Science.gov

Sample records for automated radiometric technic

  1. Rapid recovery of mycobacteria from clinical specimens using automated radiometric technic

    SciTech Connect

    Park, C.H.; Hixon, D.L.; Ferguson, C.B.; Hall, S.L.; Risheim, C.C.; Cook, C.B.

    1984-03-01

    Automated radiometric technic (BACTEC Johnston Laboratories, Towson, MD) was compared with conventional mycobacterial culture procedure (Lowenstein-Jensen plus Gruft modification of Lowenstein-Jensen) in this study of 1,000 clinical specimens. In addition, 8-azaguanine inhibition was tested by radiometric technic as a rapid procedure for the differentiation of Mycobacterium tuberculosis from other mycobacterial species. A total of 59 mycobacteria was recovered. Of 28 clinically significant isolates (M. tuberculosis, M. kansasii, M. avium, M. fortuitum), the BACTEC system detected 26 (93%). Conventional methods recovered 23 (82%). The BACTEC system required an average of seven days to recover M. tuberculosis from smear-positive specimens compared with 18 days required by Lowenstein-Jensen or Gruft slants. From smear-negative specimens, the BACTEC detected M. tuberculosis in an average of 20 days versus 28 days by conventional procedure. All 20 isolates of M. tuberculosis were inhibited by 8-azaguanine, whereas 39 isolates of mycobacteria other than M. tuberculosis were not inhibited. The BACTEC system accomplishes more rapid recovery of mycobacteria and provides a higher yield than conventional methods.

  2. Automated geographic registration and radiometric correction for UAV-based mosaics

    NASA Astrophysics Data System (ADS)

    Thomasson, J. Alex; Shi, Yeyin; Sima, Chao; Yang, Chenghai; Cope, Dale A.

    2017-05-01

    Texas A and M University has been operating a large-scale, UAV-based, agricultural remote-sensing research project since 2015. To use UAV-based images in agricultural production, many high-resolution images must be mosaicked together to create an image of an agricultural field. Two key difficulties to science-based utilization of such mosaics are geographic registration and radiometric calibration. In our current research project, image files are taken to the computer laboratory after the flight, and semi-manual pre-processing is implemented on the raw image data, including ortho-mosaicking and radiometric calibration. Ground control points (GCPs) are critical for high-quality geographic registration of images during mosaicking. Applications requiring accurate reflectance data also require radiometric-calibration references so that reflectance values of image objects can be calculated. We have developed a method for automated geographic registration and radiometric correction with targets that are installed semi-permanently at distributed locations around fields. The targets are a combination of black (≍5% reflectance), dark gray (≍20% reflectance), and light gray (≍40% reflectance) sections that provide for a transformation of pixel-value to reflectance in the dynamic range of crop fields. The exact spectral reflectance of each target is known, having been measured with a spectrophotometer. At the time of installation, each target is measured for position with a real-time kinematic GPS receiver to give its precise latitude and longitude. Automated location of the reference targets in the images is required for precise, automated, geographic registration; and automated calculation of the digital-number to reflectance transformation is required for automated radiometric calibration. To validate the system for radiometric calibration, a calibrated UAV-based image mosaic of a field was compared to a calibrated single image from a manned aircraft. Reflectance

  3. Automated radiometric cryoprobe of IR focal plane array wafers

    NASA Astrophysics Data System (ADS)

    Whicker, Stephen L.

    1994-07-01

    Texas Instruments (TI) validated the feasibility of cryoprobing IRFPA arrays in late 1991. Since then, TI has developed a revolutionary automated cryoprobe for screening four and six inch wafers of IRFPAs. Generic prober automation features include cassette to cassette wafer load and unload, wafer alignment, black body selection, aperture selection, probe tip continuity test, and 77.5 degree(s) to 400 degree(s)K wafer temperature control. Modular construction of the prober enables placement of product specific components such as MWIR or LWIR bandpass filters, coldshield, coldfilter, probe card, and noise suppression circuitry on an easily removable `product specific' tooling plate. Prober operation is controlled through object oriented software. IRFPA specific software modules control array operation, data collection, and data reduction. In addition to describing the prober capabilities and versatility, this paper compares prober test data to lab dewar test data for 240 X 1 IRFPAs and projects benefits in reduced cycle time and labor savings.

  4. An Automated Curriculum Development Process for Navy Technical Training.

    ERIC Educational Resources Information Center

    Cantor, Jeffrey A.

    1988-01-01

    Describes a microcomputer-based program created for the U.S. Navy that automates curriculum development for technical training. Highlights include training program components; analysis and design of instructional materials; systematic support and management of the curriculum development process; software automation; and time and cost savings. (LRW)

  5. TurboTech Technical Evaluation Automated System

    NASA Technical Reports Server (NTRS)

    Tiffany, Dorothy J.

    2009-01-01

    TurboTech software is a Web-based process that simplifies and semiautomates technical evaluation of NASA proposals for Contracting Officer's Technical Representatives (COTRs). At the time of this reporting, there have been no set standards or systems for training new COTRs in technical evaluations. This new process provides boilerplate text in response to interview style questions. This text is collected into a Microsoft Word document that can then be further edited to conform to specific cases. By providing technical language and a structured format, TurboTech allows the COTRs to concentrate more on the actual evaluation, and less on deciding what language would be most appropriate. Since the actual word choice is one of the more time-consuming parts of a COTRs job, this process should allow for an increase in quantity of proposals evaluated. TurboTech is applicable to composing technical evaluations of contractor proposals, task and delivery orders, change order modifications, requests for proposals, new work modifications, task assignments, as well as any changes to existing contracts.

  6. Automated Cataloging of Technical Reports Via Optical Scanning

    ERIC Educational Resources Information Center

    Stiles, Helen J.; Maier, Joan M.

    1972-01-01

    A system for automated cataloging of technical reports was established during 1971. The twice-per-month output is an updated book catalog, an announcement bulletin, demand bibliographies, and an SDI notification system. Benefits include a 600 percent increase in report usage and a 10 percent decrease in catalog maintenance. (Author/NH)

  7. Automated radioanalytical system incorporating microwave-assisted sample preparation, chemical separation, and online radiometric detection for the monitoring of total 99Tc in nuclear waste processing streams.

    PubMed

    Egorov, Oleg B; O'Hara, Matthew J; Grate, Jay W

    2012-04-03

    An automated fluidic instrument is described that rapidly determines the total (99)Tc content of aged nuclear waste samples, where the matrix is chemically and radiologically complex and the existing speciation of the (99)Tc is variable. The monitor links microwave-assisted sample preparation with an automated anion exchange column separation and detection using a flow-through solid scintillator detector. The sample preparation steps acidify the sample, decompose organics, and convert all Tc species to the pertechnetate anion. The column-based anion exchange procedure separates the pertechnetate from the complex sample matrix, so that radiometric detection can provide accurate measurement of (99)Tc. We developed a preprogrammed spike addition procedure to automatically determine matrix-matched calibration. The overall measurement efficiency that is determined simultaneously provides a self-diagnostic parameter for the radiochemical separation and overall instrument function. Continuous, automated operation was demonstrated over the course of 54 h, which resulted in the analysis of 215 samples plus 54 hly spike-addition samples, with consistent overall measurement efficiency for the operation of the monitor. A sample can be processed and measured automatically in just 12.5 min with a detection limit of 23.5 Bq/mL of (99)Tc in low activity waste (0.495 mL sample volume), with better than 10% RSD precision at concentrations above the quantification limit. This rapid automated analysis method was developed to support nuclear waste processing operations planned for the Hanford nuclear site.

  8. Project for an Automated Centre for Scientific and Technical Information in the People's Republic of Bulgaria

    ERIC Educational Resources Information Center

    Simeonov, S.; Andrianova, R.

    1975-01-01

    An automated Centre for Scientific and Technical Information has been set up within the Bulgarian Central Institute for Scientific and Technical Information, with United Nations Development Programme assistance and with Unesco as executing agency for the project. (Author)

  9. [Laser-based radiometric calibration].

    PubMed

    Li, Zhi-gang; Zheng, Yu-quan

    2014-12-01

    Increasingly higher demands are put forward to spectral radiometric calibration accuracy and the development of new tunable laser based spectral radiometric calibration technology is promoted, along with the development of studies of terrestrial remote sensing, aeronautical and astronautical remote sensing, plasma physics, quantitative spectroscopy, etc. Internationally a number of national metrology scientific research institutes have built tunable laser based spectral radiometric calibration facilities in succession, which are traceable to cryogenic radiometers and have low uncertainties for spectral responsivity calibration and characterization of detectors and remote sensing instruments in the UK, the USA, Germany, etc. Among them, the facility for spectral irradiance and radiance responsivity calibrations using uniform sources (SIRCCUS) at the National Institute of Standards and Technology (NIST) in the USA and the Tunable Lasers in Photometry (TULIP) facility at the Physikalisch-Technische Bundesanstalt (PTB) in Germany have more representatives. Compared with lamp-monochromator systems, laser based spectral radiometric calibrations have many advantages, such as narrow spectral bandwidth, high wavelength accuracy, low calibration uncertainty and so on for radiometric calibration applications. In this paper, the development of laser-based spectral radiometric calibration and structures and performances of laser-based radiometric calibration facilities represented by the National Physical Laboratory (NPL) in the UK, NIST and PTB are presented, technical advantages of laser-based spectral radiometric calibration are analyzed, and applications of this technology are further discussed. Laser-based spectral radiometric calibration facilities can be widely used in important system-level radiometric calibration measurements with high accuracy, including radiance temperature, radiance and irradiance calibrations for space remote sensing instruments, and promote the

  10. Aquarius's Instrument Science Data System (ISDS) Automated to Acquire, Process, Trend Data and Produce Radiometric System Assessment Reports

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The Aquarius Radiometer, a subsystem of the Aquarius Instrument required a data acquisition ground system to support calibration and radiometer performance assessment. To support calibration and compose performance assessments, we developed an automated system which uploaded raw data to a ftp server and saved raw and processed data to a database. This paper details the overall functionalities of the Aquarius Instrument Science Data System (ISDS) and the individual electrical ground support equipment (EGSE) which produced data files that were infused into the ISDS. Real time EGSEs include an ICDS Simulator, Calibration GSE, Labview controlled power supply, and a chamber data acquisition system. ICDS Simulator serves as a test conductor primary workstation, collecting radiometer housekeeping (HK) and science data and passing commands and HK telemetry collection request to the radiometer. Calibration GSE (Radiometer Active Test Source) provides source choice from multiple targets for the radiometer external calibration. Power Supply GSE, controlled by labview, provides real time voltage and current monitoring of the radiometer. And finally the chamber data acquisition system produces data reflecting chamber vacuum pressure, thermistor temperatures, AVG and watts. Each GSE system produce text based data files every two to six minutes and automatically copies the data files to the Central Archiver PC. The Archiver PC stores the data files, schedules automated uploads of these files to an external FTP server, and accepts request to copy all data files to the ISDS for offline data processing and analysis. Aquarius Radiometer ISDS contains PHP and MATLab programs to parse, process and save all data to a MySQL database. Analysis tools (MATLab programs) in the ISDS system are capable of displaying radiometer science, telemetry and auxiliary data in near real time as well as performing data analysis and producing automated performance assessment reports of the Aquarius

  11. Aquarius's Instrument Science Data System (ISDS) Automated to Acquire, Process, Trend Data and Produce Radiometric System Assessment Reports

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The Aquarius Radiometer, a subsystem of the Aquarius Instrument required a data acquisition ground system to support calibration and radiometer performance assessment. To support calibration and compose performance assessments, we developed an automated system which uploaded raw data to a ftp server and saved raw and processed data to a database. This paper details the overall functionalities of the Aquarius Instrument Science Data System (ISDS) and the individual electrical ground support equipment (EGSE) which produced data files that were infused into the ISDS. Real time EGSEs include an ICDS Simulator, Calibration GSE, Labview controlled power supply, and a chamber data acquisition system. ICDS Simulator serves as a test conductor primary workstation, collecting radiometer housekeeping (HK) and science data and passing commands and HK telemetry collection request to the radiometer. Calibration GSE (Radiometer Active Test Source) provides source choice from multiple targets for the radiometer external calibration. Power Supply GSE, controlled by labview, provides real time voltage and current monitoring of the radiometer. And finally the chamber data acquisition system produces data reflecting chamber vacuum pressure, thermistor temperatures, AVG and watts. Each GSE system produce text based data files every two to six minutes and automatically copies the data files to the Central Archiver PC. The Archiver PC stores the data files, schedules automated uploads of these files to an external FTP server, and accepts request to copy all data files to the ISDS for offline data processing and analysis. Aquarius Radiometer ISDS contains PHP and MATLab programs to parse, process and save all data to a MySQL database. Analysis tools (MATLab programs) in the ISDS system are capable of displaying radiometer science, telemetry and auxiliary data in near real time as well as performing data analysis and producing automated performance assessment reports of the Aquarius

  12. Sequential injection separation system with stopped-flow radiometric detection for automated analysis of (99)tc in nuclear waste.

    PubMed

    Egorov, O; O'Hara, M J; Ruzicka, J; Grate, J W

    1998-03-01

    An automated procedure for the determination of (99)Tc in aged nuclear waste has been developed. Using advanced sequential injection (SI) analysis instrumentation, (99)Tc(VII) is separated from radioactive and stable interferences using a TEVA resin column that selectively retains pertechnetate ion from dilute nitric acid solutions. The separated (99)Tc is eluted with 6 M nitric acid and quantified on-line with a flow-through liquid scintillation detector. A stopped-flow technique has been optimized that improves the analysis precision and detection limit compared to continuous-flow detection, reduces consumption of liquid scintillation cocktail, and increases sample throughput by separating the next sample while the present sample is being counted. The detection limit is 30 pCi, or 2 ng, of (99)Tc, using a 15-min stopped-flow period. The analysis time is 40 min for the first sample and is reduced to 20 min for each subsequent sample. Processed nuclear waste samples from the Hanford site were successfully analyzed by this new method.

  13. SeaWiFS technical report series. Volume 23: SeaWiFS prelaunch radiometric calibration and spectral characterization

    NASA Technical Reports Server (NTRS)

    Barnes, Robert A.; Holmes, Alan W.; Barnes, William L.; Esaias, Wayne E.; Mcclain, Charles R.; Svitek, Tomas; Hooker, Stanford B.; Firestone, Elaine R.; Acker, James G.

    1994-01-01

    Based on the operating characteristics of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS), calibration equations have been developed that allow conversion of the counts from the radiometer into Earth-existing radiances. These radiances are the geophysical properties the instrument has been designed to measure. SeaWiFS uses bilinear gains to allow high sensitivity measurements of ocean-leaving radiances and low sensitivity measurements of radiances from clouds, which are much brighter than the ocean. The calculation of these bilinear gains is central to the calibration equations. Several other factors within these equations are also included. Among these are the spectral responses of the eight SeaWiFS bands. A band's spectral response includes the ability of the band to isolate a portion of the electromagnetic spectrum and the amount of light that lies outside of that region. The latter is termed out-of-band response. In the calibration procedure, some of the counts from the instrument are produced by radiance in the out-of-band region. The number of those counts for each band is a function of the spectral shape of the source. For the SeaWiFS calibration equations, the out-of-band responses are converted from those for the laboratory source into those for a source with the spectral shape of solar flux. The solar flux, unlike the laboratory calibration, approximates the spectral shape of the Earth-existing radiance from the oceans. This conversion modifies the results from the laboratory radiometric calibration by 1-4 percent, depending on the band. These and other factors in the SeaWiFS calibration equations are presented here, both for users of the SeaWiFS data set and for researchers making ground-based radiance measurements in support of Sea WiFS.

  14. SeaWiFS Postlaunch Technical Report Series. Volume 4; The 1997 Prelaunch Radiometric Calibration of SeaWiFS

    NASA Technical Reports Server (NTRS)

    Hooker, Stanford B. (Editor); Firestone, Elaine R. (Editor); Johnson, B. Carol; Early, Edward E.; Eplee, Robert E., Jr.; Barnes, Robert A.; Caffrey, Robert T.

    1999-01-01

    The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) was originally calibrated by the instrument's manufacturer, Santa Barbara Research Center (SBRC), in November 1993. In preparation for an August 1997 launch, the SeaWiFS Project and the National Institute of Standards and Technology (NIST) undertook a second calibration of SeaWiFS in January and April 1997 at the facility of the spacecraft integrator, Orbital Sciences Corporation (OSC). This calibration occurred in two phases, the first after the final thermal vacuum test, and the second after the final vibration test of the spacecraft. For the calibration, SeaWiFS observed an integrating sphere from the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) at four radiance levels. The spectral radiance of the sphere at these radiance levels was also measured by the SeaWiFS Transfer Radiometer (SXR). In addition, during the calibration, SeaWiFS and the SXR observed the sphere at 16 radiance levels to determine the linearity of the SeaWiFS response. As part of the calibration analysis, the GSFC sphere was also characterized using a GSFC spectroradiometer. The 1997 calibration agrees with the initial 1993 calibration to within +/- 4%. The new calibration coefficients, computed before and after the vibration test, agree to within 0.5%. The response of the SeaWiFS channels in each band is linear to better than 1%. In order to compare to previous and current methods, the SeaWiFS radiometric responses are presented in two ways: using the nominal center wave-lengths for the eight bands; and using band-averaged spectral radiances. The band-averaged values are used in the flight calibration table. An uncertainty analysis for the calibration coefficients is also presented.

  15. An Automated Circulation System for a Small Technical Library.

    ERIC Educational Resources Information Center

    Culnan, Mary J.

    The traditional manually-controlled circulation records of the Burroughs Corporation Library in Goleta, California, presented problems of inaccuracies, time time-consuming searches, and lack of use statistics. An automated system with the capacity to do file maintenance and statistical record-keeping was implemented on a Burroughts B1700 computer.…

  16. An Automated Circulation System for a Small Technical Library.

    ERIC Educational Resources Information Center

    Culnan, Mary J.

    The traditional manually-controlled circulation records of the Burroughs Corporation Library in Goleta, California, presented problems of inaccuracies, time time-consuming searches, and lack of use statistics. An automated system with the capacity to do file maintenance and statistical record-keeping was implemented on a Burroughts B1700 computer.…

  17. Radiometric sounding system

    SciTech Connect

    Whiteman, C.D.; Anderson, G.A.; Alzheimer, J.M.; Shaw, W.J.

    1995-04-01

    Vertical profiles of solar and terrestrial radiative fluxes are key research needs for global climate change research. These fluxes are expected to change as radiatively active trace gases are emitted to the earth`s atmosphere as a consequence of energy production and industrial and other human activities. Models suggest that changes in the concentration of such gases will lead to radiative flux divergences that will produce global warming of the earth`s atmosphere. Direct measurements of the vertical variation of solar and terrestrial radiative fluxes that lead to these flux divergences have been largely unavailable because of the expense of making such measurements from airplanes. These measurements are needed to improve existing atmospheric radiative transfer models, especially under the cloudy conditions where the models have not been adequately tested. A tethered-balloon-borne Radiometric Sounding System has been developed at Pacific Northwest Laboratory to provide an inexpensive means of making routine vertical soundings of radiative fluxes in the earth`s atmospheric boundary layer to altitudes up to 1500 m above ground level. Such vertical soundings would supplement measurements being made from aircraft and towers. The key technical challenge in the design of the Radiometric Sounding System is to develop a means of keeping the radiometers horizontal while the balloon ascends and descends in a turbulent atmospheric environment. This problem has been addressed by stabilizing a triangular radiometer-carrying platform that is carried on the tetherline of a balloon sounding system. The platform, carried 30 m or more below the balloon to reduce the balloon`s effect on the radiometric measurements, is leveled by two automatic control loops that activate motors, gears and pulleys when the platform is off-level. The sensitivity of the automatic control loops to oscillatory motions of various frequencies and amplitudes can be adjusted using filters.

  18. Automation and the Workplace. Selected Labor, Education, and Training Issues. A Technical Memorandum.

    ERIC Educational Resources Information Center

    Congress of the U.S., Washington, DC. Office of Technology Assessment.

    This technical memorandum discusses procedures for evaluating potential employment change associated with automation and outlines associated problems. It also describes the nature and modes of delivery of education, training, and retraining for persons holding or seeking employment in manufacturing industries. An introduction provides a brief…

  19. Development Trends in Federal Library and Information Center Automation. Guides for Administrative and Technical Interviews.

    ERIC Educational Resources Information Center

    Information Dynamics Corp., Bethesda, MD.

    These two guides for interviews on trends in library automation in federal libraries and information centers cover administrative and technical interviews. The guide for administrative interviews is divided into five steps: (1) determining the details of the agency's mission and organizational structure, (2) establishing the administrative…

  20. Maintenance Technical Manuals: Format Descriptions and Guidelines for Automated Presentation.

    DTIC Science & Technology

    1985-12-01

    regardless of the media by which the information i.esented. Even though the baseline presentation system *.si’ma tel for the automated delivery system... media (i.e., CRT presentation was not a consideration). Nevertheless, some guidance can be provided based on the findings of the limited CRT color...INCH SPACING. CONNECTE R LINKAGE SVSTEN TO A CEA N E L SE RANK . TV! BILL. CR:AN, A LLOWS TH SALES TO SE DOE N EDAD COE ANIL " H MP SCvB IS COM POSED

  1. NASA Radiometric Characterization

    NASA Technical Reports Server (NTRS)

    Holekamp, Kara

    2006-01-01

    This viewgraph presentation reviews the characterization of radiometric data by NASA. The objective was to perform radiometric vicarious calibrations of imagery and compare with vendor-provided calibration coefficients. The approach was to use multiple, well-characterized sites. These sites are widely used by the NASA science community for radiometric characterization of airborne and space borne sensors. Using the data from these sites, the investigators performed independent characterizations with independent teams. Each team has slightly different measurement techniques and data processing methods.

  2. NASA IKONOS Radiometric Characterization

    NASA Technical Reports Server (NTRS)

    Pagnutti, Mary; Frisbee, Troy; Zanoni, Vicki; Blonski, Slawek; Daehler, Erik; Grant, Brennan; Holekamp, Kara; Ryan, Robert; Sellers, Richard; Smith, Charles

    2002-01-01

    The objective of this program: Perform radiometric vicarious calibrations of IKQNOS imagery and compare with Space Imaging calibration coefficients The approach taken: utilize multiple well-characterized sites which are widely used by the NASA science community for radiometric characterization of airborne and spaceborne sensors; and to Perform independent characterizations with independent teams. Each team has slightly different measurement techniques and data processing methods.

  3. Transportable educational programs for scientific and technical professionals: More effective utilization of automated scientific and technical data base systems

    NASA Technical Reports Server (NTRS)

    Dominick, Wayne D.

    1987-01-01

    This grant final report executive summary documents a major, long-term program addressing innovative educational issues associated with the development, administration, evaluation, and widespread distribution of transportable educational programs for scientists and engineers to increase their knowledge of, and facilitate their utilization of automated scientific and technical information storage and retrieval systems. This educational program is of very broad scope, being targeted at Colleges of Engineering and Colleges of Physical sciences at a large number of colleges and universities throughout the United States. The educational program is designed to incorporate extensive hands-on, interactive usage of the NASA RECON system and is supported by a number of microcomputer-based software systems to facilitate the delivery and usage of the educational course materials developed as part of the program.

  4. Radiometric correction procedure study

    NASA Technical Reports Server (NTRS)

    Colby, C.; Sands, R.; Murphrey, S.

    1978-01-01

    A comparison of MSS radiometric processing techniques identified as a preferred radiometric processing technique a procedure which equalizes the mean and standard deviation of detector-specific histograms of uncalibrated scene data. Evaluation of MSS calibration data demonstrated that the relationship between detector responses is essentially linear over the range of intensities typically observed in MSS data, and that the calibration wedge data possess a high degree of temporal stability. An analysis of the preferred radiometric processing technique showed that it could be incorporated into the MDP-MSS system without a major redesign of the system, and with minimal impact on system throughput.

  5. Radiometric instrumentation and measurements guide for photovoltaic performance testing

    SciTech Connect

    Myers, D.

    1997-04-01

    The Photovoltaic Module and Systems Performance and Engineering Project at the National Renewable Energy Laboratory performs indoor and outdoor standardization, testing, and monitoring of the performance of a wide range of photovoltaic (PV) energy conversion devices and systems. The PV Radiometric Measurements and Evaluation Team (PVSRME) within that project is responsible for measurement and characterization of natural and artificial optical radiation which stimulates the PV effect. The PV manufacturing and research and development community often approaches project members for technical information and guidance. A great area of interest is radiometric instrumentation, measurement techniques, and data analysis applied to understanding and improving PV cell, module, and system performance. At the Photovoltaic Radiometric Measurements Workshop conducted by the PVSRME team in July 1995, the need to communicate knowledge of solar and optical radiometric measurements and instrumentation, gained as a result of NREL`s long-term experiences, was identified as an activity that would promote improved measurement processes and measurement quality in the PV research and manufacturing community. The purpose of this document is to address the practical and engineering need to understand optical and solar radiometric instrument performance, selection, calibration, installation, and maintenance applicable to indoor and outdoor radiometric measurements for PV calibration, performance, and testing applications. An introductory section addresses radiometric concepts and definitions. Next, concepts essential to spectral radiometric measurements are discussed. Broadband radiometric instrumentation and measurement concepts are then discussed. Each type of measurement serves as an important component of the PV cell, module, and system performance measurement and characterization process.

  6. The Candela and Photometric and Radiometric Measurements

    PubMed Central

    Parr, Albert C.

    2001-01-01

    The national measurement system for photometric and radiometric quantities is presently based upon techniques that make these quantities traceable to a high-accuracy cryogenic radiometer. The redefinition of the candela in 1979 provided the opportunity for national measurement laboratories to base their photometric measurements on optical detector technology rather than on the emission from high-temperature blackbody optical sources. The ensuing technical developments of the past 20 years, including the significant improvements in cryogenic radiometer performance, have provided the opportunity to place the fundamental maintenance of photometric quantities upon absolute detector based technology as was allowed by the 1979 redefinition. Additionally, the development of improved photodetectors has had a significant impact on the methodology in most of the radiometric measurement areas. This paper will review the status of the NIST implementation of the technical changes mandated by the 1979 redefinition of the candela and its effect upon the maintenance and dissemination of optical radiation measurements. PMID:27500020

  7. Broadband Radiometric LED Measurements

    PubMed Central

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2017-01-01

    At present, broadband radiometric measurements of LEDs with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed. PMID:28649167

  8. Small satellite radiometric measurements

    SciTech Connect

    Weber, P.G.

    1991-01-01

    A critical need for the Mission to Planet Earth is to provide continuous, well-calibrated radiometric data for the radiation budget. This paper describes a new, compact, flexible radiometer which will provide both spectrally integrated data and data in selected spectral bands. The radiometer design is suitable for use on small satellites, aircraft, or remotely piloted vehicles (RPVs). 12 refs., 2 figs.

  9. Broadband radiometric LED measurements

    NASA Astrophysics Data System (ADS)

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2016-09-01

    At present, broadband radiometric LED measurements with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed.

  10. Radiometric Dating Does Work!

    ERIC Educational Resources Information Center

    Dalrymple, G. Brent

    2000-01-01

    Discusses the accuracy of dating methods and creationist arguments that radiometric dating does not work. Explains the Manson meteorite impact and the Pierre shale, the ages of meteorites, the K-T tektites, and dating the Mount Vesuvius eruption. (Author/YDS)

  11. Radiometric Dating Does Work!

    ERIC Educational Resources Information Center

    Dalrymple, G. Brent

    2000-01-01

    Discusses the accuracy of dating methods and creationist arguments that radiometric dating does not work. Explains the Manson meteorite impact and the Pierre shale, the ages of meteorites, the K-T tektites, and dating the Mount Vesuvius eruption. (Author/YDS)

  12. Photovoltaics radiometric issues and needs

    SciTech Connect

    Myers, D.R.

    1995-11-01

    This paper presents a summary of issues discussed at the photovoltaic radiometric measurements workshop. Topics included radiometric measurements guides, the need for well-defined goals, documentation, calibration checks, accreditation of testing laboratories and methods, the need for less expensive radiometric instrumentation, data correlations, and quality assurance.

  13. [Technical requirements for early defibrillation: what are the capabilities of automated external defibrillators].

    PubMed

    Israel, C W; Grönefeld, G

    2005-06-01

    Modern automated external defibrillators (AEDs) offer a variety of technical improvements which increase the efficacy of early defibrillation, facilitate the application by not or minimally trained persons and improve safety. The development of biphasic shocks allows better myocardial protection, the use of lithium batteries, and a marked decrease of AEDs, in size. Microprocessors realize complex acoustic and visual prompts which lead the user through all steps of cardiopulmonary resuscitation (CPR) according to current guidelines. The design of AEDs has been simplified; many devices provide only a single button which can be used for all active processes. Memory functions record the whole CPR with all details which can be transferred to other computers and analyzed off-line. The introduction of AEDs has reduced the delay between collapse and defibrillation to less than 4 min in several studies thus increasing the success of CPR and the proportion of patients dismissed from hospital alive and without neurological deficit. Up to 93% of untrained volunteers were able to successfully complete defibrillation with the use of an AED, sixth-form pupils without experience in CPR were only few sec slower with an AED than staff of emergency medical services. The ability to perform CPR after defibrillation guided by the AED depends primarily on the clarity of acoustic prompts which have to consider the terms and abbreviations of the respective language. Currently available AEDs surpass performance goals of the AHA. However, all devices exhibit advantages and disadvantages which will be discussed in this review.

  14. Evaluation of the Fully Automated BACTEC MGIT 960 System for Testing Susceptibility of Mycobacterium tuberculosis to Pyrazinamide, Streptomycin, Isoniazid, Rifampin, and Ethambutol and Comparison with the Radiometric BACTEC 460TB Method

    PubMed Central

    Scarparo, Claudio; Ricordi, Paolo; Ruggiero, Giuliana; Piccoli, Paola

    2004-01-01

    The performance of the fully automated BACTEC MGIT 960 (M960) system for the testing of Mycobacterium tuberculosis susceptibility to streptomycin (SM), isoniazid (INH), rifampin (RMP), ethambutol (EMB), and pyrazinamide (PZA) was evaluated with 100 clinical isolates and compared to that of the radiometric BACTEC 460TB (B460) system. The agar proportion method and the B460 system were used as reference methods to resolve the discordant results for SM, INH, RMP, and EMB (a combination known as SIRE) and PZA, respectively. The overall agreements were 96.3% for SIRE and 92% for PZA. For SIRE, a total of 26 discrepancies were found and were resolved in favor of the M960 system in 8 cases and in favor of the B460 system in 18 cases. The M960 system produced 8 very major errors (VME) and 10 major errors (ME), while the B460 system showed 4 VME and 4 ME. No statistically significant differences were found. Both systems exhibited excellent performance, but a higher number of VME was observed with the M960 system at the critical concentrations of EMB and SM. For PZA, a total of eight discrepancies were observed and were resolved in favor of the M960 system in one case and in favor of the B460 system in seven cases; no statistically significant differences were found. The M960 system showed four VME and three ME. The mean times to report overall PZA results and resistant results were 8.2 and 9.8 days, respectively, for the M960 system and 7.4 and 8.1 days, respectively, for the B460 system. Statistically significant differences were found. The mean times to report SIRE results were 8.3 days for the M960 system and 8.2 days for the B460 system. No statistically significant differences were found. Twelve strains tested for SIRE susceptibility and seven strains tested for PZA susceptibility had been reprocessed because of contamination. In conclusion, the M960 system can represent a valid alternative to the B460 for M. tuberculosis susceptibility testing; however, the frequent

  15. Simplified Vicarious Radiometric Calibration

    NASA Technical Reports Server (NTRS)

    Stanley, Thomas; Ryan, Robert; Holekamp, Kara; Pagnutti, Mary

    2010-01-01

    A measurement-based radiance estimation approach for vicarious radiometric calibration of spaceborne multispectral remote sensing systems has been developed. This simplified process eliminates the use of radiative transfer codes and reduces the number of atmospheric assumptions required to perform sensor calibrations. Like prior approaches, the simplified method involves the collection of ground truth data coincident with the overpass of the remote sensing system being calibrated, but this approach differs from the prior techniques in both the nature of the data collected and the manner in which the data are processed. In traditional vicarious radiometric calibration, ground truth data are gathered using ground-viewing spectroradiometers and one or more sun photometer( s), among other instruments, located at a ground target area. The measured data from the ground-based instruments are used in radiative transfer models to estimate the top-of-atmosphere (TOA) target radiances at the time of satellite overpass. These TOA radiances are compared with the satellite sensor readings to radiometrically calibrate the sensor. Traditional vicarious radiometric calibration methods require that an atmospheric model be defined such that the ground-based observations of solar transmission and diffuse-to-global ratios are in close agreement with the radiative transfer code estimation of these parameters. This process is labor-intensive and complex, and can be prone to errors. The errors can be compounded because of approximations in the model and inaccurate assumptions about the radiative coupling between the atmosphere and the terrain. The errors can increase the uncertainty of the TOA radiance estimates used to perform the radiometric calibration. In comparison, the simplified approach does not use atmospheric radiative transfer models and involves fewer assumptions concerning the radiative transfer properties of the atmosphere. This new technique uses two neighboring uniform

  16. Verification of the radiometric map of the Czech Republic.

    PubMed

    Matolín, Milan

    2017-01-01

    The radiometric map of the Czech Republic is based on uniform regional airborne radiometric total count measurements (1957-1959) which covered 100% of the country. The airborne radiometric instrument was calibrated to a (226)Ra point source. The calibration facility for field gamma-ray spectrometers, established in the Czech Republic in 1975, significantly contributed to the subsequent radiometric data standardization. In the 1990's, the original analogue airborne radiometric data were digitized and using the method of back-calibration (IAEA, 2003) converted to dose rate. The map of terrestrial gamma radiation expressed in dose rate (nGy/h) was published on the scale 1:500,000 in 1995. Terrestrial radiation in the Czech Republic, formed by magmatic, sedimentary and metamorphic rocks of Proterozoic to Quaternary age, ranges mostly from 6 to 245 nGy/h, with a mean of 65.6 ± 19.0 nGy/h. The elevated terrestrial radiation in the Czech Republic, in comparison to the global dose rate average of 54 nGy/h, reflects an enhanced content of natural radioactive elements in the rocks. The 1995 published radiometric map of the Czech Republic was successively studied and verified by additional ground gamma-ray spectrometric measurements and by comparison to radiometric maps of Germany, Poland and Slovakia in border zones. A ground dose rate intercomparison measurement under participation of foreign and domestic professional institutions revealed mutual dose rate deviations about 20 nGy/h and more due to differing technical parameters of applied radiometric instruments. Studies and verification of the radiometric map of the Czech Republic illustrate the magnitude of current deviations in dose rate data. This gained experience can assist in harmonization of dose rate data on the European scale. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Advancing automation and robotics technology for the space station and for the US economy. Volume II: technical report

    SciTech Connect

    Not Available

    1985-03-01

    In response to Public Law 98-371, dated July 18, 1984, the NASA Advanced Technology Advisory Committee has studied automation and robotics for use in the Space Station and prepared this report to the congressional Committees on Appropriations. The study has included work by groups both within NASA and outside NASA, in the academic and industrial communities. The report is divided into two volumes. The Policy Report, Volume I, summaizes the major findings of the study and establishes NASA policy for advancing automation and robotics technologies to use them in the Space Station and to benefit the US economy. The Technical Report, Volume II (this document), provides background information on automation and robotics technologies and their potential and documents the following: the relevant aspects of Space Station design; representative examples of automation and robotics applications; the state of the technology and advances needed; and considerations for technology transfer to US industry and for space commercialization. Volume II provides guidance for prospective Space Station contractors to direct their efforts toward a planned advance in these technologies.

  18. Automated space processing payloads study. Volume 2, book 1: Technical report. [instrument packages and space shuttles

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The extent was investigated to which experiment hardware and operational requirements can be met by automatic control and material handling devices; payload and system concepts that make extensive use of automation technology are defined. Hardware requirements for each experiment were established and tabulated, and investigations of applicable existing hardware were documented. The capabilities and characteristics of industrial automation equipment, controls, and techniques are presented in the form of a summary of applicable equipment characteristics in three basic mutually-supporting formats. Facilities for performing groups of experiments are defined along with four levitation groups and three furnace groups; major hardware elements required to implement them were identified. A conceptual design definition of ten different automated processing facilities is presented along with the specific equipment to implement each facility and the design layouts of the different units. Constraints and packaging, weight, and power requirements for six payloads postulated for shuttle missions in the 1979 to 1982 time period were examined.

  19. Radiometric and Spectral Measurement Instruments

    DTIC Science & Technology

    1992-03-18

    NSWCCR/RDTN-92/0003 AD-A250 771LI~ llliii11l li l l iillt111 RADIOMETRIC AND SPECTRAL MEASUREMENT INSTRUMENTS CRANE DIVISION NAVAL SURFACE WARFARE... INSTRUMENTS 6. AUTHOR(S) B. E. DOUDA H. A. WEBSTER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) a. PERFORMING ORGANIZATION REPORT NIJMBER...Maxiry-um 200 w ords) THIS IS A DESCRIPTION OF AN ASSORTMENT OF RADIOMETRIC AND SPECTRAL INSTRUMENTATION USED FOR MEASUREMENT OF THE RADIATIVE OUTPUT OF

  20. Radiometric Navigation Update

    NASA Astrophysics Data System (ADS)

    Nettles, James L.; Witsmeer, A. James; Wilt, Robert E.

    1980-12-01

    Boeing Aerospace Company (BAC) of Seattle, Washington and Sperry Microwave Electronics of Clearwater, Florida have developed a multiple-beam radiometric navigation update system. This paper describes the system design, flight test program, and preliminary results. The system was designed and its performance evaluated using analytically derived formulas for performance measures and detailed Monte Carlo simulations. As a result BAC recommended a five or seven fixed beam radiometer. Sperry built a seven-beam, 35 GHz radiometer which BAC flight tested in 1979 to demonstrate its effectiveness over a variety of test scenes under various environmental conditions. Four scenes were selected for the flight test varying from land-water to highly forested regions. Preliminary analysis of the flight test results confirm the expected performance improvement over the single-fixed-beam system tested in 1975. This approach to a terrain sensing millimeter wave radiometer would be applicable to low altitude penetrating aircraft. The system is low cost, with no moving parts; low volume, requiring only a single receiver with small wide-beam antennas; and stealthy, being completely passive. Radiometry can also be complementary to todays terrain correlation approach since flat areas usually contain a maximum of cultural features; where one system works poorly the other works well. This test program provides a data base for studying a wide variety of pattern matching and correlation algorithms, with and without attitude compensation, and using various subsets of the full seven-beam combination.

  1. Scientific and technical services directed toward the development of planetary quarantine measures for automated spacecraft

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Planetary quarantine requirements and parameters are evaluated for their effects upon automated spacecraft flights data describing the heat resistance of naturally occuring microorganisms and sterilization requirements are analyzed and a possible method for assessment of these data is developed. Pertinent data from planetary mission microbial contamination logs are compiled and maintained in the quarantine document system.

  2. Scientific and technical services in the development of planetary quarantine measures for automated spacecraft

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Primary goals of the Planetary Quarantine Program are defined and used to provide a basis for planning and source allocation toward the development of planetary quarantine measures for the following automated spacecrafts: Viking 1975, Pioneer F and G, and Mariner Venus-Mercury 1973.

  3. Automation and Reorganization of Technical and Public Services. SPEC Kit 112.

    ERIC Educational Resources Information Center

    Busch, B. J.

    This SPEC (Systems and Procedures Exchange Center) kit is based partially on the results of a fall, 1984 survey of the 117 Association of Research Libraries (ARL) members to determine the extent to which they have reorganized staff and the role played by automation in planning organizational change. Particular attention was paid to the integration…

  4. Space station automation study. Volume 2: Technical report. Autonomous systems and assembly

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The application of automation to space station functions is discussed. A summary is given of the evolutionary functions associated with long range missions and objectives. Mission tasks and requirements are defined. Space station sub-systems, mission models, assembly, and construction are discussed.

  5. Automated water monitor system field demonstration test report. Volume 2: Technical summary

    NASA Technical Reports Server (NTRS)

    Brooks, R. L.; Jeffers, E. L.; Perreira, J.; Poel, J. D.; Nibley, D.; Nuss, R. H.

    1981-01-01

    The NASA Automatic Water Monitor System was installed in a water reclamation facility to evaluate the technical and cost feasibility of producing high quality reclaimed water. Data gathered during this field demonstration test are reported.

  6. Uncooled radiometric camera performance

    NASA Astrophysics Data System (ADS)

    Meyer, Bill; Hoelter, T.

    1998-07-01

    Thermal imaging equipment utilizing microbolometer detectors operating at room temperature has found widespread acceptance in both military and commercial applications. Uncooled camera products are becoming effective solutions to applications currently using traditional, photonic infrared sensors. The reduced power consumption and decreased mechanical complexity offered by uncooled cameras have realized highly reliable, low-cost, hand-held instruments. Initially these instruments displayed only relative temperature differences which limited their usefulness in applications such as Thermography. Radiometrically calibrated microbolometer instruments are now available. The ExplorIR Thermography camera leverages the technology developed for Raytheon Systems Company's first production microbolometer imaging camera, the Sentinel. The ExplorIR camera has a demonstrated temperature measurement accuracy of 4 degrees Celsius or 4% of the measured value (whichever is greater) over scene temperatures ranges of minus 20 degrees Celsius to 300 degrees Celsius (minus 20 degrees Celsius to 900 degrees Celsius for extended range models) and camera environmental temperatures of minus 10 degrees Celsius to 40 degrees Celsius. Direct temperature measurement with high resolution video imaging creates some unique challenges when using uncooled detectors. A temperature controlled, field-of-view limiting aperture (cold shield) is not typically included in the small volume dewars used for uncooled detector packages. The lack of a field-of-view shield allows a significant amount of extraneous radiation from the dewar walls and lens body to affect the sensor operation. In addition, the transmission of the Germanium lens elements is a function of ambient temperature. The ExplorIR camera design compensates for these environmental effects while maintaining the accuracy and dynamic range required by today's predictive maintenance and condition monitoring markets.

  7. Training of Technical Services Staff in the Automated Environment. SPEC Kit 171.

    ERIC Educational Resources Information Center

    Bakke, Celia; Whitlach, Jo Bell

    For this kit, 119 Association of Research Libraries (ARL) academic libraries were surveyed to determine the impact of online catalogs on the training needs of technical services staff and on the planning and organization of programs to meet these needs; responses were received from 66 libraries. Analyses of the responses indicated that the…

  8. The Design and Production of a Procedure Training Aid Using the Procedure Learning Format and the Computer Automated Page Layout (PLA) Routine. Technical Note 12-83.

    ERIC Educational Resources Information Center

    Terrell, William R.; And Others

    This report describes a field application of the Computer Automated Page Layout (PLA) system to the development of a procedure training aid for the SH-3D/H Helicopter, as part of the Training Analysis and Evaluation Group's (TAEG) ongoing development effort to provide tools for the design and publication of technical training aids in a format…

  9. New York City Police Department Automated Fuel Monitoring system. Volume II. Documentation report. Technical report

    SciTech Connect

    McGrath, W.J.; McNamara, M.M.

    1981-11-16

    The New York City Police Department (NYCPD) Automated Fuel Monitoring system is briefly described from the original study, through system design, to implementation. The system provides complete control of fuel usage for an agency with 4,000 motor vehicles and 25,000 vehicle operators. As far as is known, it is the largest system of its kind installed to date. The system can be scaled up or down to meet the needs of other governmental units. Estimated annual cost savings to NYCPD are $2,000,000.

  10. Radiometric framework for image mosaicking.

    PubMed

    Litvinov, Anatoly; Schechner, Yoav Y

    2005-05-01

    Nonuniform exposures often affect imaging systems, e.g., owing to vignetting. Moreover, the sensor's radiometric response may be nonlinear. These characteristics hinder photometric measurements. They are particularly annoying in image mosaicking, in which images are stitched to enhance the field of view. Mosaics suffer from seams stemming from radiometric inconsistencies between raw images. Prior methods feathered the seams but did not address their root cause. We handle these problems in a unified framework. We suggest a method for simultaneously estimating the radiometric response and the camera nonuniformity, based on a frame sequence acquired during camera motion. The estimated functions are then compensated for. This permits image mosaicking, in which no seams are apparent. There is no need to resort to dedicated seam-feathering methods. Fundamental ambiguities associated with this estimation problem are stated.

  11. Airborne microwave radiometric imaging system

    NASA Astrophysics Data System (ADS)

    Guo, Wei; Zhang, Zuyin; Chen, Zhengwen

    1998-08-01

    A dual channel Airborne Microwave Radiometric Imaging system (AMRI) was designed and constructed for regional environment mapping. The system operates at 35GHz, which collects radiation at horizontal and vertical polarized. It runs at mechanical conical scanning with 45 degrees incidence angle. Two Cassegrain antennas with 1.5 degrees 3 dB beamwidth scan the scene alternately and two pseudo-color images of two channels are displayed on the screen of PC in real time. Simultaneously all parameters of flight and radiometric data are stored in hard disk for postprocessing. The sensitivity of the radiometers of flight and radiometric data are stored in hard disk for postprocessing. The sensitivity of the radiometers (Delta) T equals 0.16K. A new display method, unequal size element arc displaying method, is used in image displaying. Several experiments on mobile tower were carried out and the images demonstrate the AMRI is available to work steadily and accurately.

  12. Automation of the Duplicate Checking Function at DTIC (Defense Technical Information Center). Part 1. Overview,

    DTIC Science & Technology

    1982-05-01

    DUPLICATE CHECKING FUNCTION AT DTIC " PART 1 : OVERVIEW i *’ ’. F Allan D. Kuhn Gladys A. Cotter - P May 192. % F 4. .... Defense Technical Information...Superseded) and Cancelled Notes. These notes were not displayed online. When a record number that had been replaced or cancelled was p displayed online...Catalogers Skeletal uprecord (RTIS) edited "referral nd (retrieval) nformation (retrieval) P De criptive c talog ing (RTIS) r cord YES Recdo mple Spti

  13. Study of Spectral/Radiometric Characteristics of the Thematic Mapper for Land Use Applications

    NASA Technical Reports Server (NTRS)

    Malila, W. A. (Principal Investigator); Metzler, M. D. (Principal Investigator)

    1985-01-01

    An investigation conducted in support of the LANDSAT 4/5 Image Data Quality Analysis (LIDQA) Program is discussed. Results of engineering analyses of radiometric, spatial, spectral, and geometric properties of the Thematic Mapper systems are summarized; major emphasis is placed on the radiometric analysis. Details of the analyses are presented in appendices, which contain three of the eight technical papers produced during this investigation; these three, together, describe the major activities and results of the investigation.

  14. Grid-Competitive Residential and Commercial Fully Automated PV Systems Technology: Final technical Report, August 2011

    SciTech Connect

    Brown, Katie E.; Cousins, Peter; Culligan, Matt; Jonathan Botkin; DeGraaff, David; Bunea, Gabriella; Rose, Douglas; Bourne, Ben; Koehler, Oliver

    2011-08-26

    Under DOE's Technology Pathway Partnership program, SunPower Corporation developed turn-key, high-efficiency residential and commercial systems that are cost effective. Key program objectives include a reduction in LCOE values to 9-12 cents/kWh and 13-18 cents/kWh respectively for the commercial and residential markets. Target LCOE values for the commercial ground, commercial roof, and residential markets are 10, 11, and 13 cents/kWh. For this effort, SunPower collaborated with a variety of suppliers and partners to complete the tasks below. Subcontractors included: Solaicx, SiGen, Ribbon Technology, Dow Corning, Xantrex, Tigo Energy, and Solar Bridge. SunPower's TPP addressed nearly the complete PV value chain: from ingot growth through system deployment. Throughout the award period of performance, SunPower has made progress toward achieving these reduced costs through the development of 20%+ efficient modules, increased cell efficiency through the understanding of loss mechanisms and improved manufacturing technologies, novel module development, automated design tools and techniques, and reduced system development and installation time. Based on an LCOE assessment using NREL's Solar Advisor Model, SunPower achieved the 2010 target range, as well as progress toward 2015 targets.

  15. Evaluation of an Automated Reflectance Microscope system for coal characterization. Technical report 18

    SciTech Connect

    Liscinsky, D. S.; Vastola, F.

    1980-01-01

    The potential of an Automated Reflectance Microscope (ARM) system to determine the petrographic composition of a coal has been examined. The analysis involves the automatic scanning of a polished coal surface with a reflectance microscope. The reflectivity of consecutive 4-square-micrometer spots on the surface is measured by a photomultiplier tube and recorded by a microcomputer. This study was aimed at making the interpretation of a reflectogram more straightforward, that is, increasing the ability to discriminate among species. Although hardware improvements to decrease the spot size and the error associated with each reading would allow some increase in the ability to discriminate among species, the heterogeneous nature of the surface still limits the qualitative and quantitative information that can be derived from a reflectogram. Therefore a real-time data processing algorithm was implemented during data acquisition to study the effects that processing can have on a reflectogram. By measuring connectivity, it was found that edge readings could be indirectly eliminated. This greatly improved the ability to discriminate among species. Further investigation led to the conclusion that physical particle size has a major effect on a reflectogram. The concentration of coal in a pellet also has an effect on the ability to discriminate among species. A bonus of using processing to enhance the data was the ability to simultaneously gather information on particle size distributions. Based on the results the potential of an ARM system is improved by algorithm enhancement. The processing of the data allows some of the inherent limitations to be reduced.

  16. Detection of coliform organisms in drinking water by radiometric method.

    PubMed

    Khurshid, S J; Bibi, S

    1991-07-01

    The radiometric method has been used for detection of coliform bacteria in water. The method is based on measuring the released metabolic 14CO2 from 14C-lactose in growth media containing coliform organisms incubated at 37 degrees C under continuous shaking. This rapid and sensitive radiometric method permits the detection of even single coliform organisms within 6 hours of incubation. Using this automated method, a total of 102 samples (in duplicate) collected from different areas in and around Rawalpindi and Islamabad were assessed for coliform bacteria. Of these 102 samples, 50 were tap water samples, 40 from wells and 6 each were from Rawal and Simly dams. About 47% and 67% tap water samples, while 62% and 74% well water samples were found unsatisfactory from around Islamabad and Rawalpindi areas, respectively. About 83% and 66% water samples from Rawal dam and Simly dam respectively were found to be unsatisfactory.

  17. A configuration space toolkit for automated spatial reasoning: Technical results and LDRD project final report

    SciTech Connect

    Xavier, P.G.; LaFarge, R.A.

    1997-02-01

    A robot`s configuration space (c-space) is the space of its kinematic degrees of freedom, e.g., the joint-space of an arm. Sets in c-space can be defined that characterize a variety of spatial relationships, such as contact between the robot and its environment. C-space techniques have been fundamental to research progress in areas such as motion planning and physically-based reasoning. However, practical progress has been slowed by the difficulty of implementing the c-space abstraction inside each application. For this reason, we proposed a Configuration Space Toolkit of high-performance algorithms and data structures meeting these needs. Our intent was to develop this robotics software to provide enabling technology to emerging applications that apply the c-space abstraction, such as advanced motion planning, teleoperation supervision, mechanism functional analysis, and design tools. This final report presents the research results and technical achievements of this LDRD project. Key results and achievements included (1) a hybrid Common LISP/C prototype that implements the basic C-Space abstraction, (2) a new, generic, algorithm for constructing hierarchical geometric representations, and (3) a C++ implementation of an algorithm for fast distance computation, interference detection, and c-space point-classification. Since the project conclusion, motion planning researchers in Sandia`s Intelligent Systems and Robotics Center have been using the CSTk libcstk.so C++ library. The code continues to be used, supported, and improved by projects in the ISRC.

  18. Airborne microwave radiometric imaging system

    NASA Astrophysics Data System (ADS)

    Guo, Wei; Li, Futang; Zhang, Zuyin

    1999-09-01

    A dual channel Airborne Microwave Radiometric Imaging system (AMRI) was designed and constructed for regional environment mapping. The system operates at 35GHz, which collects radiation at horizontal and vertical polarized channels. It runs at mechanical conical scanning with 45 degrees incidence angle. Two Cassegrain antennas with 1.5 degrees beamwidth scan the scene alternately and two pseudo- color images of two channels are displayed on the screen of PC in real time. Simultaneously, all parameters of flight and radiometric data are sorted in hard disk for post- processing. The sensitivity of the radiometer (Delta) T equals 0.16K. A new displaying method, unequal size element arc displaying method, is used in image displaying. Several experiments on mobile tower were carried out and the images demonstrate that the AMRI is available to work steadily and accurately.

  19. The Radiometric Map of Australia

    NASA Astrophysics Data System (ADS)

    Minty, Brian; Franklin, Ross; Milligan, Peter; Richardson, Murray; Wilford, John

    2009-12-01

    Geoscience Australia and the Australian State and Territory Geological Surveys have systematically surveyed most of the Australian continent over the past 40 years using airborne gamma-ray spectrometry to map potassium, uranium and thorium elemental concentrations at the Earth's surface. However, the individual surveys that comprise the national gamma-ray spectrometric radioelement database are not all registered to the same datum. This limits the usefulness of the database as it is not possible to easily combine surveys into regional compilations or make accurate comparisons between radiometric signatures in different survey areas. To solve these problems, Geoscience Australia has undertaken an Australia-Wide Airborne Geophysical Survey (AWAGS), funded under the Australian Government's Onshore Energy Security Program, to serve as a radioelement baseline for all current and future airborne gamma-ray spectrometric surveys in Australia. The AWAGS survey has been back-calibrated to the International Atomic Energy Agency's (IAEA) radioelement datum. We have used the AWAGS data to level the national radioelement database by estimating survey correction factors that, once applied, minimise both the differences in radioelement estimates between surveys (where these surveys overlap) and the differences between the surveys and the AWAGS traverses. The database is thus effectively levelled to the IAEA datum. The levelled database has been used to produce the first `Radiometric Map of Australia' - levelled and merged composite potassium (% K), uranium (ppm eU) and thorium (ppm eTh) grids over Australia at 100m resolution. Interpreters can use the map to reliably compare the radiometric signatures observed over different parts of Australia. This enables the assessment of key mineralogical and geochemical properties of bedrock and regolith materials from different geological provinces and regions with contrasting landscape histories.

  20. Radiometric studies of Mycobacterium lepraemurium.

    PubMed

    Camargo, E E; Larson, S M; Tepper, B S; Wagner, H N

    1976-01-01

    The radiometric method has been applied for studying the metabolism of M. lepraemurium and the conditions which might force or inhibit its metabolic activity in vitro. These organisms assimilate and oxidize (U-14C) glycerol, and (U-14C) acetate, but are unable to oxidize (U-14C) glucose, (U-14C) pyruvate, (U-14C) glycine and 14C-formate. When incubated at 30 degrees C M. lepraemurium oxidizes (U-14C) acetate to 14CO2 faster than 37 degrees C. The smae effect was observed with increasing concentrations of polysorbate 80 (Tween 80), or the 14C-substrate. No change in metabolic rate was observed when the organisms were kept at -20 degrees C for 12 days. Although tried several times, it was not possible to demonstrate any "inhibitors" of bacterial metabolism in the reaction system. The radiometric method seems to be an important tool for studying metabolic pathways and the influence of physical and biochemical factors on the metabolism of M. lepraemurium in vitro.

  1. Automation pilot

    NASA Technical Reports Server (NTRS)

    1983-01-01

    An important concept of the Action Information Management System (AIMS) approach is to evaluate office automation technology in the context of hands on use by technical program managers in the conduct of human acceptance difficulties which may accompany the transition to a significantly changing work environment. The improved productivity and communications which result from application of office automation technology are already well established for general office environments, but benefits unique to NASA are anticipated and these will be explored in detail.

  2. Radiometric correction of LANDSAT data

    NASA Technical Reports Server (NTRS)

    Dejesusparada, N.; Kumar, R. (Principal Investigator); Cavalcanti, L. A.

    1977-01-01

    The author has identified the following significant results. The six independent sensors of the multispectral band scanner are supposed to be identical; however, in actual practice, they may have different gain settings and offset factors, which result in the effect known as stripping (black lines at regular intervals) of the imagery. A simple two parameter method to correct the gain settings and offset factors of each of the sensors with respect to one sensor, taken as reference, was developed. This method assumes: (1) the response of a detector varies linearly with the radiance of radiation received, and (2) the means, as well as the standard deviations, of a reasonably large number of pixels, in a given wavelength band, are equal for each of the detectors for the radiometrically corrected data.

  3. Small satellite radiometric measurement system

    SciTech Connect

    Weber, P.G.

    1992-01-01

    A critical need for the US Global Change Research Program is to provide continuous, well-calibrated radiometric data for the earth's radiation budget. This paper describes a new, compact, relatively light-weight, adaptable radiometer which will provide both spectrally integrated measurements and data in selected spectral bands. The radiometer design is suitable for use on small satellites, aircraft, or remotely piloted aircraft (RPAs). An example of the implementation of this radiometer on a small satellite is given. Significant benefits derive from simultaneous measurements of specific narrow (in wavelength) spectral features; such data may be obtained by combining LARI with a compact spectrometer on the same platform. Well-chosen satellite orbits allow one to use data from other satellites (e.g. DMSP) to enhance the data product, or to provide superior coverage of specific locations. 23 refs.

  4. Small satellite radiometric measurement system

    SciTech Connect

    Weber, P.G.

    1992-01-01

    A critical need for the US Global Change Research Program is to provide continuous, well-calibrated radiometric data for the earth`s radiation budget. This paper describes a new, compact, relatively light-weight, adaptable radiometer which will provide both spectrally integrated measurements and data in selected spectral bands. The radiometer design is suitable for use on small satellites, aircraft, or remotely piloted aircraft (RPAs). An example of the implementation of this radiometer on a small satellite is given. Significant benefits derive from simultaneous measurements of specific narrow (in wavelength) spectral features; such data may be obtained by combining LARI with a compact spectrometer on the same platform. Well-chosen satellite orbits allow one to use data from other satellites (e.g. DMSP) to enhance the data product, or to provide superior coverage of specific locations. 23 refs.

  5. Extended- and Point-Source Radiometric Program

    DTIC Science & Technology

    1962-08-08

    Radiometric Measurements of Cs1 37 Sources Made with NaI Detector. . 60 6.2 Aerial Radiometric Measurements of Co 60 Sources Made with Bioplastic ...Hanford aircraft consisted of an NaI scintillator, bioplastic scintillator, and a 40-liter ionization chamber. The aircraft employed was a twin-engine...supply, amplifier, and count rate, was transistorized portable equipment designed and fabricated at Hanford. The bioplastic instrument consisted of a 5

  6. Lansat MSS, Radiometric Processing Improvement

    NASA Astrophysics Data System (ADS)

    Saunier, Sebastien; Salgues, Germain; Gascon, Ferran; Biaasutti, Roberto

    2016-08-01

    The reprocessing campaigns of Landsat European Space Agency (ESA) data archive have been initiated since 3 years [1]. As part of this project, the processing algorithms have been upgraded. This article focuses on the radiometric processing of historical data observed with the Multi Spectral Scanner (MSS) instruments on board Landsat 1, 2, 3, 4 and 5.The Landsat MSS data have been recorded data from 1972 up to 1990. The MSS instruments have been designed with four visible bands covering the near / infrared regions of the electromagnetic spectrum, allowing the spatial sampling of our Earth surface at 60 meter.The current calibration method has shown some limitations in case of data observed out of mid latitude areas, where the Earth surface is bright because of desert or snow. The resulting image data suffers from saturations and is not fit for the potential application purposes.Although, when saturation exist, further investigations have shown that the radiometry of the raw data involved in the production of the Level 1 images is generally correct. As consequences, experiments have been undertaken to adapt the current processing in order to produce image data saturation free products.

  7. Radiometric calibration updates to the Landsat collection

    NASA Astrophysics Data System (ADS)

    Micijevic, Esad; Haque, Md. Obaidul; Mishra, Nischal

    2016-09-01

    The Landsat Project is planning to implement a new collection management strategy for Landsat products generated at the U.S. Geological Survey (USGS) Earth Resources Observation and Science (EROS) Center. The goal of the initiative is to identify a collection of consistently geolocated and radiometrically calibrated images across the entire Landsat archive that is readily suitable for time-series analyses. In order to perform an accurate land change analysis, the data from all Landsat sensors must be on the same radiometric scale. Landsat 7 Enhanced Thematic Mapper Plus (ETM+) is calibrated to a radiance standard and all previous sensors are cross-calibrated to its radiometric scale. Landsat 8 Operational Land Imager (OLI) is calibrated to both radiance and reflectance standards independently. The Landsat 8 OLI reflectance calibration is considered to be most accurate. To improve radiometric calibration accuracy of historical data, Landsat 1-7 sensors also need to be cross-calibrated to the OLI reflectance scale. Results of that effort, as well as other calibration updates including the absolute and relative radiometric calibration and saturated pixel replacement for Landsat 8 OLI and absolute calibration for Landsat 4 and 5 Thematic Mappers (TM), will be implemented into Landsat products during the archive reprocessing campaign planned within the new collection management strategy. This paper reports on the planned radiometric calibration updates to the solar reflective bands of the new Landsat collection.

  8. Automated space processing payloads study. Volume 2, book 2: Technical report, appendices A through E. [instrument packages and space shuttles

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Experiment hardware and operational requirements for space shuttle experiments are discussed along with payload and system concepts. Appendixes are included in which experiment data sheets, chamber environmental control and monitoring, method for collection and storage of electrophoretically-separated samples, preliminary thermal evaluation of electromagnetic levitation facilities L1, L2, and L3, and applicable industrial automation equipment are discussed.

  9. Radiometric measurement of differential metabolism of fatty acid by mycobacteria.

    PubMed

    Camargo, E E; Kertcher, J A; Larson, S M; Tepper, B S; Wagner, H N

    1982-06-01

    An assay system has been developed based on automated radiometric quantification of 14CO2 produced through oxidation of [1-14C] fatty acids by mycobacteria. Two stains of M. tuberculosis (H37Rv and Erdman) and one of M. bovis (BCG) in 7H9 medium (ADC) with 1.0 microCi of one of the fatty acids (butyric, hexanoic, octanoic, decanoic, lauric, myristic, palmitic, stearic, oleic, linoleic and linolenic) were studied. Results previously published on M. lepraemurium (Hawaiian) were also included for comparison. Both strains of M. tuberculosis had maximum 14CO2 production from hexanoic acid. Oxidation of butyric and avid oxidation of lauric acids were also found with the H37Rv strain but not with Erdman. In contrast, 14CO2 production by M. bovis was greatest from lauric and somewhat less from decanoic acid. M. lepraemurium showed increasing oxidation rates from myristic, decanoic and lauric acids. Assimilation studies of M. tuberculosis H37Rv confirmed that most of the oxidized substrates were converted into by-products with no change in those from which no oxidation was found. These data suggest that the radiometric measurement of differential fatty acid metabolism may provide a basis of strain identification of the genus Mycobacterium.

