Automatic Control of the Concrete Mixture Homogeneity in Cycling Mixers
NASA Astrophysics Data System (ADS)
Anatoly Fedorovich, Tikhonov; Drozdov, Anatoly
2018-03-01
The article describes the factors affecting the concrete mixture quality related to the moisture content of aggregates, since the effectiveness of the concrete mixture production is largely determined by the availability of quality management tools at all stages of the technological process. It is established that the unaccounted moisture of aggregates adversely affects the concrete mixture homogeneity and, accordingly, the strength of building structures. A new control method and the automatic control system of the concrete mixture homogeneity in the technological process of mixing components have been proposed, since the tasks of providing a concrete mixture are performed by the automatic control system of processing kneading-and-mixing machinery with operational automatic control of homogeneity. Theoretical underpinnings of the control of the mixture homogeneity are presented, which are related to a change in the frequency of vibrodynamic vibrations of the mixer body. The structure of the technical means of the automatic control system for regulating the supply of water is determined depending on the change in the concrete mixture homogeneity during the continuous mixing of components. The following technical means for establishing automatic control have been chosen: vibro-acoustic sensors, remote terminal units, electropneumatic control actuators, etc. To identify the quality indicator of automatic control, the system offers a structure flowchart with transfer functions that determine the ACS operation in transient dynamic mode.
PACS quality control and automatic problem notifier
NASA Astrophysics Data System (ADS)
Honeyman-Buck, Janice C.; Jones, Douglas; Frost, Meryll M.; Staab, Edward V.
1997-05-01
One side effect of installing a clinical PACS Is that users become dependent upon the technology and in some cases it can be very difficult to revert back to a film based system if components fail. The nature of system failures range from slow deterioration of function as seen in the loss of monitor luminance through sudden catastrophic loss of the entire PACS networks. This paper describes the quality control procedures in place at the University of Florida and the automatic notification system that alerts PACS personnel when a failure has happened or is anticipated. The goal is to recover from a failure with a minimum of downtime and no data loss. Routine quality control is practiced on all aspects of PACS, from acquisition, through network routing, through display, and including archiving. Whenever possible, the system components perform self and between platform checks for active processes, file system status, errors in log files, and system uptime. When an error is detected or a exception occurs, an automatic page is sent to a pager with a diagnostic code. Documentation on each code, trouble shooting procedures, and repairs are kept on an intranet server accessible only to people involved in maintaining the PACS. In addition to the automatic paging system for error conditions, acquisition is assured by an automatic fax report sent on a daily basis to all technologists acquiring PACS images to be used as a cross check that all studies are archived prior to being removed from the acquisition systems. Daily quality control is preformed to assure that studies can be moved from each acquisition and contrast adjustment. The results of selected quality control reports will be presented. The intranet documentation server will be described with the automatic pager system. Monitor quality control reports will be described and the cost of quality control will be quantified. As PACS is accepted as a clinical tool, the same standards of quality control must be established as are expected on other equipment used in the diagnostic process.
NASA Astrophysics Data System (ADS)
Pries, V. V.; Proskuriakov, N. E.
2018-04-01
To control the assembly quality of multi-element mass-produced products on automatic rotor lines, control methods with operational feedback are required. However, due to possible failures in the operation of the devices and systems of automatic rotor line, there is always a real probability of getting defective (incomplete) products into the output process stream. Therefore, a continuous sampling control of the products completeness, based on the use of statistical methods, remains an important element in managing the quality of assembly of multi-element mass products on automatic rotor lines. The feature of continuous sampling control of the multi-element products completeness in the assembly process is its breaking sort, which excludes the possibility of returning component parts after sampling control to the process stream and leads to a decrease in the actual productivity of the assembly equipment. Therefore, the use of statistical procedures for continuous sampling control of the multi-element products completeness when assembled on automatic rotor lines requires the use of such sampling plans that ensure a minimum size of control samples. Comparison of the values of the limit of the average output defect level for the continuous sampling plan (CSP) and for the automated continuous sampling plan (ACSP) shows the possibility of providing lower limit values for the average output defects level using the ACSP-1. Also, the average sample size when using the ACSP-1 plan is less than when using the CSP-1 plan. Thus, the application of statistical methods in the assembly quality management of multi-element products on automatic rotor lines, involving the use of proposed plans and methods for continuous selective control, will allow to automating sampling control procedures and the required level of quality of assembled products while minimizing sample size.
NASA Technical Reports Server (NTRS)
1983-01-01
This report summarizes the results of a study conducted by Engineering and Economics Research (EER), Inc. under NASA Contract Number NAS5-27513. The study involved the development of preliminary concepts for automatic and semiautomatic quality assurance (QA) techniques for ground image processing. A distinction is made between quality assessment and the more comprehensive quality assurance which includes decision making and system feedback control in response to quality assessment.
Automatic Control of Silicon Melt Level
NASA Technical Reports Server (NTRS)
Duncan, C. S.; Stickel, W. B.
1982-01-01
A new circuit, when combined with melt-replenishment system and melt level sensor, offers continuous closed-loop automatic control of melt-level during web growth. Installed on silicon-web furnace, circuit controls melt-level to within 0.1 mm for as long as 8 hours. Circuit affords greater area growth rate and higher web quality, automatic melt-level control also allows semiautomatic growth of web over long periods which can greatly reduce costs.
Automatic Rotational Sky Quality Meter (R-SQM) Design and Software for Astronomical Observatories
NASA Astrophysics Data System (ADS)
Dogan, E.; Ozbaldan, E. E.; Shameoni, Niaei M.; Yesilyaprak, C.
2016-12-01
We have presented the new design of Sky Quality Meter (SQM) device that is an automatic rotational model of sky quality meter (R-SQM) carried out by DAG (Eastern Anatolia Observatory) Technical Team. R-SQM is required for determining the long-term changes of sky quality of an astronomical observatory and consists of four SQM devices mounted on a rotating shaft with different angles for scanning all sky. This system is controlled by a Raspberry Pi control card and a step motor with its driver and a special software.
Automatic retinal interest evaluation system (ARIES).
Yin, Fengshou; Wong, Damon Wing Kee; Yow, Ai Ping; Lee, Beng Hai; Quan, Ying; Zhang, Zhuo; Gopalakrishnan, Kavitha; Li, Ruoying; Liu, Jiang
2014-01-01
In recent years, there has been increasing interest in the use of automatic computer-based systems for the detection of eye diseases such as glaucoma, age-related macular degeneration and diabetic retinopathy. However, in practice, retinal image quality is a big concern as automatic systems without consideration of degraded image quality will likely generate unreliable results. In this paper, an automatic retinal image quality assessment system (ARIES) is introduced to assess both image quality of the whole image and focal regions of interest. ARIES achieves 99.54% accuracy in distinguishing fundus images from other types of images through a retinal image identification step in a dataset of 35342 images. The system employs high level image quality measures (HIQM) to perform image quality assessment, and achieves areas under curve (AUCs) of 0.958 and 0.987 for whole image and optic disk region respectively in a testing dataset of 370 images. ARIES acts as a form of automatic quality control which ensures good quality images are used for processing, and can also be used to alert operators of poor quality images at the time of acquisition.
Automatic-Control System for Safer Brazing
NASA Technical Reports Server (NTRS)
Stein, J. A.; Vanasse, M. A.
1986-01-01
Automatic-control system for radio-frequency (RF) induction brazing of metal tubing reduces probability of operator errors, increases safety, and ensures high-quality brazed joints. Unit combines functions of gas control and electric-power control. Minimizes unnecessary flow of argon gas into work area and prevents electrical shocks from RF terminals. Controller will not allow power to flow from RF generator to brazing head unless work has been firmly attached to head and has actuated micro-switch. Potential shock hazard eliminated. Flow of argon for purging and cooling must be turned on and adjusted before brazing power applied. Provision ensures power not applied prematurely, causing damaged work or poor-quality joints. Controller automatically turns off argon flow at conclusion of brazing so potentially suffocating gas does not accumulate in confined areas.
40 CFR 85.2233 - Steady state test equipment calibrations, adjustments, and quality control-EPA 91.
Code of Federal Regulations, 2010 CFR
2010-07-01
... compensated for automatically and statistical process control demonstrates equal or better quality control... calibrations, adjustments, and quality control-EPA 91. 85.2233 Section 85.2233 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM MOBILE...
Gennaro, G; Ballaminut, A; Contento, G
2017-09-01
This study aims to illustrate a multiparametric automatic method for monitoring long-term reproducibility of digital mammography systems, and its application on a large scale. Twenty-five digital mammography systems employed within a regional screening programme were controlled weekly using the same type of phantom, whose images were analysed by an automatic software tool. To assess system reproducibility levels, 15 image quality indices (IQIs) were extracted and compared with the corresponding indices previously determined by a baseline procedure. The coefficients of variation (COVs) of the IQIs were used to assess the overall variability. A total of 2553 phantom images were collected from the 25 digital mammography systems from March 2013 to December 2014. Most of the systems showed excellent image quality reproducibility over the surveillance interval, with mean variability below 5%. Variability of each IQI was 5%, with the exception of one index associated with the smallest phantom objects (0.25 mm), which was below 10%. The method applied for reproducibility tests-multi-detail phantoms, cloud automatic software tool to measure multiple image quality indices and statistical process control-was proven to be effective and applicable on a large scale and to any type of digital mammography system. • Reproducibility of mammography image quality should be monitored by appropriate quality controls. • Use of automatic software tools allows image quality evaluation by multiple indices. • System reproducibility can be assessed comparing current index value with baseline data. • Overall system reproducibility of modern digital mammography systems is excellent. • The method proposed and applied is cost-effective and easily scalable.
The impact of translucent fabric shades and control strategies on energy savings and visual quality
NASA Astrophysics Data System (ADS)
Wankanapon, Pimonmart
Translucent fabric shades provide opportunities for building occupants to control sunlight penetration for heat reduction, thermal comfort, and visual quality. Regulating shades affects building energy and can potentially reduce the size of mechanical cooling systems. Shades are not normally included in energy model studies during the design process, even though shades potential impact energy use. This is because the occupants normally leave shades closed a large fraction of the time, but models are generally performed with no shades. Automatic shade control is now available, so it is necessary to understand the impact of shades on visual quality and their energy saving potential in order to optimize their overall performance. There are very limited studies that have address shades and their integrated performance on energy consumption and visual quality. Most of these do not reflected modern shade types and their application. The goals of this study are: First, to determine the impact of shades on total, heating, cooling and lighting energy savings with different design and operation parameters. Second, to study and develop different automatic shade control strategies to promote and optimize energy savings and visual quality. A simulation-based approach using EnergyPlus in a parametric study provide better understanding energy savings under different shade conditions. The parametric runs addressed various building parameters such as geometry, orientation, site climate, glazing/shade properties, and shade control strategies with integrated lighting control. The impact of shades was determined for total building and space heating, cooling and lighting energy savings. The effect of shades on visual quality was studied using EnergyPlus, AGI32 and DAYSIM for several indices such as daylight glare index (DGI), work plane illuminance, luminance ratios and view. Different shade control strategies and integrated lighting control were considered with two translucent fabric shade colors. The results clearly show the benefit of automatic shade control strategies with integrated lighting control over a condition when shades are closed all day. The main contributor to the total energy savings is from lighting energy savings, followed by cooling energy savings. Shades provide greater benefit in a hot climate and in a moderate climate than in a cold climate. Different control strategies provide savings in the range of 7-35% for annual total space energy with higher savings with light colored shades. Control strategies of shades should be selected and optimized based on climate, orientation, window area, and window/shade properties. High performance glazings, when equipped with shades, show lower energy savings when compared to standard glazings. High transmittance/reflectance shades, such as white shades, perform better than dark shades in most of the cases due to higher lighting energy savings obtained with the automatic electric lighting control and the resulting cooling energy savings from rejection of some solar energy and a reduction in the heat from lights. A South orientation showed the least benefit of automatic control of shades when compare to other orientations due to the large fraction of time shades are required to provide visual comfort. Under automatic shade control, energy savings are higher the more often the shades can be raised. The different automatic control strategies present tradeoffs between energy savings and comfort. With regard to visual quality, daylight quality assessments on view, glare, luminance ratios, and UDI can be used to assess shade control strategies. Automatic shade control can increase the number of view hours while controlling sunlight penetration. With automatic shade control, more daylight hours can be provided within the beneficial range of 100-2000 lux compared to shades that are closed all day. For a person facing the window, discomfort glare is likely to increase the more often the shades are raised. Keeping the shades down ensures an acceptable glare condition, but limits energy savings. Luminance ratios are another metric that can be used to assess shade performance. With white shades, the luminance ratios between the task and proximate surfaces are improved. Dark shades help improve the luminance ratios between the task and distant surfaces. When the shades are left open, even with no direct sunlight in the space, task to window luminance ratios will often exceed 1:10.
NASA Astrophysics Data System (ADS)
Barufaldi, Bruno; Borges, Lucas R.; Bakic, Predrag R.; Vieira, Marcelo A. C.; Schiabel, Homero; Maidment, Andrew D. A.
2017-03-01
Automatic exposure control (AEC) is used in mammography to obtain acceptable radiation dose and adequate image quality regardless of breast thickness and composition. Although there are physics methods for assessing the AEC, it is not clear whether mammography systems operate with optimal dose and image quality in clinical practice. In this work, we propose the use of a normalized anisotropic quality index (NAQI), validated in previous studies, to evaluate the quality of mammograms acquired using AEC. The authors used a clinical dataset that consists of 561 patients and 1,046 mammograms (craniocaudal breast views). The results show that image quality is often maintained, even at various radiation levels (mean NAQI = 0.14 +/- 0.02). However, a more careful analysis of NAQI reveals that the average image quality decreases as breast thickness increases. The NAQI is reduced by 32% on average, when the breast thickness increases from 31 to 71 mm. NAQI also decreases with lower breast density. The variation in breast parenchyma alone cannot fully account for the decrease of NAQI with thickness. Examination of images shows that images of large, fatty breasts are often inadequately processed. This work shows that NAQI can be applied in clinical mammograms to assess mammographic image quality, and highlights the limitations of the automatic exposure control for some images.
Moderators of the Relationship between Implicit and Explicit Evaluation
ERIC Educational Resources Information Center
Nosek, Brian A.
2005-01-01
Automatic and controlled modes of evaluation sometimes provide conflicting reports of the quality of social objects. This article presents evidence for 4 moderators of the relationship between automatic (implicit) and controlled (explicit) evaluations. Implicit and explicit preferences were measured for a variety of object pairs using a large…
NASA Astrophysics Data System (ADS)
Larin, A. B.; Kolegov, A. V.
2012-10-01
Results of industrial tests of the new method used for the automatic chemical control of the quality of boiler water of the drum-type power boiler ( P d = 13.8 MPa) are described. The possibility of using an H-cationite column for measuring the electric conductivity of an H-cationized sample of boiler water over a long period of time is shown.
An Evaluation of Automatic Control System Concepts for General Aviation Airplanes
NASA Technical Reports Server (NTRS)
Stewart, E. C.
1990-01-01
A piloted simulation study of automatic longitudinal control systems for general aviation airplanes has been conducted. These automatic control systems were designed to make the simulated airplane easy to fly for a beginning or infrequent pilot. Different control systems are presented and their characteristics are documented. In a conventional airplane control system each cockpit controller commands combinations of both the airspeed and the vertical speed. The best system in the present study decoupled the airspeed and vertical speed responses to cockpit controller inputs. An important feature of the automatic system was that neither changing flap position nor maneuvering in steeply banked turns affected either the airspeed or the vertical speed. All the pilots who flew the control system simulation were favorably impressed with the very low workload and the excellent handling qualities of the simulated airplane.
Automatic orbital GTAW welding: Highest quality welds for tomorrow's high-performance systems
NASA Technical Reports Server (NTRS)
Henon, B. K.
1985-01-01
Automatic orbital gas tungsten arc welding (GTAW) or TIG welding is certain to play an increasingly prominent role in tomorrow's technology. The welds are of the highest quality and the repeatability of automatic weldings is vastly superior to that of manual welding. Since less heat is applied to the weld during automatic welding than manual welding, there is less change in the metallurgical properties of the parent material. The possibility of accurate control and the cleanliness of the automatic GTAW welding process make it highly suitable to the welding of the more exotic and expensive materials which are now widely used in the aerospace and hydrospace industries. Titanium, stainless steel, Inconel, and Incoloy, as well as, aluminum can all be welded to the highest quality specifications automatically. Automatic orbital GTAW equipment is available for the fusion butt welding of tube-to-tube, as well as, tube to autobuttweld fittings. The same equipment can also be used for the fusion butt welding of up to 6 inch pipe with a wall thickness of up to 0.154 inches.
Silicon Sheet Quality is Improved By Meniscus Control
NASA Technical Reports Server (NTRS)
Yates, D. A.; Hatch, A. E.; Goldsmith, J. M.
1983-01-01
Better quality silicon crystals for solar cells are possible with instrument that monitors position of meniscus as sheet of solid silicon is drawn from melt. Using information on meniscus height, instrument generates feedback signal to control melt temperature. Automatic control ensures more uniform silicon sheets.
Automated single-slide staining device. [in clinical bacteriology
NASA Technical Reports Server (NTRS)
Wilkins, J. R.; Mills, S. M.
1975-01-01
An automatic single-slide Gram staining device is described. A timer-actuated solenoid controls the dispensing of gentian violet, Gram iodine solution, decolorizer, and 1% aqueous safranin in proper sequence and for the time required for optimum staining. The amount of stain or reagent delivered is controlled by means of stopcocks below each solenoid. Used stains and reagents can be flushed automatically or manually. Smears Gram stained automatically are equal in quality to those prepared manually. The time to complete one Gram cycle is 4.80 min.
Lim, Jiyeon; Park, Eun-Ah; Lee, Whal; Shim, Hackjoon; Chung, Jin Wook
2015-06-01
To assess the image quality and radiation exposure of 320-row area detector computed tomography (320-ADCT) coronary angiography with optimal tube voltage selection with the guidance of an automatic exposure control system in comparison with a body mass index (BMI)-adapted protocol. Twenty-two patients (study group) underwent 320-ADCT coronary angiography using an automatic exposure control system with the target standard deviation value of 33 as the image quality index and the lowest possible tube voltage. For comparison, a sex- and BMI-matched group (control group, n = 22) using a BMI-adapted protocol was established. Images of both groups were reconstructed by an iterative reconstruction algorithm. For objective evaluation of the image quality, image noise, vessel density, signal to noise ratio (SNR), and contrast to noise ratio (CNR) were measured. Two blinded readers then subjectively graded the image quality using a four-point scale (1: nondiagnostic to 4: excellent). Radiation exposure was also measured. Although the study group tended to show higher image noise (14.1 ± 3.6 vs. 9.3 ± 2.2 HU, P = 0.111) and higher vessel density (665.5 ± 161 vs. 498 ± 143 HU, P = 0.430) than the control group, the differences were not significant. There was no significant difference between the two groups for SNR (52.5 ± 19.2 vs. 60.6 ± 21.8, P = 0.729), CNR (57.0 ± 19.8 vs. 67.8 ± 23.3, P = 0.531), or subjective image quality scores (3.47 ± 0.55 vs. 3.59 ± 0.56, P = 0.960). However, radiation exposure was significantly reduced by 42 % in the study group (1.9 ± 0.8 vs. 3.6 ± 0.4 mSv, P = 0.003). Optimal tube voltage selection with the guidance of an automatic exposure control system in 320-ADCT coronary angiography allows substantial radiation reduction without significant impairment of image quality, compared to the results obtained using a BMI-based protocol.
Automated pharmaceutical tablet coating layer evaluation of optical coherence tomography images
NASA Astrophysics Data System (ADS)
Markl, Daniel; Hannesschläger, Günther; Sacher, Stephan; Leitner, Michael; Khinast, Johannes G.; Buchsbaum, Andreas
2015-03-01
Film coating of pharmaceutical tablets is often applied to influence the drug release behaviour. The coating characteristics such as thickness and uniformity are critical quality parameters, which need to be precisely controlled. Optical coherence tomography (OCT) shows not only high potential for off-line quality control of film-coated tablets but also for in-line monitoring of coating processes. However, an in-line quality control tool must be able to determine coating thickness measurements automatically and in real-time. This study proposes an automatic thickness evaluation algorithm for bi-convex tables, which provides about 1000 thickness measurements within 1 s. Beside the segmentation of the coating layer, optical distortions due to refraction of the beam by the air/coating interface are corrected. Moreover, during in-line monitoring the tablets might be in oblique orientation, which needs to be considered in the algorithm design. Experiments were conducted where the tablet was rotated to specified angles. Manual and automatic thickness measurements were compared for varying coating thicknesses, angles of rotations, and beam displacements (i.e. lateral displacement between successive depth scans). The automatic thickness determination algorithm provides highly accurate results up to an angle of rotation of 30°. The computation time was reduced to 0.53 s for 700 thickness measurements by introducing feasibility constraints in the algorithm.
NASA Astrophysics Data System (ADS)
Pellegrin, F.; Jeram, B.; Haucke, J.; Feyrin, S.
2016-07-01
The paper describes the introduction of a new automatized build and test infrastructure, based on the open-source software Jenkins1, into the ESO Very Large Telescope control software to replace the preexisting in-house solution. A brief introduction to software quality practices is given, a description of the previous solution, the limitations of it and new upcoming requirements. Modifications required to adapt the new system are described, how these were implemented to current software and the results obtained. An overview on how the new system may be used in future projects is also presented.
NASA Astrophysics Data System (ADS)
Meng, Fei; Tao, Gang; Zhang, Tao; Hu, Yihuai; Geng, Peng
2015-08-01
Shifting quality is a crucial factor in all parts of the automobile industry. To ensure an optimal gear shifting strategy with best fuel economy for a stepped automatic transmission, the controller should be designed to meet the challenge of lacking of a feedback sensor to measure the relevant variables. This paper focuses on a new kind of automatic transmission using proportional solenoid valve to control the clutch pressure, a speed difference of the clutch based control strategy is designed for the shift control during the inertia phase. First, the mechanical system is shown and the system dynamic model is built. Second, the control strategy is designed based on the characterization analysis of models which are derived from dynamics of the drive line and electro-hydraulic actuator. Then, the controller uses conventional Proportional-Integral-Derivative control theory, and a robust two-degree-of-freedom controller is also carried out to determine the optimal control parameters to further improve the system performance. Finally, the designed control strategy with different controller is implemented on a simulation model. The compared results show that the speed difference of clutch can track the desired trajectory well and improve the shift quality effectively.
Relevance of Google-customized search engine vs. CISMeF quality-controlled health gateway.
Gehanno, Jean-François; Kerdelhue, Gaétan; Sakji, Saoussen; Massari, Philippe; Joubert, Michel; Darmoni, Stéfan J
2009-01-01
CISMeF (acronym for Catalog and Index of French Language Health Resources on the Internet) is a quality-controlled health gateway conceived to catalog and index the most important and quality-controlled sources of institutional health information in French. The goal of this study is to compare the relevance of results provided by this gateway from a small set of documents selected and described by human experts to those provided by a search engine from a large set of automatically indexed and ranked resources. The Google-Customized search engine (CSE) was used. The evaluation was made using the 10th first results of 15 queries and two blinded physician evaluators. There was no significant difference between the relevance of information retrieval in CISMeF and Google CSE. In conclusion, automatic indexing does not lead to lower relevance than a manual MeSH indexing and may help to cope with the increasing number of references to be indexed in a controlled health quality gateway.
Improving labeling efficiency in automatic quality control of MRSI data.
Pedrosa de Barros, Nuno; McKinley, Richard; Wiest, Roland; Slotboom, Johannes
2017-12-01
To improve the efficiency of the labeling task in automatic quality control of MR spectroscopy imaging data. 28'432 short and long echo time (TE) spectra (1.5 tesla; point resolved spectroscopy (PRESS); repetition time (TR)= 1,500 ms) from 18 different brain tumor patients were labeled by two experts as either accept or reject, depending on their quality. For each spectrum, 47 signal features were extracted. The data was then used to run several simulations and test an active learning approach using uncertainty sampling. The performance of the classifiers was evaluated as a function of the number of patients in the training set, number of spectra in the training set, and a parameter α used to control the level of classification uncertainty required for a new spectrum to be selected for labeling. The results showed that the proposed strategy allows reductions of up to 72.97% for short TE and 62.09% for long TE in the amount of data that needs to be labeled, without significant impact in classification accuracy. Further reductions are possible with significant but minimal impact in performance. Active learning using uncertainty sampling is an effective way to increase the labeling efficiency for training automatic quality control classifiers. Magn Reson Med 78:2399-2405, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Feichtinger, Michael; Eder, Hans; Holl, Alexander; Körner, Eva; Zmugg, Gerda; Aigner, Reingard; Fazekas, Franz; Ott, Erwin
2007-07-01
In the presurgical evaluation of patients with partial epilepsy, the ictal single photon emission computed tomography (SPECT) is a useful noninvasive diagnostic tool for seizure focus localization. To achieve optimal SPECT scan quality, ictal tracer injection should be carried out as quickly as possible after the seizure onset and under highest safety conditions possible. Compared to the commonly used manual injection, an automatic administration of the radioactive tracer may provide higher quality standards for this procedure. In this study, therefore, we retrospectively analyzed efficiency and safety of an automatic injection system for ictal SPECT tracer application. Over a 31-month period, 26 patients underwent ictal SPECT by use of an automatic remote-controlled injection pump originally designed for CT-contrast agent application. Various factors were reviewed, including latency of ictal injection, radiation safety parameters, and ictal seizure onset localizing value. Times between seizure onset and tracer injection ranged between 3 and 48 s. In 21 of 26 patients ictal SPECT supported the localization of the epileptogenic focus in the course of the presurgical evaluation. In all cases ictal SPECT tracer injection was performed with a high degree of safety to patients and staff. Ictal SPECT by use of a remote-controlled CT-contrast agent injection system provides a high scan quality and is a safe and confirmatory presurgical evaluation technique in the epilepsy-monitoring unit.
The research of automatic speed control algorithm based on Green CBTC
NASA Astrophysics Data System (ADS)
Lin, Ying; Xiong, Hui; Wang, Xiaoliang; Wu, Youyou; Zhang, Chuanqi
2017-06-01
Automatic speed control algorithm is one of the core technologies of train operation control system. It’s a typical multi-objective optimization control algorithm, which achieve the train speed control for timing, comfort, energy-saving and precise parking. At present, the train speed automatic control technology is widely used in metro and inter-city railways. It has been found that the automatic speed control technology can effectively reduce the driver’s intensity, and improve the operation quality. However, the current used algorithm is poor at energy-saving, even not as good as manual driving. In order to solve the problem of energy-saving, this paper proposes an automatic speed control algorithm based on Green CBTC system. Based on the Green CBTC system, the algorithm can adjust the operation status of the train to improve the efficient using rate of regenerative braking feedback energy while ensuring the timing, comfort and precise parking targets. Due to the reason, the energy-using of Green CBTC system is lower than traditional CBTC system. The simulation results show that the algorithm based on Green CBTC system can effectively reduce the energy-using due to the improvement of the using rate of regenerative braking feedback energy.
PLC based automatic control of pasteurize mix in ice cream production
NASA Astrophysics Data System (ADS)
Yao, Xudong; Liang, Kai
2013-03-01
This paper describes the automatic control device of pasteurized mix in the ice cream production process.We design a scheme of control system using FBD program language and develop the programmer in the STEP 7-Micro/WIN software, check for any bugs before downloading into PLC .These developed devices will able to provide flexibility and accuracy to control the step of pasteurized mix. The operator just Input the duration and temperature of pasteurized mix through control panel. All the steps will finish automatically without any intervention in a preprogrammed sequence stored in programmable logic controller (PLC). With the help of this equipment we not only can control the quality of ice cream for various conditions, but also can simplify the production process. This control system is inexpensive and can be widely used in ice cream production industry.
Improving the Quality of Welding Seam of Automatic Welding of Buckets Based on TCP
NASA Astrophysics Data System (ADS)
Hu, Min
2018-02-01
Since February 2014, the welding defects of the automatic welding line of buckets have been frequently appeared. The average repair time of each bucket is 26min, which seriously affects the production efficiency and welding quality. We conducted troubleshooting, and found the main reasons for the welding defects of the buckets were the deviations of the center points of the robot tools and the poor quality of the locating welding. We corrected the gripper, welding torch, and accuracy of repeat positioning of robots to control the quality of positioning welding. The welding defect rate of buckets was reduced greatly, ensuring the production efficiency and welding quality.
