Sample records for automated sample transfer

  1. Automated PCR setup for forensic casework samples using the Normalization Wizard and PCR Setup robotic methods.

    PubMed

    Greenspoon, S A; Sykes, K L V; Ban, J D; Pollard, A; Baisden, M; Farr, M; Graham, N; Collins, B L; Green, M M; Christenson, C C

    2006-12-20

    Human genome, pharmaceutical and research laboratories have long enjoyed the application of robotics to performing repetitive laboratory tasks. However, the utilization of robotics in forensic laboratories for processing casework samples is relatively new and poses particular challenges. Since the quantity and quality (a mixture versus a single source sample, the level of degradation, the presence of PCR inhibitors) of the DNA contained within a casework sample is unknown, particular attention must be paid to procedural susceptibility to contamination, as well as DNA yield, especially as it pertains to samples with little biological material. The Virginia Department of Forensic Science (VDFS) has successfully automated forensic casework DNA extraction utilizing the DNA IQ(trade mark) System in conjunction with the Biomek 2000 Automation Workstation. Human DNA quantitation is also performed in a near complete automated fashion utilizing the AluQuant Human DNA Quantitation System and the Biomek 2000 Automation Workstation. Recently, the PCR setup for casework samples has been automated, employing the Biomek 2000 Automation Workstation and Normalization Wizard, Genetic Identity version, which utilizes the quantitation data, imported into the software, to create a customized automated method for DNA dilution, unique to that plate of DNA samples. The PCR Setup software method, used in conjunction with the Normalization Wizard method and written for the Biomek 2000, functions to mix the diluted DNA samples, transfer the PCR master mix, and transfer the diluted DNA samples to PCR amplification tubes. Once the process is complete, the DNA extracts, still on the deck of the robot in PCR amplification strip tubes, are transferred to pre-labeled 1.5 mL tubes for long-term storage using an automated method. The automation of these steps in the process of forensic DNA casework analysis has been accomplished by performing extensive optimization, validation and testing of the software methods.

  2. Automated Dissolution for Enteric-Coated Aspirin Tablets: A Case Study for Method Transfer to a RoboDis II.

    PubMed

    Ibrahim, Sarah A; Martini, Luigi

    2014-08-01

    Dissolution method transfer is a complicated yet common process in the pharmaceutical industry. With increased pharmaceutical product manufacturing and dissolution acceptance requirements, dissolution testing has become one of the most labor-intensive quality control testing methods. There is an increased trend for automation in dissolution testing, particularly for large pharmaceutical companies to reduce variability and increase personnel efficiency. There is no official guideline for dissolution testing method transfer from a manual, semi-automated, to automated dissolution tester. In this study, a manual multipoint dissolution testing procedure for an enteric-coated aspirin tablet was transferred effectively and reproducibly to a fully automated dissolution testing device, RoboDis II. Enteric-coated aspirin samples were used as a model formulation to assess the feasibility and accuracy of media pH change during continuous automated dissolution testing. Several RoboDis II parameters were evaluated to ensure the integrity and equivalency of dissolution method transfer from a manual dissolution tester. This current study provides a systematic outline for the transfer of the manual dissolution testing protocol to an automated dissolution tester. This study further supports that automated dissolution testers compliant with regulatory requirements and similar to manual dissolution testers facilitate method transfer. © 2014 Society for Laboratory Automation and Screening.

  3. Device and method for automated separation of a sample of whole blood into aliquots

    DOEpatents

    Burtis, Carl A.; Johnson, Wayne F.

    1989-01-01

    A device and a method for automated processing and separation of an unmeasured sample of whole blood into multiple aliquots of plasma. Capillaries are radially oriented on a rotor, with the rotor defining a sample chamber, transfer channels, overflow chamber, overflow channel, vent channel, cell chambers, and processing chambers. A sample of whole blood is placed in the sample chamber, and when the rotor is rotated, the blood moves outward through the transfer channels to the processing chambers where the blood is centrifugally separated into a solid cellular component and a liquid plasma component. When the rotor speed is decreased, the plasma component backfills the capillaries resulting in uniform aliquots of plasma which may be used for subsequent analytical procedures.

  4. Automated saliva processing for LC-MS/MS: Improving laboratory efficiency in cortisol and cortisone testing.

    PubMed

    Antonelli, Giorgia; Padoan, Andrea; Artusi, Carlo; Marinova, Mariela; Zaninotto, Martina; Plebani, Mario

    2016-04-01

    The aim of this study was to implement in our routine practice an automated saliva preparation protocol for quantification of cortisol (F) and cortisone (E) by LC-MS/MS using a liquid handling platform, maintaining the previously defined reference intervals with the manual preparation. Addition of internal standard solution to saliva samples and calibrators and SPE on μ-elution 96-well plate were performed by liquid handling platform. After extraction, the eluates were submitted to LC-MS/MS analysis. The manual steps within the entire process were to transfer saliva samples in suitable tubes, to put the cap mat and transfer of the collection plate to the LC auto sampler. Transference of the reference intervals from the manual to the automated procedure was established by Passing Bablok regression on 120 saliva samples analyzed simultaneously with the two procedures. Calibration curves were linear throughout the selected ranges. The imprecision ranged from 2 to 10%, with recoveries from 95 to 116%. Passing Bablok regression demonstrated no significant bias. The liquid handling platform translates the manual steps into automated operations allowing for saving hands-on time, while maintaining assay reproducibility and ensuring reliability of results, making it implementable in our routine with the previous established reference intervals. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  5. A 96-well screen filter plate for high-throughput biological sample preparation and LC-MS/MS analysis.

    PubMed

    Peng, Sean X; Cousineau, Martin; Juzwin, Stephen J; Ritchie, David M

    2006-01-01

    A novel 96-well screen filter plate (patent pending) has been invented to eliminate a time-consuming and labor-intensive step in preparation of in vivo study samples--to remove blood or plasma clots. These clots plug the pipet tips during a manual or automated sample-transfer step causing inaccurate pipetting or total pipetting failure. Traditionally, these blood and plasma clots are removed by picking them out manually one by one from each sample tube before any sample transfer can be made. This has significantly slowed the sample preparation process and has become a bottleneck for automated high-throughput sample preparation using robotic liquid handlers. Our novel screen filter plate was developed to solve this problem. The 96-well screen filter plate consists of 96 stainless steel wire-mesh screen tubes connected to the 96 openings of a top plate so that the screen filter plate can be readily inserted into a 96-well sample storage plate. Upon insertion, the blood and plasma clots are excluded from entering the screen tube while clear sample solutions flow freely into it. In this way, sample transfer can be easily completed by either manual or automated pipetting methods. In this report, three structurally diverse compounds were selected to evaluate and validate the use of the screen filter plate. The plasma samples of these compounds were transferred and processed in the presence and absence of the screen filter plate and then analyzed by LC-MS/MS methods. Our results showed a good agreement between the samples prepared with and without the screen filter plate, demonstrating the utility and efficiency of this novel device for preparation of blood and plasma samples. The device is simple, easy to use, and reusable. It can be employed for sample preparation of other biological fluids that contain floating particulates or aggregates.

  6. Universal microfluidic automaton for autonomous sample processing: application to the Mars Organic Analyzer.

    PubMed

    Kim, Jungkyu; Jensen, Erik C; Stockton, Amanda M; Mathies, Richard A

    2013-08-20

    A fully integrated multilayer microfluidic chemical analyzer for automated sample processing and labeling, as well as analysis using capillary zone electrophoresis is developed and characterized. Using lifting gate microfluidic control valve technology, a microfluidic automaton consisting of a two-dimensional microvalve cellular array is fabricated with soft lithography in a format that enables facile integration with a microfluidic capillary electrophoresis device. The programmable sample processor performs precise mixing, metering, and routing operations that can be combined to achieve automation of complex and diverse assay protocols. Sample labeling protocols for amino acid, aldehyde/ketone and carboxylic acid analysis are performed automatically followed by automated transfer and analysis by the integrated microfluidic capillary electrophoresis chip. Equivalent performance to off-chip sample processing is demonstrated for each compound class; the automated analysis resulted in a limit of detection of ~16 nM for amino acids. Our microfluidic automaton provides a fully automated, portable microfluidic analysis system capable of autonomous analysis of diverse compound classes in challenging environments.

  7. Semi-automated 96-well liquid-liquid extraction for quantitation of drugs in biological fluids.

    PubMed

    Zhang, N; Hoffman, K L; Li, W; Rossi, D T

    2000-02-01

    A semi-automated liquid-liquid extraction (LLE) technique for biological fluid sample preparation was introduced for the quantitation of four drugs in rat plasma. All liquid transferring during the sample preparation was automated using a Tomtec Quadra 96 Model 320 liquid handling robot, which processed up to 96 samples in parallel. The samples were either in 96-deep-well plate or tube-rack format. One plate of samples can be prepared in approximately 1.5 h, and the 96-well plate is directly compatible with the autosampler of an LC/MS system. Selection of organic solvents and recoveries are discussed. Also, precision, relative error, linearity and quantitation of the semi automated LLE method are estimated for four example drugs using LC/MS/MS with a multiple reaction monitoring (MRM) approach. The applicability of this method and future directions are evaluated.

  8. Automated processing of whole blood samples for the determination of immunosuppressants by liquid chromatography tandem-mass spectrometry.

    PubMed

    Vogeser, Michael; Spöhrer, Ute

    2006-01-01

    Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is an efficient technology for routine determination of immunosuppressants in whole blood; however, time-consuming manual sample preparation remains a significant limitation of this technique. Using a commercially available robotic pipetting system (Tecan Freedom EVO), we developed an automated sample-preparation protocol for quantification of tacrolimus in whole blood by LC-MS/MS. Barcode reading, sample resuspension, transfer of whole blood aliquots into a deep-well plate, addition of internal standard solution, mixing, and protein precipitation by addition of an organic solvent is performed by the robotic system. After centrifugation of the plate, the deproteinized supernatants are submitted to on-line solid phase extraction, using column switching prior to LC-MS/MS analysis. The only manual actions within the entire process are decapping of the tubes, and transfer of the deep-well plate from the robotic system to a centrifuge and finally to the HPLC autosampler. Whole blood pools were used to assess the reproducibility of the entire analytical system for measuring tacrolimus concentrations. A total coefficient of variation of 1.7% was found for the entire automated analytical process (n=40; mean tacrolimus concentration, 5.3 microg/L). Close agreement between tacrolimus results obtained after manual and automated sample preparation was observed. The analytical system described here, comprising automated protein precipitation, on-line solid phase extraction and LC-MS/MS analysis, is convenient and precise, and minimizes hands-on time and the risk of mistakes in the quantification of whole blood immunosuppressant concentrations compared to conventional methods.

  9. High-throughput and automated SAXS/USAXS experiment for industrial use at BL19B2 in SPring-8

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Osaka, Keiichi, E-mail: k-osaka@spring8.or.jp; Inoue, Daisuke; Sato, Masugu

    A highly automated system combining a sample transfer robot with focused SR beam has been established for small-angle and ultra small-angle X-ray scattering (SAXS/USAXS) measurement at BL19B2 for industrial use of SPring-8. High-throughput data collection system can be realized by means of X-ray beam of high photon flux density concentrated by a cylindrical mirror, and a two-dimensional pixel detector PILATUS-2M. For SAXS measurement, we can obtain high-quality data within 1 minute for one exposure using this system. The sample transfer robot has a capacity of 90 samples with a large variety of shapes. The fusion of high-throughput and robotic systemmore » has enhanced the usability of SAXS/USAXS capability for industrial application.« less

  10. High-throughput microcoil NMR of compound libraries using zero-dispersion segmented flow analysis.

    PubMed

    Kautz, Roger A; Goetzinger, Wolfgang K; Karger, Barry L

    2005-01-01

    An automated system for loading samples into a microcoil NMR probe has been developed using segmented flow analysis. This approach enhanced 2-fold the throughput of the published direct injection and flow injection methods, improved sample utilization 3-fold, and was applicable to high-field NMR facilities with long transfer lines between the sample handler and NMR magnet. Sample volumes of 2 microL (10-30 mM, approximately 10 microg) were drawn from a 96-well microtiter plate by a sample handler, then pumped to a 0.5-microL microcoil NMR probe as a queue of closely spaced "plugs" separated by an immiscible fluorocarbon fluid. Individual sample plugs were detected by their NMR signal and automatically positioned for stopped-flow data acquisition. The sample in the NMR coil could be changed within 35 s by advancing the queue. The fluorocarbon liquid wetted the wall of the Teflon transfer line, preventing the DMSO samples from contacting the capillary wall and thus reducing sample losses to below 5% after passage through the 3-m transfer line. With a wash plug of solvent between samples, sample-to-sample carryover was <1%. Significantly, the samples did not disperse into the carrier liquid during loading or during acquisitions of several days for trace analysis. For automated high-throughput analysis using a 16-second acquisition time, spectra were recorded at a rate of 1.5 min/sample and total deuterated solvent consumption was <0.5 mL (1 US dollar) per 96-well plate.

  11. Development of automated high throughput single molecular microfluidic detection platform for signal transduction analysis

    NASA Astrophysics Data System (ADS)

    Huang, Po-Jung; Baghbani Kordmahale, Sina; Chou, Chao-Kai; Yamaguchi, Hirohito; Hung, Mien-Chie; Kameoka, Jun

    2016-03-01

    Signal transductions including multiple protein post-translational modifications (PTM), protein-protein interactions (PPI), and protein-nucleic acid interaction (PNI) play critical roles for cell proliferation and differentiation that are directly related to the cancer biology. Traditional methods, like mass spectrometry, immunoprecipitation, fluorescence resonance energy transfer, and fluorescence correlation spectroscopy require a large amount of sample and long processing time. "microchannel for multiple-parameter analysis of proteins in single-complex (mMAPS)"we proposed can reduce the process time and sample volume because this system is composed by microfluidic channels, fluorescence microscopy, and computerized data analysis. In this paper, we will present an automated mMAPS including integrated microfluidic device, automated stage and electrical relay for high-throughput clinical screening. Based on this result, we estimated that this automated detection system will be able to screen approximately 150 patient samples in a 24-hour period, providing a practical application to analyze tissue samples in a clinical setting.

  12. An Automated, High-Throughput System for GISAXS and GIWAXS Measurements of Thin Films

    NASA Astrophysics Data System (ADS)

    Schaible, Eric; Jimenez, Jessica; Church, Matthew; Lim, Eunhee; Stewart, Polite; Hexemer, Alexander

    Grazing incidence small-angle X-ray scattering (GISAXS) and grazing incidence wide-angle X-ray scattering (GIWAXS) are important techniques for characterizing thin films. In order to meet rapidly increasing demand, the SAXSWAXS beamline at the Advanced Light Source (beamline 7.3.3) has implemented a fully automated, high-throughput system to conduct SAXS, GISAXS and GIWAXS measurements. An automated robot arm transfers samples from a holding tray to a measurement stage. Intelligent software aligns each sample in turn, and measures each according to user-defined specifications. Users mail in trays of samples on individually barcoded pucks, and can download and view their data remotely. Data will be pipelined to the NERSC supercomputing facility, and will be available to users via a web portal that facilitates highly parallelized analysis.

  13. Flexible Automation System for Determination of Elemental Composition of Incrustations in Clogged Biliary Endoprostheses Using ICP-MS.

    PubMed

    Fleischer, Heidi; Ramani, Kinjal; Blitti, Koffi; Roddelkopf, Thomas; Warkentin, Mareike; Behrend, Detlef; Thurow, Kerstin

    2018-02-01

    Automation systems are well established in industries and life science laboratories, especially in bioscreening and high-throughput applications. An increasing demand of automation solutions can be seen in the field of analytical measurement in chemical synthesis, quality control, and medical and pharmaceutical fields, as well as research and development. In this study, an automation solution was developed and optimized for the investigation of new biliary endoprostheses (stents), which should reduce clogging after implantation in the human body. The material inside the stents (incrustations) has to be controlled regularly and under identical conditions. The elemental composition is one criterion to be monitored in stent development. The manual procedure was transferred to an automated process including sample preparation, elemental analysis using inductively coupled plasma mass spectrometry (ICP-MS), and data evaluation. Due to safety issues, microwave-assisted acid digestion was executed outside of the automation system. The performance of the automated process was determined and validated. The measurement results and the processing times were compared for both the manual and the automated procedure. Finally, real samples of stent incrustations and pig bile were analyzed using the automation system.

  14. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--NHEXAS FILTER HANDLING, WEIGHING AND ARCHIVING PROCEDURES FOR AEROSOL SAMPLES (RTI/ACS-AP-209-011)

    EPA Science Inventory

    This protocol describes the procedures for weighing, handling, and archiving aerosol filters and for managing the associated analytical and quality assurance data. Filter samples were weighed for aerosol mass at RTI laboratory, with only the automated field sampling data transfer...

  15. Immunosuppressant therapeutic drug monitoring by LC-MS/MS: workflow optimization through automated processing of whole blood samples.

    PubMed

    Marinova, Mariela; Artusi, Carlo; Brugnolo, Laura; Antonelli, Giorgia; Zaninotto, Martina; Plebani, Mario

    2013-11-01

    Although, due to its high specificity and sensitivity, LC-MS/MS is an efficient technique for the routine determination of immunosuppressants in whole blood, it involves time-consuming manual sample preparation. The aim of the present study was therefore to develop an automated sample-preparation protocol for the quantification of sirolimus, everolimus and tacrolimus by LC-MS/MS using a liquid handling platform. Six-level commercially available blood calibrators were used for assay development, while four quality control materials and three blood samples from patients under immunosuppressant treatment were employed for the evaluation of imprecision. Barcode reading, sample re-suspension, transfer of whole blood samples into 96-well plates, addition of internal standard solution, mixing, and protein precipitation were performed with a liquid handling platform. After plate filtration, the deproteinised supernatants were submitted for SPE on-line. The only manual steps in the entire process were de-capping of the tubes, and transfer of the well plates to the HPLC autosampler. Calibration curves were linear throughout the selected ranges. The imprecision and accuracy data for all analytes were highly satisfactory. The agreement between the results obtained with manual and those obtained with automated sample preparation was optimal (n=390, r=0.96). In daily routine (100 patient samples) the typical overall total turnaround time was less than 6h. Our findings indicate that the proposed analytical system is suitable for routine analysis, since it is straightforward and precise. Furthermore, it incurs less manual workload and less risk of error in the quantification of whole blood immunosuppressant concentrations than conventional methods. © 2013.

  16. Through oven transfer adsorption-desorption interface for the analysis of methyl jasmonate in aromatic samples by on-line RPLC-GC.

    PubMed

    Flores, Gema; Blanch, Gracia Patricia; Ruiz del Castillo, Maria Luisa

    2008-04-01

    A fully automated method for the determination of medium volatility compounds in aromatic samples was developed. Specifically, the determination of methyl jasmonate in jasmine fragrances was performed by using the through oven transfer adsorption-desorption (TOTAD) interface for the on-line coupling between RPLC-GC. A study of the most relevant variables involved in the performance of the TOTAD interface for medium volatility compounds was carried out by testing different values of helium flow (100, 300, 400, and 500 mL/min), transfer speed (0.1, 0.3, 0.5, and 2.0 mL/min), and methanol/water percentages (86:14, 85:15, 83:17, 80:20, and 70:30). The method developed provided satisfactory repeatability (RSD for retention times of 0.15% and for peak areas of 9.4%) and recovery (71%) as well as excellent LOD (0.01 mg/L) for methyl jasmonate in commercial jasmine essence under the experimental conditions selected as optimum. Additional advantages of the automated RPLC-TOTAD-GC method proposed in the present work are its rapidness, reliability, and the possibility of directly introducing the sample with no further pretreatment.

  17. New hardware and workflows for semi-automated correlative cryo-fluorescence and cryo-electron microscopy/tomography.

    PubMed

    Schorb, Martin; Gaechter, Leander; Avinoam, Ori; Sieckmann, Frank; Clarke, Mairi; Bebeacua, Cecilia; Bykov, Yury S; Sonnen, Andreas F-P; Lihl, Reinhard; Briggs, John A G

    2017-02-01

    Correlative light and electron microscopy allows features of interest defined by fluorescence signals to be located in an electron micrograph of the same sample. Rare dynamic events or specific objects can be identified, targeted and imaged by electron microscopy or tomography. To combine it with structural studies using cryo-electron microscopy or tomography, fluorescence microscopy must be performed while maintaining the specimen vitrified at liquid-nitrogen temperatures and in a dry environment during imaging and transfer. Here we present instrumentation, software and an experimental workflow that improves the ease of use, throughput and performance of correlated cryo-fluorescence and cryo-electron microscopy. The new cryo-stage incorporates a specially modified high-numerical aperture objective lens and provides a stable and clean imaging environment. It is combined with a transfer shuttle for contamination-free loading of the specimen. Optimized microscope control software allows automated acquisition of the entire specimen area by cryo-fluorescence microscopy. The software also facilitates direct transfer of the fluorescence image and associated coordinates to the cryo-electron microscope for subsequent fluorescence-guided automated imaging. Here we describe these technological developments and present a detailed workflow, which we applied for automated cryo-electron microscopy and tomography of various specimens. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  18. 75 FR 51866 - Self-Regulatory Organizations; The Depository Trust Company; Order Approving Proposed Rule Change...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-23

    ... Regarding Securities Delivered to or From Participant Accounts Through the Automated Customer Account... Corporation (``NSCC'') concerning Automated Customer Account Transfer Service (``ACATS'') transfers processed... (July 2, 2010). NSCC's ACATS system enables members to effect automated transfers of customer accounts...

  19. Technology Transfer Opportunities: Automated Ground-Water Monitoring, A Proven Technology

    USGS Publications Warehouse

    Smith, Kirk P.; Granato, Gregory E.

    1998-01-01

    Introduction The U.S. Geological Survey (USGS) has developed and tested an automated ground-water monitoring system that measures and records values of selected water-quality properties and constituents using protocols approved for manual sampling. Prototypes using the automated process have demonstrated the ability to increase the quantity and quality of data collected and have shown the potential for reducing labor and material costs for ground-water quality data collection. Automated ground-water monitoring systems can be used to monitor known or potential contaminant sites, such as near landfills, underground storage tanks, or other facilities where potential contaminants are stored, to serve as early warning systems monitoring ground-water quality near public water-supply wells, and for ground-water quality research.

  20. 75 FR 51867 - Self-Regulatory Organizations; National Securities Clearing Corporation; Order Approving Proposed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-23

    ... Enhance the Process for Transfers Through the Automated Customer Account Transfer Service August 16, 2010... Transfer Service (``ACATS'') system enables Members to effect automated transfers of customer accounts... transfer services and to effect customer account transfers within specified time frames. \\4\\ CNS is an...

  1. 31 CFR 205.17 - Are funds transfers delayed by automated payment systems restrictions based on the size and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... automated payment systems restrictions based on the size and timing of the drawdown request subject to this... EFFICIENT FEDERAL-STATE FUNDS TRANSFERS Rules Applicable to Federal Assistance Programs Included in a Treasury-State Agreement § 205.17 Are funds transfers delayed by automated payment systems restrictions...

  2. 75 FR 38579 - Self-Regulatory Organizations; National Securities Clearing Corporation; Notice of Filing of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-02

    ... To Enhance the Process for Transfers Through the Automated Customer Account Transfer Service June 25... NSCC's process for transfers through the Automated Customer Account Transfer Service (``ACATS''). II... services and to effect customer account transfers within specified time frames. \\4\\ CNS is an ongoing...

  3. Icebreaker-3 Drill Integration and Testing at Two Mars-Analog Sites

    NASA Technical Reports Server (NTRS)

    Glass, B.; Bergman, D.; Yaggi, B.; Dave, A.; Zacny, K.

    2016-01-01

    A decade of evolutionary development of integrated automated drilling and sample handling at analog sites and in test chambers has made it possible to go 1 meter through hard rocks and ice layers on Mars. The latest Icebreaker-3 drill has been field tested in 2014 at the Haughton Crater Marsanalog site in the Arctic and in 2015 with a Mars lander mockup in Rio Tinto, Spain, (with sample transfer arm and with a prototype life-detection instrument). Tests in Rio Tinto in 2015 successfully demonstrated that the drill sample (cuttings) was handed-off from the drill to the sample transfer arm and thence to the on-deck instrument inlet where it was taken in and analyzed ("dirt-to-data").

  4. Digitally programmable microfluidic automaton for multiscale combinatorial mixing and sample processing†

    PubMed Central

    Jensen, Erik C.; Stockton, Amanda M.; Chiesl, Thomas N.; Kim, Jungkyu; Bera, Abhisek; Mathies, Richard A.

    2013-01-01

    A digitally programmable microfluidic Automaton consisting of a 2-dimensional array of pneumatically actuated microvalves is programmed to perform new multiscale mixing and sample processing operations. Large (µL-scale) volume processing operations are enabled by precise metering of multiple reagents within individual nL-scale valves followed by serial repetitive transfer to programmed locations in the array. A novel process exploiting new combining valve concepts is developed for continuous rapid and complete mixing of reagents in less than 800 ms. Mixing, transfer, storage, and rinsing operations are implemented combinatorially to achieve complex assay automation protocols. The practical utility of this technology is demonstrated by performing automated serial dilution for quantitative analysis as well as the first demonstration of on-chip fluorescent derivatization of biomarker targets (carboxylic acids) for microchip capillary electrophoresis on the Mars Organic Analyzer. A language is developed to describe how unit operations are combined to form a microfluidic program. Finally, this technology is used to develop a novel microfluidic 6-sample processor for combinatorial mixing of large sets (>26 unique combinations) of reagents. The digitally programmable microfluidic Automaton is a versatile programmable sample processor for a wide range of process volumes, for multiple samples, and for different types of analyses. PMID:23172232

  5. Technology Transfer Opportunities: Automated Ground-Water Monitoring

    USGS Publications Warehouse

    Smith, Kirk P.; Granato, Gregory E.

    1997-01-01

    Introduction A new automated ground-water monitoring system developed by the U.S. Geological Survey (USGS) measures and records values of selected water-quality properties and constituents using protocols approved for manual sampling. Prototypes using the automated process have demonstrated the ability to increase the quantity and quality of data collected and have shown the potential for reducing labor and material costs for ground-water quality data collection. Automation of water-quality monitoring systems in the field, in laboratories, and in industry have increased data density and utility while reducing operating costs. Uses for an automated ground-water monitoring system include, (but are not limited to) monitoring ground-water quality for research, monitoring known or potential contaminant sites, such as near landfills, underground storage tanks, or other facilities where potential contaminants are stored, and as an early warning system monitoring groundwater quality near public water-supply wells.

  6. Autonomous Data Transfer Operations for Missions

    NASA Technical Reports Server (NTRS)

    Repaci, Max; Baker, Paul; Brosi, Fred

    2000-01-01

    Automating the data transfer operation can significantly reduce the cost of moving data from a spacecraft to a location on Earth. Automated data transfer methods have been developed for the terrestrial Internet. However, they often do not apply to the space environment, since in general they are based on assumptions about connectivity that are true on the Internet but not on space links. Automated file transfer protocols have been developed for use over space links that transfer data via store-and-forward of files or segments of files. This paper investigates some of the operational concepts made possible by these protocols.

  7. A Chip-Capillary Hybrid Device for Automated Transfer of Sample Pre-Separated by Capillary Isoelectric Focusing to Parallel Capillary Gel Electrophoresis for Two-Dimensional Protein Separation

    PubMed Central

    Lu, Joann J.; Wang, Shili; Li, Guanbin; Wang, Wei; Pu, Qiaosheng; Liu, Shaorong

    2012-01-01

    In this report, we introduce a chip-capillary hybrid device to integrate capillary isoelectric focusing (CIEF) with parallel capillary sodium dodecyl sulfate – polyacrylamide gel electrophoresis (SDS-PAGE) or capillary gel electrophoresis (CGE) toward automating two-dimensional (2D) protein separations. The hybrid device consists of three chips that are butted together. The middle chip can be moved between two positions to re-route the fluidic paths, which enables the performance of CIEF and injection of proteins partially resolved by CIEF to CGE capillaries for parallel CGE separations in a continuous and automated fashion. Capillaries are attached to the other two chips to facilitate CIEF and CGE separations and to extend the effective lengths of CGE columns. Specifically, we illustrate the working principle of the hybrid device, develop protocols for producing and preparing the hybrid device, and demonstrate the feasibility of using this hybrid device for automated injection of CIEF-separated sample to parallel CGE for 2D protein separations. Potentials and problems associated with the hybrid device are also discussed. PMID:22830584

  8. Automated Mars surface sample return mission concepts for achievement of essential scientific objectives

    NASA Technical Reports Server (NTRS)

    Weaver, W. L.; Norton, H. N.; Darnell, W. L.

    1975-01-01

    Mission concepts were investigated for automated return to Earth of a Mars surface sample adequate for detailed analyses in scientific laboratories. The minimum sample mass sufficient to meet scientific requirements was determined. Types of materials and supporting measurements for essential analyses are reported. A baseline trajectory profile was selected for its low energy requirements and relatively simple implementation, and trajectory profile design data were developed for 1979 and 1981 launch opportunities. Efficient spacecraft systems were conceived by utilizing existing technology where possible. Systems concepts emphasized the 1979 launch opportunity, and the applicability of results to other opportunities was assessed. It was shown that the baseline missions (return through Mars parking orbit) and some comparison missions (return after sample transfer in Mars orbit) can be accomplished by using a single Titan III E/Centaur as the launch vehicle. All missions investigated can be accomplished by use of Space Shuttle/Centaur vehicles.

  9. An Automated Multi-Modal Serial Sectioning System for Characterization of Grain-Scale Microstructures in Engineering Materials (Preprint)

    DTIC Science & Technology

    2012-03-01

    the three main sub-systems. The Mitsubishi RV12SVL 6-axis robot arm has a 54’’ reach, which allows it to readily move a 2” diameter stainless ... steel sample holder, Figure 2A, between sample exchange points on the Robo-Met.3D, the Tescan SEM, and an additional sample transfer stand that enables...Rowenhorst DJ, et al. (2006) Crystallographic and morphological analysis of coarse martensite : Combining EBSD and serial sectioning. Scripta

  10. An automated online turboflow cleanup LC/MS/MS method for the determination of 11 plasticizers in beverages and milk.

    PubMed

    Ates, Ebru; Mittendorf, Klaus; Senyuva, Hamide

    2013-01-01

    An automated sample preparation technique involving cleanup and analytical separation in a single operation using an online coupled TurboFlow (RP-LC system) is reported. This method eliminates time-consuming sample preparation steps that can be potential sources for cross-contamination in the analysis of plasticizers. Using TurboFlow chromatography, liquid samples were injected directly into the automated system without previous extraction or cleanup. Special cleanup columns enabled specific binding of target compounds; higher MW compounds, i.e., fats and proteins, and other matrix interferences with different chemical properties were removed to waste, prior to LC/MS/MS. Systematic stepwise method development using this new technology in the food safety area is described. Selection of optimum columns and mobile phases for loading onto the cleanup column followed by transfer onto the analytical column and MS detection are critical method parameters. The method was optimized for the assay of 10 phthalates (dimethyl, diethyl, dipropyl, butyl benzyl, diisobutyl, dicyclohexyl, dihexyl, diethylhexyl, diisononyl, and diisododecyl) and one adipate (diethylhexyl) in beverages and milk.

  11. Assessing Information on the Internet: Toward Providing Library Services for Computer-Mediated Communication.

    ERIC Educational Resources Information Center

    Dillon, Martin; And Others

    1992-01-01

    Describes a project that examined textual information available on the Internet and potential means of providing access to this information. Highlights include an overview of Internet resources, a profile of a document sample, description of FTP (File Transfer Protocol) sites, and an automated method of categorizing files. (MES)

  12. Automation and heat transfer characterization of immersion mode spectroscopy for analysis of ice nucleating particles

    NASA Astrophysics Data System (ADS)

    Beall, Charlotte M.; Stokes, M. Dale; Hill, Thomas C.; DeMott, Paul J.; DeWald, Jesse T.; Prather, Kimberly A.

    2017-07-01

    Ice nucleating particles (INPs) influence cloud properties and can affect the overall precipitation efficiency. Developing a parameterization of INPs in global climate models has proven challenging. More INP measurements - including studies of their spatial distribution, sources and sinks, and fundamental freezing mechanisms - must be conducted in order to further improve INP parameterizations. In this paper, an immersion mode INP measurement technique is modified and automated using a software-controlled, real-time image stream designed to leverage optical changes of water droplets to detect freezing events. For the first time, heat transfer properties of the INP measurement technique are characterized using a finite-element-analysis-based heat transfer simulation to improve accuracy of INP freezing temperature measurement. The heat transfer simulation is proposed as a tool that could be used to explain the sources of bias in temperature measurements in INP measurement techniques and ultimately explain the observed discrepancies in measured INP freezing temperatures between different instruments. The simulation results show that a difference of +8.4 °C between the well base temperature and the headspace gas results in an up to 0.6 °C stratification of the aliquot, whereas a difference of +4.2 °C or less results in a thermally homogenous water volume within the error of the thermal probe, ±0.2 °C. The results also show that there is a strong temperature gradient in the immediate vicinity of the aliquot, such that without careful placement of temperature probes, or characterization of heat transfer properties of the water and cooling environment, INP measurements can be biased toward colder temperatures. Based on a modified immersion mode technique, the Automated Ice Spectrometer (AIS), measurements of the standard test dust illite NX are reported and compared against six other immersion mode droplet assay techniques featured in Hiranuma et al. (2015) that used wet suspensions. AIS measurements of illite NX INP freezing temperatures compare reasonably with others, falling within the 5 °C spread in reported spectra. The AIS as well as its characterization of heat transfer properties allows higher confidence in accuracy of freezing temperature measurement, allows higher throughput of sample analysis, and enables disentanglement of the effects of heat transfer rates on sample volumes from time dependence of ice nucleation.

  13. Robofurnace: A semi-automated laboratory chemical vapor deposition system for high-throughput nanomaterial synthesis and process discovery

    PubMed Central

    Oliver, C. Ryan; Westrick, William; Koehler, Jeremy; Brieland-Shoultz, Anna; Anagnostopoulos-Politis, Ilias; Cruz-Gonzalez, Tizoc; Hart, A. John

    2013-01-01

    Laboratory research and development on new materials, such as nanostructured thin films, often utilizes manual equipment such as tube furnaces due to its relatively low cost and ease of setup. However, these systems can be prone to inconsistent outcomes due to variations in standard operating procedures and limitations in performance such as heating and cooling rates restrict the parameter space that can be explored. Perhaps more importantly, maximization of research throughput and the successful and efficient translation of materials processing knowledge to production-scale systems, relies on the attainment of consistent outcomes. In response to this need, we present a semi-automated lab-scale chemical vapor deposition (CVD) furnace system, called “Robofurnace.” Robofurnace is an automated CVD system built around a standard tube furnace, which automates sample insertion and removal and uses motion of the furnace to achieve rapid heating and cooling. The system has a 10-sample magazine and motorized transfer arm, which isolates the samples from the lab atmosphere and enables highly repeatable placement of the sample within the tube. The system is designed to enable continuous operation of the CVD reactor, with asynchronous loading/unloading of samples. To demonstrate its performance, Robofurnace is used to develop a rapid CVD recipe for carbon nanotube (CNT) forest growth, achieving a 10-fold improvement in CNT forest mass density compared to a benchmark recipe using a manual tube furnace. In the long run, multiple systems like Robofurnace may be linked to share data among laboratories by methods such as Twitter. Our hope is Robofurnace and like automation will enable machine learning to optimize and discover relationships in complex material synthesis processes. PMID:24289435

  14. 76 FR 20425 - Self-Regulatory Organizations; National Securities Clearing Corporation; Order Approving Proposed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-12

    ... Relating to Establishing an Automated Service for the Processing of Transfers, Replacements, and Exchanges... (the ``Act'').\\1\\ The proposed rule change allows NSCC to add a new automated service to process... offer a new automated service for the transfer, replacement, or exchange (collectively referred to as a...

  15. A modular approach for automated sample preparation and chemical analysis

    NASA Technical Reports Server (NTRS)

    Clark, Michael L.; Turner, Terry D.; Klingler, Kerry M.; Pacetti, Randolph

    1994-01-01

    Changes in international relations, especially within the past several years, have dramatically affected the programmatic thrusts of the U.S. Department of Energy (DOE). The DOE now is addressing the environmental cleanup required as a result of 50 years of nuclear arms research and production. One major obstacle in the remediation of these areas is the chemical determination of potentially contaminated material using currently acceptable practices. Process bottlenecks and exposure to hazardous conditions pose problems for the DOE. One proposed solution is the application of modular automated chemistry using Standard Laboratory Modules (SLM) to perform Standard Analysis Methods (SAM). The Contaminant Analysis Automation (CAA) Program has developed standards and prototype equipment that will accelerate the development of modular chemistry technology and is transferring this technology to private industry.

  16. 75 FR 17196 - Self-Regulatory Organizations; The Depository Trust Company; Order Granting Approval of a...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-05

    ... Part of the Fast Automated Transfer Program March 30, 2010. I. Introduction On January 19, 2010, The... made unsponsored ADRs eligible for DTC's Fast Automated Securities Transfer Program (``FAST'').\\4\\ \\3... associated with safekeeping, transfer, shipping and insurance costs. \\4\\ FAST was designed to eliminate some...

  17. Advantages of automation in plasma sample preparation prior to HPLC/MS/MS quantification: application to the determination of cilazapril and cilazaprilat in a bioequivalence study.

    PubMed

    Kolocouri, Filomila; Dotsikas, Yannis; Apostolou, Constantinos; Kousoulos, Constantinos; Soumelas, Georgios-Stefanos; Loukas, Yannis L

    2011-01-01

    An HPLC/MS/MS method characterized by complete automation and high throughput was developed for the determination of cilazapril and its active metabolite cilazaprilat in human plasma. All sample preparation and analysis steps were performed by using 2.2 mL 96 deep-well plates, while robotic liquid handling workstations were utilized for all liquid transfer steps, including liquid-liquid extraction. The whole procedure was very fast compared to a manual procedure with vials and no automation. The method also had a very short chromatographic run time of 1.5 min. Sample analysis was performed by RP-HPLC/MS/MS with positive electrospray ionization using multiple reaction monitoring. The calibration curve was linear in the range of 0.500-300 and 0.250-150 ng/mL for cilazapril and cilazaprilat, respectively. The proposed method was fully validated and proved to be selective, accurate, precise, reproducible, and suitable for the determination of cilazapril and cilazaprilat in human plasma. Therefore, it was applied to a bioequivalence study after per os administration of 2.5 mg tablet formulations of cilazapril.

  18. Automated methods for multiplexed pathogen detection.

    PubMed

    Straub, Timothy M; Dockendorff, Brian P; Quiñonez-Díaz, Maria D; Valdez, Catherine O; Shutthanandan, Janani I; Tarasevich, Barbara J; Grate, Jay W; Bruckner-Lea, Cynthia J

    2005-09-01

    Detection of pathogenic microorganisms in environmental samples is a difficult process. Concentration of the organisms of interest also co-concentrates inhibitors of many end-point detection methods, notably, nucleic acid methods. In addition, sensitive, highly multiplexed pathogen detection continues to be problematic. The primary function of the BEADS (Biodetection Enabling Analyte Delivery System) platform is the automated concentration and purification of target analytes from interfering substances, often present in these samples, via a renewable surface column. In one version of BEADS, automated immunomagnetic separation (IMS) is used to separate cells from their samples. Captured cells are transferred to a flow-through thermal cycler where PCR, using labeled primers, is performed. PCR products are then detected by hybridization to a DNA suspension array. In another version of BEADS, cell lysis is performed, and community RNA is purified and directly labeled. Multiplexed detection is accomplished by direct hybridization of the RNA to a planar microarray. The integrated IMS/PCR version of BEADS can successfully purify and amplify 10 E. coli O157:H7 cells from river water samples. Multiplexed PCR assays for the simultaneous detection of E. coli O157:H7, Salmonella, and Shigella on bead suspension arrays was demonstrated for the detection of as few as 100 cells for each organism. Results for the RNA version of BEADS are also showing promising results. Automation yields highly purified RNA, suitable for multiplexed detection on microarrays, with microarray detection specificity equivalent to PCR. Both versions of the BEADS platform show great promise for automated pathogen detection from environmental samples. Highly multiplexed pathogen detection using PCR continues to be problematic, but may be required for trace detection in large volume samples. The RNA approach solves the issues of highly multiplexed PCR and provides "live vs. dead" capabilities. However, sensitivity of the method will need to be improved for RNA analysis to replace PCR.

  19. Automated Methods for Multiplexed Pathogen Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Straub, Tim M.; Dockendorff, Brian P.; Quinonez-Diaz, Maria D.

    2005-09-01

    Detection of pathogenic microorganisms in environmental samples is a difficult process. Concentration of the organisms of interest also co-concentrates inhibitors of many end-point detection methods, notably, nucleic acid methods. In addition, sensitive, highly multiplexed pathogen detection continues to be problematic. The primary function of the BEADS (Biodetection Enabling Analyte Delivery System) platform is the automated concentration and purification of target analytes from interfering substances, often present in these samples, via a renewable surface column. In one version of BEADS, automated immunomagnetic separation (IMS) is used to separate cells from their samples. Captured cells are transferred to a flow-through thermal cyclermore » where PCR, using labeled primers, is performed. PCR products are then detected by hybridization to a DNA suspension array. In another version of BEADS, cell lysis is performed, and community RNA is purified and directly labeled. Multiplexed detection is accomplished by direct hybridization of the RNA to a planar microarray. The integrated IMS/PCR version of BEADS can successfully purify and amplify 10 E. coli O157:H7 cells from river water samples. Multiplexed PCR assays for the simultaneous detection of E. coli O157:H7, Salmonella, and Shigella on bead suspension arrays was demonstrated for the detection of as few as 100 cells for each organism. Results for the RNA version of BEADS are also showing promising results. Automation yields highly purified RNA, suitable for multiplexed detection on microarrays, with microarray detection specificity equivalent to PCR. Both versions of the BEADS platform show great promise for automated pathogen detection from environmental samples. Highly multiplexed pathogen detection using PCR continues to be problematic, but may be required for trace detection in large volume samples. The RNA approach solves the issues of highly multiplexed PCR and provides ''live vs. dead'' capabilities. However, sensitivity of the method will need to be improved for RNA analysis to replace PCR.« less

  20. Effects of Selected Task Performance Criteria at Initiating Adaptive Task Real locations

    NASA Technical Reports Server (NTRS)

    Montgomery, Demaris A.

    2001-01-01

    In the current report various performance assessment methods used to initiate mode transfers between manual control and automation for adaptive task reallocation were tested. Participants monitored two secondary tasks for critical events while actively controlling a process in a fictional system. One of the secondary monitoring tasks could be automated whenever operators' performance was below acceptable levels. Automation of the secondary task and transfer of the secondary task back to manual control were either human- or machine-initiated. Human-initiated transfers were based on the operator's assessment of the current task demands while machine-initiated transfers were based on the operators' performance. Different performance assessment methods were tested in two separate experiments.

  1. Semi-automated 96-well solid-phase extraction and gas chromatography-negative chemical ionization tandem mass spectrometry for the trace analysis of fluprostenol in rat plasma.

    PubMed

    Gauw, R D; Stoffolano, P J; Kuhlenbeck, D L; Patel, V S; Garver, S M; Baker, T R; Wehmeyer, K R

    2000-07-21

    Semi-automated 96-well plate solid-phase extraction (SPE) was used for sample preparation of fluprostenol, a prostaglandin analog, in rat plasma prior to detection by gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS-MS). A liquid handling system was utilized for all aspects of sample handling prior to SPE including transferring of samples into a 96-well format, preparation of standards as well as addition of internal standard to standards, quality control samples and study samples. SPE was performed in a 96-well plate format using octadecylsilane packing and the effluent from the SPE was dried in a custom-made 96-well apparatus. The sample residue was derivatized sequentially with pentafluorobenzylbromide followed by N-methyl-N-trimethylsilyltrifluoroacetamide. The derivatized sample was then analyzed using GC-NCI-MS-MS. The dynamic range for the method was from 7 to 5800 pg/ml with a 0.1-ml plasma sample. The methodology was evaluated over a 4-day period and demonstrated an accuracy of 90-106% with a precision of 2.4-12.9%.

  2. Feedback quantum control of molecular electronic population transfer

    NASA Astrophysics Data System (ADS)

    Bardeen, Christopher J.; Yakovlev, Vladislav V.; Wilson, Kent R.; Carpenter, Scott D.; Weber, Peter M.; Warren, Warren S.

    1997-11-01

    Feedback quantum control, where the sample `teaches' a computer-controlled arbitrary lightform generator to find the optimal light field, is experimentally demonstrated for a molecular system. Femtosecond pulses tailored by a computer-controlled acousto-optic pulse shaper excite fluorescence from laser dye molecules in solution. Fluorescence and laser power are monitored, and the computer uses the experimental data and a genetic algorithm to optimize population transfer from ground to first excited state. Both efficiency (the ratio of excited state population to laser energy) and effectiveness (total excited state population) are optimized. Potential use as an `automated theory tester' is discussed.

  3. Precise turnaround time measurement of laboratory processes using radiofrequency identification technology.

    PubMed

    Mayer, Horst; Brümmer, Jens; Brinkmann, Thomas

    2011-01-01

    To implement Lean Six Sigma in our central laboratory we conducted a project to measure single pre-analytical steps influencing turnaround time (TAT) of emergency department (ED) serum samples. The traditional approach of extracting data from the Laboratory Information System (LIS) for a retrospective calculation of a mean TAT is not suitable. Therefore, we used radiofrequency identification (RFID) chips for real time tracking of individual samples at any pre-analytical step. 1,200 serum tubes were labelled with RFID chips and were provided to the emergency department. 3 RFID receivers were installed in the laboratory: at the outlet of the pneumatic tube system, at the centrifuge, and in the analyser area. In addition, time stamps of sample entry at the automated sample distributor and communication of results from the analyser were collected from LIS. 1,023 labelled serum tubes arrived at our laboratory. 899 RFID tags were used for TAT calculation. The following transfer times were determined (median 95th percentile in min:sec): pneumatic tube system --> centrifuge (01:25/04:48), centrifuge --> sample distributor (14:06/5:33), sample distributor --> analysis system zone (02:39/15:07), analysis system zone --> result communication (12:42/22:21). Total TAT was calculated at 33:19/57:40 min:sec. Manual processes around centrifugation were identified as a major part of TAT with 44%/60% (median/95th percentile). RFID is a robust, easy to use, and error-free technology and not susceptible to interferences in the laboratory environment. With this study design we were able to measure significant variations in a single manual sample transfer process. We showed that TAT is mainly influenced by manual steps around the centrifugation process and we concluded that centrifugation should be integrated in solutions for total laboratory automation.

  4. Validation of an automated solid-phase extraction method for the analysis of 23 opioids, cocaine, and metabolites in urine with ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Ramírez Fernández, María del Mar; Van Durme, Filip; Wille, Sarah M R; di Fazio, Vincent; Kummer, Natalie; Samyn, Nele

    2014-06-01

    The aim of this work was to automate a sample preparation procedure extracting morphine, hydromorphone, oxymorphone, norcodeine, codeine, dihydrocodeine, oxycodone, 6-monoacetyl-morphine, hydrocodone, ethylmorphine, benzoylecgonine, cocaine, cocaethylene, tramadol, meperidine, pentazocine, fentanyl, norfentanyl, buprenorphine, norbuprenorphine, propoxyphene, methadone and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine from urine samples. Samples were extracted by solid-phase extraction (SPE) with cation exchange cartridges using a TECAN Freedom Evo 100 base robotic system, including a hydrolysis step previous extraction when required. Block modules were carefully selected in order to use the same consumable material as in manual procedures to reduce cost and/or manual sample transfers. Moreover, the present configuration included pressure monitoring pipetting increasing pipetting accuracy and detecting sampling errors. The compounds were then separated in a chromatographic run of 9 min using a BEH Phenyl analytical column on a ultra-performance liquid chromatography-tandem mass spectrometry system. Optimization of the SPE was performed with different wash conditions and elution solvents. Intra- and inter-day relative standard deviations (RSDs) were within ±15% and bias was within ±15% for most of the compounds. Recovery was >69% (RSD < 11%) and matrix effects ranged from 1 to 26% when compensated with the internal standard. The limits of quantification ranged from 3 to 25 ng/mL depending on the compound. No cross-contamination in the automated SPE system was observed. The extracted samples were stable for 72 h in the autosampler (4°C). This method was applied to authentic samples (from forensic and toxicology cases) and to proficiency testing schemes containing cocaine, heroin, buprenorphine and methadone, offering fast and reliable results. Automation resulted in improved precision and accuracy, and a minimum operator intervention, leading to safer sample handling and less time-consuming procedures.

  5. A Sample Handling System for Mars Sample Return - Design and Status

    NASA Astrophysics Data System (ADS)

    Allouis, E.; Renouf, I.; Deridder, M.; Vrancken, D.; Gelmi, R.; Re, E.

    2009-04-01

    A mission to return atmosphere and soil samples form the Mars is highly desired by planetary scientists from around the world and space agencies are starting preparation for the launch of a sample return mission in the 2020 timeframe. Such a mission would return approximately 500 grams of atmosphere, rock and soil samples to Earth by 2025. Development of a wide range of new technology will be critical to the successful implementation of such a challenging mission. Technical developments required to realise the mission include guided atmospheric entry, soft landing, sample handling robotics, biological sealing, Mars atmospheric ascent sample rendezvous & capture and Earth return. The European Space Agency has been performing system definition studies along with numerous technology development studies under the framework of the Aurora programme. Within the scope of these activities Astrium has been responsible for defining an overall sample handling architecture in collaboration with European partners (sample acquisition and sample capture, Galileo Avionica; sample containment and automated bio-sealing, Verhaert). Our work has focused on the definition and development of the robotic systems required to move the sample through the transfer chain. This paper presents the Astrium team's high level design for the surface transfer system and the orbiter transfer system. The surface transfer system is envisaged to use two robotic arms of different sizes to allow flexible operations and to enable sample transfer over relatively large distances (~2 to 3 metres): The first to deploy/retract the Drill Assembly used for sample collection, the second for the transfer of the Sample Container (the vessel containing all the collected samples) from the Drill Assembly to the Mars Ascent Vehicle (MAV). The sample transfer actuator also features a complex end-effector for handling the Sample Container. The orbiter transfer system will transfer the Sample Container from the capture mechanism through a bio-sealing system to the Earth Return Capsule (ERC) and has distinctly different requirements from the surface transfer system. The operations required to transfer the samples to the ERC are clearly defined and make use of mechanisms specifically designed for the job rather than robotic arms. Though it is mechanical rather than robotic, the design of the orbiter transfer system is very complex in comparison to most previous missions to fulfil all the scientific and technological requirements. Further mechanisms will be required to lock the samples into the ERC and to close the door at the rear of the ERC through which the samples have been inserted. Having performed this overall definition study, Astrium is now leading the next step of the development of the MSR sample handling: the Mars Surface Sample Transfer and Manipulation project (MSSTM). Organised in two phases, the project will re-evaluate in phase 1 the output of the previous study in the light of new inputs (e.g. addition of a rover) and investigate further the architectures and systems involved in the sample transfer chain while identifying the critical technologies. The second phase of the project will concentrate on the prototyping of a number of these key technologies with the goal of providing an end-to end validation of the surface sample transfer concept.

  6. Automating Initial Guess Generation for High Fidelity Trajectory Optimization Tools

    NASA Technical Reports Server (NTRS)

    Villa, Benjamin; Lantoine, Gregory; Sims, Jon; Whiffen, Gregory

    2013-01-01

    Many academic studies in spaceflight dynamics rely on simplified dynamical models, such as restricted three-body models or averaged forms of the equations of motion of an orbiter. In practice, the end result of these preliminary orbit studies needs to be transformed into more realistic models, in particular to generate good initial guesses for high-fidelity trajectory optimization tools like Mystic. This paper reviews and extends some of the approaches used in the literature to perform such a task, and explores the inherent trade-offs of such a transformation with a view toward automating it for the case of ballistic arcs. Sample test cases in the libration point regimes and small body orbiter transfers are presented.

  7. Combinatorial and high-throughput approaches in polymer science

    NASA Astrophysics Data System (ADS)

    Zhang, Huiqi; Hoogenboom, Richard; Meier, Michael A. R.; Schubert, Ulrich S.

    2005-01-01

    Combinatorial and high-throughput approaches have become topics of great interest in the last decade due to their potential ability to significantly increase research productivity. Recent years have witnessed a rapid extension of these approaches in many areas of the discovery of new materials including pharmaceuticals, inorganic materials, catalysts and polymers. This paper mainly highlights our progress in polymer research by using an automated parallel synthesizer, microwave synthesizer and ink-jet printer. The equipment and methodologies in our experiments, the high-throughput experimentation of different polymerizations (such as atom transfer radical polymerization, cationic ring-opening polymerization and emulsion polymerization) and the automated matrix-assisted laser desorption/ionization time-of-flight mass spectroscopy (MALDI-TOF MS) sample preparation are described.

  8. Fully Automated Centrifugal Microfluidic Device for Ultrasensitive Protein Detection from Whole Blood.

    PubMed

    Park, Yang-Seok; Sunkara, Vijaya; Kim, Yubin; Lee, Won Seok; Han, Ja-Ryoung; Cho, Yoon-Kyoung

    2016-04-16

    Enzyme-linked immunosorbent assay (ELISA) is a promising method to detect small amount of proteins in biological samples. The devices providing a platform for reduced sample volume and assay time as well as full automation are required for potential use in point-of-care-diagnostics. Recently, we have demonstrated ultrasensitive detection of serum proteins, C-reactive protein (CRP) and cardiac troponin I (cTnI), utilizing a lab-on-a-disc composed of TiO2 nanofibrous (NF) mats. It showed a large dynamic range with femto molar (fM) detection sensitivity, from a small volume of whole blood in 30 min. The device consists of several components for blood separation, metering, mixing, and washing that are automated for improved sensitivity from low sample volumes. Here, in the video demonstration, we show the experimental protocols and know-how for the fabrication of NFs as well as the disc, their integration and the operation in the following order: processes for preparing TiO2 NF mat; transfer-printing of TiO2 NF mat onto the disc; surface modification for immune-reactions, disc assembly and operation; on-disc detection and representative results for immunoassay. Use of this device enables multiplexed analysis with minimal consumption of samples and reagents. Given the advantages, the device should find use in a wide variety of applications, and prove beneficial in facilitating the analysis of low abundant proteins.

  9. Automating multistep flow synthesis: approach and challenges in integrating chemistry, machines and logic

    PubMed Central

    Shukla, Chinmay A

    2017-01-01

    The implementation of automation in the multistep flow synthesis is essential for transforming laboratory-scale chemistry into a reliable industrial process. In this review, we briefly introduce the role of automation based on its application in synthesis viz. auto sampling and inline monitoring, optimization and process control. Subsequently, we have critically reviewed a few multistep flow synthesis and suggested a possible control strategy to be implemented so that it helps to reliably transfer the laboratory-scale synthesis strategy to a pilot scale at its optimum conditions. Due to the vast literature in multistep synthesis, we have classified the literature and have identified the case studies based on few criteria viz. type of reaction, heating methods, processes involving in-line separation units, telescopic synthesis, processes involving in-line quenching and process with the smallest time scale of operation. This classification will cover the broader range in the multistep synthesis literature. PMID:28684977

  10. Automated, Ultra-Sterile Solid Sample Handling and Analysis on a Chip

    NASA Technical Reports Server (NTRS)

    Mora, Maria F.; Stockton, Amanda M.; Willis, Peter A.

    2013-01-01

    There are no existing ultra-sterile lab-on-a-chip systems that can accept solid samples and perform complete chemical analyses without human intervention. The proposed solution is to demonstrate completely automated lab-on-a-chip manipulation of powdered solid samples, followed by on-chip liquid extraction and chemical analysis. This technology utilizes a newly invented glass micro-device for solid manipulation, which mates with existing lab-on-a-chip instrumentation. Devices are fabricated in a Class 10 cleanroom at the JPL MicroDevices Lab, and are plasma-cleaned before and after assembly. Solid samples enter the device through a drilled hole in the top. Existing micro-pumping technology is used to transfer milligrams of powdered sample into an extraction chamber where it is mixed with liquids to extract organic material. Subsequent chemical analysis is performed using portable microchip capillary electrophoresis systems (CE). These instruments have been used for ultra-highly sensitive (parts-per-trillion, pptr) analysis of organic compounds including amines, amino acids, aldehydes, ketones, carboxylic acids, and thiols. Fully autonomous amino acid analyses in liquids were demonstrated; however, to date there have been no reports of completely automated analysis of solid samples on chip. This approach utilizes an existing portable instrument that houses optics, high-voltage power supplies, and solenoids for fully autonomous microfluidic sample processing and CE analysis with laser-induced fluorescence (LIF) detection. Furthermore, the entire system can be sterilized and placed in a cleanroom environment for analyzing samples returned from extraterrestrial targets, if desired. This is an entirely new capability never demonstrated before. The ability to manipulate solid samples, coupled with lab-on-a-chip analysis technology, will enable ultraclean and ultrasensitive end-to-end analysis of samples that is orders of magnitude more sensitive than the ppb goal given in the Science Instruments.

  11. PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis.

    PubMed

    Capozzi, Vittorio; Yener, Sine; Khomenko, Iuliia; Farneti, Brian; Cappellin, Luca; Gasperi, Flavia; Scampicchio, Matteo; Biasioli, Franco

    2017-05-11

    Proton Transfer Reaction (PTR), combined with a Time-of-Flight (ToF) Mass Spectrometer (MS) is an analytical approach based on chemical ionization that belongs to the Direct-Injection Mass Spectrometric (DIMS) technologies. These techniques allow the rapid determination of volatile organic compounds (VOCs), assuring high sensitivity and accuracy. In general, PTR-MS requires neither sample preparation nor sample destruction, allowing real time and non-invasive analysis of samples. PTR-MS are exploited in many fields, from environmental and atmospheric chemistry to medical and biological sciences. More recently, we developed a methodology based on coupling PTR-ToF-MS with an automated sampler and tailored data analysis tools, to increase the degree of automation and, consequently, to enhance the potential of the technique. This approach allowed us to monitor bioprocesses (e.g. enzymatic oxidation, alcoholic fermentation), to screen large sample sets (e.g. different origins, entire germoplasms) and to analyze several experimental modes (e.g. different concentrations of a given ingredient, different intensities of a specific technological parameter) in terms of VOC content. Here, we report the experimental protocols exemplifying different possible applications of our methodology: i.e. the detection of VOCs released during lactic acid fermentation of yogurt (on-line bioprocess monitoring), the monitoring of VOCs associated with different apple cultivars (large-scale screening), and the in vivo study of retronasal VOC release during coffee drinking (nosespace analysis).

  12. Automated mass spectrometer analysis system

    NASA Technical Reports Server (NTRS)

    Giffin, Charles E. (Inventor); Kuppermann, Aron (Inventor); Dreyer, William J. (Inventor); Boettger, Heinz G. (Inventor)

    1982-01-01

    An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatilizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vilicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

  13. Automated mass spectrometer analysis system

    NASA Technical Reports Server (NTRS)

    Boettger, Heinz G. (Inventor); Giffin, Charles E. (Inventor); Dreyer, William J. (Inventor); Kuppermann, Aron (Inventor)

    1978-01-01

    An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vidicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

  14. 75 FR 7641 - Self-Regulatory Organizations; The Depository Trust Company; Notice of Filing of Proposed Rule...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-22

    ... Fast Automated Securities Transfer Program February 5, 2010. Pursuant to Section 19(b)(1) of the... American Depositary Receipts (``ADRs'') that are a part of DTC's Fast Automated Securities Transfer Program (``FAST''). II. Self-Regulatory Organization's Statement of the Purpose of, and Statutory Basis for, the...

  15. Does Automated Feedback Improve Writing Quality?

    ERIC Educational Resources Information Center

    Wilson, Joshua; Olinghouse, Natalie G.; Andrada, Gilbert N.