  10. Radiometric Characterization of Hyperspectral Imagers using Multispectral Sensors

    NASA Technical Reports Server (NTRS)

    McCorkel, Joel; Kurt, Thome; Leisso, Nathan; Anderson, Nikolaus; Czapla-Myers, Jeff

    2009-01-01

    The Remote Sensing Group (RSG) at the University of Arizona has a long history of using ground-based test sites for the calibration of airborne and satellite based sensors. Often, ground-truth measurements at these test sites are not always successful due to weather and funding availability. Therefore, RSG has also automated ground instrument approaches and cross-calibration methods to verify the radiometric calibration of a sensor. The goal in the cross-calibration method is to transfer the calibration of a well-known sensor to that of a different sensor, This work studies the feasibility of determining the radiometric calibration of a hyperspectral imager using multispectral a imagery. The work relies on the Moderate Resolution Imaging Spectroradiometer (M0DIS) as a reference for the hyperspectral sensor Hyperion. Test sites used for comparisons are Railroad Valley in Nevada and a portion of the Libyan Desert in North Africa. Hyperion bands are compared to MODIS by band averaging Hyperion's high spectral resolution data with the relative spectral response of M0DlS. The results compare cross-calibration scenarios that differ in image acquisition coincidence, test site used for the calibration, and reference sensor. Cross-calibration results are presented that show agreement between the use of coincident and non-coincident image pairs within 2% in most brands as well as similar agreement between results that employ the different MODIS sensors as a reference.

  11. Radiometric surveys in underground environment

    NASA Astrophysics Data System (ADS)

    Bochiolo, Massimo; Chiozzi, Paolo; Verdoya, Massimo; Pasquale, Vincenzo

    2010-05-01

    Due to their ability to travel through the air for several metres, gamma-rays emitted from natural radioactive elements can be successfully used in surveys carried out both with airborne and ground equipments. Besides the concentration of the radio-elements contained in rocks and soils and the intrinsic characteristics of the gamma-ray detector, the detected count rate depends on the solid angle around the spectrometer. On a flat outcrop, ground spectrometry detects the radiation ideally produced by a cylindrical mass of rock of about two metres in diameter and thickness of about half a meter. Under these geometrical conditions, the natural radioactivity can be easily evaluated. With operating conditions different from the standard ones, such as at the edge of an escarpment, the count rate halves because of the missing material, whereas in the vicinity of a rock wall the count rate will increase. In underground environment, the recorded count rate may even double and the in situ assessment of the concentration of radio-elements may be rather difficult, even if the ratios between the different radio-elements may not be affected. We tested the applicability of gamma-ray spectrometry for rapid assessment of the potential hazard levels related to radon and radiation dose rate in underground environment. A mine shaft, located in a zone of uranium enrichment in Liguria (Italy), has been investigated. A preliminary ground radiometric survey was carried out to define the extent of the ore deposit. Then, the radiometric investigation was focussed on the mine shaft. Due to rock mass above the shaft vault, the background gamma radiation can be considered of negligible influence on measurements. In underground surveys, besides deviations from a flat geometry, factors controlling radon exhalation, emanation and stagnation, such as fractures, water leakage and the presence of ventilation, should be carefully examined. We attempted to evaluate these control factors and collected

  12. Technical aspects and evaluation methodology for the application of two automated brain MRI tumor segmentation methods in radiation therapy planning.

    PubMed

    Beyer, Gloria P; Velthuizen, Robert P; Murtagh, F Reed; Pearlman, James L

    2006-11-01

    The purpose of this study was to design the steps necessary to create a tumor volume outline from the results of two automated multispectral magnetic resonance imaging segmentation methods and integrate these contours into radiation therapy treatment planning. Algorithms were developed to create a closed, smooth contour that encompassed the tumor pixels resulting from two automated segmentation methods: k-nearest neighbors and knowledge guided. These included an automatic three-dimensional (3D) expansion of the results to compensate for their undersegmentation and match the extended contouring technique used in practice by radiation oncologists. Each resulting radiation treatment plan generated from the automated segmentation and from the outlining by two radiation oncologists for 11 brain tumor patients was compared against the volume and treatment plan from an expert radiation oncologist who served as the control. As part of this analysis, a quantitative and qualitative evaluation mechanism was developed to aid in this comparison. It was found that the expert physician reference volume was irradiated within the same level of conformity when using the plans generated from the contours of the segmentation methods. In addition, any uncertainty in the identification of the actual gross tumor volume by the segmentation methods, as identified by previous research into this area, had small effects when used to generate 3D radiation therapy treatment planning due to the averaging process in the generation of margins used in defining a planning target volume.

  13. The Electronic Delivery of Automated Technical Information for Logistics Support of Navy Weapon Systems: Potential, System Description and Status

    DTIC Science & Technology

    1989-02-01

    Charles S. Sawyer. Test and Evaluation of The Navy Technical Information Presentation System (NTIPS), AN/SPA-25D Test Results. DTRC-88-035, September 1988...L. LeBeau; Anne S. Mavor; Theodore J. Post; and Charles S. Sawyer. Test and Evaluation of The Navy Technical Information Presentpl ier System (NTIPS...Karpovich 1 EER Systems 1 NPFC-100 H. Bukowski LCDR F. Harmer 2 EG&G 1 NOSC WASC L. Snodgrass R. Smillie WASCI R. Beckham 1 NOS Indianhead 4 Essex Corp. G

  14. Rapid radiometric serum test for antibiotic activity.

    PubMed

    D'Antonio, R G; Camargo, E E; Gedra, T; Wagner, H N; Charache, P

    1982-02-01

    We have developed a 4-h radiometric method to predict the bacteriostatic endpoint by the tube dilution method. A mixture of [U-14C] glucose, [guanido-14C] arginine, and [U-14C] glycine was used to monitor the metabolic activity of both gram-positive and gram-negative organisms. The tube dilution method and the radiometric method were performed in parallel in 18 clinical serum samples. In the radiometric method, the samples were separated into control and test portions and serially diluted in Mueller-Hinton broth. Antibiotics in the control portion were inactivated with penicillinase or cellulose phosphate or both. The radioactive mixture and a 1-h culture of the patient's infecting organisms were added to all vials. The 14CO2 production after a 3-h incubation at 37 degrees C was measured, and the percent inhibition was determined for each vial by using the control vials as reference (no inhibition). Radiometric dose-response curves obtained for all samples showed that, by using a greater than or equal to 60% inhibition at 1:8 dilution, the radiometric method correctly predicted the outcome of the tube dilution method in 16 or 18 clinical samples.

  15. Technical note: Validation of a commercial system for the continuous and automated monitoring of dairy cow activity.

    PubMed

    Tullo, E; Fontana, I; Gottardo, D; Sloth, K H; Guarino, M

    2016-09-01

    Current farm sizes do not allow the precise identification and tracking of individual cows and their health and behavioral records. Currently, the application of information technology within intensive dairy farming takes a key role in proper routine management to improve animal welfare and to enhance the comfort of dairy cows. An existing application based on information technology is represented by the GEA CowView system (GEA Farm Technologies, Bönen, Germany). This system is able to detect and monitor animal behavioral activities based on positioning, through the creation of a virtual map of the barn that outlines all the areas where cows have access. The aim of this study was to validate the accuracy, sensitivity, and specificity of data provided by the CowView system. The validation was performed by comparing data automatically obtained from the CowView system with those obtained by a manual labeling procedure performed on video recordings. Data used for the comparisons were represented by the zone-related activities performed by the selected dairy cows and were classified into 2 categories: activity and localization. The duration in seconds of each of the activities/localizations detected both with the manual labeling and with the automated system were used to evaluate the correlation coefficients among data; and subsequently the accuracy, sensitivity, specificity, and positive and negative predictive values of the automated monitoring system were calculated. The results of this validation study showed that the CowView automated monitoring system is able to identify the cow localization/position (alley, trough, cubicles) with high reliability in relation to the zone-related activities performed by dairy cows (accuracy higher than 95%). The results obtained support the CowView system as an innovative potential solution for the easier management of dairy cows.

  16. Technical innovations for the automated identification of gel-separated proteins by MALDI-TOF mass spectrometry.

    PubMed

    Jahn, Olaf; Hesse, Dörte; Reinelt, Marina; Kratzin, Hartmut D

    2006-09-01

    The combination of gel-based two-dimensional protein separations with protein identification by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) is the workhorse for the large-scale analyses of proteomes. Such high-throughput proteomic approaches require automation of all post-separation steps and the in-gel digest of proteins especially is often the bottleneck in the protein identification workflow. With the objective of reaching the same high performance of manual low-throughput in-gel digest procedures, we have developed a novel stack-type digestion device and implemented it into a commercially available robotic liquid handling system. This modified system is capable of performing in-gel digest, extraction of proteolytic peptides, and subsequent sample preparation for MALDI-MS without any manual intervention, but with a performance at least identical to manual procedures as indicated on the basis of the sequence coverage obtained by peptide mass fingerprinting. For further refinement of the automated protein identification workflow, we have also developed a motor-operated matrix application device to reproducibly obtain homogenous matrix preparation of high quality. This matrix preparation was found to be suitable for the automated acquisition of both peptide mass fingerprint and fragment ion spectra from the same sample spot, a prerequisite for high confidence protein identifications on the basis of peptide mass and sequence information. Due to the implementation of the stack-type digestion device and the motor-operated matrix application device, the entire platform works in a reliable, cost-effective, and sensitive manner, yielding high confidence protein identifications even for samples in the concentration range of as low as 100 fmol protein per gel plug.

  17. Rapid radiometric susceptibility testing of Mycobacterium tuberculosis.

    PubMed

    Kertcher, J A; Chen, M F; Charache, P; Hwangbo, C C; Camargo, E E; McIntyre, P A; Wagner, H N

    1978-04-01

    A 48-hour radiometric test for determining the drug susceptibility of Mycobacterium tuberculosis has been developed. The test is based on the measurement of 14CO2 produced by the oxidation of formate labeled with carbon-14. The test system uses 5 X 10(7) organisms in 1 ml of Middlebrook 7H9 medium plus albumin-dextrose-catalase enrichment and 1 muCi of [14C]formate. The 14CO2 produced is measured in an ionization chamber at 24-, 48-, and 72-hour intervals, with and without the addition of antituberculous drugs. Isoniazid, streptomycin, rifampin, and ethambutol were each tested at 3 concentrations by the radiometric method and the reference (agar dilution) method. Six standard strains and 21 patient isolates were compared by both methods. Production of 14CO2 was quantitatively decreased in the presence of drugs that inhibit the organism. The radiometric method requires 2 days; the agar dilution, 14 to 21 days.

  18. AIRS radiometric calibration validation for climate research

    NASA Technical Reports Server (NTRS)

    Aumann, Hartmut H.; Pagano, Thomas S.; Elliott, Denis; Gaiser, Steve; Gregorich, Dave; Broberg, Steve

    2005-01-01

    Climate research using data from satellite based radiometers makes extreme demands on the traceability and stability of the radiometric calibration. The selection of a cooled grating array spectrometer for the Atmospheric Infrared Sounder, AIRS, is key, but does not ensured that AIRS data will be of climate quality. Additional design features, plus additional pre-launch testing, and extensive on-orbit calibration subsystem monitoring beyond what would suffice for application of the data to weather forecasting were required to ensure the radiometric data quality required for climate research. Validation that climate data quality are being generated makes use of the sea surface skin temperatures (SST and (obs-calc).

  19. Wafer-level radiometric performance testing of uncooled microbolometer arrays

    NASA Astrophysics Data System (ADS)

    Dufour, Denis G.; Topart, Patrice; Tremblay, Bruno; Julien, Christian; Martin, Louis; Vachon, Carl

    2014-03-01

    A turn-key semi-automated test system was constructed to perform on-wafer testing of microbolometer arrays. The system allows for testing of several performance characteristics of ROIC-fabricated microbolometer arrays including NETD, SiTF, ROIC functionality, noise and matrix operability, both before and after microbolometer fabrication. The system accepts wafers up to 8 inches in diameter and performs automated wafer die mapping using a microscope camera. Once wafer mapping is completed, a custom-designed quick insertion 8-12 μm AR-coated Germanium viewport is placed and the chamber is pumped down to below 10-5 Torr, allowing for the evaluation of package-level focal plane array (FPA) performance. The probe card is electrically connected to an INO IRXCAM camera core, a versatile system that can be adapted to many types of ROICs using custom-built interface printed circuit boards (PCBs). We currently have the capability for testing 384x288, 35 μm pixel size and 160x120, 52 μm pixel size FPAs. For accurate NETD measurements, the system is designed to provide an F/1 view of two rail-mounted blackbodies seen through the Germanium window by the die under test. A master control computer automates the alignment of the probe card to the dies, the positioning of the blackbodies, FPA image frame acquisition using IRXCAM, as well as data analysis and storage. Radiometric measurement precision has been validated by packaging dies measured by the automated probing system and re-measuring the SiTF and Noise using INO's pre-existing benchtop system.

  20. Kernel MAD Algorithm for Relative Radiometric Normalization

    NASA Astrophysics Data System (ADS)

    Bai, Yang; Tang, Ping; Hu, Changmiao

    2016-06-01

    The multivariate alteration detection (MAD) algorithm is commonly used in relative radiometric normalization. This algorithm is based on linear canonical correlation analysis (CCA) which can analyze only linear relationships among bands. Therefore, we first introduce a new version of MAD in this study based on the established method known as kernel canonical correlation analysis (KCCA). The proposed method effectively extracts the non-linear and complex relationships among variables. We then conduct relative radiometric normalization experiments on both the linear CCA and KCCA version of the MAD algorithm with the use of Landsat-8 data of Beijing, China, and Gaofen-1(GF-1) data derived from South China. Finally, we analyze the difference between the two methods. Results show that the KCCA-based MAD can be satisfactorily applied to relative radiometric normalization, this algorithm can well describe the nonlinear relationship between multi-temporal images. This work is the first attempt to apply a KCCA-based MAD algorithm to relative radiometric normalization.

  1. Based on Narcissus of radiometric calibration technology

    NASA Astrophysics Data System (ADS)

    Jin, Libing; Tang, Shaofan; Liu, Jianfeng; Peng, Honggang

    2015-08-01

    Thermal radiation is an inherent property of all objects. Generally, it is believed that the body, which temperature is above absolute zero, can keep generating infrared radiation. Infrared remote sensing, using of satellite-borne or airborne sensors, collects infrared information to identify the surface feature and inversion of surface parameters, temperature, etc. In order to get more accurately feature information, quantitative measurement is required. Infrared radiometric calibration is one of the key technologies of quantitative infrared remote sensing. Most high-resolution thermal imaging systems are cooling. For the infrared optical system which is having a cooled detector, there are some special phenomenons. Since the temperature of the detector's photosensitive surface is generally low, which is very different from system temperature, it is a very strong cold radiation source. Narcissus refers to the case that the cooled detector can "see" its own reflecting image, which may affect the image quality of infrared system seriously. But for radiometric calibration of satellite-borne infrared camera, it can sometimes take advantage of the narcissus instead of cold cryogenic radiometric calibration. In this paper, the use of narcissus to carry out radiometric calibration is summarized, and simulation results show the feasibility.

  2. Radiometric Characterization of IKONOS Multispectral Imagery

    NASA Technical Reports Server (NTRS)

    Pagnutti, Mary; Ryan, Robert E.; Kelly, Michelle; Holekamp, Kara; Zanoni, Vicki; Thome, Kurtis; Schiller, Stephen

    2002-01-01

    A radiometric characterization of Space Imaging's IKONOS 4-m multispectral imagery has been performed by a NASA funded team from the John C. Stennis Space Center (SSC), the University of Arizona Remote Sensing Group (UARSG), and South Dakota State University (SDSU). Both intrinsic radiometry and the effects of Space Imaging processing on radiometry were investigated. Relative radiometry was examined with uniform Antarctic and Saharan sites. Absolute radiometric calibration was performed using reflectance-based vicarious calibration methods on several uniform sites imaged by IKONOS, coincident with ground-based surface and atmospheric measurements. Ground-based data and the IKONOS spectral response function served as input to radiative transfer codes to generate a Top-of-Atmosphere radiance estimate. Calibration coefficients derived from each vicarious calibration were combined to generate an IKONOS radiometric gain coefficient for each multispectral band assuming a linear response over the full dynamic range of the instrument. These calibration coefficients were made available to Space Imaging, which subsequently adopted them by updating its initial set of calibration coefficients. IKONOS imagery procured through the NASA Scientific Data Purchase program is processed with or without a Modulation Transfer Function Compensation kernel. The radiometric effects of this kernel on various scene types was also investigated. All imagery characterized was procured through the NASA Scientific Data Purchase program.

  3. Smartphone application for multi-phasic interventional trials in psychiatry: Technical design of an automated smart server.

    PubMed

    Zhang, Melvyn W B; Ho, Roger C M

    2016-12-13

    Smartphones and their accompanying applications are currently widely utilized in various healthcare interventions. Prior to the deployment of these tools for healthcare intervention, typically, proof of concept feasibility studies, as well as randomized trials are conducted to determine that these tools are efficacious prior to their actual implementation. In the field of psychiatry, most of the current interventions seek to compare smartphone based intervention against conventional care. There remains a paucity of research evaluating different forms of interventions using a single smartphone application. In the field of nutrition, there has been recent pioneering research demonstrating how a multi-phasic randomized controlled trial could be conducted using a single smartphone application. Despite the innovativeness of the previous smartphone conceptualization, there remains a paucity of technical information underlying the conceptualization that would support a multi-phasic interventional trial. It is thus the aim of the current technical note to share insights into an innovative server design that would enable the delivery of multi-phasic trials.

  4. Automating the Coupling of ORIGEN with GADRAS via the Fallout Analysis Tool for National Technical Nuclear Forensics

    SciTech Connect

    Monterial, Mateusz; Jodoin, Vincent J; Lefebvre, Jordan P; Peplow, Douglas E.; Hooper, David A

    2012-01-01

    Nuclear forensic teams will be deployed to collect and evaluate fallout samples on the ground in the scenario of a low-yield nuclear detonation in a heavily populated area. Quick non-destructive methods of predicting the quality of the sample before it is analyzed in detail are essential for efficient post-event collections. In this work, the process of exporting Defense Land Fallout Interpretive Code (DELFIC) results into Gamma Detector Response and Analysis Software (GADRAS) has been automated within the Fallout Analysis Tool. This coupling allows for the simulation of detector responses to fallout samples with varying degrees of fractionation. The degree to which the samples are fractionated depends on the location of the samples in the fallout field. In the following study, this phenomenon is examined, as its understanding is important to the investigation of debris distribution. The simulated detector spectra from GADRAS can be used to compare peak ratios of volatile-refractory isotope pairs in order to determine the degree of fractionation. Simulated fractionated fallout samples from DELFIC for a 10 kt, pure 235U fission surface burst were modeled for distances ranging to 256 km out from ground zero, and for times up to 1 week from detonation. The fractionation ratios, also known as r values, from isotope concentrations, photon lines and peak areas of four volatile-refractory pairs were calculated and compared. Fractionation prediction via the peak areas method was evaluated for each pair by comparing the results with the simulated radionuclide inventory.

  5. Infrared radiometric technique in temperature measurement

    NASA Technical Reports Server (NTRS)

    Glazer, S.; Madding, R.

    1988-01-01

    One class of commercially available imaging infrared radiometers using cooled detectors is sensitive to radiation over the 3 to 12 micron wavelength band. Spectral filters can tailor instrument sensitivity to specific regions where the target exhibits optimum radiance. The broadband spectral response coupled with real time two-dimensional imaging and emittance/background temperature corrections make the instruments useful for remote measurement of surface temperatures from -20 C to +1500 C. Commonly used radiometric techniques and assumptions are discussed, and performance specifications for a typical modern commercial instrument are presented. The potential usefulness of an imaging infrared radiometer in space laboratories is highlighted through examples of research, nondestructive evaluation, safety, and routine maintenance applications. Future improvements in instrument design and application of the radiometric technique are discussed.

  6. Geometric and Radiometric Evaluation of Rasat Images

    NASA Astrophysics Data System (ADS)

    Cam, Ali; Topan, Hüseyin; Oruç, Murat; Özendi, Mustafa; Bayık, Çağlar

    2016-06-01

    RASAT, the second remote sensing satellite of Turkey, was designed and assembled, and also is being operated by TÜBİTAK Uzay (Space) Technologies Research Institute (Ankara). RASAT images in various levels are available free-of-charge via Gezgin portal for Turkish citizens. In this paper, the images in panchromatic (7.5 m GSD) and RGB (15 m GSD) bands in various levels were investigated with respect to its geometric and radiometric characteristics. The first geometric analysis is the estimation of the effective GSD as less than 1 pixel for radiometrically processed level (L1R) of both panchromatic and RGB images. Secondly, 2D georeferencing accuracy is estimated by various non-physical transformation models (similarity, 2D affine, polynomial, affine projection, projective, DLT and GCP based RFM) reaching sub-pixel accuracy using minimum 39 and maximum 52 GCPs. The radiometric characteristics are also investigated for 8 bits, estimating SNR between 21.8-42.2, and noise 0.0-3.5 for panchromatic and MS images for L1R when the sea is masked to obtain the results for land areas. The analysis show that RASAT images satisfies requirements for various applications. The research is carried out in Zonguldak test site which is mountainous and partly covered by dense forest and urban areas.

  7. Radiometric age map of southwest Alaska

    USGS Publications Warehouse

    Wilson, Frederic H.; Turner, D.L.

    1975-01-01

    This map includes published, thesis, and open-file radiometric data available to us as of June, 1975. Some dates are not plotted because of inadequate location data in the original references.The map is divided into five sections, based on 1:1,000,000 scale enlargements of the National Atlas maps of Alaska. Within each section (e.g., southeastern Alaska), radiometric dates are plotted and keyed to 1:250,000 scale quadrangles. Accompanying each map section is table 1, listing map numbers and the sample identification numbers used in DGGS Special Report 10: Radiometric Dates from Alaska-A 1975 Compilation”. The reader is referred to Special Report 10 for more complete information on location, rock type, dating method, and literature references for each age entry. A listing of dates in Special Report lo which require correction or deletion is included S table 2. Corrected and additional entries are listed in table 3. The listings in tables 2 and 3 follow the format of Special Report 10. Table 4 is a glossary of abbreviations used for quadrangle name, rock type, mineral dated, and type of dating method used.

  8. Radiometric age map of southcentral Alaska

    USGS Publications Warehouse

    Wilson, Frederic H.; Turner, D.L.

    1975-01-01

    This map includes published, thesis, and open-file radiometric data available to us as of June, 1975. Some dates are not plotted because of inadequate location data in the original references.The map is divided into five sections, based on 1:1,000,000 scale enlargements of the National Atlas maps of Alaska. Within each section (e.g., southeastern Alaska), radiometric dates are plotted and keyed to 1:250,000 scale quadrangles. Accompanying each map section is table 1, listing map numbers and the sample identification numbers used in DGGS Special Report 10: Radiometric Dates from Alaska-A 1975 Compilation”. The reader is referred to Special Report 10 for more complete information on location, rock type, dating method, and literature references for each age entry. A listing of dates in Special Report lo which require correction or deletion is included S table 2. Corrected and additional entries are listed in table 3. The listings in tables 2 and 3 follow the format of Special Report 10. Table 4 is a glossary of abbreviations used for quadrangle name, rock type, mineral dated, and type of dating method used.

  9. Radiometric age map of northern Alaska

    USGS Publications Warehouse

    Wilson, Frederic H.; Turner, D.L.

    1975-01-01

    This map includes published, thesis, and open-file radiometric data available to us as of June, 1975. Some dates are not plotted because of inadequate location data in the original references.The map is divided into five sections, based on 1:1,000,000 scale enlargements of the National Atlas maps of Alaska. Within each section (e.g., southeastern Alaska), radiometric dates are plotted and keyed to 1:250,000 scale quadrangles. Accompanying each map section is table 1, listing map numbers and the sample identification numbers used in DGGS Special Report 10: Radiometric Dates from Alaska-A 1975 Compilation”. The reader is referred to Special Report 10 for more complete information on location, rock type, dating method, and literature references for each age entry. A listing of dates in Special Report lo which require correction or deletion is included S table 2. Corrected and additional entries are listed in table 3. The listings in tables 2 and 3 follow the format of Special Report 10. Table 4 is a glossary of abbreviations used for quadrangle name, rock type, mineral dated, and type of dating method used.

  10. Radiometric age map of Aleutian Islands

    USGS Publications Warehouse

    Wilson, Frederic H.; Turner, D.L.

    1975-01-01

    This map includes published, thesis, and open-file radiometric data available to us as of June, 1975. Some dates are not plotted because of inadequate location data in the original references.The map is divided into five sections, based on 1:1,000,000 scale enlargements of the National Atlas maps of Alaska. Within each section (e.g., southeastern Alaska), radiometric dates are plotted and keyed to 1:250,000 scale quadrangles. Accompanying each map section is table 1, listing map numbers and the sample identification numbers used in DGGS Special Report 10: Radiometric Dates from Alaska-A 1975 Compilation”. The reader is referred to Special Report 10 for more complete information on location, rock type, dating method, and literature references for each age entry. A listing of dates in Special Report lo which require correction or deletion is included S table 2. Corrected and additional entries are listed in table 3. The listings in tables 2 and 3 follow the format of Special Report 10. Table 4 is a glossary of abbreviations used for quadrangle name, rock type, mineral dated, and type of dating method used.

  11. Radiometric age map of southeast Alaska

    USGS Publications Warehouse

    Wilson, Frederic H.; Turner, D.L.

    1975-01-01

    This map includes published, thesis, and open-file radiometric data available to us as of June, 1975. Some dates are not plotted because of inadequate location data in the original references.The map is divided into five sections, based on 1:1,000,000 scale enlargements of the National Atlas maps of Alaska. Within each section (e.g., southeastern Alaska), radiometric dates are plotted and keyed to 1:250,000 scale quadrangles. Accompanying each map section is table 1, listing map numbers and the sample identification numbers used in DGGS Special Report 10: Radiometric Dates from Alaska-A 1975 Compilation”. The reader is referred to Special Report 10 for more complete information on location, rock type, dating method, and literature references for each age entry. A listing of dates in Special Report lo which require correction or deletion is included S table 2. Corrected and additional entries are listed in table 3. The listings in tables 2 and 3 follow the format of Special Report 10. Table 4 is a glossary of abbreviations used for quadrangle name, rock type, mineral dated, and type of dating method used.

  12. Revised landsat-5 thematic mapper radiometric calibration

    USGS Publications Warehouse

    Chander, G.; Markham, B.L.; Barsi, J.A.

    2007-01-01

    Effective April 2, 2007, the radiometric calibration of Landsat-5 (L5) Thematic Mapper (TM) data that are processed and distributed by the U.S. Geological Survey (USGS) Center for Earth Resources Observation and Science (EROS) will be updated. The lifetime gain model that was implemented on May 5, 2003, for the reflective bands (1-5, 7) will be replaced by a new lifetime radiometric-calibration curve that is derived from the instrument's response to pseudoinvariant desert sites and from cross calibration with the Landsat-7 (L7) Enhanced TM Plus (ETM+). Although this calibration update applies to all archived and future L5 TM data, the principal improvements in the calibration are for the data acquired during the first eight years of the mission (1984-1991), where the changes in the instrument-gain values are as much as 15%. The radiometric scaling coefficients for bands 1 and 2 for approximately the first eight years of the mission have also been changed. Users will need to apply these new coefficients to convert the calibrated data product digital numbers to radiance. The scaling coefficients for the other bands have not changed.

  13. The radiometric characteristics of KOMPSAT-3A by using reference radiometric tarps and ground measurement

    NASA Astrophysics Data System (ADS)

    Yeom, Jong-Min

    2016-09-01

    In this study, we performed the vicarious radiometric calibration of KOMPSAT-3A multispectral bands by using 6S radiative transfer model, radiometric tarps, MFRSR measurements. Furthermore, to prepare the accurate input parameter, we also did experiment work to measure the BRDF of radiometric tarps based on hyperspectral gonioradiometer to compensate the observation geometry difference between satellite and ASD Fieldspec 3. Also, we measured point spread function (PSF) by using the bright star and corrected multispectral bands based on the Wiener filter. For accurate atmospheric constituent effects such as aerosol optical depth, column water, and total ozone, we used MFRSR instrument and estimated related optical depth of each gases. Based on input parameters for 6S radiative transfer model, we simulated top of atmosphere (TOA) radiance by observed by KOMPSAT-3A and matched-up the digital number. Consequently, DN to radiance coefficients was determined based on aforementioned methods and showed reasonable statistics results.

  14. Radiometric measurement of differential metabolism of fatty acids by Mycobacterium lepraemurium.

    PubMed

    Camargo, E E; Kertcher, J A; Larson, S M; Tepper, B S; Wagner, H N

    1979-06-01

    An assay system has been developed based on automated radiometric quantification of 14CO2 produced through oxidation of (1--14C) fatty acids by mycobacteria. With this system, the Hawaiian strain of M. lepraemurium was studied using the K-36 buffer as a suspending solution for the organisms along with 5.0 muCi of one of the following fatty acids: acetate, butyric, hexanoic, octanoic, decanoic, lauric, myristic, palmitic, stearic, oleic, linoleic, linolenic, and malonic. The 14CO2 production by this organism was greatest with lauric, decanoic, myristic, octanoic, stearic, oleic, linoleic, linolenic, and malonic. The 14CO2 production by this organism was greatest with lauric, decanoic, myristic, octanoic, and stearic acids, in decreasing order. Assimilation studies and radiochromatograms confirmed that most of the oxidized substrates were converted into by-products with no change in those from which no oxidation was found. These data suggest that the radiometric measurement of differential fatty acid metabolism may provide a basis of radiometric identification of M. lepraemurium and assessment of the growth requirements of this organism.

  15. Relative radiometric calibration of LANDSAT TM reflective bands

    NASA Technical Reports Server (NTRS)

    Barker, J. L.

    1984-01-01

    Raw thematic mapper (TM) calibration data from pre-launch tests and in-orbit acquisitions from LANDSAT 4 and 5 satellites are analyzed to assess the radiometric characteristics of the TM sensor. A software program called TM radiometric and algorithmic performance program (TRAPP) was used for the majority of analyses. Radiometric uncertainty in the final TM image originates from: (1) scene variability (solar irradiance and atmospheric scattering); (2) optical and electrical variability of the sensor; and (3) variability introduced during image processing.

  16. Evaluation on Radiometric Capability of Chinese Optical Satellite Sensors

    PubMed Central

    Yang, Aixia; Zhong, Bo; Wu, Shanlong; Liu, Qinhuo

    2017-01-01

    The radiometric capability of on-orbit sensors should be updated on time due to changes induced by space environmental factors and instrument aging. Some sensors, such as Moderate Resolution Imaging Spectroradiometer (MODIS), have onboard calibrators, which enable real-time calibration. However, most Chinese remote sensing satellite sensors lack onboard calibrators. Their radiometric calibrations have been updated once a year based on a vicarious calibration procedure, which has affected the applications of the data. Therefore, a full evaluation of the sensors’ radiometric capabilities is essential before quantitative applications can be made. In this study, a comprehensive procedure for evaluating the radiometric capability of several Chinese optical satellite sensors is proposed. In this procedure, long-term radiometric stability and radiometric accuracy are the two major indicators for radiometric evaluation. The radiometric temporal stability is analyzed by the tendency of long-term top-of-atmosphere (TOA) reflectance variation; the radiometric accuracy is determined by comparison with the TOA reflectance from MODIS after spectrally matching. Three Chinese sensors including the Charge-Coupled Device (CCD) camera onboard Huan Jing 1 satellite (HJ-1), as well as the Visible and Infrared Radiometer (VIRR) and Medium-Resolution Spectral Imager (MERSI) onboard the Feng Yun 3 satellite (FY-3) are evaluated in reflective bands based on this procedure. The results are reasonable, and thus can provide reliable reference for the sensors’ application, and as such will promote the development of Chinese satellite data. PMID:28117745

  17. Evaluation on Radiometric Capability of Chinese Optical Satellite Sensors.

    PubMed

    Yang, Aixia; Zhong, Bo; Wu, Shanlong; Liu, Qinhuo

    2017-01-22

    The radiometric capability of on-orbit sensors should be updated on time due to changes induced by space environmental factors and instrument aging. Some sensors, such as Moderate Resolution Imaging Spectroradiometer (MODIS), have onboard calibrators, which enable real-time calibration. However, most Chinese remote sensing satellite sensors lack onboard calibrators. Their radiometric calibrations have been updated once a year based on a vicarious calibration procedure, which has affected the applications of the data. Therefore, a full evaluation of the sensors' radiometric capabilities is essential before quantitative applications can be made. In this study, a comprehensive procedure for evaluating the radiometric capability of several Chinese optical satellite sensors is proposed. In this procedure, long-term radiometric stability and radiometric accuracy are the two major indicators for radiometric evaluation. The radiometric temporal stability is analyzed by the tendency of long-term top-of-atmosphere (TOA) reflectance variation; the radiometric accuracy is determined by comparison with the TOA reflectance from MODIS after spectrally matching. Three Chinese sensors including the Charge-Coupled Device (CCD) camera onboard Huan Jing 1 satellite (HJ-1), as well as the Visible and Infrared Radiometer (VIRR) and Medium-Resolution Spectral Imager (MERSI) onboard the Feng Yun 3 satellite (FY-3) are evaluated in reflective bands based on this procedure. The results are reasonable, and thus can provide reliable reference for the sensors' application, and as such will promote the development of Chinese satellite data.

  18. Absolute Radiometric Calibration of KOMPSAT-3A

    NASA Astrophysics Data System (ADS)

    Ahn, H. Y.; Shin, D. Y.; Kim, J. S.; Seo, D. C.; Choi, C. U.

    2016-06-01

    This paper presents a vicarious radiometric calibration of the Korea Multi-Purpose Satellite-3A (KOMPSAT-3A) performed by the Korea Aerospace Research Institute (KARI) and the Pukyong National University Remote Sensing Group (PKNU RSG) in 2015.The primary stages of this study are summarized as follows: (1) A field campaign to determine radiometric calibrated target fields was undertaken in Mongolia and South Korea. Surface reflectance data obtained in the campaign were input to a radiative transfer code that predicted at-sensor radiance. Through this process, equations and parameters were derived for the KOMPSAT-3A sensor to enable the conversion of calibrated DN to physical units, such as at-sensor radiance or TOA reflectance. (2) To validate the absolute calibration coefficients for the KOMPSAT-3A sensor, we performed a radiometric validation with a comparison of KOMPSAT-3A and Landsat-8 TOA reflectance using one of the six PICS (Libya 4). Correlations between top-of-atmosphere (TOA) radiances and the spectral band responses of the KOMPSAT-3A sensors at the Zuunmod, Mongolia and Goheung, South Korea sites were significant for multispectral bands. The average difference in TOA reflectance between KOMPSAT-3A and Landsat-8 image over the Libya 4, Libya site in the red-green-blue (RGB) region was under 3%, whereas in the NIR band, the TOA reflectance of KOMPSAT-3A was lower than the that of Landsat-8 due to the difference in the band passes of two sensors. The KOMPSAT-3Aensor includes a band pass near 940 nm that can be strongly absorbed by water vapor and therefore displayed low reflectance. Toovercome this, we need to undertake a detailed analysis using rescale methods, such as the spectral bandwidth adjustment factor.

  19. Optical Imaging and Radiometric Modeling and Simulation

    NASA Technical Reports Server (NTRS)

    Ha, Kong Q.; Fitzmaurice, Michael W.; Moiser, Gary E.; Howard, Joseph M.; Le, Chi M.

    2010-01-01

    OPTOOL software is a general-purpose optical systems analysis tool that was developed to offer a solution to problems associated with computational programs written for the James Webb Space Telescope optical system. It integrates existing routines into coherent processes, and provides a structure with reusable capabilities that allow additional processes to be quickly developed and integrated. It has an extensive graphical user interface, which makes the tool more intuitive and friendly. OPTOOL is implemented using MATLAB with a Fourier optics-based approach for point spread function (PSF) calculations. It features parametric and Monte Carlo simulation capabilities, and uses a direct integration calculation to permit high spatial sampling of the PSF. Exit pupil optical path difference (OPD) maps can be generated using combinations of Zernike polynomials or shaped power spectral densities. The graphical user interface allows rapid creation of arbitrary pupil geometries, and entry of all other modeling parameters to support basic imaging and radiometric analyses. OPTOOL provides the capability to generate wavefront-error (WFE) maps for arbitrary grid sizes. These maps are 2D arrays containing digital sampled versions of functions ranging from Zernike polynomials to combination of sinusoidal wave functions in 2D, to functions generated from a spatial frequency power spectral distribution (PSD). It also can generate optical transfer functions (OTFs), which are incorporated into the PSF calculation. The user can specify radiometrics for the target and sky background, and key performance parameters for the instrument s focal plane array (FPA). This radiometric and detector model setup is fairly extensive, and includes parameters such as zodiacal background, thermal emission noise, read noise, and dark current. The setup also includes target spectral energy distribution as a function of wavelength for polychromatic sources, detector pixel size, and the FPA s charge

  20. A comparison of four relative radiometric normalization (RRN) techniques for mosaicing H-res multi-temporal thermal infrared (TIR) flight-lines of a complex urban scene

    NASA Astrophysics Data System (ADS)

    Rahman, M. M.; Hay, G. J.; Couloigner, I.; Hemachandran, B.; Bailin, J.

    2015-08-01

    High-spatial and -radiometric resolution (H-res) thermal infrared (TIR) airborne imagery, such as the TABI-1800 (Thermal Airborne Broadband Imager) provide unique surface temperature information that can be used for urban heat loss mapping, heat island analysis, and landcover classifications. For mapping large urban areas at a high-spatial resolution (i.e., sub-meter), airborne thermal imagery needs to be acquired over a number of flight-lines and mosaiced together. However, due to radiometric variations between flight-lines the similar objects tend to have different temperature characteristics on the mosaicked image, resulting in reduced visual and radiometric agreement between the flight-lines composing the final mosaiced output. To reduce radiometric variability between airborne TIR flight-lines, with a view to produce a visually seamless TIR image mosaic, we evaluate four relative radiometric normalization techniques including: (i) Histogram Matching, (ii) Pseudo Invariant Feature (PIF) Based Linear Regression, (iii) PIF-Based Theil-Sen Regression, and (iv) No-Change Stratified Random Samples (NCSRS) Based Linear Regression. The techniques are evaluated on two adjacent TABI-1800 airborne flight-lines (each ˜30 km × 0.9 km) collected ˜25 min apart over a portion of The City of Calgary (with ˜30% overlap between them). The performances of these techniques are compared based on four criteria: (i) speed of computation, (ii) ability to automate, (iii) visual assessment, and (iv) statistical analysis. Results show that NCSRS-Based Linear Regression produces the best overall results closely followed by Histogram Matching. Specifically, these two radiometric normalization techniques: (i) increase the visual and statistical agreement between the tested TIR airborne flight-lines (NCSRS Based Linear Regression increases radiometric agreement between flight-lines by 53.3% and Histogram Matching by 52.4%), (ii) produce a visually seamless image mosaic, and (iii) can be

  1. Systematic biases in radiometric diameter determinations

    NASA Technical Reports Server (NTRS)

    Spencer, John R.; Lebofsky, Larry A.; Sykes, Mark V.

    1989-01-01

    Radiometric diameter determinations are presently shown to often be significantly affected by the effect of rotation. This thermal effect of rotation depends not only on the object's thermal inertia, rotation rate, and pole orientation, but also on its temperature, since colder objects having constant rotation rate and thermal inertia will radiate less of their heat on the diurnal than on the nocturnal hemisphere. A disk-integrated beaming parameter of 0.72 is determined for the moon, and used to correct empirically for the roughness effects in thermophysical models; the standard thermal model is found to systematically underestimate cold object diameters, while overstating their albedos.

  2. Radiometric dates from Alaska: A 1975 compilation

    USGS Publications Warehouse

    Turner, D.L.; Grybeck, Donald; Wilson, Frederic H.

    1975-01-01

    The following table of radiometric dates from Alaska includes published material through 1972 as well as some selected later data. The table includes 726 mineral and whole-rock dates determined by the K-Ar, Rb-Sr, fission-track U-Pb, and Pb-alpha techniques.The data are organized in alphabetical order of the 1:250,000 scale quadrangles in which the dated rocks are located. The latitude and longitude of each sample are given. In addition, each sample is located on a 1:250,000 quadrangle map by a grid system. The initial point of the grid is taken as the southwest corner of the quadrangle and the location of the sample is measured in inches east and inches north from that corner, e.g., "156E 126N" indicated 15.6 inches east and 12.6 inches north of the southwest corner of the quadrangle. Zeroes in the location columns for some dates indicate that accurate locations are not available.Rock type, dating method, mineral dated, radiometric age, sample identification number, and reference are also listed where possible. Short comments, mostly geographic locality names, are given for some dates. These comments have been taken from the original references.Sample identification numbers beginning with "AA" or "BB" have been assigned arbitrarily in cases where sample numbers were not assigned in the original references. Abbreviations are explained in the appendix at the end of table 1.

  3. Photovoltaic radiometric measurements workshop introduction and overview

    SciTech Connect

    Myers, D.R.

    1995-09-01

    The National Renewable Energy Laboratory supports the U.S. Department of Energy`s photovoltaic (PV) program through research in basic and engineering sciences related to improving the performance and commercial viability of PV energy conversion as an alternative energy source. Since 1975, much progress and technological evolution has taken place, chronicled in part by periodic scientific and engineering conferences, program reviews, and workshops involving manufacturers, universities, and private and government research laboratories. The growth of the PV program resulted in more specialized and topical workshops sponsored in part by the NREL Photovoltaic Module and Systems Performance and Engineering Project to address specific program issues. Solar and optical radiometric measurements and data are crucial in quantifying PV research progress, available solar resources, and predicted and installed PV array performance. This workshop is an effort to focus on the state-of-the-art, needs, future research directions, and NREL action items for radiometric instrumentation, data, and research to maintain the momentum of progress toward the fundamental understanding of, improvement in, and sustainability of PV technology as an alternative energy source.

  4. Real-time adaptive radiometric compensation.

    PubMed

    Grundhöfer, Anselm; Bimber, Oliver

    2008-01-01

    Recent radiometric compensation techniques make it possible to project images onto colored and textured surfaces. This is realized with projector-camera systems by scanning the projection surface on a per-pixel basis. Using the captured information, a compensation image is calculated that neutralizes geometric distortions and color blending caused by the underlying surface. As a result, the brightness and the contrast of the input image is reduced compared to a conventional projection onto a white canvas. If the input image is not manipulated in its intensities, the compensation image can contain values that are outside the dynamic range of the projector. These will lead to clipping errors and to visible artifacts on the surface. In this article, we present an innovative algorithm that dynamically adjusts the content of the input images before radiometric compensation is carried out. This reduces the perceived visual artifacts while simultaneously preserving a maximum of luminance and contrast. The algorithm is implemented entirely on the GPU and is the first of its kind to run in real-time.

  5. Landsat-7 ETM+ radiometric calibration status

    NASA Astrophysics Data System (ADS)

    Barsi, Julia A.; Markham, Brian L.; Czapla-Myers, Jeffrey S.; Helder, Dennis L.; Hook, Simon J.; Schott, John R.; Haque, Md. Obaidul

    2016-09-01

    Now in its 17th year of operation, the Enhanced Thematic Mapper + (ETM+), on board the Landsat-7 satellite, continues to systematically acquire imagery of the Earth to add to the 40+ year archive of Landsat data. Characterization of the ETM+ on-orbit radiometric performance has been on-going since its launch in 1999. The radiometric calibration of the reflective bands is still monitored using on-board calibration devices, though the Pseudo-Invariant Calibration Sites (PICS) method has proven to be an effective tool as well. The calibration gains were updated in April 2013 based primarily on PICS results, which corrected for a change of as much as -0.2%/year degradation in the worst case bands. A new comparison with the SADE database of PICS results indicates no additional degradation in the updated calibration. PICS data are still being tracked though the recent trends are not well understood. The thermal band calibration was updated last in October 2013 based on a continued calibration effort by NASA/Jet Propulsion Lab and Rochester Institute of Technology. The update accounted for a 0.036 W/m2 sr μm or 0.26K at 300K bias error. The updated lifetime trend is now stable to within +/- 0.4K.

  6. Understanding Satellite Characterization Knowledge Gained from Radiometric Data

    DTIC Science & Technology

    2011-09-01

    UNDERSTANDING SATELLITE CHARACTERIZATION KNOWLEDGE GAINED FROM RADIOMETRIC DATA Andrew Harms Princeton University Kris Hamada, Charles J. Wetterer...framework for determining satellite characterization knowledge, in the form of estimated parameter uncertainties, from radiometric observation type...uncer- tainties into satellite characterization parameter space. These parameters can include size, shape, orientation, material properties, etc., and

  7. Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurements

    DTIC Science & Technology

    2015-03-31

    Final March 2013 -- February 2015 Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurements N00014-13-1-0352 Yue, Dick K.P... Dick K.P. and Yuming Liu 617-253-6823; 617-252-1647 1 Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurements Dick K.P

  8. Relative radiometric calibration of LANDSAT TM reflective bands

    NASA Technical Reports Server (NTRS)

    Barker, J. L.

    1984-01-01

    A common scientific methodology and terminology is outlined for characterizing the radiometry of both TM sensors. The magnitude of the most significant sources of radiometric variability are discussed and methods are recommended for achieving the exceptional potential inherent in the radiometric precision and accuracy of the TM sensors.

  9. Best practices for radiometric modeling of imaging spectrometers

    NASA Astrophysics Data System (ADS)

    Zellinger, Lou; Silny, John F.

    2015-09-01

    This paper provides best practices for the radiometric performance modeling of imaging spectrometers. A set of standard terminology is proposed to use when modeling imaging spectrometers. The calculation of various radiometric sensitivity metrics and their contrast counterparts are outlined. Modeling approaches are described for both solar reflected and thermally emitted bands. Finally, this approach is applied to an example hyperspectral sensor.

  10. Validation of Landsat 7 ETM+ band 6 radiometric performance

    NASA Technical Reports Server (NTRS)

    Palluconi, Frank; Hook, Simon; Abtahi, Ali; Alley, Ron

    2005-01-01

    Since shortly after launch the radiometric performance of band 6 of the ETM+ instrument on Landsat 7 has been evaluated using vicarious calbiration techniques for both land and water targets. This evaluation indicates the radiometric performance of band 6 has been both highly stable and accurate.

  11. Thematic mapper: detailed radiometric and geometric characteristics

    USGS Publications Warehouse

    Kieffer, Hugh

    1983-01-01

    Those radiometric characteristics of the Landsat 4 Thematic Mapper (TM) that can be established without absolute calibration of spectral data have been examined. Subscenes of radiometric all raw data (B-data) were examined on an individual detector basis: areas of uniform radiance were used to characterize subtle radiometric differences and noise problems. A variety of anomalies have been discovered with magnitude of a few digital levels or less: the only problem not addressable by ground processing is irregular width of the digital levels. Essentially all of this non-ideal performance is incorporated in the fully processed (P-type) images, but disguised by the geometric resampling procedure. The overall performance of the Thematic Mapper is a great improvement over previous Landsat scanners. The effective resolution in radiance is degraded by about a factor of two by irregular width of the digital levels. Several detectors have a change of gain with a period of several scans, the largest effect is about 4%. These detectors appear to switch between two response levels during scan direction reversal; there is no apparent periodicity to these changes. This can cause small apparent difference between forward and reverse scans for portions of an image. The high-frequency noise level of each detector was characterized by the standard deviation of the first derivative in the sample direction across a flat field. Coherent sinusoidal noise patterns were determined using one-dimensional Fourier transforms. A "stitching" pattern in Band 1 has a period of 13.8 samples with a peak-to-peak amplitude ranging from 1 to 5 DN. Noise with a period of 3.24 samples is pronounced for most detectors in band 1, to a lesser extent in bands 2, 3, and 4, and below background noise levels in bands 5, 6, and 7. The geometric fidelity of the GSFC film writer used for Thematic Mapper (TM) images was assessed by measurement with accuracy bette than three micrometers of a test grid. A set of 55

  12. Visible/infrared radiometric calibration station

    SciTech Connect

    Byrd, D.A.; Maier, W.B. II; Bender, S.C.; Holland, R.F.; Michaud, F.D.; Luettgen, A.L.; Christensen, R.W.; O`Brian, T.R.

    1994-07-01

    We have begun construction of a visible/infrared radiometric calibration station that will allow for absolute calibration of optical and IR remote sensing instruments with clear apertures less than 16 inches in diameter in a vacuum environment. The calibration station broadband sources will be calibrated at the National Institute of Standards and Technology (NIST) and allow for traceable absolute radiometric calibration to within {plus_minus}3% in the visible and near IR (0.4--2.5 {mu}m), and less than {plus_minus}1% in the infrared, up to 12 {mu}m. Capabilities for placing diffraction limited images or for sensor full-field flooding will exist. The facility will also include the calibration of polarization and spectral effects, spatial resolution, field of view performance, and wavefront characterization. The configuration of the vacuum calibration station consists of an off-axis 21 inch, f/3.2, parabolic collimator with a scanning fold flat in collimated space. The sources are placed, via mechanisms to be described, at the focal plane of the off-axis parabola. Vacuum system pressure will be in the 10{sup {minus}6} Torr range. The broadband white-light source is a custom design by LANL with guidance from Labsphere Inc. The continuous operating radiance of the integrating sphere will be from 0.0--0.006 W/cm{sup 2}/Sr/{mu}m (upper level quoted for {approximately}500 nm wavelength). The blackbody source is also custom designed at LANL with guidance from NIST. The blackbody temperature will be controllable between 250--350{degrees}K. Both of the above sources have 4.1 inch apertures with estimated radiometric instability at less than 1%. The designs of each of these units will be described. The monochromator and interferometer light sources are outside the vacuum, but all optical relay and beam shaping optics are enclosed within the vacuum calibration station. These sources are described, as well as the methodology for alignment and characterization.

  13. Radiometrically accurate FTS for atmospheric emission observations

    NASA Technical Reports Server (NTRS)

    Revercomb, H. E.; Smith, W. L.; Stromovsky, L. A.; Knuteson, R. O.; Buijs, H.

    1989-01-01

    The calibration and operational performance of an FTIR-based airborne high-resolution interferometer sounder (HIS) for use in broadband measurements of atmospheric emission at 3.8-16.6 microns are described. The radiometric and wavelength calibration procedures in the laboratory involved the use of reference black bodies at 300 and 245 K and the known wavelength of the HIS HeNe laser (corrected for FOV effects), respectively. The atmospheric verification program included downlooking observations from the NASA U2/ER2 aircraft (where resolving power of 1800-3800 was demonstrated) and uplooking observations from the ground; good agreement with data from balloon-borne radiosondes is obtained, with absolute temperature uncertainties of less than 0.5 K and reproducibilities of 0.1-0.2 K over most of the measurement domain.

  14. A Radiometric Uncertainty Tool for OLCI

    NASA Astrophysics Data System (ADS)

    Hunt, S.; Nieke, J.

    2016-08-01

    With its first satellite launched in February 2016, the Sentinel-3 mission will support Ocean, Land, Atmospheric, Emergency, Security and Cryospheric applications and related Copernicus services (http://www.copernicus.eu). One of the key payloads carried by the satellite, OLCI (Ocean and Land Colour Instrument), is a push-broom imaging spectrometer designed to image the Earth's surface in 21 spectral bands, from the visible to the near infrared, across a 1200 km swath. An understanding of the quality of the Level 1b (L1) data produced by OLCI is important for many of its applications. As such, work has been ongoing to develop a software tool to determine the per pixel uncertainty of these images to be used by L1 product users. This tool has been named OLCI-RUT (OLCI - Radiometric Uncertainty Tool) and this report provides a description of its development.

  15. GIFTS SM EDU Radiometric and Spectral Calibrations

    NASA Technical Reports Server (NTRS)

    Tian, J.; Reisse, R. a.; Johnson, D. G.; Gazarik, J. J.

    2007-01-01

    The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Sensor Module (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiance using a Fourier transform spectrometer (FTS). The GIFTS instrument gathers measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes the processing algorithms involved in the calibration. The calibration procedures can be subdivided into three categories: the pre-calibration stage, the calibration stage, and finally, the post-calibration stage. Detailed derivations for each stage are presented in this paper.

  16. TECHNICAL NOTE: Effect of bait delivery interval in an automated head-chamber system on respiration gas estimates when cattle are grazing rangeland

    USDA-ARS?s Scientific Manuscript database

    Agricultural methane emissions account for approximately 43% of all anthropogenic methane emissions and the majority of agricultural CH4 emissions are attributed to enteric fermentation within ruminant livestock, therefor interest is heightened in quantifying and mitigating this source. An automate...

  17. Precision radiometric surface temperature (PRST) sensor

    NASA Astrophysics Data System (ADS)

    Daly, James T.; Roberts, Carson; Bodkin, Andrew; Sundberg, Robert; Beaven, Scott; Weinheimer, Jeffrey

    2013-05-01

    There is a need for a Precision Radiometric Surface Temperature (PRST) measurement capability that can achieve noncontact profiling of a sample's surface temperature when heated dynamically during laser processing, aerothermal heating or metal cutting/machining. Target surface temperature maps within and near the heated spot provide critical quantitative diagnostic data for laser-target coupling effectiveness and laser damage assessment. In the case of metal cutting, this type of measurement provides information on plastic deformation in the primary shear zone where the cutting tool is in contact with the workpiece. The challenge in these cases is to measure the temperature of a target while its surface's temperature and emissivity are changing rapidly and with incomplete knowledge of how the emissivity and surface texture (scattering) changes with temperature. Bodkin Design and Engineering, LLC (BDandE), with partners Spectral Sciences, Inc. (SSI) and Space Computer Corporation (SCC), has developed a PRST Sensor that is based on a hyperspectral MWIR imager spanning the wavelength range 2-5 μm and providing a hyperspectral datacube of 20-24 wavelengths at 60 Hz frame rate or faster. This imager is integrated with software and algorithms to extract surface temperature from radiometric measurements over the range from ambient to 2000K with a precision of 20K, even without a priori knowledge of the target's emissivity and even as the target emissivity may be changing with time and temperature. In this paper, we will present a description of the PRST system as well as laser heating test results which show the PRST system mapping target surface temperatures in the range 600-2600K on a variety of materials.

  18. Absolute Radiometric Calibration of EUNIS-06

    NASA Technical Reports Server (NTRS)

    Thomas, R. J.; Rabin, D. M.; Kent, B. J.; Paustian, W.

    2007-01-01

    The Extreme-Ultraviolet Normal-Incidence Spectrometer (EUNIS) is a soundingrocket payload that obtains imaged high-resolution spectra of individual solar features, providing information about the Sun's corona and upper transition region. Shortly after its successful initial flight last year, a complete end-to-end calibration was carried out to determine the instrument's absolute radiometric response over its Longwave bandpass of 300 - 370A. The measurements were done at the Rutherford-Appleton Laboratory (RAL) in England, using the same vacuum facility and EUV radiation source used in the pre-flight calibrations of both SOHO/CDS and Hinode/EIS, as well as in three post-flight calibrations of our SERTS sounding rocket payload, the precursor to EUNIS. The unique radiation source provided by the Physikalisch-Technische Bundesanstalt (PTB) had been calibrated to an absolute accuracy of 7% (l-sigma) at 12 wavelengths covering our bandpass directly against the Berlin electron storage ring BESSY, which is itself a primary radiometric source standard. Scans of the EUNIS aperture were made to determine the instrument's absolute spectral sensitivity to +- 25%, considering all sources of error, and demonstrate that EUNIS-06 was the most sensitive solar E W spectrometer yet flown. The results will be matched against prior calibrations which relied on combining measurements of individual optical components, and on comparisons with theoretically predicted 'insensitive' line ratios. Coordinated observations were made during the EUNIS-06 flight by SOHO/CDS and EIT that will allow re-calibrations of those instruments as well. In addition, future EUNIS flights will provide similar calibration updates for TRACE, Hinode/EIS, and STEREO/SECCHI/EUVI.

  19. Radiometric consistency assessment of hyperspectral infrared sounders

    NASA Astrophysics Data System (ADS)

    Wang, L.; Han, Y.; Jin, X.; Chen, Y.; Tremblay, D. A.

    2015-07-01

    The radiometric and spectral consistency among the Atmospheric Infrared Sounder (AIRS), the Infrared Atmospheric Sounding Interferometer (IASI), and the Cross-track Infrared Sounder (CrIS) is fundamental for the creation of long-term infrared (IR) hyperspectral radiance benchmark datasets for both inter-calibration and climate-related studies. In this study, the CrIS radiance measurements on Suomi National Polar-orbiting Partnership (SNPP) satellite are directly compared with IASI on MetOp-A and -B at the finest spectral scale and with AIRS on Aqua in 25 selected spectral regions through one year of simultaneous nadir overpass (SNO) observations to evaluate radiometric consistency of these four hyperspectral IR sounders. The spectra from different sounders are paired together through strict spatial and temporal collocation. The uniform scenes are selected by examining the collocated Visible Infrared Imaging Radiometer Suite (VIIRS) pixels. Their brightness temperature (BT) differences are then calculated by converting the spectra onto common spectral grids. The results indicate that CrIS agrees well with IASI on MetOp-A and IASI on MetOp-B at the longwave IR (LWIR) and middle-wave IR (MWIR) bands with 0.1-0.2 K differences. There are no apparent scene-dependent patterns for BT differences between CrIS and IASI for individual spectral channels. CrIS and AIRS are compared at the 25 spectral regions for both Polar and Tropical SNOs. The combined global SNO datasets indicate that, the CrIS-AIRS BT differences are less than or around 0.1 K among 21 of 25 comparison spectral regions and they range from 0.15 to 0.21 K in the remaining 4 spectral regions. CrIS-AIRS BT differences in some comparison spectral regions show weak scene-dependent features.

  20. Radiometric consistency assessment of hyperspectral infrared sounders

    NASA Astrophysics Data System (ADS)

    Wang, L.; Han, Y.; Jin, X.; Chen, Y.; Tremblay, D. A.

    2015-11-01

    The radiometric and spectral consistency among the Atmospheric Infrared Sounder (AIRS), the Infrared Atmospheric Sounding Interferometer (IASI), and the Cross-track Infrared Sounder (CrIS) is fundamental for the creation of long-term infrared (IR) hyperspectral radiance benchmark data sets for both intercalibration and climate-related studies. In this study, the CrIS radiance measurements on Suomi National Polar-orbiting Partnership (SNPP) satellite are directly compared with IASI on MetOp-A and MetOp-B at the finest spectral scale and with AIRS on Aqua in 25 selected spectral regions through simultaneous nadir overpass (SNO) observations in 2013, to evaluate radiometric consistency of these four hyperspectral IR sounders. The spectra from different sounders are paired together through strict spatial and temporal collocation. The uniform scenes are selected by examining the collocated Visible Infrared Imaging Radiometer Suite (VIIRS) pixels. Their brightness temperature (BT) differences are then calculated by converting the spectra onto common spectral grids. The results indicate that CrIS agrees well with IASI on MetOp-A and IASI on MetOp-B at the long-wave IR (LWIR) and middle-wave IR (MWIR) bands with 0.1-0.2 K differences. There are no apparent scene-dependent patterns for BT differences between CrIS and IASI for individual spectral channels. CrIS and AIRS are compared at the 25 spectral regions for both polar and tropical SNOs. The combined global SNO data sets indicate that the CrIS-AIRS BT differences are less than or around 0.1 K among 21 of 25 spectral regions and they range from 0.15 to 0.21 K in the remaining four spectral regions. CrIS-AIRS BT differences in some comparison spectral regions show weak scene-dependent features.

  1. Automated Author Aiding System Conference

    DTIC Science & Technology

    1985-07-01

    0V) 0 Technical Report 684 r-Vass A Automated Author Aiding System Conference: Final Report edited by Nancy K. Atwood University of California at...AUTHOR AIDING SYSTEM CONFERENCE: Final Report FINAL REPORT June 84 through June 85 4. PERFORMING ORG. REPORT NUMBER 7. AUTHOM(I4~dited by Nancy K...Dots Entered) Technical Report 684 Automated Author Aiding System Conference: Final Report edited by Nancy K. Atwood University of California at Los

  2. Robotics/Automated Systems Technicians.

    ERIC Educational Resources Information Center

    Doty, Charles R.

    Major resources exist that can be used to develop or upgrade programs in community colleges and technical institutes that educate robotics/automated systems technicians. The first category of resources is Economic, Social, and Education Issues. The Office of Technology Assessment (OTA) report, "Automation and the Workplace," presents analyses of…

  3. Robotics/Automated Systems Technicians.

    ERIC Educational Resources Information Center

    Doty, Charles R.

    Major resources exist that can be used to develop or upgrade programs in community colleges and technical institutes that educate robotics/automated systems technicians. The first category of resources is Economic, Social, and Education Issues. The Office of Technology Assessment (OTA) report, "Automation and the Workplace," presents analyses of…

  4. Intraband radiometric performance of the Landsat Thematic Mappers.

    USGS Publications Warehouse

    Kieffer, H.H.; Cook, D.A.; Eliason, E.M.; Eliason, P.T.

    1985-01-01

    Radiometric characteristics have been examined of the Landsat-4 and Landsat-5 Thematic Mappers (TMs) that can be established without absolute calibration of spectral data. This analysis is based on radiometrically and geometrically raw (B-type) data of both uniform (flat-field) and high-contrast scenes. Subscenes selected for uniform radiance were used to characterized subtle radiometric differences and noise problems. Although the general performance of the Thematic Mappers is excellent, various anomalies that have a magnitude of a few digital levels (DN) or less are quantified. -from Authors

  5. Radiometric cloud imaging with an uncooled microbolometer thermal infrared camera.

    PubMed

    Shaw, Joseph; Nugent, Paul; Pust, Nathan; Thurairajah, Brentha; Mizutani, Kohei

    2005-07-25

    An uncooled microbolometer-array thermal infrared camera has been incorporated into a remote sensing system for radiometric sky imaging. The radiometric calibration is validated and improved through direct comparison with spectrally integrated data from the Atmospheric Emitted Radiance Interferometer (AERI). With the improved calibration, the Infrared Cloud Imager (ICI) system routinely obtains sky images with radiometric uncertainty less than 0.5 W/(m(2 )sr) for extended deployments in challenging field environments. We demonstrate the infrared cloud imaging technique with still and time-lapse imagery of clear and cloudy skies, including stratus, cirrus, and wave clouds.