AfterQC: automatic filtering, trimming, error removing and quality control for fastq data.
Chen, Shifu; Huang, Tanxiao; Zhou, Yanqing; Han, Yue; Xu, Mingyan; Gu, Jia
2017-03-14
Some applications, especially those clinical applications requiring high accuracy of sequencing data, usually have to face the troubles caused by unavoidable sequencing errors. Several tools have been proposed to profile the sequencing quality, but few of them can quantify or correct the sequencing errors. This unmet requirement motivated us to develop AfterQC, a tool with functions to profile sequencing errors and correct most of them, plus highly automated quality control and data filtering features. Different from most tools, AfterQC analyses the overlapping of paired sequences for pair-end sequencing data. Based on overlapping analysis, AfterQC can detect and cut adapters, and furthermore it gives a novel function to correct wrong bases in the overlapping regions. Another new feature is to detect and visualise sequencing bubbles, which can be commonly found on the flowcell lanes and may raise sequencing errors. Besides normal per cycle quality and base content plotting, AfterQC also provides features like polyX (a long sub-sequence of a same base X) filtering, automatic trimming and K-MER based strand bias profiling. For each single or pair of FastQ files, AfterQC filters out bad reads, detects and eliminates sequencer's bubble effects, trims reads at front and tail, detects the sequencing errors and corrects part of them, and finally outputs clean data and generates HTML reports with interactive figures. AfterQC can run in batch mode with multiprocess support, it can run with a single FastQ file, a single pair of FastQ files (for pair-end sequencing), or a folder for all included FastQ files to be processed automatically. Based on overlapping analysis, AfterQC can estimate the sequencing error rate and profile the error transform distribution. The results of our error profiling tests show that the error distribution is highly platform dependent. Much more than just another new quality control (QC) tool, AfterQC is able to perform quality control, data filtering, error profiling and base correction automatically. Experimental results show that AfterQC can help to eliminate the sequencing errors for pair-end sequencing data to provide much cleaner outputs, and consequently help to reduce the false-positive variants, especially for the low-frequency somatic mutations. While providing rich configurable options, AfterQC can detect and set all the options automatically and require no argument in most cases.
2014-01-01
Background Previous efforts such as Assessing Care of Vulnerable Elders (ACOVE) provide quality indicators for assessing the care of elderly patients, but thus far little has been done to leverage this knowledge to improve care for these patients. We describe a clinical decision support system to improve general practitioner (GP) adherence to ACOVE quality indicators and a protocol for investigating impact on GPs’ adherence to the rules. Design We propose two randomized controlled trials among a group of Dutch GP teams on adherence to ACOVE quality indicators. In both trials a clinical decision support system provides un-intrusive feedback appearing as a color-coded, dynamically updated, list of items needing attention. The first trial pertains to real-time automatically verifiable rules. The second trial concerns non-automatically verifiable rules (adherence cannot be established by the clinical decision support system itself, but the GPs report whether they will adhere to the rules). In both trials we will randomize teams of GPs caring for the same patients into two groups, A and B. For the automatically verifiable rules, group A GPs receive support only for a specific inter-related subset of rules, and group B GPs receive support only for the remainder of the rules. For non-automatically verifiable rules, group A GPs receive feedback framed as actions with positive consequences, and group B GPs receive feedback framed as inaction with negative consequences. GPs indicate whether they adhere to non-automatically verifiable rules. In both trials, the main outcome measure is mean adherence, automatically derived or self-reported, to the rules. Discussion We relied on active end-user involvement in selecting the rules to support, and on a model for providing feedback displayed as color-coded real-time messages concerning the patient visiting the GP at that time, without interrupting the GP’s workflow with pop-ups. While these aspects are believed to increase clinical decision support system acceptance and its impact on adherence to the selected clinical rules, systems with these properties have not yet been evaluated. Trial registration Controlled Trials NTR3566 PMID:24642339
Causes of cine image quality deterioration in cardiac catheterization laboratories.
Levin, D C; Dunham, L R; Stueve, R
1983-10-01
Deterioration of cineangiographic image quality can result from malfunctions or technical errors at a number of points along the cine imaging chain: generator and automatic brightness control, x-ray tube, x-ray beam geometry, image intensifier, optics, cine camera, cine film, film processing, and cine projector. Such malfunctions or errors can result in loss of image contrast, loss of spatial resolution, improper control of film optical density (brightness), or some combination thereof. While the electronic and photographic technology involved is complex, physicians who perform cardiac catheterization should be conversant with the problems and what can be done to solve them. Catheterization laboratory personnel have control over a number of factors that directly affect image quality, including radiation dose rate per cine frame, kilovoltage or pulse width (depending on type of automatic brightness control), cine run time, selection of small or large focal spot, proper object-intensifier distance and beam collimation, aperture of the cine camera lens, selection of cine film, processing temperature, processing immersion time, and selection of developer.
An evaluation of automatic control system concepts for general aviation airplanes
NASA Technical Reports Server (NTRS)
Stewart, E. C.; Ragsdale, W. A.; Wunschel, A. J.
1988-01-01
A piloted simulation study of automatic longitudinal control systems for general aviation airplanes has been conducted. These automatic control systems were designed to make the simulated airplane easy to fly for a beginning or infrequent pilot. Different control systems are presented and their characteristics are documented. In a conventional airplane control system each cockpit controller commands combinations of both the airspeed and the vertical speed. The best system in the present study decoupled the airspeed and vertical speed responses to cockpit throttle inputs. That is, the cockpit throttle lever commanded only airspeed responses, and the longitudinal wheel position commanded only vertical speed responses. This system significantly reduced the pilot workload throughout an entire mission of the airplane from takeoff to landing. An important feature of the automatic system was that neither changing flap position nor maneuvering in steeply banked turns affected either the airspeed or the vertical speed. All the pilots who flew the control system simulation were favorably impressed with the very low workload and the excellent handling qualities of the simulated airplane.
40 CFR Appendix F to Part 60 - Quality Assurance Procedures
Code of Federal Regulations, 2012 CFR
2012-07-01
... automatically adjust the data to the corrected calibration values (e.g., microprocessor control) must be... calibration values (e.g., microprocessor control), you must program your PM CEMS to record the unadjusted...
Automatic Welding of Stainless Steel Tubing
NASA Technical Reports Server (NTRS)
Clautice, W. E.
1978-01-01
To determine if the use of automatic welding would allow reduction of the radiographic inspection requirement, and thereby reduce fabrication costs, a series of welding tests were performed. In these tests an automatic welder was used on stainless steel tubing of 1/2, 3/4, and 1/2 inch diameter size. The optimum parameters were investigated to determine how much variation from optimum in machine settings could be tolerate and still result in a good quality weld. The process variables studied were the welding amperes, the revolutions per minute as a function of the circumferential weld travel speed, and the shielding gas flow. The investigation showed that the close control of process variables in conjunction with a thorough visual inspection of welds can be relied upon as an acceptable quality assurance procedure, thus permitting the radiographic inspection to be reduced by a large percentage when using the automatic process.
Research progress of on-line automatic monitoring of chemical oxygen demand (COD) of water
NASA Astrophysics Data System (ADS)
Cai, Youfa; Fu, Xing; Gao, Xiaolu; Li, Lianyin
2018-02-01
With the increasingly stricter control of pollutant emission in China, the on-line automatic monitoring of water quality is particularly urgent. The chemical oxygen demand (COD) is a comprehensive index to measure the contamination caused by organic matters, and thus it is taken as one important index of energy-saving and emission reduction in China’s “Twelve-Five” program. So far, the COD on-line automatic monitoring instrument has played an important role in the field of sewage monitoring. This paper reviews the existing methods to achieve on-line automatic monitoring of COD, and on the basis, points out the future trend of the COD on-line automatic monitoring instruments.
NASA Astrophysics Data System (ADS)
Giles, D. M.; Holben, B. N.; Smirnov, A.; Eck, T. F.; Slutsker, I.; Sorokin, M. G.; Espenak, F.; Schafer, J.; Sinyuk, A.
2015-12-01
The Aerosol Robotic Network (AERONET) has provided a database of aerosol optical depth (AOD) measured by surface-based Sun/sky radiometers for over 20 years. AERONET provides unscreened (Level 1.0) and automatically cloud cleared (Level 1.5) AOD in near real-time (NRT), while manually inspected quality assured (Level 2.0) AOD are available after instrument field deployment (Smirnov et al., 2000). The growing need for NRT quality controlled aerosol data has become increasingly important. Applications of AERONET NRT data include the satellite evaluation (e.g., MODIS, VIIRS, MISR, OMI), data synergism (e.g., MPLNET), verification of aerosol forecast models and reanalysis (e.g., GOCART, ICAP, NAAPS, MERRA), input to meteorological models (e.g., NCEP, ECMWF), and field campaign support (e.g., KORUS-AQ, ORACLES). In response to user needs for quality controlled NRT data sets, the new Version 3 (V3) Level 1.5V product was developed with similar quality controls as those applied by hand to the Version 2 (V2) Level 2.0 data set. The AERONET cloud screened (Level 1.5) NRT AOD database can be significantly impacted by data anomalies. The most significant data anomalies include AOD diurnal dependence due to contamination or obstruction of the sensor head windows, anomalous AOD spectral dependence due to problems with filter degradation, instrument gains, or non-linear changes in calibration, and abnormal changes in temperature sensitive wavelengths (e.g., 1020nm) in response to anomalous sensor head temperatures. Other less common AOD anomalies result from loose filters, uncorrected clock shifts, connection and electronic issues, and various solar eclipse episodes. Automatic quality control algorithms are applied to the new V3 Level 1.5 database to remove NRT AOD anomalies and produce the new AERONET V3 Level 1.5V AOD product. Results of the quality control algorithms are presented and the V3 Level 1.5V AOD database is compared to the V2 Level 2.0 AOD database.
NASA Technical Reports Server (NTRS)
Wilckens, V.
1972-01-01
Present information display concepts for pilot landing guidance are outlined considering manual control as well as substitution of man by fully competent automatics. Display improvements are achieved by compressing the distributed indicators into an accumulative display and thus reducing information scanning. Complete integration of quantitative indications, outer loop information, and real world display in a pictorial information channel geometry constitutes an interface with human ability to differentiate and integrate for optimal manual control of the aircraft.
Wallace, Adam N; Vyhmeister, Ross; Bagade, Swapnil; Chatterjee, Arindam; Hicks, Brandon; Ramirez-Giraldo, Juan Carlos; McKinstry, Robert C
2015-06-01
Cerebrospinal fluid shunts are primarily used for the treatment of hydrocephalus. Shunt complications may necessitate multiple non-contrast head CT scans resulting in potentially high levels of radiation dose starting at an early age. A new head CT protocol using automatic exposure control and automated tube potential selection has been implemented at our institution to reduce radiation exposure. The purpose of this study was to evaluate the reduction in radiation dose achieved by this protocol compared with a protocol with fixed parameters. A retrospective sample of 60 non-contrast head CT scans assessing for cerebrospinal fluid shunt malfunction was identified, 30 of which were performed with each protocol. The radiation doses of the two protocols were compared using the volume CT dose index and dose length product. The diagnostic acceptability and quality of each scan were evaluated by three independent readers. The new protocol lowered the average volume CT dose index from 15.2 to 9.2 mGy representing a 39 % reduction (P < 0.01; 95 % CI 35-44 %) and lowered the dose length product from 259.5 to 151.2 mGy/cm representing a 42 % reduction (P < 0.01; 95 % CI 34-50 %). The new protocol produced diagnostically acceptable scans with comparable image quality to the fixed parameter protocol. A pediatric shunt non-contrast head CT protocol using automatic exposure control and automated tube potential selection reduced patient radiation dose compared with a fixed parameter protocol while producing diagnostic images of comparable quality.
Chmielewski, Witold X; Beste, Christian
2017-02-01
In everyday life successful acting often requires to inhibit automatic responses that might not be appropriate in the current situation. These response inhibition processes have been shown to become aggravated with increasing automaticity of pre-potent response tendencies. Likewise, it has been shown that inhibitory processes are complicated by a concurrent engagement in additional cognitive control processes (e.g. conflicting monitoring). Therefore, opposing processes (i.e. automaticity and cognitive control) seem to strongly impact response inhibition. However, possible interactive effects of automaticity and cognitive control for the modulation of response inhibition processes have yet not been examined. In the current study we examine this question using a novel experimental paradigm combining a Go/NoGo with a Simon task in a system neurophysiological approach combining EEG recordings with source localization analyses. The results show that response inhibition is less accurate in non-conflicting than in conflicting stimulus-response mappings. Thus it seems that conflicts and the resulting engagement in conflict monitoring processes, as reflected in the N2 amplitude, may foster response inhibition processes. This engagement in conflict monitoring processes leads to an increase in cognitive control, as reflected by an increased activity in the anterior and posterior cingulate areas, while simultaneously the automaticity of response tendencies is decreased. Most importantly, this study suggests that the quality of conflict processes in anterior cingulate areas and especially the resulting interaction of cognitive control and automaticity of pre-potent response tendencies are important factors to consider, when it comes to the modulation of response inhibition processes. Copyright © 2016 Elsevier Inc. All rights reserved.
Aozan: an automated post-sequencing data-processing pipeline.
Perrin, Sandrine; Firmo, Cyril; Lemoine, Sophie; Le Crom, Stéphane; Jourdren, Laurent
2017-07-15
Data management and quality control of output from Illumina sequencers is a disk space- and time-consuming task. Thus, we developed Aozan to automatically handle data transfer, demultiplexing, conversion and quality control once a run has finished. This software greatly improves run data management and the monitoring of run statistics via automatic emails and HTML web reports. Aozan is implemented in Java and Python, supported on Linux systems, and distributed under the GPLv3 License at: http://www.outils.genomique.biologie.ens.fr/aozan/ . Aozan source code is available on GitHub: https://github.com/GenomicParisCentre/aozan . aozan@biologie.ens.fr. © The Author (2017). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com
A low-cost inertial smoothing system for landing approach guidance
NASA Technical Reports Server (NTRS)
Niessen, F. R.
1973-01-01
Accurate position and velocity information with low noise content for instrument approaches and landings is required for both control and display applications. In a current VTOL automatic instrument approach and landing research program, radar-derived landing guidance position reference signals, which are noisy, have been mixed with acceleration information derived from low-cost onboard sensors to provide high-quality position and velocity information. An in-flight comparison of signal quality and accuracy has shown good agreement between the low-cost inertial smoothing system and an aided inertial navigation system. Furthermore, the low-cost inertial smoothing system has been proven to be satisfactory in control and display system applications for both automatic and pilot-in-the-loop instrument approaches and landings.
Nitrosi, Andrea; Bertolini, Marco; Borasi, Giovanni; Botti, Andrea; Barani, Adriana; Rivetti, Stefano; Pierotti, Luisa
2009-12-01
Ideally, medical x-ray imaging systems should be designed to deliver maximum image quality at an acceptable radiation risk to the patient. Quality assurance procedures are employed to ensure that these standards are maintained. A quality control protocol for direct digital radiography (DDR) systems is described and discussed. Software to automatically process and analyze the required images was developed. In this paper, the initial results obtained on equipment of different DDR manufacturers were reported. The protocol was developed to highlight even small discrepancies in standard operating performance.
Development and Perceptual Evaluation of Amplitude-Based F0 Control in Electrolarynx Speech
ERIC Educational Resources Information Center
Saikachi, Yoko; Stevens, Kenneth N.; Hillman, Robert E.
2009-01-01
Purpose: Current electrolarynx (EL) devices produce a mechanical speech quality that has been largely attributed to the lack of natural fundamental frequency (F0) variation. In order to improve the quality of EL speech, in the present study the authors aimed to develop and evaluate an automatic F0 control scheme, in which F0 was modulated based on…
Quality Control of True Height Profiles Obtained Automatically from Digital Ionograms.
1982-05-01
nece.,ssary and Identify by block number) Ionosphere Digisonde Electron Density Profile Ionogram Autoscaling ARTIST 2 , ABSTRACT (Continue on reverae...analysis technique currently used with the ionogram traces scaled automatically by the ARTIST software [Reinisch and Huang, 1983; Reinisch et al...19841, and the generalized polynomial analysis technique POLAN [Titheridge, 1985], using the same ARTIST -identified ionogram traces. 2. To determine how
HVAC System Automatic Controls and Indoor Air Quality in Schools. Technical Bulletin.
ERIC Educational Resources Information Center
Wheeler, Arthur E.
Fans, motors, coils, and other control components enable a heating, ventilating, and air-conditioning (HVAC) system to function smoothly. An explanation of these control components and how they make school HVAC systems work is provided. Different systems may be compared by counting the number of controlled devices that are required. Control…
Control of the TSU 2-m automatic telescope
NASA Astrophysics Data System (ADS)
Eaton, Joel A.; Williamson, Michael H.
2004-09-01
Tennessee State University is operating a 2-m automatic telescope for high-dispersion spectroscopy. The alt-azimuth telescope is fiber-coupled to a conventional echelle spectrograph with two resolutions (R=30,000 and 70,000). We control this instrument with four computers running linux and communicating over ethernet through the UDP protocol. A computer physically located on the telescope handles the acquisition and tracking of stars. We avoid the need for real-time programming in this application by periodically latching the positions of the axes in a commercial motion controller and the time in a GPS receiver. A second (spectrograph) computer sets up the spectrograph and runs its CCD, a third (roof) computer controls the roll-off roof and front flap of the telescope enclosure, and the fourth (executive) computer makes decisions about which stars to observe and when to close the observatory for bad weather. The only human intervention in the telescope's operation involves changing the observing program, copying data back to TSU, and running quality-control checks on the data. It has been running reliably in this completely automatic, unattended mode for more than a year with all day-to-day adminsitration carried out over the Internet. To support automatic operation, we have written a number of useful tools to predict and analyze what the telescope does. These include a simulator that predicts roughly how the telescope will operate on a given night, a quality-control program to parse logfiles from the telescope and identify problems, and a rescheduling program that calculates new priorities to keep the frequency of observation for the various stars roughly as desired. We have also set up a database to keep track of the tens of thousands of spectra we expect to get each year.
Driving photomask supplier quality through automation
NASA Astrophysics Data System (ADS)
Russell, Drew; Espenscheid, Andrew
2007-10-01
In 2005, Freescale Semiconductor's newly centralized mask data prep organization (MSO) initiated a project to develop an automated global quality validation system for photomasks delivered to Freescale Semiconductor fabs. The system handles Certificate of Conformance (CofC) quality metric collection, validation, reporting and an alert system for all photomasks shipped to Freescale fabs from all qualified global suppliers. The completed system automatically collects 30+ quality metrics for each photomask shipped. Other quality metrics are generated from the collected data and quality metric conformance is automatically validated to specifications or control limits with failure alerts emailed to fab photomask and mask data prep engineering. A quality data warehouse stores the data for future analysis, which is performed quarterly. The improved access to data provided by the system has improved Freescale engineers' ability to spot trends and opportunities for improvement with our suppliers' processes. This paper will review each phase of the project, current system capabilities and quality system benefits for both our photomask suppliers and Freescale.
Automatic quality control in clinical (1)H MRSI of brain cancer.
Pedrosa de Barros, Nuno; McKinley, Richard; Knecht, Urspeter; Wiest, Roland; Slotboom, Johannes
2016-05-01
MRSI grids frequently show spectra with poor quality, mainly because of the high sensitivity of MRS to field inhomogeneities. These poor quality spectra are prone to quantification and/or interpretation errors that can have a significant impact on the clinical use of spectroscopic data. Therefore, quality control of the spectra should always precede their clinical use. When performed manually, quality assessment of MRSI spectra is not only a tedious and time-consuming task, but is also affected by human subjectivity. Consequently, automatic, fast and reliable methods for spectral quality assessment are of utmost interest. In this article, we present a new random forest-based method for automatic quality assessment of (1)H MRSI brain spectra, which uses a new set of MRS signal features. The random forest classifier was trained on spectra from 40 MRSI grids that were classified as acceptable or non-acceptable by two expert spectroscopists. To account for the effects of intra-rater reliability, each spectrum was rated for quality three times by each rater. The automatic method classified these spectra with an area under the curve (AUC) of 0.976. Furthermore, in the subset of spectra containing only the cases that were classified every time in the same way by the spectroscopists, an AUC of 0.998 was obtained. Feature importance for the classification was also evaluated. Frequency domain skewness and kurtosis, as well as time domain signal-to-noise ratios (SNRs) in the ranges 50-75 ms and 75-100 ms, were the most important features. Given that the method is able to assess a whole MRSI grid faster than a spectroscopist (approximately 3 s versus approximately 3 min), and without loss of accuracy (agreement between classifier trained with just one session and any of the other labelling sessions, 89.88%; agreement between any two labelling sessions, 89.03%), the authors suggest its implementation in the clinical routine. The method presented in this article was implemented in jMRUI's SpectrIm plugin. Copyright © 2016 John Wiley & Sons, Ltd.
Apparatus and method for combusting low quality fuel
Brushwood, John Samuel; Pillsbury, Paul; Foote, John; Heilos, Andreas
2003-11-04
A gas turbine (12) capable of combusting a low quality gaseous fuel having a ratio of flammability limits less than 2, or a heat value below 100 BTU/SCF. A high quality fuel is burned simultaneously with the low quality fuel to eliminate instability in the combustion flame. A sensor (46) is used to monitor at least one parameter of the flame indicative of instability. A controller (50) having the sensor signal (48) as input is programmed to control the relative flow rates of the low quality and high quality fuels. When instability is detected, the flow rate of high quality fuel is automatically increased in relation to the flow rate of low quality fuel to restore stability.
Scheduling algorithms for automatic control systems for technological processes
NASA Astrophysics Data System (ADS)
Chernigovskiy, A. S.; Tsarev, R. Yu; Kapulin, D. V.
2017-01-01
Wide use of automatic process control systems and the usage of high-performance systems containing a number of computers (processors) give opportunities for creation of high-quality and fast production that increases competitiveness of an enterprise. Exact and fast calculations, control computation, and processing of the big data arrays - all of this requires the high level of productivity and, at the same time, minimum time of data handling and result receiving. In order to reach the best time, it is necessary not only to use computing resources optimally, but also to design and develop the software so that time gain will be maximal. For this purpose task (jobs or operations), scheduling techniques for the multi-machine/multiprocessor systems are applied. Some of basic task scheduling methods for the multi-machine process control systems are considered in this paper, their advantages and disadvantages come to light, and also some usage considerations, in case of the software for automatic process control systems developing, are made.
NASA Technical Reports Server (NTRS)
Churchill, G. B.; Gerdes, R. M.
1984-01-01
The design criteria and control and handling qualities of the Automatic Flight Control System (AFCS), developed in the framework of the XV-15 tilt-rotor research aircraft, are evaluated, differentiating between the stability and control criteria. A technically aggressive SCAS control law was implemented, demonstrating that significant benefits accrue when stability criteria are separated from design criteria; the design analyses for application of the control law are presented, and the limit bandwidth for stabilization in hovering flight is shown to be defined by rotor or control lag functions. Flight tests of the aircraft resulted in a rating of 3 on the Cooper-Harper scale; a possibility of achieving a rating of 2 is expected if the system is applied to the yaw and heave control modes.
Singh, Ravendra; Román-Ospino, Andrés D; Romañach, Rodolfo J; Ierapetritou, Marianthi; Ramachandran, Rohit
2015-11-10
The pharmaceutical industry is strictly regulated, where precise and accurate control of the end product quality is necessary to ensure the effectiveness of the drug products. For such control, the process and raw materials variability ideally need to be fed-forward in real time into an automatic control system so that a proactive action can be taken before it can affect the end product quality. Variations in raw material properties (e.g., particle size), feeder hopper level, amount of lubrication, milling and blending action, applied shear in different processing stages can affect the blend density significantly and thereby tablet weight, hardness and dissolution. Therefore, real time monitoring of powder bulk density variability and its incorporation into the automatic control system so that its effect can be mitigated proactively and efficiently is highly desired. However, real time monitoring of powder bulk density is still a challenging task because of different level of complexities. In this work, powder bulk density which has a significant effect on the critical quality attributes (CQA's) has been monitored in real time in a pilot-plant facility, using a NIR sensor. The sensitivity of the powder bulk density on critical process parameters (CPP's) and CQA's has been analyzed and thereby feed-forward controller has been designed. The measured signal can be used for feed-forward control so that the corrective actions on the density variations can be taken before they can influence the product quality. The coupled feed-forward/feed-back control system demonstrates improved control performance and improvements in the final product quality in the presence of process and raw material variations. Copyright © 2015 Elsevier B.V. All rights reserved.
Effects of control laws and relaxed static stability on vertical ride quality of flexible aircraft
NASA Technical Reports Server (NTRS)
Roberts, P. A.; Swaim, R. L.; Schmidt, D. K.; Hinsdale, A. J.
1977-01-01
State variable techniques are utilized to generate the RMS vertical load factors for the B-52H and B-1 bombers at low level, mission critical, cruise conditions. A ride quality index is proposed to provide meaningful comparisons between different controls or conditions. Ride quality is shown to be relatively invariant under various popular control laws. Handling quality variations are shown to be major contributors to ride quality variations on both vehicles. Relaxed static stability is artificially implemented on the study vehicles to investigate its effects on ride quality. The B-52H ride quality is generally degraded when handling characteristics are automatically restored by a feedback control to the original values from relaxed stability conditions. The B-1 airplane shows little ride quality sensitivity to the same analysis due to the small rigid body contribution to load factors at the flight condition investigated.
Moderators of the Relationship between Implicit and Explicit Evaluation
Nosek, Brian A.
2005-01-01
Automatic and controlled modes of evaluation sometimes provide conflicting reports of the quality of social objects. This paper presents evidence for four moderators of the relationship between automatic (implicit) and controlled (explicit) evaluations. Implicit and explicit preferences were measured for a variety of object pairs using a large sample. The average correlation was r = .36, and 52 of the 57 object pairs showed a significant positive correlation. Results of multilevel modeling analyses suggested that: (a) implicit and explicit preferences are related, (b) the relationship varies as a function of the objects assessed, and (c) at least four variables moderate the relationship – self-presentation, evaluative strength, dimensionality, and distinctiveness. The variables moderated implicit-explicit correspondence across individuals and accounted for much of the observed variation across content domains. The resulting model of the relationship between automatic and controlled evaluative processes is grounded in personal experience with the targets of evaluation. PMID:16316292
Gosch, D; Ratzmer, A; Berauer, P; Kahn, T
2007-09-01
The objective of this study was to examine the extent to which the image quality on mobile C-arms can be improved by an innovative exposure rate control system (grid control). In addition, the possible dose reduction in the pulsed fluoroscopy mode using 25 pulses/sec produced by automatic adjustment of the pulse rate through motion detection was to be determined. As opposed to conventional exposure rate control systems, which use a measuring circle in the center of the field of view, grid control is based on a fine mesh of square cells which are overlaid on the entire fluoroscopic image. The system uses only those cells for exposure control that are covered by the object to be visualized. This is intended to ensure optimally exposed images, regardless of the size, shape and position of the object to be visualized. The system also automatically detects any motion of the object. If a pulse rate of 25 pulses/sec is selected and no changes in the image are observed, the pulse rate used for pulsed fluoroscopy is gradually reduced. This may decrease the radiation exposure. The influence of grid control on image quality was examined using an anthropomorphic phantom. The dose reduction achieved with the help of object detection was determined by evaluating the examination data of 146 patients from 5 different countries. The image of the static phantom made with grid control was always optimally exposed, regardless of the position of the object to be visualized. The average dose reduction when using 25 pulses/sec resulting from object detection and automatic down-pulsing was 21 %, and the maximum dose reduction was 60 %. Grid control facilitates C-arm operation, since optimum image exposure can be obtained independently of object positioning. Object detection may lead to a reduction in radiation exposure for the patient and operating staff.
A Batch Feeder for Inhomogeneous Bulk Materials
NASA Astrophysics Data System (ADS)
Vislov, I. S.; Kladiev, S. N.; Slobodyan, S. M.; Bogdan, A. M.
2016-04-01
The work includes the mechanical analysis of mechanical feeders and batchers that find application in various technological processes and industrial fields. Feeders are usually classified according to their design features into two groups: conveyor-type feeders and non-conveyor feeders. Batchers are used to batch solid bulk materials. Less frequently, they are used for liquids. In terms of a batching method, they are divided into volumetric and weighting batchers. Weighting batchers do not provide for sufficient batching accuracy. Automatic weighting batchers include a mass controlling sensor and systems for automatic material feed and automatic mass discharge control. In terms of operating principle, batchers are divided into gravitational batchers and batchers with forced feed of material using conveyors and pumps. Improved consumption of raw materials, decreased loss of materials, ease of use in automatic control systems of industrial facilities allows increasing the quality of technological processes and improve labor conditions. The batch feeder suggested by the authors is a volumetric batcher that has no comparable counterparts among conveyor-type feeders and allows solving the problem of targeted feeding of bulk material batches increasing reliability and hermeticity of the device.