    2014-01-01

    The current study examines data from students in grades 4-8 who participated in a statewide computer-based benchmark writing assessment that featured automated essay scoring and automated feedback. We examined whether the use of automated feedback was associated with gains in writing quality across revisions to an essay, and with transfer effects…

  16. AST: an automated sequence-sampling method for improving the taxonomic diversity of gene phylogenetic trees.

    PubMed

    Zhou, Chan; Mao, Fenglou; Yin, Yanbin; Huang, Jinling; Gogarten, Johann Peter; Xu, Ying

    2014-01-01

    A challenge in phylogenetic inference of gene trees is how to properly sample a large pool of homologous sequences to derive a good representative subset of sequences. Such a need arises in various applications, e.g. when (1) accuracy-oriented phylogenetic reconstruction methods may not be able to deal with a large pool of sequences due to their high demand in computing resources; (2) applications analyzing a collection of gene trees may prefer to use trees with fewer operational taxonomic units (OTUs), for instance for the detection of horizontal gene transfer events by identifying phylogenetic conflicts; and (3) the pool of available sequences is biased towards extensively studied species. In the past, the creation of subsamples often relied on manual selection. Here we present an Automated sequence-Sampling method for improving the Taxonomic diversity of gene phylogenetic trees, AST, to obtain representative sequences that maximize the taxonomic diversity of the sampled sequences. To demonstrate the effectiveness of AST, we have tested it to solve four problems, namely, inference of the evolutionary histories of the small ribosomal subunit protein S5 of E. coli, 16 S ribosomal RNAs and glycosyl-transferase gene family 8, and a study of ancient horizontal gene transfers from bacteria to plants. Our results show that the resolution of our computational results is almost as good as that of manual inference by domain experts, hence making the tool generally useful to phylogenetic studies by non-phylogeny specialists. The program is available at http://csbl.bmb.uga.edu/~zhouchan/AST.php.

  17. AST: An Automated Sequence-Sampling Method for Improving the Taxonomic Diversity of Gene Phylogenetic Trees

    PubMed Central

    Zhou, Chan; Mao, Fenglou; Yin, Yanbin; Huang, Jinling; Gogarten, Johann Peter; Xu, Ying

    2014-01-01

    A challenge in phylogenetic inference of gene trees is how to properly sample a large pool of homologous sequences to derive a good representative subset of sequences. Such a need arises in various applications, e.g. when (1) accuracy-oriented phylogenetic reconstruction methods may not be able to deal with a large pool of sequences due to their high demand in computing resources; (2) applications analyzing a collection of gene trees may prefer to use trees with fewer operational taxonomic units (OTUs), for instance for the detection of horizontal gene transfer events by identifying phylogenetic conflicts; and (3) the pool of available sequences is biased towards extensively studied species. In the past, the creation of subsamples often relied on manual selection. Here we present an Automated sequence-Sampling method for improving the Taxonomic diversity of gene phylogenetic trees, AST, to obtain representative sequences that maximize the taxonomic diversity of the sampled sequences. To demonstrate the effectiveness of AST, we have tested it to solve four problems, namely, inference of the evolutionary histories of the small ribosomal subunit protein S5 of E. coli, 16 S ribosomal RNAs and glycosyl-transferase gene family 8, and a study of ancient horizontal gene transfers from bacteria to plants. Our results show that the resolution of our computational results is almost as good as that of manual inference by domain experts, hence making the tool generally useful to phylogenetic studies by non-phylogeny specialists. The program is available at http://csbl.bmb.uga.edu/~zhouchan/AST.php. PMID:24892935

  18. Automated parking garage system model

    NASA Technical Reports Server (NTRS)

    Collins, E. R., Jr.

    1975-01-01

    A one-twenty-fifth scale model of the key components of an automated parking garage system is described. The design of the model required transferring a vehicle from an entry level, vertically (+Z, -Z), to a storage location at any one of four storage positions (+X, -X, +Y, +Y, -Y) on the storage levels. There are three primary subsystems: (1) a screw jack to provide the vertical motion of the elevator, (2) a cam-driven track-switching device to provide X to Y motion, and (3) a transfer cart to provide horizontal travel and a small amount to vertical motion for transfer to the storage location. Motive power is provided by dc permanent magnet gear motors, one each for the elevator and track switching device and two for the transfer cart drive system (one driving the cart horizontally and the other providing the vertical transfer). The control system, through the use of a microprocessor, provides complete automation through a feedback system which utilizes sensing devices.

  19. High-Throughput Serum 25-Hydroxy Vitamin D Testing with Automated Sample Preparation.

    PubMed

    Stone, Judy

    2016-01-01

    Serum from bar-coded tubes, and then internal standard, are pipetted to 96-well plates with an 8-channel automated liquid handler (ALH). The first precipitation reagent (methanol:ZnSO4) is added and mixed with the 8-channel ALH. A second protein precipitating agent, 1 % formic acid in acetonitrile, is added and mixed with a 96-channel ALH. After a 4-min delay for larger precipitates to settle to the bottom of the plate, the upper 36 % of the precipitate/supernatant mix is transferred with the 96-channel ALH to a Sigma Hybrid SPE(®) plate and vacuumed through for removal of phospholipids and precipitated proteins. The filtrate is collected in a second 96-well plate (collection plate) which is foil-sealed, placed in the autosampler (ALS), and injected into a multiplexed LC-MS/MS system running AB Sciex Cliquid(®) and MPX(®) software. Two Shimadzu LC stacks, with multiplex timing controlled by MPX(®) software, inject alternately to one AB Sciex API-5000 MS/MS using positive atmospheric pressure chemical ionization (APCI) and a 1.87 min water/acetonitrile LC gradient with a 2.1 × 20 mm, 2.7 μm, C18 fused core particle column (Sigma Ascentis Express). LC-MS/MS through put is ~44 samples/h/LC-MS/MS system with dual-LC channel multiplexing. Plate maps are transferred electronically from the ALH and reformatted into LC-MS/MS sample table format using the Data Innovations LLC (DI) Instrument Manager middleware application. Before collection plates are loaded into the ALS, the plate bar code is manually scanned to download the sample table from the DI middleware to the LC-MS/MS. After acquisition-LC-MS/MS data is analyzed with AB Sciex Multiquant(®) software using customized queries, and then results are transferred electronically via a DI interface to the LIS. 2500 samples/day can be extracted by two analysts using four ALHs in 4-6 h. LC-MS/MS analysis of those samples on three dual-channel LC multiplexed LC-MS/MS systems requires 19-21 h and data analysis can be done by two analysts in 4-6 h.

  20. Automated multimodal spectral histopathology for quantitative diagnosis of residual tumour during basal cell carcinoma surgery.

    PubMed

    Boitor, Radu; Kong, Kenny; Shipp, Dustin; Varma, Sandeep; Koloydenko, Alexey; Kulkarni, Kusum; Elsheikh, Somaia; Schut, Tom Bakker; Caspers, Peter; Puppels, Gerwin; van der Wolf, Martin; Sokolova, Elena; Nijsten, T E C; Salence, Brogan; Williams, Hywel; Notingher, Ioan

    2017-12-01

    Multimodal spectral histopathology (MSH), an optical technique combining tissue auto-fluorescence (AF) imaging and Raman micro-spectroscopy (RMS), was previously proposed for detection of residual basal cell carcinoma (BCC) at the surface of surgically-resected skin tissue. Here we report the development of a fully-automated prototype instrument based on MSH designed to be used in the clinic and operated by a non-specialist spectroscopy user. The algorithms for the AF image processing and Raman spectroscopy classification had been first optimised on a manually-operated laboratory instrument and then validated on the automated prototype using skin samples from independent patients. We present results on a range of skin samples excised during Mohs micrographic surgery, and demonstrate consistent diagnosis obtained in repeat test measurement, in agreement with the reference histopathology diagnosis. We also show that the prototype instrument can be operated by clinical users (a skin surgeon and a core medical trainee, after only 1-8 hours of training) to obtain consistent results in agreement with histopathology. The development of the new automated prototype and demonstration of inter-instrument transferability of the diagnosis models are important steps on the clinical translation path: it allows the testing of the MSH technology in a relevant clinical environment in order to evaluate its performance on a sufficiently large number of patients.

  1. Transition to manual: Comparing simulator with on-road control transitions.

    PubMed

    Eriksson, A; Banks, V A; Stanton, N A

    2017-05-01

    Whilst previous research has explored how driver behaviour in simulators may transfer to the open road, there has been relatively little research showing the same transfer within the field of driving automation. As a consequence, most research into human-automation interaction has primarily been carried out in a research laboratory or on closed-circuit test tracks. The aim of this study was to assess whether research into non-critical control transactions in highly automated vehicles performed in driving simulators correlate with road driving conditions. Twenty six drivers drove a highway scenario using an automated driving mode in the simulator and twelve drivers drove on a public motorway in a Tesla Model S with the Autopilot activated. Drivers were asked to relinquish, or resume control from the automation when prompted by the vehicle interface in both the simulator and on road condition. Drivers were generally faster to resume control in the on-road driving condition. However, strong positive correlations were found between the simulator and on road driving conditions for drivers transferring control to and from automation. No significant differences were found with regard to workload, perceived usefulness and satisfaction between the simulator and on-road drives. The results indicate high levels of relative validity of driving simulators as a research tool for automated driving research. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Investigating the feasibility of scale up and automation of human induced pluripotent stem cells cultured in aggregates in feeder free conditions☆

    PubMed Central

    Soares, Filipa A.C.; Chandra, Amit; Thomas, Robert J.; Pedersen, Roger A.; Vallier, Ludovic; Williams, David J.

    2014-01-01

    The transfer of a laboratory process into a manufacturing facility is one of the most critical steps required for the large scale production of cell-based therapy products. This study describes the first published protocol for scalable automated expansion of human induced pluripotent stem cell lines growing in aggregates in feeder-free and chemically defined medium. Cells were successfully transferred between different sites representative of research and manufacturing settings; and passaged manually and using the CompacT SelecT automation platform. Modified protocols were developed for the automated system and the management of cells aggregates (clumps) was identified as the critical step. Cellular morphology, pluripotency gene expression and differentiation into the three germ layers have been used compare the outcomes of manual and automated processes. PMID:24440272

  3. Development of a low-cost, modified resin transfer molding process using elastomeric tooling and automated preform fabrication

    NASA Technical Reports Server (NTRS)

    Doane, William J.; Hall, Ronald G.

    1992-01-01

    This paper describes the design and process development of low-cost structural parts made by a modified resin transfer molding process. Innovative application of elastomeric tooling to increase laminate fiber volume and automated forming of fiber preforms are discussed, as applied to fabrication of a representative section of a cruise missile fuselage.

  4. Technology transfer potential of an automated water monitoring system. [market research

    NASA Technical Reports Server (NTRS)

    Jamieson, W. M.; Hillman, M. E. D.; Eischen, M. A.; Stilwell, J. M.

    1976-01-01

    The nature and characteristics of the potential economic need (markets) for a highly integrated water quality monitoring system were investigated. The technological, institutional and marketing factors that would influence the transfer and adoption of an automated system were studied for application to public and private water supply, public and private wastewater treatment and environmental monitoring of rivers and lakes.

  5. Simultaneous determination of aflatoxin B₁, B₂, G₁, and G₂ in corn powder, edible oil, peanut butter, and soy sauce by liquid chromatography with tandem mass spectrometry utilizing turbulent flow chromatography.

    PubMed

    Fan, Sufang; Li, Qiang; Zhang, Xiaoguang; Cui, Xiaobin; Zhang, Dongsheng; Zhang, Yan

    2015-05-01

    A novel fully automated method based on dual column switching using turbulent flow chromatography followed by liquid chromatography with tandem mass spectrometry was developed for the determination of aflatoxin B1 , B2 , G1 , and G2 in corn powder, edible oil, peanut butter, and soy sauce samples. After ultrasound-assisted extraction, samples were directly injected to the chromatographic system and the analytes were concentrated into the clean-up loading column. Through purge switching, the analytes were transferred to the analytical column for subsequent detection by mass spectrometry. Different types of TurboFlow(TM) columns, transfer flow rate, transfer time were optimized. The limits of detection and quantification of this method ranged between 0.2-2.0 and 0.5-4.0 μg/kg for aflatoxins in different matrixes, respectively. Recoveries of aflatoxins were in range of 83-108.1% for all samples, matrix effects were in range of 34.1-104.7%. The developed method has been successfully applied in the analysis of aflatoxin B1 , B2 , G1 , and G2 in real samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. A practical approach to automate randomized design of experiments for ligand-binding assays.

    PubMed

    Tsoi, Jennifer; Patel, Vimal; Shih, Judy

    2014-03-01

    Design of experiments (DOE) is utilized in optimizing ligand-binding assay by modeling factor effects. To reduce the analyst's workload and error inherent with DOE, we propose the integration of automated liquid handlers to perform the randomized designs. A randomized design created from statistical software was imported into custom macro converting the design into a liquid-handler worklist to automate reagent delivery. An optimized assay was transferred to a contract research organization resulting in a successful validation. We developed a practical solution for assay optimization by integrating DOE and automation to increase assay robustness and enable successful method transfer. The flexibility of this process allows it to be applied to a variety of assay designs.

  7. Automated Data Abstraction of Cardiopulmonary Resuscitation Process Measures for Complete Episodes of Cardiac Arrest Resuscitation.

    PubMed

    Lin, Steve; Turgulov, Anuar; Taher, Ahmed; Buick, Jason E; Byers, Adam; Drennan, Ian R; Hu, Samantha; J Morrison, Laurie

    2016-10-01

    Cardiopulmonary resuscitation (CPR) process measures research and quality assurance has traditionally been limited to the first 5 minutes of resuscitation due to significant costs in time, resources, and personnel from manual data abstraction. CPR performance may change over time during prolonged resuscitations, which represents a significant knowledge gap. Moreover, currently available commercial software output of CPR process measures are difficult to analyze. The objective was to develop and validate a software program to help automate the abstraction and transfer of CPR process measures data from electronic defibrillators for complete episodes of cardiac arrest resuscitation. We developed a software program to facilitate and help automate CPR data abstraction and transfer from electronic defibrillators for entire resuscitation episodes. Using an intermediary Extensible Markup Language export file, the automated software transfers CPR process measures data (electrocardiogram [ECG] number, CPR start time, number of ventilations, number of chest compressions, compression rate per minute, compression depth per minute, compression fraction, and end-tidal CO 2 per minute). We performed an internal validation of the software program on 50 randomly selected cardiac arrest cases with resuscitation durations between 15 and 60 minutes. CPR process measures were manually abstracted and transferred independently by two trained data abstractors and by the automated software program, followed by manual interpretation of raw ECG tracings, treatment interventions, and patient events. Error rates and the time needed for data abstraction, transfer, and interpretation were measured for both manual and automated methods, compared to an additional independent reviewer. A total of 9,826 data points were each abstracted by the two abstractors and by the software program. Manual data abstraction resulted in a total of six errors (0.06%) compared to zero errors by the software program. The mean ± SD time measured per case for manual data abstraction was 20.3 ± 2.7 minutes compared to 5.3 ± 1.4 minutes using the software program (p = 0.003). We developed and validated an automated software program that efficiently abstracts and transfers CPR process measures data from electronic defibrillators for complete cardiac arrest episodes. This software will enable future cardiac arrest studies and quality assurance programs to evaluate the impact of CPR process measures during prolonged resuscitations. © 2016 by the Society for Academic Emergency Medicine.

  8. Evaluation of an automated ultraviolet-C light disinfection device and patient hand hygiene for reduction of pathogen transfer from interactive touchscreen computer kiosks.

    PubMed

    Alhmidi, Heba; Cadnum, Jennifer L; Piedrahita, Christina T; John, Amrita R; Donskey, Curtis J

    2018-04-01

    Touchscreens are a potential source of pathogen transmission. In our facility, patients and visitors rarely perform hand hygiene after using interactive touchscreen computer kiosks. An automated ultraviolet-C touchscreen disinfection device was effective in reducing bacteriophage MS2, bacteriophage ϕX174, methicillin-resistant Staphylococcus aureus, and Clostridium difficile spores inoculated onto a touchscreen. In simulations, an automated ultraviolet-C touchscreen disinfection device alone or in combination with hand hygiene reduced transfer of the viruses from contaminated touchscreens to fingertips. Published by Elsevier Inc.

  9. Automatic liquid handling for life science: a critical review of the current state of the art.

    PubMed

    Kong, Fanwei; Yuan, Liang; Zheng, Yuan F; Chen, Weidong

    2012-06-01

    Liquid handling plays a pivotal role in life science laboratories. In experiments such as gene sequencing, protein crystallization, antibody testing, and drug screening, liquid biosamples frequently must be transferred between containers of varying sizes and/or dispensed onto substrates of varying types. The sample volumes are usually small, at the micro- or nanoliter level, and the number of transferred samples can be huge when investigating large-scope combinatorial conditions. Under these conditions, liquid handling by hand is tedious, time-consuming, and impractical. Consequently, there is a strong demand for automated liquid-handling methods such as sensor-integrated robotic systems. In this article, we survey the current state of the art in automatic liquid handling, including technologies developed by both industry and research institutions. We focus on methods for dealing with small volumes at high throughput and point out challenges for future advancements.

  10. Materials for Heated Head Automated Thermoplastic Tape Placement

    NASA Technical Reports Server (NTRS)

    Jensen, Brian J.; Kinney, Megan C.; Cano, Roberto J.; Grimsley, Brian W.

    2012-01-01

    NASA Langley Research Center (LaRC) is currently pursuing multiple paths to develop out of autoclave (OOA) polymeric composite materials and processes. Polymeric composite materials development includes the synthesis of new and/or modified thermosetting and thermoplastic matrix resins designed for specific OOA processes. OOA processes currently under investigation include vacuum bag only (VBO) prepreg/composite fabrication, resin transfer molding (RTM), vacuum assisted resin transfer molding (VARTM) and heated head automated thermoplastic tape placement (HHATP). This paper will discuss the NASA Langley HHATP facility and capabilities and recent work on characterizing thermoplastic tape quality and requirements for quality part production. Samples of three distinct versions of APC-2 (AS4/PEEK) thermoplastic dry tape were obtained from two materials vendors, TENCATE, Inc. and CYTEC Engineered Materials** (standard grade and an experimental batch). Random specimens were taken from each of these samples and subjected to photo-microscopy and surface profilometry. The CYTEC standard grade of APC-2 tape had the most voids and splits and the highest surface roughness and/or waviness. Since the APC-2 tape is composed of a thermoplastic matrix, it offers the flexibility of reprocessing to improve quality, and thereby improve final quality of HHATP laminates. Discussions will also include potential research areas and future work that is required to advance the state of the art in the HHATP process for composite fabrication.

  11. Automated clean-up, separation and detection of polycyclic aromatic hydrocarbons in particulate matter extracts from urban dust and diesel standard reference materials using a 2D-LC/2D-GC system.

    PubMed

    Ahmed, Trifa M; Lim, Hwanmi; Bergvall, Christoffer; Westerholm, Roger

    2013-10-01

    A multidimensional, on-line coupled liquid chromatographic/gas chromatographic system was developed for the quantification of polycyclic aromatic hydrocarbons (PAHs). A two-dimensional liquid chromatographic system (2D-liquid chromatography (LC)), with three columns having different selectivities, was connected on-line to a two-dimensional gas chromatographic system (2D-gas chromatography (GC)). Samples were cleaned up by combining normal elution and column back-flush of the LC columns to selectively remove matrix constituents and isolate well-defined, PAH enriched fractions. Using this system, the sequential removal of polar, mono/diaromatic, olefinic and alkane compounds from crude extracts was achieved. The LC/GC coupling was performed using a fused silica transfer line into a programmable temperature vaporizer (PTV) GC injector. Using the PTV in the solvent vent mode, excess solvent was removed and the enriched PAH sample extract was injected into the GC. The 2D-GC setup consisted of two capillary columns with different stationary phase selectivities. Heart-cutting of selected PAH compounds in the first GC column (first dimension) and transfer of these to the second GC column (second dimension) increased the baseline resolutions of closely eluting PAHs. The on-line system was validated using the standard reference materials SRM 1649a (urban dust) and SRM 1975 (diesel particulate extract). The PAH concentrations measured were comparable to the certified values and the fully automated LC/GC system performed the clean-up, separation and detection of PAHs in 16 extracts in less than 24 h. The multidimensional, on-line 2D-LC/2D-GC system eliminated manual handling of the sample extracts and minimised the risk of sample loss and contamination, while increasing accuracy and precision.

  12. 12 CFR 205.16 - Disclosures at automated teller machines.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 2 2011-01-01 2011-01-01 false Disclosures at automated teller machines. 205.16 Section 205.16 Banks and Banking FEDERAL RESERVE SYSTEM BOARD OF GOVERNORS OF THE FEDERAL RESERVE SYSTEM ELECTRONIC FUND TRANSFERS (REGULATION E) § 205.16 Disclosures at automated teller machines. (a...

  13. Cargo Transfer operations

    NASA Image and Video Library

    2014-08-21

    ISS040-E-103985 (21 Aug. 2014) --- NASA astronaut Steve Swanson, Expedition 40 commander, is pictured during cargo transfer operations in the "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5) currently docked with the International Space Station.

  14. CRADA Payment Options | NCI Technology Transfer Center | TTC

    Cancer.gov

    NCI TTC CRADA PAYMENT OPTIONS: Electronic Payments by Wire Transfer via Fedwire, Mail a check to the Institute or Center, or Automated Clearing House (ACH)/Electronic Funds Transfer (ETF) payments via Pay.gov (NCI ONLY).

  15. Fully automated method for the liquid chromatographic determination of cyproterone acetate in plasma using restricted access material for sample pre-treatment.

    PubMed

    Christiaens, B; Chiap, P; Rbeida, O; Cello, D; Crommen, J; Hubert, Ph

    2003-09-25

    A new fully automated method for the quantitative analysis of an antiandrogenic substance, cyproterone acetate (CPA), in plasma samples has been developed using on-line solid-phase extraction (SPE) prior to the determination by reversed-phase liquid chromatography (LC). The automated method was based on the use of a precolumn packed with an internal-surface reversed-phase packing material (LiChrospher RP-4 ADS) for sample clean-up coupled to LC analysis on an octadecyl stationary phase using a column-switching system. A 200-microL volume of plasma sample was injected directly on the precolumn packed with restricted access material using a mixture of water-acetonitrile (90:10, v/v) as washing liquid. The analyte was then eluted in the back-flush mode with the LC mobile phase which consisted of a mixture of phosphate buffer, pH 7.0-acetonitrile (54:46, v/v). The elution profiles of CPA and blank plasma samples on the precolumn and the time needed for analyte transfer from the precolumn to the analytical column were determined. Different compositions of washing liquid and mobile phase were tested to reduce the interference of plasma endogenous components. UV detection was achieved at 280 nm. Finally, the developed method was validated using a new approach, namely the application of the accuracy profile based on the interval confidence at 90% of the total measurement error (bias+standard deviation). The limit of quantification of cyproterone acetate in plasma was determined at 15 ng mL(-1). The validated method should be applicable to the determination of CPA in patients treated by at least 50 mg day(-1).

  16. A Novel Method for Analysis of Dissolved Inorganic Carbon Concentration and δ13C by Cavity Ring-Down Spectroscopy

    NASA Astrophysics Data System (ADS)

    Smith, E.; Gonneea, M. E.; Boze, L. G.; Casso, M.; Pohlman, J.

    2017-12-01

    Dissolved inorganic carbon (DIC) is the largest pool of carbon in the oceans and is where about half of anthropogenic carbon dioxide (CO2) emissions are being sequestered. Determining the concentration and stable carbon isotopic content (δ13C) of DIC allows us to delineate carbon sources that contribute to marine DIC. A simple and reliable method for measuring DIC concentration and δ13C can be used to apportion contributions from external sources and identify effects from biogeochemical reactions that contribute or remove DIC. The U.S. Geological Survey has developed a discrete sample analysis module (DSAM) that interfaces to a Picarro G-2201i cavity ring-down spectrometer (CRDS, Picarro Inc.) to analyze CO2 and methane concentrations and δ13C from discrete gas samples. In this study, we adapted the USGS DSAM-CRDS analysis system to include an AutoMate prep device (Automate FX, Inc.) for analysis of DIC concentration and δ13C from aqueous samples. The Automate prep device was modified to deliver CO2 extracted from DIC to the DSAM, which conditions and transfers the gas to the CRDS. LabVIEW software (National Instruments) triggers the Automate Prep device, controls the DSAM and collects data from the CRDS. CO2 mass concentration data are obtained by numerical integration of the CO2 volumetric concentrations output by the CRDS and subsequent comparison to standard materials. CO2 carbon isotope values from the CRDS (iCO2) are converted to δ13C values using a slope and offset correction calibration procedure. The system design and operation was optimized using sodium bicarbonate (NaHCO3) standards and a certified reference material. Surface water and pore water samples collected from Sage Lot Pond, a salt marsh in Cape Cod MA, have been analyzed for concentration by coulometry and δ13C by isotope ratio mass spectrometry and will be used to validate the DIC-DSAM-CRDS method for field applications.

  17. Automated ground-water monitoring with Robowell: case studies and potential applications

    NASA Astrophysics Data System (ADS)

    Granato, Gregory E.; Smith, Kirk P.

    2002-02-01

    Robowell is an automated system and method for monitoring ground-water quality. Robowell meets accepted manual- sampling protocols without high labor and laboratory costs. Robowell periodically monitors and records water-quality properties and constituents in ground water by pumping a well or multilevel sampler until one or more purge criteria have been met. A record of frequent water-quality measurements from a monitoring site can indicate changes in ground-water quality and can provide a context for the interpretation of laboratory data from discrete samples. Robowell also can communicate data and system performance through a remote communication link. Remote access to ground-water data enables the user to monitor conditions and optimize manual sampling efforts. Six Robowell prototypes have successfully monitored ground-water quality during all four seasons of the year under different hydrogeologic conditions, well designs, and geochemical environments. The U.S. Geological Survey is seeking partners for research with robust and economical water-quality monitoring instruments designed to measure contaminants of concern in conjunction with the application and commercialization of the Robowell technology. Project publications and information about technology transfer opportunities are available on the Internet at URL http://ma.water.usgs.gov/automon/

  18. Semiautomated Sample Preparation for Protein Stability and Formulation Screening via Buffer Exchange.

    PubMed

    Ying, William; Levons, Jaquan K; Carney, Andrea; Gandhi, Rajesh; Vydra, Vicky; Rubin, A Erik

    2016-06-01

    A novel semiautomated buffer exchange process workflow was developed to enable efficient early protein formulation screening. An antibody fragment protein, BMSdab, was used to demonstrate the workflow. The process afforded 60% to 80% cycle time and scientist time savings and significant material efficiencies. These efficiencies ultimately facilitated execution of this stability work earlier in the drug development process, allowing this tool to inform the developability of potential candidates for development from a formulation perspective. To overcome the key technical challenges, the protein solution was buffer-exchanged by centrifuge filtration into formulations for stability screening in a 96-well plate with an ultrafiltration membrane, leveraging automated liquid handling and acoustic volume measurements to allow several cycles of exchanges. The formulations were transferred into a vacuum manifold and sterile filtered into a rack holding 96 glass vials. The vials were sealed with a capmat of individual caps and placed in stability stations. Stability of the samples prepared by this process and by the standard process was demonstrated to be comparable. This process enabled screening a number of formulations of a protein at an early pharmaceutical development stage with a short sample preparation time. © 2015 Society for Laboratory Automation and Screening.

  19. Automated ground-water monitoring with robowell-Case studies and potential applications

    USGS Publications Warehouse

    Granato, G.E.; Smith, K.P.; ,

    2001-01-01

    Robowell is an automated system and method for monitoring ground-water quality. Robowell meets accepted manual-sampling protocols without high labor and laboratory costs. Robowell periodically monitors and records water-quality properties and constituents in ground water by pumping a well or multilevel sampler until one or more purge criteria have been met. A record of frequent water-quality measurements from a monitoring site can indicate changes in ground-water quality and can provide a context for the interpretation of laboratory data from discrete samples. Robowell also can communicate data and system performance through a remote communication link. Remote access to ground-water data enables the user to monitor conditions and optimize manual sampling efforts. Six Robowell prototypes have successfully monitored ground-water quality during all four seasons of the year under different hydrogeologic conditions, well designs, and geochemical environments. The U.S. Geological Survey is seeking partners for research with robust and economical water-quality monitoring instruments designed to measure contaminants of concern in conjunction with the application and commercialization of the Robowell technology. Project publications and information about technology transfer opportunities are available on the Internet at URL http://ma.water.usgs.gov/automon/.

  20. Fast automated dual-syringe based dispersive liquid-liquid microextraction coupled with gas chromatography-mass spectrometry for the determination of polycyclic aromatic hydrocarbons in environmental water samples.

    PubMed

    Guo, Liang; Tan, Shufang; Li, Xiao; Lee, Hian Kee

    2016-03-18

    An automated procedure, combining low density solvent based solvent demulsification dispersive liquid-liquid microextraction (DLLME) with gas chromatography-mass spectrometry analysis, was developed for the determination of polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. Capitalizing on a two-rail commercial autosampler, fast solvent transfer using a large volume syringe dedicated to the DLLME process, and convenient extract collection using a small volume microsyringe for better GC performance were enabled. Extraction parameters including the type and volume of extraction solvent, the type and volume of dispersive solvent and demulsification solvent, extraction and demulsification time, and the speed of solvent injection were investigated and optimized. Under the optimized conditions, the linearity ranged from 0.1 to 50 μg/L, 0.2 to 50 μg/L, and 0.5 to 50 μg/L, depending on the analytes. Limits of detection were determined to be between 0.023 and 0.058 μg/L. The method was applied to determine PAHs in environmental water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Managing protected health information in distributed research network environments: automated review to facilitate collaboration.

    PubMed

    Bredfeldt, Christine E; Butani, Amy; Padmanabhan, Sandhyasree; Hitz, Paul; Pardee, Roy

    2013-03-22

    Multi-site health sciences research is becoming more common, as it enables investigation of rare outcomes and diseases and new healthcare innovations. Multi-site research usually involves the transfer of large amounts of research data between collaborators, which increases the potential for accidental disclosures of protected health information (PHI). Standard protocols for preventing release of PHI are extremely vulnerable to human error, particularly when the shared data sets are large. To address this problem, we developed an automated program (SAS macro) to identify possible PHI in research data before it is transferred between research sites. The macro reviews all data in a designated directory to identify suspicious variable names and data patterns. The macro looks for variables that may contain personal identifiers such as medical record numbers and social security numbers. In addition, the macro identifies dates and numbers that may identify people who belong to small groups, who may be identifiable even in the absences of traditional identifiers. Evaluation of the macro on 100 sample research data sets indicated a recall of 0.98 and precision of 0.81. When implemented consistently, the macro has the potential to streamline the PHI review process and significantly reduce accidental PHI disclosures.

  2. Automated semantic indexing of figure captions to improve radiology image retrieval.

    PubMed

    Kahn, Charles E; Rubin, Daniel L

    2009-01-01

    We explored automated concept-based indexing of unstructured figure captions to improve retrieval of images from radiology journals. The MetaMap Transfer program (MMTx) was used to map the text of 84,846 figure captions from 9,004 peer-reviewed, English-language articles to concepts in three controlled vocabularies from the UMLS Metathesaurus, version 2006AA. Sampling procedures were used to estimate the standard information-retrieval metrics of precision and recall, and to evaluate the degree to which concept-based retrieval improved image retrieval. Precision was estimated based on a sample of 250 concepts. Recall was estimated based on a sample of 40 concepts. The authors measured the impact of concept-based retrieval to improve upon keyword-based retrieval in a random sample of 10,000 search queries issued by users of a radiology image search engine. Estimated precision was 0.897 (95% confidence interval, 0.857-0.937). Estimated recall was 0.930 (95% confidence interval, 0.838-1.000). In 5,535 of 10,000 search queries (55%), concept-based retrieval found results not identified by simple keyword matching; in 2,086 searches (21%), more than 75% of the results were found by concept-based search alone. Concept-based indexing of radiology journal figure captions achieved very high precision and recall, and significantly improved image retrieval.

  3. NASA Tech Briefs, December 2006

    NASA Technical Reports Server (NTRS)

    2006-01-01

    Topic include: Inferring Gear Damage from Oil-Debris and Vibration Data; Forecasting of Storm-Surge Floods Using ADCIRC and Optimized DEMs; User Interactive Software for Analysis of Human Physiological Data; Representation of Serendipitous Scientific Data; Automatic Locking of Laser Frequency to an Absorption Peak; Self-Passivating Lithium/Solid Electrolyte/Iodine Cells; Four-Quadrant Analog Multipliers Using G4-FETs; Noise Source for Calibrating a Microwave Polarimeter; Hybrid Deployable Foam Antennas and Reflectors; Coating MCPs with AlN and GaN; Domed, 40-cm-Diameter Ion Optics for an Ion Thruster; Gesture-Controlled Interfaces for Self-Service Machines; Dynamically Alterable Arrays of Polymorphic Data Types; Identifying Trends in Deep Space Network Monitor Data; Predicting Lifetime of a Thermomechanically Loaded Component; Partial Automation of Requirements Tracing; Automated Synthesis of Architecture of Avionic Systems; SSRL Emergency Response Shore Tool; Wholly Aromatic Ether-Imides as n-Type Semiconductors; Carbon-Nanotube-Carpet Heat-Transfer Pads; Pulse-Flow Microencapsulation System; Automated Low-Gravitation Facility Would Make Optical Fibers; Alignment Cube with One Diffractive Face; Graphite Composite Booms with Integral Hinges; Tool for Sampling Permafrost on a Remote Planet; and Special Semaphore Scheme for UHF Spacecraft Communications.

  4. Human Factors in the Automated Highway System: Transferring Control to the Driver

    DOT National Transportation Integrated Search

    1995-10-01

    Driver capabilities and limitations must be considered to ensure successful implementation of the Automated Highway System (AHS). Human factors investigations of driver performance characteristics provide the basis for determining system design confi...

  5. Automated Protist Analysis of Complex Samples: Recent Investigations Using Motion and Thresholding

    DTIC Science & Technology

    2012-01-01

    Report No: CG-D-15-13 Automated Protist Analysis of Complex Samples: Recent Investigations Using Motion and Thresholding...Distribution Statement A: Approved for public release; distribution is unlimited. January 2012 Automated Protist Analysis of Complex Samples...Chelsea Street New London, CT 06320 Automated Protist Analysis of Complex Samples iii UNCLAS//PUBLIC | CG-926 R&DC | B. Nelson, et al

  6. Expedition 17 Automated Transfer Vehicle (ATV) Undocking

    NASA Image and Video Library

    2008-09-05

    ISS017-E-015468 (5 Sept. 2008) --- Backdropped by the blackness of space, European Space Agency's (ESA) "Jules Verne" Automated Transfer Vehicle (ATV) begins its relative separation from the International Space Station. The ATV undocked from the aft port of the Zvezda Service Module at 4:29 p.m. (CDT) on Sept. 5, 2008 and was placed in a parking orbit for three weeks, scheduled to be deorbited on Sept. 29 when lighting conditions are correct for an ESA imagery experiment of reentry.

  7. Expedition 17 Automated Transfer Vehicle (ATV) Undocking

    NASA Image and Video Library

    2008-09-05

    ISS017-E-015496 (5 Sept. 2008) --- Backdropped by a blanket of clouds, European Space Agency's (ESA) "Jules Verne" Automated Transfer Vehicle (ATV) continues its relative separation from the International Space Station. The ATV undocked from the aft port of the Zvezda Service Module at 4:29 p.m. (CDT) on Sept. 5, 2008 and was placed in a parking orbit for three weeks, scheduled to be deorbited on Sept. 29 when lighting conditions are correct for an ESA imagery experiment of reentry.

  8. Expedition 17 Automated Transfer Vehicle (ATV) Undocking

    NASA Image and Video Library

    2008-09-05

    ISS017-E-015451 (5 Sept. 2008) --- Backdropped by Earth's horizon and the blackness of space, European Space Agency's (ESA) "Jules Verne" Automated Transfer Vehicle (ATV) begins its relative separation from the International Space Station. The ATV undocked from the aft port of the Zvezda Service Module at 4:29 p.m. (CDT) on Sept. 5, 2008 and was placed in a parking orbit for three weeks, scheduled to be deorbited on Sept. 29 when lighting conditions are correct for an ESA imagery experiment of reentry.

  9. Expedition 17 Automated Transfer Vehicle (ATV) Undocking

    NASA Image and Video Library

    2008-09-05

    ISS017-E-015446 (5 Sept. 2008) --- Backdropped by the blackness of space, European Space Agency's (ESA) "Jules Verne" Automated Transfer Vehicle (ATV) begins its relative separation from the International Space Station. The ATV undocked from the aft port of the Zvezda Service Module at 4:29 p.m. (CDT) on Sept. 5, 2008 and was placed in a parking orbit for three weeks, scheduled to be deorbited on Sept. 29 when lighting conditions are correct for an ESA imagery experiment of reentry.

  10. 76 FR 20061 - Self-Regulatory Organizations; The Depository Trust Company; Order Granting Approval of a...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-11

    ... Relating to the Requirement To Maintain a Balance Certificate in the Fast Automated Securities Transfer... transfer agents'') hold DTC securities in the form of balance certificates.\\4\\ The balance certificates are... issue for which the FAST transfer agent acts as transfer agent. The Balance Certificate Agreement is...

  11. Autovalidation and automation of the postanalytical phase of routine hematology and coagulation analyses in a university hospital laboratory.

    PubMed

    Mlinaric, Ana; Milos, Marija; Coen Herak, Désirée; Fucek, Mirjana; Rimac, Vladimira; Zadro, Renata; Rogic, Dunja

    2018-02-23

    The need to satisfy high-throughput demands for laboratory tests continues to be a challenge. Therefore, we aimed to automate postanalytical phase in hematology and coagulation laboratory by autovalidation of complete blood count (CBC) and routine coagulation test results (prothrombin time [PT], international normalized ratio [PT-INR], activated partial thromboplastin time [APTT], fibrinogen, antithrombin activity [AT] and thrombin time [TT]). Work efficacy and turnaround time (TAT) before and after implementation of automated solutions will be compared. Ordering panels tailored to specific patient populations were implemented. Rerun and reflex testing rules were set in the respective analyzers' software (Coulter DxH Connectivity 1601, Beckman Coulter, FL, USA; AutoAssistant, Siemens Healthcare Diagnostics, Germany), and sample status information was transferred into the laboratory information system. To evaluate if the automation improved TAT and efficacy, data from manually verified results in September and October of 2015 were compared with the corresponding period in 2016 when autovalidation was implemented. Autovalidation rates of 63% for CBC and 65% for routine coagulation test results were achieved. At the TAT of 120 min, the percentage of reported results increased substantially for all analyzed tests, being above 90% for CBC, PT, PT-INR and fibrinogen and 89% for APTT. This output was achieved with three laboratory technicians less compared with the period when the postanalytical phase was not automated. Automation allowed optimized laboratory workflow for specific patient populations, thereby ensuring standardized results reporting. Autovalidation of test results proved to be an efficient tool for improvement of laboratory work efficacy and TAT.

  12. Open tubular lab-on-column/mass spectrometry for targeted proteomics of nanogram sample amounts.

    PubMed

    Hustoft, Hanne Kolsrud; Vehus, Tore; Brandtzaeg, Ole Kristian; Krauss, Stefan; Greibrokk, Tyge; Wilson, Steven Ray; Lundanes, Elsa

    2014-01-01

    A novel open tubular nanoproteomic platform featuring accelerated on-line protein digestion and high-resolution nano liquid chromatography mass spectrometry (LC-MS) has been developed. The platform features very narrow open tubular columns, and is hence particularly suited for limited sample amounts. For enzymatic digestion of proteins, samples are passed through a 20 µm inner diameter (ID) trypsin + endoproteinase Lys-C immobilized open tubular enzyme reactor (OTER). Resulting peptides are subsequently trapped on a monolithic pre-column and transferred on-line to a 10 µm ID porous layer open tubular (PLOT) liquid chromatography LC separation column. Wnt/ß-catenein signaling pathway (Wnt-pathway) proteins of potentially diagnostic value were digested+detected in targeted-MS/MS mode in small cell samples and tumor tissues within 120 minutes. For example, a potential biomarker Axin1 was identifiable in just 10 ng of sample (protein extract of ∼1,000 HCT15 colon cancer cells). In comprehensive mode, the current OTER-PLOT set-up could be used to identify approximately 1500 proteins in HCT15 cells using a relatively short digestion+detection cycle (240 minutes), outperforming previously reported on-line digestion/separation systems. The platform is fully automated utilizing common commercial instrumentation and parts, while the reactor and columns are simple to produce and have low carry-over. These initial results point to automated solutions for fast and very sensitive MS based proteomics, especially for samples of limited size.

  13. Manual versus automated blood sampling: impact of repeated blood sampling on stress parameters and behavior in male NMRI mice

    PubMed Central

    Kalliokoski, Otto; Sørensen, Dorte B; Hau, Jann; Abelson, Klas S P

    2014-01-01

    Facial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups. Plasma corticosterone levels of mice subjected to tail blood sampling were also elevated, although less significantly. Mice subjected to automated blood sampling were less affected with regard to the parameters measured, and expressed less anxious behavior. We conclude that repeated blood sampling by automated blood sampling and from the tail vein is less stressful than cheek blood sampling. The choice between automated blood sampling and tail blood sampling should be based on the study requirements, the resources of the laboratory and skills of the staff. PMID:24958546

  14. Automated observatory in Antarctica: real-time data transfer on constrained networks in practice

    NASA Astrophysics Data System (ADS)

    Bracke, Stephan; Gonsette, Alexandre; Rasson, Jean; Poncelet, Antoine; Hendrickx, Olivier

    2017-08-01

    In 2013 a project was started by the geophysical centre in Dourbes to install a fully automated magnetic observatory in Antarctica. This isolated place comes with specific requirements: unmanned station during 6 months, low temperatures with extreme values down to -50 °C, minimum power consumption and satellite bandwidth limited to 56 Kbit s-1. The ultimate aim is to transfer real-time magnetic data every second: vector data from a LEMI-25 vector magnetometer, absolute F measurements from a GEM Systems scalar proton magnetometer and absolute magnetic inclination-declination (DI) measurements (five times a day) with an automated DI-fluxgate magnetometer. Traditional file transfer protocols (for instance File Transfer Protocol (FTP), email, rsync) show severe limitations when it comes to real-time capability. After evaluation of pro and cons of the available real-time Internet of things (IoT) protocols and seismic software solutions, we chose to use Message Queuing Telemetry Transport (MQTT) and receive the 1 s data with a negligible latency cost and no loss of data. Each individual instrument sends the magnetic data immediately after capturing, and the data arrive approximately 300 ms after being sent, which corresponds with the normal satellite latency.

  15. The cobas p 630 instrument: a dedicated pre-analytic solution to optimize COBAS® AmpliPrep/COBAS® TaqMan® system workflow and turn-around-time.

    PubMed

    Vallefuoco, L; Sorrentino, R; Spalletti Cernia, D; Colucci, G; Portella, G

    2012-12-01

    The cobas p 630, a fully automated pre-analytical instrument for primary tube handling recently introduced to complete the Cobas(®) TaqMan systems portfolio, was evaluated in conjunction with: the COBAS(®) AmpliPrep/COBAS(®) TaqMan HBV Test, v2.0, COBAS(®) AmpliPrep/COBAS(®) TaqMan HCV Test, v1.0 and COBAS(®) AmpliPrep/COBAS(®) TaqMan HIV Test, v2.0. The instrument performance in transferring samples from primary to secondary tubes, its impact in improving COBAS(®) AmpliPrep/COBAS(®) TaqMan workflow and hands-on reduction and the risk of possible cross-contamination were assessed. Samples from 42 HBsAg positive, 42 HCV and 42 HIV antibody (Ab) positive patients as well as 21 healthy blood donors were processed with or without automated primary tubes. HIV, HCV and HBsAg positive samples showed a correlation index of 0.999, 0.987 and of 0.994, respectively. To assess for cross-contamination, high titer HBV DNA positive samples, HCV RNA and HIV RNA positive samples were distributed in the cobas p 630 in alternate tube positions, adjacent to negative control samples within the same rack. None of the healthy donor samples showed any reactivity. Based on these results, the cobas p 630 can improve workflow and sample tracing in laboratories performing molecular tests, and reduce turnaround time, errors, and risks. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Distributed deep learning networks among institutions for medical imaging.

    PubMed

    Chang, Ken; Balachandar, Niranjan; Lam, Carson; Yi, Darvin; Brown, James; Beers, Andrew; Rosen, Bruce; Rubin, Daniel L; Kalpathy-Cramer, Jayashree

    2018-03-29

    Deep learning has become a promising approach for automated support for clinical diagnosis. When medical data samples are limited, collaboration among multiple institutions is necessary to achieve high algorithm performance. However, sharing patient data often has limitations due to technical, legal, or ethical concerns. In this study, we propose methods of distributing deep learning models as an attractive alternative to sharing patient data. We simulate the distribution of deep learning models across 4 institutions using various training heuristics and compare the results with a deep learning model trained on centrally hosted patient data. The training heuristics investigated include ensembling single institution models, single weight transfer, and cyclical weight transfer. We evaluated these approaches for image classification in 3 independent image collections (retinal fundus photos, mammography, and ImageNet). We find that cyclical weight transfer resulted in a performance that was comparable to that of centrally hosted patient data. We also found that there is an improvement in the performance of cyclical weight transfer heuristic with a high frequency of weight transfer. We show that distributing deep learning models is an effective alternative to sharing patient data. This finding has implications for any collaborative deep learning study.

  17. Combined Atomic Force Microscope-Based Topographical Imaging and Nanometer Scale Resolved Proximal Probe Thermal Desorption/Electrospray Ionization-Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ovchinnikova, Olga S; Nikiforov, Maxim; Bradshaw, James A

    2011-01-01

    Nanometer scale proximal probe thermal desorption/electrospray ionization mass spectrometry (TD/ESI-MS) was demonstrated for molecular surface sampling of caffeine from a thin film using a 30 nm diameter nano-thermal analysis (nano-TA) probe tip in an atomic force microscope (AFM) coupled via a vapor transfer line and ESI interface to a MS detection platform. Using a probe temperature of 350 C and a spot sampling time of 30 s, conical desorption craters 250 nm in diameter and 100 nm deep were created as shown through subsequent topographical imaging of the surface within the same system. Automated sampling of a 5 x 2more » array of spots, with 2 m spacing between spots, and real time selective detection of the desorbed caffeine using tandem mass spectrometry was also demonstrated. Estimated from the crater volume (~2x106 nm3), only about 10 amol (2 fg) of caffeine was liberated from each thermal desorption crater in the thin film. These results illustrate a relatively simple experimental setup and means to acquire in automated fashion sub-micrometer scale spatial sampling resolution and mass spectral detection of materials amenable to TD. The ability to achieve MS-based chemical imaging with 250 nm scale spatial resolution with this system is anticipated.« less

  18. Automated Semantic Indexing of Figure Captions to Improve Radiology Image Retrieval

    PubMed Central

    Kahn, Charles E.; Rubin, Daniel L.

    2009-01-01

    Objective We explored automated concept-based indexing of unstructured figure captions to improve retrieval of images from radiology journals. Design The MetaMap Transfer program (MMTx) was used to map the text of 84,846 figure captions from 9,004 peer-reviewed, English-language articles to concepts in three controlled vocabularies from the UMLS Metathesaurus, version 2006AA. Sampling procedures were used to estimate the standard information-retrieval metrics of precision and recall, and to evaluate the degree to which concept-based retrieval improved image retrieval. Measurements Precision was estimated based on a sample of 250 concepts. Recall was estimated based on a sample of 40 concepts. The authors measured the impact of concept-based retrieval to improve upon keyword-based retrieval in a random sample of 10,000 search queries issued by users of a radiology image search engine. Results Estimated precision was 0.897 (95% confidence interval, 0.857–0.937). Estimated recall was 0.930 (95% confidence interval, 0.838–1.000). In 5,535 of 10,000 search queries (55%), concept-based retrieval found results not identified by simple keyword matching; in 2,086 searches (21%), more than 75% of the results were found by concept-based search alone. Conclusion Concept-based indexing of radiology journal figure captions achieved very high precision and recall, and significantly improved image retrieval. PMID:19261938

  19. 40 CFR 63.4081 - Am I subject to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., and electric heat pumps. Specifically excluded are heat transfer coils and large commercial and... high as the rates specified in paragraph (a) of this section. (3) The surface coating of heat transfer...) or by automated means (e.g., transfer through pipes using pumps); and (9) Handling and conveying of...

  20. Multicenter Comparative Evaluation of Five Commercial Methods for Toxoplasma DNA Extraction from Amniotic Fluid▿

    PubMed Central

    Yera, H.; Filisetti, D.; Bastien, P.; Ancelle, T.; Thulliez, P.; Delhaes, L.

    2009-01-01

    Over the past few years, a number of new nucleic acid extraction methods and extraction platforms using chemistry combined with magnetic or silica particles have been developed, in combination with instruments to facilitate the extraction procedure. The objective of the present study was to investigate the suitability of these automated methods for the isolation of Toxoplasma gondii DNA from amniotic fluid (AF). Therefore, three automated procedures were compared to two commercialized manual extraction methods. The MagNA Pure Compact (Roche), BioRobot EZ1 (Qiagen), and easyMAG (bioMérieux) automated procedures were compared to two manual DNA extraction kits, the QIAamp DNA minikit (Qiagen) and the High Pure PCR template preparation kit (Roche). Evaluation was carried out with two specific Toxoplasma PCRs (targeting the 529-bp repeat element), inhibitor search PCRs, and human beta-globin PCRs. The samples each consisted of 4 ml of AF with or without a calibrated Toxoplasma gondii RH strain suspension (0, 1, 2.5, 5, and 25 tachyzoites/ml). All PCR assays were laboratory-developed real-time PCR assays, using either TaqMan or fluorescent resonance energy transfer probes. A total of 1,178 PCRs were performed, including 978 Toxoplasma PCRs. The automated and manual methods were similar in sensitivity for DNA extraction from T. gondii at the highest concentration (25 Toxoplasma gondii cells/ml). However, our results showed that the DNA extraction procedures led to variable efficacy in isolating low concentrations of tachyzoites in AF samples (<5 Toxoplasma gondii cells/ml), a difference that might have repercussions since low parasite concentrations in AF exist and can lead to congenital toxoplasmosis. PMID:19846633

  1. Toward standardized quantitative image quality (IQ) assessment in computed tomography (CT): A comprehensive framework for automated and comparative IQ analysis based on ICRU Report 87.

    PubMed

    Pahn, Gregor; Skornitzke, Stephan; Schlemmer, Hans-Peter; Kauczor, Hans-Ulrich; Stiller, Wolfram

    2016-01-01

    Based on the guidelines from "Report 87: Radiation Dose and Image-quality Assessment in Computed Tomography" of the International Commission on Radiation Units and Measurements (ICRU), a software framework for automated quantitative image quality analysis was developed and its usability for a variety of scientific questions demonstrated. The extendable framework currently implements the calculation of the recommended Fourier image quality (IQ) metrics modulation transfer function (MTF) and noise-power spectrum (NPS), and additional IQ quantities such as noise magnitude, CT number accuracy, uniformity across the field-of-view, contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of simulated lesions for a commercially available cone-beam phantom. Sample image data were acquired with different scan and reconstruction settings on CT systems from different manufacturers. Spatial resolution is analyzed in terms of edge-spread function, line-spread-function, and MTF. 3D NPS is calculated according to ICRU Report 87, and condensed to 2D and radially averaged 1D representations. Noise magnitude, CT numbers, and uniformity of these quantities are assessed on large samples of ROIs. Low-contrast resolution (CNR, SNR) is quantitatively evaluated as a function of lesion contrast and diameter. Simultaneous automated processing of several image datasets allows for straightforward comparative assessment. The presented framework enables systematic, reproducible, automated and time-efficient quantitative IQ analysis. Consistent application of the ICRU guidelines facilitates standardization of quantitative assessment not only for routine quality assurance, but for a number of research questions, e.g. the comparison of different scanner models or acquisition protocols, and the evaluation of new technology or reconstruction methods. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  2. Managing protected health information in distributed research network environments: automated review to facilitate collaboration

    PubMed Central

    2013-01-01

    Background Multi-site health sciences research is becoming more common, as it enables investigation of rare outcomes and diseases and new healthcare innovations. Multi-site research usually involves the transfer of large amounts of research data between collaborators, which increases the potential for accidental disclosures of protected health information (PHI). Standard protocols for preventing release of PHI are extremely vulnerable to human error, particularly when the shared data sets are large. Methods To address this problem, we developed an automated program (SAS macro) to identify possible PHI in research data before it is transferred between research sites. The macro reviews all data in a designated directory to identify suspicious variable names and data patterns. The macro looks for variables that may contain personal identifiers such as medical record numbers and social security numbers. In addition, the macro identifies dates and numbers that may identify people who belong to small groups, who may be identifiable even in the absences of traditional identifiers. Results Evaluation of the macro on 100 sample research data sets indicated a recall of 0.98 and precision of 0.81. Conclusions When implemented consistently, the macro has the potential to streamline the PHI review process and significantly reduce accidental PHI disclosures. PMID:23521861

  3. Collecting and Animating Online Satellite Images.

    ERIC Educational Resources Information Center

    Irons, Ralph

    1995-01-01

    Describes how to generate automated classroom resources from the Internet. Topics covered include viewing animated satellite weather images using file transfer protocol (FTP); sources of images on the Internet; shareware available for viewing images; software for automating image retrieval; procedures for animating satellite images; and storing…

  4. A simple hand‐held magnet array for efficient and reproducible SABRE hyperpolarisation using manual sample shaking

    PubMed Central

    Richardson, Peter M.; Jackson, Scott; Parrott, Andrew J.; Nordon, Alison; Duckett, Simon B.

    2018-01-01

    Signal amplification by reversible exchange (SABRE) is a hyperpolarisation technique that catalytically transfers nuclear polarisation from parahydrogen, the singlet nuclear isomer of H2, to a substrate in solution. The SABRE exchange reaction is carried out in a polarisation transfer field (PTF) of tens of gauss before transfer to a stronger magnetic field for nuclear magnetic resonance (NMR) detection. In the simplest implementation, polarisation transfer is achieved by shaking the sample in the stray field of a superconducting NMR magnet. Although convenient, this method suffers from limited reproducibility and cannot be used with NMR spectrometers that do not have appreciable stray fields, such as benchtop instruments. Here, we use a simple hand‐held permanent magnet array to provide the necessary PTF during sample shaking. We find that the use of this array provides a 25% increase in SABRE enhancement over the stray field approach, while also providing improved reproducibility. Arrays with a range of PTFs were tested, and the PTF‐dependent SABRE enhancements were found to be in excellent agreement with comparable experiments carried out using an automated flow system where an electromagnet is used to generate the PTF. We anticipate that this approach will improve the efficiency and reproducibility of SABRE experiments carried out using manual shaking and will be particularly useful for benchtop NMR, where a suitable stray field is not readily accessible. The ability to construct arrays with a range of PTFs will also enable the rapid optimisation of SABRE enhancement as function of PTF for new substrate and catalyst systems. PMID:29193324

  5. Advancing automation and robotics technology for the Space Station and for the US economy, volume 2

    NASA Technical Reports Server (NTRS)

    1985-01-01

    In response to Public Law 98-371, dated July 18, 1984, the NASA Advanced Technology Advisory Committee has studied automation and robotics for use in the Space Station. The Technical Report, Volume 2, provides background information on automation and robotics technologies and their potential and documents: the relevant aspects of Space Station design; representative examples of automation and robotics; applications; the state of the technology and advances needed; and considerations for technology transfer to U.S. industry and for space commercialization.

  6. SHARP: Spacecraft Health Automated Reasoning Prototype

    NASA Technical Reports Server (NTRS)

    Atkinson, David J.

    1991-01-01

    The planetary spacecraft mission OPS as applied to SHARP is studied. Knowledge systems involved in this study are detailed. SHARP development task and Voyager telecom link analysis were examined. It was concluded that artificial intelligence has a proven capability to deliver useful functions in a real time space flight operations environment. SHARP has precipitated major change in acceptance of automation at JPL. The potential payoff from automation using AI is substantial. SHARP, and other AI technology is being transferred into systems in development including mission operations automation, science data systems, and infrastructure applications.

  7. An Integrated Tool for System Analysis of Sample Return Vehicles

    NASA Technical Reports Server (NTRS)

    Samareh, Jamshid A.; Maddock, Robert W.; Winski, Richard G.

    2012-01-01

    The next important step in space exploration is the return of sample materials from extraterrestrial locations to Earth for analysis. Most mission concepts that return sample material to Earth share one common element: an Earth entry vehicle. The analysis and design of entry vehicles is multidisciplinary in nature, requiring the application of mass sizing, flight mechanics, aerodynamics, aerothermodynamics, thermal analysis, structural analysis, and impact analysis tools. Integration of a multidisciplinary problem is a challenging task; the execution process and data transfer among disciplines should be automated and consistent. This paper describes an integrated analysis tool for the design and sizing of an Earth entry vehicle. The current tool includes the following disciplines: mass sizing, flight mechanics, aerodynamics, aerothermodynamics, and impact analysis tools. Python and Java languages are used for integration. Results are presented and compared with the results from previous studies.

  8. Helios: History and Anatomy of a Successful In-House Enterprise High-Throughput Screening and Profiling Data Analysis System.

    PubMed

    Gubler, Hanspeter; Clare, Nicholas; Galafassi, Laurent; Geissler, Uwe; Girod, Michel; Herr, Guy

    2018-06-01

    We describe the main characteristics of the Novartis Helios data analysis software system (Novartis, Basel, Switzerland) for plate-based screening and profiling assays, which was designed and built about 11 years ago. It has been in productive use for more than 10 years and is one of the important standard software applications running for a large user community at all Novartis Institutes for BioMedical Research sites globally. A high degree of automation is reached by embedding the data analysis capabilities into a software ecosystem that deals with the management of samples, plates, and result data files, including automated data loading. The application provides a series of analytical procedures, ranging from very simple to advanced, which can easily be assembled by users in very flexible ways. This also includes the automatic derivation of a large set of quality control (QC) characteristics at every step. Any of the raw, intermediate, and final results and QC-relevant quantities can be easily explored through linked visualizations. Links to global assay metadata management, data warehouses, and an electronic lab notebook system are in place. Automated transfer of relevant data to data warehouses and electronic lab notebook systems are also implemented.

  9. Transferring x-ray based automated threat detection between scanners with different energies and resolution

    NASA Astrophysics Data System (ADS)

    Caldwell, M.; Ransley, M.; Rogers, T. W.; Griffin, L. D.

    2017-10-01

    A significant obstacle to developing high performance Deep Learning algorithms for Automated Threat Detection (ATD) in security X-ray imagery, is the difficulty of obtaining large training datasets. In our previous work, we circumvented this problem for ATD in cargo containers, using Threat Image Projection and data augmentation. In this work, we investigate whether data scarcity for other modalities, such as parcels and baggage, can be ameliorated by transforming data from one domain so that it approximates the appearance of another. We present an ontology of ATD datasets to assess where transfer learning may be applied. We define frameworks for transfer at the training and testing stages, and compare the results for both methods against ATD where a common data source is used for training and testing. Our results show very poor transfer, which we attribute to the difficulty of accurately matching the blur and contrast characteristics of different scanners.

  10. ROBOCAL: Gamma-ray isotopic hardware/software interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hurd, J.R.; Bonner, C.A.; Ostenak, C.A.

    1989-01-01

    ROBOCAL, presently being developed at the Los Alamos National Laboratory, is a full-scale prototypical robotic system for remotely performing calorimetric and gamma-ray isotopics measurements of nuclear materials. It features a fully automated vertical stacker-retriever for storing and retrieving packaged nuclear materials from a multi-drawer system, and a fully automated, uniquely integrated gantry robot for programmable selection and transfer of nuclear materials to calorimetric and gamma-ray isotopic measurement stations. Since ROBOCAL is to require almost no operator intervention, a mechanical control system is required in addition to a totally automated assay system. The assay system must be a completely integrated datamore » acquisition and isotopic analysis package fully capable of performing state-of-the-art homogeneous and heterogeneous analyses on many varied matrices. The TRIFID assay system being discussed at this conference by J. G. Fleissner of the Rocky Flats Plant has been adopted because of its many automated features. These include: MCA/ADC setup and acquisition; spectral storage and analysis utilizing an expert system formalism; report generation with internal measurement control printout; user friendly screens and menus. The mechanical control portion consists primarily of two detector platforms and a sample platform, each with independent movement. Some minor modifications and additions are needed with TRIFID to interface the assay and mechanical portions with the CimRoc 4000 software controlling the robot. 6 refs., 5 figs., 3 tabs.« less

  11. Orbital transfer vehicle launch operations study: Automated technology knowledge base, volume 4

    NASA Technical Reports Server (NTRS)

    1986-01-01

    A simplified retrieval strategy for compiling automation-related bibliographies from NASA/RECON is presented. Two subsets of NASA Thesaurus subject terms were extracted: a primary list, which is used to obtain an initial set of citations; and a secondary list, which is used to limit or further specify a large initial set of citations. These subject term lists are presented in Appendix A as the Automated Technology Knowledge Base (ATKB) Thesaurus.

