Sample records for automated sample mounting

  1. RoboDiff: combining a sample changer and goniometer for highly automated macromolecular crystallography experiments

    PubMed Central

    Nurizzo, Didier; Bowler, Matthew W.; Caserotto, Hugo; Dobias, Fabien; Giraud, Thierry; Surr, John; Guichard, Nicolas; Papp, Gergely; Guijarro, Matias; Mueller-Dieckmann, Christoph; Flot, David; McSweeney, Sean; Cipriani, Florent; Theveneau, Pascal; Leonard, Gordon A.

    2016-01-01

    Automation of the mounting of cryocooled samples is now a feature of the majority of beamlines dedicated to macromolecular crystallography (MX). Robotic sample changers have been developed over many years, with the latest designs increasing capacity, reliability and speed. Here, the development of a new sample changer deployed at the ESRF beamline MASSIF-1 (ID30A-1), based on an industrial six-axis robot, is described. The device, named RoboDiff, includes a high-capacity dewar, acts as both a sample changer and a high-accuracy goniometer, and has been designed for completely unattended sample mounting and diffraction data collection. This aim has been achieved using a high level of diagnostics at all steps of the process from mounting and characterization to data collection. The RoboDiff has been in service on the fully automated endstation MASSIF-1 at the ESRF since September 2014 and, at the time of writing, has processed more than 20 000 samples completely automatically. PMID:27487827

  2. Automated Sample Exchange Robots for the Structural Biology Beam Lines at the Photon Factory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hiraki, Masahiko; Watanabe, Shokei; Yamada, Yusuke

    2007-01-19

    We are now developing automated sample exchange robots for high-throughput protein crystallographic experiments for onsite use at synchrotron beam lines. It is part of the fully automated robotics systems being developed at the Photon Factory, for the purposes of protein crystallization, monitoring crystal growth, harvesting and freezing crystals, mounting the crystals inside a hutch and for data collection. We have already installed the sample exchange robots based on the SSRL automated mounting system at our insertion device beam lines BL-5A and AR-NW12A at the Photon Factory. In order to reduce the time required for sample exchange further, a prototype ofmore » a double-tonged system was developed. As a result of preliminary experiments with double-tonged robots, the sample exchange time was successfully reduced from 70 seconds to 10 seconds with the exception of the time required for pre-cooling and warming up the tongs.« less

  3. Tensile film clamps and mounting block for the rheovibron and autovibron viscoelastometer

    NASA Technical Reports Server (NTRS)

    Stoakley, Diane M. (Inventor); St.clair, Anne K. (Inventor); Little, Bruce D. (Inventor)

    1989-01-01

    A set of film clamps and a mounting block for use in the determination of tensile modulus and damping properties of films in a manually operated or automated Rheovibron is diagrammed. These clamps and mounting block provide uniformity of sample gripping and alignment in the instrument. Operator dependence and data variability are greatly reduced.

  4. The Stanford Automated Mounter: Pushing the limits of sample exchange at the SSRL macromolecular crystallography beamlines

    DOE PAGES

    Russi, Silvia; Song, Jinhu; McPhillips, Scott E.; ...

    2016-02-24

    The Stanford Automated Mounter System, a system for mounting and dismounting cryo-cooled crystals, has been upgraded to increase the throughput of samples on the macromolecular crystallography beamlines at the Stanford Synchrotron Radiation Lightsource. This upgrade speeds up robot maneuvers, reduces the heating/drying cycles, pre-fetches samples and adds an air-knife to remove frost from the gripper arms. As a result, sample pin exchange during automated crystal quality screening now takes about 25 s, five times faster than before this upgrade.

  5. The Stanford Automated Mounter: Pushing the limits of sample exchange at the SSRL macromolecular crystallography beamlines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russi, Silvia; Song, Jinhu; McPhillips, Scott E.

    The Stanford Automated Mounter System, a system for mounting and dismounting cryo-cooled crystals, has been upgraded to increase the throughput of samples on the macromolecular crystallography beamlines at the Stanford Synchrotron Radiation Lightsource. This upgrade speeds up robot maneuvers, reduces the heating/drying cycles, pre-fetches samples and adds an air-knife to remove frost from the gripper arms. As a result, sample pin exchange during automated crystal quality screening now takes about 25 s, five times faster than before this upgrade.

  6. Tensil Film Clamps And Mounting Block For Viscoelastometers

    NASA Technical Reports Server (NTRS)

    Stoakley, Diane M.; St. Clair, Anne K.; Little, Bruce D.

    1989-01-01

    Set of clamps and mounting block developed for use in determining tensile moduli and damping properties of films in manually operated or automated commercial viscoelastometer. These clamps and block provide uniformity of sample gripping and alignment in instrument. Dependence on operator and variability of data greatly reduced.

  7. EPICS controlled sample mounting robots at the GM/CA CAT.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makarov, O. A.; Benn, R.; Corcoran, S.

    2007-11-11

    GM/CA CAT at Sector 23 of the advanced photon source (APS) is an NIH funded facility for crystallographic structure determination of biological macromolecules by X-ray diffraction [R.F. Fischetti, et al., GM/CA canted undulator beamlines for protein crystallography, Acta Crystallogr. A 61 (2005) C139]. The facility consists of three beamlines; two based on canted undulators and one on a bending magnet. The scientific and technical goals of the CAT emphasize streamlined, efficient throughput for a variety of sample types, sizes and qualities, representing the cutting edge of structural biology research. For this purpose all three beamlines are equipped with the ALS-stylemore » robots [C.W.Cork, et al. Status of the BCSB automated sample mounting and alignment system for macromolecular crystallography at the Advanced Light Source, SRI-2003, San-Francisco, CA, USA, August 25-29, 2003] for an automated mounting of cryo-protected macromolecular crystals. This report summarizes software and technical solutions implemented with the first of the three operational robots at beamline 23-ID-B. The automounter's Dewar can hold up to 72 or 96 samples residing in six Rigaku ACTOR magazines or ALS-style pucks, respectively. Mounting of a crystal takes approximately 2 s, during which time the temperature of the crystal is maintained near that of liquid nitrogen.« less

  8. Automated fluid analysis apparatus and techniques

    DOEpatents

    Szecsody, James E.

    2004-03-16

    An automated device that couples a pair of differently sized sample loops with a syringe pump and a source of degassed water. A fluid sample is mounted at an inlet port and delivered to the sample loops. A selected sample from the sample loops is diluted in the syringe pump with the degassed water and fed to a flow through detector for analysis. The sample inlet is also directly connected to the syringe pump to selectively perform analysis without dilution. The device is airtight and used to detect oxygen-sensitive species, such as dithionite in groundwater following a remedial injection to treat soil contamination.

  9. Turbidity threshold sampling for suspended sediment load estimation

    Treesearch

    Jack Lewis; Rand Eads

    2001-01-01

    Abstract - The paper discusses an automated procedure for measuring turbidity and sampling suspended sediment. The basic equipment consists of a programmable data logger, an in situ turbidimeter, a pumping sampler, and a stage-measuring device. The data logger program employs turbidity to govern sample collection during each transport event. Mounting configurations and...

  10. Nondestructive Evaluation of Metallized Tape Bonds Formed by Tape Automated Bonding (TAB)

    DTIC Science & Technology

    1989-04-01

    powered by micro-positioning linear actuators. 3) Interchangeable sample-holding fixtures mounted upon top of slide assembly. 4) Coverslip gantry mounted...Controller Unit 1) Motor power supplies 2) Motor output servo driver amplifiers 3) "Macro-language" command Interpreter 4) Two-way cormunications with...adjustments are manual knobs giving approximately one degree of tilt adjustment per turn. The servo controller has self-contained power supplies for

  11. Automated Mounting Bias Calibration for Airborne LIDAR System

    NASA Astrophysics Data System (ADS)

    Zhang, J.; Jiang, W.; Jiang, S.

    2012-07-01

    Mounting bias is the major error source of Airborne LIDAR system. In this paper, an automated calibration method for estimating LIDAR system mounting parameters is introduced. LIDAR direct geo-referencing model is used to calculate systematic errors. Due to LIDAR footprints discretely sampled, the real corresponding laser points are hardly existence among different strips. The traditional corresponding point methodology does not seem to apply to LIDAR strip registration. We proposed a Virtual Corresponding Point Model to resolve the corresponding problem among discrete laser points. Each VCPM contains a corresponding point and three real laser footprints. Two rules are defined to calculate tie point coordinate from real laser footprints. The Scale Invariant Feature Transform (SIFT) is used to extract corresponding points in LIDAR strips, and the automatic flow of LIDAR system calibration based on VCPM is detailed described. The practical examples illustrate the feasibility and effectiveness of the proposed calibration method.

  12. Automated SEM and TEM sample preparation applied to copper/low k materials

    NASA Astrophysics Data System (ADS)

    Reyes, R.; Shaapur, F.; Griffiths, D.; Diebold, A. C.; Foran, B.; Raz, E.

    2001-01-01

    We describe the use of automated microcleaving for preparation of both SEM and TEM samples as done by SELA's new MC500 and TEMstation tools. The MC500 is an automated microcleaving tool that is capable of producing cleaves with 0.25 μm accuracy resulting in SEM-ready samples. The TEMstation is capable of taking a sample output from the MC500 (or from SELA's earlier MC200 tool) and producing a FIB ready slice of 25±5 μm, mounted on a TEM-washer and ready for FIB thinning to electron transparency for TEM analysis. The materials selected for the tool set evaluation mainly included the Cu/TaN/HOSP low-k system. The paper is divided into three sections, experimental approach, SEM preparation and analysis of HOSP low-k, and TEM preparation and analysis of Cu/TaN/HOSP low-k samples. For the samples discussed, data is presented to show the quality of preparation provided by these new automated tools.

  13. High-density grids for efficient data collection from multiple crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baxter, Elizabeth L.; Aguila, Laura; Alonso-Mori, Roberto

    Higher throughput methods to mount and collect data from multiple small and radiation-sensitive crystals are important to support challenging structural investigations using microfocus synchrotron beamlines. Furthermore, efficient sample-delivery methods are essential to carry out productive femtosecond crystallography experiments at X-ray free-electron laser (XFEL) sources such as the Linac Coherent Light Source (LCLS). To address these needs, a high-density sample grid useful as a scaffold for both crystal growth and diffraction data collection has been developed and utilized for efficient goniometer-based sample delivery at synchrotron and XFEL sources. A single grid contains 75 mounting ports and fits inside an SSRL cassettemore » or uni-puck storage container. The use of grids with an SSRL cassette expands the cassette capacity up to 7200 samples. Grids may also be covered with a polymer film or sleeve for efficient room-temperature data collection from multiple samples. New automated routines have been incorporated into theBlu-Ice/DCSSexperimental control system to support grids, including semi-automated grid alignment, fully automated positioning of grid ports, rastering and automated data collection. Specialized tools have been developed to support crystallization experiments on grids, including a universal adaptor, which allows grids to be filled by commercial liquid-handling robots, as well as incubation chambers, which support vapor-diffusion and lipidic cubic phase crystallization experiments. Experiments in which crystals were loaded into grids or grown on grids using liquid-handling robots and incubation chambers are described. As a result, crystals were screened at LCLS-XPP and SSRL BL12-2 at room temperature and cryogenic temperatures.« less

  14. High-density grids for efficient data collection from multiple crystals

    PubMed Central

    Baxter, Elizabeth L.; Aguila, Laura; Alonso-Mori, Roberto; Barnes, Christopher O.; Bonagura, Christopher A.; Brehmer, Winnie; Brunger, Axel T.; Calero, Guillermo; Caradoc-Davies, Tom T.; Chatterjee, Ruchira; Degrado, William F.; Fraser, James S.; Ibrahim, Mohamed; Kern, Jan; Kobilka, Brian K.; Kruse, Andrew C.; Larsson, Karl M.; Lemke, Heinrik T.; Lyubimov, Artem Y.; Manglik, Aashish; McPhillips, Scott E.; Norgren, Erik; Pang, Siew S.; Soltis, S. M.; Song, Jinhu; Thomaston, Jessica; Tsai, Yingssu; Weis, William I.; Woldeyes, Rahel A.; Yachandra, Vittal; Yano, Junko; Zouni, Athina; Cohen, Aina E.

    2016-01-01

    Higher throughput methods to mount and collect data from multiple small and radiation-sensitive crystals are important to support challenging structural investigations using microfocus synchrotron beamlines. Furthermore, efficient sample-delivery methods are essential to carry out productive femtosecond crystallography experiments at X-ray free-electron laser (XFEL) sources such as the Linac Coherent Light Source (LCLS). To address these needs, a high-density sample grid useful as a scaffold for both crystal growth and diffraction data collection has been developed and utilized for efficient goniometer-based sample delivery at synchrotron and XFEL sources. A single grid contains 75 mounting ports and fits inside an SSRL cassette or uni-puck storage container. The use of grids with an SSRL cassette expands the cassette capacity up to 7200 samples. Grids may also be covered with a polymer film or sleeve for efficient room-temperature data collection from multiple samples. New automated routines have been incorporated into the Blu-Ice/DCSS experimental control system to support grids, including semi-automated grid alignment, fully automated positioning of grid ports, rastering and automated data collection. Specialized tools have been developed to support crystallization experiments on grids, including a universal adaptor, which allows grids to be filled by commercial liquid-handling robots, as well as incubation chambers, which support vapor-diffusion and lipidic cubic phase crystallization experiments. Experiments in which crystals were loaded into grids or grown on grids using liquid-handling robots and incubation chambers are described. Crystals were screened at LCLS-XPP and SSRL BL12-2 at room temperature and cryogenic temperatures. PMID:26894529

  15. High-density grids for efficient data collection from multiple crystals

    DOE PAGES

    Baxter, Elizabeth L.; Aguila, Laura; Alonso-Mori, Roberto; ...

    2015-11-03

    Higher throughput methods to mount and collect data from multiple small and radiation-sensitive crystals are important to support challenging structural investigations using microfocus synchrotron beamlines. Furthermore, efficient sample-delivery methods are essential to carry out productive femtosecond crystallography experiments at X-ray free-electron laser (XFEL) sources such as the Linac Coherent Light Source (LCLS). To address these needs, a high-density sample grid useful as a scaffold for both crystal growth and diffraction data collection has been developed and utilized for efficient goniometer-based sample delivery at synchrotron and XFEL sources. A single grid contains 75 mounting ports and fits inside an SSRL cassettemore » or uni-puck storage container. The use of grids with an SSRL cassette expands the cassette capacity up to 7200 samples. Grids may also be covered with a polymer film or sleeve for efficient room-temperature data collection from multiple samples. New automated routines have been incorporated into theBlu-Ice/DCSSexperimental control system to support grids, including semi-automated grid alignment, fully automated positioning of grid ports, rastering and automated data collection. Specialized tools have been developed to support crystallization experiments on grids, including a universal adaptor, which allows grids to be filled by commercial liquid-handling robots, as well as incubation chambers, which support vapor-diffusion and lipidic cubic phase crystallization experiments. Experiments in which crystals were loaded into grids or grown on grids using liquid-handling robots and incubation chambers are described. As a result, crystals were screened at LCLS-XPP and SSRL BL12-2 at room temperature and cryogenic temperatures.« less

  16. Current status and future prospects of an automated sample exchange system PAM for protein crystallography

    NASA Astrophysics Data System (ADS)

    Hiraki, M.; Yamada, Y.; Chavas, L. M. G.; Matsugaki, N.; Igarashi, N.; Wakatsuki, S.

    2013-03-01

    To achieve fully-automated and/or remote data collection in high-throughput X-ray experiments, the Structural Biology Research Centre at the Photon Factory (PF) has installed PF automated mounting system (PAM) for sample exchange robots at PF macromolecular crystallography beamlines BL-1A, BL-5A, BL-17A, AR-NW12A and AR-NE3A. We are upgrading the experimental systems, including the PAM for stable and efficient operation. To prevent human error in automated data collection, we installed a two-dimensional barcode reader for identification of the cassettes and sample pins. Because no liquid nitrogen pipeline in the PF experimental hutch is installed, the users commonly add liquid nitrogen using a small Dewar. To address this issue, an automated liquid nitrogen filling system that links a 100-liter tank to the robot Dewar has been installed on the PF macromolecular beamline. Here we describe this new implementation, as well as future prospects.

  17. Mass-spectrometric mining of Hadean zircons by automated SHRIMP multi-collector and single-collector U/Pb zircon age dating: The first 100,000 grains

    NASA Astrophysics Data System (ADS)

    Holden, Peter; Lanc, Peter; Ireland, Trevor R.; Harrison, T. Mark; Foster, John J.; Bruce, Zane

    2009-09-01

    The identification and retrieval of a large population of ancient zircons (>4 Ga; Hadean) is of utmost priority if models of the early evolution of Earth are to be rigorously tested. We have developed a rapid and accurate U-Pb zircon age determination protocol utilizing a fully automated multi-collector ion microprobe, the ANU SHRIMP II, to screen and date these zircons. Unattended data acquisition relies on the calibration of a digitized sample map to the Sensitive High Resolution Ion MicroProbe (SHRIMP) sample-stage co-ordinate system. High precision positioning of individual grains can be produced through optical image processing of a specified mount location. The focal position of the mount can be optimized through a correlation between secondary-ion steering and the spot position on the target. For the Hadean zircon project, sample mounts are photographed and sample locations (normally grain centers) are determined off-line. The sample is loaded, reference points calibrated, and the target positions are then visited sequentially. In SHRIMP II multiple-collector mode, zircons are initially screened (ca. 5 s data acquisition) through their 204Pb corrected 207Pb/206Pb ratio; suitable candidates are then analyzed in a longer routine to obtain better measurement statistics, U/Pb, and concentration data. In SHRIMP I and SHRIMP RG, we have incorporated the automated analysis protocol to single-collector measurements. These routines have been used to analyze over 100,000 zircons from the Jack Hills quartzite. Of these, ca. 7%, have an age greater than 3.8 Ga, the oldest grain being 4372 +/- 6 Ma (2[sigma]), and this age is part of a group of analyses around 4350 Ma which we interpret as the age when continental crust first began to coalesce in this region. In multi-collector mode, the analytical time taken for a single mount with 400 zircons is approximately 6 h; whereas in single-collector mode, the analytical time is ca. 17 h. With this productivity, we can produce significant numbers of zircons for statistically limited studies including correlations between age and morphology, mineral-inclusion paragenesis, as well as isotopic studies including Hf and O isotopic compositions, Pu-Xe, and Sm-Nd isotopes.

  18. Helmet-Mounted Display Of Clouds Of Harmful Gases

    NASA Technical Reports Server (NTRS)

    Diner, Daniel B.; Barengoltz, Jack B.; Schober, Wayne R.

    1995-01-01

    Proposed helmet-mounted opto-electronic instrument provides real-time stereoscopic views of clouds of otherwise invisible toxic, explosive, and/or corrosive gas. Display semitransparent: images of clouds superimposed on scene ordinarily visible to wearer. Images give indications on sizes and concentrations of gas clouds and their locations in relation to other objects in scene. Instruments serve as safety devices for astronauts, emergency response crews, fire fighters, people cleaning up chemical spills, or anyone working near invisible hazardous gases. Similar instruments used as sensors in automated emergency response systems that activate safety equipment and emergency procedures. Both helmet-mounted and automated-sensor versions used at industrial sites, chemical plants, or anywhere dangerous and invisible or difficult-to-see gases present. In addition to helmet-mounted and automated-sensor versions, there could be hand-held version. In some industrial applications, desirable to mount instruments and use them similarly to parking-lot surveillance cameras.

  19. High density grids

    DOEpatents

    Cohen, Aina E.; Baxter, Elizabeth L.

    2018-01-16

    An X-ray data collection grid device is provided that includes a magnetic base that is compatible with robotic sample mounting systems used at synchrotron beamlines, a grid element fixedly attached to the magnetic base, where the grid element includes at least one sealable sample window disposed through a planar synchrotron-compatible material, where the planar synchrotron-compatible material includes at least one automated X-ray positioning and fluid handling robot fiducial mark.

  20. Automated four color CD4/CD8 analysis of leukocytes by scanning fluorescence microscopy using Quantum dots

    NASA Astrophysics Data System (ADS)

    Bocsi, Jozsef; Mittag, Anja; Varga, Viktor S.; Molnar, Bela; Tulassay, Zsolt; Sack, Ulrich; Lenz, Dominik; Tarnok, Attila

    2006-02-01

    Scanning Fluorescence Microscope (SFM) is a new technique for automated motorized microscopes to measure multiple fluorochrome labeled cells (Bocsi et al. Cytometry 2004, 61A:1). The ratio of CD4+/CD8+ cells is an important in immune diagnostics in immunodeficiency and HIV. Therefor a four-color staining protocol (DNA, CD3, CD4 and CD8) for automated SFM analysis of lymphocytes was developed. EDTA uncoagulated blood was stained with organic and inorganic (Quantum dots) fluorochromes in different combinations. Aliquots of samples were measured by Flow Cytometry (FCM) and SFM. By SFM specimens were scanned and digitized using four fluorescence filter sets. Automated cell detection (based on Hoechst 33342 fluorescence), CD3, CD4 and CD8 detection were performed, CD4/CD8 ratio was calculated. Fluorescence signals were well separable on SFM and FCM. Passing and Bablok regression of all CD4/CD8 ratios obtained by FCM and SFM (F(X)=0.0577+0.9378x) are in the 95% confidence interval. Cusum test did not show significant deviation from linearity (P>0.10). This comparison indicates that there is no systemic bias between the two different methods. In SFM analyses the inorganic Quantum dot staining was very stable in PBS in contrast to the organic fluorescent dyes, but bleached shortly after mounting with antioxidant and free radical scavenger mounting media. This shows the difficulty of combinations of organic dyes and Quantum dots. Slide based multi-fluorescence labeling system and automated SFM are applicable tools for the CD4/CD8 ratio determination in peripheral blood samples. Quantum Dots are stable inorganic fluorescence labels that may be used as reliable high resolution dyes for cell labeling.

  1. Fully Automated Data Collection Using PAM and the Development of PAM/SPACE Reversible Cassettes

    NASA Astrophysics Data System (ADS)

    Hiraki, Masahiko; Watanabe, Shokei; Chavas, Leonard M. G.; Yamada, Yusuke; Matsugaki, Naohiro; Igarashi, Noriyuki; Wakatsuki, Soichi; Fujihashi, Masahiro; Miki, Kunio; Baba, Seiki; Ueno, Go; Yamamoto, Masaki; Suzuki, Mamoru; Nakagawa, Atsushi; Watanabe, Nobuhisa; Tanaka, Isao

    2010-06-01

    To remotely control and automatically collect data in high-throughput X-ray data collection experiments, the Structural Biology Research Center at the Photon Factory (PF) developed and installed sample exchange robots PAM (PF Automated Mounting system) at PF macromolecular crystallography beamlines; BL-5A, BL-17A, AR-NW12A and AR-NE3A. We developed and installed software that manages the flow of the automated X-ray experiments; sample exchanges, loop-centering and X-ray diffraction data collection. The fully automated data collection function has been available since February 2009. To identify sample cassettes, PAM employs a two-dimensional bar code reader. New beamlines, BL-1A at the Photon Factory and BL32XU at SPring-8, are currently under construction as part of Targeted Proteins Research Program (TPRP) by the Ministry of Education, Culture, Sports, Science and Technology of Japan. However, different robots, PAM and SPACE (SPring-8 Precise Automatic Cryo-sample Exchanger), will be installed at BL-1A and BL32XU, respectively. For the convenience of the users of both facilities, pins and cassettes for PAM and SPACE are developed as part of the TPRP.

  2. System Would Acquire Core and Powder Samples of Rocks

    NASA Technical Reports Server (NTRS)

    Bar-Cohen, Yoseph; Randolph, James; Bao, Xiaoqi; Sherrit, Stewart; Ritz, Chuck; Cook, Greg

    2006-01-01

    A system for automated sampling of rocks, ice, and similar hard materials at and immediately below the surface of the ground is undergoing development. The system, denoted a sample preparation, acquisition, handling, and delivery (SPAHD) device, would be mounted on a robotic exploratory vehicle that would traverse the terrain of interest on the Earth or on a remote planet. The SPAHD device would probe the ground to obtain data for optimization of sampling, prepare the surface, acquire samples in the form(s) of cores and/or powdered cuttings, and deliver the samples to a selected location for analysis and/or storage.

  3. Automated inspection of solder joints for surface mount technology

    NASA Technical Reports Server (NTRS)

    Savage, Robert M.; Park, Hyun Soo; Fan, Mark S.

    1993-01-01

    Researchers at NASA/GSFC evaluated various automated inspection systems (AIS) technologies using test boards with known defects in surface mount solder joints. These boards were complex and included almost every type of surface mount device typical of critical assemblies used for space flight applications: X-ray radiography; X-ray laminography; Ultrasonic Imaging; Optical Imaging; Laser Imaging; and Infrared Inspection. Vendors, representative of the different technologies, inspected the test boards with their particular machine. The results of the evaluation showed limitations of AIS. Furthermore, none of the AIS technologies evaluated proved to meet all of the inspection criteria for use in high-reliability applications. It was found that certain inspection systems could supplement but not replace manual inspection for low-volume, high-reliability, surface mount solder joints.

  4. Automated extraction of DNA from blood and PCR setup using a Tecan Freedom EVO liquid handler for forensic genetic STR typing of reference samples.

    PubMed

    Stangegaard, Michael; Frøslev, Tobias G; Frank-Hansen, Rune; Hansen, Anders J; Morling, Niels

    2011-04-01

    We have implemented and validated automated protocols for DNA extraction and PCR setup using a Tecan Freedom EVO liquid handler mounted with the Te-MagS magnetic separation device (Tecan, Männedorf, Switzerland). The protocols were validated for accredited forensic genetic work according to ISO 17025 using the Qiagen MagAttract DNA Mini M48 kit (Qiagen GmbH, Hilden, Germany) from fresh whole blood and blood from deceased individuals. The workflow was simplified by returning the DNA extracts to the original tubes minimizing the risk of misplacing samples. The tubes that originally contained the samples were washed with MilliQ water before the return of the DNA extracts. The PCR was setup in 96-well microtiter plates. The methods were validated for the kits: AmpFℓSTR Identifiler, SGM Plus and Yfiler (Applied Biosystems, Foster City, CA), GenePrint FFFL and PowerPlex Y (Promega, Madison, WI). The automated protocols allowed for extraction and addition of PCR master mix of 96 samples within 3.5h. In conclusion, we demonstrated that (1) DNA extraction with magnetic beads and (2) PCR setup for accredited, forensic genetic short tandem repeat typing can be implemented on a simple automated liquid handler leading to the reduction of manual work, and increased quality and throughput. Copyright © 2011 Society for Laboratory Automation and Screening. Published by Elsevier Inc. All rights reserved.

  5. Semi-automated high-efficiency reflectivity chamber for vacuum UV measurements

    NASA Astrophysics Data System (ADS)

    Wiley, James; Fleming, Brian; Renninger, Nicholas; Egan, Arika

    2017-08-01

    This paper presents the design and theory of operation for a semi-automated reflectivity chamber for ultraviolet optimized optics. A graphical user interface designed in LabVIEW controls the stages, interfaces with the detector system, takes semi-autonomous measurements, and monitors the system in case of error. Samples and an optical photodiode sit on an optics plate mounted to a rotation stage in the middle of the vacuum chamber. The optics plate rotates the samples and diode between an incident and reflected position to measure the absolute reflectivity of the samples at wavelengths limited by the monochromator operational bandpass of 70 nm to 550 nm. A collimating parabolic mirror on a fine steering tip-tilt motor enables beam steering for detector peak-ups. This chamber is designed to take measurements rapidly and with minimal oversight, increasing lab efficiency for high cadence and high accuracy vacuum UV reflectivity measurements.

  6. Automated Analysis Workstation

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Information from NASA Tech Briefs of work done at Langley Research Center and the Jet Propulsion Laboratory assisted DiaSys Corporation in manufacturing their first product, the R/S 2000. Since then, the R/S 2000 and R/S 2003 have followed. Recently, DiaSys released their fourth workstation, the FE-2, which automates the process of making and manipulating wet-mount preparation of fecal concentrates. The time needed to read the sample is decreased, permitting technologists to rapidly spot parasites, ova and cysts, sometimes carried in the lower intestinal tract of humans and animals. Employing the FE-2 is non-invasive, can be performed on an out-patient basis, and quickly provides confirmatory results.

  7. Automated biowaste sampling system feces monitoring system

    NASA Technical Reports Server (NTRS)

    Hunt, S. R.; Glanfield, E. J.

    1979-01-01

    The Feces Monitoring System (FMS) Program designed, fabricated, assembled and tested an engineering model waste collector system (WCS) to be used in support of life science and medical experiments related to Shuttle missions. The FMS design was patterned closely after the Shuttle WCS, including: interface provisions; mounting; configuration; and operating procedures. These similarities make it possible to eventually substitute an FMS for the Shuttle WCS of Orbiter. In addition, several advanced waste collection features, including the capability of real-time inertial fecal separation and fecal mass measurement and sampling were incorporated into the FMS design.

  8. Automated edge finishing using an active XY table

    DOEpatents

    Loucks, Clifford S.; Starr, Gregory P.

    1993-01-01

    The disclosure is directed to an apparatus and method for automated edge finishing using hybrid position/force control of an XY table. The disclosure is particularly directed to learning the trajectory of the edge of a workpiece by "guarded moves". Machining is done by controllably moving the XY table, with the workpiece mounted thereon, along the learned trajectory with feedback from a force sensor. Other similar workpieces can be mounted, without a fixture on the XY table, located and the learned trajectory adjusted

  9. An automated in vitro model for the evaluation of ultrasound modalities measuring myocardial deformation

    PubMed Central

    2010-01-01

    Background Echocardiography is the method of choice when one wishes to examine myocardial function. Qualitative assessment of the 2D grey scale images obtained is subjective, and objective methods are required. Speckle Tracking Ultrasound is an emerging technology, offering an objective mean of quantifying left ventricular wall motion. However, before a new ultrasound technology can be adopted in the clinic, accuracy and reproducibility needs to be investigated. Aim It was hypothesized that the collection of ultrasound sample data from an in vitro model could be automated. The aim was to optimize an in vitro model to allow for efficient collection of sample data. Material & Methods A tissue-mimicking phantom was made from water, gelatin powder, psyllium fibers and a preservative. Sonomicrometry crystals were molded into the phantom. The solid phantom was mounted in a stable stand and cyclically compressed. Peak strain was then measured by Speckle Tracking Ultrasound and sonomicrometry. Results We succeeded in automating the acquisition and analysis of sample data. Sample data was collected at a rate of 200 measurement pairs in 30 minutes. We found good agreement between Speckle Tracking Ultrasound and sonomicrometry in the in vitro model. Best agreement was 0.83 ± 0.70%. Worst agreement was -1.13 ± 6.46%. Conclusions It has been shown possible to automate a model that can be used for evaluating the in vitro accuracy and precision of ultrasound modalities measuring deformation. Sonomicrometry and Speckle Tracking Ultrasound had acceptable agreement. PMID:20822532

  10. Measurement of surface microtopography

    NASA Technical Reports Server (NTRS)

    Wall, S. D.; Farr, T. G.; Muller, J.-P.; Lewis, P.; Leberl, F. W.

    1991-01-01

    Acquisition of ground truth data for use in microwave interaction modeling requires measurement of surface roughness sampled at intervals comparable to a fraction of the microwave wavelength and extensive enough to adequately represent the statistics of a surface unit. Sub-centimetric measurement accuracy is thus required over large areas, and existing techniques are usually inadequate. A technique is discussed for acquiring the necessary photogrammetric data using twin film cameras mounted on a helicopter. In an attempt to eliminate tedious data reduction, an automated technique was applied to the helicopter photographs, and results were compared to those produced by conventional stereogrammetry. Derived root-mean-square (RMS) roughness for the same stereo-pair was 7.5 cm for the automated technique versus 6.5 cm for the manual method. The principal source of error is probably due to vegetation in the scene, which affects the automated technique but is ignored by a human operator.

  11. Competition for DNA binding sites using Promega DNA IQ™ paramagnetic beads.

    PubMed

    Frégeau, Chantal J; De Moors, Anick

    2012-09-01

    The Promega DNA IQ™ system is easily amenable to automation and has been an integral part of standard operating procedures for many forensic laboratories including those of the Royal Canadian Mounted Police (RCMP) since 2004. Due to some failure to extract DNA from samples that should have produced DNA using our validated automated DNA IQ™-based protocol, the competition for binding sites on the DNA IQ™ magnetic beads was more closely examined. Heme from heavily blooded samples interfered slightly with DNA binding. Increasing the concentration of Proteinase K during lysis of these samples did not enhance DNA recovery. However, diluting the sample lysate following lysis prior to DNA extraction overcame the reduction in DNA yield and preserved portions of the lysates for subsequent manual or automated extraction. Dye/chemicals from black denim lysates competed for binding sites on the DNA IQ™ beads and significantly reduced DNA recovery. Increasing the size or number of black denim cuttings during lysis had a direct adverse effect on DNA yield from various blood volumes. The dilution approach was successful on these samples and permitted the extraction of high DNA yields. Alternatively, shortening the incubation time for cell lysis to 30 min instead of the usual overnight at 56 °C prevented competition from black denim dye/chemicals and increased DNA yields. Crown Copyright © 2011. Published by Elsevier Ireland Ltd. All rights reserved.

  12. Automated data collection equipment for monitoring highway condition.

    DOT National Transportation Integrated Search

    2005-06-01

    This study was conducted to evaluate automated vehicle mounted equipment to collect data on the needs of : Oregons highway inventory. Four vendors accepted invitations to evaluate their equipment. Although ODOT had : conducted a similar evaluation...

  13. An Automated Platform for High-Resolution Tissue Imaging Using Nanospray Desorption Electrospray Ionization Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lanekoff, Ingela T.; Heath, Brandi S.; Liyu, Andrey V.

    2012-10-02

    An automated platform has been developed for acquisition and visualization of mass spectrometry imaging (MSI) data using nanospray desorption electrospray ionization (nano-DESI). The new system enables robust operation of the nano-DESI imaging source over many hours. This is achieved by controlling the distance between the sample and the probe by mounting the sample holder onto an automated XYZ stage and defining the tilt of the sample plane. This approach is useful for imaging of relatively flat samples such as thin tissue sections. Custom software called MSI QuickView was developed for visualization of large data sets generated in imaging experiments. MSImore » QuickView enables fast visualization of the imaging data during data acquisition and detailed processing after the entire image is acquired. The performance of the system is demonstrated by imaging rat brain tissue sections. High resolution mass analysis combined with MS/MS experiments enabled identification of lipids and metabolites in the tissue section. In addition, high dynamic range and sensitivity of the technique allowed us to generate ion images of low-abundance isobaric lipids. High-spatial resolution image acquired over a small region of the tissue section revealed the spatial distribution of an abundant brain metabolite, creatine, in the white and gray matter that is consistent with the literature data obtained using magnetic resonance spectroscopy.« less

  14. Automated pinhole-aperture diagnostic for the current profiling of TWT electron beams

    NASA Astrophysics Data System (ADS)

    Wei, Yu-Xiang; Huang, Ming-Guang; Liu, Shu-Qing; Liu, Jin-Yue; Hao, Bao-Liang; Du, Chao-Hai; Liu, Pu-Kun

    2013-02-01

    The measurement system reported here is intended for use in determining the current density distribution of electron beams from Pierce guns for use in TWTs. The system was designed to automatically scan the cross section of the electron beam and collect the high-resolution data with a Faraday cup probe mounted on a multistage manipulator using the LabVIEW program. A 0.06 mm thick molybdenum plate with a pinhole and a Faraday cup mounted as a probe assembly was employed to sample the electron beam current with 0.5 µm space resolution. The thermal analysis of the probe with pulse beam heating was discussed. A 0.45 µP electron gun with the expected minimum beam radius 0.42 mm was measured and the three-dimensional current density distribution, beam envelope and phase space were presented.

  15. Center pivot mounted infrared sensors: Retrieval of ET and interface with satellite systems

    USDA-ARS?s Scientific Manuscript database

    Infrared sensors mounted aboard cener pivot irrigation systems can remotely sense the surface temperatures of the crops and soils, which provides important information on crop water status. This can be used for irrigation management and irrigation automation, which can increase crop water productivi...

  16. High-speed autoverifying technology for printed wiring boards

    NASA Astrophysics Data System (ADS)

    Ando, Moritoshi; Oka, Hiroshi; Okada, Hideo; Sakashita, Yorihiro; Shibutani, Nobumi

    1996-10-01

    We have developed an automated pattern verification technique. The output of an automated optical inspection system contains many false alarms. Verification is needed to distinguish between minor irregularities and serious defects. In the past, this verification was usually done manually, which led to unsatisfactory product quality. The goal of our new automated verification system is to detect pattern features on surface mount technology boards. In our system, we employ a new illumination method, which uses multiple colors and multiple direction illumination. Images are captured with a CCD camera. We have developed a new algorithm that uses CAD data for both pattern matching and pattern structure determination. This helps to search for patterns around a defect and to examine defect definition rules. These are processed with a high speed workstation and a hard-wired circuits. The system can verify a defect within 1.5 seconds. The verification system was tested in a factory. It verified 1,500 defective samples and detected all significant defects with only a 0.1 percent of error rate (false alarm).

  17. A new highly automated sputter equipment for in situ investigation of deposition processes with synchrotron radiation.

    PubMed

    Döhrmann, Ralph; Botta, Stephan; Buffet, Adeline; Santoro, Gonzalo; Schlage, Kai; Schwartzkopf, Matthias; Bommel, Sebastian; Risch, Johannes F H; Mannweiler, Roman; Brunner, Simon; Metwalli, Ezzeldin; Müller-Buschbaum, Peter; Roth, Stephan V

    2013-04-01

    HASE (Highly Automated Sputter Equipment) is a new mobile setup developed to investigate deposition processes with synchrotron radiation. HASE is based on an ultra-high vacuum sputter deposition chamber equipped with an in-vacuum sample pick-and-place robot. This enables a fast and reliable sample change without breaking the vacuum conditions and helps to save valuable measurement time, which is required for experiments at synchrotron sources like PETRA III at DESY. An advantageous arrangement of several sputter guns, mounted on a rotative flange, gives the possibility to sputter under different deposition angles or to sputter different materials on the same substrate. The chamber is also equipped with a modular sample stage, which allows for the integration of different sample environments, such as a sample heating and cooling device. The design of HASE is unique in the flexibility. The combination of several different sputtering methods like standard deposition, glancing angle deposition, and high pressure sputter deposition combined with heating and cooling possibilities of the sample, the large exit windows, and the degree of automation facilitate many different grazing incidence X-ray scattering experiments, such as grazing incidence small and wide angle X-ray scattering, in one setup. In this paper we describe in detail the design and the performance of the new equipment and present the installation of the HASE apparatus at the Micro and Nano focus X-ray Scattering beamline (MiNaXS) at PETRA III. Furthermore, we describe the measurement options and present some selected results. The HASE setup has been successfully commissioned and is now available for users.

  18. A new highly automated sputter equipment for in situ investigation of deposition processes with synchrotron radiation

    NASA Astrophysics Data System (ADS)

    Döhrmann, Ralph; Botta, Stephan; Buffet, Adeline; Santoro, Gonzalo; Schlage, Kai; Schwartzkopf, Matthias; Bommel, Sebastian; Risch, Johannes F. H.; Mannweiler, Roman; Brunner, Simon; Metwalli, Ezzeldin; Müller-Buschbaum, Peter; Roth, Stephan V.

    2013-04-01

    HASE (Highly Automated Sputter Equipment) is a new mobile setup developed to investigate deposition processes with synchrotron radiation. HASE is based on an ultra-high vacuum sputter deposition chamber equipped with an in-vacuum sample pick-and-place robot. This enables a fast and reliable sample change without breaking the vacuum conditions and helps to save valuable measurement time, which is required for experiments at synchrotron sources like PETRA III at DESY. An advantageous arrangement of several sputter guns, mounted on a rotative flange, gives the possibility to sputter under different deposition angles or to sputter different materials on the same substrate. The chamber is also equipped with a modular sample stage, which allows for the integration of different sample environments, such as a sample heating and cooling device. The design of HASE is unique in the flexibility. The combination of several different sputtering methods like standard deposition, glancing angle deposition, and high pressure sputter deposition combined with heating and cooling possibil-ities of the sample, the large exit windows, and the degree of automation facilitate many different grazing incidence X-ray scattering experiments, such as grazing incidence small and wide angle X-ray scattering, in one setup. In this paper we describe in detail the design and the performance of the new equipment and present the installation of the HASE apparatus at the Micro and Nano focus X-ray Scattering beamline (MiNaXS) at PETRA III. Furthermore, we describe the measurement options and present some selected results. The HASE setup has been successfully commissioned and is now available for users.

  19. BioSAXS Sample Changer: a robotic sample changer for rapid and reliable high-throughput X-ray solution scattering experiments

    PubMed Central

    Round, Adam; Felisaz, Franck; Fodinger, Lukas; Gobbo, Alexandre; Huet, Julien; Villard, Cyril; Blanchet, Clement E.; Pernot, Petra; McSweeney, Sean; Roessle, Manfred; Svergun, Dmitri I.; Cipriani, Florent

    2015-01-01

    Small-angle X-ray scattering (SAXS) of macromolecules in solution is in increasing demand by an ever more diverse research community, both academic and industrial. To better serve user needs, and to allow automated and high-throughput operation, a sample changer (BioSAXS Sample Changer) that is able to perform unattended measurements of up to several hundred samples per day has been developed. The Sample Changer is able to handle and expose sample volumes of down to 5 µl with a measurement/cleaning cycle of under 1 min. The samples are stored in standard 96-well plates and the data are collected in a vacuum-mounted capillary with automated positioning of the solution in the X-ray beam. Fast and efficient capillary cleaning avoids cross-contamination and ensures reproducibility of the measurements. Independent temperature control for the well storage and for the measurement capillary allows the samples to be kept cool while still collecting data at physiological temperatures. The Sample Changer has been installed at three major third-generation synchrotrons: on the BM29 beamline at the European Synchrotron Radiation Facility (ESRF), the P12 beamline at the PETRA-III synchrotron (EMBL@PETRA-III) and the I22/B21 beamlines at Diamond Light Source, with the latter being the first commercial unit supplied by Bruker ASC. PMID:25615861

  20. Development of sample exchange robot PAM-HC for beamline BL-1A at the photon factory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hiraki, Masahiko, E-mail: masahiko.hiraki@kek.jp; Department of Accelerator Science, SOKENDAI; Matsugaki, Naohiro

    A macromolecular crystallography beamline, BL-1A, has been built at the Photon Factory (PF) for low energy experiments and has been operational since 2010. We have installed a sample exchange robot, PAM (PF Automated Mounting system), similar to other macromolecular crystallography beamlines. However, following the installation of a helium chamber to reduce the absorption of the diffraction signal by air, we developed a new sample exchange robot to replace PAM. The new robot, named PAM-HC (Helium Chamber), is designed with the goal of minimizing leakage of helium gas from the chamber. Here, the PAM-HC hardware and the flow of its movementmore » are described. Furthermore, measurements of temperature changes during sample exchange are presented in this paper.« less

  1. Cognitive performance deficits in a simulated climb of Mount Everest - Operation Everest II

    NASA Technical Reports Server (NTRS)

    Kennedy, R. S.; Dunlap, W. P.; Banderet, L. E.; Smith, M. G.; Houston, C. S.

    1989-01-01

    Cognitive function at simulated altitude was investigated in a repeated-measures within-subject study of performance by seven volunteers in a hypobaric chamber, in which atmospheric pressure was systematically lowered over a period of 40 d to finally reach a pressure equivalent to 8845 m, the approximate height of Mount Everest. The automated performance test system employed compact computer design; automated test administrations, data storage, and retrieval; psychometric properties of stability and reliability; and factorial richness. Significant impairments of cognitive function were seen for three of the five tests in the battery; on two tests, grammatical reasoning and pattern comparison, every subject showed a substantial decrement.

  2. The Stanford Automated Mounter: Enabling High-Throughput Protein Crystal Screening at SSRL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, C.A.; Cohen, A.E.

    2009-05-26

    The macromolecular crystallography experiment lends itself perfectly to high-throughput technologies. The initial steps including the expression, purification, and crystallization of protein crystals, along with some of the later steps involving data processing and structure determination have all been automated to the point where some of the last remaining bottlenecks in the process have been crystal mounting, crystal screening, and data collection. At the Stanford Synchrotron Radiation Laboratory, a National User Facility that provides extremely brilliant X-ray photon beams for use in materials science, environmental science, and structural biology research, the incorporation of advanced robotics has enabled crystals to be screenedmore » in a true high-throughput fashion, thus dramatically accelerating the final steps. Up to 288 frozen crystals can be mounted by the beamline robot (the Stanford Auto-Mounting System) and screened for diffraction quality in a matter of hours without intervention. The best quality crystals can then be remounted for the collection of complete X-ray diffraction data sets. Furthermore, the entire screening and data collection experiment can be controlled from the experimenter's home laboratory by means of advanced software tools that enable network-based control of the highly automated beamlines.« less

  3. Automate Your Physical Plant Using the Building Block Approach.

    ERIC Educational Resources Information Center

    Michaelson, Matt

    1998-01-01

    Illustrates how Mount Saint Vincent University (Halifax), by upgrading the control and monitoring of one building or section of the school at a time, could produce savings in energy and operating costs and improve the environment. Explains a gradual, "building block" approach to facility automation that provides flexibility without a…

  4. How crawler track-mounted conveyors improve bulk handling's economics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hawkins, G.P.

    1984-11-01

    Crawler track-mounted conveyors can be used in most applications formerly requiring stacking, reclaiming or movement from excavators to bench conveyors. The crawler track-mounted conveyor has been automated for push button operation and allows mobilization of in-pit operations for the movement of overburden, minerals and coal. In-pit mobilization of crushers, the use of mobilized steep angle conveyor for the removal of coal from the pit, and the movement of overburden from excavation to spoil can all be done more economically when a combination of a crawler track mounted conveyor is used in conjunction with a shiftable or fixed conveyor.

  5. Design of an automated cart and mount for a hyperspectral imaging system to be used in produce fields

    USDA-ARS?s Scientific Manuscript database

    The goal of this project was to construct a cart and a mounting system that would allow a hyperspectral laser-induced fluorescence imaging system (HLIFIS) to be used to detect fecal material in produce fields. Fecal contaminated produce is a recognized food safety risk. Previous research demonstrate...

  6. Crew-integration and Automation Testbed (CAT)Program Overview and RUX06 Introduction

    DTIC Science & Technology

    2006-09-20

    unlimited Crew-integration and Automation Testbed ( CAT ) Program Overview and RUX06 Introduction 26-27 July 2006 Patrick Nunez, Terry Tierney, Brian Novak...3. DATES COVERED 4. TITLE AND SUBTITLE Crew-integration and Automation Testbed ( CAT )Program Overview and RUX06 Introduction 5a. CONTRACT...Experiment • Capstone CAT experiment – Evaluate effectiveness of CAT program in improving the performance and/or reducing the workload for a mounted

  7. The Mount Wilson optical interferometer: The first automated instrument and the prospects for lunar interferometry

    NASA Technical Reports Server (NTRS)

    Johnston, Ken J.; Mozurkewich, D.; Simon, R. S.; Shao, Michael; Colavita, M.

    1992-01-01

    Before contemplating an optical interferometer on the Moon one must first review the accomplishments achieved by this technology in scientific applications for astronomy. This will be done by presenting the technical status of optical interferometry as achieved by the Mount Wilson Optical Interferometer. The further developments needed for a future lunar-based interferometer are discussed.

  8. Automated detection of sperm whale sounds as a function of abrupt changes in sound intensity

    NASA Astrophysics Data System (ADS)

    Walker, Christopher D.; Rayborn, Grayson H.; Brack, Benjamin A.; Kuczaj, Stan A.; Paulos, Robin L.

    2003-04-01

    An algorithm designed to detect abrupt changes in sound intensity was developed and used to identify and count sperm whale vocalizations and to measure boat noise. The algorithm is a MATLAB routine that counts the number of occurrences for which the change in intensity level exceeds a threshold. The algorithm also permits the setting of a ``dead time'' interval to prevent the counting of multiple pulses within a single sperm whale click. This algorithm was used to analyze digitally sampled recordings of ambient noise obtained from the Gulf of Mexico using near bottom mounted EARS buoys deployed as part of the Littoral Acoustic Demonstration Center experiment. Because the background in these data varied slowly, the result of the application of the algorithm was automated detection of sperm whale clicks and creaks with results that agreed well with those obtained by trained human listeners. [Research supported by ONR.

  9. An interactive modular design for computerized photometry in spectrochemical analysis

    NASA Technical Reports Server (NTRS)

    Bair, V. L.

    1980-01-01

    A general functional description of totally automatic photometry of emission spectra is not available for an operating environment in which the sample compositions and analysis procedures are low-volume and non-routine. The advantages of using an interactive approach to computer control in such an operating environment are demonstrated. This approach includes modular subroutines selected at multiple-option, menu-style decision points. This style of programming is used to trace elemental determinations, including the automated reading of spectrographic plates produced by a 3.4 m Ebert mount spectrograph using a dc-arc in an argon atmosphere. The simplified control logic and modular subroutine approach facilitates innovative research and program development, yet is easily adapted to routine tasks. Operator confidence and control are increased by the built-in options including degree of automation, amount of intermediate data printed out, amount of user prompting, and multidirectional decision points.

  10. A simple on-line arterial time-activity curve detector for [O-15] water PET studies

    NASA Astrophysics Data System (ADS)

    Wollenweber, S. D.; Hichwa, R. D.; Ponto, L. L. B.

    1997-08-01

    A simple, automated on-line detector system has been fabricated and implemented to detect the arterial time-activity curve (TAG) for bolus-injection [O-15] water PET studies. This system offers two significant improvements over existing systems: a pump mechanism is not required to control arterial blood flow through the detector and dispersion correction of the time-activity curve for dispersion in external tubing is unnecessary. The [O-15] positrons emanating from blood within a thin-walled, 0.134 cm inner-diameter plastic tube are detected by a 0.5 cm wide by 1.0 cm long by 0.1 cm thick plastic scintillator mounted to a miniature PMT. Photon background is reduced to insignificant levels by a 2.0 cm thick cylindrical lead shield. Mean cerebral blood flow (mCBF) determined from an autoradiographic model and from the TAC measured by 1-second automated sampling was compared to that calculated from a TAC acquired using 5-second integrated manual samples. Improvements in timing resolution (1-sec vs. 5-sec) cause small but significant differences between the two sampling methods. Dispersion is minimized due to small tubing diameters, short lengths of tubing between the radial arterial sampling site and the detector and the presence of a 3-way valve 10 cm proximal to the detector.

  11. Automated robotic equipment for ultrasonic inspection of pressurizer heater wells

    DOEpatents

    Nachbar, Henry D.; DeRossi, Raymond S.; Mullins, Lawrence E.

    1993-01-01

    A robotic device for remotely inspecting pressurizer heater wells is provided which has the advantages of quickly, precisely, and reliably acquiring data at reasonable cost while also reducing radiation exposure of an operator. The device comprises a prober assembly including a probe which enters a heater well, gathers data regarding the condition of the heater well and transmits a signal carrying that data; a mounting device for mounting the probe assembly at the opening of the heater well so that the probe can enter the heater well; a first motor mounted on the mounting device for providing movement of the probe assembly in an axial direction; and a second motor mounted on the mounting device for providing rotation of the probe assembly. This arrangement enables full inspection of the heater well to be carried out.

  12. Inspection apparatus for evaluating a partially completed weld

    DOEpatents

    Smartt, Herschel B.; Larsen, Eric D.; Johnson, Jonn A.

    2001-01-01

    An inspection apparatus for evaluating a partially completed weld is described and which is utilized in combination with an automated movable welder which moves across a supporting surface, and wherein the inspection apparatus includes a coupling member mounted on the welder; a frame member mounted on the coupling member; an ultrasonic sensor mounted on the frame member and disposed in ultrasonic sound transmitting relation relative to the partially completed weld; and a drive assembly for adjusting the position of the ultrasonic sensor relative to the partially completed weld.

  13. An improved loopless mounting method for cryocrystallography

    NASA Astrophysics Data System (ADS)

    Qi, Jian-Xun; Jiang, Fan

    2010-01-01

    Based on a recent loopless mounting method, a simplified loopless and bufferless crystal mounting method is developed for macromolecular crystallography. This simplified crystal mounting system is composed of the following components: a home-made glass capillary, a brass seat for holding the glass capillary, a flow regulator, and a vacuum pump for evacuation. Compared with the currently prevalent loop mounting method, this simplified method has almost the same mounting procedure and thus is compatible with the current automated crystal mounting system. The advantages of this method include higher signal-to-noise ratio, more accurate measurement, more rapid flash cooling, less x-ray absorption and thus less radiation damage to the crystal. This method can be extended to the flash-freeing of a crystal without or with soaking it in a lower concentration of cryoprotectant, thus it may be the best option for data collection in the absence of suitable cryoprotectant. Therefore, it is suggested that this mounting method should be further improved and extensively applied to cryocrystallographic experiments.

  14. Automated exterior inspection of an aircraft with a pan-tilt-zoom camera mounted on a mobile robot

    NASA Astrophysics Data System (ADS)

    Jovančević, Igor; Larnier, Stanislas; Orteu, Jean-José; Sentenac, Thierry

    2015-11-01

    This paper deals with an automated preflight aircraft inspection using a pan-tilt-zoom camera mounted on a mobile robot moving autonomously around the aircraft. The general topic is image processing framework for detection and exterior inspection of different types of items, such as closed or unlatched door, mechanical defect on the engine, the integrity of the empennage, or damage caused by impacts or cracks. The detection step allows to focus on the regions of interest and point the camera toward the item to be checked. It is based on the detection of regular shapes, such as rounded corner rectangles, circles, and ellipses. The inspection task relies on clues, such as uniformity of isolated image regions, convexity of segmented shapes, and periodicity of the image intensity signal. The approach is applied to the inspection of four items of Airbus A320: oxygen bay handle, air-inlet vent, static ports, and fan blades. The results are promising and demonstrate the feasibility of an automated exterior inspection.

  15. Apparatus for the concurrent ultrasonic inspection of partially completed welds

    DOEpatents

    Johnson, John A.

    2000-01-01

    An apparatus for the concurrent nondestructive evaluation of partially completed welds is described and which is used in combination with an automated welder and which includes an ultrasonic signal generator mounted on the welder and which generates an ultrasonic signal which is directed toward one side of the partially completed welds; an ultrasonic signal receiver mounted on the automated welder for detecting ultrasonic signals which are transmitted by the ultrasonic signal generator and which are reflected or diffracted from one side of the partially completed weld or which passes through a given region of the partially completed weld; and an analysis assembly coupled with the ultrasonic signal receiver and which processes the ultrasonic signals received by the ultrasonic signal receiver to identify welding flaws in the partially completed weld.

  16. New Insights into the Composition and Texture of Lunar Regolith Using Ultrafast Automated Electron-Beam Analysis

    NASA Technical Reports Server (NTRS)

    Rickman, Doug; Wentworth, Susan J.; Schrader, Christian M.; Stoeser, Doug; Botha, Pieter WSK; Butcher, Alan R.; Horsch, Hanna E.; Benedictus, Aukje; Gottlieb, Paul; McKay, David

    2008-01-01

    Sieved grain mounts of Apollo 16 drive tube samples have been examined using QEMSCAN - an innovative electron beam technology. By combining multiple energy-dispersive X-ray detectors, fully automated control, and off-line image processing, to produce digital mineral maps of particles exposed on polished surfaces, the result is an unprecedented quantity of mineralogical and petrographic data, on a particle-by-particle basis. Experimental analysis of four size fractions (500-250 microns, 150-90 microns, 75-45 microns and < 20 microns), prepared from two samples (64002,374 and 64002,262), has produced a robust and uniform dataset which allows for the quantification of mineralogy; texture; particle shape, size and density; and the digital classification of distinct particle types in each measured sample. These preliminary data show that there is a decrease in plagioclase modal content and an opposing increase in glass modal content, with decreasing particle size. These findings, together with data on trace phases (metals, sulphides, phosphates, and oxides), provide not only new insights into the make-up of lunar regolith at the Apollo 16 landing site, but also key physical parameters which can be used to design lunar simulants, and compute Figures of Merit for each material produced.

  17. Triangulation methods for automated docking

    NASA Technical Reports Server (NTRS)

    Bales, John W.

    1996-01-01

    An automated docking system must have a reliable method for determining range and orientation of the passive (target) vehicle with respect to the active vehicle. This method must also provide accurate information on the rates of change of range to and orientation of the passive vehicle. The method must be accurate within required tolerances and capable of operating in real time. The method being developed at Marshall Space Flight Center employs a single TV camera, a laser illumination system and a target consisting, in its minimal configuration, of three retro-reflectors. Two of the retro-reflectors are mounted flush to the same surface, with the third retro-reflector mounted to a post fixed midway between the other two and jutting at a right angle from the surface. For redundancy, two additional retroreflectors are mounted on the surface on a line at right angles to the line containing the first two retro-reflectors, and equally spaced on either side of the post. The target vehicle will contain a large target for initial acquisition and several smaller targets for close range.

  18. Mounting Thin Samples For Electrical Measurements

    NASA Technical Reports Server (NTRS)

    Matus, L. G.; Summers, R. L.

    1988-01-01

    New method for mounting thin sample for electrical measurements involves use of vacuum chuck to hold a ceramic mounting plate, which holds sample. Contacts on mounting plate establish electrical connection to sample. Used to make electrical measurements over temperature range from 77 to 1,000 K and does not introduce distortions into magnetic field during Hall measurements.

  19. Note: Automated electrochemical etching and polishing of silver scanning tunneling microscope tips.

    PubMed

    Sasaki, Stephen S; Perdue, Shawn M; Rodriguez Perez, Alejandro; Tallarida, Nicholas; Majors, Julia H; Apkarian, V Ara; Lee, Joonhee

    2013-09-01

    Fabrication of sharp and smooth Ag tips is crucial in optical scanning probe microscope experiments. To ensure reproducible tip profiles, the polishing process is fully automated using a closed-loop laminar flow system to deliver the electrolytic solution to moving electrodes mounted on a motorized translational stage. The repetitive translational motion is controlled precisely on the μm scale with a stepper motor and screw-thread mechanism. The automated setup allows reproducible control over the tip profile and improves smoothness and sharpness of tips (radius 27 ± 18 nm), as measured by ultrafast field emission.

  20. The Design of the Automated Serials Accession System at the Library of the Mount Sinai School of Medicine of the City University of New York *

    PubMed Central

    Lemkau, Henry L.; Straub, John R.

    1970-01-01

    This paper describes the development of the Automated Serials Accession System. It demonstrates the logic used in the design of the mechanized system and how the problems encountered were handled. The areas of cooperation with the Medical Library Center of New York and the types of programs needed to run the system are explained. PMID:5439906

  1. An automated system for rail transit infrastructure inspection.

    DOT National Transportation Integrated Search

    2015-03-01

    This project applied commercial remote sensing and spatial information (CRS&SI) : technologies such as Ground Penetrating Radar (GPR), laser, GIS, and GPS to passenger rail : inspections. An integrated rail inspection system that can be mounted on hi...

  2. Video Guidance Sensor for Surface Mobility Operations

    NASA Technical Reports Server (NTRS)

    Fernandez, Kenneth R.; Fischer, Richard; Bryan, Thomas; Howell, Joe; Howard, Ricky; Peters, Bruce

    2008-01-01

    Robotic systems and surface mobility will play an increased role in future exploration missions. Unlike the LRV during Apollo era which was an astronaut piloted vehicle future systems will include teleoperated and semi-autonomous operations. The tasks given to these vehicles will run the range from infrastructure maintenance, ISRU, and construction to name a few. A common task that may be performed would be the retrieval and deployment of trailer mounted equipment. Operational scenarios may require these operations to be performed remotely via a teleoperated mode,or semi-autonomously. This presentation describes the on-going project to adapt the Automated Rendezvous and Capture (AR&C) sensor developed at the Marshall Space Flight Center for use in an automated trailer pick-up and deployment operation. The sensor which has been successfully demonstrated on-orbit has been mounted on an iRobot/John Deere RGATOR autonomous vehicle for this demonstration which will be completed in the March 2008 time-frame.

  3. Anchoring protein crystals to mounting loops with hydrogel using inkjet technology.

    PubMed

    Shinoda, Akira; Tanaka, Yoshikazu; Yao, Min; Tanaka, Isao

    2014-11-01

    X-ray crystallography is an important technique for structure-based drug discovery, mainly because it is the only technique that can reveal whether a ligand binds to the target protein as well as where and how it binds. However, ligand screening by X-ray crystallography involves a crystal-soaking experiment, which is usually performed manually. Thus, the throughput is not satisfactory for screening large numbers of candidate ligands. In this study, a technique to anchor protein crystals to mounting loops by using gel and inkjet technology has been developed; the method allows soaking of the mounted crystals in ligand-containing solution. This new technique may assist in the design of a fully automated drug-screening pipeline.

  4. Fast, Automated, Photo realistic, 3D Modeling of Building Interiors

    DTIC Science & Technology

    2016-09-12

    project, we developed two algorithmic pipelines for GPS-denied indoor mobile 3D mapping using an ambulatory backpack system. By mounting scanning...equipment on a backpack system, a human operator can traverse the interior of a building to produce a high-quality 3D reconstruction. In each of our...Unlimited UU UU UU UU 12-09-2016 1-May-2011 30-Jun-2015 Final Report: Fast, Automated, Photo-realistic, 3D Modeling of Building Interiors (ATTN

  5. Earth Observations taken by Expedition 41 crewmember

    NASA Image and Video Library

    2014-09-13

    ISS041-E-013683 (13 Sept. 2014) --- Photographed with a mounted automated camera, this is one of a number of images featuring the European Space Agency?s Automated Transfer Vehicle (ATV-5 or Georges Lemaitre) docked with the International Space Station. Except for color changes, the images are almost identical. The variation in color from frame to frame is due to the camera?s response to the motion of the orbital outpost, relative to the illumination from the sun.

  6. Earth Observations taken by Expedition 41 crewmember

    NASA Image and Video Library

    2014-09-13

    ISS041-E-013687 (13 Sept. 2014) --- Photographed with a mounted automated camera, this is one of a number of images featuring the European Space Agency?s Automated Transfer Vehicle (ATV-5 or Georges Lemaitre) docked with the International Space Station. Except for color changes, the images are almost identical. The variation in color from frame to frame is due to the camera?s response to the motion of the orbital outpost, relative to the illumination from the sun.

  7. Earth Observations taken by Expedition 41 crewmember

    NASA Image and Video Library

    2014-09-13

    ISS041-E-013693 (13 Sept. 2014) --- Photographed with a mounted automated camera, this is one of a number of images featuring the European Space Agency?s Automated Transfer Vehicle (ATV-5 or Georges Lemaitre) docked with the International Space Station. Except for color changes, the images are almost identical. The variation in color from frame to frame is due to the camera?s response to the motion of the orbital outpost, relative to the illumination from the sun.

  8. A fully automated digitally controlled 30-inch telescope

    NASA Technical Reports Server (NTRS)

    Colgate, S. A.; Moore, E. P.; Carlson, R.

    1975-01-01

    A fully automated 30-inch (75-cm) telescope has been successfully designed and constructed from a military surplus Nike-Ajax radar mount. Novel features include: closed-loop operation between mountain telescope and campus computer 30 km apart via microwave link, a TV-type sensor which is photon shot-noise limited, a special lightweight primary mirror, and a stepping motor drive capable of slewing and settling one degree in one second or a radian in fifteen seconds.

  9. Convenient mounting method for electrical measurements of thin samples

    NASA Technical Reports Server (NTRS)

    Matus, L. G.; Summers, R. L.

    1986-01-01

    A method for mounting thin samples for electrical measurements is described. The technique is based on a vacuum chuck concept in which the vacuum chuck simultaneously holds the sample and established electrical contact. The mounting plate is composed of a glass-ceramic insulating material and the surfaces of the plate and vacuum chuck are polished. The operation of the vacuum chuck is examined. The contacts on the sample and mounting plate, which are sputter-deposited through metal masks, are analyzed. The mounting method was utilized for van der Pauw measurements.

  10. Design of an automated cart and mount for a hyperspectral imaging system to be used in produce fields

    NASA Astrophysics Data System (ADS)

    Lefcourt, Alan M.; Kistler, Ross; Gadsden, S. Andrew

    2016-05-01

    The goal of this project was to construct a cart and a mounting system that would allow a hyperspectral laser-induced fluorescence imaging system (HLIFIS) to be used to detect fecal material in produce fields. Fecal contaminated produce is a recognized food safety risk. Previous research demonstrated the HLIFIS could detect fecal contamination in a laboratory setting. A cart was designed and built, and then tested to demonstrate that the cart was capable of moving at constant speeds or at precise intervals. A mounting system was designed and built to facilitate the critical alignment of the camera's imaging and the laser's illumination fields, and to allow the HLIFIS to be used in both field and laboratory settings without changing alignments. A hardened mount for the Powell lens that is used to produce the appropriate illumination profile was also designed, built, and tested.

  11. Engineering Design and Testing of a Novel High-Resolution Trace-Metal Clean Sampler for Profiling and Long-term Deployment Applications

    NASA Astrophysics Data System (ADS)

    Mueller, A. V.; Crusius, J.; Carlson, K.; Chapin, T. P.

    2016-02-01

    Design, assembly, and testing of a novel in-situ sampler for automated high-frequency trace-metal clean sampling at ocean moorings was undertaken with the goal of improving marine data density for iron (and other metals) by up to a factor of ten relative to existing samplers. Target characteristics are: modular, flexible use (profiling, static moorings, AUV-deployed), high capacity (100-200 samples), low power, low cost ($3k per 100-samples), ability to collect filtered + unfiltered samples, and simple assembly. Smaller sample volumes (10mL) are enabled by recent innovations in analysis techniques, while use of off-the-shelf components enables lower cost and faster development time, although attention must be taken to verify trace-metal cleanliness of materials in commercial products. Standard polypropylene syringes (tips with lock fittings) are adapted as sample chambers through fabrication of a dual (viton) o-ring replacement plunger to prevent barrel contamination between acid washing and sample collection. Syringes are mounted along a (pumped) sampling channel machined into a modular custom-designed 7.5in. HDPE ring; successive rings stack, fitted around the central 3 in. PVC pressure housing containing the pump, batteries, and temperature and pressure sensors. Optional filtering (0.45um) is easily added at the inlet to the pumped sampling line. Syringes, pre-filled with acid for sample preservation, are held "closed" using plastic zipties connected to the plunger pull; individual syringes are selected for filling by breaking a 0.003in. wire (e.g., stainless steel, gold-plated tungsten/rhenium) with a pulse of current or by melting the ziptie loop using a nichrome wire. Multiplexed addressing minimizes required microcontroller output pins and wires between the free-flooded collection chamber and the pressure housing. A novel, custom rotating inlet mounting scheme ensures that the pump tubing inlet remains positioned approximately 1m upstream of the sampler.

  12. Goniometer-based femtosecond crystallography with X-ray free electron lasers

    DOE PAGES

    Cohen, Aina E.; Soltis, S. Michael; González, Ana; ...

    2014-10-31

    The emerging method of femtosecond crystallography (FX) may extend the diffraction resolution accessible from small radiation-sensitive crystals and provides a means to determine catalytically accurate structures of acutely radiation-sensitive metalloenzymes. Automated goniometer-based instrumentation developed for use at the Linac Coherent Light Source enabled efficient and flexible FX experiments to be performed on a variety of sample types. In the case of rod-shaped Cpl hydrogenase crystals, only five crystals and about 30 min of beam time were used to obtain the 125 still diffraction patterns used to produce a 1.6-Å resolution electron density map. With smaller crystals, high-density grids were usedmore » to increase sample throughput; 930 myoglobin crystals mounted at random orientation inside 32 grids were exposed, demonstrating the utility of this approach. Screening results from cryocooled crystals of β 2-adrenoreceptor and an RNA polymerase II complex indicate the potential to extend the diffraction resolution obtainable from very radiation-sensitive samples beyond that possible with undulator-based synchrotron sources.« less

  13. Goniometer-based femtosecond crystallography with X-ray free electron lasers

    PubMed Central

    Cohen, Aina E.; Soltis, S. Michael; González, Ana; Aguila, Laura; Alonso-Mori, Roberto; Barnes, Christopher O.; Baxter, Elizabeth L.; Brehmer, Winnie; Brewster, Aaron S.; Brunger, Axel T.; Calero, Guillermo; Chang, Joseph F.; Chollet, Matthieu; Ehrensberger, Paul; Eriksson, Thomas L.; Feng, Yiping; Hattne, Johan; Hedman, Britt; Hollenbeck, Michael; Holton, James M.; Keable, Stephen; Kobilka, Brian K.; Kovaleva, Elena G.; Kruse, Andrew C.; Lemke, Henrik T.; Lin, Guowu; Lyubimov, Artem Y.; Manglik, Aashish; Mathews, Irimpan I.; McPhillips, Scott E.; Nelson, Silke; Peters, John W.; Sauter, Nicholas K.; Smith, Clyde A.; Song, Jinhu; Stevenson, Hilary P.; Tsai, Yingssu; Uervirojnangkoorn, Monarin; Vinetsky, Vladimir; Wakatsuki, Soichi; Weis, William I.; Zadvornyy, Oleg A.; Zeldin, Oliver B.; Zhu, Diling; Hodgson, Keith O.