NASA Astrophysics Data System (ADS)
Cipriani, L.; Fantini, F.; Bertacchi, S.
2014-06-01
Image-based modelling tools based on SfM algorithms gained great popularity since several software houses provided applications able to achieve 3D textured models easily and automatically. The aim of this paper is to point out the importance of controlling models parameterization process, considering that automatic solutions included in these modelling tools can produce poor results in terms of texture utilization. In order to achieve a better quality of textured models from image-based modelling applications, this research presents a series of practical strategies aimed at providing a better balance between geometric resolution of models from passive sensors and their corresponding (u,v) map reference systems. This aspect is essential for the achievement of a high-quality 3D representation, since "apparent colour" is a fundamental aspect in the field of Cultural Heritage documentation. Complex meshes without native parameterization have to be "flatten" or "unwrapped" in the (u,v) parameter space, with the main objective to be mapped with a single image. This result can be obtained by using two different strategies: the former automatic and faster, while the latter manual and time-consuming. Reverse modelling applications provide automatic solutions based on splitting the models by means of different algorithms, that produce a sort of "atlas" of the original model in the parameter space, in many instances not adequate and negatively affecting the overall quality of representation. Using in synergy different solutions, ranging from semantic aware modelling techniques to quad-dominant meshes achieved using retopology tools, it is possible to obtain a complete control of the parameterization process.
Long-term quality assurance of [(18)F]-fluorodeoxyglucose (FDG) manufacturing.
Gaspar, Ludovit; Reich, Michal; Kassai, Zoltan; Macasek, Fedor; Rodrigo, Luis; Kruzliak, Peter; Kovac, Peter
2016-01-01
Nine years of experience with 2286 commercial synthesis allowed us to deliver comprehensive information on the quality of (18)F-FDG production. Semi-automated FDG production line using Cyclone 18/9 machine (IBA Belgium), TRACERLab MXFDG synthesiser (GE Health, USA) using alkalic hydrolysis, grade "A" isolator with dispensing robotic unit (Tema Sinergie, Italy), and automatic control system under GAMP5 (minus2, Slovakia) was assessed by TQM tools as highly reliable aseptic production line, fully compliant with Good Manufacturing Practice and just-in-time delivery of FDG radiopharmaceutical. Fluoride-18 is received in steady yield and of very high radioactive purity. Synthesis yields exhibited high variance connected probably with quality of disposable cassettes and chemicals sets. Most performance non-conformities within the manufacturing cycle occur at mechanical nodes of dispensing unit. The long-term monitoring of 2286 commercial synthesis indicated high reliability of automatic synthesizers. Shewhart chart and ANOVA analysis showed that minor non-compliances occurred were mostly caused by the declinations of less experienced staff from standard operation procedures, and also by quality of automatic cassettes. Only 15 syntheses were found unfinished and in 4 cases the product was out-of-specification of European Pharmacopoeia. Most vulnerable step of manufacturing was dispensing and filling in grade "A" isolator. Its cleanliness and sterility was fully controlled under the investigated period by applying hydrogen peroxide vapours (VHP). Our experience with quality assurance in the production of [(18)F]-fluorodeoxyglucose (FDG) at production facility of BIONT based on TRACERlab MXFDG production module can be used for bench-marking of the emerging manufacturing and automated manufacturing systems.
Long-term quality assurance of [18F]-fluorodeoxyglucose (FDG) manufacturing
Gaspar, Ludovit; Reich, Michal; Kassai, Zoltan; Macasek, Fedor; Rodrigo, Luis; Kruzliak, Peter; Kovac, Peter
2016-01-01
Nine years of experience with 2286 commercial synthesis allowed us to deliver comprehensive information on the quality of 18F-FDG production. Semi-automated FDG production line using Cyclone 18/9 machine (IBA Belgium), TRACERLab MXFDG synthesiser (GE Health, USA) using alkalic hydrolysis, grade “A” isolator with dispensing robotic unit (Tema Sinergie, Italy), and automatic control system under GAMP5 (minus2, Slovakia) was assessed by TQM tools as highly reliable aseptic production line, fully compliant with Good Manufacturing Practice and just-in-time delivery of FDG radiopharmaceutical. Fluoride-18 is received in steady yield and of very high radioactive purity. Synthesis yields exhibited high variance connected probably with quality of disposable cassettes and chemicals sets. Most performance non-conformities within the manufacturing cycle occur at mechanical nodes of dispensing unit. The long-term monitoring of 2286 commercial synthesis indicated high reliability of automatic synthesizers. Shewhart chart and ANOVA analysis showed that minor non-compliances occurred were mostly caused by the declinations of less experienced staff from standard operation procedures, and also by quality of automatic cassettes. Only 15 syntheses were found unfinished and in 4 cases the product was out-of-specification of European Pharmacopoeia. Most vulnerable step of manufacturing was dispensing and filling in grade “A” isolator. Its cleanliness and sterility was fully controlled under the investigated period by applying hydrogen peroxide vapours (VHP). Our experience with quality assurance in the production of [18F]-fluorodeoxyglucose (FDG) at production facility of BIONT based on TRACERlab MXFDG production module can be used for bench-marking of the emerging manufacturing and automated manufacturing systems. PMID:27508102
Microcontroller based automatic temperature control for oyster mushroom plants
NASA Astrophysics Data System (ADS)
Sihombing, P.; Astuti, T. P.; Herriyance; Sitompul, D.
2018-03-01
In the cultivation of Oyster Mushrooms need special treatment because oyster mushrooms are susceptible to disease. Mushroom growth will be inhibited if the temperature and humidity are not well controlled because temperature and inertia can affect mold growth. Oyster mushroom growth usually will be optimal at temperatures around 22-28°C and humidity around 70-90%. This problem is often encountered in the cultivation of oyster mushrooms. Therefore it is very important to control the temperature and humidity of the room of oyster mushroom cultivation. In this paper, we developed an automatic temperature monitoring tool in the cultivation of oyster mushroom-based Arduino Uno microcontroller. We have designed a tool that will control the temperature and humidity automatically by Android Smartphone. If the temperature increased more than 28°C in the room of mushroom plants, then this tool will turn on the pump automatically to run water in order to lower the room temperature. And if the room temperature of mushroom plants below of 22°C, then the light will be turned on in order to heat the room. Thus the temperature in the room oyster mushrooms will remain stable so that the growth of oyster mushrooms can grow with good quality.
42 CFR 37.10 - Standards incorporated by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Department, Medical Physics Publishing, 4513 Vernon Blvd., Madison, WI 53705, http://www.aapm.org/pubs... Automatic Exposure Control Devices, published by the American Institute of Physics for AAPM, January 1985... Institute of Physics, July 1990, into § 37.44(g). (4) AAPM Report No. 74, Quality Control in Diagnostic...
42 CFR 37.10 - Standards incorporated by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Department, Medical Physics Publishing, 4513 Vernon Blvd., Madison, WI 53705, http://www.aapm.org/pubs... Automatic Exposure Control Devices, published by the American Institute of Physics for AAPM, January 1985... Institute of Physics, July 1990, into § 37.44(g). (4) AAPM Report No. 74, Quality Control in Diagnostic...
A quality score for coronary artery tree extraction results
NASA Astrophysics Data System (ADS)
Cao, Qing; Broersen, Alexander; Kitslaar, Pieter H.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke
2018-02-01
Coronary artery trees (CATs) are often extracted to aid the fully automatic analysis of coronary artery disease on coronary computed tomography angiography (CCTA) images. Automatically extracted CATs often miss some arteries or include wrong extractions which require manual corrections before performing successive steps. For analyzing a large number of datasets, a manual quality check of the extraction results is time-consuming. This paper presents a method to automatically calculate quality scores for extracted CATs in terms of clinical significance of the extracted arteries and the completeness of the extracted CAT. Both right dominant (RD) and left dominant (LD) anatomical statistical models are generated and exploited in developing the quality score. To automatically determine which model should be used, a dominance type detection method is also designed. Experiments are performed on the automatically extracted and manually refined CATs from 42 datasets to evaluate the proposed quality score. In 39 (92.9%) cases, the proposed method is able to measure the quality of the manually refined CATs with higher scores than the automatically extracted CATs. In a 100-point scale system, the average scores for automatically and manually refined CATs are 82.0 (+/-15.8) and 88.9 (+/-5.4) respectively. The proposed quality score will assist the automatic processing of the CAT extractions for large cohorts which contain both RD and LD cases. To the best of our knowledge, this is the first time that a general quality score for an extracted CAT is presented.
NASA Astrophysics Data System (ADS)
An, Shengpei; Hu, Tianyue; Liu, Yimou; Peng, Gengxin; Liang, Xianghao
2017-12-01
Static correction is a crucial step of seismic data processing for onshore play, which frequently has a complex near-surface condition. The effectiveness of the static correction depends on an accurate determination of first-arrival traveltimes. However, it is difficult to accurately auto-pick the first arrivals for data with low signal-to-noise ratios (SNR), especially for those measured in the area of the complex near-surface. The technique of the super-virtual interferometry (SVI) has the potential to enhance the SNR of first arrivals. In this paper, we develop the extended SVI with (1) the application of the reverse correlation to improve the capability of SNR enhancement at near-offset, and (2) the usage of the multi-domain method to partially overcome the limitation of current method, given insufficient available source-receiver combinations. Compared to the standard SVI, the SNR enhancement of the extended SVI can be up to 40%. In addition, we propose a quality control procedure, which is based on the statistical characteristics of multichannel recordings of first arrivals. It can auto-correct the mispicks, which might be spurious events generated by the SVI. This procedure is very robust, highly automatic and it can accommodate large data in batches. Finally, we develop one automatic first-arrival picking method to combine the extended SVI and the quality control procedure. Both the synthetic and the field data examples demonstrate that the proposed method is able to accurately auto-pick first arrivals in seismic traces with low SNR. The quality of the stacked seismic sections obtained from this method is much better than those obtained from an auto-picking method, which is commonly employed by the commercial software.
ERIC Educational Resources Information Center
Chounta, Irene-Angelica; Avouris, Nikolaos
2016-01-01
This paper presents the integration of a real time evaluation method of collaboration quality in a monitoring application that supports teachers in class orchestration. The method is implemented as an automatic rater of collaboration quality and studied in a real time scenario of use. We argue that automatic and semi-automatic methods which…
[Features of the maintenance of automated developing machines].
Koveshnikov, A I
1999-01-01
Based on his long-term own experience the author gives recommendations on the assembly, adjustment, operation, and preventive maintenance of automatic developing machines. Procedures are presented for evaluating the quality of X-ray films and controlling the activity of operating qualities of a developer while machining photographic materials. Troubles and malfunction of equipment and procedures for their elimination are shown to affect the quality of development of films.
Recent developments in smart freezing technology applied to fresh foods.
Xu, Ji-Cheng; Zhang, Min; Mujumdar, Arun S; Adhikari, Benu
2017-09-02
Due to the increased awareness of consumers in sensorial and nutritional quality of frozen foods, the freezing technology has to seek new and innovative technologies for better retaining the fresh like quality of foods. In this article, we review the recent developments in smart freezing technology applied to fresh foods. The application of these intelligent technologies and the associated underpinning concepts have greatly improved the quality of frozen foods and the freezing efficiency. These technologies are able to automatically collect the information in-line during freezing and help control the freezing process better. Smart freezing technology includes new and intelligent technologies and concepts applied to the pretreatment of the frozen product, freezing processes, cold chain logistics as well as warehouse management. These technologies enable real-time monitoring of quality during the freezing process and help improve product quality and freezing efficiency. We also provide a brief overview of several sensing technologies used to achieve automatic control of individual steps of freezing process. These sensing technologies include computer vision, electronic nose, electronic tongue, digital simulation, confocal laser, near infrared spectroscopy, nuclear magnetic resonance technology and ultrasound. Understanding of the mechanism of these new technologies will be helpful for applying them to improve the quality of frozen foods.
Systems and methods for data quality control and cleansing
Wenzel, Michael; Boettcher, Andrew; Drees, Kirk; Kummer, James
2016-05-31
A method for detecting and cleansing suspect building automation system data is shown and described. The method includes using processing electronics to automatically determine which of a plurality of error detectors and which of a plurality of data cleansers to use with building automation system data. The method further includes using processing electronics to automatically detect errors in the data and cleanse the data using a subset of the error detectors and a subset of the cleansers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rauch, Phillip; Lin, Pei-Jan Paul; Balter, Stephen
2012-05-15
Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of thismore » work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology ''automatic dose rate and image quality'' (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were included in this report, was manufactured within the three year period from 2006 to 2008. Using polymethylmethacrylate (PMMA) plastic to simulate patient attenuation, each angiographic imaging system was evaluated by recording the following parameters: tube potential in units of kilovolts peak (kVp), tube current in units of milliamperes (mA), pulse width (PW) in units of milliseconds (ms), spectral filtration setting, and patient air kerma rate (PAKR) as a function of the attenuator thickness. Data were graphically plotted to reveal the manner in which the ADRIQ control logic responded to changes in object attenuation. There were similarities in the manner in which the ADRIQ control logic operated that allowed the four chosen devices to be divided into two groups, with two of the systems in each group. There were also unique approaches to the ADRIQ control logic that were associated with some of the systems, and these are described in the report. The evaluation revealed relevant information about the testing procedure and also about the manner in which different manufacturers approach the utilization of spectral filtration, pulsed fluoroscopy, and maximum PAKR limitation. This information should be particularly valuable to the clinical medical physicist charged with acceptance testing and performance evaluation of modern angiographic systems.« less
Rauch, Phillip; Lin, Pei-Jan Paul; Balter, Stephen; Fukuda, Atsushi; Goode, Allen; Hartwell, Gary; LaFrance, Terry; Nickoloff, Edward; Shepard, Jeff; Strauss, Keith
2012-05-01
Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology "automatic dose rate and image quality" (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were included in this report, was manufactured within the three year period from 2006 to 2008. Using polymethylmethacrylate (PMMA) plastic to simulate patient attenuation, each angiographic imaging system was evaluated by recording the following parameters: tube potential in units of kilovolts peak (kVp), tube current in units of milliamperes (mA), pulse width (PW) in units of milliseconds (ms), spectral filtration setting, and patient air kerma rate (PAKR) as a function of the attenuator thickness. Data were graphically plotted to reveal the manner in which the ADRIQ control logic responded to changes in object attenuation. There were similarities in the manner in which the ADRIQ control logic operated that allowed the four chosen devices to be divided into two groups, with two of the systems in each group. There were also unique approaches to the ADRIQ control logic that were associated with some of the systems, and these are described in the report. The evaluation revealed relevant information about the testing procedure and also about the manner in which different manufacturers approach the utilization of spectral filtration, pulsed fluoroscopy, and maximum PAKR limitation. This information should be particularly valuable to the clinical medical physicist charged with acceptance testing and performance evaluation of modern angiographic systems.
Use of artificial intelligence in the production of high quality minced meat
NASA Astrophysics Data System (ADS)
Kapovsky, B. R.; Pchelkina, V. A.; Plyasheshnik, P. I.; Dydykin, A. S.; Lazarev, A. A.
2017-09-01
A design for an automatic line for minced meat production according to new production technology based on an innovative meat milling method is proposed. This method allows the necessary degree of raw material comminution at the stage of raw material preparation to be obtained, which leads to production intensification due to the traditional meat mass comminution equipment being unnecessary. To ensure consistent quality of the product obtained, the use of on-line automatic control of the technological process for minced meat production is envisaged. This system has been developed using artificial intelligence methods and technologies. The system is trainable during the operation process, adapts to changes in processed raw material characteristics and to external impacts that affect the system operation, and manufactures meat shavings with minimal dispersion of the typical particle size. The control system includes equipment for express analysis of the chemical composition of the minced meat and its temperature after comminution. In this case, the minced meat production process can be controlled strictly as a function of time, which excludes subjective factors for assessing the degree of finished product readiness. This will allow finished meat products with consistent, targeted high quality to be produced.
Continuous integration and quality control for scientific software
NASA Astrophysics Data System (ADS)
Neidhardt, A.; Ettl, M.; Brisken, W.; Dassing, R.
2013-08-01
Modern software has to be stable, portable, fast and reliable. This is going to be also more and more important for scientific software. But this requires a sophisticated way to inspect, check and evaluate the quality of source code with a suitable, automated infrastructure. A centralized server with a software repository and a version control system is one essential part, to manage the code basis and to control the different development versions. While each project can be compiled separately, the whole code basis can also be compiled with one central “Makefile”. This is used to create automated, nightly builds. Additionally all sources are inspected automatically with static code analysis and inspection tools, which check well-none error situations, memory and resource leaks, performance issues, or style issues. In combination with an automatic documentation generator it is possible to create the developer documentation directly from the code and the inline comments. All reports and generated information are presented as HTML page on a Web server. Because this environment increased the stability and quality of the software of the Geodetic Observatory Wettzell tremendously, it is now also available for scientific communities. One regular customer is already the developer group of the DiFX software correlator project.
Gram staining with an automatic machine.
Felek, S; Arslan, A
1999-01-01
This study was undertaken to develop a new Gram-staining machine controlled by a micro-controller and to investigate the quality of slides that were stained in the machine. The machine was designed and produced by the authors. It uses standard 220 V AC. Staining, washing, and drying periods are controlled by a timer built in the micro-controller. A software was made that contains a certain algorithm and time intervals for the staining mode. One-hundred and forty smears were prepared from Escherichia coli, Staphylococcus aureus, Neisseria sp., blood culture, trypticase soy broth, direct pus and sputum smears for comparison studies. Half of the slides in each group were stained with the machine, the other half by hand and then examined by four different microbiologists. Machine-stained slides had a higher clarity and less debris than the hand-stained slides (p < 0.05). In hand-stained slides, some Gram-positive organisms showed poor Gram-positive staining features (p < 0.05). In conclusion, we suggest that Gram staining with the automatic machine increases the staining quality and helps to decrease the work load in a busy diagnostic laboratory.
Automatic initialization and quality control of large-scale cardiac MRI segmentations.
Albà, Xènia; Lekadir, Karim; Pereañez, Marco; Medrano-Gracia, Pau; Young, Alistair A; Frangi, Alejandro F
2018-01-01
Continuous advances in imaging technologies enable ever more comprehensive phenotyping of human anatomy and physiology. Concomitant reduction of imaging costs has resulted in widespread use of imaging in large clinical trials and population imaging studies. Magnetic Resonance Imaging (MRI), in particular, offers one-stop-shop multidimensional biomarkers of cardiovascular physiology and pathology. A wide range of analysis methods offer sophisticated cardiac image assessment and quantification for clinical and research studies. However, most methods have only been evaluated on relatively small databases often not accessible for open and fair benchmarking. Consequently, published performance indices are not directly comparable across studies and their translation and scalability to large clinical trials or population imaging cohorts is uncertain. Most existing techniques still rely on considerable manual intervention for the initialization and quality control of the segmentation process, becoming prohibitive when dealing with thousands of images. The contributions of this paper are three-fold. First, we propose a fully automatic method for initializing cardiac MRI segmentation, by using image features and random forests regression to predict an initial position of the heart and key anatomical landmarks in an MRI volume. In processing a full imaging database, the technique predicts the optimal corrective displacements and positions in relation to the initial rough intersections of the long and short axis images. Second, we introduce for the first time a quality control measure capable of identifying incorrect cardiac segmentations with no visual assessment. The method uses statistical, pattern and fractal descriptors in a random forest classifier to detect failures to be corrected or removed from subsequent statistical analysis. Finally, we validate these new techniques within a full pipeline for cardiac segmentation applicable to large-scale cardiac MRI databases. The results obtained based on over 1200 cases from the Cardiac Atlas Project show the promise of fully automatic initialization and quality control for population studies. Copyright © 2017 Elsevier B.V. All rights reserved.
Wood, T J; Moore, C S; Stephens, A; Saunderson, J R; Beavis, A W
2015-09-01
Given the increasing use of computed tomography (CT) in the UK over the last 30 years, it is essential to ensure that all imaging protocols are optimised to keep radiation doses as low as reasonably practicable, consistent with the intended clinical task. However, the complexity of modern CT equipment can make this task difficult to achieve in practice. Recent results of local patient dose audits have shown discrepancies between two Philips CT scanners that use the DoseRight 2.0 automatic exposure control (AEC) system in the 'automatic' mode of operation. The use of this system can result in drifting dose and image quality performance over time as it is designed to evolve based on operator technique. The purpose of this study was to develop a practical technique for configuring examination protocols on four CT scanners that use the DoseRight 2.0 AEC system in the 'manual' mode of operation. This method used a uniform phantom to generate reference images which form the basis for how the AEC system calculates exposure factors for any given patient. The results of this study have demonstrated excellent agreement in the configuration of the CT scanners in terms of average patient dose and image quality when using this technique. This work highlights the importance of CT protocol harmonisation in a modern Radiology department to ensure both consistent image quality and radiation dose. Following this study, the average radiation dose for a range of CT examinations has been reduced without any negative impact on clinical image quality.
NASA Technical Reports Server (NTRS)
Hindson, W. S.; Hardy, G. H.; Innis, R. C.
1982-01-01
The essential features of using pitch attitude for glidepath control in conjunction with longitudinal thrust modulation for speed control are described, using a simple linearized model for a powered-lift STOL aircraft operating on the backside of the drag curve and at a fixed setting of propulsive lift. It is shown that an automatic speed-hold system incorporating heave-damping augmentation can allow use of the front-side control technique with satisfactory handling qualities, and the results of previous flight investigations are reviewed. Manual control considerations, as they might be involved following failure of the automatic system, are emphasized. The influence of alternative cockpit controller configurations and flight-director display features were assessed for their effect on the control task, which consisted of a straight-in steep approach flown at constant speed in simulated instrument conditions.
A real time quality control application for animal production by image processing.
Sungur, Cemil; Özkan, Halil
2015-11-01
Standards of hygiene and health are of major importance in food production, and quality control has become obligatory in this field. Thanks to rapidly developing technologies, it is now possible for automatic and safe quality control of food production. For this purpose, image-processing-based quality control systems used in industrial applications are being employed to analyze the quality of food products. In this study, quality control of chicken (Gallus domesticus) eggs was achieved using a real time image-processing technique. In order to execute the quality control processes, a conveying mechanism was used. Eggs passing on a conveyor belt were continuously photographed in real time by cameras located above the belt. The images obtained were processed by various methods and techniques. Using digital instrumentation, the volume of the eggs was measured, broken/cracked eggs were separated and dirty eggs were determined. In accordance with international standards for classifying the quality of eggs, the class of separated eggs was determined through a fuzzy implication model. According to tests carried out on thousands of eggs, a quality control process with an accuracy of 98% was possible. © 2014 Society of Chemical Industry.
Process-based quality for thermal spray via feedback control
NASA Astrophysics Data System (ADS)
Dykhuizen, R. C.; Neiser, R. A.
2006-09-01
Quality control of a thermal spray system manufacturing process is difficult due to the many input variables that need to be controlled. Great care must be taken to ensure that the process remains constant to obtain a consistent quality of the parts. Control is greatly complicated by the fact that measurement of particle velocities and temperatures is a noisy stochastic process. This article illustrates the application of quality control concepts to a wire flame spray process. A central feature of the real-time control system is an automatic feedback control scheme that provides fine adjustments to ensure that uncontrolled variations are accommodated. It is shown how the control vectors can be constructed from simple process maps to independently control particle velocity and temperature. This control scheme is shown to perform well in a real production environment. We also demonstrate that slight variations in the feed wire curvature can greatly influence the process. Finally, the geometry of the spray system and sensor must remain constant for the best reproducibility.
Kim, Sung-Chul; Lee, Hae-Kag; Lee, Yang-Sub; Cho, Jae-Hwan
2015-01-01
We found a way to optimize the image quality and reduce the exposure dose of patients through the proper activity combination of the automatic exposure control system chamber for the dose optimization when examining the pelvic anteroposterior side using the phantom of the human body standard model. We set 7 combinations of the chamber of automatic exposure control system. The effective dose was yielded by measuring five times for each according to the activity combination of the chamber for the dose measurement. Five radiologists with more than five years of experience evaluated the image through picture archiving and communication system using double blind test while classifying the 6 anatomical sites into 3-point level (improper, proper, perfect). When only one central chamber was activated, the effective dose was found to be the highest level, 0.287 mSv; and lowest when only the top left chamber was used, 0.165 mSv. After the subjective evaluation by five panel members on the pelvic image was completed, there was no statistically meaningful difference between the 7 chamber combinations, and all had good image quality. When testing the pelvic anteroposterior side with digital radiography, we were able to reduce the exposure dose of patients using the combination of the top right side of or the top two of the chamber.
NASA Astrophysics Data System (ADS)
Nayar, Priya; Singh, Bhim; Mishra, Sukumar
2017-08-01
An artificial intelligence based control algorithm is used in solving power quality problems of a diesel engine driven synchronous generator with automatic voltage regulator and governor based standalone system. A voltage source converter integrated with a battery energy storage system is employed to mitigate the power quality problems. An adaptive neural network based signed regressor control algorithm is used for the estimation of the fundamental component of load currents for control of a standalone system with load leveling as an integral feature. The developed model of the system performs accurately under varying load conditions and provides good dynamic response to the step changes in loads. The real time performance is achieved using MATLAB along with simulink/simpower system toolboxes and results adhere to an IEEE-519 standard for power quality enhancement.
Phonological Working Memory of Children in Two German Special Schools
ERIC Educational Resources Information Center
Hasselhorn, Marcus; Mahler, Claudia
2007-01-01
In two studies, 10-year-olds from 2 German special schools as well as typically developing children of the same chronological age (CA controls) or the same mental age (MA controls) were compared on several aspects of working memory functions (i.e., size and input quality of the phonological store, speed and automatic activation of the subvocal…
NASA Astrophysics Data System (ADS)
Andriushin, A. V.; Zverkov, V. P.; Kuzishchin, V. F.; Ryzhkov, O. S.; Sabanin, V. R.
2017-11-01
The research and setting results of steam pressure in the main steam collector “Do itself” automatic control system (ACS) with high-speed feedback on steam pressure in the turbine regulating stage are presented. The ACS setup is performed on the simulation model of the controlled object developed for this purpose with load-dependent static and dynamic characteristics and a non-linear control algorithm with pulse control of the turbine main servomotor. A method for tuning nonlinear ACS with a numerical algorithm for multiparametric optimization and a procedure for separate dynamic adjustment of control devices in a two-loop ACS are proposed and implemented. It is shown that the nonlinear ACS adjusted with the proposed method with the regulators constant parameters ensures reliable and high-quality operation without the occurrence of oscillations in the transient processes the operating range of the turbine loads.
Programmable Positioner For Spot Welding
NASA Technical Reports Server (NTRS)
Roden, William A.
1989-01-01
Welding station mechanized by installing preset indexing system and gear drive. Mechanism includes a low-cost, versatile, single-axis motion control and motor drive to provide fully-automatic weld sequencing and spot-to-spot spacing. Welding station relieves operator of some difficult, tedious tasks and increases both productivity and quality of welds. Results in welds of higher quality and greater accuracy, fewer weld defects, and faster welding operation.
Automatic structured grid generation using Gridgen (some restrictions apply)
NASA Technical Reports Server (NTRS)
Chawner, John R.; Steinbrenner, John P.
1995-01-01
The authors have noticed in the recent grid generation literature an emphasis on the automation of structured grid generation. The motivation behind such work is clear; grid generation is easily the most despised task in the grid-analyze-visualize triad of computational analysis (CA). However, because grid generation is closely coupled to both the design and analysis software and because quantitative measures of grid quality are lacking, 'push button' grid generation usually results in a compromise between speed, control, and quality. Overt emphasis on automation obscures the substantive issues of providing users with flexible tools for generating and modifying high quality grids in a design environment. In support of this paper's tongue-in-cheek title, many features of the Gridgen software are described. Gridgen is by no stretch of the imagination an automatic grid generator. Despite this fact, the code does utilize many automation techniques that permit interesting regenerative features.
NASA Astrophysics Data System (ADS)
Sabanin, V. R.; Starostin, A. A.; Repin, A. I.; Popov, A. I.