  12. Advantages and challenges in automated apatite fission track counting

    NASA Astrophysics Data System (ADS)

    Enkelmann, E.; Ehlers, T. A.

    2012-04-01

    Fission track thermochronometer data are often a core element of modern tectonic and denudation studies. Soon after the development of the fission track methods interest emerged for the developed an automated counting procedure to replace the time consuming labor of counting fission tracks under the microscope. Automated track counting became feasible in recent years with increasing improvements in computer software and hardware. One such example used in this study is the commercial automated fission track counting procedure from Autoscan Systems Pty that has been highlighted through several venues. We conducted experiments that are designed to reliably and consistently test the ability of this fully automated counting system to recognize fission tracks in apatite and a muscovite external detector. Fission tracks were analyzed in samples with a step-wise increase in sample complexity. The first set of experiments used a large (mm-size) slice of Durango apatite cut parallel to the prism plane. Second, samples with 80-200 μm large apatite grains of Fish Canyon Tuff were analyzed. This second sample set is characterized by complexities often found in apatites in different rock types. In addition to the automated counting procedure, the same samples were also analyzed using conventional counting procedures. We found for all samples that the fully automated fission track counting procedure using the Autoscan System yields a larger scatter in the fission track densities measured compared to conventional (manual) track counting. This scatter typically resulted from the false identification of tracks due surface and mineralogical defects, regardless of the image filtering procedure used. Large differences between track densities analyzed with the automated counting persisted between different grains analyzed in one sample as well as between different samples. As a result of these differences a manual correction of the fully automated fission track counts is necessary for each individual surface area and grain counted. This manual correction procedure significantly increases (up to four times) the time required to analyze a sample with the automated counting procedure compared to the conventional approach.

  13. Simple System for Isothermal DNA Amplification Coupled to Lateral Flow Detection

    PubMed Central

    Roskos, Kristina; Hickerson, Anna I.; Lu, Hsiang-Wei; Ferguson, Tanya M.; Shinde, Deepali N.; Klaue, Yvonne; Niemz, Angelika

    2013-01-01

    Infectious disease diagnosis in point-of-care settings can be greatly improved through integrated, automated nucleic acid testing devices. We have developed an early prototype for a low-cost system which executes isothermal DNA amplification coupled to nucleic acid lateral flow (NALF) detection in a mesofluidic cartridge attached to a portable instrument. Fluid handling inside the cartridge is facilitated through one-way passive valves, flexible pouches, and electrolysis-driven pumps, which promotes a compact and inexpensive instrument design. The closed-system disposable prevents workspace amplicon contamination. The cartridge design is based on standard scalable manufacturing techniques such as injection molding. Nucleic acid amplification occurs in a two-layer pouch that enables efficient heat transfer. We have demonstrated as proof of principle the amplification and detection of Mycobacterium tuberculosis (M.tb) genomic DNA in the cartridge, using either Loop Mediated Amplification (LAMP) or the Exponential Amplification Reaction (EXPAR), both coupled to NALF detection. We envision that a refined version of this cartridge, including upstream sample preparation coupled to amplification and detection, will enable fully-automated sample-in to answer-out infectious disease diagnosis in primary care settings of low-resource countries with high disease burden. PMID:23922706

  14. Pulse-Flow Microencapsulation System

    NASA Technical Reports Server (NTRS)

    Morrison, Dennis R.

    2006-01-01

    The pulse-flow microencapsulation system (PFMS) is an automated system that continuously produces a stream of liquid-filled microcapsules for delivery of therapeutic agents to target tissues. Prior microencapsulation systems have relied on batch processes that involve transfer of batches between different apparatuses for different stages of production followed by sampling for acquisition of quality-control data, including measurements of size. In contrast, the PFMS is a single, microprocessor-controlled system that performs all processing steps, including acquisition of quality-control data. The quality-control data can be used as real-time feedback to ensure the production of large quantities of uniform microcapsules.

  15. Small Libraries Online: Automating Circulation and Public Access Catalogs. Participant Workbook.

    ERIC Educational Resources Information Center

    Garcia, C. Rebecca; Bridge, Frank R.

    This workbook, meant to be used in a workshop, presents information on and guidelines for automating small libraries: (1) planning for automation; (2) automated system procurement and evaluation; (3) data conversion issues; (4) sample configuration worksheets; (5) sample configuration costs; (6) site preparation; (7) training; and (8) acceptance…

  16. Automation; The New Industrial Revolution.

    ERIC Educational Resources Information Center

    Arnstein, George E.

    Automation is a word that describes the workings of computers and the innovations of automatic transfer machines in the factory. As the hallmark of the new industrial revolution, computers displace workers and create a need for new skills and retraining programs. With improved communication between industry and the educational community to…

  17. 30 CFR 227.600 - What automated verification functions may a State perform?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... involves systematic monitoring of production and royalty reports to identify and resolve reporting or... reported by royalty reporters to sales and transfer volumes reported by production reporters. If you request delegation of automated comparison of sales and production volumes, you must perform at least the...

  18. 77 FR 49048 - Self-Regulatory Organizations; The Depository Trust Company; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-15

    ... to certain issues of securities in DTC's Fast Automated Securities Transfer program (``FAST''). For securities that are part of the FAST program, the transfer agents hold the securities registered in the name...

  19. An automation-assisted generic approach for biological sample preparation and LC-MS/MS method validation.

    PubMed

    Zhang, Jie; Wei, Shimin; Ayres, David W; Smith, Harold T; Tse, Francis L S

    2011-09-01

    Although it is well known that automation can provide significant improvement in the efficiency of biological sample preparation in quantitative LC-MS/MS analysis, it has not been widely implemented in bioanalytical laboratories throughout the industry. This can be attributed to the lack of a sound strategy and practical procedures in working with robotic liquid-handling systems. Several comprehensive automation assisted procedures for biological sample preparation and method validation were developed and qualified using two types of Hamilton Microlab liquid-handling robots. The procedures developed were generic, user-friendly and covered the majority of steps involved in routine sample preparation and method validation. Generic automation procedures were established as a practical approach to widely implement automation into the routine bioanalysis of samples in support of drug-development programs.

  20. Automated sample exchange and tracking system for neutron research at cryogenic temperatures

    NASA Astrophysics Data System (ADS)

    Rix, J. E.; Weber, J. K. R.; Santodonato, L. J.; Hill, B.; Walker, L. M.; McPherson, R.; Wenzel, J.; Hammons, S. E.; Hodges, J.; Rennich, M.; Volin, K. J.

    2007-01-01

    An automated system for sample exchange and tracking in a cryogenic environment and under remote computer control was developed. Up to 24 sample "cans" per cycle can be inserted and retrieved in a programed sequence. A video camera acquires a unique identification marked on the sample can to provide a record of the sequence. All operations are coordinated via a LABVIEW™ program that can be operated locally or over a network. The samples are contained in vanadium cans of 6-10mm in diameter and equipped with a hermetically sealed lid that interfaces with the sample handler. The system uses a closed-cycle refrigerator (CCR) for cooling. The sample was delivered to a precooling location that was at a temperature of ˜25K, after several minutes, it was moved onto a "landing pad" at ˜10K that locates the sample in the probe beam. After the sample was released onto the landing pad, the sample handler was retracted. Reading the sample identification and the exchange operation takes approximately 2min. The time to cool the sample from ambient temperature to ˜10K was approximately 7min including precooling time. The cooling time increases to approximately 12min if precooling is not used. Small differences in cooling rate were observed between sample materials and for different sample can sizes. Filling the sample well and the sample can with low pressure helium is essential to provide heat transfer and to achieve useful cooling rates. A resistive heating coil can be used to offset the refrigeration so that temperatures up to ˜350K can be accessed and controlled using a proportional-integral-derivative control loop. The time for the landing pad to cool to ˜10K after it has been heated to ˜240K was approximately 20min.

  1. Automated Fabrication Technologies for High Performance Polymer Composites

    NASA Technical Reports Server (NTRS)

    Shuart , M. J.; Johnston, N. J.; Dexter, H. B.; Marchello, J. M.; Grenoble, R. W.

    1998-01-01

    New fabrication technologies are being exploited for building high graphite-fiber-reinforced composite structure. Stitched fiber preforms and resin film infusion have been successfully demonstrated for large, composite wing structures. Other automatic processes being developed include automated placement of tacky, drapable epoxy towpreg, automated heated head placement of consolidated ribbon/tape, and vacuum-assisted resin transfer molding. These methods have the potential to yield low cost high performance structures by fabricating composite structures to net shape out-of-autoclave.

  2. 12 CFR 205.16 - Disclosures at automated teller machines.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... which a consumer initiates an electronic fund transfer or a balance inquiry and that does not hold the account to or from which the transfer is made, or about which an inquiry is made. (b) General. An... transfer or a balance inquiry shall: (1) Provide notice that a fee will be imposed for providing electronic...

  3. Automation Hooks Architecture for Flexible Test Orchestration - Concept Development and Validation

    NASA Technical Reports Server (NTRS)

    Lansdowne, C. A.; Maclean, John R.; Winton, Chris; McCartney, Pat

    2011-01-01

    The Automation Hooks Architecture Trade Study for Flexible Test Orchestration sought a standardized data-driven alternative to conventional automated test programming interfaces. The study recommended composing the interface using multicast DNS (mDNS/SD) service discovery, Representational State Transfer (Restful) Web Services, and Automatic Test Markup Language (ATML). We describe additional efforts to rapidly mature the Automation Hooks Architecture candidate interface definition by validating it in a broad spectrum of applications. These activities have allowed us to further refine our concepts and provide observations directed toward objectives of economy, scalability, versatility, performance, severability, maintainability, scriptability and others.

  4. Comparison Between Conventional and Automated Techniques for Blood Grouping and Crossmatching: Experience from a Tertiary Care Centre.

    PubMed

    Bhagwat, Swarupa Nikhil; Sharma, Jayashree H; Jose, Julie; Modi, Charusmita J

    2015-01-01

    The routine immunohematological tests can be performed by automated as well as manual techniques. These techniques have advantages and disadvantages inherent to them. The present study aims to compare the results of manual and automated techniques for blood grouping and crossmatching so as to validate the automated system effectively. A total of 1000 samples were subjected to blood grouping by the conventional tube technique (CTT) and the automated microplate LYRA system on Techno TwinStation. A total of 269 samples (multitransfused patients and multigravida females) were compared for 927 crossmatches by the CTT in indirect antiglobulin phase against the column agglutination technique (CAT) performed on Techno TwinStation. For blood grouping, the study showed a concordance in results for 942/1000 samples (94.2%), discordance for 4/1000 (0.4%) samples and uninterpretable result for 54/1000 samples (5.4%). On resolution, the uninterpretable results reduced to 49/1000 samples (4.9%) with 951/1000 samples (95.1%) showing concordant results. For crossmatching, the automated CAT showed concordant results in 887/927 (95.6%) and discordant results in 3/927 (0.32%) crossmatches as compared to the CTT. Total 37/927 (3.9%) crossmatches were not interpretable by the automated technique. The automated system shows a high concordance of results with CTT and hence can be brought into routine use. However, the high proportion of uninterpretable results emphasizes on the fact that proper training and standardization are needed prior to its use.

  5. ATV ops

    NASA Image and Video Library

    2013-06-18

    ISS036-E-009184 (18 June 2013) --- Russian cosmonaut Pavel Vinogradov, Expedition 36 commander, opens the hatch in the Zvezda Service Module transfer tunnel/ATV vestibule of the International Space Station after European Space Agency's Automated Transfer Vehicle-4 (ATV-4) "Albert Einstein" docked with the station.

  6. Automated determination of the stable carbon isotopic composition (δ13C) of total dissolved inorganic carbon (DIC) and total nonpurgeable dissolved organic carbon (DOC) in aqueous samples: RSIL lab codes 1851 and 1852

    USGS Publications Warehouse

    Révész, Kinga M.; Doctor, Daniel H.

    2014-01-01

    The purposes of the Reston Stable Isotope Laboratory (RSIL) lab codes 1851 and 1852 are to determine the total carbon mass and the ratio of the stable isotopes of carbon (δ13C) for total dissolved inorganic carbon (DIC, lab code 1851) and total nonpurgeable dissolved organic carbon (DOC, lab code 1852) in aqueous samples. The analysis procedure is automated according to a method that utilizes a total carbon analyzer as a peripheral sample preparation device for analysis of carbon dioxide (CO2) gas by a continuous-flow isotope ratio mass spectrometer (CF-IRMS). The carbon analyzer produces CO2 and determines the carbon mass in parts per million (ppm) of DIC and DOC in each sample separately, and the CF-IRMS determines the carbon isotope ratio of the produced CO2. This configuration provides a fully automated analysis of total carbon mass and δ13C with no operator intervention, additional sample preparation, or other manual analysis. To determine the DIC, the carbon analyzer transfers a specified sample volume to a heated (70 °C) reaction vessel with a preprogrammed volume of 10% phosphoric acid (H3PO4), which allows the carbonate and bicarbonate species in the sample to dissociate to CO2. The CO2 from the reacted sample is subsequently purged with a flow of helium gas that sweeps the CO2 through an infrared CO2 detector and quantifies the CO2. The CO2 is then carried through a high-temperature (650 °C) scrubber reactor, a series of water traps, and ultimately to the inlet of the mass spectrometer. For the analysis of total dissolved organic carbon, the carbon analyzer performs a second step on the sample in the heated reaction vessel during which a preprogrammed volume of sodium persulfate (Na2S2O8) is added, and the hydroxyl radicals oxidize the organics to CO2. Samples containing 2 ppm to 30,000 ppm of carbon are analyzed. The precision of the carbon isotope analysis is within 0.3 per mill for DIC, and within 0.5 per mill for DOC.

  7. A generic template for automated bioanalytical ligand-binding assays using modular robotic scripts in support of discovery biotherapeutic programs.

    PubMed

    Duo, Jia; Dong, Huijin; DeSilva, Binodh; Zhang, Yan J

    2013-07-01

    Sample dilution and reagent pipetting are time-consuming steps in ligand-binding assays (LBAs). Traditional automation-assisted LBAs use assay-specific scripts that require labor-intensive script writing and user training. Five major script modules were developed on Tecan Freedom EVO liquid handling software to facilitate the automated sample preparation and LBA procedure: sample dilution, sample minimum required dilution, standard/QC minimum required dilution, standard/QC/sample addition, and reagent addition. The modular design of automation scripts allowed the users to assemble an automated assay with minimal script modification. The application of the template was demonstrated in three LBAs to support discovery biotherapeutic programs. The results demonstrated that the modular scripts provided the flexibility in adapting to various LBA formats and the significant time saving in script writing and scientist training. Data generated by the automated process were comparable to those by manual process while the bioanalytical productivity was significantly improved using the modular robotic scripts.

  8. Automation--down to the nuts and bolts.

    PubMed

    Fix, R J; Rowe, J M; McConnell, B C

    2000-01-01

    Laboratories that once viewed automation as an expensive luxury are now looking to automation as a solution to increase sample throughput, to help ensure data integrity and to improve laboratory safety. The question is no longer, 'Should we automate?', but 'How should we approach automation?' A laboratory may choose from three approaches when deciding to automate: (1) contract with a third party vendor to produce a turnkey system, (2) develop and fabricate the system in-house or (3) some combination of approaches (1) and (2). The best approach for a given laboratory depends upon its available resources. The first lesson to be learned in automation is that no matter how straightforward an idea appears in the beginning, the solution will not be realized until many complex problems have been resolved. Issues dealing with sample vessel manipulation, liquid handling and system control must be addressed before a final design can be developed. This requires expertise in engineering, electronics, programming and chemistry. Therefore, the team concept of automation should be employed to help ensure success. This presentation discusses the advantages and disadvantages of the three approaches to automation. The development of an automated sample handling and control system for the STAR System focused microwave will be used to illustrate the complexities encountered in a seemingly simple project, and to highlight the importance of the team concept to automation no matter which approach is taken. The STAR System focused microwave from CEM Corporation is an open vessel digestion system with six microwave cells. This system is used to prepare samples for trace metal determination. The automated sample handling was developed around a XYZ motorized gantry system. Grippers were specially designed to perform several different functions and to provide feedback to the control software. Software was written in Visual Basic 5.0 to control the movement of the samples and the operation and monitoring of the STAR microwave. This software also provides a continuous update of the system's status to the computer screen. The system provides unattended preparation of up to 59 samples per run.

  9. Human performance in a multiple-task environment: effects of automation reliability on visual attention allocation.

    PubMed

    Cullen, Ralph H; Rogers, Wendy A; Fisk, Arthur D

    2013-11-01

    Diagnostic automation has been posited to alleviate the high demands of multiple-task environments; however, mixed effects have been found pertaining to performance aid success. To better understand these effects, attention allocation must be studied directly. We developed a multiple-task environment to study the effects of automation on visual attention. Participants interacted with a system providing varying levels of automation and automation reliability and then were transferred to a system with no support. Attention allocation was measured by tracking the number of times each task was viewed. We found that participants receiving automation allocated their time according to the task frequency and that tasks that benefited most from automation were most harmed when it was removed. The results suggest that the degree to which automation affects multiple-task performance is dependent on the relative attributes of the tasks involved. Moreover, there is an inverse relationship between support and cost when automation fails. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  10. Automated DBS microsampling, microscale automation and microflow LC-MS for therapeutic protein PK.

    PubMed

    Zhang, Qian; Tomazela, Daniela; Vasicek, Lisa A; Spellman, Daniel S; Beaumont, Maribel; Shyong, BaoJen; Kenny, Jacqueline; Fauty, Scott; Fillgrove, Kerry; Harrelson, Jane; Bateman, Kevin P

    2016-04-01

    Reduce animal usage for discovery-stage PK studies for biologics programs using microsampling-based approaches and microscale LC-MS. We report the development of an automated DBS-based serial microsampling approach for studying the PK of therapeutic proteins in mice. Automated sample preparation and microflow LC-MS were used to enable assay miniaturization and improve overall assay throughput. Serial sampling of mice was possible over the full 21-day study period with the first six time points over 24 h being collected using automated DBS sample collection. Overall, this approach demonstrated comparable data to a previous study using single mice per time point liquid samples while reducing animal and compound requirements by 14-fold. Reduction in animals and drug material is enabled by the use of automated serial DBS microsampling for mice studies in discovery-stage studies of protein therapeutics.

  11. A simple hand-held magnet array for efficient and reproducible SABRE hyperpolarisation using manual sample shaking.

    PubMed

    Richardson, Peter M; Jackson, Scott; Parrott, Andrew J; Nordon, Alison; Duckett, Simon B; Halse, Meghan E

    2018-07-01

    Signal amplification by reversible exchange (SABRE) is a hyperpolarisation technique that catalytically transfers nuclear polarisation from parahydrogen, the singlet nuclear isomer of H 2 , to a substrate in solution. The SABRE exchange reaction is carried out in a polarisation transfer field (PTF) of tens of gauss before transfer to a stronger magnetic field for nuclear magnetic resonance (NMR) detection. In the simplest implementation, polarisation transfer is achieved by shaking the sample in the stray field of a superconducting NMR magnet. Although convenient, this method suffers from limited reproducibility and cannot be used with NMR spectrometers that do not have appreciable stray fields, such as benchtop instruments. Here, we use a simple hand-held permanent magnet array to provide the necessary PTF during sample shaking. We find that the use of this array provides a 25% increase in SABRE enhancement over the stray field approach, while also providing improved reproducibility. Arrays with a range of PTFs were tested, and the PTF-dependent SABRE enhancements were found to be in excellent agreement with comparable experiments carried out using an automated flow system where an electromagnet is used to generate the PTF. We anticipate that this approach will improve the efficiency and reproducibility of SABRE experiments carried out using manual shaking and will be particularly useful for benchtop NMR, where a suitable stray field is not readily accessible. The ability to construct arrays with a range of PTFs will also enable the rapid optimisation of SABRE enhancement as function of PTF for new substrate and catalyst systems. © 2017 The Authors Magnetic Resonance in Chemistry Published by John Wiley & Sons Ltd.

  12. Performance characteristics of an automated gas chromatograph-ion trap mass spectrometer system used for the 1995 Southern Oxidants Study field investigation in Nashville, Tennessee

    NASA Astrophysics Data System (ADS)

    Daughtrey, E. Hunter; Adams, Jeffrey R.; Oliver, Karen D.; Kronmiller, Keith G.; McClenny, William A.

    1998-09-01

    A trailer-deployed automated gas chromatograph-mass spectrometer (autoGC-MS) system capable of making continuous hourly measurements was used to determine volatile organic compounds (VOCs) in ambient air at New Hendersonville, Tennessee, and Research Triangle Park, North Carolina, in 1995. The system configuration, including the autoGC-MS, trailer and transfer line, siting, and sampling plan and schedule, is described. The autoGC-MS system employs a pair of matched sorbent traps to allow simultaneous sampling and desorption. Desorption is followed by Stirling engine cryofocusing and subsequent GC separation and mass spectral identification and quantification. Quality control measurements described include evaluating precision and accuracy of replicate analyses of independently supplied audit and round-robin canisters and determining the completeness of the data sets taken in Tennessee. Data quality objectives for precision (±10%) and accuracy (±20%) of 10- to 20-ppbv audit canisters and a completeness of >75% data capture were met. Quality assurance measures used in reviewing the data set include retention time stability, calibration checks, frequency distribution checks, and checks of the mass spectra. Special procedures and tests were used to minimize sorbent trap artifacts, to verify the quality of a standard prepared in our laboratory, and to prove the integrity of the insulated, heated transfer line. A rigorous determination of total system blank concentration levels using humidified scientific air spiked with ozone allowed estimation of method detection limits, ranging from 0.01 to 1.0 ppb C, for most of the 100 target compounds, which were a composite list of the target compounds for the Photochemical Assessment Monitoring Station network, those for Environmental Protection Agency method TO-14, and selected oxygenated VOCs.

  13. The Architecture Design of Detection and Calibration System for High-voltage Electrical Equipment

    NASA Astrophysics Data System (ADS)

    Ma, Y.; Lin, Y.; Yang, Y.; Gu, Ch; Yang, F.; Zou, L. D.

    2018-01-01

    With the construction of Material Quality Inspection Center of Shandong electric power company, Electric Power Research Institute takes on more jobs on quality analysis and laboratory calibration for high-voltage electrical equipment, and informationization construction becomes urgent. In the paper we design a consolidated system, which implements the electronic management and online automation process for material sampling, test apparatus detection and field test. In the three jobs we use QR code scanning, online Word editing and electronic signature. These techniques simplify the complex process of warehouse management and testing report transferring, and largely reduce the manual procedure. The construction of the standardized detection information platform realizes the integrated management of high-voltage electrical equipment from their networking, running to periodic detection. According to system operation evaluation, the speed of transferring report is doubled, and querying data is also easier and faster.

  14. Spatially resolved proteome mapping of laser capture microdissected tissue with automated sample transfer to nanodroplets.

    PubMed

    Zhu, Ying; Dou, Maowei; Piehowski, Paul D; Liang, Yiran; Wang, Fangjun; Chu, Rosalie K; Chrisler, Will; Smith, Jordan N; Schwarz, Kaitlynn C; Shen, Yufeng; Shukla, Anil K; Moore, Ronald J; Smith, Richard D; Qian, Wei-Jun; Kelly, Ryan T

    2018-06-24

    Current mass spectrometry (MS)-based proteomics approaches are ineffective for mapping protein expression in tissue sections with high spatial resolution due to the limited overall sensitivity of conventional workflows. Here we report an integrated and automated method to advance spatially resolved proteomics by seamlessly coupling laser capture microdissection (LCM) with a recently developed nanoliter-scale sample preparation system termed nanoPOTS (Nanodroplet Processing in One pot for Trace Samples). The workflow is enabled by prepopulating nanowells with DMSO, which serves as a sacrificial capture liquid for microdissected tissues. The DMSO droplets efficiently collect laser-pressure catapulted LCM tissues as small as 20 µm in diameter with success rates >87%. We also demonstrate that tissue treatment with DMSO can significantly improve proteome coverage, likely due to its ability to dissolve lipids from tissue and enhance protein extraction efficiency. The LCM-nanoPOTS platform was able to identify 180, 695, and 1827 protein groups on average from 12-µm-thick rat brain cortex tissue sections with diameters of 50, 100, and 200 µm, respectively. We also analyzed 100-µm-diameter sections corresponding to 10-18 cells from three different regions of rat brain and comparatively quantified ~1000 proteins, demonstrating the potential utility for high-resolution spatially resolved mapping of protein expression in tissues. Published under license by The American Society for Biochemistry and Molecular Biology, Inc.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This paper reports on an automated metering/proving system for custody transfer of crude oil at the Phillips 66 Co. tanker unloading terminal in Freeport, Texas. It is described as one of the most sophisticated systems developed. The menu-driven, one-button automation removes the proving sequence entirely from manual control. The system also is the to be cost-effective and versatile compared to a dedicated flow computer with API calculation capabilities. Developed by Puffer-Sweiven, systems integrators, the new technology additionally is thought to be the first custody transfer system to employ a programmable logic controller (PLC). The PLC provides the automation, gathers andmore » stores all raw data, and prints alarms. Also the system uses a personal computer operator interface (OI) that runs on the Intel iRMX real time operating system. The OI is loaded with Puffer-Sweiven application software that performs API meter factor and volume correction calculations as well as present color graphics and generate reports.« less

  16. Performance of Copan WASP for Routine Urine Microbiology

    PubMed Central

    Quiblier, Chantal; Jetter, Marion; Rominski, Mark; Mouttet, Forouhar; Böttger, Erik C.; Keller, Peter M.

    2015-01-01

    This study compared a manual workup of urine clinical samples with fully automated WASPLab processing. As a first step, two different inocula (1 and 10 μl) and different streaking patterns were compared using WASP and InoqulA BT instrumentation. Significantly more single colonies were produced with the10-μl inoculum than with the 1-μl inoculum, and automated streaking yielded significantly more single colonies than manual streaking on whole plates (P < 0.001). In a second step, 379 clinical urine samples were evaluated using WASP and the manual workup. Average numbers of detected morphologies, recovered species, and CFUs per milliliter of all 379 urine samples showed excellent agreement between WASPLab and the manual workup. The percentage of urine samples clinically categorized as positive or negative did not differ between the automated and manual workflow, but within the positive samples, automated processing by WASPLab resulted in the detection of more potential pathogens. In summary, the present study demonstrates that (i) the streaking pattern, i.e., primarily the number of zigzags/length of streaking lines, is critical for optimizing the number of single colonies yielded from primary cultures of urine samples; (ii) automated streaking by the WASP instrument is superior to manual streaking regarding the number of single colonies yielded (for 32.2% of the samples); and (iii) automated streaking leads to higher numbers of detected morphologies (for 47.5% of the samples), species (for 17.4% of the samples), and pathogens (for 3.4% of the samples). The results of this study point to an improved quality of microbiological analyses and laboratory reports when using automated sample processing by WASP and WASPLab. PMID:26677255

  17. Early Program Development

    NASA Image and Video Library

    1989-01-01

    In June 1989 the Marshall Space Flight Center initiated studies of Space Transfer Vehicle (STV) concepts. A successor to the Orbital Transfer Vehicle (OTV) concept, the STV would be a high-performance space vehicle capable of transferring automated payloads from a Space Station to geosynchronous orbits, the Moon, or planets. Illustrated in this artist's concept are two STV's undergoing aerobraking maneuvers as they approach a Space Station.

  18. Selective automation and skill transfer in medical robotics: a demonstration on surgical knot-tying.

    PubMed

    Knoll, Alois; Mayer, Hermann; Staub, Christoph; Bauernschmitt, Robert

    2012-12-01

    Transferring non-trivial human manipulation skills to robot systems is a challenging task. There have been a number of attempts to design research systems for skill transfer, but the level of the complexity of the actual skills transferable to the robot was rather limited, and delicate operations requiring a high dexterity and long action sequences with many sub-operations were impossible to transfer. A novel approach to human-machine skill transfer for multi-arm robot systems is presented. The methodology capitalizes on the metaphor of 'scaffolded learning', which has gained widespread acceptance in psychology. The main idea is to formalize the superior knowledge of a teacher in a certain way to generate support for a trainee. In our case, the scaffolding is constituted by abstract patterns, which facilitate the structuring and segmentation of information during 'learning by demonstration'. The actual skill generalization is then based on simulating fluid dynamics. The approach has been successfully evaluated in the medical domain for the delicate task of automated knot-tying for suturing with standard surgical instruments and a realistic minimally invasive robotic surgery system. Copyright © 2012 John Wiley & Sons, Ltd.

  19. Comparison Between Conventional and Automated Techniques for Blood Grouping and Crossmatching: Experience from a Tertiary Care Centre

    PubMed Central

    Bhagwat, Swarupa Nikhil; Sharma, Jayashree H; Jose, Julie; Modi, Charusmita J

    2015-01-01

    Context: The routine immunohematological tests can be performed by automated as well as manual techniques. These techniques have advantages and disadvantages inherent to them. Aims: The present study aims to compare the results of manual and automated techniques for blood grouping and crossmatching so as to validate the automated system effectively. Materials and Methods: A total of 1000 samples were subjected to blood grouping by the conventional tube technique (CTT) and the automated microplate LYRA system on Techno TwinStation. A total of 269 samples (multitransfused patients and multigravida females) were compared for 927 crossmatches by the CTT in indirect antiglobulin phase against the column agglutination technique (CAT) performed on Techno TwinStation. Results: For blood grouping, the study showed a concordance in results for 942/1000 samples (94.2%), discordance for 4/1000 (0.4%) samples and uninterpretable result for 54/1000 samples (5.4%). On resolution, the uninterpretable results reduced to 49/1000 samples (4.9%) with 951/1000 samples (95.1%) showing concordant results. For crossmatching, the automated CAT showed concordant results in 887/927 (95.6%) and discordant results in 3/927 (0.32%) crossmatches as compared to the CTT. Total 37/927 (3.9%) crossmatches were not interpretable by the automated technique. Conclusions: The automated system shows a high concordance of results with CTT and hence can be brought into routine use. However, the high proportion of uninterpretable results emphasizes on the fact that proper training and standardization are needed prior to its use. PMID:26417159

  20. MARS: bringing the automation of small-molecule bioanalytical sample preparations to a new frontier.

    PubMed

    Li, Ming; Chou, Judy; Jing, Jing; Xu, Hui; Costa, Aldo; Caputo, Robin; Mikkilineni, Rajesh; Flannelly-King, Shane; Rohde, Ellen; Gan, Lawrence; Klunk, Lewis; Yang, Liyu

    2012-06-01

    In recent years, there has been a growing interest in automating small-molecule bioanalytical sample preparations specifically using the Hamilton MicroLab(®) STAR liquid-handling platform. In the most extensive work reported thus far, multiple small-molecule sample preparation assay types (protein precipitation extraction, SPE and liquid-liquid extraction) have been integrated into a suite that is composed of graphical user interfaces and Hamilton scripts. Using that suite, bioanalytical scientists have been able to automate various sample preparation methods to a great extent. However, there are still areas that could benefit from further automation, specifically, the full integration of analytical standard and QC sample preparation with study sample extraction in one continuous run, real-time 2D barcode scanning on the Hamilton deck and direct Laboratory Information Management System database connectivity. We developed a new small-molecule sample-preparation automation system that improves in all of the aforementioned areas. The improved system presented herein further streamlines the bioanalytical workflow, simplifies batch run design, reduces analyst intervention and eliminates sample-handling error.

  1. Flexible automated approach for quantitative liquid handling of complex biological samples.

    PubMed

    Palandra, Joe; Weller, David; Hudson, Gary; Li, Jeff; Osgood, Sarah; Hudson, Emily; Zhong, Min; Buchholz, Lisa; Cohen, Lucinda H

    2007-11-01

    A fully automated protein precipitation technique for biological sample preparation has been developed for the quantitation of drugs in various biological matrixes. All liquid handling during sample preparation was automated using a Hamilton MicroLab Star Robotic workstation, which included the preparation of standards and controls from a Watson laboratory information management system generated work list, shaking of 96-well plates, and vacuum application. Processing time is less than 30 s per sample or approximately 45 min per 96-well plate, which is then immediately ready for injection onto an LC-MS/MS system. An overview of the process workflow is discussed, including the software development. Validation data are also provided, including specific liquid class data as well as comparative data of automated vs manual preparation using both quality controls and actual sample data. The efficiencies gained from this automated approach are described.

  2. Technology transfer and evaluation for Space Station telerobotics

    NASA Technical Reports Server (NTRS)

    Price, Charles R.; Stokes, Lebarian; Diftler, Myron A.

    1994-01-01

    The international space station (SS) must take advantage of advanced telerobotics in order to maximize productivity and safety and to reduce maintenance costs. The Automation and Robotics Division at the NASA Lyndon B. Johnson Space Center (JSC) has designed, developed, and constructed the Automated Robotics Maintenance of Space Station (ARMSS) facility for the purpose of transferring and evaluating robotic technology that will reduce SS operation costs. Additionally, JSC had developed a process for expediting the transfer of technology from NASA research centers and evaluating these technologies in SS applications. Software and hardware system developed at the research centers and NASA sponsored universities are currently being transferred to JSC and integrated into the ARMSS for flight crew personnel testing. These technologies will be assessed relative to the SS baseline, and, after refinements, those technologies that provide significant performance improvements will be recommended as upgrades to the SS. Proximity sensors, vision algorithms, and manipulator controllers are among the systems scheduled for evaluation.

  3. Aviation Safety/Automation Program Conference

    NASA Technical Reports Server (NTRS)

    Morello, Samuel A. (Compiler)

    1990-01-01

    The Aviation Safety/Automation Program Conference - 1989 was sponsored by the NASA Langley Research Center on 11 to 12 October 1989. The conference, held at the Sheraton Beach Inn and Conference Center, Virginia Beach, Virginia, was chaired by Samuel A. Morello. The primary objective of the conference was to ensure effective communication and technology transfer by providing a forum for technical interchange of current operational problems and program results to date. The Aviation Safety/Automation Program has as its primary goal to improve the safety of the national airspace system through the development and integration of human-centered automation technologies for aircraft crews and air traffic controllers.

  4. Fully automated processing of fMRI data in SPM: from MRI scanner to PACS.

    PubMed

    Maldjian, Joseph A; Baer, Aaron H; Kraft, Robert A; Laurienti, Paul J; Burdette, Jonathan H

    2009-01-01

    Here we describe the Wake Forest University Pipeline, a fully automated method for the processing of fMRI data using SPM. The method includes fully automated data transfer and archiving from the point of acquisition, real-time batch script generation, distributed grid processing, interface to SPM in MATLAB, error recovery and data provenance, DICOM conversion and PACS insertion. It has been used for automated processing of fMRI experiments, as well as for the clinical implementation of fMRI and spin-tag perfusion imaging. The pipeline requires no manual intervention, and can be extended to any studies requiring offline processing.

  5. Laboratory automation of high-quality and efficient ligand-binding assays for biotherapeutic drug development.

    PubMed

    Wang, Jin; Patel, Vimal; Burns, Daniel; Laycock, John; Pandya, Kinnari; Tsoi, Jennifer; DeSilva, Binodh; Ma, Mark; Lee, Jean

    2013-07-01

    Regulated bioanalytical laboratories that run ligand-binding assays in support of biotherapeutics development face ever-increasing demand to support more projects with increased efficiency. Laboratory automation is a tool that has the potential to improve both quality and efficiency in a bioanalytical laboratory. The success of laboratory automation requires thoughtful evaluation of program needs and fit-for-purpose strategies, followed by pragmatic implementation plans and continuous user support. In this article, we present the development of fit-for-purpose automation of total walk-away and flexible modular modes. We shared the sustaining experience of vendor collaboration and team work to educate, promote and track the use of automation. The implementation of laboratory automation improves assay performance, data quality, process efficiency and method transfer to CRO in a regulated bioanalytical laboratory environment.

  6. Streamlined sign-out of capillary protein electrophoresis using middleware and an open-source macro application.

    PubMed

    Mathur, Gagan; Haugen, Thomas H; Davis, Scott L; Krasowski, Matthew D

    2014-01-01

    Interfacing of clinical laboratory instruments with the laboratory information system (LIS) via "middleware" software is increasingly common. Our clinical laboratory implemented capillary electrophoresis using a Sebia(®) Capillarys-2™ (Norcross, GA, USA) instrument for serum and urine protein electrophoresis. Using Data Innovations Instrument Manager, an interface was established with the LIS (Cerner) that allowed for bi-directional transmission of numeric data. However, the text of the interpretive pathology report was not properly transferred. To reduce manual effort and possibility for error in text data transfer, we developed scripts in AutoHotkey, a free, open-source macro-creation and automation software utility. Scripts were written to create macros that automated mouse and key strokes. The scripts retrieve the specimen accession number, capture user input text, and insert the text interpretation in the correct patient record in the desired format. The scripts accurately and precisely transfer narrative interpretation into the LIS. Combined with bar-code reading by the electrophoresis instrument, the scripts transfer data efficiently to the correct patient record. In addition, the AutoHotKey script automated repetitive key strokes required for manual entry into the LIS, making protein electrophoresis sign-out easier to learn and faster to use by the pathology residents. Scripts allow for either preliminary verification by residents or final sign-out by the attending pathologist. Using the open-source AutoHotKey software, we successfully improved the transfer of text data between capillary electrophoresis software and the LIS. The use of open-source software tools should not be overlooked as tools to improve interfacing of laboratory instruments.

  7. Automated two-dimensional interface for capillary gas chromatography

    DOEpatents

    Strunk, M.R.; Bechtold, W.E.

    1996-02-20

    A multidimensional gas chromatograph (GC) system is disclosed which has wide bore capillary and narrow bore capillary GC columns in series and has a novel system interface. Heart cuts from a high flow rate sample, separated by a wide bore GC column, are collected and directed to a narrow bore GC column with carrier gas injected at a lower flow compatible with a mass spectrometer. A bimodal six-way valve is connected with the wide bore GC column outlet and a bimodal four-way valve is connected with the narrow bore GC column inlet. A trapping and retaining circuit with a cold trap is connected with the six-way valve and a transfer circuit interconnects the two valves. The six-way valve is manipulated between first and second mode positions to collect analyte, and the four-way valve is manipulated between third and fourth mode positions to allow carrier gas to sweep analyte from a deactivated cold trap, through the transfer circuit, and then to the narrow bore GC capillary column for separation and subsequent analysis by a mass spectrometer. Rotary valves have substantially the same bore width as their associated columns to minimize flow irregularities and resulting sample peak deterioration. The rotary valves are heated separately from the GC columns to avoid temperature lag and resulting sample deterioration. 3 figs.

  8. Automated two-dimensional interface for capillary gas chromatography

    DOEpatents

    Strunk, Michael R.; Bechtold, William E.

    1996-02-20

    A multidimensional gas chromatograph (GC) system having wide bore capillary and narrow bore capillary GC columns in series and having a novel system interface. Heart cuts from a high flow rate sample, separated by a wide bore GC column, are collected and directed to a narrow bore GC column with carrier gas injected at a lower flow compatible with a mass spectrometer. A bimodal six-way valve is connected with the wide bore GC column outlet and a bimodal four-way valve is connected with the narrow bore GC column inlet. A trapping and retaining circuit with a cold trap is connected with the six-way valve and a transfer circuit interconnects the two valves. The six-way valve is manipulated between first and second mode positions to collect analyte, and the four-way valve is manipulated between third and fourth mode positions to allow carrier gas to sweep analyte from a deactivated cold trap, through the transfer circuit, and then to the narrow bore GC capillary column for separation and subsequent analysis by a mass spectrometer. Rotary valves have substantially the same bore width as their associated columns to minimize flow irregularities and resulting sample peak deterioration. The rotary valves are heated separately from the GC columns to avoid temperature lag and resulting sample deterioration.

  9. High-frequency, long-duration water sampling in acid mine drainage studies: a short review of current methods and recent advances in automated water samplers

    USGS Publications Warehouse

    Chapin, Thomas

    2015-01-01

    Hand-collected grab samples are the most common water sampling method but using grab sampling to monitor temporally variable aquatic processes such as diel metal cycling or episodic events is rarely feasible or cost-effective. Currently available automated samplers are a proven, widely used technology and typically collect up to 24 samples during a deployment. However, these automated samplers are not well suited for long-term sampling in remote areas or in freezing conditions. There is a critical need for low-cost, long-duration, high-frequency water sampling technology to improve our understanding of the geochemical response to temporally variable processes. This review article will examine recent developments in automated water sampler technology and utilize selected field data from acid mine drainage studies to illustrate the utility of high-frequency, long-duration water sampling.

  10. The Impact of Sampling Approach on Population Invariance in Automated Scoring of Essays. Research Report. ETS RR-13-18

    ERIC Educational Resources Information Center

    Zhang, Mo

    2013-01-01

    Many testing programs use automated scoring to grade essays. One issue in automated essay scoring that has not been examined adequately is population invariance and its causes. The primary purpose of this study was to investigate the impact of sampling in model calibration on population invariance of automated scores. This study analyzed scores…

  11. Direct analysis of textile dyes from trace fibers by automated microfluidics extraction system coupled with Q-TOF mass spectrometer for forensic applications.

    PubMed

    Sultana, Nadia; Gunning, Sean; Furst, Stephen J; Garrard, Kenneth P; Dow, Thomas A; Vinueza, Nelson R

    2018-05-19

    Textile fiber is a common form of transferable trace evidence at the crime scene. Different techniques such as microscopy or spectroscopy are currently being used for trace fiber analysis. Dye characterization in trace fiber adds an important molecular specificity during the analysis. In this study, we performed a direct trace fiber analysis method via dye characterization by a novel automated microfluidics device (MFD) dye extraction system coupled with a quadrupole-time-of-flight (Q-TOF) mass spectrometer (MS). The MFD system used an in-house made automated procedure which requires only 10μL of organic solvent for the extraction. The total extraction and identification time by the system is under 12min. A variety of sulfonated azo and anthraquinone dyes were analyzed from ∼1mm length nylon fiber samples. This methodology successfully characterized multiple dyes (≥3 dyes) from a single fiber thread. Additionally, it was possible to do dye characterization from single fibers with a diameter of ∼10μm. The MFD-MS system was used for elemental composition and isotopic distribution analysis where MFD-MS/MS was used for structural characterization of dyes on fibers. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Electronic Data Interchange: Using Technology to Exchange Transcripts.

    ERIC Educational Resources Information Center

    Stewart, John T.

    1994-01-01

    Describes the Florida Automated System for Transferring Educational Records (FASTER) project, which permits the electronic exchange of student transcripts; uses of similar electronic data interchange (EDI) programs in other states; and the national SPEEDE/ExPRESS project, which uses a standard format for transferring electronic transcripts.…

  13. Development of an automated high temperature valveless injection system for on-line gas chromatography

    NASA Astrophysics Data System (ADS)

    Kreisberg, N. M.; Worton, D. R.; Zhao, Y.; Isaacman, G.; Goldstein, A. H.; Hering, S. V.

    2014-07-01

    A reliable method of sample introduction is presented for on-line gas chromatography with a special application to in-situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a controlled pressure switching device that offers the advantage of long term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing the interface for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient detector and 15% accurate when applied to a vacuum based detector. Laboratory comparisons made between the two methods of sample introduction using a thermal desorption aerosol gas chromatograph (TAG) show approximately three times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in-situ instrument demonstrate minimal trending and a zero failure rate during field deployments ranging up to four weeks of continuous sampling. Extension of the VLI to dual collection cells is presented with less than 3% cell-to-cell carry-over.

  14. Automated dynamic liquid-liquid-liquid microextraction followed by high-performance liquid chromatography-ultraviolet detection for the determination of phenoxy acid herbicides in environmental waters.

    PubMed

    Wu, Jingming; Ee, Kim Huey; Lee, Hian Kee

    2005-08-05

    Automated dynamic liquid-liquid-liquid microextraction (D-LLLME) controlled by a programmable syringe pump and combined with HPLC-UV was investigated for the extraction and determination of 5 phenoxy acid herbicides in aqueous samples. In the extraction procedure, the acceptor phase was repeatedly withdrawn into and discharged from the hollow fiber by the syringe pump. The repetitive movement of acceptor phase into and out of the hollow fiber channel facilitated the transfer of analytes into donor phase, from the organic phase held in the pore of the fiber. Parameters such as the organic solvent, concentrations of the donor and acceptor phases, plunger movement pattern, speed of agitation and ionic strength of donor phase were evaluated. Good linearity of analytes was achieved in the range of 0.5-500 ng/ml with coefficients of determination, r2 > 0.9994. Good repeatabilities of extraction performance were obtained with relative standard deviations lower than 7.5%. The method provided up-to 490-fold enrichment within 13 min. In addition, the limits of detection (LODs) ranged from 0.1 to 0.4 ng/mL (S/N = 3). D-LLLME was successfully applied for the analysis of phenoxy acid herbicides from real environmental water samples.

  15. 78 FR 48913 - Agency Information Collection Activities: Submission to OMB for Reinstatement, Without Change, of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-12

    ... electronic funds transfer information to maintain its vendor (credit union) records to make electronic... maintain current electronic funds transfer data for its vendor (credit union) electronic routing and... the information on the respondents such as through the use of automated collection techniques or other...

  16. 77 FR 50146 - Agency Information Collection Activities: Extension, With Change, of an Existing Information...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-20

    ... Request ACTION: 60-day notice of information collection; 10-002; Electronic Funds Transfer Waiver Request... appropriate automated, electronic, mechanical, or other technological collection techniques or other forms of.... (2) Title of the Form/Collection: Electronic Funds Transfer Waiver Request. (3) Agency form number...

  17. The Automated Aircraft Rework System (AARS): A system integration approach

    NASA Technical Reports Server (NTRS)

    Benoit, Michael J.

    1994-01-01

    The Mercer Engineering Research Center (MERC), under contract to the United States Air Force (USAF) since 1989, has been actively involved in providing the Warner Robins Air Logistics Center (WR-ALC) with a robotic workcell designed to perform rework automated defastening and hole location/transfer operations on F-15 wings. This paper describes the activities required to develop and implement this workcell, known as the Automated Aircraft Rework System (AARS). AARS is scheduled to be completely installed and in operation at WR-ALC by September 1994.

  18. Automated Absorber Attachment for X-ray Microcalorimeter Arrays

    NASA Technical Reports Server (NTRS)

    Moseley, S.; Allen, Christine; Kilbourne, Caroline; Miller, Timothy M.; Costen, Nick; Schulte, Eric; Moseley, Samuel J.

    2007-01-01

    Our goal is to develop a method for the automated attachment of large numbers of absorber tiles to large format detector arrays. This development includes the fabrication of high quality, closely spaced HgTe absorber tiles that are properly positioned for pick-and-place by our FC150 flip chip bonder. The FC150 also transfers the appropriate minute amount of epoxy to the detectors for permanent attachment of the absorbers. The success of this development will replace an arduous, risky and highly manual task with a reliable, high-precision automated process.

  19. Migration monitoring with automated technology

    Treesearch

    Rhonda L. Millikin

    2005-01-01

    Automated technology can supplement ground-based methods of migration monitoring by providing: (1) unbiased and automated sampling; (2) independent validation of current methods; (3) a larger sample area for landscape-level analysis of habitat selection for stopover, and (4) an opportunity to study flight behavior. In particular, radar-acoustic sensor fusion can...

  20. AUTOMATED SOLID PHASE EXTRACTION GC/MS FOR ANALYSIS OF SEMIVOLATILES IN WATER AND SEDIMENTS

    EPA Science Inventory

    Data is presented on the development of a new automated system combining solid phase extraction (SPE) with GC/MS spectrometry for the single-run analysis of water samples containing a broad range of organic compounds. The system uses commercially available automated in-line sampl...

  1. Biomek 3000: the workhorse in an automated accredited forensic genetic laboratory.

    PubMed

    Stangegaard, Michael; Meijer, Per-Johan; Børsting, Claus; Hansen, Anders J; Morling, Niels

    2012-10-01

    We have implemented and validated automated protocols for a wide range of processes such as sample preparation, PCR setup, and capillary electrophoresis setup using small, simple, and inexpensive automated liquid handlers. The flexibility and ease of programming enable the Biomek 3000 to be used in many parts of the laboratory process in a modern forensic genetics laboratory with low to medium sample throughput. In conclusion, we demonstrated that sample processing for accredited forensic genetic DNA typing can be implemented on small automated liquid handlers, leading to the reduction of manual work as well as increased quality and throughput.

  2. Automated cell disruption is a reliable and effective method of isolating RNA from fresh snap-frozen normal and malignant oral mucosa samples.

    PubMed

    Van der Vorst, Sébastien; Dekairelle, Anne-France; Irenge, Léonid; Hamoir, Marc; Robert, Annie; Gala, Jean-Luc

    2009-01-01

    This study compared automated vs. manual tissue grinding in terms of RNA yield obtained from oral mucosa biopsies. A total of 20 patients undergoing uvulectomy for sleep-related disorders and 10 patients undergoing biopsy for head and neck squamous cell carcinoma were enrolled in the study. Samples were collected, snap-frozen in liquid nitrogen, and divided into two parts of similar weight. Sample grinding was performed on one sample from each pair, either manually or using an automated cell disruptor. The performance and efficacy of each homogenization approach was compared in terms of total RNA yield (spectrophotometry, fluorometry), mRNA quantity [densitometry of specific TP53 amplicons and TP53 quantitative reverse-transcribed real-time PCR (qRT-PCR)], and mRNA quality (functional analysis of separated alleles in yeast). Although spectrophotometry and fluorometry results were comparable for both homogenization methods, TP53 expression values obtained by amplicon densitometry and qRT-PCR were significantly and consistently better after automated homogenization (p<0.005) for both uvula and tumor samples. Functional analysis of separated alleles in yeast results was better with the automated technique for tumor samples. Automated tissue homogenization appears to be a versatile, quick, and reliable method of cell disruption and is especially useful in the case of small malignant samples, which show unreliable results when processed by manual homogenization.

  3. Evaluation of an automated microplate technique in the Galileo system for ABO and Rh(D) blood grouping.

    PubMed

    Xu, Weiyi; Wan, Feng; Lou, Yufeng; Jin, Jiali; Mao, Weilin

    2014-01-01

    A number of automated devices for pretransfusion testing have recently become available. This study evaluated the Immucor Galileo System, a fully automated device based on the microplate hemagglutination technique for ABO/Rh (D) determinations. Routine ABO/Rh typing tests were performed on 13,045 samples using the Immucor automated instruments. Manual tube method was used to resolve ABO forward and reverse grouping discrepancies. D-negative test results were investigated and confirmed manually by the indirect antiglobulin test (IAT). The system rejected 70 tests for sample inadequacy. 87 samples were read as "No-type-determined" due to forward and reverse grouping discrepancies. 25 tests gave these results because of sample hemolysis. After further tests, we found 34 tests were caused by weakened RBC antibodies, 5 tests were attributable to weak A and/or B antigens, 4 tests were due to mixed-field reactions, and 8 tests had high titer cold agglutinin with blood qualifications which react only at temperatures below 34 degrees C. In the remaining 11 cases, irregular RBC antibodies were identified in 9 samples (seven anti-M and two anti-P) and two subgroups were identified in 2 samples (one A1 and one A2) by a reference laboratory. As for D typing, 2 weak D+ samples missed by automated systems gave negative results, but weak-positive reactions were observed in the IAT. The Immucor Galileo System is reliable and suited for ABO and D blood groups, some reasons may cause a discrepancy in ABO/D typing using a fully automated system. It is suggested that standardization of sample collection may improve the performance of the fully automated system.

  4. Signal Delay Stability of a Ku-Band Two-Way Satellite Time Transfer Terminal

    NASA Technical Reports Server (NTRS)

    Kirchner, Dieter; Robnik, R.

    1996-01-01

    A fully automated two-way time and frequency transfer (TWSTFT) system including a satellite simulator, which allows the user to carry out signal delay measurements in conjunction with each time transfer measurement, is operated at the Technical University of Graz (TUG). After a brief description of the system, results obtained during fifteen months of operation are presented and discussed. Finally, envisaged experiments are mentioned.

  5. Risk management: correct patient and specimen identification in a surgical pathology laboratory. The experience of Infermi Hospital, Rimini, Italy.

    PubMed

    Fabbretti, G

    2010-06-01

    Because of its complex nature, surgical pathology practice is prone to error. In this report, we describe our methods for reducing error as much as possible during the pre-analytical and analytical phases. This was achieved by revising procedures, and by using computer technology and automation. Most mistakes are the result of human error in the identification and matching of patient and samples. To avoid faulty data interpretation, we employed a new comprehensive computer system that acquires all patient ID information directly from the hospital's database with a remote order entry; it also provides label and request forms via-Web where clinical information is required before sending the sample. Both patient and sample are identified directly and immediately at the site where the surgical procedures are performed. Barcode technology is used to input information at every step and automation is used for sample blocks and slides to avoid errors that occur when information is recorded or transferred by hand. Quality control checks occur at every step of the process to ensure that none of the steps are left to chance and that no phase is dependent on a single operator. The system also provides statistical analysis of errors so that new strategies can be implemented to avoid repetition. In addition, the staff receives frequent training on avoiding errors and new developments. The results have been shown promising results with a very low error rate (0.27%). None of these compromised patient health and all errors were detected before the release of the diagnosis report.

  6. Industrializing electrophysiology: HT automated patch clamp on SyncroPatch® 96 using instant frozen cells.

    PubMed

    Polonchuk, Liudmila

    2014-01-01

    Patch-clamping is a powerful technique for investigating the ion channel function and regulation. However, its low throughput hampered profiling of large compound series in early drug development. Fortunately, automation has revolutionized the area of experimental electrophysiology over the past decade. Whereas the first automated patch-clamp instruments using the planar patch-clamp technology demonstrated rather a moderate throughput, few second-generation automated platforms recently launched by various companies have significantly increased ability to form a high number of high-resistance seals. Among them is SyncroPatch(®) 96 (Nanion Technologies GmbH, Munich, Germany), a fully automated giga-seal patch-clamp system with the highest throughput on the market. By recording from up to 96 cells simultaneously, the SyncroPatch(®) 96 allows to substantially increase throughput without compromising data quality. This chapter describes features of the innovative automated electrophysiology system and protocols used for a successful transfer of the established hERG assay to this high-throughput automated platform.

  7. Effects of automation of information-processing functions on teamwork.

    PubMed

    Wright, Melanie C; Kaber, David B

    2005-01-01

    We investigated the effects of automation as applied to different stages of information processing on team performance in a complex decision-making task. Forty teams of 2 individuals performed a simulated Theater Defense Task. Four automation conditions were simulated with computer assistance applied to realistic combinations of information acquisition, information analysis, and decision selection functions across two levels of task difficulty. Multiple measures of team effectiveness and team coordination were used. Results indicated different forms of automation have different effects on teamwork. Compared with a baseline condition, an increase in automation of information acquisition led to an increase in the ratio of information transferred to information requested; an increase in automation of information analysis resulted in higher team coordination ratings; and automation of decision selection led to better team effectiveness under low levels of task difficulty but at the cost of higher workload. The results support the use of early and intermediate forms of automation related to acquisition and analysis of information in the design of team tasks. Decision-making automation may provide benefits in more limited contexts. Applications of this research include the design and evaluation of automation in team environments.

  8. A New Automated Method and Sample Data Flow for Analysis of Volatile Nitrosamines in Human Urine*

    PubMed Central

    Hodgson, James A.; Seyler, Tiffany H.; McGahee, Ernest; Arnstein, Stephen; Wang, Lanqing

    2016-01-01

    Volatile nitrosamines (VNAs) are a group of compounds classified as probable (group 2A) and possible (group 2B) carcinogens in humans. Along with certain foods and contaminated drinking water, VNAs are detected at high levels in tobacco products and in both mainstream and sidestream smoke. Our laboratory monitors six urinary VNAs—N-nitrosodimethylamine (NDMA), N-nitrosomethylethylamine (NMEA), N-nitrosodiethylamine (NDEA), N-nitrosopiperidine (NPIP), N-nitrosopyrrolidine (NPYR), and N-nitrosomorpholine (NMOR)—using isotope dilution GC-MS/MS (QQQ) for large population studies such as the National Health and Nutrition Examination Survey (NHANES). In this paper, we report for the first time a new automated sample preparation method to more efficiently quantitate these VNAs. Automation is done using Hamilton STAR™ and Caliper Staccato™ workstations. This new automated method reduces sample preparation time from 4 hours to 2.5 hours while maintaining precision (inter-run CV < 10%) and accuracy (85% - 111%). More importantly this method increases sample throughput while maintaining a low limit of detection (<10 pg/mL) for all analytes. A streamlined sample data flow was created in parallel to the automated method, in which samples can be tracked from receiving to final LIMs output with minimal human intervention, further minimizing human error in the sample preparation process. This new automated method and the sample data flow are currently applied in bio-monitoring of VNAs in the US non-institutionalized population NHANES 2013-2014 cycle. PMID:26949569

  9. 21 CFR 864.5200 - Automated cell counter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated cell counter. 864.5200 Section 864.5200....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the...

  10. 21 CFR 864.5240 - Automated blood cell diluting apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated blood cell diluting apparatus. 864.5240... § 864.5240 Automated blood cell diluting apparatus. (a) Identification. An automated blood cell diluting apparatus is a fully automated or semi-automated device used to make appropriate dilutions of a blood sample...

  11. 21 CFR 864.5240 - Automated blood cell diluting apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated blood cell diluting apparatus. 864.5240... § 864.5240 Automated blood cell diluting apparatus. (a) Identification. An automated blood cell diluting apparatus is a fully automated or semi-automated device used to make appropriate dilutions of a blood sample...

  12. Orbit transfer rocket engine technology program: Automated preflight methods concept definition

    NASA Technical Reports Server (NTRS)

    Erickson, C. M.; Hertzberg, D. W.

    1991-01-01

    The possibility of automating preflight engine checkouts on orbit transfer engines is discussed. The minimum requirements in terms of information and processing necessary to assess the engine'e integrity and readiness to perform its mission were first defined. A variety of ways for remotely obtaining that information were generated. The sophistication of these approaches varied from a simple preliminary power up, where the engine is fired up for the first time, to the most advanced approach where the sensor and operational history data system alone indicates engine integrity. The critical issues and benefits of these methods were identified, outlined, and prioritized. The technology readiness of each of these automated preflight methods were then rated on a NASA Office of Exploration scale used for comparing technology options for future mission choices. Finally, estimates were made of the remaining cost to advance the technology for each method to a level where the system validation models have been demonstrated in a simulated environment.

  13. [Establishment of Automation System for Detection of Alcohol in Blood].

    PubMed

    Tian, L L; Shen, Lei; Xue, J F; Liu, M M; Liang, L J

    2017-02-01

    To establish an automation system for detection of alcohol content in blood. The determination was performed by automated workstation of extraction-headspace gas chromatography (HS-GC). The blood collection with negative pressure, sealing time of headspace bottle and sample needle were checked and optimized in the abstraction of automation system. The automatic sampling was compared with the manual sampling. The quantitative data obtained by the automated workstation of extraction-HS-GC for alcohol was stable. The relative differences of two parallel samples were less than 5%. The automated extraction was superior to the manual extraction. A good linear relationship was obtained at the alcohol concentration range of 0.1-3.0 mg/mL ( r ≥0.999) with good repeatability. The method is simple and quick, with more standard experiment process and accurate experimental data. It eliminates the error from the experimenter and has good repeatability, which can be applied to the qualitative and quantitative detections of alcohol in blood. Copyright© by the Editorial Department of Journal of Forensic Medicine

  14. A Highly Flexible, Automated System Providing Reliable Sample Preparation in Element- and Structure-Specific Measurements.

    PubMed

    Vorberg, Ellen; Fleischer, Heidi; Junginger, Steffen; Liu, Hui; Stoll, Norbert; Thurow, Kerstin

    2016-10-01

    Life science areas require specific sample pretreatment to increase the concentration of the analytes and/or to convert the analytes into an appropriate form for the detection and separation systems. Various workstations are commercially available, allowing for automated biological sample pretreatment. Nevertheless, due to the required temperature, pressure, and volume conditions in typical element and structure-specific measurements, automated platforms are not suitable for analytical processes. Thus, the purpose of the presented investigation was the design, realization, and evaluation of an automated system ensuring high-precision sample preparation for a variety of analytical measurements. The developed system has to enable system adaption and high performance flexibility. Furthermore, the system has to be capable of dealing with the wide range of required vessels simultaneously, allowing for less cost and time-consuming process steps. However, the system's functionality has been confirmed in various validation sequences. Using element-specific measurements, the automated system was up to 25% more precise compared to the manual procedure and as precise as the manual procedure using structure-specific measurements. © 2015 Society for Laboratory Automation and Screening.

