Sample records for automatic blood sampling

  1. Cerebral Oxygenation and Pain of Heel Blood Sampling Using Manual and Automatic Lancets in Premature Infants.

    PubMed

    Hwang, Mi-Jung; Seol, Geun Hee

    2015-01-01

    Heel blood sampling is a common but painful procedure for neonates. Automatic lancets have been shown to be more effective, with reduced pain and tissue damage, than manual lancets, but the effects of lancet type on cortical activation have not yet been compared. The study aimed to compare the effects of manual and automatic lancets on cerebral oxygenation and pain of heel blood sampling in 24 premature infants with respiratory distress syndrome. Effectiveness was measured by assessing numbers of pricks and squeezes and duration of heel blood sampling. Pain responses were measured using the premature infant pain profile score, heart rate, and oxygen saturation (SpO2). Regional cerebral oxygen saturation (rScO2) was measured using near-infrared spectroscopy, and cerebral fractional tissue oxygen extraction was calculated from SpO2 and rScO. Measures of effectiveness were significantly better with automatic than with manual lancing, including fewer heel punctures (P = .009) and squeezes (P < .001) and shorter duration of heel blood sampling (P = .002). rScO2 was significantly higher (P = .013) and cerebral fractional tissue oxygen extraction after puncture significantly lower (P = .040) with automatic lancing. Premature infant pain profile scores during (P = .004) and after (P = .048) puncture were significantly lower in the automatic than in the manual lancet group. Automatic lancets for heel blood sampling in neonates with respiratory distress syndrome significantly reduced pain and enhanced cerebral oxygenation, suggesting that heel blood should be sampled routinely using an automatic lancet.

  2. An Automatic Lab-on-Disc System for Blood Typing.

    PubMed

    Chang, Yaw-Jen; Fan, Yi-Hua; Chen, Shia-Chung; Lee, Kuan-Hua; Lou, Liao-Yong

    2018-04-01

    A blood-typing assay is a critical test to ensure the serological compatibility of a donor and an intended recipient prior to a blood transfusion. This article presents a lab-on-disc blood-typing system to conduct a total of eight assays for a patient, including forward-typing tests, reverse-typing tests, and irregular-antibody tests. These assays are carried out in a microfluidic disc simultaneously. A blood-typing apparatus was designed to automatically manipulate the disc. The blood type can be determined by integrating the results of red blood cell (RBC) agglutination in the microchannels. The experimental results of our current 40 blood samples show that the results agree with those examined in the hospital. The accuracy reaches 97.5%.

  3. In situ control of cardiotomy suction reduces blood trauma.

    PubMed

    Tevaearai, H T; Mueller, X M; Horisberger, J; Augstburger, M; Bock, H; Knorr, A; von Segesser, L K

    1998-01-01

    Cardiotomy suction is known for its deleterious effects on formed and unformed blood elements. The authors investigated an "intelligent" remote controlled automatic suction system. A suction cannula with an optic sensor at its tip was connected to a special closed cardiotomy reservoir. Contact with blood immediately generated a reservoir vacuum from 0 to -100 mmHg, permitting aspiration until the blood was no longer detected (automatic shut off). Blood trauma was evaluated in a bovine model, comparing the automatic suction system vs standard continuous aspiration (control) adjusted to -100 mmHg. After full systemic heparinization, five calves (weight, 62.5 +/- 4.4 kg) for the automatic suction system group, and four (weight, 62.8 +/- 5.1 kg) for the control group, were equipped with a jugular cannula connected via a roller pump to the cardiotomy reservoir. Through a small thoracotomy, a standardized hole was created in the right atrium, allowing for a blood loss of approximately 400 ml/min. The suction cannula was placed into the chest cavity in a fixed position. Blood samples were drawn at regular intervals for cell count and chemistry. Lactate dehydrogenase values, for the automatic suction system and the control groups, respectively, expressed as percent of baseline value, were 88 +/- 14 vs 116 +/- 22 after 1 hr; 94 +/- 16 vs 123 +/- 23 after 2 hr; and 97 +/- 19 vs 140 +/- 48 after 3 hr (p < 0.05). Values for free hemoglobin in plasma (percent of baseline value), for the automatic suction system and the control groups, respectively, were 102 +/- 18 vs 200 +/- 69 after 1 hr; 98 +/- 29 vs 163 +/- 37 after 2 hr; and 94 +/- 37 vs 179 +/- 42 after 3 hr (p < 0.05). Compared with a standard continuous aspiration system, in situ regulation of suction significantly reduces blood trauma.

  4. Kit for the rapid preparation of .sup.99m Tc red blood cells

    DOEpatents

    Richards, Powell; Smith, Terry D.

    1976-01-01

    A method and sample kit for the preparation of .sup.99m Tc-labeled red blood cells in a closed, sterile system. A partially evacuated tube, containing a freeze-dried stannous citrate formulation with heparin as an anticoagulant, allows whole blood to be automatically drawn from the patient. The radioisotope is added at the end of the labeling sequence to minimize operator exposure. Consistent 97% yields in 20 minutes are obtained with small blood samples. Freeze-dried kits have remained stable after five months.

  5. Automation of a flocculation test for syphilis on Groupamatic equipment.

    PubMed Central

    Garretta, M; Paris-Hamelin, A; Gener, J; Muller, A; Matte, C; Vaisman, A

    1975-01-01

    A flocculation reaction employing a cardiolipid antigen was used for syphilis screening on Groupamatic equipment in parallel with conventional screening reactions: Kolmer CF, RPCF, Kahn, Kline, and RPR. The positive samples were confirmed by FTA-200, FTA-ABS, TPI, and in some cases by TPHA. There were 5,212 known samples which had already been tested by all methods and of which 1,648 were positive, and 58,636 screened samples including 65 positives. Half of the samples in the first series were taken without anticoagulant; the remainder were collected in potassium EDTA. The percentage of false positives with the Groupamatic was about 1-4 per cent. The percentage of false negatives among positve (greater than or equal+) samples varied from 0-18 to 1-3 per cent.; on the other hand the sensitivity was less good for samples giving doubtful and/or dissociated reactions in conventional screening reactions. The specificity and sensitivity of this technique are acceptable for a blood transfusion centre. The reproducibility is excellent and the automatic reading of results accurate. Additional advantages are rapidity (340 samples processed per hour); simultaneous performance of eleven other immunohaematological reactions; no contamination between samples; automatic reading, interpretation, and print-out of results; and saving of time because samples are not filed sequentially and are automatically identified when the results are obtained. Although the importance of syphilis in blood transfusion seems small, estimates of the risk are difficult and further investigations are planned. Images PMID:1098731

  6. Fragmentation of Red Blood Cells Caused Pseudothrombocytosis in a Patient.

    PubMed

    Tang, Wenjun; Tang, Chunhua; Zheng, Jianfeng; He, Yongling; Lu, Fangfang

    2018-06-01

    Pseudothrombocytopenia, caused by platelet (PLT) clumping, is often found in clinical studies [1]. However, pseudothrombocytosis resulting from the fragmentation of red blood cells (RBCs) is a very rare phenomenon. EDTA-K2 anticoagulation was used on a sample of venous blood extracted from the patient. A Symex XN9000 automatic blood analyzer was used to conduct CBC + DIFF mode and CBC + DIFF + RET mode tests, stained smear microscopy. The Symex XN9000 automatic blood analyzer was used to conduct CBC + DIFF mode test; PLTs were measured at 570 x 109/L. Stained smear microscopy revealed the number of PLTs did not conform to the instrument measured 570 x 109/L. "RET" alarm instrument, switch to CBC + DIFF + RET mode for testing. The second test result showed PLTs at 128 x 109/L, which accords with artificial microscopy. This was a case of a very rare phenomenon: the fragmentation of RBCs caused pseudothrombocytosis.

  7. Development of portable health monitoring system for automatic self-blood glucose measurement

    NASA Astrophysics Data System (ADS)

    Kim, Huijun; Mizuno, Yoshihumi; Nakamachi, Eiji; Morita, Yusuke

    2010-02-01

    In this study, a new HMS (Health Monitoring System) device is developed for diabetic patient. This device mainly consists of I) 3D blood vessel searching unit and II) automatic blood glucose measurement (ABGM) unit. This device has features such as 1)3D blood vessel location search 2) laptop type, 3) puncturing a blood vessel by using a minimally invasive micro-needle, 4) very little blood sampling (10μl), and 5) automatic blood extraction and blood glucose measurement. In this study, ABGM unit is described in detail. It employs a syringe type's blood extraction mechanism because of its high accuracy. And it consists of the syringe component and the driving component. The syringe component consists of a syringe itself, a piston, a magnet, a ratchet and a micro-needle whose inner diameter is about 80μm. And the syringe component is disposable. The driving component consists of body parts, a linear stepping motor, a glucose enzyme sensor and a slider for accurate positioning control. The driving component has the all-in-one mechanism with a glucose enzyme sensor for compact size and stable blood transfer. On designing, required thrust force to drive the slider is designed to be greater than the value of the blood extraction force. Further, only one linear stepping motor is employed for blood extraction and transportation processes. The experimental result showed more than 80% of volume ratio under the piston speed 2.4mm/s. Further, the blood glucose was measured successfully by using the prototype unit. Finally, the availability of our ABGM unit was confirmed.

  8. A case of perioperative glucose control by using an artificial pancreas in a patient with glycogen storage disease.

    PubMed

    Yatabe, Tomoaki; Nakamura, Ryu; Kitagawa, Hiroyuki; Munekage, Masaya; Hanazaki, Kazuhiro

    2016-03-01

    A 57-year-old woman was diagnosed with type I glycogen storage disease in her twenties. She had undergone hepatectomy under general anesthesia with epidural anesthesia. Fifty minutes after the induction of anesthesia, a 20-gauge venous catheter was inserted in the patient's right hand, and an artificial pancreas (STG-55, Nikkiso Co., Tokyo, Japan) was connected for continuous glucose monitoring and automatic glucose control. Insulin was infused when the blood glucose level reached 120 mg/dL or higher, and glucose was infused when the level fell to 100 mg/dL or lower. After the Pringle maneuver, the blood glucose level increased, and insulin was administered automatically via an artificial pancreas. Hypoglycemia did not occur during the operation. After total parenteral nutrition was started in the intensive care unit (ICU), the blood glucose level increased, and the artificial pancreas controlled the blood glucose level through automatic insulin administration. Thirty-four hours after admission to the ICU, the artificial pancreas was removed because the blood sampling failed. After the removal of the artificial pancreas, blood glucose level was measured every 2 h until extubation. During the ICU stay, hypoglycemia never occurred, with the average blood glucose level being 144 mg/dL. In conclusion, the use of an artificial pancreas for perioperative blood glucose management in a patient with glycogen storage disease had the beneficial effect of enabling the management of blood glucose levels without hypoglycemia.

  9. Patient safety with blood products administration using wireless and bar-code technology.

    PubMed

    Porcella, Aleta; Walker, Kristy

    2005-01-01

    Supported by a grant from the Agency for Healthcare Research and Quality, a University of Iowa Hospitals and Clinics interdisciplinary research team created an online data-capture-response tool utilizing wireless mobile devices and bar code technology to track and improve blood products administration process. The tool captures 1) sample collection, 2) sample arrival in the blood bank, 3) blood product dispense from blood bank, and 4) administration. At each step, the scanned patient wristband ID bar code is automatically compared to scanned identification barcode on requisition, sample, and/or product, and the system presents either a confirmation or an error message to the user. Following an eight-month, 5 unit, staged pilot, a 'big bang,' hospital-wide implementation occurred on February 7, 2005. Preliminary results from pilot data indicate that the new barcode process captures errors 3 to 10 times better than the old manual process.

  10. Automatic classification of atypical lymphoid B cells using digital blood image processing.

    PubMed

    Alférez, S; Merino, A; Mujica, L E; Ruiz, M; Bigorra, L; Rodellar, J

    2014-08-01

    There are automated systems for digital peripheral blood (PB) cell analysis, but they operate most effectively in nonpathological blood samples. The objective of this work was to design a methodology to improve the automatic classification of abnormal lymphoid cells. We analyzed 340 digital images of individual lymphoid cells from PB films obtained in the CellaVision DM96:150 chronic lymphocytic leukemia (CLL) cells, 100 hairy cell leukemia (HCL) cells, and 90 normal lymphocytes (N). We implemented the Watershed Transformation to segment the nucleus, the cytoplasm, and the peripheral cell region. We extracted 44 features and then the clustering Fuzzy C-Means (FCM) was applied in two steps for the lymphocyte classification. The images were automatically clustered in three groups, one of them with 98% of the HCL cells. The set of the remaining cells was clustered again using FCM and texture features. The two new groups contained 83.3% of the N cells and 71.3% of the CLL cells, respectively. The approach has been able to automatically classify with high precision three types of lymphoid cells. The addition of more descriptors and other classification techniques will allow extending the classification to other classes of atypical lymphoid cells. © 2013 John Wiley & Sons Ltd.

  11. Liquid chromatography-mass spectrometry platform for both small neurotransmitters and neuropeptides in blood, with automatic and robust solid phase extraction

    NASA Astrophysics Data System (ADS)

    Johnsen, Elin; Leknes, Siri; Wilson, Steven Ray; Lundanes, Elsa

    2015-03-01

    Neurons communicate via chemical signals called neurotransmitters (NTs). The numerous identified NTs can have very different physiochemical properties (solubility, charge, size etc.), so quantification of the various NT classes traditionally requires several analytical platforms/methodologies. We here report that a diverse range of NTs, e.g. peptides oxytocin and vasopressin, monoamines adrenaline and serotonin, and amino acid GABA, can be simultaneously identified/measured in small samples, using an analytical platform based on liquid chromatography and high-resolution mass spectrometry (LC-MS). The automated platform is cost-efficient as manual sample preparation steps and one-time-use equipment are kept to a minimum. Zwitter-ionic HILIC stationary phases were used for both on-line solid phase extraction (SPE) and liquid chromatography (capillary format, cLC). This approach enabled compounds from all NT classes to elute in small volumes producing sharp and symmetric signals, and allowing precise quantifications of small samples, demonstrated with whole blood (100 microliters per sample). An additional robustness-enhancing feature is automatic filtration/filter back-flushing (AFFL), allowing hundreds of samples to be analyzed without any parts needing replacement. The platform can be installed by simple modification of a conventional LC-MS system.

  12. [Comparison of MPure-12 Automatic Nucleic Acid Purification and Chelex-100 Method].

    PubMed

    Shen, X; Li, M; Wang, Y L; Chen, Y L; Lin, Y; Zhao, Z M; Que, T Z

    2017-04-01

    To explore the forensic application value of MPure-12 automatic nucleic acid purification (MPure-12 Method) for DNA extraction by extracting and typing DNA from bloodstains and various kinds of biological samples with different DNA contents. Nine types of biological samples, such as bloodstains, semen stains, and saliva were collected. DNA were extracted using MPure-12 method and Chelex-100 method, followed by PCR amplification and electrophoresis for obtaining STR-profiles. The samples such as hair root, chutty, butt, muscular tissue, saliva stain, bloodstain and semen stain were typed successfully by MPure-12 method. Partial alleles were lacked in the samples of saliva, and the genotyping of contact swabs was unsatisfactory. Additional, all of the bloodstains (20 μL, 15 μL, 10 μL, 5 μL, 1 μL) showed good typing results using Chelex-100 method. But the loss of alleles occurred in 1 μL blood volume by MPure-12 method. MPure-12 method is suitable for DNA extraction of a certain concentration blood samples.Chelex-100 method may be better for the extraction of trace blood samples.This instrument used in nucleic acid extraction has the advantages of simplicity of operator, rapidity, high extraction efficiency, high rate of reportable STR-profiles and lower man-made pollution. Copyright© by the Editorial Department of Journal of Forensic Medicine

  13. Rotor assembly and method for automatically processing liquids

    DOEpatents

    Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.

    1992-01-01

    A rotor assembly for performing a relatively large number of processing steps upon a sample, such as a whole blood sample, and a diluent, such as water, includes a rotor body for rotation about an axis and including a network of chambers within which various processing steps are performed upon the sample and diluent and passageways through which the sample and diluent are transferred. A transfer mechanism is movable through the rotor body by the influence of a magnetic field generated adjacent the transfer mechanism and movable along the rotor body, and the assembly utilizes centrifugal force, a transfer of momentum and capillary action to perform any of a number of processing steps such as separation, aliquoting, transference, washing, reagent addition and mixing of the sample and diluent within the rotor body. The rotor body is particularly suitable for automatic immunoassay analyses.

  14. Size-based cell sorting with a resistive pulse sensor and an electromagnetic pump in a microfluidic chip.

    PubMed

    Song, Yongxin; Li, Mengqi; Pan, Xinxiang; Wang, Qi; Li, Dongqing

    2015-02-01

    An electrokinetic microfluidic chip is developed to detect and sort target cells by size from human blood samples. Target-cell detection is achieved by a differential resistive pulse sensor (RPS) based on the size difference between the target cell and other cells. Once a target cell is detected, the detected RPS signal will automatically actuate an electromagnetic pump built in a microchannel to push the target cell into a collecting channel. This method was applied to automatically detect and sort A549 cells and T-lymphocytes from a peripheral fingertip blood sample. The viability of A549 cells sorted in the collecting well was verified by Hoechst33342 and propidium iodide staining. The results show that as many as 100 target cells per minute can be sorted out from the sample solution and thus is particularly suitable for sorting very rare target cells, such as circulating tumor cells. The actuation of the electromagnetic valve has no influence on RPS cell detection and the consequent cell-sorting process. The viability of the collected A549 cell is not impacted by the applied electric field when the cell passes the RPS detection area. The device described in this article is simple, automatic, and label-free and has wide applications in size-based rare target cell sorting for medical diagnostics. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Physiological and Pathological Impact of Blood Sampling by Retro-Bulbar Sinus Puncture and Facial Vein Phlebotomy in Laboratory Mice

    PubMed Central

    Holst, Birgitte; Hau, Jann; Rozell, Björn; Abelson, Klas Stig Peter

    2014-01-01

    Retro-bulbar sinus puncture and facial vein phlebotomy are two widely used methods for blood sampling in laboratory mice. However, the animal welfare implications associated with these techniques are currently debated, and the possible physiological and pathological implications of blood sampling using these methods have been sparsely investigated. Therefore, this study was conducted to assess and compare the impacts of blood sampling by retro-bulbar sinus puncture and facial vein phlebotomy. Blood was obtained from either the retro-bulbar sinus or the facial vein from male C57BL/6J mice at two time points, and the samples were analyzed for plasma corticosterone. Body weights were measured at the day of blood sampling and the day after blood sampling, and the food consumption was recorded automatically during the 24 hours post-procedure. At the end of study, cheeks and orbital regions were collected for histopathological analysis to assess the degree of tissue trauma. Mice subjected to facial vein phlebotomy had significantly elevated plasma corticosterone levels at both time points in contrast to mice subjected to retro-bulbar sinus puncture, which did not. Both groups of sampled mice lost weight following blood sampling, but the body weight loss was higher in mice subjected to facial vein phlebotomy. The food consumption was not significantly different between the two groups. At gross necropsy, subcutaneous hematomas were found in both groups and the histopathological analyses revealed extensive tissue trauma after both facial vein phlebotomy and retro-bulbar sinus puncture. This study demonstrates that both blood sampling methods have a considerable impact on the animals' physiological condition, which should be considered whenever blood samples are obtained. PMID:25426941

  16. Automatic retinal blood vessel parameter calculation in spectral domain optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Wehbe, Hassan; Ruggeri, Marco; Jiao, Shuliang; Gregori, Giovanni; Puliafito, Carmen A.

    2007-02-01

    Measurement of retinal blood vessel parameters like the blood blow in the vessels may have significant impact on the study and diagnosis of glaucoma, a leading blinding disease worldwide. Optical coherence tomography (OCT) is a noninvasive imaging technique that can provide not only microscopic structural imaging of the retina but also functional information like the blood flow velocity in the retina. The aim of this study is to automatically extract the parameters of retinal blood vessels like the 3D orientation, the vessel diameters, as well as the corresponding absolute blood flow velocity in the vessel. The parameters were extracted from circular OCT scans around the optic disc. By removing the surface reflection through simple segmentation of the circular OCT scans a blood vessel shadowgram can be generated. The lateral coordinates and the diameter of each blood vessel are extracted from the shadowgram through a series of signal processing. Upon determination of the lateral position and the vessel diameter, the coordinate in the depth direction of each blood vessel is calculated in combination with the Doppler information for the vessel. The extraction of the vessel coordinates and diameter makes it possible to calculate the orientation of the vessel in reference to the direction of the incident sample light, which in turn can be used to calculate the absolute blood flow velocity and the flow rate.

  17. Rotor assembly and method for automatically processing liquids

    DOEpatents

    Burtis, C.A.; Johnson, W.F.; Walker, W.A.

    1992-12-22

    A rotor assembly is described for performing a relatively large number of processing steps upon a sample, such as a whole blood sample, and a diluent, such as water. It includes a rotor body for rotation about an axis and includes a network of chambers within which various processing steps are performed upon the sample and diluent and passageways through which the sample and diluent are transferred. A transfer mechanism is movable through the rotor body by the influence of a magnetic field generated adjacent the transfer mechanism and movable along the rotor body, and the assembly utilizes centrifugal force, a transfer of momentum and capillary action to perform any of a number of processing steps such as separation, aliquoting, transference, washing, reagent addition and mixing of the sample and diluent within the rotor body. The rotor body is particularly suitable for automatic immunoassay analyses. 34 figs.

  18. Evaluation of droplet digital PCR for quantification of residual leucocytes in red blood cell concentrates.

    PubMed

    Doescher, A; Loges, U; Petershofen, E K; Müller, T H

    2017-11-01

    Enumeration of residual white blood cells in leucoreduced blood components is essential part of quality control. Digital PCR has substantially facilitated quantitative PCR and was thus evaluated for measurements of leucocytes. Target for quantification of leucocytes by digital droplet PCR was the blood group gene RHCE. The SPEF1 gene was added as internal control for the entire assay starting with automated DNA extraction. The sensitivity of the method was determined by serial dilutions of standard samples. Quality control samples were analysed within 24 h, 7 days and 6 months after collection. Routine samples from leucodepleted red blood cell concentrates (n = 150) were evaluated in parallel by flow-cytometry (LeucoCount) and by digital PCR. Digital PCR reliably detected at least 0·4 leucocytes per assay. The mean difference between PCR and flow-cytometric results from 150 units was -0·01 (±1·0). DNA samples were stable for up to at least six months. PCR measurement of leucocytes in samples from plasma and platelet concentrates also provided valid results in a pilot study. Droplet digital PCR to enumerate leucocytes offers an alternative for quality control of leucoreduced blood products. Sensitivity, specificity and reproducibility are comparable to flow-cytometry. The option to collect samples over an extended period of time and the automatization introduce attractive features for routine quality control. © 2017 International Society of Blood Transfusion.

  19. Fabrication of subcutaneous veins phantom for vessel visualization system

    NASA Astrophysics Data System (ADS)

    Cheng, Kai; Narita, Kazuyuki; Morita, Yusuke; Nakamachi, Eiji; Honda, Norihiro; Awazu, Kunio

    2013-09-01

    The technique of subcutaneous veins imaging by using NIR (Near Infrared Radiation) is widely used in medical applications, such as the intravenous injection and the blood sampling. In the previous study, an automatic 3D blood vessel search and automatic blood sampling system was newly developed. In order to validate this NIR imaging system, we adopted the subcutaneous vein in the human arm and its artificial phantom, which imitate the human fat and blood vessel. The human skin and subcutaneous vein is characterized as the uncertainty object, which has the individual specificity, non-accurate depth information, non-steady state and hardly to be fixed in the examination apparatus. On the other hand, the conventional phantom was quite distinct from the human's characteristics, such as the non-multilayer structure, disagreement of optical property. In this study, we develop a multilayer phantom, which is quite similar with human skin, for improvement of NIR detection system evaluation. The phantom consists of three layers, such as the epidermis layer, the dermis layer and the subcutaneous fat layer. In subcutaneous fat layer, we built a blood vessel. We use the intralipid to imitate the optical scattering characteristics of human skin, and the hemoglobin and melanin for the optical absorption characteristics. In this study, we did two subjects. First, we decide the fabrication process of the phantom. Second, we compared newly developed phantoms with human skin by using our NIR detecting system, and confirm the availability of these phantoms.

  20. Identification of forensic samples by using an infrared-based automatic DNA sequencer.

    PubMed

    Ricci, Ugo; Sani, Ilaria; Klintschar, Michael; Cerri, Nicoletta; De Ferrari, Francesco; Giovannucci Uzielli, Maria Luisa

    2003-06-01

    We have recently introduced a new protocol for analyzing all core loci of the Federal Bureau of Investigation's (FBI) Combined DNA Index System (CODIS) with an infrared (IR) automatic DNA sequencer (LI-COR 4200). The amplicons were labeled with forward oligonucleotide primers, covalently linked to a new infrared fluorescent molecule (IRDye 800). The alleles were displayed as familiar autoradiogram-like images with real-time detection. This protocol was employed for paternity testing, population studies, and identification of degraded forensic samples. We extensively analyzed some simulated forensic samples and mixed stains (blood, semen, saliva, bones, and fixed archival embedded tissues), comparing the results with donor samples. Sensitivity studies were also performed for the four multiplex systems. Our results show the efficiency, reliability, and accuracy of the IR system for the analysis of forensic samples. We also compared the efficiency of the multiplex protocol with ultraviolet (UV) technology. Paternity tests, undegraded DNA samples, and real forensic samples were analyzed with this approach based on IR technology and with UV-based automatic sequencers in combination with commercially-available kits. The comparability of the results with the widespread UV methods suggests that it is possible to exchange data between laboratories using the same core group of markers but different primer sets and detection methods.

  1. [Establishment of Automation System for Detection of Alcohol in Blood].

    PubMed

    Tian, L L; Shen, Lei; Xue, J F; Liu, M M; Liang, L J

    2017-02-01

    To establish an automation system for detection of alcohol content in blood. The determination was performed by automated workstation of extraction-headspace gas chromatography (HS-GC). The blood collection with negative pressure, sealing time of headspace bottle and sample needle were checked and optimized in the abstraction of automation system. The automatic sampling was compared with the manual sampling. The quantitative data obtained by the automated workstation of extraction-HS-GC for alcohol was stable. The relative differences of two parallel samples were less than 5%. The automated extraction was superior to the manual extraction. A good linear relationship was obtained at the alcohol concentration range of 0.1-3.0 mg/mL ( r ≥0.999) with good repeatability. The method is simple and quick, with more standard experiment process and accurate experimental data. It eliminates the error from the experimenter and has good repeatability, which can be applied to the qualitative and quantitative detections of alcohol in blood. Copyright© by the Editorial Department of Journal of Forensic Medicine

  2. Experiment on aggregation of red cells under microgravity on STS 51-C

    NASA Astrophysics Data System (ADS)

    Dintenfass, L.; Osman, P.; Maguire, B.; Jedrzejczyk, H.

    Kinetics and morphology of aggregation of red cells were studied using automatic slit-capillary photo-viscometers, one situated on the middeck of the space shuttle `Discovery', and the other in the ground laboratory at KSC. Experiments were run simultaneously, blood samples being adjusted to haematocrit of 0.30 using native plasma, at temp. of 25°C, and anticoagulated by EDTA. Donors included patients with myocardial infarction, insulin-dependent diabetes, hyperlipidaemia and hypertension. Macro and microphotographs were obtained during flow and statis. There was a striking difference in the morphology of aggregates formed in space and on the ground. Aggregates formed under zero gravity showed rouleaux formation, while the same blood samples showed severe clumping on the ground, in all patients blood. Normal blood showed rouleaux on the ground, but a random swarm-like pattern in space. The shape of the red cells remained normal under zero gravity.

  3. A critical evaluation of automated blood gas measurements in comparative respiratory physiology.

    PubMed

    Malte, Christian Lind; Jakobsen, Sashia Lindhøj; Wang, Tobias

    2014-12-01

    Precise measurements of blood gases and pH are of pivotal importance to respiratory physiology. However, the traditional electrodes that could be calibrated and maintained at the same temperature as the experimental animal are increasingly being replaced by new automated blood gas analyzers. These are typically designed for clinical use and automatically heat the blood sample to 37°C for measurements. While most blood gas analyzers allow for temperature corrections of the measurements, the underlying algorithms are based on temperature-effects for human blood, and any discrepancies in the temperature dependency between the blood sample from a given species and human samples will bias measurements. In this study we review the effects of temperature on blood gases and pH and evaluate the performance of an automated blood gas analyzer (GEM Premier 3500). Whole blood obtained from pythons and freshwater turtles was equilibrated in rotating Eschweiler tonometers to a variety of known P(O2)'s and P(CO2)'s in gas mixtures prepared by Wösthoff gas mixing pumps and blood samples were measured immediately on the GEM Premier 3500. The pH measurements were compared to measurements using a Radiometer BMS glass capillary pH electrode kept and calibrated at the experimental temperature. We show that while the blood gas analyzer provides reliable temperature-corrections for P(CO2) and pH, P(O2) measurements were substantially biased. This was in agreement with the theoretical considerations and emphasizes the need for critical calibrations/corrections when using automated blood gas analyzers. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Forensic identification of blood in the presence of contaminations using Raman microspectroscopy coupled with advanced statistics: effect of sand, dust, and soil.

    PubMed

    Sikirzhytskaya, Aliaksandra; Sikirzhytski, Vitali; McLaughlin, Gregory; Lednev, Igor K

    2013-09-01

    Body fluid traces recovered at crime scenes are among the most common and important types of forensic evidence. However, the ability to characterize a biological stain at a crime scene nondestructively has not yet been demonstrated. Here, we expand the Raman spectroscopic approach for the identification of dry traces of pure body fluids to address the problem of heterogeneous contamination, which can impair the performance of conventional methods. The concept of multidimensional Raman signatures was utilized for the identification of blood in dry traces contaminated with sand, dust, and soil. Multiple Raman spectra were acquired from the samples via automatic scanning, and the contribution of blood was evaluated through the fitting quality using spectroscopic signature components. The spatial mapping technique allowed for detection of "hot spots" dominated by blood contribution. The proposed method has great potential for blood identification in highly contaminated samples. © 2013 American Academy of Forensic Sciences.

  5. [Optimization of isolation of the concentrate of stem cells from the umbilical blood].

    PubMed

    Tiumina, O V; Savchenko, V G; Gusarova, G I; Pavlov, V V; Zharkov, M N; Volchkov, S E; Rossiev, V A; Gridasov, G N

    2005-01-01

    To study correlations between body mass and height of the newborn, Apgar scale estimates, gestation time, volume of the obtained umbilical blood (UB), number of nucleated cells (NC); to compare manual and automatic modes of UB processing. 330 procurements of UB were made, 230 (69.7%) samples were frozen. Comparison of 2 techniques of UB processing was made in 73 cases of double centrifugation with hydroxyethylstarch (HES) and 47 cases of using separator Sepax (Biosafe, Switzerland). Blood cell count before and after UB processing and number of CD34+ cells were estimated. A correlation analysis was made of dependence of the volume of 102 samples of UB on the weight (r = 0.268, p < 0.01) and height of the fetus (r = 0.203, p < 0.05), estimation by Apgar scale (r = -0.092, p < 0.1) and gestation term (r = -0.003, p > 0.1); analysis of the number of NC dependence on the volume of UB (r = 0.102 p < 0.1), mass (r = 0.073 p > 0.1) and fetus height (r = 0.121 p > 0.1), gestation time (r = 0.159 p > 0.1), Apgar scale assessment (r = -0.174 p > 0.1). In manual UB management NC yield made up 71.9 +/- 6.7%, in automatic--81 +/- 8.0% (p < 0.05). Percent of erythrocytes removal was 73 +/- 5.7% and 80.5 +/- 6.1% (p < 0.05), respectively. A weak correlation was found between UB volume, mass and height of the fetus. The number of NC in UB depends on none of the parameters. Automatic processing of UB provides a greater release of NC and better elimination of erythrocytes in minimal risk of contamination.

  6. A system for automatic analysis of blood pressure data for digital computer entry

    NASA Technical Reports Server (NTRS)

    Miller, R. L.

    1972-01-01

    Operation of automatic blood pressure data system is described. Analog blood pressure signal is analyzed by three separate circuits, systolic, diastolic, and cycle defect. Digital computer output is displayed on teletype paper tape punch and video screen. Illustration of system is included.

  7. A new machine classification method applied to human peripheral blood leukocytes

    NASA Technical Reports Server (NTRS)

    Rorvig, Mark E.; Fitzpatrick, Steven J.; Vitthal, Sanjay; Ladoulis, Charles T.

    1994-01-01

    Human beings judge images by complex mental processes, whereas computing machines extract features. By reducing scaled human judgments and machine extracted features to a common metric space and fitting them by regression, the judgments of human experts rendered on a sample of images may be imposed on an image population to provide automatic classification.

  8. Automatic tracking of labeled red blood cells in microchannels.

    PubMed

    Pinho, Diana; Lima, Rui; Pereira, Ana I; Gayubo, Fernando

    2013-09-01

    The current study proposes an automatic method for the segmentation and tracking of red blood cells flowing through a 100- μm glass capillary. The original images were obtained by means of a confocal system and then processed in MATLAB using the Image Processing Toolbox. The measurements obtained with the proposed automatic method were compared with the results determined by a manual tracking method. The comparison was performed by using both linear regressions and Bland-Altman analysis. The results have shown a good agreement between the two methods. Therefore, the proposed automatic method is a powerful way to provide rapid and accurate measurements for in vitro blood experiments in microchannels. Copyright © 2012 John Wiley & Sons, Ltd.

  9. [Blood stream infection and blood culture--"progress" and "blind" in blood culture testing].

    PubMed

    Kobayashi, Intetsu

    2005-04-01

    We have investigated various types of blood culture bottles which are mainly used at present and posed problems present in the blood culture bottles. First, there are differences between resin and ecosorb in the ability to adsorb and inactivate antibiotics in the blood. Second, the delay in placing the bottle (into which blood was inoculated) to the automatic instrument (delay in the start of incubation) greatly affects the automatic detection by BACTEC system and shows false negatives. Third, when the same blood is incubated in plural bottles (aerobic and anaerobic bottles), the differences among the detected organisms in the number are comparatively high, i.e., about 40%. In addition, there are differences among the organisms in the number of days required for the detection of the organisms. In this case, the detected organisms are clearly different in many cases. The technology of blood culture has been progressed remarkably. However, the efficiency of utilization of automatic instruments for diagnosis of infection depends greatly on the ability of laboratory technicians.

  10. Simultaneous Automatic Electrochemical Detection of Zinc, Cadmium, Copper and Lead Ions in Environmental Samples Using a Thin-Film Mercury Electrode and an Artificial Neural Network

    PubMed Central

    Kudr, Jiri; Nguyen, Hoai Viet; Gumulec, Jaromir; Nejdl, Lukas; Blazkova, Iva; Ruttkay-Nedecky, Branislav; Hynek, David; Kynicky, Jindrich; Adam, Vojtech; Kizek, Rene

    2015-01-01

    In this study a device for automatic electrochemical analysis was designed. A three electrodes detection system was attached to a positioning device, which enabled us to move the electrode system from one well to another of a microtitre plate. Disposable carbon tip electrodes were used for Cd(II), Cu(II) and Pb(II) ion quantification, while Zn(II) did not give signal in this electrode configuration. In order to detect all mentioned heavy metals simultaneously, thin-film mercury electrodes (TFME) were fabricated by electrodeposition of mercury on the surface of carbon tips. In comparison with bare electrodes the TMFEs had lower detection limits and better sensitivity. In addition to pure aqueous heavy metal solutions, the assay was also performed on mineralized rock samples, artificial blood plasma samples and samples of chicken embryo organs treated with cadmium. An artificial neural network was created to evaluate the concentrations of the mentioned heavy metals correctly in mixture samples and an excellent fit was observed (R2 = 0.9933). PMID:25558996

  11. Image-based red cell counting for wild animals blood.

    PubMed

    Mauricio, Claudio R M; Schneider, Fabio K; Dos Santos, Leonilda Correia

    2010-01-01

    An image-based red blood cell (RBC) automatic counting system is presented for wild animals blood analysis. Images with 2048×1536-pixel resolution acquired on an optical microscope using Neubauer chambers are used to evaluate RBC counting for three animal species (Leopardus pardalis, Cebus apella and Nasua nasua) and the error found using the proposed method is similar to that obtained for inter observer visual counting method, i.e., around 10%. Smaller errors (e.g., 3%) can be obtained in regions with less grid artifacts. These promising results allow the use of the proposed method either as a complete automatic counting tool in laboratories for wild animal's blood analysis or as a first counting stage in a semi-automatic counting tool.

  12. Three Dimensional Imaging of Paraffin Embedded Human Lung Tissue Samples by Micro-Computed Tomography

    PubMed Central

    Scott, Anna E.; Vasilescu, Dragos M.; Seal, Katherine A. D.; Keyes, Samuel D.; Mavrogordato, Mark N.; Hogg, James C.; Sinclair, Ian; Warner, Jane A.; Hackett, Tillie-Louise; Lackie, Peter M.

    2015-01-01

    Background Understanding the three-dimensional (3-D) micro-architecture of lung tissue can provide insights into the pathology of lung disease. Micro computed tomography (µCT) has previously been used to elucidate lung 3D histology and morphometry in fixed samples that have been stained with contrast agents or air inflated and dried. However, non-destructive microstructural 3D imaging of formalin-fixed paraffin embedded (FFPE) tissues would facilitate retrospective analysis of extensive tissue archives of lung FFPE lung samples with linked clinical data. Methods FFPE human lung tissue samples (n = 4) were scanned using a Nikon metrology µCT scanner. Semi-automatic techniques were used to segment the 3D structure of airways and blood vessels. Airspace size (mean linear intercept, Lm) was measured on µCT images and on matched histological sections from the same FFPE samples imaged by light microscopy to validate µCT imaging. Results The µCT imaging protocol provided contrast between tissue and paraffin in FFPE samples (15mm x 7mm). Resolution (voxel size 6.7 µm) in the reconstructed images was sufficient for semi-automatic image segmentation of airways and blood vessels as well as quantitative airspace analysis. The scans were also used to scout for regions of interest, enabling time-efficient preparation of conventional histological sections. The Lm measurements from µCT images were not significantly different to those from matched histological sections. Conclusion We demonstrated how non-destructive imaging of routinely prepared FFPE samples by laboratory µCT can be used to visualize and assess the 3D morphology of the lung including by morphometric analysis. PMID:26030902

  13. Diffraction phase microscopy realized with an automatic digital pinhole

    NASA Astrophysics Data System (ADS)

    Zheng, Cheng; Zhou, Renjie; Kuang, Cuifang; Zhao, Guangyuan; Zhang, Zhimin; Liu, Xu

    2017-12-01

    We report a novel approach to diffraction phase microscopy (DPM) with automatic pinhole alignment. The pinhole, which serves as a spatial low-pass filter to generate a uniform reference beam, is made out of a liquid crystal display (LCD) device that allows for electrical control. We have made DPM more accessible to users, while maintaining high phase measurement sensitivity and accuracy, through exploring low cost optical components and replacing the tedious pinhole alignment process with an automatic pinhole optical alignment procedure. Due to its flexibility in modifying the size and shape, this LCD device serves as a universal filter, requiring no future replacement. Moreover, a graphic user interface for real-time phase imaging has been also developed by using a USB CMOS camera. Experimental results of height maps of beads sample and live red blood cells (RBCs) dynamics are also presented, making this system ready for broad adaption to biological imaging and material metrology.

  14. Adaptive and automatic red blood cell counting method based on microscopic hyperspectral imaging technology

    NASA Astrophysics Data System (ADS)

    Liu, Xi; Zhou, Mei; Qiu, Song; Sun, Li; Liu, Hongying; Li, Qingli; Wang, Yiting

    2017-12-01

    Red blood cell counting, as a routine examination, plays an important role in medical diagnoses. Although automated hematology analyzers are widely used, manual microscopic examination by a hematologist or pathologist is still unavoidable, which is time-consuming and error-prone. This paper proposes a full-automatic red blood cell counting method which is based on microscopic hyperspectral imaging of blood smears and combines spatial and spectral information to achieve high precision. The acquired hyperspectral image data of the blood smear in the visible and near-infrared spectral range are firstly preprocessed, and then a quadratic blind linear unmixing algorithm is used to get endmember abundance images. Based on mathematical morphological operation and an adaptive Otsu’s method, a binaryzation process is performed on the abundance images. Finally, the connected component labeling algorithm with magnification-based parameter setting is applied to automatically select the binary images of red blood cell cytoplasm. Experimental results show that the proposed method can perform well and has potential for clinical applications.

  15. Raman spectroscopy coupled with advanced statistics for differentiating menstrual and peripheral blood.

    PubMed

    Sikirzhytskaya, Aliaksandra; Sikirzhytski, Vitali; Lednev, Igor K

    2014-01-01

    Body fluids are a common and important type of forensic evidence. In particular, the identification of menstrual blood stains is often a key step during the investigation of rape cases. Here, we report on the application of near-infrared Raman microspectroscopy for differentiating menstrual blood from peripheral blood. We observed that the menstrual and peripheral blood samples have similar but distinct Raman spectra. Advanced statistical analysis of the multiple Raman spectra that were automatically (Raman mapping) acquired from the 40 dried blood stains (20 donors for each group) allowed us to build classification model with maximum (100%) sensitivity and specificity. We also demonstrated that despite certain common constituents, menstrual blood can be readily distinguished from vaginal fluid. All of the classification models were verified using cross-validation methods. The proposed method overcomes the problems associated with currently used biochemical methods, which are destructive, time consuming and expensive. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. An automatic bolus injector for use in radiotracer studies of blood flow: design and evaluation.

    PubMed

    Snyder, R E; Overton, T R; Boisvert, D P; Petruk, K C

    1976-12-01

    An electromechanical device is described which automatically injects the radiotracer bolus used in the measurement of cerebral blood flow. It consists of two electronically controlled, solenoid operated syringes, one containing the radiotracer solution and the other heparinized saline. Results are presented which show that use of the automatic bolus injector in place of hand injection leads to an improvement in the precision of measured flow values. Additional advantages of the device are discussed.

  17. A method of automatic control procedures cardiopulmonary resuscitation

    NASA Astrophysics Data System (ADS)

    Bureev, A. Sh.; Zhdanov, D. S.; Kiseleva, E. Yu.; Kutsov, M. S.; Trifonov, A. Yu.

    2015-11-01

    The study is to present the results of works on creation of methods of automatic control procedures of cardiopulmonary resuscitation (CPR). A method of automatic control procedure of CPR by evaluating the acoustic data of the dynamics of blood flow in the bifurcation of carotid arteries and the dynamics of air flow in a trachea according to the current guidelines for CPR is presented. Evaluation of the patient is carried out by analyzing the respiratory noise and blood flow in the interspaces between the chest compressions and artificial pulmonary ventilation. The device operation algorithm of automatic control procedures of CPR and its block diagram has been developed.

  18. Continuous representation of tumor microvessel density and detection of angiogenic hotspots in histological whole-slide images.

    PubMed

    Kather, Jakob Nikolas; Marx, Alexander; Reyes-Aldasoro, Constantino Carlos; Schad, Lothar R; Zöllner, Frank Gerrit; Weis, Cleo-Aron

    2015-08-07

    Blood vessels in solid tumors are not randomly distributed, but are clustered in angiogenic hotspots. Tumor microvessel density (MVD) within these hotspots correlates with patient survival and is widely used both in diagnostic routine and in clinical trials. Still, these hotspots are usually subjectively defined. There is no unbiased, continuous and explicit representation of tumor vessel distribution in histological whole slide images. This shortcoming distorts angiogenesis measurements and may account for ambiguous results in the literature. In the present study, we describe and evaluate a new method that eliminates this bias and makes angiogenesis quantification more objective and more efficient. Our approach involves automatic slide scanning, automatic image analysis and spatial statistical analysis. By comparing a continuous MVD function of the actual sample to random point patterns, we introduce an objective criterion for hotspot detection: An angiogenic hotspot is defined as a clustering of blood vessels that is very unlikely to occur randomly. We evaluate the proposed method in N=11 images of human colorectal carcinoma samples and compare the results to a blinded human observer. For the first time, we demonstrate the existence of statistically significant hotspots in tumor images and provide a tool to accurately detect these hotspots.

  19. Development of a cerebral circulation model for the automatic control of brain physiology.

    PubMed

    Utsuki, T

    2015-01-01

    In various clinical guidelines of brain injury, intracranial pressure (ICP), cerebral blood flow (CBF) and brain temperature (BT) are essential targets for precise management for brain resuscitation. In addition, the integrated automatic control of BT, ICP, and CBF is required for improving therapeutic effects and reducing medical costs and staff burden. Thus, a new model of cerebral circulation was developed in this study for integrative automatic control. With this model, the CBF and cerebral perfusion pressure of a normal adult male were regionally calculated according to cerebrovascular structure, blood viscosity, blood distribution, CBF autoregulation, and ICP. The analysis results were consistent with physiological knowledge already obtained with conventional studies. Therefore, the developed model is potentially available for the integrative control of the physiological state of the brain as a reference model of an automatic control system, or as a controlled object in various control simulations.

  20. Automatic analysis of microscopic images of red blood cell aggregates

    NASA Astrophysics Data System (ADS)

    Menichini, Pablo A.; Larese, Mónica G.; Riquelme, Bibiana D.

    2015-06-01

    Red blood cell aggregation is one of the most important factors in blood viscosity at stasis or at very low rates of flow. The basic structure of aggregates is a linear array of cell commonly termed as rouleaux. Enhanced or abnormal aggregation is seen in clinical conditions, such as diabetes and hypertension, producing alterations in the microcirculation, some of which can be analyzed through the characterization of aggregated cells. Frequently, image processing and analysis for the characterization of RBC aggregation were done manually or semi-automatically using interactive tools. We propose a system that processes images of RBC aggregation and automatically obtains the characterization and quantification of the different types of RBC aggregates. Present technique could be interesting to perform the adaptation as a routine used in hemorheological and Clinical Biochemistry Laboratories because this automatic method is rapid, efficient and economical, and at the same time independent of the user performing the analysis (repeatability of the analysis).

  1. Automated measurement of retinal vascular tortuosity.

    PubMed Central

    Hart, W. E.; Goldbaum, M.; Côté, B.; Kube, P.; Nelson, M. R.

    1997-01-01

    Automatic measurement of blood vessel tortuosity is a useful capability for automatic ophthalmological diagnostic tools. We describe a suite of automated tortuosity measures for blood vessel segments extracted from RGB retinal images. The tortuosity measures were evaluated in two classification tasks: (1) classifying the tortuosity of blood vessel segments and (2) classifying the tortuosity of blood vessel networks. These tortuosity measures were able to achieve a classification rate of 91% for the first problem and 95% on the second problem, which confirms that they capture much of the ophthalmologists' notion of tortuosity. Images Figure 1 PMID:9357668

  2. Direct detection of cancer biomarkers in blood using a "place n play" modular polydimethylsiloxane pump.

    PubMed

    Zhang, Honglian; Li, Gang; Liao, Lingying; Mao, Hongju; Jin, Qinghui; Zhao, Jianlong

    2013-01-01

    Cancer biomarkers have significant potential as reliable tools for the early detection of the disease and for monitoring its recurrence. However, most current methods for biomarker detection have technical difficulties (such as sample preparation and specific detector requirements) which limit their application in point of care diagnostics. We developed an extremely simple, power-free microfluidic system for direct detection of cancer biomarkers in microliter volumes of whole blood. CEA and CYFRA21-1 were chosen as model cancer biomarkers. The system automatically extracted blood plasma from less than 3 μl of whole blood and performed a multiplex sample-to-answer assay (nano-ELISA (enzyme-linked immunosorbent assay) technique) without the use of external power or extra components. By taking advantage of the nano-ELISA technique, this microfluidic system detected CEA at a concentration of 50 pg/ml and CYFRA21-1 at a concentration of 60 pg/ml within 60 min. The combination of PnP polydimethylsiloxane (PDMS) pump and nano-ELISA technique in a single microchip system shows great promise for the detection of cancer biomarkers in a drop of blood.

  3. Automated renal histopathology: digital extraction and quantification of renal pathology

    NASA Astrophysics Data System (ADS)

    Sarder, Pinaki; Ginley, Brandon; Tomaszewski, John E.

    2016-03-01

    The branch of pathology concerned with excess blood serum proteins being excreted in the urine pays particular attention to the glomerulus, a small intertwined bunch of capillaries located at the beginning of the nephron. Normal glomeruli allow moderate amount of blood proteins to be filtered; proteinuric glomeruli allow large amount of blood proteins to be filtered. Diagnosis of proteinuric diseases requires time intensive manual examination of the structural compartments of the glomerulus from renal biopsies. Pathological examination includes cellularity of individual compartments, Bowman's and luminal space segmentation, cellular morphology, glomerular volume, capillary morphology, and more. Long examination times may lead to increased diagnosis time and/or lead to reduced precision of the diagnostic process. Automatic quantification holds strong potential to reduce renal diagnostic time. We have developed a computational pipeline capable of automatically segmenting relevant features from renal biopsies. Our method first segments glomerular compartments from renal biopsies by isolating regions with high nuclear density. Gabor texture segmentation is used to accurately define glomerular boundaries. Bowman's and luminal spaces are segmented using morphological operators. Nuclei structures are segmented using color deconvolution, morphological processing, and bottleneck detection. Average computation time of feature extraction for a typical biopsy, comprising of ~12 glomeruli, is ˜69 s using an Intel(R) Core(TM) i7-4790 CPU, and is ~65X faster than manual processing. Using images from rat renal tissue samples, automatic glomerular structural feature estimation was reproducibly demonstrated for 15 biopsy images, which contained 148 individual glomeruli images. The proposed method holds immense potential to enhance information available while making clinical diagnoses.

  4. [Development of an automatic pneumatic tourniquet system that determines pressures in synchrony with systolic blood pressure].

    PubMed

    Liu, Hongyun; Li, Kaiyuan; Zhang, Zhengbo; Guo, Junyan; Wang, Weidong

    2012-11-01

    The correlation coefficients between arterial occlusion pressure and systolic blood pressure, diastolic blood pressure, limb circumference, body mass etc were obtained through healthy volunteer experiments, in which tourniquet were applied on upper/lower extremities. The prediction equations were derived from the data of experiments by multiple regression analysis. Based on the microprocessor C8051F340, a new pneumatic tourniquet system that can determine tourniquet pressure in synchrony with systolic blood pressure was developed and verified the function and stability of designed system. Results showed that the pneumatic tourniquet which automatically adjusts occlusion pressure in accordance with systolic blood pressure could stop the flow of blood to get a bloodless field.

  5. [The actual possibilities of robotic microscopy in analysis automation and laboratory telemedicine].

    PubMed

    Medovyĭ, V S; Piatnitskiĭ, A M; Sokolinskiĭ, B Z; Balugian, R Sh

    2012-10-01

    The article discusses the possibilities of automation microscopy complexes manufactured by Cellavision and MEKOS to perform the medical analyses of blood films and other biomaterials. The joint work of the complex and physician in the regimen of automatic load stages, screening, sampling and sorting on types with simple morphology, visual sorting of sub-sample with complex morphology provides significant increase of method sensitivity, load decrease and enhancement of physician work conditions. The information technologies, the virtual slides and laboratory telemedicine included permit to develop the representative samples of rare types and pathologies to promote automation methods and medical research targets.

  6. Use of kurtosis for locating deep blood vessels in raw speckle imaging using a homogeneity representation.

    PubMed

    Peregrina-Barreto, Hayde; Perez-Corona, Elizabeth; Rangel-Magdaleno, Jose; Ramos-Garcia, Ruben; Chiu, Roger; Ramirez-San-Juan, Julio C

    2017-06-01

    Visualization of deep blood vessels in speckle images is an important task as it is used to analyze the dynamics of the blood flow and the health status of biological tissue. Laser speckle imaging is a wide-field optical technique to measure relative blood flow speed based on the local speckle contrast analysis. However, it has been reported that this technique is limited to certain deep blood vessels (about ? = 300 ?? ? m ) because of the high scattering of the sample; beyond this depth, the quality of the vessel’s image decreases. The use of a representation based on homogeneity values, computed from the co-occurrence matrix, is proposed as it provides an improved vessel definition and its corresponding diameter. Moreover, a methodology is proposed for automatic blood vessel location based on the kurtosis analysis. Results were obtained from the different skin phantoms, showing that it is possible to identify the vessel region for different morphologies, even up to 900 ?? ? m in depth.

  7. Field performance of a low-cost and fully-automated blood counting system operated by trained and untrained users (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Xie, Dengling; Xie, Yanjun; Liu, Peng; Tong, Lieshu; Chu, Kaiqin; Smith, Zachary J.

    2017-02-01

    Current flow-based blood counting devices require expensive and centralized medical infrastructure and are not appropriate for field use. In this paper we report a method to count red blood cells, white blood cells as well as platelets through a low-cost and fully-automated blood counting system. The approach consists of using a compact, custom-built microscope with large field-of-view to record bright-field and fluorescence images of samples that are diluted with a single, stable reagent mixture and counted using automatic algorithms. Sample collection is performed manually using a spring loaded lancet, and volume-metering capillary tubes. The capillaries are then dropped into a tube of pre-measured reagents and gently shaken for 10-30 seconds. The sample is loaded into a measurement chamber and placed on a custom 3D printed platform. Sample translation and focusing is fully automated, and a user has only to press a button for the measurement and analysis to commence. Cost of the system is minimized through the use of custom-designed motorized components. We performed a series of comparative experiments by trained and untrained users on blood from adults and children. We compare the performance of our system, as operated by trained and untrained users, to the clinical gold standard using a Bland-Altman analysis, demonstrating good agreement of our system to the clinical standard. The system's low cost, complete automation, and good field performance indicate that it can be successfully translated for use in low-resource settings where central hematology laboratories are not accessible.

  8. [Advances in automatic detection technology for images of thin blood film of malaria parasite].

    PubMed

    Juan-Sheng, Zhang; Di-Qiang, Zhang; Wei, Wang; Xiao-Guang, Wei; Zeng-Guo, Wang

    2017-05-05

    This paper reviews the computer vision and image analysis studies aiming at automated diagnosis or screening of malaria in microscope images of thin blood film smears. On the basis of introducing the background and significance of automatic detection technology, the existing detection technologies are summarized and divided into several steps, including image acquisition, pre-processing, morphological analysis, segmentation, count, and pattern classification components. Then, the principles and implementation methods of each step are given in detail. In addition, the promotion and application in automatic detection technology of thick blood film smears are put forwarded as questions worthy of study, and a perspective of the future work for realization of automated microscopy diagnosis of malaria is provided.

  9. Histogram analysis for smartphone-based rapid hematocrit determination

    PubMed Central

    Jalal, Uddin M.; Kim, Sang C.; Shim, Joon S.

    2017-01-01

    A novel and rapid analysis technique using histogram has been proposed for the colorimetric quantification of blood hematocrits. A smartphone-based “Histogram” app for the detection of hematocrits has been developed integrating the smartphone embedded camera with a microfluidic chip via a custom-made optical platform. The developed histogram analysis shows its effectiveness in the automatic detection of sample channel including auto-calibration and can analyze the single-channel as well as multi-channel images. Furthermore, the analyzing method is advantageous to the quantification of blood-hematocrit both in the equal and varying optical conditions. The rapid determination of blood hematocrits carries enormous information regarding physiological disorders, and the use of such reproducible, cost-effective, and standard techniques may effectively help with the diagnosis and prevention of a number of human diseases. PMID:28717569

  10. Performance testing of a semi-automatic card punch system, using direct STR profiling of DNA from blood samples on FTA™ cards.

    PubMed

    Ogden, Samantha J; Horton, Jeffrey K; Stubbs, Simon L; Tatnell, Peter J

    2015-01-01

    The 1.2 mm Electric Coring Tool (e-Core™) was developed to increase the throughput of FTA(™) sample collection cards used during forensic workflows and is similar to a 1.2 mm Harris manual micro-punch for sampling dried blood spots. Direct short tandem repeat (STR) DNA profiling was used to compare samples taken by the e-Core tool with those taken by the manual micro-punch. The performance of the e-Core device was evaluated using a commercially available PowerPlex™ 18D STR System. In addition, an analysis was performed that investigated the potential carryover of DNA via the e-Core punch from one FTA disc to another. This contamination study was carried out using Applied Biosystems AmpflSTR™ Identifiler™ Direct PCR Amplification kits. The e-Core instrument does not contaminate FTA discs when a cleaning punch is used following excision of discs containing samples and generates STR profiles that are comparable to those generated by the manual micro-punch. © 2014 American Academy of Forensic Sciences.

  11. Correlation of salivary glucose level with blood glucose level in diabetes mellitus.

    PubMed

    Gupta, Shreya; Nayak, Meghanand T; Sunitha, J D; Dawar, Geetanshu; Sinha, Nidhi; Rallan, Neelakshi Singh

    2017-01-01

    Saliva is a unique fluid, which is important for normal functioning of the oral cavity. Diabetes mellitus (DM) is a disease of absolute or relative insulin deficiency characterized by insufficient secretion of insulin by pancreatic beta-cells. The diagnosis of diabetes through blood is difficult in children, older adults, debilitated and chronically ill patients, so diagnosis by analysis of saliva can be potentially valuable as collection of saliva is noninvasive, easier and technically insensitive, unlike blood. The aim of the study was to correlate blood glucose level (BGL) and salivary glucose level (SGL) in DM patients. A cross-sectional study was conducted in 120 patients, who were categorized as 40 controlled diabetics, 40 uncontrolled diabetics and 40 healthy, age- and sex-matched individuals constituted the controls. The blood and unstimulated saliva samples were collected from the patients at the different intervals for fasting, random and postprandial levels. These samples were then subjected for analysis of glucose in blood and saliva using glucose oxidase/peroxidase reagent in HITACHI 902 (R) Automatic analyzer, and the results were recorded. The mean SGLs were higher in uncontrolled and controlled diabetic groups than in nondiabetic group. A highly statistically significant correlation was found between fasting saliva glucose and fasting blood glucose in all the groups. With increase in BGL, increase in SGL was observed in patients with diabetes suggesting that SGL can be used for monitoring glycemic level in DM.

  12. Automatic tracking of red blood cells in micro channels using OpenCV

    NASA Astrophysics Data System (ADS)

    Rodrigues, Vânia; Rodrigues, Pedro J.; Pereira, Ana I.; Lima, Rui

    2013-10-01

    The present study aims to developan automatic method able to track red blood cells (RBCs) trajectories flowing through a microchannel using the Open Source Computer Vision (OpenCV). The developed method is based on optical flux calculation assisted by the maximization of the template-matching product. The experimental results show a good functional performance of this method.

  13. A dye-assisted paper-based point-of-care assay for fast and reliable blood grouping.

    PubMed

    Zhang, Hong; Qiu, Xiaopei; Zou, Yurui; Ye, Yanyao; Qi, Chao; Zou, Lingyun; Yang, Xiang; Yang, Ke; Zhu, Yuanfeng; Yang, Yongjun; Zhou, Yang; Luo, Yang

    2017-03-15

    Fast and simultaneous forward and reverse blood grouping has long remained elusive. Forward blood grouping detects antigens on red blood cells, whereas reverse grouping identifies specific antibodies present in plasma. We developed a paper-based assay using immobilized antibodies and bromocresol green dye for rapid and reliable blood grouping, where dye-assisted color changes corresponding to distinct blood components provide a visual readout. ABO antigens and five major Rhesus antigens could be detected within 30 s, and simultaneous forward and reverse ABO blood grouping using small volumes (100 μl) of whole blood was achieved within 2 min through on-chip plasma separation without centrifugation. A machine-learning method was developed to classify the spectral plots corresponding to dye-based color changes, which enabled reproducible automatic grouping. Using optimized operating parameters, the dye-assisted paper assay exhibited comparable accuracy and reproducibility to the classical gel-card assays in grouping 3550 human blood samples. When translated to the assembly line and low-cost manufacturing, the proposed approach may be developed into a cost-effective and robust universal blood-grouping platform. Copyright © 2017, American Association for the Advancement of Science.

  14. Circadian pattern of blood pressure in normal pregnancy and preeclampsia.

    PubMed

    Gupta, Hem Prabha; Singh, R K; Singh, Urmila; Mehrotra, Seema; Verma, N S; Baranwal, Neelam

    2011-08-01

    AIMS #ENTITYSTARTX00026; To find out the circadian pattern of blood pressure in normotensive pregnant women and in women with preeclampsia. A cross-sectional prospective observational case control study. Blood pressure was sampled in thirty-five normotensive pregnant women (control) and thirty five preeclamptic women (study group) by using non-invasive automatic ambulatory blood pressure monitoring machine for 72 h. Blood pressure (BP) was not constant over 24 h period and it oscillated from time to time in control group. BP was maximum during early part of afternoon. However, in preeclampsia besides quantitative increase in BP, circadian BP oscillations were less pronounced and in around 50% subjects BP was maximum during evening and night hours. Both systolic and diastolic BP showed definite reproducible circadian pattern in both preeclamptic and normotensive pregnant women. This pattern both quantitatively and qualitatively was different in preeclamptic women. Standardized 24 h BP monitoring allows quantitative and qualitative evaluation of hypertensive status and is important for timing and dosing of antihypertensive medications.

  15. Relationship between depression and glycemic control among patients with type 2 diabetes in Medan

    NASA Astrophysics Data System (ADS)

    Amelia, R.; Yunanda, Y.

    2018-03-01

    Depression is a mental problem whichifnot handled properly will cause uncontrolled diabetes that affects the quality of life and increase the risk of complications. This study aimed to determine the relationship between depressionwith glycemic control among patients with type 2 Diabetes in Amplas Primary Health Care (PHC) Medan. The study design was a cross-sectional analytic approach. The study population was patients with Type 2 diabetes that is in the region Amplas PHC with a sample of 100 people with consecutive sampling method. We collected data by interviewing and blood analysis. Adapted CES-D questionnaire assessed the depression status. AFull Automatic Spectrophotometer Colorimeter method measured the Blood Sugar Level (BSL),and a Modified HPLC with Doronad affinity measured the HbA1c in avenous blood sample. We used Chi-square test and SPP to analyze and process the data. The results showed 57 (57%) subjects had depression, based on BSL as many as 69 subjects (69%) were not well-controlled diabetes, HbA1c levels showed that 79 subjects (79%) were uncontrolled diabetes. Chi-Square test found a significant relationship between the incidence of depression with glycemic control in diabetic patients in the Amplas PHC (p <0.05).

  16. Comparison of three optical methods to study erythrocyte aggregation.

    PubMed

    Zhao, H; Wang, X; Stoltz, J F

    1999-01-01

    The aim of this work was to evaluate three optical methods designed to determine erythrocyte aggregation: Erythroaggregometer (EA; Regulest, France), Laser-assisted Optical Rotational Cell Analyzer (LORCA; Mechatronics, Netherlands) and Fully Automatic Erythrocyte Aggregometer (FAEA; Myrenne, GmbH, Germany). Blood samples were taken from fifty donors (26 males and 24 females). The aggregation of normal red blood cell (RBC) and RBCs suspended in three normo- and hyperaggregating suspending media was studied. The results revealed some significant correlations between parameters measured by these instruments, in particular, between the indexes of aggregation of EA and LORCA. Further, RBC aggregation of multiple myeloma patients was also studied and a hyper erythrocyte aggregation state was found by EA and LORCA.

  17. Pressure ramp programmer; IMBLMS Phase B4 Additional Tasks: Task 3.0 pressure ramp programmer

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Reinhardt, C. G.

    1972-01-01

    A pressure ramp programmer model was designed, fabricated and tested. This model, in conjunction with an automatic blood pressure monitor, automatically controls the pressure in the blood pressure monitor arterial cuff. The cuff pressurization cycle is designed to maximize accuracy and repeatability of blood pressure measurements. The key feature of this automatic cycle is rapid blood pressure cuff bleed down from an initial setting until systolic (diastolic) pressure is encountered followed by a short repressurization and slow bleed, long enough to permit accurate systolic (diastolic) pressure determination. The system includes a pressure reservoir which bleeds the cuff through a precision needle valve; a solenoid valve which permits rapid pressurization from the reservoir; and a pressure sensor which provides information for bleed rate and set point controls. Korotkoff sound signals from a microphone in the blood pressure cuff (not part of the system) provide decision information to the digital control system. The system completed a series of engineering tests using simulated Korotkoff sound inputs. The system performed successfully in all cases and was stable over an extended period of time.

  18. Validation of the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol.

    PubMed

    Chen, Wan; Zeng, Zhao-Lin; Bing, Sen; Li, Lin-Yi; Wang, Rui; Wan, Yi

    2016-08-01

    The aim of the present study was to validate the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. The ESH-IP revision 2010 for the validation of blood pressure-measuring devices in adults was followed precisely. Systolic and diastolic blood pressure (SBP and DBP, respectively) were measured sequentially in 33 adult patients and compared with a standard mercury sphygmomanometer (two observers). A total of 99 comparison pairs were obtained. The device produced 78, 95 and 99 measurements within 5, 10, and 15 mmHg for SBP and 83, 96, and 99 for DBP, respectively. The average device-observer difference was -1.81±4.22 mmHg for SBP and -0.15±3.93 mmHg for DBP. All of the data were within the standards requirements to pass the testing. The Grandway MD2301 digital automatic blood pressure monitor meets the standards of the ESH-IP revision 2010 and can be recommended for self/home measurement in the general population.

  19. Automatic blood detection in capsule endoscopy video

    NASA Astrophysics Data System (ADS)

    Novozámský, Adam; Flusser, Jan; Tachecí, Ilja; Sulík, Lukáš; Bureš, Jan; Krejcar, Ondřej

    2016-12-01

    We propose two automatic methods for detecting bleeding in wireless capsule endoscopy videos of the small intestine. The first one uses solely the color information, whereas the second one incorporates the assumptions about the blood spot shape and size. The original idea is namely the definition of a new color space that provides good separability of blood pixels and intestinal wall. Both methods can be applied either individually or their results can be fused together for the final decision. We evaluate their individual performance and various fusion rules on real data, manually annotated by an endoscopist.

  20. Fragmented red cells reference range for the Sysmex XN®-series of automated blood cell counters.

    PubMed

    Lesesve, J-F; Speyer, E; Perol, J-P

    2015-10-01

    Fragmented red cells (FRCs) are a new parameter determined automatically by the latest generation of blood cell counters. FRC counts may be of interest as they may reflect schistocyte counts measured on a stained peripheral blood smear observed under the microscope. However, FRC counts depend on the technical procedure used to detect them so that reference ranges are device dependent. The XN-9000® is one of the latest models from the Sysmex series of analysers. We aimed to establish a reference range for FRCs based on 1366 normal patient samples. The mean ± SD was 0.14 ± 0.35% and the median was 0% (95% confidence interval of the mean: 0.12-0.16%). We observed that the percentage of red blood cells with <17 pg of haemoglobin content (Hypo-He) was correlated to an FRC increase and that flagged results relating to red blood cells, reticulocytes or platelets might have presented with artefactually increased FRCs. The FRCs reference range (healthy subjects) should be useful for laboratory staff for selecting which blood smears to check optically. © 2015 John Wiley & Sons Ltd.

  1. Identification of malaria infected red blood samples by digital holographic quantitative phase microscope

    NASA Astrophysics Data System (ADS)

    Patel, Nimit R.; Chhaniwal, Vani K.; Javidi, Bahram; Anand, Arun

    2015-07-01

    Development of devices for automatic identification of diseases is desired especially in developing countries. In the case of malaria, even today the gold standard is the inspection of chemically treated blood smears through a microscope. This requires a trained technician/microscopist to identify the cells in the field of view, with which the labeling chemicals gets attached. Bright field microscopes provide only low contrast 2D images of red blood cells and cell thickness distribution cannot be obtained. Quantitative phase contrast microscopes can provide both intensity and phase profiles of the cells under study. The phase information can be used to determine thickness profile of the cell. Since cell morphology is available, many parameters pertaining to the 3D shape of the cell can be computed. These parameters in turn could be used to decide about the state of health of the cell leading to disease diagnosis. Here the investigations done on digital holographic microscope, which provides quantitative phase images, for comparison of parameters obtained from the 3D shape profile of objects leading to identification of diseased samples is described.

  2. Automated processing of whole blood samples into microliter aliquots of plasma.

    PubMed

    Burtis, C A; Johnson, W W; Walker, W A

    1988-01-01

    A rotor that accepts and automatically processes a bulk aliquot of a single blood sample into multiple aliquots of plasma has been designed and built. The rotor consists of a central processing unit, which includes a disk containing eight precision-bore capillaries. By varying the internal diameters of the capillaries, aliquot volumes ranging 1 to 10 mul can be prepared. In practice, an unmeasured volume of blood is placed in a centre well, and, as the rotor begins to spin, is moved radially into a central annular ring where it is distributed into a series of processing chambers. The rotor is then spun at 3000 rpm for 10 min. When the centrifugal field is removed by slowly decreasing the rotor speed, an aliquot of plasma is withdrawn by capillary action into each of the capillary tubes. The disk containing the eight measured aliquots of plasma is subsequently removed and placed in a modifed rotor for conventional centrifugal analysis. Initial evaluation of the new rotor indicates that it is capable of producing discrete, microliter volumes of plasma with a degree of accuracy and precision approaching that of mechanical pipettes.

  3. Red blood cell depletion from bone marrow and peripheral blood buffy coat: a comparison of two new and three established technologies.

    PubMed

    Sorg, Nadine; Poppe, Carolin; Bunos, Milica; Wingenfeld, Eva; Hümmer, Christiane; Krämer, Ariane; Stock, Belinda; Seifried, Erhard; Bonig, Halvard

    2015-06-01

    Red blood cell (RBC) depletion is a standard technique for preparation of ABO-incompatible bone marrow transplants (BMTs). Density centrifugation or apheresis are used successfully at clinical scale. The advent of a bone marrow (BM) processing module for the Spectra Optia (Terumo BCT) provided the initiative to formally compare our standard technology, the COBE2991 (Ficoll, manual, "C") with the Spectra Optia BMP (apheresis, semiautomatic, "O"), the Sepax II NeatCell (Ficoll, automatic, "S"), the Miltenyi CliniMACS Prodigy density gradient separation system (Ficoll, automatic, "P"), and manual Ficoll ("M"). C and O handle larger product volumes than S, P, and M. Technologies were assessed for RBC depletion, target cell (mononuclear cells [MNCs] for buffy coats [BCs], CD34+ cells for BM) recovery, and cost/labor. BC pools were simultaneously purged with C, O, S, and P; five to 18 BM samples were sequentially processed with C, O, S, and M. Mean RBC removal with C was 97% (BCs) or 92% (BM). From both products, O removed 97%, and P, S, and M removed 99% of RBCs. MNC recovery from BC (98% C, 97% O, 65% P, 74% S) or CD34+ cell recovery from BM (92% C, 90% O, 67% S, 70% M) were best with C and O. Polymorphonuclear cells (PMNs) were depleted from BCs by P, S, and C, while O recovered 50% of PMNs. Time savings compared to C or M for all tested technologies are considerable. All methods are in principle suitable and can be selected based on sample volume, available technology, and desired product specifications beyond RBC depletion and MNC and/or CD34+ cell recovery. © 2015 AABB.

  4. Correlation of salivary glucose level with blood glucose level in diabetes mellitus

    PubMed Central

    Gupta, Shreya; Nayak, Meghanand T; Sunitha, JD; Dawar, Geetanshu; Sinha, Nidhi; Rallan, Neelakshi Singh

    2017-01-01

    Background: Saliva is a unique fluid, which is important for normal functioning of the oral cavity. Diabetes mellitus (DM) is a disease of absolute or relative insulin deficiency characterized by insufficient secretion of insulin by pancreatic beta-cells. The diagnosis of diabetes through blood is difficult in children, older adults, debilitated and chronically ill patients, so diagnosis by analysis of saliva can be potentially valuable as collection of saliva is noninvasive, easier and technically insensitive, unlike blood. The aim of the study was to correlate blood glucose level (BGL) and salivary glucose level (SGL) in DM patients. Methodology: A cross-sectional study was conducted in 120 patients, who were categorized as 40 controlled diabetics, 40 uncontrolled diabetics and 40 healthy, age- and sex-matched individuals constituted the controls. The blood and unstimulated saliva samples were collected from the patients at the different intervals for fasting, random and postprandial levels. These samples were then subjected for analysis of glucose in blood and saliva using glucose oxidase/peroxidase reagent in HITACHI 902(R) Automatic analyzer, and the results were recorded. Results: The mean SGLs were higher in uncontrolled and controlled diabetic groups than in nondiabetic group. A highly statistically significant correlation was found between fasting saliva glucose and fasting blood glucose in all the groups. Conclusion: With increase in BGL, increase in SGL was observed in patients with diabetes suggesting that SGL can be used for monitoring glycemic level in DM. PMID:29391704

  5. Automatic blood vessel based-liver segmentation using the portal phase abdominal CT

    NASA Astrophysics Data System (ADS)

    Maklad, Ahmed S.; Matsuhiro, Mikio; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Shimada, Mitsuo; Iinuma, Gen

    2018-02-01

    Liver segmentation is the basis for computer-based planning of hepatic surgical interventions. In diagnosis and analysis of hepatic diseases and surgery planning, automatic segmentation of liver has high importance. Blood vessel (BV) has showed high performance at liver segmentation. In our previous work, we developed a semi-automatic method that segments the liver through the portal phase abdominal CT images in two stages. First stage was interactive segmentation of abdominal blood vessels (ABVs) and subsequent classification into hepatic (HBVs) and non-hepatic (non-HBVs). This stage had 5 interactions that include selective threshold for bone segmentation, selecting two seed points for kidneys segmentation, selection of inferior vena cava (IVC) entrance for starting ABVs segmentation, identification of the portal vein (PV) entrance to the liver and the IVC-exit for classifying HBVs from other ABVs (non-HBVs). Second stage is automatic segmentation of the liver based on segmented ABVs as described in [4]. For full automation of our method we developed a method [5] that segments ABVs automatically tackling the first three interactions. In this paper, we propose full automation of classifying ABVs into HBVs and non- HBVs and consequently full automation of liver segmentation that we proposed in [4]. Results illustrate that the method is effective at segmentation of the liver through the portal abdominal CT images.

