ranges of QC materials based on the currently used method were wider than those calculated from the 99th percentile CV cutoff values in most items. In two-instrument comparisons, 34.8% of all comparisons failed, and 87.0% of failed comparisons were successful when 4 SD was applied as an ATE value instead of 3 SD. The 99th percentile CV cutoff value-derived daily acceptable ranges can be used as a real-time interinstrument comparison method in both patient samples and QC materials. Applying 4 SD as an ATE value can significantly reduce unnecessarily followed recalibration in the leukocyte differential counts, reticulocytes, and mean corpuscular volume. Copyright© by the American Society for Clinical Pathology.
NASA Astrophysics Data System (ADS)
Chiesl, T. N.; Benhabib, M.; Stockton, A. M.; Mathies, R. A.
2010-04-01
We present the Multichannel Mars Organic Analyzer (McMOA) for the analysis of Amino Acids, PAHs, and Oxidized Carbon. Microfluidic architecures integrating automated metering, mixing, on chip reactions, and serial dilutions are also discussed.
Ramchandren, Radhakrishnan; Schiffer, Charles A
2016-03-01
The major large US hematology-oncology meetings sponsored by the American Society of Hematology (ASH) and American Society of Clinical Oncology (ASCO) have specific guidelines in place discouraging submission of scientific information presented previously at other meetings. Nonetheless, duplicate submissions are frequent. The incidence and motivations for duplicate hematologic presentations and the influence of the pharmaceutical industry on this process have not been thoroughly analyzed. Therefore, were viewed four consecutive ASH and ASCO meetings to assess the frequency of duplicate abstract presentations. All abstracts presented at ASCO2010 in the area of malignant hematology were compared with abstracts from ASCO and ASH 2009 and ASH 2010, and funding sources were reviewed. More than half (54%) of all abstracts submitted to ASCO 2010 acknowledged pharmaceutical company support. Almost one third (31%) of ASCO 2010 abstracts were resubmitted in the 2-year time period, and it was notable that a high fraction (75%) of these duplicate abstracts had pharmaceutical industry sponsorship, compared with 42% of the abstracts that were submitted only once. Despite current guidelines prohibiting duplicate abstract presentation, a substantial proportion (31%) of abstracts at large international hematology-oncology meetings are duplicative, with potential negative consequences. In addition, a disproportionate percentage of the duplicate abstracts rely on pharmaceutical industry support (75%), suggesting that marketing strategies may be a motivation for some of these repetitive submissions.
Work, T M
1999-03-01
Hematologic and serum chemistry values are reported for 105 brown boobies (Sula leucogaster) from Johnston Atoll, Central Pacific. Hematocrit, estimated total plasma solids, total and differential white cell counts, serum glucose, calcium, phosphorus, uric acid, total protein, albumin, globulin, aspartate aminotransferase, and creatinine phosphokinase were analyzed. Hematologic and serum chemistry values varied with age and sex. Values were compared with those of red-footed boobies and other tropical and temperate marine pelecaniforms.
Work, Thierry M.
1999-01-01
Hematologic and serum chemistry values are reported for 105 brown boobies (Sula leucogaster) from Johnston Atoll, Central Pacific. Hematocrit, estimated total plasma solids, total and differential white cell counts, serum glucose, calcium, phosphorus, uric acid, total protein, albumin, globulin, aspartate aminotransferase, and creatinine phosphokinase were analyzed. Hematologic and serum chemistry values varied with age and sex. Values were compared with those of red-footed boobies and other tropical and temperate marine pelecaniforms.
Ahmed, Idris Adewale; Mikail, Maryam Abimbola; Ibrahim, Muhammad
2017-06-01
Hypercholesterolemia is an important risk factor linked to the alteration of blood hematology and clinical chemistry associated with the development and progression of atherosclerosis. Previous studies have demonstrated the safety and potential health benefits of Baccaurea angulata (BA) fruit. We hypothesized that the oral administration of BA fruit juice could ameliorate the alteration in the hematological and biochemical biomarkers of diet-induced hypercholesterolemic rabbits. The aim of this study was to investigate the effects of different doses of BA juice on the hematological and biochemical biomarkers in normo- and hypercholesterolemic rabbits. Thirty-five healthy adult New Zealand White rabbits were assigned to seven different groups for 90days of diet intervention. Four atherogenic groups were fed a 1% cholesterol diet and 0, 0.5, 1.0, and 1.5mL of BA juice per kg of rabbit daily. The other three normal groups were fed a commercial rabbit pellet diet and 0, 0.5, and 1.0mL of BA juice per kg of rabbit daily. Baseline and final blood samples after 90days of repeated administration BA juice were analyzed for hematological parameters while serum, aortic and hepatic lysates were analyzed for lipid profiles and other biochemical biomarkers. The alteration of the hemopoietic system, physiological changes in serum and tissues lipid profiles and other biochemicals resulting from the consumption of a high-cholesterol diet were significantly (P<.05) ameliorated by the administration of BA juice. Improvements of the biomarkers in rabbits were dose-dependent, markedly enhanced at the highest dose of juice (1.5mL/kg/day). The results suggest potential health benefits of the antioxidant-rich BA fruit juice against hypercholesterolemia-associated hematological and biochemical alterations in the rabbit. Copyright © 2017 Elsevier Inc. All rights reserved.
Ventilatory support in critically ill hematology patients with respiratory failure
2012-01-01
Introduction Hematology patients admitted to the ICU frequently experience respiratory failure and require mechanical ventilation. Noninvasive mechanical ventilation (NIMV) may decrease the risk of intubation, but NIMV failure poses its own risks. Methods To establish the impact of ventilatory management and NIMV failure on outcome, data from a prospective, multicenter, observational study were analyzed. All hematology patients admitted to one of the 34 participating ICUs in a 17-month period were followed up. Data on demographics, diagnosis, severity, organ failure, and supportive therapies were recorded. A logistic regression analysis was done to evaluate the risk factors associated with death and NIVM failure. Results Of 450 patients, 300 required ventilatory support. A diagnosis of congestive heart failure and the initial use of NIMV significantly improved survival, whereas APACHE II score, allogeneic transplantation, and NIMV failure increased the risk of death. The risk factors associated with NIMV success were age, congestive heart failure, and bacteremia. Patients with NIMV failure experienced a more severe respiratory impairment than did those electively intubated. Conclusions NIMV improves the outcome of hematology patients with respiratory insufficiency, but NIMV failure may have the opposite effect. A careful selection of patients with rapidly reversible causes of respiratory failure may increase NIMV success. PMID:22827955
Lipid and hematological parameters in hyperleptinemic healthy Arab male youth in Jordan.
Abu-Samak, Mahmoud; Yousef, Al-Motassem; Al-Jarie, Ahmad; Al-Matubsi, Hisham Y; Abu-Zaiton, Ahmed; Al-Quraan, Mamoun; Khuzaie, Rula
2011-03-01
To analyze the influence ofhyperleptinemia on fasting lipid and hematological parameters in healthy Arab male youth in Jordan, this cross-sectional study was carried out in April 2009 on a sample of 120 students aged 18-24 years. Subjects were stratified by fasting leptin into two groups (control, <12.7 ng mL(-1) vs. hyperleptenimic, e_< 12.7 ng mL(-1)) and BMI (normal weight, < 25 kgm(-2) vs. overweight/obese, BMI e_< 25 kg m(-2)). Fasting serum leptin, blood glucose, lipid profile and hematological parameters values were determined by standard kit methods. Mean serum leptin concentrations were more than five times as high in hyperleptenemic subjects than in control subjects (p < 0.001). Compared with control group, significant elevations (p < 0.01) were observed in the means total cholesterol, LDL cholesterol and triglyceride levels of hyperleptenemic group whereas no significant differences was detected in HDL-cholesterol. Except the changes of WBC count, MCH and slightly MCHC, there were no differences between both groups in any other term of hematological parameters. In conclusion, changes in lipid variables and some hematological parameters may increase plasma viscosity as a step during atherosclerosis pathogenesis in male youth at risk for dyslipidemia and cardiovascular diseases. Thus, hyperleptinemia could be a useful index in identifying healthy youth male subjects but this hypothesis needs further investigation.
Eosinophilic Dermatosis of Hematologic Malignancy.
Lucas-Truyols, S; Rodrigo-Nicolás, B; Lloret-Ruiz, C; Quecedo-Estébanez, E
Dermatosis characterized by tissue eosinophilia arising in the context of hematologic disease is known as eosinophilic dermatosis of hematologic malignancy. The most commonly associated malignancy is chronic lymphocytic leukemia. Eosinophilic dermatosis of hematologic malignancy is a rare condition with a wide variety of clinical presentations, ranging from papules, erythematous nodules, or blisters that simulate arthropod bites, to the formation of true plaques of differing sizes. Histology reveals the presence of abundant eosinophils. We present 4 new cases seen in Hospital Arnau de Vilanova, Valencia, during the past 7 years. Three of these cases were associated with chronic lymphocytic leukemia and 1 with mycosis fungoides. It is important to recognize this dermatosis as it can indicate progression of the underlying disease, as was the case in 3 of our patients. Copyright © 2017 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.
Comparative veterinary hematology: a bird's eye view.
Jensen, E C
1981-12-01
A comparative look at veterinary hematology in the class Mammalia is presented to acquaint the medical technologist with a new dimension in clinical pathology. Aspects of clinical hematology, such as erythrocyte and leukocyte morphologies, dynamics, and diseases, are discussed.
Musculoskeletal Imaging Findings of Hematologic Malignancies.
Navarro, Shannon M; Matcuk, George R; Patel, Dakshesh B; Skalski, Matthew; White, Eric A; Tomasian, Anderanik; Schein, Aaron J
2017-01-01
Hematologic malignancies comprise a set of prevalent yet clinically diverse diseases that can affect every organ system. Because blood components originate in bone marrow, it is no surprise that bone marrow is a common location for both primary and metastatic hematologic neoplasms. Findings of hematologic malignancy can be seen with most imaging modalities including radiography, computed tomography (CT), technetium 99m ( 99m Tc) methylene diphosphonate (MDP) bone scanning, fluorine 18 ( 18 F) fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT, and magnetic resonance (MR) imaging. Because of the diversity of imaging appearances and clinical behavior of this spectrum of disease, diagnosis can be challenging, and profound understanding of the underlying pathophysiologic changes and current treatment modalities can be daunting. The appearance of normal bone marrow at MR imaging and FDG PET/CT is also varied due to dynamic compositional changes with normal aging and in response to hematologic demand or treatment, which can lead to false-positive interpretation of imaging studies. In this article, the authors review the normal maturation and imaging appearance of bone marrow. Focusing on lymphoma, leukemia, and multiple myeloma, they present the spectrum of imaging findings of hematologic malignancy affecting the musculoskeletal system and the current imaging tools available to the radiologist. They discuss the imaging findings of posttreatment bone marrow and review commonly used staging systems and consensus recommendations for appropriate imaging for staging, management, and assessment of clinical remission. © RSNA, 2017.
Biermer anemia: Hematologic characteristics of 66 patients in a Clinical Hematology Unit at Senegal.
Seynabou, F; Fatou Samba Diago, N; Oulimata Diop, D; Abibatou Fall, S; Nafissatou, D
2016-11-01
Hematological manifestations can lead to diagnosis of pernicious anemia, also known as Biermer disease and Biermer anemia. This disease has been little studied among black Africans. Our aim is to describe its diagnostic and therapeutic aspects and outcome in our practice. This descriptive study retrospectively examined the records of 66 patients with pernicious anemia seen at the Clinical Hematology Unit of Le Dantec Hospital in Senegal from January 1, 2000, to June 30, 2014. Symptoms were anemic syndrome (40 cases), hemolytic anemia (13), anemic heart failure (7), isolated pallor of the mucous membranes (5), and venous thrombosis (2). Their mean hemoglobin on diagnosis was 6.52 g/dL [1.3-15.2 g/dL], macrocytosis (52), normocytosis (14), hypochromia (4), thrombocytopenia (39), and leukopenia (28 cases). Cytopenia was associated with pancytopenia (25) and bicytopenia (18). Cytologic abnormalities were documented in 42 cases: megaloblastic erythrosis (37 cases) and hypersegmented neutrophils (24 cases). After vitamin B12 therapy - intramuscular (52) or oral (14) -, a reticulocyte crisis was noted on the 8th day and followed by correction of the blood count. Macrocytic anemia, frequently associated with thrombocytopenia and/or leukopenia, is the main hematologic sign evoking pernicious anemia. Venous thrombosis is a rare circumstance of diagnosis that must not be ignored. Intramuscular or oral vitamin B12 is recognized to be effective in these cases and reverses hematological manifestations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoogstraten, B.
1986-01-01
The principle aim of this book is to give practical guidelines to the modern treatment of the six important hematologic malignancies. Topics considered include the treatment of the chronic leukemias; acute leukemia in adults; the myeloproliferative disorders: polycythemia vera, essential thrombocythemia, and idiopathic myelofibrosis/agnogenic myeloid metaplasia; Hodgkin's Disease; non-Hodgkin's lymphoma; and Multiple Myeloma.
Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy
Bakan, Ebubekir; Ozturk, Nurinnisa; Baygutalp, Nurcan Kilic; Polat, Elif; Akpinar, Kadriye; Dorman, Emrullah; Polat, Harun; Bakan, Nuri
2016-01-01
Introduction Urine screening is achieved by either automated or manual microscopic analysis. The aim of the study was to compare Cobas 6500 and Iris IQ200 urine analyzers, and manual urine microscopic analysis. Materials and methods A total of 540 urine samples sent to the laboratory for chemical and sediment analysis were analyzed on Cobas 6500 and Iris IQ200 within 1 hour from sampling. One hundred and fifty three samples were found to have pathological sediment results and were subjected to manual microscopic analysis performed by laboratory staff blinded to the study. Spearman’s and Gamma statistics were used for correlation analyses, and the McNemar test for the comparison of the two automated analyzers. Results The comparison of Cobas u701 to the manual method yielded the following regression equations: y = - 0.12 (95% CI: - 1.09 to 0.67) + 0.78 (95% CI: 0.65 to 0.95) x for WBC and y = 0.06 (95% CI: - 0.09 to 0.25) + 0.66 (95% CI: 0.57 to 0.73) x for RBC. The comparison of IQ200 Elite to manual method the following equations: y = 0.03 (95% CI: - 1.00 to 1.00) + 0.88 (95% CI: 0.66 to 1.00) x for WBC and y = - 0.22 (95% CI: - 0.80 to 0.20) + 0.40 (95% CI: 0.32 to 0.50) x for RBC. IQ200 Elite compared to Cobas u701 yielded the following equations: y = - 0.95 (95% CI: - 2.13 to 0.11) + 1.25 (95% CI: 1.08 to 1.44) x for WBC and y = - 1.20 (95% CI: - 1.80 to -0.30) + 0. 80 (95% CI: 0.55 to 1.00) x for RBC. Conclusions The two analyzers showed similar performances and good compatibility to manual microscopy. However, they are still inadequate in the determination of WBC, RBC, and EC in highly-pathological samples. Thus, confirmation by manual microscopic analysis may be useful. PMID:27812305
Complementary and Alternative Medicine: A Clinical Study in 1,016 Hematology/Oncology Patients.
Hierl, Marina; Pfirstinger, Jochen; Andreesen, Reinhard; Holler, Ernst; Mayer, Stephanie; Wolff, Daniel; Vogelhuber, Martin
2017-01-01
Surveys state a widespread use of complementary and alternative medicine (CAM) in patients with malignant diseases. CAM methods might potentially interfere with the metabolization of tumor-specific therapy. However, there is little communication about CAM use in hematology/oncology patients between patients, CAM providers, and oncologists. A self-administered questionnaire was handed out to all patients attending to the hematology/oncology outpatient clinic of Regensburg University Hospital. Subsequently, a chart review of all CAM users was performed. Questionnaires of 1,016 patients were analyzed. Of these patients, 30% used CAM, preferably vitamins and micronutrients. Main information sources for CAM methods were physicians/nonmedical practitioners and friends/relatives. CAM therapies were provided mainly by licensed physicians (29%), followed by nonmedical practitioners (14%) and the patients themselves (13%). Although 62% of the CAM users agreed that the oncologist may know about their CAM therapy, a chart entry about CAM use was found only in 41%. CAM is frequently used by hematology/oncology patients. Systematic communication about CAM is essential to avoid possible drug interactions. © 2017 S. Karger AG, Basel.
Utility of CRISPR/Cas9 systems in hematology research.
Lucas, Daniel; O'Leary, Heather A; Ebert, Benjamin L; Cowan, Chad A; Tremblay, Cedric S
2017-10-01
Since the end of the 20th century, novel approaches have emerged to manipulate experimental models of hematological disorders so that they more accurately mirror what is observed in the clinical setting. Despite these technological advances, the characterization of crucial genes for benign or malignant hematological disorders remains challenging, given the dynamic nature of the hematopoietic system and the genetic heterogeneity of these disorders. To overcome this limitation, genome-editing technologies have been developed to manipulate the genome specifically via deletion, insertion, or modification of targeted loci. These technologies have progressed swiftly, allowing their common use to investigate genetic function in experimental hematology. Among them, homologous-recombination-mediated targeting technologies have facilitated the manipulation of specific loci by generating knock-out and knock-in models. Despite promoting significant advances in our understanding of the molecular mechanisms involved in hematology, these inefficient, time-consuming, and labor-intensive approaches did not permit the development of cellular or animal models, recapitulating the complexity of hematological disorders. On October 26, 2016, Drs. Ben Ebert and Chad Cowan shared their knowledge of and experience with the utilization of CRISPR for models of myeloid malignancy, disease, and novel therapeutics in an International Society for Experimental Hematology webinar titled "Utility of CRISPR/Cas9 Systems in Hematology Research." Here, we provide an overview of the topics they covered, including their insights into the novel applications of the technique and its strengths and limitations. Copyright © 2017 ISEH – Society for Hematology and Stem Cells. Published by Elsevier Inc. All rights reserved.
The effects of feeding clinoptilolite on hematology, performance, and health of newborn lambs.
Norouzian, M A; Valizadeh, R; Khadem, A A; Afzalzadeh, A; Nabipour, A
2010-11-01
The effects of feeding clinoptilolite on hematology, performance, and health of newborn Balouchi lambs were evaluated in this experiment. In a completely randomized design, 30 newborn lambs were allocated to three groups and fed by basal diet (C0; without clinoptilolite) and C1 and C2 (the basal diet plus 1.5% and 3% clinoptilolite, respectively, for 6 weeks (3 weeks before and 3 weeks after weaning)). Blood samples were taken from all lambs, at the time when the animals were allocated to the experimental diet and at the end of each week of experiment, and analyzed for hematology, plasma fibrinogen, and total protein. Performance and health of all lambs were measured. Fecal consistency score and diarrhea severity were evaluated. There was no difference between lambs in case of hematological parameters. Lambs fecal consistency score and severity of diarrhea were lowest (P < 0.05) for lambs on C1 and C2 and highest for lambs on C0. Dry matter intake and feed conservation ratio were similar between the groups of lambs fed by different diets, but daily gain of lambs differed significantly (P < 0.05) and was higher in C2. It was concluded that addition of 3% clinoptilolite to starter diet of newborn lamb can reduce incidence and severity of diarrhea, although its effect on hematology and performance was negligible.
Hematology and immunology studies
NASA Technical Reports Server (NTRS)
Kimzey, S. L.; Fischer, C. L.; Johnson, P. C.; Ritzmann, S. E.; Mengel, C. E.
1975-01-01
The hematology and immunology program conducted in support of the Apollo missions was designed to acquire specific laboratory data relative to the assessment of the health status of the astronauts prior to their commitment to space flight. A second objective was to detect and identify any alterations in the normal functions of the immunohematologic systems which could be attributed to space flight exposure, and to evaluate the significance of these changes relative to man's continuing participation in space flight missions. Specific changes observed during the Gemini Program formed the basis for the major portion of the hematology-immunology test schedule. Additional measurements were included when their contribution to the overall interpretation of the flight data base became apparent.
He, Qili; Su, Guoming; Liu, Keliang; Zhang, Fangcheng; Jiang, Yong; Gao, Jun; Liu, Lida; Jiang, Zhongren; Jin, Minwu; Xie, Huiping
2017-01-01
Hematologic and biochemical analytes of Sprague-Dawley rats are commonly used to determine effects that were induced by treatment and to evaluate organ dysfunction in toxicological safety assessments, but reference intervals have not been well established for these analytes. Reference intervals as presently defined for these analytes in Sprague-Dawley rats have not used internationally recommended statistical method nor stratified by sex. Thus, we aimed to establish sex-specific reference intervals for hematologic and biochemical parameters in Sprague-Dawley rats according to Clinical and Laboratory Standards Institute C28-A3 and American Society for Veterinary Clinical Pathology guideline. Hematology and biochemistry blood samples were collected from 500 healthy Sprague-Dawley rats (250 males and 250 females) in the control groups. We measured 24 hematologic analytes with the Sysmex XT-2100i analyzer, 9 biochemical analytes with the Olympus AU400 analyzer. We then determined statistically relevant sex partitions and calculated reference intervals, including corresponding 90% confidence intervals, using nonparametric rank percentile method. We observed that most hematologic and biochemical analytes of Sprague-Dawley rats were significantly influenced by sex. Males had higher hemoglobin, hematocrit, red blood cell count, red cell distribution width, mean corpuscular volume, mean corpuscular hemoglobin, white blood cell count, neutrophils, lymphocytes, monocytes, percentage of neutrophils, percentage of monocytes, alanine aminotransferase, aspartate aminotransferase, and triglycerides compared to females. Females had higher mean corpuscular hemoglobin concentration, plateletcrit, platelet count, eosinophils, percentage of lymphocytes, percentage of eosinophils, creatinine, glucose, total cholesterol and urea compared to males. Sex partition was required for most hematologic and biochemical analytes in Sprague-Dawley rats. We established sex-specific reference
[Oral nutritional supplementation in hematologic patients].
Peñalva, A; San Martín, A; Rosselló, J; Pérez-Portabella, C; Palacios, A; Julià, A; Planas, M
2009-01-01
Hematological patients often present anorexia which along with other secondary effects from the chemotherapy and/or radiotherapy treatments compromise their nutritional status. Oral supplementation can aid to fulfill the energy and protein requirements of these patients. Nevertheless, the use of commercial nutritional supplements normally available, is limited by its poor intake. To evaluate the degree of fulfillment of the prescribed supplements and fulfillment of energy requirements, as well as the development of nutritional status in hematological patients hospitalized for treatment with chemotherapy and/or radiotherapy. Prospective, randomized and open study of inpatients at the hematological ward. Patients were randomized sequentially and they were assigned into 3 different nutritional interventions providing: Group 1 (G1), a flavored supplement; Group 2 (G2): a non flavored (neutral) supplement and Group 3 (G3): "kitchen" foods as supplements. Need and amount of nutritional supplements were provided according to the oral intake previously analyzed. Nutritional assessment (at admission and discharge) was based in the Subjective Global Assessment test (SGA), Risk Nutritional Index (RNI) and percentage of lost weight. Both fulfillment of supplement intake and achievement of energetic requirements were analyzed. 125 patients of 51.3 +/- 16.8 years; 45% men and 55% women. 54% lymphoma, 33% leukemia, 8% myeloma and others 4%. Length of stay (LOS): 7.0 +/- 3.6 d. The nutritional assessment done by SGA showed significant negative changes in G2 and G3 (G1: 30% developed malnutrition and 28% improved their nutritional status, p = NS; G2: 50% developed malnutrition against 7% whom improved their nutritional status, p = 0.002; y G3: 37% developed malnutrition against 21% whom improved their nutritional status, p = 0.02). According to RNI, patients evolved negatively from their nutritional state but no significant differences were found within groups (G1, from 81% of
Unal, Sule; Alanay, Yasemin; Cetin, Mualla; Boduroglu, Koray; Utine, Eda; Cormier-Daire, Valerie; Huber, Celine; Ozsurekci, Yasemin; Kilic, Esra; Simsek Kiper, Ozlem Pelin; Gumruk, Fatma
2014-02-01
Microcephalic osteodysplastic primordial dwarfism type II (MOPD II) is a rare primordial dwarfism that is similar to Seckel syndrome. Seckel syndrome is known to be associated with various hematological abnormalities; however, hematological findings in MOPD II patients have not been previously reported. The present study aimed to describe the hematological findings in a series of eight patients with MOPD II from a single center. The study included eight patients with MOPD II that were analyzed via molecular testing, and physical and laboratory examinations. Molecular testing showed that seven of the eight patients had pericentrin (PCNT) gene mutations. Hematological evaluation showed that 7 (87.5%) patients had thrombocytosis, 6 (75%) had leukocytosis, 5 (62.5%) had both leukocytosis and thrombocytosis, and 2 (25%) had anemia. We report leukocytosis and thrombocytosis as a common hematologic abnormality in patients with MOPD II. The present findings may improve our understanding of the potential function of the PCNT gene in hematopoietic cell proliferation and differentiation. © 2013 Wiley Periodicals, Inc.
Welles, Elizabeth G
2012-01-01
To have an in-clinic hematology instrument in your practice and how it is used are decisions that precede the purchase of an instrument. Advantages and limitations of the various instruments should be considered. Initial purchase cost, reagent/disposable costs, costs of training personnel in the use and care of the instrument, and service/repair contract costs need to be considered. Once the decision is made to have an in-office hematology instrument in your practice you should benefit from having nearly immediate CBC data results that enable you to provide better quality medicine, more rapid clinical decisions, more closely monitor patients for complications of disease or response to treatment. It should also generate revenue and allow some of your staff members to expand and develop their technical skills as they learn the nuances of a new diagnostic tool and how to provide you with the most accurate CBC information. In the final assessment, the addition of an in-office hematology instrument should improve the quality and efficiency of the medical care you provide patients and generate additional practice income.
Fumi, M; Martins, D; Pancione, Y; Sale, S; Rocco, V
2014-12-01
B-chronic lymphocytic leukemia CLL, a neoplastic clonal disorder with monomorphous small B lymphocytes with scanty cytoplasm and clumped chromatin, can be morphologically differentiated in typical and atypical forms with different prognosis: Smudge cells (Gumprecht's shadows) are one of the well-known features of the typical CLL and are much less inconsistent in other different types CLPD. Abbott Cell-Dyn Sapphire uses the fluorescence after staining with the DNA fluorochrome propidium iodide for the measurement of nucleated red blood cells (NRBCs) and nonviable cells (FL3+ cell fraction): We have studied the possible correlation between presence and number of morphologically identifiable smudge cells on smears and the percentage of nonviable cells produced by Cell-Dyn Sapphire. 305 blood samples from 224 patients with B-cell lymphoproliferative disorders and 40 healthy blood donors were analyzed by CBC performed by Cell-Dyn Sapphire, peripheral blood smear, and immunophenotype characterization. FL3+ fraction in CLPD directly correlated with the percentage of smudge cells and is significantly increased in patients with typical B-CLL. This phenomenon is much less evident in patients with atypical/mixed B-CLL and B-NHL. In small laboratories without FCM and cytogenetic, smudge cells%, can be utilized as a preliminary diagnostic and prognostic tool in differential diagnosis of CLPD. © 2014 John Wiley & Sons Ltd.
Saret, Cayla J; Winn, Aaron N; Shah, Gunjan; Parsons, Susan K; Lin, Pei-Jung; Cohen, Joshua T; Neumann, Peter J
2015-03-19
We analyzed cost-effectiveness studies related to hematologic malignancies from the Tufts Medical Center Cost-Effectiveness Analysis Registry (www.cearegistry.org), focusing on studies of innovative therapies. Studies that met inclusion criteria were categorized by 4 cancer types (chronic myeloid leukemia, chronic lymphocytic leukemia, non-Hodgkin lymphoma, and multiple myeloma) and 9 treatment agents (interferon-α, alemtuzumab, bendamustine, bortezomib, dasatinib, imatinib, lenalidomide, rituximab alone or in combination, and thalidomide). We examined study characteristics and stratified cost-effectiveness ratios by type of cancer, treatment, funder, and year of study publication. Twenty-nine studies published in the years 1996-2012 (including 44 cost-effectiveness ratios) met inclusion criteria, 22 (76%) of which were industry funded. Most ratios fell below $50,000 per quality-adjusted life-years (QALY) (73%) and $100,000/QALY (86%). Industry-funded studies (n = 22) reported a lower median ratio ($26,000/QALY) than others (n = 7; $33,000/QALY), although the difference was not statistically significant. Published data suggest that innovative treatments for hematologic malignancies may provide reasonable value for money. © 2015 by The American Society of Hematology.
Patient-reported outcomes in drug development for hematology.
Acquadro, Catherine; Regnault, Antoine
2015-01-01
Patient-reported outcomes (PROs) are any outcome evaluated directly by the patient himself and based on the patient's perception of a disease and its treatment(s). PROs are direct outcome measures that can be used as clinical meaningful endpoints to characterize treatment benefit. They provide unique and important information about the effect of treatment from a patient's view. However, PROs will only be considered adequate if the assessment is well-defined and reliable. In 2009, the FDA has issued a guidance, which defines good measurement principles to consider for PRO measures intended to give evidence of treatment benefit in drug development. In hematologic clinical trials, when applied rigorously, they may be used to evaluate overall treatment effectiveness, treatment toxicity, and quality of patient's well-being at short-term and long-term after treatment from a patient's perspective. In situations in which multiple treatment options exist with similar survival outcome or if a new therapeutic strategy needs to be evaluated, the inclusion of PROs as an endpoint can provide additional data and help in clinical decision making. Given the diversity of the hematological field, the approach to measurement needs to be tailored for each specific situation. The importance of PROs in hematologic diseases has been highlighted in a number of international recommendations. In addition, new perspectives in the regulatory field will enhance the inclusion of PRO endpoints in clinical trials in hematology, allowing the voice of the patients with hematologic diseases to be taken into greater consideration in the development of new drugs. © 2015 by The American Society of Hematology. All rights reserved.
Process development for automated solar cell and module production. Task 4: Automated array assembly
NASA Technical Reports Server (NTRS)
1980-01-01
A process sequence which can be used in conjunction with automated equipment for the mass production of solar cell modules for terrestrial use was developed. The process sequence was then critically analyzed from a technical and economic standpoint to determine the technological readiness of certain process steps for implementation. The steps receiving analysis were: back contact metallization, automated cell array layup/interconnect, and module edge sealing. For automated layup/interconnect, both hard automation and programmable automation (using an industrial robot) were studied. The programmable automation system was then selected for actual hardware development.
Hardware Realization of an Ethernet Packet Analyzer Search Engine
2000-06-30
specific for the home automation industry. This analyzer will be at the gateway of a network and analyze Ethernet packets as they go by. It will keep... home automation and not the computer network. This system is a stand-alone real-time network analyzer capable of decoding Ethernet protocols. The
Płoszczyca, Kamila; Langfort, Józef; Czuba, Miłosz
2018-01-01
Background: One of the goals of altitude training is to increase blood oxygen-carrying capacity in order to improve sea-level endurance performance in athletes. The elevated erythropoietin (EPO) production in hypoxia is a key factor in the achievement of enhanced hematological variables. The level of the EPO increase and acceleration of erythropoiesis depend on the duration of exposure and degree of hypoxia. Furthermore, many other factors may affect the hematological response to altitude training. Aim: The purpose of this narrative review was to: (1) analyze the kinetics of EPO and hematological variables during and after altitude training; (2) summarize the current state of knowledge about the possible causes of individual or cohort differences in EPO and hematological response to altitude training; (3) formulate practical guidelines for athletes to improve the efficiency of altitude training. Methods: A narrative review was performed following an electronic search of the databases PubMed/MEDLINE and SPORTDiscus via EBSCO for all English-language articles published between 1997 and 2017. Results: Complete unification of results from studies on EPO kinetics was difficult due to different time and frequency of blood sampling by different researchers during and after altitude training, but the data presented in the reviewed literature allowed us to detect certain trends. The results of the reviewed studies were divergent and indicated either increase or no change of hematological variables following altitude training. Factors that may affect the hematological response to altitude training include hypoxic dose, training content, training background of athletes, and/or individual variability of EPO production. Conclusions: Despite the potential benefits arising from altitude training, its effectiveness in improving hematological variables is still debatable. Further research and better understanding of factors influencing the response to altitude, as well as factors
Jiang, Ying; Wan, Liping; Qin, Youwen; Wang, Xiaorui; Yan, Shike; Xie, Kuangcheng; Wang, Chun
2015-01-01
In this study we investigated the correlation between donor chimerism status and disease relapse following allogeneic hematopoietic stem cell transplantation (allo-HSCT). The chimerism of Fluorescence-activated cell sorter (FACS) sorted CD3+T lymphocytes of 153 cases, CD56+CD16+NK lymphocytes of 153 cases and CD19+B lymphocytes of 31 cases with acute B lymphoblastic leukemia (B-ALL) was analyzed post-transplant utilizing polymerase chain reaction amplification of short tandem repeats (PCR-STR). A total of 33 patients (33/153, 21.6%) had recurrent disease. The positive predictive values of declining donor chimerism for hematologic and isolated extramedullary relapse were 58.8% and 10% (P=0.018, Chi-Square). The positive predictive values of declining donor chimerism in BMB, BMT, BMNK and PBB for hematologic relapse were 11.6%, 0%, 0% and 0% under close monitoring in patients with B-ALL. Only the donor chimerism in BMB significantly decreased in the group with hematologic relapse as compared with the group without hematologic relapse (P=0.00, Independent-samples T test) in patients with B-ALL. The median drop of donor chimerism in PBT, BMT, PBNK and BMNK were 0%, 0%, 5.9% and 2.8% one or two weeks prior to hematologic relapse in patients with non-B-ALL. The donor chimerism in PBNK significantly decreased prior to hematologic relapse in the group with hematologic relapse as compared with the group without hematologic relapse (P=0.022, Independent-samples T test).These data suggest donor chimerism of BMB can be used to predict the occurrence of hematologic relapse in patients with B-ALL. Donor chimerism decrease in PBNK was associated with a somewhat increased risk of hematologic relapse in patients with non-B-ALL. Therefore, our results reveal a more effective path to individually predict for hematologic relapse by dynamic monitoring different cell lineages in different disease.
Modular workcells: modern methods for laboratory automation.
Felder, R A
1998-12-01
Laboratory automation is beginning to become an indispensable survival tool for laboratories facing difficult market competition. However, estimates suggest that only 8% of laboratories will be able to afford total laboratory automation systems. Therefore, automation vendors have developed alternative hardware configurations called 'modular automation', to fit the smaller laboratory. Modular automation consists of consolidated analyzers, integrated analyzers, modular workcells, and pre- and post-analytical automation. These terms will be defined in this paper. Using a modular automation model, the automated core laboratory will become a site where laboratory data is evaluated by trained professionals to provide diagnostic information to practising physicians. Modem software information management and process control tools will complement modular hardware. Proper standardization that will allow vendor-independent modular configurations will assure success of this revolutionary new technology.
Sousa, David Cordeiro; Rodrigues, Filipe Brogueira; Duarte, Gonçalo; Campos, Fátima; Pinto, Filomena; Vaz-Carneiro, A
2016-12-01
Demographic and clinical characteristics associated with nonarteritic anterior ischemic optic neuropathy (NAION) are well described. Patients with hematologic neoplasms may share some of these characteristics, and it may be useful clinically to better understand this set of patients. Our objective is to review systematically the characteristics of patients with both hematologic malignancies and NAION. Systematic review. Patients with NAION diagnosis related in time to a hematologic neoplasm. Data sources for the study included MEDLINE, Web of Science, LILACS, SciELO, and OpenGrey. The study eligibility criteria included case reports and case series. We found 261 records, with 15 studies included plus our case report. A total of 19 patients (8 female) with mean age of 54.6 years (range, 12-87) were analyzed: 37% (7) non-Hodgkin lymphoma; 26% (5) myeloproliferative neoplasms; 21% (4) myelodysplasia; 16% (3) leukemias. The limitations included verification bias, inability to test statistical association between NAION and hematologic neoplasms, the small number of cases, and confounding factors related to medical history and specific interventions in each case limited the robustness of our conclusions. Our results identified the characteristics of patients with NAION and hematologic neoplasms related in time. Additional observational studies may enlighten the importance of looking for evidence of an occult neoplastic disorder in patients presenting with NAION. A prompt diagnosis would be of invaluable significance for the best management, in terms of follow-up and therapeutics. Copyright © 2016 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.
21 CFR 864.8625 - Hematology quality control mixture.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hematology quality control mixture. 864.8625 Section 864.8625 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... quality control mixture. (a) Identification. A hematology quality control mixture is a device used to...
Rogers, Linda B; Kaack, M Bernice; Henson, Michael C; Rasmussen, Terri; Henson, Elizabeth; Veazey, Ronald S; Krogstad, Donald J; Davison, Billie B
2005-06-01
Hematology and flow cytometry reference values for rhesus umbilical cord blood (UCB) were established in 17 healthy infant rhesus monkeys delivered by elective cesarean section 10 days preterm. The infants were born to age matched, singly caged primigravid or secundigravid dams. The hematology and flow cytometry values were determined by automated cell counter and by FACS. No significant differences were observed with respect to infant gender. With respect to gravida, the primigravid infants had a significantly higher percentage (P= 0.05) of CD20(+) B lymphocytes in UCB. These results provide useful reference values for future studies of maternal - fetal disease transmission, vaccine and drug evaluation in non-human primate pregnancy, as well as fetal programming and immune modulation, gene therapy and the use of UCB as a source of stem cells for research and transplantation. Importantly, our results suggest that maternal gravidity may be an important variable to consider.
Egbuniwe, Ifeanyichukwu C; Ayo, Joseph O; Kawu, Mohammed U; Mohammed, Aliyu
2018-02-05
Heat stress is a major problem in poultry production in tropical regions. Assessing the impact of thermally stressful environmental conditions on the welfare of broiler chickens is of great importance. Behavioral responses in a novel environment and hematology of broiler chickens administered with betaine and/or ascorbic acid (AA) during the hot-dry season were evaluated. Broiler chickens were randomly divided into four groups: Group I (control) was given sterile water, Group II was given betaine, Group III was given AA, and Group IV received betaine + AA orally and daily for 42 days. An open-field test was used to assess behavior. Hematological parameters were obtained using a hematology auto-analyzer. The natural environmental conditions were predominantly outside the thermoneutral zone for broiler chickens. Results demonstrated that treated groups exhibited improved ability to adjust faster to a new environment and better hematological responses than controls, evidenced by enhanced behavioral responses, oxygen-carrying capacity, and immune responses of broiler chickens under unfavorable environmental conditions. Betaine and/or AA administration to broiler chickens improved some behavioral responses, hemoglobin concentrations, packed cell volume, and total leukocyte count during the hot-dry season.
NASA Astrophysics Data System (ADS)
Bachri, M. S.; Yuliani, S.; Sari, A. K.
2017-11-01
Nutmeg is dried kernel of broadly ovoid seed of Myristica fragrans Houtt. It has been mentioned in ethnomedical literature as aphrodisiac, stomachic, carminative, tonic, and nervous stimulant. In order to establish the safety of nutmeg, the effect of the repeated administration of nutmeg is needed. The study was aimed to determine the toxic effect of subchronic administration of nutmeg ethanolic extract to hematological parameters in rat. A total of 28 male adult Wistar rats divided into 4 groups. Group I as control was given by 0.5% CMC-suspension, group II, III, and IV were given by 50, 100, and 200 mg/kg bw, respectively, of nutmeg ethanolic extract. The treatments were administered daily for 31 days. On day 31 bloods were taken from orbital sinus. The hematological parameter consisted of the numbers of erythrocyte and leukocyte as well as hemoglobin and total protein levels were measured. The data were statistically analyzed by one way Anova followed by LSD test. All of observed hematological parameters in rats showed that there were no significant difference between the nutmeg ethanolic extract treated groups and control group. The result indicated that the subchronic administration of 50, 100, and 200 mg/kg bw of nutmeg ethanolic extract did not cause the change of hematological parameters in rat.
Relating tumor score to hematology in green turtles with fibropapillomatosis in Hawaii
Work, Thierry M.; Balazs, George H.
1999-01-01
The relationship between hematologic status and severity of tumor affliction in green turtles (Chelonia mydas) with fibropapillomatosis (FP) was examined. During 1 wk periods in July 1997 and July 1998, we bled 108 free-ranging green turtles from Pala'au (Molokai, Hawaii, USA) where FP is endemic. Blood was analyzed for hematocrit, estimated total solids, total white blood cell (WBC) count and differential WBC count. Each turtle was assigned a subjective tumor score ranging from 0 (no visible external tumors) to 3 (heavily tumored) that indicated the severity of FP. There was a progressive increase in monocytes and a decrease in all other hematologic parameters except heterophils and total numbers of white blood cells as tumor score increased. These data indicate that tumor score can relate to physiologic status of green turtles afflicted with FP, and that tumor score is a useful field monitor of severity of FP in this species.
Elements of EAF automation processes
NASA Astrophysics Data System (ADS)
Ioana, A.; Constantin, N.; Dragna, E. C.
2017-01-01
Our article presents elements of Electric Arc Furnace (EAF) automation. So, we present and analyze detailed two automation schemes: the scheme of electrical EAF automation system; the scheme of thermic EAF automation system. The application results of these scheme of automation consists in: the sensitive reduction of specific consummation of electrical energy of Electric Arc Furnace, increasing the productivity of Electric Arc Furnace, increase the quality of the developed steel, increasing the durability of the building elements of Electric Arc Furnace.
Flight-deck automation - Promises and problems
NASA Technical Reports Server (NTRS)
Wiener, E. L.; Curry, R. E.
1980-01-01
The paper analyzes the role of human factors in flight-deck automation, identifies problem areas, and suggests design guidelines. Flight-deck automation using microprocessor technology and display systems improves performance and safety while leading to a decrease in size, cost, and power consumption. On the other hand negative factors such as failure of automatic equipment, automation-induced error compounded by crew error, crew error in equipment set-up, failure to heed automatic alarms, and loss of proficiency must also be taken into account. Among the problem areas discussed are automation of control tasks, monitoring of complex systems, psychosocial aspects of automation, and alerting and warning systems. Guidelines are suggested for designing, utilising, and improving control and monitoring systems. Investigation into flight-deck automation systems is important as the knowledge gained can be applied to other systems such as air traffic control and nuclear power generation, but the many problems encountered with automated systems need to be analyzed and overcome in future research.
Chemotherapy and Cardiotoxicity in Hematologic Malignancies.
Stellitano, Antonio; Fedele, Roberta; Barilla, Santina; Iaria, Antonino; Rao, Carmelo Massimiliano; Martino, Massimo
2017-01-01
Antineoplastic agents affect the cardiovascular system, and the incidence of cardiotoxicity is continuously growing in patients with hematologic malignancies and treated with antineoplastic therapy. In this mini-review, we analyzed existing literature which evaluates the likelihood of cardiotoxicity related to the main agents employed in the treatment of hematologic malignancies. There is a significant need to optimize the early identification of patients who are at risk of cardiotoxicity. The conventional echocardiographic measurements used to detect cardiac alterations, such as LVEF, fractional shortening, diameters and volumes, allow only a late diagnosis of cardiac dysfunction, which might be already irreversible. The early identification of patients at risk for rapid progression towards irreversible cardiac failure has a primary purpose, the opportunity for them to benefit from early preventive and therapeutic measures. A useful imaging technique that points in this direction detecting subclinical LVD may be the speckle tracking echocardiography, that has demonstrated a previous detection of myocardial contractile dysfunction compared to the traditional left ventricular ejection fraction. In this view, the discovery of new biomarkers to identify patients at a high risk for the development of these complications is another priority. Cardiotoxicity induced by anticancer drugs is always the outcome of several concurrent factors. It is plausible that an asymptomatic dysfunction precedes clinical events. During this asymptomatic phase, an early treatment prepares the patient for cardiovascular "safety" conditions; on the other hand, a late or missing treatment paves the ground for the development of future cardiac events. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Seguel, Mauricio; Muñoz, Francisco; Keenan, Alessandra; Perez-Venegas, Diego J; DeRango, Eugene; Paves, Hector; Gottdenker, Nicole; Müller, Ananda
2016-07-01
The establishment of clinical pathology baseline data is critical to evaluate temporal and spatial changes in marine mammal groups. Despite increased availability of studies on hematology and biochemistry of marine mammals, reference ranges are lacking for many populations, especially among fur seal species. During the austral summers of 2014 and 2015, we evaluated basic hematologic and biochemical parameters in clinically healthy, physically restrained South American fur seal ( Arctocephalus australis ) lactating females and 2-mo-old pups. We also assessed the temporal variation of hematology parameters on the pups during their first 2 mo of life. Reference ranges of lactating females were similar to those previously reported in other fur seal species. In the case of pups, reference ranges are similar to values previously reported in sea lion species. As expected, most biochemical and hematologic values differ significantly between adult females and pups. As in other otariids, South American fur seals pups are born with higher values of total red blood cells, hemoglobin, and packed cell volume, and lower numbers of total leukocytes, neutrophils, lymphocytes, and eosinophils. To the best of our knowledge, data on hematology reference values for South American fur seals has not been previously reported and is useful for continued health monitoring of this species, as well as for comparisons with other otariid groups.
BEST-TEST2: assessment of hematology trainee knowledge of transfusion medicine.
Lin, Yulia; Tinmouth, Alan; Mallick, Ranjeeta; Haspel, Richard L
2016-02-01
As transfusion is a common therapy and key component in every hematologist's practice, hematology training programs should dedicate significant time and effort to delivering high-quality transfusion medicine education to their trainees. The current state of hematology trainee knowledge of transfusion medicine is not known. A validated assessment tool developed by the Biomedical Excellence for Safer Transfusion (BEST) Collaborative was used to assess prior transfusion medicine education, attitudes, perceived ability, and transfusion medicine knowledge of hematology trainees. A total of 149 hematology trainees at 17 international sites were assessed. The overall mean exam score was 61.6% (standard deviation, 13.4%; range, 30%-100%) with no correlation in exam scores with postgraduate year or previous transfusion medicine education in medical school or internal medicine residency. However, better scores correlated with 3 or more hours of transfusion medicine education (p = 0.0003) and perceived higher-quality education during hematology training (p = 0.03). Hematology trainees at US sites, where hematology is often combined with oncology training, had statistically lower scores than trainees at non-US sites (56.2% vs. 67.4%; p < 0.0001). In terms of topic areas, although 93% of participants had obtained consent for transfusion, the lowest scores were on transfusion reaction-related questions. Given the overall poor performance, this study serves as an impetus for all hematology training programs to reevaluate the quality and quantity of transfusion medicine training and can assist in the development of targeted curricula. © 2015 AABB.
Lin, Na; Huang, Hai-Long; Wang, Yan; Zheng, Lin; Fang, Xiang-Qun; Cai, Mei-Ying; Wang, Lin-Shuo; Liu, He-Kun; Xu, Liang-Pu; Lin, Yuan
2016-08-01
To investigate the hematologic characteristics and gene diagnosis of patients with Thailand deleted α-thalassemia 1, so as to provide the information for clinical genetic counseling. The clinical data of 32 patients with Thailand delated α-thalassemia 1 were analyzed retrospectively; the hematologic characteristics and gene diagnosis of Thailand deleted type were investigated by using routine hematologic examination, genetic detection of common thalassemia and Thailand deleted α-thalassemia 1. Among 32 cases, the Thailand deleted α-thalassemia 1 heterozygote was found in 29 cases, the Thailand deleted α-thalassemia 1 and α(3.7) gene deletion double heterozygote were found in 1 case, the Thailand deleted α-thalassemia 1 with β-thalassemia (1 case with codons 41-42 mutation heterozygous, 1 case with CD17 mutation heterozygous) was found in 2 cases by detection. The MCV and MCH levels were decreased in all cases of Thailand deleted thalassemia 1, there were significant differences in RBC, MCV, MCH (P<0.05) between normal control and Thailand deletion α-thalassemia 1 group; there were also significant differences in MCHC (P<0.05) between Southeast asia thalassemia and Thailand deleted α-thalassemia 1 group. There are no significant differences in hematological parameters except MCHC between Southeast asia thalassemia and Thailand deleted α-thalassemia 1 group. moreover the Thailand deleted α-thalassemia 1 in a certain proportion exists in area with high incidence of thalassemia, therefor the clinicians should pay more attention to the screen and diagnosis of Thailand delated α-thalassemia and can exactly diagnose the Thailand delected α-thalassemia 1 on the basis of comprehensive analysis of conventional and Thailand delected α-thalassemia 1 detection results, clinical presentation, hematologic parameters and ultrasonic examination, so as to avoid the birth of child with severe and intermidiate type α-thalassemia caused by Thailand deleted
Ethical considerations in genomic testing for hematologic disorders.
Marron, Jonathan M; Joffe, Steven
2017-07-27
As our technological capacities improve, genomic testing is increasingly integrating into patient care. The field of clinical hematology is no exception. Genomic testing carries great promise, but several ethical issues must be considered whenever such testing is performed. This review addresses these ethical considerations, including issues surrounding informed consent and the uncertainty of the results of genomic testing; the challenge of incidental findings; and possible inequities in access to and benefit from such testing. Genomic testing is likely to transform the practice of both benign and malignant hematology, but clinicians must carefully consider these core ethical issues in order to make the most of this exciting and evolving technology. © 2017 by The American Society of Hematology.
Effects of dance therapy on the selected hematological and rheological indicators in older women.
Filar-Mierzwa, Katarzyna; Marchewka, Anna; Bac, Aneta; Kulis, Aleksandra; Dąbrowski, Zbigniew; Teległów, Aneta
2017-01-01
The aim of this study was to analyze the effects of dance therapy on selected hematological and rheological indicators in older women. The study included 30 women (aged 71.8±7.4), and the control group comprised of 10 women of corresponding age. Women from the experimental group were subjected to a five-month dance therapy program (three 45-minute sessions per week); women from the control group were not involved in any regular physical activity. Blood samples from all the women were examined for hematological, rheological, and biochemical parameters prior to the study and five months thereafter. The dance therapy program was reflected by a significant improvement of erythrocyte count and hematocrit. Furthermore, the dance therapy resulted in a significant increase in the plasma viscosity, while no significant changes in glucose and fibrinogen levels were noted. Dance therapy modulates selected hematological parameters of older women; it leads to increase in erythrocyte count and hematocrit level. Dance therapy is reflected by higher plasma viscosity. Concentrations of fibrinogen and glucose are not affected by the dance therapy in older women, suggesting maintenance of homeostasis. Those findings advocate implementation of dance therapy programs in older women.
[Hematological changes in adolescent anorexia nervosa].
Bühren, Katharina; Gärtner, Laura; Kennes, Lieven N; Seitz, Jochen; Hagenah, Ulrich; Herpertz-Dahlmann, Beate
2014-01-01
Hematological changes often occur in patients with acute anorexia nervosa (AN). However, the relationship between these disturbances and other clinical parameters remains unclear. Leucocyte, erythrocyte, and thrombocyte counts as well as hematocrit, hemoglobin, and differential blood counts were collected at admission and after weight restoration in 88 female adolescent patients with the diagnosis of AN according to DSM-IV. These were then compared to clinical parameters. At admission, there were mild changes in the blood count, most of which, however, were reversible after weight gain. Patients with a greater weight loss, a lower age-adjusted BMI, and a history of taking psychotropic drugs were more likely to develop hematological abnormalities. Although most of the hematological changes in adolescent patients with AN were mild, patients with high weight loss and/or low age-adjusted BMI as well as those on psychotropic medication should be monitored carefully in order to avoid severe medical complications. An altered immune function in adult patients with chronic AN might contribute to a higher rate of infections and thus to an increased mortality.
Restructuring of international council for standardization in haematology (ICSH) in Asia.
Tatsumi, N; Lewis, S M
2002-08-01
Standardization and harmonization in Laboratory testing are a key issue in the midst of globalization era, because most of laboratory testing has been currently achieved with various kinds of automated systems. In the developed countries, automated systems with highly-regulated principles are commonly used in the routine laboratory. However, there are so many undeveloped and developing countries in Asia that diversity of testing levels can be observed in the area. Some laboratories use glass chamber method for blood cell counting, while other laboratory use semi-automated or fully automated analyzers for complete blood count. International standardization on Hematology is focused on the developed system but not for the developing system. Established standardized documents therefore whould not be unsuitable for Asian societies. In the context, International Council for Standardization in Hematology (ICSH) changed its rules to adjust our Asian Societies and ICSH started to restructure the body. International ICSH society is divided into 5 region sub-groups. Asian area is able to possess one new sub-society, ICSH-Asia. Its reconstruction work has been just started with Asain colleagues, and we are now extending the new societies to discuss Asian problems on the quality of hematology testing.