  15. Children of the Four Winds: The Migrant Student Record Transfer System.

    ERIC Educational Resources Information Center

    Dyer, Maxwell

    A discussion of the computerized Migrant Student Record Transfer System (MSRTS) is presented. The author first describes it as a functional automated system, headquartered in the Arkansas Department of Education, which serves the record transferral needs of seasonal farm migrant children as they move throughout the contiguous 48 states.…

  16. 78 FR 59375 - Agency Information Collection Activities: Submission to OMB for Reinstatement, Without Change, of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-26

    ... transfer information to maintain its vendor (credit union) records to make electronic payments to credit... current electronic funds transfer data for its vendor (credit union) electronic routing and transit data... such as through the use of automated collection techniques or other forms of information technology. It...

  17. Automated Microflow NMR: Routine Analysis of Five-Microliter Samples

    PubMed Central

    Jansma, Ariane; Chuan, Tiffany; Geierstanger, Bernhard H.; Albrecht, Robert W.; Olson, Dean L.; Peck, Timothy L.

    2006-01-01

    A microflow CapNMR probe double-tuned for 1H and 13C was installed on a 400-MHz NMR spectrometer and interfaced to an automated liquid handler. Individual samples dissolved in DMSO-d6 are submitted for NMR analysis in vials containing as little as 10 μL of sample. Sets of samples are submitted in a low-volume 384-well plate. Of the 10 μL of sample per well, as with vials, 5 μL is injected into the microflow NMR probe for analysis. For quality control of chemical libraries, 1D NMR spectra are acquired under full automation from 384-well plates on as many as 130 compounds within 24 h using 128 scans per spectrum and a sample-to-sample cycle time of ∼11 min. Because of the low volume requirements and high mass sensitivity of the microflow NMR system, 30 nmol of a typical small molecule is sufficient to obtain high-quality, well-resolved, 1D proton or 2D COSY NMR spectra in ∼6 or 20 min of data acquisition time per experiment, respectively. Implementation of pulse programs with automated solvent peak identification and suppression allow for reliable data collection, even for samples submitted in fully protonated DMSO. The automated microflow NMR system is controlled and monitored using web-based software. PMID:16194121

  18. The Stanford Automated Mounter: Pushing the limits of sample exchange at the SSRL macromolecular crystallography beamlines

    DOE PAGES

    Russi, Silvia; Song, Jinhu; McPhillips, Scott E.; ...

    2016-02-24

    The Stanford Automated Mounter System, a system for mounting and dismounting cryo-cooled crystals, has been upgraded to increase the throughput of samples on the macromolecular crystallography beamlines at the Stanford Synchrotron Radiation Lightsource. This upgrade speeds up robot maneuvers, reduces the heating/drying cycles, pre-fetches samples and adds an air-knife to remove frost from the gripper arms. As a result, sample pin exchange during automated crystal quality screening now takes about 25 s, five times faster than before this upgrade.

  19. The Stanford Automated Mounter: Pushing the limits of sample exchange at the SSRL macromolecular crystallography beamlines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russi, Silvia; Song, Jinhu; McPhillips, Scott E.

    The Stanford Automated Mounter System, a system for mounting and dismounting cryo-cooled crystals, has been upgraded to increase the throughput of samples on the macromolecular crystallography beamlines at the Stanford Synchrotron Radiation Lightsource. This upgrade speeds up robot maneuvers, reduces the heating/drying cycles, pre-fetches samples and adds an air-knife to remove frost from the gripper arms. As a result, sample pin exchange during automated crystal quality screening now takes about 25 s, five times faster than before this upgrade.

  20. The use of automation and robotic systems to establish and maintain lunar base operations

    NASA Technical Reports Server (NTRS)

    Petrosky, Lyman J.

    1992-01-01

    Robotic systems provide a means of performing many of the operations required to establish and maintain a lunar base. They form a synergistic system when properly used in concert with human activities. This paper discusses the various areas where robotics and automation may be used to enhance lunar base operations. Robots are particularly well suited for surface operations (exterior to the base habitat modules) because they can be designed to operate in the extreme temperatures and vacuum conditions of the Moon (or Mars). In this environment, the capabilities of semi-autonomous robots would surpass that of humans in all but the most complex tasks. Robotic surface operations include such activities as long range geological and mineralogical surveys with sample return, materials movement in and around the base, construction of radiation barriers around habitats, transfer of materials over large distances, and construction of outposts. Most of the above operations could be performed with minor modifications to a single basic robotic rover. Within the lunar base habitats there are a few areas where robotic operations would be preferable to human operations. Such areas include routine inspections for leakage in the habitat and its systems, underground transfer of materials between habitats, and replacement of consumables. In these and many other activities, robotic systems will greatly enhance lunar base operations. The robotic systems described in this paper are based on what is realistically achievable with relatively near term technology. A lunar base can be built and maintained if we are willing.

  1. Establishing a novel automated magnetic bead-based method for the extraction of DNA from a variety of forensic samples.

    PubMed

    Witt, Sebastian; Neumann, Jan; Zierdt, Holger; Gébel, Gabriella; Röscheisen, Christiane

    2012-09-01

    Automated systems have been increasingly utilized for DNA extraction by many forensic laboratories to handle growing numbers of forensic casework samples while minimizing the risk of human errors and assuring high reproducibility. The step towards automation however is not easy: The automated extraction method has to be very versatile to reliably prepare high yields of pure genomic DNA from a broad variety of sample types on different carrier materials. To prevent possible cross-contamination of samples or the loss of DNA, the components of the kit have to be designed in a way that allows for the automated handling of the samples with no manual intervention necessary. DNA extraction using paramagnetic particles coated with a DNA-binding surface is predestined for an automated approach. For this study, we tested different DNA extraction kits using DNA-binding paramagnetic particles with regard to DNA yield and handling by a Freedom EVO(®)150 extraction robot (Tecan) equipped with a Te-MagS magnetic separator. Among others, the extraction kits tested were the ChargeSwitch(®)Forensic DNA Purification Kit (Invitrogen), the PrepFiler™Automated Forensic DNA Extraction Kit (Applied Biosystems) and NucleoMag™96 Trace (Macherey-Nagel). After an extensive test phase, we established a novel magnetic bead extraction method based upon the NucleoMag™ extraction kit (Macherey-Nagel). The new method is readily automatable and produces high yields of DNA from different sample types (blood, saliva, sperm, contact stains) on various substrates (filter paper, swabs, cigarette butts) with no evidence of a loss of magnetic beads or sample cross-contamination. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. A Robotic Platform for Corn Seedling Morphological Traits Characterization

    PubMed Central

    Lu, Hang; Tang, Lie; Whitham, Steven A.; Mei, Yu

    2017-01-01

    Crop breeding plays an important role in modern agriculture, improving plant performance, and increasing yield. Identifying the genes that are responsible for beneficial traits greatly facilitates plant breeding efforts for increasing crop production. However, associating genes and their functions with agronomic traits requires researchers to observe, measure, record, and analyze phenotypes of large numbers of plants, a repetitive and error-prone job if performed manually. An automated seedling phenotyping system aimed at replacing manual measurement, reducing sampling time, and increasing the allowable work time is thus highly valuable. Toward this goal, we developed an automated corn seedling phenotyping platform based on a time-of-flight of light (ToF) camera and an industrial robot arm. A ToF camera is mounted on the end effector of the robot arm. The arm positions the ToF camera at different viewpoints for acquiring 3D point cloud data. A camera-to-arm transformation matrix was calculated using a hand-eye calibration procedure and applied to transfer different viewpoints into an arm-based coordinate frame. Point cloud data filters were developed to remove the noise in the background and in the merged seedling point clouds. A 3D-to-2D projection and an x-axis pixel density distribution method were used to segment the stem and leaves. Finally, separated leaves were fitted with 3D curves for morphological traits characterization. This platform was tested on a sample of 60 corn plants at their early growth stages with between two to five leaves. The error ratios of the stem height and leave length measurements are 13.7% and 13.1%, respectively, demonstrating the feasibility of this robotic system for automated corn seedling phenotyping. PMID:28895892

  3. A Robotic Platform for Corn Seedling Morphological Traits Characterization.

    PubMed

    Lu, Hang; Tang, Lie; Whitham, Steven A; Mei, Yu

    2017-09-12

    Crop breeding plays an important role in modern agriculture, improving plant performance, and increasing yield. Identifying the genes that are responsible for beneficial traits greatly facilitates plant breeding efforts for increasing crop production. However, associating genes and their functions with agronomic traits requires researchers to observe, measure, record, and analyze phenotypes of large numbers of plants, a repetitive and error-prone job if performed manually. An automated seedling phenotyping system aimed at replacing manual measurement, reducing sampling time, and increasing the allowable work time is thus highly valuable. Toward this goal, we developed an automated corn seedling phenotyping platform based on a time-of-flight of light (ToF) camera and an industrial robot arm. A ToF camera is mounted on the end effector of the robot arm. The arm positions the ToF camera at different viewpoints for acquiring 3D point cloud data. A camera-to-arm transformation matrix was calculated using a hand-eye calibration procedure and applied to transfer different viewpoints into an arm-based coordinate frame. Point cloud data filters were developed to remove the noise in the background and in the merged seedling point clouds. A 3D-to-2D projection and an x -axis pixel density distribution method were used to segment the stem and leaves. Finally, separated leaves were fitted with 3D curves for morphological traits characterization. This platform was tested on a sample of 60 corn plants at their early growth stages with between two to five leaves. The error ratios of the stem height and leave length measurements are 13.7% and 13.1%, respectively, demonstrating the feasibility of this robotic system for automated corn seedling phenotyping.

  4. Rapid enumeration of low numbers of moulds in tea based drinks using an automated system.

    PubMed

    Tanaka, Kouichi; Yamaguchi, Nobuyasu; Baba, Takashi; Amano, Norihide; Nasu, Masao

    2011-01-31

    Aseptically prepared cold drinks based on tea have become popular worldwide. Contamination of these drinks with harmful microbes is a potential health problem because such drinks are kept free from preservatives to maximize aroma and flavour. Heat-tolerant conidia and ascospores of fungi can survive pasteurization, and need to be detected as quickly as possible. We were able to rapidly and accurately detect low numbers of conidia and ascospores in tea-based drinks using fluorescent staining followed by an automated counting system. Conidia or ascospores were inoculated into green tea and oolong tea, and samples were immediately filtered through nitrocellulose membranes (pore size: 0.8 μm) to concentrate fungal propagules. These were transferred onto potato dextrose agar and incubated for 23 h at 28 °C. Fungi germinating on the membranes were fluorescently stained for 30 min. The stained mycelia were counted selectively within 90s using an automated counting system (MGS-10LD; Chuo Electric Works, Osaka, Japan). Very low numbers (1 CFU/100ml) of conidia or ascospores could be rapidly counted, in contrast to traditional labour intensive techniques. All tested mould strains were detected within 24h while conventional plate counting required 72 h for colony enumeration. Counts of slow-growing fungi (Cladosporium cladosporioides) obtained by automated counting and by conventional plate counting were close (r(2) = 0.986). Our combination of methods enables counting of both fast- and slow-growing fungi, and should be useful for microbiological quality control of tea-based and also other drinks. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. 21 CFR 864.5200 - Automated cell counter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the patient's peripheral blood (blood circulating in one of the body's extremities, such as the arm). These...

  6. 21 CFR 864.5200 - Automated cell counter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the patient's peripheral blood (blood circulating in one of the body's extremities, such as the arm). These...

  7. 21 CFR 864.5200 - Automated cell counter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the patient's peripheral blood (blood circulating in one of the body's extremities, such as the arm). These...

  8. 21 CFR 864.5200 - Automated cell counter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the patient's peripheral blood (blood circulating in one of the body's extremities, such as the arm). These...

  9. Nonanalytic Laboratory Automation: A Quarter Century of Progress.

    PubMed

    Hawker, Charles D

    2017-06-01

    Clinical laboratory automation has blossomed since the 1989 AACC meeting, at which Dr. Masahide Sasaki first showed a western audience what his laboratory had implemented. Many diagnostics and other vendors are now offering a variety of automated options for laboratories of all sizes. Replacing manual processing and handling procedures with automation was embraced by the laboratory community because of the obvious benefits of labor savings and improvement in turnaround time and quality. Automation was also embraced by the diagnostics vendors who saw automation as a means of incorporating the analyzers purchased by their customers into larger systems in which the benefits of automation were integrated to the analyzers.This report reviews the options that are available to laboratory customers. These options include so called task-targeted automation-modules that range from single function devices that automate single tasks (e.g., decapping or aliquoting) to multifunction workstations that incorporate several of the functions of a laboratory sample processing department. The options also include total laboratory automation systems that use conveyors to link sample processing functions to analyzers and often include postanalytical features such as refrigerated storage and sample retrieval.Most importantly, this report reviews a recommended process for evaluating the need for new automation and for identifying the specific requirements of a laboratory and developing solutions that can meet those requirements. The report also discusses some of the practical considerations facing a laboratory in a new implementation and reviews the concept of machine vision to replace human inspections. © 2017 American Association for Clinical Chemistry.

  10. Economic and workflow analysis of a blood bank automated system.

    PubMed

    Shin, Kyung-Hwa; Kim, Hyung Hoi; Chang, Chulhun L; Lee, Eun Yup

    2013-07-01

    This study compared the estimated costs and times required for ABO/Rh(D) typing and unexpected antibody screening using an automated system and manual methods. The total cost included direct and labor costs. Labor costs were calculated on the basis of the average operator salaries and unit values (minutes), which was the hands-on time required to test one sample. To estimate unit values, workflows were recorded on video, and the time required for each process was analyzed separately. The unit values of ABO/Rh(D) typing using the manual method were 5.65 and 8.1 min during regular and unsocial working hours, respectively. The unit value was less than 3.5 min when several samples were tested simultaneously. The unit value for unexpected antibody screening was 2.6 min. The unit values using the automated method for ABO/Rh(D) typing, unexpected antibody screening, and both simultaneously were all 1.5 min. The total cost of ABO/Rh(D) typing of only one sample using the automated analyzer was lower than that of testing only one sample using the manual technique but higher than that of testing several samples simultaneously. The total cost of unexpected antibody screening using an automated analyzer was less than that using the manual method. ABO/Rh(D) typing using an automated analyzer incurs a lower unit value and cost than that using the manual technique when only one sample is tested at a time. Unexpected antibody screening using an automated analyzer always incurs a lower unit value and cost than that using the manual technique.

  11. Optimizing ELISAs for precision and robustness using laboratory automation and statistical design of experiments.

    PubMed

    Joelsson, Daniel; Moravec, Phil; Troutman, Matthew; Pigeon, Joseph; DePhillips, Pete

    2008-08-20

    Transferring manual ELISAs to automated platforms requires optimizing the assays for each particular robotic platform. These optimization experiments are often time consuming and difficult to perform using a traditional one-factor-at-a-time strategy. In this manuscript we describe the development of an automated process using statistical design of experiments (DOE) to quickly optimize immunoassays for precision and robustness on the Tecan EVO liquid handler. By using fractional factorials and a split-plot design, five incubation time variables and four reagent concentration variables can be optimized in a short period of time.

  12. Automation and robotics for the Space Station - The influence of the Advanced Technology Advisory Committee

    NASA Technical Reports Server (NTRS)

    Nunamaker, Robert R.; Willshire, Kelli F.

    1988-01-01

    The reports of a committee established by Congress to identify specific systems of the Space Station which would advance automation and robotics technologies are reviewed. The history of the committee, its relation to NASA, and the reports which it has released are discussed. The committee's reports recommend the widespread use of automation and robotics for the Space Station, a program for technology development and transfer between industries and research and development communities, and the planned use of robots to service and repair satellites and their payloads which are accessible from the Space Station.

  13. Development of an automated high-temperature valveless injection system for online gas chromatography

    NASA Astrophysics Data System (ADS)

    Kreisberg, N. M.; Worton, D. R.; Zhao, Y.; Isaacman, G.; Goldstein, A. H.; Hering, S. V.

    2014-12-01

    A reliable method of sample introduction is presented for online gas chromatography with a special application to in situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a valveless sample introduction interface that offers the advantage of long-term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing this pressure-switching-based device for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient-pressure detector and 15% accurate when applied to a vacuum-based detector. Laboratory comparisons made between the two methods of sample introduction using a thermal desorption aerosol gas chromatograph (TAG) show that the new interface has approximately 3 times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in situ instrument demonstrate typically less than 2% week-1 response trending and a zero failure rate during field deployments ranging up to 4 weeks of continuous sampling. Extension of the valveless interface to dual collection cells is presented with less than 3% cell-to-cell carryover.

  14. Development of an automated high-temperature valveless injection system for online gas chromatography

    DOE PAGES

    Kreisberg, N. M.; Worton, D. R.; Zhao, Y.; ...

    2014-12-12

    A reliable method of sample introduction is presented for online gas chromatography with a special application to in situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a valveless sample introduction interface that offers the advantage of long-term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing this pressure-switching-based device for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient-pressure detector and 15% accurate when applied to a vacuum-based detector. Laboratory comparisons made between the two methods of sample introductionmore » using a thermal desorption aerosol gas chromatograph (TAG) show that the new interface has approximately 3 times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in situ instrument demonstrate typically less than 2% week -1 response trending and a zero failure rate during field deployments ranging up to 4 weeks of continuous sampling. Extension of the valveless interface to dual collection cells is presented with less than 3% cell-to-cell carryover.« less

  15. Automated batch fiducial-less tilt-series alignment in Appion using Protomo

    PubMed Central

    Noble, Alex J.; Stagg, Scott M.

    2015-01-01

    The field of electron tomography has benefited greatly from manual and semi-automated approaches to marker-based tilt-series alignment that have allowed for the structural determination of multitudes of in situ cellular structures as well as macromolecular structures of individual protein complexes. The emergence of complementary metal-oxide semiconductor detectors capable of detecting individual electrons has enabled the collection of low dose, high contrast images, opening the door for reliable correlation-based tilt-series alignment. Here we present a set of automated, correlation-based tilt-series alignment, contrast transfer function (CTF) correction, and reconstruction workflows for use in conjunction with the Appion/Leginon package that are primarily targeted at automating structure determination with cryogenic electron microscopy. PMID:26455557

  16. The distribution of interstellar dust in CALIFA edge-on galaxies via oligochromatic radiative transfer fitting

    NASA Astrophysics Data System (ADS)

    De Geyter, Gert; Baes, Maarten; Camps, Peter; Fritz, Jacopo; De Looze, Ilse; Hughes, Thomas M.; Viaene, Sébastien; Gentile, Gianfranco

    2014-06-01

    We investigate the amount and spatial distribution of interstellar dust in edge-on spiral galaxies, using detailed radiative transfer modelling of a homogeneous sample of 12 galaxies selected from the Calar Alto Legacy Integral Field Area survey. Our automated fitting routine, FITSKIRT, was first validated against artificial data. This is done by simultaneously reproducing the Sloan Digital Sky Survey g-, r-, i- and z-band observations of a toy model in order to combine the information present in the different bands. We show that this combined, oligochromatic fitting has clear advantages over standard monochromatic fitting especially regarding constraints on the dust properties. We model all galaxies in our sample using a three-component model, consisting of a double-exponential disc to describe the stellar and dust discs and using a Sérsic profile to describe the central bulge. The full model contains 19 free parameters, and we are able to constrain all these parameters to a satisfactory level of accuracy without human intervention or strong boundary conditions. Apart from two galaxies, the entire sample can be accurately reproduced by our model. We find that the dust disc is about 75 per cent more extended but only half as high as the stellar disc. The average face-on optical depth in the V band is 0.76 and the spread of 0.60 within our sample is quite substantial, which indicates that some spiral galaxies are relatively opaque even when seen face-on.

  17. Understanding cross sample talk as a result of triboelectric charging on future mars missions

    NASA Astrophysics Data System (ADS)

    Beegle, L. W.; Anderson, R. C.; Fleming, G.

    2009-12-01

    Proper scientific analysis requires the material that is collected and analyzed by in-situ instruments be as close as possible (chemically and mineralogically) to the initial, unaltered surface material prior to its collection and delivery. However this is not always possible for automated robotic in situ analysis. Therefore it is vital to understanding how the sample has been changed/altered prior to analysis so that analysis can be put in the proper context. We have examined the transport of fines when transferred under ambient martian conditions in hardware analogous to that being developed for the Mars Science Laboratory (MSL) sample acquisition flight hardware. We will discuss the amount of cross sample contamination when different mineralogy’s are transferred under Martian environmental conditions. Similar issues have been identified as problems within the terrestrial mining, textile, and pharmaceutical research communities that may alter/change the chemical and mineralogical compositions of samples before they are delivered to the MSL Chemistry and Mineralogy (CheMin) and the Sample Analysis at Mars (SAM) analytical instruments. These cross-sample contamination will affect the overall quality of the science results and each of these processes need to be examined and understood prior to MSL landing on the surface of Mars. There are two forms of triboelectric charging that have been observed to occur on Earth and they are 1) when dissimilar material comes in contact (one material charges positive and the other negative depending on their relative positions on the triboelectric series and the work function of the material) and 2) when two similar materials come in contact, the larger particles can transfer one of their high energy electrons to a smaller particle. During the collisions, the transferred electron tends to lose energy and the charge tends not to move from the smaller particle back to the larger particle in further collisions. This transfer effect can occur multiple times on particles resulting in multiple charge states occurring on particles. While individual particles can have different charge sign, the bulk material can become charged due to contact of different minerals constituents in the sample and through contact of the wall. This results in a very complex system that has yet to be fully understood and characterized. We have begun to develop a characterize a data set which enable scientists to better relate arm and mast mounted measurements made on the surface by the Alpha Particle X-ray Spectrometer (APXS), the Mars Hand Lens Imager (MALHI), the Chemistry and Microimaging (ChemCam) and the Mast Camera (MastCam) instruments to the measurements made by the two onboard analytical instruments, CheMin and SAM after a sample is acquired, processed, and delivered.

  18. Automated quantitative cytological analysis using portable microfluidic microscopy.

    PubMed

    Jagannadh, Veerendra Kalyan; Murthy, Rashmi Sreeramachandra; Srinivasan, Rajesh; Gorthi, Sai Siva

    2016-06-01

    In this article, a portable microfluidic microscopy based approach for automated cytological investigations is presented. Inexpensive optical and electronic components have been used to construct a simple microfluidic microscopy system. In contrast to the conventional slide-based methods, the presented method employs microfluidics to enable automated sample handling and image acquisition. The approach involves the use of simple in-suspension staining and automated image acquisition to enable quantitative cytological analysis of samples. The applicability of the presented approach to research in cellular biology is shown by performing an automated cell viability assessment on a given population of yeast cells. Further, the relevance of the presented approach to clinical diagnosis and prognosis has been demonstrated by performing detection and differential assessment of malaria infection in a given sample. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Bacterial and fungal DNA extraction from blood samples: automated protocols.

    PubMed

    Lorenz, Michael G; Disqué, Claudia; Mühl, Helge

    2015-01-01

    Automation in DNA isolation is a necessity for routine practice employing molecular diagnosis of infectious agents. To this end, the development of automated systems for the molecular diagnosis of microorganisms directly in blood samples is at its beginning. Important characteristics of systems demanded for routine use include high recovery of microbial DNA, DNA-free containment for the reduction of DNA contamination from exogenous sources, DNA-free reagents and consumables, ideally a walkaway system, and economical pricing of the equipment and consumables. Such full automation of DNA extraction evaluated and in use for sepsis diagnostics is yet not available. Here, we present protocols for the semiautomated isolation of microbial DNA from blood culture and low- and high-volume blood samples. The protocols include a manual pretreatment step followed by automated extraction and purification of microbial DNA.

  20. Specimen coordinate automated measuring machine/fiducial automated measuring machine

    DOEpatents

    Hedglen, Robert E.; Jacket, Howard S.; Schwartz, Allan I.

    1991-01-01

    The Specimen coordinate Automated Measuring Machine (SCAMM) and the Fiducial Automated Measuring Machine (FAMM) is a computer controlled metrology system capable of measuring length, width, and thickness, and of locating fiducial marks. SCAMM and FAMM have many similarities in their designs, and they can be converted from one to the other without taking them out of the hot cell. Both have means for: supporting a plurality of samples and a standard; controlling the movement of the samples in the +/- X and Y directions; determining the coordinates of the sample; compensating for temperature effects; and verifying the accuracy of the measurements and repeating as necessary. SCAMM and FAMM are designed to be used in hot cells.

  1. ATV-3

    NASA Image and Video Library

    2012-04-06

    ISS030-E-210840 (6 April 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, enters the Automated Transfer Vehicle (ATV-3) currently docked with the International Space Station.

  2. Automated SEM and TEM sample preparation applied to copper/low k materials

    NASA Astrophysics Data System (ADS)

    Reyes, R.; Shaapur, F.; Griffiths, D.; Diebold, A. C.; Foran, B.; Raz, E.

    2001-01-01

    We describe the use of automated microcleaving for preparation of both SEM and TEM samples as done by SELA's new MC500 and TEMstation tools. The MC500 is an automated microcleaving tool that is capable of producing cleaves with 0.25 μm accuracy resulting in SEM-ready samples. The TEMstation is capable of taking a sample output from the MC500 (or from SELA's earlier MC200 tool) and producing a FIB ready slice of 25±5 μm, mounted on a TEM-washer and ready for FIB thinning to electron transparency for TEM analysis. The materials selected for the tool set evaluation mainly included the Cu/TaN/HOSP low-k system. The paper is divided into three sections, experimental approach, SEM preparation and analysis of HOSP low-k, and TEM preparation and analysis of Cu/TaN/HOSP low-k samples. For the samples discussed, data is presented to show the quality of preparation provided by these new automated tools.

  3. Asteroid exploration and utilization

    NASA Technical Reports Server (NTRS)

    Radovich, Brian M.; Carlson, Alan E.; Date, Medha D.; Duarte, Manny G.; Erian, Neil F.; Gafka, George K.; Kappler, Peter H.; Patano, Scott J.; Perez, Martin; Ponce, Edgar

    1992-01-01

    The Earth is nearing depletion of its natural resources at a time when human beings are rapidly expanding the frontiers of space. The resources possessed by asteroids have enormous potential for aiding and enhancing human space exploration as well as life on Earth. Project STONER (Systematic Transfer of Near Earth Resources) is based on mining an asteroid and transporting raw materials back to Earth. The asteroid explorer/sample return mission is designed in the context of both scenarios and is the first phase of a long range plan for humans to utilize asteroid resources. Project STONER is divided into two parts: asteroid selection and explorer spacecraft design. The spacecraft design team is responsible for the selection and integration of the subsystems: GNC, communications, automation, propulsion, power, structures, thermal systems, scientific instruments, and mechanisms used on the surface to retrieve and store asteroid regolith. The sample return mission scenario consists of eight primary phases that are critical to the mission.

  4. NASA Systems Autonomy Demonstration Project - Development of Space Station automation technology

    NASA Technical Reports Server (NTRS)

    Bull, John S.; Brown, Richard; Friedland, Peter; Wong, Carla M.; Bates, William

    1987-01-01

    A 1984 Congressional expansion of the 1958 National Aeronautics and Space Act mandated that NASA conduct programs, as part of the Space Station program, which will yield the U.S. material benefits, particularly in the areas of advanced automation and robotics systems. Demonstration programs are scheduled for automated systems such as the thermal control, expert system coordination of Station subsystems, and automation of multiple subsystems. The programs focus the R&D efforts and provide a gateway for transfer of technology to industry. The NASA Office of Aeronautics and Space Technology is responsible for directing, funding and evaluating the Systems Autonomy Demonstration Project, which will include simulated interactions between novice personnel and astronauts and several automated, expert subsystems to explore the effectiveness of the man-machine interface being developed. Features and progress on the TEXSYS prototype thermal control system expert system are outlined.

  5. Genomic Data Quality Impacts Automated Detection of Lateral Gene Transfer in Fungi

    PubMed Central

    Dupont, Pierre-Yves; Cox, Murray P.

    2017-01-01

    Lateral gene transfer (LGT, also known as horizontal gene transfer), an atypical mechanism of transferring genes between species, has almost become the default explanation for genes that display an unexpected composition or phylogeny. Numerous methods of detecting LGT events all rely on two fundamental strategies: primary structure composition or gene tree/species tree comparisons. Discouragingly, the results of these different approaches rarely coincide. With the wealth of genome data now available, detection of laterally transferred genes is increasingly being attempted in large uncurated eukaryotic datasets. However, detection methods depend greatly on the quality of the underlying genomic data, which are typically complex for eukaryotes. Furthermore, given the automated nature of genomic data collection, it is typically impractical to manually verify all protein or gene models, orthology predictions, and multiple sequence alignments, requiring researchers to accept a substantial margin of error in their datasets. Using a test case comprising plant-associated genomes across the fungal kingdom, this study reveals that composition- and phylogeny-based methods have little statistical power to detect laterally transferred genes. In particular, phylogenetic methods reveal extreme levels of topological variation in fungal gene trees, the vast majority of which show departures from the canonical species tree. Therefore, it is inherently challenging to detect LGT events in typical eukaryotic genomes. This finding is in striking contrast to the large number of claims for laterally transferred genes in eukaryotic species that routinely appear in the literature, and questions how many of these proposed examples are statistically well supported. PMID:28235827

  6. Airspace Technology Demonstration 3 (ATD-3): Dynamic Weather Routes (DWR) Technology Transfer Document Summary Version 1.0

    NASA Technical Reports Server (NTRS)

    Sheth, Kapil; Wang, Easter Mayan Chan

    2016-01-01

    Airspace Technology Demonstration #3 (ATD-3) is part of NASA's Airspace Operations and Safety Program (AOSP) - specifically, its Airspace Technology Demonstrations (ATD) Project. ATD-3 is a multiyear research and development effort which proposes to develop and demonstrate automation technologies and operating concepts that enable air navigation service providers and airspace users to continuously assess weather, winds, traffic, and other information to identify, evaluate, and implement workable opportunities for flight plan route corrections that can result in significant flight time and fuel savings in en route airspace. In order to ensure that the products of this tech-transfer are relevant and useful, NASA has created strong partnerships with the FAA and key industry stakeholders. This summary document and accompanying technology artifacts satisfy the first of three Research Transition Products (RTPs) defined in the Applied Traffic Flow Management (ATFM) Research Transition Team (RTT) Plan. This transfer consists of NASA's legacy Dynamic Weather Routes (DWR) work for efficient routing for en-route weather avoidance. DWR is a ground-based trajectory automation system that continuously and automatically analyzes active airborne aircraft in en route airspace to identify opportunities for simple corrections to flight plan routes that can save significant flying time, at least five minutes wind-corrected, while avoiding weather and considering traffic conflicts, airspace sector congestion, special use airspace, and FAA routing restrictions. The key benefit of the DWR concept is to let automation continuously and automatically analyze active flights to find those where simple route corrections can save significant time and fuel. Operators are busy during weather events. It is more effective to let automation find the opportunities for high-value route corrections.

  7. Flow through electrode with automated calibration

    DOEpatents

    Szecsody, James E [Richland, WA; Williams, Mark D [Richland, WA; Vermeul, Vince R [Richland, WA

    2002-08-20

    The present invention is an improved automated flow through electrode liquid monitoring system. The automated system has a sample inlet to a sample pump, a sample outlet from the sample pump to at least one flow through electrode with a waste port. At least one computer controls the sample pump and records data from the at least one flow through electrode for a liquid sample. The improvement relies upon (a) at least one source of a calibration sample connected to (b) an injection valve connected to said sample outlet and connected to said source, said injection valve further connected to said at least one flow through electrode, wherein said injection valve is controlled by said computer to select between said liquid sample or said calibration sample. Advantages include improved accuracy because of more frequent calibrations, no additional labor for calibration, no need to remove the flow through electrode(s), and minimal interruption of sampling.

  8. Analysis of energy dispersive x-ray diffraction profiles for material identification, imaging and system control

    NASA Astrophysics Data System (ADS)

    Cook, Emily Jane

    2008-12-01

    This thesis presents the analysis of low angle X-ray scatter measurements taken with an energy dispersive system for substance identification, imaging and system control. Diffraction measurements were made on illicit drugs, which have pseudo- crystalline structures and thus produce diffraction patterns comprising a se ries of sharp peaks. Though the diffraction profiles of each drug are visually characteristic, automated detection systems require a substance identification algorithm, and multivariate analysis was selected as suitable. The software was trained with measured diffraction data from 60 samples covering 7 illicit drugs and 5 common cutting agents, collected with a range of statistical qual ities and used to predict the content of 7 unknown samples. In all cases the constituents were identified correctly and the contents predicted to within 15%. Soft tissues exhibit broad peaks in their diffraction patterns. Diffraction data were collected from formalin fixed breast tissue samples and used to gen erate images. Maximum contrast between healthy and suspicious regions was achieved using momentum transfer windows 1.04-1.10 and 1.84-1.90 nm_1. The resulting images had an average contrast of 24.6% and 38.9% compared to the corresponding transmission X-ray images (18.3%). The data was used to simulate the feedback for an adaptive imaging system and the ratio of the aforementioned momentum transfer regions found to be an excellent pa rameter. Investigation into the effects of formalin fixation on human breast tissue and animal tissue equivalents indicated that fixation in standard 10% buffered formalin does not alter the diffraction profiles of tissue in the mo mentum transfer regions examined, though 100% unbuffered formalin affects the profile of porcine muscle tissue (a substitute for glandular and tumourous tissue), though fat is unaffected.

  9. Automated delay measurement system for an Earth station for Two-Way Satellite Time and Frequency Transfer

    NASA Technical Reports Server (NTRS)

    Dejong, Gerrit; Polderman, Michel C.

    1995-01-01

    The measurement of the difference of the transmit and receive delays of the signals in a Two-Way Satellite Time and Frequency Transfer (TWSTFT) Earth station is crucial for its nanosecond time transfer capability. Also, the monitoring of the change of this delay difference with time, temperature, humidity, or barometric pressure is important for improving the TWSTFT capabilities. An automated system for this purpose has been developed from the initial design at NMi-VSL. It calibrates separately the transmit and receive delays in cables, amplifiers, upconverters and downconverters, and antenna feeds. The obtained results can be applied as corrections to the TWSTFT measurement when, before and after a measurement session, a calibration session is performed. Preliminary results obtained at NMi-VSL will be shown. Also, if available, the results of a manual version of the system that is planned to be circulated in Sept. 1994 together with a USNO portable station on a calibration trip to European TWSTFT Earth stations.

  10. A robust ambient temperature collection and stabilization strategy: Enabling worldwide functional studies of the human microbiome

    PubMed Central

    Anderson, Ericka L.; Li, Weizhong; Klitgord, Niels; Highlander, Sarah K.; Dayrit, Mark; Seguritan, Victor; Yooseph, Shibu; Biggs, William; Venter, J. Craig; Nelson, Karen E.; Jones, Marcus B.

    2016-01-01

    As reports on possible associations between microbes and the host increase in number, more meaningful interpretations of this information require an ability to compare data sets across studies. This is dependent upon standardization of workflows to ensure comparability both within and between studies. Here we propose the standard use of an alternate collection and stabilization method that would facilitate such comparisons. The DNA Genotek OMNIgene∙Gut Stool Microbiome Kit was compared to the currently accepted community standard of freezing to store human stool samples prior to whole genome sequencing (WGS) for microbiome studies. This stabilization and collection device allows for ambient temperature storage, automation, and ease of shipping/transfer of samples. The device permitted the same data reproducibility as with frozen samples, and yielded higher recovery of nucleic acids. Collection and stabilization of stool microbiome samples with the DNA Genotek collection device, combined with our extraction and WGS, provides a robust, reproducible workflow that enables standardized global collection, storage, and analysis of stool for microbiome studies. PMID:27558918

  11. AUTOMATED ANALYSIS OF AQUEOUS SAMPLES CONTAINING PESTICIDES, ACIDIC/BASIC/NEUTRAL SEMIVOLATILES AND VOLATILE ORGANIC COMPOUNDS BY SOLID PHASE EXTRACTION COUPLED IN-LINE TO LARGE VOLUME INJECTION GC/MS

    EPA Science Inventory

    Data is presented on the development of a new automated system combining solid phase extraction (SPE) with GC/MS spectrometry for the single-run analysis of water samples containing a broad range of organic compounds. The system uses commercially available automated in-line 10-m...

  12. Comparison study of membrane filtration direct count and an automated coliform and Escherichia coli detection system for on-site water quality testing.

    PubMed

    Habash, Marc; Johns, Robert

    2009-10-01

    This study compared an automated Escherichia coli and coliform detection system with the membrane filtration direct count technique for water testing. The automated instrument performed equal to or better than the membrane filtration test in analyzing E. coli-spiked samples and blind samples with interference from Proteus vulgaris or Aeromonas hydrophila.

  13. The Upgrade Programme for the Structural Biology beamlines at the European Synchrotron Radiation Facility - High throughput sample evaluation and automation

    NASA Astrophysics Data System (ADS)

    Theveneau, P.; Baker, R.; Barrett, R.; Beteva, A.; Bowler, M. W.; Carpentier, P.; Caserotto, H.; de Sanctis, D.; Dobias, F.; Flot, D.; Guijarro, M.; Giraud, T.; Lentini, M.; Leonard, G. A.; Mattenet, M.; McCarthy, A. A.; McSweeney, S. M.; Morawe, C.; Nanao, M.; Nurizzo, D.; Ohlsson, S.; Pernot, P.; Popov, A. N.; Round, A.; Royant, A.; Schmid, W.; Snigirev, A.; Surr, J.; Mueller-Dieckmann, C.

    2013-03-01

    Automation and advances in technology are the key elements in addressing the steadily increasing complexity of Macromolecular Crystallography (MX) experiments. Much of this complexity is due to the inter-and intra-crystal heterogeneity in diffraction quality often observed for crystals of multi-component macromolecular assemblies or membrane proteins. Such heterogeneity makes high-throughput sample evaluation an important and necessary tool for increasing the chances of a successful structure determination. The introduction at the ESRF of automatic sample changers in 2005 dramatically increased the number of samples that were tested for diffraction quality. This "first generation" of automation, coupled with advances in software aimed at optimising data collection strategies in MX, resulted in a three-fold increase in the number of crystal structures elucidated per year using data collected at the ESRF. In addition, sample evaluation can be further complemented using small angle scattering experiments on the newly constructed bioSAXS facility on BM29 and the micro-spectroscopy facility (ID29S). The construction of a second generation of automated facilities on the MASSIF (Massively Automated Sample Screening Integrated Facility) beam lines will build on these advances and should provide a paradigm shift in how MX experiments are carried out which will benefit the entire Structural Biology community.

  14. Automated biowaste sampling system improved feces collection, mass measurement and sampling. [by use of a breadboard model

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Young, R.

    1974-01-01

    The capability of the basic automated Biowaste Sampling System (ABSS) hardware was extended and improved through the design, fabrication and test of breadboard hardware. A preliminary system design effort established the feasibility of integrating the breadboard concepts into the ABSS.

  15. Turbidity-controlled sampling for suspended sediment load estimation

    Treesearch

    Jack Lewis

    2003-01-01

    Abstract - Automated data collection is essential to effectively measure suspended sediment loads in storm events, particularly in small basins. Continuous turbidity measurements can be used, along with discharge, in an automated system that makes real-time sampling decisions to facilitate sediment load estimation. The Turbidity Threshold Sampling method distributes...

  16. [DNA Extraction from Old Bones by AutoMate Express™ System].

    PubMed

    Li, B; Lü, Z

    2017-08-01

    To establish a method for extracting DNA from old bones by AutoMate Express™ system. Bones were grinded into powder by freeze-mill. After extraction by AutoMate Express™, DNA were amplified and genotyped by Identifiler®Plus and MinFiler™ kits. DNA were extracted from 10 old bone samples, which kept in different environments with the postmortem interval from 10 to 20 years, in 3 hours by AutoMate Express™ system. Complete STR typing results were obtained from 8 samples. AutoMate Express™ system can quickly and efficiently extract DNA from old bones, which can be applied in forensic practice. Copyright© by the Editorial Department of Journal of Forensic Medicine

  17. Invention and validation of an automated camera system that uses optical character recognition to identify patient name mislabeled samples.

    PubMed

    Hawker, Charles D; McCarthy, William; Cleveland, David; Messinger, Bonnie L

    2014-03-01

    Mislabeled samples are a serious problem in most clinical laboratories. Published error rates range from 0.39/1000 to as high as 1.12%. Standardization of bar codes and label formats has not yet achieved the needed improvement. The mislabel rate in our laboratory, although low compared with published rates, prompted us to seek a solution to achieve zero errors. To reduce or eliminate our mislabeled samples, we invented an automated device using 4 cameras to photograph the outside of a sample tube. The system uses optical character recognition (OCR) to look for discrepancies between the patient name in our laboratory information system (LIS) vs the patient name on the customer label. All discrepancies detected by the system's software then require human inspection. The system was installed on our automated track and validated with production samples. We obtained 1 009 830 images during the validation period, and every image was reviewed. OCR passed approximately 75% of the samples, and no mislabeled samples were passed. The 25% failed by the system included 121 samples actually mislabeled by patient name and 148 samples with spelling discrepancies between the patient name on the customer label and the patient name in our LIS. Only 71 of the 121 mislabeled samples detected by OCR were found through our normal quality assurance process. We have invented an automated camera system that uses OCR technology to identify potential mislabeled samples. We have validated this system using samples transported on our automated track. Full implementation of this technology offers the possibility of zero mislabeled samples in the preanalytic stage.

  18. Automated batch fiducial-less tilt-series alignment in Appion using Protomo.

    PubMed

    Noble, Alex J; Stagg, Scott M

    2015-11-01

    The field of electron tomography has benefited greatly from manual and semi-automated approaches to marker-based tilt-series alignment that have allowed for the structural determination of multitudes of in situ cellular structures as well as macromolecular structures of individual protein complexes. The emergence of complementary metal-oxide semiconductor detectors capable of detecting individual electrons has enabled the collection of low dose, high contrast images, opening the door for reliable correlation-based tilt-series alignment. Here we present a set of automated, correlation-based tilt-series alignment, contrast transfer function (CTF) correction, and reconstruction workflows for use in conjunction with the Appion/Leginon package that are primarily targeted at automating structure determination with cryogenic electron microscopy. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Precision Departure Release Capability (PDRC) Overview and Results: NASA to FAA Research Transition

    NASA Technical Reports Server (NTRS)

    Engelland, Shawn; Davis, Tom.

    2013-01-01

    NASA researchers developed the Precision Departure Release Capability (PDRC) concept to improve the tactical departure scheduling process. The PDRC system is comprised of: 1) a surface automation system that computes ready time predictions and departure runway assignments, 2) an en route scheduling automation tool that uses this information to estimate ascent trajectories to the merge point and computes release times and, 3) an interface that provides two-way communication between the two systems. To minimize technology transfer issues and facilitate its adoption by TMCs and Frontline Managers (FLM), NASA developed the PDRC prototype using the Surface Decision Support System (SDSS) for the Tower surface automation tool, a research version of the FAA TMA (RTMA) for en route automation tool and a digital interface between the two DSTs to facilitate coordination.

  20. Utilization of BIM for automation of quantity takeoffs and cost estimation in transport infrastructure construction projects in the Czech Republic

    NASA Astrophysics Data System (ADS)

    Vitásek, Stanislav; Matějka, Petr

    2017-09-01

    The article deals with problematic parts of automated processing of quantity takeoff (QTO) from data generated in BIM model. It focuses on models of road constructions, and uses volumes and dimensions of excavation work to create an estimate of construction costs. The article uses a case study and explorative methods to discuss possibilities and problems of data transfer from a model to a price system of construction production when such transfer is used for price estimates of construction works. Current QTOs and price tenders are made with 2D documents. This process is becoming obsolete because more modern tools can be used. The BIM phenomenon enables partial automation in processing volumes and dimensions of construction units and matching the data to units in a given price scheme. Therefore price of construction can be estimated and structured without lengthy and often imprecise manual calculations. The use of BIM for QTO is highly dependent on local market budgeting systems, therefore proper push/pull strategy is required. It also requires proper requirements specification, compatible pricing database and software.

  1. The CADSS design automation system. [computerized design language for small digital systems

    NASA Technical Reports Server (NTRS)

    Franke, E. A.

    1973-01-01

    This research was designed to implement and extend a previously defined design automation system for the design of small digital structures. A description is included of the higher level language developed to describe systems as a sequence of register transfer operations. The system simulator which is used to determine if the original description is correct is also discussed. The design automation system produces tables describing the state transistions of the system and the operation of all registers. In addition all Boolean equations specifying system operation are minimized and converted to NAND gate structures. Suggestions for further extensions to the system are also given.

  2. Rhesus monkey (Macaca mulatta) complex learning skills reassessed

    NASA Technical Reports Server (NTRS)

    Washburn, David A.; Rumbaugh, Duane M.

    1991-01-01

    An automated computerized testing facility is employed to study basic learning and transfer in rhesus monkeys including discrimination learning set and mediational learning. The data show higher performance levels than those predicted from other tests that involved compromised learning with analogous conditions. Advanced transfer-index ratios and positive transfer of learning are identified, and indications of mediational learning strategies are noted. It is suggested that these data are evidence of the effectiveness of the present experimental apparatus for enhancing learning in nonhuman primates.

  3. Signal Delay-Stability of a Ku-Band Two-Way Satellite Time Transfer Terminal

    DTIC Science & Technology

    1995-12-01

    Robnik Space Research Institute, Graz, Austria Abstract A filly automated huo-way time and frequency transfer ( TWSTFT ) system including a sateme...station. Such a system has been operated for longer than a year together with the two-way satellite time and frequency transfer ( TWSTFT ) station of...accuracy. MEASUREMENT SETUP A detailed description of the TWSTFT system used at TUG is given in [I]. The SATSIM used is of the de Jong type13,41 - this

  4. ATV Ingress

    NASA Image and Video Library

    2014-08-13

    ISS040-E-091989 (13 Aug. 2014) --- European Space Agency astronaut Alexander Gerst, Expedition 40 flight engineer, enters the newly-attached "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5) of the International Space Station.

  5. Detection of Orbital Debris Collision Risks for the Automated Transfer Vehicle

    NASA Technical Reports Server (NTRS)

    Peret, L.; Legendre, P.; Delavault, S.; Martin, T.

    2007-01-01

    In this paper, we present a general collision risk assessment method, which has been applied through numerical simulations to the Automated Transfer Vehicle (ATV) case. During ATV ascent towards the International Space Station, close approaches between the ATV and objects of the USSTRACOM catalog will be monitored through collision rosk assessment. Usually, collision risk assessment relies on an exclusion volume or a probability threshold method. Probability methods are more effective than exclusion volumes but require accurate covariance data. In this work, we propose to use a criterion defined by an adaptive exclusion area. This criterion does not require any probability calculation but is more effective than exclusion volume methods as demonstrated by our numerical experiments. The results of these studies, when confirmed and finalized, will be used for the ATV operations.

  6. A high-throughput urinalysis of abused drugs based on a SPE-LC-MS/MS method coupled with an in-house developed post-analysis data treatment system.

    PubMed

    Cheng, Wing-Chi; Yau, Tsan-Sang; Wong, Ming-Kei; Chan, Lai-Ping; Mok, Vincent King-Kuen

    2006-10-16

    A rapid urinalysis system based on SPE-LC-MS/MS with an in-house post-analysis data management system has been developed for the simultaneous identification and semi-quantitation of opiates (morphine, codeine), methadone, amphetamines (amphetamine, methylamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA) and 3,4-methylenedioxymethamphetamine (MDMA)), 11-benzodiazepines or their metabolites and ketamine. The urine samples are subjected to automated solid phase extraction prior to analysis by LC-MS (Finnigan Surveyor LC connected to a Finnigan LCQ Advantage) fitted with an Alltech Rocket Platinum EPS C-18 column. With a single point calibration at the cut-off concentration for each analyte, simultaneous identification and semi-quantitation for the above mentioned drugs can be achieved in a 10 min run per urine sample. A computer macro-program package was developed to automatically retrieve appropriate data from the analytical data files, compare results with preset values (such as cut-off concentrations, MS matching scores) of each drug being analyzed and generate user-defined Excel reports to indicate all positive and negative results in batch-wise manner for ease of checking. The final analytical results are automatically copied into an Access database for report generation purposes. Through the use of automation in sample preparation, simultaneous identification and semi-quantitation by LC-MS/MS and a tailored made post-analysis data management system, this new urinalysis system significantly improves the quality of results, reduces the post-data treatment time, error due to data transfer and is suitable for high-throughput laboratory in batch-wise operation.

  7. Automated Sample Exchange Robots for the Structural Biology Beam Lines at the Photon Factory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hiraki, Masahiko; Watanabe, Shokei; Yamada, Yusuke

    2007-01-19

    We are now developing automated sample exchange robots for high-throughput protein crystallographic experiments for onsite use at synchrotron beam lines. It is part of the fully automated robotics systems being developed at the Photon Factory, for the purposes of protein crystallization, monitoring crystal growth, harvesting and freezing crystals, mounting the crystals inside a hutch and for data collection. We have already installed the sample exchange robots based on the SSRL automated mounting system at our insertion device beam lines BL-5A and AR-NW12A at the Photon Factory. In order to reduce the time required for sample exchange further, a prototype ofmore » a double-tonged system was developed. As a result of preliminary experiments with double-tonged robots, the sample exchange time was successfully reduced from 70 seconds to 10 seconds with the exception of the time required for pre-cooling and warming up the tongs.« less

  8. Fully Automated Sample Preparation for Ultrafast N-Glycosylation Analysis of Antibody Therapeutics.

    PubMed

    Szigeti, Marton; Lew, Clarence; Roby, Keith; Guttman, Andras

    2016-04-01

    There is a growing demand in the biopharmaceutical industry for high-throughput, large-scale N-glycosylation profiling of therapeutic antibodies in all phases of product development, but especially during clone selection when hundreds of samples should be analyzed in a short period of time to assure their glycosylation-based biological activity. Our group has recently developed a magnetic bead-based protocol for N-glycosylation analysis of glycoproteins to alleviate the hard-to-automate centrifugation and vacuum-centrifugation steps of the currently used protocols. Glycan release, fluorophore labeling, and cleanup were all optimized, resulting in a <4 h magnetic bead-based process with excellent yield and good repeatability. This article demonstrates the next level of this work by automating all steps of the optimized magnetic bead-based protocol from endoglycosidase digestion, through fluorophore labeling and cleanup with high-throughput sample processing in 96-well plate format, using an automated laboratory workstation. Capillary electrophoresis analysis of the fluorophore-labeled glycans was also optimized for rapid (<3 min) separation to accommodate the high-throughput processing of the automated sample preparation workflow. Ultrafast N-glycosylation analyses of several commercially relevant antibody therapeutics are also shown and compared to their biosimilar counterparts, addressing the biological significance of the differences. © 2015 Society for Laboratory Automation and Screening.

  9. Abbott prism: a multichannel heterogeneous chemiluminescence immunoassay analyzer.

    PubMed

    Khalil, O S; Zurek, T F; Tryba, J; Hanna, C F; Hollar, R; Pepe, C; Genger, K; Brentz, C; Murphy, B; Abunimeh, N

    1991-09-01

    We describe a multichannel heterogeneous immunoassay analyzer in which a sample is split between disposable reaction trays in a group of linear tracks. The system's pipettor uses noninvasive sensing of the sample volume and disposable pipet tips. Each assay track has (a) a conveyor belt for moving reaction trays to predetermined functional stations, (b) temperature-controlled tunnels, (c) noncontact transfer of the reaction mixture between incubation and detection wells, and (d) single-photon counting to detect a chemiluminescence (CL) signal from the captured immunochemical product. A novel disposable reaction tray, with separate reaction and detection wells and self-contained fluid removal, is used in conjunction with the transfer device on the track to produce a carryover-free system. The linear immunoassay track has nine predetermined positions for performing individual assay steps. Assay step sequence and timing is selected by changing the location of the assay modules between these predetermined positions. The assay methodology, a combination of microparticle capture and direct detection of a CL signal on a porous matrix, offers excellent sensitivity, specificity, and ease of automation. Immunoassay configurations have been tested for hepatitis B surface antigen and for antibodies to hepatitis B core antigen, hepatitis C virus, human immunodeficiency virus I and II, and human T-cell leukemia virus I and II.

  10. Evaluation of mouse red blood cell and platelet counting with an automated hematology analyzer.

    PubMed

    Fukuda, Teruko; Asou, Eri; Nogi, Kimiko; Goto, Kazuo

    2017-10-07

    An evaluation of mouse red blood cell (RBC) and platelet (PLT) counting with an automated hematology analyzer was performed with three strains of mice, C57BL/6 (B6), BALB/c (BALB) and DBA/2 (D2). There were no significant differences in RBC and PLT counts between manual and automated optical methods in any of the samples, except for D2 mice. For D2, RBC counts obtained using the manual method were significantly lower than those obtained using the automated optical method (P<0.05), and PLT counts obtained using the manual method were higher than those obtained using the automated optical method (P<0.05). An automated hematology analyzer can be used for RBC and PLT counting; however, an appropriate method should be selected when D2 mice samples are used.

  11. Examination of a high resolution laser optical plankton counter and FlowCAM for measuring plankton concentration and size

    NASA Astrophysics Data System (ADS)

    Kydd, Jocelyn; Rajakaruna, Harshana; Briski, Elizabeta; Bailey, Sarah

    2018-03-01

    Many commercial ships will soon begin to use treatment systems to manage their ballast water and reduce the global transfer of harmful aquatic organisms and pathogens in accordance with upcoming International Maritime Organization regulations. As a result, rapid and accurate automated methods will be needed to monitoring compliance of ships' ballast water. We examined two automated particle counters for monitoring organisms ≥ 50 μm in minimum dimension: a High Resolution Laser Optical Plankton Counter (HR-LOPC), and a Flow Cytometer with digital imaging Microscope (FlowCAM), in comparison to traditional (manual) microscopy considering plankton concentration, size frequency distributions and particle size measurements. The automated tools tended to underestimate particle concentration compared to standard microscopy, but gave similar results in terms of relative abundance of individual taxa. For most taxa, particle size measurements generated by FlowCAM ABD (Area Based Diameter) were more similar to microscope measurements than were those by FlowCAM ESD (Equivalent Spherical Diameter), though there was a mismatch in size estimates for some organisms between the FlowCAM ABD and microscope due to orientation and complex morphology. When a single problematic taxon is very abundant, the resulting size frequency distribution curves can become skewed, as was observed with Asterionella in this study. In particular, special consideration is needed when utilizing automated tools to analyse samples containing colonial species. Re-analysis of the size frequency distributions with the removal of Asterionella from FlowCAM and microscope data resulted in more similar curves across methods with FlowCAM ABD having the best fit compared to the microscope, although microscope concentration estimates were still significantly higher than estimates from the other methods. The results of our study indicate that both automated tools can generate frequency distributions of particles that might be particularly useful if correction factors can be developed for known differences in well-studied aquatic ecosystems.

  12. Kononenko floats through the ATV-3

    NASA Image and Video Library

    2012-04-06

    ISS030-E-210850 (6 April 2012) --- Russian cosmonaut Oleg Kononenko, Expedition 30 flight engineer, floats freely in the Automated Transfer Vehicle (ATV-3) currently docked with the International Space Station.

  13. Life Sciences Research Facility automation requirements and concepts for the Space Station

    NASA Technical Reports Server (NTRS)

    Rasmussen, Daryl N.

    1986-01-01

    An evaluation is made of the methods and preliminary results of a study on prospects for the automation of the NASA Space Station's Life Sciences Research Facility. In order to remain within current Space Station resource allocations, approximately 85 percent of planned life science experiment tasks must be automated; these tasks encompass specimen care and feeding, cage and instrument cleaning, data acquisition and control, sample analysis, waste management, instrument calibration, materials inventory and management, and janitorial work. Task automation will free crews for specimen manipulation, tissue sampling, data interpretation and communication with ground controllers, and experiment management.

  14. An automated gas exchange tank for determining gas transfer velocities in natural seawater samples

    NASA Astrophysics Data System (ADS)

    Schneider-Zapp, K.; Salter, M. E.; Upstill-Goddard, R. C.

    2014-07-01

    In order to advance understanding of the role of seawater surfactants in the air-sea exchange of climatically active trace gases via suppression of the gas transfer velocity (kw), we constructed a fully automated, closed air-water gas exchange tank and coupled analytical system. The system allows water-side turbulence in the tank to be precisely controlled with an electronically operated baffle. Two coupled gas chromatographs and an integral equilibrator, connected to the tank in a continuous gas-tight system, allow temporal changes in the partial pressures of SF6, CH4 and N2O to be measured simultaneously in the tank water and headspace at multiple turbulence settings, during a typical experimental run of 3.25 h. PC software developed by the authors controls all operations and data acquisition, enabling the optimisation of experimental conditions with high reproducibility. The use of three gases allows three independent estimates of kw for each turbulence setting; these values are subsequently normalised to a constant Schmidt number for direct comparison. The normalised kw estimates show close agreement. Repeated experiments with Milli-Q water demonstrate a typical measurement accuracy of 4% for kw. Experiments with natural seawater show that the system clearly resolves the effects on kw of spatial and temporal trends in natural surfactant activity. The system is an effective tool with which to probe the relationships between kw, surfactant activity and biogeochemical indices of primary productivity, and should assist in providing valuable new insights into the air-sea gas exchange process.

  15. An automated gas exchange tank for determining gas transfer velocities in natural seawater samples

    NASA Astrophysics Data System (ADS)

    Schneider-Zapp, K.; Salter, M. E.; Upstill-Goddard, R. C.

    2014-02-01

    In order to advance understanding of the role of seawater surfactants in the air-sea exchange of climatically active trace gases via suppression of the gas transfer velocity (kw), we constructed a fully automated, closed air-water gas exchange tank and coupled analytical system. The system allows water-side turbulence in the tank to be precisely controlled with an electronically operated baffle. Two coupled gas chromatographs and an integral equilibrator, connected to the tank in a continuous gas-tight system, allow temporal changes in the partial pressures of SF6, CH4 and N2O to be measured simultaneously in the tank water and headspace at multiple turbulence settings, during a typical experimental run of 3.25 h. PC software developed by the authors controls all operations and data acquisition, enabling the optimisation of experimental conditions with high reproducibility. The use of three gases allows three independent estimates of kw for each turbulence setting; these values are subsequently normalised to a constant Schmidt number for direct comparison. The normalised kw estimates show close agreement. Repeated experiments with MilliQ water demonstrate a typical measurement accuracy of 4% for kw. Experiments with natural seawater show that the system clearly resolves the effects on kw of spatial and temporal trends in natural surfactant activity. The system is an effective tool with which to probe the relationships between kw, surfactant activity and biogeochemical indices of primary productivity, and should assist in providing valuable new insights into the air-sea gas exchange process.

  16. Telecommunications Protocol Processing Subsystem Using Reconfigurable Interoperable Gate Arrays

    NASA Technical Reports Server (NTRS)

    Pang, Jackson; Pingree, Paula; Torgerson, J. Leigh

    2006-01-01

    Deep Space Telecommunications Requirements: 1) Automated file transfer across inter-planetary distances; 2) Limited communication periods; 3) Reliable transport; 4) Delay and Disruption Tolerant; and 5) Asymmetric Data Channels.

  17. Kuipers floats through the ATV-3

    NASA Image and Video Library

    2012-04-06

    ISS030-E-210842 (6 April 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, floats into the Automated Transfer Vehicle (ATV-3) currently docked with the International Space Station.

  18. ATV Ingress

    NASA Image and Video Library

    2014-08-13

    ISS040-E-091966 (13 Aug. 2014) --- European Space Agency astronaut Alexander Gerst, Expedition 40 flight engineer, is pictured in the newly-attached "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5) of the International Space Station.

  19. Kuipers works in the ATV-3

    NASA Image and Video Library

    2012-04-06

    ISS030-E-210896 (6 April 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, works in the Automated Transfer Vehicle (ATV-3) currently docked with the International Space Station.