    2014-01-01

    The emerging method of femtosecond crystallography (FX) may extend the diffraction resolution accessible from small radiation-sensitive crystals and provides a means to determine catalytically accurate structures of acutely radiation-sensitive metalloenzymes. Automated goniometer-based instrumentation developed for use at the Linac Coherent Light Source enabled efficient and flexible FX experiments to be performed on a variety of sample types. In the case of rod-shaped Cpl hydrogenase crystals, only five crystals and about 30 min of beam time were used to obtain the 125 still diffraction patterns used to produce a 1.6-Å resolution electron density map. For smaller crystals, high-density grids were used to increase sample throughput; 930 myoglobin crystals mounted at random orientation inside 32 grids were exposed, demonstrating the utility of this approach. Screening results from cryocooled crystals of β2-adrenoreceptor and an RNA polymerase II complex indicate the potential to extend the diffraction resolution obtainable from very radiation-sensitive samples beyond that possible with undulator-based synchrotron sources. PMID:25362050

  14. Miniaturization and automation of an internally cooled coated fiber device.

    PubMed

    Chen, Yong; Pawliszyn, Janusz

    2006-07-15

    The internally cooled coated fiber device was miniaturized to allow its direct introduction into a gas chromatography injector, while maintaining a reasonable lifetime of the septum. The device was robust, and its fiber, which was accommodated in an 18-gauge needle, was reproducibly used for more than 100 injections without any coating failure. The fiber temperature was controlled within 5 degrees C of the preset value by use of a temperature controller, a solenoid valve, and stainless steel tubings with different inner diameter. The device was mounted and used on the CTC CombiPAL autosampler with minor modifications, such as enlarging the hole of the needle guide of the autosampler and coupling the temperature control system of the device to the autosampler through a logic circuit. The device was validated with the back equilibration of hydrocarbons preloaded in the fiber in air. The automation of the internally cooled coated fiber device provided the feasibility of high throughput for the analysis of analytes in complex matrixes that required simultaneous heating of the sample matrixes and cooling of the fiber coating.

  15. Finding Interstellar Particle Impacts on Stardust Aluminium Foils: The Safe Handling, Imaging, and Analysis of Samples Containing Femtogram Residues

    NASA Technical Reports Server (NTRS)

    Kearsley, A. T.; Westphal, A. J.; Stadermann, F. J.; Armes, S. P.; Ball, A. D.; Borg, J.; Bridges, J. C.; Brownlee, D. E.; Burchell, M. J.; Chater, R. J.; hide

    2010-01-01

    Impact ionisation detectors on a suite of spacecraft have shown the direction, velocity, flux and mass distribution of smaller ISP entering the Solar System. During the aphelion segments of the Stardust flight, a dedicated collector surface was oriented to intercept ISP of beta = 1, and returned to Earth in January 2006. In this paper we describe the probable appeareance and size of IS particle craters from initial results of experimental impacts and numerical simulation, explain how foils are being prepared and mounted for crater searching by automated acquisition of high magnification electron images (whilst avoiding contamination of the foils) and comment on appropriate analytical techniques for Preliminary Examination (PE).

  16. Near-real-time information products for Mount St. Helens -- tracking the ongoing eruption: Chapter 3 in A volcano rekindled: the renewed eruption of Mount St. Helens, 2004-2006

    USGS Publications Warehouse

    Qamar, Anthony I.; Malone, Stephen; Moran, Seth C.; Steele, William P.; Thelen, Weston A.; Sherrod, David R.; Scott, William E.; Stauffer, Peter H.

    2008-01-01

    The rapid onset of energetic seismicity on September 23, 2004, at Mount St. Helens caused seismologists at the Pacific Northwest Seismic Network and the Cascades Volcano Observatory to quickly improve and develop techniques that summarized and displayed seismic parameters for use by scientists and the general public. Such techniques included webicorders (Web-based helicorder-like displays), graphs showing RSAM (real-time seismic amplitude measurements), RMS (root-mean-square) plots, spectrograms, location maps, automated seismic-event detectors, focal mechanism solutions, automated approximations of earthquake magnitudes, RSAM-based alarms, and time-depth plots for seismic events. Many of these visual-information products were made available publicly as Web pages generated and updated routinely. The graphs and maps included short written text that explained the concepts behind them, which increased their value to the nonseismologic community that was tracking the eruption. Laypeople could read online summaries of the scientific interpretations and, if they chose, review some of the basic data, thereby providing a better understanding of the data used by scientists to make interpretations about ongoing eruptive activity, as well as a better understanding of how scientists worked to monitor the volcano.

  17. Preparation of samples for leaf architecture studies, a method for mounting cleared leaves.

    PubMed

    Vasco, Alejandra; Thadeo, Marcela; Conover, Margaret; Daly, Douglas C

    2014-09-01

    Several recent waves of interest in leaf architecture have shown an expanding range of approaches and applications across a number of disciplines. Despite this increased interest, examination of existing archives of cleared and mounted leaves shows that current methods for mounting, in particular, yield unsatisfactory results and deterioration of samples over relatively short periods. Although techniques for clearing and staining leaves are numerous, published techniques for mounting leaves are scarce. • Here we present a complete protocol and recommendations for clearing, staining, and imaging leaves, and, most importantly, a method to permanently mount cleared leaves. • The mounting protocol is faster than other methods, inexpensive, and straightforward; moreover, it yields clear and permanent samples that can easily be imaged, scanned, and stored. Specimens mounted with this method preserve well, with leaves that were mounted more than 35 years ago showing no signs of bubbling or discoloration.

  18. Wireless canopy sensing network systems for automated control of irrigation and water use efficiency

    USDA-ARS?s Scientific Manuscript database

    Ground-based instrumentation for plant canopy sensing (infrared thermometry and spectral reflectance sensors) has been used extensively in agriculture to monitor crop status. Typically, measurements are accomplished with handheld or vehicle mounted instrumentation during limited periods of a day, an...

  19. Forensic Analysis of Human DNA from Samples Contamined with Bioweapons Agents

    DTIC Science & Technology

    2011-10-01

    Forensic analysis of human DNA from samples contaminated with bioweapons agents Jason Timbers Kathryn Wright Royal Canadian Mounted...Police Forensic Science and Identification Service Prepared By: Royal Canadian Mounted Police RCMP Forensic Science Identification Services... Royal Canadian Mounted Police Forensic Science and Identification Service Prepared By: Royal Canadian Mounted Police RCMP Forensic Science

  20. Tinning/Trimming Robot System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fureigh, M.L.

    In a new surface mount assembly area at AlliedSignal Inc., Kansas City Division (KCD), a tinning/trimming robot system tins and trims the gold-plated leads of surface mount technology (SMT) transistors. The KCD-designed system uses a Unimation PUMA 260 robot, a General Production Devices SP-2000 solder pot; water-soluble Blackstone No. 2508 flux; and a Virtual Industries high-temperature, ESD-conductive, miniature suction cup. After the manual cleaning operation, the processed SMT transistors go to the QUADSTAR Automated Component Placement System for a Radar Logic Assembly. The benefits are reductions in the cost of nonconformance, worker fatigue, and standard hours.

  1. A Robotic Platform for Corn Seedling Morphological Traits Characterization

    PubMed Central

    Lu, Hang; Tang, Lie; Whitham, Steven A.; Mei, Yu

    2017-01-01

    Crop breeding plays an important role in modern agriculture, improving plant performance, and increasing yield. Identifying the genes that are responsible for beneficial traits greatly facilitates plant breeding efforts for increasing crop production. However, associating genes and their functions with agronomic traits requires researchers to observe, measure, record, and analyze phenotypes of large numbers of plants, a repetitive and error-prone job if performed manually. An automated seedling phenotyping system aimed at replacing manual measurement, reducing sampling time, and increasing the allowable work time is thus highly valuable. Toward this goal, we developed an automated corn seedling phenotyping platform based on a time-of-flight of light (ToF) camera and an industrial robot arm. A ToF camera is mounted on the end effector of the robot arm. The arm positions the ToF camera at different viewpoints for acquiring 3D point cloud data. A camera-to-arm transformation matrix was calculated using a hand-eye calibration procedure and applied to transfer different viewpoints into an arm-based coordinate frame. Point cloud data filters were developed to remove the noise in the background and in the merged seedling point clouds. A 3D-to-2D projection and an x-axis pixel density distribution method were used to segment the stem and leaves. Finally, separated leaves were fitted with 3D curves for morphological traits characterization. This platform was tested on a sample of 60 corn plants at their early growth stages with between two to five leaves. The error ratios of the stem height and leave length measurements are 13.7% and 13.1%, respectively, demonstrating the feasibility of this robotic system for automated corn seedling phenotyping. PMID:28895892

  2. A Robotic Platform for Corn Seedling Morphological Traits Characterization.

    PubMed

    Lu, Hang; Tang, Lie; Whitham, Steven A; Mei, Yu

    2017-09-12

    Crop breeding plays an important role in modern agriculture, improving plant performance, and increasing yield. Identifying the genes that are responsible for beneficial traits greatly facilitates plant breeding efforts for increasing crop production. However, associating genes and their functions with agronomic traits requires researchers to observe, measure, record, and analyze phenotypes of large numbers of plants, a repetitive and error-prone job if performed manually. An automated seedling phenotyping system aimed at replacing manual measurement, reducing sampling time, and increasing the allowable work time is thus highly valuable. Toward this goal, we developed an automated corn seedling phenotyping platform based on a time-of-flight of light (ToF) camera and an industrial robot arm. A ToF camera is mounted on the end effector of the robot arm. The arm positions the ToF camera at different viewpoints for acquiring 3D point cloud data. A camera-to-arm transformation matrix was calculated using a hand-eye calibration procedure and applied to transfer different viewpoints into an arm-based coordinate frame. Point cloud data filters were developed to remove the noise in the background and in the merged seedling point clouds. A 3D-to-2D projection and an x -axis pixel density distribution method were used to segment the stem and leaves. Finally, separated leaves were fitted with 3D curves for morphological traits characterization. This platform was tested on a sample of 60 corn plants at their early growth stages with between two to five leaves. The error ratios of the stem height and leave length measurements are 13.7% and 13.1%, respectively, demonstrating the feasibility of this robotic system for automated corn seedling phenotyping.

  3. Preparation of samples for leaf architecture studies, a method for mounting cleared leaves1

    PubMed Central

    Vasco, Alejandra; Thadeo, Marcela; Conover, Margaret; Daly, Douglas C.

    2014-01-01

    • Premise of the study: Several recent waves of interest in leaf architecture have shown an expanding range of approaches and applications across a number of disciplines. Despite this increased interest, examination of existing archives of cleared and mounted leaves shows that current methods for mounting, in particular, yield unsatisfactory results and deterioration of samples over relatively short periods. Although techniques for clearing and staining leaves are numerous, published techniques for mounting leaves are scarce. • Methods and Results: Here we present a complete protocol and recommendations for clearing, staining, and imaging leaves, and, most importantly, a method to permanently mount cleared leaves. • Conclusions: The mounting protocol is faster than other methods, inexpensive, and straightforward; moreover, it yields clear and permanent samples that can easily be imaged, scanned, and stored. Specimens mounted with this method preserve well, with leaves that were mounted more than 35 years ago showing no signs of bubbling or discoloration. PMID:25225627

  4. Integrated crystal mounting and alignment system for high-throughput biological crystallography

    DOEpatents

    Nordmeyer, Robert A.; Snell, Gyorgy P.; Cornell, Earl W.; Kolbe, William F.; Yegian, Derek T.; Earnest, Thomas N.; Jaklevich, Joseph M.; Cork, Carl W.; Santarsiero, Bernard D.; Stevens, Raymond C.

    2007-09-25

    A method and apparatus for the transportation, remote and unattended mounting, and visual alignment and monitoring of protein crystals for synchrotron generated x-ray diffraction analysis. The protein samples are maintained at liquid nitrogen temperatures at all times: during shipment, before mounting, mounting, alignment, data acquisition and following removal. The samples must additionally be stably aligned to within a few microns at a point in space. The ability to accurately perform these tasks remotely and automatically leads to a significant increase in sample throughput and reliability for high-volume protein characterization efforts. Since the protein samples are placed in a shipping-compatible layered stack of sample cassettes each holding many samples, a large number of samples can be shipped in a single cryogenic shipping container.

  5. Integrated crystal mounting and alignment system for high-throughput biological crystallography

    DOEpatents

    Nordmeyer, Robert A.; Snell, Gyorgy P.; Cornell, Earl W.; Kolbe, William; Yegian, Derek; Earnest, Thomas N.; Jaklevic, Joseph M.; Cork, Carl W.; Santarsiero, Bernard D.; Stevens, Raymond C.

    2005-07-19

    A method and apparatus for the transportation, remote and unattended mounting, and visual alignment and monitoring of protein crystals for synchrotron generated x-ray diffraction analysis. The protein samples are maintained at liquid nitrogen temperatures at all times: during shipment, before mounting, mounting, alignment, data acquisition and following removal. The samples must additionally be stably aligned to within a few microns at a point in space. The ability to accurately perform these tasks remotely and automatically leads to a significant increase in sample throughput and reliability for high-volume protein characterization efforts. Since the protein samples are placed in a shipping-compatible layered stack of sample cassettes each holding many samples, a large number of samples can be shipped in a single cryogenic shipping container.

  6. Comparative analysis of whole mount processing and systematic sampling of radical prostatectomy specimens: pathological outcomes and risk of biochemical recurrence.

    PubMed

    Salem, Shady; Chang, Sam S; Clark, Peter E; Davis, Rodney; Herrell, S Duke; Kordan, Yakup; Wills, Marcia L; Shappell, Scott B; Baumgartner, Roxelyn; Phillips, Sharon; Smith, Joseph A; Cookson, Michael S; Barocas, Daniel A

    2010-10-01

    Whole mount processing is more resource intensive than routine systematic sampling of radical retropubic prostatectomy specimens. We compared whole mount and systematic sampling for detecting pathological outcomes, and compared the prognostic value of pathological findings across pathological methods. We included men (608 whole mount and 525 systematic sampling samples) with no prior treatment who underwent radical retropubic prostatectomy at Vanderbilt University Medical Center between January 2000 and June 2008. We used univariate and multivariate analysis to compare the pathological outcome detection rate between pathological methods. Kaplan-Meier curves and the log rank test were used to compare the prognostic value of pathological findings across pathological methods. There were no significant differences between the whole mount and the systematic sampling groups in detecting extraprostatic extension (25% vs 30%), positive surgical margins (31% vs 31%), pathological Gleason score less than 7 (49% vs 43%), 7 (39% vs 43%) or greater than 7 (12% vs 13%), seminal vesicle invasion (8% vs 10%) or lymph node involvement (3% vs 5%). Tumor volume was higher in the systematic sampling group and whole mount detected more multiple surgical margins (each p <0.01). There were no significant differences in the likelihood of biochemical recurrence between the pathological methods when patients were stratified by pathological outcome. Except for estimated tumor volume and multiple margins whole mount and systematic sampling yield similar pathological information. Each method stratifies patients into comparable risk groups for biochemical recurrence. Thus, while whole mount is more resource intensive, it does not appear to result in improved detection of clinically important pathological outcomes or prognostication. Copyright © 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. Towards a compact and precise sample holder for macromolecular crystallography.

    PubMed

    Papp, Gergely; Rossi, Christopher; Janocha, Robert; Sorez, Clement; Lopez-Marrero, Marcos; Astruc, Anthony; McCarthy, Andrew; Belrhali, Hassan; Bowler, Matthew W; Cipriani, Florent

    2017-10-01

    Most of the sample holders currently used in macromolecular crystallography offer limited storage density and poor initial crystal-positioning precision upon mounting on a goniometer. This has now become a limiting factor at high-throughput beamlines, where data collection can be performed in a matter of seconds. Furthermore, this lack of precision limits the potential benefits emerging from automated harvesting systems that could provide crystal-position information which would further enhance alignment at beamlines. This situation provided the motivation for the development of a compact and precise sample holder with corresponding pucks, handling tools and robotic transfer protocols. The development process included four main phases: design, prototype manufacture, testing with a robotic sample changer and validation under real conditions on a beamline. Two sample-holder designs are proposed: NewPin and miniSPINE. They share the same robot gripper and allow the storage of 36 sample holders in uni-puck footprint-style pucks, which represents 252 samples in a dry-shipping dewar commonly used in the field. The pucks are identified with human- and machine-readable codes, as well as with radio-frequency identification (RFID) tags. NewPin offers a crystal-repositioning precision of up to 10 µm but requires a specific goniometer socket. The storage density could reach 64 samples using a special puck designed for fully robotic handling. miniSPINE is less precise but uses a goniometer mount compatible with the current SPINE standard. miniSPINE is proposed for the first implementation of the new standard, since it is easier to integrate at beamlines. An upgraded version of the SPINE sample holder with a corresponding puck named SPINEplus is also proposed in order to offer a homogenous and interoperable system. The project involved several European synchrotrons and industrial companies in the fields of consumables and sample-changer robotics. Manual handling of miniSPINE was tested at different institutes using evaluation kits, and pilot beamlines are being equipped with compatible robotics for large-scale evaluation. A companion paper describes a new sample changer FlexED8 (Papp et al., 2017, Acta Cryst., D73, 841-851).

  8. An automated inner dimensional measurement system based on a laser displacement sensor for long-stepped pipes.

    PubMed

    Zhang, Fumin; Qu, Xinghua; Ouyang, Jianfei

    2012-01-01

    A novel measurement prototype based on a mobile vehicle that carries a laser scanning sensor is proposed. The prototype is intended for the automated measurement of the interior 3D geometry of large-diameter long-stepped pipes. The laser displacement sensor, which has a small measurement range, is mounted on an extended arm of known length. It is scanned to improve the measurement accuracy for large-sized pipes. A fixing mechanism based on two sections is designed to ensure that the stepped pipe is concentric with the axis of rotation of the system. Data are acquired in a cylindrical coordinate system and fitted in a circle to determine diameter. Systematic errors covering arm length, tilt, and offset errors are analyzed and calibrated. The proposed system is applied to sample parts and the results are discussed to verify its effectiveness. This technique measures a diameter of 600 mm with an uncertainty of 0.02 mm at a 95% confidence probability. A repeatability test is performed to examine precision, which is 1.1 μm. A laser tracker is used to verify the measurement accuracy of the system, which is evaluated as 9 μm within a diameter of 600 mm.

  9. Objective and automated measurement of dynamic vision functions

    NASA Technical Reports Server (NTRS)

    Flom, M. C.; Adams, A. J.

    1976-01-01

    A phoria stimulus array and electro-oculographic (EOG) arrangements for measuring motor and sensory responses of subjects subjected to stress or drug conditions are described, along with experimental procedures. Heterophoria (as oculomotor function) and glare recovery time (time required for photochemical and neural recovery after exposure to a flash stimulus) are measured, in research aimed at developing automated objective measurement of dynamic vision functions. Onset of involuntary optokinetic nystagmus in subjects attempting to track moving stripes (while viewing through head-mounted binocular eyepieces) after exposure to glare serves as an objective measure of glare recovery time.

  10. Pilot vehicle interface on the advanced fighter technology integration F-16

    NASA Technical Reports Server (NTRS)

    Dana, W. H.; Smith, W. B.; Howard, J. D.

    1986-01-01

    This paper focuses on the work load aspects of the pilot vehicle interface in regard to the new technologies tested during AMAS Phase II. Subjects discussed in this paper include: a wide field-of-view head-up display; automated maneuvering attack system/sensor tracker system; master modes that configure flight controls and mission avionics; a modified helmet mounted sight; improved multifunction display capability; a voice interactive command system; ride qualities during automated weapon delivery; a color moving map; an advanced digital map display; and a g-induced loss-of-consciousness and spatial disorientation autorecovery system.

  11. Control and materials characterization System for 6T Superconducting Cryogen Free Magnet Facility at IUAC, New Delhi

    NASA Astrophysics Data System (ADS)

    Dutt, R. N.; Meena, D. K.; Kar, S.; Soni, V.; Nadaf, A.; Das, A.; Singh, F.; Datta, T. S.

    2017-02-01

    A system for carrying out automatic experimental measurements of various electrical transport characteristics and their relation to magnetic fields for samples mounted on the sample holder on a Variable Temperature Insert (VTI) of the Cryogen Free Superconducting Magnet System (CFMS) has been developed. The control and characterization system is capable of monitoring, online plotting and history logging in real-time of cryogenic temperatures with the Silicon (Si) Diode and Zirconium Oxy-Nitride sensors installed inside the magnet facility. Electrical transport property measurements have been automated with implementation of current reversal resistance measurements and automatic temperature set-point ramping with the parameters of interest available in real-time as well as for later analysis. The Graphical User Interface (GUI) based system is user friendly to facilitate operations. An ingenious electronics for reading Zirconium Oxy-Nitride temperature sensors has been used. Price to performance ratio has been optimized by using in house developed measurement techniques mixed with specialized commercial cryogenic measurement / control equipment.

  12. Quick-change filter cartridge

    DOEpatents

    Rodgers, John C.; McFarland, Andrew R.; Ortiz, Carlos A.

    1995-01-01

    A quick-change filter cartridge. In sampling systems for measurement of airborne materials, a filter element is introduced into the sampled airstream such that the aerosol constituents are removed and deposited on the filter. Fragile sampling media often require support in order to prevent rupture during sampling, and careful mounting and sealing to prevent misalignment, tearing, or creasing which would allow the sampled air to bypass the filter. Additionally, handling of filter elements may introduce cross-contamination or exposure of operators to toxic materials. Moreover, it is desirable to enable the preloading of filter media into quick-change cartridges in clean laboratory environments, thereby simplifying and expediting the filter-changing process in the field. The quick-change filter cartridge of the present invention permits the application of a variety of filter media in many types of instruments and may also be used in automated systems. The cartridge includes a base through which a vacuum can be applied to draw air through the filter medium which is located on a porous filter support and held there by means of a cap which forms an airtight seal with the base. The base is also adapted for receiving absorbing media so that both particulates and gas-phase samples may be trapped for investigation, the latter downstream of the aerosol filter.

  13. Automated detection of submerged navigational obstructions in freshwater impoundments with hull mounted sidescan sonar

    NASA Astrophysics Data System (ADS)

    Morris, Phillip A.

    The prevalence of low-cost side scanning sonar systems mounted on small recreational vessels has created improved opportunities to identify and map submerged navigational hazards in freshwater impoundments. However, these economical sensors also present unique challenges for automated techniques. This research explores related literature in automated sonar imagery processing and mapping technology, proposes and implements a framework derived from these sources, and evaluates the approach with video collected from a recreational grade sonar system. Image analysis techniques including optical character recognition and an unsupervised computer automated detection (CAD) algorithm are employed to extract the transducer GPS coordinates and slant range distance of objects protruding from the lake bottom. The retrieved information is formatted for inclusion into a spatial mapping model. Specific attributes of the sonar sensors are modeled such that probability profiles may be projected onto a three dimensional gridded map. These profiles are computed from multiple points of view as sonar traces crisscross or come near each other. As lake levels fluctuate over time so do the elevation points of view. With each sonar record, the probability of a hazard existing at certain elevations at the respective grid points is updated with Bayesian mechanics. As reinforcing data is collected, the confidence of the map improves. Given a lake's current elevation and a vessel draft, a final generated map can identify areas of the lake that have a high probability of containing hazards that threaten navigation. The approach is implemented in C/C++ utilizing OpenCV, Tesseract OCR, and QGIS open source software and evaluated in a designated test area at Lake Lavon, Collin County, Texas.

  14. A microfluidic device for preparing next generation DNA sequencing libraries and for automating other laboratory protocols that require one or more column chromatography steps.

    PubMed

    Tan, Swee Jin; Phan, Huan; Gerry, Benjamin Michael; Kuhn, Alexandre; Hong, Lewis Zuocheng; Min Ong, Yao; Poon, Polly Suk Yean; Unger, Marc Alexander; Jones, Robert C; Quake, Stephen R; Burkholder, William F

    2013-01-01

    Library preparation for next-generation DNA sequencing (NGS) remains a key bottleneck in the sequencing process which can be relieved through improved automation and miniaturization. We describe a microfluidic device for automating laboratory protocols that require one or more column chromatography steps and demonstrate its utility for preparing Next Generation sequencing libraries for the Illumina and Ion Torrent platforms. Sixteen different libraries can be generated simultaneously with significantly reduced reagent cost and hands-on time compared to manual library preparation. Using an appropriate column matrix and buffers, size selection can be performed on-chip following end-repair, dA tailing, and linker ligation, so that the libraries eluted from the chip are ready for sequencing. The core architecture of the device ensures uniform, reproducible column packing without user supervision and accommodates multiple routine protocol steps in any sequence, such as reagent mixing and incubation; column packing, loading, washing, elution, and regeneration; capture of eluted material for use as a substrate in a later step of the protocol; and removal of one column matrix so that two or more column matrices with different functional properties can be used in the same protocol. The microfluidic device is mounted on a plastic carrier so that reagents and products can be aliquoted and recovered using standard pipettors and liquid handling robots. The carrier-mounted device is operated using a benchtop controller that seals and operates the device with programmable temperature control, eliminating any requirement for the user to manually attach tubing or connectors. In addition to NGS library preparation, the device and controller are suitable for automating other time-consuming and error-prone laboratory protocols requiring column chromatography steps, such as chromatin immunoprecipitation.

  15. A Microfluidic Device for Preparing Next Generation DNA Sequencing Libraries and for Automating Other Laboratory Protocols That Require One or More Column Chromatography Steps

    PubMed Central

    Tan, Swee Jin; Phan, Huan; Gerry, Benjamin Michael; Kuhn, Alexandre; Hong, Lewis Zuocheng; Min Ong, Yao; Poon, Polly Suk Yean; Unger, Marc Alexander; Jones, Robert C.; Quake, Stephen R.; Burkholder, William F.

    2013-01-01

    Library preparation for next-generation DNA sequencing (NGS) remains a key bottleneck in the sequencing process which can be relieved through improved automation and miniaturization. We describe a microfluidic device for automating laboratory protocols that require one or more column chromatography steps and demonstrate its utility for preparing Next Generation sequencing libraries for the Illumina and Ion Torrent platforms. Sixteen different libraries can be generated simultaneously with significantly reduced reagent cost and hands-on time compared to manual library preparation. Using an appropriate column matrix and buffers, size selection can be performed on-chip following end-repair, dA tailing, and linker ligation, so that the libraries eluted from the chip are ready for sequencing. The core architecture of the device ensures uniform, reproducible column packing without user supervision and accommodates multiple routine protocol steps in any sequence, such as reagent mixing and incubation; column packing, loading, washing, elution, and regeneration; capture of eluted material for use as a substrate in a later step of the protocol; and removal of one column matrix so that two or more column matrices with different functional properties can be used in the same protocol. The microfluidic device is mounted on a plastic carrier so that reagents and products can be aliquoted and recovered using standard pipettors and liquid handling robots. The carrier-mounted device is operated using a benchtop controller that seals and operates the device with programmable temperature control, eliminating any requirement for the user to manually attach tubing or connectors. In addition to NGS library preparation, the device and controller are suitable for automating other time-consuming and error-prone laboratory protocols requiring column chromatography steps, such as chromatin immunoprecipitation. PMID:23894273

  16. Self-optimizing approach for automated laser resonator alignment

    NASA Astrophysics Data System (ADS)

    Brecher, C.; Schmitt, R.; Loosen, P.; Guerrero, V.; Pyschny, N.; Pavim, A.; Gatej, A.

    2012-02-01

    Nowadays, the assembly of laser systems is dominated by manual operations, involving elaborate alignment by means of adjustable mountings. From a competition perspective, the most challenging problem in laser source manufacturing is price pressure, a result of cost competition exerted mainly from Asia. From an economical point of view, an automated assembly of laser systems defines a better approach to produce more reliable units at lower cost. However, the step from today's manual solutions towards an automated assembly requires parallel developments regarding product design, automation equipment and assembly processes. This paper introduces briefly the idea of self-optimizing technical systems as a new approach towards highly flexible automation. Technically, the work focuses on the precision assembly of laser resonators, which is one of the final and most crucial assembly steps in terms of beam quality and laser power. The paper presents a new design approach for miniaturized laser systems and new automation concepts for a robot-based precision assembly, as well as passive and active alignment methods, which are based on a self-optimizing approach. Very promising results have already been achieved, considerably reducing the duration and complexity of the laser resonator assembly. These results as well as future development perspectives are discussed.

  17. An 8-Fold Parallel Reactor System for Combinatorial Catalysis Research

    PubMed Central

    Stoll, Norbert; Allwardt, Arne; Dingerdissen, Uwe

    2006-01-01

    Increasing economic globalization and mounting time and cost pressure on the development of new raw materials for the chemical industry as well as materials and environmental engineering constantly raise the demands on technologies to be used. Parallelization, miniaturization, and automation are the main concepts involved in increasing the rate of chemical and biological experimentation. PMID:17671621

  18. Design and flight evaluation of an integrated navigation and near-terrain helicopter guidance system for night-time and adverse weather operations

    NASA Technical Reports Server (NTRS)

    Swenson, Harry N.; Zelenka, Richard E.; Dearing, Munro G.; Hardy, Gordon H.; Clark, Raymond; Davis, Tom; Amatrudo, Gary; Zirkler, Andre

    1994-01-01

    NASA and the U.S. Army have designed, developed, and flight evaluated a Computer Aiding for Low Altitude Helicopter Flight (CALAHF) guidance system. This system provides guidance to the pilot for near terrain covert helicopter operations. It automates the processing of precision navigation information, helicopter mission requirements, and terrain flight guidance. The automation is presented to the pilot through symbology on a helmet-mounted display. The symbology is a 'pilot-centered' design which preserves pilot flexibility and authority over the CALAHF system's automation. An extensive flight evaluation of the system has been conducted using the U.S. Army's NUH-60 STAR (Systems Testbed for Avionics Research) research helicopter. The evaluations were flown over a multiwaypoint helicopter mission in rugged mountainous terrain, at terrain clearance altitudes from 300 to 125 ft and airspeeds from 40 to 110 knots. The results of these evaluations showed that the pilots could precisely follow the automation symbology while maintaining a high degree of situational awareness.

  19. Space biology initiative program definition review. Trade study 1: Automation costs versus crew utilization

    NASA Technical Reports Server (NTRS)

    Jackson, L. Neal; Crenshaw, John, Sr.; Hambright, R. N.; Nedungadi, A.; Mcfayden, G. M.; Tsuchida, M. S.

    1989-01-01

    A significant emphasis upon automation within the Space Biology Initiative hardware appears justified in order to conserve crew labor and crew training effort. Two generic forms of automation were identified: automation of data and information handling and decision making, and the automation of material handling, transfer, and processing. The use of automatic data acquisition, expert systems, robots, and machine vision will increase the volume of experiments and quality of results. The automation described may also influence efforts to miniaturize and modularize the large array of SBI hardware identified to date. The cost and benefit model developed appears to be a useful guideline for SBI equipment specifiers and designers. Additional refinements would enhance the validity of the model. Two NASA automation pilot programs, 'The Principal Investigator in a Box' and 'Rack Mounted Robots' were investigated and found to be quite appropriate for adaptation to the SBI program. There are other in-house NASA efforts that provide technology that may be appropriate for the SBI program. Important data is believed to exist in advanced medical labs throughout the U.S., Japan, and Europe. The information and data processing in medical analysis equipment is highly automated and future trends reveal continued progress in this area. However, automation of material handling and processing has progressed in a limited manner because the medical labs are not affected by the power and space constraints that Space Station medical equipment is faced with. Therefore, NASA's major emphasis in automation will require a lead effort in the automation of material handling to achieve optimal crew utilization.

  20. Hemispherical Laue camera

    DOEpatents

    Li, James C. M.; Chu, Sungnee G.

    1980-01-01

    A hemispherical Laue camera comprises a crystal sample mount for positioning a sample to be analyzed at the center of sphere of a hemispherical, X-radiation sensitive film cassette, a collimator, a stationary or rotating sample mount and a set of standard spherical projection spheres. X-radiation generated from an external source is directed through the collimator to impinge onto the single crystal sample on the stationary mount. The diffracted beam is recorded on the hemispherical X-radiation sensitive film mounted inside the hemispherical film cassette in either transmission or back-reflection geometry. The distances travelled by X-radiation diffracted from the crystal to the hemispherical film are the same for all crystal planes which satisfy Bragg's Law. The recorded diffraction spots or Laue spots on the film thereby preserve both the symmetry information of the crystal structure and the relative intensities which are directly related to the relative structure factors of the crystal orientations. The diffraction pattern on the exposed film is compared with the known diffraction pattern on one of the standard spherical projection spheres for a specific crystal structure to determine the orientation of the crystal sample. By replacing the stationary sample support with a rotating sample mount, the hemispherical Laue camera can be used for crystal structure determination in a manner previously provided in conventional Debye-Scherrer cameras.

  1. Catalog of Mount St. Helens 2004-2007 Dome Samples with Major- and Trace-Element Chemistry

    USGS Publications Warehouse

    Thornber, Carl R.; Pallister, John S.; Rowe, Michael C.; McConnell, Siobhan; Herriott, Trystan M.; Eckberg, Alison; Stokes, Winston C.; Cornelius, Diane Johnson; Conrey, Richard M.; Hannah, Tammy; Taggart, Joseph E.; Adams, Monique; Lamothe, Paul J.; Budahn, James R.; Knaack, Charles M.

    2008-01-01

    Sampling and analysis of eruptive products at Mount St. Helens is an integral part of volcano monitoring efforts conducted by the U.S. Geological Survey?s Cascades Volcano Observatory (CVO). The objective of our eruption sampling program is to enable petrological assessments of pre-eruptive magmatic conditions, critical for ascertaining mechanisms for eruption triggering and forecasting potential changes in eruption behavior. This report provides a catalog of near-vent lithic debris and new dome-lava collected during 34 intra-crater sampling forays throughout the October 2004 to October 2007 (2004?7) eruptive interval at Mount St. Helens. In addition, we present comprehensive bulk-rock geochemistry for a time-series of representative (2004?7) eruption products. This data, along with that in a companion report on Mount St. Helens 2004 to 2006 tephra by Rowe and others (2008), are presented in support of the contents of the U.S. Geological Survey Professional Paper 1750 (Sherrod and others, eds., 2008). Readers are referred to appropriate chapters in USGS Professional Paper 1750 for detailed narratives of eruptive activity during this time period and for interpretations of sample characteristics and geochemical data. The suite of rock samples related to the 2004?7 eruption of Mount St. Helens and presented in this catalog are archived at the David A. Johnson Cascades Volcano Observatory, Vancouver, Wash. The Mount St. Helens 2004?7 Dome Sample Catalogue with major- and trace-element geochemistry is tabulated in 3 worksheets of the accompanying Microsoft Excel file, of2008-1130.xls. Table 1 provides location and sampling information. Table 2 presents sample descriptions. In table 3, bulk-rock major and trace-element geochemistry is listed for 44 eruption-related samples with intra-laboratory replicate analyses of 19 dacite lava samples. A brief overview of the collection methods and lithology of dome samples is given below as an aid to deciphering the dome sample catalog. This is followed by an explanation of the categories of sample information (column headers) in Tables 1 and 2. A summary of the analytical methods used to obtain the geochemical data in this report introduces the presentation of major- and trace-element geochemistry of 2004?7 Mount St. Helens dome samples in table 3. Intra-laboratory results for the USGS AGV-2 standard are presented (tables 4 and 5), which demonstrate the compatibility of chemical data from different sources.

  2. Automated Protist Analysis of Complex Samples: Recent Investigations Using Motion and Thresholding

    DTIC Science & Technology

    2012-01-01

    Report No: CG-D-15-13 Automated Protist Analysis of Complex Samples: Recent Investigations Using Motion and Thresholding...Distribution Statement A: Approved for public release; distribution is unlimited. January 2012 Automated Protist Analysis of Complex Samples...Chelsea Street New London, CT 06320 Automated Protist Analysis of Complex Samples iii UNCLAS//PUBLIC | CG-926 R&DC | B. Nelson, et al

  3. An Automated Inner Dimensional Measurement System Based on a Laser Displacement Sensor for Long-Stepped Pipes

    PubMed Central

    Zhang, Fumin; Qu, Xinghua; Ouyang, Jianfei

    2012-01-01

    A novel measurement prototype based on a mobile vehicle that carries a laser scanning sensor is proposed. The prototype is intended for the automated measurement of the interior 3D geometry of large-diameter long-stepped pipes. The laser displacement sensor, which has a small measurement range, is mounted on an extended arm of known length. It is scanned to improve the measurement accuracy for large-sized pipes. A fixing mechanism based on two sections is designed to ensure that the stepped pipe is concentric with the axis of rotation of the system. Data are acquired in a cylindrical coordinate system and fitted in a circle to determine diameter. Systematic errors covering arm length, tilt, and offset errors are analyzed and calibrated. The proposed system is applied to sample parts and the results are discussed to verify its effectiveness. This technique measures a diameter of 600 mm with an uncertainty of 0.02 mm at a 95% confidence probability. A repeatability test is performed to examine precision, which is 1.1 μm. A laser tracker is used to verify the measurement accuracy of the system, which is evaluated as 9 μm within a diameter of 600 mm. PMID:22778615

  4. Classification of Mobile Laser Scanning Point Clouds from Height Features

    NASA Astrophysics Data System (ADS)

    Zheng, M.; Lemmens, M.; van Oosterom, P.

    2017-09-01

    The demand for 3D maps of cities and road networks is steadily growing and mobile laser scanning (MLS) systems are often the preferred geo-data acquisition method for capturing such scenes. Because MLS systems are mounted on cars or vans they can acquire billions of points of road scenes within a few hours of survey. Manual processing of point clouds is labour intensive and thus time consuming and expensive. Hence, the need for rapid and automated methods for 3D mapping of dense point clouds is growing exponentially. The last five years the research on automated 3D mapping of MLS data has tremendously intensified. In this paper, we present our work on automated classification of MLS point clouds. In the present stage of the research we exploited three features - two height components and one reflectance value, and achieved an overall accuracy of 73 %, which is really encouraging for further refining our approach.

  5. Mapping a multiplexed zoo of mRNA expression.

    PubMed

    Choi, Harry M T; Calvert, Colby R; Husain, Naeem; Huss, David; Barsi, Julius C; Deverman, Benjamin E; Hunter, Ryan C; Kato, Mihoko; Lee, S Melanie; Abelin, Anna C T; Rosenthal, Adam Z; Akbari, Omar S; Li, Yuwei; Hay, Bruce A; Sternberg, Paul W; Patterson, Paul H; Davidson, Eric H; Mazmanian, Sarkis K; Prober, David A; van de Rijn, Matt; Leadbetter, Jared R; Newman, Dianne K; Readhead, Carol; Bronner, Marianne E; Wold, Barbara; Lansford, Rusty; Sauka-Spengler, Tatjana; Fraser, Scott E; Pierce, Niles A

    2016-10-01

    In situ hybridization methods are used across the biological sciences to map mRNA expression within intact specimens. Multiplexed experiments, in which multiple target mRNAs are mapped in a single sample, are essential for studying regulatory interactions, but remain cumbersome in most model organisms. Programmable in situ amplifiers based on the mechanism of hybridization chain reaction (HCR) overcome this longstanding challenge by operating independently within a sample, enabling multiplexed experiments to be performed with an experimental timeline independent of the number of target mRNAs. To assist biologists working across a broad spectrum of organisms, we demonstrate multiplexed in situ HCR in diverse imaging settings: bacteria, whole-mount nematode larvae, whole-mount fruit fly embryos, whole-mount sea urchin embryos, whole-mount zebrafish larvae, whole-mount chicken embryos, whole-mount mouse embryos and formalin-fixed paraffin-embedded human tissue sections. In addition to straightforward multiplexing, in situ HCR enables deep sample penetration, high contrast and subcellular resolution, providing an incisive tool for the study of interlaced and overlapping expression patterns, with implications for research communities across the biological sciences. © 2016. Published by The Company of Biologists Ltd.

  6. Mapping a multiplexed zoo of mRNA expression

    PubMed Central

    Choi, Harry M. T.; Calvert, Colby R.; Husain, Naeem; Huss, David; Barsi, Julius C.; Deverman, Benjamin E.; Hunter, Ryan C.; Kato, Mihoko; Lee, S. Melanie; Abelin, Anna C. T.; Rosenthal, Adam Z.; Akbari, Omar S.; Li, Yuwei; Hay, Bruce A.; Sternberg, Paul W.; Patterson, Paul H.; Davidson, Eric H.; Mazmanian, Sarkis K.; Prober, David A.; van de Rijn, Matt; Leadbetter, Jared R.; Newman, Dianne K.; Readhead, Carol; Bronner, Marianne E.; Wold, Barbara; Lansford, Rusty; Sauka-Spengler, Tatjana; Fraser, Scott E.

    2016-01-01

    In situ hybridization methods are used across the biological sciences to map mRNA expression within intact specimens. Multiplexed experiments, in which multiple target mRNAs are mapped in a single sample, are essential for studying regulatory interactions, but remain cumbersome in most model organisms. Programmable in situ amplifiers based on the mechanism of hybridization chain reaction (HCR) overcome this longstanding challenge by operating independently within a sample, enabling multiplexed experiments to be performed with an experimental timeline independent of the number of target mRNAs. To assist biologists working across a broad spectrum of organisms, we demonstrate multiplexed in situ HCR in diverse imaging settings: bacteria, whole-mount nematode larvae, whole-mount fruit fly embryos, whole-mount sea urchin embryos, whole-mount zebrafish larvae, whole-mount chicken embryos, whole-mount mouse embryos and formalin-fixed paraffin-embedded human tissue sections. In addition to straightforward multiplexing, in situ HCR enables deep sample penetration, high contrast and subcellular resolution, providing an incisive tool for the study of interlaced and overlapping expression patterns, with implications for research communities across the biological sciences. PMID:27702788

  7. Automated Slide Scanning and Segmentation in Fluorescently-labeled Tissues Using a Widefield High-content Analysis System.

    PubMed

    Poon, Candice C; Ebacher, Vincent; Liu, Katherine; Yong, Voon Wee; Kelly, John James Patrick

    2018-05-03

    Automated slide scanning and segmentation of fluorescently-labeled tissues is the most efficient way to analyze whole slides or large tissue sections. Unfortunately, many researchers spend large amounts of time and resources developing and optimizing workflows that are only relevant to their own experiments. In this article, we describe a protocol that can be used by those with access to a widefield high-content analysis system (WHCAS) to image any slide-mounted tissue, with options for customization within pre-built modules found in the associated software. Not originally intended for slide scanning, the steps detailed in this article make it possible to acquire slide scanning images in the WHCAS which can be imported into the associated software. In this example, the automated segmentation of brain tumor slides is demonstrated, but the automated segmentation of any fluorescently-labeled nuclear or cytoplasmic marker is possible. Furthermore, there are a variety of other quantitative software modules including assays for protein localization/translocation, cellular proliferation/viability/apoptosis, and angiogenesis that can be run. This technique will save researchers time and effort and create an automated protocol for slide analysis.

  8. Integrated fiducial sample mount and software for correlated microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Timothy R McJunkin; Jill R. Scott; Tammy L. Trowbridge

    2014-02-01

    A novel design sample mount with integrated fiducials and software for assisting operators in easily and efficiently locating points of interest established in previous analytical sessions is described. The sample holder and software were evaluated with experiments to demonstrate the utility and ease of finding the same points of interest in two different microscopy instruments. Also, numerical analysis of expected errors in determining the same position with errors unbiased by a human operator was performed. Based on the results, issues related to acquiring reproducibility and best practices for using the sample mount and software were identified. Overall, the sample mountmore » methodology allows data to be efficiently and easily collected on different instruments for the same sample location.« less

  9. Comparison of mounting methods for the evaluation of fibers by phase contrast microscopy.

    PubMed

    Lee, Eun Gyung; Pang, Thomas W S; Nelson, John; Andrew, Mike; Harper, Martin

    2011-07-01

    The objectives of this study were to evaluate mounting methods for fiber examination of air sample filters by phase contrast microscopy (PCM) and to evaluate differences in fiber counts that might be due to fiber movement. Acetone/triacetin (AT) with various amounts of triacetin and acetone/Euparal (AE) where the mounting medium was placed between the cleared filter wedge and the coverslip were tested as a function of time. Field sample slides collected from a taconite iron-ore processing mill, a tremolitic talc-ore processing mill, and from around a crusher in a meta-basalt stone quarry were prepared with relocatable coverslips to revisit the same field areas on the slides. For each slide, three or four field areas were randomly selected and pictures were taken every 2 weeks to determine any sign of fiber movement over time. For 11 AT slides (named as AT-3.5) prepared with 3.5 μl of the mounting medium according to the NIOSH 7400 method, no fiber movements were detected over 59 weeks. On the other hand, AT slides prepared with larger quantities (10, 15, and 20 μl) of the mounting medium (named as AT-10) and AE slides prepared with ∼10 μl mounting medium showed fiber movement from the eighth day at the earliest. Fiber movement began earlier for the slides mounted with excess triacetin than for those mounted with Euparal. The sample slide storage method, either vertically or horizontally, did not seem to accelerate fiber movement. Additionally, two other modified methods, dimethylformamide solution/Euparal (mDE) and dimethylformamide solution/triacetin (mDT), were also prepared where the mounting medium was placed between the cleared filter wedge and the glass slide. The findings of fiber movements were similar; when 3.5 μl of triacetin was used for the mDT slides, fiber movements were not detected, while fibers on slides prepared with 10 μl triacetin (mDT-10) moved around. No fiber movements were observed for the mDE slides at any time during 59 weeks. Once fiber movement started, fibers moved over distances measured from 4 μm and up to >1000 μm within 22 weeks. However, since then, no further fiber movements have been observed in any field sample slides. Additional sample slides, two Amosite and two chrysotile, were prepared from Union for International Cancer Control (UICC) samples using the AT method with 5 μl triacetin mounting medium. Fiber movements were also observed in these samples; chrysotile fibers began to migrate in 3 weeks, while Amosite fiber movement started after 3 months. Although fiber movement was observed for the AT-10, AE, and mDT-10 sample slides, fiber counts were not significantly different from AT-3.5 and mDE samples that exhibited no fiber movement. Although fiber counts would not be significantly changed by fiber movement, the type and amount of mounting medium for sample slide preparation remains critical for issues such as quality assurance and training of analysts by revisiting the same fibers.

  10. Fully automated three-dimensional microscopy system

    NASA Astrophysics Data System (ADS)

    Kerschmann, Russell L.

    2000-04-01

    Tissue-scale structures such as vessel networks are imaged at micron resolution with the Virtual Tissue System (VT System). VT System imaging of cubic millimeters of tissue and other material extends the capabilities of conventional volumetric techniques such as confocal microscopy, and allows for the first time the integrated 2D and 3D analysis of important tissue structural relationships. The VT System eliminates the need for glass slide-mounted tissue sections and instead captures images directly from the surface of a block containing a sample. Tissues are en bloc stained with fluorochrome compounds, embedded in an optically conditioned polymer that suppresses image signals form dep within the block , and serially sectioned for imaging. Thousands of fully registered 2D images are automatically captured digitally to completely convert tissue samples into blocks of high-resolution information. The resulting multi gigabyte data sets constitute the raw material for precision visualization and analysis. Cellular function may be seen in a larger anatomical context. VT System technology makes tissue metrics, accurate cell enumeration and cell cycle analyses possible while preserving full histologic setting.

  11. Tips on hybridizing, washing, and scanning affymetrix microarrays.

    PubMed

    Ares, Manuel

    2014-02-01

    Starting in the late 1990s, Affymetrix, Inc. produced a commercial system for hybridizing, washing, and scanning microarrays that was designed to be easy to operate and reproducible. The system used arrays packaged in a plastic cassette or chamber in which the prefabricated array was mounted and could be filled with fluid through resealable membrane ports either by hand or by an automated "fluidics station" specially designed to handle the arrays. A special rotating hybridization oven and a specially designed scanner were also required. Primarily because of automation and standardization the Affymetrix system was and still remains popular. Here, we provide a skeleton protocol with the potential pitfalls identified. It is designed to augment the protocols provided by Affymetrix.

  12. Remote observations with FLUOR and the CHARA Array

    NASA Astrophysics Data System (ADS)

    Merand, Antoine; Birlan, Mirel; Lelu de Brach, Remi; Coudé du Foresto, Vincent

    2004-10-01

    Two years ago, the FLUOR interferometric beam combiner moved from IOTA (Infrared Optical Telescopes Array, Mount Hopkins, AZ) to the Center for High Angular Resolution Astronomy (CHARA) Array (Mount Wilson, CA). Apart from offering the largest baselines in the northern hemisphere, this array can be fully operated remotely to allow observations from a distant place. We present here the automations added to the FLUOR hardware, as well as software modifications made in order to allow us to observe from Paris Observatory. We required the remote service to be as reactive as local observations, implying frequent communications between the instrument and the remote observer. We took particular attention to the available bandwidth and reactivity imposed by the secured connection (Virtual Private Network). The first tests are presented.

  13. First Sampling Hole in Mount Sharp

    NASA Image and Video Library

    2014-09-25

    This image from the Mars Hand Lens Imager MAHLI camera on NASA Curiosity Mars rover shows the first sample-collection hole drilled in Mount Sharp, the layered mountain that is the science destination of the rover extended mission.

  14. Manual versus automated blood sampling: impact of repeated blood sampling on stress parameters and behavior in male NMRI mice

    PubMed Central

    Kalliokoski, Otto; Sørensen, Dorte B; Hau, Jann; Abelson, Klas S P

    2014-01-01

    Facial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups. Plasma corticosterone levels of mice subjected to tail blood sampling were also elevated, although less significantly. Mice subjected to automated blood sampling were less affected with regard to the parameters measured, and expressed less anxious behavior. We conclude that repeated blood sampling by automated blood sampling and from the tail vein is less stressful than cheek blood sampling. The choice between automated blood sampling and tail blood sampling should be based on the study requirements, the resources of the laboratory and skills of the staff. PMID:24958546

  15. Development of an Automated Impact Hammer for Modal Analysis of Structures

    DTIC Science & Technology

    2012-02-01

    6 3.5 Integration with FBG interrogation system . . . . . . . . . . . . . . . . . 7 4 Experimental...distributed Fibre Bragg Gratings ( FBGs ) in optical fibres. The modified approach to SIDER has been given the name iSIDER or inverse SIDER to reflect the...response is measured at many locations using a large array of surface mounted FBG strain sensors [2]. FBGs are ideally suited to the roving response approach

  16. Design, Operation, and Maintenance of the Automated Rotation Control System for the 2.5-Meter Observa-Dome

    DTIC Science & Technology

    2013-02-01

    R MC32705 MultiComp Fan blade/ finger guard S SC181808NK Weigmann (Hubbell) 18 x 18 x 8 inch NEMA 1 enclosure, screw cover junction box or pull...box, no knockouts, wall mount T WGNDKT Weigmann (Hubbell) Field Grounding Kit, required for CSA on RSC ( NEMA 3R) and SC ( NEMA 1) series enclosures

  17. Solar-heated and cooled savings and loan building-1-Leavenworth, Kanasas

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Report describes heating and cooling system which furnishes 90 percent of annual heating load, 70 percent of cooling load, and all hot water for two-story building. Roof-mounted flat-plate collectors allow three distinct flow rates and are oriented south for optimum energy collection. Building contains fully automated temperature controls is divided into five temperature-load zones, each with independent heat pump.

  18. IEMIS (Integrated Emergency Management Information System) Floodplain Mapping Based on a Lidar Derived Data Set.

    DTIC Science & Technology

    1988-02-05

    0-A193 971 IEMIS (INTEGRATED EMERGENCY MANAGEMENT INFORMATION SYSTEM ) FLOODPLRIN MAP.. (U) ARMY ENGINEER WATERWAYS EXPERIMENT STATION VICKSBURG HS J...illustrate the application of the automated mapping capabilities of the Integrated Emergency Management Information System (IEMIS) to FISs. Unclassified...mapping capabilities of the Integrated Emergency Management Information System (IEMIS) to FISs. II. BACKGROUND The concept of mounting laser ranging

  19. Graywater Discharges from Vessels

    DTIC Science & Technology

    2011-11-01

    soaps and detergents used in any capacity that will be discharged as part of graywater must be nontoxic and phosphate -free, and should be...mounted on one skid. The Evac MBR process is fully automated and controlled through a PLC. Evac uses high quality Kubota membranes. Kubota membranes...the best solution. • Non- corrosive . By choosing to use non- corrosive materials (including a special space age polymer yielding strength and

  20. Concentration determination of nucleic acids and proteins using the micro-volume BioSpec-nano-spectrophotometer.

    PubMed

    Sukumaran, Suja

    2011-02-17

    Nucleic acid quantitation procedures have advanced significantly in the last three decades. More and more, molecular biologists require consistent small-volume analysis of nucleic acid samples for their experiments. The BioSpec-nano provides a potential solution to the problems of inaccurate, non-reproducible results, inherent in current DNA quantitation methods, via specialized optics and a sensitive PDA detector. The BioSpec-nano also has automated functionality such that mounting, measurement, and cleaning are done by the instrument, thereby eliminating tedious, repetitive, and inconsistent placement of the fiber optic element and manual cleaning. In this study, data is presented on the quantification of DNA and protein, as well as on measurement reproducibility and accuracy. Automated sample contact and rapid scanning allows measurement in three seconds, resulting in excellent throughput. Data analysis is carried out using the built-in features of the software. The formula used for calculating DNA concentration is: Sample Concentration = DF · (OD260-OD320)· NACF (1) Where DF = sample dilution factor and NACF = nucleic acid concentration factor. The Nucleic Acid concentration factor is set in accordance with the analyte selected. Protein concentration results can be expressed as μg/mL or as moles/L by entering e280 and molecular weight values respectively. When residue values for Tyr, Trp and Cysteine (S-S bond) are entered in the e280Calc tab, the extinction coefficient values are calculated as e280 = 5500 x (Trp residues) + 1490 x (Tyr residues) + 125 x (cysteine S-S bond). The e280 value is used by the software for concentration calculation. In addition to concentration determination of nucleic acids and protein, the BioSpec-nano can be used as an ultra micro-volume spectrophotometer for many other analytes or as a standard spectrophotometer using 5 mm pathlength cells.

  1. Concentration Determination of Nucleic Acids and Proteins Using the Micro-volume Bio-spec Nano Spectrophotometer

    PubMed Central

    Sukumaran, Suja

    2011-01-01

    Nucleic Acid quantitation procedures have advanced significantly in the last three decades. More and more, molecular biologists require consistent small-volume analysis of nucleic acid samples for their experiments. The BioSpec-nano provides a potential solution to the problems of inaccurate, non-reproducible results, inherent in current DNA quantitation methods, via specialized optics and a sensitive PDA detector. The BioSpec-nano also has automated functionality such that mounting, measurement, and cleaning are done by the instrument, thereby eliminating tedious, repetitive, and inconsistent placement of the fiber optic element and manual cleaning. In this study, data is presented on the quantification of DNA and protein, as well as on measurement reproducibility and accuracy. Automated sample contact and rapid scanning allows measurement in three seconds, resulting in excellent throughput. Data analysis is carried out using the built-in features of the software. The formula used for calculating DNA concentration is: Sample Concentration = DF · (OD260-OD320)· NACF (1) Where DF = sample dilution factor and NACF = nucleic acid concentration factor. The Nucleic Acid concentration factor is set in accordance with the analyte selected1. Protein concentration results can be expressed as μg/ mL or as moles/L by entering e280 and molecular weight values respectively. When residue values for Tyr, Trp and Cysteine (S-S bond) are entered in the e280Calc tab, the extinction coefficient values are calculated as e280 = 5500 x (Trp residues) + 1490 x (Tyr residues) + 125 x (cysteine S-S bond). The e280 value is used by the software for concentration calculation. In addition to concentration determination of nucleic acids and protein, the BioSpec-nano can be used as an ultra micro-volume spectrophotometer for many other analytes or as a standard spectrophotometer using 5 mm pathlength cells. PMID:21372788

  2. OMNY PIN—A versatile sample holder for tomographic measurements at room and cryogenic temperatures

    NASA Astrophysics Data System (ADS)

    Holler, M.; Raabe, J.; Wepf, R.; Shahmoradian, S. H.; Diaz, A.; Sarafimov, B.; Lachat, T.; Walther, H.; Vitins, M.

    2017-11-01

    Nowadays ptychographic tomography in the hard x-ray regime, i.e., at energies above about 2 keV, is a well-established measurement technique. At the Paul Scherrer Institut, currently two instruments are available: one is measuring at room temperature and atmospheric pressure, and the other, the so-called OMNY (tOMography Nano crYo) instrument, is operating at ultra-high vacuum and offering cryogenic sample temperatures down to 10 K. In this manuscript, we present the sample mounts that were developed for these instruments. Aside from excellent mechanical stability and thermal conductivity, they also offer highly reproducible mounting. Various types were developed for different kinds of samples and are presented in detail, including examples of how specimens can be mounted on these holders. We also show the first hard x-ray ptychographic tomography measurements of high-pressure frozen biological samples, in the present case Chlamydomonas cells, the related sample pins and preparation steps. For completeness, we present accessories such as transportation containers for both room temperature and cryogenic samples and a gripper mechanism for automatic sample changing. The sample mounts are not limited to x-ray tomography or hard x-ray energies, and we believe that they can be very useful for other instrumentation projects.

  3. Description and Applications for an Automated Inertial Azimuth Measuring System,

    DTIC Science & Technology

    specialized field environment. The present system consists of two integrated inertial sensors , an angle transfer system, a tiltmeter array and a...optical path. Highly sensitive tiltmeters are used to measure and correct for errors due to base motions of the inertial sensors . Data handling and...microprocessor. The inertial sensors use gimbal-mounted rate gyrocompasses to indicate the azimuths of two transfer mirrors with respect to true North. The

  4. Distributed Automated Medical Robotics to Improve Medical Field Operations

    DTIC Science & Technology

    2010-04-01

    ROBOT PATIENT INTERFACE Robotic trauma diagnosis and intervention is performed using instruments and tools mounted on the end of a robotic manipulator...manipulator to respond quickly enough to accommodate for motion due to high inertia and inaccuracies caused by low stiffness at the tool point. Ultrasonic...program was licensed to Intuitive Surgical, Inc and subsequently morphed into the daVinci surgical system. The daVinci has been widely applied in

  5. Automated Carrier Landing of an Unmanned Combat Aerial Vehicle Using Dynamic Inversion

    DTIC Science & Technology

    2007-06-01

    17 CN normal force coefficient . . . . . . . . . . . . . . . . . . . . 17 CA axial force coefficient...slug·ft2 Ixzb 0 slug·ft2 The aircraft has a single engine inlet for a single, centerline mounted turbofan engine. For purposes of this research, the...assumed to remain constant for each simulation run and were based on an assumed 10% fuel load with full weapons [2]. The rest of these values were

  6. Earth Observations taken by the Expedition 31 Crew

    NASA Image and Video Library

    2012-06-02

    ISS031-E-83747 (2 June 2012) --- Downlinked from the International Space Station this still image -– part of a series from a mounted, automated, twilight session -- when viewed in sequence shows the flame ring associated with wild fires in the Southwest move from bottom to top-center framed at a distance by the bright urban areas of Tucson, Phoenix, El Paso-Las Cruces, and finally Albuquerque (mostly under cloud).

  7. Earth Observations taken by the Expedition 31 Crew

    NASA Image and Video Library

    2012-06-02

    ISS031-E-83789 (2 June 2012) --- Downlinked from the International Space Station this still image – part of a series from a mounted, automated, twilight session -- when viewed in sequence shows the flame ring associated with wild fires in the Southwest move from bottom to top-center framed at a distance by the bright urban areas of Tucson, Phoenix, El Paso-Las Cruces, and finally Albuquerque (mostly under cloud).

  8. Development and operation of a high-throughput accurate-wavelength lens-based spectrometer a)

    DOE PAGES

    Bell, Ronald E.

    2014-07-11

    A high-throughput spectrometer for the 400-820 nm wavelength range has been developed for charge exchange recombination spectroscopy or general spectroscopy. A large 2160 mm -1 grating is matched with fast f /1.8 200 mm lenses, which provide stigmatic imaging. A precision optical encoder measures the grating angle with an accuracy ≤ 0.075 arc seconds. A high quantum efficiency low-etaloning CCD detector allows operation at longer wavelengths. A patch panel allows input fibers to interface with interchangeable fiber holders that attach to a kinematic mount behind the entrance slit. The computer-controlled hardware allows automated control of wavelength, timing, f-number, automated datamore » collection, and wavelength calibration.« less

  9. Study of sample drilling techniques for Mars sample return missions

    NASA Technical Reports Server (NTRS)

    Mitchell, D. C.; Harris, P. T.

    1980-01-01

    To demonstrate the feasibility of acquiring various surface samples for a Mars sample return mission the following tasks were performed: (1) design of a Mars rover-mounted drill system capable of acquiring crystalline rock cores; prediction of performance, mass, and power requirements for various size systems, and the generation of engineering drawings; (2) performance of simulated permafrost coring tests using a residual Apollo lunar surface drill, (3) design of a rock breaker system which can be used to produce small samples of rock chips from rocks which are too large to return to Earth, but too small to be cored with the Rover-mounted drill; (4)design of sample containers for the selected regolith cores, rock cores, and small particulate or rock samples; and (5) design of sample handling and transfer techniques which will be required through all phase of sample acquisition, processing, and stowage on-board the Earth return vehicle. A preliminary design of a light-weight Rover-mounted sampling scoop was also developed.

  10. Fluorescent Staining of Tea Pathogenic Fungi in Tea Leaves Using Fluorescein-labeled Lectin

    NASA Astrophysics Data System (ADS)

    Yamada, Kengo; Yoshida, Katsuyuki; Sonoda, Ryoichi

    Fluorochrome-labeled lectin, fluorescein conjugated wheat germ agglutinin (F-WGA) was applied to stain tea pathogenic fungi in tea leaf tissue. Infected leaves were fixed and decolorized with a mixture of ethanol and acetic acid, and cleared with 10% KOH for whole mount before staining with F-WGA. Hyphae of Pestalotiopsis longiseta, Pseudocercospora ocellata, Botrytis cinerea and Colletotrichum theae-sinensis fluoresced brightly in whole mount and sectioned samples of infected leaf tissue. In browned tissue, hyphae did not fluoresce frequently in whole mount sample. Autofluorescence of leaf tissue was strong in browned tissue of sections, it was removed by 10% KOH treatment before staining. Penetration hyphae of C. theae-sinensis in cell wall of trichome and hyphae in basal part of trichome did not fluoresced frequently. In whole mount samples of tea leaf infected with Exobasidium vexans and E. reticulatum, hymenia appeared on leaf surface fluoresced, but hyphae in leaf tissue did not fluoresce. In sectioned samples, hyphae fluoresced brightly when sections were treated with 10% KOH before staining.

  11. A Fractal Dimension Survey of Active Region Complexity

    NASA Technical Reports Server (NTRS)

    McAteer, R. T. James; Gallagher, Peter; Ireland, Jack

    2005-01-01

    A new approach to quantifying the magnetic complexity of active regions using a fractal dimension measure is presented. This fully-automated approach uses full disc MDI magnetograms of active regions from a large data set (2742 days of the SoHO mission; 9342 active regions) to compare the calculated fractal dimension to both Mount Wilson classification and flare rate. The main Mount Wilson classes exhibit no distinct fractal dimension distribution, suggesting a self-similar nature of all active regions. Solar flare productivity exhibits an increase in both the frequency and GOES X-ray magnitude of flares from regions with higher fractal dimensions. Specifically a lower threshold fractal dimension of 1.2 and 1.25 exists as a necessary, but not sufficient, requirement for an active region to produce M- and X-class flares respectively .

  12. Automated PCR setup for forensic casework samples using the Normalization Wizard and PCR Setup robotic methods.

    PubMed

    Greenspoon, S A; Sykes, K L V; Ban, J D; Pollard, A; Baisden, M; Farr, M; Graham, N; Collins, B L; Green, M M; Christenson, C C

    2006-12-20

    Human genome, pharmaceutical and research laboratories have long enjoyed the application of robotics to performing repetitive laboratory tasks. However, the utilization of robotics in forensic laboratories for processing casework samples is relatively new and poses particular challenges. Since the quantity and quality (a mixture versus a single source sample, the level of degradation, the presence of PCR inhibitors) of the DNA contained within a casework sample is unknown, particular attention must be paid to procedural susceptibility to contamination, as well as DNA yield, especially as it pertains to samples with little biological material. The Virginia Department of Forensic Science (VDFS) has successfully automated forensic casework DNA extraction utilizing the DNA IQ(trade mark) System in conjunction with the Biomek 2000 Automation Workstation. Human DNA quantitation is also performed in a near complete automated fashion utilizing the AluQuant Human DNA Quantitation System and the Biomek 2000 Automation Workstation. Recently, the PCR setup for casework samples has been automated, employing the Biomek 2000 Automation Workstation and Normalization Wizard, Genetic Identity version, which utilizes the quantitation data, imported into the software, to create a customized automated method for DNA dilution, unique to that plate of DNA samples. The PCR Setup software method, used in conjunction with the Normalization Wizard method and written for the Biomek 2000, functions to mix the diluted DNA samples, transfer the PCR master mix, and transfer the diluted DNA samples to PCR amplification tubes. Once the process is complete, the DNA extracts, still on the deck of the robot in PCR amplification strip tubes, are transferred to pre-labeled 1.5 mL tubes for long-term storage using an automated method. The automation of these steps in the process of forensic DNA casework analysis has been accomplished by performing extensive optimization, validation and testing of the software methods.

  13. Advantages and challenges in automated apatite fission track counting

    NASA Astrophysics Data System (ADS)

    Enkelmann, E.; Ehlers, T. A.

    2012-04-01

    Fission track thermochronometer data are often a core element of modern tectonic and denudation studies. Soon after the development of the fission track methods interest emerged for the developed an automated counting procedure to replace the time consuming labor of counting fission tracks under the microscope. Automated track counting became feasible in recent years with increasing improvements in computer software and hardware. One such example used in this study is the commercial automated fission track counting procedure from Autoscan Systems Pty that has been highlighted through several venues. We conducted experiments that are designed to reliably and consistently test the ability of this fully automated counting system to recognize fission tracks in apatite and a muscovite external detector. Fission tracks were analyzed in samples with a step-wise increase in sample complexity. The first set of experiments used a large (mm-size) slice of Durango apatite cut parallel to the prism plane. Second, samples with 80-200 μm large apatite grains of Fish Canyon Tuff were analyzed. This second sample set is characterized by complexities often found in apatites in different rock types. In addition to the automated counting procedure, the same samples were also analyzed using conventional counting procedures. We found for all samples that the fully automated fission track counting procedure using the Autoscan System yields a larger scatter in the fission track densities measured compared to conventional (manual) track counting. This scatter typically resulted from the false identification of tracks due surface and mineralogical defects, regardless of the image filtering procedure used. Large differences between track densities analyzed with the automated counting persisted between different grains analyzed in one sample as well as between different samples. As a result of these differences a manual correction of the fully automated fission track counts is necessary for each individual surface area and grain counted. This manual correction procedure significantly increases (up to four times) the time required to analyze a sample with the automated counting procedure compared to the conventional approach.

  14. Small Libraries Online: Automating Circulation and Public Access Catalogs. Participant Workbook.

    ERIC Educational Resources Information Center

    Garcia, C. Rebecca; Bridge, Frank R.

    This workbook, meant to be used in a workshop, presents information on and guidelines for automating small libraries: (1) planning for automation; (2) automated system procurement and evaluation; (3) data conversion issues; (4) sample configuration worksheets; (5) sample configuration costs; (6) site preparation; (7) training; and (8) acceptance…

  15. FlexED8: the first member of a fast and flexible sample-changer family for macromolecular crystallography.

    PubMed

    Papp, Gergely; Felisaz, Franck; Sorez, Clement; Lopez-Marrero, Marcos; Janocha, Robert; Manjasetty, Babu; Gobbo, Alexandre; Belrhali, Hassan; Bowler, Matthew W; Cipriani, Florent

    2017-10-01

    Automated sample changers are now standard equipment for modern macromolecular crystallography synchrotron beamlines. Nevertheless, most are only compatible with a single type of sample holder and puck. Recent work aimed at reducing sample-handling efforts and crystal-alignment times at beamlines has resulted in a new generation of compact and precise sample holders for cryocrystallography: miniSPINE and NewPin [see the companion paper by Papp et al. (2017, Acta Cryst., D73, 829-840)]. With full data collection now possible within seconds at most advanced beamlines, and future fourth-generation synchrotron sources promising to extract data in a few tens of milliseconds, the time taken to mount and centre a sample is rate-limiting. In this context, a versatile and fast sample changer, FlexED8, has been developed that is compatible with the highly successful SPINE sample holder and with the miniSPINE and NewPin sample holders. Based on a six-axis industrial robot, FlexED8 is equipped with a tool changer and includes a novel open sample-storage dewar with a built-in ice-filtering system. With seven versatile puck slots, it can hold up to 112 SPINE sample holders in uni-pucks, or 252 miniSPINE or NewPin sample holders, with 36 samples per puck. Additionally, a double gripper, compatible with the SPINE sample holders and uni-pucks, allows a reduction in the sample-exchange time from 40 s, the typical time with a standard single gripper, to less than 5 s. Computer vision-based sample-transfer monitoring, sophisticated error handling and automatic error-recovery procedures ensure high reliability. The FlexED8 sample changer has been successfully tested under real conditions on a beamline.

  16. Polyport atmospheric gas sampler

    DOEpatents

    Guggenheim, S. Frederic

    1995-01-01

    An atmospheric gas sampler with a multi-port valve which allows for multi, sequential sampling of air through a plurality of gas sampling tubes mounted in corresponding gas inlet ports. The gas sampler comprises a flow-through housing which defines a sampling chamber and includes a gas outlet port to accommodate a flow of gases through the housing. An apertured sample support plate defining the inlet ports extends across and encloses the sampling chamber and supports gas sampling tubes which depend into the sampling chamber and are secured across each of the inlet ports of the sample support plate in a flow-through relation to the flow of gases through the housing during sampling operations. A normally closed stopper means mounted on the sample support plate and operatively associated with each of the inlet ports blocks the flow of gases through the respective gas sampling tubes. A camming mechanism mounted on the sample support plate is adapted to rotate under and selectively lift open the stopper spring to accommodate a predetermined flow of gas through the respective gas sampling tubes when air is drawn from the housing through the outlet port.

