Sample records for automatic choke device

  1. Magnetic resonance conditional paramagnetic choke for suppression of imaging artifacts during magnetic resonance imaging.

    PubMed

    Wu, Kevin J; Gregory, T Stan; Boland, Brian L; Zhao, Wujun; Cheng, Rui; Mao, Leidong; Tse, Zion Tsz Ho

    2018-06-01

    Higher risk patient populations require continuous physiological monitoring and, in some cases, connected life-support systems, during magnetic resonance imaging examinations. While recently there has been a shift toward wireless technology, some of the magnetic resonance imaging devices are still connected to the outside using cabling that could interfere with the magnetic resonance imaging's radio frequency during scanning, resulting in excessive heating. We developed a passive method for radio frequency suppression on cabling that may assist in making some of these devices magnetic resonance imaging compatible. A barrel-shaped strongly paramagnetic choke was developed to suppress induced radio frequency signals which are overlaid onto physiological monitoring leads during magnetic resonance imaging. It utilized a choke placed along the signal lines, with a gadolinium solution core. The choke's magnetic susceptibility was modeled, for a given geometric design, at increasing chelate concentration levels, and measured using a vibrating sample magnetometer. Radio frequency noise suppression versus frequency was quantified with network-analyzer measurements and tested using cabling placed in the magnetic resonance imaging scanner. Temperature-elevation and image-quality reduction due to the device were measured using American Society for Testing and Materials phantoms. Prototype chokes with gadolinium solution cores exhibited increasing magnetic susceptibility, and insertion loss (S21) also showed higher attenuation as gadolinium concentration increased. Image artifacts extending <4 mm from the choke were observed during magnetic resonance imaging, which agreed well with the predicted ∼3 mm artifact from the electrochemical machining simulation. An accompanying temperature increase of <1 °C was observed in the magnetic resonance imaging phantom trial. An effective paramagnetic choke for radio frequency suppression during magnetic resonance imaging was developed and its performance demonstrated.

  2. Photonic Choke-Joints for Dual-Polarization Waveguides

    NASA Technical Reports Server (NTRS)

    Wollack, Edward J.; U-yen, Kongpop; Chuss, David T.

    2010-01-01

    Photonic choke joint (PCJ) structures for dual-polarization waveguides have been investigated for use in device and component packaging. This interface enables the realization of a high performance non-contacting waveguide joint without degrading the in-band signal propagation properties. The choke properties of two tiling approaches, symmetric square Cartesian and octagonal quasi-crystal lattices of metallic posts, are explored and optimal PCJ design parameters are presented. For each of these schemes, the experimental results for structures with finite tilings demonstrate near ideal transmission and reflection performance over a full waveguide band.

  3. Reduction of resonant RF heating in intravascular catheters using coaxial chokes.

    PubMed

    Ladd, M E; Quick, H H

    2000-04-01

    The incorporation of RF coils into the tips of intravascular devices has been shown to enable the localization of catheters and guidewires under MR guidance. Furthermore, such coils can be used for endoluminal imaging. The long cable required to connect the coil with the scanner input inadvertently acts as a dipole antenna which picks up RF energy from the body coil during transmit. Currents are induced on the cable which can lead to localized heating of surrounding tissue. Cables of various lengths were measured to determine if a resonance in the heating as a function of cable length could be found. Coaxial chokes with a length of lambda/4 were added to coaxial cables to reduce the amplitude of the currents induced on the cable shield. A 0.7-mm diameter triaxial cable, small enough to fit into a standard intravascular device, was developed and measured both with and without a coaxial choke. It is demonstrated that resonant heating does occur and that it can be significantly reduced by avoiding a resonant length of cable and by including coaxial chokes on the cable.

  4. 40 CFR 610.21 - Device functional category and vehicle system effects.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... device's category will be based on: (1) Engineering principles governing operation of the device; (2... mechanical) All. Vapor Injectors All. Choke controls 1, 2, and 4. Air filters 1, 2, and 4. Fuel-air...

  5. 40 CFR 610.21 - Device functional category and vehicle system effects.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... device's category will be based on: (1) Engineering principles governing operation of the device; (2... mechanical) All. Vapor Injectors All. Choke controls 1, 2, and 4. Air filters 1, 2, and 4. Fuel-air...

  6. 40 CFR 610.21 - Device functional category and vehicle system effects.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... device's category will be based on: (1) Engineering principles governing operation of the device; (2... mechanical) All. Vapor Injectors All. Choke controls 1, 2, and 4. Air filters 1, 2, and 4. Fuel-air...

  7. 40 CFR 610.21 - Device functional category and vehicle system effects.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 1 Device categories Characteristics adversely affected Fuel-Air System Carburetors and fuel injection systems All. Air-fuel ratio modifiers (e.g., air bleeds) All. Atomization devices (acoustic and mechanical) All. Vapor Injectors All. Choke controls 1, 2, and 4. Air filters 1, 2, and 4. Fuel-air...

  8. 40 CFR 610.21 - Device functional category and vehicle system effects.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 1 Device categories Characteristics adversely affected Fuel-Air System Carburetors and fuel injection systems All. Air-fuel ratio modifiers (e.g., air bleeds) All. Atomization devices (acoustic and mechanical) All. Vapor Injectors All. Choke controls 1, 2, and 4. Air filters 1, 2, and 4. Fuel-air...

  9. Small size transformer provides high power regulation with low ripple and maximum control

    NASA Technical Reports Server (NTRS)

    Manoli, R.; Ulrich, B. R.

    1971-01-01

    Single, variable, transformer/choke device does work of several. Technique reduces drawer assembly physical size and design and manufacturing cost. Device provides power, voltage current and impedance regulation while maintaining maximum control of linearity and ensuring extremely low ripple. Nulling is controlled to very fine degree.

  10. Aeroacoustic Characteristics of Model Jet Test Facility Flow Conditioners

    NASA Technical Reports Server (NTRS)

    Kinzie, Kevin W.; Henderson, Brenda S.; Haskin, Harry H.

    2005-01-01

    An experimental investigation of flow conditioning devices used to suppress internal rig noise in high speed, high temperature experimental jet facilities is discussed. The aerodynamic and acoustic characteristics of a number of devices including pressure loss and extraneous noise generation are measured. Both aerodynamic and acoustic characteristics are strongly dependent on the porosity of the flow conditioner and the closure ratio of the duct system. For unchoked flow conditioners, the pressure loss follows conventional incompressible flow models. However, for choked flow conditioners, a compressible flow model where the duct and flow conditioner system is modeled as a convergent-divergent nozzle can be used to estimate pressure loss. Choked flow conditioners generate significantly more noise than unchoked conditioners. In addition, flow conditioners with small hole diameters or sintered metal felt material generate less self-noise noise compared to flow conditioners with larger holes.

  11. Automatic tuned MRI RF coil for multinuclear imaging of small animals at 3T.

    PubMed

    Muftuler, L Tugan; Gulsen, Gultekin; Sezen, Kumsal D; Nalcioglu, Orhan

    2002-03-01

    We have developed an MRI RF coil whose tuning can be adjusted automatically between 120 and 128 MHz for sequential spectroscopic imaging of hydrogen and fluorine nuclei at field strength 3 T. Variable capacitance (varactor) diodes were placed on each rung of an eight-leg low-pass birdcage coil to change the tuning frequency of the coil. The diode junction capacitance can be controlled by the amount of applied reverse bias voltage. Impedance matching was also done automatically by another pair of varactor diodes to obtain the maximum SNR at each frequency. The same bias voltage was applied to the tuning varactors on all rungs to avoid perturbations in the coil. A network analyzer was used to monitor matching and tuning of the coil. A Pentium PC controlled the analyzer through the GPIB bus. A code written in LABVIEW was used to communicate with the network analyzer and adjust the bias voltages of the varactors via D/A converters. Serially programmed D/A converter devices were used to apply the bias voltages to the varactors. Isolation amplifiers were used together with RF choke inductors to provide isolation between the RF coil and the DC bias lines. We acquired proton and fluorine images sequentially from a multicompartment phantom using the designed coil. Good matching and tuning were obtained at both resonance frequencies. The tuning and matching of the coil were changed from one resonance frequency to the other within 60 s. (c) 2002 Elsevier Science (USA).

  12. 21 CFR 868.5115 - Device to relieve acute upper airway obstruction.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... the event of choking on a foreign body, can be applied to the abdomen and pushed upward to generate... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Device to relieve acute upper airway obstruction. 868.5115 Section 868.5115 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  13. 21 CFR 868.5115 - Device to relieve acute upper airway obstruction.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Device to relieve acute upper airway obstruction. 868.5115 Section 868.5115 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... the event of choking on a foreign body, can be applied to the abdomen and pushed upward to generate...

  14. Replace the Carburetor Diaphragm. Pulsa-Jet Style with Automatic Choke. Fuel System. Student Manual 2. Small Engine Repair Series. First Edition.

    ERIC Educational Resources Information Center

    Hill, Pamela

    This student manual, part of a small-engine repair series on servicing fuel systems, is designed for use by special needs students in Texas. The manual explains in pictures and short sentences, written on a low reading level, the job of replacing carburetor diaphragms. Along with the steps of this repair job, specific safety and caution…

  15. How PEMEX engineered a deep well completion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antimo A., J.C.

    1971-09-01

    Completion and testing of Petroleos Mexicano's W. Reynosa Well No. 1 in the NE. Frontier District south of the Texas border required engineering innovation to combat the 375/sup 0/F temperatures and pressures near 18,000 psi. Drilled to nearly 18,000 ft, the well was completed and tested below 17,000 ft. Completion plans were designed to determine the economic importance of the reservoir and to provide information and experience in planning future completions to 20,000 ft and deeper. Interval selection was based in part on data acquired during drilling, including lithology, geologic age, rock characteristics, and sensitivity to damage caused by drillingmore » fluids. A set of logs was obtained and evaluated by computer in correlation with mud-log and pressure data. The logs also were correlated with logs from other wells in the area. Pressure gradients in the Reynosa field indicated the possibility of pressures on the order of 10,000 psi, and required the use of specially designed valves rated to 20,000 psi, in conjunction with a casinghead that would permit drilling to the projected depth. A choke manifold consisted of an interchangeable, manually operated positive choke and a set of automatic adjustable chokes. Well conditioning, including cementing, perforating, and well plugging are described.« less

  16. Cavitation in flow through a micro-orifice inside a silicon microchannel

    NASA Astrophysics Data System (ADS)

    Mishra, Chandan; Peles, Yoav

    2005-01-01

    Hydrodynamic cavitation in flows through a micro-orifice entrenched in a microchannel has been detected and experimentally investigated. Microfabrication techniques have been employed to design and develop a microfluidic device containing an 11.5μm wide micro-orifice inside a 100.2μm wide and 101.3μm deep microchannel. The flow of de-ionized water through the micro-orifice reveals the presence of multifarious cavitating flow regimes. This investigation divulges both similarities and differences between cavitation in micro-orifices and cavitation in their macroscale counterparts. The low incipient cavitation number obtained from the current experiments suggests a dominant size scale effect. Choking cavitation is observed to be independent of any pressure or velocity scale effects. However, choking is significantly influenced by the small stream nuclei residence time at such scales. Flow rate choking leads to the establishment of a stationary cavity. Large flow and cavitation hysteresis have been detected at the microscale leading to very high desinent cavitation numbers. The rapid transition from incipient bubbles to choking cavitation and subsequent supercavitation suggests the presence of radically different flow patterns at the microscale. Supercavitation results in a thick cavity, which extends throughout the microchannel, and is encompassed by the liquid. Cavitation at the microscale is expected to considerably influence the design of innovative high-speed microfluidic systems.

  17. Photonic Waveguide Choke Joint with Non-Absorptive Loading

    NASA Technical Reports Server (NTRS)

    Wollack, Edward J. (Inventor); U-Yen, Kongpop (Inventor); Chuss, David T. (Inventor)

    2016-01-01

    A waveguide choke joint includes a first array of pillars positioned on a substrate, each pillar in the first array of pillars having a first size and configured to receive an input plane wave at a first end of the choke joint. The choke joint has a second end configured to transmit the input plane wave away from the choke joint. The choke joint further includes a second array of pillars positioned on the substrate between the first array of pillars and the second end of the choke joint. Each pillar in the second array of pillars has a second size. The choke joint also has a third array of pillars positioned on the substrate between the second array and the second end of the choke joint. Each pillar in the third array of pillars has a third size.

  18. Associations between chronic diseases and choking deaths among older adults in the USA: a cross-sectional study using multiple cause mortality data from 2009 to 2013.

    PubMed

    Wu, Wen-Shiann; Sung, Kuan-Chin; Cheng, Tain-Junn; Lu, Tsung-Hsueh

    2015-11-12

    To examine whether the strengths of the associations between chronic diseases and overall choking differ from those of the associations between chronic diseases and only food-related choking. This cross-sectional study used nationwide multiple cause mortality files. The USA. Older adults aged 65 years or more died between 2009 and 2013. Mortality ratio (observed/expected) of number of deaths from both causes (chronic diseases and choking) and 95% CIs. We identified 76543 deaths for which the death certificates report choking (International Statistical Classification of Diseases and Related Health Problems, Tenth Revision (ICD-10) codes W78, W79 and W80 combined) as a cause of death and only 4974 (6.5%) deaths were classified as food-related choking (ICD-10 code W79). Schizophrenia, Parkinson's disease, Alzheimer's disease and oral cancer are four chronic diseases that had significant associations with both overall and food-related choking. Stroke, larynx cancer and mood (affective) disorders had significant associations with overall choking, but not with food-related choking. We suggest using overall choking instead of only food-related choking to better describe the associations between chronic diseases and choking. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  19. Accidental strangulation in children by the automatic closing of a car window.

    PubMed

    Serena, Kailene; Piva, Jefferson Pedro; Andreolio, Cinara; Carvalho, Paulo Roberto Antonacci; Rocha, Tais Sica da

    2018-03-01

    Among the main causes of death in our country are car accidents, drowning and accidental burns. Strangulation is a potentially fatal injury and an important cause of homicide and suicide among adults and adolescents. In children, its occurrence is usually accidental. However, in recent years, several cases of accidental strangulation in children around the world have been reported. A 2-year-old male patient was strangled in a car window. The patient was admitted to the pediatric intensive care unit with a Glasgow Coma Scale score of 8 and presented with progressive worsening of respiratory dysfunction and torpor. The patient also presented acute respiratory distress syndrome, acute pulmonary edema and shock. He was managed with protective mechanical ventilation, vasoactive drugs and antibiotic therapy. He was discharged from the intensive care unit without neurological or pulmonary sequelae. After 12 days of hospitalization, he was discharged from the hospital, and his state was very good. The incidence of automobile window strangulation is rare but of high morbidity and mortality due to the resulting choking mechanism. Fortunately, newer cars have devices that stop the automatic closing of the windows if resistance is encountered. However, considering the severity of complications strangulated patients experience, the intensive neuro-ventilatory and hemodynamic management of the pathologies involved is important to reduce morbidity and mortality, as is the need to implement new campaigns for the education of parents and caregivers of children, aiming to avoid easily preventable accidents and to optimize safety mechanisms in cars with electric windows.

  20. Finger Foods for Babies

    MedlinePlus

    ... choking and those with little nutritional value. Choking Hazards Parents and caregivers can help prevent choking by ... the baby during eating. Foods that are choking hazards include: pieces of raw vegetables or hard fruits ...

  1. Thermally-Choked Combustor Technology

    NASA Technical Reports Server (NTRS)

    Knuth, William H.; Gloyer, P.; Goodman, J.; Litchford, R. J.

    1993-01-01

    A program is underway to demonstrate the practical feasibility of thermally-choked combustor technology with particular emphasis on rocket propulsion applications. Rather than induce subsonic to supersonic flow transition in a geometric throat, the goal is to create a thermal throat by adding combustion heat in a diverging nozzle. Such a device would have certain advantages over conventional flow accelerators assuming that the pressure loss due to heat addition does not severely curtail propulsive efficiency. As an aid to evaluation, a generalized one-dimensional compressible flow analysis tool was constructed. Simplified calculations indicate that the process is fluid dynamically and thermodynamically feasible. Experimental work is also being carried out in an attempt to develop, assuming an array of practical issues are surmountable, a practical bench-scale demonstrator using high flame speed H2/O2 combustibles.

  2. Choking (For Kids)

    MedlinePlus

    ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body Works ... for Educators Search English Español Choking KidsHealth / For Kids / Choking What's in this article? What Is Choking? ' ...

  3. Prevention of choking among children.

    PubMed

    2010-03-01

    Choking is a leading cause of morbidity and mortality among children, especially those aged 3 years or younger. Food, coins, and toys are the primary causes of choking-related injury and death. Certain characteristics, including shape, size, and consistency, of certain toys and foods increase their potential to cause choking among children. Childhood choking hazards should be addressed through comprehensive and coordinated prevention activities. The US Consumer Product Safety Commission (CPSC) should increase efforts to ensure that toys that are sold in retail store bins, vending machines, or on the Internet have appropriate choking-hazard warnings; work with manufacturers to improve the effectiveness of recalls of products that pose a choking risk to children; and increase efforts to prevent the resale of these recalled products via online auction sites. Current gaps in choking-prevention standards for children's toys should be reevaluated and addressed, as appropriate, via revisions to the standards established under the Child Safety Protection Act, the Consumer Product Safety Improvement Act, or regulation by the CPSC. Prevention of food-related choking among children in the United States has been inadequately addressed at the federal level. The US Food and Drug Administration should establish a systematic, institutionalized process for examining and addressing the hazards of food-related choking. This process should include the establishment of the necessary surveillance, hazard evaluation, enforcement, and public education activities to prevent food-related choking among children. While maintaining its highly cooperative arrangements with the CPSC and the US Department of Agriculture, the Food and Drug Administration should have the authority to address choking-related risks of all food products, including meat products that fall under the jurisdiction of the US Department of Agriculture. The existing National Electronic Injury Surveillance System-All Injury Program of the CPSC should be modified to conduct more-detailed surveillance of choking on food among children. Food manufacturers should design new foods and redesign existing foods to avoid shapes, sizes, textures, and other characteristics that increase choking risk to children, to the extent possible. Pediatricians, dentists, and other infant and child health care providers should provide choking-prevention counseling to parents as an integral part of anticipatory guidance activities.

  4. A visual study of radial inward choked flow of liquid nitrogen

    NASA Technical Reports Server (NTRS)

    Hendricks, R. C.; Simoneau, R. J.; Hsu, Y. Y.

    1973-01-01

    A visual study of the radial inward choked flow of liquid nitrogen was conducted. Data and high speed moving pictures were obtained. The study indicated the following: (1) steady radial inward choked flow seems equivalent to steady choked flow through axisymmetric nozzles, (2) transient choked flows through the radial gap are not uniform and the discharge pattern appears as nonuniform impinging jets, and (3) the critical mass flow rate data for the transient case appear different from those of the steady case.

  5. Automated Airdrop Information Retrieval System-Human Fact ors Database (AAIRS-HFD) (Users Manual)

    DTIC Science & Technology

    1994-09-01

    creeps, or chokes) Pressure Change Disorders Loss of Sensorimotor Abilities Loss of Cognitive/Perceptual Abilities Treatment drug therapy ...physical therapy cognitive therapy biofeedback therapy 73 9. Psychological Factors Situational Awareness altitude awareness Visual/Spatial...on/off valve prebreather Floatation Devices life preserver Scuba Gear Ankle Braces Knee Braces/Pads 82 7. Cargo/Resupply Parachute Assembly

  6. 30 CFR 27.23 - Automatic warning device.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic warning device. 27.23 Section 27.23... Automatic warning device. (a) An automatic warning device shall be suitably constructed for incorporation in... automatic warning device shall include an alarm signal (audible or colored light), which shall be made to...

  7. 30 CFR 27.23 - Automatic warning device.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic warning device. 27.23 Section 27.23... Automatic warning device. (a) An automatic warning device shall be suitably constructed for incorporation in... automatic warning device shall include an alarm signal (audible or colored light), which shall be made to...

  8. 30 CFR 27.23 - Automatic warning device.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic warning device. 27.23 Section 27.23... Automatic warning device. (a) An automatic warning device shall be suitably constructed for incorporation in... automatic warning device shall include an alarm signal (audible or colored light), which shall be made to...

  9. 30 CFR 27.23 - Automatic warning device.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic warning device. 27.23 Section 27.23... Automatic warning device. (a) An automatic warning device shall be suitably constructed for incorporation in... automatic warning device shall include an alarm signal (audible or colored light), which shall be made to...

  10. Linking performance decline to choking: players' perceptions in basketball.

    PubMed

    Fryer, Ashley Marie; Tenenbaum, Gershon; Chow, Graig M

    2018-02-01

    This study was aimed at examining how basketball players view unexpected performance errors in basketball, and under what conditions they perceive them as choking. Fifty-three basketball players were randomly assigned into 2 groups (game half) to evaluate the linkage between performance decline and choking as a function of game-time, score gap and game half. Within each group, players viewed 8 scenario clips, which featured a different player conducting an error, and subsequently rated the extent of performance decline, the instance of choking and the salience of various performance attributions regarding the error. The analysis revealed that choking was most salient in the 2nd half of the game, but an error was perceived as choking more saliently in the beginning of the 2nd half. This trend was also shown for players' perception of performance decline. Players' ratings of the attributions assigned to errors, however, revealed that during the end of the 2nd half, time pressure and lack of concentration were the causes of errors. Overall, the results provide evidence towards a conceptual framework linking performance decline to the perception of choking, and that errors conducted by players are perceived as choking when there is not a salient reason to suggest its occurrence.

  11. Validation of the Choking Risk Assessment and Pneumonia Risk Assessment for adults with Intellectual and Developmental Disability (IDD).

    PubMed

    Sheppard, Justine Joan; Malandraki, Georgia A; Pifer, Paula; Cuff, Jill; Troche, Michelle; Hemsley, Bronwyn; Balandin, Susan; Mishra, Avinash; Hochman, Roberta

    2017-10-01

    Risk assessments are needed to identify adults with intellectual and developmental disability (IDD) at high risk of choking and pneumonia. To describe the development and validation of the Choking Risk Assessment (CRA) and the Pneumonia Risk Assessment (PRA) for adults with IDD. Test items were identified through literature review and focus groups. Five-year retrospective chart reviews identified a positive choking group (PCG), a negative choking group (NCG), a positive pneumonia group (PPG), and a negative pneumonia group (NPG). Participants were tested with the CRA and PRA by clinicians blind to these testing conditions. The CRA and PRA differentiated the PCG (n=93) from the NCG (n=526) and the PPG (n=63) from the NPG (n=209) with high specificity (0.91 and 0.92 respectively) and moderate to average sensitivity (0.53 and 0.62 respectively). Further analyses revealed associations between clinical diagnoses of dysphagia and choking (p=0.043), and pneumonia (p<0.001). The CRA and PRA are reliable, valid risk indicators for choking and pneumonia in adults with IDD. Precautions for mitigating choking and pneumonia risks can be applied selectively thus avoiding undue impacts on quality of life and unnecessary interventions for low risk individuals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Multipacting in a grooved choke joint at SRF gun for BNL ERL prototype

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, W.; Ben-Zvi, I.; Belomestnykh, S.

    2011-03-28

    The 703 MHz superconducting gun for BNL ERL prototype was tested at JLab with and without choke-joint and cathode stalk. Without choke-joint and cathode stalk, the gradient reached was 25 MV/m with Q{sup 0} {approx} 6E9. The gun cathode insertion port is equipped with a grooved choke joint for multipacting suppression. We carried out tests with choke-joint and cathode stalk. The test results show that there are at least two barriers at about 3.5 MV/m and 5 MV/m. We considered several possibilities and finally found that fine details of the grooved shape are important for multipacting suppression. A triangular groovemore » with round crest may cause strong multipacting in the choke-joint at 3.5 MV/m, 5 MV/m and 10 MV/m. This paper presents the primary test results of the gun and discusses the multipacting analysis in the choke-joint. It also suggests possible solutions for the gun and multipacting suppressing for a similar structure.« less

  13. A singular case of asphyxia by choking on a handkerchief: accidental event or suicide to "shut-up" spirits.

    PubMed

    De Donno, A; Marrone, M; Santoro, V; Ostuni, A; Cassano, A; Grattagliano, I; Introna, F

    2017-01-01

    Choking in adults can prove fatal, despite resuscitation attempts. The manner of death can be natural, homicide or accident. When a death is due to choking, one must consider what conditions contributed to or predisposed the person to choking (eg. alcohol, drugs and physical and mental impairments). Homicidal deaths by choking are relatively uncommon, being more frequently accidental. The diagnosis of death by choking is made at autopsy when the airway is found occluded. If the individual had an occluded airway and the object or food was removed during resuscitation, the only way to make the diagnosis would be on the history. Here, we present a case of asphyxia (accidental or suicidal) by choking on a handkerchief in a patient with a long history of schizophrenia. The woman had attempted a previous suicide driven by evil spirits coming from inside her body, especially from the head and throat; in order to "shut-up" the spirit, she was trying to suffocate it with her hands or by a belt from her pants.

  14. Choking - unconscious adult or child over 1 year

    MedlinePlus

    Choking - unconscious adult or child over 1 year; First aid - choking - unconscious adult or child over 1 year; ... or the local emergency number while you begin first aid and CPR. If you are alone, shout for ...

  15. Induction simulation of gas core nuclear engine

    NASA Technical Reports Server (NTRS)

    Poole, J. W.; Vogel, C. E.

    1973-01-01

    The design, construction and operation of an induction heated plasma device known as a combined principles simulator is discussed. This device incorporates the major design features of the gas core nuclear rocket engine such as solid feed, propellant seeding, propellant injection through the walls, and a transpiration cooled, choked flow nozzle. Both argon and nitrogen were used as propellant simulating material, and sodium was used for fuel simulating material. In addition, a number of experiments were conducted utilizing depleted uranium as the fuel. The test program revealed that satisfactory operation of this device can be accomplished over a range of operating conditions and provided additional data to confirm the validity of the gas core concept.

  16. Device for improved air and fuel distribution to a combustor

    DOEpatents

    Laster, Walter R.; Schilp, Reinhard

    2016-05-31

    A flow conditioning device (30, 50, 70, 100, 150) for a can annular gas turbine engine, including a plurality of flow elements (32, 34, 52, 54, 72, 74, 102) disposed in a compressed air flow path (42, 60, 80, 114, 122) leading to a combustor (12), configured such that relative adjustment of at least one flow directing element (32, 52, 72, 110) with respect to an adjacent flow directing element (34, 54, 74, 112, 120) during operation of the gas turbine engine is effective to adjust a level of choking of the compressed air flow path (42, 60, 80, 114, 122).

  17. A visual study of radial inward choked flow of liquid nitrogen.

    NASA Technical Reports Server (NTRS)

    Hendricks, R. C.; Simoneau, R. J.; Hsu, Y. Y.

    1973-01-01

    Data and high speed movies were acquired on pressurized subcooled liquid nitrogen flowing radially inward through a 0.0076 cm gap. The stagnation pressure ranged from 0.7 to 4 MN/sq m. Steady radial inward choked flow appears equivalent to steady choked flow through axisymmetric nozzles. Transient choked flows through the radial gap are not uniform and the discharge pattern appears as nonuniform impinging jets. The critical mass flow rate data for the transient case appear different from those for the steady case. On the mass flow rate vs pressure map, the slope and separation of the isotherms appear to be less for transient than for steady radial choked flow.

  18. Risk and prognostic factors for pneumonia and choking amongst Parkinson's disease patients with dysphagia.

    PubMed

    Goh, Kwang-Hwee; Acharyya, Sanchalika; Ng, Samuel Yong-Ern; Boo, Jasmine Pei-Ling; Kooi, Amanda Hui-Juan; Ng, Hwee-Lan; Li, Wei; Tay, Kay-Yaw; Au, Wing-Lok; Tan, Louis Chew-Seng

    2016-08-01

    To evaluate the time to hospitalisation and baseline factors associated with pneumonia/choking in Parkinson's Disease (PD) patients. Although dysphagia and pneumonia are common problems in PD, scarce research has been performed. A total of 194 PD patients who underwent a VFS evaluation were retrospectively selected. The mode of feeding and admissions for pneumonia/choking were analyzed. Baseline clinical and demographic variables were compared between feeding groups. Kaplan-Meier survival analysis was performed to estimate time to pneumonia/choking. Clinical variables significantly associated with pneumonia/choking free survival were identified using Cox regression. Hospitalisation for pneumonia/choking occurred in 89 out of 194 patients, with the highest admission rate in rejected enteral feeding group (66.7%), followed by enteral feeding (61.8%) and oral feeding (38.8%) groups. The estimates of median time to event were 11, 14, and 47 months for rejected enteral feeding, enteral and oral feeding groups respectively (log-rank test p < 0.001). The rejected enteral feeding group had the highest risk of pneumonia/choking (HR 4.61, 95%CI:2.33-9.08, p < 0.001), followed by enteral feeding group (HR 2.29, 95%CI:1.25-4.19, p = 0.007), when compared to oral feeding group after adjusting for possible confounders. A stepwise Cox regression showed that the rejected enteral feeding (HR 4.89, 95%CI:2.19-10.88, p < 0.001), enteral mode of feeding (HR 2.43, 95%CI:1.11-5.32, p = 0.026), and Charlson weighted index of co-morbidity (HR 1.27, 95%CI:1.03-1.58, p = 0.028) were independently associated with higher hazard of pneumonia/choking. Compliance to feeding recommendations is important to reduce the risk of hospitalisation for pneumonia/choking. The recommended mode of feeding and comorbidity index was significantly associated with pneumonia/choking risk. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. 21 CFR 892.1900 - Automatic radiographic film processor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automatic radiographic film processor. 892.1900... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1900 Automatic radiographic film processor. (a) Identification. An automatic radiographic film processor is a device intended to be used to...

  20. 21 CFR 892.1900 - Automatic radiographic film processor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Automatic radiographic film processor. 892.1900... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1900 Automatic radiographic film processor. (a) Identification. An automatic radiographic film processor is a device intended to be used to...

  1. 21 CFR 892.1900 - Automatic radiographic film processor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Automatic radiographic film processor. 892.1900... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1900 Automatic radiographic film processor. (a) Identification. An automatic radiographic film processor is a device intended to be used to...

  2. 21 CFR 892.1900 - Automatic radiographic film processor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Automatic radiographic film processor. 892.1900... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1900 Automatic radiographic film processor. (a) Identification. An automatic radiographic film processor is a device intended to be used to...

  3. 21 CFR 892.1900 - Automatic radiographic film processor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automatic radiographic film processor. 892.1900... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1900 Automatic radiographic film processor. (a) Identification. An automatic radiographic film processor is a device intended to be used to...

  4. Unintentional strangulation deaths from the "choking game" among youths aged 6-19 years - United States, 1995-2007.

    PubMed

    Toblin, Robin L; Paulozzi, Leonard J; Gilchrist, Julie; Russell, Patricia J

    2008-01-01

    The "choking game" is defined as self-strangulation or strangulation by another person with the hands or a noose to achieve a brief euphoric state caused by cerebral hypoxia. Participants in this activity typically are youths (Andrew & Fallon, 2007). Serious neurologic injury or death can result from engaging in this activity. Recent news media reports have described numerous deaths among youths attributed to the choking game. Because no traditional public health dataset collects data on this practice, CDC used news media reports to estimate the incidence of deaths from the choking game. This report describes the results of that analysis, which identified 82 probable choking-game deaths among youths aged 6-19 years during 1995-2007. Seventy-one (86.6%) of the decedents were male, and the mean age was 13.3 years. Parents, educators, and health-care providers should become familiar with warning signs that youths are playing the choking game (Urkin & Merrick, 2006). Impact of industry: By learning about the risk factors for and warning signs of the choking game, parents, educators, and health-care providers may be able to identify youth at risk for playing the game and prevent future deaths.

  5. 30 CFR 56.19006 - Automatic hoist braking devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic hoist braking devices. 56.19006 Section 56.19006 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Hoisting Hoists § 56.19006 Automatic hoist braking devices. Automatic hoists shall be provided with devices...

  6. 30 CFR 57.19006 - Automatic hoist braking devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic hoist braking devices. 57.19006 Section 57.19006 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Hoisting Hoists § 57.19006 Automatic hoist braking devices. Automatic hoists shall be provided with devices...

  7. Teatime Threats. Choking Incidents at the Evening Meal

    ERIC Educational Resources Information Center

    Guthrie, Susan; Stansfield, Jois

    2017-01-01

    Purpose: To explore caregiver perceptions of the socio-environmental issues around evening meal ("teatime") which influence choking. Methodology: A qualitative study of caregivers witnessing a choking incident was undertaken. Semi-structured interviews explored perceptions of the causes. Data were analysed using thematic analysis.…

  8. 30 CFR 75.1103-3 - Automatic fire sensor and warning device systems; minimum requirements; general.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-3 Automatic fire sensor and warning device systems; minimum requirements; general. Automatic fire sensor and warning device systems installed in belt haulageways of...

  9. 30 CFR 75.1103-3 - Automatic fire sensor and warning device systems; minimum requirements; general.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-3 Automatic fire sensor and warning device systems; minimum requirements; general. Automatic fire sensor and warning device systems installed in belt haulageways of...

  10. 30 CFR 75.1103-3 - Automatic fire sensor and warning device systems; minimum requirements; general.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-3 Automatic fire sensor and warning device systems; minimum requirements; general. Automatic fire sensor and warning device systems installed in belt haulageways of...

  11. 30 CFR 75.1103-3 - Automatic fire sensor and warning device systems; minimum requirements; general.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-3 Automatic fire sensor and warning device systems; minimum requirements; general. Automatic fire sensor and warning device systems installed in belt haulageways of...

  12. 30 CFR 75.1103-4 - Automatic fire sensor and warning device systems; installation; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-4 Automatic fire sensor and warning device systems; installation; minimum requirements. (a) Effective December 31, 2009, automatic fire sensor and warning device...

  13. 30 CFR 75.1103-4 - Automatic fire sensor and warning device systems; installation; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-4 Automatic fire sensor and warning device systems; installation; minimum requirements. (a) Effective December 31, 2009, automatic fire sensor and warning device...

  14. Searching for genetic tolerance to choke in orchardgrass germplasm

    USDA-ARS?s Scientific Manuscript database

    The sexual cycle of the endophyte Epichloe typhina can 'choke' seed production in certain forage and turf grasses. Orchardgrass is susceptible to choke in Oregon's Willamette Valley, with seed yield losses several years ago reported at 9%, but now much higher in older fields. Although development ...

  15. Charging-choke circuit with a crowbar for precision control of voltage

    DOEpatents

    Praeg, W.F.

    1975-11-25

    The operation of a circuit using a charging choke to obtain dc voltages is improved by constructing the circuit to be capable of producing a higher voltage than the desired value and crowbarring the charging choke when the load voltage reaches the desired value.

  16. 30 CFR 250.444 - What are the choke manifold requirements?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Blowout Preventer (bop) System Requirements § 250.444 What are the choke... corrosiveness, volume, and abrasiveness of drilling fluids and well fluids that you may encounter. (b) Choke...

  17. 30 CFR 250.444 - What are the choke manifold requirements?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Blowout Preventer (bop) System Requirements § 250.444 What are the choke manifold..., and abrasiveness of drilling fluids and well fluids that you may encounter. (b) Choke manifold...

  18. 30 CFR 250.444 - What are the choke manifold requirements?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Blowout Preventer (bop) System Requirements § 250.444 What are the choke manifold..., and abrasiveness of drilling fluids and well fluids that you may encounter. (b) Choke manifold...

  19. 30 CFR 250.444 - What are the choke manifold requirements?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Blowout Preventer (bop) System Requirements § 250.444 What are the choke manifold..., and abrasiveness of drilling fluids and well fluids that you may encounter. (b) Choke manifold...

  20. 30 CFR 75.1103-8 - Automatic fire sensor and warning device systems; examination and test requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...

  1. 30 CFR 75.1103-8 - Automatic fire sensor and warning device systems; examination and test requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...

  2. 30 CFR 75.1103-8 - Automatic fire sensor and warning device systems; examination and test requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...

  3. 30 CFR 75.1103-8 - Automatic fire sensor and warning device systems; examination and test requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...

  4. 30 CFR 75.1103-8 - Automatic fire sensor and warning device systems; examination and test requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...

  5. [Study on Intelligent Automatic Tracking Radiation Protection Curtain].

    PubMed

    Zhao, Longyang; Han, Jindong; Ou, Minjian; Chen, Jinlong

    2015-09-01

    In order to overcome the shortcomings of traditional X-ray inspection taking passive protection mode, this paper combines the automatic control technology, puts forward a kind of active protection X-ray equipment. The device of automatic detection of patients receiving X-ray irradiation part, intelligent adjustment in patients and shooting device between automatic tracking radiation protection device height. The device has the advantages of automatic adjustment, anti-radiation device, reduce the height of non-irradiated area X-ray radiation and improve the work efficiency. Testing by the professional organization, the device can decrease more than 90% of X-ray dose for patients with non-irradiated area.

  6. Solitary Participation in the "Choking Game" in Oregon.

    PubMed

    Ibrahim, Alexandra P; Knipper, Sarah H; Brausch, Amy M; Thorne, Elizabeth K

    2016-12-01

    The purpose of this study was to compare characteristics of youth who participate in the choking game alone versus those who participate in a group. Lifetime prevalence estimates were obtained from the 2011 (n = 5682) and 2013 (n = 15 150) Oregon Healthy Teens survey. The 2011 and 2013 data sets were merged (N = 20 832) to compare youth who participate alone versus those who participate in a group in the choking game. Multivariate modeling was conducted to examine individual characteristics of young people who engaged in the choking game alone versus those who engaged in the game in a group. In 2011, 3.8% of eighth-grade participants reported a lifetime prevalence of choking game participation; 3.7% reported lifetime prevalence of participation in 2013. In the merged 2011/2013 data set, 17.6% (n = 93) of choking game participants indicated that they had participated alone. Compared with those who reported participating in a group, youth who participated alone had significantly higher rates of suicide contemplation (odds ratio: 4.58; P < .001) and poor mental health (odds ratio: 2.13; P < .05). Youth who participate alone in the choking game are a particularly high risk group, exhibiting substantially higher rates of suicidal ideation and poorer mental health compared with youth who participate in the choking game in a group. Adolescent health care providers should be aware of these associations, assess whether prevention messaging is appropriate, and be prepared to explain the high risks of morbidity and mortality associated with participation. Copyright © 2016 by the American Academy of Pediatrics.

  7. Unstart phenomena induced by flow choking in scramjet inlet-isolators

    NASA Astrophysics Data System (ADS)

    Im, Seong-kyun; Do, Hyungrok

    2018-02-01

    A review of recent research outcomes in downstream flow choking-driven unstart is presented. Unstart is a flow phenomenon at the inlet that severely reduces the air mass flow rate through the engine, causing a loss of thrust and considerable transient mechanical loading. Therefore, unstart in a scramjet engine crucially affects the design and the operation range of hypersonic vehicles. Downstream flow choking is known to be one of the major mechanisms inducing inlet unstart, as confirmed by recent scramjet-powered flight tests. The current paper examines recent research progress in identifying flow choking mechanisms that trigger unstart. Three different flow choking mechanisms are discussed: flow blockage, mass addition, and heat release from combustion reactions. Current research outcomes on the characteristic of unstarting flows, such as transient and quasi-steady motions, are reviewed for each flow choking mechanism. The characteristics of unstarted flows are described including Buzzing phenomena and oscillatory motions of unstarted shockwaves. Then, the state-of-the-art methods to predict, detect, and control unstart are presented. The review suggests that further investigations with high-enthalpy ground facilities will aid understanding of heat release-driven unstart.

  8. Computer analysis of flow perturbations generated by placement of choke bumps in a wind tunnel

    NASA Technical Reports Server (NTRS)

    Campbell, R. L.

    1981-01-01

    An inviscid analytical study was conducted to determine the upstream flow perturbations caused by placing choke bumps in a wind tunnel. A computer program based on the stream-tube curvature method was used to calculate the resulting flow fields for a nominal free-stream Mach number range of 0.6 to 0.9. The choke bump geometry was also varied to investigate the effect of bump shape on the disturbance produced. Results from the study indicate that a region of significant variation from the free-stream conditions exists upstream of the throat of the tunnel. The extent of the disturbance region was, as a rule, dependent on Mach number and the geometry of the choke bump. In general, the upstream disturbance distance decreased for increasing nominal free-stream Mach number and for decreasing length-to-height ratio of the bump. A polynomial-curve choke bump usually produced less of a disturbance than did a circular-arc bump and going to an axisymmetric configuration (modeling choke bumps on all the tunnel walls) generally resulted in a lower disturbance than with the corresponding two dimensional case.