  20. Automation in clinical bacteriology: what system to choose?

    PubMed

    Greub, G; Prod'hom, G

    2011-05-01

    With increased activity and reduced financial and human resources, there is a need for automation in clinical bacteriology. Initial processing of clinical samples includes repetitive and fastidious steps. These tasks are suitable for automation, and several instruments are now available on the market, including the WASP (Copan), Previ-Isola (BioMerieux), Innova (Becton-Dickinson) and Inoqula (KIESTRA) systems. These new instruments allow efficient and accurate inoculation of samples, including four main steps: (i) selecting the appropriate Petri dish; (ii) inoculating the sample; (iii) spreading the inoculum on agar plates to obtain, upon incubation, well-separated bacterial colonies; and (iv) accurate labelling and sorting of each inoculated media. The challenge for clinical bacteriologists is to determine what is the ideal automated system for their own laboratory. Indeed, different solutions will be preferred, according to the number and variety of samples, and to the types of sample that will be processed with the automated system. The final choice is troublesome, because audits proposed by industrials risk being biased towards the solution proposed by their company, and because these automated systems may not be easily tested on site prior to the final decision, owing to the complexity of computer connections between the laboratory information system and the instrument. This article thus summarizes the main parameters that need to be taken into account for choosing the optimal system, and provides some clues to help clinical bacteriologists to make their choice. © 2011 The Authors. Clinical Microbiology and Infection © 2011 European Society of Clinical Microbiology and Infectious Diseases.

  1. The RABiT: a rapid automated biodosimetry tool for radiological triage. II. Technological developments.

    PubMed

    Garty, Guy; Chen, Youhua; Turner, Helen C; Zhang, Jian; Lyulko, Oleksandra V; Bertucci, Antonella; Xu, Yanping; Wang, Hongliang; Simaan, Nabil; Randers-Pehrson, Gerhard; Lawrence Yao, Y; Brenner, David J

    2011-08-01

    Over the past five years the Center for Minimally Invasive Radiation Biodosimetry at Columbia University has developed the Rapid Automated Biodosimetry Tool (RABiT), a completely automated, ultra-high throughput biodosimetry workstation. This paper describes recent upgrades and reliability testing of the RABiT. The RABiT analyses fingerstick-derived blood samples to estimate past radiation exposure or to identify individuals exposed above or below a cut-off dose. Through automated robotics, lymphocytes are extracted from fingerstick blood samples into filter-bottomed multi-well plates. Depending on the time since exposure, the RABiT scores either micronuclei or phosphorylation of the histone H2AX, in an automated robotic system, using filter-bottomed multi-well plates. Following lymphocyte culturing, fixation and staining, the filter bottoms are removed from the multi-well plates and sealed prior to automated high-speed imaging. Image analysis is performed online using dedicated image processing hardware. Both the sealed filters and the images are archived. We have developed a new robotic system for lymphocyte processing, making use of an upgraded laser power and parallel processing of four capillaries at once. This system has allowed acceleration of lymphocyte isolation, the main bottleneck of the RABiT operation, from 12 to 2 sec/sample. Reliability tests have been performed on all robotic subsystems. Parallel handling of multiple samples through the use of dedicated, purpose-built, robotics and high speed imaging allows analysis of up to 30,000 samples per day.

  2. The RABiT: A Rapid Automated Biodosimetry Tool For Radiological Triage. II. Technological Developments

    PubMed Central

    Garty, Guy; Chen, Youhua; Turner, Helen; Zhang, Jian; Lyulko, Oleksandra; Bertucci, Antonella; Xu, Yanping; Wang, Hongliang; Simaan, Nabil; Randers-Pehrson, Gerhard; Yao, Y. Lawrence; Brenner, David J.

    2011-01-01

    Purpose Over the past five years the Center for Minimally Invasive Radiation Biodosimetry at Columbia University has developed the Rapid Automated Biodosimetry Tool (RABiT), a completely automated, ultra-high throughput biodosimetry workstation. This paper describes recent upgrades and reliability testing of the RABiT. Materials and methods The RABiT analyzes fingerstick-derived blood samples to estimate past radiation exposure or to identify individuals exposed above or below a cutoff dose. Through automated robotics, lymphocytes are extracted from fingerstick blood samples into filter-bottomed multi-well plates. Depending on the time since exposure, the RABiT scores either micronuclei or phosphorylation of the histone H2AX, in an automated robotic system, using filter-bottomed multi-well plates. Following lymphocyte culturing, fixation and staining, the filter bottoms are removed from the multi-well plates and sealed prior to automated high-speed imaging. Image analysis is performed online using dedicated image processing hardware. Both the sealed filters and the images are archived. Results We have developed a new robotic system for lymphocyte processing, making use of an upgraded laser power and parallel processing of four capillaries at once. This system has allowed acceleration of lymphocyte isolation, the main bottleneck of the RABiT operation, from 12 to 2 sec/sample. Reliability tests have been performed on all robotic subsystems. Conclusions Parallel handling of multiple samples through the use of dedicated, purpose-built, robotics and high speed imaging allows analysis of up to 30,000 samples per day. PMID:21557703

  3. A Computational Approach for Automated Posturing of a Human Finite Element Model

    DTIC Science & Technology

    2016-07-01

    Std. Z39.18 July 2016 Memorandum Report A Computational Approach for Automated Posturing of a Human Finite Element Model Justin McKee and Adam...protection by influencing the path that loading will be transferred into the body and is a major source of variability. The development of a finite element ...posture, human body, finite element , leg, spine 42 Adam Sokolow 410-306-2985Unclassified Unclassified Unclassified UU ii Approved for public release

  4. Earth Observations taken by Expedition 41 crewmember

    NASA Image and Video Library

    2014-09-13

    ISS041-E-013683 (13 Sept. 2014) --- Photographed with a mounted automated camera, this is one of a number of images featuring the European Space Agency?s Automated Transfer Vehicle (ATV-5 or Georges Lemaitre) docked with the International Space Station. Except for color changes, the images are almost identical. The variation in color from frame to frame is due to the camera?s response to the motion of the orbital outpost, relative to the illumination from the sun.

  5. Earth Observations taken by Expedition 41 crewmember

    NASA Image and Video Library

    2014-09-13

    ISS041-E-013687 (13 Sept. 2014) --- Photographed with a mounted automated camera, this is one of a number of images featuring the European Space Agency?s Automated Transfer Vehicle (ATV-5 or Georges Lemaitre) docked with the International Space Station. Except for color changes, the images are almost identical. The variation in color from frame to frame is due to the camera?s response to the motion of the orbital outpost, relative to the illumination from the sun.

  6. Earth Observations taken by Expedition 41 crewmember

    NASA Image and Video Library

    2014-09-13

    ISS041-E-013693 (13 Sept. 2014) --- Photographed with a mounted automated camera, this is one of a number of images featuring the European Space Agency?s Automated Transfer Vehicle (ATV-5 or Georges Lemaitre) docked with the International Space Station. Except for color changes, the images are almost identical. The variation in color from frame to frame is due to the camera?s response to the motion of the orbital outpost, relative to the illumination from the sun.

  7. Gas pressure assisted microliquid-liquid extraction coupled online to direct infusion mass spectrometry: a new automated screening platform for bioanalysis.

    PubMed

    Raterink, Robert-Jan; Witkam, Yoeri; Vreeken, Rob J; Ramautar, Rawi; Hankemeier, Thomas

    2014-10-21

    In the field of bioanalysis, there is an increasing demand for miniaturized, automated, robust sample pretreatment procedures that can be easily connected to direct-infusion mass spectrometry (DI-MS) in order to allow the high-throughput screening of drugs and/or their metabolites in complex body fluids like plasma. Liquid-Liquid extraction (LLE) is a common sample pretreatment technique often used for complex aqueous samples in bioanalysis. Despite significant developments that have been made in automated and miniaturized LLE procedures, fully automated LLE techniques allowing high-throughput bioanalytical studies on small-volume samples using direct infusion mass spectrometry, have not been matured yet. Here, we introduce a new fully automated micro-LLE technique based on gas-pressure assisted mixing followed by passive phase separation, coupled online to nanoelectrospray-DI-MS. Our method was characterized by varying the gas flow and its duration through the solvent mixture. For evaluation of the analytical performance, four drugs were spiked to human plasma, resulting in highly acceptable precision (RSD down to 9%) and linearity (R(2) ranging from 0.990 to 0.998). We demonstrate that our new method does not only allow the reliable extraction of analytes from small sample volumes of a few microliters in an automated and high-throughput manner, but also performs comparable or better than conventional offline LLE, in which the handling of small volumes remains challenging. Finally, we demonstrate the applicability of our method for drug screening on dried blood spots showing excellent linearity (R(2) of 0.998) and precision (RSD of 9%). In conclusion, we present the proof of principe of a new high-throughput screening platform for bioanalysis based on a new automated microLLE method, coupled online to a commercially available nano-ESI-DI-MS.

  8. Automated indirect immunofluorescence evaluation of antinuclear autoantibodies on HEp-2 cells.

    PubMed

    Voigt, Jörn; Krause, Christopher; Rohwäder, Edda; Saschenbrecker, Sandra; Hahn, Melanie; Danckwardt, Maick; Feirer, Christian; Ens, Konstantin; Fechner, Kai; Barth, Erhardt; Martinetz, Thomas; Stöcker, Winfried

    2012-01-01

    Indirect immunofluorescence (IIF) on human epithelial (HEp-2) cells is considered as the gold standard screening method for the detection of antinuclear autoantibodies (ANA). However, in terms of automation and standardization, it has not been able to keep pace with most other analytical techniques used in diagnostic laboratories. Although there are already some automation solutions for IIF incubation in the market, the automation of result evaluation is still in its infancy. Therefore, the EUROPattern Suite has been developed as a comprehensive automated processing and interpretation system for standardized and efficient ANA detection by HEp-2 cell-based IIF. In this study, the automated pattern recognition was compared to conventional visual interpretation in a total of 351 sera. In the discrimination of positive from negative samples, concordant results between visual and automated evaluation were obtained for 349 sera (99.4%, kappa = 0.984). The system missed out none of the 272 antibody-positive samples and identified 77 out of 79 visually negative samples (analytical sensitivity/specificity: 100%/97.5%). Moreover, 94.0% of all main antibody patterns were recognized correctly by the software. Owing to its performance characteristics, EUROPattern enables fast, objective, and economic IIF ANA analysis and has the potential to reduce intra- and interlaboratory variability.

  9. Automated Indirect Immunofluorescence Evaluation of Antinuclear Autoantibodies on HEp-2 Cells

    PubMed Central

    Voigt, Jörn; Krause, Christopher; Rohwäder, Edda; Saschenbrecker, Sandra; Hahn, Melanie; Danckwardt, Maick; Feirer, Christian; Ens, Konstantin; Fechner, Kai; Barth, Erhardt; Martinetz, Thomas; Stöcker, Winfried

    2012-01-01

    Indirect immunofluorescence (IIF) on human epithelial (HEp-2) cells is considered as the gold standard screening method for the detection of antinuclear autoantibodies (ANA). However, in terms of automation and standardization, it has not been able to keep pace with most other analytical techniques used in diagnostic laboratories. Although there are already some automation solutions for IIF incubation in the market, the automation of result evaluation is still in its infancy. Therefore, the EUROPattern Suite has been developed as a comprehensive automated processing and interpretation system for standardized and efficient ANA detection by HEp-2 cell-based IIF. In this study, the automated pattern recognition was compared to conventional visual interpretation in a total of 351 sera. In the discrimination of positive from negative samples, concordant results between visual and automated evaluation were obtained for 349 sera (99.4%, kappa = 0.984). The system missed out none of the 272 antibody-positive samples and identified 77 out of 79 visually negative samples (analytical sensitivity/specificity: 100%/97.5%). Moreover, 94.0% of all main antibody patterns were recognized correctly by the software. Owing to its performance characteristics, EUROPattern enables fast, objective, and economic IIF ANA analysis and has the potential to reduce intra- and interlaboratory variability. PMID:23251220

  10. Feasibility of automated speech sample collection with stuttering children using interactive voice response (IVR) technology.

    PubMed

    Vogel, Adam P; Block, Susan; Kefalianos, Elaina; Onslow, Mark; Eadie, Patricia; Barth, Ben; Conway, Laura; Mundt, James C; Reilly, Sheena

    2015-04-01

    To investigate the feasibility of adopting automated interactive voice response (IVR) technology for remotely capturing standardized speech samples from stuttering children. Participants were 10 6-year-old stuttering children. Their parents called a toll-free number from their homes and were prompted to elicit speech from their children using a standard protocol involving conversation, picture description and games. The automated IVR system was implemented using an off-the-shelf telephony software program and delivered by a standard desktop computer. The software infrastructure utilizes voice over internet protocol. Speech samples were automatically recorded during the calls. Video recordings were simultaneously acquired in the home at the time of the call to evaluate the fidelity of the telephone collected samples. Key outcome measures included syllables spoken, percentage of syllables stuttered and an overall rating of stuttering severity using a 10-point scale. Data revealed a high level of relative reliability in terms of intra-class correlation between the video and telephone acquired samples on all outcome measures during the conversation task. Findings were less consistent for speech samples during picture description and games. Results suggest that IVR technology can be used successfully to automate remote capture of child speech samples.

  11. Campylobacter in Broiler Chicken and Broiler Meat in Sri Lanka: Influence of Semi-Automated vs. Wet Market Processing on Campylobacter Contamination of Broiler Neck Skin Samples.

    PubMed

    Kottawatta, Kottawattage S A; Van Bergen, Marcel A P; Abeynayake, Preeni; Wagenaar, Jaap A; Veldman, Kees T; Kalupahana, Ruwani S

    2017-11-29

    Broiler meat can become contaminated with Campylobacter of intestinal origin during processing. The present study aimed to identify the prevalence of Campylobacter in broiler flocks and meat contamination at retail shops, and determine the influence of semi-automated and wet market processing on Campylobacter contamination of neck skin samples. Samples were collected from semi-automated plants ( n = 102) and wet markets ( n = 25). From each batch of broilers, pooled caecal samples and neck skin samples were tested for Campylobacter . Broiler meat purchased from retail outlets ( n = 37) was also tested. The prevalence of Campylobacter colonized broiler flocks was 67%. The contamination of meat at retail was 59%. Both semi-automated and wet market processing resulted to contaminate the broiler neck skins to the levels of 27.4% and 48%, respectively. When Campylobacter -free broiler flocks were processed in semi-automated facilities 15% (5/33) of neck skin samples became contaminated by the end of processing whereas 25% (2/8) became contaminated after wet market processing. Characterization of isolates revealed a higher proportion of C. coli compared to C. jejuni . Higher proportions of isolates were resistant to important antimicrobials. This study shows the importance of Campylobacter in poultry industry in Sri Lanka and the need for controlling antimicrobial resistance.

  12. Campylobacter in Broiler Chicken and Broiler Meat in Sri Lanka: Influence of Semi-Automated vs. Wet Market Processing on Campylobacter Contamination of Broiler Neck Skin Samples

    PubMed Central

    Kottawatta, Kottawattage S. A.; Van Bergen, Marcel A. P.; Abeynayake, Preeni; Wagenaar, Jaap A.; Veldman, Kees T.; Kalupahana, Ruwani S.

    2017-01-01

    Broiler meat can become contaminated with Campylobacter of intestinal origin during processing. The present study aimed to identify the prevalence of Campylobacter in broiler flocks and meat contamination at retail shops, and determine the influence of semi-automated and wet market processing on Campylobacter contamination of neck skin samples. Samples were collected from semi-automated plants (n = 102) and wet markets (n = 25). From each batch of broilers, pooled caecal samples and neck skin samples were tested for Campylobacter. Broiler meat purchased from retail outlets (n = 37) was also tested. The prevalence of Campylobacter colonized broiler flocks was 67%. The contamination of meat at retail was 59%. Both semi-automated and wet market processing resulted to contaminate the broiler neck skins to the levels of 27.4% and 48%, respectively. When Campylobacter-free broiler flocks were processed in semi-automated facilities 15% (5/33) of neck skin samples became contaminated by the end of processing whereas 25% (2/8) became contaminated after wet market processing. Characterization of isolates revealed a higher proportion of C. coli compared to C. jejuni. Higher proportions of isolates were resistant to important antimicrobials. This study shows the importance of Campylobacter in poultry industry in Sri Lanka and the need for controlling antimicrobial resistance. PMID:29186018

  13. Integrated Multi-process Microfluidic Systems for Automating Analysis

    PubMed Central

    Yang, Weichun; Woolley, Adam T.

    2010-01-01

    Microfluidic technologies have been applied extensively in rapid sample analysis. Some current challenges for standard microfluidic systems are relatively high detection limits, and reduced resolving power and peak capacity compared to conventional approaches. The integration of multiple functions and components onto a single platform can overcome these separation and detection limitations of microfluidics. Multiplexed systems can greatly increase peak capacity in multidimensional separations and can increase sample throughput by analyzing many samples simultaneously. On-chip sample preparation, including labeling, preconcentration, cleanup and amplification, can all serve to speed up and automate processes in integrated microfluidic systems. This paper summarizes advances in integrated multi-process microfluidic systems for automated analysis, their benefits and areas for needed improvement. PMID:20514343

  14. Current status and future prospects of an automated sample exchange system PAM for protein crystallography

    NASA Astrophysics Data System (ADS)

    Hiraki, M.; Yamada, Y.; Chavas, L. M. G.; Matsugaki, N.; Igarashi, N.; Wakatsuki, S.

    2013-03-01

    To achieve fully-automated and/or remote data collection in high-throughput X-ray experiments, the Structural Biology Research Centre at the Photon Factory (PF) has installed PF automated mounting system (PAM) for sample exchange robots at PF macromolecular crystallography beamlines BL-1A, BL-5A, BL-17A, AR-NW12A and AR-NE3A. We are upgrading the experimental systems, including the PAM for stable and efficient operation. To prevent human error in automated data collection, we installed a two-dimensional barcode reader for identification of the cassettes and sample pins. Because no liquid nitrogen pipeline in the PF experimental hutch is installed, the users commonly add liquid nitrogen using a small Dewar. To address this issue, an automated liquid nitrogen filling system that links a 100-liter tank to the robot Dewar has been installed on the PF macromolecular beamline. Here we describe this new implementation, as well as future prospects.

  15. ROBOCAL: An automated NDA (nondestructive analysis) calorimetry and gamma isotopic system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hurd, J.R.; Powell, W.D.; Ostenak, C.A.

    1989-11-01

    ROBOCAL, which is presently being developed and tested at Los Alamos National Laboratory, is a full-scale, prototype robotic system for remote calorimetric and gamma-ray analysis of special nuclear materials. It integrates a fully automated, multidrawer, vertical stacker-retriever system for staging unmeasured nuclear materials, and a fully automated gantry robot for computer-based selection and transfer of nuclear materials to calorimetric and gamma-ray measurement stations. Since ROBOCAL is designed for minimal operator intervention, a completely programmed user interface is provided to interact with the automated mechanical and assay systems. The assay system is designed to completely integrate calorimetric and gamma-ray data acquisitionmore » and to perform state-of-the-art analyses on both homogeneous and heterogeneous distributions of nuclear materials in a wide variety of matrices.« less

  16. Oxygen-controlled automated neural differentiation of mouse embryonic stem cells.

    PubMed

    Mondragon-Teran, Paul; Tostoes, Rui; Mason, Chris; Lye, Gary J; Veraitch, Farlan S

    2013-03-01

    Automation and oxygen tension control are two tools that provide significant improvements to the reproducibility and efficiency of stem cell production processes. the aim of this study was to establish a novel automation platform capable of controlling oxygen tension during both the cell-culture and liquid-handling steps of neural differentiation processes. We built a bespoke automation platform, which enclosed a liquid-handling platform in a sterile, oxygen-controlled environment. An airtight connection was used to transfer cell culture plates to and from an automated oxygen-controlled incubator. Our results demonstrate that our system yielded comparable cell numbers, viabilities, metabolism profiles and differentiation efficiencies when compared with traditional manual processes. Interestingly, eliminating exposure to ambient conditions during the liquid-handling stage resulted in significant improvements in the yield of MAP2-positive neural cells, indicating that this level of control can improve differentiation processes. This article describes, for the first time, an automation platform capable of maintaining oxygen tension control during both the cell-culture and liquid-handling stages of a 2D embryonic stem cell differentiation process.

  17. Application of the H-Mode, a Design and Interaction Concept for Highly Automated Vehicles, to Aircraft

    NASA Technical Reports Server (NTRS)

    Goodrich, Kenneth H.; Flemisch, Frank O.; Schutte, Paul C.; Williams, Ralph A.

    2006-01-01

    Driven by increased safety, efficiency, and airspace capacity, automation is playing an increasing role in aircraft operations. As aircraft become increasingly able to autonomously respond to a range of situations with performance surpassing human operators, we are compelled to look for new methods that help us understand their use and guide their design using new forms of automation and interaction. We propose a novel design metaphor to aid the conceptualization, design, and operation of highly-automated aircraft. Design metaphors transfer meaning from common experiences to less familiar applications or functions. A notable example is the "Desktop metaphor" for manipulating files on a computer. This paper describes a metaphor for highly automated vehicles known as the H-metaphor and a specific embodiment of the metaphor known as the H-mode as applied to aircraft. The fundamentals of the H-metaphor are reviewed followed by an overview of an exploratory usability study investigating human-automation interaction issues for a simple H-mode implementation. The envisioned application of the H-mode concept to aircraft is then described as are two planned evaluations.

  18. Honeywell Technical Order Transfer Tests.

    DTIC Science & Technology

    1987-06-12

    of simple corrections, a reasonable reproduction of the original could be generated. The quality was not good enough for a production environment. Lack of automated quality control (AQC) tools could account for the errors.

  19. Plasma cortisol and noradrenalin concentrations in pigs: automated sampling of freely moving pigs housed in PigTurn versus manually sampled and restrained pigs

    USDA-ARS?s Scientific Manuscript database

    Minimizing the effects of restraint and human interaction on the endocrine physiology of animals is essential for collection of accurate physiological measurements. Our objective was to compare stress-induced cortisol (CORT) and noradrenalin (NorA) responses in automated versus manual blood sampling...

  20. Preface to the special section on human factors and automation in vehicles: designing highly automated vehicles with the driver in mind.

    PubMed

    Merat, Natasha; Lee, John D

    2012-10-01

    This special section brings together diverse research regarding driver interaction with advanced automotive technology to guide design of increasingly automated vehicles. Rapidly evolving vehicle automation will likely change cars and trucks more in the next 5 years than the preceding 50, radically redefining what it means to drive. This special section includes 10 articles from European and North American researchers reporting simulator and naturalistic driving studies. Little research has considered the consequences of fully automated driving, with most focusing on lane-keeping and speed control systems individually. The studies reveal two underlying design philosophies: automate driving versus support driving. Results of several studies, consistent with previous research in other domains, suggest that the automate philosophy can delay driver responses to incidents in which the driver has to intervene and take control from the automation. Understanding how to orchestrate the transfer or sharing of control between the system and the driver, particularly in critical incidents, emerges as a central challenge. Designers should not assume that automation can substitute seamlessly for a human driver, nor can they assume that the driver can safely accommodate the limitations of automation. Designers, policy makers, and researchers must give careful consideration to what role the person should have in highly automated vehicles and how to support the driver if the driver is to be responsible for vehicle control. As in other domains, driving safety increasingly depends on the combined performance of the human and automation, and successful designs will depend on recognizing and supporting the new roles of the driver.

  1. ATV Ingress

    NASA Image and Video Library

    2014-08-13

    ISS040-E-091940 (13 Aug. 2014) --- Russian cosmonaut Alexander Skvortsov, Expedition 40 flight engineer, prepares to remove the docking mechanism to gain access to the hatch of the newly attached "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5).

  2. Kuipers in ATV3

    NASA Image and Video Library

    2012-05-15

    ISS031-E-157790 (15 May 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 31 flight engineer, floats freely in ESA?s "Edoardo Amaldi" Automated Transfer Vehicle-3 (ATV-3) currently docked with the International Space Station.

  3. Design and Testing of an Automated System using Thermochromatic Liquid Crystals to Determine Local Heat Transfer Coefficients for an Impinging Jet

    NASA Technical Reports Server (NTRS)

    Tan, Benjamin

    1995-01-01

    Using thermochromatic liquid crystal to measure surface temperature, an automated transient method with time-varying free-stream temperature is developed to determine local heat transfer coefficients. By allowing the free-stream temperature to vary with time, the need for complicated mechanical components to achieve a step temperature change is eliminated, and by using the thermochromatic liquid crystals as temperature indicators, the labor intensive task of installing many thermocouples is omitted. Bias associated with human perception of the transition of the thermochromatic liquid crystal is eliminated by using a high speed digital camera and a computer. The method is validated by comparisons with results obtained by the steady-state method for a circular Jet impinging on a flat plate. Several factors affecting the accuracy of the method are evaluated.

  4. SMIF capability at Intel Mask Operation improves yield

    NASA Astrophysics Data System (ADS)

    Dam, Thuc H.; Pekny, Matt; Millino, Jim; Luu, Gibson; Melwani, Nitesh; Venkatramani, Aparna; Tavassoli, Malahat

    2003-08-01

    At Intel Mask Operations (IMO), Standard Mechanical Interface (SMIF) processing has been employed to reduce environmental particle contamination from manual handling-related activities. SMIF handling entailed the utilization of automated robotic transfers of photoblanks/reticles between SMIF pods, whereas conventional handling utilized manual pick transfers of masks between SMIF pods with intermediate storage in Toppan compacts. The SMIF-enabling units in IMO's process line included: (1) coater, (2) exposure, (3) developer, (4) dry etcher, and (5) inspection. Each unit is equipped with automated I/O port, environmentally enclosed processing chamber, and SMIF pods. Yield metrics were utilized to demonstrate the effectiveness and advantages of SMIF processing compared to manual processing. The areas focused in this paper were blank resist coating, binary front-end reticle processing and 2nd level PSM reticle processing. Results obtained from the investigation showed yield improvements in these areas.

  5. Hyphenated and comprehensive liquid chromatography × gas chromatography-mass spectrometry for the identification of Mycobacterium tuberculosis.

    PubMed

    Mourão, Marta P B; Denekamp, Ilse; Kuijper, Sjoukje; Kolk, Arend H J; Janssen, Hans-Gerd

    2016-03-25

    Tuberculosis is one of the world's most emerging public health problems, particularly in developing countries. Chromatography based methods have been used to tackle this epidemic by focusing on biomarker detection. Unfortunately, interferences from lipids in the sputum matrix, particularly cholesterol, adversely affect the identification and detection of the marker compounds. The present contribution describes the serial combination of normal phase liquid chromatography (NPLC) with thermally assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) to overcome the difficulties of biomarker evaluation. The in-series combination consists of an LC analysis where fractions are collected and then transferred to the THM-GC-MS system. This was either done with comprehensive coupling, transferring all the fractions, or with hyphenated interfacing, i.e. off-line multi heart-cutting, transferring only selected fractions. Owing to the high sensitivity and selectivity of LC as a sample pre-treatment method, and to the high specificity of the MS as a detector, this analytical approach, NPLC × THM-GC-MS, is extremely sensitive. The results obtained indicate that this analytical set-up is able to detect down to 1 × 10(3) mycobacteria/mL of Mycobacterium tuberculosis strain 124, spiked in blank sputum samples. It is a powerful analytical tool and also has great potential for full automation. If further studies demonstrate its usefulness when applied blind in real sputum specimens, this technique could compete with the current smear microscopy in the early diagnosis of tuberculosis. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Potential of Laboratory Execution Systems (LESs) to Simplify the Application of Business Process Management Systems (BPMSs) in Laboratory Automation.

    PubMed

    Neubert, Sebastian; Göde, Bernd; Gu, Xiangyu; Stoll, Norbert; Thurow, Kerstin

    2017-04-01

    Modern business process management (BPM) is increasingly interesting for laboratory automation. End-to-end workflow automation and improved top-level systems integration for information technology (IT) and automation systems are especially prominent objectives. With the ISO Standard Business Process Model and Notation (BPMN) 2.X, a system-independent and interdisciplinary accepted graphical process control notation is provided, allowing process analysis, while also being executable. The transfer of BPM solutions to structured laboratory automation places novel demands, for example, concerning the real-time-critical process and systems integration. The article discusses the potential of laboratory execution systems (LESs) for an easier implementation of the business process management system (BPMS) in hierarchical laboratory automation. In particular, complex application scenarios, including long process chains based on, for example, several distributed automation islands and mobile laboratory robots for a material transport, are difficult to handle in BPMSs. The presented approach deals with the displacement of workflow control tasks into life science specialized LESs, the reduction of numerous different interfaces between BPMSs and subsystems, and the simplification of complex process modelings. Thus, the integration effort for complex laboratory workflows can be significantly reduced for strictly structured automation solutions. An example application, consisting of a mixture of manual and automated subprocesses, is demonstrated by the presented BPMS-LES approach.

  7. Virtual automation.

    PubMed

    Casis, E; Garrido, A; Uranga, B; Vives, A; Zufiaurre, C

    2001-01-01

    Total laboratory automation (TLA) can be substituted in mid-size laboratories by a computer sample workflow control (virtual automation). Such a solution has been implemented in our laboratory using PSM, software developed in cooperation with Roche Diagnostics (Barcelona, Spain), to this purpose. This software is connected to the online analyzers and to the laboratory information system and is able to control and direct the samples working as an intermediate station. The only difference with TLA is the replacement of transport belts by personnel of the laboratory. The implementation of this virtual automation system has allowed us the achievement of the main advantages of TLA: workload increase (64%) with reduction in the cost per test (43%), significant reduction in the number of biochemistry primary tubes (from 8 to 2), less aliquoting (from 600 to 100 samples/day), automation of functional testing, drastic reduction of preanalytical errors (from 11.7 to 0.4% of the tubes) and better total response time for both inpatients (from up to 48 hours to up to 4 hours) and outpatients (from up to 10 days to up to 48 hours). As an additional advantage, virtual automation could be implemented without hardware investment and significant headcount reduction (15% in our lab).

  8. Automated Fast Screening Method for Cocaine Identification in Seized Drug Samples Using a Portable Fourier Transform Infrared (FT-IR) Instrument.

    PubMed

    Mainali, Dipak; Seelenbinder, John

    2016-05-01

    Quick and presumptive identification of seized drug samples without destroying evidence is necessary for law enforcement officials to control the trafficking and abuse of drugs. This work reports an automated screening method to detect the presence of cocaine in seized samples using portable Fourier transform infrared (FT-IR) spectrometers. The method is based on the identification of well-defined characteristic vibrational frequencies related to the functional group of the cocaine molecule and is fully automated through the use of an expert system. Traditionally, analysts look for key functional group bands in the infrared spectra and characterization of the molecules present is dependent on user interpretation. This implies the need for user expertise, especially in samples that likely are mixtures. As such, this approach is biased and also not suitable for non-experts. The method proposed in this work uses the well-established "center of gravity" peak picking mathematical algorithm and combines it with the conditional reporting feature in MicroLab software to provide an automated method that can be successfully employed by users with varied experience levels. The method reports the confidence level of cocaine present only when a certain number of cocaine related peaks are identified by the automated method. Unlike library search and chemometric methods that are dependent on the library database or the training set samples used to build the calibration model, the proposed method is relatively independent of adulterants and diluents present in the seized mixture. This automated method in combination with a portable FT-IR spectrometer provides law enforcement officials, criminal investigators, or forensic experts a quick field-based prescreening capability for the presence of cocaine in seized drug samples. © The Author(s) 2016.

  9. Protein purification and analysis: next generation Western blotting techniques.

    PubMed

    Mishra, Manish; Tiwari, Shuchita; Gomes, Aldrin V

    2017-11-01

    Western blotting is one of the most commonly used techniques in molecular biology and proteomics. Since western blotting is a multistep protocol, variations and errors can occur at any step reducing the reliability and reproducibility of this technique. Recent reports suggest that a few key steps, such as the sample preparation method, the amount and source of primary antibody used, as well as the normalization method utilized, are critical for reproducible western blot results. Areas covered: In this review, improvements in different areas of western blotting, including protein transfer and antibody validation, are summarized. The review discusses the most advanced western blotting techniques available and highlights the relationship between next generation western blotting techniques and its clinical relevance. Expert commentary: Over the last decade significant improvements have been made in creating more sensitive, automated, and advanced techniques by optimizing various aspects of the western blot protocol. New methods such as single cell-resolution western blot, capillary electrophoresis, DigiWest, automated microfluid western blotting and microchip electrophoresis have all been developed to reduce potential problems associated with the western blotting technique. Innovative developments in instrumentation and increased sensitivity for western blots offer novel possibilities for increasing the clinical implications of western blot.

  10. RoboOligo: software for mass spectrometry data to support manual and de novo sequencing of post-transcriptionally modified ribonucleic acids

    PubMed Central

    Sample, Paul J.; Gaston, Kirk W.; Alfonzo, Juan D.; Limbach, Patrick A.

    2015-01-01

    Ribosomal ribonucleic acid (RNA), transfer RNA and other biological or synthetic RNA polymers can contain nucleotides that have been modified by the addition of chemical groups. Traditional Sanger sequencing methods cannot establish the chemical nature and sequence of these modified-nucleotide containing oligomers. Mass spectrometry (MS) has become the conventional approach for determining the nucleotide composition, modification status and sequence of modified RNAs. Modified RNAs are analyzed by MS using collision-induced dissociation tandem mass spectrometry (CID MS/MS), which produces a complex dataset of oligomeric fragments that must be interpreted to identify and place modified nucleosides within the RNA sequence. Here we report the development of RoboOligo, an interactive software program for the robust analysis of data generated by CID MS/MS of RNA oligomers. There are three main functions of RoboOligo: (i) automated de novo sequencing via the local search paradigm. (ii) Manual sequencing with real-time spectrum labeling and cumulative intensity scoring. (iii) A hybrid approach, coined ‘variable sequencing’, which combines the user intuition of manual sequencing with the high-throughput sampling of automated de novo sequencing. PMID:25820423

  11. Quantitative IR microscopy and spectromics open the way to 3D digital pathology.

    PubMed

    Bobroff, Vladimir; Chen, Hsiang-Hsin; Delugin, Maylis; Javerzat, Sophie; Petibois, Cyril

    2017-04-01

    Currently, only mass-spectrometry (MS) microscopy brings a quantitative analysis of chemical contents of tissue samples in 3D. Here, the reconstruction of a 3D quantitative chemical images of a biological tissue by FTIR spectro-microscopy is reported. An automated curve-fitting method is developed to extract all intense absorption bands constituting IR spectra. This innovation benefits from three critical features: (1) the correction of raw IR spectra to make them quantitatively comparable; (2) the automated and iterative data treatment allowing to transfer the IR-absorption spectrum into a IR-band spectrum; (3) the reconstruction of an 3D IR-band matrix (x, y, z for voxel position and a 4 th dimension with all IR-band parameters). Spectromics, which is a new method for exploiting spectral data for tissue metadata reconstruction, is proposed to further translate the related chemical information in 3D, as biochemical and anatomical tissue parameters. An example is given with oxidative stress distribution and the reconstruction of blood vessels in tissues. The requirements of IR microscopy instrumentation to propose 3D digital histology as a clinical routine technology is briefly discussed. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Microbiology of beef carcasses before and after slaughterline automation.

    PubMed Central

    Whelehan, O. P.; Hudson, W. R.; Roberts, T. A.

    1986-01-01

    The bacterial status of beef carcasses at a commercial abattoir was monitored before and after slaughterline automation. Bacterial counts did not differ significantly overall (P greater than 0.05) between the original manual line and the automated line for either morning or afternoon slaughter. On the manual line counts in the morning were lower than those from carcasses slaughtered in the afternoon, but on the automated line there was no difference between morning and afternoon counts. Due to highly significant line X sample site interaction for both morning and afternoon counts, overall differences among sample sites were not found by analysis of variance. However, principal components analysis revealed a significant shift in bacterial contamination among some sites due to slaughterline changes. The incidence of Enterobacteriaceae increased marginally following automation. PMID:3701039

  13. SPICODYN: A Toolbox for the Analysis of Neuronal Network Dynamics and Connectivity from Multi-Site Spike Signal Recordings.

    PubMed

    Pastore, Vito Paolo; Godjoski, Aleksandar; Martinoia, Sergio; Massobrio, Paolo

    2018-01-01

    We implemented an automated and efficient open-source software for the analysis of multi-site neuronal spike signals. The software package, named SPICODYN, has been developed as a standalone windows GUI application, using C# programming language with Microsoft Visual Studio based on .NET framework 4.5 development environment. Accepted input data formats are HDF5, level 5 MAT and text files, containing recorded or generated time series spike signals data. SPICODYN processes such electrophysiological signals focusing on: spiking and bursting dynamics and functional-effective connectivity analysis. In particular, for inferring network connectivity, a new implementation of the transfer entropy method is presented dealing with multiple time delays (temporal extension) and with multiple binary patterns (high order extension). SPICODYN is specifically tailored to process data coming from different Multi-Electrode Arrays setups, guarantying, in those specific cases, automated processing. The optimized implementation of the Delayed Transfer Entropy and the High-Order Transfer Entropy algorithms, allows performing accurate and rapid analysis on multiple spike trains from thousands of electrodes.

  14. Retinal blood vessel segmentation using fully convolutional network with transfer learning.

    PubMed

    Jiang, Zhexin; Zhang, Hao; Wang, Yi; Ko, Seok-Bum

    2018-04-26

    Since the retinal blood vessel has been acknowledged as an indispensable element in both ophthalmological and cardiovascular disease diagnosis, the accurate segmentation of the retinal vessel tree has become the prerequisite step for automated or computer-aided diagnosis systems. In this paper, a supervised method is presented based on a pre-trained fully convolutional network through transfer learning. This proposed method has simplified the typical retinal vessel segmentation problem from full-size image segmentation to regional vessel element recognition and result merging. Meanwhile, additional unsupervised image post-processing techniques are applied to this proposed method so as to refine the final result. Extensive experiments have been conducted on DRIVE, STARE, CHASE_DB1 and HRF databases, and the accuracy of the cross-database test on these four databases is state-of-the-art, which also presents the high robustness of the proposed approach. This successful result has not only contributed to the area of automated retinal blood vessel segmentation but also supports the effectiveness of transfer learning when applying deep learning technique to medical imaging. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. New energy transfer dyes for DNA sequencing.

    PubMed Central

    Lee, L G; Spurgeon, S L; Heiner, C R; Benson, S C; Rosenblum, B B; Menchen, S M; Graham, R J; Constantinescu, A; Upadhya, K G; Cassel, J M

    1997-01-01

    We have synthesized a set of four energy transfer dyes and demonstrated their use in automated DNA sequencing. The donor dyes are the 5- or 6-carboxy isomers of 4'-aminomethylfluorescein and the acceptor dyes are a novel set of four 4,7-dichloro-substituted rhodamine dyes which have narrower emission spectra than the standard, unsubstituted rhodamines. A rigid amino acid linker, 4-aminomethylbenzoic acid, was used to separate the dyes. The brightness of each dye in an automated sequencing instrument equipped with a dual line argon ion laser (488 and 514 nm excitation) was 2-2.5 times greater than the standard dye-primers with a 2 times reduction in multicomponent noise. The overall improvement in signal-to-noise was 4- to 5-fold. The utility of the new dye set was demonstrated by sequencing of a BAC DNA with an 80 kb insert. Measurement of the extinction coefficients and the relative quantum yields of the dichlororhodamine components of the energy transfer dyes showed their values were reduced by 20-25% compared with the dichlororhodamine dyes alone. PMID:9207029

  16. Automated extraction of DNA from biological stains on fabric from crime cases. A comparison of a manual and three automated methods.

    PubMed

    Stangegaard, Michael; Hjort, Benjamin B; Hansen, Thomas N; Hoflund, Anders; Mogensen, Helle S; Hansen, Anders J; Morling, Niels

    2013-05-01

    The presence of PCR inhibitors in extracted DNA may interfere with the subsequent quantification and short tandem repeat (STR) reactions used in forensic genetic DNA typing. DNA extraction from fabric for forensic genetic purposes may be challenging due to the occasional presence of PCR inhibitors that may be co-extracted with the DNA. Using 120 forensic trace evidence samples consisting of various types of fabric, we compared three automated DNA extraction methods based on magnetic beads (PrepFiler Express Forensic DNA Extraction Kit on an AutoMate Express, QIAsyphony DNA Investigator kit either with the sample pre-treatment recommended by Qiagen or an in-house optimized sample pre-treatment on a QIAsymphony SP) and one manual method (Chelex) with the aim of reducing the amount of PCR inhibitors in the DNA extracts and increasing the proportion of reportable STR-profiles. A total of 480 samples were processed. The highest DNA recovery was obtained with the PrepFiler Express kit on an AutoMate Express while the lowest DNA recovery was obtained using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen. Extraction using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen resulted in the lowest percentage of PCR inhibition (0%) while extraction using manual Chelex resulted in the highest percentage of PCR inhibition (51%). The largest number of reportable STR-profiles was obtained with DNA from samples extracted with the PrepFiler Express kit (75%) while the lowest number was obtained with DNA from samples extracted using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen (41%). Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Development of an automated pre-sampling plan for construction projects : final report.

    DOT National Transportation Integrated Search

    1983-03-01

    The development of an automated pre-sampling plan was undertaken to free the district construction personnel from the cumbersome and time-consuming task of preparing such plans manually. A computer program was written and linked to a data file which ...

  18. Orbital transfer vehicle launch operations study. Processing flows. Volume 3

    NASA Technical Reports Server (NTRS)

    1986-01-01

    The Orbit Transfer Vehicle (OTV) processing flow and Resource Identification Sheets (RISs) for the ground based orbit transfer vehicle and for the space based orbit transfer vehicle are the primary source of information for the rest of the Kennedy Space Center (KSC) OTV Launch Operations Study. Work is presented which identifies KSC facility requirements for the OTV Program, simplifies or automates either flow though the application technology, revises test practices and identifies crew sizes or skills used. These flows were used as the primary point of departure from current operations and practices. Analyses results were documented by revising the appropriate RIS page.

  19. Description and Applications for an Automated Inertial Azimuth Measuring System,

    DTIC Science & Technology

    specialized field environment. The present system consists of two integrated inertial sensors , an angle transfer system, a tiltmeter array and a...optical path. Highly sensitive tiltmeters are used to measure and correct for errors due to base motions of the inertial sensors . Data handling and...microprocessor. The inertial sensors use gimbal-mounted rate gyrocompasses to indicate the azimuths of two transfer mirrors with respect to true North. The

  20. An automated rendezvous and capture system design concept for the cargo transfer vehicle and Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Fuchs, Ron; Marsh, Steven

    1991-01-01

    A rendezvous sensor system concept was developed for the cargo transfer vehicle (CTV) to autonomously rendezvous with and be captured by Space Station Freedom (SSF). The development of requirements, the design of a unique Lockheed developed sensor concept to meet these requirements, and the system design to place this sensor on the CTV and rendezvous with the SSF are described .

  1. [The actual possibilities of robotic microscopy in analysis automation and laboratory telemedicine].

    PubMed

    Medovyĭ, V S; Piatnitskiĭ, A M; Sokolinskiĭ, B Z; Balugian, R Sh

    2012-10-01

    The article discusses the possibilities of automation microscopy complexes manufactured by Cellavision and MEKOS to perform the medical analyses of blood films and other biomaterials. The joint work of the complex and physician in the regimen of automatic load stages, screening, sampling and sorting on types with simple morphology, visual sorting of sub-sample with complex morphology provides significant increase of method sensitivity, load decrease and enhancement of physician work conditions. The information technologies, the virtual slides and laboratory telemedicine included permit to develop the representative samples of rare types and pathologies to promote automation methods and medical research targets.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Egorov, Oleg; O'Hara, Matthew J.; Grate, Jay W.

    An automated fluidic instrument is described that rapidly determines the total 99Tc content of aged nuclear waste samples, where the matrix is chemically and radiologically complex and the existing speciation of the 99Tc is variable. The monitor links microwave-assisted sample preparation with an automated anion exchange column separation and detection using a flow-through solid scintillator detector. The sample preparation steps acidify the sample, decompose organics, and convert all Tc species to the pertechnetate anion. The column-based anion exchange procedure separates the pertechnetate from the complex sample matrix, so that radiometric detection can provide accurate measurement of 99Tc. We developed amore » preprogrammed spike addition procedure to automatically determine matrix-matched calibration. The overall measurement efficiency that is determined simultaneously provides a self-diagnostic parameter for the radiochemical separation and overall instrument function. Continuous, automated operation was demonstrated over the course of 54 h, which resulted in the analysis of 215 samples plus 54 hly spike-addition samples, with consistent overall measurement efficiency for the operation of the monitor. A sample can be processed and measured automatically in just 12.5 min with a detection limit of 23.5 Bq/mL of 99Tc in low activity waste (0.495 mL sample volume), with better than 10% RSD precision at concentrations above the quantification limit. This rapid automated analysis method was developed to support nuclear waste processing operations planned for the Hanford nuclear site.« less

  3. ATV Ingress

    NASA Image and Video Library

    2014-08-13

    ISS040-E-091921 (13 Aug. 2014) --- European Space Agency astronaut Alexander Gerst, Expedition 40 flight engineer, prepares to remove the docking mechanism to gain access to the hatch of the newly attached "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5).

  4. ATV Ingress

    NASA Image and Video Library

    2014-08-13

    ISS040-E-091918 (13 Aug. 2014) --- European Space Agency astronaut Alexander Gerst, Expedition 40 flight engineer, prepares to remove the docking mechanism to gain access to the hatch of the newly attached "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5).

  5. ATV Ingress

    NASA Image and Video Library

    2014-08-13

    ISS040-E-091919 (13 Aug. 2014) --- European Space Agency astronaut Alexander Gerst, Expedition 40 flight engineer, prepares to remove the docking mechanism to gain access to the hatch of the newly attached "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5).

  6. ATV Ingress

    NASA Image and Video Library

    2014-08-13

    ISS040-E-091922 (13 Aug. 2014) --- European Space Agency astronaut Alexander Gerst, Expedition 40 flight engineer, prepares to remove the docking mechanism to gain access to the hatch of the newly attached "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5).

  7. ATV Ingress

    NASA Image and Video Library

    2014-08-13

    ISS040-E-091969 (13 Aug. 2014) --- Surrounded by stowage containers, European Space Agency astronaut Alexander Gerst, Expedition 40 flight engineer, is pictured in the newly-attached "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5) of the International Space Station.

  8. jsc2014e077199

    NASA Image and Video Library

    2014-08-12

    DATE: 8-12-14 LOCATION: Bldg. 30 - FCR-1 (30M/231) SUBJECT: ISS Flight Controllers during docking of the "Georges Lemaitre" Automated Transfer Vehicle-5 to the aft port of the Zvezda Service Module. PHOTOGRAPHER: Lauren Harnett

  9. jsc2014e077215

    NASA Image and Video Library

    2014-08-12

    DATE: 8-12-14 LOCATION: Bldg. 30 - FCR-1 (30M/231) SUBJECT: ISS Flight Controllers during docking of the "Georges Lemaitre" Automated Transfer Vehicle-5 to the aft port of the Zvezda Service Module. PHOTOGRAPHER: Lauren Harnett

  10. Automated extraction for the analysis of 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH) in urine using a six-head probe Hamilton Microlab 2200 system and gas chromatography-mass spectrometry.

    PubMed

    Whitter, P D; Cary, P L; Leaton, J I; Johnson, J E

    1999-01-01

    An automated extraction scheme for the analysis of 11 -nor-delta9-tetrahydrocannabinol-9-carboxylic acid using the Hamilton Microlab 2200, which was modified for gravity-flow solid-phase extraction, has been evaluated. The Hamilton was fitted with a six-head probe, a modular valve positioner, and a peristaltic pump. The automated method significantly increased sample throughput, improved assay consistency, and reduced the time spent performing the extraction. Extraction recovery for the automated method was > 90%. The limit of detection, limit of quantitation, and upper limit of linearity were equivalent to the manual method: 1.5, 3.0, and 300 ng/mL, respectively. Precision at the 15-ng/mL cut-off was as follows: mean = 14.4, standard deviation = 0.5, coefficient of variation = 3.5%. Comparison of 38 patient samples, extracted by the manual and automated extraction methods, demonstrated the following correlation statistics: r = .991, slope 1.029, and y-intercept -2.895. Carryover was < 0.3% at 1000 ng/mL. Aliquoting/extraction time for the automated method (48 urine samples) was 50 min, and the manual procedure required approximately 2.5 h. The automated aliquoting/extraction method on the Hamilton Microlab 2200 and its use in forensic applications are reviewed.

  11. Fail-over file transfer process

    NASA Technical Reports Server (NTRS)

    Semancik, Susan K. (Inventor); Conger, Annette M. (Inventor)

    2005-01-01

    The present invention provides a fail-over file transfer process to handle data file transfer when the transfer is unsuccessful in order to avoid unnecessary network congestion and enhance reliability in an automated data file transfer system. If a file cannot be delivered after attempting to send the file to a receiver up to a preset number of times, and the receiver has indicated the availability of other backup receiving locations, then the file delivery is automatically attempted to one of the backup receiving locations up to the preset number of times. Failure of the file transfer to one of the backup receiving locations results in a failure notification being sent to the receiver, and the receiver may retrieve the file from the location indicated in the failure notification when ready.

  12. Space biology initiative program definition review. Trade study 1: Automation costs versus crew utilization

    NASA Technical Reports Server (NTRS)

    Jackson, L. Neal; Crenshaw, John, Sr.; Hambright, R. N.; Nedungadi, A.; Mcfayden, G. M.; Tsuchida, M. S.

    1989-01-01

    A significant emphasis upon automation within the Space Biology Initiative hardware appears justified in order to conserve crew labor and crew training effort. Two generic forms of automation were identified: automation of data and information handling and decision making, and the automation of material handling, transfer, and processing. The use of automatic data acquisition, expert systems, robots, and machine vision will increase the volume of experiments and quality of results. The automation described may also influence efforts to miniaturize and modularize the large array of SBI hardware identified to date. The cost and benefit model developed appears to be a useful guideline for SBI equipment specifiers and designers. Additional refinements would enhance the validity of the model. Two NASA automation pilot programs, 'The Principal Investigator in a Box' and 'Rack Mounted Robots' were investigated and found to be quite appropriate for adaptation to the SBI program. There are other in-house NASA efforts that provide technology that may be appropriate for the SBI program. Important data is believed to exist in advanced medical labs throughout the U.S., Japan, and Europe. The information and data processing in medical analysis equipment is highly automated and future trends reveal continued progress in this area. However, automation of material handling and processing has progressed in a limited manner because the medical labs are not affected by the power and space constraints that Space Station medical equipment is faced with. Therefore, NASA's major emphasis in automation will require a lead effort in the automation of material handling to achieve optimal crew utilization.

  13. REBOCOL (Robotic Calorimetry): An automated NDA (Nondestructive assay) calorimetry and gamma isotopic system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hurd, J.R.; Bonner, C.A.; Ostenak, C.A.

    1989-01-01

    ROBOCAL, which is presently being developed and tested at Los Alamos National Laboratory, is a full-scale, prototypical robotic system, for remote calorimetric and gamma-ray analysis of special nuclear materials. It integrates a fully automated, multi-drawer, vertical stacker-retriever system for staging unmeasured nuclear materials, and a fully automated gantry robot for computer-based selection and transfer of nuclear materials to calorimetric and gamma-ray measurement stations. Since ROBOCAL is designed for minimal operator intervention, a completely programmed user interface and data-base system are provided to interact with the automated mechanical and assay systems. The assay system is designed to completely integrate calorimetric andmore » gamma-ray data acquisition and to perform state-of-the-art analyses on both homogeneous and heterogeneous distributions of nuclear materials in a wide variety of matrices. 10 refs., 10 figs., 4 tabs.« less

  14. Can the Roche hemolysis index be used for automated determination of cell-free hemoglobin? A comparison to photometric assays.

    PubMed

    Petrova, Darinka Todorova; Cocisiu, Gabriela Ariadna; Eberle, Christoph; Rhode, Karl-Heinz; Brandhorst, Gunnar; Walson, Philip D; Oellerich, Michael

    2013-09-01

    The aim of this study was to develop a novel method for automated quantification of cell-free hemoglobin (fHb) based on the HI (Roche Diagnostics). The novel fHb method based on the HI was correlated with fHb measured using the triple wavelength methods of both Harboe [fHb, g/L = (0.915 * HI + 2.634)/100] and Fairbanks et al. [fHb, g/L = (0.917 * HI + 2.131)/100]. fHb concentrations were estimated from the HI using the Roche Modular automated platform in self-made and commercially available quality controls, as well as samples from a proficiency testing scheme (INSTAND). The fHb using Roche automated HI results were then compared to results obtained using the traditional spectrophotometric assays for one hundred plasma samples with varying degrees of hemolysis, lipemia and/or bilirubinemia. The novel method using automated HI quantification on the Roche Modular clinical chemistry platform correlated well with results using the classical methods in the 100 patient samples (Harboe: r = 0.9284; Fairbanks et al.: r = 0.9689) and recovery was good for self-made controls. However, commercially available quality controls showed poor recovery due to an unidentified matrix problem. The novel method produced reliable determination of fHb in samples without interferences. However, poor recovery using commercially available fHb quality control samples currently greatly limits its usefulness. © 2013.

  15. The laboratory of the 1990s—Planning for total automation

    PubMed Central

    Brunner, Linda A.

    1992-01-01

    The analytical laboratory of the 1990s must be able to meet and accommodate the rapid evolution of modern-day technology. One such area is laboratory automation. Total automation may be seen as the coupling of computerized sample tracking, electronic documentation and data reduction with automated sample handling, preparation and analysis, resulting in a complete analytical procedure with minimal human involvement. Requirements may vary from one laboratory or facility to another, so the automation has to be flexible enough to cover a wide range of applications, and yet fit into specific niches depending on individual needs. Total automation must be planned for, well in advance, if the endeavour is to be a success. Space, laboratory layout, proper equipment, and the availability and access to necessary utilities must be taken into account. Adequate training and experience of the personnel working with the technology must also be ensured. In addition, responsibilities of installation, programming maintenance and operation have to be addressed. Proper time management and the efficient implementation and use of total automation are also crucial to successful operations. This paper provides insights into laboratory organization and requirements, as well as discussing the management issues that must be faced when automating laboratory procedures. PMID:18924925

  16. Development of automation software for neutron activation analysis process in Malaysian nuclear agency

    NASA Astrophysics Data System (ADS)

    Yussup, N.; Rahman, N. A. A.; Ibrahim, M. M.; Mokhtar, M.; Salim, N. A. A.; Soh@Shaari, S. C.; Azman, A.

    2017-01-01

    Neutron Activation Analysis (NAA) process has been established in Malaysian Nuclear Agency (Nuclear Malaysia) since 1980s. Most of the procedures established especially from sample registration to sample analysis are performed manually. These manual procedures carried out by the NAA laboratory personnel are time consuming and inefficient. Hence, a software to support the system automation is developed to provide an effective method to replace redundant manual data entries and produce faster sample analysis and calculation process. This paper describes the design and development of automation software for NAA process which consists of three sub-programs. The sub-programs are sample registration, hardware control and data acquisition; and sample analysis. The data flow and connection between the sub-programs will be explained. The software is developed by using National Instrument LabView development package.

  17. ICECAP: an integrated, general-purpose, automation-assisted IC50/EC50 assay platform.

    PubMed

    Li, Ming; Chou, Judy; King, Kristopher W; Jing, Jing; Wei, Dong; Yang, Liyu

    2015-02-01

    IC50 and EC50 values are commonly used to evaluate drug potency. Mass spectrometry (MS)-centric bioanalytical and biomarker labs are now conducting IC50/EC50 assays, which, if done manually, are tedious and error-prone. Existing bioanalytical sample preparation automation systems cannot meet IC50/EC50 assay throughput demand. A general-purpose, automation-assisted IC50/EC50 assay platform was developed to automate the calculations of spiking solutions and the matrix solutions preparation scheme, the actual spiking and matrix solutions preparations, as well as the flexible sample extraction procedures after incubation. In addition, the platform also automates the data extraction, nonlinear regression curve fitting, computation of IC50/EC50 values, graphing, and reporting. The automation-assisted IC50/EC50 assay platform can process the whole class of assays of varying assay conditions. In each run, the system can handle up to 32 compounds and up to 10 concentration levels per compound, and it greatly improves IC50/EC50 assay experimental productivity and data processing efficiency. © 2014 Society for Laboratory Automation and Screening.

  18. Automation of serum (1→3)-beta-D-glucan testing allows reliable and rapid discrimination of patients with and without candidemia.

    PubMed

    Prüller, Florian; Wagner, Jasmin; Raggam, Reinhard B; Hoenigl, Martin; Kessler, Harald H; Truschnig-Wilders, Martie; Krause, Robert

    2014-07-01

    Testing for (1→3)-beta-D-glucan (BDG) is used for detection of invasive fungal infection. However, current assays lack automation and the ability to conduct rapid single-sample testing. The Fungitell assay was adopted for automation and evaluated using clinical samples from patients with culture-proven candidemia and from culture-negative controls in duplicate. A comparison with the standard assay protocol was made in order to establish analytical specifications. With the automated protocol, the analytical measuring range was 8-2500 pg/ml of BDG, and precision testing resulted in coefficients of variation that ranged from 3.0% to 5.5%. Samples from 15 patients with culture-proven candidemia and 94 culture-negative samples were evaluated. All culture-proven samples showed BDG values >80 pg/ml (mean 1247 pg/ml; range, 116-2990 pg/ml), which were considered positive. Of the 94 culture-negative samples, 92 had BDG values <60 pg/ml (mean, 28 pg/ml), which were considered to be negative, and 2 samples were false-positive (≥80 pg/ml; up to 124 pg/ml). Results could be obtained within 45 min and showed excellent agreement with results obtained with the standard assay protocol. The automated Fungitell assay proved to be reliable and rapid for diagnosis of candidemia. It was demonstrated to be feasible and cost efficient for both single-sample and large-scale testing of serum BDG. Its 1-h time-to-result will allow better support for clinicians in the management of antifungal therapy. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. A compendium of controlled diffusion blades generated by an automated inverse design procedure

    NASA Technical Reports Server (NTRS)

    Sanz, Jose M.

    1989-01-01

    A set of sample cases was produced to test an automated design procedure developed at the NASA Lewis Research Center for the design of controlled diffusion blades. The range of application of the automated design procedure is documented. The results presented include characteristic compressor and turbine blade sections produced with the automated design code as well as various other airfoils produced with the base design method prior to the incorporation of the automated procedure.

  20. Novel Acoustic Loading of a Mass Spectrometer: Toward Next-Generation High-Throughput MS Screening.

    PubMed

    Sinclair, Ian; Stearns, Rick; Pringle, Steven; Wingfield, Jonathan; Datwani, Sammy; Hall, Eric; Ghislain, Luke; Majlof, Lars; Bachman, Martin

    2016-02-01

    High-throughput, direct measurement of substrate-to-product conversion by label-free detection, without the need for engineered substrates or secondary assays, could be considered the "holy grail" of drug discovery screening. Mass spectrometry (MS) has the potential to be part of this ultimate screening solution, but is constrained by the limitations of existing MS sample introduction modes that cannot meet the throughput requirements of high-throughput screening (HTS). Here we report data from a prototype system (Echo-MS) that uses acoustic droplet ejection (ADE) to transfer femtoliter-scale droplets in a rapid, precise, and accurate fashion directly into the MS. The acoustic source can load samples into the MS from a microtiter plate at a rate of up to three samples per second. The resulting MS signal displays a very sharp attack profile and ions are detected within 50 ms of activation of the acoustic transducer. Additionally, we show that the system is capable of generating multiply charged ion species from simple peptides and large proteins. The combination of high speed and low sample volume has significant potential within not only drug discovery, but also other areas of the industry. © 2015 Society for Laboratory Automation and Screening.

  1. Automated Protein Biomarker Analysis: on-line extraction of clinical samples by Molecularly Imprinted Polymers

    NASA Astrophysics Data System (ADS)

    Rossetti, Cecilia; Świtnicka-Plak, Magdalena A.; Grønhaug Halvorsen, Trine; Cormack, Peter A. G.; Sellergren, Börje; Reubsaet, Léon

    2017-03-01

    Robust biomarker quantification is essential for the accurate diagnosis of diseases and is of great value in cancer management. In this paper, an innovative diagnostic platform is presented which provides automated molecularly imprinted solid-phase extraction (MISPE) followed by liquid chromatography-mass spectrometry (LC-MS) for biomarker determination using ProGastrin Releasing Peptide (ProGRP), a highly sensitive biomarker for Small Cell Lung Cancer, as a model. Molecularly imprinted polymer microspheres were synthesized by precipitation polymerization and analytical optimization of the most promising material led to the development of an automated quantification method for ProGRP. The method enabled analysis of patient serum samples with elevated ProGRP levels. Particularly low sample volumes were permitted using the automated extraction within a method which was time-efficient, thereby demonstrating the potential of such a strategy in a clinical setting.