  17. An automation-assisted generic approach for biological sample preparation and LC-MS/MS method validation.

    PubMed

    Zhang, Jie; Wei, Shimin; Ayres, David W; Smith, Harold T; Tse, Francis L S

    2011-09-01

    Although it is well known that automation can provide significant improvement in the efficiency of biological sample preparation in quantitative LC-MS/MS analysis, it has not been widely implemented in bioanalytical laboratories throughout the industry. This can be attributed to the lack of a sound strategy and practical procedures in working with robotic liquid-handling systems. Several comprehensive automation assisted procedures for biological sample preparation and method validation were developed and qualified using two types of Hamilton Microlab liquid-handling robots. The procedures developed were generic, user-friendly and covered the majority of steps involved in routine sample preparation and method validation. Generic automation procedures were established as a practical approach to widely implement automation into the routine bioanalysis of samples in support of drug-development programs.

  18. Shallow water benthic imaging and substrate characterization using recreational-grade sidescan-sonar

    USGS Publications Warehouse

    Buscombe, Daniel D.

    2017-01-01

    In recent years, lightweight, inexpensive, vessel-mounted ‘recreational grade’ sonar systems have rapidly grown in popularity among aquatic scientists, for swath imaging of benthic substrates. To promote an ongoing ‘democratization’ of acoustical imaging of shallow water environments, methods to carry out geometric and radiometric correction and georectification of sonar echograms are presented, based on simplified models for sonar-target geometry and acoustic backscattering and attenuation in shallow water. Procedures are described for automated removal of the acoustic shadows, identification of bed-water interface for situations when the water is too turbid or turbulent for reliable depth echosounding, and for automated bed substrate classification based on singlebeam full-waveform analysis. These methods are encoded in an open-source and freely-available software package, which should further facilitate use of recreational-grade sidescan sonar, in a fully automated and objective manner. The sequential correction, mapping, and analysis steps are demonstrated using a data set from a shallow freshwater environment.

  19. Hyperspectral Imaging and K-Means Classification for Histologic Evaluation of Ductal Carcinoma In Situ.

    PubMed

    Khouj, Yasser; Dawson, Jeremy; Coad, James; Vona-Davis, Linda

    2018-01-01

    Hyperspectral imaging (HSI) is a non-invasive optical imaging modality that shows the potential to aid pathologists in breast cancer diagnoses cases. In this study, breast cancer tissues from different patients were imaged by a hyperspectral system to detect spectral differences between normal and breast cancer tissues. Tissue samples mounted on slides were identified from 10 different patients. Samples from each patient included both normal and ductal carcinoma tissue, both stained with hematoxylin and eosin stain and unstained. Slides were imaged using a snapshot HSI system, and the spectral reflectance differences were evaluated. Analysis of the spectral reflectance values indicated that wavelengths near 550 nm showed the best differentiation between tissue types. This information was used to train image processing algorithms using supervised and unsupervised data. The K-means method was applied to the hyperspectral data cubes, and successfully detected spectral tissue differences with sensitivity of 85.45%, and specificity of 94.64% with true negative rate of 95.8%, and false positive rate of 4.2%. These results were verified by ground-truth marking of the tissue samples by a pathologist. In the hyperspectral image analysis, the image processing algorithm, K-means, shows the greatest potential for building a semi-automated system that could identify and sort between normal and ductal carcinoma in situ tissues.

  20. Innovations in air sampling to detect plant pathogens

    PubMed Central

    West, JS; Kimber, RBE

    2015-01-01

    Many innovations in the development and use of air sampling devices have occurred in plant pathology since the first description of the Hirst spore trap. These include improvements in capture efficiency at relatively high air-volume collection rates, methods to enhance the ease of sample processing with downstream diagnostic methods and even full automation of sampling, diagnosis and wireless reporting of results. Other innovations have been to mount air samplers on mobile platforms such as UAVs and ground vehicles to allow sampling at different altitudes and locations in a short space of time to identify potential sources and population structure. Geographical Information Systems and the application to a network of samplers can allow a greater prediction of airborne inoculum and dispersal dynamics. This field of technology is now developing quickly as novel diagnostic methods allow increasingly rapid and accurate quantifications of airborne species and genetic traits. Sampling and interpretation of results, particularly action-thresholds, is improved by understanding components of air dispersal and dilution processes and can add greater precision in the application of crop protection products as part of integrated pest and disease management decisions. The applications of air samplers are likely to increase, with much greater adoption by growers or industry support workers to aid in crop protection decisions. The same devices are likely to improve information available for detection of allergens causing hay fever and asthma or provide valuable metadata for regional plant disease dynamics. PMID:25745191

  1. Comparison Between Conventional and Automated Techniques for Blood Grouping and Crossmatching: Experience from a Tertiary Care Centre.

    PubMed

    Bhagwat, Swarupa Nikhil; Sharma, Jayashree H; Jose, Julie; Modi, Charusmita J

    2015-01-01

    The routine immunohematological tests can be performed by automated as well as manual techniques. These techniques have advantages and disadvantages inherent to them. The present study aims to compare the results of manual and automated techniques for blood grouping and crossmatching so as to validate the automated system effectively. A total of 1000 samples were subjected to blood grouping by the conventional tube technique (CTT) and the automated microplate LYRA system on Techno TwinStation. A total of 269 samples (multitransfused patients and multigravida females) were compared for 927 crossmatches by the CTT in indirect antiglobulin phase against the column agglutination technique (CAT) performed on Techno TwinStation. For blood grouping, the study showed a concordance in results for 942/1000 samples (94.2%), discordance for 4/1000 (0.4%) samples and uninterpretable result for 54/1000 samples (5.4%). On resolution, the uninterpretable results reduced to 49/1000 samples (4.9%) with 951/1000 samples (95.1%) showing concordant results. For crossmatching, the automated CAT showed concordant results in 887/927 (95.6%) and discordant results in 3/927 (0.32%) crossmatches as compared to the CTT. Total 37/927 (3.9%) crossmatches were not interpretable by the automated technique. The automated system shows a high concordance of results with CTT and hence can be brought into routine use. However, the high proportion of uninterpretable results emphasizes on the fact that proper training and standardization are needed prior to its use.

  2. The forces and moments on airplane engine mounts

    NASA Technical Reports Server (NTRS)

    Donely, Philip

    1936-01-01

    A resume of the equations and formulas for the forces and moments on an aircraft-engine mount is presented. In addition, available experimental data have been included to permit the computation of these forces and moments. A sample calculation is made and compared with present design conditions for engine mounts.

  3. Error Analysis and Performance Data from an Automated Azimuth Measuring System,

    DTIC Science & Technology

    1981-02-17

    microprocessors, tape drives, input and i NM. A detailed error analysis of the output hardware, a dual-axis tiltmeter ystem and methods to improve...performance mounted on the azimuth gimbal of each ALS, and accuracy are presented. Discussion and six tiltmeters arranged on an optical includes selected...velocity air flowing through tubes along the optical paths to each target. 1 . Introduction Temperature sensors are located in each To accurately and

  4. Models for formation and choice of variants for organizing digital electronics manufacturing

    NASA Astrophysics Data System (ADS)

    Korshunov, G. I.; Lapkova, M. Y.; Polyakov, S. L.; Frolova, E. A.

    2018-03-01

    The directions of organizing digital electronics manufacturing are considered by the example of surface mount technology. The basic equipment choice has to include not only individual characteristics, but also mutual influence of individual machines and the results of design for manufacturing. Application of special cases of the Utility function which are complicated in the general representation of polynomial functions are proposed for estimation of product quality in a staged automation.

  5. Translations on Environmental Quality, Number 148

    DTIC Science & Technology

    1977-10-03

    Article 9. Designs for gas filtering installations must include the proper control and automation facilities as per articles 16 and 17. Article 10...mandatorily equipped with: 1. Locking armature at the gas entrance and exit with manual or remote control flanges for the installation of end-caps in...instruments shall be mounted on the control panel of the gas filtering system or the control panel for the technological process. Article 17. (1) The gas

  6. Automation of Die and Mold Polishing: A Preliminary Investigation

    DTIC Science & Technology

    1990-02-02

    Brittenham, B.S.M.E. The Ohio State University 1989 Master’s Examination Committees Approved by Taylan Altan Gary P. Maul Advisor College of Engineering...Corporation, Mount Prospect, Illinois, September 1989. 68. Showa Precision Machinery, Robo -Polisher, Model SMR-100, Showa Precision Machinery Catalog No...Abrasives." Wear, 18, No. 2 (1971), pp. 169-170. 132 Robo -Polisher, Hodel SHR-100. Showa Precision Hachinery Catalog No. August 88-4000. Amagasaki, Japan

  7. A generic template for automated bioanalytical ligand-binding assays using modular robotic scripts in support of discovery biotherapeutic programs.

    PubMed

    Duo, Jia; Dong, Huijin; DeSilva, Binodh; Zhang, Yan J

    2013-07-01

    Sample dilution and reagent pipetting are time-consuming steps in ligand-binding assays (LBAs). Traditional automation-assisted LBAs use assay-specific scripts that require labor-intensive script writing and user training. Five major script modules were developed on Tecan Freedom EVO liquid handling software to facilitate the automated sample preparation and LBA procedure: sample dilution, sample minimum required dilution, standard/QC minimum required dilution, standard/QC/sample addition, and reagent addition. The modular design of automation scripts allowed the users to assemble an automated assay with minimal script modification. The application of the template was demonstrated in three LBAs to support discovery biotherapeutic programs. The results demonstrated that the modular scripts provided the flexibility in adapting to various LBA formats and the significant time saving in script writing and scientist training. Data generated by the automated process were comparable to those by manual process while the bioanalytical productivity was significantly improved using the modular robotic scripts.

  8. Mount control system of the ASTRI SST-2M prototype for the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Antolini, Elisa; Tosti, Gino; Tanci, Claudio; Bagaglia, Marco; Canestrari, Rodolfo; Cascone, Enrico; Gambini, Giorgio; Nucciarelli, Giuliano; Pareschi, Giovanni; Scuderi, Salvo; Stringhetti, Luca; Busatta, Andrea; Giacomel, Stefano; Marchiori, Gianpietro; Manfrin, Cristiana; Marcuzzi, Enrico; Di Michele, Daniele; Grigolon, Carlo; Guarise, Paolo

    2016-08-01

    The ASTRI SST-2M telescope is an end-to-end prototype proposed for the Small Size class of Telescopes (SST) of the future Cherenkov Telescope Array (CTA). The prototype is installed in Italy at the INAF observing station located at Serra La Nave on Mount Etna (Sicily) and it was inaugurated in September 2014. This paper presents the software and hardware architecture and development of the system dedicated to the control of the mount, health, safety and monitoring systems of the ASTRI SST-2M telescope prototype. The mount control system installed on the ASTRI SST-2M telescope prototype makes use of standard and widely deployed industrial hardware and software. State of the art of the control and automation industries was selected in order to fulfill the mount related functional and safety requirements with assembly compactness, high reliability, and reduced maintenance. The software package was implemented with the Beckhoff TwinCAT version 3 environment for the software Programmable Logical Controller (PLC), while the control electronics have been chosen in order to maximize the homogeneity and the real time performance of the system. The integration with the high level controller (Telescope Control System) has been carried out by choosing the open platform communications Unified Architecture (UA) protocol, supporting rich data model while offering compatibility with the PLC platform. In this contribution we show how the ASTRI approach for the design and implementation of the mount control system has made the ASTRI SST-2M prototype a standalone intelligent machine, able to fulfill requirements and easy to be integrated in an array configuration such as the future ASTRI mini-array proposed to be installed at the southern site of the Cherenkov Telescope Array (CTA).

  9. Light scattering by ultrasonically-controlled small particles: system design, calibration, and measurement results

    NASA Astrophysics Data System (ADS)

    Kassamakov, Ivan; Maconi, Göran; Penttilä, Antti; Helander, Petteri; Gritsevich, Maria; Puranen, Tuomas; Salmi, Ari; Hæggström, Edward; Muinonen, Karri

    2018-02-01

    We present the design of a novel scatterometer for precise measurement of the angular Mueller matrix profile of a mm- to µm-sized sample held in place by sound. The scatterometer comprises a tunable multimode Argon-krypton laser (with possibility to set 1 of the 12 wavelengths in visible range), linear polarizers, a reference photomultiplier tube (PMT) for monitoring the beam intensity, and a micro-PMT module mounted radially towards the sample at an adjustable radius. The measurement angle is controlled by a motor-driven rotation stage with an accuracy of 15'. The system is fully automated using LabVIEW, including the FPGA-based data acquisition and the instrument's user interface. The calibration protocol ensures accurate measurements by using a control sphere sample (diameter 3 mm, refractive index of 1.5) fixed first on a static holder followed by accurate multi-wavelength measurements of the same sample levitated ultrasonically. To demonstrate performance of the scatterometer, we conducted detailed measurements of light scattered by a particle derived from the Chelyabinsk meteorite, as well as planetary analogue materials. The measurements are the first of this kind, since they are obtained using controlled spectral angular scattering including linear polarization effects, for arbitrary shaped objects. Thus, our novel approach permits a non-destructive, disturbance-free measurement with control of the orientation and location of the scattering object.

  10. Multilayer mounting for long-term light sheet microscopy of zebrafish.

    PubMed

    Weber, Michael; Mickoleit, Michaela; Huisken, Jan

    2014-02-27

    Light sheet microscopy is the ideal imaging technique to study zebrafish embryonic development. Due to minimal photo-toxicity and bleaching, it is particularly suited for long-term time-lapse imaging over many hours up to several days. However, an appropriate sample mounting strategy is needed that offers both confinement and normal development of the sample. Multilayer mounting, a new embedding technique using low-concentration agarose in optically clear tubes, now overcomes this limitation and unleashes the full potential of light sheet microscopy for real-time developmental biology.

  11. Multilayer Mounting for Long-term Light Sheet Microscopy of Zebrafish

    PubMed Central

    Weber, Michael; Mickoleit, Michaela; Huisken, Jan

    2014-01-01

    Light sheet microscopy is the ideal imaging technique to study zebrafish embryonic development. Due to minimal photo-toxicity and bleaching, it is particularly suited for long-term time-lapse imaging over many hours up to several days. However, an appropriate sample mounting strategy is needed that offers both confinement and normal development of the sample. Multilayer mounting, a new embedding technique using low-concentration agarose in optically clear tubes, now overcomes this limitation and unleashes the full potential of light sheet microscopy for real-time developmental biology. PMID:24637614

  12. Automation--down to the nuts and bolts.

    PubMed

    Fix, R J; Rowe, J M; McConnell, B C

    2000-01-01

    Laboratories that once viewed automation as an expensive luxury are now looking to automation as a solution to increase sample throughput, to help ensure data integrity and to improve laboratory safety. The question is no longer, 'Should we automate?', but 'How should we approach automation?' A laboratory may choose from three approaches when deciding to automate: (1) contract with a third party vendor to produce a turnkey system, (2) develop and fabricate the system in-house or (3) some combination of approaches (1) and (2). The best approach for a given laboratory depends upon its available resources. The first lesson to be learned in automation is that no matter how straightforward an idea appears in the beginning, the solution will not be realized until many complex problems have been resolved. Issues dealing with sample vessel manipulation, liquid handling and system control must be addressed before a final design can be developed. This requires expertise in engineering, electronics, programming and chemistry. Therefore, the team concept of automation should be employed to help ensure success. This presentation discusses the advantages and disadvantages of the three approaches to automation. The development of an automated sample handling and control system for the STAR System focused microwave will be used to illustrate the complexities encountered in a seemingly simple project, and to highlight the importance of the team concept to automation no matter which approach is taken. The STAR System focused microwave from CEM Corporation is an open vessel digestion system with six microwave cells. This system is used to prepare samples for trace metal determination. The automated sample handling was developed around a XYZ motorized gantry system. Grippers were specially designed to perform several different functions and to provide feedback to the control software. Software was written in Visual Basic 5.0 to control the movement of the samples and the operation and monitoring of the STAR microwave. This software also provides a continuous update of the system's status to the computer screen. The system provides unattended preparation of up to 59 samples per run.

  13. Automated DBS microsampling, microscale automation and microflow LC-MS for therapeutic protein PK.

    PubMed

    Zhang, Qian; Tomazela, Daniela; Vasicek, Lisa A; Spellman, Daniel S; Beaumont, Maribel; Shyong, BaoJen; Kenny, Jacqueline; Fauty, Scott; Fillgrove, Kerry; Harrelson, Jane; Bateman, Kevin P

    2016-04-01

    Reduce animal usage for discovery-stage PK studies for biologics programs using microsampling-based approaches and microscale LC-MS. We report the development of an automated DBS-based serial microsampling approach for studying the PK of therapeutic proteins in mice. Automated sample preparation and microflow LC-MS were used to enable assay miniaturization and improve overall assay throughput. Serial sampling of mice was possible over the full 21-day study period with the first six time points over 24 h being collected using automated DBS sample collection. Overall, this approach demonstrated comparable data to a previous study using single mice per time point liquid samples while reducing animal and compound requirements by 14-fold. Reduction in animals and drug material is enabled by the use of automated serial DBS microsampling for mice studies in discovery-stage studies of protein therapeutics.

  14. Catch and Patch: A Pipette-Based Approach for Automating Patch Clamp That Enables Cell Selection and Fast Compound Application.

    PubMed

    Danker, Timm; Braun, Franziska; Silbernagl, Nikole; Guenther, Elke

    2016-03-01

    Manual patch clamp, the gold standard of electrophysiology, represents a powerful and versatile toolbox to stimulate, modulate, and record ion channel activity from membrane fragments and whole cells. The electrophysiological readout can be combined with fluorescent or optogenetic methods and allows for ultrafast solution exchanges using specialized microfluidic tools. A hallmark of manual patch clamp is the intentional selection of individual cells for recording, often an essential prerequisite to generate meaningful data. So far, available automation solutions rely on random cell usage in the closed environment of a chip and thus sacrifice much of this versatility by design. To parallelize and automate the traditional patch clamp technique while perpetuating the full versatility of the method, we developed an approach to automation, which is based on active cell handling and targeted electrode placement rather than on random processes. This is achieved through an automated pipette positioning system, which guides the tips of recording pipettes with micrometer precision to a microfluidic cell handling device. Using a patch pipette array mounted on a conventional micromanipulator, our automated patch clamp process mimics the original manual patch clamp as closely as possible, yet achieving a configuration where recordings are obtained from many patch electrodes in parallel. In addition, our implementation is extensible by design to allow the easy integration of specialized equipment such as ultrafast compound application tools. The resulting system offers fully automated patch clamp on purposely selected cells and combines high-quality gigaseal recordings with solution switching in the millisecond timescale.

  15. 4D (x-y-z-t) imaging of thick biological samples by means of Two-Photon inverted Selective Plane Illumination Microscopy (2PE-iSPIM)

    PubMed Central

    Lavagnino, Zeno; Sancataldo, Giuseppe; d’Amora, Marta; Follert, Philipp; De Pietri Tonelli, Davide; Diaspro, Alberto; Cella Zanacchi, Francesca

    2016-01-01

    In the last decade light sheet fluorescence microscopy techniques, such as selective plane illumination microscopy (SPIM), has become a well established method for developmental biology. However, conventional SPIM architectures hardly permit imaging of certain tissues since the common sample mounting procedure, based on gel embedding, could interfere with the sample morphology. In this work we propose an inverted selective plane microscopy system (iSPIM), based on non-linear excitation, suitable for 3D tissue imaging. First, the iSPIM architecture provides flexibility on the sample mounting, getting rid of the gel-based mounting typical of conventional SPIM, permitting 3D imaging of hippocampal slices from mouse brain. Moreover, all the advantages brought by two photon excitation (2PE) in terms of reduction of scattering effects and contrast improvement are exploited, demonstrating an improved image quality and contrast compared to single photon excitation. The system proposed represents an optimal platform for tissue imaging and it smooths the way to the applicability of light sheet microscopy to a wider range of samples including those that have to be mounted on non-transparent surfaces. PMID:27033347

  16. A flexible system to capture sample vials in a storage box - the box vial scanner.

    PubMed

    Nowakowski, Steven E; Kressin, Kenneth R; Deick, Steven D

    2009-01-01

    Tracking sample vials in a research environment is a critical task and doing so efficiently can have a large impact on productivity, especially in high volume laboratories. There are several challenges to automating the capture process, including the variety of containers used to store samples. We developed a fast and robust system to capture the location of sample vials being placed in storage that allows the laboratories the flexibility to use sample containers of varying dimensions. With a single scan, this device captures the box identifier, the vial identifier and the location of each vial within a freezer storage box. The sample vials are tracked through a barcode label affixed to the cap while the boxes are tracked by a barcode label on the side of the box. Scanning units are placed at the point of use and forward data to a sever application for processing the scanned data. Scanning units consist of an industrial barcode reader mounted in a fixture positioning the box for scanning and providing lighting during the scan. The server application transforms the scan data into a list of storage locations holding vial identifiers. The list is then transferred to the laboratory database. The box vial scanner captures the IDs and location information for an entire box of sample vials into the laboratory database in a single scan. The system accommodates a wide variety of vials sizes by inserting risers under the sample box and a variety of storage box layouts are supported via the processing algorithm on the server.

  17. An optical motion measuring system for laterally oscillated fatigue tests

    NASA Technical Reports Server (NTRS)

    Tripp, John S.; Tcheng, Ping; Murri, Gretchen B.; Sharpe, Scott

    1993-01-01

    This paper describes an optical system developed for materials testing laboratories at NASA Langley Research Center (LaRC) for high resolution monitoring of the transverse displacement and angular rotation of a test specimen installed in an axial-tension bending machine (ATB) during fatigue tests. It consists of a small laser, optics, a motorized mirror, three photodiodes, electronic detection and counting circuits, a data acquisition system, and a personal computer. A 3-inch by 5-inch rectangular plate attached to the upper grip of the test machine serves as a target base for the optical system. The personal computer automates the fatigue test procedure, controls data acquisition, performs data reduction, and provides user displays. The data acquisition system also monitors signals from up to 16 strain gages mounted on the test specimen. The motion measuring system is designed to continuously monitor and correlate the amplitude of the oscillatory motion with the strain gage signals in order to detect the onset of failure of the composite test specimen. A prototype system has been developed and tested which exceeds the design specifications of +/- 0.01 inch displacement accuracy, and +/- 0.25 deg angular accuracy at a sampling rate of 100 samples per second.

  18. Long duration ash probe

    DOEpatents

    Hurley, J.P.; McCollor, D.P.; Selle, S.J.

    1994-07-26

    A long duration ash probe includes a pressure shell connected to a port in a combustor with a sample coupon mounted on a retractable carriage so as to retract the sample coupon within the pressure shell during soot blowing operation of the combustor. A valve mounted at the forward end of the pressure shell is selectively closeable to seal the sample coupon within the shell, and a heating element in the shell is operable to maintain the desired temperature of the sample coupon while retracted within the shell. The carriage is operably mounted on a pair of rails within the shell for longitudinal movement within the shell. A hollow carrier tube connects the hollow cylindrical sample coupon to the carriage, and extends through the carriage and out the rearward end thereof. Air lines are connected to the rearward end of the carrier tube and are operable to permit coolant to pass through the air lines and thence through the carrier tube to the sample coupon so as to cool the sample coupon. 8 figs.

  19. Mars Technology Rover with Arm-Mounted Percussive Coring Tool, Microimager, and Sample-Handling Encapsulation Containerization Subsystem

    NASA Technical Reports Server (NTRS)

    Younse, Paulo J.; Dicicco, Matthew A.; Morgan, Albert R.

    2012-01-01

    A report describes the PLuto (programmable logic) Mars Technology Rover, a mid-sized FIDO (field integrated design and operations) class rover with six fully drivable and steerable cleated wheels, a rocker-bogey suspension, a pan-tilt mast with panorama and navigation stereo camera pairs, forward and rear stereo hazcam pairs, internal avionics with motor drivers and CPU, and a 5-degrees-of-freedom robotic arm. The technology rover was integrated with an arm-mounted percussive coring tool, microimager, and sample handling encapsulation containerization subsystem (SHEC). The turret of the arm contains a percussive coring drill and microimager. The SHEC sample caching system mounted to the rover body contains coring bits, sample tubes, and sample plugs. The coring activities performed in the field provide valuable data on drilling conditions for NASA tasks developing and studying coring technology. Caching of samples using the SHEC system provide insight to NASA tasks investigating techniques to store core samples in the future.

  20. Long duration ash probe

    DOEpatents

    Hurley, John P.; McCollor, Don P.; Selle, Stanley J.

    1994-01-01

    A long duration ash probe includes a pressure shell connected to a port in a combustor with a sample coupon mounted on a retractable carriage so as to retract the sample coupon within the pressure shell during sootblowing operation of the combustor. A valve mounted at the forward end of the pressure shell is selectively closeable to seal the sample coupon within the shell, and a heating element in the shell is operable to maintain the desired temperature of the sample coupon while retracted within the shell. The carriage is operably mounted on a pair of rails within the shell for longitudinal movement within the shell. A hollow carrier tube connects the hollow cylindrical sample coupon to the carriage, and extends through the carriage and out the rearward end thereof. Air lines are connected to the rearward end of the carrier tube and are operable to permit coolant to pass through the air lines and thence through the carrier tube to the sample coupon so as to cool the sample coupon.

  1. Gage for measuring displacements in rock samples

    DOEpatents

    Holcomb, D.J.; McNamee, M.J.

    1985-07-18

    A gage for measuring diametral displacement within a rock sample for use in a rock mechanics laboratory and in the field, comprises a support ring housing a linear variable differential transformer (LVDT), a mounting screw, and a leaf spring. The mounting screw is adjustable and defines a first point of contact with the rock sample. The leaf spring has opposite ends fixed to the inner periphery of the mounting ring. An intermediate portion of the leaf spring projecting radially inward from the ring is formed with a dimple defining a second point of contact with the sample. The first and second points of contact are diametrically opposed to each other. The LVDT is mounted in the ring with its axis parallel to the line of measurement and its core rod received in the dimple of the leaf spring. Any change in the length of the line between the first and second support points is directly communicated to the LVDT. The leaf spring is rigid to completely support lateral forces so that the LVDT is free of all load for improved precision.

  2. DNA barcoding and regional diversity of understudied Micropeplinae (Coleoptera: Staphylinidae) in Southwest China: phylogenetic implications and a new Micropeplus from Mount Emei.

    PubMed

    Grebennikov, Vasily V; Smetana, Aleš

    2015-02-18

    Extensive litter sampling at eight forested localities in Yunnan and Sichuan detected 381 specimens of Micropeplinae rove beetles. DNA barcoding data from 85 representative specimens were analysed to delimit species and infer their relationships. Statistical methods were implemented to assess regional species diversity of understudied Micropeplinae. The total number of sampled Micropeplinae species varied between 14 and 17, depending on a splitting versus lumping approach for allopatric populations. A single Micropeplinae species was sampled in six of eight studied localities, three species were found on Mount Gongga, while ten species were discovered on hyperdiverse Mount Emei in Sichuan. All Micropeplinae specimens from our samples belong either to the genus Cerapeplus, or to three other inclusive groups temporarily retained inside Micropeplus sensu lato. Each of the three groups potentially represents a separate genus: tesserula group, sculptus group and Micropeplus sensu stricto. A new species Micropeplus jason sp. n. from Mount Emei in Sichuan is described. Numerous illustrations introduce regional fauna and clarify the discussed morphological characters.

  3. Gage for measuring displacements in rock samples

    DOEpatents

    Holcomb, David J.; McNamee, Michael J.

    1986-01-01

    A gage for measuring diametral displacement within a rock sample for use in a rock mechanics laboratory and in the field, comprises a support ring housing a linear variable differential transformer, a mounting screw, and a leaf spring. The mounting screw is adjustable and defines a first point of contact with the rock sample. The leaf spring has opposite ends fixed to the inner periphery of the mounting ring. An intermediate portion of the leaf spring projecting radially inward from the ring is formed with a dimple defining a second point of contact with the sample. The first and second points of contact are diametrically opposed to each other. The LVDT is mounted in the ring with its axis parallel to the line of measurement and its core rod received in the dimple of the leaf spring. Any change in the length of the line between the first and second support points is directly communicated to the LVDT. The leaf spring is rigid to completely support lateral forces so that the LVDT is free of all load for improved precision.

  4. Automating spectral measurements

    NASA Astrophysics Data System (ADS)

    Goldstein, Fred T.

    2008-09-01

    This paper discusses the architecture of software utilized in spectroscopic measurements. As optical coatings become more sophisticated, there is mounting need to automate data acquisition (DAQ) from spectrophotometers. Such need is exacerbated when 100% inspection is required, ancillary devices are utilized, cost reduction is crucial, or security is vital. While instrument manufacturers normally provide point-and-click DAQ software, an application programming interface (API) may be missing. In such cases automation is impossible or expensive. An API is typically provided in libraries (*.dll, *.ocx) which may be embedded in user-developed applications. Users can thereby implement DAQ automation in several Windows languages. Another possibility, developed by FTG as an alternative to instrument manufacturers' software, is the ActiveX application (*.exe). ActiveX, a component of many Windows applications, provides means for programming and interoperability. This architecture permits a point-and-click program to act as automation client and server. Excel, for example, can control and be controlled by DAQ applications. Most importantly, ActiveX permits ancillary devices such as barcode readers and XY-stages to be easily and economically integrated into scanning procedures. Since an ActiveX application has its own user-interface, it can be independently tested. The ActiveX application then runs (visibly or invisibly) under DAQ software control. Automation capabilities are accessed via a built-in spectro-BASIC language with industry-standard (VBA-compatible) syntax. Supplementing ActiveX, spectro-BASIC also includes auxiliary serial port commands for interfacing programmable logic controllers (PLC). A typical application is automatic filter handling.

  5. Automated visual inspection system based on HAVNET architecture

    NASA Astrophysics Data System (ADS)

    Burkett, K.; Ozbayoglu, Murat A.; Dagli, Cihan H.

    1994-10-01

    In this study, the HAusdorff-Voronoi NETwork (HAVNET) developed at the UMR Smart Engineering Systems Lab is tested in the recognition of mounted circuit components commonly used in printed circuit board assembly systems. The automated visual inspection system used consists of a CCD camera, a neural network based image processing software and a data acquisition card connected to a PC. The experiments are run in the Smart Engineering Systems Lab in the Engineering Management Dept. of the University of Missouri-Rolla. The performance analysis shows that the vision system is capable of recognizing different components under uncontrolled lighting conditions without being effected by rotation or scale differences. The results obtained are promising and the system can be used in real manufacturing environments. Currently the system is being customized for a specific manufacturing application.

  6. Automation of the targeting and reflective alignment concept

    NASA Technical Reports Server (NTRS)

    Redfield, Robin C.

    1992-01-01

    The automated alignment system, described herein, employs a reflective, passive (requiring no power) target and includes a PC-based imaging system and one camera mounted on a six degree of freedom robot manipulator. The system detects and corrects for manipulator misalignment in three translational and three rotational directions by employing the Targeting and Reflective Alignment Concept (TRAC), which simplifies alignment by decoupling translational and rotational alignment control. The concept uses information on the camera and the target's relative position based on video feedback from the camera. These relative positions are converted into alignment errors and minimized by motions of the robot. The system is robust to exogenous lighting by virtue of a subtraction algorithm which enables the camera to only see the target. These capabilities are realized with relatively minimal complexity and expense.

  7. Effect of Er,Cr:YSGG laser on human dentin fluid flow.

    PubMed

    Al-Omari, Wael M; Palamara, Joseph E

    2013-11-01

    The aim of the current investigation was to assess the rate and magnitude of dentin fluid flow of dentinal surfaces irradiated with Er,Cr:YSGG laser. Twenty extracted third molars were sectioned, mounted, and irradiated with Er,Cr:YSGG laser at 3.5 and 4.5 W power settings. Specimens were connected to an automated fluid flow measurement apparatus (Flodec). The rate, magnitude, and direction of dentin fluid flow were recorded at baseline and after irradiation. Nonparametric Wilcoxon signed ranks repeated measure t test revealed a statistically significant reduction in fluid flow for all the power settings. The 4.5-W power output reduced the flow significantly more than the 3.5 W. The samples showed a baseline outward flow followed by inward flow due to irradiation then followed by decreased outward flow. It was concluded that Er,Cr:YSGG laser irradiation at 3.5 and 4.5 W significantly reduced dentinal fluid flow rate. The reduction was directly proportional to power output.

  8. Ambient airborne solids concentrations including volcanic ash at Hanford, Washington sampling sites subsequent to the Mount St. Helens eruption

    NASA Technical Reports Server (NTRS)

    Sehmel, G. A.

    1982-01-01

    Airborne solids concentrations were measured on a near daily basis at two Hanford, Washington sites after the eruption of Mount St. Helens on May 18, 1980. These sites are about 211 km east of Mount St. Helens. Collected airborne solids included resuspended volcanic ash plus normal ambient solids. Average airborne solids concentrations were greater at the Hanford meteorological station sampling site which is 24 km northwest of the Horn Rapids dam sampling site. These increased concentrations reflect the sampling site proximity to greater ash fallout depths. Both sites are in low ash fallout areas although the Hanford meteorological station site is closer to the greater ash fallout areas. Airborne solids concentrations were decreased by rain, but airborne solids concentrations rapidly increased as surfaces dried. Airborne concentrations tended to become nearly the same at both sampling sites only for July 12 and 13.

  9. Performance of Copan WASP for Routine Urine Microbiology

    PubMed Central

    Quiblier, Chantal; Jetter, Marion; Rominski, Mark; Mouttet, Forouhar; Böttger, Erik C.; Keller, Peter M.

    2015-01-01

    This study compared a manual workup of urine clinical samples with fully automated WASPLab processing. As a first step, two different inocula (1 and 10 μl) and different streaking patterns were compared using WASP and InoqulA BT instrumentation. Significantly more single colonies were produced with the10-μl inoculum than with the 1-μl inoculum, and automated streaking yielded significantly more single colonies than manual streaking on whole plates (P < 0.001). In a second step, 379 clinical urine samples were evaluated using WASP and the manual workup. Average numbers of detected morphologies, recovered species, and CFUs per milliliter of all 379 urine samples showed excellent agreement between WASPLab and the manual workup. The percentage of urine samples clinically categorized as positive or negative did not differ between the automated and manual workflow, but within the positive samples, automated processing by WASPLab resulted in the detection of more potential pathogens. In summary, the present study demonstrates that (i) the streaking pattern, i.e., primarily the number of zigzags/length of streaking lines, is critical for optimizing the number of single colonies yielded from primary cultures of urine samples; (ii) automated streaking by the WASP instrument is superior to manual streaking regarding the number of single colonies yielded (for 32.2% of the samples); and (iii) automated streaking leads to higher numbers of detected morphologies (for 47.5% of the samples), species (for 17.4% of the samples), and pathogens (for 3.4% of the samples). The results of this study point to an improved quality of microbiological analyses and laboratory reports when using automated sample processing by WASP and WASPLab. PMID:26677255

  10. Comparison Between Conventional and Automated Techniques for Blood Grouping and Crossmatching: Experience from a Tertiary Care Centre

    PubMed Central

    Bhagwat, Swarupa Nikhil; Sharma, Jayashree H; Jose, Julie; Modi, Charusmita J

    2015-01-01

    Context: The routine immunohematological tests can be performed by automated as well as manual techniques. These techniques have advantages and disadvantages inherent to them. Aims: The present study aims to compare the results of manual and automated techniques for blood grouping and crossmatching so as to validate the automated system effectively. Materials and Methods: A total of 1000 samples were subjected to blood grouping by the conventional tube technique (CTT) and the automated microplate LYRA system on Techno TwinStation. A total of 269 samples (multitransfused patients and multigravida females) were compared for 927 crossmatches by the CTT in indirect antiglobulin phase against the column agglutination technique (CAT) performed on Techno TwinStation. Results: For blood grouping, the study showed a concordance in results for 942/1000 samples (94.2%), discordance for 4/1000 (0.4%) samples and uninterpretable result for 54/1000 samples (5.4%). On resolution, the uninterpretable results reduced to 49/1000 samples (4.9%) with 951/1000 samples (95.1%) showing concordant results. For crossmatching, the automated CAT showed concordant results in 887/927 (95.6%) and discordant results in 3/927 (0.32%) crossmatches as compared to the CTT. Total 37/927 (3.9%) crossmatches were not interpretable by the automated technique. Conclusions: The automated system shows a high concordance of results with CTT and hence can be brought into routine use. However, the high proportion of uninterpretable results emphasizes on the fact that proper training and standardization are needed prior to its use. PMID:26417159

  11. MARS: bringing the automation of small-molecule bioanalytical sample preparations to a new frontier.

    PubMed

    Li, Ming; Chou, Judy; Jing, Jing; Xu, Hui; Costa, Aldo; Caputo, Robin; Mikkilineni, Rajesh; Flannelly-King, Shane; Rohde, Ellen; Gan, Lawrence; Klunk, Lewis; Yang, Liyu

    2012-06-01

    In recent years, there has been a growing interest in automating small-molecule bioanalytical sample preparations specifically using the Hamilton MicroLab(®) STAR liquid-handling platform. In the most extensive work reported thus far, multiple small-molecule sample preparation assay types (protein precipitation extraction, SPE and liquid-liquid extraction) have been integrated into a suite that is composed of graphical user interfaces and Hamilton scripts. Using that suite, bioanalytical scientists have been able to automate various sample preparation methods to a great extent. However, there are still areas that could benefit from further automation, specifically, the full integration of analytical standard and QC sample preparation with study sample extraction in one continuous run, real-time 2D barcode scanning on the Hamilton deck and direct Laboratory Information Management System database connectivity. We developed a new small-molecule sample-preparation automation system that improves in all of the aforementioned areas. The improved system presented herein further streamlines the bioanalytical workflow, simplifies batch run design, reduces analyst intervention and eliminates sample-handling error.

  12. Flexible automated approach for quantitative liquid handling of complex biological samples.

    PubMed

    Palandra, Joe; Weller, David; Hudson, Gary; Li, Jeff; Osgood, Sarah; Hudson, Emily; Zhong, Min; Buchholz, Lisa; Cohen, Lucinda H

    2007-11-01

    A fully automated protein precipitation technique for biological sample preparation has been developed for the quantitation of drugs in various biological matrixes. All liquid handling during sample preparation was automated using a Hamilton MicroLab Star Robotic workstation, which included the preparation of standards and controls from a Watson laboratory information management system generated work list, shaking of 96-well plates, and vacuum application. Processing time is less than 30 s per sample or approximately 45 min per 96-well plate, which is then immediately ready for injection onto an LC-MS/MS system. An overview of the process workflow is discussed, including the software development. Validation data are also provided, including specific liquid class data as well as comparative data of automated vs manual preparation using both quality controls and actual sample data. The efficiencies gained from this automated approach are described.

  13. Conductive carbon tape used for support and mounting of both whole animal and fragile heat-treated tissue sections for MALDI MS imaging and quantitation.

    PubMed

    Goodwin, Richard J A; Nilsson, Anna; Borg, Daniel; Langridge-Smith, Pat R R; Harrison, David J; Mackay, C Logan; Iverson, Suzanne L; Andrén, Per E

    2012-08-30

    Analysis of whole animal tissue sections by MALDI MS imaging (MSI) requires effective sample collection and transfer methods to allow the highest quality of in situ analysis of small or hard to dissect tissues. We report on the use of double-sided adhesive conductive carbon tape during whole adult rat tissue sectioning of carboxymethyl cellulose (CMC) embedded animals, with samples mounted onto large format conductive glass and conductive plastic MALDI targets, enabling MSI analysis to be performed on both TOF and FT-ICR MALDI mass spectrometers. We show that mounting does not unduly affect small molecule MSI detection by analyzing tiotropium abundance and distribution in rat lung tissues, with direct on-tissue quantitation achieved. Significantly, we use the adhesive tape to provide support to embedded delicate heat-stabilized tissues, enabling sectioning and mounting to be performed that maintained tissue integrity on samples that had previously been impossible to adequately prepare section for MSI analysis. The mapping of larger peptidomic molecules was not hindered by tape mounting samples and we demonstrate this by mapping the distribution of PEP-19 in both native and heat-stabilized rat brains. Furthermore, we show that without heat stabilization PEP-19 degradation fragments can detected and identified directly by MALDI MSI analysis. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Sample mounts for microcrystal crystallography

    NASA Technical Reports Server (NTRS)

    Thorne, Robert E. (Inventor); Kmetko, Jan (Inventor); Stum, Zachary (Inventor); O'Neill, Kevin (Inventor)

    2007-01-01

    Sample mounts (10) for mounting microcrystals of biological macromolecules for X-ray crystallography are prepared by using patterned thin polyimide films (12) that have curvature imparted thereto, for example, by being attached to a curved outer surface of a small metal rod (16). The patterned film (12) preferably includes a tapered tip end (24) for holding a crystal. Preferably, a small sample aperture is disposed in the film for reception of the crystal. A second, larger aperture can also be provided that is connected to the sample aperture by a drainage channel, allowing removal of excess liquid and easier manipulation in viscous solutions. The curvature imparted to the film (12) increases the film's rigidity and allows a convenient scoop-like action for retrieving crystals. The polyimide contributes minimally to background and absorption, and can be treated to obtain desired hydrophobicity or hydrophilicity.

  15. Sample mounts for microcrystal crystallography

    NASA Technical Reports Server (NTRS)

    O'Neill, Kevin (Inventor); Kmetko, Jan (Inventor); Thorne, Robert E. (Inventor); Stum, Zachary (Inventor)

    2009-01-01

    Sample mounts (10) for mounting microcrystals of biological macromolecules for X-ray crystallography are prepared by using patterned thin polyimide films (12) that have curvature imparted thereto, for example, by being attached to a curved outer surface of a small metal rod (16). The patterned film (12) preferably includes a tip end (24) for holding a crystal. Preferably, a small sample aperture is disposed in the film for reception of the crystal. A second, larger aperture can also be provided that is connected to the sample aperture by a drainage channel, allowing removal of excess liquid and easier manipulation in viscous solutions. The curvature imparted to the film (12) increases the film's rigidity and allows a convenient scoop-like action for retrieving crystals. The polyimide contributes minimally to background and absorption, and can be treated to obtain desired hydrophobicity or hydrophilicity.

  16. Towards Optimization of Macrocognitive Processes: Automating Analysis of the Emergence of Leadership in Ad Hoc Teams

    DTIC Science & Technology

    2014-04-21

    Journal of Sociotechnology and Knowledge Development (IJSKD), 4(3), 17-37. Anders S, Schweikhart S, Woods DD, Ebright P, Patterson ES. (2012) The Effects...Ergonomics Society, 282-286. • Patterson ES, Rayo MF, Weiss C, Woods Z, Mount-Campbell AF. Online Training for Resilience Communication Strategies during...Shift Change Handovers, in Proceedings of the Human Factors and Ergonomics Society Annual Meeting. (Sep 2013). 57 (1). 1427- 1431. Woods Z, Beecroft

  17. Integrating PCLIPS into ULowell's Lincoln Logs: Factory of the future

    NASA Technical Reports Server (NTRS)

    Mcgee, Brenda J.; Miller, Mark D.; Krolak, Patrick; Barr, Stanley J.

    1990-01-01

    We are attempting to show how independent but cooperating expert systems, executing within a parallel production system (PCLIPS), can operate and control a completely automated, fault tolerant prototype of a factory of the future (The Lincoln Logs Factory of the Future). The factory consists of a CAD system for designing the Lincoln Log Houses, two workcells, and a materials handling system. A workcell consists of two robots, part feeders, and a frame mounted vision system.

  18. Earth Observations taken by the Expedition 31 Crew

    NASA Image and Video Library

    2012-06-02

    ISS031-E-84006 (2 June 2012) --- This digital image from the Expedition 31 crew aboard the International Space Station is one of a series from a mounted, automated, and nighttime session of a still camera when viewed in sequence shows the flame-ring associated with wild fires in the Southwest slip by in the upper right while the lights of the El Paso-Las Cruces rise from bottom center. A Russian spacecraft is docked to the station

  19. Fast, Automated, Scalable Generation of Textured 3D Models of Indoor Environments

    DTIC Science & Technology

    2014-12-18

    expensive travel and on-site visits. Different applications require models of different complexities, both with and without furniture geometry. The...environment and to localize the system in the environment over time. The datasets shown in this paper were generated by a backpack -mounted system that uses 2D...voxel is found to intersect the line segment from a scanner to a corresponding scan point. If a laser passes through a voxel, that voxel is considered

  20. Automated composite ellipsoid modelling for high frequency GTD analysis

    NASA Technical Reports Server (NTRS)

    Sze, K. Y.; Rojas, R. G.; Klevenow, F. T.; Scheick, J. T.

    1991-01-01

    The preliminary results of a scheme currently being developed to fit a composite ellipsoid to the fuselage of a helicopter in the vicinity of the antenna location are discussed under the assumption that the antenna is mounted on the fuselage. The parameters of the close-fit composite ellipsoid would then be utilized as inputs into NEWAIR3, a code programmed in FORTRAN 77 for high frequency Geometrical Theory of Diffraction (GTD) Analysis of the radiation of airborne antennas.

  1. Automatic cell identification and visualization using digital holographic microscopy with head mounted augmented reality devices.

    PubMed

    O'Connor, Timothy; Rawat, Siddharth; Markman, Adam; Javidi, Bahram

    2018-03-01

    We propose a compact imaging system that integrates an augmented reality head mounted device with digital holographic microscopy for automated cell identification and visualization. A shearing interferometer is used to produce holograms of biological cells, which are recorded using customized smart glasses containing an external camera. After image acquisition, segmentation is performed to isolate regions of interest containing biological cells in the field-of-view, followed by digital reconstruction of the cells, which is used to generate a three-dimensional (3D) pseudocolor optical path length profile. Morphological features are extracted from the cell's optical path length map, including mean optical path length, coefficient of variation, optical volume, projected area, projected area to optical volume ratio, cell skewness, and cell kurtosis. Classification is performed using the random forest classifier, support vector machines, and K-nearest neighbor, and the results are compared. Finally, the augmented reality device displays the cell's pseudocolor 3D rendering of its optical path length profile, extracted features, and the identified cell's type or class. The proposed system could allow a healthcare worker to quickly visualize cells using augmented reality smart glasses and extract the relevant information for rapid diagnosis. To the best of our knowledge, this is the first report on the integration of digital holographic microscopy with augmented reality devices for automated cell identification and visualization.

  2. Development of a machine vision system for automated structural assembly

    NASA Technical Reports Server (NTRS)

    Sydow, P. Daniel; Cooper, Eric G.

    1992-01-01

    Research is being conducted at the LaRC to develop a telerobotic assembly system designed to construct large space truss structures. This research program was initiated within the past several years, and a ground-based test-bed was developed to evaluate and expand the state of the art. Test-bed operations currently use predetermined ('taught') points for truss structural assembly. Total dependence on the use of taught points for joint receptacle capture and strut installation is neither robust nor reliable enough for space operations. Therefore, a machine vision sensor guidance system is being developed to locate and guide the robot to a passive target mounted on the truss joint receptacle. The vision system hardware includes a miniature video camera, passive targets mounted on the joint receptacles, target illumination hardware, and an image processing system. Discrimination of the target from background clutter is accomplished through standard digital processing techniques. Once the target is identified, a pose estimation algorithm is invoked to determine the location, in three-dimensional space, of the target relative to the robots end-effector. Preliminary test results of the vision system in the Automated Structural Assembly Laboratory with a range of lighting and background conditions indicate that it is fully capable of successfully identifying joint receptacle targets throughout the required operational range. Controlled optical bench test results indicate that the system can also provide the pose estimation accuracy to define the target position.

  3. In-Situ Water Vapor Probe for a Robot Arm-Mounted, Compact Water Vapor Analyzer: Preliminary Results

    NASA Technical Reports Server (NTRS)

    Socki, Richard A.; Niles, Paul B.; Cabiran, Mike; Rossi, Chris; Sun, Tao

    2013-01-01

    This work describes the ongoing development of an instrument package for the in-situ detection and isotopic analysis of water (from ice, icy soils, and hydrated minerals) on future lunar, asteroid, or martian exploration missions. This instrument is intended to be mounted on a robotic arm and be brought to the sample, rather than necessitating expensive and complicated sample handling to bring the sample to the instrument.

  4. High-frequency, long-duration water sampling in acid mine drainage studies: a short review of current methods and recent advances in automated water samplers

    USGS Publications Warehouse

    Chapin, Thomas

    2015-01-01

    Hand-collected grab samples are the most common water sampling method but using grab sampling to monitor temporally variable aquatic processes such as diel metal cycling or episodic events is rarely feasible or cost-effective. Currently available automated samplers are a proven, widely used technology and typically collect up to 24 samples during a deployment. However, these automated samplers are not well suited for long-term sampling in remote areas or in freezing conditions. There is a critical need for low-cost, long-duration, high-frequency water sampling technology to improve our understanding of the geochemical response to temporally variable processes. This review article will examine recent developments in automated water sampler technology and utilize selected field data from acid mine drainage studies to illustrate the utility of high-frequency, long-duration water sampling.

  5. The Impact of Sampling Approach on Population Invariance in Automated Scoring of Essays. Research Report. ETS RR-13-18

    ERIC Educational Resources Information Center

    Zhang, Mo

    2013-01-01

    Many testing programs use automated scoring to grade essays. One issue in automated essay scoring that has not been examined adequately is population invariance and its causes. The primary purpose of this study was to investigate the impact of sampling in model calibration on population invariance of automated scores. This study analyzed scores…

  6. ℮-conome: an automated tissue counting platform of cone photoreceptors for rodent models of retinitis pigmentosa.

    PubMed

    Clérin, Emmanuelle; Wicker, Nicolas; Mohand-Saïd, Saddek; Poch, Olivier; Sahel, José-Alain; Léveillard, Thierry

    2011-12-20

    Retinitis pigmentosa is characterized by the sequential loss of rod and cone photoreceptors. The preservation of cones would prevent blindness due to their essential role in human vision. Rod-derived Cone Viability Factor is a thioredoxin-like protein that is secreted by rods and is involved in cone survival. To validate the activity of Rod-derived Cone Viability Factors (RdCVFs) as therapeutic agents for treating retinitis Pigmentosa, we have developed e-conome, an automated cell counting platform for retinal flat mounts of rodent models of cone degeneration. This automated quantification method allows for faster data analysis thereby accelerating translational research. An inverted fluorescent microscope, motorized and coupled to a CCD camera records images of cones labeled with fluorescent peanut agglutinin lectin on flat-mounted retinas. In an average of 300 fields per retina, nine Z-planes at magnification X40 are acquired after two-stage autofocus individually for each field. The projection of the stack of 9 images is subject to a threshold, filtered to exclude aberrant images based on preset variables. The cones are identified by treating the resulting image using 13 variables empirically determined. The cone density is calculated over the 300 fields. The method was validated by comparison to the conventional stereological counting. The decrease in cone density in rd1 mouse was found to be equivalent to the decrease determined by stereological counting. We also studied the spatiotemporal pattern of the degeneration of cones in the rd1 mouse and show that while the reduction in cone density starts in the central part of the retina, cone degeneration progresses at the same speed over the whole retinal surface. We finally show that for mice with an inactivation of the Nucleoredoxin-like genes Nxnl1 or Nxnl2 encoding RdCVFs, the loss of cones is more pronounced in the ventral retina. The automated platform ℮-conome used here for retinal disease is a tool that can broadly accelerate translational research for neurodegenerative diseases.

  7. Catalog of Mount St. Helens 2004 - 2005 Tephra Samples with Major- and Trace-Element Geochemistry

    USGS Publications Warehouse

    Rowe, Michael C.; Thornber, Carl R.; Gooding, Daniel J.; Pallister, John S.

    2008-01-01

    This open-file report presents a catalog of information about 135 ash samples along with geochemical analyses of bulk ash, glass and individual mineral grains from tephra deposited as a result of volcanic activity at Mount St. Helens, Washington, from October 1, 2004 until August 15, 2005. This data, in conjunction with that in a companion report on 2004?2007 Mount St. Helens dome samples by Thornber and others (2008a) are presented in support of the contents of the U.S. Geological Survey Professional Paper 1750 (Sherrod and others, ed., 2008). Readers are referred to appropriate chapters in USGS Professional Paper 1750 for detailed narratives of eruptive activity during this time period and for interpretations of sample characteristics and geochemical data presented here. All ash samples reported herein are currently archived at the David A. Johnston Cascades Volcano Observatory in Vancouver, Washington. The Mount St. Helens 2004?2005 Tephra Sample Catalogue along with bulk, glass and mineral geochemistry are tabulated in 6 worksheets of the accompanying Microsoft Excel file, of2008-1131.xls. Samples in all tables are organized by collection date. Table 1 is a detailed catalog of sample information for tephra deposited downwind of Mount St. Helens between October 1, 2004 and August 18, 2005. Table 2 provides major- and trace-element analyses of 8 bulk tephra samples collected throughout that interval. Major-element compositions of 82 groundmass glass fragments, 420 feldspar grains, and 213 mafic (clinopyroxene, amphibole, hypersthene, and olivine) mineral grains from 12 ash samples collected between October 1, 2004 and March 8, 2005 are presented in tables 3 through 5. In addition, trace-element abundances of 198 feldspars from 11 ash samples (same samples as major-element analyses) are provided in table 6. Additional mineral and bulk ash analyses from 2004 and 2005 ash samples are published in chapters 30 (oxide thermometry; Pallister and others, 2008), 32 (amphibole major elements; Thornber and others, 2008b) and 37 (210Pb; 210Pb/226Pa; Reagan and others, 2008) of U.S. Geological Survey Professional Paper 1750 (Sherrod and others, 2008). A brief overview of sample collection methods is given below as an aid to deciphering the tephra sample catalog. This is followed by an explanation of the categories of sample information (column headers) in table 1. A summary of the analytical methods used to obtain the geochemical data in this report introduces the presentation of major- and trace-element geochemistry of Mount St. Helens 2004?2005 tephra samples in tables 2?6. Rhyolite glass standard analyses are reported (Appendix 1) to demonstrate the accuracy and precision of similar glass analyses presented herein.

  8. Temporally-stable active precision mount for large optics.

    PubMed

    Reinlein, Claudia; Damm, Christoph; Lange, Nicolas; Kamm, Andreas; Mohaupt, Matthias; Brady, Aoife; Goy, Matthias; Leonhard, Nina; Eberhardt, Ramona; Zeitner, Uwe; Tünnermann, Andreas

    2016-06-13

    We present a temporally-stable active mount to compensate for manufacturing-induced deformations of reflective optical components. In this paper, we introduce the design of the active mount, and its evaluation results for two sample mirrors: a quarter mirror of 115 × 105 × 9 mm3, and a full mirror of 228 × 210 × 9 mm3. The quarter mirror with 20 actuators shows a best wavefront error rms of 10 nm. Its installation position depending deformations are addressed by long-time measurements over 14 weeks indicating no significance of the orientation. Size-induced differences of the mount are studied by a full mirror with 80 manual actuators arranged in the same actuator pattern as the quarter mirror. This sample shows a wavefront error rms of (27±2) nm over a measurement period of 46 days. We conclude that the developed mount is suitable to compensate for manufacturing-induced deformations of large reflective optics, and likely to be included in the overall systems alignment procedure.

  9. Comparison between thaw-mounting and use of conductive tape for sample preparation in ToF-SIMS imaging of lipids in Drosophila microRNA-14 model.

    PubMed

    Le, Minh Uyen Thi; Son, Jin Gyeong; Shon, Hyun Kyoung; Park, Jeong Hyang; Lee, Sung Bae; Lee, Tae Geol

    2018-03-30

    Time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging elucidates molecular distributions in tissue sections, providing useful information about the metabolic pathways linked to diseases. However, delocalization of the analytes and inadequate tissue adherence during sample preparation are among some of the unfortunate phenomena associated with this technique due to their role in the reduction of the quality, reliability, and spatial resolution of the ToF-SIMS images. For these reasons, ToF-SIMS imaging requires a more rigorous sample preparation method in order to preserve the natural state of the tissues. The traditional thaw-mounting method is particularly vulnerable to altered distributions of the analytes due to thermal effects, as well as to tissue shrinkage. In the present study, the authors made comparisons of different tissue mounting methods, including the thaw-mounting method. The authors used conductive tape as the tissue-mounting material on the substrate because it does not require heat from the finger for the tissue section to adhere to the substrate and can reduce charge accumulation during data acquisition. With the conductive-tape sampling method, they were able to acquire reproducible tissue sections and high-quality images without redistribution of the molecules. Also, the authors were successful in preserving the natural states and chemical distributions of the different components of fat metabolites such as diacylglycerol and fatty acids by using the tape-supported sampling in microRNA-14 (miR-14) deleted Drosophila models. The method highlighted here shows an improvement in the accuracy of mass spectrometric imaging of tissue samples.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cornwell, Paris A; Bunn, Jeffrey R; Schmidlin, Joshua E

    The December 2010 version of the guide, ORNL/TM-2008/159, by Jeff Bunn, Josh Schmidlin, Camden Hubbard, and Paris Cornwell, has been further revised due to a major change in the GeoMagic Studio software for constructing a surface model. The Studio software update also includes a plug-in module to operate the FARO Scan Arm. Other revisions for clarity were also made. The purpose of this revision document is to guide the reader through the process of laser alignment used by NRSF2 at HFIR and VULCAN at SNS. This system was created to increase the spatial accuracy of the measurement points in amore » sample, reduce the use of neutron time used for alignment, improve experiment planning, and reduce operator error. The need for spatial resolution has been driven by the reduction in gauge volumes to the sub-millimeter level, steep strain gradients in some samples, and requests to mount multiple samples within a few days for relating data from each sample to a common sample coordinate system. The first step in this process involves mounting the sample on an indexer table in a laboratory set up for offline sample mounting and alignment in the same manner it would be mounted at either instrument. In the shared laboratory, a FARO ScanArm is used to measure the coordinates of points on the sample surface ('point cloud'), specific features and fiducial points. A Sample Coordinate System (SCS) needs to be established first. This is an advantage of the technique because the SCS can be defined in such a way to facilitate simple definition of measurement points within the sample. Next, samples are typically mounted to a frame of 80/20 and fiducial points are attached to the sample or frame then measured in the established sample coordinate system. The laser scan probe on the ScanArm can then be used to scan in an 'as-is' model of the sample as well as mounting hardware. GeoMagic Studio 12 is the software package used to construct the model from the point cloud the scan arm creates. Once a model, fiducial, and measurement files are created, a special program, called SScanSS combines the information and by simulation of the sample on the diffractometer can help plan the experiment before using neutron time. Finally, the sample is mounted on the relevant stress measurement instrument and the fiducial points are measured again. In the HFIR beam room, a laser tracker is used in conjunction with a program called CAM2 to measure the fiducial points in the NRSF2 instrument's sample positioner coordinate system. SScanSS is then used again to perform a coordinate system transformation of the measurement file locations to the sample positioner coordinate system. A procedure file is then written with the coordinates in the sample positioner coordinate system for the desired measurement locations. This file is often called a script or command file and can be further modified using excel. It is very important to note that this process is not a linear one, but rather, it often is iterative. Many of the steps in this guide are interdependent on one another. It is very important to discuss the process as it pertains to the specific sample being measured. What works with one sample may not necessarily work for another. This guide attempts to provide a typical work flow that has been successful in most cases.« less

  11. Micro/nano-mechanical test system employing tensile test holder with push-to-pull transformer

    DOEpatents

    Oh, Yunje; Cyrankowski, Edward; Shan, Zhiwei; Asif, Syed Amanula Syed

    2013-05-07

    A micromachined or microelectromechanical system (MEMS) based push-to-pull mechanical transformer for tensile testing of micro-to-nanometer scale material samples including a first structure and a second structure. The second structure is coupled to the first structure by at least one flexible element that enables the second structure to be moveable relative to the first structure, wherein the second structure is disposed relative to the first structure so as to form a pulling gap between the first and second structures such that when an external pushing force is applied to and pushes the second structure in a tensile extension direction a width of the pulling gap increases so as to apply a tensile force to a test sample mounted across the pulling gap between a first sample mounting area on the first structure and a second sample mounting area on the second structure.

  12. Micro/nano-mechanical test system employing tensile test holder with push-to-pull transformer

    DOEpatents

    Oh, Yunje; Cyrankowski, Edward; Shan, Zhiwei; Syed Asif, Syed Amanula

    2014-07-29

    A micromachined or microelectromechanical system (MEMS) based push-to-pull mechanical transformer for tensile testing of micro-to-nanometer scale material samples including a first structure and a second structure. The second structure is coupled to the first structure by at least one flexible element that enables the second structure to be moveable relative to the first structure, wherein the second structure is disposed relative to the first structure so as to form a pulling gap between the first and second structures such that when an external pushing force is applied to and pushes the second structure in a tensile extension direction a width of the pulling gap increases so as to apply a tensile force to a test sample mounted across the pulling gap between a first sample mounting area on the first structure and a second sample mounting area on the second structure.

  13. Migration monitoring with automated technology

    Treesearch

    Rhonda L. Millikin

    2005-01-01

    Automated technology can supplement ground-based methods of migration monitoring by providing: (1) unbiased and automated sampling; (2) independent validation of current methods; (3) a larger sample area for landscape-level analysis of habitat selection for stopover, and (4) an opportunity to study flight behavior. In particular, radar-acoustic sensor fusion can...

  14. AUTOMATED SOLID PHASE EXTRACTION GC/MS FOR ANALYSIS OF SEMIVOLATILES IN WATER AND SEDIMENTS

    EPA Science Inventory

    Data is presented on the development of a new automated system combining solid phase extraction (SPE) with GC/MS spectrometry for the single-run analysis of water samples containing a broad range of organic compounds. The system uses commercially available automated in-line sampl...

  15. Universal microfluidic automaton for autonomous sample processing: application to the Mars Organic Analyzer.

    PubMed

    Kim, Jungkyu; Jensen, Erik C; Stockton, Amanda M; Mathies, Richard A

    2013-08-20

    A fully integrated multilayer microfluidic chemical analyzer for automated sample processing and labeling, as well as analysis using capillary zone electrophoresis is developed and characterized. Using lifting gate microfluidic control valve technology, a microfluidic automaton consisting of a two-dimensional microvalve cellular array is fabricated with soft lithography in a format that enables facile integration with a microfluidic capillary electrophoresis device. The programmable sample processor performs precise mixing, metering, and routing operations that can be combined to achieve automation of complex and diverse assay protocols. Sample labeling protocols for amino acid, aldehyde/ketone and carboxylic acid analysis are performed automatically followed by automated transfer and analysis by the integrated microfluidic capillary electrophoresis chip. Equivalent performance to off-chip sample processing is demonstrated for each compound class; the automated analysis resulted in a limit of detection of ~16 nM for amino acids. Our microfluidic automaton provides a fully automated, portable microfluidic analysis system capable of autonomous analysis of diverse compound classes in challenging environments.

  16. Biomek 3000: the workhorse in an automated accredited forensic genetic laboratory.

    PubMed

    Stangegaard, Michael; Meijer, Per-Johan; Børsting, Claus; Hansen, Anders J; Morling, Niels

    2012-10-01

    We have implemented and validated automated protocols for a wide range of processes such as sample preparation, PCR setup, and capillary electrophoresis setup using small, simple, and inexpensive automated liquid handlers. The flexibility and ease of programming enable the Biomek 3000 to be used in many parts of the laboratory process in a modern forensic genetics laboratory with low to medium sample throughput. In conclusion, we demonstrated that sample processing for accredited forensic genetic DNA typing can be implemented on small automated liquid handlers, leading to the reduction of manual work as well as increased quality and throughput.

  17. Sensor data fusion for automated threat recognition in manned-unmanned infantry platoons

    NASA Astrophysics Data System (ADS)

    Wildt, J.; Varela, M.; Ulmke, M.; Brüggermann, B.

    2017-05-01

    To support a dismounted infantry platoon during deployment we team it with several unmanned aerial and ground vehicles (UAV and UGV, respectively). The unmanned systems integrate seamlessly into the infantry platoon, providing automated reconnaissance during movement while keeping formation as well as conducting close range reconnaissance during halt. The sensor data each unmanned system provides is continuously analyzed in real time by specialized algorithms, detecting humans in live videos of UAV mounted infrared cameras as well as gunshot detection and bearing by acoustic sensors. All recognized threats are fused into a consistent situational picture in real time, available to platoon and squad leaders as well as higher level command and control (C2) systems. This gives friendly forces local information superiority and increased situational awareness without the need to constantly monitor the unmanned systems and sensor data.

  18. Electromagnetic pulses bone healing booster

    NASA Astrophysics Data System (ADS)

    Sintea, S. R.; Pomazan, V. M.; Bica, D.; Grebenisan, D.; Bordea, N.

    2015-11-01

    Posttraumatic bone restoration triggered by the need to assist and stimulate compensatory bone growth in periodontal condition. Recent studies state that specific electromagnetic stimulation can boost the bone restoration, reaching up to 30% decrease in recovery time. Based on the existing data on the electromagnetic parameters, a digital electronic device is proposed for intra oral mounting and bone restoration stimulation in periodontal condition. The electrical signal is applied to an inductive mark that will create and impregnate magnetic field in diseased tissue. The device also monitors the status of the electromagnetic field. Controlled wave forms and pulse frequency signal at programmable intervals are obtained with optimized number of components and miniaturized using surface mounting devices (SMD) circuits and surface mounting technology (SMT), with enhanced protection against abnormal current growth, given the intra-oral environment. The system is powered by an autonomous power supply (battery), to limit the problems caused by powering medical equipment from the main power supply. Currently the device is used in clinical testing, in cycles of six up to twelve months. Basic principles for the electrical scheme and algorithms for pulse generation, pulse control, electromagnetic field control and automation of current monitoring are presented, together with the friendly user interface, suitable for medical data and patient monitoring.

  19. Springs, streams, and gas vent on and near Mount Adams volcano, Washington

    USGS Publications Warehouse

    Nathenson, Manuel; Mariner, Robert H.

    2013-01-01

    Springs and some streams on Mount Adams volcano have been sampled for chemistry and light stable isotopes of water. Spring temperatures are generally cooler than air temperatures from weather stations at the same elevation. Spring chemistry generally reflects weathering of volcanic rock from dissolved carbon dioxide. Water in some springs and streams has either dissolved hydrothermal minerals or has reacted with them to add sulfate to the water. Some samples appear to have obtained their sulfate from dissolution of gypsum while some probably involve reaction with sulfide minerals such as pyrite. Light stable isotope data for water from springs follow a local meteoric water line, and the variation of isotopes with elevation indicate that some springs have very local recharge and others have water from elevations a few hundred meters higher. No evidence was found for thermal or slightly thermal springs on Mount Adams. A sample from a seeping gas vent on Mount Adams was at ambient temperature, but the gas is similar to that found on other Cascade volcanoes. Helium isotopes are 4.4 times the value in air, indicating that there is a significant component of mantle helium. The lack of fumaroles on Mount Adams and the ambient temperature of the gas indicates that the gas is from a hydrothermal system that is no longer active.

  20. Automation and robotics considerations for a lunar base

    NASA Technical Reports Server (NTRS)

    Sliwa, Nancy E.; Harrison, F. Wallace, Jr.; Soloway, Donald I.; Mckinney, William S., Jr.; Cornils, Karin; Doggett, William R.; Cooper, Eric G.; Alberts, Thomas E.

    1992-01-01

    An envisioned lunar outpost shares with other NASA missions many of the same criteria that have prompted the development of intelligent automation techniques with NASA. Because of increased radiation hazards, crew surface activities will probably be even more restricted than current extravehicular activity in low Earth orbit. Crew availability for routine and repetitive tasks will be at least as limited as that envisioned for the space station, particularly in the early phases of lunar development. Certain tasks are better suited to the untiring watchfulness of computers, such as the monitoring and diagnosis of multiple complex systems, and the perception and analysis of slowly developing faults in such systems. In addition, mounting costs and constrained budgets require that human resource requirements for ground control be minimized. This paper provides a glimpse of certain lunar base tasks as seen through the lens of automation and robotic (A&R) considerations. This can allow a more efficient focusing of research and development not only in A&R, but also in those technologies that will depend on A&R in the lunar environment.

  1. Improvement of an automated protein crystal exchange system PAM for high-throughput data collection

    PubMed Central

    Hiraki, Masahiko; Yamada, Yusuke; Chavas, Leonard M. G.; Wakatsuki, Soichi; Matsugaki, Naohiro

    2013-01-01

    Photon Factory Automated Mounting system (PAM) protein crystal exchange systems are available at the following Photon Factory macromolecular beamlines: BL-1A, BL-5A, BL-17A, AR-NW12A and AR-NE3A. The beamline AR-NE3A has been constructed for high-throughput macromolecular crystallography and is dedicated to structure-based drug design. The PAM liquid-nitrogen Dewar can store a maximum of three SSRL cassettes. Therefore, users have to interrupt their experiments and replace the cassettes when using four or more of them during their beam time. As a result of investigation, four or more cassettes were used in AR-NE3A alone. For continuous automated data collection, the size of the liquid-nitrogen Dewar for the AR-NE3A PAM was increased, doubling the capacity. In order to check the calibration with the new Dewar and the cassette stand, calibration experiments were repeatedly performed. Compared with the current system, the parameters of the novel system are shown to be stable. PMID:24121334

  2. Future Deployment and Distribution Assessment (FDDA)

    DTIC Science & Technology

    2011-01-26

    speed capability gaps in top 10 • “Rogue” MVM gap 0 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ranked highly • All Seabasing...gaps ranked highly by USA Capability Gap Priority Number Automated Technologies Austere Access / Speed Mounted Vertical Maneuver ( MVM ) Themes and DLA...austere access, MVM , and Seabasing n ras ruc ure Predictive Logistics UNCLASSIFIED Collect and Map S&T Initiatives Developed JDDE Collected and

  3. APF-The Lick Observatory Automated Planet Finder

    DTIC Science & Technology

    2014-04-01

    resolutions up to 150,000. Overall system efficiency (fraction of photons incident on the primary mirror that are detected by the science CCD) on blaze at...A second (currently unused) Nasmyth focus can be quickly accessed via a rotatable tertiary mirror . The telescope uses a 2.41 m diameter f=1:5 primary...within 0.5″, and 90% encircled energy within 1″. The mount for the secondary mirror M2 incorporates an active tip/tilt and focus system that corrects for

  4. Automated cell disruption is a reliable and effective method of isolating RNA from fresh snap-frozen normal and malignant oral mucosa samples.