2017-02-01
The problems of operation effectiveness increase of steam boilers are considered. To maintain the optimum fuel combustion modes, it is proposed to use an extremal controller (EC) determining the value of airflow rate, at which the boiler generating the desired amount of heat will consume a minimum amount of fuel. EC sets the determined value of airflow rate to airflow rate controller (ARC). The test results of numerical simulation dynamic nonlinear model of steam boiler with the connected system of automatic control of load and combustion efficiency using EC are presented. The model is created in the Simulink modeling package of MATLAB software and can be used to optimize the combustion modes. Based on the modeling results, the conclusion was drawn about the possibility in principle of simultaneously boiler load control and optimizing by EC the combustion modes when changing the fuel combustion heat and the boiler characteristics and its operating mode. It is shown that it is possible to automatically control the operation efficiency of steam boilers when using EC without applying the standard flue gas analyzers. The article considers the numerical simulation dynamic model of steam boiler with the schemes of control of fuel consumption and airflow rate, the steam pressure and EC; the purpose of using EC in the scheme with linear controllers and the requirements to the quality of its operation; the results of operation of boiler control schemes without EC with estimation of influence of roughness of thermal mode maps on the nature of static and dynamic connection of the control units of fuel consumption and airflow rate; the phase trajectories and the diagrams of transient processes occurring in the control scheme with EC with stepped changing the fuel quality and boiler characteristics; analysis of modeling results and prospects for using EC in the control schemes of boilers.
1975-12-01
139 APPENDIX A* BASIC CONCEPT OF MILITARY TECHNICAL CONTROL.142 6 APIENDIX Es TEST EQUIPMENI REQUIRED FOR lEASURF.4ENr OF 1AF’AMETE RS...Control ( SATEC ) Automatic Facilities heport Army Automated Quality Monitoring Reporting System (AQMPS) Army Autcmated Technical Control-Semi (ATC-Semi...technical control then beco.. es equipment status monitoring. All the major equipment in a system wculd have internal sensors with properly selected parameters
[Status of cardiorespiratory polysomnographic diagnosis in the sleep laboratory].
Penzel, T
1995-03-01
The different types of sleep related breathing and cardiovascular disorders are well known and defined nowadays. Thereby it is possible to present a configuration by which a cardiorespiratory sleep laboratory is enabled to perform a complete differential diagnosis. This configuration consists of the function sleep with EEG, EOG and EMG, the function respiration with respiratory effort, respiratory flow and oxygen saturation, and the cardiovascular function with ECG and blood pressure if indicated. Continuous monitoring by videocamera and a patient call system with a technician present during the entire recording time must be assured. Recording and evaluation of all signals can be done with chart polygraphs or with computer systems if they provide a high-resolution graphic monitor. Automatic sleep analysis systems support evaluation of polysomnograms. But automatic analysis of sleep stages as well as automatic analysis of respiratory disorders needs visual counterchecking before results can be accepted. On the basis of today's knowledge recommendation for the setting of a sleep laboratory were set and new sleep labs are controlled on a voluntary basis by a commission of the German society for sleep research and sleep medicine. This first step of quality control is introduced to establish a procedure to keep quality of diagnosis and treatment on a high level in this medical specialty.
A Laser-Based Measuring System for Online Quality Control of Car Engine Block.
Li, Xing-Qiang; Wang, Zhong; Fu, Lu-Hua
2016-11-08
For online quality control of car engine production, pneumatic measurement instrument plays an unshakeable role in measuring diameters inside engine block because of its portability and high-accuracy. To the limitation of its measuring principle, however, the working space between the pneumatic device and measured surface is too small to require manual operation. This lowers the measuring efficiency and becomes an obstacle to perform automatic measurement. In this article, a high-speed, automatic measuring system is proposed to take the place of pneumatic devices by using a laser-based measuring unit. The measuring unit is considered as a set of several measuring modules, where each of them acts like a single bore gauge and is made of four laser triangulation sensors (LTSs), which are installed on different positions and in opposite directions. The spatial relationship among these LTSs was calibrated before measurements. Sampling points from measured shaft holes can be collected by the measuring unit. A unified mathematical model was established for both calibration and measurement. Based on the established model, the relative pose between the measuring unit and measured workpiece does not impact the measuring accuracy. This frees the measuring unit from accurate positioning or adjustment, and makes it possible to realize fast and automatic measurement. The proposed system and method were finally validated by experiments.
Sobol, Wlad T
2002-01-01
A simple kinetic model that describes the time evolution of the chemical concentration of an arbitrary compound within the tank of an automatic film processor is presented. It provides insights into the kinetics of chemistry concentration inside the processor's tank; the results facilitate the tasks of processor tuning and quality control (QC). The model has successfully been used in several troubleshooting sessions of low-volume mammography processors for which maintaining consistent QC tracking was difficult due to fluctuations of bromide levels in the developer tank.
NASA Astrophysics Data System (ADS)
Chen, Xiangqun; Huang, Rui; Shen, Liman; chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Liu, Mouhai; Xu, Renheng
2018-03-01
In this paper, the semi-active RFID watt-hour meter is applied to automatic test lines and intelligent warehouse management, from the transmission system, test system and auxiliary system, monitoring system, realize the scheduling of watt-hour meter, binding, control and data exchange, and other functions, make its more accurate positioning, high efficiency of management, update the data quickly, all the information at a glance. Effectively improve the quality, efficiency and automation of verification, and realize more efficient data management and warehouse management.
NASA Astrophysics Data System (ADS)
Lukyanov, A. A.; Grigoriev, S. N.; Bobrovskij, I. N.; Melnikov, P. A.; Bobrovskij, N. M.
2017-05-01
With regard to the complexity of the new technology and increase its reliability requirements laboriousness of control operations in industrial quality control systems increases significantly. The importance of quality management control due to the fact that its promotes the correct use of production conditions, the relevant requirements are required. Digital image processing allows to reach a new technological level of production (new technological way). The most complicated automated interpretation of information is the basis for decision-making in the management of production processes. In the case of surface analysis of tools used for processing with the using of metalworking fluids (MWF) it is more complicated. The authors suggest new algorithm for optical inspection of the wear of the cylinder tool for burnishing, which used in surface plastic deformation without using of MWF. The main advantage of proposed algorithm is the possibility of automatic recognition of images of burnisher tool with the subsequent allocation of its boundaries, finding a working surface and automatically allocating the defects and wear area. Software that implements the algorithm was developed by the authors in Matlab programming environment, but can be implemented using other programming languages.
Automatic film processors' quality control test in Greek military hospitals.
Lymberis, C; Efstathopoulos, E P; Manetou, A; Poudridis, G
1993-04-01
The two major military radiology installations (Athens, Greece) using a total of 15 automatic film processors were assessed using the 21-step-wedge method. The results of quality control in all these processors are presented. The parameters measured under actual working conditions were base and fog, contrast and speed. Base and fog as well as speed displayed large variations with average values generally higher than acceptable, whilst contrast displayed greater stability. Developer temperature was measured daily during the test and was found to be outside the film manufacturers' recommended limits in nine of the 15 processors. In only one processor did film passing time vary on an every day basis and this was due to maloperation. Developer pH test was not part of the daily monitoring service being performed every 5 days for each film processor and found to be in the range 9-12; 10 of the 15 processors presented pH values outside the limits specified by the film manufacturers.
Automatic detection of DNA double strand breaks after irradiation using an γH2AX assay.
Hohmann, Tim; Kessler, Jacqueline; Grabiec, Urszula; Bache, Matthias; Vordermark, Dyrk; Dehghani, Faramarz
2018-05-01
Radiation therapy belongs to the most common approaches for cancer therapy leading amongst others to DNA damage like double strand breaks (DSB). DSB can be used as a marker for the effect of radiation on cells. For visualization and assessing the extent of DNA damage the γH2AX foci assay is frequently used. The analysis of the γH2AX foci assay remains complicated as the number of γH2AX foci has to be counted. The quantification is mostly done manually, being time consuming and leading to person-dependent variations. Therefore, we present a method to automatically analyze the number of foci inside nuclei, facilitating and quickening the analysis of DSBs with high reliability in fluorescent images. First nuclei were detected in fluorescent images. Afterwards, the nuclei were analyzed independently from each other with a local thresholding algorithm. This approach allowed accounting for different levels of noise and detection of the foci inside the respective nucleus, using Hough transformation searching for circles. The presented algorithm was able to correctly classify most foci in cases of "high" and "average" image quality (sensitivity>0.8) with a low rate of false positive detections (positive predictive value (PPV)>0.98). In cases of "low" image quality the approach had a decreased sensitivity (0.7-0.9), depending on the manual control counter. The PPV remained high (PPV>0.91). Compared to other automatic approaches the presented algorithm had a higher sensitivity and PPV. The used automatic foci detection algorithm was capable of detecting foci with high sensitivity and PPV. Thus it can be used for automatic analysis of images of varying quality.
Water quality monitor. [spacecraft potable water
NASA Technical Reports Server (NTRS)
West, S.; Crisos, J.; Baxter, W.
1979-01-01
The preprototype water quality monitor (WQM) subsystem was designed based on a breadboard monitor for pH, specific conductance, and total organic carbon (TOC). The breadboard equipment demonstrated the feasibility of continuous on-line analysis of potable water for a spacecraft. The WQM subsystem incorporated these breadboard features and, in addition, measures ammonia and includes a failure detection system. The sample, reagent, and standard solutions are delivered to the WQM sensing manifold where chemical operations and measurements are performed using flow through sensors for conductance, pH, TOC, and NH3. Fault monitoring flow detection is also accomplished in this manifold assembly. The WQM is designed to operate automatically using a hardwired electronic controller. In addition, automatic shutdown is incorporated which is keyed to four flow sensors strategically located within the fluid system.
Liu, Ping; Li, Guodong; Liu, Xinggao; Xiao, Long; Wang, Yalin; Yang, Chunhua; Gui, Weihua
2018-02-01
High quality control method is essential for the implementation of aircraft autopilot system. An optimal control problem model considering the safe aerodynamic envelop is therefore established to improve the control quality of aircraft flight level tracking. A novel non-uniform control vector parameterization (CVP) method with time grid refinement is then proposed for solving the optimal control problem. By introducing the Hilbert-Huang transform (HHT) analysis, an efficient time grid refinement approach is presented and an adaptive time grid is automatically obtained. With this refinement, the proposed method needs fewer optimization parameters to achieve better control quality when compared with uniform refinement CVP method, whereas the computational cost is lower. Two well-known flight level altitude tracking problems and one minimum time cost problem are tested as illustrations and the uniform refinement control vector parameterization method is adopted as the comparative base. Numerical results show that the proposed method achieves better performances in terms of optimization accuracy and computation cost; meanwhile, the control quality is efficiently improved. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
Spray deposition inside multiple-row nursery trees with a laser-guided sprayer
USDA-ARS?s Scientific Manuscript database
Multiple-row container-grown trees require specially designed sprayers to achieve efficient spray delivery quality. A five-port air-assisted sprayer with both automatic and manual control modes was developed to discharge adequate spray deposition inside multiple-row tree plants. The sprayer resulted...
Design and pilot evaluation of the RAH-66 Comanche Core AFCS
NASA Technical Reports Server (NTRS)
Fogler, Donald L., Jr.; Keller, James F.
1993-01-01
This paper addresses the design and pilot evaluation of the Core Automatic Flight Control System (AFCS) for the Reconnaissance/Attack Helicopter (RAH-66) Comanche. During the period from November 1991 through February 1992, the RAH-66 Comanche control laws were evaluated through a structured pilot acceptance test using a motion base simulator. Design requirements, descriptions of the control law design, and handling qualities data collected from ADS-33 maneuvers are presented.
Handling qualities related to stall/spin accidents of supersonic fighter aircraft
NASA Technical Reports Server (NTRS)
Anderson, S. B.
1984-01-01
This paper reviews the handling qualities which influence the high angle of attack (AOA) behavior of supersonic fighter aircraft in order to obtain a clearer understanding of the causes of stall/spin accidents. The results show that, because modern fighters suffer more serious consequences when control is lost, good handling qualities are essential for safe operation at high AOA. Relaxed static stability used on some fighter aircraft can result in control problems at high AOA owing to inertia coupling and the difficulty of a recovery from a deep stall. Indications are that the use of departure/spin resistance and an automatic spin prevention system will greatly improve the safety record for modern supersonic fighters.
Motto: We work for people and environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barcik, M.
1995-12-31
This target has been under Danfoss realization for over 60 years, both in Denmark and all over the world. The operational range of the enterprise: is very wide. Danfoss manufactures a large assortment of products, starting from heat automatic control systems, through heat metering devices, industrial and refrigeration automatic control, compressors, flow meters, frequency converters, control systems, and monitoring. The four mainstays of the business activity are based on: high quality products; advanced manufacturing technology; care of the environment, and engagement of the staff. Since 1992 Danfoss has been manufacturing heat radiator thermostats in Poland. A unique solution - namelymore » the use of a gas thermostatic head secures the highest energy savings and operational reliability. In 1993, Danfoss as the sixth company in Poland and the first in its business field, gained a ISO 9002 certificate.« less
Yoon, Jun-Hee; Kim, Thomas W; Mendez, Pedro; Jablons, David M; Kim, Il-Jin
2017-01-01
The development of next-generation sequencing (NGS) technology allows to sequence whole exomes or genome. However, data analysis is still the biggest bottleneck for its wide implementation. Most laboratories still depend on manual procedures for data handling and analyses, which translates into a delay and decreased efficiency in the delivery of NGS results to doctors and patients. Thus, there is high demand for developing an automatic and an easy-to-use NGS data analyses system. We developed comprehensive, automatic genetic analyses controller named Mobile Genome Express (MGE) that works in smartphones or other mobile devices. MGE can handle all the steps for genetic analyses, such as: sample information submission, sequencing run quality check from the sequencer, secured data transfer and results review. We sequenced an Actrometrix control DNA containing multiple proven human mutations using a targeted sequencing panel, and the whole analysis was managed by MGE, and its data reviewing program called ELECTRO. All steps were processed automatically except for the final sequencing review procedure with ELECTRO to confirm mutations. The data analysis process was completed within several hours. We confirmed the mutations that we have identified were consistent with our previous results obtained by using multi-step, manual pipelines.
Civil (French/US) certification of the Coast Guard's HH-65A Dauphin
NASA Technical Reports Server (NTRS)
Hart, J. C.; Besse, J. M.; Mcelreath, K. W.
1982-01-01
Certification programs with particular emphasis on handling qualities requirements are described. A dynamic simulator was designed and constructed to support and verify the dynamic aspects of the avionics system, particularly the Automatic Flight Control System (AFCS). The role of the Dynamic Simulator is discussed.
NASA Astrophysics Data System (ADS)
Park, Sangwook; Lee, Young-Ran; Hwang, Yoola; Javier Santiago Noguero Galilea
2009-12-01
This paper describes the Flight Dynamics Automation (FDA) system for COMS Flight Dynamics System (FDS) and its test result in terms of the performance of the automation jobs. FDA controls the flight dynamics functions such as orbit determination, orbit prediction, event prediction, and fuel accounting. The designed FDA is independent from the specific characteristics which are defined by spacecraft manufacturer or specific satellite missions. Therefore, FDA could easily links its autonomous job control functions to any satellite mission control system with some interface modification. By adding autonomous system along with flight dynamics system, it decreases the operator’s tedious and repeated jobs but increase the usability and reliability of the system. Therefore, FDA is used to improve the completeness of whole mission control system’s quality. The FDA is applied to the real flight dynamics system of a geostationary satellite, COMS and the experimental test is performed. The experimental result shows the stability and reliability of the mission control operations through the automatic job control.
Novel low-cost vision-sensing technology with controllable of exposal time for welding
NASA Astrophysics Data System (ADS)
Zhang, Wenzeng; Wang, Bin; Chen, Nian; Cao, Yipeng
2005-02-01
In the process of robot Welding, position of welding seam and welding pool shape is detected by CCD camera for quality control and seam tracking in real-time. It is difficult to always get a clear welding image in some welding methods, such as TIG welding. A novel idea that the exposal time of CCD camera is automatically controlled by arc voltage or arc luminance is proposed to get clear welding image. A set of special device and circuits are added to a common industrial CCD camera in order to flexibly control the CCD to start or close exposal by control of the internal clearing signal of the accumulated charge. Two special vision sensors according to the idea are developed. Their exposal grabbing can be triggered respectively by the arc voltage and the variety of the arc luminance. Two prototypes have been designed and manufactured. Experiments show that they can stably grab clear welding images at appointed moment, which is a basic for the feedback control of automatic welding.
NASA Astrophysics Data System (ADS)
Zhilenkov, A. A.; Efremov, A. A.
2017-02-01
A possibility of quality improvement of stabilization of rotation frequency of the gas-diesels used as prime mover of generator set in the multigenerator units working for abruptly variable load of large power is considered. An evaluation is made on the condition of fuzzy controller use developed and described by the authors in a number of articles. An evaluation has shown that theoretically, the revolution range of a gas-diesel engine may be reduced 25-30 times in case of optimal settings of the controller in the whole power range. The results of modelling showing a considerable quality improvement of transient processes in the investigated system during a sharp change of loading are presented in this article.
Chien, S H; Hsieh, M K; Li, H; Monnell, J; Dzombak, D; Vidic, R
2012-02-01
Pilot-scale cooling towers can be used to evaluate corrosion, scaling, and biofouling control strategies when using particular cooling system makeup water and particular operating conditions. To study the potential for using a number of different impaired waters as makeup water, a pilot-scale system capable of generating 27,000 kJ∕h heat load and maintaining recirculating water flow with a Reynolds number of 1.92 × 10(4) was designed to study these critical processes under conditions that are similar to full-scale systems. The pilot-scale cooling tower was equipped with an automatic makeup water control system, automatic blowdown control system, semi-automatic biocide feeding system, and corrosion, scaling, and biofouling monitoring systems. Observed operational data revealed that the major operating parameters, including temperature change (6.6 °C), cycles of concentration (N = 4.6), water flow velocity (0.66 m∕s), and air mass velocity (3660 kg∕h m(2)), were controlled quite well for an extended period of time (up to 2 months). Overall, the performance of the pilot-scale cooling towers using treated municipal wastewater was shown to be suitable to study critical processes (corrosion, scaling, biofouling) and evaluate cooling water management strategies for makeup waters of complex quality.
A Laser-Based Measuring System for Online Quality Control of Car Engine Block
Li, Xing-Qiang; Wang, Zhong; Fu, Lu-Hua
2016-01-01
For online quality control of car engine production, pneumatic measurement instrument plays an unshakeable role in measuring diameters inside engine block because of its portability and high-accuracy. To the limitation of its measuring principle, however, the working space between the pneumatic device and measured surface is too small to require manual operation. This lowers the measuring efficiency and becomes an obstacle to perform automatic measurement. In this article, a high-speed, automatic measuring system is proposed to take the place of pneumatic devices by using a laser-based measuring unit. The measuring unit is considered as a set of several measuring modules, where each of them acts like a single bore gauge and is made of four laser triangulation sensors (LTSs), which are installed on different positions and in opposite directions. The spatial relationship among these LTSs was calibrated before measurements. Sampling points from measured shaft holes can be collected by the measuring unit. A unified mathematical model was established for both calibration and measurement. Based on the established model, the relative pose between the measuring unit and measured workpiece does not impact the measuring accuracy. This frees the measuring unit from accurate positioning or adjustment, and makes it possible to realize fast and automatic measurement. The proposed system and method were finally validated by experiments. PMID:27834839
East Europe Report, Economic and Industrial Affairs, No. 2431
1983-08-03
of automatic control systems in this branch of transportation, as well as in reservations and ticket sales. An agreement on research is...cooperative, the labor is organized in common and the remuneration is done in relation to the quantity and quality of the labor performed, the output...use in the state supply; f) The rational and efficient exploitation of the irrigation facilities, the drainage facilities and those for control of
Evaluation Of Rotation Frequency Gas-Diesel Engines When Using Automatic Control System
NASA Astrophysics Data System (ADS)
Zhilenkov, A.; Efremov, A.
2017-01-01
A possibility of quality improvement of stabilization of rotation frequency of the gas-diesels used as prime mover of generator set in the multigenerator units working for abruptly variable load of large power is considered. An evaluation is made on condition of fuzzy controller use developed and described by the authors in a number of articles. An evaluation has shown that theoretically, the revolution range of gas-diesel engine may be reduced at 25-30 times at optimal settings of the controller in all the power range. The results of modeling showing a considerable quality improvement of transient processes in the investigated system at a sharp change of loading are presented in this article.
46 CFR 52.01-10 - Automatic controls.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Automatic controls. 52.01-10 Section 52.01-10 Shipping... Requirements § 52.01-10 Automatic controls. (a) Each main boiler must meet the special requirements for automatic safety controls in § 62.35-20(a)(1) of this chapter. (b) Each automatically controlled auxiliary...
46 CFR 52.01-10 - Automatic controls.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Automatic controls. 52.01-10 Section 52.01-10 Shipping... Requirements § 52.01-10 Automatic controls. (a) Each main boiler must meet the special requirements for automatic safety controls in § 62.35-20(a)(1) of this chapter. (b) Each automatically controlled auxiliary...
46 CFR 52.01-10 - Automatic controls.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Automatic controls. 52.01-10 Section 52.01-10 Shipping... Requirements § 52.01-10 Automatic controls. (a) Each main boiler must meet the special requirements for automatic safety controls in § 62.35-20(a)(1) of this chapter. (b) Each automatically controlled auxiliary...
46 CFR 52.01-10 - Automatic controls.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Automatic controls. 52.01-10 Section 52.01-10 Shipping... Requirements § 52.01-10 Automatic controls. (a) Each main boiler must meet the special requirements for automatic safety controls in § 62.35-20(a)(1) of this chapter. (b) Each automatically controlled auxiliary...
46 CFR 52.01-10 - Automatic controls.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Automatic controls. 52.01-10 Section 52.01-10 Shipping... Requirements § 52.01-10 Automatic controls. (a) Each main boiler must meet the special requirements for automatic safety controls in § 62.35-20(a)(1) of this chapter. (b) Each automatically controlled auxiliary...
Flight Control Development for the ARH-70 Armed Reconnaissance Helicopter Program
NASA Technical Reports Server (NTRS)
Christensen, Kevin T.; Campbell, Kip G.; Griffith, Carl D.; Ivler, Christina M.; Tischler, Mark B.; Harding, Jeffrey W.
2008-01-01
In July 2005, Bell Helicopter won the U.S. Army's Armed Reconnaissance Helicopter competition to produce a replacement for the OH-58 Kiowa Warrior capable of performing the armed reconnaissance mission. To meet the U.S. Army requirement that the ARH-70A have Level 1 handling qualities for the scout rotorcraft mission task elements defined by ADS-33E-PRF, Bell equipped the aircraft with their generic automatic flight control system (AFCS). Under the constraints of the tight ARH-70A schedule, the development team used modem parameter identification and control law optimization techniques to optimize the AFCS gains to simultaneously meet multiple handling qualities design criteria. This paper will show how linear modeling, control law optimization, and simulation have been used to produce a Level 1 scout rotorcraft for the U.S. Army, while minimizing the amount of flight testing required for AFCS development and handling qualities evaluation of the ARH-70A.
30 CFR 77.314 - Automatic temperature control instruments.
Code of Federal Regulations, 2011 CFR
2011-07-01
... UNDERGROUND COAL MINES Thermal Dryers § 77.314 Automatic temperature control instruments. (a) Automatic temperature control instruments for thermal dryer system shall be of the recording type. (b) Automatic... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic temperature control instruments. 77...
30 CFR 77.314 - Automatic temperature control instruments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... UNDERGROUND COAL MINES Thermal Dryers § 77.314 Automatic temperature control instruments. (a) Automatic temperature control instruments for thermal dryer system shall be of the recording type. (b) Automatic... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic temperature control instruments. 77...
30 CFR 77.314 - Automatic temperature control instruments.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic temperature control instruments. 77... UNDERGROUND COAL MINES Thermal Dryers § 77.314 Automatic temperature control instruments. (a) Automatic temperature control instruments for thermal dryer system shall be of the recording type. (b) Automatic...
30 CFR 77.314 - Automatic temperature control instruments.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic temperature control instruments. 77... UNDERGROUND COAL MINES Thermal Dryers § 77.314 Automatic temperature control instruments. (a) Automatic temperature control instruments for thermal dryer system shall be of the recording type. (b) Automatic...
30 CFR 77.314 - Automatic temperature control instruments.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic temperature control instruments. 77... UNDERGROUND COAL MINES Thermal Dryers § 77.314 Automatic temperature control instruments. (a) Automatic temperature control instruments for thermal dryer system shall be of the recording type. (b) Automatic...
Söderberg, Marcus
2016-06-01
Today, computed tomography (CT) systems routinely use automatic exposure control (AEC), which modulates the tube current. However, for optimal use, there are several aspects of an AEC system that need to be considered. The purpose of this study was to provide an overview of the Siemens CARE Dose 4D AEC system, discuss practical tips and demonstrate potential pitfalls. Two adult anthropomorphic phantoms were examined using two different Siemens CT systems. When optimising the CT radiation dose and image quality, the projection angle of the localiser, patient centring, protocol selection, scanning direction and the use of protective devices requires special attention. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
USDA-ARS?s Scientific Manuscript database
Among the most promising tools available for determining precise N requirements are soil mineral N tests. Field tests that evaluated this practice, however, have been conducted under only limited weather and soil conditions. Previous research has shown that using agricultural systems models such as ...
Effect of Personnel Quality on the Performance of Patriot Air Defense System Operators,
1992-01-01
comparable officer-enlisted pair operates a similar facil- ity that controls the activities of three to six batteries. At battery level, the enlisted...them in relation to prescribed rules of engagement. 2Automatic in this context means that the computer identifies an aircraft as friendly, hostile, or
Implementation guide for turbidity threshold sampling: principles, procedures, and analysis
Jack Lewis; Rand Eads
2009-01-01
Turbidity Threshold Sampling uses real-time turbidity and river stage information to automatically collect water quality samples for estimating suspended sediment loads. The system uses a programmable data logger in conjunction with a stage measurement device, a turbidity sensor, and a pumping sampler. Specialized software enables the user to control the sampling...
Automatic control of electric thermal storage (heat) under real-time pricing. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daryanian, B.; Tabors, R.D.; Bohn, R.E.
1995-01-01
Real-time pricing (RTP) can be used by electric utilities as a control signal for responsive demand-side management (DSM) programs. Electric thermal storage (ETS) systems in buildings provide the inherent flexibility needed to take advantage of variations in prices. Under RTP, optimal performance for ETS operations is achieved under market conditions where reductions in customers` costs coincide with the lowering of the cost of service for electric utilities. The RTP signal conveys the time-varying actual marginal cost of the electric service to customers. The RTP rate is a combination of various cost components, including marginal generation fuel and maintenance costs, marginalmore » costs of transmission and distribution losses, and marginal quality of supply and transmission costs. This report describes the results of an experiment in automatic control of heat storage systems under RTP during the winter seasons of 1989--90 and 1990--91.« less
Handling Qualities of a Large Civil Tiltrotor in Hover using Translational Rate Command
NASA Technical Reports Server (NTRS)
Malpica, Carlos A.; Theodore, Colin R.; Lawrence, Ben; Lindsey, James; Blanken, Chris
2012-01-01
A Translational Rate Command (TRC) control law has been developed to enable low speed maneuvering of a large civil tiltrotor with minimal pitch changes by means of automatic nacelle angle deflections for longitudinal velocity control. The nacelle actuator bandwidth required to achieve Level 1 handling qualities in hover and the feasibility of additional longitudinal cyclic control to augment low bandwidth nacelle actuation were investigated. A frequency-domain handling qualities criterion characterizing TRC response in terms of bandwidth and phase delay was proposed and validated against a piloted simulation conducted on the NASA-Ames Vertical Motion Simulator. Seven experimental test pilots completed evaluations in the ADS-33E-PRF Hover Mission Task Element (MTE) for a matrix of nacelle actuator bandwidths, equivalent rise times and control response sensitivities, and longitudinal cyclic control allocations. Evaluated against this task, longitudinal phase delay shows the Level 1 boundary is around 0.4 0.5 s. Accordingly, Level 1 handling qualities were achieved either with a nacelle actuator bandwidth greater than 4 rad/s, or by employing longitudinal cyclic control to augment low bandwidth nacelle actuation.
Perceptual tools for quality-aware video networks
NASA Astrophysics Data System (ADS)
Bovik, A. C.