  2. Characterization of high explosive particles using cluster secondary ion mass spectrometry.

    PubMed

    Gillen, Greg; Mahoney, Christine; Wight, Scott; Lareau, Richard

    2006-01-01

    The use of secondary ion mass spectrometry (SIMS) for the detection and spatially resolved analysis of individual high explosive particles is described. A C(8) (-) carbon cluster primary ion beam was used in a commercial SIMS instrument to analyze samples of high explosives dispersed as particles on silicon substrates. In comparison with monatomic primary ion bombardment, the carbon cluster primary ion beam was found to greatly enhance characteristic secondary ion signals from the explosive compounds while causing minimal beam-induced degradation. The resistance of these compounds to degradation under ion bombardment allows explosive particles to be analyzed under high primary ion dose bombardment (dynamic SIMS) conditions, facilitating the rapid acquisition of spatially resolved molecular information. The use of cluster SIMS combined with computer control of the sample stage position allows for the automated identification and counting of explosive particle distributions on silicon surfaces. This will be useful for characterizing the efficiency of transfer of particulates in trace explosive detection portal collectors and/or swipes utilized for ion mobility spectrometry applications.

  3. Extraction studies. Final report, May 6, 1996--September 30, 1997

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    During the first week of this effort, an Alpkem RFA-300 4-channel automated chemical analyzer was transferred to the basement of building 42 at TA-46 for the purpose of performing extraction studies. Initially, this instrumentation was applied to soil samples known to contain DNA. Using the SFA (Segmented Flow Analysis) technique, several fluidic systems were evaluated to perform on-line filtration of several varieties of soil obtained from Cheryl Kuske and Kaysie Banton (TA-43, Bldg. 1). Progress reports were issued monthly beginning May 15, 1996. Early in 1997 there was a shift from the conventional 2-phase system (aqueous + air) to amore » 3-phase system (oil + aqueous + air) to drastically reduce sample size and reagent consumption. Computer animation was recorded on videotape for presentations. The time remaining on the subcontract was devoted to setting up existing equipment to incorporate the 3rd phase (a special fluorocarbon oil obtained from DuPont).« less

  4. Comparability of automated human induced pluripotent stem cell culture: a pilot study.

    PubMed

    Archibald, Peter R T; Chandra, Amit; Thomas, Dave; Chose, Olivier; Massouridès, Emmanuelle; Laâbi, Yacine; Williams, David J

    2016-12-01

    Consistent and robust manufacturing is essential for the translation of cell therapies, and the utilisation automation throughout the manufacturing process may allow for improvements in quality control, scalability, reproducibility and economics of the process. The aim of this study was to measure and establish the comparability between alternative process steps for the culture of hiPSCs. Consequently, the effects of manual centrifugation and automated non-centrifugation process steps, performed using TAP Biosystems' CompacT SelecT automated cell culture platform, upon the culture of a human induced pluripotent stem cell (hiPSC) line (VAX001024c07) were compared. This study, has demonstrated that comparable morphologies and cell diameters were observed in hiPSCs cultured using either manual or automated process steps. However, non-centrifugation hiPSC populations exhibited greater cell yields, greater aggregate rates, increased pluripotency marker expression, and decreased differentiation marker expression compared to centrifugation hiPSCs. A trend for decreased variability in cell yield was also observed after the utilisation of the automated process step. This study also highlights the detrimental effect of the cryopreservation and thawing processes upon the growth and characteristics of hiPSC cultures, and demonstrates that automated hiPSC manufacturing protocols can be successfully transferred between independent laboratories.

  5. Artificial intelligence in fracture detection: transfer learning from deep convolutional neural networks.

    PubMed

    Kim, D H; MacKinnon, T

    2018-05-01

    To identify the extent to which transfer learning from deep convolutional neural networks (CNNs), pre-trained on non-medical images, can be used for automated fracture detection on plain radiographs. The top layer of the Inception v3 network was re-trained using lateral wrist radiographs to produce a model for the classification of new studies as either "fracture" or "no fracture". The model was trained on a total of 11,112 images, after an eightfold data augmentation technique, from an initial set of 1,389 radiographs (695 "fracture" and 694 "no fracture"). The training data set was split 80:10:10 into training, validation, and test groups, respectively. An additional 100 wrist radiographs, comprising 50 "fracture" and 50 "no fracture" images, were used for final testing and statistical analysis. The area under the receiver operator characteristic curve (AUC) for this test was 0.954. Setting the diagnostic cut-off at a threshold designed to maximise both sensitivity and specificity resulted in values of 0.9 and 0.88, respectively. The AUC scores for this test were comparable to state-of-the-art providing proof of concept for transfer learning from CNNs in fracture detection on plain radiographs. This was achieved using only a moderate sample size. This technique is largely transferable, and therefore, has many potential applications in medical imaging, which may lead to significant improvements in workflow productivity and in clinical risk reduction. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  6. ATV ops

    NASA Image and Video Library

    2013-06-18

    ISS036-E-009219 (18 June 2013) --- Russian cosmonaut Pavel Vinogradov, Expedition 36 commander, performs cargo operations in the European Space Agency's Automated Transfer Vehicle-4 (ATV-4) "Albert Einstein" currently docked to the Zvezda Service Module of the International Space Station.

  7. Unpacking of ATV

    NASA Image and Video Library

    2013-07-02

    ISS036-E-013924 (2 July 2013) --- NASA astronaut Chris Cassidy, Expedition 36 flight engineer, works in the European Space Agency's Automated Transfer Vehicle-4 (ATV-4) "Albert Einstein" currently docked to the Zvezda Service Module of the International Space Station.

  8. A MICROPROCESSOR ASCII CHARACTER BUFFERING SYSTEM

    EPA Science Inventory

    A microprocessor buffering system (MBS) was developed at the Environmental Monitoring and Support Laboratory -Cincinnati (EMSL-CI) to provide an efficient transfer for serial ASCII information between intelligent instrument systema and a Data General NOVA laboratory automation co...

  9. 76 FR 39385 - Payment Policy Change for Access to NOAA Environmental Data, Information, and Related Products...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-06

    ... accepted forms of payment are Visa, MasterCard, American Express, Discover, wire transfers and Automated.... currency, by VISA, MasterCard, American Express, and Discover. Cardholder's name, charge card number...

  10. LAMA Preconference and Program Highlights.

    ERIC Educational Resources Information Center

    Library Administration & Management, 1988

    1988-01-01

    Highlights events of the Library Administration and Management Association 1988 conference, including presentation of awards and programs on: (1) transfer of training; (2) hiring; (3) mentoring; (4) acquisitions automation; (5) library building consultation; and (6) managing shared systems. (MES)

  11. Kuipers configures the GCP in the ATV-3

    NASA Image and Video Library

    2012-04-06

    ISS030-E-210829 (6 April 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, configures the Gas Control Panel (GCP) in the Automated Transfer Vehicle (ATV-3) currently docked with the International Space Station.

  12. Kuipers configures the GCP in the ATV-3

    NASA Image and Video Library

    2012-04-06

    ISS030-E-210810 (6 April 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, configures the Gas Control Panel (GCP) in the Automated Transfer Vehicle (ATV-3) currently docked with the International Space Station.

  13. Miniaturization of High-Throughput Epigenetic Methyltransferase Assays with Acoustic Liquid Handling.

    PubMed

    Edwards, Bonnie; Lesnick, John; Wang, Jing; Tang, Nga; Peters, Carl

    2016-02-01

    Epigenetics continues to emerge as an important target class for drug discovery and cancer research. As programs scale to evaluate many new targets related to epigenetic expression, new tools and techniques are required to enable efficient and reproducible high-throughput epigenetic screening. Assay miniaturization increases screening throughput and reduces operating costs. Echo liquid handlers can transfer compounds, samples, reagents, and beads in submicroliter volumes to high-density assay formats using only acoustic energy-no contact or tips required. This eliminates tip costs and reduces the risk of reagent carryover. In this study, we demonstrate the miniaturization of a methyltransferase assay using Echo liquid handlers and two different assay technologies: AlphaLISA from PerkinElmer and EPIgeneous HTRF from Cisbio. © 2015 Society for Laboratory Automation and Screening.

  14. Method for near-real-time continuous air monitoring of phosgene, hydrogen cyanide, and cyanogen chloride

    NASA Astrophysics Data System (ADS)

    Lattin, Frank G.; Paul, Donald G.

    1996-11-01

    A sorbent-based gas chromatographic method provides continuous quantitative measurement of phosgene, hydrogen cyanide, and cyanogen chloride in ambient air. These compounds are subject to workplace exposure limits as well as regulation under terms of the Chemical Arms Treaty and Title III of the 1990 Clean Air Act amendments. The method was developed for on-sit use in a mobile laboratory during remediation operations. Incorporated into the method are automated multi-level calibrations at time weighted average concentrations, or lower. Gaseous standards are prepared in fused silica lined air sampling canisters, then transferred to the analytical system through dynamic spiking. Precision and accuracy studies performed to validate the method are described. Also described are system deactivation and passivation techniques critical to optimum method performance.

  15. Flexible End2End Workflow Automation of Hit-Discovery Research.

    PubMed

    Holzmüller-Laue, Silke; Göde, Bernd; Thurow, Kerstin

    2014-08-01

    The article considers a new approach of more complex laboratory automation at the workflow layer. The authors purpose the automation of end2end workflows. The combination of all relevant subprocesses-whether automated or manually performed, independently, and in which organizational unit-results in end2end processes that include all result dependencies. The end2end approach focuses on not only the classical experiments in synthesis or screening, but also on auxiliary processes such as the production and storage of chemicals, cell culturing, and maintenance as well as preparatory activities and analyses of experiments. Furthermore, the connection of control flow and data flow in the same process model leads to reducing of effort of the data transfer between the involved systems, including the necessary data transformations. This end2end laboratory automation can be realized effectively with the modern methods of business process management (BPM). This approach is based on a new standardization of the process-modeling notation Business Process Model and Notation 2.0. In drug discovery, several scientific disciplines act together with manifold modern methods, technologies, and a wide range of automated instruments for the discovery and design of target-based drugs. The article discusses the novel BPM-based automation concept with an implemented example of a high-throughput screening of previously synthesized compound libraries. © 2014 Society for Laboratory Automation and Screening.

  16. Customized ATP towpreg. [Automated Tow Placement

    NASA Technical Reports Server (NTRS)

    Sandusky, Donald A.; Marchello, Joseph M.; Baucom, Robert M.; Johnston, Norman J.

    1992-01-01

    Automated tow placement (ATP) utilizes robotic technology to lay down adjacent polymer-matrix-impregnated carbon fiber tows on a tool surface. Consolidation and cure during ATP requires that void elimination and polymer matrix adhesion be accomplished in the short period of heating and pressure rolling that follows towpreg ribbon placement from the robot head to the tool. This study examined the key towpreg ribbon properties and dimensions which play a significant role in ATP. Analysis of the heat transfer process window indicates that adequate heating can be achieved at lay down rates as high as 1 m/sec. While heat transfer did not appear to be the limiting factor, resin flow and fiber movement into tow lap gaps could be. Accordingly, consideration was given to towpreg ribbon having uniform yet non-rectangular cross sections. Dimensional integrity of the towpreg ribbon combined with customized ribbon architecture offer great promise for processing advances in ATP of high performance composites.

  17. Coordinated control of a dual-arm dexterous robot using full immersion telepresence and virtual reality

    NASA Technical Reports Server (NTRS)

    Li, Larry; Cox, Brian; Shelton, Susan; Diftler, Myron

    1994-01-01

    Telepresence is an approach to teleoperation that provides egocentric, intuitive interactions between an operator and a remote environment. This approach takes advantage of the natural cognitive and sensory motor skills of an on-board crew and effectively transfers them to a slave robot. A dual alarm dexterous robot operating under telepresence control has been developed and initial evaluations of the system performing candidate EVA, IVA and planetary geological tasks were conducted. The results of our evaluation showed that telepresence control is very effective in transferring the operator's skills to the slave robot. However, the results also showed that, due to the kinematic and dynamics inconsistencies between the operator and the robot, a limited amount of intelligent automation is also required to carry out some to the tasks. Therefore, several enhancements have been made to the original system to increase the automated capabilities of the control system without losing the benefits of telepresence.

  18. Comprehensive automation of the solid phase extraction gas chromatographic mass spectrometric analysis (SPE-GC/MS) of opioids, cocaine, and metabolites from serum and other matrices.

    PubMed

    Lerch, Oliver; Temme, Oliver; Daldrup, Thomas

    2014-07-01

    The analysis of opioids, cocaine, and metabolites from blood serum is a routine task in forensic laboratories. Commonly, the employed methods include many manual or partly automated steps like protein precipitation, dilution, solid phase extraction, evaporation, and derivatization preceding a gas chromatography (GC)/mass spectrometry (MS) or liquid chromatography (LC)/MS analysis. In this study, a comprehensively automated method was developed from a validated, partly automated routine method. This was possible by replicating method parameters on the automated system. Only marginal optimization of parameters was necessary. The automation relying on an x-y-z robot after manual protein precipitation includes the solid phase extraction, evaporation of the eluate, derivatization (silylation with N-methyl-N-trimethylsilyltrifluoroacetamide, MSTFA), and injection into a GC/MS. A quantitative analysis of almost 170 authentic serum samples and more than 50 authentic samples of other matrices like urine, different tissues, and heart blood on cocaine, benzoylecgonine, methadone, morphine, codeine, 6-monoacetylmorphine, dihydrocodeine, and 7-aminoflunitrazepam was conducted with both methods proving that the analytical results are equivalent even near the limits of quantification (low ng/ml range). To our best knowledge, this application is the first one reported in the literature employing this sample preparation system.

  19. RoboDiff: combining a sample changer and goniometer for highly automated macromolecular crystallography experiments

    PubMed Central

    Nurizzo, Didier; Bowler, Matthew W.; Caserotto, Hugo; Dobias, Fabien; Giraud, Thierry; Surr, John; Guichard, Nicolas; Papp, Gergely; Guijarro, Matias; Mueller-Dieckmann, Christoph; Flot, David; McSweeney, Sean; Cipriani, Florent; Theveneau, Pascal; Leonard, Gordon A.

    2016-01-01

    Automation of the mounting of cryocooled samples is now a feature of the majority of beamlines dedicated to macromolecular crystallography (MX). Robotic sample changers have been developed over many years, with the latest designs increasing capacity, reliability and speed. Here, the development of a new sample changer deployed at the ESRF beamline MASSIF-1 (ID30A-1), based on an industrial six-axis robot, is described. The device, named RoboDiff, includes a high-capacity dewar, acts as both a sample changer and a high-accuracy goniometer, and has been designed for completely unattended sample mounting and diffraction data collection. This aim has been achieved using a high level of diagnostics at all steps of the process from mounting and characterization to data collection. The RoboDiff has been in service on the fully automated endstation MASSIF-1 at the ESRF since September 2014 and, at the time of writing, has processed more than 20 000 samples completely automatically. PMID:27487827

  20. Research on Internal Controls and Auditing. Navy Financial Management Improvement Program. Volume 3.

    DTIC Science & Technology

    1980-06-01

    facilities. NARDAC Pensacola, was formed in October, 1977 with the transfer of the Naval Education and Training Information Support o Activity (NETISA...to NAVDAC and the additional transfer of four other geographically separate data processing centers. Somewhere between 25 to 50 percent of the Navy’s...may change the jobs within the framework of the time and processing resources available. The automated system tells the operations personnel the setup

  1. High-throughput sample processing and sample management; the functional evolution of classical cytogenetic assay towards automation.

    PubMed

    Ramakumar, Adarsh; Subramanian, Uma; Prasanna, Pataje G S

    2015-11-01

    High-throughput individual diagnostic dose assessment is essential for medical management of radiation-exposed subjects after a mass casualty. Cytogenetic assays such as the Dicentric Chromosome Assay (DCA) are recognized as the gold standard by international regulatory authorities. DCA is a multi-step and multi-day bioassay. DCA, as described in the IAEA manual, can be used to assess dose up to 4-6 weeks post-exposure quite accurately but throughput is still a major issue and automation is very essential. The throughput is limited, both in terms of sample preparation as well as analysis of chromosome aberrations. Thus, there is a need to design and develop novel solutions that could utilize extensive laboratory automation for sample preparation, and bioinformatics approaches for chromosome-aberration analysis to overcome throughput issues. We have transitioned the bench-based cytogenetic DCA to a coherent process performing high-throughput automated biodosimetry for individual dose assessment ensuring quality control (QC) and quality assurance (QA) aspects in accordance with international harmonized protocols. A Laboratory Information Management System (LIMS) is designed, implemented and adapted to manage increased sample processing capacity, develop and maintain standard operating procedures (SOP) for robotic instruments, avoid data transcription errors during processing, and automate analysis of chromosome-aberrations using an image analysis platform. Our efforts described in this paper intend to bridge the current technological gaps and enhance the potential application of DCA for a dose-based stratification of subjects following a mass casualty. This paper describes one such potential integrated automated laboratory system and functional evolution of the classical DCA towards increasing critically needed throughput. Published by Elsevier B.V.

  2. Comparison of human expert and computer-automated systems using magnitude-squared coherence (MSC) and bootstrap distribution statistics for the interpretation of pattern electroretinograms (PERGs) in infants with optic nerve hypoplasia (ONH).

    PubMed

    Fisher, Anthony C; McCulloch, Daphne L; Borchert, Mark S; Garcia-Filion, Pamela; Fink, Cassandra; Eleuteri, Antonio; Simpson, David M

    2015-08-01

    Pattern electroretinograms (PERGs) have inherently low signal-to-noise ratios and can be difficult to detect when degraded by pathology or noise. We compare an objective system for automated PERG analysis with expert human interpretation in children with optic nerve hypoplasia (ONH) with PERGs ranging from clear to undetectable. PERGs were recorded uniocularly with chloral hydrate sedation in children with ONH (aged 3.5-35 months). Stimuli were reversing checks of four sizes focused using an optical system incorporating the cycloplegic refraction. Forty PERG records were analysed; 20 selected at random and 20 from eyes with good vision (fellow eyes or eyes with mild ONH) from over 300 records. Two experts identified P50 and N95 of the PERGs after manually deleting trials with movement artefact, slow-wave EEG (4-8 Hz) or other noise from raw data for 150 check reversals. The automated system first identified present/not-present responses using a magnitude-squared coherence criterion and then, for responses confirmed as present, estimated the P50 and N95 cardinal positions as the turning points in local third-order polynomials fitted in the -3 dB bandwidth [0.25 … 45] Hz. Confidence limits were estimated from bootstrap re-sampling with replacement. The automated system uses an interactive Internet-available webpage tool (see http://clinengnhs.liv.ac.uk/esp_perg_1.htm). The automated system detected 28 PERG signals above the noise level (p ≤ 0.05 for H0). Good subjective quality ratings were indicative of significant PERGs; however, poor subjective quality did not necessarily predict non-significant signals. P50 and N95 implicit times showed good agreement between the two experts and between experts and the automated system. For the N95 amplitude measured to P50, the experts differed by an average of 13% consistent with differing interpretations of peaks within noise, while the automated amplitude measure was highly correlated with the expert measures but was proportionally larger. Trial-by-trial review of these data required approximately 6.5 h for each human expert, while automated data processing required <4 min, excluding overheads relating to data transfer. An automated computer system for PERG analysis, using a panel of signal processing and statistical techniques, provides objective present/not-present detection and cursor positioning with explicit confidence intervals. The system achieves, within an efficient and robust statistical framework, estimates of P50 and N95 amplitudes and implicit times similar to those of clinical experts.

  3. 21 CFR 864.5600 - Automated hematocrit instrument.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... measures the packed red cell volume of a blood sample to distinguish normal from abnormal states, such as anemia and erythrocytosis (an increase in the number of red cells). (b) Classification. Class II... § 864.5600 Automated hematocrit instrument. (a) Identification. An automated hematocrit instrument is a...

  4. 21 CFR 864.5600 - Automated hematocrit instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... measures the packed red cell volume of a blood sample to distinguish normal from abnormal states, such as anemia and erythrocytosis (an increase in the number of red cells). (b) Classification. Class II... § 864.5600 Automated hematocrit instrument. (a) Identification. An automated hematocrit instrument is a...

  5. 21 CFR 864.5600 - Automated hematocrit instrument.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... measures the packed red cell volume of a blood sample to distinguish normal from abnormal states, such as anemia and erythrocytosis (an increase in the number of red cells). (b) Classification. Class II... § 864.5600 Automated hematocrit instrument. (a) Identification. An automated hematocrit instrument is a...

  6. 21 CFR 864.5600 - Automated hematocrit instrument.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... measures the packed red cell volume of a blood sample to distinguish normal from abnormal states, such as anemia and erythrocytosis (an increase in the number of red cells). (b) Classification. Class II... § 864.5600 Automated hematocrit instrument. (a) Identification. An automated hematocrit instrument is a...

  7. 21 CFR 864.5600 - Automated hematocrit instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... measures the packed red cell volume of a blood sample to distinguish normal from abnormal states, such as anemia and erythrocytosis (an increase in the number of red cells). (b) Classification. Class II... § 864.5600 Automated hematocrit instrument. (a) Identification. An automated hematocrit instrument is a...

  8. Unattended reaction monitoring using an automated microfluidic sampler and on-line liquid chromatography.

    PubMed

    Patel, Darshan C; Lyu, Yaqi Fara; Gandarilla, Jorge; Doherty, Steve

    2018-04-03

    In-process sampling and analysis is an important aspect of monitoring kinetic profiles and impurity formation or rejection, both in development and during commercial manufacturing. In pharmaceutical process development, the technology of choice for a substantial portion of this analysis is high-performance liquid chromatography (HPLC). Traditionally, the sample extraction and preparation for reaction characterization have been performed manually. This can be time consuming, laborious, and impractical for long processes. Depending on the complexity of the sample preparation, there can be variability introduced by different analysts, and in some cases, the integrity of the sample can be compromised during handling. While there are commercial instruments available for on-line monitoring with HPLC, they lack capabilities in many key areas. Some do not provide integration of the sampling and analysis, while others afford limited flexibility in sample preparation. The current offerings provide a limited number of unit operations available for sample processing and no option for workflow customizability. This work describes development of a microfluidic automated program (MAP) which fully automates the sample extraction, manipulation, and on-line LC analysis. The flexible system is controlled using an intuitive Microsoft Excel based user interface. The autonomous system is capable of unattended reaction monitoring that allows flexible unit operations and workflow customization to enable complex operations and on-line sample preparation. The automated system is shown to offer advantages over manual approaches in key areas while providing consistent and reproducible in-process data. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Non-Contact Conductivity Measurement for Automated Sample Processing Systems

    NASA Technical Reports Server (NTRS)

    Beegle, Luther W.; Kirby, James P.

    2012-01-01

    A new method has been developed for monitoring and control of automated sample processing and preparation especially focusing on desalting of samples before analytical analysis (described in more detail in Automated Desalting Apparatus, (NPO-45428), NASA Tech Briefs, Vol. 34, No. 8 (August 2010), page 44). The use of non-contact conductivity probes, one at the inlet and one at the outlet of the solid phase sample preparation media, allows monitoring of the process, and acts as a trigger for the start of the next step in the sequence (see figure). At each step of the muti-step process, the system is flushed with low-conductivity water, which sets the system back to an overall low-conductivity state. This measurement then triggers the next stage of sample processing protocols, and greatly minimizes use of consumables. In the case of amino acid sample preparation for desalting, the conductivity measurement will define three key conditions for the sample preparation process. First, when the system is neutralized (low conductivity, by washing with excess de-ionized water); second, when the system is acidified, by washing with a strong acid (high conductivity); and third, when the system is at a basic condition of high pH (high conductivity). Taken together, this non-contact conductivity measurement for monitoring sample preparation will not only facilitate automation of the sample preparation and processing, but will also act as a way to optimize the operational time and use of consumables

  10. Automated grain mapping using wide angle convergent beam electron diffraction in transmission electron microscope for nanomaterials.

    PubMed

    Kumar, Vineet

    2011-12-01

    The grain size statistics, commonly derived from the grain map of a material sample, are important microstructure characteristics that greatly influence its properties. The grain map for nanomaterials is usually obtained manually by visual inspection of the transmission electron microscope (TEM) micrographs because automated methods do not perform satisfactorily. While the visual inspection method provides reliable results, it is a labor intensive process and is often prone to human errors. In this article, an automated grain mapping method is developed using TEM diffraction patterns. The presented method uses wide angle convergent beam diffraction in the TEM. The automated technique was applied on a platinum thin film sample to obtain the grain map and subsequently derive grain size statistics from it. The grain size statistics obtained with the automated method were found in good agreement with the visual inspection method.

  11. WATER TREATMENT

    DOEpatents

    Pitman, R.W.; Conley, W.R. Jr.

    1962-12-01

    An automated system for adding clarifying chemicals to water in a water treatment plant is described. To a sample of the floc suspension polyacrylamide or similar filter aid chemicals are added, and the sample is then put through a fast filter. The resulting filtrate has the requisite properties for monitoring in an optical turbidimeter to control the automated system. (AEC)

  12. Applications of Text Analysis Tools for Spoken Response Grading

    ERIC Educational Resources Information Center

    Crossley, Scott; McNamara, Danielle

    2013-01-01

    This study explores the potential for automated indices related to speech delivery, language use, and topic development to model human judgments of TOEFL speaking proficiency in second language (L2) speech samples. For this study, 244 transcribed TOEFL speech samples taken from 244 L2 learners were analyzed using automated indices taken from…

  13. ATV ops

    NASA Image and Video Library

    2013-06-18

    ISS036-E-009246 (18 June 2013) --- NASA astronaut Chris Cassidy, Expedition 36 flight engineer, takes inventory of cargo in the European Space Agency's Automated Transfer Vehicle-4 (ATV-4) "Albert Einstein" currently docked to the Zvezda Service Module of the International Space Station.

  14. ATV Ingress

    NASA Image and Video Library

    2014-08-13

    ISS040-E-091979 (13 Aug. 2014) --- European Space Agency astronaut Alexander Gerst, Expedition 40 flight engineer, is pictured in the hatch after removing the docking mechanism of the newly-attached "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5) of the International Space Station.

  15. A Mobile Health Platform | NCI Technology Transfer Center | TTC

    Cancer.gov

    Researchers at the National Institute on Drug Abuse (NIDA) seek licensing or co-development of a mobile health technology that monitors and predicts a user’s psychological status in order to deliver an automated intervention when needed.

  16. Kuipers works with Stowage in ATV3

    NASA Image and Video Library

    2012-05-15

    ISS031-E-084591 (15 May 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 31 flight engineer, is pictured during cargo operations in ESA?s "Edoardo Amaldi" Automated Transfer Vehicle-3 (ATV-3) currently docked with the International Space Station.

  17. ATV Fly-Under

    NASA Image and Video Library

    2014-08-08

    ISS040-E-089829 (8 Aug. 2014) --- The “Georges Lemaitre” Automated Transfer Vehicle (ATV-5), photographed by an Expedition 40 crew member, flies directly under the International Space Station at a distance of about 3.7 miles to test sensors and radar systems designed for future European spacecraft. After its “fly-under” of the station, the ATV will move in front of, above, and behind the outpost for the final days of its two-week rendezvous that will lead to an automated docking to the aft port of the Zvezda Service Module on Aug. 12.

  18. ATV Fly-Under

    NASA Image and Video Library

    2014-08-08

    ISS040-E-089793 (8 Aug. 2014) --- The “Georges Lemaitre” Automated Transfer Vehicle (ATV-5), photographed by an Expedition 40 crew member, flies directly under the International Space Station at a distance of about 3.7 miles to test sensors and radar systems designed for future European spacecraft. After its “fly-under” of the station, the ATV will move in front of, above, and behind the outpost for the final days of its two-week rendezvous that will lead to an automated docking to the aft port of the Zvezda Service Module on Aug. 12.

  19. ATV Fly-Under

    NASA Image and Video Library

    2014-08-08

    ISS040-E-089802 (8 Aug. 2014) --- The “Georges Lemaitre” Automated Transfer Vehicle (ATV-5), photographed by an Expedition 40 crew member, flies directly under the International Space Station at a distance of about 3.7 miles to test sensors and radar systems designed for future European spacecraft. After its “fly-under” of the station, the ATV will move in front of, above, and behind the outpost for the final days of its two-week rendezvous that will lead to an automated docking to the aft port of the Zvezda Service Module on Aug. 12.

  20. ATV Fly-Under

    NASA Image and Video Library

    2014-08-08

    ISS040-E-089782 (8 Aug. 2014) --- The “Georges Lemaitre” Automated Transfer Vehicle (ATV-5), photographed by an Expedition 40 crew member, flies directly under the International Space Station at a distance of about 3.7 miles to test sensors and radar systems designed for future European spacecraft. After its “fly-under” of the station, the ATV will move in front of, above, and behind the outpost for the final days of its two-week rendezvous that will lead to an automated docking to the aft port of the Zvezda Service Module on Aug. 12.

  1. ATV Fly-Under

    NASA Image and Video Library

    2014-08-08

    ISS040-E-089830 (8 Aug. 2014) --- The “Georges Lemaitre” Automated Transfer Vehicle (ATV-5), photographed by an Expedition 40 crew member, flies directly under the International Space Station at a distance of about 3.7 miles to test sensors and radar systems designed for future European spacecraft. After its “fly-under” of the station, the ATV will move in front of, above, and behind the outpost for the final days of its two-week rendezvous that will lead to an automated docking to the aft port of the Zvezda Service Module on Aug. 12.

  2. ATV Fly-Under

    NASA Image and Video Library

    2014-08-08

    ISS040-E-089820 (8 Aug. 2014) --- The “Georges Lemaitre” Automated Transfer Vehicle (ATV-5), photographed by an Expedition 40 crew member, flies directly under the International Space Station at a distance of about 3.7 miles to test sensors and radar systems designed for future European spacecraft. After its “fly-under” of the station, the ATV will move in front of, above, and behind the outpost for the final days of its two-week rendezvous that will lead to an automated docking to the aft port of the Zvezda Service Module on Aug. 12.

  3. ATV Fly-Under

    NASA Image and Video Library

    2014-08-08

    ISS040-E-089798 (8 Aug. 2014) --- The “Georges Lemaitre” Automated Transfer Vehicle (ATV-5), photographed by an Expedition 40 crew member, flies directly under the International Space Station at a distance of about 3.7 miles to test sensors and radar systems designed for future European spacecraft. After its “fly-under” of the station, the ATV will move in front of, above, and behind the outpost for the final days of its two-week rendezvous that will lead to an automated docking to the aft port of the Zvezda Service Module on Aug. 12.

  4. Testing of a Microfluidic Sampling System for High Temperature Electrochemical MC&A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pereira, Candido; Nichols, Kevin

    2013-11-27

    This report describes the preliminary validation of a high-temperature microfluidic chip system for sampling of electrochemical process salt. Electroanalytical and spectroscopic techniques are attractive candidates for improvement through high-throughput sample analysis via miniaturization. Further, microfluidic chip systems are amenable to micro-scale chemical processing such as rapid, automated sample purification to improve sensor performance. The microfluidic chip was tested to determine the feasibility of the system for high temperature applications and conditions under which microfluidic systems can be used to generate salt droplets at process temperature to support development of material balance and control systems in a used fuel treatment facility.more » In FY13, the project focused on testing a quartz microchip device with molten salts at near process temperatures. The equipment was installed in glove box and tested up to 400°C using commercial thermal transfer fluids as the carrier phase. Preliminary tests were carried out with a low-melting halide salt to initially characterize the properties of this novel liquid-liquid system and to investigate the operating regimes for inducing droplet flow within candidate carrier fluids. Initial results show that the concept is viable for high temperature sampling but further development is required to optimize the system to operate with process relevant molten salts.« less

  5. Automated fluid analysis apparatus and techniques

    DOEpatents

    Szecsody, James E.

    2004-03-16

    An automated device that couples a pair of differently sized sample loops with a syringe pump and a source of degassed water. A fluid sample is mounted at an inlet port and delivered to the sample loops. A selected sample from the sample loops is diluted in the syringe pump with the degassed water and fed to a flow through detector for analysis. The sample inlet is also directly connected to the syringe pump to selectively perform analysis without dilution. The device is airtight and used to detect oxygen-sensitive species, such as dithionite in groundwater following a remedial injection to treat soil contamination.

  6. First evaluation of automated specimen inoculation for wound swab samples by use of the Previ Isola system compared to manual inoculation in a routine laboratory: finding a cost-effective and accurate approach.

    PubMed

    Mischnik, Alexander; Mieth, Markus; Busch, Cornelius J; Hofer, Stefan; Zimmermann, Stefan

    2012-08-01

    Automation of plate streaking is ongoing in clinical microbiological laboratories, but evaluation for routine use is mostly open. In the present study, the recovery of microorganisms from the Previ Isola system plated polyurethane (PU) swab samples is compared to manually plated control viscose swab samples from wounds according to the CLSI procedure M40-A (quality control of microbiological transport systems). One hundred twelve paired samples (224 swabs) were analyzed. In 80/112 samples (71%), concordant culture results were obtained with the two methods. In 32/112 samples (29%), CFU recovery of microorganisms from the two methods was discordant. In 24 (75%) of the 32 paired samples with a discordant result, Previ Isola plated PU swabs were superior. In 8 (25%) of the 32 paired samples with a discordant result, control viscose swabs were superior. The quality of colony growth on culture media for further investigations was superior with Previ Isola inoculated plates compared to manual plating techniques. Gram stain results were concordant between the two methods in 62/112 samples (55%). In 50/112 samples (45%), the results of Gram staining were discordant between the two methods. In 34 (68%) of the 50 paired samples with discordant results, Gram staining of PU swabs was superior to that of control viscose swabs. In 16 (32%) of the 50 paired samples, Gram staining of control viscose swabs was superior to that of PU swabs. We report the first clinical evaluation of Previ Isola automated specimen inoculation for wound swab samples. This study suggests that use of an automated specimen inoculation system has good results with regard to CFU recovery, quality of Gram staining, and accuracy of diagnosis.

  7. First Evaluation of Automated Specimen Inoculation for Wound Swab Samples by Use of the Previ Isola System Compared to Manual Inoculation in a Routine Laboratory: Finding a Cost-Effective and Accurate Approach

    PubMed Central

    Mieth, Markus; Busch, Cornelius J.; Hofer, Stefan; Zimmermann, Stefan

    2012-01-01

    Automation of plate streaking is ongoing in clinical microbiological laboratories, but evaluation for routine use is mostly open. In the present study, the recovery of microorganisms from the Previ Isola system plated polyurethane (PU) swab samples is compared to manually plated control viscose swab samples from wounds according to the CLSI procedure M40-A (quality control of microbiological transport systems). One hundred twelve paired samples (224 swabs) were analyzed. In 80/112 samples (71%), concordant culture results were obtained with the two methods. In 32/112 samples (29%), CFU recovery of microorganisms from the two methods was discordant. In 24 (75%) of the 32 paired samples with a discordant result, Previ Isola plated PU swabs were superior. In 8 (25%) of the 32 paired samples with a discordant result, control viscose swabs were superior. The quality of colony growth on culture media for further investigations was superior with Previ Isola inoculated plates compared to manual plating techniques. Gram stain results were concordant between the two methods in 62/112 samples (55%). In 50/112 samples (45%), the results of Gram staining were discordant between the two methods. In 34 (68%) of the 50 paired samples with discordant results, Gram staining of PU swabs was superior to that of control viscose swabs. In 16 (32%) of the 50 paired samples, Gram staining of control viscose swabs was superior to that of PU swabs. We report the first clinical evaluation of Previ Isola automated specimen inoculation for wound swab samples. This study suggests that use of an automated specimen inoculation system has good results with regard to CFU recovery, quality of Gram staining, and accuracy of diagnosis. PMID:22692745

  8. A method for automated control of belt velocity changes with an instrumented treadmill.

    PubMed

    Hinkel-Lipsker, Jacob W; Hahn, Michael E

    2016-01-04

    Increased practice difficulty during asymmetrical split-belt treadmill rehabilitation has been shown to improve gait outcomes during retention and transfer tests. However, research in this area has been limited by manual treadmill operation. In the case of variable practice, which requires stride-by-stride changes to treadmill belt velocities, the treadmill control must be automated. This paper presents a method for automation of asymmetrical split-belt treadmill walking, and evaluates how well this method performs with regards to timing of gait events. One participant walked asymmetrically for 100 strides, where the non-dominant limb was driven at their self-selected walking speed, while the other limb was driven randomly on a stride-by-stride basis. In the control loop, the key factors to insure that the treadmill belt had accelerated to its new velocity safely during the swing phase were the sampling rate of the A/D converter, processing time within the controller software, and acceleration of the treadmill belt. The combination of these three factors resulted in a total control loop time during each swing phase that satisfied these requirements with a factor of safety that was greater than 4. Further, a polynomial fit indicated that belt acceleration was the largest contributor to changes in this total time. This approach appears to be safe and reliable for stride-by-stride adjustment of treadmill belt speed, making it suitable for future asymmetrical split-belt walking studies. Further, it can be incorporated into virtual reality rehabilitation paradigms that utilize split-belt treadmill walking. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Automated Liquid Microjunction Surface Sampling-HPLC-MS/MS Analysis of Drugs and Metabolites in Whole-Body Thin Tissue Sections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kertesz, Vilmos; Van Berkel, Gary J

    A fully automated liquid extraction-based surface sampling system utilizing a commercially available autosampler coupled to high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) detection is reported. Discrete spots selected for droplet-based sampling and automated sample queue generation for both the autosampler and MS were enabled by using in-house developed software. In addition, co-registration of spatially resolved sampling position and HPLC-MS information to generate heatmaps of compounds monitored for subsequent data analysis was also available in the software. The system was evaluated with whole-body thin tissue sections from propranolol dosed rat. The hands-free operation of the system was demonstrated by creating heatmapsmore » of the parent drug and its hydroxypropranolol glucuronide metabolites with 1 mm resolution in the areas of interest. The sample throughput was approximately 5 min/sample defined by the time needed for chromatographic separation. The spatial distributions of both the drug and its metabolites were consistent with previous studies employing other liquid extraction-based surface sampling methodologies.« less

  10. RADIOLOGICAL SURVEY STATION DEVELOPMENT FOR THE PIT DISASSEMBLY AND CONVERSION PROJECT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dalmaso, M.; Gibbs, K.; Gregory, D.

    2011-05-22

    The Savannah River National Laboratory (SRNL) has developed prototype equipment to demonstrate remote surveying of Inner and Outer DOE Standard 3013 containers for fixed and transferable contamination in accordance with DOE Standard 3013 and 10 CFR 835 Appendix B. When fully developed the equipment will be part of a larger suite of equipment used to package material in accordance with DOE Standard 3013 at the Pit Disassembly and Conversion Project slated for installation at the Savannah River Site. The prototype system consists of a small six-axis industrial robot with an end effector consisting of a force sensor, vacuum gripper andmore » a three fingered pneumatic gripper. The work cell also contains two alpha survey instruments, swipes, swipe dispenser, and other ancillary equipment. An external controller interfaces with the robot controller, survey instruments and other ancillary equipment to control the overall process. SRNL is developing automated equipment for the Pit Disassembly and Conversion (PDC) Project that is slated for the Savannah River Site (SRS). The equipment being developed is automated packaging equipment for packaging plutonium bearing materials in accordance with DOE-STD-3013-2004. The subject of this paper is the development of a prototype Radiological Survey Station (RSS). Other automated equipment being developed for the PDC includes the Bagless transfer System, Outer Can Welder, Gantry Robot System (GRS) and Leak Test Station. The purpose of the RSS is to perform a frisk and swipe of the DOE Standard 3013 Container (either inner can or outer can) to check for fixed and transferable contamination. This is required to verify that the contamination levels are within the limits specified in DOE-STD-3013-2004 and 10 CFR 835, Appendix D. The surface contamination limit for the 3013 Outer Can (OC) is 500 dpm/100 cm2 (total) and 20 dpm/100 cm2 (transferable). This paper will concentrate on the RSS developments for the 3013 OC but the system for the 3013 Inner Can (IC) is nearly identical.« less

  11. Impact of collection container material and holding times on sample integrity for mercury and methylmercury in water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riscassi, Ami L; Miller, Carrie L; Brooks, Scott C

    Mercury (Hg) and methylmercury (MeHg) concentrations in streamwater can vary on short timescales (hourly or less) during storm flow and on a diel cycle; the frequency and timing of sampling required to accurately characterize these dynamics may be difficult to accomplish manually. Automated sampling can assist in sample collection; however use has been limited for Hg and MeHg analysis due to stability concerns of trace concentrations during extended storage times. We examined the viability of using automated samplers with disposable low-density polyethylene (LDPE) sample bags to collect industrially contaminated streamwater for unfiltered and filtered Hg and MeHg analysis. Specifically wemore » investigated the effect of holding times ranging from hours to days on streamwater collected during baseflow and storm flow. Unfiltered and filtered Hg and MeHg concentrations decreased with increases in time prior to sample processing; holding times of 24 hours or less resulted in concentration changes (mean 11 7% different) similar to variability in duplicates collected manually during analogous field conditions (mean 7 10% different). Comparisons of samples collected with manual and automated techniques throughout a year for a wide range of stream conditions were also found to be similar to differences observed between duplicate grab samples. These results demonstrate automated sampling into LDPE bags with holding times of 24 hours or less can be effectively used to collect streamwater for Hg and MeHg analysis, and encourage the testing of these materials and methods for implementation in other aqueous systems where high-frequency sampling is warranted.« less

  12. Moving Liquids with Sound: The Physics of Acoustic Droplet Ejection for Robust Laboratory Automation in Life Sciences.

    PubMed

    Hadimioglu, Babur; Stearns, Richard; Ellson, Richard

    2016-02-01

    Liquid handling instruments for life science applications based on droplet formation with focused acoustic energy or acoustic droplet ejection (ADE) were introduced commercially more than a decade ago. While the idea of "moving liquids with sound" was known in the 20th century, the development of precise methods for acoustic dispensing to aliquot life science materials in the laboratory began in earnest in the 21st century with the adaptation of the controlled "drop on demand" acoustic transfer of droplets from high-density microplates for high-throughput screening (HTS) applications. Robust ADE implementations for life science applications achieve excellent accuracy and precision by using acoustics first to sense the liquid characteristics relevant for its transfer, and then to actuate transfer of the liquid with customized application of sound energy to the given well and well fluid in the microplate. This article provides an overview of the physics behind ADE and its central role in both acoustical and rheological aspects of robust implementation of ADE in the life science laboratory and its broad range of ejectable materials. © 2015 Society for Laboratory Automation and Screening.

  13. Development and evaluation of a water level proportional water sampler

    NASA Astrophysics Data System (ADS)

    Schneider, P.; Lange, A.; Doppler, T.

    2013-12-01

    We developed and adapted a new type of sampler for time-integrated, water level proportional water quality sampling (e.g. nutrients, contaminants and stable isotopes). Our samplers are designed for sampling small to mid-size streams based on the law of Hagen-Poiseuille, where a capillary (or a valve) limits the sampling aliquot by reducing the air flux out of a submersed plastic (HDPE) sampling container. They are good alternatives to battery-operated automated water samplers when working in remote areas, or at streams that are characterized by pronounced daily discharge variations such as glacier streams. We evaluated our samplers against standard automated water samplers (ISCO 2900 and ISCO 6712) during the snowmelt in the Black Forest and the Alps and tested them in remote glacial catchments in Iceland, Switzerland and Kyrgyzstan. The results clearly showed that our samplers are an adequate tool for time-integrated, water level proportional water sampling at remote test sites, as they do not need batteries, are relatively inexpensive, lightweight, and compact. They are well suited for headwater streams - especially when sampling for stable isotopes - as the sampled water is perfectly protected against evaporation. Moreover, our samplers have a reduced risk of icing in cold environments, as they are installed submersed in water, whereas automated samplers (typically installed outside the stream) may get clogged due to icing of hoses. Based on this study, we find these samplers to be an adequate replacement for automated samplers when time-integrated sampling or solute load estimates are the main monitoring tasks.

  14. Compound Transfer by Acoustic Droplet Ejection Promotes Quality and Efficiency in Ultra-High-Throughput Screening Campaigns.

    PubMed

    Dawes, Timothy D; Turincio, Rebecca; Jones, Steven W; Rodriguez, Richard A; Gadiagellan, Dhireshan; Thana, Peter; Clark, Kevin R; Gustafson, Amy E; Orren, Linda; Liimatta, Marya; Gross, Daniel P; Maurer, Till; Beresini, Maureen H

    2016-02-01

    Acoustic droplet ejection (ADE) as a means of transferring library compounds has had a dramatic impact on the way in which high-throughput screening campaigns are conducted in many laboratories. Two Labcyte Echo ADE liquid handlers form the core of the compound transfer operation in our 1536-well based ultra-high-throughput screening (uHTS) system. Use of these instruments has promoted flexibility in compound formatting in addition to minimizing waste and eliminating compound carryover. We describe the use of ADE for the generation of assay-ready plates for primary screening as well as for follow-up dose-response evaluations. Custom software has enabled us to harness the information generated by the ADE instrumentation. Compound transfer via ADE also contributes to the screening process outside of the uHTS system. A second fully automated ADE-based system has been used to augment the capacity of the uHTS system as well as to permit efficient use of previously picked compound aliquots for secondary assay evaluations. Essential to the utility of ADE in the high-throughput screening process is the high quality of the resulting data. Examples of data generated at various stages of high-throughput screening campaigns are provided. Advantages and disadvantages of the use of ADE in high-throughput screening are discussed. © 2015 Society for Laboratory Automation and Screening.

  15. Comparison of visual and automated Deki Reader interpretation of malaria rapid diagnostic tests in rural Tanzanian military health facilities.

    PubMed

    Kalinga, Akili K; Mwanziva, Charles; Chiduo, Sarah; Mswanya, Christopher; Ishengoma, Deus I; Francis, Filbert; Temu, Lucky; Mahikwano, Lucas; Mgata, Saidi; Amoo, George; Anova, Lalaine; Wurrapa, Eyako; Zwingerman, Nora; Ferro, Santiago; Bhat, Geeta; Fine, Ian; Vesely, Brian; Waters, Norman; Kreishman-Deitrick, Mara; Hickman, Mark; Paris, Robert; Kamau, Edwin; Ohrt, Colin; Kavishe, Reginald A

    2018-05-29

    Although microscopy is a standard diagnostic tool for malaria and the gold standard, it is infrequently used because of unavailability of laboratory facilities and the absence of skilled readers in poor resource settings. Malaria rapid diagnostic tests (RDT) are currently used instead of or as an adjunct to microscopy. However, at very low parasitaemia (usually < 100 asexual parasites/µl), the test line on malaria rapid diagnostic tests can be faint and consequently hard to visualize and this may potentially affect the interpretation of the test results. Fio Corporation (Canada), developed an automated RDT reader named Deki Reader™ for automatic analysis and interpretation of rapid diagnostic tests. This study aimed to compare visual assessment and automated Deki Reader evaluations to interpret malaria rapid diagnostic tests against microscopy. Unlike in the previous studies where expert laboratory technicians interpreted the test results visually and operated the device, in this study low cadre health care workers who have not attended any formal professional training in laboratory sciences were employed. Finger prick blood from 1293 outpatients with fever was tested for malaria using RDT and Giemsa-stained microscopy for thick and thin blood smears. Blood samples for RDTs were processed according to manufacturers' instructions automated in the Deki Reader. Results of malaria diagnoses were compared between visual and the automated devise reading of RDT and microscopy. The sensitivity of malaria rapid diagnostic test results interpreted by the Deki Reader was 94.1% and that of visual interpretation was 93.9%. The specificity of malaria rapid diagnostic test results was 71.8% and that of human interpretation was 72.0%. The positive predictive value of malaria RDT results by the Deki Reader and visual interpretation was 75.8 and 75.4%, respectively, while the negative predictive values were 92.8 and 92.4%, respectively. The accuracy of RDT as interpreted by DR and visually was 82.6 and 82.1%, respectively. There was no significant difference in performance of RDTs interpreted by either automated DR or visually by unskilled health workers. However, despite the similarities in performance parameters, the device has proven useful because it provides stepwise guidance on processing RDT, data transfer and reporting.

  16. ATV ops

    NASA Image and Video Library

    2013-06-18

    ISS036-E-009256 (18 June 2013) --- NASA astronauts Chris Cassidy and Karen Nyberg, both Expedition 36 flight engineers, perform cargo operations in the European Space Agency's Automated Transfer Vehicle-4 (ATV-4) "Albert Einstein" currently docked to the Zvezda Service Module of the International Space Station.

  17. A Skills Approach to Career Development.

    ERIC Educational Resources Information Center

    Grites, Thomas J.

    1983-01-01

    A counseling approach encourages students' development of job-applicable, career-transferable skills to meet the changing demands of specialization, automation, mobility, urban growth, and industrial trends in the job market. These include writing; speaking; research; and analytical, organizational, leadership, interpersonal, and quantitative…

  18. Statistical Analysis Tools for Learning in Engineering Laboratories.

    ERIC Educational Resources Information Center

    Maher, Carolyn A.

    1990-01-01

    Described are engineering programs that have used automated data acquisition systems to implement data collection and analyze experiments. Applications include a biochemical engineering laboratory, heat transfer performance, engineering materials testing, mechanical system reliability, statistical control laboratory, thermo-fluid laboratory, and a…

  19. ATV 2 Approach

    NASA Image and Video Library

    2011-02-24

    ISS026-E-029470 (24 Feb. 2011) --- Surrounded by the blackness of space, the European Space Agency's "Johannes Kepler" Automated Transfer Vehicle-2 (ATV-2) approaches the International Space Station. Docking of the two spacecraft occurred at 10:59 a.m. (EST) on Feb. 24, 2011.

  20. Burbank works in the ATV-3

    NASA Image and Video Library

    2012-03-31

    ISS030-E-178667 (31 March 2012) --- NASA astronaut Dan Burbank, Expedition 30 commander, works in the newly attached European Space Agency?s ?Edoardo Amaldi? Automated Transfer Vehicle-3 (ATV-3). The ATV docked with the space station on March 28, 2012.

  1. Automation, robotics, and inflight training for manned Mars missions

    NASA Technical Reports Server (NTRS)

    Holt, Alan C.

    1986-01-01

    The automation, robotics, and inflight training requirements of manned Mars missions will be supported by similar capabilities developed for the space station program. Evolutionary space station onboard training facilities will allow the crewmembers to minimize the amount of training received on the ground by providing extensive onboard access to system and experiment malfunction procedures, maintenance procedures, repair procedures, and associated video sequences. Considerable on-the-job training will also be conducted for space station management, mobile remote manipulator operations, proximity operations with the Orbital Maneuvering Vehicle (and later the Orbit Transfer Vehicle), and telerobotics and mobile robots. A similar approach could be used for manned Mars mission training with significant additions such as high fidelity image generation and simulation systems such as holographic projection systems for Mars landing, ascent, and rendezvous training. In addition, a substantial increase in the use of automation and robotics for hazardous and tedious tasks would be expected for Mars mission. Mobile robots may be used to assist in the assembly, test and checkout of the Mars spacecraft, in the handling of nuclear components and hazardous chemical propellent transfer operations, in major spacecraft repair tasks which might be needed (repair of a micrometeroid penetration, for example), in the construction of a Mars base, and for routine maintenance of the base when unmanned.

  2. An automated system for global atmospheric sampling using B-747 airliners

    NASA Technical Reports Server (NTRS)

    Lew, K. Q.; Gustafsson, U. R. C.; Johnson, R. E.

    1981-01-01

    The global air sampling program utilizes commercial aircrafts in scheduled service to measure atmospheric constituents. A fully automated system designed for the 747 aircraft is described. Airline operational constraints and data and control subsystems are treated. The overall program management, system monitoring, and data retrieval from four aircraft in global service is described.

  3. Development of a Miniature Mass Spectrometer and an Automated Detector for Sampling Explosive Materials

    PubMed Central

    Hashimoto, Yuichiro

    2017-01-01

    The development of a robust ionization source using the counter-flow APCI, miniature mass spectrometer, and an automated sampling system for detecting explosives are described. These development efforts using mass spectrometry were made in order to improve the efficiencies of on-site detection in areas such as security, environmental, and industrial applications. A development team, including the author, has struggled for nearly 20 years to enhance the robustness and reduce the size of mass spectrometers to meet the requirements needed for on-site applications. This article focuses on the recent results related to the detection of explosive materials where automated particle sampling using a cyclone concentrator permitted the inspection time to be successfully reduced to 3 s. PMID:28337396

  4. Comparison of different methods to quantify fat classes in bakery products.

    PubMed

    Shin, Jae-Min; Hwang, Young-Ok; Tu, Ock-Ju; Jo, Han-Bin; Kim, Jung-Hun; Chae, Young-Zoo; Rhu, Kyung-Hun; Park, Seung-Kook

    2013-01-15

    The definition of fat differs in different countries; thus whether fat is listed on food labels depends on the country. Some countries list crude fat content in the 'Fat' section on the food label, whereas other countries list total fat. In this study, three methods were used for determining fat classes and content in bakery products: the Folch method, the automated Soxhlet method, and the AOAC 996.06 method. The results using these methods were compared. Fat (crude) extracted by the Folch and Soxhlet methods was gravimetrically determined and assessed by fat class using capillary gas chromatography (GC). In most samples, fat (total) content determined by the AOAC 996.06 method was lower than the fat (crude) content determined by the Folch or automated Soxhlet methods. Furthermore, monounsaturated fat or saturated fat content determined by the AOAC 996.06 method was lowest. Almost no difference was observed between fat (crude) content determined by the Folch method and that determined by the automated Soxhlet method for nearly all samples. In three samples (wheat biscuits, butter cookies-1, and chocolate chip cookies), monounsaturated fat, saturated fat, and trans fat content obtained by the automated Soxhlet method was higher than that obtained by the Folch method. The polyunsaturated fat content obtained by the automated Soxhlet method was not higher than that obtained by the Folch method in any sample. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. ABO Mistyping of cis-AB Blood Group by the Automated Microplate Technique.

    PubMed

    Chun, Sejong; Ryu, Mi Ra; Cha, Seung-Yeon; Seo, Ji-Young; Cho, Duck

    2018-01-01

    The cis -AB phenotype, although rare, is the relatively most frequent of ABO subgroups in Koreans. To prevent ABO mistyping of cis -AB samples, our hospital has applied a combination of the manual tile method with automated devices. Herein, we report cases of ABO mistyping detected by the combination testing system. Cases that showed discrepant results by automated devices and the manual tile method were evaluated. These samples were also tested by the standard tube method. The automated devices used in this study were a QWALYS-3 and Galileo NEO. Exons 6 and 7 of the ABO gene were sequenced. 13 cases that had the cis -AB allele showed results suggestive of the cis -AB subgroup by manual methods, but were interpreted as AB by either automated device. This happened in 87.5% of these cases by QWALYS-3 and 70.0% by Galileo NEO. Genotyping results showed that 12 cases were ABO*cis-AB01/ABO*O01 or ABO*cis-AB01/ABO*O02 , and one case was ABO*cis-AB01/ ABO*A102. Cis -AB samples were mistyped as AB by the automated microplate technique in some cases. We suggest that the manual tile method can be a simple supplemental test for the detection of the cis -AB phenotype, especially in countries with relatively high cis- AB prevalence.

  6. Autonomous Operations System: Development and Application

    NASA Technical Reports Server (NTRS)

    Toro Medina, Jaime A.; Wilkins, Kim N.; Walker, Mark; Stahl, Gerald M.

    2016-01-01

    Autonomous control systems provides the ability of self-governance beyond the conventional control system. As the complexity of mechanical and electrical systems increases, there develops a natural drive for developing robust control systems to manage complicated operations. By closing the bridge between conventional automated systems to knowledge based self-awareness systems, nominal control of operations can evolve into relying on safe critical mitigation processes to support any off-nominal behavior. Current research and development efforts lead by the Autonomous Propellant Loading (APL) group at NASA Kennedy Space Center aims to improve cryogenic propellant transfer operations by developing an automated control and health monitoring system. As an integrated systems, the center aims to produce an Autonomous Operations System (AOS) capable of integrating health management operations with automated control to produce a fully autonomous system.

  7. Automating Energy Bandgap Measurements in Semiconductors Using LabVIEW

    ERIC Educational Resources Information Center

    Garg, Amit; Sharma, Reena; Dhingra, Vishal

    2010-01-01

    In this paper, we report the development of an automated system for energy bandgap and resistivity measurement of a semiconductor sample using Four-Probe method for use in the undergraduate laboratory of Physics and Electronics students. The automated data acquisition and analysis system has been developed using National Instruments USB-6008 DAQ…

  8. Automated data collection based on RoboDiff at the ESRF beamline MASSIF-1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nurizzo, Didier, E-mail: Didier.nurizzo@esrf.fr; Guichard, Nicolas; McSweeney, Sean

    2016-07-27

    The European Synchrotron Radiation Facility has a long standing history in the automation of experiments in Macromolecular Crystallography. MASSIF-1 (Massively Automated Sample Screening and evaluation Integrated Facility), a beamline constructed as part of the ESRF Upgrade Phase I program, has been open to the external user community since July 2014 and offers a unique completely automated data collection service to both academic and industrial structural biologists.

  9. The LabTube - a novel microfluidic platform for assay automation in laboratory centrifuges.

    PubMed

    Kloke, A; Fiebach, A R; Zhang, S; Drechsel, L; Niekrawietz, S; Hoehl, M M; Kneusel, R; Panthel, K; Steigert, J; von Stetten, F; Zengerle, R; Paust, N

    2014-05-07

    Assay automation is the key for successful transformation of modern biotechnology into routine workflows. Yet, it requires considerable investment in processing devices and auxiliary infrastructure, which is not cost-efficient for laboratories with low or medium sample throughput or point-of-care testing. To close this gap, we present the LabTube platform, which is based on assay specific disposable cartridges for processing in laboratory centrifuges. LabTube cartridges comprise interfaces for sample loading and downstream applications and fluidic unit operations for release of prestored reagents, mixing, and solid phase extraction. Process control is achieved by a centrifugally-actuated ballpen mechanism. To demonstrate the workflow and functionality of the LabTube platform, we show two LabTube automated sample preparation assays from laboratory routines: DNA extractions from whole blood and purification of His-tagged proteins. Equal DNA and protein yields were observed compared to manual reference runs, while LabTube automation could significantly reduce the hands-on-time to one minute per extraction.

  10. An automated system for positive reinforcement training of group-housed macaque monkeys at breeding and research facilities.

    PubMed

    Tulip, Jennifer; Zimmermann, Jonas B; Farningham, David; Jackson, Andrew

    2017-06-15

    Behavioural training through positive reinforcement techniques is a well-recognised refinement to laboratory animal welfare. Behavioural neuroscience research requires subjects to be trained to perform repetitions of specific behaviours for food/fluid reward. Some animals fail to perform at a sufficient level, limiting the amount of data that can be collected and increasing the number of animals required for each study. We have implemented automated positive reinforcement training systems (comprising a button press task with variable levels of difficulty using LED cues and a fluid reward) at the breeding facility and research facility, to compare performance across these different settings, to pre-screen animals for selection and refine training protocols. Animals learned 1- and 4-choice button tasks within weeks of home enclosure training, with some inter-individual differences. High performance levels (∼200-300 trials per 60min session at ∼80% correct) were obtained without food or fluid restriction. Moreover, training quickly transferred to a laboratory version of the task. Animals that acquired the task at the breeding facility subsequently performed better both in early home enclosure sessions upon arrival at the research facility, and also in laboratory sessions. Automated systems at the breeding facility may be used to pre-screen animals for suitability for behavioural neuroscience research. In combination with conventional training, both the breeding and research facility systems facilitate acquisition and transference of learning. Automated systems have the potential to refine training protocols and minimise requirements for food/fluid control. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  11. AutoDrug: fully automated macromolecular crystallography workflows for fragment-based drug discovery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, Yingssu; Stanford University, 333 Campus Drive, Mudd Building, Stanford, CA 94305-5080; McPhillips, Scott E.