    PubMed

    Van der Vorst, Sébastien; Dekairelle, Anne-France; Irenge, Léonid; Hamoir, Marc; Robert, Annie; Gala, Jean-Luc

    2009-01-01

    This study compared automated vs. manual tissue grinding in terms of RNA yield obtained from oral mucosa biopsies. A total of 20 patients undergoing uvulectomy for sleep-related disorders and 10 patients undergoing biopsy for head and neck squamous cell carcinoma were enrolled in the study. Samples were collected, snap-frozen in liquid nitrogen, and divided into two parts of similar weight. Sample grinding was performed on one sample from each pair, either manually or using an automated cell disruptor. The performance and efficacy of each homogenization approach was compared in terms of total RNA yield (spectrophotometry, fluorometry), mRNA quantity [densitometry of specific TP53 amplicons and TP53 quantitative reverse-transcribed real-time PCR (qRT-PCR)], and mRNA quality (functional analysis of separated alleles in yeast). Although spectrophotometry and fluorometry results were comparable for both homogenization methods, TP53 expression values obtained by amplicon densitometry and qRT-PCR were significantly and consistently better after automated homogenization (p<0.005) for both uvula and tumor samples. Functional analysis of separated alleles in yeast results was better with the automated technique for tumor samples. Automated tissue homogenization appears to be a versatile, quick, and reliable method of cell disruption and is especially useful in the case of small malignant samples, which show unreliable results when processed by manual homogenization.

  5. The All Sky Automated Survey

    NASA Astrophysics Data System (ADS)

    Pojmański, G.

    2004-10-01

    The All Sky Automated Survey is a low cost project, the ultimate goal of which is detection and investigation of any kind of the photometric variability present all over the sky. The current system consists of 4 instruments covering 36x36, 9x9 (2 units) and 2x2 degrees, equipped with 2Kx2K CCDs, V,R,I standard filters and custom made automated mounts. All are working in Las Campanas Observatory, Chile in fully automated mode. In the ASAS-3 phase of the project we have been taking data at a rate of 1 measurement per 1-3 days for all available objects brighter than V=14, located south of δ=+28 deg. So far over 2 TB of images has been collected and analyzed, leading to a photometric light curve catalog of over 10 million sources. A preliminary search for variability revealed over 40,000 bright, variable sources (over 75 % were not previously known). Direct access to the data is available over the Internet: http://www.astrouw.edu.pl/˜ gp/asas. At present the ASAS Alert System is being tested. Events, like outbursts of CV's or Novae, eclipses etc. are reported within a few minutes after first detection. Due to large number of artifacts in these data raw events require verification, which can take up to 24 hours.

  6. Evaluation of an automated microplate technique in the Galileo system for ABO and Rh(D) blood grouping.

    PubMed

    Xu, Weiyi; Wan, Feng; Lou, Yufeng; Jin, Jiali; Mao, Weilin

    2014-01-01

    A number of automated devices for pretransfusion testing have recently become available. This study evaluated the Immucor Galileo System, a fully automated device based on the microplate hemagglutination technique for ABO/Rh (D) determinations. Routine ABO/Rh typing tests were performed on 13,045 samples using the Immucor automated instruments. Manual tube method was used to resolve ABO forward and reverse grouping discrepancies. D-negative test results were investigated and confirmed manually by the indirect antiglobulin test (IAT). The system rejected 70 tests for sample inadequacy. 87 samples were read as "No-type-determined" due to forward and reverse grouping discrepancies. 25 tests gave these results because of sample hemolysis. After further tests, we found 34 tests were caused by weakened RBC antibodies, 5 tests were attributable to weak A and/or B antigens, 4 tests were due to mixed-field reactions, and 8 tests had high titer cold agglutinin with blood qualifications which react only at temperatures below 34 degrees C. In the remaining 11 cases, irregular RBC antibodies were identified in 9 samples (seven anti-M and two anti-P) and two subgroups were identified in 2 samples (one A1 and one A2) by a reference laboratory. As for D typing, 2 weak D+ samples missed by automated systems gave negative results, but weak-positive reactions were observed in the IAT. The Immucor Galileo System is reliable and suited for ABO and D blood groups, some reasons may cause a discrepancy in ABO/D typing using a fully automated system. It is suggested that standardization of sample collection may improve the performance of the fully automated system.

  7. A New Automated Method and Sample Data Flow for Analysis of Volatile Nitrosamines in Human Urine*

    PubMed Central

    Hodgson, James A.; Seyler, Tiffany H.; McGahee, Ernest; Arnstein, Stephen; Wang, Lanqing

    2016-01-01

    Volatile nitrosamines (VNAs) are a group of compounds classified as probable (group 2A) and possible (group 2B) carcinogens in humans. Along with certain foods and contaminated drinking water, VNAs are detected at high levels in tobacco products and in both mainstream and sidestream smoke. Our laboratory monitors six urinary VNAs—N-nitrosodimethylamine (NDMA), N-nitrosomethylethylamine (NMEA), N-nitrosodiethylamine (NDEA), N-nitrosopiperidine (NPIP), N-nitrosopyrrolidine (NPYR), and N-nitrosomorpholine (NMOR)—using isotope dilution GC-MS/MS (QQQ) for large population studies such as the National Health and Nutrition Examination Survey (NHANES). In this paper, we report for the first time a new automated sample preparation method to more efficiently quantitate these VNAs. Automation is done using Hamilton STAR™ and Caliper Staccato™ workstations. This new automated method reduces sample preparation time from 4 hours to 2.5 hours while maintaining precision (inter-run CV < 10%) and accuracy (85% - 111%). More importantly this method increases sample throughput while maintaining a low limit of detection (<10 pg/mL) for all analytes. A streamlined sample data flow was created in parallel to the automated method, in which samples can be tracked from receiving to final LIMs output with minimal human intervention, further minimizing human error in the sample preparation process. This new automated method and the sample data flow are currently applied in bio-monitoring of VNAs in the US non-institutionalized population NHANES 2013-2014 cycle. PMID:26949569

  8. 21 CFR 864.5200 - Automated cell counter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated cell counter. 864.5200 Section 864.5200....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the...

  9. 21 CFR 864.5240 - Automated blood cell diluting apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated blood cell diluting apparatus. 864.5240... § 864.5240 Automated blood cell diluting apparatus. (a) Identification. An automated blood cell diluting apparatus is a fully automated or semi-automated device used to make appropriate dilutions of a blood sample...

  10. 21 CFR 864.5240 - Automated blood cell diluting apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated blood cell diluting apparatus. 864.5240... § 864.5240 Automated blood cell diluting apparatus. (a) Identification. An automated blood cell diluting apparatus is a fully automated or semi-automated device used to make appropriate dilutions of a blood sample...

  11. [Establishment of Automation System for Detection of Alcohol in Blood].

    PubMed

    Tian, L L; Shen, Lei; Xue, J F; Liu, M M; Liang, L J

    2017-02-01

    To establish an automation system for detection of alcohol content in blood. The determination was performed by automated workstation of extraction-headspace gas chromatography (HS-GC). The blood collection with negative pressure, sealing time of headspace bottle and sample needle were checked and optimized in the abstraction of automation system. The automatic sampling was compared with the manual sampling. The quantitative data obtained by the automated workstation of extraction-HS-GC for alcohol was stable. The relative differences of two parallel samples were less than 5%. The automated extraction was superior to the manual extraction. A good linear relationship was obtained at the alcohol concentration range of 0.1-3.0 mg/mL ( r ≥0.999) with good repeatability. The method is simple and quick, with more standard experiment process and accurate experimental data. It eliminates the error from the experimenter and has good repeatability, which can be applied to the qualitative and quantitative detections of alcohol in blood. Copyright© by the Editorial Department of Journal of Forensic Medicine

  12. A Highly Flexible, Automated System Providing Reliable Sample Preparation in Element- and Structure-Specific Measurements.

    PubMed

    Vorberg, Ellen; Fleischer, Heidi; Junginger, Steffen; Liu, Hui; Stoll, Norbert; Thurow, Kerstin

    2016-10-01

    Life science areas require specific sample pretreatment to increase the concentration of the analytes and/or to convert the analytes into an appropriate form for the detection and separation systems. Various workstations are commercially available, allowing for automated biological sample pretreatment. Nevertheless, due to the required temperature, pressure, and volume conditions in typical element and structure-specific measurements, automated platforms are not suitable for analytical processes. Thus, the purpose of the presented investigation was the design, realization, and evaluation of an automated system ensuring high-precision sample preparation for a variety of analytical measurements. The developed system has to enable system adaption and high performance flexibility. Furthermore, the system has to be capable of dealing with the wide range of required vessels simultaneously, allowing for less cost and time-consuming process steps. However, the system's functionality has been confirmed in various validation sequences. Using element-specific measurements, the automated system was up to 25% more precise compared to the manual procedure and as precise as the manual procedure using structure-specific measurements. © 2015 Society for Laboratory Automation and Screening.

  13. The spectrum and aetiology of mycotic infections from a tertiary care hospital from Western part of India.

    PubMed

    Gandham, Nageswari Rajesh; Jadhav, Savita Vivek; Sardar, Moumita; Vyawahare, Chanda; Misra, Rabind Ranath

    2013-10-01

    In the past few years, there has been an increase in infections caused by fungal aetiology. This is mainly due to increase in sizes of populations which are at risk. Also, fungi which were previously considered as non-pathogenic have been increasingly implicated. Hence, this study was taken up. To assess the magnitude of mycotic infections in this set up. To assess the spectrum of fungi which are involved in various infections. Total 704 samples taken over two and half period were included. They consisted of various samples like sputum, blood, urine, sterile body fluids, corneal scrapings. These were processed by conventional mycological techniques. These included direct microscopy after Gram staining and KOH mount, culture on Sabouraud's dextrose agar (SDA), corn meal agar, brain heart infusion (BHI), brain heart infusion agar (BHIA) and others, as required. For non-albicans Candida, the automated Vitek 2 C system was used. Various moulds and yeasts were identified up to genus level and species level. Of 704 samples, 336 (48%) were positive for fungal culture. Of these, 244 isolates were yeast like fungi, 81 were moulds, 7 were yeasts and 4 were dimorphic. Among blood stream infections, non-albicans Candida were the commonest isolates. In the urine samples, C. albicans was the commonest isolate. From corneal scrapings, only moulds and dimorphic fungi were isolated. Incidence of non- albicans Candidal infections is increasing. Culture and identification of mycotic infections is essential for commencement of suitable antifungal therapy.

  14. Automated Microflow NMR: Routine Analysis of Five-Microliter Samples

    PubMed Central

    Jansma, Ariane; Chuan, Tiffany; Geierstanger, Bernhard H.; Albrecht, Robert W.; Olson, Dean L.; Peck, Timothy L.

    2006-01-01

    A microflow CapNMR probe double-tuned for 1H and 13C was installed on a 400-MHz NMR spectrometer and interfaced to an automated liquid handler. Individual samples dissolved in DMSO-d6 are submitted for NMR analysis in vials containing as little as 10 μL of sample. Sets of samples are submitted in a low-volume 384-well plate. Of the 10 μL of sample per well, as with vials, 5 μL is injected into the microflow NMR probe for analysis. For quality control of chemical libraries, 1D NMR spectra are acquired under full automation from 384-well plates on as many as 130 compounds within 24 h using 128 scans per spectrum and a sample-to-sample cycle time of ∼11 min. Because of the low volume requirements and high mass sensitivity of the microflow NMR system, 30 nmol of a typical small molecule is sufficient to obtain high-quality, well-resolved, 1D proton or 2D COSY NMR spectra in ∼6 or 20 min of data acquisition time per experiment, respectively. Implementation of pulse programs with automated solvent peak identification and suppression allow for reliable data collection, even for samples submitted in fully protonated DMSO. The automated microflow NMR system is controlled and monitored using web-based software. PMID:16194121

  15. Development of a Double Glass Mounting Method Using Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) and its Evaluation for Permanent Mounting of Small Nematodes.

    PubMed

    Zahabiun, Farzaneh; Sadjjadi, Seyed Mahmoud; Esfandiari, Farideh

    2015-01-01

    Permanent slide preparation of nematodes especially small ones is time consuming, difficult and they become scarious margins. Regarding this problem, a modified double glass mounting method was developed and compared with classic method. A total of 209 nematode samples from human and animal origin were fixed and stained with Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) followed by double glass mounting and classic dehydration method using Canada balsam as their mounting media. The slides were evaluated in different dates and times, more than four years. Different photos were made with different magnification during the evaluation time. The double glass mounting method was stable during this time and comparable with classic method. There were no changes in morphologic structures of nematodes using double glass mounting method with well-defined and clear differentiation between different organs of nematodes in this method. Using this method is cost effective and fast for mounting of small nematodes comparing to classic method.

  16. Development of a Double Glass Mounting Method Using Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) and its Evaluation for Permanent Mounting of Small Nematodes

    PubMed Central

    ZAHABIUN, Farzaneh; SADJJADI, Seyed Mahmoud; ESFANDIARI, Farideh

    2015-01-01

    Background: Permanent slide preparation of nematodes especially small ones is time consuming, difficult and they become scarious margins. Regarding this problem, a modified double glass mounting method was developed and compared with classic method. Methods: A total of 209 nematode samples from human and animal origin were fixed and stained with Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) followed by double glass mounting and classic dehydration method using Canada balsam as their mounting media. The slides were evaluated in different dates and times, more than four years. Different photos were made with different magnification during the evaluation time. Results: The double glass mounting method was stable during this time and comparable with classic method. There were no changes in morphologic structures of nematodes using double glass mounting method with well-defined and clear differentiation between different organs of nematodes in this method. Conclusion: Using this method is cost effective and fast for mounting of small nematodes comparing to classic method. PMID:26811729

  17. Establishing a novel automated magnetic bead-based method for the extraction of DNA from a variety of forensic samples.

    PubMed

    Witt, Sebastian; Neumann, Jan; Zierdt, Holger; Gébel, Gabriella; Röscheisen, Christiane

    2012-09-01

    Automated systems have been increasingly utilized for DNA extraction by many forensic laboratories to handle growing numbers of forensic casework samples while minimizing the risk of human errors and assuring high reproducibility. The step towards automation however is not easy: The automated extraction method has to be very versatile to reliably prepare high yields of pure genomic DNA from a broad variety of sample types on different carrier materials. To prevent possible cross-contamination of samples or the loss of DNA, the components of the kit have to be designed in a way that allows for the automated handling of the samples with no manual intervention necessary. DNA extraction using paramagnetic particles coated with a DNA-binding surface is predestined for an automated approach. For this study, we tested different DNA extraction kits using DNA-binding paramagnetic particles with regard to DNA yield and handling by a Freedom EVO(®)150 extraction robot (Tecan) equipped with a Te-MagS magnetic separator. Among others, the extraction kits tested were the ChargeSwitch(®)Forensic DNA Purification Kit (Invitrogen), the PrepFiler™Automated Forensic DNA Extraction Kit (Applied Biosystems) and NucleoMag™96 Trace (Macherey-Nagel). After an extensive test phase, we established a novel magnetic bead extraction method based upon the NucleoMag™ extraction kit (Macherey-Nagel). The new method is readily automatable and produces high yields of DNA from different sample types (blood, saliva, sperm, contact stains) on various substrates (filter paper, swabs, cigarette butts) with no evidence of a loss of magnetic beads or sample cross-contamination. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  18. High quality tissue miniarray technique using a conventional TV/radio telescopic antenna.

    PubMed

    Elkablawy, Mohamed A; Albasri, Abdulkader M

    2015-01-01

    The tissue microarray (TMA) is widely accepted as a fast and cost-effective research tool for in situ tissue analysis in modern pathology. However, the current automated and manual TMA techniques have some drawbacks restricting their productivity. Our study aimed to introduce an improved manual tissue miniarray (TmA) technique that is simple and readily applicable to a broad range of tissue samples. In this study, a conventional TV/radio telescopic antenna was used to punch tissue cores manually from donor paraffin embedded tissue blocks which were pre-incubated at 40oC. The cores were manually transferred, organized and attached to a standard block mould, and filled with liquid paraffin to construct TmA blocks without any use of recipient paraffin blocks. By using a conventional TV/radio antenna, it was possible to construct TmA paraffin blocks with variable formats of array size and number (2-mm x 42, 2.5-mm x 30, 3-mm x 24, 4-mm x 20 and 5-mm x 12 cores). Up to 2-mm x 84 cores could be mounted and stained on a standard microscopic slide by cutting two sections from two different blocks and mounting them beside each other. The technique was simple and caused minimal damage to the donor blocks. H and E and immunostained slides showed well-defined tissue morphology and array configuration. This technique is easy to reproduce, quick, inexpensive and creates uniform blocks with abundant tissues without specialized equipment. It was found to improve the stability of the cores within the paraffin block and facilitated no losses during cutting and immunostaining.

  19. 21 CFR 864.5200 - Automated cell counter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the patient's peripheral blood (blood circulating in one of the body's extremities, such as the arm). These...

  20. 21 CFR 864.5200 - Automated cell counter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the patient's peripheral blood (blood circulating in one of the body's extremities, such as the arm). These...

  1. 21 CFR 864.5200 - Automated cell counter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the patient's peripheral blood (blood circulating in one of the body's extremities, such as the arm). These...

  2. 21 CFR 864.5200 - Automated cell counter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the patient's peripheral blood (blood circulating in one of the body's extremities, such as the arm). These...

  3. Nonanalytic Laboratory Automation: A Quarter Century of Progress.

    PubMed

    Hawker, Charles D

    2017-06-01

    Clinical laboratory automation has blossomed since the 1989 AACC meeting, at which Dr. Masahide Sasaki first showed a western audience what his laboratory had implemented. Many diagnostics and other vendors are now offering a variety of automated options for laboratories of all sizes. Replacing manual processing and handling procedures with automation was embraced by the laboratory community because of the obvious benefits of labor savings and improvement in turnaround time and quality. Automation was also embraced by the diagnostics vendors who saw automation as a means of incorporating the analyzers purchased by their customers into larger systems in which the benefits of automation were integrated to the analyzers.This report reviews the options that are available to laboratory customers. These options include so called task-targeted automation-modules that range from single function devices that automate single tasks (e.g., decapping or aliquoting) to multifunction workstations that incorporate several of the functions of a laboratory sample processing department. The options also include total laboratory automation systems that use conveyors to link sample processing functions to analyzers and often include postanalytical features such as refrigerated storage and sample retrieval.Most importantly, this report reviews a recommended process for evaluating the need for new automation and for identifying the specific requirements of a laboratory and developing solutions that can meet those requirements. The report also discusses some of the practical considerations facing a laboratory in a new implementation and reviews the concept of machine vision to replace human inspections. © 2017 American Association for Clinical Chemistry.

  4. Economic and workflow analysis of a blood bank automated system.

    PubMed

    Shin, Kyung-Hwa; Kim, Hyung Hoi; Chang, Chulhun L; Lee, Eun Yup

    2013-07-01

    This study compared the estimated costs and times required for ABO/Rh(D) typing and unexpected antibody screening using an automated system and manual methods. The total cost included direct and labor costs. Labor costs were calculated on the basis of the average operator salaries and unit values (minutes), which was the hands-on time required to test one sample. To estimate unit values, workflows were recorded on video, and the time required for each process was analyzed separately. The unit values of ABO/Rh(D) typing using the manual method were 5.65 and 8.1 min during regular and unsocial working hours, respectively. The unit value was less than 3.5 min when several samples were tested simultaneously. The unit value for unexpected antibody screening was 2.6 min. The unit values using the automated method for ABO/Rh(D) typing, unexpected antibody screening, and both simultaneously were all 1.5 min. The total cost of ABO/Rh(D) typing of only one sample using the automated analyzer was lower than that of testing only one sample using the manual technique but higher than that of testing several samples simultaneously. The total cost of unexpected antibody screening using an automated analyzer was less than that using the manual method. ABO/Rh(D) typing using an automated analyzer incurs a lower unit value and cost than that using the manual technique when only one sample is tested at a time. Unexpected antibody screening using an automated analyzer always incurs a lower unit value and cost than that using the manual technique.

  5. Individualized FAC on bottom tab subassemblies to minimize adhesive gap between emitter and optics

    NASA Astrophysics Data System (ADS)

    Sauer, Sebastian; Müller, Tobias; Haag, Sebastian; Beleke, Andreas; Zontar, Daniel; Baum, Christoph; Brecher, Christian

    2017-02-01

    High Power Diode Laser (HPDL) systems with short focal length fast-axis collimators (FAC) require submicron assembly precision. Conventional FAC-Lens assembly processes require adhesive gaps of 50 microns or more in order to compensate for component tolerances (e.g. deviation of back focal length) and previous assembly steps. In order to control volumetric shrinkage of fast-curing UV-adhesives shrinkage compensation is mandatory. The novel approach described in this paper aims to minimize the impact of volumetric shrinkage due to the adhesive gap between HPDL edge emitters and FAC-Lens. Firstly, the FAC is actively aligned to the edge emitter without adhesives or bottom tab. The relative position and orientation of FAC to emitter are measured and stored. Consecutively, an individual subassembly of FAC and bottom tab is assembled on Fraunhofer IPT's mounting station with a precision of +/-1 micron. Translational and lateral offsets can be compensated, so that a narrow and uniform glue gap for the consecutive bonding process of bottom tab to heatsink applies (Figure 4). Accordingly, FAC and bottom tab are mounted to the heatsink without major shrinkage compensation. Fraunhofer IPT's department assembly of optical systems and automation has made several publications regarding active alignment of FAC lenses [SPIE LASE 8241-12], volumetric shrinkage compensation [SPIE LASE 9730-28] and FAC on bottom tab assembly [SPIE LASE 9727-31] in automated production environments. The approach described in this paper combines these and is the logical continuation of that work towards higher quality of HPDLs.

  6. Semi-automated 96-well liquid-liquid extraction for quantitation of drugs in biological fluids.

    PubMed

    Zhang, N; Hoffman, K L; Li, W; Rossi, D T

    2000-02-01

    A semi-automated liquid-liquid extraction (LLE) technique for biological fluid sample preparation was introduced for the quantitation of four drugs in rat plasma. All liquid transferring during the sample preparation was automated using a Tomtec Quadra 96 Model 320 liquid handling robot, which processed up to 96 samples in parallel. The samples were either in 96-deep-well plate or tube-rack format. One plate of samples can be prepared in approximately 1.5 h, and the 96-well plate is directly compatible with the autosampler of an LC/MS system. Selection of organic solvents and recoveries are discussed. Also, precision, relative error, linearity and quantitation of the semi automated LLE method are estimated for four example drugs using LC/MS/MS with a multiple reaction monitoring (MRM) approach. The applicability of this method and future directions are evaluated.

  7. Automated quantitative cytological analysis using portable microfluidic microscopy.

    PubMed

    Jagannadh, Veerendra Kalyan; Murthy, Rashmi Sreeramachandra; Srinivasan, Rajesh; Gorthi, Sai Siva

    2016-06-01

    In this article, a portable microfluidic microscopy based approach for automated cytological investigations is presented. Inexpensive optical and electronic components have been used to construct a simple microfluidic microscopy system. In contrast to the conventional slide-based methods, the presented method employs microfluidics to enable automated sample handling and image acquisition. The approach involves the use of simple in-suspension staining and automated image acquisition to enable quantitative cytological analysis of samples. The applicability of the presented approach to research in cellular biology is shown by performing an automated cell viability assessment on a given population of yeast cells. Further, the relevance of the presented approach to clinical diagnosis and prognosis has been demonstrated by performing detection and differential assessment of malaria infection in a given sample. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Bacterial and fungal DNA extraction from blood samples: automated protocols.

    PubMed

    Lorenz, Michael G; Disqué, Claudia; Mühl, Helge

    2015-01-01

    Automation in DNA isolation is a necessity for routine practice employing molecular diagnosis of infectious agents. To this end, the development of automated systems for the molecular diagnosis of microorganisms directly in blood samples is at its beginning. Important characteristics of systems demanded for routine use include high recovery of microbial DNA, DNA-free containment for the reduction of DNA contamination from exogenous sources, DNA-free reagents and consumables, ideally a walkaway system, and economical pricing of the equipment and consumables. Such full automation of DNA extraction evaluated and in use for sepsis diagnostics is yet not available. Here, we present protocols for the semiautomated isolation of microbial DNA from blood culture and low- and high-volume blood samples. The protocols include a manual pretreatment step followed by automated extraction and purification of microbial DNA.

  9. Inferring Meal Eating Activities in Real World Settings from Ambient Sounds: A Feasibility Study

    PubMed Central

    Thomaz, Edison; Zhang, Cheng; Essa, Irfan; Abowd, Gregory D.

    2015-01-01

    Dietary self-monitoring has been shown to be an effective method for weight-loss, but it remains an onerous task despite recent advances in food journaling systems. Semi-automated food journaling can reduce the effort of logging, but often requires that eating activities be detected automatically. In this work we describe results from a feasibility study conducted in-the-wild where eating activities were inferred from ambient sounds captured with a wrist-mounted device; twenty participants wore the device during one day for an average of 5 hours while performing normal everyday activities. Our system was able to identify meal eating with an F-score of 79.8% in a person-dependent evaluation, and with 86.6% accuracy in a person-independent evaluation. Our approach is intended to be practical, leveraging off-the-shelf devices with audio sensing capabilities in contrast to systems for automated dietary assessment based on specialized sensors. PMID:25859566

  10. SAMI Automated Plug Plate Configuration

    NASA Astrophysics Data System (ADS)

    Lorente, N. P. F.; Farrell, T.; Goodwin, M.

    2013-10-01

    The Sydney-AAO Multi-object Integral field spectrograph (SAMI) is a prototype wide-field system at the Anglo-Australian Telescope (AAT) which uses a plug-plate to mount its 13×61-core imaging fibre bundles (hexabundles) in the optical path at the telescope's prime focus. In this paper we describe the process of determining the positions of the plug-plate holes, where plates contain three or more stacked observation configurations. The process, which up until now has involved several separate processes and has required significant manual configuration and checking, is now being automated to increase efficiency and reduce error. This is carried out by means of a thin Java controller layer which drives the configuration cycle. This layer controls the user interface and the C++ algorithm layer where the plate configuration and optimisation is carried out. Additionally, through the Aladin display package, it provides visualisation and facilitates user verification of the resulting plates.

  11. Real-time control of the robotic lunar observatory telescope

    USGS Publications Warehouse

    Anderson, J.M.; Becker, K.J.; Kieffer, H.H.; Dodd, D.N.

    1999-01-01

    The US Geological Survey operates an automated observatory dedicated to the radiometry of the Moon with the objective of developing a multispectral, spatially resolved photometric model of the Moon to be used in the calibration of Earth-orbiting spacecraft. Interference filters are used with two imaging instruments to observe the Moon in 32 passbands from 350-2500 nm. Three computers control the telescope mount and instruments with a fourth computer acting as a master system to control all observation activities. Real-time control software has been written to operate the instrumentation and to automate the observing process. The observing software algorithms use information including the positions of objects in the sky, the phase of the Moon, and the times of evening and morning twilight to decide how to observe program objects. The observatory has been operating in a routine mode since late 1995 and is expected to continue through at least 2002 without significant modifications.

  12. Apparatus for microbiological sampling. [including automatic swabbing

    NASA Technical Reports Server (NTRS)

    Wilkins, J. R.; Mills, S. M. (Inventor)

    1974-01-01

    An automatic apparatus is described for microbiologically sampling surface using a cotton swab which eliminates human error. The apparatus includes a self-powered transport device, such as a motor-driven wheeled cart, which mounts a swabbing motor drive for a crank arm which supports a swab in the free end thereof. The swabbing motor is pivotably mounted and an actuator rod movable responsive to the cart traveling a predetermined distance provides lifting of the swab from the surface being sampled and reversal of the direction of travel of the cart.

  13. Specimen coordinate automated measuring machine/fiducial automated measuring machine

    DOEpatents

    Hedglen, Robert E.; Jacket, Howard S.; Schwartz, Allan I.

    1991-01-01

    The Specimen coordinate Automated Measuring Machine (SCAMM) and the Fiducial Automated Measuring Machine (FAMM) is a computer controlled metrology system capable of measuring length, width, and thickness, and of locating fiducial marks. SCAMM and FAMM have many similarities in their designs, and they can be converted from one to the other without taking them out of the hot cell. Both have means for: supporting a plurality of samples and a standard; controlling the movement of the samples in the +/- X and Y directions; determining the coordinates of the sample; compensating for temperature effects; and verifying the accuracy of the measurements and repeating as necessary. SCAMM and FAMM are designed to be used in hot cells.

  14. A method of mounting multiple otoliths for beam-based microchemical analyses

    USGS Publications Warehouse

    Donohoe, C.J.; Zimmerman, C.E.

    2010-01-01

    Beam-based analytical methods are widely used to measure the concentrations of elements and isotopes in otoliths. These methods usually require that otoliths be individually mounted and prepared to properly expose the desired growth region to the analytical beam. Most analytical instruments, such as LA-ICPMS and ion and electron microprobes, have sample holders that will accept only one to six slides or mounts at a time. We describe a method of mounting otoliths that allows for easy transfer of many otoliths to a single mount after they have been prepared. Such an approach increases the number of otoliths that can be analyzed in a single session by reducing the need open the sample chamber to exchange slides-a particularly time consuming step on instruments that operate under vacuum. For ion and electron microprobes, the method also greatly reduces the number of slides that must be coated with an electrical conductor prior to analysis. In this method, a narrow strip of cover glass is first glued at one end to a standard microscope slide. The otolith is then mounted in thermoplastic resin on the opposite, free end of the strip. The otolith can then be ground and flipped, if needed, by reheating the mounting medium. After otolith preparation is complete, the cover glass is cut with a scribe to free the otolith and up to 20 small otoliths can be arranged on a single petrographic slide. ?? 2010 The Author(s).

  15. Growth And Characterization Studies Of Advanced Infrared Heterostructures

    DTIC Science & Technology

    2015-06-30

    controlled within 50 arc-seconds for all the samples. The three samples were then processed into deep-etched mesa -type photodiodes, by using standard...contact ultraviolet lithography and wet-chemical etching. The circular mesa -size ranged from 25 to 400 µm in diameter. A 200-nm-thick SiNx film...coating was applied on top of the mesa . Devices were mounted on ceramic leadless chip carriers, and then mounted in the cryostat to characterize their

  16. NE-CAT Upgrade of the Bending Magnet Beamline 8BM at the ALS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Jun; Ogata, Craig; Yang Xiaochun

    2007-01-19

    NE-CAT, North East Collaborative Access Team, bending magnet beamline (8BM) is a beamline for protein crystallography. Recently, the beamline has undergone upgrades of its x-ray optics, control system, and the addition of a robot automounter. The first crystal of the double crystal monochromator was replaced by a new design offered by Oxford Danfysik with a micro-finned, direct water-cooled crystal assembly that would provide better cooling and reduced thermal distortion, pressure induced bulge, and residual strain. Gear reduced motors were added to enhance the torque of the bender and obtain better control. For measuring displacement of the bender directly, two linearmore » variable differential transformers (LVDT) were installed to the second crystal assembly. Early optics characterization and analysis has been carried out. Besides the upgrade of the optical components, the Blu-Ice control system originally developed at SSRL has been implemented. The installation of an automated robotic sample mounting system, from the ALS, was carried out in collaboration with the engineering group at LBNL. Preliminary results are presented.« less

  17. Instrumental neutron activation analysis data for cloud-water particulate samples, Mount Bamboo, Taiwan

    USGS Publications Warehouse

    Lin, Neng-Huei; Sheu, Guey-Rong; Wetherbee, Gregory A.; Debey, Timothy M.

    2013-01-01

    Cloud water was sampled on Mount Bamboo in northern Taiwan during March 22-24, 2002. Cloud-water samples were filtered using 0.45-micron filters to remove particulate material from the water samples. Filtered particulates were analyzed by instrumental neutron activation analysis (INAA) at the U.S. Geological Survey National Reactor Facility in Denver, Colorado, in February 2012. INAA elemental composition data for the particulate materials are presented. These data complement analyses of the aqueous portion of the cloud-water samples, which were performed earlier by the Department of Atmospheric Sciences, National Central University, Taiwan. The data are intended for evaluation of atmospheric transport processes and air-pollution sources in Southeast Asia.

  18. Flow through electrode with automated calibration

    DOEpatents

    Szecsody, James E [Richland, WA; Williams, Mark D [Richland, WA; Vermeul, Vince R [Richland, WA

    2002-08-20

    The present invention is an improved automated flow through electrode liquid monitoring system. The automated system has a sample inlet to a sample pump, a sample outlet from the sample pump to at least one flow through electrode with a waste port. At least one computer controls the sample pump and records data from the at least one flow through electrode for a liquid sample. The improvement relies upon (a) at least one source of a calibration sample connected to (b) an injection valve connected to said sample outlet and connected to said source, said injection valve further connected to said at least one flow through electrode, wherein said injection valve is controlled by said computer to select between said liquid sample or said calibration sample. Advantages include improved accuracy because of more frequent calibrations, no additional labor for calibration, no need to remove the flow through electrode(s), and minimal interruption of sampling.

  19. Automated hybridization/imaging device for fluorescent multiplex DNA sequencing

    DOEpatents

    Weiss, R.B.; Kimball, A.W.; Gesteland, R.F.; Ferguson, F.M.; Dunn, D.M.; Di Sera, L.J.; Cherry, J.L.

    1995-11-28

    A method is disclosed for automated multiplex sequencing of DNA with an integrated automated imaging hybridization chamber system. This system comprises an hybridization chamber device for mounting a membrane containing size-fractionated multiplex sequencing reaction products, apparatus for fluid delivery to the chamber device, imaging apparatus for light delivery to the membrane and image recording of fluorescence emanating from the membrane while in the chamber device, and programmable controller apparatus for controlling operation of the system. The multiplex reaction products are hybridized with a probe, the enzyme (such as alkaline phosphatase) is bound to a binding moiety on the probe, and a fluorogenic substrate (such as a benzothiazole derivative) is introduced into the chamber device by the fluid delivery apparatus. The enzyme converts the fluorogenic substrate into a fluorescent product which, when illuminated in the chamber device with a beam of light from the imaging apparatus, excites fluorescence of the fluorescent product to produce a pattern of hybridization. The pattern of hybridization is imaged by a CCD camera component of the imaging apparatus to obtain a series of digital signals. These signals are converted by the controller apparatus into a string of nucleotides corresponding to the nucleotide sequence an automated sequence reader. The method and apparatus are also applicable to other membrane-based applications such as colony and plaque hybridization and Southern, Northern, and Western blots. 9 figs.

  20. Automated hybridization/imaging device for fluorescent multiplex DNA sequencing

    DOEpatents

    Weiss, Robert B.; Kimball, Alvin W.; Gesteland, Raymond F.; Ferguson, F. Mark; Dunn, Diane M.; Di Sera, Leonard J.; Cherry, Joshua L.

    1995-01-01

    A method is disclosed for automated multiplex sequencing of DNA with an integrated automated imaging hybridization chamber system. This system comprises an hybridization chamber device for mounting a membrane containing size-fractionated multiplex sequencing reaction products, apparatus for fluid delivery to the chamber device, imaging apparatus for light delivery to the membrane and image recording of fluorescence emanating from the membrane while in the chamber device, and programmable controller apparatus for controlling operation of the system. The multiplex reaction products are hybridized with a probe, then an enzyme (such as alkaline phosphatase) is bound to a binding moiety on the probe, and a fluorogenic substrate (such as a benzothiazole derivative) is introduced into the chamber device by the fluid delivery apparatus. The enzyme converts the fluorogenic substrate into a fluorescent product which, when illuminated in the chamber device with a beam of light from the imaging apparatus, excites fluorescence of the fluorescent product to produce a pattern of hybridization. The pattern of hybridization is imaged by a CCD camera component of the imaging apparatus to obtain a series of digital signals. These signals are converted by the controller apparatus into a string of nucleotides corresponding to the nucleotide sequence an automated sequence reader. The method and apparatus are also applicable to other membrane-based applications such as colony and plaque hybridization and Southern, Northern, and Western blots.

  1. DEdicated MONitor of EXotransits and Transients (DEMONEXT): Low-Cost Robotic and Automated Telescope for Followup of Exoplanetary Transits and Transients

    NASA Astrophysics Data System (ADS)

    Villanueva, Steven; Eastman, Jason D.; Gaudi, B. Scott; Pogge, Richard W.; Stassun, Keivan G.; Trueblood, Mark; Trueblood, Patricia

    2017-01-01

    We present the design, development, and early science from the DEdicated MONitor of EXotransits and Transients (DEMONEXT), an automated and robotic 20 inch telescope jointly funded by The Ohio State University and Vanderbilt University. The telescope is a PlaneWave CDK20 f/6.8 Corrected Dall-Kirkham Astrograph telescope on a Mathis Instruments MI-750/1000 Fork Mount located at Winer Observatory in Sonoita, AZ. DEMONEXT has a Hedrick electronic focuser, Finger Lakes Instrumentation (FLI) CFW-3-10 filter wheel, and a 2048 x 2048 pixel FLI Proline CCD3041 camera with a pixel scale of 0.90 arc-seconds per pixel and a 30.7 x 30.7 arc-minute field-of-view. The telescope's automation, controls, and scheduling are implemented in Python, including a facility to add new targets in real time for rapid follow-up of time-critical targets. DEMONEXT will be used for the confirmation and detailed investigation of newly discovered planet candidates from the Kilodegree Extremely Little Telescope (KELT) survey, exploration of the atmospheres of Hot Jupiters via transmission spectroscopy and thermal emission measurements, and monitoring of select eclipsing binary star systems as benchmarks for models of stellar evolution. DEMONEXT will enable rapid confirmation imaging of supernovae, flare stars, tidal disruption events, and other transients discovered by the All Sky Automated Survey for SuperNovae (ASAS-SN).

  2. AUTOMATED ANALYSIS OF AQUEOUS SAMPLES CONTAINING PESTICIDES, ACIDIC/BASIC/NEUTRAL SEMIVOLATILES AND VOLATILE ORGANIC COMPOUNDS BY SOLID PHASE EXTRACTION COUPLED IN-LINE TO LARGE VOLUME INJECTION GC/MS

    EPA Science Inventory

    Data is presented on the development of a new automated system combining solid phase extraction (SPE) with GC/MS spectrometry for the single-run analysis of water samples containing a broad range of organic compounds. The system uses commercially available automated in-line 10-m...

  3. Comparison study of membrane filtration direct count and an automated coliform and Escherichia coli detection system for on-site water quality testing.

    PubMed

    Habash, Marc; Johns, Robert

    2009-10-01

    This study compared an automated Escherichia coli and coliform detection system with the membrane filtration direct count technique for water testing. The automated instrument performed equal to or better than the membrane filtration test in analyzing E. coli-spiked samples and blind samples with interference from Proteus vulgaris or Aeromonas hydrophila.

  4. Secure Mobility Draft Concept Description

    DTIC Science & Technology

    2006-10-01

    S T A T E S A R M Y R E S E A R C H L A B O R A T O R Y Approved for public release: distribution is unlimited RUX06 Experiment • Capstone CAT ...experiment • Evaluate effectiveness of CAT program in improving the performance and/or reducing the workload for a mounted Soldier through the use of...Automation Testbed ( CAT ) • Robotic Follower (RF) • Fire Control Node Engagement Technologies (FC-NET) • Robotics Collaboration (RC) 311/17/05 U N IT E

  5. An Automated System for the Control of, and Data Acquisition from Multiphoton Ionization and Fluorescence Lifetime Measurements.

    DTIC Science & Technology

    1986-09-01

    Quanta- Ray company , which also supplied the laser used for the multiphoton work. The, burner was mounted on a translator stage from Velmex, Inc...and no longer exists as a process in the system. When the user analysis program has completed, the lifetime program is again automatically re-started...KCHAR) RETURN 100 FORMAT(I3) 101 FORMAT(F7.2) END SUBROUTINE LAB4 FODA SE"oteD C This routine puts the label "INTEGRAL FROM DATA SET" on the MDP C screen

  6. Automated gantry-type stitching system

    NASA Technical Reports Server (NTRS)

    Thrash, Patrick J. (Inventor); Miller, Jeffrey L. (Inventor); Pallas, Kenneth G. (Inventor); Trank, Robert C. (Inventor); Fox, Rhoda (Inventor); Korte, Mike (Inventor); Codos, Richard (Inventor); Korolev, Aleksandr (Inventor); Collan, William (Inventor)

    1999-01-01

    A stitching system includes a gantry that is movable along a material support table. Mounted to the gantry are a plurality of stitching heads and bobbins. The stitching heads are individually controllable in a z-direction, and the bobbins are individually controllable in the z-direction. Each stitching head is paired with a bobbin. Each pair of stitching heads and the bobbins is controlled synchronously in the z-direction. The stitching system is well-suited for stitching preforms of aircraft wing covers and other preforms having variable thickness and compound, contoured three-dimensional surfaces.

  7. Testing of visual field with virtual reality goggles in manual and visual grasp modes.

    PubMed

    Wroblewski, Dariusz; Francis, Brian A; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas

    2014-01-01

    Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4-6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.

  8. The Upgrade Programme for the Structural Biology beamlines at the European Synchrotron Radiation Facility - High throughput sample evaluation and automation

    NASA Astrophysics Data System (ADS)

    Theveneau, P.; Baker, R.; Barrett, R.; Beteva, A.; Bowler, M. W.; Carpentier, P.; Caserotto, H.; de Sanctis, D.; Dobias, F.; Flot, D.; Guijarro, M.; Giraud, T.; Lentini, M.; Leonard, G. A.; Mattenet, M.; McCarthy, A. A.; McSweeney, S. M.; Morawe, C.; Nanao, M.; Nurizzo, D.; Ohlsson, S.; Pernot, P.; Popov, A. N.; Round, A.; Royant, A.; Schmid, W.; Snigirev, A.; Surr, J.; Mueller-Dieckmann, C.

    2013-03-01

    Automation and advances in technology are the key elements in addressing the steadily increasing complexity of Macromolecular Crystallography (MX) experiments. Much of this complexity is due to the inter-and intra-crystal heterogeneity in diffraction quality often observed for crystals of multi-component macromolecular assemblies or membrane proteins. Such heterogeneity makes high-throughput sample evaluation an important and necessary tool for increasing the chances of a successful structure determination. The introduction at the ESRF of automatic sample changers in 2005 dramatically increased the number of samples that were tested for diffraction quality. This "first generation" of automation, coupled with advances in software aimed at optimising data collection strategies in MX, resulted in a three-fold increase in the number of crystal structures elucidated per year using data collected at the ESRF. In addition, sample evaluation can be further complemented using small angle scattering experiments on the newly constructed bioSAXS facility on BM29 and the micro-spectroscopy facility (ID29S). The construction of a second generation of automated facilities on the MASSIF (Massively Automated Sample Screening Integrated Facility) beam lines will build on these advances and should provide a paradigm shift in how MX experiments are carried out which will benefit the entire Structural Biology community.

  9. A comparison of gas geochemistry of fumaroles in the 1912 ash-flow sheet and on active stratovolcanoes, Katmai National Park, Alaska

    USGS Publications Warehouse

    Sheppard, D.S.; Janik, C.J.; Keith, T.E.C.

    1992-01-01

    Fumarolic gas samples collected in 1978 and 1979 from the stratovolcanoes Mount Griggs, Mount Mageik, and the 1953-68 SW Trident cone in Katmai National Park, Alaska, have been analysed and the results presented here. Comparison with recalculated analyses of samples collected from the Valley of Ten Thousand Smokes (VTTS) in 1917 and 1919 demonstrates differences between gases from the short-lived VTTS fumaroles, which were not directly magma related, and the fumaroles on the volcanic peaks. Fumarolic gases of Mount Griggs have an elevated total He content, suggesting a more direct deep crustal or mantle source for these gases than those from the other volcanoes. ?? 1992.

  10. Automated biowaste sampling system improved feces collection, mass measurement and sampling. [by use of a breadboard model

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Young, R.

    1974-01-01

    The capability of the basic automated Biowaste Sampling System (ABSS) hardware was extended and improved through the design, fabrication and test of breadboard hardware. A preliminary system design effort established the feasibility of integrating the breadboard concepts into the ABSS.

  11. Turbidity-controlled sampling for suspended sediment load estimation

    Treesearch

    Jack Lewis

    2003-01-01

    Abstract - Automated data collection is essential to effectively measure suspended sediment loads in storm events, particularly in small basins. Continuous turbidity measurements can be used, along with discharge, in an automated system that makes real-time sampling decisions to facilitate sediment load estimation. The Turbidity Threshold Sampling method distributes...

  12. [DNA Extraction from Old Bones by AutoMate Express™ System].

    PubMed

    Li, B; Lü, Z

    2017-08-01

    To establish a method for extracting DNA from old bones by AutoMate Express™ system. Bones were grinded into powder by freeze-mill. After extraction by AutoMate Express™, DNA were amplified and genotyped by Identifiler®Plus and MinFiler™ kits. DNA were extracted from 10 old bone samples, which kept in different environments with the postmortem interval from 10 to 20 years, in 3 hours by AutoMate Express™ system. Complete STR typing results were obtained from 8 samples. AutoMate Express™ system can quickly and efficiently extract DNA from old bones, which can be applied in forensic practice. Copyright© by the Editorial Department of Journal of Forensic Medicine

  13. Invention and validation of an automated camera system that uses optical character recognition to identify patient name mislabeled samples.

    PubMed

    Hawker, Charles D; McCarthy, William; Cleveland, David; Messinger, Bonnie L

    2014-03-01

    Mislabeled samples are a serious problem in most clinical laboratories. Published error rates range from 0.39/1000 to as high as 1.12%. Standardization of bar codes and label formats has not yet achieved the needed improvement. The mislabel rate in our laboratory, although low compared with published rates, prompted us to seek a solution to achieve zero errors. To reduce or eliminate our mislabeled samples, we invented an automated device using 4 cameras to photograph the outside of a sample tube. The system uses optical character recognition (OCR) to look for discrepancies between the patient name in our laboratory information system (LIS) vs the patient name on the customer label. All discrepancies detected by the system's software then require human inspection. The system was installed on our automated track and validated with production samples. We obtained 1 009 830 images during the validation period, and every image was reviewed. OCR passed approximately 75% of the samples, and no mislabeled samples were passed. The 25% failed by the system included 121 samples actually mislabeled by patient name and 148 samples with spelling discrepancies between the patient name on the customer label and the patient name in our LIS. Only 71 of the 121 mislabeled samples detected by OCR were found through our normal quality assurance process. We have invented an automated camera system that uses OCR technology to identify potential mislabeled samples. We have validated this system using samples transported on our automated track. Full implementation of this technology offers the possibility of zero mislabeled samples in the preanalytic stage.

  14. High Throughput Petrochronology and Sedimentary Provenance Analysis by Automated Phase Mapping and LAICPMS

    NASA Astrophysics Data System (ADS)

    Vermeesch, Pieter; Rittner, Martin; Petrou, Ethan; Omma, Jenny; Mattinson, Chris; Garzanti, Eduardo

    2017-11-01

    The first step in most geochronological studies is to extract dateable minerals from the host rock, which is time consuming, removes textural context, and increases the chance for sample cross contamination. We here present a new method to rapidly perform in situ analyses by coupling a fast scanning electron microscope (SEM) with Energy Dispersive X-ray Spectrometer (EDS) to a Laser Ablation Inductively Coupled Plasma Mass Spectrometer (LAICPMS) instrument. Given a polished hand specimen, a petrographic thin section, or a grain mount, Automated Phase Mapping (APM) by SEM/EDS produces chemical and mineralogical maps from which the X-Y coordinates of the datable minerals are extracted. These coordinates are subsequently passed on to the laser ablation system for isotopic analysis. We apply the APM + LAICPMS method to three igneous, metamorphic, and sedimentary case studies. In the first case study, a polished slab of granite from Guernsey was scanned for zircon, producing a 609 ± 8 Ma weighted mean age. The second case study investigates a paragneiss from an ultra high pressure terrane in the north Qaidam terrane (Qinghai, China). One hundred seven small (25 µm) metamorphic zircons were analyzed by LAICPMS to confirm a 419 ± 4 Ma age of peak metamorphism. The third and final case study uses APM + LAICPMS to generate a large provenance data set and trace the provenance of 25 modern sediments from Angola, documenting longshore drift of Orange River sediments over a distance of 1,500 km. These examples demonstrate that APM + LAICPMS is an efficient and cost effective way to improve the quantity and quality of geochronological data.

  15. A UHF RFID positioning system for use in warehouse navigation by employees with cognitive disability.

    PubMed

    Gunther, Eric J M; Sliker, Levin J; Bodine, Cathy

    2017-11-01

    Unemployment among the almost 5 million working-age adults with cognitive disabilities in the USA is a costly problem in both tax dollars and quality of life. Job coaching is an effective tool to overcome this, but the cost of job coaching services sums with every new employee or change of employment roles. There is a need for a cost-effective, automated alternative to job coaching that incurs a one-time cost and can be reused for multiple employees or roles. An effective automated job coach must be aware of its location and the location of destinations within the job site. This project presents a design and prototype of a cart-mounted indoor positioning and navigation system with necessary original software using Ultra High Frequency Radio Frequency Identification (UHF RFID). The system presented in this project for use within a warehouse setting is one component of an automated job coach to assist in the job of order filler. The system demonstrated accuracy to within 0.3 m under the correct conditions with strong potential to serve as the basis for an effective indoor navigation system to assist warehouse workers with disabilities. Implications for rehabilitation An automated job coach could improve employability of and job retention for people with cognitive disabilities. An indoor navigation system using ultra high frequency radio frequency identification was proposed with an average positioning accuracy of 0.3 m. The proposed system, in combination with a non-linear context-aware prompting system, could be used as an automated job coach for warehouse order fillers with cognitive disabilities.

  16. Fully Automated Sample Preparation for Ultrafast N-Glycosylation Analysis of Antibody Therapeutics.

    PubMed

    Szigeti, Marton; Lew, Clarence; Roby, Keith; Guttman, Andras

    2016-04-01

    There is a growing demand in the biopharmaceutical industry for high-throughput, large-scale N-glycosylation profiling of therapeutic antibodies in all phases of product development, but especially during clone selection when hundreds of samples should be analyzed in a short period of time to assure their glycosylation-based biological activity. Our group has recently developed a magnetic bead-based protocol for N-glycosylation analysis of glycoproteins to alleviate the hard-to-automate centrifugation and vacuum-centrifugation steps of the currently used protocols. Glycan release, fluorophore labeling, and cleanup were all optimized, resulting in a <4 h magnetic bead-based process with excellent yield and good repeatability. This article demonstrates the next level of this work by automating all steps of the optimized magnetic bead-based protocol from endoglycosidase digestion, through fluorophore labeling and cleanup with high-throughput sample processing in 96-well plate format, using an automated laboratory workstation. Capillary electrophoresis analysis of the fluorophore-labeled glycans was also optimized for rapid (<3 min) separation to accommodate the high-throughput processing of the automated sample preparation workflow. Ultrafast N-glycosylation analyses of several commercially relevant antibody therapeutics are also shown and compared to their biosimilar counterparts, addressing the biological significance of the differences. © 2015 Society for Laboratory Automation and Screening.

  17. Parallel Adaptive High-Order CFD Simulations Characterizing Cavity Acoustics for the Complete SOFIA Aircraft

    NASA Technical Reports Server (NTRS)

    Barad, Michael F.; Brehm, Christoph; Kiris, Cetin C.; Biswas, Rupak

    2014-01-01

    This paper presents one-of-a-kind MPI-parallel computational fluid dynamics simulations for the Stratospheric Observatory for Infrared Astronomy (SOFIA). SOFIA is an airborne, 2.5-meter infrared telescope mounted in an open cavity in the aft of a Boeing 747SP. These simulations focus on how the unsteady flow field inside and over the cavity interferes with the optical path and mounting of the telescope. A temporally fourth-order Runge-Kutta, and spatially fifth-order WENO-5Z scheme was used to perform implicit large eddy simulations. An immersed boundary method provides automated gridding for complex geometries and natural coupling to a block-structured Cartesian adaptive mesh refinement framework. Strong scaling studies using NASA's Pleiades supercomputer with up to 32,000 cores and 4 billion cells shows excellent scaling. Dynamic load balancing based on execution time on individual AMR blocks addresses irregularities caused by the highly complex geometry. Limits to scaling beyond 32K cores are identified, and targeted code optimizations are discussed.

  18. How robust are in situ observations for validating satellite-derived albedo over the dark zone of the Greenland Ice Sheet?

    NASA Astrophysics Data System (ADS)

    Ryan, J. C.; Hubbard, A.; Irvine-Fynn, T. D.; Doyle, S. H.; Cook, J. M.; Stibal, M.; Box, J. E.

    2017-06-01

    Calibration and validation of satellite-derived ice sheet albedo data require high-quality, in situ measurements commonly acquired by up and down facing pyranometers mounted on automated weather stations (AWS). However, direct comparison between ground and satellite-derived albedo can only be justified when the measured surface is homogeneous at the length-scale of both satellite pixel and in situ footprint. Here we use digital imagery acquired by an unmanned aerial vehicle to evaluate point-to-pixel albedo comparisons across the western, ablating margin of the Greenland Ice Sheet. Our results reveal that in situ measurements overestimate albedo by up to 0.10 at the end of the melt season because the ground footprints of AWS-mounted pyranometers are insufficient to capture the spatial heterogeneity of the ice surface as it progressively ablates and darkens. Statistical analysis of 21 AWS across the entire Greenland Ice Sheet reveals that almost half suffer from this bias, including some AWS located within the wet snow zone.

  19. How robust are in situ observations for validating satellite-derived albedo over the dark zone of the Greenland Ice Sheet?

    NASA Astrophysics Data System (ADS)

    Ryan, J.; Hubbard, A., II; Irvine-Fynn, T. D.; Doyle, S. H.; Cook, J.; Stibal, M.; Smith, L. C.; Box, J. E.

    2017-12-01

    Calibration and validation of satellite-derived ice sheet albedo data require high-quality, in situ measurements commonly acquired by up and down facing pyranometers mounted on automated weather stations (AWS). However, direct comparison between ground and satellite-derived albedo can only be justified when the measured surface is homogeneous at the length-scale of both satellite pixel and in situ footprint. We used digital imagery acquired by an unmanned aerial vehicle to evaluate point-to-pixel albedo comparisons across the western, ablating margin of the Greenland Ice Sheet. Our results reveal that in situ measurements overestimate albedo by up to 0.10 at the end of the melt season because the ground footprints of AWS-mounted pyranometers are insufficient to capture the spatial heterogeneity of the ice surface as it progressively ablates and darkens. Statistical analysis of 21 AWS across the entire Greenland Ice Sheet reveals that almost half suffer from this bias, including some AWS located within the wet snow zone.

  20. Correction

    NASA Astrophysics Data System (ADS)

    1996-04-01

    Fallout of volcanic ash to the deep South China Sea induced by the 1991 eruption of Mount Pinatubo (Philippines): Correction Geology, v. 23, p. 885 888 (October 1995) On p. 885, the last sentence of the Introduction should be: Here we report the first in situ record of a submarine fallout of volcanic ash following one of the largest magnitude subaerial eruptions of this century, the June 15, 1991, paroxysmal explosion of Mount Pinatubo (lat 15.148, long 120.358) in the Philippines. The first sentence under the head SUBMARINE FALLOUT MONITORING AND COMPOSITION should be: Fallout of Pinatubo tephra was recorded by fully automated collection devices (sediment traps) moored in 1190 and 3730 m water depth at 14.608N, 115.108E (Fig. 1). On p. 886, center column, the second sentence under the head LINKS TO SUBAERIAL ASH-PLUME MOVEMENT should be: Ash was ejected to a maximum altitude of 35 40 km, and at about14:20 the cloud spread out laterally into a giant umbrella region between 25 and 30 km altitude.

  1. Evaluation of mouse red blood cell and platelet counting with an automated hematology analyzer.

    PubMed

    Fukuda, Teruko; Asou, Eri; Nogi, Kimiko; Goto, Kazuo

    2017-10-07

    An evaluation of mouse red blood cell (RBC) and platelet (PLT) counting with an automated hematology analyzer was performed with three strains of mice, C57BL/6 (B6), BALB/c (BALB) and DBA/2 (D2). There were no significant differences in RBC and PLT counts between manual and automated optical methods in any of the samples, except for D2 mice. For D2, RBC counts obtained using the manual method were significantly lower than those obtained using the automated optical method (P<0.05), and PLT counts obtained using the manual method were higher than those obtained using the automated optical method (P<0.05). An automated hematology analyzer can be used for RBC and PLT counting; however, an appropriate method should be selected when D2 mice samples are used.

  2. Timing of degassing and plagioclase growth in lavas erupted from Mount St. Helens, 2004-2005, from 210Po-210Pb-226Ra disequilibria: Chapter 37 in A volcano rekindled: the renewed eruption of Mount St. Helens, 2004-2006

    USGS Publications Warehouse

    Reagan, Mark K.; Cooper, Kari M.; Pallister, John S.; Thornber, Carl R.; Wortel, Matthew; Sherrod, David R.; Scott, William E.; Stauffer, Peter H.

    2008-01-01

    Disequilibrium between 210Po, 210Pb, and 226Ra was measured on rocks and plagioclase mineral separates erupted during the first year of the ongoing eruption of Mount St. Helens. The purpose of this study was to monitor the volatile fluxing and crystal growth that occurred in the weeks, years, and decades leading up to eruption. Whole-rock samples were leached in dilute HCl to remove 210Po precipitated in open spaces. Before leaching, samples had variable initial (210Po) values, whereas after leaching, the groundmasses of nearly all juvenile samples were found to have had (210Po) ≈ 0 when they erupted. Thus, most samples degassed 210Po both before and after the magmas switched from open- to closed-system degassing. All juvenile samples have (210Pb)/(226Ra) ratios within 2 δ of equilibrium, suggesting that the magmas involved in the ongoing eruption did not have strong, persistent fluxes of 222Rn in or out of magmas during the decades and years leading to eruption. These equilibrium values also require a period of at least a century after magma generation and the last significant differentiation of the Mount St. Helens dacites. Despite this, the elevated (210Pb)/(226Ra) value measured in a plagioclase mineral separate from lava erupted in 2004 suggests that a significant proportion of this plagioclase grew within a few decades of eruption. The combined dataset suggests that for most 2004-5 lavas, the last stage of open-system degassing of the dacite magmas at Mount St. Helens is confined to the period between 1-2 years and 1-2 weeks before eruption, whereas plagioclase large enough to be included in the mineral separate grew around the time of the 1980s eruption or earlier.

  3. Sequential injection-bead injection-lab-on-valve coupled to high-performance liquid chromatography for online renewable micro-solid-phase extraction of carbamate residues in food and environmental samples.

    PubMed

    Vichapong, Jitlada; Burakham, Rodjana; Srijaranai, Supalax; Grudpan, Kate

    2011-07-01

    A sequential injection-bead injection-lab-on-valve system was hyphenated to HPLC for online renewable micro-solid-phase extraction of carbamate insecticides. The carbamates studied were isoprocarb, methomyl, carbaryl, carbofuran, methiocarb, promecarb, and propoxur. LiChroprep(®) RP-18 beads (25-40 μm) were employed as renewable sorbent packing in a microcolumn situated inside the LOV platform mounted above the multiposition valve of the sequential injection system. The analytes sorbed by the microcolumn were eluted using 80% acetonitrile in 0.1% acetic acid before online introduction to the HPLC system. Separation was performed on an Atlantis C-18 column (4.6 × 150 mm, 5 μm) utilizing gradient elution with a flow rate of 1.0 mL/min and a detection wavelength at 270 nm. The sequential injection system offers the means of performing automated handling of sample preconcentration and matrix removal. The enrichment factors ranged between 20 and 125, leading to limits of detection (LODs) in the range of 1-20 μg/L. Good reproducibility was obtained with relative standard deviations of <0.7 and 5.4% for retention time and peak area, respectively. The developed method has been successfully applied to the determination of carbamate residues in fruit, vegetable, and water samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Life Sciences Research Facility automation requirements and concepts for the Space Station

    NASA Technical Reports Server (NTRS)

    Rasmussen, Daryl N.

    1986-01-01

    An evaluation is made of the methods and preliminary results of a study on prospects for the automation of the NASA Space Station's Life Sciences Research Facility. In order to remain within current Space Station resource allocations, approximately 85 percent of planned life science experiment tasks must be automated; these tasks encompass specimen care and feeding, cage and instrument cleaning, data acquisition and control, sample analysis, waste management, instrument calibration, materials inventory and management, and janitorial work. Task automation will free crews for specimen manipulation, tissue sampling, data interpretation and communication with ground controllers, and experiment management.

  5. The Final Proceedings for Mullite and Mullite Ceramics Held in Irsee, Germany on 7-9 September 1994

    DTIC Science & Technology

    1996-01-01

    10 Rue Vauquelin, Department of Mechanical Engineering, Fairey Tecramics Ltd, F-75231 Paris C~dex, France Worcester Polytechnic Institute, Mount ...through an evacu- ated beam path. The sample solution was mounted in a glass capillary 3 mm in diameter so* C and 8 p/m in thickness. Intensity measurements...thickness round the Cr atoms. The second peak is assumed product of about 2 in the region just after the - edge were mounted on Scotch Tape. The spectra

  6. Sample Preparation of Corn Seed Tissue to Prevent Analyte Relocations for Mass Spectrometry Imaging

    NASA Astrophysics Data System (ADS)

    Kim, Shin Hye; Kim, Jeongkwon; Lee, Young Jin; Lee, Tae Geol; Yoon, Sohee

    2017-08-01

    Corn seed tissue sections were prepared by the tape support method using an adhesive tape, and mass spectrometry imaging (MSI) was performed. The effect of heat generated during sample preparation was investigated by time-of-flight secondary mass spectrometry (TOF-SIMS) imaging of corn seed tissue prepared by the tape support and the thaw-mounted methods. Unlike thaw-mounted sample preparation, the tape support method does not cause imaging distortion because of the absence of heat, which can cause migration of the analytes on the sample. By applying the tape-support method, the corn seed tissue was prepared without structural damage and MSI with accurate spatial information of analytes was successfully performed.

  7. Automation in clinical bacteriology: what system to choose?

    PubMed

    Greub, G; Prod'hom, G

    2011-05-01

    With increased activity and reduced financial and human resources, there is a need for automation in clinical bacteriology. Initial processing of clinical samples includes repetitive and fastidious steps. These tasks are suitable for automation, and several instruments are now available on the market, including the WASP (Copan), Previ-Isola (BioMerieux), Innova (Becton-Dickinson) and Inoqula (KIESTRA) systems. These new instruments allow efficient and accurate inoculation of samples, including four main steps: (i) selecting the appropriate Petri dish; (ii) inoculating the sample; (iii) spreading the inoculum on agar plates to obtain, upon incubation, well-separated bacterial colonies; and (iv) accurate labelling and sorting of each inoculated media. The challenge for clinical bacteriologists is to determine what is the ideal automated system for their own laboratory. Indeed, different solutions will be preferred, according to the number and variety of samples, and to the types of sample that will be processed with the automated system. The final choice is troublesome, because audits proposed by industrials risk being biased towards the solution proposed by their company, and because these automated systems may not be easily tested on site prior to the final decision, owing to the complexity of computer connections between the laboratory information system and the instrument. This article thus summarizes the main parameters that need to be taken into account for choosing the optimal system, and provides some clues to help clinical bacteriologists to make their choice. © 2011 The Authors. Clinical Microbiology and Infection © 2011 European Society of Clinical Microbiology and Infectious Diseases.

  8. The RABiT: a rapid automated biodosimetry tool for radiological triage. II. Technological developments.

    PubMed

    Garty, Guy; Chen, Youhua; Turner, Helen C; Zhang, Jian; Lyulko, Oleksandra V; Bertucci, Antonella; Xu, Yanping; Wang, Hongliang; Simaan, Nabil; Randers-Pehrson, Gerhard; Lawrence Yao, Y; Brenner, David J

    2011-08-01

    Over the past five years the Center for Minimally Invasive Radiation Biodosimetry at Columbia University has developed the Rapid Automated Biodosimetry Tool (RABiT), a completely automated, ultra-high throughput biodosimetry workstation. This paper describes recent upgrades and reliability testing of the RABiT. The RABiT analyses fingerstick-derived blood samples to estimate past radiation exposure or to identify individuals exposed above or below a cut-off dose. Through automated robotics, lymphocytes are extracted from fingerstick blood samples into filter-bottomed multi-well plates. Depending on the time since exposure, the RABiT scores either micronuclei or phosphorylation of the histone H2AX, in an automated robotic system, using filter-bottomed multi-well plates. Following lymphocyte culturing, fixation and staining, the filter bottoms are removed from the multi-well plates and sealed prior to automated high-speed imaging. Image analysis is performed online using dedicated image processing hardware. Both the sealed filters and the images are archived. We have developed a new robotic system for lymphocyte processing, making use of an upgraded laser power and parallel processing of four capillaries at once. This system has allowed acceleration of lymphocyte isolation, the main bottleneck of the RABiT operation, from 12 to 2 sec/sample. Reliability tests have been performed on all robotic subsystems. Parallel handling of multiple samples through the use of dedicated, purpose-built, robotics and high speed imaging allows analysis of up to 30,000 samples per day.

  9. The RABiT: A Rapid Automated Biodosimetry Tool For Radiological Triage. II. Technological Developments

    PubMed Central

    Garty, Guy; Chen, Youhua; Turner, Helen; Zhang, Jian; Lyulko, Oleksandra; Bertucci, Antonella; Xu, Yanping; Wang, Hongliang; Simaan, Nabil; Randers-Pehrson, Gerhard; Yao, Y. Lawrence; Brenner, David J.

    2011-01-01

    Purpose Over the past five years the Center for Minimally Invasive Radiation Biodosimetry at Columbia University has developed the Rapid Automated Biodosimetry Tool (RABiT), a completely automated, ultra-high throughput biodosimetry workstation. This paper describes recent upgrades and reliability testing of the RABiT. Materials and methods The RABiT analyzes fingerstick-derived blood samples to estimate past radiation exposure or to identify individuals exposed above or below a cutoff dose. Through automated robotics, lymphocytes are extracted from fingerstick blood samples into filter-bottomed multi-well plates. Depending on the time since exposure, the RABiT scores either micronuclei or phosphorylation of the histone H2AX, in an automated robotic system, using filter-bottomed multi-well plates. Following lymphocyte culturing, fixation and staining, the filter bottoms are removed from the multi-well plates and sealed prior to automated high-speed imaging. Image analysis is performed online using dedicated image processing hardware. Both the sealed filters and the images are archived. Results We have developed a new robotic system for lymphocyte processing, making use of an upgraded laser power and parallel processing of four capillaries at once. This system has allowed acceleration of lymphocyte isolation, the main bottleneck of the RABiT operation, from 12 to 2 sec/sample. Reliability tests have been performed on all robotic subsystems. Conclusions Parallel handling of multiple samples through the use of dedicated, purpose-built, robotics and high speed imaging allows analysis of up to 30,000 samples per day. PMID:21557703

  10. Gas pressure assisted microliquid-liquid extraction coupled online to direct infusion mass spectrometry: a new automated screening platform for bioanalysis.

    PubMed

    Raterink, Robert-Jan; Witkam, Yoeri; Vreeken, Rob J; Ramautar, Rawi; Hankemeier, Thomas

    2014-10-21

    In the field of bioanalysis, there is an increasing demand for miniaturized, automated, robust sample pretreatment procedures that can be easily connected to direct-infusion mass spectrometry (DI-MS) in order to allow the high-throughput screening of drugs and/or their metabolites in complex body fluids like plasma. Liquid-Liquid extraction (LLE) is a common sample pretreatment technique often used for complex aqueous samples in bioanalysis. Despite significant developments that have been made in automated and miniaturized LLE procedures, fully automated LLE techniques allowing high-throughput bioanalytical studies on small-volume samples using direct infusion mass spectrometry, have not been matured yet. Here, we introduce a new fully automated micro-LLE technique based on gas-pressure assisted mixing followed by passive phase separation, coupled online to nanoelectrospray-DI-MS. Our method was characterized by varying the gas flow and its duration through the solvent mixture. For evaluation of the analytical performance, four drugs were spiked to human plasma, resulting in highly acceptable precision (RSD down to 9%) and linearity (R(2) ranging from 0.990 to 0.998). We demonstrate that our new method does not only allow the reliable extraction of analytes from small sample volumes of a few microliters in an automated and high-throughput manner, but also performs comparable or better than conventional offline LLE, in which the handling of small volumes remains challenging. Finally, we demonstrate the applicability of our method for drug screening on dried blood spots showing excellent linearity (R(2) of 0.998) and precision (RSD of 9%). In conclusion, we present the proof of principe of a new high-throughput screening platform for bioanalysis based on a new automated microLLE method, coupled online to a commercially available nano-ESI-DI-MS.

  11. Developing and utilizing an Euler computational method for predicting the airframe/propulsion effects for an aft-mounted turboprop transport. Volume 2: User guide

    NASA Technical Reports Server (NTRS)

    Chen, H. C.; Neback, H. E.; Kao, T. J.; Yu, N. Y.; Kusunose, K.