2014-01-01
Monitoring and controlling the quality of the viewing experience of videos transmitted over increasingly congested networks (especially wireless networks) is a pressing problem owing to rapid advances in video-centric mobile communication and display devices that are straining the capacity of the network infrastructure. New developments in automatic perceptual video quality models offer tools that have the potential to be used to perceptually optimize wireless video, leading to more efficient video data delivery and better received quality. In this talk I will review key perceptual principles that are, or could be used to create effective video quality prediction models, and leading quality prediction models that utilize these principles. The goal is to be able to monitor and perceptually optimize video networks by making them "quality-aware."
Schönherr, Sebastian; Neuner, Mathias; Forer, Lukas; Specht, Günther; Kloss-Brandstätter, Anita; Kronenberg, Florian; Coassin, Stefan
2013-01-01
Single nucleotide polymorphisms (SNPs) play a prominent role in modern genetics. Current genotyping technologies such as Sequenom iPLEX, ABI TaqMan and KBioscience KASPar made the genotyping of huge SNP sets in large populations straightforward and allow the generation of hundreds of thousands of genotypes even in medium sized labs. While data generation is straightforward, the subsequent data conversion, storage and quality control steps are time-consuming, error-prone and require extensive bioinformatic support. In order to ease this tedious process, we developed SNPflow. SNPflow is a lightweight, intuitive and easily deployable application, which processes genotype data from Sequenom MassARRAY (iPLEX) and ABI 7900HT (TaqMan, KASPar) systems and is extendible to other genotyping methods as well. SNPflow automatically converts the raw output files to ready-to-use genotype lists, calculates all standard quality control values such as call rate, expected and real amount of replicates, minor allele frequency, absolute number of discordant replicates, discordance rate and the p-value of the HWE test, checks the plausibility of the observed genotype frequencies by comparing them to HapMap/1000-Genomes, provides a module for the processing of SNPs, which allow sex determination for DNA quality control purposes and, finally, stores all data in a relational database. SNPflow runs on all common operating systems and comes as both stand-alone version and multi-user version for laboratory-wide use. The software, a user manual, screenshots and a screencast illustrating the main features are available at http://genepi-snpflow.i-med.ac.at. PMID:23527209
Video control system for a drilling in furniture workpiece
NASA Astrophysics Data System (ADS)
Khmelev, V. L.; Satarov, R. N.; Zavyalova, K. V.
2018-05-01
During last 5 years, Russian industry has being starting to be a robotic, therefore scientific groups got new tasks. One of new tasks is machine vision systems, which should solve problem of automatic quality control. This type of systems has a cost of several thousand dollars each. The price is impossible for regional small business. In this article, we describe principle and algorithm of cheap video control system, which one uses web-cameras and notebook or desktop computer as a computing unit.
Intelligent Control Approaches for Aircraft Applications
NASA Technical Reports Server (NTRS)
Gundy-Burlet, Karen; KrishnaKumar, K.; Soloway, Don; Kaneshige, John; Clancy, Daniel (Technical Monitor)
2001-01-01
This paper presents an overview of various intelligent control technologies currently being developed and studied under the Intelligent Flight Control (IFC) program at the NASA Ames Research Center. The main objective of the intelligent flight control program is to develop the next generation of flight controllers for the purpose of automatically compensating for a broad spectrum of damaged or malfunctioning aircraft components and to reduce control law development cost and time. The approaches being examined include: (a) direct adaptive dynamic inverse controller and (b) an adaptive critic-based dynamic inverse controller. These approaches can utilize, but do not require, fault detection and isolation information. Piloted simulation studies are performed to examine if the intelligent flight control techniques adequately: 1) Match flying qualities of modern fly-by-wire flight controllers under nominal conditions; 2) Improve performance under failure conditions when sufficient control authority is available; and 3) Achieve consistent handling qualities across the flight envelope and for different aircraft configurations. Results obtained so far demonstrate the potential for improving handling qualities and significantly increasing survivability rates under various simulated failure conditions.
Parametric diagnosis of the adaptive gas path in the automatic control system of the aircraft engine
NASA Astrophysics Data System (ADS)
Kuznetsova, T. A.
2017-01-01
The paper dwells on the adaptive multimode mathematical model of the gas-turbine aircraft engine (GTE) embedded in the automatic control system (ACS). The mathematical model is based on the throttle performances, and is characterized by high accuracy of engine parameters identification in stationary and dynamic modes. The proposed on-board engine model is the state space linearized low-level simulation. The engine health is identified by the influence of the coefficient matrix. The influence coefficient is determined by the GTE high-level mathematical model based on measurements of gas-dynamic parameters. In the automatic control algorithm, the sum of squares of the deviation between the parameters of the mathematical model and real GTE is minimized. The proposed mathematical model is effectively used for gas path defects detecting in on-line GTE health monitoring. The accuracy of the on-board mathematical model embedded in ACS determines the quality of adaptive control and reliability of the engine. To improve the accuracy of identification solutions and sustainability provision, the numerical method of Monte Carlo was used. The parametric diagnostic algorithm based on the LPτ - sequence was developed and tested. Analysis of the results suggests that the application of the developed algorithms allows achieving higher identification accuracy and reliability than similar models used in practice.
SU-E-T-362: Automatic Catheter Reconstruction of Flap Applicators in HDR Surface Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buzurovic, I; Devlin, P; Hansen, J
2014-06-01
Purpose: Catheter reconstruction is crucial for the accurate delivery of radiation dose in HDR brachytherapy. The process becomes complicated and time-consuming for large superficial clinical targets with a complex topology. A novel method for the automatic catheter reconstruction of flap applicators is proposed in this study. Methods: We have developed a program package capable of image manipulation, using C++class libraries of The-Visualization-Toolkit(VTK) software system. The workflow for automatic catheter reconstruction is: a)an anchor point is placed in 3D or in the axial view of the first slice at the tip of the first, last and middle points for the curvedmore » surface; b)similar points are placed on the last slice of the image set; c)the surface detection algorithm automatically registers the points to the images and applies the surface reconstruction filter; d)then a structured grid surface is generated through the center of the treatment catheters placed at a distance of 5mm from the patient's skin. As a result, a mesh-style plane is generated with the reconstructed catheters placed 10mm apart. To demonstrate automatic catheter reconstruction, we used CT images of patients diagnosed with cutaneous T-cell-lymphoma and imaged with Freiburg-Flap-Applicators (Nucletron™-Elekta, Netherlands). The coordinates for each catheter were generated and compared to the control points selected during the manual reconstruction for 16catheters and 368control point Results: The variation of the catheter tip positions between the automatically and manually reconstructed catheters was 0.17mm(SD=0.23mm). The position difference between the manually selected catheter control points and the corresponding points obtained automatically was 0.17mm in the x-direction (SD=0.23mm), 0.13mm in the y-direction (SD=0.22mm), and 0.14mm in the z-direction (SD=0.24mm). Conclusion: This study shows the feasibility of the automatic catheter reconstruction of flap applicators with a high level of positioning accuracy. Implementation of this technique has potential to decrease the planning time and may improve overall quality in superficial brachytherapy.« less
Chomiak, Taylor; Watts, Alexander; Meyer, Nicole; Pereira, Fernando V; Hu, Bin
2017-02-01
Deficits in motor movement automaticity in Parkinson's disease (PD), especially during multitasking, are early and consistent hallmarks of cognitive function decline, which increases fall risk and reduces quality of life. This study aimed to test the feasibility and potential efficacy of a wearable sensor-enabled technological platform designed for an in-home music-contingent stepping-in-place (SIP) training program to improve step automaticity during dual-tasking (DT). This was a 4-week prospective intervention pilot study. The intervention uses a sensor system and algorithm that runs off the iPod Touch which calculates step height (SH) in real-time. These measurements were then used to trigger auditory (treatment group, music; control group, radio podcast) playback in real-time through wireless headphones upon maintenance of repeated large amplitude stepping. With small steps or shuffling, auditory playback stops, thus allowing participants to use anticipatory motor control to regain positive feedback. Eleven participants were recruited from an ongoing trial (Trial Number: ISRCTN06023392). Fear of falling (FES-I), general cognitive functioning (MoCA), self-reported freezing of gait (FOG-Q), and DT step automaticity were evaluated. While we found no significant effect of training on FES-I, MoCA, or FOG-Q, we did observe a significant group (music vs podcast) by training interaction in DT step automaticity (P<0.01). Wearable device technology can be used to enable musically-contingent SIP training to increase motor automaticity for people living with PD. The training approach described here can be implemented at home to meet the growing demand for self-management of symptoms by patients.
Harper, Katharine D; Li, Shidong; Jennings, Rachel; Amer, Kamil M; Haydel, Christopher; Ali, Sayed
2018-01-01
Technologic advances have reduced medical radiation exposure while maintaining image quality. The purpose of this study was to determine the effects of the presence of total hip arthroplasty implants, compared with native hips, on radiation exposure of the most radiosensitive organs when manual and automatic exposure control settings are used. Detection probes were placed at six locations (stomach, sigmoid colon, right pelvic wall, left pelvic wall, pubic symphysis, and anterior pubic skin) in a cadaver. Radiographs were obtained with the use of manual and automatic exposure control protocols, with exposures recorded. A total hip arthroplasty implant was placed in the cadaver, probe positioning was confirmed, and the radiographs were repeated, with exposure values recorded. The control probe placed at the stomach had values ranging from 0.00 mSv to 0.01 mSv in protocols with and without implants. With the manual protocol, exposures in the pelvis ranged from 0.36 mSv to 2.74 mSv in the native hip and from 0.33 mSv to 2.24 mSv after implant placement. The increases in exposure after implant placement, represented as relative risk, were as follows: stomach, 1.000; pubic symphysis, 0.818; left pelvic wall, 1.381; sigmoid colon, 1.550; right pelvic wall, 0.917; and anterior pubic skin, 1.015. With automatic exposure control, exposures in the pelvis ranged from 0.07 mSv to 0.89 mSv in the native hip and from 0.21 mSv to 1.15 mSv after implant placement. With automatic exposure control, the increases in exposure after implant placement, represented as relative risk, were as follows: stomach, 1.000; pubic symphysis, 1.292; left pelvic wall, 1.476; sigmoid colon, 2.182; right pelvic wall, 3.000; and anterior pubic skin, 1.378. The amount of radiation to which patients are exposed as a result of medical procedures or imaging, and whether exposure is associated with an increased risk of malignant transformation, are the subject of ongoing debate. We found that after insertion of a total hip arthroplasty implant, exposure values increased threefold at some anatomic locations and surpassed 1 mSv, the generally accepted threshold for concern. Radiation exposure to radiosensitive organs increased up to threefold after total hip implantation with automatic exposure control and up to approximately 1.5 times with the manual protocol. Doses were greater with manual exposures than with automatic exposure control (except at the control probe on the stomach, where exposure was negligible, as expected). However, after implant placement, doses increased more with automatic exposure control than with manual exposure. This difference can be attributed to increased scatter and the difficulty of dose modification because of the density of the implant. Current radiographic protocols should be reassessed to determine if the benefits of frequent radiographs outweigh the newly demonstrated risks.
GMP-conformant on-site manufacturing of a CD133+ stem cell product for cardiovascular regeneration.
Skorska, Anna; Müller, Paula; Gaebel, Ralf; Große, Jana; Lemcke, Heiko; Lux, Cornelia A; Bastian, Manuela; Hausburg, Frauke; Zarniko, Nicole; Bubritzki, Sandra; Ruch, Ulrike; Tiedemann, Gudrun; David, Robert; Steinhoff, Gustav
2017-02-10
CD133 + stem cells represent a promising subpopulation for innovative cell-based therapies in cardiovascular regeneration. Several clinical trials have shown remarkable beneficial effects following their intramyocardial transplantation. Yet, the purification of CD133 + stem cells is typically performed in centralized clean room facilities using semi-automatic manufacturing processes based on magnetic cell sorting (MACS®). However, this requires time-consuming and cost-intensive logistics. CD133 + stem cells were purified from patient-derived sternal bone marrow using the recently developed automatic CliniMACS Prodigy® BM-133 System (Prodigy). The entire manufacturing process, as well as the subsequent quality control of the final cell product (CP), were realized on-site and in compliance with EU guidelines for Good Manufacturing Practice. The biological activity of automatically isolated CD133 + cells was evaluated and compared to manually isolated CD133 + cells via functional assays as well as immunofluorescence microscopy. In addition, the regenerative potential of purified stem cells was assessed 3 weeks after transplantation in immunodeficient mice which had been subjected to experimental myocardial infarction. We established for the first time an on-site manufacturing procedure for stem CPs intended for the treatment of ischemic heart diseases using an automatized system. On average, 0.88 × 10 6 viable CD133 + cells with a mean log 10 depletion of 3.23 ± 0.19 of non-target cells were isolated. Furthermore, we demonstrated that these automatically isolated cells bear proliferation and differentiation capacities comparable to manually isolated cells in vitro. Moreover, the automatically generated CP shows equal cardiac regeneration potential in vivo. Our results indicate that the Prodigy is a powerful system for automatic manufacturing of a CD133 + CP within few hours. Compared to conventional manufacturing processes, future clinical application of this system offers multiple benefits including stable CP quality and on-site purification under reduced clean room requirements. This will allow saving of time, reduced logistics and diminished costs.
NASA Technical Reports Server (NTRS)
Orr, James K.; Peltier, Daryl
2010-01-01
Thsi slide presentation reviews the avionics software system on board the space shuttle, with particular emphasis on the quality and reliability. The Primary Avionics Software System (PASS) provides automatic and fly-by-wire control of critical shuttle systems which executes in redundant computers. Charts given show the number of space shuttle flights vs time, PASS's development history, and other charts that point to the reliability of the system's development. The reliability of the system is also compared to predicted reliability.
The integrated manual and automatic control of complex flight systems
NASA Technical Reports Server (NTRS)
Schmidt, D. K.
1986-01-01
The topics of research in this program include pilot/vehicle analysis techniques, identification of pilot dynamics, and control and display synthesis techniques for optimizing aircraft handling qualities. The project activities are discussed. The current technical activity is directed at extending and validating the active display synthesis procedure, and the pilot/vehicle analysis of the NLR rate-command flight configurations in the landing task. Two papers published by the researchers are attached as appendices.
Effect of egg freshness on their automatic orientation.
Jiang, Song; Zhu, Ticao; Jia, Danfeng; Yao, Jun; Jiang, Yiyi
2018-05-01
High-quality eggs in unified packaging are desired by egg production enterprises. Automatic orientation apparatus is frequently used to orient eggs uniformly to pointed-end-down position for packaging. However, such apparatus may not work accordingly if the eggs are stored under improper methods or for excessive storage time. To study the effect of egg freshness on the efficiency of automatic orientation process, the relationship between egg freshness and its orientation motions was investigated under different storage conditions. The results showed that as the storage time increased, centroid position and pointed-end-down turnover ratio decreased; other parameters such as eggs' obliquity at stationary state, horizontal deflection angle, speed, acceleration of axial motion, side-slip angle and rolling distance increased. However, the effects of storage time on the guiding distance of the guide rod were not apparent. In addition, the higher the storage temperature, the greater the changes of the final orientation states of eggs on the conveyor line. If the eggs were to be oriented uniformly, they should be stored for less than 25, 16, 10 and 7 days at 10 °C, 18 °C, 26 °C and 34 °C, respectively, under a relative humidity of 75%. The experimental results presented in this paper are very useful for quality control and quality assurance in egg production enterprises. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Presley, Todd K.; Jamison, Marcael T.J.; Young, Stacie T.M.
2008-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. The program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream and to assess the effects from the H-1 storm drain on Manoa Stream. For this program, rainfall data were collected at three stations, continuous discharge data at four stations, and water-quality data at six stations, which include the four continuous discharge stations. This report summarizes rainfall, discharge, and water-quality data collected between July 1, 2007, and June 30, 2008. A total of 16 environmental samples were collected over two storms during July 1, 2007, to June 30, 2008, within the Halawa Stream drainage area. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, and zinc). Additionally, grab samples were analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Some samples were analyzed for only a partial list of these analytes because an insufficient volume of sample was collected by the automatic samplers. Three additional quality-assurance/quality-control samples were collected concurrently with the storm samples. A total of 16 environmental samples were collected over four storms during July 1, 2007, to June 30, 2008 at the H-1 Storm Drain. All samples at this site were collected using an automatic sampler. Samples generally were analyzed for total suspended solids, nutrients, chemical oxygen demand, oil and grease, total petroleum hydrocarbons, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc), although some samples were analyzed for only a partial list of these analytes. During the storm of January 29, 2008, 10 discrete samples were collected. Varying constituent concentrations were detected for the samples collected at different times during this storm event. Two quality-assurance/quality-control samples were collected concurrently with the storm samples. Three additional quality-assurance/quality-control samples were collected during routine sampler maintenance to check the effectiveness of equipment-cleaning procedures.
Gyssels, Elodie; Bohy, Pascale; Cornil, Arnaud; van Muylem, Alain; Howarth, Nigel; Gevenois, Pierre A; Tack, Denis
2016-01-01
The aim of the study was to compare radiation dose and image quality between the "average" and the "very strong" automatic exposure control (AEC) strength curves. Images reconstructed with filtered back-projection techniques and radiation dose data of unenhanced helical chest computed tomography (CT) examinations obtained at 2 hospitals (hospital A, hospital B) using the same scanner devices and acquisition protocols but different AEC strength curves were evaluated over a 3-month period. The selected AEC strength curve applied to "slim" patients (diameter <32 cm estimated from the attenuation automatically measured on the topogram) was "average" and "very strong" in hospital A and hospital B, respectively. Two radiologists with 13 and 24 years of experience scored the image quality of the lung parenchyma and the mediastinum on a 5-point scale. The patients' effective diameter, the delivered CT dose index volume, and dose-length products were recorded. A total of 410 patients were included. The average body mass index was 24.0 kg/m in hospital A and 24.8 kg/m in hospital B. There was no significant difference between hospitals with respect to age, sex ratio, weight, height, body mass index, effective diameters, and image quality scores for each radiologist (P ranging from 0.050 to 1.000). The mean CT dose index volume for the entire population was 2.0 mGy and was significantly lower in hospital B with the "very strong" AEC curve as compared with hospital A (-11%, P=0.001). The mean dose-length product delivered in this 70 kg-weight population was 68 mGy cm, corresponding to an effective dose of 0.95 mSv. Changing the AEC strength curve from "average" to "very strong" for slim patients maintains image quality and reduces the radiation dose to <1 mSv in routine chest CT examinations reconstructed with filtered back-projection techniques.
Nowik, Patrik; Bujila, Robert; Poludniowski, Gavin; Fransson, Annette
2015-07-08
The purpose of this study was to develop a method of performing routine periodical quality controls (QC) of CT systems by automatically analyzing key performance indicators (KPIs), obtainable from images of manufacturers' quality assurance (QA) phantoms. A KPI pertains to a measurable or determinable QC parameter that is influenced by other underlying fundamental QC parameters. The established KPIs are based on relationships between existing QC parameters used in the annual testing program of CT scanners at the Karolinska University Hospital in Stockholm, Sweden. The KPIs include positioning, image noise, uniformity, homogeneity, the CT number of water, and the CT number of air. An application (MonitorCT) was developed to automatically evaluate phantom images in terms of the established KPIs. The developed methodology has been used for two years in clinical routine, where CT technologists perform daily scans of the manufacturer's QA phantom and automatically send the images to MonitorCT for KPI evaluation. In the cases where results were out of tolerance, actions could be initiated in less than 10 min. 900 QC scans from two CT scanners have been collected and analyzed over the two-year period that MonitorCT has been active. Two types of errors have been registered in this period: a ring artifact was discovered with the image noise test, and a calibration error was detected multiple times with the CT number test. In both cases, results were outside the tolerances defined for MonitorCT, as well as by the vendor. Automated monitoring of KPIs is a powerful tool that can be used to supplement established QC methodologies. Medical physicists and other professionals concerned with the performance of a CT system will, using such methods, have access to comprehensive data on the current and historical (trend) status of the system such that swift actions can be taken in order to ensure the quality of the CT examinations, patient safety, and minimal disruption of service.
Set Up of an Automatic Water Quality Sampling System in Irrigation Agriculture
Heinz, Emanuel; Kraft, Philipp; Buchen, Caroline; Frede, Hans-Georg; Aquino, Eugenio; Breuer, Lutz
2014-01-01
We have developed a high-resolution automatic sampling system for continuous in situ measurements of stable water isotopic composition and nitrogen solutes along with hydrological information. The system facilitates concurrent monitoring of a large number of water and nutrient fluxes (ground, surface, irrigation and rain water) in irrigated agriculture. For this purpose we couple an automatic sampling system with a Wavelength-Scanned Cavity Ring Down Spectrometry System (WS-CRDS) for stable water isotope analysis (δ2H and δ18O), a reagentless hyperspectral UV photometer (ProPS) for monitoring nitrate content and various water level sensors for hydrometric information. The automatic sampling system consists of different sampling stations equipped with pumps, a switch cabinet for valve and pump control and a computer operating the system. The complete system is operated via internet-based control software, allowing supervision from nearly anywhere. The system is currently set up at the International Rice Research Institute (Los Baños, The Philippines) in a diversified rice growing system to continuously monitor water and nutrient fluxes. Here we present the system's technical set-up and provide initial proof-of-concept with results for the isotopic composition of different water sources and nitrate values from the 2012 dry season. PMID:24366178
Paver automation for road surfacing
NASA Astrophysics Data System (ADS)
Tihonov, A.; Velichkin, V.
2017-10-01
The paper discusses factors that bear on the quality of motor road pavement as access roads and highways are built and used. A block diagram is proposed to organize elements of the automatic control system to control the asphalt paver’s mechanisms; the system is based on a microprocessor onboard controller to maintain preset elevation of the finishing plate; description of its operation principle is offered. The paper names primary converters to control the finishing plate elevation. A new control method is described to control the machine’s straight-line movement with GLONASS Satellite Positioning System (SPS) during operation.
Machine learning approach for automatic quality criteria detection of health web pages.
Gaudinat, Arnaud; Grabar, Natalia; Boyer, Célia
2007-01-01
The number of medical websites is constantly growing [1]. Owing to the open nature of the Web, the reliability of information available on the Web is uneven. Internet users are overwhelmed by the quantity of information available on the Web. The situation is even more critical in the medical area, as the content proposed by health websites can have a direct impact on the users' well being. One way to control the reliability of health websites is to assess their quality and to make this assessment available to users. The HON Foundation has defined a set of eight ethical principles. HON's experts are working in order to manually define whether a given website complies with s the required principles. As the number of medical websites is constantly growing, manual expertise becomes insufficient and automatic systems should be used in order to help medical experts. In this paper we present the design and the evaluation of an automatic system conceived for the categorisation of medical and health documents according to he HONcode ethical principles. A first evaluation shows promising results. Currently the system shows 0.78 micro precision and 0.73 F-measure, with 0.06 errors.
Mark, Daniel B.; Anstrom, Kevin J.; McNulty, Steven E.; Flaker, Greg C.; Tonkin, Andrew M.; Smith, Warren M.; Toff, William D.; Dorian, Paul; Clapp-Channing, Nancy E.; Anderson, Jill; Johnson, George; Schron, Eleanor B.; Poole, Jeanne E.; Lee, Kerry L.; Bardy, Gust H.
2010-01-01
Background Public access automatic external defibrillators (AEDs) can save lives, but most deaths from out-of-hospital sudden cardiac arrest occur at home. The Home Automatic External Defibrillator Trial (HAT) found no survival advantage for adding a home AED to cardiopulmonary resuscitation (CPR) training for 7001 patients with a prior anterior wall myocardial infarction. Quality of life (QOL) outcomes for both the patient and spouse/companion were secondary endpoints. Methods A subset of 1007 study patients and their spouse/companions was randomly selected for ascertainment of QOL by structured interview at baseline and 12 and 24 months following enrollment. The primary QOL measures were the Medical Outcomes Study 36-Item Short-Form (SF-36) psychological well-being (reflecting anxiety and depression) and vitality (reflecting energy and fatigue) subscales. Results For patients and spouse/companions, the psychological well-being and vitality scales did not differ significantly between those randomly assigned an AED plus CPR training and controls who received CPR training only. None of the other QOL measures collected showed a clinically and statistically significant difference between treatment groups. Patients in the AED group were more likely to report being extremely or quite a bit reassured by their treatment assignment. Spouse/companions in the AED group reported being less often nervous about the possibility of using AED/CPR treatment than those in the CPR group. Conclusions Adding access to a home AED to CPR training did not affect quality of life either for patients with a prior anterior myocardial infarction or their spouse/companion but did provide more reassurance to the patients without increasing anxiety for spouse/companions. PMID:20362722
New conversion factors between human and automatic readouts of the CDMAM phantom for CR systems
NASA Astrophysics Data System (ADS)
Hummel, Johann; Homolka, Peter; Osanna-Elliot, Angelika; Kaar, Marcus; Semtrus, Friedrich; Figl, Michael
2016-03-01
Mammography screenings demand for profound image quality (IQ) assessment to guarantee their screening success. The European protocol for the quality control of the physical and technical aspects of mammography screening (EPQCM) suggests a contrast detail phantom such as the CDMAM phantom to evaluate IQ. For automatic evaluation a software is provided by the EUREF. As human and automatic readouts differ systematically conversion factors were published by the official reference organisation (EUREF). As we experienced a significant difference for these factors for Computed Radiography (CR) systems we developed an objectifying analysis software which presents the cells including the gold disks randomly in thickness and rotation. This allows to overcome the problem of an inevitable learning effect where observers know the position of the disks in advance. Applying this software, 45 computed radiography (CR) systems were evaluated and the conversion factors between human and automatic readout determined. The resulting conversion factors were compared with the ones resulting from the two methods published by EUREF. We found our conversion factors to be substantially lower than those suggested by EUREF, in particular 1.21 compared to 1.42 (EUREF EU method) and 1.62 (EUREF UK method) for 0.1 mm, and 1.40 compared to 1.73 (EUREF EU) and 1.83 (EUREF UK) for 0.25 mm disc diameter, respectively. This can result in a dose increase of up to 90% using either of these factors to adjust patient dose in order to fulfill image quality requirements. This suggests the need of an agreement on their proper application and limits the validity of the assessment methods. Therefore, we want to stress the need for clear criteria for CR systems based on appropriate studies.
Nájera, S; Gil-Martínez, M; Zambrano, J A
2015-01-01
The aim of this paper is to establish and quantify different operational goals and control strategies in autothermal thermophilic aerobic digestion (ATAD). This technology appears as an alternative to conventional sludge digestion systems. During the batch-mode reaction, high temperatures promote sludge stabilization and pasteurization. The digester temperature is usually the only online, robust, measurable variable. The average temperature can be regulated by manipulating both the air injection and the sludge retention time. An improved performance of diverse biochemical variables can be achieved through proper manipulation of these inputs. However, a better quality of treated sludge usually implies major operating costs or a lower production rate. Thus, quality, production and cost indices are defined to quantify the outcomes of the treatment. Based on these, tradeoff control strategies are proposed and illustrated through some examples. This paper's results are relevant to guide plant operators, to design automatic control systems and to compare or evaluate the control performance on ATAD systems.
Online devices and measuring systems for the automatic control of newspaper printing
NASA Astrophysics Data System (ADS)
Marszalec, Elzbieta A.; Heikkila, Ismo; Juhola, Helene; Lehtonen, Tapio
1999-09-01
The paper reviews the state-of-the-art color measuring systems used for the control of newspaper printing. The printing process requirements are specified and different off-line and on-line color quality control systems, commercially available and under development, are evaluated. Recent market trends in newspaper printing are discussed based on the survey. The study was made on information derived from: conference proceedings (TAGA, IARIGAI, SPIE and IS&T), journals (American Printer, Applied Optics), discussions with experts (GMI, QTI, HONEYWELL, TOBIAS, GretagMacbeth), IFRA Expo'98/Quality Measuring Technologies, commercial brochures, and the Internet. On the background of this review, three different measuring principles, currently, under investigation at VTT Information Technology, are described and their applicability to newspaper printing is evaluated.
NASA Astrophysics Data System (ADS)
Noh, Myoung-Jong; Howat, Ian M.