  6. Construction and testing of a simple and economical soil greenhouse gas automatic sampler

    USGS Publications Warehouse

    Ginting, D.; Arnold, S.L.; Arnold, N.S.; Tubbs, R.S.

    2007-01-01

    Quantification of soil greenhouse gas emissions requires considerable sampling to account for spatial and/or temporal variation. With manual sampling, additional personnel are often not available to sample multiple sites within a narrow time interval. The objectives were to construct an automatic gas sampler and to compare the accuracy and precision of automatic versus manual sampling. The automatic sampler was tested with carbon dioxide (CO2) fluxes that mimicked the range of CO2 fluxes during a typical corn-growing season in eastern Nebraska. Gas samples were drawn from the chamber at 0, 5, and 10 min manually and with the automatic sampler. The three samples drawn with the automatic sampler were transferred to pre-vacuumed vials after 1 h; thus the samples in syringe barrels stayed connected with the increasing CO2 concentration in the chamber. The automatic sampler sustains accuracy and precision in greenhouse gas sampling while improving time efficiency and reducing labor stress. Copyright ?? Taylor & Francis Group, LLC.

  7. Blood and Bone Marrow Transplant?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  8. Blood detection in wireless capsule endoscope images based on salient superpixels.

    PubMed

    Iakovidis, Dimitris K; Chatzis, Dimitris; Chrysanthopoulos, Panos; Koulaouzidis, Anastasios

    2015-08-01

    Wireless capsule endoscopy (WCE) enables screening of the gastrointestinal (GI) tract with a miniature, optical endoscope packed within a small swallowable capsule, wirelessly transmitting color images. In this paper we propose a novel method for automatic blood detection in contemporary WCE images. Blood is an alarming indication for the presence of pathologies requiring further treatment. The proposed method is based on a new definition of superpixel saliency. The saliency of superpixels is assessed upon their color, enabling the identification of image regions that are likely to contain blood. The blood patterns are recognized by their color features using a supervised learning machine. Experiments performed on a public dataset using automatically selected first-order statistical features from various color components indicate that the proposed method outperforms state-of-the-art methods.

  9. Automatic Tortuosity-Based Retinopathy of Prematurity Screening System

    NASA Astrophysics Data System (ADS)

    Sukkaew, Lassada; Uyyanonvara, Bunyarit; Makhanov, Stanislav S.; Barman, Sarah; Pangputhipong, Pannet

    Retinopathy of Prematurity (ROP) is an infant disease characterized by increased dilation and tortuosity of the retinal blood vessels. Automatic tortuosity evaluation from retinal digital images is very useful to facilitate an ophthalmologist in the ROP screening and to prevent childhood blindness. This paper proposes a method to automatically classify the image into tortuous and non-tortuous. The process imitates expert ophthalmologists' screening by searching for clearly tortuous vessel segments. First, a skeleton of the retinal blood vessels is extracted from the original infant retinal image using a series of morphological operators. Next, we propose to partition the blood vessels recursively using an adaptive linear interpolation scheme. Finally, the tortuosity is calculated based on the curvature of the resulting vessel segments. The retinal images are then classified into two classes using segments characterized by the highest tortuosity. For an optimal set of training parameters the prediction is as high as 100%.

  10. Vessel extraction in retinal images using automatic thresholding and Gabor Wavelet.

    PubMed

    Ali, Aziah; Hussain, Aini; Wan Zaki, Wan Mimi Diyana

    2017-07-01

    Retinal image analysis has been widely used for early detection and diagnosis of multiple systemic diseases. Accurate vessel extraction in retinal image is a crucial step towards a fully automated diagnosis system. This work affords an efficient unsupervised method for extracting blood vessels from retinal images by combining existing Gabor Wavelet (GW) method with automatic thresholding. Green channel image is extracted from color retinal image and used to produce Gabor feature image using GW. Both green channel image and Gabor feature image undergo vessel-enhancement step in order to highlight blood vessels. Next, the two vessel-enhanced images are transformed to binary images using automatic thresholding before combined to produce the final vessel output. Combining the images results in significant improvement of blood vessel extraction performance compared to using individual image. Effectiveness of the proposed method was proven via comparative analysis with existing methods validated using publicly available database, DRIVE.

  11. Computer capillaroscopy as a new cardiological diagnostics method

    NASA Astrophysics Data System (ADS)

    Gurfinkel, Youri I.; Korol, Oleg A.; Kufal, George E.

    1998-04-01

    The blood flow in capillary vessels plays an important role in sustaining the vital activity of the human organism. The computerized capillaroscope is used for the investigations of nailfold (eponychium) capillary blood flow. An important advantage of the instrument is the possibility of performing non-invasive investigations, i.e., without damage to skin or vessels and causing no pain or unpleasant sensations. The high-class equipment and software allow direct observation of capillary blood flow dynamics on a computer screen at a 700 - 1300 times magnification. For the first time in the clinical practice, it has become possible to precisely measure the speed of capillary blood flow, as well as the frequency of aggregate formation (glued together in clots of blood particles). In addition, provision is made for automatic measurement of capillary size and wall thickness and automatic recording of blood aggregate images for further visual study, documentation, and electronic database management.

  12. Computed aided system for separation and classification of the abnormal erythrocytes in human blood

    NASA Astrophysics Data System (ADS)

    Wąsowicz, Michał; Grochowski, Michał; Kulka, Marek; Mikołajczyk, Agnieszka; Ficek, Mateusz; Karpieńko, Katarzyna; Cićkiewicz, Maciej

    2017-12-01

    The human peripheral blood consists of cells (red cells, white cells, and platelets) suspended in plasma. In the following research the team assessed an influence of nanodiamond particles on blood elements over various periods of time. The material used in the study consisted of samples taken from ten healthy humans of various age, different blood types and both sexes. The markings were leaded by adding to the blood unmodified diamonds and oxidation modified. The blood was put under an impact of two diamond concentrations: 20μl and 100μl. The amount of abnormal cells increased with time. The percentage of echinocytes as a result of interaction with nanodiamonds in various time intervals for individual specimens was scarce. The impact of the two diamond types had no clinical importance on red blood cells. It is supposed that as a result of longlasting exposure a dehydratation of red cells takes place, because of the function of the cells. The analysis of an influence of nanodiamond particles on blood elements was supported by computer system designed for automatic counting and classification of the Red Blood Cells (RBC). The system utilizes advanced image processing methods for RBCs separation and counting and Eigenfaces method coupled with the neural networks for RBCs classification into normal and abnormal cells purposes.

  13. Small and cheap: accurate differential blood count with minimal sample volume by laser scanning cytometry (LSC)

    NASA Astrophysics Data System (ADS)

    Mittag, Anja; Lenz, Dominik; Smith, Paul J.; Pach, Susanne; Tarnok, Attila

    2005-04-01

    Aim: In patients, e.g. with congenital heart diseases, a differential blood count is needed for diagnosis. To this end by standard automatic analyzers 500 μl of blood is required from the patients. In case of newborns and infants this is a substantial volume, especially after operations associated with blood loss. Therefore, aim of this study was to develop a method to determine a differential blood picture with a substantially reduced specimen volume. Methods: To generate a differential blood picture 10 μl EDTA blood were mixed with 10 μl of a DRAQ5 solution (500μM, Biostatus) and 10 μl of an antibody mixture (CD45-FITC, CD14-PE, diluted with PBS). 20 μl of this cell suspension was filled into a Neubauer counting chamber. Due to the defined volume of the chamber it is possible to determine the cell count per volume. The trigger for leukocyte counting was set on DRAQ5 signal in order to be able to distinguish nucleated white blood cells from erythrocytes. Different leukocyte subsets could be distinguished due to the used fluorescence labeled antibodies. For erythrocyte counting cell suspension was diluted another 150 times. 20 μl of this dilution was analyzed in a microchamber by LSC with trigger set on forward scatter signal. Results: This method allows a substantial decrease of blood sample volume for generation of a differential blood picture (10 μl instead of 500μl). There was a high correlation between our method and the results of routine laboratory (r2=0.96, p<0.0001 n=40). For all parameters intra-assay variance was less than 7 %. Conclusions: In patients with low blood volume such as neonates and in critically ill infants every effort has to be taken to reduce the blood volume needed for diagnostics. With this method only 2% of standard sample volume is needed to generate a differential blood picture. Costs are below that of routine laboratory. We suggest this method to be established in paediatric cardiology for routine diagnostics and for resource poor settings.

  14. Screening for Atrial Fibrillation in Patients ≥65 Years Using an Automatic Blood Pressure Monitor in a Skilled Nursing Facility.

    PubMed

    Wiesel, Joseph; Salomone, Thomas J

    2017-10-15

    Early detection of asymptomatic atrial fibrillation (AF) provides an opportunity to treat patients to reduce their risk of stroke. Long-term residents of skilled nursing facilities frequently have multiple risk factors for strokes due to AF and may benefit from screening for AF. Patients in a skilled nursing facility 65 years and older, without a history of AF and without a pacemaker or defibrillator, were evaluated using a Microlife WatchBP Home A automatic blood pressure monitor that can detect AF when set to a triple reading mode. Those with readings positive for AF were evaluated with a standard 12-lead electrocardiogram (ECG) or a 30-second single-channel ECG to confirm the presence of AF. A total of 101 patients were screened with an average age of 78 years, and 48 (48%) were female. Nine automatic blood pressure monitor readings were positive for possible AF. Of those, 7 (6.9%, 95% confidence intervals 3.0% to 14.2%) had AF confirmed with ECG. Only 2 (2%, 95% confidence interval 0.3% to 7.7%) were false-positive readings. One-time screening for AF using an automatic blood pressure monitor in a skilled nursing facility resulted in a high number of patients with newly diagnosed AF. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Automatic blood pressure measuring system (M092)

    NASA Technical Reports Server (NTRS)

    Nolte, R. W.

    1977-01-01

    The Blood Pressure Measuring System is described. It measures blood pressure by the noninvasive Korotkoff sound technique on a continual basis as physical stress is imposed during experiment M092, Lower Body Negative Pressure, and experiment M171, Metabolic Activity.

  16. Comparison of the quantification of acetaminophen in plasma, cerebrospinal fluid and dried blood spots using high-performance liquid chromatography-tandem mass spectrometry

    PubMed Central

    Taylor, Rachel R.; Hoffman, Keith L.; Schniedewind, Björn; Clavijo, Claudia; Galinkin, Jeffrey L.; Christians, Uwe

    2013-01-01

    Acetaminophen (paracetamol, N-(4-hydroxyphenyl) acetamide) is one of the most commonly prescribed drugs for the management of pain in children. Quantification of acetaminophen in pre-term and term neonates and small children requires the availability of highly sensitive assays in small volume blood samples. We developed and validated an LC-MS/MS assay for the quantification of acetaminophen in human plasma, cerebro-spinal fluid (CSF) and dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the deuterated internal standard were the only manual steps. Extracted samples were analyzed on a Kinetex 2.6 μm PFP column using an acetonitrile/formic acid gradient. The analytes were detected in the positive multiple reaction mode. Alternatively, DBS were automatically processed using direct desorption in a sample card and preparation (SCAP) robotic autosampler in combination with online extraction. The range of reliable response in plasma and CSF was 3.05-20,000 ng/ml (r2 > 0.99) and 27.4-20,000 ng/ml (r2 > 0.99) for DBS (manual extraction and automated direct desorption). Inter-day accuracy was always within 85-115% and inter-day precision for plasma, CSF and manually extracted DBS were less than 15%. Deming regression analysis comparing 167 matching pairs of plasma and DBS samples showed a correlation coefficient of 0.98. Bland Altman analysis indicated a 26.6% positive bias in DBS, most likely reflecting the blood: plasma distribution ratio of acetaminophen. DBS are a valid matrix for acetaminophen pharmacokinetic studies. PMID:23670126

  17. Automated Blood Pressure Measurement

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The Vital-2 unit pictured is a semi-automatic device that permits highly accurate blood pressure measurement, even by untrained personnel. Developed by Meditron Instrument Corporation, Milford, New Hampshire, it is based in part on NASA technology found in a similar system designed for automatic monitoring of astronauts' blood pressure. Vital-2 is an advancement over the familiar arm cuff, dial and bulb apparatus customarily used for blood pressure checks. In that method, the physician squeezes the bulb to inflate the arm cuff, which restricts the flow of blood through the arteries. As he eases the pressure on the arm, he listens, through a stethoscope, to the sounds of resumed blood flow as the arteries expand and contract. Taking dial readings related to sound changes, he gets the systolic (contracting) and diastolic (expanding) blood pressure measurements. The accuracy of the method depends on the physician's skill in interpreting the sounds. Hospitals sometimes employ a more accurate procedure, but it is "invasive," involving insertion of a catheter in the artery.

  18. Automatic real time evaluation of red blood cell elasticity by optical tweezers

    NASA Astrophysics Data System (ADS)

    Moura, Diógenes S.; Silva, Diego C. N.; Williams, Ajoke J.; Bezerra, Marcos A. C.; Fontes, Adriana; de Araujo, Renato E.

    2015-05-01

    Optical tweezers have been used to trap, manipulate, and measure individual cell properties. In this work, we show that the association of a computer controlled optical tweezers system with image processing techniques allows rapid and reproducible evaluation of cell deformability. In particular, the deformability of red blood cells (RBCs) plays a key role in the transport of oxygen through the blood microcirculation. The automatic measurement processes consisted of three steps: acquisition, segmentation of images, and measurement of the elasticity of the cells. An optical tweezers system was setup on an upright microscope equipped with a CCD camera and a motorized XYZ stage, computer controlled by a Labview platform. On the optical tweezers setup, the deformation of the captured RBC was obtained by moving the motorized stage. The automatic real-time homemade system was evaluated by measuring RBCs elasticity from normal donors and patients with sickle cell anemia. Approximately 150 erythrocytes were examined, and the elasticity values obtained by using the developed system were compared to the values measured by two experts. With the automatic system, there was a significant time reduction (60 × ) of the erythrocytes elasticity evaluation. Automated system can help to expand the applications of optical tweezers in hematology and hemotherapy.

  19. Automatic retinal blood flow calculation using spectral domain optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Wehbe, Hassan; Ruggeri, Marco; Jiao, Shuliang; Gregori, Giovanni; Puliafito, Carmen A.

    2008-02-01

    Optical Doppler tomography (ODT) is a branch of optical coherence tomography (OCT) that can measure the speed of a blood flow by measuring the Doppler shift impinged on the probing sample light by the moving blood cells. However, the measured speed of blood flow is a function of the Doppler angle, which needs to be determined in order to calculate the absolute velocity of the blood flow inside a vessel. We developed a technique that can extract the Doppler angle from the 3D data measured with spectral-domain OCT, which needs to extract the lateral and depth coordinates of a vessel in each measured ODT and OCT image. The lateral coordinates and the diameter of a blood vessel were first extracted in each OCT structural image by using the technique of blood vessel shadowgram, a technique first developed by us for enhancing the retinal blood vessel contrast in the en face view of the 3D OCT. The depth coordinate of a vessel was then determined by using a circular averaging filter moving in the depth direction along the axis passing through the vessel center in the ODT image. The Doppler angle was then calculated from the extracted coordinates of the blood vessel. The technique was applied in blood flow measurements in retinal blood vessels, which has potential impact on the study and diagnosis of blinding diseases like glaucoma and diabetic retinopathy.

  20. Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Guo, Wan-Gang; Li, Bing-Ling; He, Yong; Xue, Yu-Sheng; Wang, Hai-Yan; Zheng, Qiang-Sun; Xiang, Ding-Cheng

    2014-08-01

    To validate the Andon KD-5917 automatic upper arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Sequential same-left-arm measurements of systolic blood pressure (SBP) and diastolic blood pressure (DBP) were obtained in 33 participants using the mercury sphygmomanometer and the test device. According to the validation protocol, 99 pairs of test device and reference blood pressure measurements (three pairs for each of the 33 participants) were obtained in the study. The device produced 73, 98, and 99 measurements within 5, 10, and 15 mmHg for SBP and 86, 98, and 99 for DBP, respectively. The mean ± SD device-observer difference was 3.07 ± 3.68 mmHg for SBP and -0.89 ± 3.72 mmHg for DBP. The number of patients with two or three of the device-observer difference within 5 mmHg was 26 for SBP and 29 for DBP, and no patient had a device-observer difference within 5 mmHg. The Andon KD-5917 automatic upper arm blood pressure monitor can be recommended for clinical use and self-measurement in an adult population on the basis of the European Society of Hypertension International Protocol revision 2010.

  1. Improving left ventricular segmentation in four-dimensional flow MRI using intramodality image registration for cardiac blood flow analysis.

    PubMed

    Gupta, Vikas; Bustamante, Mariana; Fredriksson, Alexandru; Carlhäll, Carl-Johan; Ebbers, Tino

    2018-01-01

    Assessment of blood flow in the left ventricle using four-dimensional flow MRI requires accurate left ventricle segmentation that is often hampered by the low contrast between blood and the myocardium. The purpose of this work is to improve left-ventricular segmentation in four-dimensional flow MRI for reliable blood flow analysis. The left ventricle segmentations are first obtained using morphological cine-MRI with better in-plane resolution and contrast, and then aligned to four-dimensional flow MRI data. This alignment is, however, not trivial due to inter-slice misalignment errors caused by patient motion and respiratory drift during breath-hold based cine-MRI acquisition. A robust image registration based framework is proposed to mitigate such errors automatically. Data from 20 subjects, including healthy volunteers and patients, was used to evaluate its geometric accuracy and impact on blood flow analysis. High spatial correspondence was observed between manually and automatically aligned segmentations, and the improvements in alignment compared to uncorrected segmentations were significant (P < 0.01). Blood flow analysis from manual and automatically corrected segmentations did not differ significantly (P > 0.05). Our results demonstrate the efficacy of the proposed approach in improving left-ventricular segmentation in four-dimensional flow MRI, and its potential for reliable blood flow analysis. Magn Reson Med 79:554-560, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  2. Simultaneous validation of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society and the Association for the Advancement of Medical Instrumentation/the International Organization for Standardization protocols.

    PubMed

    Huang, Jinhua; Wang, Yun; Liu, Zhaoying; Wang, Yuling

    2017-02-01

    The aim of this study was to determine the accuracy of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI)/the International Organization for Standardization (ISO) protocols. A total of 85 participants were included for evaluation based on the requirements of the BHS and the AAMI/ISO protocols. The validation procedure and data analysis followed the protocols precisely. The device achieved A/A grading for the BHS protocol and maintained A/A grading throughout the low, medium and high blood pressure ranges. The device also fulfilled the requirement of the AAMI/ISO protocol with device-observer differences of -0.9±5.6 and 0.8±5.2 mmHg for systolic and diastolic blood pressure, respectively, for criterion 1, and -0.9±4.7 and 0.8±4.2 mmHg, respectively, for criterion 2. The Grandway MD2301 digital automatic blood pressure monitor achieved A/A grade of the BHS protocol and passed the requirements of the AAMI/ISO protocol in adults.

  3. Fresenius AS.TEC204 blood cell separator.

    PubMed

    Sugai, Mikiya

    2003-02-01

    Fresenius AS.TEC204 is a third-generation blood cell separator that incorporates the continuous centrifugal separation method and automatic control of the cell separation process. Continuous centrifugation separates cell components according to their specific gravity, and different cell components are either harvested or eliminated as needed. The interface between the red blood cell and plasma is optically detected, and the Interface Control (IFC) cooperates with different pumps, monitors and detectors to harvest required components automatically. The system is composed of three major sections; the Front Panel Unit; the Pump Unit, and the Centrifuge Unit. This unit can be used for a wide variety of clinical applications including collection of platelets, peripheral blood stem cells, bone marrow stem cells, granulocytes, mononuclear cells, and exchange of plasma or red cells, and for plasma treatment.

  4. Assessment of myocardial metabolic rate of glucose by means of Bayesian ICA and Markov Chain Monte Carlo methods in small animal PET imaging

    NASA Astrophysics Data System (ADS)

    Berradja, Khadidja; Boughanmi, Nabil

    2016-09-01

    In dynamic cardiac PET FDG studies the assessment of myocardial metabolic rate of glucose (MMRG) requires the knowledge of the blood input function (IF). IF can be obtained by manual or automatic blood sampling and cross calibrated with PET. These procedures are cumbersome, invasive and generate uncertainties. The IF is contaminated by spillover of radioactivity from the adjacent myocardium and this could cause important error in the estimated MMRG. In this study, we show that the IF can be extracted from the images in a rat heart study with 18F-fluorodeoxyglucose (18F-FDG) by means of Independent Component Analysis (ICA) based on Bayesian theory and Markov Chain Monte Carlo (MCMC) sampling method (BICA). Images of the heart from rats were acquired with the Sherbrooke small animal PET scanner. A region of interest (ROI) was drawn around the rat image and decomposed into blood and tissue using BICA. The Statistical study showed that there is a significant difference (p < 0.05) between MMRG obtained with IF extracted by BICA with respect to IF extracted from measured images corrupted with spillover.

  5. Automatic detection of blood vessels in retinal images for diabetic retinopathy diagnosis.

    PubMed

    Raja, D Siva Sundhara; Vasuki, S

    2015-01-01

    Diabetic retinopathy (DR) is a leading cause of vision loss in diabetic patients. DR is mainly caused due to the damage of retinal blood vessels in the diabetic patients. It is essential to detect and segment the retinal blood vessels for DR detection and diagnosis, which prevents earlier vision loss in diabetic patients. The computer aided automatic detection and segmentation of blood vessels through the elimination of optic disc (OD) region in retina are proposed in this paper. The OD region is segmented using anisotropic diffusion filter and subsequentially the retinal blood vessels are detected using mathematical binary morphological operations. The proposed methodology is tested on two different publicly available datasets and achieved 93.99% sensitivity, 98.37% specificity, 98.08% accuracy in DRIVE dataset and 93.6% sensitivity, 98.96% specificity, and 95.94% accuracy in STARE dataset, respectively.

  6. Automatic sample Dewar for MX beam-line

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Charignon, T.; Tanchon, J.; Trollier, T.

    2014-01-29

    It is very common for crystals of large biological macromolecules to show considerable variation in quality of their diffraction. In order to increase the number of samples that are tested for diffraction quality before any full data collections at the ESRF*, an automatic sample Dewar has been implemented. Conception and performances of the Dewar are reported in this paper. The automatic sample Dewar has 240 samples capability with automatic loading/unloading ports. The storing Dewar is capable to work with robots and it can be integrated in a full automatic MX** beam-line. The samples are positioned in the front of themore » loading/unloading ports with and automatic rotating plate. A view port has been implemented for data matrix camera reading on each sample loaded in the Dewar. At last, the Dewar is insulated with polyurethane foam that keeps the liquid nitrogen consumption below 1.6 L/h. At last, the static insulation also makes vacuum equipment and maintenance unnecessary. This Dewar will be useful for increasing the number of samples tested in synchrotrons.« less

  7. Portable automatic blood analyzer

    NASA Technical Reports Server (NTRS)

    Coleman, R. L.

    1975-01-01

    Analyzer employs chemical-sensing electrodes for determination of blood, gas, and ion concentrations. It is rugged, easily serviced, and comparatively simple to operate. System can analyze up to eight parameters and can be modified to measure other blood constituents including nonionic species, such as urea, glucose, and oxygen.

  8. Application of implicit attitude measures to the blood donation context.

    PubMed

    Warfel, Regina M; France, Christopher R; France, Janis L

    2012-02-01

    Past blood donation research has relied on explicit (self-report) measures to understand blood donation motivations, but has not yet considered the inherent implicit or automatic processing involved in decision-making. This study addresses this limitation by introducing and validating two novel implicit measures of blood donation attitudes. Healthy young adults (n = 253) performed both image and word versions of a Single Target Implicit Association Test (ST-IAT) and then completed self-report measures of blood donation attitudes, blood and needle fears, social desirability, and donation intention. These results affirmed the validity of the blood donation ST-IATs in at least three ways. First, as expected, nondonors demonstrated more negative implicit donation attitudes than donors. Second, the implicit measures were significantly related in expected directions with explicit measures of donation attitudes as well as blood and needle fears. Finally, implicit donation attitudes were significantly related to donation intention, and the Image ST-IAT (but not the Word ST-IAT) significantly enhanced prediction of donation intention over and above needle fears and marginally enhanced prediction over and above blood fears. Image and word versions of the blood donation ST-IAT offer a valid method of assessing underlying automatic attitudes toward blood donation. © 2012 American Association of Blood Banks.

  9. New algorithm for detecting smaller retinal blood vessels in fundus images

    NASA Astrophysics Data System (ADS)

    LeAnder, Robert; Bidari, Praveen I.; Mohammed, Tauseef A.; Das, Moumita; Umbaugh, Scott E.

    2010-03-01

    About 4.1 million Americans suffer from diabetic retinopathy. To help automatically diagnose various stages of the disease, a new blood-vessel-segmentation algorithm based on spatial high-pass filtering was developed to automatically segment blood vessels, including the smaller ones, with low noise. Methods: Image database: Forty, 584 x 565-pixel images were collected from the DRIVE image database. Preprocessing: Green-band extraction was used to obtain better contrast, which facilitated better visualization of retinal blood vessels. A spatial highpass filter of mask-size 11 was applied. A histogram stretch was performed to enhance contrast. A median filter was applied to mitigate noise. At this point, the gray-scale image was converted to a binary image using a binary thresholding operation. Then, a NOT operation was performed by gray-level value inversion between 0 and 255. Postprocessing: The resulting image was AND-ed with its corresponding ring mask to remove the outer-ring (lens-edge) artifact. At this point, the above algorithm steps had extracted most of the major and minor vessels, with some intersections and bifurcations missing. Vessel segments were reintegrated using the Hough transform. Results: After applying the Hough transform, both the average peak SNR and the RMS error improved by 10%. Pratt's Figure of Merit (PFM) was decreased by 6%. Those averages were better than [1] by 10-30%. Conclusions: The new algorithm successfully preserved the details of smaller blood vessels and should prove successful as a segmentation step for automatically identifying diseases that affect retinal blood vessels.

  10. ASAP (Automatic Software for ASL Processing): A toolbox for processing Arterial Spin Labeling images.

    PubMed

    Mato Abad, Virginia; García-Polo, Pablo; O'Daly, Owen; Hernández-Tamames, Juan Antonio; Zelaya, Fernando

    2016-04-01

    The method of Arterial Spin Labeling (ASL) has experienced a significant rise in its application to functional imaging, since it is the only technique capable of measuring blood perfusion in a truly non-invasive manner. Currently, there are no commercial packages for processing ASL data and there is no recognized standard for normalizing ASL data to a common frame of reference. This work describes a new Automated Software for ASL Processing (ASAP) that can automatically process several ASL datasets. ASAP includes functions for all stages of image pre-processing: quantification, skull-stripping, co-registration, partial volume correction and normalization. To assess the applicability and validity of the toolbox, this work shows its application in the study of hypoperfusion in a sample of healthy subjects at risk of progressing to Alzheimer's disease. ASAP requires limited user intervention, minimizing the possibility of random and systematic errors, and produces cerebral blood flow maps that are ready for statistical group analysis. The software is easy to operate and results in excellent quality of spatial normalization. The results found in this evaluation study are consistent with previous studies that find decreased perfusion in Alzheimer's patients in similar regions and demonstrate the applicability of ASAP. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Comparison of the quantification of acetaminophen in plasma, cerebrospinal fluid and dried blood spots using high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Taylor, Rachel R; Hoffman, Keith L; Schniedewind, Björn; Clavijo, Claudia; Galinkin, Jeffrey L; Christians, Uwe

    2013-09-01

    Acetaminophen (paracetamol, N-(4-hydroxyphenyl) acetamide) is one of the most commonly prescribed drugs for the management of pain in children. Quantification of acetaminophen in pre-term and term neonates and small children requires the availability of highly sensitive assays in small volume blood samples. We developed and validated an LC-MS/MS assay for the quantification of acetaminophen in human plasma, cerebro-spinal fluid (CSF) and dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the deuterated internal standard were the only manual steps. Extracted samples were analyzed on a Kinetex 2.6 μm PFP column using an acetonitrile/formic acid gradient. The analytes were detected in the positive multiple reaction mode. Alternatively, DBS were automatically processed using direct desorption in a sample card and preparation (SCAP) robotic autosampler in combination with online extraction. The range of reliable response in plasma and CSF was 3.05-20,000 ng/ml (r(2)>0.99) and 27.4-20,000 ng/ml (r(2)>0.99) for DBS (manual extraction and automated direct desorption). Inter-day accuracy was always within 85-115% and inter-day precision for plasma, CSF and manually extracted DBS were less than 15%. Deming regression analysis comparing 167 matching pairs of plasma and DBS samples showed a correlation coefficient of 0.98. Bland Altman analysis indicated a 26.6% positive bias in DBS, most likely reflecting the blood: plasma distribution ratio of acetaminophen. DBS are a valid matrix for acetaminophen pharmacokinetic studies. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. A hybrid 3D region growing and 4D curvature analysis-based automatic abdominal blood vessel segmentation through contrast enhanced CT

    NASA Astrophysics Data System (ADS)

    Maklad, Ahmed S.; Matsuhiro, Mikio; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Shimada, Mitsuo; Iinuma, Gen

    2017-03-01

    In abdominal disease diagnosis and various abdominal surgeries planning, segmentation of abdominal blood vessel (ABVs) is a very imperative task. Automatic segmentation enables fast and accurate processing of ABVs. We proposed a fully automatic approach for segmenting ABVs through contrast enhanced CT images by a hybrid of 3D region growing and 4D curvature analysis. The proposed method comprises three stages. First, candidates of bone, kidneys, ABVs and heart are segmented by an auto-adapted threshold. Second, bone is auto-segmented and classified into spine, ribs and pelvis. Third, ABVs are automatically segmented in two sub-steps: (1) kidneys and abdominal part of the heart are segmented, (2) ABVs are segmented by a hybrid approach that integrates a 3D region growing and 4D curvature analysis. Results are compared with two conventional methods. Results show that the proposed method is very promising in segmenting and classifying bone, segmenting whole ABVs and may have potential utility in clinical use.

  13. AMBULATORY BLOOD PRESSURE MONITORING: THE NEED OF 7-DAY RECORD

    PubMed Central

    HALBERG, F.; KATINAS, G.; CORNÉLISSEN, G.; SCHWARTZKOPFF, O.; FIŠER, B.; SIEGELOVÁ, J.; DUŠEK, J.; JANČÍK, J.

    2008-01-01

    The need for systematic around-the-clock self-measurements of blood pressure (BP) and heart rate (HR), or preferably for automatic monitoring as the need arises and can be met by inexpensive tools, is illustrated in two case reports. Miniaturized unobtrusive, as yet unavailable instrumentation for the automatic measurement of BP and HR should be a high priority for both government and industry. Automatic ambulatorily functioning monitors already represent great progress, enabling us to introduce the concept of eventually continuous or, as yet, intermittent home ABPM. On BP and HR records, gliding spectra aligned with global spectra visualize the changing dynamics involved in health and disease, and can be part of an eventually automated system of therapy adjusted to the ever-present variability of BP. In the interim, with tools already available, chronomics on self- or automatic measurements can be considered, with analyses provided by the Halberg Chronobiology Center, as an alternative to “flying blind”, as an editor put it. Chronomics assessing variability has to be considered. PMID:19018289

  14. Flow Quantification from 2D Phase Contrast MRI in Renal Arteries Using Clustering

    NASA Astrophysics Data System (ADS)

    Zöllner, Frank G.; Monnsen, Jan Ankar; Lundervold, Arvid; Rørvik, Jarle

    We present an approach based on clustering to segment renal arteries from 2D PC Cine MR images to measure blood velocity and flow. Such information are important in grading renal artery stenosis and support the decision on surgical interventions like percutan transluminal angioplasty. Results show that the renal arteries could be extracted automatically and the corresponding velocity profiles could be calculated. Furthermore, the clustering could detect possible phase wrap effects automatically as well as differences in the blood flow patterns within the vessel.

  15. Automated analysis of blood pressure measurements (Korotkov sound)

    NASA Technical Reports Server (NTRS)

    Golden, D. P.; Hoffler, G. W.; Wolthuis, R. A.

    1972-01-01

    Automatic system for noninvasive measurements of arterial blood pressure is described. System uses Korotkov sound processor logic ratios to identify Korotkov sounds. Schematic diagram of system is provided to show components and method of operation.

  16. Automatic blood pressure measuring system (M091)

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The Leg Volume Measuring System is used to measure leg calf girth changes that occur during exposure to lower body negative pressure as a result of pooling of blood and other fluids in the lower extremities.

  17. Fixing clearance as early as lead optimization using high throughput in vitro incubations in combination with exact mass detection and automatic structure elucidation of metabolites.

    PubMed

    Zimmerlin, Alfred; Kiffe, Michael

    2013-01-01

    New enabling MS technologies have made it possible to elucidate metabolic pathways present in ex vivo (blood, bile and/or urine) or in vitro (liver microsomes, hepatocytes and/or S9) samples. When investigating samples from high throughput assays the challenge that the user is facing now is to extract the appropriate information and compile it so that it is understandable to all. Medicinal chemist may then design the next generation of (better) drug candidates combining the needs for potency and metabolic stability and their synthetic creativity. This review focuses on the comparison of these enabling MS technologies and the IT tools developed for their interpretation.

  18. Fully automatic multi-atlas segmentation of CTA for partial volume correction in cardiac SPECT/CT

    NASA Astrophysics Data System (ADS)

    Liu, Qingyi; Mohy-ud-Din, Hassan; Boutagy, Nabil E.; Jiang, Mingyan; Ren, Silin; Stendahl, John C.; Sinusas, Albert J.; Liu, Chi

    2017-05-01

    Anatomical-based partial volume correction (PVC) has been shown to improve image quality and quantitative accuracy in cardiac SPECT/CT. However, this method requires manual segmentation of various organs from contrast-enhanced computed tomography angiography (CTA) data. In order to achieve fully automatic CTA segmentation for clinical translation, we investigated the most common multi-atlas segmentation methods. We also modified the multi-atlas segmentation method by introducing a novel label fusion algorithm for multiple organ segmentation to eliminate overlap and gap voxels. To evaluate our proposed automatic segmentation, eight canine 99mTc-labeled red blood cell SPECT/CT datasets that incorporated PVC were analyzed, using the leave-one-out approach. The Dice similarity coefficient of each organ was computed. Compared to the conventional label fusion method, our proposed label fusion method effectively eliminated gaps and overlaps and improved the CTA segmentation accuracy. The anatomical-based PVC of cardiac SPECT images with automatic multi-atlas segmentation provided consistent image quality and quantitative estimation of intramyocardial blood volume, as compared to those derived using manual segmentation. In conclusion, our proposed automatic multi-atlas segmentation method of CTAs is feasible, practical, and facilitates anatomical-based PVC of cardiac SPECT/CT images.

  19. Highly automatic quantification of myocardial oedema in patients with acute myocardial infarction using bright blood T2-weighted CMR

    PubMed Central

    2013-01-01

    Background T2-weighted cardiovascular magnetic resonance (CMR) is clinically-useful for imaging the ischemic area-at-risk and amount of salvageable myocardium in patients with acute myocardial infarction (MI). However, to date, quantification of oedema is user-defined and potentially subjective. Methods We describe a highly automatic framework for quantifying myocardial oedema from bright blood T2-weighted CMR in patients with acute MI. Our approach retains user input (i.e. clinical judgment) to confirm the presence of oedema on an image which is then subjected to an automatic analysis. The new method was tested on 25 consecutive acute MI patients who had a CMR within 48 hours of hospital admission. Left ventricular wall boundaries were delineated automatically by variational level set methods followed by automatic detection of myocardial oedema by fitting a Rayleigh-Gaussian mixture statistical model. These data were compared with results from manual segmentation of the left ventricular wall and oedema, the current standard approach. Results The mean perpendicular distances between automatically detected left ventricular boundaries and corresponding manual delineated boundaries were in the range of 1-2 mm. Dice similarity coefficients for agreement (0=no agreement, 1=perfect agreement) between manual delineation and automatic segmentation of the left ventricular wall boundaries and oedema regions were 0.86 and 0.74, respectively. Conclusion Compared to standard manual approaches, the new highly automatic method for estimating myocardial oedema is accurate and straightforward. It has potential as a generic software tool for physicians to use in clinical practice. PMID:23548176

  20. Unanticipated error in HbA(1c) measurement on the HLC-723 G7 analyzer.

    PubMed

    van den Ouweland, Johannes M W; de Keijzer, Marinus H; van Daal, Henny

    2010-04-01

    Investigation of falsely elevated HbA(1c) measurements on the HLC-723 G7 analyser. Comparison of HbA(1c) in blood samples that were diluted either in hemolysis reagent or water. HbA(1c) results became falsely elevated when samples were diluted in hemolysis reagent, but not in water. QC-procedures failed to detect this error as calibrator and QC samples were manually diluted in water, according to manufacturer's instructions, whereas patient samples were automatically diluted using hemolysing reagent. After replacement of the instruments' sample-loop and rotor seal comparable HbA(1c) results were obtained, irrespective of dilution with hemolysing reagent or water. This case illustrates the importance of treating calibrator and QC materials similar to routine patient samples in order to prevent unnoticed drift in patient HbA(1c) results. Copyright 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  1. Diagnostic applications of an optoelectronic device for high temporal resolution of erythrocyte sedimentation (ESR-graphy)

    NASA Astrophysics Data System (ADS)

    Voeikov, Vladimir L.; Buravleva, Ekaterina; Bulargina, Yulia; Gurfinkel, Youri I.

    2001-10-01

    An automatic device for high-temporal resolution of the process of erythrocytes sedimentation in blood was designed. The position of the boundary between red blood and plasma is registered each 30 sec in several pipettes simultaneously with +/- 10 mkm precision. Data are processed by a PC and presented as velocity-time curves (ESR-grams) and the curves describing time evolution of the boundary position. ESR-grams demonstrate non-monotonous character of erythrocytes sedimentation in blood. Blood of particular donor being in a stable physiological state taken on different days is characterized by similar ESR-grams. Pathological deviations from a normal physiological state are reflected in the shortening of duration of each process stage and increasing of average sedimentation rate. Intravenous infusion of some medical preparations may lead either to improving (prolonging of macrokinetic stages, decreasing of sedimentation rate), or to worsening of studied parameters depending on an individual. The low extent of blood dilution with saline in vitro lead as a rule to decreasing of sedimentation rate and improving of microkinetic parameters of the process. Adding of highly diluted hydrogen peroxide to blood samples of patients resulted in the improving of sedimentation kinetics. ESR-graphy may widen opportunities of practical medicine in diagnostics, prognostics and drug therapy.

  2. Multicommuted flow system for the determination of glucose in animal blood serum exploiting enzymatic reaction and chemiluminescence detection

    PubMed Central

    Pires, Cherrine K.; Martelli, Patrícia B.; Lima, José L. F. C.; Saraiva, Maria Lúcia M. F. S.

    2003-01-01

    An automatic flow procedure based on multicommutation dedicated for the determination of glucose in animal blood serum using glucose oxidase with chemiluminescence detection is described. The flow manifold consisted of a set of three-way solenoid valves assembled to implement multicommutation. A microcomputer furnished with an electronic interface and software written in Quick BASIC 4.5 controlled the manifold and performed data acquisition. Glucose oxidase was immobilized on porous silica beads (glass aminopropyl) and packed in a minicolumn (15 × 5 mm). The procedure was based on the enzymatic degradation of glucose, producing hydrogen peroxide, which oxidized luminol in the presence of hexacyanoferrate(III), causing the chemiluminescence. The system was tested by analysing a set of serum animal samples without previous treatment. Results were in agreement with those obtained with the conventional method (LABTEST Kit) at the 95% confidence level. The detection limit and variation coefficient were estimated as 12.0 mg l−1 (99.7% confidence level) and 3.5% (n = 20), respectively. The sampling rate was about 60 determinations h−1 with sample concentrations ranging from 50 to 600 mg l−1 glucose. The consumptions of serum sample, hexacyanoferrate(III) and luminol were 46 μl, 10.0 mg and 0.2 mg/determination, respectively. PMID:18924619

  3. Image processing and machine learning in the morphological analysis of blood cells.

    PubMed

    Rodellar, J; Alférez, S; Acevedo, A; Molina, A; Merino, A

    2018-05-01

    This review focuses on how image processing and machine learning can be useful for the morphological characterization and automatic recognition of cell images captured from peripheral blood smears. The basics of the 3 core elements (segmentation, quantitative features, and classification) are outlined, and recent literature is discussed. Although red blood cells are a significant part of this context, this study focuses on malignant lymphoid cells and blast cells. There is no doubt that these technologies may help the cytologist to perform efficient, objective, and fast morphological analysis of blood cells. They may also help in the interpretation of some morphological features and may serve as learning and survey tools. Although research is still needed, it is important to define screening strategies to exploit the potential of image-based automatic recognition systems integrated in the daily routine of laboratories along with other analysis methodologies. © 2018 John Wiley & Sons Ltd.

  4. Sample processor for the automatic extraction of families of compounds from liquid samples and/or homogenized solid samples suspended in a liquid

    NASA Technical Reports Server (NTRS)

    Jahnsen, Vilhelm J. (Inventor); Campen, Jr., Charles F. (Inventor)

    1980-01-01

    A sample processor and method for the automatic extraction of families of compounds, known as extracts, from liquid and/or homogenized solid samples are disclosed. The sample processor includes a tube support structure which supports a plurality of extraction tubes, each containing a sample from which families of compounds are to be extracted. The support structure is moveable automatically with respect to one or more extraction stations, so that as each tube is at each station a solvent system, consisting of a solvent and reagents, is introduced therein. As a result an extract is automatically extracted from the tube. The sample processor includes an arrangement for directing the different extracts from each tube to different containers, or to direct similar extracts from different tubes to the same utilization device.

  5. What Are the Safety Considerations for Insulin Control for Athletes?

    ERIC Educational Resources Information Center

    McDaniel, Larry W.; Olson, Sara; Gaudet, Laura; Jackson, Allen

    2010-01-01

    Athletes diagnosed with diabetes may have difficulty with their blood sugar levels fluctuating during intense exercise. Considerations for athletes with insulin concerns may range anywhere from exercise rehabilitation to the use of an automatic insulin pump. The automatic insulin pump is a small battery-operated device about the size of a pager.…

  6. Automatic and Reproducible Positioning of Phase-Contrast MRI for the Quantification of Global Cerebral Blood Flow

    PubMed Central

    Liu, Peiying; Lu, Hanzhang; Filbey, Francesca M.; Pinkham, Amy E.; McAdams, Carrie J.; Adinoff, Bryon; Daliparthi, Vamsi; Cao, Yan

    2014-01-01

    Phase-Contrast MRI (PC-MRI) is a noninvasive technique to measure blood flow. In particular, global but highly quantitative cerebral blood flow (CBF) measurement using PC-MRI complements several other CBF mapping methods such as arterial spin labeling and dynamic susceptibility contrast MRI by providing a calibration factor. The ability to estimate blood supply in physiological units also lays a foundation for assessment of brain metabolic rate. However, a major obstacle before wider applications of this method is that the slice positioning of the scan, ideally placed perpendicular to the feeding arteries, requires considerable expertise and can present a burden to the operator. In the present work, we proposed that the majority of PC-MRI scans can be positioned using an automatic algorithm, leaving only a small fraction of arteries requiring manual positioning. We implemented and evaluated an algorithm for this purpose based on feature extraction of a survey angiogram, which is of minimal operator dependence. In a comparative test-retest study with 7 subjects, the blood flow measurement using this algorithm showed an inter-session coefficient of variation (CoV) of . The Bland-Altman method showed that the automatic method differs from the manual method by between and , for of the CBF measurements. This is comparable to the variance in CBF measurement using manually-positioned PC MRI alone. In a further application of this algorithm to 157 consecutive subjects from typical clinical cohorts, the algorithm provided successful positioning in 89.7% of the arteries. In 79.6% of the subjects, all four arteries could be planned using the algorithm. Chi-square tests of independence showed that the success rate was not dependent on the age or gender, but the patients showed a trend of lower success rate (p = 0.14) compared to healthy controls. In conclusion, this automatic positioning algorithm could improve the application of PC-MRI in CBF quantification. PMID:24787742

  7. Blood circulatory system for noninvasive diagnostics

    NASA Astrophysics Data System (ADS)

    Fricke, D.; Kraitl, J.; Ewald, H.

    2013-02-01

    Based on the human circulatory system, an artificial blood circulatory system was developed to allow the controlled variation of the following blood parameters: total hemoglobin concentration (ctHb), oxyhemoglobin (O2Hb) methemoglobin (MetHb) and carboxyhemoglobin (COHb). The optical properties of the blood were observed by online spectrometer measurements. The purpose of this was to observe and quantify the absorption, transmission and scattering properties of human whole blood in the wavelength range of 400 to 1700 nm. All the non-invasive measurements of the whole blood transmission-spectra were compared with sample results obtained by a Blood Gas Analyzer (BGA) to validate the results. For all measurements, donor erythrocyte concentrates were used. The concentration of hemoglobin was changed by adding fixed amounts of blood plasma to the erythrocyte concentrate. Oxygen saturation and COHb were adjusted by a continuous flow of N2, N2-CO and compressed air through a hollow fibre membrane oxygenator. Different methemoglobin concentrations were adjusted by using natrium nitrite. The blood temperature was kept constant at 37 °C via a tube heating mechanism, with a separate circulation of water passing through the membrane Oxygenator. The Temperature and pressure of the system were automatically controlled and monitored. The model was also used to test new non-invasive measurement systems, and for this reason special cuvettes were designed to imitate human tissue and generate plethysmographical signals. In the future, the blood circulatory system has the potential to be used for testing, validating and also to calibrate newly developed optical prototype devices. It can also be used to further investigate blood components of interest.

  8. Evaluation of three automatic oxygen therapy control algorithms on ventilated low birth weight neonates.

    PubMed

    Morozoff, Edmund P; Smyth, John A

    2009-01-01

    Neonates with under developed lungs often require oxygen therapy. During the course of oxygen therapy, elevated levels of blood oxygenation, hyperoxemia, must be avoided or the risk of chronic lung disease or retinal damage is increased. Low levels of blood oxygen, hypoxemia, may lead to permanent brain tissue damage and, in some cases, mortality. A closed loop controller that automatically administers oxygen therapy using 3 algorithms - state machine, adaptive model, and proportional integral derivative (PID) - is applied to 7 ventilated low birth weight neonates and compared to manual oxygen therapy. All 3 automatic control algorithms demonstrated their ability to improve manual oxygen therapy by increasing periods of normoxemia and reducing the need for manual FiO(2) adjustments. Of the three control algorithms, the adaptive model showed the best performance with 0.25 manual adjustments per hour and 73% time spent within target +/- 3% SpO(2).

  9. Correlation Between Maternal and Fetal Insulin Resistance in Pregnant Women with Gestational Diabetes Mellitus.

    PubMed

    Wang, Xuqin; Yang, Ting; Miao, Jingkun; Liu, Huan; Wu, Kaifeng; Guo, Jing; Chen, Jie; Li, Tingyu

    2018-06-01

    Offspring of mothers with gestational diabetes mellitus (GDM) are far more likely to develop type 2 diabetes. The aim of this study was to investigate the effect of the insulin metabolism of pregnant women with GDM in late pregnancy on the insulin metabolism of the fetuses and their correlation. This study enrolled 55 pregnant women with GDM and 87 control subjects. Fasting venous blood samples and umbilical venous blood samples (reflecting fetal metabolism) were collected from the study subjects. All blood samples were used to evaluate the blood glucose and insulin concentrations. The blood glucose and insulin concentrations were measured using an automatic biochemical analyser and radioimmunoassay, respectively. The homeostasis model assessment (HOMA) was performed to assess the insulin resistance of mother and fetus. 1. The fasting blood glucose, fasting insulin, and HOMA-IR of pregnant women in the late pregnancy GDM group were all significantly higher than those in the control group (fasting blood glucose: 4.70 ± 0.11 vs. 4.11 ± 0.05 mmol/L, p < 0.001; fasting insulin: 44.1 ± 6.76 vs. 25.1 ± 3.58 µU/mL, p = 0.013; HOMA-IR: 8.92 ± 1.25 vs. 5.39 ± 0.83, p = 0.012); 2. The results of logistic regression analyses showed that maternal age, pre-pregnancy body mass index (BMI), and family history of diabetes were high-risk factors for the development of GDM in pregnant women. 3. The insulin level and HOMA-IR in the umbilical venous blood of the late pregnancy GDM group were both significantly higher than those in the control group (insulin: 10.1 ± 1.41 vs. 6.38 ± 0.49 µU/mL, p = 0.035; HOMA-IR: 1.60 ± 0.22 vs. 1.07 ± 0.08, p = 0.006). 4. The umbilical venous blood HOMA-IR in the GDM group positively correlated with the maternal HOMA-IR and fasting insulin level. The neonatal ponderal index (PI) in the GDM group positively correlated with the umbilical venous blood HOMA-IR and insulin level. The HOMA-IR was significantly higher in the late pregnancy GDM women and their fetuses than in the control group. In addition, fetal HOMA-IR positively correlated to maternal HOMA-IR in late pregnancy GDM women.

  10. Feasibility of a novel one-stop ISET device to capture CTCs and its clinical application

    PubMed Central

    Zheng, Liang; Zhi, Xuan; Cheng, Boran; Chen, Yuanyuan; Zhang, Chunxiao; Shi, Dongdong; Song, Haibin; Cai, Congli; Zhou, Pengfei; Xiong, Bin

    2017-01-01

    Introduction Circulating tumor cells (CTCs) play a crucial role in cancer metastasis. In this study, we introduced a novel isolation method by size of epithelial tumor cells (ISET) device with automatic isolation and staining procedure, named one-stop ISET (osISET) and validated its feasibility to capture CTCs from cancer patients. Moreover, we aim to investigate the correlation between clinicopathologic features and CTCs in colorectal cancer (CRC) in order to explore its clinical application. Results The capture efficiency ranged from 80.3% to 88% with tumor cells spiked into medium while 67% to 78.3% with tumor cells spiked into healthy donors’ blood. In detection blood samples of 72 CRC patients, CTCs and clusters of circulating tumor cells (CTC-clusters) were detected with a positive rate of 52.8% (38/72) and 18.1% (13/72) respectively. Moreover, CTC positive rate was associated with factors of lymphatic or venous invasion, tumor depth, lymph node metastasis and TNM stage in CRC patients (p < 0.01). Lymphocyte count and neutrophil to lymphocyte ratio (NLR) were significantly different between CTC positive and negative groups (p < 0.01). Materials and Methods The capture efficiency of the device was tested by spiking cancer cells (MCF-7, A549, SW480, Hela) into medium or blood samples of healthy donors. Blood samples of 72 CRC patients were detected by osISET device. The clinicopathologic characteristics of 72 CRC patients were collected and the association with CTC positive rate or CTC count were analyzed. Conclusions Our osISET device was feasible to capture and identify CTCs and CTC-clusters from cancer patients. In addition, our device holds a potential for application in cancer management. PMID:27935872

  11. Comparison of an automatic analysis and a manual analysis of conjunctival microcirculation in a sheep model of haemorrhagic shock.

    PubMed

    Arnemann, Philip-Helge; Hessler, Michael; Kampmeier, Tim; Morelli, Andrea; Van Aken, Hugo Karel; Westphal, Martin; Rehberg, Sebastian; Ertmer, Christian

    2016-12-01

    Life-threatening diseases of critically ill patients are known to derange microcirculation. Automatic analysis of microcirculation would provide a bedside diagnostic tool for microcirculatory disorders and allow immediate therapeutic decisions based upon microcirculation analysis. After induction of general anaesthesia and instrumentation for haemodynamic monitoring, haemorrhagic shock was induced in ten female sheep by stepwise blood withdrawal of 3 × 10 mL per kilogram body weight. Before and after the induction of haemorrhagic shock, haemodynamic variables, samples for blood gas analysis, and videos of conjunctival microcirculation were obtained by incident dark field illumination microscopy. Microcirculatory videos were analysed (1) manually with AVA software version 3.2 by an experienced user and (2) automatically by AVA software version 4.2 for total vessel density (TVD), perfused vessel density (PVD) and proportion of perfused vessels (PPV). Correlation between the two analysis methods was examined by intraclass correlation coefficient and Bland-Altman analysis. The induction of haemorrhagic shock decreased the mean arterial pressure (from 87 ± 11 to 40 ± 7 mmHg; p < 0.001); stroke volume index (from 38 ± 14 to 20 ± 5 ml·m -2 ; p = 0.001) and cardiac index (from 2.9 ± 0.9 to 1.8 ± 0.5 L·min -1 ·m -2 ; p < 0.001) and increased the heart rate (from 72 ± 9 to 87 ± 11 bpm; p < 0.001) and lactate concentration (from 0.9 ± 0.3 to 2.0 ± 0.6 mmol·L -1 ; p = 0.001). Manual analysis showed no change in TVD (17.8 ± 4.2 to 17.8 ± 3.8 mm*mm -2 ; p = 0.993), whereas PVD (from 15.6 ± 4.6 to 11.5 ± 6.5 mm*mm -2 ; p = 0.041) and PPV (from 85.9 ± 11.8 to 62.7 ± 29.6%; p = 0.017) decreased significantly. Automatic analysis was not able to identify these changes. Correlation analysis showed a poor correlation between the analysis methods and a wide spread of values in Bland-Altman analysis. As characteristic changes in microcirculation during ovine haemorrhagic shock were not detected by automatic analysis and correlation between automatic and manual analyses (current gold standard) was poor, the use of the investigated software for automatic analysis of microcirculation cannot be recommended in its current version at least in the investigated model. Further improvements in automatic vessel detection are needed before its routine use.

  12. Use of home blood-pressure monitoring in the detection, treatment and surveillance of hypertension.

    PubMed

    Manning, Gillian; Donnelly, Richard

    2005-11-01

    Use of home blood-pressure monitoring is increasing but the technique and the equipment have limitations. We provide an overview of recent evidence in this rapidly evolving field. Home blood-pressure monitoring is an acceptable method for screening patients for hypertension. There is increasing evidence supporting the predictive power of home blood pressure for stroke risk even in the general population. The identification of white-coat and masked hypertension remains an important role for home blood-pressure monitoring. Unvalidated equipment and poor patient technique are major concerns. The purchase of devices needs to be linked to a simple patient-education programme, which is perhaps an opportunity for collaboration between healthcare providers and commercial companies. Devices that store the blood-pressure measurements in the memory are preferred to ensure accuracy of reporting. Data-transmission systems providing automatic storage, transmission and reporting of blood pressure, direct involvement of the patient and potentially a reduced number of hospital/general practitioner visits, offer significant advantages. To reduce patient anxiety, overuse of home blood-pressure monitoring should be avoided but there is the potential for self-modification of treatment, subject to certain safeguards. Self-monitoring of blood pressure is developing rapidly, linked to increasing awareness of the impact of reducing high blood pressure on public health and the marketing/advertising strategies used to sell automatic devices. Home blood-pressure monitoring has a role in the detection and management of blood pressure, but not at the expense of careful blood-pressure measurement in the office and adherence to national guidelines.

  13. Advanced statistical analysis of Raman spectroscopic data for the identification of body fluid traces: semen and blood mixtures.

    PubMed

    Sikirzhytski, Vitali; Sikirzhytskaya, Aliaksandra; Lednev, Igor K

    2012-10-10

    Conventional confirmatory biochemical tests used in the forensic analysis of body fluid traces found at a crime scene are destructive and not universal. Recently, we reported on the application of near-infrared (NIR) Raman microspectroscopy for non-destructive confirmatory identification of pure blood, saliva, semen, vaginal fluid and sweat. Here we expand the method to include dry mixtures of semen and blood. A classification algorithm was developed for differentiating pure body fluids and their mixtures. The classification methodology is based on an effective combination of Support Vector Machine (SVM) regression (data selection) and SVM Discriminant Analysis of preprocessed experimental Raman spectra collected using an automatic mapping of the sample. This extensive cross-validation of the obtained results demonstrated that the detection limit of the minor contributor is as low as a few percent. The developed methodology can be further expanded to any binary mixture of complex solutions, including but not limited to mixtures of other body fluids. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  14. Statistical Methods in Assembly Quality Management of Multi-Element Products on Automatic Rotor Lines

    NASA Astrophysics Data System (ADS)

    Pries, V. V.; Proskuriakov, N. E.

    2018-04-01

    To control the assembly quality of multi-element mass-produced products on automatic rotor lines, control methods with operational feedback are required. However, due to possible failures in the operation of the devices and systems of automatic rotor line, there is always a real probability of getting defective (incomplete) products into the output process stream. Therefore, a continuous sampling control of the products completeness, based on the use of statistical methods, remains an important element in managing the quality of assembly of multi-element mass products on automatic rotor lines. The feature of continuous sampling control of the multi-element products completeness in the assembly process is its breaking sort, which excludes the possibility of returning component parts after sampling control to the process stream and leads to a decrease in the actual productivity of the assembly equipment. Therefore, the use of statistical procedures for continuous sampling control of the multi-element products completeness when assembled on automatic rotor lines requires the use of such sampling plans that ensure a minimum size of control samples. Comparison of the values of the limit of the average output defect level for the continuous sampling plan (CSP) and for the automated continuous sampling plan (ACSP) shows the possibility of providing lower limit values for the average output defects level using the ACSP-1. Also, the average sample size when using the ACSP-1 plan is less than when using the CSP-1 plan. Thus, the application of statistical methods in the assembly quality management of multi-element products on automatic rotor lines, involving the use of proposed plans and methods for continuous selective control, will allow to automating sampling control procedures and the required level of quality of assembled products while minimizing sample size.

  15. Leukocyte adhesion: High-speed cells with ABS.

    PubMed

    van der Merwe, P A

    1999-06-03

    In order to decide where to exit blood vessels and enter tissues, leukocytes roll along endothelial surfaces. Recent studies suggest that an 'automatic braking system' (ABS), involving selectin cell-adhesion molecules, enables leukocytes to roll at a fairly constant velocity despite large variations in blood flow rate.

  16. Fully automatic region of interest selection in glomerular filtration rate estimation from 99mTc-DTPA renogram.

    PubMed

    Lin, Kun-Ju; Huang, Jia-Yann; Chen, Yung-Sheng

    2011-12-01

    Glomerular filtration rate (GFR) is a common accepted standard estimation of renal function. Gamma camera-based methods for estimating renal uptake of (99m)Tc-diethylenetriaminepentaacetic acid (DTPA) without blood or urine sampling have been widely used. Of these, the method introduced by Gates has been the most common method. Currently, most of gamma cameras are equipped with a commercial program for GFR determination, a semi-quantitative analysis by manually drawing region of interest (ROI) over each kidney. Then, the GFR value can be computed from the scintigraphic determination of (99m)Tc-DTPA uptake within the kidney automatically. Delineating the kidney area is difficult when applying a fixed threshold value. Moreover, hand-drawn ROIs are tedious, time consuming, and dependent highly on operator skill. Thus, we developed a fully automatic renal ROI estimation system based on the temporal changes in intensity counts, intensity-pair distribution image contrast enhancement method, adaptive thresholding, and morphological operations that can locate the kidney area and obtain the GFR value from a (99m)Tc-DTPA renogram. To evaluate the performance of the proposed approach, 30 clinical dynamic renograms were introduced. The fully automatic approach failed in one patient with very poor renal function. Four patients had a unilateral kidney, and the others had bilateral kidneys. The automatic contours from the remaining 54 kidneys were compared with the contours of manual drawing. The 54 kidneys were included for area error and boundary error analyses. There was high correlation between two physicians' manual contours and the contours obtained by our approach. For area error analysis, the mean true positive area overlap is 91%, the mean false negative is 13.4%, and the mean false positive is 9.3%. The boundary error is 1.6 pixels. The GFR calculated using this automatic computer-aided approach is reproducible and may be applied to help nuclear medicine physicians in clinical practice.

  17. Blood-Banking Techniques for Plateletpheresis in Swine

    DTIC Science & Technology

    2014-05-01

    automatically calculates the blood volume for that patient according to an internal formula . However, to circumvent the human-based algorithm, for a 60-kg...blood volume (µL) in the percentage recovery formula given earlier. The maximal recovery percent- age was calculated by setting the 3-min results to 100...Control Resuscitation Department, the Veterinary Support Department, and the Laboratory Support Department for their expert technical assistance

  18. Performance of the Colson MAM BP 3AA1-2 automatic blood pressure monitor according to the European Society of Hypertension validation protocol.

    PubMed

    Pereira, Telmo; Maldonado, João

    2005-11-01

    To evaluate the performance of the Colson MAM BP 3AA1-2 oscillometric automatic blood pressure monitor according to the validation protocol of the European Society of Hypertension, testing its suitability for self-measurement of blood pressure. The performance of the device was assessed in relation to various clinical variables, including age, gender, body mass index, arm circumference and arterial stiffness. 33 subjects (15 men and 18 women), with a mean age of 47 +/- 10 years, were studied according to the procedures laid down in the European Society of Hypertension validation protocol. Sequential same-arm blood pressure measurements were made, alternating between a mercury standard and the automatic device. The differences among the test-control measurements were assessed and divided into categorization zones of 5, 10 and 15 mmHg discrepancy. Aortic pulse wave velocity was assessed in all subjects with a Complior device (Colson, Paris). The Colson MAM BP 3AA1-2 passed all three phases of the protocol for both systolic and diastolic blood pressure. The mean differences between the test and control measurements were -1.0 +/- 5.0 mmHg for systolic blood pressure and -1.1 +/- 4.1 mmHg for diastolic blood pressure. Both standard deviations are well below the 8 mmHg limit proposed by the Association for the Advancement of Medical Instrumentation. The predictive value of various clinical variables for the discrepancies was assessed by a regression model analysis, with no variable being found that independently undermined the performance of the monitor. In another regression analysis, we found a similar relation between test and control blood pressures and aortic pulse wave velocity, a widely recognized and validated index of target organ damage. These data show that the Colson MAM BP 3AA1-2 satisfies the quality requirements proposed by the European Society of Hypertension, demonstrating its suitability for inclusion in integrated programs of clinical surveillance based on self-measurement of blood pressure. The uniformity of its performance over a wide spectrum of clinical characteristics and the relation found with pulse wave velocity further reinforce its clinical validity.

  19. A new blood vessel extraction technique using edge enhancement and object classification.

    PubMed

    Badsha, Shahriar; Reza, Ahmed Wasif; Tan, Kim Geok; Dimyati, Kaharudin

    2013-12-01

    Diabetic retinopathy (DR) is increasing progressively pushing the demand of automatic extraction and classification of severity of diseases. Blood vessel extraction from the fundus image is a vital and challenging task. Therefore, this paper presents a new, computationally simple, and automatic method to extract the retinal blood vessel. The proposed method comprises several basic image processing techniques, namely edge enhancement by standard template, noise removal, thresholding, morphological operation, and object classification. The proposed method has been tested on a set of retinal images. The retinal images were collected from the DRIVE database and we have employed robust performance analysis to evaluate the accuracy. The results obtained from this study reveal that the proposed method offers an average accuracy of about 97 %, sensitivity of 99 %, specificity of 86 %, and predictive value of 98 %, which is superior to various well-known techniques.

  20. Automatic instrument for chemical processing to detect microorganism in biological samples by measuring light reactions

    NASA Technical Reports Server (NTRS)

    Kelbaugh, B. N.; Picciolo, G. L.; Chappelle, E. W.; Colburn, M. E. (Inventor)

    1973-01-01

    An automated apparatus is reported for sequentially assaying urine samples for the presence of bacterial adenosine triphosphate (ATP) that comprises a rotary table which carries a plurality of sample containing vials and automatically dispenses fluid reagents into the vials preparatory to injecting a light producing luciferase-luciferin mixture into the samples. The device automatically measures the light produced in each urine sample by a bioluminescence reaction of the free bacterial adenosine triphosphate with the luciferase-luciferin mixture. The light measured is proportional to the concentration of bacterial adenosine triphosphate which, in turn, is proportional to the number of bacteria present in the respective urine sample.

  1. Automatic Emboli Detection System for the Artificial Heart

    NASA Astrophysics Data System (ADS)

    Steifer, T.; Lewandowski, M.; Karwat, P.; Gawlikowski, M.

    In spite of the progress in material engineering and ventricular assist devices construction, thromboembolism remains the most crucial problem in mechanical heart supporting systems. Therefore, the ability to monitor the patient's blood for clot formation should be considered an important factor in development of heart supporting systems. The well-known methods for automatic embolus detection are based on the monitoring of the ultrasound Doppler signal. A working system utilizing ultrasound Doppler is being developed for the purpose of flow estimation and emboli detection in the clinical artificial heart ReligaHeart EXT. Thesystem will be based on the existing dual channel multi-gate Doppler device with RF digital processing. A specially developed clamp-on cannula probe, equipped with 2 - 4 MHz piezoceramic transducers, enables easy system setup. We present the issuesrelated to the development of automatic emboli detection via Doppler measurements. We consider several algorithms for the flow estimation and emboli detection. We discuss their efficiency and confront them with the requirements of our experimental setup. Theoretical considerations are then met with preliminary experimental findings from a) flow studies with blood mimicking fluid and b) in-vitro flow studies with animal blood. Finally, we discuss some more methodological issues - we consider several possible approaches to the problem of verification of the accuracy of the detection system.

  2. Comparison of the efficiency between two sampling plans for aflatoxins analysis in maize

    PubMed Central

    Mallmann, Adriano Olnei; Marchioro, Alexandro; Oliveira, Maurício Schneider; Rauber, Ricardo Hummes; Dilkin, Paulo; Mallmann, Carlos Augusto

    2014-01-01

    Variance and performance of two sampling plans for aflatoxins quantification in maize were evaluated. Eight lots of maize were sampled using two plans: manual, using sampling spear for kernels; and automatic, using a continuous flow to collect milled maize. Total variance and sampling, preparation, and analysis variance were determined and compared between plans through multifactor analysis of variance. Four theoretical distribution models were used to compare aflatoxins quantification distributions in eight maize lots. The acceptance and rejection probabilities for a lot under certain aflatoxin concentration were determined using variance and the information on the selected distribution model to build the operational characteristic curves (OC). Sampling and total variance were lower at the automatic plan. The OC curve from the automatic plan reduced both consumer and producer risks in comparison to the manual plan. The automatic plan is more efficient than the manual one because it expresses more accurately the real aflatoxin contamination in maize. PMID:24948911

  3. Monitoring of left ventricular ejection fraction with a miniature, nonimaging nuclear detector: accuracy and reliability over time with special reference to blood labeling.

    PubMed

    Lindhardt, T B; Hesse, B; Gadsbøll, N

    1997-01-01

    The purpose of this study was to determine the accuracy of determinations of left ventricular ejection fraction (LVEF) by a nonimaging miniature nuclear detector system (Cardioscint) and to evaluate the feasibility of long-term LVEF monitoring in patients admitted to the coronary care unit, with special reference to the blood-labeling technique. Cardioscint LVEF values were compared with measurements of LVEF by conventional gamma camera radionuclide ventriculography in 33 patients with a wide range of LVEF values. In 21 of the 33 patients, long-term monitoring was carried out for 1 to 4 hours (mean 186 minutes), with three different kits: one for in vivo and two for in vitro red blood cell labeling. The stability of the labeling was assessed by determination of the activity of blood samples taken during the first 24 hours after blood labeling. The agreement between Cardioscint LVEF and gamma camera LVEF was good with automatic background correction (r = 0.82; regression equation y = 1.04x + 3.88) but poor with manual background correction (r = 0.50; y = 0.88x - 0.55). The agreement was highest in patients without wall motion abnormalities. The long-term monitoring showed no difference between morning and afternoon Cardioscint LVEF values. Short-lasting fluctuations in LVEFs greater than 10 EF units were observed in the majority of the patients. After 24 hours, the mean reduction in the physical decay-corrected count rate of the blood samples was most pronounced for the two in vitro blood-labeling kits (57% +/- 9% and 41% +/- 3%) and less for the in vivo blood-labeling kit (32% +/- 26%). This "biologic decay" had a marked influence on the Cardioscint monitoring results, demanding frequent background correction. A fairly accurate estimate of LVEF can be obtained with the nonimaging Cardioscint system, and continuous bedside LVEF monitoring can proceed for hours with little inconvenience to the patients. Instability of the red blood cell labeling during long-term monitoring necessitates frequent background correction.

  4. Automatic detection of blood versus non-blood regions on intravascular ultrasound (IVUS) images using wavelet packet signatures

    NASA Astrophysics Data System (ADS)

    Katouzian, Amin; Baseri, Babak; Konofagou, Elisa E.; Laine, Andrew F.

    2008-03-01

    Intravascular ultrasound (IVUS) has been proven a reliable imaging modality that is widely employed in cardiac interventional procedures. It can provide morphologic as well as pathologic information on the occluded plaques in the coronary arteries. In this paper, we present a new technique using wavelet packet analysis that differentiates between blood and non-blood regions on the IVUS images. We utilized the multi-channel texture segmentation algorithm based on the discrete wavelet packet frames (DWPF). A k-mean clustering algorithm was deployed to partition the extracted textural features into blood and non-blood in an unsupervised fashion. Finally, the geometric and statistical information of the segmented regions was used to estimate the closest set of pixels to the lumen border and a spline curve was fitted to the set. The presented algorithm may be helpful in delineating the lumen border automatically and more reliably prior to the process of plaque characterization, especially with 40 MHz transducers, where appearance of the red blood cells renders the border detection more challenging, even manually. Experimental results are shown and they are quantitatively compared with manually traced borders by an expert. It is concluded that our two dimensional (2-D) algorithm, which is independent of the cardiac and catheter motions performs well in both in-vivo and in-vitro cases.

  5. An automatic device for detection and classification of malaria parasite species in thick blood film.

    PubMed

    Kaewkamnerd, Saowaluck; Uthaipibull, Chairat; Intarapanich, Apichart; Pannarut, Montri; Chaotheing, Sastra; Tongsima, Sissades

    2012-01-01

    Current malaria diagnosis relies primarily on microscopic examination of Giemsa-stained thick and thin blood films. This method requires vigorously trained technicians to efficiently detect and classify the malaria parasite species such as Plasmodium falciparum (Pf) and Plasmodium vivax (Pv) for an appropriate drug administration. However, accurate classification of parasite species is difficult to achieve because of inherent technical limitations and human inconsistency. To improve performance of malaria parasite classification, many researchers have proposed automated malaria detection devices using digital image analysis. These image processing tools, however, focus on detection of parasites on thin blood films, which may not detect the existence of parasites due to the parasite scarcity on the thin blood film. The problem is aggravated with low parasitemia condition. Automated detection and classification of parasites on thick blood films, which contain more numbers of parasite per detection area, would address the previous limitation. The prototype of an automatic malaria parasite identification system is equipped with mountable motorized units for controlling the movements of objective lens and microscope stage. This unit was tested for its precision to move objective lens (vertical movement, z-axis) and microscope stage (in x- and y-horizontal movements). The average precision of x-, y- and z-axes movements were 71.481 ± 7.266 μm, 40.009 ± 0.000 μm, and 7.540 ± 0.889 nm, respectively. Classification of parasites on 60 Giemsa-stained thick blood films (40 blood films containing infected red blood cells and 20 control blood films of normal red blood cells) was tested using the image analysis module. By comparing our results with the ones verified by trained malaria microscopists, the prototype detected parasite-positive and parasite-negative blood films at the rate of 95% and 68.5% accuracy, respectively. For classification performance, the thick blood films with Pv parasite was correctly classified with the success rate of 75% while the accuracy of Pf classification was 90%. This work presents an automatic device for both detection and classification of malaria parasite species on thick blood film. The system is based on digital image analysis and featured with motorized stage units, designed to easily be mounted on most conventional light microscopes used in the endemic areas. The constructed motorized module could control the movements of objective lens and microscope stage at high precision for effective acquisition of quality images for analysis. The analysis program could accurately classify parasite species, into Pf or Pv, based on distribution of chromatin size.

  6. Ultramicro-fluorometric assay for the diagnosis of Gaucher disease in dried blood spots on filter paper.

    PubMed

    Herrera, D; Monaga, M; Campos, D; Pampín, Y; González, E C; Lavaut, K

    2013-01-01

    Gaucher disease (GD) is a lysosomal storage disorder characterized by a deficiency of the lysosomal acid β-D-glucosidase (GBA). The aim of this study was to develop an ultramicro-fluorometric assay based on the method of Chamoles et al. for determining GBA activity in dried blood spots on filter paper (DBS). The assay used 3-mm diameter blood spot and 8 mmol/l of 4-methylumbelliferyl-β-D-glucoside as enzymatic substrate. The reaction occurred in plates incubated at 37°C for 20 hours and the enzyme activity was expressed in μmol hydrolysed substrate/l blood/h. The fluorescence of the enzyme product was automatically measured in a fluorometer-photometer reader (SUMA Technology). The intra and inter-assay coefficients of variation were lower than 9 and 12%, respectively, and the recovery range was 97-109%.Three patients with GD were correctly diagnosed using the ultramicroassay. Healthy newborn DBS samples (n = 3003) from the National Neonatal Screening Program were analyzed, and the mean GBA activity was 5.7 μmol/l blood/h. Our assay showed high Pearson (n = 26; r = 0.99) and concordance correlations (ρc = 0.99) with the traditional method described by Chamoles et al. The analytical performance characteristics of our ultramicro-fluorometric assay suggest that it can be used in the diagnosis of GD in newborns and adults.