    1991-01-01

    This manual explains how to use an Euler based computational method for predicting the airframe/propulsion integration effects for an aft-mounted turboprop transport. The propeller power effects are simulated by the actuator disk concept. This method consists of global flow field analysis and the embedded flow solution for predicting the detailed flow characteristics in the local vicinity of an aft-mounted propfan engine. The computational procedure includes the use of several computer programs performing four main functions: grid generation, Euler solution, grid embedding, and streamline tracing. This user's guide provides information for these programs, including input data preparations with sample input decks, output descriptions, and sample Unix scripts for program execution in the UNICOS environment.

  12. A setup for measuring the Seebeck coefficient and the electrical resistivity of bulk thermoelectric materials

    NASA Astrophysics Data System (ADS)

    Fu, Qiang; Xiong, Yucheng; Zhang, Wenhua; Xu, Dongyan

    2017-09-01

    This paper presents a setup for measuring the Seebeck coefficient and the electrical resistivity of bulk thermoelectric materials. The sample holder was designed to have a compact structure and can be directly mounted in a standard cryostat system for temperature-dependent measurements. For the Seebeck coefficient measurement, a thin bar-shaped sample is mounted bridging two copper bases; and two ceramic heaters are used to generate a temperature gradient along the sample. Two type T thermocouples are used to determine both temperature and voltage differences between two widely separated points on the sample. The thermocouple junction is flattened into a disk and pressed onto the sample surface by using a spring load. The flexible fixation method we adopted not only simplifies the sample mounting process but also prevents thermal contact deterioration due to the mismatch of thermal expansion coefficients between the sample and other parts. With certain modifications, the sample holder can also be used for four-probe electrical resistivity measurements. High temperature measurements are essential for thermoelectric power generation. The experimental system we developed is capable of measuring the Seebeck coefficient and the electrical resistivity of bulk thermoelectric materials in a wide temperature range from 80 to 500 K, which can be further extended to even higher temperatures. Measurements on two standard materials, constantan and nickel, confirmed the accuracy and the reliability of the system.

  13. Automated indirect immunofluorescence evaluation of antinuclear autoantibodies on HEp-2 cells.

    PubMed

    Voigt, Jörn; Krause, Christopher; Rohwäder, Edda; Saschenbrecker, Sandra; Hahn, Melanie; Danckwardt, Maick; Feirer, Christian; Ens, Konstantin; Fechner, Kai; Barth, Erhardt; Martinetz, Thomas; Stöcker, Winfried

    2012-01-01

    Indirect immunofluorescence (IIF) on human epithelial (HEp-2) cells is considered as the gold standard screening method for the detection of antinuclear autoantibodies (ANA). However, in terms of automation and standardization, it has not been able to keep pace with most other analytical techniques used in diagnostic laboratories. Although there are already some automation solutions for IIF incubation in the market, the automation of result evaluation is still in its infancy. Therefore, the EUROPattern Suite has been developed as a comprehensive automated processing and interpretation system for standardized and efficient ANA detection by HEp-2 cell-based IIF. In this study, the automated pattern recognition was compared to conventional visual interpretation in a total of 351 sera. In the discrimination of positive from negative samples, concordant results between visual and automated evaluation were obtained for 349 sera (99.4%, kappa = 0.984). The system missed out none of the 272 antibody-positive samples and identified 77 out of 79 visually negative samples (analytical sensitivity/specificity: 100%/97.5%). Moreover, 94.0% of all main antibody patterns were recognized correctly by the software. Owing to its performance characteristics, EUROPattern enables fast, objective, and economic IIF ANA analysis and has the potential to reduce intra- and interlaboratory variability.

  14. Automated Indirect Immunofluorescence Evaluation of Antinuclear Autoantibodies on HEp-2 Cells

    PubMed Central

    Voigt, Jörn; Krause, Christopher; Rohwäder, Edda; Saschenbrecker, Sandra; Hahn, Melanie; Danckwardt, Maick; Feirer, Christian; Ens, Konstantin; Fechner, Kai; Barth, Erhardt; Martinetz, Thomas; Stöcker, Winfried

    2012-01-01

    Indirect immunofluorescence (IIF) on human epithelial (HEp-2) cells is considered as the gold standard screening method for the detection of antinuclear autoantibodies (ANA). However, in terms of automation and standardization, it has not been able to keep pace with most other analytical techniques used in diagnostic laboratories. Although there are already some automation solutions for IIF incubation in the market, the automation of result evaluation is still in its infancy. Therefore, the EUROPattern Suite has been developed as a comprehensive automated processing and interpretation system for standardized and efficient ANA detection by HEp-2 cell-based IIF. In this study, the automated pattern recognition was compared to conventional visual interpretation in a total of 351 sera. In the discrimination of positive from negative samples, concordant results between visual and automated evaluation were obtained for 349 sera (99.4%, kappa = 0.984). The system missed out none of the 272 antibody-positive samples and identified 77 out of 79 visually negative samples (analytical sensitivity/specificity: 100%/97.5%). Moreover, 94.0% of all main antibody patterns were recognized correctly by the software. Owing to its performance characteristics, EUROPattern enables fast, objective, and economic IIF ANA analysis and has the potential to reduce intra- and interlaboratory variability. PMID:23251220

  15. Feasibility of automated speech sample collection with stuttering children using interactive voice response (IVR) technology.

    PubMed

    Vogel, Adam P; Block, Susan; Kefalianos, Elaina; Onslow, Mark; Eadie, Patricia; Barth, Ben; Conway, Laura; Mundt, James C; Reilly, Sheena

    2015-04-01

    To investigate the feasibility of adopting automated interactive voice response (IVR) technology for remotely capturing standardized speech samples from stuttering children. Participants were 10 6-year-old stuttering children. Their parents called a toll-free number from their homes and were prompted to elicit speech from their children using a standard protocol involving conversation, picture description and games. The automated IVR system was implemented using an off-the-shelf telephony software program and delivered by a standard desktop computer. The software infrastructure utilizes voice over internet protocol. Speech samples were automatically recorded during the calls. Video recordings were simultaneously acquired in the home at the time of the call to evaluate the fidelity of the telephone collected samples. Key outcome measures included syllables spoken, percentage of syllables stuttered and an overall rating of stuttering severity using a 10-point scale. Data revealed a high level of relative reliability in terms of intra-class correlation between the video and telephone acquired samples on all outcome measures during the conversation task. Findings were less consistent for speech samples during picture description and games. Results suggest that IVR technology can be used successfully to automate remote capture of child speech samples.

  16. Campylobacter in Broiler Chicken and Broiler Meat in Sri Lanka: Influence of Semi-Automated vs. Wet Market Processing on Campylobacter Contamination of Broiler Neck Skin Samples.

    PubMed

    Kottawatta, Kottawattage S A; Van Bergen, Marcel A P; Abeynayake, Preeni; Wagenaar, Jaap A; Veldman, Kees T; Kalupahana, Ruwani S

    2017-11-29

    Broiler meat can become contaminated with Campylobacter of intestinal origin during processing. The present study aimed to identify the prevalence of Campylobacter in broiler flocks and meat contamination at retail shops, and determine the influence of semi-automated and wet market processing on Campylobacter contamination of neck skin samples. Samples were collected from semi-automated plants ( n = 102) and wet markets ( n = 25). From each batch of broilers, pooled caecal samples and neck skin samples were tested for Campylobacter . Broiler meat purchased from retail outlets ( n = 37) was also tested. The prevalence of Campylobacter colonized broiler flocks was 67%. The contamination of meat at retail was 59%. Both semi-automated and wet market processing resulted to contaminate the broiler neck skins to the levels of 27.4% and 48%, respectively. When Campylobacter -free broiler flocks were processed in semi-automated facilities 15% (5/33) of neck skin samples became contaminated by the end of processing whereas 25% (2/8) became contaminated after wet market processing. Characterization of isolates revealed a higher proportion of C. coli compared to C. jejuni . Higher proportions of isolates were resistant to important antimicrobials. This study shows the importance of Campylobacter in poultry industry in Sri Lanka and the need for controlling antimicrobial resistance.

  17. Campylobacter in Broiler Chicken and Broiler Meat in Sri Lanka: Influence of Semi-Automated vs. Wet Market Processing on Campylobacter Contamination of Broiler Neck Skin Samples

    PubMed Central

    Kottawatta, Kottawattage S. A.; Van Bergen, Marcel A. P.; Abeynayake, Preeni; Wagenaar, Jaap A.; Veldman, Kees T.; Kalupahana, Ruwani S.

    2017-01-01

    Broiler meat can become contaminated with Campylobacter of intestinal origin during processing. The present study aimed to identify the prevalence of Campylobacter in broiler flocks and meat contamination at retail shops, and determine the influence of semi-automated and wet market processing on Campylobacter contamination of neck skin samples. Samples were collected from semi-automated plants (n = 102) and wet markets (n = 25). From each batch of broilers, pooled caecal samples and neck skin samples were tested for Campylobacter. Broiler meat purchased from retail outlets (n = 37) was also tested. The prevalence of Campylobacter colonized broiler flocks was 67%. The contamination of meat at retail was 59%. Both semi-automated and wet market processing resulted to contaminate the broiler neck skins to the levels of 27.4% and 48%, respectively. When Campylobacter-free broiler flocks were processed in semi-automated facilities 15% (5/33) of neck skin samples became contaminated by the end of processing whereas 25% (2/8) became contaminated after wet market processing. Characterization of isolates revealed a higher proportion of C. coli compared to C. jejuni. Higher proportions of isolates were resistant to important antimicrobials. This study shows the importance of Campylobacter in poultry industry in Sri Lanka and the need for controlling antimicrobial resistance. PMID:29186018

  18. Integrated Multi-process Microfluidic Systems for Automating Analysis

    PubMed Central

    Yang, Weichun; Woolley, Adam T.

    2010-01-01

    Microfluidic technologies have been applied extensively in rapid sample analysis. Some current challenges for standard microfluidic systems are relatively high detection limits, and reduced resolving power and peak capacity compared to conventional approaches. The integration of multiple functions and components onto a single platform can overcome these separation and detection limitations of microfluidics. Multiplexed systems can greatly increase peak capacity in multidimensional separations and can increase sample throughput by analyzing many samples simultaneously. On-chip sample preparation, including labeling, preconcentration, cleanup and amplification, can all serve to speed up and automate processes in integrated microfluidic systems. This paper summarizes advances in integrated multi-process microfluidic systems for automated analysis, their benefits and areas for needed improvement. PMID:20514343

  19. Flexible Automation System for Determination of Elemental Composition of Incrustations in Clogged Biliary Endoprostheses Using ICP-MS.

    PubMed

    Fleischer, Heidi; Ramani, Kinjal; Blitti, Koffi; Roddelkopf, Thomas; Warkentin, Mareike; Behrend, Detlef; Thurow, Kerstin

    2018-02-01

    Automation systems are well established in industries and life science laboratories, especially in bioscreening and high-throughput applications. An increasing demand of automation solutions can be seen in the field of analytical measurement in chemical synthesis, quality control, and medical and pharmaceutical fields, as well as research and development. In this study, an automation solution was developed and optimized for the investigation of new biliary endoprostheses (stents), which should reduce clogging after implantation in the human body. The material inside the stents (incrustations) has to be controlled regularly and under identical conditions. The elemental composition is one criterion to be monitored in stent development. The manual procedure was transferred to an automated process including sample preparation, elemental analysis using inductively coupled plasma mass spectrometry (ICP-MS), and data evaluation. Due to safety issues, microwave-assisted acid digestion was executed outside of the automation system. The performance of the automated process was determined and validated. The measurement results and the processing times were compared for both the manual and the automated procedure. Finally, real samples of stent incrustations and pig bile were analyzed using the automation system.

  20. Plasma cortisol and noradrenalin concentrations in pigs: automated sampling of freely moving pigs housed in PigTurn versus manually sampled and restrained pigs

    USDA-ARS?s Scientific Manuscript database

    Minimizing the effects of restraint and human interaction on the endocrine physiology of animals is essential for collection of accurate physiological measurements. Our objective was to compare stress-induced cortisol (CORT) and noradrenalin (NorA) responses in automated versus manual blood sampling...

  1. Sample Preparation and Mounting of Drosophila Embryos for Multiview Light Sheet Microscopy.

    PubMed

    Schmied, Christopher; Tomancak, Pavel

    2016-01-01

    Light sheet fluorescent microscopy (LSFM), and in particular its most widespread flavor Selective Plane Illumination Microscopy (SPIM), promises to provide unprecedented insights into developmental dynamics of entire living systems. By combining minimal photo-damage with high imaging speed and sample mounting tailored toward the needs of the specimen, it enables in toto imaging of embryogenesis with high spatial and temporal resolution. Drosophila embryos are particularly well suited for SPIM imaging because the volume of the embryo does not change from the single cell embryo to the hatching larva. SPIM microscopes can therefore image Drosophila embryos embedded in rigid media, such as agarose, from multiple angles every few minutes from the blastoderm stage until hatching. Here, we describe sample mounting strategies to achieve such a recording. We also provide detailed protocols to realize multiview, long-term, time-lapse recording of Drosophila embryos expressing fluorescent markers on the commercially available Zeiss Lightsheet Z.1 microscope and the OpenSPIM.

  2. Rapid mounting of adult Drosophila structures in Hoyer's medium.

    PubMed

    Stern, David L; Sucena, Elio

    2012-01-01

    The Drosophila cuticle carries a rich array of morphological details. Thus, cuticle examination has had a central role in the history of genetics. This protocol describes a procedure for mounting adult cuticles in Hoyer's medium, a useful mountant for both larval and adult cuticles. The medium digests soft tissues rapidly, leaving the cuticle cleared for observation. In addition, samples can be transferred directly from water to Hoyer's medium. However, specimens mounted in Hoyer's medium degrade over time. For example, the fine denticles on the larval dorsum are best observed soon after mounting; they begin to fade after 1 week, and can disappear completely after several months. More robust features, such as the ventral denticle belts, will persist for a longer period of time. Because adults cannot profitably be mounted whole in Hoyer's medium, some dissection is necessary.

  3. Geothermal Potential Based on Physical Characteristics of the Region (Case Study: Mount Karang, Pandeglang Regency and Banten Province)

    NASA Astrophysics Data System (ADS)

    Russel, Fhillipo; Damayanti, Astrid; Pin, Tjiong Giok

    2018-02-01

    This research is about geothermal potential of Mount Karang, Banten Province which is based on the characteristics of the region. This research method used is geochemistry sample of hot springs and integrated with GIS method for spatial of geothermal potential. Based on the geothermal potential, Mount Karang is divided into three regions, ie high potential, normal potential, and low potential. The high geothermal potential region covers an area of 24.16 Km2 and which there are Cisolong and Banjar 2 hot springs. The normal potential covers Kawah hot spring. Index of the fault of Mount Karang region is one of the significant physical characteristics to determine geothermal potential.

  4. Impact of Mount St. Helens eruption on hydrology and water quality

    NASA Technical Reports Server (NTRS)

    Bonelli, J. E.; Taylor, H. E.; Klein, J. M.

    1982-01-01

    The 1980 eruptions of Mount St. Helens in southeast Washington resulted in a pronounced effect on the surface and ground water resources of the state. In response to the volcanic activity, the U.S. Geological Survey intensified statewide surface and ground water sampling programs to determine the nature and magnitude of the volcanic-induced variations. Streams to the east of Mount St. Helens received the major ash fallout. Chemical effects were best noted in smaller streams sampled 60 to 70 miles northeast of Mount St. Helens. The chemical variations observed were pronounced but short lived. Sulfate and chloride increases in anionic composition were prevalent immediately following the eruption; however, the original bicarbonate predominance was again attained within several days. Suspended iron and aluminum concentrations were similarly elevated during the period of greatest ash deposition (highest turbidity); however, the dissolved concentrations remained relatively constant. Depressions of pH were minor and short lived. Streams draining to the south, tributaries to the Columbia river, showed little observable changes in water chemistry. Streams draining to the west (Toutle river and its tributaries) were compositionally affected by the various volcanic activities. Chloride and sulfate anion percentage exceeded the bicarbonate percentage up to one month following the eruption period. Streams and lakes sampled in the immediate vicinity of Mount St. Helens, in addition to trace metals, contained organic compounds derived from decomposing wood buried in the debris deposits. This organic material may constitute a significant source of organic compounds to surface and ground water for some time to come.

  5. Virtual automation.

    PubMed

    Casis, E; Garrido, A; Uranga, B; Vives, A; Zufiaurre, C

    2001-01-01

    Total laboratory automation (TLA) can be substituted in mid-size laboratories by a computer sample workflow control (virtual automation). Such a solution has been implemented in our laboratory using PSM, software developed in cooperation with Roche Diagnostics (Barcelona, Spain), to this purpose. This software is connected to the online analyzers and to the laboratory information system and is able to control and direct the samples working as an intermediate station. The only difference with TLA is the replacement of transport belts by personnel of the laboratory. The implementation of this virtual automation system has allowed us the achievement of the main advantages of TLA: workload increase (64%) with reduction in the cost per test (43%), significant reduction in the number of biochemistry primary tubes (from 8 to 2), less aliquoting (from 600 to 100 samples/day), automation of functional testing, drastic reduction of preanalytical errors (from 11.7 to 0.4% of the tubes) and better total response time for both inpatients (from up to 48 hours to up to 4 hours) and outpatients (from up to 10 days to up to 48 hours). As an additional advantage, virtual automation could be implemented without hardware investment and significant headcount reduction (15% in our lab).

  6. Automated Fast Screening Method for Cocaine Identification in Seized Drug Samples Using a Portable Fourier Transform Infrared (FT-IR) Instrument.

    PubMed

    Mainali, Dipak; Seelenbinder, John

    2016-05-01

    Quick and presumptive identification of seized drug samples without destroying evidence is necessary for law enforcement officials to control the trafficking and abuse of drugs. This work reports an automated screening method to detect the presence of cocaine in seized samples using portable Fourier transform infrared (FT-IR) spectrometers. The method is based on the identification of well-defined characteristic vibrational frequencies related to the functional group of the cocaine molecule and is fully automated through the use of an expert system. Traditionally, analysts look for key functional group bands in the infrared spectra and characterization of the molecules present is dependent on user interpretation. This implies the need for user expertise, especially in samples that likely are mixtures. As such, this approach is biased and also not suitable for non-experts. The method proposed in this work uses the well-established "center of gravity" peak picking mathematical algorithm and combines it with the conditional reporting feature in MicroLab software to provide an automated method that can be successfully employed by users with varied experience levels. The method reports the confidence level of cocaine present only when a certain number of cocaine related peaks are identified by the automated method. Unlike library search and chemometric methods that are dependent on the library database or the training set samples used to build the calibration model, the proposed method is relatively independent of adulterants and diluents present in the seized mixture. This automated method in combination with a portable FT-IR spectrometer provides law enforcement officials, criminal investigators, or forensic experts a quick field-based prescreening capability for the presence of cocaine in seized drug samples. © The Author(s) 2016.

  7. Mantle and Crustal Sources of Carbon, Nitrogen, and Noble gases in Cascade-Range and Aleutian-Arc Volcanic gases

    USGS Publications Warehouse

    Symonds, Robert B.; Poreda, Robert J.; Evans, William C.; Janik, Cathy J.; Ritchie, Beatrice E.

    2003-01-01

    Here we report anhydrous chemical (CO2, H2S, N2, H2, CH4, O2, Ar, He, Ne) and isotopic (3He/4He, 40Ar/36Ar, δ13C of CO2, δ13C of CH4, δ15N) compositions of virtually airfree gas samples collected between 1994 and 1998 from 12 quiescent but potentially restless volcanoes in the Cascade Range and Aleutian Arc (CRAA). Sample sites include ≤173°C fumaroles and springs at Mount Shasta, Mount Hood, Mount St. Helens, Mount Rainier, Mount Baker, Augustine Volcano, Mount Griggs, Trident, Mount Mageik, Aniakchak Crater, Akutan, and Makushin. The chemical and isotopic data generally point to magmatic (CO2, Ar, He), shallow crustal sedimentary (hereafter, SCS) (CO2, N2, CH4), crustal (He), and meteoric (N2, Ar) sources of volatiles. CH4 clearly comes from SCS rocks in the subvolcanic systems because CH4 cannot survive the higher temperatures of deeper potential sources. Further evidence for a SCS source for CH4 as well as for non-mantle CO2 and non-meteoric N2 comes from isotopic data that show wide variations between volcanoes that are spatially very close and similar isotopic signatures from volcanoes from very disparate areas. Our results are in direct opposition to many recent studies on other volcanic arcs (Kita and others, 1993; Sano and Marty, 1995; Fischer and others, 1998), in that they point to a dearth of subducted components of CO2 and N2 in the CRAA discharges. Either the CRAA volcanoes are fundamentally different from volcanoes in other arcs or we need to reevaluate the significance of subducted C and N recycling in convergent-plate volcanoes.

  8. Microbiology of beef carcasses before and after slaughterline automation.

    PubMed Central

    Whelehan, O. P.; Hudson, W. R.; Roberts, T. A.

    1986-01-01

    The bacterial status of beef carcasses at a commercial abattoir was monitored before and after slaughterline automation. Bacterial counts did not differ significantly overall (P greater than 0.05) between the original manual line and the automated line for either morning or afternoon slaughter. On the manual line counts in the morning were lower than those from carcasses slaughtered in the afternoon, but on the automated line there was no difference between morning and afternoon counts. Due to highly significant line X sample site interaction for both morning and afternoon counts, overall differences among sample sites were not found by analysis of variance. However, principal components analysis revealed a significant shift in bacterial contamination among some sites due to slaughterline changes. The incidence of Enterobacteriaceae increased marginally following automation. PMID:3701039

  9. Scrubbing masks magmatic degassing during repose at Cascade-Range and Aleutian-Arc volcanoes

    USGS Publications Warehouse

    Symonds, Robert B.; Janik, C.J.; Evans, William C.; Ritchie, B.E.; Counce, Dale; Poreda, R.J.; Iven, Mark

    2003-01-01

    Between 1992 and 1998, we sampled gas discharges from ≤173°C fumaroles and springs at 12 quiescent but potentially restless volcanoes in the Cascade Range and Aleutian Arc (CRAA) including Mount Shasta, Mount Hood, Mount St. Helens, Mount Rainier, Mount Baker, Augustine Volcano, Mount Griggs, Trident, Mount Mageik, Aniakchak Crater, Akutan, and Makushin. For each site, we collected and analyzed samples to characterize the chemical (H2O, CO2, H2S, N2, CH4, H2, HCl, HF, NH3, Ar, O2, He) and isotopic (δ13C of CO2, 3He/4He, 40Ar/36Ar, δ34S, δ13C of CH4, δ15N, and δD and δ18O of water) compositions of the gas discharges, and to create baseline data for comparison during future unrest. The chemical and isotopic data show that these gases contain a magmatic component that is heavily modified from scrubbing by deep hydrothermal (150° - 350°C) water (primary scrubbing) and shallow meteoric water (secondary scrubbing). The impact of scrubbing is most pronounced in gas discharges from bubbling springs; gases from boiling-point fumaroles and superheated vents show progressively less impact from scrubbing. The most effective strategies for detecting gas precursors to future CRAA eruptions are to measure periodically the emission rates of CO2 and SO2, which have low and high respective solubilities in water, and to monitor continuously CO2 concentrations in soils around volcanic vents. Timely resampling of fumaroles can augment the geochemical surveillance program by watching for chemical changes associated with drying of fumarolic pathways (all CRAA sites), increases in gas geothermometry temperatures (Mount Mageik, Trident, Mount Baker, Mount Shasta), changes in δ13C of CO2 affiliated with magma movement (all CRAA site), and increases in 3He/4He coupled with intrusion of new magma (Mount Rainier, Augustine Volcano, Makushin, Mount Shasta). Repose magmatic degassing may discharge substantial amounts of S and Cl into the edifices of Mount Baker and several other CRAA volcanoes that is trapped by primary and secondary scrubbing. The consequent acidic fluids produce ongoing alteration in the 0.2- to 3-km-deep hydrothermal systems and in fields of boiling-point fumaroles near the surface. Such alteration may influence edifice stability and contribute to the formation of more-hazardous cohesive debris flows. In particular, we recommend further investigation of the volume, extent, and hazards of hydrothermal alteration at Mount Baker. Other potential hazards associated with the CRAA volcano hydrothermal systems include hydrothermal eruptions and, for deeper systems intruded by magma, deep-seated edifice collapse.

  10. Geochemical constraints on volatile sources and subsurface conditions at Mount Martin, Mount Mageik, and Trident Volcanoes, Katmai Volcanic Cluster, Alaska

    NASA Astrophysics Data System (ADS)

    Lopez, T.; Tassi, F.; Aiuppa, A.; Galle, B.; Rizzo, A. L.; Fiebig, J.; Capecchiacci, F.; Giudice, G.; Caliro, S.; Tamburello, G.

    2017-11-01

    We use the chemical and isotopic composition of volcanic gases and steam condensate, in situ measurements of plume composition and remote measurements of SO2 flux to constrain volatile sources and characterize subvolcanic conditions at three persistently degassing and seismically active volcanoes within the Katmai Volcanic Cluster (KVC), Alaska: Mount Martin, Mount Mageik and Trident. In situ plume measurements of gas composition were collected at all three volcanoes using MultiGAS instruments to calculate gas ratios (e.g. CO2/H2S, SO2/H2S and H2O/H2S), and remote measurements of SO2 column density were collected from Mount Martin and Mount Mageik by ultraviolet spectrometer systems to calculate SO2 fluxes. Fumaroles were directly sampled for chemical and isotopic composition from Mount Mageik and Trident. Mid Ocean Ridge Basalt (MORB)-like 3He/4He ratios ( 7.2-7.6 Rc/RA) within Mount Mageik and Trident's fumarole emissions and a moderate SO2 flux ( 75 t/d) from Mount Martin, combined with gas compositions dominated by H2O, CO2 and H2S from all three volcanoes, indicate magma degassing and active hydrothermal systems in the subsurface of these volcanoes. Mount Martin's gas emissions have the lowest CO2/H2S ratio ( 2-4) and highest SO2 flux compared to the other KVC volcanoes, indicative of shallow magma degassing. Geothermometry techniques applied to Mount Mageik and Trident's fumarolic gas compositions suggest that their hydrothermal reservoirs are located at depths of 0.2 and 4 km below the surface, respectively. Observations of an unusually reducing gas composition at Trident and organic material in the near-surface soils suggest that thermal decomposition of sediments may be influencing gas composition. When the measured gas compositions from Mount Mageik and Trident are compared with previous samples collected in the late 1990's, relatively stable magmatic-hydrothermal conditions are inferred for Mount Mageik, while gradual degassing of residual magma and contamination by shallow crustal fluids is inferred for Trident. The isotopic composition of volcanic gases emitted from Mount Mageik and Trident reflect mixing of subducted slab, mantle and crustal volatile sources, with organic sediment and carbonate being the predominant sources. Considering the close proximity of the target volcanoes in comparison with the depth to the subducted slab we speculate that Aleutian Arc volatiles are fed by a relatively homogeneous subducted fluid and that much of the apparent variability in volatile provenance can be explained by shallow crustal volatile sources and/or processes.

  11. The May 25-27 2005 Mount Logan Storm: Implications for the reconstruction of the climate signal contained in Gulf of Alaska Ice Cores

    NASA Astrophysics Data System (ADS)

    Moore, K.; Holdsworth, G.

    2006-12-01

    In late May 2005, 3 climbers were immobilized at 5400 m on Mount Logan, Canada`s highest mountain, by the high impact weather associated with an extratropical cyclone over the Gulf of Alaska. Rescue operations were hindered by the high winds, cold temperatures, and heavy snowfall associated with the storm. Ultimately, the climbers were rescued after the weather cleared. Just prior to the storm, two automated weather stations had been deployed on the mountain as part of a research program aimed at interpreting the climate signal contained in summit ice cores. These data provide a unique and hitherto unobtainable record of the high elevation meteorological conditions associated with a severe extratropical cyclone. In this talk, data from these weather stations along with surface and sounding data from the nearby town of Yakutat Alaska, satellite imagery and the NCEP reanalysis are used to characterize the synoptic-scale conditions associated with this storm. Particular emphasis is placed on the water vapor transport associated with this storm. The authors show that during this event, subtropical moisture was transported northwards towards the Mount Logan region. The magnitude of this transport into the Gulf of Alaska was exceeded only 1% of the time during the months of May and June over the period 1948-2005. As a result, the magnitude of the precipitable water field in the Gulf of Alaska region attained values usually found in the tropics. An atmospheric moisture budget analysis indicates that most of the moisture advected into the Mount Logan region was pre-existing water vapor already in the subtropical atmosphere and was not water vapor evaporated from the surface during the evolution of the storm. Implications of this moisture source for our understanding of the water isotopic climate signal in the Mount Logan ice cores will be discussed.

  12. Automated extraction of DNA from biological stains on fabric from crime cases. A comparison of a manual and three automated methods.

    PubMed

    Stangegaard, Michael; Hjort, Benjamin B; Hansen, Thomas N; Hoflund, Anders; Mogensen, Helle S; Hansen, Anders J; Morling, Niels

    2013-05-01

    The presence of PCR inhibitors in extracted DNA may interfere with the subsequent quantification and short tandem repeat (STR) reactions used in forensic genetic DNA typing. DNA extraction from fabric for forensic genetic purposes may be challenging due to the occasional presence of PCR inhibitors that may be co-extracted with the DNA. Using 120 forensic trace evidence samples consisting of various types of fabric, we compared three automated DNA extraction methods based on magnetic beads (PrepFiler Express Forensic DNA Extraction Kit on an AutoMate Express, QIAsyphony DNA Investigator kit either with the sample pre-treatment recommended by Qiagen or an in-house optimized sample pre-treatment on a QIAsymphony SP) and one manual method (Chelex) with the aim of reducing the amount of PCR inhibitors in the DNA extracts and increasing the proportion of reportable STR-profiles. A total of 480 samples were processed. The highest DNA recovery was obtained with the PrepFiler Express kit on an AutoMate Express while the lowest DNA recovery was obtained using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen. Extraction using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen resulted in the lowest percentage of PCR inhibition (0%) while extraction using manual Chelex resulted in the highest percentage of PCR inhibition (51%). The largest number of reportable STR-profiles was obtained with DNA from samples extracted with the PrepFiler Express kit (75%) while the lowest number was obtained with DNA from samples extracted using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen (41%). Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  13. Human anti-HIV IgM detection by the OraQuick ADVANCE® Rapid HIV 1/2 Antibody Test.

    PubMed

    Guillon, Geraldine; Yearwood, Graham; Snipes, Casey; Boschi, Daniel; Reed, Michael R

    2018-01-01

    The Centers for Disease Control and Prevention (CDC) and many public health jurisdictions continue to advocate for the most sensitive rapid HIV test that is available. Currently, the recommendation is to utilize tests that can detect HIV infection biomarkers within 30 days of infection, when initial immune responses are mounted. The infected patient's IgM response is often used to detect acute infection within a 20-25 days window after infection. This requirement applies to lab-based testing with automated analyzers and rapid, point of care (POC) testing used for screening in a non-clinical setting. A recent study has demonstrated that POC tests using a Protein A-based detection system can detect samples with predominantly HIV-1 IgM reactivity (Moshgabadi et al., 2015). The OraQuick ADVANCE ® Rapid HIV-1/2 Antibody Test (OraQuick ADVANCE ®) also uses Protein A as the detection protein in the antibody-binding colloidal gold conjugate, so it is expected that the OraQuick ADVANCE ® Test will also detect samples with predominantly IgM reactivity. This report definitively demonstrates that the OraQuick ADVANCE ® Test can detect IgM antibodies during an acute infection window period of approximately 20-25 days after infection, and is therefore suitable for use in testing environments requiring adherence to current CDC recommendations.

  14. Development of an automated pre-sampling plan for construction projects : final report.

    DOT National Transportation Integrated Search

    1983-03-01

    The development of an automated pre-sampling plan was undertaken to free the district construction personnel from the cumbersome and time-consuming task of preparing such plans manually. A computer program was written and linked to a data file which ...

  15. Development of automated high throughput single molecular microfluidic detection platform for signal transduction analysis

    NASA Astrophysics Data System (ADS)

    Huang, Po-Jung; Baghbani Kordmahale, Sina; Chou, Chao-Kai; Yamaguchi, Hirohito; Hung, Mien-Chie; Kameoka, Jun

    2016-03-01

    Signal transductions including multiple protein post-translational modifications (PTM), protein-protein interactions (PPI), and protein-nucleic acid interaction (PNI) play critical roles for cell proliferation and differentiation that are directly related to the cancer biology. Traditional methods, like mass spectrometry, immunoprecipitation, fluorescence resonance energy transfer, and fluorescence correlation spectroscopy require a large amount of sample and long processing time. "microchannel for multiple-parameter analysis of proteins in single-complex (mMAPS)"we proposed can reduce the process time and sample volume because this system is composed by microfluidic channels, fluorescence microscopy, and computerized data analysis. In this paper, we will present an automated mMAPS including integrated microfluidic device, automated stage and electrical relay for high-throughput clinical screening. Based on this result, we estimated that this automated detection system will be able to screen approximately 150 patient samples in a 24-hour period, providing a practical application to analyze tissue samples in a clinical setting.

  16. Support services for the automative gas turbine project

    NASA Technical Reports Server (NTRS)

    Golec, T. (Editor)

    1981-01-01

    Support was provided to DOE and NASA in their efforts to inform industry, the public, and Government on the benefits and purpose of the gas turbine programs through demonstrations and exhibits. Tasks were carried out for maintenance, repair, and retrofit of the experimental gas turbine engines being used by NASA in their gas turbine technology programs and in program demonstrations. Limited support testing was conducted at Chrysler in which data were generated on air bearing rotor shaft dynamics, heavy duty variable sheave rubber belts, high temperature elastomer regenerator drive mounting and graphite regenerator seal friction characteristics.

  17. Get ready for automated driving using Virtual Reality.

    PubMed

    Sportillo, Daniele; Paljic, Alexis; Ojeda, Luciano

    2018-06-08

    In conditionally automated vehicles, drivers can engage in secondary activities while traveling to their destination. However, drivers are required to appropriately respond, in a limited amount of time, to a take-over request when the system reaches its functional boundaries. Interacting with the car in the proper way from the first ride is crucial for car and road safety in general. For this reason, it is necessary to train drivers in a risk-free environment by providing them the best practice to use these complex systems. In this context, Virtual Reality (VR) systems represent a promising training and learning tool to properly familiarize drivers with the automated vehicle and allow them to interact with the novel equipment involved. In addition, Head-Mounted Display (HMD)-based VR (light VR) would allow for the easy deployment of such training systems in driving schools or car dealerships. In this study, the effectiveness of a light Virtual Reality training program for acquiring interaction skills in automated cars was investigated. The effectiveness of this training was compared to a user manual and a fixed-base simulator with respect to both objective and self-reported measures. Sixty subjects were randomly assigned to one of the systems in which they went through a training phase followed by a test drive in a high-end driving simulator. Results show that the training system affects the take-over performances. Moreover, self-reported measures indicate that the light VR training is preferred with respect to the other systems. Finally, another important outcome of this research is the evidence that VR plays a strategic role in the definition of the set of metrics for profiling proper driver interaction with the automated vehicle. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Ballistic impulse gauge

    DOEpatents

    Ault, Stanley K.

    1993-01-01

    A gauge for detecting the impulse generated in sample materials by X-rays or other impulse producing mechanisms utilizes a pair of flat annular springs to support a plunger relative to a housing which may itself be supported by a pair of flat annular springs in a second housing. The plunger has a mounting plate mounted on one end and at the other, a position or velocity transducer is mounted. The annular springs consist of an outer ring and an inner ring with at least three arcuate members connecting the outer ring with the inner ring.

  19. Ballistic impulse gauge

    DOEpatents

    Ault, S.K.

    1993-12-21

    A gauge for detecting the impulse generated in sample materials by X-rays or other impulse producing mechanisms utilizes a pair of flat annular springs to support a plunger relative to a housing which may itself be supported by a pair of flat annular springs in a second housing. The plunger has a mounting plate mounted on one end and at the other, a position or velocity transducer is mounted. The annular springs consist of an outer ring and an inner ring with at least three arcuate members connecting the outer ring with the inner ring. 4 figures.

  20. A Practical Approach for Recognizing Eating Moments with Wrist-Mounted Inertial Sensing

    PubMed Central

    Thomaz, Edison; Essa, Irfan; Abowd, Gregory D.

    2018-01-01

    Recognizing when eating activities take place is one of the key challenges in automated food intake monitoring. Despite progress over the years, most proposed approaches have been largely impractical for everyday usage, requiring multiple on-body sensors or specialized devices such as neck collars for swallow detection. In this paper, we describe the implementation and evaluation of an approach for inferring eating moments based on 3-axis accelerometry collected with a popular off-the-shelf smartwatch. Trained with data collected in a semi-controlled laboratory setting with 20 subjects, our system recognized eating moments in two free-living condition studies (7 participants, 1 day; 1 participant, 31 days), with F-scores of 76.1% (66.7% Precision, 88.8% Recall), and 71.3% (65.2% Precision, 78.6% Recall). This work represents a contribution towards the implementation of a practical, automated system for everyday food intake monitoring, with applicability in areas ranging from health research and food journaling. PMID:29520397

  1. Visual cues for person-centered communication.

    PubMed

    Williams, Kristine; Harris, Brynn; Lueger, Amy; Ward, Kathleen; Wassmer, Rebecca; Weber, Amy

    2011-11-01

    Nursing home communication is frequently limited and task-focused and fails to affirm resident personhood. We tested the feasibility and effects of automated digital displays of resident photographs to remind staff (N = 11) of resident (n = 6) personhood. Historical photographs were displayed in digital photo frames mounted in each resident's room. To evaluate the intervention's effects, staff-resident conversations were audio-recorded prior to displaying the frames and repeated 2 weeks and 3 months later. Conversations were transcribed and statements were topic coded (task-focused vs. interpersonal). Staff person-centered talk increased from 11% to 32% (z = 2.37, p = .02) after the intervention and task-talk decreased from 64% to 40%. Resident interpersonal topics increased from 20% to 37%. Staff statements increased from 29 at baseline, to 37 postintervention, and 41 at 3-month follow-up and resident engagement and reminiscence also increased. Effects were reduced after 3 months. Automated photo displays are an easily implemented, low-cost intervention to promote person-centered communication.

  2. [The actual possibilities of robotic microscopy in analysis automation and laboratory telemedicine].

    PubMed

    Medovyĭ, V S; Piatnitskiĭ, A M; Sokolinskiĭ, B Z; Balugian, R Sh

    2012-10-01

    The article discusses the possibilities of automation microscopy complexes manufactured by Cellavision and MEKOS to perform the medical analyses of blood films and other biomaterials. The joint work of the complex and physician in the regimen of automatic load stages, screening, sampling and sorting on types with simple morphology, visual sorting of sub-sample with complex morphology provides significant increase of method sensitivity, load decrease and enhancement of physician work conditions. The information technologies, the virtual slides and laboratory telemedicine included permit to develop the representative samples of rare types and pathologies to promote automation methods and medical research targets.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Egorov, Oleg; O'Hara, Matthew J.; Grate, Jay W.

    An automated fluidic instrument is described that rapidly determines the total 99Tc content of aged nuclear waste samples, where the matrix is chemically and radiologically complex and the existing speciation of the 99Tc is variable. The monitor links microwave-assisted sample preparation with an automated anion exchange column separation and detection using a flow-through solid scintillator detector. The sample preparation steps acidify the sample, decompose organics, and convert all Tc species to the pertechnetate anion. The column-based anion exchange procedure separates the pertechnetate from the complex sample matrix, so that radiometric detection can provide accurate measurement of 99Tc. We developed amore » preprogrammed spike addition procedure to automatically determine matrix-matched calibration. The overall measurement efficiency that is determined simultaneously provides a self-diagnostic parameter for the radiochemical separation and overall instrument function. Continuous, automated operation was demonstrated over the course of 54 h, which resulted in the analysis of 215 samples plus 54 hly spike-addition samples, with consistent overall measurement efficiency for the operation of the monitor. A sample can be processed and measured automatically in just 12.5 min with a detection limit of 23.5 Bq/mL of 99Tc in low activity waste (0.495 mL sample volume), with better than 10% RSD precision at concentrations above the quantification limit. This rapid automated analysis method was developed to support nuclear waste processing operations planned for the Hanford nuclear site.« less

  4. Arc-Second Alignment of International X-Ray Observatory Mirror Segments in a Fixed Structure

    NASA Technical Reports Server (NTRS)

    Evans, Tyler, C.; Chan, Kai-Wing; Saha, Timo T.

    2010-01-01

    The optics for the International X-Ray Observatory (IXO) require alignment and integration of about fourteen thousand thin mirror segments to achieve the mission goal of 3.0 square meters of effective area at 1.25 keV with an angular resolution of five arc-seconds. These mirror segments are 0.4 mm thick, and 200 to 400 mm in size, which makes it hard to meet the strict angular resolution requirement of 5 arc-seconds for the telescope. This paper outlines the precise alignment, verification testing, and permanent bonding techniques developed at NASA's Goddard Space Flight Center (GSFC). These techniques are used to overcome the challenge of transferring thin mirror segments from a temporary mount to a fixed structure with arc-second alignment and minimal figure distortion. Recent advances in technology development in addition to the automation of several processes have produced significant results. Recent advances in the mirror fixture process known as the suspension mount has allowed for a mirror to be mounted to a fixture with minimal distortion. Once on the fixture, mirror segments have been aligned to around 5 arc-seconds which is halfway to the goal of 2.5 arc-seconds per mirror segment. This paper will highlight the recent advances in alignment, testing, and permanent bonding techniques as well as the results they have produced.

  5. Testing of Visual Field with Virtual Reality Goggles in Manual and Visual Grasp Modes

    PubMed Central

    Wroblewski, Dariusz; Francis, Brian A.; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas

    2014-01-01

    Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4–6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode. PMID:25050326

  6. Automated extraction for the analysis of 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH) in urine using a six-head probe Hamilton Microlab 2200 system and gas chromatography-mass spectrometry.

    PubMed

    Whitter, P D; Cary, P L; Leaton, J I; Johnson, J E

    1999-01-01

    An automated extraction scheme for the analysis of 11 -nor-delta9-tetrahydrocannabinol-9-carboxylic acid using the Hamilton Microlab 2200, which was modified for gravity-flow solid-phase extraction, has been evaluated. The Hamilton was fitted with a six-head probe, a modular valve positioner, and a peristaltic pump. The automated method significantly increased sample throughput, improved assay consistency, and reduced the time spent performing the extraction. Extraction recovery for the automated method was > 90%. The limit of detection, limit of quantitation, and upper limit of linearity were equivalent to the manual method: 1.5, 3.0, and 300 ng/mL, respectively. Precision at the 15-ng/mL cut-off was as follows: mean = 14.4, standard deviation = 0.5, coefficient of variation = 3.5%. Comparison of 38 patient samples, extracted by the manual and automated extraction methods, demonstrated the following correlation statistics: r = .991, slope 1.029, and y-intercept -2.895. Carryover was < 0.3% at 1000 ng/mL. Aliquoting/extraction time for the automated method (48 urine samples) was 50 min, and the manual procedure required approximately 2.5 h. The automated aliquoting/extraction method on the Hamilton Microlab 2200 and its use in forensic applications are reviewed.

  7. Apparatus for sampling and characterizing aerosols

    DOEpatents

    Dunn, Patrick F.; Herceg, Joseph E.; Klocksieben, Robert H.

    1986-01-01

    Apparatus for sampling and characterizing aerosols having a wide particle size range at relatively low velocities may comprise a chamber having an inlet and an outlet, the chamber including: a plurality of vertically stacked, successive particle collection stages; each collection stage includes a separator plate and a channel guide mounted transverse to the separator plate, defining a labyrinthine flow path across the collection stage. An opening in each separator plate provides a path for the aerosols from one collection stage to the next. Mounted within each collection stage are one or more particle collection frames.

  8. Validating Mobile Electroencephalographic Systems for Integration into the PhyCORE and Application in Clinical Settings

    DTIC Science & Technology

    2016-09-26

    placement. The preamplifier mounted on top of the headset samples EEG signals at 300 Hz; it then transmits the raw EEG data via Bluetooth ® to a data...The preamplifier mounted on the back of the headset samples EEG signals at 256 Hz and then transmits the raw EEG data via Bluetooth ® to a data...electrooculography. The batteries will last 6 hours using Bluetooth ® or 16 hours if data are recorded directly onto a secure digital card. A three-axis

  9. Seasonal distribution and aerial surveys of mountain goats in Mount Rainier, North Cascades, and Olympic National Parks, Washington

    USGS Publications Warehouse

    Jenkins, Kurt; Beirne, Katherine; Happe, Patricia; Hoffman, Roger; Rice, Cliff; Schaberl, Jim

    2011-01-01

    We described the seasonal distribution of Geographic Positioning System (GPS)-collared mountain goats (Oreamnos americanus) in Mount Rainier, North Cascades, and Olympic National Parks to evaluate aerial survey sampling designs and provide general information for park managers. This work complemented a companion study published elsewhere of aerial detection biases of mountain goat surveys in western Washington. Specific objectives reported here were to determine seasonal and altitudinal movements, home range distributions, and temporal dynamics of mountain goat movements in and out of aerial survey sampling frames established within each park. We captured 25 mountain goats in Mount Rainier (9), North Cascades (5), and Olympic (11) National Parks, and fitted them with GPS-collars programmed to obtain 6-8 locations daily. We obtained location data on 23 mountain goats for a range of 39-751 days from 2003 to 2008. Altitudinal distributions of GPS-collared mountain goats varied individually and seasonally, but median altitudes used by individual goats during winter ranged from 817 to 1,541 meters in Olympic and North Cascades National Parks, and 1,215 to 1,787 meters in Mount Rainier National Park. Median altitudes used by GPS-collared goats during summer ranged from 1,312 to 1,819 meters in Olympic and North Cascades National Parks, and 1,780 to 2,061 meters in Mount Rainier National Park. GPS-collared mountain goats generally moved from low-altitude winter ranges to high-altitude summer ranges between June 11 and June 19 (range April 24-July 3) and from summer to winter ranges between October 26 and November 9 (range September 11-December 23). Seasonal home ranges (95 percent of adaptive kernel utilization distribution) of males and female mountain goats were highly variable, ranging from 1.6 to 37.0 kilometers during summers and 0.7 to 9.5 kilometers during winters. Locations of GPS-collared mountain goats were almost 100 percent within the sampling frame used for mountain goat surveys in Mount Rainier National Park, whereas generally greater than 80 and greater than 60 percent of locations were within sampling units delineated in North Cascades and Olympic National Parks, respectively. Presence of GPS-collared mountain goats within the sampling frame of Olympic National Park varied by diurnal period (midday versus crepuscular), survey season (July versus September), and the interaction of diurnal period and survey season. Aerial surveys conducted in developing a sightability model for mountain goat aerial surveys indicated mean detection probabilities of 0.69, 0.76, and 0.87 in North Cascades, Olympic, and Mount Rainier National Parks, respectively. Higher detection probabilities in Mount Rainier likely reflected larger group sizes and more open habitat conditions than in North Cascades and Olympic National Parks. Use of sightability models will reduce biases of population estimates in each park, but resulting population estimates must still be considered minimum population estimates in Olympic and North Cascades National Parks because the current sampling frames do not encompass those populations completely. Because mountain goats were reliably present within the sampling frame in Mount Rainier National Park, we found no compelling need to adjust mountain goat survey boundaries in that park. Expanding survey coverage in North Cascades and Olympic National Parks to more reliably encompass the altitudinal distribution of mountain goats during summer would enhance population estimation accuracy in the future. Lowering the altitude boundary of mountain goat survey units by as little as 100 meters to 1,425 meters in Olympic National Park would increase mountain goat presence within the survey and reduce variation in counts related to movements of mountain goats outside the survey boundaries.

  10. Can the Roche hemolysis index be used for automated determination of cell-free hemoglobin? A comparison to photometric assays.

    PubMed

    Petrova, Darinka Todorova; Cocisiu, Gabriela Ariadna; Eberle, Christoph; Rhode, Karl-Heinz; Brandhorst, Gunnar; Walson, Philip D; Oellerich, Michael

    2013-09-01

    The aim of this study was to develop a novel method for automated quantification of cell-free hemoglobin (fHb) based on the HI (Roche Diagnostics). The novel fHb method based on the HI was correlated with fHb measured using the triple wavelength methods of both Harboe [fHb, g/L = (0.915 * HI + 2.634)/100] and Fairbanks et al. [fHb, g/L = (0.917 * HI + 2.131)/100]. fHb concentrations were estimated from the HI using the Roche Modular automated platform in self-made and commercially available quality controls, as well as samples from a proficiency testing scheme (INSTAND). The fHb using Roche automated HI results were then compared to results obtained using the traditional spectrophotometric assays for one hundred plasma samples with varying degrees of hemolysis, lipemia and/or bilirubinemia. The novel method using automated HI quantification on the Roche Modular clinical chemistry platform correlated well with results using the classical methods in the 100 patient samples (Harboe: r = 0.9284; Fairbanks et al.: r = 0.9689) and recovery was good for self-made controls. However, commercially available quality controls showed poor recovery due to an unidentified matrix problem. The novel method produced reliable determination of fHb in samples without interferences. However, poor recovery using commercially available fHb quality control samples currently greatly limits its usefulness. © 2013.

  11. The laboratory of the 1990s—Planning for total automation

    PubMed Central

    Brunner, Linda A.

    1992-01-01

    The analytical laboratory of the 1990s must be able to meet and accommodate the rapid evolution of modern-day technology. One such area is laboratory automation. Total automation may be seen as the coupling of computerized sample tracking, electronic documentation and data reduction with automated sample handling, preparation and analysis, resulting in a complete analytical procedure with minimal human involvement. Requirements may vary from one laboratory or facility to another, so the automation has to be flexible enough to cover a wide range of applications, and yet fit into specific niches depending on individual needs. Total automation must be planned for, well in advance, if the endeavour is to be a success. Space, laboratory layout, proper equipment, and the availability and access to necessary utilities must be taken into account. Adequate training and experience of the personnel working with the technology must also be ensured. In addition, responsibilities of installation, programming maintenance and operation have to be addressed. Proper time management and the efficient implementation and use of total automation are also crucial to successful operations. This paper provides insights into laboratory organization and requirements, as well as discussing the management issues that must be faced when automating laboratory procedures. PMID:18924925

  12. Development of automation software for neutron activation analysis process in Malaysian nuclear agency

    NASA Astrophysics Data System (ADS)

    Yussup, N.; Rahman, N. A. A.; Ibrahim, M. M.; Mokhtar, M.; Salim, N. A. A.; Soh@Shaari, S. C.; Azman, A.

    2017-01-01

    Neutron Activation Analysis (NAA) process has been established in Malaysian Nuclear Agency (Nuclear Malaysia) since 1980s. Most of the procedures established especially from sample registration to sample analysis are performed manually. These manual procedures carried out by the NAA laboratory personnel are time consuming and inefficient. Hence, a software to support the system automation is developed to provide an effective method to replace redundant manual data entries and produce faster sample analysis and calculation process. This paper describes the design and development of automation software for NAA process which consists of three sub-programs. The sub-programs are sample registration, hardware control and data acquisition; and sample analysis. The data flow and connection between the sub-programs will be explained. The software is developed by using National Instrument LabView development package.

  13. ICECAP: an integrated, general-purpose, automation-assisted IC50/EC50 assay platform.

    PubMed

    Li, Ming; Chou, Judy; King, Kristopher W; Jing, Jing; Wei, Dong; Yang, Liyu

    2015-02-01

    IC50 and EC50 values are commonly used to evaluate drug potency. Mass spectrometry (MS)-centric bioanalytical and biomarker labs are now conducting IC50/EC50 assays, which, if done manually, are tedious and error-prone. Existing bioanalytical sample preparation automation systems cannot meet IC50/EC50 assay throughput demand. A general-purpose, automation-assisted IC50/EC50 assay platform was developed to automate the calculations of spiking solutions and the matrix solutions preparation scheme, the actual spiking and matrix solutions preparations, as well as the flexible sample extraction procedures after incubation. In addition, the platform also automates the data extraction, nonlinear regression curve fitting, computation of IC50/EC50 values, graphing, and reporting. The automation-assisted IC50/EC50 assay platform can process the whole class of assays of varying assay conditions. In each run, the system can handle up to 32 compounds and up to 10 concentration levels per compound, and it greatly improves IC50/EC50 assay experimental productivity and data processing efficiency. © 2014 Society for Laboratory Automation and Screening.

  14. Automation of serum (1→3)-beta-D-glucan testing allows reliable and rapid discrimination of patients with and without candidemia.

    PubMed

    Prüller, Florian; Wagner, Jasmin; Raggam, Reinhard B; Hoenigl, Martin; Kessler, Harald H; Truschnig-Wilders, Martie; Krause, Robert

    2014-07-01

    Testing for (1→3)-beta-D-glucan (BDG) is used for detection of invasive fungal infection. However, current assays lack automation and the ability to conduct rapid single-sample testing. The Fungitell assay was adopted for automation and evaluated using clinical samples from patients with culture-proven candidemia and from culture-negative controls in duplicate. A comparison with the standard assay protocol was made in order to establish analytical specifications. With the automated protocol, the analytical measuring range was 8-2500 pg/ml of BDG, and precision testing resulted in coefficients of variation that ranged from 3.0% to 5.5%. Samples from 15 patients with culture-proven candidemia and 94 culture-negative samples were evaluated. All culture-proven samples showed BDG values >80 pg/ml (mean 1247 pg/ml; range, 116-2990 pg/ml), which were considered positive. Of the 94 culture-negative samples, 92 had BDG values <60 pg/ml (mean, 28 pg/ml), which were considered to be negative, and 2 samples were false-positive (≥80 pg/ml; up to 124 pg/ml). Results could be obtained within 45 min and showed excellent agreement with results obtained with the standard assay protocol. The automated Fungitell assay proved to be reliable and rapid for diagnosis of candidemia. It was demonstrated to be feasible and cost efficient for both single-sample and large-scale testing of serum BDG. Its 1-h time-to-result will allow better support for clinicians in the management of antifungal therapy. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Motion compensation for MRI-compatible patient-mounted needle guide device: estimation of targeting accuracy in MRI-guided kidney cryoablations

    NASA Astrophysics Data System (ADS)

    Tokuda, Junichi; Chauvin, Laurent; Ninni, Brian; Kato, Takahisa; King, Franklin; Tuncali, Kemal; Hata, Nobuhiko

    2018-04-01

    Patient-mounted needle guide devices for percutaneous ablation are vulnerable to patient motion. The objective of this study is to develop and evaluate a software system for an MRI-compatible patient-mounted needle guide device that can adaptively compensate for displacement of the device due to patient motion using a novel image-based automatic device-to-image registration technique. We have developed a software system for an MRI-compatible patient-mounted needle guide device for percutaneous ablation. It features fully-automated image-based device-to-image registration to track the device position, and a device controller to adjust the needle trajectory to compensate for the displacement of the device. We performed: (a) a phantom study using a clinical MR scanner to evaluate registration performance; (b) simulations using intraoperative time-series MR data acquired in 20 clinical cases of MRI-guided renal cryoablations to assess its impact on motion compensation; and (c) a pilot clinical study in three patients to test its feasibility during the clinical procedure. FRE, TRE, and success rate of device-to-image registration were mm, mm, and 98.3% for the phantom images. The simulation study showed that the motion compensation reduced the targeting error for needle placement from 8.2 mm to 5.4 mm (p  <  0.0005) in patients under general anesthesia (GA), and from 14.4 mm to 10.0 mm () in patients under monitored anesthesia care (MAC). The pilot study showed that the software registered the device successfully in a clinical setting. Our simulation study demonstrated that the software system could significantly improve targeting accuracy in patients treated under both MAC and GA. Intraprocedural image-based device-to-image registration was feasible.

  16. A compendium of controlled diffusion blades generated by an automated inverse design procedure

    NASA Technical Reports Server (NTRS)

    Sanz, Jose M.

    1989-01-01

    A set of sample cases was produced to test an automated design procedure developed at the NASA Lewis Research Center for the design of controlled diffusion blades. The range of application of the automated design procedure is documented. The results presented include characteristic compressor and turbine blade sections produced with the automated design code as well as various other airfoils produced with the base design method prior to the incorporation of the automated procedure.

  17. Automated Protein Biomarker Analysis: on-line extraction of clinical samples by Molecularly Imprinted Polymers

    NASA Astrophysics Data System (ADS)

    Rossetti, Cecilia; Świtnicka-Plak, Magdalena A.; Grønhaug Halvorsen, Trine; Cormack, Peter A. G.; Sellergren, Börje; Reubsaet, Léon

    2017-03-01

    Robust biomarker quantification is essential for the accurate diagnosis of diseases and is of great value in cancer management. In this paper, an innovative diagnostic platform is presented which provides automated molecularly imprinted solid-phase extraction (MISPE) followed by liquid chromatography-mass spectrometry (LC-MS) for biomarker determination using ProGastrin Releasing Peptide (ProGRP), a highly sensitive biomarker for Small Cell Lung Cancer, as a model. Molecularly imprinted polymer microspheres were synthesized by precipitation polymerization and analytical optimization of the most promising material led to the development of an automated quantification method for ProGRP. The method enabled analysis of patient serum samples with elevated ProGRP levels. Particularly low sample volumes were permitted using the automated extraction within a method which was time-efficient, thereby demonstrating the potential of such a strategy in a clinical setting.

  18. The use of MP3 recorders to log data from equine hoof mounted accelerometers.

    PubMed

    Parsons, K J; Wilson, A M

    2006-11-01

    MP3 recorders are readily available, small, lightweight and low cost, providing the potential for logging analogue hoof mounted accelerometer signals for the characterisation of equine locomotion. These, however, require testing in practice. To test whether 1) multiple MP3 recorders can maintain synchronisation, giving the ability to synchronise independent recorders for the logging of multiple limbs simultaneously; and 2) features of a foot mounted accelerometer signal attributable to foot-on and foot-off can be accurately identified from horse foot mounted accelerometers logged directly into an MP3 recorder. Three experiments were performed: 1) Maintenance of synchronisation was assessed by counting the number of samples recorded by each of 4 MP3 recorders while mounted on a trotting horse and over 2 consecutive 30 min periods in 8 recorders on a bench. 2) Foot-on and foot-off times obtained from manual transcription of MP3 logged data and directly logged accelerometer signal were compared. 3) MP3/accelerometer acquisition units were used to log accelerometer signals from racehorses during extended training sessions. Mean absolute error of synchronisation between MP3 recorders was 10 samples per million (compared to mean number of samples, range 1-32 samples per million). Error accumulation showed a linear correlation with time. Features attributable to foot on and foot off were equally identifiable from the MP3 recorded signal over a range of equine gaits. Multiple MP3 recorders can be synchronised and used as a relatively cheap, robust, reliable and accurate logging system when combined with an accelerometer and external battery for the specific application of the measurement of stride timing variables across the range of equine gaits during field locomotion. Footfall timings can be used to identify intervals between the fore and hind contacts, the identification of diagonal advanced placement and to calculate stride timing variables (stance time, protraction time and stride time). These parameters are invaluable for the characterisation and assessment of equine locomotion.

  19. Perchlorate and selected metals in water and soil within Mount Rushmore National Memorial, South Dakota, 2011–15

    USGS Publications Warehouse

    Hoogestraat, Galen K.; Rowe, Barbara L.

    2016-04-14

    Mount Rushmore National Memorial is located in the east-central part of the Black Hills area of South Dakota and is challenged to provide drinking water to about 3 million annual visitors and year-round park personnel. An environmental concern to water resources within Mount Rushmore National Memorial has been the annual aerial fireworks display at the memorial for the Independence Day holiday during 1998–2009. A major concern of park management is the contamination of groundwater and surface water by perchlorate, which is used as an oxidizing agent in firework displays. A study by the U.S. Geological Survey, in cooperation with the National Park Service, was completed to characterize the occurrence of perchlorate and selected metals (constituents commonly associated with fireworks) in groundwater and surface water within and adjacent to Mount Rushmore National Memorial during 2011–15. Concentrations of perchlorate and metals in 106 water samples (collected from 6 groundwater sites and 14 surface-water sites) and 11 soil samples (collected from 11 soil sites) are reported.Within the Mount Rushmore National Memorial boundary, perchlorate concentrations were greatest in the Lafferty Gulch drainage basin, ranging from less than 0.20 to 38 micrograms per liter (μg/L) in groundwater samples and from 2.2 to 54 μg/L in surface-water samples. Sites within the Starling Gulch drainage basin also had some evidence of perchlorate contamination, with concentrations ranging from 0.61 to 19 μg/L. All groundwater and surface-water samples within the unnamed tributary to Grizzly Bear Creek drainage basin and reference sites outside the park boundary had concentrations less than 0.20 μg/L. Perchlorate concentrations in samples collected at the 200-foot-deep production well (Well 1) ranged from 17 to 38 μg/L with a median of 23 μg/L, whereas perchlorate concentrations in samples from the 500-foot-deep production well (Well 2) ranged from 2.1 to 17 μg/L, with a median of 6.1 μg/L. Perchlorate concentrations in samples of the treated groundwater were similar to the concentrations from Well 1, which was the predominant source of the water supply at Mount Rushmore National Memorial during the study period (2011–15). Springflow upstream from the production wells in the West Fork Lafferty Gulch drainage had the greatest perchlorate concentrations, ranging from 21 to 54 μg/L. The groundwater site within Lafferty Gulch drainage basin but downstream from the park boundary also had a perchlorate concentration less than 0.20 μg/L in the one sample collected at the site. Water samples collected at reference sites generally had concentrations of metals within the same range of those sites within the Mount Rushmore National Memorial boundary, presenting little evidence of metal contamination due to anthropogenic factors within the park boundary. Soil samples were collected near most water sampling sites and within the Hall of Records Canyon where fireworks were launched. Perchlorate concentrations in soil were greatest in the West Fork Lafferty Gulch drainage and Hall of Records Canyon, which are topographically higher than the two groundwater wells.The perchlorate concentrations in groundwater and surface water within Lafferty Gulch drainage basin during 2011–15 were greater than the U.S. Environmental Protection Agency’s Interim Drinking Water Health Advisory benchmark of 15 μg/L. The perchlorate concentrations in the Mount Rushmore water supply relative to this benchmark are of concern; however, this health advisory is based on the assumption that consumers are using the supply as their primary water source and currently is not a regulated standard. The groundwater system at West Fork Lafferty Gulch is highly susceptible to contamination by way of recharge and is isolated from downstream movement by an intrusive body acting as a dam, which may explain why a contamination problem is not likely to disappear or disperse, as could happen in larger aquifer systems. The observed deposition of firework debris within Lafferty Gulch drainage basin coupled with the lack of alternative perchlorate sources indicates that past firework displays are the most probable source of perchlorate contamination.

  20. Automated direct-immersion solid-phase microextraction using crosslinked polymeric ionic liquid sorbent coatings for the determination of water pollutants by gas chromatography.

    PubMed

    Cordero-Vaca, María; Trujillo-Rodríguez, María J; Zhang, Cheng; Pino, Verónica; Anderson, Jared L; Afonso, Ana M

    2015-06-01

    Four different crosslinked polymeric ionic liquid (PIL)-based sorbent coatings were evaluated in an automated direct-immersion solid-phase microextraction method (automated DI-SPME) in combination with gas chromatography (GC). The crosslinked PIL coatings were based on vinyl-alkylimidazolium- (ViCnIm-) or vinylbenzyl-alkylimidazolium- (ViBzCnIm-) IL monomers, and di-(vinylimidazolium)dodecane ((ViIm)2C12-) or di-(vinylbenzylimidazolium)dodecane ((ViBzIm)2C12-) dicationic IL crosslinkers. In addition, a PIL-based hybrid coating containing multi-walled carbon nanotubes (MWCNTs) was also studied. The studied PIL coatings were covalently attached to derivatized nitinol wires and mounted onto the Supelco assembly to ensure automation when acting as SPME coatings. Their behavior was evaluated in the determination of a group of water pollutants, after proper optimization. A comparison was carried out with three common commercial SPME fibers. It was observed that those PILs containing a benzyl group in their structures, either in the IL monomer and crosslinker (PIL-1-1) or only in the crosslinker (PIL-0-1), were the most efficient sorbents for the selected analytes. The validation of the overall automated DI-SPME-GC-flame ionization detector (FID) method gave limits of detection down to 135 μg · L(-1) for p-cresol when using the PIL-1-1 and down to 270 μg · L(-1) when using the PIL-0-1; despite their coating thickness: ~2 and ~5 μm, respectively. Average relative recoveries with waters were of 85 ± 14 % and 87 ± 15 % for PIL-1-1 and PIL-0-1, respectively. Precision values as relative standard deviation were always lower than 4.9 and 7.6 % (spiked level between 10 and 750 μg · L(-1), as intra-day precision). Graphical Abstract Automated DI-SPME-GC-FID using crosslinked-PILs sorbent coatings for the determination of waterpollutants.

  1. Use of body-mounted cameras to enhance data collection: an evaluation of two arthropod sampling techniques

    USDA-ARS?s Scientific Manuscript database

    A study was conducted that compared the effectiveness of a sweepnet versus a vacuum suction device for collecting arthropods in cotton. The study differs from previous research in that body-mounted action cameras (B-MACs) were used to record the activity of the person conducting the collections. The...

  2. Cutaway line drawing of STS-34 middeck experiment Polymer Morphology (PM)

    NASA Technical Reports Server (NTRS)

    1989-01-01

    Cutaway line drawing shows components of STS-34 middeck experiment Polymer Morphology (PM). Components include the EAC, heat exchanger, sample cell control (SCC), sample cells, source, interferometer, electronics, carousel drive, infrared (IR) beam, and carousel. PM, a 3M-developed organic materials processing experiment, is designed to explore the effects of microgravity on polymeric materials as they are processed in space. The samples of polymeric materials being studied in the PM experiment are thin films (25 microns or less) approximately 25mm in diameter. The samples are mounted between two infrared transparent windows in a specially designed infrared cell that provides the capability of thermally processing the samples to 200 degrees Celsius with a high degree of thermal control. The samples are mounted on a carousel that allows them to be positioned, one at a time, in the infrared beam where spectra may be acquired. The Generic Electronics Module (GEM) provides all carousel and

  3. In situ location and U-Pb dating of small zircon grains in igneous rocks using laser ablation-inductively coupled plasma-quadrupole mass spectrometry

    NASA Astrophysics Data System (ADS)

    Sack, Patrick J.; Berry, Ron F.; Meffre, Sebastien; Falloon, Trevor J.; Gemmell, J. Bruce; Friedman, Richard M.

    2011-05-01

    A new U-Pb zircon dating protocol for small (10-50 μm) zircons has been developed using an automated searching method to locate zircon grains in a polished rock mount. The scanning electron microscope-energy-dispersive X ray spectrum-based automated searching method can routinely find in situ zircon grains larger than 5 μm across. A selection of these grains was ablated using a 10 μm laser spot and analyzed in an inductively coupled plasma-quadrupole mass spectrometer (ICP-QMS). The technique has lower precision (˜6% uncertainty at 95% confidence on individual spot analyses) than typical laser ablation ICP-MS (˜2%), secondary ion mass spectrometry (<1%), and isotope dilution-thermal ionization mass spectrometry (˜0.4%) methods. However, it is accurate and has been used successfully on fine-grained lithologies, including mafic rocks from island arcs, ocean basins, and ophiolites, which have traditionally been considered devoid of dateable zircons. This technique is particularly well suited for medium- to fine-grained mafic volcanic rocks where zircon separation is challenging and can also be used to date rocks where only small amounts of sample are available (clasts, xenoliths, dredge rocks). The most significant problem with dating small in situ zircon grains is Pb loss. In our study, many of the small zircons analyzed have high U contents, and the isotopic compositions of these grains are consistent with Pb loss resulting from internal α radiation damage. This problem is not significant in very young rocks and can be minimized in older rocks by avoiding high-U zircon grains.

  4. NASA Tech Briefs, November 2009

    NASA Technical Reports Server (NTRS)

    2009-01-01

    Topics covered include: Cryogenic Chamber for Servo-Hydraulic Materials Testing; Apparatus Measures Thermal Conductance Through a Thin Sample from Cryogenic to Room Temperature; Rover Attitude and Pointing System Simulation Testbed; Desktop Application Program to Simulate Cargo-Air-Drop Tests; Multimodal Friction Ignition Tester; Small-Bolt Torque-Tension Tester; Integrated Spacesuit Audio System Enhances Speech Quality and Reduces Noise; Hardware Implementation of a Bilateral Subtraction Filter; Simple Optoelectronic Feedback in Microwave Oscillators; Small X-Band Oscillator Antennas; Free-Space Optical Interconnect Employing VCSEL Diodes; Discrete Fourier Transform Analysis in a Complex Vector Space; Miniature Scroll Pumps Fabricated by LIGA; Self-Assembling, Flexible, Pre-Ceramic Composite Preforms; Flight-speed Integral Image Analysis Toolkit; Work Coordination Engine; Multi-Mission Automated Task Invocation Subsystem; Autonomously Calibrating a Quadrupole Mass Spectrometer; Determining Spacecraft Reaction Wheel Friction Parameters; Composite Silica Aerogels Opacified with Titania; Multiplexed Colorimetric Solid-Phase Extraction; Detecting Airborne Mercury by Use of Polymer/Carbon Films; Lattice-Matched Semiconductor Layers on Single Crystalline Sapphire Substrate; Pressure-Energized Seal Rings to Better Withstand Flows; Rollerjaw Rock Crusher; Microwave Sterilization and Depyrogenation System; Quantifying Therapeutic and Diagnostic Efficacy in 2D Microvascular Images; NiF2/NaF:CaF2/Ca Solid-State High-Temperature Battery Cells; Critical Coupling Between Optical Fibers and WGM Resonators; Microwave Temperature Profiler Mounted in a Standard Airborne Research Canister; Alternative Determination of Density of the Titan Atmosphere; Solar Rejection Filter for Large Telescopes; Automated CFD for Generation of Airfoil Performance Tables; Progressive Classification Using Support Vector Machines; Active Learning with Irrelevant Examples; A Data Matrix Method for Improving the Quantification of Element Percentages of SEM/EDX Analysis; Deployable Shroud for the International X-Ray Observatory; Improved Model of a Mercury Ring Damper; Optoelectronic pH Meter: Further Details; X-38 Advanced Sublimator; and Solar Simulator Represents the Mars Surface Solar Environment.