  9. Indicators of choking risk in adults with learning disabilities: a questionnaire survey and interview study.

    PubMed

    Thacker, Alice; Abdelnoor, Adam; Anderson, Claire; White, Sarah; Hollins, Sheila

    2008-01-01

    Feeding and swallowing impairments are key predictors of increased morbidity and mortality in adults with learning disabilities. This postal survey and interview study sought to identify risk factors in adults with learning disabilities who have histories of choking. A total of 2000 questionnaires were sent to carers of all adults with learning disabilities registered as service users by three local health authorities. (A 'service user' may be using any specialist learning disability health or social care facility with day, residential or therapeutic services). Of the 674 service users for whom surveys were returned, 47 were living in hospital, 396 were living in residential or group homes and 208 were living with relatives, or in their own homes. Eighteen subjects who had reported serious or repeated episodes of choking were interviewed in depth in their residences or workplaces. Responses were subjected to frequency analyses. Personal characteristics were analysed. Choking patterns were differentiated by food texture. A total of 34% of questionnaires on 674 service users were returned; 42% of respondents reported one or more choking episodes. There was a significantly greater occurrence of choking among people with more severe learning disability, with Down syndrome, people who had an incomplete dentition or were taking a greater number of psychotropic drugs. Antisocial eating habits learnt in institutional settings presented an additional choking hazard for some individuals. Choking is a serious hazard for many adults with learning disabilities. This study establishes many of the characteristics associated with swallowing problems in this population. Clinicians and carers should benefit from awareness of these predictors, leading to better management of eating behaviours and habits. A choking and swallowing risk assessment should be included in routine health assessments of adults with learning disability, paying especial attention to the condition of a person's teeth; possible side effects from prescribed medication, and abnormal eating behaviour.

  10. 30 CFR 250.1624 - Blowout prevention equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... station and one BOP-control station on the rig floor; and (5) A choke line and a kill line each equipped with two full-opening valves and a choke manifold. One of the choke-line valves and one of the kill-line valves shall be remotely controlled except that a check valve may be installed on the kill line in...

  11. 30 CFR 250.1624 - Blowout prevention equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... station and one BOP-control station on the rig floor; and (5) A choke line and a kill line each equipped with two full-opening valves and a choke manifold. One of the choke-line valves and one of the kill-line valves shall be remotely controlled except that a check valve may be installed on the kill line in...

  12. 30 CFR 250.1624 - Blowout prevention equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... station and one BOP-control station on the rig floor; and (5) A choke line and a kill line each equipped with two full-opening valves and a choke manifold. One of the choke-line valves and one of the kill-line valves shall be remotely controlled except that a check valve may be installed on the kill line in...

  13. 30 CFR 250.1624 - Blowout prevention equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... station and one BOP-control station on the rig floor; and (5) A choke line and a kill line each equipped with two full-opening valves and a choke manifold. One of the choke-line valves and one of the kill-line valves shall be remotely controlled except that a check valve may be installed on the kill line in...

  14. Choking under monitoring pressure: being watched by the experimenter reduces executive attention.

    PubMed

    Belletier, Clément; Davranche, Karen; Tellier, Idriss S; Dumas, Florence; Vidal, Franck; Hasbroucq, Thierry; Huguet, Pascal

    2015-10-01

    Performing more poorly given one's skill level ("choking") is likely in situations that offer an incentive if a certain outcome is achieved (outcome pressure) or when one is being watched by others-especially when one's performance is being evaluated (monitoring pressure). According to the choking literature, outcome pressure is associated with reduced executive control of attention, whereas monitoring pressure is associated with increased, yet counterproductive, attention to skill processes. Here, we show the first evidence that monitoring pressure-being watched by the experimenter-may lead individuals with higher working memory to choke on a classic measure of executive control-just the task effect thought to result from outcome pressure. Not only does this finding help refine our understanding of the processes underlying choking under monitoring pressure, but it also leads to a new look at classic audience effects, with an important implication for experimental psychology.

  15. 49 CFR 236.739 - Device, acknowledging.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.739... locomotive equipped with an automatic train stop or train control device, an automatic brake application can be forestalled, or by means of which, on a locomotive equipped with an automatic cab signal device...

  16. Choking under the pressure of a positive stereotype: gender identification and self-consciousness moderate men's math test performance.

    PubMed

    Tagler, Michael J

    2012-01-01

    Choking under pressure occurs when an individual underperforms due to situational pressure. The present study examined whether being the target of a positive social stereotype regarding math ability causes choking among men. Gender identification and self-consciousness were hypothesized to moderate the effect of math-gender stereotypes on men's math test performance. Men high in self-consciousness but low in gender identification significantly underperformed when exposed to gender-relevant test instructions. No significant effects were found under a gender-irrelevant condition. These findings are discussed in the contexts of research on stereotype threat, stereotype lift, and choking under pressure.

  17. Mimics of child abuse: Can choking explain abusive head trauma?

    PubMed

    Edwards, George A

    2015-10-01

    Choking is one of the alternative explanations of abusive head trauma in children that have been offered in courtroom testimony and in the media. Most of these explanations - including choking - are not scientifically supported. This article highlights four points. (1) The origins of choking as an explanation for intracranial and retinal hemorrhages are speculative. (2) Choking has been used in high profile court testimony as an explanation for the death of a child thought to have been abused. (3) A case report that proposes choking as an alternative explanation for the death of a child diagnosed with abusive head trauma includes omissions and misrepresentations of facts. (4) There was a decision by the editor of the journal that published the case report that it was not necessary to include all the facts of the case; moreover, the editor indicated that facts are not required when presenting an alternative explanation. The use of scientifically unsupported alternative explanations for abusive head trauma based on inaccurate and biased information constitutes further victimization of the abused child and represents a travesty of justice. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  18. [Stress-induced changes of attention during choking in judo].

    PubMed

    Raschka, C; Mangold, R

    2005-12-01

    The aim of the investigation is the registration and analysis of cognitive parameters in the alarm phase of the stress reaction during a conventional judo cross choking technique. 57 judoka (41 males, 16 females; mean age 23.1 +/- 6.7 years) underwent a standardized cross-choking maneuvre (juji-jime), which lasted for 6 - 8 s until giving up, carried out by a black belt physician. The Stroop inference test was performed before and twice after the intervention. The reading velocity of the interference task was reduced by an average of 77.4 s to a mean of 74.4 s (p < 0.01), and the number of reading errors decreased by a mean from 2.9 to 2.1 (p < 0.01), finally increasing to 2.4 s. The data show the most important improvement in performance in 25 s after choking in the male judoka. In the female judoka increasing performance started already 25 s before choking and continued 25 s after the intervention. The alarm reaction following the potential life threatening stressor with an attack upon the throat improves selective attention before (female subjects) and after choking (female and male subjects) depending on gender.

  19. Health risks of Oregon eighth-grade participants in the "choking game": results from a population-based survey.

    PubMed

    Ramowski, Sarah K; Nystrom, Robert J; Rosenberg, Kenneth D; Gilchrist, Julie; Chaumeton, Nigel R

    2012-05-01

    To examine the risk behaviors associated with participation in the "choking game" by eighth-graders in Oregon. We obtained data from the 2009 Oregon Healthy Teens survey, a cross-sectional weighted survey of 5348 eighth-graders that questioned lifetime prevalence and frequency of choking game participation. The survey also included questions about physical and mental health, gambling, sexual activity, nutrition, physical activity/body image, exposure to violence, and substance use. Lifetime prevalence of choking game participation was 6.1% for Oregon eighth-graders, with no differences between males and females. Of the eighth-grade choking game participants, 64% had engaged in the activity more than once and 26.6% >5 times. Among males, black youth were more likely to participate than white youth. Among both females and males, Pacific Islander youth were much more likely to participate than white youth. Multivariate logistic regression revealed that sexual activity and substance use were significantly associated with choking game participation for both males and females. At >6%, the prevalence of choking game participation among Oregon youth is consistent with previous findings. However, we found that most of those who participate will put themselves at risk more than once. Participants also have other associated health risk behaviors. The comprehensive adolescent well visit, as recommended by the American Academy of Pediatrics, is a good opportunity for providers to conduct a health behavior risk assessment and, if appropriate, discuss the dangers of engaging in this activity.

  20. 30 CFR 75.1103 - Automatic fire warning devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire warning devices. 75.1103 Section... warning devices. [Statutory Provisions] On or before May 29, 1970, devices shall be installed on all such belts which will give a warning automatically when a fire occurs on or near such belt. The Secretary...

  1. 30 CFR 75.1103-5 - Automatic fire warning devices; actions and response.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic fire warning devices; actions and... Protection § 75.1103-5 Automatic fire warning devices; actions and response. (a) When the carbon monoxide... fire sensor and warning device systems shall provide an effective warning signal at the following...

  2. 30 CFR 75.1103 - Automatic fire warning devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic fire warning devices. 75.1103 Section... warning devices. [Statutory Provisions] On or before May 29, 1970, devices shall be installed on all such belts which will give a warning automatically when a fire occurs on or near such belt. The Secretary...

  3. 30 CFR 75.1103-5 - Automatic fire warning devices; actions and response.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire warning devices; actions and... Protection § 75.1103-5 Automatic fire warning devices; actions and response. (a) When the carbon monoxide... fire sensor and warning device systems shall provide an effective warning signal at the following...

  4. 30 CFR 75.1103 - Automatic fire warning devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire warning devices. 75.1103 Section... warning devices. [Statutory Provisions] On or before May 29, 1970, devices shall be installed on all such belts which will give a warning automatically when a fire occurs on or near such belt. The Secretary...

  5. 30 CFR 75.1103 - Automatic fire warning devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire warning devices. 75.1103 Section... warning devices. [Statutory Provisions] On or before May 29, 1970, devices shall be installed on all such belts which will give a warning automatically when a fire occurs on or near such belt. The Secretary...

  6. 30 CFR 75.1103 - Automatic fire warning devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire warning devices. 75.1103 Section... warning devices. [Statutory Provisions] On or before May 29, 1970, devices shall be installed on all such belts which will give a warning automatically when a fire occurs on or near such belt. The Secretary...

  7. Meanline Analysis of Turbines with Choked Flow in the Object-Oriented Turbomachinery Analysis Code

    NASA Technical Reports Server (NTRS)

    Hendricks, Eric S.

    2016-01-01

    The Object-Oriented Turbomachinery Analysis Code (OTAC) is a new meanline/streamline turbomachinery modeling tool being developed at NASA GRC. During the development process, a limitation of the code was discovered in relation to the analysis of choked flow in axial turbines. This paper describes the relevant physics for choked flow as well as the changes made to OTAC to enable analysis in this flow regime.

  8. 30 CFR 77.410 - Mobile equipment; automatic warning devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Mobile equipment; automatic warning devices. 77... UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.410 Mobile equipment; automatic warning... pickup trucks with an unobstructed rear view, shall be equipped with a warning device that— (1) Gives an...

  9. 30 CFR 77.410 - Mobile equipment; automatic warning devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Mobile equipment; automatic warning devices. 77... UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.410 Mobile equipment; automatic warning... pickup trucks with an unobstructed rear view, shall be equipped with a warning device that— (1) Gives an...

  10. 30 CFR 77.410 - Mobile equipment; automatic warning devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Mobile equipment; automatic warning devices. 77... UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.410 Mobile equipment; automatic warning... pickup trucks with an unobstructed rear view, shall be equipped with a warning device that— (1) Gives an...

  11. 30 CFR 77.410 - Mobile equipment; automatic warning devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Mobile equipment; automatic warning devices. 77... UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.410 Mobile equipment; automatic warning... pickup trucks with an unobstructed rear view, shall be equipped with a warning device that— (1) Gives an...

  12. 30 CFR 77.410 - Mobile equipment; automatic warning devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Mobile equipment; automatic warning devices. 77... UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.410 Mobile equipment; automatic warning... pickup trucks with an unobstructed rear view, shall be equipped with a warning device that— (1) Gives an...

  13. Structure Design and Realization of Rapid Medicine Dispensing System

    NASA Astrophysics Data System (ADS)

    Liu, Xiangquan

    In this paper, the main components and function of rapid medicine dispensing system is analyzed, structure design of automatic feeding device, sloping storeroom, automatic dispensing device and automatic sorting device is completed. The system adopts medicine conveyer working in with manipulator to realize automatic batch supply of the boxed medicine, adopts sloping storeroom as warehouse of medicine to realize dense depositing, adopts dispensing mechanism which includes elevator, turning panel and electric magnet to realize rapid medicine dispensing, adopts sorting conveyor belt and sorting device to send medicine to designated outlet.

  14. Basic and Applied Studies of the RAM Accelerator as a Hypervelocity Projectile Launcher

    DTIC Science & Technology

    1993-12-10

    The quasi-steady, one-dimensional "blackbox" model of thermally choked ram accelerator performance 18 that has been widely used by the authors and...the thermal choke point is assumed to be in equilibrium, the conditions can be determined by an equilibrium chemistry combustion routine. This model ...to operation, the details of the flow field must be examined. I The simplest model of the thermally choked ram accelerator flow field treats the flow

  15. Intrapulmonary aquaporin-5 expression as a possible biomarker for discriminating smothering and choking from sudden cardiac death: a pilot study.

    PubMed

    Wang, Qi; Ishikawa, Takaki; Michiue, Tomomi; Zhu, Bao-Li; Guan, Da-Wei; Maeda, Hitoshi

    2012-07-10

    The diagnosis of mechanical asphyxia as a cause of death, especially smothering and choking lacking evident injury, is one of the most difficult tasks in forensic pathology. The present study investigated the intrapulmonary expressions of aquaporins (AQPs; AQP-1 and AQP-5), as markers of water homeostasis, in forensic autopsy cases (total n=64, within 48 h postmortem) of mechanical asphyxiation due to neck compression (strangulation, n=24), including manual/ligature strangulation (n=12) and atypical hanging (n=12), smothering (n=7) and choking (n=8), compared with sudden cardiac death (n=14) and acute brain injury (n=11). Quantification of mRNA using a Taqman real-time PCR assay system demonstrated suppressed expression of AQP-5, but not AQP-1, in smothering and choking, compared with that in strangulation as well as sudden cardiac death and acute brain injury death. Immunostaining of AQP-5 was weakly detected in a linear pattern in the type I alveolar epithelial cells in smothering and choking cases, while cardiac and brain injury death showed marked positivity, and most strangulation cases had AQP-5-positive granular aggregates and fragments in intra-alveolar spaces. These observations indicate a partial difference in pulmonary molecular pathology among these causes of death, suggesting a procedure for possible discrimination of smothering and choking from sudden cardiac death. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  16. The bright and choked gamma-ray burst contribution to the IceCube and ANTARES low-energy excess

    NASA Astrophysics Data System (ADS)

    Denton, Peter B.; Tamborra, Irene

    2018-04-01

    The increasing statistics of the high-energy neutrino flux observed by the IceCube Observatory points towards an excess of events above the atmospheric neutrino background in the 30–400 TeV energy range. Such an excess is compatible with the findings of the ANTARES Telescope and it would naturally imply the possibility that more than one source class contributes to the observed flux. Electromagnetically hidden sources have been invoked to interpret this excess of events at low energies. By adopting a unified model for the electromagnetically bright and choked gamma-ray bursts and taking into account particle acceleration at the internal and collimation shock radii, we discuss whether bright and choked bursts are viable candidates. Our findings suggest that, although producing a copious neutrino flux, choked and bright astrophysical jets cannot be the dominant sources of the excess of neutrino events. A fine tuning of the model parameters or distinct scenarios for choked jets should be invoked in order to explain the low-energy neutrino data of IceCube and ANTARES.

  17. 77 FR 5058 - Agency Information Collection Activities; Submission for OMB Review; Comment Request; Automatic...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-01

    ... for OMB Review; Comment Request; Automatic Fire Sensor and Warning Devices Systems; Examination and..., ``Automatic Fire Sensor and Warning Devices Systems,'' to the Office of Management and Budget (OMB) for review... and warning device systems are maintained and calibrated in order to function properly at all times...

  18. Choking Prevention

    MedlinePlus

    ... Hazard Items Keep items that are choking hazards away from babies and young children. These include: Coins ... to a younger child. Keep the following foods away from children younger than 4 years: Hot dogs ...

  19. Design of Choking Cascade Turns.

    DTIC Science & Technology

    1982-12-01

    L D-R124 792 DESIGN OF CHOK~ING CASCADE TURNSCU) AIR FORCE INST OF v TECH MRIGHT-PAT1TERSON AFB OH SCHOOL OF ENGINEERING J BAIRD DEC 82 AFIT/GRE/AA...82D- 3 DESIGN OF CHOKING *’ CASCADE TURNS THESIS Presented to the Faculty of the School of Enqineerinq of the Air Force Institute of Technoloqy Air ...Approved for public release; distribution unlimited 4* Preface Ramjet engines are being considered by both the Air Force and Navy for tactical air

  20. Combustion Dynamics Behavior in a Single-Element Lean Direct Injection (LDI) Gas Turbine Combustor

    DTIC Science & Technology

    2014-06-01

    Constant mass inflow from a choked orifice Exit Boundary Condition Choked nozzle Diameter of combustor 50.8 mm Diameter of air plenum 25.4 mm A...schematic of the LDI combustor is shown in Fig. 1. It comprises an air inlet section, air plenum, swirler- venturi- injector assembly, combustion chamber...and exit nozzle . Air, heated with an 80 kW electrical heater, enters the combustor through a slotted choked orifice plate, designed to minimize

  1. Numerical Simulations of Flowfields in a Central-Dump Ramjet Combustor. 3. Effects of Chemistry

    DTIC Science & Technology

    1990-07-23

    conditions [1,8]. The choked outflow conditions force the flow to become sonic at the throat of the exit nozzle. The choked outflow conditions force...are realistic because under most operating conditions in practical systems, the flow is choked at the throat of the exit nozzle. Furthermore, it has...timesteps in the early stages of the reactive flow case. The mixture is ignited at the end of timestep 160000. sTrEP .I070 160000 -Z ~ ~ - 36 828

  2. Assessment of choke valve erosion in a high-pressure, high-temperature gas condensate well using TLA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Birchenough, P.M.; Cornally, D.; Dawson, S.G.B.

    1994-12-31

    Many planned new developments in the North Sea will involve the exploitation of hostile high pressure, high temperature gas condensate reserves. The extremely high pressure letdown over the wellhead choke leads to very high flow velocities, and consequent risks of erosion damage occurring to the choke internals. In a recent study, measurements of erosion have been performed during an offshore well test under flowing conditions using advanced Thin Layer Activation techniques and scaled Laboratory tests.

  3. Preliminary Investigation of an Underwater Ramjet Powered by Compressed Air

    NASA Technical Reports Server (NTRS)

    Mottard, Elmo J.; Shoemaker, Charles J.

    1961-01-01

    Part I contains the results of a preliminary experimental investigation of a particular design of an underwater ramjet or hydroduct powered by compressed air. The hydroduct is a propulsion device in which the energy of an expanding gas imparts additional momentum to a stream of water through mixing. The hydroduct model had a fineness ratio of 5.9, a maximum diameter of 3.2 inches, and a ratio of inlet area to frontal area of 0.32. The model was towed at a depth of 1 inch at forward speeds between 20 and 60 feet per second for airflow rates from 0.1 to 0.3 pound per second. Longitudinal force and pressures at the inlet and in the mixing chamber were determined. The hydroduct produced a positive thrust-minus-drag force at every test speed. The force and pressure coefficients were functions primarily of the ratio of weight airflow to free-stream velocity. The maximum propulsive efficiency based on the net internal thrust and an isothermal expansion of the air was approximately 53 percent at a thrust coefficient of 0.10. The performance of the test model may have been influenced by choking of the exit flow. Part II is a theoretical development of an underwater ramjet using air as "fuel." The basic assumption of the theoretical analysis is that a mixture of water and air can be treated as a compressible gas. More information on the properties of air-water mixtures is required to confirm this assumption or to suggest another approach. A method is suggested from which a more complete theoretical development, with the effects of choking included, may be obtained. An exploratory computation, in which this suggested method was used, indicated that the effect of choked flow on the thrust coefficient was minor.

  4. 30 CFR 75.1103-3 - Automatic fire sensor and warning device systems; minimum requirements; general.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire sensor and warning device systems; minimum requirements; general. 75.1103-3 Section 75.1103-3 Mineral Resources MINE SAFETY AND...-UNDERGROUND COAL MINES Fire Protection § 75.1103-3 Automatic fire sensor and warning device systems; minimum...

  5. Choking - infant under 1 year

    MedlinePlus

    ... coughing Soft or high-pitched sounds while inhaling First Aid Do NOT perform these steps if the infant ... see it. DO NOT DO NOT perform choking first aid if the infant is coughing forcefully, has a ...

  6. Variation with Mach Number of Static and Total Pressures Through Various Screens

    NASA Technical Reports Server (NTRS)

    Adler, Alfred A

    1946-01-01

    Tests were conducted in the Langley 24-inch highspeed tunnel to ascertain the static-pressure and total-pressure losses through screens ranging in mesh from 3 to 12 wires per inch and in wire diameter from 0.023 to 0.041 inch. Data were obtained from a Mach number of approximately 0.20 up to the maximum (choking) Mach number obtainable for each screen. The results of this investigation indicate that the pressure losses increase with increasing Mach number until the choking Mach number, which can be computed, is reached. Since choking imposes a restriction on the mass rate of flow and maximum losses are incurred at this condition, great care must be taken in selecting the screen mesh and wire dimmeter for an installation so that the choking Mach number is

  7. Extending Wi-Fi Direct for Automated Operations

    DTIC Science & Technology

    2015-03-01

    functionalities. These added functionalities include: automatic device discovery, a mutual awareness of capabilities between devices (inter-device capability ...functionalities include: automatic device discove1y, a mutual awareness of capabilities between devices (inter-device capability awareness...Figure 7. P2P Device GO Negotiation Request (The P2P IE includes P2P Capability , P2P Device Info, Group Owner Intent, Configuration Timeout, Listen

  8. 76 FR 58301 - Proposed Extension of Existing Information Collection; Automatic Fire Sensor and Warning Device...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-20

    .... Sec. 75.1103-8(b) and (c). MSHA expects to subsume these provisions into OMB 1219-0054, Fire....1103-5(a)(2)(ii) Automatic fire sensor and warning device systems and the package is at OMB for its 3.... 75.1103-5(a) Automatic fire warning devices; actions, response in October 2010; OMB 1219-0127...

  9. A case of choking phobia: towards a conceptual approach.

    PubMed

    Lopes, Rui; Melo, Raquel; Curral, Rosário; Coelho, Rui; Roma-Torres, António

    2014-03-01

    Choking phobia, also known as phagophobia or swallowing phobia is an uncommon clinical entity that has been underappreciated and is included in the new DSM-5 and upcoming ICD-11 diagnostic category of avoidant/restrictive food intake disorder. Phenomenologically distinct from other eating disorders, it is characterized by the phobic stimulus of swallowing that results in the avoidance of food or drinks, and ultimately to low weight, social withdrawal, anxiety and depression states. Its prevalence and long-term course on the general population still needs to be determined, probably reflecting years of indefiniteness regarding its nosology and by the absence of a clear set of diagnostic criteria. We present a clinical case of choking phobia in a 32-year-old male patient after an episode of choke when eating chicken. An early diagnosis and distinction from other eating disorders is important for proper treatment and fundamental for prognosis. We also make a thorough revision on literature in clinical features, differential diagnosis and treatment approaches, suggesting a conceptual approach for choking phobia as a clinical spectrum settled by different degrees of phobic subtypes, which may depend on a varied number of clinical variables.

  10. 30 CFR 250.444 - What are the choke manifold requirements?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations... abrasiveness of drilling fluids and well fluids that you may encounter. (b) Choke manifold components must have...

  11. Evaluation of manual and automatic manually triggered ventilation performance and ergonomics using a simulation model.

    PubMed

    Marjanovic, Nicolas; Le Floch, Soizig; Jaffrelot, Morgan; L'Her, Erwan

    2014-05-01

    In the absence of endotracheal intubation, the manual bag-valve-mask (BVM) is the most frequently used ventilation technique during resuscitation. The efficiency of other devices has been poorly studied. The bench-test study described here was designed to evaluate the effectiveness of an automatic, manually triggered system, and to compare it with manual BVM ventilation. A respiratory system bench model was assembled using a lung simulator connected to a manikin to simulate a patient with unprotected airways. Fifty health-care providers from different professional groups (emergency physicians, residents, advanced paramedics, nurses, and paramedics; n = 10 per group) evaluated manual BVM ventilation, and compared it with an automatic manually triggered device (EasyCPR). Three pathological situations were simulated (restrictive, obstructive, normal). Standard ventilation parameters were recorded; the ergonomics of the system were assessed by the health-care professionals using a standard numerical scale once the recordings were completed. The tidal volume fell within the standard range (400-600 mL) for 25.6% of breaths (0.6-45 breaths) using manual BVM ventilation, and for 28.6% of breaths (0.3-80 breaths) using the automatic manually triggered device (EasyCPR) (P < .0002). Peak inspiratory airway pressure was lower using the automatic manually triggered device (EasyCPR) (10.6 ± 5 vs 15.9 ± 10 cm H2O, P < .001). The ventilation rate fell consistently within the guidelines, in the case of the automatic manually triggered device (EasyCPR) only (10.3 ± 2 vs 17.6 ± 6, P < .001). Significant pulmonary overdistention was observed when using the manual BVM device during the normal and obstructive sequences. The nurses and paramedics considered the ergonomics of the automatic manually triggered device (EasyCPR) to be better than those of the manual device. The use of an automatic manually triggered device may improve ventilation efficiency and decrease the risk of pulmonary overdistention, while decreasing the ventilation rate.

  12. Food choking hazards in children.

    PubMed

    Sidell, Douglas R; Kim, Irene A; Coker, Tumaini R; Moreno, Candice; Shapiro, Nina L

    2013-12-01

    To review the literature on pediatric food choking risks, with the long-term goal of supporting legislation regulating the production, labeling, and distribution of high-risk foods. A PubMed search (Keywords: choking, obstruction, asphyxiation, foreign body, food) was conducted in July-September 2010 with publication dates ranging from 1966 to 2010. Articles related to pediatric foreign body aspiration (FBA) were selected by three independent reviewers. 1145 articles were initially identified. Abstracts were then screened utilizing a tool designed to isolate relevant pediatric choking events; this tool helped to only select abstracts which presented data on patients younger than 18 years of age who had choked on food items. Through this, a total of 72 pertinent articles were isolated (55 observational studies, 17 case reports/series). For each study, patient age, sex, foreign body location, presenting signs and symptoms, utility of radiographic studies, and type of foreign body detected in the majority of study participants were determined. A "majority" of patients for each study was predetermined arbitrarily to be 2/3 of the studied population. The majority of patients in each observational study was determined to be: male (87% of all studies) and age <5 years (95% of all studies). Aspirated foreign bodies were mostly detected in the right main bronchus foreign body (72% of all studies), and there were abnormal radiographic signs (81% of all studies) at the time of evaluation. Food-object foreign bodies were the most frequent factors associated with choking (94% of all studies). Childhood aspiration of food-objects is a significant public health issue. Although there is substantial legislation regulating non-food items that pose a choking hazard, equivalent guidelines do not exist for high-risk foods. Our study identifies and confirms several risk factors for pediatric FBA events. In doing so, it echoes the concerns and suggestions of various groups in supporting the development of legislation which may reduce the incidence of food-object aspiration. Copyright © 2013. Published by Elsevier Ireland Ltd.

  13. A system shift in tidal choking due to the construction of Yangshan Harbour, Shanghai, China

    NASA Astrophysics Data System (ADS)

    Guo, Wenyun; Wang, Xiao Hua; Ding, Pingxing; Ge, Jianzhong; Song, Dehai

    2018-06-01

    Tidal choking is a geometric feature caused by a narrowed channel. Construction of the Yangshan Harbour, Shanghai, China obstructed three key channels and intensively changed the local geometry and topography. In this study nine numerical experiments based on the Finite-Volume Community Ocean Model are conducted to study the project's influence on tidal characteristics. Results show that stronger tidal choking happened at the East Entrance after project, mainly due to the jet induced water-level drop forced by Bernoulli law and the longer and narrower geometry. The stronger tidal choking forces a faster flow and larger tidal energy flux at the choked channel while reducing the tidal amplitude in the Inner Harbour Area (IHA). The scouring on this channel reduces the choking effect but further enlarges tidal energy flux. Moreover, damming the channels decrease the tidal amplitude at the lee side of tidal propagating direction while increasing the amplitude on the stoss side. The dams also decrease the tidal current on both sides, and meanwhile develop two patches with stronger current aside the dam. The project induced changes in tidal characteristics are complex in space, and perturbations in bathymetry increase this complexity. Yangshan Harbour's construction induces little changes in the total tidal energy density in the IHA, but induces obvious changes in the spatial distribution of tidal energy. Although this study is site-specific, the findings may be applicable to tidal dynamics in land reclamation close to open seas, such as the dramatic reclamation of islands in the South China Sea.

  14. 30 CFR 77.211-1 - Continuous methane monitoring device; installation and operation; automatic deenergization of...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Continuous methane monitoring device... Installations § 77.211-1 Continuous methane monitoring device; installation and operation; automatic deenergization of electric equipment. Continuous methane monitoring devices shall be set to deenergize...

  15. 30 CFR 77.211-1 - Continuous methane monitoring device; installation and operation; automatic deenergization of...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Continuous methane monitoring device... Installations § 77.211-1 Continuous methane monitoring device; installation and operation; automatic deenergization of electric equipment. Continuous methane monitoring devices shall be set to deenergize...

  16. Semi-actuator disk theory for compressor choke flutter

    NASA Technical Reports Server (NTRS)

    Micklow, J.; Jeffers, J.

    1981-01-01

    A mathematical anaysis predict the unsteady aerodynamic utilizing semi actuator theory environment for a cascade of airfoils harmonically oscillating in choked flow was developed. A normal shock is located in the blade passage, its position depending on the time dependent geometry, and pressure perturbations of the system. In addition to shock dynamics, the model includes the effect of compressibility, interblade phase lag, and an unsteady flow field upstream and downstream of the cascade. Calculated unsteady aerodynamics were compared with isolated airfoil wind tunnel data, and choke flutter onset boundaries were compared with data from testing of an F100 high pressure compressor stage.

  17. Automatic HDL firmware generation for FPGA-based reconfigurable measurement and control systems with mezzanines in FMC standard

    NASA Astrophysics Data System (ADS)

    Wojenski, Andrzej; Kasprowicz, Grzegorz; Pozniak, Krzysztof T.; Romaniuk, Ryszard

    2013-10-01

    The paper describes a concept of automatic firmware generation for reconfigurable measurement systems, which uses FPGA devices and measurement cards in FMC standard. Following sections are described in details: automatic HDL code generation for FPGA devices, automatic communication interfaces implementation, HDL drivers for measurement cards, automatic serial connection between multiple measurement backplane boards, automatic build of memory map (address space), automatic generated firmware management. Presented solutions are required in many advanced measurement systems, like Beam Position Monitors or GEM detectors. This work is a part of a wider project for automatic firmware generation and management of reconfigurable systems. Solutions presented in this paper are based on previous publication in SPIE.

  18. 30 CFR 27.23 - Automatic warning device.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.23... function automatically at a methane content of the mine atmosphere between 1.0 to 1.5 volume percent and at all higher concentrations of methane. (c) It is recommended that the automatic warning device be...

  19. Safe Kids Worldwide: preventing unintentional childhood injuries across the globe.

    PubMed

    Mickalide, Angela; Carr, Kate

    2012-12-01

    Unintentional injuries are predictable and preventable. Yet every hour, a child in the United States dies from an unintentional injury. Globally, the number is even more staggering, with nearly 1 million children dying from unintentional injuries each year. Motor vehicle-related injuries, burns, drowning, falls, suffocation or choking, and poisoning are just a few of the unintentional injury risks threatening children. Patient safety requires a three-pronged strategy of behavior change, use of safety devices, and improvement of laws and regulations to ensure that all children lead healthy and productive lives. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. A Very Unusual Accidental Mechanical Asphyxia of Choking with a Whole Solea Solea.

    PubMed

    Busardò, Francesco Paolo; Mannocchi, Giulio; Pugnetti, Paola; Santurro, Alessandro; Maggiordomo, Aldo; Zaami, Simona

    2017-03-01

    The case here reported involves a schizophrenic 19-year-old girl under treatment with clotiapine, which was well tolerated except for a moderate dry mouth. The woman ingested a whole sole (Solea solea), which caused a very rapid death by choking. A complete autopsy was performed 24 h later, as well as histological and toxicological analysis. At autopsy, the sole was wedged in the esophagus causing a choking ab extrinseco. The fish had a length of 18 cm and a maximum width of 6 cm, weighing 188.7 g. Toxicological analysis detected 0.57 mg/L of clotiapine in blood, which falls within the therapeutic range. The peculiarity of this case is represented by two factors: one is the choking by fish and the second was the adverse affect caused by clotiapine, which induced a condition of dry mouth making the act of swallowing even more difficult, thereby contributing to a very rapid mechanical asphyxia and the death of the young woman. © 2016 American Academy of Forensic Sciences.

  1. Two-phase choked flow of cryogenic fluids in converging-diverging nozzles

    NASA Technical Reports Server (NTRS)

    Simoneau, R. J.; Hendricks, R. C.

    1979-01-01

    Data are presented for the two phase choked flow of three cryogenic fluids - nitrogen, methane, and hydrogen - in four converging-diverging nozzles. The data cover a range of inlet stagnation conditions, all single phase, from well below to well above the thermodynamic critical conditions. In almost all cases the nozzle throat conditions were two phase. The results indicate that the choked flow rates were not very sensitive to nozzle geometry. However, the axial pressure profiles, especially the throat pressure and the point of vaporization, were very sensitive to both nozzle geometry and operating conditions. A modified Henry-Fauske model correlated all the choked flow rate data to within + or - 10 percent. Neither the equilibrium model nor the Henry-Fauske model predicted throat pressures well over the whole range of data. Above the thermodynamic critical temperature the homogeneous equilibrium model was preferred for both flow rate and pressure ratio. The data of the three fluids could be normalized by the principle of corresponding states.

  2. 49 CFR 236.747 - Forestall.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.747 Forestall. As applied to an automatic train stop or train control device, to prevent an automatic brake application by operation of an acknowledging device or by manual control of the speed of the train. ...

  3. 49 CFR 236.747 - Forestall.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.747 Forestall. As applied to an automatic train stop or train control device, to prevent an automatic brake application by operation of an acknowledging device or by manual control of the speed of the train. ...

  4. A device for automatic photoelectric control of the analytical gap for emission spectrographs

    USGS Publications Warehouse

    Dietrich, John A.; Cooley, Elmo F.; Curry, Kenneth J.

    1977-01-01

    A photoelectric device has been built that automatically controls the analytical gap between electrodes during excitation period. The control device allows for precise control of the analytical gap during the arcing process of samples, resulting in better precision of analysis.

  5. Effects of Multiple Nozzles on Asymmetric Ejector Performance

    NASA Technical Reports Server (NTRS)

    Lineberry, D.; Landrum, B.

    2005-01-01

    This paper presents a comparison of a single nozzle and a dual nozzle strut based ejector. The results are focused on the fluid properties in the ejector duct. The research focused on choking mechanisms, mass flow entrainment, and mixing duct pressure distributions. The two ejectors were tests at equivalent primary mass flow rates. This corresponds to chamber pressures ranging from 100 psi to 900 psi in the single nozzle strut and 50 psi to 450 psi in the dual nozzle strut. Secondary flow was drawn from the lab at atmospheric pressure, and was not controlled. The secondary flow was found to choke at a value of 2.3 lb/s for a primary mass flow rate at approximately 2.1 lb/s for both ejectors. This choke was believed to be a mass addition choke rather than a traditional aerodynamic choke. The mixing duct pressure distribution exhibited two distinct trends at "low pressure" trend and at "high pressure" trend. For the low pressure trend, the mixing length for the ejectors remained fixed around 20 inches, regardless of the chamber pressure. For the higher pressure trend, the mixing length was considerably longer and increased with increasing chamber pressure. At high chamber pressures (high mass flow rates), a supersonic core flow was present at the exit of the duct. For these cases, the two streams did not have time to mix by the end of the duct.

  6. Predictors of Asphyxiation Risk in Adults with Intellectual Disabilities and Dysphagia

    ERIC Educational Resources Information Center

    Samuels, R.; Chadwick, D. D.

    2006-01-01

    Background: Adults with learning disabilities referred for assessment of their eating and drinking are frequently reported to cough and choke when eating and drinking. The research literature investigating dysphagia has often overlooked asphyxiation risk, highlighting coughing and choking as indicators of aspiration only. This is a notable…

  7. 78 FR 28865 - Request for Comment on the Federal Guidelines for Opioid Treatment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-16

    ..., Room 7-1044, Rockville, MD 20857. Please allow sufficient time for mailed comments to be received... Federal Register Representative, Division of Pharmacologic Therapies, 1 Choke Cherry Road, Room 7-1044... Representative, Division of Pharmacologic Therapies, 1 Choke Cherry Road, Room 7-1044, Rockville, MD 20850. To...

  8. A simple and inexpensive pulsing device for data-recording cameras

    Treesearch

    David L. Sonderman

    1973-01-01

    In some areas of forestry and wood utilization research, use of automatic data recording equipment has become commonplace. This research note describes the basic electronic components needed to modify an existing intervalometer into a simplified pulsing device for controlling an automatic data recording camera. The pulsing device is easily assembled and inexpensive,...

  9. Care Staff Perceptions of Choking Incidents: What Details Are Reported?

    ERIC Educational Resources Information Center

    Guthrie, Susan; Lecko, Caroline; Roddam, Hazel

    2015-01-01

    Background: Following a series of fatal choking incidents in one UK specialist service, this study evaluated the detail included in incident reporting. This study compared the enhanced reporting system in the specialist service with the national reporting and learning system. Methods: Eligible reports were selected from a national organization and…

  10. Multipacting-free quarter-wavelength choke joint design for BNL SRF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, W.; Belomestnykh, S.; Ben-Zvi, I.

    The BNL SRF gun cavity operated well in CW mode up to 2 MV. However, its performance suffered due to multipacting in the quarter-wavelength choke joint. A new multipacting-free cathode stalk was designed and conditioned. This paper describes RF and thermal design of the new cathode stalk and its conditioning results.

  11. Constraining high-energy neutrino emission from choked jets in stripped-envelope supernovae

    NASA Astrophysics Data System (ADS)

    Senno, Nicholas; Murase, Kohta; Mészáros, Peter

    2018-01-01

    There are indications that γ-ray dark objects such as supernovae (SNe) with choked jets, and the cores of active galactic nuclei may contribute to the diffuse flux of astrophysical neutrinos measured by the IceCube observatory. In particular, stripped-envelope SNe have received much attention since they are capable of producing relativistic jets and could explain the diversity in observations of collapsar explosions (e.g., gamma-ray bursts (GRBs), low-luminosity GRBs, and Type Ibc SNe). We use an unbinned maximum likelihood method to search for spatial and temporal coincidences between Type Ibc core-collapse SNe, which may harbor a choked jet, and muon neutrinos from a sample of IceCube up-going track-like events measured from May 2011–May 2012. In this stacking analysis, we find no significant deviation from a background-only hypothesis using one year of data, and are able to place upper limits on the total amount of isotropic equivalent energy that choked jet core-collapse SNe deposit in cosmic rays Script Ecr and the fraction of core-collapse SNe which have a jet pointed towards Earth fjet. This analysis can be extended with yet to be made public IceCube data, and the increased amount of optically detected core-collapse SNe discovered by wide field-of-view surveys such as the Palomar Transient Factory and All-Sky Automated Survey for Supernovae. The choked jet SNe/high-energy cosmic neutrino connection can be more tightly constrained in the near future.

  12. Socioeconomic Impact Assessment: Communications Industry. Phase III. Technology Forecast.

    DTIC Science & Technology

    1979-02-02

    8217. Some add-on devices , such as automatic answering systems, have already penetrated the home market substantially. In the future, however, ( major changes ...equipment. This class includes garage door openers, wireless micro- phones , cordless telephones, and radio and TV receivers. These -( devices can...ACUMENICS 1-9 1.2.2 Switching Devices The first automatic switching devices which began to replace operator-switched telephone traffic in the early

  13. 27 CFR 53.61 - Imposition and rates of tax.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... set of sights (iron or optical), sight mount or set of sight mounts, a choke, a flash hider, a muzzle brake, a magazine, a set of sling swivels, and/or an attachable ramrod for muzzle loading firearms when... sights and mounts, recoil pads, slings, sling swivels, chokes, and flash hiders/muzzle brakes of a type...

  14. When Errors Count: An EEG Study on Numerical Error Monitoring under Performance Pressure

    ERIC Educational Resources Information Center

    Schillinger, Frieder L.; De Smedt, Bert; Grabner, Roland H.

    2016-01-01

    In high-stake tests, students often display lower achievements than expected based on their skill level--a phenomenon known as choking under pressure. This imposes a serious problem for many students, especially for test-anxious individuals. Among school subjects, mathematics has been shown to be particularly vulnerable to choking. To succeed in a…

  15. Improved equivalent circuit for twin slot terahertz receivers

    NASA Technical Reports Server (NTRS)

    McGrath, W. R.