  7. Some Thermophysical Properties of Blood Components and Coolants for Frozen Blood Shipping Containers

    DTIC Science & Technology

    1989-09-01

    SP number by sending a DP reading. Subroutine : AutoControl Automatic control to set temperature. : Autodisplay Get ilL Thermocouple readings and...RETURN 133 AutoControl : Auto control Mode ON TIMER(ReportTime) GOSUB Autodisplay Update Screen in constant interval TIMER ON WHILE Success a 0 Turn off

  8. Closing the Loop on Critical Care Life Support for Military en route Care Environments

    DTIC Science & Technology

    2004-09-01

    pig’s blood volume. Resuscitation was then initiated by turning on the autocontrol software which ran on an external computer which was receiving mean...that initiated the occlusion alarm. When the occlusion was released, the autocontrol resumed automatically and restored the blood pressure once again

  9. Computer-assisted liver graft steatosis assessment via learning-based texture analysis.

    PubMed

    Moccia, Sara; Mattos, Leonardo S; Patrini, Ilaria; Ruperti, Michela; Poté, Nicolas; Dondero, Federica; Cauchy, François; Sepulveda, Ailton; Soubrane, Olivier; De Momi, Elena; Diaspro, Alberto; Cesaretti, Manuela

    2018-05-23

    Fast and accurate graft hepatic steatosis (HS) assessment is of primary importance for lowering liver dysfunction risks after transplantation. Histopathological analysis of biopsied liver is the gold standard for assessing HS, despite being invasive and time consuming. Due to the short time availability between liver procurement and transplantation, surgeons perform HS assessment through clinical evaluation (medical history, blood tests) and liver texture visual analysis. Despite visual analysis being recognized as challenging in the clinical literature, few efforts have been invested to develop computer-assisted solutions for HS assessment. The objective of this paper is to investigate the automatic analysis of liver texture with machine learning algorithms to automate the HS assessment process and offer support for the surgeon decision process. Forty RGB images of forty different donors were analyzed. The images were captured with an RGB smartphone camera in the operating room (OR). Twenty images refer to livers that were accepted and 20 to discarded livers. Fifteen randomly selected liver patches were extracted from each image. Patch size was [Formula: see text]. This way, a balanced dataset of 600 patches was obtained. Intensity-based features (INT), histogram of local binary pattern ([Formula: see text]), and gray-level co-occurrence matrix ([Formula: see text]) were investigated. Blood-sample features (Blo) were included in the analysis, too. Supervised and semisupervised learning approaches were investigated for feature classification. The leave-one-patient-out cross-validation was performed to estimate the classification performance. With the best-performing feature set ([Formula: see text]) and semisupervised learning, the achieved classification sensitivity, specificity, and accuracy were 95, 81, and 88%, respectively. This research represents the first attempt to use machine learning and automatic texture analysis of RGB images from ubiquitous smartphone cameras for the task of graft HS assessment. The results suggest that is a promising strategy to develop a fully automatic solution to assist surgeons in HS assessment inside the OR.

  10. Automatic white blood cell classification using pre-trained deep learning models: ResNet and Inception

    NASA Astrophysics Data System (ADS)

    Habibzadeh, Mehdi; Jannesari, Mahboobeh; Rezaei, Zahra; Baharvand, Hossein; Totonchi, Mehdi

    2018-04-01

    This works gives an account of evaluation of white blood cell differential counts via computer aided diagnosis (CAD) system and hematology rules. Leukocytes, also called white blood cells (WBCs) play main role of the immune system. Leukocyte is responsible for phagocytosis and immunity and therefore in defense against infection involving the fatal diseases incidence and mortality related issues. Admittedly, microscopic examination of blood samples is a time consuming, expensive and error-prone task. A manual diagnosis would search for specific Leukocytes and number abnormalities in the blood slides while complete blood count (CBC) examination is performed. Complications may arise from the large number of varying samples including different types of Leukocytes, related sub-types and concentration in blood, which makes the analysis prone to human error. This process can be automated by computerized techniques which are more reliable and economical. In essence, we seek to determine a fast, accurate mechanism for classification and gather information about distribution of white blood evidences which may help to diagnose the degree of any abnormalities during CBC test. In this work, we consider the problem of pre-processing and supervised classification of white blood cells into their four primary types including Neutrophils, Eosinophils, Lymphocytes, and Monocytes using a consecutive proposed deep learning framework. For first step, this research proposes three consecutive pre-processing calculations namely are color distortion; bounding box distortion (crop) and image flipping mirroring. In second phase, white blood cell recognition performed with hierarchy topological feature extraction using Inception and ResNet architectures. Finally, the results obtained from the preliminary analysis of cell classification with (11200) training samples and 1244 white blood cells evaluation data set are presented in confusion matrices and interpreted using accuracy rate, and false positive with the classification framework being validated with experiments conducted on poor quality blood images sized 320 × 240 pixels. The deferential outcomes in the challenging cell detection task, as shown in result section, indicate that there is a significant achievement in using Inception and ResNet architecture with proposed settings. Our framework detects on average 100% of the four main white blood cell types using ResNet V1 50 while also alternative promising result with 99.84% and 99.46% accuracy rate obtained with ResNet V1 152 and ResNet 101, respectively with 3000 epochs and fine-tuning all layers. Further statistical confusion matrix tests revealed that this work achieved 1, 0.9979, 0.9989 sensitivity values when area under the curve (AUC) scores above 1, 0.9992, 0.9833 on three proposed techniques. In addition, current work shows negligible and small false negative 0, 2, 1 and substantial false positive with 0, 0, 5 values in Leukocytes detection.

  11. Laparoscopic management of interstitial pregnancy with automatic stapler

    PubMed Central

    Ahsan Akhtar, Muhammad; Izzat, Feras; Keay, Stephen D

    2012-01-01

    A 36-year-old woman was referred by general practitioner to the early pregnancy unit with pelvic pain in her seventh week of pregnancy. She had a transvaginal ultrasound. Unruptured live twin tubal ectopic pregnancy was diagnosed on. Diagnostic laparoscopy revealed an unruptured left interstitial ectopic pregnancy. The interstitial tubal pregnancy was removed by laparoscopic automatic stapler with minimal blood loss. The patient had an uneventful recovery to health. PMID:23093504

  12. Automatic non-proliferative diabetic retinopathy screening system based on color fundus image.

    PubMed

    Xiao, Zhitao; Zhang, Xinpeng; Geng, Lei; Zhang, Fang; Wu, Jun; Tong, Jun; Ogunbona, Philip O; Shan, Chunyan

    2017-10-26

    Non-proliferative diabetic retinopathy is the early stage of diabetic retinopathy. Automatic detection of non-proliferative diabetic retinopathy is significant for clinical diagnosis, early screening and course progression of patients. This paper introduces the design and implementation of an automatic system for screening non-proliferative diabetic retinopathy based on color fundus images. Firstly, the fundus structures, including blood vessels, optic disc and macula, are extracted and located, respectively. In particular, a new optic disc localization method using parabolic fitting is proposed based on the physiological structure characteristics of optic disc and blood vessels. Then, early lesions, such as microaneurysms, hemorrhages and hard exudates, are detected based on their respective characteristics. An equivalent optical model simulating human eyes is designed based on the anatomical structure of retina. Main structures and early lesions are reconstructed in the 3D space for better visualization. Finally, the severity of each image is evaluated based on the international criteria of diabetic retinopathy. The system has been tested on public databases and images from hospitals. Experimental results demonstrate that the proposed system achieves high accuracy for main structures and early lesions detection. The results of severity classification for non-proliferative diabetic retinopathy are also accurate and suitable. Our system can assist ophthalmologists for clinical diagnosis, automatic screening and course progression of patients.

  13. Development of blood vessel searching system for HMS

    NASA Astrophysics Data System (ADS)

    Kandani, Hirofumi; Uenoya, Toshiyuki; Uetsuji, Yasutomo; Nakamachi, Eiji

    2008-08-01

    In this study, we develop a new 3D miniature blood vessel searching system by using near-infrared LED light, a CMOS camera module with an image processing unit for a health monitoring system (HMS), a drug delivery system (DDS) which requires very high performance for automatic micro blood volume extraction and automatic blood examination. Our objective is to fabricate a highly reliable micro detection system by utilizing image capturing, image processing, and micro blood extraction devices. For the searching system to determine 3D blood vessel location, we employ the stereo method. The stereo method is a common photogrammetric method. It employs the optical path principle to detect 3D location of the disparity between two cameras. The principle for blood vessel visualization is derived from the ratio of hemoglobin's absorption of the near-infrared LED light. To get a high quality blood vessel image, we adopted an LED, with peak a wavelength of 940nm. The LED is set on the dorsal side of the finger and it irradiates the human finger. A blood vessel image is captured by a CMOS camera module, which is set below the palmer side of the finger. 2D blood vessel location can be detected by the luminance distribution of a one pixel line. To examine the accuracy of our detecting system, we carried out experiments using finger phantoms with blood vessel diameters of 0.5, 0.75, 1.0mm, at the depths of 0.5 ~ 2.0 mm from the phantom's surface. The experimental results of the estimated depth obtained by our detecting system shows good agreements with the given depths, and the viability of this system is confirmed.

  14. A simple method for the analysis by MS/MS of underivatized amino acids on dry blood spots from newborn screening.

    PubMed

    Wang, Chunyan; Zhang, Wenyan; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying

    2012-05-01

    The analysis by electrospray-ionization tandem mass spectrometry of amino acids with butyl esterification and isotopically labeled internal standard is routine in newborn screening laboratories worldwide. In the present study, we established a direct analysis method of higher accuracy that uses a non-deuterated internal standard. The automatic sampler and the pump of an LC apparatus were used to inject sample and mobile phase to MS, but no LC column was needed. The dry blood spot (DBS) material was prepared at levels of low, medium and high concentration; the running time was 1 min. In parallel to the new procedure, we applied the established method to analyze nine amino acids on DBS of healthy newborns and phenylketonuria newborns. The newly proposed method of product ion confirmation scan along with multiple reaction monitoring resulted in a very accurate identification of each amino acid. Our innovative protocol had high sensitivity and specificity in the analysis of cases of suspected metabolic diseases.

  15. Automatic multiple applicator electrophoresis

    NASA Technical Reports Server (NTRS)

    Grunbaum, B. W.

    1977-01-01

    Easy-to-use, economical device permits electrophoresis on all known supporting media. System includes automatic multiple-sample applicator, sample holder, and electrophoresis apparatus. System has potential applicability to fields of taxonomy, immunology, and genetics. Apparatus is also used for electrofocusing.

  16. A new method for automatic discontinuity traces sampling on rock mass 3D model

    NASA Astrophysics Data System (ADS)

    Umili, G.; Ferrero, A.; Einstein, H. H.

    2013-02-01

    A new automatic method for discontinuity traces mapping and sampling on a rock mass digital model is described in this work. The implemented procedure allows one to automatically identify discontinuity traces on a Digital Surface Model: traces are detected directly as surface breaklines, by means of maximum and minimum principal curvature values of the vertices that constitute the model surface. Color influence and user errors, that usually characterize the trace mapping on images, are eliminated. Also trace sampling procedures based on circular windows and circular scanlines have been implemented: they are used to infer trace data and to calculate values of mean trace length, expected discontinuity diameter and intensity of rock discontinuities. The method is tested on a case study: results obtained applying the automatic procedure on the DSM of a rock face are compared to those obtained performing a manual sampling on the orthophotograph of the same rock face.

  17. Dried blood spot measurement of pregnancy-associated plasma protein A (PAPP-A) and free β-subunit of human chorionic gonadotropin (β-hCG) from a low-resource setting.

    PubMed

    Browne, J L; Schielen, P C J I; Belmouden, I; Pennings, J L A; Klipstein-Grobusch, K

    2015-06-01

    The objectives of the article is to compare pregnancy-associated plasma protein A (PAPP-A) and free β-subunit of human chorionic gonadotropin (β-hCG) concentrations in dried blood spots (DBSs) with serum of samples obtained from a public hospital in a low-resource setting and to evaluate their stability. Serum and DBS samples were obtained by venipuncture and finger prick from 50 pregnant participants in a cohort study in a public hospital in Accra, Ghana. PAPP-A and β-hCG concentrations from serum and DBS were measured with an AutoDELFIA® (PerkinElmer, PerkinElmer, Turku, Finland) automatic immunoassay. Correlation and Passing-Bablok regression analyses were performed to compare marker levels. High correlation (>0.9) was observed for PAPP-A and β-hCG levels between various sampling techniques. The β-hCG concentration was stable between DBS and serum, PAPP-A concentration consistently lower in DBS. Our findings suggest that β-hCG can be reliably collected from DBS in low-resource tropical settings. The exact conditions of the clinical workflow necessary for reliable PAPP-A measurement in these settings need to be further developed in the future. These findings could have implications for prenatal screening programs feasibility in low-income and middle-income countries, as DBS provides an alternative minimally invasive sampling method, with advantages in sampling technique, stability, logistics, and potential application in low-resource settings. © 2015 John Wiley & Sons, Ltd.

  18. [Application of automatic photography in Schistosoma japonicum miracidium hatching experiments].

    PubMed

    Ming-Li, Zhou; Ai-Ling, Cai; Xue-Feng, Wang

    2016-05-20

    To explore the value of automatic photography in the observation of results of Schistosoma japonicum miracidium hatching experiments. Some fresh S. japonicum eggs were added into cow feces, and the samples of feces were divided into a low infested experimental group and a high infested group (40 samples each group). In addition, there was a negative control group with 40 samples of cow feces without S. japonicum eggs. The conventional nylon bag S. japonicum miracidium hatching experiments were performed. The process was observed with the method of flashlight and magnifying glass combined with automatic video (automatic photography method), and, at the same time, with the naked eye observation method. The results were compared. In the low infested group, the miracidium positive detection rates were 57.5% and 85.0% by the naked eye observation method and automatic photography method, respectively ( χ 2 = 11.723, P < 0.05). In the high infested group, the positive detection rates were 97.5% and 100% by the naked eye observation method and automatic photography method, respectively ( χ 2 = 1.253, P > 0.05). In the two infested groups, the average positive detection rates were 77.5% and 92.5% by the naked eye observation method and automatic photography method, respectively ( χ 2 = 6.894, P < 0.05). The automatic photography can effectively improve the positive detection rate in the S. japonicum miracidium hatching experiments.

  19. Indirect blood pressure and heart rate measured quickly without observer bias using a semi-automatic machine (auto-manometer)--response to isometric exercise in normal healthy males and its modification by beta-adrenoceptor blockade.

    PubMed Central

    Nyberg, G

    1977-01-01

    1 In a double-blind crossover study, six volunteers performed sustained handgrip at 50% of maximal voluntary contraction before and 90 min following oral administration of 0.25 and 100 mg metoprolol tartrate, a beta1 selective adrenoceptor blocking agent. Blood pressure and heart rate were measured with the Auto-Manometer, an electronic semi-automatic device based on the principles of the London School of Hygiene and Tropical Medicine sphygmomanometer. It eliminates observer and digital bias completely, and also records heart rate at the same time as blood pressure is recorded. 2 Resting heart rate fell 15% after 25 mg, 21% after 100 mg and was unchanged after placebo. Systolic blood pressure fell 6% on both doses and was unchanged on placebo. Diastolic pressure did not change with any of the doses. 3 At 1 min of handgrip, heart rate was significantly lower after 25 and 100 mg than before drug or after placebo. There was no difference between the blood pressure levels attained before or after any of the dose levels. The rise of heart rate tended to be somewhat dampened after 100 mg only. The rise in blood pressure was unchanged after any dose compared with before. Images Figure 1 PMID:901695

  20. Efficient collection of peripheral blood stem cells using the Fresenius AS104 in chronic myelocytic leukemia patients with very high numbers of platelets.

    PubMed

    Komatsu, F; Ishida, Y

    1997-04-01

    For chronic myelocytic leukemia patients with very high numbers of platelets, we describe an efficient method for the collection of peripheral blood stem cells (PBSC) using the Fresenius AS104 cell separator. In these patients, it is difficult to collect a sufficient number of PBSC, due to the platelet band interfering with the machine's red cell interface sensor. We, therefore, tried a manual adjustment of the device. The collection phase was set automatically. When the whole blood began to separate into the red cell layer and plasma (plus mononuclear cell) layer, the red cell interface setting of "7:1" was changed to "OFF," and the plasma pump flow rate was controlled manually in order to locate the interface position 1 cm from the outside wall of the centrifuge chamber. After the collection phase, the procedure was returned to the automatic setting. By repeating this procedure, we were able to collect large numbers of PBSC.

  1. Digital holographic microscopy for detection of Trypanosoma cruzi parasites in fresh blood mounts

    NASA Astrophysics Data System (ADS)

    Romero, G. G.; Monaldi, A. C.; Alanís, E. E.

    2012-03-01

    An off-axis holographic microscope, in a transmission mode, calibrated to automatically detect the presence of Trypanosoma cruzi in blood is developed as an alternative diagnosis tool for Chagas disease. Movements of the microorganisms are detected by measuring the phase shift they produce on the transmitted wave front. A thin layer of blood infected by Trypanosoma cruzi parasites is examined in the holographic microscope, the images of the visual field being registered with a CCD camera. Two consecutive holograms of the same visual field are subtracted point by point and a phase contrast image of the resulting hologram is reconstructed by means of the angular spectrum propagation algorithm. This method enables the measurement of phase distributions corresponding to temporal differences between digital holograms in order to detect whether parasites are present or not. Experimental results obtained using this technique show that it is an efficient alternative that can be incorporated successfully as a part of a fully automatic system for detection and counting of this type of microorganisms.

  2. Combining image-derived and venous input functions enables quantification of serotonin-1A receptors with [carbonyl-11C]WAY-100635 independent of arterial sampling.

    PubMed

    Hahn, Andreas; Nics, Lukas; Baldinger, Pia; Ungersböck, Johanna; Dolliner, Peter; Frey, Richard; Birkfellner, Wolfgang; Mitterhauser, Markus; Wadsak, Wolfgang; Karanikas, Georgios; Kasper, Siegfried; Lanzenberger, Rupert

    2012-08-01

    image- derived input functions (IDIFs) represent a promising technique for a simpler and less invasive quantification of PET studies as compared to arterial cannulation. However, a number of limitations complicate the routine use of IDIFs in clinical research protocols and the full substitution of manual arterial samples by venous ones has hardly been evaluated. This study aims for a direct validation of IDIFs and venous data for the quantification of serotonin-1A receptor binding (5-HT(1A)) with [carbonyl-(11)C]WAY-100635 before and after hormone treatment. Fifteen PET measurements with arterial and venous blood sampling were obtained from 10 healthy women, 8 scans before and 7 after eight weeks of hormone replacement therapy. Image-derived input functions were derived automatically from cerebral blood vessels, corrected for partial volume effects and combined with venous manual samples from 10 min onward (IDIF+VIF). Corrections for plasma/whole-blood ratio and metabolites were done separately with arterial and venous samples. 5-HT(1A) receptor quantification was achieved with arterial input functions (AIF) and IDIF+VIF using a two-tissue compartment model. Comparison between arterial and venous manual blood samples yielded excellent reproducibility. Variability (VAR) was less than 10% for whole-blood activity (p>0.4) and below 2% for plasma to whole-blood ratios (p>0.4). Variability was slightly higher for parent fractions (VARmax=24% at 5 min, p<0.05 and VAR<13% after 20 min, p>0.1) but still within previously reported values. IDIFs after partial volume correction had peak values comparable to AIFs (mean difference Δ=-7.6 ± 16.9 kBq/ml, p>0.1), whereas AIFs exhibited a delay (Δ=4 ± 6.4s, p<0.05) and higher peak width (Δ=15.9 ± 5.2s, p<0.001). Linear regression analysis showed strong agreement for 5-HT(1A) binding as obtained with AIF and IDIF+VIF at baseline (R(2)=0.95), after treatment (R(2)=0.93) and when pooling all scans (R(2)=0.93), with slopes and intercepts in the range of 0.97 to 1.07 and -0.05 to 0.16, respectively. In addition to the region of interest analysis, the approach yielded virtually identical results for voxel-wise quantification as compared to the AIF. Despite the fast metabolism of the radioligand, manual arterial blood samples can be substituted by venous ones for parent fractions and plasma to whole-blood ratios. Moreover, the combination of image-derived and venous input functions provides a reliable quantification of 5-HT(1A) receptors. This holds true for 5-HT(1A) binding estimates before and after treatment for both regions of interest-based and voxel-wise modeling. Taken together, the approach provides less invasive receptor quantification by full independence of arterial cannulation. This offers great potential for the routine use in clinical research protocols and encourages further investigation for other radioligands with different kinetic characteristics. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Analysis of different anthropometric indicators in the detection of high blood pressure in school adolescents: a cross-sectional study with 8295 adolescents.

    PubMed

    Christofaro, Diego G D; Farah, Breno Q; Vanderlei, Luiz Carlos M; Delfino, Leandro D; Tebar, William R; Barros, Mauro Virgílio G de; Ritti-Dias, Raphael M

    High blood pressure is strongly associated with obesity in different populations. However, it is unclear whether different anthropometric indicators of obesity can satisfactorily predict high blood pressure in the school setting. This study evaluated the sensitivity and specificity of body mass index, waist circumference, and waist to height ratio in the detection of high blood pressure in adolescents. The sample consisted of 8295 adolescents aged 10-17 years. Weight was measured using a digital scale, height with a stadiometer, and waist circumference using a tape measure. Blood pressure was measured by an automatic blood pressure measuring device. ROC curves were used for the analysis of sensitivity and specificity of the three anthropometric indices in identifying high blood pressure. Binary Logistic Regression was used to assess the association of body mass index, waist circumference, and waist to height ratio with high blood pressure. Low values of sensitivity were observed for body mass index (0.35), waist circumference (0.37), and waist to height ratio (0.31) and high values of specificity for body mass index (0.86), waist circumference (0.82), and waist to height ratio (0.83) in the detection of high blood pressure. An association was observed between adolescents classified with high body mass index (OR=3.57 [95% CI=3.10-4.10]), waist cirumference (OR=3.24 [95% CI=2.83-3.72]), and waist to height ratio (OR=2.94 [95% CI=2.54-3.40]) with high blood pressure. Body mass index, waist circumference, and waist to height ratio presented low sensitivity to identify adolescents with high blood pressure. However, adolescents classified with high body mass index, waist circumference, and waist to height ratio demonstrated a high association of presenting high blood pressure. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  4. Assessment of local pulse wave velocity distribution in mice using k-t BLAST PC-CMR with semi-automatic area segmentation.

    PubMed

    Herold, Volker; Herz, Stefan; Winter, Patrick; Gutjahr, Fabian Tobias; Andelovic, Kristina; Bauer, Wolfgang Rudolf; Jakob, Peter Michael

    2017-10-16

    Local aortic pulse wave velocity (PWV) is a measure for vascular stiffness and has a predictive value for cardiovascular events. Ultra high field CMR scanners allow the quantification of local PWV in mice, however these systems are yet unable to monitor the distribution of local elasticities. In the present study we provide a new accelerated method to quantify local aortic PWV in mice with phase-contrast cardiovascular magnetic resonance imaging (PC-CMR) at 17.6 T. Based on a k-t BLAST (Broad-use Linear Acquisition Speed-up Technique) undersampling scheme, total measurement time could be reduced by a factor of 6. The fast data acquisition enables to quantify the local PWV at several locations along the aortic blood vessel based on the evaluation of local temporal changes in blood flow and vessel cross sectional area. To speed up post processing and to eliminate operator bias, we introduce a new semi-automatic segmentation algorithm to quantify cross-sectional areas of the aortic vessel. The new methods were applied in 10 eight-month-old mice (4 C57BL/6J-mice and 6 ApoE (-/-) -mice) at 12 adjacent locations along the abdominal aorta. Accelerated data acquisition and semi-automatic post-processing delivered reliable measures for the local PWV, similiar to those obtained with full data sampling and manual segmentation. No statistically significant differences of the mean values could be detected for the different measurement approaches. Mean PWV values were elevated for the ApoE (-/-) -group compared to the C57BL/6J-group (3.5 ± 0.7 m/s vs. 2.2 ± 0.4 m/s, p < 0.01). A more heterogeneous PWV-distribution in the ApoE (-/-) -animals could be observed compared to the C57BL/6J-mice, representing the local character of lesion development in atherosclerosis. In the present work, we showed that k-t BLAST PC-MRI enables the measurement of the local PWV distribution in the mouse aorta. The semi-automatic segmentation method based on PC-CMR data allowed rapid determination of local PWV. The findings of this study demonstrate the ability of the proposed methods to non-invasively quantify the spatial variations in local PWV along the aorta of ApoE (-/-) -mice as a relevant model of atherosclerosis.

  5. Clinical comparison of automatic, noninvasive measurements of blood pressure in the forearm and upper arm.

    PubMed

    Schell, Kathleen; Bradley, Elisabeth; Bucher, Linda; Seckel, Maureen; Lyons, Denise; Wakai, Sandra; Bartell, Deborah; Carson, Elizabeth; Chichester, Melanie; Foraker, Teresa; Simpson, Kathleen

    2005-05-01

    When the upper arm (area from shoulder to elbow) is inaccessible and/or a standard-sized blood pressure cuff does not fit, some healthcare workers use the forearm to measure blood pressure. To compare automatic noninvasive measurements of blood pressure in the upper arm and forearm. A descriptive, correlational comparison study was conducted in the emergency department of a 1071-bed teaching hospital. Subjects were 204 English-speaking patients 6 to 91 years old in medically stable condition who had entered the department on foot or by wheelchair and who had no exclusions to using their left upper extremity. A Welch Allyn Vital Signs 420 series monitor was used to measure blood pressure in the left upper arm and forearm with the subject seated and the upper arm or forearm at heart level. Pearson r correlation coefficients between measurements in the upper arm and forearm were 0.88 for systolic blood pressure and 0.76 for diastolic blood pressure (P < .001 for both). Mean systolic pressures, but not mean diastolic pressures, in the upper arm and forearm differed significantly (t = 2.07, P = .04). A Bland-Altman analysis indicated that the distances between the mean values and the limits of agreement for the 2 sites ranged from 15 mm Hg (mean arterial pressure) to 18.4 mm Hg (systolic pressure). Despite strict attention to correct cuff size and placement of the upper arm or forearm at heart level, measurements of blood pressure obtained noninvasively in the arm and forearm of seated patients in stable condition are not interchangeable.

  6. Evaluation of the i-STAT Point-of-Care Analyzer in Critically Ill Adult Patients

    PubMed Central

    Steinfelder-Visscher, Jacoline; Teerenstra, Steven; Klein Gunnewiek, Jacqueline M.T.; Weerwind, Patrick W.

    2008-01-01

    Abstract: Point-of-care analyzers may benefit therapeutic decision making by reducing turn-around-time for samples. This is especially true when biochemical parameters exceed the clinical reference range, in which acute and effective treatment is essential. We therefore evaluated the analytical performance of the i-STAT point-of-care analyzer in two critically ill adult patient populations. During a 3-month period, 48 blood samples from patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) and 42 blood samples from non-cardiac patients who needed intensive care treatment were analyzed on both the i-STAT analyzer (CPB and non-CPB mode, respectively) and our laboratory analyzers (RapidLab 865/Sysmex XE-2100 instrument). The agreement analysis for quantitative data was used to compare i-STAT to RapidLab for blood gas/electrolytes and for hematocrit with the Sysmex instrument. Point-of-care electrolytes and blood gases had constant deviation, except for pH, pO2, and hematocrit. A clear linear trend in deviation of i-STAT from RapidLab was noticed for pH during CPB (r = 0.32, p = .03) and for pO2 > 10 kPa during CPB (r = −0.59, p < .0001 when 10 < pO2 <30 kPa) and in the intensive care unit (r = −0.61, p < .001 when 10 < pO2 <30 kPa). In the normal pO2 range (10.6 < pO2 <13.3 kPa), the performance of the i-STAT was comparable to the RapidLab. In contrast to hematocrit measured during CPB, hematocrit using the non-CPB mode in the non-cardiac intensive care population showed an underestimation up to 2.2% (p < .0001) in the hematocrit range below 25% (n = 11) using the i-STAT. The i-STAT analyzer is suitable for point-of-care testing of electrolytes and blood gases in critically ill patients, except for high pO2. However, the discrepancy in hematocrit bias shows that accuracy established in one patient population cannot be automatically extrapolated to other patient populations, thus stressing the need for separate evaluation. PMID:18389666

  7. An Analysis for Capital Expenditure Decisions at a Naval Regional Medical Center.

    DTIC Science & Technology

    1981-12-01

    Service Equipment Review Committee 1. Portable defibrilator Computed tomographic scanner and cardioscope 2. ECG cart Automated blood cell counter 3. Gas...system sterilizer Gas system sterilizer 4. Automated blood cell Portable defibrilator and counter cardioscope 5. Computed tomographic ECG cart scanner...dictating and automated typing) systems. e. Filing equipment f. Automatic data processing equipment including data communications equipment. g

  8. Automatic localization of the left ventricular blood pool centroid in short axis cardiac cine MR images.

    PubMed

    Tan, Li Kuo; Liew, Yih Miin; Lim, Einly; Abdul Aziz, Yang Faridah; Chee, Kok Han; McLaughlin, Robert A

    2018-06-01

    In this paper, we develop and validate an open source, fully automatic algorithm to localize the left ventricular (LV) blood pool centroid in short axis cardiac cine MR images, enabling follow-on automated LV segmentation algorithms. The algorithm comprises four steps: (i) quantify motion to determine an initial region of interest surrounding the heart, (ii) identify potential 2D objects of interest using an intensity-based segmentation, (iii) assess contraction/expansion, circularity, and proximity to lung tissue to score all objects of interest in terms of their likelihood of constituting part of the LV, and (iv) aggregate the objects into connected groups and construct the final LV blood pool volume and centroid. This algorithm was tested against 1140 datasets from the Kaggle Second Annual Data Science Bowl, as well as 45 datasets from the STACOM 2009 Cardiac MR Left Ventricle Segmentation Challenge. Correct LV localization was confirmed in 97.3% of the datasets. The mean absolute error between the gold standard and localization centroids was 2.8 to 4.7 mm, or 12 to 22% of the average endocardial radius. Graphical abstract Fully automated localization of the left ventricular blood pool in short axis cardiac cine MR images.

  9. Discrimination of liver cancer in cellular level based on backscatter micro-spectrum with PCA algorithm and BP neural network

    NASA Astrophysics Data System (ADS)

    Yang, Jing; Wang, Cheng; Cai, Gan; Dong, Xiaona

    2016-10-01

    The incidence and mortality rate of the primary liver cancer are very high and its postoperative metastasis and recurrence have become important factors to the prognosis of patients. Circulating tumor cells (CTC), as a new tumor marker, play important roles in the early diagnosis and individualized treatment. This paper presents an effective method to distinguish liver cancer based on the cellular scattering spectrum, which is a non-fluorescence technique based on the fiber confocal microscopic spectrometer. Combining the principal component analysis (PCA) with back propagation (BP) neural network were utilized to establish an automatic recognition model for backscatter spectrum of the liver cancer cells from blood cell. PCA was applied to reduce the dimension of the scattering spectral data which obtained by the fiber confocal microscopic spectrometer. After dimensionality reduction by PCA, a neural network pattern recognition model with 2 input layer nodes, 11 hidden layer nodes, 3 output nodes was established. We trained the network with 66 samples and also tested it. Results showed that the recognition rate of the three types of cells is more than 90%, the relative standard deviation is only 2.36%. The experimental results showed that the fiber confocal microscopic spectrometer combining with the algorithm of PCA and BP neural network can automatically identify the liver cancer cell from the blood cells. This will provide a better tool for investigating the metastasis of liver cancers in vivo, the biology metabolic characteristics of liver cancers and drug transportation. Additionally, it is obviously referential in practical application.

  10. Validation of semi-automatic segmentation of the left atrium

    NASA Astrophysics Data System (ADS)

    Rettmann, M. E.; Holmes, D. R., III; Camp, J. J.; Packer, D. L.; Robb, R. A.

    2008-03-01

    Catheter ablation therapy has become increasingly popular for the treatment of left atrial fibrillation. The effect of this treatment on left atrial morphology, however, has not yet been completely quantified. Initial studies have indicated a decrease in left atrial size with a concomitant decrease in pulmonary vein diameter. In order to effectively study if catheter based therapies affect left atrial geometry, robust segmentations with minimal user interaction are required. In this work, we validate a method to semi-automatically segment the left atrium from computed-tomography scans. The first step of the technique utilizes seeded region growing to extract the entire blood pool including the four chambers of the heart, the pulmonary veins, aorta, superior vena cava, inferior vena cava, and other surrounding structures. Next, the left atrium and pulmonary veins are separated from the rest of the blood pool using an algorithm that searches for thin connections between user defined points in the volumetric data or on a surface rendering. Finally, pulmonary veins are separated from the left atrium using a three dimensional tracing tool. A single user segmented three datasets three times using both the semi-automatic technique as well as manual tracing. The user interaction time for the semi-automatic technique was approximately forty-five minutes per dataset and the manual tracing required between four and eight hours per dataset depending on the number of slices. A truth model was generated using a simple voting scheme on the repeated manual segmentations. A second user segmented each of the nine datasets using the semi-automatic technique only. Several metrics were computed to assess the agreement between the semi-automatic technique and the truth model including percent differences in left atrial volume, DICE overlap, and mean distance between the boundaries of the segmented left atria. Overall, the semi-automatic approach was demonstrated to be repeatable within and between raters, and accurate when compared to the truth model. Finally, we generated a visualization to assess the spatial variability in the segmentation errors between the semi-automatic approach and the truth model. The visualization demonstrates the highest errors occur at the boundaries between the left atium and pulmonary veins as well as the left atrium and left atrial appendage. In conclusion, we describe a semi-automatic approach for left atrial segmentation that demonstrates repeatability and accuracy, with the advantage of significant time reduction in user interaction time.

  11. Headspace gas chromatographic method for the measurement of difluoroethane in blood.

    PubMed

    Broussard, L A; Broussard, A; Pittman, T; Lafferty, D; Presley, L

    2001-01-01

    To develop a gas chromatographic assay for the analysis of difluoroethane, a volatile substance, in blood and to determine assay characteristics including linearity, limit of quantitation, precision, and specificity. Referral toxicology laboratory Difluoroethane, a colorless, odorless, highly flammable gas used as a refrigerant blend component and aerosol propellant, may be abused via inhalation. A headspace gas chromatographic procedure for the identification and quantitation of difluoroethane in blood is presented. A methanolic stock standard prepared from pure gaseous difluoroethane was used to prepare whole blood calibrators. Quantitation of difluoroethane was performed using a six-point calibration curve and an internal standard of 1-propanol. The assay is linear from 0 to 115 mg/L including a low calibrator at 4 mg/L, the limit of quantitation. Within-run coefficients of variation at mean concentrations of 13.8 mg/L and 38.5 mg/L were 5.8% and 6.8% respectively. Between-run coefficients of variation at mean concentrations of 15.9 mg/L and 45.7 mg/L were 13.4% and 9.8% respectively. Several volatile substances were tested as potential interfering compounds with propane having a retention time identical to that of difluoroethane. This method requires minimal sample preparation, is rapid and reproducible, can be modified for the quantitation of other volatiles, and could be automated using an automatic sampler/injector system.

  12. Fast and robust segmentation of white blood cell images by self-supervised learning.

    PubMed

    Zheng, Xin; Wang, Yong; Wang, Guoyou; Liu, Jianguo

    2018-04-01

    A fast and accurate white blood cell (WBC) segmentation remains a challenging task, as different WBCs vary significantly in color and shape due to cell type differences, staining technique variations and the adhesion between the WBC and red blood cells. In this paper, a self-supervised learning approach, consisting of unsupervised initial segmentation and supervised segmentation refinement, is presented. The first module extracts the overall foreground region from the cell image by K-means clustering, and then generates a coarse WBC region by touching-cell splitting based on concavity analysis. The second module further uses the coarse segmentation result of the first module as automatic labels to actively train a support vector machine (SVM) classifier. Then, the trained SVM classifier is further used to classify each pixel of the image and achieve a more accurate segmentation result. To improve its segmentation accuracy, median color features representing the topological structure and a new weak edge enhancement operator (WEEO) handling fuzzy boundary are introduced. To further reduce its time cost, an efficient cluster sampling strategy is also proposed. We tested the proposed approach with two blood cell image datasets obtained under various imaging and staining conditions. The experiment results show that our approach has a superior performance of accuracy and time cost on both datasets. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Automatic diagnosis of malaria based on complete circle-ellipse fitting search algorithm.

    PubMed

    Sheikhhosseini, M; Rabbani, H; Zekri, M; Talebi, A

    2013-12-01

    Diagnosis of malaria parasitemia from blood smears is a subjective and time-consuming task for pathologists. The automatic diagnostic process will reduce the diagnostic time. Also, it can be worked as a second opinion for pathologists and may be useful in malaria screening. This study presents an automatic method for malaria diagnosis from thin blood smears. According to this fact that malaria life cycle is started by forming a ring around the parasite nucleus, the proposed approach is mainly based on curve fitting to detect parasite ring in the blood smear. The method is composed of six main phases: stain object extraction step, which extracts candidate objects that may be infected by malaria parasites. This phase includes stained pixel extraction step based on intensity and colour, and stained object segmentation by defining stained circle matching. Second step is preprocessing phase which makes use of nonlinear diffusion filtering. The process continues with detection of parasite nucleus from resulted image of previous step according to image intensity. Fourth step introduces a complete search process in which the circle search step identifies the direction and initial points for direct least-square ellipse fitting algorithm. Furthermore in the ellipse searching process, although parasite shape is completed undesired regions with high error value are removed and ellipse parameters are modified. Features are extracted from the parasite candidate region instead of whole candidate object in the fifth step. By employing this special feature extraction way, which is provided by special searching process, the necessity of employing clump splitting methods is removed. Also, defining stained circle matching process in the first step speeds up the whole procedure. Finally, a series of decision rules are applied on the extracted features to decide on the positivity or negativity of malaria parasite presence. The algorithm is applied on 26 digital images which are provided from thin blood smear films. The images are contained 1274 objects which may be infected by parasite or healthy. Applying the automatic identification of malaria on provided database showed a sensitivity of 82.28% and specificity of 98.02%. © 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.

  14. Automatic Detection of Mitosis and Nuclei From Cytogenetic Images by CellProfiler Software for Mitotic Index Estimation.

    PubMed

    González, Jorge Ernesto; Radl, Analía; Romero, Ivonne; Barquinero, Joan Francesc; García, Omar; Di Giorgio, Marina

    2016-12-01

    Mitotic Index (MI) estimation expressed as percentage of mitosis plays an important role as quality control endpoint. To this end, MI is applied to check the lot of media and reagents to be used throughout the assay and also to check cellular viability after blood sample shipping, indicating satisfactory/unsatisfactory conditions for the progression of cell culture. The objective of this paper was to apply the CellProfiler open-source software for automatic detection of mitotic and nuclei figures from digitized images of cultured human lymphocytes for MI assessment, and to compare its performance to that performed through semi-automatic and visual detection. Lymphocytes were irradiated and cultured for mitosis detection. Sets of images from cultures were analyzed visually and findings were compared with those using CellProfiler software. The CellProfiler pipeline includes the detection of nuclei and mitosis with 80% sensitivity and more than 99% specificity. We conclude that CellProfiler is a reliable tool for counting mitosis and nuclei from cytogenetic images, saves considerable time compared to manual operation and reduces the variability derived from the scoring criteria of different scorers. The CellProfiler automated pipeline achieves good agreement with visual counting workflow, i.e. it allows fully automated mitotic and nuclei scoring in cytogenetic images yielding reliable information with minimal user intervention. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. An automatic fuzzy-based multi-temporal brain digital subtraction angiography image fusion algorithm using curvelet transform and content selection strategy.

    PubMed

    Momeni, Saba; Pourghassem, Hossein

    2014-08-01

    Recently image fusion has prominent role in medical image processing and is useful to diagnose and treat many diseases. Digital subtraction angiography is one of the most applicable imaging to diagnose brain vascular diseases and radiosurgery of brain. This paper proposes an automatic fuzzy-based multi-temporal fusion algorithm for 2-D digital subtraction angiography images. In this algorithm, for blood vessel map extraction, the valuable frames of brain angiography video are automatically determined to form the digital subtraction angiography images based on a novel definition of vessel dispersion generated by injected contrast material. Our proposed fusion scheme contains different fusion methods for high and low frequency contents based on the coefficient characteristic of wrapping second generation of curvelet transform and a novel content selection strategy. Our proposed content selection strategy is defined based on sample correlation of the curvelet transform coefficients. In our proposed fuzzy-based fusion scheme, the selection of curvelet coefficients are optimized by applying weighted averaging and maximum selection rules for the high frequency coefficients. For low frequency coefficients, the maximum selection rule based on local energy criterion is applied to better visual perception. Our proposed fusion algorithm is evaluated on a perfect brain angiography image dataset consisting of one hundred 2-D internal carotid rotational angiography videos. The obtained results demonstrate the effectiveness and efficiency of our proposed fusion algorithm in comparison with common and basic fusion algorithms.

  16. Assessment of anaerobic blood cultures in pediatric oncology patients.

    PubMed

    Monsonís Cabedo, Manuel; Rives Solá, Susana; Noguera-Julian, Antoni; Urrea Ayala, Mireia; Cruz Martinez, Ofelia; Gené Giralt, Amadeu

    2017-01-01

    The routine use of a single aerobic bottle for blood culture in pediatric patients has become commonplace, as anaerobic bacteria are not frequently involved in clinically significant infections. The aim of this study was to assess the usefulness of routinely performing anaerobic blood cultures in pediatric oncology patients. Prospective study was conducted on pediatric (<18 years) patients affected with febrile syndrome after receiving chemotherapy for hematological or solid malignancies. Samples were inoculated into pediatric aerobic and standard anaerobic bottles (BacT/Alert automatic system). Strains were considered clinically significant, or deemed as contaminants, depending on isolation circumstances and clinical criteria. A total of 876 blood cultures from 228 patients were processed during the 21-month study period (January 2014 to September 2015). Baseline diagnosis included 143 solid tumors and 67/18 cases of leukemia/lymphoma. Bacterial growth was detected in 90 (10.2%) blood cultures for 95 different isolates, of which 62 (7.1%)/63 isolates were considered clinically significant. Among the latter, 38 (60.3%) microorganisms grew in both aerobic and anaerobic bottles, 18 (28.6%) only in aerobic bottles, and 7 (11.1%) only in anaerobic bottles. Gram-negative bacilli (33; 52.4%), mainly from the Enterobacteriaceae family, were the most frequently isolated microorganisms. Overall, only 3 out of 90 isolates (3.3%) were strict anaerobes (Propionibacterium acnes), and all of them were deemed contaminants. Strict anaerobes did not cause significant infections in febrile pediatric oncology patients, and anaerobic blood culture bottles offered no additional advantages over aerobic media. Our results suggest that routine blood cultures should be solely processed in aerobic media in this group of patients. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  17. The effectiveness of BD Vacutainer® Plus Urinalysis Preservative Tubes in preservation of urine for chemical strip analysis and particle counting.

    PubMed

    Ekşioğlu, Merve Kaymak; Madenci, Özlem Çakır; Yücel, Nihal; Elçi, Abdullah; Turhan, Bülent; Orhan, Gani; Orçun, Asuman

    2016-01-01

    The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. 275 pathologic urine specimens were included. Each urine sample was evaluated after 4, 8, 12, 24, and 48 hours of storage in BD Vacutainer(®) Plus Urinalysis Preservative (BD UAP) tubes and compared with refrigeration at 4 °C. All analyses were peformed on H-800 and FUS-200 automatic modular urine analyzers (Dirui Industry, Changchun, China). The kappa coefficients (κ), false positive (FP) and false negative (FN) rates were evaluated. κ > 0.8 was accepted as good agreement. Haemoglobin (Hb), leucocyte esterase (LE), and protein (Pro) analyses should be performed within 4 hours, whereas glucose (Glc) was stable until the end of 48 hours in both storage conditions. Nitrite (Nit) was well preserved in BD UAP tubes for 24 hours but was stable only up to 8 hours at 4 °C. Bilirubin (Bil) had very high FN rates even at 4 hours in both conditions. The particle counting showed high FN rates for white blood cells (WBC) and red blood cells (RBC), whereas squamous epithelial cells (EC) were stable up to 8 hours in both conditions. Preanalytical requirements for both urine chemical strip analyses and particle counting in a unique sample were not met in either condition. Thus, the transfer of urine samples for centralization of urinalysis is not yet feasible.

  18. The impact of automatic devices for capillary blood collection on efficiency and pain response in newborns: A randomized controlled trial.

    PubMed

    Sorrentino, G; Fumagalli, M; Milani, S; Cortinovis, I; Zorz, A; Cavallaro, G; Mosca, F; Plevani, L

    2017-07-01

    The heel stick is the method of choice in most neonatal units for capillary blood sampling, and it represents the most common event among all painful procedures performed on newborns. The type and design of heel stick device and the clinical procedure to collect a blood sample may have an impact on newborn pain response as well. To compare the pain response and efficiency of different automated devices for capillary blood collection in newborns. Randomized clinical trial. Postnatal ward of a tertiary-care university hospital in Italy. Newborn infants at gestational age ≥34 weeks undergoing the metabolic screening test after the 49th hour of life. A total of 762 neonates were recruited and randomized into 6 groups (127 babies in each group) assigned to 6 different capillary blood collection devices (Ames Minilet™ Lancet; Cardinal Health Gentleheel ® ; Natus Medical NeatNick™; BD Quikheel™ Lancet; Vitrex Steriheel ® Baby Lancet; Accriva Diagnostics Tenderfoot ® ). The following data were collected and assessed for each of the 6 groups evaluated: a) number of heel sticks, b) pain score according to the Neonatal Infant Pain Scale (NIPS) and c) need to squeeze the heel. The Ames Minilet™ Lancet device was found to perform by far the worst compared to the five device underexamination: it required the highest number of sticks (mean=3.91; 95% CI: 3.46-4.36), evoked the most intense pain (mean=3.98; 95% CI: 3.77-4.20), and most frequently necessitated squeezing the heel (92.9%; 95% CI: 86.9-96.3). The five devices under examination appeared to be similar in terms of the number of sticks required, but differed slightly in NIPS score and in need to squeeze the heel. The Accriva Diagnostics Tenderfoot ® device demonstrated the greatest efficiency for blood sampling and evoked the least pain. With this device, the metabolic screening test could be performed with a single skin incision in the large majority of infants (98.4%), heel squeezing was limited to only 6.3% of infants, and the NIPS score turns out to be lower than other devices in our study (1.22; 95% CI 1.05-1.39). Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Validation of the Pangao PG-800A36 automatic wrist blood pressure monitor according to the European Society of Hypertension and the British Hypertension Society protocols.

    PubMed

    Zhao, Hairong; Qiao, Weichang; Zhang, Rui; Cui, Peng; Hou, Fanglin; Zhang, Wenli

    2018-02-01

    The aim of this study was to validate the PG-800A36 automatic wrist blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the British Hypertension Society (BHS) protocols. A total of 33 participants were initially included on the basis of the ESH-IP, followed by examination of 85 participants according to the BHS protocol. The procedures and analysis methods of the protocols were followed precisely with left arm/wrist sequential measurements by two trained observers using a mercury sphygmomanometer and one supervisor using the device. The device passed the ESH-IP with an average difference of 1.45±6.46 mmHg for systolic blood pressure and 1.25±5.10 mmHg for diastolic blood pressure. Furthermore, the A/A grade of the BHS protocol was achieved with an average difference of 1.84±6.94 mmHg for systolic blood pressure and 1.15±6.49 mmHg for diastolic blood pressure, and thus, the device also fulfilled the requirements of the Association for the Advancement of Medical Instrumentation. The Pangao PG-800A36 passed the requirements of the ESH-IP revision 2010 and achieved the A/A grade of the BHS protocol, which can be recommended for self-measurement in the general population.

  20. A Simple Laboratory Experiment to Determine the Kinetics of Mutarotation of D-Glucose Using a Blood Glucose Meter

    ERIC Educational Resources Information Center

    Perles, Carlos E.; Volpe, Pedro L. O.

    2008-01-01

    A simple commercial blood glucose meter is used to follow the kinetics of mutarotation of D-glucose in aqueous solution. The results may be compared with those obtained using an automatic polarimeter, if this is available This experiment is proposed for use by students in a general chemistry, biology, organic chemistry, and physical chemistry…

  1. Lead Exposure in Military Outdoor Firing Ranges.

    PubMed

    Greenberg, Nili; Frimer, Ron; Meyer, Robert; Derazne, Estella; Chodick, Gabrial

    2016-09-01

    Several studies have reported significant airborne lead exposures during training at indoor firing ranges. Scarce attention has been given to airborne lead exposures in outdoor shooting ranges with automatic weapons. To assess the prevalence and magnitude of airborne and blood lead levels (BLL) among firing instructors and shooters in military outdoor ranges. Exposure assessment, for both trainees and instructors, included airborne and BLL during basic and advanced training at outdoor firing ranges. Personal airborne samples were collected in both day and night shooting during both training periods. During basic training, there is 95% likelihood that up to 25% of instructors and 99% likelihood that up to 5% of trainees might be exposed above the action level (AL) (25 μg/m(3)). During advanced training, there is 90% likelihood that 10% of instructors and 99% likelihood that up to 10% of trainees might be exposed above the AL. Military personnel participating in automatic weapon marksmanship training can be exposed to considerable levels of airborne lead during outdoor firing range training. As a result, the Israel Defense Force Medical Corp has classified firing range instructors as workers that require periodic medical examinations. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  2. AN ASSESSMENT OF AUTOMATIC SEWER FLOW SAMPLERS (EPA/600/2-75/065)

    EPA Science Inventory

    A brief review of the characteristics of storm and combined sewer flows is given followed by a general discussion of the purposes for and requirements of a sampling program. The desirable characteristics of automatic sampling equipment are set forth and problem areas are outlined...

  3. Stair Descending Exercise Using a Novel Automatic Escalator: Effects on Muscle Performance and Health-Related Parameters

    PubMed Central

    Paschalis, Vassilis; Theodorou, Anastasios A.; Panayiotou, George; Kyparos, Antonios; Patikas, Dimitrios; Grivas, Gerasimos V.; Nikolaidis, Michalis G.; Vrabas, Ioannis S.

    2013-01-01

    A novel automatic escalator was designed, constructed and used in the present investigation. The aim of the present investigation was to compare the effect of two repeated sessions of stair descending versus stair ascending exercise on muscle performance and health-related parameters in young healthy men. Twenty males participated and were randomly divided into two equal-sized groups: a stair descending group (muscle-damaging group) and a stair ascending group (non-muscle-damaging group). Each group performed two sessions of stair descending or stair ascending exercise on the automatic escalator while a three week period was elapsed between the two exercise sessions. Indices of muscle function, insulin sensitivity, blood lipid profile and redox status were assessed before and immediately after, as well as at day 2 and day 4 after both exercise sessions. It was found that the first bout of stair descending exercise caused muscle damage, induced insulin resistance and oxidative stress as well as affected positively blood lipid profile. However, after the second bout of stair descending exercise the alterations in all parameters were diminished or abolished. On the other hand, the stair ascending exercise induced only minor effects on muscle function and health-related parameters after both exercise bouts. The results of the present investigation indicate that stair descending exercise seems to be a promising way of exercise that can provoke positive effects on blood lipid profile and antioxidant status. PMID:23437093

  4. Hemodiafiltration: Technical and Clinical Issues.

    PubMed

    Ronco, Claudio

    2015-01-01

    Hemodiafiltration (HDF) seems to represent the gold standard in the field of replacement of renal function by dialysis. High convective fluxes have been correlated with better clinical outcomes. Sometimes, however, there are technical barriers to the achievement of high blood flows adequate to perform effective convective therapies. In spite of optimized procedures, the progressive increase in transmembrane pressure (TMP), the blood viscosity due to hemoconcentration and blood path resistance sometimes becomes inevitable. We propose two possible solutions that can be operated automatically via specific software in the dialysis machine: predilution on demand and backflush on demand. Predilution on demand consists in an automatic feedback of the machine, diverting part of the filtered dialysate into a predilution mode with an infusion of 200 ml in 30 s while the ultrafiltration pump stops. This produces a sudden hemodilution with a return of the parameters to acceptable values. The performance of the filter improves, and the pressure alterations are mitigated. Backflush on demand consists in an automatic feedback of the machine triggered by the TMP control, producing a positive pressure in the dialysate compartment due to a stop of filtration and rapid infusion of at least 100 ml of ultrapure dialysate into the hollow fiber. This not only produces a significant hemodilution, but also backflushes the membrane pores detaching protein layers and improving membrane permeability. These are two examples of how technology will permit to overcome technical barriers to a widespread diffusion of HDF and adequate convective dose delivery. © 2015 S. Karger AG, Basel.

  5. Volumetric vessel reconstruction method for absolute blood flow velocity measurement in Doppler OCT images

    NASA Astrophysics Data System (ADS)

    Qi, Li; Zhu, Jiang; Hancock, Aneeka M.; Dai, Cuixia; Zhang, Xuping; Frostig, Ron D.; Chen, Zhongping

    2017-02-01

    Doppler optical coherence tomography (DOCT) is considered one of the most promising functional imaging modalities for neuro biology research and has demonstrated the ability to quantify cerebral blood flow velocity at a high accuracy. However, the measurement of total absolute blood flow velocity (BFV) of major cerebral arteries is still a difficult problem since it not only relates to the properties of the laser and the scattering particles, but also relates to the geometry of both directions of the laser beam and the flow. In this paper, focusing on the analysis of cerebral hemodynamics, we presents a method to quantify the total absolute blood flow velocity in middle cerebral artery (MCA) based on volumetric vessel reconstruction from pure DOCT images. A modified region growing segmentation method is first used to localize the MCA on successive DOCT B-scan images. Vessel skeletonization, followed by an averaging gradient angle calculation method, is then carried out to obtain Doppler angles along the entire MCA. Once the Doppler angles are determined, the absolute blood flow velocity of each position on the MCA is easily found. Given a seed point position on the MCA, our approach could achieve automatic quantification of the fully distributed absolute BFV. Based on experiments conducted using a swept-source optical coherence tomography system, our approach could achieve automatic quantification of the fully distributed absolute BFV across different vessel branches in the rodent brain.

  6. On the Relationship Between Automatic Attitudes and Self-Reported Sexual Assault in Men

    PubMed Central

    Widman, Laura; Olson, Michael

    2013-01-01

    Research and theory suggest rape supportive attitudes are important predictors of sexual assault; yet, to date, rape supportive attitudes have been assessed exclusively through self-report measures that are methodologically and theoretically limited. To address these limitations, the objectives of the current project were to: (1) develop a novel implicit rape attitude assessment that captures automatic attitudes about rape and does not rely on self-reports, and (2) examine the association between automatic rape attitudes and sexual assault perpetration. We predicted that automatic rape attitudes would be a significant unique predictor of sexual assault even when self-reported rape attitudes (i.e., rape myth acceptance and hostility toward women) were controlled. We tested the generalizability of this prediction in two independent samples: a sample of undergraduate college men (n = 75, M age = 19.3 years) and a sample of men from the community (n = 50, M age = 35.9 years). We found the novel implicit rape attitude assessment was significantly associated with the frequency of sexual assault perpetration in both samples and contributed unique variance in explaining sexual assault beyond rape myth acceptance and hostility toward women. We discuss the ways in which future research on automatic rape attitudes may significantly advance measurement and theory aimed at understanding and preventing sexual assault. PMID:22618119

  7. Highly sensitive and multiplexed platforms for allergy diagnostics

    NASA Astrophysics Data System (ADS)

    Monroe, Margo R.

    Allergy is a disorder of the immune system caused by an immune response to otherwise harmless environmental allergens. Currently 20% of the US population is allergic and 90% of pediatric patients and 60% of adult patients with asthma have allergies. These percentages have increased by 18.5% in the past decade, with predicted similar trends for the future. Here we design sensitive, multiplexed platforms to detect allergen-specific IgE using the Interferometric Reflectance Imaging Sensor (IRIS) for various clinical settings. A microarray platform for allergy diagnosis allows for testing of specific IgE sensitivity to a multitude of allergens, while requiring only small volumes of patient blood sample. However, conventional fluorescent microarray technology is limited by i) the variation of probe immobilization, which hinders the ability to make quantitative, assertive, and statistically relevant conclusions necessary in immunodiagnostics and ii) the use of fluorophore labels, which is not suitable for some clinical applications due to the tendency of fluorophores to stick to blood particulates and require daily calibration methods. This calibrated fluorescence enhancement (CaFE) method integrates the low magnification modality of IRIS with enhanced fluorescence sensing in order to directly correlate immobilized probe (major allergens) density to allergen-specific IgE in patient serum. However, this platform only operates in processed serum samples, which is not ideal for point of care testing. Thus, a high magnification modality of IRIS was adapted as an alternative allergy diagnostic platform to automatically discriminate and size single nanoparticles bound to specific IgE in unprocessed, characterized human blood and serum samples. These features make IRIS an ideal candidate for clinical and diagnostic applications, such a POC testing. The high magnification (nanoparticle counting) modality in conjunction with low magnification of IRIS in a combined instrument offers four significant advantages compared to existing sensing technologies: IRIS i) corrects for any variation in probe immobilization, ii) detects proteins from attomolar to nanomolar concentrations in unprocessed biological samples, iii) unambiguously discriminates nanoparticles tags on a robust and physically large sensor area, iv) detects protein targets with conjugated nanoparticle tags (~40nm diameter), which minimally affect assay kinetics compared to conventional microparticle tagging methods, and v) utilizes components that make the instrument inexpensive, robust, and portable. This platform was successfully validated on patient serum and whole blood samples with documented allergy profiles (ImmunoCAPRTM, ThermoFisher Scientific).

  8. 46 CFR 161.002-2 - Types of fire-protective systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., but not be limited to, automatic fire and smoke detecting systems, manual fire alarm systems, sample extraction smoke detection systems, watchman's supervisory systems, and combinations of these systems. (b) Automatic fire detecting systems. For the purpose of this subpart, automatic fire and smoke detecting...

  9. 46 CFR 161.002-2 - Types of fire-protective systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., but not be limited to, automatic fire and smoke detecting systems, manual fire alarm systems, sample extraction smoke detection systems, watchman's supervisory systems, and combinations of these systems. (b) Automatic fire detecting systems. For the purpose of this subpart, automatic fire and smoke detecting...

  10. [Automatic adjustment control system for DC glow discharge plasma source].

    PubMed

    Wan, Zhen-zhen; Wang, Yong-qing; Li, Xiao-jia; Wang, Hai-zhou; Shi, Ning

    2011-03-01

    There are three important parameters in the DC glow discharge process, the discharge current, discharge voltage and argon pressure in discharge source. These parameters influence each other during glow discharge process. This paper presents an automatic control system for DC glow discharge plasma source. This system collects and controls discharge voltage automatically by adjusting discharge source pressure while the discharge current is constant in the glow discharge process. The design concept, circuit principle and control program of this automatic control system are described. The accuracy is improved by this automatic control system with the method of reducing the complex operations and manual control errors. This system enhances the control accuracy of glow discharge voltage, and reduces the time to reach discharge voltage stability. The glow discharge voltage stability test results with automatic control system are provided as well, the accuracy with automatic control system is better than 1% FS which is improved from 4% FS by manual control. Time to reach discharge voltage stability has been shortened to within 30 s by automatic control from more than 90 s by manual control. Standard samples like middle-low alloy steel and tin bronze have been tested by this automatic control system. The concentration analysis precision has been significantly improved. The RSDs of all the test result are better than 3.5%. In middle-low alloy steel standard sample, the RSD range of concentration test result of Ti, Co and Mn elements is reduced from 3.0%-4.3% by manual control to 1.7%-2.4% by automatic control, and that for S and Mo is also reduced from 5.2%-5.9% to 3.3%-3.5%. In tin bronze standard sample, the RSD range of Sn, Zn and Al elements is reduced from 2.6%-4.4% to 1.0%-2.4%, and that for Si, Ni and Fe is reduced from 6.6%-13.9% to 2.6%-3.5%. The test data is also shown in this paper.

  11. Automation system for measurement of gamma-ray spectra of induced activity for multi-element high volume neutron activation analysis at the reactor IBR-2 of Frank Laboratory of Neutron Physics at the joint institute for nuclear research

    NASA Astrophysics Data System (ADS)

    Pavlov, S. S.; Dmitriev, A. Yu.; Chepurchenko, I. A.; Frontasyeva, M. V.

    2014-11-01

    The automation system for measurement of induced activity of gamma-ray spectra for multi-element high volume neutron activation analysis (NAA) was designed, developed and implemented at the reactor IBR-2 at the Frank Laboratory of Neutron Physics. The system consists of three devices of automatic sample changers for three Canberra HPGe detector-based gamma spectrometry systems. Each sample changer consists of two-axis of linear positioning module M202A by DriveSet company and disk with 45 slots for containers with samples. Control of automatic sample changer is performed by the Xemo S360U controller by Systec company. Positioning accuracy can reach 0.1 mm. Special software performs automatic changing of samples and measurement of gamma spectra at constant interaction with the NAA database.

  12. White blood cell subsets are associated with carotid intima-media thickness and pulse wave velocity in an older Chinese population: the Guangzhou Biobank Cohort Study.

    PubMed

    Phillips, A C; Jiang, C Q; Thomas, G N; Lin, J M; Yue, X J; Cheng, K K; Jin, Y L; Zhang, W S; Lam, T H

    2012-08-01

    Cross-sectional associations between white blood cell (WBC) count, lymphocyte and granulocyte numbers, and carotid intima-media thickness (IMT) and brachial-ankle pulse wave velocity (PWV) were examined in a novel older Chinese community sample. A total of 817 men and 760 women from a sub-study of the Guangzhou Biobank Cohort Study had a full blood count measured by an automated hematology analyzer, carotid IMT by B-mode ultrasonography and brachial-ankle PWV by a non-invasive automatic waveform analyzer. Following adjustment for confounders, WBC count (β=0.07, P<0.001) and granulocyte (β=0.07, P<0.001) number were significantly positively related to PWV, but not lymphocyte number. Similarly, WBC count (β=0.08, P=0.03), lymphocyte (β=0.08, P=0.002) and granulocyte (β=0.03, P=0.04) number were significantly positively associated with carotid IMT, but only the association with lymphocyte count survived correction for other cardiovascular risk factors. In conclusion, higher WBC, particularly lymphocyte and granulocyte, count could be used, respectively, as markers of cardiovascular disease risk, measured through indicators of atherosclerosis and arterial stiffness. The associations for WBC count previously observed by others were likely driven by higher granulocytes; an index of systemic inflammation.

  13. Exclusion-Based Capture and Enumeration of CD4+ T Cells from Whole Blood for Low-Resource Settings.

    PubMed

    Howard, Alexander L; Pezzi, Hannah M; Beebe, David J; Berry, Scott M

    2014-06-01

    In developing countries, demand exists for a cost-effective method to evaluate human immunodeficiency virus patients' CD4(+) T-helper cell count. The TH (CD4) cell count is the current marker used to identify when an HIV patient has progressed to acquired immunodeficiency syndrome, which results when the immune system can no longer prevent certain opportunistic infections. A system to perform TH count that obviates the use of costly flow cytometry will enable physicians to more closely follow patients' disease progression and response to therapy in areas where such advanced equipment is unavailable. Our system of two serially-operated immiscible phase exclusion-based cell isolations coupled with a rapid fluorescent readout enables exclusion-based isolation and accurate counting of T-helper cells at lower cost and from a smaller volume of blood than previous methods. TH cell isolation via immiscible filtration assisted by surface tension (IFAST) compares well against the established Dynal T4 Quant Kit and is sensitive at CD4 counts representative of immunocompromised patients (less than 200 TH cells per microliter of blood). Our technique retains use of open, simple-to-operate devices that enable IFAST as a high-throughput, automatable sample preparation method, improving throughput over previous low-resource methods. © 2013 Society for Laboratory Automation and Screening.

  14. Isotopic (d18O/d2H) integrity of water samples collected and stored by automatic samplers

    USDA-ARS?s Scientific Manuscript database

    Stable water isotopes are increasingly becoming part of routine monitoring programs that utilize automatic samplers. The objectives of this study were to quantify the uncertainty in isotope signatures due to the length of sample storage (1-24 d) inside autosamplers over a range of air temperatures (...

  15. Quantitation of cocaine and cocaethylene in small volumes of rat whole blood using gas chromatography-mass spectrometry.

    PubMed

    Burdick, J D; Boni, R L; Fochtman, F W

    1997-05-01

    A simple solid phase extraction (SPE) technique combined with gas chromatography-mass spectrometry (GC/MS) operated in selected ion monitoring (SIM) mode is described for quantitation of cocaine and cocaethylene in small samples (250 microliters) of rat whole blood. Use of (N-[2H3C])-cocaine and (N-[2H3C])-cocaethylene internal standards resulted in high sensitivity and selectivity for this analytical method. Analysis was performed using a Hewlett-Packard 5890 GC equipped with a 7673A Automatic Liquid Sampler linked to a Hewlett-Packard 5972 Mass Selective Detector. Separation of analytes was accomplished on a cross-linked methyl silicone gum capillary column (Ultra 1: 12m x 0.2mm (i.d.) x 0.33 microns). Linearity was established over a wide range of concentrations (5.0-2000.0 ng ml-1) with good precision. Limits of detection (LOD) were 1.0 and 2.0 ng ml-1 for cocaine and cocaethylene, respectively. This analytical method was designed for use in pharmacokinetic experiments studying the formation of cocaethylene following ethanol pretreatment in rats administered cocaine.

  16. Occupational Survey Report. AFSC 4A2X1 Biomedical Equipment

    DTIC Science & Technology

    2004-05-01

    Electrocardiograms 70 Hospital Beds, Electric 67 Surgical Lamps 67 Hospital Beds, Manual 66 Audiometers 64 Dental Curing Units 63 Dental Handpieces 63...Pumps 78 Pulse Oximeters 78 Dental Chairs 76 Blood Pressure Monitors, Automatic 74 Examination Lamps 72 Examination Tables 72 Blood Pressure Cuffs 71...Exercise Bicycles 63 Dental Amalgamators 62 Scales or Balances, other than Pediatric 62 Scales or Balances, Pediatric 61 First-Enlistment Personnel

  17. Ridge-branch-based blood vessel detection algorithm for multimodal retinal images

    NASA Astrophysics Data System (ADS)

    Li, Y.; Hutchings, N.; Knighton, R. W.; Gregori, G.; Lujan, B. J.; Flanagan, J. G.

    2009-02-01

    Automatic detection of retinal blood vessels is important to medical diagnoses and imaging. With the development of imaging technologies, various modals of retinal images are available. Few of currently published algorithms are applied to multimodal retinal images. Besides, the performance of algorithms with pathologies is expected to be improved. The purpose of this paper is to propose an automatic Ridge-Branch-Based (RBB) detection algorithm of blood vessel centerlines and blood vessels for multimodal retinal images (color fundus photographs, fluorescein angiograms, fundus autofluorescence images, SLO fundus images and OCT fundus images, for example). Ridges, which can be considered as centerlines of vessel-like patterns, are first extracted. The method uses the connective branching information of image ridges: if ridge pixels are connected, they are more likely to be in the same class, vessel ridge pixels or non-vessel ridge pixels. Thanks to the good distinguishing ability of the designed "Segment-Based Ridge Features", the classifier and its parameters can be easily adapted to multimodal retinal images without ground truth training. We present thorough experimental results on SLO images, color fundus photograph database and other multimodal retinal images, as well as comparison between other published algorithms. Results showed that the RBB algorithm achieved a good performance.

  18. Changes in default mode network as automaticity develops in a categorization task.

    PubMed

    Shamloo, Farzin; Helie, Sebastien

    2016-10-15

    The default mode network (DMN) is a set of brain regions in which blood oxygen level dependent signal is suppressed during attentional focus on the external environment. Because automatic task processing requires less attention, development of automaticity in a rule-based categorization task may result in less deactivation and altered functional connectivity of the DMN when compared to the initial learning stage. We tested this hypothesis by re-analyzing functional magnetic resonance imaging data of participants trained in rule-based categorization for over 10,000 trials (Helie et al., 2010) [12,13]. The results show that some DMN regions are deactivated in initial training but not after automaticity has developed. There is also a significant decrease in DMN deactivation after extensive practice. Seed-based functional connectivity analyses with the precuneus, medial prefrontal cortex (two important DMN regions) and Brodmann area 6 (an important region in automatic categorization) were also performed. The results show increased functional connectivity with both DMN and non-DMN regions after the development of automaticity, and a decrease in functional connectivity between the medial prefrontal cortex and ventromedial orbitofrontal cortex. Together, these results further support the hypothesis of a strategy shift in automatic categorization and bridge the cognitive and neuroscientific conceptions of automaticity in showing that the reduced need for cognitive resources in automatic processing is accompanied by a disinhibition of the DMN and stronger functional connectivity between DMN and task-related brain regions. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Strategies for rare-event detection: an approach for automated fetal cell detection in maternal blood.

    PubMed Central

    Oosterwijk, J C; Knepflé, C F; Mesker, W E; Vrolijk, H; Sloos, W C; Pattenier, H; Ravkin, I; van Ommen, G J; Kanhai, H H; Tanke, H J

    1998-01-01

    This article explores the feasibility of the use of automated microscopy and image analysis to detect the presence of rare fetal nucleated red blood cells (NRBCs) circulating in maternal blood. The rationales for enrichment and for automated image analysis for "rare-event" detection are reviewed. We also describe the application of automated image analysis to 42 maternal blood samples, using a protocol consisting of one-step enrichment followed by immunocytochemical staining for fetal hemoglobin (HbF) and FISH for X- and Y-chromosomal sequences. Automated image analysis consisted of multimode microscopy and subsequent visual evaluation of image memories containing the selected objects. The FISH results were compared with the results of conventional karyotyping of the chorionic villi. By use of manual screening, 43% of the slides were found to be positive (>=1 NRBC), with a mean number of 11 NRBCs (range 1-40). By automated microscopy, 52% were positive, with on average 17 NRBCs (range 1-111). There was a good correlation between both manual and automated screening, but the NRBC yield from automated image analysis was found to be superior to that from manual screening (P=.0443), particularly when the NRBC count was >15. Seven (64%) of 11 XY fetuses were correctly diagnosed by FISH analysis of automatically detected cells, and all discrepancies were restricted to the lower cell-count range. We believe that automated microscopy and image analysis reduce the screening workload, are more sensitive than manual evaluation, and can be used to detect rare HbF-containing NRBCs in maternal blood. PMID:9837832

  20. Validation of a computerized technique for automatically tracking and measuring the inferior vena cava in ultrasound imagery.

    PubMed

    Bellows, Spencer; Smith, Jordan; Mcguire, Peter; Smith, Andrew

    2014-01-01

    Accurate resuscitation of the critically-ill patient using intravenous fluids and blood products is a challenging, time sensitive task. Ultrasound of the inferior vena cava (IVC) is a non-invasive technique currently used to guide fluid administration, though multiple factors such as variable image quality, time, and operator skill challenge mainstream acceptance. This study represents a first attempt to develop and validate an algorithm capable of automatically tracking and measuring the IVC compared to human operators across a diverse range of image quality. Minimal tracking failures and high levels of agreement between manual and algorithm measurements were demonstrated on good quality videos. Addressing problems such as gaps in the vessel wall and intra-lumen speckle should result in improved performance in average and poor quality videos. Semi-automated measurement of the IVC for the purposes of non-invasive estimation of circulating blood volume poses challenges however is feasible.