    New software has been developed for automating the experimental and data-processing stages of fragment-based drug discovery at a macromolecular crystallography beamline. A new workflow-automation framework orchestrates beamline-control and data-analysis software while organizing results from multiple samples. AutoDrug is software based upon the scientific workflow paradigm that integrates the Stanford Synchrotron Radiation Lightsource macromolecular crystallography beamlines and third-party processing software to automate the crystallography steps of the fragment-based drug-discovery process. AutoDrug screens a cassette of fragment-soaked crystals, selects crystals for data collection based on screening results and user-specified criteria and determines optimal data-collection strategies. It then collects and processes diffraction data,more » performs molecular replacement using provided models and detects electron density that is likely to arise from bound fragments. All processes are fully automated, i.e. are performed without user interaction or supervision. Samples can be screened in groups corresponding to particular proteins, crystal forms and/or soaking conditions. A single AutoDrug run is only limited by the capacity of the sample-storage dewar at the beamline: currently 288 samples. AutoDrug was developed in conjunction with RestFlow, a new scientific workflow-automation framework. RestFlow simplifies the design of AutoDrug by managing the flow of data and the organization of results and by orchestrating the execution of computational pipeline steps. It also simplifies the execution and interaction of third-party programs and the beamline-control system. Modeling AutoDrug as a scientific workflow enables multiple variants that meet the requirements of different user groups to be developed and supported. A workflow tailored to mimic the crystallography stages comprising the drug-discovery pipeline of CoCrystal Discovery Inc. has been deployed and successfully demonstrated. This workflow was run once on the same 96 samples that the group had examined manually and the workflow cycled successfully through all of the samples, collected data from the same samples that were selected manually and located the same peaks of unmodeled density in the resulting difference Fourier maps.« less

  12. Electrochemical pesticide detection with AutoDip--a portable platform for automation of crude sample analyses.

    PubMed

    Drechsel, Lisa; Schulz, Martin; von Stetten, Felix; Moldovan, Carmen; Zengerle, Roland; Paust, Nils

    2015-02-07

    Lab-on-a-chip devices hold promise for automation of complex workflows from sample to answer with minimal consumption of reagents in portable devices. However, complex, inhomogeneous samples as they occur in environmental or food analysis may block microchannels and thus often cause malfunction of the system. Here we present the novel AutoDip platform which is based on the movement of a solid phase through the reagents and sample instead of transporting a sequence of reagents through a fixed solid phase. A ball-pen mechanism operated by an external actuator automates unit operations such as incubation and washing by consecutively dipping the solid phase into the corresponding liquids. The platform is applied to electrochemical detection of organophosphorus pesticides in real food samples using an acetylcholinesterase (AChE) biosensor. Minimal sample preparation and an integrated reagent pre-storage module hold promise for easy handling of the assay. Detection of the pesticide chlorpyrifos-oxon (CPO) spiked into apple samples at concentrations of 10(-7) M has been demonstrated. This concentration is below the maximum residue level for chlorpyrifos in apples defined by the European Commission.

  13. Automated Verification of Spatial Resolution in Remotely Sensed Imagery

    NASA Technical Reports Server (NTRS)

    Davis, Bruce; Ryan, Robert; Holekamp, Kara; Vaughn, Ronald

    2011-01-01

    Image spatial resolution characteristics can vary widely among sources. In the case of aerial-based imaging systems, the image spatial resolution characteristics can even vary between acquisitions. In these systems, aircraft altitude, speed, and sensor look angle all affect image spatial resolution. Image spatial resolution needs to be verified with estimators that include the ground sample distance (GSD), the modulation transfer function (MTF), and the relative edge response (RER), all of which are key components of image quality, along with signal-to-noise ratio (SNR) and dynamic range. Knowledge of spatial resolution parameters is important to determine if features of interest are distinguishable in imagery or associated products, and to develop image restoration algorithms. An automated Spatial Resolution Verification Tool (SRVT) was developed to rapidly determine the spatial resolution characteristics of remotely sensed aerial and satellite imagery. Most current methods for assessing spatial resolution characteristics of imagery rely on pre-deployed engineered targets and are performed only at selected times within preselected scenes. The SRVT addresses these insufficiencies by finding uniform, high-contrast edges from urban scenes and then using these edges to determine standard estimators of spatial resolution, such as the MTF and the RER. The SRVT was developed using the MATLAB programming language and environment. This automated software algorithm assesses every image in an acquired data set, using edges found within each image, and in many cases eliminating the need for dedicated edge targets. The SRVT automatically identifies high-contrast, uniform edges and calculates the MTF and RER of each image, and when possible, within sections of an image, so that the variation of spatial resolution characteristics across the image can be analyzed. The automated algorithm is capable of quickly verifying the spatial resolution quality of all images within a data set, enabling the appropriate use of those images in a number of applications.

  14. Automated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting.

    PubMed

    Shayanfar, Noushin; Tobler, Ulrich; von Eckardstein, Arnold; Bestmann, Lukas

    2007-01-01

    Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. A total of 332 specimens were collected and analyzed for insoluble urine components by microscopy and automated analyzers, namely the Iris iQ200 (Iris Diagnostics) and the UF-100 flow cytometer (Sysmex). The coefficients of variation for day-to-day quality control of the iQ200 and UF-100 analyzers were 6.5% and 5.5%, respectively, for red blood cells. We reached accuracy ranging from 68% (bacteria) to 97% (yeast) for the iQ200 and from 42% (bacteria) to 93% (yeast) for the UF-100. The combination of dipstick and automated urine sediment analysis increased the sensitivity of screening to approximately 98%. We conclude that automated urine sediment analysis is sufficiently precise and improves the workflow in a routine laboratory. In addition, it allows sediment analysis of all urine samples and thereby helps to detect pathological samples that would have been missed in the conventional two-step procedure according to the European guidelines. Although it is not a substitute for microscopic sediment examination, it can, when combined with dipstick testing, reduce the number of specimens submitted to microscopy. Visual microscopy is still required for some samples, namely, dysmorphic erythrocytes, yeasts, Trichomonas, oval fat bodies, differentiation of casts and certain crystals.

  15. Piezoelectric MEMS resonators for monitoring grape must fermentation

    NASA Astrophysics Data System (ADS)

    Toledo, J.; Jiménez-Márquez, F.; Úbeda, J.; Ruiz-Díez, V.; Pfusterschmied, G.; Schmid, U.; Sánchez-Rojas, J. L.

    2016-10-01

    The traditional procedure followed by winemakers for monitoring grape must fermentation is not automated, has not enough accuracy or has only been tested in discrete must samples. In order to contribute to the automation and improvement of the wine fermentation process, we have designed an AlN-based piezoelectric microresonator, serving as a density sensor and being excited in the 4th-order roof tile-shaped vibration mode. Furthermore, conditioning circuits were designed to convert the one-port impedance of the resonator into a resonant two-port transfer function. This allowed us to design a Phase Locked Loop-based oscillator circuit, implemented with a commercial lock-in amplifier with an oscillation frequency determined by the vibrating mode. We were capable of measuring the fermentation kinetics by both tracking the resonance frequency and by determining the quality factor measurements of the microresonator. Moreover, the resonator was calibrated with an artificial model solution of grape must and then applied for the monitoring of real grape must fermentation. Our results demonstrate the high potential of MEMS resonators to detect the decrease in sugar and the increase in ethanol concentrations during the grape must fermentation with a resolution of 100 μg/ml and a sensitivity of 0.16 Hz/μg/ml as upper limits.

  16. The Stability and Validity of Automated Vocal Analysis in Preverbal Preschoolers With Autism Spectrum Disorder

    PubMed Central

    Woynaroski, Tiffany; Oller, D. Kimbrough; Keceli-Kaysili, Bahar; Xu, Dongxin; Richards, Jeffrey A.; Gilkerson, Jill; Gray, Sharmistha; Yoder, Paul

    2017-01-01

    Theory and research suggest that vocal development predicts “useful speech” in preschoolers with autism spectrum disorder (ASD), but conventional methods for measurement of vocal development are costly and time consuming. This longitudinal correlational study examines the reliability and validity of several automated indices of vocalization development relative to an index derived from human coded, conventional communication samples in a sample of preverbal preschoolers with ASD. Automated indices of vocal development were derived using software that is presently “in development” and/or only available for research purposes and using commercially available Language ENvironment Analysis (LENA) software. Indices of vocal development that could be derived using the software available for research purposes: (a) were highly stable with a single day-long audio recording, (b) predicted future spoken vocabulary to a degree that was nonsignificantly different from the index derived from conventional communication samples, and (c) continued to predict future spoken vocabulary even after controlling for concurrent vocabulary in our sample. The score derived from standard LENA software was similarly stable, but was not significantly correlated with future spoken vocabulary. Findings suggest that automated vocal analysis is a valid and reliable alternative to time intensive and expensive conventional communication samples for measurement of vocal development of preverbal preschoolers with ASD in research and clinical practice. PMID:27459107

  17. MODULAR ANALYTICS: A New Approach to Automation in the Clinical Laboratory.

    PubMed

    Horowitz, Gary L; Zaman, Zahur; Blanckaert, Norbert J C; Chan, Daniel W; Dubois, Jeffrey A; Golaz, Olivier; Mensi, Noury; Keller, Franz; Stolz, Herbert; Klingler, Karl; Marocchi, Alessandro; Prencipe, Lorenzo; McLawhon, Ronald W; Nilsen, Olaug L; Oellerich, Michael; Luthe, Hilmar; Orsonneau, Jean-Luc; Richeux, Gérard; Recio, Fernando; Roldan, Esther; Rymo, Lars; Wicktorsson, Anne-Charlotte; Welch, Shirley L; Wieland, Heinrich; Grawitz, Andrea Busse; Mitsumaki, Hiroshi; McGovern, Margaret; Ng, Katherine; Stockmann, Wolfgang

    2005-01-01

    MODULAR ANALYTICS (Roche Diagnostics) (MODULAR ANALYTICS, Elecsys and Cobas Integra are trademarks of a member of the Roche Group) represents a new approach to automation for the clinical chemistry laboratory. It consists of a control unit, a core unit with a bidirectional multitrack rack transportation system, and three distinct kinds of analytical modules: an ISE module, a P800 module (44 photometric tests, throughput of up to 800 tests/h), and a D2400 module (16 photometric tests, throughput up to 2400 tests/h). MODULAR ANALYTICS allows customised configurations for various laboratory workloads. The performance and practicability of MODULAR ANALYTICS were evaluated in an international multicentre study at 16 sites. Studies included precision, accuracy, analytical range, carry-over, and workflow assessment. More than 700 000 results were obtained during the course of the study. Median between-day CVs were typically less than 3% for clinical chemistries and less than 6% for homogeneous immunoassays. Median recoveries for nearly all standardised reference materials were within 5% of assigned values. Method comparisons versus current existing routine instrumentation were clinically acceptable in all cases. During the workflow studies, the work from three to four single workstations was transferred to MODULAR ANALYTICS, which offered over 100 possible methods, with reduction in sample splitting, handling errors, and turnaround time. Typical sample processing time on MODULAR ANALYTICS was less than 30 minutes, an improvement from the current laboratory systems. By combining multiple analytic units in flexible ways, MODULAR ANALYTICS met diverse laboratory needs and offered improvement in workflow over current laboratory situations. It increased overall efficiency while maintaining (or improving) quality.

  18. MODULAR ANALYTICS: A New Approach to Automation in the Clinical Laboratory

    PubMed Central

    Zaman, Zahur; Blanckaert, Norbert J. C.; Chan, Daniel W.; Dubois, Jeffrey A.; Golaz, Olivier; Mensi, Noury; Keller, Franz; Stolz, Herbert; Klingler, Karl; Marocchi, Alessandro; Prencipe, Lorenzo; McLawhon, Ronald W.; Nilsen, Olaug L.; Oellerich, Michael; Luthe, Hilmar; Orsonneau, Jean-Luc; Richeux, Gérard; Recio, Fernando; Roldan, Esther; Rymo, Lars; Wicktorsson, Anne-Charlotte; Welch, Shirley L.; Wieland, Heinrich; Grawitz, Andrea Busse; Mitsumaki, Hiroshi; McGovern, Margaret; Ng, Katherine; Stockmann, Wolfgang

    2005-01-01

    MODULAR ANALYTICS (Roche Diagnostics) (MODULAR ANALYTICS, Elecsys and Cobas Integra are trademarks of a member of the Roche Group) represents a new approach to automation for the clinical chemistry laboratory. It consists of a control unit, a core unit with a bidirectional multitrack rack transportation system, and three distinct kinds of analytical modules: an ISE module, a P800 module (44 photometric tests, throughput of up to 800 tests/h), and a D2400 module (16 photometric tests, throughput up to 2400 tests/h). MODULAR ANALYTICS allows customised configurations for various laboratory workloads. The performance and practicability of MODULAR ANALYTICS were evaluated in an international multicentre study at 16 sites. Studies included precision, accuracy, analytical range, carry-over, and workflow assessment. More than 700 000 results were obtained during the course of the study. Median between-day CVs were typically less than 3% for clinical chemistries and less than 6% for homogeneous immunoassays. Median recoveries for nearly all standardised reference materials were within 5% of assigned values. Method comparisons versus current existing routine instrumentation were clinically acceptable in all cases. During the workflow studies, the work from three to four single workstations was transferred to MODULAR ANALYTICS, which offered over 100 possible methods, with reduction in sample splitting, handling errors, and turnaround time. Typical sample processing time on MODULAR ANALYTICS was less than 30 minutes, an improvement from the current laboratory systems. By combining multiple analytic units in flexible ways, MODULAR ANALYTICS met diverse laboratory needs and offered improvement in workflow over current laboratory situations. It increased overall efficiency while maintaining (or improving) quality. PMID:18924721

  19. First Biogenic VOC Flux Results from the UCI Fluxtron Plant Chamber Facility

    NASA Astrophysics Data System (ADS)

    Seco, R.; Gu, D.; Joo, E.; Nagalingam, S.; Aristizabal, B. H.; Basu, C.; Kim, S.; Guenther, A. B.

    2017-12-01

    Atmospheric biogenic volatile organic compounds (BVOCs) have key environmental, ecological and biological roles, and can influence atmospheric chemistry, secondary aerosol formation, and regional climate. Quantifying BVOC emission rates and their impact on atmospheric chemistry is one of the greatest challenges with respect to predicting future air pollution in the context of a changing climate. A new facility, the UCI Fluxtron, has been developed at the Department of Earth System Science at the University of California Irvine to study the response of BVOC emissions to extreme weather and pollution stress. The UCI Fluxtron is designed for automated, continuous measurement of plant physiology and multi-modal BVOC chemical analysis from multiple plants. It consists of two controlled-environment walk-in growth chambers that contain several plant enclosures, a gas make-up system to precisely control the composition (e.g., H2O, CO2, O3 and VOC concentrations) of the air entering each enclosure. A sample manifold with automated inlet switching is used for measurements with in-situ and real-time VOC analysis instruments: H2O, CO2 fluxes can be measured continually with an infrared gas analyzer (IRGA) and BVOCs with a proton transfer reaction -time of flight- mass spectrometer (PTR-TOF-MS). Offline samples can also be taken via adsorbent cartridges to be analyzed in a thermal desorption gas chromatograph coupled to a TOF-MS detector. We present the first results of H2O, CO2 and BVOC fluxes, including the characterization and testing of the Fluxtron system. For example, measurements of young dragon tree (Paulownia elongata) individuals using whole-plant enclosures.

  20. A High-Resolution Minimicroscope System for Wireless Real-Time Monitoring.

    PubMed

    Wang, Zongjie; Boddeda, Akash; Parker, Benjamin; Samanipour, Roya; Ghosh, Sanjoy; Menard, Frederic; Kim, Keekyoung

    2018-07-01

    Compact, cost-effective, and high-performance microscope that enables the real-time imaging of cells and lab-on-a-chip devices is highly demanded for cell biology and biomedical engineering. This paper aims to present the design and application of an inexpensive wireless minimicroscope with resolution up to 2592 × 1944 pixels and speed up to 90 f/s. The minimicroscope system was built on a commercial embedded system (Raspberry Pi). We modified a camera module and adopted an inverse dual lens system to obtain the clear field of view and appropriate magnification for tens of micrometer objects. The system was capable of capturing time-lapse images and transferring image data wirelessly. The entire system can be operated wirelessly and cordlessly in a conventional cell culturing incubator. The developed minimicroscope was used to monitor the attachment and proliferation of NIH-3T3 and HEK 293 cells inside an incubator for 50 h. In addition, the minimicroscope was used to monitor a droplet generation process in a microfluidic device. The high-quality images captured by the minimicroscope enabled us an automated analysis of experimental parameters. The successful applications prove the great potential of the developed minimicroscope for monitoring various biological samples and microfluidic devices. This paper presents the design of a high-resolution minimicroscope system that enables the wireless real-time imaging of cells inside the incubator. This system has been verified to be a useful tool to obtain high-quality images and videos for the automated quantitative analysis of biological samples and lab-on-a-chip devices in the long term.

  1. An anatomy of industrial robots and their controls

    NASA Astrophysics Data System (ADS)

    Luh, J. Y. S.

    1983-02-01

    The modernization of manufacturing facilities by means of automation represents an approach for increasing productivity in industry. The three existing types of automation are related to continuous process controls, the use of transfer conveyor methods, and the employment of programmable automation for the low-volume batch production of discrete parts. The industrial robots, which are defined as computer controlled mechanics manipulators, belong to the area of programmable automation. Typically, the robots perform tasks of arc welding, paint spraying, or foundary operation. One may assign a robot to perform a variety of job assignments simply by changing the appropriate computer program. The present investigation is concerned with an evaluation of the potential of the robot on the basis of its basic structure and controls. It is found that robots function well in limited areas of industry. If the range of tasks which robots can perform is to be expanded, it is necessary to provide multiple-task sensors, or special tooling, or even automatic tooling.

  2. Wireless energizing system for an automated implantable sensor.

    PubMed

    Swain, Biswaranjan; Nayak, Praveen P; Kar, Durga P; Bhuyan, Satyanarayan; Mishra, Laxmi P

    2016-07-01

    The wireless drive of an automated implantable electronic sensor has been explored for health monitoring applications. The proposed system comprises of an automated biomedical sensing system which is energized through resonant inductive coupling. The implantable sensor unit is able to monitor the body temperature parameter and sends back the corresponding telemetry data wirelessly to the data recoding unit. It has been observed that the wireless power delivery system is capable of energizing the automated biomedical implantable electronic sensor placed over a distance of 3 cm from the power transmitter with an energy transfer efficiency of 26% at the operating resonant frequency of 562 kHz. This proposed method ensures real-time monitoring of different human body temperatures around the clock. The monitored temperature data have been compared with a calibrated temperature measurement system to ascertain the accuracy of the proposed system. The investigated technique can also be useful for monitoring other body parameters such as blood pressure, bladder pressure, and physiological signals of the patient in vivo using various implantable sensors.

  3. Automated position control of a surface array relative to a liquid microjunction surface sampler

    DOEpatents

    Van Berkel, Gary J.; Kertesz, Vilmos; Ford, Michael James

    2007-11-13

    A system and method utilizes an image analysis approach for controlling the probe-to-surface distance of a liquid junction-based surface sampling system for use with mass spectrometric detection. Such an approach enables a hands-free formation of the liquid microjunction used to sample solution composition from the surface and for re-optimization, as necessary, of the microjunction thickness during a surface scan to achieve a fully automated surface sampling system.

  4. Automation of TL brick dating by ADAM-1

    NASA Astrophysics Data System (ADS)

    Čechák, T.; Gerndt, J.; Hiršl, P.; Jiroušek, P.; Kanaval, J.; Kubelík, M.; Musílek, L.

    2001-06-01

    A specially adapted machine ADAM-1 for the thermoluminescence fine grain dating of bricks was constructed in an interdisciplinary research project, undertaken by a team recruited from three faculties of the Czech Technical University in Prague. This TL-reader is able to measure and evaluate automatically numerous samples. The sample holder has 60 sample positions, which allow the irradiation and evaluation of samples taken from two locations. All procedures of alpha and beta irradiation by varying doses and the TL-signal measurement as also the age evaluation and error assessment are programmable and fully automated.

  5. Automation of dimethylation after guanidination labeling chemistry and its compatibility with common buffers and surfactants for mass spectrometry-based shotgun quantitative proteome analysis.

    PubMed

    Lo, Andy; Tang, Yanan; Chen, Lu; Li, Liang

    2013-07-25

    Isotope labeling liquid chromatography-mass spectrometry (LC-MS) is a major analytical platform for quantitative proteome analysis. Incorporation of isotopes used to distinguish samples plays a critical role in the success of this strategy. In this work, we optimized and automated a chemical derivatization protocol (dimethylation after guanidination, 2MEGA) to increase the labeling reproducibility and reduce human intervention. We also evaluated the reagent compatibility of this protocol to handle biological samples in different types of buffers and surfactants. A commercially available liquid handler was used for reagent dispensation to minimize analyst intervention and at least twenty protein digest samples could be prepared in a single run. Different front-end sample preparation methods for protein solubilization (SDS, urea, Rapigest™, and ProteaseMAX™) and two commercially available cell lysis buffers were evaluated for compatibility with the automated protocol. It was found that better than 94% desired labeling could be obtained in all conditions studied except urea, where the rate was reduced to about 92% due to carbamylation on the peptide amines. This work illustrates the automated 2MEGA labeling process can be used to handle a wide range of protein samples containing various reagents that are often encountered in protein sample preparation for quantitative proteome analysis. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Clinical Chemistry Laboratory Automation in the 21st Century - Amat Victoria curam (Victory loves careful preparation)

    PubMed Central

    Armbruster, David A; Overcash, David R; Reyes, Jaime

    2014-01-01

    The era of automation arrived with the introduction of the AutoAnalyzer using continuous flow analysis and the Robot Chemist that automated the traditional manual analytical steps. Successive generations of stand-alone analysers increased analytical speed, offered the ability to test high volumes of patient specimens, and provided large assay menus. A dichotomy developed, with a group of analysers devoted to performing routine clinical chemistry tests and another group dedicated to performing immunoassays using a variety of methodologies. Development of integrated systems greatly improved the analytical phase of clinical laboratory testing and further automation was developed for pre-analytical procedures, such as sample identification, sorting, and centrifugation, and post-analytical procedures, such as specimen storage and archiving. All phases of testing were ultimately combined in total laboratory automation (TLA) through which all modules involved are physically linked by some kind of track system, moving samples through the process from beginning-to-end. A newer and very powerful, analytical methodology is liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS). LC-MS/MS has been automated but a future automation challenge will be to incorporate LC-MS/MS into TLA configurations. Another important facet of automation is informatics, including middleware, which interfaces the analyser software to a laboratory information systems (LIS) and/or hospital information systems (HIS). This software includes control of the overall operation of a TLA configuration and combines analytical results with patient demographic information to provide additional clinically useful information. This review describes automation relevant to clinical chemistry, but it must be recognised that automation applies to other specialties in the laboratory, e.g. haematology, urinalysis, microbiology. It is a given that automation will continue to evolve in the clinical laboratory, limited only by the imagination and ingenuity of laboratory scientists. PMID:25336760

  7. Clinical Chemistry Laboratory Automation in the 21st Century - Amat Victoria curam (Victory loves careful preparation).

    PubMed

    Armbruster, David A; Overcash, David R; Reyes, Jaime

    2014-08-01

    The era of automation arrived with the introduction of the AutoAnalyzer using continuous flow analysis and the Robot Chemist that automated the traditional manual analytical steps. Successive generations of stand-alone analysers increased analytical speed, offered the ability to test high volumes of patient specimens, and provided large assay menus. A dichotomy developed, with a group of analysers devoted to performing routine clinical chemistry tests and another group dedicated to performing immunoassays using a variety of methodologies. Development of integrated systems greatly improved the analytical phase of clinical laboratory testing and further automation was developed for pre-analytical procedures, such as sample identification, sorting, and centrifugation, and post-analytical procedures, such as specimen storage and archiving. All phases of testing were ultimately combined in total laboratory automation (TLA) through which all modules involved are physically linked by some kind of track system, moving samples through the process from beginning-to-end. A newer and very powerful, analytical methodology is liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS). LC-MS/MS has been automated but a future automation challenge will be to incorporate LC-MS/MS into TLA configurations. Another important facet of automation is informatics, including middleware, which interfaces the analyser software to a laboratory information systems (LIS) and/or hospital information systems (HIS). This software includes control of the overall operation of a TLA configuration and combines analytical results with patient demographic information to provide additional clinically useful information. This review describes automation relevant to clinical chemistry, but it must be recognised that automation applies to other specialties in the laboratory, e.g. haematology, urinalysis, microbiology. It is a given that automation will continue to evolve in the clinical laboratory, limited only by the imagination and ingenuity of laboratory scientists.

  8. Automated fault-management in a simulated spaceflight micro-world

    NASA Technical Reports Server (NTRS)

    Lorenz, Bernd; Di Nocera, Francesco; Rottger, Stefan; Parasuraman, Raja

    2002-01-01

    BACKGROUND: As human spaceflight missions extend in duration and distance from Earth, a self-sufficient crew will bear far greater onboard responsibility and authority for mission success. This will increase the need for automated fault management (FM). Human factors issues in the use of such systems include maintenance of cognitive skill, situational awareness (SA), trust in automation, and workload. This study examine the human performance consequences of operator use of intelligent FM support in interaction with an autonomous, space-related, atmospheric control system. METHODS: An expert system representing a model-base reasoning agent supported operators at a low level of automation (LOA) by a computerized fault finding guide, at a medium LOA by an automated diagnosis and recovery advisory, and at a high LOA by automate diagnosis and recovery implementation, subject to operator approval or veto. Ten percent of the experimental trials involved complete failure of FM support. RESULTS: Benefits of automation were reflected in more accurate diagnoses, shorter fault identification time, and reduced subjective operator workload. Unexpectedly, fault identification times deteriorated more at the medium than at the high LOA during automation failure. Analyses of information sampling behavior showed that offloading operators from recovery implementation during reliable automation enabled operators at high LOA to engage in fault assessment activities CONCLUSIONS: The potential threat to SA imposed by high-level automation, in which decision advisories are automatically generated, need not inevitably be counteracted by choosing a lower LOA. Instead, freeing operator cognitive resources by automatic implementation of recover plans at a higher LOA can promote better fault comprehension, so long as the automation interface is designed to support efficient information sampling.

  9. ESA Albert Einstein ATV-4 during approach

    NASA Image and Video Library

    2013-06-15

    ISS036-E-007747 (15 June 2013) --- The European Space Agency's Automated Transfer Vehicle-4 (ATV-4) “Albert Einstein” is about to dock to the orbital outpost at 2:07 GMT, June 15, 2013, following a ten-day period of free-flight.

  10. ESA Albert Einstein ATV-4 during approach

    NASA Image and Video Library

    2013-06-15

    ISS036-E-007862 (15 June 2013) --- The European Space Agency's Automated Transfer Vehicle-4 (ATV-4) “Albert Einstein” is about to dock to the orbital outpost at 2:07 GMT, June 15, 2013, following a ten-day period of free-flight.

  11. ESA Albert Einstein ATV-4 during approach

    NASA Image and Video Library

    2013-06-15

    ISS036-E-007859 (15 June 2013) --- The European Space Agency's Automated Transfer Vehicle-4 (ATV-4) “Albert Einstein” is about to dock to the orbital outpost at 2:07 GMT, June 15, 2013, following a ten-day period of free-flight.

  12. ESA Albert Einstein ATV-4 during approach

    NASA Image and Video Library

    2013-06-15

    ISS036-E-007748 (15 June 2013) --- The European Space Agency's Automated Transfer Vehicle-4 (ATV-4) “Albert Einstein” is about to dock to the orbital outpost at 2:07 GMT, June 15, 2013, following a ten-day period of free-flight.

  13. Design Language for Digital Systems

    NASA Technical Reports Server (NTRS)

    Shiva, S. G.

    1985-01-01

    Digital Systems Design Language (DDL) is convenient hardware description language for developing and testing digital designs and for inputting design details into design automation system. Describes digital systems at gate, register transfer, and combinational block levels. DDL-based programs written in FORTRAN IV for batch execution.

  14. ATV 2 Approach

    NASA Image and Video Library

    2011-02-24

    ISS026-E-029435 (24 Feb. 2011) --- Backdropped by a cloud-covered part of Earth, the European Space Agency's "Johannes Kepler" Automated Transfer Vehicle-2 (ATV-2) approaches the International Space Station. Docking of the two spacecraft occurred at 10:59 a.m. (EST) on Feb. 24, 2011.

  15. View of FE Samokutyaev during ATV Undocking Preparations

    NASA Image and Video Library

    2011-06-19

    ISS028-E-007784 (19 June 2011) --- Russian cosmonaut Alexander Samokutyaev, Expedition 28 flight engineer, works in the European Space Agency's "Johannes Kepler" Automated Transfer Vehicle-2 (ATV-2) during preparations for the undocking of the ATV2 from the International Space Station.

  16. jsc2013e090894

    NASA Image and Video Library

    2013-10-28

    Photographic coverage of Expedition 37 flight controllers on console with Flight Director's Jerry Jason and Tony Ceccacci during the undocking of Europe's 4th Automated Transfer Vehicle (ATV) from the International Space Station. Photo Date: October 28, 2013. Location: Building 30 - FCR1. Photographer: Robert Markowitz

  17. jsc2013e090912

    NASA Image and Video Library

    2013-10-28

    Photographic coverage of Expedition 37 flight controllers on console with Flight Director's Jerry Jason and Tony Ceccacci during the undocking of Europe's 4th Automated Transfer Vehicle (ATV) from the International Space Station. Photo Date: October 28, 2013. Location: Building 30 - FCR1. Photographer: Robert Markowitz

  18. jsc2013e090914

    NASA Image and Video Library

    2013-10-28

    Photographic coverage of Expedition 37 flight controllers on console with Flight Director's Jerry Jason and Tony Ceccacci during the undocking of Europe's 4th Automated Transfer Vehicle (ATV) from the International Space Station. Photo Date: October 28, 2013. Location: Building 30 - FCR1. Photographer: Robert Markowitz

  19. jsc2013e090898

    NASA Image and Video Library

    2013-10-28

    Photographic coverage of Expedition 37 flight controllers on console with Flight Director's Jerry Jason and Tony Ceccacci during the undocking of Europe's 4th Automated Transfer Vehicle (ATV) from the International Space Station. Photo Date: October 28, 2013. Location: Building 30 - FCR1. Photographer: Robert Markowitz

  20. jsc2013e090910

    NASA Image and Video Library

    2013-10-28

    Photographic coverage of Expedition 37 flight controllers on console with Flight Director's Jerry Jason and Tony Ceccacci during the undocking of Europe's 4th Automated Transfer Vehicle (ATV) from the International Space Station. Photo Date: October 28, 2013. Location: Building 30 - FCR1. Photographer: Robert Markowitz

  1. jsc2013e090913

    NASA Image and Video Library

    2013-10-28

    Photographic coverage of Expedition 37 flight controllers on console with Flight Director's Jerry Jason and Tony Ceccacci during the undocking of Europe's 4th Automated Transfer Vehicle (ATV) from the International Space Station. Photo Date: October 28, 2013. Location: Building 30 - FCR1. Photographer: Robert Markowitz

  2. Automated cellular sample preparation using a Centrifuge-on-a-Chip.

    PubMed

    Mach, Albert J; Kim, Jae Hyun; Arshi, Armin; Hur, Soojung Claire; Di Carlo, Dino

    2011-09-07

    The standard centrifuge is a laboratory instrument widely used by biologists and medical technicians for preparing cell samples. Efforts to automate the operations of concentration, cell separation, and solution exchange that a centrifuge performs in a simpler and smaller platform have had limited success. Here, we present a microfluidic chip that replicates the functions of a centrifuge without moving parts or external forces. The device operates using a purely fluid dynamic phenomenon in which cells selectively enter and are maintained in microscale vortices. Continuous and sequential operation allows enrichment of cancer cells from spiked blood samples at the mL min(-1) scale, followed by fluorescent labeling of intra- and extra-cellular antigens on the cells without the need for manual pipetting and washing steps. A versatile centrifuge-analogue may open opportunities in automated, low-cost and high-throughput sample preparation as an alternative to the standard benchtop centrifuge in standardized clinical diagnostics or resource poor settings.

  3. Automation system for neutron activation analysis at the reactor IBR-2, Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, Dubna, Russia.

    PubMed

    Pavlov, Sergey S; Dmitriev, Andrey Yu; Frontasyeva, Marina V

    The present status of development of software packages and equipment designed for automation of NAA at the reactor IBR-2 of FLNP, JINR, Dubna, RF, is described. The NAA database, construction of sample changers and software for automation of spectra measurement and calculation of concentrations are presented. Automation of QC procedures is integrated in the software developed. Details of the design are shown.

  4. Automated Sample Preparation for Radiogenic and Non-Traditional Metal Isotopes: Removing an Analytical Barrier for High Sample Throughput

    NASA Astrophysics Data System (ADS)

    Field, M. Paul; Romaniello, Stephen; Gordon, Gwyneth W.; Anbar, Ariel D.; Herrmann, Achim; Martinez-Boti, Miguel A.; Anagnostou, Eleni; Foster, Gavin L.

    2014-05-01

    MC-ICP-MS has dramatically improved the analytical throughput for high-precision radiogenic and non-traditional isotope ratio measurements, compared to TIMS. The generation of large data sets, however, remains hampered by tedious manual drip chromatography required for sample purification. A new, automated chromatography system reduces the laboratory bottle neck and expands the utility of high-precision isotope analyses in applications where large data sets are required: geochemistry, forensic anthropology, nuclear forensics, medical research and food authentication. We have developed protocols to automate ion exchange purification for several isotopic systems (B, Ca, Fe, Cu, Zn, Sr, Cd, Pb and U) using the new prepFAST-MC™ (ESI, Nebraska, Omaha). The system is not only inert (all-flouropolymer flow paths), but is also very flexible and can easily facilitate different resins, samples, and reagent types. When programmed, precise and accurate user defined volumes and flow rates are implemented to automatically load samples, wash the column, condition the column and elute fractions. Unattended, the automated, low-pressure ion exchange chromatography system can process up to 60 samples overnight. Excellent reproducibility, reliability, recovery, with low blank and carry over for samples in a variety of different matrices, have been demonstrated to give accurate and precise isotopic ratios within analytical error for several isotopic systems (B, Ca, Fe, Cu, Zn, Sr, Cd, Pb and U). This illustrates the potential of the new prepFAST-MC™ (ESI, Nebraska, Omaha) as a powerful tool in radiogenic and non-traditional isotope research.

  5. Automation of diagnostic genetic testing: mutation detection by cyclic minisequencing.

    PubMed

    Alagrund, Katariina; Orpana, Arto K

    2014-01-01

    The rising role of nucleic acid testing in clinical decision making is creating a need for efficient and automated diagnostic nucleic acid test platforms. Clinical use of nucleic acid testing sets demands for shorter turnaround times (TATs), lower production costs and robust, reliable methods that can easily adopt new test panels and is able to run rare tests in random access principle. Here we present a novel home-brew laboratory automation platform for diagnostic mutation testing. This platform is based on the cyclic minisequecing (cMS) and two color near-infrared (NIR) detection. Pipetting is automated using Tecan Freedom EVO pipetting robots and all assays are performed in 384-well micro plate format. The automation platform includes a data processing system, controlling all procedures, and automated patient result reporting to the hospital information system. We have found automated cMS a reliable, inexpensive and robust method for nucleic acid testing for a wide variety of diagnostic tests. The platform is currently in clinical use for over 80 mutations or polymorphisms. Additionally to tests performed from blood samples, the system performs also epigenetic test for the methylation of the MGMT gene promoter, and companion diagnostic tests for analysis of KRAS and BRAF gene mutations from formalin fixed and paraffin embedded tumor samples. Automation of genetic test reporting is found reliable and efficient decreasing the work load of academic personnel.

  6. An Automated Sample Processing System for Planetary Exploration

    NASA Technical Reports Server (NTRS)

    Soto, Juancarlos; Lasnik, James; Roark, Shane; Beegle, Luther

    2012-01-01

    An Automated Sample Processing System (ASPS) for wet chemistry processing of organic materials on the surface of Mars has been jointly developed by Ball Aerospace and the Jet Propulsion Laboratory. The mechanism has been built and tested to demonstrate TRL level 4. This paper describes the function of the system, mechanism design, lessons learned, and several challenges that were overcome.

  7. Re-Emergence of Under-Selected Stimuli, after the Extinction of Over-Selected Stimuli in an Automated Match to Samples Procedure

    ERIC Educational Resources Information Center

    Broomfield, Laura; McHugh, Louise; Reed, Phil

    2008-01-01

    Stimulus over-selectivity occurs when one of potentially many aspects of the environment comes to control behaviour. In two experiments, adults with no developmental disabilities, were trained and tested in an automated match to samples (MTS) paradigm. In Experiment 1, participants completed two conditions, in one of which the over-selected…

  8. Evaluation of computer-based computer tomography stratification against outcome models in connective tissue disease-related interstitial lung disease: a patient outcome study.

    PubMed

    Jacob, Joseph; Bartholmai, Brian J; Rajagopalan, Srinivasan; Brun, Anne Laure; Egashira, Ryoko; Karwoski, Ronald; Kokosi, Maria; Wells, Athol U; Hansell, David M

    2016-11-23

    To evaluate computer-based computer tomography (CT) analysis (CALIPER) against visual CT scoring and pulmonary function tests (PFTs) when predicting mortality in patients with connective tissue disease-related interstitial lung disease (CTD-ILD). To identify outcome differences between distinct CTD-ILD groups derived following automated stratification of CALIPER variables. A total of 203 consecutive patients with assorted CTD-ILDs had CT parenchymal patterns evaluated by CALIPER and visual CT scoring: honeycombing, reticular pattern, ground glass opacities, pulmonary vessel volume, emphysema, and traction bronchiectasis. CT scores were evaluated against pulmonary function tests: forced vital capacity, diffusing capacity for carbon monoxide, carbon monoxide transfer coefficient, and composite physiologic index for mortality analysis. Automated stratification of CALIPER-CT variables was evaluated in place of and alongside forced vital capacity and diffusing capacity for carbon monoxide in the ILD gender, age physiology (ILD-GAP) model using receiver operating characteristic curve analysis. Cox regression analyses identified four independent predictors of mortality: patient age (P < 0.0001), smoking history (P = 0.0003), carbon monoxide transfer coefficient (P = 0.003), and pulmonary vessel volume (P < 0.0001). Automated stratification of CALIPER variables identified three morphologically distinct groups which were stronger predictors of mortality than all CT and functional indices. The Stratified-CT model substituted automated stratified groups for functional indices in the ILD-GAP model and maintained model strength (area under curve (AUC) = 0.74, P < 0.0001), ILD-GAP (AUC = 0.72, P < 0.0001). Combining automated stratified groups with the ILD-GAP model (stratified CT-GAP model) strengthened predictions of 1- and 2-year mortality: ILD-GAP (AUC = 0.87 and 0.86, respectively); stratified CT-GAP (AUC = 0.89 and 0.88, respectively). CALIPER-derived pulmonary vessel volume is an independent predictor of mortality across all CTD-ILD patients. Furthermore, automated stratification of CALIPER CT variables represents a novel method of prognostication at least as robust as PFTs in CTD-ILD patients.

  9. Fully Automated Data Collection Using PAM and the Development of PAM/SPACE Reversible Cassettes

    NASA Astrophysics Data System (ADS)

    Hiraki, Masahiko; Watanabe, Shokei; Chavas, Leonard M. G.; Yamada, Yusuke; Matsugaki, Naohiro; Igarashi, Noriyuki; Wakatsuki, Soichi; Fujihashi, Masahiro; Miki, Kunio; Baba, Seiki; Ueno, Go; Yamamoto, Masaki; Suzuki, Mamoru; Nakagawa, Atsushi; Watanabe, Nobuhisa; Tanaka, Isao

    2010-06-01

    To remotely control and automatically collect data in high-throughput X-ray data collection experiments, the Structural Biology Research Center at the Photon Factory (PF) developed and installed sample exchange robots PAM (PF Automated Mounting system) at PF macromolecular crystallography beamlines; BL-5A, BL-17A, AR-NW12A and AR-NE3A. We developed and installed software that manages the flow of the automated X-ray experiments; sample exchanges, loop-centering and X-ray diffraction data collection. The fully automated data collection function has been available since February 2009. To identify sample cassettes, PAM employs a two-dimensional bar code reader. New beamlines, BL-1A at the Photon Factory and BL32XU at SPring-8, are currently under construction as part of Targeted Proteins Research Program (TPRP) by the Ministry of Education, Culture, Sports, Science and Technology of Japan. However, different robots, PAM and SPACE (SPring-8 Precise Automatic Cryo-sample Exchanger), will be installed at BL-1A and BL32XU, respectively. For the convenience of the users of both facilities, pins and cassettes for PAM and SPACE are developed as part of the TPRP.

  10. Automated Delay Measurement System for an Earth Station for Two-Way Satellite Time and Frequency Transfer

    DTIC Science & Technology

    1994-12-01

    important for improving the TWSTFT capabilities. An automnted system for this purpose has been developed from the initial design at NMi-VSL. It...September 1994 together with a USNO portable station on a calibration trip to European TWSTFT earth staions. 1. Introduction The Two-Way Satellite...Time and Frequency Transfer ( TWSTFT ) method (Fig. I) is used to compare two clocks or time scales which are often located at great distances from each

  11. Determination of nitrite and nitrate in water samples by an automated hydrodynamic sequential injection method.

    PubMed

    Somnam, Sarawut; Jakmunee, Jaroon; Grudpan, Kate; Lenghor, Narong; Motomizu, Shoji

    2008-12-01

    An automated hydrodynamic sequential injection (HSI) system with spectrophotometric detection was developed. Thanks to the hydrodynamic injection principle, simple devices can be used for introducing reproducible microliter volumes of both sample and reagent into the flow channel to form stacked zones in a similar fashion to those in a sequential injection system. The zones were then pushed to the detector and a peak profile was recorded. The determination of nitrite and nitrate in water samples by employing the Griess reaction was chosen as a model. Calibration graphs with linearity in the range of 0.7 - 40 muM were obtained for both nitrite and nitrate. Detection limits were found to be 0.3 muM NO(2)(-) and 0.4 muM NO(3)(-), respectively, with a sample throughput of 20 h(-1) for consecutive determination of both the species. The developed system was successfully applied to the analysis of water samples, employing simple and cost-effective instrumentation and offering higher degrees of automation and low chemical consumption.

  12. A novel flow injection chemiluminescence method for automated and miniaturized determination of phenols in smoked food samples.

    PubMed

    Vakh, Christina; Evdokimova, Ekaterina; Pochivalov, Aleksei; Moskvin, Leonid; Bulatov, Andrey

    2017-12-15

    An easily performed fully automated and miniaturized flow injection chemiluminescence (CL) method for determination of phenols in smoked food samples has been proposed. This method includes the ultrasound assisted solid-liquid extraction coupled with gas-diffusion separation of phenols from smoked food sample and analytes absorption into a NaOH solution in a specially designed gas-diffusion cell. The flow system was designed to focus on automation and miniaturization with minimal sample and reagent consumption by inexpensive instrumentation. The luminol - N-bromosuccinimide system in an alkaline medium was used for the CL determination of phenols. The limit of detection of the proposed procedure was 3·10 -8 ·molL -1 (0.01mgkg -1 ) in terms of phenol. The presented method demonstrated to be a good tool for easy, rapid and cost-effective point-of-need screening phenols in smoked food samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Automated Sensitivity Analysis of Interplanetary Trajectories

    NASA Technical Reports Server (NTRS)

    Knittel, Jeremy; Hughes, Kyle; Englander, Jacob; Sarli, Bruno

    2017-01-01

    This work describes a suite of Python tools known as the Python EMTG Automated Trade Study Application (PEATSA). PEATSA was written to automate the operation of trajectory optimization software, simplify the process of performing sensitivity analysis, and was ultimately found to out-perform a human trajectory designer in unexpected ways. These benefits will be discussed and demonstrated on sample mission designs.

  14. Automated microfluidic platform for studies of carbon dioxide dissolution and solubility in physical solvents.

    PubMed

    Abolhasani, Milad; Singh, Mayank; Kumacheva, Eugenia; Günther, Axel

    2012-05-07

    We present an automated microfluidic (MF) approach for the systematic and rapid investigation of carbon dioxide (CO(2)) mass transfer and solubility in physical solvents. Uniformly sized bubbles of CO(2) with lengths exceeding the width of the microchannel (plugs) were isothermally generated in a co-flowing physical solvent within a gas-impermeable, silicon-based MF platform that is compatible with a wide range of solvents, temperatures and pressures. We dynamically determined the volume reduction of the plugs from images that were accommodated within a single field of view, six different downstream locations of the microchannel at any given flow condition. Evaluating plug sizes in real time allowed our automated strategy to suitably select inlet pressures and solvent flow rates such that otherwise dynamically self-selecting parameters (e.g., the plug size, the solvent segment size, and the plug velocity) could be either kept constant or systematically altered. Specifically, if a constant slug length was imposed, the volumetric dissolution rate of CO(2) could be deduced from the measured rate of plug shrinkage. The solubility of CO(2) in the physical solvent was obtained from a comparison between the terminal and the initial plug sizes. Solubility data were acquired every 5 min and were within 2-5% accuracy as compared to literature data. A parameter space consisting of the plug length, solvent slug length and plug velocity at the microchannel inlet was established for different CO(2)-solvent pairs with high and low gas solubilities. In a case study, we selected the gas-liquid pair CO(2)-dimethyl carbonate (DMC) and volumetric mass transfer coefficients 4-30 s(-1) (translating into mass transfer times between 0.25 s and 0.03 s), and Henry's constants, within the range of 6-12 MPa.

  15. Automation of laboratory testing for infectious diseases using the polymerase chain reaction-- our past, our present, our future.

    PubMed

    Jungkind, D

    2001-01-01

    While it is an extremely powerful and versatile assay method, polymerase chain reaction (PCR) can be a labor-intensive process. Since the advent of commercial test kits from Roche and the semi-automated microwell Amplicor system, PCR has become an increasingly useful and widespread clinical tool. However, more widespread acceptance of molecular testing will depend upon automation that allows molecular assays to enter the routine clinical laboratory. The forces driving the need for automated PCR are the requirements for diagnosis and treatment of chronic viral diseases, economic pressures to develop more automated and less expensive test procedures similar to those in the clinical chemistry laboratories, and a shortage in many areas of qualified laboratory personnel trained in the types of manual procedures used in past decades. The automated Roche COBAS AMPLICOR system has automated the amplification and detection process. Specimen preparation remains the most labor-intensive part of the PCR testing process, accounting for the majority of the hands-on-time in most of the assays. A new automated specimen preparation system, the COBAS AmpliPrep, was evaluated. The system automatically releases the target nucleic acid, captures the target with specific oligonucleotide probes, which become attached to magnetic beads via a biotin-streptavidin binding reaction. Once attached to the beads, the target is purified and concentrated automatically. Results of 298 qualitative and 57 quantitative samples representing a wide range of virus concentrations analyzed after the COBAS AmpliPrep and manual specimen preparation methods, showed that there was no significant difference in qualitative or quantitative hepatitis C virus (HCV) assay performance, respectively. The AmpliPrep instrument decreased the time required to prepare serum or plasma samples for HCV PCR to under 1 min per sample. This was a decrease of 76% compared to the manual specimen preparation method. Systems that can analyze more samples with higher throughput and that can answer more questions about the nature of the microbes that we can presently only detect and quantitate will be needed in the future.

  16. Application of automation and information systems to forensic genetic specimen processing.

    PubMed

    Leclair, Benoît; Scholl, Tom

    2005-03-01

    During the last 10 years, the introduction of PCR-based DNA typing technologies in forensic applications has been highly successful. This technology has become pervasive throughout forensic laboratories and it continues to grow in prevalence. For many criminal cases, it provides the most probative evidence. Criminal genotype data banking and victim identification initiatives that follow mass-fatality incidents have benefited the most from the introduction of automation for sample processing and data analysis. Attributes of offender specimens including large numbers, high quality and identical collection and processing are ideal for the application of laboratory automation. The magnitude of kinship analysis required by mass-fatality incidents necessitates the application of computing solutions to automate the task. More recently, the development activities of many forensic laboratories are focused on leveraging experience from these two applications to casework sample processing. The trend toward increased prevalence of forensic genetic analysis will continue to drive additional innovations in high-throughput laboratory automation and information systems.

  17. Dual-Use Space Technology Transfer Conference and Exhibition. Volume 2

    NASA Technical Reports Server (NTRS)

    Krishen, Kumar (Compiler)

    1994-01-01

    This is the second volume of papers presented at the Dual-Use Space Technology Transfer Conference and Exhibition held at the Johnson Space Center February 1-3, 1994. Possible technology transfers covered during the conference were in the areas of information access; innovative microwave and optical applications; materials and structures; marketing and barriers; intelligent systems; human factors and habitation; communications and data systems; business process and technology transfer; software engineering; biotechnology and advanced bioinstrumentation; communications signal processing and analysis; medical care; applications derived from control center data systems; human performance evaluation; technology transfer methods; mathematics, modeling, and simulation; propulsion; software analysis and decision tools; systems/processes in human support technology; networks, control centers, and distributed systems; power; rapid development; perception and vision technologies; integrated vehicle health management; automation technologies; advanced avionics; and robotics technologies.

  18. Space shuttle main engine anomaly data and inductive knowledge based systems: Automated corporate expertise

    NASA Technical Reports Server (NTRS)

    Modesitt, Kenneth L.

    1987-01-01

    Progress is reported on the development of SCOTTY, an expert knowledge-based system to automate the analysis procedure following test firings of the Space Shuttle Main Engine (SSME). The integration of a large-scale relational data base system, a computer graphics interface for experts and end-user engineers, potential extension of the system to flight engines, application of the system for training of newly-hired engineers, technology transfer to other engines, and the essential qualities of good software engineering practices for building expert knowledge-based systems are among the topics discussed.

  19. Management of information in a research and development agency

    NASA Technical Reports Server (NTRS)

    Keene, Wallace O.

    1990-01-01

    The NASA program for managing scientific and technical information (STI) is examined, noting the technological, managerial, educational, and legal aspects of transferring and disseminating information. A definition of STI is introduced and NASA's STI-related management programs are outlined. Consideration is given to the role of STI management in NASA mission programs, research efforts supporting the management and use of STI, STI program interfaces, and the Automated Information Management Program to eliminate redundant automation efforts in common administrative functions. The infrastructure needed to manage the broad base of NASA information and the interfaces between NASA's STI management and external organizations are described.

  20. Spacecraft Health Automated Reasoning Prototype (SHARP): The fiscal year 1989 SHARP portability evaluations task for NASA Solar System Exploration Division's Voyager project

    NASA Technical Reports Server (NTRS)

    Atkinson, David J.; Doyle, Richard J.; James, Mark L.; Kaufman, Tim; Martin, R. Gaius

    1990-01-01

    A Spacecraft Health Automated Reasoning Prototype (SHARP) portability study is presented. Some specific progress is described on the portability studies, plans for technology transfer, and potential applications of SHARP and related artificial intelligence technology to telescience operations. The application of SHARP to Voyager telecommunications was a proof-of-capability demonstration of artificial intelligence as applied to the problem of real time monitoring functions in planetary mission operations. An overview of the design and functional description of the SHARP system is also presented as it was applied to Voyager.

  1. NIST Automated Manufacturing Research Facility (AMRF): March 1987

    NASA Technical Reports Server (NTRS)

    Herbert, Judith E. (Editor); Kane, Richard (Editor)

    1987-01-01

    The completion and advances to the NIST Automated Manufacturing Research Facility (AMRF) is described in this video. The six work stations: (1) horizontal machining; (2) vertical machining; (3) turning machinery; (4) cleaning and deburring; (5) materials handling; and (6) inspection are shown and uses for each workstation are cited. Visiting researchers and scientists within NIST describe the advantages of each of the workstations, what the facility is used for, future applications for the technological advancements from the AMRF, including examples of how AMRF technology is being transferred to the U.S. Navy industry and discuss future technological goals for the facility.

  2. Quantitative and qualitative measure of intralaboratory two-dimensional protein gel reproducibility and the effects of sample preparation, sample load, and image analysis.

    PubMed

    Choe, Leila H; Lee, Kelvin H

    2003-10-01

    We investigate one approach to assess the quantitative variability in two-dimensional gel electrophoresis (2-DE) separations based on gel-to-gel variability, sample preparation variability, sample load differences, and the effect of automation on image analysis. We observe that 95% of spots present in three out of four replicate gels exhibit less than a 0.52 coefficient of variation (CV) in fluorescent stain intensity (% volume) for a single sample run on multiple gels. When four parallel sample preparations are performed, this value increases to 0.57. We do not observe any significant change in quantitative value for an increase or decrease in sample load of 30% when using appropriate image analysis variables. Increasing use of automation, while necessary in modern 2-DE experiments, does change the observed level of quantitative and qualitative variability among replicate gels. The number of spots that change qualitatively for a single sample run in parallel varies from a CV = 0.03 for fully manual analysis to CV = 0.20 for a fully automated analysis. We present a systematic method by which a single laboratory can measure gel-to-gel variability using only three gel runs.

  3. DDL:Digital systems design language

    NASA Technical Reports Server (NTRS)

    Shival, S. G.

    1980-01-01

    Hardware description languages are valuable tools in such applications as hardware design, system documentation, and logic design training. DDL is convenient medium for inputting design details into hardware-design automation system. It is suitable for describing digital systems at gate, register transfer, and major combinational block level.

  4. Nespoli and Kaleri work in the ATV 2

    NASA Image and Video Library

    2011-02-25

    ISS026-E-029680 (25 Feb. 2011) --- European Space Agency astronaut Paolo Nespoli (top) and Russian cosmonaut Alexander Kaleri, both Expedition 26 flight engineers, work in the newly-attached European Space Agency's "Johannes Kepler" Automated Transfer Vehicle-2 (ATV-2) of the International Space Station.

  5. ATV docking ops

    NASA Image and Video Library

    2014-08-12

    ISS040-E-091634 (12 Aug. 2014) --- In the Zvezda Service Module, European Space Agency astronaut Alexander Gerst (left) and Russian cosmonaut Alexander Skvortsov, both Expedition 40 flight engineers, monitor the approach and docking of ESA's "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5) to the International Space Station.

  6. ATV 2 Approach

    NASA Image and Video Library

    2011-02-24

    ISS026-E-029450 (24 Feb. 2011) --- Backdropped by a blue and white part of Earth, the European Space Agency's "Johannes Kepler" Automated Transfer Vehicle-2 (ATV-2) approaches the International Space Station. Docking of the two spacecraft occurred at 10:59 a.m. (EST) on Feb. 24, 2011.

  7. Nespoli and Kaleri work in the ATV 2

    NASA Image and Video Library

    2011-02-25

    ISS026-E-029677 (25 Feb. 2011) --- European Space Agency astronaut Paolo Nespoli (right) and Russian cosmonaut Alexander Kaleri, both Expedition 26 flight engineers, work in the newly-attached European Space Agency's "Johannes Kepler" Automated Transfer Vehicle-2 (ATV-2) of the International Space Station.

  8. Nespoli and Kaleri in the ATV 2

    NASA Image and Video Library

    2011-02-25

    ISS026-E-029702 (25 Feb. 2011) --- European Space Agency astronaut Paolo Nespoli (top) and Russian cosmonaut Alexander Kaleri, both Expedition 26 flight engineers, work in the newly-attached European Space Agency's "Johannes Kepler" Automated Transfer Vehicle-2 (ATV-2) of the International Space Station.

  9. ATV docking ops

    NASA Image and Video Library

    2014-08-12

    ISS040-E-091638 (12 Aug. 2014) --- In the Zvezda Service Module, European Space Agency astronaut Alexander Gerst (left) and Russian cosmonaut Alexander Skvortsov, both Expedition 40 flight engineers, monitor the approach and docking of ESA's "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5) to the International Space Station.

  10. ATV docking ops

    NASA Image and Video Library

    2014-08-12

    ISS040-E-091635 (12 Aug. 2014) --- In the Zvezda Service Module, European Space Agency astronaut Alexander Gerst (left) and Russian cosmonaut Alexander Skvortsov, both Expedition 40 flight engineers, monitor the approach and docking of ESA's "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5) to the International Space Station.

  11. Nespoli and Kaleri in the ATV 2

    NASA Image and Video Library

    2011-02-25

    ISS026-E-029705 (25 Feb. 2011) --- European Space Agency astronaut Paolo Nespoli (left) and Russian cosmonaut Alexander Kaleri, both Expedition 26 flight engineers, are pictured in the newly-attached European Space Agency's "Johannes Kepler" Automated Transfer Vehicle-2 (ATV-2) of the International Space Station.

  12. Kuipers uses drill in the ATV-3

    NASA Image and Video Library

    2012-03-31

    ISS030-E-178670 (31 March 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, works in the newly attached European Space Agency?s ?Edoardo Amaldi? Automated Transfer Vehicle-3 (ATV-3). The ATV docked with the space station on March 28, 2012.

  13. ATV docking ops

    NASA Image and Video Library

    2014-08-12

    ISS040-E-091655 (12 Aug. 2014) --- In the Zvezda Service Module, European Space Agency astronaut Alexander Gerst (right) and Russian cosmonaut Alexander Skvortsov, both Expedition 40 flight engineers, monitor the approach and docking of ESA's "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5) to the International Space Station.

  14. ATV docking ops

    NASA Image and Video Library

    2014-08-12

    ISS040-E-091688 (12 Aug. 2014) --- In the Zvezda Service Module, European Space Agency astronaut Alexander Gerst (left) and Russian cosmonaut Alexander Skvortsov, both Expedition 40 flight engineers, monitor the approach and docking of ESA?s "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5) to the International Space Station.

  15. Orbital transfer vehicle concept definition and system analysis study. Volume 4, Appendix A: Space station accommodations. Revision 1

    NASA Technical Reports Server (NTRS)

    Randall, Roger M.

    1987-01-01

    Orbit Transfer Vehicle (OTV) processing at the space station is divided into two major categories: OTV processing and assembly operations, and support operations. These categories are further subdivided into major functional areas to allow development of detailed OTV processing procedures and timelines. These procedures and timelines are used to derive the specific space station accommodations necessary to support OTV activities. The overall objective is to limit impact on OTV processing requirements on space station operations, involvement of crew, and associated crew training and skill requirements. The operational concept maximizes use of automated and robotic systems to perform all required OTV servicing and maintenance tasks. Only potentially critical activities would require direct crew involvement or supervision. EVA operations are considered to be strictly contingency back-up to failure of the automated and robotic systems, with the exception of the initial assembly of Space-Based OTV accommodations at the space station, which will require manned involvement.

  16. Automated Classification and Analysis of Non-metallic Inclusion Data Sets

    NASA Astrophysics Data System (ADS)

    Abdulsalam, Mohammad; Zhang, Tongsheng; Tan, Jia; Webler, Bryan A.

    2018-05-01

    The aim of this study is to utilize principal component analysis (PCA), clustering methods, and correlation analysis to condense and examine large, multivariate data sets produced from automated analysis of non-metallic inclusions. Non-metallic inclusions play a major role in defining the properties of steel and their examination has been greatly aided by automated analysis in scanning electron microscopes equipped with energy dispersive X-ray spectroscopy. The methods were applied to analyze inclusions on two sets of samples: two laboratory-scale samples and four industrial samples from a near-finished 4140 alloy steel components with varying machinability. The laboratory samples had well-defined inclusions chemistries, composed of MgO-Al2O3-CaO, spinel (MgO-Al2O3), and calcium aluminate inclusions. The industrial samples contained MnS inclusions as well as (Ca,Mn)S + calcium aluminate oxide inclusions. PCA could be used to reduce inclusion chemistry variables to a 2D plot, which revealed inclusion chemistry groupings in the samples. Clustering methods were used to automatically classify inclusion chemistry measurements into groups, i.e., no user-defined rules were required.

  17. Mission operations technology

    NASA Astrophysics Data System (ADS)

    Varsi, Giulio

    In the last decade, the operation of a spacecraft after launch has emerged as a major component of the total cost of the mission. This trend is sustained by the increasing complexity, flexibility, and data gathering capability of the space assets and by their greater reliability and consequent longevity. The trend can, however, be moderated by the progressive transfer of selected functions from the ground to the spacecraft and by application, on the ground, of new technology. Advances in ground operations derive from the introduction in the mission operations environment of advanced microprocessor-based workstations in the class of a few million instructions per second and from the selective application of artificial intelligence technology. In the last few years a number of these applications have been developed, tested in operational settings and successfully demonstrated to users. Some are now being integrated in mission operations facilities. An analysis of mission operations indicates that the key areas are: concurrent control of multiple missions; automated/interactive production of command sequences of high integrity at low cost; automated monitoring of spacecraft health and automated aides for fault diagnosis; automated allocation of resources; automated processing of science data; and high-fidelity, high-speed spacecraft simulation. Examples of major advances in selected areas are described.