  6. Laboratory Measurement of Bidirectional Reflectance of Radiometric Tarps

    NASA Technical Reports Server (NTRS)

    Knowlton, Kelly

    2006-01-01

    Objectives: a) To determine the magnitude of radiometric tarp BRDF; b) To determine whether an ASD FieldSpec Pro spectroradiometer can be used to perform the experiment. Radiometric tarps with nominal reflectance values of 52%, 35%, and 3.5%, deployed for IKONOS. QuickBird, and OrbView-3 overpasses Ground-based spectroradiometric measurements of tarp and Spectralon@ panel taken during overpass using ASD FieldSpec Pro spectroradiometer, and tarp reflectance calculated. Reflectance data used in atmospheric radiative transfer model (MODTRAN) to predict satellite at-sensor radiance for radiometric calibration. Reflectance data also used to validate atmospheric correction of high-spatial-resolution multispectral image products

  7. Improved Absolute Radiometric Calibration of a UHF Airborne Radar

    NASA Technical Reports Server (NTRS)

    Chapin, Elaine; Hawkins, Brian P.; Harcke, Leif; Hensley, Scott; Lou, Yunling; Michel, Thierry R.; Moreira, Laila; Muellerschoen, Ronald J.; Shimada, Joanne G.; Tham, Kean W.; hide

    2015-01-01

    The AirMOSS airborne SAR operates at UHF and produces fully polarimetric imagery. The AirMOSS radar data are used to produce Root Zone Soil Moisture (RZSM) depth profiles. The absolute radiometric accuracy of the imagery, ideally of better than 0.5 dB, is key to retrieving RZSM, especially in wet soils where the backscatter as a function of soil moisture function tends to flatten out. In this paper we assess the absolute radiometric uncertainty in previously delivered data, describe a method to utilize Built In Test (BIT) data to improve the radiometric calibration, and evaluate the improvement from applying the method.

  8. MODIS On-orbit Radiometric Calibration Algorithms

    NASA Astrophysics Data System (ADS)

    Xiong, X.; Chiang, K.; Adimi, F.; Sun, J.; Esposito, J.; Barnes, W. L.

    2002-05-01

    The MODerate Resolution Imaging Spectroradiometer (MODIS), a key instrument for NASA's Earth Observing System (EOS), consists of 36 spectral bands with wavelengths ranging form 0.41 micron to 14.4 microns and spatial resolutions of 0.25km (2 bands), 0.5km (5 bands), and 1.0km at nadir. The 36 spectral bands are distributed on four Focal Plane Assemblies (FPA): visible (VIS), near-infrared (NIR), short- and mid-wave infrared (SMIR), and long-wave infrared (LWIR). A Spectral Radiometric Calibration Assembly (SRCA), built into the MODIS instrument, is used to characterize the relative band to band registration and VIS and NIR bands' spectral stability. The MODIS 2-sided paddle wheel scan mirror provides a -55 degree to +55 degree scan of the Earth covering a 10km (at nadir) along track by 2330km along scan swath. The MODIS ProtoFlight Model (PFM) was launched on-board the EOS Terra spacecraft on December 18, 1999 (Sun-synchronous near polar orbit, 10:30 am equator crossing time, descending node). MODIS has been providing the science community global coverage of the land, oceans, and atmosphere. A second instrument, the Flight Model 1 (FM1), will be launched on the EOS Aqua spacecraft in April 2002 (Sun-synchronous near polar orbit, 1:30 pm equator crossing time, ascending node). The MODIS Characterization Support Team (MCST), funded by the MODIS Science Team, is responsible for the instrument pre-launch and on-orbit calibration and characterization and for developing, maintaining, and improving the Level 1B algorithm that converts the instrument digital counts to radiometrically calibrated top of the atmosphere (TOA) radiance and reflectance products. The Level1B data, along with other science products (oceans, land, and atmosphere), are freely available to the public through NASA Goddard Earth Science (GES) Distributed Active Archive Center (DAAC). The MODIS 20 reflective solar bands (RSB) from 0.41 to 2.1 microns are calibrated on-orbit by a solar diffuser (SD) and

  9. Automated Management Of Documents

    NASA Technical Reports Server (NTRS)

    Boy, Guy

    1995-01-01

    Report presents main technical issues involved in computer-integrated documentation. Problems associated with automation of management and maintenance of documents analyzed from perspectives of artificial intelligence and human factors. Technologies that may prove useful in computer-integrated documentation reviewed: these include conventional approaches to indexing and retrieval of information, use of hypertext, and knowledge-based artificial-intelligence systems.

  10. Automated Management Of Documents

    NASA Technical Reports Server (NTRS)

    Boy, Guy

    1995-01-01

    Report presents main technical issues involved in computer-integrated documentation. Problems associated with automation of management and maintenance of documents analyzed from perspectives of artificial intelligence and human factors. Technologies that may prove useful in computer-integrated documentation reviewed: these include conventional approaches to indexing and retrieval of information, use of hypertext, and knowledge-based artificial-intelligence systems.

  11. Radiometric detection of yeasts in blood cultures of cancer patients

    SciTech Connect

    Hopfer, R.L.; Orengo, A.; Chesnut, S.; Wenglar, M.

    1980-09-01

    During a 12-month period, 19,457 blood cultures were collected. Yeasts were isolated from 193 cultures derived from 76 cancer patients. Candida albicans or Candida tropicalis accounted for 79% of isolates. Of the three methods compared, the radiometric method required 2.9 days to become positive, blind subculture required 2.6 days, and Gram stains required 1 day. However, the radiometric method was clearly superior in detecting positive cultures, since 73% of all cultures were first detected radiometrically, 22% were detected by subculture, and only 5% were detected by Gram stain. Although 93% of the isolates were detected by aerobic culture, five (7%) isolates were obtained only from anaerobic cultures. Seven days of incubation appear to be sufficient for the radiometric detection of yeasts.

  12. [VMTBB-Based Spectral Radiometric Calibration of NIR Fiber Coupled Spectrometer].

    PubMed

    Zheng, Feng; Liu, Li-ying; Liu, Xiao-xi; Li, Ye; Shi, Xiao-guang; Zhang, Guo-yu; Huan, Ke-wei

    2015-09-01

    The medium temperature black body (MTBB) is conventional high precision equipment used as spectral radiometric scale in infrared spectral region. However, in near-infrared (NIR) spectral region, there are few papers about spectral radiometric calibration by using MTBB, that is because NIR spectral region is the borderland of its effective spectral region. The main research of this paper is spectral radiometric calibration method by using MTBB in NIR spectral region. Accordingly, this paper is devoted mostly to a discussion of how the calibration precision could be affected by selecting different structural parameters of calibration model. The purpose of this paper is to present the results of research and provide technical reference for improving the traceability in NIR spectral radiometric calibration. In this paper, a NIR fiber coupled spectrometer, whose wavelength range covers from 950 to 1700 nm, has been calibrated by a MTBB with adjustable temperature range from 50 to 1050 °C. Concentrating on calibration process, two key points have been discussed. For one thing, the geometric factors of radiation transfer model of the calibration systems have been compared between traditional structure and fiber direct-coupled structure. Because the fiber direct-coupled model is simple and effective, it has been selected instead of traditional model based on the radiation transfer between two coaxial discs. So, it is an advantaged radiation transfer model for radiometric calibration of fiber coupled spectrometer. For another thing, the relation between calibration accuracy and structural parameters of calibration model has been analyzed intensively. The root cause is scale feature of attribute of calibration data itself, which is the nonlinear structure in scales of spectral data. So, the high precision calibration needs nonlinear calibration model, and the uniform sampling for scale feature is also very important. Selecting sample is an inevitable problem when the

  13. Radiometric detection of the metabolic activity of Mycobacterium tuberculosis.

    PubMed

    Cummings, D M; Ristroph, D; Camargo, E E; Larson, S M; Wagner, H N

    1975-12-01

    A radiometric test capable of detecting the metabolic rate of M. tuberculosis within 18 hr after inoculation has been developed. The technique is based on the measurement of 14CO2 produced by the bacterial metabolism of 14C-U-glycerol of 14C-U-acetate. The test is an important first step in the development of rapid radiometric techniques for clinical study of Mycobacterium tuberculosis.

  14. Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurements

    DTIC Science & Technology

    2013-09-30

    Radiometric Measurements Dick K.P. Yue Center for Ocean Engineering Massachusetts Institute of Technology Room 5-321 77 Massachusetts Ave...comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE 30 SEP 2013 2. REPORT TYPE 3. DATES ...COVERED 00-00-2013 to 00-00-2013 4. TITLE AND SUBTITLE Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurements 5a

  15. Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurement

    DTIC Science & Technology

    2013-09-30

    Radiometric Measurement Lian Shen Department of Mechanical Engineering & St. Anthony Falls Laboratory University of Minnesota Minneapolis, MN...information if it does not display a currently valid OMB control number. 1. REPORT DATE 30 SEP 2013 2. REPORT TYPE 3. DATES COVERED 00-00-2013 to 00-00...2013 4. TITLE AND SUBTITLE Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurement 5a. CONTRACT NUMBER 5b. GRANT NUMBER

  16. Radiometric Measurements of Powerline Cables at 94 GHz

    DTIC Science & Technology

    2001-02-01

    ARMY RESEARCH LABORATORY Radiometric Measurements of Powerline Cables at 94 GHz David A. Wikner and Thomas J. Pizzillo ARL-TR-837 February 2001...MD 20783-1197 ARL-TR-837 February 2001 Radiometric Measurements of Powerline Cables at 94 GHz David A. Wikner and Thomas J. Pizzillo Sensors and...collision avoidance system," Proc. SPIE 3088 (April 1997), pp 57-63. 5. D. Wikner and T. Pizzillo, "Measurement of nadir and near-nadir 94-GHz

  17. The Radiometric Bode's Law and Extrasolar Planets

    NASA Astrophysics Data System (ADS)

    Lazio, T. Joseph, W.; Farrell, W. M.; Dietrick, Jill; Greenlees, Elizabeth; Hogan, Emily; Jones, Christopher; Hennig, L. A.

    2004-09-01

    We predict the radio flux densities of the extrasolar planets in the current census, making use of an empirical relation-the radiometric Bode's law-determined from the five ``magnetic'' planets in the solar system (the Earth and the four gas giants). Radio emission from these planets results from solar wind-powered electron currents depositing energy in the magnetic polar regions. We find that most of the known extrasolar planets should emit in the frequency range 10-1000 MHz and, under favorable circumstances, have typical flux densities as large as 1 mJy. We also describe an initial, systematic effort to search for radio emission in low radio frequency images acquired with the Very Large Array (VLA). The limits set by the VLA images (~300 mJy) are consistent with, but do not provide strong constraints on, the predictions of the model. Future radio telescopes, such as the Low Frequency Array and the Square Kilometer Array, should be able to detect the known extrasolar planets or place austere limits on their radio emission. Planets with masses much lower than those in the current census will probably radiate below 10 MHz and will require a space-based array.

  18. Radiometric dating of the Siloam Tunnel, Jerusalem.

    PubMed

    Frumkin, Amos; Shimron, Aryeh; Rosenbaum, Jeff

    2003-09-11

    The historical credibility of texts from the Bible is often debated when compared with Iron Age archaeological finds (refs. 1, 2 and references therein). Modern scientific methods may, in principle, be used to independently date structures that seem to be mentioned in the biblical text, to evaluate its historical authenticity. In reality, however, this approach is extremely difficult because of poor archaeological preservation, uncertainty in identification, scarcity of datable materials, and restricted scientific access into well-identified worship sites. Because of these problems, no well-identified Biblical structure has been radiometrically dated until now. Here we report radiocarbon and U-Th dating of the Siloam Tunnel, proving its Iron Age II date; we conclude that the Biblical text presents an accurate historic record of the Siloam Tunnel's construction. Being one of the longest ancient water tunnels lacking intermediate shafts, dating the Siloam Tunnel is a key to determining where and when this technological breakthrough took place. Siloam Tunnel dating also refutes a claim that the tunnel was constructed in the second century bc.

  19. Calibrated infrared ground/air radiometric spectrometer

    NASA Astrophysics Data System (ADS)

    Silk, J. K.; Schildkraut, Elliot Robert; Bauldree, Russell S.; Goodrich, Shawn M.

    1996-06-01

    The calibrated infrared ground/air radiometric spectrometer (CIGARS) is a new high performance, multi-purpose, multi- platform Fourier transform spectrometer (FPS) sensor. It covers the waveband from 0.2 to 12 micrometer, has spectral resolution as fine as 0.3 cm-1, and records over 100 spectra per second. Two CIGARS units are being used for observations of target signatures in the air or on the ground from fixed or moving platforms, including high performance jet aircraft. In this paper we describe the characteristics and capabilities of the CIGARS sensor, which uses four interchangeable detector modules (Si, InGaAs, InSb, and HgCdTe) and two optics modules, with internal calibration. The data recording electronics support observations of transient events, even without precise information on the timing of the event. We present test and calibration data on the sensitivity, spectral resolution, stability, and spectral rate of CIGARS, and examples of in- flight observations of real targets. We also discuss plans for adapting CIGARS for imaging spectroscopy observations, with simultaneous spectral and spatial data, by replacing the existing detectors with a focal plane array (FPA).

  20. Blast investigation by fast multispectral radiometric analysis

    NASA Astrophysics Data System (ADS)

    Devir, A. D.; Bushlin, Y.; Mendelewicz, I.; Lessin, A. B.; Engel, M.

    2011-06-01

    Knowledge regarding the processes involved in blasts and detonations is required in various applications, e.g. missile interception, blasts of high-explosive materials, final ballistics and IED identification. Blasts release large amount of energy in short time duration. Some part of this energy is released as intense radiation in the optical spectral bands. This paper proposes to measure the blast radiation by a fast multispectral radiometer. The measurement is made, simultaneously, in appropriately chosen spectral bands. These spectral bands provide extensive information on the physical and chemical processes that govern the blast through the time-dependence of the molecular and aerosol contributions to the detonation products. Multi-spectral blast measurements are performed in the visible, SWIR and MWIR spectral bands. Analysis of the cross-correlation between the measured multi-spectral signals gives the time dependence of the temperature, aerosol and gas composition of the blast. Farther analysis of the development of these quantities in time may indicate on the order of the detonation and amount and type of explosive materials. Examples of analysis of measured explosions are presented to demonstrate the power of the suggested fast multispectral radiometric analysis approach.

  1. Transportable high sensitivity small sample radiometric calorimeter

    SciTech Connect

    Wetzel, J.R.; Biddle, R.S.; Cordova, B.S.; Sampson, T.E.; Dye, H.R.; McDow, J.G.

    1998-12-31

    A new small-sample, high-sensitivity transportable radiometric calorimeter, which can be operated in different modes, contains an electrical calibration method, and can be used to develop secondary standards, will be described in this presentation. The data taken from preliminary tests will be presented to indicate the precision and accuracy of the instrument. The calorimeter and temperature-controlled bath, at present, require only a 30-in. by 20-in. tabletop area. The calorimeter is operated from a laptop computer system using unique measurement module capable of monitoring all necessary calorimeter signals. The calorimeter can be operated in the normal calorimeter equilibration mode, as a comparison instrument, using twin chambers and an external electrical calibration method. The sample chamber is 0.75 in (1.9 cm) in diameter by 2.5 in. (6.35 cm) long. This size will accommodate most {sup 238}Pu heat standards manufactured in the past. The power range runs from 0.001 W to <20 W. The high end is only limited by sample size.

  2. Technical Note: A fully automated purge and trap GC-MS system for quantification of volatile organic compound (VOC) fluxes between the ocean and atmosphere

    NASA Astrophysics Data System (ADS)

    Andrews, S. J.; Hackenberg, S. C.; Carpenter, L. J.

    2015-04-01

    The oceans are a key source of a number of atmospherically important volatile gases. The accurate and robust determination of trace gases in seawater is a significant analytical challenge, requiring reproducible and ideally automated sample handling, a high efficiency of seawater-air transfer, removal of water vapour from the sample stream, and high sensitivity and selectivity of the analysis. Here we describe a system that was developed for the fully automated analysis of dissolved very short-lived halogenated species (VSLS) sampled from an under-way seawater supply. The system can also be used for semi-automated batch sampling from Niskin bottles filled during CTD (conductivity, temperature, depth) profiles. The essential components comprise a bespoke, automated purge and trap (AutoP & T) unit coupled to a commercial thermal desorption and gas chromatograph mass spectrometer (TD-GC-MS). The AutoP & T system has completed five research cruises, from the tropics to the poles, and collected over 2500 oceanic samples to date. It is able to quantify >25 species over a boiling point range of 34-180 °C with Henry's law coefficients of 0.018 and greater (CH22l, kHcc dimensionless gas/aqueous) and has been used to measure organic sulfurs, hydrocarbons, halocarbons and terpenes. In the eastern tropical Pacific, the high sensitivity and sampling frequency provided new information regarding the distribution of VSLS, including novel measurements of a photolytically driven diurnal cycle of CH22l within the surface ocean water.

  3. Development of automated welding process for field fabrication of thick walled pressure vessels. Fourth quarter technical progress report for period ending September 28, 1980

    SciTech Connect

    Not Available

    1980-01-01

    Progress is reported in research aimed at optimizing an automated welding process for the field fabrication of thick-walled pressure vessels and for evaluating the welded joints. Information is included on the welding equipment, mechanical control of the process, joint design, filler wire optimization, in-process nondestructive testing of welds, and repair techniques. (LCL)

  4. Technical note: Comparative analyses of the quality and yield of genomic DNA from invasive and noninvasive, automated and manual extraction methods.

    PubMed

    Foley, C; O'Farrelly, C; Meade, K G

    2011-06-01

    Several new automated methods have recently become available for high-throughput DNA extraction, including the Maxwell 16 System (Promega UK, Southampton, UK). The purpose of this report is to compare automated with manual DNA extraction methods, and invasive with noninvasive sample collection methods, in terms of DNA yield and quality. Milk, blood, and nasal swab samples were taken from 10 cows for DNA extraction. Nasal swabs were also taken from 10 calves and semen samples from 15 bulls for comparative purposes. The Performagene Livestock (DNA Genotek, Kanata, Ontario, Canada) method was compared with similar samples taken from the same animal using manual extraction methods. All samples were analyzed using both the Qubit Quantification Platform (Invitrogen Ltd., Paisley, UK) and NanoDrop spectrophotometer (NanoDrop Technologies, Inc., Wilmington, DE) to accurately assess DNA quality and quantity. In general, the automated Maxwell 16 System performed best, consistently yielding high quantity and quality DNA across the sample range tested. Average yields of 28.7, 10.3, and 19.2 μg of DNA were obtained from 450 μL of blood, 400 μL of milk, and a single straw of semen, respectively. The quality of DNA obtained from buffy coat and from semen was significantly higher with the automated method than with the manual methods (260/280 ratio of 1.9 and 1.8, respectively). Centrifugation of whole blood facilitated the concentration of leukocytes in the buffy coat, which significantly increased DNA yield after manual extraction. The Performagene method also yielded 18.4 and 49.8 μg of high quality (260/280 ratio of 1.8) DNA from the cow and calf nasal samples, respectively. These results show the advantages of noninvasive sample collection and automated methods for high-throughput extraction and biobanking of high quality DNA. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Recovery, compilation, back-calibration, and standardization of existing radiometric survey data: Namibia, southern Africa

    SciTech Connect

    Duffy, A.; Urquhart, W.E.S.; Eberle, D.G.; Grasty, R.L.; Hutchins, D.G.

    1994-12-31

    During 1992 and 1993 select portions of existing government airborne radiometric data covering almost 91,000 km{sup 2} of central Namibia were compiled into a master digital data set. This compilation involved the interactive, semi-automated digital recovery of approximately 42,000 line kilometers of original analogue chart traces. A further 49,000 line kilometers of digital data were also reprocessed. Available data represented ten (10) different surveys collected over twelve (12) years with a variety of spectrometers, spectral windows and survey parameters. Preliminary digital grids of each radioelement were compiled, verified and used to select representative sites for ground measurements within each survey block. Results obtained from the ground program were used to back-calibrate the airborne data, standardize the various surveys and convert airborne measurements into equivalent ground concentrations of uranium, thorium and potassium. The quality and consistency of final map products conclusively demonstrates that existing analogue radiometric data, in various states of preservation, can be successfully recovered, combined with ``modern`` digital data, and utilized to assist exploration, mapping and environmental studies.

  6. A Radiometric All-Sky Infrared Camera (RASICAM) for DES/CTIO

    SciTech Connect

    Lewis, Peter M.; Rogers, Howard; Schindler, Rafe H.; /SLAC

    2010-08-25

    A novel radiometric all-sky infrared camera [RASICAM] has been constructed to allow automated real-time quantitative assessment of night sky conditions for the Dark Energy Camera [DECam] located on the Blanco Telescope at the Cerro Tololo Inter-American Observatory in Chile. The camera is optimized to detect the position, motion and optical depth of thin, high (8-10km) cirrus clouds and contrails by measuring their apparent temperature above the night sky background. The camera system utilizes a novel wide-field equiresolution catadioptic mirror system that provides sky coverage of 2{pi} azimuth and 14-90{sup o} from zenith. Several new technological and design innovations allow the RASICAM system to provide unprecedented cloud detection and IR-based photometricity quantification. The design of the RASICAM system is presented.

  7. Large scale W-band focal plane array for passive radiometric imaging

    NASA Astrophysics Data System (ADS)

    Dow, G. S.; Lo, D. C. W.; Guo, Y.; Lin, E. W.; Chung, T. T.; Biedenbender, M. D.; Miromontes, O.; Mirashi, A.; Yujiri, L.; Lee, P. S. C.; Shoucri, M. M.; Allen, B. R.

    1996-06-01

    This paper discusses the development of a large scale W-band focal plane array (FPA) for passive radiometric imaging application. The goal is to develop a 40x26 (1040-pixels) FPA to cover 15deg x 10deg instantaneous field-of-view. Each receiver consists of a single direct detection MMIC which is a W-band high gain, wide bandwidth switched LNA with integrated Schottky barrier diode detector. A 1x4 FPA module, employing linearly tapered slot antenna, is used as the basic building block for the FPA. Typical receiver temperature sensitivity is 0.4 K with 10 ms integration time. For the first time, an automated assembly process is used to produce W-band MMIC modules in large volume.

  8. Experimental tests and radiometric calculations for the feasibility of fluorescence LIDAR-based discrimination of oil spills from UAV

    NASA Astrophysics Data System (ADS)

    Raimondi, Valentina; Palombi, Lorenzo; Lognoli, David; Masini, Andrea; Simeone, Emilio

    2017-09-01

    This paper presents experimental tests and radiometric calculations for the feasibility of an ultra-compact fluorescence LIDAR from an Unmanned Air Vehicle (UAV) for the characterisation of oil spills in natural waters. The first step of this study was to define the experimental conditions for a LIDAR and its budget constraints on the basis of the specifications of small UAVs already available on the market. The second step consisted of a set of fluorescence LIDAR measurements on oil spills in the laboratory in order to propose a simplified discrimination method and to calculate the oil fluorescence conversion efficiency. Lastly, the main technical specifications of the payload were defined and radiometric calculations carried out to evaluate the performances of both the payload and the proposed discrimination method.

  9. Technical Note: A fully automated purge and trap-GC-MS system for quantification of volatile organic compound (VOC) fluxes between the ocean and atmosphere

    NASA Astrophysics Data System (ADS)

    Andrews, S. J.; Hackenberg, S. C.; Carpenter, L. J.

    2014-12-01

    The oceans are a key source of a number of atmospherically important volatile gases. The accurate and robust determination of trace gases in seawater is a significant analytical challenge, requiring reproducible and ideally automated sample handling, a high efficiency of seawater-air transfer, removal of water vapour from the sample stream, and high sensitivity and selectivity of the analysis. Here we describe a system that was developed for the fully automated analysis of dissolved very short-lived halogenated species (VSLS) sampled from an under-way seawater supply. The system can also be used for semi-automated batch sampling from Niskin bottles filled during CTD (Conductivity, Temperature, Depth) profiles. The essential components comprise of a bespoke, automated purge and trap (AutoP & T) unit coupled to a commercial thermal desorption and gas chromatograph-mass spectrometer (TD-GC-MS). The AutoP & T system has completed five research cruises, from the tropics to the poles, and collected over 2500 oceanic samples to date. It is able to quantify >25 species over a boiling point range of 34-180 °C with Henry's Law coefficients of 0.018 and greater (CH2I2, kHcc dimensionless gas/aqueous) and has been used to measure organic sulfurs, hydrocarbons, halocarbons and terpenes. In the east tropical Pacific, the high sensitivity and sampling frequency provided new information regarding the distribution of VSLS, including novel measurements of a photolytically driven diurnal cycle of CH2I2 within the surface ocean water.

  10. Radiometric validation of NASA's Ames Research Center's Sensor Calibration Laboratory.

    PubMed

    Brown, Steven W; Johnson, B Carol; Biggar, Stuart F; Zalewski, Edward F; Cooper, John; Hajek, Pavel; Hildum, Edward; Grant, Patrick; Barnes, Robert A; Butler, James J

    2005-10-20

    The National Aeronautics and Space Administration's (NASA's) Ames Research Center's Airborne Sensor Facility (ASF) is responsible for the calibration of several airborne Earth-viewing sensor systems in support of NASA Earth Observing System (EOS) investigations. The primary artifact used to calibrate these sensors in the reflective solar region from 400 to 2500 nm is a lamp-illuminated integrating sphere source. In September 1999, a measurement comparison was made at the Ames ASF Sensor Calibration Facility to validate the radiometric scale, establish the uncertainties assigned to the radiance of this source, and examine its day-to-day repeatability. The comparison was one of a series of validation activities overseen by the EOS Calibration Program to ensure the radiometric calibration accuracy of sensors used in long-term, global, remote-sensing studies. Results of the comparison, including an evaluation of the Ames Sensor Calibration Laboratory (SCL) measurement procedures and assigned radiometric uncertainties, provide a validation of their radiometric scale at the time of the comparison. Additionally, the maintenance of the radiance scale was evaluated by use of independent, long-term, multiyear radiance validation measurements of the Ames sphere source. This series of measurements provided an independent assessment of the radiance values assigned to integrating sphere sources by the Ames SCF. Together, the measurements validate the SCF radiometric scale and assigned uncertainties over the time period from September 1999 through July 2003.

  11. Radiometric validation of NASA's Ames Research Center's Sensor Calibration Laboratory

    SciTech Connect

    Brown, Steven W.; Johnson, B. Carol; Biggar, Stuart F.; Zalewski, Edward F.; Cooper, John; Hajek, Pavel; Hildum, Edward; Grant, Patrick; Barnes, Robert A.; Butler, James J

    2005-10-20

    The National Aeronautics and Space Administration's (NASA's) Ames Research Center's Airborne Sensor Facility (ASF) is responsible for the calibration of several airborne Earth-viewing sensor systems in support of NASA Earth Observing System (EOS) investigations. The primary artifact used to calibrate these sensors in the reflective solar region from 400 to 2500 nm is a lamp-illuminated integrating sphere source. In September 1999, a measurement comparison was made at the Ames ASF Sensor Calibration Facility to validate the radiometric scale, establish the uncertainties assigned to the radiance of this source, and examine its day-to-day repeatability. The comparison was one of a series of validation activities overseen by the EOS Calibration Program to ensure the radiometric calibration accuracy of sensors used in long-term, global, remote-sensing studies. Results of the comparison, including an evaluation of the Ames Sensor Calibration Laboratory (SCL) measurement procedures and assigned radiometric uncertainties, provide a validation of their radiometric scale at the time of the comparison. Additionally, the maintenance of the radiance scale was evaluated by use of independent, long-term, multiyear radiance validation measurements of the Ames sphere source. This series of measurements provided an independent assessment of the radiance values assigned to integrating sphere sources by the Ames SCF. Together, the measurements validate the SCF radiometric scale and assigned uncertainties over the time period from September 1999 through July 2003.

  12. Deep Space Network Radiometric Remote Sensing Program

    NASA Technical Reports Server (NTRS)

    Walter, Steven J.

    1994-01-01

    Planetary spacecraft are viewed through a troposphere that absorbs and delays radio signals propagating through it. Tropospheric water, in the form of vapor, cloud liquid, and precipitation, emits radio noise which limits satellite telemetry communication link performance. Even at X-band, rain storms have severely affected several satellite experiments including a planetary encounter. The problem will worsen with DSN implementation of Ka-band because communication link budgets will be dominated by tropospheric conditions. Troposphere-induced propagation delays currently limit VLBI accuracy and are significant sources of error for Doppler tracking. Additionally, the success of radio science programs such as satellite gravity wave experiments and atmospheric occultation experiments depends on minimizing the effect of water vapor-induced propagation delays. In order to overcome limitations imposed by the troposphere, the Deep Space Network has supported a program of radiometric remote sensing. Currently, water vapor radiometers (WVRs) and microwave temperature profilers (MTPs) support many aspects of the Deep Space Network operations and research and development programs. Their capability to sense atmospheric water, microwave sky brightness, and atmospheric temperature is critical to development of Ka-band telemetry systems, communication link models, VLBI, satellite gravity wave experiments, and radio science missions. During 1993, WVRs provided data for propagation model development, supported planetary missions, and demonstrated advanced tracking capability. Collection of atmospheric statistics is necessary to model and predict performance of Ka-band telemetry links, antenna arrays, and radio science experiments. Since the spectrum of weather variations has power at very long time scales, atmospheric measurements have been requested for periods ranging from one year to a decade at each DSN site. The resulting database would provide reliable statistics on daily

  13. Deep Space Network Radiometric Remote Sensing Program

    NASA Technical Reports Server (NTRS)

    Walter, Steven J.

    1994-01-01

    Planetary spacecraft are viewed through a troposphere that absorbs and delays radio signals propagating through it. Tropospheric water, in the form of vapor, cloud liquid, and precipitation, emits radio noise which limits satellite telemetry communication link performance. Even at X-band, rain storms have severely affected several satellite experiments including a planetary encounter. The problem will worsen with DSN implementation of Ka-band because communication link budgets will be dominated by tropospheric conditions. Troposphere-induced propagation delays currently limit VLBI accuracy and are significant sources of error for Doppler tracking. Additionally, the success of radio science programs such as satellite gravity wave experiments and atmospheric occultation experiments depends on minimizing the effect of water vapor-induced propagation delays. In order to overcome limitations imposed by the troposphere, the Deep Space Network has supported a program of radiometric remote sensing. Currently, water vapor radiometers (WVRs) and microwave temperature profilers (MTPs) support many aspects of the Deep Space Network operations and research and development programs. Their capability to sense atmospheric water, microwave sky brightness, and atmospheric temperature is critical to development of Ka-band telemetry systems, communication link models, VLBI, satellite gravity wave experiments, and radio science missions. During 1993, WVRs provided data for propagation model development, supported planetary missions, and demonstrated advanced tracking capability. Collection of atmospheric statistics is necessary to model and predict performance of Ka-band telemetry links, antenna arrays, and radio science experiments. Since the spectrum of weather variations has power at very long time scales, atmospheric measurements have been requested for periods ranging from one year to a decade at each DSN site. The resulting database would provide reliable statistics on daily

  14. Validation of EO-1 Hyperion and Advanced Land Imager Using the Radiometric Calibration Test Site at Railroad Valley, Nevada

    NASA Technical Reports Server (NTRS)

    Czapla-Myers, Jeffrey; Ong, Lawrence; Thome, Kurtis; McCorkel, Joel

    2015-01-01

    The Earth-Observing One (EO-1) satellite was launched in 2000. Radiometric calibration of Hyperion and the Advanced Land Imager (ALI) has been performed throughout the mission lifetime using various techniques that include ground-based vicarious calibration, pseudo-invariant calibration sites, and also the moon. The EO-1 mission is nearing its useful lifetime, and this work seeks to validate the radiometric calibration of Hyperion and ALI from 2013 until the satellite is decommissioned. Hyperion and ALI have been routinely collecting data at the automated Radiometric Calibration Test Site [RadCaTS/Railroad Valley (RRV)] since launch. In support of this study, the frequency of the acquisitions at RadCaTS has been significantly increased since 2013, which provides an opportunity to analyze the radiometric stability and accuracy during the final stages of the EO-1 mission. The analysis of Hyperion and ALI is performed using a suite of ground instrumentation that measures the atmosphere and surface throughout the day. The final product is an estimate of the top-of-atmosphere (TOA) spectral radiance, which is compared to Hyperion and ALI radiances. The results show that Hyperion agrees with the RadCaTS predictions to within 5% in the visible and near-infrared (VNIR) and to within 10% in the shortwave infrared (SWIR). The 2013-2014 ALI results show agreement to within 6% in the VNIR and 7.5% in the SWIR bands. A cross comparison between ALI and the Operational Land Imager (OLI) using RadCaTS as a transfer source shows agreement of 3%-6% during the period of 2013-2014.

  15. Landsat-5 TM reflective-band absolute radiometric calibration

    USGS Publications Warehouse

    Chander, G.; Helder, D.L.; Markham, B.L.; Dewald, J.D.; Kaita, E.; Thome, K.J.; Micijevic, E.; Ruggles, T.A.

    2004-01-01

    The Landsat-5 Thematic Mapper (TM) sensor provides the longest running continuous dataset of moderate spatial resolution remote sensing imagery, dating back to its launch in March 1984. Historically, the radiometric calibration procedure for this imagery used the instrument's response to the Internal Calibrator (IC) on a scene-by-scene basis to determine the gain and offset of each detector. Due to observed degradations in the IC, a new procedure was implemented for U.S.-processed data in May 2003. This new calibration procedure is based on a lifetime radiometric calibration model for the instrument's reflective bands (1-5 and 7) and is derived, in part, from the IC response without the related degradation effects and is tied to the cross calibration with the Landsat-7 Enhanced Thematic Mapper Plus. Reflective-band absolute radiometric accuracy of the instrument tends to be on the order of 7% to 10%, based on a variety of calibration methods.

  16. Measurements and analysis of solar direct irradiance-meter on Dunhuang radiometric calibration sites

    NASA Astrophysics Data System (ADS)

    Liu, En-chao; Li, Xin; Zhang, Yan-na; Zheng, Xiao-bing; Yan, Jing

    2016-10-01

    In order to realize the quantitative application of satellite remote sensing data and adapt to the demand of field calibration of hyper-spectral remote sensors, the solar direct spectral irradiance-meter was developed. According to the sampling principle of spectral irradiance, the irradiance-meter was designed with some technical improvements, the radiometric calibration based on system-level detector were adopted. Irradiance-meter took part in field calibration experiment on Dunhuang radiometric calibration sites and the correct data results were collected. The measurement results of spectral irradiance were consistent with simulated ground irradiance by MODTRAN model. The relative deviation of atmospheric optical depth(AOD) compared with solar radiometer CE318 was less than 4.84%. The whole day results of the irradiance observations and atmospheric transmission in the data applications were collected, the local atmosphere mode and the change of environment were reflected accurately, the input information of the atmospheric parameter were provided for the study of atmospheric properties and field calibration of remote sensors.

  17. Development of Automated Production Line Processes for Solar Brightfield Modules: Final Annual Technical Progress Report, 1 July 2004 -- 15 October 2005

    SciTech Connect

    Nowlan, M. J.; Murach, J. M.; Sutherland, S. F.; Miller, D. C.; Moore S. B.; Hogan, S. J.

    2006-08-01

    Spire Corporation is addressing the Photovoltaic Manufacturing R&D project goals of improving photovoltaic (PV) manufacturing processes and products while reducing costs and providing a technology foundation that supports significant manufacturing scale-up. To accomplish this, we are focusing our efforts on the design of a large-area utility-scale module and the development of the necessary manufacturing techniques and equipment to manufacture such a module in a high-volume production environment. A three-phase program is under way for developing and demonstrating new automated systems for fabricating very large PV modules ideal for use in multi-megawatt grid-connected applications. We designed a large-area (1.57 m x 3.68 m) 800-W module, and we are developing associated module production equipment that will minimize the total installed system cost for utility-scale PV arrays. Activities in Phase 2 focused on the development of automation for module materials lay-up, cell string busing, and module lamination; enhancements to the cell stringing and lamination processes; and performance testing of large-area modules.

  18. Fully automated quantification of regional cerebral blood flow with three-dimensional stereotaxic region of interest template: validation using magnetic resonance imaging--technical note.

    PubMed

    Takeuchi, Ryo; Yonekura, Yoshiharu; Takeda, Shigenori Katayama Naoya; Fujita, Katsuzo; Konishi, Junji

    2003-03-01

    The previously reported three-dimensional stereotaxic region of interest (ROI) template (3DSRT-t) for the analysis of anatomically standardized technetium-99m-L,L-ethyl cysteinate dimer (99mTc-ECD) single photon emission computed tomography (SPECT) images was modified for use in a fully automated regional cerebral blood flow (rCBF) quantification software, 3DSRT, incorporating an anatomical standardization engine transplanted from statistical parametric mapping 99 and ROIs for quantification based on 3DSRT-t. Three-dimensional T2-weighted magnetic resonance images of 10 patients with localized infarcted areas were compared with the ROI contour of 3DSRT, and the positions of the central sulcus in the primary sensorimotor area were also estimated. All positions of the 20 lesions were in strict accordance with the ROI delineation of 3DSRT. The central sulcus was identified on at least one side of 210 paired ROIs and in the middle of 192 (91.4%) of these 210 paired ROIs among the 273 paired ROIs of the primary sensorimotor area. The central sulcus was recognized in the middle of more than 71.4% of the ROIs in which the central sulcus was identifiable in the respective 28 slices of the primary sensorimotor area. Fully automated accurate ROI delineation on anatomically standardized images is possible with 3DSRT, which enables objective quantification of rCBF and vascular reserve in only a few minutes using 99mTc-ECD SPECT images obtained by the RVR method.

  19. JACIE Radiometric Assessment of QuickBird Multispectral Imagery

    NASA Technical Reports Server (NTRS)

    Pagnutti, Mary; Carver, David; Holekamp, Kara; Knowlton, Kelly; Ryan, Robert; Zanoni, Vicki; Thome, Kurtis; Aaron, David

    2004-01-01

    Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can place confidence in the imagery they use and can fully understand its properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, the NASA Stennis Space Center (SSC) Earth Science Applications (ESA) directorate,through the Joint Agency for Commercial Imagery Evaluation (JACIE) framework, established a commercial imaging satellite radiometric calibration team consisting of two groups: 1) NASA SSC ESA, supported by South Dakota State University, and 2) the University of Arizona Remote Sensing Group. The two groups determined the absolute radiometric calibration coefficients of the Digital Globe 4-band, 2.4-m QuickBird multispectral product covering the visible through near-infrared spectral region. For a 2-year period beginning in 2002, both groups employed some variant of a reflectance-based vicarious calibration approach, which required ground-based measurements coincident with QuickBird image acquisitions and radiative transfer calculations. The groups chose several study sites throughout the United States that covered nearly the entire dynamic range of the QuickBird sensor. QuickBird at-sensor radiance values were compared with those estimated by the two independent groups to determine the QuickBird sensor's radiometric accuracy. Approximately 20 at-sensor radiance estimates were vicariously determined each year. The estimates were combined to provide a high-precision radiometric gain calibration coefficient. The results of this evaluation provide the user community with an independent assessment of the QuickBird sensor's absolute calibration and stability over the 2-year period. While the techniques and method described reflect those developed at the NASA SSC, the results of both JACIE team groups are

  20. Evaluation of computational radiometric and spectral sensor calibration techniques

    NASA Astrophysics Data System (ADS)

    Manakov, Alkhazur

    2016-04-01

    Radiometric and spectral calibration are essential for enabling the use of digital sensors for measurement purposes. Traditional optical calibration techniques require expensive equipment such as specialized light sources, monochromators, tunable filters, calibrated photo-diodes, etc. The trade-offs between computational and physics-based characterization schemes are, however, not well understood. In this paper we perform an analysis of existing computational calibration schemes and elucidate their weak points. We highlight the limitations by comparing against ground truth measurements performed in an optical characterization laboratory (EMVA 1288 standard). Based on our analysis, we present accurate and affordable methods for the radiometric and spectral calibration of a camera.

  1. Radiometric normalization with multi-image pseudo-invariant features

    NASA Astrophysics Data System (ADS)

    Barazzetti, Luigi; Gianinetto, Marco; Scaioni, Marco

    2016-08-01

    Radiometric image normalization is one of the basic pre-processing methods used in satellite time series analysis. This paper presents a new multi-image approach able to estimate the parameters of relative radiometric normalization through a multiple and simultaneous regression with a dataset of a generic number of images. The method was developed to overcome the typical drawbacks of standard one-to-one techniques, where image pairs are independently processed. The proposed solution is based on multi-image pseudo-invariant features incorporated into a unique regression solved via Least Squares. Results for both simulated and real data are presented and discussed.

  2. Automated Information Management for Designers: Functional Requirements for Computer Based Associates That Support Access and Use of Technical Information in Design

    DTIC Science & Technology

    1993-03-01

    Support Access and Use of Technical Information in IDcsign 1 William J. Cody R William B. Rouse 0 ~~~SEARCH TECHNOLOGY i m’N 4898 S. OLD PEACHTREE ROAD... information . Termed Designer’s Associates , these supports derive from a thorough understanding of designer’s tasks and the services that intelligent...8217 access and use of such information . Termed Designer’s Associates , these supports derive from a thorough understanding of designers’ tasks and the

  3. Process development for automated solar cell and module production. Task 4: Automated array assembly

    NASA Technical Reports Server (NTRS)

    1980-01-01

    A process sequence which can be used in conjunction with automated equipment for the mass production of solar cell modules for terrestrial use was developed. The process sequence was then critically analyzed from a technical and economic standpoint to determine the technological readiness of certain process steps for implementation. The steps receiving analysis were: back contact metallization, automated cell array layup/interconnect, and module edge sealing. For automated layup/interconnect, both hard automation and programmable automation (using an industrial robot) were studied. The programmable automation system was then selected for actual hardware development.

  4. Landsat-7 Enhanced Thematic Mapper plus radiometric calibration

    USGS Publications Warehouse

    Markham, B.L.; Boncyk, Wayne C.; Helder, D.L.; Barker, J.L.

    1997-01-01

    Landsat-7 is currently being built and tested for launch in 1998. The Enhanced Thematic Mapper Plus (ETM+) sensor for Landsat-7, a derivative of the highly successful Thematic Mapper (TM) sensors on Landsats 4 and 5, and the Landsat-7 ground system are being built to provide enhanced radiometric calibration performance. In addition, regular vicarious calibration campaigns are being planned to provide additional information for calibration of the ETM+ instrument. The primary upgrades to the instrument include the addition of two solar calibrators: the full aperture solar calibrator, a deployable diffuser, and the partial aperture solar calibrator, a passive device that allows the ETM+ to image the sun. The ground processing incorporates for the first time an off-line facility, the Image Assessment System (IAS), to perform calibration, evaluation and analysis. Within the IAS, processing capabilities include radiometric artifact characterization and correction, radiometric calibration from the multiple calibrator sources, inclusion of results from vicarious calibration and statistical trending of calibration data to improve calibration estimation. The Landsat Product Generation System, the portion of the ground system responsible for producing calibrated products, will incorporate the radiometric artifact correction algorithms and will use the calibration information generated by the IAS. This calibration information will also be supplied to ground processing systems throughout the world.

  5. Silicon crystal surface temperature: Computational and radiometric studies

    SciTech Connect

    Khounsary, A.M.; Kuzay, T.M.; Forster, G.A.

    1988-12-01

    The surface temperature of the three-channel, gallium cooled Cornell silicon crystal was evaluated for the given system configuration and specifications. The THTB thermal-hydraulic program is used for the numerical solution of the problem, and the results are to be compared with the radiometric measurements obtained at Cornell.

  6. Laboratory-based bidirectional reflectance distribution functions of radiometric tarps

    SciTech Connect

    Georgiev, Georgi T.; Butler, James J

    2008-06-20

    Laboratory-based bidirectional reflectance distribution functions (BRDFs) of radiometric tarp samples used in the vicarious calibration of Earth remote sensing satellite instruments are presented in this paper. The results illustrate the BRDF dependence on the orientation of the tarps' weft and warp threads. The study was performed using the GSFC scatterometer at incident zenith angles of 0 deg., 10 deg., and 30 deg.; scatter zenith angles from 0 deg. to 60 deg.; and scatter azimuth angles of 0 deg., 45 deg., 90 deg., 135 deg., and 180 deg.. The wavelengths were 485 nm, 550 nm, 633 nm, and 800 nm. The tarp's weft and warp dependence on BRDF is well defined at all measurement geometries and wavelengths. The BRDF difference can be as high as 8% at 0 deg. incident angle and 12% at 30 deg. incident angle. The fitted BRDF data show a very small discrepancy from the measured ones. New data on the forward and backscatter properties of radiometric tarps are reported. The backward scatter is well pronounced for the white samples. The black sample has well-pronounced forward scatter. The provided BRDF characterization of radiometric tarps is an excellent reference for anyone interested in using tarps for radiometric calibrations. The results are NIST traceable.

  7. Radiometric estimation of water vapor content over Brazil

    NASA Astrophysics Data System (ADS)

    Karmakar, P. K.; Maiti, M.; Sett, S.; Angelis, C. F.; Machado, L. A. T.

    2011-11-01

    A multi-channel microwave radiometre (make: Radiometrics Corporation) is installed at Instituto Nacional de Pesquisas Espaciais-INPE, Brazil (22°S). The radiometric output of two channels of the radiometer in the form of brightness temperature at 23.834 GHz and 30 GHz, initially, were used to find out the ambient water vapor content and the non-precipitable cloud liquid water content. The necessary algorithm was developed for the purpose. The best results were obtained using the hinge frequency 23.834 GHz and 30 GHz pair having an r.m.s. error of only 2.64. The same methodology was then adopted exploiting 23.034 GHz and 30 GHz pair. In that case the r.m.s. error was 3.42. These results were then compared with those obtained over Kolkata (22°N), India, by using 22.234 GHz and 31.4 GHz radiometric data. This work conclusively suggests the use of a frequency should not be at the water vapor resonance line. Instead, while measuring the vapor content for separation of vapor and cloud liquid, one of them should be a few GHz left or right from the resonance line i.e., at 23.834 GHz and the other one should be around 30 GHz.

  8. A Non-Radiative Transfer Approach to Radiometric Vicarious Calibration

    NASA Technical Reports Server (NTRS)

    Ryan, Robert; Holekamp, Kara; Pagnutti, Mary; Stanley, Thomas

    2007-01-01

    TOA (top-of-atmosphere) radiance from high-spatial-resolution satellite imagery systems is important for a wide variety of research and applications. Many research initiatives require data with absolute radiometric accuracy better than a few percent. The conversion of satellite digital numbers to radiance depends on accurate radiometric calibration. A common method for determining and validating radiometric calibrations is to rely upon vicarious calibration approaches. Historically, vicarious calibration methods use radiative transfer codes with ground-based atmosphere and surface reflectance or radiance inputs for estimating TOA radiance values. These TOA radiance values are compared against the satellite digital numbers to determine the radiometric calibration. However, the radiative transfer codes used depend on many assumptions about the aerosol properties and the atmospheric point spread function. A measurement-based atmospheric radiance estimation approach for high-spatial-resolution, multispectral, visible/near-infrared sensors is presented that eliminates the use of radiative transfer codes and many of the underlying assumptions. A comparison between the radiative transfer and non-radiative transfer approaches is made.

  9. A preliminary study of a very large space radiometric antenna

    NASA Technical Reports Server (NTRS)

    Agrawal, P. K.

    1979-01-01

    An approach used to compute the size of a special radiometric reflector antenna is presented. Operating at 1 GHz, this reflector is required to produce 200 simultaneous contiguous beams, each with a 3 dB footprint of 1 km from an assumed satellite height of 650 km. The overall beam efficiency for each beam is required to be more than 90%.

  10. Radiometric sources for the Los Alamos National Laboratory calibration Laboratory

    SciTech Connect

    Maier, W.B. II; Holland, R.; Bender, S.; Byrd, D.; Michaud, F.D.; Moore, S.; O`Brian, T.R.

    1994-07-01

    Los Alamos is developing a laboratory that will support state of the art calibration of moderate-aperture instrumentation (< 40 cm diameter) having high spatial and thermal resolution. Highly accurate calibration in the reflected solar and thermal infrared spectral regions are required for newly developed instrumentation. Radiometric calibration of the instrumentation requires well-characterized, extensive sources of radiation from 0.45 to 12 {mu}m. For wavelengths above 2.5 {mu}m, blackbodies having temperature control and radiometric uniformity to within 100 mK are being designed and will be radiometrically characterized at the National Institute of Standards and Technology (NIST). For the spectral range 0.45--2.5 {mu}m, a ``whitebody`` integrating sphere equipped with tungsten-halogen lamps and enclosed inside a vacuum shroud will be used; this vacuum-compatible extensive standard diffuse source utilizes well-known technology and will be characterized at NIST`s existing facilities. Characterization of instrumental contrast performance for wavelengths, {lambda}, beyond 2.5 {mu}m will utilize a recently designed absolute variable-contrast IR radiometric calibrator, and preliminary data indicate that this calibrator will perform satisfactorily. Conceptual design and status of these extensive broad-band sources and of a monochromatic source to be used for spectral calibrations will be presented.

  11. A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration

    PubMed Central

    Kashani, Alireza G.; Olsen, Michael J.; Parrish, Christopher E.; Wilson, Nicholas

    2015-01-01

    In addition to precise 3D coordinates, most light detection and ranging (LIDAR) systems also record “intensity”, loosely defined as the strength of the backscattered echo for each measured point. To date, LIDAR intensity data have proven beneficial in a wide range of applications because they are related to surface parameters, such as reflectance. While numerous procedures have been introduced in the scientific literature, and even commercial software, to enhance the utility of intensity data through a variety of “normalization”, “correction”, or “calibration” techniques, the current situation is complicated by a lack of standardization, as well as confusing, inconsistent use of terminology. In this paper, we first provide an overview of basic principles of LIDAR intensity measurements and applications utilizing intensity information from terrestrial, airborne topographic, and airborne bathymetric LIDAR. Next, we review effective parameters on intensity measurements, basic theory, and current intensity processing methods. We define terminology adopted from the most commonly-used conventions based on a review of current literature. Finally, we identify topics in need of further research. Ultimately, the presented information helps lay the foundation for future standards and specifications for LIDAR radiometric calibration. PMID:26561813

  12. A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration.

    PubMed

    Kashani, Alireza G; Olsen, Michael J; Parrish, Christopher E; Wilson, Nicholas

    2015-11-06

    In addition to precise 3D coordinates, most light detection and ranging (LIDAR) systems also record "intensity", loosely defined as the strength of the backscattered echo for each measured point. To date, LIDAR intensity data have proven beneficial in a wide range of applications because they are related to surface parameters, such as reflectance. While numerous procedures have been introduced in the scientific literature, and even commercial software, to enhance the utility of intensity data through a variety of "normalization", "correction", or "calibration" techniques, the current situation is complicated by a lack of standardization, as well as confusing, inconsistent use of terminology. In this paper, we first provide an overview of basic principles of LIDAR intensity measurements and applications utilizing intensity information from terrestrial, airborne topographic, and airborne bathymetric LIDAR. Next, we review effective parameters on intensity measurements, basic theory, and current intensity processing methods. We define terminology adopted from the most commonly-used conventions based on a review of current literature. Finally, we identify topics in need of further research. Ultimately, the presented information helps lay the foundation for future standards and specifications for LIDAR radiometric calibration.

  13. Technical note on the validation of a semi-automated image analysis software application for estrogen and progesterone receptor detection in breast cancer

    PubMed Central

    2011-01-01

    Background The immunohistochemical detection of estrogen (ER) and progesterone (PR) receptors in breast cancer is routinely used for prognostic and predictive testing. Whole slide digitalization supported by dedicated software tools allows quantization of the image objects (e.g. cell membrane, nuclei) and an unbiased analysis of immunostaining results. Validation studies of image analysis applications for the detection of ER and PR in breast cancer specimens provided strong concordance between the pathologist's manual assessment of slides and scoring performed using different software applications. Methods The effectiveness of two connected semi-automated image analysis software (NuclearQuant v. 1.13 application for Pannoramic™ Viewer v. 1.14) for determination of ER and PR status in formalin-fixed paraffin embedded breast cancer specimens immunostained with the automated Leica Bond Max system was studied. First the detection algorithm was calibrated to the scores provided an independent assessors (pathologist), using selected areas from 38 small digital slides (created from 16 cases) containing a mean number of 195 cells. Each cell was manually marked and scored according to the Allred-system combining frequency and intensity scores. The performance of the calibrated algorithm was tested on 16 cases (14 invasive ductal carcinoma, 2 invasive lobular carcinoma) against the pathologist's manual scoring of digital slides. Results The detection was calibrated to 87 percent object detection agreement and almost perfect Total Score agreement (Cohen's kappa 0.859, quadratic weighted kappa 0.986) from slight or moderate agreement at the start of the study, using the un-calibrated algorithm. The performance of the application was tested against the pathologist's manual scoring of digital slides on 53 regions of interest of 16 ER and PR slides covering all positivity ranges, and the quadratic weighted kappa provided almost perfect agreement (κ = 0.981) among the two

  14. Time-Series Hyperspectral and Multi-spectral Radiometric Measurements at the Martha's Vineyard Coastal Observatory

    NASA Astrophysics Data System (ADS)

    Lohrenz, S. E.; Sosik, H. M.; Crockford, E. T.; Chakraborty, S.

    2016-02-01

    High frequency temporal measurements are critical to resolving processes in dynamic coastal environments and geo-stationary satellites enable multiple observations over the course of a day. Such temporal resolution will be important in understanding rapid evolution of coastal physical processes (e.g., tides, wind forcing, water mass movement) as well as short-term changes in biological and chemical properties. The GEO-CAPE (Geostationary Coastal and Air Pollution Events) is one of 17 priority missions identified in the National Research Council's Earth Science Decadal Survey and will provide high spatial and temporal resolution observations of tropospheric trace gases and aerosols and coastal ocean phytoplankton, water quality and biogeochemistry. At present, however there are a limited number of hyperspectral ocean color observations in coastal waters and even fewer time-series observations. Such data sets, particularly when coupled with supporting optical and water property observations, would be highly beneficial in evaluating sensor requirements and algorithm performance. Here, we describe results of comparisons of hyperspectral and multi-spectral radiometric observations deployed at a cabled coastal ocean observatory on the New England continental shelf, the Martha's Vineyard Coastal Observatory (MVCO). The radiometric measurements are complemented by a broad suite of meteorological and hydrographic core measurements as well as efforts providing detailed characterization of changes in phytoplankton community structure with automated submersible flow cytometry and in-water optical properties (chl fluorescence, CDOM fluorescence, backscattering). Our findings illustrate the dynamic nature of this coastal ecosystem and the utility of hyperspectral radiometry and geostationary satellite observations to characterize short term variability in optical and biogeochemical properties of coastal environments.

  15. The Importance of Post-Launch, On-Orbit Absolute Radiometric Calibration for Remote Sensing Applications

    NASA Astrophysics Data System (ADS)

    Kuester, M. A.

    2015-12-01

    Remote sensing is a powerful tool for monitoring changes on the surface of the Earth at a local or global scale. The use of data sets from different sensors across many platforms, or even a single sensor over time, can bring a wealth of information when exploring anthropogenic changes to the environment. For example, variations in crop yield and health for a specific region can be detected by observing changes in the spectral signature of the particular species under study. However, changes in the atmosphere, sun illumination and viewing geometries during image capture can result in inconsistent image data, hindering automated information extraction. Additionally, an incorrect spectral radiometric calibration will lead to false or misleading results. It is therefore critical that the data being used are normalized and calibrated on a regular basis to ensure that physically derived variables are as close to truth as is possible. Although most earth observing sensors are well-calibrated in a laboratory prior to launch, a change in the radiometric response of the system is inevitable due to thermal, mechanical or electrical effects caused during the rigors of launch or by the space environment itself. Outgassing and exposure to ultra-violet radiation will also have an effect on the sensor's filter responses. Pre-launch lamps and other laboratory calibration systems can also fall short in representing the actual output of the Sun. A presentation of the differences in the results of some example cases (e.g. geology, agriculture) derived for science variables using pre- and post-launch calibration will be presented using DigitalGlobe's WorldView-3 super spectral sensor, with bands in the visible and near infrared, as well as in the shortwave infrared. Important defects caused by an incomplete (i.e. pre-launch only) calibration will be discussed using validation data where available. In addition, the benefits of using a well-validated surface reflectance product will be

  16. Research Libraries--Automation and Cooperation.

    ERIC Educational Resources Information Center

    McDonald, David R.; Hurowitz, Robert

    1982-01-01

    Description of Research Libraries Information Network, an automated technical processing and information retrieval system, notes subsystems (acquisitions, cataloging, message, print, tables), functions, design, and benefits to participating libraries. (Request complimentary subscription on institution letterhead from Editor, "Perspectives in…

  17. How to Evaluate Integrated Library Automation Systems.

    ERIC Educational Resources Information Center

    Powell, James R.; Slach, June E.

    1985-01-01

    This paper describes methodology used in compiling a list of candidate integrated library automation systems at a corporate technical library. Priorities for automation, identification of candidate systems, the filtering process, information for suppliers, software and hardware considerations, on-site evaluations, and final system selection are…

  18. How to Evaluate Integrated Library Automation Systems.

    ERIC Educational Resources Information Center

    Powell, James R.; Slach, June E.

    1985-01-01

    This paper describes methodology used in compiling a list of candidate integrated library automation systems at a corporate technical library. Priorities for automation, identification of candidate systems, the filtering process, information for suppliers, software and hardware considerations, on-site evaluations, and final system selection are…

  19. Technical and clinical evaluation of the VITROS® Immunodiagnostic Products 25-OH Vitamin D Total Assay--comparison with marketed automated immunoassays and a liquid chromatography-tandem mass spectrometry method.

    PubMed

    Cavalier, Etienne; Rousselle, Olivier; Ferrante, Nunzio; Carlisi, Agnes; Le Goff, Caroline; Souberbielle, Jean-Claude

    2013-10-01

    The study was conducted to evaluate the technical and clinical performance of the VITROS® Immunodiagnostic Products 25-OH Vitamin D Total Assay, and compare it with the performance of five marketed automated assays and a liquid chromatography/mass spectrometry reference method (LC-MS/MS). Three hundred patient serum samples were used to compare the correlation of the VITROS® 25-OH Vitamin D Total Assay with both the other immunoassays and the LC-MS/MS method, using Passing-Bablok regression and Bland-Altman analyses. Concordance of the diagnosis of vitamin D status was calculated to test the agreement between the different assays. In addition, samples containing vitamin D2 were used to test the assay's ability to detect the D2 form of the vitamin. These results from the VITROS® 25-OH Vitamin D Total Assay generally correlated well with those from most of the marketed immunoassays. Cross-reactivity of the D2 form was calculated as being close to 100%. Additionally, we found substantial variability in performance amongst the various assays, which suggests the need for optimisation and recalibration of commercial methods.

  20. Characterization of radiometric calibration of LANDSAT-4 TM reflective bands

    NASA Technical Reports Server (NTRS)

    Barker, J. L.; Abrams, R. B.; Ball, D. L.; Leung, K. C.

    1984-01-01

    Prelaunch and postlaunch internal calibrator, image, and background data is to characterize the radiometric performance of the LANDSAT-4 TM and to recommend improved procedures for radiometric calibration. All but two channels (band 2, channel 4; band 5, channel 3) behave normally. Gain changes relative to a postlaunch reference for channels within a band vary within 0.5 percent as a group. Instrument gain for channels in the cold focal plane oscillates. Noise in background and image data ranges from 0.5 to 1.7 counts. Average differences in forward and reverse image data indicate a need for separate calibration processing of forward and reverse scans. Precision is improved by increasing the pulse integration width from 31 to 41 minor frames, depending on the band.

  1. Issues in Absolute Spectral Radiometric Calibration: Intercomparison of Eight Sources

    NASA Technical Reports Server (NTRS)

    Goetz, Alexander F. H.; Kindel, Bruce; Pilewskie, Peter

    1998-01-01

    The application of atmospheric models to AVIRIS and other spectral imaging data to derive surface reflectance requires that the sensor output be calibrated to absolute radiance. Uncertainties in absolute calibration are to be expected, and claims of 92% accuracy have been published. Measurements of accurate surface albedos and cloud absorption to be used in radiative balance calculations depend critically on knowing the absolute spectral-radiometric response of the sensor. The Earth Observing System project is implementing a rigorous program of absolute radiometric calibration for all optical sensors. Since a number of imaging instruments that provide output in terms of absolute radiance are calibrated at different sites, it is important to determine the errors that can be expected among calibration sites. Another question exists about the errors in the absolute knowledge of the exoatmospheric spectral solar irradiance.

  2. SLC-off Landsat-7 ETM+ reflective band radiometric calibration

    USGS Publications Warehouse

    Markham, B.L.; Barsi, J.A.; Thome, K.J.; Barker, J.L.; Scaramuzza, P.L.; Helder, D.L.; ,

    2005-01-01

    Since May 31, 2003, when the scan line corrector (SLC) on the Landsat-7 ETM+ failed, the primary foci of Landsat-7 ETM+ analyses have been on understanding and attempting to fix the problem and later on developing composited products to mitigate the problem. In the meantime, the Image Assessment System personnel and vicarious calibration teams have continued to monitor the radiometric performance of the ETM+ reflective bands. The SLC failure produced no measurable change in the radiometric calibration of the ETM+ bands. No trends in the calibration are definitively present over the mission lifetime, and, if present, are less than 0.5% per year. Detector 12 in Band 7 dropped about 0.5% in response relative to the rest of the detectors in the band in May 2004 and recovered back to within 0.1% of its initial relative gain in October 2004.

  3. The 90 GHz radiometric imaging. [for terrain analysis

    NASA Technical Reports Server (NTRS)

    King, H. E.; White, J. D.; Wilson, W. J.; Mori, T. T.; Hollinger, J. P.; Troy, B. E.; Kenney, J. E.; Mcgoogan, J. T.