  1. Detection and Automated Scoring of Dicentric Chromosomes in Nonstimulated Lymphocyte Prematurely Condensed Chromosomes After Telomere and Centromere Staining

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    M'kacher, Radhia; El Maalouf, Elie; Laboratoire Modélisation Intelligence Processus Systèmes

    Purpose: To combine telomere and centromere (TC) staining of premature chromosome condensation (PCC) fusions to identify dicentrics, centric rings, and acentric chromosomes, making possible the realization of a dose–response curve and automation of the process. Methods and Materials: Blood samples from healthy donors were exposed to {sup 60}Co irradiation at varying doses up to 8 Gy, followed by a repair period of 8 hours. Premature chromosome condensation fusions were carried out, and TC staining using peptide nucleic acid probes was performed. Chromosomal aberration (CA) scoring was carried out manually and automatically using PCC-TCScore software, developed in our laboratory. Results: Wemore » successfully optimized the hybridization conditions and image capture parameters, to increase the sensitivity and effectiveness of CA scoring. Dicentrics, centric rings, and acentric chromosomes were rapidly and accurately detected, leading to a linear-quadratic dose–response curve by manual scoring at up to 8 Gy. Using PCC-TCScore software for automatic scoring, we were able to detect 95% of dicentrics and centric rings. Conclusion: The introduction of TC staining to the PCC fusion technique has made possible the rapid scoring of unstable CAs, including dicentrics, with a level of accuracy and ease not previously possible. This new approach can be used for biological dosimetry in radiation emergency medicine, where the rapid and accurate detection of dicentrics is a high priority using automated scoring. Because there is no culture time, this new approach can also be used for the follow-up of patients treated by genotoxic therapy, creating the possibility to perform the estimation of induced chromosomal aberrations immediately after the blood draw.« less

  2. Hematological alterations and thymic function in newborns of HIV-infected mothers receiving antiretroviral drugs.

    PubMed

    Wongnoi, Rotjanee; Penvieng, Nawaporn; Singboottra, Panthong; Kingkeow, Doungnapa; Oberdorfer, Peninnah; Sirivatanapa, Pannee; Pornprasert, Sakorn

    2013-06-08

    To investigate the effects of antiretroviral (ARV) drugs on hematological parameters and thymic function in HIV-uninfected newborns of HIV-infected mothers. Cross sectional study. Chiang-Mai University Hospital, Chiang-Mai, Thailand. 49 HIV-uninfected and 26 HIV-infected pregnancies. Cord blood samples of newborns from HIV-uninfected and HIV-infected mothers were collected. Hematological parameters were measured using automatic blood cell count. T-cell receptor excision circles (TRECs) levels in cord blood mononuclear cells (CBMCs), CD4+ and CD8+ T-cells were quantified using real-time PCR.. Hemotological parameters and thymic function. Newborn of HIV-infected mother tended to have lower mean levels of hemoglobin than those of HIV-uninfected mother (137 ±22 vs 146 ±17 g/L, P = 0.05). Furthermore, mean of red blood cell (RBC) counts and hematocrit and median of TRECs in CD4+ T-cells in the newborns of the former were significantly lower than those of the latter [3.6 ±0.7 vs 4.8 ±0.6 x 1012 cells/L, P <0.001; 0.40 ±0.07 vs 0.46 ±0.05 L/L, P < 0.001 and 0.53 (IQR: 0.03-5.76) vs 13.20 (IQR: 2.77-27.51) x 10-3 pg/uL, P = 0.02, respectively]. ARV drugs altered hematological parameters and thymic function (TRECs CD4+ T-cells) in HIV-uninfected newborns of HIV-infected mothers.

  3. Automatic cytometric device using multiple wavelength excitations

    NASA Astrophysics Data System (ADS)

    Rongeat, Nelly; Ledroit, Sylvain; Chauvet, Laurence; Cremien, Didier; Urankar, Alexandra; Couderc, Vincent; Nérin, Philippe

    2011-05-01

    Precise identification of eosinophils, basophils, and specific subpopulations of blood cells (B lymphocytes) in an unconventional automatic hematology analyzer is demonstrated. Our specific apparatus mixes two excitation radiations by means of an acousto-optics tunable filter to properly control fluorescence emission of phycoerythrin cyanin 5 (PC5) conjugated to antibodies (anti-CD20 or anti-CRTH2) and Thiazole Orange. This way our analyzer combining techniques of hematology analysis and flow cytometry based on multiple fluorescence detection, drastically improves the signal to noise ratio and decreases the spectral overlaps impact coming from multiple fluorescence emissions.

  4. Manual versus automated blood sampling: impact of repeated blood sampling on stress parameters and behavior in male NMRI mice

    PubMed Central

    Kalliokoski, Otto; Sørensen, Dorte B; Hau, Jann; Abelson, Klas S P

    2014-01-01

    Facial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups. Plasma corticosterone levels of mice subjected to tail blood sampling were also elevated, although less significantly. Mice subjected to automated blood sampling were less affected with regard to the parameters measured, and expressed less anxious behavior. We conclude that repeated blood sampling by automated blood sampling and from the tail vein is less stressful than cheek blood sampling. The choice between automated blood sampling and tail blood sampling should be based on the study requirements, the resources of the laboratory and skills of the staff. PMID:24958546

  5. An Automated Sample Preparation Instrument to Accelerate Positive Blood Cultures Microbial Identification by MALDI-TOF Mass Spectrometry (Vitek®MS).

    PubMed

    Broyer, Patrick; Perrot, Nadine; Rostaing, Hervé; Blaze, Jérome; Pinston, Frederic; Gervasi, Gaspard; Charles, Marie-Hélène; Dachaud, Fabien; Dachaud, Jacques; Moulin, Frederic; Cordier, Sylvain; Dauwalder, Olivier; Meugnier, Hélène; Vandenesch, Francois

    2018-01-01

    Sepsis is the leading cause of death among patients in intensive care units (ICUs) requiring an early diagnosis to introduce efficient therapeutic intervention. Rapid identification (ID) of a causative pathogen is key to guide directed antimicrobial selection and was recently shown to reduce hospitalization length in ICUs. Direct processing of positive blood cultures by MALDI-TOF MS technology is one of the several currently available tools used to generate rapid microbial ID. However, all recently published protocols are still manual and time consuming, requiring dedicated technician availability and specific strategies for batch processing. We present here a new prototype instrument for automated preparation of Vitek ® MS slides directly from positive blood culture broth based on an "all-in-one" extraction strip. This bench top instrument was evaluated on 111 and 22 organisms processed using artificially inoculated blood culture bottles in the BacT/ALERT ® 3D (SA/SN blood culture bottles) or the BacT/ALERT Virtuo TM system (FA/FN Plus bottles), respectively. Overall, this new preparation station provided reliable and accurate Vitek MS species-level identification of 87% (Gram-negative bacteria = 85%, Gram-positive bacteria = 88%, and yeast = 100%) when used with BacT/ALERT ® 3D and of 84% (Gram-negative bacteria = 86%, Gram-positive bacteria = 86%, and yeast = 75%) with Virtuo ® instruments, respectively. The prototype was then evaluated in a clinical microbiology laboratory on 102 clinical blood culture bottles and compared to routine laboratory ID procedures. Overall, the correlation of ID on monomicrobial bottles was 83% (Gram-negative bacteria = 89%, Gram-positive bacteria = 79%, and yeast = 78%), demonstrating roughly equivalent performance between manual and automatized extraction methods. This prototype instrument exhibited a high level of performance regardless of bottle type or BacT/ALERT system. Furthermore, blood culture workflow could potentially be improved by converting direct ID of positive blood cultures from a batch-based to real-time and "on-demand" process.

  6. Set Up of an Automatic Water Quality Sampling System in Irrigation Agriculture

    PubMed Central

    Heinz, Emanuel; Kraft, Philipp; Buchen, Caroline; Frede, Hans-Georg; Aquino, Eugenio; Breuer, Lutz

    2014-01-01

    We have developed a high-resolution automatic sampling system for continuous in situ measurements of stable water isotopic composition and nitrogen solutes along with hydrological information. The system facilitates concurrent monitoring of a large number of water and nutrient fluxes (ground, surface, irrigation and rain water) in irrigated agriculture. For this purpose we couple an automatic sampling system with a Wavelength-Scanned Cavity Ring Down Spectrometry System (WS-CRDS) for stable water isotope analysis (δ2H and δ18O), a reagentless hyperspectral UV photometer (ProPS) for monitoring nitrate content and various water level sensors for hydrometric information. The automatic sampling system consists of different sampling stations equipped with pumps, a switch cabinet for valve and pump control and a computer operating the system. The complete system is operated via internet-based control software, allowing supervision from nearly anywhere. The system is currently set up at the International Rice Research Institute (Los Baños, The Philippines) in a diversified rice growing system to continuously monitor water and nutrient fluxes. Here we present the system's technical set-up and provide initial proof-of-concept with results for the isotopic composition of different water sources and nitrate values from the 2012 dry season. PMID:24366178

  7. Irregular and adaptive sampling for automatic geophysic measure systems

    NASA Astrophysics Data System (ADS)

    Avagnina, Davide; Lo Presti, Letizia; Mulassano, Paolo

    2000-07-01

    In this paper a sampling method, based on an irregular and adaptive strategy, is described. It can be used as automatic guide for rovers designed to explore terrestrial and planetary environments. Starting from the hypothesis that a explorative vehicle is equipped with a payload able to acquire measurements of interesting quantities, the method is able to detect objects of interest from measured points and to realize an adaptive sampling, while badly describing the not interesting background.

  8. The effectiveness of BD Vacutainer® Plus Urinalysis Preservative Tubes in preservation of urine for chemical strip analysis and particle counting

    PubMed Central

    Ekşioğlu, Merve Kaymak; Madenci, Özlem Çakır; Yücel, Nihal; Elçi, Abdullah; Turhan, Bülent; Orhan, Gani; Orçun, Asuman

    2016-01-01

    Introduction The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. Materials and methods 275 pathologic urine specimens were included. Each urine sample was evaluated after 4, 8, 12, 24, and 48 hours of storage in BD Vacutainer® Plus Urinalysis Preservative (BD UAP) tubes and compared with refrigeration at 4 °C. All analyses were peformed on H-800 and FUS-200 automatic modular urine analyzers (Dirui Industry, Changchun, China). The kappa coefficients (κ), false positive (FP) and false negative (FN) rates were evaluated. κ > 0.8 was accepted as good agreement. Results Haemoglobin (Hb), leucocyte esterase (LE), and protein (Pro) analyses should be performed within 4 hours, whereas glucose (Glc) was stable until the end of 48 hours in both storage conditions. Nitrite (Nit) was well preserved in BD UAP tubes for 24 hours but was stable only up to 8 hours at 4 °C. Bilirubin (Bil) had very high FN rates even at 4 hours in both conditions. The particle counting showed high FN rates for white blood cells (WBC) and red blood cells (RBC), whereas squamous epithelial cells (EC) were stable up to 8 hours in both conditions. Conclusions Preanalytical requirements for both urine chemical strip analyses and particle counting in a unique sample were not met in either condition. Thus, the transfer of urine samples for centralization of urinalysis is not yet feasible. PMID:27346967

  9. Investigating the Relationship between Stable Personality Characteristics and Automatic Imitation

    PubMed Central

    Butler, Emily E.; Ward, Robert; Ramsey, Richard

    2015-01-01

    Automatic imitation is a cornerstone of nonverbal communication that fosters rapport between interaction partners. Recent research has suggested that stable dimensions of personality are antecedents to automatic imitation, but the empirical evidence linking imitation with personality traits is restricted to a few studies with modest sample sizes. Additionally, atypical imitation has been documented in autism spectrum disorders and schizophrenia, but the mechanisms underpinning these behavioural profiles remain unclear. Using a larger sample than prior studies (N=243), the current study tested whether performance on a computer-based automatic imitation task could be predicted by personality traits associated with social behaviour (extraversion and agreeableness) and with disorders of social cognition (autistic-like and schizotypal traits). Further personality traits (narcissism and empathy) were assessed in a subsample of participants (N=57). Multiple regression analyses showed that personality measures did not predict automatic imitation. In addition, using a similar analytical approach to prior studies, no differences in imitation performance emerged when only the highest and lowest 20 participants on each trait variable were compared. These data weaken support for the view that stable personality traits are antecedents to automatic imitation and that neural mechanisms thought to support automatic imitation, such as the mirror neuron system, are dysfunctional in autism spectrum disorders or schizophrenia. In sum, the impact that personality variables have on automatic imitation is less universal than initial reports suggest. PMID:26079137

  10. Investigating the Relationship between Stable Personality Characteristics and Automatic Imitation.

    PubMed

    Butler, Emily E; Ward, Robert; Ramsey, Richard

    2015-01-01

    Automatic imitation is a cornerstone of nonverbal communication that fosters rapport between interaction partners. Recent research has suggested that stable dimensions of personality are antecedents to automatic imitation, but the empirical evidence linking imitation with personality traits is restricted to a few studies with modest sample sizes. Additionally, atypical imitation has been documented in autism spectrum disorders and schizophrenia, but the mechanisms underpinning these behavioural profiles remain unclear. Using a larger sample than prior studies (N=243), the current study tested whether performance on a computer-based automatic imitation task could be predicted by personality traits associated with social behaviour (extraversion and agreeableness) and with disorders of social cognition (autistic-like and schizotypal traits). Further personality traits (narcissism and empathy) were assessed in a subsample of participants (N=57). Multiple regression analyses showed that personality measures did not predict automatic imitation. In addition, using a similar analytical approach to prior studies, no differences in imitation performance emerged when only the highest and lowest 20 participants on each trait variable were compared. These data weaken support for the view that stable personality traits are antecedents to automatic imitation and that neural mechanisms thought to support automatic imitation, such as the mirror neuron system, are dysfunctional in autism spectrum disorders or schizophrenia. In sum, the impact that personality variables have on automatic imitation is less universal than initial reports suggest.

  11. Automatic amino acid analyzer

    NASA Technical Reports Server (NTRS)

    Berdahl, B. J.; Carle, G. C.; Oyama, V. I.

    1971-01-01

    Analyzer operates unattended or up to 15 hours. It has an automatic sample injection system and can be programmed. All fluid-flow valve switching is accomplished pneumatically from miniature three-way solenoid pilot valves.

  12. Implementation and validation of a conceptual benchmarking framework for patient blood management.

    PubMed

    Kastner, Peter; Breznik, Nada; Gombotz, Hans; Hofmann, Axel; Schreier, Günter

    2015-01-01

    Public health authorities and healthcare professionals are obliged to ensure high quality health service. Because of the high variability of the utilisation of blood and blood components, benchmarking is indicated in transfusion medicine. Implementation and validation of a benchmarking framework for Patient Blood Management (PBM) based on the report from the second Austrian Benchmark trial. Core modules for automatic report generation have been implemented with KNIME (Konstanz Information Miner) and validated by comparing the output with the results of the second Austrian benchmark trial. Delta analysis shows a deviation <0.1% for 95% (max. 1.4%). The framework provides a reliable tool for PBM benchmarking. The next step is technical integration with hospital information systems.

  13. A comparison of four different blood gas analysers.

    PubMed

    Kofstad, J

    1981-06-01

    Four automatic blood gas analysers from four different manufactures were evaluated and compared. The measurements were performed on blood representing respiratory acidosis and hypoxemia, normal conditions, and respiratory alkalosis and hyperoxemia. On each level nine complete runs were carried out, each run consisting of six replicates of each parameter (pH, Pco2 and Po2) on each instrument (six rounds). Only the directly measured parameters (pH, Pco2, Po2) were compared. The main conclusion is that the four instruments can be used alternatively, and that the differences between the values measured by the four instruments are of little clinical significance.

  14. [Optimization of blood gas analysis in intensive care units : Reduction of preanalytical errors and improvement of workflow].

    PubMed

    Kieninger, M; Zech, N; Mulzer, Y; Bele, S; Seemann, M; Künzig, H; Schneiker, A; Gruber, M

    2015-05-01

    Point of care testing with blood gas analysis (BGA) is an important factor for intensive care medicine. Continuous efforts to optimize workflow, improve safety for the staff and avoid preanalytical mistakes are important and should reflect quality management standards. In a prospective observational study it was investigated whether the implementation of a new system for BGA using labeled syringes and automated processing of the specimens leads to improvements compared to the previously used procedure. In a 4-week test period the time until receiving the final results of the BGA with the standard method used in the clinical routine (control group) was compared to the results in a second 4-week test period using the new labeled syringes and automated processing of the specimens (intervention group). In addition, preanalytical mistakes with both systems were checked during routine daily use. Finally, it was investigated whether a delay of 10 min between taking and analyzing the blood samples alters the results of the BGA. Preanalytical errors were frequently observed in the control group where non-deaerated samples were recorded in 87.3 % but in the intervention group almost all samples (98.9 %) were correctly deaerated. Insufficient homogenization due to omission of manual pivoting was seen in 83.2 % in the control group and in 89.9 % in the intervention group; however, in the intervention group the samples were homogenized automatically during the further analytical process. Although a survey among the staff revealed a high acceptance of the new system and a subjective improvement of workflow, a measurable gain in time after conversion to the new procedure could not be seen. The mean time needed for a complete analysis process until receiving the final results was 244 s in the intervention group and 201 s in the control group. A 10-min delay between taking and analyzing the blood samples led to a significant and clinically relevant elevation of the values for partial pressure of oxygen (pO2) in both groups compared to the results when analyzing the samples immediately (118.4 vs. 148.6 mmHg in the control group and 115.3 vs. 123.7 mmHg in the intervention group). When using standard syringes the partial pressure of carbon dioxide (pCO2) was significantly lower (40.5 vs. 38.3 mmHg) whereas no alterations were seen when using the labeled syringes. The implementation of a new BGA system with labeled syringes and automated processing of the specimens was possible without any difficulties under daily clinical routine conditions in this 10-bed intensive care unit (ICU). A gain of time could not be measured but a reduction in preanalytical errors using the labeled syringes with automated processing was found. Delayed analysis of blood samples can lead to significant changes in pO2 and pCO2 depending on the type of syringe used.

  15. [Study on the automatic parameters identification of water pipe network model].

    PubMed

    Jia, Hai-Feng; Zhao, Qi-Feng

    2010-01-01

    Based on the problems analysis on development and application of water pipe network model, the model parameters automatic identification is regarded as a kernel bottleneck of model's application in water supply enterprise. The methodology of water pipe network model parameters automatic identification based on GIS and SCADA database is proposed. Then the kernel algorithm of model parameters automatic identification is studied, RSA (Regionalized Sensitivity Analysis) is used for automatic recognition of sensitive parameters, and MCS (Monte-Carlo Sampling) is used for automatic identification of parameters, the detail technical route based on RSA and MCS is presented. The module of water pipe network model parameters automatic identification is developed. At last, selected a typical water pipe network as a case, the case study on water pipe network model parameters automatic identification is conducted and the satisfied results are achieved.

  16. Pharmaceutical dust exposure at pharmacies using automatic dispensing machines: a preliminary study.

    PubMed

    Fent, Kenneth W; Durgam, Srinivas; Mueller, Charles

    2014-01-01

    Automatic dispensing machines (ADMs) used in pharmacies concentrate and dispense large volumes of pharmaceuticals, including uncoated tablets that can shed dust. We evaluated 43 employees' exposures to pharmaceutical dust at three pharmacies where ADMs were used. We used an optical particle counter to identify tasks that generated pharmaceutical dust. We collected 72 inhalable dust air samples in or near the employees' breathing zones. In addition to gravimetric analysis, our contract laboratory used internal methods involving liquid chromatography to analyze these samples for active pharmaceutical ingredients (APIs) and/or lactose, an inactive filler in tablets. We had to choose samples for these additional analyses because many methods used different extraction solvents. We selected 57 samples for analysis of lactose. We used real-time particle monitoring results, observations, and information from employees on the dustiness of pharmaceuticals to select 28 samples (including 13 samples that were analyzed for lactose) for analysis of specific APIs. Pharmaceutical dust was generated during a variety of tasks like emptying and refilling of ADM canisters. Using compressed air to clean canisters and manual count machines produced the overall highest peak number concentrations (19,000-580,000 particles/L) of smallest particles (count median aerodynamic diameter ≤ 2 μm). Employees who refilled, cleaned, or repaired ADM canisters, or hand filled prescriptions were exposed to higher median air concentrations of lactose (5.0-12 μg/m(3)) than employees who did other jobs (0.04-1.3 μg/m(3)), such as administrative/office work, labeling/packaging, and verifying prescriptions. We detected 10 APIs in air, including lisinopril, a drug prescribed for high blood pressure, levothyroxine, a drug prescribed for hypothyroidism, and methotrexate, a hazardous drug prescribed for cancer and other disorders. Three air concentrations of lisinopril (1.8-2.7 μg/m(3)) exceeded the lower bound of the manufacturer's hazard control band (1-10 μg/m(3)). All other API air concentrations were below applicable occupational exposure limits. Our findings indicate that some pharmacy employees are exposed to multiple APIs and that measures are needed to control those exposures.

  17. Segmentation of left atrial intracardiac ultrasound images for image guided cardiac ablation therapy

    NASA Astrophysics Data System (ADS)

    Rettmann, M. E.; Stephens, T.; Holmes, D. R.; Linte, C.; Packer, D. L.; Robb, R. A.

    2013-03-01

    Intracardiac echocardiography (ICE), a technique in which structures of the heart are imaged using a catheter navigated inside the cardiac chambers, is an important imaging technique for guidance in cardiac ablation therapy. Automatic segmentation of these images is valuable for guidance and targeting of treatment sites. In this paper, we describe an approach to segment ICE images by generating an empirical model of blood pool and tissue intensities. Normal, Weibull, Gamma, and Generalized Extreme Value (GEV) distributions are fit to histograms of tissue and blood pool pixels from a series of ICE scans. A total of 40 images from 4 separate studies were evaluated. The model was trained and tested using two approaches. In the first approach, the model was trained on all images from 3 studies and subsequently tested on the 40 images from the 4th study. This procedure was repeated 4 times using a leave-one-out strategy. This is termed the between-subjects approach. In the second approach, the model was trained on 10 randomly selected images from a single study and tested on the remaining 30 images in that study. This is termed the within-subjects approach. For both approaches, the model was used to automatically segment ICE images into blood and tissue regions. Each pixel is classified using the Generalized Liklihood Ratio Test across neighborhood sizes ranging from 1 to 49. Automatic segmentation results were compared against manual segmentations for all images. In the between-subjects approach, the GEV distribution using a neighborhood size of 17 was found to be the most accurate with a misclassification rate of approximately 17%. In the within-subjects approach, the GEV distribution using a neighborhood size of 19 was found to be the most accurate with a misclassification rate of approximately 15%. As expected, the majority of misclassified pixels were located near the boundaries between tissue and blood pool regions for both methods.

  18. An Automatic Occlusion Device for Remote Control of Tumor Tissue Ischemia

    PubMed Central

    El-Dahdah, Hamid; Wang, Bei; He, Guanglong; Xu, Ronald X.

    2015-01-01

    We developed an automatic occlusion device for remote control of tumor tissue ischemia. The device consists of a flexible cannula encasing a shape memory alloy wire with its distal end connected to surgical suture. Regional tissue occlusion was tested on both the benchtop and the animal models. In the benchtop test, the occlusion device introduced quantitative and reproducible changes of blood flow in a tissue simulating phantom embedding a vessel simulator. In the animal test, the device generated a cyclic pattern of reversible ischemia in the right hinder leg tissue of a black male C57BL/6 mouse. We also developed a multimodal detector that integrates near infrared spectroscopy and electron paramagnetic resonance spectroscopy for continuous monitoring of tumor tissue oxygenation, blood content, and oxygen tension changes. The multimodal detector was tested on a cancer xenograft nude mouse undergoing reversible tumor ischemia. The automatic occlusion device and the multi-modal detector can be potentially integrated for closed-loop feedback control of tumor tissue ischemia. Such an integrated occlusion device may be used in multiple clinical applications such as regional hypoperfusion control in tumor resection surgeries and thermal ablation processes. In addition, the proposed occlusion device can also be used as a research tool to understand tumor oxygen transport and hemodynamic characteristics. PMID:20082532

  19. Exposure to violent video games increases automatic aggressiveness.

    PubMed

    Uhlmann, Eric; Swanson, Jane

    2004-02-01

    The effects of exposure to violent video games on automatic associations with the self were investigated in a sample of 121 students. Playing the violent video game Doom led participants to associate themselves with aggressive traits and actions on the Implicit Association Test. In addition, self-reported prior exposure to violent video games predicted automatic aggressive self-concept, above and beyond self-reported aggression. Results suggest that playing violent video games can lead to the automatic learning of aggressive self-views.

  20. [The design and applications of a non-invasive intelligent detector for cardiovascular functions].

    PubMed

    Li, Feng; Xing, Wu; Chen, Ming-zhi; Shang, Huai

    2006-05-01

    An apparatus based on a high sensitive sensor which detects cardiovascular functions is introduced in this paper. Some intelligent detecting technologies, such as syntactic pattern recognition and a medical expert system are used in this detector. Its embedded single-chip microcomputer processes and analyzes pulse signals for gaining automatically the parameters about heart, blood vessel and blood etc., so as to get the health evaluation, correct medical diagnosis and prediction of cardiovascular diseases.

  1. Detection of β-Thalassemia Carriers by Red Cell Parameters Obtained from Automatic Counters using Mathematical Formulas

    PubMed Central

    Roth, Idit Lachover; Lachover, Boaz; Koren, Guy; Levin, Carina; Zalman, Luci; Koren, Ariel

    2018-01-01

    Background β-thalassemia major is a severe disease with high morbidity. The world prevalence of carriers is around 1.5–7%. The present study aimed to find a reliable formula for detecting β-thalassemia carriers using an extensive database of more than 22,000 samples obtained from a homogeneous population of childbearing age women with 3161 (13.6%) of β-thalassemia carriers and to check previously published formulas. Methods We applied a mathematical method based on the support vector machine (SVM) algorithm in the search for a reliable formula that can differentiate between thalassemia carriers and non-carriers, including normal counts or counts suspected to belong to iron-deficient women. Results Shine’s formula and our SVM formula showed >98% sensitivity and >99.77% negative predictive value (NPV). All other published formulas gave inferior results. Conclusions We found a reliable formula that can be incorporated into any automatic blood counter to alert health providers to the possibility of a woman being a β-thalassemia carrier. A further simple hemoglobin characterization by HPLC analysis should be performed to confirm the diagnosis, and subsequent family studies should be carried out. Our SVM formula is currently limited to women of fertility age until further analysis in other groups can be performed. PMID:29326805

  2. Nested Machine Learning Facilitates Increased Sequence Content for Large-Scale Automated High Resolution Melt Genotyping

    PubMed Central

    Fraley, Stephanie I.; Athamanolap, Pornpat; Masek, Billie J.; Hardick, Justin; Carroll, Karen C.; Hsieh, Yu-Hsiang; Rothman, Richard E.; Gaydos, Charlotte A.; Wang, Tza-Huei; Yang, Samuel

    2016-01-01

    High Resolution Melt (HRM) is a versatile and rapid post-PCR DNA analysis technique primarily used to differentiate sequence variants among only a few short amplicons. We recently developed a one-vs-one support vector machine algorithm (OVO SVM) that enables the use of HRM for identifying numerous short amplicon sequences automatically and reliably. Herein, we set out to maximize the discriminating power of HRM + SVM for a single genetic locus by testing longer amplicons harboring significantly more sequence information. Using universal primers that amplify the hypervariable bacterial 16 S rRNA gene as a model system, we found that long amplicons yield more complex HRM curve shapes. We developed a novel nested OVO SVM approach to take advantage of this feature and achieved 100% accuracy in the identification of 37 clinically relevant bacteria in Leave-One-Out-Cross-Validation. A subset of organisms were independently tested. Those from pure culture were identified with high accuracy, while those tested directly from clinical blood bottles displayed more technical variability and reduced accuracy. Our findings demonstrate that long sequences can be accurately and automatically profiled by HRM with a novel nested SVM approach and suggest that clinical sample testing is feasible with further optimization. PMID:26778280

  3. An automated retinal imaging method for the early diagnosis of diabetic retinopathy.

    PubMed

    Franklin, S Wilfred; Rajan, S Edward

    2013-01-01

    Diabetic retinopathy is a microvascular complication of long-term diabetes and is the major cause for eyesight loss due to changes in blood vessels of the retina. Major vision loss due to diabetic retinopathy is highly preventable with regular screening and timely intervention at the earlier stages. Retinal blood vessel segmentation methods help to identify the successive stages of such sight threatening diseases like diabetes. To develop and test a novel retinal imaging method which segments the blood vessels automatically from retinal images, which helps the ophthalmologists in the diagnosis and follow-up of diabetic retinopathy. This method segments each image pixel as vessel or nonvessel, which in turn, used for automatic recognition of the vasculature in retinal images. Retinal blood vessels were identified by means of a multilayer perceptron neural network, for which the inputs were derived from the Gabor and moment invariants-based features. Back propagation algorithm, which provides an efficient technique to change the weights in a feed forward network, is utilized in our method. Quantitative results of sensitivity, specificity and predictive values were obtained in our method and the measured accuracy of our segmentation algorithm was 95.3%, which is better than that presented by state-of-the-art approaches. The evaluation procedure used and the demonstrated effectiveness of our automated retinal imaging method proves itself as the most powerful tool to diagnose diabetic retinopathy in the earlier stages.

  4. Efficient Word Reading: Automaticity of Print-Related Skills Indexed by Rapid Automatized Naming through Cusp-Catastrophe Modeling

    ERIC Educational Resources Information Center

    Sideridis, Georgios D.; Simos, Panagiotis; Mouzaki, Angeliki; Stamovlasis, Dimitrios

    2016-01-01

    The study explored the moderating role of rapid automatized naming (RAN) in reading achievement through a cusp-catastrophe model grounded on nonlinear dynamic systems theory. Data were obtained from a community sample of 496 second through fourth graders who were followed longitudinally over 2 years and split into 2 random subsamples (validation…

  5. Automatic frequency control for FM transmitter

    NASA Technical Reports Server (NTRS)

    Honnell, M. A. (Inventor)

    1974-01-01

    An automatic frequency control circuit for an FM television transmitter is described. The frequency of the transmitter is sampled during what is termed the back porch portion of the horizontal synchronizing pulse which occurs during the retrace interval, the frequency sample compared with the frequency of a reference oscillator, and a correction applied to the frequency of the transmitter during this portion of the retrace interval.

  6. The dynamics of rupture in porous media

    NASA Astrophysics Data System (ADS)

    Stopiński, Wojciech; Ponomaryov, Aleksandr V.; Loś, Vladimir

    1991-05-01

    This paper presents a laboratory investigation of electric resistivity parameter for samples subject to loading in automatic press of “INOVA” type. The procedure of automatic quasi-continuous measurements of resistivity is briefly outlined. The distribution of mini-electrodes within the sample is described. Also shown is the manner in which reliability can be improved by increasing the repetition of resistivity measurements (every 7 16 s).

  7. 10 CFR 431.135 - Units to be tested.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... EQUIPMENT Automatic Commercial Ice Makers Test Procedures § 431.135 Units to be tested. For each basic model of automatic commercial ice maker selected for testing, a sample of sufficient size shall be selected...

  8. AUTOMATIC MASS SPECTROMETER

    DOEpatents

    Hanson, M.L.; Tabor, C.D. Jr.

    1961-12-01

    A mass spectrometer for analyzing the components of a gas is designed which is capable of continuous automatic operation such as analysis of samples of process gas from a continuous production system where the gas content may be changing. (AEC)

  9. Combinatorial Screening Of Inorganic And Organometallic Materials

    DOEpatents

    Li, Yi , Li, Jing , Britton, Ted W.

    2002-06-25

    A method for differentiating and enumerating nucleated red blood cells in a blood sample is described. The method includes the steps of lysing red blood cells of a blood sample with a lytic reagent, measuring nucleated blood cells by DC impedance measurement in a non-focused flow aperture, differentiating nucleated red blood cells from other cell types, and reporting nucleated red blood cells in the blood sample. The method further includes subtracting nucleated red blood cells and other interference materials from the count of remaining blood cells, and reporting a corrected white blood cell count of the blood sample. Additionally, the method further includes measuring spectrophotometric absorbance of the sample mixture at a predetermined wavelength of a hemoglobin chromogen formed upon lysing the blood sample, and reporting hemoglobin concentration of the blood sample.

  10. Parent-Child Interaction Using a Mobile and Wireless System for Blood Glucose Monitoring

    PubMed Central

    Årsand, Eirik; Walseth, Ole Anders; Andersson, Niklas; Jenssen, Martin; Taylor, Ted

    2005-01-01

    Background Children with type 1 diabetes and their parents face rigorous procedures for blood glucose monitoring and regulation. Mobile telecommunication systems show potential as an aid for families’ self-management of diabetes. Objective A prototype designed to automatically transfer readings from a child’s blood glucose monitor to their parent’s mobile phone was tested. In this formative stage of development, we sought insights into the appropriateness of the concept, feasibility of use, and ideas for further development and research. Methods During four months, a self-selected sample of 15 children (aged 9 to 15 years) with type 1 diabetes and their parents (n = 30) used the prototype approximately three times daily. Parent and child experiences were collected through questionnaires and through interviews with 9 of the parents. Results System use was easily integrated into everyday life, and parents valued the sense of reassurance offered by the system. Parents’ ongoing struggle to balance control of their children with allowing independence was evident. For children who measured regularly, use appeared to reduce parental intrusions. For those who measured irregularly, however, parental reminders (eg, “nagging”) appeared to increase. Although increased reminders could be considered a positive outcome, they can potentially increase parent-child conflict and thus also undermine proper metabolic control. Parents felt that system appropriateness tapered off with the onset of adolescence, partly due to a potential sense of surveillance from the child’s perspective that could fuel oppositional behavior. Parental suggestions for further developments included similar alerts of irregular insulin dosages and automatically generated dietary and insulin dosage advice. Conclusions User enthusiasm suggests that such systems might find a consumer market regardless of whether or not they ultimately improve health outcomes. Thus, more rigorous studies are warranted to inform guidelines for appropriate use. Potentially fruitful approaches include integrating such systems with theory-based parenting interventions and approaches that can aid in interpreting and responding to experiences of surveillance, virtual presence, and balances of power in e-mediated relationships. PMID:16403721

  11. Classification tree for the assessment of sedentary lifestyle among hypertensive.

    PubMed

    Castelo Guedes Martins, Larissa; Venícios de Oliveira Lopes, Marcos; Gomes Guedes, Nirla; Paixão de Menezes, Angélica; de Oliveira Farias, Odaleia; Alves Dos Santos, Naftale

    2016-04-01

    To develop a classification tree of clinical indicators for the correct prediction of the nursing diagnosis "Sedentary lifestyle" (SL) in people with high blood pressure (HTN). A cross-sectional study conducted in an outpatient care center specializing in high blood pressure and Mellitus diabetes located in northeastern Brazil. The sample consisted of 285 people between 19 and 59 years old diagnosed with high blood pressure and was applied an interview and physical examination, obtaining socio-demographic information, related factors and signs and symptoms that made the defining characteristics for the diagnosis under study. The tree was generated using the CHAID algorithm (Chi-square Automatic Interaction Detection). The construction of the decision tree allowed establishing the interactions between clinical indicators that facilitate a probabilistic analysis of multiple situations allowing quantify the probability of an individual presenting a sedentary lifestyle. The tree included the clinical indicator Choose daily routine without exercise as the first node. People with this indicator showed a probability of 0.88 of presenting the SL. The second node was composed of the indicator Does not perform physical activity during leisure, with 0.99 probability of presenting the SL with these two indicators. The predictive capacity of the tree was established at 69.5%. Decision trees help nurses who care HTN people in decision-making in assessing the characteristics that increase the probability of SL nursing diagnosis, optimizing the time for diagnostic inference.

  12. Holoentropy enabled-decision tree for automatic classification of diabetic retinopathy using retinal fundus images.

    PubMed

    Mane, Vijay Mahadeo; Jadhav, D V

    2017-05-24

    Diabetic retinopathy (DR) is the most common diabetic eye disease. Doctors are using various test methods to detect DR. But, the availability of test methods and requirements of domain experts pose a new challenge in the automatic detection of DR. In order to fulfill this objective, a variety of algorithms has been developed in the literature. In this paper, we propose a system consisting of a novel sparking process and a holoentropy-based decision tree for automatic classification of DR images to further improve the effectiveness. The sparking process algorithm is developed for automatic segmentation of blood vessels through the estimation of optimal threshold. The holoentropy enabled decision tree is newly developed for automatic classification of retinal images into normal or abnormal using hybrid features which preserve the disease-level patterns even more than the signal level of the feature. The effectiveness of the proposed system is analyzed using standard fundus image databases DIARETDB0 and DIARETDB1 for sensitivity, specificity and accuracy. The proposed system yields sensitivity, specificity and accuracy values of 96.72%, 97.01% and 96.45%, respectively. The experimental result reveals that the proposed technique outperforms the existing algorithms.

  13. Automatic Recognition of Acute Myelogenous Leukemia in Blood Microscopic Images Using K-means Clustering and Support Vector Machine.

    PubMed

    Kazemi, Fatemeh; Najafabadi, Tooraj Abbasian; Araabi, Babak Nadjar

    2016-01-01

    Acute myelogenous leukemia (AML) is a subtype of acute leukemia, which is characterized by the accumulation of myeloid blasts in the bone marrow. Careful microscopic examination of stained blood smear or bone marrow aspirate is still the most significant diagnostic methodology for initial AML screening and considered as the first step toward diagnosis. It is time-consuming and due to the elusive nature of the signs and symptoms of AML; wrong diagnosis may occur by pathologists. Therefore, the need for automation of leukemia detection has arisen. In this paper, an automatic technique for identification and detection of AML and its prevalent subtypes, i.e., M2-M5 is presented. At first, microscopic images are acquired from blood smears of patients with AML and normal cases. After applying image preprocessing, color segmentation strategy is applied for segmenting white blood cells from other blood components and then discriminative features, i.e., irregularity, nucleus-cytoplasm ratio, Hausdorff dimension, shape, color, and texture features are extracted from the entire nucleus in the whole images containing multiple nuclei. Images are classified to cancerous and noncancerous images by binary support vector machine (SVM) classifier with 10-fold cross validation technique. Classifier performance is evaluated by three parameters, i.e., sensitivity, specificity, and accuracy. Cancerous images are also classified into their prevalent subtypes by multi-SVM classifier. The results show that the proposed algorithm has achieved an acceptable performance for diagnosis of AML and its common subtypes. Therefore, it can be used as an assistant diagnostic tool for pathologists.

  14. Computer-aided diagnostic detection system of venous beading in retinal images

    NASA Astrophysics Data System (ADS)

    Yang, Ching-Wen; Ma, DyeJyun; Chao, ShuennChing; Wang, ChuinMu; Wen, Chia-Hsien; Lo, ChienShun; Chung, Pau-Choo; Chang, Chein-I.

    2000-05-01

    The detection of venous beading in retinal images provides an early sign of diabetic retinopathy and plays an important role as a preprocessing step in diagnosing ocular diseases. We present a computer-aided diagnostic system to automatically detect venous beading of blood vessels. It comprises of two modules, referred to as the blood vessel extraction module and the venus beading detection module. The former uses a bell-shaped Gaussian kernel with 12 azimuths to extract blood vessels while the latter applies a neural network-based shape cognitron to detect venous beading among the extracted blood vessels for diagnosis. Both modules are fully computer-automated. To evaluate the proposed system, 61 retinal images (32 beaded and 29 normal images) are used for performance evaluation.

  15. Blood Pressure Checker

    NASA Technical Reports Server (NTRS)

    1979-01-01

    An estimated 30 million people in the United States have high blood pressure, or hypertension. But a great many of them are unaware of it because hypertension, in its initial stages, displays no symptoms. Thus, the simply-operated blood pressure checking devices now widely located in public places are useful health aids. The one pictured above, called -Medimax 30, is a direct spinoff from NASA technology developed to monitor astronauts in space. For manned space flights, NASA wanted a compact, highly-reliable, extremely accurate method of checking astronauts' blood pressure without the need for a physician's interpretive skill. NASA's Johnson Space Center and Technology, Inc., a contractor, developed an electronic sound processor that automatically analyzes blood flow sounds to get both systolic (contracting arteries) and diastolic (expanding arteries) blood pressure measurements. NASA granted a patent license for this technology to Advanced Life Sciences, Inc., New York City, manufacturers of Medimax 30.

  16. Assessing Hemorrhage Severity with Continuous Automatic Heart-Rate-Complexity Monitoring in Swine

    DTIC Science & Technology

    2014-12-02

    resuscitative interven- tions, HRC metrics individually were associated with death: SampEn p=0.0002, area under the curve ( AUC ) =.88; MSE p=0.002, AUC =.83...Spontaneously breathing consciously sedated swine were shed 65% of blood volume over 1 hour, then were randomized to 3 groups: control (C, n=7...transfusion of shed blood (TSB, n=7); or endovascular balloon occlusion of the aorta (REBOA) (Pryor Medical, Arvada, CO) for up to 60 minutes followed

  17. Feasibility Assessment of a Structurally Closable, Automatable Technique, for the Deglycerolization of Frozen RBC (Human). Phase 2

    DTIC Science & Technology

    1996-04-01

    to biocompatible levels. associated with collection, testing , inventory and trans- Thawed cells are processed in order to reduce both the glycerol... tested . The instrument is capable of prediluting and washing up to two units of blood per tube set. Our results show that when the performance of our...concentration of glycerol has to be reduced to biocompatible levels (from 1.57 M to less than 0.1 M). Freezing and thawing red blood cells leads to

  18. Automatic Residential/Commercial Classification of Parcels with Solar Panel Detections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morton, April M; Omitaomu, Olufemi A; Kotikot, Susan

    A computational method to automatically detect solar panels on rooftops to aid policy and financial assessment of solar distributed generation. The code automatically classifies parcels containing solar panels in the U.S. as residential or commercial. The code allows the user to specify an input dataset containing parcels and detected solar panels, and then uses information about the parcels and solar panels to automatically classify the rooftops as residential or commercial using machine learning techniques. The zip file containing the code includes sample input and output datasets for the Boston and DC areas.

  19. Basic forest cover mapping using digitized remote sensor data and automated data processing techniques

    NASA Technical Reports Server (NTRS)

    Coggeshall, M. E.; Hoffer, R. M.

    1973-01-01

    Remote sensing equipment and automatic data processing techniques were employed as aids in the institution of improved forest resource management methods. On the basis of automatically calculated statistics derived from manually selected training samples, the feature selection processor of LARSYS selected, upon consideration of various groups of the four available spectral regions, a series of channel combinations whose automatic classification performances (for six cover types, including both deciduous and coniferous forest) were tested, analyzed, and further compared with automatic classification results obtained from digitized color infrared photography.

  20. The relationship between parents' and children's automatic thoughts in a college student sample.

    PubMed

    Donnelly, Reesa; Renk, Kimberly; Sims, Valerie K; McGuire, Jack

    2011-04-01

    Research demonstrates the importance of early social interactions in the development of schemas and automatic thoughts. It does not appear, however, that the existing research examines intergenerational correlations in automatic thoughts. As a result, this study explores the relationship between the automatic thoughts of parents and those of their college-age children in a sample of 252 college students and their mothers and fathers. Results of this study suggest that there are significant relationships between parents' and college students' positive automatic thoughts. Different trends by gender also are noted in the relationships among variables for male and female college students with their mothers and fathers. Further, mothers' positive ATs predicted the positive ATs of their college students, with mothers' ratings of their own communication with their college students mediating partially this relationship. Finally, college students' anxiety and self-esteem is predicted significantly by their mothers' anxiety and self-esteem (respectively) as well as their own positive and negative ATs. These findings suggest the possibility that ATs play a role in the intergenerational transmission of certain domains of psychological functioning.

  1. Progressive sampling-based Bayesian optimization for efficient and automatic machine learning model selection.

    PubMed

    Zeng, Xueqiang; Luo, Gang

    2017-12-01

    Machine learning is broadly used for clinical data analysis. Before training a model, a machine learning algorithm must be selected. Also, the values of one or more model parameters termed hyper-parameters must be set. Selecting algorithms and hyper-parameter values requires advanced machine learning knowledge and many labor-intensive manual iterations. To lower the bar to machine learning, miscellaneous automatic selection methods for algorithms and/or hyper-parameter values have been proposed. Existing automatic selection methods are inefficient on large data sets. This poses a challenge for using machine learning in the clinical big data era. To address the challenge, this paper presents progressive sampling-based Bayesian optimization, an efficient and automatic selection method for both algorithms and hyper-parameter values. We report an implementation of the method. We show that compared to a state of the art automatic selection method, our method can significantly reduce search time, classification error rate, and standard deviation of error rate due to randomization. This is major progress towards enabling fast turnaround in identifying high-quality solutions required by many machine learning-based clinical data analysis tasks.

  2. Apparatus for microbiological sampling. [including automatic swabbing

    NASA Technical Reports Server (NTRS)

    Wilkins, J. R.; Mills, S. M. (Inventor)

    1974-01-01

    An automatic apparatus is described for microbiologically sampling surface using a cotton swab which eliminates human error. The apparatus includes a self-powered transport device, such as a motor-driven wheeled cart, which mounts a swabbing motor drive for a crank arm which supports a swab in the free end thereof. The swabbing motor is pivotably mounted and an actuator rod movable responsive to the cart traveling a predetermined distance provides lifting of the swab from the surface being sampled and reversal of the direction of travel of the cart.

  3. A semi-automatic method for extracting thin line structures in images as rooted tree network

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brazzini, Jacopo; Dillard, Scott; Soille, Pierre

    2010-01-01

    This paper addresses the problem of semi-automatic extraction of line networks in digital images - e.g., road or hydrographic networks in satellite images, blood vessels in medical images, robust. For that purpose, we improve a generic method derived from morphological and hydrological concepts and consisting in minimum cost path estimation and flow simulation. While this approach fully exploits the local contrast and shape of the network, as well as its arborescent nature, we further incorporate local directional information about the structures in the image. Namely, an appropriate anisotropic metric is designed by using both the characteristic features of the targetmore » network and the eigen-decomposition of the gradient structure tensor of the image. Following, the geodesic propagation from a given seed with this metric is combined with hydrological operators for overland flow simulation to extract the line network. The algorithm is demonstrated for the extraction of blood vessels in a retina image and of a river network in a satellite image.« less

  4. Can Wireless Technology Enable New Diabetes Management Tools?

    PubMed Central

    Hedtke, Paul A.

    2008-01-01

    Mobile computing and communications technology embodied in the modern cell phone device can be employed to improve the lives of diabetes patients by giving them better tools for self-management. Several companies are working on the development of diabetes management tools that leverage the ubiquitous cell phone to bring self-management tools to the hand of the diabetes patient. Integration of blood glucose monitoring (BGM) technology with the cell phone platform adds a level of convenience for the person with diabetes, but, more importantly, allows BGM data to be automatically captured, logged, and processed in near real time in order to provide the diabetes patient with assistance in managing their blood glucose levels. Other automatic measurements can estimate physical activity, and information regarding medication events and food intake can be captured and analyzed in order to provide the diabetes patient with continual assistance in managing their therapy and behaviors in order to improve glycemic control. The path to realization of such solutions is not, however, without obstacles. PMID:19885187

  5. Can wireless technology enable new diabetes management tools?

    PubMed

    Hedtke, Paul A

    2008-01-01

    Mobile computing and communications technology embodied in the modern cell phone device can be employed to improve the lives of diabetes patients by giving them better tools for self-management. Several companies are working on the development of diabetes management tools that leverage the ubiquitous cell phone to bring self-management tools to the hand of the diabetes patient. Integration of blood glucose monitoring (BGM) technology with the cell phone platform adds a level of convenience for the person with diabetes, but, more importantly, allows BGM data to be automatically captured, logged, and processed in near real time in order to provide the diabetes patient with assistance in managing their blood glucose levels. Other automatic measurements can estimate physical activity, and information regarding medication events and food intake can be captured and analyzed in order to provide the diabetes patient with continual assistance in managing their therapy and behaviors in order to improve glycemic control. The path to realization of such solutions is not, however, without obstacles.

  6. Correlation between automatic detection of malaria on thin film and experts' parasitaemia scores

    NASA Astrophysics Data System (ADS)

    Sunarko, Budi; Williams, Simon; Prescott, William R.; Byker, Scott M.; Bottema, Murk J.

    2017-03-01

    An algorithm was developed to diagnose the presence of malaria and to estimate the depth of infection by automatically counting individual normal and infected erythrocytes in images of thin blood smears. During the training stage, the parameters of the algorithm were optimized to maximize correlation with estimates of parasitaemia from expert human observers. The correlation was tested on a set of 1590 images from seven thin film blood smears. The correlation between the results from the algorithm and expert human readers was r = 0.836. Results indicate that reliable estimates of parasitaemia may be achieved by computational image analysis methods applied to images of thin film smears. Meanwhile, compared to biological experiments, the algorithm fitted well the three high parasitaemia slides and a mid-level parasitaemia slide, and overestimated the three low parasitaemia slides. To improve the parasitaemia estimation, the sources of the overestimation were identified. Emphasis is laid on the importance of further research in order to identify parasites independently of their erythrocyte hosts

  7. Automated mass spectrometer analysis system

    NASA Technical Reports Server (NTRS)

    Giffin, Charles E. (Inventor); Kuppermann, Aron (Inventor); Dreyer, William J. (Inventor); Boettger, Heinz G. (Inventor)

    1982-01-01

    An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatilizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vilicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

  8. Automated mass spectrometer analysis system

    NASA Technical Reports Server (NTRS)

    Boettger, Heinz G. (Inventor); Giffin, Charles E. (Inventor); Dreyer, William J. (Inventor); Kuppermann, Aron (Inventor)

    1978-01-01

    An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vidicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

  9. Evaluation of Automatic Vehicle Location accuracy

    DOT National Transportation Integrated Search

    1999-01-01

    This study assesses the accuracy of the Automatic Vehicle Location (AVL) data provided for the buses of the Ann Arbor Transportation Authority with Global Positioning System (GPS) technology. In a sample of eighty-nine bus trips two kinds of accuracy...

  10. Automatic Bayes Factors for Testing Equality- and Inequality-Constrained Hypotheses on Variances.

    PubMed

    Böing-Messing, Florian; Mulder, Joris

    2018-05-03

    In comparing characteristics of independent populations, researchers frequently expect a certain structure of the population variances. These expectations can be formulated as hypotheses with equality and/or inequality constraints on the variances. In this article, we consider the Bayes factor for testing such (in)equality-constrained hypotheses on variances. Application of Bayes factors requires specification of a prior under every hypothesis to be tested. However, specifying subjective priors for variances based on prior information is a difficult task. We therefore consider so-called automatic or default Bayes factors. These methods avoid the need for the user to specify priors by using information from the sample data. We present three automatic Bayes factors for testing variances. The first is a Bayes factor with equal priors on all variances, where the priors are specified automatically using a small share of the information in the sample data. The second is the fractional Bayes factor, where a fraction of the likelihood is used for automatic prior specification. The third is an adjustment of the fractional Bayes factor such that the parsimony of inequality-constrained hypotheses is properly taken into account. The Bayes factors are evaluated by investigating different properties such as information consistency and large sample consistency. Based on this evaluation, it is concluded that the adjusted fractional Bayes factor is generally recommendable for testing equality- and inequality-constrained hypotheses on variances.

  11. An automated atmospheric sampling system operating on 747 airliners

    NASA Technical Reports Server (NTRS)

    Perkins, P. J.; Gustafsson, U. R. C.

    1976-01-01

    An air sampling system that automatically measures the temporal and spatial distribution of particulate and gaseous constituents of the atmosphere is collecting data on commercial air routes covering the world. Measurements are made in the upper troposphere and lower stratosphere (6 to 12 km) of constituents related to aircraft engine emissions and other pollutants. Aircraft operated by different airlines sample air at latitudes from the Arctic to Australia. This unique system includes specialized instrumentation, a special air inlet probe for sampling outside air, a computerized automatic control, and a data acquisition system. Air constituent and related flight data are tape recorded in flight for later computer processing on the ground.

  12. Automatically-computed prehospital severity scores are equivalent to scores based on medic documentation.

    PubMed

    Reisner, Andrew T; Chen, Liangyou; McKenna, Thomas M; Reifman, Jaques

    2008-10-01

    Prehospital severity scores can be used in routine prehospital care, mass casualty care, and military triage. If computers could reliably calculate clinical scores, new clinical and research methodologies would be possible. One obstacle is that vital signs measured automatically can be unreliable. We hypothesized that Signal Quality Indices (SQI's), computer algorithms that differentiate between reliable and unreliable monitored physiologic data, could improve the predictive power of computer-calculated scores. In a retrospective analysis of trauma casualties transported by air ambulance, we computed the Triage Revised Trauma Score (RTS) from archived travel monitor data. We compared the areas-under-the-curve (AUC's) of receiver operating characteristic curves for prediction of mortality and red blood cell transfusion for 187 subjects with comparable quantities of good-quality and poor-quality data. Vital signs deemed reliable by SQI's led to significantly more discriminatory severity scores than vital signs deemed unreliable. We also compared automatically-computed RTS (using the SQI's) versus RTS computed from vital signs documented by medics. For the subjects in whom the SQI algorithms identified 15 consecutive seconds of reliable vital signs data (n = 350), the automatically-computed scores' AUC's were the same as the medic-based scores' AUC's. Using the Prehospital Index in place of RTS led to very similar results, corroborating our findings. SQI algorithms improve automatically-computed severity scores, and automatically-computed scores using SQI's are equivalent to medic-based scores.

  13. Automation of a spectrophotometric method for measuring L -carnitine in human blood serum.

    PubMed

    Galan, A; Padros, A; Arambarri, M; Martin, S

    1998-01-01

    A spectrometric method for the determination of L-carnitine has been developed based on the reaction of the 5,5' dithiobis-(2-nitrobenzoic) acid (DTNB) and adapted to a Technicon RA-2000 automatic analyser Química Farmacéutica Bayer, S.A.). The detection limit of the method is 13.2 mumol/l, with a measurement interval ranging from 30 to 320 mumoll1. Imprecision and accuracy are good even at levels close to the detection limit (coeffcient of variation of 5.4% for within-run imprecision for a concentration of 35 mumol/l). A good correlation was observed between the method studied and the radiometric method. The method evaluated has suffcient analytical sensitivity to diagnose carnitine deficiencies. The short time period required for sample processing (30 samples in 40min), the simple methodology and apparatus, the ease of personnel training and the low cost of the reagents make this method a good alternative to the classical radiometric method for evaluating serum L-carnitine in clinical laboratories without radioactive installations.

  14. Automation of a spectrophotometric method for measuring L -carnitine in human blood serum

    PubMed Central

    Galan, Amparo; Padros, Anna; Arambarri, Marta; Martin, Silvia

    1998-01-01

    A spectrometric method for the determination of L-carnitine has been developed based on the reaction of the 5, 5 ′ dithiobis-(2-nitrobenzoic) acid (DTNB) and adapted to a Technicon RA-2000 automatic analyser Química Farmacéutica Bayer, S.A.). The detection limit of the method is 13.2 μmol/l, with a measurement interval ranging from 30 to 320 μmoll1. Imprecision and accuracy are good even at levels close to the detection limit (coeffcient of variation of 5.4% for within-run imprecision for a concentration of 35 μmol/l). A good correlation was observed between the method studied and the radiometric method. The method evaluated has suffcient analytical sensitivity to diagnose carnitine deficiencies. The short time period required for sample processing (30 samples in 40min), the simple methodology and apparatus, the ease of personnel training and the low cost of the reagents make this method a good alternative to the classical radiometric method for evaluating serum L-carnitine in clinical laboratories without radioactive installations. PMID:18924818

  15. Fully automatic characterization and data collection from crystals of biological macromolecules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Svensson, Olof; Malbet-Monaco, Stéphanie; Popov, Alexander

    A fully automatic system has been developed that performs X-ray centring and characterization of, and data collection from, large numbers of cryocooled crystals without human intervention. Considerable effort is dedicated to evaluating macromolecular crystals at synchrotron sources, even for well established and robust systems. Much of this work is repetitive, and the time spent could be better invested in the interpretation of the results. In order to decrease the need for manual intervention in the most repetitive steps of structural biology projects, initial screening and data collection, a fully automatic system has been developed to mount, locate, centre to themore » optimal diffraction volume, characterize and, if possible, collect data from multiple cryocooled crystals. Using the capabilities of pixel-array detectors, the system is as fast as a human operator, taking an average of 6 min per sample depending on the sample size and the level of characterization required. Using a fast X-ray-based routine, samples are located and centred systematically at the position of highest diffraction signal and important parameters for sample characterization, such as flux, beam size and crystal volume, are automatically taken into account, ensuring the calculation of optimal data-collection strategies. The system is now in operation at the new ESRF beamline MASSIF-1 and has been used by both industrial and academic users for many different sample types, including crystals of less than 20 µm in the smallest dimension. To date, over 8000 samples have been evaluated on MASSIF-1 without any human intervention.« less

  16. Utility of capillary microsampling for rat pharmacokinetic studies: Comparison of tail-vein bleed to jugular vein cannula sampling.

    PubMed

    Korfmacher, Walter; Luo, Yongyi; Ho, Stacy; Sun, Wei; Shen, Liduo; Wang, Jie; Wu, Zhongtao; Guo, Yang; Snow, Gregory; O'Shea, Thomas

    2015-01-01

    Serial sampling methods have been used for rat pharmacokinetic (PK) studies for over 20 years. Currently, it is still common to take 200-250 μL of blood at each timepoint when performing a PK study in rats and using serial sampling. While several techniques have been employed for collecting blood samples from rats, there is only limited published data to compare these methods. Recently, microsampling (≤ 50 μL) techniques have been reported as an alternative process for collecting blood samples from rats. In this report, five compounds were dosed orally into rats. For three proprietary compounds, jugular vein cannula (JVC) sampling was used to collect whole blood and plasma samples and capillary microsampling (CMS) was used to collect blood samples from the tail vein of the same animal. For the two other compounds, marketed drugs fluoxetine and glipizide, JVC sampling was used to collect both whole blood and blood CMS samples while tail-vein sampling from the same rats was also used to collect both whole blood and blood CMS samples. For the three proprietary compounds, the blood AUC as well as the blood concentration-time profile that were obtained from the tail vein were different from those obtained via JVC sampling. For fluoxetine, the blood total exposure (AUC) was not statistically different when comparing tail-vein sampling to JVC sampling, however the blood concentration-time profile that was obtained from the tail vein was different than the one obtained from JVC sampling. For glipizide, the blood AUC and concentration-time profile were not statistically different when comparing the tail-vein sampling to the JVC sampling. For both fluoxetine and glipizide, the blood concentration profiles obtained from CMS were equivalent to the blood concentration profiles obtained from the standard whole blood sampling, collected at the same sampling site. The data in this report provide strong evidence that blood CMS is a valuable small volume blood sampling approach for rats and that it provides results for test compound concentrations that are equivalent to those obtained from traditional whole blood sampling. The data also suggest that for some compounds, the concentration-time profile that is obtained for a test compound based on sampling from a rat tail vein may be different from that obtained from rat JVC sampling. In some cases, this shift in the concentration-time profile will result in different PK parameters for the test compound. Based on these observations, it is recommended that a consistent blood sampling method should be used for serial microsampling in discovery rat PK studies when testing multiple new chemical entities. If the rat tail vein sampling method is selected for PK screening, then conducting a bridging study on the lead compound is recommended to confirm that the rat PK obtained from JVC sampling is comparable to the tail-vein sampling. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Sampling theory and automated simulations for vertical sections, applied to human brain.

    PubMed

    Cruz-Orive, L M; Gelšvartas, J; Roberts, N

    2014-02-01

    In recent years, there have been substantial developments in both magnetic resonance imaging techniques and automatic image analysis software. The purpose of this paper is to develop stereological image sampling theory (i.e. unbiased sampling rules) that can be used by image analysts for estimating geometric quantities such as surface area and volume, and to illustrate its implementation. The methods will ideally be applied automatically on segmented, properly sampled 2D images - although convenient manual application is always an option - and they are of wide applicability in many disciplines. In particular, the vertical sections design to estimate surface area is described in detail and applied to estimate the area of the pial surface and of the boundary between cortex and underlying white matter (i.e. subcortical surface area). For completeness, cortical volume and mean cortical thickness are also estimated. The aforementioned surfaces were triangulated in 3D with the aid of FreeSurfer software, which provided accurate surface area measures that served as gold standards. Furthermore, a software was developed to produce digitized trace curves of the triangulated target surfaces automatically from virtual sections. From such traces, a new method (called the 'lambda method') is presented to estimate surface area automatically. In addition, with the new software, intersections could be counted automatically between the relevant surface traces and a cycloid test grid for the classical design. This capability, together with the aforementioned gold standard, enabled us to thoroughly check the performance and the variability of the different estimators by Monte Carlo simulations for studying the human brain. In particular, new methods are offered to split the total error variance into the orientations, sectioning and cycloid components. The latter prediction was hitherto unavailable--one is proposed here and checked by way of simulations on a given set of digitized vertical sections with automatically superimposed cycloid grids of three different sizes. Concrete and detailed recommendations are given to implement the methods. © 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.

  18. Development of an automatic volcanic ash sampling apparatus for active volcanoes

    NASA Astrophysics Data System (ADS)

    Shimano, Taketo; Nishimura, Takeshi; Chiga, Nobuyuki; Shibasaki, Yoshinobu; Iguchi, Masato; Miki, Daisuke; Yokoo, Akihiko

    2013-12-01

    We develop an automatic system for the sampling of ash fall particles, to be used for continuous monitoring of magma ascent and eruptive dynamics at active volcanoes. The system consists of a sampling apparatus and cameras to monitor surface phenomena during eruptions. The Sampling Apparatus for Time Series Unmanned Monitoring of Ash (SATSUMA-I and SATSUMA-II) is less than 10 kg in weight and works automatically for more than a month with a 10-kg lead battery to obtain a total of 30 to 36 samples in one cycle of operation. The time range covered in one cycle varies from less than an hour to several months, depending on the aims of observation, allowing researchers to target minute-scale fluctuations in a single eruptive event, as well as daily to weekly trends in persistent volcanic activity. The latest version, SATSUMA-II, also enables control of sampling parameters remotely by e-mail commands. Durability of the apparatus is high: our prototypes worked for several months, in rainy and typhoon seasons, at windy and humid locations, and under strong sunlight. We have been successful in collecting ash samples emitted from Showa crater almost everyday for more than 4 years (2008-2012) at Sakurajima volcano in southwest Japan.

  19. Method and apparatus for telemetry adaptive bandwidth compression

    NASA Technical Reports Server (NTRS)

    Graham, Olin L.

    1987-01-01

    Methods and apparatus are provided for automatic and/or manual adaptive bandwidth compression of telemetry. An adaptive sampler samples a video signal from a scanning sensor and generates a sequence of sampled fields. Each field and range rate information from the sensor are hence sequentially transmitted to and stored in a multiple and adaptive field storage means. The field storage means then, in response to an automatic or manual control signal, transfers the stored sampled field signals to a video monitor in a form for sequential or simultaneous display of a desired number of stored signal fields. The sampling ratio of the adaptive sample, the relative proportion of available communication bandwidth allocated respectively to transmitted data and video information, and the number of fields simultaneously displayed are manually or automatically selectively adjustable in functional relationship to each other and detected range rate. In one embodiment, when relatively little or no scene motion is detected, the control signal maximizes sampling ratio and causes simultaneous display of all stored fields, thus maximizing resolution and bandwidth available for data transmission. When increased scene motion is detected, the control signal is adjusted accordingly to cause display of fewer fields. If greater resolution is desired, the control signal is adjusted to increase the sampling ratio.

  20. Automated imaging of cellular spheroids with selective plane illumination microscopy on a chip (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Paiè, Petra; Bassi, Andrea; Bragheri, Francesca; Osellame, Roberto

    2017-02-01

    Selective plane illumination microscopy (SPIM) is an optical sectioning technique that allows imaging of biological samples at high spatio-temporal resolution. Standard SPIM devices require dedicated set-ups, complex sample preparation and accurate system alignment, thus limiting the automation of the technique, its accessibility and throughput. We present a millimeter-scaled optofluidic device that incorporates selective plane illumination and fully automatic sample delivery and scanning. To this end an integrated cylindrical lens and a three-dimensional fluidic network were fabricated by femtosecond laser micromachining into a single glass chip. This device can upgrade any standard fluorescence microscope to a SPIM system. We used SPIM on a CHIP to automatically scan biological samples under a conventional microscope, without the need of any motorized stage: tissue spheroids expressing fluorescent proteins were flowed in the microchannel at constant speed and their sections were acquired while passing through the light sheet. We demonstrate high-throughput imaging of the entire sample volume (with a rate of 30 samples/min), segmentation and quantification in thick (100-300 μm diameter) cellular spheroids. This optofluidic device gives access to SPIM analyses to non-expert end-users, opening the way to automatic and fast screening of a high number of samples at subcellular resolution.

  1. Machine for Automatic Bacteriological Pour Plate Preparation

    PubMed Central

    Sharpe, A. N.; Biggs, D. R.; Oliver, R. J.

    1972-01-01

    A fully automatic system for preparing poured plates for bacteriological analyses has been constructed and tested. The machine can make decimal dilutions of bacterial suspensions, dispense measured amounts into petri dishes, add molten agar, mix the dish contents, and label the dishes with sample and dilution numbers at the rate of 2,000 dishes per 8-hr day. In addition, the machine can be programmed to select different media so that plates for different types of bacteriological analysis may be made automatically from the same sample. The machine uses only the components of the media and sterile polystyrene petri dishes; requirements for all other materials, such as sterile pipettes and capped bottles of diluents and agar, are eliminated. Images PMID:4560475

  2. A system for the automatic measurement and digital display of systolic and diastolic blood pressures

    NASA Technical Reports Server (NTRS)

    Schulze, A. E.

    1971-01-01

    Basic components of system are - occluding cuff with mounted cuff microscope, cuff pump deflator, pressure transducer, preamplifier unit, electrocardiograph machine, an analog to digital convertor unit, and digital display unit. System utilizes indirect auscultatory method, based on Korotkoff sounds, for measurement.

  3. An efficient passive planar micromixer with ellipse-like micropillars for continuous mixing of human blood.

    PubMed

    Tran-Minh, Nhut; Dong, Tao; Karlsen, Frank

    2014-10-01

    In this paper, a passive planar micromixer with ellipse-like micropillars is proposed to operate in the laminar flow regime for high mixing efficiency. With a splitting and recombination (SAR) concept, the diffusion distance of the fluids in a micromixer with ellipse-like micropillars was decreased. Thus, space usage for micromixer of an automatic sample collection system is also minimized. Numerical simulation was conducted to evaluate the performance of proposed micromixer by solving the governing Navier-Stokes equation and convection-diffusion equation. With software (COMSOL 4.3) for computational fluid dynamics (CFD) we simulated the mixing of fluids in a micromixer with ellipse-like micropillars and basic T-type mixer in a laminar flow regime. The efficiency of the proposed micromixer is shown in numerical results and is verified by measurement results. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. Online Deviation Detection for Medical Processes

    PubMed Central

    Christov, Stefan C.; Avrunin, George S.; Clarke, Lori A.

    2014-01-01

    Human errors are a major concern in many medical processes. To help address this problem, we are investigating an approach for automatically detecting when performers of a medical process deviate from the acceptable ways of performing that process as specified by a detailed process model. Such deviations could represent errors and, thus, detecting and reporting deviations as they occur could help catch errors before harm is done. In this paper, we identify important issues related to the feasibility of the proposed approach and empirically evaluate the approach for two medical procedures, chemotherapy and blood transfusion. For the evaluation, we use the process models to generate sample process executions that we then seed with synthetic errors. The process models describe the coordination of activities of different process performers in normal, as well as in exceptional situations. The evaluation results suggest that the proposed approach could be applied in clinical settings to help catch errors before harm is done. PMID:25954343

  5. Realizing parameterless automatic classification of remote sensing imagery using ontology engineering and cyberinfrastructure techniques

    NASA Astrophysics Data System (ADS)

    Sun, Ziheng; Fang, Hui; Di, Liping; Yue, Peng

    2016-09-01

    It was an untouchable dream for remote sensing experts to realize total automatic image classification without inputting any parameter values. Experts usually spend hours and hours on tuning the input parameters of classification algorithms in order to obtain the best results. With the rapid development of knowledge engineering and cyberinfrastructure, a lot of data processing and knowledge reasoning capabilities become online accessible, shareable and interoperable. Based on these recent improvements, this paper presents an idea of parameterless automatic classification which only requires an image and automatically outputs a labeled vector. No parameters and operations are needed from endpoint consumers. An approach is proposed to realize the idea. It adopts an ontology database to store the experiences of tuning values for classifiers. A sample database is used to record training samples of image segments. Geoprocessing Web services are used as functionality blocks to finish basic classification steps. Workflow technology is involved to turn the overall image classification into a total automatic process. A Web-based prototypical system named PACS (Parameterless Automatic Classification System) is implemented. A number of images are fed into the system for evaluation purposes. The results show that the approach could automatically classify remote sensing images and have a fairly good average accuracy. It is indicated that the classified results will be more accurate if the two databases have higher quality. Once the experiences and samples in the databases are accumulated as many as an expert has, the approach should be able to get the results with similar quality to that a human expert can get. Since the approach is total automatic and parameterless, it can not only relieve remote sensing workers from the heavy and time-consuming parameter tuning work, but also significantly shorten the waiting time for consumers and facilitate them to engage in image classification activities. Currently, the approach is used only on high resolution optical three-band remote sensing imagery. The feasibility using the approach on other kinds of remote sensing images or involving additional bands in classification will be studied in future.

  6. Isolation of Microarray-Grade Total RNA, MicroRNA, and DNA from a Single PAXgene Blood RNA Tube

    PubMed Central

    Kruhøffer, Mogens; Dyrskjøt, Lars; Voss, Thorsten; Lindberg, Raija L.P.; Wyrich, Ralf; Thykjaer, Thomas; Orntoft, Torben F.

    2007-01-01

    We have developed a procedure for isolation of microRNA and genomic DNA in addition to total RNA from whole blood stabilized in PAXgene Blood RNA tubes. The procedure is based on automatic extraction on a BioRobot MDx and includes isolation of DNA from a fraction of the stabilized blood and recovery of small RNA species that are otherwise lost. The procedure presented here is suitable for large-scale experiments and is amenable to further automation. Procured total RNA and DNA was tested using Affymetrix Expression and single-nucleotide polymorphism GeneChips, respectively, and isolated microRNA was tested using spotted locked nucleic acid-based microarrays. We conclude that the yield and quality of total RNA, microRNA, and DNA from a single PAXgene blood RNA tube is sufficient for downstream microarray analysis. PMID:17690207

  7. Noncontact discrimination of animal and human blood with vacuum blood vessel and factors affect the discrimination

    NASA Astrophysics Data System (ADS)

    Zhang, Linna; Zhang, Shengzhao; Sun, Meixiu; Li, Hongxiao; Li, Yingxin; Fu, Zhigang; Guan, Yang; Li, Gang; Lin, Ling

    2017-03-01

    Discrimination of human and nonhuman blood is crucial for import-export ports and inspection and quarantine departments. Current methods are usually destructive, complicated and time-consuming. We had previously demonstrated that visible diffuse reflectance spectroscopy combining PLS-DA method can successfully realize human blood discrimination. In that research, the spectra were measured with the fiber probe under the surface of blood samples. However, open sampling may pollute the blood samples. Virulence factors in blood samples can also endanger inspectors. In this paper, we explored the classification effect with the blood samples measured in the original containers-vacuum blood vessel. Furthermore, we studied the impact of different conditions of blood samples, such as coagulation and hemolysis, on the prediction ability of the discrimination model. The calibration model built with blood samples in different conditions displayed a satisfactory prediction result. This research demonstrated that visible and near-infrared diffuse reflectance spectroscopy method was potential for noncontact discrimination of human blood.

  8. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  9. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  10. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  11. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  12. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  13. Blood rheology of angina pectoris patients with myocardial injury after ischemia reperfusion and its effect on thromboxane B2 levels.

    PubMed

    Wang, Wenlong; Huang, Xiaohui; Sun, Yiyong; Zhang, Jinying

    2018-01-01

    This study investigated the changes in the blood rheology of patients with angina pectoris and ischemia reperfusion injury and their effect on thromboxane B 2 (TXB 2 ) levels to examine their relationship. Forty patients with unstable angina pectoris who underwent elective percutaneous coronary intervention (PCI) were selected for the unstable angina group (UA group) and forty patients deemed free of coronary heart disease by coronary angiography were selected for the control group. Venous blood samples were drawn from all participants; patients in the UA group had blood drawn 1 day before and 1 day after the PCI procedure. Blood samples were used to analyze blood rheology and examine hemodynamic parameters, at the same time radioimmunoassay was applied to measure the concentrations of serum endothelin-1 (ET-1) and TXB 2 , and an automatic biochemical analyzer was used to detect the content of superoxide dismutase (SOD) and malondialdehyde (MDA). Our results showed the patients in the UA group all presented hyperviscosity; however the levels were higher for the patients in the UA group (after surgery) than for those in the UA group (before surgery). Patients in the control group exhibited normal levels, and the differences among groups were significant in pairwise comparisons (P<0.05). The levels of ET-1 and TXB 2 in the UA group were increased compared with those in control group and they were highest after surgery (P<0.05). For the patients in the UA group, the serum TXB 2 concentration increased gradually along with the increase in risk stratification. There were significant differences in comparisons between different strata and between UA patients and those in the control group (P<0.05). The serum SOD activity levels were lowest in the UA group (after surgery), higher in the UA group (before surgery) and highest in the control group. Conversely, the MDA content was highest in the UA group (after surgery), lower in the UA group (before surgery) and smallest in the control group; there were significant differences in pairwise comparisons. Based on our findings, a hyperviscosity syndrome was manifested in the blood rheology of patients with angina pectoris and ischemia reperfusion injury. The higher than normal TXB 2 levels can be used as a marker of platelet activation and a reference for clinical risk stratification, thus having great significance for the prevention and treatment of ischemia reperfusion injury and assessment of disease progression.

  14. Dried blood spot measurement: application in tacrolimus monitoring using limited sampling strategy and abbreviated AUC estimation.

    PubMed

    Cheung, Chi Yuen; van der Heijden, Jaques; Hoogtanders, Karin; Christiaans, Maarten; Liu, Yan Lun; Chan, Yiu Han; Choi, Koon Shing; van de Plas, Afke; Shek, Chi Chung; Chau, Ka Foon; Li, Chun Sang; van Hooff, Johannes; Stolk, Leo

    2008-02-01

    Dried blood spot (DBS) sampling and high-performance liquid chromatography tandem-mass spectrometry have been developed in monitoring tacrolimus levels. Our center favors the use of limited sampling strategy and abbreviated formula to estimate the area under concentration-time curve (AUC(0-12)). However, it is inconvenient for patients because they have to wait in the center for blood sampling. We investigated the application of DBS method in tacrolimus level monitoring using limited sampling strategy and abbreviated AUC estimation approach. Duplicate venous samples were obtained at each time point (C(0), C(2), and C(4)). To determine the stability of blood samples, one venous sample was sent to our laboratory immediately. The other duplicate venous samples, together with simultaneous fingerprick blood samples, were sent to the University of Maastricht in the Netherlands. Thirty six patients were recruited and 108 sets of blood samples were collected. There was a highly significant relationship between AUC(0-12), estimated from venous blood samples, and fingerprick blood samples (r(2) = 0.96, P < 0.0001). Moreover, there was an excellent correlation between whole blood venous tacrolimus levels in the two centers (r(2) = 0.97; P < 0.0001). The blood samples were stable after long-distance transport. DBS sampling can be used in centers using limited sampling and abbreviated AUC(0-12) strategy as drug monitoring.