  18. Automated extraction of DNA from blood and PCR setup using a Tecan Freedom EVO liquid handler for forensic genetic STR typing of reference samples.

    PubMed

    Stangegaard, Michael; Frøslev, Tobias G; Frank-Hansen, Rune; Hansen, Anders J; Morling, Niels

    2011-04-01

    We have implemented and validated automated protocols for DNA extraction and PCR setup using a Tecan Freedom EVO liquid handler mounted with the Te-MagS magnetic separation device (Tecan, Männedorf, Switzerland). The protocols were validated for accredited forensic genetic work according to ISO 17025 using the Qiagen MagAttract DNA Mini M48 kit (Qiagen GmbH, Hilden, Germany) from fresh whole blood and blood from deceased individuals. The workflow was simplified by returning the DNA extracts to the original tubes minimizing the risk of misplacing samples. The tubes that originally contained the samples were washed with MilliQ water before the return of the DNA extracts. The PCR was setup in 96-well microtiter plates. The methods were validated for the kits: AmpFℓSTR Identifiler, SGM Plus and Yfiler (Applied Biosystems, Foster City, CA), GenePrint FFFL and PowerPlex Y (Promega, Madison, WI). The automated protocols allowed for extraction and addition of PCR master mix of 96 samples within 3.5h. In conclusion, we demonstrated that (1) DNA extraction with magnetic beads and (2) PCR setup for accredited, forensic genetic short tandem repeat typing can be implemented on a simple automated liquid handler leading to the reduction of manual work, and increased quality and throughput. Copyright © 2011 Society for Laboratory Automation and Screening. Published by Elsevier Inc. All rights reserved.

  19. [DNA extraction from bones and teeth using AutoMate Express forensic DNA extraction system].

    PubMed

    Gao, Lin-Lin; Xu, Nian-Lai; Xie, Wei; Ding, Shao-Cheng; Wang, Dong-Jing; Ma, Li-Qin; Li, You-Ying

    2013-04-01

    To explore a new method in order to extract DNA from bones and teeth automatically. Samples of 33 bones and 15 teeth were acquired by freeze-mill method and manual method, respectively. DNA materials were extracted and quantified from the triturated samples by AutoMate Express forensic DNA extraction system. DNA extraction from bones and teeth were completed in 3 hours using the AutoMate Express forensic DNA extraction system. There was no statistical difference between the two methods in the DNA concentration of bones. Both bones and teeth got the good STR typing by freeze-mill method, and the DNA concentration of teeth was higher than those by manual method. AutoMate Express forensic DNA extraction system is a new method to extract DNA from bones and teeth, which can be applied in forensic practice.

  20. Cost assessment of the automated VERSANT 440 Molecular System versus the semi-automated System 340 bDNA Analyzer platforms.

    PubMed

    Elbeik, Tarek; Loftus, Richard A; Beringer, Scott

    2007-11-01

    Labor, supply and waste were evaluated for HIV-1 and HCV bDNA on the semi-automated System 340 bDNA Analyzer and the automated VERSANT 440 Molecular System (V440). HIV-1 sample processing was evaluated using a 24- and 48-position centrifuge rotor. Vigilance time (hands-on manipulations plus incubation time except initial target hybridization) and disposables were approximately 37 and 12% lower for HIV-1, and 64 and 31% lower for HCV bDNA, respectively, with V440. Biohazardous solid waste was approximately twofold lower for both assays and other waste types were the same for either assay on both platforms. HIV-1 sample processing vigilance time for the 48-position rotor was reduced by 2 h. V440 provides cost savings and improved workflow.

  1. FLIM FRET Technology for Drug Discovery: Automated Multiwell-Plate High-Content Analysis, Multiplexed Readouts and Application in Situ**

    PubMed Central

    Kumar, Sunil; Alibhai, Dominic; Margineanu, Anca; Laine, Romain; Kennedy, Gordon; McGinty, James; Warren, Sean; Kelly, Douglas; Alexandrov, Yuriy; Munro, Ian; Talbot, Clifford; Stuckey, Daniel W; Kimberly, Christopher; Viellerobe, Bertrand; Lacombe, Francois; Lam, Eric W-F; Taylor, Harriet; Dallman, Margaret J; Stamp, Gordon; Murray, Edward J; Stuhmeier, Frank; Sardini, Alessandro; Katan, Matilda; Elson, Daniel S; Neil, Mark A A; Dunsby, Chris; French, Paul M W

    2011-01-01

    A fluorescence lifetime imaging (FLIM) technology platform intended to read out changes in Förster resonance energy transfer (FRET) efficiency is presented for the study of protein interactions across the drug-discovery pipeline. FLIM provides a robust, inherently ratiometric imaging modality for drug discovery that could allow the same sensor constructs to be translated from automated cell-based assays through small transparent organisms such as zebrafish to mammals. To this end, an automated FLIM multiwell-plate reader is described for high content analysis of fixed and live cells, tomographic FLIM in zebrafish and FLIM FRET of live cells via confocal endomicroscopy. For cell-based assays, an exemplar application reading out protein aggregation using FLIM FRET is presented, and the potential for multiple simultaneous FLIM (FRET) readouts in microscopy is illustrated. PMID:21337485

  2. Towards Automated Nanomanipulation under Scanning Electron Microscopy

    NASA Astrophysics Data System (ADS)

    Ye, Xutao

    Robotic Nanomaterial Manipulation inside scanning electron microscopes (SEM) is useful for prototyping functional devices and characterizing one-dimensional nanomaterial's properties. Conventionally, manipulation of nanowires has been performed via teleoperation, which is time-consuming and highly skill-dependent. Manual manipulation also has the limitation of low success rates and poor reproducibility. This research focuses on a robotic system capable of automated pick-place of single nanowires. Through SEM visual detection and vision-based motion control, the system transferred individual silicon nanowires from their growth substrate to a microelectromechanical systems (MEMS) device that characterized the nanowires' electromechanical properties. The performances of the nanorobotic pick-up and placement procedures were quantified by experiments. The system demonstrated automated nanowire pick-up and placement with high reliability. A software system for a load-lock-compatible nanomanipulation system is also designed and developed in this research.

  3. Automated microfluidic platform for systematic studies of colloidal perovskite nanocrystals: towards continuous nano-manufacturing.

    PubMed

    Epps, Robert W; Felton, Kobi C; Coley, Connor W; Abolhasani, Milad

    2017-11-21

    Colloidal organic/inorganic metal-halide perovskite nanocrystals have recently emerged as a potential low-cost replacement for the semiconductor materials in commercial photovoltaics and light emitting diodes. However, unlike III-V and IV-VI semiconductor nanocrystals, studies of colloidal perovskite nanocrystals have yet to develop a fundamental and comprehensive understanding of nucleation and growth kinetics. Here, we introduce a modular and automated microfluidic platform for the systematic studies of room-temperature synthesized cesium-lead halide perovskite nanocrystals. With abundant data collection across the entirety of four orders of magnitude reaction time span, we comprehensively characterize nanocrystal growth within a modular microfluidic reactor. The developed high-throughput screening platform features a custom-designed three-port flow cell with translational capability for in situ spectral characterization of the in-flow synthesized perovskite nanocrystals along a tubular microreactor with an adjustable length, ranging from 3 cm to 196 cm. The translational flow cell allows for sampling of twenty unique residence times at a single equilibrated flow rate. The developed technique requires an average total liquid consumption of 20 μL per spectra and as little as 2 μL at the time of sampling. It may continuously sample up to 30 000 unique spectra per day in both single and multi-phase flow formats. Using the developed plug-and-play microfluidic platform, we study the growth of cesium lead trihalide perovskite nanocrystals through in situ monitoring of their absorption and emission band-gaps at residence times ranging from 100 ms to 17 min. The automated microfluidic platform enables a systematic study of the effect of mixing enhancement on the quality of the synthesized nanocrystals through a direct comparison between single- and multi-phase flow systems at similar reaction time scales. The improved mixing characteristics of the multi-phase flow format results in high-quality perovskite nanocrystals with kinetically tunable emission wavelength, ranging as much as 25 nm at equivalent residence times. Further application of this unique platform would allow rapid parameter optimization in the colloidal synthesis of a wide range of nanomaterials (e.g., metal or semiconductor), that is directly transferable to continuous manufacturing in a numbered-up platform with a similar characteristic length scale.

  4. Portable Automation of Static Chamber Sample Collection for Quantifying Soil Gas Flux

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Morgan P.; Groh, Tyler A.; Parkin, Timothy B.

    Quantification of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled is limited by the spacing between chambers and the availability of trained research technicians. An automated system for collecting gas samples from chambers in the field would eliminate the need for personnel to return to the chamber during a flux measurement period and would allow a single technician to sample multiple chambers simultaneously. This study describes Chamber Automated Sampling Equipment (FluxCASE) to collect and store chamber headspace gas samples at assigned time points for the measurement of soil gasmore » flux. The FluxCASE design and operation is described, and the accuracy and precision of the FluxCASE system is evaluated. In laboratory measurements of nitrous oxide (N2O), carbon dioxide (CO2), and methane (CH4) concentrations of a standardized gas mixture, coefficients of variation associated with automated and manual sample collection were comparable, indicating no loss of precision. In the field, soil gas fluxes measured from FluxCASEs were in agreement with manual sampling for both N2O and CO2. Slopes of regression equations were 1.01 for CO2 and 0.97 for N2O. The 95% confidence limits of the slopes of the regression lines included the value of one, indicating no bias. Additionally, an expense analysis found a cost recovery ranging from 0.6 to 2.2 yr. Implementing the FluxCASE system is an alternative to improve the efficiency of the static chamber method for measuring soil gas flux while maintaining the accuracy and precision of manual sampling.« less

  5. Automated image analysis for quantitative fluorescence in situ hybridization with environmental samples.

    PubMed

    Zhou, Zhi; Pons, Marie Noëlle; Raskin, Lutgarde; Zilles, Julie L

    2007-05-01

    When fluorescence in situ hybridization (FISH) analyses are performed with complex environmental samples, difficulties related to the presence of microbial cell aggregates and nonuniform background fluorescence are often encountered. The objective of this study was to develop a robust and automated quantitative FISH method for complex environmental samples, such as manure and soil. The method and duration of sample dispersion were optimized to reduce the interference of cell aggregates. An automated image analysis program that detects cells from 4',6'-diamidino-2-phenylindole (DAPI) micrographs and extracts the maximum and mean fluorescence intensities for each cell from corresponding FISH images was developed with the software Visilog. Intensity thresholds were not consistent even for duplicate analyses, so alternative ways of classifying signals were investigated. In the resulting method, the intensity data were divided into clusters using fuzzy c-means clustering, and the resulting clusters were classified as target (positive) or nontarget (negative). A manual quality control confirmed this classification. With this method, 50.4, 72.1, and 64.9% of the cells in two swine manure samples and one soil sample, respectively, were positive as determined with a 16S rRNA-targeted bacterial probe (S-D-Bact-0338-a-A-18). Manual counting resulted in corresponding values of 52.3, 70.6, and 61.5%, respectively. In two swine manure samples and one soil sample 21.6, 12.3, and 2.5% of the cells were positive with an archaeal probe (S-D-Arch-0915-a-A-20), respectively. Manual counting resulted in corresponding values of 22.4, 14.0, and 2.9%, respectively. This automated method should facilitate quantitative analysis of FISH images for a variety of complex environmental samples.

  6. The feasibility of automated online flow cytometry for in-situ monitoring of microbial dynamics in aquatic ecosystems

    PubMed Central

    Besmer, Michael D.; Weissbrodt, David G.; Kratochvil, Bradley E.; Sigrist, Jürg A.; Weyland, Mathias S.; Hammes, Frederik

    2014-01-01

    Fluorescent staining coupled with flow cytometry (FCM) is often used for the monitoring, quantification and characterization of bacteria in engineered and environmental aquatic ecosystems including seawater, freshwater, drinking water, wastewater, and industrial bioreactors. However, infrequent grab sampling hampers accurate characterization and subsequent understanding of microbial dynamics in all of these ecosystems. A logic technological progression is high throughput and full automation of the sampling, staining, measurement, and data analysis steps. Here we assess the feasibility and applicability of automated FCM by means of actual data sets produced with prototype instrumentation. As proof-of-concept we demonstrate examples of microbial dynamics in (i) flowing tap water from a municipal drinking water supply network and (ii) river water from a small creek subject to two rainfall events. In both cases, automated measurements were done at 15-min intervals during 12–14 consecutive days, yielding more than 1000 individual data points for each ecosystem. The extensive data sets derived from the automated measurements allowed for the establishment of baseline data for each ecosystem, as well as for the recognition of daily variations and specific events that would most likely be missed (or miss-characterized) by infrequent sampling. In addition, the online FCM data from the river water was combined and correlated with online measurements of abiotic parameters, showing considerable potential for a better understanding of cause-and-effect relationships in aquatic ecosystems. Although several challenges remain, the successful operation of an automated online FCM system and the basic interpretation of the resulting data sets represent a breakthrough toward the eventual establishment of fully automated online microbiological monitoring technologies. PMID:24917858

  7. Technical notes: A detailed study for the provision of measurement uncertainty and traceability for goniospectrometers

    NASA Astrophysics Data System (ADS)

    Peltoniemi, Jouni I.; Hakala, Teemu; Suomalainen, Juha; Honkavaara, Eija; Markelin, Lauri; Gritsevich, Maria; Eskelinen, Juho; Jaanson, Priit; Ikonen, Erkki

    2014-10-01

    The measurement uncertainty and traceability of the Finnish Geodetic Institutess field gonio-spectro-polarimeter FIGIFIGO have been assessed. First, the reference standard (Spectralon sample) was measured at the National Standard Laboratory of MIKES-Aalto. This standard was transferred to FGIs field reference standard (larger Spectralon sample), and from that to the unmanned aerial vehicle (UAV), reference standards (1 m2 plates). The reflectance measurement uncertainty of FIGIFIGO has been estimated to be 0.01 in ideal laboratory conditions, but about 0.02-0.05 in typical field conditions, larger at larger solar or observation zenith angles. Target specific uncertainties can increase total uncertainty even to 0.1-0.2. The angular reading uncertainty is between 1° and 3°, depending on user selection, and the polarisation uncertainty is around 0.01. For UAV, the transferred reflectance uncertainty is about 0.05-0.1, depending on, how ideal the measurement conditions are. The design concept of FIGIFIGO has been proved to have a number of advantages, such as a well-adopted user-friendly interface, a high level of automation and excellent suitability for the field measurements. It is a perfect instrument for collection of reference data on a given target in natural (and well-recorded) conditions. In addition to the strong points of FIGIFIGO, the current study reveals several issues that need further attention, such as the field of view, illumination quality, polarisation calibration, Spectralon reflectance and polarisation properties in the 1000-2400 nm range.

  8. Automated Sensitivity Analysis of Interplanetary Trajectories for Optimal Mission Design

    NASA Technical Reports Server (NTRS)

    Knittel, Jeremy; Hughes, Kyle; Englander, Jacob; Sarli, Bruno

    2017-01-01

    This work describes a suite of Python tools known as the Python EMTG Automated Trade Study Application (PEATSA). PEATSA was written to automate the operation of trajectory optimization software, simplify the process of performing sensitivity analysis, and was ultimately found to out-perform a human trajectory designer in unexpected ways. These benefits will be discussed and demonstrated on sample mission designs.

  9. Practical interpretation of CYP2D6 haplotypes: Comparison and integration of automated and expert calling.

    PubMed

    Ruaño, Gualberto; Kocherla, Mohan; Graydon, James S; Holford, Theodore R; Makowski, Gregory S; Goethe, John W

    2016-05-01

    We describe a population genetic approach to compare samples interpreted with expert calling (EC) versus automated calling (AC) for CYP2D6 haplotyping. The analysis represents 4812 haplotype calls based on signal data generated by the Luminex xMap analyzers from 2406 patients referred to a high-complexity molecular diagnostics laboratory for CYP450 testing. DNA was extracted from buccal swabs. We compared the results of expert calls (EC) and automated calls (AC) with regard to haplotype number and frequency. The ratio of EC to AC was 1:3. Haplotype frequencies from EC and AC samples were convergent across haplotypes, and their distribution was not statistically different between the groups. Most duplications required EC, as only expansions with homozygous or hemizygous haplotypes could be automatedly called. High-complexity laboratories can offer equivalent interpretation to automated calling for non-expanded CYP2D6 loci, and superior interpretation for duplications. We have validated scientific expert calling specified by scoring rules as standard operating procedure integrated with an automated calling algorithm. The integration of EC with AC is a practical strategy for CYP2D6 clinical haplotyping. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Evaluation of automated sample preparation, retention time locked gas chromatography-mass spectrometry and data analysis methods for the metabolomic study of Arabidopsis species.

    PubMed

    Gu, Qun; David, Frank; Lynen, Frédéric; Rumpel, Klaus; Dugardeyn, Jasper; Van Der Straeten, Dominique; Xu, Guowang; Sandra, Pat

    2011-05-27

    In this paper, automated sample preparation, retention time locked gas chromatography-mass spectrometry (GC-MS) and data analysis methods for the metabolomics study were evaluated. A miniaturized and automated derivatisation method using sequential oximation and silylation was applied to a polar extract of 4 types (2 types×2 ages) of Arabidopsis thaliana, a popular model organism often used in plant sciences and genetics. Automation of the derivatisation process offers excellent repeatability, and the time between sample preparation and analysis was short and constant, reducing artifact formation. Retention time locked (RTL) gas chromatography-mass spectrometry was used, resulting in reproducible retention times and GC-MS profiles. Two approaches were used for data analysis. XCMS followed by principal component analysis (approach 1) and AMDIS deconvolution combined with a commercially available program (Mass Profiler Professional) followed by principal component analysis (approach 2) were compared. Several features that were up- or down-regulated in the different types were detected. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. FlexED8: the first member of a fast and flexible sample-changer family for macromolecular crystallography.

    PubMed

    Papp, Gergely; Felisaz, Franck; Sorez, Clement; Lopez-Marrero, Marcos; Janocha, Robert; Manjasetty, Babu; Gobbo, Alexandre; Belrhali, Hassan; Bowler, Matthew W; Cipriani, Florent

    2017-10-01

    Automated sample changers are now standard equipment for modern macromolecular crystallography synchrotron beamlines. Nevertheless, most are only compatible with a single type of sample holder and puck. Recent work aimed at reducing sample-handling efforts and crystal-alignment times at beamlines has resulted in a new generation of compact and precise sample holders for cryocrystallography: miniSPINE and NewPin [see the companion paper by Papp et al. (2017, Acta Cryst., D73, 829-840)]. With full data collection now possible within seconds at most advanced beamlines, and future fourth-generation synchrotron sources promising to extract data in a few tens of milliseconds, the time taken to mount and centre a sample is rate-limiting. In this context, a versatile and fast sample changer, FlexED8, has been developed that is compatible with the highly successful SPINE sample holder and with the miniSPINE and NewPin sample holders. Based on a six-axis industrial robot, FlexED8 is equipped with a tool changer and includes a novel open sample-storage dewar with a built-in ice-filtering system. With seven versatile puck slots, it can hold up to 112 SPINE sample holders in uni-pucks, or 252 miniSPINE or NewPin sample holders, with 36 samples per puck. Additionally, a double gripper, compatible with the SPINE sample holders and uni-pucks, allows a reduction in the sample-exchange time from 40 s, the typical time with a standard single gripper, to less than 5 s. Computer vision-based sample-transfer monitoring, sophisticated error handling and automatic error-recovery procedures ensure high reliability. The FlexED8 sample changer has been successfully tested under real conditions on a beamline.

  12. Automated CD-SEM recipe creation technology for mass production using CAD data

    NASA Astrophysics Data System (ADS)

    Kawahara, Toshikazu; Yoshida, Masamichi; Tanaka, Masashi; Ido, Sanyu; Nakano, Hiroyuki; Adachi, Naokaka; Abe, Yuichi; Nagatomo, Wataru

    2011-03-01

    Critical Dimension Scanning Electron Microscope (CD-SEM) recipe creation needs sample preparation necessary for matching pattern registration, and recipe creation on CD-SEM using the sample, which hinders the reduction in test production cost and time in semiconductor manufacturing factories. From the perspective of cost reduction and improvement of the test production efficiency, automated CD-SEM recipe creation without the sample preparation and the manual operation has been important in the production lines. For the automated CD-SEM recipe creation, we have introduced RecipeDirector (RD) that enables the recipe creation by using Computer-Aided Design (CAD) data and text data that includes measurement information. We have developed a system that automatically creates the CAD data and the text data necessary for the recipe creation on RD; and, for the elimination of the manual operation, we have enhanced RD so that all measurement information can be specified in the text data. As a result, we have established an automated CD-SEM recipe creation system without the sample preparation and the manual operation. For the introduction of the CD-SEM recipe creation system using RD to the production lines, the accuracy of the pattern matching was an issue. The shape of design templates for the matching created from the CAD data was different from that of SEM images in vision. Thus, a development of robust pattern matching algorithm that considers the shape difference was needed. The addition of image processing of the templates for the matching and shape processing of the CAD patterns in the lower layer has enabled the robust pattern matching. This paper describes the automated CD-SEM recipe creation technology for the production lines without the sample preparation and the manual operation using RD applied in Sony Semiconductor Kyusyu Corporation Kumamoto Technology Center (SCK Corporation Kumamoto TEC).

  13. Driving Performance After Self-Regulated Control Transitions in Highly Automated Vehicles.

    PubMed

    Eriksson, Alexander; Stanton, Neville A

    2017-12-01

    This study aims to explore whether driver-paced, noncritical transitions of control may counteract some of the aftereffects observed in the contemporary literature, resulting in higher levels of vehicle control. Research into control transitions in highly automated driving has focused on urgent scenarios where drivers are given a relatively short time span to respond to a request to resume manual control, resulting in seemingly scrambled control when manual control is resumed. Twenty-six drivers drove two scenarios with an automated driving feature activated. Drivers were asked to read a newspaper or monitor the system and relinquish or resume control from the automation when prompted by vehicle systems. Driving performance in terms of lane positioning and steering behavior was assessed for 20 seconds post resuming control to capture the resulting level of control. It was found that lane positioning was virtually unaffected for the duration of the 20-second time span in both automated conditions compared to the manual baseline when drivers resumed manual control; however, significant increases in the standard deviation of steering input were found for both automated conditions compared to baseline. No significant differences were found between the two automated conditions. The results indicate that when drivers self-paced the transfer back to manual control they exhibit less of the detrimental effects observed in system-paced conditions. It was shown that self-paced transitions could reduce the risk of accidents near the edge of the operational design domain. Vehicle manufacturers must consider these benefits when designing contemporary systems.

  14. An Automated Slide Classification System at Georgia Tech

    ERIC Educational Resources Information Center

    LoPresti, Maryellen

    1973-01-01

    The Georgia Tech Architecture Library slide collection is being revolutionized by adapting the Santa Cruz Slide Classification System. The slide catalog record is being transferred inexpensively to tapes and updated by the computer. Computer programs print out indexes in any of fifteen different sort fields. (Author)

  15. Volkov and Kononenko in the ATV during Expedition 17

    NASA Image and Video Library

    2008-05-12

    ISS017-E-006544 (12 May 2008) --- Russian Federal Space Agency cosmonauts Sergei Volkov (left), Expedition 17 commander, and Oleg Kononenko, flight engineer, take a moment for a photo in the Jules Verne Automated Transfer Vehicle (ATV) while it remains docked with the International Space Station.

  16. Volkov and Kononenko in the ATV during Expedition 17

    NASA Image and Video Library

    2008-05-12

    ISS017-E-006543 (12 May 2008) --- Russian Federal Space Agency cosmonauts Sergei Volkov (bottom), Expedition 17 commander, and Oleg Kononenko, flight engineer, take a moment for a photo in the Jules Verne Automated Transfer Vehicle (ATV) while it remains docked with the International Space Station.

  17. Kuipers unpacks CTBs in the ATV-3

    NASA Image and Video Library

    2012-03-31

    ISS030-E-178659 (31 March 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, unpacks stowage containers in the newly attached European Space Agency?s ?Edoardo Amaldi? Automated Transfer Vehicle-3 (ATV-3). The ATV docked with the space station on March 28, 2012.

  18. Design of personal rapid transit networks for transit-oriented development cities.

    DOT National Transportation Integrated Search

    2014-04-01

    Personal rapid transit (PRT) is an automated transit system in which vehicles are sized to transport a batch of passengers on demand to their destinations, by means of nonstop and non-transfer on its own right-of-way. PRT vehicles run exclusively on ...

  19. Heterogeneous Wireless Networks for Smart Grid Distribution Systems: Advantages and Limitations.

    PubMed

    Khalifa, Tarek; Abdrabou, Atef; Shaban, Khaled; Gaouda, A M

    2018-05-11

    Supporting a conventional power grid with advanced communication capabilities is a cornerstone to transferring it to a smart grid. A reliable communication infrastructure with a high throughput can lay the foundation towards the ultimate objective of a fully automated power grid with self-healing capabilities. In order to realize this objective, the communication infrastructure of a power distribution network needs to be extended to cover all substations including medium/low voltage ones. This shall enable information exchange among substations for a variety of system automation purposes with a low latency that suits time critical applications. This paper proposes the integration of two heterogeneous wireless technologies (such as WiFi and cellular 3G/4G) to provide reliable and fast communication among primary and secondary distribution substations. This integration allows the transmission of different data packets (not packet replicas) over two radio interfaces, making these interfaces act like a one data pipe. Thus, the paper investigates the applicability and effectiveness of employing heterogeneous wireless networks (HWNs) in achieving the desired reliability and timeliness requirements of future smart grids. We study the performance of HWNs in a realistic scenario under different data transfer loads and packet loss ratios. Our findings reveal that HWNs can be a viable data transfer option for smart grids.

  20. Heterogeneous Wireless Networks for Smart Grid Distribution Systems: Advantages and Limitations

    PubMed Central

    Khalifa, Tarek; Abdrabou, Atef; Gaouda, A. M.

    2018-01-01

    Supporting a conventional power grid with advanced communication capabilities is a cornerstone to transferring it to a smart grid. A reliable communication infrastructure with a high throughput can lay the foundation towards the ultimate objective of a fully automated power grid with self-healing capabilities. In order to realize this objective, the communication infrastructure of a power distribution network needs to be extended to cover all substations including medium/low voltage ones. This shall enable information exchange among substations for a variety of system automation purposes with a low latency that suits time critical applications. This paper proposes the integration of two heterogeneous wireless technologies (such as WiFi and cellular 3G/4G) to provide reliable and fast communication among primary and secondary distribution substations. This integration allows the transmission of different data packets (not packet replicas) over two radio interfaces, making these interfaces act like a one data pipe. Thus, the paper investigates the applicability and effectiveness of employing heterogeneous wireless networks (HWNs) in achieving the desired reliability and timeliness requirements of future smart grids. We study the performance of HWNs in a realistic scenario under different data transfer loads and packet loss ratios. Our findings reveal that HWNs can be a viable data transfer option for smart grids. PMID:29751633

  1. Simple determination of fluoride in biological samples by headspace solid-phase microextraction and gas chromatography-tandem mass spectrometry.

    PubMed

    Kwon, Sun-Myung; Shin, Ho-Sang

    2015-08-14

    A simple and convenient method to detect fluoride in biological samples was developed. This method was based on derivatization with 2-(bromomethyl)naphthalene, headspace solid phase microextraction (HS-SPME) in a vial, and gas chromatography-tandem mass spectrometric detection. The HS-SPME parameters were optimized as follows: selection of CAR/PDMS fiber, 0.5% 2-(bromomethyl)naphthalene, 250 mg/L 15-crown-5-ether as a phase transfer catalyst, extraction and derivatization temperature of 95 °C, heating time of 20 min and pH of 7.0. Under the established conditions, the lowest limits of detection were 9 and 11 μg/L in 1.0 ml of plasma and urine, respectively, and the intra- and inter-day relative standard deviation was less than 7.7% at concentrations of 0.1 and 1.0 mg/L. The calibration curve showed good linearity of plasma and urine with r=0.9990 and r=0.9992, respectively. This method is simple, amenable to automation and environmentally friendly. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Mobile phone based SCADA for industrial automation.

    PubMed

    Ozdemir, Engin; Karacor, Mevlut

    2006-01-01

    SCADA is the acronym for "Supervisory Control And Data Acquisition." SCADA systems are widely used in industry for supervisory control and data acquisition of industrial processes. Conventional SCADA systems use PC, notebook, thin client, and PDA as a client. In this paper, a Java-enabled mobile phone has been used as a client in a sample SCADA application in order to display and supervise the position of a sample prototype crane. The paper presents an actual implementation of the on-line controlling of the prototype crane via mobile phone. The wireless communication between the mobile phone and the SCADA server is performed by means of a base station via general packet radio service (GPRS) and wireless application protocol (WAP). Test results have indicated that the mobile phone based SCADA integration using the GPRS or WAP transfer scheme could enhance the performance of the crane in a day without causing an increase in the response times of SCADA functions. The operator can visualize and modify the plant parameters using his mobile phone, without reaching the site. In this way maintenance costs are reduced and productivity is increased.

  3. Automated segmentation of thyroid gland on CT images with multi-atlas label fusion and random classification forest

    NASA Astrophysics Data System (ADS)

    Liu, Jiamin; Chang, Kevin; Kim, Lauren; Turkbey, Evrim; Lu, Le; Yao, Jianhua; Summers, Ronald

    2015-03-01

    The thyroid gland plays an important role in clinical practice, especially for radiation therapy treatment planning. For patients with head and neck cancer, radiation therapy requires a precise delineation of the thyroid gland to be spared on the pre-treatment planning CT images to avoid thyroid dysfunction. In the current clinical workflow, the thyroid gland is normally manually delineated by radiologists or radiation oncologists, which is time consuming and error prone. Therefore, a system for automated segmentation of the thyroid is desirable. However, automated segmentation of the thyroid is challenging because the thyroid is inhomogeneous and surrounded by structures that have similar intensities. In this work, the thyroid gland segmentation is initially estimated by multi-atlas label fusion algorithm. The segmentation is refined by supervised statistical learning based voxel labeling with a random forest algorithm. Multiatlas label fusion (MALF) transfers expert-labeled thyroids from atlases to a target image using deformable registration. Errors produced by label transfer are reduced by label fusion that combines the results produced by all atlases into a consensus solution. Then, random forest (RF) employs an ensemble of decision trees that are trained on labeled thyroids to recognize features. The trained forest classifier is then applied to the thyroid estimated from the MALF by voxel scanning to assign the class-conditional probability. Voxels from the expert-labeled thyroids in CT volumes are treated as positive classes; background non-thyroid voxels as negatives. We applied this automated thyroid segmentation system to CT scans of 20 patients. The results showed that the MALF achieved an overall 0.75 Dice Similarity Coefficient (DSC) and the RF classification further improved the DSC to 0.81.

  4. Homology and phylogeny and their automated inference

    NASA Astrophysics Data System (ADS)

    Fuellen, Georg

    2008-06-01

    The analysis of the ever-increasing amount of biological and biomedical data can be pushed forward by comparing the data within and among species. For example, an integrative analysis of data from the genome sequencing projects for various species traces the evolution of the genomes and identifies conserved and innovative parts. Here, I review the foundations and advantages of this “historical” approach and evaluate recent attempts at automating such analyses. Biological data is comparable if a common origin exists (homology), as is the case for members of a gene family originating via duplication of an ancestral gene. If the family has relatives in other species, we can assume that the ancestral gene was present in the ancestral species from which all the other species evolved. In particular, describing the relationships among the duplicated biological sequences found in the various species is often possible by a phylogeny, which is more informative than homology statements. Detecting and elaborating on common origins may answer how certain biological sequences developed, and predict what sequences are in a particular species and what their function is. Such knowledge transfer from sequences in one species to the homologous sequences of the other is based on the principle of ‘my closest relative looks and behaves like I do’, often referred to as ‘guilt by association’. To enable knowledge transfer on a large scale, several automated ‘phylogenomics pipelines’ have been developed in recent years, and seven of these will be described and compared. Overall, the examples in this review demonstrate that homology and phylogeny analyses, done on a large (and automated) scale, can give insights into function in biology and biomedicine.

  5. Autopilot for frequency-modulation atomic force microscopy.

    PubMed

    Kuchuk, Kfir; Schlesinger, Itai; Sivan, Uri

    2015-10-01

    One of the most challenging aspects of operating an atomic force microscope (AFM) is finding optimal feedback parameters. This statement applies particularly to frequency-modulation AFM (FM-AFM), which utilizes three feedback loops to control the cantilever excitation amplitude, cantilever excitation frequency, and z-piezo extension. These loops are regulated by a set of feedback parameters, tuned by the user to optimize stability, sensitivity, and noise in the imaging process. Optimization of these parameters is difficult due to the coupling between the frequency and z-piezo feedback loops by the non-linear tip-sample interaction. Four proportional-integral (PI) parameters and two lock-in parameters regulating these loops require simultaneous optimization in the presence of a varying unknown tip-sample coupling. Presently, this optimization is done manually in a tedious process of trial and error. Here, we report on the development and implementation of an algorithm that computes the control parameters automatically. The algorithm reads the unperturbed cantilever resonance frequency, its quality factor, and the z-piezo driving signal power spectral density. It analyzes the poles and zeros of the total closed loop transfer function, extracts the unknown tip-sample transfer function, and finds four PI parameters and two lock-in parameters for the frequency and z-piezo control loops that optimize the bandwidth and step response of the total system. Implementation of the algorithm in a home-built AFM shows that the calculated parameters are consistently excellent and rarely require further tweaking by the user. The new algorithm saves the precious time of experienced users, facilitates utilization of FM-AFM by casual users, and removes the main hurdle on the way to fully automated FM-AFM.

  6. Autopilot for frequency-modulation atomic force microscopy

    NASA Astrophysics Data System (ADS)

    Kuchuk, Kfir; Schlesinger, Itai; Sivan, Uri

    2015-10-01

    One of the most challenging aspects of operating an atomic force microscope (AFM) is finding optimal feedback parameters. This statement applies particularly to frequency-modulation AFM (FM-AFM), which utilizes three feedback loops to control the cantilever excitation amplitude, cantilever excitation frequency, and z-piezo extension. These loops are regulated by a set of feedback parameters, tuned by the user to optimize stability, sensitivity, and noise in the imaging process. Optimization of these parameters is difficult due to the coupling between the frequency and z-piezo feedback loops by the non-linear tip-sample interaction. Four proportional-integral (PI) parameters and two lock-in parameters regulating these loops require simultaneous optimization in the presence of a varying unknown tip-sample coupling. Presently, this optimization is done manually in a tedious process of trial and error. Here, we report on the development and implementation of an algorithm that computes the control parameters automatically. The algorithm reads the unperturbed cantilever resonance frequency, its quality factor, and the z-piezo driving signal power spectral density. It analyzes the poles and zeros of the total closed loop transfer function, extracts the unknown tip-sample transfer function, and finds four PI parameters and two lock-in parameters for the frequency and z-piezo control loops that optimize the bandwidth and step response of the total system. Implementation of the algorithm in a home-built AFM shows that the calculated parameters are consistently excellent and rarely require further tweaking by the user. The new algorithm saves the precious time of experienced users, facilitates utilization of FM-AFM by casual users, and removes the main hurdle on the way to fully automated FM-AFM.

  7. Autopilot for frequency-modulation atomic force microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuchuk, Kfir; Schlesinger, Itai; Sivan, Uri, E-mail: phsivan@tx.technion.ac.il

    2015-10-15

    One of the most challenging aspects of operating an atomic force microscope (AFM) is finding optimal feedback parameters. This statement applies particularly to frequency-modulation AFM (FM-AFM), which utilizes three feedback loops to control the cantilever excitation amplitude, cantilever excitation frequency, and z-piezo extension. These loops are regulated by a set of feedback parameters, tuned by the user to optimize stability, sensitivity, and noise in the imaging process. Optimization of these parameters is difficult due to the coupling between the frequency and z-piezo feedback loops by the non-linear tip-sample interaction. Four proportional-integral (PI) parameters and two lock-in parameters regulating these loopsmore » require simultaneous optimization in the presence of a varying unknown tip-sample coupling. Presently, this optimization is done manually in a tedious process of trial and error. Here, we report on the development and implementation of an algorithm that computes the control parameters automatically. The algorithm reads the unperturbed cantilever resonance frequency, its quality factor, and the z-piezo driving signal power spectral density. It analyzes the poles and zeros of the total closed loop transfer function, extracts the unknown tip-sample transfer function, and finds four PI parameters and two lock-in parameters for the frequency and z-piezo control loops that optimize the bandwidth and step response of the total system. Implementation of the algorithm in a home-built AFM shows that the calculated parameters are consistently excellent and rarely require further tweaking by the user. The new algorithm saves the precious time of experienced users, facilitates utilization of FM-AFM by casual users, and removes the main hurdle on the way to fully automated FM-AFM.« less

  8. Non-Uniform Sampling and J-UNIO Automation for Efficient Protein NMR Structure Determination.

    PubMed

    Didenko, Tatiana; Proudfoot, Andrew; Dutta, Samit Kumar; Serrano, Pedro; Wüthrich, Kurt

    2015-08-24

    High-resolution structure determination of small proteins in solution is one of the big assets of NMR spectroscopy in structural biology. Improvements in the efficiency of NMR structure determination by advances in NMR experiments and automation of data handling therefore attracts continued interest. Here, non-uniform sampling (NUS) of 3D heteronuclear-resolved [(1)H,(1)H]-NOESY data yielded two- to three-fold savings of instrument time for structure determinations of soluble proteins. With the 152-residue protein NP_372339.1 from Staphylococcus aureus and the 71-residue protein NP_346341.1 from Streptococcus pneumonia we show that high-quality structures can be obtained with NUS NMR data, which are equally well amenable to robust automated analysis as the corresponding uniformly sampled data. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Automated diagnostic kiosk for diagnosing diseases

    DOEpatents

    Regan, John Frederick; Birch, James Michael

    2014-02-11

    An automated and autonomous diagnostic apparatus that is capable of dispensing collection vials and collections kits to users interesting in collecting a biological sample and submitting their collected sample contained within a collection vial into the apparatus for automated diagnostic services. The user communicates with the apparatus through a touch-screen monitor. A user is able to enter personnel information into the apparatus including medical history, insurance information, co-payment, and answer a series of questions regarding their illness, which is used to determine the assay most likely to yield a positive result. Remotely-located physicians can communicate with users of the apparatus using video tele-medicine and request specific assays to be performed. The apparatus archives submitted samples for additional testing. Users may receive their assay results electronically. Users may allow the uploading of their diagnoses into a central databank for disease surveillance purposes.

  10. Use of one-ply composite tissues in an automated optical assay for recovery of Listeria from food contact surfaces and poultry-processing environments.

    PubMed

    Yan, Zhinong; Vorst, Keith L; Zhang, Lei; Ryser, Elliot T

    2007-05-01

    A novel one-ply composite tissue (CT) method using the Soleris (formerly BioSys) optical analysis system was compared with the conventional U.S. Department of Agriculture (USDA) environmental sponge enrichment method for recovery of Listeria from food contact surfaces and poultry-processing environments. Stainless steel and high-density polyethylene plates were inoculated to contain a six-strain L. monocytogenes cocktail at 10(4), 10(2), and 10 CFU per plate, whereas samples from naturally contaminated surfaces and floor drains from a poultry-processing facility were collected with CTs and environmental sponges. CT samples were transferred into Soleris system vials, and presumptive-positive samples were further confirmed. Sponge samples were processed for Listeria using the USDA culture method. L. monocytogenes recovery rates from inoculated stainless steel and polyethylene surfaces were then compared for the two methods in terms of sensitivity, specificity, and positive and negative predictive values. No significant differences (P > 0.05) were found between the two methods for recovery of L. monocytogenes from any of the inoculated stainless steel and polyethylene surfaces or environmental samples. Sensitivity, specificity, and overall accuracy of the CT-Soleris for recovery of Listeria from environmental samples were 83, 97, and 95%, respectively. Listeria was detected 2 to 3 days sooner with the CT-Soleris method than with the USDA culture method, thus supporting the increased efficacy of this new protocol for environmental sampling.

  11. Peripheral refractive correction and automated perimetric profiles.

    PubMed

    Wild, J M; Wood, J M; Crews, S J

    1988-06-01

    The effect of peripheral refractive error correction on the automated perimetric sensitivity profile was investigated on a sample of 10 clinically normal, experienced observers. Peripheral refractive error was determined at eccentricities of 0 degree, 20 degrees and 40 degrees along the temporal meridian of the right eye using the Canon Autoref R-1, an infra-red automated refractor, under the parametric conditions of the Octopus automated perimeter. Perimetric sensitivity was then undertaken at these eccentricities (stimulus sizes 0 and III) with and without the appropriate peripheral refractive correction using the Octopus 201 automated perimeter. Within the measurement limits of the experimental procedures employed, perimetric sensitivity was not influenced by peripheral refractive correction.

  12. Dual-Use Space Technology Transfer Conference and Exhibition. Volume 1

    NASA Technical Reports Server (NTRS)

    Krishen, Kumar (Compiler)

    1994-01-01

    This document contains papers presented at the Dual-Use Space Technology Transfer Conference and Exhibition held at the Johnson Space Center February 1-3, 1994. Possible technology transfers covered during the conference were in the areas of information access; innovative microwave and optical applications; materials and structures; marketing and barriers; intelligent systems; human factors and habitation; communications and data systems; business process and technology transfer; software engineering; biotechnology and advanced bioinstrumentation; communications signal processing and analysis; new ways of doing business; medical care; applications derived from control center data systems; human performance evaluation; technology transfer methods; mathematics, modeling, and simulation; propulsion; software analysis and decision tools systems/processes in human support technology; networks, control centers, and distributed systems; power; rapid development perception and vision technologies; integrated vehicle health management; automation technologies; advanced avionics; ans robotics technologies. More than 77 papers, 20 presentations, and 20 exhibits covering various disciplines were presented b experts from NASA, universities, and industry.

  13. Oak ridge national laboratory automated clean chemistry for bulk analysis of environmental swipe samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bostick, Debra A.; Hexel, Cole R.; Ticknor, Brian W.

    2016-11-01

    To shorten the lengthy and costly manual chemical purification procedures, sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment. This addresses a serious need in the nuclear safeguards community to debottleneck the separation of U and Pu in environmental samples—currently performed by overburdened chemists—with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc., the prepFAST-MC2 was designed based on current COTS equipment that was modified for U/Pu separations utilizing Eichrom™ TEVA and UTEVA resins. Initial verification of individual columns yielded small elution volumes with consistent elution profiles and good recovery. Combined columnmore » calibration demonstrated ample separation without crosscontamination of the eluent. Automated packing and unpacking of the built-in columns initially showed >15% deviation in resin loading by weight, which can lead to inconsistent separations. Optimization of the packing and unpacking methods led to a reduction in the variability of the packed resin to less than 5% daily. The reproducibility of the automated system was tested with samples containing 30 ng U and 15 pg Pu, which were separated in a series with alternating reagent blanks. These experiments showed very good washout of both the resin and the sample from the columns as evidenced by low blank values. Analysis of the major and minor isotope ratios for U and Pu provided values well within data quality limits for the International Atomic Energy Agency. Additionally, system process blanks spiked with 233U and 244Pu tracers were separated using the automated system after it was moved outside of a clean room and yielded levels equivalent to clean room blanks, confirming that the system can produce high quality results without the need for expensive clean room infrastructure. Comparison of the amount of personnel time necessary for successful manual vs. automated chemical separations showed a significant decrease in hands-on time from 9.8 hours to 35 minutes for seven samples, respectively. This documented time savings and reduced labor translates to a significant cost savings per sample. Overall, the system will enable faster sample reporting times at reduced costs by limiting personnel hours dedicated to the chemical separation.« less

  14. Contamination analyses of technology mirror assembly optical surfaces

    NASA Technical Reports Server (NTRS)

    Germani, Mark S.

    1991-01-01

    Automated electron microprobe analyses were performed on tape lift samples from the Technology Mirror Assembly (TMA) optical surfaces. Details of the analyses are given, and the contamination of the mirror surfaces is discussed. Based on the automated analyses of the tape lifts from the TMA surfaces and the control blank, we can conclude that the particles identified on the actual samples were not a result of contamination due to the handling or sampling process itself and that the particles reflect the actual contamination on the surface of the mirror.

  15. Human mixed lymphocyte cultures. Evaluation of microculture technique utilizing the multiple automated sample harvester (MASH)

    PubMed Central

    Thurman, G. B.; Strong, D. M.; Ahmed, A.; Green, S. S.; Sell, K. W.; Hartzman, R. J.; Bach, F. H.

    1973-01-01

    Use of lymphocyte cultures for in vitro studies such as pretransplant histocompatibility testing has established the need for standardization of this technique. A microculture technique has been developed that has facilitated the culturing of lymphocytes and increased the quantity of cultures feasible, while lowering the variation between replicate samples. Cultures were prepared for determination of tritiated thymidine incorporation using a Multiple Automated Sample Harvester (MASH). Using this system, the parameters that influence the in vitro responsiveness of human lymphocytes to allogeneic lymphocytes have been investigated. PMID:4271568

  16. The Automation-by-Expertise-by-Training Interaction.

    PubMed

    Strauch, Barry

    2017-03-01

    I introduce the automation-by-expertise-by-training interaction in automated systems and discuss its influence on operator performance. Transportation accidents that, across a 30-year interval demonstrated identical automation-related operator errors, suggest a need to reexamine traditional views of automation. I review accident investigation reports, regulator studies, and literature on human computer interaction, expertise, and training and discuss how failing to attend to the interaction of automation, expertise level, and training has enabled operators to commit identical automation-related errors. Automated systems continue to provide capabilities exceeding operators' need for effective system operation and provide interfaces that can hinder, rather than enhance, operator automation-related situation awareness. Because of limitations in time and resources, training programs do not provide operators the expertise needed to effectively operate these automated systems, requiring them to obtain the expertise ad hoc during system operations. As a result, many do not acquire necessary automation-related system expertise. Integrating automation with expected operator expertise levels, and within training programs that provide operators the necessary automation expertise, can reduce opportunities for automation-related operator errors. Research to address the automation-by-expertise-by-training interaction is needed. However, such research must meet challenges inherent to examining realistic sociotechnical system automation features with representative samples of operators, perhaps by using observational and ethnographic research. Research in this domain should improve the integration of design and training and, it is hoped, enhance operator performance.

  17. Automated processing of forensic casework samples using robotic workstations equipped with nondisposable tips: contamination prevention.

    PubMed

    Frégeau, Chantal J; Lett, C Marc; Elliott, Jim; Yensen, Craig; Fourney, Ron M

    2008-05-01

    An automated process has been developed for the analysis of forensic casework samples using TECAN Genesis RSP 150/8 or Freedom EVO liquid handling workstations equipped exclusively with nondisposable tips. Robot tip cleaning routines have been incorporated strategically within the DNA extraction process as well as at the end of each session. Alternative options were examined for cleaning the tips and different strategies were employed to verify cross-contamination. A 2% sodium hypochlorite wash (1/5th dilution of the 10.8% commercial bleach stock) proved to be the best overall approach for preventing cross-contamination of samples processed using our automated protocol. The bleach wash steps do not adversely impact the short tandem repeat (STR) profiles developed from DNA extracted robotically and allow for major cost savings through the implementation of fixed tips. We have demonstrated that robotic workstations equipped with fixed pipette tips can be used with confidence with properly designed tip washing routines to process casework samples using an adapted magnetic bead extraction protocol.

  18. UV LED lighting for automated crystal centring

    PubMed Central

    Chavas, Leonard M. G.; Yamada, Yusuke; Hiraki, Masahiko; Igarashi, Noriyuki; Matsugaki, Naohiro; Wakatsuki, Soichi

    2011-01-01

    A direct outcome of the exponential growth of macromolecular crystallography is the continuously increasing demand for synchrotron beam time, both from academic and industrial users. As more and more projects entail screening a profusion of sample crystals, fully automated procedures at every level of the experiments are being implemented at all synchrotron facilities. One of the major obstacles to achieving such automation lies in the sample recognition and centring in the X-ray beam. The capacity of UV light to specifically react with aromatic residues present in proteins or with DNA base pairs is at the basis of UV-assisted crystal centring. Although very efficient, a well known side effect of illuminating biological samples with strong UV sources is the damage induced on the irradiated samples. In the present study the effectiveness of a softer UV light for crystal centring by taking advantage of low-power light-emitting diode (LED) sources has been investigated. The use of UV LEDs represents a low-cost solution for crystal centring with high specificity. PMID:21169682

  19. ATV-4 approach to ISS

    NASA Image and Video Library

    2013-06-15

    ISS036-E-008169 (15 June 2013) --- The European Space Agency's Automated Transfer Vehicle-4 (ATV-4) “Albert Einstein” approaches the International Space Station. The spacecraft went on to successfully dock to the orbital outpost at 2:07 GMT, June 15, 2013, following a ten-day period of free-flight.

  20. ESA Albert Einstein ATV-4 during approach

    NASA Image and Video Library

    2013-06-15

    ISS036-E-007858 (15 June 2013) --- The European Space Agency's Automated Transfer Vehicle-4 (ATV-4) “Albert Einstein” approaches the International Space Station. The spacecraft went on to successfully dock to the orbital outpost at 2:07 GMT, June 15, 2013, following a ten-day period of free-flight.

  1. ATV-4 approach to ISS

    NASA Image and Video Library

    2013-06-15

    ISS036-E-008170 (15 June 2013) --- The European Space Agency's Automated Transfer Vehicle-4 (ATV-4) “Albert Einstein” approaches the International Space Station. The spacecraft went on to successfully dock to the orbital outpost at 2:07 GMT, June 15, 2013, following a ten-day period of free-flight.

  2. ESA Albert Einstein ATV-4 during approach

    NASA Image and Video Library

    2013-06-15

    ISS036-E-007856 (15 June 2013) --- The European Space Agency's Automated Transfer Vehicle-4 (ATV-4) “Albert Einstein” approaches the International Space Station. The spacecraft went on to successfully dock to the orbital outpost at 2:07 GMT, June 15, 2013, following a ten-day period of free-flight.

  3. ESA Albert Einstein ATV-4 during approach

    NASA Image and Video Library

    2013-06-15

    ISS036-E-007864 (15 June 2013) --- As seen from a window in the Pirs module, the European Space Agency's Automated Transfer Vehicle-4 (ATV-4) “Albert Einstein” is about to dock to the orbital outpost at 2:07 GMT, June 15, 2013, following a ten-day period of free-flight.

  4. New Technology and the Public Library. Final Report and Executive Summary.

    ERIC Educational Resources Information Center

    Griffiths, Jose-Marie; King, Donald W.

    This report presents current and potential library applications of new technologies, issues surrounding their introduction into public libraries, and activities suggested for use during the introduction procedure. A brief appraisal of the public library's role in the information transfer process precedes a review of library automation in…

  5. Volkov and Kononenko with the stowage bags in the ATV during Expedition 17

    NASA Image and Video Library

    2008-05-12

    ISS017-E-006545 (12 May 2008) --- Russian Federal Space Agency cosmonauts Sergei Volkov (left), Expedition 17 commander, and Oleg Kononenko, flight engineer, work with stowage bags in the Jules Verne Automated Transfer Vehicle (ATV) while it remains docked with the International Space Station.

  6. Stott and Barratt in ATV-2

    NASA Image and Video Library

    2011-02-26

    S133-E-006555 (26 Feb. 2011) --- NASA astronauts Nicole Stott and Michael Barratt, both STS-133 mission specialists, are pictured in the European Space Agency's "Johannes Kepler" Automated Transfer Vehicle-2 (ATV-2) currently docked to the International Space Station. Photo credit: NASA or National Aeronautics and Space Administration

  7. Kuipers and Kononenko during ATV Approach and Docking

    NASA Image and Video Library

    2012-03-28

    ISS030-E-177327 (28 March 2012) --- European Space Agency astronaut Andre Kuipers and Russian cosmonaut Oleg Kononenko (foreground), both Expedition 30 flight engineers, monitor the approach and docking of ESA’s “Edoardo Amaldi” Automated Transfer Vehicle-3 (ATV-3) in the Zvezda Service Module of the International Space Station.

  8. ATV 2 Approach

    NASA Image and Video Library

    2011-02-24

    ISS026-E-029343 (24 Feb. 2011) --- Backdropped by the blackness of space and Earth’s horizon, the European Space Agency's "Johannes Kepler" Automated Transfer Vehicle-2 (ATV-2) appears very small as it approaches the International Space Station. Docking of the two spacecraft occurred at 10:59 a.m. (EST) on Feb. 24, 2011.

  9. External view of ISS

    NASA Image and Video Library

    2014-09-02

    ISS040-E-123171 (2 Sept. 2014) --- A portion of the International Space Station’s Russian segment is pictured in this image photographed by an Expedition 40 crew member onboard the station. A portion of the "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5) docked to the Zvezda Service Module is visible at right background.

  10. External view of ISS

    NASA Image and Video Library

    2014-09-02

    ISS040-E-123168 (2 Sept. 2014) --- A portion of the International Space Station’s Russian segment is pictured in this image photographed by an Expedition 40 crew member onboard the station. A portion of the "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5) docked to the Zvezda Service Module is visible at right background.

  11. Supermoon setting behind ATV

    NASA Image and Video Library

    2014-08-12

    ISS040-E-092581 (12 Aug. 2014) --- A portion of the International Space Station?s Zvezda Service Module with the newly attached "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5) is featured in this image photographed by an Expedition 40 crew member onboard the station. A waning full moon is visible in the background.

  12. ATV 2 Johannes Kepler docked

    NASA Image and Video Library

    2011-02-24

    ISS026-E-029294 (24 Feb. 2011) --- Backdropped by the blackness of space, the European Space Agency's "Johannes Kepler" Automated Transfer Vehicle-2 (ATV-2) docks to the aft end of the International Space Station's Zvezda Service Module. Docking of the two spacecraft occurred at 10:59 a.m. (EST) on Feb. 24, 2011.

  13. Kuipers and Kononenko during ATV Approach and Docking

    NASA Image and Video Library

    2012-03-28

    ISS030-E-177363 (28 March 2012) --- European Space Agency astronaut Andre Kuipers and Russian cosmonaut Oleg Kononenko (foreground), both Expedition 30 flight engineers, monitor the approach and docking of ESA’s “Edoardo Amaldi” Automated Transfer Vehicle-3 (ATV-3) in the Zvezda Service Module of the International Space Station.

  14. Kuipers and Kononenko during ATV Approach and Docking

    NASA Image and Video Library

    2012-03-28

    ISS030-E-177317 (28 March 2012) --- European Space Agency astronaut Andre Kuipers and Russian cosmonaut Oleg Kononenko (foreground), both Expedition 30 flight engineers, monitor the approach and docking of ESA’s “Edoardo Amaldi” Automated Transfer Vehicle-3 (ATV-3) in the Zvezda Service Module of the International Space Station.

  15. Evaluation of cell count and classification capabilities in body fluids using a fully automated Sysmex XN equipped with high-sensitive Analysis (hsA) mode and DI-60 hematology analyzer system.

    PubMed

    Takemura, Hiroyuki; Ai, Tomohiko; Kimura, Konobu; Nagasaka, Kaori; Takahashi, Toshihiro; Tsuchiya, Koji; Yang, Haeun; Konishi, Aya; Uchihashi, Kinya; Horii, Takashi; Tabe, Yoko; Ohsaka, Akimichi

    2018-01-01

    The XN series automated hematology analyzer has been equipped with a body fluid (BF) mode to count and differentiate leukocytes in BF samples including cerebrospinal fluid (CSF). However, its diagnostic accuracy is not reliable for CSF samples with low cell concentration at the border between normal and pathologic level. To overcome this limitation, a new flow cytometry-based technology, termed "high sensitive analysis (hsA) mode," has been developed. In addition, the XN series analyzer has been equipped with the automated digital cell imaging analyzer DI-60 to classify cell morphology including normal leukocytes differential and abnormal malignant cells detection. Using various BF samples, we evaluated the performance of the XN-hsA mode and DI-60 compared to manual microscopic examination. The reproducibility of the XN-hsA mode showed good results in samples with low cell densities (coefficient of variation; % CV: 7.8% for 6 cells/μL). The linearity of the XN-hsA mode was established up to 938 cells/μL. The cell number obtained using the XN-hsA mode correlated highly with the corresponding microscopic examination. Good correlation was also observed between the DI-60 analyses and manual microscopic classification for all leukocyte types, except monocytes. In conclusion, the combined use of cell counting with the XN-hsA mode and automated morphological analyses using the DI-60 mode is potentially useful for the automated analysis of BF cells.

  16. Development of software and hardware models of monitoring, control, and data transfer to improve safety of downhole motor during drilling

    NASA Astrophysics Data System (ADS)

    Kostarev, S. N.; Sereda, T. G.

    2017-10-01

    The article is concerned with the problem of transmitting data from telemetric devices in order to provide automated systems for the electric drive control of oil-extracting equipment. The paper given discusses the possibility to use a logging cable as means of signal transfer. Simulation models of signaling and relay-contact circuits for monitoring critical drive parameters are under discussion. The authors suggest applying the operator ⊕ (excluding OR) to increase anti-jamming effects and to get a more reliable noise filter.

  17. Improving management decision processes through centralized communication linkages

    NASA Technical Reports Server (NTRS)

    Simanton, D. F.; Garman, J. R.

    1985-01-01

    Information flow is a critical element to intelligent and timely decision-making. At NASA's Johnson Space Center the flow of information is being automated through the use of a centralized backbone network. The theoretical basis of this network, its implications to the horizontal and vertical flow of information, and the technical challenges involved in its implementation are the focus of this paper. The importance of the use of common tools among programs and some future concerns related to file transfer, graphics transfer, and merging of voice and data are also discussed.

  18. Perl Embedded in PTC's Pro/ENGINEER, Version 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2003-12-22

    Pro-PERL (AKA Pro/PERL) is a Perl extension to the PTC Pro/TOOLKIT API to the PTC Pro/ENGINEER CAD application including an embedded interpreter. It can be used to automate and customize Pro/ENGINEER, create Vendor Neutral Archive (VNA) format files and re-create CAD models from the VNA files. This has applications in sanitizing classified CAD models created in a classified environment for transfer to an open environment, creating template models for modification to finished models by non-expert users, and transfer of design intent data to other modeling technologies.

  19. Design and implementation of an automated email notification system for results of tests pending at discharge.

    PubMed

    Dalal, Anuj K; Schnipper, Jeffrey L; Poon, Eric G; Williams, Deborah H; Rossi-Roh, Kathleen; Macleay, Allison; Liang, Catherine L; Nolido, Nyryan; Budris, Jonas; Bates, David W; Roy, Christopher L

    2012-01-01

    Physicians are often unaware of the results of tests pending at discharge (TPADs). The authors designed and implemented an automated system to notify the responsible inpatient physician of the finalized results of TPADs using secure, network email. The system coordinates a series of electronic events triggered by the discharge time stamp and sends an email to the identified discharging attending physician once finalized results are available. A carbon copy is sent to the primary care physicians in order to facilitate communication and the subsequent transfer of responsibility. Logic was incorporated to suppress selected tests and to limit notification volume. The system was activated for patients with TPADs discharged by randomly selected inpatient-attending physicians during a 6-month pilot. They received approximately 1.6 email notifications per discharged patient with TPADs. Eighty-four per cent of inpatient-attending physicians receiving automated email notifications stated that they were satisfied with the system in a brief survey (59% survey response rate). Automated email notification is a useful strategy for managing results of TPADs.

  20. Wireless energizing system for an automated implantable sensor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swain, Biswaranjan; Nayak, Praveen P.; Kar, Durga P.

    The wireless drive of an automated implantable electronic sensor has been explored for health monitoring applications. The proposed system comprises of an automated biomedical sensing system which is energized through resonant inductive coupling. The implantable sensor unit is able to monitor the body temperature parameter and sends back the corresponding telemetry data wirelessly to the data recoding unit. It has been observed that the wireless power delivery system is capable of energizing the automated biomedical implantable electronic sensor placed over a distance of 3 cm from the power transmitter with an energy transfer efficiency of 26% at the operating resonantmore » frequency of 562 kHz. This proposed method ensures real-time monitoring of different human body temperatures around the clock. The monitored temperature data have been compared with a calibrated temperature measurement system to ascertain the accuracy of the proposed system. The investigated technique can also be useful for monitoring other body parameters such as blood pressure, bladder pressure, and physiological signals of the patient in vivo using various implantable sensors.« less