    1976-01-01

    A 90-GHz (3 mm wavelength) radiometer with a noise output fluctuation of 0.22 K (RMS), with a scanning antenna beam mirror, and the data processing system are described. Real-time radiometric imaging of terrain and man-made objects are shown. Flying at an altitude of 1500 ft a radiometer antenna with a 2 degrees halfpower beamwidth can distinguish landforms, waterways, roads, runways, bridges, ships at sea and their wakes, aircraft on runways, and athletic fields. A flight taken at an altitude of 3000 ft with approximately 2000 ft of clouds below the radiometer demonstrates the ability to distinguish bridges, rivers, marshland and other landforms even though the clouds are optically opaque. The radiometric images of a few representative scenes along with photographs of the corresponding scenes are presented to demonstrate the resolution of the imager system.

  4. Development and calibration of UV/VUV radiometric sources

    NASA Technical Reports Server (NTRS)

    Bridges, J. M.

    1993-01-01

    A program exists at NIST to calibrate radiometric sources for the spectral range from 118-350 nm. These include deuterium lamps, hollow-cathode lamps, RF-excited dimer lamps, and wall-stabilized argon arcs. Sources have been calibrated for and used by researchers in solar physics, astrophysics, atmospheric physics (ozone measurements), magnetically controlled fusion, and photobiology. The argon arcs were developed in our laboratory, and provide intense sources of both radiance and irradiance. Calibrations are performed relative to two primary sources, a wall-stabilized hydrogen arc and a 12,000 K black-body line arc, both developed in our laboratory. Also we recently have begun periodic calibrations on the NIST storage ring, SURF II, to insure consistency between our respective radiometric bases. Various sources have been calibrated for space' applications, including several which are flyable. Also, some development and testing of radiometers for semiconductor lithography were recently carried out with an intense argon arc source.

  5. Calibration transfer target for a microwave radiometric profiling system

    NASA Astrophysics Data System (ADS)

    Jordan, J.; Decker, M.

    1990-11-01

    The Wave Propagation Laboratory has been operating a six-channel radiometer profiler since 1981 at Stapleton International Airport in Denver, Colorado, to retrieve temperature profiles. The atmospheric absorption at these frequencies is too large for tipping calibrations to be used. Therefore, data from collocated National Weather Service radiosondes were used to calibrate the radiometric profiles. The technique provides the necessary profiler calibration but limits its use to locations with regular radiosonde launches. Therefore, a prototype calibration transfer target was constructed at Stapleton Airport to demonstrate the feasibility of using the target to help maintain a network of radiometric profilers not located at radiosonde sites. The calibration target is described, along with potential error sources.

  6. Application of a scattered-light radiometric power meter.

    PubMed

    Caron, James N; DiComo, Gregory P; Ting, Antonio C; Fischer, Richard P

    2011-04-01

    The power measurement of high-power continuous-wave laser beams typically calls for the use of water-cooled thermopile power meters. Large thermopile meters have slow response times that can prove insufficient to conduct certain tests, such as determining the influence of atmospheric turbulence on transmitted beam power. To achieve faster response times, we calibrated a digital camera to measure the power level as the optical beam is projected onto a white surface. This scattered-light radiometric power meter saves the expense of purchasing a large area power meter and the required water cooling. In addition, the system can report the power distribution, changes in the position, and the spot size of the beam. This paper presents the theory of the scattered-light radiometric power meter and demonstrates its use during a field test at a 2.2 km optical range. © 2011 American Institute of Physics

  7. The OLI Radiometric Scale Realization Round Robin Measurement Campaign

    NASA Technical Reports Server (NTRS)

    Cutlip, Hansford; Cole,Jerold; Johnson, B. Carol; Maxwell, Stephen; Markham, Brian; Ong, Lawrence; Hom, Milton; Biggar, Stuart

    2011-01-01

    A round robin radiometric scale realization was performed at the Ball Aerospace Radiometric Calibration Laboratory in January/February 2011 in support of the Operational Land Imager (OLI) Program. Participants included Ball Aerospace, NIST, NASA Goddard Space Flight Center, and the University of Arizona. The eight day campaign included multiple observations of three integrating sphere sources by nine radiometers. The objective of the campaign was to validate the radiance calibration uncertainty ascribed to the integrating sphere used to calibrate the OLI instrument. The instrument level calibration source uncertainty was validated by quatnifying: (1) the long term stability of the NIST calibrated radiance artifact, (2) the responsivity scale of the Ball Aerospace transfer radiometer and (3) the operational characteristics of the large integrating sphere.

  8. Radiometric Methods for Rapid Diagnosis of Viral Infection.

    DTIC Science & Technology

    1975-11-01

    4, 6, 24, 48, and 72 hours postinfection, infection time beginning when the 14C-labeled medium was added. Nucleic acid sT, thesis system. Stationary...coccus epidermidis, Pseudomonas aeruginosa, and Acinetobacter caloaceticus var. anitratus) had no effect on the DNA synthesis of HSV-1 infected or...7 UNCLASS 41 RADIOMETRIC METHODS FOR RAPID DIAGNIS F VIRA ~ /fl INFECTION (U) JOHNS HOPKINS UNIV BALTIMORE MDUNC . IFEDH N WAG ER FT AL. NOV 75

  9. Radiometric measurements of gap probability in conifer tree canopies

    NASA Technical Reports Server (NTRS)

    Albers, Bryan J.; Strahler, Alan H.; Li, Xiaowen; Liang, Shunlin; Clarke, Keith C.

    1990-01-01

    Measurements of gap probability were made for some moderate-sized, open-grown conifers of varying species. Results of the radiometric analysis show that the gap probability, which is taken as the mean of the binomial, fits well a negative exponential function of a path length. The conifer shadow, then, is an object of almost uniform darkness with some bright holes or gaps that are found near the shadow's edge and rapidly disappear toward the shadows center.

  10. Radiometric observations of the nucleus of Comet Halley

    NASA Technical Reports Server (NTRS)

    Delamere, W. A.; Reitsema, H. J.; Huebner, W. F.; Schmidt, H. U.; Keller, H. U.; Schmidt, W. K. H.; Wilhelm, K.; Whipple, Fred L.

    1986-01-01

    Images obtained by the Halley multicolor camera (HMC) were used to determine the surface brightness of the nucleus. Radiometric values of jet-free areas of the surface are presented and a range of possible surface brightness values are derived. These direct measures are compared with brightnesses derived from the size of the nucleus, as determined from HMC images, and ground-based observations obtained before the onset of coma activity.

  11. Novel techniques for the analysis of the TOA radiometric uncertainty

    NASA Astrophysics Data System (ADS)

    Gorroño, Javier; Banks, Andrew; Gascon, Ferran; Fox, Nigel P.; Underwood, Craig I.

    2016-10-01

    In the framework of the European Copernicus programme, the European Space Agency (ESA) has launched the Sentinel-2 (S2) Earth Observation (EO) mission which provides optical high spatial -resolution imagery over land and coastal areas. As part of this mission, a tool (named S2-RUT, from Sentinel-2 Radiometric Uncertainty Tool) estimates the radiometric uncertainties associated to each pixel using as input the top-of-atmosphere (TOA) reflectance factor images provided by ESA. The initial version of the tool has been implemented — code and user guide available1 — and integrated as part of the Sentinel Toolbox. The tool required the study of several radiometric uncertainty sources as well as the calculation and validation of the combined standard uncertainty in order to estimate the TOA reflectance factor uncertainty per pixel. Here we describe the recent research in order to accommodate novel uncertainty contributions to the TOA reflectance uncertainty estimates in future versions of the tool. The two contributions that we explore are the radiometric impact of the spectral knowledge and the uncertainty propagation of the resampling associated to the orthorectification process. The former is produced by the uncertainty associated to the spectral calibration as well as the spectral variations across the instrument focal plane and the instrument degradation. The latter results of the focal plane image propagation into the provided orthoimage. The uncertainty propagation depends on the radiance levels on the pixel neighbourhood and the pixel correlation in the temporal and spatial dimensions. Special effort has been made studying non-stable scenarios and the comparison with different interpolation methods.

  12. LANDSAT-4 multispectral scanner (MSS) subsystem radiometric characterization

    NASA Technical Reports Server (NTRS)

    Alford, W. (Editor); Barker, J. (Editor); Clark, B. P.; Dasgupta, R.

    1983-01-01

    The multispectral band scanner (mass) and its spectral characteristics are described and methods are given for relating video digital levels on computer compatible tapes to radiance into the sensor. Topics covered include prelaunch calibration procedures and postlaunch radiometric processng. Examples of current data resident on the MSS image processing system are included. The MSS on LANDSAT 4 is compared with the scanners on earlier LANDSAT satellites.

  13. High speed radiometric measurements of IED detonation fireballs

    NASA Astrophysics Data System (ADS)

    Spidell, Matthew T.; Gordon, J. Motos; Pitz, Jeremey; Gross, Kevin C.; Perram, Glen P.

    2010-04-01

    Continuum emission is predominant in fireball spectral phenomena and in some demonstrated cases, fine detail in the temporal evolution of infrared spectral emissions can be used to estimate size and chemical composition of the device. Recent work indicates that a few narrow radiometric bands may reveal forensic information needed for the explosive discrimination and classification problem, representing an essential step in moving from "laboratory" measurements to a rugged, fieldable system. To explore phenomena not observable in previous experiments, a high speed (10μs resolution) radiometer with four channels spanning the infrared spectrum observed the detonation of nine home made explosive (HME) devices in the < 100lb class. Radiometric measurements indicate that the detonation fireball is well approximated as a single temperature blackbody at early time (0 < t <~ 3ms). The effective radius obtained from absolute intensity indicates fireball growth at supersonic velocity during this time. Peak fireball temperatures during this initial detonation range between 3000.3500K. The initial temperature decay with time (t <~ 10ms) can be described by a simple phenomenological model based on radiative cooling. After this rapid decay, temperature exhibits a small, steady increase with time (10 <~ t <~ 50ms) and peaking somewhere between 1000.1500K-likely the result of post-detonation combustion-before subsequent cooling back to ambient conditions . Radius derived from radiometric measurements can be described well (R2 > 0.98) using blast model functional forms, suggesting that energy release could be estimated from single-pixel radiometric detectors. Comparison of radiometer-derived fireball size with FLIR infrared imagery indicate the Planckian intensity size estimates are about a factor of two smaller than the physical extent of the fireball.

  14. Changes in the Radiometric Sensitivity of SeaWiFS

    NASA Technical Reports Server (NTRS)

    McClain, Charles R.; Barnes, Robert A.; Eplee, Robert E., Jr.; Patt, Frederick S.

    1998-01-01

    We report on the lunar and solar measurements used to determine the changes in the radiometric sensitivity of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS). Radiometric sensitivity is defined as the output from the instrument (or from one of the instrument bands) per unit spectral radiance at the instrument's input aperture. Knowledge of the long-term repeatability of the SeaWiFS measurements is crucial to maintaining the quality of the ocean scenes derived from measurements by the instrument. For SeaWiFS bands 1 through 6 (412 nm through 670 rim), the change in radiometric sensitivity is less than 0.2% for the period from November 1997 through November 1998. For band 7 (765 nm), the change is about 1.5%, and for band 8 (865 nm) about 5%. The rates of change of bands 7 and 8, which were linear with time for the first eight months of lunar measurements, are now slowing. The scatter in the data points about the trend lines in this analysis is less than 0.3% for all eight SeaWiFS bands. These results are based on monthly measurements of the moon. Daily solar measurements using an onboard diffuser show that the radiometric sensitivities of the SeaWiFS bands have changed smoothly during the time intervals between lunar measurements. Since SeaWiFS measurements have continued past November 1998, the results presented here are considered as a snapshot of the instrument performance as of that date.

  15. Analysis and Applications of Radiometric Forces in Rarefied Gas Flows

    DTIC Science & Technology

    2010-06-16

    Forces in Rarefied Gas Flows 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Sergey F. Gimelshein & Natalia E. Gimelshein (ERC, Inc...Forces in Rarefied Gas Flows Sergey F. Gimelshein∗, Natalia E. Gimelshein∗, Andrew D. Ketsdever† and Nathaniel P. Selden∗∗ ∗ERC, Inc, Edwards AFB, CA 93524...geometries. Keywords: Radiometric force, shear, ES-BGK equation PACS: 51.10.+y INTRODUCTION Rarefied gas flow surrounding a thin vane with a temperature

  16. The Radiometric Bode’s law and Extrasolar Planets

    DTIC Science & Technology

    2004-09-01

    THE RADIOMETRIC BODE’S LAW AND EXTRASOLAR PLANETS T. Joseph, W. Lazio Naval Research Laboratory, Code 7213, Washington, DC 20375-5351; joseph.lazio...the magnetic polar regions. We find that most of the known extrasolar planets should emit in the frequency range 10–1000 MHz and, under favorable...detect the known extrasolar planets or place austere limits on their radio emission. Planets with masses much lower than those in the current census

  17. BOREAS TE-18, 60-m, Radiometrically Rectified Landsat TM Imagery

    NASA Technical Reports Server (NTRS)

    Hall, Forrest G. (Editor); Knapp, David

    2000-01-01

    The BOREAS TE-18 team used a radiometric rectification process to produce standardized DN values for a series of Landsat TM images of the BOREAS SSA and NSA in order to compare images that were collected under different atmospheric conditions. The images for each study area were referenced to an image that had very clear atmospheric qualities. The reference image for the SSA was collected on 02-Sep-1994, while the reference image for the NSA was collected on 2 1 Jun-1995. The 23 rectified images cover the period of 07-Jul-1985 to 18-Sep-1994 in the SSA and 22-Jun-1984 to 09-Jun-1994 in the NSA. Each of the reference scenes had coincident atmospheric optical thickness measurements made by RSS-11. The radiometric rectification process is described in more detail by Hall et al. (1991). The original Landsat TM data were received from CCRS for use in the BOREAS project. Due to the nature of the radiometric rectification process and copyright issues, the full-resolution (30-m) images may not be publicly distributed. However, this spatially degraded 60-m resolution version of the images may be openly distributed and is available on the BOREAS CD-ROM series. After the radiometric rectification processing, the original data were degraded to a 60-m pixel size from the original 30-m pixel size by averaging the data over a 2- by 2-pixel window. The data are stored in binary image-format files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Activity Archive Center (DAAC).

  18. Automation or De-automation

    NASA Astrophysics Data System (ADS)

    Gorlach, Igor; Wessel, Oliver

    2008-09-01

    In the global automotive industry, for decades, vehicle manufacturers have continually increased the level of automation of production systems in order to be competitive. However, there is a new trend to decrease the level of automation, especially in final car assembly, for reasons of economy and flexibility. In this research, the final car assembly lines at three production sites of Volkswagen are analysed in order to determine the best level of automation for each, in terms of manufacturing costs, productivity, quality and flexibility. The case study is based on the methodology proposed by the Fraunhofer Institute. The results of the analysis indicate that fully automated assembly systems are not necessarily the best option in terms of cost, productivity and quality combined, which is attributed to high complexity of final car assembly systems; some de-automation is therefore recommended. On the other hand, the analysis shows that low automation can result in poor product quality due to reasons related to plant location, such as inadequate workers' skills, motivation, etc. Hence, the automation strategy should be formulated on the basis of analysis of all relevant aspects of the manufacturing process, such as costs, quality, productivity and flexibility in relation to the local context. A more balanced combination of automated and manual assembly operations provides better utilisation of equipment, reduces production costs and improves throughput.

  19. Space station automation study: Autonomous systems and assembly, volume 2

    NASA Technical Reports Server (NTRS)

    Bradford, K. Z.

    1984-01-01

    This final report, prepared by Martin Marietta Denver Aerospace, provides the technical results of their input to the Space Station Automation Study, the purpose of which is to develop informed technical guidance in the use of autonomous systems to implement space station functions, many of which can be programmed in advance and are well suited for automated systems.

  20. Laboratory-Based BRDF Calibration of Radiometric Tarps

    NASA Technical Reports Server (NTRS)

    Georgiev, Georgi T.; Butler, James J.

    2007-01-01

    The current study provides the remote sensing community with important high accuracy laboratory-based BRDF calibration of radiometric tarps. The results illustrate the dependence of tarps' weft and warp threads orientation on BRDF. The study was done at incident angles of 0deg, 10deg, and 30deg; scatter zenith angles from 0deg to 60deg, and scatter azimuth angles of 0deg, 45deg, 90deg, 135deg, and 180deg. The wavelengths were 485nm, 550nm, 633nm and 800nm. The dependence is well defined at all measurement geometries and wavelengths. It can be as high as 8% at 0deg incident angle and 2% at 30deg incident angle. The fitted BRDF data show a very small discrepancy from the measured ones. New data on the forward and backscatter properties of radiometric tarps is reported. The backward scatter is well pronounced for the white samples. The black sample has well pronounced forward scatter. The BRDF characterization of radiometric tarps can be successfully extended to other structured surface fabric samples. The results are NIST traceable.

  1. User's guide to the Radiometric Age Data Bank (RADB)

    USGS Publications Warehouse

    Zartman, Robert Eugene; Cole, James C.; Marvin, Richard F.

    1976-01-01

    The Radiometric Age Data Bank (RADB) has been established by the U.S. Geological Survey, as a means for collecting and organizing the estimated 100,000 radiometric ages presently published for the United States. RADB has been constructed such that a complete sample description (location, rock type, etc.), literature citation, and extensive analytical data are linked to form an independent record for each sample reported in a published work. Analytical data pertinent to the potassium-argon, rubidium-strontium, uranium-thorium-lead, lead-alpha, and fission-track methods can be accommodated, singly or in combinations, for each record. Data processing is achieved using the GIPSY program (University of Oklahoma) which maintains the data file and builds, updates, searches, and prints the records using simple yet versatile command statements. Searching and selecting records is accomplished by specifying the presence, absence, or (numeric or alphabetic) value of any element of information in the data bank, and these specifications can be logically linked to develop sophisticated searching strategies. Output is available in the form of complete data records, abbreviated tests, or columnar tabulations. Samples of data-reporting forms, GIPSY command statements, output formats, and data records are presented to illustrate the comprehensive nature and versatility of the Radiometric Age Data Bank.

  2. A Preliminary Analysis of LANDSAT-4 Thematic Mapper Radiometric Performance

    NASA Technical Reports Server (NTRS)

    Justice, C.; Fusco, L.; Mehl, W.

    1985-01-01

    The NASA raw (BT) product, the radiometrically corrected (AT) product, and the radiometrically and geometrically corrected (PT) product of a TM scene were analyzed examine the frequency distribution of the digital data; the statistical correlation between the bands; and the variability between the detectors within a band. The analyses were performed on a series of image subsets from the full scence. Results are presented from one 1024 c 1024 pixel subset of Realfoot Lake, Tennessee which displayed a representative range of ground conditions and cover types occurring within the full frame image. From this cursory examination of one of the first seven channel TM data sets, it would appear that the radiometric performance of the system is most satisfactory and largely meets pre-launch specifications. Problems were noted with Band 5 Detector 3 and Band 2 Detector 4. Differences were observed between forward and reverse scan detector responses both for the BT and AT products. No systematic variations were observed between odd and even detectors.

  3. Radiometric calibration of tempospatially modulated polarization interference imaging spectrometer.

    PubMed

    Gao, Peng; Ai, Jingjing; Zhang, Chunmin

    2016-12-10

    The tempospatially modulated polarization interference imaging spectrometer (TSMPIIS) nominated by the Ministry of Scence and Technology, takes part in the "Eleventh Five-Year National Science and Technology Exhibition." In order to improve the detecting precision of the TSMPIIS, its radiometric calibration scheme is proposed on the basis of the solar simulator, integrating sphere, monochromator, and spectroradiometer. Under the conditions of changing the exposure time and radiant brightness, the CCD linear responses for the TSMPIIS were first tested to validate the reliability of the radiometric calibration performed with a linear response model, and the linear errors were less than 0.15% and 1.15%, respectively. A novel method is put forward to calibrate the nonuniformity of CCD pixels, and the least squares method can commendably correct the uneven effect in the spatial direction. Besides, the absolute radiometric calibration establishes a corresponding relation between the dimensionless intensity output from the TSMPIIS and the target radiant brightness. The study lays the foundation for the engineering application of the TSMPIIS, such as remote sensing detection, and has an important significance for the development of our instrument and equipment technology with independent intellectual property rights.

  4. Detection of mycobacteria by radiometric and standard plate procedures.

    PubMed Central

    Damato, J J; Collins, M T; Rothlauf, M V; McClatchy, J K

    1983-01-01

    A group of 89 smear-positive sputum specimens were evaluated by radiometric and standard plate procedures to determine the methodology which would provide the earliest detection of mycobacteria and maximum test sensitivity. Digested non-decontaminated specimens were concentrated and inoculated into modified selective BACTEC radiometric 7H12 broth and Mitchison selective 7H10 agar. Sodium hydroxide (1.5% final concentration) was then used to decontaminate these specimens. They were then concentrated and inoculated into both selective and nonselective 7H12 radiometric broths and into selective 7H10 and nonselective Middlebrook 7H11 agar media. The specimen processing and media combinations providing the earliest detection were non-decontaminated specimens with modified selective 7H12 BACTEC broth and decontaminated specimens with 7H12 BACTEC broths. Maximum sensitivity (percent positive) was obtained by using non-decontaminated specimens on Mitchison selective 7H10 Agar (98%) or decontaminated specimens in 7H12 BACTEC broth (95%). The decontamination process was found to reduce significantly the number of mycobacteria in clinical specimens, particularly the mycobacteria other than Mycobacterium tuberculosis. The specimen processing-media combinations providing the earliest detection and maximum recovery of mycobacteria (100%) were non-decontaminated specimens with modified selective 7H12 BACTEC broth or Mitchison selective agar and decontaminated specimens with 7H12 BACTEC broth or 7H11 agar. PMID:6348076

  5. Granite petrogenesis revealed by combined gravimetric and radiometric imaging

    NASA Astrophysics Data System (ADS)

    Tartèse, Romain; Boulvais, Philippe; Poujol, Marc; Vigneresse, Jean-Louis

    2011-03-01

    In peneplaned terranes, it is often impossible to get a full 3D view of geological objects. In the case of granitic plutons, for which intrusive relationships between constituent units can provide first order information regarding their petrogenesis, this lack of 3D field evidence is a major issue. Indirect observations can be provided by geophysical surveys. Here, we interpret field gravity data and airborne gamma ray radiometric maps with whole rock geochemistry data in order to obtain information on granite petrogenesis. First, we test our proposed combined geophysical and geochemical approach on the Huelgoat Variscan intrusion (Armorican Massif, France) and we show that ternary radiometric maps are a good proxy for the distribution of K, U and Th radioelements. Then, we apply our method to the Lizio and Questembert Variscan granitic intrusions (Armorican Massif) and show that some features characteristic of the intrusions, such as the feeding zones, can be localised by geophysical imaging. Indeed, radiometric maps constitute a frozen image of the latest stage of the magmatic building of plutons.

  6. Radiometric cross-calibration of KOMPSAT-3 with Landsat-8

    NASA Astrophysics Data System (ADS)

    Shin, Dongyoon; Jin, Cheonggil; Ahn, Hoyong; Choi, Chuluong

    2015-10-01

    This paper presents a radiometric cross calibration of KOMPSAT-3 AEISS based on Landsat-8 OLI. Cross calibration between the two sensors using simultaneous image pairs, acquired during an underfly event over the Libya 4 pseudo invariant calibration site (PICS) site. The spectral profile of the target comes from the near-simultaneous EO-1 Hyperion data over these sites for apply Spectral Band Adjustment Factor (SBAF). The results indicate that the Top Of Atmosphere (TOA) reflectance measurements for KOMPSAT-3 agree with Landsat-8 to within 5% after the application of SBAF. To validate radiometric coefficient, comparison TOA reflectance executed in north Virginia, USA. The difference in TOA reflectance was calculated to within a maximum ±1.55%. There was a huge improvement when the standard deviation altered from 0.1 to 0.01, when applying the SBAF. The result of radiometric coefficient presented here appear to be a good standard for maintaining the optical quality of the KOMPSAT-3, for which prelaunch, onboard, and vicarious calibration data are lacking.

  7. Preliminary radiometric calibration assessment of ALOS AVNIR-2

    USGS Publications Warehouse

    Bouvet, M.; Goryl, P.; Chander, G.; Santer, R.; Saunier, S.

    2008-01-01

    This paper summarizes the activities carried out in the frame of the data quality activities of the Advanced Visible and Near Infrared Radiometer type 2 (AVNIR-2) sensor onboard the Advanced Land Observing Satellite (ALOS). Assessment of the radiometric calibration of the AVNIR-2 multi-spectral imager is achieved via three intercomparisons to currently flying sensors over the Libyan desert, during the first year of operation. AU three methodologies indicate a slight underestimation of AVNIR-2 in band 1 by 4 to 7% with respect to other sensors radiometric scale. Band 2 does not show any obvious bias. Results for band 3 are affected by saturation due to inappropriate gain setting. Two methodologies indicate no significant bias in band 4. Preliminary results indicate possible degradations of the AVNIR-2 channels, which, when modeled as an exponentially decreasing functions, have time constants of respectively 13.2 %.year-1, 8.8%.year-1 and 0.1%.year-1 in band 1, 2 and 4 (with respect to the radiometric scale of the MEdium Resolution Imaging Spectrometer, MERIS). Longer time series of AVNIR-2 data are needed to draw final conclusions. ?? 2007 IEEE.

  8. On the estimation of snow depth from microwave radiometric measurements

    NASA Technical Reports Server (NTRS)

    Wang, James R.; Chang, Alfred T. C.; Sharma, Awdhesh K.

    1992-01-01

    Multiple-channel microwave radiometric measurements made over Alaska at aircraft (near 90 and 183 GHz) and satellite (at 37 and 85 GHz) altitudes are used to study the effect of atmospheric absorption on the estimation of snow depth. The estimation is based on the radiative transfer calculations using an early theoretical model of Mie scattering of single-size particles. It is shown that the radiometric correction for the effect of atmospheric absorption is important even at 37 GHz for a reliable estimation of snow depth. Under a dry atmosphere and based on single-frequency radiometric measurements, the underestimation of snow depth could amount to 50 percent at 85 GHz and 20-30 percent at 37 GHz if the effect of atmospheric absorption is not taken into account. The snow depths estimated from the 90-GHz aircraft and 85-GHz satellite measurements are found to be in reasonable agreement. However, there is a discrepancy in the snow depths estimated from the 37-GHz (at both vertical and horizontal polarizations) and 85-GHz satellite measurements.

  9. Results of magnetic HGI and radiometric surveys in W. Canada

    SciTech Connect

    LeSchack, L.A.

    1997-05-19

    This article presents four case histories in which ground-based magnetic horizontal gradient intensity (HGI) and radiometric surveys were used in Western Canada for cost-effective geochemical exploration for hydrocarbons. The authors has developed these two surface exploration techniques from published studies and adapted them for use on the prairies the past 7 years. These surveys are used in conjunction with the usual geologic and seismic studies for: (1) evaluating prospects and land; (2) verifying seismic anomalies and inexpensively locating areas for conducting expensive 3D seismic surveys. Occasionally, as in two of the case histories discussed, these surveys were used successfully as stand-alone exploration methods where seismic exploration is not effective. The HGI and radiometric surveys measure, by geophysical methods, those effects associated with geochemical alterations due to vertical microseepage of hydrocarbons. The total cost, including permitting, data acquisition, data processing, and interpretation of the combination HGI and radiometric surveys is about 15% the total cost of a 3D seismic survey. Because of this, the author finds them an attractive and rapid survey adjunct to traditional exploration. They substantially reduce finding costs and significantly raise the probability of financial success.

  10. Radiometric, geometric, and image quality assessment of ALOS AVNIR-2 and PRISM sensors

    USGS Publications Warehouse

    Saunier, S.; Goryl, P.; Chander, G.; Santer, R.; Bouvet, M.; Collet, B.; Mambimba, A.; Kocaman, Aksakal S.

    2010-01-01

    The Advanced Land Observing Satellite (ALOS) was launched on January 24, 2006, by a Japan Aerospace Exploration Agency (JAXA) H-IIA launcher. It carries three remote-sensing sensors: 1) the Advanced Visible and Near-Infrared Radiometer type 2 (AVNIR-2); 2) the Panchromatic Remote-Sensing Instrument for Stereo Mapping (PRISM); and 3) the Phased-Array type L-band Synthetic Aperture Radar (PALSAR). Within the framework of ALOS Data European Node, as part of the European Space Agency (ESA), the European Space Research Institute worked alongside JAXA to provide contributions to the ALOS commissioning phase plan. This paper summarizes the strategy that was adopted by ESA to define and implement a data verification plan for missions operated by external agencies; these missions are classified by the ESA as third-party missions. The ESA was supported in the design and execution of this plan by GAEL Consultant. The verification of ALOS optical data from PRISM and AVNIR-2 sensors was initiated 4 months after satellite launch, and a team of principal investigators assembled to provide technical expertise. This paper includes a description of the verification plan and summarizes the methodologies that were used for radiometric, geometric, and image quality assessment. The successful completion of the commissioning phase has led to the sensors being declared fit for operations. The consolidated measurements indicate that the radiometric calibration of the AVNIR-2 sensor is stable and agrees with the Landsat-7 Enhanced Thematic Mapper Plus and the Envisat MEdium-Resolution Imaging Spectrometer calibration. The geometrical accuracy of PRISM and AVNIR-2 products improved significantly and remains under control. The PRISM modulation transfer function is monitored for improved characterization.

  11. Preliminary Evaluation of the Radiometric Calibration of LANDSAT-4 Thematic Mapper Data by the Canada Centre for Remote Sensing

    NASA Technical Reports Server (NTRS)

    Murphy, J.; Park, W.; Fitzgerald, A.

    1985-01-01

    The radiometric characteristics of the LANDSAT-4 TM sensor are being studied with a view to developing absolute and relative radiometric calibration procedures. Preliminary results from several different approaches to the relative correction of all detectors within each band are reported. Topics covered include: the radiometric correction method; absolute calibration; the relative radiometric calibration algorithm; relative gain and offset calibration; relative gain and offset observations; and residual radiometric stripping.

  12. Transmittance measurement of a heliostat facility used in the preflight radiometric calibration of Earth-observing sensors

    NASA Astrophysics Data System (ADS)

    Czapla-Myers, J.; Thome, K.; Anderson, N.; McCorkel, J.; Leisso, N.; Good, W.; Collins, S.

    2009-08-01

    Ball Aerospace and Technologies Corporation in Boulder, Colorado, has developed a heliostat facility that will be used to determine the preflight radiometric calibration of Earth-observing sensors that operate in the solar-reflective regime. While automatically tracking the Sun, the heliostat directs the solar beam inside a thermal vacuum chamber, where the sensor under test resides. The main advantage to using the Sun as the illumination source for preflight radiometric calibration is because it will also be the source of illumination when the sensor is in flight. This minimizes errors in the pre- and post-launch calibration due to spectral mismatches. It also allows the instrument under test to operate at irradiance values similar to those on orbit. The Remote Sensing Group at the University of Arizona measured the transmittance of the heliostat facility using three methods, the first of which is a relative measurement made using a hyperspectral portable spectroradiometer and well-calibrated reference panel. The second method is also a relative measurement, and uses a 12-channel automated solar radiometer. The final method is an absolute measurement using a hyperspectral spectroradiometer and reference panel combination, where the spectroradiometer is calibrated on site using a solar-radiation-based calibration.

  13. Transmittance Measurement of a Heliostat Facility used in the Preflight Radiometric Calibration of Earth-Observing Sensors

    NASA Technical Reports Server (NTRS)

    Czapla-Myers, J.; Thome, K.; Anderson, N.; McCorkel, J.; Leisso, N.; Good, W.; Collins, S.

    2009-01-01

    Ball Aerospace and Technologies Corporation in Boulder, Colorado, has developed a heliostat facility that will be used to determine the preflight radiometric calibration of Earth-observing sensors that operate in the solar-reflective regime. While automatically tracking the Sun, the heliostat directs the solar beam inside a thermal vacuum chamber, where the sensor under test resides. The main advantage to using the Sun as the illumination source for preflight radiometric calibration is because it will also be the source of illumination when the sensor is in flight. This minimizes errors in the pre- and post-launch calibration due to spectral mismatches. It also allows the instrument under test to operate at irradiance values similar to those on orbit. The Remote Sensing Group at the University of Arizona measured the transmittance of the heliostat facility using three methods, the first of which is a relative measurement made using a hyperspectral portable spectroradiometer and well-calibrated reference panel. The second method is also a relative measurement, and uses a 12-channel automated solar radiometer. The final method is an absolute measurement using a hyperspectral spectroradiometer and reference panel combination, where the spectroradiometer is calibrated on site using a solar-radiation-based calibration.

  14. Technology modernization assessment flexible automation

    SciTech Connect

    Bennett, D.W.; Boyd, D.R.; Hansen, N.H.; Hansen, M.A.; Yount, J.A.

    1990-12-01

    The objectives of this report are: to present technology assessment guidelines to be considered in conjunction with defense regulations before an automation project is developed to give examples showing how assessment guidelines may be applied to a current project to present several potential areas where automation might be applied successfully in the depot system. Depots perform primarily repair and remanufacturing operations, with limited small batch manufacturing runs. While certain activities (such as Management Information Systems and warehousing) are directly applicable to either environment, the majority of applications will require combining existing and emerging technologies in different ways, with the special needs of depot remanufacturing environment. Industry generally enjoys the ability to make revisions to its product lines seasonally, followed by batch runs of thousands or more. Depot batch runs are in the tens, at best the hundreds, of parts with a potential for large variation in product mix; reconfiguration may be required on a week-to-week basis. This need for a higher degree of flexibility suggests a higher level of operator interaction, and, in turn, control systems that go beyond the state of the art for less flexible automation and industry in general. This report investigates the benefits and barriers to automation and concludes that, while significant benefits do exist for automation, depots must be prepared to carefully investigate the technical feasibility of each opportunity and the life-cycle costs associated with implementation. Implementation is suggested in two ways: (1) develop an implementation plan for automation technologies based on results of small demonstration automation projects; (2) use phased implementation for both these and later stage automation projects to allow major technical and administrative risk issues to be addressed. 10 refs., 2 figs., 2 tabs. (JF)

  15. Evaluation of an automated karyotyping system for chromosome aberration analysis

    NASA Technical Reports Server (NTRS)

    Prichard, Howard M.

    1987-01-01

    Chromosome aberration analysis is a promising complement to conventional radiation dosimetry, particularly in the complex radiation fields encountered in the space environment. The capabilities of a recently developed automated karyotyping system were evaluated both to determine current capabilities and limitations and to suggest areas where future development should be emphasized. Cells exposed to radiometric chemicals and to photon and particulate radiation were evaluated by manual inspection and by automated karyotyping. It was demonstrated that the evaluated programs were appropriate for image digitization, storage, and transmission. However, automated and semi-automated scoring techniques must be advanced significantly if in-flight chromosome aberration analysis is to be practical. A degree of artificial intelligence may be necessary to realize this goal.

  16. Microwave Radiometric Complex for Studying the Thermal Structure of the Earth's Atmosphere

    NASA Astrophysics Data System (ADS)

    Ryskin, V. G.; Shvetsov, A. A.; Kulikov, M. Yu.; Belikovich, M. V.; Bol'shakov, O. S.; Krasil'nikov, A. A.; Kukin, L. M.; Lesnov, I. V.; Skalyga, N. K.; Feigin, A. M.

    2017-01-01

    We describe a microwave radiometric complex intended for remote passive monitoring of the atmospheric temperatures from the Earth's surface. The complex consists of three spectroradiometers operating in a frequency range of 50-60 GHz, which covers the central part of the absorption band of molecular oxygen and its low-frequency slope. The radiometers have different spectral resolutions and allow one to simultaneously study the thermal structure of the surface air, the free troposphere, and the stratosphere. To ensure internal calibration of the intensity of the received atmospheric radiation, a built-in device of the modulator-calibrator type on the basis of the Schottky-barrier GaAs diodes is used. The complex is equipped with an automated system to control the measurement process, calibration, and preliminary data processing. Using the microwave sensing results, we intend to retrieve the atmospheric temperature profiles in an altitude interval of 0.05-55 km on the basis on the Bayesian approach to solving ill-posed inverse problems.

  17. High-throughput radiometric CYP2C19 inhibition assay using tritiated (S)-mephenytoin.

    PubMed

    Di Marco, Annalise; Cellucci, Antonella; Chaudhary, Ashok; Fonsi, Massimiliano; Laufer, Ralph

    2007-10-01

    A rapid and sensitive radiometric assay for assessing the potential of drugs to inhibit cytochrome P450 (P450) 2C19 in human liver microsomes is described. The new assay, which does not require high-performance liquid chromatography (HPLC) separation or mass spectrometric detection, is based on the release of tritium as tritiated water that occurs upon CYP2C19-mediated 4'-hydroxylation of (S)-mephenytoin labeled with tritium in the 4' position. Because this reaction is subject to an NIH shift, tritium was also introduced into the 3'- and 5'-positions of the tracer to enhance formation of a tritiated water product. Tritiated water was separated from the substrate using 96-well solid-phase extraction plates. The reaction is NADPH-dependent and sensitive to CYP2C19 inhibitors. IC(50) values for 15 diverse drugs differed less than 2.5-fold from those determined by quantification of the unlabeled 4'-hydroxy-(S)-mephenytoin product, using HPLC coupled to mass spectrometric detection. All of the steps of the new assay, namely incubation, product separation, and radioactivity counting, are performed in a 96-well format and can be automated. This assay represents a non-HPLC, high-throughput version of the classic (S)-mephenytoin 4'-hydroxylation assay, which is the most widely used method to assess the potential for CYP2C19 inhibition of new chemical entities.

  18. Site characterization for calibration of radiometric sensors using vicarious method

    NASA Astrophysics Data System (ADS)

    Parihar, Shailesh; Rathore, L. S.; Mohapatra, M.; Sharma, A. K.; Mitra, A. K.; Bhatla, R.; Singh, R. S.; Desai, Yogdeep; Srivastava, Shailendra S.

    2016-05-01

    Radiometric performances of earth observation satellite/sensors vary from ground pre-launch calibration campaign to post launch period extended to lifetime of the satellite due to launching vibrations. Therefore calibration is carried out worldwide through various methods throughout satellite lifetime. In India Indian Space Research Organization (ISRO) calibrates the sensor of Resourcesat-2 satellite by vicarious method. One of these vicarious calibration methods is the reflectance-based approach that is applied in this study for radiometric calibration of sensors on-board Resouresat-2 satellite. The results of ground-based measurement of atmospheric conditions and surface reflectance are made at Bap, Rajasthan Calibration/Validation (Cal/Val) site. Cal/Val observations at site were carried out with hyper-spectral Spectroradiometer covering spectral range of 350nm- 2500nm for radiometric characterization of the site. The Sunphotometer/Ozonometer for measuring the atmospheric parameters has also been used. The calibrated radiance is converted to absolute at-sensor spectral reflectance and Top-Of-Atmosphere (TOA) radiance. TOA radiance was computed using radiative transfer model `Second simulation of the satellite signal in the solar spectrum' (6S), which can accurately simulate the problems introduced by the presence of the atmosphere along the path from Sun to target (surface) to Sensor. The methodology for band averaged reflectance retrieval and spectral reflectance fitting process are described. Then the spectral reflectance and atmospheric parameters are put into 6S code to predict TOA radiance which compare with Resourcesat-2 radiance. Spectral signature and its reflectance ratio indicate the uniformity of the site. Thus the study proves that the selected site is suitable for vicarious calibration of sensor of Resourcesat-2. Further the study demonstrates the procedure for similar exercise for site selection for Cal/Val analysis of other satellite over India

  19. Radiometric calibration of digital cameras using Gaussian processes

    NASA Astrophysics Data System (ADS)

    Schall, Martin; Grunwald, Michael; Umlauf, Georg; Franz, Matthias O.

    2015-05-01

    Digital cameras are subject to physical, electronic and optic effects that result in errors and noise in the image. These effects include for example a temperature dependent dark current, read noise, optical vignetting or different sensitivities of individual pixels. The task of a radiometric calibration is to reduce these errors in the image and thus improve the quality of the overall application. In this work we present an algorithm for radiometric calibration based on Gaussian processes. Gaussian processes are a regression method widely used in machine learning that is particularly useful in our context. Then Gaussian process regression is used to learn a temperature and exposure time dependent mapping from observed gray-scale values to true light intensities for each pixel. Regression models based on the characteristics of single pixels suffer from excessively high runtime and thus are unsuitable for many practical applications. In contrast, a single regression model for an entire image with high spatial resolution leads to a low quality radiometric calibration, which also limits its practical use. The proposed algorithm is predicated on a partitioning of the pixels such that each pixel partition can be represented by one single regression model without quality loss. Partitioning is done by extracting features from the characteristic of each pixel and using them for lexicographic sorting. Splitting the sorted data into partitions with equal size yields the final partitions, each of which is represented by the partition centers. An individual Gaussian process regression and model selection is done for each partition. Calibration is performed by interpolating the gray-scale value of each pixel with the regression model of the respective partition. The experimental comparison of the proposed approach to classical flat field calibration shows a consistently higher reconstruction quality for the same overall number of calibration frames.

  20. Radiometric calibration of the Landsat MSS sensor series

    USGS Publications Warehouse

    Helder, Dennis L.; Karki, Sadhana; Bhatt, Rajendra; Micijevik, Esad; Aaron, David; Jasinski, Benjamin

    2012-01-01

    Multispectral remote sensing of the Earth using Landsat sensors was ushered on July 23, 1972, with the launch of Landsat-1. Following that success, four more Landsat satellites were launched, and each of these carried the Multispectral Scanner System (MSS). These five sensors provided the only consistent multispectral space-based imagery of the Earth's surface from 1972 to 1982. This work focuses on developing both a consistent and absolute radiometric calibration of this sensor system. Cross-calibration of the MSS was performed through the use of pseudoinvariant calibration sites (PICSs). Since these sites have been shown to be stable for long periods of time, changes in MSS observations of these sites were attributed to changes in the sensors themselves. In addition, simultaneous data collections were available for some MSS sensor pairs, and these were also used for cross-calibration. Results indicated substantial differences existed between instruments, up to 16%, and these were reduced to 5% or less across all MSS sensors and bands. Lastly, this paper takes the calibration through the final step and places the MSS sensors on an absolute radiometric scale. The methodology used to achieve this was based on simultaneous data collections by the Landsat-5 MSS and Thematic Mapper (TM) instruments. Through analysis of image data from a PICS location and through compensating for the spectral differences between the two instruments, the Landsat-5 MSS sensor was placed on an absolute radiometric scale based on the Landsat-5 TM sensor. Uncertainties associated with this calibration are considered to be less than 5%.

  1. BOREAS TE-18, 30-m, Radiometrically Rectified Landsat TM Imagery

    NASA Technical Reports Server (NTRS)

    Hall, Forrest G. (Editor); Knapp, David

    2000-01-01

    The BOREAS TE-18 team used a radiometric rectification process to produce standardized DN values for a series of Landsat TM images of the BOREAS SSA and NSA in order to compare images that were collected under different atmospheric conditions. The images for each study area were referenced to an image that had very clear atmospheric qualities. The reference image for the SSA was collected on 02-Sep-1994, while the reference image for the NSA was collected on 21-Jun-1995. the 23 rectified images cover the period of 07-Jul-1985 to 18 Sep-1994 in the SSA and from 22-Jun-1984 to 09-Jun-1994 in the NSA. Each of the reference scenes had coincident atmospheric optical thickness measurements made by RSS-11. The radiometric rectification process is described in more detail by Hall et al. (199 1). The original Landsat TM data were received from CCRS for use in the BOREAS project. The data are stored in binary image-format files. Due to the nature of the radiometric rectification process and copyright issues, these full-resolution images may not be publicly distributed. However, a spatially degraded 60-m resolution version of the images is available on the BOREAS CD-ROM series. See Sections 15 and 16 for information about how to possibly acquire the full resolution data. Information about the full-resolution images is provided in an inventory listing on the CD-ROMs. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Activity Archive Center (DAAC).

  2. A new radiometric unit of measure to characterize SWIR illumination

    NASA Astrophysics Data System (ADS)

    Richards, A.; Hübner, M.

    2017-05-01

    We propose a new radiometric unit of measure we call the `swux' to unambiguously characterize scene illumination in the SWIR spectral band between 0.8μm-1.8μm, where most of the ever-increasing numbers of deployed SWIR cameras (based on standard InGaAs focal plane arrays) are sensitive. Both military and surveillance applications in the SWIR currently suffer from a lack of a standardized SWIR radiometric unit of measure that can be used to definitively compare or predict SWIR camera performance with respect to SNR and range metrics. We propose a unit comparable to the photometric illuminance lux unit; see Ref. [1]. The lack of a SWIR radiometric unit becomes even more critical if one uses lux levels to describe SWIR sensor performance at twilight or even low light condition, since in clear, no-moon conditions in rural areas, the naturally-occurring SWIR radiation from nightglow produces a much higher irradiance than visible starlight. Thus, even well-intentioned efforts to characterize a test site's ambient illumination levels in the SWIR band may fail based on photometric instruments that only measure visible light. A study of this by one of the authors in Ref. [2] showed that the correspondence between lux values and total SWIR irradiance in typical illumination conditions can vary by more than two orders of magnitude, depending on the spectrum of the ambient background. In analogy to the photometric lux definition, we propose the SWIR irradiance equivalent `swux' level, derived by integration over the scene SWIR spectral irradiance weighted by a spectral sensitivity function S(λ), a SWIR analog of the V(λ) photopic response function.

  3. Office automation.

    PubMed

    Arenson, R L

    1986-03-01

    By now, the term "office automation" should have more meaning for those readers who are not intimately familiar with the subject. Not all of the preceding material pertains to every department or practice, but certainly, word processing and simple telephone management are key items. The size and complexity of the organization will dictate the usefulness of electronic mail and calendar management, and the individual radiologist's personal needs and habits will determine the usefulness of the home computer. Perhaps the most important ingredient for success in the office automation arena relates to the ability to integrate information from various systems in a simple and flexible manner. Unfortunately, this is perhaps the one area that most office automation systems have ignored or handled poorly. In the personal computer world, there has been much emphasis recently on integration of packages such as spreadsheet, database management, word processing, graphics, time management, and communications. This same philosophy of integration has been applied to a few office automation systems, but these are generally vendor-specific and do not allow for a mixture of foreign subsystems. During the next few years, it is likely that a few vendors will emerge as dominant in this integrated office automation field and will stress simplicity and flexibility as major components.

  4. Radiometric correction and equalization of satellite digital data

    NASA Technical Reports Server (NTRS)

    Algazi, V. R.; Ford, G. E.; Kazakoff, J. A.

    1979-01-01

    Satellite digital data from Landsat and NOAA satellites is often marred by striping or streaking errors due to variations in the response of the radiometric sensors. In this paper, we discuss the equalization of the digital data as a preprocessing step, prior to image enhancement or automatic classification. The methods described make use of statistics of the data itself to generate nonlinear or linear memory-less equalization algorithms. These algorithms, by contrast to multidimensional filtering, do not result in a loss of spatial resolution. Examples of applications to Landsat and NOAA-3 thermal infrared data are given and illustrated.

  5. Earth Observing-1 Advanced Land Imager: Radiometric Response Calibration

    NASA Technical Reports Server (NTRS)

    Mendenhall, J. A.; Lencioni, D. E.; Evans, J. B.

    2000-01-01

    The Advanced Land Imager (ALI) is one of three instruments to be flown on the first Earth Observing mission (EO-1) under NASA's New Millennium Program (NMP). ALI contains a number of innovative features, including a wide field of view optical design, compact multispectral focal plane arrays, non-cryogenic HgCdTe detectors for the short wave infrared bands, and silicon carbide optics. This document outlines the techniques adopted during ground calibration of the radiometric response of the Advanced Land Imager. Results from system level measurements of the instrument response, signal-to-noise ratio, saturation radiance, and dynamic range for all detectors of every spectral band are also presented.

  6. Evaluation of S190A radiometric exposure test data

    NASA Technical Reports Server (NTRS)

    Lockwood, H. E.; Goodding, R. A.

    1974-01-01

    The S190A preflight radiometric exposure test data generated as part of preflight and system test of KM-002 Sequence 29 on flight camera S/N 002 was analyzed. The analysis was to determine camera system transmission using available data which included: (1) films exposed to a calibrated light source subject; (2) filter transmission data; (3) calibrated light source data; (4) density vs. log10 exposure curves for the films; and (5) spectral sensitometric data for the films. The procedure used is outlined, and includes the data and a transmission matrix as a function of field position for nine measured points on each station-film-filter-aperture-shutter speed combination.

  7. Spectrally and Radiometrically Stable, Wideband, Onboard Calibration Source

    NASA Technical Reports Server (NTRS)

    Coles, James B.; Richardson, Brandon S.; Eastwood, Michael L.; Sarture, Charles M.; Quetin, Gregory R.; Porter, Michael D.; Green, Robert O.; Nolte, Scott H.; Hernandez, Marco A.; Knoll, Linley A.

    2013-01-01

    The Onboard Calibration (OBC) source incorporates a medical/scientific-grade halogen source with a precisely designed fiber coupling system, and a fiber-based intensity-monitoring feedback loop that results in radiometric and spectral stabilities to within less than 0.3 percent over a 15-hour period. The airborne imaging spectrometer systems developed at the Jet Propulsion Laboratory incorporate OBC sources to provide auxiliary in-use system calibration data. The use of the OBC source will provide a significant increase in the quantitative accuracy, reliability, and resulting utility of the spectral data collected from current and future imaging spectrometer instruments.

  8. Radiometric calibration of Landsat Thematic Mapper multispectral images

    USGS Publications Warehouse

    Chavez, P.S.

    1989-01-01

    A main problem encountered in radiometric calibration of satellite image data is correcting for atmospheric effects. Without this correction, an image digital number (DN) cannot be converted to a surface reflectance value. In this paper the accuracy of a calibration procedure, which includes a correction for atmospheric scattering, is tested. Two simple methods, a stand-alone and an in situ sky radiance measurement technique, were used to derive the HAZE DN values for each of the six reflectance Thematic Mapper (TM) bands. The DNs of two Landsat TM images of Phoenix, Arizona were converted to surface reflectances. -from Author

  9. MARS-3 matrix radiometric system for RATAN-600

    NASA Astrophysics Data System (ADS)

    Berlin, A. B.; Parijskij, Yu. N.; Nizhelskij, N. A.; Mingaliev, M. G.; Tsybulev, P. G.; Kratov, D. V.; Udovitskiy, R. Yu.; Smirnov, V. V.; Pylypenko, O. M.

    2012-07-01

    The MARS-3 third-generation matrix radiometric system has been developed, manufactured, and is currently being used in observations within the framework of the "Cosmological Gene" program. The system is based on new hardware components and consists of 16 independent radiometers (32 horns with a step of 20 mm). Each pair of horns is connected to the input of an amplifier unit via a square-loop modulator. The parameters of each radiometer are: central frequency, 30.0 GHz; bandwidth, 5GHz; average noise temperature of the system, 250 K; and a sensitivity of about 5 mK for τ = RC = 1 s.

  10. Virtual and remote experiments for radiometric and photometric measurements

    NASA Astrophysics Data System (ADS)

    Thoms, L.-J.; Girwidz, R.

    2017-09-01

    The analysis of spectra is fundamental to our modern understanding of wave optics and colour perception. Since spectrometers are expensive, and accurate calibration is necessary to achieve high quality spectra, we developed a remote lab on optical spectrometry. With this tool, students can carry out real experiments over the Internet. In this article the pros and cons of remote labs, the physical background of optical spectrometry, and the development and use of a radiometric remote lab for higher education are discussed. The remote lab is freely accessible to everyone at http://virtualremotelab.net.

  11. Radiometric method for the rapid detection of Leptospira organisms

    SciTech Connect

    Manca, N.; Verardi, R.; Colombrita, D.; Ravizzola, G.; Savoldi, E.; Turano, A.

    1986-02-01

    A rapid and sensitive radiometric method for detection of Leptospira interrogans serovar pomona and Leptospira interrogans serovar copenhageni is described. Stuart's medium and Middlebrook TB (12A) medium supplemented with bovine serum albumin, catalase, and casein hydrolysate and labeled with /sup 14/C-fatty acids were used. The radioactivity was measured in a BACTEC 460. With this system, Leptospira organisms were detected in human blood in 2 to 5 days, a notably shorter time period than that required for the majority of detection techniques.

  12. Cropland measurement using Thematic Mapper data and radiometric model

    NASA Technical Reports Server (NTRS)

    Lyon, John G.; Khuwaiter, I. H. S.

    1989-01-01

    To halt erosion and desertification, it is necessary to quantify resources that are affected. Necessary information includes inventory of croplands and desert areas as they change over time. Several studies indicate the value of remote sensor data as input to inventories. In this study, the radiometric modeling of spectral characteristics of soil and vegetation provides the theoretical basis for the remote sensing approach. Use of Landsat Thematic Mapper images allows measurement of croplands in Saudi Arabia, demonstrating the capability of the approach. The inventory techniques and remote sensing approach presented are potentially useful in developing countries.

  13. Cropland measurement using Thematic Mapper data and radiometric model

    NASA Technical Reports Server (NTRS)

    Lyon, John G.; Khuwaiter, I. H. S.

    1989-01-01

    To halt erosion and desertification, it is necessary to quantify resources that are affected. Necessary information includes inventory of croplands and desert areas as they change over time. Several studies indicate the value of remote sensor data as input to inventories. In this study, the radiometric modeling of spectral characteristics of soil and vegetation provides the theoretical basis for the remote sensing approach. Use of Landsat Thematic Mapper images allows measurement of croplands in Saudi Arabia, demonstrating the capability of the approach. The inventory techniques and remote sensing approach presented are potentially useful in developing countries.

  14. Radiometric calibration to consider in quantitative clinical fluorescence imaging measurements

    NASA Astrophysics Data System (ADS)

    Litorja, M.; Urbas, A.; Zong, Y.

    2015-03-01

    The fluorescent light detected by a clinical imager is assumed to be proportional only to the amount of fluorescent substance present in the sample and the level of excitation. Unfortunately, there are many factors that can add or subtract to the light signal directly attributable to the desired fluorescence emission, especially with fluorescence from inside the body imaged remotely. The quantification of fluorescence emission is feasible by calibrating the imager using international system of units (SI)-traceable physical and material calibration artifacts such that the detector's digital numbers (DN) can be converted to radiometric units. Here we discuss three calibration methods for quantitative clinical fluorescence imaging systems.

  15. Habitat automation

    NASA Technical Reports Server (NTRS)

    Swab, Rodney E.

    1992-01-01

    A habitat, on either the surface of the Moon or Mars, will be designed and built with the proven technologies of that day. These technologies will be mature and readily available to the habitat designer. We believe an acceleration of the normal pace of automation would allow a habitat to be safer and more easily maintained than would be the case otherwise. This document examines the operation of a habitat and describes elements of that operation which may benefit from an increased use of automation. Research topics within the automation realm are then defined and discussed with respect to the role they can have in the design of the habitat. Problems associated with the integration of advanced technologies into real-world projects at NASA are also addressed.

  16. Making SAR Data Accessible - ASF's ALOS PALSAR Radiometric Terrain Correction Project

    NASA Astrophysics Data System (ADS)

    Meyer, F. J.; Arko, S. A.; Gens, R.

    2015-12-01

    While SAR data have proven valuable for a wide range of geophysical research questions, so far, largely only the SAR-educated science communities have been able to fully exploit the information content of internationally available SAR archives. The main issues that have been preventing a more widespread utilization of SAR are related to (1) the diversity and complexity of SAR data formats, (2) the complexity of the processing flows needed to extract geophysical information from SAR, (3) the lack of standardization and automation of these processing flows, and (4) the often ignored geocoding procedures, leaving the data in image coordinate space. In order to improve upon this situation, ASF's radiometric terrain-correction (RTC) project is generating uniformly formatted and easily accessible value-added products from the ASF Distributed Active Archive Center's (DAAC) five-year archive of JAXA's ALOS PALSAR sensor. Specifically, the project applies geometric and radiometric corrections to SAR data to allow for an easy and direct combination of obliquely acquired SAR data with remote sensing imagery acquired in nadir observation geometries. Finally, the value-added data is provided to the user in the broadly accepted Geotiff format, in order to support the easy integration of SAR data into GIS environments. The goal of ASF's RTC project is to make SAR data more accessible and more attractive to the broader SAR applications community, especially to those users that currently have limited SAR expertise. Production of RTC products commenced October 2014 and will conclude late in 2015. As of July 2015, processing of 71% of ASF's ALOS PALSAR archive was completed. Adding to the utility of this dataset are recent changes to the data access policy that allow the full-resolution RTC products to be provided to the public, without restriction. In this paper we will introduce the processing flow that was developed for the RTC project and summarize the calibration and validation

  17. Principal Component Noise Filtering for NAST-I Radiometric Calibration

    NASA Technical Reports Server (NTRS)

    Tian, Jialin; Smith, William L., Sr.

    2011-01-01

    The National Polar-orbiting Operational Environmental Satellite System (NPOESS) Airborne Sounder Testbed- Interferometer (NAST-I) instrument is a high-resolution scanning interferometer that measures emitted thermal radiation between 3.3 and 18 microns. The NAST-I radiometric calibration is achieved using internal blackbody calibration references at ambient and hot temperatures. In this paper, we introduce a refined calibration technique that utilizes a principal component (PC) noise filter to compensate for instrument distortions and artifacts, therefore, further improve the absolute radiometric calibration accuracy. To test the procedure and estimate the PC filter noise performance, we form dependent and independent test samples using odd and even sets of blackbody spectra. To determine the optimal number of eigenvectors, the PC filter algorithm is applied to both dependent and independent blackbody spectra with a varying number of eigenvectors. The optimal number of PCs is selected so that the total root-mean-square (RMS) error is minimized. To estimate the filter noise performance, we examine four different scenarios: apply PC filtering to both dependent and independent datasets, apply PC filtering to dependent calibration data only, apply PC filtering to independent data only, and no PC filters. The independent blackbody radiances are predicted for each case and comparisons are made. The results show significant reduction in noise in the final calibrated radiances with the implementation of the PC filtering algorithm.

  18. On the observability of Mars entry navigation using radiometric measurements

    NASA Astrophysics Data System (ADS)

    Yu, Zhengshi; Cui, Pingyuan; Zhu, Shengying

    2014-10-01

    A thorough observability analysis of the Mars entry navigation using radiometric measurements from ground based beacons is performed. This analysis involves the evaluation of the Fisher information matrix which is derived from the maximum likelihood estimation. A series of navigation cases with multiple beacons are investigated, and both range and range-rate measurements are considered. The determinant of Fisher information matrix is used to quantify the observability of navigation system, while the trace of Fisher information matrix is used to determine the lower-bound of estimation errors. For one and two beacon cases, the navigation system is unobservable. However, the eigenvectors of Fisher information matrix give the observable and unobservable component. When three or more beacon measurements are employed, the states of entry vehicle become observable. Some valuable analytic conclusions on the relationship between the geometric configuration of beacons and observability are obtained consequently. Finally, simulation results from two navigation examples indicate that our effort is useful for understanding and assessing the observability of the Mars entry navigation using radiometric measurements.

  19. Radiometric calibration of Landsat Thematic Mapper Thermal Band

    NASA Technical Reports Server (NTRS)

    Wukelic, G. E.; Gibbons, D. E.; Martucci, L. M.; Foote, H. P.

    1989-01-01

    Radiometric calibration of satellite-acquired data is essential for quantitative scientific studies, as well as for a variety of image-processing applications. This paper describes a multiyear, on-orbit radiometric calibration of the Landsat Thematic Mapper (TM) Band 6 conducted at DOE's Pacific Northwest Laboratory. Numerous Landsat TM scenes acquired and analyzed included day and night coverages at several geographical locations over several seasons. Concurrent with Landsat overpasses, thermal field and local meteorological (surface and radiosonde) measurements were collected. At-satellite (uncorrected) radiances and temperatures for water and nonwater land cover were compared to ground truth (GT) measurements after making adjustments for atmospheric (using LOWTRAN), mixed-pixel, and emissivity effects. Results indicate that, for both water and nonwater features, TM Band 6 average corrected temperature determinations using local radiosonde data to adjust for atmospheric effects, and using appropriate emissivities, are within 1.0 C of GT temperature values. Temperatures of water pixels derived from uncorrected TM Band 6 data varied roughly between 1 and 3 C of ground truth values for water temperatures ranging between 4 and 24 C. Moreover, corrections using nonlocal and noncoincident radiosonde data resulted in errors as large as 12 C. Corrections using the U.S. Standard Atmosphere gave temperature values within 1 to 2 C of GT. The average uncertainty for field instruments was + or - 0.2 C; average uncertainty for Landsat TM corrected temperature determinations was + or - 0.4 C.

  20. Reduction of Radiometric Miscalibration—Applications to Pushbroom Sensors

    PubMed Central

    Rogaß, Christian; Spengler, Daniel; Bochow, Mathias; Segl, Karl; Lausch, Angela; Doktor, Daniel; Roessner, Sigrid; Behling, Robert; Wetzel, Hans-Ulrich; Kaufmann, Hermann

    2011-01-01

    The analysis of hyperspectral images is an important task in Remote Sensing. Foregoing radiometric calibration results in the assignment of incident electromagnetic radiation to digital numbers and reduces the striping caused by slightly different responses of the pixel detectors. However, due to uncertainties in the calibration some striping remains. This publication presents a new reduction framework that efficiently reduces linear and nonlinear miscalibrations by an image-driven, radiometric recalibration and rescaling. The proposed framework—Reduction Of Miscalibration Effects (ROME)—considering spectral and spatial probability distributions, is constrained by specific minimisation and maximisation principles and incorporates image processing techniques such as Minkowski metrics and convolution. To objectively evaluate the performance of the new approach, the technique was applied to a variety of commonly used image examples and to one simulated and miscalibrated EnMAP (Environmental Mapping and Analysis Program) scene. Other examples consist of miscalibrated AISA/Eagle VNIR (Visible and Near Infrared) and Hawk SWIR (Short Wave Infrared) scenes of rural areas of the region Fichtwald in Germany and Hyperion scenes of the Jalal-Abad district in Southern Kyrgyzstan. Recovery rates of approximately 97% for linear and approximately 94% for nonlinear miscalibrated data were achieved, clearly demonstrating the benefits of the new approach and its potential for broad applicability to miscalibrated pushbroom sensor data. PMID:22163960

  1. Radiometric measurement of metabolic activity of Mycobacterium lepraemurium.

    PubMed

    Camargo, E E; Larson, S M; Tepper, B S; Wagner, H N

    1974-09-01

    A sensitive and nondestructive radiometric method has been applied to the detection of metabolism of Mycobacterium lepraemurium, as a model for the study of the metabolism and substrate requirements of M. leprae. The method is based on the measurement of the (14)CO(2) produced through the bacterial conversion of [U-(14)C]acetate or [U-(14)C]glycerol by 7 x 10(9) bacteria suspended in 10 ml of either a simple buffer system (K-36) or a complex medium (NC-5). Metabolism of the bacilli was easily detected within 3 days after inoculation and was measured daily. NC-5 medium supported metabolism of M. lepraemurium for several weeks longer than the simple K-36 buffer. The radiometric technique shows promise as a rapid and efficient system for evaluating the metabolism of mycobacteria without introducing any changes in the physiologic state of the organisms, studying their metabolic pathways, determining conditions potentially favorable for multiplication of these organisms in vitro, and studying their susceptibility to inhibition by drugs.