Silva, A S R; Santhiago, V; Papoti, M; Gobatto, C A
2008-04-01
We assessed the responses of hematological parameters and their relationship to the anaerobic threshold of Brazilian soccer players during a training program. Twelve athletes were evaluated at the beginning (week 0, T1), in the middle (week 6, T2), and at the end (week 12, T3) of the soccer training program. On the first day at 7:30 am, before collecting the blood sample at rest for the determination of the hematological parameters, the athletes were conducted to the anthropometric evaluation. On the second day at 8:30 am, the athletes had their anaerobic threshold measured. Analysis of variance with Newman-Keuls'post hoc was used for statistical comparisons between the parameters measured during the soccer training program. Correlations between the parameters analyzed were determined using the Pearson's correlation coefficient. Erythrocytes concentration, hemoglobin, and hematocrit were significantly increased from T1 to T2. The specific soccer training program led to a rise in erythrocytes, hemoglobin, and hematocrit from T1 to T2. We assumed that these results occurred due to the plasma volume reduction and may be explained by the soccer training program characteristics. Furthermore, we did not observe any correlation between the anaerobic threshold and the hematological parameters.
Weights, hematology and serum chemistry of seven species of free-ranging tropical pelagic seabirds
Work, Thierry M.
1996-01-01
I established reference values for weight, hematology, and serum chemistry for seven species of free-ranging Hawaiian tropical pelagic seabirds comprising three orders (Procellariiformes, Pelecaniformes, Charadriiformes) and six families (Procellariidae, Phaethontidae, Diomedeidae, Sulidae, Fregatidae, and Laridae). Species examined included 84 Hawaiian dark-rumped petrels (Pterodoma phaeopygia), 90 wedge-tailed shearwaters (Puffinus pacificus), 151 Laysan albatrosses (Diomedea immutabilis), 69 red-footed boobies (Sula sula), 154 red-tailed tropicbirds (Phaeton rubricauda), 90 great frigatebirds (Fregata minor), and 72 sooty terns (Sterna fuscata). Hematocrit, total plasma solids, total and differential white cell counts, serum glucose, calcium, phosphorus, uric acid, total protein, albumin, globulin, aspartate aminotransferase and creatinine phosphokinase were analyzed. Among and within species, hematology and chemistry values varied with age, sex, season, and island of collection. Despite this variation, order-wide trends were observed.
B-Cell Hematologic Malignancy Vaccination Registry
2017-12-29
Monoclonal Gammopathy of Undetermined Significance; Multiple Myeloma; Waldenstrom Macroglobulinemia; Lymphocytosis; Lymphoma, Non-Hodgkin; B-Cell Chronic Lymphocytic Leukemia; Hematological Malignancies
Laboratory hematology in the history of Clinical Chemistry and Laboratory Medicine.
Hoffmann, Johannes J M L
2013-01-01
For the occasion of the 50th anniversary of the journal Clinical Chemistry and Laboratory Medicine (CCLM), an historic overview of papers that the journal has published in the field of laboratory hematology (LH) is presented. All past volumes of CCLM were screened for papers on LH and these were categorized. Bibliographic data of these papers were also analyzed. CCLM published in total 387 LH papers. The absolute number of LH papers published annually showed a significant increase over the years since 1985. Also the share of LH papers demonstrated a steady increase (overall mean 5%, but mean 8% over the past 4 years). The most frequent category was coagulation and fibrinolysis (23.5%). Authors from Germany contributed the most LH papers to the journal (22.7%), followed by the Netherlands and Italy (16.3 and 13.2%, respectively). Recent citation data indicated that other publications cited LH review papers much more frequently than other types of papers. The history of the journal reflects the emergence and development of laboratory hematology as a separate discipline of laboratory medicine.
Pediatric hematology in Poland: past and present.
Boguslawska-Jaworska, J
1994-01-01
Pediatric hematology/oncology gradually developed in Poland in the beginning of the 20th century. The first pediatric hematology books written by M. Erlich were published in 1918 and 1924. In 1939, Jan Raszek-Rosenbusch was the first to use the intramedullary route of injection of living bone marrow cells in children suffering from lymphatic leukemia. The national cooperative chemotherapy group in Poland was formed in 1974. The studies carried out by the group in children with leukemia and lymphoma are documented by publications in international journals.
Analyzing Library Literature on Academic Library Automation: Authorship and Subject Coverage.
ERIC Educational Resources Information Center
Lin, Pei-Yu
The purpose of this study is to identify and determine the extent of technological change in the development of automation as it is reflected in the professional literature and the rates at which males and females contribute to this literature. A database search of Library Literature on WILSONDISC was undertaken to identify publications written in…
Lewbart, Gregory A; Ulloa, Catalina; Deresienski, Diane; Regalado, Cristina; Muñoz-Pérez, Juan-Pablo; Garcia, Juan; Hardesty, Britta Denise; Valle, Carlos A
2017-12-01
The red-footed booby ( Sula sula) is a widely distributed sulid native to the Galápagos archipelago. Hematology and blood chemistry parameters have been published for this species, but not from the San Cristóbal rookery. Analyses were run on blood samples drawn from 31 manually restrained red-footed boobies that were captured by hand from their nests at Punta Pitt on San Cristóbal Island. A portable blood analyzer (iSTAT) was used to obtain near immediate field results for pH, partial pressure of oxygen, partial pressure of carbon dioxide, bicarbonate, hematocrit, hemoglobin, sodium, potassium, ionized calcium, and glucose. Blood lactate was measured using a portable Lactate Plus™ analyzer. Average heart rate, respiratory rate, body weight, body temperature, and biochemistry and hematology parameters were comparable to those of healthy individuals of other sulids. The reported results provide baseline data that can be used for comparisons among populations and in detecting changes in health status among Galápagos red-footed boobies.
Médaille, C; Briend-Marchal, A; Braun, J P
2006-03-01
Most hematologic analyses are performed within a short time of blood sampling, but samples collected at the end of a week may have to be stored for up to 2 days. The stability of hematologic constituents is poorly documented. The objective of this study was to compare the results of RBC, WBC and platelet counts, hemoglobin (Hgb) concentration, and MCV before and after storage of canine blood at room temperature for 24 and 48 hours. One hundred fifty-two K3-EDTA canine blood specimens from 2 veterinary hospitals were analyzed within 4 hours of collection, then 24 and 48 hours later with a Coulter T540 hematology analyzer. Results were compared by Passing-Bablock agreement, difference plots, and according to their classification as normal or abnormal based on reference intervals. RBC count and Hgb concentration were stable for the duration of the study. Differences in WBC and platelet counts varied with the specimen, independently of the initial value. MCV increased consistently over the 2 days. However, only a few results were misclassified. Whole blood specimens stored for up to 2 days at room temperature are suitable for cell counts and Hgb measurement. However, potential variations have to be known to avoid misinterpretations, especially near the decision limits.
Jiang, Ni; Zhu, Xishan; Zhang, Hongmei; Wang, Xiaoli; Zhou, Xinna; Gu, Jiezhun; Chen, Baoan; Ren, Jun
2014-01-01
Methylenetetrahydrofolate reductase (MTHFR) is the key enzyme for folate metabolism. Previous studies suggest a relationship between its single nucleotide polymorphisms (SNP) of C677T and A1298C with a variety of tumor susceptibility including hematological malignancy. SNP frequency distribution in different ethnic populations might lead to differences in disease susceptibility. There has been little research in Chinese people on the MTHFR SNP with the susceptibility of the hematological malignancy. Therefore, this study investigated the relationship between MTHFR SNPs and hematological malignancy in Jiangsu province in China. Gene microarray was used to detect MTHFR C677T and A1298C single nucleotide polymorphism loci on 157 healthy controls and 127 patients from Jiangsu province with hematological malignancies (30 with multiple myeloma, 28 with non-Hodgkin's lymphoma, 22 with acute lymphoblastic leukemia, 40 with acute myeloid leukemia, and seven with chronic myeloid leukemia). The allele frequency of 677T was 41.3% in patients and 33.1% in controls, showed significant difference (chi2 = 4.08, p = 0.043); 677TT genotype with a high susceptibility to hematological malignancy (OR 1.96, 95% CI 1.01 - 4.45, p = 0.041). In subgroup analyses, the genotypes 677TT and 1298CC were associated with significantly increased multiple myeloma risk (TT vs. CC: OR 8.92, 95% CI 1.06 - 75.24, p = 0.006; CC vs. AA: OR = 4.80, 95% CI 1.56 - 14.73, p = 0.044). No associations were found between polymorphisms and susceptibilities to acute lymphoblastic leukemia, acute myeloid leukemia, or non-Hodgkin's lymphoma. MTHFRC677T polymorphisms influence the risk of hematological malignancy among the population in Jiangsu province. Both MTHFR 677TT and MTHFR 1298CC genotypes increase susceptibility to myeloid leukemia.
Preanalytical Errors in Hematology Laboratory- an Avoidable Incompetence.
HarsimranKaur, Vikram Narang; Selhi, Pavneet Kaur; Sood, Neena; Singh, Aminder
2016-01-01
Quality assurance in the hematology laboratory is a must to ensure laboratory users of reliable test results with high degree of precision and accuracy. Even after so many advances in hematology laboratory practice, pre-analytical errors remain a challenge for practicing pathologists. This study was undertaken with an objective to evaluate the types and frequency of preanalytical errors in hematology laboratory of our center. All the samples received in the Hematology Laboratory of Dayanand Medical College and Hospital, Ludhiana, India over a period of one year (July 2013-July 2014) were included in the study and preanalytical variables like clotted samples, quantity not sufficient, wrong sample, without label, wrong label were studied. Of 471,006 samples received in the laboratory, preanalytical errors, as per the above mentioned categories was found in 1802 samples. The most common error was clotted samples (1332 samples, 0.28% of the total samples) followed by quantity not sufficient (328 sample, 0.06%), wrong sample (96 samples, 0.02%), without label (24 samples, 0.005%) and wrong label (22 samples, 0.005%). Preanalytical errors are frequent in laboratories and can be corrected by regular analysis of the variables involved. Rectification can be done by regular education of the staff.
Hematological values for free-ranging yellow-bellied marmots.
Armitage, K B
1983-01-01
1. Hemoglobin, packed cell volume, erythrocytes, leucocytes, MCV, MCH and MCHC were determined for a population of Marmota flaviventris over a period of seven years. 2. There was no significant difference in hematology among years, between sexes, or between seasons for adults and yearlings. 3. Early season juveniles had significantly lower PCV, Hb and erythrocyte counts than did late season juveniles. There were no significant differences in hematological values among adults, yearlings and late season juveniles. 4. Juveniles had significantly lower leucocycte counts than adults and yearlings. 5. PCV of marmots responds to acclimatization. 6. Hematological values of scuirids are adaptive to environmental factors such as hypoxia of burrows and high altitude, temperature and metabolic rate. 7. PCV of yellow-bellied marmots evidences an adaptive response to high altitude when compared to the closely-related woodchuck, M. monax.
Selecting automation for the clinical chemistry laboratory.
Melanson, Stacy E F; Lindeman, Neal I; Jarolim, Petr
2007-07-01
Laboratory automation proposes to improve the quality and efficiency of laboratory operations, and may provide a solution to the quality demands and staff shortages faced by today's clinical laboratories. Several vendors offer automation systems in the United States, with both subtle and obvious differences. Arriving at a decision to automate, and the ensuing evaluation of available products, can be time-consuming and challenging. Although considerable discussion concerning the decision to automate has been published, relatively little attention has been paid to the process of evaluating and selecting automation systems. To outline a process for evaluating and selecting automation systems as a reference for laboratories contemplating laboratory automation. Our Clinical Chemistry Laboratory staff recently evaluated all major laboratory automation systems in the United States, with their respective chemistry and immunochemistry analyzers. Our experience is described and organized according to the selection process, the important considerations in clinical chemistry automation, decisions and implementation, and we give conclusions pertaining to this experience. Including the formation of a committee, workflow analysis, submitting a request for proposal, site visits, and making a final decision, the process of selecting chemistry automation took approximately 14 months. We outline important considerations in automation design, preanalytical processing, analyzer selection, postanalytical storage, and data management. Selecting clinical chemistry laboratory automation is a complex, time-consuming process. Laboratories considering laboratory automation may benefit from the concise overview and narrative and tabular suggestions provided.
Balter, Max L; Chen, Alvin I; Fromholtz, Alex; Gorshkov, Alex; Maguire, Tim J; Yarmush, Martin L
2016-10-01
Diagnostic blood testing is the most prevalent medical procedure performed in the world and forms the cornerstone of modern health care delivery. Yet blood tests are still predominantly carried out in centralized labs using large-volume samples acquired by manual venipuncture, and no end-to-end solution from blood draw to sample analysis exists today. Our group is developing a platform device that merges robotic phlebotomy with automated diagnostics to rapidly deliver patient information at the site of the blood draw. The system couples an image-guided venipuncture robot, designed to address the challenges of routine venous access, with a centrifuge-based blood analyzer to obtain quantitative measurements of hematology. In this paper, we first present the system design and architecture of the integrated device. We then perform a series of in vitro experiments to evaluate the cannulation accuracy of the system on blood vessel phantoms. Next, we assess the effects of vessel diameter, needle gauge, flow rate, and viscosity on the rate of sample collection. Finally, we demonstrate proof-of-concept of a white cell assay on the blood analyzer using in vitro human samples spiked with fluorescently labeled microbeads.
Tohyama, K
2018-05-01
The Japanese Society for Laboratory Hematology (JSLH) was launched in 2000 and has been developed by a mutual collaboration of hematologists, medical technologists, and the companies involved in hematological laboratory testing. The aim of JSLH is the progress and development of laboratory hematology by academic conferences, periodic publication of academic journal, training and education (in the meeting, the journal, or the website), promotion of the standardization of laboratory hematology, and certification of the laboratory hematology specialists. Among 3 specialized committees organized for the standardization of laboratory hematology, the standardization committee on blood cell morphology has been dealing with the various projects on peripheral/bone marrow blood cells and normal/abnormal morphology. Another independent organization, the Japanese National Research Group on idiopathic bone marrow failure syndromes (BMF), has raised the importance of the dysplasia of myelodysplastic syndromes (MDS) and has been conducting the prospective registration, central review, and follow-up study of MDS. This group recently proposed the grading system for diagnostic accuracy of MDS, and the detailed procedure of morphological diagnosis of MDS is presented in the specialized color atlas with typical photographs of various dysplasia. JSLH has also approved the grading system for diagnostic accuracy of MDS and adopted this standardized diagnostic system to the educational item for certification of the laboratory hematology specialists, aiming at a nationwidely expanding morphological evaluation of myelodysplasia. Further and significant progress in the standardization of blood cell morphology will be expected in Japan through the activity of JSLH. © 2018 John Wiley & Sons Ltd.
Hematologic manifestations of Helicobacter pylori infection
Campuzano-Maya, Germán
2014-01-01
Helicobacter pylori (H. pylori) is the most common infection in humans, with a marked disparity between developed and developing countries. Although H. pylori infections are asymptomatic in most infected individuals, they are intimately related to malignant gastric conditions such as gastric cancer and gastric mucosa-associated lymphoid tissue (MALT) lymphoma and to benign diseases such as gastritis and duodenal and gastric peptic ulcers. Since it was learned that bacteria could colonize the gastric mucosa, there have been reports in the medical literature of over 50 extragastric manifestations involving a variety medical areas of specialization. These areas include cardiology, dermatology, endocrinology, gynecology and obstetrics, hematology, pneumology, odontology, ophthalmology, otorhinolaryngology and pediatrics, and they encompass conditions with a range of clear evidence between the H. pylori infection and development of the disease. This literature review covers extragastric manifestations of H. pylori infection in the hematology field. It focuses on conditions that are included in international consensus and management guides for H. pylori infection, specifically iron deficiency, vitamin B12 (cobalamin) deficiency, immune thrombocytopenia, and MALT lymphoma. In addition, there is discussion of other conditions that are not included in international consensus and management guides on H. pylori, including auto-immune neutropenia, antiphospholipid syndrome, plasma cell dyscrasias, and other hematologic diseases. PMID:25278680
New apheresis indications in hematological disorders.
Pham, Huy P; Schwartz, Joseph
2016-11-01
Therapeutic apheresis can be used to treat many diseases. The American Society for Apheresis (ASFA) publishes Guidelines on the use of therapeutic apheresis every 3 years with the goal of providing the best available evidence for apheresis practice as well as clinical expertise. The 2016 (7th ed.) ASFA Guidelines contain 87 diseases (up from 78 in the 6th ed.) and 179 indications. This review outlines three new therapeutic apheresis indications for hematological disorders. The three new nonmalignant and nontransplant-related hematological disorders discussed are therapeutic plasma exchange procedures for hemophagocytic syndrome, hemolysis, elevated liver enzymes, and low platelets syndrome, and red blood cell exchange to prevent alloimmunization after exposure to rhesus (D)-positive red blood cells. All three indications are ASFA category III indications (i.e., optimal role of apheresis therapy is not established) with Grade 2C recommendation (weak recommendation, low-quality evidence). Although the three new therapeutic apheresis indications related to hematological disorders are ASFA category III with Grade 2C recommendations, along with other ASFA category III with Grade 2C recommendations, they may form the list of diseases for which basic, translational, and clinical research is needed to provide better evidence for clinical practice.
Belviranli, Muaz; Okudan, Nilsel; Kabak, Banu
2017-07-19
The objective of the study was to determine the effects of acute high-intensity interval training (HIIT) on hematological parameters in sedentary men. Ten healthy, non-smoker, and sedentary men aged between 18 and 24 years participated in the study. All subjects performed four Wingate tests with 4 min intervals between the tests. Blood samples were collected at pre-exercise, immediately after, 3 and 6 h after the fourth Wingate test. Hematological parameters were analyzed in these samples. The results showed that hematocrit percentage, hemoglobin values, red cell count, mean cell volume, platelet count, total white cell count, and counts of the white cell subgroups increased immediately after the acute HIIT and their values began to return to resting levels 3 h after exercise, and completely returned to resting levels 6 h after exercise. In conclusion, acute HIIT causes an inflammatory response in blood.
Nonanalytic Laboratory Automation: A Quarter Century of Progress.
Hawker, Charles D
2017-06-01
Clinical laboratory automation has blossomed since the 1989 AACC meeting, at which Dr. Masahide Sasaki first showed a western audience what his laboratory had implemented. Many diagnostics and other vendors are now offering a variety of automated options for laboratories of all sizes. Replacing manual processing and handling procedures with automation was embraced by the laboratory community because of the obvious benefits of labor savings and improvement in turnaround time and quality. Automation was also embraced by the diagnostics vendors who saw automation as a means of incorporating the analyzers purchased by their customers into larger systems in which the benefits of automation were integrated to the analyzers.This report reviews the options that are available to laboratory customers. These options include so called task-targeted automation-modules that range from single function devices that automate single tasks (e.g., decapping or aliquoting) to multifunction workstations that incorporate several of the functions of a laboratory sample processing department. The options also include total laboratory automation systems that use conveyors to link sample processing functions to analyzers and often include postanalytical features such as refrigerated storage and sample retrieval.Most importantly, this report reviews a recommended process for evaluating the need for new automation and for identifying the specific requirements of a laboratory and developing solutions that can meet those requirements. The report also discusses some of the practical considerations facing a laboratory in a new implementation and reviews the concept of machine vision to replace human inspections. © 2017 American Association for Clinical Chemistry.
Onco-hematological diagnostics by IR spectroscopy
NASA Astrophysics Data System (ADS)
Darchuk, Sergey D.; Korovina, Larisa A.; Sizov, Fiodor F.; Bebeshko, Vladimir G.
1998-10-01
Application of the infrared (IR) spectroscopy to early medical onco-hematological diagnostics, in particular to leukemia, is described. Leukemia is characterized by the orthophosphates acid (soluble) forms (HPO42-) accumulation in bone apatites. Bone hydroxyapatite contains predominantly basic PO43- nonsoluble orthophosphate. At the same time condensed forms of pyrophosphates (e.g., CaH2P3O7) in bones and especially in dried urine were found by the analysis of IR absorption spectra of persons with leukemia. It was show that the dried urine infrared quantitative absorption spectra investigations of phosphates contents make it possible to trace the dynamics of these elements contents during the leukemia progression and can serve for onco-hematological diagnostics at early stage of leukemia.
EXPOSURE TO CONCENTRATED AMBIENT AIR PARTICLES ALTERS HEMATOLOGIC INDICES IN HUMANS
Descriptions of changes in hematological indices have contested the premise that the biological effects of suspended particulate matter (PM) are restricted to the lung. Employing approximately 40 hematologic parameters reflecting blood cells, chemistries, mediators, and coagulati...
Immunotherapy in hematologic malignancies: past, present, and future.
Im, Annie; Pavletic, Steven Z
2017-04-24
The field of immunotherapy in cancer treatments has been accelerating over recent years and has entered the forefront as a leading area of ongoing research and promising therapies that have changed the treatment landscape for a variety of solid malignancies. Prior to its designation as the Science Breakthrough of the Year in 2013, cancer immunotherapy was active in the treatment of hematologic malignancies. This review provides a broad overview of the past, present, and potential future of immunotherapy in hematologic malignancies.
Hematology of the domestic ferret (Mustela putorius furo).
Smith, Stephen A; Zimmerman, Kurt; Moore, David M
2015-01-01
Pet ferrets are presented to veterinary clinics for routine care and treatment of clinical diseases and female reproductive problems. In addition to obtaining clinical history, additional diagnostic testing may be required, including hematological assessments. This article describes common blood collection methods, including venipuncture sites, volume of blood that can be safely collected, and handling of the blood. Hematological parameters for normal ferrets are provided along with a description of the morphology of ferret leukocytes to assist in performing a differential count.
Advantages and challenges in automated apatite fission track counting
NASA Astrophysics Data System (ADS)
Enkelmann, E.; Ehlers, T. A.
2012-04-01
Fission track thermochronometer data are often a core element of modern tectonic and denudation studies. Soon after the development of the fission track methods interest emerged for the developed an automated counting procedure to replace the time consuming labor of counting fission tracks under the microscope. Automated track counting became feasible in recent years with increasing improvements in computer software and hardware. One such example used in this study is the commercial automated fission track counting procedure from Autoscan Systems Pty that has been highlighted through several venues. We conducted experiments that are designed to reliably and consistently test the ability of this fully automated counting system to recognize fission tracks in apatite and a muscovite external detector. Fission tracks were analyzed in samples with a step-wise increase in sample complexity. The first set of experiments used a large (mm-size) slice of Durango apatite cut parallel to the prism plane. Second, samples with 80-200 μm large apatite grains of Fish Canyon Tuff were analyzed. This second sample set is characterized by complexities often found in apatites in different rock types. In addition to the automated counting procedure, the same samples were also analyzed using conventional counting procedures. We found for all samples that the fully automated fission track counting procedure using the Autoscan System yields a larger scatter in the fission track densities measured compared to conventional (manual) track counting. This scatter typically resulted from the false identification of tracks due surface and mineralogical defects, regardless of the image filtering procedure used. Large differences between track densities analyzed with the automated counting persisted between different grains analyzed in one sample as well as between different samples. As a result of these differences a manual correction of the fully automated fission track counts is necessary for
Xavier, Luciana; Cunha, Manuel; Gonçalves, Cristina; Teixeira, Maria dos Anjos; Coutinho, Jorge; Ribeiro, António Carlos Pinto; Lima, Margarida
2003-12-01
We describe a case of a patient with CD34+, TdT+, CD13-, CD33-, MPO- undifferentiated acute leukemia who refused chemotherapy and who achieved complete hematological remission 14 months after the diagnosis, during a short course of granulocyte-colony stimulating factor (G-CSF) for neutropenia and life threatening infection. Relapse occurred approximately one year later and G-CSF was reintroduced, being maintained for 4 months, at a dose and frequency adapted to maintain normal blood counts, a complete hematological remission being achieved again. Five months after withdrawing the G-CSF therapy a second relapse was observed; G-CSF was tried again with success, resulting in a very good hematological response that was sustained by G-CSF maintenance therapy. One year latter there was the need of increasing the doses of G-CSF in order to obtain the same hematological effect, at same time blast cells acquired a more mature CD34+, TdT-, CD13+, CD33-, MPO+ myeloid phenotype. Finally, the patient developed progressive neutropenia, anemia, thrombocytopenia and acute leukemia in spite of G-CSF therapy, dying 64 months after initial diagnosis (50 months after starting G-CSF therapy) with overt G-CSF resistant acute myeloblastic leukemia (AML), after failure of conventional induction chemotherapy.
Todd, Robert F; Gitlin, Scott D; Burns, Linda J
2004-06-15
A survey of directors of adult and pediatric hematology/oncology subspecialty training programs in the United States and Canada was conducted to assess the environment in which recruitment and training is conducted in these medical disciplines. A total of 107 program directors responded to the survey, representing 66% of internal medicine and 47% of pediatric subspecialty programs in hematology or hematology/oncology. Specific areas covered in the web-based questionnaire included the type and demographics of the training program, profile of the training program director, characteristics of the applicant pool and existing trainee recruits, characteristics of the training program environment and curricula, research productivity of trainees, and the career pathways taken by recent training program graduates (including dominant areas of clinical interest). The results of this survey show considerable heterogeneity in the recruiting practices and the environment in which subspecialty training occurs, leading the authors to recommend improvements in or a heightened attention to issues, including recruitment of minority trainees, flexibility to recruit international medical school graduates, timing of trainee acceptance, maintaining the financial support of Medicare graduation medical education (GME), training of physician scientists, organization of the continuity clinic experience, visibility of nonmalignant hematology as a career path, and level of training program director support.
HIV-associated hematologic malignancies: Experience from a Tertiary Cancer Center in India.
Reddy, Rakesh; Gogia, Ajay; Kumar, Lalit; Sharma, Atul; Bakhshi, Sameer; Sharma, Mehar C; Mallick, Saumyaranjan; Sahoo, Ranjit
2016-01-01
Data on HIV associated hematologic malignancies is sparse from India. This study attempts to analyze the spectrum and features of this disease at a tertiary cancer center in India. Retrospective study from case records of patients registered with a diagnosis of hematologic malignancy and HIV infection between January 2010 and June 2015. Thirteen cases of HIV associated hematologic malignancies were identified, six of them pediatric. HIV diagnosis was concurrent to diagnosis of cancer in 12 and preceded it in one of them. ECOG PS at presentation was >1 in all of them. All patients, except one, had B symptoms. Six of the patients had bulky disease and six are stage 4. Predominant extranodal disease was seen in 67% of them. NHL accounted for 10 of 13 patients and DLBCL-Germinal center was the most common subtype. Mean CD4+ cell count was 235/μL (range, 32-494). HAART could be given along with chemotherapy to 11 patients. Two-thirds of patients received standard doses of therapy. Chemo-toxicity required hospitalization in 58%. CR was achieved in 45% and 36% had progressive disease with first-line therapy. At the time of last follow up, 3 patients were alive with responsive disease, 2 in CR and 1 in PR. None of the pediatric patients were long time responders. These malignancies were of advanced stage and higher grade. Goal of therapy, in the HAART era, is curative. Pediatric patients had dismal outcome despite good chemotherapy and HAART. There is an urgent need to improve data collection for HIV related cancers in India.
NASA Astrophysics Data System (ADS)
Nurani, L. H.; Mursyidi, A.; Widyarini, S.; Rohman, A.
2017-11-01
Doxorubicin (Dox) is known as anticancer drug commonly used for cancer treatment. Eurycoma longifolia Jack or Pasakbumi was reported to have chemopreventive effect. In cancer patients, there are some dysfunctions of blood parameter, therefore some hematologic tests are needed to monitor cancer patients. In this study, the effects of combination of ethanolic extract of E. longifolia Jack (EEE) and Dox on hematologic profiles were investigated in rats injected by DMBA. Rats were divided into eight groups. Group I was normal group; Group II, rats were treated with extract dose 100 mg/kgbw; Groups III, IV, V, VI, VII and VIII, rats were treated with Dox, DMBA, DMBA+Dox, DMBA+EEE, DMBA+Dox +EEE, and Dox+EEE, respectively. DMBA administration orally was conducted twice a week for 5 weeks. At 16th week of treatments, bloods were taken from orbitalis sinus for hematologicals profile (levels of Hb, erytrocyte, hematocrite, leukocyte, MCV, MCH, and differencial leucocyte count) measurements. These data were analyzed by one way ANOVA followed by LSD test. DMBA administration significantly decreased the hematological profiles compared to the normal group, except in lymphocyte level. Rats treated with extract and extract+Dox were able to increase the hematological profile compared to rats given by DMBA only. Based on these findings it can be concluded that the combination of EEE and Dox potentially increase hematological profile of rats given by DMBA.
Kawai, Y; Nagai, Y; Ogawa, E; Kondo, H
2017-04-01
To provide target values for the manufacturers' survey of the Japanese Society for Laboratory Hematology (JSLH), accurate standard data from healthy volunteers were needed for the five-part differential leukocyte count. To obtain such data, JSLH required an antibody panel that achieved high specificity (particularly for mononuclear cells) using simple gating procedures. We developed a flow cytometric method for determining the differential leukocyte count (JSLH-Diff) and validated it by comparison with the flow cytometric differential leukocyte count of the International Council for Standardization in Haematology (ICSH-Diff) and the manual differential count obtained by microscopy (Manual-Diff). First, the reference laboratory performed an imprecision study of JSLH-Diff and ICSH-Diff, as well as performing comparison among JSLH-Diff, Manual-Diff, and ICSH-Diff. Then two reference laboratories and seven participating laboratories performed imprecision and accuracy studies of JSLH-Diff, Manual-Diff, and ICSH-Diff. Simultaneously, six manufacturers' laboratories provided their own representative values by using automated hematology analyzers. The precision of both JSLH-Diff and ICSH-Diff methods was adequate. Comparison by the reference laboratory showed that all correlation coefficients, slopes and intercepts obtained by the JSLH-Diff, ICSH-Diff, and Manual-Diff methods conformed to the criteria. When the imprecision and accuracy of JSLH-Diff were assessed at seven laboratories, the CV% for lymphocytes, neutrophils, monocytes, eosinophils, and basophils was 0.5~0.9%, 0.3~0.7%, 1.7~2.6%, 3.0~7.9%, and 3.8~10.4%, respectively. More than 99% of CD45 positive leukocytes were identified as normal leukocytes by JSLH-Diff. When JSLH-Diff method were validated by comparison with Manual-Diff and ICSH-Diff, JSLH-Diff showed good performance as a reference method. © 2016 John Wiley & Sons Ltd.
Detection of malignancy in body fluids: a comparison of the hematology and cytology laboratories.
Jerz, Jaclyn L; Donohue, Rachel E; Mody, Rayomond R; Schwartz, Mary R; Mody, Dina R; Zieske, Arthur W
2014-05-01
Body fluids submitted to the hematology laboratory for cell counts may also be examined for the presence of malignancy. Previous studies evaluating the hematology laboratory's performance at detecting malignancy in body fluids have reached conflicting conclusions. To investigate the hematology laboratory's ability to detect malignancy in body fluids by comparison with cytology. Retrospective analysis of 414 body fluid samples during an 18-month period, with introduction of new quality assurance measures after the first 210 cases. If no concurrent cytology was ordered, results were compared with recent previous and/or subsequent cytologic, histologic, or flow cytometric diagnoses. Of the initial 210 cases, the hematology laboratory detected 3 of 13 malignancies diagnosed by concurrent cytology (23% sensitivity), with no false-positives (100% specificity). Malignancy was not identified on retrospective review of the hematology slides in the 10 discrepant cases. After the initial study, educational sessions on morphology for the medical technologists and a more thorough hematology-cytology correlation policy were implemented. The subsequent 204 hematology laboratory cases had increased sensitivity for the detection of malignancy (60%; 6 of 10). Definitive features of malignancy were seen in only one discrepant hematology laboratory slide on retrospective review. This case had not been flagged for hematopathologist review. None of the discrepancies before or after implementation of the additional quality assurance measures impacted patient care. Body fluid processing by the hematology laboratory is not optimized for the detection of malignancy. Concurrent cytologic examination is critical for the detection of malignancy, and needs to be considered as cost-saving measures are increasingly implemented.
Hakki, Morgan; Rattray, Rogan M; Press, Richard D
2015-07-01
Compared to other respiratory viruses, relatively little is known about the clinical impact of coronavirus (CoV) infection after hematopoietic stem cell transplant (HSCT) or in patients with hematologic malignancies. To characterize the role of CoV in respiratory tract infections among HSCT and hematologic malignancy patients. We conducted a retrospective review of all cases of CoV infection documented by polymerase chain reaction, (PCR)-based testing on nasopharyngeal and bronchoalveolar lavage fluid samples between June 2010 and 2013. Cases of CoV infection occurring in HSCT and hematologic malignancy patients were identified and the clinical characteristics of these cases were compared to other respiratory viruses. CoV was identified in 2.6% (n=43) of all samples analyzed (n=1661) and in 6.8% of all samples testing positive for a respiratory virus (n=631). 33 of 38 (86.8%) of patients in whom CoV was identified were HSCT and hematologic malignancy patients. Among these patients, CoV was detected in 9.7% of unique infection episodes, with only rhinovirus/enterovirus (RhV/EnV) infection being more common. Group I CoV subtypes accounted for 76.3% of cases, and 57% of infections were diagnosed between December and March. CoV infection was associated with upper respiratory tract symptoms in most patients, similar to other respiratory viruses. Possible and proven lower respiratory tract disease was less common compared to other respiratory viruses except RhV/EnV. CoV is frequently detected in HSCT and hematologic malignancy patients in whom suspicion for a respiratory viral infection exists, but is less likely to progress to lower respiratory tract disease than most other respiratory viruses. Copyright © 2015 Elsevier B.V. All rights reserved.
Casis, E; Garrido, A; Uranga, B; Vives, A; Zufiaurre, C
2001-01-01
Total laboratory automation (TLA) can be substituted in mid-size laboratories by a computer sample workflow control (virtual automation). Such a solution has been implemented in our laboratory using PSM, software developed in cooperation with Roche Diagnostics (Barcelona, Spain), to this purpose. This software is connected to the online analyzers and to the laboratory information system and is able to control and direct the samples working as an intermediate station. The only difference with TLA is the replacement of transport belts by personnel of the laboratory. The implementation of this virtual automation system has allowed us the achievement of the main advantages of TLA: workload increase (64%) with reduction in the cost per test (43%), significant reduction in the number of biochemistry primary tubes (from 8 to 2), less aliquoting (from 600 to 100 samples/day), automation of functional testing, drastic reduction of preanalytical errors (from 11.7 to 0.4% of the tubes) and better total response time for both inpatients (from up to 48 hours to up to 4 hours) and outpatients (from up to 10 days to up to 48 hours). As an additional advantage, virtual automation could be implemented without hardware investment and significant headcount reduction (15% in our lab).
ERIC Educational Resources Information Center
Karp, William
The 74th Illinois General Assembly created the Illinois Commission on Automation and Technological Progress to study and analyze the economic and social effects of automation and other technological changes on industry, commerce, agriculture, education, manpower, and society in Illinois. Commission members visited industrial plants and business…
Active B12: a rapid, automated assay for holotranscobalamin on the Abbott AxSYM analyzer.
Brady, Jeff; Wilson, Lesley; McGregor, Lynda; Valente, Edward; Orning, Lars
2008-03-01
Conventional tests for vitamin B(12) deficiency measure total serum vitamin B12, whereas only that portion of vitamin B12 carried by transcobalamin (holotranscobalamin) is metabolically active. Measurement of holotranscobalamin (holoTC) may be more diagnostically accurate for detecting B(12) deficiency that requires therapy. We developed an automated assay for holoTC that can be used on the Abbott AxSYM immunoassay analyzer. AxSYM Active B12 is a 2-step sandwich microparticle enzyme immunoassay. In step 1, a holoTC-specific antibody immobilized onto latex microparticles captures holoTC in samples of serum or plasma. In step 2, the captured holoTC is detected with a conjugate of alkaline phosphatase and antiTC antibody. Neither apoTC nor haptocorrin exhibited detectable cross-reactivity. The detection limit was < or = 0.1 pmol/L. Within-run and total imprecision (CV ranges) were 3.4%-5.1% and 6.3%-8.5%, respectively. Assay CVs were < 20% from at least 3 pmol/L to 107 pmol/L. With diluted serum samples, measured concentrations were 104%-114% of the expected values in the working range of the assay. No interference from bilirubin, hemoglobin, triglycerides, erythrocytes, rheumatoid factor, or total protein was detected at expected (abnormal) concentrations. A comparison of the AxSYM Active B12 assay with a commercial RIA for holoTC yielded the regression equation: AxSYM = 0.98RIA + 4.7 pmol/L (S(y x), 11.4 pmol/L; n = 204). Assay throughput was 45 tests/h. A 95% reference interval of 19-134 pmol/L holoTC was established with samples from 292 healthy individuals. The AxSYM Active B12 assay allows rapid, precise, sensitive, specific, and automated measurement of human holoTC in serum and plasma.
Hematology of the Domestic Ferret (Mustela putorius furo).
Smith, Stephen A; Zimmerman, Kurt; Moore, David M
2015-09-01
Pet ferrets are presented to veterinary clinics for routine care and treatment of clinical diseases and female reproductive problems. In addition to obtaining clinical history, additional diagnostic testing may be required, including hematological assessments. This article describes common blood collection methods, including venipuncture sites, volume of blood that can be safely collected, and handling of the blood. Hematological parameters for normal ferrets are provided along with a description of the morphology of ferret leukocytes to assist in performing a differential count. Copyright © 2015 Elsevier Inc. All rights reserved.
Svahn, Johanna; Bagnasco, Francesca; Cappelli, Enrico; Onofrillo, Daniela; Caruso, Silvia; Corsolini, Fabio; De Rocco, Daniela; Savoia, Anna; Longoni, Daniela; Pillon, Marta; Marra, Nicoletta; Ramenghi, Ugo; Farruggia, Piero; Locasciulli, Anna; Addari, Carmen; Cerri, Carla; Mastrodicasa, Elena; Casazza, Gabriella; Verzegnassi, Federico; Riccardi, Francesca; Haupt, Riccardo; Barone, Angelica; Cesaro, Simone; Cugno, Chiara; Dufour, Carlo
2016-07-01
We analyzed 97 Fanconi anemia patients from a clinic/biological database for genotype, somatic, and hematologic phenotype, adverse hematological events, solid tumors, and treatment. Seventy-two patients belonged to complementation group A. Eighty percent of patients presented with mild/moderate somatic phenotype and most with cytopenia. No correlation was seen between somatic/hematologic phenotype and number of missense mutations of FANCA alleles. Over follow-up, 33% of patients improved or maintained mild/moderate cytopenia or normal blood count, whereas remaining worsened cytopenia. Eleven patients developed a hematological adverse event (MDS, AML, pathological cytogenetics) and three developed solid tumors. 10 years cumulative risk of death of the whole cohort was 25.6% with median follow-up 5.8 years. In patients eligible to hematopoietic stem cell transplantation because of moderate cytopenia, mortality was significantly higher in subjects transplanted from matched unrelated donor over nontransplanted subjects, whereas there was no significant difference between matched sibling donor transplants and nontransplanted patients. In patients eligible to transplant because of severe cytopenia and clonal disease, mortality risk was not significantly different in transplanted from matched unrelated versus matched sibling donor versus nontransplanted subjects. The decision to transplant should rely on various elements including, type of donor, HLA matching, patient comorbidities, impairment, and clonal evolution of hematopoiesis. Am. J. Hematol. 91:666-671, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Paramonov, V V
2017-12-01
The main goal was to analyze the incidence of the morbidity in 1980, 1989, 2001, 2014 years and the structures of the absolute number of hematopoietic and lymphoid neoplasms cases during the period 1980-2014 on radiation contaminated and not contaminated territories in Cherkasy region. The epidemiological indecies of hematological neoplasms were analyzed on radiation con taminated and not contaminated territories in Cherkasy region during the period from 1980 to 2014. Referring the territory in Cherkasy region to radiation contaminated is based on settlements dosimetry certification of Ukraine after the Chornobyl accident. 63 settlements were enrolled to radiation contaminated areas in Cherkasy region and 11 settlements assigned as not contaminated areas. The first positions in the list of the hematological neoplasms structure and frequency among new cases during 1980-2014 on not contaminated territories in Cherkasy region occupied by lymphoid leukemia, Hodgkin's lymphoma and myeloid leukemia and on the radiation contaminated territories - chronic, acute lymphoid and myeloid leukemia and lymphoma, diffuse large cell lymphoma. In the structure of hematological neoplasms record ed on the contaminated territories in Cherkasy region, there is a smaller proportion of Hodgkin's lymphoma cases (C81) than 0.84 fold (RR = 0.84; 95 % CI = 0.75-0.93) and more than 1.15 times (RR = 1.15; 95 % CI = 1.02-1.30) other unspecified malignant lymphoid and hematopoietic neoplasms. In 2001 on the radiation contaminated terri tories in Cherkasy region increase the incidence of acute and chronic myeloid leukemia in 2.46 times (p = 0.024) observed compared to non contaminated areas there (5.30 per 100 000, 95% CI = 3.03-8.33 versus 2.15 per 100,000, 95 % CI = 0.66-3.64). It was calculated that RR of acute and chronic myeloid leukemia (C92) in 2001 on radiation contaminated areas in Cherkasy region is 1.40 (95 % CI = 1.12-1.17) and Hodgkin's lymphoma (C81) on condition ally clean areas
Fu, Jack B; Tennison, Jegy M; Rutzen-Lopez, Isabel M; Silver, Julie K; Morishita, Shinichiro; Dibaj, Seyedeh S; Bruera, Eduardo
2018-03-28
To identify the frequency and characteristics of bleeding complications during acute inpatient rehabilitation of hematologic malignancy patients with severe thrombocytopenia. Retrospective descriptive analysis. Comprehensive cancer center acute inpatient rehabilitation unit. Consecutive hematologic malignancy patients with a platelet count of less than or equal to 20,000/microliter (μL) on the day of acute inpatient rehabilitation admission from 1/1/2005 through 8/31/2016. Medical records were retrospectively analyzed for demographic, laboratory, and medical data. Patients were rehabilitated using the institutional exercise guidelines for thrombocytopenic patients. Bleeding events noted in the medical record. Out of 135 acute inpatient rehabilitation admissions, 133 unique patients were analyzed with a total of 851 inpatient rehabilitation days. The mean platelet count was 14,000/μL on the day of admission and 22,000/μL over the course of the rehabilitation admission. There were 252 days of inpatient rehabilitation where patients had less than 10,000/μL platelets. A total of 97 bleeding events were documented in 77/135 (57%) admissions. Of the 97 bleeding events, 72 (74%), 14 (14%), and 11 (11%) were considered to be of low, medium, and high severity, respectively. There were 4/97 (4%) bleeding events that were highly likely attributable to physical activity but only 1/4 was considered high severity. Bleeding rates were .09, .08, .17, and .37 for > 20,000, 15-20,000, 10-15,000, and < 10,000/μL mean platelet counts respectively (p = .003). Forty-four percent of patients were transferred back to the primary acute care service with infection being the most common reason for transfer. This study is the first to examine exercise-related bleeding complications during acute inpatient rehabilitation in severely thrombocytopenic hematologic cancer patients. Bleeding rates increased with lower platelet counts. However, using the exercise guidelines for severely
Sex chromosome loss and the pseudoautosomal region genes in hematological malignancies
Weng, Stephanie; Stoner, Samuel A.; Zhang, Dong-Er
2016-01-01
Cytogenetic aberrations, such as chromosomal translocations, aneuploidy, and amplifications, are frequently detected in hematological malignancies. For many of the common autosomal aberrations, the mechanisms underlying their roles in cancer development have been well-characterized. On the contrary, although loss of a sex chromosome is observed in a broad range of hematological malignancies, how it cooperates in disease development is less understood. Nevertheless, it has been postulated that tumor suppressor genes reside on the sex chromosomes. Although the X and Y sex chromosomes are highly divergent, the pseudoautosomal regions are homologous between both chromosomes. Here, we review what is currently known about the pseudoautosomal region genes in the hematological system. Additionally, we discuss implications for haploinsufficiency of critical pseudoautosomal region sex chromosome genes, driven by sex chromosome loss, in promoting hematological malignancies. Because mechanistic studies on disease development rely heavily on murine models, we also discuss the challenges and caveats of existing models, and propose alternatives for examining the involvement of pseudoautosomal region genes and loss of a sex chromosome in vivo. With the widespread detection of loss of a sex chromosome in different hematological malignances, the elucidation of the role of pseudoautosomal region genes in the development and progression of these diseases would be invaluable to the field. PMID:27655702
Burrell, Caitlin; Zhang, Hemin; Li, Desheng; Wang, Chengdong; Li, Caiwu; Aitken-Palmer, Copper
2017-12-01
The giant panda ( Ailuropoda melanoleuca) is a high-profile threatened species with individuals in captivity worldwide. As a result of advances in captive animal management and veterinary medicine, the ex situ giant panda population is aging, and improved understanding of age-related changes is necessary. Urine and blood samples were collected in April and July 2015 and analyzed for complete blood count, serum biochemistry, and biochemical and microscopic urine analysis for all individuals sampled ( n = 7, 7-16 yr of age) from giant panda housed at the China Research and Conservation Centre for the Giant Panda in Bifengxia, Sichuan Province, China. Hematology and serum biochemistry values were similar to those previously reported for giant panda aged 2-20 yr and to Species360 (formerly International Species Information System) values. Urine was overall dilute (urine specific gravity range: 1.001-1.021), acellular, and acidic (pH range: 6-7). This is the first report of hematologic and serum biochemistry, with associated urinalysis values, in the giant panda aged 7-16 yr.
Hematology, cytochemistry and ultrastructure of blood cells in fishing cat (Felis viverrina).
Prihirunkit, Kreangsak; Salakij, Chaleow; Apibal, Suntaree; Narkkong, Nual Anong
2007-06-01
Hematological, cytochemical and ultrastructural features of blood cells in fishing cat (Felis viverrina) were evaluated using complete blood cell counts with routine and cytochemical blood stains, and scanning and transmission electron microscopy. No statistically significant difference was found in different genders of this animal. Unique features of blood cells in this animal were identified in hematological, cytochemical and ultrastructural studies. This study contributes to broaden hematological resources in wildlife animals and provides a guideline for identification of blood cells in the fishing cat.
Integration of Diagnostic Microbiology in a Model of Total Laboratory Automation.
Da Rin, Giorgio; Zoppelletto, Maira; Lippi, Giuseppe
2016-02-01
Although automation has become widely utilized in certain areas of diagnostic testing, its adoption in diagnostic microbiology has proceeded much more slowly. To describe our real-world experience of integrating an automated instrument for diagnostic microbiology (Walk-Away Specimen Processor, WASPLab) within a model of total laboratory automation (TLA). The implementation process was divided into 2 phases. The former period, lasting approximately 6 weeks, entailed the installation of the WASPLab processor to operate as a stand-alone instrumentation, whereas the latter, lasting approximately 2 weeks, involved physical connection of the WASPLab with the automation. Using the WASPLab instrument in conjunction with the TLA model, we obtained a time savings equivalent to the work of 1.2 full-time laboratory technicians for diagnostic microbiology. The connection of WASPLab to TLA allowed its management by a generalist or clinical chemistry technician, with no need for microbiology skills on the part of either worker. Hence, diagnostic microbiology could be performed by the staff that is already using the TLA, extending their activities to include processing urgent clinical chemistry and hematology specimens. The time to result was also substantially improved. According to our experience, using the WASPLab instrument as part of a TLA in diagnostic microbiology holds great promise for optimizing laboratory workflow and improving the quality of testing. © American Society for Clinical Pathology, 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Hematology, cytochemistry and ultrastructure of blood cells in fishing cat (Felis viverrina)
Salakij, Chaleow; Apibal, Suntaree; Narkkong, Nual-Anong
2007-01-01
Hematological, cytochemical and ultrastructural features of blood cells in fishing cat (Felis viverrina) were evaluated using complete blood cell counts with routine and cytochemical blood stains, and scanning and transmission electron microscopy. No statistically significant difference was found in different genders of this animal. Unique features of blood cells in this animal were identified in hematological, cytochemical and ultrastructural studies. This study contributes to broaden hematological resources in wildlife animals and provides a guideline for identification of blood cells in the fishing cat. PMID:17519570
DCB - Cancer Immunology, Hematology, and Etiology Research
Part of NCI’s Division of Cancer Biology’s research portfolio, studies supported include the characterization of basic mechanisms relevant to anti-tumor immune responses and hematologic malignancies.
K(3)EDTA Vacuum Tubes Validation for Routine Hematological Testing.
Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Poli, Giovanni; Solero, Giovanni Pietro; Picheth, Geraldo; Guidi, Gian Cesare
2012-01-01
Background and Objective. Some in vitro diagnostic devices (e.g, blood collection vacuum tubes and syringes for blood analyses) are not validated before the quality laboratory managers decide to start using or to change the brand. Frequently, the laboratory or hospital managers select the vacuum tubes for blood collection based on cost considerations or on relevance of a brand. The aim of this study was to validate two dry K(3)EDTA vacuum tubes of different brands for routine hematological testing. Methods. Blood specimens from 100 volunteers in two different K(3)EDTA vacuum tubes were collected by a single, expert phlebotomist. The routine hematological testing was done on Advia 2120i hematology system. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P < 0.05. Results and Conclusions. Different brand's tubes evaluated can represent a clinically relevant source of variations only on mean platelet volume (MPV) and platelet distribution width (PDW). Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according to him/her technical or economical reasons for routine hematological tests.
Meeting the challenge of hematologic malignancies in sub-Saharan Africa
Wood, William A.; Lee, Stephanie J.; Shea, Thomas C.; Naresh, Kikkeri N.; Kazembe, Peter N.; Casper, Corey; Hesseling, Peter B.; Mitsuyasu, Ronald T.
2012-01-01
Cancer is a leading cause of death and disability in sub-Saharan Africa and will eclipse infectious diseases within the next several decades if current trends continue. Hematologic malignancies, including non-Hodgkin lymphoma, leukemia, Hodgkin lymphoma, and multiple myeloma, account for nearly 10% of the overall cancer burden in the region, and the incidence of non-Hodgkin lymphoma and Hodgkin lymphoma is rapidly increasing as a result of HIV. Despite an increasing burden, mechanisms for diagnosing, treating, and palliating malignant hematologic disorders are inadequate. In this review, we describe the scope of the problem, including the impact of endemic infections, such as HIV, Epstein-Barr virus, malaria, and Kaposi sarcoma–associated herpesvirus. We additionally describe current limitations in hematopathology, chemotherapy, radiotherapy, hematopoietic stem cell transplantation, and supportive care and palliation. We review contemporary treatment and outcomes of hematologic malignancies in the region and outline a clinical service and research agenda, which builds on recent global health successes combating HIV and other infectious diseases. Achieving similar progress against hematologic cancers in sub-Saharan Africa will require the sustained collaboration and advocacy of the entire global cancer community. PMID:22461494
Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children
Lee, Hye Ryun; Roh, Eun Youn; Chang, Ju Young
2016-01-01
Background Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. Methods A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. Results As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. Conclusions We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age. PMID:27374715
Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children.
Lee, Hye Ryun; Shin, Sue; Yoon, Jong Hyun; Roh, Eun Youn; Chang, Ju Young
2016-09-01
Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age.
Blanchoud, Simon; Zondag, Lisa; Lamare, Miles D; Wilson, Megan J
2017-06-01
Whole-body regeneration (WBR)-the formation of an entire adult from only a small fragment of its own tissue-is extremely rare among chordates. Exceptionally, in the colonial ascidian Botrylloides leachii (Savigny, 1816) a fully functional adult is formed from their common vascular system after ablation of all adults from the colony in just 10 d, thanks to their high blastogenetic potential. While previous studies have identified key genetic markers and morphological changes, no study has yet focused on the hematological aspects of regeneration despite the major involvement of the remaining vascular system and the contained hemocytes in this process. To dissect this process, we analyzed colony blood flow patterns using time-lapse microscopy to obtain a quantitative description of the velocity, reversal pattern, and average distance traveled by hemocytes. We also observed that flows present during regeneration are powered by temporally and spatially synchronized contractions of the terminal ampullae. In addition, we revised previous studies of B. leachii hematology as well as asexual development using histological sectioning and compared the role played by hemocytes during WBR. We found that regeneration starts with a rapid healing response characterized by hemocyte aggregation and infiltration of immunocytes, followed by increased activity of hemoblasts, recruitment of macrophage-like cells for clearing the tissues of debris, and their subsequent disappearance from the circulation concomitant with the maturation of a single regenerated adult. Overall, we provide a detailed account of the hematological properties of regenerating B. leachii colonies, providing novel lines of inquiry toward the decipherment of regeneration in chordates.