  5. Comprehensive automation of the solid phase extraction gas chromatographic mass spectrometric analysis (SPE-GC/MS) of opioids, cocaine, and metabolites from serum and other matrices.

    PubMed

    Lerch, Oliver; Temme, Oliver; Daldrup, Thomas

    2014-07-01

    The analysis of opioids, cocaine, and metabolites from blood serum is a routine task in forensic laboratories. Commonly, the employed methods include many manual or partly automated steps like protein precipitation, dilution, solid phase extraction, evaporation, and derivatization preceding a gas chromatography (GC)/mass spectrometry (MS) or liquid chromatography (LC)/MS analysis. In this study, a comprehensively automated method was developed from a validated, partly automated routine method. This was possible by replicating method parameters on the automated system. Only marginal optimization of parameters was necessary. The automation relying on an x-y-z robot after manual protein precipitation includes the solid phase extraction, evaporation of the eluate, derivatization (silylation with N-methyl-N-trimethylsilyltrifluoroacetamide, MSTFA), and injection into a GC/MS. A quantitative analysis of almost 170 authentic serum samples and more than 50 authentic samples of other matrices like urine, different tissues, and heart blood on cocaine, benzoylecgonine, methadone, morphine, codeine, 6-monoacetylmorphine, dihydrocodeine, and 7-aminoflunitrazepam was conducted with both methods proving that the analytical results are equivalent even near the limits of quantification (low ng/ml range). To our best knowledge, this application is the first one reported in the literature employing this sample preparation system.

  6. High-throughput sample processing and sample management; the functional evolution of classical cytogenetic assay towards automation.

    PubMed

    Ramakumar, Adarsh; Subramanian, Uma; Prasanna, Pataje G S

    2015-11-01

    High-throughput individual diagnostic dose assessment is essential for medical management of radiation-exposed subjects after a mass casualty. Cytogenetic assays such as the Dicentric Chromosome Assay (DCA) are recognized as the gold standard by international regulatory authorities. DCA is a multi-step and multi-day bioassay. DCA, as described in the IAEA manual, can be used to assess dose up to 4-6 weeks post-exposure quite accurately but throughput is still a major issue and automation is very essential. The throughput is limited, both in terms of sample preparation as well as analysis of chromosome aberrations. Thus, there is a need to design and develop novel solutions that could utilize extensive laboratory automation for sample preparation, and bioinformatics approaches for chromosome-aberration analysis to overcome throughput issues. We have transitioned the bench-based cytogenetic DCA to a coherent process performing high-throughput automated biodosimetry for individual dose assessment ensuring quality control (QC) and quality assurance (QA) aspects in accordance with international harmonized protocols. A Laboratory Information Management System (LIMS) is designed, implemented and adapted to manage increased sample processing capacity, develop and maintain standard operating procedures (SOP) for robotic instruments, avoid data transcription errors during processing, and automate analysis of chromosome-aberrations using an image analysis platform. Our efforts described in this paper intend to bridge the current technological gaps and enhance the potential application of DCA for a dose-based stratification of subjects following a mass casualty. This paper describes one such potential integrated automated laboratory system and functional evolution of the classical DCA towards increasing critically needed throughput. Published by Elsevier B.V.

  7. 21 CFR 864.5600 - Automated hematocrit instrument.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... measures the packed red cell volume of a blood sample to distinguish normal from abnormal states, such as anemia and erythrocytosis (an increase in the number of red cells). (b) Classification. Class II... § 864.5600 Automated hematocrit instrument. (a) Identification. An automated hematocrit instrument is a...

  8. 21 CFR 864.5600 - Automated hematocrit instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... measures the packed red cell volume of a blood sample to distinguish normal from abnormal states, such as anemia and erythrocytosis (an increase in the number of red cells). (b) Classification. Class II... § 864.5600 Automated hematocrit instrument. (a) Identification. An automated hematocrit instrument is a...

  9. 21 CFR 864.5600 - Automated hematocrit instrument.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... measures the packed red cell volume of a blood sample to distinguish normal from abnormal states, such as anemia and erythrocytosis (an increase in the number of red cells). (b) Classification. Class II... § 864.5600 Automated hematocrit instrument. (a) Identification. An automated hematocrit instrument is a...

  10. 21 CFR 864.5600 - Automated hematocrit instrument.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... measures the packed red cell volume of a blood sample to distinguish normal from abnormal states, such as anemia and erythrocytosis (an increase in the number of red cells). (b) Classification. Class II... § 864.5600 Automated hematocrit instrument. (a) Identification. An automated hematocrit instrument is a...

  11. 21 CFR 864.5600 - Automated hematocrit instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... measures the packed red cell volume of a blood sample to distinguish normal from abnormal states, such as anemia and erythrocytosis (an increase in the number of red cells). (b) Classification. Class II... § 864.5600 Automated hematocrit instrument. (a) Identification. An automated hematocrit instrument is a...

  12. Developing and utilizing an Euler computational method for predicting the airframe/propulsion effects for an aft-mounted turboprop transport. Volume 1: Theory document

    NASA Technical Reports Server (NTRS)

    Chen, H. C.; Yu, N. Y.

    1991-01-01

    An Euler flow solver was developed for predicting the airframe/propulsion integration effects for an aft-mounted turboprop transport. This solver employs a highly efficient multigrid scheme, with a successive mesh-refinement procedure to accelerate the convergence of the solution. A new dissipation model was also implemented to render solutions that are grid insensitive. The propeller power effects are simulated by the actuator disk concept. An embedded flow solution method was developed for predicting the detailed flow characteristics in the local vicinity of an aft-mounted propfan engine in the presence of a flow field induced by a complete aircraft. Results from test case analysis are presented. A user's guide for execution of computer programs, including format of various input files, sample job decks, and sample input files, is provided in an accompanying volume.

  13. Solid state electro-optic color filter and iris

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The electro-optic properties of lanthanum-modified lead zirconate titanate (PLZT) ferroelectric ceramic material are evaluated when utilized as a variable density and/or spectral filter in conjunction with a television scanning system. Emphasis was placed on the development of techniques and procedures for processing the PLZT disks and for applying efficient electrode structures. A number of samples were processed using different combinations of cleaning, electrode material, and deposition process. Best overall performance resulted from the direct evaporation of gold over chrome electrodes. A ruggedized mounting holder assembly was designed, fabricated, and tested. The assembly provides electrical contacts, high voltage protection, and support for the fragile PLZT disk, and permits mounting and optical alignment of the associated polarizers. Operational measurements of a PLZT sample mounted in the holder assembly were performed in conjunction with a television camera and the associated drive circuits. The data verified achievement of the elimination of the observed white-line effect.

  14. Sample Holder for Cryogenic Adhesive Shear Test

    NASA Technical Reports Server (NTRS)

    Ledbetter, F. E.; Clemons, J. M.; White, W. T.; Penn, B.; Semmel, M. L.

    1983-01-01

    Five samples tested in one cooldown. Holder mounted in testing machine. Submerged in cryogenic liquid held in cryostat. Movable crosshead of testing machine moves gradually downward. Samples placed under tension, one after another, starting with top one; each sample fails in turn before next is stressed.

  15. Mars Science Laboratory Sample Acquisition, Sample Processing and Handling Subsystem: A Description of the Sampling Functionality

    NASA Astrophysics Data System (ADS)

    Jandura, L.; Burke, K.; Kennedy, B.; Melko, J.; Okon, A.; Sunshine, D.

    2009-12-01

    The Sample Acquisition/Sample Processing and Handling (SA/SPaH) subsystem for the Mars Science Library (MSL) is a rover-based sampling system scheduled to launch in 2011. The SA/SPaH consists of a powdering drill and a scooping, sieving, and portioning device mounted on a turret at the end of a robotic arm. Also on the turret is a dust removal tool for clearing the surface of scientific targets, and two science instruments mounted on vibration isolators. The SA/SPaH can acquire powder from rocks at depths of 20 to 50 mm and can also pick up loose regolith with its scoop. The acquired sample is sieved and portioned and delivered to one of two instruments inside the rover for analysis. The functionality of the system will be described along with the targets the system can acquire and the sample that can be delivered. Top View of the SA/SPaH on the Rover

  16. Unattended reaction monitoring using an automated microfluidic sampler and on-line liquid chromatography.

    PubMed

    Patel, Darshan C; Lyu, Yaqi Fara; Gandarilla, Jorge; Doherty, Steve

    2018-04-03

    In-process sampling and analysis is an important aspect of monitoring kinetic profiles and impurity formation or rejection, both in development and during commercial manufacturing. In pharmaceutical process development, the technology of choice for a substantial portion of this analysis is high-performance liquid chromatography (HPLC). Traditionally, the sample extraction and preparation for reaction characterization have been performed manually. This can be time consuming, laborious, and impractical for long processes. Depending on the complexity of the sample preparation, there can be variability introduced by different analysts, and in some cases, the integrity of the sample can be compromised during handling. While there are commercial instruments available for on-line monitoring with HPLC, they lack capabilities in many key areas. Some do not provide integration of the sampling and analysis, while others afford limited flexibility in sample preparation. The current offerings provide a limited number of unit operations available for sample processing and no option for workflow customizability. This work describes development of a microfluidic automated program (MAP) which fully automates the sample extraction, manipulation, and on-line LC analysis. The flexible system is controlled using an intuitive Microsoft Excel based user interface. The autonomous system is capable of unattended reaction monitoring that allows flexible unit operations and workflow customization to enable complex operations and on-line sample preparation. The automated system is shown to offer advantages over manual approaches in key areas while providing consistent and reproducible in-process data. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Non-Contact Conductivity Measurement for Automated Sample Processing Systems

    NASA Technical Reports Server (NTRS)

    Beegle, Luther W.; Kirby, James P.

    2012-01-01

    A new method has been developed for monitoring and control of automated sample processing and preparation especially focusing on desalting of samples before analytical analysis (described in more detail in Automated Desalting Apparatus, (NPO-45428), NASA Tech Briefs, Vol. 34, No. 8 (August 2010), page 44). The use of non-contact conductivity probes, one at the inlet and one at the outlet of the solid phase sample preparation media, allows monitoring of the process, and acts as a trigger for the start of the next step in the sequence (see figure). At each step of the muti-step process, the system is flushed with low-conductivity water, which sets the system back to an overall low-conductivity state. This measurement then triggers the next stage of sample processing protocols, and greatly minimizes use of consumables. In the case of amino acid sample preparation for desalting, the conductivity measurement will define three key conditions for the sample preparation process. First, when the system is neutralized (low conductivity, by washing with excess de-ionized water); second, when the system is acidified, by washing with a strong acid (high conductivity); and third, when the system is at a basic condition of high pH (high conductivity). Taken together, this non-contact conductivity measurement for monitoring sample preparation will not only facilitate automation of the sample preparation and processing, but will also act as a way to optimize the operational time and use of consumables

  18. Automated grain mapping using wide angle convergent beam electron diffraction in transmission electron microscope for nanomaterials.

    PubMed

    Kumar, Vineet

    2011-12-01

    The grain size statistics, commonly derived from the grain map of a material sample, are important microstructure characteristics that greatly influence its properties. The grain map for nanomaterials is usually obtained manually by visual inspection of the transmission electron microscope (TEM) micrographs because automated methods do not perform satisfactorily. While the visual inspection method provides reliable results, it is a labor intensive process and is often prone to human errors. In this article, an automated grain mapping method is developed using TEM diffraction patterns. The presented method uses wide angle convergent beam diffraction in the TEM. The automated technique was applied on a platinum thin film sample to obtain the grain map and subsequently derive grain size statistics from it. The grain size statistics obtained with the automated method were found in good agreement with the visual inspection method.

  19. Adjustable mounting device for high-volume production of beam-shaping systems for high-power diode lasers

    NASA Astrophysics Data System (ADS)

    Haag, Sebastian; Bernhardt, Henning; Rübenach, Olaf; Haverkamp, Tobias; Müller, Tobias; Zontar, Daniel; Brecher, Christian

    2015-02-01

    In many applications for high-power diode lasers, the production of beam-shaping and homogenizing optical systems experience rising volumes and dynamical market demands. The automation of assembly processes on flexible and reconfigurable machines can contribute to a more responsive and scalable production. The paper presents a flexible mounting device designed for the challenging assembly of side-tab based optical systems. It provides design elements for precisely referencing and fixating two optical elements in a well-defined geometric relation. Side tabs are presented to the machine allowing the application of glue and a rotating mechanism allows the attachment to the optical elements. The device can be adjusted to fit different form factors and it can be used in high-volume assembly machines. The paper shows the utilization of the device for a collimation module consisting of a fast-axis and a slow-axis collimation lens. Results regarding the repeatability and process capability of bonding side tab assemblies as well as estimates from 3D simulation for overall performance indicators achieved such as cycle time and throughput will be discussed.

  20. Parallel Adjective High-Order CFD Simulations Characterizing SOFIA Cavity Acoustics

    NASA Technical Reports Server (NTRS)

    Barad, Michael F.; Brehm, Christoph; Kiris, Cetin C.; Biswas, Rupak

    2016-01-01

    This paper presents large-scale MPI-parallel computational uid dynamics simulations for the Stratospheric Observatory for Infrared Astronomy (SOFIA). SOFIA is an airborne, 2.5-meter infrared telescope mounted in an open cavity in the aft fuselage of a Boeing 747SP. These simulations focus on how the unsteady ow eld inside and over the cavity interferes with the optical path and mounting structure of the telescope. A temporally fourth-order accurate Runge-Kutta, and spatially fth-order accurate WENO- 5Z scheme was used to perform implicit large eddy simulations. An immersed boundary method provides automated gridding for complex geometries and natural coupling to a block-structured Cartesian adaptive mesh re nement framework. Strong scaling studies using NASA's Pleiades supercomputer with up to 32k CPU cores and 4 billion compu- tational cells shows excellent scaling. Dynamic load balancing based on execution time on individual AMR blocks addresses irregular numerical cost associated with blocks con- taining boundaries. Limits to scaling beyond 32k cores are identi ed, and targeted code optimizations are discussed.

  1. Parallel Adaptive High-Order CFD Simulations Characterizing SOFIA Cavitiy Acoustics

    NASA Technical Reports Server (NTRS)

    Barad, Michael F.; Brehm, Christoph; Kiris, Cetin C.; Biswas, Rupak

    2015-01-01

    This paper presents large-scale MPI-parallel computational uid dynamics simulations for the Stratospheric Observatory for Infrared Astronomy (SOFIA). SOFIA is an airborne, 2.5-meter infrared telescope mounted in an open cavity in the aft fuselage of a Boeing 747SP. These simulations focus on how the unsteady ow eld inside and over the cavity interferes with the optical path and mounting structure of the telescope. A tempo- rally fourth-order accurate Runge-Kutta, and a spatially fth-order accurate WENO-5Z scheme were used to perform implicit large eddy simulations. An immersed boundary method provides automated gridding for complex geometries and natural coupling to a block-structured Cartesian adaptive mesh re nement framework. Strong scaling studies using NASA's Pleiades supercomputer with up to 32k CPU cores and 4 billion compu- tational cells shows excellent scaling. Dynamic load balancing based on execution time on individual AMR blocks addresses irregular numerical cost associated with blocks con- taining boundaries. Limits to scaling beyond 32k cores are identi ed, and targeted code optimizations are discussed.

  2. WATER TREATMENT

    DOEpatents

    Pitman, R.W.; Conley, W.R. Jr.

    1962-12-01

    An automated system for adding clarifying chemicals to water in a water treatment plant is described. To a sample of the floc suspension polyacrylamide or similar filter aid chemicals are added, and the sample is then put through a fast filter. The resulting filtrate has the requisite properties for monitoring in an optical turbidimeter to control the automated system. (AEC)

  3. Applications of Text Analysis Tools for Spoken Response Grading

    ERIC Educational Resources Information Center

    Crossley, Scott; McNamara, Danielle

    2013-01-01

    This study explores the potential for automated indices related to speech delivery, language use, and topic development to model human judgments of TOEFL speaking proficiency in second language (L2) speech samples. For this study, 244 transcribed TOEFL speech samples taken from 244 L2 learners were analyzed using automated indices taken from…

  4. Proceedings of the Annual DARPA/AFGL Seismic Research Symposium (10th) Held in Fallbrook, California on May 3-5, 1988. Addendum

    DTIC Science & Technology

    1990-12-17

    were measured with LVDT’s mounted on rings encircling the sample. Axial force was generated from an amplified D/A sinusoidal voltage and up to 1000...19 inch rack mount or stand-alone, 7.0 inches high 10 Mbit Ethernet With on-board Transceiver 1.5 Mb/Sec Asynchronous SCSI Bus UNIX and C right to...use license HA RD WARE 4 or 12 MByte Expansion Memory Boards Monochrome or Color Video, Monitor, Keyboard, and Mouse 19-inch Rack- Mount Removable Disk

  5. Water-level and wave measurements in the Chandeleur Islands, Louisiana, 2012 and 2013

    USGS Publications Warehouse

    Dickhudt, Patrick J.; Sherwood, Christopher R.; DeWitt, Nancy T.

    2015-01-01

    This report documents measurements of atmospheric pressure, water levels, and waves made by the U.S. Geological Survey in the Chandeleur Islands, Louisiana, during 2012 and 2013 as part of the Barrier Island Evolution Research project. Simple, inexpensive pressure sensors mounted in shallow wells were buried in the beach and left for one hurricane season and one winter-storm season. Gauges with rapid-sampling pressure sensors that provided nondirectional wave data and water-level data were mounted on rugged mounts on the Chandeleur Sound side and at the base of a tower at the northern end of the island chain. Additionally, an atmospheric pressure sensor was mounted on the tower to provide a local atmospheric pressure measurement for correcting the submerged pressure records.

  6. Characterization of organic contaminants in environmental samples associated with mount St. Helens 1980 volcanic eruption

    USGS Publications Warehouse

    Pereira, W.E.

    1982-01-01

    Volcanic ash, surface-water, and bottom-material samples obtained in the vicinity of Mount St. Helens after the May 18, 1980, eruption were analyzed for organic contaminants by using capillary gas chromatography-mass spectrometry-computer techniques. Classes of compounds identified include n-alkanes, fatty acids, dicarboxylic acids, aromatic acids and aldehydes, phenols, resin acids, terpenes, and insect juvenile hormones. The most probable source of these compounds is from pyrolysis of plant and soil organic matter during and after the eruption. The toxicity of selected compounds and their environmental significance are discussed.

  7. First evaluation of automated specimen inoculation for wound swab samples by use of the Previ Isola system compared to manual inoculation in a routine laboratory: finding a cost-effective and accurate approach.

    PubMed

    Mischnik, Alexander; Mieth, Markus; Busch, Cornelius J; Hofer, Stefan; Zimmermann, Stefan

    2012-08-01

    Automation of plate streaking is ongoing in clinical microbiological laboratories, but evaluation for routine use is mostly open. In the present study, the recovery of microorganisms from the Previ Isola system plated polyurethane (PU) swab samples is compared to manually plated control viscose swab samples from wounds according to the CLSI procedure M40-A (quality control of microbiological transport systems). One hundred twelve paired samples (224 swabs) were analyzed. In 80/112 samples (71%), concordant culture results were obtained with the two methods. In 32/112 samples (29%), CFU recovery of microorganisms from the two methods was discordant. In 24 (75%) of the 32 paired samples with a discordant result, Previ Isola plated PU swabs were superior. In 8 (25%) of the 32 paired samples with a discordant result, control viscose swabs were superior. The quality of colony growth on culture media for further investigations was superior with Previ Isola inoculated plates compared to manual plating techniques. Gram stain results were concordant between the two methods in 62/112 samples (55%). In 50/112 samples (45%), the results of Gram staining were discordant between the two methods. In 34 (68%) of the 50 paired samples with discordant results, Gram staining of PU swabs was superior to that of control viscose swabs. In 16 (32%) of the 50 paired samples, Gram staining of control viscose swabs was superior to that of PU swabs. We report the first clinical evaluation of Previ Isola automated specimen inoculation for wound swab samples. This study suggests that use of an automated specimen inoculation system has good results with regard to CFU recovery, quality of Gram staining, and accuracy of diagnosis.

  8. First Evaluation of Automated Specimen Inoculation for Wound Swab Samples by Use of the Previ Isola System Compared to Manual Inoculation in a Routine Laboratory: Finding a Cost-Effective and Accurate Approach

    PubMed Central

    Mieth, Markus; Busch, Cornelius J.; Hofer, Stefan; Zimmermann, Stefan

    2012-01-01

    Automation of plate streaking is ongoing in clinical microbiological laboratories, but evaluation for routine use is mostly open. In the present study, the recovery of microorganisms from the Previ Isola system plated polyurethane (PU) swab samples is compared to manually plated control viscose swab samples from wounds according to the CLSI procedure M40-A (quality control of microbiological transport systems). One hundred twelve paired samples (224 swabs) were analyzed. In 80/112 samples (71%), concordant culture results were obtained with the two methods. In 32/112 samples (29%), CFU recovery of microorganisms from the two methods was discordant. In 24 (75%) of the 32 paired samples with a discordant result, Previ Isola plated PU swabs were superior. In 8 (25%) of the 32 paired samples with a discordant result, control viscose swabs were superior. The quality of colony growth on culture media for further investigations was superior with Previ Isola inoculated plates compared to manual plating techniques. Gram stain results were concordant between the two methods in 62/112 samples (55%). In 50/112 samples (45%), the results of Gram staining were discordant between the two methods. In 34 (68%) of the 50 paired samples with discordant results, Gram staining of PU swabs was superior to that of control viscose swabs. In 16 (32%) of the 50 paired samples, Gram staining of control viscose swabs was superior to that of PU swabs. We report the first clinical evaluation of Previ Isola automated specimen inoculation for wound swab samples. This study suggests that use of an automated specimen inoculation system has good results with regard to CFU recovery, quality of Gram staining, and accuracy of diagnosis. PMID:22692745

  9. Automated Liquid Microjunction Surface Sampling-HPLC-MS/MS Analysis of Drugs and Metabolites in Whole-Body Thin Tissue Sections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kertesz, Vilmos; Van Berkel, Gary J

    A fully automated liquid extraction-based surface sampling system utilizing a commercially available autosampler coupled to high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) detection is reported. Discrete spots selected for droplet-based sampling and automated sample queue generation for both the autosampler and MS were enabled by using in-house developed software. In addition, co-registration of spatially resolved sampling position and HPLC-MS information to generate heatmaps of compounds monitored for subsequent data analysis was also available in the software. The system was evaluated with whole-body thin tissue sections from propranolol dosed rat. The hands-free operation of the system was demonstrated by creating heatmapsmore » of the parent drug and its hydroxypropranolol glucuronide metabolites with 1 mm resolution in the areas of interest. The sample throughput was approximately 5 min/sample defined by the time needed for chromatographic separation. The spatial distributions of both the drug and its metabolites were consistent with previous studies employing other liquid extraction-based surface sampling methodologies.« less

  10. High-temperature strain cell for tomographic imaging

    DOEpatents

    MacDowell, Alastair A.; Nasiatka, James; Haboub, Abdel; Ritchie, Robert O.; Bale, Hrishikesh A.

    2015-06-16

    This disclosure provides systems, methods, and apparatus related to the high temperature mechanical testing of materials. In one aspect, a method includes providing an apparatus. The apparatus may include a chamber. The chamber may comprise a top portion and a bottom portion, with the top portion and the bottom portion each joined to a window material. A first cooled fixture and a second cooled fixture may be mounted to the chamber and configured to hold the sample in the chamber. A plurality of heating lamps may be mounted to the chamber and positioned to heat the sample. The sample may be placed in the first and the second cooled fixtures. The sample may be heated to a specific temperature using the heating lamps. Radiation may be directed though the window material, the radiation thereafter interacting with the sample and exiting the chamber through the window material.

  11. SEM technique for imaging and measuring electronic transport in nanocomposites based on electric field induced contrast

    DOEpatents

    Jesse, Stephen [Knoxville, TN; Geohegan, David B [Knoxville, TN; Guillorn, Michael [Brooktondale, NY

    2009-02-17

    Methods and apparatus are described for SEM imaging and measuring electronic transport in nanocomposites based on electric field induced contrast. A method includes mounting a sample onto a sample holder, the sample including a sample material; wire bonding leads from the sample holder onto the sample; placing the sample holder in a vacuum chamber of a scanning electron microscope; connecting leads from the sample holder to a power source located outside the vacuum chamber; controlling secondary electron emission from the sample by applying a predetermined voltage to the sample through the leads; and generating an image of the secondary electron emission from the sample. An apparatus includes a sample holder for a scanning electron microscope having an electrical interconnect and leads on top of the sample holder electrically connected to the electrical interconnect; a power source and a controller connected to the electrical interconnect for applying voltage to the sample holder to control the secondary electron emission from a sample mounted on the sample holder; and a computer coupled to a secondary electron detector to generate images of the secondary electron emission from the sample.

  12. Modular high power diode lasers with flexible 3D multiplexing arrangement optimized for automated manufacturing

    NASA Astrophysics Data System (ADS)

    Könning, Tobias; Bayer, Andreas; Plappert, Nora; Faßbender, Wilhelm; Dürsch, Sascha; Küster, Matthias; Hubrich, Ralf; Wolf, Paul; Köhler, Bernd; Biesenbach, Jens

    2018-02-01

    A novel 3-dimensional arrangement of mirrors is used to re-arrange beams from 1-D and 2-D high power diode laser arrays. The approach allows for a variety of stacking geometries, depending on individual requirements. While basic building blocks, including collimating optics, always remain the same, most adaptations can be realized by simple rearrangement of a few optical components. Due to fully automated alignment processes, the required changes can be realized in software by changing coordinates, rather than requiring customized mechanical components. This approach minimizes development costs due to its flexibility, while reducing overall product cost by using similar building blocks for a variety of products and utilizing a high grade of automation. The modules can be operated with industrial grade water, lowering overall system and maintenance cost. Stackable macro coolers are used as the smallest building block of the system. Each cooler can hold up to five diode laser bars. Micro optical components, collimating the beam, are mounted directly to the cooler. All optical assembly steps are fully automated. Initially, the beams from all laser bars propagate in the same direction. Key to the concept is an arrangement of deflectors, which re-arrange the beams into a 2-D array of the desired shape and high fill factor. Standard multiplexing techniques like polarization- or wavelengths-multiplexing have been implemented as well. A variety of fiber coupled modules ranging from a few hundred watts of optical output power to multiple kilowatts of power, as well as customized laser spot geometries like uniform line sources, have been realized.

  13. First On-Site Data Analysis System for Subaru/Suprime-Cam

    NASA Astrophysics Data System (ADS)

    Furusawa, Hisanori; Okura, Yuki; Mineo, Sogo; Takata, Tadafumi; Nakata, Fumiaki; Tanaka, Manobu; Katayama, Nobuhiko; Itoh, Ryosuke; Yasuda, Naoki; Miyazaki, Satoshi; Komiyama, Yutaka; Utsumi, Yousuke; Uchida, Tomohisa; Aihara, Hiroaki

    2011-03-01

    We developed an automated on-site quick analysis system for mosaic CCD data of Suprime-Cam, which is a wide-field camera mounted at the prime focus of the Subaru Telescope, Mauna Kea, Hawaii. The first version of the data-analysis system was constructed, and started to operate in general observations. This system is a new function of observing support at the Subaru Telescope to provide the Subaru user community with an automated on-site data evaluation, aiming at improvements of observers' productivity, especially in large imaging surveys. The new system assists the data evaluation tasks in observations by the continuous monitoring of the characteristics of every data frame during observations. The evaluation results and data frames processed by this system are also useful for reducing the data-processing time in a full analysis after an observation. The primary analysis functions implemented in the data-analysis system are composed of automated realtime analysis for data evaluation and on-demand analysis, which is executed upon request, including mosaicing analysis and flat making analysis. In data evaluation, which is controlled by the organizing software, the database keeps track of the analysis histories, as well as the evaluated values of data frames, including seeing and sky background levels; it also helps in the selection of frames for mosaicing and flat making analysis. We examined the system performance and confirmed an improvement in the data-processing time by a factor of 9 with the aid of distributed parallel data processing and on-memory data processing, which makes the automated data evaluation effective.

  14. Wafer-level radiometric performance testing of uncooled microbolometer arrays

    NASA Astrophysics Data System (ADS)

    Dufour, Denis G.; Topart, Patrice; Tremblay, Bruno; Julien, Christian; Martin, Louis; Vachon, Carl

    2014-03-01

    A turn-key semi-automated test system was constructed to perform on-wafer testing of microbolometer arrays. The system allows for testing of several performance characteristics of ROIC-fabricated microbolometer arrays including NETD, SiTF, ROIC functionality, noise and matrix operability, both before and after microbolometer fabrication. The system accepts wafers up to 8 inches in diameter and performs automated wafer die mapping using a microscope camera. Once wafer mapping is completed, a custom-designed quick insertion 8-12 μm AR-coated Germanium viewport is placed and the chamber is pumped down to below 10-5 Torr, allowing for the evaluation of package-level focal plane array (FPA) performance. The probe card is electrically connected to an INO IRXCAM camera core, a versatile system that can be adapted to many types of ROICs using custom-built interface printed circuit boards (PCBs). We currently have the capability for testing 384x288, 35 μm pixel size and 160x120, 52 μm pixel size FPAs. For accurate NETD measurements, the system is designed to provide an F/1 view of two rail-mounted blackbodies seen through the Germanium window by the die under test. A master control computer automates the alignment of the probe card to the dies, the positioning of the blackbodies, FPA image frame acquisition using IRXCAM, as well as data analysis and storage. Radiometric measurement precision has been validated by packaging dies measured by the automated probing system and re-measuring the SiTF and Noise using INO's pre-existing benchtop system.

  15. Automating mouse weighing in group homecages with Raspberry Pi micro-computers.

    PubMed

    Noorshams, Omid; Boyd, Jamie D; Murphy, Timothy H

    2017-06-15

    Operant training systems make use of water or food restriction and make it necessary to weigh animals to ensure compliance with experimental endpoints. In other applications periodic weighing is necessary to assess drug side-effects, or as an endpoint in feeding experiments. Periodic weighing while essential can disrupt animal circadian rhythms and social structure. Automatic weighing system within paired mouse homecages. Up to 10 mice freely move between two cages (28×18×9cm) which were connected by a weighing chamber mounted on a load cell. Each mouse was identified using an RFID tag placed under the skin of the neck. A single-board computer (Raspberry Pi; RPi) controls the task, logging RFID tag, load cell weights, and time stamps from each RFID detection until the animal leaves the chamber. Collected data were statistically analyzed to estimate mouse weights. We anticipate integration with tasks where automated imaging or behaviour is assessed in homecages. Mice frequently move between the two cages, an average of 42+-16 times/day/mouse at which time we obtained weights. We report accurate determination of mouse weight and long term monitoring over 53days. Comparison with existing methods Although commercial systems are available for automatically weighing rodents, they only work with single animals, or are not open source nor cost effective for specific custom application. This automated system permits automated weighing of mice ∼40 times per day. The system employs inexpensive hardware and open-source Python code. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. DEdicated MONitor of EXotransits and Transients (DEMONEXT): a low-cost robotic and automated telescope for followup of exoplanetary transits and other transient events

    NASA Astrophysics Data System (ADS)

    Villanueva, S.; Eastman, J. D.; Gaudi, B. S.; Pogge, R. W.; Stassun, K. G.; Trueblood, M.; Trueblood, P.

    2016-07-01

    We present the design and development of the DEdicatedMONitor of EXotransits and Transients (DEMONEXT), an automated and robotic 20 inch telescope jointly funded by The Ohio State University and Vanderbilt University. The telescope is a PlaneWave CDK20 f/6.8 Corrected Dall-Kirkham Astrograph telescope on a Mathis Instruments MI-750/1000 Fork Mount located atWiner Observatory in Sonoita, AZ. DEMONEXT has a Hedrick electronic focuser, Finger Lakes Instrumentation (FLI) CFW-3-10 filter wheel, and a 2048 x 2048 pixel FLI Proline CCD3041 camera with a pixel scale of 0.90 arc-seconds per pixel and a 30.7× 30.7 arc-minute field-of-view. The telescope's automation, controls, and scheduling are implemented in Python, including a facility to add new targets in real time for rapid follow-up of time-critical targets. DEMONEXT will be used for the confirmation and detailed investigation of newly discovered planet candidates from the Kilodegree Extremely Little Telescope (KELT) survey, exploration of the atmospheres of Hot Jupiters via transmission spectroscopy and thermal emission measurements, and monitoring of select eclipsing binary star systems as benchmarks for models of stellar evolution. DEMONEXT will enable rapid confirmation imaging of supernovae, flare stars, tidal disruption events, and other transients discovered by the All Sky Automated Survey for SuperNovae (ASAS-SN). DEMONEXT will also provide follow-up observations of single-transit planets identified by the Transiting Exoplanet Survey Satellite (TESS) mission, and to validate long-period eclipsing systems discovered by Gaia.

  17. Impact of collection container material and holding times on sample integrity for mercury and methylmercury in water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riscassi, Ami L; Miller, Carrie L; Brooks, Scott C

    Mercury (Hg) and methylmercury (MeHg) concentrations in streamwater can vary on short timescales (hourly or less) during storm flow and on a diel cycle; the frequency and timing of sampling required to accurately characterize these dynamics may be difficult to accomplish manually. Automated sampling can assist in sample collection; however use has been limited for Hg and MeHg analysis due to stability concerns of trace concentrations during extended storage times. We examined the viability of using automated samplers with disposable low-density polyethylene (LDPE) sample bags to collect industrially contaminated streamwater for unfiltered and filtered Hg and MeHg analysis. Specifically wemore » investigated the effect of holding times ranging from hours to days on streamwater collected during baseflow and storm flow. Unfiltered and filtered Hg and MeHg concentrations decreased with increases in time prior to sample processing; holding times of 24 hours or less resulted in concentration changes (mean 11 7% different) similar to variability in duplicates collected manually during analogous field conditions (mean 7 10% different). Comparisons of samples collected with manual and automated techniques throughout a year for a wide range of stream conditions were also found to be similar to differences observed between duplicate grab samples. These results demonstrate automated sampling into LDPE bags with holding times of 24 hours or less can be effectively used to collect streamwater for Hg and MeHg analysis, and encourage the testing of these materials and methods for implementation in other aqueous systems where high-frequency sampling is warranted.« less

  18. Using hydrogels in microscopy: A tutorial.

    PubMed

    Flood, Peter; Page, Henry; Reynaud, Emmanuel G

    2016-05-01

    Sample preparation for microscopy is a crucial step to ensure the best experimental outcome. It often requires the use of specific mounting media that have to be tailored to not just the sample but the chosen microscopy technique. The media must not damage the sample or impair the optical path, and may also have to support the correct physiological function/development of the sample. For decades, researchers have used embedding media such as hydrogels to maintain samples in place. Their ease of use and transparency has promoted them as mainstream mounting media. However, they are not as straightforward to implement as assumed. They can contain contaminants, generate forces on the sample, have complex diffusion and structural properties that are influenced by multiple factors and are generally not designed for microscopy in mind. This short review will discuss the advantages and disadvantages of using hydrogels for microscopy sample preparation and highlight some of the less obvious problems associated with the area. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Development and evaluation of a water level proportional water sampler

    NASA Astrophysics Data System (ADS)

    Schneider, P.; Lange, A.; Doppler, T.

    2013-12-01

    We developed and adapted a new type of sampler for time-integrated, water level proportional water quality sampling (e.g. nutrients, contaminants and stable isotopes). Our samplers are designed for sampling small to mid-size streams based on the law of Hagen-Poiseuille, where a capillary (or a valve) limits the sampling aliquot by reducing the air flux out of a submersed plastic (HDPE) sampling container. They are good alternatives to battery-operated automated water samplers when working in remote areas, or at streams that are characterized by pronounced daily discharge variations such as glacier streams. We evaluated our samplers against standard automated water samplers (ISCO 2900 and ISCO 6712) during the snowmelt in the Black Forest and the Alps and tested them in remote glacial catchments in Iceland, Switzerland and Kyrgyzstan. The results clearly showed that our samplers are an adequate tool for time-integrated, water level proportional water sampling at remote test sites, as they do not need batteries, are relatively inexpensive, lightweight, and compact. They are well suited for headwater streams - especially when sampling for stable isotopes - as the sampled water is perfectly protected against evaporation. Moreover, our samplers have a reduced risk of icing in cold environments, as they are installed submersed in water, whereas automated samplers (typically installed outside the stream) may get clogged due to icing of hoses. Based on this study, we find these samplers to be an adequate replacement for automated samplers when time-integrated sampling or solute load estimates are the main monitoring tasks.

  20. An update: improvements in imaging perfluorocarbon-mounted plant leaves with implications for studies of plant pathology, physiology, development and cell biology

    PubMed Central

    Littlejohn, George R.; Mansfield, Jessica C.; Christmas, Jacqueline T.; Witterick, Eleanor; Fricker, Mark D.; Grant, Murray R.; Smirnoff, Nicholas; Everson, Richard M.; Moger, Julian; Love, John

    2014-01-01

    Plant leaves are optically complex, which makes them difficult to image by light microscopy. Careful sample preparation is therefore required to enable researchers to maximize the information gained from advances in fluorescent protein labeling, cell dyes and innovations in microscope technologies and techniques. We have previously shown that mounting leaves in the non-toxic, non-fluorescent perfluorocarbon (PFC), perfluorodecalin (PFD) enhances the optical properties of the leaf with minimal impact on physiology. Here, we assess the use of the PFCs, PFD, and perfluoroperhydrophenanthrene (PP11) for in vivo plant leaf imaging using four advanced modes of microscopy: laser scanning confocal microscopy (LSCM), two-photon fluorescence microscopy, second harmonic generation microscopy, and stimulated Raman scattering (SRS) microscopy. For every mode of imaging tested, we observed an improved signal when leaves were mounted in PFD or in PP11, compared to mounting the samples in water. Using an image analysis technique based on autocorrelation to quantitatively assess LSCM image deterioration with depth, we show that PP11 outperformed PFD as a mounting medium by enabling the acquisition of clearer images deeper into the tissue. In addition, we show that SRS microscopy can be used to image PFCs directly in the mesophyll and thereby easily delimit the “negative space” within a leaf, which may have important implications for studies of leaf development. Direct comparison of on and off resonance SRS micrographs show that PFCs do not to form intracellular aggregates in live plants. We conclude that the application of PFCs as mounting media substantially increases advanced microscopy image quality of living mesophyll and leaf vascular bundle cells. PMID:24795734

  1. A recommended procedure for the preparation of oriented clay-mineral specimens for X-ray diffraction analysis; modifications to Drever's filter-membrane peel technique

    USGS Publications Warehouse

    Pollastro, R.M.

    1982-01-01

    Extremely well-oriented clay mineral mounts for X-ray diffraction analysis can be prepared quickly and without introducing segregation using the filter-membrane peel technique. Mounting problems encountered with smectite-rich samples can be resolved by using minimal sample and partial air-drying of the clay film before transfer to a glass slide. Samples containing small quantities of clay can produce useful oriented specimens if Teflon masks having more restrictive areas are inserted above the membrane filter during clay deposition. War]page and thermal shock of glass slides can be controlled by using a flat, porous, ceramic plate as a holding surface during heat treatments.

  2. Principal component analysis and analysis of variance on the effects of Entellan New on the Raman spectra of fibers.

    PubMed

    Yu, Marcia M L; Sandercock, P Mark L

    2012-01-01

    During the forensic examination of textile fibers, fibers are usually mounted on glass slides for visual inspection and identification under the microscope. One method that has the capability to accurately identify single textile fibers without subsequent demounting is Raman microspectroscopy. The effect of the mountant Entellan New on the Raman spectra of fibers was investigated to determine if it is suitable for fiber analysis. Raman spectra of synthetic fibers mounted in three different ways were collected and subjected to multivariate analysis. Principal component analysis score plots revealed that while spectra from different fiber classes formed distinct groups, fibers of the same class formed a single group regardless of the mounting method. The spectra of bare fibers and those mounted in Entellan New were found to be statistically indistinguishable by analysis of variance calculations. These results demonstrate that fibers mounted in Entellan New may be identified directly by Raman microspectroscopy without further sample preparation. © 2011 American Academy of Forensic Sciences.

  3. An automated system for global atmospheric sampling using B-747 airliners

    NASA Technical Reports Server (NTRS)

    Lew, K. Q.; Gustafsson, U. R. C.; Johnson, R. E.

    1981-01-01

    The global air sampling program utilizes commercial aircrafts in scheduled service to measure atmospheric constituents. A fully automated system designed for the 747 aircraft is described. Airline operational constraints and data and control subsystems are treated. The overall program management, system monitoring, and data retrieval from four aircraft in global service is described.

  4. Radiation dosimeters

    DOEpatents

    Hoelsher, James W.; Hegland, Joel E.; Braunlich, Peter F.; Tetzlaff, Wolfgang

    1992-01-01

    Radiation dosimeters and dosimeter badges. The dosimeter badges include first and second parts which are connected to join using a securement to produce a sealed area in which at least one dosimeter is held and protected. The badge parts are separated to expose the dosimeters to a stimulating laser beam used to read dose exposure information therefrom. The badge is constructed to allow automated disassembly and reassembly in a uniquely fitting relationship. An electronic memory is included to provide calibration and identification information used during reading of the dosimeter. Dosimeter mounts which reduce thermal heating requirements are shown. Dosimeter constructions and production methods using thin substrates and phosphor binder-layers applied thereto are also taught.

  5. Method of converting an existing vehicle powertrain to a hybrid powertrain system

    DOEpatents

    Reed, Jr., Richard G.; Boberg, Evan S.; Lawrie, Robert E.; Castaing, Francois J.

    2001-12-25

    A method of converting an existing vehicle powertrain including a manual transmission to a hybrid powertrain system with an automated powertrain transmission. The first step in the method of attaching a gear train housing to a housing of said manual transmission, said gear train housing receiving as end of drive shaft of said transmission and rotatably supporting a gear train assembly. Secondly, mounting an electric motor/generator to said gear train housing and attaching a motor/generator drive shaft of said electric motor/generator to said gear train assembly. Lastly, connecting an electro-mechanical clutch actuator to a friction clutch mechanism of said manual transmission.

  6. Autonomous Dome for a Robotic Telescope

    NASA Astrophysics Data System (ADS)

    Kumar, A.; Sengupta, A.; Ganesh, S.

    2016-12-01

    The Physical Research Laboratory operates a 50 cm robotic observatory at Mount Abu (Rajsthan, India). This Automated Telescope for Variability Studies (ATVS) makes use of the Remote Telescope System 2 (RTS2) for autonomous operations. The observatory uses a 3.5 m dome from Sirius Observatories. We have developed electronics using Arduino electronic circuit boards with home grown logic and software to control the dome operations. We are in the process of completing the drivers to link our Arduino based dome controller with RTS2. This document is a short description of the various phases of the development and their integration to achieve the required objective.

  7. Development of a Miniature Mass Spectrometer and an Automated Detector for Sampling Explosive Materials

    PubMed Central

    Hashimoto, Yuichiro

    2017-01-01

    The development of a robust ionization source using the counter-flow APCI, miniature mass spectrometer, and an automated sampling system for detecting explosives are described. These development efforts using mass spectrometry were made in order to improve the efficiencies of on-site detection in areas such as security, environmental, and industrial applications. A development team, including the author, has struggled for nearly 20 years to enhance the robustness and reduce the size of mass spectrometers to meet the requirements needed for on-site applications. This article focuses on the recent results related to the detection of explosive materials where automated particle sampling using a cyclone concentrator permitted the inspection time to be successfully reduced to 3 s. PMID:28337396

  8. Comparison of different methods to quantify fat classes in bakery products.

    PubMed

    Shin, Jae-Min; Hwang, Young-Ok; Tu, Ock-Ju; Jo, Han-Bin; Kim, Jung-Hun; Chae, Young-Zoo; Rhu, Kyung-Hun; Park, Seung-Kook

    2013-01-15

    The definition of fat differs in different countries; thus whether fat is listed on food labels depends on the country. Some countries list crude fat content in the 'Fat' section on the food label, whereas other countries list total fat. In this study, three methods were used for determining fat classes and content in bakery products: the Folch method, the automated Soxhlet method, and the AOAC 996.06 method. The results using these methods were compared. Fat (crude) extracted by the Folch and Soxhlet methods was gravimetrically determined and assessed by fat class using capillary gas chromatography (GC). In most samples, fat (total) content determined by the AOAC 996.06 method was lower than the fat (crude) content determined by the Folch or automated Soxhlet methods. Furthermore, monounsaturated fat or saturated fat content determined by the AOAC 996.06 method was lowest. Almost no difference was observed between fat (crude) content determined by the Folch method and that determined by the automated Soxhlet method for nearly all samples. In three samples (wheat biscuits, butter cookies-1, and chocolate chip cookies), monounsaturated fat, saturated fat, and trans fat content obtained by the automated Soxhlet method was higher than that obtained by the Folch method. The polyunsaturated fat content obtained by the automated Soxhlet method was not higher than that obtained by the Folch method in any sample. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. ABO Mistyping of cis-AB Blood Group by the Automated Microplate Technique.

    PubMed

    Chun, Sejong; Ryu, Mi Ra; Cha, Seung-Yeon; Seo, Ji-Young; Cho, Duck

    2018-01-01

    The cis -AB phenotype, although rare, is the relatively most frequent of ABO subgroups in Koreans. To prevent ABO mistyping of cis -AB samples, our hospital has applied a combination of the manual tile method with automated devices. Herein, we report cases of ABO mistyping detected by the combination testing system. Cases that showed discrepant results by automated devices and the manual tile method were evaluated. These samples were also tested by the standard tube method. The automated devices used in this study were a QWALYS-3 and Galileo NEO. Exons 6 and 7 of the ABO gene were sequenced. 13 cases that had the cis -AB allele showed results suggestive of the cis -AB subgroup by manual methods, but were interpreted as AB by either automated device. This happened in 87.5% of these cases by QWALYS-3 and 70.0% by Galileo NEO. Genotyping results showed that 12 cases were ABO*cis-AB01/ABO*O01 or ABO*cis-AB01/ABO*O02 , and one case was ABO*cis-AB01/ ABO*A102. Cis -AB samples were mistyped as AB by the automated microplate technique in some cases. We suggest that the manual tile method can be a simple supplemental test for the detection of the cis -AB phenotype, especially in countries with relatively high cis- AB prevalence.

  10. Automating Energy Bandgap Measurements in Semiconductors Using LabVIEW

    ERIC Educational Resources Information Center

    Garg, Amit; Sharma, Reena; Dhingra, Vishal

    2010-01-01

    In this paper, we report the development of an automated system for energy bandgap and resistivity measurement of a semiconductor sample using Four-Probe method for use in the undergraduate laboratory of Physics and Electronics students. The automated data acquisition and analysis system has been developed using National Instruments USB-6008 DAQ…

  11. Automated data collection based on RoboDiff at the ESRF beamline MASSIF-1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nurizzo, Didier, E-mail: Didier.nurizzo@esrf.fr; Guichard, Nicolas; McSweeney, Sean

    2016-07-27

    The European Synchrotron Radiation Facility has a long standing history in the automation of experiments in Macromolecular Crystallography. MASSIF-1 (Massively Automated Sample Screening and evaluation Integrated Facility), a beamline constructed as part of the ESRF Upgrade Phase I program, has been open to the external user community since July 2014 and offers a unique completely automated data collection service to both academic and industrial structural biologists.

  12. The LabTube - a novel microfluidic platform for assay automation in laboratory centrifuges.

    PubMed

    Kloke, A; Fiebach, A R; Zhang, S; Drechsel, L; Niekrawietz, S; Hoehl, M M; Kneusel, R; Panthel, K; Steigert, J; von Stetten, F; Zengerle, R; Paust, N

    2014-05-07

    Assay automation is the key for successful transformation of modern biotechnology into routine workflows. Yet, it requires considerable investment in processing devices and auxiliary infrastructure, which is not cost-efficient for laboratories with low or medium sample throughput or point-of-care testing. To close this gap, we present the LabTube platform, which is based on assay specific disposable cartridges for processing in laboratory centrifuges. LabTube cartridges comprise interfaces for sample loading and downstream applications and fluidic unit operations for release of prestored reagents, mixing, and solid phase extraction. Process control is achieved by a centrifugally-actuated ballpen mechanism. To demonstrate the workflow and functionality of the LabTube platform, we show two LabTube automated sample preparation assays from laboratory routines: DNA extractions from whole blood and purification of His-tagged proteins. Equal DNA and protein yields were observed compared to manual reference runs, while LabTube automation could significantly reduce the hands-on-time to one minute per extraction.

  13. Mechanical sieve for screening mineral samples

    NASA Technical Reports Server (NTRS)

    Otto, W. P.

    1970-01-01

    Mechanical sieve consists of three horizontal screens mounted in a vertical stack. A combination of rotation and tapping produces an even flow across the screens, dislodges trapped particles, an ensures rapid segregation of the sample.

  14. Diverse protocols for correlative super-resolution fluorescence imaging and electron microscopy of chemically fixed samples

    PubMed Central

    Kopek, Benjamin G.; Paez-Segala, Maria G.; Shtengel, Gleb; Sochacki, Kem A.; Sun, Mei G.; Wang, Yalin; Xu, C. Shan; van Engelenburg, Schuyler B.; Taraska, Justin W.; Looger, Loren L.; Hess, Harald F.

    2017-01-01

    Our groups have recently developed related approaches for sample preparation for super-resolution imaging within endogenous cellular environments using correlative light and electron microscopy (CLEM). Four distinct techniques for preparing and acquiring super-resolution CLEM datasets on aldehyde-fixed specimens are provided, including Tokuyasu cryosectioning, whole-cell mount, cell unroofing and platinum replication, and resin embedding and sectioning. Choice of the best protocol for a given application depends on a number of criteria that are discussed in detail. Tokuyasu cryosectioning is relatively rapid but is limited to small, delicate specimens. Whole-cell mount has the simplest sample preparation but is restricted to surface structures. Cell unroofing and platinum replica creates high-contrast, 3-dimensional images of the cytoplasmic surface of the plasma membrane, but is more challenging than whole-cell mount. Resin embedding permits serial sectioning of large samples, but is limited to osmium-resistant probes, and is technically difficult. Expected results from these protocols include super-resolution localization (~10–50 nm) of fluorescent targets within the context of electron microscopy ultrastructure, which can help address cell biological questions. These protocols can be completed in 2–7 days, are compatible with a number of super-resolution imaging protocols, and are broadly applicable across biology. PMID:28384138

  15. Vibration measurements of the Daniel K. Inouye Solar Telescope mount, Coudé rotator, and enclosure assemblies

    NASA Astrophysics Data System (ADS)

    McBride, William R.; McBride, Daniel R.

    2016-08-01

    The Daniel K. Inouye Solar Telescope (DKIST) will be the largest solar telescope in the world, with a 4-meter off-axis primary mirror and 16 meter rotating Coudé laboratory within the telescope pier. The off-axis design requires a mount similar to an 8-meter on-axis telescope. Both the telescope mount and the Coudé laboratory utilize a roller bearing technology in place of the more commonly used hydrostatic bearings. The telescope enclosure utilizes a crawler mechanism for the altitude axis. As these mechanisms have not previously been used in a telescope, understanding the vibration characteristics and the potential impact on the telescope image is important. This paper presents the methodology used to perform jitter measurements of the enclosure and the mount bearings and servo system in a high-noise environment utilizing seismic accelerometers and high dynamic-range data acquisition equipment, along with digital signal processing (DSP) techniques. Data acquisition and signal processing were implemented in MATLAB. In the factory acceptance testing of the telescope mount, multiple accelerometers were strategically located to capture the six axes-of-motion of the primary and secondary mirror dummies. The optical sensitivity analysis was used to map these mirror mount displacements and rotations into units of image motion on the focal plane. Similarly, tests were done with the Coudé rotator, treating the entire rotating instrument lab as a rigid body. Testing was performed by recording accelerometer data while the telescope control system performed tracking operations typical of various observing scenarios. The analysis of the accelerometer data utilized noise-averaging fast Fourier transform (FFT) routines, spectrograms, and periodograms. To achieve adequate dynamic range at frequencies as low as 3Hz, the use of special filters and advanced windowing functions were necessary. Numerous identical automated tests were compared to identify and select the data sets with the lowest level of external interference. Similar testing was performed on the telescope enclosure during the factory test campaign. The vibration of the enclosure altitude and azimuth mechanisms were characterized. This paper details jitter tests using accelerometers placed in locations that allowed the motion of the assemblies to be measured while the control system performed various moves typical of on-sky observations. The measurements were converted into the rigid body motion of the structures and mapped into image motion using the telescope's optical sensitivity analysis.

  16. Origin and heterogeneity of pore sizes in the Mount Simon Sandstone and Eau Claire Formation: Implications for multiphase fluid flow

    DOE PAGES

    Mozley, Peter S.; Heath, Jason E.; Dewers, Thomas A.; ...

    2016-01-01

    The Mount Simon Sandstone and Eau Claire Formation represent a principal reservoir - caprock system for wastewater disposal, geologic CO 2 storage, and compressed air energy storage (CAES) in the Midwestern United States. Of primary concern to site performance is heterogeneity in flow properties that could lead to non-ideal injectivity and distribution of injected fluids (e.g., poor sweep efficiency). Using core samples from the Dallas Center Structure, Iowa, we investigate pore structure that governs flow properties of major lithofacies of these formations. Methods include gas porosimetry and permeametry, mercury intrusion porosimetry, thin section petrography, and X-ray diffraction. The lithofacies exhibitmore » highly variable intra- and inter-informational distributions of pore throat and body sizes. Based on pore-throat size, samples fall into four distinct groups. Micropore-throat dominated samples are from the Eau Claire Formation, whereas the macropore-, mesopore-, and uniform-dominated samples are from the Mount Simon Sandstone. Complex paragenesis governs the high degree of pore and pore-throat size heterogeneity, due to an interplay of precipitation, non-uniform compaction, and later dissolution of cements. Furthermore, the cement dissolution event probably accounts for much of the current porosity in the unit. The unusually heterogeneous nature of the pore networks in the Mount Simon Sandstone indicates that there is a greater-than-normal opportunity for reservoir capillary trapping of non-wetting fluids — as quantified by CO 2 and air column heights — which should be taken into account when assessing the potential of the reservoir-caprock system for CO 2 storage and CAES.« less

  17. AutoDrug: fully automated macromolecular crystallography workflows for fragment-based drug discovery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, Yingssu; Stanford University, 333 Campus Drive, Mudd Building, Stanford, CA 94305-5080; McPhillips, Scott E.

    New software has been developed for automating the experimental and data-processing stages of fragment-based drug discovery at a macromolecular crystallography beamline. A new workflow-automation framework orchestrates beamline-control and data-analysis software while organizing results from multiple samples. AutoDrug is software based upon the scientific workflow paradigm that integrates the Stanford Synchrotron Radiation Lightsource macromolecular crystallography beamlines and third-party processing software to automate the crystallography steps of the fragment-based drug-discovery process. AutoDrug screens a cassette of fragment-soaked crystals, selects crystals for data collection based on screening results and user-specified criteria and determines optimal data-collection strategies. It then collects and processes diffraction data,more » performs molecular replacement using provided models and detects electron density that is likely to arise from bound fragments. All processes are fully automated, i.e. are performed without user interaction or supervision. Samples can be screened in groups corresponding to particular proteins, crystal forms and/or soaking conditions. A single AutoDrug run is only limited by the capacity of the sample-storage dewar at the beamline: currently 288 samples. AutoDrug was developed in conjunction with RestFlow, a new scientific workflow-automation framework. RestFlow simplifies the design of AutoDrug by managing the flow of data and the organization of results and by orchestrating the execution of computational pipeline steps. It also simplifies the execution and interaction of third-party programs and the beamline-control system. Modeling AutoDrug as a scientific workflow enables multiple variants that meet the requirements of different user groups to be developed and supported. A workflow tailored to mimic the crystallography stages comprising the drug-discovery pipeline of CoCrystal Discovery Inc. has been deployed and successfully demonstrated. This workflow was run once on the same 96 samples that the group had examined manually and the workflow cycled successfully through all of the samples, collected data from the same samples that were selected manually and located the same peaks of unmodeled density in the resulting difference Fourier maps.« less

  18. Performance Optimization of a Rotor Alone Nacelle for Acoustic Fan Testing

    NASA Technical Reports Server (NTRS)

    Cunningham, C. C.; Thompson, W. K.; Hughes, C. E.

    2000-01-01

    This paper describes the techniques, equipment, and results from the optimization of a two-axis traverse actuation system used to maintain concentricity between a sting-mounted fan and a wall-mounted nacelle in the 9 x 15 (9 Foot by 15 Foot Test Section) Low Speed Wind Tunnel (LSWT) at the NASA Glenn Research Center (GRC). The Rotor Alone Nacelle (RAN) system, developed at GRC by the Engineering Design and Analysis Division (EDAD) and the Acoustics Branch, used nacelle-mounted lasers and an automated control system to maintain concentricity as thermal and thrust operating loads displace the fan relative to the nacelle. This effort was critical to ensuring rig/facility safety and experimental consistency of the acoustic data from a statorless, externally supported nacelle configuration. Although the tip clearances were originally predicted to be about 0.020 in. at maximum rotor (fan) operating speed, proximity probe measurements showed that the nominal clearance was less than 0.004 in. As a result, the system was optimized through control-loop modifications, active laser cooling, data filtering and averaging, and the development of strict operational procedures. The resultant concentricity error of RAN was reduced to +/- 0.0031 in. in the Y-direction (horizontal) and +0.0035 in./-0.001 3 in. in the Z-direction (vertical), as determined by error analysis and experimental results. Based on the success of this project, the RAN system will be transitioned to other wind tunnel research programs at NASA GRC.

  19. Electrochemical pesticide detection with AutoDip--a portable platform for automation of crude sample analyses.

    PubMed

    Drechsel, Lisa; Schulz, Martin; von Stetten, Felix; Moldovan, Carmen; Zengerle, Roland; Paust, Nils

    2015-02-07

    Lab-on-a-chip devices hold promise for automation of complex workflows from sample to answer with minimal consumption of reagents in portable devices. However, complex, inhomogeneous samples as they occur in environmental or food analysis may block microchannels and thus often cause malfunction of the system. Here we present the novel AutoDip platform which is based on the movement of a solid phase through the reagents and sample instead of transporting a sequence of reagents through a fixed solid phase. A ball-pen mechanism operated by an external actuator automates unit operations such as incubation and washing by consecutively dipping the solid phase into the corresponding liquids. The platform is applied to electrochemical detection of organophosphorus pesticides in real food samples using an acetylcholinesterase (AChE) biosensor. Minimal sample preparation and an integrated reagent pre-storage module hold promise for easy handling of the assay. Detection of the pesticide chlorpyrifos-oxon (CPO) spiked into apple samples at concentrations of 10(-7) M has been demonstrated. This concentration is below the maximum residue level for chlorpyrifos in apples defined by the European Commission.

  20. Automated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting.

    PubMed

    Shayanfar, Noushin; Tobler, Ulrich; von Eckardstein, Arnold; Bestmann, Lukas

    2007-01-01

    Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. A total of 332 specimens were collected and analyzed for insoluble urine components by microscopy and automated analyzers, namely the Iris iQ200 (Iris Diagnostics) and the UF-100 flow cytometer (Sysmex). The coefficients of variation for day-to-day quality control of the iQ200 and UF-100 analyzers were 6.5% and 5.5%, respectively, for red blood cells. We reached accuracy ranging from 68% (bacteria) to 97% (yeast) for the iQ200 and from 42% (bacteria) to 93% (yeast) for the UF-100. The combination of dipstick and automated urine sediment analysis increased the sensitivity of screening to approximately 98%. We conclude that automated urine sediment analysis is sufficiently precise and improves the workflow in a routine laboratory. In addition, it allows sediment analysis of all urine samples and thereby helps to detect pathological samples that would have been missed in the conventional two-step procedure according to the European guidelines. Although it is not a substitute for microscopic sediment examination, it can, when combined with dipstick testing, reduce the number of specimens submitted to microscopy. Visual microscopy is still required for some samples, namely, dysmorphic erythrocytes, yeasts, Trichomonas, oval fat bodies, differentiation of casts and certain crystals.

  1. The Stability and Validity of Automated Vocal Analysis in Preverbal Preschoolers With Autism Spectrum Disorder

    PubMed Central

    Woynaroski, Tiffany; Oller, D. Kimbrough; Keceli-Kaysili, Bahar; Xu, Dongxin; Richards, Jeffrey A.; Gilkerson, Jill; Gray, Sharmistha; Yoder, Paul

    2017-01-01

    Theory and research suggest that vocal development predicts “useful speech” in preschoolers with autism spectrum disorder (ASD), but conventional methods for measurement of vocal development are costly and time consuming. This longitudinal correlational study examines the reliability and validity of several automated indices of vocalization development relative to an index derived from human coded, conventional communication samples in a sample of preverbal preschoolers with ASD. Automated indices of vocal development were derived using software that is presently “in development” and/or only available for research purposes and using commercially available Language ENvironment Analysis (LENA) software. Indices of vocal development that could be derived using the software available for research purposes: (a) were highly stable with a single day-long audio recording, (b) predicted future spoken vocabulary to a degree that was nonsignificantly different from the index derived from conventional communication samples, and (c) continued to predict future spoken vocabulary even after controlling for concurrent vocabulary in our sample. The score derived from standard LENA software was similarly stable, but was not significantly correlated with future spoken vocabulary. Findings suggest that automated vocal analysis is a valid and reliable alternative to time intensive and expensive conventional communication samples for measurement of vocal development of preverbal preschoolers with ASD in research and clinical practice. PMID:27459107

  2. Automated position control of a surface array relative to a liquid microjunction surface sampler

    DOEpatents

    Van Berkel, Gary J.; Kertesz, Vilmos; Ford, Michael James

    2007-11-13

    A system and method utilizes an image analysis approach for controlling the probe-to-surface distance of a liquid junction-based surface sampling system for use with mass spectrometric detection. Such an approach enables a hands-free formation of the liquid microjunction used to sample solution composition from the surface and for re-optimization, as necessary, of the microjunction thickness during a surface scan to achieve a fully automated surface sampling system.

  3. Automation of TL brick dating by ADAM-1

    NASA Astrophysics Data System (ADS)

    Čechák, T.; Gerndt, J.; Hiršl, P.; Jiroušek, P.; Kanaval, J.; Kubelík, M.; Musílek, L.

    2001-06-01

    A specially adapted machine ADAM-1 for the thermoluminescence fine grain dating of bricks was constructed in an interdisciplinary research project, undertaken by a team recruited from three faculties of the Czech Technical University in Prague. This TL-reader is able to measure and evaluate automatically numerous samples. The sample holder has 60 sample positions, which allow the irradiation and evaluation of samples taken from two locations. All procedures of alpha and beta irradiation by varying doses and the TL-signal measurement as also the age evaluation and error assessment are programmable and fully automated.

  4. Automation of dimethylation after guanidination labeling chemistry and its compatibility with common buffers and surfactants for mass spectrometry-based shotgun quantitative proteome analysis.

    PubMed

    Lo, Andy; Tang, Yanan; Chen, Lu; Li, Liang

    2013-07-25

    Isotope labeling liquid chromatography-mass spectrometry (LC-MS) is a major analytical platform for quantitative proteome analysis. Incorporation of isotopes used to distinguish samples plays a critical role in the success of this strategy. In this work, we optimized and automated a chemical derivatization protocol (dimethylation after guanidination, 2MEGA) to increase the labeling reproducibility and reduce human intervention. We also evaluated the reagent compatibility of this protocol to handle biological samples in different types of buffers and surfactants. A commercially available liquid handler was used for reagent dispensation to minimize analyst intervention and at least twenty protein digest samples could be prepared in a single run. Different front-end sample preparation methods for protein solubilization (SDS, urea, Rapigest™, and ProteaseMAX™) and two commercially available cell lysis buffers were evaluated for compatibility with the automated protocol. It was found that better than 94% desired labeling could be obtained in all conditions studied except urea, where the rate was reduced to about 92% due to carbamylation on the peptide amines. This work illustrates the automated 2MEGA labeling process can be used to handle a wide range of protein samples containing various reagents that are often encountered in protein sample preparation for quantitative proteome analysis. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Recent advances in head-mounted light field displays for virtual and augmented reality (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Hua, Hong

    2017-02-01

    Head-mounted light field displays render a true 3D scene by sampling either the projections of the 3D scene at different depths or the directions of the light rays apparently emitted by the 3D scene and viewed from different eye positions. They are capable of rendering correct or nearly correct focus cues and addressing the very well-known vergence-accommodation mismatch problem in conventional virtual and augmented reality displays. In this talk, I will focus on reviewing recent advancements of head-mounted light field displays for VR and AR applications. I will demonstrate examples of HMD systems developed in my group.

  6. Application of Self Nulling Eddy Current Probe Technique to the Detection of Fatigue Crack Initiation and Control of Test Procedures

    NASA Technical Reports Server (NTRS)

    Namkung, M.; Nath, S.; Wincheski, B.; Fulton, J. P.

    1994-01-01

    A major part of fracture mechanics is concerned with studying the initiation and propagation of fatigue cracks. This typically requires constant monitoring of crack growth during fatigue cycles and the knowledge of the precise location of the crack tip at any given time. One technique currently available for measuring fatigue crack length is the Potential Drop method. The method, however, may be inaccurate if the direction of crack growth deviates considerably from what was assumed initially or the curvature of the crack becomes significant. Another popular approach is to optically view the crack using a high magnification microscope, but this entails a person constantly monitoring it. The present proposed technique uses an automated scheme, in order to eliminate the need for a person to constantly monitor the experiment. Another technique under development elsewhere is to digitize an optical image of the test specimen surface and then apply a pattern recognition algorithm to locate the crack tip. A previous publication showed that the self nulling eddy current probe successfully tracked a simulated crack in an aluminum sample. This was the impetus to develop an online real time crack monitoring system. An automated system has been developed which includes a two axis scanner mounted on the tensile testing machine, the probe and its instrumentation and a personal computer (PC) to communicate and control all the parameters. The system software controls the testing parameters as well as monitoring the fatigue crack as it propagates. This paper will discuss the experimental setup in detail and demonstrate its capabilities. A three dimensional finite element model is utilized to model the magnetic field distribution due to the probe and how the probe voltage changes as it scans the crack. Experimental data of the probe for different samples under zero load, static load and high cycle fatigue load will be discussed. The final section summarizes the major accomplishments of the present work, the elements of the future R&D needs and the advantages and disadvantages of using this system in the laboratory and field.

  7. A continuous analyzer for soluble anionic constituents and ammonium in atmospheric particulate matter.

    PubMed

    Al-Horr, Rida; Samanta, Gautam; Dasgupta, Purnendu K

    2003-12-15

    A new continuous soluble particle collector (PC) that does not use steam is described. Preceded by a denuder and interfaced with an ion chromatograph, this compact collector (3 in. o.d., approximately 5 in. total height) permits collection and continuous extraction of soluble components in atmospheric particulate matter. The PC is mounted atop a parallel plate wetted denuder for removal of soluble gases. The soluble gas denuded air enters the PC through an inlet. One version of the PC contained an integral cyclone-like inlet. For this device, penetration of particles as a function of size was characterized. In the simpler design, the sampled air enters the PC through a nozzle, and deionized water flows through a capillary tube placed close to the exit side of the nozzle by Venturi action or is forcibly pumped. Some growth of the aerosol occurs in the highly humid mist-chamber environment, but the dominant aerosol capture mechanism involves capture by the water film that forms on the hydrophobic PTFE membrane filter that constitutes the top of the PC and the airflow exit. Water drops coalesce on the filter and fall below into a purpose-machined cavity equipped with a liquid sensor. The water and the dissolved constituents are aspirated by a pump onto serial cation and anion preconcentrator columns. NH4+ captured by the cation preconcentrator is eluted with NaOH and is passed across an asymmetric membrane device. NH3 diffuses from the alkaline donor stream into a deionized water flowing countercurrent; the conductivity of the latter provides a measure of ammonium. The anions on the anion preconcentrator column are eluted and measured by a fully automated ion chromatography system. The total system thus provides automated semicontinuous measurement of soluble anions and ammonium. With a 15 min analytical cycle and a sampling rate of 5 L/min, the limit of detection (LOD) for ammonium is 8 ng/m3 and those for sulfate, nitrate, and oxalate are < or = 0.1 ng/m3. The system has been extensively field tested.