  2. Investigation of radiometric properties of the LANDSAT-4 multispectral scanner

    NASA Technical Reports Server (NTRS)

    Malila, W. A. (Principal Investigator); Rice, D. P.

    1983-01-01

    The radiometric data quality of the LANDSAT 4 multispectral scanner (MSS) was examined using several LANDSAT 4 frames. It was found that LANDSAT 4 MSS produces high-quality data of the caliber experienced with previous LANDSATS. For example, the detector equalization procedure worked well, leaving a residual banding effect of about 0.3 digital counts RMS, close to the theoretical minimum value of quantization error. Nevertheless, artifacts of the data were found, two of which were not experienced in previous MSS data. A low-level coherent noise effect was observed in all bands, with a magnitude of about 0.5 digital counts and a frequency of approximately 28 KHz (representing a wavelength of about 3.6 pixels); a substantial increase in processing complexity would be required to reduce this artifact in the data. Also, a substantial scan-length variation (of up to six pixels) was noted in MSS data when the TM sensor was operating; the LANDSAT 4 correction algorithms being applied routinely by the EROS Data Center to produce a p-type data should remove most of this variation. Between-satellite calibrations were examined in paired LANDSAT 3 and LANDSAT 4 MSS data sets, which were closely matched in acquisition time and place. Radiometric comparisons showed that all bands were highly linear in digital counts, and a well-determined linear transformation between the MSS's was established.

  3. Radiometric and conventional drug susceptibility testing of Mycobacterium tuberculosis.

    PubMed

    Hoel, T; Eng, J

    1991-11-01

    One hundred and four clinical isolates of M. tuberculosis were susceptibility tested by the radiometric method (RAD) using the BACTEC system in parallel with a conventional modified proportion method (CON). In the latter, the strains were tested against four concentrations of drugs in Lowenstein-Jensen medium (isoniazid (INH), streptomycin (SM) and ethambutol (EMB)) OR 7H10 agar medium (rifampicin (RIF)) and reported as "sensitive", "intermediate" or "resistant" from the minimum inhibitory concentrations observed. The radiometric results were classified in the same three groups in accordance with the BACTEC methodology. The overall agreement between the results obtained by the two methods was 97.4% (INH 95.2%, EMB 96.2%, SM 98.1% and RIF 100%). In addition, the agreement between RAD and each of the drug concentration steps employed in CON was examined and the results discussed in relation to the established critical concentrations of the drugs. The BACTEC technique was found to be a rapid and convenient method for routine use.

  4. Radiometric infrared focal plane array imaging system for thermographic applications

    NASA Technical Reports Server (NTRS)

    Esposito, B. J.; Mccafferty, N.; Brown, R.; Tower, J. R.; Kosonocky, W. F.

    1992-01-01

    This document describes research performed under the Radiometric Infrared Focal Plane Array Imaging System for Thermographic Applications contract. This research investigated the feasibility of using platinum silicide (PtSi) Schottky-barrier infrared focal plane arrays (IR FPAs) for NASA Langley's specific radiometric thermal imaging requirements. The initial goal of this design was to develop a high spatial resolution radiometer with an NETD of 1 percent of the temperature reading over the range of 0 to 250 C. The proposed camera design developed during this study and described in this report provides: (1) high spatial resolution (full-TV resolution); (2) high thermal dynamic range (0 to 250 C); (3) the ability to image rapid, large thermal transients utilizing electronic exposure control (commandable dynamic range of 2,500,000:1 with exposure control latency of 33 ms); (4) high uniformity (0.5 percent nonuniformity after correction); and (5) high thermal resolution (0.1 C at 25 C background and 0.5 C at 250 C background).

  5. Calculated sensitivities of several optical radiometric indices for vegetation canopies

    NASA Technical Reports Server (NTRS)

    Shultis, J. K.

    1991-01-01

    The present study employs a radiative transfer model for a vegetation canopy to compute several quantities used in remote sensing applications and to determine the sensitivity of these radiometric quantities to several of the important problem parameters. Attention is given to the ratio of near IR to visible reflected intensities in the nadir direction, the ratio of the fraction of incident energy reflected in the near IR to that in the visible, the normalized difference between the near IR and visible nadir-reflected intensities, and the visible intensity transmitted in a given downward direction. A realistic radiative transfer model is proposed for calculating these radiometric quantities. With these models, the sensitivity of the reflected and transmitted quantities to various canopy and illumination conditions are then determined. The sensitivity of the calculated quantities are presented as a function of the leaf area index of the canopy, and, for the reflected quantities, also as a function of the fraction of visible light absorbed in the canopy.

  6. a Comparison of LIDAR Reflectance and Radiometrically Calibrated Hyperspectral Imagery

    NASA Astrophysics Data System (ADS)

    Roncat, A.; Briese, C.; Pfeifer, N.

    2016-06-01

    In order to retrieve results comparable under different flight parameters and among different flight campaigns, passive remote sensing data such as hyperspectral imagery need to undergo a radiometric calibration. While this calibration, aiming at the derivation of physically meaningful surface attributes such as a reflectance value, is quite cumbersome for passively sensed data and relies on a number of external parameters, the situation is by far less complicated for active remote sensing techniques such as lidar. This fact motivates the investigation of the suitability of full-waveform lidar as a "single-wavelength reflectometer" to support radiometric calibration of hyperspectral imagery. In this paper, this suitability was investigated by means of an airborne hyperspectral imagery campaign and an airborne lidar campaign recorded over the same area. Criteria are given to assess diffuse reflectance behaviour; the distribution of reflectance derived by the two techniques were found comparable in four test areas where these criteria were met. This is a promising result especially in the context of current developments of multi-spectral lidar systems.

  7. Reduction of radiometric miscalibration--applications to pushbroom sensors.

    PubMed

    Rogass, Christian; Spengler, Daniel; Bochow, Mathias; Segl, Karl; Lausch, Angela; Doktor, Daniel; Roessner, Sigrid; Behling, Robert; Wetzel, Hans-Ulrich; Kaufmann, Hermann

    2011-01-01

    The analysis of hyperspectral images is an important task in Remote Sensing. Foregoing radiometric calibration results in the assignment of incident electromagnetic radiation to digital numbers and reduces the striping caused by slightly different responses of the pixel detectors. However, due to uncertainties in the calibration some striping remains. This publication presents a new reduction framework that efficiently reduces linear and nonlinear miscalibrations by an image-driven, radiometric recalibration and rescaling. The proposed framework-Reduction Of Miscalibration Effects (ROME)-considering spectral and spatial probability distributions, is constrained by specific minimisation and maximisation principles and incorporates image processing techniques such as Minkowski metrics and convolution. To objectively evaluate the performance of the new approach, the technique was applied to a variety of commonly used image examples and to one simulated and miscalibrated EnMAP (Environmental Mapping and Analysis Program) scene. Other examples consist of miscalibrated AISA/Eagle VNIR (Visible and Near Infrared) and Hawk SWIR (Short Wave Infrared) scenes of rural areas of the region Fichtwald in Germany and Hyperion scenes of the Jalal-Abad district in Southern Kyrgyzstan. Recovery rates of approximately 97% for linear and approximately 94% for nonlinear miscalibrated data were achieved, clearly demonstrating the benefits of the new approach and its potential for broad applicability to miscalibrated pushbroom sensor data.

  8. Radiometric calibration of Landsat Thematic Mapper Thermal Band

    NASA Technical Reports Server (NTRS)

    Wukelic, G. E.; Gibbons, D. E.; Martucci, L. M.; Foote, H. P.

    1989-01-01

    Radiometric calibration of satellite-acquired data is essential for quantitative scientific studies, as well as for a variety of image-processing applications. This paper describes a multiyear, on-orbit radiometric calibration of the Landsat Thematic Mapper (TM) Band 6 conducted at DOE's Pacific Northwest Laboratory. Numerous Landsat TM scenes acquired and analyzed included day and night coverages at several geographical locations over several seasons. Concurrent with Landsat overpasses, thermal field and local meteorological (surface and radiosonde) measurements were collected. At-satellite (uncorrected) radiances and temperatures for water and nonwater land cover were compared to ground truth (GT) measurements after making adjustments for atmospheric (using LOWTRAN), mixed-pixel, and emissivity effects. Results indicate that, for both water and nonwater features, TM Band 6 average corrected temperature determinations using local radiosonde data to adjust for atmospheric effects, and using appropriate emissivities, are within 1.0 C of GT temperature values. Temperatures of water pixels derived from uncorrected TM Band 6 data varied roughly between 1 and 3 C of ground truth values for water temperatures ranging between 4 and 24 C. Moreover, corrections using nonlocal and noncoincident radiosonde data resulted in errors as large as 12 C. Corrections using the U.S. Standard Atmosphere gave temperature values within 1 to 2 C of GT. The average uncertainty for field instruments was + or - 0.2 C; average uncertainty for Landsat TM corrected temperature determinations was + or - 0.4 C.

  9. Radiometric tests on wet and dry antenna reflector surface panels

    NASA Technical Reports Server (NTRS)

    Otoshi, T. Y.; Franco, M. M.

    1990-01-01

    The results of X-band noise temperature tests on two types of antenna surface panels are presented. The first type tested was a solid antenna panel, while the second type was a perforated panel with 3/16-in.-diameter holes. Measurements were made at 8.45 GHz using an X-band radiometric system. Included in this article are measured noise temperature contributions from: (1) thermal diffusive white paint on solid and perforated panels, and (2) water sprayed on both painted and unpainted perforated panels. Experiments on perforated panels were restricted to the 3/16-in.-diameter hole panels formerly used on Deep Space Network 64-m antennas. Rigorous calibration equations, applicable to a variety of antenna panel and dichroic plate test configurations, are presented. It was demonstrated that an accurate, stable radiometric measurement system of the type used for the results of this research makes it possible to obtain information that would be much more difficult to obtain using other techniques.

  10. Branching Ratios for The Radiometric Calibration of EUNIS-2012

    NASA Technical Reports Server (NTRS)

    Daw, Adrian N.; Bhatia, A. K.; Rabin, Douglas M.

    2012-01-01

    The Extreme Ultraviolet Normal Incidence Spectrograph (EUNIS) sounding rocket instrument is a two-channel imaging spectrograph that observes the solar corona and transition region with high spectral resolution and a rapid cadence made possible by unprecedented sensitivity. The upcoming flight will incorporate a new wavelength channel covering the range 524-630 Angstroms, the previously-flown 300-370 Angstroms channel, and the first flight demonstration of cooled active pixel sensor (APS) arrays. The new 524-630 Angstrom channel incorporates a Toroidal Varied Line Space (TVLS) grating coated with B4C/Ir, providing broad spectral coverage and a wide temperature range of 0.025 to 10 MK. Absolute radiometric calibration of the two channels is being performed using a hollow cathode discharge lamp and NIST-calibrated AXUV-100G photodiode. Laboratory observations of He I 584 Angstroms and He II 304 Angstroms provide absolute radiometric calibrations of the two channels at those two respective wavelengths by using the AXUV photodiode as a transfer standard. The spectral responsivity is being determined by observing line pairs with a common upper state in the spectra of Ne I-III and Ar II-III. Calculations of A-values for the observed branching ratios are in progress.

  11. Automated Coastal Engineering System: Technical Reference

    DTIC Science & Technology

    1992-09-01

    Randomf3J ___ (3) 2.9(1) - - . (3) 2.3(1) 1.5-3.0(8) 1.9(1) 3.2 1.5 Rough angular 2 Random 2.0 4.0 1.6(1) 2.8 2.0 1.3 2.3 3.0 Rough angular >8...Random 2.2(1) 4.5(1) 2.1111 4 .2(1) 1.5-3.0(81 Rough angular 2 Spec:iaJ(4J 5.8 . 7.0 5.3(1) 6 .4 1.5-3.0(8) Parallelepiped(9J 2 Special 7.0- 20.0 8.5

  12. Advanced automation for space missions: Technical summary

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Several representative missions which would require extensive applications of machine intelligence were identified and analyzed. The technologies which must be developed to accomplish these types of missions are discussed. These technologies include man-machine communication, space manufacturing, teleoperators, and robot systems.

  13. Automated Technical Library System Users Manual.

    DTIC Science & Technology

    1979-12-01

    reports f. proposals g. planning documentation h. plans and diagrams " The Navy Energy R&D Office document collection * Intelligence documentation...Aerodynamics * Energy conservation 0 Fuels * Pollution abatement 0 Marine propulsion plants * Ships auxiliary systems The Library thesaurus is a special kind of...TEMPERATURE 7 ITEMS SAVED AS SET 5 11 Symbol Meaning Explanation USE OR Select one or For example: more of the following terms 6/ ENERGY USAGE DO YOU

  14. Automating Finance

    ERIC Educational Resources Information Center

    Moore, John

    2007-01-01

    In past years, higher education's financial management side has been riddled with manual processes and aging mainframe applications. This article discusses schools which had taken advantage of an array of technologies that automate billing, payment processing, and refund processing in the case of overpayment. The investments are well worth it:…

  15. Technical Services Research, 1988-1991.

    ERIC Educational Resources Information Center

    Simpson, Charles W.

    1992-01-01

    Reviews research published between 1988 and 1991 in technical services in the areas of acquisitions, including automation, costs, and vendor analysis; authority control; automation; cataloging, including costs and time analysis, rules and theory, expert systems, online catalogs, and shared cataloging; classification; preservation; serials; subject…

  16. Evaluating Radiometric Measurements Using a Fixed 45 Degrees Responsivity and Zenith Angle Dependent Responsivities (Poster)

    SciTech Connect

    Dooraghi, M.; Habte, A.; Reda, I.; Sengupta, M.; Gotseff, P.; Andreas, A.; Anderberg, M.

    2014-03-01

    This poster seeks to demonstrate the importance and application of an existing but unused approach that ultimately reduces the uncertainty of radiometric measurements. Current radiometric data is based on a single responsivity value that introduces significant uncertainty to the data, however, through using responsivity as a function of solar zenith angle, the uncertainty could be decreased by 50%.

  17. Galileo SSI/Gaspra Radiometrically Calibrated Images V1.0

    NASA Astrophysics Data System (ADS)

    Domingue, D. L.

    2015-05-01

    This data set includes Galileo Orbiter SSI radiometrically calibrated images of the asteroid 951 Gaspra, created using ISIS software and assuming nadir pointing. This is an original delivery of radiometrically calibrated files, not an update to existing files. All images archived include the the asteroid within the image frame. Calibration was performed in 2013-2014.

  18. Galileo SSI/Ida Radiometrically Calibrated Images V1.0

    NASA Astrophysics Data System (ADS)

    Domingue, D. L.

    2016-05-01

    This data set includes Galileo Orbiter SSI radiometrically calibrated images of the asteroid 243 Ida, created using ISIS software and assuming nadir pointing. This is an original delivery of radiometrically calibrated files, not an update to existing files. All images archived include the asteroid within the image frame. Calibration was performed in 2013-2014.

  19. Application of radiometric surface temperature for surface energy balance estimation: John Monteith's contributions

    USDA-ARS?s Scientific Manuscript database

    Over 25 years ago, Huband and Monteith paper’s investigating the radiative surface temperature and the surface energy balance of a wheat canopy, highlighted the key issues in computing fluxes with radiometric surface temperature. These included the relationship between radiometric and aerodynamic s...

  20. The Landsat Data Continuity Mission Operational Land Imager (OLI) Radiometric Calibration

    NASA Technical Reports Server (NTRS)

    Markham, Brian L.; Dabney, Philip W.; Murphy-Morris, Jeanine E.; Knight, Edward J.; Kvaran, Geir; Barsi, Julia A.

    2010-01-01

    The Operational Land Imager (OLI) on the Landsat Data Continuity Mission (LDCM) has a comprehensive radiometric characterization and calibration program beginning with the instrument design, and extending through integration and test, on-orbit operations and science data processing. Key instrument design features for radiometric calibration include dual solar diffusers and multi-lamped on-board calibrators. The radiometric calibration transfer procedure from NIST standards has multiple checks on the radiometric scale throughout the process and uses a heliostat as part of the transfer to orbit of the radiometric calibration. On-orbit lunar imaging will be used to track the instruments stability and side slither maneuvers will be used in addition to the solar diffuser to flat field across the thousands of detectors per band. A Calibration Validation Team is continuously involved in the process from design to operations. This team uses an Image Assessment System (IAS), part of the ground system to characterize and calibrate the on-orbit data.

  1. ROSCAM: a 95-GHz radiometric one-second camera

    NASA Astrophysics Data System (ADS)

    Smith, Roger M.; Sundstrom, Bryce M.; Belcher, Byron W.; Ewen, Doc

    1998-08-01

    The ability to obtain millimeter wave images under a variety of environmental conditions, such as rain, snow, fog, smoke, dust, etc., has numerous DoD as well as commercial applications. The demonstrated ability to look through doors, walls and clothing has recently extended potential millimeter wave applications to contraband detection and surveillance within buildings. Though the phenomenology supports the generation of high quality millimeter wave images, present-day frame time capabilities limit the use of millimeter wave cameras. Several solutions to frame time reduction are currently being investigated within government and industry. Two popular approaches include: (1) Electronic scanning focal plane arrays (FPA); (2) Mechanical raster scanning of a single antenna beam. One significant difference between the two approaches noted above is the number of receiving channels required. This is important because camera cost is driven by the number of receiver channels used in a camera, as well as the added complexities associated with inter-channel gain stability. There are a number of applications that do not require a motion picture capability. Images obtained sequentially at a nominal rate of one per second would satisfy the needs of a wide range of applications. It is evident, however, that the motion picture quality of a starring FPA may ultimately reduce the market for one-second cameras. In the interim, the one-second camera fills an important need. The goal of the Radiometric One Second Camera (ROSCAM) investigation is to demonstrate a practical millimeter-wave imaging (MMWI) camera, with a frame time of approximately one second. The approach combines a high-speed mechanical raster scanning antenna system with a single-channel radiometric receiving system. For baseline comparison, it is assumed that the scene is comprised of 1,000 pixels, each sampled for one millisecond, to generate a single frame in one second. The ROSCAM is based on combining a state

  2. Final Technical Report

    SciTech Connect

    Juan Camilo Serrano

    2011-12-16

    New and novel material and process technologies applied in wind blade designs and production are critical to increasing the competitiveness of wind power generation against traditional sources of energy. In this project, through collaboration between PPG Industries and MAG Industrial Automation Systems, the potential of using automated manufacturing for the production of fiber glass composite wind blades was evaluated from both technical and economic points of view. Further, it was demonstrated that by modifying the standard blade raw material forms through the use of cost effective pre-impregnated rovings coupled with using an automated fiber placement machine to lay up the parts, it is possible to produce state of the art composite laminates with significantly improved mechanical performance and with higher processing rates than standard blade production technology allows for today, thereby lowering the cost of energy over turbine blades made using traditional processes and materials. In conformity with the scope of work of the submitted proposal, the project team completed each task and documented and reported its findings on the appropriate quarterly report submitted to the DOE project team. The activities and this report are divided into 5 subtasks: (1) Material Investigation - Reviews traditional materials and key specifications and testing methods; (2) Manufacturing and Automation - Identifies new candidate material forms and automated layup processes; (3) Process Development - Performs trials of candidate materials and processes; (4) Predictive Analysis - Assesses impact of new material forms and automated processes on a model blade design; and (5) Feasibility Assessment - Compares traditional manufacturing processes and materials to new candidate material forms and automated processes.

  3. Fully automated urban traffic system

    NASA Technical Reports Server (NTRS)

    Dobrotin, B. M.; Hansen, G. R.; Peng, T. K. C.; Rennels, D. A.

    1977-01-01

    The replacement of the driver with an automatic system which could perform the functions of guiding and routing a vehicle with a human's capability of responding to changing traffic demands was discussed. The problem was divided into four technological areas; guidance, routing, computing, and communications. It was determined that the latter three areas being developed independent of any need for fully automated urban traffic. A guidance system that would meet system requirements was not being developed but was technically feasible.

  4. Reducing Peak Power in Automated Weapon Laying

    DTIC Science & Technology

    2016-02-01

    UNCLASSIFIED UNCLASSIFIED AD-E403 AD-E403 737 Technical Report ARWSE-TR-15036 REDUCING PEAK POWER IN AUTOMATED WEAPON...PEAK POWER IN AUTOMATED WEAPON LAYING 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHORS Joshua Stapp and...amount of time while reducing the amount of peak power required and, therefore, minimizing the forces caused by acceleration. 15. SUBJECT TERMS

  5. New Sentinel-2 radiometric validation approaches (SEOM program)

    NASA Astrophysics Data System (ADS)

    Bruniquel, Véronique; Lamquin, Nicolas; Ferron, Stéphane; Govaerts, Yves; Woolliams, Emma; Dilo, Arta; Gascon, Ferran

    2016-04-01

    SEOM is an ESA program element whose one of the objectives aims at launching state-of-the-art studies for the scientific exploitation of operational missions. In the frame of this program, ESA awarded ACRI-ST and its partners Rayference and National Physical Laboratory (NPL) early 2016 for a R&D study on the development and intercomparison of algorithms for validating the Sentinel-2 radiometric L1 data products beyond the baseline algorithms used operationally in the frame of the S2 Mission Performance Centre. In this context, several algorithms have been proposed and are currently in development: The first one is based on the exploitation of Deep Convective Cloud (DCC) observations over ocean. This method allows an inter-band radiometry validation from the blue to the NIR (typically from B1 to B8a) from a reference band already validated for example with the well-known Rayleigh method. Due to their physical properties, DCCs appear from the remote sensing point of view to have bright and cold tops and they can be used as invariant targets to monitor the radiometric response degradation of reflective solar bands. The DCC approach is statistical i.e. the method shall be applied on a large number of measurements to derive reliable statistics and decrease the impact of the perturbing contributors. The second radiometric validation method is based on the exploitation of matchups combining both concomitant in-situ measurements and Sentinel-2 observations. The in-situ measurements which are used here correspond to measurements acquired in the frame of the RadCalNet networks. The validation is performed for the Sentinel-2 bands similar to the bands of the instruments equipping the validation site. The measurements from the Cimel CE 318 12-filters BRDF Sun Photometer installed recently in the Gobabeb site near the Namib desert are used for this method. A comprehensive verification of the calibration requires an analysis of MSI radiances over the full dynamic range

  6. Radiometric calibration and SNR calculation of a SWIR imaging telescope

    SciTech Connect

    Yilmaz, Ozgur; Turk, Fethi; Selimoglu, Ozgur

    2012-09-06

    Radiometric calibration of an imaging telescope is usually made using a uniform illumination sphere in a laboratory. In this study, we used the open-sky images taken during bright day conditions to calibrate our telescope. We found a dark signal offset value and a linear response coefficient value for each pixel by using three different algorithms. Then we applied these coefficients to the taken images, and considerably lowered the image non-uniformity. Calibration can be repeated during the operation of telescope with an object that has better uniformity than open-sky. Also SNR (Signal to Noise Ratio) of each pixel was calculated from the open-sky images using the temporal mean and standard deviations. It is found that SNR is greater than 80 for all pixels even at low light levels.

  7. Radiometric Ages of Martian Meteorites compared to Martian Surfaces Ages

    NASA Technical Reports Server (NTRS)

    Nyquist, L. E.; Shih, C.-Y.

    1999-01-01

    The surprisingly young Rb-Sr age of the Shergotty meteorite contributed to early suggestions that it might be of martian origin. their redox state and oxygen isotopic compositions linked the shergottites to the clino-pyroxenite nakhlites and the dunite Chassigny, causing them to be grouped as SNC meteorites. These characteristics, but especially the similarity of the elemental and isotopic compositions of gases trapped in shergottites to those of the martian atmosphere, have caused the martian origin of the SNC and related meteorites to be widely accepted. Although the young ages were one of the early hints of a martian origin for the SNC meteorites, their interpretation has remained somewhat ambiguous. We will review the radiometric ages of the martian meteorites and attempt to place them into the context of martian surface ages.

  8. Summary of flight technology workshop on radiometric calibration

    NASA Technical Reports Server (NTRS)

    Dodgen, J. A.

    1980-01-01

    The conclusions and recommendations from a three-day NASA sponsored workshop to assess deficiencies and shortcomings of previously flown electro-optical space sensors are summarized. Space technologists for NASA, NOAA, DOD, and industry also developed recommendations for improving instrumentation and calibration technology. The conclusions reached include the fact that the past knowledge of in-orbit radiometric accuracy has been poor relative to available calibration standards, whereas stringent accuracy requirements for planned NASA programs will require significant SOA improvements. The Shuttle contamination environment may also compromise future sensor accuracy. A number of panel recommendations to improve in-orbit accuracy of future sensors will be summarized, including one to establish a set of National Standards for Remote Sensors at NBS as a basis for long term accuracy.

  9. Determination of precipitation profiles from airborne passive microwave radiometric measurements

    NASA Technical Reports Server (NTRS)

    Kummerow, Christian; Hakkarinen, Ida M.; Pierce, Harold F.; Weinman, James A.

    1991-01-01

    This study presents the first quantitative retrievals of vertical profiles of precipitation derived from multispectral passive microwave radiometry. Measurements of microwave brightness temperature (Tb) obtained by a NASA high-altitude research aircraft are related to profiles of rainfall rate through a multichannel piecewise-linear statistical regression procedure. Statistics for Tb are obtained from a set of cloud radiative models representing a wide variety of convective, stratiform, and anvil structures. The retrieval scheme itself determines which cloud model best fits the observed meteorological conditions. Retrieved rainfall rate profiles are converted to equivalent radar reflectivity for comparison with observed reflectivities from a ground-based research radar. Results for two case studies, a stratiform rain situation and an intense convective thunderstorm, show that the radiometrically derived profiles capture the major features of the observed vertical structure of hydrometer density.

  10. Radiometric resolution for monitoring vegetation: How many bits are needed?

    NASA Technical Reports Server (NTRS)

    Tucker, C. J.

    1979-01-01

    The significance of the various number of radiometric quantizing levels required for satellite monitoring of vegetation resources was evaluated by using in situ collected spectral reflectance data, an atmospheric radiative transfer simulation model, and a satellite sensor simulation model. Reflectance data were converted to radiance data; passed through a model atmosphere to an altitude of 706 km; and subsequently quantized at 16, 32, 64, 128, 256, and 512 digital count levels for Thematic Mapper bands TM3(0.63 - 0.69 microns) and TM4(0.76 - 0.90 microns). The simulated digital count data were regressed against the in situ biological data to quantify the relationship between quantizing levels.

  11. Radiometric performance of the Viking Mars lander cameras

    NASA Technical Reports Server (NTRS)

    Huck, F. O.; Burcher, E. E.; Taylor, E. J.; Wall, S. D.

    1975-01-01

    The Viking lander cameras feature an array of 12 silicon photodiodes for electronic focus selection and multispectral imaging. Comparisons of absolute radiometric calibrations of the four cameras selected for the mission to Mars with performance predictions based on their design data revealed minor discrepancies. These discrepancies were caused primarily by the method used to calibrate the photosensor array and apparently also from light reflections internal to the array. The sensitivity and dynamic range of all camera channels are found to be sufficient for high quality pictures, providing that the commandable gains and offsets can be optimized for the scene radiance; otherwise, the quantization noise may be too high or the dynamic range too low for an adequate characterization of the scene.

  12. Active radiometric calorimeter for absolute calibration of radioactive sources

    SciTech Connect

    Stump, K.E.; DeWerd, L.A.; Rudman, D.A.; Schima, S.A.

    2005-03-01

    This report describes the design and initial noise floor measurements of a radiometric calorimeter designed to measure therapeutic medical radioactive sources. The instrument demonstrates a noise floor of approximately 2 nW. This low noise floor is achieved by using high temperature superconducting (HTS) transition edge sensor (TES) thermometers in a temperature-control feedback loop. This feedback loop will be used to provide absolute source calibrations based upon the electrical substitution method. Other unique features of the calorimeter are (a) its ability to change sources for calibration without disrupting the vacuum of the instrument, and (b) the ability to measure the emitted power of a source in addition to the total contained source power.

  13. Retrieval of effective cloud field parameters from radiometric data

    NASA Astrophysics Data System (ADS)

    Paulescu, Marius; Badescu, Viorel; Brabec, Marek

    2017-06-01

    Clouds play a key role in establishing the Earth's climate. Real cloud fields are very different and very complex in both morphological and microphysical senses. Consequently, the numerical description of the cloud field is a critical task for accurate climate modeling. This study explores the feasibility of retrieving the effective cloud field parameters (namely the cloud aspect ratio and cloud factor) from systematic radiometric measurements at high frequency (measurement is taken every 15 s). Two different procedures are proposed, evaluated, and discussed with respect to both physical and numerical restrictions. None of the procedures is classified as best; therefore, the specific advantages and weaknesses are discussed. It is shown that the relationship between the cloud shade and point cloudiness computed using the estimated cloud field parameters recovers the typical relationship derived from measurements.

  14. High dynamic range infrared thermography by pixelwise radiometric self calibration

    NASA Astrophysics Data System (ADS)

    Ochs, M.; Schulz, A.; Bauer, H.-J.

    2010-03-01

    A procedure is described where the response function of each pixel of an InSb detector is determined by radiometric self-calibration. With the present approach no knowledge of the spectral characteristics of the IR system is required to recover a quantity which is linear with the incident irradiance of the object. The inherent detector non-uniformity is corrected on the basis of self-calibrated scaled irradiance. Compared to the standard two-point non-uniformity correction procedure - performed with the detector signal - only two NUC-tables are required for arbitrary integration times. Images obtained at various exposures are fused to a single high dynamic range image. The procedure is validated with synthetic data and its performance is demonstrated by measurements performed with a high resolution InSb FPA.

  15. Revised radiometric calibration technique for LANDSAT-4 Thematic Mapper data

    NASA Technical Reports Server (NTRS)

    Murphy, J.; Butlin, T.; Duff, P.; Fitzgerald, A.

    1984-01-01

    Depending on detector number, there are random fluctuations in the background level for spectral band 1 of magnitudes ranging from 2 to 3.5 digital numbers (DN). Similar variability is observed in all the other reflective bands, but with smaller magnitude in the range 0.5 to 2.5 DN. Observations of background reference levels show that line dependent variations in raw TM image data and in the associated calibration data can be measured and corrected within an operational environment by applying simple offset corrections on a line-by-line basis. The radiometric calibration procedure defined by the Canadian Center for Remote Sensing was revised accordingly in order to prevent striping in the output product.

  16. The importance and attainment of accurate absolute radiometric calibration

    NASA Technical Reports Server (NTRS)

    Slater, P. N.

    1984-01-01

    The importance of accurate absolute radiometric calibration is discussed by reference to the needs of those wishing to validate or use models describing the interaction of electromagnetic radiation with the atmosphere and earth surface features. The in-flight calibration methods used for the Landsat Thematic Mapper (TM) and the Systeme Probatoire d'Observation de la Terre, Haute Resolution visible (SPOT/HRV) systems are described and their limitations discussed. The questionable stability of in-flight absolute calibration methods suggests the use of a radiative transfer program to predict the apparent radiance, at the entrance pupil of the sensor, of a ground site of measured reflectance imaged through a well characterized atmosphere. The uncertainties of such a method are discussed.

  17. Polarization properties of FEL lamps as applied to radiometric calibration.

    PubMed

    Voss, Kenneth J; Belmar da Costa, Leonardo

    2016-11-01

    The polarization of the irradiance from several 1000 W FEL lamps was measured between 450 and 900 nm. These lamps are universally used as irradiance calibration standards in radiometric laboratories. The irradiance was polarized between 2.3% and 3.2%, with the polarization axis aligned with the coiled filament, nearly perpendicular to the lamp axis. We have presented a simple model of the filament that explains the degree of polarization and the plane of polarization, based on the polarized emissivity of tungsten, and gives an approximate value for this polarization. While the irradiance is polarized, this polarization does not significantly effect the polarization of the light when reflected from a Spectralon plaque (Labsphere, Inc.). The polarization of these lamps should be considered when these FEL lamps are used to characterize optical instruments, particularly grating spectrometers without polarization scrambling devices.

  18. Laboratory Measurement of Bidirectional Reflectance of Radiometric Tarps

    NASA Technical Reports Server (NTRS)

    Knowlton, Kelly

    2004-01-01

    This experiment measured the reflectance of tarps with ground instruments in order to check radiometric calibration, validate atmospheric correction, and predict at-sensor radiance for satellite instruments. The procedure of this experiment is as follows: 1) Assemble laboratory apparatus to duplicate ground reference measurement geometry and satellite measurement geometry; 2) Measure spectral radiance with Optronics OL 750 double monochromator/spectroradiometer; 3) Measure radiance of NIST-calibrated Spectralon panel irradiated by collimated light at incidence angle of calibrated reflectance (20 deg, 30 deg, 40 deg, or 50 deg), viewing normal to panel surface; 4) Measure radiance of Spectralon panel irradiated at incidence angle equal to solar zenith angle at time of overpass; 5) Calculate reflectance of Spectralon panel irradiated at solar zenith angle, viewing normal to panel surface (ground geometry).

  19. Validation of the Thematic Mapper radiometric and geometric correction algorithms

    NASA Technical Reports Server (NTRS)

    Fischel, D.

    1984-01-01

    The radiometric and geometric correction algorithms for Thematic Mapper are critical to subsequent successful information extraction. Earlier Landsat scanners, known as Multispectral Scanners, produce imagery which exhibits striping due to mismatching of detector gains and biases. Thematic Mapper exhibits the same phenomenon at three levels: detector-to-detector, scan-to-scan, and multiscan striping. The cause of these variations has been traced to variations in the dark current of the detectors. An alternative formulation has been tested and shown to be very satisfactory. Unfortunately, the Thematic Mapper detectors exhibit saturation effects suffered while viewing extensive cloud areas, and is not easily correctable. The geometric correction algorithm has been shown to be remarkably reliable. Only minor and modest improvements are indicated and shown to be effective.

  20. Airborne Millimeter-Wave Radiometric Observations of Cirrus Clouds

    NASA Technical Reports Server (NTRS)

    Wang, J. R.; Racette, P.

    1997-01-01

    This paper reports the first radiometric measurements of cirrus clouds in the frequency range of 89-325 GHz from a high-altitude aircraft flight. The measurements are conducted with a Millimeter-wave Imaging Radiometer (MIR) on board the NASA ER-2 aircraft over a region in northern Oklahoma. Aboard the same aircraft are a cloud lidar system and a multichannel radiometer operating at the visible and infrared wavelengths. The instrument ensemble is well suited for identifying cirrus clouds. It is shown that the depressions in brightness temperatures associated with a few intense cirrus clouds occur at all frequency channels of the MIR. Estimates of total ice water path of the cirrus clouds are derived from comparisons of radiative transfer calculations and observed brightness depressions.

  1. [In-flight absolute radiometric calibration of UAV multispectral sensor].

    PubMed

    Chen, Wei; Yan, Lei; Gou, Zhi-Yang; Zhao, Hong-Ying; Liu, Da-Ping; Duan, Yi-Ni

    2012-12-01

    Based on the data of the scientific experiment in Urad Front Banner for UAV Remote Sensing Load Calibration Field project, with the help of 6 hyperspectral radiometric targets with good Lambertian property, the wide-view multispectral camera in UAV was calibrated adopting reflectance-based method. The result reveals that for green, red and infrared channel, whose images were successfully captured, the linear correlation coefficients between the DN and radiance are all larger than 99%. In final analysis, the comprehensive error is no more than 6%. The calibration results demonstrate that the hyperspectral targets equipped by the calibration field are well suitable for air-borne multispectral load in-flight calibration. The calibration result is reliable and could be used in the retrieval of geophysical parameters.

  2. JPSS-1 VIIRS Pre-Launch Radiometric Performance

    NASA Technical Reports Server (NTRS)

    Oudrari, Hassan; McIntire, Jeff; Xiong, Xiaoxiong; Butler, James; Efremova, Boryana; Ji, Jack; Lee, Shihyan; Schwarting, Tom

    2015-01-01

    The Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the first Joint Polar Satellite System (JPSS) completed its sensor level testing on December 2014. The JPSS-1 (J1) mission is scheduled to launch in December 2016, and will be very similar to the Suomi-National Polar-orbiting Partnership (SNPP) mission. VIIRS instrument was designed to provide measurements of the globe twice daily. It is a wide-swath (3,040 kilometers) cross-track scanning radiometer with spatial resolutions of 370 and 740 meters at nadir for imaging and moderate bands, respectively. It covers the wavelength spectrum from reflective to long-wave infrared through 22 spectral bands [0.412 microns to 12.01 microns]. VIIRS observations are used to generate 22 environmental data products (EDRs). This paper will briefly describe J1 VIIRS characterization and calibration performance and methodologies executed during the pre-launch testing phases by the independent government team, to generate the at-launch baseline radiometric performance, and the metrics needed to populate the sensor data record (SDR) Look-Up-Tables (LUTs). This paper will also provide an assessment of the sensor pre-launch radiometric performance, such as the sensor signal to noise ratios (SNRs), dynamic range, reflective and emissive bands calibration performance, polarization sensitivity, bands spectral performance, response-vs-scan (RVS), near field and stray light responses. A set of performance metrics generated during the pre-launch testing program will be compared to the SNPP VIIRS pre-launch performance.

  3. JPSS-1 VIIRS pre-launch radiometric performance

    NASA Astrophysics Data System (ADS)

    Oudrari, Hassan; McIntire, Jeff; Xiong, Xiaoxiong; Butler, James; Efremova, Boryana; Ji, Qiang; Lee, Shihyan; Schwarting, Tom

    2015-09-01

    The Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the first Joint Polar Satellite System (JPSS) completed its sensor level testing on December 2014. The JPSS-1 (J1) mission is scheduled to launch in December 2016, and will be very similar to the Suomi-National Polar-orbiting Partnership (SNPP) mission. VIIRS instrument was designed to provide measurements of the globe twice daily. It is a wide-swath (3,040 km) cross-track scanning radiometer with spatial resolutions of 370 and 740 m at nadir for imaging and moderate bands, respectively. It covers the wavelength spectrum from reflective to long-wave infrared through 22 spectral bands [0.412 μm to 12.01 μm]. VIIRS observations are used to generate 22 environmental data products (EDRs). This paper will briefly describe J1 VIIRS characterization and calibration performance and methodologies executed during the pre-launch testing phases by the independent government team, to generate the at-launch baseline radiometric performance, and the metrics needed to populate the sensor data record (SDR) Look-Up-Tables (LUTs). This paper will also provide an assessment of the sensor pre-launch radiometric performance, such as the sensor signal to noise ratios (SNRs), dynamic range, reflective and emissive bands calibration performance, polarization sensitivity, bands spectral performance, response-vs-scan (RVS), near field and stray light responses. A set of performance metrics generated during the pre-launch testing program will be compared to the SNPP VIIRS pre-launch performance.

  4. IRCM spectral signature measurements instrumentation featuring enhanced radiometric accuracy

    NASA Astrophysics Data System (ADS)

    Lantagne, Stéphane; Prel, Florent; Moreau, Louis; Roy, Claude; Willers, Cornelius J.

    2015-10-01

    Hyperspectral Infrared (IR) signature measurements are performed in military applications including aircraft- and -naval vessel stealth characterization, detection/lock-on ranges, and flares efficiency characterization. Numerous military applications require high precision measurement of infrared signature characterization. For instance, Infrared Countermeasure (IRCM) systems and Infrared Counter-Countermeasure (IRCCM) system are continuously evolving. Infrared flares defeated IR guided seekers, IR flares became defeated by intelligent IR guided seekers and Jammers defeated the intelligent IR guided seekers [7]. A precise knowledge of the target infrared signature phenomenology is crucial for the development and improvement of countermeasure and counter-countermeasure systems and so precise quantification of the infrared energy emitted from the targets requires accurate spectral signature measurements. Errors in infrared characterization measurements can lead to weakness in the safety of the countermeasure system and errors in the determination of detection/lock-on range of an aircraft. The infrared signatures are analyzed, modeled, and simulated to provide a good understanding of the signature phenomenology to improve the IRCM and IRCCM technologies efficiency [7,8,9]. There is a growing need for infrared spectral signature measurement technology in order to further improve and validate infrared-based models and simulations. The addition of imagery to Spectroradiometers is improving the measurement capability of complex targets and scenes because all elements in the scene can now be measured simultaneously. However, the limited dynamic range of the Focal Plane Array (FPA) sensors used in these instruments confines the ranges of measurable radiance intensities. This ultimately affects the radiometric accuracy of these complex signatures. We will describe and demonstrate how the ABB hyperspectral imaging spectroradiometer features enhanced the radiometric accuracy

  5. Process development for automated solar cell and module production. Task 4: automated array assembly

    SciTech Connect

    Hagerty, J.J.

    1980-06-30

    The scope of work under this contract involves specifying a process sequence which can be used in conjunction with automated equipment for the mass production of solar cell modules for terrestrial use. This process sequence is then critically analyzed from a technical and economic standpoint to determine the technological readiness of each process step for implementation. The process steps are ranked according to the degree of development effort required and according to their significance to the overall process. Under this contract the steps receiving analysis were: back contact metallization, automated cell array layup/interconnect, and module edge sealing. For automated layup/interconnect both hard automation and programmable automation (using an industrial robot) were studied. The programmable automation system was then selected for actual hardware development. Economic analysis using the SAMICS system has been performed during these studies to assure that development efforts have been directed towards the ultimate goal of price reduction. Details are given. (WHK)

  6. Aviation Safety/Automation Program Conference

    NASA Technical Reports Server (NTRS)

    Morello, Samuel A. (Compiler)

    1990-01-01

    The Aviation Safety/Automation Program Conference - 1989 was sponsored by the NASA Langley Research Center on 11 to 12 October 1989. The conference, held at the Sheraton Beach Inn and Conference Center, Virginia Beach, Virginia, was chaired by Samuel A. Morello. The primary objective of the conference was to ensure effective communication and technology transfer by providing a forum for technical interchange of current operational problems and program results to date. The Aviation Safety/Automation Program has as its primary goal to improve the safety of the national airspace system through the development and integration of human-centered automation technologies for aircraft crews and air traffic controllers.

  7. RapidEye constellation relative radiometric accuracy measurement using lunar images

    NASA Astrophysics Data System (ADS)

    Steyn, Joe; Tyc, George; Beckett, Keith; Hashida, Yoshi

    2009-09-01

    The RapidEye constellation includes five identical satellites in Low Earth Orbit (LEO). Each satellite has a 5-band (blue, green, red, red-edge and near infrared (NIR)) multispectral imager at 6.5m GSD. A three-axes attitude control system allows pointing the imager of each satellite at the Moon during lunations. It is therefore possible to image the Moon from near identical viewing geometry within a span of 80 minutes with each one of the imagers. Comparing the radiometrically corrected images obtained from each band and each satellite allows a near instantaneous relative radiometric accuracy measurement and determination of relative gain changes between the five imagers. A more traditional terrestrial vicarious radiometric calibration program has also been completed by MDA on RapidEye. The two components of this program provide for spatial radiometric calibration ensuring that detector-to-detector response remains flat, while a temporal radiometric calibration approach has accumulated images of specific dry dessert calibration sites. These images are used to measure the constellation relative radiometric response and make on-ground gain and offset adjustments in order to maintain the relative accuracy of the constellation within +/-2.5%. A quantitative comparison between the gain changes measured by the lunar method and the terrestrial temporal radiometric calibration method is performed and will be presented.

  8. Technical Services Workstations. SPEC Kit 213.

    ERIC Educational Resources Information Center

    Brugger, Judith M., Comp.; And Others

    Technical services workstations (TSWs) are personal computers that have been customized for use in technical services departments. To gather information on their use and prevalence in research libraries, the Program for Cooperative Cataloging Standing Committee on Automation surveyed the 119 members of the Association of Research Libraries (ARL)…

  9. Instrumentation Automation for Concrete Structures: Report 2, Automation Hardware and Retrofitting Techniques, and Report 3, Available Data Collection and Reduction Software

    DTIC Science & Technology

    1987-06-01

    US-CE-CProperty ot the United States Government REPAIR, EVALUATION, MAINTENANCE, AND REHABILITATION RESEARCH PROGRAM TECHNICAL REPORT REMR-CS-5...INSTRUMENTATION AUTOMATION FOR CONCRETE STRUCTURES Report 2 AUTOMATION HARDWARE AND RETROFITTING TECHNIQUES by Aubrey Keeter, Byron Stonecypher...Vicksburg, Mississippi 39180-0631 The following two letters used as part of the number designating technical reports of research published under the Repair

  10. Radiometric Normalization of Large Airborne Image Data Sets Acquired by Different Sensor Types

    NASA Astrophysics Data System (ADS)

    Gehrke, S.; Beshah, B. T.

    2016-06-01

    Generating seamless mosaics of aerial images is a particularly challenging task when the mosaic comprises a large number of im-ages, collected over longer periods of time and with different sensors under varying imaging conditions. Such large mosaics typically consist of very heterogeneous image data, both spatially (different terrain types and atmosphere) and temporally (unstable atmo-spheric properties and even changes in land coverage). We present a new radiometric normalization or, respectively, radiometric aerial triangulation approach that takes advantage of our knowledge about each sensor's properties. The current implementation supports medium and large format airborne imaging sensors of the Leica Geosystems family, namely the ADS line-scanner as well as DMC and RCD frame sensors. A hierarchical modelling - with parameters for the overall mosaic, the sensor type, different flight sessions, strips and individual images - allows for adaptation to each sensor's geometric and radiometric properties. Additional parameters at different hierarchy levels can compensate radiome-tric differences of various origins to compensate for shortcomings of the preceding radiometric sensor calibration as well as BRDF and atmospheric corrections. The final, relative normalization is based on radiometric tie points in overlapping images, absolute radiometric control points and image statistics. It is computed in a global least squares adjustment for the entire mosaic by altering each image's histogram using a location-dependent mathematical model. This model involves contrast and brightness corrections at radiometric fix points with bilinear interpolation for corrections in-between. The distribution of the radiometry fixes is adaptive to each image and generally increases with image size, hence enabling optimal local adaptation even for very long image strips as typi-cally captured by a line-scanner sensor. The normalization approach is implemented in HxMap software. It has been

  11. Radiometric Calibration Assessment of Commercial High Spatial Resolution Multispectral Image Products

    NASA Technical Reports Server (NTRS)

    Holekamp, Kara; Aaron, David; Thome, Kurtis

    2006-01-01

    Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can better understand their properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, satellite at-sensor radiance values were compared to those estimated by each independent team member to determine the sensor's radiometric accuracy. The combined results of this evaluation provide the user community with an independent assessment of these commercially available high spatial resolution sensors' absolute calibration values.

  12. Improved Radiometric Based Method for Suppressing Impulse Noise from Corrupted Images

    NASA Astrophysics Data System (ADS)

    Wu, Changcheng; Zhao, Chunyu; Chen, Dayue

    A novel filter is introduced in this paper to improve the ability of radiometric based method on suppressing impulse noise. Firstly, a new method is introduced to design the impulsive weight by measuring how impulsive a pixel is. Then, the impulsive weight is combined with the radiometric weight to obtain the evaluated values on each pixel in the whole corrupted image. The impulsive weight is mainly designed to suppress the impulse noise, while the radiometric weight is mainly designed to protect the noise-free pixel. Extensive experiments demonstrate that the proposed algorithm can perform much better than other filters in terms of the quantitative and qualitative aspects.

  13. Radiometric Characterization of the IKONOS, QuickBird, and OrbView-3 Sensors

    NASA Technical Reports Server (NTRS)

    Holekamp, Kara

    2006-01-01

    Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can better understand their properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, satellite at-sensor radiance values were compared to those estimated by each independent team member to determine the sensor's radiometric accuracy. The combined results of this evaluation provide the user community with an independent assessment of these commercially available high spatial resolution sensors' absolute calibration values.

  14. Operational Test and Evaluation of Automated Construction Devices

    DTIC Science & Technology

    1990-04-01

    impact on project success. Thus, the motivation for trying to automate piping seems to be an effort to reduce costs, while the motivation to automate...Requirements. Technical Report, Purdue University, School of Civil Engineering. (1988) 2 3 Halpin, D. W.; Hijazi, A.; and Abou Risk, S. " Impact of...2 1.3 Motivation for Automation Research Today ............ 3 1.4 The Need

  15. Technical writing versus technical writing

    NASA Technical Reports Server (NTRS)

    Dillingham, J. W.

    1981-01-01

    Two terms, two job categories, 'technical writer' and 'technical author' are discussed in terms of industrial and business requirements and standards. A distinction between 'technical writing' and technical 'writing' is made. The term 'technical editor' is also considered. Problems inherent in the design of programs to prepare and train students for these jobs are discussed. A closer alliance between industry and academia is suggested as a means of preparing students with competent technical communication skills (especially writing and editing skills) and good technical skills.

  16. Automation in the Libraries of the City of Sao Paulo.

    ERIC Educational Resources Information Center

    McLean, D. D.

    1983-01-01

    Twenty selected Sao Paulo, Brazil, librarians who were interviewed indicated that, in their opinion, the development of library automation in this city is hampered by poor resources and cooperation, lack of professional and technical automation expertise, communication, and other psychological, organizational, and human related factors.…

  17. From Automation to Autonomy-Trends Towards Autonomous Combat Systems

    DTIC Science & Technology

    2000-04-01

    UNCLASSIFIED Defense Technical Information Center Compilation Part Notice ADPO10300 TITLE: From Automation to Autonomy-Trends Towards Autonomous ...Systems Concepts and Integration. [les Avancees en concepts systemes pour vehicules et en integration] To order the complete compilation report, use...part numbers comprise the compilation report: ADPO10300 thru ADP010339 UNCLASSIFIED K3-1 FROM AUTOMATION TO AUTONOMY -TRENDS TOWARDS AUTONOMOUS

  18. Automation in the Libraries of the City of Sao Paulo.

    ERIC Educational Resources Information Center

    McLean, D. D.

    1983-01-01

    Twenty selected Sao Paulo, Brazil, librarians who were interviewed indicated that, in their opinion, the development of library automation in this city is hampered by poor resources and cooperation, lack of professional and technical automation expertise, communication, and other psychological, organizational, and human related factors.…

  19. The Landsat Data Continuity Mission Operational Land Imager: Radiometric Performance

    NASA Technical Reports Server (NTRS)

    Markham, Brian; Dabney, Philip; Pedelty, Jeffrey

    2011-01-01

    The Operational Land Imager (OLI) is one of two instruments to fly on the Landsat Data Continuity Mission (LDCM), which is scheduled to launch in December 2012 to become the 8th in the series of Landsat satellites. The OLI images in the solar reflective part of the spectrum, with bands similar to bands 1-5, 7 and the panchromatic band on the Landsat-7 ETM+ instrument. In addition, it has a 20 nm bandpass spectral band at 443 nm for coastal and aerosol studies and a 30 nm band at 1375 nm to aid in cirrus cloud detection. Like ETM+, spatial resolution is 30 m in the all but the panchromatic band, which is 15 meters. OLI is a pushbroom radiometer with approximately 6000 detectors per 30 meter band as opposed to the 16 detectors per band on the whiskbroom ETM+. Data are quantized to 12 bits on OLI as opposed to 8 bits on ETM+ to take advantage of the improved signal to noise ratio provided by the pushbroom design. The saturation radiances are higher on OLI than ETM+ to effectively eliminate saturation issues over bright Earth targets. OLI includes dual solar diffusers for on-orbit absolute and relative (detector to detector) radiometric calibration. Additionally, OLI has 3 sets of on-board lamps that illuminate the OLI focal plane through the full optical system, providing additional checks on the OLI's response[l]. OLI has been designed and built by Ball Aerospace & Technology Corp. (BATC) and is currently undergoing testing and calibration in preparation for delivery in Spring 2011. Final pre-launch performance results should be available in time for presentation at the conference. Preliminary results will be presented below. These results are based on the performance of the Engineering Development Unit (EDU) that was radiometrically tested at the integrated instrument level in 2010 and assembly level measurements made on the flight unit. Signal-to-Noise (SNR) performance: One of the advantages of a pushbroom system is the increased dwell time of the detectors

  20. Landsat-7 ETM+ radiometric stability and absolute calibration

    USGS Publications Warehouse

    Markham, B.L.; Barker, J.L.; Barsi, J.A.; Kaita, E.; Thome, K.J.; Helder, D.L.; Palluconi, Frank Don; Schott, J.R.; Scaramuzza, P.; ,

    2002-01-01

    Launched in April 1999, the Landsat-7 ETM+ instrument is in its fourth year of operation. The quality of the acquired calibrated imagery continues to be high, especially with respect to its three most important radiometric performance parameters: reflective band instrument stability to better than ??1%, reflective band absolute calibration to better than ??5%, and thermal band absolute calibration to better than ??0.6 K. The ETM+ instrument has been the most stable of any of the Landsat instruments, in both the reflective and thermal channels. To date, the best on-board calibration source for the reflective bands has been the Full Aperture Solar Calibrator, which has indicated changes of at most -1.8% to -2.0% (95% C.I.) change per year in the ETM+ gain (band 4). However, this change is believed to be caused by changes in the solar diffuser panel, as opposed to a change in the instrument's gain. This belief is based partially on ground observations, which bound the changes in gain in band 4 at -0.7% to +1.5%. Also, ETM+ stability is indicated by the monitoring of desert targets. These image-based results for four Saharan and Arabian sites, for a collection of 35 scenes over the three years since launch, bound the gain change at -0.7% to +0.5% in band 4. Thermal calibration from ground observations revealed an offset error of +0.31 W/m 2 sr um soon after launch. This offset was corrected within the U. S. ground processing system at EROS Data Center on 21-Dec-00, and since then, the band 6 on-board calibration has indicated changes of at most +0.02% to +0.04% (95% C.I.) per year. The latest ground observations have detected no remaining offset error with an RMS error of ??0.6 K. The stability and absolute calibration of the Landsat-7 ETM+ sensor make it an ideal candidate to be used as a reference source for radiometric cross-calibrating to other land remote sensing satellite systems.

  1. Radiometric absolute noise-temperature measurement system features improved accuracy and calibration ease

    NASA Technical Reports Server (NTRS)

    Brown, W.; Ewen, H.; Haroules, G.

    1970-01-01

    Radiometric receiver system, which measures noise temperatures in degrees Kelvin, does not require cryogenic noise sources for routine operation. It eliminates radiometer calibration errors associated with RF attenuation measurements. Calibrated noise source is required only for laboratory adjustment and calibration.

  2. Simultaneous Inflight Spectral and Radiometric Calibration Validation of AVRIS and HYDICE Over Lunar Lake, Nevada

    NASA Technical Reports Server (NTRS)

    Chrien, Thomas; Green, Robert; Chovit, Chris; Faust, Jessica; Johnson, Howell; Basedow, Robert; Zalewski, Edward; Colwell, John

    1995-01-01

    An experiment to check the spectral and radiometric calibration of two sensors--the airborne visible/infrared imaging spectromenter (AVRIS) and the Hyperspectral digital image collection experiment (HYDICE)--is described.

  3. Flight Technology Improvement. [spaceborne optical radiometric instruments, attitude control, and electromechanical and power subsystems

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Shortcomings in spaceborne instrumentation technology are analyzed and recommendations are given for corrections and technology development. The technologies discussed are optical radiometric instruments and calibration, attitude control and determination, and electromechanical and power subsystems.

  4. Intra-annual NDVI validation of the Landsat 5 TM radiometric calibration

    USGS Publications Warehouse

    Chander, G.; Groeneveld, D.P.

    2009-01-01

    Multispectral data from the Landsat 5 (L5) Thematic Mapper (TM) sensor provide the backbone of the extensive archive of moderate‐resolution Earth imagery. Even after more than 24 years of service, the L5 TM is still operational. Given the longevity of the satellite, the detectors have aged and the sensor's radiometric characteristics have changed since launch. The calibration procedures and parameters in the National Land Archive Production System (NLAPS) have also changed with time. Revised radiometric calibrations in 2003 and 2007 have improved the radiometric accuracy of recently processed data. This letter uses the Normalized Difference Vegetation Index (NDVI) as a metric to evaluate the radiometric calibration. The calibration change has improved absolute calibration accuracy, consistency over time, and consistency with Landsat 7 (L7) Enhanced Thematic radiometry and will provide the basis for continued long‐term studies of the Earth's land surfaces.

  5. Phoretic and Radiometric Force Measurements on Microparticles in Microgravity Conditions

    NASA Technical Reports Server (NTRS)

    Davis, E. James

    1996-01-01

    Thermophoretic, diffusiophoretic and radiometric forces on microparticles are being measured over a wide range of gas phase and particle conditions using electrodynamic levitation of single particles to simulate microgravity conditions. The thermophoretic force, which arises when a particle exists in a gas having a temperature gradient, is measured by levitating an electrically charged particle between heated and cooled plates mounted in a vacuum chamber. The diffusiophoretic force arising from a concentration gradient in the gas phase is measured in a similar manner except that the heat exchangers are coated with liquids to establish a vapor concentration gradient. These phoretic forces and the radiation pressure force acting on a particle are measured directly in terms of the change in the dc field required to levitate the particle with and without the force applied. The apparatus developed for the research and the experimental techniques are discussed, and results obtained by thermophoresis experiments are presented. The determination of the momentum and energy accommodation coefficients associated with molecular collisions between gases molecules and particles and the measurement of the interaction between electromagnetic radiation and small particles are of particular interest.

  6. JPSS-1 VIIRS Pre-Launch Radiometric Performance

    NASA Technical Reports Server (NTRS)

    Oudrari, Hassan; Mcintire, Jeffrey; Xiong, Xiaoxiong; Butler, James; Ji, Qiang; Schwarting, Tom; Zeng, Jinan

    2015-01-01

    The first Joint Polar Satellite System (JPSS-1 or J1) mission is scheduled to launch in January 2017, and will be very similar to the Suomi-National Polar-orbiting Partnership (SNPP) mission. The Visible Infrared Imaging Radiometer Suite (VIIRS) on board the J1 spacecraft completed its sensor level performance testing in December 2014. VIIRS instrument is expected to provide valuable information about the Earth environment and properties on a daily basis, using a wide-swath (3,040 km) cross-track scanning radiometer. The design covers the wavelength spectrum from reflective to long-wave infrared through 22 spectral bands, from 0.412 m to 12.01 m, and has spatial resolutions of 370 m and 740 m at nadir for imaging and moderate bands, respectively. This paper will provide an overview of pre-launch J1 VIIRS performance testing and methodologies, describing the at-launch baseline radiometric performance as well as the metrics needed to calibrate the instrument once on orbit. Key sensor performance metrics include the sensor signal to noise ratios (SNRs), dynamic range, reflective and emissive bands calibration performance, polarization sensitivity, bands spectral performance, response-vs-scan (RVS), near field response, and stray light rejection. A set of performance metrics generated during the pre-launch testing program will be compared to the sensor requirements and to SNPP VIIRS pre-launch performance.

  7. Design, manufacture, and calibration of infrared radiometric blackbody sources

    SciTech Connect

    Byrd, D.A.; Michaud, F.D.; Bender, S.C.

    1996-04-01

    A Radiometric Calibration Station (RCS) is being assembled at the Los Alamos National Laboratories (LANL) which will allow for calibration of sensors with detector arrays having spectral capability from about 0.4-15 {mu}m. The configuration of the LANL RCS. Two blackbody sources have been designed to cover the spectral range from about 3-15 {mu}m, operating at temperatures ranging from about 180-350 K within a vacuum environment. The sources are designed to present a uniform spectral radiance over a large area to the sensor unit under test. The thermal uniformity requirement of the blackbody cavities has been one of the key factors of the design, requiring less than 50 mK variation over the entire blackbody surface to attain effective emissivity values of about 0.999. Once the two units are built and verified to the level of about 100 mK at LANL, they will be sent to the National Institute of Standards and Technology (NIST), where at least a factor of two improvement will be calibrated into the blackbody control system. The physical size of these assemblies will require modifications of the existing NIST Low Background Infrared (LBIR) Facility. LANL has constructed a bolt-on addition to the LBIR facility that will allow calibration of our large aperture sources. Methodology for attaining the two blackbody sources at calibrated levels of performance equivalent to present state of the art will be explained in the following.

  8. Advanced radiometric and interferometric milimeter-wave scene simulations

    NASA Technical Reports Server (NTRS)

    Hauss, B. I.; Moffa, P. J.; Steele, W. G.; Agravante, H.; Davidheiser, R.; Samec, T.; Young, S. K.

    1993-01-01

    Smart munitions and weapons utilize various imaging sensors (including passive IR, active and passive millimeter-wave, and visible wavebands) to detect/identify targets at short standoff ranges and in varied terrain backgrounds. In order to design and evaluate these sensors under a variety of conditions, a high-fidelity scene simulation capability is necessary. Such a capability for passive millimeter-wave scene simulation exists at TRW. TRW's Advanced Radiometric Millimeter-Wave Scene Simulation (ARMSS) code is a rigorous, benchmarked, end-to-end passive millimeter-wave scene simulation code for interpreting millimeter-wave data, establishing scene signatures and evaluating sensor performance. In passive millimeter-wave imaging, resolution is limited due to wavelength and aperture size. Where high resolution is required, the utility of passive millimeter-wave imaging is confined to short ranges. Recent developments in interferometry have made possible high resolution applications on military platforms. Interferometry or synthetic aperture radiometry allows the creation of a high resolution image with a sparsely filled aperture. Borrowing from research work in radio astronomy, we have developed and tested at TRW scene reconstruction algorithms that allow the recovery of the scene from a relatively small number of spatial frequency components. In this paper, the TRW modeling capability is described and numerical results are presented.

  9. Estimation of Radiometric Calibration Coefficients of EGYPTSAT-1 Sensor

    NASA Astrophysics Data System (ADS)

    Nasr, A. H.; El Leithy, B. M.; Badr, H. S.; Centeno, J.