Kitchen, Steve; Woolley, Anita
2013-01-01
The Q analyzer is a recently launched fully automated photo-optical analyzer equipped with primary tube cap-piercing and capable of clotting, chromogenic, and immunoturbidometric tests. The purpose of the present study was to evaluate the performance characteristics of the Q analyzer with reagents from the instrument manufacturer. We assessed precision and throughput when performing coagulation screening tests, prothrombin time (PT)/international normalized ratio (INR), activated partial thromboplastin time (APTT), and fibrinogen assay by Clauss assay. We compared results with established reagent instrument combinations in widespread use. Precision of PT/INR and APTT was acceptable as indicated by total precision of around 3%. The time to first result was 3 min for an INR and 5 min for PT/APTT. The system produced 115 completed samples per hour when processing only INRs and 60 samples (120 results) per hour for PT/APTT combined. The sensitivity of the DG-APTT Synth/Q method to mild deficiency of factor VIII (FVIII), IX, and XI was excellent (as indicated by APTTs being prolonged above the upper limit of the reference range). The Q analyzer was associated with high precision, acceptable throughput, and good reliability. When used in combination with DG-PT reagent and manufacturer's instrument-specific international sensitivity index, the INRs obtained were accurate. The Q analyzer with DG-APTT Synth reagent demonstrated good sensitivity to isolated mild deficiency of FVIII, IX, and XI and had the advantage of relative insensitivity to mild FXII deficiency. Taken together, our data indicate that the Q hemostasis analyzer was suitable for routine use in combination with the reagents evaluated.
Asymmetric dimethylarginine in the assessment of febrile neutropenia in hematological patients.
Lappalainen, Marika; Hämäläinen, Sari; Juutilainen, Auni; Koivula, Irma; Pulkki, Kari; Jantunen, Esa
2017-04-01
Asymmetric dimethylarginine (ADMA) has been recognized as an independent prognostic factor for sepsis mortality in intensive care units. No data are available on kinetics or prognostic value of ADMA in hematological patients. We evaluated the ability of ADMA to act as a predictor for complicated course of febrile neutropenia, defined as bacteremia and/or septic shock in adult hematological patients receiving intensive chemotherapy. This prospective study included 87 adult hematological patients with febrile neutropenia after an intensive chemotherapy for acute myeloid leukemia (AML) or after an autologous stem cell transplantation (ASCT). Plasma ADMA and serum C-reactive protein (CRP) levels were measured from the onset of fever (d0) and for 2 days (d1-d2) thereafter. The levels of ADMA were stable or had only minimal changes during the study period. There was no difference between the levels at any time-point in patients having complicated course compared to those without it. On the other hand, CRP levels were significantly higher on d1 (p = 0.016) in patients with bacteremia and/or septic shock than in those without. ADMA was not able to differentiate hematological patients with a complicated course from those without complications. Elevated ADMA levels are probably associated with organ dysfunction, which is rare in this group of patients, of whom about 95% can be successfully managed at the hematology ward.
Takamura, Saori; Teraki, Yuichi
2016-04-01
Eosinophilic pustular folliculitis (EPF) occurs in patients with hematological disorders. However, clinical information about hematological disorder-associated EPF is scarce. We report two cases of EPF associated with mantle cell lymphoma and reviewed the available published work on Japanese cases. We identified a total of 23 Japanese cases, including the two cases reported here, who had hematological disorder-associated EPF. Fourteen cases were associated with treatment for hematological malignancies (transplantation-related EPF) and nine cases were associated with hematological malignancies themselves (hematological malignancy-related EPF). Although the skin eruption was clinically indistinguishable between the two subtypes, transplantation-related EPF occurred on the face and trunk of young and middle-aged men and women, whereas hematological malignancy-related EPF occurred mostly on the face of older men. Peripheral blood eosinophilia was more frequently observed in transplantation-related EPF. These observations suggest variations among patients with EPF associated with hematological disorders. © 2015 Japanese Dermatological Association.
[Centralization versus decentralization. Hematology].
Borregaard, Niels
2006-04-10
Clinical haematology is the result of teamwork among dedicated specialists in pathology, molecular diagnostics, imaging, radiotherapy and the haematologist, who in turn can focus on only a limited fraction of the various and highly complex diseases that together constitute clinical haematology. The treatment of patients should be centralized in departments large enough to permit internal subspecialization and to provide expert service focused on haematology. No more than three such hematology centers are needed in Denmark.
Guo, Ying; Shin, Ki Y; Hainley, Susan; Bruera, Eduardo; Palmer, J Lynn
2011-04-01
The aim of this study was to compare functional outcomes in asthenic patients with hematologic malignancies with those of asthenic patients with solid tumors after inpatient rehabilitation. We hypothesized that asthenic patients with hematologic malignancies are less likely than patients with solid tumors to make functional improvement after rehabilitation. The records of 60 asthenic cancer patients (30 consecutive patients with solid tumors and 30 consecutive patients with hematologic malignancies) who underwent inpatient rehabilitation at a comprehensive cancer center between October 2005 and October 2007 were retrospectively reviewed. Patients with focal neurologic deficits were excluded. All patients admitted to the inpatient rehabilitation unit received 3 hrs of more of therapy per weekday. The main outcomes included total, motor, and cognitive Functional Independence Measure (FIM) scores, hospital and rehabilitation length of stay, and FIM efficiency. The mean total FIM score significantly improved in patients with solid tumors (mean, 15; range, -6 to 38) and in patients with hematologic malignancies (mean, 17; range, -3 to 27); however, between-group differences in FIM scores were not significant (P = 0.31). The solid tumor patients were significantly older than the hematologic malignancy patients (71 ± 11 vs. 64 ± 12 yrs; P = 0.02), but the mean rehabilitation lengths of stay were the same for each group (9.5 days; P = 0.82). The mean FIM efficiency in the hematologic malignancy group was higher than that of the solid tumor group (1.9 vs.1.4; P = 0.049). Asthenic patients with solid tumors or hematologic malignancies could benefit from inpatient rehabilitation and make significant functional gain.
Park, Yu Jin; Rim, John Hoon; Yim, Jisook; Lee, Sang-Guk; Kim, Jeong-Ho
2017-08-01
The use of iodinated contrast media has grown in popularity in the past two decades, but relatively little attention has been paid to the possible interferential effects of contrast media on laboratory test results. Herein, we investigate medical contrast media interference with routine chemistry results obtained by three automated chemistry analyzers. Ten levels of pooled serum were used in the study. Two types of medical contrast media [Iopamiro (iopamidol) and Omnipaque (iohexol)] were evaluated. To evaluate the dose-dependent effects of the contrast media, iopamidol and iohexol were spiked separately into aliquots of serum for final concentrations of 1.8%, 3.6%, 5.5%, 7.3%, and 9.1%. The 28 analytes included in the routine chemistry panel were measured by using Hitachi 7600, AU5800, and Cobas c702 analyzers. We calculated the delta percentage difference (DPD) between the samples and the control, and examined dose-dependent trends. When the mean DPD values were compared with the reference cut-off criteria, the only uniformly interferential effect observed for all analyzers was in total protein with iopamidol. Two additional analytes that showed trends toward interferential effects only in few analyzers and exceeded the limits of the allowable error were the serum iron and the total CO 2 . The other combinations of analyzer and contrast showed no consistent dose-dependent propensity for change in any analyte level. Our study suggests that many of the analytes included in routine chemistry results, except total protein and serum iron, are not significantly affected by iopamidol and iohexol. These results suggest that it would be beneficial to apply a flexible medical evaluation process for patients requiring both laboratory tests and imaging studies, minimizing the need for strict regulations for sequential tests. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Cabagna Zenklusen, Mariana C; Lajmanovich, Rafael C; Attademo, Andrés M; Peltzer, Paola M; Junges, Celina M; Fiorenza Biancucci, Gabriela; Bassó, Agustín
2011-03-01
The description of amphibian hematology is scarce and most of these studies have been done in species from North America, Asia and Europe. With the purpose to obtain basic hematological information of Rhinella fernandezae, 23 blood samples from Santa Fe and Entre Rios natural reserves were studied. Blood of each individual was extracted by cardiac puncture and hemograms were carried out. Morphological and cytochemical description of blood cells were analyzed in slides and were inspected for extra and intra cellular parasites. Five leucocytes types were observed, being lymphocytes the predominant ones followed by basophiles. Heterophils and eosinophils were positive to PAS, Sudan B and peroxidase. The erythrocytes and its precursors were negative for cytochemical reactions. Micronuclei and nuclear alterations frequencies were scarce. No significant differences (p > 0.05) were observed between sexes neither in hemograms nor in blood cells morphology. Microfilarias were the only hemoparasites found with a relative low prevalence and infection intensity. The hematological characteristics studied were similar to those reported for other amphibians, suggesting that R. fernandezae individuals present optimal nutritional and immunological status.
Automatic Whistler Detector and Analyzer system: Implementation of the analyzer algorithm
NASA Astrophysics Data System (ADS)
Lichtenberger, JáNos; Ferencz, Csaba; Hamar, Daniel; Steinbach, Peter; Rodger, Craig J.; Clilverd, Mark A.; Collier, Andrew B.
2010-12-01
The full potential of whistlers for monitoring plasmaspheric electron density variations has not yet been realized. The primary reason is the vast human effort required for the analysis of whistler traces. Recently, the first part of a complete whistler analysis procedure was successfully automated, i.e., the automatic detection of whistler traces from the raw broadband VLF signal was achieved. This study describes a new algorithm developed to determine plasmaspheric electron density measurements from whistler traces, based on a Virtual (Whistler) Trace Transformation, using a 2-D fast Fourier transform transformation. This algorithm can be automated and can thus form the final step to complete an Automatic Whistler Detector and Analyzer (AWDA) system. In this second AWDA paper, the practical implementation of the Automatic Whistler Analyzer (AWA) algorithm is discussed and a feasible solution is presented. The practical implementation of the algorithm is able to track the variations of plasmasphere in quasi real time on a PC cluster with 100 CPU cores. The electron densities obtained by the AWA method can be used in investigations such as plasmasphere dynamics, ionosphere-plasmasphere coupling, or in space weather models.
42 CFR 493.849 - Condition: Hematology.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Hematology. 493.849 Section 493.849 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Performing Tests of Moderate Complexity (including the Subcategory), High Complexity, Or Any Combination of...
42 CFR 493.849 - Condition: Hematology.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Hematology. 493.849 Section 493.849 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Performing Tests of Moderate Complexity (including the Subcategory), High Complexity, Or Any Combination of...
42 CFR 493.851 - Standard; Hematology.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 5 2011-10-01 2011-10-01 false Standard; Hematology. 493.851 Section 493.851 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Performing Tests of Moderate Complexity (including the Subcategory), High Complexity, Or Any Combination of...
42 CFR 493.851 - Standard; Hematology.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 5 2010-10-01 2010-10-01 false Standard; Hematology. 493.851 Section 493.851 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Performing Tests of Moderate Complexity (including the Subcategory), High Complexity, Or Any Combination of...
Cusack, Lara; Field, Cara L; Hoopes, Lisa; McDermott, Alexa; Clauss, Tonya
2016-06-01
Though one of the most widely kept elasmobranchs in human care, the cownose ray (CNR; Rhinoptera bonasus ), remains a species with minimal published information on hematologic reference intervals. As part of a larger study investigating the health and nutrition of the CNR, this study established a preliminary data set of plasma chemistry and hematology values specific to animals recently caught from the wild and compared this data set (intake sample) to values obtained following a period of quarantine (27-40 days) in an aquarium (exit sample). Blood samples were collected from 47 wild female (n = 46) and male (n = 1) CNR caught in pound nets off the coast of North Carolina and South Carolina. Differences between intake and exit values were analyzed. Due to the preponderance of female animals, data were not analyzed for sex differences. Plasma biochemical profiles were performed and analyzed. A select number of complete blood cell counts were performed (n = 24 from 12 animals). Statistically significant differences (P < 0.05) specific to time of sampling were determined for packed cell volume, total solids, blood urea nitrogen, sodium, chloride, potassium, phosphorus, cholesterol, glucose, and aspartate aminotransferase. Values reported are a significant expansion on the existing limited data for CNRs and will serve as a reference for health assessment of individuals both in the wild and in exhibit populations.
Anastasia, Antonella; Giglio, Fabio; Mazza, Rita; Sarina, Barbara; Todisco, Elisabetta; Bramanti, Stefania; Castagna, Luca
2009-01-01
The purpose of this study was to analyse our experience of early discharge 2 days after high-dose melphalan (HDM) (Day-1) followed by peripheral blood stem cell re-infusion (Day-0) and re-admission on Day +5 in patients with hematological diseases or solid tumors. From 2000 to November 2005, seven patients received tandem Melphalan 200 mg/m(2) HDM with peripheral blood stem cells transplantation (PBSC-T), 130 a single HDM, for a total of 144 procedures. In 123 of them, patients were discharged on Day +1 for re-admission on Day +5 or earlier in the event of complications. Antibiotic prophylaxis was not used. Patients were hospitalised in positive-pressure reverse isolation room during the neutropenic period. Of the 123 procedures eligible for our mixed inpatient-outpatient management regimen, six (5%) required early re-admission for complications. Full engraftment was achieved in all cases. Median time to neutrophil count >0.5 x 10(9)/microL and >1 x 10(9)/microL were 12 and 14 days, respectively. Median time to platelet recovery (>20 x 10(9)/microL) was 13 days. Severe extra-hematological toxicities occurred in 78 (63%) patients: all had oral mucositis and five had associated diarrhoea. During hospitalisation, 94/123 (76%) experienced febrile neutropenia, 20/94 (21%) had documented infection and 74/94 (79%) were considered fever of unknown origin. Median fever duration was 1 day (range 0-11). Median duration of antibiotic treatment was 6 days (range 3-26). Median time to discharge (from Day 0) was 16 days (range 11-57). There was no mortality by on Day +100. Our experience of early discharge after HDM and PBSC-T with re-admission on Day +5 is safe and feasible with acceptable frequency of hematological and extra-hematological toxicities. The regimen allows reduced hospital stay and hence cost savings.
K3EDTA Vacuum Tubes Validation for Routine Hematological Testing
Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Poli, Giovanni; Solero, Giovanni Pietro; Picheth, Geraldo; Guidi, Gian Cesare
2012-01-01
Background and Objective. Some in vitro diagnostic devices (e.g, blood collection vacuum tubes and syringes for blood analyses) are not validated before the quality laboratory managers decide to start using or to change the brand. Frequently, the laboratory or hospital managers select the vacuum tubes for blood collection based on cost considerations or on relevance of a brand. The aim of this study was to validate two dry K3EDTA vacuum tubes of different brands for routine hematological testing. Methods. Blood specimens from 100 volunteers in two different K3EDTA vacuum tubes were collected by a single, expert phlebotomist. The routine hematological testing was done on Advia 2120i hematology system. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P < 0.05. Results and Conclusions. Different brand's tubes evaluated can represent a clinically relevant source of variations only on mean platelet volume (MPV) and platelet distribution width (PDW). Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according to him/her technical or economical reasons for routine hematological tests. PMID:22888448
Hematologic reference intervals and age effect in European Strigiformes.
Agusti Montolio, Susana; Molina López, Rafael; Cray, Carolyn; Lavín González, Santiago; Nicolás Francisco, Olga; Marco Sánchez, Ignasi; Casas-Díaz, Encarna; Cuenca Valera, Rafaela
2017-09-01
The clinical importance of hematologic testing in avian veterinary medicine is reflected in the increasing number of studies for the establishment of hematologic RIs of Strigiformes and other species. Age is an important physiologic factor in birds and the effect on hematology variable should be understood. The objective of this study was to determine baseline data of hematologic variables in 5 species of Iberian Strigiformes in different age classes. Nocturnal birds of prey were sampled at Wildlife Health Centers. Packed cell volume was determined by the microhematocrit centrifugation method, and RBC and WBC counts were determined using the direct hemocytometer count method with Natt and Herrick solution. Hemoglobin concentration was measured spectrophotometrically. The MCV, MCHC, and MHC were calculated using the standard formulas. The differential WBC count was performed by the routine microscopic evaluation of 200 cells on a blood smear manually stained with Wright stain. Thrombocyte blood count estimate was obtained from the blood film. No differences were observed between juveniles and adults for any variable evaluated in Tawny owl, Little owl, Scops owl, Long-eared owl, and Barn owl. In addition, PCV, RBC, and HGB of chicks were statistically significantly lower than in juveniles and adults, and total WBC was significantly higher in Tawny owl, Little owl, Scops owl, and Long-eared owl. Our findings provide evidence that laboratory data from chicks of Strigiformes are different compared to juveniles and adults; therefore, separate RIs were defined. © 2017 American Society for Veterinary Clinical Pathology.
Streitberg, George S; Angel, Lyndall; Sikaris, Kenneth A; Bwititi, Phillip T
2012-10-01
Pathology has developed substantially since the 1990s with the introduction of total laboratory automation (TLA), in response to workloads and the need to improve quality. TLA has enhanced core laboratories, which evolved from discipline-based laboratories. Work practices have changed, with central reception now loading samples onto the Inlet module of the TLA. It is important to continually appraise technology. This study looked at the impact of technology using a self-administered survey to seniors in clinical biochemistry in NATA GX/GY-classified laboratories in Australia. The responses were yes, no, or not applicable and are expressed as percentages of responses. Some of the questions sourced for descriptive answers. Eighty-one laboratories responded, and the locations were 63%, 33%, and 4% in capital cities, regional cities, and country towns, respectively. Forty-two percent were public and 58% private. Clinical biochemistry was in all core laboratories of various sizes, and most performed up to 20 tests per sample. Thirty percent of the 121 surveyed laboratories had plans to install an automated line. Fifty-eight percent had hematology and biochemistry instrumentations in their peripheral laboratory, and 16% had a STAT laboratory on the same site as the core laboratory. There were varied instruments in specialist laboratories, and analyzers with embedded computers were in all laboratories. Medium and large laboratories had workstations with integrated instruments, and some large laboratories had TLA. Technology evolution and rising demand for pathology services make it imperative for laboratories to embrace such changes and reorganize the laboratories to take into account point-of-care testing and the efficiencies of core laboratories and TLA.
Wernick, B; Cipriano, A; Odom, S R; MacBean, U; Mubang, R N; Wojda, T R; Liu, S; Serres, S; Evans, D C; Thomas, P G; Cook, C H; Stawicki, S P
2017-06-01
The spleen is one of the most commonly injured abdominal solid organs during blunt trauma. Modern management of splenic trauma has evolved to include non-operative therapies, including observation and angioembolization to preclude splenectomy in most cases of blunt splenic injury. Despite the shift in management strategies, relatively little is known about the hematologic changes associated with these various modalities. The aim of this study was to determine if there are significant differences in hematologic characteristics over time based on the treatment modality employed following splenic trauma. We hypothesized that alterations seen in hematologic parameters would vary between observation (OBS), embolization (EMB), and splenectomy (SPL) in the setting of splenic injury. An institutional review board-approved, retrospective study of routine hematologic indices examined data between March 2000 and December 2014 at three academic trauma centers. A convenience sample of patients with splenic trauma and admission lengths of stay >96 h was selected for inclusion, resulting in a representative sample of each sub-group (OBS, EMB, and SPL). Basic demographics and injury severity data (ISS) were abstracted. Platelet count, red blood cell (RBC) count and RBC indices, and white blood cell (WBC) count with differential were analyzed between the time of admission and a maximum of 1080 h (45 days) post-injury. Comparisons between OBS, EMB, and SPL groups were then performed using non-parametric statistical testing, with statistical significance set at p < 0.05. Data from 130 patients (40 SPL, 40 EMB, and 50 OBS) were analyzed. The median age was 40 years, with 67 % males. Median ISS was 21.5 (21 for SPL, 19 for EMB, and 22 for OBS, p = n/s) and median Glasgow Coma Scale (GCS) was 15. Median splenic injury grade varied by interventional modality (grade 4 for SPL, 3 for EMB, and 2 for OBS, p < 0.05). Inter-group comparisons demonstrated no significant differences
Gill, Amy F.; Ahsan, Muhammad H.; Lackner, Andrew A.; Veazey, Ronald S.
2012-01-01
Studies of hematologic abnormalities in HIV infected patients are confounded by a multitude of factors. A retrospective data analysis of SIV infected Rhesus macaques (RM) of Indian origin was performed to determine the prevalence of hematologic abnormalities free of these confounds. Hematologic data from rhesus macaques inoculated with SIV and without antiviral therapy were examined pre-inoculation, and throughout infection and the development of AIDS. Anemia, thrombocytopenia, lymphopenia, eosinophilia, and neutropenia all increased in prevalence with SIV infection. Significant increases in prevalence for both neutropenia and neutrophilia were also detected in SIV-infected macaques. SIV-infected macaques also had lower lymphocyte counts and increased prevalence of lymphopenia compared to non-infected subjects. The prevalence of eosinophilia was significantly increased during SIV infection. Concordance of hematologic abnormalities during SIV infection of macaques with similar changes in HIV infection of humans suggest that, like in HIV infection, hematologic abnormalities are major complications of SIV infection. PMID:22620272
Gill, Amy F; Ahsan, Muhammad H; Lackner, Andrew A; Veazey, Ronald S
2012-06-01
Studies of hematologic abnormalities in HIV-infected patients are confounded by a multitude of factors. A retrospective data analysis of simian immunodeficieny virus (SIV)-infected rhesus macaques (RM) of Indian origin was performed to determine the prevalence of hematologic abnormalities free of these confounds. Hematologic data from RM inoculated with SIV and without antiviral therapy were examined pre-inoculation, and throughout infection and the development of AIDS. Anemia, thrombocytopenia, lymphopenia, eosinophilia, and neutropenia all increased in prevalence with SIV infection. Significant increases in prevalence for both neutropenia and neutrophilia were also detected in SIV-infected macaques. SIV-infected macaques also had lower lymphocyte counts and increased prevalence of lymphopenia compared with non-infected subjects. The prevalence of eosinophilia was significantly increased during SIV infection. Concordance of hematologic abnormalities during SIV infection of macaques with similar changes in HIV infection of humans suggests that, like in HIV infection, hematologic abnormalities are major complications of SIV infection. © 2012 John Wiley & Sons A/S.
Endothelial Cell-Specific Molecule-1 in Critically Ill Patients With Hematologic Malignancy.
Zafrani, Lara; Resche-Rigon, Matthieu; De Freitas Caires, Nathalie; Gaudet, Alexandre; Mathieu, Daniel; Parmentier-Decrucq, Erika; Lemiale, Virginie; Mokart, Djamel; Pène, Frédéric; Kouatchet, Achille; Mayaux, Julien; Vincent, François; N'yunga, Martine; Bruneel, Fabrice; Rabbat, Antoine; Lebert, Christine; Perez, Pierre; Meert, Anne-Pascale; Benoit, Dominique; Darmon, Michael; Azoulay, Elie
2018-03-01
To assess whether serum concentration of endothelial cell-specific molecule-1 (Endocan) at ICU admission is associated with the use of ICU resources and outcomes in critically ill hematology patients. Prospective multicenter cohort study. Seventeen ICUs in France and Belgium. Seven hundred forty-four consecutive critically ill hematology patients; 72 critically ill septic patients without hematologic malignancy; 276 healthy subjects. None. Median total endocan concentrations were 4.46 (2.7-7.8) ng/mL. Endocan concentrations were higher in patients who had received chemotherapy before ICU admission (4.7 [2.8-8.1] ng/mL vs. 3.7 [2.5-6.3] ng/mL [p = 0.002]). In patients with acute respiratory failure, endocan levels were increased in patients with drug-induced pulmonary toxicity compared with other etiologies (p = 0.038). Total endocan levels higher than 4.46 ng/mL were associated with a higher cumulative probability of renal replacement therapy requirement (p = 0.006), a higher requirement of mechanical ventilation (p = 0.01) and a higher requirement of vasopressors throughout ICU stay (p < 0.0001). By multivariate analysis, total endocan levels at admission were independently associated with ICU mortality (odds ratios, 1.39; 95% CI, 1.06-1.83; p = 0.018). The predictive value of endocan peptide fragments of 14 kDa in terms of mortality and life-sustaining therapies requirement was inferior to that of total endocan. Endocan levels were higher in critically ill hematology patients compared with healthy subjects (p < 0.0001) but lower than endocan values in critically ill septic patients without hematologic malignancy (p = 0.005) CONCLUSIONS:: Serum concentrations of endocan at admission are associated with the use of ICU resources and mortality in critically ill hematology patients. Studies to risk-stratify patients in the emergency department or in the hematology wards based on endocan concentrations to identify those likely to benefit from early ICU management
NASA Technical Reports Server (NTRS)
Frost, J. D., Jr.; Hillman, C. E., Jr.
1977-01-01
Automated self-contained portable device can be used by technicians with minimal training. Data acquired from patient at remote site are transmitted to centralized interpretation center using conventional telephone equipment. There, diagnostic information is analyzed, and results are relayed back to remote site.
The Statistical Loop Analyzer (SLA)
NASA Technical Reports Server (NTRS)
Lindsey, W. C.
1985-01-01
The statistical loop analyzer (SLA) is designed to automatically measure the acquisition, tracking and frequency stability performance characteristics of symbol synchronizers, code synchronizers, carrier tracking loops, and coherent transponders. Automated phase lock and system level tests can also be made using the SLA. Standard baseband, carrier and spread spectrum modulation techniques can be accomodated. Through the SLA's phase error jitter and cycle slip measurements the acquisition and tracking thresholds of the unit under test are determined; any false phase and frequency lock events are statistically analyzed and reported in the SLA output in probabilistic terms. Automated signal drop out tests can be performed in order to trouble shoot algorithms and evaluate the reacquisition statistics of the unit under test. Cycle slip rates and cycle slip probabilities can be measured using the SLA. These measurements, combined with bit error probability measurements, are all that are needed to fully characterize the acquisition and tracking performance of a digital communication system.
Hematological aftermath of the radiation accident in Istanbul.
Engin, Velittin Selcuk; Tufan, Fatih; Kalayoglu Besisik, Sevgi; Engin, Gulgun; Ozturk, Mustafa; Ersoy, Suleyman
2015-01-01
The effects of radiation exposure are long-lasting. Long-term monitoring is imperative to diagnose late effects and improve our far-sightedness about possible events in the future. A radiation accident occurred in Istanbul in 1998 that resulted in mild to moderate acute radiation syndrome (ARS). In this study we aimed to investigate the changes in hematological parameters at the long-term follow-up of ARS patients. Ten adults were hospitalized after exposure to a 60Co source. Seven were diagnosed as having ARS and had severe and symptomatic pancytopenia. All of the exposed people recovered following intensive treatment. Treatment was supportive with transfusion, granulocyte-colony stimulating factor, and anti- infective management covering antifungal agents. Patients were closely monitored. Nine years after the accident, the initial and follow-up complete blood count examinations and peripheral blood smears (PBS) were comparatively evaluated by an experienced hematologist. The hematological laboratory values of the patients on admission, after treatment, and nine years after the accident were documented and compared. Biodosimetric analysis revealed that whole-body doses ranged from 1-1.9 Gy. All subjects have shown complete recovery of the hematological laboratory values after treatment. All but one of the subjects showed complete blood cell recovery. The improvement of the blood cell count of the excepted patient stalled at a mildly reduced level and his bone marrow was still hypocellular nine years after the accident; however, no malignant changes were detected. Values at admission were significantly different compared with post treatment and present values of all patients. Post treatment and follow-up values were similar. One of the patients died of lung cancer. None of the patients developed hematological malignancy. In this study, the recovery from ARS was complete after treatment. The small population, short follow-up period, and the relatively small doses
Pugia, Michael; Magbanua, Mark Jesus M; Park, John W
2017-01-01
Isolation by size using a filter membrane offers an antigen-independent method for capturing rare cells present in blood of cancer patients. Multiple cell types, including circulating tumor cells (CTCs), captured on the filter membrane can be simultaneously identified via immunocytochemistry (ICC) analysis of specific cellular biomarkers. Here, we describe an automated microfluidic filtration method combined with a liquid handling system for sequential ICC assays to detect and enumerate non-hematologic rare cells in blood.
Anorectal Complications During Neutropenic Period in Patients with Hematologic Diseases
Solmaz, Soner; Korur, Aslı; Gereklioğlu, Çiğdem; Asma, Süheyl; Büyükkurt, Nurhilal; Kasar, Mutlu; Yeral, Mahmut; Kozanoğlu, İlknur; Boğa, Can; Ozdoğu, Hakan
2016-01-01
Background Neutropenic patients are susceptible to any anorectal disease, and symptomatic anorectal disease afflicts 2–32% of oncology patients. Perianal infections are the most feared complication, considering the lack of natural defense against infectious microorganisms. When septic complications develop, the anorectal disease is potentially fatal, especially in neutropenic patients in whom mortality rates range between 11–57%. Although anorectal diseases are a frequent complication with potentially fatal outcomes among patients with hematologic diseases, sufficient data are not available in the literature. In this study, we aimed to investigate the anorectal complications developing during the neutropenic period in patients with hematologic diseases. Methods A total of 79 patients whose neutropenic period (absolute neutrophil count <500/mcL) continued for 7 days, or longer were included in the study. Results A total of 34 patients out of 79 (43%) were detected to develop anorectal complications, of them 6 (7.6%) developed an anorectal infection. The patients were characterized according to the hematological disease and its status (active or not), the type of treatment and the presence of a history of an anorectal pathology before the onset of the hematologic disease. Nineteen (24.1%) patients had the history of anorectal disturbances before diagnosis of the hematologic disease, and recurrence of an anorectal pathology was found in 14 out of 19 patients(73.7%). In addition, the overall mortality rate was higher among the patients who developed anorectal complications compared to another group (41.2% vs. 22.2%, p=0.059). Conclusion Anorectal pathology is a common complication with high recurrence rate in neutropenic patients. Perianal infections are important as they can cause life-threatening outcomes although they are relatively rare among all anorectal complications. Therefore perianal signs and symptoms should be meticulously evaluated concerning early
Economic and workflow analysis of a blood bank automated system.
Shin, Kyung-Hwa; Kim, Hyung Hoi; Chang, Chulhun L; Lee, Eun Yup
2013-07-01
This study compared the estimated costs and times required for ABO/Rh(D) typing and unexpected antibody screening using an automated system and manual methods. The total cost included direct and labor costs. Labor costs were calculated on the basis of the average operator salaries and unit values (minutes), which was the hands-on time required to test one sample. To estimate unit values, workflows were recorded on video, and the time required for each process was analyzed separately. The unit values of ABO/Rh(D) typing using the manual method were 5.65 and 8.1 min during regular and unsocial working hours, respectively. The unit value was less than 3.5 min when several samples were tested simultaneously. The unit value for unexpected antibody screening was 2.6 min. The unit values using the automated method for ABO/Rh(D) typing, unexpected antibody screening, and both simultaneously were all 1.5 min. The total cost of ABO/Rh(D) typing of only one sample using the automated analyzer was lower than that of testing only one sample using the manual technique but higher than that of testing several samples simultaneously. The total cost of unexpected antibody screening using an automated analyzer was less than that using the manual method. ABO/Rh(D) typing using an automated analyzer incurs a lower unit value and cost than that using the manual technique when only one sample is tested at a time. Unexpected antibody screening using an automated analyzer always incurs a lower unit value and cost than that using the manual technique.
Utilizing cell-based therapeutics to overcome immune evasion in hematologic malignancies.
Sun, Chuang; Dotti, Gianpietro; Savoldo, Barbara
2016-06-30
Hematologic malignancies provide a suitable testing environment for cell-based immunotherapies, which were pioneered by the development of allogeneic hematopoietic stem cell transplant. All types of cell-based therapies, from donor lymphocyte infusion to dendritic cell vaccines, and adoptive transfer of tumor-specific cytotoxic T cells and natural killer cells, have been clinically translated for hematologic malignancies. The recent success of chimeric antigen receptor-modified T lymphocytes in B-cell malignancies has stimulated the development of this approach toward other hematologic tumors. Similarly, the remarkable activity of checkpoint inhibitors as single agents has created enthusiasm for potential combinations with other cell-based immune therapies. However, tumor cells continuously develop various strategies to evade their immune-mediated elimination. Meanwhile, the recruitment of immunosuppressive cells and the release of inhibitory factors contribute to the development of a tumor microenvironment that hampers the initiation of effective immune responses or blocks the functions of immune effector cells. Understanding how tumor cells escape from immune attack and favor immunosuppression is essential for the improvement of immune cell-based therapies and the development of rational combination approaches. © 2016 by The American Society of Hematology.
Hematological disorders at birth in complicated monochorionic twins.
Verbeek, Lianne; Slaghekke, Femke; Sueters, Marieke; Middeldorp, Johanna M; Klumper, Frans J; Haak, Monique C; Oepkes, Dick; Lopriore, Enrico
2017-06-01
Monochorionic twins are at risk of severe complications including twin-twin transfusion syndrome (TTTS), twin anemia-polycythemia sequence (TAPS) and acute peripartum TTTS. The pathophysiology is based on inter-twin blood transfusion through placental vascular anastomoses. Areas covered: This review focuses on the incidence, management and outcome of neonatal hematological complications at birth in TTTS, TAPS and acute peripartum TTTS. Expert commentary: Hematological disorders are often present at birth in monochorionic twins and include acute or chronic anemia, polycythemia and thrombocytopenia. Routine measurement of complete blood counts in all complicated monochorionic twins is strongly recommended. Increased awareness on these disorders and correct diagnostic tests will lead to prompt and adequate management at birth.
Zonneveld, Rens; Molema, Grietje; Plötz, Frans B
2016-01-01
Alterations in neutrophil morphology (size, shape, and composition), mechanics (deformability), and motility (chemotaxis and migration) have been observed during sepsis. We combine summarizing features of neutrophil morphology, mechanics, and motility that change during sepsis with an investigation into their clinical utility as markers for sepsis through measurement with novel technologies. We performed an initial literature search in MEDLINE using search terms "neutrophil," "morphology," "mechanics," "dynamics," "motility," "mobility," "spreading," "polarization," "migration," and "chemotaxis." We then combined the results with "sepsis" and "septic shock." We scanned bibliographies of included articles to identify additional articles. Final selection was done after the authors reviewed recovered articles. We included articles based on their relevance for our review topic. When compared with resting conditions, sepsis causes an increase in circulating numbers of larger, more rigid neutrophils that show diminished granularity, migration, and chemotaxis. Combined measurement of these variables could provide a more complete view on neutrophil phenotype manifestation. For that purpose, sophisticated automated hematology analyzers, microscopy, and bedside microfluidic devices provide clinically feasible, high-throughput, and cost-limiting means. We propose that integration of features of neutrophil morphology, mechanics, and motility with these new analytical methods can be useful as markers for diagnosis, prognosis, and monitoring of sepsis and may even contribute to basic understanding of its pathophysiology.
Blood gases, biochemistry, and hematology of Galapagos green turtles (Chelonia mydas).
Lewbart, Gregory A; Hirschfeld, Maximilian; Denkinger, Judith; Vasco, Karla; Guevara, Nataly; García, Juan; Muñoz, Juanpablo; Lohmann, Kenneth J
2014-01-01
The green turtle, Chelonia mydas, is an endangered marine chelonian with a circum-global distribution. Reference blood parameter intervals have been published for some chelonian species, but baseline hematology, biochemical, and blood gas values are lacking from the Galapagos sea turtles. Analyses were done on blood samples drawn from 28 green turtles captured in two foraging locations on San Cristóbal Island (14 from each site). Of these turtles, 20 were immature and of unknown sex; the other eight were males (five mature, three immature). A portable blood analyzer (iSTAT) was used to obtain near immediate field results for pH, lactate, pO2, pCO2, HCO3-, Hct, Hb, Na, K, iCa, and Glu. Parameter values affected by temperature were corrected in two ways: (1) with standard formulas; and (2) with auto-corrections made by the iSTAT. The two methods yielded clinically equivalent results. Standard laboratory hematology techniques were employed for the red and white blood cell counts and the hematocrit determination, which was also compared to the hematocrit values generated by the iSTAT. Of all blood analytes, only lactate concentrations were positively correlated with body size. All other values showed no significant difference between the two sample locations nor were they correlated with body size or internal temperature. For hematocrit count, the iSTAT blood analyzer yielded results indistinguishable from those obtained with high-speed centrifugation. The values reported in this study provide baseline data that may be useful in comparisons among populations and in detecting changes in health status among Galapagos sea turtles. The findings might also be helpful in future efforts to demonstrate associations between specific biochemical parameters and disease.
Blood Gases, Biochemistry, and Hematology of Galapagos Green Turtles (Chelonia Mydas)
Lewbart, Gregory A.; Hirschfeld, Maximilian; Denkinger, Judith; Vasco, Karla; Guevara, Nataly; García, Juan; Muñoz, Juanpablo; Lohmann, Kenneth J.
2014-01-01
The green turtle, Chelonia mydas, is an endangered marine chelonian with a circum-global distribution. Reference blood parameter intervals have been published for some chelonian species, but baseline hematology, biochemical, and blood gas values are lacking from the Galapagos sea turtles. Analyses were done on blood samples drawn from 28 green turtles captured in two foraging locations on San Cristóbal Island (14 from each site). Of these turtles, 20 were immature and of unknown sex; the other eight were males (five mature, three immature). A portable blood analyzer (iSTAT) was used to obtain near immediate field results for pH, lactate, pO2, pCO2, HCO3 −, Hct, Hb, Na, K, iCa, and Glu. Parameter values affected by temperature were corrected in two ways: (1) with standard formulas; and (2) with auto-corrections made by the iSTAT. The two methods yielded clinically equivalent results. Standard laboratory hematology techniques were employed for the red and white blood cell counts and the hematocrit determination, which was also compared to the hematocrit values generated by the iSTAT. Of all blood analytes, only lactate concentrations were positively correlated with body size. All other values showed no significant difference between the two sample locations nor were they correlated with body size or internal temperature. For hematocrit count, the iSTAT blood analyzer yielded results indistinguishable from those obtained with high-speed centrifugation. The values reported in this study provide baseline data that may be useful in comparisons among populations and in detecting changes in health status among Galapagos sea turtles. The findings might also be helpful in future efforts to demonstrate associations between specific biochemical parameters and disease. PMID:24824065
Inonotosis in Patient with Hematologic Malignancy
Kwon, Mi; Guinea, Jesús; Escribano, Pilar; Jiménez, María del Carmen Martínez; Pulido, Ana; Parra, Verónica; Serrano, David; Gayoso, Jorge; Martín, José Luis Díez; Bouza, Emilio
2018-01-01
We report a lung-invasive fungal disease with possible cutaneous needle tract seeding in a patient with a febrile neutropenia caused by the Basidiomycetes mold Inonotus spp. Although rare, Inonotus spp. should be added to the list of microorganisms causing invasive fungal disease in neutropenic patients with hematologic malignancies. PMID:29260664
McGrath, Pam
2017-01-01
This article examines findings on the need for, awareness of, and critical time for referral to financial assistance for patients who have to relocate for specialist care for hematological malignancies. The study involved descriptive qualitative research based on in-depth interviews that were audio-recorded, transcribed verbatim, coded, and thematically analyzed. Forty-five hematology patients purposively selected from the client database of the Leukaemia Foundation of Queensland were interviewed for the study. The findings indicate that there is a critical period at the initial point of diagnosis and start of treatment when patients are experiencing shock, confusion, and a sense of being overwhelmed by stress, fear, and uncertainty about the future. The stress can be exacerbated by the loss of work and a period of waiting to access income (e.g., from superannuation or approval to receive a pension). For some patients, this is a critical period when individuals need support and advice to avoid long-term financial problems. However, at this point in time, many individuals do not know how to access financial advice or assistance from leading cancer supportive care organizations. The findings have practical implications to inform the work by many nurses who provide psychosocial care to hematology patients. © 2016 Wiley Periodicals, Inc.
Distant testing in laboratory hematology and flow cytometry--the Indian experience.
Das Gupta, Amar
2012-06-01
Outsourcing or sending out of patients' samples to other laboratories for hematologic investigations is a common practice these days. Preanalytic variables that alter cellular parameters and levels of analytes in transit and on storage can significantly and adversely affect interpretation of test results in hematology. Awareness of these changes is necessary to avoid misinterpretation of results that in turn could influence medical management decisions.
Oral manifestations of hematologic and nutritional diseases.
Schlosser, Bethanee J; Pirigyi, Megan; Mirowski, Ginat W
2011-02-01
Oral manifestations of hematologic and nutritional deficiencies can affect the mucous membranes, teeth, periodontal tissues, salivary glands, and perioral skin. This article reviews common oral manifestations of hematologic conditions starting with disorders of the white blood cells including cyclic hematopoiesis (cyclic neutropenia), leukemias, lymphomas, plasma cell dyscrasias, and mast cell disorders; this is followed by a discussion of the impact of red blood cell disorders including anemias and less common red blood cell dyscrasias (sickle cell disease, hemochromatosis, and congenital erythropoietic porphyria) as well as thrombocytopenia. Several nutritional deficiencies exhibit oral manifestations. The authors specifically discuss the impact of water-soluble vitamins (B2, B3, B6, B9, B12, and C), fat-soluble vitamins (A, D, and K) and the eating disorders anorexia nervosa and bulimia nervosa on the oral mucosa. Copyright © 2011 Elsevier Inc. All rights reserved.
Tsai, Hsing-Chen; Huang, Li-Min; Chang, Luan-Yin; Lee, Ping-Ing; Chen, Jong-Ming; Shao, Pei-Lan; Hsueh, Po-Ren; Sheng, Wang-Huei; Chang, Yu-Ching; Lu, Chun-Yi
2015-12-01
Central line-associated bloodstream infection (CLABSI) is a serious complication in hematology-oncology patients. This study aimed to analyze the prevalence of CLABSI and the effectiveness of antimicrobial lock therapy (ALT) in pediatric patients. BSIs of all pediatric hematology-oncology patients admitted to a children's hospital between January 2009 and December 2013 were reviewed. The United States National Healthcare Safety Network and Infectious Diseases Society of America guidelines were used to define CLABSI and catheter-related BSI (CRBSI). The incidence, laboratory and microbiology characteristics, poor outcome, and effectiveness of ALT were analyzed. There were 246 cases of CLABSI in 146 patients (mean age, 10.0 years), including 66 (26.8%) cases of CRBSI. The incidence of CLABSI was 4.49/1000 catheter-days, and the infection was responsible for 32.9% of the complications these patients developed and 9.3% of contributable mortality. Patients with acute myeloid leukemia had the highest infection density (5.36/1000 patient-days). Enterobacteriaceae (40.2%) and coagulase-negative staphylococci (CoNS; 20.7%) were the predominant pathogens. In multivariate analysis, older age, male sex, elevated C-reactive protein, acute lymphoblastic leukemia, and candidemia were associated with poor outcome. The success rate of ALT was 58.6% (17/29) for the treatment of CoNS and 78.3% (29/37) for Enterobacteriaceae infections. Patients with candidemia (n = 18) had the highest mortality (33.4%) and catheter removal rate (66.7%). Chlorhexidine as the disinfectant decreased the 1-year CLABSI rate from 13.7/1000 to 8.4/1000 catheter-days (p = 0.02). CoNS and Enterobacteriaceae are the predominant pathogens in CLABSI among pediatric hematology-oncology patients. ALT is effective and showed no significant side effect. New disinfection practice and infection control measures can decrease CLABSI. Copyright © 2014. Published by Elsevier B.V.
Williams, Loretta A; Yucel, Emre; Cortes, Jorge E; Cleeland, Charles S
2014-01-01
With the rapid development of new therapies for patients with hematological malignancies, there is an increasing need for patient report of symptom status during all phases of drug testing. The patient’s perspective on new treatments reflects treatment tolerability as well as symptom benefit, and may assist patients and clinicians in choosing treatments. Inclusion of patient-reported outcomes, more common in solid-tumor than hematological trials, provides early information about symptoms to guide decisions about appropriate dosing and supportive care needs. We provide a historical overview of the use of patient-reported outcomes and symptom assessment in solid-tumor and hematological drug development, and offer recommendations about methodological issues in the monitoring of symptoms in the drug development process in hematological clinical trials. PMID:24910769
NASA Technical Reports Server (NTRS)
1993-01-01
Under a NASA Small Business Innovation Research (SBIR) contract, Axiomatics Corporation developed a shunting Dielectric Sensor to determine the nutrient level and analyze plant nutrient solutions in the CELSS, NASA's space life support program. (CELSS is an experimental facility investigating closed-cycle plant growth and food processing for long duration manned missions.) The DiComp system incorporates a shunt electrode and is especially sensitive to changes in dielectric property changes in materials at measurements much lower than conventional sensors. The analyzer has exceptional capabilities for predicting composition of liquid streams or reactions. It measures concentrations and solids content up to 100 percent in applications like agricultural products, petrochemicals, food and beverages. The sensor is easily installed; maintenance is low, and it can be calibrated on line. The software automates data collection and analysis.
Ferrà, Christelle; Xicoy, Blanca; Castillo, Nerea; Morgades, Mireia; Juncà, Jordi; Andreo, Felipe; Millá, Fuensanta; Feliu, Evarist; Ribera, Josep-María
2017-04-07
Strategies to improve the efficiency of bronchoalveolar lavage (BAL) are needed. We conducted a study to establish the diagnostic value of BAL in patients with hematological malignancies and pulmonary infiltrates. The correlation of cytologic and flow cytometric study of BAL with the microbiological findings and the clinical evolution was determined. Seventy BAL were performed and flow cytometric study was analyzed in 23 of them. Fifty-three patients did not present any adverse event attributable to BAL. Anti-infectious therapy was modified in 64 (91%) patients. T lymphocyte count >0.3×10 9 /l in peripheral blood was associated with longer OS at 3 years (53 vs. 22%, p=.009). Higher CD4 (>20/μL) and CD8 (>35/μL) lymphocyte counts in the BAL were associated with a longer OS at 3 years: 82 vs. 21% (p=.030) and 80 vs. 23% (p=.059). Our study confirms the clinical value of BAL for treatment decision making in patients with hematological malignancies and acute respiratory failure. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
Huang, Xiao Jun; Liu, Kaiyan; Ritchie, David; Andersson, Borje; Lu, Jin; Hou, Jian; Burguera, Adolfo de la Fuente; Wang, JianXiang; Yeoh, Allen; Yan, Chenhua; Zhou, Daobin; Tan, Daryl; Kim, Dong Wook; Wu, Depei; Shpall, Elizabeth; Kornblau, Stephen; Neelapu, Sattava; Hongeng, Suradej; Li, Jianyong; Hu, Jiong; Zhang, Lian Sheng; Wang, Michael; Malhotra, Pankaj; Jiang, Qian; Qin, Yazhen; Wong, Raymond; Champlin, Richard; Hagemeister, Frederick; Westin, Jason; Iyer, Swaminathan; Mathews, Vikram; Wang, Yu; Hu, Yu; Xiao, Zhijian; Shao, Zonghong; Orlowski, Robert Z; Chim, Chor Sang; Mulligan, Stephen; Sanz, Miguel; Ozawa, Keiya; Parmar, Simrit; Issaragrisil, Surapol
2017-06-20
This report serves as a snapshot of the state-of-knowledge in the Asia Pacific (APAC) Hematology Oncology community, and establishes a baseline for longitudinal investigations to follow changes in best practices over time. The objective of this study was to understand the approach to hematologic diseases, common standards of care and best practices, issues that remain controversial or debated, and educational or resource gaps that warrant attention. We used mobile application to disseminate and distribute questionnaires to delegates during the 6th international hematologic malignancies conference hosted by the APAC Hematology Consortium at Beijing, China. User responses were collected in an anonymous fashion. We report survey results in two ways: the overall responses, and responses as stratified between Chinese physicians and "Other" represented nationalities. Overall geographical concordance in survey responses was positive and strong. Perhaps more interesting than instances of absolute agreement, these data provide a unique opportunity to identify topics in which physician knowledge or opinions diverge. We assigned questions from all modules to broad categories of: patient information; diagnosis; treatment preference; transplantation; and general knowledge/opinion. On average, we observed a geographic difference of 15% for any particular answer choice, and this was fairly constant across survey modules. These results reveal utility and need for widespread and ongoing initiatives to assess knowledge and provide evidence-based education in real time. The data will be made more valuable by longitudinal participation, such that we can monitor changes in the state of the art over time.
Baseline hematology and serum biochemistry results for Indian leopards (Panthera pardus fusca)
Shanmugam, Arun Attur; Muliya, Sanath Krishna; Deshmukh, Ajay; Suresh, Sujay; Nath, Anukul; Kalaignan, Pa; Venkataravanappa, Manjunath; Jose, Lyju
2017-01-01
Aim: The aim of the study was to establish the baseline hematology and serum biochemistry values for Indian leopards (Panthera pardus fusca), and to assess the possible variations in these parameters based on age and gender. Materials and Methods: Hemato-biochemical test reports from a total of 83 healthy leopards, carried out as part of routine health evaluation in Bannerghatta Biological Park and Manikdoh Leopard Rescue Center, were used to establish baseline hematology and serum biochemistry parameters for the subspecies. The hematological parameters considered for the analysis included hemoglobin (Hb), packed cell volume, total erythrocyte count (TEC), total leukocyte count (TLC), mean corpuscular volume (MCV), mean corpuscular Hb (MCH), and MCH concentration. The serum biochemistry parameters considered included total protein (TP), albumin, globulin, aspartate aminotransferase, alanine aminotransferase (ALT), blood urea nitrogen, creatinine, triglycerides, calcium, and phosphorus. Results: Even though few differences were observed in hematologic and biochemistry values between male and female Indian leopards, the differences were statistically not significant. Effects of age, however, were evident in relation to many hematologic and biochemical parameters. Sub-adults had significantly greater values for Hb, TEC, and TLC compared to adults and geriatric group, whereas they had significantly lower MCV and MCH compared to adults and geriatric group. Among, serum biochemistry parameters the sub-adult age group was observed to have significantly lower values for TP and ALT than adult and geriatric leopards. Conclusion: The study provides a comprehensive analysis of hematologic and biochemical parameters for Indian leopards. Baselines established here will permit better captive management of the subspecies, serve as a guide to assess the health and physiological status of the free ranging leopards, and may contribute valuable information for making effective
Chen, Haijun; Gao, Yu; Wu, Jianlei; Chen, Yingyu; Chen, Buyuan; Hu, Jianda; Zhou, Jia
2014-01-01
Despite tremendous advances in the targeted therapy for various types of hematological malignancies with successful improvements in the survival rates, emerging resistance issues are startlingly high and novel therapeutic strategies are urgently needed. In addition, chemoprevention is currently becoming an elusive goal. Plant-derived natural products have garnered considerable attention in recent years due to the potential dual functions as chemotherapeutics and dietary chemoprevention. One of the particularly ubiquitous families is the polyphenolic flavonoids. Among them, baicalin and its aglycone baicalein have been widely investigated in hematological malignancies because both of them exhibit remarkable pharmacological properties. This review focuses on the recent achievements in drug discovery research associated with baicalin and baicalein for hematological malignancy therapies. The promising anticancer activities of these two flavonoids targeting diverse signaling pathways and their potential biological mechanisms in different types of hematological malignancies, as well as the combination strategy with baicalin or baicalein as chemotherapeutic adjuvants for recent therapies in these intractable diseases are discussed. Meanwhile, the biotransformation of baicalin and baicalein and the relevant approaches to improve their bioavailability are also summarized. PMID:25128647
21 CFR 864.5350 - Microsedimentation centrifuge.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Microsedimentation centrifuge. 864.5350 Section 864.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...
21 CFR 864.5350 - Microsedimentation centrifuge.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Microsedimentation centrifuge. 864.5350 Section 864.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...
21 CFR 864.5350 - Microsedimentation centrifuge.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Microsedimentation centrifuge. 864.5350 Section 864.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...
21 CFR 864.5350 - Microsedimentation centrifuge.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Microsedimentation centrifuge. 864.5350 Section 864.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...