  15. A device for automatic photoelectric control of the analytical gap for emission spectrographs

    USGS Publications Warehouse

    Dietrich, John A.; Cooley, Elmo F.; Curry, Kenneth J.

    1977-01-01

    A photoelectric device has been built that automatically controls the analytical gap between electrodes during excitation period. The control device allows for precise control of the analytical gap during the arcing process of samples, resulting in better precision of analysis.

  16. Towards Clinical Applications of Blood-Borne miRNA Signatures: The Influence of the Anticoagulant EDTA on miRNA Abundance.

    PubMed

    Leidinger, Petra; Backes, Christina; Rheinheimer, Stefanie; Keller, Andreas; Meese, Eckart

    2015-01-01

    Circulating microRNAs (miRNAs) from blood are increasingly recognized as biomarker candidates for human diseases. Clinical routine settings frequently include blood sampling in tubes with EDTA as anticoagulant without considering the influence of phlebotomy on the overall miRNA expression pattern. We collected blood samples from six healthy individuals each in an EDTA blood collection tube. Subsequently, the blood was transferred into PAXgeneTM tubes at three different time points, i.e. directly (0 min), 10 min, and 2 h after phlebotomy. As control blood was also directly collected in PAXgeneTM blood RNA tubes that contain a reagent to directly lyse blood cells and stabilize their content. For all six blood donors at the four conditions (24 samples) we analyzed the abundance of 1,205 miRNAs by human Agilent miRNA V16 microarrays. While we found generally a homogenous pattern of the miRNA abundance in all 24 samples, the duration of the EDTA treatment appears to influence the miRNA abundance of specific miRNAs. The most significant changes are observed after longer EDTA exposition. Overall, the impact of the different blood sample conditions on the miRNA pattern was substantially lower than intra-individual variations. While samples belonging to one of the six individuals mostly cluster together, there was no comparable clustering for any of the four tested blood sampling conditions. The most affected miRNA was miR-769-3p that was not detected in any of the six PAXgene blood samples, but in all EDTA 2h samples. Accordingly, hsa-miR-769-3p was also the only miRNA that showed a significantly different abundance between the 4 blood sample conditions by an ANOVA analysis (Benjamini-Hochberg adjusted p-value of 0.003). Validation by qRT-PCR confirmed this finding. The pattern of blood-borne miRNA abundance is rather homogenous between the four tested blood sample conditions of six blood donors. There was a clustering between the miRNA profiles that belong to a specific blood donor, but not between any of the four tested blood sampling conditions. The results show a limited overall impact of the blood sampling conditions on the miRNA pattern. Notwithstanding, the abundance of single miRNAs can be significantly altered by different blood sampling conditions.

  17. Personal Computer System for Automatic Coronary Venous Flow Measurement

    PubMed Central

    Dew, Robert B.

    1985-01-01

    We developed an automated system based on an IBM PC/XT Personal computer to measure coronary venous blood flow during cardiac catheterization. Flow is determined by a thermodilution technique in which a cold saline solution is infused through a catheter into the coronary venous system. Regional temperature fluctuations sensed by the catheter are used to determine great cardiac vein and coronary sinus blood flow. The computer system replaces manual methods of acquiring and analyzing temperature data related to flow measurement, thereby increasing the speed and accuracy with which repetitive flow determinations can be made.

  18. Analysis of 2D Phase Contrast MRI in Renal Arteries by Self Organizing Maps

    NASA Astrophysics Data System (ADS)

    Zöllner, Frank G.; Schad, Lothar R.

    We present an approach based on self organizing maps to segment renal arteries from 2D PC Cine MR, images to measure blood velocity and flow. Such information are important in grading renal artery stenosis and support the decision on surgical interventions like percu-tan transluminal angioplasty. Results show that the renal arteries could be extracted automatically. The corresponding velocity profiles show high correlation (r=0.99) compared those from manual delineated vessels. Furthermore, the method could detect possible blood flow patterns within the vessel.

  19. [Mutations of resistance of HIV-1 in previously untreated patients at penitentiary centers of the Autonomous Community of Valencia, Spain. REPRICOVA study].

    PubMed

    García-Guerrero, Julio; Herrero, Agustín; Vera, Enrique; Almenara, José M; Araújo, Rosa; Saurí, Vicente V; Castellano, Juan C; Fernández-Clemente, Luis; Bedia, Miguel; Llorente, María I; González-Morán, Francisco

    2002-03-02

    Our purpose was to determine the prevalence of mutations of resistance to nucleoside inhibitors of reverse transcriptase (NIRT) and protease inhibitors (PI) in the HIV-1 genotype of naïve infected subjects in the prisons of the Autonomous Community of Valencia, Spain. Multicentric, descriptive, cross-sectional study of prevalence including a systematic stratified and randomised sampling by centres. Demographic, clinical, virological and immunological data were collected. The HIV gene of protease and transcriptase was studied in peripheral blood plasma samples by means of double PCR amplification and subsequent automatic sequence. Reference: wild strain HXB2. Plasma was obtained from 133 individuals (119 men and 14 women). 117 samples were selected and the rest did not have enough copies for transcription. With regard to NIRT, 7 samples (5.2% of total) showed some mutation of resistance: M41L, D67N, L210W and K219Q, all them secondary to and associated with resistance to zidovudine, abacavir as well as group B multinucleoside-resistance. With regard to PI, only one sample showed a primary mutation, M46I, which was associated with resistance to indinavir. Moreover, a further 41 samples were found to express some secondary mutation. In our series, there was a low number of primary mutations of resistance. These results allow us to exclude the systematic use of resistance tests before an initiation antiretroviral therapy.

  20. Automatic sample changer control software for automation of neutron activation analysis process in Malaysian Nuclear Agency

    NASA Astrophysics Data System (ADS)

    Yussup, N.; Ibrahim, M. M.; Rahman, N. A. A.; Mokhtar, M.; Salim, N. A. A.; Soh@Shaari, S. C.; Azman, A.; Lombigit, L.; Azman, A.; Omar, S. A.

    2018-01-01

    Most of the procedures in neutron activation analysis (NAA) process that has been established in Malaysian Nuclear Agency (Nuclear Malaysia) since 1980s were performed manually. These manual procedures carried out by the NAA laboratory personnel are time consuming and inefficient especially for sample counting and measurement process. The sample needs to be changed and the measurement software needs to be setup for every one hour counting time. Both of these procedures are performed manually for every sample. Hence, an automatic sample changer system (ASC) that consists of hardware and software is developed to automate sample counting process for up to 30 samples consecutively. This paper describes the ASC control software for NAA process which is designed and developed to control the ASC hardware and call GammaVision software for sample measurement. The software is developed by using National Instrument LabVIEW development package.

  1. Recent Research on the Automated Mass Measuring System

    NASA Astrophysics Data System (ADS)

    Yao, Hong; Ren, Xiao-Ping; Wang, Jian; Zhong, Rui-Lin; Ding, Jing-An

    The research development of robotic measurement system as well as the representative automatic system were introduced in the paper, and then discussed a sub-multiple calibration scheme adopted on a fully-automatic CCR10 system effectively. Automatic robot system can be able to perform the dissemination of the mass scale without any manual intervention as well as the fast speed calibration of weight samples against a reference weight. At the last, evaluation of the expanded uncertainty was given out.

  2. Evaluation of needle trap micro-extraction and automatic alveolar sampling for point-of-care breath analysis.

    PubMed

    Trefz, Phillip; Rösner, Lisa; Hein, Dietmar; Schubert, Jochen K; Miekisch, Wolfram

    2013-04-01

    Needle trap devices (NTDs) have shown many advantages such as improved detection limits, reduced sampling time and volume, improved stability, and reproducibility if compared with other techniques used in breath analysis such as solid-phase extraction and solid-phase micro-extraction. Effects of sampling flow (2-30 ml/min) and volume (10-100 ml) were investigated in dry gas standards containing hydrocarbons, aldehydes, and aromatic compounds and in humid breath samples. NTDs contained (single-bed) polymer packing and (triple-bed) combinations of divinylbenzene/Carbopack X/Carboxen 1000. Substances were desorbed from the NTDs by means of thermal expansion and analyzed by gas chromatography-mass spectrometry. An automated CO2-controlled sampling device for direct alveolar sampling at the point-of-care was developed and tested in pilot experiments. Adsorption efficiency for small volatile organic compounds decreased and breakthrough increased when sampling was done with polymer needles from a water-saturated matrix (breath) instead from dry gas. Humidity did not affect analysis with triple-bed NTDs. These NTDs showed only small dependencies on sampling flow and low breakthrough from 1-5 %. The new sampling device was able to control crucial parameters such as sampling flow and volume. With triple-bed NTDs, substance amounts increased linearly with increasing sample volume when alveolar breath was pre-concentrated automatically. When compared with manual sampling, automatic sampling showed comparable or better results. Thorough control of sampling and adequate choice of adsorption material is mandatory for application of needle trap micro-extraction in vivo. The new CO2-controlled sampling device allows direct alveolar sampling at the point-of-care without the need of any additional sampling, storage, or pre-concentration steps.

  3. A comparison of the comfort and convenience of automatic safety belt systems among selected 1988-1989 model year automobiles

    DOT National Transportation Integrated Search

    1989-06-01

    Author's abstract: A nonrandom sample of 120 disproportionately short, tall, and overweight drivers compared the comfort and convenience of the automatic safety belt systems used in seventeen automobiles. Nine vehicles had motorized shoulder belts wi...

  4. 40 CFR Appendix E to Part 403 - Sampling Procedures

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... done manually or automatically, and discretely or continuously. If discrete sampling is employed, at least 12 aliquots should be composited. Discrete sampling may be flow proportioned either by varying the...

  5. Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.

    PubMed

    Mullins, Garrett R; Bruns, David E

    2017-10-01

    Transport of blood samples through pneumatic tube systems (PTSs) generates air bubbles in transported blood samples and, with increasing duration of transport, the appearance of hemolysis. We investigated the role of air-bubble formation in PTS-induced hemolysis. Air was introduced into blood samples for 0, 1, 3 or 5min to form air bubbles. Hemolysis in the blood was assessed by (H)-index, lactate dehydrogenase (LD) and potassium in plasma. In an effort to prevent PTS-induced hemolysis, blood sample tubes were completely filled, to prevent air bubble formation, and compared with partially filled samples after PTS transport. We also compared hemolysis in anticoagulated vs clotted blood subjected to PTS transport. As with transport through PTSs, the duration of air bubble formation in blood by a gentle stream of air predicted the extent of hemolysis as measured by H-index (p<0.01), LD (p<0.01), and potassium (p<0.02) in plasma. Removing air space in a blood sample prevented bubble formation and fully protected the blood from PTS-induced hemolysis (p<0.02 vs conventionally filled collection tube). Clotted blood developed less foaming during PTS transport and was partially protected from hemolysis vs anticoagulated blood as indicated by lower LD (p<0.03) in serum than in plasma after PTS sample transport. Prevention of air bubble formation in blood samples during PTS transport protects samples from hemolysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Towards Clinical Applications of Blood-Borne miRNA Signatures: The Influence of the Anticoagulant EDTA on miRNA Abundance

    PubMed Central

    Leidinger, Petra; Backes, Christina; Rheinheimer, Stefanie; Keller, Andreas; Meese, Eckart

    2015-01-01

    Background Circulating microRNAs (miRNAs) from blood are increasingly recognized as biomarker candidates for human diseases. Clinical routine settings frequently include blood sampling in tubes with EDTA as anticoagulant without considering the influence of phlebotomy on the overall miRNA expression pattern. We collected blood samples from six healthy individuals each in an EDTA blood collection tube. Subsequently, the blood was transferred into PAXgeneTM tubes at three different time points, i.e. directly (0 min), 10 min, and 2 h after phlebotomy. As control blood was also directly collected in PAXgeneTM blood RNA tubes that contain a reagent to directly lyse blood cells and stabilize their content. For all six blood donors at the four conditions (24 samples) we analyzed the abundance of 1,205 miRNAs by human Agilent miRNA V16 microarrays. Results While we found generally a homogenous pattern of the miRNA abundance in all 24 samples, the duration of the EDTA treatment appears to influence the miRNA abundance of specific miRNAs. The most significant changes are observed after longer EDTA exposition. Overall, the impact of the different blood sample conditions on the miRNA pattern was substantially lower than intra-individual variations. While samples belonging to one of the six individuals mostly cluster together, there was no comparable clustering for any of the four tested blood sampling conditions. The most affected miRNA was miR-769-3p that was not detected in any of the six PAXgene blood samples, but in all EDTA 2h samples. Accordingly, hsa-miR-769-3p was also the only miRNA that showed a significantly different abundance between the 4 blood sample conditions by an ANOVA analysis (Benjamini-Hochberg adjusted p-value of 0.003). Validation by qRT-PCR confirmed this finding. Conclusion The pattern of blood-borne miRNA abundance is rather homogenous between the four tested blood sample conditions of six blood donors. There was a clustering between the miRNA profiles that belong to a specific blood donor, but not between any of the four tested blood sampling conditions. The results show a limited overall impact of the blood sampling conditions on the miRNA pattern. Notwithstanding, the abundance of single miRNAs can be significantly altered by different blood sampling conditions. PMID:26599228

  7. Effect of storage time, temperature, antioxidant and thawing on fatty acid composition of plasma, serum and red blood cells - A pilot biobank study.

    PubMed

    Araujo, Pedro; Bjørkkjær, Tormod; Frøyland, Livar; Waagbø, Rune

    2018-02-01

    It studies on the factors that affect the stability of fatty acid profiles from human blood specimens are generally performed by evaluating the effect of a single factor on an individual fatty acid and excluding a considerable amount of data from the total fatty acid profiles. The stability of fatty acids from plasma, serum and red blood cells (RBC) was evaluated in terms of time, temperature, antioxidant and thawing. The fatty acids were methylated and analyzed by gas chromatography. The large volume of data is evaluated simultaneously and automatically by observing an Excel-based colour scale that indicates whether the fatty acid profiles have changed significantly as a result of the storage time (0-52weeks), temperature (-20°C/-80°C), butylated hydroxytoluene (BHT) antioxidant (presence/absence) or thawing (single/multiple). Fatty acids from plasma were stable at both temperatures (-20°C/-80°C) regardless of BHT. Fatty acids from serum without BHT degrades faster at -80°C than -20°C and fatty acids from RBC without BHT degrades faster at -20°C than -80°C. Addition of BHT inhibits this effect in serum and RBC. Multiple thawing of RBC without BHT demonstrated that polyunsaturated fatty acids were generally more susceptible for changes at -80°C than at -20°C while BHT prevents partially this effect. This study draws attention to the importance of pre-analytical considerations when storing blood samples in biobanks and the need of careful judgments when analyzing fatty acids profiles. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  8. Fluid shifts, vasodilatation and ambulatory blood pressure reduction during long duration spaceflight

    PubMed Central

    Norsk, Peter; Asmar, Ali; Damgaard, Morten; Christensen, Niels Juel

    2015-01-01

    Acute weightlessness in space induces a fluid shift leading to central volume expansion. Simultaneously, blood pressure is either unchanged or decreased slightly. Whether these effects persist for months in space is unclear. Twenty-four hour ambulatory brachial arterial pressures were automatically recorded at 1–2 h intervals with portable equipment in eight male astronauts: once before launch, once between 85 and 192 days in space on the International Space Station and, finally, once at least 2 months after flight. During the same 24 h, cardiac output (rebreathing method) was measured two to five times (on the ground seated), and venous blood was sampled once (also seated on the ground) for determination of plasma catecholamine concentrations. The 24 h average systolic, diastolic and mean arterial pressures (mean ± se) in space were reduced by 8 ± 2 mmHg (P = 0.01; ANOVA), 9 ± 2 mmHg (P < 0.001) and 10 ± 3 mmHg (P = 0.006), respectively. The nightly blood pressure dip of 8 ± 3 mmHg (P = 0.015) was maintained. Cardiac stroke volume and output increased by 35 ± 10% and 41 ± 9% (P < 0.001); heart rate and catecholamine concentrations were unchanged; and systemic vascular resistance was reduced by 39 ± 4% (P < 0.001). The increase in cardiac stroke volume and output is more than previously observed during short duration flights and might be a precipitator for some of the vision problems encountered by the astronauts. The spaceflight vasodilatation mechanism needs to be explored further. PMID:25774397

  9. Are self-reported telemonitored blood pressure readings affected by end-digit preference: a prospective cohort study in Scotland.

    PubMed

    Parker, Richard A; Paterson, Mary; Padfield, Paul; Pinnock, Hilary; Hanley, Janet; Hammersley, Vicky S; Steventon, Adam; McKinstry, Brian

    2018-01-31

    Simple forms of blood pressure (BP) telemonitoring require patients to text readings to central servers creating an opportunity for both entry error and manipulation. We wished to determine if there was an apparent preference for particular end digits and entries which were just below target BPs which might suggest evidence of data manipulation. Prospective cohort study SETTING: 37 socioeconomically diverse primary care practices from South East Scotland. Patients were recruited with hypertension to a telemonitoring service in which patients submitted home BP readings by manually transcribing the measurements into text messages for transmission ('patient-texted system'). These readings were compared with those from primary care patients with uncontrolled hypertension using a system in which readings were automatically transmitted, eliminating the possibility of manipulation of values ('automatic-transmission system'). A generalised estimating equations method was used to compare BP readings between the patient-texted and automatic-transmission systems, while taking into account clustering of readings within patients. A total of 44 150 BP readings were analysed on 1068 patients using the patient-texted system compared with 20 705 readings on 199 patients using the automatic-transmission system. Compared with the automatic-transmission data, the patient-texted data showed a significantly higher proportion of occurrences of both systolic and diastolic BP having a zero end digit (OR 2.1, 95% CI 1.7 to 2.6) although incidence was <2% of readings. Similarly, there was a preference for systolic 134 and diastolic 84 (the threshold for alerts was 135/85) (134 systolic BP OR 1.5, 95% CI 1.3 to 1.8; 84 diastolic BP OR 1.5, 95% CI 1.3 to 1.9). End-digit preference for zero numbers and specific-value preference for readings just below the alert threshold exist among patients in self-reporting their BP using telemonitoring. However, the proportion of readings affected is small and unlikely to be clinically important. ISRCTN72614272; Post-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. Singular value decomposition of received ultrasound signal to separate tissue, blood flow, and cavitation signals

    NASA Astrophysics Data System (ADS)

    Ikeda, Hayato; Nagaoka, Ryo; Lafond, Maxime; Yoshizawa, Shin; Iwasaki, Ryosuke; Maeda, Moe; Umemura, Shin-ichiro; Saijo, Yoshifumi

    2018-07-01

    High-intensity focused ultrasound is a noninvasive treatment applied by externally irradiating ultrasound to the body to coagulate the target tissue thermally. Recently, it has been proposed as a noninvasive treatment for vascular occlusion to replace conventional invasive treatments. Cavitation bubbles generated by the focused ultrasound can accelerate the effect of thermal coagulation. However, the tissues surrounding the target may be damaged by cavitation bubbles generated outside the treatment area. Conventional methods based on Doppler analysis only in the time domain are not suitable for monitoring blood flow in the presence of cavitation. In this study, we proposed a novel filtering method based on the differences in spatiotemporal characteristics, to separate tissue, blood flow, and cavitation by employing singular value decomposition. Signals from cavitation and blood flow were extracted automatically using spatial and temporal covariance matrices.

  11. Automatic energy calibration algorithm for an RBS setup

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silva, Tiago F.; Moro, Marcos V.; Added, Nemitala

    2013-05-06

    This work describes a computer algorithm for automatic extraction of the energy calibration parameters from a Rutherford Back-Scattering Spectroscopy (RBS) spectrum. Parameters like the electronic gain, electronic offset and detection resolution (FWHM) of a RBS setup are usually determined using a standard sample. In our case, the standard sample comprises of a multi-elemental thin film made of a mixture of Ti-Al-Ta that is analyzed at the beginning of each run at defined beam energy. A computer program has been developed to extract automatically the calibration parameters from the spectrum of the standard sample. The code evaluates the first derivative ofmore » the energy spectrum, locates the trailing edges of the Al, Ti and Ta peaks and fits a first order polynomial for the energy-channel relation. The detection resolution is determined fitting the convolution of a pre-calculated theoretical spectrum. To test the code, data of two years have been analyzed and the results compared with the manual calculations done previously, obtaining good agreement.« less

  12. Components of Implicit Stigma against Mental Illness among Chinese Students

    PubMed Central

    Wang, Xiaogang; Huang, Xiting; Jackson, Todd; Chen, Ruijun

    2012-01-01

    Although some research has examined negative automatic aspects of attitudes toward mental illness via relatively indirect measures among Western samples, it is unclear whether negative attitudes can be automatically activated in individuals from non-Western countries. This study attempted to validate results from Western samples with Chinese college students. We first examined the three-component model of implicit stigma (negative cognition, negative affect, and discriminatory tendencies) toward mental illness with the Single Category Implicit Association Test (SC-IAT). We also explored the relationship between explicit and implicit stigma among 56 Chinese university college students. In the three separate SC-IATs and the combined SC-IAT, automatic associations between mental illness and negative descriptors were stronger relative to those with positive descriptors and the implicit effect of cognitive and affective SC-IATs were significant. Explicit and implicit measures of stigma toward mental illness were unrelated. In our sample, women's overall attitudes toward mental illness were more negative than men's were, but no gender differences were found for explicit measures. These findings suggested that implicit stigma toward mental illness exists in Chinese students, and provide some support for the three-component model of implicit stigma toward mental illness. Future studies that focus on automatic components of stigmatization and stigma-reduction in China are warranted. PMID:23029366

  13. DALMATIAN: An Algorithm for Automatic Cell Detection and Counting in 3D.

    PubMed

    Shuvaev, Sergey A; Lazutkin, Alexander A; Kedrov, Alexander V; Anokhin, Konstantin V; Enikolopov, Grigori N; Koulakov, Alexei A

    2017-01-01

    Current 3D imaging methods, including optical projection tomography, light-sheet microscopy, block-face imaging, and serial two photon tomography enable visualization of large samples of biological tissue. Large volumes of data obtained at high resolution require development of automatic image processing techniques, such as algorithms for automatic cell detection or, more generally, point-like object detection. Current approaches to automated cell detection suffer from difficulties originating from detection of particular cell types, cell populations of different brightness, non-uniformly stained, and overlapping cells. In this study, we present a set of algorithms for robust automatic cell detection in 3D. Our algorithms are suitable for, but not limited to, whole brain regions and individual brain sections. We used watershed procedure to split regional maxima representing overlapping cells. We developed a bootstrap Gaussian fit procedure to evaluate the statistical significance of detected cells. We compared cell detection quality of our algorithm and other software using 42 samples, representing 6 staining and imaging techniques. The results provided by our algorithm matched manual expert quantification with signal-to-noise dependent confidence, including samples with cells of different brightness, non-uniformly stained, and overlapping cells for whole brain regions and individual tissue sections. Our algorithm provided the best cell detection quality among tested free and commercial software.

  14. Reading Ability Is Negatively Related to Stroop Interference

    ERIC Educational Resources Information Center

    Protopapas, Athanassios; Archonti, Anastasia; Skaloumbakas, Christos

    2007-01-01

    Stroop interference is often taken as evidence for reading automaticity even though young and poor readers, who presumably lack reading automaticity, present strong interference. Here the relationship between reading skills and Stroop interference was studied in a 7th-grade sample. Greater interference was observed in children diagnosed with…

  15. NEAR-CONTINUOUS MEASUREMENT OF HYDROGEN SULFIDE AND CARBONYL SULFIDE BY AN AUTOMATIC GAS CHROMATOGRAPH

    EPA Science Inventory

    An automatic gas chromatograph with a flame photometric detector that samples and analyzes hydrogen sulfide and carbonyl sulfide at 30-s intervals is described. Temperature programming was used to elute trace amounts of carbon disulfide present in each injection from a Supelpak-S...

  16. SAVLOC, computer program for automatic control and analysis of X-ray fluorescence experiments

    NASA Technical Reports Server (NTRS)

    Leonard, R. F.

    1977-01-01

    A program for a PDP-15 computer is presented which provides for control and analysis of trace element determinations by using X-ray fluorescence. The program simultaneously handles data accumulation for one sample and analysis of data from previous samples. Data accumulation consists of sample changing, timing, and data storage. Analysis requires the locating of peaks in X-ray spectra, determination of intensities of peaks, identification of origins of peaks, and determination of a real density of the element responsible for each peak. The program may be run in either a manual (supervised) mode or an automatic (unsupervised) mode.

  17. Cardiac Structure and Function in Humans: A New Cardiovascular Physiology Laboratory

    ERIC Educational Resources Information Center

    Song, Su; Burleson, Paul D.; Passo, Stanley; Messina, Edward J.; Levine, Norman; Thompson, Carl I.; Belloni, Francis L.; Recchia, Fabio A.; Ojaimi, Caroline; Kaley, Gabor; Hintze, Thomas H.

    2009-01-01

    As the traditional cardiovascular control laboratory has disappeared from the first-year medical school curriculum, we have recognized the need to develop another "hands-on" experience as a vehicle for wide-ranging discussions of cardiovascular control mechanisms. Using an echocardiograph, an automatic blood pressure cuff, and a reclining bicycle,…

  18. Design, development, test, and evaluation of an automated analytical electrophoresis apparatus

    NASA Technical Reports Server (NTRS)

    Bartels, P. A.; Bier, M.

    1977-01-01

    An Automated Analytical Electrophoresis Apparatus (AAEA) was designed, developed, assembled, and preliminarily tested. The AAEA was demonstrated to be a feasible apparatus for automatically acquiring, displaying, and storing (and eventually analyzing) electrophoresis mobility data from living blood cells. The apparatus and the operation of its major assemblies are described in detail.

  19. Automatic interpretation of ERTS data for forest management

    NASA Technical Reports Server (NTRS)

    Kirvida, L.; Johnson, G. R.

    1973-01-01

    Automatic stratification of forested land from ERTS-1 data provides a valuable tool for resource management. The results are useful for wood product yield estimates, recreation and wild life management, forest inventory and forest condition monitoring. Automatic procedures based on both multi-spectral and spatial features are evaluated. With five classes, training and testing on the same samples, classification accuracy of 74% was achieved using the MSS multispectral features. When adding texture computed from 8 x 8 arrays, classification accuracy of 99% was obtained.

  20. The role of automatic control in future interplanetary spaceflight

    NASA Technical Reports Server (NTRS)

    Scull, J. R.; Moore, J. W.

    1976-01-01

    The paper reviews the guidance and automatic control techniques used in previous U.S. and Soviet lunar and planetary exploration spacecraft, and examines the objectives and requirements of potential future interplanetary missions from the viewpoint of their further demands on automatic control technology. These missions include the Venus orbital imaging radar mission, the Pioneer Mars penetrator mission, the Mars surface sample return mission, Pioneer Saturn/Uranus/Titan probe missions, the Mariner Jupiter orbiter with daughter satellite, and comet and asteroid missions.

  1. A semi-automatic method for quantification and classification of erythrocytes infected with malaria parasites in microscopic images.

    PubMed

    Díaz, Gloria; González, Fabio A; Romero, Eduardo

    2009-04-01

    Visual quantification of parasitemia in thin blood films is a very tedious, subjective and time-consuming task. This study presents an original method for quantification and classification of erythrocytes in stained thin blood films infected with Plasmodium falciparum. The proposed approach is composed of three main phases: a preprocessing step, which corrects luminance differences. A segmentation step that uses the normalized RGB color space for classifying pixels either as erythrocyte or background followed by an Inclusion-Tree representation that structures the pixel information into objects, from which erythrocytes are found. Finally, a two step classification process identifies infected erythrocytes and differentiates the infection stage, using a trained bank of classifiers. Additionally, user intervention is allowed when the approach cannot make a proper decision. Four hundred fifty malaria images were used for training and evaluating the method. Automatic identification of infected erythrocytes showed a specificity of 99.7% and a sensitivity of 94%. The infection stage was determined with an average sensitivity of 78.8% and average specificity of 91.2%.

  2. Factors affecting blood sample haemolysis: a cross-sectional study.

    PubMed

    Barnard, Ed B G; Potter, David L; Ayling, Ruth M; Higginson, Ian; Bailey, Andrew G; Smith, Jason E

    2016-04-01

    To determine the effect of blood sampling through an intravenous catheter compared with a needle in Emergency Department blood sampling. We undertook a prospective, cross-sectional study in a UK university teaching hospital Emergency Department. A convenience sample of 985 patients who required blood sampling via venepuncture was collected. A total of 844 complete sets of data were analysed. The median age was 63 years, and 57% of patients were male. The primary outcome measure was the incidence of haemolysis in blood samples obtained via a needle compared with samples obtained via an intravenous catheter. Secondary outcome measures defined the effect on sample haemolysis of the side of the patient the sample was obtained from, the anatomical location of sampling, the perceived difficulty in obtaining the sample, the order of sample tubes collected, estimated tourniquet time and bench time. Data were analysed with logistic regression, and expressed as odds ratios (95% confidence intervals; P-values). Blood samples obtained through an intravenous catheter were more likely to be haemolysed than those obtained via a needle, odds ratio 5.63 (95% confidence interval 2.49-12.73; P<0.001). Blood sampling via an intravenous catheter was significantly associated with an increase in the likelihood of sample haemolysis compared with sampling with a needle. Wherever practicable, blood samples should be obtained via a needle in preference to an intravenous catheter. Future research should include both an economic evaluation, and staff and patient satisfaction of separating blood sampling and intravenous catheter placement.

  3. A mixture model with a reference-based automatic selection of components for disease classification from protein and/or gene expression levels

    PubMed Central

    2011-01-01

    Background Bioinformatics data analysis is often using linear mixture model representing samples as additive mixture of components. Properly constrained blind matrix factorization methods extract those components using mixture samples only. However, automatic selection of extracted components to be retained for classification analysis remains an open issue. Results The method proposed here is applied to well-studied protein and genomic datasets of ovarian, prostate and colon cancers to extract components for disease prediction. It achieves average sensitivities of: 96.2 (sd = 2.7%), 97.6% (sd = 2.8%) and 90.8% (sd = 5.5%) and average specificities of: 93.6% (sd = 4.1%), 99% (sd = 2.2%) and 79.4% (sd = 9.8%) in 100 independent two-fold cross-validations. Conclusions We propose an additive mixture model of a sample for feature extraction using, in principle, sparseness constrained factorization on a sample-by-sample basis. As opposed to that, existing methods factorize complete dataset simultaneously. The sample model is composed of a reference sample representing control and/or case (disease) groups and a test sample. Each sample is decomposed into two or more components that are selected automatically (without using label information) as control specific, case specific and not differentially expressed (neutral). The number of components is determined by cross-validation. Automatic assignment of features (m/z ratios or genes) to particular component is based on thresholds estimated from each sample directly. Due to the locality of decomposition, the strength of the expression of each feature across the samples can vary. Yet, they will still be allocated to the related disease and/or control specific component. Since label information is not used in the selection process, case and control specific components can be used for classification. That is not the case with standard factorization methods. Moreover, the component selected by proposed method as disease specific can be interpreted as a sub-mode and retained for further analysis to identify potential biomarkers. As opposed to standard matrix factorization methods this can be achieved on a sample (experiment)-by-sample basis. Postulating one or more components with indifferent features enables their removal from disease and control specific components on a sample-by-sample basis. This yields selected components with reduced complexity and generally, it increases prediction accuracy. PMID:22208882

  4. Significantly Reduced Blood Pressure Measurement Variability for Both Normotensive and Hypertensive Subjects: Effect of Polynomial Curve Fitting of Oscillometric Pulses

    PubMed Central

    Zhu, Mingping; Chen, Aiqing

    2017-01-01

    This study aimed to compare within-subject blood pressure (BP) variabilities from different measurement techniques. Cuff pressures from three repeated BP measurements were obtained from 30 normotensive and 30 hypertensive subjects. Automatic BPs were determined from the pulses with normalised peak amplitude larger than a threshold (0.5 for SBP, 0.7 for DBP, and 1.0 for MAP). They were also determined from cuff pressures associated with the above thresholds on a fitted curve polynomial curve of the oscillometric pulse peaks. Finally, the standard deviation (SD) of three repeats and its coefficient of variability (CV) were compared between the two automatic techniques. For the normotensive group, polynomial curve fitting significantly reduced SD of repeats from 3.6 to 2.5 mmHg for SBP and from 3.7 to 2.1 mmHg for MAP and reduced CV from 3.0% to 2.2% for SBP and from 4.3% to 2.4% for MAP (all P < 0.01). For the hypertensive group, SD of repeats decreased from 6.5 to 5.5 mmHg for SBP and from 6.7 to 4.2 mmHg for MAP, and CV decreased from 4.2% to 3.6% for SBP and from 5.8% to 3.8% for MAP (all P < 0.05). In conclusion, polynomial curve fitting of oscillometric pulses had the ability to reduce automatic BP measurement variability. PMID:28785580

  5. Computer Aided Solution for Automatic Segmenting and Measurements of Blood Leucocytes Using Static Microscope Images.

    PubMed

    Abdulhay, Enas; Mohammed, Mazin Abed; Ibrahim, Dheyaa Ahmed; Arunkumar, N; Venkatraman, V

    2018-02-17

    Blood leucocytes segmentation in medical images is viewed as difficult process due to the variability of blood cells concerning their shape and size and the difficulty towards determining location of Blood Leucocytes. Physical analysis of blood tests to recognize leukocytes is tedious, time-consuming and liable to error because of the various morphological components of the cells. Segmentation of medical imagery has been considered as a difficult task because of complexity of images, and also due to the non-availability of leucocytes models which entirely captures the probable shapes in each structures and also incorporate cell overlapping, the expansive variety of the blood cells concerning their shape and size, various elements influencing the outer appearance of the blood leucocytes, and low Static Microscope Image disparity from extra issues outcoming about because of noise. We suggest a strategy towards segmentation of blood leucocytes using static microscope images which is a resultant of three prevailing systems of computer vision fiction: enhancing the image, Support vector machine for segmenting the image, and filtering out non ROI (region of interest) on the basis of Local binary patterns and texture features. Every one of these strategies are modified for blood leucocytes division issue, in this manner the subsequent techniques are very vigorous when compared with its individual segments. Eventually, we assess framework based by compare the outcome and manual division. The findings outcome from this study have shown a new approach that automatically segments the blood leucocytes and identify it from a static microscope images. Initially, the method uses a trainable segmentation procedure and trained support vector machine classifier to accurately identify the position of the ROI. After that, filtering out non ROI have proposed based on histogram analysis to avoid the non ROI and chose the right object. Finally, identify the blood leucocytes type using the texture feature. The performance of the foreseen approach has been tried in appearing differently in relation to the system against manual examination by a gynaecologist utilizing diverse scales. A total of 100 microscope images were used for the comparison, and the results showed that the proposed solution is a viable alternative to the manual segmentation method for accurately determining the ROI. We have evaluated the blood leucocytes identification using the ROI texture (LBP Feature). The identification accuracy in the technique used is about 95.3%., with 100 sensitivity and 91.66% specificity.

  6. Trans-skull ultrasonic Doppler system aided by fuzzy logic

    NASA Astrophysics Data System (ADS)

    Hata, Yutaka; Nakamura, Masato; Yagi, Naomi; Ishikawa, Tomomoto

    2012-06-01

    This paper describes a trans-skull ultrasonic Doppler system for measuring the blood flow direction in brain under skull. In this system, we use an ultrasonic array probe with the center frequency of 1.0 MHz. The system determines the fuzzy degree of blood flow by Doppler Effect, thereby it locates blood vessel. This Doppler Effect is examined by the center of gravity shift of the frequency magnitudes. In in-vitro experiment, a cow bone was employed as the skull, and three silicon tubes were done as blood vessels, and bubble in water as blood. We received the ultrasonic waves through a protein, the skull and silicon tubes in order. In the system, fuzzy degrees are determined with respect to the Doppler shift, amplitude of the waves and attenuation of the tissues. The fuzzy degrees of bone and blood direction are calculated by them. The experimental results showed that the system successfully visualized the skull and flow direction, compared with the location and flow direction of the phantom. Thus, it detected the flow direction by Doppler Effect under skull, and automatically extracted the region of skull and blood vessel.

  7. Machine learning-based in-line holographic sensing of unstained malaria-infected red blood cells.

    PubMed

    Go, Taesik; Kim, Jun H; Byeon, Hyeokjun; Lee, Sang J

    2018-04-19

    Accurate and immediate diagnosis of malaria is important for medication of the infectious disease. Conventional methods for diagnosing malaria are time consuming and rely on the skill of experts. Therefore, an automatic and simple diagnostic modality is essential for healthcare in developing countries that lack the expertise of trained microscopists. In the present study, a new automatic sensing method using digital in-line holographic microscopy (DIHM) combined with machine learning algorithms was proposed to sensitively detect unstained malaria-infected red blood cells (iRBCs). To identify the RBC characteristics, 13 descriptors were extracted from segmented holograms of individual RBCs. Among the 13 descriptors, 10 features were highly statistically different between healthy RBCs (hRBCs) and iRBCs. Six machine learning algorithms were applied to effectively combine the dominant features and to greatly improve the diagnostic capacity of the present method. Among the classification models trained by the 6 tested algorithms, the model trained by the support vector machine (SVM) showed the best accuracy in separating hRBCs and iRBCs for training (n = 280, 96.78%) and testing sets (n = 120, 97.50%). This DIHM-based artificial intelligence methodology is simple and does not require blood staining. Thus, it will be beneficial and valuable in the diagnosis of malaria. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Infrared Cephalic-Vein to Assist Blood Extraction Tasks: Automatic Projection and Recognition

    NASA Astrophysics Data System (ADS)

    Lagüela, S.; Gesto, M.; Riveiro, B.; González-Aguilera, D.

    2017-05-01

    Thermal infrared band is not commonly used in photogrammetric and computer vision algorithms, mainly due to the low spatial resolution of this type of imagery. However, this band captures sub-superficial information, increasing the capabilities of visible bands regarding applications. This fact is especially important in biomedicine and biometrics, allowing the geometric characterization of interior organs and pathologies with photogrammetric principles, as well as the automatic identification and labelling using computer vision algorithms. This paper presents advances of close-range photogrammetry and computer vision applied to thermal infrared imagery, with the final application of Augmented Reality in order to widen its application in the biomedical field. In this case, the thermal infrared image of the arm is acquired and simultaneously projected on the arm, together with the identification label of the cephalic-vein. This way, blood analysts are assisted in finding the vein for blood extraction, especially in those cases where the identification by the human eye is a complex task. Vein recognition is performed based on the Gaussian temperature distribution in the area of the vein, while the calibration between projector and thermographic camera is developed through feature extraction and pattern recognition. The method is validated through its application to a set of volunteers, with different ages and genres, in such way that different conditions of body temperature and vein depth are covered for the applicability and reproducibility of the method.

  9. Large-scale subject-specific cerebral arterial tree modeling using automated parametric mesh generation for blood flow simulation.

    PubMed

    Ghaffari, Mahsa; Tangen, Kevin; Alaraj, Ali; Du, Xinjian; Charbel, Fady T; Linninger, Andreas A

    2017-12-01

    In this paper, we present a novel technique for automatic parametric mesh generation of subject-specific cerebral arterial trees. This technique generates high-quality and anatomically accurate computational meshes for fast blood flow simulations extending the scope of 3D vascular modeling to a large portion of cerebral arterial trees. For this purpose, a parametric meshing procedure was developed to automatically decompose the vascular skeleton, extract geometric features and generate hexahedral meshes using a body-fitted coordinate system that optimally follows the vascular network topology. To validate the anatomical accuracy of the reconstructed vasculature, we performed statistical analysis to quantify the alignment between parametric meshes and raw vascular images using receiver operating characteristic curve. Geometric accuracy evaluation showed an agreement with area under the curves value of 0.87 between the constructed mesh and raw MRA data sets. Parametric meshing yielded on-average, 36.6% and 21.7% orthogonal and equiangular skew quality improvement over the unstructured tetrahedral meshes. The parametric meshing and processing pipeline constitutes an automated technique to reconstruct and simulate blood flow throughout a large portion of the cerebral arterial tree down to the level of pial vessels. This study is the first step towards fast large-scale subject-specific hemodynamic analysis for clinical applications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Motion-aware stroke volume quantification in 4D PC-MRI data of the human aorta.

    PubMed

    Köhler, Benjamin; Preim, Uta; Grothoff, Matthias; Gutberlet, Matthias; Fischbach, Katharina; Preim, Bernhard

    2016-02-01

    4D PC-MRI enables the noninvasive measurement of time-resolved, three-dimensional blood flow data that allow quantification of the hemodynamics. Stroke volumes are essential to assess the cardiac function and evolution of different cardiovascular diseases. The calculation depends on the wall position and vessel orientation, which both change during the cardiac cycle due to the heart muscle contraction and the pumped blood. However, current systems for the quantitative 4D PC-MRI data analysis neglect the dynamic character and instead employ a static 3D vessel approximation. We quantify differences between stroke volumes in the aorta obtained with and without consideration of its dynamics. We describe a method that uses the approximating 3D segmentation to automatically initialize segmentation algorithms that require regions inside and outside the vessel for each temporal position. This enables the use of graph cuts to obtain 4D segmentations, extract vessel surfaces including centerlines for each temporal position and derive motion information. The stroke volume quantification is compared using measuring planes in static (3D) vessels, planes with fixed angulation inside dynamic vessels (this corresponds to the common 2D PC-MRI) and moving planes inside dynamic vessels. Seven datasets with different pathologies such as aneurysms and coarctations were evaluated in close collaboration with radiologists. Compared to the experts' manual stroke volume estimations, motion-aware quantification performs, on average, 1.57% better than calculations without motion consideration. The mean difference between stroke volumes obtained with the different methods is 7.82%. Automatically obtained 4D segmentations overlap by 85.75% with manually generated ones. Incorporating motion information in the stroke volume quantification yields slight but not statistically significant improvements. The presented method is feasible for the clinical routine, since computation times are low and essential parts run fully automatically. The 4D segmentations can be used for other algorithms as well. The simultaneous visualization and quantification may support the understanding and interpretation of cardiac blood flow.

  11. Application of a spectrally filtered probing light beam and RGB decomposition of microphotographs for flow registration of ultrasonically enhanced agglutination of erythrocytes

    NASA Astrophysics Data System (ADS)

    Doubrovski, V. A.; Ganilova, Yu. A.; Zabenkov, I. V.

    2013-08-01

    We propose a development of the flow microscopy method to increase the resolving power upon registration of erythrocyte agglutination. We experimentally show that the action of a ultrasonic standing wave on an agglutinating mixture blood-serum leads to the formation of so large erythrocytic immune complexes that it seems possible to propose a new two-wave optical method of registration of the process of erythrocyte agglutination using the RGB decomposition of microphotographs of the flow of the mixture under study. This approach increases the reliability of registration of erythrocyte agglutination and, consequently, increases the reliability of blood typing. Our results can be used in the development of instruments for automatic human blood typing.

  12. Early physiological markers of cardiovascular risk in community based adolescents with a depressive disorder.

    PubMed

    Waloszek, Joanna M; Byrne, Michelle L; Woods, Michael J; Nicholas, Christian L; Bei, Bei; Murray, Greg; Raniti, Monika; Allen, Nicholas B; Trinder, John

    2015-04-01

    Depression is recognised as an independent cardiovascular risk factor in adults. Identifying this relationship early on in life is potentially important for the prevention of cardiovascular disease (CVD). This study investigated whether clinical depression is associated with multiple physiological markers of CVD risk in adolescents from the general community. Participants aged 12-18 years were recruited from the general community and screened for depressive symptoms. Individuals with high and low depressive symptoms were administered a diagnostic interview. Fifty participants, 25 with a current depressive episode and 25 matched healthy controls, subsequently completed cardiovascular assessments. Variables assessed were automatic brachial and continuous beat-to-beat finger arterial blood pressure, heart rate, vascular functioning by pulse amplitude tonometry following reactive hyperaemia and pulse transit time (PTT) at rest. Blood samples were collected to measure cholesterol, glucose and glycohaemoglobin levels and an index of cumulative risk of traditional cardiovascular risk factors was calculated. Depressed adolescents had a significantly lower reactive hyperaemia index and shorter PTT, suggesting deterioration in vascular integrity and structure. Higher fasting glucose and triglyceride levels were also observed in the depressed group, who also had higher cumulative risk scores indicative of increased engagement in unhealthy behaviours and higher probability of advanced atherosclerotic lesions. The sample size and number of males who completed all cardiovascular measures was small. Clinically depressed adolescents had poorer vascular functioning and increased CVD risk compared to controls, highlighting the need for early identification and intervention for the prevention of CVD in depressed youth. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. 7 CFR 58.227 - Sampling device.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Sampling device. 58.227 Section 58.227 Agriculture....227 Sampling device. If automatic sampling devices are used, they shall be constructed in such a.... The type of sampler and the sampling procedure shall be as approved by the Administrator. ...

  14. 7 CFR 58.227 - Sampling device.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Sampling device. 58.227 Section 58.227 Agriculture....227 Sampling device. If automatic sampling devices are used, they shall be constructed in such a.... The type of sampler and the sampling procedure shall be as approved by the Administrator. ...

  15. Segmentation of white blood cells and comparison of cell morphology by linear and naïve Bayes classifiers.

    PubMed

    Prinyakupt, Jaroonrut; Pluempitiwiriyawej, Charnchai

    2015-06-30

    Blood smear microscopic images are routinely investigated by haematologists to diagnose most blood diseases. However, the task is quite tedious and time consuming. An automatic detection and classification of white blood cells within such images can accelerate the process tremendously. In this paper we propose a system to locate white blood cells within microscopic blood smear images, segment them into nucleus and cytoplasm regions, extract suitable features and finally, classify them into five types: basophil, eosinophil, neutrophil, lymphocyte and monocyte. Two sets of blood smear images were used in this study's experiments. Dataset 1, collected from Rangsit University, were normal peripheral blood slides under light microscope with 100× magnification; 555 images with 601 white blood cells were captured by a Nikon DS-Fi2 high-definition color camera and saved in JPG format of size 960 × 1,280 pixels at 15 pixels per 1 μm resolution. In dataset 2, 477 cropped white blood cell images were downloaded from CellaVision.com. They are in JPG format of size 360 × 363 pixels. The resolution is estimated to be 10 pixels per 1 μm. The proposed system comprises a pre-processing step, nucleus segmentation, cell segmentation, feature extraction, feature selection and classification. The main concept of the segmentation algorithm employed uses white blood cell's morphological properties and the calibrated size of a real cell relative to image resolution. The segmentation process combined thresholding, morphological operation and ellipse curve fitting. Consequently, several features were extracted from the segmented nucleus and cytoplasm regions. Prominent features were then chosen by a greedy search algorithm called sequential forward selection. Finally, with a set of selected prominent features, both linear and naïve Bayes classifiers were applied for performance comparison. This system was tested on normal peripheral blood smear slide images from two datasets. Two sets of comparison were performed: segmentation and classification. The automatically segmented results were compared to the ones obtained manually by a haematologist. It was found that the proposed method is consistent and coherent in both datasets, with dice similarity of 98.9 and 91.6% for average segmented nucleus and cell regions, respectively. Furthermore, the overall correction rate in the classification phase is about 98 and 94% for linear and naïve Bayes models, respectively. The proposed system, based on normal white blood cell morphology and its characteristics, was applied to two different datasets. The results of the calibrated segmentation process on both datasets are fast, robust, efficient and coherent. Meanwhile, the classification of normal white blood cells into five types shows high sensitivity in both linear and naïve Bayes models, with slightly better results in the linear classifier.

  16. Automatic counting and classification of bacterial colonies using hyperspectral imaging

    USDA-ARS?s Scientific Manuscript database

    Detection and counting of bacterial colonies on agar plates is a routine microbiology practice to get a rough estimate of the number of viable cells in a sample. There have been a variety of different automatic colony counting systems and software algorithms mainly based on color or gray-scale pictu...

  17. Exposure to Violent Video Games Increases Automatic Aggressiveness

    ERIC Educational Resources Information Center

    Uhlmann, Eric; Swanson, Jane

    2004-01-01

    The effects of exposure to violent video games on automatic associations with the self were investigated in a sample of 121 students. Playing the violent video game Doom led participants to associate themselves with aggressive traits and actions on the Implicit Association Test. In addition, self-reported prior exposure to violent video games…

  18. Investigating Prompt Difficulty in an Automatically Scored Speaking Performance Assessment

    ERIC Educational Resources Information Center

    Cox, Troy L.

    2013-01-01

    Speaking assessments for second language learners have traditionally been expensive to administer because of the cost of rating the speech samples. To reduce the cost, many researchers are investigating the potential of using automatic speech recognition (ASR) as a means to score examinee responses to open-ended prompts. This study examined the…

  19. An automated atmospheric sampling system operating on 747 airliners

    NASA Technical Reports Server (NTRS)

    Perkins, P.; Gustafsson, U. R. C.

    1975-01-01

    An air sampling system that automatically measures the temporal and spatial distribution of selected particulate and gaseous constituents of the atmosphere has been installed on a number of commercial airliners and is collecting data on commercial air routes covering the world. Measurements of constituents related to aircraft engine emissions and other pollutants are made in the upper troposphere and lower stratosphere (6 to 12 km) in support of the Global Air Sampling Program (GASP). Aircraft operated by different airlines sample air at latitudes from the Arctic to Australia. This system includes specialized instrumentation for measuring carbon monoxide, ozone, water vapor, and particulates, a special air inlet probe for sampling outside air, a computerized automatic control, and a data acquisition system. Air constituents and related flight data are tape recorded in flight for later computer processing on the ground.

  20. Fully automatic characterization and data collection from crystals of biological macromolecules.

    PubMed

    Svensson, Olof; Malbet-Monaco, Stéphanie; Popov, Alexander; Nurizzo, Didier; Bowler, Matthew W

    2015-08-01

    Considerable effort is dedicated to evaluating macromolecular crystals at synchrotron sources, even for well established and robust systems. Much of this work is repetitive, and the time spent could be better invested in the interpretation of the results. In order to decrease the need for manual intervention in the most repetitive steps of structural biology projects, initial screening and data collection, a fully automatic system has been developed to mount, locate, centre to the optimal diffraction volume, characterize and, if possible, collect data from multiple cryocooled crystals. Using the capabilities of pixel-array detectors, the system is as fast as a human operator, taking an average of 6 min per sample depending on the sample size and the level of characterization required. Using a fast X-ray-based routine, samples are located and centred systematically at the position of highest diffraction signal and important parameters for sample characterization, such as flux, beam size and crystal volume, are automatically taken into account, ensuring the calculation of optimal data-collection strategies. The system is now in operation at the new ESRF beamline MASSIF-1 and has been used by both industrial and academic users for many different sample types, including crystals of less than 20 µm in the smallest dimension. To date, over 8000 samples have been evaluated on MASSIF-1 without any human intervention.

  1. Test of a potential link between analytic and nonanalytic category learning and automatic, effortful processing.

    PubMed

    Tracy, J I; Pinsk, M; Helverson, J; Urban, G; Dietz, T; Smith, D J

    2001-08-01

    The link between automatic and effortful processing and nonanalytic and analytic category learning was evaluated in a sample of 29 college undergraduates using declarative memory, semantic category search, and pseudoword categorization tasks. Automatic and effortful processing measures were hypothesized to be associated with nonanalytic and analytic categorization, respectively. Results suggested that contrary to prediction strong criterion-attribute (analytic) responding on the pseudoword categorization task was associated with strong automatic, implicit memory encoding of frequency-of-occurrence information. Data are discussed in terms of the possibility that criterion-attribute category knowledge, once established, may be expressed with few attentional resources. The data indicate that attention resource requirements, even for the same stimuli and task, vary depending on the category rule system utilized. Also, the automaticity emerging from familiarity with analytic category exemplars is very different from the automaticity arising from extensive practice on a semantic category search task. The data do not support any simple mapping of analytic and nonanalytic forms of category learning onto the automatic and effortful processing dichotomy and challenge simple models of brain asymmetries for such procedures. Copyright 2001 Academic Press.

  2. Automatic segmentation of male pelvic anatomy on computed tomography images: a comparison with multiple observers in the context of a multicentre clinical trial.

    PubMed

    Geraghty, John P; Grogan, Garry; Ebert, Martin A

    2013-04-30

    This study investigates the variation in segmentation of several pelvic anatomical structures on computed tomography (CT) between multiple observers and a commercial automatic segmentation method, in the context of quality assurance and evaluation during a multicentre clinical trial. CT scans of two prostate cancer patients ('benchmarking cases'), one high risk (HR) and one intermediate risk (IR), were sent to multiple radiotherapy centres for segmentation of prostate, rectum and bladder structures according to the TROG 03.04 "RADAR" trial protocol definitions. The same structures were automatically segmented using iPlan software for the same two patients, allowing structures defined by automatic segmentation to be quantitatively compared with those defined by multiple observers. A sample of twenty trial patient datasets were also used to automatically generate anatomical structures for quantitative comparison with structures defined by individual observers for the same datasets. There was considerable agreement amongst all observers and automatic segmentation of the benchmarking cases for bladder (mean spatial variations < 0.4 cm across the majority of image slices). Although there was some variation in interpretation of the superior-inferior (cranio-caudal) extent of rectum, human-observer contours were typically within a mean 0.6 cm of automatically-defined contours. Prostate structures were more consistent for the HR case than the IR case with all human observers segmenting a prostate with considerably more volume (mean +113.3%) than that automatically segmented. Similar results were seen across the twenty sample datasets, with disagreement between iPlan and observers dominant at the prostatic apex and superior part of the rectum, which is consistent with observations made during quality assurance reviews during the trial. This study has demonstrated quantitative analysis for comparison of multi-observer segmentation studies. For automatic segmentation algorithms based on image-registration as in iPlan, it is apparent that agreement between observer and automatic segmentation will be a function of patient-specific image characteristics, particularly for anatomy with poor contrast definition. For this reason, it is suggested that automatic registration based on transformation of a single reference dataset adds a significant systematic bias to the resulting volumes and their use in the context of a multicentre trial should be carefully considered.

  3. Voices from "The Front": How Student Violence Is Changing the Experience of School Leaders

    ERIC Educational Resources Information Center

    McAdams, Charles R., III; Foster, Victoria A.

    2008-01-01

    The nature of student violence in America's schools has changed over the past two decades. Research suggests that there are two distinct kinds or "subtypes" of aggression in youth-reactive aggression and proactive aggression. Reactive aggression is characterized as a "hot-blooded," automatic, defensive response to immediate and often misperceived…

  4. Automatic Control of Veno-Venous Extracorporeal Lung Assist.

    PubMed

    Kopp, Ruedger; Bensberg, Ralf; Stollenwerk, Andre; Arens, Jutta; Grottke, Oliver; Walter, Marian; Rossaint, Rolf

    2016-10-01

    Veno-venous extracorporeal lung assist (ECLA) can provide sufficient gas exchange even in most severe cases of acute respiratory distress syndrome. Commercially available systems are manually controlled, although an automatically controlled ECLA could allow individualized and continuous adaption to clinical requirements. Therefore, we developed a demonstrator with an integrated control algorithm to keep continuously measured peripheral oxygen saturation and partial pressure of carbon dioxide constant by automatically adjusting extracorporeal blood and gas flow. The "SmartECLA" system was tested in six animal experiments with increasing pulmonary hypoventilation and hypoxic inspiratory gas mixture to simulate progressive acute respiratory failure. During a cumulative evaluation time of 32 h for all experiments, automatic ECLA control resulted in a peripheral oxygen saturation ≥90% for 98% of the time with the lowest value of 82% for 15 s. Partial pressure of venous carbon dioxide was between 40 and 49 mm Hg for 97% of the time with no value <35 mm Hg or >49 mm Hg. With decreasing inspiratory oxygen concentration, extracorporeal oxygen uptake increased from 68 ± 25 to 154 ± 34 mL/min (P < 0.05), and reducing respiratory rate resulted in increasing extracorporeal carbon dioxide elimination from 71 ± 37 to 92 ± 37 mL/min (P < 0.05). The "SmartECLA" demonstrator allowed reliable automatic control of the extracorporeal circuit. Proof of concept could be demonstrated for this novel automatically controlled veno-venous ECLA circuit. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  5. Automated branching pattern report generation for laparoscopic surgery assistance

    NASA Astrophysics Data System (ADS)

    Oda, Masahiro; Matsuzaki, Tetsuro; Hayashi, Yuichiro; Kitasaka, Takayuki; Misawa, Kazunari; Mori, Kensaku

    2015-05-01

    This paper presents a method for generating branching pattern reports of abdominal blood vessels for laparoscopic gastrectomy. In gastrectomy, it is very important to understand branching structure of abdominal arteries and veins, which feed and drain specific abdominal organs including the stomach, the liver and the pancreas. In the real clinical stage, a surgeon creates a diagnostic report of the patient anatomy. This report summarizes the branching patterns of the blood vessels related to the stomach. The surgeon decides actual operative procedure. This paper shows an automated method to generate a branching pattern report for abdominal blood vessels based on automated anatomical labeling. The report contains 3D rendering showing important blood vessels and descriptions of branching patterns of each vessel. We have applied this method for fifty cases of 3D abdominal CT scans and confirmed the proposed method can automatically generate branching pattern reports of abdominal arteries.

  6. Hemolysis associated with pneumatic tube system transport for blood samples

    PubMed Central

    Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih

    2014-01-01

    Objective: The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Methods: Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. Results: The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Conclusion: Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis. PMID:24639830

  7. An Adaptive Monitoring Scheme for Automatic Control of Anaesthesia in dynamic surgical environments based on Bispectral Index and Blood Pressure.

    PubMed

    Yu, Yu-Ning; Doctor, Faiyaz; Fan, Shou-Zen; Shieh, Jiann-Shing

    2018-04-13

    During surgical procedures, bispectral index (BIS) is a well-known measure used to determine the patient's depth of anesthesia (DOA). However, BIS readings can be subject to interference from many factors during surgery, and other parameters such as blood pressure (BP) and heart rate (HR) can provide more stable indicators. However, anesthesiologist still consider BIS as a primary measure to determine if the patient is correctly anaesthetized while relaying on the other physiological parameters to monitor and ensure the patient's status is maintained. The automatic control of administering anesthesia using intelligent control systems has been the subject of recent research in order to alleviate the burden on the anesthetist to manually adjust drug dosage in response physiological changes for sustaining DOA. A system proposed for the automatic control of anesthesia based on type-2 Self Organizing Fuzzy Logic Controllers (T2-SOFLCs) has been shown to be effective in the control of DOA under simulated scenarios while contending with uncertainties due to signal noise and dynamic changes in pharmacodynamics (PD) and pharmacokinetic (PK) effects of the drug on the body. This study considers both BIS and BP as part of an adaptive automatic control scheme, which can adjust to the monitoring of either parameter in response to changes in the availability and reliability of BIS signals during surgery. The simulation of different control schemes using BIS data obtained during real surgical procedures to emulate noise and interference factors have been conducted. The use of either or both combined parameters for controlling the delivery Propofol to maintain safe target set points for DOA are evaluated. The results show that combing BIS and BP based on the proposed adaptive control scheme can ensure the target set points and the correct amount of drug in the body is maintained even with the intermittent loss of BIS signal that could otherwise disrupt an automated control system.

  8. Automatic identification of informative regions with epigenomic changes associated to hematopoiesis

    PubMed Central

    Carrillo-de-Santa-Pau, Enrique; Pancaldi, Vera; Were, Felipe; Martin-Subero, Ignacio

    2017-01-01

    Abstract Hematopoiesis is one of the best characterized biological systems but the connection between chromatin changes and lineage differentiation is not yet well understood. We have developed a bioinformatic workflow to generate a chromatin space that allows to classify 42 human healthy blood epigenomes from the BLUEPRINT, NIH ROADMAP and ENCODE consortia by their cell type. This approach let us to distinguish different cells types based on their epigenomic profiles, thus recapitulating important aspects of human hematopoiesis. The analysis of the orthogonal dimension of the chromatin space identify 32,662 chromatin determinant regions (CDRs), genomic regions with different epigenetic characteristics between the cell types. Functional analysis revealed that these regions are linked with cell identities. The inclusion of leukemia epigenomes in the healthy hematological chromatin sample space gives us insights on the healthy cell types that are more epigenetically similar to the disease samples. Further analysis of tumoral epigenetic alterations in hematopoietic CDRs points to sets of genes that are tightly regulated in leukemic transformations and commonly mutated in other tumors. Our method provides an analytical approach to study the relationship between epigenomic changes and cell lineage differentiation. Method availability: https://github.com/david-juan/ChromDet. PMID:28934481

  9. Automatic photointerpretation for plant species and stress identification (ERTS-A1)

    NASA Technical Reports Server (NTRS)

    Swanlund, G. D. (Principal Investigator); Kirvida, L.; Johnson, G. R.

    1973-01-01

    The author has identified the following significant results. Automatic stratification of forested land from ERTS-1 data provides a valuable tool for resource management. The results are useful for wood product yield estimates, recreation and wildlife management, forest inventory, and forest condition monitoring. Automatic procedures based on both multispectral and spatial features are evaluated. With five classes, training and testing on the same samples, classification accuracy of 74 percent was achieved using the MSS multispectral features. When adding texture computed from 8 x 8 arrays, classification accuracy of 90 percent was obtained.

  10. AUTOMATIC COUNTING APPARATUS

    DOEpatents

    Howell, W.D.

    1957-08-20

    An apparatus for automatically recording the results of counting operations on trains of electrical pulses is described. The disadvantages of prior devices utilizing the two common methods of obtaining the count rate are overcome by this apparatus; in the case of time controlled operation, the disclosed system automatically records amy information stored by the scaler but not transferred to the printer at the end of the predetermined time controlled operations and, in the case of count controlled operation, provision is made to prevent a weak sample from occupying the apparatus for an excessively long period of time.

  11. [Evaluation of Medical Instruments Cleaning Effect of Fluorescence Detection Technique].

    PubMed

    Sheng, Nan; Shen, Yue; Li, Zhen; Li, Huijuan; Zhou, Chaoqun

    2016-01-01

    To compare the cleaning effect of automatic cleaning machine and manual cleaning on coupling type surgical instruments. A total of 32 cleaned medical instruments were randomly sampled from medical institutions in Putuo District medical institutions disinfection supply center. Hygiena System SUREII ATP was used to monitor the ATP value, and the cleaning effect was evaluated. The surface ATP values of the medical instrument of manual cleaning were higher than that of the automatic cleaning machine. Coupling type surgical instruments has better cleaning effect of automatic cleaning machine before disinfection, the application is recommended.

  12. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    DOEpatents

    Burtis, C.A.; Johnson, W.F.; Walker, W.A.

    1985-08-05

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.

  13. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    DOEpatents

    Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.

    1988-01-01

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.

  14. Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros.

    PubMed

    Rovie-Ryan, Jeffrine Japning; Zainuddin, Zainal Zahari; Marni, Wahap; Ahmad, Abdul Hamid; Ambu, Laurentius N; Payne, Junaidi

    2013-02-01

    To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA(®) blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair follicles and blood samples from the rhinoceros and subjecting it to the same laboratory process. BLAST search and constructed phylogenetic trees confirmed the blood meal samples were indeed from the rhino. This method could be used in the field application to noninvasively collect genetic samples. Collection of tabanids and other haematophagous arthropods (e.g. mosquitoes and ticks) and other blood-sucking parasites (e.g. leeches and worms) could also provide information on vector-borne diseases.

  15. RNA-Stabilized Whole Blood Samples but Not Peripheral Blood Mononuclear Cells Can Be Stored for Prolonged Time Periods Prior to Transcriptome Analysis

    PubMed Central

    Debey-Pascher, Svenja; Hofmann, Andrea; Kreusch, Fatima; Schuler, Gerold; Schuler-Thurner, Beatrice; Schultze, Joachim L.; Staratschek-Jox, Andrea

    2011-01-01

    Microarray-based transcriptome analysis of peripheral blood as surrogate tissue has become an important approach in clinical implementations. However, application of gene expression profiling in routine clinical settings requires careful consideration of the influence of sample handling and RNA isolation methods on gene expression profile outcome. We evaluated the effect of different sample preservation strategies (eg, cryopreservation of peripheral blood mononuclear cells or freezing of PAXgene-stabilized whole blood samples) on gene expression profiles. Expression profiles obtained from cryopreserved peripheral blood mononuclear cells differed substantially from those of their nonfrozen counterpart samples. Furthermore, expression profiles in cryopreserved peripheral blood mononuclear cell samples were found to undergo significant alterations with increasing storage period, whereas long-term freezing of PAXgene RNA stabilized whole blood samples did not significantly affect stability of gene expression profiles. This report describes important technical aspects contributing toward the establishment of robust and reliable guidance for gene expression studies using peripheral blood and provides a promising strategy for reliable implementation in routine handling for diagnostic purposes. PMID:21704280

  16. Automatic differential analysis of NMR experiments in complex samples.

    PubMed

    Margueritte, Laure; Markov, Petar; Chiron, Lionel; Starck, Jean-Philippe; Vonthron-Sénécheau, Catherine; Bourjot, Mélanie; Delsuc, Marc-André

    2018-06-01

    Liquid state nuclear magnetic resonance (NMR) is a powerful tool for the analysis of complex mixtures of unknown molecules. This capacity has been used in many analytical approaches: metabolomics, identification of active compounds in natural extracts, and characterization of species, and such studies require the acquisition of many diverse NMR measurements on series of samples. Although acquisition can easily be performed automatically, the number of NMR experiments involved in these studies increases very rapidly, and this data avalanche requires to resort to automatic processing and analysis. We present here a program that allows the autonomous, unsupervised processing of a large corpus of 1D, 2D, and diffusion-ordered spectroscopy experiments from a series of samples acquired in different conditions. The program provides all the signal processing steps, as well as peak-picking and bucketing of 1D and 2D spectra, the program and its components are fully available. In an experiment mimicking the search of a bioactive species in a natural extract, we use it for the automatic detection of small amounts of artemisinin added to a series of plant extracts and for the generation of the spectral fingerprint of this molecule. This program called Plasmodesma is a novel tool that should be useful to decipher complex mixtures, particularly in the discovery of biologically active natural products from plants extracts but can also in drug discovery or metabolomics studies. Copyright © 2017 John Wiley & Sons, Ltd.

  17. [Microbiological testing of the artificial gingival margin in dentures].

    PubMed

    Hermann, Péter; Klein, Ildikó; Barna, Zsuzsanna; Kaán, Miklós; Fejérdy, Pál

    2004-06-01

    In everyday practice dental laboratories try to reproduce the natural form of sulcus gingivae at the transitional area between artificial teeth and gingiva of removable dentures, even on esthetically less important areas. Aim of these investigations were to examine how artificial recreation of the sulcus gingivae influences plaque retention, and what is the microbiological relevance of these. Investigations were carried out on the vestibular side of removable dentures of 32 randomly selected patients treated at the Department of Prosthodontics at the Faculty of Dentistry, Semmelweis University. Microbiological samples were taken from each patient using the same method. Samples were taken from the left upper first molars' artificial gingival margin using sterile paper points. Paper points were then transported in Eppendorf-tubes, in 2 ml of physiological saline solution, and processed within a two-hour period of time. Series dilutions were made of the sample solutions, then surface-streaked on Subaraud and Gentamycin, blood-agar, eosin-methylene blue and Mitis Salivarius culture enriched with Bacitracin. Subaraud culture was induced under aerob conditions, at room temperature for two days, then the total amount of fungi quantified. After pure-culturing Candida albicans ID-culture was used for identification, and BioMerieux ATB automatic equipment to identify different Candida species. From pure cultures identification was carried out with Gram-staining, Neisser-staining, catalase, oxidase and also with other biochemical reactions. Blood-agar was used to determine total germ count, and normal commensal pharyngeal and oral bacteria. After collecting the microbiological samples, the conventional shape of the dental margin of gingiva was abolished on one side of the dentures and a smooth transition was created between denture teeth and the artificial gingiva in the molar and premolar region. During our investigations only blastomycetes were found. Besides most common Candida albicans, Candida glabrata, tropicallis, spherica and lambica were also identified. Our patients did not miss artificial sulcus gingivae, had no aesthetic complaints about smooth transition between artificial teeth and gingiva. Microbiological investigations of the samples and the comparative analysis showed, that on the smooth transitional areas compared to conventionally shaped sulci significantly less gram-negative, gram-positive bacteria and oral fungi were found, and there was no plaque formation.

  18. Miltenberger blood group typing by real-time polymerase chain reaction (qPCR) melting curve analysis in Thai population.

    PubMed

    Vongsakulyanon, A; Kitpoka, P; Kunakorn, M; Srikhirin, T

    2015-12-01

    To develop reliable and convenient methods for Miltenberger (Mi(a) ) blood group typing. To apply real-time polymerase chain reaction (qPCR) melting curve analysis to Mi(a) blood group typing. The Mi(a) blood group is the collective set of glycophorin hybrids in the MNS blood group system. Mi(a+) blood is common among East Asians and is also found in the Thai population. Incompatible Mi(a) blood transfusions pose the risk of life-threatening haemolysis; therefore, Mi(a) blood group typing is necessary in ethnicities where the Mi(a) blood group is prevalent. One hundred and forty-three blood samples from Thai blood donors were used in the study. The samples included 50 Mi(a+) samples and 93 Mi(a-) samples, which were defined by serology. The samples were typed by Mi(a) typing qPCR, and 50 Mi(a+) samples were sequenced to identify the Mi(a) subtypes. Mi(a) subtyping qPCR was performed to define GP.Mur. Both Mi(a) typing and Mi(a) subtyping were tested on a conventional PCR platform. The results of Mi(a) typing qPCR were all concordant with serology. Sequencing of the 50 Mi(a+) samples revealed 47 GP.Mur samples and 3 GP.Hop or Bun samples. Mi(a) subtyping qPCR was the supplementary test used to further define GP.Mur from other Mi(a) subtypes. Both Mi(a) typing and Mi(a) subtyping performed well using a conventional PCR platform. Mi(a) typing qPCR correctly identified Mi(a) blood groups in a Thai population with the feasibility of Mi(a) subtype discrimination, and Mi(a) subtyping qPCR was able to further define GP.Mur from other Mi(a) subtypes. © 2015 British Blood Transfusion Society.

  19. Image classification of unlabeled malaria parasites in red blood cells.

    PubMed

    Zheng Zhang; Ong, L L Sharon; Kong Fang; Matthew, Athul; Dauwels, Justin; Ming Dao; Asada, Harry

    2016-08-01

    This paper presents a method to detect unlabeled malaria parasites in red blood cells. The current "gold standard" for malaria diagnosis is microscopic examination of thick blood smear, a time consuming process requiring extensive training. Our goal is to develop an automate process to identify malaria infected red blood cells. Major issues in automated analysis of microscopy images of unstained blood smears include overlapping cells and oddly shaped cells. Our approach creates robust templates to detect infected and uninfected red cells. Histogram of Oriented Gradients (HOGs) features are extracted from templates and used to train a classifier offline. Next, the ViolaJones object detection framework is applied to detect infected and uninfected red cells and the image background. Results show our approach out-performs classification approaches with PCA features by 50% and cell detection algorithms applying Hough transforms by 24%. Majority of related work are designed to automatically detect stained parasites in blood smears where the cells are fixed. Although it is more challenging to design algorithms for unstained parasites, our methods will allow analysis of parasite progression in live cells under different drug treatments.

  20. A blood pressure monitor with robust noise reduction system under linear cuff inflation and deflation.

    PubMed

    Usuda, Takashi; Kobayashi, Naoki; Takeda, Sunao; Kotake, Yoshifumi

    2010-01-01

    We have developed the non-invasive blood pressure monitor which can measure the blood pressure quickly and robustly. This monitor combines two measurement mode: the linear inflation and the linear deflation. On the inflation mode, we realized a faster measurement with rapid inflation rate. On the deflation mode, we realized a robust noise reduction. When there is neither noise nor arrhythmia, the inflation mode incorporated on this monitor provides precise, quick and comfortable measurement. Once the inflation mode fails to calculate appropriate blood pressure due to body movement or arrhythmia, then the monitor switches automatically to the deflation mode and measure blood pressure by using digital signal processing as wavelet analysis, filter bank, filter combined with FFT and Inverse FFT. The inflation mode succeeded 2440 measurements out of 3099 measurements (79%) in an operating room and a rehabilitation room. The new designed blood pressure monitor provides the fastest measurement for patient with normal circulation and robust measurement for patients with body movement or severe arrhythmia. Also this fast measurement method provides comfortableness for patients.