    2012-07-01

    Sensors usually must be calibrated as part of a measurement system. Calibration may include the procedure of correcting the transfer of the sensor, using the reference measurements, in such a way that a specific input-output relation can be guaranteed with a certain accuracy and under certain conditions. It is necessary to perform a calibration to relate the output signal precisely to the physical input signal (e.g., the output Digital Numbers (DNs) to the absolute units of at-sensor spectral radiance). Generic calibration data associated with Egyptsat-1 sensor are not provided by the manufacturer. Therefore, this study was conducted to estimate Egyptsat-1 sensor specific calibration data and tabulates the necessary constants for its different multispectral bands. We focused our attention on the relative calibration between Egyptsat-1 and Spot-4 sensors for their great spectral similarity. The key idea is to use concurrent correlation of signals received at both sensors in the same day (i.e., sensors are observing the same phenomenon). Calibration formula constructed from Spot-4 sensor is used to derive the calibration coefficients for Egyptsat-1. A brief overview of the radiometric calibration coefficients retrieval procedures is presented. A reasonable estimate of the overall calibration coefficient is obtained. They have been used to calibrate reflectances of Egyptsat-1 sensor. Further updates to evaluate and improve the retrieved calibration data are being investigated.

  10. Radiometric STFT Analysis of PDV recordings and detectivity limit

    NASA Astrophysics Data System (ADS)

    Bozier, Olivier; Prudhomme, Gabriel; Mercier, Patrick; Berthe, Laurent

    2015-06-01

    Photonic Doppler Velocimetry is a plug-and-play and versatile diagnostic used in dynamic physic experiments to measure velocities. When signals are analyzed using a Short-Time Fourier Transform, multiple velocities can be distinguished: by example, the velocities of moving particle-cloud appear on spectrograms. In order to estimate the back-scattering fluxes of target, we propose an original approach ``PDV Radiometric analysis'' resulting in an expression of time-velocity spectrograms coded in power units. Experiments involving micron-sized particles raise the issue of detection limit; particle-size limit is very difficult to evaluate. From the quantification of noise sources, we derivate an estimation of the spectrogram noise leading to a detectivity limit. It may be compared to back-scattering and collected power from a particle, which is increasing with its size. At least, some results from laser-shock accelerated particles using two different PDV systems are compared: it may show the improvement of sensitivity.

  11. Automatic Ship Recognition Using A Passive Radiometric Sensor

    NASA Astrophysics Data System (ADS)

    Keng, Janmin

    1982-03-01

    Automatic ship recognition is of interest in such problems as over-the-horizon surface surveillance and targeting, long range air targeting, and satellite ocean surveillance. Our approach is model-driven. It uses the fact that the wake caused by a cruising ship has a higher temperature profile than the surrounding water background. In addition, we distinguish between the active wake and the turbulent water surrounding the ship. Furthermore, the temperature of the ship itself is usually lower than that of the ocean. Finally, we make use of the knowledge of ship sizes, convoy patterns and other information concerning ships traveling in formation. An image from a radiometric sensor forms the basis of the analysis. Edge detection and region association techniques are used to locate a "zone of activity", a region of the image that contains the ship. Grey level histogram analysis of the zone is then used to categorize pixels into "ship", "wake", and "water". Results of experiments using this technique are presented.

  12. Advanced radiometric and interferometric milimeter-wave scene simulations

    NASA Astrophysics Data System (ADS)

    Hauss, B. I.; Moffa, P. J.; Steele, W. G.; Agravante, H.; Davidheiser, R.; Samec, T.; Young, S. K.

    1993-12-01

    Smart munitions and weapons utilize various imaging sensors (including passive IR, active and passive millimeter-wave, and visible wavebands) to detect/identify targets at short standoff ranges and in varied terrain backgrounds. In order to design and evaluate these sensors under a variety of conditions, a high-fidelity scene simulation capability is necessary. Such a capability for passive millimeter-wave scene simulation exists at TRW. TRW's Advanced Radiometric Millimeter-Wave Scene Simulation (ARMSS) code is a rigorous, benchmarked, end-to-end passive millimeter-wave scene simulation code for interpreting millimeter-wave data, establishing scene signatures and evaluating sensor performance. In passive millimeter-wave imaging, resolution is limited due to wavelength and aperture size. Where high resolution is required, the utility of passive millimeter-wave imaging is confined to short ranges. Recent developments in interferometry have made possible high resolution applications on military platforms. Interferometry or synthetic aperture radiometry allows the creation of a high resolution image with a sparsely filled aperture. Borrowing from research work in radio astronomy, we have developed and tested at TRW scene reconstruction algorithms that allow the recovery of the scene from a relatively small number of spatial frequency components. In this paper, the TRW modeling capability is described and numerical results are presented.

  13. Effects on Spacecraft Radiometric Data at Superior Solar Conjunction

    NASA Technical Reports Server (NTRS)

    Morley, Trevor; Budnik, Frank

    2007-01-01

    During 2006, three ESA interplanetary spacecraft, Rosetta, Mars Express (MEX) and Venus Express (VEX), passed through superior solar conjunction. For all three spacecraft, the noise in the post-fit range-rate residuals from the orbit determination was analysed. At small Sun-Earth-Probe (SEP) angles the level was almost two orders of magnitude higher than normal. The main objective was to characterize the Doppler (rangerate) noise as a function of SEP angle. At least then the range-rate data can be appropriately weighted within the orbit determination so that the solution uncertainties are realistic. For VEX, some intervals of particularly noisy Doppler data could be correlated with unusual solar activity. For Rosetta, the biases in the range data residuals were analysed with the aim of improving the model used for calibrating the signal delay due to the solar plasma. The model, which originally had fixed coefficients, was adjusted to achieve better fits to the data. Even the relatively small Doppler biases were well represented. Using the improved model, the electron density at 20 solar radii was compared with earlier results obtained by radio science studies using Voyager 2 and Ulysses radiometric data. There is some evidence for a dependency of the density on the phase within the 11 years solar cycle.

  14. Investigation of Aerodynamic and Aerodynamic and Radiometric Land Surface Temperatures

    NASA Technical Reports Server (NTRS)

    Crago, Richard D.; Friedl, Mark; Kustas, William; Wang, Ye-Qiao

    2003-01-01

    The overall goal of the project was to reconcile the difference between T(sub s,r) and T(sub aero), while maintaining consistency within models and with theory and data. The project involved collaboration between researchers at Bucknell University, Boston University, University of mode Island, and the USDNARS Hydrology Laboratory. This report focuses on the work done at Bucknell, which used an analytical continuous-source flux model developed by Crago (1998), based on work by Brutsaert and Sugita (1996) to generate fluxes at all levels of the canopy. Named ALARM [Analytical Land- Atmosphere-Radiometer Model] by Suleiman and Crago (2002), the model assumes the foliage has an exponential vertical temperature profile. The same profile is felt by the within-canopy turbulence and 'seen" by a radiometer viewing the surface from any zenith view angle. ALARM converts radiometric surface temperatures taken from any view angle into a clearly-defined version of Taero called the equivalent isothermal surface temperature T(sub s,j), and then calculates the sensible heat flux H using Monin-Obukhov similarity theory. This allows remotely sensed Ts,r measurements to be used to produce high quality sensible and latent heat flux estimates, or to validate or update the surface temperature produced by SVATs in climate or mesoscale models.

  15. Optimized mapping of radiometric quantities into OpenGL

    NASA Astrophysics Data System (ADS)

    Lorenzo, Maximo; Jacobs, Eddie L.; Moulton, J. R., Jr.; Liu, Jesse

    1999-07-01

    Physically realistic synthesis of FLIR imagery requires intensive phenomenology calculations of the spectral band thermal emission and reflection from scene elements in the database. These calculations predict the heat conduction, convection, and radiation exchange between scene elements and the environment. Balancing this requirement is the need for imagery to be presented to a display in a timely fashion, often in real time. In order to support these conflicting requirements, some means of overcoming the gap between real time and high fidelity must be achieved. Over the past several years, the US Army Night Vision and Electronic Sensors Directorate (NVESD) has been developing a real-time forward looking infrared sensor simulation known as Paint the Night (PTN). As part of this development, NVESD has explored schemes for optimizing signature models and for mapping model radiometric output into parameters compatible with OpenGL, real-time rendering architectures. Relevant signature and mapping optimization issues are discussed, and a current NVESD PTN real-time implementation scheme is presented.

  16. History of Solar Radiometry and the World Radiometric Reference

    NASA Astrophysics Data System (ADS)

    Fröhlich, C.

    1991-01-01

    The history of solar radiometry since the first pyrheliometer of Pouillet is presented. After the invention of the Ångström and the Smithsonian pyrheliometers around the turn of this century two different "scales" were in use. Comparisons with absolute cavity radiometers developed in America and Europe have been performed since about 1910 which show remarkably accurate measurements in terms of the SI units. However, these results have never been accepted and several rules have been established to reference radiation measurements in the meteorological community and to remedy the unsatisfactory fact of having different "scales". Unfortunately none of these rules led to a reference close to the SI units of irradiance, confusing the issue even more. With the advent of modern absolute radiometers in the late 1960s the situation improved and led to the definition of the World Radiometric Reference in use by the meteorological community since 1981. This reference has an estimated accuracy of 0,3% and guarantees the worldwide homogeneity of radiation measurements within 0,1% precision.

  17. NERO: General concept of a NEO radiometric observatory

    NASA Astrophysics Data System (ADS)

    Cellino, A.; Somma, R.; Tommasi, L.; Paolinetti, R.; Muinonen, K.; Virtanen, J.; Tedesco, E. F.

    NERO (Near-Earth Objects Radiometric Observatory) is one of the six studies for possible missions dedicated to near-Earth objects, that were funded by the ESA in 2002-2003. NERO is a further development of previous studies already submitted to ESA (Sysiphos,Spaceguard-1). The general concept is that a small satellite equipped with both a CCD for visible wavelengths and an array for thermal IR measurements around 10 microns would be an ideal platform for simultaneously obtaining two of the major objectives of current NEO science, namely the physical characterization of the objects and the discovery of NEOs which are difficult to detect because they have orbits entirely or partly interior to the Earth's orbit. The NERO study included a comprehensive analysis of the advantages and drawbacks of different orbital options for the satellite (including L2 of Earth and L2 of Venus) and a preliminary simulation of the effectiveness in deriving reliable orbits of the newly detected objects. The main results of this study, including also a preliminary design of the payload (optics, detectors, cooling system, etc.) are briefly summarized.

  18. Radiometric sensor performance model including atmospheric and IR clutter effects

    NASA Astrophysics Data System (ADS)

    Richter, Rudolf; Davis, Joel S.; Duggin, Michael J.

    1997-06-01

    The computer code SENSAT developed for radiometric investigations in remote sensing was extended to include two statistical clutter models of infrared background and the prediction of the target detection probability. The first one is based on the standard deviation of scene clutter estimated from scene data, the second one is based on the power spectral density of different classes of IR background as a function of temporal or spatial frequency. The overall code consists of modules describing the optoelectronic sensor (optics, detector, signal processor), a radiative transfer code (MODTRAN) to include the atmospheric effects, and the scene module consisting of target and background. The scene is evaluated for a certain pixel at a time. However, a sequence of pixels can be simulated by varying the range, view angle, atmospheric condition, or the clutter level. The target consists of one or two subpixel surface elements, the remaining part of the pixels represents background. Multiple paths, e.g. sun-ground-target-sensor, can also be selected. An expert system, based upon the IDL language, provides user-friendly input menus, performs consistency checks, and submits the required MODTRAN and SENSAT runs. A sample case of the detection probability of a sub-pixel target in a marine cluttered background is discussed.

  19. Proceedings of the LLNL Technical Women`s Symposium

    SciTech Connect

    von Holtz, E.

    1993-12-31

    This report documents events of the LLNL Technical Women`s Symposium. Topics include; future of computer systems, environmental technology, defense and space, Nova Inertial Confinement Fusion Target Physics, technical communication, tools and techniques for biology in the 1990s, automation and robotics, software applications, materials science, atomic vapor laser isotope separation, technical communication, technology transfer, and professional development workshops.

  20. Selection of chemotherapy for patient treatment utilizing a radiometric versus a cloning system

    SciTech Connect

    Von Hoff, D.D.; Forseth, B.J.; Turner, J.N.; Clark, G.M.; Warfel, L.E.

    1986-01-01

    From the 1950s to the 1970s, a number of in vitro systems that measured inhibition of glucose metabolism were used to predict the responsiveness of patients' tumors to chemotherapy. In vitro-in vivo correlations were excellent, with true positive predictions ranging from 68% to 96% and true negative predictions of 95% to 100%. The radiometric system is a new in vitro technique that measures the conversion of 14C-glucose to 14CO2. The system already has been utilized to screen prospective new antineoplastic agents for cytotoxicity. The present study was undertaken to determine if the radiometric system might be used to predict correctly the responsiveness of an individual patient's tumor to single-agent or combination-agent chemotherapy. Fifty-six tumor specimens were divided and tested for drug sensitivity in the radiometric system and a conventional human tumor clonning system. Overall, there was a significant correlation between in vitro and in vivo results for the conventional cloning system (P = 0.03). However, there was no significant relationship between in vitro and in vivo results for the radiometric system. The radiometric system consistently failed to predict the tumor's clinical sensitivity to single agents. A radiometric system is not useful in predicting the responsiveness of a patient's tumor to single agent chemotherapy and is not a replacement for the more biologically attractive human tumor cloning system.

  1. A multi-channel radiometric profiler of temperature, humidity and cloud liquid.

    SciTech Connect

    Ware, R.; Carpenter, R.; Guldner, J.; Liljegren, J.; Nehrkorn, T.; Solheim, F.; Vandenberghe, F.; Environmental Research; Radiometrics Corp.; Univ. Corp. for Atmospheric Research; Weather Decision Technologies Inc.; Atmospheric and Environmental Research Inc.; National Center for Atmospheric Research

    2003-07-31

    A microwave radiometer is described that provides continuous thermodynamic (temperature, water vapor, and moisture) soundings during clear and cloudy conditions. The radiometric profiler observes radiation intensity at 12 microwave frequencies, along with zenith infrared and surface meteorological measurements. Historical radiosonde and neural network or regression methods are used for profile retrieval. We compare radiometric, radiosonde, and forecast soundings and evaluate the accuracy of radiometric temperature and water vapor soundings on the basis of statistical comparison with radiosonde soundings. We find that radiometric soundings are equivalent in accuracy to radiosonde soundings when used in numerical weather forecasting. A case study is described that demonstrates improved fog forecasting on the basis of variational assimilation of radiometric soundings. The accuracy of radiometric cloud liquid soundings is evaluated by comparison with cloud liquid sensors carried by radiosondes. Accurate high-resolution three-dimensional water vapor and wind analysis is described on the basis of assimilation of simulated thermodynamic and wind soundings along with GPS slant delays. Examples of mobile thermodynamic and wind profilers are shown. Thermodynamic profiling, particularly when combined with wind profiling and slant GPS, provides continuous atmospheric soundings for improved weather and dispersion forecasting.

  2. Evaluation of relative radiometric correction techniques on Landsat 8 OLI sensor data

    NASA Astrophysics Data System (ADS)

    Novelli, Antonio; Caradonna, Grazia; Tarantino, Eufemia

    2016-08-01

    The quality of information derived from processed remotely sensed data may depend upon many factors, mostly related to the extent data acquisition is influenced by atmospheric conditions, topographic effects, sun angle and so on. The goal of radiometric corrections is to reduce such effects in order enhance the performance of change detection analysis. There are two approaches to radiometric correction: absolute and relative calibrations. Due to the large amount of free data products available, absolute radiometric calibration techniques may be time consuming and financially expensive because of the necessary inputs for absolute calibration models (often these data are not available and can be difficult to obtain). The relative approach to radiometric correction, known as relative radiometric normalization, is preferred with some research topics because no in situ ancillary data, at the time of satellite overpasses, are required. In this study we evaluated three well known relative radiometric correction techniques using two Landsat 8 - OLI scenes over a subset area of the Apulia Region (southern Italy): the IR-MAD (Iteratively Reweighted Multivariate Alteration Detection), the HM (Histogram Matching) and the DOS (Dark Object Subtraction). IR-MAD results were statistically assessed within a territory with an extremely heterogeneous landscape and all computations performed in a Matlab environment. The panchromatic and thermal bands were excluded from the comparisons.

  3. USSR Report, Cybernetics Computers and Automation Technology

    DTIC Science & Technology

    1985-09-05

    CONTENTS GENERAL Artificial Intelligence : Is It Possible? CGermogen Sergeyevich Pospelov, Interview; ZHURNALIST, No 7, Jul 84) 1 Leningrad...Automation in Tbilisi^^ ^ JPRS~UCO85~006 5 September 1985 GENERAL ARTIFICIAL INTELLIGENCE : IS IT POSSIBLE? Moscow ZHURNALIST in Russian No 7...8217 Scientific Council on the Problem "Artificial Intelligence ," by Yu. Samoylov, candidate of technical sciences, scientific reviewer, MOSKOVSKIYE

  4. Space station automation study. Volume 1: Executive summary. Autonomous systems and assembly

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The space station automation study (SSAS) was to develop informed technical guidance for NASA personnel in the use of autonomy and autonomous systems to implement space station functions. The initial step taken by NASA in organizing the SSAS was to form and convene a panel of recognized expert technologists in automation, space sciences and aerospace engineering to produce a space station automation plan.

  5. Automated species identification: why not?

    PubMed Central

    Gaston, Kevin J; O'Neill, Mark A

    2004-01-01

    Where possible, automation has been a common response of humankind to many activities that have to be repeated numerous times. The routine identification of specimens of previously described species has many of the characteristics of other activities that have been automated, and poses a major constraint on studies in many areas of both pure and applied biology. In this paper, we consider some of the reasons why automated species identification has not become widely employed, and whether it is a realistic option, addressing the notions that it is too difficult, too threatening, too different or too costly. Although recognizing that there are some very real technical obstacles yet to be overcome, we argue that progress in the development of automated species identification is extremely encouraging that such an approach has the potential to make a valuable contribution to reducing the burden of routine identifications. Vision and enterprise are perhaps more limiting at present than practical constraints on what might possibly be achieved. PMID:15253351

  6. Team-Centered Perspective for Adaptive Automation Design

    NASA Technical Reports Server (NTRS)

    Prinzel, Lawrence J., III

    2003-01-01

    Automation represents a very active area of human factors research. The journal, Human Factors, published a special issue on automation in 1985. Since then, hundreds of scientific studies have been published examining the nature of automation and its interaction with human performance. However, despite a dramatic increase in research investigating human factors issues in aviation automation, there remain areas that need further exploration. This NASA Technical Memorandum describes a new area of automation design and research, called adaptive automation. It discusses the concepts and outlines the human factors issues associated with the new method of adaptive function allocation. The primary focus is on human-centered design, and specifically on ensuring that adaptive automation is from a team-centered perspective. The document shows that adaptive automation has many human factors issues common to traditional automation design. Much like the introduction of other new technologies and paradigm shifts, adaptive automation presents an opportunity to remediate current problems but poses new ones for human-automation interaction in aerospace operations. The review here is intended to communicate the philosophical perspective and direction of adaptive automation research conducted under the Aerospace Operations Systems (AOS), Physiological and Psychological Stressors and Factors (PPSF) project.

  7. The Dome Automations of ATA50 and MASS-DIMM Telescopes for DAG Project

    NASA Astrophysics Data System (ADS)

    Dogan, E.; Celik, H. I.; Ozbaldan, E. E.; Guney, Y.; Yesilyaprak, C.

    2016-12-01

    In the scope of Eastern Anatolia Observatory (DAG) Project, The DAG Technical Team has carried out various automation studies like dome, camera, atmospherical equipments, etc. The domes of ATA50 and MASS-DIMM Telescopes have almost similar opening systems. Both telescopes will run as robotic very soon; therefore it's mandatory and inevitable to make the automations of their domes. The automation studies as its electronics and software developed by DAG Technical Team are presented.

  8. The absolute radiometric calibration of the Landsat 8 Operational Land Imager using the reflectance-based approach and the Radiometric Calibration Test Site (RadCaTS)

    NASA Astrophysics Data System (ADS)

    Czapla-Myers, Jeffrey; Anderson, Nikolaus; Thome, Kurtis; Biggar, Stuart

    2014-10-01

    Landsat 8 was launched on 11 February 2013 as the newest platform in the Landsat program. It contains two Earthobserving instruments, one of which is the Operational Land Imager (OLI). OLI includes an onboard radiometric calibration system that is used to monitor changes in its responsivity throughout the mission lifetime, and it consists of Spectralon solar diffuser panels as well as tungsten lamp assemblies. External techniques are used to monitor both OLI and its calibration system, and they include lunar views, side slither maneuvers of the satellite, and ground-based vicarious calibration. This work presents the absolute radiometric calibration results for Landsat 8 OLI that were obtained using two ground-based measurement techniques. The first is the reflectance-based approach, where measurements of atmospheric and surface properties are made during a Landsat 8 overpass, and it requires personnel to be on site during the time of measurement. The second uses the Radiometric Calibration Test Site (RadCaTS), which was developed by the Remote Sensing Group in the College of Optical Sciences at the University of Arizona so that radiometric calibration data can be collected without the requirement of on-site personnel. It allows more data to be collected annually, which increases the temporal sampling of trending results.

  9. "Technical" Writing vs. Technical "Writing."

    ERIC Educational Resources Information Center

    Dillingham, J. W.

    Technical writers must have a working knowledge of technology in order to rearrange material others provide, but they do not have the expertise needed to originate materials; that is the job of the technical author. Another job function is that of technical editor--a person who can write, can perform the policy making tasks of an editor, and who…

  10. Radiometric Calibration Techniques for Signal-of-Opportunity Reflectometers

    NASA Technical Reports Server (NTRS)

    Piepmeier, Jeffrey R.; Shah, Rashmi; Deshpande, Manohar; Johnson, Carey

    2014-01-01

    Bi-static reflection measurements utilizing global navigation satellite service (GNSS) or other signals of opportunity (SoOp) can be used to sense ocean and terrestrial surface properties. End-to-end calibration of GNSS-R has been performed using well-characterized reflection surface (e.g., water), direct path antenna, and receiver gain characterization. We propose an augmented approach using on-board receiver electronics for radiometric calibration of SoOp reflectometers utilizing direct and reflected signal receiving antennas. The method calibrates receiver and correlator gains and offsets utilizing a reference switch and common noise source. On-board electronic calibration sources, such as reference switches, noise diodes and loop-back circuits, have shown great utility in stabilizing total power and correlation microwave radiometer and scatterometer receiver electronics in L-band spaceborne instruments. Application to SoOp instruments is likely to bring several benefits. For example, application to provide short and long time scale calibration stability of the direct path channel, especially in low signal-to-noise ratio configurations, is directly analogous to the microwave radiometer problem. The direct path channel is analogous to the loopback path in a scatterometer to provide a reference of the transmitted power, although the receiver is independent from the reflected path channel. Thus, a common noise source can be used to measure the gain ratio of the two paths. Using these techniques long-term (days to weeks) calibration stability of spaceborne L-band scatterometer and radiometer has been achieved better than 0.1. Similar long-term stability would likely be needed for a spaceborne reflectometer mission to measure terrestrial properties such as soil moisture.

  11. Radiometric method for determining solubility of organic solvents in water

    SciTech Connect

    Lo, J.M.; Tseng, C.L.; Yang, J.Y.

    1986-06-01

    Cobalt-60 labeled cobalt(III) pyrrolidinecarbodithioate (/sup 60/Co(PDC)/sub 3/) has a peculiar stability during storage in organic solvent and when its organic solution is shaken with an aqueous solution containing different acids or ions. Using these characteristics, the authors have attempted to use /sup 60/Co(PDC)/sub 3/ as a radioagent for determining solubilities of various organic solvents in water. The radioagent was first dissolved in the organic solvent under investigation before pure water was added. The solution mixture was shaken vigorously in order to let the organic phase contact with water sufficiently. Some of the organic solvent would dissolve in water after shaking, resulting in volume reduction of the organic phase. However, the radioagent was found not to accompany the organic solvent molecules going into water; i.e., all the radioactivity of /sup 60/Co(PDC)/sub 3/ would be retained in the organic phase. Solubility of the organic solvent in water therefore can be calculated from the value of the volume change of the organic phase divided by the water volume. Direct measurement of a small change in volume of organic phase with high accuracy is generally very difficult; alternatively, the authors have measured the specific activities of /sup 60/Co(PDC)/sub 3/ (cpm/mL) in the original and the final organic solutions, and the counting results were used to estimate the decrease in volume of the organic phase. Several commonly used organic solvents were selected to test the applicability of the proposed radiometric method. The solubilities of the organic solvents selected for this study range from very small values (10/sup -4/) to relatively large values (10/sup -2/), 6 references, 1 table.

  12. Radiometric Calibration of the Earth Observing System's Imaging Sensors

    NASA Technical Reports Server (NTRS)

    Slater, Philip N. (Principal Investigator)

    1997-01-01

    The work on the grant was mainly directed towards developing new, accurate, redundant methods for the in-flight, absolute radiometric calibration of satellite multispectral imaging systems and refining the accuracy of methods already in use. Initially the work was in preparation for the calibration of MODIS and HIRIS (before the development of that sensor was canceled), with the realization it would be applicable to most imaging multi- or hyper-spectral sensors provided their spatial or spectral resolutions were not too coarse. The work on the grant involved three different ground-based, in-flight calibration methods reflectance-based radiance-based and diffuse-to-global irradiance ratio used with the reflectance-based method. This continuing research had the dual advantage of: (1) developing several independent methods to create the redundancy that is essential for the identification and hopefully the elimination of systematic errors; and (2) refining the measurement techniques and algorithms that can be used not only for improving calibration accuracy but also for the reverse process of retrieving ground reflectances from calibrated remote-sensing data. The grant also provided the support necessary for us to embark on other projects such as the ratioing radiometer approach to on-board calibration (this has been further developed by SBRS as the 'solar diffuser stability monitor' and is incorporated into the most important on-board calibration system for MODIS)- another example of the work, which was a spin-off from the grant funding, was a study of solar diffuser materials. Journal citations, titles and abstracts of publications authored by faculty, staff, and students are also attached.

  13. Precise quantitation of PAIgG: A new radiometric microtechnique

    SciTech Connect

    Schwartz, K.A.; Gauger, J.A.; Davis, J.M. )

    1990-03-01

    We report the development of a radiometric assay for platelet-bound IgG that is both sensitive and quantitative. The assay utilized 96-well millititer plates incorporating a 0.2 microns filter membrane in the bottom. A 125I-labeled monoclonal antihuman IgG, as a secondary antibody, detected the platelet-bound human IgG. Since 5 x 10(6) platelets were used for each assay, tests for platelet-bound IgG can be performed on persons with severe thrombocytopenia. For the detection of circulating antiplatelet alloantibodies, as little as 10 microliters of platelet-free plasma per assay is required. Antiplatelet IgG was quantitated by using anti-PIA1 antibody that was purified with affinity and elution and DEAE chromatography. This purified antiplatelet antibody was labeled with 125I and was used to determine the binding ratio of secondary antibody to primary antibody. Under our standard conditions, this ratio was found to be stable at approximately 0.35 over the sensitivity range of the assay. The assay can detect approximately 200 molecules of human IgG per platelet (0.1 ng of secondary antibody bound per 5 x 10(6) platelets). It has a linear range from 0 to 7,000 molecules per platelet. Quantitation of anti-PIA1 binding for platelets stored for up to 6 months under refrigeration showed no change in number of PIA1 binding sites. Clinical studies showed that 18 of 19 ITP patients had an increased number of IgG molecules per platelet as did patients with malignancy and drug-induced immune thrombocytopenia. Patients who had received multiple platelet transfusions had antiplatelet antibody in their plasma. Normal amounts of PAIgG were observed in platelets and plasma of patients with nonimmune thrombocytopenia.

  14. Reintroducing radiometric surface temperature into the Penman-Monteith formulation

    NASA Astrophysics Data System (ADS)

    Mallick, Kaniska; Boegh, Eva; Trebs, Ivonne; Alfieri, Joseph G.; Kustas, William P.; Prueger, John H.; Niyogi, Dev; Das, Narendra; Drewry, Darren T.; Hoffmann, Lucien; Jarvis, Andrew J.

    2015-08-01

    Here we demonstrate a novel method to physically integrate radiometric surface temperature (TR) into the Penman-Monteith (PM) formulation for estimating the terrestrial sensible and latent heat fluxes (H and λE) in the framework of a modified Surface Temperature Initiated Closure (STIC). It combines TR data with standard energy balance closure models for deriving a hybrid scheme that does not require parameterization of the surface (or stomatal) and aerodynamic conductances (gS and gB). STIC is formed by the simultaneous solution of four state equations and it uses TR as an additional data source for retrieving the "near surface" moisture availability (M) and the Priestley-Taylor coefficient (α). The performance of STIC is tested using high-temporal resolution TR observations collected from different international surface energy flux experiments in conjunction with corresponding net radiation (RN), ground heat flux (G), air temperature (TA), and relative humidity (RH) measurements. A comparison of the STIC outputs with the eddy covariance measurements of λE and H revealed RMSDs of 7-16% and 40-74% in half-hourly λE and H estimates. These statistics were 5-13% and 10-44% in daily λE and H. The errors and uncertainties in both surface fluxes are comparable to the models that typically use land surface parameterizations for determining the unobserved components (gS and gB) of the surface energy balance models. However, the scheme is simpler, has the capabilities for generating spatially explicit surface energy fluxes and independent of submodels for boundary layer developments. This article was corrected on 27 AUG 2015. See the end of the full text for details.

  15. Landsat-7 EMT+ On-Orbit Radiometric Calibration

    NASA Technical Reports Server (NTRS)

    Markham, Brian L.; Barker, J. L.; Kaita, E.; Seiferth, J.; Morfitt, Ron

    1999-01-01

    Landsat-7 was launched on April 15, 1999 and completed its on orbit initialization and verification period on June 28, 1999. The ETM+ payload is similar to the TM sensors on previous Landsat satellites and incorporates two new devices to improve its absolute radiometric calibration. The Full Aperture Solar Calibrator (FASC) is a deployable diffuser panel. This device has been deployed 9 times to date, with a normal deployment schedule of once per month. The initial analysis of the FASC data has given absolute calibration results within 5% of the prelaunch integrating sphere calibrations and a range of variation of 2% between dates. The Partial Aperture Solar Calibrator (PASC), is a set of auxiliary optics that allows the ETM+ to view the sun through a reduced aperture. Data have normally been acquired on a daily basis with the PASC. Initial results with the PASC were encouraging, despite some unexpected saturation in the shortest wavelength band. The response of the ETM+ short wavelength (silicon) bands to the PASC increased initially and has begun to decrease in some of these bands. The longer wavelength (InSb) bands have shown up to 30% oscillations that vary between detectors within the band. Studies are ongoing to better characterize the response to the PASC. The ETM+ also incorporates an internal calibrator (IC), a shutter that oscillates in front of the focal plane that directs light from the internal calibrator lamps to the focal plane. The responses to this device are also varying, though differently than the PASC results. Both the IC and PASC results are attributable to the calibration devices as opposed to the ETM+ itself.

  16. Geostatistical analysis as applied to two environmental radiometric time series.

    PubMed

    Dowdall, Mark; Lind, Bjørn; Gerland, Sebastian; Rudjord, Anne Liv

    2003-03-01

    This article details the results of an investigation into the application of geostatistical data analysis to two environmental radiometric time series. The data series employed consist of 99Tc values for seaweed (Fucus vesiculosus) and seawater samples taken as part of a marine monitoring program conducted on the coast of northern Norway by the Norwegian Radiation Protection Authority. Geostatistical methods were selected in order to provide information on values of the variables at unsampled times and to investigate the temporal correlation exhibited by the data sets. This information is of use in the optimisation of future sampling schemes and for providing information on the temporal behaviour of the variables in question that may not be obtained during a cursory analysis. The results indicate a high degree of temporal correlation within the data sets, the correlation for the seawater and seaweed data being modelled with an exponential and linear function, respectively. The semi-variogram for the seawater data indicates a temporal range of correlation of approximately 395 days with no apparent random component to the overall variance structure and was described best by an exponential function. The temporal structure of the seaweed data was best modelled by a linear function with a small nugget component. Evidence of drift was present in both semi-variograms. Interpolation of the data sets using the fitted models and a simple kriging procedure were compared, using a cross-validation procedure, with simple linear interpolation. Results of this exercise indicate that, for the seawater data, the kriging procedure outperformed the simple interpolation with respect to error distribution and correlation of estimates with actual values. Using the unbounded linear model with the seaweed data produced estimates that were only marginally better than those produced by the simple interpolation.

  17. [Equipment components and system board for an automated microscopy system].

    PubMed

    Medovyĭ, V S; Parpara, A A; Sokolinskiĭ, B Z; Dem'ianov, V L

    2007-01-01

    Characteristics of modern equipment components for general- or special-purpose modular systems of automated microscopy are considered. Medical, technical, and economic assessment of various configurations of automated microscopy systems is performed. These systems can be used in telemedicine and hematological, cytological, and parasitologic analysis. Schemes for optimization of the configuration of automated microscopy systems are described. The structure of MECOS-Ts2 automated microscopy systems is considered. The system board of MECOS-Ts2 systems makes it possible to use a wide variety of equipment components and software from different manufacturers.

  18. Experimental methods of indoor millimeter-wave radiometric imaging for personnel concealed contraband detection

    NASA Astrophysics Data System (ADS)

    Hu, Taiyang; Xiao, Zelong; Li, Hao; Lv, Rongchuan; Lu, Xuan

    2014-11-01

    The increasingly emerging terrorism attacks and violence crimes around the world have posed severe threats to public security, so carrying out relevant research on advanced experimental methods of personnel concealed contraband detection is crucial and meaningful. All of the advantages of imaging covertly, avoidance of interference with other systems, intrinsic property of being safe to persons under screening , and the superior ability of imaging through natural or manmade obscurants, have significantly combined to enable millimeter-wave (MMW) radiometric imaging to offer great potential in personnel concealed contraband detection. Based upon the current research status of MMW radiometric imaging and urgent demands of personnel security screening, this paper mainly focuses on the experimental methods of indoor MMW radiometric imaging. The reverse radiation noise resulting from super-heterodyne receivers seriously affects the image experiments carried out at short range, so both the generation mechanism and reducing methods of this noise are investigated. Then, the benefit of sky illumination no longer exists for the indoor radiometric imaging, and this leads to the decrease in radiometric temperature contrast between target and background. In order to enhance the radiometric temperature contrast for improving indoor imaging performance, the noise illumination technique is adopted in the indoor imaging scenario. In addition, the speed and accuracy of concealed contraband detection from acquired MMW radiometric images are usually restricted to the deficiencies in traditional artificial interpretation by security inspectors, thus an automatic recognition and location algorithm by integrating improved Fuzzy C-means clustering with moment invariants is put forward. A series of original results are also presented to demonstrate the significance and validity of these methods.

  19. Automation tools for flexible aircraft maintenance.

    SciTech Connect

    Prentice, William J.; Drotning, William D.; Watterberg, Peter A.; Loucks, Clifford S.; Kozlowski, David M.

    2003-11-01

    This report summarizes the accomplishments of the Laboratory Directed Research and Development (LDRD) project 26546 at Sandia, during the period FY01 through FY03. The project team visited four DoD depots that support extensive aircraft maintenance in order to understand critical needs for automation, and to identify maintenance processes for potential automation or integration opportunities. From the visits, the team identified technology needs and application issues, as well as non-technical drivers that influence the application of automation in depot maintenance of aircraft. Software tools for automation facility design analysis were developed, improved, extended, and integrated to encompass greater breadth for eventual application as a generalized design tool. The design tools for automated path planning and path generation have been enhanced to incorporate those complex robot systems with redundant joint configurations, which are likely candidate designs for a complex aircraft maintenance facility. A prototype force-controlled actively compliant end-effector was designed and developed based on a parallel kinematic mechanism design. This device was developed for demonstration of surface finishing, one of many in-contact operations performed during aircraft maintenance. This end-effector tool was positioned along the workpiece by a robot manipulator, programmed for operation by the automated planning tools integrated for this project. Together, the hardware and software tools demonstrate many of the technologies required for flexible automation in a maintenance facility.

  20. An Enhanced Algorithm for Automatic Radiometric Harmonization of High-Resolution Optical Satellite Imagery Using Pseudoinvariant Features and Linear Regression

    NASA Astrophysics Data System (ADS)

    Langheinrich, M.; Fischer, P.; Probeck, M.; Ramminger, G.; Wagner, T.; Krauß, T.

    2017-05-01

    The growing number of available optical remote sensing data providing large spatial and temporal coverage enables the coherent and gapless observation of the earth's surface on the scale of whole countries or continents. To produce datasets of that size, individual satellite scenes have to be stitched together forming so-called mosaics. Here the problem arises that the different images feature varying radiometric properties depending on the momentary acquisition conditions. The interpretation of optical remote sensing data is to a great extent based on the analysis of the spectral composition of an observed surface reflection. Therefore the normalization of all images included in a large image mosaic is necessary to ensure consistent results concerning the application of procedures to the whole dataset. In this work an algorithm is described which enables the automated spectral harmonization of satellite images to a reference scene. As the stable and satisfying functionality of the proposed algorithm was already put to operational use to process a high number of SPOT-4/-5, IRS LISS-III and Landsat-5 scenes in the frame of the European Environment Agency's Copernicus/GMES Initial Operations (GIO) High-Resolution Layer (HRL) mapping of the HRL Forest for 20 Western, Central and (South)Eastern European countries, it is further evaluated on its reliability concerning the application to newer Sentinel-2 multispectral imaging products. The results show that the algorithm is comparably efficient for the processing of satellite image data from sources other than the sensor configurations it was originally designed for.

  1. Underway sensing of radiometric properties utilizing a novel sub-hull installation on R/V SONNE

    NASA Astrophysics Data System (ADS)

    Zielinski, O.; Rüssmeier, N.; Garaba, S. P.; Voss, D.

    2016-12-01

    Understanding light interaction with biogeochemical constituents in the marine environment has improved in the last few years due to small, fast, automated and affordable optical tools. Ocean color observations are dependent on ambient sunlight, wind speed influencing sea surface reflected glint, instrument self shading, sensor accuracy, sensitivity as well as spatial and spectral resolution influencing our abilities in sensing oceanic processes. In this study we present a new method useful in collecting radiometric information, namely upwelling radiance from a platform submerged in a novel hydrographic sub-hull of a research vessel. The information analyzed here was obtained during a recent field campaign in the Northwestern European shelf seas aboard the new German research vessel SONNE. A comparison of the measurements from this approach with a free falling hyperspectral profiler was conducted to determine the degree of uncertainty that results from ship shadow. We observed intensity deviations in a range of about 30% compared to profiling measurements, which can be attributed to instrument shading and environmental perturbations. A form-fitting algorithm was adapted to receive corresponding depths with identical spectral shape indicating an equivalent light path of 22 m for the sub-hull installation. Remote sensing reflectance was then calculated by normalizing the upwelling radiance with the downward solar irradiance. During an east to west transect in the North Sea we successfully applied the above method while cruising at a maximum speed up of 12 knots, resolving the mixing zone of CDOM (colored dissolved organic matter) dominant Baltic waters towards the open North Sea.

  2. Improved Thermal-Vacuum Compatible Flat Plate Radiometric Souce for System-Level Testing of Optical Sensors

    NASA Technical Reports Server (NTRS)

    Schwarz, Mark A.; Kent, Craig J.; Bousquet, Robert; Brown, Steven W.

    2015-01-01

    This work describes the development of an improved vacuum compatible flat plate radiometric source used for characterizing and calibrating remote optical sensors, in situ, throughout their testing period. The original flat plate radiometric source was developed for use by the VIIRS instrument during the NPOESS Preparatory Project (NPP). Following this effort, the FPI has had significant upgrades in order to improve both the radiometric throughput and uniformity. Results of the VIIRS testing with the reconfigured FPI are reported and discussed.

  3. Automated mass spectrometer grows up

    SciTech Connect

    McInteer, B.B.; Montoya, J.G.; Stark, E.E.

    1984-01-01

    In 1980 we reported the development of an automated mass spectrometer for large scale batches of samples enriched in nitrogen-15 as ammonium salts. Since that time significant technical progress has been made in the instrument. Perhaps more significantly, administrative and institutional changes have permitted the entire effort to be transferred to the private sector from its original base at the Los Alamos National Laboratory. This has ensured the continuance of a needed service to the international scientific community as revealed by a development project at a national laboratory, and is an excellent example of beneficial technology transfer to private industry.

  4. Microwave and Millimeter Wave Forward Modeling Results from the 2004 North Slope of Alaska Arctic Winter Radiometric Experiment

    SciTech Connect

    Westwater, E.R.; Cimini, D.; Klein, M.; Leuski, V.; Mattioli, V.; Gasiewski, A.J.; Dowlatshahi, S.; Liljegren, J.S.; Lesht, B.M.; Shaw, J.A.

    2005-03-18

    The 2004 Arctic Winter Radiometric Experiment was conducted at the North Slope of Alaska (NSA) Atmospheric Radiation Measurement (ARM) Program field site near Barrow, Alaska from March 9 to April 9, 2004. The goals of the experiment were: to study the microwave and millimeter wave radiometric response to water vapor and clouds during cold and dry conditions; to obtain data for forward model studies at frequencies ranging from 22.235 to 400 GHz, to demonstrate new Environmental Technology Laboratory's (ETL) radiometric receiver and calibration technology and to compare both radiometric and in situ measurements of water vapor.

  5. Laboratory automation in clinical bacteriology: what system to choose?

    PubMed

    Croxatto, A; Prod'hom, G; Faverjon, F; Rochais, Y; Greub, G

    2016-03-01

    Automation was introduced many years ago in several diagnostic disciplines such as chemistry, haematology and molecular biology. The first laboratory automation system for clinical bacteriology was released in 2006, and it rapidly proved its value by increasing productivity, allowing a continuous increase in sample volumes despite limited budgets and personnel shortages. Today, two major manufacturers, BD Kiestra and Copan, are commercializing partial or complete laboratory automation systems for bacteriology. The laboratory automation systems are rapidly evolving to provide improved hardware and software solutions to optimize laboratory efficiency. However, the complex parameters of the laboratory and automation systems must be considered to determine the best system for each given laboratory. We address several topics on laboratory automation that may help clinical bacteriologists to understand the particularities and operative modalities of the different systems. We present (a) a comparison of the engineering and technical features of the various elements composing the two different automated systems currently available, (b) the system workflows of partial and complete laboratory automation, which define the basis for laboratory reorganization required to optimize system efficiency, (c) the concept of digital imaging and telebacteriology, (d) the connectivity of laboratory automation to the laboratory information system, (e) the general advantages and disadvantages as well as the expected impacts provided by laboratory automation and (f) the laboratory data required to conduct a workflow assessment to determine the best configuration of an automated system for the laboratory activities and specificities.

  6. Radiometric Characterization Results for the IKONOS, Quickbird, and OrbView-3 Sensor

    NASA Technical Reports Server (NTRS)

    Holekamp, Kara; Aaron, David; Thome, Kurtis

    2006-01-01

    Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities better understand commercial imaging satellite properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, the NASA Applied Sciences Directorate (ASD) at Stennis Space Center established a commercial satellite imaging radiometric calibration team consisting of three independent groups: NASA ASD, the University of Arizona Remote Sensing Group, and South Dakota State University. Each group independently determined the absolute radiometric calibration coefficients of available high-spatial-resolution commercial 4-band multispectral products, in the visible though near-infrared spectrum, from GeoEye(tradeMark) (formerly SpaceImaging(Registered TradeMark)) IKONOS, DigitalGlobe(Regitered TradeMark) QuickBird, and GeoEye (formerly ORBIMAGE(Registered TradeMark) OrbView. Each team member employed some variant of reflectance-based vicarious calibration approach, requiring ground-based measurements coincident with image acquisitions and radiative transfer calculations. Several study sites throughout the United States that covered a significant portion of the sensor's dynamic range were employed. Satellite at-sensor radiance values were compared to those estimated by each independent team member to evaluate the sensor's radiometric accuracy. The combined results of this evaluation provide the user community with an independent assessment of these sensors' absolute calibration values.

  7. Vicarious absolute radiometric calibration of GF-2 PMS2 sensor using permanent artificial targets in China

    NASA Astrophysics Data System (ADS)

    Liu, Yaokai; Li, Chuanrong; Ma, Lingling; Wang, Ning; Qian, Yonggang; Tang, Lingli

    2016-10-01

    GF-2, launched on August 19 2014, is one of the high-resolution land resource observing satellite of the China GF series satellites plan. The radiometric performance evaluation of the onboard optical pan and multispectral (PMS2) sensor of GF-2 satellite is very important for the further application of the data. And, the vicarious absolute radiometric calibration approach is one of the most useful way to monitor the radiometric performance of the onboard optical sensors. In this study, the traditional reflectance-based method is used to vicarious radiometrically calibrate the onboard PMS2 sensor of GF-2 satellite using three black, gray and white reflected permanent artificial targets located in the AOE Baotou site in China. Vicarious field calibration campaign were carried out in the AOE-Baotou calibration site on 22 April 2016. And, the absolute radiometric calibration coefficients were determined with in situ measured atmospheric parameters and surface reflectance of the permanent artificial calibration targets. The predicted TOA radiance of a selected desert area with our determined calibrated coefficients were compared with the official distributed calibration coefficients. Comparison results show a good consistent and the mean relative difference of the multispectral channels is less than 5%. Uncertainty analysis was also carried out and a total uncertainty with 3.87% is determined of the TOA radiance.

  8. (abstract) Deep Space Network Radiometric Remote Sensing Program

    NASA Technical Reports Server (NTRS)

    Walter, Steven J.

    1994-01-01

    Planetary spacecraft are viewed through a troposphere that absorbs and delays radio signals propagating through it. Tropospheric water, in the form of vapor, cloud liquid,and precipitation , emits radio noise which limits satellite telemetry communication link performance. Even at X-band, rain storms have severely affected several satellite experiments including a planetary encounter. The problem will worsen with DSN implementation of Ka-band becausecommunication link budgets will be dominated by tropospheric conditions. Troposphere-induced propagation delays currently limit VLBI accuracy and are significant sources of error for Doppler tracking. Additionally, the success of radio science programs such as satellite gravity wave experiments and atmospheric occultation experiments depends on minimizing the effect of watervapor-induced prop agation delays. In order to overcome limitations imposed by the troposphere, the Deep Space Network has supported a program of radiometric remote sensing. Currently, water vapor radiometers (WVRs) and microwave temperature profilers (MTPs) support many aspects of the Deep Space Network operations and research and development programs. Their capability to sense atmospheric water, microwave sky brightness, and atmospheric temperature is critical to development of Ka-band telemetry systems, communication link models, VLBI, satellite gravity waveexperiments, and r adio science missions. During 1993, WVRs provided data for propagation mode development, supp orted planetary missions, and demonstrated advanced tracking capability. Collection of atmospheric statistics is necessary to model and predict performance of Ka-band telemetry links, antenna arrays, and radio science experiments. Since the spectrum of weather variations has power at very long time scales, atmospheric measurements have been requested for periods ranging from one year to a decade at each DSN site. The resulting database would provide reliable statistics on daily

  9. (abstract) Deep Space Network Radiometric Remote Sensing Program

    NASA Technical Reports Server (NTRS)

    Walter, Steven J.

    1994-01-01

    Planetary spacecraft are viewed through a troposphere that absorbs and delays radio signals propagating through it. Tropospheric water, in the form of vapor, cloud liquid,and precipitation , emits radio noise which limits satellite telemetry communication link performance. Even at X-band, rain storms have severely affected several satellite experiments including a planetary encounter. The problem will worsen with DSN implementation of Ka-band becausecommunication link budgets will be dominated by tropospheric conditions. Troposphere-induced propagation delays currently limit VLBI accuracy and are significant sources of error for Doppler tracking. Additionally, the success of radio science programs such as satellite gravity wave experiments and atmospheric occultation experiments depends on minimizing the effect of watervapor-induced prop agation delays. In order to overcome limitations imposed by the troposphere, the Deep Space Network has supported a program of radiometric remote sensing. Currently, water vapor radiometers (WVRs) and microwave temperature profilers (MTPs) support many aspects of the Deep Space Network operations and research and development programs. Their capability to sense atmospheric water, microwave sky brightness, and atmospheric temperature is critical to development of Ka-band telemetry systems, communication link models, VLBI, satellite gravity waveexperiments, and r adio science missions. During 1993, WVRs provided data for propagation mode development, supp orted planetary missions, and demonstrated advanced tracking capability. Collection of atmospheric statistics is necessary to model and predict performance of Ka-band telemetry links, antenna arrays, and radio science experiments. Since the spectrum of weather variations has power at very long time scales, atmospheric measurements have been requested for periods ranging from one year to a decade at each DSN site. The resulting database would provide reliable statistics on daily

  10. Sunglint Detection for Unmanned and Automated Platforms

    PubMed Central

    Garaba, Shungudzemwoyo Pascal; Schulz, Jan; Wernand, Marcel Robert; Zielinski, Oliver

    2012-01-01

    We present an empirical quality control protocol for above-water radiometric sampling focussing on identifying sunglint situations. Using hyperspectral radiometers, measurements were taken on an automated and unmanned seaborne platform in northwest European shelf seas. In parallel, a camera system was used to capture sea surface and sky images of the investigated points. The quality control consists of meteorological flags, to mask dusk, dawn, precipitation and low light conditions, utilizing incoming solar irradiance (ES) spectra. Using 629 from a total of 3,121 spectral measurements that passed the test conditions of the meteorological flagging, a new sunglint flag was developed. To predict sunglint conspicuous in the simultaneously available sea surface images a sunglint image detection algorithm was developed and implemented. Applying this algorithm, two sets of data, one with (having too much or detectable white pixels or sunglint) and one without sunglint (having least visible/detectable white pixel or sunglint), were derived. To identify the most effective sunglint flagging criteria we evaluated the spectral characteristics of these two data sets using water leaving radiance (LW) and remote sensing reflectance (RRS). Spectral conditions satisfying ‘mean LW (700–950 nm) < 2 mW·m−2·nm−1·Sr−1’ or alternatively ‘minimum RRS (700–950 nm) < 0.010 Sr−1’, mask most measurements affected by sunglint, providing an efficient empirical flagging of sunglint in automated quality control.

  11. Detecting payload performance based on relative radiometric characteristic: case of the optical sensors

    NASA Astrophysics Data System (ADS)

    Han, Jie; Li, Shengyang; Zhang, Tao; Qin, Bangyong

    2016-10-01

    In this paper, we propose a novel algorithm for accurately estimating the degree of radiometric non-uniformity in remote sensing images. The algorithm was tested on high-quality images and heavily striping images, and quantitative analyses were conducted to evaluate the performance for each band by measuring the radiometric non-uniformity of the images. The results demonstrated that the proposed algorithm exhibits high accuracy and stability compared with traditional algorithms. The radiometric performance of TianGong-1 short-wave infrared images was calculated using this new method, and it was highly correlated with the solar angle, pitch angle and refrigerator thermal according to the Apriori algorithm. Based on these results, we have proposed a strategy for restricting increases in striping.

  12. Lack of clinical relevance in routine final subcultures of radiometrically negative BACTEC blood culture vials

    SciTech Connect

    Plorde, J.J.; Carlson, L.G.; Dau, M.E.

    1982-11-01

    During a 38-month period, 10,106 blood specimens were received in the laboratory for culture. These were inoculated into 26,424 vials and processed using the BACTEC radiometric detection system. Of these vials, 1,914 were eventually found to be microbiologically positive. Isolates from 836 vials were judged to be contaminants. In the remaining 1,078 vials, growth was first detected visually or radiometrically in 1,062 and by final subculture in 16. Growth from these sixteen bottles represented 12 clinically significant bacteremic episodes in as many patients. In nine of these episodes, other culture vials from the same patient were positive radiometrically. Therefore, 358 of 361 (99.2%) bacteremic episodes were detected without the benefit of routine final subcultures. The three patients whose bacteremia was missed were diagnosed clinically and placed on appropriate therapy prior to the detection of the bacteremias by final subculture.

  13. Radiometric Calibration of Mars HiRISE High Resolution Imagery Based on Fpga

    NASA Astrophysics Data System (ADS)

    Hou, Yifan; Geng, Xun; Xing, Shuai; Tang, Yonghe; Xu, Qing

    2016-06-01

    Due to the large data amount of HiRISE imagery, traditional radiometric calibration method is not able to meet the fast processing requirements. To solve this problem, a radiometric calibration system of HiRISE imagery based on field program gate array (FPGA) is designed. The montage gap between two channels caused by gray inconsistency is removed through histogram matching. The calibration system is composed of FPGA and DSP, which makes full use of the parallel processing ability of FPGA and fast computation as well as flexible control characteristic of DSP. Experimental results show that the designed system consumes less hardware resources and the real-time processing ability of radiometric calibration of HiRISE imagery is improved.

  14. Absolute Radiometric Calibration of ALS Intensity Data: Effects on Accuracy and Target Classification

    PubMed Central

    Kaasalainen, Sanna; Pyysalo, Ulla; Krooks, Anssi; Vain, Ants; Kukko, Antero; Hyyppä, Juha; Kaasalainen, Mikko

    2011-01-01

    Radiometric calibration of airborne laser scanning (ALS) intensity data aims at retrieving a value related to the target scattering properties, which is independent on the instrument or flight parameters. The aim of a calibration procedure is also to be able to compare results from different flights and instruments, but practical applications are sparsely available, and the performance of calibration methods for this purpose needs to be further assessed. We have studied the radiometric calibration with data from three separate flights and two different instruments using external calibration targets. We find that the intensity data from different flights and instruments can be compared to each other only after a radiometric calibration process using separate calibration targets carefully selected for each flight. The calibration is also necessary for target classification purposes, such as separating vegetation from sand using intensity data from different flights. The classification results are meaningful only for calibrated intensity data. PMID:22346660

  15. Preparation of a new autonomous instrumented radiometric calibration site: Gobabeb, Namib Desert

    NASA Astrophysics Data System (ADS)

    Greenwell, Claire; Bialek, Agnieszka; Marks, Amelia; Woolliams, Emma; Berthelot, Béatrice; Meygret, Aimé; Marcq, Sébastien; Bouvet, Marc; Fox, Nigel

    2015-10-01

    A new permanently instrumented radiometric calibration site for high/medium resolution imaging satellite sensors is currently under development, focussing on the visible and near infra-red parts of the spectrum. The site will become a European contribution to the Committee on Earth Observation Satellites (CEOS) initiative RadCalNet (Radiometric Calibration Network). The exact location of the permanent monitoring instrumentation will be defined following the initial site characterisation. The new ESA/CNES RadCalNet site will have a robust uncertainty budget and its data fully SI traceable through detailed characterisation and calibration by NPL of the instruments and artefacts to be used on the site. This includes a CIMEL sun photometer (the permanent instrumentation) an ASD FieldSpec spectroradiometer, Gonio Radiometric Spectrometer System (GRASS), and reference reflectance standards.

  16. Radiometric selective inhibition tests for differentiation of Mycobacterium tuberculosis, Mycobacterium bovis, and other mycobacteria.

    PubMed Central

    Gross, W M; Hawkins, J E

    1985-01-01

    In the context of a busy reference laboratory, radiometric selective inhibition tests were evaluated for rapid differentiation of Mycobacterium tuberculosis and Mycobacterium bovis and of the M. tuberculosis complex from other mycobacteria. p-Nitro-alpha-acetylamino-beta-hydroxypropiophenone at 5 micrograms and hydroxylamine hydrochloride at 62.5 and 125 micrograms per ml of 7H12 medium were used to separate the M. tuberculosis complex from other mycobacteria (MOTT bacilli). Since it is important epidemiologically to distinguish M. tuberculosis from M. bovis, susceptibility to 1 microgram of thiophene-2-carboxylic acid per ml was also determined radiometrically. By using these three agents as selective inhibitors, M. tuberculosis, M. bovis, and MOTT bacilli were differentiated with a high degree of specificity by a BACTEC radiometric procedure. Results of tests performed on clinical isolates submitted on solid medium to our reference laboratory were available within 5 days. PMID:3921561

  17. Artifact correction and absolute radiometric calibration techniques employed in the Landsat 7 image assessment system

    USGS Publications Warehouse

    Boncyk, Wayne C.; Markham, Brian L.; Barker, John L.; Helder, Dennis

    1996-01-01

    The Landsat-7 Image Assessment System (IAS), part of the Landsat-7 Ground System, will calibrate and evaluate the radiometric and geometric performance of the Enhanced Thematic Mapper Plus (ETM +) instrument. The IAS incorporates new instrument radiometric artifact correction and absolute radiometric calibration techniques which overcome some limitations to calibration accuracy inherent in historical calibration methods. Knowledge of ETM + instrument characteristics gleaned from analysis of archival Thematic Mapper in-flight data and from ETM + prelaunch tests allow the determination and quantification of the sources of instrument artifacts. This a priori knowledge will be utilized in IAS algorithms designed to minimize the effects of the noise sources before calibration, in both ETM + image and calibration data.

  18. TECHNICAL EDUCATION.

    ERIC Educational Resources Information Center

    FRIGIOLA, NICHOLAS F.

    THE CONSENSUS OF OUR NATION'S LEADERS AFFIRMS THAT THE COUNTRY'S GREATEST TECHNICAL EDUCATION VOID IS IN THE AREA BETWEEN THE 12TH GRADE AND THE BACCALAUREATE DEGREE. THE IMPACT OF ACCELERATED PROGRESS IN TECHNOLOGICAL ACHIEVEMENTS MAKES TECHNICAL EDUCATION MANDATORY IF THE MANPOWER SHORTAGE IS NOT TO BECOME A NATIONAL EMERGENCY. BECAUSE NEARLY 80…

  19. NASA IKONOS Multispectral Radiometric Calibration and 3-Year Temporal Stability Assessment

    NASA Technical Reports Server (NTRS)

    Pagnutti, Mary; Carver, David; Holekamp, Kara; Ryan, Robert; Zanoni, Vicki; Thome, Kurtis; Schiller, Stephen; Aaran, David

    2003-01-01

    Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can place confidence in the imagery they use and can fully understand its properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other system. In addition, the user community has little or no insight into the design and operation of commercial sensors or into the methods involved in generating commercial products. To address this calibration need, the NASA Stennis Space Center (SSC) Earth Science Applications (ESA) Directorate established a commercial satellite imaging radiometric calibration team consisting of three independent groups: NASA, SSC,ESA, the University of Arizona Remote Sensing Group, and South Dacota State University. Each group determined the absolute radiometric calibration coefficients of the Space Imaging IKONOS 4-band, 4 m multispectral product covering the visible through near-infrared spectral region. For a three year period beginning in 2000, each team employed some variant of a reflectance-based vicarious calibration approach, requiring ground-based measurements coincident with IKONOS image acquisitions and radiative transfer calculations. Several study sites throughout the United States were employed that covered nearly the entire dynamic range of the IKONOS sensor. IKONOS at-sensor radiance values were compared to those estimated by each independent group to determine the IKONOS sensor's radiometric accuracy and stability. Over 10 individual vicariously determined at-sensor radiance estimates were used each year. When combined, these estimates provided a high-precision radiometric gain calibration coefficient. No significant calibration offset was observed. The results of this evaluation provide the scientific community with an independent assessment of the IKONOS sensor's absolute calibration and temporal stability over the 3

  20. Autonomy and Automation

    NASA Technical Reports Server (NTRS)

    Shively, Jay

    2017-01-01

    A significant level of debate and confusion has surrounded the meaning of the terms autonomy and automation. Automation is a multi-dimensional concept, and we propose that Remotely Piloted Aircraft Systems (RPAS) automation should be described with reference to the specific system and task that has been automated, the context in which the automation functions, and other relevant dimensions. In this paper, we present definitions of automation, pilot in the loop, pilot on the loop and pilot out of the loop. We further propose that in future, the International Civil Aviation Organization (ICAO) RPAS Panel avoids the use of the terms autonomy and autonomous when referring to automated systems on board RPA. Work Group 7 proposes to develop, in consultation with other workgroups, a taxonomy of Levels of Automation for RPAS.

  1. Bibliographic Networks and Microcomputer Applications for Aerospace and Defense Scientific and Technical Information.

    ERIC Educational Resources Information Center

    Hartt, Richard W.

    This report discusses the characteristics, operations, and automation requirements of technical libraries providing services to organizations involved in aerospace and defense scientific and technical work, and describes the Local Automation Model project. This on-going project is designed to demonstrate the concept of a fully integrated library…

  2. Overview of current technology in MMW radiometric sensors for law enforcement applications

    NASA Astrophysics Data System (ADS)

    Ferris, David D., Jr.; Currie, Nicholas C.

    2000-07-01

    This paper discusses the current state-of-the-art in millimeter-wave radiometric imagers being developed for law enforcement use within the United States. The most prevalent application at present is the detection of concealed weapons (guns, knives, etc.) with a secondary application involving the detection of drugs and explosives. Three main topics will be addressed: the phenomenology of concealed weapon detection at millimeter wavelengths, the promise and short comings of first generation radiometric imagers, and the characteristics of second generation systems currently under development.

  3. Radiometric-microbiologic assay of niacin using Kloeckera brevis: analysis of human blood and food

    SciTech Connect

    Guilarte, T.R.; Pravlik, K.

    1983-12-01

    Kloeckera brevis, a yeast, was used as the test organism for the development of a radiometric-microbiologic (RMA) assay for niacin. The assay was determined to be sensitive to the 2 ng niacin per vial level and specific for the biologically active forms of this vitamin. The method was shown to be simple, accurate, and precise in the analysis of niacin in human blood and food. The application of the radiometric technique eliminates some of the problems encountered with conventional turbidimetric-microbiologic assay.

  4. Airborne lidar and radiometric observations of PBL- and low clouds

    NASA Technical Reports Server (NTRS)

    Flamant, P. H.; Valentin, R.; Pelon, J.

    1992-01-01

    lidar and narrowbeam IR radiometer is conducted to study the scale integration problem. A good agreement within less than 100 m relies on spatial uniformity and an optically thick layer. In the presence of holes, a discrepancy is observed. This is illustrated in figure 2, displaying as a function of time (1) the lidar signals; (2) the target temperature (either clouds or sea surface) retreived from a narrowbeam IR radiometer, 17 C is the sea surface temperature on that day; and (3) the visible flux, linked to cloud albedo, measured by a pyranometer. In preparation of ASTEX, down- and up-looking measurements where conducted on stratocumulus clouds over the Atlantic Ocean near Quimper in Brittany. Depending on the flight pattern orientation with respect to the wind, the top and bottom cloud morphologies are different. Preliminary results are given on cloud morphology, cloud top PDFs, optical porosity, fractional cloudiness, and comparison of lidar and radiometric measurements.