    2002-01-01

    Series-fed coplanar waveguide embedding circuits are being developed for terahertz mixers using, in particular, submicron-sized superconducting devices, such as hot electron bolometers as the nonlinear element. Although these mixers show promising performance, they usually also show a considerable downward shift in the center frequency, when compared with simulations obtained by using simplified models. This makes it very difficult to design low-noise mixers for a given THz frequency. This shiftis principally caused by parasitics due to the extremely small details (in terms of wavelength) of the device, and by the electrical properties of the RF choke filter in the DC/IF line. In this paper, we present an improved equivalent network model of such mixer circuits which agrees with measured results at THz frequencies and we propose a new set of THz bolometric mixers that have been fabricated and are currently being tested.

  16. A novel network module for medical devices.

    PubMed

    Chen, Ping-Yu

    2008-01-01

    In order to allow medical devices to upload the vital signs to a server on a network without manually configuring for end-users, a new network module is proposed. The proposed network module, called Medical Hub (MH), functions as a bridge to fetch the data from all connecting medical devices, and then upload these data to the server. When powering on, the MH can immediately establish network configuration automatically. Network Address Translation (NAT) traversal is also supported by the MH with the UPnP Internet Gateway Device (IGD) methodology. Besides the network configuration, other configuration in the MH is automatically established by using the remote management protocol TR-069. On the other hand, a mechanism for updating software automatically according to the variant connected medical device is proposed. With this mechanism, newcome medical devices can be detected and supported by the MH without manual operation.

  17. Translations on USSR Military Affairs, Number 1280

    DTIC Science & Technology

    1977-06-17

    engineer, the conclusion was automatic : he is an undisciplined person. However, this idea was totally inconsistent with the image I had developed of V...pro- jectors, trainers, all sorts of simulators, automatic devices, and so forth. As is known, the technical devices for the mass training and...in the equipment and assemblies. In possessing "feedback," within a few seconds they can record and automatically analyze the actions of the

  18. Choking under Pressure: When an Additional Positive Stereotype Affects Performance for Domain Identified Male Mathematics Students

    ERIC Educational Resources Information Center

    Rosenthal, Harriet E. S.; Crisp, Richard J.

    2007-01-01

    This research aimed to establish if the presentation of two positive stereotypes would result in choking under pressure for identified male mathematics students. Seventy-five 16 year old men, who had just commenced their AS-level study, were either made aware of their gender group membership (single positive stereotype), their school group…

  19. Microwave heating apparatus and method

    DOEpatents

    Johnson, Andrew J.; Petersen, Robert D.; Swanson, Stephen D.

    1990-01-01

    An apparatus is provided for heating and melting materials using microwave energy, and for permitting them to solidify. The apparatus includes a microwave energy source, a resonant cavity having an opening in its floor, a microwave energy choke encompassing the opening in the floor of the cavity, a metal container to hold the materials to be heated and melted, a turntable, and a lift-table. During operation, the combined action of the turntable and the lift-table position the metal container so that the top of the container is level with the floor of the cavity, is in substantial registration with the floor opening, and is encompassed by the microwave energy choke; thus, during operation, the interior of the container defines part of the resonant cavity. Additionally, a screw feeder, extending into the cavity and sheltered from microwave energy by a conveyor choke, may convey the materials to be heated to the container. Also, preferably, the floor of the resonant cavity may include perforatins, so that the offgases and dust generated in the apparatus may be removed from the resonant cavity by pulling outside air between the container choke and the exterior wall of the container into the resonant cavity and out from the cavity through the perforations.

  20. Initiation of combustion in the thermally choked ram accelerator

    NASA Technical Reports Server (NTRS)

    Bruckner, A. P.; Burnham, E. A.; Knowlen, C.; Hertzberg, A.; Bogdanoff, D. W.

    1992-01-01

    The methodology for initiating stable combustion in a ram accelerator operating in the thermally choked mode is presented in this paper. The ram accelerator is a high velocity ramjet-in-tube projectile launcher whose principle of operation is similar to that of an airbreathing ramjet. The subcaliber projectile travels supersonically through a stationary tube filled with a premixed combustible gas mixture. In the thermally choked propulsion mode subsonic combustion takes place behind the base of the projectile and leads to thermal choking, which stabilizes a normal shock system on the projectile, thus producing forward thrust. Projectiles with masses in the 45-90 g range have been accelerated to velocities up to 2650 m/sec in a 38 mm bore, 16 m long accelerator tube. Operation of the ram accelerator is started by injecting the projectile into the accelerator tube at velocities in the 700 - 1300 m/sec range by means of a conventional gas gun. A specially designed obturator, which seals the bore of the gun during this initial acceleration, enters the ram accelerator together with the projectile. The interaction of the obturator with the propellant gas ignites the gas mixture and establishes stable combustion behind the projectile.

  1. 75 FR 68200 - Medical Devices; Radiology Devices; Reclassification of Full-Field Digital Mammography System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-05

    ... exposure control, image processing and reconstruction programs, patient and equipment supports, component..., acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and... may include was revised by adding automatic exposure control, image processing and reconstruction...

  2. 49 CFR 236.564 - Acknowledging time.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Locomotives § 236.564 Acknowledging time. Acknowledging time of intermittent automatic train-stop device shall be not more than 30 seconds. ...

  3. 49 CFR 236.830 - Time, acknowledging.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.830 Time, acknowledging. As applied to an intermittent automatic train stop system, a predetermined time within which an automatic brake application may be forestalled by means of the acknowledging device. ...

  4. Vibration analysis on automatic take-up device of belt conveyor

    NASA Astrophysics Data System (ADS)

    Qin, Tailong; Wei, Jin

    2008-10-01

    Through introducing application condition of belt conveyor in the modern mining industry, the paper proposed, in the dynamic course of its starting, braking or loading, it would produce moving tension and elastic wave. And analyzed the factors cause the automatic take-up device of belt conveyor vibrating: the take-up device's structure and the elastic wave. Finally the paper proposed the measure to reduce vibration and carried on the modeling and simulation on the tension buffer device.

  5. Emergency management of chemical weapons injuries.

    PubMed

    Anderson, Peter D

    2012-02-01

    The potential for chemical weapons to be used in terrorism is a real possibility. Classes of chemical weapons include nerve agents, vesicants (blister agents), choking agents, incapacitating agents, riot control agents, blood agents, and toxic industrial chemicals. The nerve agents work by blocking the actions of acetylcholinesterase leading to a cholinergic syndrome. Nerve agents include sarin, tabun, VX, cyclosarin, and soman. The vesicants include sulfur mustard and lewisite. The vesicants produce blisters and also damage the upper airways. Choking agents include phosgene and chlorine gas. Choking agents cause pulmonary edema. Incapacitating agents include fentanyl and its derivatives and adamsite. Riot control agents include Mace and pepper spray. Blood agents include cyanide. The mechanism of toxicity for cyanide is blocking oxidative phosphorylation. Toxic industrial chemicals include agents such as formaldehyde, hydrofluoric acid, and ammonia.

  6. Direct Machining of Low-Loss THz Waveguide Components With an RF Choke.

    PubMed

    Lewis, Samantha M; Nanni, Emilio A; Temkin, Richard J

    2014-12-01

    We present results for the successful fabrication of low-loss THz metallic waveguide components using direct machining with a CNC end mill. The approach uses a split-block machining process with the addition of an RF choke running parallel to the waveguide. The choke greatly reduces coupling to the parasitic mode of the parallel-plate waveguide produced by the split-block. This method has demonstrated loss as low as 0.2 dB/cm at 280 GHz for a copper WR-3 waveguide. It has also been used in the fabrication of 3 and 10 dB directional couplers in brass, demonstrating excellent agreement with design simulations from 240-260 GHz. The method may be adapted to structures with features on the order of 200 μm.

  7. Terminal-shock and restart control of a Mach 2.5, axisymmetric, mixed compression inlet with 40 percent internal contraction. [wind tunnel tests

    NASA Technical Reports Server (NTRS)

    Baumbick, R. J.

    1974-01-01

    Results of experimental tests conducted on a supersonic, mixed-compression, axisymmetric inlet are presented. The inlet is designed for operation at Mach 2.5 with a turbofan engine (TF-30). The inlet was coupled to either a choked orifice plate or a long duct which had a variable-area choked exit plug. Closed-loop frequency responses of selected diffuser static pressures used in the terminal-shock control system are presented. Results are shown for Mach 2.5 conditions with the inlet coupled to either the choked orifice plate or the long duct. Inlet unstart-restart traces are also presented. High-response inlet bypass doors were used to generate an internal disturbance and also to achieve terminal-shock control.

  8. "Choking Game" Yields Varying Responses from Educators: Some Fear Addressing the Dangerous Activity Could Prompt Copycats

    ERIC Educational Resources Information Center

    Samuels, Christina A.

    2006-01-01

    A spate of deaths among young people around the country in the past year has brought further media attention to an asphyxial activity known as "the choking game." But the subject is a sensitive one for schools. Some administrators have actively enlisted in efforts to inform students and parents about the risks of practices like the…

  9. 49 CFR 236.534 - Entrance to equipped territory; requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Roadway § 236.534... not exceed restricted speed, the automatic train stop, train control, or cab signal device shall be...

  10. 49 CFR 236.562 - Minimum rail current required.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Locomotives § 236.562 Minimum... continuous inductive automatic train stop or train control device to normal condition or to obtain a proceed...

  11. 49 CFR 236.534 - Entrance to equipped territory; requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Roadway § 236.534... not exceed restricted speed, the automatic train stop, train control, or cab signal device shall be...

  12. 49 CFR 236.562 - Minimum rail current required.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Locomotives § 236.562 Minimum... continuous inductive automatic train stop or train control device to normal condition or to obtain a proceed...

  13. Modifications to the nozzle test chamber to extend nozzle static-test capability

    NASA Technical Reports Server (NTRS)

    Keyes, J. W.

    1985-01-01

    The nozzle test chamber was modified to provide a high-pressure-ratio nozzle static-test capability. Experiments were conducted to determine the range of the ratio of nozzle total pressure to chamber pressure and to make direct nozzle thrust measurements using a three-component strain-gage force balance. Pressure ratios from 3 to 285 were measured with several axisymmetric nozzles at a nozzle total pressure of 15 to 190 psia. Devices for measuring system mass flow were calibrated using standard axisymmetric convergent choked nozzles. System mass-flow rates up to 10 lbm/sec are measured. The measured thrust results of these nozzles are in good agreement with one-dimensional theoretical predictions for convergent nozzles.

  14. 49 CFR 236.586 - Daily or after trip test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.586 Daily or after trip test..., each locomotive equipped with an automatic cab signal or train stop or train control device operating...

  15. 49 CFR 236.557 - Receiver; location with respect to rail.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Locomotives § 236.557 Receiver... automatic cab signal, train stop, or train control device of locomotive equipped with onboard test equipment...

  16. 49 CFR 236.586 - Daily or after trip test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.586 Daily or after trip test..., each locomotive equipped with an automatic cab signal or train stop or train control device operating...

  17. Pressure distribution in a converging-diverging nozzle during two-phase choked flow of subcooled nitrogen

    NASA Technical Reports Server (NTRS)

    Simoneau, R. J.

    1975-01-01

    Choked flow rates and axial pressure distributions were measured for subcooled nitrogen in a converging-diverging nozzle with a constant area section in the throat region. Stagnation pressures ranged from slightly above saturation to twice the thermodynamic critical pressure. Stagnation temperatures ranged from 0.75 to 1.03 times the thermodynamic critical temperature. The choking plane is at the divergence end of the constant area throat section. At high stagnation pressures the fluid stays liquid well into the constant area throat region; at near saturation stagnation pressures it appears that vaporization occurs at or before the entrance to the constant area throat region. The throat-to-stagnation pressure ratio data exhibits an anomalous flat region, and this anomaly is related to the two-phase process. The fluid is metastably all liquid below the saturation pressure.

  18. A 915-MHz antenna for microwave thermal ablation treatment: physical design, computer modeling and experimental measurement.

    PubMed

    Pisa, S; Cavagnaro, M; Bernardi, P; Lin, J C

    2001-05-01

    A 915-MHz antenna design that produces specific absorption rate distributions with preferential power deposition in tissues surrounding and including the distal end of the catheter antenna is described. The design features minimal reflected microwave current from the antenna flowing up the transmission line. This cap-choke antenna consists of an annular cap and a coaxial choke which matches the antenna to the coaxial transmission line. The design minimizes heating of the coaxial cable and its performance is not affected by the depth of insertion of the antenna into tissue. The paper provides a comparison of results obtained from computer modeling and experimental measurements made in tissue equivalent phantom materials. There is excellent agreement between numerical modeling and experimental measurement. The cap-choke, matched-dipole type antenna is suitable for intracavitary microwave thermal ablation therapy.

  19. Neutrinos from Choked Jets Accompanied by Type-II Supernovae

    NASA Astrophysics Data System (ADS)

    He, Hao-Ning; Kusenko, Alexander; Nagataki, Shigehiro; Fan, Yi-Zhong; Wei, Da-Ming

    2018-04-01

    The origin of the IceCube neutrinos is still an open question. Upper limits from diffuse gamma-ray observations suggest that the neutrino sources are either distant or hidden from gamma-ray observations. It is possible that the neutrinos are produced in jets that are formed in core-collapsing massive stars and fail to break out, the so-called choked jets. We study neutrinos from the jets choked in the hydrogen envelopes of red supergiant stars. Fast photo-meson cooling softens the neutrino spectrum, making it hard to explain the PeV neutrinos observed by IceCube in a one-component scenario, but a two-component model can explain the spectrum. Furthermore, we predict that a newly born jet-driven type-II supernova may be observed to be associated with a neutrino burst detected by IceCube.

  20. Large - scale Rectangular Ruler Automated Verification Device

    NASA Astrophysics Data System (ADS)

    Chen, Hao; Chang, Luping; Xing, Minjian; Xie, Xie

    2018-03-01

    This paper introduces a large-scale rectangular ruler automated verification device, which consists of photoelectric autocollimator and self-designed mechanical drive car and data automatic acquisition system. The design of mechanical structure part of the device refer to optical axis design, drive part, fixture device and wheel design. The design of control system of the device refer to hardware design and software design, and the hardware mainly uses singlechip system, and the software design is the process of the photoelectric autocollimator and the automatic data acquisition process. This devices can automated achieve vertical measurement data. The reliability of the device is verified by experimental comparison. The conclusion meets the requirement of the right angle test procedure.

  1. 49 CFR 236.825 - System, automatic train control.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false System, automatic train control. 236.825 Section..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.825 System, automatic train control. A system so arranged that its operation will automatically...

  2. 49 CFR 236.825 - System, automatic train control.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false System, automatic train control. 236.825 Section..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.825 System, automatic train control. A system so arranged that its operation will automatically...

  3. 49 CFR 236.552 - Insulation resistance; requirement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic... control system, or automatic train stop system shall be not less than one megohm, and that of an... system, automatic train control system, or automatic train stop system, and 20,000 ohms for an...

  4. IR signature study of aircraft engine for variation in nozzle exit area

    NASA Astrophysics Data System (ADS)

    Baranwal, Nidhi; Mahulikar, Shripad P.

    2016-01-01

    In general, jet engines operate with choked nozzle during take-off, climb and cruise, whereas unchoking occurs while landing and taxiing (when engine is not running at full power). Appropriate thrust in an aircraft in all stages of the flight, i.e., take-off, climb, cruise, descent and landing is achieved through variation in the nozzle exit area. This paper describes the effect on thrust and IR radiance of a turbojet engine due to variation in the exit area of a just choked converging nozzle (Me = 1). The variations in the nozzle exit area result in either choking or unchoking of a just choked converging nozzle. Results for the change in nozzle exit area are analyzed in terms of thrust, mass flow rate and specific fuel consumption. The solid angle subtended (Ω) by the exhaust system is estimated analytically, for the variation in nozzle exit area (Ane), as it affects the visibility of the hot engine parts from the rear aspect. For constant design point thrust, IR radiance is studied from the boresight (ϕ = 0°, directly from the rear side) for various percentage changes in nozzle exit area (%ΔAne), in the 1.9-2.9 μm and 3-5 μm bands.

  5. Fluid-structure interaction analysis and lifetime estimation of a natural gas pipeline centrifugal compressor under near-choke and near-surge conditions

    NASA Astrophysics Data System (ADS)

    Ju, Yaping; Liu, Hui; Yao, Ziyun; Xing, Peng; Zhang, Chuhua

    2015-11-01

    Up to present, there have been no studies concerning the application of fluid-structure interaction (FSI) analysis to the lifetime estimation of multi-stage centrifugal compressors under dangerous unsteady aerodynamic excitations. In this paper, computational fluid dynamics (CFD) simulations of a three-stage natural gas pipeline centrifugal compressor are performed under near-choke and near-surge conditions, and the unsteady aerodynamic pressure acting on impeller blades are obtained. Then computational structural dynamics (CSD) analysis is conducted through a one-way coupling FSI model to predict alternating stresses in impeller blades. Finally, the compressor lifetime is estimated using the nominal stress approach. The FSI results show that the impellers of latter stages suffer larger fluctuation stresses but smaller mean stresses than those at preceding stages under near-choke and near-surge conditions. The most dangerous position in the compressor is found to be located near the leading edge of the last-stage impeller blade. Compressor lifetime estimation shows that the investigated compressor can run up to 102.7 h under the near-choke condition and 200.2 h under the near-surge condition. This study is expected to provide a scientific guidance for the operation safety of natural gas pipeline centrifugal compressors.

  6. Automated single-slide staining device. [in clinical bacteriology

    NASA Technical Reports Server (NTRS)

    Wilkins, J. R.; Mills, S. M.

    1975-01-01

    An automatic single-slide Gram staining device is described. A timer-actuated solenoid controls the dispensing of gentian violet, Gram iodine solution, decolorizer, and 1% aqueous safranin in proper sequence and for the time required for optimum staining. The amount of stain or reagent delivered is controlled by means of stopcocks below each solenoid. Used stains and reagents can be flushed automatically or manually. Smears Gram stained automatically are equal in quality to those prepared manually. The time to complete one Gram cycle is 4.80 min.

  7. An automatic bolus injector for use in radiotracer studies of blood flow: design and evaluation.

    PubMed

    Snyder, R E; Overton, T R; Boisvert, D P; Petruk, K C

    1976-12-01

    An electromechanical device is described which automatically injects the radiotracer bolus used in the measurement of cerebral blood flow. It consists of two electronically controlled, solenoid operated syringes, one containing the radiotracer solution and the other heparinized saline. Results are presented which show that use of the automatic bolus injector in place of hand injection leads to an improvement in the precision of measured flow values. Additional advantages of the device are discussed.

  8. Methods of visualizing graphs

    DOEpatents

    Wong, Pak C.; Mackey, Patrick S.; Perrine, Kenneth A.; Foote, Harlan P.; Thomas, James J.

    2008-12-23

    Methods for visualizing a graph by automatically drawing elements of the graph as labels are disclosed. In one embodiment, the method comprises receiving node information and edge information from an input device and/or communication interface, constructing a graph layout based at least in part on that information, wherein the edges are automatically drawn as labels, and displaying the graph on a display device according to the graph layout. In some embodiments, the nodes are automatically drawn as labels instead of, or in addition to, the label-edges.

  9. A randomized trial of the effect of automated ventricular capture on device longevity and threshold measurement in pacemaker patients.

    PubMed

    Koplan, Bruce A; Gilligan, David M; Nguyen, Luc S; Lau, Theodore K; Thackeray, Lisa M; Berg, Kellie Chase

    2008-11-01

    An automatic capture (AC) algorithm adjusts ventricular pacing output to capture the ventricle while optimizing output to 0.5 V above threshold. AC maintains this output and confirms capture on a beat-to-beat basis in bipolar and unipolar pacing and sensing. To assess the AC algorithm and its impact on device longevity. Patients implanted with a pacemaker were randomized 1:1 to have the AC feature on or off for 12 months. Two threshold tests were conducted at each visit- automatic threshold and manual threshold. Average ventricular voltage output and projected device longevity were compared between AC on and off using nonparametric tests. Nine hundred ten patients were enrolled and underwent device implantation. Average ventricular voltage output was 1.6 V for the AC on arm (n = 444) and 3.1 V for the AC off arm (n = 446) (P < 0.001). Projected device longevity was 10.3 years for AC on and 8.9 years for AC off (P < 0.0001), or a 16% increase in longevity for AC on. The proportion of patients in whom there was a difference between automatic threshold and manual threshold of

  10. Enhanced Virtual Presence for Immersive Visualization of Complex Situations for Mission Rehearsal

    DTIC Science & Technology

    1997-06-01

    taken. We propose to join both these technologies together in a registration device . The registration device would be small and portable and easily...registering the panning of the camera (or other sensing device ) and also stitch together the shots to automatically generate panoramic files necessary to...database and as the base information changes each of the linked drawings is automatically updated. Filename Format A specific naming convention should be

  11. 49 CFR 236.506 - Release of brakes after automatic application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.506 Release of brakes after automatic application. The automatic train stop or train control apparatus shall prevent release of the...

  12. 49 CFR 236.826 - System, automatic train stop.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false System, automatic train stop. 236.826 Section 236..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.826 System, automatic train stop. A system so arranged that its operation will automatically...

  13. 49 CFR 236.506 - Release of brakes after automatic application.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.506 Release of brakes after automatic application. The automatic train stop or train control apparatus shall prevent release of the...

  14. 49 CFR 236.826 - System, automatic train stop.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false System, automatic train stop. 236.826 Section 236..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.826 System, automatic train stop. A system so arranged that its operation will automatically...

  15. 30 CFR 75.1103-5 - Automatic fire warning devices; actions and response.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... level reaches 10 parts per million above the established ambient level at any sensor location, automatic fire sensor and warning device systems shall provide an effective warning signal at the following... endangered and (ii) A map or schematic that shows the locations of sensors, and the intended air flow...

  16. 49 CFR 236.560 - Contact element, mechanical trip type; location with respect to rail.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and.... Contact element of automatic train stop device of the mechanical trip type shall be maintained at a height...

  17. 49 CFR 236.567 - Restrictions imposed when device fails and/or is cut out en route.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions... restricted speed or if an automatic block signal system is in operation according to signal indication but...

  18. 30 CFR 75.1103-5 - Automatic fire warning devices; actions and response.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... hours after the belt is stopped, unless an examination for hot rollers and fire is made as prescribed in... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire warning devices; actions and... OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire...

  19. 30 CFR 75.1103-5 - Automatic fire warning devices; actions and response.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... hours after the belt is stopped, unless an examination for hot rollers and fire is made as prescribed in... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire warning devices; actions and... OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire...

  20. Daylight control system device and method

    DOEpatents

    Paton, John Douglas

    2007-03-13

    A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.

  1. Daylight control system, device and method

    DOEpatents

    Paton, John Douglas

    2012-08-28

    A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.

  2. Daylight control system device and method

    DOEpatents

    Paton, John Douglas

    2009-12-01

    A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.

  3. System for pressure letdown of abrasive slurries

    DOEpatents

    Kasper, Stanley

    1991-01-01

    A system and method for releasing erosive slurries from containment at high pressure without subjecting valves to highly erosive slurry flow. The system includes a pressure letdown tank disposed below the high-pressure tank, the two tanks being connected by a valved line communicating the gas phases and a line having a valve and choke for a transfer of liquid into the letdown tank. The letdown tank has a valved gas vent and a valved outlet line for release of liquid. In operation, the gas transfer line is opened to equalize pressure between tanks so that a low level of liquid flow occurs. The letdown tank is then vented, creating a high-pressure differential between the tanks. At this point, flow between tanks is controlled by the choke. High-velocity, erosive flow through a high-pressure outlet valve is prevented by equalizing the start up pressure and thereafter limiting flow with the choke.

  4. Identification and Analysis of National Airspace System Resource Constraints

    NASA Technical Reports Server (NTRS)

    Smith, Jeremy C.; Marien, Ty V.; Viken, Jeffery K.; Neitzke, Kurt W.; Kwa, Tech-Seng; Dollyhigh, Samuel M.; Fenbert, James W.; Hinze, Nicolas K.

    2015-01-01

    This analysis is the deliverable for the Airspace Systems Program, Systems Analysis Integration and Evaluation Project Milestone for the Systems and Portfolio Analysis (SPA) focus area SPA.4.06 Identification and Analysis of National Airspace System (NAS) Resource Constraints and Mitigation Strategies. "Identify choke points in the current and future NAS. Choke points refer to any areas in the en route, terminal, oceanic, airport, and surface operations that constrain actual demand in current and projected future operations. Use the Common Scenarios based on Transportation Systems Analysis Model (TSAM) projections of future demand developed under SPA.4.04 Tools, Methods and Scenarios Development. Analyze causes, including operational and physical constraints." The NASA analysis is complementary to a NASA Research Announcement (NRA) "Development of Tools and Analysis to Evaluate Choke Points in the National Airspace System" Contract # NNA3AB95C awarded to Logistics Management Institute, Sept 2013.

  5. Multipacting simulation and test results of BNL 704 MHz SRF gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu W.; Belomestnykh, S.; Ben-Zvi, I.

    The BNL 704MHz SRF gun has a grooved choke joint to support the photo-cathode. Due to the distortion of grooves at the choke joint during the BCP for the choke joint, several multipacting barriers showed up when it was tested with Nb cathode stalk at JLab. We built a setup to use the spare large grain SRF cavity to test and condition the multipacting at BNL with various power sources up to 50kW. The test is carried out in three stages: testing the cavity performance without cathode, testing the cavity with the Nb cathode stalk that was used at Jlab,more » and testing the cavity with a copper cathode stalk that is based on the design for the SRF gun. This paper summarizes the results of multipacting simulation, and presents the large grain cavity test setup and the test results.« less

  6. The Choking Game on YouTube: An Update.

    PubMed

    Defenderfer, Ellen K; Austin, Jillian E; Davies, W Hobart

    2016-01-01

    The choking game (TCG) is an adolescent activity in which asphyxiation is used to obtain a "high," occasionally resulting in seizures or death. A plethora of TCG information is available through YouTube, though this content has not been evaluated recently. The current study described TCG as portrayed in YouTube videos and compared views and ratings of TCG videos to unrelated videos. The TCG videos demonstrated diverse methods of asphyxiation, with a minority showing injury to the participants. TCG videos were less likely to be commented on or rated positively than non-choking game videos. TCG prevention videos differed significantly from actual TCG videos in the way they depicted the social context of TCG. Thus, TCG videos are accessible through YouTube, but the prevention materials available on YouTube are not accurate or representative. Accurate and educational online prevention materials should be created to decrease the occurrence of TCG.

  7. Choking under social pressure: social monitoring among the lonely.

    PubMed

    Knowles, Megan L; Lucas, Gale M; Baumeister, Roy F; Gardner, Wendi L

    2015-06-01

    Lonely individuals may decode social cues well but have difficulty putting such skills to use precisely when they need them--in social situations. In four studies, we examined whether lonely people choke under social pressure by asking participants to complete social sensitivity tasks framed as diagnostic of social skills or nonsocial skills. Across studies, lonely participants performed worse than nonlonely participants on social sensitivity tasks framed as tests of social aptitude, but they performed just as well or better than the nonlonely when the same tasks were framed as tests of academic aptitude. Mediational analyses in Study 3 and misattribution effects in Study 4 indicate that anxiety plays an important role in this choking effect. This research suggests that lonely individuals may not need to acquire social skills to escape loneliness; instead, they must learn to cope with performance anxiety in interpersonal interactions. © 2015 by the Society for Personality and Social Psychology, Inc.

  8. Significance of coupling device for vessel anastomosis in esophageal reconstruction.

    PubMed

    Watanabe, Y; Horiuchi, A; Yamamoto, Y; Kikkawa, H; Kusunose, H; Sugishita, H; Sato, K; Yoshida, M; Yukumi, S; Kawachi, K

    2005-01-01

    To prevent an anastomotic failure due to impaired blood supply, several trials have been performed such as preoperative ischemic conditioning by transarterial embolization of the left gastric, right gastric and splenic arteries or microvascular anastomosis. We assess the significance of an automatic anastomotic coupling device for vessel anastomosis, which we have continuously utilized, to simplify the task and shorten the anastomotic time since March 1999. 8 patients who underwent venous anastomosis by an automatic anastomotic coupling device were evaluated for the time of anastomosis, total ischemic time and outcomes. Venous anastomosis was completed within 5 minutes on average. Microscopic arterial anastomosis by hand took 35 minutes on average. For gastric tube reconstruction, venous anastomosis by an automatic coupling device took only 5 minutes. The top of the gastric tube showed congestion before venous anastomosis, but rapidly recovered from it after anastomosis. Postoperative endoscopic observation of the mucosal color of the replaced intestine or gastric tube was started 3 days after surgery and revealed no ischemia or congestion. The postoperative course was uneventful except one case suffering from pneumonia but leakage was not observed in any case. An automatic anastomotic coupling device can perform an easy and reliable vascular anastomosis for patients who undergo esophageal reconstruction. The device may shorten the operating time and consequently the ischemic time of the gastric tube or jejunal or colonic graft, which in turn may lead to a decrease of complications.

  9. 49 CFR 236.502 - Automatic brake application, initiation by restrictive block conditions stopping distance in...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.502 Automatic brake application, initiation by restrictive block conditions stopping distance in advance. An automatic train-stop or train-control system shall operate to...

  10. STOLAND

    NASA Technical Reports Server (NTRS)

    Grgurich, J.; Bradbury, P.

    1976-01-01

    The STOLAND system includes air data, navigation, guidance, flight director (including a throttle flight director on the Augmentor Wing), 3-axis autopilot and autothrottle functions. The 3-axis autopilot and autothrottle control through parallel electric servos on both aircraft and on the augmentor wing, the system also interfaces with three electrohydraulic series actuators which drive the roll control surfaces, elevator and rudder. The system incorporates automatic configuration control of the flaps and nozzles on the augmentor wing and of the flaps on the Twin Otter. Interfaces are also provided to control the wing flap chokes on the Augmentor Wing and the spoilers on the Twin Otter. The STOLAND system has all the capabilities of a conventional integrated avionics system. Aircraft stabilization is provided in pitch, roll and yaw including control wheel steering in pitch and roll. The basic modes include altitude hold and select, indicated airspeed hold and select, flight path angle hold and select, and heading hold and select. The system can couple to TACAN and VOR/DME navaids for conventional radial flying.

  11. An automatic camera device for measuring waterfowl use

    USGS Publications Warehouse

    Cowardin, L.M.; Ashe, J.E.

    1965-01-01

    A Yashica Sequelle camera was modified and equipped with a timing device so that it would take pictures automatically at 15-minute intervals. Several of these cameras were used to photograph randomly selected quadrats located in different marsh habitats. The number of birds photographed in the different areas was used as an index of waterfowl use.

  12. Quasi-one-dimensional compressible flow across face seals and narrow slots. 1: Analysis

    NASA Technical Reports Server (NTRS)

    Zuk, J.; Ludwig, L. P.; Johnson, R. L.

    1972-01-01

    An analysis is presented for compressible fluid flow across shaft face seals and narrow slots. The analysis includes fluid inertia, viscous friction, and entrance losses. Subsonic and choked flow conditions can be predicted and analyzed. The model is valid for both laminar and turbulent flows. Results agree with experiment and with solutions which are more limited in applicability. Results show that a parallel film can have a positive film stiffness under choked flow conditions.

  13. Photonic Waveguide Choke Joint with Absorptive Loading

    NASA Technical Reports Server (NTRS)

    Wollack, Edward J. (Inventor); U-Yen, Kongpop (Inventor); Chuss, David T. (Inventor)

    2016-01-01

    A photonic waveguide choke includes a first waveguide flange member having periodic metal tiling pillars, a dissipative dielectric material positioned within an area between the periodic metal tiling pillars and a second waveguide flange member disposed to be coupled with the first waveguide flange member and in spaced-apart relationship separated by a gap. The first waveguide flange member has a substantially smooth surface, and the second waveguide flange member has an array of two-dimensional pillar structures formed therein.

  14. 30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire sensors; actuation of fire...

  15. 30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire sensors; actuation of fire... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems...

  16. 30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire sensors; actuation of fire... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems...

  17. 30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic fire sensors; actuation of fire... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems...

  18. 30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire sensors; actuation of fire... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems...

  19. An Automatic Occlusion Device for Remote Control of Tumor Tissue Ischemia

    PubMed Central

    El-Dahdah, Hamid; Wang, Bei; He, Guanglong; Xu, Ronald X.

    2015-01-01

    We developed an automatic occlusion device for remote control of tumor tissue ischemia. The device consists of a flexible cannula encasing a shape memory alloy wire with its distal end connected to surgical suture. Regional tissue occlusion was tested on both the benchtop and the animal models. In the benchtop test, the occlusion device introduced quantitative and reproducible changes of blood flow in a tissue simulating phantom embedding a vessel simulator. In the animal test, the device generated a cyclic pattern of reversible ischemia in the right hinder leg tissue of a black male C57BL/6 mouse. We also developed a multimodal detector that integrates near infrared spectroscopy and electron paramagnetic resonance spectroscopy for continuous monitoring of tumor tissue oxygenation, blood content, and oxygen tension changes. The multimodal detector was tested on a cancer xenograft nude mouse undergoing reversible tumor ischemia. The automatic occlusion device and the multi-modal detector can be potentially integrated for closed-loop feedback control of tumor tissue ischemia. Such an integrated occlusion device may be used in multiple clinical applications such as regional hypoperfusion control in tumor resection surgeries and thermal ablation processes. In addition, the proposed occlusion device can also be used as a research tool to understand tumor oxygen transport and hemodynamic characteristics. PMID:20082532

  20. Automatic Frequency Controller for Power Amplifiers Used in Bio-Implanted Applications: Issues and Challenges

    PubMed Central

    Hannan, Mahammad A.; Hussein, Hussein A.; Mutashar, Saad; Samad, Salina A.; Hussain, Aini

    2014-01-01

    With the development of communication technologies, the use of wireless systems in biomedical implanted devices has become very useful. Bio-implantable devices are electronic devices which are used for treatment and monitoring brain implants, pacemakers, cochlear implants, retinal implants and so on. The inductive coupling link is used to transmit power and data between the primary and secondary sides of the biomedical implanted system, in which efficient power amplifier is very much needed to ensure the best data transmission rates and low power losses. However, the efficiency of the implanted devices depends on the circuit design, controller, load variation, changes of radio frequency coil's mutual displacement and coupling coefficients. This paper provides a comprehensive survey on various power amplifier classes and their characteristics, efficiency and controller techniques that have been used in bio-implants. The automatic frequency controller used in biomedical implants such as gate drive switching control, closed loop power control, voltage controlled oscillator, capacitor control and microcontroller frequency control have been explained. Most of these techniques keep the resonance frequency stable in transcutaneous power transfer between the external coil and the coil implanted inside the body. Detailed information including carrier frequency, power efficiency, coils displacement, power consumption, supplied voltage and CMOS chip for the controllers techniques are investigated and summarized in the provided tables. From the rigorous review, it is observed that the existing automatic frequency controller technologies are more or less can capable of performing well in the implant devices; however, the systems are still not up to the mark. Accordingly, current challenges and problems of the typical automatic frequency controller techniques for power amplifiers are illustrated, with a brief suggestions and discussion section concerning the progress of implanted device research in the future. This review will hopefully lead to increasing efforts towards the development of low powered, highly efficient, high data rate and reliable automatic frequency controllers for implanted devices. PMID:25615728

  1. Single-Cylinder Oil-Control Tests of Porous Chrome-Plated Cylinder Barrels for Radial Air-Cooled Engines

    DTIC Science & Technology

    1946-01-01

    plating, it will affect a choke as desired in the cylinder. When the clearance between the anode and the cathode (cylinder barrel) is decreased, an...National Advisory Commltteo for Aeronautics, Cltivel« oid , Ohio. RSFEFKICE3 1. Johnson, Robert L., wad Anderson, Roy I.: S.’.nglo-Cylindor Engine Tests...plating a choke in the bore. Choice la obtained by decreasing the clear- ance between the anode and the cylinder barrel ( cathode ). Taper on anode la

  2. [Strangulation marks in homicides caused by choking ? On an irritant blood stain picture].

    PubMed

    Metter, D

    1988-01-01

    Three homicides and one attempted homicide by choking in which apparent signs of throttling were present on the skin of the neck are described. The victims wore slender necklaces which were pressed against the skin by the hands of the perpetrator, causing transverse hematomas and cutaneous abrasions. The following criterious are typical for simulated signs of throttling: similarity to objects on the neck, incomplete course around the neck, absence of coarctation of the soft tissues, no lesions of subcutaneous structures.

  3. Application of the principle of corresponding states to two phase choked flow

    NASA Technical Reports Server (NTRS)

    Hendricks, R. C.; Simoneau, R. J.

    1973-01-01

    It is pointed out that several fluids including methane, oxygen, and nitrogen appear to form an average parametric plot which indicates that the isenthalpic Joule-Thomson coefficient must nearly obey the principle of corresponding states. With this as a basis, it was assumed that there could be several thermodynamic flow processes which nearly obey the principle. An examination was made to determine whether two-phase choked flow could be one of them. The analysis is described and the results are given.

  4. Waveguide Photonic Choke Joint with Wide Out-of-Band Rejection

    NASA Technical Reports Server (NTRS)

    U-yen, Kongpop; Wollack, Edward J.

    2015-01-01

    A photonic choke joint structure with a wide-stop-band is proposed for use as a waveguide flange interface. The structure consists of arrays of square metal pillars arranged in a periodic pattern to suppress the dominant-mode wave propagation in parallel-plate waveguide over a wide frequency bandwidth. The measurement results at microwave frequencies confirm that the structure can provide broadband suppression of more than 56dB over 6.25 times its operating frequency. Applications at millimeter wavelength are discussed.

  5. Waveguide Photonic Choke Joint with Wide Out-of-Band Rejection

    NASA Technical Reports Server (NTRS)

    U-yen, Kongpop; Wollack, Edward J.

    2015-01-01

    A photonic choke joint structure with a wide- stop-band is proposed for use as a waveguide flange interface. The structure consists of arrays of square metal pillars arranged in a periodic pattern to suppress the dominant-mode wave propagation in parallel-plate waveguide over a wide frequency bandwidth. The measurement results at microwave frequencies confirm the structure can provide broadband suppression, more than 56 dB over 6.25 times its operating frequency. Applications at millimeter wavelength are discussed.

  6. 61. VIEW LOOKING NORTHWEST AT A SIGNAL REACTOR OR CHOKE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    61. VIEW LOOKING NORTHWEST AT A SIGNAL REACTOR OR CHOKE COIL. WITHIN THE PROTECTIVE ENCLOSURE IS AN AIR AND PORCELAIN INSULATED COIL OF 5/8' DIAMETER STRANDED COPPER WIRE. REACTOR COILS WERE PLACED IN SERIES WITH EACH LEG OF THREE PHASE GENERATORS. THEIR FUNCTION WAS TO MODERATE SURGES OF CURRENT CAUSED BY LIGHTNING STRIKES, OPEN OR SHORT CIRCUIT PROBLEMS ON THE LINE. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  7. [Wearable Automatic External Defibrillators].

    PubMed

    Luo, Huajie; Luo, Zhangyuan; Jin, Xun; Zhang, Leilei; Wang, Changjin; Zhang, Wenzan; Tu, Quan

    2015-11-01

    Defibrillation is the most effective method of treating ventricular fibrillation(VF), this paper introduces wearable automatic external defibrillators based on embedded system which includes EGG measurements, bioelectrical impedance measurement, discharge defibrillation module, which can automatic identify VF signal, biphasic exponential waveform defibrillation discharge. After verified by animal tests, the device can realize EGG acquisition and automatic identification. After identifying the ventricular fibrillation signal, it can automatic defibrillate to abort ventricular fibrillation and to realize the cardiac electrical cardioversion.

  8. Automatic feedback to promote safe walking and speech loudness control in persons with multiple disabilities: two single-case studies.

    PubMed

    Lancioni, Giulio E; Singh, Nirbhay N; O'Reilly, Mark F; Green, Vanessa A; Alberti, Gloria; Boccasini, Adele; Smaldone, Angela; Oliva, Doretta; Bosco, Andrea

    2014-08-01

    Assessing automatic feedback technologies to promote safe travel and speech loudness control in two men with multiple disabilities, respectively. The men were involved in two single-case studies. In Study I, the technology involved a microprocessor, two photocells, and a verbal feedback device. The man received verbal alerting/feedback when the photocells spotted an obstacle in front of him. In Study II, the technology involved a sound-detecting unit connected to a throat and an airborne microphone, and to a vibration device. Vibration occurred when the man's speech loudness exceeded a preset level. The man included in Study I succeeded in using the automatic feedback in substitution of caregivers' alerting/feedback for safe travel. The man of Study II used the automatic feedback to successfully reduce his speech loudness. Automatic feedback can be highly effective in helping persons with multiple disabilities improve their travel and speech performance.