Knowles, Susan; Hrubec, Terry C; Smith, Stephen A; Bakal, Robert S
2006-12-01
The shortnose sturgeon, Acipenser brevirostrum, is an imperiled species distributed along the Atlantic coast of North America. Interest in replenishing wild stocks with hatchery-reared fish has created a need for accurate hematologic and biochemical reference intervals to evaluate the health of both fish raised in aquaculture systems and fish in the wild. The objective of this study was to generate hematologic and biochemistry reference intervals for healthy shortnose sturgeon. Blood samples were collected in heparinized tubes from 77 shortnose sturgeon raised in flow-through aquaculture systems. Whole blood and plasma samples were analyzed for hematologic and biochemical variables using standard techniques. Reference intervals were calculated as the central 95% (percentile) of data. Hematologic reference intervals (n = 46) were as follows: PCV 26-46%, hemoglobin 5.7-8.7 g/dL, MCV 307-520 fL, MCH 65.9-107.1 pg, MCHC 15-30 g/dL, plasma proteins (refractometry) 2.8-6.0 g/dL, RBC count 0.65-1.09 x 10(6)/microL, total WBC count 28,376-90,789/microL, small lymphocytes 9063-56,656/microL, large lymphocytes 2122-10,435/microL, neutrophils 3758-33,592/microL, monocytes 0-7137/microL, eosinophils 0-1544/microL, thrombocyte-like cells 6863-23,046/microL, thrombocytes 32,205-122,179/microL, and neutrophil:lymphocyte ratio 0.068-1.026. Plasma chemistry reference intervals (n = 77) were as follows: total protein 2.7-5.3 g/dL, albumin 0.8-1.7 g/dL, globulins 1.8-3.7 mg/dL, creatinine 0-1.4 mg/dL, total bilirubin 0-0.1 mg/dL, alkaline phosphatase 47-497 U/L, aspartate aminotransferase 90-311 U/L, sodium 124-141 mmol/L, potassium 2.9-3.7 mmol/L, chloride 106-121 mmol/L, calcium 6.6-12.1 mg/dL, magnesium 1.6-2.3 mg/dL, phosphorus 5.1-8.1 mg/dL, glucose 37-74 mg/dL, cholesterol 42-133 mg/dL, and osmolality 232-289 mOsm/kg. Reference values reported here will be useful for the early detection, identification, and monitoring of disease and sublethal conditions in cultured shortnose
Ruha, Anne-Michelle; Curry, Steven C; Albrecht, Clay; Riley, Brad; Pizon, Anthony
2011-01-01
North American rattlesnake envenomations commonly produce defibrination, coagulopathy and/or thrombocytopenia, which may be reversed following treatment with Crotalidae Polyvalent Immune Fab Ovine (FabAV). Despite initial resolution with FabAV, late onset or recurrence of venom-induced hematologic effects may occur. Time at which onset of late hematotoxicity may first be detected is unknown. The purpose of this study was to identify the incidence and time of onset of recurrent or new late hypofibrinogenemia, coagulopathy, or thrombocytopenia in a cohort of rattlesnake envenomation patients seen in outpatient follow-up after treatment with FabAV, and to report hematologic outcomes in these patients. Review of 66 charts of patients with rattlesnake envenomation who were treated with FabAV, and subsequently had outpatient follow-up evaluation at least 48 h after last FabAV, was performed. Demographic information, rattlesnake and bite characteristics, dose and timing of antivenom administration, adverse events, in-patient laboratory values, length of hospital stay, and follow-up laboratory values were collected. The primary outcome parameters were recurrent or delayed onset coagulopathy, hypofibrinogenemia, or thrombocytopenia identified no sooner than 48 h after last dose of FabAV. Prior to control of the envenomation with FabAV, 42 patients (63.6%) experienced hematologic toxicity. At follow-up, 21 patients (32%) were found to have late coagulopathy, hypofibrinogenemia, or thrombocytopenia. Of twenty-three patients (35%) with more than one follow-up visit, fifteen had normal laboratory findings at the first follow-up visit. Five of these 15 patients (8% of total study group; 33% of this subgroup) with normal hematologic studies at first follow-up exhibited late hematologic toxicity at second follow-up. Severe late hematologic toxicity developed in five of 66 (8%) patients. One patient was retreated with FabAV for late severe thrombocytopenia. Recurrent and delayed
Reference values of clinical chemistry and hematology parameters in rhesus monkeys (Macaca mulatta).
Chen, Younan; Qin, Shengfang; Ding, Yang; Wei, Lingling; Zhang, Jie; Li, Hongxia; Bu, Hong; Lu, Yanrong; Cheng, Jingqiu
2009-01-01
Rhesus monkey models are valuable to the studies of human biology. Reference values for clinical chemistry and hematology parameters of rhesus monkeys are required for proper data interpretation. Whole blood was collected from 36 healthy Chinese rhesus monkeys (Macaca mulatta) of either sex, 3 to 5 yr old. Routine chemistry and hematology parameters, and some special coagulation parameters including thromboelastograph and activities of coagulation factors were tested. We presented here the baseline values of clinical chemistry and hematology parameters in normal Chinese rhesus monkeys. These data may provide valuable information for veterinarians and investigators using rhesus monkeys in experimental studies.
Blood at 70: its roots in the history of hematology and its birth.
Coller, Barry S
2015-12-10
This year we celebrate Blood's 70th year of publication. Created from the partnership of the book publisher Henry M. Stratton and the prominent hematologist Dr William Dameshek of Tufts School of Medicine, Blood has published many papers describing major advances in the science and clinical practice of hematology. Blood's founding antedated that of the American Society of Hematology (ASH) by more than 11 years and Stratton and Dameshek helped galvanize support for the creation of ASH. In this review, I place the birth of Blood in the context of the history of hematology before 1946, emphasizing the American experience from which it emerged, and focusing on research conducted during World War II. I also provide a few milestones along Blood's 70 years of publication, including: the growth in Blood's publications, the evolution of its appearance, the countries of submission of Blood papers, current subscriptions to Blood, and the evolution of topics reported in Blood's papers. The latter provides a snapshot of the evolution of hematology as a scientific and clinical discipline and the introduction of new technology to study blood and bone marrow. Detailed descriptions of the landmark discoveries reported in Blood will appear in later papers celebrating Blood's birthday authored by past Editors-in-Chief. © 2015 by The American Society of Hematology.
Nanotechnology applications in hematological malignancies (Review)
SAMIR, AHMED; ELGAMAL, BASMA M; GABR, HALA; SABAAWY, HATEM E
2015-01-01
A major limitation to current cancer therapies is the development of therapy-related side-effects and dose limiting complications. Moreover, a better understanding of the biology of cancer cells and the mechanisms of resistance to therapy is rapidly developing. The translation of advanced knowledge and discoveries achieved at the molecular level must be supported by advanced diagnostic, therapeutic and delivery technologies to translate these discoveries into useful tools that are essential in achieving progress in the war against cancer. Nanotechnology can play an essential role in this aspect providing a transforming technology that can translate the basic and clinical findings into novel diagnostic, therapeutic and preventive tools useful in different types of cancer. Hematological malignancies represent a specific class of cancer, which attracts special attention in the applications of nanotechnology for cancer diagnosis and treatment. The aim of the present review is to elucidate the emerging applications of nanotechnology in cancer management and describe the potentials of nanotechnology in changing the key fundamental aspects of hematological malignancy diagnosis, treatment and follow-up. PMID:26134389
Elkady, Abeer; Iijima, Sayuki; Aboulfotuh, Sahar; Mostafa Ali, Elsayed; Sayed, Douaa; Abdel-Aziz, Nashwa M; Ali, Amany M; Murakami, Shuko; Isogawa, Masanori; Tanaka, Yasuhito
2017-03-28
To investigate the prevalence and virological characteristics of occult hepatitis B virus (HBV) infections in patients with hematological malignancies in South Egypt. Serum samples were collected from 165 patients with hematological malignancies to monitor titers of HBV DNA, hepatitis B surface antigen (HBsAg), and antibodies to HBV core (anti-HBc) and surface antigens. Serum samples negative for HBsAg and positive for anti-HBc were subjected to nucleic acid extraction and HBV DNA detection by real-time polymerase chain reaction. DNA sequences spanning the S region were analyzed in cases with occult HBV infection. In vitro comparative study of constructed 1.24-fold wild type and S protein mutant HBV genotype D clones was further performed. HBV DNA was detected in 23 (42.6%) of 54 patients with hematological malignancies who were HBsAg negative, but anti-HBc positive, suggesting the presence of occult HBV infection. The complete HBV genome was retrieved from 6 occult HBV patients, and P120T and S143L were detected in 3 and 2 cases, respectively. Site directed mutagenesis was done to produce 1.24-fold genotype D clones with amino acid mutations T120 and L143. The in vitro analyses revealed that a lower level of extracellular HBsAg was detected by chemiluminescence enzyme immunoassay (CLEIA) with the clone containing T120 mutation, compared with the wild type or the clone with S143L mutation despite the similar levels of extracellular and intracellular HBsAg detected by Western blot. Southern blot experiments showed that the levels of intracellular HBV DNA were not different between these clones. Occult HBV infection is common in patients with hematological malignancies and associated with P120T and S143L mutations. 120T mutation impairs the detection of HBsAg by CLEIA.
Elkady, Abeer; Iijima, Sayuki; Aboulfotuh, Sahar; Mostafa Ali, Elsayed; Sayed, Douaa; Abdel-Aziz, Nashwa M; Ali, Amany M; Murakami, Shuko; Isogawa, Masanori; Tanaka, Yasuhito
2017-01-01
AIM To investigate the prevalence and virological characteristics of occult hepatitis B virus (HBV) infections in patients with hematological malignancies in South Egypt. METHODS Serum samples were collected from 165 patients with hematological malignancies to monitor titers of HBV DNA, hepatitis B surface antigen (HBsAg), and antibodies to HBV core (anti-HBc) and surface antigens. Serum samples negative for HBsAg and positive for anti-HBc were subjected to nucleic acid extraction and HBV DNA detection by real-time polymerase chain reaction. DNA sequences spanning the S region were analyzed in cases with occult HBV infection. In vitro comparative study of constructed 1.24-fold wild type and S protein mutant HBV genotype D clones was further performed. RESULTS HBV DNA was detected in 23 (42.6%) of 54 patients with hematological malignancies who were HBsAg negative, but anti-HBc positive, suggesting the presence of occult HBV infection. The complete HBV genome was retrieved from 6 occult HBV patients, and P120T and S143L were detected in 3 and 2 cases, respectively. Site directed mutagenesis was done to produce 1.24-fold genotype D clones with amino acid mutations T120 and L143. The in vitro analyses revealed that a lower level of extracellular HBsAg was detected by chemiluminescence enzyme immunoassay (CLEIA) with the clone containing T120 mutation, compared with the wild type or the clone with S143L mutation despite the similar levels of extracellular and intracellular HBsAg detected by Western blot. Southern blot experiments showed that the levels of intracellular HBV DNA were not different between these clones. CONCLUSION Occult HBV infection is common in patients with hematological malignancies and associated with P120T and S143L mutations. 120T mutation impairs the detection of HBsAg by CLEIA. PMID:28396718
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kunos, Charles A., E-mail: charles.kunos@UHhospitals.org; Debernardo, Robert; Radivoyevitch, Tomas
Purpose: To evaluate hematological toxicity after robotic stereotactic body radiosurgery (SBRT) for treatment of women with metastatic abdominopelvic gynecologic malignancies. Methods and Materials: A total of 61 women with stage IV gynecologic malignancies treated with abdominopelvic SBRT were analyzed after ablative radiation (2400 cGy/3 divided consecutive daily doses) delivered by a robotic-armed Cyberknife SBRT system. Abdominopelvic bone marrow was identified using computed tomography-guided contouring. Fatigue and hematologic toxicities were graded by retrospective assignment of common toxicity criteria for adverse events (version 4.0). Bone marrow volume receiving 1000 cGy (V10) was tested for association with post-therapy (median 32 days [25%-75% quartile,more » 28-45 days]) white- or red-cell counts, hemoglobin levels, and platelet counts as marrow toxicity surrogates. Results: In all, 61 women undergoing abdominopelvic SBRT had a median bone marrow V10 of 2% (25%-75% quartile: 0%-8%). Fifty-seven (93%) of 61 women had received at least 1 pre-SBRT marrow-taxing chemotherapy regimen for metastatic disease. Bone marrow V10 did not associate with hematological adverse events. In all, 15 grade 2 (25%) and 2 grade 3 (3%) fatigue symptoms were self-reported among the 61 women within the first 10 days post-therapy, with fatigue resolved spontaneously in all 17 women by 30 days post-therapy. Neutropenia was not observed. Three (5%) women had a grade 1 drop in hemoglobin level to <10.0 g/dL. Single grade 1, 2, and 3 thrombocytopenias were documented in 3 women. Conclusions: Abdominopelvic SBRT provided ablative radiation dose to cancer targets without increased bone marrow toxicity. Abdominopelvic SBRT for metastatic gynecologic malignancies warrants further study.« less
Multiscale Modeling of Hematologic Disorders
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fedosov, Dmitry A.; Pivkin, Igor; Pan, Wenxiao
Parasitic infectious diseases and other hereditary hematologic disorders are often associated with major changes in the shape and viscoelastic properties of red blood cells (RBCs). Such changes can disrupt blood flow and even brain perfusion, as in the case of cerebral malaria. Modeling of these hematologic disorders requires a seamless multiscale approach, where blood cells and blood flow in the entire arterial tree are represented accurately using physiologically consistent parameters. In this chapter, we present a computational methodology based on dissipative particle dynamics (DPD) which models RBCs as well as whole blood in health and disease. DPD is a Lagrangianmore » method that can be derived from systematic coarse-graining of molecular dynamics but can scale efficiently up to small arteries and can also be used to model RBCs down to spectrin level. To this end, we present two complementary mathematical models for RBCs and describe a systematic procedure on extracting the relevant input parameters from optical tweezers and microfluidic experiments for single RBCs. We then use these validated RBC models to predict the behavior of whole healthy blood and compare with experimental results. The same procedure is applied to modeling malaria, and results for infected single RBCs and whole blood are presented.« less
Juhl, Rebecca C; Roddy, Julianna V F; Wang, Tzu-Fei; Li, Junan; Elefritz, Jessica L
2018-02-09
Aminocaproic acid is frequently used in patients with hematologic malignancy that present with thrombocytopenia with or without hemorrhage. We conducted a retrospective study to evaluate the safety of aminocaproic acid in 109 patients with hematologic malignancies. Patients were included if aminocaproic acid had been administered for at least 24 hours for the prevention or treatment of thrombocytopenic hemorrhage. Our primary outcome was thromboembolic complications defined as arterial or venous thrombotic events objectively confirmed by imaging studies. Thromboembolic complications occurred in five patients (4.6%) and all were venous thromboses. Other than the underlying malignancy, these patients also had many concurrent risk factors including indwelling central venous catheters, which could have contributed to thromboses. In conclusion, in our population of patients with a variety of hematological malignancies, aminocaproic acid does not appear to be associated with a high incidence of thromboembolic complications.
Hematological complications in children subjected to extracorporeal membrane oxygenation.
Santiago, M J; Gómez, C; Magaña, I; Muñoz, V; Saiz, P; Sánchez, A; López-Herce, J
2018-03-29
To analyze the hematological complications and need for transfusions in children receiving extracorporeal life support (ECLS). A retrospective study was carried out. A pediatric intensive care unit. Children under 18 years of age treated with ECLS between September 2006 and November 2015. None. Patient and ECLS characteristics, anticoagulation, hematological and coagulation parameters, transfusions and clinical course. A total of 100 patients (94 with heart disease) with a median age of 11 months were studied. Seventy-six patients presented bleeding. The most frequent bleeding point being the mediastinum and 39 patients required revision surgery. In the first 3days, 97% of the patients required blood transfusion (34.4ml/kg per day), 94% platelets (21.1ml/kg per day) and 90% plasma (26.6ml/kg per day). Patients who were in the postoperative period, those who were bleeding at the start of ECLS, those requiring revision surgery, those who could not suspend extracorporeal circulation, and those subjected to transthoracic cannulation required a greater volume of transfusions than the rest of the patients. Thromboembolism occurred in 14 patients and hemolysis in 33 patients. Mortality among the children who were bleeding at the start of ECLS (57.6%) was significantly higher than in the rest of the patients (37.5%) (P=0.048). Children treated with ECLS present high blood product needs. The main factors related to transfusions were postoperative period, bleeding at the start of ECLS, revision surgery, transthoracic cannulation, and the impossibility of suspending extracorporeal circulation. Children with bleeding suffered greater mortality than the rest of the patients. Copyright © 2018 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.
21 CFR 864.5400 - Coagulation instrument.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Coagulation instrument. 864.5400 Section 864.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
21 CFR 864.5400 - Coagulation instrument.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Coagulation instrument. 864.5400 Section 864.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
21 CFR 864.5400 - Coagulation instrument.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Coagulation instrument. 864.5400 Section 864.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
21 CFR 864.5400 - Coagulation instrument.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Coagulation instrument. 864.5400 Section 864.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
21 CFR 864.5400 - Coagulation instrument.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Coagulation instrument. 864.5400 Section 864.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
NASA Technical Reports Server (NTRS)
1984-01-01
Automation reuirements were developed for two manufacturing concepts: (1) Gallium Arsenide Electroepitaxial Crystal Production and Wafer Manufacturing Facility, and (2) Gallium Arsenide VLSI Microelectronics Chip Processing Facility. A functional overview of the ultimate design concept incoporating the two manufacturing facilities on the space station are provided. The concepts were selected to facilitate an in-depth analysis of manufacturing automation requirements in the form of process mechanization, teleoperation and robotics, sensors, and artificial intelligence. While the cost-effectiveness of these facilities was not analyzed, both appear entirely feasible for the year 2000 timeframe.
[Construction and application of an onboard absorption analyzer device for CDOM].
Lin, Jun-Fang; Sun, Zhao-Hua; Cao, Wen-Xi; Hu, Shui-Bo; Xu, Zhan-Tang
2013-04-01
Colored dissolved organic matter (CDOM) plays an important role in marine ecosystems. In order to solve the current problems in measurement of CDOM absorption, an automated onboard analyzer based on liquid core waveguides (Teflon AF LWCC/LCW) was constructed. This analyzer has remarkable characteristics including adjusted optical pathlength, wide measurement range, and high sensitivity. The model of filtration and injection can implement the function of automated filtration, sample injection, and LWCC cleaning. The LabVIEW software platform can efficiently control the running state of the analyzer and acquire real time data including light absorption spectra, GPS data, and CTW data. By the comparison experiments and shipboard measurements, it was proved that the analyzer was reliable and robust.
Analyzing crowdsourced ratings of speech-based take-over requests for automated driving.
Bazilinskyy, P; de Winter, J C F
2017-10-01
Take-over requests in automated driving should fit the urgency of the traffic situation. The robustness of various published research findings on the valuations of speech-based warning messages is unclear. This research aimed to establish how people value speech-based take-over requests as a function of speech rate, background noise, spoken phrase, and speaker's gender and emotional tone. By means of crowdsourcing, 2669 participants from 95 countries listened to a random 10 out of 140 take-over requests, and rated each take-over request on urgency, commandingness, pleasantness, and ease of understanding. Our results replicate several published findings, in particular that an increase in speech rate results in a monotonic increase of perceived urgency. The female voice was easier to understand than a male voice when there was a high level of background noise, a finding that contradicts the literature. Moreover, a take-over request spoken with Indian accent was found to be easier to understand by participants from India than by participants from other countries. Our results replicate effects in the literature regarding speech-based warnings, and shed new light on effects of background noise, gender, and nationality. The results may have implications for the selection of appropriate take-over requests in automated driving. Additionally, our study demonstrates the promise of crowdsourcing for testing human factors and ergonomics theories with large sample sizes. Copyright © 2017 Elsevier Ltd. All rights reserved.
BCL-2 as therapeutic target for hematological malignancies.
Perini, Guilherme Fleury; Ribeiro, Glaciano Nogueira; Pinto Neto, Jorge Vaz; Campos, Laura Tojeiro; Hamerschlak, Nelson
2018-05-11
Disruption of the physiologic balance between cell proliferation and cell death is an important step of cancer development. Increased resistance to apoptosis is a key oncogenic mechanism in several hematological malignancies and, in many cases, especially in lymphoid neoplasias, has been attributed to the upregulation of BCL-2. The BCL-2 protein is the founding member of the BCL-2 family of apoptosis regulators and was the first apoptosis modulator to be associated with cancer. The recognition of the important role played by BCL-2 for cancer development and resistance to treatment made it a relevant target for therapy for many diseases, including solid tumors and hematological neoplasias. Among the different strategies that have been developed to inhibit BCL-2, BH3-mimetics have emerged as a novel class of compounds with favorable results in different clinical settings, including chronic lymphocytic leukemia (CLL). In April 2016, the first inhibitor of BCL-2, venetoclax, was approved by the US Food and Drug Administration for the treatment of patients with CLL who have 17p deletion and had received at least one prior therapy. This review focuses on the relevance of BCL-2 for apoptosis modulation at the mitochondrial level, its potential as therapeutic target for hematological malignancies, and the results obtained with selective inhibitors belonging to the BH3-mimetics, especially venetoclax used in monotherapy or in combination with other agents.
Allo HSCT Using RIC for Hematological Diseases
2017-12-03
Acute Myelogenous Leukemia; Acute Lymphocytic Leukemia; Chronic Myelogenous Leukemia; Plasma Cell Leukemia; Myelodysplastic Syndromes; Chronic Lymphocytic Leukemia; Small Lymphocytic Lymphoma; B-Cell Lymphoma; Follicular Lymphoma; Lymphoplasmacytic Lymphoma; Mantle-Cell Lymphoma; Prolymphocytic Leukemia; Lymphoblastic Lymphoma; Burkitt's Lymphoma; Non-Hodgkin's Lymphoma; Multiple Myeloma; Myeloproliferative Syndromes; Hematological Diseases
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-04
... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-82,379] Abbott Laboratories... February 22, 2013, applicable to workers of Abbott Laboratories, Diagnostic--Hematology division, including... Clara, California location of Abbott Laboratories, Diagnostic--Hematology Division. The Department has...
Rapid identification of iron deficiency in blood donors with red cell indexes provided by Advia 120.
Radtke, Hartmut; Meyer, Tina; Kalus, Ulrich; Röcker, Lothar; Salama, Abdulgabar; Kiesewetter, Holger; Latza, Reinhard
2005-01-01
A new generation of automated hematology analyzers allows the rapid determination of various red cell (RBC) indexes, including the percentage of hypochromic mature RBCs (HYPOm) and the hemoglobin (Hb) content of reticulocytes (CHr). These indexes have not yet been validated as measures for the detection of iron deficiency in blood donors. Iron status was evaluated in a total of 1142 unselected prospective blood donors based on measurement of serum ferritin, soluble transferrin receptor, and Hb compared to RBC indexes provided by an automated hematology analyzer (Advia 120, Bayer HealthCare) including HYPOm and CHr. Assuming that the most precise measure for body iron storage is related to the logarithm of the ratio of soluble transferrin receptor to ferritin, the sensitivity of ferritin for the diagnosis of iron depletion was 89 percent compared to 57 percent for HYPOm and CHr, respectively, to 69 percent for the combination of both RBC indexes, and to 26 percent for Hb concentration. The RBC indexes HYPOm und CHr are significantly better screening measures for identification of iron depletion in blood donors than Hb.
Leung, Elaine; Dix, David; Ford, Jason; Barnard, Dorothy; McBride, Eileen
2015-11-01
Pediatric hematologists/oncologists need to be skilled clinicians, and must also be adept and knowledgeable in relevant areas of laboratory medicine. Canadian training programs in this subspecialty have a minimum requirement for 6 months of training in acquiring "relevant laboratory diagnostic skills." The Canadian pediatric hematology/oncology (PHO) national specialty society, C17, recognized the need for an assessment method in laboratory skills for fellows graduating from PHO training programs. Canadian pediatric hematologists/oncologists were surveyed regarding what were felt to be the essential laboratory-related knowledge and skills deemed necessary for graduating pediatric hematology/oncology trainees. The PHOELIX (Pediatric hematology/oncology educational laboratory in-training examination) was then developed to provide an annual formative evaluation of laboratory skills in Canadian PHO trainees. The majority of PHO respondents (89%) felt that laboratory skills are important in clinical practice. An annual formative examination including review of glass slides was implemented starting in 2010; this provides feedback regarding knowledge of laboratory medicine to both trainees and program directors (PDs). We have successfully created a formative examination that can be used to evaluate and educate trainees, as well as provide PDs with a tool to gauge the effectiveness of their laboratory training curriculum. Feedback has been positive from both trainees and PDs. © 2015 Wiley Periodicals, Inc.
Automation for deep space vehicle monitoring
NASA Technical Reports Server (NTRS)
Schwuttke, Ursula M.
1991-01-01
Information on automation for deep space vehicle monitoring is given in viewgraph form. Information is given on automation goals and strategy; the Monitor Analyzer of Real-time Voyager Engineering Link (MARVEL); intelligent input data management; decision theory for making tradeoffs; dynamic tradeoff evaluation; evaluation of anomaly detection results; evaluation of data management methods; system level analysis with cooperating expert systems; the distributed architecture of multiple expert systems; and event driven response.
Shen, Tian; Gu, Delin; Zhu, Yihua; Shi, Junwei; Xu, Dongsheng; Cao, Xingjian
2016-08-01
The morphological changes in activated neutrophils associated with antituberculosis drugs can be measured by volume, conductivity, and scatter (VCS) technology on the Coulter LH750 hematology analyzer. We conducted the current study to further validate the clinical usefulness of the neutrophil VCS parameters in predicting drug-induced neutropenia. Peripheral blood samples were collected from 52 patients with drug-induced neutropenia, 309 patients without any abnormal CBC, and 237 healthy controls. The mean neutrophil volume (MNV) with its distribution width (NDW) and the mean neutrophil scatter (MNS) were studied. We observed a significant increase in the MNV and NDW as well as a significant decrease in the MNS in neutropenia patients approximately one week prior to development of neutropenia compared to healthy controls as well as to case controls. In addition, the delta MNV and delta MNS were respectively correlated well with delta absolute neutrophil counts when neutropenia occurred. The ROC curve analyses showed that the MNV、NDW and MNS had larger areas under curves compared to conventional parameters. With a cutoff of 150.15 for the MNV, a sensitivity of 84.4% and specificity of 75.7% were achieved prior to neutropenia. The neutrophil VCS parameters may be clinically useful as potential hematological indicators for predicting antituberculosis drug-induced neutropenia. Copyright © 2016 Elsevier B.V. All rights reserved.
Pattern of hematological malignancies in adolescents and young adults in Bangladesh.
Hasan, Md Mahbub; Raheem, Enayetur; Sultana, Tanvira Afroze; Hossain, Mohammad Sorowar
2017-12-01
The adolescent and young adult (AYA) age group (15-39 years) bears distinct characteristics in terms of cancer biology, long-term health and treatment-related complications and psychosocial aspects. The overall scenario of cancer including hematological malignancies (HMs) is largely unknown in Bangladesh, where a significant proportion of people (44% of total population) belong to AYA age group. This study aims to describe the patterns of HM among AYA in the context of Bangladesh METHODS: Two previously published datasets (on hematological malignancies and childhood and adolescent cancer) were merged to construct a comprehensive dataset focusing exclusively on HMs in AYA age group. Univariate descriptive statistics were calculated and bivariate association were tested using Pearson's Chi-square test. A total of 2144 diagnosed HM related cases over a period of 2007-2014 were analyzed. Acute myeloid leukemia (AML) was the most frequent HM (35.1%) in AYAs, which was followed by acute lymphoblastic leukemia (ALL) and chronic myeloid leukemia (CML) constituting 22.7% and 20.8%, respectively. Among lymphomas, Non-Hodgkin lymphoma (NHL) constituted 13.9% of all HMs while 4.6% was for Hodgkin's lymphoma (HL). This is the first attempt to provide a glimpse on the pattern and distribution of HMs among AYA in Bangladesh. Future studies are essential to get a better insight on the epidemiology, biology, potential risk factors and treatment outcomes for the AYA age group. Copyright © 2017 Elsevier Ltd. All rights reserved.
Multidrug-resistant bacteria in hematology patients: emerging threats.
Tatarelli, Paola; Mikulska, Malgorzata
2016-06-01
Multidrug-resistant (MDR) bacteria, particularly Gram negatives, such as Enterobacteriaceae resistant to third-generation cephalosporins or carbapenems and MDR Pseudomonas aeruginosa, are increasingly frequent in hematology patients. The prevalence of different resistant species varies significantly between centers. Thus, the knowledge of local epidemiology is mandatory for deciding the most appr-opriate management protocols. In the era of increasing antibiotic resistance, empirical therapy of febrile neutropenia should be individualized. A de-escalation approach is recommended in case of severe clinical presentation in patients who are at high risk for infection with a resistant strain. Targeted therapy of an MDR Gram negative usually calls for a combination treatment, although no large randomized trials exist in this setting. Infection control measures are the cornerstone of limiting the spread of MDR pathogens in hematology units.
[Recent trends in the standardization of laboratory automation].
Tao, R; Yamashita, K
2000-10-01
Laboratory automation systems have been introduced to many clinical laboratories since early 1990s. Meanwhile, it was found that the difference in the specimen tube dimensions, specimen identification formats, specimen carrier transportation equipment architecture, electromechanical interfaces between the analyzers and the automation systems was preventing the systems from being introduced to a wider extent. To standardize the different interfaces and reduce the cost necessary for the laboratory automation, NCCLS and JCCLS started establishing standards for the laboratory automation in 1996 and 1997 respectively. NCCLS has published five proposed standards which that are expected to be approved by the end of 2000.
Evidence of selective reporting bias in hematology journals: A systematic review
Scheckel, Caleb; Hicks, Chandler; Nissen, Timothy; Leduc, Linda; Som, Mousumi; Vassar, Matt
2017-01-01
Introduction Selective reporting bias occurs when chance or selective outcome reporting rather than the intervention contributes to group differences. The prevailing concern about selective reporting bias is the possibility of results being modified towards specific conclusions. In this study, we evaluate randomized controlled trials (RCTs) published in hematology journals, a group in which selective outcome reporting has not yet been explored. Methods Our primary goal was to examine discrepancies between the reported primary and secondary outcomes in registered and published RCTs concerning hematological malignancies reported in hematology journals with a high impact factor. The secondary goals were to address whether outcome reporting discrepancies favored statistically significant outcomes, whether a pattern existed between the funding source and likelihood of outcome reporting bias, and whether temporal trends were present in outcome reporting bias. For trials with major outcome discrepancies, we contacted trialists to determine reasons for these discrepancies. Trials published between January 1, 2010 and December 31, 2015 in Blood; British Journal of Haematology; American Journal of Hematology; Leukemia; and Haematologica were included. Results Of 499 RCTs screened, 109 RCTs were included. Our analysis revealed 118 major discrepancies and 629 total discrepancies. Among the 118 discrepancies, 30 (25.4%) primary outcomes were demoted, 47 (39.8%) primary outcomes were omitted, and 30 (25.4%) primary outcomes were added. Three (2.5%) secondary outcomes were upgraded to a primary outcome. The timing of assessment for a primary outcome changed eight (6.8%) times. Thirty-one major discrepancies were published with a P-value and twenty-five (80.6%) favored statistical significance. A majority of authors whom we contacted cited a pre-planned subgroup analysis as a reason for outcome changes. Conclusion Our results suggest that outcome changes occur frequently in
Cornet, Edouard; Mullier, François; Despas, Noemie; Jacqmin, Hugues; Geara, Carole; Boubaya, Marouane; Chatelain, Bernard; Troussard, Xavier
2016-10-01
The French-Speaking Cellular Haematology Group (GFHC) recently published criteria for microscopic analysis of a blood smears when a hemogram is requested. In order to evaluate and improve these recommendations using an XN (Sysmex) analyzer, we assessed 31,836 samples categorized into two sub-groups of patients either receiving or not receiving care in the clinical hematology/oncology departments of two university hospitals. By combining the manufacturer's recommendations and the GFHC recommendations, 21.3% of samples had a positive review flag in phase 1 of our study (17,991 samples). In phase 2 (13,845 samples), increasing the immature granulocytes (IG) percentage from 5-10% as a review trigger threshold, and ignoring slides with isolated flags 'PLT HIGH' (thrombocytosis) or 'MCV LOW' (microcytosis) or 'Blast/Abn Lymph and Atypical Lymph' (blast cells/abnormal lymphocytes and atypical lymphocytes) (in the absence of abnormal cells on a previous blood smear within 72 h), enabled us to significantly reduce the number of slides reviewed from 21.3-15.0% (p < 0.0001), without loss of clinical value. This decrease occurred in both sub-groups (hematology 48.7-38.0%, non-hematology 18.3-11.7%, p < 0.0001). In conclusion, the application of the GFHC criteria adapted to XN analyzers has enabled us to optimize the hematology laboratory processes, and thus reduce the production costs and the turnaround time of hemogram results.
Mazzaro, Lisa M; Meegan, Jenny; Sarran, Delphine; Romano, Tracy A; Bonato, Vinicius; Deng, Shibing; Dunn, J Lawrence
2013-12-01
Handling, including blood collection, has often been discouraged in molting penguins because it is considered an additional stress imposed on birds already experiencing major physiologic stress associated with molting. To evaluate the degree of physiologic stress posed by molting, we compared the hematologic and plasma biochemical values and hormone levels of molting and nonmolting African penguins, Spheniscus demersus. Five male and 5 female penguins randomly chosen were given complete physical examinations, were weighed, and blood samples were taken at 7 time points before, during, and after the molt. Data were analyzed by linear mixed-model analysis of variance. Throughout the study, behavior and appetite remained normal. Catecholamine levels were highly variable within and among subjects, whereas mean corticosterone levels were significantly different between baseline, molt, and postmolt values. Significant differences from baseline values were observed in many of the hematologic analytes; however, only decreases in hematocrit and red blood cell count values were considered clinically significant. Anemia due to experimentally induced blood loss as a possible cause of the significant hematologic changes was ruled out based on results of a follow-up control study during the nonmolt season, which showed no significant changes in hematocrit level or total red blood cell counts when using similar sampling protocols, which indicates that these changes were associated with molt.
[Fertility preservation in patients with hematological malignancies].
Kanda, Yoshinobu
2015-03-01
Antineoplastic chemotherapy and irradiation affect gonadal function and may lead to infertility. Recovery of gonadal function is frequently observed after conventional chemotherapy in young patients with hematological malignancies, but conditioning regimens before hematopoietic stem cell transplantation result in permanent gonadal failure. Cryopreservation of sperm is effective for male patients, but it becomes difficult even after a single cycle of chemotherapy and therefore should be accomplished before starting chemotherapy. Embryo freezing after in vitro fertilization of harvested oocytes is an established method to preserve fertility in female patients. In addition, harvesting and freezing of unfertilized oocytes is also being evaluated in a clinical study. However, collection of good oocytes after chemotherapy is difficult. In addition, oocyte harvesting is an invasive procedure and may be associated with hemorrhage or infectious complications. Ovarian shielding during total body irradiation allows ovary preservation in most female patients, but this cannot be performed in patients with active malignancies. Strategies for gonadal function preservation should be planned before starting treatment for hematological malignancies.
A hematologic survey of captive waterfowl
Shave, H.J.; Howard, V.
1976-01-01
Hematologic parameters were studied in giant Canada geese (Branta canadensis maxima), mallard ducks (Anas platyrhynchos platyrhynchos) and various species of diving ducks at seasonal intervals throughout the year. Highest values for packed cell volume, hemoglobin content and erythrocyte counts were found in the winter and pre-nesting periods. Mean corpuscular volume and mean corpuscular hemoglobin varied inversely with these values.
Khan, Raja B; Morris, E Brannon; Pui, Ching-Hon; Hudson, Melissa M; Zhou, Yinmei; Cheng, Cheng; Ledet, Davonna S; Howard, Scott C
2014-06-01
Long-term outcomes of seizures that develop during treatment of childhood hematological malignancies have not been described. We analyzed seizure outcome in 62 children with leukemia or lymphoma treated at our institution. There was a median follow-up of 6.5 years since first seizure. Seizure etiology included intrathecal or systemic methotrexate in 24, leucoencephalopathy in 11, brain hemorrhage or thrombosis in 11, meningitis in 4, and no identifiable cause in 12. Seizures remained uncontrolled in 18, and risk factors for poor control included female sex (P = .02), no seizure control with first antiseizure drug (P = .08), and longer interval between cancer diagnosis and seizure onset (P = .09). Poor seizure control after initial antiseizure drug also predicted recurrent seizure after drug withdrawal (P = .04). In conclusion, seizures are controlled with medications in a majority of patients with hematological cancer. After a period without seizures, antiseizure drug withdrawal in appropriately selected patient has a high success rate. © The Author(s) 2013.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahmed, Awad A.; Hwang, Wei-Ting; Holliday, Emma B.
Purpose: Our purpose was to assess comparative female representation trends for trainees and full-time faculty in the academic radiation oncology and hematology oncology workforce of the United States over 3 decades. Methods and Materials: Simple linear regression models with year as the independent variable were used to determine changes in female percentage representation per year and associated 95% confidence intervals for trainees and full-time faculty in each specialty. Results: Peak representation was 48.4% (801/1654) in 2013 for hematology oncology trainees, 39.0% (585/1499) in 2014 for hematology oncology full-time faculty, 34.8% (202/581) in 2007 for radiation oncology trainees, and 27.7% (439/1584) inmore » 2015 for radiation oncology full-time faculty. Representation significantly increased for trainees and full-time faculty in both specialties at approximately 1% per year for hematology oncology trainees and full-time faculty and 0.3% per year for radiation oncology trainees and full-time faculty. Compared with radiation oncology, the rates were 3.84 and 2.94 times greater for hematology oncology trainees and full-time faculty, respectively. Conclusion: Despite increased female trainee and full-time faculty representation over time in the academic oncology physician workforce, radiation oncology is lagging behind hematology oncology, with trainees declining in recent years in radiation oncology; this suggests a de facto ceiling in female representation. Whether such issues as delayed or insufficient exposure, inadequate mentorship, or specialty competitiveness disparately affect female representation in radiation oncology compared to hematology oncology are underexplored and require continued investigation to ensure that the future oncologic physician workforce reflects the diversity of the population it serves.« less
Ahmed, Awad A; Hwang, Wei-Ting; Holliday, Emma B; Chapman, Christina H; Jagsi, Reshma; Thomas, Charles R; Deville, Curtiland
2017-05-01
Our purpose was to assess comparative female representation trends for trainees and full-time faculty in the academic radiation oncology and hematology oncology workforce of the United States over 3 decades. Simple linear regression models with year as the independent variable were used to determine changes in female percentage representation per year and associated 95% confidence intervals for trainees and full-time faculty in each specialty. Peak representation was 48.4% (801/1654) in 2013 for hematology oncology trainees, 39.0% (585/1499) in 2014 for hematology oncology full-time faculty, 34.8% (202/581) in 2007 for radiation oncology trainees, and 27.7% (439/1584) in 2015 for radiation oncology full-time faculty. Representation significantly increased for trainees and full-time faculty in both specialties at approximately 1% per year for hematology oncology trainees and full-time faculty and 0.3% per year for radiation oncology trainees and full-time faculty. Compared with radiation oncology, the rates were 3.84 and 2.94 times greater for hematology oncology trainees and full-time faculty, respectively. Despite increased female trainee and full-time faculty representation over time in the academic oncology physician workforce, radiation oncology is lagging behind hematology oncology, with trainees declining in recent years in radiation oncology; this suggests a de facto ceiling in female representation. Whether such issues as delayed or insufficient exposure, inadequate mentorship, or specialty competitiveness disparately affect female representation in radiation oncology compared to hematology oncology are underexplored and require continued investigation to ensure that the future oncologic physician workforce reflects the diversity of the population it serves. Copyright © 2017 Elsevier Inc. All rights reserved.
A wideband, high-resolution spectrum analyzer
NASA Technical Reports Server (NTRS)
Quirk, M. P.; Wilck, H. C.; Garyantes, M. F.; Grimm, M. J.
1988-01-01
A two-million-channel, 40 MHz bandwidth, digital spectrum analyzer under development at the Jet Propulsion Laboratory is described. The analyzer system will serve as a prototype processor for the sky survey portion of NASA's Search for Extraterrestrial Intelligence program and for other applications in the Deep Space Network. The analyzer digitizes an analog input, performs a 2 (sup 21) point Discrete Fourier Transform, accumulates the output power, normalizes the output to remove frequency-dependent gain, and automates simple signal detection algorithms. Due to its built-in frequency-domain processing functions and configuration flexibility, the analyzer is a very powerful tool for real-time signal analysis.
Kuo, Phillip Hsin; Avery, Ryan; Krupinski, Elizabeth; Lei, Hong; Bauer, Adam; Sherman, Scott; McMillan, Natalie; Seibyl, John; Zubal, George
2013-03-01
A fully automated objective striatal analysis (OSA) program that quantitates dopamine transporter uptake in subjects with suspected Parkinson's disease was applied to images from clinical (123)I-ioflupane studies. The striatal binding ratios or alternatively the specific binding ratio (SBR) of the lowest putamen uptake was computed, and receiver-operating-characteristic (ROC) analysis was applied to 94 subjects to determine the best discriminator using this quantitative method. Ninety-four (123)I-ioflupane SPECT scans were analyzed from patients referred to our clinical imaging department and were reconstructed using the manufacturer-supplied reconstruction and filtering parameters for the radiotracer. Three trained readers conducted independent visual interpretations and reported each case as either normal or showing dopaminergic deficit (abnormal). The same images were analyzed using the OSA software, which locates the striatal and occipital structures and places regions of interest on the caudate and putamen. Additionally, the OSA places a region of interest on the occipital region that is used to calculate the background-subtracted SBR. The lower SBR of the 2 putamen regions was taken as the quantitative report. The 33 normal (bilateral comma-shaped striata) and 61 abnormal (unilateral or bilateral dopaminergic deficit) studies were analyzed to generate ROC curves. Twenty-nine of the scans were interpreted as normal and 59 as abnormal by all 3 readers. For 12 scans, the 3 readers did not unanimously agree in their interpretations (discordant). The ROC analysis, which used the visual-majority-consensus interpretation from the readers as the gold standard, yielded an area under the curve of 0.958 when using 1.08 as the threshold SBR for the lowest putamen. The sensitivity and specificity of the automated quantitative analysis were 95% and 89%, respectively. The OSA program delivers SBR quantitative values that have a high sensitivity and specificity, compared
The PIM kinases in hematological cancers.
Alvarado, Yesid; Giles, Francis J; Swords, Ronan T
2012-02-01
The PIM genes represent a family of proto-oncogenes that encode three different serine/threonine protein kinases (PIM1, PIM2 and PIM3) with essential roles in the regulation of signal transduction cascades, which promote cell survival, proliferation and drug resistance. PIM kinases are overexpressed in several hematopoietic tumors and support in vitro and in vivo malignant cell growth and survival, through cell cycle regulation and inhibition of apoptosis. PIM kinases do not have an identified regulatory domain, which means that these proteins are constitutively active once transcribed. They appear to be critical downstream effectors of important oncoproteins and, when overexpressed, can mediate drug resistance to available agents, such as rapamycin. Recent crystallography studies reveal that, unlike other kinases, they possess a hinge region, which creates a unique binding pocket for ATP, offering a target for an increasing number of potent small-molecule PIM kinase inhibitors. Preclinical studies in models of various hematologic cancers indicate that these novel agents show promising activity and some of them are currently being evaluated in a clinical setting. In this review, we profile the PIM kinases as targets for therapeutics in hematologic malignancies.
Tah, Pei Chien; Nik Shanita, Safii; Poh, Bee Koon
2012-10-01
This study aimed to compare the nutritional status of pediatric patients with hematological malignancies and solid tumors. A total of 74 pediatric cancer patients were assessed for anthropometric status, biochemical profiles, and dietary intake. The prevalence of undernutrition was higher among patients with solid tumors as reflected in their lower dietary intakes of energy and nutrients compared with patients with hematological malignancies. Adequate dietary intake is important for pediatric cancer patients, but nurses need to pay more attention to the diets of patients with solid tumors as compared with those with hematological malignancies. © 2012, Wiley Periodicals, Inc.
Targeting MDM4 as a Novel Therapeutic Approach for Hematologic Malignancies.
Cao, Lei; Fan, Lei; Xu, Wei; Li, Jian-Yong
2015-01-01
Mouse double minute 4 (MDM4) as a member of MDM family, is an oncogene emerging as an imperative negative regulator of p53. Tumor suppressor protein p53 plays a crucial role in cell cycle arrest, apoptosis and homeostasis. It has been reported that frequent inactivation of p53 was observed in numerous human cancers including hematologic malignancies. MDM4, the newly discovered modulator of p53 protein, is frequently amplified in various solid tumors such as cutaneous melanoma, retinoblastoma and hematological malignances such as chronic lymphocytic leukemia, acute myeloid leukemia and mantle cell lymphoma. Multiple evidences implicate that over-expression of MDM4 is associated with tumor progression and poor prognosis which can be reversed by knockdown of MDM4 expression or restoration of p53 function, and support the rationale for the design of future MDM4-specific therapeutics. This article discusses and focuses on using MDM4 as a novel biomarker as well as a therapeutic target for hematologic malignancies.
NASA Astrophysics Data System (ADS)
Gorlach, Igor; Wessel, Oliver
2008-09-01
In the global automotive industry, for decades, vehicle manufacturers have continually increased the level of automation of production systems in order to be competitive. However, there is a new trend to decrease the level of automation, especially in final car assembly, for reasons of economy and flexibility. In this research, the final car assembly lines at three production sites of Volkswagen are analysed in order to determine the best level of automation for each, in terms of manufacturing costs, productivity, quality and flexibility. The case study is based on the methodology proposed by the Fraunhofer Institute. The results of the analysis indicate that fully automated assembly systems are not necessarily the best option in terms of cost, productivity and quality combined, which is attributed to high complexity of final car assembly systems; some de-automation is therefore recommended. On the other hand, the analysis shows that low automation can result in poor product quality due to reasons related to plant location, such as inadequate workers' skills, motivation, etc. Hence, the automation strategy should be formulated on the basis of analysis of all relevant aspects of the manufacturing process, such as costs, quality, productivity and flexibility in relation to the local context. A more balanced combination of automated and manual assembly operations provides better utilisation of equipment, reduces production costs and improves throughput.
Exploring communication difficulties in pediatric hematology: oncology nurses.
Citak, Ebru Akgun; Toruner, Ebru Kilicarslan; Gunes, Nebahat Bora
2013-01-01
Communication plays an important role for the well being of patients, families and also health care professionals in cancer care. Conversely, ineffective communication may cause depression, increased anxiety, hopelessness and decreased of quality life for patients, families and also nurses. This study aimed to explore communication difficulties of pediatric hematology/oncology nurses with patients and their families, as well as their suggestions about communication difficulties. It was conducted in a pediatric hematology/oncology hospital in Ankara, Turkey. Qualitative data were collected by focus groups, with 21 pediatric hematology/oncology nursing staff from three groups. Content analysis was used for data analysis. Findings were grouped in three main categories. The first category concerned communication difficulties, assessing problems in responding to questions, ineffective communication and conflicts with the patient's families. The second was about the effects of communication difficulties on nurses and the last main category involved suggestions for empowering nurses with communication difficulties, the theme being related to institutional issues. Nurses experience communication difficulties with children and their families during long hospital stays. Communication difficulties particularly increase during crisis periods, like at the time of first diagnosis, relapse, the terminal stage or on days with special meaning such as holidays. The results obtained indicate that pediatric nurses and the child/family need to be supported, especially during crisis periods. Feeling of empowerment in communication will improve the quality of care by reducing the feelings of exhaustion and incompetence in nurses.
Effects of air pollution on hematological parameters in passerine birds.
Llacuna, S; Gorriz, A; Riera, M; Nadal, J
1996-07-01
The effects of atmospheric air pollution on some hematological, and bioquimic parameters, of passerine birds were analyzed. The studies were undertaken in the area of Cercs (polluted area in Spain), where there is a coal-fired power plant that emanates SO2, NOx, and particles, and the area of St. Jaume de Frontanya (nonpolluted area) located 40 km from the area of Cercs with similar climatology, relief, and altitude, but without air pollution. The results showed that there was a significant decrease in the erythrocyte count, and an increase in erythrocyte size in specimens from the polluted area. An increase in pre-albumines and a decrease in beta-globulines in Emberiza cia was observed, while an increase in transaminases (GOT and GPT), and a decrease in weight in Turdus merula from the polluted zone was observed.
Hematology: ATG and Newton's third law of motion.
Brunstein, Claudio G
2010-01-01
Patients with hematological malignancies have a risk of developing graft-versus-host disease (GVHD) following allogeneic hematopoietic stem-cell transplantation. The addition of ATG to prophylaxis regimens decreases the incidence of GVHD without compromising overall survival in these patients.
Huysal, Kağan; Budak, Yasemin U; Karaca, Ayse Ulusoy; Aydos, Murat; Kahvecioğlu, Serdar; Bulut, Mehtap; Polat, Murat
2013-01-01
Urinary tract infection (UTI) is one of the most common types of infection. Currently, diagnosis is primarily based on microbiologic culture, which is time- and labor-consuming. The aim of this study was to assess the diagnostic accuracy of urinalysis results from UriSed (77 Electronica, Budapest, Hungary), an automated microscopic image-based sediment analyzer, in predicting positive urine cultures. We examined a total of 384 urine specimens from hospitalized patients and outpatients attending our hospital on the same day for urinalysis, dipstick tests and semi-quantitative urine culture. The urinalysis results were compared with those of conventional semiquantitative urine culture. Of 384 urinary specimens, 68 were positive for bacteriuria by culture, and were thus considered true positives. Comparison of these results with those obtained from the UriSed analyzer indicated that the analyzer had a specificity of 91.1%, a sensitivity of 47.0%, a positive predictive value (PPV) of 53.3% (95% confidence interval (CI) = 40.8-65.3), and a negative predictive value (NPV) of 88.8% (95% CI = 85.0-91.8%). The accuracy was 83.3% when the urine leukocyte parameter was used, 76.8% when bacteriuria analysis of urinary sediment was used, and 85.1% when the bacteriuria and leukocyturia parameters were combined. The presence of nitrite was the best indicator of culture positivity (99.3% specificity) but had a negative likelihood ratio of 0.7, indicating that it was not a reliable clinical test. Although the specificity of the UriSed analyzer was within acceptable limits, the sensitivity value was low. Thus, UriSed urinalysis resuIts do not accurately predict the outcome of culture.
Asleep at the automated wheel-Sleepiness and fatigue during highly automated driving.
Vogelpohl, Tobias; Kühn, Matthias; Hummel, Thomas; Vollrath, Mark
2018-03-20
Due to the lack of active involvement in the driving situation and due to monotonous driving environments drivers with automation may be prone to become fatigued faster than manual drivers (e.g. Schömig et al., 2015). However, little is known about the progression of fatigue during automated driving and its effects on the ability to take back manual control after a take-over request. In this driving simulator study with Nö=ö60 drivers we used a three factorial 2ö×ö2ö×ö12 mixed design to analyze the progression (12ö×ö5ömin; within subjects) of driver fatigue in drivers with automation compared to manual drivers (between subjects). Driver fatigue was induced as either mainly sleep related or mainly task related fatigue (between subjects). Additionally, we investigated the drivers' reactions to a take-over request in a critical driving scenario to gain insights into the ability of fatigued drivers to regain manual control and situation awareness after automated driving. Drivers in the automated driving condition exhibited facial indicators of fatigue after 15 to 35ömin of driving. Manual drivers only showed similar indicators of fatigue if they suffered from a lack of sleep and then only after a longer period of driving (approx. 40ömin). Several drivers in the automated condition closed their eyes for extended periods of time. In the driving with automation condition mean automation deactivation times after a take-over request were slower for a certain percentage (about 30%) of the drivers with a lack of sleep (Mö=ö3.2; SDö=ö2.1ös) compared to the reaction times after a long drive (Mö=ö2.4; SDö=ö0.9ös). Drivers with automation also took longer than manual drivers to first glance at the speed display after a take-over request and were more likely to stay behind a braking lead vehicle instead of overtaking it. Drivers are unable to stay alert during extended periods of automated driving without non-driving related tasks. Fatigued drivers could
Hematologic values of the yucatan miniature pig.
Parsons, A H; Wells, R E
1998-01-01
Mean values and ranges for 16 hematological parameters for healthy, young, sexually-mature Yucatan miniature swine are presented. No significant differences were observed between sexes with regard to hemograms. Comparison of observed values with those published in the literature for standard domestic and other breeds of miniature swine reveals no major differences.
Hematologic and plasma chemistry values in captive psittacine birds.
Polo, F J; Peinado, V I; Viscor, G; Palomeque, J
1998-01-01
Reference values for some hematologic parameters in 19 species and plasma chemical values in 11 species of Psittacine birds, including cockatoos, parrots, amazons, macaws, conures, and lories, were established for use in veterinary medicine. The following parameters were studied: hematocrit, hemoglobin concentration, erythrocyte number, mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, erythrocyte dimensions, leukocyte number and differential leukocyte count, glucose, urea, uric acid, cholesterol, triglycerides, creatinine, aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase, creatinine phosphokinase, lactic dehydrogenase, gamma glutamyl transpeptidase, total plasma protein, albumin, globulins, albumin-globulin ratio, sodium, potassium, calcium, magnesium, total phosphorus, chloride, and osmolality. Hematologically, the Psittacine is a very homogeneous avian group, with small differences between species. They are, however, different from other groups of birds.