  1. Computerized video-enhanced high temporal resolution of erythrocytes sedimentation rate (ESR-graphy) reveals complex dynamic and self-organizing properties of whole blood

    NASA Astrophysics Data System (ADS)

    Voeikov, Vladimir L.; Kondakov, Sergey E.; Buravleva, Ekaterina; Kaganovsky, Isaak; Reznikov, Mikhail

    2000-05-01

    An automatic device for high-temporal resolution of the process of red blood sedimentation was designed. The position of the boundary between red blood and plasma may be registered each 30 sec in several pipettes simultaneously with +/- 10 mkm precision. Fractional rates of the boundary movement are deduced with high accuracy. Data are processed by a PC and presented as velocity-time curves (ESR-grams) and the curves describing time evolution of the boundary position. Several unexpected phenomena in the process of red blood sedimentation have been revealed. Upward fast movements of the boundary up to 1 mm were noted. In patients' blood sets of 5 - 10 milliHz oscillations of sedimentation rate were usually developing at early stages of blood sedimentation. In non-diluted healthy donors' blood high amplitude periodic oscillations were either absent, or were emerging only after blood resided in pipettes for several hours. When blood was diluted to a certain degree with physiological saline or with own plasma long-term low frequency (1 - 3 milliHz) rate oscillations regularly appeared. Non-trivial dependence of patterns of ESR-grams on diluting of blood with own plasma or saline was observed. Thus, non-linear dynamic behavior of living blood has been revealed due to application of the principles of the system of technical vision for the detailed analysis of red blood sedimentation kinetics.

  2. Automatic Method of Pause Measurement for Normal and Dysarthric Speech

    ERIC Educational Resources Information Center

    Rosen, Kristin; Murdoch, Bruce; Folker, Joanne; Vogel, Adam; Cahill, Louise; Delatycki, Martin; Corben, Louise

    2010-01-01

    This study proposes an automatic method for the detection of pauses and identification of pause types in conversational speech for the purpose of measuring the effects of Friedreich's Ataxia (FRDA) on speech. Speech samples of [approximately] 3 minutes were recorded from 13 speakers with FRDA and 18 healthy controls. Pauses were measured from the…

  3. 40 CFR 98.7 - What standardized methods are incorporated by reference into this part?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 2005) Standard Practice for Automatic Sampling of Petroleum and Petroleum Products, IBR approved for... from Railroad Cars, Barges, Trucks, or Stockpiles, IBR approved for § 98.164(b). (35) ASTM D7430-08ae1... Liquids—Automatic pipeline sampling—Second Edition 1988-12-01, IBR approved for § 98.164(b). (3) [Reserved...

  4. Improvement of Handwriting Automaticity among Children Treated for Graphomotor Difficulties over a Period of Six Months

    ERIC Educational Resources Information Center

    Wicki, Werner; Hurschler Lichtsteiner, Sibylle

    2018-01-01

    Although fluency and automaticity of handwriting have been recognized as important research topics for 30 years, empirical data on respective developmental courses among typically developing children as well as clinical samples have remained very limited. To fill this gap, this study investigates the development of handwriting automaticity…

  5. Comparison of the image-derived radioactivity and blood-sample radioactivity for estimating the clinical indicators of the efficacy of boron neutron capture therapy (BNCT): 4-borono-2-18F-fluoro-phenylalanine (FBPA) PET study.

    PubMed

    Isohashi, Kayako; Shimosegawa, Eku; Naka, Sadahiro; Kanai, Yasukazu; Horitsugi, Genki; Mochida, Ikuko; Matsunaga, Keiko; Watabe, Tadashi; Kato, Hiroki; Tatsumi, Mitsuaki; Hatazawa, Jun

    2016-12-01

    In boron neutron capture therapy (BNCT), positron emission tomography (PET) with 4-borono-2- 18 F-fluoro-phenylalanine (FBPA) is the only method to estimate an accumulation of 10 B to target tumor and surrounding normal tissue after administering 10 B carrier of L-paraboronophenylalanine and to search the indication of BNCT for individual patient. Absolute concentration of 10 B in tumor has been estimated by multiplying 10 B concentration in blood during BNCT by tumor to blood radioactivity (T/B) ratio derived from FBPA PET. However, the method to measure blood radioactivity either by blood sampling or image data has not been standardized. We compared image-derived blood radioactivity of FBPA with blood sampling data and studied appropriate timing and location for measuring image-derived blood counts. We obtained 7 repeated whole-body PET scans in five healthy subjects. Arterialized venous blood samples were obtained from the antecubital vein, heated in a heating blanket. Time-activity curves (TACs) of image-derived blood radioactivity were obtained using volumes of interest (VOIs) over ascending aorta, aortic arch, pulmonary artery, left and right ventricles, inferior vena cava, and abdominal aorta. Image-derived blood radioactivity was compared with those measured by blood sampling data in each location. Both the TACs of blood sampling radioactivity in each subject, and the TACs of image-derived blood radioactivity showed a peak within 5 min after the tracer injection, and promptly decreased soon thereafter. Linear relationship was found between blood sampling radioactivity and image-derived blood radioactivity in all the VOIs at any timing of data sampling (p < 0.001). Image-derived radioactivity measured in the left and right ventricles 30 min after injection showed high correlation with blood radioactivity. Image-derived blood radioactivity was lower than blood sampling radioactivity data by 20 %. Reduction of blood radioactivity of FBPA in left ventricle after 30 min of FBPA injection was minimal. We conclude that the image-derived T/B ratio can be reliably used by setting the VOI on the left ventricle at 30 min after FBPA administration and correcting for underestimation due to partial volume effect and reduction of FBPA blood radioactivity.

  6. Optimization and automation of quantitative NMR data extraction.

    PubMed

    Bernstein, Michael A; Sýkora, Stan; Peng, Chen; Barba, Agustín; Cobas, Carlos

    2013-06-18

    NMR is routinely used to quantitate chemical species. The necessary experimental procedures to acquire quantitative data are well-known, but relatively little attention has been applied to data processing and analysis. We describe here a robust expert system that can be used to automatically choose the best signals in a sample for overall concentration determination and determine analyte concentration using all accepted methods. The algorithm is based on the complete deconvolution of the spectrum which makes it tolerant of cases where signals are very close to one another and includes robust methods for the automatic classification of NMR resonances and molecule-to-spectrum multiplets assignments. With the functionality in place and optimized, it is then a relatively simple matter to apply the same workflow to data in a fully automatic way. The procedure is desirable for both its inherent performance and applicability to NMR data acquired for very large sample sets.

  7. Pse-Analysis: a python package for DNA/RNA and protein/ peptide sequence analysis based on pseudo components and kernel methods.

    PubMed

    Liu, Bin; Wu, Hao; Zhang, Deyuan; Wang, Xiaolong; Chou, Kuo-Chen

    2017-02-21

    To expedite the pace in conducting genome/proteome analysis, we have developed a Python package called Pse-Analysis. The powerful package can automatically complete the following five procedures: (1) sample feature extraction, (2) optimal parameter selection, (3) model training, (4) cross validation, and (5) evaluating prediction quality. All the work a user needs to do is to input a benchmark dataset along with the query biological sequences concerned. Based on the benchmark dataset, Pse-Analysis will automatically construct an ideal predictor, followed by yielding the predicted results for the submitted query samples. All the aforementioned tedious jobs can be automatically done by the computer. Moreover, the multiprocessing technique was adopted to enhance computational speed by about 6 folds. The Pse-Analysis Python package is freely accessible to the public at http://bioinformatics.hitsz.edu.cn/Pse-Analysis/, and can be directly run on Windows, Linux, and Unix.

  8. Automatic computational labeling of glomerular textural boundaries

    NASA Astrophysics Data System (ADS)

    Ginley, Brandon; Tomaszewski, John E.; Sarder, Pinaki

    2017-03-01

    The glomerulus, a specialized bundle of capillaries, is the blood filtering unit of the kidney. Each human kidney contains about 1 million glomeruli. Structural damages in the glomerular micro-compartments give rise to several renal conditions; most severe of which is proteinuria, where excessive blood proteins flow freely to the urine. The sole way to confirm glomerular structural damage in renal pathology is by examining histopathological or immunofluorescence stained needle biopsies under a light microscope. However, this method is extremely tedious and time consuming, and requires manual scoring on the number and volume of structures. Computational quantification of equivalent features promises to greatly ease this manual burden. The largest obstacle to computational quantification of renal tissue is the ability to recognize complex glomerular textural boundaries automatically. Here we present a computational pipeline to accurately identify glomerular boundaries with high precision and accuracy. The computational pipeline employs an integrated approach composed of Gabor filtering, Gaussian blurring, statistical F-testing, and distance transform, and performs significantly better than standard Gabor based textural segmentation method. Our integrated approach provides mean accuracy/precision of 0.89/0.97 on n = 200Hematoxylin and Eosin (HE) glomerulus images, and mean 0.88/0.94 accuracy/precision on n = 200 Periodic Acid Schiff (PAS) glomerulus images. Respective accuracy/precision of the Gabor filter bank based method is 0.83/0.84 for HE and 0.78/0.8 for PAS. Our method will simplify computational partitioning of glomerular micro-compartments hidden within dense textural boundaries. Automatic quantification of glomeruli will streamline structural analysis in clinic, and can help realize real time diagnoses and interventions.

  9. Poster — Thur Eve — 70: Automatic lung bronchial and vessel bifurcations detection algorithm for deformable image registration assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Labine, Alexandre; Carrier, Jean-François; Bedwani, Stéphane

    2014-08-15

    Purpose: To investigate an automatic bronchial and vessel bifurcations detection algorithm for deformable image registration (DIR) assessment to improve lung cancer radiation treatment. Methods: 4DCT datasets were acquired and exported to Varian treatment planning system (TPS) EclipseTM for contouring. The lungs TPS contour was used as the prior shape for a segmentation algorithm based on hierarchical surface deformation that identifies the deformed lungs volumes of the 10 breathing phases. Hounsfield unit (HU) threshold filter was applied within the segmented lung volumes to identify blood vessels and airways. Segmented blood vessels and airways were skeletonised using a hierarchical curve-skeleton algorithm basedmore » on a generalized potential field approach. A graph representation of the computed skeleton was generated to assign one of three labels to each node: the termination node, the continuation node or the branching node. Results: 320 ± 51 bifurcations were detected in the right lung of a patient for the 10 breathing phases. The bifurcations were visually analyzed. 92 ± 10 bifurcations were found in the upper half of the lung and 228 ± 45 bifurcations were found in the lower half of the lung. Discrepancies between ten vessel trees were mainly ascribed to large deformation and in regions where the HU varies. Conclusions: We established an automatic method for DIR assessment using the morphological information of the patient anatomy. This approach allows a description of the lung's internal structure movement, which is needed to validate the DIR deformation fields for accurate 4D cancer treatment planning.« less

  10. System automatically supplies precise analytical samples of high-pressure gases

    NASA Technical Reports Server (NTRS)

    Langdon, W. M.

    1967-01-01

    High-pressure-reducing and flow-stabilization system delivers analytical gas samples from a gas supply. The system employs parallel capillary restrictors for pressure reduction and downstream throttling valves for flow control. It is used in conjunction with a sampling valve and minimizes alterations of the sampled gas.

  11. Sampling Error in a Particulate Mixture: An Analytical Chemistry Experiment.

    ERIC Educational Resources Information Center

    Kratochvil, Byron

    1980-01-01

    Presents an undergraduate experiment demonstrating sampling error. Selected as the sampling system is a mixture of potassium hydrogen phthalate and sucrose; using a self-zeroing, automatically refillable buret to minimize titration time of multiple samples and employing a dilute back-titrant to obtain high end-point precision. (CS)

  12. Automatic scoring of dicentric chromosomes as a tool in large scale radiation accidents.

    PubMed

    Romm, H; Ainsbury, E; Barnard, S; Barrios, L; Barquinero, J F; Beinke, C; Deperas, M; Gregoire, E; Koivistoinen, A; Lindholm, C; Moquet, J; Oestreicher, U; Puig, R; Rothkamm, K; Sommer, S; Thierens, H; Vandersickel, V; Vral, A; Wojcik, A

    2013-08-30

    Mass casualty scenarios of radiation exposure require high throughput biological dosimetry techniques for population triage in order to rapidly identify individuals who require clinical treatment. The manual dicentric assay is a highly suitable technique, but it is also very time consuming and requires well trained scorers. In the framework of the MULTIBIODOSE EU FP7 project, semi-automated dicentric scoring has been established in six European biodosimetry laboratories. Whole blood was irradiated with a Co-60 gamma source resulting in 8 different doses between 0 and 4.5Gy and then shipped to the six participating laboratories. To investigate two different scoring strategies, cell cultures were set up with short term (2-3h) or long term (24h) colcemid treatment. Three classifiers for automatic dicentric detection were applied, two of which were developed specifically for these two different culture techniques. The automation procedure included metaphase finding, capture of cells at high resolution and detection of dicentric candidates. The automatically detected dicentric candidates were then evaluated by a trained human scorer, which led to the term 'semi-automated' being applied to the analysis. The six participating laboratories established at least one semi-automated calibration curve each, using the appropriate classifier for their colcemid treatment time. There was no significant difference between the calibration curves established, regardless of the classifier used. The ratio of false positive to true positive dicentric candidates was dose dependent. The total staff effort required for analysing 150 metaphases using the semi-automated approach was 2 min as opposed to 60 min for manual scoring of 50 metaphases. Semi-automated dicentric scoring is a useful tool in a large scale radiation accident as it enables high throughput screening of samples for fast triage of potentially exposed individuals. Furthermore, the results from the participating laboratories were comparable which supports networking between laboratories for this assay. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Automatic sampling and analysis of organics and biomolecules by capillary action-supported contactless atmospheric pressure ionization mass spectrometry.

    PubMed

    Hsieh, Cheng-Huan; Meher, Anil Kumar; Chen, Yu-Chie

    2013-01-01

    Contactless atmospheric pressure ionization (C-API) method has been recently developed for mass spectrometric analysis. A tapered capillary is used as both the sampling tube and spray emitter in C-API. No electric contact is required on the capillary tip during C-API mass spectrometric analysis. The simple design of the ionization method enables the automation of the C-API sampling system. In this study, we propose an automatic C-API sampling system consisting of a capillary (∼1 cm), an aluminium sample holder, and a movable XY stage for the mass spectrometric analysis of organics and biomolecules. The aluminium sample holder is controlled by the movable XY stage. The outlet of the C-API capillary is placed in front of the orifice of a mass spectrometer, whereas the sample well on the sample holder is moved underneath the capillary inlet. The sample droplet on the well can be readily infused into the C-API capillary through capillary action. When the sample solution reaches the capillary outlet, the sample spray is readily formed in the proximity of the mass spectrometer applied with a high electric field. The gas phase ions generated from the spray can be readily monitored by the mass spectrometer. We demonstrate that six samples can be analyzed in sequence within 3.5 min using this automatic C-API MS setup. Furthermore, the well containing the rinsing solvent is alternately arranged between the sample wells. Therefore, the C-API capillary could be readily flushed between runs. No carryover problems are observed during the analyses. The sample volume required for the C-API MS analysis is minimal, with less than 1 nL of the sample solution being sufficient for analysis. The feasibility of using this setup for quantitative analysis is also demonstrated.

  14. Spectral feature characterization methods for blood stain detection in crime scene backgrounds

    NASA Astrophysics Data System (ADS)

    Yang, Jie; Mathew, Jobin J.; Dube, Roger R.; Messinger, David W.

    2016-05-01

    Blood stains are one of the most important types of evidence for forensic investigation. They contain valuable DNA information, and the pattern of the stains can suggest specifics about the nature of the violence that transpired at the scene. Blood spectral signatures containing unique reflectance or absorption features are important both for forensic on-site investigation and laboratory testing. They can be used for target detection and identification applied to crime scene hyperspectral imagery, and also be utilized to analyze the spectral variation of blood on various backgrounds. Non-blood stains often mislead the detection and can generate false alarms at a real crime scene, especially for dark and red backgrounds. This paper measured the reflectance of liquid blood and 9 kinds of non-blood samples in the range of 350 nm - 2500 nm in various crime scene backgrounds, such as pure samples contained in petri dish with various thicknesses, mixed samples with different colors and materials of fabrics, and mixed samples with wood, all of which are examined to provide sub-visual evidence for detecting and recognizing blood from non-blood samples in a realistic crime scene. The spectral difference between blood and non-blood samples are examined and spectral features such as "peaks" and "depths" of reflectance are selected. Two blood stain detection methods are proposed in this paper. The first method uses index to denote the ratio of "depth" minus "peak" over"depth" add"peak" within a wavelength range of the reflectance spectrum. The second method uses relative band depth of the selected wavelength ranges of the reflectance spectrum. Results show that the index method is able to discriminate blood from non-blood samples in most tested crime scene backgrounds, but is not able to detect it from black felt. Whereas the relative band depth method is able to discriminate blood from non-blood samples on all of the tested background material types and colors.

  15. Automatic bio-sample bacteria detection system

    NASA Technical Reports Server (NTRS)

    Chappelle, E. W.; Colburn, M.; Kelbaugh, B. N.; Picciolo, G. L.

    1971-01-01

    Electromechanical device analyzes urine specimens in 15 minutes and processes one sample per minute. Instrument utilizes bioluminescent reaction between luciferase-luciferin mixture and adenosine triphosphate (ATP) to determine number of bacteria present in the sample. Device has potential application to analysis of other body fluids.

  16. Real-time automatic registration in optical surgical navigation

    NASA Astrophysics Data System (ADS)

    Lin, Qinyong; Yang, Rongqian; Cai, Ken; Si, Xuan; Chen, Xiuwen; Wu, Xiaoming

    2016-05-01

    An image-guided surgical navigation system requires the improvement of the patient-to-image registration time to enhance the convenience of the registration procedure. A critical step in achieving this aim is performing a fully automatic patient-to-image registration. This study reports on a design of custom fiducial markers and the performance of a real-time automatic patient-to-image registration method using these markers on the basis of an optical tracking system for rigid anatomy. The custom fiducial markers are designed to be automatically localized in both patient and image spaces. An automatic localization method is performed by registering a point cloud sampled from the three dimensional (3D) pedestal model surface of a fiducial marker to each pedestal of fiducial markers searched in image space. A head phantom is constructed to estimate the performance of the real-time automatic registration method under four fiducial configurations. The head phantom experimental results demonstrate that the real-time automatic registration method is more convenient, rapid, and accurate than the manual method. The time required for each registration is approximately 0.1 s. The automatic localization method precisely localizes the fiducial markers in image space. The averaged target registration error for the four configurations is approximately 0.7 mm. The automatic registration performance is independent of the positions relative to the tracking system and the movement of the patient during the operation.

  17. The preanalytical optimization of blood cultures: a review and the clinical importance of benchmarking in 5 Belgian hospitals.

    PubMed

    Willems, Elise; Smismans, Annick; Cartuyvels, Reinoud; Coppens, Guy; Van Vaerenbergh, Kristien; Van den Abeele, Anne-Marie; Frans, Johan

    2012-05-01

    Bloodstream infections remain a major challenge in medicine. Optimal detection of pathogens is only possible if the quality of preanalytical factors is thoroughly controlled. Since the laboratory is responsible for this preanalytical phase, the quality control of critical factors should be integrated in its quality control program. The numerous recommendations regarding blood culture collection contain controversies. Only an unambiguous guideline permits standardization and interlaboratory quality control. We present an evidence-based concise guideline of critical preanalytical determinants for blood culture collection and summarize key performance indicators with their concomitant target values. In an attempt to benchmark, we compared the true-positive rate, contamination rate, and collected blood volume of blood culture bottles in 5 Belgian hospital laboratories. The true-positive blood culture rate fell within previously defined acceptation criteria by Baron et al. (2005) in all 5 hospitals, whereas the contamination rate exceeded the target value in 4 locations. Most unexpected, in each of the 5 laboratories, more than one third of the blood culture bottles were incorrectly filled, irrespective of the manufacturer of the blood culture vials. As a consequence of this shortcoming, one manufacturer recently developed an automatic blood volume monitoring system. In conclusion, clear recommendations for standardized blood culture collection combined with quality control of critical factors of the preanalytical phase are essential for diagnostic blood culture improvement. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Computer aided solution for segmenting the neuron line in hippocampal microscope images

    NASA Astrophysics Data System (ADS)

    Albaidhani, Tahseen; Jassim, Sabah; Al-Assam, Hisham

    2017-05-01

    The brain Hippocampus component is known to be responsible for memory and spatial navigation. Its functionality depends on the status of different blood vessels within the Hippocampus and is severely impaired by Alzheimer's disease as a result blockage of increasing number of blood vessels by accumulation of amyloid-beta (Aβ) protein. Accurate counting of blood vessels within the Hippocampus of mice brain, from microscopic images, is an active research area for the understanding of Alzheimer's disease. Here, we report our work on automatic detection of the Region of Interest, i.e. the region in which blood vessels are located. This area typically falls between the hippocampus edge and the line of neurons within the Hippocampus. This paper proposes a new method to detect and exclude the neuron line to improve the accuracy of blood vessel counting because some neurons on it might lead to false positive cases as they look like blood vessels. Our proposed solution is based on using trainable segmentation approach with morphological operations, taking into account variation in colour, intensity values, and image texture. Experiments on a sufficient number of microscopy images of mouse brain demonstrate the effectiveness of the developed solution in preparation for blood vessels counting.

  19. Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros

    PubMed Central

    Rovie-Ryan, Jeffrine Japning; Zainuddin, Zainal Zahari; Marni, Wahap; Ahmad, Abdul Hamid; Ambu, Laurentius N.; Payne, Junaidi

    2013-01-01

    Objective To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Methods Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA® blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair follicles and blood samples from the rhinoceros and subjecting it to the same laboratory process. Results BLAST search and constructed phylogenetic trees confirmed the blood meal samples were indeed from the rhino. Conclusions This method could be used in the field application to noninvasively collect genetic samples. Collection of tabanids and other haematophagous arthropods (e.g. mosquitoes and ticks) and other blood-sucking parasites (e.g. leeches and worms) could also provide information on vector-borne diseases. PMID:23593586

  20. Validity Evidence of the Spanish Version of the Automatic Thoughts Questionnaire-8 in Colombia.

    PubMed

    Ruiz, Francisco J; Suárez-Falcón, Juan C; Riaño-Hernández, Diana

    2017-02-13

    The Automatic Thoughts Questionnaire (ATQ) is a widely used, 30-item, 5-point Likert-type scale that measures the frequency of negative automatic thoughts as experienced by individuals suffering from depression. However, there is some controversy about the factor structure of the ATQ, and its application can be too time-consuming for survey research. Accordingly, an abbreviated, 8-item version of the ATQ has been proposed. The aim of this study was to analyze the validity evidence of the Spanish version of the ATQ-8 in Colombia. The ATQ-8 was administered to a total of 1587 participants, including a sample of undergraduates, one of general population, and a clinical sample. The internal consistency across the different samples was good (α = .89). The one-factor model found in the original scale showed a good fit to the data (RMSEA = .083, 90% CI [.074, .092]; CFI = .96; NNFI = .95). The clinical sample's mean score on the ATQ-8 was significantly higher than the scores of the nonclinical samples. The ATQ-8 was sensitive to the effects of a 1-session acceptance and commitment therapy focused on disrupting negative repetitive thinking. ATQ-8 scores were significantly related to dysfunctional schemas, emotional symptoms, mindfulness, experiential avoidance, satisfaction with life, and dysfunctional attitudes. In conclusion, the Spanish version of the ATQ-8 showed good psychometric properties in Colombia.

  1. Combined radiogrammetry and texture analysis for early diagnosis of osteoporosis using Indian and Swiss data.

    PubMed

    Areeckal, Anu Shaju; Kamath, Jagannath; Zawadynski, Sophie; Kocher, Michel; S, Sumam David

    2018-05-26

    Osteoporosis is a bone disorder characterized by bone loss and decreased bone strength. The most widely used technique for detection of osteoporosis is the measurement of bone mineral density (BMD) using dual energy X-ray absorptiometry (DXA). But DXA scans are expensive and not widely available in low-income economies. In this paper, we propose a low cost pre-screening tool for the detection of low bone mass, using cortical radiogrammetry of third metacarpal bone and trabecular texture analysis of distal radius from hand and wrist radiographs. An automatic segmentation algorithm to automatically locate and segment the third metacarpal bone and distal radius region of interest (ROI) is proposed. Cortical measurements such as combined cortical thickness (CCT), cortical area (CA), percent cortical area (PCA) and Barnett Nordin index (BNI) were taken from the shaft of third metacarpal bone. Texture analysis of trabecular network at the distal radius was performed using features obtained from histogram, gray level Co-occurrence matrix (GLCM) and morphological gradient method (MGM). The significant cortical and texture features were selected using independent sample t-test and used to train classifiers to classify healthy subjects and people with low bone mass. The proposed pre-screening tool was validated on two ethnic groups, Indian sample population and Swiss sample population. Data of 134 subjects from Indian sample population and 65 subjects from Swiss sample population were analysed. The proposed automatic segmentation approach shows a detection accuracy of 86% in detecting the third metacarpal bone shaft and 90% in accurately locating the distal radius ROI. Comparison of the automatic radiogrammetry to the ground truth provided by experts show a mean absolute error of 0.04 mm for cortical width of healthy group, 0.12 mm for cortical width of low bone mass group, 0.22 mm for medullary width of healthy group, and 0.26 mm for medullary width of low bone mass group. Independent sample t-test was used to select the most discriminant features, to be used as input for training the classifiers. Pearson correlation analysis of the extracted features with DXA-BMD of lumbar spine (DXA-LS) shows significantly high correlation values. Classifiers were trained with the most significant features in the Indian and Swiss sample data. Weighted KNN classifier shows the best test accuracy of 78% for Indian sample data and 100% for Swiss sample data. Hence, combined automatic radiogrammetry and texture analysis is shown to be an effective low cost pre-screening tool for early diagnosis of osteoporosis. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Temperatures kept cool in Southampton.

    PubMed

    McDonald, Katey

    2010-03-01

    According to Digitron, hospitals countrywide are seeing the benefits of DigiTrak, the company's automatic wireless temperature monitoring system. Katey McDonald, the company's marketing manager, outlines how the system replaces traditional methods of data collection by providing a single networked package, and describes its use at Southampton General Hospital for blood monitoring, with the help of advanced biomedical scientist and quality officer there Marie Cundall.

  3. Cardiac variation of inferior vena cava: new concept in the evaluation of intravascular blood volume.

    PubMed

    Nakamura, Kensuke; Tomida, Makoto; Ando, Takehiro; Sen, Kon; Inokuchi, Ryota; Kobayashi, Etsuko; Nakajima, Susumu; Sakuma, Ichiro; Yahagi, Naoki

    2013-07-01

    Evaluation of the intravascular blood volume is an important assessment in emergency and critical care medicine. Measurement of the inferior vena cava (IVC) respiratory variation by ultrasound echography is useful, but it entails subjective problems. We have hypothesized that IVC cardiac variation is also correlated with intravascular blood volume and analyzed it automatically using computer software of two kinds, later comparing the results. Snakes, software to track boundaries by curve line continuity, and template matching software were incorporated into a computer with an ultrasound machine to track the short-axis view of IVC automatically and analyze it with approximation by ellipse. Eight healthy volunteers with temporary mild hypovolemia underwent echography before and after passive leg raising and while wearing medical anti-shock trousers. IVC cardiac variation was visually decreased by both leg raising and medical anti-shock trousers. The collapse index (maximum - minimum/maximum) of area during three cardiac beats was decreased showing a good relationship to fluid load simulations; 0.24 ± 0.03 at baseline versus 0.11 ± 0.01 with leg raising and 0.12 ± 0.01 with medical anti-shock trousers. In conclusion, IVC cardiac variation has the potential to provide an evaluation of water volume. It presents some advantages in mechanical analysis over respiratory variation. At the very least, we need to exercise some caution with cardiac variation when evaluating respiratory variation.

  4. Cannula Tip With Integrated Volume Sensor for Rotary Blood Pump Control: Early-Stage Development.

    PubMed

    Cysyk, Joshua; Newswanger, Ray; Popjes, Eric; Pae, Walter; Jhun, Choon-Sik; Izer, Jenelle; Weiss, William; Rosenberg, Gerson

    2018-05-10

    The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip for cf-LVADs with integrated electrodes for volume sensing based on conductance. Four platinum-iridium ring electrodes were installed into grooves on a cannula body constructed from polyetheretherketone (PEEK). A sinusoidal current excitation waveform (250 μA pk-pk, 50 kHz) was applied across one pair of electrodes, and the conductance-dependent voltage was sensed across the second pair of electrodes. The conductance catheter was tested in an acute ovine model (n = 3) in conjunction with the HeartMate II rotary blood pump to provide circulatory support and unload the ventricle. Echocardiography was used to measure ventricular size during pump support for verification for the conductance measurements. The conductance measurements correlated linearly with the echocardiography dimension measurements more than the full range of pump support from minimum support to suction. This cannula tip will enable the development of automatic control systems to optimize pump support based on a real-time measurement of ventricular size.

  5. Automatic segmentation of the left ventricle cavity and myocardium in MRI data.

    PubMed

    Lynch, M; Ghita, O; Whelan, P F

    2006-04-01

    A novel approach for the automatic segmentation has been developed to extract the epi-cardium and endo-cardium boundaries of the left ventricle (lv) of the heart. The developed segmentation scheme takes multi-slice and multi-phase magnetic resonance (MR) images of the heart, transversing the short-axis length from the base to the apex. Each image is taken at one instance in the heart's phase. The images are segmented using a diffusion-based filter followed by an unsupervised clustering technique and the resulting labels are checked to locate the (lv) cavity. From cardiac anatomy, the closest pool of blood to the lv cavity is the right ventricle cavity. The wall between these two blood-pools (interventricular septum) is measured to give an approximate thickness for the myocardium. This value is used when a radial search is performed on a gradient image to find appropriate robust segments of the epi-cardium boundary. The robust edge segments are then joined using a normal spline curve. Experimental results are presented with very encouraging qualitative and quantitative results and a comparison is made against the state-of-the art level-sets method.

  6. Automatic detection of ischemic stroke based on scaling exponent electroencephalogram using extreme learning machine

    NASA Astrophysics Data System (ADS)

    Adhi, H. A.; Wijaya, S. K.; Prawito; Badri, C.; Rezal, M.

    2017-03-01

    Stroke is one of cerebrovascular diseases caused by the obstruction of blood flow to the brain. Stroke becomes the leading cause of death in Indonesia and the second in the world. Stroke also causes of the disability. Ischemic stroke accounts for most of all stroke cases. Obstruction of blood flow can cause tissue damage which results the electrical changes in the brain that can be observed through the electroencephalogram (EEG). In this study, we presented the results of automatic detection of ischemic stroke and normal subjects based on the scaling exponent EEG obtained through detrended fluctuation analysis (DFA) using extreme learning machine (ELM) as the classifier. The signal processing was performed with 18 channels of EEG in the range of 0-30 Hz. Scaling exponents of the subjects were used as the input for ELM to classify the ischemic stroke. The performance of detection was observed by the value of accuracy, sensitivity and specificity. The result showed, performance of the proposed method to classify the ischemic stroke was 84 % for accuracy, 82 % for sensitivity and 87 % for specificity with 120 hidden neurons and sine as the activation function of ELM.

  7. Quantitative Analysis of Heavy Metals in Water Based on LIBS with an Automatic Device for Sample Preparation

    NASA Astrophysics Data System (ADS)

    Hu, Li; Zhao, Nanjing; Liu, Wenqing; Meng, Deshuo; Fang, Li; Wang, Yin; Yu, Yang; Ma, Mingjun

    2015-08-01

    Heavy metals in water can be deposited on graphite flakes, which can be used as an enrichment method for laser-induced breakdown spectroscopy (LIBS) and is studied in this paper. The graphite samples were prepared with an automatic device, which was composed of a loading and unloading module, a quantitatively adding solution module, a rapid heating and drying module and a precise rotating module. The experimental results showed that the sample preparation methods had no significant effect on sample distribution and the LIBS signal accumulated in 20 pulses was stable and repeatable. With an increasing amount of the sample solution on the graphite flake, the peak intensity at Cu I 324.75 nm accorded with the exponential function with a correlation coefficient of 0.9963 and the background intensity remained unchanged. The limit of detection (LOD) was calculated through linear fitting of the peak intensity versus the concentration. The LOD decreased rapidly with an increasing amount of sample solution until the amount exceeded 20 mL and the correlation coefficient of exponential function fitting was 0.991. The LOD of Pb, Ni, Cd, Cr and Zn after evaporating different amounts of sample solution on the graphite flakes was measured and the variation tendency of their LOD with sample solution amounts was similar to the tendency for Cu. The experimental data and conclusions could provide a reference for automatic sample preparation and heavy metal in situ detection. supported by National Natural Science Foundation of China (No. 60908018), National High Technology Research and Development Program of China (No. 2013AA065502) and Anhui Province Outstanding Youth Science Fund of China (No. 1108085J19)

  8. Random sampling technique for ultra-fast computations of molecular opacities for exoplanet atmospheres

    NASA Astrophysics Data System (ADS)

    Min, M.

    2017-10-01

    Context. Opacities of molecules in exoplanet atmospheres rely on increasingly detailed line-lists for these molecules. The line lists available today contain for many species up to several billions of lines. Computation of the spectral line profile created by pressure and temperature broadening, the Voigt profile, of all of these lines is becoming a computational challenge. Aims: We aim to create a method to compute the Voigt profile in a way that automatically focusses the computation time into the strongest lines, while still maintaining the continuum contribution of the high number of weaker lines. Methods: Here, we outline a statistical line sampling technique that samples the Voigt profile quickly and with high accuracy. The number of samples is adjusted to the strength of the line and the local spectral line density. This automatically provides high accuracy line shapes for strong lines or lines that are spectrally isolated. The line sampling technique automatically preserves the integrated line opacity for all lines, thereby also providing the continuum opacity created by the large number of weak lines at very low computational cost. Results: The line sampling technique is tested for accuracy when computing line spectra and correlated-k tables. Extremely fast computations ( 3.5 × 105 lines per second per core on a standard current day desktop computer) with high accuracy (≤1% almost everywhere) are obtained. A detailed recipe on how to perform the computations is given.

  9. Automated spectrophotometric bicarbonate analysis in duodenal juice compared to the back titration method.

    PubMed

    Erchinger, Friedemann; Engjom, Trond; Gudbrandsen, Oddrun Anita; Tjora, Erling; Gilja, Odd H; Dimcevski, Georg

    2016-01-01

    We have recently evaluated a short endoscopic secretin test for exocrine pancreatic function. Bicarbonate concentration in duodenal juice is an important parameter in this test. Measurement of bicarbonate by back titration as the gold standard method is time consuming, expensive and technically difficult, thus a simplified method is warranted. We aimed to evaluate an automated spectrophotometric method in samples spanning the effective range of bicarbonate concentrations in duodenal juice. We also evaluated if freezing of samples before analyses would affect its results. Patients routinely examined with short endoscopic secretin test suspected to have decreased pancreatic function of various reasons were included. Bicarbonate in duodenal juice was quantified by back titration and automatic spectrophotometry. Both fresh and thawed samples were analysed spectrophotometrically. 177 samples from 71 patients were analysed. Correlation coefficient of all measurements was r = 0.98 (p < 0.001). Correlation coefficient of fresh versus frozen samples conducted with automatic spectrophotometry (n = 25): r = 0.96 (p < 0.001) CONCLUSIONS: The measurement of bicarbonate in fresh and thawed samples by automatic spectrophotometrical analysis correlates excellent with the back titration gold standard. This is a major simplification of direct pancreas function testing, and allows a wider distribution of bicarbonate testing in duodenal juice. Extreme values for Bicarbonate concentration achieved by the autoanalyser method have to be interpreted with caution. Copyright © 2016 IAP and EPC. Published by Elsevier India Pvt Ltd. All rights reserved.

  10. A healthy volunteer study to investigate trace element contamination of blood samples by stainless steel venepuncture needles.

    PubMed

    Hodnett, Darragh; Wood, David M; Raja, Kishor; Dargan, Paul I; Shah, Anoop D

    2012-02-01

    The trace elements cobalt (Co), chromium (Cr), manganese (Mn) and nickel (Ni) are normally present at low concentrations in blood. There has been a concern that stainless steel venepuncture needles typically used for collection of blood samples may contaminate these samples, leading to the masking of deficiency states or causing potential clinical confusion as to whether an individual has a "toxic" concentration. To determine whether there is any difference between the concentrations of the trace elements obtained by different methods of blood sampling. We took blood samples using a standard venepuncture needle, a "butterfly" winged infusion needle (three consecutive samples) and a plastic intravenous cannula (three consecutive samples) from 10 healthy volunteers. We measured the concentrations of Co, Cr, Mn and Ni in the samples using Inductively Coupled Plasma Mass Spectrometry, and used analysis of variance (ANOVA) to investigate if there was any difference between the methods of blood sampling. The mean ± standard deviation blood metal concentrations were: Co 0.33 ± 0.2 μg/l, Cr 2.43 ± 1.55 μg/l, Mn 8.07 ± 7.74 μg/l and Ni 10.4 ± 4.69 μg/l. There was considerable variation between blood metal concentrations of individual subjects and a few sporadic high values. By ANOVA, there was no significant difference between the metal concentrations measured using different methods of blood collection. It is not necessary to routinely use a plastic cannula for blood sampling for trace element analysis. However, it is possible that sporadic contamination due to stainless steel needles may occur, so we would recommend that unexpected high concentrations are verified by taking a second sample taken through a plastic cannula.

  11. A system for real-time measurement of the brachial artery diameter in B-mode ultrasound images.

    PubMed

    Gemignani, Vincenzo; Faita, Francesco; Ghiadoni, Lorenzo; Poggianti, Elisa; Demi, Marcello

    2007-03-01

    The measurement of the brachial artery diameter is frequently used in clinical studies for evaluating the flow-mediated dilation and, in conjunction with the blood pressure value, for assessing arterial stiffness. This paper presents a system for computing the brachial artery diameter in real-time by analyzing B-mode ultrasound images. The method is based on a robust edge detection algorithm which is used to automatically locate the two walls of the vessel. The measure of the diameter is obtained with subpixel precision and with a temporal resolution of 25 samples/s, so that the small dilations induced by the cardiac cycle can also be retrieved. The algorithm is implemented on a standalone video processing board which acquires the analog video signal from the ultrasound equipment. Results are shown in real-time on a graphical user interface. The system was tested both on synthetic ultrasound images and in clinical studies of flow-mediated dilation. Accuracy, robustness, and intra/inter observer variability of the method were evaluated.

  12. An Investigation on Micro-Raman Spectra and Wavelet Data Analysis for Pemphigus Vulgaris Follow-up Monitoring.

    PubMed

    Camerlingo, Carlo; Zenone, Flora; Perna, Giuseppe; Capozzi, Vito; Cirillo, Nicola; Gaeta, Giovanni Maria; Lepore, Maria

    2008-06-01

    A wavelet multi-component decomposition algorithm has been used for data analysis of micro-Raman spectra of blood serum samples from patients affected by pemphigus vulgaris at different stages. Pemphigus is a chronic, autoimmune, blistering disease of the skin and mucous membranes with a potentially fatal outcome. Spectra were measured by means of a Raman confocal microspectrometer apparatus using the 632.8 nm line of a He-Ne laser source. A discrete wavelet transform decomposition method has been applied to the recorded Raman spectra in order to overcome problems related to low-level signals and the presence of noise and background components due to light scattering and fluorescence. This numerical data treatment can automatically extract quantitative information from the Raman spectra and makes more reliable the data comparison. Even if an exhaustive investigation has not been done in this work, the feasibility of the follow-up monitoring of pemphigus vulgaris pathology has been clearly proved with useful implications for the clinical applications.

  13. An Investigation on Micro-Raman Spectra and Wavelet Data Analysis for Pemphigus Vulgaris Follow-up Monitoring

    PubMed Central

    Camerlingo, Carlo; Zenone, Flora; Perna, Giuseppe; Capozzi, Vito; Cirillo, Nicola; Gaeta, Giovanni Maria; Lepore, Maria

    2008-01-01

    A wavelet multi-component decomposition algorithm has been used for data analysis of micro-Raman spectra of blood serum samples from patients affected by pemphigus vulgaris at different stages. Pemphigus is a chronic, autoimmune, blistering disease of the skin and mucous membranes with a potentially fatal outcome. Spectra were measured by means of a Raman confocal microspectrometer apparatus using the 632.8 nm line of a He-Ne laser source. A discrete wavelet transform decomposition method has been applied to the recorded Raman spectra in order to overcome problems related to low-level signals and the presence of noise and background components due to light scattering and fluorescence. This numerical data treatment can automatically extract quantitative information from the Raman spectra and makes more reliable the data comparison. Even if an exhaustive investigation has not been done in this work, the feasibility of the follow-up monitoring of pemphigus vulgaris pathology has been clearly proved with useful implications for the clinical applications. PMID:27879899

  14. Enhancing the Automatic Generation of Hints with Expert Seeding

    ERIC Educational Resources Information Center

    Stamper, John; Barnes, Tiffany; Croy, Marvin

    2011-01-01

    The Hint Factory is an implementation of our novel method to automatically generate hints using past student data for a logic tutor. One disadvantage of the Hint Factory is the time needed to gather enough data on new problems in order to provide hints. In this paper we describe the use of expert sample solutions to "seed" the hint generation…

  15. Assessing Children's Home Language Environments Using Automatic Speech Recognition Technology

    ERIC Educational Resources Information Center

    Greenwood, Charles R.; Thiemann-Bourque, Kathy; Walker, Dale; Buzhardt, Jay; Gilkerson, Jill

    2011-01-01

    The purpose of this research was to replicate and extend some of the findings of Hart and Risley using automatic speech processing instead of human transcription of language samples. The long-term goal of this work is to make the current approach to speech processing possible by researchers and clinicians working on a daily basis with families and…

  16. Infrared Spectroscopy of Blood for Disease Identification

    NASA Astrophysics Data System (ADS)

    Pichardo, J. L.; Huerta-Franco, R.; Álvarez, R. R.; Bernal, J.; Gutiérrez-Juárez, G.; Palomares-Anda, P.

    2003-09-01

    Total reflectance attenuated infrared Fourier transform spectroscopy was used to analyze blood samples. Plasma and red blood cells were separated by centrifugation. The spectra were recorded from 200 to 4000 cm-1 under the same conditions for all samples. Samples of healthy donors were compared with those patients with different diseases (polycythemia and high blood pressure). Patients were under medical control at the time of the study. However, the preliminary results reveal that blood samples from healthy subjects had different infrared spectra compared to the non healthy patients.

  17. Cognitive tasks promote automatization of postural control in young and older adults.

    PubMed

    Potvin-Desrochers, Alexandra; Richer, Natalie; Lajoie, Yves

    2017-09-01

    Researchers looking at the effects of performing a concurrent cognitive task on postural control in young and older adults using traditional center-of-pressure measures and complexity measures found discordant results. Results of experiments showing improvements of stability have suggested the use of strategies such as automatization of postural control or stiffening strategy. This experiment aimed to confirm in healthy young and older adults that performing a cognitive task while standing leads to improvements that are due to automaticity of sway by using sample entropy. Twenty-one young adults and twenty-five older adults were asked to stand on a force platform while performing a cognitive task. There were four cognitive tasks: simple reaction time, go/no-go reaction time, equation and occurrence of a digit in a number sequence. Results demonstrated decreased sway area and variability as well as increased sample entropy for both groups when performing a cognitive task. Results suggest that performing a concurrent cognitive task promotes the adoption of an automatic postural control in young and older adults as evidenced by an increased postural stability and postural sway complexity. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Establishing a novel automated magnetic bead-based method for the extraction of DNA from a variety of forensic samples.

    PubMed

    Witt, Sebastian; Neumann, Jan; Zierdt, Holger; Gébel, Gabriella; Röscheisen, Christiane

    2012-09-01

    Automated systems have been increasingly utilized for DNA extraction by many forensic laboratories to handle growing numbers of forensic casework samples while minimizing the risk of human errors and assuring high reproducibility. The step towards automation however is not easy: The automated extraction method has to be very versatile to reliably prepare high yields of pure genomic DNA from a broad variety of sample types on different carrier materials. To prevent possible cross-contamination of samples or the loss of DNA, the components of the kit have to be designed in a way that allows for the automated handling of the samples with no manual intervention necessary. DNA extraction using paramagnetic particles coated with a DNA-binding surface is predestined for an automated approach. For this study, we tested different DNA extraction kits using DNA-binding paramagnetic particles with regard to DNA yield and handling by a Freedom EVO(®)150 extraction robot (Tecan) equipped with a Te-MagS magnetic separator. Among others, the extraction kits tested were the ChargeSwitch(®)Forensic DNA Purification Kit (Invitrogen), the PrepFiler™Automated Forensic DNA Extraction Kit (Applied Biosystems) and NucleoMag™96 Trace (Macherey-Nagel). After an extensive test phase, we established a novel magnetic bead extraction method based upon the NucleoMag™ extraction kit (Macherey-Nagel). The new method is readily automatable and produces high yields of DNA from different sample types (blood, saliva, sperm, contact stains) on various substrates (filter paper, swabs, cigarette butts) with no evidence of a loss of magnetic beads or sample cross-contamination. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Automatic delineation of brain regions on MRI and PET images from the pig.

    PubMed

    Villadsen, Jonas; Hansen, Hanne D; Jørgensen, Louise M; Keller, Sune H; Andersen, Flemming L; Petersen, Ida N; Knudsen, Gitte M; Svarer, Claus

    2018-01-15

    The increasing use of the pig as a research model in neuroimaging requires standardized processing tools. For example, extraction of regional dynamic time series from brain PET images requires parcellation procedures that benefit from being automated. Manual inter-modality spatial normalization to a MRI atlas is operator-dependent, time-consuming, and can be inaccurate with lack of cortical radiotracer binding or skull uptake. A parcellated PET template that allows for automatic spatial normalization to PET images of any radiotracer. MRI and [ 11 C]Cimbi-36 PET scans obtained in sixteen pigs made the basis for the atlas. The high resolution MRI scans allowed for creation of an accurately averaged MRI template. By aligning the within-subject PET scans to their MRI counterparts, an averaged PET template was created in the same space. We developed an automatic procedure for spatial normalization of the averaged PET template to new PET images and hereby facilitated transfer of the atlas regional parcellation. Evaluation of the automatic spatial normalization procedure found the median voxel displacement to be 0.22±0.08mm using the MRI template with individual MRI images and 0.92±0.26mm using the PET template with individual [ 11 C]Cimbi-36 PET images. We tested the automatic procedure by assessing eleven PET radiotracers with different kinetics and spatial distributions by using perfusion-weighted images of early PET time frames. We here present an automatic procedure for accurate and reproducible spatial normalization and parcellation of pig PET images of any radiotracer with reasonable blood-brain barrier penetration. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Cognitive-Affective Dimensions of Female Orgasm: The Role of Automatic Thoughts and Affect During Sexual Activity.

    PubMed

    Tavares, Inês M; Laan, Ellen T M; Nobre, Pedro J

    2017-06-01

    Cognitive-affective factors contribute to female sexual dysfunctions, defined as clinically significant difficulties in the ability to respond sexually or to experience sexual pleasure. Automatic thoughts and affect presented during sexual activity are acknowledged as maintenance factors for these difficulties. However, there is a lack of studies on the influence of these cognitive-affective dimensions regarding female orgasm. To assess the role of automatic thoughts and affect during sexual activity in predicting female orgasm occurrence and to investigate the mediator role of these variables in the relation between sexual activity and orgasm occurrence. Nine hundred twenty-six sexually active heterosexual premenopausal women reported on frequency of sexual activities and frequency of orgasm occurrence, cognitive factors, and social desirability. Participants completed the Sexual Modes Questionnaire-Automatic Thoughts Subscale, the Positive and Negative Affect Schedule, and the Socially Desirable Response Set. Multiple linear regressions and mediation analyses were performed, controlling for the effect of covariates such as social desirability, sociodemographic and medical characteristics, and relationship factors. The main outcome measurement was orgasm frequency as predicted and mediated by automatic thoughts and affect experienced during sexual activities. The presence of failure thoughts and lack of erotic thoughts during sexual activity significantly and negatively predicted female orgasm, whereas positive affect experienced during sexual activity significantly and positively predicted female orgasm. Moreover, negative automatic thoughts and positive affect during sexual activity were found to mediate the relation between sexual activity and female orgasm occurrence. These data suggest that the cognitive aspects of sexual involvement are critical to enhancing female orgasm experience and can aid the development of strategies that contemplate the central role of automatic thoughts and of positive emotions experienced during sexual activity. Data were not collected face to face, which constitutes a strength of this study, because it is known that social desirability is lower in self-administered online questionnaires compared with traditional paper-and-pencil questionnaires, particularly for more sensitive sexual issues. The fact that the sample was composed of heterosexual, premenopausal, and relatively young women demands some caution regarding generalization of the present results. The findings support the contribution of cognitive and affective factors to female orgasmic functioning. It is recommended that future research confirm these findings with other samples, particularly clinical samples of women with orgasmic difficulties. Tavares IM, Laan ETM, Nobre PJ. Cognitive-Affective Dimensions of Female Orgasm: The Role of Automatic Thoughts and Affect During Sexual Activity. J Sex Med 2017;14:818-828. Copyright © 2017 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  1. NHEXAS PHASE I MARYLAND STUDY--LIPIDS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Lipids in Blood data set presents concentrations of cholesterol and total triglycerides in blood serum. The data set presents measurements for up to 2 lipids in 358 blood samples over 79 households. Each sample was collected via a venous sample from the primary respondent w...

  2. Prevalence and risk factors of Toxoplasma gondii in fattening pigs farm from Yucatan, Mexico.

    PubMed

    Ortega-Pacheco, A; Acosta Viana, K Y; Guzmán-Marín, E; Segura-Correa, J C; Alvarez-Fleites, M; Jiménez-Coello, M

    2013-01-01

    The objective of this study was to estimate the prevalence and identify risk factors associated with the presence of Toxoplasma gondii in pig-fattening farms from Yucatan, Mexico. A cross-sectional study was conducted with a two-stage sampling. There were 429 pigs sampled from 39 farms randomly selected. Blood samples were collected to obtain DNA and serum. The presence of IgM and IgG antibodies was determined by indirect ELISA. Prevalence was estimated by diagnostic test. Potential risk factors to be included in a marginal logistic regression were tested by chi-square or Fisher. The prevalence of IgM and IgG was 92.5% (397/429) (CI 89.9-95.1%) and 95.8% (411/429) (CI 93.7-97.8%), respectively. Regarding PCR, a prevalence of 50.8% (218/429) (CI 45.9-55.6%) was found. The logistic regression showed an association with herd size and type of feeder (P < 0.05). The risk of a case in farms with ≤400 pigs was 27.9 times higher than in farms with >400 pigs. The manual feeder was a significant protective factor associated with the seropositive against T. gondii. Results indicate a high circulation of T. gondii in pig-fattening farms from Yucatan, finding an increased risk of infection for those farms with less than 400 animals and automatic feeders.

  3. A modular, open-source, slide-scanning microscope for diagnostic applications in resource-constrained settings

    PubMed Central

    Lu, Qiang; Liu, Guanghui; Xiao, Chuanli; Hu, Chuanzhen; Zhang, Shiwu; Xu, Ronald X.; Chu, Kaiqin; Xu, Qianming

    2018-01-01

    In this paper we report the development of a cost-effective, modular, open source, and fully automated slide-scanning microscope, composed entirely of easily available off-the-shelf parts, and capable of bright field and fluorescence modes. The automated X-Y stage is composed of two low-cost micrometer stages coupled to stepper motors operated in open-loop mode. The microscope is composed of a low-cost CMOS sensor and low-cost board lenses placed in a 4f configuration. The system has approximately 1 micron resolution, limited by the f/# of available board lenses. The microscope is compact, measuring just 25×25×30 cm, and has an absolute positioning accuracy of ±1 μm in the X and Y directions. A Z-stage enables autofocusing and imaging over large fields of view even on non-planar samples, and custom software enables automatic determination of sample boundaries and image mosaicking. We demonstrate the utility of our device through imaging of fluorescent- and transmission-dye stained blood and fecal smears containing human and animal parasites, as well as several prepared tissue samples. These results demonstrate image quality comparable to high-end commercial microscopes at a cost of less than US$400 for a bright-field system, with an extra US$100 needed for the fluorescence module. PMID:29543835

  4. Implementation guide for turbidity threshold sampling: principles, procedures, and analysis

    Treesearch

    Jack Lewis; Rand Eads

    2009-01-01

    Turbidity Threshold Sampling uses real-time turbidity and river stage information to automatically collect water quality samples for estimating suspended sediment loads. The system uses a programmable data logger in conjunction with a stage measurement device, a turbidity sensor, and a pumping sampler. Specialized software enables the user to control the sampling...

  5. Towards an automatic lab-on-valve-ion mobility spectrometric system for detection of cocaine abuse.

    PubMed

    Cocovi-Solberg, David J; Esteve-Turrillas, Francesc A; Armenta, Sergio; de la Guardia, Miguel; Miró, Manuel

    2017-08-25

    A lab-on-valve miniaturized system integrating on-line disposable micro-solid phase extraction has been interfaced with ion mobility spectrometry for the accurate and sensitive determination of cocaine and ecgonine methyl ester in oral fluids. The method is based on the automatic loading of 500μL of oral fluid along with the retention of target analytes and matrix clean-up by mixed-mode cationic/reversed-phase solid phase beads, followed by elution with 100μL of 2-propanol containing (3% v/v) ammonia, which are online injected into the IMS. The sorptive particles are automatically discarded after every individual assay inasmuch as the sorptive capacity of the sorbent material is proven to be dramatically deteriorated with reuse. The method provided a limit of detection of 0.3 and 0.14μgL -1 for cocaine and ecgonine methyl ester, respectively, with relative standard deviation values from 8 till 14% with a total analysis time per sample of 7.5min. Method trueness was evaluated by analyzing oral fluid samples spiked with cocaine at different concentration levels (1, 5 and 25μgL -1 ) affording relative recoveries within the range of 85±24%. Fifteen saliva samples were collected from volunteers and analysed following the proposed automatic procedure, showing a 40% cocaine occurrence with concentrations ranging from 1.3 to 97μgL -1 . Field saliva samples were also analysed by reference methods based on lateral flow immunoassay and gas chromatography-mass spectrometry. The application of this procedure to the control of oral fluids of cocaine consumers represents a step forward towards the development of a point-of-care cocaine abuse sensing system. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. [A day in Spanish microbiology. Descriptive study of the activity of the clinical microbiology departments].

    PubMed

    Prieto, J; García-Rodríguez, Ja; Barberán, J; Granizo, Jj; Rodicio, Mp; González, J

    2008-12-01

    The laboratory is an essential part of the work in the Clinical Microbiology Department. This study has aimed to measure the activity of these laboratories. A survey was self-administered on the activity occurring during one work day by each hospital in October 2007. Thirty six hospitals reported 14,076 tests. Serology was the most frequently reported test (30.3%) followed by urine culture (27.8 %), blood tests (13.2 %), respiratory tract samples (8%), feces (7.1%), urethral (5.8%), skin (5.3%) and cerebrospinal fluid (2.6%). According to species, 73.2% of the isolates were bacteria (22.9 % were positive), 8.9% were virus (17% positive), fungi 8.1% (25.2% positive), and 5.5% mycobacterias (5.9% were positive) and parasite 4.5% (12.5% positive). Susceptibility test were performed by automatic methods (62.3%) followed by diffusion test (27.1%) and E-test (9.1%). A total of 5.6% of the susceptibility tests showed in vitro resistance to antibiotics. Fungi were identified in 108 isolates. Candida and Aspergillus were the most frequent genus (85.1% and 8.3%, respectively). Origins of the samples were: lower respiratory tract (32.4 %), genital tract (24.1 %), urine (10.2 %), blood (10.2 %) and skin (10.2 %). Twelve identification techniques were used, the most frequent being the morphological test (54.8%) and biochemical test (39.7%). Broken down by departments, 20.4% were sent from the ICU, 16.7% from surgery, 29.6% from medicine and 18.5% from primary care. Although the workload of the laboratories has been measured in this work, aspects such as specimen manipulation, clinical advice and research were not considered.

  7. Evaluation of the overall efficacy of the Omron office digital blood pressure HEM-907 monitor in adults.

    PubMed

    White, W B; Anwar, Y A

    2001-04-01

    Non-invasive self blood pressure monitoring has become increasingly popular. To assure the accuracy of devices used for this purpose, all need to be validated independently prior to marketing. The objective of this study was to assess the accuracy of the HEM-907, a new semi-automatic, non-invasive, oscillometric blood pressure monitoring device specifically designed to be used in the clinic or physician's office setting. Blood pressure measurements taken employing this device were compared with the results obtained by two experienced observers using a mercury sphygmomanometer on 100 subjects and patients (384 measurements). The limits of agreement were calculated for the device compared with the results of the two observers according to the standards of the Association for the Advancement of Medical Instrumentation (AAMI). The agreement between the two observers was -0.36+/-2.32mmHg for systolic blood pressure and 0.02+/-2.42mmHg for diastolic blood pressure. The agreement between the device and the observers was 1.56+/-4.42mmHg and 3.49+/-4.61mmHg for systolic and diastolic blood pressure respectively. The Omron HEM-907 satisfied the AAMI criteria for accuracy for a non-invasive blood pressure monitoring device.

  8. LOSS OF BLOOD AT OPERATION—A Method for Continuous Measurement

    PubMed Central

    Borden, Fred W.

    1957-01-01

    A method for continuous measurement of surgical blood loss has been devised and has been used clinically in some 400 cases. The method combines volumetric measure of the suction loss and gravimetric measure of the sponge loss. The volumetric device automatically deducts the volume of rinse water used and thus measures the amount of blood collected in a metering cylinder. The suction loss scale shows continuously the amount of blood in the metering cylinder. The gravimetric device requires counting sponges into the weighing pan, and turning a dial scale to deduct the initial weight of the sponges. The volume of blood in the sponges is then read directly on the dial scale. Use of the instrument, which is under the supervision of the anesthesiologist, adds about two minutes per hour to the time normally required for counting the sponges; and about three minutes per hour is required for tending the volumetric instrument. In clinical use, knowing constantly the amount of blood loss permits the starting of transfusion before serious deficit develops, and then maintaining the patient's blood volume at a predetermined optimum level. In some 400 cases the continuous measurement of the blood loss served as a reliable guide for carrying out the loss-replacement plan within close limits of accuracy. ImagesFigure 2.p97-a PMID:13446754

  9. Study of Umbilical Cord Blood Culture in Diagnosis of Early-onset Sepsis Among Newborns with High-risk Factors.

    PubMed

    Kalathia, Mitul Babubhai; Shingala, Prakash Ashokbhai; Parmar, Parin Niranjanbhai; Parikh, Yogesh Narenedrabhai; Kalathia, Ila Mitulkumar

    2013-10-01

    Blood culture is gold standard for diagnosis of neonatal sepsis. Low sensitivity of blood culture is usually due to small volume of blood sample, intrapartum antibiotics, and antibiotics given to newborn before sampling. We evaluated use of Umbilical cord blood culture (UCBC) in diagnosis of neonatal sepsis as compared to peripheral venous blood culture. This study was done in tertiary care teaching hospital during May-June 2012. A total of 45 newborns with presence of two or more risk factors of sepsis were included. Blood sample from placental end of umbilical cord was collected and cultured. Primary outcome was diagnosis of neonatal sepsis by use of umbilical cord blood sample as compared with venous blood sample. Secondary outcome was to compare organisms identified by UCBC and venous blood culture. Sensitivity, specificity, positive and negative predictive values of UCBC were calculated. A total of 24.44% (11 out of 45) high-risk newborns had positive UCBC. A total of 17.8% (8 out of 45) newborns had positive blood culture report. Organisms grown in UCBC were Pseudomonas (45%, 5 out of 11), Acinetobacter (27.27%, 3 out of 11), Escherichia coli (18.18%, 2 out of 11), and Klebsiella (9%, 1 out of 11). UCBC is a good method for diagnosis of neonatal sepsis among high-risk newborns as compared to venous blood culture with a sensitivity of 80% and specificity of 91.43%. Organisms grown are comparable to blood culture samples.

  10. Application of Atomic Dielectric Resonance Spectroscopy for the screening of blood samples from patients with clinical variant and sporadic CJD

    PubMed Central

    Fagge, Timothy J; Barclay, G Robin; Stove, G Colin; Stove, Gordon; Robinson, Michael J; Head, Mark W; Ironside, James W; Turner, Marc L

    2007-01-01

    Background Sub-clinical variant Creutzfeldt-Jakob disease (vCJD) infection and reports of vCJD transmission through blood transfusion emphasise the need for blood screening assays to ensure the safety of blood and transplanted tissues. Most assays aim to detect abnormal prion protein (PrPSc), although achieving required sensitivity is a challenge. Methods We have used innovative Atomic Dielectric Resonance Spectroscopy (ADRS), which determines dielectric properties of materials which are established by reflectivity and penetration of radio/micro waves, to analyse blood samples from patients and controls to identify characteristic ADR signatures unique to blood from vCJD and to sCJD patients. Initial sets of blood samples from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) were screened as training samples to determine group-specific ADR characteristics, and provided a basis for classification of blinded sets of samples. Results Blood sample groups from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) screened by ADRS were classified with 100% specificity and sensitivity, discriminating these by a co-variance expert analysis system. Conclusion ADRS appears capable of recognising and discriminating serum samples from vCJD, sCJD, non-CJD neurological diseases, and normal healthy adults, and might be developed to provide a system for primary screening or confirmatory assay complementary to other screening systems. PMID:17760958

  11. Patient identification in blood sampling.

    PubMed

    Davidson, Anne; Bolton-Maggs, Paula

    The majority of adverse reports relating to blood transfusions result from human error, including misidentification of patients and incorrect labelling of samples. This article outlines best practice in blood sampling for transfusion (but is recommended for all pathology samples) and the role of patient empowerment in improving safety.

  12. Sampling and storage of blood for pH and blood gas analysis.

    PubMed

    Haskins, S C

    1977-02-15

    Techniques used in sampling and storage of a blood sample for pH and gas measurements can have an important effect on the measured values. Observation of these techniques and principles will minimize in vitro alteration of the pH and blood gas values. To consider that a significant change has occurred in a pH or blood gas measurement from previous values, the change must exceed 0.015 for pH, 3 mm Hg for PCO2, 5 mm Hg for PO2, and 2 mEq/L for [HCO-3] or base excess/deficit. In vitro dilution of the blood sample with anticoagulant should be avoided because it will alter the measured PCO2 and base excess/deficit values. Arterial samples should be collected for meaningful pH and blood gas values. Central venous and free-flowing capillary blood can be used for screening procedures in normal patients but are subject to considerable error. A blood sample can be stored for up to 30 minutes at room temperature without significant change in acid-base values but only up to 12 minutes before significant changes occur in PO2. A blood sample can be stored for up to 3.5 hours in an ice-water bath without significant change in pH and for 6 hours without significant change in PCO2 or PO2. Variations of body temperatures from normal will cause a measurable change in pH and blood gas values when the blood is exposed to the normal water bath temperatures of the analyzer.

  13. Rainfall, Discharge, and Water-Quality Data During Stormwater Monitoring, July 1, 2008, to June 30, 2009 - Halawa Stream Drainage Basin and the H-1 Storm Drain, Oahu, Hawaii

    USGS Publications Warehouse

    Presley, Todd K.; Jamison, Marcael T.J.

    2009-01-01

    Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. The program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream, and to assess the effects from the H-1 storm drain on Manoa Stream. For this program, rainfall data were collected at three stations, continuous discharge data at five stations, and water-quality data at six stations, which include the five continuous discharge stations. This report summarizes rainfall, discharge, and water-quality data collected between July 1, 2008, and June 30, 2009. Within the Halawa Stream drainage area, three storms (October 25 and December 11, 2008, and February 3, 2009) were sampled during July 1, 2008, to June 30, 2009. A total of 43 environmental samples were collected during these three storms. During the storm of October 25, 2009, 31 samples were collected and analyzed individually for metals only. The other 12 samples from the other two storms were analyzed for some or all of the following analytes: total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, and zinc). Additionally, grab samples were analyzed for some or all of the following analytes: oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Some grab and composite samples were analyzed for only a partial list of these analytes, either because samples could not be delivered to the laboratory in a timely manner, or an insufficient volume of sample was collected by the automatic samplers. Two quality-assurance/quality-control samples were collected after cleaning automatic sampler lines to verify that the sampling lines were not contaminated. Four environmental samples were collected at the H-1 Storm Drain during July 1, 2008, to June 30, 2009. An oil and grease sample and a composite sample were collected during the storm on November 15, 2008, and two composite samples were collected during the January 11, 2009, storm. All samples at this site were collected using an automatic sampler. Samples were analyzed for some or all of the following analytes: total suspended solids, nutrients, oil and grease, total petroleum hydrocarbons, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). One qualityassurance/quality-control sample was collected after cleaning automatic sampler lines to verify that the sampling lines were not contaminated. During the storm of January 11, 2009, the two composite samples collected at H-1 Storm Drain were collected about three hours apart. Higher constituent concentrations were detected in the first 2 composite sample relative to the second composite sample, although the average discharge was higher during the period when the second sample was collected.

  14. Method of high-precision microsampled blood and plasma mass densitometry

    NASA Technical Reports Server (NTRS)

    Hinghofer-Szalkay, H.

    1986-01-01

    The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.

  15. Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model

    PubMed Central

    2012-01-01

    Background Ultrasonic scalpel (UC) and monopolar electrocautery (ME) are common tools for soft tissue dissection. However, morphological data on the related tissue alteration are discordant. We developed an automatic device for standardized sample excision and compared quality and depth of morphological changes caused by UC and ME in a pig model. Methods 100 tissue samples (5 × 3 cm) of the abdominal wall were excised in 16 pigs. Excisions were randomly performed manually or by using the self-constructed automatic device at standard power levels (60 W cutting in ME, level 5 in UC) for abdominal surgery. Quality of tissue alteration and depth of coagulation necrosis were examined histopathologically. Device (UC vs. ME) and mode (manually vs. automatic) effects were studied by two-way analysis of variance at a significance level of 5%. Results At the investigated power level settings UC and ME induced qualitatively similar coagulation necroses. Mean depth of necrosis was 450.4 ± 457.8 μm for manual UC and 553.5 ± 326.9 μm for automatic UC versus 149.0 ± 74.3 μm for manual ME and 257.6 ± 119.4 μm for automatic ME. Coagulation necrosis was significantly deeper (p < 0.01) when UC was used compared to ME. The mode of excision (manual versus automatic) did not influence the depth of necrosis (p = 0.85). There was no significant interaction between dissection tool and mode of excision (p = 0.93). Conclusions Thermal injury caused by UC and ME results in qualitatively similar coagulation necrosis. The depth of necrosis is significantly greater in UC compared to ME at investigated standard power levels. PMID:22361346

  16. Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model.

    PubMed

    Homayounfar, Kia; Meis, Johanna; Jung, Klaus; Klosterhalfen, Bernd; Sprenger, Thilo; Conradi, Lena-Christin; Langer, Claus; Becker, Heinz

    2012-02-23

    Ultrasonic scalpel (UC) and monopolar electrocautery (ME) are common tools for soft tissue dissection. However, morphological data on the related tissue alteration are discordant. We developed an automatic device for standardized sample excision and compared quality and depth of morphological changes caused by UC and ME in a pig model. 100 tissue samples (5 × 3 cm) of the abdominal wall were excised in 16 pigs. Excisions were randomly performed manually or by using the self-constructed automatic device at standard power levels (60 W cutting in ME, level 5 in UC) for abdominal surgery. Quality of tissue alteration and depth of coagulation necrosis were examined histopathologically. Device (UC vs. ME) and mode (manually vs. automatic) effects were studied by two-way analysis of variance at a significance level of 5%. At the investigated power level settings UC and ME induced qualitatively similar coagulation necroses. Mean depth of necrosis was 450.4 ± 457.8 μm for manual UC and 553.5 ± 326.9 μm for automatic UC versus 149.0 ± 74.3 μm for manual ME and 257.6 ± 119.4 μm for automatic ME. Coagulation necrosis was significantly deeper (p < 0.01) when UC was used compared to ME. The mode of excision (manual versus automatic) did not influence the depth of necrosis (p = 0.85). There was no significant interaction between dissection tool and mode of excision (p = 0.93). Thermal injury caused by UC and ME results in qualitatively similar coagulation necrosis. The depth of necrosis is significantly greater in UC compared to ME at investigated standard power levels.

  17. Quality of life and glycemic profile of type 2 diabetes mellitus patients of Indonesian: a descriptive study

    NASA Astrophysics Data System (ADS)

    Amelia, R.; Lelo, A.; Lindarto, D.; Mutiara, E.

    2018-03-01

    The prevalence of diabetes type 2 is increasing globally. Quality of life (QOL) in diabetic patients is the primary goal of care. Today, there is an increasing awareness suggesting that patient’sQOLand treatment satisfaction were improved after good glycemic control. This study aimed to demonstrate the quality of life and the glycemic profiles of type 2 Diabetes Mellitus patients. This study was a descriptive study of across-sectional design. A sample of 115 out-patients attending eight public health centers in Binjai City, Indonesia. Patient’s quality of life was assessedin four domains of role limitation due to physical health, psychosocial, social and environment in a four Likert point. Two glycemic profiles which are blood sugar level and glycated hemoglobin (HbA1c) were measured by Spectrophotometer Colorimeter + Full Automatic method and affinity Doronad + Modified HPLC technique, respectively. In the results, we confirmed that almost 80.0% of diabetes mellitus type 2 patients are in good QOL(score 81-100) in three QOL dimensions; Physical health, Social relationship and Environment health but not in Psychological health dimension. The blood sugar level and HbA1clevel are beyond the normal value, 267.5±103.2mg/dLand9.9±2.3%,respectively. The better controlled glycemic index, the better patient’s QOL.

  18. [Implementation of a community tele-epidemiological surveillance system using information and communication technologies in Paraguay].

    PubMed

    Galván, Pedro; Cane, Virgilio; Samudio, Margarita; Cabello, Agueda; Cabral, Margarita; Basogain, Xavier; Rivas, Ronald; Hilario, Enrique

    2014-01-01

    Report preliminary results of the application of the BONIS system in community tele-epidemiological surveillance in Paraguay. A study of viability and implementation carried out in the Family Health Unit located in Bañado Sur in the city of Asunción by the Paraguay River. The system automatically records personal data and symptoms of individuals who make telephone reports, and suspected cases of dengue are classified and prioritized. This information goes to community agents for follow-up and to specialists in charge of epidemiological surveillance. From April 2010 to August 2011, 1 028 calls to the system were logged. Of 157 reported cases of fever, home visits were made to 140 (89.2%); of these, fever and headache or body ache were confirmed in 52 (37.1%) cases, and headache or body ache without fever in 58 (41.4%) cases. Community agents referred 49 (35.0%) of them for medical consultation and blood tests, and they took blood samples in the homes of 19; of these, 56 (82.3%) were positive for dengue and 12 (17.4%) for influenza. Paraguay has a low-cost community tele-epidemiological surveillance system based on information and communication technologies and open-source software, which is scalable to other health symptoms and disorders of interest. To enable its acceptance and application, education programs should be developed to strengthen the management and promotion of community health.

  19. A technique for extracting blood samples from mice in fire toxicity tests

    NASA Technical Reports Server (NTRS)

    Bucci, T. J.; Hilado, C. J.; Lopez, M. T.

    1976-01-01

    The extraction of adequate blood samples from moribund and dead mice has been a problem because of the small quantity of blood in each animal and the short time available between the animals' death and coagulation of the blood. These difficulties are particularly critical in fire toxicity tests because removal of the test animals while observing proper safety precautions for personnel is time-consuming. Techniques for extracting blood samples from mice were evaluated, and a technique was developed to obtain up to 0.8 ml of blood from a single mouse after death. The technique involves rapid exposure and cutting of the posterior vena cava and accumulation of blood in the peritoneal space. Blood samples of 0.5 ml or more from individual mice have been consistently obtained as much as 16 minutes after apparent death. Results of carboxyhemoglobin analyses of blood appeared reproducible and consistent with carbon monoxide concentrations in the exposure chamber.

  20. Cost Analysis of Various Low Pathogenic Avian Influenza Surveillance Systems in the Dutch Egg Layer Sector

    PubMed Central

    Rutten, Niels; Gonzales, José L.; Elbers, Armin R. W.; Velthuis, Annet G. J.

    2012-01-01

    Background As low pathogenic avian influenza viruses can mutate into high pathogenic viruses the Dutch poultry sector implemented a surveillance system for low pathogenic avian influenza (LPAI) based on blood samples. It has been suggested that egg yolk samples could be sampled instead of blood samples to survey egg layer farms. To support future decision making about AI surveillance economic criteria are important. Therefore a cost analysis is performed on systems that use either blood or eggs as sampled material. Methodology/Principal Findings The effectiveness of surveillance using egg or blood samples was evaluated using scenario tree models. Then an economic model was developed that calculates the total costs for eight surveillance systems that have equal effectiveness. The model considers costs for sampling, sample preparation, sample transport, testing, communication of test results and for the confirmation test on false positive results. The surveillance systems varied in sampled material (eggs or blood), sampling location (farm or packing station) and location of sample preparation (laboratory or packing station). It is shown that a hypothetical system in which eggs are sampled at the packing station and samples prepared in a laboratory had the lowest total costs (i.e. € 273,393) a year. Compared to this a hypothetical system in which eggs are sampled at the farm and samples prepared at a laboratory, and the currently implemented system in which blood is sampled at the farm and samples prepared at a laboratory have 6% and 39% higher costs respectively. Conclusions/Significance This study shows that surveillance for avian influenza on egg yolk samples can be done at lower costs than surveillance based on blood samples. The model can be used in future comparison of surveillance systems for different pathogens and hazards. PMID:22523543

  1. NHEXAS PHASE I MARYLAND STUDY--PESTICIDES IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticides in Blood Serum data set contains analytical results for measurements of up to 17 pesticides in 358 blood samples over 79 households. Each sample was collected via a venous sample from the primary respondent within each household by a phlebotomist. Samples were ge...