  9. Automatic Mechetronic Wheel Light Device

    DOEpatents

    Khan, Mohammed John Fitzgerald

    2004-09-14

    A wheel lighting device for illuminating a wheel of a vehicle to increase safety and enhance aesthetics. The device produces the appearance of a "ring of light" on a vehicle's wheels as the vehicle moves. The "ring of light" can automatically change in color and/or brightness according to a vehicle's speed, acceleration, jerk, selection of transmission gears, and/or engine speed. The device provides auxiliary indicator lights by producing light in conjunction with a vehicle's turn signals, hazard lights, alarm systems, and etc. The device comprises a combination of mechanical and electronic components and can be placed on the outer or inner surface of a wheel or made integral to a wheel or wheel cover. The device can be configured for all vehicle types, and is electrically powered by a vehicle's electrical system and/or battery.

  10. Variable area light reflecting assembly

    DOEpatents

    Howard, T.C.

    1986-12-23

    Device is described for tracking daylight and projecting it into a building. The device tracks the sun and automatically adjusts both the orientation and area of the reflecting surface. The device may be mounted in either a wall or roof of a building. Additionally, multiple devices may be employed in a light shaft in a building, providing daylight to several different floors. The preferred embodiment employs a thin reflective film as the reflecting device. One edge of the reflective film is fixed, and the opposite end is attached to a spring-loaded take-up roller. As the sun moves across the sky, the take-up roller automatically adjusts the angle and surface area of the film. Additionally, louvers may be mounted at the light entrance to the device to reflect incoming daylight in an angle perpendicular to the device to provide maximum reflective capability when daylight enters the device at non-perpendicular angles. 9 figs.

  11. Variable area light reflecting assembly

    DOEpatents

    Howard, Thomas C.

    1986-01-01

    Device for tracking daylight and projecting it into a building. The device tracks the sun and automatically adjusts both the orientation and area of the reflecting surface. The device may be mounted in either a wall or roof of a building. Additionally, multiple devices may be employed in a light shaft in a building, providing daylight to several different floors. The preferred embodiment employs a thin reflective film as the reflecting device. One edge of the reflective film is fixed, and the opposite end is attached to a spring-loaded take-up roller. As the sun moves across the sky, the take-up roller automatically adjusts the angle and surface area of the film. Additionally, louvers may be mounted at the light entrance to the device to reflect incoming daylight in an angle perpendicular to the device to provide maximum reflective capability when daylight enters the device at non-perpendicular angles.

  12. Hysteria, or "suffocation of the mother".

    PubMed Central

    Merskey, H; Merskey, S J

    1993-01-01

    OBJECTIVE: To understand or explain the surprising adherence of prominent physicians throughout the centuries to terms suggesting that the womb could move and cause suffocation, choking or difficulty in swallowing. DATA SOURCES: Hippocratic writings on hysterical symptoms and the views of subsequent authors and contexts surrounding such views. DATA SYNTHESIS: Physicians who followed Hippocrates repeatedly related difficulties in breathing or choking and difficulties in swallowing to the uterus, although most recognized that the womb did not rise out of the pelvis, except partially, when enlarged by pregnancy. Respiratory and gastrointestinal symptoms were often associated with anxiety. The effects may have been attributed to the womb, because it was recognized that the womb, when enlarged, can cause difficulty in breathing. Anxiety was also reported more often in women and may have been attributed to the womb for that reason. CONCLUSION: The suffocation of the mother can be understood as anxiety with dyspnea, and globus hystericus reflects anxiety with a choking sensation or difficulty in swallowing. PMID:8439911

  13. Automatic controls and regulators: A compilation

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Devices, methods, and techniques for control and regulation of the mechanical/physical functions involved in implementing the space program are discussed. Section one deals with automatic controls considered to be, essentially, start-stop operations or those holding the activity in a desired constraint. Devices that may be used to regulate activities within desired ranges or subject them to predetermined changes are dealt with in section two.

  14. Research methodology simplification for teaching purposes illustrated by clutch automatic control device testing

    NASA Astrophysics Data System (ADS)

    Wojs, J.

    2016-09-01

    The paper proves that simplified, shorter examination of an object, feasible in laboratory classes, can produce results similar to those reached in scientific investigation of the device using extensive equipment. A thorough investigation of an object, an automatic clutch device in this case, enabled identifying the magnitudes that most significantly affect its operation. The knowledge of these most sensitive magnitudes allows focusing in the teaching process on simplified measurement of only selected magnitudes and verifying the given object in the positive or negative.

  15. Loss of Arctic sea ice causing punctuated change in sightings of killer whales (Orcinus orca) over the past century.

    PubMed

    Higdon, Jeff W; Ferguson, Steven H

    2009-07-01

    Killer whales (Orcinus orca) are major predators that may reshape marine ecosystems via top-down forcing. Climate change models predict major reductions in sea ice with the subsequent expectation for readjustments of species' distribution and abundance. Here, we measure changes in killer whale distribution in the Hudson Bay region with decreasing sea ice as an example of global readjustments occurring with climate change. We summarize records of killer whales in Hudson Bay, Hudson Strait, and Foxe Basin in the eastern Canadian Arctic and relate them to an historical sea ice data set while accounting for spatial and temporal autocorrelation in the data. We find evidence for "choke points," where sea ice inhibits killer whale movement, thereby creating restrictions to their Arctic distribution. We hypothesize that a threshold exists in seasonal sea ice concentration within these choke points that results in pulses in advancements in distribution of an ice-avoiding predator. Hudson Strait appears to have been a significant sea ice choke point that opened up .approximately 50 years ago allowing for an initial punctuated appearance of killer whales followed by a gradual advancing distribution within the entire Hudson Bay region. Killer whale sightings have increased exponentially and are now reported in the Hudson Bay region every summer. We predict that other choke points will soon open up with continued sea ice melt producing punctuated predator-prey trophic cascades across the Arctic.

  16. 49 CFR 236.504 - Operation interconnected with automatic block-signal system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.504... or train control system shall operate in connection with an automatic block signal system and shall...

  17. 49 CFR 235.5 - Changes requiring filing of application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... system, automatic train stop, train control, or cab signal system or other similar appliance or device..., automatic train stop, train control, or cab signal system; or (3) The modification of a block signal system, interlocking, traffic control system, automatic train stop, train control, or cab signal system. (b) [Reserved...

  18. 49 CFR 235.5 - Changes requiring filing of application.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... system, automatic train stop, train control, or cab signal system or other similar appliance or device..., automatic train stop, train control, or cab signal system; or (3) The modification of a block signal system, interlocking, traffic control system, automatic train stop, train control, or cab signal system. (b) [Reserved...

  19. 49 CFR 236.824 - System, automatic block signal.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false System, automatic block signal. 236.824 Section..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.824 System, automatic block signal. A block signal system wherein the use of each block is...

  20. 49 CFR 236.824 - System, automatic block signal.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false System, automatic block signal. 236.824 Section..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.824 System, automatic block signal. A block signal system wherein the use of each block is...

  1. 49 CFR 236.824 - System, automatic block signal.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false System, automatic block signal. 236.824 Section..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.824 System, automatic block signal. A block signal system wherein the use of each block is...

  2. Eye-tracking for clinical decision support: A method to capture automatically what physicians are viewing in the EMR.

    PubMed

    King, Andrew J; Hochheiser, Harry; Visweswaran, Shyam; Clermont, Gilles; Cooper, Gregory F

    2017-01-01

    Eye-tracking is a valuable research tool that is used in laboratory and limited field environments. We take steps toward developing methods that enable widespread adoption of eye-tracking and its real-time application in clinical decision support. Eye-tracking will enhance awareness and enable intelligent views, more precise alerts, and other forms of decision support in the Electronic Medical Record (EMR). We evaluated a low-cost eye-tracking device and found the device's accuracy to be non-inferior to a more expensive device. We also developed and evaluated an automatic method for mapping eye-tracking data to interface elements in the EMR (e.g., a displayed laboratory test value). Mapping was 88% accurate across the six participants in our experiment. Finally, we piloted the use of the low-cost device and the automatic mapping method to label training data for a Learning EMR (LEMR) which is a system that highlights the EMR elements a physician is predicted to use.

  3. Automatic illumination compensation device based on a photoelectrochemical biofuel cell driven by visible light

    NASA Astrophysics Data System (ADS)

    Yu, You; Han, Yanchao; Xu, Miao; Zhang, Lingling; Dong, Shaojun

    2016-04-01

    Inverted illumination compensation is important in energy-saving projects, artificial photosynthesis and some forms of agriculture, such as hydroponics. However, only a few illumination adjustments based on self-powered biodetectors that quantitatively detect the intensity of visible light have been reported. We constructed an automatic illumination compensation device based on a photoelectrochemical biofuel cell (PBFC) driven by visible light. The PBFC consisted of a glucose dehydrogenase modified bioanode and a p-type semiconductor cuprous oxide photocathode. The PBFC had a high power output of 161.4 μW cm-2 and an open circuit potential that responded rapidly to visible light. It adjusted the amount of illumination inversely irrespective of how the external illumination was changed. This rational design of utilizing PBFCs provides new insights into automatic light adjustable devices and may be of benefit to intelligent applications.Inverted illumination compensation is important in energy-saving projects, artificial photosynthesis and some forms of agriculture, such as hydroponics. However, only a few illumination adjustments based on self-powered biodetectors that quantitatively detect the intensity of visible light have been reported. We constructed an automatic illumination compensation device based on a photoelectrochemical biofuel cell (PBFC) driven by visible light. The PBFC consisted of a glucose dehydrogenase modified bioanode and a p-type semiconductor cuprous oxide photocathode. The PBFC had a high power output of 161.4 μW cm-2 and an open circuit potential that responded rapidly to visible light. It adjusted the amount of illumination inversely irrespective of how the external illumination was changed. This rational design of utilizing PBFCs provides new insights into automatic light adjustable devices and may be of benefit to intelligent applications. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr00759g

  4. 10 CFR 431.242 - Test Procedures [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... upstream of the draft control device of an individual, automatically operated, fossil fuel-fired appliance... intended for installation in the venting system of an individual, automatically operated, fossil fuel-fired...

  5. 10 CFR 431.242 - Test Procedures [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... upstream of the draft control device of an individual, automatically operated, fossil fuel-fired appliance... intended for installation in the venting system of an individual, automatically operated, fossil fuel-fired...

  6. Technology for noninvasive mechanical ventilation: looking into the black box

    PubMed Central

    Navajas, Daniel; Montserrat, Josep M.

    2016-01-01

    Current devices for providing noninvasive respiratory support contain sensors and built-in intelligence for automatically modifying ventilation according to the patient's needs. These devices, including automatic continuous positive airway pressure devices and noninvasive ventilators, are technologically complex and offer a considerable number of different modes of ventilation and setting options, the details of which are sometimes difficult to capture by the user. Therefore, better predicting and interpreting the actual performance of these ventilation devices in clinical application requires understanding their functioning principles and assessing their performance under well controlled bench test conditions with simulated patients. This concise review presents an updated perspective of the theoretical basis of intelligent continuous positive airway pressure and noninvasive ventilation devices, and of the tools available for assessing how these devices respond under specific ventilation phenotypes in patients requiring breathing support. PMID:27730162

  7. Analytical study of pressure balancing in gas film seals

    NASA Technical Reports Server (NTRS)

    Zuk, J.

    1973-01-01

    The load factor is investigated for subsonic and choked flow conditions, laminar and turbulent flows, and various seal entrance conditions. Both parallel sealing surfaces and surfaces with small linear deformation were investigated. The load factor for subsonic flow depends strongly on pressure ratio; under choked flow conditions, however the load factor is found to depend more strongly on film thickness and flow entrance conditions rather than pressure ratio. The importance of generating hydrodynamic forces to keep the seal balanced under severe and multipoint operation is also discussed.

  8. [Recommendations for the prevention of organic foreign bodies aspiration].

    PubMed

    Rodríguez, Hugo; Cuestas, Giselle; Gregori, Darío; Lorenzoni, Giulia; Tortosa, Susana; Rodríguez D'Aquila, Máximo; Rodríguez D'Aquila, Juan A; Carrera, Sandra; Passali, Desiderio

    2017-10-01

    Foreign body aspiration remains a common and potentially serious pediatric problem. Most aspirated foreign bodies are food. The education of parents and caregivers about choking hazards and how to avoid them is critical to reduce the incidence of these events. The pediatricians play a key role in promoting injury prevention. We indicate the main characteristics of hazardous food and we present recommendations on age-appropriate meals, adequate forms of food preparation and behavioral rules at mealtimes in order to reduce food choking. Sociedad Argentina de Pediatría.

  9. Computer program for quasi-one-dimensional compressible flow with area change and friction - Application to gas film seals

    NASA Technical Reports Server (NTRS)

    Zuk, J.; Smith, P. J.

    1974-01-01

    A computer program is presented for compressible fluid flow with friction and area change. The program carries out a quasi-one-dimensional flow analysis which is valid for laminar and turbulent flows under both subsonic and choked flow conditions. The program was written to be applied to gas film seals. The area-change analysis should prove useful for choked flow conditions with small mean thickness, as well as for face seals where radial area change is significant. The program is written in FORTRAN 4.

  10. Proceedings of the NATO Advanced Study Institute on High-Brightness Accelerators Held in Pitlochry, Scotland on 13-25 July 1986. Series B. Volume 178

    DTIC Science & Technology

    1986-07-25

    parasites (trichinosis) Improvement in technological properties of food HIGH DOSE (10-50 kGy) Sterilization for commercial purposes Elimination of viruses ...instance, D37 equals 30-80 Gy for Eschercheria coli, 1 kGy for bacillus mesentericus spores, and 4 kGy for tobacco mosaic virus (Casarett, 1968...HF CHOKE CORONA SHIEL DS9 RF ELECTRODE ACCELERATING CHAMBER L j RF CHOKE I RESONANT COIL Fig. 16. Principle of operation: the Dynamitron. of insulator

  11. A study on ship automatic berthing with assistance of auxiliary devices

    NASA Astrophysics Data System (ADS)

    Tran, Van Luong; Im, Namkyun

    2012-09-01

    The recent researches on the automatic berthing control problems have used various kinds of tools as a control method such as expert system, fuzzy logic controllers and artificial neural network (ANN). Among them, ANN has proved to be one of the most effective and attractive options. In a marine context, the berthing maneuver is a complicated procedure in which both human experience and intensive control operations are involved. Nowadays, in most cases of berthing operation, auxiliary devices are used to make the schedule safer and faster but none of above researches has taken into account. In this study, ANN is applied to design the controllers for automatic ship berthing using assistant devices such as bow thruster and tug. Using back-propagation algorithm, we trained ANN with set of teaching data to get a minimal error between output values and desired values of four control outputs including rudder, propeller revolution, bow thruster and tug. Then, computer simulations of automatic berthing were carried out to verify the effecttiveness of the system. The results of the simulations showed good performance for the proposed berthing control system.

  12. 49 CFR 236.401 - Automatic block signal system and interlocking standards applicable to traffic control systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Traffic Control Systems Standards § 236.401 Automatic... 49 Transportation 4 2011-10-01 2011-10-01 false Automatic block signal system and interlocking standards applicable to traffic control systems. 236.401 Section 236.401 Transportation Other Regulations...

  13. 21 CFR 886.1760 - Ophthalmic refractometer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1760 Ophthalmic refractometer. (a) Identification. An ophthalmic refractometer is an automatic AC-powered device that consists of a fixation system... of the eye by measuring light reflexes from the retina. (b) Classification. Class I (general controls...

  14. What Is a Ventricular Assist Device?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  15. Seamless presentation capture, indexing, and management

    NASA Astrophysics Data System (ADS)

    Hilbert, David M.; Cooper, Matthew; Denoue, Laurent; Adcock, John; Billsus, Daniel

    2005-10-01

    Technology abounds for capturing presentations. However, no simple solution exists that is completely automatic. ProjectorBox is a "zero user interaction" appliance that automatically captures, indexes, and manages presentation multimedia. It operates continuously to record the RGB information sent from presentation devices, such as a presenter's laptop, to display devices, such as a projector. It seamlessly captures high-resolution slide images, text and audio. It requires no operator, specialized software, or changes to current presentation practice. Automatic media analysis is used to detect presentation content and segment presentations. The analysis substantially enhances the web-based user interface for browsing, searching, and exporting captured presentations. ProjectorBox has been in use for over a year in our corporate conference room, and has been deployed in two universities. Our goal is to develop automatic capture services that address both corporate and educational needs.

  16. The quiet revolution: continuous glider monitoring at ocean 'choke' points as a key component of new cross-platform ocean observation systems

    NASA Astrophysics Data System (ADS)

    Heslop, E. E.; Tintore, J.; Ruiz, S.; Allen, J.; López-Jurado, J. L.

    2014-12-01

    A quiet revolution is taking place in ocean observations; in the last decade new multi-platform, integrated ocean observatories have been progressively implemented by forward looking countries with ocean borders of economic and strategic importance. These systems are designed to fill significant gaps in our knowledge of the ocean state and ocean variability, through long-term, science and society-led, ocean monitoring. These ocean observatories are now delivering results, not the headline results of a single issue experiment, but carefully and systematically improving our knowledge of ocean variability, and thereby, increasing model forecast skill and our ability to link physical processes to ecosystem response. Here we present the results from a 3-year quasi-continuous glider monitoring of a key circulation 'choke' point in the Western Mediterranean, undertaken by SOCIB (Balearic Islands Coastal Ocean Observing and Forecasting System). For the first time data from the high frequency glider sampling show variations in the transport volumes of water over timescales of days to weeks, as large as those previously only identifiable as seasonal or eddy driven. Although previous surveys noted high cruise-to-cruise variability, they were insufficient to show that in fact water volumes exchanged through this narrow 'choke' point fluctuate on 'weather' timescales. Using the glider data to leverage an 18-year record of ship missions, we define new seasonal cycles for the exchange of watermasses, challenging generally held assumptions. The pattern of the exchange is further simplified through the characterisation of 5 circulation modes and the defining of a new seasonal cycle for the interplay between mesoscale and basin scale dynamics. Restricted 'choke points' between our ocean basins are critical locations to monitor water transport variability, as they constrain the inter-basin exchange of heat, salt and nutrients. At the Ibiza Channel 'choke' point, the exchange of watermass is known to affect local ecosystems, including the spawning grounds of commercially important fish stocks, at a biodiversity hotspot. This new insight will be vital in improving our ocean model forecast skill and in the development of integrated ocean products for society.

  17. Kinetic buffers.

    PubMed

    Alibrandi, Giuseppe; Fabbrizzi, Luigi; Licchelli, Maurizio; Puglisi, Antonio

    2015-01-12

    This paper proposes a new type of molecular device that is able to act as an inverse proton sponge to slowly decrease the pH inside a reaction vessel. This makes the automatic monitoring of the concentration of pH-sensitive systems possible. The device is a composite formed of an alkyl chloride, which kinetically produces acidity, and a buffer that thermodynamically modulates the variation in pH value. Profiles of pH versus time (pH-t plots) have been generated under various experimental conditions by computer simulation, and the device has been tested by carrying out automatic spectrophotometric titrations, without using an autoburette. To underline the wide variety of possible applications, this new system has been used to realize and monitor HCl uptake by a di-copper(II) bistren complex in a single run, in a completely automatic experiment. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Development of on line automatic separation device for apple and sleeve

    NASA Astrophysics Data System (ADS)

    Xin, Dengke; Ning, Duo; Wang, Kangle; Han, Yuhang

    2018-04-01

    Based on STM32F407 single chip microcomputer as control core, automatic separation device of fruit sleeve is designed. This design consists of hardware and software. In hardware, it includes mechanical tooth separator and three degree of freedom manipulator, as well as industrial control computer, image data acquisition card, end effector and other structures. The software system is based on Visual C++ development environment, to achieve localization and recognition of fruit sleeve with the technology of image processing and machine vision, drive manipulator of foam net sets of capture, transfer, the designated position task. Test shows: The automatic separation device of the fruit sleeve has the advantages of quick response speed and high separation success rate, and can realize separation of the apple and plastic foam sleeve, and lays the foundation for further studying and realizing the application of the enterprise production line.

  19. Unravelling relationships: Hospital occupancy levels, discharge timing and emergency department access block.

    PubMed

    Khanna, Sankalp; Boyle, Justin; Good, Norm; Lind, James

    2012-10-01

    To investigate the effect of hospital occupancy levels on inpatient and ED patient flow parameters, and to simulate the impact of shifting discharge timing on occupancy levels. Retrospective analysis of hospital inpatient data and ED data from 23 reporting public hospitals in Queensland, Australia, across 30 months. Relationships between outcome measures were explored through the aggregation of the historic data into 21 912 hourly intervals. Main outcome measures included admission and discharge rates, occupancy levels, length of stay for admitted and emergency patients, and the occurrence of access block. The impact of shifting discharge timing on occupancy levels was quantified using observed and simulated data. The study identified three stages of system performance decline, or choke points, as hospital occupancy increased. These choke points were found to be dependent on hospital size, and reflect a system change from 'business-as-usual' to 'crisis'. Effecting early discharge of patients was also found to significantly (P < 0.001) impact overcrowding levels and improve patient flow. Modern hospital systems have the ability to operate efficiently above an often-prescribed 85% occupancy level, with optimal levels varying across hospitals of different size. Operating over these optimal levels leads to performance deterioration defined around occupancy choke points. Understanding these choke points and designing strategies around alleviating these flow bottlenecks would improve capacity management, reduce access block and improve patient outcomes. Effecting early discharge also helps alleviate overcrowding and related stress on the system. © 2012 CSIRO. EMA © 2012 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  20. A Case Study of Hypnosis for Phagophobia: It's No Choking Matter.

    PubMed

    Reid, David B

    2016-04-01

    In this case study the author reviews the benefits of hypnosis for a 13-year-old female suffering from a specific phobia involving a fear of choking and generalized fear of swallowing that resulted in an episode of Restrictive Food Intake Disorder with associated significant weight loss. At the time of the initial consultation, three weeks after her choking episode, the patient weighed 93 pounds. Standing at 5'2", her Body Mass Index (BMI) was 17 (15th percentile) indicative of healthy weight for a child her age and height. She continued to lose weight over the course of 2 months and at her worst weighed 85 pounds (BMI = 15.5, 3rd percentile, classified as underweight). Prior to the incident, she weighed 105 pounds with a BMI of 19.2 (46th percentile). Treatment initially consisted of 12 hypnosis sessions (over a 5-month period), conducted on a weekly and eventually biweekly basis. A scheduled one-month follow-up visit was conducted following the 12th session, at which time the patient was consuming solid foods without fear of choking. Her BMI at that time was 18.7 (39th percentile). Two months after terminating treatment, the patient experienced a mild relapse triggered by conflicts with some female peers. After four additional hypnosis sessions, the patient's symptoms again remitted. During her last session we shared a pizza, providing clear and convincing evidence that she had overcome her fear of swallowing. She retained therapeutic benefits for at least 3 years following treatment.

  1. Adjoint-based sensitivity analysis of low-order thermoacoustic networks using a wave-based approach

    NASA Astrophysics Data System (ADS)

    Aguilar, José G.; Magri, Luca; Juniper, Matthew P.

    2017-07-01

    Strict pollutant emission regulations are pushing gas turbine manufacturers to develop devices that operate in lean conditions, with the downside that combustion instabilities are more likely to occur. Methods to predict and control unstable modes inside combustion chambers have been developed in the last decades but, in some cases, they are computationally expensive. Sensitivity analysis aided by adjoint methods provides valuable sensitivity information at a low computational cost. This paper introduces adjoint methods and their application in wave-based low order network models, which are used as industrial tools, to predict and control thermoacoustic oscillations. Two thermoacoustic models of interest are analyzed. First, in the zero Mach number limit, a nonlinear eigenvalue problem is derived, and continuous and discrete adjoint methods are used to obtain the sensitivities of the system to small modifications. Sensitivities to base-state modification and feedback devices are presented. Second, a more general case with non-zero Mach number, a moving flame front and choked outlet, is presented. The influence of the entropy waves on the computed sensitivities is shown.

  2. Improved Automatically Locking/Unlocking Orthotic Knee Joint

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce

    1995-01-01

    Proposed orthotic knee joint improved version of one described in "Automatically Locking/Unlocking Orthotic Knee Joint" (MFS-28633). Locks automatically upon initial application of radial force (wearer's weight) and unlocks automatically, but only when all loads (radial force and bending) relieved. Joints lock whenever wearer applies weight to knee at any joint angle between full extension and 45 degree bend. Both devices offer increased safety and convenience relative to conventional orthotic knee joints.

  3. 77 FR 58170 - Proposed Renewal of Existing Information Collection; Fire Protection (Underground Coal Mines)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-19

    ... the locations of automatic fire warning sensors and the intended air flow direction at these locations...) requires that a qualified person examine the automatic fire sensor and warning device systems on a weekly....1103-8(b) requires that a record of the weekly automatic fire sensor functional tests be maintained by...

  4. Automatic water inventory, collecting, and dispensing unit

    NASA Technical Reports Server (NTRS)

    Hall, J. B., Jr.; Williams, E. F.

    1972-01-01

    Two cylindrical tanks with piston bladders and associated components for automatic filling and emptying use liquid inventory readout devices in control of water flow. Unit provides for adaptive water collection, storage, and dispensation in weightlessness environment.

  5. Regulatory Considerations for Physiological Closed-Loop Controlled Medical Devices Used for Automated Critical Care: Food and Drug Administration Workshop Discussion Topics.

    PubMed

    Parvinian, Bahram; Scully, Christopher; Wiyor, Hanniebey; Kumar, Allison; Weininger, Sandy

    2018-06-01

    Part of the mission of the Center for Devices and Radiological Health (CDRH) at the US Food and Drug Administration is to facilitate medical device innovation. Therefore, CDRH plays an important role in helping its stakeholders such as manufacturers, health care professionals, patients, patient advocates, academia, and other government agencies navigate the regulatory landscape for medical devices. This is particularly important for innovative physiological closed-loop controlled (PCLC) devices used in critical care environments, such as intensive care units, emergency settings, and battlefield environments. CDRH's current working definition of a PCLC medical device is a medical device that incorporates physiological sensor(s) for automatic manipulation of a physiological variable through actuation of therapy that is conventionally made by a clinician. These emerging devices enable automatic therapy delivery and may have the potential to revolutionize the standard of care by ensuring adequate and timely therapy delivery with improved performance in high workload and high-stress environments. For emergency response and military applications, automatic PCLC devices may play an important role in reducing cognitive overload, minimizing human error, and enhancing medical care during surge scenarios (ie, events that exceed the capability of the normal medical infrastructure). CDRH held an open public workshop on October 13 and 14, 2015 with the aim of fostering an open discussion on design, implementation, and evaluation considerations associated with PCLC devices used in critical care environments. CDRH is currently developing regulatory recommendations and guidelines that will facilitate innovation for PCLC devices. This article highlights the contents of the white paper that was central to the workshop and focuses on the ensuing discussions regarding the engineering, clinical, and human factors considerations.

  6. [Electronic Device for Retinal and Iris Imaging].

    PubMed

    Drahanský, M; Kolář, R; Mňuk, T

    This paper describes design and construction of a new device for automatic capturing of eye retina and iris. This device has two possible ways of utilization - either for biometric purposes (persons recognition on the base of their eye characteristics) or for medical purposes as supporting diagnostic device. eye retina, eye iris, device, acquisition, image.

  7. 21 CFR 801.40 - Form of a unique device identifier.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) Automatic identification and data capture (AIDC) technology. (b) The UDI must include a device identifier... evident upon visual examination of the label or device package, the label or device package must disclose... label and device packages is deemed to meet all requirements of subpart B of this part. The UPC will...

  8. Variable-speed controller provides flexibility to electrical submersible pumps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butlin, D.

    1986-06-09

    The performance of an electric submersible pump (ESP) is dramatically modified by a variable speed controller (VSC). Variable frequency power directly controls pump speed and thus the hydraulic performance of the pump. Even though the ESP is the primary form of artificial lift for high volume, deep oil wells (particularly where gas is unavailable), the biggest disadvantage has been the pump's inflexibility when run at a constant speed, i.e., the unit is limited to a fixed head output at each rate. The VSC has rapidly gained acceptance as a valuable ESP accessory to alleviate this restriction. By allowing the pumpmore » speed to be varied, the rate and head, or both, can be adjusted with no modification of the downhole unit. There are now over 700 VSCs running with ESPs on every continent of the world. Pumping flexibility was the main purpose of applying the VSC to the ESP, but several other benefits have become apparent. Of particular interest are those that can extend downhole equipment life, e.g., soft start, automatically controlled speed, line-transient suppression, and elimination of surface chokes.« less

  9. 7 CFR 58.227 - Sampling device.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Sampling device. 58.227 Section 58.227 Agriculture....227 Sampling device. If automatic sampling devices are used, they shall be constructed in such a.... The type of sampler and the sampling procedure shall be as approved by the Administrator. ...

  10. 7 CFR 58.227 - Sampling device.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Sampling device. 58.227 Section 58.227 Agriculture....227 Sampling device. If automatic sampling devices are used, they shall be constructed in such a.... The type of sampler and the sampling procedure shall be as approved by the Administrator. ...

  11. The application of charge-coupled device processors in automatic-control systems

    NASA Technical Reports Server (NTRS)

    Mcvey, E. S.; Parrish, E. A., Jr.

    1977-01-01

    The application of charge-coupled device (CCD) processors to automatic-control systems is suggested. CCD processors are a new form of semiconductor component with the unique ability to process sampled signals on an analog basis. Specific implementations of controllers are suggested for linear time-invariant, time-varying, and nonlinear systems. Typical processing time should be only a few microseconds. This form of technology may become competitive with microprocessors and minicomputers in addition to supplementing them.

  12. Unusual case of choking due to assassin bug ( Cydnocoris gilvus).

    PubMed

    Sonar, Vaibhav; Patil, Sachin

    2018-01-01

    Choking is a form of asphyxia which is caused by an obstruction within the air passages. Here, we report a case of obstruction of the upper respiratory tract due to assassin bug ( Cydnocoris gilvus) where allegations of medical negligence were made by relatives of the deceased. Autopsy findings demonstrated that an insect was present inside the larynx, lodged at the epiglottis. Multiple haemorrhagic patches were present at the base of the tongue, larynx, epiglottis, vocal cords and tracheal bifurcation. As Reduviidae can be successfully used as a biological pest-control agents, they should be used with due precaution.

  13. Intensification and refraction of acoustical signals in partially choked converging ducts

    NASA Technical Reports Server (NTRS)

    Nayfeh, A. H.

    1980-01-01

    A computer code based on the wave-envelope technique is used to perform detailed numerical calculations for the intensification and refraction of sound in converging hard walled and lined circular ducts carrying high mean Mach number flows. The results show that converging ducts produce substantial refractions toward the duct center for waves propagating against near choked flows. As expected, the magnitude of the refraction decreases as the real part of the admittance increases. The pressure wave pattern is that of interference among the different modes, and hence the variation of the magnitude of pressure refraction with frequency is not monotonic.

  14. Measurements of Thermal Effects on Acoustic Screech in a Choked Circular Jet Emanating from a Sharp-Edged Orifice

    NASA Technical Reports Server (NTRS)

    Kandula, Max

    2012-01-01

    Experiments are performed in a 24.4 mm diameter choked circular hot and cold jets issuing from a sharp-edged orifice at a fully expanded jet Mach number of 1.85. The stagnation temperature of the hot and the cold jets are 319 K and 299 K respectively. The results suggest that temperature effects on the screech amplitude and frequency are manifested for the fundamental, with a reduced amplitude and increased frequency for hot jet relative to the cold jet. Temperature effects on the second harmonic are also observed.

  15. Correlation of Gastroesophageal reflux disease Assessment Symptom Questionnaire to impedance-pH measurements in children.

    PubMed

    Prachuapthunyachart, Sittichoke; Jarasvaraparn, Chaowapong; Gremse, David A

    2017-01-01

    Esophageal multichannel intraluminal impedance-pH monitoring has become one of the preferred tests to correlate observed reflux-like behaviors with esophageal reflux events. The Gastroesophageal reflux disease Assessment Symptom Questionnaire is a validated tool used to distinguish infants with gastroesophageal reflux disease from healthy children. The aim of this study was to determine whether the Gastroesophageal reflux disease Assessment Symptom Questionnaire composite symptom scores and individual symptom scores correlate with outcomes in esophageal multichannel intraluminal impedance-pH monitoring. A total of 26 patients with gastroesophageal reflux disease-associated symptoms, aged 0-2 years, for whom both esophageal multichannel intraluminal impedance-pH monitoring and Gastroesophageal reflux disease Assessment Symptom Questionnaire survey results were available were included in the study. Gastroesophageal reflux disease Assessment Symptom Questionnaire score data were collected from a 7-day recall of parent's responses about the frequency and severity of gastroesophageal reflux disease symptoms, which determined the individual symptom scores. The composite symptom scores is the sum of all individual symptom scores. Multichannel intraluminal impedance-pH study results were compared to Gastroesophageal reflux disease Assessment Symptom Questionnaire data using Pearson correlation. Among 26 patients, a total number of 2817 (1700 acid and 1117 non-acid) reflux episodes and 845 clinical reflux behaviors were recorded. There were significant correlations between the reflux index and the individual symptom scores for coughing/gagging/choking (r 2 = 0.2842, p = 0.005), the impedance score and individual symptom scores for coughing/gagging/choking (r 2 = 0.2482, p = 0.009), the reflux symptom index for acid reflux-related coughing/gagging/choking and the individual symptom scores for coughing/gagging/choking (r 2 = 0.1900, p = 0.026), the impedance score and individual symptom scores for vomiting (r 2 = 0.1569, p = 0.045), and the impedance score and the composite symptom scores (r 2 = 0.2916, p = 0.004). However, there were no significant correlations between fussiness, irritability, or abdominal pain-related multichannel intraluminal impedance-pH results and the individual symptom scores for abdominal pain. The impedance scores from multichannel intraluminal impedance-pH studies correlate with coughing/gagging/choking and vomiting in infants with gastroesophageal reflux disease. There are no significant correlations among the reflux index and impedance score versus the Gastroesophageal reflux disease Assessment Symptom Questionnaire scores for abdominal pain. We conclude that in infants with gastroesophageal reflux disease, multichannel intraluminal impedance-pH studies are more likely to demonstrate an association between gastroesophageal reflux disease and symptoms of coughing, gagging, or choking compared to an association between gastroesophageal reflux disease and pain in infants.

  16. Correlation of Gastroesophageal reflux disease Assessment Symptom Questionnaire to impedance-pH measurements in children

    PubMed Central

    Prachuapthunyachart, Sittichoke; Jarasvaraparn, Chaowapong; Gremse, David A

    2017-01-01

    Background: Esophageal multichannel intraluminal impedance-pH monitoring has become one of the preferred tests to correlate observed reflux-like behaviors with esophageal reflux events. The Gastroesophageal reflux disease Assessment Symptom Questionnaire is a validated tool used to distinguish infants with gastroesophageal reflux disease from healthy children. The aim of this study was to determine whether the Gastroesophageal reflux disease Assessment Symptom Questionnaire composite symptom scores and individual symptom scores correlate with outcomes in esophageal multichannel intraluminal impedance-pH monitoring. Methods: A total of 26 patients with gastroesophageal reflux disease–associated symptoms, aged 0–2 years, for whom both esophageal multichannel intraluminal impedance-pH monitoring and Gastroesophageal reflux disease Assessment Symptom Questionnaire survey results were available were included in the study. Gastroesophageal reflux disease Assessment Symptom Questionnaire score data were collected from a 7-day recall of parent’s responses about the frequency and severity of gastroesophageal reflux disease symptoms, which determined the individual symptom scores. The composite symptom scores is the sum of all individual symptom scores. Multichannel intraluminal impedance-pH study results were compared to Gastroesophageal reflux disease Assessment Symptom Questionnaire data using Pearson correlation. Results: Among 26 patients, a total number of 2817 (1700 acid and 1117 non-acid) reflux episodes and 845 clinical reflux behaviors were recorded. There were significant correlations between the reflux index and the individual symptom scores for coughing/gagging/choking (r2 = 0.2842, p = 0.005), the impedance score and individual symptom scores for coughing/gagging/choking (r2 = 0.2482, p = 0.009), the reflux symptom index for acid reflux-related coughing/gagging/choking and the individual symptom scores for coughing/gagging/choking (r2 = 0.1900, p = 0.026), the impedance score and individual symptom scores for vomiting (r2 = 0.1569, p = 0.045), and the impedance score and the composite symptom scores (r2 = 0.2916, p = 0.004). However, there were no significant correlations between fussiness, irritability, or abdominal pain–related multichannel intraluminal impedance-pH results and the individual symptom scores for abdominal pain. Conclusion: The impedance scores from multichannel intraluminal impedance-pH studies correlate with coughing/gagging/choking and vomiting in infants with gastroesophageal reflux disease. There are no significant correlations among the reflux index and impedance score versus the Gastroesophageal reflux disease Assessment Symptom Questionnaire scores for abdominal pain. We conclude that in infants with gastroesophageal reflux disease, multichannel intraluminal impedance-pH studies are more likely to demonstrate an association between gastroesophageal reflux disease and symptoms of coughing, gagging, or choking compared to an association between gastroesophageal reflux disease and pain in infants. PMID:29276590

  17. Automatic multiple applicator electrophoresis

    NASA Technical Reports Server (NTRS)

    Grunbaum, B. W.

    1977-01-01

    Easy-to-use, economical device permits electrophoresis on all known supporting media. System includes automatic multiple-sample applicator, sample holder, and electrophoresis apparatus. System has potential applicability to fields of taxonomy, immunology, and genetics. Apparatus is also used for electrofocusing.

  18. A Versatile, Automatic Chromatographic Column Packing Device

    ERIC Educational Resources Information Center

    Barry, Eugene F.; And Others

    1977-01-01

    Describes an inexpensive apparatus for packing liquid and gas chromatographic columns of high efficiency. Consists of stainless steel support struts, an Automat Getriebmotor, and an associated three-pulley system capable of 10, 30, and 300 rpm. (MLH)

  19. New weight-handling device for commercial oil pressure balances

    NASA Astrophysics Data System (ADS)

    Woo, S. Y.; Choi, I. M.; Kim, B. S.

    2005-12-01

    This paper presents a new device to automatically handle a large number of weights for the calibration of a pressure gauge. This newly invented weight-handling device is made for use in conjunction with a commercial oil pressure balance. Although the pressure balance is essential as a calibration tool, its use has been generally tedious and labour intensive for a long time. In particular, the process of loading a different combination of weights on the top of a piston requires repetitious manual handling for every new measurement. This inevitably leaves the operator fatigued, and sometimes causes damage to the weights due to careless handling. The newly invented automatic weight-handling device can eliminate such tedious, error-prone and wear-inducing manual weight manipulation. The device consists of a stepping motor, a drive belt, a solenoid valve, three weight-lifting assemblies and three linear-motion guide assemblies. The weight-lifting assembly is composed of a pneumatic actuator, a solid-state switch and a metal finger. It has many advantages compared with the commercial automatic weight-handling device. Firstly, it is not necessary to lift all the weights off the piston in the weight selection process, as it is in the case of the commercial device. Thus it can prevent a permanent deformation of the weight carrier. Secondly, this new device can handle a larger number of weights than the commercial one. This is because the new device adopts a different method in retaining the remaining weights in place. Another advantage of this new device is that there is no possibility of the fingers touching the surface of the weights due to the oscillation of weights. Moreover it uses the general technology of a stepping motor, and is also made up of components that are easily obtainable in the market, thereby being very economical.

  20. A Quantitative and Qualitative Evaluation of an Automatic Occlusion Device for Tracheoesophageal Speech: The Provox FreeHands HME

    ERIC Educational Resources Information Center

    Hamade, Rachel; Hewlett, Nigel; Scanlon, Emer

    2006-01-01

    This study aimed to evaluate a new automatic tracheostoma valve: the Provox FreeHands HME (manufactured by Atos Medical AB, Sweden). Data from four laryngectomee participants using automatic and also manual occlusion were subjected to acoustic and perceptual analysis. The main results were a significant decrease, from the manual to automatic…

  1. Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Guo, Wan-Gang; Li, Bing-Ling; He, Yong; Xue, Yu-Sheng; Wang, Hai-Yan; Zheng, Qiang-Sun; Xiang, Ding-Cheng

    2014-08-01

    To validate the Andon KD-5917 automatic upper arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Sequential same-left-arm measurements of systolic blood pressure (SBP) and diastolic blood pressure (DBP) were obtained in 33 participants using the mercury sphygmomanometer and the test device. According to the validation protocol, 99 pairs of test device and reference blood pressure measurements (three pairs for each of the 33 participants) were obtained in the study. The device produced 73, 98, and 99 measurements within 5, 10, and 15 mmHg for SBP and 86, 98, and 99 for DBP, respectively. The mean ± SD device-observer difference was 3.07 ± 3.68 mmHg for SBP and -0.89 ± 3.72 mmHg for DBP. The number of patients with two or three of the device-observer difference within 5 mmHg was 26 for SBP and 29 for DBP, and no patient had a device-observer difference within 5 mmHg. The Andon KD-5917 automatic upper arm blood pressure monitor can be recommended for clinical use and self-measurement in an adult population on the basis of the European Society of Hypertension International Protocol revision 2010.