2018-02-01
The quality and efficiency of automated Digital Elevation Model (DEM) extraction from stereoscopic satellite imagery is critically dependent on the accuracy of the sensor model used for co-locating pixels between stereo-pair images. In the absence of ground control or manual tie point selection, errors in the sensor models must be compensated with increased matching search-spaces, increasing both the computation time and the likelihood of spurious matches. Here we present an algorithm for automatically determining and compensating the relative bias in Rational Polynomial Coefficients (RPCs) between stereo-pairs utilizing hierarchical, sub-pixel image matching in object space. We demonstrate the algorithm using a suite of image stereo-pairs from multiple satellites over a range stereo-photogrammetrically challenging polar terrains. Besides providing a validation of the effectiveness of the algorithm for improving DEM quality, experiments with prescribed sensor model errors yield insight into the dependence of DEM characteristics and quality on relative sensor model bias. This algorithm is included in the Surface Extraction through TIN-based Search-space Minimization (SETSM) DEM extraction software package, which is the primary software used for the U.S. National Science Foundation ArcticDEM and Reference Elevation Model of Antarctica (REMA) products.
Oregon Washington Coastal Ocean Forecast System: Real-time Modeling and Data Assimilation
NASA Astrophysics Data System (ADS)
Erofeeva, S.; Kurapov, A. L.; Pasmans, I.
2016-02-01
Three-day forecasts of ocean currents, temperature and salinity along the Oregon and Washington coasts are produced daily by a numerical ROMS-based ocean circulation model. NAM is used to derive atmospheric forcing for the model. Fresh water discharge from Columbia River, Fraser River, and small rivers in Puget Sound are included. The forecast is constrained by open boundary conditions derived from the global Navy HYCOM model and once in 3 days assimilation of recent data, including HF radar surface currents, sea surface temperature from the GOES satellite, and SSH from several satellite altimetry missions. 4-dimensional variational data assimilation is implemented in 3-day time windows using the tangent linear and adjoint codes developed at OSU. The system is semi-autonomous - all the data, including NAM and HYCOM fields are automatically updated, and daily operational forecast is automatically initiated. The pre-assimilation data quality control and post-assimilation forecast quality control require the operator's involvement. The daily forecast and 60 days of hindcast fields are available for public on opendap. As part of the system model validation plots to various satellites and SEAGLIDER are also automatically updated and available on the web (http://ingria.coas.oregonstate.edu/rtdavow/). Lessons learned in this pilot real-time coastal ocean forecasting project help develop and test metrics for forecast skill assessment for the West Coast Operational Forecast System (WCOFS), currently at testing and development phase at the National Oceanic and Atmospheric Administration (NOAA).
Control of arc length during gas metal arc welding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Madigan, R.B.; Quinn, T.P.
1994-12-31
An arc-length control system has been developed for gas metal arc welding (GMAW) under spray transfer welding conditions. The ability to monitor and control arc length during arc welding allows consistent weld characteristics to be maintained and therefore improves weld quality. Arc length control has only been implemented for gas tungsten arc welding (GTAW), where an automatic voltage control (AVC) unit adjusts torch-to-work distance. The system developed here compliments the voltage- and current-sensing techniques commonly used for control of GMAW. The system consists of an arc light intensity sensor (photodiode), a Hall-effect current sensor, a personal computer and software implementingmore » a data interpretation and control algorithms. Arc length was measured using both arc light and arc current signals. Welding current was adjusted to maintain constant arc length. A proportional-integral-derivative (PID) controller was used. Gains were automatically selected based on the desired welding conditions. In performance evaluation welds, arc length varied from 2.5 to 6.5 mm while welding up a sloped workpiece (ramp in CTWD) without the control. Arc length was maintained within 1 mm of the desired (5 mm ) with the control.« less
NASA Astrophysics Data System (ADS)
Krokhin, G.; Pestunov, A.; Arakelyan, E.; Mukhin, V.
2017-11-01
During the last decades, there can be noticed an increase of interest concerning various aspects of intellectual diagnostics and management in thermal power engineering according the hybrid principle. It is conditioned by the fact that conservative static methods does not allow to reflect the actual power installation state adequately. In order to improve the diagnostics quality, we use various fuzzy systems apparatus. In this paper, we introduce the intellectual system, called SKAIS, which is intended for quick and precise diagnostics of thermal power equipment. This system was developed as the result of the research carried out by specialists from National Research University “Moscow Power Engineering Institute” and Novosibirsk State University of Economics and Management. It drastically increases the level of intelligence of the automatic power plant control system.
Linking quality indicators to clinical trials: an automated approach
Coiera, Enrico; Choong, Miew Keen; Tsafnat, Guy; Hibbert, Peter; Runciman, William B.
2017-01-01
Abstract Objective Quality improvement of health care requires robust measurable indicators to track performance. However identifying which indicators are supported by strong clinical evidence, typically from clinical trials, is often laborious. This study tests a novel method for automatically linking indicators to clinical trial registrations. Design A set of 522 quality of care indicators for 22 common conditions drawn from the CareTrack study were automatically mapped to outcome measures reported in 13 971 trials from ClinicalTrials.gov. Intervention Text mining methods extracted phrases mentioning indicators and outcome phrases, and these were compared using the Levenshtein edit distance ratio to measure similarity. Main Outcome Measure Number of care indicators that mapped to outcome measures in clinical trials. Results While only 13% of the 522 CareTrack indicators were thought to have Level I or II evidence behind them, 353 (68%) could be directly linked to randomized controlled trials. Within these 522, 50 of 70 (71%) Level I and II evidence-based indicators, and 268 of 370 (72%) Level V (consensus-based) indicators could be linked to evidence. Of the indicators known to have evidence behind them, only 5.7% (4 of 70) were mentioned in the trial reports but were missed by our method. Conclusions We automatically linked indicators to clinical trial registrations with high precision. Whilst the majority of quality indicators studied could be directly linked to research evidence, a small portion could not and these require closer scrutiny. It is feasible to support the process of indicator development using automated methods to identify research evidence. PMID:28651340
Sirgo, Gonzalo; Esteban, Federico; Gómez, Josep; Moreno, Gerard; Rodríguez, Alejandro; Blanch, Lluis; Guardiola, Juan José; Gracia, Rafael; De Haro, Lluis; Bodí, María
2018-04-01
Big data analytics promise insights into healthcare processes and management, improving outcomes while reducing costs. However, data quality is a major challenge for reliable results. Business process discovery techniques and an associated data model were used to develop data management tool, ICU-DaMa, for extracting variables essential for overseeing the quality of care in the intensive care unit (ICU). To determine the feasibility of using ICU-DaMa to automatically extract variables for the minimum dataset and ICU quality indicators from the clinical information system (CIS). The Wilcoxon signed-rank test and Fisher's exact test were used to compare the values extracted from the CIS with ICU-DaMa for 25 variables from all patients attended in a polyvalent ICU during a two-month period against the gold standard of values manually extracted by two trained physicians. Discrepancies with the gold standard were classified into plausibility, conformance, and completeness errors. Data from 149 patients were included. Although there were no significant differences between the automatic method and the manual method, we detected differences in values for five variables, including one plausibility error and two conformance and completeness errors. Plausibility: 1) Sex, ICU-DaMa incorrectly classified one male patient as female (error generated by the Hospital's Admissions Department). Conformance: 2) Reason for isolation, ICU-DaMa failed to detect a human error in which a professional misclassified a patient's isolation. 3) Brain death, ICU-DaMa failed to detect another human error in which a professional likely entered two mutually exclusive values related to the death of the patient (brain death and controlled donation after circulatory death). Completeness: 4) Destination at ICU discharge, ICU-DaMa incorrectly classified two patients due to a professional failing to fill out the patient discharge form when thepatients died. 5) Length of continuous renal replacement therapy, data were missing for one patient because the CRRT device was not connected to the CIS. Automatic generation of minimum dataset and ICU quality indicators using ICU-DaMa is feasible. The discrepancies were identified and can be corrected by improving CIS ergonomics, training healthcare professionals in the culture of the quality of information, and using tools for detecting and correcting data errors. Copyright © 2018 Elsevier B.V. All rights reserved.
Comparison of automatic control systems
NASA Technical Reports Server (NTRS)
Oppelt, W
1941-01-01
This report deals with a reciprocal comparison of an automatic pressure control, an automatic rpm control, an automatic temperature control, and an automatic directional control. It shows the difference between the "faultproof" regulator and the actual regulator which is subject to faults, and develops this difference as far as possible in a parallel manner with regard to the control systems under consideration. Such as analysis affords, particularly in its extension to the faults of the actual regulator, a deep insight into the mechanism of the regulator process.
NASA Astrophysics Data System (ADS)
Liu, Lei; Chen, Wu; Wang, Huagang; Ba, Jinyu; Li, Bing
2017-12-01
The repair of nuclear spent fuel pool has a high requirement for the quality of welding, the welding speed directly affects the quality of the weld when local dry automatic underwater welding is used to repair the damaged surface. Under the condition of the same condition, the local dry automatic underwater welding test was carried out under the condition of the same welding condition. Taking the 20cm as the experimental condition, after massive experiments show that when the welding speed is approximately 48cm/min the weld quality is high, meeting the design requirements, based on the double layer shrinkage nozzle chamber of local dry underwater automatic welding.
Automatic Overset Grid Generation with Heuristic Feedback Control
NASA Technical Reports Server (NTRS)
Robinson, Peter I.
2001-01-01
An advancing front grid generation system for structured Overset grids is presented which automatically modifies Overset structured surface grids and control lines until user-specified grid qualities are achieved. The system is demonstrated on two examples: the first refines a space shuttle fuselage control line until global truncation error is achieved; the second advances, from control lines, the space shuttle orbiter fuselage top and fuselage side surface grids until proper overlap is achieved. Surface grids are generated in minutes for complex geometries. The system is implemented as a heuristic feedback control (HFC) expert system which iteratively modifies the input specifications for Overset control line and surface grids. It is developed as an extension of modern control theory, production rules systems and subsumption architectures. The methodology provides benefits over the full knowledge lifecycle of an expert system for knowledge acquisition, knowledge representation, and knowledge execution. The vector/matrix framework of modern control theory systematically acquires and represents expert system knowledge. Missing matrix elements imply missing expert knowledge. The execution of the expert system knowledge is performed through symbolic execution of the matrix algebra equations of modern control theory. The dot product operation of matrix algebra is generalized for heuristic symbolic terms. Constant time execution is guaranteed.
Design and Implementation of Multifunctional Automatic Drilling End Effector
NASA Astrophysics Data System (ADS)
Wang, Zhanxi; Qin, Xiansheng; Bai, Jing; Tan, Xiaoqun; Li, Jing
2017-03-01
In order to realize the automatic drilling in aircraft assembly, a drilling end effector is designed by integrating the pressure unit, drilling unit, measurement unit, control system and frame structure. In order to reduce the hole deviation, this paper proposes a vertical normal adjustment program based on 4 laser distance sensors. The actual normal direction of workpiece surface can be calculated through the sensors measurements, and then robot posture is adjusted to realize the hole deviation correction. A base detection method is proposed to detect and locate the hole automatically by using the camera and the reference hole. The experiment results show that the position accuracy of the system is less than 0.3mm, and the normal precision is less than 0.5°. The drilling end effector and robot can greatly improve the efficiency of the aircraft parts and assembly quality, and reduce the product development cycle.
49 CFR 236.825 - System, automatic train control.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false System, automatic train control. 236.825 Section..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.825 System, automatic train control. A system so arranged that its operation will automatically...
49 CFR 236.825 - System, automatic train control.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false System, automatic train control. 236.825 Section..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.825 System, automatic train control. A system so arranged that its operation will automatically...
Adaptive pseudolinear compensators of dynamic characteristics of automatic control systems
NASA Astrophysics Data System (ADS)
Skorospeshkin, M. V.; Sukhodoev, M. S.; Timoshenko, E. A.; Lenskiy, F. V.
2016-04-01
Adaptive pseudolinear gain and phase compensators of dynamic characteristics of automatic control systems are suggested. The automatic control system performance with adaptive compensators has been explored. The efficiency of pseudolinear adaptive compensators in the automatic control systems with time-varying parameters has been demonstrated.
Greene, Beth G; Logan, John S; Pisoni, David B
1986-03-01
We present the results of studies designed to measure the segmental intelligibility of eight text-to-speech systems and a natural speech control, using the Modified Rhyme Test (MRT). Results indicated that the voices tested could be grouped into four categories: natural speech, high-quality synthetic speech, moderate-quality synthetic speech, and low-quality synthetic speech. The overall performance of the best synthesis system, DECtalk-Paul, was equivalent to natural speech only in terms of performance on initial consonants. The findings are discussed in terms of recent work investigating the perception of synthetic speech under more severe conditions. Suggestions for future research on improving the quality of synthetic speech are also considered.
Optimization of the central automatic control of a small Dutch sewer system
NASA Astrophysics Data System (ADS)
Kolechkina, A. G.; Hoes, O. A. C.
2012-04-01
A sewer control system was developed in the context of a subsidized project aiming at improvement of surface water quality by control of sewer systems and surface water systems. The project was coordinated by the local water board, "Waterschap Hollandse Delta". Other participants were Delft University of Technology, Deltares and the municipalities Strijen, Cromstrijen, Westmaas, Oud Beijerland and Piershil. As part of the project there were two pilot implementations where a central automatic controller was coupled to the existing SCADA system. For these two pilots the system is now operational. A Dutch urban area in the western part of the Netherlands is usually part of a polder, which is effectively an artificially drained catchment. The urban area itself is split into small subcatchments that manage runoff in different ways. In all cases a large fraction goes into the natural hydrological cycle, but, depending on the design of the local sewer system, a larger or smaller part finds its way into the sewer system. Proper control of this flow is necessary to control surface water quality and to avoid health risks from flow from the sewer into the streets. At each time step the controller switches pumps to distribute the remaining water in the system at the end of the time step over the different subcatchments. The distribution is created based on expert judgment of the relative vulnerability and subcatchment sewer system water quality. It is implemented in terms curves of total system stored volume versus subcatchment stored volume. We describe the process of the adaptation of a controller to two different sewer systems and the understanding of the artificial part of the catchment we gained during this process. In the process of adaptation the type of sewer system (combined foul water and storm water transport or separate foul water and storm water transport) played a major role.
A training approach to improve stepping automaticity while dual-tasking in Parkinson's disease
Chomiak, Taylor; Watts, Alexander; Meyer, Nicole; Pereira, Fernando V.; Hu, Bin
2017-01-01
Abstract Background: Deficits in motor movement automaticity in Parkinson's disease (PD), especially during multitasking, are early and consistent hallmarks of cognitive function decline, which increases fall risk and reduces quality of life. This study aimed to test the feasibility and potential efficacy of a wearable sensor-enabled technological platform designed for an in-home music-contingent stepping-in-place (SIP) training program to improve step automaticity during dual-tasking (DT). Methods: This was a 4-week prospective intervention pilot study. The intervention uses a sensor system and algorithm that runs off the iPod Touch which calculates step height (SH) in real-time. These measurements were then used to trigger auditory (treatment group, music; control group, radio podcast) playback in real-time through wireless headphones upon maintenance of repeated large amplitude stepping. With small steps or shuffling, auditory playback stops, thus allowing participants to use anticipatory motor control to regain positive feedback. Eleven participants were recruited from an ongoing trial (Trial Number: ISRCTN06023392). Fear of falling (FES-I), general cognitive functioning (MoCA), self-reported freezing of gait (FOG-Q), and DT step automaticity were evaluated. Results: While we found no significant effect of training on FES-I, MoCA, or FOG-Q, we did observe a significant group (music vs podcast) by training interaction in DT step automaticity (P<0.01). Conclusion: Wearable device technology can be used to enable musically-contingent SIP training to increase motor automaticity for people living with PD. The training approach described here can be implemented at home to meet the growing demand for self-management of symptoms by patients. PMID:28151878
Dong, Yi; Fang, Kun; Wang, Xin; Chen, Shengdi; Liu, Xueyuan; Zhao, Yuwu; Guan, Yangtai; Cai, Dingfang; Li, Gang; Liu, Jianmin; Liu, Jianren; Zhuang, Jianhua; Wang, Panshi; Chen, Xin; Shen, Haipeng; Wang, David Z; Xian, Ying; Feng, Wuwei; Campbell, Bruce Cv; Parsons, Mark; Dong, Qiang
2018-07-01
Background Several stroke outcome and quality control projects have demonstrated the success in stroke care quality improvement through structured process. However, Chinese health-care systems are challenged with its overwhelming numbers of patients, limited resources, and large regional disparities. Aim To improve quality of stroke care to address regional disparities through process improvement. Method and design The Shanghai Stroke Service System (4S) is established as a regional network for stroke care quality improvement in the Shanghai metropolitan area. The 4S registry uses a web-based database that automatically extracts data from structured electronic medical records. Site-specific education and training program will be designed and administrated according to their baseline characteristics. Both acute reperfusion therapies including thrombectomy and thrombolysis in the acute phase and subsequent care were measured and monitored with feedback. Primary outcome is to evaluate the differences in quality metrics between baseline characteristics (including rate of thrombolysis in acute stroke and key performance indicators in secondary prevention) and post-intervention. Conclusions The 4S system is a regional stroke network that monitors the ongoing stroke care quality in Shanghai. This project will provide the opportunity to evaluate the spectrum of acute stroke care and design quality improvement processes for better stroke care. A regional stroke network model for quality improvement will be explored and might be expanded to other large cities in China. Clinical Trial Registration-URL http://www.clinicaltrials.gov . Unique identifier: NCT02735226.
NASA Astrophysics Data System (ADS)
Kim, Kyo-Tae; Yun, Ryang-Young; Han, Moo-Jae; Heo, Ye-Ji; Song, Yong-Keun; Heo, Sung-Wook; Oh, Kyeong-Min; Park, Sung-Kwang
2017-10-01
Currently, in the radiation diagnosis field, mammography is used for the early detection of breast cancer. In addition, studies are being conducted on a grid to produce high-quality images. Although the grid ratio of the grid, which affects the scattering removal rate, must be increased to improve image quality, it increases the total exposure dose. While the use of automatic exposure control is recommended to minimize this problem, existing mammography equipment, unlike general radiography equipment, is mounted on the back of a detector. Therefore, the device is greatly affected by the detector and supporting device, and it is difficult to control the exposure dose. Accordingly, in this research, an integrated AEC-grid device that simultaneously performs AEC and grid functions was used to minimize the unnecessary exposure dose while removing scattering, thereby realizing superior image quality.
Stewart, Brandon D; Payne, B Keith
2008-10-01
The evidence for whether intentional control strategies can reduce automatic stereotyping is mixed. Therefore, the authors tested the utility of implementation intentions--specific plans linking a behavioral opportunity to a specific response--in reducing automatic bias. In three experiments, automatic stereotyping was reduced when participants made an intention to think specific counterstereotypical thoughts whenever they encountered a Black individual. The authors used two implicit tasks and process dissociation analysis, which allowed them to separate contributions of automatic and controlled thinking to task performance. Of importance, the reduction in stereotyping was driven by a change in automatic stereotyping and not controlled thinking. This benefit was acquired with little practice and generalized to novel faces. Thus, implementation intentions may be an effective and efficient means for controlling automatic aspects of thought.
Automatic, nondestructive test monitors in-process weld quality
NASA Technical Reports Server (NTRS)
Deal, F. C.
1968-01-01
Instrument automatically and nondestructively monitors the quality of welds produced in microresistance welding. It measures the infrared energy generated in the weld as the weld is made and compares this energy with maximum and minimum limits of infrared energy values previously correlated with acceptable weld-strength tolerances.
14 CFR 25.904 - Automatic takeoff thrust control system (ATTCS).
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Automatic takeoff thrust control system... Automatic takeoff thrust control system (ATTCS). Each applicant seeking approval for installation of an engine power control system that automatically resets the power or thrust on the operating engine(s) when...
14 CFR 25.904 - Automatic takeoff thrust control system (ATTCS).
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Automatic takeoff thrust control system... Automatic takeoff thrust control system (ATTCS). Each applicant seeking approval for installation of an engine power control system that automatically resets the power or thrust on the operating engine(s) when...
30 CFR 77.1401 - Automatic controls and brakes.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic controls and brakes. 77.1401 Section... MINES Personnel Hoisting § 77.1401 Automatic controls and brakes. Hoists and elevators shall be equipped with overspeed, overwind, and automatic stop controls and with brakes capable of stopping the elevator...
75 FR 80886 - Ninth Meeting-RTCA Special Committee 220: Automatic Flight Guidance and Control
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-23
... 220: Automatic Flight Guidance and Control AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 220: Automatic Flight Guidance and Control meeting. SUMMARY: The FAA is... for a Special Committee 220: Automatic Flight Guidance and Control meeting. The agenda will include...
2014-01-01
Background We recently demonstrated that quality of spirometry in primary care could markedly improve with remote offline support from specialized professionals. It is hypothesized that implementation of automatic online assessment of quality of spirometry using information and communication technologies may significantly enhance the potential for extensive deployment of a high quality spirometry program in integrated care settings. Objective The objective of the study was to elaborate and validate a Clinical Decision Support System (CDSS) for automatic online quality assessment of spirometry. Methods The CDSS was done through a three step process including: (1) identification of optimal sampling frequency; (2) iterations to build-up an initial version using the 24 standard spirometry curves recommended by the American Thoracic Society; and (3) iterations to refine the CDSS using 270 curves from 90 patients. In each of these steps the results were checked against one expert. Finally, 778 spirometry curves from 291 patients were analyzed for validation purposes. Results The CDSS generated appropriate online classification and certification in 685/778 (88.1%) of spirometry testing, with 96% sensitivity and 95% specificity. Conclusions Consequently, only 93/778 (11.9%) of spirometry testing required offline remote classification by an expert, indicating a potential positive role of the CDSS in the deployment of a high quality spirometry program in an integrated care setting. PMID:25600957
The integrated manual and automatic control of complex flight systems
NASA Technical Reports Server (NTRS)
Schmidt, D. K.
1985-01-01
Pilot/vehicle analysis techniques for optimizing aircraft handling qualities are presented. The analysis approach considered is based on the optimal control frequency domain techniques. These techniques stem from an optimal control approach of a Neal-Smith like analysis on aircraft attitude dynamics extended to analyze the flared landing task. Some modifications to the technique are suggested and discussed. An in depth analysis of the effect of the experimental variables, such as prefilter, is conducted to gain further insight into the flared land task for this class of vehicle dynamics.
An automatic tsunami warning system: TREMORS application in Europe
NASA Astrophysics Data System (ADS)
Reymond, D.; Robert, S.; Thomas, Y.; Schindelé, F.
1996-03-01
An integrated system named TREMORS (Tsunami Risk Evaluation through seismic Moment of a Real-time System) has been installed in EVORA station, in Portugal which has been affected by historical tsunamis. The system is based on a three component long period seismic station linked to a compatible IBM_PC with a specific software. The goals of this system are the followings: detect earthquake, locate them, compute their seismic moment, give a seismic warning. The warnings are based on the seismic moment estimation and all the processing are made automatically. The finality of this study is to check the quality of estimation of the main parameters of interest in a goal of tsunami warning: the location which depends of azimuth and distance, and at last the seismic moment, M 0, which controls the earthquake size. The sine qua non condition for obtaining an automatic location is that the 3 main seismic phases P, S, R must be visible. This study gives satisfying results (automatic analysis): ± 5° errors in azimuth and epicentral distance, and a standard deviation of less than a factor 2 for the seismic moment M 0.
Correlation and registration of ERTS multispectral imagery. [by a digital processing technique
NASA Technical Reports Server (NTRS)
Bonrud, L. O.; Henrikson, P. J.
1974-01-01
Examples of automatic digital processing demonstrate the feasibility of registering one ERTS multispectral scanner (MSS) image with another obtained on a subsequent orbit, and automatic matching, correlation, and registration of MSS imagery with aerial photography (multisensor correlation) is demonstrated. Excellent correlation was obtained with patch sizes exceeding 16 pixels square. Qualities which lead to effective control point selection are distinctive features, good contrast, and constant feature characteristics. Results of the study indicate that more than 300 degrees of freedom are required to register two standard ERTS-1 MSS frames covering 100 by 100 nautical miles to an accuracy of 0.6 pixel mean radial displacement error. An automatic strip processing technique demonstrates 600 to 1200 degrees of freedom over a quater frame of ERTS imagery. Registration accuracies in the range of 0.3 pixel to 0.5 pixel mean radial error were confirmed by independent error analysis. Accuracies in the range of 0.5 pixel to 1.4 pixel mean radial error were demonstrated by semi-automatic registration over small geographic areas.
Automatic indexing in a drug information portal.
Sakji, Saoussen; Letord, Catherine; Dahamna, Badisse; Kergourlay, Ivan; Pereira, Suzanne; Joubert, Michel; Darmoni, Stéfan
2009-01-01
The objective of this work is to create a bilingual (French/English) Drug Information Portal (DIP), in a multi-terminological context and to emphasize its exploitation by an ATC automatic indexing allowing having more pertinent information about substances, organs or systems on which drugs act and their therapeutic and chemical characteristics. The development of the DIP was based on the CISMeF portal, which catalogues and indexes the most important and quality-controlled sources of institutional health information in French. DIP has created specific functionalities and uses specific drugs terminologies such as the ATC classification which used to automatic index the DIP resources. DIP is the result of collaboration between the CISMeF team and the VIDAL Company, specialized in drug information. DIP is conceived to facilitate the user information retrieval. The ATC automatic indexing provided relevant results in 76% of cases. Using multi-terminological context and in the framework of the drug field, indexing drugs with the appropriate codes or/and terms revealed to be very important to have the appropriate information storage and retrieval. The main challenge in the coming year is to increase the accuracy of the approach.
Network design and quality checks in automatic orientation of close-range photogrammetric blocks.
Dall'Asta, Elisa; Thoeni, Klaus; Santise, Marina; Forlani, Gianfranco; Giacomini, Anna; Roncella, Riccardo
2015-04-03
Due to the recent improvements of automatic measurement procedures in photogrammetry, multi-view 3D reconstruction technologies are becoming a favourite survey tool. Rapidly widening structure-from-motion (SfM) software packages offer significantly easier image processing workflows than traditional photogrammetry packages. However, while most orientation and surface reconstruction strategies will almost always succeed in any given task, estimating the quality of the result is, to some extent, still an open issue. An assessment of the precision and reliability of block orientation is necessary and should be included in every processing pipeline. Such a need was clearly felt from the results of close-range photogrammetric surveys of in situ full-scale and laboratory-scale experiments. In order to study the impact of the block control and the camera network design on the block orientation accuracy, a series of Monte Carlo simulations was performed. Two image block configurations were investigated: a single pseudo-normal strip and a circular highly-convergent block. The influence of surveying and data processing choices, such as the number and accuracy of the ground control points, autofocus and camera calibration was investigated. The research highlights the most significant aspects and processes to be taken into account for adequate in situ and laboratory surveys, when modern SfM software packages are used, and evaluates their effect on the quality of the results of the surface reconstruction.
Trust, control strategies and allocation of function in human-machine systems.
Lee, J; Moray, N
1992-10-01
As automated controllers supplant human intervention in controlling complex systems, the operators' role often changes from that of an active controller to that of a supervisory controller. Acting as supervisors, operators can choose between automatic and manual control. Improperly allocating function between automatic and manual control can have negative consequences for the performance of a system. Previous research suggests that the decision to perform the job manually or automatically depends, in part, upon the trust the operators invest in the automatic controllers. This paper reports an experiment to characterize the changes in operators' trust during an interaction with a semi-automatic pasteurization plant, and investigates the relationship between changes in operators' control strategies and trust. A regression model identifies the causes of changes in trust, and a 'trust transfer function' is developed using time series analysis to describe the dynamics of trust. Based on a detailed analysis of operators' strategies in response to system faults we suggest a model for the choice between manual and automatic control, based on trust in automatic controllers and self-confidence in the ability to control the system manually.
Learning diagnostic models using speech and language measures.
Peintner, Bart; Jarrold, William; Vergyriy, Dimitra; Richey, Colleen; Tempini, Maria Luisa Gorno; Ogar, Jennifer
2008-01-01
We describe results that show the effectiveness of machine learning in the automatic diagnosis of certain neurodegenerative diseases, several of which alter speech and language production. We analyzed audio from 9 control subjects and 30 patients diagnosed with one of three subtypes of Frontotemporal Lobar Degeneration. From this data, we extracted features of the audio signal and the words the patient used, which were obtained using our automated transcription technologies. We then automatically learned models that predict the diagnosis of the patient using these features. Our results show that learned models over these features predict diagnosis with accuracy significantly better than random. Future studies using higher quality recordings will likely improve these results.