  2. Development of a new control device for stabilizing blood level in reservoir during extracorporeal circulation.

    PubMed

    Momose, Naoki; Yamakoshi, Rie; Kokubo, Ryo; Yasuda, Toru; Iwamoto, Norio; Umeda, Chinori; Nakajima, Itsuro; Yanagisawa, Mitsunobu; Tomizawa, Yasuko

    2010-03-01

    We developed a simple device that stabilizes the blood level in the reservoir of the extracorporeal circulation open circuit system by measuring the hydrostatic pressure of the reservoir to control the flow rate of the arterial pump. When the flow rate of the venous return decreases, the rotation speed of the arterial pump is automatically slowed down. Consequently, the blood level in the reservoir is stabilized quickly between two arbitrarily set levels and never falls below the pre-set low level. We conducted a basic experiment to verify the operation of the device, using a mock circuit with water. Commercially available pumps and reservoir were used without modification. The results confirmed that the control method effectively regulates the reservoir liquid level and is highly reliable. The device possibly also functions as a safety device.

  3. Automated segmentation of retinal blood vessels and identification of proliferative diabetic retinopathy

    NASA Astrophysics Data System (ADS)

    Jelinek, Herbert F.; Cree, Michael J.; Leandro, Jorge J. G.; Soares, João V. B.; Cesar, Roberto M.; Luckie, A.

    2007-05-01

    Proliferative diabetic retinopathy can lead to blindness. However, early recognition allows appropriate, timely intervention. Fluorescein-labeled retinal blood vessels of 27 digital images were automatically segmented using the Gabor wavelet transform and classified using traditional features such as area, perimeter, and an additional five morphological features based on the derivatives-of-Gaussian wavelet-derived data. Discriminant analysis indicated that traditional features do not detect early proliferative retinopathy. The best single feature for discrimination was the wavelet curvature with an area under the curve (AUC) of 0.76. Linear discriminant analysis with a selection of six features achieved an AUC of 0.90 (0.73-0.97, 95% confidence interval). The wavelet method was able to segment retinal blood vessels and classify the images according to the presence or absence of proliferative retinopathy.

  4. Cross-spectral coherence between geomagnetic disturbance and human cardiovascular variables at non-societal frequencies.

    PubMed

    Watanabe, Y; Hillman, D C; Otsuka, K; Bingham, C; Breus, T K; Cornélissen, G; Halberg, F

    1994-01-01

    A 35-year-old cardiologist monitored himself with an automatic ABPM-630 (Colin Electronics) monitor, mostly at 15-minute intervals around-the-clock for three years with a few interruptions. In this subject with a family history of high blood pressure and stroke, a cross-spectral analysis revealed a statistically significant coherence at 27.7 days between systolic and diastolic blood pressure and heart rate vs. the geomagnetic disturbance index, Kp. A lesser peak in coherence was found for systolic blood pressure with Kp at a trial period of 4.16 days (P = 0.046). These results suggest that changes in geomagnetism may influence the human circulation, at least in the presence of familial cardiovascular disease risk, and they may do so at frequencies that have no precise human-made cyclic worldwide match.

  5. Engineering an in vitro air-blood barrier by 3D bioprinting

    PubMed Central

    Horváth, Lenke; Umehara, Yuki; Jud, Corinne; Blank, Fabian; Petri-Fink, Alke; Rothen-Rutishauser, Barbara

    2015-01-01

    Intensive efforts in recent years to develop and commercialize in vitro alternatives in the field of risk assessment have yielded new promising two- and three dimensional (3D) cell culture models. Nevertheless, a realistic 3D in vitro alveolar model is not available yet. Here we report on the biofabrication of the human air-blood tissue barrier analogue composed of an endothelial cell, basement membrane and epithelial cell layer by using a bioprinting technology. In contrary to the manual method, we demonstrate that this technique enables automatized and reproducible creation of thinner and more homogeneous cell layers, which is required for an optimal air-blood tissue barrier. This bioprinting platform will offer an excellent tool to engineer an advanced 3D lung model for high-throughput screening for safety assessment and drug efficacy testing. PMID:25609567

  6. Capillary blood sampling: national recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana; Maradin, Miljenka

    2015-01-01

    Capillary blood sampling is a medical procedure aimed at assisting in patient diagnosis, management and treatment, and is increasingly used worldwide, in part because of the increasing availability of point-of-care testing. It is also frequently used to obtain small blood volumes for laboratory testing because it minimizes pain. The capillary blood sampling procedure can influence the quality of the sample as well as the accuracy of test results, highlighting the need for immediate, widespread standardization. A recent nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia has shown that capillary sampling procedures are not standardized and that only a small proportion of Croatian laboratories comply with guidelines from the Clinical Laboratory Standards Institute (CLSI) or the World Health Organization (WHO). The aim of this document is to provide recommendations for capillary blood sampling. This document has been produced by the Working Group for Capillary Blood Sampling within the Croatian Society of Medical Biochemistry and Laboratory Medicine. Our recommendations are based on existing available standards and recommendations (WHO Best Practices in Phlebotomy, CLSI GP42-A6 and CLSI C46-A2), which have been modified based on local logistical, cultural, legal and regulatory requirements. We hope that these recommendations will be a useful contribution to the standardization of capillary blood sampling in Croatia. PMID:26524965

  7. Capillary blood sampling: national recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana; Maradin, Miljenka

    2015-01-01

    Capillary blood sampling is a medical procedure aimed at assisting in patient diagnosis, management and treatment, and is increasingly used worldwide, in part because of the increasing availability of point-of-care testing. It is also frequently used to obtain small blood volumes for laboratory testing because it minimizes pain. The capillary blood sampling procedure can influence the quality of the sample as well as the accuracy of test results, highlighting the need for immediate, widespread standardization. A recent nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia has shown that capillary sampling procedures are not standardized and that only a small proportion of Croatian laboratories comply with guidelines from the Clinical Laboratory Standards Institute (CLSI) or the World Health Organization (WHO). The aim of this document is to provide recommendations for capillary blood sampling. This document has been produced by the Working Group for Capillary Blood Sampling within the Croatian Society of Medical Biochemistry and Laboratory Medicine. Our recommendations are based on existing available standards and recommendations (WHO Best Practices in Phlebotomy, CLSI GP42-A6 and CLSI C46-A2), which have been modified based on local logistical, cultural, legal and regulatory requirements. We hope that these recommendations will be a useful contribution to the standardization of capillary blood sampling in Croatia.

  8. Detection of antileishmanial antibodies in blood sampled from blood bank donors in Istanbul.

    PubMed

    Ates, Sezen Canim; Bagirova, Malahat; Allahverdiyev, Adil M; Baydar, Serap Yesilkir; Koc, Rabia Cakir; Elcicek, Serhat; Abamor, Emrah Sefik; Oztel, Olga Nehir

    2012-06-01

    According to the WHO, only 5-20% of the total cases of leishmaniasis are symptomatic leishmaniasis; the other cases are identified as asymptomatic leishmaniasis. In recent studies, it has been demonstrated that donor blood plays an important role in the epidemiology of asymptomatic leishmaniasis. However, the number of the studies on this subject is still insufficient. Additionally, donor blood samples obtained from Istanbul, which is the biggest metropolitan area in Turkey, have not been investigated with regard to Leishmania. Moreover, there is no information about the sensitivity of noninvasive serological methods that are used in the detection of leishmaniasis donor blood samples. Accordingly, this study aimed to investigate the presence of antileishmanial antibodies in blood samples obtained from blood bank donors in Istanbul, by using different serologic methods, and to determine the most sensitive detection method. Blood samples were taken from 188 healthy blood bank donors to the Capa Turkish Red Crescent Blood Bank (Istanbul, Turkey), and the presence of antileishmanial antibodies was measured by indirect immunofluorescent antibody test (IFAT), ELISA, immunochromatographic dipstick rapid test, and western blot (WB). Antileishmanial antibodies were determined in 12 out of 188 samples by IFAT (6.4%), and six out of these 12 donors were found to be positive at diagnostic titer 1:128 (3.2%). One hundred and eighty eight samples were investigated by ELISA and one (0.5%) of them gave a positive result. None of 188 samples provided a positive result by immunochromatographic test. WB applied to the 12 seroreactive donors showed that three out of 12 donors were positive. In this study, the presence of antileishmanial antibodies in blood samples of blood bank donors from Istanbul has been demonstrated by using feasible and low-cost serological methods. Additionally, in comparison with other simple and low-cost detection methods, WB was used for confirmation. IFAT has a higher sensitivity and therefore may be preferred as a prescreening method in endemic or nonendemic areas.

  9. Growth hormone suppression test

    MedlinePlus

    GH suppression test; Glucose loading test; Acromegaly - blood test; Gigantism - blood test ... At least 3 blood samples are taken. The test is done in the following way: The first blood sample is collected between 6 ...

  10. [Participation of leucocytes in pathogenesis of primary forms of lower limb chronic venous disease].

    PubMed

    Bogachev, V Iu; Golovanova, O V; Sergeeva, N A; Kuznetsov, A N

    2011-01-01

    The purpose of the study was to test the hypothesis on participation of WBCs in damaging the venous wall in patients presenting with primary forms of lower limb chronic venous diseases LLCVD . The study included a total of fifteen consecutively selected patients (13 women and 2 men) diagnosed as having grade C2-C-4 LLCVD according to the CEAP classification. Static loading (30 minutes in the sitting position) was followed by simultaneous sampling of blood from the varicose vein of the cms and ulnar vein. The total blood count including determination of both the absolute values and percentage of blood formed elements was performed using the automated haematological counter «Advia 7» («Bayer», USA). The obtained findings were statistically processed using the Microsoft Office Excel software by means of the pared two-sample τ-test for the average values. The number of leukocytes and their subpopulations in blood samples obtained from the crural varicose veins turned out to be significantly less as compared with that in blood sampled from the ulnar vein. Thus, blood sampled from the crural varicose veins demonstrated a decrease in the counts of WBC by 9.6% in fourteen (93.3%) patients, that of neutrophils by 4.9% in twelve (80%) patients, that of lymphocytes by 16,8% in fifteen (100%) patients, and that oi monocytes by 24% in twelve (80%) patients. The mentioned differences were statistically significant at a = 0.05. The eosinophilic counts in blood sampled from the upper and lower extremities appeared similar in 66.7% of the examined subjects. In 33.3% of cases the eosinophilic count in blood samples from crural varicose vein was by 16.7% lower than that for blood samples form the ulnar vein. No differences for the rest parameters of the clinical blood count were revealed. The absolute lymphocytic count in the blood samples taken after the 30-minute static loading from the crural varicose veins was significantly lower as compared with that in blood sampled form the cubital vein. The counts for RBCs and blood platelets, as well as other qualitative haematological indices (haemoglobin, haematocrit, average volume of the RBC, erythrocytic diameter, etc.) in blood sampled form crural and ulnar veins in the same patient were identical, thus strongly suggesting the lack of either haemodynamic or haemorheological phenomena capable of leading to redistribution of the blood formed elements in varicose veins. Hence a decrease in the counts of leukocytes and their subpopulations in blood sampled from crural varicose veins might be associated with the «leukocytic trap» phenomenon.

  11. [Impact of current approaches to laboratory screening of donated blood and its components on hepatitis B virus infection in patients with blood system diseases].

    PubMed

    Ignatova, E N; Tupoleva, T A; Ovchinnikova, E N; Romanova, T Yu; Yaroslavtseva, N G; Filatov, F P; Troitskaya, V V; Kuzmina, L A; Parovichnikova, E N; Gaponova, T V; Savchenko, V G

    To evaluate the detection rate of markers for hepatitis B virus (HBV) in the blood samples taken from patients with blood system diseases, by applying the current approaches to examining donated blood and its components for markers of viral infections. The investigation included blood samples from patients with blood system diseases (n=364) and donors (n=5,011). The results of laboratory screening of donated blood samples (n=13,081) were retrospectively analyzed. Commercial kits of reagents were used for immunochemical assay and polymerase chain reaction. Patients with blood system diseases were recorded to have markers of active HBV infection in 12.6% of cases, anti-HBc in 31.3%, and anti-HBs in 37.6%. A retrospective analysis of the results of screening donated blood samples showed the presence of markers for active HBV infection in 0.28% of cases. A prospective examination of blood donors revealed markers of HBV infection in 4.83% of cases, including those of active forms in 0.54% and anti-HBc in 4.79%. The markers of active HBV infection in donors were only anti-HBc IgM in 0.42% of cases. The blood samples from donors with an anti-HBs titer of >200 mIU/ml contained anti-HBc IgM in 10.5%. In the last 5-7 years, the detection rate of markers of HBV infection in the blood samples of patients with blood system diseases have remained at a high level. Screening for decreed markers fails to identify people with inapparent infections among the donors. Even high anti-HBs concentrations in the donated blood may be a risk for HBV transmission by transfusion to a recipient.

  12. The 24-hour pulse wave velocity, aortic augmentation index, and central blood pressure in normotensive volunteers

    PubMed Central

    Kuznetsova, Tatyana Y; Korneva, Viktoria A; Bryantseva, Evgeniya N; Barkan, Vitaliy S; Orlov, Artemy V; Posokhov, Igor N; Rogoza, Anatoly N

    2014-01-01

    The purpose of this study was to examine the pulse wave velocity, aortic augmentation index corrected for heart rate 75 (AIx@75), and central systolic and diastolic blood pressure during 24-hour monitoring in normotensive volunteers. Overall, 467 subjects (206 men and 261 women) were recruited in this study. Participants were excluded from the study if they were less than 19 years of age, had blood test abnormalities, had a body mass index greater than 2 7.5 kg/m2, had impaired glucose tolerance, or had hypotension or hypertension. Ambulatory blood pressure monitoring (ABPM) with the BPLab® device was performed in each subject. ABPM waveforms were analyzed using the special automatic Vasotens® algorithm, which allows the calculation of pulse wave velocity, AIx@75, central systolic and diastolic blood pressure for “24-hour”, “awake”, and “asleep” periods. Circadian rhythms and sex differences in these indexes were identified. Pending further validation in prospective outcome-based studies, our data may be used as preliminary diagnostic values for the BPLab ABPM additional index in adult subjects. PMID:24812515

  13. A Complete System for Automatic Extraction of Left Ventricular Myocardium From CT Images Using Shape Segmentation and Contour Evolution

    PubMed Central

    Zhu, Liangjia; Gao, Yi; Appia, Vikram; Yezzi, Anthony; Arepalli, Chesnal; Faber, Tracy; Stillman, Arthur; Tannenbaum, Allen

    2014-01-01

    The left ventricular myocardium plays a key role in the entire circulation system and an automatic delineation of the myocardium is a prerequisite for most of the subsequent functional analysis. In this paper, we present a complete system for an automatic segmentation of the left ventricular myocardium from cardiac computed tomography (CT) images using the shape information from images to be segmented. The system follows a coarse-to-fine strategy by first localizing the left ventricle and then deforming the myocardial surfaces of the left ventricle to refine the segmentation. In particular, the blood pool of a CT image is extracted and represented as a triangulated surface. Then, the left ventricle is localized as a salient component on this surface using geometric and anatomical characteristics. After that, the myocardial surfaces are initialized from the localization result and evolved by applying forces from the image intensities with a constraint based on the initial myocardial surface locations. The proposed framework has been validated on 34-human and 12-pig CT images, and the robustness and accuracy are demonstrated. PMID:24723531

  14. Automatic coronary artery segmentation based on multi-domains remapping and quantile regression in angiographies.

    PubMed

    Li, Zhixun; Zhang, Yingtao; Gong, Huiling; Li, Weimin; Tang, Xianglong

    2016-12-01

    Coronary artery disease has become the most dangerous diseases to human life. And coronary artery segmentation is the basis of computer aided diagnosis and analysis. Existing segmentation methods are difficult to handle the complex vascular texture due to the projective nature in conventional coronary angiography. Due to large amount of data and complex vascular shapes, any manual annotation has become increasingly unrealistic. A fully automatic segmentation method is necessary in clinic practice. In this work, we study a method based on reliable boundaries via multi-domains remapping and robust discrepancy correction via distance balance and quantile regression for automatic coronary artery segmentation of angiography images. The proposed method can not only segment overlapping vascular structures robustly, but also achieve good performance in low contrast regions. The effectiveness of our approach is demonstrated on a variety of coronary blood vessels compared with the existing methods. The overall segmentation performances si, fnvf, fvpf and tpvf were 95.135%, 3.733%, 6.113%, 96.268%, respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. A simple bubble-flowmeter with quasicontinuous registration.

    PubMed

    Ludt, H; Herrmann, H D

    1976-07-22

    The construction of a simple bubble-flow-meter is described. The instrument has the following features: 1. automatic bubble injection, 2. precise measurement of the bubble passage time by a digital counter, 3. quasicontinuous registration of the flow rate, 4. alternative run with clear fluid (water) and coloured fluid (blood), 5. low volume, 6. closed measuring system for measurements in low and high pressure systems.

  16. NHEXAS PHASE I ARIZONA STUDY--METALS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 165 blood samples over 165 households. Each sample was collected as a venous sample from the primary respondent within each household during Stage III of the NHEXAS study. The samples...

  17. NHEXAS PHASE I MARYLAND STUDY--METALS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 374 blood samples over 80 households. Each sample was collected via a venous sample from the primary respondent within each household by a phlebotomist. Samples were generally drawn o...

  18. Bedside arterial blood gas monitoring system using fluorescent optical sensors

    NASA Astrophysics Data System (ADS)

    Bartnik, Daniel J.; Rymut, Russell A.

    1995-05-01

    We describe a bedside arterial blood gas (ABG) monitoring system which uses fluorescent optical sensors in the measurement of blood pH, PCO2 and PO2. The Point-of-Care Arterial Blood Gas Monitoring System consists of the SensiCathTM optical sensor unit manufactured by Optical Sensors Incorporated and the TramTM Critical Care Monitoring System with ABG Module manufactured by Marquette Electronics Incorporated. Current blood gas measurement techniques require a blood sample to be removed from the patient and transported to an electrochemical analyzer for analysis. The ABG system does not require removal of blood from the patient or transport of the sample. The sensor is added to the patient's existing arterial line. ABG measurements are made by drawing a small blood sample from the arterial line in sufficient quantity to ensure an undiluted sample at the sensor. Measurements of pH, PCO2 and PO2 are made within 60 seconds. The blood is then returned to the patient, the line flushed and results appear on the bedside monitor. The ABG system offers several advantages over traditional electrochemical analyzers. Since the arterial line remains closed during the blood sampling procedure the patient's risk of infection is reduced and the caregiver's exposure to blood is eliminated. The single-use, disposable sensor can be measure 100 blood samples over 72 hours after a single two-point calibration. Quality Assurance checks are also available and provide the caregiver the ability to assess system performance even after the sensor is patient attached. The ABG module integrates with an existing bedside monitoring system. This allows ABG results to appear on the same display as ECG, respiration, blood pressure, cardiac output, SpO2, and other clinical information. The small module takes up little space in the crowded intensive care unit. Performance studies compare the ABG system with an electrochemical blood gas analyzer. Study results demonstrated accurate and precise blood gas measurement of 100 samples and 72 hour performance without need for re-calibration.

  19. 90-kilobar diamond-anvil high-pressure cell for use on an automatic diffractometer.

    PubMed

    Schiferl, D; Jamieson, J C; Lenko, J E

    1978-03-01

    A gasketed diamond-anvil high-pressure cell is described which can be used on a four-circle automatic diffractometer to collect x-ray intensity data from single-crystal samples subjected to truly hydrostatic pressures of over 90 kilobars. The force generating system exerts only forces normal to the diamond faces to obtain maximum reliability. A unique design allows exceptionally large open areas for maximum x-ray access and is particularly well suited for highly absorbing materials, as the x rays are not transmitted through the sample. Studies on ruby show that high-pressure crystal structure determinations may be done rapidly, reliably, and routinely with this system.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uchida, Y., E-mail: h1312101@mailg.nc-toyama.ac.jp; Takada, E.; Fujisaki, A.

    Neutron and γ-ray (n-γ) discrimination with a digital signal processing system has been used to measure the neutron emission profile in magnetic confinement fusion devices. However, a sampling rate must be set low to extend the measurement time because the memory storage is limited. Time jitter decreases a discrimination quality due to a low sampling rate. As described in this paper, a new charge comparison method was developed. Furthermore, automatic n-γ discrimination method was examined using a probabilistic approach. Analysis results were investigated using the figure of merit. Results show that the discrimination quality was improved. Automatic discrimination was appliedmore » using the EM algorithm and k-means algorithm.« less

  1. Human blood RNA stabilization in samples collected and transported for a large biobank

    PubMed Central

    2012-01-01

    Background The Norwegian Mother and Child Cohort Study (MoBa) is a nation-wide population-based pregnancy cohort initiated in 1999, comprising more than 108.000 pregnancies recruited between 1999 and 2008. In this study we evaluated the feasibility of integrating RNA analyses into existing MoBa protocols. We compared two different blood RNA collection tube systems – the PAXgene™ Blood RNA system and the Tempus™ Blood RNA system - and assessed the effects of suboptimal blood volumes in collection tubes and of transportation of blood samples by standard mail. Endpoints to characterize the samples were RNA quality and yield, and the RNA transcript stability of selected genes. Findings High-quality RNA could be extracted from blood samples stabilized with both PAXgene and Tempus tubes. The RNA yields obtained from the blood samples collected in Tempus tubes were consistently higher than from PAXgene tubes. Higher RNA yields were obtained from cord blood (3 – 4 times) compared to adult blood with both types of tubes. Transportation of samples by standard mail had moderate effects on RNA quality and RNA transcript stability; the overall RNA quality of the transported samples was high. Some unexplained changes in gene expression were noted, which seemed to correlate with suboptimal blood volumes collected in the tubes. Temperature variations during transportation may also be of some importance. Conclusions Our results strongly suggest that special collection tubes are necessary for RNA stabilization and they should be used for establishing new biobanks. We also show that the 50,000 samples collected in the MoBa biobank provide RNA of high quality and in sufficient amounts to allow gene expression analyses for studying the association of disease with altered patterns of gene expression. PMID:22988904

  2. a Sensor Based Automatic Ovulation Prediction System for Dairy Cows

    NASA Astrophysics Data System (ADS)

    Mottram, Toby; Hart, John; Pemberton, Roy

    2000-12-01

    Sensor scientists have been successful in developing detectors for tiny concentrations of rare compounds, but the work is rarely applied in practice. Any but the most trivial application of sensors requires a specification that should include a sampling system, a sensor, a calibration system and a model of how the information is to be used to control the process of interest. The specification of the sensor system should ask the following questions. How will the material to be analysed be sampled? What decision can be made with the information available from a proposed sensor? This project provides a model of a systems approach to the implementation of automatic ovulation prediction in dairy cows. A healthy well managed dairy cow should calve every year to make the best use of forage. As most cows are inseminated artificially it is of vital importance mat cows are regularly monitored for signs of oestrus. The pressure on dairymen to manage more cows often leads to less time being available for observation of cows to detect oestrus. This, together with breeding and feeding for increased yields, has led to a reduction in reproductive performance. In the UK the typical dairy farmer could save € 12800 per year if ovulation could be predicted accurately. Research over a number of years has shown that regular analysis of milk samples with tests based on enzyme linked immunoassay (ELISA) can map the ovulation cycle. However, these tests require the farmer to implement a manually operated sampling and analysis procedure and the technique has not been widely taken up. The best potential method of achieving 98% specificity of prediction of ovulation is to adapt biosensor techniques to emulate the ELISA tests automatically in the milking system. An automated ovulation prediction system for dairy cows is specified. The system integrates a biosensor with automatic milk sampling and a herd management database. The biosensor is a screen printed carbon electrode system capable of measuring concentrations of progesterone in milk in the range 0.3-25 ng/ml. The system is operational in the laboratory is described here and will be working on a test farm in the near future to automatically predict the ovulation of dairy cows routinely.

  3. In vivo classification of human skin burns using machine learning and quantitative features captured by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Singla, Neeru; Srivastava, Vishal; Singh Mehta, Dalip

    2018-02-01

    We report the first fully automated detection of human skin burn injuries in vivo, with the goal of automatic surgical margin assessment based on optical coherence tomography (OCT) images. Our proposed automated procedure entails building a machine-learning-based classifier by extracting quantitative features from normal and burn tissue images recorded by OCT. In this study, 56 samples (28 normal, 28 burned) were imaged by OCT and eight features were extracted. A linear model classifier was trained using 34 samples and 22 samples were used to test the model. Sensitivity of 91.6% and specificity of 90% were obtained. Our results demonstrate the capability of a computer-aided technique for accurately and automatically identifying burn tissue resection margins during surgical treatment.

  4. Determination of pesticides in waters by automatic on-line solid-phase extraction-capillary electrophoresis.

    PubMed

    Hinsmann, P; Arce, L; Ríos, A; Valcárcel, M

    2000-01-07

    The separation of seven pesticides by micellar electrokinetic capillary chromatography in spiked water samples is described, allowing the analysis of pesticides mixtures down to a concentration of 50 microg l(-1) in less than 13 min. Calibration, pre-concentration, elution and injection into the sample vial was carried out automatically by a continuous flow system (CFS) coupled to a capillary electrophoresis system via a programmable arm. The whole system was electronically coupled by a micro-processor and completely controlled by a computer. A C18 solid-phase mini-column was used for the pre-concentration, allowing a 12-fold enrichment (as an average value) of the pesticides from fortified water samples. Under the optimal extraction conditions, recoveries between 90 and 114% for most of the pesticides were obtained.

  5. Development and testing of a portable wind sensitive directional air sampler

    NASA Technical Reports Server (NTRS)

    Deyo, J.; Toma, J.; King, R. B.

    1975-01-01

    A portable wind sensitive directional air sampler was developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. The unit, designated Air Scout, receives wind direction signals from an associated wind vane. Air samples are collected on filter slides using a standard high volume air sampler drawing air through a porting arrangement which tracks the wind direction and permits collection of discrete samples. A preset timer controls the length of time each filter is in the sampling position. At the conclusion of the sampling period a new filter is automatically moved into sampling position displacing the previous filter to a storage compartment. Thus the Air Scout may be set up at a field location, loaded with up to 12 filter slides, and left to acquire air samples automatically, according to the wind, at any timer interval desired from 1 to 30 hours.

  6. Urine sampling and collection system

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Reinhardt, C. G.

    1971-01-01

    This specification defines the performance and design requirements for the urine sampling and collection system engineering model and establishes requirements for its design, development, and test. The model shall provide conceptual verification of a system applicable to manned space flight which will automatically provide for collection, volume sensing, and sampling of urine.

  7. Umbilical Arterial Blood Sampling Alters Cerebral Tissue Oxygenation in Very Low Birth Weight Neonates.

    PubMed

    Mintzer, Jonathan P; Parvez, Boriana; La Gamma, Edmund F

    2015-11-01

    To evaluate the magnitude, consistency, and natural history of reductions in cerebral regional tissue oxygenation (CrSO2) during umbilical arterial (UA) blood sampling in very low birth weight neonates. Data were collected during a prospective observational near-infrared spectroscopy survey conducted on a convenience sample of 500-1250 g neonates during the first 10 postnatal days. A before-after analysis of UA blood sampling effects on CrSO2 absolute values and variability was performed. The present analysis was not designed a priori and was conducted following the bedside observation of CrSO2 decrements contiguous with UA blood draws. Fifteen very low birth weight neonates had 201 UA blood draws. Baseline CrSO2 (mean ± SEM) decreased following UA blood sampling, from 70 ± 1% to a nadir of 63 ± 1% (P < .001) occurring 4 ± 3 (range 2-24) minutes following blood draws. CrSO2 subsequently increased to 70 ± 1% (P < .001 compared with nadir) at 10 ± 4 (range 4-28) minutes following UA blood sampling. Coefficients of variation (mean ± SEM) increased from 0.02 ± 0.001 at baseline to 0.05 ± 0.004 (P < .001), followed by a decrease to 0.03 ± 0.003 (P < .001 for all comparisons), thus denoting increased CrSO2 variability following UA blood sampling. UA blood sampling is associated with significant CrSO2 decrements with increased variability over clinically significant intervals. Whether these changes impact complications of prematurity, including intraventricular hemorrhage and periventricular leukomalacia, remain unknown. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Automatic and strategic measures as predictors of mirror gazing among individuals with body dysmorphic disorder symptoms.

    PubMed

    Clerkin, Elise M; Teachman, Bethany A

    2009-08-01

    The current study tests cognitive-behavioral models of body dysmorphic disorder (BDD) by examining the relationship between cognitive biases and correlates of mirror gazing. To provide a more comprehensive picture, we investigated both relatively strategic (i.e., available for conscious introspection) and automatic (i.e., outside conscious control) measures of cognitive biases in a sample with either high (n = 32) or low (n = 31) BDD symptoms. Specifically, we examined the extent that (1) explicit interpretations tied to appearance, as well as (2) automatic associations and (3) strategic evaluations of the importance of attractiveness predict anxiety and avoidance associated with mirror gazing. Results indicated that interpretations tied to appearance uniquely predicted self-reported desire to avoid, whereas strategic evaluations of appearance uniquely predicted peak anxiety associated with mirror gazing, and automatic appearance associations uniquely predicted behavioral avoidance. These results offer considerable support for cognitive models of BDD, and suggest a dissociation between automatic and strategic measures.

  9. Automatic and Strategic Measures as Predictors of Mirror Gazing Among Individuals with Body Dysmorphic Disorder Symptoms

    PubMed Central

    Clerkin, Elise M.; Teachman, Bethany A.

    2011-01-01

    The current study tests cognitive-behavioral models of body dysmorphic disorder (BDD) by examining the relationship between cognitive biases and correlates of mirror gazing. To provide a more comprehensive picture, we investigated both relatively strategic (i.e., available for conscious introspection) and automatic (i.e., outside conscious control) measures of cognitive biases in a sample with either high (n=32) or low (n=31) BDD symptoms. Specifically, we examined the extent that 1) explicit interpretations tied to appearance, as well as 2) automatic associations and 3) strategic evaluations of the importance of attractiveness predict anxiety and avoidance associated with mirror gazing. Results indicated that interpretations tied to appearance uniquely predicted self-reported desire to avoid, while strategic evaluations of appearance uniquely predicted peak anxiety associated with mirror gazing, and automatic appearance associations uniquely predicted behavioral avoidance. These results offer considerable support for cognitive models of BDD, and suggest a dissociation between automatic and strategic measures. PMID:19684496

  10. Opportunistic screening of atrial fibrillation by automatic blood pressure measurement in the community.

    PubMed

    Omboni, Stefano; Verberk, Willem J

    2016-04-12

    Timely detection of atrial fibrillation (AF) may effectively prevent cardiovascular consequences. However, traditional diagnostic tools are either poorly reliable (pulse palpation) or not readily accessible (ECG) in general practice. We tested whether an automatic oscillometric blood pressure (BP) monitor embedded with an algorithm for AF detection might be effective for opportunistic screening of asymptomatic AF in the community. A community-based screening campaign in an unselected population to verify the feasibility of AF screening with a Microlife WatchBP Office BP monitor with a patented AFIB algorithm. When possible AF was detected (≥2 of 3 BP measurements reporting AF), a doctor immediately performed a single-lead ECG in order to confirm or exclude the presence of the arrhythmia. The main demographic and clinical data were also collected. 220 consecutive participants from an unselected sample of individuals in a small Italian community. Number of patients detected with AF and diagnosed risk factors for AF. In 12 of 220 participants, the device detected possible AF during the BP measurement: in 4 of them (1.8%), the arrhythmia was confirmed by the ECG. Patients with AF were more likely to be older (77.0±1.2 vs 57.2±15.2 years, p=0.010), obese (50.0 vs 14.4%, p=0.048) and to suffer from a cardiovascular disease (50.0 vs 10.6%, p=0.014) than patients without AF. Participants with a positive BP AF reading and non-AF arrhythmias (n=8) did not differ in their general characteristics from participants with a negative BP AF reading and were younger than patients with AF (mean age 56.4±14.8, p=0.027; 5 of 8 participants aged <65 years). Opportunistic screening of AF by BP measurement is feasible to diagnose this arrhythmia in unaware participants, particularly in those older than 65 years, who are the target patient group recommended by current AF screening guidelines. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  11. Blood Culture Testing via a Mobile App That Uses a Mobile Phone Camera: A Feasibility Study

    PubMed Central

    Chong, Yong Pil; Jang, Seongsoo; Kim, Mi Na; Kim, Jeong Hoon; Kim, Woo Sung

    2016-01-01

    Background To evaluate patients with fever of unknown origin or those with suspected bacteremia, the precision of blood culture tests is critical. An inappropriate step in the test process or error in a parameter could lead to a false-positive result, which could then affect the direction of treatment in critical conditions. Mobile health apps can be used to resolve problems with blood culture tests, and such apps can hence ensure that point-of-care guidelines are followed and processes are monitored for blood culture tests. Objective In this pilot project, we aimed to investigate the feasibility of using a mobile blood culture app to manage blood culture test quality. We implemented the app at a university hospital in South Korea to assess the potential for its utilization in a clinical environment by reviewing the usage data among a small group of users and by assessing their feedback and the data related to blood culture sampling. Methods We used an iOS-based blood culture app that uses an embedded camera to scan the patient identification and sample number bar codes. A total of 4 medical interns working at 2 medical intensive care units (MICUs) participated in this project, which spanned 3 weeks. App usage and blood culture sampling parameters (including sampler, sampling site, sampling time, and sample volume) were analyzed. The compliance of sampling parameter entry was also measured. In addition, the participants’ opinions regarding patient safety, timeliness, efficiency, and usability were recorded. Results In total, 356/644 (55.3%) of all blood culture samples obtained at the MICUs were examined using the app, including 254/356 (71.3%) with blood collection volumes of 5-7 mL and 256/356 (71.9%) with blood collection from the peripheral veins. The sampling volume differed among the participants. Sampling parameters were completely entered in 354/356 cases (99.4%). All the participants agreed that the app ensured good patient safety, disagreed on its timeliness, and did not believe that it was efficient. Although the bar code scanning speed was acceptable, the Wi-Fi environment required improvement. Moreover, the participants requested feedback regarding their sampling quality. Conclusions Although this app could be used in the clinical setting, improvements in the app functions, environment network, and internal policy of blood culture testing are needed to ensure hospital-wide use. PMID:27784649

  12. Blood Culture Testing via a Mobile App That Uses a Mobile Phone Camera: A Feasibility Study.

    PubMed

    Lee, Guna; Lee, Yura; Chong, Yong Pil; Jang, Seongsoo; Kim, Mi Na; Kim, Jeong Hoon; Kim, Woo Sung; Lee, Jae-Ho

    2016-10-26

    To evaluate patients with fever of unknown origin or those with suspected bacteremia, the precision of blood culture tests is critical. An inappropriate step in the test process or error in a parameter could lead to a false-positive result, which could then affect the direction of treatment in critical conditions. Mobile health apps can be used to resolve problems with blood culture tests, and such apps can hence ensure that point-of-care guidelines are followed and processes are monitored for blood culture tests. In this pilot project, we aimed to investigate the feasibility of using a mobile blood culture app to manage blood culture test quality. We implemented the app at a university hospital in South Korea to assess the potential for its utilization in a clinical environment by reviewing the usage data among a small group of users and by assessing their feedback and the data related to blood culture sampling. We used an iOS-based blood culture app that uses an embedded camera to scan the patient identification and sample number bar codes. A total of 4 medical interns working at 2 medical intensive care units (MICUs) participated in this project, which spanned 3 weeks. App usage and blood culture sampling parameters (including sampler, sampling site, sampling time, and sample volume) were analyzed. The compliance of sampling parameter entry was also measured. In addition, the participants' opinions regarding patient safety, timeliness, efficiency, and usability were recorded. In total, 356/644 (55.3%) of all blood culture samples obtained at the MICUs were examined using the app, including 254/356 (71.3%) with blood collection volumes of 5-7 mL and 256/356 (71.9%) with blood collection from the peripheral veins. The sampling volume differed among the participants. Sampling parameters were completely entered in 354/356 cases (99.4%). All the participants agreed that the app ensured good patient safety, disagreed on its timeliness, and did not believe that it was efficient. Although the bar code scanning speed was acceptable, the Wi-Fi environment required improvement. Moreover, the participants requested feedback regarding their sampling quality. Although this app could be used in the clinical setting, improvements in the app functions, environment network, and internal policy of blood culture testing are needed to ensure hospital-wide use.

  13. Isolation of human genomic DNA for genetic analysis from premature neonates: a comparison between newborn dried blood spots, whole blood and umbilical cord tissue

    PubMed Central

    2013-01-01

    Background Genotyping requires biological sample collection that must be reliable, convenient and acceptable for patients and clinicians. Finding the most optimal procedure of sample collection for premature neonates who have a very limited blood volume is a particular challenge. The aim of the current study was to evaluate the use of umbilical cord (UC) tissue and newborn dried blood spot (DBS)-extracted genomic DNA (gDNA) as an alternative to venous blood-derived gDNA from premature neonates for molecular genetic analysis. All samples were obtained from premature newborn infants between 24-32 weeks of gestation. Paired blood and UC samples were collected from 31 study participants. gDNA was extracted from ethylenediaminetetraacetic acid (EDTA) anticoagulant-treated blood samples (~500 μl) and newborn DBSs (n = 723) using QIAamp DNA Micro kit (Qiagen Ltd., Crawley, UK); and from UC using Qiagen DNAeasy Blood and Tissue kit (Qiagen Ltd., Crawley, UK). gDNA was quantified and purity confirmed by measuring the A260:A280 ratio. PCR amplification and pyrosequencing was carried out to determine suitability of the gDNA for molecular genetic analysis. Minor allele frequency of two unrelated single nucleotide polymorphisms (SNPs) was calculated using the entire cohort. Results Both whole blood samples and UC tissue provided good quality and yield of gDNA, which was considerably less from newborn DBS. The gDNA purity was also reduced after 3 years of storage of the newborn DBS. PCR amplification of three unrelated genes resulted in clear products in all whole blood and UC samples and 86%-100% of newborn DBS. Genotyping using pyrosequencing showed 100% concordance in the paired UC and whole blood samples. Minor allele frequencies of the two SNPs indicated that no maternal gDNA contamination occurred in the genotyping of the UC samples. Conclusions gDNAs from all three sources are suitable for standard PCR and pyrosequencing assays. Given that UC provide good quality and quantity gDNA with 100% concordance in the genetic analysis with whole blood, it can replace blood sampling from premature infants. This is likely to reduce the stress and potential side effects associated with invasive sample collection and thus, greatly facilitate participant recruitment for genetic studies. PMID:24168095

  14. Real-time monitoring of hemodynamic changes in tumor vessels during photoimmunotherapy using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Liang, Chia-Pin; Nakajima, Takahito; Watanabe, Rira; Sato, Kazuhide; Choyke, Peter L.; Chen, Yu; Kobayashi, Hisataka

    2014-09-01

    Photoimmunotherapy (PIT) is a cell-specific cancer therapy based on an armed antibody conjugate that induces rapid and highly selective cancer cell necrosis after exposure to near-infrared (NIR) light. The PIT treatment also induces the superenhanced permeability and retention effect, which allows high concentrations of nanoparticles to accumulate in the tumor bed. In our pilot studies, optical coherence tomography (OCT) reveals dramatic hemodynamic changes during PIT. We developed and applied speckle variance analysis, Doppler flow measurement, bulk motion removal, and automatic region of interest selection to quantify vessel diameter and blood velocity within tumors in vivo. OCT imaging reveals that blood velocity in peripheral tumor vessels quickly drops below the detection limit while the vessel lumen remains open (4 vessels from 3 animals). On the other hand, control tumor vessels (receive NIR illumination but no PIT drug) do not show the sustained blood velocity drop (5 vessels from 3 animals). Ultraslow blood velocity could result in a long drug circulation time in tumor. Increase of the blood pool volume within the central tumor (shown in histology) may be the leading cause of the periphery blood velocity drop and could also increase the drug pool volume in tumor vessels.

  15. Real-time PCR detection of Plasmodium directly from whole blood and filter paper samples

    PubMed Central

    2011-01-01

    Background Real-time PCR is a sensitive and specific method for the analysis of Plasmodium DNA. However, prior purification of genomic DNA from blood is necessary since PCR inhibitors and quenching of fluorophores from blood prevent efficient amplification and detection of PCR products. Methods Reagents designed to specifically overcome PCR inhibition and quenching of fluorescence were evaluated for real-time PCR amplification of Plasmodium DNA directly from blood. Whole blood from clinical samples and dried blood spots collected in the field in Colombia were tested. Results Amplification and fluorescence detection by real-time PCR were optimal with 40× SYBR® Green dye and 5% blood volume in the PCR reaction. Plasmodium DNA was detected directly from both whole blood and dried blood spots from clinical samples. The sensitivity and specificity ranged from 93-100% compared with PCR performed on purified Plasmodium DNA. Conclusions The methodology described facilitates high-throughput testing of blood samples collected in the field by fluorescence-based real-time PCR. This method can be applied to a broad range of clinical studies with the advantages of immediate sample testing, lower experimental costs and time-savings. PMID:21851640

  16. Automatic Extraction of Myocardial Mass and Volume Using Parametric Images from Dynamic Nongated PET.

    PubMed

    Harms, Hendrik Johannes; Stubkjær Hansson, Nils Henrik; Tolbod, Lars Poulsen; Kim, Won Yong; Jakobsen, Steen; Bouchelouche, Kirsten; Wiggers, Henrik; Frøkiaer, Jørgen; Sörensen, Jens

    2016-09-01

    Dynamic cardiac PET is used to quantify molecular processes in vivo. However, measurements of left ventricular (LV) mass and volume require electrocardiogram-gated PET data. The aim of this study was to explore the feasibility of measuring LV geometry using nongated dynamic cardiac PET. Thirty-five patients with aortic-valve stenosis and 10 healthy controls underwent a 27-min (11)C-acetate PET/CT scan and cardiac MRI (CMR). The controls were scanned twice to assess repeatability. Parametric images of uptake rate K1 and the blood pool were generated from nongated dynamic data. Using software-based structure recognition, the LV wall was automatically segmented from K1 images to derive functional assessments of LV mass (mLV) and wall thickness. End-systolic and end-diastolic volumes were calculated using blood pool images and applied to obtain stroke volume and LV ejection fraction (LVEF). PET measurements were compared with CMR. High, linear correlations were found for LV mass (r = 0.95), end-systolic volume (r = 0.93), and end-diastolic volume (r = 0.90), and slightly lower correlations were found for stroke volume (r = 0.74), LVEF (r = 0.81), and thickness (r = 0.78). Bland-Altman analyses showed significant differences for mLV and thickness only and an overestimation for LVEF at lower values. Intra- and interobserver correlations were greater than 0.95 for all PET measurements. PET repeatability accuracy in the controls was comparable to CMR. LV mass and volume are accurately and automatically generated from dynamic (11)C-acetate PET without electrocardiogram gating. This method can be incorporated in a standard routine without any additional workload and can, in theory, be extended to other PET tracers. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  17. Blood oxygen saturation determined by transmission spectrophotometry of hemolyzed blood samples

    NASA Technical Reports Server (NTRS)

    Malik, W. M.

    1967-01-01

    Use of the Lambert-Beer Transmission Law determines blood oxygen saturation of hemolyzed blood samples. This simplified method is based on the difference in optical absorption properties of hemoglobin and oxyhemoglobin.

  18. Use of intumescent compounds in fire curtains

    NASA Astrophysics Data System (ADS)

    Nedryshkin, Oleg; Gravit, Marina; Mukhamedzhanova, Olga

    2017-10-01

    Automatic fire curtains are designed to divide sections of premises and structures into fire compartments for the purpose of localizing a fire, as well as filling openings in fire barriers. If a fire occurs due to a signal from a fire alarm sensor or a signal from a fire station, the blind automatically falls and locates the source of ignition. The paper presents the results of testing nine samples of fire curtains with an applied intumescent composition. Tests were conducted for 60 minutes before loss of sample integrity. The average temperature from the heated side of the sample reached 800 ∼ 1000 ° C. Depending on the sample, the temperature from the unheated side ranged from 70 ° C to 294 ° C. The best result was shown by a sample from a layer of needle-punched heat-insulating material with a thermal conductivity of 0.036 W/(m×K) placed between layers of foil and treated with water-based intumescent composition of silica material.

  19. Automatic and objective oral cancer diagnosis by Raman spectroscopic detection of keratin with multivariate curve resolution analysis

    NASA Astrophysics Data System (ADS)

    Chen, Po-Hsiung; Shimada, Rintaro; Yabumoto, Sohshi; Okajima, Hajime; Ando, Masahiro; Chang, Chiou-Tzu; Lee, Li-Tzu; Wong, Yong-Kie; Chiou, Arthur; Hamaguchi, Hiro-O.

    2016-01-01

    We have developed an automatic and objective method for detecting human oral squamous cell carcinoma (OSCC) tissues with Raman microspectroscopy. We measure 196 independent Raman spectra from 196 different points of one oral tissue sample and globally analyze these spectra using a Multivariate Curve Resolution (MCR) analysis. Discrimination of OSCC tissues is automatically and objectively made by spectral matching comparison of the MCR decomposed Raman spectra and the standard Raman spectrum of keratin, a well-established molecular marker of OSCC. We use a total of 24 tissue samples, 10 OSCC and 10 normal tissues from the same 10 patients, 3 OSCC and 1 normal tissues from different patients. Following the newly developed protocol presented here, we have been able to detect OSCC tissues with 77 to 92% sensitivity (depending on how to define positivity) and 100% specificity. The present approach lends itself to a reliable clinical diagnosis of OSCC substantiated by the “molecular fingerprint” of keratin.

  20. Integration and segregation of large-scale brain networks during short-term task automatization

    PubMed Central

    Mohr, Holger; Wolfensteller, Uta; Betzel, Richard F.; Mišić, Bratislav; Sporns, Olaf; Richiardi, Jonas; Ruge, Hannes

    2016-01-01

    The human brain is organized into large-scale functional networks that can flexibly reconfigure their connectivity patterns, supporting both rapid adaptive control and long-term learning processes. However, it has remained unclear how short-term network dynamics support the rapid transformation of instructions into fluent behaviour. Comparing fMRI data of a learning sample (N=70) with a control sample (N=67), we find that increasingly efficient task processing during short-term practice is associated with a reorganization of large-scale network interactions. Practice-related efficiency gains are facilitated by enhanced coupling between the cingulo-opercular network and the dorsal attention network. Simultaneously, short-term task automatization is accompanied by decreasing activation of the fronto-parietal network, indicating a release of high-level cognitive control, and a segregation of the default mode network from task-related networks. These findings suggest that short-term task automatization is enabled by the brain's ability to rapidly reconfigure its large-scale network organization involving complementary integration and segregation processes. PMID:27808095

  1. A rapid, highly sensitive and culture-free detection of pathogens from blood by positive enrichment.

    PubMed

    Vutukuru, Manjula Ramya; Sharma, Divya Khandige; Ragavendar, M S; Schmolke, Susanne; Huang, Yiwei; Gumbrecht, Walter; Mitra, Nivedita

    2016-12-01

    Molecular diagnostics is a promising alternative to culture based methods for the detection of bloodstream infections, notably due to its overall lower turnaround time when starting directly from patient samples. Whole blood is usually the starting diagnostic sample in suspected bloodstream infections. The detection of low concentrations of pathogens in blood using a molecular assay necessitates a fairly high starting volume of blood sample in the range of 5-10mL. This large volume of blood sample has a substantial accompanying human genomic content that interferes with pathogen detection. In this study, we have established a workflow using magnetic beads coated with Apolipoprotein H that makes it possible to concentrate pathogens from a 5.0mL whole blood sample, thereby enriching pathogens from whole blood background and also reducing the sample volume to ~200μL or less. We have also demonstrated that this method of enrichment allows detection of 1CFU/mL of Escherichia coli, Enterococcus gallinarum and Candida tropicalis from 5mL blood using quantitative PCR; a detection limit that is not possible in unenriched samples. The enrichment method demonstrated here took 30min to complete and can be easily integrated with various downstream molecular and microbiological techniques. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 86 blood samples over 86 households. Each sample was collected as a venous sample from the primary respondent within each household. The samples consisted of two 3-mL tubes. The prim...

  3. [Identification of Animal Whole Blood Based on Near Infrared Transmission Spectroscopy].

    PubMed

    Wan, Xiong; Wang, Jian; Liu, Peng-xi; Zhang, Ting-ting

    2016-01-01

    The inspection and classification for blood products are important but complicated in import-export ports or inspection and quarantine departments. For the inspection of whole blood products, open sampling can cause pollution and virulence factors in bloods samples may even endanger inspectors. Thus non-contact classification and identification methods for whole bloods of animals are needed. Spectroscopic techniques adopted in the flowcytometry need sampling blood cells during the detection; therefore they can not meet the demand of non-contact identification and classification for whole bloods of animals. Infrared absorption spectroscopy is a technique that can be used to analyze the molecular structure and chemical bonds of detected samples under the condition of non-contact. To find a feasible spectroscopic approach of non-contact detection for the species variation in whole blood samples, a near infrared transmitted spectra (NITS, 4 497.669 - 7 506.4 cm(-1)) experiment of whole blood samples of three common animals including chickens, dogs and cats has been conducted. During the experiment, the spectroscopic resolution is 5 cm(-1), and each spectrogram is an average of 5 measured spectral data. Experimental results show that all samples have a sharp absorption peak between 5 184 and 5 215 cm(-1), and a gentle absorption peak near 7 000 cm(-1). Besides, the NITS curves of different samples of same animals are similar, and only have slight differences in the whole transmittance. A correlation coefficient (CC) is induced to distinguish the differences of the three animals' whole bloods in NITS curves, and the computed CCs between NITS curves of different samples of the same animals, are greater than 0.99, whereas CCs between NITS curves of the whole bloods of different animals are from 0.509 48 to 0.916 13. Among which CCs between NITS curves of the whole bloods of chickens and cats are from 0.857 23 to 0.912 44, CCs between NITS curves of the whole bloods of chickens and dogs are from 0.509 48 to 0.664 82, and CCs between NITS curves of the whole bloods of cats and dogs are from 0.872 75 to 0.916 13. The cat and the dog belong to the class of mammal, and the CCs between their whole bloods NITS curves are greater than those between chickens and cats, or chickens and dogs, which are hetero-class animals. Namely, the whole bloods NITS curves of the cat and the dog have higher similarity. These results of NITS provide a feasible method of non-contact identification of animal whole bloods.

  4. The role of the medical laboratory technologist in drinking and driving cases. Part 1: The Criminal Code and blood collection for alcohol analysis.

    PubMed

    Westenbrink, W

    1992-01-01

    Police officers can now demand blood samples from suspected impaired drivers in Canada to determine their Blood Alcohol Concentration. The medical laboratory technologist has been given the authority to take blood samples for legal purposes, as well as the authorization to complete certificates used as evidence in court. The proper procedures for the taking of blood samples and the completion of certificates are described in detail. The Criminal Code offences dealing with drinking and driving, the means by which police officers can legally obtain blood samples, the Blood Alcohol Kit, and the provision of providing blood collection evidence in court are discussed to aid the technologists in understanding their role in this process. The Criminal Code definitions of a "qualified medical practitioner", a "qualified technician", and "approved containers" are also described.

  5. An automatic vision-based malaria diagnosis system.

    PubMed

    Vink, J P; Laubscher, M; Vlutters, R; Silamut, K; Maude, R J; Hasan, M U; DE Haan, G

    2013-06-01

    Malaria is a worldwide health problem with 225 million infections each year. A fast and easy-to-use method, with high performance is required to differentiate malaria from non-malarial fevers. Manual examination of blood smears is currently the gold standard, but it is time-consuming, labour-intensive, requires skilled microscopists and the sensitivity of the method depends heavily on the skills of the microscopist. We propose an easy-to-use, quantitative cartridge-scanner system for vision-based malaria diagnosis, focusing on low malaria parasite densities. We have used special finger-prick cartridges filled with acridine orange to obtain a thin blood film and a dedicated scanner to image the cartridge. Using supervised learning, we have built a Plasmodium falciparum detector. A two-step approach was used to first segment potentially interesting areas, which are then analysed in more detail. The performance of the detector was validated using 5,420 manually annotated parasite images from malaria parasite culture in medium, as well as using 40 cartridges of 11,780 images containing healthy blood. From finger prick to result, the prototype cartridge-scanner system gave a quantitative diagnosis in 16 min, of which only 1 min required manual interaction of basic operations. It does not require a wet lab or a skilled operator and provides parasite images for manual review and quality control. In healthy samples, the image analysis part of the system achieved an overall specificity of 99.999978% at the level of (infected) red blood cells, resulting in at most seven false positives per microlitre. Furthermore, the system showed a sensitivity of 75% at the cell level, enabling the detection of low parasite densities in a fast and easy-to-use manner. A field trial in Chittagong (Bangladesh) indicated that future work should primarily focus on improving the filling process of the cartridge and the focus control part of the scanner. © 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.

  6. Analytical and pre-analytical performance characteristics of a novel cartridge-type blood gas analyzer for point-of-care and laboratory testing.

    PubMed

    Oyaert, Matthijs; Van Maerken, Tom; Bridts, Silke; Van Loon, Silvi; Laverge, Heleen; Stove, Veronique

    2018-03-01

    Point-of-care blood gas test results may benefit therapeutic decision making by their immediate impact on patient care. We evaluated the (pre-)analytical performance of a novel cartridge-type blood gas analyzer, the GEM Premier 5000 (Werfen), for the determination of pH, partial carbon dioxide pressure (pCO 2 ), partial oxygen pressure (pO 2 ), sodium (Na + ), potassium (K + ), chloride (Cl - ), ionized calcium ( i Ca 2+ ), glucose, lactate, and total hemoglobin (tHb). Total imprecision was estimated according to the CLSI EP5-A2 protocol. The estimated total error was calculated based on the mean of the range claimed by the manufacturer. Based on the CLSI EP9-A2 evaluation protocol, a method comparison with the Siemens RapidPoint 500 and Abbott i-STAT CG8+ was performed. Obtained data were compared against preset quality specifications. Interference of potential pre-analytical confounders on co-oximetry and electrolyte concentrations were studied. The analytical performance was acceptable for all parameters tested. Method comparison demonstrated good agreement to the RapidPoint 500 and i-STAT CG8+, except for some parameters (RapidPoint 500: pCO 2 , K + , lactate and tHb; i-STAT CG8+: pO 2 , Na + , i Ca 2+ and tHb) for which significant differences between analyzers were recorded. No interference of lipemia or methylene blue on CO-oximetry results was found. On the contrary, significant interference for benzalkonium and hemolysis on electrolyte measurements were found, for which the user is notified by an interferent specific flag. Identification of sample errors from pre-analytical sources, such as interferences and automatic corrective actions, along with the analytical performance, ease of use and low maintenance time of the instrument, makes the evaluated instrument a suitable blood gas analyzer for both POCT and laboratory use. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. Compare the efficacy of inhaled budesonide and systemic methylprednisolone on systemic inflammation of AECOPD.

    PubMed

    Sun, Xuejiao; He, Zhiyi; Zhang, Jianquan; Deng, Jingmin; Bai, Jing; Li, Meihua; Zhong, Xiaoning

    2015-04-01

    Corticosteroids have been shown to improve the outcome of acute exacerbation of chronic obstructive pulmonary disease (AECOPD). However, whether inhaled corticosteroids (IC) alone have similar effects with systemic corticosteroid (SCS) is still unclear. To compare the efficacy of inhaled budesonide and systemic methylprednisolone on systemic inflammation of AECOPD. 30 AECOPD patients were randomly divided into two group. Budesonide group (15 cases) were treated with inhaled budesonide (3 mg Bid); methylprednisolone group (15 cases) were treated with systemic methylprednisolone (methylprednisolone acetate injectable suspension 40 mg Qd for three days and then methylprednisolone tablets 8 mg Bid). Observe symptoms, lung function, blood gas analysis and adverse effects of the patients in two groups. Peripheral blood samples were collected before and after treatment for 1 day, 4 days and 7 days. Interleukin-8 (IL-8) and TNF-α levels were determined by an enzyme linked immunosorbent assay (ELISA). Hs-CRP levels were detected by automatic biochemical analyzer. Western blotting was used to determine histone deacetylase 2 (HDAC2) protein expression. Symptoms, pulmonary function and blood gas analysis were significantly improved after treatment in the two groups (P < 0.05) and no significant differences between the two groups (P > 0.05). There were no significant differences of IL-8, TNF-α and hs-CRP levels in the two groups (P > 0.05). Besides, the levels of HDAC2 protein expression before treatment were significantly lower comparing to that after treatment for 4 and 7 days. Incidence of adverse events (heart rate, blood pressure, glycemic, sleep condition, gastrointestinal symptoms) in budesonide group was lower than methylprednisolone group (P < 0.05). Inhaled budesonide and systemic methylprednisolone have the same effects on systemic inflammation of AECOPD. Inhaled corticosteroid alone could instead systemic corticosteroid in AECOPD treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Comparison of blood chemistry values for samples collected from juvenile chinook salmon by three methods

    USGS Publications Warehouse

    Congleton, J.L.; LaVoie, W.J.

    2001-01-01

    Thirteen blood chemistry indices were compared for samples collected by three commonly used methods: caudal transection, heart puncture, and caudal vessel puncture. Apparent biases in blood chemistry values for samples obtained by caudal transection were consistent with dilution with tissue fluids: alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), creatine kinase (CK), triglyceride, and K+ were increased and Na+ and Cl- were decreased relative to values for samples obtained by caudal vessel puncture. Some enzyme activities (ALT, AST, LDH) and K+ concentrations were also greater in samples taken by heart puncture than in samples taken by caudal vessel puncture. Of the methods tested, caudal vessel puncture had the least effect on blood chemistry values and should be preferred for blood chemistry studies on juvenile salmonids.

  9. NHEXAS PHASE I REGION 5 STUDY--METALS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    This data set includes analytical results for measurements of metals in 165 blood samples. These samples were collected to examine the relationships between personal exposure measurements, environmental measurements, and body burden. Venous blood samples were collected by venipun...

  10. NHEXAS PHASE I REGION 5 STUDY--VOCS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    This data set includes analytical results for measurements of VOCs (volatile organic compounds) in 145 blood samples. These samples were collected to examine the relationships between personal exposure measurements, environmental measurements, and body burden. Venous blood sample...

  11. Hematological parameters of human immunodeficiency virus positive pregnant women on antiretroviral therapy in Aminu Kano Teaching Hospital Kano, North Western Nigeria.

    PubMed

    Abdulqadir, Ibrahim; Ahmed, Sagir Gumel; Kuliya, Aisha Gwarzo; Tukur, Jamilu; Yusuf, Aminu Abba; Musa, Abubakar Umar

    2018-01-01

    Human immunodeficiency virus (HIV) scourge continues to affect young women within the reproductive age group and pregnancy is a recognized indication for the use antiretroviral (ARV) drugs among HIV-positive women. The aim is to determine the combined effect of pregnancy, HIV and ARV drugs on the hematological parameters of the pregnant women. This was a comparative cross-sectional study conducted among 70 each of HIV-positive and negative pregnant women. Bio-demographic and clinical data were extracted from the client folder and 4 ml of blood sample was obtained from each participant. Full blood count was generated using Swelab automatic hematology analyzer while reticulocyte count and erythrocyte sedimentation rate (ESR) were conducted manually. Data analysis was performed using SPSS version software 16 while P < 0.05 was considered statistically significant. Pregnant women with HIV had statistically significant lower hematocrit and white blood cell (WBC) and higher ESR than pregnant women without HIV ( P < 0.000). There was no statistically significant difference between the two groups in terms of platelet and reticulocyte ( P > 0.05). However, among HIV positive pregnant women, those with CD4 count <350/μL had statistically significant lower WBC and lymphocyte count than those with CD4 count ≥350/μL ( P < 0.05), whereas, those on zidovudine (AZT)-containing treatment had statistically significant lower hematocrit and higher mean cell volume than those on non-AZT-containing treatment ( P < 0.05), but there was no statistically significant difference in any of the hematological parameters ( P > 0.050) between women on first- and second-line ARV regimens. There is a significant difference in terms of hematological parameters between HIV-positive and HIV-negative pregnant women in this environment.

  12. Shunt flow evaluation in congenital heart disease based on two-dimensional speckle tracking.

    PubMed

    Fadnes, Solveig; Nyrnes, Siri Ann; Torp, Hans; Lovstakken, Lasse

    2014-10-01

    High-frame-rate ultrasound speckle tracking was used for quantification of peak velocity in shunt flows resulting from septal defects in congenital heart disease. In a duplex acquisition scheme implemented on a research scanner, unfocused transmit beams and full parallel receive beamforming were used to achieve a frame rate of 107 frames/s for full field-of-view flow images with high accuracy, while also ensuring high-quality focused B-mode tissue imaging. The setup was evaluated in vivo for neonates with atrial and ventricular septal defects. The shunt position was automatically tracked in B-mode images and further used in blood speckle tracking to obtain calibrated shunt flow velocities throughout the cardiac cycle. Validation toward color flow imaging and pulsed wave Doppler with manual angle correction indicated that blood speckle tracking could provide accurate estimates of shunt flow velocities. The approach was less biased by clutter filtering compared with color flow imaging and was able to provide velocity estimates beyond the Nyquist range. Possible placements of sample volumes (and angle corrections) for conventional Doppler resulted in a peak shunt velocity variations of 0.49-0.56 m/s for the ventricular septal defect of patient 1 and 0.38-0.58 m/s for the atrial septal defect of patient 2. In comparison, the peak velocities found from speckle tracking were 0.77 and 0.33 m/s for patients 1 and 2, respectively. Results indicated that complex intraventricular flow velocity patterns could be quantified using high-frame-rate speckle tracking of both blood and tissue movement. This could potentially help increase diagnostic accuracy and decrease inter-observer variability when measuring peak velocity in shunt flows. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. Dynamic composition of medical support services in the ICU: Platform and algorithm design details.

    PubMed

    Hristoskova, Anna; Moeyersoon, Dieter; Van Hoecke, Sofie; Verstichel, Stijn; Decruyenaere, Johan; De Turck, Filip

    2010-12-01

    The Intensive Care Unit (ICU) is an extremely data-intensive environment where each patient needs to be monitored 24/7. Bedside monitors continuously register vital patient values (such as serum creatinine, systolic blood pressure) which are recorded frequently in the hospital database (e.g. every 2 min in the ICU of the Ghent University Hospital), laboratories generate hundreds of results of blood and urine samples, and nurses measure blood pressure and temperature up to 4 times an hour. The processing of such large amount of data requires an automated system to support the physicians' daily work. The Intensive Care Service Platform (ICSP) offers the needed support through the development of medical support services for processing and monitoring patients' data. With an increased deployment of these medical support services, reusing existing services as building blocks to create new services offers flexibility to the developer and accelerates the design process. This paper presents a new addition to the ICSP, the Dynamic Composer for Web services. Based on a semantic description of the medical support services, this Composer enables a service to be executed by creating a composition of medical services that provide the needed calculations. The composition is achieved using various algorithms satisfying certain quality of service (QoS) constraints and requirements. In addition to the automatic composition the paper also proposes a recovery mechanism in case of unavailable services. When executing the composition of medical services, unavailable services are dynamically replaced by equivalent services or a new composition achieving the same result. The presented platform and QoS algorithms are put through extensive performance and scalability tests for typical ICU scenarios, in which basic medical services are composed to a complex patient monitoring service. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  14. Concentrations of Plasma Free Palmitoleic and Dihomo-Gamma Linoleic Fatty Acids Are Higher in Children with Abdominal Obesity.

    PubMed

    Aristizabal, Juan C; González-Zapata, Laura I; Estrada-Restrepo, Alejandro; Monsalve-Alvarez, Julia; Restrepo-Mesa, Sandra L; Gaitán, Diego

    2018-01-01

    Increased plasma free fatty acids (FFAs) are associated with cardiometabolic risk factors in adults with abdominal obesity (AO). However, this association remains controversial in children. This study analyzed plasma FFA concentration in children with and without AO. Twenty-nine children classified with AO were matched by age and sex with 29 non-obese individuals. Blood samples were collected after fasting for 10-12 h. Plasma concentration of glucose, insulin, triglycerides, total cholesterol, low-density lipoprotein cholesterol (LDL-C), and high-density lipoprotein cholesterol (HDL-C) were determined by automatized methods. FFAs were analyzed by gas chromatography. Children with and without AO had similar age (7.1 ± 2.6 vs. 7.2 ± 2.7 years; p > 0.05) but obese children showed higher ( p < 0.05) body mass index (BMI) (+4.3 kg/m²), systolic blood pressure (+5.1 mmHg), and insulin (+27.8 pmol/L). There were no significant differences in plasma total FFA concentration between groups (1.02 ± 0.61 vs. 0.89 ± 0.37 mmol/L; p > 0.05). However, children with AO had higher palmitoleic acid (0.94 vs. 0.70 wt %; p < 0.05) and dihomo-gamma linoleic acid (DHGL) (2.76 vs. 2.07 wt %; p < 0.05). Palmitoleic and DHGL acids correlated ( p < 0.05) with BMI ( r = 0.397; r = 0.296, respectively) and with waist circumference ( r = 0.380; r = 0.276, respectively). Palmitoleic acid correlated positively with systolic blood pressure ( r = 0.386; p < 0.05) and negatively with HDL-C (-0.572; p < 0.01). In summary, children with AO have higher plasmatic concentrations of free palmitoleic and DHGL fatty acids, which correlate with cardiometabolic risk factors.

  15. Concentrations of Plasma Free Palmitoleic and Dihomo-Gamma Linoleic Fatty Acids Are Higher in Children with Abdominal Obesity

    PubMed Central

    González-Zapata, Laura I.; Estrada-Restrepo, Alejandro; Monsalve-Alvarez, Julia; Restrepo-Mesa, Sandra L.; Gaitán, Diego

    2018-01-01

    Increased plasma free fatty acids (FFAs) are associated with cardiometabolic risk factors in adults with abdominal obesity (AO). However, this association remains controversial in children. This study analyzed plasma FFA concentration in children with and without AO. Twenty-nine children classified with AO were matched by age and sex with 29 non-obese individuals. Blood samples were collected after fasting for 10–12 h. Plasma concentration of glucose, insulin, triglycerides, total cholesterol, low-density lipoprotein cholesterol (LDL-C), and high-density lipoprotein cholesterol (HDL-C) were determined by automatized methods. FFAs were analyzed by gas chromatography. Children with and without AO had similar age (7.1 ± 2.6 vs. 7.2 ± 2.7 years; p > 0.05) but obese children showed higher (p < 0.05) body mass index (BMI) (+4.3 kg/m2), systolic blood pressure (+5.1 mmHg), and insulin (+27.8 pmol/L). There were no significant differences in plasma total FFA concentration between groups (1.02 ± 0.61 vs. 0.89 ± 0.37 mmol/L; p > 0.05). However, children with AO had higher palmitoleic acid (0.94 vs. 0.70 wt %; p < 0.05) and dihomo-gamma linoleic acid (DHGL) (2.76 vs. 2.07 wt %; p < 0.05). Palmitoleic and DHGL acids correlated (p < 0.05) with BMI (r = 0.397; r = 0.296, respectively) and with waist circumference (r = 0.380; r = 0.276, respectively). Palmitoleic acid correlated positively with systolic blood pressure (r = 0.386; p < 0.05) and negatively with HDL-C (−0.572; p < 0.01). In summary, children with AO have higher plasmatic concentrations of free palmitoleic and DHGL fatty acids, which correlate with cardiometabolic risk factors. PMID:29301242

  16. Director, Operational Test and Evaluation FY 2004 Annual Report

    DTIC Science & Technology

    2004-01-01

    HIGH) Space Based Radar (SBR) Sensor Fuzed Weapon (SFW) P3I (CBU-97/B) Small Diameter Bomb (SDB) Secure Mobile Anti-Jam Reliable Tactical Terminal...detection, identification, and sampling capability for both fixed-site and mobile operations. The system must automatically detect and identify up to ten...staffing within the Services. SYSTEM DESCRIPTION AND MISSION The Services envision JCAD as a hand-held device that automatically detects, identifies, and

  17. Applying Independent Verification and Validation to Automatic Test Equipment

    NASA Technical Reports Server (NTRS)

    Calhoun, Cynthia C.

    1997-01-01

    This paper describes a general overview of applying Independent Verification and Validation (IV&V) to Automatic Test Equipment (ATE). The overview is not inclusive of all IV&V activities that can occur or of all development and maintenance items that can be validated and verified, during the IV&V process. A sampling of possible IV&V activities that can occur within each phase of the ATE life cycle are described.

  18. When regulating emotions at work pays off: a diary and an intervention study on emotion regulation and customer tips in service jobs.

    PubMed

    Hülsheger, Ute R; Lang, Jonas W B; Schewe, Anna F; Zijlstra, Fred R H

    2015-03-01

    We investigated the relationship between deep acting, automatic regulation and customer tips with 2 different study designs. The first study was a daily diary study using a sample of Dutch waiters and taxi-drivers and assessed the link of employees' daily self-reported levels of deep acting and automatic regulation with the amount of tips provided by customers (N = 166 measurement occasions nested in 34 persons). Whereas deep acting refers to deliberate attempts to modify felt emotions and involves conscious effort, automatic regulation refers to automated emotion regulatory processes that result in the natural experience of desired emotions and do not involve deliberate control and effort. Multilevel analyses revealed that both types of emotion regulation were positively associated with customer tips. The second study was an experimental field study using a sample of German hairdressers (N = 41). Emotion regulation in terms of both deep acting and automatic regulation was manipulated using a brief self-training intervention and daily instructions to use cognitive change and attentional deployment. Results revealed that participants in the intervention group received significantly more tips than participants in the control group. PsycINFO Database Record (c) 2015 APA, all rights reserved.

  19. Effects of sample handling methods on substance P concentrations and immunoreactivity in bovine blood samples.

    PubMed

    Mosher, Ruby A; Coetzee, Johann F; Allen, Portia S; Havel, James A; Griffith, Gary R; Wang, Chong

    2014-02-01

    To determine the effects of protease inhibitors and holding times and temperatures before processing on the stability of substance P in bovine blood samples. Blood samples obtained from a healthy 6-month-old calf. Blood samples were dispensed into tubes containing exogenous substance P and 1 of 6 degradative enzyme inhibitor treatments: heparin, EDTA, EDTA with 1 of 2 concentrations of aprotinin, or EDTA with 1 of 2 concentrations of a commercially available protease inhibitor cocktail. Plasma was harvested immediately following collection or after 1, 3, 6, 12, or 24 hours of holding at ambient (20.3° to 25.4°C) or ice bath temperatures. Total substance P immunoreactivity was determined with an ELISA; concentrations of the substance P parent molecule, a metabolite composed of the 9 terminal amino acids, and a metabolite composed of the 5 terminal amino acids were determined with liquid chromatography-tandem mass spectrometry. Regarding blood samples processed immediately, no significant differences in substance P concentrations or immunoreactivity were detected among enzyme inhibitor treatments. In blood samples processed at 1 hour of holding, substance P parent molecule concentration was significantly lower for ambient temperature versus ice bath temperature holding conditions; aprotinin was the most effective inhibitor of substance P degradation at the ice bath temperature. The ELISA substance P immunoreactivity was typically lower for blood samples with heparin versus samples with other inhibitors processed at 1 hour of holding in either temperature condition. Results suggested that blood samples should be chilled and plasma harvested within 1 hour after collection to prevent substance P degradation.

  20. Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories.

    PubMed

    Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine

    2010-09-01

    Scand J Caring Sci; 2010; 24; 581-591 
 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories   Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory.   To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories.   Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing.   The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff.   The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.

  1. [Sampling, storage and transport of biological materials collected from living and deceased subjects for determination of concentration levels of ethyl alcohol and similarly acting substances. A proposal of updating the blood and urine sampling protocol].

    PubMed

    Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew

    2007-01-01

    The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.

  2. Automatic Blood Pressure Measurements During Exercise

    NASA Technical Reports Server (NTRS)

    Weaver, Charles S.

    1985-01-01

    Microprocessor circuits and a computer algorithm for automatically measuring blood pressure during ambulatory monitoring and exercise stress testing have been under development at SRI International. A system that records ECG, Korotkov sound, and arm cuff pressure for off-line calculation of blood pressure has been delivered to NASA, and an LSLE physiological monitoring system that performs the algorithm calculations in real-time is being constructed. The algorithm measures the time between the R-wave peaks and the corresponding Korotkov sound on-set (RK-interval). Since the curve of RK-interval versus cuff pressure during deflation is predictable and slowly varying, windows can be set around the curve to eliminate false Korotkov sound detections that result from noise. The slope of this curve, which will generally decrease during exercise, is the inverse of the systolic slope of the brachial artery pulse. In measurements taken during treadmill stress testing, the changes in slopes of subjects with coronary artery disease were markedly different from the changes in slopes of healthy subjects. Measurements of slope and O2 consumption were also made before and after ten days of bed rest during NASA/Ames Research Center bed rest studies. Typically, the maximum rate of O2 consumption during the post-bed rest test is less than the maximum rate during the pre-bed rest test. The post-bed rest slope changes differ from the pre-bed rest slope changes, and the differences are highly correlated with the drop in the maximum rate of O2 consumption. We speculate that the differences between pre- and post-bed rest slopes are due to a drop in heart contractility.