  2. A Full Automatic Device for Sampling Small Solution Volumes in Photometric Titration Procedure Based on Multicommuted Flow System

    PubMed Central

    Borges, Sivanildo S.; Vieira, Gláucia P.; Reis, Boaventura F.

    2007-01-01

    In this work, an automatic device to deliver titrant solution into a titration chamber with the ability to determine the dispensed volume of solution, with good precision independent of both elapsed time and flow rate, is proposed. A glass tube maintained at the vertical position was employed as a container for the titrant solution. Electronic devices were coupled to the glass tube in order to control its filling with titrant solution, as well as the stepwise solution delivering into the titration chamber. The detection of the titration end point was performed employing a photometer designed using a green LED (λ=545 nm) and a phototransistor. The titration flow system comprised three-way solenoid valves, which were assembled to allow that the steps comprising the solution container loading and the titration run were carried out automatically. The device for the solution volume determination was designed employing an infrared LED (λ=930 nm) and a photodiode. When solution volume delivered from proposed device was within the range of 5 to 105 μl, a linear relationship (R = 0.999) between the delivered volumes and the generated potential difference was achieved. The usefulness of the proposed device was proved performing photometric titration of hydrochloric acid solution with a standardized sodium hydroxide solution and using phenolphthalein as an external indicator. The achieved results presented relative standard deviation of 1.5%. PMID:18317510

  3. Solving gas-processing problems. Part 8. Expansion processes, turboexpander efficiency vital for predicting liquid-recovery levels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erbar, J.H.; Maddox, R.N.

    1981-07-06

    Expansion processes, using either Joule-Thomson or isentropic principles play an important role in the processing of natural gas streams for liquid recovery and/or hydrocarbon-dewpoint control. Constant-enthalpy expansion has been an integral part of gas processing schemes for many years. The constant entropy, or isentropic, process is more recent but has achieved wide-spread popularity. In typcial flow sheets for expansion processess, the expansion device is shown to be a value or choke. It also could be an expansion turbine to indicate an isentropic expansion. The expansion may be to lower pressure; or, in the case of turboexpansion, it could recover materialmore » or produce work. More frequently, the aim of the expansion is to produce low temperature and enhance liquid recovery.« less

  4. The clinical benefit of cardiac resynchronization therapy optimization using a device-based hemodynamic sensor in a patient with dilated cardiomyopathy: a case report.

    PubMed

    Volpicelli, Mario; Covino, Gregorio; Capogrosso, Paolo

    2015-12-19

    Results on the evolution of the clinical status of patients undergoing cardiac resynchronization therapy with a defibrillator after automatic optimization of their cardiac resynchronization therapy are scarce. We observed a rapid and important change in the clinical status of our non-responding patient following activation of a sensor capable of weekly atrioventricular and interventricular delays' optimization. A 78-year-old Caucasian man presented with dilated cardiomyopathy, left bundle branch block, a left ventricular ejection fraction of 35 %, New York Heart Association class III/IV heart failure, and paroxysmal atrial fibrillation. Our patient was implanted with a cardiac resynchronization device with a defibrillator and the SonRtip atrial lead. Right ventricular and left ventricular leads were also implanted. Because of the recurrence of atrial fibrillation, the automatic optimization was set off at discharge. Consequently, the device did not optimize atrioventricular and interventricular delays (programming at discharge: 125 ms for the atrioventricular delay and 0 ms for the interventriculardelay). Our patient was treated with an anti-arrhythmic drug. Five months after implantation, his clinical status remained impaired (left ventricular ejection fraction = 30 %). The SonR signal amplitude had also decreased from 0.52 g to 0.29 g. Nevertheless, because our patient was no longer presenting with atrial fibrillation, the anti-arrhythmic treatment was stopped and the SonR optimization system was activated. After 2 months of automatic cardiac resynchronization therapy with defibrillator optimization, our patient's clinical status had significantly improved (left ventricular ejection fraction = 60 %, New York Heart Association class II) and the SonR signal amplitude had doubled shortly after the first weekly automatic optimization. In this non-responding patient, device-based automatic cardiac resynchronization therapy optimization was shown to significantly improve his clinical status.

  5. Automatic Adviser on stationary devices status identification and anticipated change

    NASA Astrophysics Data System (ADS)

    Shabelnikov, A. N.; Liabakh, N. N.; Gibner, Ya M.; Pushkarev, E. A.

    2018-05-01

    A task is defined to synthesize an Automatic Adviser to identify the automation systems stationary devices status using an autoregressive model of changing their key parameters. An applied model type was rationalized and the research objects monitoring process algorithm was developed. A complex of mobile objects status operation simulation and prediction results analysis was proposed. Research results are commented using a specific example of a hump yard compressor station. The work was supported by the Russian Fundamental Research Fund, project No. 17-20-01040.

  6. Command, Control, Communications, Computers and Intelligence Electronic Warfare (C4IEW) Project Book, Fiscal Year 1994. (Non-FOUO Version)

    DTIC Science & Technology

    1994-04-01

    TSW-7A, AIR TRAFFIC CONTROL CENTRAL (ATCC) 32- 8 AN/TTC-41(V), CENTRAL OFFICE, TELEPHONE, AUTOMATIC 32- 9 MISSILE COUNTERMEASURE DEVICE (MCD) .- 0 MK...a Handheld Terminal Unit (HTU), Portable Computer Unit (PCU), Transportable Computer Unit (TCU), and compatible NOI peripheral devices . All but the...CLASSIFICATION: ASARC-III, Jun 80, Standard. I I I AN/TIC-39 IS A MOBILE , AUTOMATIC , MODULAR ELECTRONIC CIRCUIT SWITCH UNDER PROCESSOR CONTROL WITH INTEGRAL

  7. A closed-form analytical model for predicting 3D boundary layer displacement thickness for the validation of viscous flow solvers

    NASA Astrophysics Data System (ADS)

    Kumar, V. R. Sanal; Sankar, Vigneshwaran; Chandrasekaran, Nichith; Saravanan, Vignesh; Natarajan, Vishnu; Padmanabhan, Sathyan; Sukumaran, Ajith; Mani, Sivabalan; Rameshkumar, Tharikaa; Nagaraju Doddi, Hema Sai; Vysaprasad, Krithika; Sharan, Sharad; Murugesh, Pavithra; Shankar, S. Ganesh; Nejaamtheen, Mohammed Niyasdeen; Baskaran, Roshan Vignesh; Rahman Mohamed Rafic, Sulthan Ariff; Harisrinivasan, Ukeshkumar; Srinivasan, Vivek

    2018-02-01

    A closed-form analytical model is developed for estimating the 3D boundary-layer-displacement thickness of an internal flow system at the Sanal flow choking condition for adiabatic flows obeying the physics of compressible viscous fluids. At this unique condition the boundary-layer blockage induced fluid-throat choking and the adiabatic wall-friction persuaded flow choking occur at a single sonic-fluid-throat location. The beauty and novelty of this model is that without missing the flow physics we could predict the exact boundary-layer blockage of both 2D and 3D cases at the sonic-fluid-throat from the known values of the inlet Mach number, the adiabatic index of the gas and the inlet port diameter of the internal flow system. We found that the 3D blockage factor is 47.33 % lower than the 2D blockage factor with air as the working fluid. We concluded that the exact prediction of the boundary-layer-displacement thickness at the sonic-fluid-throat provides a means to correctly pinpoint the causes of errors of the viscous flow solvers. The methodology presented herein with state-of-the-art will play pivotal roles in future physical and biological sciences for a credible verification, calibration and validation of various viscous flow solvers for high-fidelity 2D/3D numerical simulations of real-world flows. Furthermore, our closed-form analytical model will be useful for the solid and hybrid rocket designers for the grain-port-geometry optimization of new generation single-stage-to-orbit dual-thrust-motors with the highest promising propellant loading density within the given envelope without manifestation of the Sanal flow choking leading to possible shock waves causing catastrophic failures.

  8. Approaches to the automatic generation and control of finite element meshes

    NASA Technical Reports Server (NTRS)

    Shephard, Mark S.

    1987-01-01

    The algorithmic approaches being taken to the development of finite element mesh generators capable of automatically discretizing general domains without the need for user intervention are discussed. It is demonstrated that because of the modeling demands placed on a automatic mesh generator, all the approaches taken to date produce unstructured meshes. Consideration is also given to both a priori and a posteriori mesh control devices for automatic mesh generators as well as their integration with geometric modeling and adaptive analysis procedures.

  9. A microfluidic-based lid device for conventional cell culture dishes to automatically control oxygen level.

    PubMed

    Lee, Seung Yeob; Yang, Sung

    2018-04-25

    Most conventional hypoxic cell culture systems undergo reoxygenation during experimental manipulations, resulting in undesirable effects including the reduction of cell viability. A lid device was developed herein for conventional cell culture dishes to resolve this limitation. The integration of multilayered microfluidic channels inside a thin membrane was designed to prevent the reoxygenation caused by reagent infusion and automatically control the oxygen level. The experimental data clearly show the reducibility of the dissolved oxygen in the infusing reagent and the controllability of the oxygen level inside the dish. The feasibility of the device for hypoxia studies was confirmed by HIF-1α experiments. Therefore, the device could be used as a compact and convenient hypoxic cell culture system to prevent reoxygenation-related issues.

  10. Spill-Detector-and-Shutoff Device

    NASA Technical Reports Server (NTRS)

    Jarvis, M. R.; Fulton, D. S.

    1985-01-01

    Overflow in liquid chromatography systems rapidly detected and stopped. Spill-detector-and-shutoff device incorporated into liquid-chromatography system. When liquid from output nozzle spills on liquid sensor, device automatically shuts off pump and releases solenoid to pinch off flow in tube. Device uses common type of alarm circuit reset manually before normal operation resumes.

  11. Eye-tracking for clinical decision support: A method to capture automatically what physicians are viewing in the EMR

    PubMed Central

    King, Andrew J.; Hochheiser, Harry; Visweswaran, Shyam; Clermont, Gilles; Cooper, Gregory F.

    2017-01-01

    Eye-tracking is a valuable research tool that is used in laboratory and limited field environments. We take steps toward developing methods that enable widespread adoption of eye-tracking and its real-time application in clinical decision support. Eye-tracking will enhance awareness and enable intelligent views, more precise alerts, and other forms of decision support in the Electronic Medical Record (EMR). We evaluated a low-cost eye-tracking device and found the device’s accuracy to be non-inferior to a more expensive device. We also developed and evaluated an automatic method for mapping eye-tracking data to interface elements in the EMR (e.g., a displayed laboratory test value). Mapping was 88% accurate across the six participants in our experiment. Finally, we piloted the use of the low-cost device and the automatic mapping method to label training data for a Learning EMR (LEMR) which is a system that highlights the EMR elements a physician is predicted to use. PMID:28815151

  12. Self-actuating heat switches for redundant refrigeration systems

    NASA Technical Reports Server (NTRS)

    Chan, Chung K. (Inventor)

    1988-01-01

    A dual refrigeration system for cooling a sink device is described, which automatically thermally couples the cold refrigerator to the sink device while thermally isolating the warm refrigerator from the sink device. The system includes two gas gap heat switches that each thermally couples one of the refrigerators to the sink device, and a pair of sorption pumps that are coupled through tubes to the heat switches. When the first refrigerator is operated and therefore cold, the first pump which is thermally coupled to it is also cooled and adsorbs gas to withdraw it from the second heat switch, to thereby thermally isolate the sink device from the warm second refrigerator. With the second refrigerator being warm, the second pump is also warm and desorbs gas, so the gas lies in the first switch, to close that switch and therefore thermally couple the cold first refrigerator to the sink device. Thus, the heat switches are automatically switched according to the temperature of the corresponding refrigerator.

  13. Powder fed sheared dispersal particle generator

    NASA Technical Reports Server (NTRS)

    Morrisette, E. L.; Bushnell, D. M. (Inventor)

    1984-01-01

    A particle generating system is described which is capable of breaking up agglomerations of particles and producing a cloud of uniform, submicron-sized particles at high pressure and high flow rates. This is achieved by utilizing a tubular structure which has injection microslits on is periphery to accept and disperse the desired particle feed. By suppling a carrying fluid at a pressure, of approximately twice the ambient pressure of the velocimeter's settling chamber, the microslits operate at choked flow conditions. The shearing action of this choked flow is sufficient to overcome interparticle bonding forces, thereby breaking up the agglomerates of the particles feed into individual particles.

  14. Exploring the Properties of Choked Gamma-ray Bursts with IceCube’s High-energy Neutrinos

    NASA Astrophysics Data System (ADS)

    Denton, Peter B.; Tamborra, Irene

    2018-03-01

    Long duration gamma-ray bursts (GRBs) have often been considered the natural evolution of some core-collapse supernova (CCSN) progenitors. However, the fraction of CCSNe linked to astrophysical jets and their properties are still poorly constrained. While any successful astrophysical jet harbored in a CCSN should produce high-energy neutrinos, photons may be able to successfully escape the stellar envelope only for a fraction of progenitors, possibly leading to the existence of high-luminosity, low-luminosity, and not-electromagnetically bright (“choked”) GRBs. By postulating a CCSN–GRB connection, we accurately model the jet physics within the internal-shock GRB model and assume scaling relations for the GRB parameters that depend on the Lorentz boost factor Γ. The IceCube high-energy neutrino flux is then employed as an upper limit of the neutrino background from electromagnetically bright and choked GRBs to constrain the jet and the progenitor properties. The current IceCube data set is compatible with up to 1% of all CCSNe harboring astrophysical jets. Interestingly, those jets are predominantly choked. Our findings suggest that neutrinos can be powerful probes of the burst physics and can provide major insights on the CCSN–GRB connection.

  15. Why do English players fail in soccer penalty shootouts? A study of team status, self-regulation, and choking under pressure.

    PubMed

    Jordet, Geir

    2009-01-15

    I examine why players from some nations appear always to choke in major international soccer penalty shootouts. Based on a model on choking under pressure as a type of self-defeating behaviour (Baumeister, 1997), I hypothesized that highly favourable public appraisals of a team would be linked to displays of escapist self-regulation strategies and inferior performance. I selected the eight most merited European nations, obtained videos from penalty shootouts in two major international tournaments (World Cup and European Championships), and analysed all 200 shots taken by players representing these teams. The results showed significant relationships between team status, self-regulation strategies, and performance. Players from countries that, at the time of the penalty shootout, either had many international club titles or featured many internationally decorated players, spent less time preparing their shots and were less successful from the penalty spot than players from countries with lower public status. England and Spain are used to illustrate these effects, as the data suggest that players from these two countries may have underperformed in previous international soccer tournaments because of high public status and misguided self-regulation strategies.

  16. Stability limits of unsteady open capillary channel flow

    NASA Astrophysics Data System (ADS)

    Grah, Aleksander; Haake, Dennis; Rosendahl, Uwe; Klatte, J.?Rg; Dreyer, Michael E.

    This paper is concerned with steady and unsteady flow rate limitations in open capillary channels under low-gravity conditions. Capillary channels are widely used in Space technology for liquid transportation and positioning, e.g. in fuel tanks and life support systems. The channel observed in this work consists of two parallel plates bounded by free liquid surfaces along the open sides. The capillary forces of the free surfaces prevent leaking of the liquid and gas ingestion into the flow.In the case of steady stable flow the capillary pressure balances the differential pressure between the liquid and the surrounding constant-pressure gas phase. Increasing the flow rate in small steps causes a decrease of the liquid pressure. A maximum steady flow rate is achieved when the flow rate exceeds a certain limit leading to a collapse of the free surfaces due to the choking effect. In the case of unsteady flow additional dynamic effects take place due to flow rate transition and liquid acceleration. The maximum flow rate is smaller than in the case of steady flow. On the other hand, the choking effect does not necessarily cause surface collapse and stable temporarily choked flow is possible under certain circumstances.To determine the limiting volumetric flow rate and stable flow dynamic properties, a new stability theory for both steady and unsteady flow is introduced. Subcritical and supercritical (choked) flow regimes are defined. Stability criteria are formulated for each flow type. The steady (subcritical) criterion corresponds to the speed index defined by the limiting longitudinal small-amplitude wave speed, similar to the Mach number. The unsteady (supercritical) criterion for choked flow is defined by a new characteristic number, the dynamic index. It is based on pressure balances and reaches unity at the stability limit.The unsteady model based on the Bernoulli equation and the mass balance equation is solved numerically for perfectly wetting incompressible liquids. The unsteady model and the stability theory are verified by comparison to results of a sounding rocket experiment (TEXUS 41) on capillary channel flows launched in December 2005 from ESRANGE in north Sweden. For a clear overview of subcritical, supercritical, and unstable flow, parametric studies and stability diagrams are shown and compared to experimental observations.

  17. Techniques for detumbling a disabled space base

    NASA Technical Reports Server (NTRS)

    Kaplan, M. H.

    1973-01-01

    Techniques and conceptual devices for carrying out detumbling operations are examined, and progress in the development of these concepts is discussed. Devices which reduce tumble to simple spin through active linear motion of a small mass are described, together with a Module for Automatic Dock and Detumble (MADD) that could perform an orbital transfer from the shuttle in order to track and dock at a preselected point on the distressed craft. Once docked, MADD could apply torques by firing thrustors to detumble the passive vehicle. Optimum combinations of mass-motion and external devices for various situation should be developed. The need for completely formulating the automatic control logic of MADD is also emphasized.

  18. High-powered automatic latching device

    NASA Technical Reports Server (NTRS)

    Cobin, J. C.; Rhodes, L. L.

    1970-01-01

    Latches automatically lock together two remotely controlled bodies when their triggers are engaged by the docking ring of the lesser body. Latches are disengaged by manual actuation of the handle of each latch through two complete cycles. Emergency locking by manual actuation is also provided.

  19. Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model

    PubMed Central

    2012-01-01

    Background Ultrasonic scalpel (UC) and monopolar electrocautery (ME) are common tools for soft tissue dissection. However, morphological data on the related tissue alteration are discordant. We developed an automatic device for standardized sample excision and compared quality and depth of morphological changes caused by UC and ME in a pig model. Methods 100 tissue samples (5 × 3 cm) of the abdominal wall were excised in 16 pigs. Excisions were randomly performed manually or by using the self-constructed automatic device at standard power levels (60 W cutting in ME, level 5 in UC) for abdominal surgery. Quality of tissue alteration and depth of coagulation necrosis were examined histopathologically. Device (UC vs. ME) and mode (manually vs. automatic) effects were studied by two-way analysis of variance at a significance level of 5%. Results At the investigated power level settings UC and ME induced qualitatively similar coagulation necroses. Mean depth of necrosis was 450.4 ± 457.8 μm for manual UC and 553.5 ± 326.9 μm for automatic UC versus 149.0 ± 74.3 μm for manual ME and 257.6 ± 119.4 μm for automatic ME. Coagulation necrosis was significantly deeper (p < 0.01) when UC was used compared to ME. The mode of excision (manual versus automatic) did not influence the depth of necrosis (p = 0.85). There was no significant interaction between dissection tool and mode of excision (p = 0.93). Conclusions Thermal injury caused by UC and ME results in qualitatively similar coagulation necrosis. The depth of necrosis is significantly greater in UC compared to ME at investigated standard power levels. PMID:22361346

  20. Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model.

    PubMed

    Homayounfar, Kia; Meis, Johanna; Jung, Klaus; Klosterhalfen, Bernd; Sprenger, Thilo; Conradi, Lena-Christin; Langer, Claus; Becker, Heinz

    2012-02-23

    Ultrasonic scalpel (UC) and monopolar electrocautery (ME) are common tools for soft tissue dissection. However, morphological data on the related tissue alteration are discordant. We developed an automatic device for standardized sample excision and compared quality and depth of morphological changes caused by UC and ME in a pig model. 100 tissue samples (5 × 3 cm) of the abdominal wall were excised in 16 pigs. Excisions were randomly performed manually or by using the self-constructed automatic device at standard power levels (60 W cutting in ME, level 5 in UC) for abdominal surgery. Quality of tissue alteration and depth of coagulation necrosis were examined histopathologically. Device (UC vs. ME) and mode (manually vs. automatic) effects were studied by two-way analysis of variance at a significance level of 5%. At the investigated power level settings UC and ME induced qualitatively similar coagulation necroses. Mean depth of necrosis was 450.4 ± 457.8 μm for manual UC and 553.5 ± 326.9 μm for automatic UC versus 149.0 ± 74.3 μm for manual ME and 257.6 ± 119.4 μm for automatic ME. Coagulation necrosis was significantly deeper (p < 0.01) when UC was used compared to ME. The mode of excision (manual versus automatic) did not influence the depth of necrosis (p = 0.85). There was no significant interaction between dissection tool and mode of excision (p = 0.93). Thermal injury caused by UC and ME results in qualitatively similar coagulation necrosis. The depth of necrosis is significantly greater in UC compared to ME at investigated standard power levels.

  1. Automatic control of tracheal tube cuff pressure in ventilated patients in semirecumbent position: a randomized trial.

    PubMed

    Valencia, Mauricio; Ferrer, Miquel; Farre, Ramon; Navajas, Daniel; Badia, Joan Ramon; Nicolas, Josep Maria; Torres, Antoni

    2007-06-01

    The aspiration of subglottic secretions colonized by bacteria pooled around the tracheal tube cuff due to inadvertent deflation (<20 cm H2O) of the cuff plays a relevant role in the pathogenesis of ventilator-associated pneumonia. We assessed the efficacy of an automatic, validated device for the continuous regulation of tracheal tube cuff pressure in preventing ventilator-associated pneumonia. Prospective randomized controlled trial. Respiratory intensive care unit and general medical intensive care unit. One hundred and forty-two mechanically ventilated patients (age, 64 +/- 17 yrs; Acute Physiology and Chronic Health Evaluation II score, 18 +/- 6) without pneumonia or aspiration at admission. Within 24 hrs of intubation, patients were randomly allocated to undergo continuous regulation of the cuff pressure with the automatic device (n = 73) or routine care of the cuff pressure (control group, n = 69). Patients remained in a semirecumbent position in bed. The primary end point variable was the incidence of ventilator-associated pneumonia. Main causes for intubation were decreased consciousness (43, 30%) and exacerbation of chronic respiratory diseases (38, 27%). Cuff pressure <20 cm H2O was more frequently observed in the control than the automatic group (45.3 vs. 0.7% determinations, p < .001). However, the rate of ventilator-associated pneumonia with clinical criteria (16, 22% vs. 20, 29%) and microbiological confirmation (11, 15% vs. 10, 15%), the distribution of early and late onset, the causative microorganisms, and intensive care unit (20, 27% vs. 16, 23%) and hospital mortality (30, 41% vs. 23, 33%) were similar for the automatic and control groups, respectively. Cuff pressure is better controlled with the automatic device. However, it did not result in additional benefits to the semirecumbent position in preventing ventilator-associated pneumonia.

  2. PLATO--AN AUTOMATED TEACHING DEVICE.

    ERIC Educational Resources Information Center

    BITZER, D.; AND OTHERS

    PLATO (PROGRAMED LOGIC FOR AUTOMATIC TEACHING OPERATION) IS A DEVICE FOR TEACHING A NUMBER OF STUDENTS INDIVIDUALLY BY MEANS OF A SINGLE, CENTRAL PURPOSE, DIGITAL COMPUTER. THE GENERAL ORGANIZATION OF EQUIPMENT CONSISTS OF A KEYSET FOR STUDENT RESPONSES, THE COMPUTER, STORAGE DEVICE (ELECTRIC BLACKBOARD), SLIDE SELECTOR (ELECTRICAL BOOK), AND TV…

  3. Precision centering vise

    NASA Technical Reports Server (NTRS)

    Thompson, J. A.

    1977-01-01

    Lightweight device automatically alines stainless-steel tubing and fittings, regardless of differing diameters, prior to joining via induction brazing. Device is useful in remote areas where existing supports or walls cannot be used to anchor tubing holder.

  4. Work zone speed reduction utilizing dynamic speed signs

    DOT National Transportation Integrated Search

    2011-08-30

    Vast quantities of transportation data are automatically recorded by intelligent transportations infrastructure, such as inductive loop detectors, video cameras, and side-fire radar devices. Such devices are typically deployed by traffic management c...

  5. 49 CFR 236.507 - Brake application; full service.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.507 Brake application; full service. The automatic train stop or train control apparatus shall, when operated, cause a full service...

  6. 49 CFR 236.507 - Brake application; full service.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.507 Brake application; full service. The automatic train stop or train control apparatus shall, when operated, cause a full service...

  7. Synthesis of actual knowledge on machine-tool monitoring methods and equipment

    NASA Astrophysics Data System (ADS)

    Tanguy, J. C.

    1988-06-01

    Problems connected with the automatic supervision of production were studied. Many different automatic control devices are now able to identify defects in the tools, but the solutions proposed to detect optimal limits in the utilization of a tool are not satisfactory.

  8. Engineering model of the electric drives of separation device for simulation of automatic control systems of reactive power compensation by means of serially connected capacitors

    NASA Astrophysics Data System (ADS)

    Juromskiy, V. M.

    2016-09-01

    It is developed a mathematical model for an electric drive of high-speed separation device in terms of the modeling dynamic systems Simulink, MATLAB. The model is focused on the study of the automatic control systems of the power factor (Cosφ) of an actuator by compensating the reactive component of the total power by switching a capacitor bank in series with the actuator. The model is based on the methodology of the structural modeling of dynamic processes.

  9. Automatic Rotational Sky Quality Meter (R-SQM) Design and Software for Astronomical Observatories

    NASA Astrophysics Data System (ADS)

    Dogan, E.; Ozbaldan, E. E.; Shameoni, Niaei M.; Yesilyaprak, C.

    2016-12-01

    We have presented the new design of Sky Quality Meter (SQM) device that is an automatic rotational model of sky quality meter (R-SQM) carried out by DAG (Eastern Anatolia Observatory) Technical Team. R-SQM is required for determining the long-term changes of sky quality of an astronomical observatory and consists of four SQM devices mounted on a rotating shaft with different angles for scanning all sky. This system is controlled by a Raspberry Pi control card and a step motor with its driver and a special software.

  10. A Venturi microregulator array module for distributed pressure control

    PubMed Central

    Chang, Dustin S.; Langelier, Sean M.; Zeitoun, Ramsey I.

    2010-01-01

    Pressure-driven flow control systems are a critical component in many microfluidic devices. Compartmentalization of this functionality into a stand-alone module possessing a simple interface would allow reduction of the number of pneumatic interconnects required for fluidic control. Ideally, such a module would also be sufficiently compact for implementation in portable platforms. In our current work, we show the feasibility of using a modular array of Venturi pressure microregulators for coordinated droplet manipulation. The arrayed microregulators share a single pressure input and are capable of outputting electronically controlled pressures that can be independently set between ±1.3 kPa. Because the Venturi microregulator operates by thermal perturbation of a choked gas flow, this output range corresponds to a temperature variation between 20 and 95°C. Using the array, we demonstrate loading, splitting, merging, and independent movement of multiple droplets in a valveless microchannel network. PMID:20938490

  11. 49 CFR 236.513 - Audible indicator.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.513 Audible indicator. (a) The automatic cab signal... control system shall have a distinctive sound and be clearly audible throughout the cab under all...

  12. 49 CFR 236.513 - Audible indicator.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.513 Audible indicator. (a) The automatic cab signal... control system shall have a distinctive sound and be clearly audible throughout the cab under all...

  13. 49 CFR 236.587 - Departure test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.587 Departure test. (a) The automatic train stop, train control, or cab signal apparatus on each locomotive, except a locomotive or a...

  14. Automatic food detection in egocentric images using artificial intelligence technology

    USDA-ARS?s Scientific Manuscript database

    Our objective was to develop an artificial intelligence (AI)-based algorithm which can automatically detect food items from images acquired by an egocentric wearable camera for dietary assessment. To study human diet and lifestyle, large sets of egocentric images were acquired using a wearable devic...

  15. Sound transmission in ducts containing nearly choked flows

    NASA Technical Reports Server (NTRS)

    Callegari, A. J.; Myers, M. K.

    1979-01-01

    The nonlinear theory previously developed by the authors (1977, 1978) is used to obtain numerical results for sound transmission through a nearly choked throat in a variable-area duct. Parametric studies are performed for different source locations, strengths and frequencies. It is shown that the nonlinear interactions in the throat region generate superharmonics of the fundamental (source) frequency throughout the duct. The amplitudes of these superharmonics increase as the source parameters (frequency and strength) are increased toward values leading to acoustic shocks. For a downstream source, superharmonics carry about 20% of the total acoustic power as shocking conditions are approached. For the source strength levels and frequencies considered, streaming effects are negligible.

  16. Development of a robust MRI fiducial system for automated fusion of MR-US abdominal images.

    PubMed

    Favazza, Christopher P; Gorny, Krzysztof R; Callstrom, Matthew R; Kurup, Anil N; Washburn, Michael; Trester, Pamela S; Fowler, Charles L; Hangiandreou, Nicholas J

    2018-05-21

    We present the development of a two-component magnetic resonance (MR) fiducial system, that is, a fiducial marker device combined with an auto-segmentation algorithm, designed to be paired with existing ultrasound probe tracking and image fusion technology to automatically fuse MR and ultrasound (US) images. The fiducial device consisted of four ~6.4 mL cylindrical wells filled with 1 g/L copper sulfate solution. The algorithm was designed to automatically segment the device in clinical abdominal MR images. The algorithm's detection rate and repeatability were investigated through a phantom study and in human volunteers. The detection rate was 100% in all phantom and human images. The center-of-mass of the fiducial device was robustly identified with maximum variations of 2.9 mm in position and 0.9° in angular orientation. In volunteer images, average differences between algorithm-measured inter-marker spacings and actual separation distances were 0.53 ± 0.36 mm. "Proof-of-concept" automatic MR-US fusions were conducted with sets of images from both a phantom and volunteer using a commercial prototype system, which was built based on the above findings. Image fusion accuracy was measured to be within 5 mm for breath-hold scanning. These results demonstrate the capability of this approach to automatically fuse US and MR images acquired across a wide range of clinical abdominal pulse sequences. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  17. Image acquisition device of inspection robot based on adaptive rotation regulation of polarizer

    NASA Astrophysics Data System (ADS)

    Dong, Maoqi; Wang, Xingguang; Liang, Tao; Yang, Guoqing; Zhang, Chuangyou; Gao, Faqin

    2017-12-01

    An image processing device of inspection robot with adaptive polarization adjustment is proposed, that the device includes the inspection robot body, the image collecting mechanism, the polarizer and the polarizer automatic actuating device. Where, the image acquisition mechanism is arranged at the front of the inspection robot body for collecting equipment image data in the substation. Polarizer is fixed on the automatic actuating device of polarizer, and installed in front of the image acquisition mechanism, and that the optical axis of the camera vertically goes through the polarizer and the polarizer rotates with the optical axis of the visible camera as the central axis. The simulation results show that the system solves the fuzzy problems of the equipment that are caused by glare, reflection of light and shadow, and the robot can observe details of the running status of electrical equipment. And the full coverage of the substation equipment inspection robot observation target is achieved, which ensures the safe operation of the substation equipment.

  18. 14 CFR 60.27 - Automatic loss of qualification and procedures for restoration of qualification.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Automatic loss of qualification and procedures for restoration of qualification. 60.27 Section 60.27 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIRMEN FLIGHT SIMULATION TRAINING DEVICE INITIAL AND...

  19. 14 CFR 60.27 - Automatic loss of qualification and procedures for restoration of qualification.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Automatic loss of qualification and procedures for restoration of qualification. 60.27 Section 60.27 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIRMEN FLIGHT SIMULATION TRAINING DEVICE INITIAL AND...

  20. 14 CFR 60.27 - Automatic loss of qualification and procedures for restoration of qualification.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Automatic loss of qualification and procedures for restoration of qualification. 60.27 Section 60.27 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIRMEN FLIGHT SIMULATION TRAINING DEVICE INITIAL AND...

  1. 14 CFR 60.27 - Automatic loss of qualification and procedures for restoration of qualification.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Automatic loss of qualification and procedures for restoration of qualification. 60.27 Section 60.27 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIRMEN FLIGHT SIMULATION TRAINING DEVICE INITIAL AND...

  2. 14 CFR 60.27 - Automatic loss of qualification and procedures for restoration of qualification.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Automatic loss of qualification and procedures for restoration of qualification. 60.27 Section 60.27 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIRMEN FLIGHT SIMULATION TRAINING DEVICE INITIAL AND...

  3. 49 CFR 236.563 - Delay time.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Locomotives § 236.563 Delay time. Delay time of automatic train stop or train control system shall not exceed 8 seconds and the spacing of signals to meet the...

  4. 49 CFR 236.588 - Periodic test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.588 Periodic test. Except as provided in § 236.586, periodic test of the automatic train stop, train control, or cab signal apparatus...

  5. 49 CFR 236.528 - Restrictive condition resulting from open hand-operated switch; requirement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and... with circuit controller is used, the resultant restrictive condition of an automatic train stop or...

  6. 49 CFR 236.509 - Two or more locomotives coupled.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.509 Two or more locomotives coupled. The automatic train stop, train control or cab signal apparatus shall be arranged so that when two or...

  7. 49 CFR 236.514 - Interconnection of cab signal system with roadway signal system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.514 Interconnection of cab signal system with roadway signal system. The automatic cab signal system shall be...

  8. 49 CFR 236.528 - Restrictive condition resulting from open hand-operated switch; requirement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and... with circuit controller is used, the resultant restrictive condition of an automatic train stop or...

  9. 49 CFR 236.554 - Rate of pressure reduction; equalizing reservoir or brake pipe.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions... pressure or brake-pipe pressure reduction during an automatic brake application shall be at a rate not less...

  10. 49 CFR 236.511 - Cab signals controlled in accordance with block conditions stopping distance in advance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards... automatic cab signal system shall be arranged so that cab signals will be continuously controlled in...

  11. 49 CFR 236.554 - Rate of pressure reduction; equalizing reservoir or brake pipe.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions... pressure or brake-pipe pressure reduction during an automatic brake application shall be at a rate not less...

  12. 49 CFR 236.509 - Two or more locomotives coupled.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.509 Two or more locomotives coupled. The automatic train stop, train control or cab signal apparatus shall be arranged so that when two or...

  13. A Flexible and Configurable Architecture for Automatic Control Remote Laboratories

    ERIC Educational Resources Information Center

    Kalúz, Martin; García-Zubía, Javier; Fikar, Miroslav; Cirka, Luboš

    2015-01-01

    In this paper, we propose a novel approach in hardware and software architecture design for implementation of remote laboratories for automatic control. In our contribution, we show the solution with flexible connectivity at back-end, providing features of multipurpose usage with different types of experimental devices, and fully configurable…

  14. 47 CFR 80.275 - Technical Requirements for Class A Automatic Identification System (AIS) equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Compulsory Ships § 80.275 Technical Requirements for Class A Automatic Identification System (AIS) equipment. (a) Prior to submitting a certification application for a Class A AIS device, the following... Identification System (AIS) equipment. 80.275 Section 80.275 Telecommunication FEDERAL COMMUNICATIONS COMMISSION...

  15. 47 CFR 80.275 - Technical Requirements for Class A Automatic Identification System (AIS) equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Compulsory Ships § 80.275 Technical Requirements for Class A Automatic Identification System (AIS) equipment. (a) Prior to submitting a certification application for a Class A AIS device, the following... Identification System (AIS) equipment. 80.275 Section 80.275 Telecommunication FEDERAL COMMUNICATIONS COMMISSION...

  16. 47 CFR 80.275 - Technical Requirements for Class A Automatic Identification System (AIS) equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Compulsory Ships § 80.275 Technical Requirements for Class A Automatic Identification System (AIS) equipment. (a) Prior to submitting a certification application for a Class A AIS device, the following... Identification System (AIS) equipment. 80.275 Section 80.275 Telecommunication FEDERAL COMMUNICATIONS COMMISSION...

  17. 47 CFR 80.275 - Technical Requirements for Class A Automatic Identification System (AIS) equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Compulsory Ships § 80.275 Technical Requirements for Class A Automatic Identification System (AIS) equipment. (a) Prior to submitting a certification application for a Class A AIS device, the following... Identification System (AIS) equipment. 80.275 Section 80.275 Telecommunication FEDERAL COMMUNICATIONS COMMISSION...

  18. Photonic correlator pattern recognition: Application to autonomous docking

    NASA Technical Reports Server (NTRS)

    Sjolander, Gary W.

    1991-01-01

    Optical correlators for real-time automatic pattern recognition applications have recently become feasible due to advances in high speed devices and filter formulation concepts. The devices are discussed in the context of their use in autonomous docking.

  19. Clinical evaluation of pacemaker automatic capture management and atrioventricular interval extension algorithm.

    PubMed

    Chen, Ke-ping; Xu, Geng; Wu, Shulin; Tang, Baopeng; Wang, Li; Zhang, Shu

    2013-03-01

    The present study was to assess the accuracy of automatic atrial and ventricular capture management (ACM and VCM) in determining pacing threshold and the performance of a second-generation automatic atrioventricular (AV) interval extension algorithm for reducing unnecessary ventricular pacing. A total of 398 patients at 32 centres who received an EnPulse dual-chamber pacing/dual-chamber adaptive rate pacing pacemaker (Medtronic, Minneapolis, MN, USA) were enrolled. The last amplitude thresholds as measured by ACM and VCM prior to the 6-month follow-up were compared with manually measured thresholds. Device diagnostics were used to evaluate ACM and VCM and the percentage of ventricular pacing with and without the AV extension algorithm. Modelling was performed to assess longevity gains relating to the use of automaticity features. Atrial and ventricular capture management performed accurately and reliably provided complete capture management in 97% of studied patients. The AV interval extension algorithm reduced the median per cent of right ventricular pacing in patients with sinus node dysfunction from 99.7 to 1.5% at 6-month follow-up and in patients with intermittent AV block (excluding persistent 3° AV block) from 99.9 to 50.2%. On the basis of validated modelling, estimated device longevity could potentially be extended by 1.9 years through the use of the capture management and AV interval extension features. Both ACM and VCM features reliably measured thresholds in nearly all patients; the AV extension algorithm significantly reduced ventricular pacing; and the use of pacemaker automaticity features potentially extends device longevity.

  20. CONTROL LIMITER DEVICE

    DOEpatents

    DeShong, J.A.

    1960-03-01

    A control-limiting device for monltoring a control system is described. The system comprises a conditionsensing device, a condition-varying device exerting a control over the condition, and a control means to actuate the condition-varying device. A control-limiting device integrates the total movement or other change of the condition-varying device over any interval of time during a continuum of overlapping periods of time, and if the tothl movement or change of the condition-varying device exceeds a preset value, the control- limiting device will switch the control of the operated apparatus from automatic to manual control.

  1. Validation of the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol.

    PubMed

    Chen, Wan; Zeng, Zhao-Lin; Bing, Sen; Li, Lin-Yi; Wang, Rui; Wan, Yi

    2016-08-01

    The aim of the present study was to validate the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. The ESH-IP revision 2010 for the validation of blood pressure-measuring devices in adults was followed precisely. Systolic and diastolic blood pressure (SBP and DBP, respectively) were measured sequentially in 33 adult patients and compared with a standard mercury sphygmomanometer (two observers). A total of 99 comparison pairs were obtained. The device produced 78, 95 and 99 measurements within 5, 10, and 15 mmHg for SBP and 83, 96, and 99 for DBP, respectively. The average device-observer difference was -1.81±4.22 mmHg for SBP and -0.15±3.93 mmHg for DBP. All of the data were within the standards requirements to pass the testing. The Grandway MD2301 digital automatic blood pressure monitor meets the standards of the ESH-IP revision 2010 and can be recommended for self/home measurement in the general population.

  2. Responding to a Choking Emergency

    MedlinePlus

    ... Healthy Living Healthy Living Healthy Living Nutrition Fitness Sports Oral Health Emotional Wellness Growing Healthy Sleep Safety & Prevention Safety & Prevention Safety and Prevention Immunizations ...