Analyzing machine noise for real time maintenance
NASA Astrophysics Data System (ADS)
Yamato, Yoji; Fukumoto, Yoshifumi; Kumazaki, Hiroki
2017-02-01
Recently, IoT technologies have been progressed and applications of maintenance area are expected. However, IoT maintenance applications are not spread in Japan yet because of one-off solution of sensing and analyzing for each case, high cost to collect sensing data and insufficient maintenance automation. This paper proposes a maintenance platform which analyzes sound data in edges, analyzes only anomaly data in cloud and orders maintenance automatically to resolve existing technology problems. We also implement a sample application and compare related work.
Artificial intelligence in hematology.
Zini, Gina
2005-10-01
Artificial intelligence (AI) is a computer based science which aims to simulate human brain faculties using a computational system. A brief history of this new science goes from the creation of the first artificial neuron in 1943 to the first artificial neural network application to genetic algorithms. The potential for a similar technology in medicine has immediately been identified by scientists and researchers. The possibility to store and process all medical knowledge has made this technology very attractive to assist or even surpass clinicians in reaching a diagnosis. Applications of AI in medicine include devices applied to clinical diagnosis in neurology and cardiopulmonary diseases, as well as the use of expert or knowledge-based systems in routine clinical use for diagnosis, therapeutic management and for prognostic evaluation. Biological applications include genome sequencing or DNA gene expression microarrays, modeling gene networks, analysis and clustering of gene expression data, pattern recognition in DNA and proteins, protein structure prediction. In the field of hematology the first devices based on AI have been applied to the routine laboratory data management. New tools concern the differential diagnosis in specific diseases such as anemias, thalassemias and leukemias, based on neural networks trained with data from peripheral blood analysis. A revolution in cancer diagnosis, including the diagnosis of hematological malignancies, has been the introduction of the first microarray based and bioinformatic approach for molecular diagnosis: a systematic approach based on the monitoring of simultaneous expression of thousands of genes using DNA microarray, independently of previous biological knowledge, analysed using AI devices. Using gene profiling, the traditional diagnostic pathways move from clinical to molecular based diagnostic systems.
Netting Novel Regulators of Hematopoiesis and Hematologic Malignancies in Zebrafish.
Kwan, Wanda; North, Trista E
2017-01-01
Zebrafish are one of the preeminent model systems for the study of blood development (hematopoiesis), hematopoietic stem and progenitor cell (HSPC) biology, and hematopathology. The zebrafish hematopoietic system shares strong similarities in functional populations, genetic regulators, and niche interactions with its mammalian counterparts. These evolutionarily conserved characteristics, together with emerging technologies in live imaging, compound screening, and genetic manipulation, have been employed to successfully identify and interrogate novel regulatory mechanisms and molecular pathways that guide hematopoiesis. Significantly, perturbations in many of the key developmental signals controlling hematopoiesis are associated with hematological disorders and disease, including anemia, bone marrow failure syndromes, and leukemia. Thus, understanding the regulatory pathways controlling HSPC production and function has important clinical implications. In this review, we describe how the blood system forms and is maintained in zebrafish, with particular focus on new insights into vertebrate hematological regulation gained using this model. The interplay of factors controlling development and disease in the hematopoietic system combined with the unique attributes of the zebrafish make this a powerful platform to discover novel targets for the treatment of hematological disease. © 2017 Elsevier Inc. All rights reserved.
USDA-ARS?s Scientific Manuscript database
The objective of this study was to analyze the association between hematological parameters (CBC) and gender at stocker receiving facility arrival and the risk of subsequent clinical bovine respiratory disease (BRD) diagnosis, and (2) to determine and evaluate the accuracy of CBC parameter threshold...
Khoo, T-L; Xiros, N; Guan, F; Orellana, D; Holst, J; Joshua, D E; Rasko, J E J
2013-08-01
The CELL-DYN Emerald is a compact bench-top hematology analyzer that can be used for a three-part white cell differential analysis. To determine its utility for analysis of human and mouse samples, we evaluated this machine against the larger CELL-DYN Sapphire and Sysmex XT2000iV hematology analyzers. 120 human (normal and abnormal) and 30 mouse (normal and abnormal) samples were analyzed on both the CELL-DYN Emerald and CELL-DYN Sapphire or Sysmex XT2000iV analyzers. For mouse samples, the CELL-DYN Emerald analyzer required manual recalibration based on the histogram populations. Analysis of the CELL-DYN Emerald showed excellent precision, within accepted ranges (white cell count CV% = 2.09%; hemoglobin CV% = 1.68%; platelets CV% = 4.13%). Linearity was excellent (R² ≥ 0.99), carryover was minimal (<1%), and overall interinstrument agreement was acceptable for both human and mouse samples. Comparison between the CELL-DYN Emerald and Sapphire analyzers for human samples or Sysmex XT2000iV analyzer for mouse samples showed excellent correlation for all parameters. The CELL-DYN Emerald was generally comparable to the larger reference analyzer for both human and mouse samples. It would be suitable for use in satellite research laboratories or as a backup system in larger laboratories. © 2012 John Wiley & Sons Ltd.
Role of IL-9 and STATs in hematological malignancies (Review).
Chen, Na; Wang, Xin
2014-03-01
Although interleukin-9 (IL-9) exhibits pleiotropic functions in the immune system, it remains a well-known cytokine in hematological malignancies. Previous cell culture and animal model studies have revealed that the Janus kinase-signal transducer and activator of transcription signaling pathway, which may be activated by a number of cytokines including IL-9, is critical in hematological malignancies. The current review summarizes the characterization of the biological activities of IL-9, highlights the clearly defined roles of the cytokine, and outlines questions with regard to the functions of IL-9 that require further exploration and their downstream signaling proteins, signal transducers and activators of transcription.
Nanotechnology applications in hematological malignancies (Review).
Samir, Ahmed; Elgamal, Basma M; Gabr, Hala; Sabaawy, Hatem E
2015-09-01
A major limitation to current cancer therapies is the development of therapy-related side-effects and dose limiting complications. Moreover, a better understanding of the biology of cancer cells and the mechanisms of resistance to therapy is rapidly developing. The translation of advanced knowledge and discoveries achieved at the molecular level must be supported by advanced diagnostic, therapeutic and delivery technologies to translate these discoveries into useful tools that are essential in achieving progress in the war against cancer. Nanotechnology can play an essential role in this aspect providing a transforming technology that can translate the basic and clinical findings into novel diagnostic, therapeutic and preventive tools useful in different types of cancer. Hematological malignancies represent a specific class of cancer, which attracts special attention in the applications of nanotechnology for cancer diagnosis and treatment. The aim of the present review is to elucidate the emerging applications of nanotechnology in cancer management and describe the potentials of nanotechnology in changing the key fundamental aspects of hematological malignancy diagnosis, treatment and follow-up.
Hematology journals do not sufficiently adhere to reporting guidelines: a systematic review.
Wayant, C; Smith, C; Sims, M; Vassar, M
2017-04-01
Essentials Reporting guidelines and trial/review registration aim to limit bias in research. We systematically reviewed hematology journals to examine the use of these policies. Forty-eight percent of journals made no use of these policies. Improving the use of reporting guidelines will improve research for all stakeholders. Background Reporting guidelines and trial/review registration policies have been instituted in order to minimize bias and improve research practices. Objective The objective of this study was to investigate the policies of hematology journals concerning reporting guideline adoption and trial/review registration. Methods We performed a web-based data abstraction from the Instructions for Authors of 67 hematology journals catalogued in the Expanded Science Citation Index of the 2014 Journal Citation Reports to identify whether each journal required, recommended or made no mention of the following reporting guidelines: EQUATOR, ICMJE, CONSORT, MOOSE, QUOROM, PRISMA, STARD, STROBE, ARRIVE and CARE. We also extracted whether journals required or recommended trial or systematic review registration. We e-mailed editors three times to determine which types of studies their journal accepts. Results Forty-eight per cent (32/67) of hematology journals do not adhere to any reporting guidelines. For responding journals, the QUOROM statement, MOOSE, CARE and PROSPERO were the least often mentioned, whereas the ICMJE guidelines, CONSORT statement and general trial registration were most often mentioned. Discussion Reporting guidelines are infrequently required or recommended by hematology journals. Furthermore, few require clinical trial or systematic review database registration. A higher rate of adherence to reporting guidelines can prevent bias from entering the literature. Participation from all stakeholders, including authors and journal editors, to improve reporting guideline and policy practices is required. © 2017 International Society on Thrombosis
Neurological failure in ICU patients with hematological malignancies: A prospective cohort study.
Marzorati, Chiara; Mokart, Djamel; Pène, Frederic; Lemiale, Virginie; Kouatchet, Achille; Mayaux, Julien; Vincent, François; Nyunga, Martine; Bruneel, Fabrice; Rabbat, Antoine; Lebert, Christine; Perez, Pierre; Benoit, Dominique; Citerio, Giuseppe; Azoulay, Elie; Legriel, Stephane
2017-01-01
Epidemiological studies of neurological complications in patients with hematological malignancies are scant. The objective of the study was to identify determinants of survival in patients with hematological malignancy and neurological failure. Post hoc analysis of a prospective study of adults with hematological malignancies admitted for any reason to one of 17 university or university-affiliated participating ICUs in France and Belgium (2010-2012). The primary outcome was vital status at hospital discharge. Of the 1011 patients enrolled initially, 226 (22.4%) had neurological failure. Presenting manifestations were dominated by drowsiness or stupor (65%), coma (32%), weakness (26%), and seizures (19%). Neuroimaging, lumbar puncture, and electroencephalography were performed in 113 (50%), 73 (32%), and 63 (28%) patients, respectively. A neurosurgical biopsy was done in 1 patient. Hospital mortality was 50%. By multivariate analysis, factors independently associated with higher hospital mortality were poor performance status (odds ratio [OR], 3.99; 95%CI, 1.82-9.39; P = 0.0009), non-Hodgkin's lymphoma (OR, 2.60; 95%CI, 1.35-5.15; P = 0.005), shock (OR, 1.95; 95%CI, 1.04-3.72; P = 0.04), and respiratory failure (OR, 2.18; 95%CI, 1.14-4.25; P = 0.02); and factors independently associated with lower hospital mortality were GCS score on day 1 (OR, 0.88/point; 95%CI, 0.81-0.95; P = 0.0009) and autologous stem cell transplantation (OR, 0.25; 95%CI, 0.07-0.75; P = 0.02). In ICU patients with hematological malignancies, neurological failure is common and often fatal. Independent predictors of higher hospital mortality were type of underlying hematological malignancy, poor performance status, hemodynamic and respiratory failures, and severity of consciousness impairment. Knowledge of these risk factors might help to optimize management strategies.
Neurological failure in ICU patients with hematological malignancies: A prospective cohort study
Marzorati, Chiara; Mokart, Djamel; Pène, Frederic; Lemiale, Virginie; Kouatchet, Achille; Mayaux, Julien; Vincent, François; Nyunga, Martine; Bruneel, Fabrice; Rabbat, Antoine; Lebert, Christine; Perez, Pierre; Benoit, Dominique; Citerio, Giuseppe; Azoulay, Elie
2017-01-01
Background Epidemiological studies of neurological complications in patients with hematological malignancies are scant. The objective of the study was to identify determinants of survival in patients with hematological malignancy and neurological failure. Methods Post hoc analysis of a prospective study of adults with hematological malignancies admitted for any reason to one of 17 university or university-affiliated participating ICUs in France and Belgium (2010–2012). The primary outcome was vital status at hospital discharge. Results Of the 1011 patients enrolled initially, 226 (22.4%) had neurological failure. Presenting manifestations were dominated by drowsiness or stupor (65%), coma (32%), weakness (26%), and seizures (19%). Neuroimaging, lumbar puncture, and electroencephalography were performed in 113 (50%), 73 (32%), and 63 (28%) patients, respectively. A neurosurgical biopsy was done in 1 patient. Hospital mortality was 50%. By multivariate analysis, factors independently associated with higher hospital mortality were poor performance status (odds ratio [OR], 3.99; 95%CI, 1.82–9.39; P = 0.0009), non-Hodgkin’s lymphoma (OR, 2.60; 95%CI, 1.35–5.15; P = 0.005), shock (OR, 1.95; 95%CI, 1.04–3.72; P = 0.04), and respiratory failure (OR, 2.18; 95%CI, 1.14–4.25; P = 0.02); and factors independently associated with lower hospital mortality were GCS score on day 1 (OR, 0.88/point; 95%CI, 0.81–0.95; P = 0.0009) and autologous stem cell transplantation (OR, 0.25; 95%CI, 0.07–0.75; P = 0.02). Conclusions In ICU patients with hematological malignancies, neurological failure is common and often fatal. Independent predictors of higher hospital mortality were type of underlying hematological malignancy, poor performance status, hemodynamic and respiratory failures, and severity of consciousness impairment. Knowledge of these risk factors might help to optimize management strategies. PMID:28598990
Teras, Lauren R; Diver, W Ryan; Turner, Michelle C; Krewski, Daniel; Sahar, Liora; Ward, Elizabeth; Gapstur, Susan M
2016-07-01
Dosimetric models show that radon, an established cause of lung cancer, delivers a non-negligible dose of alpha radiation to the bone marrow, as well as to lymphocytes in the tracheobronchial epithelium, and therefore could be related to risk of hematologic cancers. Studies of radon and hematologic cancer risk, however, have produced inconsistent results. To date there is no published prospective, population-based study of residential radon exposure and hematologic malignancy incidence. We used data from the American Cancer Society Cancer Prevention Study-II Nutrition Cohort established in 1992, to examine the association between county-level residential radon exposure and risk of hematologic cancer. The analytic cohort included 140,652 participants (66,572 men, 74,080 women) among which 3019 incident hematologic cancer cases (1711 men, 1308 women) were identified during 19 years of follow-up. Cox proportional hazard regression was used to calculate multivariable-adjusted hazard ratios (HRs) and corresponding 95% confidence intervals (CIs) for radon exposure and hematologic cancer risk. Women living in counties with the highest mean radon concentrations (>148Bq/m(3)) had a statistically significant higher risk of hematologic cancer compared to those living in counties with the lowest (<74Bq/m(3)) radon levels (HR=1.63, 95% CI:1.23-2.18), and there was evidence of a dose-response relationship (HRcontinuous=1.38, 95% CI:1.15-1.65 per 100Bq/m(3); p-trend=0.001). There was no association between county-level radon and hematologic cancer risk among men. The findings of this large, prospective study suggest residential radon may be a risk factor for lymphoid malignancies among women. Further study is needed to confirm these findings. Copyright © 2016 Elsevier Inc. All rights reserved.
Karlson, Cynthia W; Haynes, Stacey; Faith, Melissa A; Elkin, Thomas D; Smith, Maria L; Megason, Gail
2015-03-01
A growing body of literature has begun to underscore the importance of integrating family-based comprehensive psychological screening into standard medical care for children with oncology and hematology conditions. There are no known family-based measures designed to screen for clinically significant emotional and behavioral concerns in pediatric oncology and hematology patients. The aim of this study was to develop and evaluate the Family Symptom Inventory (FSI), a brief screener of patient and family member psychological symptoms. The FSI also screens for common comorbid physical symptoms (pain and sleep disturbance) and is designed for use at any point during treatment and follow-up. A total of 488 caregivers completed the FSI during regular hematology/oncology visits for 193 cancer, 219 sickle cell disease, and 76 hematology pediatric patients. Exploratory factor analysis, confirmatory factor analysis, and tests of reliability and preliminary validity were conducted. Exploratory factor analysis suggested a 34-item, 4-factor solution, which was confirmed in an independent sample using confirmatory factor analysis (factor loadings=0.49 to 0.88). The FSI demonstrated good internal reliability (α's=0.86 to 0.92) and good preliminary validity. Regular psychosocial screening throughout the course of treatment and follow-up may lead to improved quality of care for children with oncology and hematology conditions.
[Evaluation of the performances of the UF-1000i(®) automated urine analyzer].
Fabbro, Christelle; Darolles, Jacques; Rault, Jean-Philippe
2011-01-01
The purpose of this study was the evaluation of the UF 1000i(®) automated urine analyzer (bioMérieux(©)).The coefficients of variation (CV) for the repeatability of the red blood cell (RBC), white blood cell (WBC) and bacteria counts were overall concordant with those announced by the supplier. However, for low concentrations, the CV for the repeatability for concentrations of 10(3) RBC/mL, 10(3) WBC/mL and 5×10(3) UA/mL were respectively of 26, 18 and 36% and thus higher than the CV (10%) reported for each of the three parameters by the supplier. Reproducibility results agreed with those given by the supplier (10%). The linearity range was different from that reported by the supplier and was shifted by a factor 10 for WBC and bacteria high concentrations. Cross contamination between samples was prevented by using the washing program recommended by the supplier which however led to a lower analysis frequency (80 samples per hour). Detection limits were of 5,7×10(1) RBC/mL, 5,7×10(1) WBC/mL and 1,6×10(4) UA/mL respectively for the RBC, WBC and bacteria. Quantification limits found in this study were of 1,3×10(3) RBC/mL, 1,7×10(3) WBC/mL, 5,1×10(3) UA/mL. An overestimation of the RBC count was observed within the range of 5×10(3) to 2×10(4) RBC/mL. Beyond this concentration range, the concordance is good. The correlation is poor within this range and good for higher concentrations. For WBC, concordance and correlation were satisfactory over the whole range tested.
Carmo, Andreia Moreira Dos Santos; Suzuki, Rodrigo Buzinaro; Cabral, Aline Diniz; Costa, Renata Torres da; Massari, Gabriela Pena; Riquena, Michele Marcondes; Fracasso, Helio Augusto Alves; Eterovic, Andre; Marcili, Arlei; Sperança, Márcia Aparecida
2017-05-01
Dengue virus, represented by four distinct, genetically diverse serotypes, is the etiologic agent of asymptomatic to severe hemorrhagic diseases. The spatiotemporal dynamics of dengue serotypes and its association to specific diseases vary among the different regions worldwide. By 2007, and in São Paulo State, Brazil, dengue-case concentration in urban centers had changed to increased incidence in small- and medium-sized towns, the case of Marília. The aim of this article was to distinguish dengue serotypes circulating during the 2007 Marília outbreak and define their association to demographic and hematological patient profiles, as well as the phylogenetic relationships among the different viruses. PCR amplicons corresponding to the junction of capsid and dengue pre-membrane encoding genes, obtained from dengue serologically positive patients, were sequenced. Hematological and demographic data of patients with different Dengue serotypes were evaluated by univariate and bivariate statistics. Dengue PCR sequences were used in phylogenetic relationships analyzed for maximum parsimony. Molecular typing confirmed co-circulation of the dengue serotypes 1 (DENV1) and 3 (DENV3), which presented divergent correlation patterns with regard to hematological descriptors. The increase in atypical lymphocytes, a likely indication of virus load, could be significantly associated to a decrease in leukocyte counts in the DENV3 group and platelet in the DENV1. Phylogenetic reconstitution revealed the introduction of DENV1 from northern Brazil and local divergence of DENV3 by either microevolution or viral introduction from other geographical regions or both. Dengue dynamics showed regional molecular-epidemiologic specificity, which has important implications for introduction of vaccines, disease management, and transmission control. Copyright © 2017 Elsevier B.V. All rights reserved.
Al Balushi, K A; Balkhair, A; Ali, B H; Al Rawas, N
2013-06-01
The aim of this study was to describe the antimicrobial prescription patterns of patients with hematological malignancies who developed febrile neutropenia (FN) at Sultan Qaboos University Hospital (SQUH) in Oman. This was a retrospective observational study covering a period of 3 years (January 2007-February 2010). FN episodes were studied in patients with hematological malignancies in three different wards at SQUH. A total of 176 FN episodes were analyzed. Overall, 64% of the 107 patients studied experienced at least 2 episodes during the analysis period. Approximately, 69% of the febrile neutropenia episodes had severe neutropenia. The duration of neutropenia was less than 1 week in the majority of the episodes (57%). The mean duration of treatment was approximately 7 days, with no significant difference between specialties or different types of malignancies. Only 34 (19%) episodes had positive cultures, and most of these were from blood samples (30 episodes, 88%). The majority of isolates were gram-negative organisms (63%). The initial empirical treatment included monotherapy (37%), dual therapy (60%) and triple therapy (3%). This study demonstrates that there is a large variation in the antimicrobial treatment of FN episodes in patients with hematological malignancies at SQUH. All chosen drugs were within international guideline recommendations. Copyright © 2013 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.
Aleksandrova, E N; Kovacheva, N P
2010-01-01
The application of hematological analysis techniques to detecting the physiological status of the economically valued decapods during their culturing, and in monitoring of the condition of their natural populations, is restrained by the incomplete knowledge of these invertebrates circulatory system and its properties. Scarce data on the use of hematological indicators for determining the physiological status of decapods may be found sporadically in published sources; there is shortage of basic standards needed for interpretation of the analytical results. In this regard the paper considers some data on the major properties of hemolymph and its cellular elements; on methods of their examination; and on the results of application of hematological characteristics to assessing the physiological condition of various species of decapods. The hematological indicators suitable for the analysis of live decapods include: time of coagulation and buffer characteristic of hemolymph; concentration of total proteins, copper, calcium, glucose and lactates in it; total number of hemocytes with the consideration of granulocytes share.
Planning for the future workforce in hematology research
Abkowitz, Janis L.; Coller, Barry S.; DiMichele, Donna M.
2015-01-01
The medical research and training enterprise in the United States is complex in both its scope and implementation. Accordingly, adaptations to the associated workforce needs present particular challenges. This is particularly true for maintaining or expanding national needs for physician-scientists where training resource requirements and competitive transitional milestones are substantial. For the individual, these phenomena can produce financial burden, prolong the career trajectory, and significantly influence career pathways. Hence, when national data suggest that future medical research needs in a scientific area may be met in a less than optimal manner, strategies to expand research and training capacity must follow. This article defines such an exigency for research and training in nonneoplastic hematology and presents potential strategies for addressing these critical workforce needs. The considerations presented herein reflect a summary of the discussions presented at 2 workshops cosponsored by the National Heart, Lung, and Blood Institute and the American Society of Hematology. PMID:25758827
Planning for the future workforce in hematology research.
Hoots, W Keith; Abkowitz, Janis L; Coller, Barry S; DiMichele, Donna M
2015-04-30
The medical research and training enterprise in the United States is complex in both its scope and implementation. Accordingly, adaptations to the associated workforce needs present particular challenges. This is particularly true for maintaining or expanding national needs for physician-scientists where training resource requirements and competitive transitional milestones are substantial. For the individual, these phenomena can produce financial burden, prolong the career trajectory, and significantly influence career pathways. Hence, when national data suggest that future medical research needs in a scientific area may be met in a less than optimal manner, strategies to expand research and training capacity must follow. This article defines such an exigency for research and training in nonneoplastic hematology and presents potential strategies for addressing these critical workforce needs. The considerations presented herein reflect a summary of the discussions presented at 2 workshops cosponsored by the National Heart, Lung, and Blood Institute and the American Society of Hematology.
Effects of whirling disease on selected hematological parameters in rainbow trout
Densmore, Christine L.; Blazer, V.S.; Waldrop, T.B.; Pooler, P.S.
2001-01-01
Hematological responses to whirling disease in rainbow trout (Oncorhynchus mykiss) were investigated. Two-mo-old fingerling rainbow trout were exposed to cultured triactinomyxon spores of Myxobolus cerebralis at 9,000 spores/fish in December, 1997. Twenty-four wks post-exposure, fish were taken from infected and uninfected groups for peripheral blood and cranial tissue sampling. Histological observations on cranial tissues confirmed M. cerebralis infection in all exposed fish. Differences in hematological parameters between the two groups included significantly lower total leukocyte and small lymphocyte counts for the infected fish. No effects on hematocrit, plasma protein concentration, or other differential leukocyte counts were noted.
A wide-band high-resolution spectrum analyzer
NASA Technical Reports Server (NTRS)
Quirk, Maureen P.; Garyantes, Michael F.; Wilck, Helmut C.; Grimm, Michael J.
1988-01-01
A two-million-channel, 40 MHz bandwidth, digital spectrum analyzer under development at the Jet Propulsion Laboratory is described. The analyzer system will serve as a prototype processor for the sky survey portion of NASA's Search for Extraterrestrial Intelligence program and for other applications in the Deep Space Network. The analyzer digitizes an analog input, performs a 2 (sup 21) point Discrete Fourier Transform, accumulates the output power, normalizes the output to remove frequency-dependent gain, and automates simple detection algorithms. Due to its built-in frequency-domain processing functions and configuration flexibility, the analyzer is a very powerful tool for real-time signal analysis.
A wide-band high-resolution spectrum analyzer.
Quirk, M P; Garyantes, M F; Wilck, H C; Grimm, M J
1988-12-01
This paper describes a two-million-channel 40-MHz-bandwidth, digital spectrum analyzer under development at the Jet Propulsion Laboratory. The analyzer system will serve as a prototype processor for the sky survey portion of NASA's Search for Extraterrestrial Intelligence program and for other applications in the Deep Space Network. The analyzer digitizes an analog input, performs a 2(21)-point, Discrete Fourier Transform, accumulates the output power, normalizes the output to remove frequency-dependent gain, and automates simple signal detection algorithms. Due to its built-in frequency-domain processing functions and configuration flexibility, the analyzer is a very powerful tool for real-time signal analysis and detection.
Proceedings from the 1st Insights in Hematology Symposium, Cluj-Napoca, Romania March 11-12, 2016.
Bojan, Anca; Berindan-Neagoe, Ioana; Ciurea, S; Dima, Delia; Fuji, Shigeo; Ghiaur, G; Grewal, Ravnit; Mccormack, Emmet; Tanase, Alina; Trifa, A; Tomuleasa, Ciprian
2016-09-01
In the March 2016 issue of the Lancet Haematology, the editorial office published a paper stating the roadmap for European research in hematology, based on the European Hematology Association (EHA) consensus document that outlines the directions in hematology for the following years across the continent. The meeting entitled "Insights in hematology" is organized a support for the initiative of a roadmap for European hematologists regarding research, may it be basic research or clinical research, but this consensus should not be focused mainly on European institutions, but rather form the backbone of global research between Europe and the United States, Japan or any other country. This will allow Europeans to learn as well as to share their experience with the rest of the scientific and medical community. And the Cluj-Napoca meeting should be followed by other such meetings all across the EU.
Blood at 70: its roots in the history of hematology and its birth
2015-01-01
This year we celebrate Blood's 70th year of publication. Created from the partnership of the book publisher Henry M. Stratton and the prominent hematologist Dr William Dameshek of Tufts School of Medicine, Blood has published many papers describing major advances in the science and clinical practice of hematology. Blood's founding antedated that of the American Society of Hematology (ASH) by more than 11 years and Stratton and Dameshek helped galvanize support for the creation of ASH. In this review, I place the birth of Blood in the context of the history of hematology before 1946, emphasizing the American experience from which it emerged, and focusing on research conducted during World War II. I also provide a few milestones along Blood's 70 years of publication, including: the growth in Blood's publications, the evolution of its appearance, the countries of submission of Blood papers, current subscriptions to Blood, and the evolution of topics reported in Blood's papers. The latter provides a snapshot of the evolution of hematology as a scientific and clinical discipline and the introduction of new technology to study blood and bone marrow. Detailed descriptions of the landmark discoveries reported in Blood will appear in later papers celebrating Blood's birthday authored by past Editors-in-Chief. PMID:26631112
Alxneit, Ivo
2018-03-30
A python module (HRTEMFringeAnalyzer) is reported to evaluate the local crystallinity of samples from high-resolution transmission electron microscopy images in a mostly automated fashion. The user only selects the size of a square analyser window and a step size which translates the window in the micrograph. Together they define the resolution of the results obtained. Regions where fringe patterns are visible are identified and their lattice spacing d and direction ϕ as well as the corresponding mean errors σ determined. 1/σd is proportional to the coherence length of the structure, whereas σφ is a measure of how well the direction of the fringes is defined. Maps of these four indicators are computed. The performance of the program is demonstrated on two very different samples: ill-crystalline carbon deposits on a coked Ni/LFNO (reduced LaFe 0.8 Ni 0.2 O3±δ) catalyst and well-crystallized nanoparticles of zinc doped ceria. In the latter case, the automatic segmentation of large aggregates into individual crystalline domains is achieved by ϕ maps. © 2018 The Authors Journal of Microscopy © 2018 Royal Microscopical Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Teras, Lauren R., E-mail: lauren.teras@cancer.org; Diver, W. Ryan; Turner, Michelle C.
Dosimetric models show that radon, an established cause of lung cancer, delivers a non-negligible dose of alpha radiation to the bone marrow, as well as to lymphocytes in the tracheobronchial epithelium, and therefore could be related to risk of hematologic cancers. Studies of radon and hematologic cancer risk, however, have produced inconsistent results. To date there is no published prospective, population-based study of residential radon exposure and hematologic malignancy incidence. We used data from the American Cancer Society Cancer Prevention Study-II Nutrition Cohort established in 1992, to examine the association between county-level residential radon exposure and risk of hematologic cancer.more » The analytic cohort included 140,652 participants (66,572 men, 74,080 women) among which 3019 incident hematologic cancer cases (1711 men, 1308 women) were identified during 19 years of follow-up. Cox proportional hazard regression was used to calculate multivariable-adjusted hazard ratios (HRs) and corresponding 95% confidence intervals (CIs) for radon exposure and hematologic cancer risk. Women living in counties with the highest mean radon concentrations (>148 Bq/m{sup 3}) had a statistically significant higher risk of hematologic cancer compared to those living in counties with the lowest (<74 Bq/m{sup 3}) radon levels (HR=1.63, 95% CI:1.23–2.18), and there was evidence of a dose-response relationship (HR{sub continuous}=1.38, 95% CI:1.15–1.65 per 100 Bq/m{sup 3}; p-trend=0.001). There was no association between county-level radon and hematologic cancer risk among men. The findings of this large, prospective study suggest residential radon may be a risk factor for lymphoid malignancies among women. Further study is needed to confirm these findings. - Highlights: • This is the first prospective, general population study of residential radon and risk of hematologic cancer. • Findings from this study suggest that residential radon exposure may be a
Silva, Cínthia R B; Putarov, Thaila C; Fruhvald, Erika; Destro, Flavia C; Marques Filho, Wolff C; Thomazini, Camila M; Barbosa, Tatiana S; Orsi, Ricardo O; Siqueira, Edson R
2014-07-01
The present study aimed to evaluate the effect of propolis use on hematological and serum biochemical parameters in Blue-fronted Amazons (Amazona aestiva). For this, 12 adult birds were distributed randomly into individual cages, divided into treatments with different propolis levels (A = 0.0%; B = 0.5%; and C = 1.0%), in 3 distinct phases (I, II, and III), with 15-d duration for phases I and III and 30 d for phase II, totaling 60 d. In phases I and III, all birds received treatment A ration, and in phase II received A, B, or C (4 birds per treatment). At the end of each phase, blood was collected for biochemical and hematological evaluations. The variables were analyzed by ANOVA (P < 0.05). Results suggest that 0.5% propolis reduced lactate dehydrogenase levels, whereas treatment B augmented hemoglobin concentrations and eosinophil count. It is concluded that 0.5% propolis improves levels of lactate dehydrogenase, hemoglobin, and eosinophils. © 2014 Poultry Science Association Inc.
Signal amplification of FISH for automated detection using image cytometry.
Truong, K; Boenders, J; Maciorowski, Z; Vielh, P; Dutrillaux, B; Malfoy, B; Bourgeois, C A
1997-05-01
The purpose of this study was to improve the detection of FISH signals, in order that spot counting by a fully automated image cytometer be comparable to that obtained visually under the microscope. Two systems of spot scoring, visual and automated counting, were investigated in parallel on stimulated human lymphocytes with FISH using a biotinylated centromeric probe for chromosome 3. Signal characteristics were first analyzed on images recorded with a coupled charge device (CCD) camera. Number of spots per nucleus were scored visually on these recorded images versus automatically with a DISCOVERY image analyzer. Several fluochromes, amplification and pretreatments were tested. Our results for both visual and automated scoring show that the tyramide amplification system (TSA) gives the best amplification of signal if pepsin treatment is applied prior to FISH. Accuracy of the automated scoring, however, remained low (58% of nuclei containing two spots) compared to the visual scoring because of the high intranuclear variation between FISH spots.
Newman, S.H.; Piatt, John F.; White, J.
1997-01-01
Blood was analyzed from 151 pelagic marine birds to establish reference ranges for hematological and plasma biochemical parameters from healthy, wild populations of Pacific seabirds. Of the 13 species examined, 9 were from the Family Alcidae (N = 122 individuals) and the remainder (N = 29) from the Families Phalacrocoracidae, Laridae, and Procellariidae. Three of 8 hematological parameters (total white blood cell count, lymphocyte count and eosinophil count) differed significantly among species, as did 9 of 13 plasma biochemical parameters (alkaline phosphatase, aspartate aminotransferase, creatine kinase, cholesterol, glucose, lactate dehydrogenase, total bilirubin, total protein and field total protein). There were no differences among species for packed cell volume, buffy coat, cell counts of heterophils, monocytes and basophils, or for concentrations of alanine aminotransferase, triglycerides, uric acid and calcium. Plasma calcium concentration, triglyceride levels and field total protein varied significantly between sexes, with females having higher mean concentrations of all 3 parameters. However, no significant relationships between measures of breeding condition (brood patch size, subcutaneous and mesenteric fat deposits, or ovarian follicle size and ovary weight) and calcium or alkaline phosphatase concentrations in female birds could be identified. Alanine aminotransferase and uric acid were the only analytes which did not differ significantly between species or sexes.
Shimizu, Sanae; Kojima, Yukari; Saito, Kyoko; Wada, Hisako; Yamamoto, Masahiro; Morinaga, Koji; Kawai, Yasukazu; Haba, Toshihiro
2014-11-01
The clinical path for the treatment of acute myeloid leukemia (AML) patients has been in practice in our hospital since 2003. In the clinical path, laboratory technologists take on the role of explaining the microscopic findings in bone marrow and peripheral blood samples to patients (with or without their families) using the view-sharing microscope in our laboratory. From July 2003 to October 2014, 56 patients were enrolled in the AML clinical path and given an explanation of their bone marrow and peripheral blood samples. The patients' median age was 62, and the median time spent for explanation was 40 minutes. We conducted a questionnaire feedback survey involving those who enrolled, and the results showed significant improvement in the recognition of the disease pathophysiology, treatment efficacy, and the importance of precautions against infectious diseases. Based on the feedback, we have made marked efforts to provide patients with an improved environment during the explanatory session. This includes installing a special display for the patients, drawing a schematic illustration that shows how the blood cells differentiate, and putting them into operation in a hematology ward to promote patient privacy and precautions against infectious diseases. Hematological laboratory technologists have played an important role in patient care in our hospital. To perform their role as effectively as possible, hematological laboratory technologists participate in the conferences of the Department of Hematology and Oncology regularly, in which medical staff members can discuss the conditions and clinical courses of patients. We aim to contribute to patient satisfaction by sophisticating specialized knowledge as hematological laboratory technologists and cooperate with other medical staff members.
LaGrange, Seth M; Kimble, Steven J A; MacGowan, Brian J; Williams, Rod N
2014-10-01
Hematology, biochemical analyses, and body condition indices are useful tools for describing animal health, especially when making management decisions for species of conservation concern. We report hematologic, biochemical, and body condition index data for 13 free-ranging timber rattlesnakes (Crotalus horridus) sampled repeatedly over an active season in Indiana, USA.
Schmidt-Hieber, M.; Silling, G.; Schalk, E.; Heinz, W.; Panse, J.; Penack, O.; Christopeit, M.; Buchheidt, D.; Meyding-Lamadé, U.; Hähnel, S.; Wolf, H. H.; Ruhnke, M.; Schwartz, S.; Maschmeyer, G.
2016-01-01
Infections of the central nervous system (CNS) are infrequently diagnosed in immunocompetent patients, but they do occur in a significant proportion of patients with hematological disorders. In particular, patients undergoing allogeneic hematopoietic stem-cell transplantation carry a high risk for CNS infections of up to 15%. Fungi and Toxoplasma gondii are the predominant causative agents. The diagnosis of CNS infections is based on neuroimaging, cerebrospinal fluid examination and biopsy of suspicious lesions in selected patients. However, identification of CNS infections in immunocompromised patients could represent a major challenge since metabolic disturbances, side-effects of antineoplastic or immunosuppressive drugs and CNS involvement of the underlying hematological disorder may mimic symptoms of a CNS infection. The prognosis of CNS infections is generally poor in these patients, albeit the introduction of novel substances (e.g. voriconazole) has improved the outcome in distinct patient subgroups. This guideline has been developed by the Infectious Diseases Working Party (AGIHO) of the German Society of Hematology and Medical Oncology (DGHO) with the contribution of a panel of 14 experts certified in internal medicine, hematology/oncology, infectious diseases, intensive care, neurology and neuroradiology. Grades of recommendation and levels of evidence were categorized by using novel criteria, as recently published by the European Society of Clinical Microbiology and Infectious Diseases. PMID:27052648
Katavolos, P; Staempfli, S; Sears, W; Gancz, A Y; Smith, D A; Bienzle, D
2007-12-01
Lead is a persistent contaminant in the environment, and waterfowl are susceptible to lead toxicity from ingestion of lead pellets and fishing weights. Lead affects numerous physiologic processes through inhibition of enzyme activity and protein function, but its effects on commonly assessed avian blood values are incompletely understood. Our aim was to evaluate hematologic and biochemical changes associated with blood lead concentrations in trumpeter swans and Canada geese. Data for CBCs, plasma biochemical profiles (total protein, albumin, glucose, cholesterol, total bilirubin, calcium, phosphorus, gamma-glutamyltransferase [GGT], aspartate aminotransferase, lactate dehydrogenase, glutamate dehydrogenase, creatine kinase, amylase, and lipase), and whole blood lead concentrations were retrospectively analyzed for 69 trumpeter swans and 52 Canada geese. Laboratory data obtained prospectively from an additional 20 trumpeter swans also were included. RBC morphology was semiquantitated in blood smears from 70 of the birds. Data were analyzed initially by ANOVA and covariance. A statistical model then was constructed to determine the relationship between each parameter and lead concentration. In both avian species, PCV, hemoglobin concentration, and MCHC decreased significantly (P < .05) with increasing blood lead concentration. Uric acid concentration and GGT activity were increased in trumpeter swans and phosphorus concentration was decreased in Canada geese in association with high blood lead concentration (P < .05). Lead toxicosis induced significant changes in the values of commonly measured hematologic parameters in waterfowl. These changes may be useful indicators of severe lead intoxication during routine laboratory assessment. Changes in clinical chemistry values, although statistically significant, were too inconsistent to serve as indicators of lead toxicosis.
Automated SEM-EDS GSR Analysis for Turkish Ammunitions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cakir, Ismail; Uner, H. Bulent
2007-04-23
In this work, Automated Scanning Electron Microscopy with Energy Dispersive X-ray Spectrometry (SEM-EDS) was used to characterize 7.65 and 9mm cartridges Turkish ammunition. All samples were analyzed in a SEM Jeol JSM-5600LV equipped BSE detector and a Link ISIS 300 (EDS). A working distance of 20mm, an accelerating voltage of 20 keV and gunshot residue software was used in all analysis. Automated search resulted in a high number of particles analyzed containing gunshot residues (GSR) unique elements (PbBaSb). The obtained data about the definition of characteristic GSR particles was concordant with other studies on this topic.
NASA Technical Reports Server (NTRS)
Tijidjian, Raffi P.
2010-01-01
The TEAMS model analyzer is a supporting tool developed to work with models created with TEAMS (Testability, Engineering, and Maintenance System), which was developed by QSI. In an effort to reduce the time spent in the manual process that each TEAMS modeler must perform in the preparation of reporting for model reviews, a new tool has been developed as an aid to models developed in TEAMS. The software allows for the viewing, reporting, and checking of TEAMS models that are checked into the TEAMS model database. The software allows the user to selectively model in a hierarchical tree outline view that displays the components, failure modes, and ports. The reporting features allow the user to quickly gather statistics about the model, and generate an input/output report pertaining to all of the components. Rules can be automatically validated against the model, with a report generated containing resulting inconsistencies. In addition to reducing manual effort, this software also provides an automated process framework for the Verification and Validation (V&V) effort that will follow development of these models. The aid of such an automated tool would have a significant impact on the V&V process.
Five hematologic tests and treatments to question.
Hicks, Lisa K; Bering, Harriet; Carson, Kenneth R; Haynes, Adam E; Kleinerman, Judith; Kukreti, Vishal; Ma, Alice; Mueller, Brigitta U; O'Brien, Sarah H; Panepinto, Julie A; Pasquini, Marcelo C; Rajasekhar, Anita; Sarode, Ravi; Wood, William A
2014-12-05
Choosing Wisely® is a medical stewardship initiative led by the American Board of Internal Medicine Foundation in collaboration with professional medical societies in the United States. The American Society of Hematology (ASH) released its first Choosing Wisely® list in 2013. Using the same evidence-based methodology as in 2013, ASH has identified 5 additional tests and treatments that should be questioned by clinicians and patients under specific, indicated circumstances. The ASH 2014 Choosing Wisely® recommendations include: (1) do not anticoagulate for more than 3 months in patients experiencing a first venous thromboembolic event in the setting of major, transient risk factors for venous thromboembolism; (2) do not routinely transfuse for chronic anemia or uncomplicated pain crises in patients with sickle cell disease; (3) do not perform baseline or surveillance computed tomography scans in patients with asymptomatic, early-stage chronic lymphocytic leukemia; (4) do not test or treat for heparin-induced thrombocytopenia if the clinical pretest probability of heparin-induced thrombocytopenia is low; and (5) do not treat patients with immune thrombocytopenia unless they are bleeding or have very low platelet counts. © 2014 by The American Society of Hematology. All rights reserved.
Five hematologic tests and treatments to question.
Hicks, Lisa K; Bering, Harriet; Carson, Kenneth R; Haynes, Adam E; Kleinerman, Judith; Kukreti, Vishal; Ma, Alice; Mueller, Brigitta U; O'Brien, Sarah H; Panepinto, Julie A; Pasquini, Marcelo C; Rajasekhar, Anita; Sarode, Ravi; Wood, William A
2014-12-04
Choosing Wisely(®) is a medical stewardship initiative led by the American Board of Internal Medicine Foundation in collaboration with professional medical societies in the United States. The American Society of Hematology (ASH) released its first Choosing Wisely(®) list in 2013. Using the same evidence-based methodology as in 2013, ASH has identified 5 additional tests and treatments that should be questioned by clinicians and patients under specific, indicated circumstances. The ASH 2014 Choosing Wisely(®) recommendations include: (1) do not anticoagulate for more than 3 months in patients experiencing a first venous thromboembolic event in the setting of major, transient risk factors for venous thromboembolism; (2) do not routinely transfuse for chronic anemia or uncomplicated pain crises in patients with sickle cell disease; (3) do not perform baseline or surveillance computed tomography scans in patients with asymptomatic, early-stage chronic lymphocytic leukemia; (4) do not test or treat for heparin-induced thrombocytopenia if the clinical pretest probability of heparin-induced thrombocytopenia is low; and (5) do not treat patients with immune thrombocytopenia unless they are bleeding or have very low platelet counts. © 2014 by The American Society of Hematology. All rights reserved.
Silibinin: an old drug for hematological disorders.
Zou, Hai; Zhu, Xing-Xing; Zhang, Guo-Bing; Ma, Yuan; Wu, Yi; Huang, Dong-Sheng
2017-10-24
Silibinin (silybin), a non-toxic natural polyphenolic flavonoid, is the principal and the most biologically active component of silymarin. It is efficient in the treatment of acute and chronic liver disorders caused by toxins, drug, alcohol, hepatitis, and gall bladder disorders. Further, in our previous studies, we explored the anti-cancer efficacy in common cancers, such as lung, prostatic, colon, breast, bladder, as well as, hepatocellular carcinoma. Interestingly, silibinin is still not solely limited to the treatment of these diseases. Recent research endeavors suggest that silibinin may function diversely and serve as a novel therapy for hematological disorders. It discovered several interesting viewpoints in the widely studied mechanisms of silibinin in the hematological disorders. In this report, we review the up-to-date findings of more potency roles of silibinin in β-thalassemia (β-TM), acute myeloid leukemia (AML), anaplastic large cell lymphoma (ALCL) and multiple myelomas (MM) therapy and attempt to clarify the mechanisms underlying its effects. There are two viewpoints: First, The functional mechanisms of silibinin in AML cells via regulating cell differentiation to exert anti-cancer effect; Second, combination treatment strategy may be a good choice.
Silibinin: an old drug for hematological disorders
Zou, Hai; Zhu, Xing-Xing; Zhang, Guo-Bing; Ma, Yuan; Wu, Yi; Huang, Dong-Sheng
2017-01-01
Introduction Silibinin (silybin), a non-toxic natural polyphenolic flavonoid, is the principal and the most biologically active component of silymarin. It is efficient in the treatment of acute and chronic liver disorders caused by toxins, drug, alcohol, hepatitis, and gall bladder disorders. Further, in our previous studies, we explored the anti-cancer efficacy in common cancers, such as lung, prostatic, colon, breast, bladder, as well as, hepatocellular carcinoma. Interestingly, silibinin is still not solely limited to the treatment of these diseases. Recent research endeavors suggest that silibinin may function diversely and serve as a novel therapy for hematological disorders. Areas covered It discovered several interesting viewpoints in the widely studied mechanisms of silibinin in the hematological disorders. Expert commentary In this report, we review the up-to-date findings of more potency roles of silibinin in β-thalassemia (β-TM), acute myeloid leukemia (AML), anaplastic large cell lymphoma (ALCL) and multiple myelomas (MM) therapy and attempt to clarify the mechanisms underlying its effects. There are two viewpoints: First, The functional mechanisms of silibinin in AML cells via regulating cell differentiation to exert anti-cancer effect; Second, combination treatment strategy may be a good choice. PMID:29179521
Automated image-based phenotypic analysis in zebrafish embryos
Vogt, Andreas; Cholewinski, Andrzej; Shen, Xiaoqiang; Nelson, Scott; Lazo, John S.; Tsang, Michael; Hukriede, Neil A.
2009-01-01
Presently, the zebrafish is the only vertebrate model compatible with contemporary paradigms of drug discovery. Zebrafish embryos are amenable to automation necessary for high-throughput chemical screens, and optical transparency makes them potentially suited for image-based screening. However, the lack of tools for automated analysis of complex images presents an obstacle to utilizing the zebrafish as a high-throughput screening model. We have developed an automated system for imaging and analyzing zebrafish embryos in multi-well plates regardless of embryo orientation and without user intervention. Images of fluorescent embryos were acquired on a high-content reader and analyzed using an artificial intelligence-based image analysis method termed Cognition Network Technology (CNT). CNT reliably detected transgenic fluorescent embryos (Tg(fli1:EGFP)y1) arrayed in 96-well plates and quantified intersegmental blood vessel development in embryos treated with small molecule inhibitors of anigiogenesis. The results demonstrate it is feasible to adapt image-based high-content screening methodology to measure complex whole organism phenotypes. PMID:19235725
Management of acute perianal sepsis in neutropenic patients with hematological malignancy.
Baker, B; Al-Salman, M; Daoud, F
2014-04-01
In neutropenic patients with acute perianal sepsis in the setting of hematological malignancy, the classical clinical features of abscess formation are lacking. Additionally, the role of surgical intervention is not well established. In this review, we discuss the challenges and controversy regarding diagnosis and optimal management when clear surgical guidelines are absent. In the literature, there is great diversity in the surgical approach to these patients, which leads to a high percentage of diagnostic errors, risks of complications, and unnecessary interventions. We review the literature and assess whether surgical intervention produces better outcomes than a non-surgical approach. Studies published on perianal sepsis in neutropenic cancer patients were identified by searching PubMed using the following key words: "perianal sepsis/abscesses, anorectal sepsis/abscess, neutropenia, hematological malignancy, cancer". No randomized or prospective studies on the management of acute perianal sepsis in hematological malignancies were found. The largest retrospective study and most comprehensive clinical data demonstrated that 42% of patients were treated successfully without surgical intervention and without morbidity or mortality related to treatment chosen. Small retrospective studies advocated surgical intervention, while the majority of successes were in a non-operative treatment. It is difficult to formulate a conclusion given the small retrospective series on management of neutropenic patients with hematological malignancies. While there is no evidence mandating a routine surgical approach in this category of patients, non-surgical management including careful follow-up to determine whether the patient's condition is deteriorating or treatment has failed is an acceptable approach in selected patients without pathognomonic features of abscess. Comprehensive and well-designed prospective studies are needed to firmly establish the guidelines of treatment
Eghrari, Allen O; Mumtaz, Aisha A; Garrett, Brian; Rezaei, Mahsa; Akhavan, Mina S; Riazuddin, S Amer; Gottsch, John D
2017-01-01
Retroillumination photography analysis is an objective tool for the assessment of the number and distribution of guttae in eyes affected with Fuchs corneal dystrophy (FCD). Current protocols include manual processing of images; here, we assess validity and interrater reliability of automated analysis across various levels of FCD severity. Retroillumination photographs of 97 FCD-affected corneas were acquired, and total counts of guttae were previously summated manually. For each cornea, a single image was loaded into ImageJ software. We reduced color variability and subtracted background noise. Reflection of light from each gutta was identified as a local area of maximum intensity and counted automatically. Noise tolerance level was titrated for each cornea by examining a small region of each image with automated overlay to ensure appropriate coverage of individual guttae. We tested interrater reliability of automated counts of guttae across a spectrum of clinical and educational experience. A set of 97 retroillumination photographs was analyzed. Clinical severity as measured by a modified Krachmer scale ranged from a severity level of 1 to 5 in the set of analyzed corneas. Automated counts by an ophthalmologist correlated strongly with Krachmer grading (R = 0.79) and manual counts (R = 0.88). Intraclass correlation coefficients demonstrated strong correlation at 0.924 (95% CI, 0.870-0.958) among cases analyzed by 3 students, and 0.869 (95% CI, 0.797-0.918) among cases for which images were analyzed by an ophthalmologist and 2 students. Automated retroillumination photography analysis allows for grading of FCD severity with high resolution across a spectrum of disease severity.
Weintraub, Lauren; Figueiredo, Lisa; Roth, Michael; Levy, Adam
Communication skills are a competency highlighted by the Accreditation Council on Graduate Medical Education; yet, little is known about the frequency with which trainees receive formal training or what programs are willing to invest. We sought to answer this question and designed a program to address identified barriers. We surveyed pediatric fellowship program directors from all disciplines and, separately, pediatric hematology/oncology fellowship program directors to determine current use of formal communication skills training. At our institution, we piloted a standardized patient (SP)-based communication skills training program for pediatric hematology/oncology fellows. Twenty-seven pediatric hematology/oncology program directors and 44 pediatric program directors participated in the survey, of which 56% and 48%, respectively, reported having an established, formal communication skills training course. Multiple barriers to implementation of a communication skills course were identified, most notably time and cost. In the pilot program, 13 pediatric hematology/oncology fellows have participated, and 9 have completed all 3 years of training. Precourse assessment demonstrated fellows had limited comfort in various areas of communication. Following course completion, there was a significant increase in self-reported comfort and/or skill level in such areas of communication, including discussing a new diagnosis (p =.0004), telling a patient they are going to die (p =.005), discussing recurrent disease (p <.001), communicating a poor prognosis (p =.002), or responding to anger (p ≤.001). We have designed a concise communication skills training program, which addresses identified barriers and can feasibly be implemented in pediatric hematology/oncology fellowship.
Automated Management Of Documents
NASA Technical Reports Server (NTRS)
Boy, Guy
1995-01-01
Report presents main technical issues involved in computer-integrated documentation. Problems associated with automation of management and maintenance of documents analyzed from perspectives of artificial intelligence and human factors. Technologies that may prove useful in computer-integrated documentation reviewed: these include conventional approaches to indexing and retrieval of information, use of hypertext, and knowledge-based artificial-intelligence systems.
Students' Experiences with an Automated Essay Scorer
ERIC Educational Resources Information Center
Scharber, Cassandra; Dexter, Sara; Riedel, Eric
2008-01-01
The purpose of this research is to analyze preservice teachers' use of and reactions to an automated essay scorer used within an online, case-based learning environment called ETIPS. Data analyzed include post-assignment surveys, a user log of students' actions within the cases, instructor-assigned scores on final essays, and interviews with four…
Methods for automatically analyzing humpback song units.