  8. Clinical Chemistry Laboratory Automation in the 21st Century - Amat Victoria curam (Victory loves careful preparation)

    PubMed Central

    Armbruster, David A; Overcash, David R; Reyes, Jaime

    2014-01-01

    The era of automation arrived with the introduction of the AutoAnalyzer using continuous flow analysis and the Robot Chemist that automated the traditional manual analytical steps. Successive generations of stand-alone analysers increased analytical speed, offered the ability to test high volumes of patient specimens, and provided large assay menus. A dichotomy developed, with a group of analysers devoted to performing routine clinical chemistry tests and another group dedicated to performing immunoassays using a variety of methodologies. Development of integrated systems greatly improved the analytical phase of clinical laboratory testing and further automation was developed for pre-analytical procedures, such as sample identification, sorting, and centrifugation, and post-analytical procedures, such as specimen storage and archiving. All phases of testing were ultimately combined in total laboratory automation (TLA) through which all modules involved are physically linked by some kind of track system, moving samples through the process from beginning-to-end. A newer and very powerful, analytical methodology is liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS). LC-MS/MS has been automated but a future automation challenge will be to incorporate LC-MS/MS into TLA configurations. Another important facet of automation is informatics, including middleware, which interfaces the analyser software to a laboratory information systems (LIS) and/or hospital information systems (HIS). This software includes control of the overall operation of a TLA configuration and combines analytical results with patient demographic information to provide additional clinically useful information. This review describes automation relevant to clinical chemistry, but it must be recognised that automation applies to other specialties in the laboratory, e.g. haematology, urinalysis, microbiology. It is a given that automation will continue to evolve in the clinical laboratory, limited only by the imagination and ingenuity of laboratory scientists. PMID:25336760

  9. Clinical Chemistry Laboratory Automation in the 21st Century - Amat Victoria curam (Victory loves careful preparation).

    PubMed

    Armbruster, David A; Overcash, David R; Reyes, Jaime

    2014-08-01

    The era of automation arrived with the introduction of the AutoAnalyzer using continuous flow analysis and the Robot Chemist that automated the traditional manual analytical steps. Successive generations of stand-alone analysers increased analytical speed, offered the ability to test high volumes of patient specimens, and provided large assay menus. A dichotomy developed, with a group of analysers devoted to performing routine clinical chemistry tests and another group dedicated to performing immunoassays using a variety of methodologies. Development of integrated systems greatly improved the analytical phase of clinical laboratory testing and further automation was developed for pre-analytical procedures, such as sample identification, sorting, and centrifugation, and post-analytical procedures, such as specimen storage and archiving. All phases of testing were ultimately combined in total laboratory automation (TLA) through which all modules involved are physically linked by some kind of track system, moving samples through the process from beginning-to-end. A newer and very powerful, analytical methodology is liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS). LC-MS/MS has been automated but a future automation challenge will be to incorporate LC-MS/MS into TLA configurations. Another important facet of automation is informatics, including middleware, which interfaces the analyser software to a laboratory information systems (LIS) and/or hospital information systems (HIS). This software includes control of the overall operation of a TLA configuration and combines analytical results with patient demographic information to provide additional clinically useful information. This review describes automation relevant to clinical chemistry, but it must be recognised that automation applies to other specialties in the laboratory, e.g. haematology, urinalysis, microbiology. It is a given that automation will continue to evolve in the clinical laboratory, limited only by the imagination and ingenuity of laboratory scientists.

  10. Automated fault-management in a simulated spaceflight micro-world

    NASA Technical Reports Server (NTRS)

    Lorenz, Bernd; Di Nocera, Francesco; Rottger, Stefan; Parasuraman, Raja

    2002-01-01

    BACKGROUND: As human spaceflight missions extend in duration and distance from Earth, a self-sufficient crew will bear far greater onboard responsibility and authority for mission success. This will increase the need for automated fault management (FM). Human factors issues in the use of such systems include maintenance of cognitive skill, situational awareness (SA), trust in automation, and workload. This study examine the human performance consequences of operator use of intelligent FM support in interaction with an autonomous, space-related, atmospheric control system. METHODS: An expert system representing a model-base reasoning agent supported operators at a low level of automation (LOA) by a computerized fault finding guide, at a medium LOA by an automated diagnosis and recovery advisory, and at a high LOA by automate diagnosis and recovery implementation, subject to operator approval or veto. Ten percent of the experimental trials involved complete failure of FM support. RESULTS: Benefits of automation were reflected in more accurate diagnoses, shorter fault identification time, and reduced subjective operator workload. Unexpectedly, fault identification times deteriorated more at the medium than at the high LOA during automation failure. Analyses of information sampling behavior showed that offloading operators from recovery implementation during reliable automation enabled operators at high LOA to engage in fault assessment activities CONCLUSIONS: The potential threat to SA imposed by high-level automation, in which decision advisories are automatically generated, need not inevitably be counteracted by choosing a lower LOA. Instead, freeing operator cognitive resources by automatic implementation of recover plans at a higher LOA can promote better fault comprehension, so long as the automation interface is designed to support efficient information sampling.

  11. Automated processing of whole blood samples for the determination of immunosuppressants by liquid chromatography tandem-mass spectrometry.

    PubMed

    Vogeser, Michael; Spöhrer, Ute

    2006-01-01

    Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is an efficient technology for routine determination of immunosuppressants in whole blood; however, time-consuming manual sample preparation remains a significant limitation of this technique. Using a commercially available robotic pipetting system (Tecan Freedom EVO), we developed an automated sample-preparation protocol for quantification of tacrolimus in whole blood by LC-MS/MS. Barcode reading, sample resuspension, transfer of whole blood aliquots into a deep-well plate, addition of internal standard solution, mixing, and protein precipitation by addition of an organic solvent is performed by the robotic system. After centrifugation of the plate, the deproteinized supernatants are submitted to on-line solid phase extraction, using column switching prior to LC-MS/MS analysis. The only manual actions within the entire process are decapping of the tubes, and transfer of the deep-well plate from the robotic system to a centrifuge and finally to the HPLC autosampler. Whole blood pools were used to assess the reproducibility of the entire analytical system for measuring tacrolimus concentrations. A total coefficient of variation of 1.7% was found for the entire automated analytical process (n=40; mean tacrolimus concentration, 5.3 microg/L). Close agreement between tacrolimus results obtained after manual and automated sample preparation was observed. The analytical system described here, comprising automated protein precipitation, on-line solid phase extraction and LC-MS/MS analysis, is convenient and precise, and minimizes hands-on time and the risk of mistakes in the quantification of whole blood immunosuppressant concentrations compared to conventional methods.

  12. Automated cellular sample preparation using a Centrifuge-on-a-Chip.

    PubMed

    Mach, Albert J; Kim, Jae Hyun; Arshi, Armin; Hur, Soojung Claire; Di Carlo, Dino

    2011-09-07

    The standard centrifuge is a laboratory instrument widely used by biologists and medical technicians for preparing cell samples. Efforts to automate the operations of concentration, cell separation, and solution exchange that a centrifuge performs in a simpler and smaller platform have had limited success. Here, we present a microfluidic chip that replicates the functions of a centrifuge without moving parts or external forces. The device operates using a purely fluid dynamic phenomenon in which cells selectively enter and are maintained in microscale vortices. Continuous and sequential operation allows enrichment of cancer cells from spiked blood samples at the mL min(-1) scale, followed by fluorescent labeling of intra- and extra-cellular antigens on the cells without the need for manual pipetting and washing steps. A versatile centrifuge-analogue may open opportunities in automated, low-cost and high-throughput sample preparation as an alternative to the standard benchtop centrifuge in standardized clinical diagnostics or resource poor settings.

  13. Imaging a Large Sample with Selective Plane Illumination Microscopy Based on Multiple Fluorescent Microsphere Tracking

    NASA Astrophysics Data System (ADS)

    Ryu, Inkeon; Kim, Daekeun

    2018-04-01

    A typical selective plane illumination microscopy (SPIM) image size is basically limited by the field of view, which is a characteristic of the objective lens. If an image larger than the imaging area of the sample is to be obtained, image stitching, which combines step-scanned images into a single panoramic image, is required. However, accurately registering the step-scanned images is very difficult because the SPIM system uses a customized sample mount where uncertainties for the translational and the rotational motions exist. In this paper, an image registration technique based on multiple fluorescent microsphere tracking is proposed in the view of quantifying the constellations and measuring the distances between at least two fluorescent microspheres embedded in the sample. Image stitching results are demonstrated for optically cleared large tissue with various staining methods. Compensation for the effect of the sample rotation that occurs during the translational motion in the sample mount is also discussed.

  14. Automation system for neutron activation analysis at the reactor IBR-2, Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, Dubna, Russia.

    PubMed

    Pavlov, Sergey S; Dmitriev, Andrey Yu; Frontasyeva, Marina V

    The present status of development of software packages and equipment designed for automation of NAA at the reactor IBR-2 of FLNP, JINR, Dubna, RF, is described. The NAA database, construction of sample changers and software for automation of spectra measurement and calculation of concentrations are presented. Automation of QC procedures is integrated in the software developed. Details of the design are shown.

  15. Automated Sample Preparation for Radiogenic and Non-Traditional Metal Isotopes: Removing an Analytical Barrier for High Sample Throughput

    NASA Astrophysics Data System (ADS)

    Field, M. Paul; Romaniello, Stephen; Gordon, Gwyneth W.; Anbar, Ariel D.; Herrmann, Achim; Martinez-Boti, Miguel A.; Anagnostou, Eleni; Foster, Gavin L.

    2014-05-01

    MC-ICP-MS has dramatically improved the analytical throughput for high-precision radiogenic and non-traditional isotope ratio measurements, compared to TIMS. The generation of large data sets, however, remains hampered by tedious manual drip chromatography required for sample purification. A new, automated chromatography system reduces the laboratory bottle neck and expands the utility of high-precision isotope analyses in applications where large data sets are required: geochemistry, forensic anthropology, nuclear forensics, medical research and food authentication. We have developed protocols to automate ion exchange purification for several isotopic systems (B, Ca, Fe, Cu, Zn, Sr, Cd, Pb and U) using the new prepFAST-MC™ (ESI, Nebraska, Omaha). The system is not only inert (all-flouropolymer flow paths), but is also very flexible and can easily facilitate different resins, samples, and reagent types. When programmed, precise and accurate user defined volumes and flow rates are implemented to automatically load samples, wash the column, condition the column and elute fractions. Unattended, the automated, low-pressure ion exchange chromatography system can process up to 60 samples overnight. Excellent reproducibility, reliability, recovery, with low blank and carry over for samples in a variety of different matrices, have been demonstrated to give accurate and precise isotopic ratios within analytical error for several isotopic systems (B, Ca, Fe, Cu, Zn, Sr, Cd, Pb and U). This illustrates the potential of the new prepFAST-MC™ (ESI, Nebraska, Omaha) as a powerful tool in radiogenic and non-traditional isotope research.

  16. Automation of diagnostic genetic testing: mutation detection by cyclic minisequencing.

    PubMed

    Alagrund, Katariina; Orpana, Arto K

    2014-01-01

    The rising role of nucleic acid testing in clinical decision making is creating a need for efficient and automated diagnostic nucleic acid test platforms. Clinical use of nucleic acid testing sets demands for shorter turnaround times (TATs), lower production costs and robust, reliable methods that can easily adopt new test panels and is able to run rare tests in random access principle. Here we present a novel home-brew laboratory automation platform for diagnostic mutation testing. This platform is based on the cyclic minisequecing (cMS) and two color near-infrared (NIR) detection. Pipetting is automated using Tecan Freedom EVO pipetting robots and all assays are performed in 384-well micro plate format. The automation platform includes a data processing system, controlling all procedures, and automated patient result reporting to the hospital information system. We have found automated cMS a reliable, inexpensive and robust method for nucleic acid testing for a wide variety of diagnostic tests. The platform is currently in clinical use for over 80 mutations or polymorphisms. Additionally to tests performed from blood samples, the system performs also epigenetic test for the methylation of the MGMT gene promoter, and companion diagnostic tests for analysis of KRAS and BRAF gene mutations from formalin fixed and paraffin embedded tumor samples. Automation of genetic test reporting is found reliable and efficient decreasing the work load of academic personnel.

  17. An Automated Sample Processing System for Planetary Exploration

    NASA Technical Reports Server (NTRS)

    Soto, Juancarlos; Lasnik, James; Roark, Shane; Beegle, Luther

    2012-01-01

    An Automated Sample Processing System (ASPS) for wet chemistry processing of organic materials on the surface of Mars has been jointly developed by Ball Aerospace and the Jet Propulsion Laboratory. The mechanism has been built and tested to demonstrate TRL level 4. This paper describes the function of the system, mechanism design, lessons learned, and several challenges that were overcome.

  18. Re-Emergence of Under-Selected Stimuli, after the Extinction of Over-Selected Stimuli in an Automated Match to Samples Procedure

    ERIC Educational Resources Information Center

    Broomfield, Laura; McHugh, Louise; Reed, Phil

    2008-01-01

    Stimulus over-selectivity occurs when one of potentially many aspects of the environment comes to control behaviour. In two experiments, adults with no developmental disabilities, were trained and tested in an automated match to samples (MTS) paradigm. In Experiment 1, participants completed two conditions, in one of which the over-selected…

  19. Determination of nitrite and nitrate in water samples by an automated hydrodynamic sequential injection method.

    PubMed

    Somnam, Sarawut; Jakmunee, Jaroon; Grudpan, Kate; Lenghor, Narong; Motomizu, Shoji

    2008-12-01

    An automated hydrodynamic sequential injection (HSI) system with spectrophotometric detection was developed. Thanks to the hydrodynamic injection principle, simple devices can be used for introducing reproducible microliter volumes of both sample and reagent into the flow channel to form stacked zones in a similar fashion to those in a sequential injection system. The zones were then pushed to the detector and a peak profile was recorded. The determination of nitrite and nitrate in water samples by employing the Griess reaction was chosen as a model. Calibration graphs with linearity in the range of 0.7 - 40 muM were obtained for both nitrite and nitrate. Detection limits were found to be 0.3 muM NO(2)(-) and 0.4 muM NO(3)(-), respectively, with a sample throughput of 20 h(-1) for consecutive determination of both the species. The developed system was successfully applied to the analysis of water samples, employing simple and cost-effective instrumentation and offering higher degrees of automation and low chemical consumption.

  20. A novel flow injection chemiluminescence method for automated and miniaturized determination of phenols in smoked food samples.

    PubMed

    Vakh, Christina; Evdokimova, Ekaterina; Pochivalov, Aleksei; Moskvin, Leonid; Bulatov, Andrey

    2017-12-15

    An easily performed fully automated and miniaturized flow injection chemiluminescence (CL) method for determination of phenols in smoked food samples has been proposed. This method includes the ultrasound assisted solid-liquid extraction coupled with gas-diffusion separation of phenols from smoked food sample and analytes absorption into a NaOH solution in a specially designed gas-diffusion cell. The flow system was designed to focus on automation and miniaturization with minimal sample and reagent consumption by inexpensive instrumentation. The luminol - N-bromosuccinimide system in an alkaline medium was used for the CL determination of phenols. The limit of detection of the proposed procedure was 3·10 -8 ·molL -1 (0.01mgkg -1 ) in terms of phenol. The presented method demonstrated to be a good tool for easy, rapid and cost-effective point-of-need screening phenols in smoked food samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Automated Sensitivity Analysis of Interplanetary Trajectories

    NASA Technical Reports Server (NTRS)

    Knittel, Jeremy; Hughes, Kyle; Englander, Jacob; Sarli, Bruno

    2017-01-01

    This work describes a suite of Python tools known as the Python EMTG Automated Trade Study Application (PEATSA). PEATSA was written to automate the operation of trajectory optimization software, simplify the process of performing sensitivity analysis, and was ultimately found to out-perform a human trajectory designer in unexpected ways. These benefits will be discussed and demonstrated on sample mission designs.

  2. Automation of laboratory testing for infectious diseases using the polymerase chain reaction-- our past, our present, our future.

    PubMed

    Jungkind, D

    2001-01-01

    While it is an extremely powerful and versatile assay method, polymerase chain reaction (PCR) can be a labor-intensive process. Since the advent of commercial test kits from Roche and the semi-automated microwell Amplicor system, PCR has become an increasingly useful and widespread clinical tool. However, more widespread acceptance of molecular testing will depend upon automation that allows molecular assays to enter the routine clinical laboratory. The forces driving the need for automated PCR are the requirements for diagnosis and treatment of chronic viral diseases, economic pressures to develop more automated and less expensive test procedures similar to those in the clinical chemistry laboratories, and a shortage in many areas of qualified laboratory personnel trained in the types of manual procedures used in past decades. The automated Roche COBAS AMPLICOR system has automated the amplification and detection process. Specimen preparation remains the most labor-intensive part of the PCR testing process, accounting for the majority of the hands-on-time in most of the assays. A new automated specimen preparation system, the COBAS AmpliPrep, was evaluated. The system automatically releases the target nucleic acid, captures the target with specific oligonucleotide probes, which become attached to magnetic beads via a biotin-streptavidin binding reaction. Once attached to the beads, the target is purified and concentrated automatically. Results of 298 qualitative and 57 quantitative samples representing a wide range of virus concentrations analyzed after the COBAS AmpliPrep and manual specimen preparation methods, showed that there was no significant difference in qualitative or quantitative hepatitis C virus (HCV) assay performance, respectively. The AmpliPrep instrument decreased the time required to prepare serum or plasma samples for HCV PCR to under 1 min per sample. This was a decrease of 76% compared to the manual specimen preparation method. Systems that can analyze more samples with higher throughput and that can answer more questions about the nature of the microbes that we can presently only detect and quantitate will be needed in the future.

  3. Application of automation and information systems to forensic genetic specimen processing.

    PubMed

    Leclair, Benoît; Scholl, Tom

    2005-03-01

    During the last 10 years, the introduction of PCR-based DNA typing technologies in forensic applications has been highly successful. This technology has become pervasive throughout forensic laboratories and it continues to grow in prevalence. For many criminal cases, it provides the most probative evidence. Criminal genotype data banking and victim identification initiatives that follow mass-fatality incidents have benefited the most from the introduction of automation for sample processing and data analysis. Attributes of offender specimens including large numbers, high quality and identical collection and processing are ideal for the application of laboratory automation. The magnitude of kinship analysis required by mass-fatality incidents necessitates the application of computing solutions to automate the task. More recently, the development activities of many forensic laboratories are focused on leveraging experience from these two applications to casework sample processing. The trend toward increased prevalence of forensic genetic analysis will continue to drive additional innovations in high-throughput laboratory automation and information systems.

  4. Viscoelastic characterization of soft biological materials

    NASA Astrophysics Data System (ADS)

    Nayar, Vinod Timothy

    Progressive and irreversible retinal diseases are among the primary causes of blindness in the United States, attacking the cells in the eye that transform environmental light into neural signals for the optic pathway. Medical implants designed to restore visual function to afflicted patients can cause mechanical stress and ultimately damage to the host tissues. Research shows that an accurate understanding of the mechanical properties of the biological tissues can reduce damage and lead to designs with improved safety and efficacy. Prior studies on the mechanical properties of biological tissues show characterization of these materials can be affected by environmental, length-scale, time, mounting, stiffness, size, viscoelastic, and methodological conditions. Using porcine sclera tissue, the effects of environmental, time, and mounting conditions are evaluated when using nanoindentation. Quasi-static tests are used to measure reduced modulus during extended exposure to phosphate-buffered saline (PBS), as well as the chemical and mechanical analysis of mounting the sample to a solid substrate using cyanoacrylate. The less destructive nature of nanoindentation tests allows for variance of tests within a single sample to be compared to the variance between samples. The results indicate that the environmental, time, and mounting conditions can be controlled for using modified nanoindentation procedures for biological samples and are in line with averages modulus values from previous studies but with increased precision. By using the quasi-static and dynamic characterization capabilities of the nanoindentation setup, the additional stiffness and viscoelastic variables are measured. Different quasi-static control methods were evaluated along with maximum load parameters and produced no significant difference in reported reduced modulus values. Dynamic characterization tests varied frequency and quasi-static load, showing that the agar could be modeled as a linearly elastic material. The effects of sample stiffness were evaluated by testing both the quasi-static and dynamic mechanical properties of different concentration agar samples, ranging from 0.5% to 5.0%. The dynamic nanoindentation protocol showed some sensitivity to sample stiffness, but characterization remained consistently applicable to soft biological materials. Comparative experiments were performed on both 0.5% and 5.0% agar as well as porcine eye tissue samples using published dynamic macrocompression standards. By comparing these new tests to those obtained with nanoindentation, the effects due to length-scale, stiffness, size, viscoelastic, and methodological conditions are evaluated. Both testing methodologies can be adapted for the environmental and mounting conditions, but the limitations of standardized macro-scale tests are explored. The factors affecting mechanical characterization of soft and thin viscoelastic biological materials are researched and a comprehensive protocol is presented. This work produces material mechanical properties for use in improving future medical implant designs on a wide variety of biological tissue and materials.

  5. Evaluation of physical health effects due to volcanic hazards: crystalline silica in Mount St. Helens volcanic ash.

    PubMed

    Dollberg, D D; Bolyard, M L; Smith, D L

    1986-03-01

    This investigation has shown that crystalline silica has been identified as being present in the Mount St. Helens volcanic ash at levels of 3 to 7 per cent by weight. This identification has been established using X-ray powder diffraction, infrared spectrophotometry, visible spectrophotometry, electron microscopy, and Laser Raman spectrophotometry. Quantitative analysis by IR, XRD, and visible spectrophotometry requires a preliminary phosphoric acid digestion of the ash sample to remove the plagioclase silicate material which interferes with the determination by these methods. Electron microscopic analysis as well as Laser Raman spectrophotometric analysis of the untreated ash confirms the presence of silica and at levels found by the XRD and IR analysis of the treated samples. An interlaboratory study of volcanic ash samples by 15 laboratories confirms the presence and levels of crystalline silica. Although several problems with applying the digestion procedure were observed in this hastily organized supply, all laboratories employing the digestion procedure reported the presence of crystalline silica. These results unequivocally put to rest the question of the presence of silica in the volcanic ash from eruptions of Mount St. Helens in 1980.

  6. Automated recording of home cage activity and temperature of individual rats housed in social groups: The Rodent Big Brother project

    PubMed Central

    Tse, Karen; Grant, Claire; Keerie, Amy; Simpson, David J.; Pedersen, John C.; Rimmer, Victoria; Leslie, Lauren; Klein, Stephanie K.; Karp, Natasha A.; Sillito, Rowland; Chartsias, Agis; Lukins, Tim; Heward, James; Vickers, Catherine; Chapman, Kathryn; Armstrong, J. Douglas

    2017-01-01

    Measuring the activity and temperature of rats is commonly required in biomedical research. Conventional approaches necessitate single housing, which affects their behavior and wellbeing. We have used a subcutaneous radiofrequency identification (RFID) transponder to measure ambulatory activity and temperature of individual rats when group-housed in conventional, rack-mounted home cages. The transponder location and temperature is detected by a matrix of antennae in a baseplate under the cage. An infrared high-definition camera acquires side-view video of the cage and also enables automated detection of vertical activity. Validation studies showed that baseplate-derived ambulatory activity correlated well with manual tracking and with side-view whole-cage video pixel movement. This technology enables individual behavioral and temperature data to be acquired continuously from group-housed rats in their familiar, home cage environment. We demonstrate its ability to reliably detect naturally occurring behavioral effects, extending beyond the capabilities of routine observational tests and conventional monitoring equipment. It has numerous potential applications including safety pharmacology, toxicology, circadian biology, disease models and drug discovery. PMID:28877172

  7. An automated extinction and sky brightness monitor for the Indian Astronomical Observatory, Hanle

    NASA Astrophysics Data System (ADS)

    Sharma, Tarun Kumar; Parihar, Padmakar; Banyal, R. K.; Dar, Ajaz Ahmad; Kemkar, P. M. M.; Stanzin, Urgain; Anupama, G. C.

    2017-09-01

    We have developed a simple and portable device that makes precise and automated measurements of night sky extinction. Our instrument uses a commercially available telephoto lens for light collection, which is retrofitted to a custom-built telescope mount, a thermoelectrically cooled CCD for imaging, and a compact enclosure with electronic control to facilitate remote observations. The instrument is also capable of measuring the sky brightness and detecting the presence of thin clouds that otherwise would remain unnoticed. The measurements of sky brightness made by our simple device are more accurate than those made using a large telescope. Another capability of the device is that it can provide an instantaneous measurement of atmospheric extinction, which is extremely useful for exploring the nature of short-term extinction variation. The instrument was designed and developed primarily in order to characterize and investigate thoroughly the Indian Astronomical Observatory (IAO), Hanle for the establishment of India's future large-telescope project. The device was installed at the IAO, Hanle in 2014 May. In this paper, we present the instrument details and discuss the results of extinction data collected for about 250 nights.

  8. Automated Identification of Northern Leaf Blight-Infected Maize Plants from Field Imagery Using Deep Learning.

    PubMed

    DeChant, Chad; Wiesner-Hanks, Tyr; Chen, Siyuan; Stewart, Ethan L; Yosinski, Jason; Gore, Michael A; Nelson, Rebecca J; Lipson, Hod

    2017-11-01

    Northern leaf blight (NLB) can cause severe yield loss in maize; however, scouting large areas to accurately diagnose the disease is time consuming and difficult. We demonstrate a system capable of automatically identifying NLB lesions in field-acquired images of maize plants with high reliability. This approach uses a computational pipeline of convolutional neural networks (CNNs) that addresses the challenges of limited data and the myriad irregularities that appear in images of field-grown plants. Several CNNs were trained to classify small regions of images as containing NLB lesions or not; their predictions were combined into separate heat maps, then fed into a final CNN trained to classify the entire image as containing diseased plants or not. The system achieved 96.7% accuracy on test set images not used in training. We suggest that such systems mounted on aerial- or ground-based vehicles can help in automated high-throughput plant phenotyping, precision breeding for disease resistance, and reduced pesticide use through targeted application across a variety of plant and disease categories.

  9. Automated recording of home cage activity and temperature of individual rats housed in social groups: The Rodent Big Brother project.

    PubMed

    Redfern, William S; Tse, Karen; Grant, Claire; Keerie, Amy; Simpson, David J; Pedersen, John C; Rimmer, Victoria; Leslie, Lauren; Klein, Stephanie K; Karp, Natasha A; Sillito, Rowland; Chartsias, Agis; Lukins, Tim; Heward, James; Vickers, Catherine; Chapman, Kathryn; Armstrong, J Douglas

    2017-01-01

    Measuring the activity and temperature of rats is commonly required in biomedical research. Conventional approaches necessitate single housing, which affects their behavior and wellbeing. We have used a subcutaneous radiofrequency identification (RFID) transponder to measure ambulatory activity and temperature of individual rats when group-housed in conventional, rack-mounted home cages. The transponder location and temperature is detected by a matrix of antennae in a baseplate under the cage. An infrared high-definition camera acquires side-view video of the cage and also enables automated detection of vertical activity. Validation studies showed that baseplate-derived ambulatory activity correlated well with manual tracking and with side-view whole-cage video pixel movement. This technology enables individual behavioral and temperature data to be acquired continuously from group-housed rats in their familiar, home cage environment. We demonstrate its ability to reliably detect naturally occurring behavioral effects, extending beyond the capabilities of routine observational tests and conventional monitoring equipment. It has numerous potential applications including safety pharmacology, toxicology, circadian biology, disease models and drug discovery.

  10. An Automated, High-Throughput System for GISAXS and GIWAXS Measurements of Thin Films

    NASA Astrophysics Data System (ADS)

    Schaible, Eric; Jimenez, Jessica; Church, Matthew; Lim, Eunhee; Stewart, Polite; Hexemer, Alexander

    Grazing incidence small-angle X-ray scattering (GISAXS) and grazing incidence wide-angle X-ray scattering (GIWAXS) are important techniques for characterizing thin films. In order to meet rapidly increasing demand, the SAXSWAXS beamline at the Advanced Light Source (beamline 7.3.3) has implemented a fully automated, high-throughput system to conduct SAXS, GISAXS and GIWAXS measurements. An automated robot arm transfers samples from a holding tray to a measurement stage. Intelligent software aligns each sample in turn, and measures each according to user-defined specifications. Users mail in trays of samples on individually barcoded pucks, and can download and view their data remotely. Data will be pipelined to the NERSC supercomputing facility, and will be available to users via a web portal that facilitates highly parallelized analysis.

  11. A Study on the Effect of Ageing and Intermetallic Compound Growth on the Shear Strength of Surface Mount Technology Solder Joints

    NASA Astrophysics Data System (ADS)

    Nath, Jyotishman; Mallik, Sabuj; Borah, Anil

    2015-04-01

    The effect of ageing and intermetallic compound formation on the surface mount solder joints and its shear strength behavior under extreme mechanical and thermal conditions have been discussed in this paper. The specimens used are solder paste (Sn3.8Ag0.7Cu), bench marker II printed circuit boards (PCB), resistors 1206 and the fabrication of solder joints makes use of conventional surface mount technology (SMT). Reflow process was carried out at a peak temperature of 250 °C and the test samples were exposed to isothermal ageing at a constant temperature of 150 °C for a period of 600 h. Shear test was conducted on the PCB's. The shear strength of the solder joints rapidly increased during isothermal ageing to a certain time period and then started decreasing. Field emission scanning electron microscopy (FESEM) micrograph of the solder joint and energy dispersive X-ray (EDX) was performed on the solder sample to verify the formation of intermetallic compounds.

  12. Quantitative and qualitative measure of intralaboratory two-dimensional protein gel reproducibility and the effects of sample preparation, sample load, and image analysis.

    PubMed

    Choe, Leila H; Lee, Kelvin H

    2003-10-01

    We investigate one approach to assess the quantitative variability in two-dimensional gel electrophoresis (2-DE) separations based on gel-to-gel variability, sample preparation variability, sample load differences, and the effect of automation on image analysis. We observe that 95% of spots present in three out of four replicate gels exhibit less than a 0.52 coefficient of variation (CV) in fluorescent stain intensity (% volume) for a single sample run on multiple gels. When four parallel sample preparations are performed, this value increases to 0.57. We do not observe any significant change in quantitative value for an increase or decrease in sample load of 30% when using appropriate image analysis variables. Increasing use of automation, while necessary in modern 2-DE experiments, does change the observed level of quantitative and qualitative variability among replicate gels. The number of spots that change qualitatively for a single sample run in parallel varies from a CV = 0.03 for fully manual analysis to CV = 0.20 for a fully automated analysis. We present a systematic method by which a single laboratory can measure gel-to-gel variability using only three gel runs.

  13. Technical note: Preservation of Trichomonas vaginalis viability in urine for laboratorial diagnosis by the wet mount examination.

    PubMed

    da Silva Dias, Mariana; Menezes, Camila Braz; Tasca, Tiana

    2016-11-01

    This study compared preservative solutions at different temperatures aiming to improve the wet mount for trichomoniasis diagnosis. The glucose-saline pH6.0 solution preserved the trophozoites up to 6h. The urine samples preservation is crucial for diagnosis and we suggest this solution as part of the clinical laboratorial routine. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Automated Classification and Analysis of Non-metallic Inclusion Data Sets

    NASA Astrophysics Data System (ADS)

    Abdulsalam, Mohammad; Zhang, Tongsheng; Tan, Jia; Webler, Bryan A.

    2018-05-01

    The aim of this study is to utilize principal component analysis (PCA), clustering methods, and correlation analysis to condense and examine large, multivariate data sets produced from automated analysis of non-metallic inclusions. Non-metallic inclusions play a major role in defining the properties of steel and their examination has been greatly aided by automated analysis in scanning electron microscopes equipped with energy dispersive X-ray spectroscopy. The methods were applied to analyze inclusions on two sets of samples: two laboratory-scale samples and four industrial samples from a near-finished 4140 alloy steel components with varying machinability. The laboratory samples had well-defined inclusions chemistries, composed of MgO-Al2O3-CaO, spinel (MgO-Al2O3), and calcium aluminate inclusions. The industrial samples contained MnS inclusions as well as (Ca,Mn)S + calcium aluminate oxide inclusions. PCA could be used to reduce inclusion chemistry variables to a 2D plot, which revealed inclusion chemistry groupings in the samples. Clustering methods were used to automatically classify inclusion chemistry measurements into groups, i.e., no user-defined rules were required.

  15. Opportunistic parasites among immunosuppressed children in Minia District, Egypt.

    PubMed

    Abdel-Hafeez, Ekhlas H; Ahmad, Azza K; Ali, Basma A; Moslam, Fadia A

    2012-03-01

    A total of 450 stool samples were collected from inpatient and outpatient clinics of Pediatric Department, Minia University Hospital, Minia District, Egypt. Two groups of patients were studied, including 200 immunosuppressed and 250 immunocompetent children. Stool samples were subjected to wet saline and iodine mounts. A concentration technique (formol-ether sedimentation method) was carried out for stool samples diagnosed negative by wet saline and iodine mounts. Samples were stained by 2 different methods; acid fast stain (modified Ziehl-Neelsen stain) and Giemsa stain. Total 188 cases (94%) were diagnosed positive for parasitic infections among immunosuppressed children, whereas 150 cases (60%) were positive in immunocompetent children (P<0.0001). The most common protozoan infection in immunosuppressed group was Cryptosporidium parvum (60.2%), followed by Blastocystis hominis (12.1%), Isospora belli (9.7%), and Cyclospora caytenensis (7.8%). On the other hand, Entamoeba histolytica (24.6%) and Giardia lamblia (17.6%) were more common than other protozoans in immunocompetent children.

  16. [DNA extraction from bones and teeth using AutoMate Express forensic DNA extraction system].

    PubMed

    Gao, Lin-Lin; Xu, Nian-Lai; Xie, Wei; Ding, Shao-Cheng; Wang, Dong-Jing; Ma, Li-Qin; Li, You-Ying

    2013-04-01

    To explore a new method in order to extract DNA from bones and teeth automatically. Samples of 33 bones and 15 teeth were acquired by freeze-mill method and manual method, respectively. DNA materials were extracted and quantified from the triturated samples by AutoMate Express forensic DNA extraction system. DNA extraction from bones and teeth were completed in 3 hours using the AutoMate Express forensic DNA extraction system. There was no statistical difference between the two methods in the DNA concentration of bones. Both bones and teeth got the good STR typing by freeze-mill method, and the DNA concentration of teeth was higher than those by manual method. AutoMate Express forensic DNA extraction system is a new method to extract DNA from bones and teeth, which can be applied in forensic practice.

  17. Cost assessment of the automated VERSANT 440 Molecular System versus the semi-automated System 340 bDNA Analyzer platforms.

    PubMed

    Elbeik, Tarek; Loftus, Richard A; Beringer, Scott

    2007-11-01

    Labor, supply and waste were evaluated for HIV-1 and HCV bDNA on the semi-automated System 340 bDNA Analyzer and the automated VERSANT 440 Molecular System (V440). HIV-1 sample processing was evaluated using a 24- and 48-position centrifuge rotor. Vigilance time (hands-on manipulations plus incubation time except initial target hybridization) and disposables were approximately 37 and 12% lower for HIV-1, and 64 and 31% lower for HCV bDNA, respectively, with V440. Biohazardous solid waste was approximately twofold lower for both assays and other waste types were the same for either assay on both platforms. HIV-1 sample processing vigilance time for the 48-position rotor was reduced by 2 h. V440 provides cost savings and improved workflow.

  18. A Versatile Mounting Method for Long Term Imaging of Zebrafish Development.

    PubMed

    Hirsinger, Estelle; Steventon, Ben

    2017-01-26

    Zebrafish embryos offer an ideal experimental system to study complex morphogenetic processes due to their ease of accessibility and optical transparency. In particular, posterior body elongation is an essential process in embryonic development by which multiple tissue deformations act together to direct the formation of a large part of the body axis. In order to observe this process by long-term time-lapse imaging it is necessary to utilize a mounting technique that allows sufficient support to maintain samples in the correct orientation during transfer to the microscope and acquisition. In addition, the mounting must also provide sufficient freedom of movement for the outgrowth of the posterior body region without affecting its normal development. Finally, there must be a certain degree in versatility of the mounting method to allow imaging on diverse imaging set-ups. Here, we present a mounting technique for imaging the development of posterior body elongation in the zebrafish D. rerio. This technique involves mounting embryos such that the head and yolk sac regions are almost entirely included in agarose, while leaving out the posterior body region to elongate and develop normally. We will show how this can be adapted for upright, inverted and vertical light-sheet microscopy set-ups. While this protocol focuses on mounting embryos for imaging for the posterior body, it could easily be adapted for the live imaging of multiple aspects of zebrafish development.

  19. Portable Automation of Static Chamber Sample Collection for Quantifying Soil Gas Flux

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Morgan P.; Groh, Tyler A.; Parkin, Timothy B.

    Quantification of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled is limited by the spacing between chambers and the availability of trained research technicians. An automated system for collecting gas samples from chambers in the field would eliminate the need for personnel to return to the chamber during a flux measurement period and would allow a single technician to sample multiple chambers simultaneously. This study describes Chamber Automated Sampling Equipment (FluxCASE) to collect and store chamber headspace gas samples at assigned time points for the measurement of soil gasmore » flux. The FluxCASE design and operation is described, and the accuracy and precision of the FluxCASE system is evaluated. In laboratory measurements of nitrous oxide (N2O), carbon dioxide (CO2), and methane (CH4) concentrations of a standardized gas mixture, coefficients of variation associated with automated and manual sample collection were comparable, indicating no loss of precision. In the field, soil gas fluxes measured from FluxCASEs were in agreement with manual sampling for both N2O and CO2. Slopes of regression equations were 1.01 for CO2 and 0.97 for N2O. The 95% confidence limits of the slopes of the regression lines included the value of one, indicating no bias. Additionally, an expense analysis found a cost recovery ranging from 0.6 to 2.2 yr. Implementing the FluxCASE system is an alternative to improve the efficiency of the static chamber method for measuring soil gas flux while maintaining the accuracy and precision of manual sampling.« less

  20. Automated image analysis for quantitative fluorescence in situ hybridization with environmental samples.

    PubMed

    Zhou, Zhi; Pons, Marie Noëlle; Raskin, Lutgarde; Zilles, Julie L

    2007-05-01

    When fluorescence in situ hybridization (FISH) analyses are performed with complex environmental samples, difficulties related to the presence of microbial cell aggregates and nonuniform background fluorescence are often encountered. The objective of this study was to develop a robust and automated quantitative FISH method for complex environmental samples, such as manure and soil. The method and duration of sample dispersion were optimized to reduce the interference of cell aggregates. An automated image analysis program that detects cells from 4',6'-diamidino-2-phenylindole (DAPI) micrographs and extracts the maximum and mean fluorescence intensities for each cell from corresponding FISH images was developed with the software Visilog. Intensity thresholds were not consistent even for duplicate analyses, so alternative ways of classifying signals were investigated. In the resulting method, the intensity data were divided into clusters using fuzzy c-means clustering, and the resulting clusters were classified as target (positive) or nontarget (negative). A manual quality control confirmed this classification. With this method, 50.4, 72.1, and 64.9% of the cells in two swine manure samples and one soil sample, respectively, were positive as determined with a 16S rRNA-targeted bacterial probe (S-D-Bact-0338-a-A-18). Manual counting resulted in corresponding values of 52.3, 70.6, and 61.5%, respectively. In two swine manure samples and one soil sample 21.6, 12.3, and 2.5% of the cells were positive with an archaeal probe (S-D-Arch-0915-a-A-20), respectively. Manual counting resulted in corresponding values of 22.4, 14.0, and 2.9%, respectively. This automated method should facilitate quantitative analysis of FISH images for a variety of complex environmental samples.

  1. The feasibility of automated online flow cytometry for in-situ monitoring of microbial dynamics in aquatic ecosystems

    PubMed Central

    Besmer, Michael D.; Weissbrodt, David G.; Kratochvil, Bradley E.; Sigrist, Jürg A.; Weyland, Mathias S.; Hammes, Frederik

    2014-01-01

    Fluorescent staining coupled with flow cytometry (FCM) is often used for the monitoring, quantification and characterization of bacteria in engineered and environmental aquatic ecosystems including seawater, freshwater, drinking water, wastewater, and industrial bioreactors. However, infrequent grab sampling hampers accurate characterization and subsequent understanding of microbial dynamics in all of these ecosystems. A logic technological progression is high throughput and full automation of the sampling, staining, measurement, and data analysis steps. Here we assess the feasibility and applicability of automated FCM by means of actual data sets produced with prototype instrumentation. As proof-of-concept we demonstrate examples of microbial dynamics in (i) flowing tap water from a municipal drinking water supply network and (ii) river water from a small creek subject to two rainfall events. In both cases, automated measurements were done at 15-min intervals during 12–14 consecutive days, yielding more than 1000 individual data points for each ecosystem. The extensive data sets derived from the automated measurements allowed for the establishment of baseline data for each ecosystem, as well as for the recognition of daily variations and specific events that would most likely be missed (or miss-characterized) by infrequent sampling. In addition, the online FCM data from the river water was combined and correlated with online measurements of abiotic parameters, showing considerable potential for a better understanding of cause-and-effect relationships in aquatic ecosystems. Although several challenges remain, the successful operation of an automated online FCM system and the basic interpretation of the resulting data sets represent a breakthrough toward the eventual establishment of fully automated online microbiological monitoring technologies. PMID:24917858

  2. Automated Sensitivity Analysis of Interplanetary Trajectories for Optimal Mission Design

    NASA Technical Reports Server (NTRS)

    Knittel, Jeremy; Hughes, Kyle; Englander, Jacob; Sarli, Bruno

    2017-01-01

    This work describes a suite of Python tools known as the Python EMTG Automated Trade Study Application (PEATSA). PEATSA was written to automate the operation of trajectory optimization software, simplify the process of performing sensitivity analysis, and was ultimately found to out-perform a human trajectory designer in unexpected ways. These benefits will be discussed and demonstrated on sample mission designs.

  3. Practical interpretation of CYP2D6 haplotypes: Comparison and integration of automated and expert calling.

    PubMed

    Ruaño, Gualberto; Kocherla, Mohan; Graydon, James S; Holford, Theodore R; Makowski, Gregory S; Goethe, John W

    2016-05-01

    We describe a population genetic approach to compare samples interpreted with expert calling (EC) versus automated calling (AC) for CYP2D6 haplotyping. The analysis represents 4812 haplotype calls based on signal data generated by the Luminex xMap analyzers from 2406 patients referred to a high-complexity molecular diagnostics laboratory for CYP450 testing. DNA was extracted from buccal swabs. We compared the results of expert calls (EC) and automated calls (AC) with regard to haplotype number and frequency. The ratio of EC to AC was 1:3. Haplotype frequencies from EC and AC samples were convergent across haplotypes, and their distribution was not statistically different between the groups. Most duplications required EC, as only expansions with homozygous or hemizygous haplotypes could be automatedly called. High-complexity laboratories can offer equivalent interpretation to automated calling for non-expanded CYP2D6 loci, and superior interpretation for duplications. We have validated scientific expert calling specified by scoring rules as standard operating procedure integrated with an automated calling algorithm. The integration of EC with AC is a practical strategy for CYP2D6 clinical haplotyping. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Evaluation of automated sample preparation, retention time locked gas chromatography-mass spectrometry and data analysis methods for the metabolomic study of Arabidopsis species.

    PubMed

    Gu, Qun; David, Frank; Lynen, Frédéric; Rumpel, Klaus; Dugardeyn, Jasper; Van Der Straeten, Dominique; Xu, Guowang; Sandra, Pat

    2011-05-27

    In this paper, automated sample preparation, retention time locked gas chromatography-mass spectrometry (GC-MS) and data analysis methods for the metabolomics study were evaluated. A miniaturized and automated derivatisation method using sequential oximation and silylation was applied to a polar extract of 4 types (2 types×2 ages) of Arabidopsis thaliana, a popular model organism often used in plant sciences and genetics. Automation of the derivatisation process offers excellent repeatability, and the time between sample preparation and analysis was short and constant, reducing artifact formation. Retention time locked (RTL) gas chromatography-mass spectrometry was used, resulting in reproducible retention times and GC-MS profiles. Two approaches were used for data analysis. XCMS followed by principal component analysis (approach 1) and AMDIS deconvolution combined with a commercially available program (Mass Profiler Professional) followed by principal component analysis (approach 2) were compared. Several features that were up- or down-regulated in the different types were detected. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. 40Ar/39Ar dating of the eruptive history of Mount Erebus, Antarctica: Summit flows, tephra, and caldera collapse

    USGS Publications Warehouse

    Harpel, C.J.; Kyle, P.R.; Esser, R.P.; McIntosh, W.C.; Caldwell, D.A.

    2004-01-01

    Eruptive activity has occurred in the summit region of Mount Erebus over the last 95 ky, and has included numerous lava flows and small explosive eruptions, at least one plinian eruption, and at least one and probably two caldera-forming events. Furnace and laser step-heating 40Ar/39Ar ages have been determined for 16 summit lava flows and three englacial tephra layers erupted from Mount Erebus. The summit region is composed of at least one or possibly two superimposed calderas that have been filled by post-caldera lava flows ranging in age from 17 ?? 8 to 1 ?? 5 ka. Dated pre-caldera summit flows display two age populations at 95 ?? 9 to 76 ?? 4 ka and 27 ?? 3 to 21 ??4 ka of samples with tephriphonolite and phonolite compositions, respectively. A caldera-collapse event occurred between 25 and 11 ka. An older caldera-collapse event is likely to have occurred between 80 and 24 ka. Two englacial tephra layers from the flanks of Mount Erebus have been dated at 71 ?? 5 and 15 ?? 4 ka. These layers stratigraphically bracket 14 undated tephra layers, and predate 19 undated tephra layers, indicating that small-scale explosive activity has occurred throughout the late Pleistocene and Holocene eruptive history of Mount Erebus. A distal, englacial plinian-fall tephra sample has an age of 39 ?? 6 ka and may have been associated with the older of the two caldera-collapse events. A shift in magma composition from tephriphonolite to phonolite occurred at around 36 ka. ?? Springer-Verlag 2004.

  6. A low-cost acoustic permeameter

    NASA Astrophysics Data System (ADS)

    Drake, Stephen A.; Selker, John S.; Higgins, Chad W.

    2017-04-01

    Intrinsic permeability is an important parameter that regulates air exchange through porous media such as snow. Standard methods of measuring snow permeability are inconvenient to perform outdoors, are fraught with sampling errors, and require specialized equipment, while bringing intact samples back to the laboratory is also challenging. To address these issues, we designed, built, and tested a low-cost acoustic permeameter that allows computation of volume-averaged intrinsic permeability for a homogenous medium. In this paper, we validate acoustically derived permeability of homogenous, reticulated foam samples by comparison with results derived using a standard flow-through permeameter. Acoustic permeameter elements were designed for use in snow, but the measurement methods are not snow-specific. The electronic components - consisting of a signal generator, amplifier, speaker, microphone, and oscilloscope - are inexpensive and easily obtainable. The system is suitable for outdoor use when it is not precipitating, but the electrical components require protection from the elements in inclement weather. The permeameter can be operated with a microphone either internally mounted or buried a known depth in the medium. The calibration method depends on choice of microphone positioning. For an externally located microphone, calibration was based on a low-frequency approximation applied at 500 Hz that provided an estimate of both intrinsic permeability and tortuosity. The low-frequency approximation that we used is valid up to 2 kHz, but we chose 500 Hz because data reproducibility was maximized at this frequency. For an internally mounted microphone, calibration was based on attenuation at 50 Hz and returned only intrinsic permeability. We found that 50 Hz corresponded to a wavelength that minimized resonance frequencies in the acoustic tube and was also within the response limitations of the microphone. We used reticulated foam of known permeability (ranging from 2 × 10-7 to 3 × 10-9 m2) and estimated tortuosity of 1.05 to validate both methods. For the externally mounted microphone the mean normalized standard deviation was 6 % for permeability and 2 % for tortuosity. The mean relative error from known measurements was 17 % for permeability and 2 % for tortuosity. For the internally mounted microphone the mean normalized standard deviation for permeability was 10 % and the relative error was also 10 %. Permeability determination for an externally mounted microphone is less sensitive to environmental noise than is the internally mounted microphone and is therefore the recommended method. The approximation using the internally mounted microphone was developed as an alternative for circumstances in which placing the microphone in the medium was not feasible. Environmental noise degrades precision of both methods and is recognizable as increased scatter for replicate data points.

  7. Automated CD-SEM recipe creation technology for mass production using CAD data

    NASA Astrophysics Data System (ADS)

    Kawahara, Toshikazu; Yoshida, Masamichi; Tanaka, Masashi; Ido, Sanyu; Nakano, Hiroyuki; Adachi, Naokaka; Abe, Yuichi; Nagatomo, Wataru

    2011-03-01

    Critical Dimension Scanning Electron Microscope (CD-SEM) recipe creation needs sample preparation necessary for matching pattern registration, and recipe creation on CD-SEM using the sample, which hinders the reduction in test production cost and time in semiconductor manufacturing factories. From the perspective of cost reduction and improvement of the test production efficiency, automated CD-SEM recipe creation without the sample preparation and the manual operation has been important in the production lines. For the automated CD-SEM recipe creation, we have introduced RecipeDirector (RD) that enables the recipe creation by using Computer-Aided Design (CAD) data and text data that includes measurement information. We have developed a system that automatically creates the CAD data and the text data necessary for the recipe creation on RD; and, for the elimination of the manual operation, we have enhanced RD so that all measurement information can be specified in the text data. As a result, we have established an automated CD-SEM recipe creation system without the sample preparation and the manual operation. For the introduction of the CD-SEM recipe creation system using RD to the production lines, the accuracy of the pattern matching was an issue. The shape of design templates for the matching created from the CAD data was different from that of SEM images in vision. Thus, a development of robust pattern matching algorithm that considers the shape difference was needed. The addition of image processing of the templates for the matching and shape processing of the CAD patterns in the lower layer has enabled the robust pattern matching. This paper describes the automated CD-SEM recipe creation technology for the production lines without the sample preparation and the manual operation using RD applied in Sony Semiconductor Kyusyu Corporation Kumamoto Technology Center (SCK Corporation Kumamoto TEC).

  8. Robofurnace: A semi-automated laboratory chemical vapor deposition system for high-throughput nanomaterial synthesis and process discovery

    PubMed Central

    Oliver, C. Ryan; Westrick, William; Koehler, Jeremy; Brieland-Shoultz, Anna; Anagnostopoulos-Politis, Ilias; Cruz-Gonzalez, Tizoc; Hart, A. John

    2013-01-01

    Laboratory research and development on new materials, such as nanostructured thin films, often utilizes manual equipment such as tube furnaces due to its relatively low cost and ease of setup. However, these systems can be prone to inconsistent outcomes due to variations in standard operating procedures and limitations in performance such as heating and cooling rates restrict the parameter space that can be explored. Perhaps more importantly, maximization of research throughput and the successful and efficient translation of materials processing knowledge to production-scale systems, relies on the attainment of consistent outcomes. In response to this need, we present a semi-automated lab-scale chemical vapor deposition (CVD) furnace system, called “Robofurnace.” Robofurnace is an automated CVD system built around a standard tube furnace, which automates sample insertion and removal and uses motion of the furnace to achieve rapid heating and cooling. The system has a 10-sample magazine and motorized transfer arm, which isolates the samples from the lab atmosphere and enables highly repeatable placement of the sample within the tube. The system is designed to enable continuous operation of the CVD reactor, with asynchronous loading/unloading of samples. To demonstrate its performance, Robofurnace is used to develop a rapid CVD recipe for carbon nanotube (CNT) forest growth, achieving a 10-fold improvement in CNT forest mass density compared to a benchmark recipe using a manual tube furnace. In the long run, multiple systems like Robofurnace may be linked to share data among laboratories by methods such as Twitter. Our hope is Robofurnace and like automation will enable machine learning to optimize and discover relationships in complex material synthesis processes. PMID:24289435

  9. A pneumatic device for rapid loading of DNA sequencing gels.

    PubMed

    Panussis, D A; Cook, M W; Rifkin, L L; Snider, J E; Strong, J T; McGrane, R M; Wilson, R K; Mardis, E R

    1998-05-01

    This work describes the design and construction of a device that facilitates the loading of DNA samples onto polyacrylamide gels for detection in the Perkin Elmer/Applied Biosystems (PE/ABI) 373 and 377 DNA sequencing instruments. The device is mounted onto the existing gel cassettes and makes the process of loading high-density gels less cumbersome while the associated time and errors are reduced. The principle of operation includes the simultaneous transfer of the entire batch of samples, in which a spring-loaded air cylinder generates positive pressure and flexible silica capillaries transfer the samples. A retractable capillary array carrier allows the delivery ends of the capillaries to be held up clear of the gel during loader attachment on the gel plates, while enabling their insertion in the gel wells once the device is securely mounted. Gel-loading devices capable of simultaneously transferring 72 samples onto the PE/ABI 373 and 377 are currently being used in our production sequencing groups while a 96-sample transfer prototype undergoes testing.

  10. Cutaway line drawing of STS-34 middeck experiment Polymer Morphology (PM)

    NASA Technical Reports Server (NTRS)

    1989-01-01

    Cutaway line drawing shows components of STS-34 middeck experiment Polymer Morphology (PM). Generic Electronics Module (GEM) components include the control housing, circulating fans, hard disk, tape drives, computer boards, and heat exchanger. PM, a 3M-developed organic materials processing experiment, is designed to explore the effects of microgravity on polymeric materials as they are processed in space. The samples of polymeric materials being studied in the PM experiment are thin films (25 microns or less) approximately 25mm in diameter. The samples are mounted between two infrared transparent windows in a specially designed infrared cell that provides the capability of thermally processing the samples to 200 degrees Celsius with a high degree of thermal control. The samples are mounted on a carousel that allows them to be positioned, one at a time, in the infrared beam where spectra may be acquired. The GEM provides all carousel and sample cell control (SCC). The first flight of P

  11. Real-time exhaust gas modular flowmeter and emissions reporting system for mobile apparatus

    NASA Technical Reports Server (NTRS)

    Breton, Leo Alphonse Gerard (Inventor)

    2002-01-01

    A real-time emissions reporting system includes an instrument module adapted to be detachably connected to the exhaust pipe of a combustion engine to provide for flow of exhaust gas therethrough. The instrument module includes a differential pressure probe which allows for determination of flow rate of the exhaust gas and a gas sampling tube for continuously feeding a sample of the exhaust gas to a gas analyzer or a mounting location for a non-sampling gas analyzer. In addition to the module, the emissions reporting system also includes an elastomeric boot for detachably connecting the module to the exhaust pipe of the combustion engine, a gas analyzer for receiving and analyzing gases sampled within the module and a computer for calculating pollutant mass flow rates based on concentrations detected by the gas analyzer and the detected flowrate of the exhaust gas. The system may also include a particulate matter detector with a second gas sampling tube feeding same mounted within the instrument module.

  12. Measuring Evapotranspiration in Urban Irrigated Lawns in Two Kansas Cities

    NASA Astrophysics Data System (ADS)

    Shonkwiler, K. B.; Bremer, D.; Ham, J. M.

    2011-12-01

    Conservation of water is becoming increasingly critical in many metropolitan areas. The use of automated irrigation systems for the maintenance of lawns and landscapes is rising and these systems are typically maladjusted to apply more water than necessary, resulting in water wastage. Provision of accurate estimates of actual lawn water use may assist urbanites in conserving water through better adjustment of automatic irrigation systems. Micrometeorological methods may help determine actual lawn water use by measuring evapotranspiration (ET) from urban lawns. From April - August of 2011, four small tripod-mounted weather stations (tripods, five total) were deployed in twelve residential landscapes in the Kansas cities of Manhattan (MHK) and Wichita (ICT) in the USA (six properties in each city). Each tripod was instrumented to estimate reference crop evapotranspiration (ETo) via the FAO-56 method. During tripod deployment in residential lawns, actual evapotranspiration (ETactual) was measured nearby using a stationary, trailer-mounted eddy covariance (EC) station. The EC station sampled well-watered turf at the K-State Rocky Ford Turfgrass Center within 5 km of the study properties in MHK, and was also deployed at a commercial sod farm 15 - 40 km from the study residences in the greater ICT metro area. The fifth tripod was deployed in the source area of the EC station to estimate ETo in conjunction with tripods in the lawns (i.e., to serve as a reference). Data from EC allowed for computation of a so-called lawn coefficient (Kc) by determining the ratio of ETo from the tripods in residential lawns to ETo from the EC station (ETo,EC); hence, Kc = ETo,tripod / ETo,EC. Using this method, ETactual can be estimated for individual tripods within a lawn. Data suggests that it may be more accurate to quantify ET within individual lawns by microclimate (i.e., determine coefficients for "shaded" and "open/unshaded" portions of a lawn). By finding microclimate coefficients, estimates of ETactual for individual lawns can be tailored to the specific characteristics of each property.

  13. Non-Uniform Sampling and J-UNIO Automation for Efficient Protein NMR Structure Determination.

    PubMed

    Didenko, Tatiana; Proudfoot, Andrew; Dutta, Samit Kumar; Serrano, Pedro; Wüthrich, Kurt

    2015-08-24

    High-resolution structure determination of small proteins in solution is one of the big assets of NMR spectroscopy in structural biology. Improvements in the efficiency of NMR structure determination by advances in NMR experiments and automation of data handling therefore attracts continued interest. Here, non-uniform sampling (NUS) of 3D heteronuclear-resolved [(1)H,(1)H]-NOESY data yielded two- to three-fold savings of instrument time for structure determinations of soluble proteins. With the 152-residue protein NP_372339.1 from Staphylococcus aureus and the 71-residue protein NP_346341.1 from Streptococcus pneumonia we show that high-quality structures can be obtained with NUS NMR data, which are equally well amenable to robust automated analysis as the corresponding uniformly sampled data. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Automated diagnostic kiosk for diagnosing diseases

    DOEpatents

    Regan, John Frederick; Birch, James Michael

    2014-02-11

    An automated and autonomous diagnostic apparatus that is capable of dispensing collection vials and collections kits to users interesting in collecting a biological sample and submitting their collected sample contained within a collection vial into the apparatus for automated diagnostic services. The user communicates with the apparatus through a touch-screen monitor. A user is able to enter personnel information into the apparatus including medical history, insurance information, co-payment, and answer a series of questions regarding their illness, which is used to determine the assay most likely to yield a positive result. Remotely-located physicians can communicate with users of the apparatus using video tele-medicine and request specific assays to be performed. The apparatus archives submitted samples for additional testing. Users may receive their assay results electronically. Users may allow the uploading of their diagnoses into a central databank for disease surveillance purposes.

  15. MOUNT JEFFERSON PRIMITIVE AREA, OREGON.

    USGS Publications Warehouse

    Walker, George W.; Pattee, Eldon C.

    1984-01-01

    Mineral and reconnaissance geothermal surveys of the Mount Jefferson Primitive Area in the Cascade Range of Oregon indicate little likelihood that metallic or nonmetallic mineral or energy resources exist in the area. Several mining claims, presumably located for gold, are present, but analyses of samples from the claims failed to detect the presence of gold or other valuable metals. Rock for construction purposes is abundantly present, but better and more accessible deposits are available in adjacent areas.

  16. Deployable Aeroshell Flexible Thermal Protection System Testing

    NASA Technical Reports Server (NTRS)

    Hughes, Stephen J.; Ware, Joanne S.; DelCorso, Joseph A.; Lugo, Rafael A.

    2009-01-01

    Deployable aeroshells offer the promise of achieving larger aeroshell surface areas for entry vehicles than otherwise attainable without deployment. With the larger surface area comes the ability to decelerate high-mass entry vehicles at relatively low ballistic coefficients. However, for an aeroshell to perform even at the low ballistic coefficients attainable with deployable aeroshells, a flexible thermal protection system (TPS) is required that is capable of surviving reasonably high heat flux and durable enough to survive the rigors of construction handling, high density packing, deployment, aerodynamic loading and aerothermal heating. The Program for the Advancement of Inflatable Decelerators for Atmospheric Entry (PAIDAE) is tasked with developing the technologies required to increase the technology readiness level (TRL) of inflatable deployable aeroshells, and one of several of the technologies PAIDAE is developing for use on inflatable aeroshells is flexible TPS. Several flexible TPS layups were designed, based on commercially available materials, and tested in NASA Langley Research Center's 8 Foot High Temperature Tunnel (8ft HTT). The TPS layups were designed for, and tested at three different conditions that are representative of conditions seen in entry simulation analyses of inflatable aeroshell concepts. Two conditions were produced in a single run with a sting-mounted dual wedge test fixture. The dual wedge test fixture had one row of sample mounting locations (forward) at about half the running length of the top surface of the wedge. At about two thirds of the running length of the wedge, a second test surface drafted up at five degrees relative to the first test surface established the remaining running length of the wedge test fixture. A second row of sample mounting locations (aft) was positioned in the middle of the running length of the second test surface. Once the desired flow conditions were established in the test section the dual wedge test fixture, oriented at 5 degrees angle of attack down, was injected into the flow. In this configuration the aft sample mounting location was subjected to roughly twice the heat flux and surface pressure of the forward mounting location. The tunnel was run at two different conditions for the test series: 1) 'Low Pressure', and 2) 'High Pressure'. At 'Low Pressure' conditions the TPS layups were tested at 6W/cm2 and 11W/cm2 while at 'High Pressure' conditions the TPS layups were tested at 11W/cm2 and 20W/cm2. This paper details the test configuration of the TPS samples in the 8Ft HTT, the sample holder assembly, TPS sample layup construction, sample instrumentation, results from this testing, as well as lessons learned.

  17. Peripheral refractive correction and automated perimetric profiles.

    PubMed

    Wild, J M; Wood, J M; Crews, S J

    1988-06-01

    The effect of peripheral refractive error correction on the automated perimetric sensitivity profile was investigated on a sample of 10 clinically normal, experienced observers. Peripheral refractive error was determined at eccentricities of 0 degree, 20 degrees and 40 degrees along the temporal meridian of the right eye using the Canon Autoref R-1, an infra-red automated refractor, under the parametric conditions of the Octopus automated perimeter. Perimetric sensitivity was then undertaken at these eccentricities (stimulus sizes 0 and III) with and without the appropriate peripheral refractive correction using the Octopus 201 automated perimeter. Within the measurement limits of the experimental procedures employed, perimetric sensitivity was not influenced by peripheral refractive correction.

  18. Optical See-Through Head Mounted Display Direct Linear Transformation Calibration Robustness in the Presence of User Alignment Noise

    NASA Technical Reports Server (NTRS)

    Axholt, Magnus; Skoglund, Martin; Peterson, Stephen D.; Cooper, Matthew D.; Schoen, Thomas B.; Gustafsson, Fredrik; Ynnerman, Anders; Ellis, Stephen R.

    2010-01-01

    Augmented Reality (AR) is a technique by which computer generated signals synthesize impressions that are made to coexist with the surrounding real world as perceived by the user. Human smell, taste, touch and hearing can all be augmented, but most commonly AR refers to the human vision being overlaid with information otherwise not readily available to the user. A correct calibration is important on an application level, ensuring that e.g. data labels are presented at correct locations, but also on a system level to enable display techniques such as stereoscopy to function properly [SOURCE]. Thus, vital to AR, calibration methodology is an important research area. While great achievements already have been made, there are some properties in current calibration methods for augmenting vision which do not translate from its traditional use in automated cameras calibration to its use with a human operator. This paper uses a Monte Carlo simulation of a standard direct linear transformation camera calibration to investigate how user introduced head orientation noise affects the parameter estimation during a calibration procedure of an optical see-through head mounted display.

  19. Three-dimensional visualization and display technologies; Proceedings of the Meeting, Los Angeles, CA, Jan. 18-20, 1989

    NASA Technical Reports Server (NTRS)

    Robbins, Woodrow E. (Editor); Fisher, Scott S. (Editor)

    1989-01-01

    Special attention was given to problems of stereoscopic display devices, such as CAD for enhancement of the design process in visual arts, stereo-TV improvement of remote manipulator performance, a voice-controlled stereographic video camera system, and head-mounted displays and their low-cost design alternatives. Also discussed was a novel approach to chromostereoscopic microscopy, computer-generated barrier-strip autostereography and lenticular stereograms, and parallax barrier three-dimensional TV. Additional topics include processing and user interface isssues and visualization applications, including automated analysis and fliud flow topology, optical tomographic measusrements of mixing fluids, visualization of complex data, visualization environments, and visualization management systems.

  20. Oak ridge national laboratory automated clean chemistry for bulk analysis of environmental swipe samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bostick, Debra A.; Hexel, Cole R.; Ticknor, Brian W.

    2016-11-01

    To shorten the lengthy and costly manual chemical purification procedures, sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment. This addresses a serious need in the nuclear safeguards community to debottleneck the separation of U and Pu in environmental samples—currently performed by overburdened chemists—with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc., the prepFAST-MC2 was designed based on current COTS equipment that was modified for U/Pu separations utilizing Eichrom™ TEVA and UTEVA resins. Initial verification of individual columns yielded small elution volumes with consistent elution profiles and good recovery. Combined columnmore » calibration demonstrated ample separation without crosscontamination of the eluent. Automated packing and unpacking of the built-in columns initially showed >15% deviation in resin loading by weight, which can lead to inconsistent separations. Optimization of the packing and unpacking methods led to a reduction in the variability of the packed resin to less than 5% daily. The reproducibility of the automated system was tested with samples containing 30 ng U and 15 pg Pu, which were separated in a series with alternating reagent blanks. These experiments showed very good washout of both the resin and the sample from the columns as evidenced by low blank values. Analysis of the major and minor isotope ratios for U and Pu provided values well within data quality limits for the International Atomic Energy Agency. Additionally, system process blanks spiked with 233U and 244Pu tracers were separated using the automated system after it was moved outside of a clean room and yielded levels equivalent to clean room blanks, confirming that the system can produce high quality results without the need for expensive clean room infrastructure. Comparison of the amount of personnel time necessary for successful manual vs. automated chemical separations showed a significant decrease in hands-on time from 9.8 hours to 35 minutes for seven samples, respectively. This documented time savings and reduced labor translates to a significant cost savings per sample. Overall, the system will enable faster sample reporting times at reduced costs by limiting personnel hours dedicated to the chemical separation.« less

  1. Biofilm monitoring coupon system and method of use

    NASA Technical Reports Server (NTRS)

    Sauer, Richard L. (Inventor); Flanagan, David T. (Inventor)

    1991-01-01

    An apparatus and method is disclosed for biofilm monitoring of a water distribution system which includes the mounting of at least one fitting in a wall port of a manifold in the water distribution system with a passage through the fitting in communication. The insertion of a biofilm sampling member is through the fitting with planar sampling surfaces of different surface treatment provided on linearly arrayed sample coupons of the sampling member disposed in the flow stream in edge-on parallel relation to the direction of the flow stream of the manifold under fluid-tight sealed conditions. The sampling member is adapted to be aseptically removed from or inserted in the fitting and manifold under a positive pressure condition and the fitting passage sealed immediately thereafter by appropriate closure means so as to preclude contamination of the water distribution system through the fitting. The apparatus includes means for clamping the sampling member and for establishing electrical continuity between the sampling surfaces and the system for minimizing electropotential effects. The apparatus may also include a plurality of fittings and sampling members mounted on the manifold to permit extraction of the sampling members in a timed sequence throughout the monitoring period.

  2. Thermal expansion behavior of LDEF metal matrix composites

    NASA Technical Reports Server (NTRS)

    Le, T. D.; Steckel, G. L.

    1992-01-01

    The effects of the space environment on the thermal expansion stability of metal matrix composites (graphite/Al and graphite/Mg) will be presented. A sample from each category of metal matrix composites mounted on the leading and trailing edge was chosen for analysis of the temperature-time-thermal strain histories. Typical thermal expansion curves over the same range of temperature were selected at the beginning, mid, and end of the recording duration. The thermal expansion of selected post-flight LDEF samples were measured over the same range of temperature in the laboratory using a Michelson laser interferometer. The thermal strains were monitored concurrently with a laser interferometer and a mounted strain gage.

  3. Detection of immunomagnetically captured 4',6-diamidino-2-phenyl-indole (DAPI)-labeled Escherichia coli 0157:H7 by fluorescent microscopic imaging

    NASA Astrophysics Data System (ADS)

    Tu, Shu-I.; Uknalis, Joseph; Patterson, Deidre; Gehring, Andrew G.

    1999-01-01

    Live cells of E. coliO157:H7 were captured by goat anti-E. coliO157 serum coated on the surface of polystyrene based immunomagnetic beads (IMB). The captured bacteria were labeled by 4',6-diamidino-2-phenylindole (DAPI), a nucleic acid stain, for observation by epifluorescent microscopy. The beads with captured bacteria were then concentrated by magnetic separators. The efficiency of this magnetic concentration step was less than that of using high speed centrifugation. The antibody-captured and IMB-immobilized bacteria were then applied on HF-treated, bovine serum albumin (BSA)-coated microscope slides mounted on an automated stage, and magnetically aligned before fluorescence distribution was measured by a cooled CCD attached to an inverted microscope. Since the beads were concentrated and linearly aligned along the edge of the magnetic field, image capture along the edge for a few field widths was sufficient to account for most of captured bacteria. We applied this approach to determine the bacterial counts in spiked beef hamburger patties. The results showed that after a 6-hour enrichment, sufficient number of the bacteria could be detected from the samples spiked with 1 CFU of E. coliO157:H7 per gram of the hamburger.

  4. Contamination analyses of technology mirror assembly optical surfaces

    NASA Technical Reports Server (NTRS)

    Germani, Mark S.

    1991-01-01

    Automated electron microprobe analyses were performed on tape lift samples from the Technology Mirror Assembly (TMA) optical surfaces. Details of the analyses are given, and the contamination of the mirror surfaces is discussed. Based on the automated analyses of the tape lifts from the TMA surfaces and the control blank, we can conclude that the particles identified on the actual samples were not a result of contamination due to the handling or sampling process itself and that the particles reflect the actual contamination on the surface of the mirror.

  5. Human mixed lymphocyte cultures. Evaluation of microculture technique utilizing the multiple automated sample harvester (MASH)

    PubMed Central

    Thurman, G. B.; Strong, D. M.; Ahmed, A.; Green, S. S.; Sell, K. W.; Hartzman, R. J.; Bach, F. H.