  3. The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test-retest study.

    PubMed

    Petersen, Esben Thade; Mouridsen, Kim; Golay, Xavier

    2010-01-01

    Arterial Spin Labeling (ASL) is a method to measure perfusion using magnetically labeled blood water as an endogenous tracer. Being fully non-invasive, this technique is attractive for longitudinal studies of cerebral blood flow in healthy and diseased individuals, or as a surrogate marker of metabolism. So far, ASL has been restricted mostly to specialist centers due to a generally low SNR of the method and potential issues with user-dependent analysis needed to obtain quantitative measurement of cerebral blood flow (CBF). Here, we evaluated a particular implementation of ASL (called Quantitative STAR labeling of Arterial Regions or QUASAR), a method providing user independent quantification of CBF in a large test-retest study across sites from around the world, dubbed "The QUASAR reproducibility study". Altogether, 28 sites located in Asia, Europe and North America participated and a total of 284 healthy volunteers were scanned. Minimal operator dependence was assured by using an automatic planning tool and its accuracy and potential usefulness in multi-center trials was evaluated as well. Accurate repositioning between sessions was achieved with the automatic planning tool showing mean displacements of 1.87+/-0.95 mm and rotations of 1.56+/-0.66 degrees . Mean gray matter CBF was 47.4+/-7.5 [ml/100 g/min] with a between-subject standard variation SD(b)=5.5 [ml/100 g/min] and a within-subject standard deviation SD(w)=4.7 [ml/100 g/min]. The corresponding repeatability was 13.0 [ml/100 g/min] and was found to be within the range of previous studies.

  4. Computer program for analysis of hemodynamic response to head-up tilt test

    NASA Astrophysics Data System (ADS)

    ŚwiÄ tek, Eliza; Cybulski, Gerard; Koźluk, Edward; PiÄ tkowska, Agnieszka; Niewiadomski, Wiktor

    2014-11-01

    The aim of this work was to create a computer program, written in the MATLAB environment, which enables the visualization and analysis of hemodynamic parameters recorded during a passive tilt test using the CNS Task Force Monitor System. The application was created to help in the assessment of the relationship between the values and dynamics of changes of the selected parameters and the risk of orthostatic syncope. The signal analysis included: R-R intervals (RRI), heart rate (HR), systolic blood pressure (sBP), diastolic blood pressure (dBP), mean blood pressure (mBP), stroke volume (SV), stroke index (SI), cardiac output (CO), cardiac index (CI), total peripheral resistance (TPR), total peripheral resistance index (TPRI), ventricular ejection time (LVET) and thoracic fluid content (TFC). The program enables the user to visualize waveforms for a selected parameter and to perform smoothing with selected moving average parameters. It allows one to construct the graph of means for any range, and the Poincare plot for a selected time range. The program automatically determines the average value of the parameter before tilt, its minimum and maximum value immediately after changing positions and the times of their occurrence. It is possible to correct the automatically detected points manually. For the RR interval, it determines the acceleration index (AI) and the brake index (BI). It is possible to save calculated values to an XLS with a name specified by user. The application has a user-friendly graphical interface and can run on a computer that has no MATLAB software.

  5. Compression and flexural strength of bone cement mixed with blood.

    PubMed

    Tan, J H; Koh, B Th; Ramruttun, A K; Wang, W

    2016-08-01

    To assess the compression and flexural strength of bone cement mixed with 0 ml, 1 ml, or 2 ml of blood. High viscosity polymethyl methacrylate (PMMA) loaded with or without gentamicin was used. Blood was collected from total knee arthroplasty patients. In the same operating room, one pack of cement each was mixed with 0 ml (control), 1 ml, or 2 ml of blood for 1 minute during the dough phase. The dough was extruded into cylindrical and rectangular moulds for 20 minutes of setting, and then cured in phosphate buffered saline at 37±1ºC for 7 days. The samples were visually inspected for fractures and areas of weakness, and then scanned using microcomputed tomography. 48 gentamicin-loaded and 59 non-gentamicin-loaded samples mixed with 0 ml (control), 1 ml, or 2 ml of blood were randomised for flexural and compression strength testing; each group had at least 6 samples. In samples loaded with or without gentamicin, the flexural and compressive strength was highest in controls, followed by samples mixed with 1 ml or 2 ml of blood. In samples mixed with 2 ml of blood, the flexural strength fell below the standard of 50 MPa. In samples mixed with 2 ml of blood and all gentamicin-loaded samples, the compressive strength fell below the standard of 70 MPa. Microcomputed tomography revealed areas of voids and pores indicating the presence of laminations and partitions within. The biomechanical strength of PMMA contaminated with blood may decrease. Precautions such as saline lavage, pack drying the bone, change of gloves, and prompt insertion of the implant should be taken to prevent blood from contaminating bone cement.

  6. Integrated Blood Barcode Chips

    PubMed Central

    Fan, Rong; Vermesh, Ophir; Srivastava, Alok; Yen, Brian K.H.; Qin, Lidong; Ahmad, Habib; Kwong, Gabriel A.; Liu, Chao-Chao; Gould, Juliane; Hood, Leroy; Heath, James R.

    2008-01-01

    Blood comprises the largest version of the human proteome1. Changes of plasma protein profiles can reflect physiological or pathological conditions associated with many human diseases, making blood the most important fluid for clinical diagnostics2-4. Nevertheless, only a handful of plasma proteins are utilized in routine clinical tests. This is due to a host of reasons, including the intrinsic complexity of the plasma proteome1, the heterogeneity of human diseases and the fast kinetics associated with protein degradation in sampled blood5. Simple technologies that can sensitively sample large numbers of proteins over broad concentration ranges, from small amounts of blood, and within minutes of sample collection, would assist in solving these problems. Herein, we report on an integrated microfluidic system, called the Integrated Blood Barcode Chip (IBBC). It enables on-chip blood separation and the rapid measurement of a panel of plasma proteins from small quantities of blood samples including a fingerprick of whole blood. This platform holds potential for inexpensive, non-invasive, and informative clinical diagnoses, particularly, for point-of-care. PMID:19029914

  7. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    NASA Astrophysics Data System (ADS)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  8. Whole blood analysis rotor assembly having removable cellular sedimentation bowl

    DOEpatents

    Burtis, C.A.; Johnson, W.F.

    1975-08-26

    A rotor assembly for performing photometric analyses using whole blood samples is described. Following static loading of a gross blood sample within a centrally located, removable, cell sedimentation bowl, the red blood cells in the gross sample are centrifugally separated from the plasma, the plasm displaced from the sedimentation bowl, and measured subvolumes of plasma distributed to respective sample analysis cuvettes positioned in an annular array about the rotor periphery. Means for adding reagents to the respective cuvettes are also described. (auth)

  9. Detection of defects in laser powder deposition (LPD) components by pulsed laser transient thermography

    NASA Astrophysics Data System (ADS)

    Santospirito, S. P.; Słyk, Kamil; Luo, Bin; Łopatka, Rafał; Gilmour, Oliver; Rudlin, John

    2013-05-01

    Detection of defects in Laser Powder Deposition (LPD) produced components has been achieved by laser thermography. An automatic in-process NDT defect detection software system has been developed for the analysis of laser thermography to automatically detect, reliably measure and then sentence defects in individual beads of LPD components. A deposition path profile definition has been introduced so all laser powder deposition beads can be modeled, and the inspection system has been developed to automatically generate an optimized inspection plan in which sampling images follow the deposition track, and automatically control and communicate with robot-arms, the source laser and cameras to implement image acquisition. Algorithms were developed so that the defect sizes can be correctly evaluated and these have been confirmed using test samples. Individual inspection images can also be stitched together for a single bead, a layer of beads or multiple layers of beads so that defects can be mapped through the additive process. A mathematical model was built up to analyze and evaluate the movement of heat throughout the inspection bead. Inspection processes were developed and positional and temporal gradient algorithms have been used to measure the flaw sizes. Defect analysis is then performed to determine if the defect(s) can be further classified (crack, lack of fusion, porosity) and the sentencing engine then compares the most significant defect or group of defects against the acceptance criteria - independent of human decisions. Testing on manufactured defects from the EC funded INTRAPID project has successful detected and correctly sentenced all samples.

  10. Mechanisms of red blood cells agglutination in antibody-treated paper.

    PubMed

    Jarujamrus, Purim; Tian, Junfei; Li, Xu; Siripinyanond, Atitaya; Shiowatana, Juwadee; Shen, Wei

    2012-05-07

    Recent reports on using bio-active paper and bio-active thread to determine human blood type have shown a tremendous potential of using these low-cost materials to build bio-sensors for blood diagnosis. In this work we focus on understanding the mechanisms of red blood cell agglutination in the antibody-loaded paper. We semi-quantitatively evaluate the percentage of antibody molecules that are adsorbed on cellulose fibres and can potentially immobilize red blood cells on the fibre surface, and the percentage of the molecules that can desorb from the cellulose fibre surface into the blood sample and cause haemagglutination reaction in the bulk of a blood sample. Our results show that 34 to 42% of antibody molecules in the papers treated with commercial blood grouping antibodies can desorb from the fibre surface. When specific antibody molecules are released into the blood sample via desorption, haemagglutination reaction occurs in the blood sample. The reaction bridges the red cells in the blood sample bulk to the layer of red cells immobilized on the fibre surface by the adsorbed antibody molecules. The desorbed antibody also causes agglutinated lumps of red blood cells to form. These lumps cannot pass through the pores of the filter paper. The immobilization and filtration of agglutinated red cells give reproducible identification of positive haemagglutination reaction. Results from this study provide information for designing new bio-active paper-based devices for human blood typing with improved sensitivity and specificity.

  11. Energy dispersive X-ray fluorescence spectrometry for the direct multi-element analysis of dried blood spots

    NASA Astrophysics Data System (ADS)

    Marguí, E.; Queralt, I.; García-Ruiz, E.; García-González, E.; Rello, L.; Resano, M.

    2018-01-01

    Home-based collection protocols for clinical specimens are actively pursued as a means of improving life quality of patients. In this sense, dried blood spots (DBS) are proposed as a non-invasive and even self-administered alternative to sampling whole venous blood. This contribution explores the potential of energy dispersive X-ray fluorescence spectrometry for the simultaneous and direct determination of some major (S, Cl, K, Na), minor (P, Fe) and trace (Ca, Cu, Zn) elements in blood, after its deposition onto clinical filter papers, thus giving rise to DBS. For quantification purposes the best strategy was to use matrix-matched blood samples of known analyte concentrations. The accuracy and precision of the method were evaluated by analysis of a blood reference material (Seronorm™ trace elements whole blood L3). Quantitative results were obtained for the determination of P, S, Cl, K and Fe, and limits of detection for these elements were adequate, taking into account their typical concentrations in real blood samples. Determination of Na, Ca, Cu and Zn was hampered by the occurrence of high sample support (Na, Ca) and instrumental blanks (Cu, Zn). Therefore, the quantitative determination of these elements at the levels expected in blood samples was not feasible. The methodology developed was applied to the analysis of several blood samples and the results obtained were compared with those reported by standard techniques. Overall, the performance of the method developed is promising and it could be used to determine the aforementioned elements in blood samples in a simple, fast and economic way. Furthermore, its non-destructive nature enables further analyses by means of complementary techniques to be carried out.

  12. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY-PESTICIDES AND POLYCHLORINATED BIPHENYLS (PCBS) IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticides and PCBs in Blood data set contains analytical results for measurements of up to 11 pesticides and up to 36 PCBs in 86 blood samples over 86 households. Each sample was collected as a venous sample from the primary respondent within each household. The samples co...

  13. Significance of coupling device for vessel anastomosis in esophageal reconstruction.

    PubMed

    Watanabe, Y; Horiuchi, A; Yamamoto, Y; Kikkawa, H; Kusunose, H; Sugishita, H; Sato, K; Yoshida, M; Yukumi, S; Kawachi, K

    2005-01-01

    To prevent an anastomotic failure due to impaired blood supply, several trials have been performed such as preoperative ischemic conditioning by transarterial embolization of the left gastric, right gastric and splenic arteries or microvascular anastomosis. We assess the significance of an automatic anastomotic coupling device for vessel anastomosis, which we have continuously utilized, to simplify the task and shorten the anastomotic time since March 1999. 8 patients who underwent venous anastomosis by an automatic anastomotic coupling device were evaluated for the time of anastomosis, total ischemic time and outcomes. Venous anastomosis was completed within 5 minutes on average. Microscopic arterial anastomosis by hand took 35 minutes on average. For gastric tube reconstruction, venous anastomosis by an automatic coupling device took only 5 minutes. The top of the gastric tube showed congestion before venous anastomosis, but rapidly recovered from it after anastomosis. Postoperative endoscopic observation of the mucosal color of the replaced intestine or gastric tube was started 3 days after surgery and revealed no ischemia or congestion. The postoperative course was uneventful except one case suffering from pneumonia but leakage was not observed in any case. An automatic anastomotic coupling device can perform an easy and reliable vascular anastomosis for patients who undergo esophageal reconstruction. The device may shorten the operating time and consequently the ischemic time of the gastric tube or jejunal or colonic graft, which in turn may lead to a decrease of complications.

  14. Patterns and trends in lead (Pb) concentrations in bald eagle (Haliaeetus leucocephalus) nestlings from the western Great Lakes region.

    PubMed

    Bruggeman, Jason E; Route, William T; Redig, Patrick T; Key, Rebecca L

    2018-04-10

    Most studies examining bald eagle (Haliaeetus leucocephalus) exposure to lead (Pb) have focused on adults that ingested spent Pb ammunition during the fall hunting season, often at clinical or lethal levels. We sampled live bald eagle nestlings along waterbodies to quantify Pb concentrations in 3 national park units and 2 nearby study areas in the western Great Lakes region. We collected 367 bald eagle nestling feather samples over 8 years during spring 2006-2015 and 188 whole blood samples over 4 years during spring 2010-2015. We used Tobit regression models to quantify relationships between Pb concentrations in nestling feathers and blood using study area, year, and nestling attributes as covariates. Pb in nestling feather samples decreased from 2006 to 2015, but there was no trend for Pb in blood samples. Pb concentrations in nestling feather and blood samples were significantly higher in study areas located closer to and within urban areas. Pb in feather and blood samples from the same nestling was positively correlated. Pb in feathers increased with nestling age, but this relationship was not observed for blood. Our results reflect how Pb accumulates in tissues as nestlings grow, with Pb in feathers and blood indexing exposure during feather development and before sampling, respectively. Some nestlings had Pb concentrations in blood that suggested a greater risk to sublethal effects from Pb exposure. Our data provides baselines for Pb concentrations in feathers and blood of nestling bald eagles from a variety of waterbody types spanning remote, lightly populated, and human-dominated landscapes.

  15. Contamination of successive samples in portable pumping systems

    Treesearch

    Robert B. Thomas; Rand E. Eads

    1983-01-01

    Automatic discrete sample pumping systems used to monitor water quality should deliver to storage all materials pumped in a given cycle. If they do not, successive samples will be contaminated, a severe problem with highly variable suspended sediment concentrations in small streams. The cross-contamination characteristics of two small commonly used portable pumping...

  16. Device and method for automated separation of a sample of whole blood into aliquots

    DOEpatents

    Burtis, Carl A.; Johnson, Wayne F.

    1989-01-01

    A device and a method for automated processing and separation of an unmeasured sample of whole blood into multiple aliquots of plasma. Capillaries are radially oriented on a rotor, with the rotor defining a sample chamber, transfer channels, overflow chamber, overflow channel, vent channel, cell chambers, and processing chambers. A sample of whole blood is placed in the sample chamber, and when the rotor is rotated, the blood moves outward through the transfer channels to the processing chambers where the blood is centrifugally separated into a solid cellular component and a liquid plasma component. When the rotor speed is decreased, the plasma component backfills the capillaries resulting in uniform aliquots of plasma which may be used for subsequent analytical procedures.

  17. Automatic flow-batch system for cold vapor atomic absorption spectroscopy determination of mercury in honey from Argentina using online sample treatment.

    PubMed

    Domínguez, Marina A; Grünhut, Marcos; Pistonesi, Marcelo F; Di Nezio, María S; Centurión, María E

    2012-05-16

    An automatic flow-batch system that includes two borosilicate glass chambers to perform sample digestion and cold vapor atomic absorption spectroscopy determination of mercury in honey samples was designed. The sample digestion was performed by using a low-cost halogen lamp to obtain the optimum temperature. Optimization of the digestion procedure was done using a Box-Behnken experimental design. A linear response was observed from 2.30 to 11.20 μg Hg L(-1). The relative standard deviation was 3.20% (n = 11, 6.81 μg Hg L(-1)), the sample throughput was 4 sample h(-1), and the detection limit was 0.68 μg Hg L(-1). The obtained results with the flow-batch method are in good agreement with those obtained with the reference method. The flow-batch system is simple, allows the use of both chambers simultaneously, is seen as a promising methodology for achieving green chemistry goals, and is a good proposal to improving the quality control of honey.

  18. [Blood sampling using "dried blood spot": a clinical biology revolution underway?].

    PubMed

    Hirtz, Christophe; Lehmann, Sylvain

    2015-01-01

    Blood testing using the dried blood spot (DBS) is used since the 1960s in clinical analysis, mainly within the framework of the neonatal screening (Guthrie test). Since then numerous analytes such as nucleic acids, small molecules or lipids, were successfully measured on the DBS. While this pre-analytical method represents an interesting alternative to classic blood sampling, its use in routine is still limited. We review here the different clinical applications of the blood sampling on DBS and estimate its future place, supported by the new methods of analysis as the LC-MS mass spectrometry.

  19. Application of dried blood spot cards to determine olive oil phenols (hydroxytyrosol metabolites) in human blood.

    PubMed

    de Las Hazas, María Carmen López; Motilva, Maria José; Piñol, Carme; Macià, Alba

    2016-10-01

    In this study, a fast and simple blood sampling and sample pre-treatment method based on the use of the dried blood spot (DBS) cards and ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) for the quantification of olive oil phenolic metabolites in human blood was developed and validated. After validation, the method was applied to determine hydroxytyrosol metabolites in human blood samples after the acute intake of an olive oil phenolic extract. Using the FTA DMPK-A DBS card under optimum conditions, with 20µL as the blood solution volume, 100µL of methanol/Milli-Q water (50/50, v/v) as the extraction solvent and 7 disks punched out from the card, the main hydroxytyrosol metabolites (hydroxytyrosol-3-O-sulphate and hydroxytyrosol acetate sulphate) were identified and quantified. The developed methodology allowed detecting and quantifying the generated metabolites at low μM levels. The proposed method is a significant improvement over existing methods to determine phenolic metabolites circulating in blood and plasma samples, thus making blood sampling possible with the volunteer pricking their own finger, and the subsequent storage of the blood in the DBS cards prior to chromatographic analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Detection of bacteria and fungi in blood of patients with febrile neutropenia by real-time PCR with universal primers and probes.

    PubMed

    Teranishi, Hideto; Ohzono, Nanae; Inamura, Norikazu; Kato, Atsushi; Wakabayashi, Tokio; Akaike, Hiroto; Terada, Kihei; Ouchi, Kazunobu

    2015-03-01

    Febrile neutropenia is the main treatment-related cause of mortality in cancer patients. During June 2012 to April 2014, 97 blood culture samples were collected from patients receiving chemotherapy for hematological malignancy and cancer with febrile neutropenia episodes (FNEs). The samples were examined for the presence of bacteria and fungi using real-time PCR amplification and sequencing of 16S and 18S rRNA genes. Bacteria were identified in 20 of 97 samples (20.6%) by the real-time PCR assay and in 10 of 97 (10.3%) samples by blood culture. In 6 blood culture-positive samples, the real-time PCR assay detected the same type of bacteria. No fungi were detected by the real-time PCR assay or blood culture. During antibiotic therapy, all samples were negative by blood culture, but the real-time PCR assay yielded a positive result in 2 cases of 2 (100%). The bacterial DNA copy number was not well correlated with the serum C-reactive protein titer of patients with FNEs. We conclude that a real-time PCR assay could provide better detection of causative microbes' in a shorter time, and with a smaller blood sample than blood culture. Using a real-time PCR assay in combination with blood culture could improve microbiological documentation of FNEs. Copyright © 2014 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  1. Evaluation of the Effects of Various Sound Pressure Levels on the Level of Serum Aldosterone Concentration in Rats

    PubMed Central

    Nassiri, Parvin; Zare, Sajad; Monazzam, Mohammad R.; Pourbakht, Akram; Azam, Kamal; Golmohammadi, Taghi

    2017-01-01

    Introduction: Noise exposure may have anatomical, nonauditory, and auditory influences. Considering nonauditory impacts, noise exposure can cause alterations in the automatic nervous system, including increased pulse rates, heightened blood pressure, and abnormal secretion of hormones. The present study aimed at examining the effect of various sound pressure levels (SPLs) on the serum aldosterone level among rats. Materials and Methods: A total of 45 adult male rats with an age range of 3 to 4 months and a weight of 200 ± 50 g were randomly divided into 15 groups of three. Three groups were considered as the control groups and the rest (i.e., 12 groups) as the case groups. Rats of the case groups were exposed to SPLs of 85, 95, and 105 dBA. White noise was used as the noise to which the rats were exposed. To measure the level of rats’ serum aldosterone, 3 mL of each rat’s sample blood was directly taken from the heart of anesthetized animals by using syringes. The taken blood samples were put in labeled test tubes that contained anticoagulant Ethylenediaminetetraacetic acid. In the laboratory, the level of aldosterone was assessed through Enzyme-linked immunosorbent assay protocol. The collected data were analyzed by the use of Statistical Package for Social Sciences (SPSS) version 18. Results: The results revealed that there was no significant change in the level of rats’ serum aldosterone as a result of exposure to SPLs of 65, 85, and 95 dBA. However, the level of serum aldosterone experienced a remarkable increase after exposure to the SPL of 105 dBA (P < 0.001). Thus, the SPL had a significant impact on the serum aldosterone level (P < 0.001). In contrast, the exposure time and the level of potassium in the used water did not have any measurable influence on the level of serum aldosterone (P = 0.25 and 0.39). Conclusion: The findings of this study demonstrated that serum aldosterone can be used as a biomarker in the face of sound exposure. PMID:28816207

  2. Automated potentiometric electrolyte analysis system. [for use in weightlessness

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The feasibility is demonstrated of utilizing chemical sensing electrode technology as the basis for an automatically-controlled system for blood gas and electrolyte analyses under weightlessness conditions. The specific measurements required were pH, pCO2, sodium, chloride, potassium ions, and ionized calcium. The general electrode theory, and ion activity measurements are described along with the fluid transport package, electronics unit, and controller for the automated potentiometric analysis system.

  3. Biomedical Equipment Maintenance Career Ladder, AFSC 918X0

    DTIC Science & Technology

    1989-01-01

    incubators, fetal heart monitors, and vital sign monitors. In comparison, higher percent- ages of the 5-skill level group maintain x-ray equipment...ECG) Monitors 87 Hypo/Hyperthermia Units 85 Incubators 85 Audiometer Systems 84 Blood Pressure Monitors, Automatic 81 Fetal Heart Monitors 80 X-Ray...01462 VERIFY CALIBRATION OF FETAL HEART MONITORS 100 G281 PERFORM OPERATIONAL INSPECTIONS OF VITAL SIGN MONITORS 100 01435 PERFORM PREVENTIVE

  4. Automatic detection of micro-aneurysms in retinal images based on curvelet transform and morphological operations

    NASA Astrophysics Data System (ADS)

    Mohammad Alipour, Shirin Hajeb; Rabbani, Hossein

    2013-09-01

    Diabetic retinopathy (DR) is one of the major complications of diabetes that changes the blood vessels of the retina and distorts patient vision that finally in high stages can lead to blindness. Micro-aneurysms (MAs) are one of the first pathologies associated with DR. The number and the location of MAs are very important in grading of DR. Early diagnosis of micro-aneurysms (MAs) can reduce the incidence of blindness. As MAs are tiny area of blood protruding from vessels in the retina and their size is about 25 to 100 microns, automatic detection of these tiny lesions is still challenging. MAs occurring in the macula can lead to visual loss. Also the position of a lesion such as MAs relative to the macula is a useful feature for analysis and classification of different stages of DR. Because MAs are more distinguishable in fundus fluorescin angiography (FFA) compared to color fundus images, we introduce a new method based on curvelet transform and morphological operations for MAs detection in FFA images. As vessels and MAs are the bright parts of FFA image, firstly extracted vessels by curvelet transform are removed from image. Then morphological operations are applied on resulted image for detecting MAs.

  5. Automated region selection for analysis of dynamic cardiac SPECT data

    NASA Astrophysics Data System (ADS)

    Di Bella, E. V. R.; Gullberg, G. T.; Barclay, A. B.; Eisner, R. L.

    1997-06-01

    Dynamic cardiac SPECT using Tc-99m labeled teboroxime can provide kinetic parameters (washin, washout) indicative of myocardial blood flow. A time-consuming and subjective step of the data analysis is drawing regions of interest to delineate blood pool and myocardial tissue regions. The time-activity curves of the regions are then used to estimate local kinetic parameters. In this work, the appropriate regions are found automatically, in a manner similar to that used for calculating maximum count circumferential profiles in conventional static cardiac studies. The drawbacks to applying standard static circumferential profile methods are the high noise level and high liver uptake common in dynamic teboroxime studies. Searching along each ray for maxima to locate the myocardium does not typically provide useful information. Here we propose an iterative scheme in which constraints are imposed on the radii searched along each ray. The constraints are based on the shape of the time-activity curves of the circumferential profile members and on an assumption that the short axis slices are approximately circular. The constraints eliminate outliers and help to reduce the effects of noise and liver activity. Kinetic parameter estimates from the automatically generated regions were comparable to estimates from manually selected regions in dynamic canine teboroxime studies.

  6. ART-ML - a novel XML format for the biological procedures modeling and the representation of blood flow simulation.

    PubMed

    Karvounis, E C; Tsakanikas, V D; Fotiou, E; Fotiadis, D I

    2010-01-01

    The paper proposes a novel Extensible Markup Language (XML) based format called ART-ML that aims at supporting the interoperability and the reuse of models of blood flow, mass transport and plaque formation, exported by ARTool. ARTool is a platform for the automatic processing of various image modalities of coronary and carotid arteries. The images and their content are fused to develop morphological models of the arteries in easy to handle 3D representations. The platform incorporates efficient algorithms which are able to perform blood flow simulation. In addition atherosclerotic plaque development is estimated taking into account morphological, flow and genetic factors. ART-ML provides a XML format that enables the representation and management of embedded models within the ARTool platform and the storage and interchange of well-defined information. This approach influences in the model creation, model exchange, model reuse and result evaluation.

  7. An artificial pancreas provided a novel model of blood glucose level variability in beagles.

    PubMed

    Munekage, Masaya; Yatabe, Tomoaki; Kitagawa, Hiroyuki; Takezaki, Yuka; Tamura, Takahiko; Namikawa, Tsutomu; Hanazaki, Kazuhiro

    2015-12-01

    Although the effects on prognosis of blood glucose level variability have gained increasing attention, it is unclear whether blood glucose level variability itself or the manifestation of pathological conditions that worsen prognosis. Then, previous reports have not been published on variability models of perioperative blood glucose levels. The aim of this study is to establish a novel variability model of blood glucose concentration using an artificial pancreas. We maintained six healthy, male beagles. After anesthesia induction, a 20-G venous catheter was inserted in the right femoral vein and an artificial pancreas (STG-22, Nikkiso Co. Ltd., Tokyo, Japan) was connected for continuous blood glucose monitoring and glucose management. After achieving muscle relaxation, total pancreatectomy was performed. After 1 h of stabilization, automatic blood glucose control was initiated using the artificial pancreas. Blood glucose level varied for 8 h, alternating between the target blood glucose values of 170 and 70 mg/dL. Eight hours later, the experiment was concluded. Total pancreatectomy was performed for 62 ± 13 min. Blood glucose swings were achieved 9.8 ± 2.3 times. The average blood glucose level was 128.1 ± 5.1 mg/dL with an SD of 44.6 ± 3.9 mg/dL. The potassium levels after stabilization and at the end of the experiment were 3.5 ± 0.3 and 3.1 ± 0.5 mmol/L, respectively. In conclusion, the results of the present study demonstrated that an artificial pancreas contributed to the establishment of a novel variability model of blood glucose levels in beagles.

  8. Unsupervised Learning —A Novel Clustering Method for Rolling Bearing Faults Identification

    NASA Astrophysics Data System (ADS)

    Kai, Li; Bo, Luo; Tao, Ma; Xuefeng, Yang; Guangming, Wang

    2017-12-01

    To promptly process the massive fault data and automatically provide accurate diagnosis results, numerous studies have been conducted on intelligent fault diagnosis of rolling bearing. Among these studies, such as artificial neural networks, support vector machines, decision trees and other supervised learning methods are used commonly. These methods can detect the failure of rolling bearing effectively, but to achieve better detection results, it often requires a lot of training samples. Based on above, a novel clustering method is proposed in this paper. This novel method is able to find the correct number of clusters automatically the effectiveness of the proposed method is validated using datasets from rolling element bearings. The diagnosis results show that the proposed method can accurately detect the fault types of small samples. Meanwhile, the diagnosis results are also relative high accuracy even for massive samples.

  9. Non-terminal blood sampling techniques in guinea pigs.

    PubMed

    Birck, Malene M; Tveden-Nyborg, Pernille; Lindblad, Maiken M; Lykkesfeldt, Jens

    2014-10-11

    Guinea pigs possess several biological similarities to humans and are validated experimental animal models(1-3). However, the use of guinea pigs currently represents a relatively narrow area of research and descriptive data on specific methodology is correspondingly scarce. The anatomical features of guinea pigs are slightly different from other rodent models, hence modulation of sampling techniques to accommodate for species-specific differences, e.g., compared to mice and rats, are necessary to obtain sufficient and high quality samples. As both long and short term in vivo studies often require repeated blood sampling the choice of technique should be well considered in order to reduce stress and discomfort in the animals but also to ensure survival as well as compliance with requirements of sample size and accessibility. Venous blood samples can be obtained at a number of sites in guinea pigs e.g., the saphenous and jugular veins, each technique containing both advantages and disadvantages(4,5). Here, we present four different blood sampling techniques for either conscious or anaesthetized guinea pigs. The procedures are all non-terminal procedures provided that sample volumes and number of samples do not exceed guidelines for blood collection in laboratory animals(6). All the described methods have been thoroughly tested and applied for repeated in vivo blood sampling in studies within our research facility.

  10. The counting of native blood cells by digital microscopy

    NASA Astrophysics Data System (ADS)

    Torbin, S. O.; Doubrovski, V. A.; Zabenkov, I. V.; Tsareva, O. E.

    2017-03-01

    An algorithm for photographic images processing of blood samples in its native state was developed to determine the concentration of erythrocytes, leukocytes and platelets without individual separate preparation of cells' samples. Special "photo templates" were suggested to use in order to identify red blood cells. The effect of "highlighting" of leukocytes, which was found by authors, was used to increase the accuracy of this type of cells counting. Finally to raise the resolution of platelets from leukocytes the areas of their photo images were used, but not their sizes. It is shown that the accuracy of cells counting for native blood samples may be comparable with the accuracy of similar studies for smears. At the same time the proposed native blood analysis simplifies greatly the procedure of sample preparation in comparison to smear, permits to move from the detection of blood cells ratio to the determination of their concentrations in the sample.

  11. Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements.

    PubMed

    Pierin, Angela M G; Alavarce, Débora C; Gusmão, Josiane L; Halpern, Alfredo; Mion, Décio

    2004-06-01

    It is well known that blood pressure measurement with a standard 12-13 cm wide cuff is erroneous for large arms. To compare arm blood pressure measurements with an appropriate cuff and forearm blood pressure measurements (BPM) with a standard cuff, and both measurements by the Photopletismography (Finapres) method. One hundred and twenty-nine obese patients were studied (body mass index=40+/-7 kg/m2). The patients had three arm BPM taken by an automatic oscillometric device using an appropriate cuff and three forearm BPM with a standard cuff in the sitting position after a five-minute rest. Data were analysed by the analysis of variance. The correction values were obtained by the linear regression test. Systolic and diastolic arm BPM with an appropriate cuff were significantly lower (p<0.05) than forearm BPM with a standard cuff. The measurements obtained by Finapres were significantly lower (p<0.05) than those found for forearm systolic and diastolic blood pressures and upper arm diastolic blood pressure. The equation to correct BPM in forearm in obese patients with arm circumference between 32-44 cm was: systolic BPM=33.2+/-0.68 x systolic forearm BPM, and diastolic BPM=25.2+0.59 x forearm diastolic BPM. This study showed that forearm blood pressure measurement overestimates the values of arm blood pressure measurement. In addition, it is possible to correct forearm BPM with an equation.

  12. Analysis of Hemoglobin A1c from Dried Blood Spot Samples with the Tina-quant® II Immunoturbidimetric Method

    PubMed Central

    Jones, Trevor G.; Warber, Kimbrough D.; Roberts, Billy D.

    2010-01-01

    Background Hemoglobin A1c (HbA1c) has been endorsed as a tool for the diagnosis of diabetes. This test requires instrumentation that may not be available in underdeveloped areas. Dried blood spot (DBS) samples collected by finger stick procedures offer a mechanism to transport samples to laboratories that do measure HbA1c. Methods Whole blood (ethylenediaminetetraacetic acid) was applied to Ahlstrom 226 filter paper. These DBS samples were compared to whole blood samples using the Roche Tina-quant® II immunoturbidometric assay. Hemoglobin A1c stability on DBS was assessed at three temperatures—4, 25, and 40°C—for up to 9 days. A 44-day study was also done for DBS at 20–25°C. Results The Tina-quant® II DBS method showed excellent agreement with whole blood HbA1c results (r2 = 0.99) with a slight positive mean bias of 0.08 ± 0.04% HbA1c (95% confidence interval). The variation in HbA1c on DBS samples subjected to different temperatures and times did not exceed 5.6%. Conclusions Dried blood spot samples represent an alternative to whole blood for HbA1c by measurement when transporting whole blood is not feasible. PMID:20307383

  13. Preanalytical blood sample workup for cell-free DNA analysis using Droplet Digital PCR for future molecular cancer diagnostics.

    PubMed

    van Ginkel, Joost H; van den Broek, Daan A; van Kuik, Joyce; Linders, Dorothé; de Weger, Roel; Willems, Stefan M; Huibers, Manon M H

    2017-10-01

    In current molecular cancer diagnostics, using blood samples of cancer patients for the detection of genetic alterations in plasma (cell-free) circulating tumor DNA (ctDNA) is an emerging practice. Since ctDNA levels in blood are low, highly sensitive Droplet Digital PCR (ddPCR) can be used for detecting rare mutational targets. In order to perform ddPCR on blood samples, a standardized procedure for processing and analyzing blood samples is necessary to facilitate implementation into clinical practice. Therefore, we assessed the technical sample workup procedure for ddPCR on blood plasma samples. Blood samples from healthy individuals, as well as lung cancer patients were analyzed. We compared different methods and protocols for sample collection, storage, centrifugation, isolation, and quantification. Cell-free DNA (cfDNA) concentrations of several wild-type targets and BRAF and EGFR-mutant ctDNA concentrations quantified by ddPCR were primary outcome measurements. Highest cfDNA concentrations were measured in blood collected in serum tubes. No significant differences in cfDNA concentrations were detected between various time points of up to 24 h until centrifugation. Highest cfDNA concentrations were detected after DNA isolation with the Quick cfDNA Serum & Plasma Kit, while plasma isolation using the QIAamp Circulating Nucleic Acid Kit yielded the most consistent results. DdPCR results on cfDNA are highly dependent on multiple factors during preanalytical sample workup, which need to be addressed during the development of this diagnostic tool for cancer diagnostics in the future. © 2017 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  14. Quasi-static acoustic tweezing thromboelastometry.

    PubMed

    Holt, R G; Luo, D; Gruver, N; Khismatullin, D B

    2017-07-01

    Essentials Blood coagulation measurement during contact with an artificial surface leads to unreliable data. Acoustic tweezing thromboelastometry is a novel non-contact method for coagulation monitoring. This method detects differences in the blood coagulation state within 10 min. Coagulation data were obtained using a much smaller sample volume (4 μL) than currently used. Background Thromboelastography is widely used as a tool to assess the coagulation status of critical care patients. It allows observation of changes in material properties of whole blood, beginning with early stages of clot formation and ending with clot lysis. However, the contact activation of the coagulation cascade at surfaces of thromboelastographic systems leads to inherent variability and unreliability in predicting bleeding or thrombosis risks. Objectives To develop acoustic tweezing thromboelastometry as a non-contact method for perioperative assessment of blood coagulation. Methods Acoustic tweezing is used to levitate microliter drops of biopolymer and human blood samples. By quasi-statically changing the acoustic pressure we control the sample drop location and deformation. Sample size, deformation and location are determined by digital imaging at each pressure. Results Simple Newtonian liquid solutions maintain a constant, reversible location vs. deformation curve. In contrast, the location/deformation curves for gelatin, alginate, whole blood and blood plasma uniquely change as the samples solidify. Increasing elasticity causes the sample to deform less, leading to steeper stress/strain curves. By extracting a linear regime slope, we show that whole blood or blood plasma exhibits a unique slope profile as it begins to clot. By exposing blood samples to pro- or antithrombotic agents, the slope profile changes, allowing detection of hyper- or hypocoagulable states. Conclusions We demonstrate that quasi-static acoustic tweezing can yield information about clotting onset, maturation and strength. The advantages of small sample size, non-contact and rapid measurement make this technique desirable for real-time monitoring of blood coagulation. © 2017 International Society on Thrombosis and Haemostasis.

  15. Levels of organochlorine pesticides in the blood of people living in areas of intensive pesticide use in Sudan.

    PubMed

    Elbashir, Ahmed B; Abdelbagi, Azhari O; Hammad, Ahmed M A; Elzorgani, Gafar A; Laing, Mark D

    2015-03-01

    Ninety-six human blood samples were collected from six locations that represent areas of intensive pesticide use in Sudan, which included irrigated cotton schemes (Wad Medani, Hasaheesa, Elmanagil, and Elfaw) and sugarcane schemes (Kenana and Gunaid). Blood samples were analyzed for organochlorine pesticide residues by gas liquid chromatography (GLC) equipped with an electron capture detector (ECD). Residues of p,p'-dichlorodiphenyldichloroethylene (DDE), heptachlor epoxide, γ-HCH, and dieldrin were detected in blood from all locations surveyed. Aldrin was not detected in any of the samples analyzed, probably due to its conversion to dieldrin. The levels of total organochlorine burden detected were higher in the blood from people in the irrigated cotton schemes (mean 261 ng ml(-1), range 38-641 ng ml(-1)) than in the blood of people from the irrigated sugarcane schemes (mean 204 ng ml(-1), range 59-365 ng ml(-1)). The highest levels of heptachlor epoxide (170 ng ml(-1)) and γ-HCH (92 ng ml(-1)) were observed in blood samples from Hasaheesa, while the highest levels of DDE (618 ng ml(-1)) and dieldrin (82 ng ml(-1)) were observed in blood samples from Wad Medani and Kenana, respectively. The organochlorine levels in blood samples seemed to decrease with increasing distance from the old irrigated cotton schemes (Wad Medani, Hasaheesa, and Elmanagil) where the heavy application of these pesticides took place historically.

  16. Distribution of Dengue Virus Types 1 and 4 in Blood Components from Infected Blood Donors from Puerto Rico

    PubMed Central

    Añez, Germán; Heisey, Daniel A. R.; Chancey, Caren; Fares, Rafaelle C. G.; Espina, Luz M.; Souza, Kátia P. R.; Teixeira-Carvalho, Andréa; Krysztof, David E.; Foster, Gregory A.; Stramer, Susan L.; Rios, Maria

    2016-01-01

    Background Dengue is a mosquito-borne viral disease caused by the four dengue viruses (DENV-1 to 4) that can also be transmitted by blood transfusion and organ transplantation. The distribution of DENV in the components of blood from infected donors is poorly understood. Methods We used an in-house TaqMan qRT-PCR assay to test residual samples of plasma, cellular components of whole blood (CCWB), serum and clot specimens from the same collection from blood donors who were DENV-RNA-reactive in a parallel blood safety study. To assess whether DENV RNA detected by TaqMan was associated with infectious virus, DENV infectivity in available samples was determined by culture in mosquito cells. Results DENV RNA was detected by TaqMan in all tested blood components, albeit more consistently in the cellular components; 78.8% of CCWB, 73.3% of clots, 86.7% of sera and 41.8% of plasma samples. DENV-1 was detected in 48 plasma and 97 CCWB samples while DENV-4 was detected in 21 plasma and 31 CCWB samples. In mosquito cell cultures, 29/111 (26.1%) plasma and 32/97 (32.7%) CCWB samples were infectious. A subset of samples from 29 donors was separately analyzed to compare DENV viral loads in the available blood components. DENV viral loads did not differ significantly between components and ranged from 3–8 log10 PCR-detectable units/ml. Conclusions DENV was present in all tested components from most donors, and viral RNA was not preferentially distributed in any of the tested components. Infectious DENV was also present in similar proportions in cultured plasma, clot and CCWB samples, indicating that these components may serve as a resource when sample sizes are limited. However, these results suggest that the sensitivity of the nucleic acid tests (NAT) for these viruses would not be improved by testing whole blood or components other than plasma. PMID:26871560

  17. Distribution of Dengue Virus Types 1 and 4 in Blood Components from Infected Blood Donors from Puerto Rico

    DOE PAGES

    Anez, German; Heisey, Daniel A. R.; Chancey, Caren; ...

    2016-02-12

    Dengue is a mosquito-borne viral disease caused by the four dengue viruses (DENV-1 to 4) that can also be transmitted by blood transfusion and organ transplantation. The distribution of DENV in the components of blood from infected donors is poorly understood. Here, we used an in-house TaqMan qRT-PCR assay to test residual samples of plasma, cellular components of whole blood (CCWB), serum and clot specimens from the same collection from blood donors who were DENV-RNA-reactive in a parallel blood safety study. To assess whether DENV RNA detected by TaqMan was associated with infectious virus, DENV infectivity in available samples wasmore » determined by culture in mosquito cells. As a result, DENV RNA was detected by TaqMan in all tested blood components, albeit more consistently in the cellular components; 78.8% of CCWB, 73.3% of clots, 86.7% of sera and 41.8% of plasma samples. DENV-1 was detected in 48 plasma and 97 CCWB samples while DENV-4 was detected in 21 plasma and 31 CCWB samples. In mosquito cell cultures, 29/111 (26.1%) plasma and 32/97 (32.7%) CCWB samples were infectious. A subset of samples from 29 donors was separately analyzed to compare DENV viral loads in the available blood components. DENV viral loads did not differ significantly between components and ranged from 3–8 log 10 PCR-detectable units/ml. In conclusion, DENV was present in all tested components from most donors, and viral RNA was not preferentially distributed in any of the tested components. Infectious DENV was also present in similar proportions in cultured plasma, clot and CCWB samples, indicating that these components may serve as a resource when sample sizes are limited. However, these results suggest that the sensitivity of the nucleic acid tests (NAT) for these viruses would not be improved by testing whole blood or components other than plasma.« less

  18. Distribution of Dengue Virus Types 1 and 4 in Blood Components from Infected Blood Donors from Puerto Rico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anez, German; Heisey, Daniel A. R.; Chancey, Caren

    Dengue is a mosquito-borne viral disease caused by the four dengue viruses (DENV-1 to 4) that can also be transmitted by blood transfusion and organ transplantation. The distribution of DENV in the components of blood from infected donors is poorly understood. Here, we used an in-house TaqMan qRT-PCR assay to test residual samples of plasma, cellular components of whole blood (CCWB), serum and clot specimens from the same collection from blood donors who were DENV-RNA-reactive in a parallel blood safety study. To assess whether DENV RNA detected by TaqMan was associated with infectious virus, DENV infectivity in available samples wasmore » determined by culture in mosquito cells. As a result, DENV RNA was detected by TaqMan in all tested blood components, albeit more consistently in the cellular components; 78.8% of CCWB, 73.3% of clots, 86.7% of sera and 41.8% of plasma samples. DENV-1 was detected in 48 plasma and 97 CCWB samples while DENV-4 was detected in 21 plasma and 31 CCWB samples. In mosquito cell cultures, 29/111 (26.1%) plasma and 32/97 (32.7%) CCWB samples were infectious. A subset of samples from 29 donors was separately analyzed to compare DENV viral loads in the available blood components. DENV viral loads did not differ significantly between components and ranged from 3–8 log 10 PCR-detectable units/ml. In conclusion, DENV was present in all tested components from most donors, and viral RNA was not preferentially distributed in any of the tested components. Infectious DENV was also present in similar proportions in cultured plasma, clot and CCWB samples, indicating that these components may serve as a resource when sample sizes are limited. However, these results suggest that the sensitivity of the nucleic acid tests (NAT) for these viruses would not be improved by testing whole blood or components other than plasma.« less

  19. Use of Dried Capillary Blood Sampling for Islet Autoantibody Screening in Relatives: A Feasibility Study.

    PubMed

    Bingley, Polly J; Rafkin, Lisa E; Matheson, Della; Steck, Andrea K; Yu, Liping; Henderson, Courtney; Beam, Craig A; Boulware, David C

    2015-12-01

    Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot-based screening to identify islet autoantibody-positive relatives potentially eligible for inclusion in prevention trials. Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies.

  20. Use of self-collected capillary blood samples for islet autoantibody screening in relatives: a feasibility and acceptability study.

    PubMed

    Liu, Y; Rafkin, L E; Matheson, D; Henderson, C; Boulware, D; Besser, R E J; Ferrara, C; Yu, L; Steck, A K; Bingley, P J

    2017-07-01

    To evaluate the feasibility of using self-collected capillary blood samples for islet autoantibody testing to identify risk in relatives of people with Type 1 diabetes. Participants were recruited via the observational TrialNet Pathway to Prevention study, which screens and monitors relatives of people with Type 1 diabetes for islet autoantibodies. Relatives were sent kits for capillary blood collection, with written instructions, an online instructional video link and a questionnaire. Sera from capillary blood samples were tested for autoantibodies to glutamic acid decarboxylase, islet antigen-2, insulin and zinc transporter 8. 'Successful' sample collection was defined as obtaining sufficient volume and quality to provide definitive autoantibody results, including confirmation of positive results by repeat assay. In 240 relatives who returned samples, the median (range) age was 15.5 (1-49) years and 51% were male. Of these samples, 98% were sufficient for glutamic acid decarboxylase, islet antigen-2 and zinc transporter 8 autoantibody testing and 84% for insulin autoantibody testing and complete autoantibody screen. The upper 90% confidence bound for unsuccessful collection was 4.4% for glutamic acid decarboxylase, islet antigen-2 and/or zinc transporter 8 autoantibody assays, and 19.3% for insulin autoantibodies. Despite 43% of 220 questionnaire respondents finding capillary blood collection uncomfortable or painful, 82% preferred home self-collection of capillary blood samples compared with outpatient venepuncture (90% of those aged <8 years, 83% of those aged 9-18 years and 73% of those aged >18 years). The perceived difficulty of collecting capillary blood samples did not affect success rate. Self-collected capillary blood sampling offers a feasible alternative to venous sampling, with the potential to facilitate autoantibody screening for Type 1 diabetes risk. © 2017 Diabetes UK.

  1. Comparison of haematology, coagulation and clinical chemistry parameters in blood samples from the sublingual vein and vena cava in Sprague-Dawley rats.

    PubMed

    Seibel, J; Bodié, K; Weber, S; Bury, D; Kron, M; Blaich, G

    2010-10-01

    The investigation of clinical pathology parameters (haematology, clinical chemistry and coagulation) is an important part of the preclinical evaluation of drug safety. However, the blood sampling method employed should avoid or minimize stress and injury in laboratory animals. In the present study, we compared the clinical pathology results from blood samples collected terminally from the vena cava (VC) immediately before necropsy with samples taken from the sublingual vein (VS) also prior to necropsy in order to determine whether the sampling method has an influence on clinical pathology parameters. Forty-six 12-week-old male Sprague-Dawley rats were assigned to two groups (VC or VS; n = 23 each). All rats were anaesthetized with isoflurane prior to sampling. In the VC group, blood was withdrawn from the inferior VC. For VS sampling, the tongue was gently pulled out and the VS was punctured. The haematology, coagulation and clinical chemistry parameters were compared. Equivalence was established for 13 parameters, such as mean corpuscular volume, white blood cells and calcium. No equivalence was found for the remaining 26 parameters, although they were considered to be similar when compared with the historical data and normal ranges. The most conspicuous finding was that activated prothrombin time was 30.3% less in blood taken from the VC (16.6 ± 0.89 s) than that in the VS samples (23.8 ± 1.58 s). Summing up, blood sampling from the inferior VC prior to necropsy appears to be a suitable and reliable method for terminal blood sampling that reduces stress and injury to laboratory rats in preclinical drug safety studies.

  2. Screening for intermediate and severe forms of thalassaemia in discarded red blood cells: optimization and feasibility.

    PubMed

    George, Elizabeth; Lai, Mei I; Teh, Lai Kuan; Ramasamy, Rajesh; Goh, Ern Huei; Asokan, Kamalan; Tan, J A M A; Vasudevan, Maithili; Low, Sharon

    2011-12-01

    Detection and quantification of Hb subtypes of human blood is integral to presumptive identification of thalassaemias. It has been used in neonatal screening of thalassaemia and Hb variants. The use of discarded red blood cells following processing of the cord blood for stem cells provides readily available diagnostic material for thalassaemia screening. In this study, we determined the range of Hb subtypes in 195 consecutive cord blood samples collected for cord blood banking. The 'cord blood samples' analysed were those of the remaining red blood cells after the cord blood was processed for stem cell storage. Quantification of Hb subtypes by high performance liquid chromatography (HPLC) was done on BioRad Variant II Hb testing system. Only 73 (36.5%) of the samples could be analyzed neat without dilution. With a 1:300 dilution with wash solution the acceptable area as recommended by the manufacturer for reading of a C-gram within the 1 to 3 million ranges were achieved in all. Eighteen (9%) 12 showed classical Hb Barts (y4) prerun peaks were confirmed by Sebia Hydrasys automated Hb gel electrophoresis and quantified by Sebia Capillarys 2 capillary electrophoresis. Only 1 (0.5%) was presumptively identified with HbH disease. Due to the limited number of samples no beta-thalassaemia major, Hb E beta-thalassaemia and Hb Barts hydrops fetalis were found. The HPLC assay was possible at a cost US$ 5 per sample and a turnover time of 10 samples per hour without technical difficulties. This study reports an effective and valuable protocol for thalassaemia screening in red blood cells which would otherwise be discarded during cord blood processing. Cord blood with severe and intermediate forms of thalassaemia can be preselected and not stored.

  3. Development of a Korotkov sound processor for automatic identification of auscultatory events. I - Specification of preprocessing bandpass filters

    NASA Technical Reports Server (NTRS)

    Golden, D. P., Jr.; Wolthuis, R. A.; Hoffler, G. W.; Gowen, R. J.

    1974-01-01

    Frequency bands that best discriminate the Korotkov sounds at systole and at diastole from the sounds immediately preceding these events are defined. Korotkov sound data were recorded from five normotensive subjects during orthostatic stress (lower body negative pressure) and bicycle ergometry. A spectral analysis of the seven Korotkov sounds centered about the systolic and diastolic auscultatory events revealed that a maximum increase in amplitude at the systolic transition occurred in the 18-26-Hz band, while a maximum decrease in amplitude at the diastolic transition occurred in the 40-60-Hz band. These findings were remarkably consistent across subjects and test conditions. These passbands are included in the design specifications for an automatic blood pressure measuring system used in conjuction with medical experiments during NASA's Skylab program.

  4. A method for estimating radioactive cesium concentrations in cattle blood using urine samples.

    PubMed

    Sato, Itaru; Yamagishi, Ryoma; Sasaki, Jun; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Okada, Keiji

    2017-12-01

    In the region contaminated by the Fukushima nuclear accident, radioactive contamination of live cattle should be checked before slaughter. In this study, we establish a precise method for estimating radioactive cesium concentrations in cattle blood using urine samples. Blood and urine samples were collected from a total of 71 cattle on two farms in the 'difficult-to-return zone'. Urine 137 Cs, specific gravity, electrical conductivity, pH, sodium, potassium, calcium, and creatinine were measured and various estimation methods for blood 137 Cs were tested. The average error rate of the estimation was 54.2% without correction. Correcting for urine creatinine, specific gravity, electrical conductivity, or potassium improved the precision of the estimation. Correcting for specific gravity using the following formula gave the most precise estimate (average error rate = 16.9%): [blood 137 Cs] = [urinary 137 Cs]/([specific gravity] - 1)/329. Urine samples are faster to measure than blood samples because urine can be obtained in larger quantities and has a higher 137 Cs concentration than blood. These advantages of urine and the estimation precision demonstrated in our study, indicate that estimation of blood 137 Cs using urine samples is a practical means of monitoring radioactive contamination in live cattle. © 2017 Japanese Society of Animal Science.

  5. Capillary whole blood testing by a new portable monitor. Comparison with standard determination of the international normalized ratio.

    PubMed

    de Miguel, Dunia; Burgaleta, Carmen; Reyes, Eduardo; Pascual, Teresa

    2003-07-01

    We evaluated a new portable monitor (AvoSure PT PRO, Menarini Diagnostics, Firenze, Italy) developed to test the prothrombin time in capillary blood and plasma by comparing it with the standard laboratory determination. We studied 62 patients receiving acenocoumarol therapy. The international normalized ratio (INR) in capillary blood was analyzed by 2 methods: AvoSure PT PRO and Thrombotrack Nycomed Analyzer (Axis-Shield, Dundee, Scotland). Parallel studies were performed in plasma samples by a reference method using the Behring Coagulation Timer (Behring Diagnostics, Marburg, Germany). Plasma samples also were tested with the AvoSure PT PRO. Correlation was good for INR values for capillary blood and plasma samples by AvoSure PT PRO and our reference method (R2 = 0.8596) and for capillary blood samples tested by the AvoSure PT PRO and Thrombotrack Nycomed Analyzer (R2 = 0.8875). The correlation for INR in capillary blood and plasma samples by AvoSure PT PRO was 0.6939 (P < .0004). Capillary blood determinations are rapid and effective for monitoring oral anticoagulation therapy and have a high correlation to plasma determinations. AvoSure PT PRO is accurate for controlling INR in plasma and capillary blood samples, may be used in outpatient clinics, and has advantages over previous portable monitors.

  6. Novel Automatic Electrochemical-mechanical Polishing (ECMP) of Metals for Scanning Electron Microscopy (Postprint)

    DTIC Science & Technology

    2010-03-23

    Micron 41 (2010) 615–621 619 Fig. 4 . XPS binding energy (eV) versus sputtering time (s) results for the Ti 2p peaks for the titanium samples: (a...improved the IQ values. 4 . Conclusions The electrochemical–mechanical polishing system (ECMP) removed material from titanium and nickel alloys at a...March 2014 4 . TITLE AND SUBTITLE NOVEL AUTOMATIC ELECTROCHEMICAL-MECHANICAL POLISHING (ECMP) OF METALS FOR SCANNING ELECTRON MICROSCOPY

  7. Blood vessel segmentation algorithms - Review of methods, datasets and evaluation metrics.

    PubMed

    Moccia, Sara; De Momi, Elena; El Hadji, Sara; Mattos, Leonardo S

    2018-05-01

    Blood vessel segmentation is a topic of high interest in medical image analysis since the analysis of vessels is crucial for diagnosis, treatment planning and execution, and evaluation of clinical outcomes in different fields, including laryngology, neurosurgery and ophthalmology. Automatic or semi-automatic vessel segmentation can support clinicians in performing these tasks. Different medical imaging techniques are currently used in clinical practice and an appropriate choice of the segmentation algorithm is mandatory to deal with the adopted imaging technique characteristics (e.g. resolution, noise and vessel contrast). This paper aims at reviewing the most recent and innovative blood vessel segmentation algorithms. Among the algorithms and approaches considered, we deeply investigated the most novel blood vessel segmentation including machine learning, deformable model, and tracking-based approaches. This paper analyzes more than 100 articles focused on blood vessel segmentation methods. For each analyzed approach, summary tables are presented reporting imaging technique used, anatomical region and performance measures employed. Benefits and disadvantages of each method are highlighted. Despite the constant progress and efforts addressed in the field, several issues still need to be overcome. A relevant limitation consists in the segmentation of pathological vessels. Unfortunately, not consistent research effort has been addressed to this issue yet. Research is needed since some of the main assumptions made for healthy vessels (such as linearity and circular cross-section) do not hold in pathological tissues, which on the other hand require new vessel model formulations. Moreover, image intensity drops, noise and low contrast still represent an important obstacle for the achievement of a high-quality enhancement. This is particularly true for optical imaging, where the image quality is usually lower in terms of noise and contrast with respect to magnetic resonance and computer tomography angiography. No single segmentation approach is suitable for all the different anatomical region or imaging modalities, thus the primary goal of this review was to provide an up to date source of information about the state of the art of the vessel segmentation algorithms so that the most suitable methods can be chosen according to the specific task. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Application of Magnetic Nanoparticles in Pretreatment Device for POPs Analysis in Water

    NASA Astrophysics Data System (ADS)

    Chu, Dongzhi; Kong, Xiangfeng; Wu, Bingwei; Fan, Pingping; Cao, Xuan; Zhang, Ting

    2018-01-01

    In order to reduce process time and labour force of POPs pretreatment, and solve the problem that extraction column was easily clogged, the paper proposed a new technology of extraction and enrichment which used magnetic nanoparticles. Automatic pretreatment system had automatic sampling unit, extraction enrichment unit and elution enrichment unit. The paper briefly introduced the preparation technology of magnetic nanoparticles, and detailly introduced the structure and control system of automatic pretreatment system. The result of magnetic nanoparticles mass recovery experiments showed that the system had POPs analysis preprocessing capability, and the recovery rate of magnetic nanoparticles were over 70%. In conclusion, the author proposed three points optimization recommendation.

  9. Automatic patient dose registry and clinical audit on line for mammography.

    PubMed

    Ten, J I; Vano, E; Sánchez, R; Fernandez-Soto, J M

    2015-07-01

    The use of automatic registry systems for patient dose in digital mammography allows clinical audit and patient dose analysis of the whole sample of individual mammography exposures while fulfilling the requirements of the European Directives and other international recommendations. Further parameters associated with radiation exposure (tube voltage, X-ray tube output and HVL values for different kVp and target/filter combinations, breast compression, etc.) should be periodically verified and used to evaluate patient doses. This study presents an experience in routine clinical practice for mammography using automatic systems. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Quantitative Analysis of Therapeutic Drugs in Dried Blood Spot Samples by Paper Spray Mass Spectrometry: An Avenue to Therapeutic Drug Monitoring

    NASA Astrophysics Data System (ADS)

    Manicke, Nicholas Edward; Abu-Rabie, Paul; Spooner, Neil; Ouyang, Zheng; Cooks, R. Graham

    2011-09-01

    A method is presented for the direct quantitative analysis of therapeutic drugs from dried blood spot samples by mass spectrometry. The method, paper spray mass spectrometry, generates gas phase ions directly from the blood card paper used to store dried blood samples without the need for complex sample preparation and separation; the entire time for preparation and analysis of blood samples is around 30 s. Limits of detection were investigated for a chemically diverse set of some 15 therapeutic drugs; hydrophobic and weakly basic drugs, such as sunitinib, citalopram, and verapamil, were found to be routinely detectable at approximately 1 ng/mL. Samples were prepared by addition of the drug to whole blood. Drug concentrations were measured quantitatively over several orders of magnitude, with accuracies within 10% of the expected value and relative standard deviation (RSD) of around 10% by prespotting an internal standard solution onto the paper prior to application of the blood sample. We have demonstrated that paper spray mass spectrometry can be used to quantitatively measure drug concentrations over the entire therapeutic range for a wide variety of drugs. The high quality analytical data obtained indicate that the technique may be a viable option for therapeutic drug monitoring.

  11. Exploiting automatic on-line renewable molecularly imprinted solid-phase extraction in lab-on-valve format as front end to liquid chromatography: application to the determination of riboflavin in foodstuffs.

    PubMed

    Oliveira, Hugo M; Segundo, Marcela A; Lima, José L F C; Miró, Manuel; Cerdà, Victor

    2010-05-01

    In the present work, it is proposed, for the first time, an on-line automatic renewable molecularly imprinted solid-phase extraction (MISPE) protocol for sample preparation prior to liquid chromatographic analysis. The automatic microscale procedure was based on the bead injection (BI) concept under the lab-on-valve (LOV) format, using a multisyringe burette as propulsion unit for handling solutions and suspensions. A high precision on handling the suspensions containing irregularly shaped molecularly imprinted polymer (MIP) particles was attained, enabling the use of commercial MIP as renewable sorbent. The features of the proposed BI-LOV manifold also allowed a strict control of the different steps within the extraction protocol, which are essential for promoting selective interactions in the cavities of the MIP. By using this on-line method, it was possible to extract and quantify riboflavin from different foodstuff samples in the range between 0.450 and 5.00 mg L(-1) after processing 1,000 microL of sample (infant milk, pig liver extract, and energy drink) without any prior treatment. For milk samples, LOD and LOQ values were 0.05 and 0.17 mg L(-1), respectively. The method was successfully applied to the analysis of two certified reference materials (NIST 1846 and BCR 487) with high precision (RSD < 5.5%). Considering the downscale and simplification of the sample preparation protocol and the simultaneous performance of extraction and chromatographic assays, a cost-effective and enhanced throughput (six determinations per hour) methodology for determination of riboflavin in foodstuff samples is deployed here.

  12. Simplified Pan-species Real-time PCR-based Detection of Plasmodium Spp. in Blood Smear.

    PubMed

    Hassanpour, Gholamreza; Mirhendi, Hossein; Mohebali, Mehdi; Raeisi, Ahmad; Zeraati, Hojjat; Keshavarz, Hossein

    2016-01-01

    We aimed to quicken and simplify the detection of Plasmodium in blood samples by developing and testing a pan- Plasmodium real-time PCR for accurate screening of individuals suspected of malaria. A single primer/probe set for pan-species Plasmodium -specific real time PCR targeting a conserved region of the small subunit 18S ribosomal DNA was designed and evaluated for rapid diagnosis and screening of malaria infections using dried blood smears. FTA cards were used for rapid and simple DNA extraction. The primers and probes showed a positive response with the DNA extracted from bloods infected with P. falciparum and P. vivax but not with DNA extracted from various smears from uninfected blood samples. Seven positive cases positive by both microscopy and nested PCR were found among 280 blood samples taken from in South and Southeast Iran. Five samples were identified as positive for P. vivax and two as positive for P. falciparum . All positive samples were positive by real-time PCR. Furthermore, all 38-blood samples positive by microscopy were positive by real-time PCR. No microscopy-negative samples were positive by real-time PCR. By using a simple FTA card for DNA extraction and by application of the real-time PCR developed in this study, sensitivity similar to nested-PCR and microscopy was achieved. This format simplifies the detection of Plasmodium in large numbers of samples.

  13. Vaccination and blood sampling acceptability during Ramadan fasting month: A cross-sectional study in Conakry, Guinea.

    PubMed

    Peiffer-Smadja, Nathan; Ouedraogo, Ramatou; D'Ortenzio, Eric; Cissé, Papa Ndiaga; Zeggani, Zahra; Beavogui, Abdoul Habib; Faye, Sylvain Landry; Le Marcis, Frédéric; Yazdanpanah, Yazdan; Nguyen, Vinh-Kim

    2017-05-02

    There are few data on the acceptability of vaccination or blood sampling during Ramadan fasting month in Muslim countries. This could impact vaccination campaigns, clinical trials or healthcare during Ramadan. Using a semi-structured questionnaire, we conducted a cross-sectional study on 201 practising Muslims and 10 religious leaders in Conakry, Guinea in the wake of the recent epidemic Ebola epidemic. Acceptability of vaccination and blood sampling during Ramadan were investigated as well as reasons for refusal. Vaccination was judged acceptable during Ramadan by 46% (93/201, 95% CI 0.40-0.53) of practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) of religious leaders (p=0.11). Blood sampling was judged acceptable during Ramadan by 54% (108/201, 95% CI 0.47-0.60) of practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) of religious leaders (p=0.19). The percentage of participants that judged both blood sampling and vaccination acceptable during Ramadan was 40% (81/201, 95% CI 0.34-0.47) for practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) for religious leaders (p=0.048). The most common reasons for refusal of vaccination or blood sampling were that nothing should enter or leave the body during Ramadan (43%), that adverse events could lead to breaking the fast (32%), that blood should not be seen during Ramadan (9%) and that the Quran explicitly forbids it (9%). Although most Muslims leaders and scientists consider that injections including immunization and blood sampling should be authorized during Ramadan, many Muslims in our study judged vaccination or blood sampling unacceptable when fasting. Widely available recommendations on healthcare during Ramadan would be useful to inform Muslims. Copyright © 2017. Published by Elsevier Ltd.

  14. New microfluidic-based sampling procedure for overcoming the hematocrit problem associated with dried blood spot analysis.

    PubMed

    Leuthold, Luc Alexis; Heudi, Olivier; Déglon, Julien; Raccuglia, Marc; Augsburger, Marc; Picard, Franck; Kretz, Olivier; Thomas, Aurélien

    2015-02-17

    Hematocrit (Hct) is one of the most critical issues associated with the bioanalytical methods used for dried blood spot (DBS) sample analysis. Because Hct determines the viscosity of blood, it may affect the spreading of blood onto the filter paper. Hence, accurate quantitative data can only be obtained if the size of the paper filter extracted contains a fixed blood volume. We describe for the first time a microfluidic-based sampling procedure to enable accurate blood volume collection on commercially available DBS cards. The system allows the collection of a controlled volume of blood (e.g., 5 or 10 μL) within several seconds. Reproducibility of the sampling volume was examined in vivo on capillary blood by quantifying caffeine and paraxanthine on 5 different extracted DBS spots at two different time points and in vitro with a test compound, Mavoglurant, on 10 different spots at two Hct levels. Entire spots were extracted. In addition, the accuracy and precision (n = 3) data for the Mavoglurant quantitation in blood with Hct levels between 26% and 62% were evaluated. The interspot precision data were below 9.0%, which was equivalent to that of a manually spotted volume with a pipet. No Hct effect was observed in the quantitative results obtained for Hct levels from 26% to 62%. These data indicate that our microfluidic-based sampling procedure is accurate and precise and that the analysis of Mavoglurant is not affected by the Hct values. This provides a simple procedure for DBS sampling with a fixed volume of capillary blood, which could eliminate the recurrent Hct issue linked to DBS sample analysis.

  15. The platelet count in EDTA-anticoagulated blood from patients with thrombocytopenia may be underestimated when measured in routine laboratories.

    PubMed

    Podda, Gian Marco; Pugliano, Mariateresa; Femia, Eti Alessandra; Mezzasoma, Anna Maria; Gresele, Paolo; Carpani, Giovanni; Cattaneo, Marco

    2012-07-01

    Spuriously low platelet counts (PCs) can be observed in normal blood samples anticoagulated with ethylenediamine tetra-acetic acid (EDTA)and, much less frequently, with citrate-tris-pyridossalphosphate (CPT),due to time-dependent in vitro platelet agglutination. Accuracy in PC determination is essential as PC is one of the parameters that usually guides treatment for thrombocytopenic patients. PCs of 93 thrombocy to penic patients were measured in EDTA- or CPT-anticoagulated blood samples immediately after sampling (t0) and 90 min (t90) after storage at room temperature. The presence of platelet agglutinates in blood samples was determined by examining blood smears using optical microscopy.PCs decreased at t90 with both anticoagulants. Platelet agglutinates were present at t90 in 27% of EDTA-samples vs. 2% of CPT-samples with decreased PCs (P < 0.001). Based on PCs in EDTA-samples, 15 patients (16%) shifted from a lower bleeding risk at t0 to a higher bleeding risk category at t90 (P 5 0.019), compared to 5 (5%) patients, based on PCs in CPT-samples. Therefore, time-dependent in vitro platelet agglutination in EDTA-blood samples may cause underestimation of PCs in thrombocytopenic patients, possibly leading to improper management.

  16. [Private umbilical cord blood banking does not reduce the number of samples for scientific stem cell research].

    PubMed

    Jacobs, V R; Niemeyer, M; Gottschalk, N; Schneider, K T; Kiechle, M

    2005-12-01

    Private umbilical cord blood (UCB) banking after delivery has increased over the last decade. For adult/somatic stem cell research UCB is an essential source of stem cells and researchers question if the number of UCB samples for research might be reduced by private banking. A survey among seven private blood banks in Germany and analysis and comparison of the number of UCB samples donated for research within the STEMMAT project with private blood banking were performed from 03/2003 to 06/2005 at the Frauenklinik (OB/GYN), Technical University Munich, Germany. Within 27.5 months 1,551 UCB samples were collected for research purposes; the effective recruitment rate was higher than expectations at an effective 66.2 %. Private UCB banking [n = 24] was distributed among three cord blood banks [n = 16, 6 and 4]. The rate of private blood banking was 0.99 % for all deliveries, thus reducing the effective rate for research purpose by only 1.5 %. Under the assumption of active and successful recruitment of scientific UCB samples, private blood banking does not significantly reduce this rate and therefore is a negligible rival in the competition for sufficient numbers of UCB samples for research.

  17. Evaluation of a novel dried blood spot collection device (HemaSpot™) to test blood samples collected from dogs for antibodies to Leishmania infantum.

    PubMed

    Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S

    2014-09-15

    Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test for antibodies in the ICT and compared to ICT results using thawed plasma (same initial source). Sensitivity and specificity of the ICT using DBS were determined by using ICT results from traditional blood collection samples for comparison. After 1 month, DBS samples showed 100% sensitivity and specificity when compared to ICT results on thawed plasma samples collected by traditional venipuncture. After six months storage at room temperature, DBS samples demonstrated 79% sensitivity and 100% specificity compared to traditional blood collection. Results from this study indicate that dried blood spot collection may be a useful tool for screening dogs for antibodies to L. infantum with the ICT assay. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Automatic transfer function generation for volume rendering of high-resolution x-ray 3D digital mammography images

    NASA Astrophysics Data System (ADS)

    Alyassin, Abdal M.

    2002-05-01

    3D Digital mammography (3DDM) is a new technology that provides high resolution X-ray breast tomographic data. Like any other tomographic medical imaging modalities, viewing a stack of tomographic images may require time especially if the images are of large matrix size. In addition, it may cause difficulty to conceptually construct 3D breast structures. Therefore, there is a need to readily visualize the data in 3D. However, one of the issues that hinder the usage of volume rendering (VR) is finding an automatic way to generate transfer functions that efficiently map the important diagnostic information in the data. We have developed a method that randomly samples the volume. Based on the mean and the standard deviation of these samples, the technique determines the lower limit and upper limit of a piecewise linear ramp transfer function. We have volume rendered several 3DDM data using this technique and compared visually the outcome with the result from a conventional automatic technique. The transfer function generated through the proposed technique provided superior VR images over the conventional technique. Furthermore, the improvement in the reproducibility of the transfer function correlated with the number of samples taken from the volume at the expense of the processing time.

  19. Affective decision-making moderates the effects of automatic associations on alcohol use among drug offenders.

    PubMed

    Cappelli, Christopher; Ames, Susan; Shono, Yusuke; Dust, Mark; Stacy, Alan

    2017-09-01

    This study used a dual-process model of cognition in order to investigate the possible influence of automatic and deliberative processes on lifetime alcohol use in a sample of drug offenders. The objective was to determine if automatic/implicit associations in memory can exert an influence over an individual's alcohol use and if decision-making ability could potentially modify the influence of these associations. 168 participants completed a battery of cognitive tests measuring implicit alcohol associations in memory (verb generation) as well as their affective decision-making ability (Iowa Gambling Task). Structural equation modeling procedures were used to test the relationship between implicit associations, decision-making, and lifetime alcohol use. Results revealed that among participants with lower levels of decision-making, implicit alcohol associations more strongly predicted higher lifetime alcohol use. These findings provide further support for the interaction between a specific decision function and its influence over automatic processes in regulating alcohol use behavior in a risky population. Understanding the interaction between automatic associations and decision processes may aid in developing more effective intervention components.

  20. Correlation between maternal and umbilical cord blood in pregnant women of Pokhara Valley: a cross sectional study.

    PubMed

    Timilsina, Sameer; Karki, Sirisa; Gautam, Aajeevan; Bhusal, Pujan; Paudel, Gita; Sharma, Deepak

    2018-03-21

    Complete blood count is one of the routinely advised blood investigation during pregnancy. It is also utilized as a diagnostic tool for neonatal anemia, sepsis and determining hemostatic status of the newborn. The present study aims at estimating the complete blood count of maternal and umbilical cord blood at the time of delivery and to establish its correlation. This cross sectional study included 114 mothers and their healthy neonates born through normal vaginal delivery. Complete blood count of umbilical cord blood and maternal blood was estimated using automatic hematology analyzer. The mean maternal and neonatal hemoglobin concentration was 11.14 ± 1.39 g/dL and 16.34 ± 2.01 g/dL respectively. A significant positive correlation was found between maternal and fetal hemoglobin concentration (p < 0.001 and Pearson R = 0.496). The correlation between maternal and fetal WBC, RBC and Platelet count was not statistically significant. A significant positive correlation was found between maternal and fetal MCV and MCH while PCV showed a non-significant positive correlation. There was moderately positive correlation between maternal and fetal hemoglobin, MCV and MCH. The cord blood hemoglobin was lower in babies born to anemic mothers. The decrease in hemoglobin followed the severity of anemia, however, the correlation did not exist in anemic mothers. It suggested that fetal hematological parameters are not reflective of maternal hemogram.

Top