Rickwood, Peter; Taylor, Andrew
2008-03-01
This paper presents mathematical techniques for automatically extracting and analyzing bioacoustic signals. Automatic techniques are described for isolation of target signals from background noise, extraction of features from target signals and unsupervised classification (clustering) of the target signals based on these features. The only user-provided inputs, other than raw sound, is an initial set of signal processing and control parameters. Of particular note is that the number of signal categories is determined automatically. The techniques, applied to hydrophone recordings of humpback whales (Megaptera novaeangliae), produce promising initial results, suggesting that they may be of use in automated analysis of not only humpbacks, but possibly also in other bioacoustic settings where automated analysis is desirable.
Examination of Automation-Induced Complacency and Individual Difference Variates
NASA Technical Reports Server (NTRS)
Prinzel, Lawrence J., III; DeVries, Holly; Freeman, Fred G.; Mikulka, Peter
2001-01-01
Automation-induced complacency has been documented as a cause or contributing factor in many airplane accidents throughout the last two decades. It is surmised that the condition results when a crew is working in highly reliable automated environments in which they serve as supervisory controllers monitoring system states for occasional automation failures. Although many reports have discussed the dangers of complacency, little empirical research has been produced to substantiate its harmful effects on performance as well as what factors produce complacency. There have been some suggestions, however, that individual characteristics could serve as possible predictors of performance in automated systems. The present study examined relationship between the individual differences of complacency potential, boredom proneness, and cognitive failure, automation-induced complacency. Workload and boredom scores were also collected and analyzed in relation to the three individual differences. The results of the study demonstrated that there are personality individual differences that are related to whether an individual will succumb to automation-induced complacency. Theoretical and practical implications are discussed.
Yahagi, Masashi; Tsuruta, Masashi; Hasegawa, Hirotoshi; Okabayashi, Koji; Kitagawa, Yuko
2017-04-01
Liver dysfunction that may affect drug metabolism is a major concern in patients treated with chemotherapy. Thus, assessment of the degree of liver dysfunction is crucial for predicting the adverse events of chemotherapy. The non-alcoholic fatty liver disease fibrosis score (NFS) is a non-invasive clinical scoring system constructed from routine clinical and laboratory variables. The aim of this study was to evaluate whether NFS was useful for predicting the adverse events of chemotherapy including irinotecan (CPT-11) for colorectal cancer. Between January, 2007 and May, 2013, a total of 87 patients with unresectable/recurrent colorectal cancer who received first-line chemotherapy including CPT-11 were reviewed. Demographic variables, including pretreatment NFS, were retrospectively collected from medical records. The primary outcome was the association between pretreatment NFS and adverse events, such as hematological and non-hematological toxicity, of chemotherapy including CPT-11. The median pretreatment NFS was 1.302 (range, 5.158-2.620). Pretreatment NFS was an independent risk factor for hematological toxicity in a multivariate analysis (coefficient=0.932, 95% CI: 0.083-1.781; P=0.031). Receiver operating characteristic curve analysis identified 0.347 as the optimal cut-off value associated with hematological toxicity. Using this cut-off, high NFS was found to be a significant risk factor for hematological toxicity (coefficient=2.019, 95% CI: 0.239-3.798, P=0.026), but not for non-hematological toxicity (P=0.546). Therefore, based on these results, NFS appears to be a significant predictor of hematological adverse events in chemotherapy including CPT-11 for colorectal cancer and it is a non-invasive, useful tool that may be used for determining regimens or doses of chemotherapy including CPT-11.
Abdulqadir, Ibrahim; Ahmed, Sagir Gumel; Kuliya, Aisha Gwarzo; Tukur, Jamilu; Yusuf, Aminu Abba; Musa, Abubakar Umar
2018-01-01
Human immunodeficiency virus (HIV) scourge continues to affect young women within the reproductive age group and pregnancy is a recognized indication for the use antiretroviral (ARV) drugs among HIV-positive women. The aim is to determine the combined effect of pregnancy, HIV and ARV drugs on the hematological parameters of the pregnant women. This was a comparative cross-sectional study conducted among 70 each of HIV-positive and negative pregnant women. Bio-demographic and clinical data were extracted from the client folder and 4 ml of blood sample was obtained from each participant. Full blood count was generated using Swelab automatic hematology analyzer while reticulocyte count and erythrocyte sedimentation rate (ESR) were conducted manually. Data analysis was performed using SPSS version software 16 while P < 0.05 was considered statistically significant. Pregnant women with HIV had statistically significant lower hematocrit and white blood cell (WBC) and higher ESR than pregnant women without HIV ( P < 0.000). There was no statistically significant difference between the two groups in terms of platelet and reticulocyte ( P > 0.05). However, among HIV positive pregnant women, those with CD4 count <350/μL had statistically significant lower WBC and lymphocyte count than those with CD4 count ≥350/μL ( P < 0.05), whereas, those on zidovudine (AZT)-containing treatment had statistically significant lower hematocrit and higher mean cell volume than those on non-AZT-containing treatment ( P < 0.05), but there was no statistically significant difference in any of the hematological parameters ( P > 0.050) between women on first- and second-line ARV regimens. There is a significant difference in terms of hematological parameters between HIV-positive and HIV-negative pregnant women in this environment.
Elvevåg, Brita; Foltz, Peter W.; Rosenstein, Mark; DeLisi, Lynn E.
2009-01-01
Communication disturbances are prevalent in schizophrenia, and since it is a heritable illness these are likely present - albeit in a muted form - in the relatives of patients. Given the time-consuming, and often subjective nature of discourse analysis, these deviances are frequently not assayed in large scale studies. Recent work in computational linguistics and statistical-based semantic analysis has shown the potential and power of automated analysis of communication. We present an automated and objective approach to modeling discourse that detects very subtle deviations between probands, their first-degree relatives and unrelated healthy controls. Although these findings should be regarded as preliminary due to the limitations of the data at our disposal, we present a brief analysis of the models that best differentiate these groups in order to illustrate the utility of the method for future explorations of how language components are differentially affected by familial and illness related issues. PMID:20383310
Altering user' acceptance of automation through prior automation exposure.
Bekier, Marek; Molesworth, Brett R C
2017-06-01
Air navigation service providers worldwide see increased use of automation as one solution to overcome the capacity constraints imbedded in the present air traffic management (ATM) system. However, increased use of automation within any system is dependent on user acceptance. The present research sought to determine if the point at which an individual is no longer willing to accept or cooperate with automation can be manipulated. Forty participants underwent training on a computer-based air traffic control programme, followed by two ATM exercises (order counterbalanced), one with and one without the aid of automation. Results revealed after exposure to a task with automation assistance, user acceptance of high(er) levels of automation ('tipping point') decreased; suggesting it is indeed possible to alter automation acceptance. Practitioner Summary: This paper investigates whether the point at which a user of automation rejects automation (i.e. 'tipping point') is constant or can be manipulated. The results revealed after exposure to a task with automation assistance, user acceptance of high(er) levels of automation decreased; suggesting it is possible to alter automation acceptance.
Laboratory systems integration: robotics and automation.
Felder, R A
1991-01-01
Robotic technology is going to have a profound impact on the clinical laboratory of the future. Faced with increased pressure to reduce health care spending yet increase services to patients, many laboratories are looking for alternatives to the inflexible or "fixed" automation found in many clinical analyzers. Robots are being examined by many clinical pathologists as an attractive technology which can adapt to the constant changes in laboratory testing. Already, laboratory designs are being altered to accommodate robotics and automated specimen processors. However, the use of robotics and computer intelligence in the clinical laboratory is still in its infancy. Successful examples of robotic automation exist in several laboratories. Investigators have used robots to automate endocrine testing, high performance liquid chromatography, and specimen transportation. Large commercial laboratories are investigating the use of specimen processors which combine the use of fixed automation and robotics. Robotics have also reduced the exposure of medical technologists to specimens infected with viral pathogens. The successful examples of clinical robotics applications were a result of the cooperation of clinical chemists, engineers, and medical technologists. At the University of Virginia we have designed and implemented a robotic critical care laboratory. Initial clinical experience suggests that robotic performance is reliable, however, staff acceptance and utilization requires continuing education. We are also developing a robotic cyclosporine which promises to greatly reduce the labor costs of this analysis. The future will bring lab wide automation that will fully integrate computer artificial intelligence and robotics. Specimens will be transported by mobile robots. Specimen processing, aliquotting, and scheduling will be automated.(ABSTRACT TRUNCATED AT 250 WORDS)
Hematology, plasma chemistry, and bacteriology of wild Tundra Swans (Cygnus columbianus) in Alaska.
Milani, Juliana F; Wilson, Heather; Ziccardi, Michael; LeFebvre, Rance; Scott, Cheryl
2012-01-01
Blood and cloacal swabs were collected from 100 (66 female, 34 male) wild Tundra Swans (Cygnus columbianus) molting in northwestern Alaska, USA, 25-28 July 2008, to establish hematologic and serum chemistry reference values and to isolate enteric Salmonella spp. and Escherichia coli O157:H7. Plasma biochemistry and hematology values did not vary significantly by sex or age. Tundra swans had high levels of creatine kinase, lactate dehydrogenase, amylase, and alkaline phosphatase compared with some other avian species (values were up to 7 times greater), possibly indicating capture myopathy. However, concentrations were much lower (up to 8 times lower) than in other waterfowl exposed to similar or more intensive capture methods. White blood cell count and hematocrit values were similar to other waterfowl species, and enteric Salmonella spp. and E. coli O157:H7 were not present among birds sampled. Our data provide the first biochemical, hematologic, and bacteriologic reference values for wild Tundra Swans.
Hematology and plasma chemistry reference intervals for cultured tilapia (Oreochromis hybrid).
Hrubec, Terry C.; Cardinale, Jenifer L.; Smith, Stephen A.
2000-01-01
Tilapia are a commonly aquacultured fish yet little is known about their normal physiology and response to disease. In this study we determined the results of complete hematologic (n=40) and plasma biochemical profiles (n=63) in production tilapia (Oreochromis hybrids). The fish were raised in recirculating systems with a high stocking density (120 g/L), and were in the middle of a 15-month production cycle. Blood was analyzed using standard techniques, and reference intervals were determined using nonparametric methods. Non-production tilapia (n=15) from low-density tanks (4 g/L) also were sampled; the clinical chemistry results were compared to reference intervals from the fish raised in high-density tanks. Differences were noted in plasma protein, calcium and phosphorus concentrations, such that reference intervals for high-density production tilapia were not applicable to fish raised under different environmental and management conditions.
Implementing virtual microscopy improves outcomes in a hematology morphology course.
Brueggeman, Mauri S; Swinehart, Cheryl; Yue, Mary Jane; Conway-Klaassen, Janice M; Wiesner, Stephen M
2012-01-01
In this study, we evaluated the efficacy of virtual microscopy as the primary mode of laboratory instruction in undergraduate level clinical hematology teaching. Distance education (DE) has become a popular option for expanding education and optimizing expenses but continues to be controversial. The challenge of delivering an equitable curriculum to distant locations along with the need to preserve our slide collection directed our effort to digitize the slide sets used in our teaching laboratories. Students enrolled at two performance sites were randomly assigned to either traditional microscopy (TM) or virtual microscopy (VM) instruction. The VM group performed significantly better than the TM group. We anticipate that this approach will play a central role in the distributed delivery of hematology through distance education as new programs are initiated to address workforce shortage needs.
Nursing diagnoses (NANDA-I) in hematology-oncology: a Delphi-study.
Speksnijder, Herma T; Mank, Arno P; van Achterberg, Theo
2011-01-01
To identify NANDA-I diagnoses that are most relevant to hematology-oncology nursing in Europe. In a two-round, electronic, quantitative Delphi study, 28 experts from nine European countries assessed the relevance of NANDA-I diagnoses and health problems. This study identified 64 relevant diagnoses and three health problems. All experts listed 11 diagnoses: "imbalanced nutrition: less than body requirements,"diarrhea,"fatigue,"risk for bleeding,"risk for infection,"impaired oral mucous membrane,"risk for impaired skin integrity,"impaired skin integrity,"hyperthermia,"nausea,"acute pain," and the health problem "pruritis." The "NANDA-I classification 2009-2011" describes, in almost all disease- and treatment-related problems, nursing diagnoses as relevant to the adult patient with hematological malignancy. These diagnoses are therefore recommended. © 2011, The Authors. International Journal of Nursing Terminologies and Classifications © 2011, NANDA International.
NASA Astrophysics Data System (ADS)
Burba, G. G.; Kathilankal, J. C.; Begashaw, I.; Franzen, D.; Welles, J.; McDermitt, D. K.
2017-12-01
Spatial and temporal flux data coverage have improved significantly in recent years, due to standardization, automation and management of data collection, and better handling of the generated data. With more stations and networks, larger data streams from each station, and smaller operating budgets, modern tools are required to effectively and efficiently handle the entire process.These tools should produce standardized verifiable datasets, and provide a way to cross-share the standardized data with external collaborators to leverage available funding, and promote data analyses and publications. In 2015, new open-path and enclosed flux measurement systems1 were developed, based on established gas analyzer models2,3, with the goal of improving stability in the presence of contamination, refining temperature control and compensation, and providing more accurate gas concentration measurements. In 2017, the new open-path system was further refined to simplify hardware configuration, and to reduce power consumption and cost. Additionally, all new systems incorporate complete automated on-site flux calculations using EddyPro® Software4 run by a weatherized remotely-accessible microcomputer to provide standardized traceable data sets for fluxes and supporting variables. This presentation will describe details and results from the field tests of the new flux systems, in comparison to older models and reference instruments. References:1 Burba G., W. Miller, I. Begashaw, G. Fratini, F. Griessbaum, J. Kathilankal, L. Xu, D. Franz, E. Joseph, E. Larmanou, S. Miller, D. Papale, S. Sabbatini, T. Sachs, R. Sakai, D. McDermitt, 2017. Comparison of CO2 Concentrations, Co-spectra and Flux Measurements between Latest Standardized Automated CO2/H2O Flux Systems and Older Gas Analysers. 10th ICDC Conference, Switzerland: 21-25/08 2 Metzger, S., G. Burba, S. Burns, P. Blanken, J. Li, H. Luo, R. Zulueta, 2016. Optimization of an enclosed gas analyzer sampling system for measuring eddy
Automated Image Analysis Corrosion Working Group Update: February 1, 2018
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wendelberger, James G.
These are slides for the automated image analysis corrosion working group update. The overall goals were: automate the detection and quantification of features in images (faster, more accurate), how to do this (obtain data, analyze data), focus on Laser Scanning Confocal Microscope (LCM) data (laser intensity, laser height/depth, optical RGB, optical plus laser RGB).
Anderson, E T; Stoskopf, M K; Morris, J A; Clarke, E O; Harms, C A
2010-12-01
The red lionfish Pterois volitans is important not only in the aquarium trade but also as an invasive species in the western Atlantic. Introduced to waters off the southeastern coast of the United States, red lionfish have rapidly spread along much of the East Coast and throughout Bermuda, the Bahamas, and much of the Caribbean. Hematology and plasma biochemistry were evaluated in red lionfish captured from the offshore waters of North Carolina to establish baseline parameters for individual and population health assessment. Blood smears were evaluated for total and differential white blood cell counts, and routine clinical biochemical profiles were performed on plasma samples. To improve the interpretive value of routine plasma biochemistry profiles, tissue enzyme activities (alkaline phosphatase [ALP], alanine aminotransferase [ALT], aspartate aminotransferase [AST], gamma-glutamyl transferase [GGT], lactate dehydrogenase [LD], and creatine kinase [CK]) were analyzed from liver, kidney, skeletal muscle, gastrointestinal tract, and heart tissues from five fish. The hematological and plasma biochemical values were similar to those of other marine teleosts except that the estimated white blood cell counts were much lower than those routinely found in many species. The tissue enzyme activity findings suggest that plasma LD, CK, and AST offer clinical relevance in the assessment of red lionfish.
Watkins, Patricia L; Watkins, John M
2013-02-01
Established risk factors for hematologic cancers include exposure to ionizing radiation, organic solvents, and genetic mutation; however, the potential roles of environmental and sociological factors are not well explored. As North Dakota engages in significant agricultural activity, the present investigation seeks to determine whether an association exists between the incidence of hematologic cancers and either population density or agricultural occupation for residents of south central North Dakota. The present study is a retrospective analysis. Cases of hematologic malignancies and associated pre-malignant conditions were collected from the regional Central North Dakota Cancer Registry, and analysis of study-specific demographic factors was performed. Significantly higher incidence of hematologic cancers and pre-malignant disorders was associated with residence in an "urban" county and rural city/town. Within the latter designation, there was a higher rate of self-reported agricultural occupation (40% vs 10%, P < 0.0001). The increased incidence of hematologic cancer in low population density areas of south central North Dakota supports the need for more detailed prospective research centered on agricultural exposures.
Beck, W; Gobatto, Claudio Alexandre
2013-12-01
The aims of this study were: a) to analyze the time of day effect on the aerobic capacity and time to exhaustion at aerobic capacity intensity (TE), and b) to analyze the physiological impact of handling and exercise testing during the light and dark periods, based on hematological parameters. Eighty rats were randomly divided into two control groups (C12 and C20) and two exercise groups (E12 and E20), assessed at 12:00 h (C12 and E12) or 20:00 h (C20 and E20). The lactate minimum intensity (LMi) was measured and after 48 h the exercise groups were subjected to a bout of swimming until exhaustion at LMi (TE). The TE was 1.30 ± 0.51 h for the E12 group and 1.81 ± 0.77 h for the E20 group (p = 0.03). The time of day effect was significant for all white blood cell counts (12:00 h > 20:00 h). Chronic handling and performing exercise tests at 12:00 h (light period) resulted in an increased WBC counts and decreased exercise tolerance. The favorable time of day for aerobic capacity and performance assessment and hematological parameters was at 20:00 h (dark period), which is associated with the wakefulness period of the assessed animals.
Using artificial intelligence to automate remittance processing.
Adams, W T; Snow, G M; Helmick, P M
1998-06-01
The consolidated business office of the Allegheny Health Education Research Foundation (AHERF), a large integrated healthcare system based in Pittsburgh, Pennsylvania, sought to improve its cash-related business office activities by implementing an automated remittance processing system that uses artificial intelligence. The goal was to create a completely automated system whereby all monies it processed would be tracked, automatically posted, analyzed, monitored, controlled, and reconciled through a central database. Using a phased approach, the automated payment system has become the central repository for all of the remittances for seven of the hospitals in the AHERF system and has allowed for the complete integration of these hospitals' existing billing systems, document imaging system, and intranet, as well as the new automated payment posting, and electronic cash tracking and reconciling systems. For such new technology, which is designed to bring about major change, factors contributing to the project's success were adequate planning, clearly articulated objectives, marketing, end-user acceptance, and post-implementation plan revision.
Radioimmunotherapy for treatment of B-cell lymphomas and other hematologic malignancies.
Park, Steven I; Press, Oliver W
2007-11-01
Radioimmunotherapy has emerged as one of the most promising treatment options for hematologic malignancies. This review will present the latest information on radioimmunotherapy for treatment of hematologic malignancies in various clinical settings and assess its long-term safety profile. Recent data suggest that radioimmunotherapy with 131I-tositumomab or 90Y-ibritumomab tiuxetan not only induces high response rates but also results in durable remissions in patients with relapsed or refractory indolent non-Hodgkin's lymphomas. Even more notable response rates have been observed when radioimmunotherapy is used as front-line treatment in patients with indolent non-Hodgkin's lymphomas. The use of radioimmunotherapy has been evaluated in the treatment of aggressive lymphomas with promising results, but it remains investigational. Standard doses of radioimmunotherapy given as a conditioning regimen for hematopoietic stem-cell transplant or myeloablative doses of radioimmunotherapy given in conjunction with stem-cell support have yielded encouraging outcomes with durable remissions and a low incidence of treatment-related mortality. The safety and efficacy of radioimmunotherapy has been demonstrated for patients with B-cell lymphomas and other hematologic malignancies in various clinical settings. A number of randomized phase III clinical trials are currently underway to further define radioimmunotherapy's role in the treatment of lymphomas.
Patients' reflections on communication in the second-opinion hematology-oncology consultation.
Goldman, Roberta E; Sullivan, Amy; Back, Anthony L; Alexander, Stewart C; Matsuyama, Robin K; Lee, Stephanie J
2009-07-01
The nature of communication between patients and their second-opinion hematology consultants may be very different in these one-time consultations than for those that are within long-term relationships. This study explored patients' perceptions of their second-opinion hematology-oncology consultation to investigate physician-patient communication in malignant disease at a critical juncture in cancer patients' care and decision-making. In-depth telephone interviews with a subset of 20 patients from a larger study, following their subspecialty hematology consultations. Most patients wanted to contribute to the consultation agenda, but were unable to do so. Patients sought expert and honest advice delivered with empathy, though most did not expect the consultant to directly address their emotions. They wanted the physician to apply his/her knowledge to the specifics of their individual cases, and were disappointed and distrustful when physicians cited only general prognostic statistics. In contrast, physicians' consideration of the unique elements of patients' cases, and demonstrations of empathy and respect made patients' feel positively about the encounter, regardless of the prognosis. Patients provided concrete recommendations for physician and patient behaviors to enhance the consultation. Consideration of these recommendations may result in more effective communication and increased patient satisfaction with medical visits.
Complacency and Automation Bias in the Use of Imperfect Automation.
Wickens, Christopher D; Clegg, Benjamin A; Vieane, Alex Z; Sebok, Angelia L
2015-08-01
We examine the effects of two different kinds of decision-aiding automation errors on human-automation interaction (HAI), occurring at the first failure following repeated exposure to correctly functioning automation. The two errors are incorrect advice, triggering the automation bias, and missing advice, reflecting complacency. Contrasts between analogous automation errors in alerting systems, rather than decision aiding, have revealed that alerting false alarms are more problematic to HAI than alerting misses are. Prior research in decision aiding, although contrasting the two aiding errors (incorrect vs. missing), has confounded error expectancy. Participants performed an environmental process control simulation with and without decision aiding. For those with the aid, automation dependence was created through several trials of perfect aiding performance, and an unexpected automation error was then imposed in which automation was either gone (one group) or wrong (a second group). A control group received no automation support. The correct aid supported faster and more accurate diagnosis and lower workload. The aid failure degraded all three variables, but "automation wrong" had a much greater effect on accuracy, reflecting the automation bias, than did "automation gone," reflecting the impact of complacency. Some complacency was manifested for automation gone, by a longer latency and more modest reduction in accuracy. Automation wrong, creating the automation bias, appears to be a more problematic form of automation error than automation gone, reflecting complacency. Decision-aiding automation should indicate its lower degree of confidence in uncertain environments to avoid the automation bias. © 2015, Human Factors and Ergonomics Society.
Hematological Adverse Events in Clozapine-Treated Children and Adolescents
ERIC Educational Resources Information Center
Gerbino-Rosen, Ginny; Roofeh, David; Tompkins, D. Andrew; Feryo, Doug; Nusser, Laurie; Kranzler, Harvey; Napolitano, Barbara; Frederickson, Anne; Henderson, Inika; Rhinewine, Joe; Kumra, Sanjiv
2005-01-01
Objective: To retrospectively examine rates of hematological adverse events (HAEs) in psychiatrically ill, hospitalized children treated with clozapine. Method: Clozapine treatment was administered in an open-label fashion using a flexible titration schedule, and data from weekly complete blood counts was obtained. The rate of neutropenia and…
A Study Analyzing the Career Path of Librarians
ERIC Educational Resources Information Center
Noh, Younghee
2010-01-01
This study aims to identify the career movement patterns of librarians, analyze factors influencing their career movements, and compare differences in such factors between librarians and chief librarians. Findings showed that the jobs with the highest retention rate were those in public libraries, that library automation system developers showed…
Adipocyte-derived players in hematologic tumors: useful novel targets?
Jöhrer, Karin; Ploner, Christian; Thangavadivel, Shanmugapriya; Wuggenig, Philipp; Greil, Richard
2015-01-01
Adipocytes and their products play essential roles in tumor establishment and progression. As the main cellular component of the bone marrow, adipocytes may contribute to the development of hematologic tumors. This review summarizes experimental data on adipocytes and their interaction with various cancer cells. Special focus is set on the interactions of bone marrow adipocytes and normal and transformed cells of the hematopoietic system such as myeloma and leukemia cells. Current in vitro and in vivo data are summarized and the potential of novel therapeutic targets is critically discussed. Targeting lipid metabolism of cancer cells and adipocytes in combination with standard therapeutics might open novel therapeutic avenues in these cancer entities. Adipocyte-derived products such as free fatty acids and specific adipokines such as adiponectin may be vital anti-cancer targets in hematologic malignancies. However, available data on lipid metabolism is currently mostly referring to peripheral fat cell/cancer cell interactions and results need to be evaluated specifically for the bone marrow niche.
Dai, Qingkai; Jiang, Yongmei; Shi, Hua; Zhou, Wei; Zhou, Shengjie; Yang, Hui
2014-01-01
Urinary tract infection (UTI) is a widespread disease in women. Urine culture is still the "gold standard" diagnostic test for UTI, but most of them are negative. To reduce unnecessary culture, we evaluated the automated urine particle analyzer UF-1000i screening for UTI in nonpregnant women. The urine specimens submitted to our laboratory were submitted for culture and tested by the Sysmex UF-1000i. Bacteria and white blood cell (WBC) counts were compared to standard urine culture results to assess the best cutoff values. In this study, 272 urine samples were included, of which 98 (36.0%) were culture positive with a bacterial cutoff value of 10 x 10(5) CFU/mL. A combination of bacterial (> 95/microL) and/or WBC count (> 24/microL) provided the best screening for UTI, with a sensitivity of 0.99 and a specificity of 0.82 compared with the urine culture. Sysmex UF-1000i could be used as a screening test for UTI in nonpregnant women. According to the distribution and range of the bacterial scattergram, we could primarily identify and differentiate between Gram-negative and Gram-positive bacteria.
NASA Astrophysics Data System (ADS)
Vogelaere, P.; Brasseur, M.; Quirion, A.; Leclercq, R.; Laurencelle, L.; Bekaert, S.
1990-03-01
The affect of negative thermal stress on hematological variables at rest, and during submaximal (sub ex) and maximal exercise (max ex) were observed for young males who volunteered in two experimental sessions, performed in cold (0°C) and in normal room temperature (20°C). At rest, hematological variables such as RBC and derivates Hb and Hct were significantly increased ( P<0.05) during cold stress exposure, while plasma volume decreased. The findings of this study suggest that the major factor inducing hypovolemia during low thermal stress can be imputed to local plasma water-shift mechanisms and especially to a transient shift of plasma water from intrato extravascular compartments. Rest values for WBC and platelets (Pla) were also slightly increased during cold stress exposure. However this increase can partly be related to hemoconcentration but also to the cold induced hyperventilation activating the lung circulation. Maximal exhaustive exercise induced, in both experimental temperatures, significant ( P<0.05) increments of RBC, Hb, Hct, and WBC while plasma volume decreased. However, Pla increase was less marked. On the other hand, cold stress raised slightly the observed variations of the different hematological variables. Submaximal exercise induced a similar, though non-significant, pattern for the different hematological variables in both experimental conditions. Observed plasma volume (Δ PV%) reduction appears during exercise. However cold stress induced resting plasma volume variations that are transferred at every exercise level. Neither exercise nor cold inducement significantly modified the hematological indices (MCH, MCV, MCHC). In conclusion hematological variables are affected by cold stress exposure, even when subjects perform a physical activity.
Mock, Ulrike; Nickolay, Lauren; Philip, Brian; Cheung, Gordon Weng-Kit; Zhan, Hong; Johnston, Ian C D; Kaiser, Andrew D; Peggs, Karl; Pule, Martin; Thrasher, Adrian J; Qasim, Waseem
2016-08-01
Novel cell therapies derived from human T lymphocytes are exhibiting enormous potential in early-phase clinical trials in patients with hematologic malignancies. Ex vivo modification of T cells is currently limited to a small number of centers with the required infrastructure and expertise. The process requires isolation, activation, transduction, expansion and cryopreservation steps. To simplify procedures and widen applicability for clinical therapies, automation of these procedures is being developed. The CliniMACS Prodigy (Miltenyi Biotec) has recently been adapted for lentiviral transduction of T cells and here we analyse the feasibility of a clinically compliant T-cell engineering process for the manufacture of T cells encoding chimeric antigen receptors (CAR) for CD19 (CAR19), a widely targeted antigen in B-cell malignancies. Using a closed, single-use tubing set we processed mononuclear cells from fresh or frozen leukapheresis harvests collected from healthy volunteer donors. Cells were phenotyped and subjected to automated processing and activation using TransAct, a polymeric nanomatrix activation reagent incorporating CD3/CD28-specific antibodies. Cells were then transduced and expanded in the CentriCult-Unit of the tubing set, under stabilized culture conditions with automated feeding and media exchange. The process was continuously monitored to determine kinetics of expansion, transduction efficiency and phenotype of the engineered cells in comparison with small-scale transductions run in parallel. We found that transduction efficiencies, phenotype and function of CAR19 T cells were comparable with existing procedures and overall T-cell yields sufficient for anticipated therapeutic dosing. The automation of closed-system T-cell engineering should improve dissemination of emerging immunotherapies and greatly widen applicability. Copyright © 2016. Published by Elsevier Inc.
The desire for shared decision making among patients with solid and hematological cancer.
Ernst, Jochen; Kuhnt, Susanne; Schwarzer, Andreas; Aldaoud, Ali; Niederwieser, Dietger; Mantovani-Löffler, Luisa; Kuchenbecker, Doris; Schröder, Christina
2011-02-01
The desire for shared decision making arises especially for frequently occurring cases of solid cancer. For hematological cancer conditions, there are no analogous results. This study compares the participation patients' desires concerning medical decisions dealing with their solid and hematological tumors. The 533 inpatients with solid cancer (age<65: 61.0%; female: 39.6 %) and 177 patients with hematological cancer (inpatient: 62.1%, outpatient: 37.9%; age<65: 63.3%; female: 42.4%) were given a questionnaire after admission to a hospital or medical practice. The dependent variable was patient preference for control in decision making for eight different medical areas of decision. Descriptive results showed that patients with solid cancer had a stronger desire to participate in the decisions in six of a total of eight survey fields (p<0.01). When considering medical and socio-demographic control variables, the multivariate regression shows that the differences between the patient groups remain in all areas (p<0.01). Further predictor variables are educational background and age (p<0.05). No influence resulted from the factors of gender, medical or treatment characteristics. The results show differences between patients with hematological cancer and patients with solid tumors, and these differences concern the preference to participate in medical decisions. Hemato-oncological patients desire less active participation and prefer a more dominant role of the physician in the various areas requiring decisions. Physicians should respect this in the course of the treatment. Copyright © 2010 John Wiley & Sons, Ltd.
Automated macromolecular crystallization screening
Segelke, Brent W.; Rupp, Bernhard; Krupka, Heike I.
2005-03-01
An automated macromolecular crystallization screening system wherein a multiplicity of reagent mixes are produced. A multiplicity of analysis plates is produced utilizing the reagent mixes combined with a sample. The analysis plates are incubated to promote growth of crystals. Images of the crystals are made. The images are analyzed with regard to suitability of the crystals for analysis by x-ray crystallography. A design of reagent mixes is produced based upon the expected suitability of the crystals for analysis by x-ray crystallography. A second multiplicity of mixes of the reagent components is produced utilizing the design and a second multiplicity of reagent mixes is used for a second round of automated macromolecular crystallization screening. In one embodiment the multiplicity of reagent mixes are produced by a random selection of reagent components.
Design Automation in Synthetic Biology.
Appleton, Evan; Madsen, Curtis; Roehner, Nicholas; Densmore, Douglas
2017-04-03
Design automation refers to a category of software tools for designing systems that work together in a workflow for designing, building, testing, and analyzing systems with a target behavior. In synthetic biology, these tools are called bio-design automation (BDA) tools. In this review, we discuss the BDA tools areas-specify, design, build, test, and learn-and introduce the existing software tools designed to solve problems in these areas. We then detail the functionality of some of these tools and show how they can be used together to create the desired behavior of two types of modern synthetic genetic regulatory networks. Copyright © 2017 Cold Spring Harbor Laboratory Press; all rights reserved.
Bodini, Sergio F; Malizia, Marzio; Tortelli, Annalisa; Sanfilippo, Luca; Zhou, Xingpeng; Arosio, Roberta; Bernasconi, Marzia; Di Lucia, Stefano; Manenti, Angela; Moscetta, Pompeo
2018-08-15
A novel tool, the DAMTA analyzer (Device for Analytical Monitoring and Toxicity Assessment), designed for fully automated toxicity measurements based on luminescent bacteria as well as for concomitant determination of chemical parameters, was developed and field-tested. The instrument is a robotic water analyzer equipped with a luminometer and a spectrophotometer, integrated on a thermostated reaction plate which contains a movable carousel with 80 cuvettes. Acute toxicity is measured on-line using a wild type Photobacterium phosphoreum strain with measurable bioluminescence and unaltered sensitivity to toxicants lasting up to ten days. The EC50 values of reference compounds tested were consistent with A. fischeri and P. phosphoreum international standards and comparable to previously published data. Concurrently, a laboratory trial demonstrated the feasibility of use of the analyzer for the determination of nutrients and metals in parallel to the toxicity measurements. In a prolonged test, the system was installed only in toxicity mode at the premises of the World Fair "Expo Milano-2015″, a high security site to ensure the quality of the supplied drinking water. The monitoring program lasted for six months during which ca. 2400 toxicity tests were carried out; the results indicated a mean non-toxic outcome of -5.5 ± 6.2%. In order to warrant the system's robustness in detecting toxic substances, Zn was measured daily with highly reproducible inhibition results, 70.8 ± 13.6%. These results assure that this novel toxicity monitor can be used as an early warning system for protection of drinking water sources from emergencies involving low probability/high impact contamination events in source water or treated water. Copyright © 2018 Elsevier Inc. All rights reserved.
Complacency and bias in human use of automation: an attentional integration.
Parasuraman, Raja; Manzey, Dietrich H
2010-06-01
Our aim was to review empirical studies of complacency and bias in human interaction with automated and decision support systems and provide an integrated theoretical model for their explanation. Automation-related complacency and automation bias have typically been considered separately and independently. Studies on complacency and automation bias were analyzed with respect to the cognitive processes involved. Automation complacency occurs under conditions of multiple-task load, when manual tasks compete with the automated task for the operator's attention. Automation complacency is found in both naive and expert participants and cannot be overcome with simple practice. Automation bias results in making both omission and commission errors when decision aids are imperfect. Automation bias occurs in both naive and expert participants, cannot be prevented by training or instructions, and can affect decision making in individuals as well as in teams. While automation bias has been conceived of as a special case of decision bias, our analysis suggests that it also depends on attentional processes similar to those involved in automation-related complacency. Complacency and automation bias represent different manifestations of overlapping automation-induced phenomena, with attention playing a central role. An integrated model of complacency and automation bias shows that they result from the dynamic interaction of personal, situational, and automation-related characteristics. The integrated model and attentional synthesis provides a heuristic framework for further research on complacency and automation bias and design options for mitigating such effects in automated and decision support systems.
End-of-Life Care for Blood Cancers: A Series of Focus Groups With Hematologic Oncologists
Odejide, Oreofe O.; Salas Coronado, Diana Y.; Watts, Corey D.; Wright, Alexi A.; Abel, Gregory A.
2014-01-01
Purpose: Hematologic cancers are associated with aggressive cancer-directed care near death and underuse of hospice and palliative care services. We sought to explore hematologic oncologists' perspectives and decision-making processes regarding end-of-life (EOL) care. Methods: Between September 2013 and January 2014, 20 hematologic oncologists from the Dana-Farber/Harvard Cancer Center participated in four focus groups regarding EOL care for leukemia, lymphoma, multiple myeloma, and hematopoietic stem-cell transplantation. Focus groups employed a semistructured format with case vignettes and open-ended questions and were followed by thematic analysis. Results: Many participants felt that identifying the EOL phase for patients with hematologic cancers was challenging as a result of the continuing potential for cure with advanced disease and the often rapid pace of decline near death. This difficulty was reported to result in later initiation of EOL care. Barriers to high-quality EOL care were also reported to be multifactorial, including unrealistic expectations from both physicians and patients, long-term patient-physician relationships resulting in difficulty conducting EOL discussions, and inadequacy of existing home-based EOL services. Participants also expressed concern that some EOL quality measures developed for solid tumors may be unacceptable for patients with blood cancers given their unique needs at the EOL (eg, palliative transfusions). Conclusion: Our analysis suggests that hematologic oncologists need better clinical markers for when to initiate EOL care. In addition, current quality measures may be inappropriate for identifying overly aggressive care for patients with blood cancers. Further research is needed to develop effective interventions to improve EOL care for this patient population. PMID:25294393
Automated analysis in generic groups
NASA Astrophysics Data System (ADS)
Fagerholm, Edvard
This thesis studies automated methods for analyzing hardness assumptions in generic group models, following ideas of symbolic cryptography. We define a broad class of generic and symbolic group models for different settings---symmetric or asymmetric (leveled) k-linear groups --- and prove ''computational soundness'' theorems for the symbolic models. Based on this result, we formulate a master theorem that relates the hardness of an assumption to solving problems in polynomial algebra. We systematically analyze these problems identifying different classes of assumptions and obtain decidability and undecidability results. Then, we develop automated procedures for verifying the conditions of our master theorems, and thus the validity of hardness assumptions in generic group models. The concrete outcome is an automated tool, the Generic Group Analyzer, which takes as input the statement of an assumption, and outputs either a proof of its generic hardness or shows an algebraic attack against the assumption. Structure-preserving signatures are signature schemes defined over bilinear groups in which messages, public keys and signatures are group elements, and the verification algorithm consists of evaluating ''pairing-product equations''. Recent work on structure-preserving signatures studies optimality of these schemes in terms of the number of group elements needed in the verification key and the signature, and the number of pairing-product equations in the verification algorithm. While the size of keys and signatures is crucial for many applications, another aspect of performance is the time it takes to verify a signature. The most expensive operation during verification is the computation of pairings. However, the concrete number of pairings is not captured by the number of pairing-product equations considered in earlier work. We consider the question of what is the minimal number of pairing computations needed to verify structure-preserving signatures. We build an
[Automated analyser of organ cultured corneal endothelial mosaic].
Gain, P; Thuret, G; Chiquet, C; Gavet, Y; Turc, P H; Théillère, C; Acquart, S; Le Petit, J C; Maugery, J; Campos, L
2002-05-01
Until now, organ-cultured corneal endothelial mosaic has been assessed in France by cell counting using a calibrated graticule, or by drawing cells on a computerized image. The former method is unsatisfactory because it is characterized by a lack of objective evaluation of the cell surface and hexagonality and it requires an experienced technician. The latter method is time-consuming and requires careful attention. We aimed to make an efficient, fast and easy to use, automated digital analyzer of video images of the corneal endothelium. The hardware included a PC Pentium III ((R)) 800 MHz-Ram 256, a Data Translation 3155 acquisition card, a Sony SC 75 CE CCD camera, and a 22-inch screen. Special functions for automated cell boundary determination consisted of Plug-in programs included in the ImageTool software. Calibration was performed using a calibrated micrometer. Cell densities of 40 organ-cultured corneas measured by both manual and automated counting were compared using parametric tests (Student's t test for paired variables and the Pearson correlation coefficient). All steps were considered more ergonomic i.e., endothelial image capture, image selection, thresholding of multiple areas of interest, automated cell count, automated detection of errors in cell boundary drawing, presentation of the results in an HTML file including the number of counted cells, cell density, coefficient of variation of cell area, cell surface histogram and cell hexagonality. The device was efficient because the global process lasted on average 7 minutes and did not require an experienced technician. The correlation between cell densities obtained with both methods was high (r=+0.84, p<0.001). The results showed an under-estimation using manual counting (2191+/-322 vs. 2273+/-457 cell/mm(2), p=0.046), compared with the automated method. Our automated endothelial cell analyzer is efficient and gives reliable results quickly and easily. A multicentric validation would allow us to
Miri-Dashe, Timzing; Osawe, Sophia; Tokdung, Monday; Daniel, Monday Tokdung Nenbammun; Daniel, Nenbammun; Choji, Rahila Pam; Mamman, Ille; Deme, Kurt; Damulak, Dapus; Abimiku, Alash'le
2014-01-01
Interpretation of laboratory test results with appropriate diagnostic accuracy requires reference or cutoff values. This study is a comprehensive determination of reference values for hematology and clinical chemistry in apparently healthy voluntary non-remunerated blood donors and pregnant women. Consented clients were clinically screened and counseled before testing for HIV, Hepatitis B, Hepatitis C and Syphilis. Standard national blood donors' questionnaire was administered to consented blood donors. Blood from qualified volunteers was used for measurement of complete hematology and chemistry parameters. Blood samples were analyzed from a total of 383 participants, 124 (32.4%) males, 125 (32.6%) non-pregnant females and 134 pregnant females (35.2%) with a mean age of 31 years. Our results showed that the red blood cells count (RBC), Hemoglobin (HB) and Hematocrit (HCT) had significant gender difference (p = 0.000) but not for total white blood count (p>0.05) which was only significantly higher in pregnant verses non-pregnant women (p = 0.000). Hemoglobin and Hematocrit values were lower in pregnancy (P = 0.000). Platelets were significantly higher in females than men (p = 0.001) but lower in pregnant women (p = .001) with marked difference in gestational period. For clinical chemistry parameters, there was no significant difference for sodium, potassium and chloride (p>0.05) but gender difference exists for Bicarbonate (HCO3), Urea nitrogen, Creatinine as well as the lipids (p<0.05). Total bilirubin was significantly higher in males than females (p = 0.000). Significant differences exist for all chemistry parameters between pregnant and non-pregnant women in this study (p<0.05), except Amylase and total cholesterol (p>0.05). Hematological and Clinical Chemistry reference ranges established in this study showed significant gender differences. Pregnant women also differed from non-pregnant females and during pregnancy. This is the first of such comprehensive
Automated verification of flight software. User's manual
NASA Technical Reports Server (NTRS)
Saib, S. H.
1982-01-01
(Automated Verification of Flight Software), a collection of tools for analyzing source programs written in FORTRAN and AED is documented. The quality and the reliability of flight software are improved by: (1) indented listings of source programs, (2) static analysis to detect inconsistencies in the use of variables and parameters, (3) automated documentation, (4) instrumentation of source code, (5) retesting guidance, (6) analysis of assertions, (7) symbolic execution, (8) generation of verification conditions, and (9) simplification of verification conditions. Use of AVFS in the verification of flight software is described.
Shafee, Muhammad; Abbas, Ferhat; Ashraf, Muhammad; Alam Mengal, Mohammad; Kakar, Niamatullah; Ahmad, Zafar; Ali, Fawad
2014-01-01
Objectives: Tuberculosis (TB) is a chronic debilitating infectious disease affecting more than one third of the global population. This study was designed to investigate different peripheral blood parameters and risk factors in TB patients. Methods: A total of 600 (Male, 238 and Female, 362) aging 20-80 Years patients with clinical signs of prolonged cough, chest pain and fever, were evaluated for peripheral blood parameters using hematology analyzer. All the informations related to the disease were collected from the patients and recorded using predesigned questionnaire. Results: Erythrocytic Sedimentation Rate (ESR), Hemoglobin (Hb) and lymphocytes were markedly changed in both sexes. Hemoglobin was recorded lower than normal value in 55% and 53% of male and female population respectively. Total leukocyte count was also lower than normal values in 8% and 6% of male and female respectively. Similarly neutropenia was observed in 5% and 8% cases, while neutrophilia was recorded as 60% and 64% in male and female patients respectively. Lymphocytopenia was also observed in 59% and 43% patients in male and female respectively. Illiteracy, smoking habits, overcrowding and living in shared houses were the main associated risk factors contributing in the enhancement of the disease. Conclusion: The disease was present significantly more in females and was relatively higher in older patients. Different hematological parameters like Erythrocytic sedimentation Rate (ESR), platelets and leukocytes work as hallmark and help the clinicians in early diagnosis of the disease. Malnutrition, smoking tobacco, living in shared houses, illiteracy and poverty were the common risk factors contributing to the dissemination of the tuberculosis in the target area population. PMID:24639827
Risør, Bettina Wulff; Lisby, Marianne; Sørensen, Jan
2018-02-01
Automated medication systems have been found to reduce errors in the medication process, but little is known about the cost-effectiveness of such systems. The objective of this study was to perform a model-based indirect cost-effectiveness comparison of three different, real-world automated medication systems compared with current standard practice. The considered automated medication systems were a patient-specific automated medication system (psAMS), a non-patient-specific automated medication system (npsAMS), and a complex automated medication system (cAMS). The economic evaluation used original effect and cost data from prospective, controlled, before-and-after studies of medication systems implemented at a Danish hematological ward and an acute medical unit. Effectiveness was described as the proportion of clinical and procedural error opportunities that were associated with one or more errors. An error was defined as a deviation from the electronic prescription, from standard hospital policy, or from written procedures. The cost assessment was based on 6-month standardization of observed cost data. The model-based comparative cost-effectiveness analyses were conducted with system-specific assumptions of the effect size and costs in scenarios with consumptions of 15,000, 30,000, and 45,000 doses per 6-month period. With 30,000 doses the cost-effectiveness model showed that the cost-effectiveness ratio expressed as the cost per avoided clinical error was €24 for the psAMS, €26 for the npsAMS, and €386 for the cAMS. Comparison of the cost-effectiveness of the three systems in relation to different valuations of an avoided error showed that the psAMS was the most cost-effective system regardless of error type or valuation. The model-based indirect comparison against the conventional practice showed that psAMS and npsAMS were more cost-effective than the cAMS alternative, and that psAMS was more cost-effective than npsAMS.
Kim, Yun-Mi; Lee, Jin-A; Jung, Bock-Gie; Kim, Tae-Hoon; Lee, Bong-Joo; Suh, Guk-Hyun
2016-06-01
There are no accurate reference ranges for hematology parameters and lymphocyte subsets in Korean native beef cattle (Hanwoo). This study was performed to establish reliable reference ranges of hematology and lymphocyte subsets using a large number of Hanwoo cattle (n = 350) and to compare differences between Hanwoo and Holstein dairy cattle (n = 334). Additionally, age-related changes in lymphocyte subsets were studied. Bovine leukocyte subpopulation analysis was performed using mono or dual color flow cytometry. The leukocyte subpopulations investigated in healthy cattle included: CD2(+) cells, sIgM(+) cells, MHC class II(+) cells, CD3(+) CD4(+) cells, CD3(+) CD8(+) cells, and WC1(+) cells. Although Hanwoo and Holstein cattle are the same species, results showed several differences in hematology and lymphocyte subsets between Hanwoo and Holstein cattle. This study is the first report to establish reference ranges of hematology and lymphocyte subsets in adult Hanwoo cattle. © 2015 Japanese Society of Animal Science.
Time to look beyond one-year mortality in critically ill hematological patients?
Moors, Ine; Benoit, Dominique D
2014-02-11
The spectacular improvement in long-term prognosis of patients with hematological malignancies since the 1980s, coupled with the subsequent improvement over the past decade in short- and mid-term survival in cases of critical illness, resulted in an increasing referral of such patients to the ICU. A remaining question, however, is how these patients perform in the long term with regard to survival and quality of life. Here we discuss the present multicenter study on survival beyond 1 year in critically ill patients with hematological malignancies. We conclude with suggestions on how we can further improve the long-term outcome of these patients.
Zhang, Lei; Ye, Xin; Sun, Yi; Deng, An-mei; Qian, Bao-hua
2015-02-06
Hematologic disease affects people of all ages worldwide. In the past decade, researchers have made great progress in the field of hematology. In the present study we compared the hematology research output from China and other countries (USA, Germany, UK, Japan and South Korea) over the past 10 years and 5 years. The related articles were extracted based on the PubMed database. We recorded the number of publications, clinical trials, randomized controlled trials, meta-analyses, case reports, reviews, citations, impact factors, articles in the top 10 journals and most published journals to assess the quantity and quality of research output in each region. A total of 120,641 hematology-related articles were published from 2004 to 2013. The USA accounted for 27.13% (32,732/120,641) of the publications, followed by Germany (7,479/120,641; 6.20%), Japan (6,347/120,641; 5.26%), the UK (5,453/120,641; 4.52%), China (2,924/120,641; 2.42%) and South Korea (1,413/120,641; 1.17%). The ranking for cumulative impact factors was as follows: USA; Germany; UK; Japan; China and South Korea. The median impact factors in the UK, USA, and Germany were higher than Japan, South Korea, and China. Interestingly, the median impact factors in the three Asia countries were similar both in 2004-2013 and 2009-2013. The UK had the highest percentage of publications in the top 25% of journals, while China lagged behind and ranked last. When comparing the number of articles in the top 10 journals, the results were similar to the IF findings. Germany had the highest number of average citations, while China had the lowest number of average citation. The status of hematology research output from the 6 countries in 2009-2013 had little difference from 2004-2013. Thus, the USA has had a dominant role in hematologic research in the past 10 years. Overall, the quality of publications in European countries was better than Asia countries. Although China has made considerable progress in hematology
2014-01-01
Telomeres are specific nucleoprotein structures at the ends of eukaryotic chromosomes. Telomeres and telomere-associated proteins maintain genome stability by protecting the ends of chromosomes from fusion and degradation. In normal somatic cells, the length of the telomeres gradually becomes shortened with cell division. In tumor cells, the shortening of telomeres length is accelerated under the increased proliferation pressure. However, it will be maintained at an extremely short length as the result of activation of telomerase. Significantly shortened telomeres, activation of telomerase, and altered expression of telomere-associated proteins are common features of various hematologic malignancies and are related with progression or chemotherapy resistance in these diseases. In patients who have received hematopoietic stem cell transplantation (HSCT), the telomere length and the telomerase activity of the engrafted donor cells have a significant influence on HSCT outcomes. Transplantation-related factors should be taken into consideration because of their impacts on telomere homeostasis. As activation of telomerase is widespread in tumor cells, it has been employed as a target point in the treatment of neoplastic hematologic disorders. In this review, the characteristics and roles of telomeres and telomerase both in hematologic malignancies and in HSCT will be summarized. The current status of telomerase-targeted therapies utilized in the treatment of hematologic malignancies will also be reviewed. PMID:25139287
Two cases of paralitic ileus in onco-hematologic patients
Carraro, Francesca; Rivetti, Elisa; Romano, Erica; Fagioli, Franca
2012-01-01
Paralytic ileus is a severe complication resulting from a variety of disorders. It occurs most commonly in patients with serious underlying medical or surgical conditions. Prompt diagnosis and appropriate management may improve the outcome. We describe 2 cases of onco-hematologic patients who presented this complication after intensive chemotherapy. PMID:22690309
Solís-Marcos, Ignacio; Ahlström, Christer; Kircher, Katja
2018-05-01
To investigate the influence of prior experience with Level 2 automation on additional task performance during manual and Level 2 partially automated driving. Level 2 automation is now on the market, but its effects on driver behavior remain unclear. Based on previous studies, we could expect an increase in drivers' engagement in secondary tasks during Level 2 automated driving, but it is yet unknown how drivers will integrate all the ongoing demands in such situations. Twenty-one drivers (12 without, 9 with Level 2 automation experience) drove on a highway manually and with Level 2 automation (exemplified by Volvo Pilot Assist generation 2; PA2) while performing an additional task. In half of the conditions, the task could be interrupted (self-paced), and in the other half, it could not (system-paced). Drivers' visual attention, additional task performance, and other compensatory strategies were analyzed. Driving with PA2 led to decreased scores in the additional task and more visual attention to the dashboard. In the self-paced condition, all drivers looked more to the task and perceived a lower mental demand. The drivers experienced with PA2 used the system and the task more than the novice group and performed more overtakings. The additional task interfered more with Level 2 automation than with manual driving. The drivers, particularly the automation novice drivers, used some compensatory strategies. Automation designers need to consider these potential effects in the development of future automated systems.
Febuxostat as a Prophylaxis for Tumor Lysis Syndrome in Children with Hematological Malignancies.
Kishimoto, Kenji; Kobayashi, Ryoji; Hori, Daiki; Sano, Hirozumi; Suzuki, Daisuke; Kobayashi, Kunihiko
2017-10-01
The aim of the present study was to determine if febuxostat could prevent tumor lysis syndrome (TLS) in children who received induction chemotherapy for hematologic malignancies. A retrospective analysis was performed in 45 pediatric patients with hematological malignancies who received febuxostat (10 mg daily, n=20) or allopurinol (300 mg/m 2 daily, n=25) as a prophylaxis for TLS. A significant decrease of serum uric acid (UA) level was observed in patients with febuxostat over the first 2 days (6.6±3.8 mg/dl vs. 4.5±2.8 mg/dl, p<0.001). The febuxostat group also showed significant reduction of urinary UA/creatinine ratios during the first two days of treatment (0.98±0.85 vs. 0.51±0.26, p=0.010). No significant differences were observed between febuxostat-treated and allopurinol-treated patients regarding the percent change in serum UA level. Febuxostat had a notable effect in reducing serum UA level in children with hematological malignancies. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
The Challenge of Targeting Notch in Hematologic Malignancies
Hernandez Tejada, Fiorela N.; Galvez Silva, Jorge R.; Zweidler-McKay, Patrick A.