    1973-01-01

    Use of lymphocyte cultures for in vitro studies such as pretransplant histocompatibility testing has established the need for standardization of this technique. A microculture technique has been developed that has facilitated the culturing of lymphocytes and increased the quantity of cultures feasible, while lowering the variation between replicate samples. Cultures were prepared for determination of tritiated thymidine incorporation using a Multiple Automated Sample Harvester (MASH). Using this system, the parameters that influence the in vitro responsiveness of human lymphocytes to allogeneic lymphocytes have been investigated. PMID:4271568

  6. Diagnosis and molecular characterization of Trichomonas vaginalis in sex workers in the Philippines

    PubMed Central

    Queza, Macario Ireneo P; Rivera, Windell L

    2013-01-01

    Trichomonas vaginalis is a pathogenic protozoon which causes the sexually transmitted infection, trichomoniasis. The absence or non-specificity of symptoms often leads to misdiagnosis of the infection. In this study, 969 samples consisting of vaginal swabs and urine were collected and screened from social hygiene clinics across the Philippines. Of the 969 samples, 216 were used for the comparative analysis of diagnostic tools such as wet mount microscopy, culture, and PCR utilizing universal trichomonad primers, TFR1/2 and species-specific primers, TVK3/7 and TV1/2. PCR demonstrated higher sensitivity of 100% compared to 77% of the wet mount. PCR primer set TVK3/7 and culture had the same and the best expected average performance [receiver-operating characteristic (ROC): 0.98]. Prevalence of infection in the sample population was 6.8%. PMID:23683368

  7. Trace element and Pb isotope composition of plagioclase from dome samples from the 2004-2005 eruption of Mount St. Helens, Washington: Chapter 35 in A volcano rekindled: the renewed eruption of Mount St. Helens, 2004-2006

    USGS Publications Warehouse

    Kent, Adam J.R.; Rowe, Michael C.; Thornber, Carl R.; Pallister, John S.; Sherrod, David R.; Scott, William E.; Stauffer, Peter H.

    2008-01-01

    Plagioclase crystals from gabbronorite inclusions in three dacite samples have markedly different trace-element and Pbisotope compositions from those of plagioclase phenocrysts, despite having a similar range of anorthite contents. Inclusions show some systematic differences from each other but typically have higher Ti, Ba, LREE, and Pb and lower Sr and have lower 208Pb/206Pb and 207Pb/206Pb ratios than coexisting plagioclase phenocrysts. The compositions of plagioclase from inclusions cannot be related to phenocryst compositions by any reasonable petrologic model. From this we suggest that they are unlikely to represent magmatic cumulates or restite inclusions but instead are samples of mafic Tertiary basement from beneath the volcano.

  8. The Automation-by-Expertise-by-Training Interaction.

    PubMed

    Strauch, Barry

    2017-03-01

    I introduce the automation-by-expertise-by-training interaction in automated systems and discuss its influence on operator performance. Transportation accidents that, across a 30-year interval demonstrated identical automation-related operator errors, suggest a need to reexamine traditional views of automation. I review accident investigation reports, regulator studies, and literature on human computer interaction, expertise, and training and discuss how failing to attend to the interaction of automation, expertise level, and training has enabled operators to commit identical automation-related errors. Automated systems continue to provide capabilities exceeding operators' need for effective system operation and provide interfaces that can hinder, rather than enhance, operator automation-related situation awareness. Because of limitations in time and resources, training programs do not provide operators the expertise needed to effectively operate these automated systems, requiring them to obtain the expertise ad hoc during system operations. As a result, many do not acquire necessary automation-related system expertise. Integrating automation with expected operator expertise levels, and within training programs that provide operators the necessary automation expertise, can reduce opportunities for automation-related operator errors. Research to address the automation-by-expertise-by-training interaction is needed. However, such research must meet challenges inherent to examining realistic sociotechnical system automation features with representative samples of operators, perhaps by using observational and ethnographic research. Research in this domain should improve the integration of design and training and, it is hoped, enhance operator performance.

  9. Automated processing of forensic casework samples using robotic workstations equipped with nondisposable tips: contamination prevention.

    PubMed

    Frégeau, Chantal J; Lett, C Marc; Elliott, Jim; Yensen, Craig; Fourney, Ron M

    2008-05-01

    An automated process has been developed for the analysis of forensic casework samples using TECAN Genesis RSP 150/8 or Freedom EVO liquid handling workstations equipped exclusively with nondisposable tips. Robot tip cleaning routines have been incorporated strategically within the DNA extraction process as well as at the end of each session. Alternative options were examined for cleaning the tips and different strategies were employed to verify cross-contamination. A 2% sodium hypochlorite wash (1/5th dilution of the 10.8% commercial bleach stock) proved to be the best overall approach for preventing cross-contamination of samples processed using our automated protocol. The bleach wash steps do not adversely impact the short tandem repeat (STR) profiles developed from DNA extracted robotically and allow for major cost savings through the implementation of fixed tips. We have demonstrated that robotic workstations equipped with fixed pipette tips can be used with confidence with properly designed tip washing routines to process casework samples using an adapted magnetic bead extraction protocol.

  10. UV LED lighting for automated crystal centring

    PubMed Central

    Chavas, Leonard M. G.; Yamada, Yusuke; Hiraki, Masahiko; Igarashi, Noriyuki; Matsugaki, Naohiro; Wakatsuki, Soichi

    2011-01-01

    A direct outcome of the exponential growth of macromolecular crystallography is the continuously increasing demand for synchrotron beam time, both from academic and industrial users. As more and more projects entail screening a profusion of sample crystals, fully automated procedures at every level of the experiments are being implemented at all synchrotron facilities. One of the major obstacles to achieving such automation lies in the sample recognition and centring in the X-ray beam. The capacity of UV light to specifically react with aromatic residues present in proteins or with DNA base pairs is at the basis of UV-assisted crystal centring. Although very efficient, a well known side effect of illuminating biological samples with strong UV sources is the damage induced on the irradiated samples. In the present study the effectiveness of a softer UV light for crystal centring by taking advantage of low-power light-emitting diode (LED) sources has been investigated. The use of UV LEDs represents a low-cost solution for crystal centring with high specificity. PMID:21169682

  11. Automated methods for multiplexed pathogen detection.

    PubMed

    Straub, Timothy M; Dockendorff, Brian P; Quiñonez-Díaz, Maria D; Valdez, Catherine O; Shutthanandan, Janani I; Tarasevich, Barbara J; Grate, Jay W; Bruckner-Lea, Cynthia J

    2005-09-01

    Detection of pathogenic microorganisms in environmental samples is a difficult process. Concentration of the organisms of interest also co-concentrates inhibitors of many end-point detection methods, notably, nucleic acid methods. In addition, sensitive, highly multiplexed pathogen detection continues to be problematic. The primary function of the BEADS (Biodetection Enabling Analyte Delivery System) platform is the automated concentration and purification of target analytes from interfering substances, often present in these samples, via a renewable surface column. In one version of BEADS, automated immunomagnetic separation (IMS) is used to separate cells from their samples. Captured cells are transferred to a flow-through thermal cycler where PCR, using labeled primers, is performed. PCR products are then detected by hybridization to a DNA suspension array. In another version of BEADS, cell lysis is performed, and community RNA is purified and directly labeled. Multiplexed detection is accomplished by direct hybridization of the RNA to a planar microarray. The integrated IMS/PCR version of BEADS can successfully purify and amplify 10 E. coli O157:H7 cells from river water samples. Multiplexed PCR assays for the simultaneous detection of E. coli O157:H7, Salmonella, and Shigella on bead suspension arrays was demonstrated for the detection of as few as 100 cells for each organism. Results for the RNA version of BEADS are also showing promising results. Automation yields highly purified RNA, suitable for multiplexed detection on microarrays, with microarray detection specificity equivalent to PCR. Both versions of the BEADS platform show great promise for automated pathogen detection from environmental samples. Highly multiplexed pathogen detection using PCR continues to be problematic, but may be required for trace detection in large volume samples. The RNA approach solves the issues of highly multiplexed PCR and provides "live vs. dead" capabilities. However, sensitivity of the method will need to be improved for RNA analysis to replace PCR.

  12. Automated Methods for Multiplexed Pathogen Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Straub, Tim M.; Dockendorff, Brian P.; Quinonez-Diaz, Maria D.

    2005-09-01

    Detection of pathogenic microorganisms in environmental samples is a difficult process. Concentration of the organisms of interest also co-concentrates inhibitors of many end-point detection methods, notably, nucleic acid methods. In addition, sensitive, highly multiplexed pathogen detection continues to be problematic. The primary function of the BEADS (Biodetection Enabling Analyte Delivery System) platform is the automated concentration and purification of target analytes from interfering substances, often present in these samples, via a renewable surface column. In one version of BEADS, automated immunomagnetic separation (IMS) is used to separate cells from their samples. Captured cells are transferred to a flow-through thermal cyclermore » where PCR, using labeled primers, is performed. PCR products are then detected by hybridization to a DNA suspension array. In another version of BEADS, cell lysis is performed, and community RNA is purified and directly labeled. Multiplexed detection is accomplished by direct hybridization of the RNA to a planar microarray. The integrated IMS/PCR version of BEADS can successfully purify and amplify 10 E. coli O157:H7 cells from river water samples. Multiplexed PCR assays for the simultaneous detection of E. coli O157:H7, Salmonella, and Shigella on bead suspension arrays was demonstrated for the detection of as few as 100 cells for each organism. Results for the RNA version of BEADS are also showing promising results. Automation yields highly purified RNA, suitable for multiplexed detection on microarrays, with microarray detection specificity equivalent to PCR. Both versions of the BEADS platform show great promise for automated pathogen detection from environmental samples. Highly multiplexed pathogen detection using PCR continues to be problematic, but may be required for trace detection in large volume samples. The RNA approach solves the issues of highly multiplexed PCR and provides ''live vs. dead'' capabilities. However, sensitivity of the method will need to be improved for RNA analysis to replace PCR.« less

  13. Evaluation of cell count and classification capabilities in body fluids using a fully automated Sysmex XN equipped with high-sensitive Analysis (hsA) mode and DI-60 hematology analyzer system.

    PubMed

    Takemura, Hiroyuki; Ai, Tomohiko; Kimura, Konobu; Nagasaka, Kaori; Takahashi, Toshihiro; Tsuchiya, Koji; Yang, Haeun; Konishi, Aya; Uchihashi, Kinya; Horii, Takashi; Tabe, Yoko; Ohsaka, Akimichi

    2018-01-01

    The XN series automated hematology analyzer has been equipped with a body fluid (BF) mode to count and differentiate leukocytes in BF samples including cerebrospinal fluid (CSF). However, its diagnostic accuracy is not reliable for CSF samples with low cell concentration at the border between normal and pathologic level. To overcome this limitation, a new flow cytometry-based technology, termed "high sensitive analysis (hsA) mode," has been developed. In addition, the XN series analyzer has been equipped with the automated digital cell imaging analyzer DI-60 to classify cell morphology including normal leukocytes differential and abnormal malignant cells detection. Using various BF samples, we evaluated the performance of the XN-hsA mode and DI-60 compared to manual microscopic examination. The reproducibility of the XN-hsA mode showed good results in samples with low cell densities (coefficient of variation; % CV: 7.8% for 6 cells/μL). The linearity of the XN-hsA mode was established up to 938 cells/μL. The cell number obtained using the XN-hsA mode correlated highly with the corresponding microscopic examination. Good correlation was also observed between the DI-60 analyses and manual microscopic classification for all leukocyte types, except monocytes. In conclusion, the combined use of cell counting with the XN-hsA mode and automated morphological analyses using the DI-60 mode is potentially useful for the automated analysis of BF cells.

  14. An experimental setup for the simultaneous measurement of thermoelectric power of two samples from 77 K to 500 K.

    PubMed

    Tripathi, T S; Bala, M; Asokan, K

    2014-08-01

    We report on an experimental setup for the simultaneous measurement of the thermoelectric power (TEP) of two samples in the temperature range from 77 K to 500 K using optimum electronic instruments. The setup consists of two rectangular copper bars in a bridge arrangement for sample mounting, two surface mount (SM) chip resistors for creating alternate temperature gradient, and a type E thermocouple in differential geometry for gradient temperature (ΔT) measurement across the samples. In addition, a diode arrangement has been made for the alternate heating of SM resistors using only one DC current source. The measurement accuracy of ΔT increases with the differential thermocouple arrangement. For the calibration of the setup, measurements of TEP on a high purity (99.99%) platinum wire and type K thermocouple wires Chromel and Alumel have been performed from 77 K to 500 K with respect to copper lead wires. Additionally, this setup can be utilized to calibrate an unknown sample against a sample of known absolute TEP.

  15. An experimental setup for the simultaneous measurement of thermoelectric power of two samples from 77 K to 500 K

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tripathi, T. S.; Bala, M.; Asokan, K.

    2014-08-01

    We report on an experimental setup for the simultaneous measurement of the thermoelectric power (TEP) of two samples in the temperature range from 77 K to 500 K using optimum electronic instruments. The setup consists of two rectangular copper bars in a bridge arrangement for sample mounting, two surface mount (SM) chip resistors for creating alternate temperature gradient, and a type E thermocouple in differential geometry for gradient temperature (ΔT) measurement across the samples. In addition, a diode arrangement has been made for the alternate heating of SM resistors using only one DC current source. The measurement accuracy of ΔTmore » increases with the differential thermocouple arrangement. For the calibration of the setup, measurements of TEP on a high purity (99.99%) platinum wire and type K thermocouple wires Chromel and Alumel have been performed from 77 K to 500 K with respect to copper lead wires. Additionally, this setup can be utilized to calibrate an unknown sample against a sample of known absolute TEP.« less

  16. AN AUTOMATED MONITORING SYSTEM FOR FISH PHYSIOLOGY AND TOXICOLOGY

    EPA Science Inventory

    This report describes a data acquisition and control (DAC) system that was constructed to manage selected physiological measurements and sample control for aquatic physiology and toxicology. Automated DAC was accomplished with a microcomputer running menu-driven software develope...

  17. MAVARIC - a comparison of automation-assisted and manual cervical screening: a randomised controlled trial.

    PubMed

    Kitchener, H C; Blanks, R; Cubie, H; Desai, M; Dunn, G; Legood, R; Gray, A; Sadique, Z; Moss, S

    2011-01-01

    The principal objective was to compare automation-assisted reading of cervical cytology with manual reading using the histological end point of cervical intraepithelial neoplasia grade II (CIN2) or worse (CIN2+). Secondary objectives included (i) an assessment of the slide ranking facility of the Becton Dickinson (BD) FocalPoint™ Slide Profiler (Becton Dickinson, Franklin Lakes, NJ, USA), especially 'No Further Review', (ii) a comparison of the two approved automated systems, the ThinPrep® Imaging System (Hologic, Bedford, MA, USA) and the BD FocalPoint Guided Screener Imaging System, and (iii) automated versus manual in terms of productivity and cost-effectiveness. A 1 : 2 randomised allocation of slides to either manual reading or automation-assisted paired with manual reading. Cytoscreeners were blinded to whether samples would be read only manually or manually paired with automated. Slide reading procedures followed real-life laboratory protocol to produce a final result and, for paired readings, the worse result determined the management. Costs per event were estimated and combined with productivity to produce a cost per slide, per woman and per CIN2+ and cervical intraepithelial neoplasia grade III (CIN3) or worse (CIN3+) lesion detected. Cost-effectiveness was estimated using cost per CIN2+ detected. Lifetime cost-effectiveness in terms of life-years and quality-adjusted life-years was estimated using a mathematical model. Liquid-based cytology samples were obtained in primary care, and a small number of abnormal samples were obtained from local colposcopy clinics, from different women, in order to enrich the proportion of abnormals. All of the samples were read in a single large service laboratory. Liquid residues used for human papillomavirus (HPV) triage were tested (with Hybrid Capture 2, Qiagen, Crawley, UK) in a specialist virology laboratory in Edinburgh, UK. Histopathology was read by a specialist gynaecological pathology team blinded to HPV results and type of reading. Samples were obtained from women aged 25-64 years undergoing primary cervical screening in Greater Manchester, UK, with small proportions from women outside this age range and from women undergoing colposcopy. The principal intervention was automation-assisted reading of cervical cytology slides which was paired with a manual reading of the same slide. Low-grade cytological abnormalities (borderline and mild dyskaryosis) were triaged with HPV testing to direct colposcopy referral. Women with high-grade cytology were referred for colposcopy and those with negative cytology were returned to recall. The principal outcome measure was the sensitivity of automation-assisted reading relative to manual for the detection of CIN2+. A secondary outcome measure was cost-effectiveness of each type of reading to detect CIN2+. The study was powered to detect a relative sensitivity difference equivalent to an absolute difference of 5%. The principal finding was that automated reading was 8% less sensitive relative to manual, 6.3% in absolute terms. 'No further review' was very reliable and, if restricted to routine screening samples, < 1% of CIN2+ would have been missed. Automated and manual were very similar in terms of cost-effectiveness despite a 60%-80% increase in productivity for automation-assisted reading. The significantly reduced sensitivity of automated reading, combined with uncertainty over cost-effectiveness, suggests no justification at present to recommend its introduction. The reliability of 'no further review' warrants further consideration as a means of saving staff time. Current Controlled Trials ISRCTN66377374. This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 15, No. 3. See the HTA programme website for further project information.

  18. Isotopic Insights Into the Degassing and Secondary Hydration Rates of Volcanic Glass From the 1980 Eruptions of Mount St. Helens

    NASA Astrophysics Data System (ADS)

    Seligman, A. N.; Bindeman, I. N.; Van Eaton, A. R.; Hoblitt, R. P.

    2016-12-01

    Following eruption, volcanic glass undergoes hydration in its depositional environment, which overprints the history of magmatic degassing recorded in the glass. However, the rates of secondary hydration of volcanic glass used for paleoclimate studies are poorly constrained. Here, we present our results of a natural experiment using products of the 1980 eruptions of Mount St. Helens. We measured the δD of extracted water and the δ18O of the bulk glass of samples collected during the dry summer months of 1980 and compared them with material resampled in August of 2015. Results demonstrate that only samples collected from the subsurface near gas escape pipes show elevated water concentrationss (near 2.0 wt.%) and low δD (-110 to -130 ‰) and δ18O (6.0 to 6.6 ‰) values, and that the initial process of secondary hydration is not always a simple addition of low δD waters at ambient temperature. On average, the 2015 surface samples have slightly higher water contents (0.1-0.2 wt.%) and similar δ18O (6.8 - 6.9 ‰) to those collected in 1980. Given the moderate vesicularity of the samples and the slow rate of surface temperature diffusion, we attribute these observations to hydration during cooling, with only little exchange after. We also compare our results to rapidly quenched air fall pumice from the May 18th eruption, which shows moderate δD values (-74 ‰) and water concentrations (0.3 wt.%) that are closer to those for the 1980 samples. Surprisingly, the 2015 surface samples show higher δD values (+15 ‰), which we attribute to any of four possibilities: (1) evaporation or (2) degassing of underlying deposits; (3) exchange of hydrogen with local vegetation; and/or (4) microlite crystallization that aided diffusion of water. Reconstructed δD-H2O trends for the Mount St. Helens samples collected in 1980 support previous studies proposing that exsolved volatiles were trapped within a rapidly rising magma that degassed at shallow depths. The dacitic Mount St. Helens (with rhyolitic groundmass) trend overlaps with crystal-poor rhyolitic eruptions studied previously, suggesting similar behavior of volatiles upon exsolution.

  19. A METHOD FOR AUTOMATED ANALYSIS OF 10 ML WATER SAMPLES CONTAINING ACIDIC, BASIC, AND NEUTRAL SEMIVOLATILE COMPOUNDS LISTED IN USEPA METHOD 8270 BY SOLID PHASE EXTRACTION COUPLED IN-LINE TO LARGE VOLUME INJECTION GAS CHROMATOGRAPHY/MASS SPECTROMETRY

    EPA Science Inventory

    Data is presented showing the progress made towards the development of a new automated system combining solid phase extraction (SPE) with gas chromatography/mass spectrometry for the single run analysis of water samples containing a broad range of acid, base and neutral compounds...

  20. Appendix C: Automated Vitrification of Mammalian Embryos on a Digital Microfluidic Device.

    PubMed

    Liu, Jun; Pyne, Derek G; Abdelgawad, Mohamed; Sun, Yu

    2017-01-01

    This chapter introduces a digital microfluidic device that automates sample preparation for mammalian embryo vitrification. Individual microdroplets manipulated on the microfluidic device were used as microvessels to transport a single mouse embryo through a complete vitrification procedure. Advantages of this approach, compared to manual operation and channel-based microfluidic vitrification, include automated operation, cryoprotectant concentration gradient generation, and feasibility of loading and retrieval of embryos.

  1. A Liquid-Handling Robot for Automated Attachment of Biomolecules to Microbeads.

    PubMed

    Enten, Aaron; Yang, Yujia; Ye, Zihan; Chu, Ryan; Van, Tam; Rothschild, Ben; Gonzalez, Francisco; Sulchek, Todd

    2016-08-01

    Diagnostics, drug delivery, and other biomedical industries rely on cross-linking ligands to microbead surfaces. Microbead functionalization requires multiple steps of liquid exchange, incubation, and mixing, which are laborious and time intensive. Although automated systems exist, they are expensive and cumbersome, limiting their routine use in biomedical laboratories. We present a small, bench-top robotic system that automates microparticle functionalization and streamlines sample preparation. The robot uses a programmable microcontroller to regulate liquid exchange, incubation, and mixing functions. Filters with a pore diameter smaller than the minimum bead diameter are used to prevent bead loss during liquid exchange. The robot uses three liquid reagents and processes up to 10(7) microbeads per batch. The effectiveness of microbead functionalization was compared with a manual covalent coupling process and evaluated via flow cytometry and fluorescent imaging. The mean percentages of successfully functionalized beads were 91% and 92% for the robot and manual methods, respectively, with less than 5% bead loss. Although the two methods share similar qualities, the automated approach required approximately 10 min of active labor, compared with 3 h for the manual approach. These results suggest that a low-cost, automated microbead functionalization system can streamline sample preparation with minimal operator intervention. © 2015 Society for Laboratory Automation and Screening.

  2. Automated sample-changing robot for solution scattering experiments at the EMBL Hamburg SAXS station X33

    PubMed Central

    Round, A. R.; Franke, D.; Moritz, S.; Huchler, R.; Fritsche, M.; Malthan, D.; Klaering, R.; Svergun, D. I.; Roessle, M.

    2008-01-01

    There is a rapidly increasing interest in the use of synchrotron small-angle X-ray scattering (SAXS) for large-scale studies of biological macromolecules in solution, and this requires an adequate means of automating the experiment. A prototype has been developed of an automated sample changer for solution SAXS, where the solutions are kept in thermostatically controlled well plates allowing for operation with up to 192 samples. The measuring protocol involves controlled loading of protein solutions and matching buffers, followed by cleaning and drying of the cell between measurements. The system was installed and tested at the X33 beamline of the EMBL, at the storage ring DORIS-III (DESY, Hamburg), where it was used by over 50 external groups during 2007. At X33, a throughput of approximately 12 samples per hour, with a failure rate of sample loading of less than 0.5%, was observed. The feedback from users indicates that the ease of use and reliability of the user operation at the beamline were greatly improved compared with the manual filling mode. The changer is controlled by a client–server-based network protocol, locally and remotely. During the testing phase, the changer was operated in an attended mode to assess its reliability and convenience. Full integration with the beamline control software, allowing for automated data collection of all samples loaded into the machine with remote control from the user, is presently being implemented. The approach reported is not limited to synchrotron-based SAXS but can also be used on laboratory and neutron sources. PMID:25484841

  3. Development of a simple indocyanine green measurement method using an automated biochemical analyser.

    PubMed

    Sato, Yuka; Seimiya, Masanori; Yoshida, Toshihiko; Sawabe, Yuji; Hokazono, Eisaku; Osawa, Susumu; Matsushita, Kazuyuki

    2017-01-01

    Background The indocyanine green retention rate is important for assessing the severity of liver disorders. In the conventional method, blood needs to be collected twice. In the present study, we developed an automated indocyanine green method that does not require blood sampling before intravenous indocyanine green injections and is applicable to an automated biochemical analyser. Methods The serum samples of 471 patients collected before and after intravenous indocyanine green injections and submitted to the clinical laboratory of our hospital were used as samples. The standard procedure established by the Japan Society of Hepatology was used as the standard method. In the automated indocyanine green method, serum collected after an intravenous indocyanine green injection was mixed with the saline reagent containing a surfactant, and the indocyanine green concentration was measured at a dominant wavelength of 805 nm and a complementary wavelength of 884 nm. Results The coefficient of variations of the within- and between-run reproducibilities of this method were 2% or lower, and dilution linearity passing the origin was noted up to 10 mg/L indocyanine green. The reagent was stable for four weeks or longer. Haemoglobin, bilirubin and chyle had no impact on the results obtained. The correlation coefficient between the standard method (x) and this method (y) was r=0.995; however, slight divergence was noted in turbid samples. Conclusion Divergence in turbid samples may have corresponded to false negativity with the standard procedure. Our method may be highly practical because blood sampling before indocyanine green loading is unnecessary and measurements are simple.

  4. Decision Making In A High-Tech World: Automation Bias and Countermeasures

    NASA Technical Reports Server (NTRS)

    Mosier, Kathleen L.; Skitka, Linda J.; Burdick, Mark R.; Heers, Susan T.; Rosekind, Mark R. (Technical Monitor)

    1996-01-01

    Automated decision aids and decision support systems have become essential tools in many high-tech environments. In aviation, for example, flight management systems computers not only fly the aircraft, but also calculate fuel efficient paths, detect and diagnose system malfunctions and abnormalities, and recommend or carry out decisions. Air Traffic Controllers will soon be utilizing decision support tools to help them predict and detect potential conflicts and to generate clearances. Other fields as disparate as nuclear power plants and medical diagnostics are similarly becoming more and more automated. Ideally, the combination of human decision maker and automated decision aid should result in a high-performing team, maximizing the advantages of additional cognitive and observational power in the decision-making process. In reality, however, the presence of these aids often short-circuits the way that even very experienced decision makers have traditionally handled tasks and made decisions, and introduces opportunities for new decision heuristics and biases. Results of recent research investigating the use of automated aids have indicated the presence of automation bias, that is, errors made when decision makers rely on automated cues as a heuristic replacement for vigilant information seeking and processing. Automation commission errors, i.e., errors made when decision makers inappropriately follow an automated directive, or automation omission errors, i.e., errors made when humans fail to take action or notice a problem because an automated aid fails to inform them, can result from this tendency. Evidence of the tendency to make automation-related omission and commission errors has been found in pilot self reports, in studies using pilots in flight simulations, and in non-flight decision making contexts with student samples. Considerable research has found that increasing social accountability can successfully ameliorate a broad array of cognitive biases and resultant errors. To what extent these effects generalize to performance situations is not yet empirically established. The two studies to be presented represent concurrent efforts, with student and professional pilot samples, to determine the effects of accountability pressures on automation bias and on the verification of the accurate functioning of automated aids. Students (Experiment 1) and commercial pilots (Experiment 2) performed simulated flight tasks using automated aids. In both studies, participants who perceived themselves as accountable for their strategies of interaction with the automation were significantly more likely to verify its correctness, and committed significantly fewer automation-related errors than those who did not report this perception.

  5. Using Satellite Data to Characterize the Temporal Thermal Behavior of an Active Volcano: Mount St. Helens, WA

    NASA Technical Reports Server (NTRS)

    Vaughan, R. Greg; Hook, Simon J.

    2006-01-01

    ASTER thermal infrared data over Mt. St Helens were used to characterize its thermal behavior from Jun 2000 to Feb 2006. Prior to the Oct 2004 eruption, the average crater temperature varied seasonally between -12 and 6 C. After the eruption, maximum single-pixel temperature increased from 10 C (Oct 2004) to 96 C (Aug 2005), then showed a decrease to Feb 2006. The initial increase in temperature was correlated with dome morphology and growth rate and the subsequent decrease was interpreted to relate to both seasonal trends and a decreased growth rate/increased cooling rate, possibly suggesting a significant change in the volcanic system. A single-pixel ASTER thermal anomaly first appeared on Oct 1, 2004, eleven hours after the first eruption - 10 days before new lava was exposed at the surface. By contrast, an automated algorithm for detecting thermal anomalies in MODIS data did not trigger an alert until Dec 18. However, a single-pixel thermal anomaly first appeared in MODIS channel 23 (4 um) on Oct 13, 12 days after the first eruption - 2 days after lava was exposed. The earlier thermal anomaly detected with ASTER data is attributed to the higher spatial resolution (90 m) compared with MODIS (1 m) and the earlier visual observation of anomalous pixels compared to the automated detection method suggests that local spatial statistics and background radiance data could improve automated detection methods.

  6. Changes to Serum Sample Tube and Processing Methodology Does Not Cause Inter-Individual Variation in Automated Whole Serum N-Glycan Profiling in Health and Disease

    PubMed Central

    Shubhakar, Archana; Kalla, Rahul; Nimmo, Elaine R.; Fernandes, Daryl L.; Satsangi, Jack; Spencer, Daniel I. R.

    2015-01-01

    Introduction Serum N-glycans have been identified as putative biomarkers for numerous diseases. The impact of different serum sample tubes and processing methods on N-glycan analysis has received relatively little attention. This study aimed to determine the effect of different sample tubes and processing methods on the whole serum N-glycan profile in both health and disease. A secondary objective was to describe a robot automated N-glycan release, labeling and cleanup process for use in a biomarker discovery system. Methods 25 patients with active and quiescent inflammatory bowel disease and controls had three different serum sample tubes taken at the same draw. Two different processing methods were used for three types of tube (with and without gel-separation medium). Samples were randomised and processed in a blinded fashion. Whole serum N-glycan release, 2-aminobenzamide labeling and cleanup was automated using a Hamilton Microlab STARlet Liquid Handling robot. Samples were analysed using a hydrophilic interaction liquid chromatography/ethylene bridged hybrid(BEH) column on an ultra-high performance liquid chromatography instrument. Data were analysed quantitatively by pairwise correlation and hierarchical clustering using the area under each chromatogram peak. Qualitatively, a blinded assessor attempted to match chromatograms to each individual. Results There was small intra-individual variation in serum N-glycan profiles from samples collected using different sample processing methods. Intra-individual correlation coefficients were between 0.99 and 1. Unsupervised hierarchical clustering and principal coordinate analyses accurately matched samples from the same individual. Qualitative analysis demonstrated good chromatogram overlay and a blinded assessor was able to accurately match individuals based on chromatogram profile, regardless of disease status. Conclusions The three different serum sample tubes processed using the described methods cause minimal inter-individual variation in serum whole N-glycan profile when processed using an automated workstream. This has important implications for N-glycan biomarker discovery studies using different serum processing standard operating procedures. PMID:25831126

  7. Changes to serum sample tube and processing methodology does not cause Intra-Individual [corrected] variation in automated whole serum N-glycan profiling in health and disease.

    PubMed

    Ventham, Nicholas T; Gardner, Richard A; Kennedy, Nicholas A; Shubhakar, Archana; Kalla, Rahul; Nimmo, Elaine R; Fernandes, Daryl L; Satsangi, Jack; Spencer, Daniel I R

    2015-01-01

    Serum N-glycans have been identified as putative biomarkers for numerous diseases. The impact of different serum sample tubes and processing methods on N-glycan analysis has received relatively little attention. This study aimed to determine the effect of different sample tubes and processing methods on the whole serum N-glycan profile in both health and disease. A secondary objective was to describe a robot automated N-glycan release, labeling and cleanup process for use in a biomarker discovery system. 25 patients with active and quiescent inflammatory bowel disease and controls had three different serum sample tubes taken at the same draw. Two different processing methods were used for three types of tube (with and without gel-separation medium). Samples were randomised and processed in a blinded fashion. Whole serum N-glycan release, 2-aminobenzamide labeling and cleanup was automated using a Hamilton Microlab STARlet Liquid Handling robot. Samples were analysed using a hydrophilic interaction liquid chromatography/ethylene bridged hybrid(BEH) column on an ultra-high performance liquid chromatography instrument. Data were analysed quantitatively by pairwise correlation and hierarchical clustering using the area under each chromatogram peak. Qualitatively, a blinded assessor attempted to match chromatograms to each individual. There was small intra-individual variation in serum N-glycan profiles from samples collected using different sample processing methods. Intra-individual correlation coefficients were between 0.99 and 1. Unsupervised hierarchical clustering and principal coordinate analyses accurately matched samples from the same individual. Qualitative analysis demonstrated good chromatogram overlay and a blinded assessor was able to accurately match individuals based on chromatogram profile, regardless of disease status. The three different serum sample tubes processed using the described methods cause minimal inter-individual variation in serum whole N-glycan profile when processed using an automated workstream. This has important implications for N-glycan biomarker discovery studies using different serum processing standard operating procedures.

  8. Detection of Respiratory Viruses in Sputum from Adults by Use of Automated Multiplex PCR

    PubMed Central

    Walsh, Edward E.; Formica, Maria A.; Falsey, Ann R.

    2014-01-01

    Respiratory tract infections (RTI) frequently cause hospital admissions among adults. Diagnostic viral reverse transcriptase PCR (RT-PCR) of nose and throat swabs (NTS) is useful for patient care by informing antiviral use and appropriate isolation. However, automated RT-PCR systems are not amenable to utilizing sputum due to its viscosity. We evaluated a simple method of processing sputum samples in a fully automated respiratory viral panel RT-PCR assay (FilmArray). Archived sputum and NTS samples collected in 2008-2012 from hospitalized adults with RTI were evaluated. A subset of sputum samples positive for 10 common viruses by a uniplex RT-PCR was selected. A sterile cotton-tip swab was dunked in sputum, swirled in 700 μL of sterile water (dunk and swirl method) and tested by the FilmArray assay. Quantitative RT-PCR was performed on “dunked” sputum and NTS samples for influenza A (Flu A), respiratory syncytial virus (RSV), coronavirus OC43 (OC43), and human metapneumovirus (HMPV). Viruses were identified in 31% of 965 illnesses using a uniplex RT-PCR. The sputum sample was the only sample positive for 105 subjects, including 35% (22/64) of influenza cases and significantly increased the diagnostic yield of NTS alone (302/965 [31%] versus 197/965 [20%]; P = 0.0001). Of 108 sputum samples evaluated by the FilmArray assay using the dunk and swirl method, 99 (92%) were positive. Quantitative RT-PCR revealed higher mean viral loads in dunked sputum samples compared to NTS samples for Flu A, RSV, and HMPV (P = 0.0001, P = 0.006, and P = 0.011, respectively). The dunk and swirl method is a simple and practical method for reliably processing sputum samples in a fully automated PCR system. The higher viral loads in sputa may increase detection over NTS testing alone. PMID:25056335

  9. Automated Extraction of Formalin-Fixed, Paraffin-Embedded Tissue for High-Risk Human Papillomavirus Testing of Head and Neck Squamous Cell Carcinomas Using the Roche Cobas 4800 System.

    PubMed

    Kerr, Darcy A; Sweeney, Brenda; Arpin, Ronald N; Ring, Melissa; Pitman, Martha B; Wilbur, David C; Faquin, William C

    2016-08-01

    -Testing for high-risk human papillomavirus (HR-HPV) in head and neck squamous cell carcinomas (HNSCCs) is important for both prognostication and clinical management. Several testing platforms are available for HR-HPV; however, effective alternative automated approaches are needed. -To assess the performance of the automated Roche cobas 4800 HPV real-time polymerase chain reaction-based system on formalin-fixed, paraffin-embedded HNSCC specimens and compare results with standard methods of in situ hybridization (ISH) and p16 immunohistochemistry. -Formalin-fixed, paraffin-embedded samples of HNSCC were collected from archival specimens in the Department of Pathology, Massachusetts General Hospital (Boston), and prepared using the automated system by deparaffinization and dehydration followed by tissue lysis. Samples were integrated into routine cervical cytology testing runs by cobas. Corresponding formalin-fixed, paraffin-embedded samples were evaluated for HR-HPV by ISH and p16 by immunohistochemistry. Discrepant cases were adjudicated by polymerase chain reaction. -Sixty-two HNSCC samples were analyzed using the automated cobas system, ISH, and immunohistochemistry. Fifty-two percent (n = 32 of 62) of formalin-fixed, paraffin-embedded tumors were positive for HR-HPV by cobas. Eighty-eight percent (n = 28 of 32) of cases were the HPV 16 subtype and 12% (n = 4 of 32) were other HR-HPV subtypes. Corresponding testing with ISH was concordant in 92% (n = 57 of 62) of cases. Compared with the adjudication polymerase chain reaction standard, there were 3 false-positive cases by cobas. -Concordance in HNSCC HR-HPV status between cobas and ISH was more than 90%. The cobas demonstrated a sensitivity of 100% and a specificity of 91% for detection of HR-HPV. Advantages favoring cobas include its automation, cost efficiency, objective results, and ease of performance.

  10. Immunochemistry for high-throughput screening of human exhaled breath condensate (EBC) media: implementation of automated Quanterix SIMOA instrumentation.

    PubMed

    Pleil, Joachim D; Angrish, Michelle M; Madden, Michael C

    2015-12-11

    Immunochemistry is an important clinical tool for indicating biological pathways leading towards disease. Standard enzyme-linked immunosorbent assays (ELISA) are labor intensive and lack sensitivity at low-level concentrations. Here we report on emerging technology implementing fully-automated ELISA capable of molecular level detection and describe application to exhaled breath condensate (EBC) samples. The Quanterix SIMOA HD-1 analyzer was evaluated for analytical performance for inflammatory cytokines (IL-6, TNF-α, IL-1β and IL-8). The system was challenged with human EBC representing the most dilute and analytically difficult of the biological media. Calibrations from synthetic samples and spiked EBC showed excellent linearity at trace levels (r(2)  >  0.99). Sensitivities varied by analyte, but were robust from ~0.006 (IL-6) to ~0.01 (TNF-α) pg ml(-1). All analytes demonstrated response suppression when diluted with deionized water and so assay buffer diluent was found to be a better choice. Analytical runs required ~45 min setup time for loading samples, reagents, calibrants, etc., after which the instrument performs without further intervention for up to 288 separate samples. Currently, available kits are limited to single-plex analyses and so sample volumes require adjustments. Sample dilutions should be made with assay diluent to avoid response suppression. Automation performs seamlessly and data are automatically analyzed and reported in spreadsheet format. The internal 5-parameter logistic (pl) calibration model should be supplemented with a linear regression spline at the very lowest analyte levels, (<1.3 pg ml(-1)). The implementation of the automated Quanterix platform was successfully demonstrated using EBC, which poses the greatest challenge to ELISA due to limited sample volumes and low protein levels.

  11. The stability and validity of automated vocal analysis in preverbal preschoolers with autism spectrum disorder.

    PubMed

    Woynaroski, Tiffany; Oller, D Kimbrough; Keceli-Kaysili, Bahar; Xu, Dongxin; Richards, Jeffrey A; Gilkerson, Jill; Gray, Sharmistha; Yoder, Paul

    2017-03-01

    Theory and research suggest that vocal development predicts "useful speech" in preschoolers with autism spectrum disorder (ASD), but conventional methods for measurement of vocal development are costly and time consuming. This longitudinal correlational study examines the reliability and validity of several automated indices of vocalization development relative to an index derived from human coded, conventional communication samples in a sample of preverbal preschoolers with ASD. Automated indices of vocal development were derived using software that is presently "in development" and/or only available for research purposes and using commercially available Language ENvironment Analysis (LENA) software. Indices of vocal development that could be derived using the software available for research purposes: (a) were highly stable with a single day-long audio recording, (b) predicted future spoken vocabulary to a degree that was nonsignificantly different from the index derived from conventional communication samples, and (c) continued to predict future spoken vocabulary even after controlling for concurrent vocabulary in our sample. The score derived from standard LENA software was similarly stable, but was not significantly correlated with future spoken vocabulary. Findings suggest that automated vocal analysis is a valid and reliable alternative to time intensive and expensive conventional communication samples for measurement of vocal development of preverbal preschoolers with ASD in research and clinical practice. Autism Res 2017, 10: 508-519. © 2016 International Society for Autism Research, Wiley Periodicals, Inc. © 2016 International Society for Autism Research, Wiley Periodicals, Inc.

  12. Detection of Obstacles in Monocular Image Sequences

    NASA Technical Reports Server (NTRS)

    Kasturi, Rangachar; Camps, Octavia

    1997-01-01

    The ability to detect and locate runways/taxiways and obstacles in images captured using on-board sensors is an essential first step in the automation of low-altitude flight, landing, takeoff, and taxiing phase of aircraft navigation. Automation of these functions under different weather and lighting situations, can be facilitated by using sensors of different modalities. An aircraft-based Synthetic Vision System (SVS), with sensors of different modalities mounted on-board, complements the current ground-based systems in functions such as detection and prevention of potential runway collisions, airport surface navigation, and landing and takeoff in all weather conditions. In this report, we address the problem of detection of objects in monocular image sequences obtained from two types of sensors, a Passive Millimeter Wave (PMMW) sensor and a video camera mounted on-board a landing aircraft. Since the sensors differ in their spatial resolution, and the quality of the images obtained using these sensors is not the same, different approaches are used for detecting obstacles depending on the sensor type. These approaches are described separately in two parts of this report. The goal of the first part of the report is to develop a method for detecting runways/taxiways and objects on the runway in a sequence of images obtained from a moving PMMW sensor. Since the sensor resolution is low and the image quality is very poor, we propose a model-based approach for detecting runways/taxiways. We use the approximate runway model and the position information of the camera provided by the Global Positioning System (GPS) to define regions of interest in the image plane to search for the image features corresponding to the runway markers. Once the runway region is identified, we use histogram-based thresholding to detect obstacles on the runway and regions outside the runway. This algorithm is tested using image sequences simulated from a single real PMMW image.

  13. Automation of flow injection gas diffusion-ion chromatography for the nanomolar determination of methylamines and ammonia in seawater and atmospheric samples

    PubMed Central

    Gibb, Stuart W.; Wood, John W.; Fauzi, R.; Mantoura, C.

    1995-01-01

    The automation and improved design and performance of Flow Injection Gas Diffusion-Ion Chromatography (FIGD-IC), a novel technique for the simultaneous analysis of trace ammonia (NH3) and methylamines (MAs) in aqueous media, is presented. Automated Flow Injection Gas Diffusion (FIGD) promotes the selective transmembrane diffusion of MAs and NH3 from aqueous sample under strongly alkaline (pH > 12, NaOH), chelated (EDTA) conditions into a recycled acidic acceptor stream. The acceptor is then injected onto an ion chromatograph where NH3 and the MAs are fully resolved as their cations and detected conductimetrically. A versatile PC interfaced control unit and data capture unit (DCU) are employed in series to direct the selonoid valve switching sequence, IC operation and collection of data. Automation, together with other modifications improved both linearily (R2 > 0.99 MAs 0-100 nM, NH3 0-1000 nM) and precision (<8%) of FIGD-IC at nanomolar concentrations, compared with the manual procedure. The system was successfully applied to the determination of MAs and NH3 in seawater and in trapped particulate and gaseous atmospheric samples during an oceanographic research cruise. PMID:18925047

  14. Automated agar plate streaker: a linear plater on Society for Biomolecular Sciences standard plates.

    PubMed

    King, Gregory W; Kath, Gary S; Siciliano, Sal; Simpson, Neal; Masurekar, Prakash; Sigmund, Jan; Polishook, Jon; Skwish, Stephen; Bills, Gerald; Genilloud, Olga; Peláez, Fernando; Martín, Jesus; Dufresne, Claude

    2006-09-01

    Several protocols for bacterial isolation and techniques for aerobic plate counting rely on the use of a spiral plater to deposit concentration gradients of microbial suspensions onto a circular agar plate to isolate colony growth. The advantage of applying a gradient of concentrations across the agar surface is that the original microbiological sample can be applied at a single concentration rather than as multiple serial dilutions. The spiral plater gradually dilutes the sample across a compact area and therefore saves time preparing dilutions and multiple agar plates. Commercial spiral platers are not automated and require manual sample loading. Dispensing of the sample volume and rate of gradients are often very limited in range. Furthermore, the spiral sample application cannot be used with rectangular microplates. Another limitation of commercial spiral platers is that they are useful only for dilute, filtered suspensions and cannot plate suspensions of coarse organic particles therefore precluding the use of many kinds of microorganism-containing substrata. An automated agar plate spreader capable of processing 99 rectangular microplates in unattended mode is described. This novel instrument is capable of dispensing discrete volumes of sample in a linear pattern. It can be programmed to dispense a sample suspense at a uniform application rate or across a decreasing concentration gradient.

  15. Mount Saint Helens aerosol evolution

    NASA Technical Reports Server (NTRS)

    Oberbeck, V. R.; Farlow, N. H.; Snetsinger, K. G.; Ferry, G. V.; Fong, W.; Hayes, D. M.

    1982-01-01

    Stratospheric aerosol samples were collected using a wire impactor during the year following the eruption of Mt. St. Helens. Analysis of samples shows that aerosol volume increased for 6 months due to gas-to-particle conversion and then decreased to background levels in the following 6 months.

  16. Undergraduate Electron-Spin-Resonance Experiment.

    ERIC Educational Resources Information Center

    Willis, James S.

    1980-01-01

    Describes the basic procedures for use of an electron-spin resonance spectrometer and potassium azide (KN3) in an experiment which extends from the phase of sample preparation (crystal growth, sample mounting, and orientation) through data taking to the stages of calculation and theoretical explanation. (Author/DS)

  17. Improved format for radiocardiographic data

    NASA Technical Reports Server (NTRS)

    Dimeff, J.; Sevelius, G.

    1973-01-01

    Technique involves introduction of radioactive sample into antecubital vein. Scintillation crystal mounted in collimating housing views portion of right and left hearts. As radioactive sample passes through heart, counting rate is measured by crystal and recorded on strip chart. Data is insensitive to geometric effects and other parameters.

  18. 238U-230Th-226Ra disequilibria in dacite and plagioclase from the 2004-2005 eruption of Mount St. Helens: Chapter 36 in A volcano rekindled: the renewed eruption of Mount St. Helens, 2004-2006

    USGS Publications Warehouse

    Cooper, Kari M.; Donnelly, Carrie T.; Sherrod, David R.; Scott, William E.; Stauffer, Peter H.

    2008-01-01

    230Th)/(232Th) measured for the 1980s reference suite. However, (230Th)/(232Th) for plagioclase separates for dome samples erupted during October and November 2004 are significantly different from corresponding whole-rock values, which suggests that a large fraction (>30 percent) of crystals in each sample are foreign to the host liquid. Furthermore, plagioclase in the two 2004 samples have U-series characteristics distinct from each other and from plagioclase in dacite erupted in 1982, indicating that (1) the current eruption must include a component of crystals (and potentially associated magma) that were not sampled by the 1980-86 eruption, and (2) dacite magmas erupted only a month apart in 2004 contain different populations of crystals, indicating that this foreign component is highly heterogeneous within the 2004-5 magma reservoir.

  19. Key Locations Studied at 'Pahrump Hills' on Mars

    NASA Image and Video Library

    2017-06-09

    NASA's Curiosity Mars rover examined a mudstone outcrop area called "Pahrump Hills" on lower Mount Sharp, in 2014 and 2015. This view shows locations of some targets the rover studied there. The blue dots indicate where drilled samples of powdered rock were collected for analysis. The rover drilled a sample of rock powder at "Confidence Hills" in September 2014 and analyzed it with internal laboratory instruments. Then the mission conducted a walkabout survey up the slope, along the route indicated in yellow, stopping for close inspection at the red-dot locations. Observations from the walkabout were used to choose where to take additional drilled samples for analysis during a second pass up the slope. The "Mojave 2" sample was collected in January 2015 and the "Telegraph Peak" one in February 2015. This view of the outcrop and other portions of Mount Sharp beyond is a mosaic of images taken by the rover's Mast Camera (Mastcam) in September 2014. https://photojournal.jpl.nasa.gov/catalog/PIA21709

  20. Opportunistic Parasites among Immunosuppressed Children in Minia District, Egypt

    PubMed Central

    Ahmad, Azza K.; Ali, Basma A.; Moslam, Fadia A.

    2012-01-01

    A total of 450 stool samples were collected from inpatient and outpatient clinics of Pediatric Department, Minia University Hospital, Minia District, Egypt. Two groups of patients were studied, including 200 immunosuppressed and 250 immunocompetent children. Stool samples were subjected to wet saline and iodine mounts. A concentration technique (formol-ether sedimentation method) was carried out for stool samples diagnosed negative by wet saline and iodine mounts. Samples were stained by 2 different methods; acid fast stain (modified Ziehl-Neelsen stain) and Giemsa stain. Total 188 cases (94%) were diagnosed positive for parasitic infections among immunosuppressed children, whereas 150 cases (60%) were positive in immunocompetent children (P<0.0001). The most common protozoan infection in immunosuppressed group was Cryptosporidium parvum (60.2%), followed by Blastocystis hominis (12.1%), Isospora belli (9.7%), and Cyclospora caytenensis (7.8%). On the other hand, Entamoeba histolytica (24.6%) and Giardia lamblia (17.6%) were more common than other protozoans in immunocompetent children. PMID:22451735

  1. Rotorcraft Aeromechanics Branch Home Page on the World Wide Web

    NASA Technical Reports Server (NTRS)

    Peterson, Randall L.; Warmbrodt, William (Technical Monitor)

    1996-01-01

    The tilt rotor aircraft holds great promise for improving air travel in the future. It's benefits include vertical take off and landing combined with airspeeds comparable to propeller driven aircraft. However, the noise from a tilt rotor during approach to a landing is potentially a significant barrier to widespread acceptance of these aircraft. This approach noise is primarily caused by Blade Vortex Interactions (BVI), which are created when the blade passes near or through the vortex trailed by preceding blades. The XV- 15 Aeroacoustic test will measure the noise from a tilt rotor during descent conditions and demonstrate several possible techniques to reduce the noise. The XV- 15 Aeroacoustic test at NASA Ames Research Center will measure acoustics and performance for a full-scale XV-15 rotor. A single XV-15 rotor will be mounted on the Ames Rotor Test Apparatus (RTA) in the 80- by 120-Foot Wind Tunnel. The test will be conducted in helicopter mode with forward flight speeds up to 100 knots and tip path plane angles up to +/- 15 degrees. These operating conditions correspond to a wide range of tilt rotor descent and transition to forward flight cases. Rotor performance measurements will be made with the RTA rotor balance, while acoustic measurements will be made using an acoustic traverse and four fixed microphones. The acoustic traverse will provide limited directionality measurements on the advancing side of the rotor, where BVI noise is expected to be the highest. Baseline acoustics and performance measurements for the three-bladed rotor will be obtained over the entire test envelope. Acoustic measurements will also be obtained for correlation with the XV-15 aircraft Inflight Rotor Aeroacoustic Program (IRAP) recently conducted by Ames. Several techniques will be studied in an attempt to reduce the highest measured BVI noise conditions. The first of these techniques will use sub-wings mounted on the blade tips. These subwings are expected to alter the size, strength, and location of the tip vortex, therefore changing the BVI acoustics of the rotor. The subwings are approximately 20% of the blade chord and increase the rotor radius by about 3 percent. Four different subwing configurations will be tested, including square tipped subwings with different angles of incidence. The ability of active controls to reduce BVI acoustics will also be assessed. The dynamic control system of the RTA will be used to implement open- and closed-loop active control techniques, including individual blade control. Open-loop testing will be conducted using a personal computer based, automated, real-time data acquisition system. This system features combined automated output of open loop control signals and automated data acquisition of the resulting test data. A final technique to alter the noise of the rotor will be examined. This will involve changing the number of blades from three to four. A four-bladed rotor hub has been fabricated on which the XV-15 blades will be mounted. While the solidity of the rotor will increase, much useful information can be gained by examining the changes in the thrust and RPM with four blades.

  2. MULTI-COLOR OPTICAL AND NEAR-INFRARED LIGHT CURVES OF 64 STRIPPED-ENVELOPE CORE-COLLAPSE SUPERNOVAE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bianco, F. B.; Modjaz, M.; Hicken, M.

    2014-08-01

    We present a densely sampled, homogeneous set of light curves of 64 low-redshift (z ≲ 0.05) stripped-envelope supernovae (SNe of Type IIb, Ib, Ic, and Ic-BL). These data were obtained between 2001 and 2009 at the Fred L. Whipple Observatory (FLWO) on Mount Hopkins in Arizona, with the optical FLWO 1.2 m and the near-infrared (NIR) Peters Automated Infrared 1.3 m telescopes. Our data set consists of 4543 optical photometric measurements on 61 SNe, including a combination of U BV RI, U BV r{sup ′}i{sup ′}, and u{sup ′} BV r{sup ′}i{sup ′}, and 1919 JHK{sub s} NIR measurements onmore » 25 SNe. This sample constitutes the most extensive multi-color data set of stripped-envelope SNe to date. Our photometry is based on template-subtracted images to eliminate any potential host-galaxy light contamination. This work presents these photometric data, compares them with data in the literature, and estimates basic statistical quantities: date of maximum, color, and photometric properties. We identify promising color trends that may permit the identification of stripped-envelope SN subtypes from their photometry alone. Many of these SNe were observed spectroscopically by the Harvard-Smithsonian Center for Astrophysics (CfA) SN group, and the spectra are presented in a companion paper. A thorough exploration that combines the CfA photometry and spectroscopy of stripped-envelope core-collapse SNe will be presented in a follow-up paper.« less

  3. Ram-air sample collection device for a chemical warfare agent sensor

    DOEpatents

    Megerle, Clifford A.; Adkins, Douglas R.; Frye-Mason, Gregory C.

    2002-01-01

    In a surface acoustic wave sensor mounted within a body, the sensor having a surface acoustic wave array detector and a micro-fabricated sample preconcentrator exposed on a surface of the body, an apparatus for collecting air for the sensor, comprising a housing operatively arranged to mount atop the body, the housing including a multi-stage channel having an inlet and an outlet, the channel having a first stage having a first height and width proximate the inlet, a second stage having a second lower height and width proximate the micro-fabricated sample preconcentrator, a third stage having a still lower third height and width proximate the surface acoustic wave array detector, and a fourth stage having a fourth height and width proximate the outlet, where the fourth height and width are substantially the same as the first height and width.

  4. Regional fluid migration in the Illinois basin: evidence from in situ oxygen isotope analysis of authigenic K-feldspar and quartz from the Mount Simon Sandstone

    USGS Publications Warehouse

    Chen, Zhensheng; Riciputi, Lee R.; Mora, Claudia I.; Fishman, Neil S.

    2001-01-01

    Oxygen isotope compositions of widespread, authigenic K-feldspar and quartz overgrowths and cements in the Upper Cambrian Mount Simon Sandstone were measured by ion microprobe in 11 samples distributed across the Illinois basin and its periphery. Average K-feldspar δ18O values increase systematically from +14‰ ± 1‰ in the southernmost and deepest samples in Illinois to +24‰ ± 2‰ in the northernmost outcrop sample in Wisconsin. A similar trend was observed for quartz overgrowths (22‰ ± 2‰ to 28‰ ± 2‰). Constant homogenization temperatures (100–130 °C) of fluid inclusions associated with quartz overgrowths throughout the basin suggest that the geographic trend in oxygen isotope compositions is a result of diagenetic modification of a south to north migrating basinal fluid.

  5. Tinea capitis in Botswana.

    PubMed

    Thakur, Rameshwari

    2013-01-01

    Tinea capitis (TC) is a common dermatophyte infection of the scalp that can also involve the eyebrows and eyelashes. This study aimed to find the causative fungus responsible for TC in Botswana and determine its association with the clinical types of TC. Samples for potassium hydroxide 10% mounts and fungal cultures were collected in a microbiology laboratory at the National Health Laboratory, Gaborone, Botswana. Dermasel agar and Sabouraud dextrose agar were inoculated with the samples. Lactophenol cotton blue mounts were prepared from the culture-positive samples to study the morphological characteristics. Trichophyton violaceum was found to be the predominant causative organism of TC. Trichophyton tonsurans was isolated from one patient. Both are anthropophilic species. TC was found to be most common in those aged 1-15 years (81%). Of 17 patients in this age group, 16 were younger than 10 years old and one was 14 years old. T. violaceum was the most common dermatophyte species isolated.

  6. Microfluidic-Based Platform for Universal Sample Preparation and Biological Assays Automation for Life-Sciences Research and Remote Medical Applications

    NASA Astrophysics Data System (ADS)

    Brassard, D.; Clime, L.; Daoud, J.; Geissler, M.; Malic, L.; Charlebois, D.; Buckley, N.; Veres, T.

    2018-02-01

    An innovative centrifugal microfluidic universal platform for remote bio-analytical assays automation required in life-sciences research and medical applications, including purification and analysis from body fluids of cellular and circulating markers.

  7. Application of the BioMek 2000 Laboratory Automation Workstation and the DNA IQ System to the extraction of forensic casework samples.

    PubMed

    Greenspoon, Susan A; Ban, Jeffrey D; Sykes, Karen; Ballard, Elizabeth J; Edler, Shelley S; Baisden, Melissa; Covington, Brian L

    2004-01-01

    Robotic systems are commonly utilized for the extraction of database samples. However, the application of robotic extraction to forensic casework samples is a more daunting task. Such a system must be versatile enough to accommodate a wide range of samples that may contain greatly varying amounts of DNA, but it must also pose no more risk of contamination than the manual DNA extraction methods. This study demonstrates that the BioMek 2000 Laboratory Automation Workstation, used in combination with the DNA IQ System, is versatile enough to accommodate the wide range of samples typically encountered by a crime laboratory. The use of a silica coated paramagnetic resin, as with the DNA IQ System, facilitates the adaptation of an open well, hands off, robotic system to the extraction of casework samples since no filtration or centrifugation steps are needed. Moreover, the DNA remains tightly coupled to the silica coated paramagnetic resin for the entire process until the elution step. A short pre-extraction incubation step is necessary prior to loading samples onto the robot and it is at this step that most modifications are made to accommodate the different sample types and substrates commonly encountered with forensic evidentiary samples. Sexual assault (mixed stain) samples, cigarette butts, blood stains, buccal swabs, and various tissue samples were successfully extracted with the BioMek 2000 Laboratory Automation Workstation and the DNA IQ System, with no evidence of contamination throughout the extensive validation studies reported here.

  8. Automated sample area definition for high-throughput microscopy.

    PubMed

    Zeder, M; Ellrott, A; Amann, R

    2011-04-01

    High-throughput screening platforms based on epifluorescence microscopy are powerful tools in a variety of scientific fields. Although some applications are based on imaging geometrically defined samples such as microtiter plates, multiwell slides, or spotted gene arrays, others need to cope with inhomogeneously located samples on glass slides. The analysis of microbial communities in aquatic systems by sample filtration on membrane filters followed by multiple fluorescent staining, or the investigation of tissue sections are examples. Therefore, we developed a strategy for flexible and fast definition of sample locations by the acquisition of whole slide overview images and automated sample recognition by image analysis. Our approach was tested on different microscopes and the computer programs are freely available (http://www.technobiology.ch). Copyright © 2011 International Society for Advancement of Cytometry.

  9. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of antimony by automated-hydride atomic absorption spectrophotometry

    USGS Publications Warehouse

    Brown, G.E.; McLain, B.J.

    1994-01-01

    The analysis of natural-water samples for antimony by automated-hydride atomic absorption spectrophotometry is described. Samples are prepared for analysis by addition of potassium and hydrochloric acid followed by an autoclave digestion. After the digestion, potassium iodide and sodium borohydride are added automatically. Antimony hydride (stibine) gas is generated, then swept into a heated quartz cell for determination of antimony by atomic absorption spectrophotometry. Precision and accuracy data are presented. Results obtained on standard reference water samples agree with means established by interlaboratory studies. Spike recoveries for actual samples range from 90 to 114 percent. Replicate analyses of water samples of varying matrices give relative standard deviations from 3 to 10 percent.

  10. Device and method for automated separation of a sample of whole blood into aliquots

    DOEpatents

    Burtis, Carl A.; Johnson, Wayne F.

    1989-01-01

    A device and a method for automated processing and separation of an unmeasured sample of whole blood into multiple aliquots of plasma. Capillaries are radially oriented on a rotor, with the rotor defining a sample chamber, transfer channels, overflow chamber, overflow channel, vent channel, cell chambers, and processing chambers. A sample of whole blood is placed in the sample chamber, and when the rotor is rotated, the blood moves outward through the transfer channels to the processing chambers where the blood is centrifugally separated into a solid cellular component and a liquid plasma component. When the rotor speed is decreased, the plasma component backfills the capillaries resulting in uniform aliquots of plasma which may be used for subsequent analytical procedures.

  11. The laboratory station for tyres grip testing on different surfaces

    NASA Astrophysics Data System (ADS)

    Kalinowski, K.; Grabowik, C.; Janik, W.; Ćwikła, G.; Skowera, M.

    2015-11-01

    The paper presents the conception of the device for tyre grip testing in the laboratory conditions. The main purpose is to provide a device working in confined spaces, which enables rapid changes of the tested samples of the road surfaces. Among the key assumptions the minimization of the device dimensions and the relative ease of transportation and mobility - the ability to quick assemble and disassemble were also assumed. The main components of the projected workstation includes: the replaceable platform for mounting samples of a road surface, the roller conveyor, the drive of the platform, the wheel mounting assembly and the axial force measuring system. At the design the station a morphological structure method has been used, particular elements have been optimized individually.

  12. The Degree and Nature to Which Public School Libraries Are Automated: A Survey of Public School Libraries in Ohio.

    ERIC Educational Resources Information Center

    Meckler, Elizabeth M.

    This paper examines the belief that no more than half of the public school libraries in the state of Ohio are automated to any degree. The purpose of the research was to determine the degree and nature of automation at the public school libraries in Ohio. A written survey was mailed to 350 libraries that represented a randomized sample of the…

  13. Determination of $sup 241$Am in soil using an automated nuclear radiation measurement laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engstrom, D.E.; White, M.G.; Dunaway, P.B.

    The recent completion of REECo's Automated Laboratory and associated software systems has provided a significant increase in capability while reducing manpower requirements. The system is designed to perform gamma spectrum analyses on the large numbers of samples required by the current Nevada Applied Ecology Group (NAEG) and Plutonium Distribution Inventory Program (PDIP) soil sampling programs while maintaining sufficient sensitivities as defined by earlier investigations of the same type. The hardware and systems are generally described in this paper, with emphasis being placed on spectrum reduction and the calibration procedures used for soil samples. (auth)

  14. Greek marbles: determination of provenance by isotopic analysis.

    PubMed

    Craig, H; Craig, V

    1972-04-28

    A study has been made of carbon-13 and oxygen-18 variations in Greek marbles from the ancient quarry localities of Naxos, Paros, Mount Hymettus, and Mount Pentelikon. Parian, Hymettian, and Pentelic marbles can be clearly distinguished by the isotopic relationships; Naxian marbles fall into two groups characterized by different oxygen-18/oxygen-16 ratios. Ten archeological samples were also analyzed; the isotopic data indicate that the "Theseion" is made of Pentelic marble and a block in the Treasury of Siphnos at Delphi is probably Parian marble.

  15. User's guide for a computer program to analyze the LRC 16 ft transonic dynamics tunnel cable mount system

    NASA Technical Reports Server (NTRS)

    Barbero, P.; Chin, J.

    1973-01-01

    The theoretical derivation of the set of equations is discussed which is applicable to modeling the dynamic characteristics of aeroelastically-scaled models flown on the two-cable mount system in a 16 ft transonic dynamics tunnel. The computer program provided for the analysis is also described. The program calculates model trim conditions as well as 3 DOF longitudinal and lateral/directional dynamic conditions for various flying cable and snubber cable configurations. Sample input and output are included.

  16. Investigation of discrete component chip mounting technology for hybrid microelectronic circuits

    NASA Technical Reports Server (NTRS)

    Caruso, S. V.; Honeycutt, J. O.

    1975-01-01

    The use of polymer adhesives for high reliability microcircuit applications is a radical deviation from past practices in electronic packaging. Bonding studies were performed using two gold-filled conductive adhesives, 10/90 tin/lead solder and Indalloy no. 7 solder. Various types of discrete components were mounted on ceramic substrates using both thick-film and thin-film metallization. Electrical and mechanical testing were performed on the samples before and after environmental exposure to MIL-STD-883 screening tests.

  17. Double window viewing chamber assembly

    NASA Technical Reports Server (NTRS)

    Keller, V. W. (Inventor); Owen, R. B. (Inventor); Elkins, B. R. (Inventor); White, W. T. (Inventor)

    1986-01-01

    A viewing chamber which permits observation of a sample retained therein includes a pair of double window assemblies mounted in opposed openings in the walls thereof so that a light beam can directly enter and exit from the chamber. A flexible mounting arrangement for the outer windows of the window assemblies enables the windows to be brought into proper alignment. An electrical heating arrangement prevents fogging of the outer windows whereas desiccated air in the volume between the outer and inner windows prevents fogging of the latter.

  18. Fully automated, internally controlled quantification of hepatitis B Virus DNA by real-time PCR by use of the MagNA Pure LC and LightCycler instruments.

    PubMed

    Leb, Victoria; Stöcher, Markus; Valentine-Thon, Elizabeth; Hölzl, Gabriele; Kessler, Harald; Stekel, Herbert; Berg, Jörg

    2004-02-01

    We report on the development of a fully automated real-time PCR assay for the quantitative detection of hepatitis B virus (HBV) DNA in plasma with EDTA (EDTA plasma). The MagNA Pure LC instrument was used for automated DNA purification and automated preparation of PCR mixtures. Real-time PCR was performed on the LightCycler instrument. An internal amplification control was devised as a PCR competitor and was introduced into the assay at the stage of DNA purification to permit monitoring for sample adequacy. The detection limit of the assay was found to be 200 HBV DNA copies/ml, with a linear dynamic range of 8 orders of magnitude. When samples from the European Union Quality Control Concerted Action HBV Proficiency Panel 1999 were examined, the results were found to be in acceptable agreement with the HBV DNA concentrations of the panel members. In a clinical laboratory evaluation of 123 EDTA plasma samples, a significant correlation was found with the results obtained by the Roche HBV Monitor test on the Cobas Amplicor analyzer within the dynamic range of that system. In conclusion, the newly developed assay has a markedly reduced hands-on time, permits monitoring for sample adequacy, and is suitable for the quantitative detection of HBV DNA in plasma in a routine clinical laboratory.

  19. Carotid Catheterization and Automated Blood Sampling Induce Systemic IL-6 Secretion and Local Tissue Damage and Inflammation in the Heart, Kidneys, Liver and Salivary Glands in NMRI Mice.

    PubMed

    Teilmann, Anne Charlotte; Rozell, Björn; Kalliokoski, Otto; Hau, Jann; Abelson, Klas S P

    2016-01-01

    Automated blood sampling through a vascular catheter is a frequently utilized technique in laboratory mice. The potential immunological and physiological implications associated with this technique have, however, not been investigated in detail. The present study compared plasma levels of the cytokines IL-1β, IL-2, IL-6, IL-10, IL-17A, GM-CSF, IFN-γ and TNF-α in male NMRI mice that had been subjected to carotid artery catheterization and subsequent automated blood sampling with age-matched control mice. Body weight and histopathological changes in the surgical area, including the salivary glands, the heart, brain, spleen, liver, kidneys and lungs were compared. Catheterized mice had higher levels of IL-6 than did control mice, but other cytokine levels did not differ between the groups. No significant difference in body weight was found. The histology revealed inflammatory and regenerative (healing) changes at surgical sites of all catheterized mice, with mild inflammatory changes extending into the salivary glands. Several catheterized mice had multifocal degenerative to necrotic changes with inflammation in the heart, kidneys and livers, suggesting that thrombi had detached from the catheter tip and embolized to distant sites. Thus, catheterization and subsequent automated blood sampling may have physiological impact. Possible confounding effects of visceral damage should be assessed and considered, when using catheterized mouse models.

  20. Analysis of nitrosamines in water by automated SPE and isotope dilution GC/HRMS Occurrence in the different steps of a drinking water treatment plant, and in chlorinated samples from a reservoir and a sewage treatment plant effluent.

    PubMed

    Planas, Carles; Palacios, Oscar; Ventura, Francesc; Rivera, Josep; Caixach, Josep

    2008-08-15

    A method based on automated solid-phase extraction (SPE) and isotope dilution gas chromatography/high resolution mass spectrometry (GC/HRMS) has been developed for the analysis of nine nitrosamines in water samples. The combination of automated SPE and GC/HRMS for the analysis of nitrosamines has not been reported previously. The method shows as advantages the selectivity and sensitivity of GC/HRMS analysis and the high efficiency of automated SPE with coconut charcoal EPA 521 cartridges. Low method detection limits (MDLs) were achieved, along with a greater facility of the procedure and less dependence on the operator with regard to the methods based on manual SPE. Quality requirements for isotope dilution-based methods were accomplished for most analysed nitrosamines, regarding to trueness (80-120%), method precision (<15%) and MDLs (0.08-1.7 ng/L). Nineteen water samples (16 samples from a drinking water treatment plant {DWTP}, 2 chlorinated samples from a sewage treatment plant {STP} effluent, and 1 chlorinated sample from a reservoir) were analysed. Concentrations of nitrosamines in the STP effluent were 309.4 and 730.2 ng/L, being higher when higher doses of chlorine were applied. N-Nitrosodimethylamine (NDMA) and N-nitrosodiethylamine (NDEA) were the main compounds identified in the STP effluent, and NDEA was detected above 200 ng/L, regulatory level for NDMA in effluents stated in Ontario (Canada). Lower concentrations of nitrosamines were found in the reservoir (20.3 ng/L) and in the DWTP samples (n.d. -28.6 ng/L). NDMA and NDEA were respectively found in the reservoir and in treated and highly chlorinated DWTP samples at concentrations above 10 ng/L (guide value established in different countries). The highest concentrations of nitrosamines were found after chlorination and ozonation processes (ozonated, treated and highly chlorinated water) in DWTP samples.