  3. Automatic atrial capture device control in real-life practice: A multicenter experience.

    PubMed

    Giammaria, Massimo; Quirino, Gianluca; Alberio, Mariangela; Parravicini, Umberto; Cipolla, Eliana; Rossetti, Guido; Ruocco, Antonio; Senatore, Gaetano; Rametta, Francesco; Pistelli, Paolo

    2017-04-01

    Device-based fully automatic pacing capture detection is useful in clinical practice and important in the era of remote care management. The main objective of this study was to verify the effectiveness of the new ACAP Confirm® algorithm in managing atrial capture in the medium term in comparison with early post-implantation testing. Data were collected from 318 patients (66% male; mean age, 73±10 years); 237 of these patients underwent device implantation and 81 box changes in 31 Italian hospitals. Atrial threshold measurements were taken manually and automatically at different pulse widths before discharge and during follow-up (7±2 months) examination. The algorithm worked as expected in 73% of cases, considering all performed tests. The success rate was 65% and 88% pre-discharge and during follow-up examination ( p <0.001), respectively, in patients who had undergone implantation. We did not detect any difference in the performance of the algorithm as a result of the type of atrial lead used. The success rate was 70% during pre-discharge testing in patients undergoing device replacement. Considering all examination types, manual and automatic measurements yielded threshold values of 1.07±0.47 V and 1.03±0.47 V at 0.2-ms pulse duration ( p =0.37); 0.66±0.37 V and 0.67±0.36 V at 0.4 ms ( p =0.42); and 0.5±0.28 V and 0.5±0.29 V at 1 ms ( p =0.32). The results show that the algorithm works before discharge, and its reliability increases over the medium term. The algorithm also proved accurate in detecting the atrial threshold automatically. The possibility of activating it does not seem to be influenced by the lead type used, but by the time from implantation.

  4. Automatic segmentation and centroid detection of skin sensors for lung interventions

    NASA Astrophysics Data System (ADS)

    Lu, Kongkuo; Xu, Sheng; Xue, Zhong; Wong, Stephen T.

    2012-02-01

    Electromagnetic (EM) tracking has been recognized as a valuable tool for locating the interventional devices in procedures such as lung and liver biopsy or ablation. The advantage of this technology is its real-time connection to the 3D volumetric roadmap, i.e. CT, of a patient's anatomy while the intervention is performed. EM-based guidance requires tracking of the tip of the interventional device, transforming the location of the device onto pre-operative CT images, and superimposing the device in the 3D images to assist physicians to complete the procedure more effectively. A key requirement of this data integration is to find automatically the mapping between EM and CT coordinate systems. Thus, skin fiducial sensors are attached to patients before acquiring the pre-operative CTs. Then, those sensors can be recognized in both CT and EM coordinate systems and used calculate the transformation matrix. In this paper, to enable the EM-based navigation workflow and reduce procedural preparation time, an automatic fiducial detection method is proposed to obtain the centroids of the sensors from the pre-operative CT. The approach has been applied to 13 rabbit datasets derived from an animal study and eight human images from an observation study. The numerical results show that it is a reliable and efficient method for use in EM-guided application.

  5. Automated imaging of cellular spheroids with selective plane illumination microscopy on a chip (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Paiè, Petra; Bassi, Andrea; Bragheri, Francesca; Osellame, Roberto

    2017-02-01

    Selective plane illumination microscopy (SPIM) is an optical sectioning technique that allows imaging of biological samples at high spatio-temporal resolution. Standard SPIM devices require dedicated set-ups, complex sample preparation and accurate system alignment, thus limiting the automation of the technique, its accessibility and throughput. We present a millimeter-scaled optofluidic device that incorporates selective plane illumination and fully automatic sample delivery and scanning. To this end an integrated cylindrical lens and a three-dimensional fluidic network were fabricated by femtosecond laser micromachining into a single glass chip. This device can upgrade any standard fluorescence microscope to a SPIM system. We used SPIM on a CHIP to automatically scan biological samples under a conventional microscope, without the need of any motorized stage: tissue spheroids expressing fluorescent proteins were flowed in the microchannel at constant speed and their sections were acquired while passing through the light sheet. We demonstrate high-throughput imaging of the entire sample volume (with a rate of 30 samples/min), segmentation and quantification in thick (100-300 μm diameter) cellular spheroids. This optofluidic device gives access to SPIM analyses to non-expert end-users, opening the way to automatic and fast screening of a high number of samples at subcellular resolution.

  6. PLC based automatic control of pasteurize mix in ice cream production

    NASA Astrophysics Data System (ADS)

    Yao, Xudong; Liang, Kai

    2013-03-01

    This paper describes the automatic control device of pasteurized mix in the ice cream production process.We design a scheme of control system using FBD program language and develop the programmer in the STEP 7-Micro/WIN software, check for any bugs before downloading into PLC .These developed devices will able to provide flexibility and accuracy to control the step of pasteurized mix. The operator just Input the duration and temperature of pasteurized mix through control panel. All the steps will finish automatically without any intervention in a preprogrammed sequence stored in programmable logic controller (PLC). With the help of this equipment we not only can control the quality of ice cream for various conditions, but also can simplify the production process. This control system is inexpensive and can be widely used in ice cream production industry.

  7. Dysphagia is a common and serious problem for adults with mental illness: a systematic review.

    PubMed

    Aldridge, Kristy J; Taylor, Nicholas F

    2012-03-01

    Adults with mental illness may experience a higher incidence of dysphagia and choking due to factors such as medication side effects and behavioural abnormalities. The aim of this study was to determine the frequency of dysphagia and the most effective interventions for this population. Studies published up to August 2010 were sought via a comprehensive electronic database search (CINAHL, PsycINFO, MEDLINE, PubMed, Cochrane, and Embase). Studies reporting dysphagia frequency or dysphagia intervention outcomes in adults with mental illness were included. Two reviewers independently assessed study eligibility and quality, and the results were synthesised descriptively. Ten studies were identified, each describing dysphagia frequency or death due to choking asphyxiation. No studies evaluating intervention effectiveness were identified. Study quality was limited by subjective assessment of outcomes. Six studies presented dysphagia frequencies ranging from 9 to 42% in varying subgroups. Four studies presented the frequency of choking asphyxiation death, including a large survey that concluded that adults with organic mental illness were 43 times more likely to die of this cause than the general population. Dysphagia is a common and significant cause of morbidity and mortality in adults with mental illness and our review found that there is a lack of studies evaluating the effectiveness of intervention techniques.

  8. Detailed analysis of the flow in the inducer of a transonic centrifugal compressor

    NASA Astrophysics Data System (ADS)

    Buffaz, Nicolas; Trébinjac, Isabelle

    2012-02-01

    Numerical and experimental investigations were conducted in a transonic centrifugal compressor stage composed of a backswept splittered unshrouded impeller and a vaned diffuser. A detailed analysis of the flow in the inducer (i.e. the entry zone of the impeller between the main blade leading edge and the splitter blade leading edge) is proposed from choke to surge. Steady and unsteady simulations were performed using the code elsA, which uses a multi-domain approach on structured meshes and solves the compressible RANS equations, associated with a two-equation turbulence model k-l in the rotating frame of reference. The 1MW LMFA-ECL test rig was used for carrying out the tests in the compressor stage. Unsteady pressure measurements up to 150 kHz and Laser Doppler Anemometry measurements were performed in the inducer. A good agreement is obtained between the experimental and numerical data even if an over dissipation is noticed in the numerical results. The change in flow pattern from choke to surge is mainly due to a change in the tip leakage flow trajectory which straightens, leading to a flow blockage of an individual passage near shroud. A spectral analysis shows that only the blade passing frequency and its harmonics compose the various spectra obtained from choke to surge.

  9. Investigation of combustion control in a dump combustor using the feedback free fluidic oscillator

    NASA Astrophysics Data System (ADS)

    Meier, Eric J.

    The feedback free fluidic oscillator uses the unsteady nature of two colliding jets to create a single oscillating outlet jet with a wide sweep angle. These devices have the potential to provide additional combustion control, boundary layer control, thrust vectoring, and industrial flow deflection. Two-dimensional computational fluid dynamics, CFD, was used to analyze the jet oscillation frequency over a range of operating conditions and to determine the effect that geometric changes in the oscillator design have on the frequency. Results presented illustrate the changes in jet oscillation frequency with gas type, gas temperature, operating pressure, pressure ratio across the oscillator, aspect ratio of the oscillator, and the frequency trends with various changes to the oscillator geometry. A fluidic oscillator was designed and integrated into single element rocket combustor with the goal of suppressing longitudinal combustion instabilities. An array of nine fluidic oscillators was tested to mimic modulated secondary oxidizer injection into the dump plane using 15% of the oxidizer flow. The combustor has a coaxial injector that uses gaseous methane and decomposed hydrogen peroxide at an O/F of 11.66. A sonic choke plate on an actuator arm allows for continuous adjustment of the oxidizer post acoustics for studying a variety of instability magnitudes. The fluidic oscillator unsteady outlet jet performance is compared with equivalent steady jet injection and a baseline design with no secondary oxidizer injection. At the most unstable operating conditions, the unsteady outlet jet saw a 60% reduction in the instability pressure oscillation magnitude when compared to the steady jet and baseline data. The results indicate open loop propellant modulation for combustion control can be achieved through fluidic devices that require no moving parts or electrical power to operate. Three-dimensional computational fluid dynamics, 3-D CFD, was conducted to determine the mechanism by which the fluidic oscillators were able to suppress the combustion instability. Results for steady jet secondary injection, showed a strong coupling between the jet injection and the combustion instability pressure pulse. The computational results were able to closely match the experimental results and previous CFD data. The model with the oscillating fluidic oscillator injection was unable to match the stable combustion seen in the experimental data. Further investigation is needed to determine the role higher order chemistry kinetics play in the process and the role of manifolds on the un-choked fuel and fluidic oscillator inlets. This research demonstrates the ability to modulate propellant injection and suppress combustion instabilities using fluidic devices that require no electrical power or moving parts. The advent of advanced manufacturing technologies such as direct metal laser sintering will allow for integration of fluidic devices into combustors to provide open loop active control with a high degree of reliability. Additionally, 2-D CFD analysis is demonstrated to be a valid tool for predicting the feedback free fluidic oscillator oscillation mechanism.

  10. Automatic safety rod for reactors. [LMFBR

    DOEpatents

    Germer, J.H.

    1982-03-23

    An automatic safety rod for a nuclear reactor containing neutron absorbing material and designed to be inserted into a reactor core after a loss-of-flow. Actuation is based upon either a sudden decrease in core pressure drop or the pressure drop decreases below a predetermined minimum value. The automatic control rod includes a pressure regulating device whereby a controlled decrease in operating pressure due to reduced coolant flow does not cause the rod to drop into the core.

  11. Automatic safety rod for reactors

    DOEpatents

    Germer, John H.

    1988-01-01

    An automatic safety rod for a nuclear reactor containing neutron absorbing material and designed to be inserted into a reactor core after a loss-of-core flow. Actuation is based upon either a sudden decrease in core pressure drop or the pressure drop decreases below a predetermined minimum value. The automatic control rod includes a pressure regulating device whereby a controlled decrease in operating pressure due to reduced coolant flow does not cause the rod to drop into the core.

  12. 49 CFR 236.567 - Restrictions imposed when device fails and/or is cut out en route.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Restrictions imposed when device fails and/or is...; Locomotives § 236.567 Restrictions imposed when device fails and/or is cut out en route. Where an automatic train stop, train control, or cab signal device fails and/or is cut out enroute, train may proceed at...

  13. 47 CFR 80.231 - Technical Requirements for Class B Automatic Identification System (AIS) equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... data in the device shall also be included in the user's manual for the device. The entry of static data... Communications Commission to input an MMSI that has not been properly assigned to the end user, or to otherwise... shall the entry of static data into a Class B AIS device be performed by the user of the device or the...

  14. Congenital hairy polyp of the oropharynx presenting as an esophageal mass in a neonate, a case report and literature review.

    PubMed

    Richter, Amy; Mysore, Krupa; Schady, Deb; Chandy, Binoy

    2016-01-01

    To review the literature of congenital hairy polyps and describe the clinical presentation, operative management, and histologic findings of a congenital hairy polyp arising from the palatopharyngeus muscle in a neonate with recurrent choking episodes. Chart review of a 2-month-old male referred to a tertiary care pediatric hospital. We present a case of a 2-month-old male who presented to the emergency room with recurrent episodes of choking and vomiting. The patient was previously healthy with no prior medical or neonatal history. The parents noted a small fleshy mass in the patient's oropharynx that he would chew on and swallow after several minutes. However, on physical exam, there was no evidence of oropharyngeal mass. The patient did not have respiratory distress. Imaging revealed a 22×7×11mm oblong, fatty mass in the lower cervical and upper thoracic esophagus with a thin stalk extending proximally to the upper collapsed esophagus. Intraoperative recorded laryngoscopy revealed a pedunculated soft palate mass attached to the right superior palatopharyngeus muscle. Histopathology revealed ectodermal and mesodermal elements in a polypoid structure lined by keratinizing squamous epithelium with adnexal structures and central mature adipose tissue, consistent with congenital hairy polyp resembling an accessory tragus of the ear and branchial anomaly. At 6-week follow up, the patient was doing well and gaining weight appropriately with no further choking episodes. There was no evidence of velopharyngeal dysfunction on follow up exam. The surgical site was completely healed and there was no evidence of recurrence. Congenital hairy polyps of the naso- and oropharynx are rare but may present as airway or esophageal masses, causing respiratory distress or choking episodes in a pediatric patient. The pathologic findings of keratinizing squamous epithelium, adnexal structures, adipose and cartilage tissues resemble congenital accessory tragus and may be considered a branchial arch anomaly. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Vital Recorder-a free research tool for automatic recording of high-resolution time-synchronised physiological data from multiple anaesthesia devices.

    PubMed

    Lee, Hyung-Chul; Jung, Chul-Woo

    2018-01-24

    The current anaesthesia information management system (AIMS) has limited capability for the acquisition of high-quality vital signs data. We have developed a Vital Recorder program to overcome the disadvantages of AIMS and to support research. Physiological data of surgical patients were collected from 10 operating rooms using the Vital Recorder. The basic equipment used were a patient monitor, the anaesthesia machine, and the bispectral index (BIS) monitor. Infusion pumps, cardiac output monitors, regional oximeter, and rapid infusion device were added as required. The automatic recording option was used exclusively and the status of recording was frequently checked through web monitoring. Automatic recording was successful in 98.5% (4,272/4,335) cases during eight months of operation. The total recorded time was 13,489 h (3.2 ± 1.9 h/case). The Vital Recorder's automatic recording and remote monitoring capabilities enabled us to record physiological big data with minimal effort. The Vital Recorder also provided time-synchronised data captured from a variety of devices to facilitate an integrated analysis of vital signs data. The free distribution of the Vital Recorder is expected to improve data access for researchers attempting physiological data studies and to eliminate inequalities in research opportunities due to differences in data collection capabilities.

  16. Evaluation of an improved flotation device for infants and small children.

    DOT National Transportation Integrated Search

    1971-07-01

    A simple, lightweight, life-support infant flotation device incorporating reliable self-righting, thermal protection and automatic self-ventilation is described This design concept utilizes prior data relative to the centers of gravity of infants and...

  17. Automatic cross-sectioning and monitoring system locates defects in electronic devices

    NASA Technical Reports Server (NTRS)

    Jacobs, G.; Slaughter, B.

    1971-01-01

    System consists of motorized grinding and lapping apparatus, sample holder, and electronic control circuit. Low power microscope examines device to pinpoint location of circuit defect, and monitor displays output signal when defect is located exactly.

  18. Blockage of upper airway

    MedlinePlus

    ... or fidgeting Bluish color to the skin ( cyanosis ) Changes in consciousness Choking Confusion Difficulty breathing , gasping for air, leading to panic Unconsciousness Wheezing , crowing, whistling, or other ...

  19. The Nagoya cosmic-ray muon spectrometer 3, part 3: Automatic film scanning equipment

    NASA Technical Reports Server (NTRS)

    Shibata, S.; Kamiya, Y.; Iijima, K.; Iida, S.

    1985-01-01

    In the regular operation of the Nagoya cosmic-ray muon spectrometer, about 2000 events per day will be recorded on the photographic film. To derive the track locations from such a huge number of photographs with high accuracy in a short time, an automatic film scanning device has been developed.

  20. 49 CFR 236.508 - Interference with application of brakes by means of brake valve.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.508 Interference with application of brakes by means of brake valve. The automatic train stop, train control, or...

  1. 49 CFR 236.512 - Cab signal indication when locomotive enters block where restrictive conditions obtain.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.512 Cab signal indication when locomotive enters block where restrictive conditions obtain. The automatic cab signal system shall be arranged so that when a locomotive enters or is...

  2. 49 CFR 236.508 - Interference with application of brakes by means of brake valve.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.508 Interference with application of brakes by means of brake valve. The automatic train stop, train control, or...

  3. What Are the Safety Considerations for Insulin Control for Athletes?

    ERIC Educational Resources Information Center

    McDaniel, Larry W.; Olson, Sara; Gaudet, Laura; Jackson, Allen

    2010-01-01

    Athletes diagnosed with diabetes may have difficulty with their blood sugar levels fluctuating during intense exercise. Considerations for athletes with insulin concerns may range anywhere from exercise rehabilitation to the use of an automatic insulin pump. The automatic insulin pump is a small battery-operated device about the size of a pager.…

  4. 49 CFR 236.311 - Signal control circuits, selection through track relays or devices functioning as track relays...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... automatic interlocking. (a) The control circuits for aspects with indications more favorable than “proceed... 49 Transportation 4 2010-10-01 2010-10-01 false Signal control circuits, selection through track... automatic interlocking. 236.311 Section 236.311 Transportation Other Regulations Relating to Transportation...

  5. Drinking behavior in nursery pigs: Determining the accuracy between an automatic water meter versus human observers

    USDA-ARS?s Scientific Manuscript database

    Assimilating accurate behavioral events over a long period can be labor intensive and relatively expensive. If an automatic device could accurately record the duration and frequency for a given behavioral event, it would be a valuable alternative to the traditional use of human observers for behavio...

  6. 49 CFR 571.123 - Standard No. 123; Motorcycle controls and displays.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... handgrip. If a motorcycle with an automatic clutch other than a scooter is equipped with a supplemental rear brake control, the control shall be located on the left handlebar. If a scooter with an automatic... equipped with self-proportioning or antilock braking devices utilizing a single control for front and rear...

  7. A Study on the Development of a Robot-Assisted Automatic Laser Hair Removal System

    PubMed Central

    Lim, Hyoung-woo; Park, Sungwoo; Noh, Seungwoo; Lee, Dong-Hun; Yoon, Chiyul; Koh, Wooseok; Kim, Youdan; Chung, Jin Ho; Kim, Hee Chan

    2014-01-01

    Abstract Background and Objective: The robot-assisted automatic laser hair removal (LHR) system is developed to automatically detect any arbitrary shape of the desired LHR treatment area and to provide uniform laser irradiation to the designated skin area. Methods: For uniform delivery of laser energy, a unit of a commercial LHR device, a laser distance sensor, and a high-resolution webcam are attached at the six axis industrial robot's end-effector, which can be easily controlled using a graphical user interface (GUI). During the treatment, the system provides real-time treatment progress as well as the total number of “pick and place” automatically. Results: During the test, it was demonstrated that the arbitrary shapes were detected, and that the laser was delivered uniformly. The localization error test and the area-per-spot test produced satisfactory outcome averages of 1.04 mm error and 38.22 mm2/spot, respectively. Conclusions: Results showed that the system successfully demonstrated accuracy and effectiveness. The proposed system is expected to become a promising device in LHR treatment. PMID:25343281

  8. A study on the development of a robot-assisted automatic laser hair removal system.

    PubMed

    Lim, Hyoung-Woo; Park, Sungwoo; Noh, Seungwoo; Lee, Dong-Hun; Yoon, Chiyul; Koh, Wooseok; Kim, Youdan; Chung, Jin Ho; Kim, Hee Chan; Kim, Sungwan

    2014-11-01

    Abstract Background and Objective: The robot-assisted automatic laser hair removal (LHR) system is developed to automatically detect any arbitrary shape of the desired LHR treatment area and to provide uniform laser irradiation to the designated skin area. For uniform delivery of laser energy, a unit of a commercial LHR device, a laser distance sensor, and a high-resolution webcam are attached at the six axis industrial robot's end-effector, which can be easily controlled using a graphical user interface (GUI). During the treatment, the system provides real-time treatment progress as well as the total number of "pick and place" automatically. During the test, it was demonstrated that the arbitrary shapes were detected, and that the laser was delivered uniformly. The localization error test and the area-per-spot test produced satisfactory outcome averages of 1.04 mm error and 38.22 mm(2)/spot, respectively. RESULTS showed that the system successfully demonstrated accuracy and effectiveness. The proposed system is expected to become a promising device in LHR treatment.

  9. Miniature sonar fish tag

    NASA Technical Reports Server (NTRS)

    Lovelady, R. W.; Ferguson, R. L.

    1975-01-01

    Self-powered sonar device may be implanted in body of fish. It transmits signal that can be detected with portable tracking gear or by automatic detection-and-tracking system. Operating life of over 4000 hours may be expected. Device itself may be used almost indefinitely.

  10. 33 CFR 164.40 - Devices to indicate speed and distance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Devices to indicate speed and... speed and distance. (a) Each vessel required to be fitted with an Automatic Radar Plotting Aid (ARPA) under § 164.38 of this part must be fitted with a device to indicate speed and distance of the vessel...

  11. 33 CFR 164.40 - Devices to indicate speed and distance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Devices to indicate speed and... speed and distance. (a) Each vessel required to be fitted with an Automatic Radar Plotting Aid (ARPA) under § 164.38 of this part must be fitted with a device to indicate speed and distance of the vessel...

  12. Automatic identification of artifacts in electrodermal activity data.

    PubMed

    Taylor, Sara; Jaques, Natasha; Chen, Weixuan; Fedor, Szymon; Sano, Akane; Picard, Rosalind

    2015-01-01

    Recently, wearable devices have allowed for long term, ambulatory measurement of electrodermal activity (EDA). Despite the fact that ambulatory recording can be noisy, and recording artifacts can easily be mistaken for a physiological response during analysis, to date there is no automatic method for detecting artifacts. This paper describes the development of a machine learning algorithm for automatically detecting EDA artifacts, and provides an empirical evaluation of classification performance. We have encoded our results into a freely available web-based tool for artifact and peak detection.

  13. An automatic pellet dispenser for precise control of feeding topography in granivorous birds

    PubMed Central

    Berkhoudt, H.; Van Der Reijden, D.; Heijmans, M.

    1987-01-01

    Design and construction of an automatic pellet dispenser for granivorous birds are described. The dispenser permits rapid pneumatic delivery of pellets (five pellets per second maximum) to one controlled position and does not interfere with simultaneous electrophysiological recording. In addition, the device continuously indicates presence or absence of a pellet in the delivery position. This automatic dispenser proved very effective in our studies of stereotyped topographies of feeding in granivorous birds, such as pigeons and chickens. PMID:16812503

  14. A tabulation of pipe length to diameter ratios as a function of Mach number and pressure ratios for compressible flow

    NASA Technical Reports Server (NTRS)

    Dixon, G. V.; Barringer, S. R.; Gray, C. E.; Leatherman, A. D.

    1975-01-01

    Computer programs and resulting tabulations are presented of pipeline length-to-diameter ratios as a function of Mach number and pressure ratios for compressible flow. The tabulations are applicable to air, nitrogen, oxygen, and hydrogen for compressible isothermal flow with friction and compressible adiabatic flow with friction. Also included are equations for the determination of weight flow. The tabulations presented cover a wider range of Mach numbers for choked, adiabatic flow than available from commonly used engineering literature. Additional information presented, but which is not available from this literature, is unchoked, adiabatic flow over a wide range of Mach numbers, and choked and unchoked, isothermal flow for a wide range of Mach numbers.

  15. Suicidal choking caused by a bizarre combination of inhalation to the bronchi and external neck compression.

    PubMed

    Pampin, J B; Varela, L G

    2001-06-01

    We report a remarkable case of suicidal choking in an elderly man with depressive episodes and one previous attempt of suicide. Initially, the presence of a sweater around his neck and blunt injuries on his head, left elbow and sacrum region seemed to indicate a suspicious violent death. During the necropsy study, a fragment of newspaper was discovered inside his lower respiratory tract. Autopsy findings showed minimal punctata haemorrhages on the larynx and trachea. The subsequent toxicological investigation was negative. This case is extremely rare, because the deceased was not a schizophrenic patient and the peculiar foreign object was found in the lower level. To the best of our knowledge, in medicolegal literature, few similar cases have been reported.

  16. Electrical treatment of atrial arrhythmias in heart failure patients implanted with a dual defibrillator CRT device. Results from the TRADE-HF study.

    PubMed

    Botto, Giovanni Luca; Padeletti, Luigi; Covino, Gregorio; Pieragnoli, Paolo; Liccardo, Mattia; Mariconti, Barbara; Favale, Stefano; Molon, Giulio; De Filippo, Paolo; Bolognese, Leonardo; Landolina, Maurizio; Raciti, Giovanni; Boriani, Giuseppe

    2017-06-01

    Ventricular and atrial arrhythmias commonly occur in heart failure patients and are a significant source of symptoms, morbidity and mortality. Some specific generators referred to as dual defibrillators, Dual CRT-Ds, have the ability to treat atrial and ventricular arrhythmias. TRADE-HF is a prospective two-arm randomized study aimed at assessing the benefits of complete automatic management of atrial arrhythmias in patients implanted with a dual CRT-D. Primary objective of the TRADE-HF study was to document reduction of unplanned hospital admission for cardiac reasons or death for cardiovascular causes or progression to permanent AF, by comparing fully-automatic device driven therapy for atrial tachycardia or fibrillation (AT/AF) to an in-hospital approach for treatment of symptomatic AT/AF. Randomized Patients were followed every 6months for 3years to assess the primary objective. Four-hundred-twenty patients have been enrolled in the study. At the end of the study 30 subjects died for cardiovascular causes, 60 had at least one hospitalization for cardiovascular causes and 14 developed permanent AF. Eighty-seven patients experienced a composite event. Hazard Ratio for device-managed automatic therapy arm compared to traditional was 0.987 (95% CI: 0.684-1.503; p=0.951). The primary endpoint analysis resulted in no difference between the device managed and in-hospital treatment arm. The TRADE-HF study failed to demonstrate a reduction in the composite of unplanned hospitalizations for cardiovascular causes or death for cardiovascular causes or progression to permanent AF using automatic atrial therapy compared to a traditional approach including hospitalization for symptomatic episodes and/or in-hospital treatment of AT/AF. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Diffraction phase microscopy realized with an automatic digital pinhole

    NASA Astrophysics Data System (ADS)

    Zheng, Cheng; Zhou, Renjie; Kuang, Cuifang; Zhao, Guangyuan; Zhang, Zhimin; Liu, Xu

    2017-12-01

    We report a novel approach to diffraction phase microscopy (DPM) with automatic pinhole alignment. The pinhole, which serves as a spatial low-pass filter to generate a uniform reference beam, is made out of a liquid crystal display (LCD) device that allows for electrical control. We have made DPM more accessible to users, while maintaining high phase measurement sensitivity and accuracy, through exploring low cost optical components and replacing the tedious pinhole alignment process with an automatic pinhole optical alignment procedure. Due to its flexibility in modifying the size and shape, this LCD device serves as a universal filter, requiring no future replacement. Moreover, a graphic user interface for real-time phase imaging has been also developed by using a USB CMOS camera. Experimental results of height maps of beads sample and live red blood cells (RBCs) dynamics are also presented, making this system ready for broad adaption to biological imaging and material metrology.

  18. Intelligent vision guide for automatic ventilation grommet insertion into the tympanic membrane.

    PubMed

    Gao, Wenchao; Tan, Kok Kiong; Liang, Wenyu; Gan, Chee Wee; Lim, Hsueh Yee

    2016-03-01

    Otitis media with effusion is a worldwide ear disease. The current treatment is to surgically insert a ventilation grommet into the tympanic membrane. A robotic device allowing automatic grommet insertion has been designed in a previous study; however, the part of the membrane where the malleus bone is attached to the inner surface is to be avoided during the insertion process. This paper proposes a synergy of optical flow technique and a gradient vector flow active contours algorithm to achieve an online tracking of the malleus under endoscopic vision, to guide the working channel to move efficiently during the surgery. The proposed method shows a more stable and accurate tracking performance than the current tracking methods in preclinical tests. With satisfactory tracking results, vision guidance of a suitable insertion spot can be provided to the device to perform the surgery in an automatic way. Copyright © 2015 John Wiley & Sons, Ltd.

  19. PRESBYOPIA OPTOMETRY METHOD BASED ON DIOPTER REGULATION AND CHARGE COUPLE DEVICE IMAGING TECHNOLOGY.

    PubMed

    Zhao, Q; Wu, X X; Zhou, J; Wang, X; Liu, R F; Gao, J

    2015-01-01

    With the development of photoelectric technology and single-chip microcomputer technology, objective optometry, also known as automatic optometry, is becoming precise. This paper proposed a presbyopia optometry method based on diopter regulation and Charge Couple Device (CCD) imaging technology and, in the meantime, designed a light path that could measure the system. This method projects a test figure to the eye ground and then the reflected image from the eye ground is detected by CCD. The image is then automatically identified by computer and the far point and near point diopters are determined to calculate lens parameter. This is a fully automatic objective optometry method which eliminates subjective factors of the tested subject. Furthermore, it can acquire the lens parameter of presbyopia accurately and quickly and can be used to measure the lens parameter of hyperopia, myopia and astigmatism.

  20. [Development of an automatic vacuum liquid chromatographic device and its application in the separation of the components from Schisandra chinensis (Turz) Baill].

    PubMed

    Zhu, Jingbo; Liu, Baoyue; Shan, Shibo; Ding, Yanl; Kou, Zinong; Xiao, Wei

    2015-08-01

    In order to meet the needs of efficient purification of products from natural resources, this paper developed an automatic vacuum liquid chromatographic device (AUTO-VLC) and applied it to the component separation of petroleum ether extracts of Schisandra chinensis (Turcz) Baill. The device was comprised of a solvent system, a 10-position distribution valve, a 3-position changes valve, dynamic axis compress chromatographic columns with three diameters, and a 10-position fraction valve. The programmable logic controller (PLC) S7- 200 was adopted to realize the automatic control and monitoring of the mobile phase changing, column selection, separation time setting and fraction collection. The separation results showed that six fractions (S1-S6) of different chemical components from 100 g Schisandra chinensis (Turcz) Baill. petroleum ether phase were obtained by the AUTO-VLC with 150 mm diameter dynamic axis compress chromatographic column. A new method used for the VLC separation parameters screened by using multiple development TLC was developed and confirmed. The initial mobile phase of AUTO-VLC was selected by taking Rf of all the target compounds ranging from 0 to 0.45 for fist development on the TLC; gradient elution ratio was selected according to k value (the slope of the linear function of Rf value and development times on the TLC) and the resolution of target compounds; elution times (n) were calculated by the formula n ≈ ΔRf/k. A total of four compounds with the purity more than 85% and 13 other components were separated from S5 under the selected conditions for only 17 h. Therefore, the development of the automatic VLC and its method are significant to the automatic and systematic separation of traditional Chinese medicines.

  1. Over-the-counter medicines

    MedlinePlus

    ... throat lozenges can be soothing. Be careful in young children because of the choking risk. ALLERGIES Antihistamine pills and liquids work well for treating allergy symptoms . Antihistamines that may ...

  2. Safety syringes and anti-needlestick devices in orthopaedic surgery.

    PubMed

    Sibbitt, Wilmer L; Band, Philip A; Kettwich, Lawrence G; Sibbitt, Cristina R; Sibbitt, Lori J; Bankhurst, Arthur D

    2011-09-07

    The American Academy of Orthopaedic Surgery (AAOS), The Joint Commission, the Occupational Safety and Health Administration (OSHA), and the Needlestick Safety and Prevention Act encourage the integration of safety-engineered devices to prevent needlestick injuries to health-care workers and patients. We hypothesized that safety syringes and needles could be used in outpatient orthopaedic injection and aspiration procedures. The study investigated the orthopaedic uses and procedural idiosyncrasies of safety-engineered devices, including (1) four safety needles (Eclipse, SafetyGlide, SurGuard, and Magellan), (2) a mechanical safety syringe (RPD), (3) two automatic retractable syringes (Integra, VanishPoint), (4) three manual retractable syringes (Procedur-SF, Baksnap, Invirosnap), and (5) three shielded syringes (Safety-Lok, Monoject, and Digitally Activated Shielded [DAS] Syringe). The devices were first tested ex vivo, and then 1300 devices were used for 425 subjects undergoing outpatient arthrocentesis, intra-articular injections, local anesthesia, aspiration biopsy, and ultrasound-guided procedures. During the clinical observation, there were no accidental needlesticks (0 needlesticks per 1300 devices). Safety needles could be successfully used on a Luer syringe but were limited to ≤1.5 in (≤3.81 cm) in length and the shield could interfere with sonography. The mechanical safety syringes functioned well in all orthopaedic procedures. Automatic retractable syringes were too small for arthrocentesis of the knee, and the plunger blew out and prematurely collapsed with high-pressure injections. The manual retractable syringes and shielded syringes could be used with conventional needles for most orthopaedic procedures. The most effective and reliable safety devices for orthopaedic syringe procedures are shielded safety needles, mechanical syringes, manual retractable syringes, and shielded syringes, but not automatic retractable syringes. Even when adopting safety-engineered devices for an orthopaedic clinic, conventional syringes larger than 20 mL and conventional needles longer than 1.5 in (3.8 cm) are necessary.

  3. 49 CFR 236.730 - Coil, receiver.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.730 Coil, receiver. Concentric layers of insulated wire wound around the core of a receiver of an automatic train stop, train control or cab signal device on a locomotive. ...

  4. Automatic bio-sample bacteria detection system

    NASA Technical Reports Server (NTRS)

    Chappelle, E. W.; Colburn, M.; Kelbaugh, B. N.; Picciolo, G. L.

    1971-01-01

    Electromechanical device analyzes urine specimens in 15 minutes and processes one sample per minute. Instrument utilizes bioluminescent reaction between luciferase-luciferin mixture and adenosine triphosphate (ATP) to determine number of bacteria present in the sample. Device has potential application to analysis of other body fluids.

  5. A method of automatic control procedures cardiopulmonary resuscitation

    NASA Astrophysics Data System (ADS)

    Bureev, A. Sh.; Zhdanov, D. S.; Kiseleva, E. Yu.; Kutsov, M. S.; Trifonov, A. Yu.

    2015-11-01

    The study is to present the results of works on creation of methods of automatic control procedures of cardiopulmonary resuscitation (CPR). A method of automatic control procedure of CPR by evaluating the acoustic data of the dynamics of blood flow in the bifurcation of carotid arteries and the dynamics of air flow in a trachea according to the current guidelines for CPR is presented. Evaluation of the patient is carried out by analyzing the respiratory noise and blood flow in the interspaces between the chest compressions and artificial pulmonary ventilation. The device operation algorithm of automatic control procedures of CPR and its block diagram has been developed.

  6. Randomized in vitro and in vivo evaluation of different biopsy needles and devices for breast biopsy.

    PubMed

    Helbich, T H; Rudas, M; Böhm, G; Huber, S; Wagner, T; Taucher, S; Wolf, G; Mostbeck, G H

    1999-01-01

    In an experimental study (in vitro and in vivo) we evaluated the efficacy of various biopsy needles/devices for breast biopsy. In vitro, biopsies of five human cadaveric breast specimens were performed using 33 different needles/devices ranging from 14 to 20-gauge. Of these 33 needles/devices, 22 optimally performing needles were selected for the in vivo study. In the clinical part of the study, 44 breast lesions were randomly biopsied with each of the 22 needles/devices under stereotactic guidance. Tissue specimens were analysed quantitatively and qualitatively. Several automatic long-throw guns (Acecut, Asap, Biopty, Magnum) obtained greater tissue areas and had a better histopathologic score than the conventional type of a side-notch needle like Trucut, an aspiration needle like Surecut, or an end-cut needle like Autovac. The automatic long-throw guns performed better than the short-throw Monopty gun. Regardless of needle size (14-20-gauge), breast biopsies should be routinely performed with automated long-throw side-notch guns (Acecut, Asap, Biopty, Magnum).

  7. A Low Cost Device for Monitoring the Urine Output of Critical Care Patients

    PubMed Central

    Otero, Abraham; Palacios, Francisco; Akinfiev, Teodor; Apalkov, Andrey

    2010-01-01

    In critical care units most of the patients’ physiological parameters are sensed by commercial monitoring devices. These devices can also supervise whether the values of the parameters lie within a pre-established range set by the clinician. The automation of the sensing and supervision tasks has discharged the healthcare staff of a considerable workload and avoids human errors, which are common in repetitive and monotonous tasks. Urine output is very likely the most relevant physiological parameter that has yet to be sensed or supervised automatically. This paper presents a low cost patent-pending device capable of sensing and supervising urine output. The device uses reed switches activated by a magnetic float in order to measure the amount of urine collected in two containers which are arranged in cascade. When either of the containers fills, it is emptied automatically using a siphon mechanism and urine begins to collect again. An electronic unit sends the state of the reed switches via Bluetooth to a PC that calculates the urine output from this information and supervises the achievement of therapeutic goals. PMID:22163495

  8. A low cost device for monitoring the urine output of critical care patients.

    PubMed

    Otero, Abraham; Palacios, Francisco; Akinfiev, Teodor; Apalkov, Andrey

    2010-01-01

    In critical care units most of the patients' physiological parameters are sensed by commercial monitoring devices. These devices can also supervise whether the values of the parameters lie within a pre-established range set by the clinician. The automation of the sensing and supervision tasks has discharged the healthcare staff of a considerable workload and avoids human errors, which are common in repetitive and monotonous tasks. Urine output is very likely the most relevant physiological parameter that has yet to be sensed or supervised automatically. This paper presents a low cost patent-pending device capable of sensing and supervising urine output. The device uses reed switches activated by a magnetic float in order to measure the amount of urine collected in two containers which are arranged in cascade. When either of the containers fills, it is emptied automatically using a siphon mechanism and urine begins to collect again. An electronic unit sends the state of the reed switches via Bluetooth to a PC that calculates the urine output from this information and supervises the achievement of therapeutic goals.

  9. 49 CFR 178.338-11 - Discharge control devices.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... water capacity, remote means of automatic closure must be installed at the ends of the cargo tank in at... control system. (ii) On a cargo tank motor vehicle of 3,500 gallons water capacity or less, at least one remote means of automatic closure must be installed on the end of the cargo tank farthest away from the...

  10. 49 CFR 236.566 - Locomotive of each train operating in train stop, train control or cab signal territory; equipped.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and... controlled, of each train operating in automatic train stop, train control, or cab signal territory shall be..., train control or cab signal territory; equipped. 236.566 Section 236.566 Transportation Other...

  11. 49 CFR 236.566 - Locomotive of each train operating in train stop, train control or cab signal territory; equipped.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and... controlled, of each train operating in automatic train stop, train control, or cab signal territory shall be..., train control or cab signal territory; equipped. 236.566 Section 236.566 Transportation Other...

  12. A Dual-Range Strain Gage Weighing Transducer Employing Automatic Switching

    Treesearch

    Rodger A. Arola

    1968-01-01

    Describes a dual-range strain gage transducer which has proven to be an excellent weight-sensing device for weighing trees and tree-length logs; discusses basic principals of the design and operation; and shows that a single transducer having two sensitivity ranges with automatic internal switching can sense weight with good repeatability and that one calibration curve...

  13. Automatic visual inspection system for microelectronics

    NASA Technical Reports Server (NTRS)

    Micka, E. Z. (Inventor)

    1975-01-01

    A system for automatically inspecting an integrated circuit was developed. A device for shining a scanning narrow light beam at an integrated circuit to be inspected and another light beam at an accepted integrated circuit was included. A pair of photodetectors that receive light reflected from these integrated circuits, and a comparing system compares the outputs of the photodetectors.

  14. 47 CFR 80.80 - Operating controls for ship stations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-162 MHz bands, reducing power output to one watt or less in accordance with § 80.215(e). 1 1 Ship... automatically reduce the carrier power to one watt or less when turned to the frequency 156.375 MHz or 156.650..., 1997, must automatically reduce power as described above. A manual override device must be provided...

  15. Impact of favorite stimuli automatically delivered on step responses of persons with multiple disabilities during their use of walker devices.

    PubMed

    Lancioni, Giulio E; Singh, Nirbhay N; O'Reilly, Mark F; Campodonico, Francesca; Piazzolla, Giorgia; Scalini, Lorenza; Oliva, Doretta

    2005-01-01

    Favorite stimuli were automatically delivered contingent on the performance of steps by two persons (a boy and a woman) with multiple disabilities during their use of support walker devices. The study lasted about 4 months and was carried out according to a multiple baseline design across participants. Recording concerned the participants' frequencies of steps and their indices of happiness during baseline and intervention sessions. Data showed that both participants had a significant increase in each of these two measures during the intervention phase. Implications of the findings and new research issues are discussed.

  16. 49 CFR 236.567 - Restrictions imposed when device fails and/or is cut out en route.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... cut out en route. 236.567 Section 236.567 Transportation Other Regulations Relating to Transportation...; Locomotives § 236.567 Restrictions imposed when device fails and/or is cut out en route. Where an automatic train stop, train control, or cab signal device fails and/or is cut out enroute, train may proceed at...