2014-01-01
Notch signaling can play oncogenic and tumor suppressor roles depending on cell type. Hematologic malignancies encompass a wide range of transformed cells, and consequently the roles of Notch are diverse in these diseases. For example Notch is a potent T-cell oncogene, with >50% of T-cell acute lymphoblastic leukemia (T-ALL) cases carry activating mutations in the Notch1 receptor. Targeting Notch signaling in T-ALL with gamma-secretase inhibitors, which prevent Notch receptor activation, has shown pre-clinical activity, and is under evaluation clinically. In contrast, Notch signaling inhibits acute myeloblastic leukemia growth and survival, and although targeting Notch signaling in AML with Notch activators appears to have pre-clinical activity, no Notch agonists are clinically available at this time. As such, despite accumulating evidence about the biology of Notch signaling in different hematologic cancers, which provide compelling clinical promise, we are only beginning to target this pathway clinically, either on or off. In this review, we will summarize the evidence for oncogenic and tumor suppressor roles of Notch in a wide range of leukemias and lymphomas, and describe therapeutic opportunities for now and the future. PMID:24959528
Nathan, Paul C; Schiffman, Joshua D; Huang, Sujuan; Landier, Wendy; Bhatia, Smita; Eshelman-Kent, Debra; Wright, Jennifer; Oeffinger, Kevin C; Hudson, Melissa M
2011-12-15
Childhood cancer survivors require life-long care by clinicians with an understanding of the specific risks arising from the prior cancer and its therapy. We surveyed North American pediatric hematology/oncology training programs to evaluate their resources and capacity for educating medical trainees about survivorship. An Internet survey was sent to training program directors and long-term follow-up clinic (LTFU) directors at the 56 US and Canadian centers with pediatric hematology/oncology fellowship programs. Perceptions regarding barriers to and optimal methods of delivering survivorship education were compared among training program and LTFU clinic directors. Responses were received from 45/56 institutions of which 37/45 (82%) programs require that pediatric hematology/oncology fellows complete a mandatory rotation focused on survivorship. The rotation is 4 weeks or less in 21 programs. Most (36/45; 80%) offer didactic lectures on survivorship as part of their training curriculum, and these are considered mandatory for pediatric hematology/oncology fellows at 26/36 (72.2%). Only 10 programs (22%) provide training to medical specialty trainees other than pediatric hematology/oncology fellows. Respondents identified lack of time for trainees to spend learning about late effects as the most significant barrier to providing survivorship teaching. LTFU clinic directors were more likely than training program directors to identify lack of interest in survivorship among trainees and survivorship not being a formal or expected part of the fellowship training program as barriers. The results of this survey highlight the need to establish standard training requirements to promote the achievement of basic survivorship competencies by pediatric hematology/oncology fellows. Copyright © 2011 Wiley Periodicals, Inc.
Improving the driver-automation interaction: an approach using automation uncertainty.
Beller, Johannes; Heesen, Matthias; Vollrath, Mark
2013-12-01
The aim of this study was to evaluate whether communicating automation uncertainty improves the driver-automation interaction. A false system understanding of infallibility may provoke automation misuse and can lead to severe consequences in case of automation failure. The presentation of automation uncertainty may prevent this false system understanding and, as was shown by previous studies, may have numerous benefits. Few studies, however, have clearly shown the potential of communicating uncertainty information in driving. The current study fills this gap. We conducted a driving simulator experiment, varying the presented uncertainty information between participants (no uncertainty information vs. uncertainty information) and the automation reliability (high vs.low) within participants. Participants interacted with a highly automated driving system while engaging in secondary tasks and were required to cooperate with the automation to drive safely. Quantile regressions and multilevel modeling showed that the presentation of uncertainty information increases the time to collision in the case of automation failure. Furthermore, the data indicated improved situation awareness and better knowledge of fallibility for the experimental group. Consequently, the automation with the uncertainty symbol received higher trust ratings and increased acceptance. The presentation of automation uncertaintythrough a symbol improves overall driver-automation cooperation. Most automated systems in driving could benefit from displaying reliability information. This display might improve the acceptance of fallible systems and further enhances driver-automation cooperation.
Saheed, Sabiu; Oladipipo, Ajani E; Abdulazeez, Abubakar A; Olarewaju, Sulyman A; Ismaila, Nurain O; Emmanuel, Irondi A; Fatimah, Quadri D; Aisha, Abubakar Y
2015-01-01
Despite the acclaimed phytotherapeutic attributes of Stigma maydis in folkloric medicine, there is paucity of information on its toxicity profile on hematological and lipid parameters. The toxicological effect of aqueous extract of corn silk at 100, 200 and 400 mg/kg body weight on hematological indices in Wistar rats were evaluated progressively at 24 h after 1, 7, 14, 21 and 28 days. Lipid parameters were also analyzed at the end of the experimental period. We observed that the extract did not exhibit any significant ( p > 0.05) effect on red blood cells, hematocrit, hemoglobin, mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, and mean platelet volume at all the tested doses. The study however showed a significant increase in the serum levels of white blood cell, platelet, lymphocytes, high-density lipoprotein cholesterol; as well as feeding pattern in the animals, while the concentrations of total cholesterol, low-density lipoprotein cholesterol, and artherogenic index value were significantly lowered. These findings are suggestive of non-hematotoxic potential of the extract. Overall, the effect exhibited by corn silk extract in this study proved that, it is unlikely to be hematotoxic and could be a good candidature in the management of coronary heart diseases if consumed at the doses investigated.
[Standardization of operation monitoring and control of the clinical laboratory automation system].
Tao, R
2000-10-01
Laboratory automation systems showed up in the 1980s and have been introduced to many clinical laboratories since early 1990s. Meanwhile, it was found that the difference in the specimen tube dimensions, specimen identification formats, specimen carrier transportation equipment architecture, electromechanical interfaces between the analyzers and the automation systems was preventing the systems from being introduced to a wider extent. To standardize the different interfaces and reduce the cost of laboratory automation, NCCLS and JCCLS started establishing standards for laboratory automation in 1996 and 1997 respectively. Operation monitoring and control of the laboratory automation system have been included in their activities, resulting in the publication of an NCCLS proposed standard in 1999.
Promsuwicha, Orathai; Kankhao, Supattra; Songmuang, Wayuree; Auewarakul, Chirayu U
2014-12-01
Diagnosis of hematologic malignancies requires a multidisciplinary approach. Flow cytometry (FCM) has become an essential tool for immunophenotypic studies of malignant hematopoietic cells. To evaluate the utilization trend of FCM and its diagnostic yields for hematologic malignancy at a major teaching hospital in Thailand. FCM results of bone marrow (BM) and peripheral blood (PB) specimens during 2000-2013 were analyzed and compared to clinical diagnosis. Overall, 7,982 specimens were submitted for diagnostic FCM including 6,561 BM and 1,421 PB. The number of specimens analyzedwas 121, 142, 164, 299, 491, 431, 690, 611, 719, 744, 725, 863, 955 and 1,027, respectively, from 2000 to 2013. The most common clinical diagnoses requested for FCM were acute leukemia (5,911 cases, 74%) followed by lymphoma (1,419 cases, 17.8%), and chronic lymphocytic leukemia (CLL) (634 cases, 7.94%). The highest diagnostic yield of FCM was found in acute leukemia cases (69.71%) followed by CLL (35.33%). Only 15.43% of clinically suspected lymphoma cases were positive by FCM. Overutilization of PB (35.6% of cases) instead of BM for lymphoma staging significantly contributed to low diagnostic yields of lymphoma by FCM as circulating tumor cells may not be present in such cases. FCM has an increasing role in the diagnosis of hematologic malignancies in Thai patients over the past 14 years with the highest diagnostic yield in acute leukemia. Appropriate specimen types and study indications are required in order to reduce futility of costly diagnostic tests and improve diagnostic yields.
Tsuda, Kenji; Sudo, Kazuaki; Goto, Goro; Takai, Makiko; Itokawa, Tatsuo; Isshiki, Takahiro; Takei, Naoko; Tanimoto, Tetsuya; Komatsu, Tsunehiko
2016-01-01
Adherence to rehabilitation exercise is much lower in patients with hematologic malignancies (22.5-45.8%) than in patients with solid tumors (60-85%) due to the administration of more intensive chemotherapeutic regimens in the former. Virtual reality exercise can be performed even in a biological clean room and it may improve the adherence rates in elderly patients with hematologic malignancies. Thus, in this pilot study, we aimed to investigate the feasibility and safety of virtual reality exercise intervention using Nintendo Wii Fit in patients with hematologic malignancies receiving chemotherapy. In this feasibility study, 16 hospitalized patients with hematologic malignancies aged ≥60 years performed virtual reality exercise for 20 minutes using the Nintendo Wii Fit once a day, five times a week, from the start of chemotherapy until hospital discharge. The adherence rate, safety, and physical and psychological performances were assessed. The adherence rate for all 16 patients was 66.5%. Nine patients completed the virtual reality exercise intervention with 88 sessions, and the adherence rate was 62.0%. No intervention-related adverse effects >Grade 2, according to National Cancer Institute Common Terminology Criteria for Adverse Events version 3.0, were observed. We noted maintenance of the physical performance (e.g., Barthel index, handgrip strength, knee extension strength, one-leg standing time, and the scores of timed up and go test and Instrumental Activities of Daily Living) and psychosocial performance (e.g., score of hospital anxiety and depression scale). Virtual reality exercise using the Wii Fit may be feasible, safe and efficacious, as demonstrated in our preliminary results, for patients with hematologic malignancies receiving chemotherapy.
Baker, Thomas M.; Satlin, Michael J.
2016-01-01
Prolonged neutropenia and chemotherapy-induced mucositis render patients with hematologic malignancies highly vulnerable to Gram-negative bacteremia. Unfortunately, multidrug-resistant (MDR) Gram-negative bacteria are increasingly encountered globally, and current guidelines for empirical antibiotic coverage in these patients may not adequately treat these bacteria. This expansion of resistance, coupled with traditional culturing techniques requiring 2-4 days for bacterial identification and antimicrobial susceptibility results, have grave implications for these immunocompromised hosts. This review characterizes the epidemiology, risk factors, resistance mechanisms, recommended treatments, and outcomes of the MDR Gram-negative bacteria that commonly cause infections in patients with hematologic malignancies. We also examine infection prevention strategies in hematology patients, such as infection control practices, antimicrobial stewardship, and targeted decolonization. Finally, we assess strategies to improve outcomes of infected patients, including gastrointestinal screening to guide empirical antibiotic therapy, new rapid diagnostic tools for expeditious identification of MDR pathogens, and use of two new antimicrobial agents, ceftolozane/tazobactam and ceftazidime/avibactam. PMID:27339405
Eghrari, Allen O.; Mumtaz, Aisha A.; Garrett, Brian; Rezaei, Mahsa; Akhavan, Mina S.; Riazuddin, S. Amer; Gottsch, John D.
2016-01-01
Purpose Retroillumination photography analysis (RPA) is an objective tool for assessment of the number and distribution of guttae in eyes affected with Fuchs Corneal Dystrophy (FCD). Current protocols include manual processing of images; here we assess validity and interrater reliability of automated analysis across various levels of FCD severity. Methods Retroillumination photographs of 97 FCD-affected corneas were acquired and total counts of guttae previously summated manually. For each cornea, a single image was loaded into ImageJ software. We reduced color variability and subtracted background noise. Reflection of light from each gutta was identified as a local area of maximum intensity and counted automatically. Noise tolerance level was titrated for each cornea by examining a small region of each image with automated overlay to ensure appropriate coverage of individual guttae. We tested interrater reliability of automated counts of guttae across a spectrum of clinical and educational experience. Results A set of 97 retroillumination photographs were analyzed. Clinical severity as measured by a modified Krachmer scale ranged from a severity level of 1 to 5 in the set of analyzed corneas. Automated counts by an ophthalmologist correlated strongly with Krachmer grading (R2=0.79) and manual counts (R2=0.88). Intraclass correlation coefficient demonstrated strong correlation, at 0.924 (95% CI, 0.870- 0.958) among cases analyzed by three students, and 0.869 (95% CI, 0.797- 0.918) among cases for which images was analyzed by an ophthalmologist and two students. Conclusions Automated RPA allows for grading of FCD severity with high resolution across a spectrum of disease severity. PMID:27811565
Effects of occupational exposure of X-Ray on hematological parameters of diagnostic technicians
NASA Astrophysics Data System (ADS)
Taqi, Ali H.; Faraj, Kharman A.; Zaynal, Sarah A.; Hameed, Ahmed M.; Mahmood, Abd-Alkader A.
2018-06-01
The aim of this study was to identify the effects of long term exposure of X-ray on diagnostic technicians which they work at Kirkuk hospitals through examining some hematological parameters which are white blood cells (WBC), Neutrophils, Lymphocyte, Monocyte, Eosinophil, Basophil, Reactive Lymphocyte, red blood cells (RBC), hemoglobin (Hb), hematocrit (HCT), Mean Cell Volume (MCV), Mean Corpuscular Hemoglobin (MCH), Mean Cell Hemoglobin Concentration (MCHC), Red Cell Distribution Width (RDW), Platelet (PLT). The study included 54 male diagnostic technicians and 54 male healthy controls match with the first group to show any alteration of the hematological parameters. The diagnostic technicians divided into two groups depending on their work experience and hours working per day. The statistical analysis was performed using (Graph-pad) program. Our results showed that the Complete blood cells count (CBC) parameters (Neutrophil, Monocytes, Basophile, MCV, RDW and PLT) significantly (P<.05) decreased while the parameters (Lymphocytes, RBC, Hb and HCT) significantly (P<.05) increased and strong significantly (P<.0001) increasing was recorded for the parameter Reactive lymphocytes mostly in all groups of the diagnostic technicians compared with their controls. We concluded that chronic exposure of X-ray can significantly alter some hematological parameters and the number of hours working per day has observable effects on the some hematological parameters. We recommended training and courses about hazard of ionizing radiation should be organized for enhance the healthcare quality of the technicians and to improve their knowledge about benefit of radiation protection tools to protect themselves from any overexposure during the daily life.
Kakizoe, Yuka; Sakaoka, Ken; Kakizoe, Futoshi; Yoshii, Makoto; Nakamura, Hitoshi; Kanou, Yoshihiko; Uchida, Itaru
2007-03-01
Hematologic characteristics and plasma chemistry values of juvenile loggerhead turtles (Caretta caretta) from the ages of 1 mo to 3 yr were obtained to establish baseline values. Five clinically normal loggerhead turtles were selected from the same clutch and raised in an indoor artificial nesting beach. Blood samples were successively collected and examined for various blood characteristics for a maximum total of 15 times. Hematologic characteristics, including packed cell volume, white blood cell counts, and white blood cell differentials; and plasma chemistry values, including total bilirubin, total protein, albumin, glutamic oxaloacetic transaminase, glutamic pyruvic transaminase, gamma-glutamic transpeptidase, creatinine, blood urea nitrogen, uric acid, alkaline phosphatase, amylase, triglyceride, total cholesterol, ionized sodium, ionized potassium and ionized chlorine, were measured. These results were used to establish a hematology and blood chemistry baseline for captive juvenile loggerhead turtles and will aid in their medical management.
Automated longwall guidance and control systems, phase 1
NASA Technical Reports Server (NTRS)
Rybak, S. C.
1978-01-01
Candidate vertical control systems (VCS) and face advancement systems (FAS) required to satisfactorily automate the longwall system were analyzed and simulated in order to develop an overall longwall system configuration for preliminary design.
Hematological, oxidative stress, and immune status profiling in elite combat sport athletes.
Dopsaj, Violeta; Martinovic, Jelena; Dopsaj, Milivoj; Kasum, Goran; Kotur-Stevuljevic, Jelena; Koropanovski, Nenad
2013-12-01
The aim of this study was to profile hematological, oxidative stress, and immunological parameters in male athletes who practiced combat sports and to determine whether the type of combat sport influenced the measured parameters. Eighteen karate professionals, 15 wrestlers, and 14 kickboxers participated in the study. Hematological, iron-related, oxidative stress, and immunological parameters were measured at the beginning of a precompetitive period. The general linear model showed significant differences between the karate professionals, wrestlers, and kickboxers with respect to their hematological and iron status parameters (Wilks' Lambda = 0.270, F = 2.186, p < 0.05) and oxidative stress status (Wilks' Lambda = 0.529, F = 1.940, p < 0.05). The immature reticulocyte fraction was significantly higher in wrestlers (0.30 ± 0.03) compared with kickboxers (0.24 ± 0.04; p < 0.05) and karate professionals (0.26 ± 0.04; p < 0.05). Low hemoglobin density was significantly lower in wrestlers and kickboxers (p < 0.05) compared with karate professionals (karate: 3.51 ± 1.19, wrestlers: 1.95 ± 1.10, and kickboxers: 1.77 ± 0.76). Significant differences were observed between the karate professionals and wrestlers with respect to their pro-oxidant-antioxidant balance (437 ± 103 vs. 323 ± 148, p < 0.05) and superoxide-dismutase activity (SOD) (73 ± 37 vs. 103 ± 30, p < 0.05). All the measured parameters (with the exception of SOD activity) fell within their physiological ranges, indicating that the study participants represented a young and healthy male population. Hematological parameters differed between kickboxers and karate professionals. The low pro-oxidant-antioxidant balance and high SOD activity in wrestlers could be associated with the long-term impact of wrestling as a type of strenuous exercise.
Walter, Roland B.; Brasky, Theodore M.; Milano, Filippo; White, Emily
2011-01-01
Background Increasing evidence suggests that nutrients from fruits and vegetables have chemoprotective properties on various cancers including hematologic malignancies, but the effects of nutritional supplements are poorly examined. Methods Herein, we prospectively evaluated the association of vitamin, mineral, and specialty supplements with incident hematologic malignancies in 66,227 men and women aged 50 to 76 years from Washington State recruited from 2000–2002 to the VITamins And Lifestyle (VITAL) cohort study. Hematologic malignancies cases (n=588) were identified through December 2008 by linkage to the Surveillance, Epidemiology, and End Results (SEER) cancer registry. Hazard ratios (HRs) and 95% confidence intervals (95% CI) associated with supplement use were estimated with Cox proportional hazards models. Results After adjustment, high use of garlic supplements (≥4 days/week for ≥3 years; HR=0.55 [95% confidence interval: 0.34–0.87]; p=0.028 for trend) and ever use of grape seed supplements (HR=0.57 [0.37–0.88]) were inversely associated with hematologic malignancies in our models. In addition, high use (8–10 pill-years) of multivitamins was suggestive of an inverse association (HR)=0.80 [0.64–1.01]). In contrast, no associations were observed for the remaining supplements. Conclusions These data indicate that use of garlic and grape seed may be associated with reduced risk of hematologic malignancies. Impact This is the first cohort study to suggest a possible role of these supplements in the chemoprevention of hematologic malignancies. PMID:21803844
Experimental Theileria lestoquardi infection in sheep: Biochemical and hematological changes.
Yaghfoori, Saeed; Mohri, Mehrdad; Razmi, Gholamreza
2017-09-01
Malignant theileriosis (Theileria lestoquardi infection) is a hemoparasitic tick-borne disease that affects both wild and domestic small ruminants. The aim of this study was to evaluate biochemical and hematological characteristics of sheep after being experimentally infected by T. lestoquardi. T. lestoquardi infection was induced in seven Baluchi sheep of six-to-eight months old via experimentally-infected Hyalomma anatolicum adult ticks. Biochemical and hematological parameters were measured twice a week during the three weeks' post infection. Twenty-three biochemical analytes and seven hematological ones were measured. After three to four days infection, body temperature rose above 40 ° C. Maximum and minimum parasitaemia were 3.3% and 0.28%, respectively. Piroplasms and schizont were seen on average from days 7.2 and 4 post infection, respectively. The concentrations and activities of Alb, HDL, ALT, T3, T4, Ca, Fe, Mg, iP, WBC, RBC, PCV, Hb, Plt, neutrophil and lymphocytes significantly decreased (P≤0.05) during experimental infection. However, concentrations and activities of BT, GGT, Glu, BUN, Crea, FIB and Cu significantly increased (P≤0.05). There was no significant change in the serum amounts of Chol, LDL, TG, VLDL and Zn. The observed hypoalbuminemia and increase of FIB concentrations referred to pro-inflammatory cytokines production. Moreover, the raising of GGT activity indicates liver damage, cholestatic disorders or schizont infiltration. The disease stress and corticosteroids are suspected to cause the Glu concentration increase. The present study is aimed at improving the knowledge of malignant theileriosis. Copyright © 2017 Elsevier B.V. All rights reserved.
Automated homogeneous liposome immunoassay systems for anticonvulsant drugs.
Kubotsu, K; Goto, S; Fujita, M; Tuchiya, H; Kida, M; Takano, S; Matsuura, S; Sakurabayashi, I
1992-06-01
We developed automated homogeneous immunoassays, based on immunolysis of liposomes, for measuring phenytoin, phenobarbital, and carbamazepine from serum. Liposome lysis was detected spectrophotometrically from entrapped glucose-6-phosphate dehydrogenase activity. The procedure was fully automated on a routine automated clinical analyzer. Within-run, between-run, dilution, and recovery tests showed good accuracies and reproducibilities. Bilirubin, hemoglobin, triglycerides, and Intrafat did not affect assay results. The results obtained by liposome immunoassays for phenytoin, phenobarbital, and carbamazepine correlated well with those obtained by enzyme-multiplied immunoassay (Syva EMIT) kits (r = 0.995, 0.986, and 0.988, respectively) and fluorescence polarization immunoassay (Abbott TDx) kits (r = 0.990, 0.991, and 0.975, respectively). The proposed method should be useful for monitoring anticonvulsant drug concentrations in blood.
Nanopharmacology in translational hematology and oncology
Tomuleasa, Ciprian; Braicu, Cornelia; Irimie, Alexandra; Craciun, Lucian; Berindan-Neagoe, Ioana
2014-01-01
Nanoparticles have displayed considerable promise for safely delivering therapeutic agents with miscellaneous therapeutic properties. Current progress in nanotechnology has put forward, in the last few years, several therapeutic strategies that could be integrated into clinical use by using constructs for molecular diagnosis, disease detection, cytostatic drug delivery, and nanoscale immunotherapy. In the hope of bringing the concept of nanopharmacology toward a viable and feasible clinical reality in a cancer center, the present report attempts to present the grounds for the use of cell-free nanoscale structures for molecular therapy in experimental hematology and oncology. PMID:25092977
Mucorales-Specific T Cells in Patients with Hematologic Malignancies
Forghieri, Fabio; Candoni, Anna; Cesaro, Simone; Quadrelli, Chiara; Maertens, Johan; Rossi, Giulio; Morselli, Monica; Codeluppi, Mauro; Mussini, Cristina; Colaci, Elisabetta; Messerotti, Andrea; Paolini, Ambra; Maccaferri, Monica; Fantuzzi, Valeria; Del Giovane, Cinzia; Stefani, Alessandro; Morandi, Uliano; Maffei, Rossana; Marasca, Roberto; Narni, Franco; Fanin, Renato; Comoli, Patrizia; Romani, Luigina; Beauvais, Anne; Viale, Pier Luigi; Latgè, Jean Paul; Luppi, Mario
2016-01-01
Background Invasive mucormycosis (IM) is an emerging life-threatening fungal infection. It is difficult to obtain a definite diagnosis and to initiate timely intervention. Mucorales-specific T cells occur during the course of IM and are involved in the clearance of the infection. We have evaluated the feasibility of detecting Mucorales-specific T cells in hematological patients at risk for IM, and have correlated the detection of such cells with the clinical conditions of the patients. Methods and Findings By using an enzyme linked immunospot assay, the presence of Mucorales-specific T cells in peripheral blood (PB) samples has been investigated at three time points during high-dose chemotherapy for hematologic malignancies. Mucorales-specific T cells producing interferon-γ, interleukin-10 and interleukin-4 were analysed in order to detect a correlation between the immune response and the clinical picture. Twenty-one (10.3%) of 204 patients, accounting for 32 (5.3%) of 598 PB samples, tested positive for Mucorales-specific T cells. Two groups could be identified. Group 1, including 15 patients without signs or symptoms of invasive fungal diseases (IFD), showed a predominance of Mucorales-specific T cells producing interferon-gamma. Group 2 included 6 patients with a clinical picture consistent with invasive fungal disease (IFD): 2 cases of proven IM and 4 cases of possible IFD. The proven patients had significantly higher number of Mucorales-specific T cells producing interleukin-10 and interleukin-4 and higher rates of positive samples by using derived diagnostic cut-offs when compared with the 15 patients without IFD. Conclusions Mucorales-specific T cells can be detected and monitored in patients with hematologic malignancies at risk for IM. Mucorales-specific T cells polarized to the production of T helper type 2 cytokines are associated with proven IM and may be evaluated as a surrogate diagnostic marker for IM. PMID:26871570
Mucorales-Specific T Cells in Patients with Hematologic Malignancies.
Potenza, Leonardo; Vallerini, Daniela; Barozzi, Patrizia; Riva, Giovanni; Gilioli, Andrea; Forghieri, Fabio; Candoni, Anna; Cesaro, Simone; Quadrelli, Chiara; Maertens, Johan; Rossi, Giulio; Morselli, Monica; Codeluppi, Mauro; Mussini, Cristina; Colaci, Elisabetta; Messerotti, Andrea; Paolini, Ambra; Maccaferri, Monica; Fantuzzi, Valeria; Del Giovane, Cinzia; Stefani, Alessandro; Morandi, Uliano; Maffei, Rossana; Marasca, Roberto; Narni, Franco; Fanin, Renato; Comoli, Patrizia; Romani, Luigina; Beauvais, Anne; Viale, Pier Luigi; Latgè, Jean Paul; Lewis, Russell E; Luppi, Mario
2016-01-01
Invasive mucormycosis (IM) is an emerging life-threatening fungal infection. It is difficult to obtain a definite diagnosis and to initiate timely intervention. Mucorales-specific T cells occur during the course of IM and are involved in the clearance of the infection. We have evaluated the feasibility of detecting Mucorales-specific T cells in hematological patients at risk for IM, and have correlated the detection of such cells with the clinical conditions of the patients. By using an enzyme linked immunospot assay, the presence of Mucorales-specific T cells in peripheral blood (PB) samples has been investigated at three time points during high-dose chemotherapy for hematologic malignancies. Mucorales-specific T cells producing interferon-γ, interleukin-10 and interleukin-4 were analysed in order to detect a correlation between the immune response and the clinical picture. Twenty-one (10.3%) of 204 patients, accounting for 32 (5.3%) of 598 PB samples, tested positive for Mucorales-specific T cells. Two groups could be identified. Group 1, including 15 patients without signs or symptoms of invasive fungal diseases (IFD), showed a predominance of Mucorales-specific T cells producing interferon-gamma. Group 2 included 6 patients with a clinical picture consistent with invasive fungal disease (IFD): 2 cases of proven IM and 4 cases of possible IFD. The proven patients had significantly higher number of Mucorales-specific T cells producing interleukin-10 and interleukin-4 and higher rates of positive samples by using derived diagnostic cut-offs when compared with the 15 patients without IFD. Mucorales-specific T cells can be detected and monitored in patients with hematologic malignancies at risk for IM. Mucorales-specific T cells polarized to the production of T helper type 2 cytokines are associated with proven IM and may be evaluated as a surrogate diagnostic marker for IM.
Bailey, Abby M; Justice, Stephanie; Davis, George A; Weant, Kyle
2017-07-01
North American rattlesnake envenomations are known to produce coagulopathies and thrombocytopenia. However, the occurrence of delayed hematologic toxicity (less than seven days after envenomation) is poorly characterized in the medical literature. While the recurrence of hematologic derangements has been documented following envenomation, it is usually in the absence of clinically significant bleeding. Although commonly recommended to treat delayed coagulopathies, the effectiveness of crotalidae polyvalent immune Fab ovine (CroFab®) in managing this condition remains in question and warrants further investigation and exploration. We describe the case of a 19-year-old male who presented following rattlesnake envenomation at a church service who was treated with antivenin for 48 h and discharged home only to return four days later with profound thrombocytopenia, coagulopathy, and clinically significant bleeding. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Wiener, Earl L.
1988-01-01
The aims and methods of aircraft cockpit automation are reviewed from a human-factors perspective. Consideration is given to the mixed pilot reception of increased automation, government concern with the safety and reliability of highly automated aircraft, the formal definition of automation, and the ground-proximity warning system and accidents involving controlled flight into terrain. The factors motivating automation include technology availability; safety; economy, reliability, and maintenance; workload reduction and two-pilot certification; more accurate maneuvering and navigation; display flexibility; economy of cockpit space; and military requirements.
Computer-Aided Instruction in Automated Instrumentation.
ERIC Educational Resources Information Center
Stephenson, David T.
1986-01-01
Discusses functions of automated instrumentation systems, i.e., systems which combine electrical measuring instruments and a controlling computer to measure responses of a unit under test. The computer-assisted tutorial then described is programmed for use on such a system--a modern microwave spectrum analyzer--to introduce engineering students to…
Aminocaproic acid use in hospitalized patients with hematological malignancy: a case series.
Marshall, Ariela; Li, Ang; Drucker, Adrienne; Dzik, Walter
2016-09-01
The antifibrinolytic aminocaproic acid is widely used in surgical settings to prevent blood loss and decrease transfusion requirements, and small observational studies have suggested that aminocaproic acid may be useful in the setting of malignancy-related bleeding. At our institution, aminocaproic acid is sometimes prescribed to patients with hematological malignancy who experience refractory thrombocytopenia with or without bleeding. We performed a 5-year retrospective review of 54 adult patients with 13 types of hematological malignancy who received aminocaproic acid at our institution. Indications for use included 31 (57.4%) for refractory thrombocytopenia with bleeding, 16 (29.6%) for refractory thrombocytopenia without bleeding, and 7 (13%) for bleeding alone. Patients received both oral and intravenous formulations. Administered doses ranged broadly and median duration of use was 6 days. Three patients (5.7%) developed deep venous thrombosis but none of the thrombotic events were clearly related to administration of aminocaproic acid. We conclude that aminocaproic acid may be a relatively safe and cost-effective adjunct treatment in the setting of bleeding related to the diagnosis and treatment of hematological malignancy. Prospective trials as well as formalized protocols for the use of aminocaproic acid may be indicated. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
McFarland, Daniel C; Holland, Jimmie; Holcombe, Randall F
2015-07-01
The demand for hematologists and oncologists is not being met. We hypothesized that an inpatient hematology-oncology ward rotation would increase residents' interest. Potential reasons mitigating interest were explored and included differences in physician distress, empathy, resilience, and patient death experiences. Agreement with the statement "I am interested in pursuing a career/fellowship in hematology and oncology" was rated by residents before and after a hematology-oncology rotation, with 0 = not true at all, 1 = rarely true, 2 = sometimes true, 3 = often true, and 4 = true nearly all the time. House staff rotating on a hematology-oncology service from November 2013 to October 2014 also received questionnaires before and after their rotations containing the Connors-Davidson Resilience Scale, the Impact of Events Scale-Revised, the Interpersonal Reactivity Index, demographic information, and number of dying patients cared for and if a sense of meaning was derived from that experience. Fifty-six residents completed both before- and after-rotation questionnaires (response rate, 58%). The mean interest score was 1.43 initially and decreased to 1.24 after the rotation (P = .301). Female residents' mean score was 1.13 initially and dropped to 0.81 after the rotation (P = .04). Male residents' mean score was 1.71 initially and 1.81 after the rotation (P = .65). Decreased hematology-oncology interest correlated with decreased empathy; male interest decrease correlated with decreased resilience. An inpatient hematology-oncology ward rotation does not lead to increased interest and, for some residents, may lead to decreased interest in the field. Encouraging outpatient hematology-oncology rotations and the cultivation of resilience, empathy, and meaning regarding death experiences may increase resident interest. Copyright © 2015 by American Society of Clinical Oncology.
TBell: A mathematical tool for analyzing decision tables
NASA Technical Reports Server (NTRS)
Hoover, D. N.; Chen, Zewei
1994-01-01
This paper describes the development of mathematical theory and software to analyze specifications that are developed using decision tables. A decision table is a tabular format for specifying a complex set of rules that chooses one of a number of alternative actions. The report also describes a prototype tool, called TBell, that automates certain types of analysis.
Meyer, Antje; Salewsky, Bastian; Buchmann, Nikolaus; Steinhagen-Thiessen, Elisabeth; Demuth, Ilja
2016-01-01
The length of the chromosome ends, telomeres, is widely accepted as a biomarker of aging. However, the dynamic of the relationship between telomere length and hematopoietic parameters in the normal aging process, which is of particular interest with respect to age-related anemia, is not well understood. We have analyzed the relationship between relative leukocyte telomere length (rLTL) and several hematological parameters in the older group of the Berlin Aging Study II (BASE-II) participants. This paper also compares rLTL between both BASE-II age groups (22-37 and 60-83 years). Genomic DNA was extracted from peripheral blood leukocytes of BASE-II participants and used to determine rLTL by a quantitative PCR protocol. Standard methods were used to determine blood parameters, and the WHO criteria were used to identify anemic participants. Telomere length data were available for 444 younger participants (28.4 ± 3.1 years old; 52% women) and 1,460 older participants (68.2 ± 3.7 years old; 49.4% women). rLTL was significantly shorter in BASE-II participants of the older group (p = 3.7 × 10-12) and in women (p = 4.2 × 10-31). rLTL of older men exhibited a statistically significant, positive partial correlation with mean corpuscular hemoglobin (MCH; p = 0.012) and MCH concentration (p = 0.002). While these correlations were only observed in men, the rLTL of older women was negatively correlated with the number of thrombocytes (p = 0.015) in the same type of analysis. Among all older participants, 6% met the criteria to be categorized as 'anemic'; however, there was no association between anemia and rLTL. In the present study, we have detected isolated correlations between rLTL and hematological parameters; however, in all cases, rLTL explained only a small part of the variation of the analyzed parameters. In disagreement with some other studies showing similar data, we interpret the association between rLTL and some of the hematological parameters studied here to be
Flores-Santin, Josele; Rojas Antich, Maria; Tazawa, Hiroshi; Burggren, Warren W
2018-04-01
Hematology and its regulation in developing birds have been primarily investigated in response to relatively short-term environmental challenges in the embryo. Yet, whether any changes induced in the embryo persist into adulthood as a hematological form of "fetal programming" is unknown. We hypothesized that: 1) chronic as opposed to acute hypoxic incubation will alter hematological respiratory variables in embryos of bobwhite quail (Colinus virginianus), and 2) alterations first appearing in the embryo will persist into hatchlings through into adulthood. To test these hypotheses, we first developed an embryo-to-adult profile of normal hematological development by measuring hematocrit (Hct), red blood cell concentration ([RBC]), hemoglobin concentration ([Hb]), mean corpuscular volume, mean corpuscular hemoglobin and mean corpuscular hemoglobin concentration, as well plasma osmolality. Hct, [RBC] and [Hb] in normoxic-incubated birds (controls) steadily increased from ~22%, ~1.6 × 10 6 μL -1 and ~7 g% in day 12 embryos to almost double the values at maturity in adult birds. Both cohort and sex affected hematology of normoxic-incubated birds. A second population, incubated from day 0 (d0) in 15% O 2 , surprisingly revealed little or no significant difference from controls in hematology in embryos. In hatchlings and adults, hypoxic incubation caused no significant modification to any variables. Compared to major hematological effects caused by hypoxic incubation in chickens, the hematology of the bobwhite quail embryo appears to be minimally affected by hypoxic incubation, with very few effects induced during hypoxic incubation actually persisting into adulthood. Copyright © 2018 Elsevier Inc. All rights reserved.
López, Javier; Waters, Michael; Routh, Andrew; Rakotonanahary, Tsanta F; Woolaver, Lance; Thomasson, Ann; Holmes, Emma; Steinmetz, Hanspeter W
2017-03-01
Blood samples from 172 captive and 40 wild, healthy, juvenile and adult, ploughshare tortoises ( Astrochelys yniphora ) were analyzed to determine hematological and biochemical reference intervals. Hematological analytes included packed cell volume (PCV), white blood cell count (WBC), and WBC differential estimates. Biochemical analysis included total protein measured by photometry (TP) and by refractometry (TPr), albumin (ALB), creatine kinase (CK), aspartate aminotransferase (AST), glutamate dehydrogenase (GLDH), bile acids (BA), calcium (Ca), phosphorus (P), urea (UREA), and uric acid (UA). The jugular vein was identified as the preferred venipuncture site as subcarapacial vein venipuncture resulted in regular hemodilution. In due consideration of small sample sizes in some of the groups studied, adult tortoises had significantly higher plasma GLDH activity and TPr, TP, ALB, BA, and UREA concentrations and significantly lower AST activity and P concentration than juveniles. Captivity had a significant influence in some reference intervals, with captive adults presenting significantly higher WBC, and estimated counts of all white cell types as well as UREA and TPr than wild counterparts. Captive juveniles also showed significantly higher estimated monocyte and lower estimated eosinophil and basophil counts. Although these differences most likely reflect local environmental or dietary differences, without representing pathology or a deviation from the normal, they question the applicability of reference values from captive animals to wild animals and vice versa. Significant sex differences were only observed for PCV and UA. The reported reference intervals may serve as benchmarks for clinical assessment and conservation of this critically endangered species.
Platelet larger cell ratio (P-LCR) in patients with dyslipidemia.
Grotto, H Z W; Noronha, J F A
2004-10-01
We have described preliminary results of platelet larger cell ratio (P-LCR) analysis, provided by an automated hematology analyzer in patients with hypercholesterolemia and/or hypertriglyceremia. P-LCR values were significantly higher in patients (n = 41) than in control normal group (n = 20) (P < 0.0001). Larger platelets are more reactive and contribute to vasooclusive events in patients with dyslipidemia. P-LCR may be used as an indicator of risk factor for thromboembolic ischemic events.
Hematological and Biochemical Parameters in Elite Soccer Players During A Competitive Half Season
Anđelković, Marija; Baralić, Ivana; Đorđević, Brižita; Stevuljević, Jelena Kotur; Radivojević, Nenad; Dikić, Nenad; Škodrić, Sanja Radojević; Stojković, Mirjana
2015-01-01
Summary Background The purpose of the present study was to report and discuss the hematological and biochemical behavior of elite soccer players, in order to get more insight in the physiological characteristics of these sportsmen and to provide trainers and sports doctors with useful indicators. Methods Nineteen male soccer players volunteered to participate in this study. We followed the young elite soccer players during a competitive half season. Venous blood samples were collected between 9:00 and 10:00 a.m. after an overnight fast (10 h) at baseline, after 45 and 90 days and hematological and biochemical parameters were measured. Results Hemoglobin and hematocrit levels were significantly reduced over the observational period (p<0.05), but erythrocyte count and iron levels remained unchanged. Bilirubin and ferritin levels significantly increased in response to regular soccer training (p<0.05). We observed a significant decrease in muscle enzyme plasma activity during the 90 days study period. ANOVA analysis revealed a significant increase in the leukocyte and neutrophil counts (p<0.05), in parallel with a significant decrease in the lymphocyte count (p<0.05) after the observational period of 90 days. Conclusions Elite soccer players are characterized by significant changes in biochemical and hematological parameters over the half season, which are linked to training workload, as well as adaptation induced by the soccer training. Although the values of the measured parameters fell within the reference range, regular monitoring of the biochemical and hematological parameters is fundamental for the identification of a healthy status and related optimal performances by sport doctors and trainers and selection of a correct workload by trainers. PMID:28356856
Stevens, Jean-Luc R.; Elver, Marco; Bednar, James A.
2013-01-01
Lancet is a new, simulator-independent Python utility for succinctly specifying, launching, and collating results from large batches of interrelated computationally demanding program runs. This paper demonstrates how to combine Lancet with IPython Notebook to provide a flexible, lightweight, and agile workflow for fully reproducible scientific research. This informal and pragmatic approach uses IPython Notebook to capture the steps in a scientific computation as it is gradually automated and made ready for publication, without mandating the use of any separate application that can constrain scientific exploration and innovation. The resulting notebook concisely records each step involved in even very complex computational processes that led to a particular figure or numerical result, allowing the complete chain of events to be replicated automatically. Lancet was originally designed to help solve problems in computational neuroscience, such as analyzing the sensitivity of a complex simulation to various parameters, or collecting the results from multiple runs with different random starting points. However, because it is never possible to know in advance what tools might be required in future tasks, Lancet has been designed to be completely general, supporting any type of program as long as it can be launched as a process and can return output in the form of files. For instance, Lancet is also heavily used by one of the authors in a separate research group for launching batches of microprocessor simulations. This general design will allow Lancet to continue supporting a given research project even as the underlying approaches and tools change. PMID:24416014
Design of Malaria Diagnostic Criteria for the Sysmex XE-2100 Hematology Analyzer
Campuzano-Zuluaga, Germán; Álvarez-Sánchez, Gonzalo; Escobar-Gallo, Gloria Elcy; Valencia-Zuluaga, Luz Marina; Ríos-Orrego, Alexandra Marcela; Pabón-Vidal, Adriana; Miranda-Arboleda, Andrés Felipe; Blair-Trujillo, Silvia; Campuzano-Maya, Germán
2010-01-01
Thick film, the standard diagnostic procedure for malaria, is not always ordered promptly. A failsafe diagnostic strategy using an XE-2100 analyzer is proposed, and for this strategy, malaria diagnostic models for the XE-2100 were developed and tested for accuracy. Two hundred eighty-one samples were distributed into Plasmodium vivax, P. falciparum, and acute febrile syndrome groups for model construction. Model validation was performed using 60% of malaria cases and a composite control group of samples from AFS and healthy participants from endemic and non-endemic regions. For P. vivax, two observer-dependent models (accuracy = 95.3–96.9%), one non–observer-dependent model using built-in variables (accuracy = 94.7%), and one non–observer-dependent model using new and built-in variables (accuracy = 96.8%) were developed. For P. falciparum, two non–observer-dependent models (accuracies = 85% and 89%) were developed. These models could be used by health personnel or be integrated as a malaria alarm for the XE-2100 to prompt early malaria microscopic diagnosis. PMID:20207864
Pajor, A; Pozsonyi, T; Nékám, K; Bakos, L; Haraszti, L; Paulin, F
1998-02-22
The aim of the study was to determine the fetal and neonatal outcomes of pregnancies conceived during the inactive phase of systemic lupus erythematosus (SLE). Fetal and neonatal outcomes in 75 pregnancies of 33 patients with SLE were analyzed. In 19 patients (57.6%) the SLE also had hematological autoimmune presentations prior to gestation, such as anemia, thrombopenia, garnulocytopenia, and antiphospholipid antibody and/or lupus anticoagulant (APA). Out of 75 pregnancies, 19 elective terminations were carried out because the disease was active or for non-medical reasons. The adverse fetal outcomes of those 56 pregnancies which occurred during the inactive phase were compared with those of the control patients. In SLE, the rates of spontaneous abortions (46.4%) and newborns with low (< 2500 gr) birthweight (36.7%) were found to increase roughly three times that of the controls and the perinatal fetal loss (16.7%) also increased significantly as compared with the control group (28.5 per thousand). APA noted at any time before pregnancy increased the low birthweight rate (75%) six fold and the perinatal loss (33.3%) more than ten fold but did not affect the rate of spontaneous abortions. Any kind of hemocytopenias without APA, noted before pregnancy did not worsen the fetal outcome in SLE. Neonatal lupus was diagnosed in 2 out of the 30 newborns. Our results suggest that among the hematologic manifestations of SLE presenting before pregnancy, APA can predict the high risks of low birthweight and perinatal fetal loss as opposed to hemocytopenias.
Cierpicki, Tomasz; Grembecka, Jolanta
2015-01-01
Summary Over the past several years, there has been an increasing research effort focused on inhibition of protein-protein interactions (PPIs) to develop novel therapeutic approaches for cancer, including hematologic malignancies. These efforts have led to development of small molecule inhibitors of PPIs, some of which already advanced to the stage of clinical trials while others are at different stages of pre-clinical optimization, emphasizing PPIs as an emerging and attractive class of drug targets. Here, we review several examples of recently developed inhibitors of protein-protein interactions highly relevant to hematologic cancers. We address the existing skepticism about feasibility of targeting PPIs and emphasize potential therapeutic benefit from blocking PPIs in hematologic malignancies. We then use these examples to discuss the approaches for successful identification of PPI inhibitors and provide analysis of the protein-protein interfaces, with the goal to address ‘druggability’ of new PPIs relevant to hematology. We discuss lessons learned to improve the success of targeting new protein-protein interactions and evaluate prospects and limits of the research in this field. We conclude that not all PPIs are equally tractable for blocking by small molecules, and detailed analysis of PPI interfaces is critical for selection of those with the highest chance of success. Together, our analysis uncovers patterns that should help to advance drug discovery in hematologic malignancies by successful targeting of new protein-protein interactions. PMID:25510283
Seasonal influence on the hematological parameters in cultured Nile tilapia from southern Brazil.
Jerônimo, G T; Laffitte, L V; Speck, G M; Martins, M L
2011-08-01
This study evaluated seasonality in hematological parameters of Nile tilapia cultured in the state of Santa Catarina, southern Brazil. A total of 240 fish were examined during four seasons between April 2007 and March 2008 in three different fish farms. After being anesthetised in a benzocaine solution, blood samples were withdrawn into syringes containing a drop of 10% EDTA for hematological analysis. The results were compared between fish farms and seasons, which are well delimited in southern Brazil. In a traditional fish farm in Joinville in the summer, there was an increase in the percentage of hematocrit and in the red blood cell count. The highest values of total leukocytes were found in fish from fee-fishing in Blumenau in the autumn while the lowest values occurred in those from swine consorted system in Ituporanga in the summer. Thrombocytosis was observed in the autumn, and lymphocytosis was found in both the autumn and winter in tilapia from all fish farms investigated. Neutrophilia was only observed in winter and autumn in fish from Blumenau and Ituporanga. This work demonstrated the influence of seasonality and the handling characteristics of each fish farm on certain hematological parameters in Nile tilapia.
Kim, Jungkyu; Jensen, Erik C; Stockton, Amanda M; Mathies, Richard A
2013-08-20
A fully integrated multilayer microfluidic chemical analyzer for automated sample processing and labeling, as well as analysis using capillary zone electrophoresis is developed and characterized. Using lifting gate microfluidic control valve technology, a microfluidic automaton consisting of a two-dimensional microvalve cellular array is fabricated with soft lithography in a format that enables facile integration with a microfluidic capillary electrophoresis device. The programmable sample processor performs precise mixing, metering, and routing operations that can be combined to achieve automation of complex and diverse assay protocols. Sample labeling protocols for amino acid, aldehyde/ketone and carboxylic acid analysis are performed automatically followed by automated transfer and analysis by the integrated microfluidic capillary electrophoresis chip. Equivalent performance to off-chip sample processing is demonstrated for each compound class; the automated analysis resulted in a limit of detection of ~16 nM for amino acids. Our microfluidic automaton provides a fully automated, portable microfluidic analysis system capable of autonomous analysis of diverse compound classes in challenging environments.
Kurita, N; Frassoni, F; Chiba, S; Podestà, M
2015-06-01
As the history of the cord blood banking system has lengthened, the number of cord blood units (CBUs) cryopreserved for years has increased. The global expansion of cord blood banking resulted in active international exchange of CBUs. To determine whether long-term cryopreservation and international shipment of CBUs affect the quality of the units and outcome after transplantation, we retrospectively analyzed the quality of 95 CBUs and the hematologic recovery of 127 patients with hematological malignancy following single-unit cord blood transplantation. Of the 127 CBUs used to transplant, 42 units were cryopreserved for long periods (5-11.8 years), and 44 units were shipped from distant countries. We found that length of cryopreservation and origin of CBUs did not affect the ratio of viable total-nucleated cells after thawing. Also, neutrophil engraftment was not affected by long-term cryopreservation (> 5 years) or origin (from distant countries), (hazard ratio, 0.91 and 1.2; P=0.65 and 0.41; respectively). The number of CD34(+) cells before freezing (> 1.4 cells/kg recipient) was the only factor that enhanced neutrophil engraftment (hazard ratio, 1.8; P<0.01). This suggests that length of cryopreservation and origin need not be prioritized over the CD34(+) cell dose when selecting CBUs.
Jumping translocations in hematological malignancies: a cytogenetic study of five cases.
Manola, Kalliopi N; Georgakakos, Vasileios N; Stavropoulou, Chryssa; Spyridonidis, Alexandros; Angelopoulou, Maria K; Vlachadami, Ioanna; Katsigiannis, Andreas; Roussou, Paraskevi; Pantelias, Gabriel E; Sambani, Constantina
2008-12-01
Jumping translocations (JT) are rare cytogenetic aberrations in hematological malignancies that include unbalanced translocations involving a donor chromosome arm or chromosome segment that has fused to two or more different recipient chromosomes in different cell lines. We report five cases associated with different hematologic disorders and JT to contribute to the investigation of the origin, pathogenesis, and clinical significance of JT. These cases involve JT of 1q in a case of acute myeloblastic leukemia (AML)-M1, a case of Burkitt lymphoma, and a case of BCR/ABL-positive acute lymphoblastic leukemia, as well as a JT of 13q in a case of AML-M5, and a JT of 11q segment in a case of undifferentiated leukemia. To our knowledge, with regard to hematologic malignancies, this study presents the first case of JT associated with AML-M1, the first case of JT involving 13q as a donor chromosome, and the first report of JT involving a segment of 11q containing two copies of the MLL gene, jumping on to two recipient chromosomes in each cell line and resulting in six copies of the MLL gene. Our investigation suggests that JT may not contribute to the pathogenesis but rather to the progression of the disease, and it demonstrates that chromosome band 1q10 as a breakpoint of the donor chromosome 1q is also implicated in AML, not only in multiple myeloma as it has been known until now.
Hematologic reference values for clinically healthy captive golden conures (Guaruba guarouba).
Prioste, Fabíola Eloisa Setim; Zwarg, Ticiana; Teixeira, Rodrigo Hidalgo; Vanstreels, Ralph Eric Thijl; Rocha, Arnaldo; Matushima, Eliana Reiko
2012-12-01
Golden conures or ararajubas (Guaruba guarouba) are endangered parrots endemic to the Brazilian Amazon forest. Body mass, blood cell counts, and total plasma protein were determined for 70 clinically healthy golden conures captive at zoologic parks and private breeder facilities in Brazil. Hematologic results (mean +/- SD) were: Erythrocytes 3.6 +/- 0.5 x 10(6) cells/mm3, hemoglobin 12.8 +/- 1.4 g/dl, packed cell volume 46 +/- 3.8%, mean corpuscular volume 132 +/- 20 fl, mean corpuscular hemoglobin (MCH) 36 +/- 5.7 pg, mean corpuscular hemoglobin concentration (MCHC) 28 +/- 3.5%, thrombocytes 26.3 +/- 9.3 x 10(3) cells/mm3, leukocytes 11.9 +/- 4.5 x 10(3) cells/mm3, heterophils 6284 +/- 2715 cells/mm3, lymphocytes 5473 +/- 2408 cells/ mm3, monocytes 113 +/- 162 cells/mm3, eosinophils 10 +/- 42 cells/mm3, basophils 27 +/- 64 cells/mm3. Body mass was 254 +/- 24.9 g and total plasma protein (TPP) was 3.54 +/- 0.58 g/dl. No statistical differences were observed between genders within age groups. Differences between juveniles (J) and adults (A) were identified for TPP (J < A), MCH (J > A), and MCHC (J > A). These results provide reliable reference values for the clinical interpretation of hematologic results for the species. Hematology may be an important tool for population health investigations on free-ranging golden conure populations and will also be essential to survey the health of release candidates in future reintroduction programs.
Pretreatment Hematologic Findings as Novel Predictive Markers for Facial Palsy Prognosis.