Analysis of straw row in the image to control the trajectory of the agricultural combine harvester
NASA Astrophysics Data System (ADS)
Shkanaev, Aleksandr Yurievich; Polevoy, Dmitry Valerevich; Panchenko, Aleksei Vladimirovich; Krokhina, Darya Alekseevna; Nailevish, Sadekov Rinat
2018-04-01
The paper proposes a solution to the automatic operation of the combine harvester along the straw rows by means of the images from the camera, installed in the cab of the harvester. The U-Net is used to recognize straw rows in the image. The edges of the row are approximated in the segmented image by the curved lines and further converted into the harvester coordinate system for the automatic operating system. The "new" network architecture and approaches to the row approximation has improved the quality of the recognition task and the processing speed of the frames up to 96% and 7.5 fps, respectively. Keywords: Grain harvester,
76 FR 50809 - Eleventh Meeting: RTCA Special Committee 220: Automatic Flight Guidance and Control
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-16
... Committee 220: Automatic Flight Guidance and Control AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Correction of Notice of RTCA Special Committee 220 meeting: Automatic Flight Guidance and Control...: Automatic Flight Guidance and Control DATES: The meeting will be held September 13-15, 2011, from 9 a.m. to...
Argo workstation: a key component of operational oceanography
NASA Astrophysics Data System (ADS)
Dong, Mingmei; Xu, Shanshan; Miao, Qingsheng; Yue, Xinyang; Lu, Jiawei; Yang, Yang
2018-02-01
Operational oceanography requires the quantity, quality, and availability of data set and the timeliness and effectiveness of data products. Without steady and strong operational system supporting, operational oceanography will never be proceeded far. In this paper we describe an integrated platform named Argo Workstation. It operates as a data processing and management system, capable of data collection, automatic data quality control, visualized data check, statistical data search and data service. After it is set up, Argo workstation provides global high quality Argo data to users every day timely and effectively. It has not only played a key role in operational oceanography but also set up an example for operational system.
A Computer Model of the Evaporator for the Development of an Automatic Control System
NASA Astrophysics Data System (ADS)
Kozin, K. A.; Efremov, E. V.; Kabrysheva, O. P.; Grachev, M. I.
2016-08-01
For the implementation of a closed nuclear fuel cycle it is necessary to carry out a series of experimental studies to justify the choice of technology. In addition, the operation of the radiochemical plant is impossible without high-quality automatic control systems. In the technologies of spent nuclear fuel reprocessing, the method of continuous evaporation is often used for a solution conditioning. Therefore, the effective continuous technological process will depend on the operation of the evaporation equipment. Its essential difference from similar devices is a small size. In this paper the method of mathematic simulation is applied for the investigation of one-effect evaporator with an external heating chamber. Detailed modelling is quite difficult because the phase equilibrium dynamics of the evaporation process is not described. Moreover, there is a relationship with the other process units. The results proved that the study subject is a MIMO plant, nonlinear over separate control channels and not selfbalancing. Adequacy was tested using the experimental data obtained at the laboratory evaporation unit.
Evaluation of Model Recognition for Grammar-Based Automatic 3d Building Model Reconstruction
NASA Astrophysics Data System (ADS)
Yu, Qian; Helmholz, Petra; Belton, David
2016-06-01
In recent years, 3D city models are in high demand by many public and private organisations, and the steadily growing capacity in both quality and quantity are increasing demand. The quality evaluation of these 3D models is a relevant issue both from the scientific and practical points of view. In this paper, we present a method for the quality evaluation of 3D building models which are reconstructed automatically from terrestrial laser scanning (TLS) data based on an attributed building grammar. The entire evaluation process has been performed in all the three dimensions in terms of completeness and correctness of the reconstruction. Six quality measures are introduced to apply on four datasets of reconstructed building models in order to describe the quality of the automatic reconstruction, and also are assessed on their validity from the evaluation point of view.
Verhaart, René F; Fortunati, Valerio; Verduijn, Gerda M; van Walsum, Theo; Veenland, Jifke F; Paulides, Margarethus M
2014-04-01
Clinical trials have shown that hyperthermia, as adjuvant to radiotherapy and/or chemotherapy, improves treatment of patients with locally advanced or recurrent head and neck (H&N) carcinoma. Hyperthermia treatment planning (HTP) guided H&N hyperthermia is being investigated, which requires patient specific 3D patient models derived from Computed Tomography (CT)-images. To decide whether a recently developed automatic-segmentation algorithm can be introduced in the clinic, we compared the impact of manual- and automatic normal-tissue-segmentation variations on HTP quality. CT images of seven patients were segmented automatically and manually by four observers, to study inter-observer and intra-observer geometrical variation. To determine the impact of this variation on HTP quality, HTP was performed using the automatic and manual segmentation of each observer, for each patient. This impact was compared to other sources of patient model uncertainties, i.e. varying gridsizes and dielectric tissue properties. Despite geometrical variations, manual and automatic generated 3D patient models resulted in an equal, i.e. 1%, variation in HTP quality. This variation was minor with respect to the total of other sources of patient model uncertainties, i.e. 11.7%. Automatically generated 3D patient models can be introduced in the clinic for H&N HTP. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Study of the time and effort signal in cutting operations
NASA Astrophysics Data System (ADS)
Grosset, E.; Maillard, A.; Bouhelier, C.; Gasnier, J.
1990-02-01
Perception and treatment of an effort signal by computer methods is discussed. An automatic control system used to measure the wear of machine tools and carry out quality control throughout the cutting process is described. The testing system is used to evaluate the performance of tools which have been vacuum plated. The system is used as part of the BRITE study, the goal of which is to develop an expert system for measuring the wear of tools used during drilling and perforation operations.
Zhang, Jing; Lipp, Ottmar V; Hu, Ping
2017-01-01
The current study investigated the interactive effects of individual differences in automatic emotion regulation (AER) and primed emotion regulation strategy on skin conductance level (SCL) and heart rate during provoked anger. The study was a 2 × 2 [AER tendency (expression vs. control) × priming (expression vs. control)] between subject design. Participants were assigned to two groups according to their performance on an emotion regulation-IAT (differentiating automatic emotion control tendency and automatic emotion expression tendency). Then participants of the two groups were randomly assigned to two emotion regulation priming conditions (emotion control priming or emotion expression priming). Anger was provoked by blaming participants for slow performance during a subsequent backward subtraction task. In anger provocation, SCL of individuals with automatic emotion control tendencies in the control priming condition was lower than of those with automatic emotion control tendencies in the expression priming condition. However, SCL of individuals with automatic emotion expression tendencies did no differ in the automatic emotion control priming or the automatic emotion expression priming condition. Heart rate during anger provocation was higher in individuals with automatic emotion expression tendencies than in individuals with automatic emotion control tendencies regardless of priming condition. This pattern indicates an interactive effect of individual differences in AER and emotion regulation priming on SCL, which is an index of emotional arousal. Heart rate was only sensitive to the individual differences in AER, and did not reflect this interaction. This finding has implications for clinical studies of the use of emotion regulation strategy training suggesting that different practices are optimal for individuals who differ in AER tendencies.
NASA Astrophysics Data System (ADS)
Zhao, Yan; Yang, Zijiang; Gao, Song; Liu, Jinbiao
2018-02-01
Automatic generation control(AGC) is a key technology to maintain real time power generation and load balance, and to ensure the quality of power supply. Power grids require each power generation unit to have a satisfactory AGC performance, being specified in two detailed rules. The two rules provide a set of indices to measure the AGC performance of power generation unit. However, the commonly-used method to calculate these indices is based on particular data samples from AGC responses and will lead to incorrect results in practice. This paper proposes a new method to estimate the AGC performance indices via system identification techniques. In addition, a nonlinear regression model between performance indices and load command is built in order to predict the AGC performance indices. The effectiveness of the proposed method is validated through industrial case studies.
Evaluation of automatic image quality assessment in chest CT - A human cadaver study.
Franck, Caro; De Crop, An; De Roo, Bieke; Smeets, Peter; Vergauwen, Merel; Dewaele, Tom; Van Borsel, Mathias; Achten, Eric; Van Hoof, Tom; Bacher, Klaus
2017-04-01
The evaluation of clinical image quality (IQ) is important to optimize CT protocols and to keep patient doses as low as reasonably achievable. Considering the significant amount of effort needed for human observer studies, automatic IQ tools are a promising alternative. The purpose of this study was to evaluate automatic IQ assessment in chest CT using Thiel embalmed cadavers. Chest CT's of Thiel embalmed cadavers were acquired at different exposures. Clinical IQ was determined by performing a visual grading analysis. Physical-technical IQ (noise, contrast-to-noise and contrast-detail) was assessed in a Catphan phantom. Soft and sharp reconstructions were made with filtered back projection and two strengths of iterative reconstruction. In addition to the classical IQ metrics, an automatic algorithm was used to calculate image quality scores (IQs). To be able to compare datasets reconstructed with different kernels, the IQs values were normalized. Good correlations were found between IQs and the measured physical-technical image quality: noise (ρ=-1.00), contrast-to-noise (ρ=1.00) and contrast-detail (ρ=0.96). The correlation coefficients between IQs and the observed clinical image quality of soft and sharp reconstructions were 0.88 and 0.93, respectively. The automatic scoring algorithm is a promising tool for the evaluation of thoracic CT scans in daily clinical practice. It allows monitoring of the image quality of a chest protocol over time, without human intervention. Different reconstruction kernels can be compared after normalization of the IQs. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Valderrama, Joaquin T; de la Torre, Angel; Alvarez, Isaac; Segura, Jose Carlos; Thornton, A Roger D; Sainz, Manuel; Vargas, Jose Luis
2014-05-01
The recording of the auditory brainstem response (ABR) is used worldwide for hearing screening purposes. In this process, a precise estimation of the most relevant components is essential for an accurate interpretation of these signals. This evaluation is usually carried out subjectively by an audiologist. However, the use of automatic methods for this purpose is being encouraged nowadays in order to reduce human evaluation biases and ensure uniformity among test conditions, patients, and screening personnel. This article describes a new method that performs automatic quality assessment and identification of the peaks, the fitted parametric peaks (FPP). This method is based on the use of synthesized peaks that are adjusted to the ABR response. The FPP is validated, on one hand, by an analysis of amplitudes and latencies measured manually by an audiologist and automatically by the FPP method in ABR signals recorded at different stimulation rates; and on the other hand, contrasting the performance of the FPP method with the automatic evaluation techniques based on the correlation coefficient, FSP, and cross correlation with a predefined template waveform by comparing the automatic evaluations of the quality of these methods with subjective evaluations provided by five experienced evaluators on a set of ABR signals of different quality. The results of this study suggest (a) that the FPP method can be used to provide an accurate parameterization of the peaks in terms of amplitude, latency, and width, and (b) that the FPP remains as the method that best approaches the averaged subjective quality evaluation, as well as provides the best results in terms of sensitivity and specificity in ABR signals validation. The significance of these findings and the clinical value of the FPP method are highlighted on this paper. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Presley, Todd K.; Jamison, Marcael T.J.
2009-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. The program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream, and to assess the effects from the H-1 storm drain on Manoa Stream. For this program, rainfall data were collected at three stations, continuous discharge data at five stations, and water-quality data at six stations, which include the five continuous discharge stations. This report summarizes rainfall, discharge, and water-quality data collected between July 1, 2008, and June 30, 2009. Within the Halawa Stream drainage area, three storms (October 25 and December 11, 2008, and February 3, 2009) were sampled during July 1, 2008, to June 30, 2009. A total of 43 environmental samples were collected during these three storms. During the storm of October 25, 2009, 31 samples were collected and analyzed individually for metals only. The other 12 samples from the other two storms were analyzed for some or all of the following analytes: total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, and zinc). Additionally, grab samples were analyzed for some or all of the following analytes: oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Some grab and composite samples were analyzed for only a partial list of these analytes, either because samples could not be delivered to the laboratory in a timely manner, or an insufficient volume of sample was collected by the automatic samplers. Two quality-assurance/quality-control samples were collected after cleaning automatic sampler lines to verify that the sampling lines were not contaminated. Four environmental samples were collected at the H-1 Storm Drain during July 1, 2008, to June 30, 2009. An oil and grease sample and a composite sample were collected during the storm on November 15, 2008, and two composite samples were collected during the January 11, 2009, storm. All samples at this site were collected using an automatic sampler. Samples were analyzed for some or all of the following analytes: total suspended solids, nutrients, oil and grease, total petroleum hydrocarbons, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). One qualityassurance/quality-control sample was collected after cleaning automatic sampler lines to verify that the sampling lines were not contaminated. During the storm of January 11, 2009, the two composite samples collected at H-1 Storm Drain were collected about three hours apart. Higher constituent concentrations were detected in the first 2 composite sample relative to the second composite sample, although the average discharge was higher during the period when the second sample was collected.
49 CFR 236.552 - Insulation resistance; requirement.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic... control system, or automatic train stop system shall be not less than one megohm, and that of an... system, automatic train control system, or automatic train stop system, and 20,000 ohms for an...
NASA Astrophysics Data System (ADS)
Tellaeche, A.; Arana, R.; Ibarguren, A.; Martínez-Otzeta, J. M.
The exhaustive quality control is becoming very important in the world's globalized market. One of these examples where quality control becomes critical is the percussion cap mass production. These elements must achieve a minimum tolerance deviation in their fabrication. This paper outlines a machine vision development using a 3D camera for the inspection of the whole production of percussion caps. This system presents multiple problems, such as metallic reflections in the percussion caps, high speed movement of the system and mechanical errors and irregularities in percussion cap placement. Due to these problems, it is impossible to solve the problem by traditional image processing methods, and hence, machine learning algorithms have been tested to provide a feasible classification of the possible errors present in the percussion caps.
Feasibility Study on Fully Automatic High Quality Translation: Volume II. Final Technical Report.
ERIC Educational Resources Information Center
Lehmann, Winifred P.; Stachowitz, Rolf
This second volume of a two-volume report on a fully automatic high quality translation (FAHQT) contains relevant papers contributed by specialists on the topic of machine translation. The papers presented here cover such topics as syntactical analysis in transformational grammar and in machine translation, lexical features in translation and…
CALL FOR PAPERS: 13th International Conference on Force and Mass Measurement
NASA Astrophysics Data System (ADS)
1992-01-01
10 14 May 1993, Helsinki Fair Centre, Finland Scope of the Conference The Conference reports and reviews the state of the art and future trends in force and mass measurements in science and industry. Emphasis is on the applications of new methods, current problems in calibration and quality control, as well as on advancements in new sensor technologies and industrial application of force and mass measurements. Main Themes and Topics 1. The state of the art and development trends in force and mass measurements Development and stability of high level mass standards Mass comparators and force standard machine New research topics in mass and force 2. Calibration and quality control Calibration methods Estimation of uncertainties and classification of accuracies Relations between calibration, testing and quality control Requirements for quality control Verification of weighing instruments and their main devices 3. Application of force and mass measurements Automatic weighing Mass flow measurements Quality control in process industry Sensor technologies Practical applications Special applications in industry, trade, etc. Deadline for submission of abstracts: 30 June 1992. For further information please contact: Finnish Society of Automation, Asemapäällikönkatu 12C, SF-00520 HELSINKI, Finland Phone: Int. +3580 1461 644, Fax: Int. +3580 1461 650
49 CFR 236.506 - Release of brakes after automatic application.
Code of Federal Regulations, 2010 CFR
2010-10-01
... INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.506 Release of brakes after automatic application. The automatic train stop or train control apparatus shall prevent release of the...
49 CFR 236.506 - Release of brakes after automatic application.
Code of Federal Regulations, 2011 CFR
2011-10-01
... INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.506 Release of brakes after automatic application. The automatic train stop or train control apparatus shall prevent release of the...
The Use of Automatic Indexing for Authority Control.
ERIC Educational Resources Information Center
Dillon, Martin; And Others
1981-01-01
Uses an experimental system for authority control on a collection of bibliographic records to demonstrate the resemblance between thesaurus-based automatic indexing and automatic authority control. Details of the automatic indexing system are given, results discussed, and the benefits of the resemblance examined. Included are a rules appendix and…
Chiba, M
2000-10-01
Further business improvement is requested due to finance-based fluctuation and the influence of the revision in the medical treatment law. Therefore, new laboratories are needed. To achieving this in our hospital, economic efficiency is being pursued. The first issue is the use of space, the second issue is labor-saving. The third issue is the simplification of business procedures. There is individual quality control by the zonal verification method that we developed, as well as the quality control of the batch method using controlled substances. The four issue is cost control. By controlling the delivery and use of reagents and materials including the term of validity control, we made an effort to abolition defective stock. The fifth issue is correspondence to circulation style society. The disposal of laboratory garbage is a major issue. We controlled garbage that occurs unnecessarily. Furthermore, we are improving the demand for reagents that exceeds the specification and use reagent containers.
Pushing typists back on the learning curve: revealing chunking in skilled typewriting.
Yamaguchi, Motonori; Logan, Gordon D
2014-04-01
Theories of skilled performance propose that highly trained skills involve hierarchically structured control processes. The present study examined and demonstrated hierarchical control at several levels of processing in skilled typewriting. In the first two experiments, we scrambled the order of letters in words to prevent skilled typists from chunking letters, and compared typing words and scrambled words. Experiment 1 manipulated stimulus quality to reveal chunking in perception, and Experiment 2 manipulated concurrent memory load to reveal chunking in short-term memory (STM). Both experiments manipulated the number of letters in words and nonwords to reveal chunking in motor planning. In the next two experiments, we degraded typing skill by altering the usual haptic feedback by using a laser-projection keyboard, so that typists had to monitor keystrokes. Neither the number of motor chunks (Experiment 3) nor the number of STM items (Experiment 4) was influenced by the manipulation. The results indicate that the utilization of hierarchical control depends on whether the input allows chunking but not on whether the output is generated automatically. We consider the role of automaticity in hierarchical control of skilled performance.
Page, Jason S.; Bogdanov, Bogdan; Vilkov, Andrey N.; Prior, David C.; Buschbach, Michael A.; Tang, Keqi; Smith, Richard D.
2007-01-01
We report on the use of a jet disrupter electrode in an electrodynamic ion funnel as an electronic valve to regulate the intensity of the ion beam transmitted through the interface of a mass spectrometer in order to perform automatic gain control (AGC). The ion flux is determined by either directly detecting the ion current on the conductance limiting orifice of the ion funnel or using a short mass spectrometry acquisition. Based upon the ion flux intensity, the voltage of the jet disrupter is adjusted to alter the transmission efficiency of the ion funnel to provide a desired ion population to the mass analyzer. Ion beam regulation by an ion funnel is shown to provide control to within a few percent of a targeted ion intensity or abundance. The utility of ion funnel AGC was evaluated using a protein tryptic digest analyzed with liquid chromatography Fourier transform ion cyclotron resonance (LC-FTICR) mass spectrometry. The ion population in the ICR cell was accurately controlled to selected levels, which improved data quality and provided better mass measurement accuracy. PMID:15694774
[Automatic adjustment control system for DC glow discharge plasma source].
Wan, Zhen-zhen; Wang, Yong-qing; Li, Xiao-jia; Wang, Hai-zhou; Shi, Ning
2011-03-01
There are three important parameters in the DC glow discharge process, the discharge current, discharge voltage and argon pressure in discharge source. These parameters influence each other during glow discharge process. This paper presents an automatic control system for DC glow discharge plasma source. This system collects and controls discharge voltage automatically by adjusting discharge source pressure while the discharge current is constant in the glow discharge process. The design concept, circuit principle and control program of this automatic control system are described. The accuracy is improved by this automatic control system with the method of reducing the complex operations and manual control errors. This system enhances the control accuracy of glow discharge voltage, and reduces the time to reach discharge voltage stability. The glow discharge voltage stability test results with automatic control system are provided as well, the accuracy with automatic control system is better than 1% FS which is improved from 4% FS by manual control. Time to reach discharge voltage stability has been shortened to within 30 s by automatic control from more than 90 s by manual control. Standard samples like middle-low alloy steel and tin bronze have been tested by this automatic control system. The concentration analysis precision has been significantly improved. The RSDs of all the test result are better than 3.5%. In middle-low alloy steel standard sample, the RSD range of concentration test result of Ti, Co and Mn elements is reduced from 3.0%-4.3% by manual control to 1.7%-2.4% by automatic control, and that for S and Mo is also reduced from 5.2%-5.9% to 3.3%-3.5%. In tin bronze standard sample, the RSD range of Sn, Zn and Al elements is reduced from 2.6%-4.4% to 1.0%-2.4%, and that for Si, Ni and Fe is reduced from 6.6%-13.9% to 2.6%-3.5%. The test data is also shown in this paper.
Dosimetry and image quality assessment in a direct radiography system
Oliveira, Bruno Beraldo; de Oliveira, Marcio Alves; Paixão, Lucas; Teixeira, Maria Helena Araújo; Nogueira, Maria do Socorro
2014-01-01
Objective To evaluate the mean glandular dose with a solid state detector and the image quality in a direct radiography system, utilizing phantoms. Materials and Methods Irradiations were performed with automatic exposure control and polymethyl methacrylate slabs with different thicknesses to calculate glandular dose values. The image quality was evaluated by means of the structures visualized on the images of the phantoms. Results Considering the uncertainty of the measurements, the mean glandular dose results are in agreement with the values provided by the equipment and with internationally adopted reference levels. Results obtained from images of the phantoms were in agreement with the reference values. Conclusion The present study contributes to verify the equipment conformity as regards dose values and image quality. PMID:25741119
GREENE, BETH G.; LOGAN, JOHN S.; PISONI, DAVID B.
2012-01-01
We present the results of studies designed to measure the segmental intelligibility of eight text-to-speech systems and a natural speech control, using the Modified Rhyme Test (MRT). Results indicated that the voices tested could be grouped into four categories: natural speech, high-quality synthetic speech, moderate-quality synthetic speech, and low-quality synthetic speech. The overall performance of the best synthesis system, DECtalk-Paul, was equivalent to natural speech only in terms of performance on initial consonants. The findings are discussed in terms of recent work investigating the perception of synthetic speech under more severe conditions. Suggestions for future research on improving the quality of synthetic speech are also considered. PMID:23225916
Minimum airflow reset of single-duct VAV terminal boxes
NASA Astrophysics Data System (ADS)
Cho, Young-Hum
Single duct Variable Air Volume (VAV) systems are currently the most widely used type of HVAC system in the United States. When installing such a system, it is critical to determine the minimum airflow set point of the terminal box, as an optimally selected set point will improve the level of thermal comfort and indoor air quality (IAQ) while at the same time lower overall energy costs. In principle, this minimum rate should be calculated according to the minimum ventilation requirement based on ASHRAE standard 62.1 and maximum heating load of the zone. Several factors must be carefully considered when calculating this minimum rate. Terminal boxes with conventional control sequences may result in occupant discomfort and energy waste. If the minimum rate of airflow is set too high, the AHUs will consume excess fan power, and the terminal boxes may cause significant simultaneous room heating and cooling. At the same time, a rate that is too low will result in poor air circulation and indoor air quality in the air-conditioned space. Currently, many scholars are investigating how to change the algorithm of the advanced VAV terminal box controller without retrofitting. Some of these controllers have been found to effectively improve thermal comfort, indoor air quality, and energy efficiency. However, minimum airflow set points have not yet been identified, nor has controller performance been verified in confirmed studies. In this study, control algorithms were developed that automatically identify and reset terminal box minimum airflow set points, thereby improving indoor air quality and thermal comfort levels, and reducing the overall rate of energy consumption. A theoretical analysis of the optimal minimum airflow and discharge air temperature was performed to identify the potential energy benefits of resetting the terminal box minimum airflow set points. Applicable control algorithms for calculating the ideal values for the minimum airflow reset were developed and applied to actual systems for performance validation. The results of the theoretical analysis, numeric simulations, and experiments show that the optimal control algorithms can automatically identify the minimum rate of heating airflow under actual working conditions. Improved control helps to stabilize room air temperatures. The vertical difference in the room air temperature was lower than the comfort value. Measurements of room CO2 levels indicate that when the minimum airflow set point was reduced it did not adversely affect the indoor air quality. According to the measured energy results, optimal control algorithms give a lower rate of reheating energy consumption than conventional controls.
75 FR 3959 - Fifth Meeting-RTCA Special Committee 220: Automatic Flight Guidance and Control
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-25
... 220: Automatic Flight Guidance and Control AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 220: Automatic Flight Guidance and Control meeting. SUMMARY: The FAA is issuing this notice to advise the public of a meeting of RTCA Special Committee 220: Automatic Flight...
75 FR 15770 - Sixth Meeting-RTCA Special Committee 220: Automatic Flight Guidance and Control
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-30
... 220: Automatic Flight Guidance and Control AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 220: Automatic Flight Guidance and Control meeting. SUMMARY: The FAA is issuing this notice to advise the public of a meeting of RTCA Special Committee 220: Automatic Flight...
76 FR 22163 - Tenth Meeting: RTCA Special Committee 220: Automatic Flight Guidance and Control
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-20
... 220: Automatic Flight Guidance and Control AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 220 meeting: Automatic Flight Guidance and Control. SUMMARY: The FAA is issuing this notice to advise the public of a meeting of RTCA Special Committee 220: Automatic Flight...
Code of Federal Regulations, 2011 CFR
2011-10-01
... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.502 Automatic brake application, initiation by restrictive block conditions stopping distance in advance. An automatic train-stop or train-control system shall operate to...
Xu, Yaoshan; Li, Yongjuan; Ding, Weidong; Lu, Fan
2014-01-01
This study explores the precursors of employees' safety behaviors based on a dual-process model, which suggests that human behaviors are determined by both controlled and automatic cognitive processes. Employees' responses to a self-reported survey on safety attitudes capture their controlled cognitive process, while the automatic association concerning safety measured by an Implicit Association Test (IAT) reflects employees' automatic cognitive processes about safety. In addition, this study investigates the moderating effects of inhibition on the relationship between self-reported safety attitude and safety behavior, and that between automatic associations towards safety and safety behavior. The results suggest significant main effects of self-reported safety attitude and automatic association on safety behaviors. Further, the interaction between self-reported safety attitude and inhibition and that between automatic association and inhibition each predict unique variances in safety behavior. Specifically, the safety behaviors of employees with lower level of inhibitory control are influenced more by automatic association, whereas those of employees with higher level of inhibitory control are guided more by self-reported safety attitudes. These results suggest that safety behavior is the joint outcome of both controlled and automatic cognitive processes, and the relative importance of these cognitive processes depends on employees' individual differences in inhibitory control. The implications of these findings for theoretical and practical issues are discussed at the end.
Xu, Yaoshan; Li, Yongjuan; Ding, Weidong; Lu, Fan
2014-01-01
This study explores the precursors of employees' safety behaviors based on a dual-process model, which suggests that human behaviors are determined by both controlled and automatic cognitive processes. Employees' responses to a self-reported survey on safety attitudes capture their controlled cognitive process, while the automatic association concerning safety measured by an Implicit Association Test (IAT) reflects employees' automatic cognitive processes about safety. In addition, this study investigates the moderating effects of inhibition on the relationship between self-reported safety attitude and safety behavior, and that between automatic associations towards safety and safety behavior. The results suggest significant main effects of self-reported safety attitude and automatic association on safety behaviors. Further, the interaction between self-reported safety attitude and inhibition and that between automatic association and inhibition each predict unique variances in safety behavior. Specifically, the safety behaviors of employees with lower level of inhibitory control are influenced more by automatic association, whereas those of employees with higher level of inhibitory control are guided more by self-reported safety attitudes. These results suggest that safety behavior is the joint outcome of both controlled and automatic cognitive processes, and the relative importance of these cognitive processes depends on employees' individual differences in inhibitory control. The implications of these findings for theoretical and practical issues are discussed at the end. PMID:24520338
Mobile sailing robot for automatic estimation of fish density and monitoring water quality
2013-01-01
Introduction The paper presents the methodology and the algorithm developed to analyze sonar images focused on fish detection in small water bodies and measurement of their parameters: volume, depth and the GPS location. The final results are stored in a table and can be exported to any numerical environment for further analysis. Material and method The measurement method for estimating the number of fish using the automatic robot is based on a sequential calculation of the number of occurrences of fish on the set trajectory. The data analysis from the sonar concerned automatic recognition of fish using the methods of image analysis and processing. Results Image analysis algorithm, a mobile robot together with its control in the 2.4 GHz band and full cryptographic communication with the data archiving station was developed as part of this study. For the three model fish ponds where verification of fish catches was carried out (548, 171 and 226 individuals), the measurement error for the described method was not exceeded 8%. Summary Created robot together with the developed software has features for remote work also in the variety of harsh weather and environmental conditions, is fully automated and can be remotely controlled using Internet. Designed system enables fish spatial location (GPS coordinates and the depth). The purpose of the robot is a non-invasive measurement of the number of fish in water reservoirs and a measurement of the quality of drinking water consumed by humans, especially in situations where local sources of pollution could have a significant impact on the quality of water collected for water treatment for people and when getting to these places is difficult. The systematically used robot equipped with the appropriate sensors, can be part of early warning system against the pollution of water used by humans (drinking water, natural swimming pools) which can be dangerous for their health. PMID:23815984
Mobile sailing robot for automatic estimation of fish density and monitoring water quality.