  17. Application of automatic threshold in dynamic target recognition with low contrast

    NASA Astrophysics Data System (ADS)

    Miao, Hua; Guo, Xiaoming; Chen, Yu

    2014-11-01

    Hybrid photoelectric joint transform correlator can realize automatic real-time recognition with high precision through the combination of optical devices and electronic devices. When recognizing targets with low contrast using photoelectric joint transform correlator, because of the difference of attitude, brightness and grayscale between target and template, only four to five frames of dynamic targets can be recognized without any processing. CCD camera is used to capture the dynamic target images and the capturing speed of CCD is 25 frames per second. Automatic threshold has many advantages like fast processing speed, effectively shielding noise interference, enhancing diffraction energy of useful information and better reserving outline of target and template, so this method plays a very important role in target recognition with optical correlation method. However, the automatic obtained threshold by program can not achieve the best recognition results for dynamic targets. The reason is that outline information is broken to some extent. Optimal threshold is obtained by manual intervention in most cases. Aiming at the characteristics of dynamic targets, the processing program of improved automatic threshold is finished by multiplying OTSU threshold of target and template by scale coefficient of the processed image, and combining with mathematical morphology. The optimal threshold can be achieved automatically by improved automatic threshold processing for dynamic low contrast target images. The recognition rate of dynamic targets is improved through decreased background noise effect and increased correlation information. A series of dynamic tank images with the speed about 70 km/h are adapted as target images. The 1st frame of this series of tanks can correlate only with the 3rd frame without any processing. Through OTSU threshold, the 80th frame can be recognized. By automatic threshold processing of the joint images, this number can be increased to 89 frames. Experimental results show that the improved automatic threshold processing has special application value for the recognition of dynamic target with low contrast.

  18. Fatal Asphyxiation in Bottlenose Dolphins (Tursiops truncatus) from the Indian River Lagoon.

    PubMed

    Stolen, Megan; St Leger, Judy; Durden, Wendy Noke; Mazza, Teresa; Nilson, Erika

    2013-01-01

    Multiple single case reports of asphyxiation in dolphins caused by fish lodged in the esophagus exist. However, the significance of this cause of mortality in a single population has not been documented. We performed a retrospective evaluation of pathology records from stranded bottlenose dolphins (Tursiops truncatus) from the Indian River Lagoon to evaluate the impact of this cause of death on this population. From 1997 to 2011, asphyxiation due to choking was identified as the cause of death in 14 of 350 cases (4%). Sampling of an unrelated but adjacent population over this same period yielded 186 necropsy cases of bottlenose dolphins with no cases of asphyxiation. Asphyxiated animals presented with a fish lodged in the cranial esophagus associated with a dislocated and obstructed or compressed larynx. There was no clear sex predilection. Affected animals included 12 adults and two juveniles. The fish species involved included sheepshead, black chin tilapia and striped mojarra. In five cases, recreational fishing gear was also present. Cetacean choking is related to selection of prey fish species with strong dorsal spines and may be secondarily associated with fish attached to fishing gear. Prey abundance and dolphin behavior may influence these selections. Environmental alterations leading to changes in prey availability or increased interactions with fishing gear may change the significance of fatal choking in dolphin populations.

  19. Meanline Analysis of Turbines with Choked Flow in the Object-Oriented Turbomachinery Analysis Code

    NASA Technical Reports Server (NTRS)

    Hendricks, Eric S.

    2016-01-01

    The prediction of turbomachinery performance characteristics is an important part of the conceptual aircraft engine design process. During this phase, the designer must examine the effects of a large number of turbomachinery design parameters to determine their impact on overall engine performance and weight. The lack of detailed design information available in this phase necessitates the use of simpler meanline and streamline methods to determine the turbomachinery geometry characteristics and provide performance estimates prior to more detailed CFD (Computational Fluid Dynamics) analyses. While a number of analysis codes have been developed for this purpose, most are written in outdated software languages and may be difficult or impossible to apply to new, unconventional designs. The Object-Oriented Turbomachinery Analysis Code (OTAC) is currently being developed at NASA Glenn Research Center to provide a flexible meanline and streamline analysis capability in a modern object-oriented language. During the development and validation of OTAC, a limitation was identified in the code's ability to analyze and converge turbines as the flow approached choking. This paper describes a series of changes which can be made to typical OTAC turbine meanline models to enable the assessment of choked flow up to limit load conditions. Results produced with this revised model setup are provided in the form of turbine performance maps and are compared to published maps.

  20. High sensitivity measurement system for the direct-current, capacitance-voltage, and gate-drain low frequency noise characterization of field effect transistors.

    PubMed

    Giusi, G; Giordano, O; Scandurra, G; Rapisarda, M; Calvi, S; Ciofi, C

    2016-04-01

    Measurements of current fluctuations originating in electron devices have been largely used to understand the electrical properties of materials and ultimate device performances. In this work, we propose a high-sensitivity measurement setup topology suitable for the automatic and programmable Direct-Current (DC), Capacitance-Voltage (CV), and gate-drain low frequency noise characterization of field effect transistors at wafer level. Automatic and programmable operation is particularly useful when the device characteristics relax or degrade with time due to optical, bias, or temperature stress. The noise sensitivity of the proposed topology is in the order of fA/Hz(1/2), while DC performances are limited only by the source and measurement units used to bias the device under test. DC, CV, and NOISE measurements, down to 1 pA of DC gate and drain bias currents, in organic thin film transistors are reported to demonstrate system operation and performances.

  1. High sensitivity measurement system for the direct-current, capacitance-voltage, and gate-drain low frequency noise characterization of field effect transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giusi, G.; Giordano, O.; Scandurra, G.

    Measurements of current fluctuations originating in electron devices have been largely used to understand the electrical properties of materials and ultimate device performances. In this work, we propose a high-sensitivity measurement setup topology suitable for the automatic and programmable Direct-Current (DC), Capacitance-Voltage (CV), and gate-drain low frequency noise characterization of field effect transistors at wafer level. Automatic and programmable operation is particularly useful when the device characteristics relax or degrade with time due to optical, bias, or temperature stress. The noise sensitivity of the proposed topology is in the order of fA/Hz{sup 1/2}, while DC performances are limited only bymore » the source and measurement units used to bias the device under test. DC, CV, and NOISE measurements, down to 1 pA of DC gate and drain bias currents, in organic thin film transistors are reported to demonstrate system operation and performances.« less

  2. 75 FR 56113 - Notice of Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-15

    ... with the CMHS Designated Federal Official (DFO), Ms. Carol Watkins (see contact information below) to...: Carol Watkins, Designated Federal Official, CMHS National Advisory Council, 1 Choke Cherry Road, Room 6...

  3. Investigation of turbines for driving supersonic compressors II : performance of first configuration with 2.2 percent reduction in nozzle flow area / Warner L. Stewart, Harold J. Schum, Robert Y. Wong

    NASA Technical Reports Server (NTRS)

    Stewart, Warner L; Schum, Harold J; Wong, Robert Y

    1952-01-01

    The experimental performance of a modified turbine for driving a supersonic compressor is presented and compared with the performance of the original configuration to illustrate the effect of small changes in the ratio of nozzle-throat area to rotor-throat area. Performance is based on the performance of turbines designed to operate with both blade rows close to choking. On the basis of the results of this investigation, the ratio of areas is concluded to become especially critical in the design of turbines such as those designed to drive high-speed, high-specific weight-flow compressors where the turbine nozzles and rotor are both very close to choking.

  4. Geodetic antenna calibration test in the Antarctic environment

    USGS Publications Warehouse

    Grejner-Brzezinska, A.; Vazquez, E.; Hothem, L.

    2006-01-01

    TransAntarctic Mountain DEFormation (TAMDEF) Monitoring Network is the NSF-sponsored OSU and USGS project, aimed at measuring crustal motion in the Transantarctic Mountains of Victoria Land using GPS carrier phase measurements. Station monumentation, antenna mounts, antenna types, and data processing strategies were optimized to achieve mm-level estimates for the rates of motion. These data contributes also to regional Antarctic frame definition. Significant amount of data collected over several years allow the investigation of unique aspects of GPS geodesy in Antarctica, to determine how the error spectrum compares to the mid-latitude regions, and to identify the optimum measurement and data processing schemes for Antarctic conditions, in order to test the predicted rates of motion (mm-level w.r.t. time). The data collection for the TAMDEF project was initiated in 1996. The primary antenna used has been the Ashtech L1/L2 Dorne Margolin (D/M) choke ring. A few occupations involved the use of a Trimble D/M choke ring. The data were processed using the antenna calibration data available from the National Geodetic Survey (NGS). The recent developments in new antenna designs that are lighter in weight and lower in cost are being considered as a possible alternative to the bulkier and more expensive D/M choke ring design. In November 2003, in situ testing of three alternative models of L1/L2 antennas was conducted at a site located in the vicinity of McMurdo Station, Antarctica (S77.87, E166.56). The antenna models used in this test were: Ashtech D/M choke ring, Trimble D/M choke ring, Trimble Zephyr, and the NovAtel GPS-702. Two stations, spaced within 30 meters, were used in the test. Both had the characteristics similar to the stations of the TAMDEF network, i.e., the UNAVCO fixed-height, force-centered level mounts with a constant antenna offset were used, ensuring extreme stability of the antenna/ mount/pin set up. During each of the four 3-day test data collection sessions, a reference station was occupied continuously with the Ashtech D/M choke ring antenna, while the second station was occupied by the tested antennas, one 3-day session for each antenna type. The coordinate differences were produced using software optimized for the analysis of data collected over short baselines. Each solution incorporated the NGS antenna calibration data appropriate for each antenna model. Hourly and 24-hour solutions were analyzed for repeatability and compared to the standard baseline coordinate differences. No significant variation was observed when comparing the same type of antennas and when switching antennas at the test site using daily solutions. An mm-level scatter can be observed comparing different antennas over the 1-hour solutions; it is smaller for the horizontal components, as compared to the vertical direction. At this point, it can be concluded that the standard antenna calibration models from NGS used for each antenna involved in this test did not result in any significant variation in the daily results, but with some in the hourly results. Thus, based on this fact, the antenna types tested here could be used in the future TAMDEF campaigns, where 24-hour solutions are normally used for deformation monitoring. These results can serve as good guidance to any future use of GPS equipment in Antarctica.

  5. Development of a microcontroller-based automatic control system for the electrohydraulic total artificial heart.

    PubMed

    Kim, H C; Khanwilkar, P S; Bearnson, G B; Olsen, D B

    1997-01-01

    An automatic physiological control system for the actively filled, alternately pumped ventricles of the volumetrically coupled, electrohydraulic total artificial heart (EHTAH) was developed for long-term use. The automatic control system must ensure that the device: 1) maintains a physiological response of cardiac output, 2) compensates for an nonphysiological condition, and 3) is stable, reliable, and operates at a high power efficiency. The developed automatic control system met these requirements both in vitro, in week-long continuous mock circulation tests, and in vivo, in acute open-chested animals (calves). Satisfactory results were also obtained in a series of chronic animal experiments, including 21 days of continuous operation of the fully automatic control mode, and 138 days of operation in a manual mode, in a 159-day calf implant.

  6. Semiconductor technology program: Progress briefs

    NASA Technical Reports Server (NTRS)

    Galloway, K. F.; Scace, R. I.; Walters, E. J.

    1981-01-01

    Measurement technology for semiconductor materials, process control, and devices, is discussed. Silicon and silicon based devices are emphasized. Highlighted activities include semiinsulating GaAs characterization, an automatic scanning spectroscopic ellipsometer, linewidth measurement and coherence, bandgap narrowing effects in silicon, the evaluation of electrical linewidth uniformity, and arsenicomplanted profiles in silicon.

  7. 21 CFR 820.200 - Servicing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... reports with appropriate statistical methodology in accordance with § 820.100. (c) Each manufacturer who... chapter shall automatically consider the report a complaint and shall process it in accordance with the... device serviced; (2) Any device identification(s) and control number(s) used; (3) The date of service; (4...

  8. AUTOMATIC COUNTING APPARATUS

    DOEpatents

    Howell, W.D.

    1957-08-20

    An apparatus for automatically recording the results of counting operations on trains of electrical pulses is described. The disadvantages of prior devices utilizing the two common methods of obtaining the count rate are overcome by this apparatus; in the case of time controlled operation, the disclosed system automatically records amy information stored by the scaler but not transferred to the printer at the end of the predetermined time controlled operations and, in the case of count controlled operation, provision is made to prevent a weak sample from occupying the apparatus for an excessively long period of time.

  9. Automatized alignment control of wing mechanization in aerodynamic contour of aircraft

    NASA Astrophysics Data System (ADS)

    Odnokurtsev, K. A.

    2018-05-01

    The method of automatized control of accuracy of an aircraft aerodynamic contour when mounting wing mechanization elements is described in the article. A control device in the stand of the wing assembling, equipped with the distance sensors, is suggested to be used. The measurement of control points’ inaccuracies is made automatically in a special computer program. Two kinds of sensor calibration are made in advance in order to increase the accuracy of measurements. As a result, the duration of control and adjustment of mechanization elements is reduced.

  10. Preliminary Two-Phase Terry Turbine Nozzle Models for RCIC Off-Design Operation Conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Haihua; O'Brien, James

    This report presents the effort to extend the single-phase analytical Terry turbine model to cover two-phase off-design conditions. The work includes: (1) adding well-established two-phase choking models – the Isentropic Homogenous Equilibrium Model (IHEM) and Moody’s model, and (2) theoretical development and implementation of a two-phase nozzle expansion model. The two choking models provide bounding cases for the two-phase choking mass flow rate. The new two-phase Terry turbine model uses the choking models to calculate the mass flow rate, the critical pressure at the nozzle throat, and steam quality. In the divergent stage, we only consider the vapor phase withmore » a similar model for the single-phase case by assuming that the liquid phase would slip along the wall with a much slower speed and will not contribute the impulse on the rotor. We also modify the stagnation conditions according to two-phase choking conditions at the throat and the cross-section areas for steam flow at the nozzle throat and at the nozzle exit. The new two-phase Terry turbine model was benchmarked with the same steam nozzle test as for the single-phase model. Better agreement with the experimental data is observed than from the single-phase model. We also repeated the Terry turbine nozzle benchmark work against the Sandia CFD simulation results with the two-phase model for the pure steam inlet nozzle case. The RCIC start-up tests were simulated and compared with the single-phase model. Similar results are obtained. Finally, we designed a new RCIC system test case to simulate the self-regulated Terry turbine behavior observed in Fukushima accidents. In this test, a period inlet condition for the steam quality varying from 1 to 0 is applied. For the high quality inlet period, the RCIC system behaves just like the normal operation condition with a high pump injection flow rate and a nominal steam release rate through the turbine, with the net addition of water to the primary system; for the low quality inlet period, the RCIC turbine shaft work dramatically decreases and results in a much reduced pump injection flow rate, and the mixture flow rate through the turbine increases due to the high liquid phase flow rate. The net effect for this period is net removal of coolant from the primary loop. With the periodic addition and removal of coolant to the primary loop, the self-regulation mode of the RCIC system can be maintained for a quite long time. Both the IHEM and Moody’s models generate similar phenomena; however noticeable differences can be observed.« less

  11. Assisting People with Developmental Disabilities to Improve Computer Pointing Efficiency through Multiple Mice and Automatic Pointing Assistive Programs

    ERIC Educational Resources Information Center

    Shih, Ching-Hsiang

    2011-01-01

    This study combines multi-mice technology (people with disabilities can use standard mice, instead of specialized alternative computer input devices, to achieve complete mouse operation) with an assistive pointing function (i.e. cursor-capturing, which enables the user to move the cursor to the target center automatically), to assess whether two…

  12. Mobile Genome Express (MGE): A comprehensive automatic genetic analyses pipeline with a mobile device.

    PubMed

    Yoon, Jun-Hee; Kim, Thomas W; Mendez, Pedro; Jablons, David M; Kim, Il-Jin

    2017-01-01

    The development of next-generation sequencing (NGS) technology allows to sequence whole exomes or genome. However, data analysis is still the biggest bottleneck for its wide implementation. Most laboratories still depend on manual procedures for data handling and analyses, which translates into a delay and decreased efficiency in the delivery of NGS results to doctors and patients. Thus, there is high demand for developing an automatic and an easy-to-use NGS data analyses system. We developed comprehensive, automatic genetic analyses controller named Mobile Genome Express (MGE) that works in smartphones or other mobile devices. MGE can handle all the steps for genetic analyses, such as: sample information submission, sequencing run quality check from the sequencer, secured data transfer and results review. We sequenced an Actrometrix control DNA containing multiple proven human mutations using a targeted sequencing panel, and the whole analysis was managed by MGE, and its data reviewing program called ELECTRO. All steps were processed automatically except for the final sequencing review procedure with ELECTRO to confirm mutations. The data analysis process was completed within several hours. We confirmed the mutations that we have identified were consistent with our previous results obtained by using multi-step, manual pipelines.

  13. 30 CFR 57.22202 - Main fans (I-A, I-B, I-C, II-A, III, V-A, and V-B mines).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... mines, provided with an automatic signal device to give an alarm when the fan stops. The signal device... possible explosive forces; (2) Equipped with explosion-doors, a weak-wall, or other equivalent devices... or weak-wall shall be at least equivalent to the average cross-sectional area of the airway. (c) (1...

  14. 30 CFR 57.22202 - Main fans (I-A, I-B, I-C, II-A, III, V-A, and V-B mines).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... mines, provided with an automatic signal device to give an alarm when the fan stops. The signal device... possible explosive forces; (2) Equipped with explosion-doors, a weak-wall, or other equivalent devices... or weak-wall shall be at least equivalent to the average cross-sectional area of the airway. (c) (1...

  15. 30 CFR 57.22202 - Main fans (I-A, I-B, I-C, II-A, III, V-A, and V-B mines).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... mines, provided with an automatic signal device to give an alarm when the fan stops. The signal device... possible explosive forces; (2) Equipped with explosion-doors, a weak-wall, or other equivalent devices... or weak-wall shall be at least equivalent to the average cross-sectional area of the airway. (c) (1...

  16. 30 CFR 57.22202 - Main fans (I-A, I-B, I-C, II-A, III, V-A, and V-B mines).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... mines, provided with an automatic signal device to give an alarm when the fan stops. The signal device... possible explosive forces; (2) Equipped with explosion-doors, a weak-wall, or other equivalent devices... or weak-wall shall be at least equivalent to the average cross-sectional area of the airway. (c) (1...

  17. Realization of the ergonomics design and automatic control of the fundus cameras

    NASA Astrophysics Data System (ADS)

    Zeng, Chi-liang; Xiao, Ze-xin; Deng, Shi-chao; Yu, Xin-ye

    2012-12-01

    The principles of ergonomics design in fundus cameras should be extending the agreeableness by automatic control. Firstly, a 3D positional numerical control system is designed for positioning the eye pupils of the patients who are doing fundus examinations. This system consists of a electronically controlled chin bracket for moving up and down, a lateral movement of binocular with the detector and the automatic refocusing of the edges of the eye pupils. Secondly, an auto-focusing device for the object plane of patient's fundus is designed, which collects the patient's fundus images automatically whether their eyes is ametropic or not. Finally, a moving visual target is developed for expanding the fields of the fundus images.

  18. A VxD-based automatic blending system using multithreaded programming.

    PubMed

    Wang, L; Jiang, X; Chen, Y; Tan, K C

    2004-01-01

    This paper discusses the object-oriented software design for an automatic blending system. By combining the advantages of a programmable logic controller (PLC) and an industrial control PC (ICPC), an automatic blending control system is developed for a chemical plant. The system structure and multithread-based communication approach are first presented in this paper. The overall software design issues, such as system requirements and functionalities, are then discussed in detail. Furthermore, by replacing the conventional dynamic link library (DLL) with virtual X device drivers (VxD's), a practical and cost-effective solution is provided to improve the robustness of the Windows platform-based automatic blending system in small- and medium-sized plants.

  19. Automatic microbial transfer

    NASA Technical Reports Server (NTRS)

    Wilkins, J. R.; Mills, S. M.

    1973-01-01

    Device can transfer metabolites or inhibitory agents to broth cultures of bacteria, in various stages of growth, for study. It also has application in transfer of other micro-organisms, such as yeasts, and could be useful in clinical and research laboratories. Device has been used for wide variety of purposes in experimental situations.

  20. 30 CFR 77.600 - Trailing cables; short-circuit protection; disconnecting devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cables; short-circuit protection... AREAS OF UNDERGROUND COAL MINES Trailing Cables § 77.600 Trailing cables; short-circuit protection; disconnecting devices. Short-circuit protection for trailing cables shall be provided by an automatic circuit...

  1. 30 CFR 18.53 - High-voltage longwall mining systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and Design Requirements § 18.53 High-voltage longwall mining systems. (a) In each high-voltage motor...-interrupting devices must be designed and installed to prevent automatic reclosure. (d) Transformers with high... “open” position; (iv) When located in an explosion-proof enclosure, the device must be designed and...

  2. 30 CFR 18.53 - High-voltage longwall mining systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and Design Requirements § 18.53 High-voltage longwall mining systems. (a) In each high-voltage motor...-interrupting devices must be designed and installed to prevent automatic reclosure. (d) Transformers with high... “open” position; (iv) When located in an explosion-proof enclosure, the device must be designed and...

  3. 30 CFR 18.53 - High-voltage longwall mining systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and Design Requirements § 18.53 High-voltage longwall mining systems. (a) In each high-voltage motor...-interrupting devices must be designed and installed to prevent automatic reclosure. (d) Transformers with high... “open” position; (iv) When located in an explosion-proof enclosure, the device must be designed and...

  4. 30 CFR 18.53 - High-voltage longwall mining systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and Design Requirements § 18.53 High-voltage longwall mining systems. (a) In each high-voltage motor...-interrupting devices must be designed and installed to prevent automatic reclosure. (d) Transformers with high... “open” position; (iv) When located in an explosion-proof enclosure, the device must be designed and...

  5. 30 CFR 18.53 - High-voltage longwall mining systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and Design Requirements § 18.53 High-voltage longwall mining systems. (a) In each high-voltage motor...-interrupting devices must be designed and installed to prevent automatic reclosure. (d) Transformers with high... “open” position; (iv) When located in an explosion-proof enclosure, the device must be designed and...

  6. 49 CFR 236.553 - Seal, where required.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Locomotives § 236.553 Seal, where required. Seal shall be maintained on any device other than brake-pipe cut-out cock (double-heading cock), by...

  7. 49 CFR 236.553 - Seal, where required.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Locomotives § 236.553 Seal, where required. Seal shall be maintained on any device other than brake-pipe cut-out cock (double-heading cock), by...

  8. 49 CFR 236.567 - Restrictions imposed when device fails and/or is cut out en route.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... cut out en route. 236.567 Section 236.567 Transportation Other Regulations Relating to Transportation... GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions...

  9. 49 CFR 395.15 - Automatic on-board recording devices.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... information concerning on-board system sensor failures and identification of edited data. Such support systems... driving today; (iv) Total hours on duty for the 7 consecutive day period, including today; (v) Total hours...-driver operation; (7) The on-board recording device/system identifies sensor failures and edited data...

  10. 9 CFR 307.7 - Safety requirements for electrical stimulating (EST) equipment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... beam sensors form the enclosure, the stimulating equipment shall be automatically shut off when the sensor signals are broken. (3) Mandatory Warning Devices and Signals. The following warning devices or.... (ii) An ANSI Z53.1-Color Code sign reading (a) “Danger Electrical Hazard” for stimulating voltage...

  11. 9 CFR 307.7 - Safety requirements for electrical stimulating (EST) equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... beam sensors form the enclosure, the stimulating equipment shall be automatically shut off when the sensor signals are broken. (3) Mandatory Warning Devices and Signals. The following warning devices or.... (ii) An ANSI Z53.1-Color Code sign reading (a) “Danger Electrical Hazard” for stimulating voltage...

  12. Portable light detection system for the blind

    NASA Technical Reports Server (NTRS)

    Wilber, R. L.; Carpenter, B. L.

    1973-01-01

    System can be used to detect "ready" light on automatic cooking device, to tell if lights are on for visitors, or to tell whether it is daylight or dark outside. Device is actuated like flashlight. Light impinging on photo cell activates transistor which energizes buzzer to indicate presence of light.

  13. Curcumin-Combretastatin Nanocells as Breast Cancer Cytotoxic and Antiangiogenic Agent

    DTIC Science & Technology

    2008-09-01

    network of polyionic (e.g. polyethylenimine , polyacrylic acid, poly-L-lysine etc.) and neutral polymer chains (e.g. PEG, Pluronic/Poloxamer...devices were then mounted back to device stations placed inside a CO2 incubator. The CI was automatically monitored by the RT-CES system. The results

  14. Emergency escape system uses self-braking mechanism on fixed cable

    NASA Technical Reports Server (NTRS)

    Billings, C. R.; Mc Daris, R. A.; Mc Gough, J. T.; Neal, P. F.

    1966-01-01

    Slide-wire system with a twist level slide device incorporates automatic descent and braking for the safe and rapid evacuation of personnel from tall structures. This device is used on any tall structure that might require emergency evacuation. It is also used to transfer materials and equipment.

  15. Infant Choking: How to Keep Your Baby Safe

    MedlinePlus

    ... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization and proceeds from Web advertising help support our mission. Mayo Clinic does not ...

  16. Choosing Safe Toys

    MedlinePlus

    ... the throat above the windpipe and restrict breathing. Battery-operated toys should have battery cases that secure with screws so that kids cannot pry them open. Batteries and battery fluid pose serious risks, including choking, ...

  17. 78 FR 21891 - Rural Call Completion

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-12

    ... traffic may not be blocked, choked, reduced, or restricted, we have learned that carriers often do not... called party, including, for example, by voicemail, answering machine, or fax machine. We calculate a...

  18. Key Facts about Tularemia

    MedlinePlus

    ... Methyl isocyanate Case Definition: Methyl Isocyanate Poisoning Mustard gas (H) (sulfur mustard) Facts About Sulfur Mustard Case ... choking/lung agents Ricin Riot control agents/tear gas Facts About Riot Control Agents Case Definition: Riot ...

  19. Choking: First Aid

    MedlinePlus

    ... 2, 2017. Kleinman ME, et al. Part 5: Adult basic life support and cardiopulmonary resuscitation quality — 2015 American ... and Research. © 1998-2018 Mayo Foundation for Medical Education and Research (MFMER). All rights reserved.

  20. Development of medical electronic devices in the APL space department

    NASA Technical Reports Server (NTRS)

    Newman, A. L.

    1985-01-01

    Several electronic devices for automatically correcting specific defects in a body's physiologic regulation and allowing approximately normal functioning are described. A self-injurious behavior inhibiting system (SIBIS) is fastened to the arm of a person with chronic self-injurious behavior patterns. An electric shock is delivered into the arm whenever the device senses above-threshold acceleration of the head such as occur with head-bangers. Sounding a buzzer tone with the shock eventually allows transference of the aversive stimulus to the buzzer so shocks are no longer necessary. A programmable implantable medication system features a solenoid pump placed beneath the skin and refueled by hypodermic needle. The pump functions are programmable and can deliver insulin, chemotherapy mixes and/or pain killers according to a preset schedule or on patient demand. Finally, an automatic implantible defibrillator has four electrodes attached directly to the heart for sensing electrical impulses or emitting them in response to cardiac fibrillation.

  1. Redundant drive current imbalance problem of the Automatic Radiator Inspection Device (ARID)

    NASA Technical Reports Server (NTRS)

    Latino, Carl D.

    1992-01-01

    The Automatic Radiator Inspection Device (ARID) is a 4 Degree of Freedom (DOF) robot with redundant drive motors at each joint. The device is intended to automate the labor intensive task of space shuttle radiator inspection. For safety and redundancy, each joint is driven by two independent motor systems. Motors driving the same joint, however, draw vastly different currents. The concern was that the robot joints could be subjected to undue stress. It was the objective of this summer's project to determine the cause of this current imbalance. In addition it was to determine, in a quantitative manner, what was the cause, how serious the problem was in terms of damage or undue wear to the robot and find solutions if possible. It was concluded that most problems could be resolved with a better motor control design. This document discusses problems encountered and possible solutions.

  2. Visual perception system and method for a humanoid robot

    NASA Technical Reports Server (NTRS)

    Chelian, Suhas E. (Inventor); Linn, Douglas Martin (Inventor); Wampler, II, Charles W. (Inventor); Bridgwater, Lyndon (Inventor); Wells, James W. (Inventor); Mc Kay, Neil David (Inventor)

    2012-01-01

    A robotic system includes a humanoid robot with robotic joints each moveable using an actuator(s), and a distributed controller for controlling the movement of each of the robotic joints. The controller includes a visual perception module (VPM) for visually identifying and tracking an object in the field of view of the robot under threshold lighting conditions. The VPM includes optical devices for collecting an image of the object, a positional extraction device, and a host machine having an algorithm for processing the image and positional information. The algorithm visually identifies and tracks the object, and automatically adapts an exposure time of the optical devices to prevent feature data loss of the image under the threshold lighting conditions. A method of identifying and tracking the object includes collecting the image, extracting positional information of the object, and automatically adapting the exposure time to thereby prevent feature data loss of the image.

  3. Demountable damped cavity for HOM-damping in ILC superconducting accelerating cavities

    NASA Astrophysics Data System (ADS)

    Konomi, T.; Yasuda, F.; Furuta, F.; Saito, K.

    2014-01-01

    We have designed a new higher-order-mode (HOM) damper called a demountable damped cavity (DDC) as part of the R&D efforts for the superconducting cavity of the International Linear Collider (ILC). The DDC has two design concepts. The first is an axially symmetrical layout to obtain high damping efficiency. The DDC has a coaxial structure along the beam axis to realize strong coupling with HOMs. HOMs are damped by an RF absorber at the end of the coaxial waveguide and the accelerating mode is reflected by a choke filter mounted at the entrance of the coaxial waveguide. The second design concept is a demountable structure to facilitate cleaning, in order to suppress the Q-slope problem in a high field. A single-cell cavity with the DDC was fabricated to test four performance parameters. The first was frequency matching between the accelerating cavity and the choke filter. Since the bandwidth of the resonance frequency in a superconducting cavity is very narrow, there is a possibility that the accelerating field will leak to the RF absorber because of thermal shrinkage. The design bandwidth of the choke filter is 25 kHz. It was demonstrated that frequency matching adjusted at room temperature could be successfully maintained at 2 K. The second parameter was the performance of the demountable structure. At the joint, the magnetic field is 1/6 of the maximum field in the accelerating cavity. Ultimately, the accelerating field reached 19 MV/m and Q0 was 1.5×1010 with a knife-edge shape. The third parameter was field emission and multipacting. Although the choke structure has numerous parallel surfaces that are susceptible to the multipacting problem, it was found that neither field emission nor multipacting presented problems in both an experiment and simulation. The final parameter was the Q values of the HOM. The RF absorber adopted in the system is a Ni-Zn ferrite type. The RF absorber shape was designed based on the measurement data of permittivity and permeability at 77 K. The Q values of the HOM in the DDC are 10-100 times lower than those of a TESLA-type HOM coupler.

  4. Selected Aspects of the eCall Emergency Notification System

    NASA Astrophysics Data System (ADS)

    Kaminski, Tomasz; Nowacki, Gabriel; Mitraszewska, Izabella; Niezgoda, Michał; Kruszewski, Mikołaj; Kaminska, Ewa; Filipek, Przemysław

    2012-02-01

    The article describes problems associated with the road collision detection for the purpose of the automatic emergency call. At the moment collision is detected, the eCall device installed in the vehicle will automatically make contact with Emergency Notification Centre and send the set of essential information on the vehicle and the place of the accident. To activate the alarm, the information about the deployment of the airbags will not be used, because connection of the eCall device might interfere with the vehicle’s safety systems. It is necessary to develop a method enabling detection of the road collision, similar to the one used in airbag systems, and based on the signals available from the acceleration sensors.

  5. Electrical safety device

    DOEpatents

    White, David B.

    1991-01-01

    An electrical safety device for use in power tools that is designed to automatically discontinue operation of the power tool upon physical contact of the tool with a concealed conductive material. A step down transformer is used to supply the operating power for a disconnect relay and a reset relay. When physical contact is made between the power tool and the conductive material, an electrical circuit through the disconnect relay is completed and the operation of the power tool is automatically interrupted. Once the contact between the tool and conductive material is broken, the power tool can be quickly and easily reactivated by a reset push button activating the reset relay. A remote reset is provided for convenience and efficiency of operation.

  6. Recent results from the University of Washington's 38 mm ram accelerator

    NASA Technical Reports Server (NTRS)

    De Turenne, J. A.; Chew, G.; Bruckner, A. P.

    1992-01-01

    The ram accelerator is a propulsive device that accelerates projectiles using gasdynamic cycles similar to those which generate thrust in airbreathing ramjets. The projectile, analogous to the centerbody of a ramjet, travels supersonically through a stationary tube containing a gaseous fuel and oxidizer mixture. The projectile itself carries no onboard propellant. A combustion zone follows the projectile and stabilizes the shock structure. The resulting pressure distribution continuously accelerates the projectile. Several modes of ram accelerator operation have been investigated experimentally and theoretically. At velocities below the Chapman-Jouguet (C-J) detonation speed of the propellant mixture, the thermally choked propulsion mode accelerates the projectiles. At projectile velocities between approximately 90 and 110 percent of the C-J speed, a transdetonative propulsion mode occurs. At velocities beyond 110 percent of the C-J speed, projectiles experience superdetonative propulsion. This paper presents recent experimental results from these propulsion modes obtained with the University of Washington's 38-mm bore ram accelerator. Data from investigations with hydrogen diluted-gas mixtures are also introduced.

  7. Automatic portion estimation and visual refinement in mobile dietary assessment

    PubMed Central

    Woo, Insoo; Otsmo, Karl; Kim, SungYe; Ebert, David S.; Delp, Edward J.; Boushey, Carol J.

    2011-01-01

    As concern for obesity grows, the need for automated and accurate methods to monitor nutrient intake becomes essential as dietary intake provides a valuable basis for managing dietary imbalance. Moreover, as mobile devices with built-in cameras have become ubiquitous, one potential means of monitoring dietary intake is photographing meals using mobile devices and having an automatic estimate of the nutrient contents returned. One of the challenging problems of the image-based dietary assessment is the accurate estimation of food portion size from a photograph taken with a mobile digital camera. In this work, we describe a method to automatically calculate portion size of a variety of foods through volume estimation using an image. These “portion volumes” utilize camera parameter estimation and model reconstruction to determine the volume of food items, from which nutritional content is then extrapolated. In this paper, we describe our initial results of accuracy evaluation using real and simulated meal images and demonstrate the potential of our approach. PMID:22242198

  8. Automatic portion estimation and visual refinement in mobile dietary assessment

    NASA Astrophysics Data System (ADS)

    Woo, Insoo; Otsmo, Karl; Kim, SungYe; Ebert, David S.; Delp, Edward J.; Boushey, Carol J.

    2010-01-01

    As concern for obesity grows, the need for automated and accurate methods to monitor nutrient intake becomes essential as dietary intake provides a valuable basis for managing dietary imbalance. Moreover, as mobile devices with built-in cameras have become ubiquitous, one potential means of monitoring dietary intake is photographing meals using mobile devices and having an automatic estimate of the nutrient contents returned. One of the challenging problems of the image-based dietary assessment is the accurate estimation of food portion size from a photograph taken with a mobile digital camera. In this work, we describe a method to automatically calculate portion size of a variety of foods through volume estimation using an image. These "portion volumes" utilize camera parameter estimation and model reconstruction to determine the volume of food items, from which nutritional content is then extrapolated. In this paper, we describe our initial results of accuracy evaluation using real and simulated meal images and demonstrate the potential of our approach.

  9. First Aid: Choking

    MedlinePlus

    ... breathing, send someone to call 911 . Immediately perform cardiopulmonary resuscitation (CPR) if you've been trained. Take your child ... reach. Learn how to do abdominal thrusts and CPR, which usually are taught as part of any ...

  10. Choking and Strangulation Prevention Tips

    MedlinePlus

    ... away from children. These include magnets found in construction sets, children's toys or stress-relieving adult desk ... with Us Donate Join Our Mailing List Global Road Safety Sponsors Recalls Media Center Blog Videos Newsletter ...

  11. Choking first aid - infant under 1 year - slideshow

    MedlinePlus

    ... Duplication for commercial use must be authorized in writing by ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow us Disclaimers Copyright ...

  12. A device for testing cables

    NASA Technical Reports Server (NTRS)

    Hayhurst, Arthur Ray (Inventor)

    1993-01-01

    A device for testing current paths is attachable to a conductor. The device automatically checks the current paths of the conductor for continuity of a center conductor, continuity of a shield, and a short circuit between the shield and the center conductor. The device includes a pair of connectors and a circuit to provide for testing of the conductive paths of a cable to be tested with the circuit paths of the circuit. The circuit paths in the circuit include indicators to simultaneously indicate the results of the testing.

  13. Testing electroexplosive devices by programmed pulsing techniques

    NASA Technical Reports Server (NTRS)

    Rosenthal, L. A.; Menichelli, V. J.

    1976-01-01

    A novel method for testing electroexplosive devices is proposed wherein capacitor discharge pulses, with increasing energy in a step-wise fashion, are delivered to the device under test. The size of the energy increment can be programmed so that firing takes place after many, or after only a few, steps. The testing cycle is automatically terminated upon firing. An energy-firing contour relating the energy required to the programmed step size describes the single-pulse firing energy and the possible sensitization or desensitization of the explosive device.

  14. Automatic voltage imbalance detector

    DOEpatents

    Bobbett, Ronald E.; McCormick, J. Byron; Kerwin, William J.

    1984-01-01

    A device for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

  15. Geometry calibration for x-ray equipment in radiation treatment devices and estimation of remaining patient alignment errors

    NASA Astrophysics Data System (ADS)

    Selby, Boris P.; Sakas, Georgios; Walter, Stefan; Stilla, Uwe

    2008-03-01

    Positioning a patient accurately in treatment devices is crucial for radiological treatment, especially if accuracy vantages of particle beam treatment are exploited. To avoid sub-millimeter misalignments, X-ray images acquired from within the device are compared to a CT to compute respective alignment corrections. Unfortunately, deviations of the underlying geometry model for the imaging system degrade the achievable accuracy. We propose an automatic calibration routine, which bases on the geometry of a phantom and its automatic detection in digital radiographs acquired for various geometric device settings during the calibration. The results from the registration of the phantom's X-ray projections and its known geometry are used to update the model of the respective beamlines, which is used to compute the patient alignment correction. The geometric calibration of a beamline takes all nine relevant degrees of freedom into account, including detector translations in three directions, detector tilt by three axes and three possible translations for the X-ray tube. Introducing a stochastic model for the calibration we are able to predict the patient alignment deviations resulting from inaccuracies inherent to the phantom design and the calibration. Comparisons of the alignment results for a treatment device without calibrated imaging systems and a calibrated device show that an accurate calibration can enhance alignment accuracy.

  16. Self-actuating grapple automatically engages and releases loads from overhead cranes

    NASA Technical Reports Server (NTRS)

    Froehlich, J. A.; Karastas, G. A.

    1966-01-01

    Two-piece grapple mechanism consisting of a lift knob secured to the load and a grapple member connected to the crane or lift automatically disengages the load from the overhead lifting device when the load contacts the ground. The key feature is the sliding collar under the lift knob which enables the grapple latch to be stripped off over the lift knob.

  17. Simultaneous validation of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society and the Association for the Advancement of Medical Instrumentation/the International Organization for Standardization protocols.

    PubMed

    Huang, Jinhua; Wang, Yun; Liu, Zhaoying; Wang, Yuling

    2017-02-01

    The aim of this study was to determine the accuracy of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI)/the International Organization for Standardization (ISO) protocols. A total of 85 participants were included for evaluation based on the requirements of the BHS and the AAMI/ISO protocols. The validation procedure and data analysis followed the protocols precisely. The device achieved A/A grading for the BHS protocol and maintained A/A grading throughout the low, medium and high blood pressure ranges. The device also fulfilled the requirement of the AAMI/ISO protocol with device-observer differences of -0.9±5.6 and 0.8±5.2 mmHg for systolic and diastolic blood pressure, respectively, for criterion 1, and -0.9±4.7 and 0.8±4.2 mmHg, respectively, for criterion 2. The Grandway MD2301 digital automatic blood pressure monitor achieved A/A grade of the BHS protocol and passed the requirements of the AAMI/ISO protocol in adults.