  5. Airborne lidar and radiometric observations of PBL- and low clouds

    NASA Technical Reports Server (NTRS)

    Flamant, P. H.; Valentin, R.; Pelon, J.

    1992-01-01

    lidar and narrowbeam IR radiometer is conducted to study the scale integration problem. A good agreement within less than 100 m relies on spatial uniformity and an optically thick layer. In the presence of holes, a discrepancy is observed. This is illustrated in figure 2, displaying as a function of time (1) the lidar signals; (2) the target temperature (either clouds or sea surface) retreived from a narrowbeam IR radiometer, 17 C is the sea surface temperature on that day; and (3) the visible flux, linked to cloud albedo, measured by a pyranometer. In preparation of ASTEX, down- and up-looking measurements where conducted on stratocumulus clouds over the Atlantic Ocean near Quimper in Brittany. Depending on the flight pattern orientation with respect to the wind, the top and bottom cloud morphologies are different. Preliminary results are given on cloud morphology, cloud top PDFs, optical porosity, fractional cloudiness, and comparison of lidar and radiometric measurements.

  6. Comparison of diverse methods for the correction of atmospheric effects on LANDSAT and SKYLAB images. [radiometric correction in Brazil

    NASA Technical Reports Server (NTRS)

    Parada, N. D. J. (Principal Investigator); Camara, G.; Dias, L. A. V.; Mascarenhas, N. D. D.; Desouza, R. C. M.; Pereira, A. E. C.

    1982-01-01

    Earth's atmosphere reduces a sensors ability in currently discriminating targets. Using radiometric correction to reduce the atmospheric effects may improve considerably the performance of an automatic image interpreter. Several methods for radiometric correction from the open literature are compared leading to the development of an atmospheric correction system.

  7. Aerial radiometric and magnetic survey: Marysvale detail survey, Richfield National Topographic Map sheet, Utah. Volume II. Radiometric multi-variable stacked profile data. Final report

    SciTech Connect

    Not Available

    1982-01-01

    The results of the analyses of a systematic airborne gamma radiation and total magnetic survey for the area identified as Marysvale, located in southwestern Utah, is presented in Volumes I-IV of this report. The airborne data gathered is reduced by ground computer facilities to yield profile plots of the equivalent uranium, thorium and potassium gamma radiation intensities, the ratios of these intensities, the total gamma radiation counting rate and the earth's residual magnetic field intensity. Profile plots of the aircraft's altitude above the earth's surface, the ambient temperature and pressure, and the magnetic field data measured by a base station magnetometer is presented also. An evaluation of the distribution of the radiometric data in terms of its established geochemical map units, which were derived via geochemical analysis methods, for the entire survey area has been prepared and is included. The determination of the geochemical units presented has been established principally from the analysis of the radiometric and magnetic contour maps and, more importantly, the multi-variate analysis map. A general description of the area, including descriptions of the various geologic and geochemical units, is included within the text. Volume II contains the 10-variable radiometric stacked profile data for the entire survey area.

  8. MARC: A Thought Experiment in the Morality of Automated Marking of English

    ERIC Educational Resources Information Center

    Elliott, Victoria

    2014-01-01

    Automated essay scoring programs are becoming more common and more technically advanced. They provoke strong reactions from both their advocates and their detractors. Arguments tend to fall into two categories: technical and principled. This paper argues that since technical difficulties will be overcome with time, the debate ought to be held in…

  9. MARC: A Thought Experiment in the Morality of Automated Marking of English

    ERIC Educational Resources Information Center

    Elliott, Victoria

    2014-01-01

    Automated essay scoring programs are becoming more common and more technically advanced. They provoke strong reactions from both their advocates and their detractors. Arguments tend to fall into two categories: technical and principled. This paper argues that since technical difficulties will be overcome with time, the debate ought to be held in…

  10. Workflow automation architecture standard

    SciTech Connect

    Moshofsky, R.P.; Rohen, W.T.

    1994-11-14

    This document presents an architectural standard for application of workflow automation technology. The standard includes a functional architecture, process for developing an automated workflow system for a work group, functional and collateral specifications for workflow automation, and results of a proof of concept prototype.

  11. Improving automation standards via semantic modelling: Application to ISA88.

    PubMed

    Dombayci, Canan; Farreres, Javier; Rodríguez, Horacio; Espuña, Antonio; Graells, Moisès

    2017-03-01

    Standardization is essential for automation. Extensibility, scalability, and reusability are important features for automation software that rely in the efficient modelling of the addressed systems. The work presented here is from the ongoing development of a methodology for semi-automatic ontology construction methodology from technical documents. The main aim of this work is to systematically check the consistency of technical documents and support the improvement of technical document consistency. The formalization of conceptual models and the subsequent writing of technical standards are simultaneously analyzed, and guidelines proposed for application to future technical standards. Three paradigms are discussed for the development of domain ontologies from technical documents, starting from the current state of the art, continuing with the intermediate method presented and used in this paper, and ending with the suggested paradigm for the future. The ISA88 Standard is taken as a representative case study. Linguistic techniques from the semi-automatic ontology construction methodology is applied to the ISA88 Standard and different modelling and standardization aspects that are worth sharing with the automation community is addressed. This study discusses different paradigms for developing and sharing conceptual models for the subsequent development of automation software, along with presenting the systematic consistency checking method.

  12. Automation in Clinical Microbiology

    PubMed Central

    Ledeboer, Nathan A.

    2013-01-01

    Historically, the trend toward automation in clinical pathology laboratories has largely bypassed the clinical microbiology laboratory. In this article, we review the historical impediments to automation in the microbiology laboratory and offer insight into the reasons why we believe that we are on the cusp of a dramatic change that will sweep a wave of automation into clinical microbiology laboratories. We review the currently available specimen-processing instruments as well as the total laboratory automation solutions. Lastly, we outline the types of studies that will need to be performed to fully assess the benefits of automation in microbiology laboratories. PMID:23515547

  13. Automation of industrial bioprocesses.

    PubMed

    Beyeler, W; DaPra, E; Schneider, K

    2000-01-01

    The dramatic development of new electronic devices within the last 25 years has had a substantial influence on the control and automation of industrial bioprocesses. Within this short period of time the method of controlling industrial bioprocesses has changed completely. In this paper, the authors will use a practical approach focusing on the industrial applications of automation systems. From the early attempts to use computers for the automation of biotechnological processes up to the modern process automation systems some milestones are highlighted. Special attention is given to the influence of Standards and Guidelines on the development of automation systems.

  14. Shoe-String Automation

    SciTech Connect

    Duncan, M.L.

    2001-07-30

    Faced with a downsizing organization, serious budget reductions and retirement of key metrology personnel, maintaining capabilities to provide necessary services to our customers was becoming increasingly difficult. It appeared that the only solution was to automate some of our more personnel-intensive processes; however, it was crucial that the most personnel-intensive candidate process be automated, at the lowest price possible and with the lowest risk of failure. This discussion relates factors in the selection of the Standard Leak Calibration System for automation, the methods of automation used to provide the lowest-cost solution and the benefits realized as a result of the automation.

  15. Application of multispectral LiDAR to automated virtual outcrop geology

    NASA Astrophysics Data System (ADS)

    Hartzell, Preston; Glennie, Craig; Biber, Kivanc; Khan, Shuhab

    2014-02-01

    Terrestrial laser scanning (TLS) is a valuable tool for creating virtual 3D models of geological outcrops to enable enhanced modeling and analysis of geologic strata. Application of TLS data is typically limited to the geometric point cloud that is used to create the 3D structure of the outcrop model. Digital photography can then be draped onto the 3D model, allowing visual identification and manual spatial delineation of different rock layers. Automation of the rock type identification and delineation is desirable, and recent work has investigated the use of terrestrial hyperspectral photography for this purpose. However, passive photography, whether visible or hyperspectral, presents several complexities, including accurate spatial registration with the TLS point cloud data, reliance on sunlight for illumination, and radiometric calibration to properly extract spectral signatures of the different rock types. As an active remote sensing method, a radiometrically calibrated TLS system offers the potential to directly provide spectral information for each recorded 3D point, independent of solar illumination. Therefore, the practical application of three radiometrically calibrated TLS systems with differing laser wavelengths, thereby achieving a multispectral dataset in conjunction with 3D point cloud data, is investigated using commercially available hardware and software. The radiometric calibration of the TLS intensity values is investigated and the classification performance of the multispectral TLS intensity and calibrated reflectance datasets evaluated and compared to classification performed with passive visible wavelength imagery. Results indicate that rock types can be successfully identified with radiometrically calibrated multispectral TLS data, with enhanced classification performance when fused with passive visible imagery.

  16. Automation of Hubble Space Telescope Mission Operations

    NASA Technical Reports Server (NTRS)

    Burley, Richard; Goulet, Gregory; Slater, Mark; Huey, William; Bassford, Lynn; Dunham, Larry

    2012-01-01

    On June 13, 2011, after more than 21 years, 115 thousand orbits, and nearly 1 million exposures taken, the operation of the Hubble Space Telescope successfully transitioned from 24x7x365 staffing to 815 staffing. This required the automation of routine mission operations including telemetry and forward link acquisition, data dumping and solid-state recorder management, stored command loading, and health and safety monitoring of both the observatory and the HST Ground System. These changes were driven by budget reductions, and required ground system and onboard spacecraft enhancements across the entire operations spectrum, from planning and scheduling systems to payload flight software. Changes in personnel and staffing were required in order to adapt to the new roles and responsibilities required in the new automated operations era. This paper will provide a high level overview of the obstacles to automating nominal HST mission operations, both technical and cultural, and how those obstacles were overcome.

  17. Modern trends in technical crystallization

    NASA Astrophysics Data System (ADS)

    Matz, G.

    1980-04-01

    Interesting and significant developments have occurred in the last decade in both crystallization equipment and in the theory of crystallization process. In the field of technical crystallization new crystallizers have been developed and computer modelling has become important in scaling up and in the achievement of increased performance. The DP-Kristaller developed by Escher-Wyss-Tsukishima, the Brodie purifier, the sieve tray column having dancing balls, the automated multiple crystallization process due to Mützenberg and Saxer and the double belt cooler, all of which represent technical developments, are described in the first section. The second part of the paper reviews computer modelling of the fluidized bed crystallizer, chemical precipitation, flaking and prilling. Finally, there is a brief discussion of the impact of technical crystallization processes on environmental protection.

  18. Human-system Interfaces to Automatic Systems: Review Guidance and Technical Basis

    SciTech Connect

    OHara, J.M.; Higgins, J.C.

    2010-01-31

    Automation has become ubiquitous in modern complex systems and commercial nuclear power plants are no exception. Beyond the control of plant functions and systems, automation is applied to a wide range of additional functions including monitoring and detection, situation assessment, response planning, response implementation, and interface management. Automation has become a 'team player' supporting plant personnel in nearly all aspects of plant operation. In light of the increasing use and importance of automation in new and future plants, guidance is needed to enable the NRC staff to conduct safety reviews of the human factors engineering (HFE) aspects of modern automation. The objective of the research described in this report was to develop guidance for reviewing the operator's interface with automation. We first developed a characterization of the important HFE aspects of automation based on how it is implemented in current systems. The characterization included five dimensions: Level of automation, function of automation, modes of automation, flexibility of allocation, and reliability of automation. Next, we reviewed literature pertaining to the effects of these aspects of automation on human performance and the design of human-system interfaces (HSIs) for automation. Then, we used the technical basis established by the literature to develop design review guidance. The guidance is divided into the following seven topics: Automation displays, interaction and control, automation modes, automation levels, adaptive automation, error tolerance and failure management, and HSI integration. In addition, we identified insights into the automaton design process, operator training, and operations.

  19. Establishing metrological traceability for radiometric calibration of earth observation sensor in Malaysia

    NASA Astrophysics Data System (ADS)

    Ng, S. W.; Zulkifli, A.

    2016-10-01

    The space borne earth observation (EO) sensor provides a continuous large spatial coverage over the earth at relatively low cost (cost-effective) and can be practically accessible worldwide. The daily synoptic view offered by instrument in earth orbit is tremendously useful in various applications, particularly long term global monitoring that needs multi-disciplinary, multi-temporal and multi-sensor data. Due to the indirect measurement nature of the EO sensor, calibration and validation (cal/val) are essentially required to establish the linkage between the acquired raw data and the actual target of interest. Ultimately, EO sensor provider must strive to deliver “the right information, at the right time, to the right people”. This paper is authored with the main aim to report the process of establishing metrological traceability for radiometric calibration of EO sensor at Optical Calibration Laboratory (OCL), National Space Agency of Malaysia (ANGKASA). The paper is structured into six sections. The first section introduces the context of EO and background of radiometric calibration. The next section discusses the requirements for metrological traceability in radiometric calibration while the following third section outlines ANGKASA efforts in setting up the metrological traceability laboratory in radiometric calibration. Meanwhile, the uncertainty estimation results is reported in the fourth section and the fifth section explains some of the continuous efforts made in order to improve the current metrological traceability set up. Lastly, the summary of this paper is provided in the last section.

  20. Investigation of Pre- and Post-Flight Radiometric Calibration Uncertainties from Surface Based Measurements

    SciTech Connect

    Heath, D.F.; Wei, Z.Y.; Ahman, Z.

    1997-06-01

    A new technique has been developed for inferring column ozone amounts and aerosol optical depths from zenith sky observations. A new radiometric calibration technique for large aperture remote sensing instruments observing the earth through space has been validated which subsequently increased the accuracy of remote sensing measurements of ozone and vertical profiles using measurements of back-scattered ultraviolet solar radiation.

  1. Radiometric flight results from the HyperSpectral Imager for Climate Science (HySICS)

    NASA Astrophysics Data System (ADS)

    Kopp, Greg; Smith, Paul; Belting, Chris; Castleman, Zach; Drake, Ginger; Espejo, Joey; Heuerman, Karl; Lanzi, James; Stuchlik, David

    2017-04-01

    Long-term monitoring of the Earth-reflected solar spectrum is necessary for discerning and attributing changes in climate. High radiometric accuracy enables such monitoring over decadal timescales with non-overlapping instruments, and high precision enables trend detection on shorter timescales. The HyperSpectral Imager for Climate Science (HySICS) is a visible and near-infrared spatial/spectral imaging spectrometer intended to ultimately achieve ˜ 0.2 % radiometric accuracies of Earth scenes from space, providing an order-of-magnitude improvement over existing space-based imagers. On-orbit calibrations from measurements of spectral solar irradiances acquired by direct views of the Sun enable radiometric calibrations with superior long-term stability than is currently possible with any manmade spaceflight light source or detector. Solar and lunar observations enable in-flight focal-plane array (FPA) flat-fielding and other instrument calibrations. The HySICS has demonstrated this solar cross-calibration technique for future spaceflight instrumentation via two high-altitude balloon flights. The second of these two flights acquired high-radiometric-accuracy measurements of the ground, clouds, the Earth's limb, and the Moon. Those results and the details of the uncertainty analyses of those flight data are described.

  2. Radiometric ages of brachyuran crabs from the Galapagos spreading-center hydrothermal ventfield

    SciTech Connect

    Bennett, J.T.; Turekian, K.K.

    1984-09-01

    The ages of four crab carapaces from the Galapagos spreading-center hydrothermal ventfield were determined radiometrically using members of the U and Th decay chains. One animal had an age of 0.1 years and therefore had undergone molting just before collection; the other three had last molted 3-4 years before collection.

  3. MODIS Cloud Optical Property Retrieval Uncertainties Derived from Pixel-Level VNIR/SWIR Radiometric Uncertainties

    NASA Technical Reports Server (NTRS)

    Platnick, S.; Wind, G.; Xiong, X.

    2011-01-01

    Moderate Resolution Imaging Spectroradiometer (MODIS) retrievals of optical thickness and effective particle radius for liquid water and ice phase clouds employ a well-known VNIR/ SWIR solar reflectance technique. For this type of algorithm, we evaluate the quantitative uncertainty in simultaneous retrievals of these two cloud parameters to pixel-level radiometric calibration estimates and other fundamental (and tractable) error sources.

  4. MODIS Cloud Optical Property Retrieval Uncertainties Derived from Pixel-Level Radiometric Error Estimates

    NASA Technical Reports Server (NTRS)

    Platnick, Steven; Wind, Galina; Xiong, Xiaoxiong

    2011-01-01

    MODIS retrievals of cloud optical thickness and effective particle radius employ a well-known VNIR/SWIR solar reflectance technique. For this type of algorithm, we evaluate the uncertainty in simultaneous retrievals of these two parameters to pixel-level (scene-dependent) radiometric error estimates as well as other tractable error sources.

  5. Aerial radiometric and magnetic reconnaissance survey of south-central Colorado Trinidad Quadrangle

    SciTech Connect

    Not Available

    1980-01-01

    The results of a high-sensitivity, aerial, gamma-ray spectrometer and magnetometer survey of the Trinidad Quadrangle, Colorado, are presented. Instrumentation and methods are described in Volume 1 of this final report. Statistical and geological analysis of radiometric data revealed 51 uranium anomalies worthy of field-checking as possible prospects.

  6. Landsat-8 Operational Land Imager (OLI) radiometric performance on-orbit

    USGS Publications Warehouse

    Morfitt, Ron; Barsi, Julia A.; Levy, Raviv; Markham, Brian L.; Micijevic, Esad; Ong, Lawrence; Scaramuzza, Pat; Vanderwerff, Kelly

    2015-01-01

    Expectations of the Operational Land Imager (OLI) radiometric performance onboard Landsat-8 have been met or exceeded. The calibration activities that occurred prior to launch provided calibration parameters that enabled ground processing to produce imagery that met most requirements when data were transmitted to the ground. Since launch, calibration updates have improved the image quality even more, so that all requirements are met. These updates range from detector gain coefficients to reduce striping and banding to alignment parameters to improve the geometric accuracy. This paper concentrates on the on-orbit radiometric performance of the OLI, excepting the radiometric calibration performance. Topics discussed in this paper include: signal-to-noise ratios that are an order of magnitude higher than previous Landsat missions; radiometric uniformity that shows little residual banding and striping, and continues to improve; a dynamic range that limits saturation to extremely high radiance levels; extremely stable detectors; slight nonlinearity that is corrected in ground processing; detectors that are stable and 100% operable; and few image artifacts.

  7. The Benefits of Office Automation: A Casebook

    DTIC Science & Technology

    1986-04-01

    3 Recommendations .................................. 33 5.3.1. Changes to Draft AF Regulation 4-4 ....... 33 5.3.2. OA Lessons Learned Program ................. 36...Acquisition Logistics Center (AFALC) establish an Air Force-wide Office Automation Lessons Learned Program . The objective of the program would be to...past technical and management decisions for application to their current or future projects. The OA Lessons Learned Program would take advantage of the

  8. Enhanced Automated Spiral Bevel Gear Inspection

    DTIC Science & Technology

    1992-03-01

    in excessive wear, scoring, or even tooth breakage. This is as true for spiral bevel gears as it is for spur and helical gears. The elemental...conformity inspection of tooth profiles that is commonly performed on spur and helical gears, however, is not practical for spiral bevel gears because the size...AD-A250 770 NASA AVSCOM Contractor Report 189125 Technical Report 91-C-048 Enhanced Automated Spiral Bevel Gear Inspection DTIC Harold K. Frint and

  9. Investigating the influence of radiometric calibration on tree species determination based on small footprint full-waveform airborne LiDAR

    NASA Astrophysics Data System (ADS)

    Mücke, W.; Briese, C.; Hollaus, M.; Pfeifer, N.; Wagner, W.

    2013-12-01

    Small footprint airborne LiDAR is a well-established measurement technique in forestry, where cost- and time efficient wide-area data acquisition of the vegetation structure is required. Gathering stand-based information about tree species composition is of particular interest for forestry applications. Modern LiDAR systems provide, next to the acquired 3D (i.e. geometric) information, also a quantification of the signal strength of each echo. In order to utilize this information for tree species determination independently from different overlapping LiDAR swaths, different LiDAR sensors or acquisition times, radiometric calibration is a necessity. This contribution summarises the theoretical background of radiometric LiDAR data calibration on the physical basis of the radar equation. Using LiDAR observations of reference targets with known reflectivity the so-called calibration constant is computed. It accounts for sensor specific parameters, as well as atmospheric attenuation of the laser signal. Hence the backscatter properties of the laser echoes can be determined and physical observables characterizing the reflectivity of the scanned surface can be estimated. A practical calibration workflow is demonstrated on the example of a single wavelength full-waveform LiDAR data set from a mixed woodland in Austria. Subsequently, an automated method for tree species determination that is based on the laser light scattering mechanisms in the forest canopy is applied on both (calibrated and un-calibrated) data sets. First, an edge-based segmentation approach is used to aggregate LiDAR echoes to segments representing single tree crowns. Second, metrics are computed for each tree crown describing radiometric and geometric features that are related to foliage composition. Third, these metrics are used in a knowledge-based fuzzy classification scheme for the determination of segments representing coniferous and deciduous trees. Influences of the radiometric calibration on the

  10. Automated construction of lightweight, simple, field-erected structures

    NASA Technical Reports Server (NTRS)

    Leonard, R. S.

    1980-01-01

    The feasibility of automation of construction processes which could result in mobile construction robots is examined. The construction of a large photovoltaic power plant with a peak power output of 100 MW is demonstrated. The reasons to automate the construction process, a conventional construction scenario as the reference for evaluation, and a list of potential cost benefits using robots are presented. The technical feasibility of using robots to construct SPS ground stations is addressed.

  11. Enhanced radiometric detection of Mycobacterium paratuberculosis by using filter-concentrated bovine fecal specimens

    SciTech Connect

    Collins, M.T.; Kenefick, K.B.; Sockett, D.C.; Lambrecht, R.S.; McDonald, J.; Jorgensen, J.B. )

    1990-11-01

    A commercial radiometric medium, BACTEC 12B, was modified by addition of mycobactin, egg yolk suspension, and antibiotics (vancomycin, amphotericin B, and nalidixic acid). Decontaminated bovine fecal specimens were filter concentrated by using 3-microns-pore-size, 13-mm-diameter polycarbonate filters, and the entire filter was placed into the radiometric broth. Comparison of the radiometric technique with conventional methods on 603 cattle from 9 Mycobacterium paratuberculosis-infected herds found that of 75 positive specimens, the radiometric technique detected 92% while conventional methods detected 60% (P less than 0.0005). Only 3.9% of radiometric cultures were contaminated. To measure the effect of filter concentration of specimens on the detection rate, 5 cattle with minimal and 5 with moderate ileum histopathology were sampled weekly for 3 weeks. M. paratuberculosis was detected in 33.3% of nonfiltered specimens and 76.7% of filtered specimens (P less than 0.005). Detection rates were directly correlated with the severity of disease, and the advantage of specimen concentration was greatest on fecal specimens from cattle with low-grade infections. Detection times were also correlated with infection severity: 13.4 +/- 5.9 days with smear-positive specimens, 27.9 +/- 8.7 days with feces from cows with typical subclinical infections, and 38.7 +/- 3.8 days with fecal specimens from cows with low-grade infections. Use of a cocktail of vancomycin, amphotericin B, and nalidixic acid for selective suppression of nonmycobacterial contaminants was better than the commercial product PANTA (Becton Dickinson Microbiologic Systems, Towson, Md.) only when specimens contained very low numbers of M. paratuberculosis.

  12. Dynamic noise corrected hyperspectral radiometric calibration in the SWIR range using a supercontinuum laser

    NASA Astrophysics Data System (ADS)

    Keresztes, Janos C.; Aernouts, Ben; Koshel, R. J.; Saeys, Wouter

    2015-09-01

    As line scanning short wave infrared (SWIR) hyperspectral imaging (HSI) is a growing field in the food industry, it is important to select efficient illumination designs to image contaminants with high contrast and low noise. Illumination systems can efficiently be compared and optimized through the use of ray tracing simulations. However, these simulations provide illumination patterns in absolute radiometric units while HSI systems typically provide relative measurements. To bridge this gap, a supercontinuum laser and monochromator setup was used in this study to calibrate a SWIR HSI imager in spectral radiometric units. For the radiometric calibration, an integrating sphere (IS) was illuminated with the monochromatic laser light, while both a high sensitivity photodiode and the hyperspectral camera were positioned at different ports of the IS to measure the diffuse light synchronously. For each spectral band, the radiance observed by the imager corresponding to a line was detected using image analysis, while the remainder of the image was used to sample the noise of the sensor. Laser power fluctuations were monitored using a power meter coupled with a thermal sensor, allowing for their correction. As these measurements were time consuming, while InGaAs based sensors are very sensitive to thermal drift, the dark current was sampled frequently to avoid noise time drifts. This approach allowed correcting for 6% of temporal noise fluctuations. A per-pixel linear radiometric model was fitted with an R2 of 0:94+/-0:3 and used to transfer the measured light distribution of a halogen spot with and without a diffuser into absolute radiometric units. This allowed comparing measurements with the results of ray tracing.

  13. Rapid radiometric methods to detect and differentiate Mycobacterium tuberculosis/M. bovis from other mycobacterial species

    SciTech Connect

    Siddiqi, S.H.; Hwangbo, C.C.; Silcox, V.; Good, R.C.; Snider, D.E. Jr.; Middlebrook, G.

    1984-10-01

    Rapid methods for the differentiation of Mycobacterium tuberculosis/M. bovis (TB complex) from other mycobacteria (MOTT bacilli) were developed and evaluated in a three-phase study. In the first phase, techniques for identification of Mycobacterium species were developed by using radiometric technology and BACTEC Middlebrook 7H12 liquid medium. Based on /sup 14/CO/sub 2/ evolution, characteristic growth patterns were established for 13 commonly encountered mycobacterial species. Mycobacteria belonging to the TB complex were differentiated from other mycobacteria by cellular morphology and rate of /sup 14/CO/sub 2/ evolution. For further differentiation, radiometric tests for niacin production and inhibition by Q-nitro-alpha-acetyl amino-beta-hydroxy-propiophenone (NAP) were developed. In the second phase, 100 coded specimens on Lowenstein-Jensen medium were identified as members of the TB complex, MOTT bacilli, bacteria other than mycobacteria, or ''no viable organisms'' within 3 to 12 (average 6.4) days of receipt from the Centers for Disease Control. Isolation and identification of mycobacteria from 20 simulated sputum specimens were carried out in phase III. Out of 20 sputum specimens, 16 contained culturable mycobacteria, and all of the positives were detected by the BACTEC method in an average of 7.3 days. The positive mycobacterial cultures were isolated and identified as TB complex or MOTT bacilli in an average of 12.8 days. The radiometric NAP test was found to be highly sensitive and specific for a rapid identification of TB complex, whereas the radiometric niacin test was found to have some inherent problems. Radiometric BACTEC and conventional methodologies were in complete agreement in Phase II as well as in Phase III.

  14. Refinements to MISR's radiometric calibration and implications for establishing a climate-quality aerosol observing system

    NASA Astrophysics Data System (ADS)

    Diner, David J.; Kahn, Ralph A.; Bruegge, Carol J.; Martonchik, John V.; Abdou, Wedad A.; Gaitley, Barbara J.; Helmlinger, Mark C.; Kalashnikova, Olga V.; Li, Wen-Hao

    2004-12-01

    A number of factors affect the accuracy of aerosol retrievals from satellite imaging radiometers, including algorithm assumptions, the quality of the associated cloud masks, the prescribed aerosol optical and microphysical models, and calibration uncertainties. In this paper, we highlight a concerted effort by the Terra Multi-angle Imaging SpectroRadiometer (MISR) team to evaluate the accuracy and stability of the instrument's radiometric calibration, with the twofold objective of (1) making improvements in the absolute and relative calibration where supported by multiple lines of evidence, and (2) evaluating the effect of those calibration refinements on aerosol retrievals. Aspects of the instrument's on-board calibrator design, including careful pre-flight handling of the Spectralon diffusers and the novel use of detector-based standards, have contributed to excellent long-term radiometric stability. In addition, multiple methodologies, including comparisons with other Terra sensors, in-flight and laboratory tests involving AirMISR (the airborne counterpart to MISR), lunar observations, camera-to-camera radiometric comparisons at specialized viewing geometries, and investigations using surface-based radiometer data over dark water sites have provided a detailed picture of radiometric performance at the low light levels typical of a large fraction of global aerosol observations. We examine the sensitivity of aerosol property retrievals to small band-to-band and camera-to-camera calibration adjustments, and demonstrate the importance of calibration in meeting climate-quality accuracy requirements. Because combining downward-looking (satellite-based) and upward-looking (surface-based) radiometers can constrain the optical properties of an aerosol column to a greater extent than possible from either vantage point by itself, achieving radiometric consistency, or "closure" between them is essential to establishing a long-term aerosol/climate observing system.

  15. Identifying Needed Technical Standards: The LITA TESLA Committee at Work.

    ERIC Educational Resources Information Center

    Carter, Ruth C.

    1984-01-01

    Efforts of the Technical Standards for Library Automation Committee (TESLA), a division-wide committee of the Library Information and Technology Association (LITA) of the American Library Association, are described. The current status of suggested technical standards and recommended action are detailed. Five sources are given. (Author/EJS)

  16. Identifying Needed Technical Standards: The LITA TESLA Committee at Work.

    ERIC Educational Resources Information Center

    Carter, Ruth C.

    1984-01-01

    Efforts of the Technical Standards for Library Automation Committee (TESLA), a division-wide committee of the Library Information and Technology Association (LITA) of the American Library Association, are described. The current status of suggested technical standards and recommended action are detailed. Five sources are given. (Author/EJS)

  17. Automated DNA Sequencing System

    SciTech Connect

    Armstrong, G.A.; Ekkebus, C.P.; Hauser, L.J.; Kress, R.L.; Mural, R.J.

    1999-04-25

    Oak Ridge National Laboratory (ORNL) is developing a core DNA sequencing facility to support biological research endeavors at ORNL and to conduct basic sequencing automation research. This facility is novel because its development is based on existing standard biology laboratory equipment; thus, the development process is of interest to the many small laboratories trying to use automation to control costs and increase throughput. Before automation, biology Laboratory personnel purified DNA, completed cycle sequencing, and prepared 96-well sample plates with commercially available hardware designed specifically for each step in the process. Following purification and thermal cycling, an automated sequencing machine was used for the sequencing. A technician handled all movement of the 96-well sample plates between machines. To automate the process, ORNL is adding a CRS Robotics A- 465 arm, ABI 377 sequencing machine, automated centrifuge, automated refrigerator, and possibly an automated SpeedVac. The entire system will be integrated with one central controller that will direct each machine and the robot. The goal of this system is to completely automate the sequencing procedure from bacterial cell samples through ready-to-be-sequenced DNA and ultimately to completed sequence. The system will be flexible and will accommodate different chemistries than existing automated sequencing lines. The system will be expanded in the future to include colony picking and/or actual sequencing. This discrete event, DNA sequencing system will demonstrate that smaller sequencing labs can achieve cost-effective the laboratory grow.

  18. Mesoscale, Radiometrically Referenced, Multi-Temporal Hyperspectral Data for Co2 Leak Detection by Locating Spatial Variation of Biophysically Relevant Parameters

    NASA Astrophysics Data System (ADS)

    McCann, Cooper Patrick

    Low-cost flight-based hyperspectral imaging systems have the potential to provide valuable information for ecosystem and environmental studies as well as aide in land management and land health monitoring. This thesis describes (1) a bootstrap method of producing mesoscale, radiometrically-referenced hyperspectral data using the Landsat surface reflectance (LaSRC) data product as a reference target, (2) biophysically relevant basis functions to model the reflectance spectra, (3) an unsupervised classification technique based on natural histogram splitting of these biophysically relevant parameters, and (4) local and multi-temporal anomaly detection. The bootstrap method extends standard processing techniques to remove uneven illumination conditions between flight passes, allowing the creation of radiometrically self-consistent data. Through selective spectral and spatial resampling, LaSRC data is used as a radiometric reference target. Advantages of the bootstrap method include the need for minimal site access, no ancillary instrumentation, and automated data processing. Data from a flight on 06/02/2016 is compared with concurrently collected ground based reflectance spectra as a means of validation achieving an average error of 2.74%. Fitting reflectance spectra using basis functions, based on biophysically relevant spectral features, allows both noise and data reductions while shifting information from spectral bands to biophysical features. Histogram splitting is used to determine a clustering based on natural splittings of these fit parameters. The Indian Pines reference data enabled comparisons of the efficacy of this technique to established techniques. The splitting technique is shown to be an improvement over the ISODATA clustering technique with an overall accuracy of 34.3/19.0% before merging and 40.9/39.2% after merging. This improvement is also seen as an improvement of kappa before/after merging of 24.8/30.5 for the histogram splitting technique

  19. HADES PC network: an automated data entry system

    SciTech Connect

    Hegemann, D.L.

    1986-09-12

    Mound's Health Physics section is faced with an increasing need to store and retrieve radiological data. This need has been addressed by the Health Physics Automated Data Entry System (HADES) which assumed a full production status on April 1, 1986. Mound's Technical Computer Support group implemented HADES in a series of phases which allowed high priority needs to be immediately supported. As a result of the system's personal computer-based structure, additional capabilities such as automated data acquisition were easily brought on-line. Since its inception in the first quarter of 1984, HADES has matured into a cost-efficient automated data acquisition system for Mound's Health Physics section.

  20. Machining automation: Doing it right the first time

    SciTech Connect

    Setter, D.L.

    1990-08-01

    The implementation of a machining automation program and of the Allied-Signal efforts to Do it Right the First Time'' is presented. The automation program is a Flexible Manufacturing System (FMS) for the machining and on-line inspection of a family of aluminum and stainless steel prismatic parts. The critical management and technical aspects found necessary to assure success in implementing large and risky automation programs are presented. The process being used is team based and has concentrated on involving the end users from the beginning.

  1. Automated ship image acquisition

    NASA Astrophysics Data System (ADS)

    Hammond, T. R.

    2008-04-01

    The experimental Automated Ship Image Acquisition System (ASIA) collects high-resolution ship photographs at a shore-based laboratory, with minimal human intervention. The system uses Automatic Identification System (AIS) data to direct a high-resolution SLR digital camera to ship targets and to identify the ships in the resulting photographs. The photo database is then searchable using the rich data fields from AIS, which include the name, type, call sign and various vessel identification numbers. The high-resolution images from ASIA are intended to provide information that can corroborate AIS reports (e.g., extract identification from the name on the hull) or provide information that has been omitted from the AIS reports (e.g., missing or incorrect hull dimensions, cargo, etc). Once assembled into a searchable image database, the images can be used for a wide variety of marine safety and security applications. This paper documents the author's experience with the practicality of composing photographs based on AIS reports alone, describing a number of ways in which this can go wrong, from errors in the AIS reports, to fixed and mobile obstructions and multiple ships in the shot. The frequency with which various errors occurred in automatically-composed photographs collected in Halifax harbour in winter time were determined by manual examination of the images. 45% of the images examined were considered of a quality sufficient to read identification markings, numbers and text off the entire ship. One of the main technical challenges for ASIA lies in automatically differentiating good and bad photographs, so that few bad ones would be shown to human users. Initial attempts at automatic photo rating showed 75% agreement with manual assessments.

  2. Approaches to automated protein crystal harvesting

    PubMed Central

    Deller, Marc C.; Rupp, Bernhard

    2014-01-01

    The harvesting of protein crystals is almost always a necessary step in the determination of a protein structure using X-ray crystallographic techniques. However, protein crystals are usually fragile and susceptible to damage during the harvesting process. For this reason, protein crystal harvesting is the single step that remains entirely dependent on skilled human intervention. Automation has been implemented in the majority of other stages of the structure-determination pipeline, including cloning, expression, purification, crystallization and data collection. The gap in automation between crystallization and data collection results in a bottleneck in throughput and presents unfortunate opportunities for crystal damage. Several automated protein crystal harvesting systems have been developed, including systems utilizing microcapillaries, microtools, microgrippers, acoustic droplet ejection and optical traps. However, these systems have yet to be commonly deployed in the majority of crystallography laboratories owing to a variety of technical and cost-related issues. Automation of protein crystal harvesting remains essential for harnessing the full benefits of fourth-generation synchrotrons, free-electron lasers and microfocus beamlines. Furthermore, automation of protein crystal harvesting offers several benefits when compared with traditional manual approaches, including the ability to harvest microcrystals, improved flash-cooling procedures and increased throughput. PMID:24637746

  3. Radiometric & other requirements for accreditation of PV testing laboratories

    SciTech Connect

    Zerlaut, G.A.

    1995-09-01

    It is intended that the requirements for calibration, traceability of calibration and statistical representation of calibration and test data represent additional requirement of the Laboratory Quality System developed in support of the photovoltaic module certification and labeling program. The elements of this program, which are listed in Chart 1 in the form of major program documentation, have been developed in a contract at Arizona State University under Subcontract from NREL. Documents PV-1 through PV-2, as well as technical issues and deliberations of the Criteria Development Committee (CDC), represent the Phase I results are presented in NREL Report TP-412-7680. Phase II of the program is currently underway and certain of the results of this work are the subject of this paper. Much of the material presented in this paper were developed by the author as Document PV-1. 1a. (Addendum to Document PV-1), which is currently out for review by the CDC. These requirements are intended to be employed by laboratories engaged in testing photovoltaic devices in support of the module certification program, and assessment bodies, and their assessors (or auditors), as additional criteria against which laboratories are examined for the purposes of initial and continuing accreditation.

  4. Radiometric age file for Alaska: A section in The United States Geological Survey in Alaska: Accomplishments during 1980

    USGS Publications Warehouse

    Shew, Nora; Wilson, Frederic H.

    1982-01-01

    The Alaska radiometric age file of the Branch of Alaskan Geology is a computer-based compilation of radiometric dates from the state of Alaska and the western parts of the Yukon Territory and British Columbia. More than 1800 age determinations from over 250 references have been entered in the file. References date back to 1958 and include both published and unpublished sources. The file is the outgrowth of an original radiometric age file compiled by Don Grybeck and students at the University of Alaska-Fairbanks (Turner and others, 1975).

  5. Management Planning for Workplace Automation.

    ERIC Educational Resources Information Center

    McDole, Thomas L.

    Several factors must be considered when implementing office automation. Included among these are whether or not to automate at all, the effects of automation on employees, requirements imposed by automation on the physical environment, effects of automation on the total organization, and effects on clientele. The reasons behind the success or…

  6. Laboratory Automation and Middleware.

    PubMed

    Riben, Michael

    2015-06-01

    The practice of surgical pathology is under constant pressure to deliver the highest quality of service, reduce errors, increase throughput, and decrease turnaround time while at the same time dealing with an aging workforce, increasing financial constraints, and economic uncertainty. Although not able to implement total laboratory automation, great progress continues to be made in workstation automation in all areas of the pathology laboratory. This report highlights the benefits and challenges of pathology automation, reviews middleware and its use to facilitate automation, and reviews the progress so far in the anatomic pathology laboratory.

  7. Complacency and Automation Bias in the Use of Imperfect Automation.

    PubMed

    Wickens, Christopher D; Clegg, Benjamin A; Vieane, Alex Z; Sebok, Angelia L

    2015-08-01

    We examine the effects of two different kinds of decision-aiding automation errors on human-automation interaction (HAI), occurring at the first failure following repeated exposure to correctly functioning automation. The two errors are incorrect advice, triggering the automation bias, and missing advice, reflecting complacency. Contrasts between analogous automation errors in alerting systems, rather than decision aiding, have revealed that alerting false alarms are more problematic to HAI than alerting misses are. Prior research in decision aiding, although contrasting the two aiding errors (incorrect vs. missing), has confounded error expectancy. Participants performed an environmental process control simulation with and without decision aiding. For those with the aid, automation dependence was created through several trials of perfect aiding performance, and an unexpected automation error was then imposed in which automation was either gone (one group) or wrong (a second group). A control group received no automation support. The correct aid supported faster and more accurate diagnosis and lower workload. The aid failure degraded all three variables, but "automation wrong" had a much greater effect on accuracy, reflecting the automation bias, than did "automation gone," reflecting the impact of complacency. Some complacency was manifested for automation gone, by a longer latency and more modest reduction in accuracy. Automation wrong, creating the automation bias, appears to be a more problematic form of automation error than automation gone, reflecting complacency. Decision-aiding automation should indicate its lower degree of confidence in uncertain environments to avoid the automation bias. © 2015, Human Factors and Ergonomics Society.

  8. Space station automation study. Volume 1: Executive summary. Autonomous systems and assembly

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The purpose of the Space Station Automation Study (SSAS) was to develop informed technical guidance for NASA personnel in the use of autonomy and autonomous systems to implement space station functions.

  9. Chlordane (Technical)

    Integrated Risk Information System (IRIS)

    Chlordane ( Technical ) ; CASRN 12789 - 03 - 6 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarc

  10. Technical Mathematics.

    ERIC Educational Resources Information Center

    Flannery, Carol A.

    This manuscript provides information and problems for teaching mathematics to vocational education students. Problems reflect applications of mathematical concepts to specific technical areas. The materials are organized into six chapters. Chapter 1 covers basic arithmetic, including fractions, decimals, ratio and proportions, percentages, and…

  11. Technical Mathematics.

    ERIC Educational Resources Information Center

    Flannery, Carol A.

    This manuscript provides information and problems for teaching mathematics to vocational education students. Problems reflect applications of mathematical concepts to specific technical areas. The materials are organized into six chapters. Chapter 1 covers basic arithmetic, including fractions, decimals, ratio and proportions, percentages, and…

  12. Advancing automation and robotics technology for the Space Station and for the US economy, volume 2

    NASA Technical Reports Server (NTRS)

    1985-01-01

    In response to Public Law 98-371, dated July 18, 1984, the NASA Advanced Technology Advisory Committee has studied automation and robotics for use in the Space Station. The Technical Report, Volume 2, provides background information on automation and robotics technologies and their potential and documents: the relevant aspects of Space Station design; representative examples of automation and robotics; applications; the state of the technology and advances needed; and considerations for technology transfer to U.S. industry and for space commercialization.

  13. Matters concerned with designing distributed systems for automated control of electrical equipment at power stations

    NASA Astrophysics Data System (ADS)

    Gorozhankin, P. A.; Krasnova, M. E.

    2011-10-01

    Matters concerned with developing the working designs of systems for automated control of electrical equipment are discussed. Basic technical requirements for computerized automation facilities are formulated from the viewpoint of ensuring the required scope of functions and fault tolerance, and proposals for the layout and placement of these facilities are suggested. A special section devoted to protection of automated process control systems from computer viruses is given.

  14. BacT/Alert: an automated colorimetric microbial detection system.

    PubMed Central

    Thorpe, T C; Wilson, M L; Turner, J E; DiGuiseppi, J L; Willert, M; Mirrett, S; Reller, L B

    1990-01-01

    BacT/Alert (Organon Teknika Corp., Durham, N.C.) is an automated microbial detection system based on the colorimetric detection of CO2 produced by growing microorganisms. Results of an evaluation of the media, sensor, detection system, and detection algorithm indicate that the system reliably grows and detects a wide variety of bacteria and fungi. Results of a limited pilot clinical trial with a prototype research instrument indicate that the system is comparable to the radiometric BACTEC 460 system in its ability to grow and detect microorganisms in blood. On the basis of these initial findings, large-scale clinical trials comparing BacT/Alert with other commercial microbial detection systems appear warranted. PMID:2116451

  15. Revised Landsat-5 TM radiometric calibration procedures and postcalibration dynamic ranges

    USGS Publications Warehouse

    Chander, G.; Markham, B.

    2003-01-01

    Effective May 5, 2003, Landsat-5 (L5) Thematic Mapper (TM) data processed and distributed by the U.S. Geological Survey (USGS) Earth Resources Observation System (EROS) Data Center (EDC) will be radiometrically calibrated using a new procedure and revised calibration parameters. This change will improve absolute calibration accuracy, consistency over time, and consistency with Landsat-7 (L7) Enhanced Thematic Mapper Plus (ETM+) data. Users will need to use new parameters to convert the calibrated data products to radiance. The new procedure for the reflective bands (1-5,7) is based on a lifetime radiometric calibration curve for the instrument derived from the instrument's internal calibrator, cross-calibration with the ETM+, and vicarious measurements. The thermal band will continue to be calibrated using the internal calibrator. Further updates to improve the relative detector-to-detector calibration and thermal band calibration are being investigated, as is the calibration of the Landsat-4 (L4) TM.

  16. Radiometric responsivity determination for Feature Identification and Location Experiment (FILE) flown on space shuttle mission

    NASA Technical Reports Server (NTRS)

    Wilson, R. G.; Davis, R. E.; Wright, R. E., Jr.; Sivertson, W. E., Jr.; Bullock, G. F.

    1986-01-01

    A procedure was developed to obtain the radiometric (radiance) responsivity of the Feature Identification and Local Experiment (FILE) instrument in preparation for its flight on Space Shuttle Mission 41-G (November 1984). This instrument was designed to obtain Earth feature radiance data in spectral bands centered at 0.65 and 0.85 microns, along with corroborative color and color-infrared photographs, and to collect data to evaluate a technique for in-orbit autonomous classification of the Earth's primary features. The calibration process incorporated both solar radiance measurements and radiative transfer model predictions in estimating expected radiance inputs to the FILE on the Shuttle. The measured data are compared with the model predictions, and the differences observed are discussed. Application of the calibration procedure to the FILE over an 18-month period indicated a constant responsivity characteristic. This report documents the calibration procedure and the associated radiometric measurements and predictions that were part of the instrument preparation for flight.

  17. Extreme Ultraviolet Variability Experiment (EVE) Multiple EUV Grating Spectrographs (MEGS): Radiometric Calibrations and Results

    NASA Technical Reports Server (NTRS)

    Hock, R. A.; Woods, T. N.; Crotser, D.; Eparvier, F. G.; Woodraska, D. L.; Chamberlin, P. C.; Woods, E. C.

    2010-01-01

    The NASA Solar Dynamics Observatory (SDO), scheduled for launch in early 2010, incorporates a suite of instruments including the Extreme Ultraviolet Variability Experiment (EVE). EVE has multiple instruments including the Multiple Extreme ultraviolet Grating Spectrographs (MEGS) A, B, and P instruments, the Solar Aspect Monitor (SAM), and the Extreme ultraviolet SpectroPhotometer (ESP). The radiometric calibration of EVE, necessary to convert the instrument counts to physical units, was performed at the National Institute of Standards and Technology (NIST) Synchrotron Ultraviolet Radiation Facility (SURF III) located in Gaithersburg, Maryland. This paper presents the results and derived accuracy of this radiometric calibration for the MEGS A, B, P, and SAM instruments, while the calibration of the ESP instrument is addressed by Didkovsky et al. . In addition, solar measurements that were taken on 14 April 2008, during the NASA 36.240 sounding-rocket flight, are shown for the prototype EVE instruments.

  18. A radiometric method for predicting effectiveness of chemotherapeutic agents in murine leprosy.

    PubMed

    Camargo, E E; Larson, S M; Tepper, B S; Wagner, H N

    1975-01-01

    A simple radiometric method has been developed for evaluating the effect of drugs on the metabolism of M. lepraemurium. The method is based on the measurement of the 14CO2 produced through bacterial metabolism of acetate-U-14C. Seventeen drugs were tested: bacitracin, cephaloridine, chloramphenicol, cycloserine, dactinomycin, DDS, ethionamide, INH, kanamycin, methenamine mandelate, nitrofurantoin, oxacillin, polymyxin B, rifampicin, streptomycin, sulfadimethoxine and vancomycin. The drugs which caused most marked inhibition were chloramphenicol, INH, ethionamide and nitrofurantoin in order of increasing effectiveness. The radiometric study which is completed in 15 days permits direct study of the drug effect on the metabolism of M. lepraemurium and a more rapid screening of antileprosy drugs than has previously been possible. Currently, these observations are being extended to studies of the structure-activity relationships of antileprosy drugs and the metabolism and drug susceptibility of M. leprae in vitro.

  19. Mississippi exploration field trials using microbial, radiometrics, free soil gas, and other techniques

    SciTech Connect

    Moody, J.S.; Brown, L.R.; Thieling, S.C.

    1995-12-31

    The Mississippi Office of Geology has conducted field trials using the surface exploration techniques of geomicrobial, radiometrics, and free soil gas. The objective of these trials is to determine if Mississippi oil and gas fields have surface hydrocarbon expression resulting from vertical microseepage migration. Six fields have been surveyed ranging in depth from 3,330 ft to 18,500 ft. The fields differ in trapping styles and hydrocarbon type. The results so far indicate that these fields do have a surface expression and that geomicrobial analysis as well as radiometrics and free soil gas can detect hydrocarbon microseepage from pressurized reservoirs. All three exploration techniques located the reservoirs independent of depth, hydrocarbon type, or trapping style.

  20. Real-Time EDL Navigation Performance Using Spacecraft to Spacecraft Radiometric Data

    NASA Technical Reports Server (NTRS)

    Burkhart, P. Daniel; Ely, Todd; Duncan, Courtney; Lightsey, Glenn; Campbell, Todd; Mogensen, Andy

    2006-01-01

    A two-year task sponsored by NASA's Mars Technology Program's Advanced Entry, Descent and Landing (EDL) work area includes investigation of improvements to EDL navigation by processing spacecraft-to-spacecraft radiometric data. Spacecraft-to- spacecraft navigation will take advantage of the UHF link between two spacecraft (i.e. to an orbiter from an approaching lander for EDL telemetry relay) to build radiometric data, specifically the velocity between the two spacecraft along the radio beam, that are processed to determine position and velocity in real time. The improved onboard state knowledge provided by spacecraft-to-spacecraft navigation will improve the performance of entry guidance by providing a more accurate state estimate and ultimately reduce the landed position error. Work on the final year of this task is reported here.

  1. Improved ground calibration results from Southwest Research Institute Ultraviolet Radiometric Calibration Facility (UV-RCF)

    NASA Astrophysics Data System (ADS)

    Davis, Michael W.; Greathouse, Thomas K.; Gladstone, G. Randall; Retherford, Kurt D.; Slater, David C.; Stern, S. Alan; Versteeg, Maarten H.

    2014-07-01

    Four compact planetary ultraviolet spectrographs have been built by Southwest Research Institute and successfully operated on different planetary missions. These spectrographs underwent a series of ground radiometric calibrations before delivery to their respective spacecraft. In three of the four cases, the in-flight measured sensitivity was approximately 50% lower than the ground measurement. Recent tests in the Southwest Research Institute Ultraviolet Radiometric Calibration Facility (UV-RCF) explain the discrepancy between ground and flight results. Revised ground calibration results are presented for the Rosetta-Alice, New Horizons-Alice, the Lunar Reconnaissance Orbiter Lyman- Alpha Mapping Project, and Juno-Ultraviolet Spectrograph (UVS) and are then compared to the original ground and flight calibrations. The improved understanding of the calibration system reported here will result in improved ground calibration of the upcoming Jupiter Icy Moons Explorer (JUICE)-UVS.

  2. Real-Time EDL Navigation Performance Using Spacecraft to Spacecraft Radiometric Data

    NASA Technical Reports Server (NTRS)

    Burkhart, P. Daniel; Ely, Todd; Duncan, Courtney; Lightsey, Glenn; Campbell, Todd; Mogensen, Andy

    2006-01-01

    A two-year task sponsored by NASA's Mars Technology Program's Advanced Entry, Descent and Landing (EDL) work area includes investigation of improvements to EDL navigation by processing spacecraft-to-spacecraft radiometric data. Spacecraft-to- spacecraft navigation will take advantage of the UHF link between two spacecraft (i.e. to an orbiter from an approaching lander for EDL telemetry relay) to build radiometric data, specifically the velocity between the two spacecraft along the radio beam, that are processed to determine position and velocity in real time. The improved onboard state knowledge provided by spacecraft-to-spacecraft navigation will improve the performance of entry guidance by providing a more accurate state estimate and ultimately reduce the landed position error. Work on the final year of this task is reported here.

  3. Determination of in vitro susceptibility of Mycobacterium tuberculosis to cephalosporins by radiometric and conventional methods

    SciTech Connect

    Heifets, L.B.; Iseman, M.D.; Cook, J.L.; Lindholm-Levy, P.J.; Drupa, I.

    1985-01-01

    Among eight cephalosporins and cephamycins tested in preliminary in vitro screening against Mycobacterium tuberculosis, the most promising for further study was found to be ceforanide, followed by ceftizoxime, cephapirin, and cefotaxime. Moxalactam, cefoxitin, cefamandole, and cephalothin were found to be not active enough against M. tuberculosis to be considered for further in vitro studies. The antibacterial activity of various ceforanide concentrations was investigated by three methods: (i) the dynamics of radiometric readings (growth index) in 7H12 broth; (ii) the number of CFU in the same medium; and (iii) the proportion method on 7H11 agar plates. There was a good correlation among the results obtained with these methods. The MIC for most strains ranged from 6.0 to 25.0 micrograms/ml. The BACTEC radiometric method is a reliable, rapid, and convenient method for preliminary screening and determination of the level of antibacterial activity of drugs not commonly used against M. tuberculosis.

  4. Radiometric and dosimetric characteristics of HgI/sub 2/ detectors

    SciTech Connect

    Zaletin, V.M.; Krivozubov, O.V.; Torlin, M.A.; Fomin, V.I.

    1988-04-01

    The characteristics of HgI/sub 2/ detectors in x-ray and gamma detection in applications to radiometric and dosimetric monitoring and as portable instruments for such purposes was considered. Blocks with mosaic and sandwich structures were prepared and tested against each other and, for comparative purposes, against CdTe detectors for relative sensitivities at various gamma-quanta energies. Sensitivity dependencies on gamma radiation energy were plotted for the detector materials and structures as were current dependencies on the dose rate of x rays. Results indicated that the mercury iodide detectors could be used in radiometric and dosimetric measurements at gamma quantum energies up to and in excess of 1000 KeV.

  5. Radiometric calibration and atmospheric correction of satellite and aircraft data for FIFE

    NASA Technical Reports Server (NTRS)

    Goetz, Scott J.; Markham, Brian L.; Newcomer, Jeffery A.

    1992-01-01

    The satellite and aircraft radiometric calibration and atmospheric correction work carried out as part of the first International Satellite Land Surface Climatology Project (ISLSCP) Field Experiment (FIFE) are summarized. A large volume (120 Gbytes) of radiometric data were acquired and derived from a number of different instruments on a variety of platforms. The same basic procedure was applied to each instrument: derive the most recent calibration coefficients for converting sensor counts to reflective spectral radiances; correct the radiances for earth-sun distance variations and incident solar spectral irradiance within the bandpass of each respective instrument channel at the top of the atmosphere; characterize the atmosphere for aerosols and absorbing gases; and derive apparent surface reflectance by correcting the exoatmospheric values for atmospheric attenuation. The same basic approach was used for surface temperature derivation. The results of this processing were verified by surface measurements, and corroborated by sensor intercomparisons.

  6. Airborne Visible/Infrared Imaging Spectrometer (AVIRIS): Inflight radiometric calibration and the determination of surface reflectance

    NASA Technical Reports Server (NTRS)

    Conel, J. E.; Vane, G.; Green, R. O.; Alley, R. E.; Carere, V.; Gabell, A.; Bruegge, C. J.

    1988-01-01

    The inflight radiometric performance of AVIRIS is presented together with a comparison of methods of recovering surface spectral reflectance from the data. Performance is evaluated by comparing radiance predicted from AVIRIS with radiance generated from the LOWIRAN 6 atmospheric model and measured surface reflectance. Comparisons show apparent agreement to within a few percent between 1800 and 2450 nm. Between 600 and 1800 nm the response of AVIRIS is systematically low by as much as 70 percent, and between 400 and 600 nm it is higher than expected. These problems are traced to thermal distortions of the instrument, and to detachment during flight of optical fibers connecting foreoptics to two of four spectrometers in the instrument. Of three methods studied, an empirical one involving calibration curves constructed from field reflectance measurements returns accurate predictions of the surface reflectance independent of the actual radiometric significance of the flight data.

  7. Recovery and susceptibility testing of Mycobacterium tuberculosis from extrapulmonary specimens by the BACTEC radiometric method.

    PubMed Central

    Fadda, G; Roe, S L

    1984-01-01

    This study was carried out to evaluate the sensitivity and rapidity of the BACTEC radiometric techniques for isolation and susceptibility testing of mycobacteria from extrapulmonary specimens. Concentrated specimens of urine, pleural fluid, and blood as well as other extrapulmonary specimens were processed for the recovery of mycobacteria and for drug susceptibility testing, employing conventional and BACTEC radiometric methods. Out of 483 specimens processed, 20 were found to be positive for Mycobacterium tuberculosis on the conventional Lowenstein -Jensen medium, and 19 were found to be positive in the BACTEC 7H12 medium. Average recovery times were 22.5 days for the conventional method and 10.9 days for the BACTEC method. When isolated cultures were tested for susceptibility to streptomycin, isoniazid, rifampin, and ethambutol, results were reported at an average time of 22 and 5.4 days for the conventional and BACTEC methods, respectively, with good correlation. PMID:6429193

  8. Errors in radiometric remote sensing of sea-surface temperature and salinity

    NASA Technical Reports Server (NTRS)

    Britt, C. L., Jr.

    1984-01-01

    Techniques for remote measurement of sea-surface physical temperature and salinity using radiometric measurements from aircraft or satellite are reviewed. Studies have been conducted to determine the sensitivity of the errors in surface temperature and salinity to errors in the measured brightness temperatures using combinations of UHF, L, S, and C-band measurements. These investigations were made using values of conductivity, static dielectric constant, and relaxation time derived from the regression equations of Klein and Swift (1977). Results of the error sensitivity study are presented in the form of error contour plots which permit the calculation of errors in the estimation of the physical parameters for given errors in the raw radiometric measurements.

  9. Determination of in vitro susceptibility of Mycobacterium tuberculosis to cephalosporins by radiometric and conventional methods.

    PubMed Central

    Heifets, L B; Iseman, M D; Cook, J L; Lindholm-Levy, P J; Drupa, I

    1985-01-01

    Among eight cephalosporins and cephamycins tested in preliminary in vitro screening against Mycobacterium tuberculosis, the most promising for further study was found to be ceforanide, followed by ceftizoxime, cephapirin, and cefotaxime. Moxalactam, cefoxitin, cefamandole, and cephalothin were found to be not active enough against M. tuberculosis to be considered for further in vitro studies. The antibacterial activity of various ceforanide concentrations was investigated by three methods: (i) the dynamics of radiometric readings (growth index) in 7H12 broth; (ii) the number of CFU in the same medium; and (iii) the proportion method on 7H11 agar plates. There was a good correlation among the results obtained with these methods. The MIC for most strains ranged from 6.0 to 25.0 micrograms/ml. The BACTEC radiometric method is a reliable, rapid, and convenient method for preliminary screening and determination of the level of antibacterial activity of drugs not commonly used against M. tuberculosis. PMID:3920957

  10. A liquid-helium-cooled absolute reference cold load for long-wavelength radiometric calibration

    NASA Technical Reports Server (NTRS)

    Bensadoun, Marc; Witebsky, Chris; Smoot, George; De Amici, Giovanni; Kogut, AL; Levin, Steve

    1992-01-01

    Design, radiometric and thermal performance, and operation of a large diameter (78 cm) liquid-helium-cooled blackbody absolute reference cold load (CL) for the calibration of microwave radiometers is described. CL provides an absolute calibration near the liquid-helium (LHe) boiling point, with total uncertainty in the radiometric temperature of less than 30 mK over the 2.5-23 cm wavelength operating range. CL was used at several wavelengths at the South Pole, Antarctica and the White Mountain Research Center, California. Results show that, for the instruments operated at 20-, 12-, 7.9-, and 4.0 cm wavelength at the South Pole, the total corrections to the LHe boiling-point temperature (about 3.8 K) were 48 +/-23, 18 +/-10, 10 +/-18, and 15 +/-mK.

  11. Direct antimicrobial drug susceptibility testing of Mycobacterium tuberculosis by the radiometric method

    SciTech Connect

    Libonati, J.P.; Stager, C.E.; Davis, J.R.; Siddiqi, S.H.

    1988-05-01

    Direct-drug-susceptibility tests were performed on clinical specimens positive for acid-fast bacilli by either Ziehl-Neelsen or fluorochrome staining. The results of conventional agar dilution and a modified radiometric (BACTEC) method were compared. A total of 580 smear-positive specimens were tested by the BACTEC method at three separate sites. Three hundred and seventy-seven of these were culture positive for M. tuberculosis, and 343 (91%) yielded acceptable direct-susceptibility-test results. We used the conventional method to determine that 343 of 519 smear-positive specimens were culture positive for M. tuberculosis, and 212 (62%) produced acceptable results within 3 wks. Conventional results were reported in 3-4 wks, while the time required to obtain results with the BACTEC method ranged from 5 to 21 days (average 11.5 days). Results indicate that the radiometric method provides reportable results more frequently with time savings as compared to the conventional method.

  12. An information theory characterization of radar images and a new definition for radiometric resolution

    NASA Technical Reports Server (NTRS)

    Frost, V. S.; Shanmugan, K. S.; Holtzman, J. C.

    1982-01-01

    The noise properties of the radar image formation process are used in the present modeling of a communication channel in which the desired target properties are the information transmitted, and the final image represents the received signal. The average information rate over this communication channel is calculated together with appropriate bounds and approximations, and is found to be small on a per-sample basis. As a result, many samples must be averaged to allow for the discrimination, or classification, of several levels of target reflectivity. These information rate properties are consistent with known results concerning target detection and image quality in speckle, and the rate is applicable to the definition of radar image radiometric resolution. Radiometric resolution is functionally related to the degree of noncoherent averaging performed by the sensor.

  13. Improved Thermal-Vacuum Compatible Flat Plate Radiometric Source For System-Level Testing Of Optical Sensors

    NASA Technical Reports Server (NTRS)

    Schwarz, Mark A.; Kent, Craig J.; Bousquet, Robert; Brown, Steven W.

    2016-01-01

    In this work, we describe an improved thermal-vacuum compatible flat plate radiometric source which has been developed and utilized for the characterization and calibration of remote optical sensors. This source is unique in that it can be used in situ, in both ambient and thermal-vacuum environments, allowing it to follow the sensor throughout its testing cycle. The performance of the original flat plate radiometric source was presented at the 2009 SPIE1. Following the original efforts, design upgrades were incorporated into the source to improve both radiometric throughput and uniformity. The pre-thermal-vacuum (pre-TVAC) testing results of a spacecraft-level optical sensor with the improved flat plate illumination source, both in ambient and vacuum environments, are presented. We also briefly discuss potential FPI configuration changes in order to improve its radiometric performance.