Wasano, Koichiro; Kawasaki, Taiji; Yamamoto, Sayuri; Tomisato, Shuta; Shinden, Seiichi; Ishikawa, Toru; Minami, Shujiro; Wakabayashi, Takeshi; Ogawa, Kaoru
2016-10-01
To examine the relationship between prognosis of 2 different facial palsies and pretreatment hematologic laboratory values. Multicenter case series with chart review. Three tertiary care hospitals. We examined the clinical records of 468 facial palsy patients who were treated with an antiviral drug in combination with either oral or intravenous corticosteroids in participating hospitals between 2010 and 2014. Patients were divided into a Bell's palsy group or a Hunt's palsy group. We used the Yanagihara facial nerve grading system to grade the severity of facial palsy. "Recovery" from facial palsy was defined as achieving a Yanagihara score ≥36 points within 6 months of onset and having no accompanying facial contracture or synkinesis. We collected information about pretreatment hematologic findings, demographic data, and electrophysiologic test results of the Bell and Hunt group patients who recovered and those who did not. We then compared these data across the 2 palsy groups. In the Bell's palsy group, recovered and unrecovered patients differed significantly in age, sex, electroneuronography score, stapedial muscle reflex, neutrophil rate, lymphocyte rate, neutrophil-to-lymphocyte ratio, and initial Yanagihara score. In the Hunt's palsy group, recovered and unrecovered patients differed in age, electroneuronography score, stapedial muscle reflex, monocyte rate, platelet count, mean corpuscular volume, and initial Yanagihara score. Pretreatment hematologic findings, which reflect the severity of inflammation and bone marrow dysfunction caused by a virus infection, are useful for predicting the prognosis of facial palsy. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.
Hematological indicators of stress in longline-captured sharks.
Marshall, Heather; Field, Lyndsay; Afiadata, Achankeng; Sepulveda, Chugey; Skomal, Gregory; Bernal, Diego
2012-06-01
For many shark species, little information exists about the stress response to capture and release in commercial longline fisheries. Recent studies have used hematological profiling to assess the secondary stress response, but little is known about how, and to what degree, these indicators vary interspecifically. Moreover, there is little understanding of the extent to which the level of relative swimming activity (e.g., sluggish vs. active) or the general ecological classification (e.g., coastal vs. pelagic) correlates to the magnitude of the exercise-induced (capture-related) stress response. This study compared plasma electrolytes (Na(+), Cl(-), Mg(2+), Ca(2+), and K(+)), metabolites (glucose and lactate), blood hematocrit, and heat shock protein (Hsp70) levels between 11 species of longline-captured sharks (n=164). Statistical comparison of hematological parameters revealed species-specific differences in response to longline capture, as well as differences by ecological classification. Taken together, the blood properties of longline-captured sharks appear to be useful indicators of interspecific variation in the secondary stress response to capture, and may prove useful in the future for predicting survivorship of longline-captured sharks where new technologies (i.e., pop-up satellite tags) can verify post-release mortality. Copyright © 2012 Elsevier Inc. All rights reserved.
Nucleophosmin: a versatile molecule associated with hematological malignancies.
Naoe, Tomoki; Suzuki, Tatsuya; Kiyoi, Hitoshi; Urano, Takeshi
2006-10-01
Nucleophosmin (NPM) is a nucleolar phosphoprotein that plays multiple roles in ribosome assembly and transport, cytoplasmic-nuclear trafficking, centrosome duplication and regulation of p53. In hematological malignancies, the NPM1 gene is frequently involved in chromosomal translocation, mutation and deletion. The NPM1 gene on 5q35 is translocated with the anaplastic lymphoma kinase (ALK) gene in anaplastic large cell lymphoma with t(2;5). The MLF1 and RARA genes are fused with NPM1 in myelodysplastic syndrome and acute myeloid leukemia (AML) with t(3;5) and acute promyelocytic leukemia with t(5;17), respectively. In each fused protein, the N-terminal NPM portion is associated with oligomerization of a partner protein leading to altered signal transduction or transcription. Recently, mutations of exon 12 have been found in a significant proportion of de novo AML, especially in those with a normal karyotype. Mutant NPM is localized aberrantly in the cytoplasm, but the molecular mechanisms for leukemia remain to be studied. Studies of knock-out mice have revealed new aspects regarding NPM1 as a tumor-suppressor gene. This review focuses on the clinical significance of the NPM1 gene in hematological malignancies and newly discovered roles of NPM associated with oncogenesis.
[Standardization in laboratory hematology by participating in external quality assurance programs].
Nazor, Aida; Siftar, Zoran; Flegar-Mestrić, Zlata
2011-09-01
Since 1985, Department of Clinical Chemistry and Laboratory Medicine, Merkur University Hospital, Zagreb, has been participating in the International External Quality Assessment Scheme for Hematology (IEQAS-H) organized by the World Health Organization (WHO). Owing to very good results, in 1987 the Department received a certificate of participation in this control scheme. Department has been cooperating in the external quality assessment program in laboratory hematology which has been continuously performed in Croatia since 1986 by the Committee for External Quality Assessment Schemes under the auspices of the Croatian Society of Medical Biochemists and School of Pharmacy and Biochemistry, University of Zagreb. Nowadays, 186 medical biochemical laboratories are included in the National External Quality Assessment program, which is performed three times per year. Our Department has participated in the international projects of the European Committee for External Quality Assurance Programs in Laboratory Medicine (EQALM).
Hematological and biochemical features of postpartum fever in the heavy draft mare.
Aoki, Takahiro; Kimura, Yuki; Oya, Anna; Chiba, Akiko; Ishii, Mitsuo; Nambo, Yasuo
2016-01-01
Heavy draft mares potentially have a higher risk of suffering from postpartum fever (PF) than light breed mares. The purpose of this study was to compare hematological and biochemical features between clinically healthy mares (n=40) and PF-affected mares (n=16). Mares were classified as having PF when their rectal temperature rose to >38.5°C within 96 hr of foaling. The numbers of leukocytes, lymphocytes, and neutrophils and the serum magnesium level were significantly lower in PF-affected mares. The serum SAA and NEFA levels were significantly higher in PF-affected mares. Strong inflammation responses, fat mobilization associated with negative energy balance and possibly endotoxin participate in hematological and biochemical features of PF in heavy draft mares.
Winkelman, James W; Tanasijevic, Milenko J; Zahniser, David J
2017-08-01
- A novel automated slide-based approach to the complete blood count and white blood cell differential count is introduced. - To present proof of concept for an image-based approach to complete blood count, based on a new slide preparation technique. A preliminary data comparison with the current flow-based technology is shown. - A prototype instrument uses a proprietary method and technology to deposit a precise volume of undiluted peripheral whole blood in a monolayer onto a glass microscope slide so that every cell can be distinguished, counted, and imaged. The slide is stained, and then multispectral image analysis is used to measure the complete blood count parameters. Images from a 600-cell white blood cell differential count, as well as 5000 red blood cells and a variable number of platelets, that are present in 600 high-power fields are made available for a technologist to view on a computer screen. An initial comparison of the basic complete blood count parameters was performed, comparing 1857 specimens on both the new instrument and a flow-based hematology analyzer. - Excellent correlations were obtained between the prototype instrument and a flow-based system. The primary parameters of white blood cell, red blood cell, and platelet counts resulted in correlation coefficients (r) of 0.99, 0.99, and 0.98, respectively. Other indices included hemoglobin (r = 0.99), hematocrit (r = 0.99), mean cellular volume (r = 0.90), mean corpuscular hemoglobin (r = 0.97), and mean platelet volume (r = 0.87). For the automated white blood cell differential counts, r values were calculated for neutrophils (r = 0.98), lymphocytes (r = 0.97), monocytes (r = 0.76), eosinophils (r = 0.96), and basophils (r = 0.63). - Quantitative results for components of the complete blood count and automated white blood cell differential count can be developed by image analysis of a monolayer preparation of a known volume of peripheral blood.
Urgent Chemotherapy in Sepsis-Like Shock Related to Hematologic Malignancies.
Cherruault, Marlène; Le Goff, Marielle; Tamburini, Jérôme; Pène, Frédéric
2018-05-01
Hematologic malignancies may result in multiple organ involvement including pulmonary and renal dysfunctions, and the less common acute circulatory failure. We herein addressed the outcome of patients with sepsis-like shock related to aggressive hematologic malignancies. A 10-year (2007-2016) monocenter retrospective study. A medical ICU in a tertiary care center. Patients with circulatory shock requiring vasopressors and who subsequently received chemotherapy. Shock was presumably related to the underlying malignancy after ruling out an ongoing or new-onset infectious process. The extent and time course of organ failures was assessed by a modified Sequential Organ Failure Assessment score devoid of the platelet component. None. Seventeen patients were included, including 13 with non-Hodgkin lymphoma, two with hyperleukocytic acute myeloid leukemia, and two with "Human Herpes virus 8"-associated multicentric Castleman's disease. The following associated conditions prompted urgent administration of chemotherapy: tumor lysis syndrome (n = 10), hemophagocytic lymphohistiocytosis (n = 3), compressive bulky tumor (n = 3), pulmonary involvement (n = 3), and disseminated intravascular coagulation (n = 1). Following the initiation of chemotherapy, a number of patients died rapidly from untractable multiple organ failure. In contrast, chemotherapy led to a fast and dramatic improvement in organ failures in early survivors, as shown by the decrease in the modified Sequential Organ Failure Assessment score. However, the overall outcome was poor since only four and three patients could be discharged alive from the ICU and the hospital, and three and two patients remained alive at 6 months and 1 year. Multiple organ dysfunction syndrome related to hematologic malignancies is associated with a dismal outcome. A chemotherapy trial may provide a fast prognostic assessment of the reversibility of organ failure.
Pereira, Lucas Cardoso; Barros, Marilia
2016-06-01
Basal thermal values of captive adult black tufted-ear marmosets (Callithrix penicillata) in a thermoneutral environment were measured via different methods, along with body weight and hematological parameters. Body temperatures were recorded with rectal (RC), subcutaneous (SC) microchip transponder and infrared (left and right) tympanic membrane (TM) thermometries. Thermal values were correlated with body mass and some hematological data. Similar RC and SC temperatures were observed, these being significantly higher than the left and right TM values. SC temperature was positively correlated and in close agreement with RC measurements. Although body temperatures were not influenced by gender, capture time, or body weight, they were correlated with hematological parameters. Thus, body temperatures in this species seem to reflect some of the characteristics of the assessments' location, with SC microchip transponders being a less invasive method to assess body temperature in these small-bodied non-human primates. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Summary of astronaut inputs on automation and robotics for Space Station Freedom
NASA Technical Reports Server (NTRS)
Weeks, David J.
1990-01-01
Astronauts and payload specialists present specific recommendations in the form of an overview that relate to the use of automation and robotics on the Space Station Freedom. The inputs are based on on-orbit operations experience, time requirements for crews, and similar crew-specific knowledge that address the impacts of automation and robotics on productivity. Interview techniques and specific questionnaire results are listed, and the majority of the responses indicate that incorporating automation and robotics to some extent and with human backup can improve productivity. Specific support is found for the use of advanced automation and EVA robotics on the Space Station Freedom and for the use of advanced automation on ground-based stations. Ground-based control of in-flight robotics is required, and Space Station activities and crew tasks should be analyzed to assess the systems engineering approach for incorporating automation and robotics.
NASA Technical Reports Server (NTRS)
Shively, Jay
2017-01-01
A significant level of debate and confusion has surrounded the meaning of the terms autonomy and automation. Automation is a multi-dimensional concept, and we propose that Remotely Piloted Aircraft Systems (RPAS) automation should be described with reference to the specific system and task that has been automated, the context in which the automation functions, and other relevant dimensions. In this paper, we present definitions of automation, pilot in the loop, pilot on the loop and pilot out of the loop. We further propose that in future, the International Civil Aviation Organization (ICAO) RPAS Panel avoids the use of the terms autonomy and autonomous when referring to automated systems on board RPA. Work Group 7 proposes to develop, in consultation with other workgroups, a taxonomy of Levels of Automation for RPAS.
Jegede, Feyisayo Ebenezer; Oyeyi, Tinuade Ibijoke; Abdulrahman, Surajudeen Abiola; Mbah, Henry Akwen; Badru, Titilope; Agbakwuru, Chinedu; Adedokun, Oluwasanmi
2017-01-01
Human immunodeficiency virus (HIV) and malaria co-infection may present worse health outcomes in the tropics. Information on HIV/malaria co-infection effect on immune-hematological profiles is critical for patient care and there is a paucity of such data in Nigeria. To evaluate immune-hematological profiles among HIV infected patients compared to HIV/malaria co-infected for ART management improvement. This was a cross sectional study conducted at Infectious Disease Hospital, Kano. A total of 761 consenting adults attending ART clinic were randomly selected and recruited between June and December 2015. Participants' characteristics and clinical details including two previous CD4 counts were collected. Venous blood sample (4ml) was collected in EDTA tube for malaria parasite diagnosis by rapid test and confirmed with microscopy. Hematological profiles were analyzed by Sysmex XP-300 and CD4 count by Cyflow cytometry. Data was analyzed with SPSS 22.0 using Chi-Square test for association between HIV/malaria parasites co-infection with age groups, gender, ART, cotrimoxazole and usage of treated bed nets. Mean hematological profiles by HIV/malaria co-infection and HIV only were compared using independent t-test and mean CD4 count tested by mixed design repeated measures ANOVA. Statistical significant difference at probability of <0.05 was considered for all variables. Of the 761 HIV infected, 64% were females, with a mean age of ± (SD) 37.30 (10.4) years. Prevalence of HIV/malaria co-infection was 27.7% with Plasmodium falciparum specie accounting for 99.1%. No statistical significant difference was observed between HIV/malaria co-infection in association to age (p = 0.498) and gender (p = 0.789). A significantly (p = 0.026) higher prevalence (35.2%) of co-infection was observed among non-ART patients compared to (26%) ART patients. Prevalence of co-infection was significantly lower (20.0%) among cotrimoxazole users compared to those not on cotrimoxazole (37%). The same
Galagarza, Oscar A; Kuhn, David D; Smith, Stephen A; Hrubec, Terry C
2017-09-01
Striped catfish (Pangasius hypophthalmus) is a valuable aquaculture fish species produced primarily in Southeast Asia. In the United States, it is bred as an ornamental species. Striped catfish has high productivity and great demand in numerous countries around the world, yet little is known about its normal physiology. The objective of this study was to establish hematologic and blood chemistry RIs for healthy juvenile Striped catfish. Blood samples were collected from 70 Striped catfish raised in recirculating aquaculture systems. Whole blood and plasma samples were analyzed for multiple hematologic and chemistry variables using standard techniques. The RIs for hematology were as follows: PCV 23.5-35.9%, MCV 106.3-156.6 fL, RBC count 1.79-2.75 × 10 6 cells/μL, thrombocytes 26,318-73,333 cells/μL, total WBC count 36,294-94,286 cells/μL, total lymphocytes 18,997-59,998 cells/μL, small lymphocytes 13,763-51,490 cells/μL, large lymphocytes 715-21,200 cells/μL, granulocytes 4504-18,291 cells/μL, and monocytes 0-7549 cells/μL. Plasma chemistry RIs were the following: ALP 32.7-74.6 U/L, AST 20.3-1235.8 U/L, sodium 135.2-147.7 mmol/L, potassium 3.3-5.0 mmol/L, chloride 120.1-133.6 mmol/L, calcium 2.7-3.6 mmol/L, magnesium 0.9-1.3 mmol/L, phosphorous 1.4-2.7 mmol/L, glucose 4.6-7.6 mmol/L, cholesterol 2.8-5.3 mmol/L, total protein 30-42 g/L, albumin 7-11 g/L, globulin 22-32 g/L, albumin:globulin ratio 0.27-0.37, creatinine 0-8 μmol/L, and osmolality 251.8-327.9 mOsm/kg. Reference intervals reported here can help veterinarians and fish health specialists monitor the health status of Striped catfish under recirculating aquaculture conditions for research, exhibition, and production purposes. © 2017 American Society for Veterinary Clinical Pathology.
Emergencies in Hematology and Oncology.
Halfdanarson, Thorvardur R; Hogan, William J; Madsen, Bo E
2017-04-01
The development of medical emergencies related to the underlying disease or as a result of complications of therapy are common in patients with hematologic or solid tumors. These oncological emergencies can occur as an initial presentation or in a patient with an established diagnosis and are encountered in all medical care settings, ranging from primary care to the emergency department and various subspecialty environments. Therefore, it is critically important that all physicians have a working knowledge of the potential oncological emergencies that may present in their practice and how to provide the most effective care without delay. This article reviews the most common oncological emergencies and provides practical guidance for initial management of these patients. Copyright © 2017 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Ross, D W; Bishop, C; Henderson, A; Kaplow, L
1990-01-01
We adapted previously published methods for nonspecific esterase and alkaline phosphatase staining of white blood cells in suspension for use on a Technicon H-1 hematology analyzer. The objective was to develop a semiautomated method using whole blood that could be employed on a large scale for hematology laboratory applications, including toxicology studies, measurement of neutrophil left shift, and cytochemical classification of myeloid leukemias. The nonspecific esterase method uses the pararosaniline stain, generating the unstable substrate from two stable precursors. Whole blood is added to the substrate plus dye mix. Next, acid lysis and fixation steps destroy red cells and stabilize the monocyte staining. The alkaline phosphatase stain employs a stable naphthyl phosphate substrate and fast blue B coupling dye. The red cells are lysed with a pH 10.3 propanediol buffer, and the white blood cells are then stabilized with formalin fixation. For both methods the staining is performed off-line, and the sample is then diluted with propanediol to match the refractive index of the sheath on the H-1 analyzer, before aspiration into the direct cytometry port. A cytogram of scattered versus absorbed light is obtained. The number of cells staining and the intensity of the stain can be quantified from the cytogram.
Decision making in critically ill patients with hematologic malignancy.
Crawford, S. W.
1991-01-01
Hematologic neoplasms that were previously considered fatal are now potentially curable with techniques such as bone marrow transplantation. Such therapies also carry significant morbidity and mortality. With the increasing application of these therapies, a growing number of physicians are using medical decision making regarding critical care for these patients. The process by which ethical decisions are reached for these critically ill patients may be baffling because of several factors: rapidly evolving treatments, uncertain probabilities of the cure of the malignant disorder, the relatively young age of many of these patients, and the poor prognosis with critical illness. I discuss a process to reach acceptable decisions, providing a case example of the application of the process. This process is derived from the ethical principles that drive decision making in general medicine and attempts to maximize patients' autonomy. It involves a consideration of accurate information regarding the disease process and the prognosis, a clear delineation of the goals of the medical care, and communication with patients. Appropriate, ethical, and consistent decisions regarding the critical care of patients with hematologic malignancy can be reached when these considerations are addressed. PMID:1815387
Trace-Level Automated Mercury Speciation Analysis
Taylor, Vivien F.; Carter, Annie; Davies, Colin; Jackson, Brian P.
2011-01-01
An automated system for methyl Hg analysis by purge and trap gas chromatography (GC) was evaluated, with comparison of several different instrument configurations including chromatography columns (packed column or capillary), detector (atomic fluorescence, AFS, or inductively coupled plasma mass spectrometry, ICP-MS, using quadrupole and sector field ICP- MS instruments). Method detection limits (MDL) of 0.042 pg and 0.030 pg for CH3Hg+ were achieved with the automated Hg analysis system configured with AFS and ICPMS detection, respectively. Capillary GC with temperature programming was effective in improving resolution and decreasing retention times of heavier Hg species (in this case C3H7Hg+) although carryover between samples was increased. With capillary GC, the MDL for CH3Hg+ was 0.25 pg for AFS detection and 0.060 pg for ICP-MS detection. The automated system was demonstrated to have high throughput (72 samples analyzed in 8 hours) requiring considerably less analyst time than the manual method for methyl mercury analysis described in EPA 1630. PMID:21572543
Kudella, Patrick Wolfgang; Moll, Kirsten; Wahlgren, Mats; Wixforth, Achim; Westerhausen, Christoph
2016-04-18
Rosetting is associated with severe malaria and a primary cause of death in Plasmodium falciparum infections. Detailed understanding of this adhesive phenomenon may enable the development of new therapies interfering with rosette formation. For this, it is crucial to determine parameters such as rosetting and parasitaemia of laboratory strains or patient isolates, a bottleneck in malaria research due to the time consuming and error prone manual analysis of specimens. Here, the automated, free, stand-alone analysis software automated rosetting analyzer for micrographs (ARAM) to determine rosetting rate, rosette size distribution as well as parasitaemia with a convenient graphical user interface is presented. Automated rosetting analyzer for micrographs is an executable with two operation modes for automated identification of objects on images. The default mode detects red blood cells and fluorescently labelled parasitized red blood cells by combining an intensity-gradient with a threshold filter. The second mode determines object location and size distribution from a single contrast method. The obtained results are compared with standardized manual analysis. Automated rosetting analyzer for micrographs calculates statistical confidence probabilities for rosetting rate and parasitaemia. Automated rosetting analyzer for micrographs analyses 25 cell objects per second reliably delivering identical results compared to manual analysis. For the first time rosette size distribution is determined in a precise and quantitative manner employing ARAM in combination with established inhibition tests. Additionally ARAM measures the essential observables parasitaemia, rosetting rate and size as well as location of all detected objects and provides confidence intervals for the determined observables. No other existing software solution offers this range of function. The second, non-malaria specific, analysis mode of ARAM offers the functionality to detect arbitrary objects
McGann, Patrick T.; Tyburski, Erika A.; de Oliveira, Vysolela; Santos, Brigida; Ware, Russell E.; Lam, Wilbur A.
2016-01-01
Severe anemia is an important cause of morbidity and mortality among children in resource-poor settings, but laboratory diagnostics are often limited in these locations. To address this need, we developed a simple, inexpensive, and color-based point-of-care (POC) assay to detect severe anemia. The purpose of this study was to evaluate the accuracy of this novel POC assay to detect moderate and severe anemia in a limited-resource setting. The study was a cross-sectional study conducted on children with sickle cell anemia in Luanda, Angola. The hemoglobin concentrations obtained by the POC assay were compared to reference values measured by a calibrated automated hematology analyzer. A total of 86 samples were analyzed (mean hemoglobin concentration 6.6 g/dL). There was a strong correlation between the hemoglobin concentrations obtained by the POC assay and reference values obtained from an automated hematology analyzer (r=0.88, P<0.0001). The POC assay demonstrated excellent reproducibility (r=0.93, P<0.0001) and the reagents appeared to be durable in a tropical setting (r=0.93, P<0.0001). For the detection of severe anemia that may require blood transfusion (hemoglobin <5 g/dL), the POC assay had sensitivity of 88.9% and specificity of 98.7%. These data demonstrate that an inexpensive (<$0.25 USD) POC assay accurately estimates low hemoglobin concentrations and has the potential to become a transformational diagnostic tool for severe anemia in limited-resource settings. PMID:26317494
Yan, Kevin; Ramirez, Ezequiel; Xie, Xian-Jin; Gu, Xuejun; Xi, Yin; Albuquerque, Kevin
The purpose of this study was to determine factors predictive for severe hematologic toxicity (HT) in cervical cancer patients with para-aortic lymph node metastasis treated with concurrent cisplatin chemoradiation to an extended field (EFCRT). Thirty-eight patients with cervical cancer and para-aortic lymph node metastasis who underwent EFCRT were analyzed. Active bone marrow was defined as the region within irradiated total bone marrow (BM TOT ) with a standard uptake value on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography greater than the mean standard uptake value for BM TOT . Serial weekly blood counts from the beginning to the end of radiation treatment were evaluated for HT using Common Terminology Criteria for Adverse Events, version 4.0. Nineteen patients had grade 3 or higher hematologic toxicity (HT3+), not including lymphocyte toxicity. Obese patients (n = 12) were less likely to get HT3+ (P = .03) despite getting equivalent doses of chemotherapy. Volumes of BM TOT and active bone marrow receiving doses of 20, 30, and 45 Gy and body mass index significantly predicted HT3+. Patients who had HT3+ had prolonged treatment time (62 vs 53 days, P < .001). For patients receiving EFCRT, bone marrow irradiation parameters and patient body mass index were associated with HT3+. A simplified nomogram has been created to predict HT3+ in these patients, allowing the potential to explore bone marrow-sparing delivery techniques. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
SHARP: Automated monitoring of spacecraft health and status
NASA Technical Reports Server (NTRS)
Atkinson, David J.; James, Mark L.; Martin, R. Gaius
1991-01-01
Briefly discussed here are the spacecraft and ground systems monitoring process at the Jet Propulsion Laboratory (JPL). Some of the difficulties associated with the existing technology used in mission operations are highlighted. A new automated system based on artificial intelligence technology is described which seeks to overcome many of these limitations. The system, called the Spacecraft Health Automated Reasoning Prototype (SHARP), is designed to automate health and status analysis for multi-mission spacecraft and ground data systems operations. The system has proved to be effective for detecting and analyzing potential spacecraft and ground systems problems by performing real-time analysis of spacecraft and ground data systems engineering telemetry. Telecommunications link analysis of the Voyager 2 spacecraft was the initial focus for evaluation of the system in real-time operations during the Voyager spacecraft encounter with Neptune in August 1989.
SHARP - Automated monitoring of spacecraft health and status
NASA Technical Reports Server (NTRS)
Atkinson, David J.; James, Mark L.; Martin, R. G.
1990-01-01
Briefly discussed here are the spacecraft and ground systems monitoring process at the Jet Propulsion Laboratory (JPL). Some of the difficulties associated with the existing technology used in mission operations are highlighted. A new automated system based on artificial intelligence technology is described which seeks to overcome many of these limitations. The system, called the Spacecraft Health Automated Reasoning Prototype (SHARP), is designed to automate health and status analysis for multi-mission spacecraft and ground data systems operations. The system has proved to be effective for detecting and analyzing potential spacecraft and ground systems problems by performing real-time analysis of spacecraft and ground data systems engineering telemetry. Telecommunications link analysis of the Voyager 2 spacecraft was the initial focus for evaluation of the system in real-time operations during the Voyager spacecraft encounter with Neptune in August 1989.
Diagnostic Application of Absolute Neutron Activation Analysis in Hematology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zamboni, C.B.; Oliveira, L.C.; Dalaqua, L. Jr.
2004-10-03
The Absolute Neutron Activation Analysis (ANAA) technique was used to determine element concentrations of Cl and Na in blood of healthy group (male and female blood donators), select from Blood Banks at Sao Paulo city, to provide information which can help in diagnosis of patients. This study permitted to perform a discussion about the advantages and limitations of using this nuclear methodology in hematological examinations.
Perri, Amanda M.; O’Sullivan, Terri L.; Harding, John C.S.; Wood, R. Darren; Friendship, Robert M.
2017-01-01
The evaluation of pig hematology and biochemistry parameters is rarely done largely due to the costs associated with laboratory testing and labor, and the limited availability of reference intervals needed for interpretation. Within-herd and between-herd biological variation of these values also make it difficult to establish reference intervals. Regardless, baseline reference intervals are important to aid veterinarians in the interpretation of blood parameters for the diagnosis and treatment of diseased swine. The objective of this research was to provide reference intervals for hematology and biochemistry parameters of 3-week-old commercial nursing piglets in Ontario. A total of 1032 pigs lacking clinical signs of disease from 20 swine farms were sampled for hematology and iron panel evaluation, with biochemistry analysis performed on a subset of 189 randomly selected pigs. The 95% reference interval, mean, median, range, and 90% confidence intervals were calculated for each parameter. PMID:28373729
Gedik, Habip; Şimşek, Funda; Kantürk, Arzu; Yildirmak, Taner; Arica, Deniz; Aydin, Demet; Demirel, Naciye; Yokuş, Osman
2014-01-01
Background The primary objective of this study was to report the incidence of bloodstream infections (BSIs) and clinically or microbiologically proven bacterial or fungal BSIs during neutropenic episodes in patients with hematological malignancies. Methods In this retrospective observational study, all patients in the hematology department older than 14 years who developed febrile neutropenia during chemotherapy for hematological cancers were evaluated. Patients were included if they had experienced at least one neutropenic episode between November 2010 and November 2012 due to chemotherapy in the hematology ward. Results During 282 febrile episodes in 126 patients, 66 (23%) episodes of bacteremia and 24 (8%) episodes of fungemia were recorded in 48 (38%) and 18 (14%) patients, respectively. Gram-negative bacteria caused 74% (n=49) of all bacteremic episodes. Carbapenem-resistant Gram-negative bacteria (n=6) caused 12% and 9% of Gram-negative bacteremia episodes and all bacteremia episodes, respectively. Carbapenem-resistant Gram-negative bacteria included Acinetobacter baumannii (n=4), Pseudomonas aeruginosa (n=1), and Serratia marcescens (n=1). Culture-proven invasive fungal infection occurred in 24 episodes in 18 cases during the study period, with 15 episodes in ten cases occurring in the first study year and nine episodes in eight cases in the second study year. In 13 of 18 cases (72%) with bloodstream yeast infections, previous azole exposure was recorded. Candida parapsilosis, C. glabrata, and C. albicans isolates were resistant to voriconazole and fluconazole. Conclusion BSIs that occur during febrile neutropenic episodes in hematology patients due to Gram-negative bacteria should be treated initially with non-carbapenem-based antipseudomonal therapy taking into consideration antimicrobial stewardship. Non-azole antifungal drugs, including caspofungin and liposomal amphotericin B, should be preferred as empirical antifungal therapy in the events of possible
Extracellular Vesicles in Hematological Malignancies: From Biology to Therapy
Caivano, Antonella; La Rocca, Francesco; Laurenzana, Ilaria; Trino, Stefania; De Luca, Luciana; Lamorte, Daniela; Del Vecchio, Luigi; Musto, Pellegrino
2017-01-01
Extracellular vesicles (EVs) are a heterogeneous group of particles, between 15 nanometers and 10 microns in diameter, released by almost all cell types in physiological and pathological conditions, including tumors. EVs have recently emerged as particularly interesting informative vehicles, so that they could be considered a true “cell biopsy”. Indeed, EV cargo, including proteins, lipids, and nucleic acids, generally reflects the nature and status of the origin cells. In some cases, EVs are enriched of peculiar molecular cargo, thus suggesting at least a degree of specific cellular packaging. EVs are identified as important and critical players in intercellular communications in short and long distance interplays. Here, we examine the physiological role of EVs and their activity in cross-talk between bone marrow microenvironment and neoplastic cells in hematological malignancies (HMs). In these diseases, HM EVs can modify tumor and bone marrow microenvironment, making the latter “stronger” in supporting malignancy, inducing drug resistance, and suppressing the immune system. Moreover, EVs are abundant in biologic fluids and protect their molecular cargo against degradation. For these and other “natural” characteristics, EVs could be potential biomarkers in a context of HM liquid biopsy and therapeutic tools. These aspects will be also analyzed in this review. PMID:28574430
78 FR 69324 - Revised Medical Criteria for Evaluating Hematological Disorders
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-19
.... ADDRESSES: You may submit comments by one of three methods--Internet, fax, or mail. Do not submit the same comments multiple times or by more than one method. Regardless of which method you choose, please state... hematological disorder. In proposed sections 7.00B1 and B2, we provide two methods for establishing the...
ORIGAMI Automator Primer. Automated ORIGEN Source Terms and Spent Fuel Storage Pool Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wieselquist, William A.; Thompson, Adam B.; Bowman, Stephen M.
2016-04-01
Source terms and spent nuclear fuel (SNF) storage pool decay heat load analyses for operating nuclear power plants require a large number of Oak Ridge Isotope Generation and Depletion (ORIGEN) calculations. SNF source term calculations also require a significant amount of bookkeeping to track quantities such as core and assembly operating histories, spent fuel pool (SFP) residence times, heavy metal masses, and enrichments. The ORIGEN Assembly Isotopics (ORIGAMI) module in the SCALE code system provides a simple scheme for entering these data. However, given the large scope of the analysis, extensive scripting is necessary to convert formats and process datamore » to create thousands of ORIGAMI input files (one per assembly) and to process the results into formats readily usable by follow-on analysis tools. This primer describes a project within the SCALE Fulcrum graphical user interface (GUI) called ORIGAMI Automator that was developed to automate the scripting and bookkeeping in large-scale source term analyses. The ORIGAMI Automator enables the analyst to (1) easily create, view, and edit the reactor site and assembly information, (2) automatically create and run ORIGAMI inputs, and (3) analyze the results from ORIGAMI. ORIGAMI Automator uses the standard ORIGEN binary concentrations files produced by ORIGAMI, with concentrations available at all time points in each assembly’s life. The GUI plots results such as mass, concentration, activity, and decay heat using a powerful new ORIGEN Post-Processing Utility for SCALE (OPUS) GUI component. This document includes a description and user guide for the GUI, a step-by-step tutorial for a simplified scenario, and appendices that document the file structures used.« less
Salakij, Chaleow; Salakij, Jarernsak; Apibal, Suntaree; Narkkong, Nual-Anong; Chanhome, Lawan; Rochanapat, Nirachara
2002-01-01
King cobras (Ophiophagus hannah) have been captive-bred at Queen Saovabha Memorial Institute since 1996 to supply venom for antivenom production. Hematologic tests would be useful for evaluating the health of the snakes, however, basic hematologic data and morphology have not been described for this species. The purpose of this study was to determine basic hematologic values and evaluate light microscopic, cytochemical, and electron microscopic characteristics of king cobra blood cells. Blood samples from 13 wild-caught and 15 captive-bred king cobras were collected into EDTA from the ventral caudal vein. A CBC was done using standard methods. Significant differences between groups were determined using t-tests. Cytochemical stains (periodic acid-Schiff [PAS], Sudan black B [SBB], alpha-naphthyl acetate esterase [ANAE], acid phosphatase [AcP], and beta-glucuronidase [beta-glu]), and scanning and transmission electron microscopy were done using standard techniques. Eighteen snakes (64.3%) were positive for Hepatozoon infection. Hepatozoon organisms were detected nearly twice as frequently in wild-caught (11/13) as in captive-bred (7/15) snakes. Total WBC, azurophil, and lymphocyte counts were higher and fibrinogen concentration was lower in Hepatozoon-positive snakes. Captive-bred snakes had higher RBC values, lower azurophil, heterophil, and punctate reticulocyte percentages, and higher lymphocyte numbers compared with wild-caught snakes. Lymphocytes were the most commonly observed WBCs, and stained positive with PAS, ANAE, AcP, and beta-glu. Azurophil granules stained positive with SBB, PAS, and ANAE. Heterophils were the largest WBCs; their granules stained with SBB, ANAE, and beta-glu. Basophil granules stained with PAS, SBB, ANAE, and beta-glu. Thrombocytes were strongly positive with PAS. Transmission electron microscopic examination revealed organelles within all WBCs except eosinophils and revealed the gamonts of Hepatozoon sp in RBCs and azurophils. These
NASA Technical Reports Server (NTRS)
Strekalov, Dmitry V.
2012-01-01
Ring Image Analyzer software analyzes images to recognize elliptical patterns. It determines the ellipse parameters (axes ratio, centroid coordinate, tilt angle). The program attempts to recognize elliptical fringes (e.g., Newton Rings) on a photograph and determine their centroid position, the short-to-long-axis ratio, and the angle of rotation of the long axis relative to the horizontal direction on the photograph. These capabilities are important in interferometric imaging and control of surfaces. In particular, this program has been developed and applied for determining the rim shape of precision-machined optical whispering gallery mode resonators. The program relies on a unique image recognition algorithm aimed at recognizing elliptical shapes, but can be easily adapted to other geometric shapes. It is robust against non-elliptical details of the image and against noise. Interferometric analysis of precision-machined surfaces remains an important technological instrument in hardware development and quality analysis. This software automates and increases the accuracy of this technique. The software has been developed for the needs of an R&TD-funded project and has become an important asset for the future research proposal to NASA as well as other agencies.
Milijašević, B; Stefanović, D; Lalić-Popović, M; Tomić, Z; Kolarović, J; Lalošević, D; Mikov, M
2014-11-01
Treatment of advanced soft tissue sarcoma usually includes dacarbazine (DTIC), an alkylating agent that methylates DNA and is active during all phases of the cell cycle. Common side effects of DTIC include nausea, vomiting, impaired liver and kidney function, myelosuppression, and pneumonia. There are no accounts, however, of histological and hematological changes caused by DTIC. We investigated acute hematological and morphological changes in different organs and in tumors that were caused by a single dose of DTIC. Adult Syrian golden hamsters were inoculated with a suspension of tumorigenic baby hamster kidney (BHK) cells by subcutaneous injection. On day 14 after inoculation, doses of 1.4, 1.6, 1.8 or 2.0 g/m(2) DTIC were injected intraperitoneally into the hamsters. Hamsters in the control group were injected with physiological saline in the same way. Seven days after drug or saline injection the animals were sacrificed and samples of blood, heart, kidney, liver, lungs, spleen, small intestine and tumor were excised, processed and analyzed. Mitoses were counted using an ocular extension with engraved frame. Anemia, thrombocytopenia and leukocytosis were found in the control group of hamsters with fibrosarcoma, whereas animals with fibrosarcoma treated with DTIC developed anemia, thrombocytopenia and leukopenia. Severe pneumonia and moderate hepatitis were detected in all DTIC treated groups. Effects of DTIC on tumor cells included rounding and enlargement of nuclei and rarefaction of chromatin. The number of mitoses was reduced with increasing doses of DTIC. Hepatitis, myelosuppression, pneumonia, and dose-related inhibition of tumor cell proliferation were observed after a single dose of DTIC.
Eiden, C; Meniane, J C; Peyrière, H; Eymard-Duvernay, S; Le Falher, G; Ceballos, P; Fegueux, N; Cociglio, M; Reynes, J; Hillaire-Buys, D
2012-02-01
Posaconazole (PCZ) is given at 200 mg three times daily as a fungal prophylaxis in neutropenic hematologic malignancy patients. A relationship between exposure, plasma concentration, and efficacy is suggested. The objectives of this prospective study were to analyze the PCZ plasma concentration in hematology adults at high risk of developing invasive fungal infections (IFIs), and factors that could have an impact on the PCZ plasma concentration. PCZ plasma concentrations were measured after 2, 7, 10, 14, and 21 days of PCZ prophylaxis. Factors such as gender, age, body weight, posology, treatment duration, mucositis, proton pump inhibitor (PPI) use, and food intake were studied. Sixty-three patients were included, with a median age of 52 years (range 17-70) and a median weight of 75 kg (range 47-150). The median PCZ plasma concentration of the 63 patients ranged from 0.42 to 0.48 mg/L. At day 2, 30% of PCZ plasma concentration were under 0.35 mg/L, and at day 7, 74% were <0.70 mg/L. PCZ plasma concentrations were not affected by gender, age, body weight, or treatment duration. We found that food intake had a high influence on PCZ plasma concentrations (p = 0.0049). PCZ was well tolerated. One patient has developed a probable IFI, probably related to a low exposure to PCZ. PCZ therapeutic drug monitoring (TDM) is essential in order to early detect patients with low concentrations, to assess the etiology of such results, and to decide on the treatment strategy to apply.
Panani, Anna D
2009-04-01
The occasional observation of constitutional chromosomal abnormalities in patients with a malignant disease has led to a number of studies on their potential role in cancer development. Investigations of families with hereditary cancers and constitutional chromosomal abnormalities have been key observations leading to the molecular identification of specific genes implicated in tumorigenesis. Large studies have been reported on the incidence of constitutional chromosomal aberrations in patients with hematologic malignancies, but they could not confirm an increased risk for hematologic malignancy among carriers of structural chromosomal changes. However, it is of particular interest that constitutional structural aberrations with breakpoints similar to leukemia-associated specific breakpoints have been reported in patients with hematologic malignancies. Because of insufficient data, it remains still unclear if these aberrations represent random events or are associated with malignancy. There has been a substantial discussion about mechanisms involved in constitutional structural chromosomal changes in the literature. The documentation of more patients with constitutional structural chromosomal changes could be of major importance. Most importantly, the molecular investigation of chromosomal regions involved in rearrangements could give useful information on the genetic events underlying constitutional anomalies, contributing to isolation of genes important in the development of the neoplastic process. Regarding constitutional anomalies in patients with hematologic disorders, a survey of the cytogenetic data of our cytogenetics unit is herein also presented.
ABCB1-1Delta polymorphism can predict hematologic toxicity in dogs treated with vincristine.
Mealey, K L; Fidel, J; Gay, J M; Impellizeri, J A; Clifford, C A; Bergman, P J
2008-01-01
Dogs that harbor the naturally occurring ABCB1-1Delta polymorphism experience increased susceptibility to avermectin-induced neurological toxicosis as a result of deficient P-glycoprotein function. Whether or not the ABCB1-1Delta polymorphism affects susceptibility to toxicity of other P-glycoprotein substrate drugs has not been studied. Dogs that possess the ABCB1-1Delta mutation are more likely to develop hematologic toxicity associated with vincristine than ABCB1 wild-type dogs. Thirty-four dogs diagnosed with lymphoma were included in this study. Cheek swab samples were obtained from dogs diagnosed with lymphoma that were to be treated with vincristine. DNA was extracted from cheek swabs and the ABCB1 genotype was determined. Hematologic adverse drug reactions were recorded for each dog and graded according to the Veterinary Comparative Oncology Group's criteria for adverse event reporting (Consensus Document). In order to avoid possible bias, ABCB1 genotype results for a particular patient were not disclosed to oncologists until an initial adverse event report had been submitted. Dogs heterozygous or homozygous for the ABCB1-1Delta mutation were significantly more likely to develop hematologic toxicity, specifically neutropenia (P= .0005) and thrombocytopenia (P= .0001), after treatment with vincristine than ABCB1 wild-type dogs. At currently recommended dosages (0.5-0.7 mg/M(2)), vincristine is likely to cause hematologic toxicity in dogs with the ABCB1-1Delta mutation, resulting in treatment delays and unacceptable morbidity and mortality. Assessing the ABCB1-1Delta genotype before vincristine administration and decreasing the dosage may prevent toxicity and treatment delays resulting from neutropenia or thrombocytopenia.
Dutton, Christopher J; Taylor, Peter
2003-03-01
Snakes from temperate climates are often made to hibernate in zoos to stimulate reproduction. Unfortunately, deaths have occurred during and after hibernation. This study evaluated the health status, pre- and posthibernation, of 31 adult viperid snakes. It included morphometric measurements, hematology, and blood chemistry. No differences were seen in body weights and weight to length ratios between pre- and posthibernation examinations, suggesting that the overall condition of the snakes did not change. No differences were seen in hematologic and blood chemistry parameters, except that bile acids (3alpha-hydroxybile acids) decreased, the implications of which are unknown. Three individuals had markedly high plasma uric acid levels posthibernation; of these, two individuals died from extensive visceral gout and one recovered with fluid therapy. Viperid snakes should be clinically healthy, well hydrated, and in good body condition when they are put into hibernation. They should be maintained in an environment with sufficient humidity and should have access to water. Blood samples should be collected on arousal for measuring plasma uric acid levels. Changes in morphometry, hematology, and blood chemistry appear to be abnormal and should be investigated thoroughly.
Improvement of Binary Analysis Components in Automated Malware Analysis Framework
2017-02-21
analyze malicious software (malware) with minimum human interaction. The system autonomously analyze malware samples by analyzing malware binary program...AFRL-AFOSR-JP-TR-2017-0018 Improvement of Binary Analysis Components in Automated Malware Analysis Framework Keiji Takeda KEIO UNIVERSITY Final...currently valid OMB control number . PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ORGANIZATION. 1. REPORT DATE (DD-MM-YYYY) 21-02-2017 2. REPORT
NASA Technical Reports Server (NTRS)
Ciciora, J. A.; Leonard, S. D.; Johnson, N.; Amell, J.
1984-01-01
In order to derive general design guidelines for automated systems a study was conducted on the utilization and acceptance of existing automated systems as currently employed in several commercial fields. Four principal study area were investigated by means of structured interviews, and in some cases questionnaires. The study areas were aviation, a both scheduled airline and general commercial aviation; process control and factory applications; office automation; and automation in the power industry. The results of over eighty structured interviews were analyzed and responses categoried as various human factors issues for use by both designers and users of automated equipment. These guidelines address such items as general physical features of automated equipment; personnel orientation, acceptance, and training; and both personnel and system reliability.
Zatloukal, Jan; Pouska, Jiri; Kletecka, Jakub; Pradl, Richard; Benes, Jan
2016-12-01
The laboratory analysis provides accurate, but time consuming hemoglobin level estimation especially in the emergency setting. The reliability of time-sparing point of care devices (POCT) remains uncertain. We tested two POCT devices accuracy (HemoCue ® 201 + and Gem ® Premier™3000) in routine emergency department workflow. Blood samples taken from patients admitted to the emergency department were analyzed for hemoglobin concentration using a laboratory reference Beckman Coulter LH 750 (HB LAB ), the HemoCue (HB HC ) and the Gem Premier 3000 (HB GEM ). Pairwise comparison for each device and Hb LAB was performed using correlation and the Bland-Altman methods. The reliability of transfusion decision was assessed using three-zone error grid. A total of 292 measurements were performed in 99 patients. Mean hemoglobin level were 115 ± 33, 110 ± 28 and 111 ± 30 g/l for Hb HC , Hb GEM and Hb LAB respectively. A significant correlation was observed for both devices: Hb HC versus Hb LAB (r 2 = 0.93, p < 0.001) and HB GEM versus HB LAB (r 2 = 0.86, p < 0.001). The Bland-Altman method revealed bias of -3.7 g/l (limits of agreement -20.9 to 13.5) for HB HC and HB LAB and 2.5 g/l (-18.6 to 23.5) for HB GEM and HB LAB , which significantly differed between POCT devices (p < 0.001). Using the error grid methodology: 94 or 91 % of values (Hb HC and Hb GEM ) fell in the zone of acceptable difference (A), whereas 0 and 1 % (Hb HC and Hb GEM ) were unacceptable (zone C). The absolute accuracy of tested POCT devices was low though reaching a high level of correlation with laboratory measurement. The results of the Morey´s error grid were unfavorable for both POCT devices.
Using Publish-Subscribe Messaging for System Status and Automation
NASA Technical Reports Server (NTRS)
Smith, Danford S.
2015-01-01
The NASA Goddard Mission Services Evolution Center (GMSEC) system is a message-based plug-and-play open system architecture used in many of NASA mission operations centers. This presentation will focus on the use of GMSEC standard messages to report and analyze the status of a system and enable the automation of the system's components. In GMSEC systems, each component reports its status using a keep-alive message and also publishes status and activities as log messages. In addition, the components can accept functional directive messages from the GMSEC message bus. Over the past several years, development teams have found ways to utilize these messages to create innovative display pages and increasingly sophisticated approaches to automation. This presentation will show the flexibility and value of the message-based approach to system awareness and automation.
Early post-partum hematological changes in Holstein dairy cows with retained placenta.
Moretti, Pierangelo; Probo, Monica; Morandi, Nicola; Trevisi, Erminio; Ferrari, Annarita; Minuti, Andrea; Venturini, Monica; Paltrinieri, Saverio; Giordano, Alessia
2015-01-01
Retained placenta (RP) occurs frequently in dairy cattle but little is known about the pathogenic or prognostic role of the hematological changes in this disease. This retrospective study was designed to investigate the hematological changes associated with RP in the immediate post-partum period and to assess whether these changes are associated with an acute phase reaction. Data concerning hematology, acute phase proteins, markers of inflammation and serum biochemistry performed on cows at 3±1 days in milk (DIM) from two intensive farms were extracted from the database of the ProZoo project, a research project aimed to investigate the relationship between genomic traits and bovine health and production. After application of restrictive inclusion criteria, data from 45 cows, 22 with RP and 23 controls, were statistically compared. RBC count, d-ROMs concentration, and AST activity were significantly higher in the RP group than controls. Conversely, neutrophils, thiol groups, and serum zinc concentration were significantly lower in the RP group than controls. In conclusion, although retained placenta has to be considered as a syndrome with multifactorial causes, neutropenia may be a co-factor involved in its pathogenesis. Further studies are needed to clarify whether neutropenia acts as a contributor in the pathogenesis of RP or if it is a very early consequence of the syndrome, preceding any other inflammatory changes in blood. Copyright © 2014 Elsevier B.V. All rights reserved.
Hematological Profile and Martial Status in Rugby Players during Whole Body Cryostimulation
Lombardi, Giovanni; Lanteri, Patrizia; Porcelli, Simone; Mauri, Clara; Colombini, Alessandra; Grasso, Dalila; Zani, Viviana; Bonomi, Felice Giulio; Melegati, Gianluca; Banfi, Giuseppe
2013-01-01
Cold-based therapies are commonly applied to alleviate pain symptoms secondary to inflammatory diseases, but also to treat injuries or overuse, as done in sports rehabilitation. Whole body cryotherapy, a relatively new form of cold therapy, consists of short whole-body exposure to extremely cold air (−110°C to −140°C). Cryostimulation is gaining wider acceptance as an effective part of physical therapy to accelerate muscle recovery in rugby players. The aim of this study was to evaluate the effect of repeated cryostimulation sessions on the hematological profile and martial status markers in professional rugby players. Twenty-seven professional rugby players received 2 daily cryostimulation treatments for 7 consecutive days. Blood samples were collected before and after administration of the cryotherapic protocol and hematological profiles were obtained. No changes in the leukocyte count or composition were seen. There was a decrease in the values for erythrocytes, hematocrit, hemoglobin and mean corpuscular hemoglobin content, and an increase in mean corpuscular volume and red cell distribution width. Platelet count and mean volume remained unchanged. Serum transferrin and ferritin decreased, while soluble transferrin receptor increased. Serum iron and transferrin saturation were unchanged, as was reticulocyte count, whereas the immature reticulocyte fraction decreased substantially. In conclusion, in this sample of professional rugby players, cryostimulation modified the hematological profile, with a reduction in erythrocyte count and hemoglobinization paralleled by a change in martial status markers. PMID:23383348
Complementary and alternative medicine use in patients with hematological cancers in Malaysia.
Gan, G G; Leong, Y C; Bee, P C; Chin, E; Teh, A K H
2015-08-01
Complementary and alternative medicine (CAM) is often used by cancer patients, but not many studies had been published on the prevalence of CAM use in patients with hematological cancers. This study aims to determine the prevalence of CAM and type of CAM used in this group of patients in a multiracial and multicultural country. This is a cross-sectional survey carried out in two hospitals in Malaysia. Patients with underlying hematological cancers were asked to complete the questionnaires on CAM and the Hospital Anxiety and Depression Scale. A total of 245 patients participated. The prevalence of CAM use was 70.2 %. The most common types of CAM used are biological-based therapies (90.2 %) and mind-body interventions (42 %). Vitamin and diet supplements (68.6 %) and folk/herb remedies (58 %) are the most common biological-based therapies used. There is no significant association of CAM use with age, gender, education level, and household income. Female patients are more likely to use more than one CAM therapies. The most common reason reported for CAM use was to boost immunity (57 %) and cure (24 %). Majority of patients (65 %) felt CAM was effective, and 60 % did not inform their physicians regarding CAM usage. In view of the high prevalence of CAM use in patients with hematological cancers, it is important that the physicians play an active role in seeking information from patients and to monitor possible drug-vitamin-herbal interactions.
Sui, Jiang-Dong; Wang, Ying; Wan, Yue; Wu, Yong-Zhong
2018-01-01
Programmed cell death-1 (PD-1) inhibitor-related hematologic toxicities are a category of rare but clinically serious and potentially life-threatening adverse events; however, little is known about their risks across different treatment regimens and tumor types. The objective of this study was to compare the incidences of PD-1 inhibitor-related hematologic toxicities among different therapeutic regimens and tumor types. Twenty-six original articles on PD-1 inhibitor trials were identified based on a PubMed search completed on September 26, 2017. The incidences of hematologic toxicities were collected. A total of 26 studies containing 5,088 patients were included in the meta-analysis. PD-1 inhibitor monotherapy was associated with an increased risk of all-grade anemia in cancer patients (5%, 95% CI 4%-6%), particularly in patients with renal cell carcinoma (RCC) (8%, 95% CI 6%-12%), compared with all-grade thrombocytopenia (2%, 95% CI 1%-5%), leukopenia (2%, 95% CI 1%-3%), and neutropenia (1%, 95% CI 0-1%). However, low incidences of high-grade hematologic toxicities were observed in cancer patients treated with PD-1 inhibitor monotherapy. The use of PD-1 inhibitors in combination with ipilimumab, peptide vaccines, or chemotherapy had significantly higher risks than PD-1 inhibitor monotherapy for all-grade anemia (13%, 95% CI 5%-31%), thrombocytopenia (6%, 95% CI 2%-18%), leukopenia (5%, 95% CI 1%-35%), neutropenia (4%, 95% CI 1%-26%), and only high-grade thrombocytopenia (4%, 95% CI 1%-15%). In addition, all-grade and high-grade hematologic toxicities in chemotherapy and everolimus treatment arms were more frequent than in PD-1 inhibitor monotherapy arms. The risks of PD-1 inhibitor-related hematologic toxicities were higher in RCC than in other cancers, and during combination therapy. These results may contribute toward enhancing awareness among clinicians about frequent clinical monitoring when managing PD-1 inhibitors.