  18. 3D image processing architecture for camera phones

    NASA Astrophysics Data System (ADS)

    Atanassov, Kalin; Ramachandra, Vikas; Goma, Sergio R.; Aleksic, Milivoje

    2011-03-01

    Putting high quality and easy-to-use 3D technology into the hands of regular consumers has become a recent challenge as interest in 3D technology has grown. Making 3D technology appealing to the average user requires that it be made fully automatic and foolproof. Designing a fully automatic 3D capture and display system requires: 1) identifying critical 3D technology issues like camera positioning, disparity control rationale, and screen geometry dependency, 2) designing methodology to automatically control them. Implementing 3D capture functionality on phone cameras necessitates designing algorithms to fit within the processing capabilities of the device. Various constraints like sensor position tolerances, sensor 3A tolerances, post-processing, 3D video resolution and frame rate should be carefully considered for their influence on 3D experience. Issues with migrating functions such as zoom and pan from the 2D usage model (both during capture and display) to 3D needs to be resolved to insure the highest level of user experience. It is also very important that the 3D usage scenario (including interactions between the user and the capture/display device) is carefully considered. Finally, both the processing power of the device and the practicality of the scheme needs to be taken into account while designing the calibration and processing methodology.

  19. Comparison of Efficacy and Tolerance of Automatic Continuous Positive Airway Pressure Devices With the Optimum Continuous Positive Airway Pressure.

    PubMed

    Tommi, George; Aronow, Wilbert S; Sheehan, John C; McCleay, Matthew T; Meyers, Patrick G

    Patients diagnosed with obstructive sleep apnea syndrome were randomly placed on automatic continuous positive airway pressure (ACPAP) for 2 hours followed by manual titration for the rest of the night. One hundred sixty-one patients entered the study, with at least 50 patients titrated with each of 3 ACPAP devices. The optimum continuous positive airway pressure (CPAP) was defined as the lowest pressure with an apnea-hypoxia index of ≤5/hr, which ranged from 4 cm to 18 cm. Success with ACPAP was approximately 60%-80% when the optimum CPAP was 4-6 cm but fell to below 30% if the optimum CPAP was ≥8 cm (P = 0.001). Average ACPAP ranged from 2 to 10 cm below the optimum level if the optimum CPAP was ≥8 cm. Patients who responded to a low CPAP but deteriorated on higher pressures failed to respond to any of the automatic devices. We recommend that CPAP titration be performed manually before initiation of ACPAP in patients with obstructive sleep apnea. The basal pressure for ACPAP should be the optimum pressure obtained by manual titration. Limits on the upper level of ACPAP may be necessary for patients who deteriorate on higher positive pressures.

  20. 16 CFR 1501.1 - Purpose.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... IDENTIFYING TOYS AND OTHER ARTICLES INTENDED FOR USE BY CHILDREN UNDER 3 YEARS OF AGE WHICH PRESENT CHOKING... chapter classifies as a banned hazardous substance any toy or other article intended for use by children...

  1. Cold Medicines for Kids: What's the Risk?

    MedlinePlus

    ... thin secretions. Warm liquids, such as tea or chicken soup, might have a soothing effect, increase the ... harmful effects. However, hard candy is a choking hazard and shouldn't be given to younger children. ...

  2. Choking (Heimlich Maneuver)

    MedlinePlus

    ... a hero. Learn CPR Use “ICE” in Your Cell Phone Prepare for Disasters Communication With Your Family And ... the call and send emergency personnel to you. (Cell phone calls may not be traceable to an exact ...

  3. Choking Prevention and Rescue Tips

    MedlinePlus

    ... Workplace Training Driver Training First Aid Training Consulting Surveys Research Safety Topics Fatigue Drugs at Work Driving Workplace ... of an Effective Safety Management System Employee Perception Surveys Research Safety Topics Fatigue Drugs at Work Driving Workplace ...

  4. Household Safety: Preventing Choking

    MedlinePlus

    ... More for Teens Teens site Sitio para adolescentes Body Mind Sexual Health Food & Fitness Diseases & Conditions Infections Drugs & ... exploring are the activities that develop your child's body and mind. Reviewed by: Rupal Christine Gupta, MD Date reviewed: ...

  5. Choking first aid - adult or child over 1 year - slideshow

    MedlinePlus

    ... Duplication for commercial use must be authorized in writing by ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow us Disclaimers Copyright ...

  6. The choking game: A deadly game. Analysis of two cases of "self-strangulation" in young boys and review of the literature.

    PubMed

    Re, Laura; Birkhoff, Jutta M; Sozzi, Marta; Andrello, Luisa; Osculati, Antonio M M

    2015-02-01

    The choking game is defined as a self-strangulation or strangulation by another person with the hands or a noose to achieve a brief euphoric state caused by cerebral hypoxia. Death may occur, but forensic pathologists often classify them as suicides or accidental deaths, without focusing on the possibility that they may result from a deliberate self-temporary-asphyxiation, turned into a deadly game. Presenting two fatal cases of self-strangulation involving an 11-year-old boy and a teenager of 15 years, the authors identify victims' characteristics and death scene's evidence, which may help to distinguish if a death is from an asphyxial suicide or an asphyxial game. Copyright © 2014 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  7. Nonlinear theory of shocked sound propagation in a nearly choked duct flow

    NASA Technical Reports Server (NTRS)

    Myers, M. K.; Callegari, A. J.

    1982-01-01

    The development of shocks in the sound field propagating through a nearly choked duct flow is analyzed by extending a quasi-one dimensional theory. The theory is applied to the case in which sound is introduced into the flow by an acoustic source located in the vicinity of a near-sonic throat. Analytical solutions for the field are obtained which illustrate the essential features of the nonlinear interaction between sound and flow. Numerical results are presented covering ranges of variation of source strength, throat Mach number, and frequency. It is found that the development of shocks leads to appreciable attenuation of acoustic power transmitted upstream through the near-sonic flow. It is possible, for example, that the power loss in the fundamental harmonic can be as much as 90% of that introduced at the source.

  8. Subclinical dysphagia in persons with Prader-Willi syndrome.

    PubMed

    Gross, Roxann Diez; Gisser, Ronit; Cherpes, Gregory; Hartman, Katie; Maheshwary, Rishi

    2017-02-01

    Prader-Willi Syndrome (PWS) is caused by a genetic imprinting abnormality resulting from the lack of expression of the paternal genes at 15q11-q13. Intellectual disability, low muscle tone, and life-threatening hyperphagia are hallmarks of the phenotype. The need for the Heimlich maneuver, death from choking, and pulmonary infection occur in a disproportionally high number of persons with PWS. The widely held belief is that eating behaviors are responsible for choking and aspiration; yet, no investigation had sought to determine if swallowing impairments were present in persons with PWS. To address this research and clinical gap, simultaneous videofluoroscopy and nasal respiratory signals were used to record swallowing function and breathing/swallowing coordination in 30 participants with PWS. Subjects consumed thin liquid and barium cookies under two randomized conditions as follows: (i) controlled (cues to swallow and standardized bolus sizes); (ii) spontaneous (no cues or bolus size control). Under videofluoroscopy, the cohort showed disordered pharyngeal and esophageal swallowing in both conditions with disturbances in timing, clearance, and coordination of swallowing with the respiratory cycle. No participant showed a sensory response such as attempting to clear residue or coughing; thereby supporting the lack of overt symptoms. We conclude that the high death rate from choking and pulmonary infection in children and adults with PWS may be related, in part, to underlying, asymptomatic dysphagia. The combination of rapid eating and dysphagia would increase the risk of aspiration-related morbidity and mortality. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  9. The MOnitoring Resynchronization dEvices and CARdiac patiEnts (MORE-CARE) randomized controlled trial: phase 1 results on dynamics of early intervention with remote monitoring.

    PubMed

    Boriani, Giuseppe; Da Costa, Antoine; Ricci, Renato Pietro; Quesada, Aurelio; Favale, Stefano; Iacopino, Saverio; Romeo, Francesco; Risi, Arnaldo; Mangoni di S Stefano, Lorenza; Navarro, Xavier; Biffi, Mauro; Santini, Massimo; Burri, Haran

    2013-08-21

    Remote monitoring (RM) in patients with advanced heart failure and cardiac resynchronization therapy defibrillators (CRT-D) may reduce delays in clinical decisions by transmitting automatic alerts. However, this strategy has never been tested specifically in this patient population, with alerts for lung fluid overload, and in a European setting. The main objective of Phase 1 (presented here) is to evaluate if RM strategy is able to reduce time from device-detected events to clinical decisions. In this multicenter randomized controlled trial, patients with moderate to severe heart failure implanted with CRT-D devices were randomized to a Remote group (with remote follow-up and wireless automatic alerts) or to a Control group (with standard follow-up without alerts). The primary endpoint of Phase 1 was the delay between an alert event and clinical decisions related to the event in the first 154 enrolled patients followed for 1 year. The median delay from device-detected events to clinical decisions was considerably shorter in the Remote group compared to the Control group: 2 (25(th)-75(th) percentile, 1-4) days vs 29 (25(th)-75(th) percentile, 3-51) days respectively, P=.004. In-hospital visits were reduced in the Remote group (2.0 visits/patient/year vs 3.2 visits/patient/year in the Control group, 37.5% relative reduction, P<.001). Automatic alerts were successfully transmitted in 93% of events occurring outside the hospital in the Remote group. The annual rate of all-cause hospitalizations per patient did not differ between the two groups (P=.65). RM in CRT-D patients with advanced heart failure allows physicians to promptly react to clinically relevant automatic alerts and significantly reduces the burden of in-hospital visits. Clinicaltrials.gov NCT00885677; http://clinicaltrials.gov/show/NCT00885677 (Archived by WebCite at http://www.webcitation.org/6IkcCJ7NF).

  10. The MOnitoring Resynchronization dEvices and CARdiac patiEnts (MORE-CARE) Randomized Controlled Trial: Phase 1 Results on Dynamics of Early Intervention With Remote Monitoring

    PubMed Central

    Da Costa, Antoine; Ricci, Renato Pietro; Quesada, Aurelio; Favale, Stefano; Iacopino, Saverio; Romeo, Francesco; Risi, Arnaldo; Mangoni di S Stefano, Lorenza; Navarro, Xavier; Biffi, Mauro; Santini, Massimo; Burri, Haran

    2013-01-01

    Background Remote monitoring (RM) in patients with advanced heart failure and cardiac resynchronization therapy defibrillators (CRT-D) may reduce delays in clinical decisions by transmitting automatic alerts. However, this strategy has never been tested specifically in this patient population, with alerts for lung fluid overload, and in a European setting. Objective The main objective of Phase 1 (presented here) is to evaluate if RM strategy is able to reduce time from device-detected events to clinical decisions. Methods In this multicenter randomized controlled trial, patients with moderate to severe heart failure implanted with CRT-D devices were randomized to a Remote group (with remote follow-up and wireless automatic alerts) or to a Control group (with standard follow-up without alerts). The primary endpoint of Phase 1 was the delay between an alert event and clinical decisions related to the event in the first 154 enrolled patients followed for 1 year. Results The median delay from device-detected events to clinical decisions was considerably shorter in the Remote group compared to the Control group: 2 (25th-75th percentile, 1-4) days vs 29 (25th-75th percentile, 3-51) days respectively, P=.004. In-hospital visits were reduced in the Remote group (2.0 visits/patient/year vs 3.2 visits/patient/year in the Control group, 37.5% relative reduction, P<.001). Automatic alerts were successfully transmitted in 93% of events occurring outside the hospital in the Remote group. The annual rate of all-cause hospitalizations per patient did not differ between the two groups (P=.65). Conclusions RM in CRT-D patients with advanced heart failure allows physicians to promptly react to clinically relevant automatic alerts and significantly reduces the burden of in-hospital visits. Trial Registration Clinicaltrials.gov NCT00885677; http://clinicaltrials.gov/show/NCT00885677 (Archived by WebCite at http://www.webcitation.org/6IkcCJ7NF). PMID:23965236

  11. A NEW APPROACH TO CLASS SCHEDULING. FINAL REPORT.

    ERIC Educational Resources Information Center

    CANTER, JOHN; AND OTHERS

    AN INVESTIGATION OF THE USE OF A PROTOTYPE DEVICE FOR CLASS SCHEDULING WAS MADE. THE BEEKLEY INSITE DEVICE THAT WAS STUDIED USES THE "PEEK-A-BOO" PRINCIPLE OF MATCHING COMPUTER TAPES. A TEST GROUP OF 149 GRADUATE STUDENTS WAS USED. THEIR DESIRED SCHEDULES WERE MATCHED AUTOMATICALLY AGAINST A PROPOSED MASTER SCHEDULE TO EVALUATE THE…

  12. An adaptive Hidden Markov Model for activity recognition based on a wearable multi-sensor device

    USDA-ARS?s Scientific Manuscript database

    Human activity recognition is important in the study of personal health, wellness and lifestyle. In order to acquire human activity information from the personal space, many wearable multi-sensor devices have been developed. In this paper, a novel technique for automatic activity recognition based o...

  13. Automatic grinding apparatus to control uniform specimen thicknesses

    DOEpatents

    Bryner, Joseph S.

    1982-01-01

    This invention is directed to a new and improved grinding apparatus comprising (1) a movable grinding surface, (2) a specimen holder, (3) a displacing device for moving the holder and/or grinding surface toward one another, and (4) at least three devices for limiting displacement of the holder to the grinding surface.

  14. 14 CFR 23.812 - Emergency lighting.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... light that illuminates in the cockpit when power is on in the airplane and the emergency lighting... station and be provided with automatic activation. The cockpit control device must have “on,” “off,” and... “armed” or “on” positions. (e) The cockpit control device must have provisions to allow the emergency...

  15. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  16. 40 CFR 91.412 - Data logging.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Data logging. 91.412 Section 91.412... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the...

  17. 40 CFR 91.412 - Data logging.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Data logging. 91.412 Section 91.412... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the...

  18. 40 CFR 89.409 - Data logging.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Data logging. 89.409 Section 89.409... Data logging. (a) A computer or any other automatic data processing device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection records the...

  19. 40 CFR 89.409 - Data logging.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Data logging. 89.409 Section 89.409... Data logging. (a) A computer or any other automatic data processing device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection records the...

  20. 40 CFR 91.412 - Data logging.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Data logging. 91.412 Section 91.412... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the...

  1. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  2. 40 CFR 89.409 - Data logging.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Data logging. 89.409 Section 89.409... Data logging. (a) A computer or any other automatic data processing device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection records the...

  3. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  4. 40 CFR 91.412 - Data logging.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Data logging. 91.412 Section 91.412... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the...

  5. 40 CFR 89.409 - Data logging.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Data logging. 89.409 Section 89.409... Data logging. (a) A computer or any other automatic data processing device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection records the...

  6. 40 CFR 91.412 - Data logging.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Data logging. 91.412 Section 91.412... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the...

  7. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  8. 40 CFR 89.409 - Data logging.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Data logging. 89.409 Section 89.409... Data logging. (a) A computer or any other automatic data processing device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection records the...

  9. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  10. A novel automatic regulatory device for continuous bladder irrigation based on wireless sensor in patients after transurethral resection of the prostate: A prospective investigation.

    PubMed

    Ding, Aimin; Cao, Huling; Wang, Lihua; Chen, Jiangang; Wang, Jian; He, Bosheng

    2016-12-01

    Benign prostatic hyperplasia is a common progressive disease in aging men, which leads to a significant impact on daily lives of patients. Continuous bladder irrigation (CBI) is a supplementary option for preventing the adverse events following transurethral resection of the prostate (TURP). Regulation of the flow rate based on the color of drainage bag is significant to prevent the clot formation and retention, which is controlled manually at present. To achieve a better control of flow rate and reduce inappropriate flow rate-related adverse effects, we designed an automatic flow rate controller for CBI applied with wireless sensor and evaluated its clinical efficacy. The therapeutic efficacy was evaluated in patients receiving the novel automatic bladder irrigation post-TURP in the experimental group compared with controls receiving traditional bladder irrigation in the control group. A total of 146 patients were randomly divided into 2 groups-the experimental group (n = 76) and the control group (n = 70). The mean irrigation volume of the experimental group (24.2 ± 3.8 L) was significantly lower than that of the controls (54.6 ± 5.4 L) (P < 0.05). Patients treated with automatic irrigation device had significantly decreased incidence of clot retention (8/76) and cystospasm (12/76) compared to controls (21/70; 39/70, P < 0.05). There was no significant difference between the 2 groups with regard to irrigation time (28.6 ± 2.7 vs 29.5 ± 3.4 hours, P = 0.077). The study suggests that the automatic regulating device applied with wireless sensor for CBI is safe and effective for patients after TURP. However, studies with a large population of patients and a long-term follow-up should be conducted to validate our findings.

  11. A novel automatic regulatory device for continuous bladder irrigation based on wireless sensor in patients after transurethral resection of the prostate

    PubMed Central

    Ding, Aimin; Cao, Huling; Wang, Lihua; Chen, Jiangang; Wang, Jian; He, Bosheng

    2016-01-01

    Abstract Background: Benign prostatic hyperplasia is a common progressive disease in aging men, which leads to a significant impact on daily lives of patients. Continuous bladder irrigation (CBI) is a supplementary option for preventing the adverse events following transurethral resection of the prostate (TURP). Regulation of the flow rate based on the color of drainage bag is significant to prevent the clot formation and retention, which is controlled manually at present. To achieve a better control of flow rate and reduce inappropriate flow rate–related adverse effects, we designed an automatic flow rate controller for CBI applied with wireless sensor and evaluated its clinical efficacy. Methods: The therapeutic efficacy was evaluated in patients receiving the novel automatic bladder irrigation post-TURP in the experimental group compared with controls receiving traditional bladder irrigation in the control group. Results: A total of 146 patients were randomly divided into 2 groups—the experimental group (n = 76) and the control group (n = 70). The mean irrigation volume of the experimental group (24.2 ± 3.8 L) was significantly lower than that of the controls (54.6 ± 5.4 L) (P < 0.05). Patients treated with automatic irrigation device had significantly decreased incidence of clot retention (8/76) and cystospasm (12/76) compared to controls (21/70; 39/70, P < 0.05). There was no significant difference between the 2 groups with regard to irrigation time (28.6 ± 2.7 vs 29.5 ± 3.4 hours, P = 0.077). Conclusion: The study suggests that the automatic regulating device applied with wireless sensor for CBI is safe and effective for patients after TURP. However, studies with a large population of patients and a long-term follow-up should be conducted to validate our findings. PMID:28033276

  12. A device for automatically measuring and supervising the critical care patient's urine output.

    PubMed

    Otero, Abraham; Palacios, Francisco; Akinfiev, Teodor; Fernández, Roemi

    2010-01-01

    Critical care units are equipped with commercial monitoring devices capable of sensing patients' physiological parameters and supervising the achievement of the established therapeutic goals. This avoids human errors in this task and considerably decreases the workload of the healthcare staff. However, at present there still is a very relevant physiological parameter that is measured and supervised manually by the critical care units' healthcare staff: urine output. This paper presents a patent-pending device capable of automatically recording and supervising the urine output of a critical care patient. A high precision scale is used to measure the weight of a commercial urine meter. On the scale's pan there is a support frame made up of Bosch profiles that isolates the scale from force transmission from the patient's bed, and guarantees that the urine flows properly through the urine meter input tube. The scale's readings are sent to a PC via Bluetooth where an application supervises the achievement of the therapeutic goals. The device is currently undergoing tests at a research unit associated with the University Hospital of Getafe in Spain.

  13. Perovskite Photovoltachromic Supercapacitor with All-Transparent Electrodes.

    PubMed

    Zhou, Feichi; Ren, Zhiwei; Zhao, Yuda; Shen, Xinpeng; Wang, Aiwu; Li, Yang Yang; Surya, Charles; Chai, Yang

    2016-06-28

    Photovoltachromic cells (PVCCs) are of great interest for the self-powered smart windows of architectures and vehicles, which require widely tunable transmittance and automatic color change under photostimuli. Organolead halide perovskite possesses high light absorption coefficient and enables thin and semitransparent photovoltaic device. In this work, we demonstrate co-anode and co-cathode photovoltachromic supercapacitors (PVCSs) by vertically integrating a perovskite solar cell (PSC) with MoO3/Au/MoO3 transparent electrode and electrochromic supercapacitor. The PVCSs provide a seamless integration of energy harvesting/storage device, automatic and wide color tunability, and enhanced photostability of PSCs. Compared with conventional PVCC, the counter electrodes of our PVCSs provide sufficient balancing charge, eliminate the necessity of reverse bias voltage for bleaching the device, and realize reasonable in situ energy storage. The color states of PVCSs not only indicate the amount of energy stored and energy consumed in real time, but also enhance the photostability of photovoltaic component by preventing its long-time photoexposure under fully charged state of PVCSs. This work designs PVCS devices for multifunctional smart window applications commonly made of glass.

  14. Choking - adult or child over 1 year

    MedlinePlus

    ... Hockberger RS, Walls RM, eds. Rosen's Emergency Medicine: Concepts and Clinical Practice . 8th ed. Philadelphia, PA: Elsevier ... Hockberger RS, Walls RM, eds. Rosen's Emergency Medicine: Concepts and Clinical Practice . 8th ed. Philadelphia, PA: Elsevier ...

  15. 16 CFR 1117.5 - Information that must be reported and to whom.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... SAFETY ACT REGULATIONS REPORTING OF CHOKING INCIDENTS INVOLVING MARBLES, SMALL BALLS, LATEX BALLOONS AND... (including any labeling and warnings), a description of the marble, small ball, latex balloon or other small...

  16. End Operation Choke Point Act of 2014

    THOMAS, 113th Congress

    Rep. Luetkemeyer, Blaine [R-MO-3

    2014-06-26

    House - 07/15/2014 Hearings Held by the Subcommittee on Financial Institutions and Consumer Credit Prior to Referral. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  17. Framework for automatic information extraction from research papers on nanocrystal devices

    PubMed Central

    Yoshioka, Masaharu; Hara, Shinjiro; Newton, Marcus C

    2015-01-01

    Summary To support nanocrystal device development, we have been working on a computational framework to utilize information in research papers on nanocrystal devices. We developed an annotated corpus called “ NaDev” (Nanocrystal Device Development) for this purpose. We also proposed an automatic information extraction system called “NaDevEx” (Nanocrystal Device Automatic Information Extraction Framework). NaDevEx aims at extracting information from research papers on nanocrystal devices using the NaDev corpus and machine-learning techniques. However, the characteristics of NaDevEx were not examined in detail. In this paper, we conduct system evaluation experiments for NaDevEx using the NaDev corpus. We discuss three main issues: system performance, compared with human annotators; the effect of paper type (synthesis or characterization) on system performance; and the effects of domain knowledge features (e.g., a chemical named entity recognition system and list of names of physical quantities) on system performance. We found that overall system performance was 89% in precision and 69% in recall. If we consider identification of terms that intersect with correct terms for the same information category as the correct identification, i.e., loose agreement (in many cases, we can find that appropriate head nouns such as temperature or pressure loosely match between two terms), the overall performance is 95% in precision and 74% in recall. The system performance is almost comparable with results of human annotators for information categories with rich domain knowledge information (source material). However, for other information categories, given the relatively large number of terms that exist only in one paper, recall of individual information categories is not high (39–73%); however, precision is better (75–97%). The average performance for synthesis papers is better than that for characterization papers because of the lack of training examples for characterization papers. Based on these results, we discuss future research plans for improving the performance of the system. PMID:26665057

  18. Framework for automatic information extraction from research papers on nanocrystal devices.

    PubMed

    Dieb, Thaer M; Yoshioka, Masaharu; Hara, Shinjiro; Newton, Marcus C

    2015-01-01

    To support nanocrystal device development, we have been working on a computational framework to utilize information in research papers on nanocrystal devices. We developed an annotated corpus called " NaDev" (Nanocrystal Device Development) for this purpose. We also proposed an automatic information extraction system called "NaDevEx" (Nanocrystal Device Automatic Information Extraction Framework). NaDevEx aims at extracting information from research papers on nanocrystal devices using the NaDev corpus and machine-learning techniques. However, the characteristics of NaDevEx were not examined in detail. In this paper, we conduct system evaluation experiments for NaDevEx using the NaDev corpus. We discuss three main issues: system performance, compared with human annotators; the effect of paper type (synthesis or characterization) on system performance; and the effects of domain knowledge features (e.g., a chemical named entity recognition system and list of names of physical quantities) on system performance. We found that overall system performance was 89% in precision and 69% in recall. If we consider identification of terms that intersect with correct terms for the same information category as the correct identification, i.e., loose agreement (in many cases, we can find that appropriate head nouns such as temperature or pressure loosely match between two terms), the overall performance is 95% in precision and 74% in recall. The system performance is almost comparable with results of human annotators for information categories with rich domain knowledge information (source material). However, for other information categories, given the relatively large number of terms that exist only in one paper, recall of individual information categories is not high (39-73%); however, precision is better (75-97%). The average performance for synthesis papers is better than that for characterization papers because of the lack of training examples for characterization papers. Based on these results, we discuss future research plans for improving the performance of the system.

  19. Device Rotates Bearing Balls For Inspection

    NASA Technical Reports Server (NTRS)

    Burley, R. K.

    1988-01-01

    Entire surface of ball inspected automatically and quickly. Device holds and rotates bearing ball for inspection by optical or mechanical surface-quality probe, eddy-current probe for detection of surface or subsurface defects, or circumference-measuring tool. Ensures entire surface of ball moves past inspection head quickly. New device saves time and increases reliability of inspections of spherical surfaces. Simple to operate and provides quick and easy access for loading and unloading of balls during inspection.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmes, J.P.; Maxwell, R.L.; Wright, L.J.

    A biometric identification device is an automatic device that can verify a person's identity from a measurement of a physical feature or repeatable action of the individual. A reference measurement of the biometric is obtained when the individual is enrolled on the device. Subsequent verifications are made by comparing the submitted biometric feature against the reference sample. Sandia Laboratories has been evaluating the relative performance of several identity verifiers, using volunteer test subjects. Sandia testing methods and results are discussed.

  1. Methodology Investigation Automatic Magnetic Recording Borescope.

    DTIC Science & Technology

    1986-01-01

    or other brushless signal coupling devices to the extent possible and feasible to reduce or eliminate the need for slip ring and brush type signal...the inspection head, is used to magnetically couple the necessary energy across the rotary interface. Because there is (1) an appreciable air gap in...were written. (2) As required by the contract, the signal conditioners in the MB employ automatic gain control to compensate for the changes in

  2. Director, Operational Test and Evaluation FY 2004 Annual Report

    DTIC Science & Technology

    2004-01-01

    HIGH) Space Based Radar (SBR) Sensor Fuzed Weapon (SFW) P3I (CBU-97/B) Small Diameter Bomb (SDB) Secure Mobile Anti-Jam Reliable Tactical Terminal...detection, identification, and sampling capability for both fixed-site and mobile operations. The system must automatically detect and identify up to ten...staffing within the Services. SYSTEM DESCRIPTION AND MISSION The Services envision JCAD as a hand-held device that automatically detects, identifies, and

  3. A Low-Cost Device for Automatic Photometric Titrations

    NASA Astrophysics Data System (ADS)

    Rocha, Fábio R. P.; Reis, Boaventura F.

    2000-02-01

    Electronics is an important topic in chemistry courses. However, the introduction of basic concepts is often difficult and the lab instruments are frequently seen as "black boxes". To address this problem, we propose the construction of a simple, low-cost (about $150 U.S.) automatic photometric titrator employing a light-emitting diode (LED) and a phototransistor. The electronic circuit can be assembled by the students themselves. The device was employed to implement a common procedure in chemical labs, making feasible the introduction of concepts related to electronics in undergraduate chemistry courses. The titrator is able to work automatically, since a feedback system permits stopping the addition of titrant solution when the end-point is achieved. With this demonstration, it can be stressed that automatic procedures can be implemented without expensive instruments. Additionally, a classical procedure becomes more attractive to the students and its importance to chemical analysis can be emphasized. The feasibility of the titrator was demonstrated by acid-base titrations of HCl solutions with NaOH in the presence of phenolphthalein and by iodimetric determination of ascorbic acid in vitamin C tablets and lemon juice. Precise results (0.7% relative standard deviation, n = 10) in agreement at the 95% confidence level with those attained by a conventional procedure were obtained.

  4. Frequency Domain Modeling of SAW Devices

    NASA Technical Reports Server (NTRS)

    Wilson, W. C.; Atkinson, G. M.

    2007-01-01

    New SAW sensors for integrated vehicle health monitoring of aerospace vehicles are being investigated. SAW technology is low cost, rugged, lightweight, and extremely low power. However, the lack of design tools for MEMS devices in general, and for Surface Acoustic Wave (SAW) devices specifically, has led to the development of tools that will enable integrated design, modeling, simulation, analysis and automatic layout generation of SAW devices. A frequency domain model has been created. The model is mainly first order, but it includes second order effects from triple transit echoes. This paper presents the model and results from the model for a SAW delay line device.

  5. Multi-stream face recognition on dedicated mobile devices for crime-fighting

    NASA Astrophysics Data System (ADS)

    Jassim, Sabah A.; Sellahewa, Harin

    2006-09-01

    Automatic face recognition is a useful tool in the fight against crime and terrorism. Technological advance in mobile communication systems and multi-application mobile devices enable the creation of hybrid platforms for active and passive surveillance. A dedicated mobile device that incorporates audio-visual sensors would not only complement existing networks of fixed surveillance devices (e.g. CCTV) but could also provide wide geographical coverage in almost any situation and anywhere. Such a device can hold a small portion of a law-enforcing agency biometric database that consist of audio and/or visual data of a number of suspects/wanted or missing persons who are expected to be in a local geographical area. This will assist law-enforcing officers on the ground in identifying persons whose biometric templates are downloaded onto their devices. Biometric data on the device can be regularly updated which will reduce the number of faces an officer has to remember. Such a dedicated device would act as an active/passive mobile surveillance unit that incorporate automatic identification. This paper is concerned with the feasibility of using wavelet-based face recognition schemes on such devices. The proposed schemes extend our recently developed face verification scheme for implementation on a currently available PDA. In particular we will investigate the use of a combination of wavelet frequency channels for multi-stream face recognition. We shall present experimental results on the performance of our proposed schemes for a number of publicly available face databases including a new AV database of videos recorded on a PDA.

  6. 16 CFR 1117.4 - Time for filing a report.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... REPORTING OF CHOKING INCIDENTS INVOLVING MARBLES, SMALL BALLS, LATEX BALLOONS AND OTHER SMALL PARTS § 1117.4... marble, small ball, or latex balloon or on a marble, small ball, latex balloon, or other small part...

  7. Determining queue and congestion in highway work zone bottlenecks.

    DOT National Transportation Integrated Search

    2011-03-11

    Construction zones, though required for infrastructure maintenance, have become congestion choke points on most highway systems in the US. The congestion may create potentially unsafe driving conditions for approaching motorists that do not expect qu...

  8. Determining Queue and Congestion in Highway Work Zone Bottlenecks

    DOT National Transportation Integrated Search

    2011-03-11

    Construction zones, though required for infrastructure maintenance, have become congestion choke points on most highway systems in the US. The congestion may create potentially unsafe driving conditions for approaching motorists that do not expect qu...

  9. Swimming

    MedlinePlus

    ... or eat while you swim — you could choke. Lakes and Ponds Lots of kids swim in streams, lakes, or ponds. Take extra care when swimming in ... can't always see the bottom of the lake or pond, so you don't always know ...

  10. Electromagnetic interference filter for automotive electrical systems

    DOEpatents

    Herron, Nicholas Hayden; Carlson, Douglas S; Tang, David; Korich, Mark D

    2013-07-02

    A filter for an automotive electrical system includes a substrate having first and second conductive members. First and second input terminals are mounted to the substrate. The first input terminal is electrically connected to the first conductive member, and the second input terminal is electrically connected to the second conductive member. A plurality of capacitors are mounted to the substrate. Each of the capacitors is electrically connected to at least one of the first and second conductive members. First and second power connectors are mounted to the substrate. The first power connector is electrically connected to the first conductive member, and the second power connector is electrically connected to the second conductive member. A common mode choke is coupled to the substrate and arranged such that the common mode choke extends around at least a portion of the substrate and the first and second conductive members.

  11. Unsteady Full Annulus Simulations of a Transonic Axial Compressor Stage

    NASA Technical Reports Server (NTRS)

    Herrick, Gregory P.; Hathaway, Michael D.; Chen, Jen-Ping

    2009-01-01

    Two recent research endeavors in turbomachinery at NASA Glenn Research Center have focused on compression system stall inception and compression system aerothermodynamic performance. Physical experiment and computational research are ongoing in support of these research objectives. TURBO, an unsteady, three-dimensional, Navier-Stokes computational fluid dynamics code commissioned and developed by NASA, has been utilized, enhanced, and validated in support of these endeavors. In the research which follows, TURBO is shown to accurately capture compression system flow range-from choke to stall inception-and also to accurately calculate fundamental aerothermodynamic performance parameters. Rigorous full-annulus calculations are performed to validate TURBO s ability to simulate the unstable, unsteady, chaotic stall inception process; as part of these efforts, full-annulus calculations are also performed at a condition approaching choke to further document TURBO s capabilities to compute aerothermodynamic performance data and support a NASA code assessment effort.

  12. Team history and choking under pressure in major soccer penalty shootouts.

    PubMed

    Jordet, Geir; Hartman, Esther; Vuijk, Pieter Jelle

    2012-05-01

    This study examined the links between historical team results and individual players' subsequent performances in a high-pressure real-world sport situation. Videos were obtained from all soccer penalty shootouts held in two major international tournaments (World Cup and European Championships) between 1976 and 2006 (n=260 players/309 kicks), and we controlled for team ability and country. The results showed that players on teams with preceding losses performed worse and generally took their shots more quickly than players on teams with preceding wins. These differences were also found with players who took no personal part in the preceding games. In conclusion, the results support the existence of historical dependency effects for performance on important and dramatic high-pressure tasks and they are in part consistent with a view of choking under pressure as a function of threatened egotism and self-regulation failure. ©2011 The British Psychological Society.

  13. The choking game and YouTube: a dangerous combination.

    PubMed

    Linkletter, Martha; Gordon, Kevin; Dooley, Joe

    2010-03-01

    To study postings of partial asphyxiation by adolescents on YouTube and to increase awareness of this dangerous activity as well as the value of YouTube as a research tool. Videos were searched on YouTube using many terms for recreational partial asphyxiation. Data were gathered on the participants and on the occurrence of hypoxic seizure. Sixty-five videos of the asphyxiation game were identified. Most (90%) participants were male. A variety of techniques were used. Hypoxic seizures were witnessed in 55% of videos, but occurred in 88% of videos that employed the "sleeper hold" technique. The videos were collectively viewed 173550 times on YouTube. YouTube has enabled millions of young people to watch videos of the "choking game" and other dangerous activities. Seeing videos may normalize the behavior among adolescents. Increased awareness of this activity may prevent some youths from participating and potentially harming themselves or others.

  14. Choke or thrive? The relation between salivary cortisol and math performance depends on individual differences in working memory and math-anxiety.

    PubMed

    Mattarella-Micke, Andrew; Mateo, Jill; Kozak, Megan N; Foster, Katherine; Beilock, Sian L

    2011-08-01

    In the current study, we explored how a person's physiological arousal relates to their performance in a challenging math situation as a function of individual differences in working memory (WM) capacity and math-anxiety. Participants completed demanding math problems before and after which salivary cortisol, an index of arousal, was measured. The performance of lower WM individuals did not depend on cortisol concentration or math-anxiety. For higher WM individuals high in math-anxiety, the higher their concentration of salivary cortisol following the math task, the worse their performance. In contrast, for higher WM individuals lower in math-anxiety, the higher their salivary cortisol concentrations, the better their performance. For individuals who have the capacity to perform at a high-level (higher WMs), whether physiological arousal will lead an individual to choke or thrive depends on math-anxiety. 2011 APA, all rights reserved

  15. Childhood and adolescent animal cruelty methods and their possible link to adult violent crimes.

    PubMed

    Hensley, Christopher; Tallichet, Suzanne E

    2009-01-01

    Few researchers have investigated the potentially predictive power of childhood and adolescent animal cruelty methods as they are associated with subsequent interpersonal violence in adulthood. Based on a sample of 261 inmates at medium- and maximum-security prisons in a southern state, the present study examines the relationship between several retrospectively reported animal cruelty methods (drowned, hit or kicked, shot, choked, burned, and had sex) and violent criminal acts committed against humans (assault, rape, and murder). More than half of the sample reported they had shot animals, and almost half had either kicked or hit them. About one in five said they had choked animals, and about one in seven said they had either drowned, burned, or had sex with them. Regression analyses revealed that drowning and having sex with an animal was predictive of later interpersonal violence as adults.

  16. Investigation of starting transients in the thermally choked ram accelerator

    NASA Technical Reports Server (NTRS)

    Burnham, E. A.; Hinkey, J. B.; Bruckner, A. P.

    1992-01-01

    An experimental investigation of the starting transients of the thermally choked ram accelerator is presented in this paper. Construction of a highly instrumented tube section and instrumentation inserts provide high resolution experimental pressure, luminosity, and electromagnetic data of the starting transients. Data obtained prior to and following the entrance diaphragm show detailed development of shock systems in both combustible and inert mixtures. With an evacuated launch tube, starting the diffuser is possible at any Mach number above the Kantrowitz Mach number. The detrimental effects and possible solutions of higher launch tube pressures and excessive obturator leakage (blow-by) are discussed. Ignition of a combustible mixture is demonstrated with both perforated and solid obturators. The relative advantages and disadvantages of each are discussed. Data obtained from these starting experiments enhance the understanding of the ram accelerator, as well as assist in the validation of unsteady, chemically reacting CFD codes.

  17. Neurological abnormalities in the `cri-du-chat' syndrome 1

    PubMed Central

    Colover, Jack; Lucas, Mary; Comley, J. A.; Roe, A. M.

    1972-01-01

    An unusual case of the cri-du-chat syndrome is described in a 6½ year old boy, who, as well as attacks of stridor and choking, showed disorders of spatial perception and cerebellar signs in the form of nystagmus, clumsiness of the hands, and ataxia. Pyramidal signs were also present. He was only mildly retarded mentally. Psychological testing showed that he had a severe deficit for number processing, and also constructional apraxia. Surprisingly, his vocabulary was quite good, as was his reading capacity. Chromosome analysis showed a very small deletion of the short arm of the group B chromosome. In infancy this diagnosis may be suspected because of the high-pitched cry and attacks of stridor and choking. In late childhood, when the signs may be only of a neurological disorder, its recognition may be difficult without confirmation from chromosome studies. The neurological features of this disease are reviewed. Images PMID:5084140

  18. Who Chokes Under Pressure? The Big Five Personality Traits and Decision-Making under Pressure.

    PubMed

    Byrne, Kaileigh A; Silasi-Mansat, Crina D; Worthy, Darrell A

    2015-02-01

    The purpose of the present study was to examine whether the Big Five personality factors could predict who thrives or chokes under pressure during decision-making. The effects of the Big Five personality factors on decision-making ability and performance under social (Experiment 1) and combined social and time pressure (Experiment 2) were examined using the Big Five Personality Inventory and a dynamic decision-making task that required participants to learn an optimal strategy. In Experiment 1, a hierarchical multiple regression analysis showed an interaction between neuroticism and pressure condition. Neuroticism negatively predicted performance under social pressure, but did not affect decision-making under low pressure. Additionally, the negative effect of neuroticism under pressure was replicated using a combined social and time pressure manipulation in Experiment 2. These results support distraction theory whereby pressure taxes highly neurotic individuals' cognitive resources, leading to sub-optimal performance. Agreeableness also negatively predicted performance in both experiments.

  19. Theoretical investigation of operation modes of MHD generators for energy-bypass engines

    NASA Astrophysics Data System (ADS)

    Tang, Jingfeng; Li, Nan; Yu, Daren

    2014-12-01

    A MHD generator with different arrangements of electromagnetic fields will lead the generator working in three modes. A quasi-one-dimensional approximation is used for the model of the MHD generator to analyze the inner mechanism of operation modes. For the MHD generator with a uniform constant magnetic field, a specific critical electric field E cr is required to decelerate a supersonic entrance flow into a subsonic exit flow. Otherwise, the generator works in a steady mode with a larger electric field than E cr in which a steady supersonic flow is provided at the exit, or the generator works in a choked mode with a smaller electric field than E cr in which the supersonic entrance flow is choked in the channel. The detailed flow field characteristics in different operation modes are discussed, demonstrating the relationship of operation modes with electromagnetic fields.

  20. Computational Fluid Dynamic Modeling of Rocket Based Combined Cycle Engine Flowfields

    NASA Technical Reports Server (NTRS)

    Daines, Russell L.; Merkle, Charles L.

    1994-01-01

    Computational Fluid Dynamic techniques are used to study the flowfield of a fixed geometry Rocket Based Combined Cycle engine operating in rocket ejector mode. Heat addition resulting from the combustion of injected fuel causes the subsonic engine flow to choke and go supersonic in the slightly divergent combustor-mixer section. Reacting flow computations are undertaken to predict the characteristics of solutions where the heat addition is determined by the flowfield. Here, adaptive gridding is used to improve resolution in the shear layers. Results show that the sonic speed is reached in the unheated portions of the flow first, while the heated portions become supersonic later. Comparison with results from another code show reasonable agreement. The coupled solutions show that the character of the combustion-based thermal choking phenomenon can be controlled reasonably well such that there is opportunity to optimize the length and expansion ratio of the combustor-mixer.

Top