  14. Summary of the Flight Technology Improvement Workshop. [spaceborne optical radiometric instruments, attitude control, and electromechanical and power subsystems

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Spaceborne instrumentation technology deficiencies are summarized. Recommendations are given for technology development, improvements in existing technology, and policy changes needed to facilitate the use of improved technology. Optical radiometric instruments, attitude control, and electromechanical and power subsystems are considered.

  15. Improved thermal-vacuum compatible flat plate radiometric source for system-level testing of remote optical sensors

    NASA Astrophysics Data System (ADS)

    Schwarz, Mark A.; Kent, Craig J.; Bousquet, Robert; Brown, Steven W.

    2016-09-01

    In this work, we describe an improved thermal-vacuum compatible flat plate radiometric source which has been developed and utilized for the characterization and calibration of remote optical sensors. This source is unique in that it can be used in situ, in both ambient and thermal-vacuum environments, allowing it to follow the sensor throughout its testing cycle. The performance of the original flat plate radiometric source was presented at the 2009 SPIE1. Following the original efforts, design upgrades were incorporated into the source to improve both radiometric throughput and uniformity. The pre-thermal-vacuum (pre-TVAC) testing results of a spacecraft-level optical sensor with the improved flat plate illumination source, both in ambient and vacuum environments, are presented. We also briefly discuss potential FPI configuration changes in order to improve its radiometric performance. Keywords: Calibration, radiometry, remote sensing, source.

  16. Improving Ocean Color Data Products using a Purely Empirical Approach: Reducing the Requirement for Radiometric Calibration Accuracy

    NASA Technical Reports Server (NTRS)

    Gregg, Watson

    2008-01-01

    Radiometric calibration is the foundation upon which ocean color remote sensing is built. Quality derived geophysical products, such as chlorophyll, are assumed to be critically dependent upon the quality of the radiometric calibration. Unfortunately, the goals of radiometric calibration are not typically met in global and large-scale regional analyses, and are especially deficient in coastal regions. The consequences of the uncertainty in calibration are very large in terms of global and regional ocean chlorophyll estimates. In fact, stability in global chlorophyll requires calibration uncertainty much greater than the goals, and outside of modern capabilities. Using a purely empirical approach, we show that stable and consistent global chlorophyll values can be achieved over very wide ranges of uncertainty. Furthermore, the approach yields statistically improved comparisons with in situ data, suggesting improved quality. The results suggest that accuracy requirements for radiometric calibration cab be reduced if alternative empirical approaches are used.

  17. Improving Ocean Color Data Products using a Purely Empirical Approach: Reducing the Requirement for Radiometric Calibration Accuracy

    NASA Technical Reports Server (NTRS)

    Gregg, Watson

    2008-01-01

    Radiometric calibration is the foundation upon which ocean color remote sensing is built. Quality derived geophysical products, such as chlorophyll, are assumed to be critically dependent upon the quality of the radiometric calibration. Unfortunately, the goals of radiometric calibration are not typically met in global and large-scale regional analyses, and are especially deficient in coastal regions. The consequences of the uncertainty in calibration are very large in terms of global and regional ocean chlorophyll estimates. In fact, stability in global chlorophyll requires calibration uncertainty much greater than the goals, and outside of modern capabilities. Using a purely empirical approach, we show that stable and consistent global chlorophyll values can be achieved over very wide ranges of uncertainty. Furthermore, the approach yields statistically improved comparisons with in situ data, suggesting improved quality. The results suggest that accuracy requirements for radiometric calibration cab be reduced if alternative empirical approaches are used.

  18. Automating checks of plan check automation.

    PubMed

    Halabi, Tarek; Lu, Hsiao-Ming

    2014-07-08

    While a few physicists have designed new plan check automation solutions for their clinics, fewer, if any, managed to adapt existing solutions. As complex and varied as the systems they check, these programs must gain the full confidence of those who would run them on countless patient plans. The present automation effort, planCheck, therefore focuses on versatility and ease of implementation and verification. To demonstrate this, we apply planCheck to proton gantry, stereotactic proton gantry, stereotactic proton fixed beam (STAR), and IMRT treatments.

  19. Automation and Cataloging.

    ERIC Educational Resources Information Center

    Furuta, Kenneth; And Others

    1990-01-01

    These three articles address issues in library cataloging that are affected by automation: (1) the impact of automation and bibliographic utilities on professional catalogers; (2) the effect of the LASS microcomputer software on the cost of authority work in cataloging at the University of Arizona; and (3) online subject heading and classification…

  20. Order Division Automated System.

    ERIC Educational Resources Information Center

    Kniemeyer, Justin M.; And Others

    This publication was prepared by the Order Division Automation Project staff to fulfill the Library of Congress' requirement to document all automation efforts. The report was originally intended for internal use only and not for distribution outside the Library. It is now felt that the library community at-large may have an interest in the…

  1. More Benefits of Automation.

    ERIC Educational Resources Information Center

    Getz, Malcolm

    1988-01-01

    Describes a study that measured the benefits of an automated catalog and automated circulation system from the library user's point of view in terms of the value of time saved. Topics discussed include patterns of use, access time, availability of information, search behaviors, and the effectiveness of the measures used. (seven references)…

  2. Work and Programmable Automation.

    ERIC Educational Resources Information Center

    DeVore, Paul W.

    A new industrial era based on electronics and the microprocessor has arrived, an era that is being called intelligent automation. Intelligent automation, in the form of robots, replaces workers, and the new products, using microelectronic devices, require significantly less labor to produce than the goods they replace. The microprocessor thus…

  3. The Automated Office.

    ERIC Educational Resources Information Center

    Naclerio, Nick

    1979-01-01

    Clerical personnel may be able to climb career ladders as a result of office automation and expanded job opportunities in the word processing area. Suggests opportunities in an automated office system and lists books and periodicals on word processing for counselors and teachers. (MF)

  4. Planning for Office Automation.

    ERIC Educational Resources Information Center

    Sherron, Gene T.

    1982-01-01

    The steps taken toward office automation by the University of Maryland are described. Office automation is defined and some types of word processing systems are described. Policies developed in the writing of a campus plan are listed, followed by a section on procedures adopted to implement the plan. (Author/MLW)

  5. WANTED: Fully Automated Indexing.

    ERIC Educational Resources Information Center

    Purcell, Royal

    1991-01-01

    Discussion of indexing focuses on the possibilities of fully automated indexing. Topics discussed include controlled indexing languages such as subject heading lists and thesauri, free indexing languages, natural indexing languages, computer-aided indexing, expert systems, and the need for greater creativity to further advance automated indexing.…

  6. The absolute radiometric calibration of the advanced very high resolution radiometer

    NASA Technical Reports Server (NTRS)

    Slater, P. N.; Teillet, P. M.; Ding, Y.

    1988-01-01

    The need for independent, redundant absolute radiometric calibration methods is discussed with reference to the Thematic Mapper. Uncertainty requirements for absolute calibration of between 0.5 and 4 percent are defined based on the accuracy of reflectance retrievals at an agricultural site. It is shown that even very approximate atmospheric corrections can reduce the error in reflectance retrieval to 0.02 over the reflectance range 0 to 0.4.

  7. Radiometric Characterization of the IKONOS, QuickBird, and OrbView-3 Sensors

    NASA Technical Reports Server (NTRS)

    Holekamp, Kara

    2007-01-01

    The NASA team of University of Arizona, South Dakota State University, and NASA SSC produce consistent results. The OrbView calibration coefficients do not appear to agree well with the NASA team estimate (approx. 20% difference). Discussions with GeoEye (TradeMark) (formerly ORBIMAGE(Registered TradeMark)) personnel are ongoing to update the calibration coefficients. The NASA team will continue to assess OrbView radiometric accuracy.

  8. Emissivity Model Sensitivity on Radiometric Inter-calibration between the GMI and Its Constellation Imager Radiometers

    NASA Astrophysics Data System (ADS)

    Chen, R.

    2015-12-01

    The inter-satellite radiometric calibration technique (also known as XCAL) has been applied with great success between the TRMM Microwave Imager (TMI) -calibration transfer standard- and its constellation imagers, namely, WindSat, AMSR2 and SSMIS. However, while the TRMM mission has now ended, it is now time to change the radiometric transfer standard from the previous TMI to the GPM Microwave Imager (GMI). In this paper, we conduct the inter-calibration between GMI and other imager instruments in its constellation using two different radiative transfer models (RTM), namely XCAL RTM which has been used by XCAL group over the past 10 years, and RSS RTM developed by Remote Sensing Systems (RSS). The main difference between these two RTMs lies in calculating the ocean surface emissivity which is crucial for the measurement of spaceborne microwave radiometers. By comparing the simulated Tb's from two RTMs applied on 9 microwave channels ranging from 10 to 90 GHz, we are able to evaluate the robustness of our XCAL RTM, especially the Elsaesser Ocean Surface Emissivity model that has been used within this model. Besides discussing the reliability of these two RTMs, an XCAL approach known as Double Difference (DD) that has been developed and successfully validated by the Central Florida Remote Sensing Lab will be performed between GMI and its constellation imagers, from which the results will enable us to prescreen the consistency of GMI as the new radiometric transfer standard for imager radiometers as well as assessing the impact of the ocean surface emissivity on radiometric inter-calibration of radiometers at imager channels. Index: Inter-satellite calibration, ocean surface emissivity, radiative transfer model, microwave radiometry

  9. Characterization of Atmospheric Mineral Dust from Radiometric and Polarimetric Remote Sensing

    DTIC Science & Technology

    2007-09-30

    microphysical and optical properties. APPROACH Our approach combines an extensive forward modeling, analysis of laboratory and in-situ data of dust ...Characterization of Atmospheric Mineral Dust from Radiometric and Polarimetric Remote Sensing PI: Dr. Irina N. Sokolik School of Earth and...the properties of mineral aerosols and their interactions with visible and IR atmospheric radiation, and to develop the dust optical models needed

  10. A new automatic system for angular measurement and calibration in radiometric instruments.

    PubMed

    Marquez, Jose Manuel Andujar; Bohórquez, Miguel Ángel Martínez; Garcia, Jonathan Medina; Nieto, Francisco Jose Aguilar

    2010-01-01

    This paper puts forward the design, construction and testing of a new automatic system for angular-response measurement and calibration in radiometric instruments. Its main characteristics include precision, speed, resolution, noise immunity, easy programming and operation. The developed system calculates the cosine error of the radiometer under test by means of a virtual instrument, from the measures it takes and through a mathematical procedure, thus allowing correcting the radiometer with the aim of preventing cosine error in its measurements.

  11. A New Automatic System for Angular Measurement and Calibration in Radiometric Instruments

    PubMed Central

    Marquez, Jose Manuel Andujar; Bohórquez, Miguel Ángel Martínez; Garcia, Jonathan Medina; Nieto, Francisco Jose Aguilar

    2010-01-01

    This paper puts forward the design, construction and testing of a new automatic system for angular-response measurement and calibration in radiometric instruments. Its main characteristics include precision, speed, resolution, noise immunity, easy programming and operation. The developed system calculates the cosine error of the radiometer under test by means of a virtual instrument, from the measures it takes and through a mathematical procedure, thus allowing correcting the radiometer with the aim of preventing cosine error in its measurements. PMID:22319320

  12. Reduction of Striping Noise in Overlapping LIDAR Intensity Data by Radiometric Normalization

    NASA Astrophysics Data System (ADS)

    Yan, Wai Yeung; Shaker, Ahmed

    2016-06-01

    To serve seamless mapping, airborne LiDAR data are usually collected with multiple parallel strips with one or two cross strip(s). Nevertheless, the overlapping regions of LiDAR data strips are usually found with unbalanced intensity values, resulting in the appearance of stripping noise. Despite that physical intensity correction methods are recently proposed, some of the system and environmental parameters are assumed as constant or not disclosed, leading to such an intensity discrepancy. This paper presents a new normalization technique to adjust the radiometric misalignment found in the overlapping LiDAR data strips. The normalization technique is built upon a second-order polynomial function fitted on the joint histogram plot, which is generated with a set of pairwise closest data points identified within the overlapping region. The method was tested on Teledyne Optech's Gemini dataset (at 1064 nm wavelength), where the LiDAR intensity data were first radiometrically corrected based on the radar (range) equation. Five land cover features were selected to evaluate the coefficient of variation (cv) of the intensity values before and after implementing the proposed method. Reduction of cv was found by 19% to 59% in the Gemini dataset, where the striping noise was significantly reduced in the radiometrically corrected and normalized intensity data. The Gemini dataset was also used to conduct land cover classification, and the overall accuracy yielded a notable improvement of 9% to 18%. As a result, LiDAR intensity data should be pre-processed with radiometric correction and normalization prior to any data manipulation.

  13. Impact of the cameras radiometric resolution on the accuracy of determining spectral reflectance coefficients

    NASA Astrophysics Data System (ADS)

    Orych, A.; Walczykowski, P.; Jenerowicz, A.; Zdunek, Z.

    2014-11-01

    Nowadays remote sensing plays a very important role in many different study fields, i.e. environmental studies, hydrology, mineralogy, ecosystem studies, etc. One of the key areas of remote sensing applications is water quality monitoring. Understanding and monitoring of the water quality parameters and detecting different water contaminants is an important issue in water management and protection of whole environment and especially the water ecosystem. There are many remote sensing methods to monitor water quality and detect water pollutants. One of the most widely used method for substance detection with remote sensing techniques is based on usage of spectral reflectance coefficients. They are usually acquired using discrete methods such as spectrometric measurements. These however can be very time consuming, therefore image-based methods are used more and more often. In order to work out the proper methodology of obtaining spectral reflectance coefficients from hyperspectral and multispectral images, it is necessary to verify the impact of cameras radiometric resolution on the accuracy of determination of them. This paper presents laboratory experiments that were conducted using two monochromatic XEVA video sensors (400-1700 nm spectral data registration) with two different radiometric resolutions (12 and 14 bits). In view of determining spectral characteristics from images, the research team used set of interferometric filters. All data collected with multispectral digital video cameras were compared with spectral reflectance coefficients obtained with spectroradiometer. The objective of this research is to find the impact of cameras radiometric resolution on reflectance values in chosen wavelength. The main topic of this study is the analysis of accuracy of spectral coefficients from sensors with different radiometric resolution. By comparing values collected from images acquired with XEVA sensors and with the curves obtained with spectroradiometer it

  14. A procedure for radiometric recalibration of Landsat 5 TM reflective-band data

    USGS Publications Warehouse

    Chander, G.; Haque, M.O.; Micijevic, E.; Barsi, J.A.

    2010-01-01

    From the Landsat program's inception in 1972 to the present, the Earth science user community has been benefiting from a historical record of remotely sensed data. The multispectral data from the Landsat 5 (L5) Thematic Mapper (TM) sensor provide the backbone for this extensive archive. Historically, the radiometric calibration procedure for the L5 TM imagery used the detectors' response to the internal calibrator (IC) on a scene-by-scene basis to determine the gain and offset for each detector. The IC system degraded with time, causing radiometric calibration errors up to 20%. In May 2003, the L5 TM data processed and distributed by the U.S. Geological Survey (USGS) Earth Resources Observation and Science Center through the National Landsat Archive Production System (NLAPS) were updated to use a lifetime lookup-table (LUT) gain model to radiometrically calibrate TM data instead of using scene-specific IC gains. Further modification of the gain model was performed in 2007. The L5 TM data processed using IC prior to the calibration update do not benefit from the recent calibration revisions. A procedure has been developed to give users the ability to recalibrate their existing level-1 products. The best recalibration results are obtained if the work-order report that was included in the original standard data product delivery is available. However, if users do not have the original work-order report, the IC trends can be used for recalibration. The IC trends were generated using the radiometric gain trends recorded in the NLAPS database. This paper provides the details of the recalibration procedure for the following: 1) data processed using IC where users have the work-order file; 2) data processed using IC where users do not have the work-order file; 3) data processed using prelaunch calibration parameters; and 4) data processed using the previous version of the LUT (e.g., LUT03) that was released before April 2, 2007.

  15. Initial Radiometric Calibration of the AWiFS using Vicarious Calibration Techniques

    NASA Technical Reports Server (NTRS)

    Pagnutti, Mary; Thome, Kurtis; Aaron, David; Leigh, Larry

    2006-01-01

    NASA SSC maintains four ASD FieldSpec FR spectroradiometers: 1) Laboratory transfer radiometers; 2) Ground surface reflectance for V&V field collection activities. Radiometric Calibration consists of a NIST-calibrated integrating sphere which serves as a source with known spectral radiance. Spectral Calibration consists of a laser and pen lamp illumination of integrating sphere. Environmental Testing includes temperature stability tests performed in environmental chamber.

  16. Radiometric method for pyrazinamide susceptibility testing of Mycobacterium tuberculosis in egg-yolk-enriched BACTEC 12A medium

    SciTech Connect

    Woodley, C.L.; Smithwick, R.W.

    1988-01-01

    A radiometric method for testing the susceptibility of Mycobacterium tuberculosis to pyrazinamide in egg-yolk-enriched 12A medium (pH 5.5) is described. We obtained 100% agreement between the 7H10 agar method with 25 microgram of pyrazinamide per ml and the modified radiometric method with a drug concentration of 50 microgram/ml in tests of 90 clinical isolates.

  17. Prime candidate earth targets for the post-launch radiometric calibration of space-based optical imaging instruments

    USGS Publications Warehouse

    Teillet, P.M.; Barsi, J.A.; Chander, G.; Thome, K.J.

    2007-01-01

    This paper provides a comprehensive list of prime candidate terrestrial targets for consideration as benchmark sites for the post-launch radiometric calibration of space-based instruments. The key characteristics of suitable sites are outlined primarily with respect to selection criteria, spatial uniformity, and temporal stability. The establishment and utilization of such benchmark sites is considered an important element of the radiometric traceability of satellite image data products for use in the accurate monitoring of environmental change.

  18. Advances in inspection automation

    NASA Astrophysics Data System (ADS)

    Weber, Walter H.; Mair, H. Douglas; Jansen, Dion; Lombardi, Luciano

    2013-01-01

    This new session at QNDE reflects the growing interest in inspection automation. Our paper describes a newly developed platform that makes the complex NDE automation possible without the need for software programmers. Inspection tasks that are tedious, error-prone or impossible for humans to perform can now be automated using a form of drag and drop visual scripting. Our work attempts to rectify the problem that NDE is not keeping pace with the rest of factory automation. Outside of NDE, robots routinely and autonomously machine parts, assemble components, weld structures and report progress to corporate databases. By contrast, components arriving in the NDT department typically require manual part handling, calibrations and analysis. The automation examples in this paper cover the development of robotic thickness gauging and the use of adaptive contour following on the NRU reactor inspection at Chalk River.

  19. Automation in Immunohematology

    PubMed Central

    Bajpai, Meenu; Kaur, Ravneet; Gupta, Ekta

    2012-01-01

    There have been rapid technological advances in blood banking in South Asian region over the past decade with an increasing emphasis on quality and safety of blood products. The conventional test tube technique has given way to newer techniques such as column agglutination technique, solid phase red cell adherence assay, and erythrocyte-magnetized technique. These new technologies are adaptable to automation and major manufacturers in this field have come up with semi and fully automated equipments for immunohematology tests in the blood bank. Automation improves the objectivity and reproducibility of tests. It reduces human errors in patient identification and transcription errors. Documentation and traceability of tests, reagents and processes and archiving of results is another major advantage of automation. Shifting from manual methods to automation is a major undertaking for any transfusion service to provide quality patient care with lesser turnaround time for their ever increasing workload. This article discusses the various issues involved in the process. PMID:22988378

  20. Relative Radiometric Normalization and Atmospheric Correction of a SPOT 5 Time Series

    PubMed Central

    Hajj, Mahmoud El; Bégué, Agnès; Lafrance, Bruno; Hagolle, Olivier; Dedieu, Gérard; Rumeau, Matthieu

    2008-01-01

    Multi-temporal images acquired at high spatial and temporal resolution are an important tool for detecting change and analyzing trends, especially in agricultural applications. However, to insure a reliable use of this kind of data, a rigorous radiometric normalization step is required. Normalization can be addressed by performing an atmospheric correction of each image in the time series. The main problem is the difficulty of obtaining an atmospheric characterization at a given acquisition date. In this paper, we investigate whether relative radiometric normalization can substitute for atmospheric correction. We develop an automatic method for relative radiometric normalization based on calculating linear regressions between unnormalized and reference images. Regressions are obtained using the reflectances of automatically selected invariant targets. We compare this method with an atmospheric correction method that uses the 6S model. The performances of both methods are compared using 18 images from of a SPOT 5 time series acquired over Reunion Island. Results obtained for a set of manually selected invariant targets show excellent agreement between the two methods in all spectral bands: values of the coefficient of determination (r2 exceed 0.960, and bias magnitude values are less than 2.65. There is also a strong correlation between normalized NDVI values of sugarcane fields (r2 = 0.959). Despite a relative error of 12.66% between values, very comparable NDVI patterns are observed. PMID:27879849

  1. Comparison of the spatial and radiometric resolution of ERS and Metop C-band radars

    NASA Astrophysics Data System (ADS)

    Elyouncha, Anis; Neyt, Xavier

    2014-10-01

    ERS-1/2 and Metop-A/B satellites carry a very similar radars operating at similar frequencies (5.3/5.255 GHz) and same polarization (VV). However, the radars on-board the satellites of these two missions differ in the pulse waveform, bandwidth and slightly in geometry. Moreover, the on-board and the on-ground processing is different. This paper investigates the spatial and radiometric resolution of these radars and the resolution enhancement between ERS (1991-2011) and Metop (2006- ) missions. The spatial resolution assessment implies the computation and the comparison of the Spatial Response Function (SRF) of both systems. The SRF involves mainly the antenna gain pattern, the pulse waveform and the different on-board filtering stages. The radiometric resolution depends mainly on the signal to noise ratio (SNR) and the number of averaged independent samples (N). Furthermore, the correlation of the measurement samples in a resolution cell is computed to assess the independence assumption. The metric used to quantify the radiometric accuracy in scatterometry is called Kp which is the relative standard deviation. A comparison of Kp parameter extracted from the nominal products of the two missions confirms the expected performance based on the SNR, N and correlation analysis.

  2. Radiometric 81Kr dating identifies 120,000-year-old ice at Taylor Glacier, Antarctica.

    PubMed

    Buizert, Christo; Baggenstos, Daniel; Jiang, Wei; Purtschert, Roland; Petrenko, Vasilii V; Lu, Zheng-Tian; Müller, Peter; Kuhl, Tanner; Lee, James; Severinghaus, Jeffrey P; Brook, Edward J

    2014-05-13

    We present successful (81)Kr-Kr radiometric dating of ancient polar ice. Krypton was extracted from the air bubbles in four ∼350-kg polar ice samples from Taylor Glacier in the McMurdo Dry Valleys, Antarctica, and dated using Atom Trap Trace Analysis (ATTA). The (81)Kr radiometric ages agree with independent age estimates obtained from stratigraphic dating techniques with a mean absolute age offset of 6 ± 2.5 ka. Our experimental methods and sampling strategy are validated by (i) (85)Kr and (39)Ar analyses that show the samples to be free of modern air contamination and (ii) air content measurements that show the ice did not experience gas loss. We estimate the error in the (81)Kr ages due to past geomagnetic variability to be below 3 ka. We show that ice from the previous interglacial period (Marine Isotope Stage 5e, 130-115 ka before present) can be found in abundance near the surface of Taylor Glacier. Our study paves the way for reliable radiometric dating of ancient ice in blue ice areas and margin sites where large samples are available, greatly enhancing their scientific value as archives of old ice and meteorites. At present, ATTA (81)Kr analysis requires a 40-80-kg ice sample; as sample requirements continue to decrease, (81)Kr dating of ice cores is a future possibility.

  3. The Radiometric Calibration Network (RadCalNet): a Global Calibration and Validation Test Site Network

    NASA Astrophysics Data System (ADS)

    Czapla-Myers, J.; Bouvet, M.; Wenny, B. N.

    2016-12-01

    The Radiometric Calibration Network (RadCalNet) Working Group (WG) consists of national and academic groups from various countries who are involved in the radiometric calibration and validation of Earth-observing sensors. The current WG is composed of members from France, Italy, the Netherlands, the UK, the USA, and China. RadCalNet has been on the agenda of the Committee on Earth Observation Satellites (CEOS) Working Group on Calibration and Validation (WGCV) for years, and in 2014 it was formally assembled. The primary goal is to develop an SI-traceable standardized network of sites and processing protocols for the absolute radiometric calibration, Intercalibration, and validation of Earth-observing sensors. Currently, RadCalNet is composed of four instrumented test sites that are located in the USA, France, Namibia, and China. A two-year prototyping phase was used to define the architecture of RadCalNet, demonstrate the operational concept using current satellite sensors, and to provide recommendations to CEOS WGCV for the transition of RadCalNet to an operational status. The final product is planned to be a daily hyperspectral (400-2500 nm) top-of-atmosphere reflectance in 30-minute intervals for a nadir-viewing sensor at each of the four test sites. The current schedule has RadCalNet becoming operational in late 2016 or early 2017.

  4. Spatial-Temporal Variation of the Radiometric Color of the Largest Ten Lakes in China

    NASA Astrophysics Data System (ADS)

    Li, J.

    2016-02-01

    The optical properties of inland waters are complicated, limiting the use of remote sensing to monitor inland water quality in large regions over long time periods. The radiometric color of water, reflecting overall water quality, is an important parameter in traditional water quality investigations. In this study, we retrieved the Forel-Ule (FU) class radiometric color parameters from MODIS surface reflectance product (MOD09) image, and analyzed its long term time-series variation in the largest ten lakes in China during 2000-2012. Based on validation by in situ measured reflectance data, the MOD09-derived FU products are reliable, with a linear correlation coefficient of 0.97, RMSE of 1.2, and average relative error of 7.7%. Since FU class is an optical parameter, it can be derived from optical remote sensing data without seasonal and area limitations. The FU class products were used to analyze the spatial and temporal variations of turbidity and trophic states in the ten lakes. The largest ten lakes in China include typical types with different optical properties, so the FU class can also be used to assess the quality of other inland waters. The FU class retrieval method can also be applied to other remote sensing data after a simple normalization process. As a result, the FU class radiometric color can be used to assess inland water quality in large regions over long time periods.

  5. Inflight Radiometric Calibration of New Horizons' Multispectral Visible Imaging Camera (MVIC)

    NASA Technical Reports Server (NTRS)

    Howett, C. J. A.; Parker, A. H.; Olkin, C. B.; Reuter, D. C.; Ennico, K.; Grundy, W. M.; Graps, A. L.; Harrison, K. P.; Throop, H. B.; Buie, M. W.; hide

    2016-01-01

    We discuss two semi-independent calibration techniques used to determine the inflight radiometric calibration for the New Horizons Multi-spectral Visible Imaging Camera (MVIC). The first calibration technique compares the measured number of counts (DN) observed from a number of well calibrated stars to those predicted using the component-level calibration. The ratio of these values provides a multiplicative factor that allows a conversation between the preflight calibration to the more accurate inflight one, for each detector. The second calibration technique is a channel-wise relative radiometric calibration for MVIC's blue, near-infrared and methane color channels using Hubble and New Horizons observations of Charon and scaling from the red channel stellar calibration. Both calibration techniques produce very similar results (better than 7% agreement), providing strong validation for the techniques used. Since the stellar calibration described here can be performed without a color target in the field of view and covers all of MVIC's detectors, this calibration was used to provide the radiometric keyword values delivered by the New Horizons project to the Planetary Data System (PDS). These keyword values allow each observation to be converted from counts to physical units; a description of how these keyword values were generated is included. Finally, mitigation techniques adopted for the gain drift observed in the near-infrared detector and one of the panchromatic framing cameras are also discussed.

  6. Radiometric Calibration of a Dual-Wavelength, Full-Waveform Terrestrial Lidar

    PubMed Central

    Li, Zhan; Jupp, David L. B.; Strahler, Alan H.; Schaaf, Crystal B.; Howe, Glenn; Hewawasam, Kuravi; Douglas, Ewan S.; Chakrabarti, Supriya; Cook, Timothy A.; Paynter, Ian; Saenz, Edward J.; Schaefer, Michael

    2016-01-01

    Radiometric calibration of the Dual-Wavelength Echidna® Lidar (DWEL), a full-waveform terrestrial laser scanner with two simultaneously-pulsing infrared lasers at 1064 nm and 1548 nm, provides accurate dual-wavelength apparent reflectance (ρapp), a physically-defined value that is related to the radiative and structural characteristics of scanned targets and independent of range and instrument optics and electronics. The errors of ρapp are 8.1% for 1064 nm and 6.4% for 1548 nm. A sensitivity analysis shows that ρapp error is dominated by range errors at near ranges, but by lidar intensity errors at far ranges. Our semi-empirical model for radiometric calibration combines a generalized logistic function to explicitly model telescopic effects due to defocusing of return signals at near range with a negative exponential function to model the fall-off of return intensity with range. Accurate values of ρapp from the radiometric calibration improve the quantification of vegetation structure, facilitate the comparison and coupling of lidar datasets from different instruments, campaigns or wavelengths and advance the utilization of bi- and multi-spectral information added to 3D scans by novel spectral lidars. PMID:26950126

  7. Radiometric 81Kr dating identifies 120,000-year-old ice at Taylor Glacier, Antarctica

    PubMed Central

    Buizert, Christo; Baggenstos, Daniel; Jiang, Wei; Purtschert, Roland; Petrenko, Vasilii V.; Lu, Zheng-Tian; Müller, Peter; Kuhl, Tanner; Lee, James; Severinghaus, Jeffrey P.; Brook, Edward J.

    2014-01-01

    We present successful 81Kr-Kr radiometric dating of ancient polar ice. Krypton was extracted from the air bubbles in four ∼350-kg polar ice samples from Taylor Glacier in the McMurdo Dry Valleys, Antarctica, and dated using Atom Trap Trace Analysis (ATTA). The 81Kr radiometric ages agree with independent age estimates obtained from stratigraphic dating techniques with a mean absolute age offset of 6 ± 2.5 ka. Our experimental methods and sampling strategy are validated by (i) 85Kr and 39Ar analyses that show the samples to be free of modern air contamination and (ii) air content measurements that show the ice did not experience gas loss. We estimate the error in the 81Kr ages due to past geomagnetic variability to be below 3 ka. We show that ice from the previous interglacial period (Marine Isotope Stage 5e, 130–115 ka before present) can be found in abundance near the surface of Taylor Glacier. Our study paves the way for reliable radiometric dating of ancient ice in blue ice areas and margin sites where large samples are available, greatly enhancing their scientific value as archives of old ice and meteorites. At present, ATTA 81Kr analysis requires a 40–80-kg ice sample; as sample requirements continue to decrease, 81Kr dating of ice cores is a future possibility. PMID:24753606

  8. Calibrating Late Quaternary terrestrial climate signals: radiometrically dated pollen evidence from the southern Sierra Nevada, USA

    USGS Publications Warehouse

    Litwin, Ronald J.; Smoot, Joseph P.; Durika, Nancy J.; Smith, George I.

    1999-01-01

    We constructed a radiometrically calibrated proxy record of Late Pleistocene and Holocene climate change exceeding 230,000 yr duration, using pollen profiles from two cores taken through age-equivalent dry lakes - one core having greater age control (via 230Th alpha mass-spectrometry) and the other having greater stratigraphic completeness. The better dated of these two serial pollen records (Searles Lake) served as a reference section for improving the effective radiometric age control in a nearby and more complete pollen record (Owens Lake) because they: (1) are situated ~90 km apart in the same drainage system (on, and immediately leeward of, the eastern flank of the Sierra Nevada), and (2) preserved strikingly similar pollen profiles and concordant sequences of sedimentological changes. Pollen assemblages from both lakes are well preserved and diverse, and document serial changes in Late Pleistocene and Holocene plant zone distribution and composition in the westernmost Great Basin; they consist of taxa now inhabiting montane forest, woodland, steppe, and desert-scrub environments. The studied core intervals are interpreted here to be the terrestrial equivalent of marine δ18O stages 1 through 9; these pollen profiles now appear to be among the best radiometrically dated Late Pleistocene records of terrestrial climate change known.

  9. Designing an in-flight airborne calibration site using experience from vicarious radiometric satellite calibration

    NASA Astrophysics Data System (ADS)

    Livens, Stefan; Debruyn, Walter; Sterckx, Sindy; Reusen, Ils

    2011-11-01

    Laboratory calibration of electro-optical sensors is preferably complemented by regular in-flight verification. This checks whether the lab calibration parameters remain valid or recalibration is necessary. In-flight verification can be achieved by vicarious calibration using in-flight measurements of calibration targets. We intend to identify and design a set of suitable radiometric calibration targets. For this, we borrow from expertise gained with the PROBA-V satellite calibration system, which uses multiple vicarious methods relying on diverse natural on-ground targets. Besides reflectance based calibration using ground measurements, the PROBA-V calibration methods are unproven for use in airborne calibration. The selected targets should be suitable for the calibration of both multispectral and hyperspectral imagers. We start from general requirements for radiometric targets and investigate their applicability to airborne calibration. From this we identify two possible sets of natural calibration sites in Belgium. One set, located in the Campine region, contains small water bodies and sandy lakesides. Another set is located in the Westhoek region near the Belgian coast. It offers better suitable water bodies, as well as sandy areas, grass fields and dark targets. Airborne calibration lends itself to the use of smaller artifical targets. We propose to complement the natural targets with a portable target consisting of agricultural nets with different densities. The definition of sets of calibration targets, both natural and artificial can facilitate the investigation of the usability of vicarious targets and method for inflight radiometric verification.

  10. Assessment of SNPP VIIRS VIS NIR Radiometric Calibration Stability Using Aqua MODIS and Invariant Surface Targets

    NASA Technical Reports Server (NTRS)

    Wu, Aisheng; Xiong, Xiaoxiong; Cao, Changyong; Chiang, Kwo-Fu

    2016-01-01

    The first Visible Infrared Imaging Radiometer Suite (VIIRS) is onboard the Suomi National Polar-orbiting Partnership (SNPP) satellite. As a primary sensor, it collects imagery and radiometric measurements of the land, atmosphere, cryosphere, and oceans in the spectral regions from visible (VIS) to long-wave infrared. NASA's National Polar-orbiting Partnership (NPP) VIIRS Characterization Support Team has been actively involved in the VIIRS radiometric and geometric calibration to support its Science Team Principal Investigators for their independent quality assessment of VIIRS Environmental Data Records. This paper presents the performance assessment of the radiometric calibration stability of the VIIRS VIS and NIR spectral bands using measurements from SNPP VIIRS and Aqua MODIS simultaneous nadir overpasses and over the invariant surface targets at the Libya-4 desert and Antarctic Dome Concordia snow sites. The VIIRS sensor data records (SDRs) used in this paper are reprocessed by the NASA SNPP Land Product Evaluation and Analysis Tool Element. This paper shows that the reprocessed VIIRS SDRs have been consistently calibrated from the beginning of the mission, and the calibration stability is similar to or better than MODIS. Results from different approaches indicate that the calibrations of the VIIRS VIS and NIR spectral bands are maintained to be stable to within 1% over the first three-year mission. The absolute calibration differences between VIIRS and MODIS are within 2%, with an exception for the 0.865-m band, after correction of their spectral response differences.

  11. Radiometric resolution enhancement by lossy compression as compared to truncation followed by lossless compression

    NASA Technical Reports Server (NTRS)

    Tilton, James C.; Manohar, Mareboyana

    1994-01-01

    Recent advances in imaging technology make it possible to obtain imagery data of the Earth at high spatial, spectral and radiometric resolutions from Earth orbiting satellites. The rate at which the data is collected from these satellites can far exceed the channel capacity of the data downlink. Reducing the data rate to within the channel capacity can often require painful trade-offs in which certain scientific returns are sacrificed for the sake of others. In this paper we model the radiometric version of this form of lossy compression by dropping a specified number of least significant bits from each data pixel and compressing the remaining bits using an appropriate lossless compression technique. We call this approach 'truncation followed by lossless compression' or TLLC. We compare the TLLC approach with applying a lossy compression technique to the data for reducing the data rate to the channel capacity, and demonstrate that each of three different lossy compression techniques (JPEG/DCT, VQ and Model-Based VQ) give a better effective radiometric resolution than TLLC for a given channel rate.

  12. A Study on Optimal Strategy in Relative Radiometric Calibration for Optical Sensors

    PubMed Central

    Yu, Kai; Liu, Suhong; Zhao, Yongchao

    2017-01-01

    Based on the analysis of three main factors involved in the relative radiometric calibration for optical sensors, namely: the number of radiance level; the number of measurements at each level; and the radiance level grouping method, an optimal strategy is presented in this paper for relative radiometric calibration. First, the maximization to the possible extent of either the number of the radiance level or the number of measurements at each level can improve the precision of the calibration results, where the recommended number of measurements is no less than 20. Second, when the number of the radiance level is divisible by four, dividing all the levels evenly into four groups by intensity gradient order and conducting averages for each group could achieve calibration results with the highest precision, which is higher than the result of no grouping or any other grouping method with the mean square error being 22Mn/IT (where Mn is the mean square error of noise in the calibration data, I is the number of the radiance level, and T is the number of measurements for each level. In this case, the first two factors had an equivalent effect and showed their strongest effect on the precision. Third, when the calibration data were not evenly divided, the number of measurements demonstrated a stronger effect than the number of the radiance level. These cognitions are helping to achieve more precise relative radiometric calibration of optical sensors. PMID:28257083

  13. Validation analysis of the thermal and radiometric integrity of RIT's synthetic image generation model, DIRSIG

    NASA Astrophysics Data System (ADS)

    Mason, John E.; Schott, John R.; Rankin-Parobek, Donna

    1994-06-01

    The digital imaging and remote sensing laboratory's image generation model (DIRSIG) was validated in the long wave infrared (LWIR, 8 - 13.3 micrometers ) and midwife infrared (MWIR, 3 - 5 micrometers ) pass bands. Truth data was collected for all components of the thermal and radiometric submodels including a complete set of meteorological and radiometric data. Truth temperatures were collected using a bank of thermistors and truth radiance images were collected with calibrated InSb (MWIR) and HgCdTe (LWIR) detectors. Sensor spectral response functions were also included in the radiometric analysis. Relative error contributions to the total temperature/radiance digital count were investigated for each component in the multi-spectral model. Largest contributions were found to be wind speed, air temperature, visible emissivity, and fractional sky exposure for the thermal model and atmospheric transmission, temperature, and emissivity for the radiance model. An overall comparison of truth and synthetic images yields rms errors of as low as 1.8 degree(s)C actual temperature and 5 degree(s)C (LWIR) and 6 degree(s)C (MWIR) apparent temperature.

  14. Long-Term Radiometric Performance of the SCIAMACHY Quartz Tungsten Halogen Lamp

    NASA Astrophysics Data System (ADS)

    Noël, S.; Bramstedt, K.; Bovensmann, H.; Burrows, J. P.; Gottwald, M.; Krieg, E.

    2009-04-01

    The SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY) is part of the atmospheric chemistry payload of ESAś Environmental Satellite ENVISAT. Since 2002, SCIAMACHY provides the amount and global distribution of various atmospheric constituents relevant in the contexts of ozone chemistry, air pollution and climate change. Originally designed for a 5-year mission, the SCIAMACHY instrument is still working well and ready for the planned mission extension until 2010 or even further. Calibration and monitoring of the instrument performance are a pre-requisite for a continuously high data product quality. Here, results from the monitoring of the optical performance of the SCIAMACHY instrument are presented. Emphasis is placed on the investigation of the performance of the SCIAMACHY internal Quartz Tungsten Halogen (QTH) lamp. This type of lamp has been used for monitoring the radiometric performance of an UV-VIS-SWIR Earth observation sensor over mission lifetime for the first time. The analysis of regular in-flight measurements has shown the radiometric stability of the SCIAMACHY QTH lamp over time especially in the visible/NIR spectral range. Lamps of this type are therefore considered as useful components for further space-borne spectroscopic missions, as they provide a relatively cheap and reliable mean for (at least relative) radiometric calibration and monitoring.

  15. Inflight radiometric calibration of New Horizons' Multispectral Visible Imaging Camera (MVIC)

    NASA Astrophysics Data System (ADS)

    Howett, C. J. A.; Parker, A. H.; Olkin, C. B.; Reuter, D. C.; Ennico, K.; Grundy, W. M.; Graps, A. L.; Harrison, K. P.; Throop, H. B.; Buie, M. W.; Lovering, J. R.; Porter, S. B.; Weaver, H. A.; Young, L. A.; Stern, S. A.; Beyer, R. A.; Binzel, R. P.; Buratti, B. J.; Cheng, A. F.; Cook, J. C.; Cruikshank, D. P.; Dalle Ore, C. M.; Earle, A. M.; Jennings, D. E.; Linscott, I. R.; Lunsford, A. W.; Parker, J. W. m.; Phillippe, S.; Protopapa, S.; Quirico, E.; Schenk, P. M.; Schmitt, B.; Singer, K. N.; Spencer, J. R.; Stansberry, J. A.; Tsang, C. C. C.; Weigle, G. E.; Verbiscer, A. J.

    2017-05-01

    We discuss two semi-independent calibration techniques used to determine the inflight radiometric calibration for the New Horizons' Multi-spectral Visible Imaging Camera (MVIC). The first calibration technique compares the measured number of counts (DN) observed from a number of well calibrated stars to those predicted using the component-level calibration. The ratio of these values provides a multiplicative factor that allows a conversation between the preflight calibration to the more accurate inflight one, for each detector. The second calibration technique is a channel-wise relative radiometric calibration for MVIC's blue, near-infrared and methane color channels using Hubble and New Horizons observations of Charon and scaling from the red channel stellar calibration. Both calibration techniques produce very similar results (better than 7% agreement), providing strong validation for the techniques used. Since the stellar calibration described here can be performed without a color target in the field of view and covers all of MVIC's detectors, this calibration was used to provide the radiometric keyword values delivered by the New Horizons project to the Planetary Data System (PDS). These keyword values allow each observation to be converted from counts to physical units; a description of how these keyword values were generated is included. Finally, mitigation techniques adopted for the gain drift observed in the near-infrared detector and one of the panchromatic framing cameras are also discussed.

  16. Radiometric Calibration of a Dual-Wavelength, Full-Waveform Terrestrial Lidar.

    PubMed

    Li, Zhan; Jupp, David L B; Strahler, Alan H; Schaaf, Crystal B; Howe, Glenn; Hewawasam, Kuravi; Douglas, Ewan S; Chakrabarti, Supriya; Cook, Timothy A; Paynter, Ian; Saenz, Edward J; Schaefer, Michael

    2016-03-02

    Radiometric calibration of the Dual-Wavelength Echidna(®) Lidar (DWEL), a full-waveform terrestrial laser scanner with two simultaneously-pulsing infrared lasers at 1064 nm and 1548 nm, provides accurate dual-wavelength apparent reflectance (ρ(app)), a physically-defined value that is related to the radiative and structural characteristics of scanned targets and independent of range and instrument optics and electronics. The errors of ρ(app) are 8.1% for 1064 nm and 6.4% for 1548 nm. A sensitivity analysis shows that ρ(app) error is dominated by range errors at near ranges, but by lidar intensity errors at far ranges. Our semi-empirical model for radiometric calibration combines a generalized logistic function to explicitly model telescopic effects due to defocusing of return signals at near range with a negative exponential function to model the fall-off of return intensity with range. Accurate values of ρ(app) from the radiometric calibration improve the quantification of vegetation structure, facilitate the comparison and coupling of lidar datasets from different instruments, campaigns or wavelengths and advance the utilization of bi- and multi-spectral information added to 3D scans by novel spectral lidars.

  17. Improved detection of Mycobacterium avium complex with the Bactec radiometric system

    SciTech Connect

    Hoffner, S.E.

    1988-05-01

    A reconsideration of the laboratory methods used for primary isolation of mycobacteria other than Mycobacterium tuberculosis is needed due to the increasingly recognized importance of such mycobacterial infections in immunocompromised patients. One example of this is the severe opportunistic infections caused by Mycobacterium avium complex among AIDS patients. In this study, the Bactec radiometric system was compared to conventional culture on solid medium for the detection of M. avium complex in 3,612 selected clinical specimens, mainly of extrapulmonary origin. Of a total number of 63 M. avium complex isolates, the Bactec system detected 58 (92%), compared to 37 (59%) for conventional culture. A much more rapid detection was attained with radiometric technique than with conventional culture. The mean detection time for the cultures positive with both methods was 7.1 and 28.3 days, respectively. The Bactec radiometric system achieves a rapid and significantly more sensitive detection and seems to be an excellent complement to conventional culture in the laboratory diagnosis of infections with the M. avium complex.

  18. Systematic review automation technologies.

    PubMed

    Tsafnat, Guy; Glasziou, Paul; Choong, Miew Keen; Dunn, Adam; Galgani, Filippo; Coiera, Enrico

    2014-07-09

    Systematic reviews, a cornerstone of evidence-based medicine, are not produced quickly enough to support clinical practice. The cost of production, availability of the requisite expertise and timeliness are often quoted as major contributors for the delay. This detailed survey of the state of the art of information systems designed to support or automate individual tasks in the systematic review, and in particular systematic reviews of randomized controlled clinical trials, reveals trends that see the convergence of several parallel research projects.We surveyed literature describing informatics systems that support or automate the processes of systematic review or each of the tasks of the systematic review. Several projects focus on automating, simplifying and/or streamlining specific tasks of the systematic review. Some tasks are already fully automated while others are still largely manual. In this review, we describe each task and the effect that its automation would have on the entire systematic review process, summarize the existing information system support for each task, and highlight where further research is needed for realizing automation for the task. Integration of the systems that automate systematic review tasks may lead to a revised systematic review workflow. We envisage the optimized workflow will lead to system in which each systematic review is described as a computer program that automatically retrieves relevant trials, appraises them, extracts and synthesizes data, evaluates the risk of bias, performs meta-analysis calculations, and produces a report in real time.

  19. Systematic review automation technologies

    PubMed Central

    2014-01-01

    Systematic reviews, a cornerstone of evidence-based medicine, are not produced quickly enough to support clinical practice. The cost of production, availability of the requisite expertise and timeliness are often quoted as major contributors for the delay. This detailed survey of the state of the art of information systems designed to support or automate individual tasks in the systematic review, and in particular systematic reviews of randomized controlled clinical trials, reveals trends that see the convergence of several parallel research projects. We surveyed literature describing informatics systems that support or automate the processes of systematic review or each of the tasks of the systematic review. Several projects focus on automating, simplifying and/or streamlining specific tasks of the systematic review. Some tasks are already fully automated while others are still largely manual. In this review, we describe each task and the effect that its automation would have on the entire systematic review process, summarize the existing information system support for each task, and highlight where further research is needed for realizing automation for the task. Integration of the systems that automate systematic review tasks may lead to a revised systematic review workflow. We envisage the optimized workflow will lead to system in which each systematic review is described as a computer program that automatically retrieves relevant trials, appraises them, extracts and synthesizes data, evaluates the risk of bias, performs meta-analysis calculations, and produces a report in real time. PMID:25005128

  20. Automation synthesis modules review.

    PubMed

    Boschi, S; Lodi, F; Malizia, C; Cicoria, G; Marengo, M

    2013-06-01

    The introduction of (68)Ga labelled tracers has changed the diagnostic approach to neuroendocrine tumours and the availability of a reliable, long-lived (68)Ge/(68)Ga generator has been at the bases of the development of (68)Ga radiopharmacy. The huge increase in clinical demand, the impact of regulatory issues and a careful radioprotection of the operators have boosted for extensive automation of the production process. The development of automated systems for (68)Ga radiochemistry, different engineering and software strategies and post-processing of the eluate were discussed along with impact of automation with regulations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Managing laboratory automation

    PubMed Central

    Saboe, Thomas J.

    1995-01-01

    This paper discusses the process of managing automated systems through their life cycles within the quality-control (QC) laboratory environment. The focus is on the process of directing and managing the evolving automation of a laboratory; system examples are given. The author shows how both task and data systems have evolved, and how they interrelate. A BIG picture, or continuum view, is presented and some of the reasons for success or failure of the various examples cited are explored. Finally, some comments on future automation need are discussed. PMID:18925018

  2. Evolution of Scientific and Technical Information Distribution

    NASA Technical Reports Server (NTRS)

    Esler, Sandra; Nelson, Michael L.

    1998-01-01

    World Wide Web (WWW) and related information technologies are transforming the distribution of scientific and technical information (STI). We examine 11 recent, functioning digital libraries focusing on the distribution of STI publications, including journal articles, conference papers, and technical reports. We introduce 4 main categories of digital library projects: based on the architecture (distributed vs. centralized) and the contributor (traditional publisher vs. authoring individual/organization). Many digital library prototypes merely automate existing publishing practices or focus solely on the digitization of the publishing cycle output, not sampling and capturing elements of the input. Still others do not consider for distribution the large body of "gray literature." We address these deficiencies in the current model of STI exchange by suggesting methods for expanding the scope and target of digital libraries by focusing on a greater source of technical publications and using "buckets," an object-oriented construct for grouping logically related information objects, to include holdings other than technical publications.

  3. Xenon International Automated Control

    SciTech Connect

    2016-08-05

    The Xenon International Automated Control software monitors, displays status, and allows for manual operator control as well as fully automatic control of multiple commercial and PNNL designed hardware components to generate and transmit atmospheric radioxenon concentration measurements every six hours.

  4. Automating the Media Center.

    ERIC Educational Resources Information Center

    Holloway, Mary A.

    1988-01-01

    Discusses the need to develop more efficient information retrieval skills by the use of new technology. Lists four stages used in automating the media center. Describes North Carolina's pilot programs. Proposes benefits and looks at the media center's future. (MVL)

  5. Planning for Office Automation.

    ERIC Educational Resources Information Center

    Mick, Colin K.

    1983-01-01

    Outlines a practical approach to planning for office automation termed the "Focused Process Approach" (the "what" phase, "how" phase, "doing" phase) which is a synthesis of the problem-solving and participatory planning approaches. Thirteen references are provided. (EJS)

  6. Automated decision stations

    NASA Technical Reports Server (NTRS)

    Tischendorf, Mark

    1990-01-01

    This paper discusses the combination of software robots and expert systems to automate everyday business tasks. Tasks which require people to repetitively interact with multiple systems screens as well as multiple systems.

  7. AUTOMATION IN LIBRARIES, ATLIS WORKSHOP (1ST, NOVEMBER 15-17, 1966).

    ERIC Educational Resources Information Center

    Redstone Scientific Information Center, Redstone Arsenal, AL.

    THIS REPORT CONTAINS THE MINUTES OF A WORKSHOP ON AUTOMATION IN LIBRARIES, HELD TO IMPROVE THE EFFECTIVENESS OF ARMY TECHNICAL LIBRARIES AND SPONSORED BY ARMY TECHNICAL LIBRARY IMPROVEMENT STUDIES (ATLIS). THE PROGRAM WAS DEVELOPED IN FOUR AREAS, EACH ILLUSTRATED WITH PRESENTATIONS BY PEOPLE ACTUALLY INVOLVED IN THESE SYSTEMS. THE FIRST SESSION…

  8. NREL Research and Thoughts on Connected and Automated Vehicle Energy Impacts; NREL (National Renewable Energy Laboratory)

    SciTech Connect

    Gonder, Jeff; Wood, Eric; Lammert, Michael

    2014-12-09

    Jeff was invited to brief the EPA Mobile Sources Technical Review Subcommittee on considerations regarding potential energy and environmental considerations for connected and automated vehicles. For more information about the MSTRS see http://www2.epa.gov/caaac/mobile-sources-technical-review-subcommittee-mstrs-caaac.

  9. Automated Status Notification System

    NASA Technical Reports Server (NTRS)

    2005-01-01

    NASA Lewis Research Center's Automated Status Notification System (ASNS) was born out of need. To prevent "hacker attacks," Lewis' telephone system needed to monitor communications activities 24 hr a day, 7 days a week. With decreasing staff resources, this continuous monitoring had to be automated. By utilizing existing communications hardware, a UNIX workstation, and NAWK (a pattern scanning and processing language), we implemented a continuous monitoring system.

  10. Automated Microfluidics for Genomics

    DTIC Science & Technology

    2001-10-25

    Abstract--The Genomation Laboratory at the University of Washington is developing an automated fluid handling system called " Acapella " to prepare...Photonic Systems, Inc. (Redmond, WA), an automated submicroliter fluid sample preparation system called ACAPELLA is being developed. Reactions such...technology include minimal residual disease quantification and sample preparation for DNA. Preliminary work on the ACAPELLA is presented in [4][5]. This

  11. Automated Pilot Advisory System

    NASA Technical Reports Server (NTRS)

    Parks, J. L., Jr.; Haidt, J. G.

    1981-01-01

    An Automated Pilot Advisory System (APAS) was developed and operationally tested to demonstrate the concept that low cost automated systems can provide air traffic and aviation weather advisory information at high density uncontrolled airports. The system was designed to enhance the see and be seen rule of flight, and pilots who used the system preferred it over the self announcement system presently used at uncontrolled airports.

  12. Automating Index Preparation

    DTIC Science & Technology

    1987-03-23

    Automating Index Preparation* Pehong Chent Michael A. Harrison Computer Science Division University of CaliforniaI Berkeley, CA 94720 March 23, 1987...Abstract Index preparation is a tedious and time-consuming task. In this paper we indicate * how the indexing process can be automated in a way which...identified and analyzed. Specifically, we describe a framework for placing index commands in the document and a general purpose index processor which

  13. Automated Lattice Perturbation Theory

    SciTech Connect

    Monahan, Christopher

    2014-11-01

    I review recent developments in automated lattice perturbation theory. Starting with an overview of lattice perturbation theory, I focus on the three automation packages currently "on the market": HiPPy/HPsrc, Pastor and PhySyCAl. I highlight some recent applications of these methods, particularly in B physics. In the final section I briefly discuss the related, but distinct, approach of numerical stochastic perturbation theory.

  14. Preliminary Framework for Human-Automation Collaboration

    SciTech Connect

    Oxstrand, Johanna Helene; Le Blanc, Katya Lee; Spielman, Zachary Alexander

    2015-09-01

    The Department of Energy’s Advanced Reactor Technologies Program sponsors research, development and deployment activities through its Next Generation Nuclear Plant, Advanced Reactor Concepts, and Advanced Small Modular Reactor (aSMR) Programs to promote safety, technical, economical, and environmental advancements of innovative Generation IV nuclear energy technologies. The Human Automation Collaboration (HAC) Research Project is located under the aSMR Program, which identifies developing advanced instrumentation and controls and human-machine interfaces as one of four key research areas. It is expected that the new nuclear power plant designs will employ technology significantly more advanced than the analog systems in the existing reactor fleet as well as utilizing automation to a greater extent. Moving towards more advanced technology and more automation does not necessary imply more efficient and safer operation of the plant. Instead, a number of concerns about how these technologies will affect human performance and the overall safety of the plant need to be addressed. More specifically, it is important to investigate how the operator and the automation work as a team to ensure effective and safe plant operation, also known as the human-automation collaboration (HAC). The focus of the HAC research is to understand how various characteristics of automation (such as its reliability, processes, and modes) effect an operator’s use and awareness of plant conditions. In other words, the research team investigates how to best design the collaboration between the operators and the automated systems in a manner that has the greatest positive impact on overall plant performance and reliability. This report addresses the Department of Energy milestone M4AT-15IN2302054, Complete Preliminary Framework for Human-Automation Collaboration, by discussing the two phased development of a preliminary HAC framework. The framework developed in the first phase was used as the

  15. Metrology automation reliability

    NASA Astrophysics Data System (ADS)

    Chain, Elizabeth E.

    1996-09-01

    At Motorola's MOS-12 facility automated measurements on 200- mm diameter wafers proceed in a hands-off 'load-and-go' mode requiring only wafer loading, measurement recipe loading, and a 'run' command for processing. Upon completion of all sample measurements, the data is uploaded to the factory's data collection software system via a SECS II interface, eliminating the requirement of manual data entry. The scope of in-line measurement automation has been extended to the entire metrology scheme from job file generation to measurement and data collection. Data analysis and comparison to part specification limits is also carried out automatically. Successful integration of automated metrology into the factory measurement system requires that automated functions, such as autofocus and pattern recognition algorithms, display a high degree of reliability. In the 24- hour factory reliability data can be collected automatically on every part measured. This reliability data is then uploaded to the factory data collection software system at the same time as the measurement data. Analysis of the metrology reliability data permits improvements to be made as needed, and provides an accurate accounting of automation reliability. This reliability data has so far been collected for the CD-SEM (critical dimension scanning electron microscope) metrology tool, and examples are presented. This analysis method can be applied to such automated in-line measurements as CD, overlay, particle and film thickness measurements.

  16. Automated Groundwater Screening

    SciTech Connect

    Taylor, Glenn A.; Collard, Leonard, B.

    2005-10-31

    The Automated Intruder Analysis has been extended to include an Automated Ground Water Screening option. This option screens 825 radionuclides while rigorously applying the National Council on Radiation Protection (NCRP) methodology. An extension to that methodology is presented to give a more realistic screening factor for those radionuclides which have significant daughters. The extension has the promise of reducing the number of radionuclides which must be tracked by the customer. By combining the Automated Intruder Analysis with the Automated Groundwater Screening a consistent set of assumptions and databases is used. A method is proposed to eliminate trigger values by performing rigorous calculation of the screening factor thereby reducing the number of radionuclides sent to further analysis. Using the same problem definitions as in previous groundwater screenings, the automated groundwater screening found one additional nuclide, Ge-68, which failed the screening. It also found that 18 of the 57 radionuclides contained in NCRP Table 3.1 failed the screening. This report describes the automated groundwater screening computer application.

  17. Elements of EAF automation processes

    NASA Astrophysics Data System (ADS)

    Ioana, A.; Constantin, N.; Dragna, E. C.

    2017-01-01

    Our article presents elements of Electric Arc Furnace (EAF) automation. So, we present and analyze detailed two automation schemes: the scheme of electrical EAF automation system; the scheme of thermic EAF automation system. The application results of these scheme of automation consists in: the sensitive reduction of specific consummation of electrical energy of Electric Arc Furnace, increasing the productivity of Electric Arc Furnace, increase the quality of the developed steel, increasing the durability of the building elements of Electric Arc Furnace.

  18. Automated Critical Peak Pricing Field Tests: Program Descriptionand Results

    SciTech Connect

    Piette, Mary Ann; Watson, David; Motegi, Naoya; Kiliccote, Sila; Xu, Peng

    2006-04-06

    California utilities have been exploring the use of critical peak prices (CPP) to help reduce needle peaks in customer end-use loads. CPP is a form of price-responsive demand response (DR). Recent experience has shown that customers have limited knowledge of how to operate their facilities in order to reduce their electricity costs under CPP (Quantum 2004). While the lack of knowledge about how to develop and implement DR control strategies is a barrier to participation in DR programs like CPP, another barrier is the lack of automation of DR systems. During 2003 and 2004, the PIER Demand Response Research Center (DRRC) conducted a series of tests of fully automated electric demand response (Auto-DR) at 18 facilities. Overall, the average of the site-specific average coincident demand reductions was 8% from a variety of building types and facilities. Many electricity customers have suggested that automation will help them institutionalize their electric demand savings and improve their overall response and DR repeatability. This report focuses on and discusses the specific results of the Automated Critical Peak Pricing (Auto-CPP, a specific type of Auto-DR) tests that took place during 2005, which build on the automated demand response (Auto-DR) research conducted through PIER and the DRRC in 2003 and 2004. The long-term goal of this project is to understand the technical opportunities of automating demand response and to remove technical and market impediments to large-scale implementation of automated demand response (Auto-DR) in buildings and industry. A second goal of this research is to understand and identify best practices for DR strategies and opportunities. The specific objectives of the Automated Critical Peak Pricing test were as follows: (1) Demonstrate how an automated notification system for critical peak pricing can be used in large commercial facilities for demand response (DR). (2) Evaluate effectiveness of such a system. (3) Determine how customers

  19. Influence of Lossy Compressed DEM on Radiometric Correction for Land Cover Classification of Remote Sensing Images

    NASA Astrophysics Data System (ADS)

    Moré, G.; Pesquer, L.; Blanes, I.; Serra-Sagristà, J.; Pons, X.

    2012-12-01

    World coverage Digital Elevation Models (DEM) have progressively increased their spatial resolution (e.g., ETOPO, SRTM, or Aster GDEM) and, consequently, their storage requirements. On the other hand, lossy data compression facilitates accessing, sharing and transmitting large spatial datasets in environments with limited storage. However, since lossy compression modifies the original information, rigorous studies are needed to understand its effects and consequences. The present work analyzes the influence of DEM quality -modified by lossy compression-, on the radiometric correction of remote sensing imagery, and the eventual propagation of the uncertainty in the resulting land cover classification. Radiometric correction is usually composed of two parts: atmospheric correction and topographical correction. For topographical correction, DEM provides the altimetry information that allows modeling the incidence radiation on terrain surface (cast shadows, self shadows, etc). To quantify the effects of the DEM lossy compression on the radiometric correction, we use radiometrically corrected images for classification purposes, and compare the accuracy of two standard coding techniques for a wide range of compression ratios. The DEM has been obtained by resampling the DEM v.2 of Catalonia (ICC), originally having 15 m resolution, to the Landsat TM resolution. The Aster DEM has been used to fill the gaps beyond the administrative limits of Catalonia. The DEM has been lossy compressed with two coding standards at compression ratios 5:1, 10:1, 20:1, 100:1 and 200:1. The employed coding standards have been JPEG2000 and CCSDS-IDC; the former is an international ISO/ITU-T standard for almost any type of images, while the latter is a recommendation of the CCSDS consortium for mono-component remote sensing images. Both techniques are wavelet-based followed by an entropy-coding stage. Also, for large compression ratios, both techniques need a post processing for correctly

  20. Honeywell Modular Automation System Computer Software Documentation

    SciTech Connect

    STUBBS, A.M.

    2000-12-04

    The purpose of this Computer Software Document (CSWD) is to provide configuration control of the Honeywell Modular Automation System (MAS) in use at the Plutonium Finishing Plant (PFP). This CSWD describes hardware and PFP developed software for control of stabilization furnaces. The Honeywell software can generate configuration reports for the developed control software. These reports are described in the following section and are attached as addendum's. This plan applies to PFP Engineering Manager, Thermal Stabilization Cognizant Engineers, and the Shift Technical Advisors responsible for the Honeywell MAS software/hardware and administration of the Honeywell System.