Koprowski, Robert; Wróbel, Zygmunt; Kleszcz, Agnieszka; Wilczyński, Sławomir; Woźnica, Andrzej; Łozowski, Bartosz; Pilarczyk, Maciej; Karczewski, Jerzy; Migula, Paweł
2013-07-01
The paper presents the methodology and the algorithm developed to analyze sonar images focused on fish detection in small water bodies and measurement of their parameters: volume, depth and the GPS location. The final results are stored in a table and can be exported to any numerical environment for further analysis. The measurement method for estimating the number of fish using the automatic robot is based on a sequential calculation of the number of occurrences of fish on the set trajectory. The data analysis from the sonar concerned automatic recognition of fish using the methods of image analysis and processing. Image analysis algorithm, a mobile robot together with its control in the 2.4 GHz band and full cryptographic communication with the data archiving station was developed as part of this study. For the three model fish ponds where verification of fish catches was carried out (548, 171 and 226 individuals), the measurement error for the described method was not exceeded 8%. Created robot together with the developed software has features for remote work also in the variety of harsh weather and environmental conditions, is fully automated and can be remotely controlled using Internet. Designed system enables fish spatial location (GPS coordinates and the depth). The purpose of the robot is a non-invasive measurement of the number of fish in water reservoirs and a measurement of the quality of drinking water consumed by humans, especially in situations where local sources of pollution could have a significant impact on the quality of water collected for water treatment for people and when getting to these places is difficult. The systematically used robot equipped with the appropriate sensors, can be part of early warning system against the pollution of water used by humans (drinking water, natural swimming pools) which can be dangerous for their health.
Bujila, Robert; Poludniowski, Gavin; Fransson, Annette
2015-01-01
The purpose of this study was to develop a method of performing routine periodical quality controls (QC) of CT systems by automatically analyzing key performance indicators (KPIs), obtainable from images of manufacturers' quality assurance (QA) phantoms. A KPI pertains to a measurable or determinable QC parameter that is influenced by other underlying fundamental QC parameters. The established KPIs are based on relationships between existing QC parameters used in the annual testing program of CT scanners at the Karolinska University Hospital in Stockholm, Sweden. The KPIs include positioning, image noise, uniformity, homogeneity, the CT number of water, and the CT number of air. An application (MonitorCT) was developed to automatically evaluate phantom images in terms of the established KPIs. The developed methodology has been used for two years in clinical routine, where CT technologists perform daily scans of the manufacturer's QA phantom and automatically send the images to MonitorCT for KPI evaluation. In the cases where results were out of tolerance, actions could be initiated in less than 10 min. 900 QC scans from two CT scanners have been collected and analyzed over the two‐year period that MonitorCT has been active. Two types of errors have been registered in this period: a ring artifact was discovered with the image noise test, and a calibration error was detected multiple times with the CT number test. In both cases, results were outside the tolerances defined for MonitorCT, as well as by the vendor. Automated monitoring of KPIs is a powerful tool that can be used to supplement established QC methodologies. Medical physicists and other professionals concerned with the performance of a CT system will, using such methods, have access to comprehensive data on the current and historical (trend) status of the system such that swift actions can be taken in order to ensure the quality of the CT examinations, patient safety, and minimal disruption of service PACS numbers: 87.57.C‐, 87.57.N‐, 87.57.Q‐ PMID:26219012
Automatic color preference correction for color reproduction
NASA Astrophysics Data System (ADS)
Tsukada, Masato; Funayama, Chisato; Tajima, Johji
2000-12-01
The reproduction of natural objects in color images has attracted a great deal of attention. Reproduction more pleasing colors of natural objects is one of the methods available to improve image quality. We developed an automatic color correction method to maintain preferred color reproduction for three significant categories: facial skin color, green grass and blue sky. In this method, a representative color in an object area to be corrected is automatically extracted from an input image, and a set of color correction parameters is selected depending on the representative color. The improvement in image quality for reproductions of natural image was more than 93 percent in subjective experiments. These results show the usefulness of our automatic color correction method for the reproduction of preferred colors.
ERIC Educational Resources Information Center
Crossley, Scott A.; Allen, Laura K.; Snow, Erica L.; McNamara, Danielle S.
2016-01-01
This study investigates a novel approach to automatically assessing essay quality that combines natural language processing approaches that assess text features with approaches that assess individual differences in writers such as demographic information, standardized test scores, and survey results. The results demonstrate that combining text…
Feasibility Study on Fully Automatic High Quality Translation: Volume I. Final Technical Report.
ERIC Educational Resources Information Center
Lehmann, Winifred P.; Stachowitz, Rolf
The object of this theoretical inquiry is to examine the controversial issue of a fully automatic high quality translation (FAHQT) in the light of past and projected advances in linguistic theory and hardware/software capability. This first volume of a two-volume report discusses the requirements of translation and aspects of human and machine…
[Effect of manual cleaning and machine cleaning for dental handpiece].
Zhou, Xiaoli; Huang, Hao; He, Xiaoyan; Chen, Hui; Zhou, Xiaoying
2013-08-01
Comparing the dental handpiece' s cleaning effect between manual cleaning and machine cleaning. Eighty same contaminated dental handpieces were randomly divided into experimental group and control group, each group contains 40 pieces. The experimental group was treated by full automatic washing machine, and the control group was cleaned manually. The cleaning method was conducted according to the operations process standard, then ATP bioluminescence was used to test the cleaning results. Average relative light units (RLU) by ATP bioluminescence detection were as follows: Experimental group was 9, control group was 41. The two groups were less than the recommended RLU value provided by the instrument manufacturer (RLU < or = 45). There was significant difference between the two groups (P < 0.05). The cleaning quality of the experimental group was better than that of control group. It is recommended that the central sterile supply department should clean dental handpieces by machine to ensure the cleaning effect and maintain the quality.
[Advances in research on automatic exposure control of mammography system].
Wang, Guoyi; Ye, Chengfu; Wu, Haiming; Wang, Tainfu; Zhang, Hong
2014-12-01
Mammography imaging is one of the most demanding imaging modalities from the point of view of the bal- ance between image quality (the visibility of small size and/or low contrast structures) and dose (screening of many asymptomatic people). Therefore, since the introduction of the first dedicated mammographic units, many efforts have been directed to seek the best possible image quality while minimizing patient dose. The performance of auto- matic exposure control (AEC) is the manifestation of this demand. The theory of AEC includes exposure detection and optimization and also involves some accomplished methodology. This review presents the development and present situa- tion of spectrum optimization, detector evolution, and the way how to accomplish and evaluate AEC methods.
Theory research of seam recognition and welding torch pose control based on machine vision
NASA Astrophysics Data System (ADS)
Long, Qiang; Zhai, Peng; Liu, Miao; He, Kai; Wang, Chunyang
2017-03-01
At present, the automation requirement of the welding become higher, so a method of the welding information extraction by vision sensor is proposed in this paper, and the simulation with the MATLAB has been conducted. Besides, in order to improve the quality of robot automatic welding, an information retrieval method for welding torch pose control by visual sensor is attempted. Considering the demands of welding technology and engineering habits, the relative coordinate systems and variables are strictly defined, and established the mathematical model of the welding pose, and verified its feasibility by using the MATLAB simulation in the paper, these works lay a foundation for the development of welding off-line programming system with high precision and quality.
X-29A flight control system performance during flight test
NASA Technical Reports Server (NTRS)
Chin, J.; Chacon, V.; Gera, J.
1987-01-01
An account is given of flight control system performance results for the X-29A forward-swept wing 'Advanced Technology Demonstrator' fighter aircraft, with attention to its software and hardware components' achievement of the requisite levels of system stability and desirable aircraft handling qualities. The Automatic Camber Control Logic is found to be well integrated with the stability loop of the aircraft. A number of flight test support software programs developed by NASA facilitated monitoring of the X-29A's stability in real time, and allowed the test team to clear the envelope with confidence.
NASA Astrophysics Data System (ADS)
Brook, A.; Cristofani, E.; Vandewal, M.; Matheis, C.; Jonuscheit, J.; Beigang, R.
2012-05-01
The present study proposes a fully integrated, semi-automatic and near real-time mode-operated image processing methodology developed for Frequency-Modulated Continuous-Wave (FMCW) THz images with the center frequencies around: 100 GHz and 300 GHz. The quality control of aeronautics composite multi-layered materials and structures using Non-Destructive Testing is the main focus of this work. Image processing is applied on the 3-D images to extract useful information. The data is processed by extracting areas of interest. The detected areas are subjected to image analysis for more particular investigation managed by a spatial model. Finally, the post-processing stage examines and evaluates the spatial accuracy of the extracted information.
46 CFR 62.25-15 - Safety control systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
....35-50. Note: Safety control systems include automatic and manual safety trip controls and automatic... engines. (e) Automatic safety trip control systems must— (1) Be provided where there is an immediate... 46 Shipping 2 2011-10-01 2011-10-01 false Safety control systems. 62.25-15 Section 62.25-15...
Algorithm for automatic forced spirometry quality assessment: technological developments.
Melia, Umberto; Burgos, Felip; Vallverdú, Montserrat; Velickovski, Filip; Lluch-Ariet, Magí; Roca, Josep; Caminal, Pere
2014-01-01
We hypothesized that the implementation of automatic real-time assessment of quality of forced spirometry (FS) may significantly enhance the potential for extensive deployment of a FS program in the community. Recent studies have demonstrated that the application of quality criteria defined by the ATS/ERS (American Thoracic Society/European Respiratory Society) in commercially available equipment with automatic quality assessment can be markedly improved. To this end, an algorithm for assessing quality of FS automatically was reported. The current research describes the mathematical developments of the algorithm. An innovative analysis of the shape of the spirometric curve, adding 23 new metrics to the traditional 4 recommended by ATS/ERS, was done. The algorithm was created through a two-step iterative process including: (1) an initial version using the standard FS curves recommended by the ATS; and, (2) a refined version using curves from patients. In each of these steps the results were assessed against one expert's opinion. Finally, an independent set of FS curves from 291 patients was used for validation purposes. The novel mathematical approach to characterize the FS curves led to appropriate FS classification with high specificity (95%) and sensitivity (96%). The results constitute the basis for a successful transfer of FS testing to non-specialized professionals in the community.
Code of Federal Regulations, 2013 CFR
2013-10-01
... control means a function of an automatic control system to restrict operation to a specified operating... automatic or manual control. Safety trip control system means a manually or automatically operated system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Terms Used...
Code of Federal Regulations, 2010 CFR
2010-10-01
... control means a function of an automatic control system to restrict operation to a specified operating... automatic or manual control. Safety trip control system means a manually or automatically operated system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Terms Used...
Code of Federal Regulations, 2012 CFR
2012-10-01
... control means a function of an automatic control system to restrict operation to a specified operating... automatic or manual control. Safety trip control system means a manually or automatically operated system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Terms Used...
Code of Federal Regulations, 2014 CFR
2014-10-01
... control means a function of an automatic control system to restrict operation to a specified operating... automatic or manual control. Safety trip control system means a manually or automatically operated system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Terms Used...
Code of Federal Regulations, 2011 CFR
2011-10-01
... control means a function of an automatic control system to restrict operation to a specified operating... automatic or manual control. Safety trip control system means a manually or automatically operated system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Terms Used...
NASA Astrophysics Data System (ADS)
Kokubun, Y.; Washizuka, S.; Ushizawa, J.; Watanabe, M.; Fukuda, T.
1982-11-01
The properties of GaP single crystals grown by an automatically diameter controlled liquid encapsulated Czochralski technique using a computer have been studied. A dislocation density less than 5×104 cm-2 has been observed for crystal grown in a temperature gradient lower than 70 °C/cm near the solid-liquid interface. Crystals have about 10% higher electron mobility than that of commercially available coracle controlled crystals and have 0.2˜0.5 compensation ratios. Yellow light emitting diodes using computer controlled (100) substrates have shown extremely high external quantum efficiency of 0.3%.
Refining Automatically Extracted Knowledge Bases Using Crowdsourcing.
Li, Chunhua; Zhao, Pengpeng; Sheng, Victor S; Xian, Xuefeng; Wu, Jian; Cui, Zhiming
2017-01-01
Machine-constructed knowledge bases often contain noisy and inaccurate facts. There exists significant work in developing automated algorithms for knowledge base refinement. Automated approaches improve the quality of knowledge bases but are far from perfect. In this paper, we leverage crowdsourcing to improve the quality of automatically extracted knowledge bases. As human labelling is costly, an important research challenge is how we can use limited human resources to maximize the quality improvement for a knowledge base. To address this problem, we first introduce a concept of semantic constraints that can be used to detect potential errors and do inference among candidate facts. Then, based on semantic constraints, we propose rank-based and graph-based algorithms for crowdsourced knowledge refining, which judiciously select the most beneficial candidate facts to conduct crowdsourcing and prune unnecessary questions. Our experiments show that our method improves the quality of knowledge bases significantly and outperforms state-of-the-art automatic methods under a reasonable crowdsourcing cost.
Assessing Walking Strategies Using Insole Pressure Sensors for Stroke Survivors.
Munoz-Organero, Mario; Parker, Jack; Powell, Lauren; Mawson, Susan
2016-10-01
Insole pressure sensors capture the different forces exercised over the different parts of the sole when performing tasks standing up such as walking. Using data analysis and machine learning techniques, common patterns and strategies from different users to achieve different tasks can be automatically extracted. In this paper, we present the results obtained for the automatic detection of different strategies used by stroke survivors when walking as integrated into an Information Communication Technology (ICT) enhanced Personalised Self-Management Rehabilitation System (PSMrS) for stroke rehabilitation. Fourteen stroke survivors and 10 healthy controls have participated in the experiment by walking six times a distance from chair to chair of approximately 10 m long. The Rivermead Mobility Index was used to assess the functional ability of each individual in the stroke survivor group. Several walking strategies are studied based on data gathered from insole pressure sensors and patterns found in stroke survivor patients are compared with average patterns found in healthy control users. A mechanism to automatically estimate a mobility index based on the similarity of the pressure patterns to a stereotyped stride is also used. Both data gathered from stroke survivors and healthy controls are used to evaluate the proposed mechanisms. The output of trained algorithms is applied to the PSMrS system to provide feedback on gait quality enabling stroke survivors to self-manage their rehabilitation.
Precision controllability of the YF-17 airplane
NASA Technical Reports Server (NTRS)
Sisk, T. R.; Mataeny, N. W.
1980-01-01
A flying qualities evaluation conducted on the YF-17 airplane permitted assessment of its precision controllability in the transonic flight regime over the allowable angle of attack range. The precision controllability (tailchase tracking) study was conducted in constant-g and windup turn tracking maneuvers with the command augmentation system (CAS) on, automatic maneuver flaps, and the caged pipper gunsight depressed 70 mils. This study showed that the YF-17 airplane tracks essentially as well at 7 g's to 8 g's as earlier fighters did at 4 g's to 5 g's before they encountered wing rock. The pilots considered the YF-17 airplane one of the best tracking airplanes they had flown. Wing rock at the higher angles of attack degraded tracking precision, and lack of control harmony made precision controllability more difficult. The revised automatic maneuver flap schedule incorporated in the airplane at the time of the tests did not appear to be optimum. The largest tracking errors and greatest pilot workload occurred at high normal load factors at low angles of attack. The pilots reported that the high-g maneuvers caused some tunnel vision and that they found it difficult to think clearly after repeated maneuvers.
Features and perspectives of automatized construction crane-manipulators
NASA Astrophysics Data System (ADS)
Stepanov, Mikhail A.; Ilukhin, Peter A.
2018-03-01
Modern construction industry still has a high percentage of manual labor, and the greatest prospects of improving the construction process are lying in the field of automatization. In this article automatized construction manipulator-cranes are being studied in order to achieve the most rational design scheme. This is done through formulating a list of general conditions necessary for such cranes and a set of specialized kinematical conditions. A variety of kinematical schemes is evaluated via these conditions, and some are taken for further dynamical analisys. The comparative dynamical analisys of taken schemes was made and the most rational scheme was defined. Therefore a basis for a more complex and practical research of manipulator-cranes design is given and ways to implement them on practical level can now be calculated properly. Also, the perspectives of implementation of automated control systems and informational networks on construction sites in order to boost the quality of construction works, safety of labour and ecological safety are shown.
Improvement of automatic control system for high-speed current collectors
NASA Astrophysics Data System (ADS)
Sidorov, O. A.; Goryunov, V. N.; Golubkov, A. S.
2018-01-01
The article considers the ways of regulation of pantographs to provide quality and reliability of current collection at high speeds. To assess impact of regulation was proposed integral criterion of the quality of current collection, taking into account efficiency and reliability of operation of the pantograph. The study was carried out using mathematical model of interaction of pantograph and catenary system, allowing to assess contact force and intensity of arcing at the contact zone at different movement speeds. The simulation results allowed us to estimate the efficiency of different methods of regulation of pantographs and determine the best option.
NASA Technical Reports Server (NTRS)
Witkin, S. A.
1976-01-01
Guidelines are presented for a quality assurance system to be implemented by the manufacturer in support of designing, developing, fabricating, assembling, inspecting, testing, handling, and delivery of equipment being procured for use in public urban mass transit systems. The guidelines apply to this equipment when being procured for: (1) use in revenue service; (2) demonstration of systems that will be revenue producing or used by the public; (3) use as a prototype for follow-on operational/revenue producing equipment procurements; and (4) qualification tests.
76 FR 62644 - Request To Consider Automatic Termination Controls
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-11
... Consider Automatic Termination Controls AGENCY: Office of the General Counsel, Department of Energy (DOE... dryer test procedure be amended to address the effectiveness of automatic termination controls such as moisture and temperature sensor controls. Public comment is requested on whether DOE should grant the...
Alejo, L; Corredoira, E; Sánchez-Muñoz, F; Huerga, C; Aza, Z; Plaza-Núñez, R; Serrada, A; Bret-Zurita, M; Parrón, M; Prieto-Areyano, C; Garzón-Moll, G; Madero, R; Guibelalde, E
2018-04-09
Objective: The new 2013/59 EURATOM Directive (ED) demands dosimetric optimisation procedures without undue delay. The aim of this study was to optimise paediatric conventional radiology examinations applying the ED without compromising the clinical diagnosis. Automatic dose management software (ADMS) was used to analyse 2678 studies of children from birth to 5 years of age, obtaining local diagnostic reference levels (DRLs) in terms of entrance surface air kerma. Given local DRL for infants and chest examinations exceeded the European Commission (EC) DRL, an optimisation was performed decreasing the kVp and applying the automatic control exposure. To assess the image quality, an analysis of high-contrast resolution (HCSR), signal-to-noise ratio (SNR) and figure of merit (FOM) was performed, as well as a blind test based on the generalised estimating equations method. For newborns and chest examinations, the local DRL exceeded the EC DRL by 113%. After the optimisation, a reduction of 54% was obtained. No significant differences were found in the image quality blind test. A decrease in SNR (-37%) and HCSR (-68%), and an increase in FOM (42%), was observed. ADMS allows the fast calculation of local DRLs and the performance of optimisation procedures in babies without delay. However, physical and clinical analyses of image quality remain to be needed to ensure the diagnostic integrity after the optimisation process. Advances in knowledge: ADMS are useful to detect radiation protection problems and to perform optimisation procedures in paediatric conventional imaging without undue delay, as ED requires.
Torres, Viviana; Cerda, Mauricio; Knaup, Petra; Löpprich, Martin
2016-01-01
An important part of the electronic information available in Hospital Information System (HIS) has the potential to be automatically exported to Electronic Data Capture (EDC) platforms for improving clinical research. This automation has the advantage of reducing manual data transcription, a time consuming and prone to errors process. However, quantitative evaluations of the process of exporting data from a HIS to an EDC system have not been reported extensively, in particular comparing with manual transcription. In this work an assessment to study the quality of an automatic export process, focused in laboratory data from a HIS is presented. Quality of the laboratory data was assessed in two types of processes: (1) a manual process of data transcription, and (2) an automatic process of data transference. The automatic transference was implemented as an Extract, Transform and Load (ETL) process. Then, a comparison was carried out between manual and automatic data collection methods. The criteria to measure data quality were correctness and completeness. The manual process had a general error rate of 2.6% to 7.1%, obtaining the lowest error rate if data fields with a not clear definition were removed from the analysis (p < 10E-3). In the case of automatic process, the general error rate was 1.9% to 12.1%, where lowest error rate is obtained when excluding information missing in the HIS but transcribed to the EDC from other physical sources. The automatic ETL process can be used to collect laboratory data for clinical research if data in the HIS as well as physical documentation not included in HIS, are identified previously and follows a standardized data collection protocol.
Reisner, Andrew T; Chen, Liangyou; McKenna, Thomas M; Reifman, Jaques
2008-10-01
Prehospital severity scores can be used in routine prehospital care, mass casualty care, and military triage. If computers could reliably calculate clinical scores, new clinical and research methodologies would be possible. One obstacle is that vital signs measured automatically can be unreliable. We hypothesized that Signal Quality Indices (SQI's), computer algorithms that differentiate between reliable and unreliable monitored physiologic data, could improve the predictive power of computer-calculated scores. In a retrospective analysis of trauma casualties transported by air ambulance, we computed the Triage Revised Trauma Score (RTS) from archived travel monitor data. We compared the areas-under-the-curve (AUC's) of receiver operating characteristic curves for prediction of mortality and red blood cell transfusion for 187 subjects with comparable quantities of good-quality and poor-quality data. Vital signs deemed reliable by SQI's led to significantly more discriminatory severity scores than vital signs deemed unreliable. We also compared automatically-computed RTS (using the SQI's) versus RTS computed from vital signs documented by medics. For the subjects in whom the SQI algorithms identified 15 consecutive seconds of reliable vital signs data (n = 350), the automatically-computed scores' AUC's were the same as the medic-based scores' AUC's. Using the Prehospital Index in place of RTS led to very similar results, corroborating our findings. SQI algorithms improve automatically-computed severity scores, and automatically-computed scores using SQI's are equivalent to medic-based scores.
46 CFR 61.30-20 - Automatic control and safety tests.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Automatic control and safety tests. 61.30-20 Section 61... TESTS AND INSPECTIONS Tests and Inspections of Fired Thermal Fluid Heaters § 61.30-20 Automatic control and safety tests. Operational tests and checks of all safety and limit controls, combustion controls...
Forest Clearcutting and Site Preparation on a Saline Soil in East Texas: Impacts on Water Quality
Matthew McBroom; Mingteh Chang; Alexander K. Sayok
2002-01-01
Three 0.02 hectare plot-watersheds were installed on a saline soil in the Davy Crockett National Forest near Apple Springs, Texas. Each plot was installed with an H-flume, FW-1 automatic water level recorder, Coshocton N-1 runoff sampler, and two storage tanks. One watershed was undisturbed forested and served a control, one was clearcut without any site-preparation,...
Seismic Motion Stability, Measurement and Precision Control.
1979-12-01
tiltmeter . Tilt was corrected by changing air pressure in one bank of isolators to maintain the reference tiltmeter at null well within the 0.1 arcsecond...frequency rotations (0-0.1 Hz), a high quality, two-axis tiltmeter is used. The azimuth orientation angle could be measured with a four-position gyro...compassing system with considerably less accuracy than the tiltmeters . However, it would provide a continuous automatic azimuth determination update every
Charnock, P; Jones, R; Fazakerley, J; Wilde, R; Dunn, A F
2011-09-01
Data are currently being collected from hospital radiology information systems in the North West of the UK for the purposes of both clinical audit and patient dose audit. Could these data also be used to satisfy quality assurance (QA) requirements according to UK guidance? From 2008 to 2009, 731 653 records were submitted from 8 hospitals from the North West England. For automatic exposure control QA, the protocol from Institute of Physics and Engineering in Medicine (IPEM) report 91 recommends that milliamperes per second can be monitored for repeatability and reproducibility using a suitable phantom, at 70-81 kV. Abdomen AP and chest PA examinations were analysed to find the most common kilovoltage used with these records then used to plot average monthly milliamperes per second with time. IPEM report 91 also recommends that a range of commonly used clinical settings is used to check output reproducibility and repeatability. For each tube, the dose area product values were plotted over time for two most common exposure factor sets. Results show that it is possible to do performance checks of AEC systems; however more work is required to be able to monitor tube output performance. Procedurally, the management system requires work and the benefits to the workflow would need to be demonstrated.
Automatic control of cryogenic wind tunnels
NASA Technical Reports Server (NTRS)
Balakrishna, S.
1989-01-01
Inadequate Reynolds number similarity in testing of scaled models affects the quality of aerodynamic data from wind tunnels. This is due to scale effects of boundary-layer shock wave interaction which is likely to be severe at transonic speeds. The idea of operation of wind tunnels using test gas cooled to cryogenic temperatures has yielded a quantrum jump in the ability to realize full scale Reynolds number flow similarity in small transonic tunnels. In such tunnels, the basic flow control problem consists of obtaining and maintaining the desired test section flow parameters. Mach number, Reynolds number, and dynamic pressure are the three flow parameters that are usually required to be kept constant during the period of model aerodynamic data acquisition. The series of activity involved in modeling, control law development, mechanization of the control laws on a microcomputer, and the performance of a globally stable automatic control system for the 0.3-m Transonic Cryogenic Tunnel (TCT) are discussed. A lumped multi-variable nonlinear dynamic model of the cryogenic tunnel, generation of a set of linear control laws for small perturbation, and nonlinear control strategy for large set point changes including tunnel trajectory control are described. The details of mechanization of the control laws on a 16 bit microcomputer system, the software features, operator interface, the display and safety are discussed. The controller is shown to provide globally stable and reliable temperature control to + or - 0.2 K, pressure to + or - 0.07 psi and Mach number to + or - 0.002 of the set point value. This performance is obtained both during large set point commands as for a tunnel cooldown, and during aerodynamic data acquisition with intrusive activity like geometrical changes in the test section such as angle of attack changes, drag rake movements, wall adaptation and sidewall boundary-layer removal. Feasibility of the use of an automatic Reynolds number control mode with fixed Mach number control is demonstrated.
Automatic sample Dewar for MX beam-line
DOE Office of Scientific and Technical Information (OSTI.GOV)
Charignon, T.; Tanchon, J.; Trollier, T.
2014-01-29
It is very common for crystals of large biological macromolecules to show considerable variation in quality of their diffraction. In order to increase the number of samples that are tested for diffraction quality before any full data collections at the ESRF*, an automatic sample Dewar has been implemented. Conception and performances of the Dewar are reported in this paper. The automatic sample Dewar has 240 samples capability with automatic loading/unloading ports. The storing Dewar is capable to work with robots and it can be integrated in a full automatic MX** beam-line. The samples are positioned in the front of themore » loading/unloading ports with and automatic rotating plate. A view port has been implemented for data matrix camera reading on each sample loaded in the Dewar. At last, the Dewar is insulated with polyurethane foam that keeps the liquid nitrogen consumption below 1.6 L/h. At last, the static insulation also makes vacuum equipment and maintenance unnecessary. This Dewar will be useful for increasing the number of samples tested in synchrotrons.« less
49 CFR 235.5 - Changes requiring filing of application.
Code of Federal Regulations, 2010 CFR
2010-10-01
... system, automatic train stop, train control, or cab signal system or other similar appliance or device..., automatic train stop, train control, or cab signal system; or (3) The modification of a block signal system, interlocking, traffic control system, automatic train stop, train control, or cab signal system. (b) [Reserved...
49 CFR 235.5 - Changes requiring filing of application.
Code of Federal Regulations, 2011 CFR
2011-10-01
... system, automatic train stop, train control, or cab signal system or other similar appliance or device..., automatic train stop, train control, or cab signal system; or (3) The modification of a block signal system, interlocking, traffic control system, automatic train stop, train control, or cab signal system. (b) [Reserved...
Wei, Kang-Lin; Wen, Zhi-Yu; Guo, Jian; Chen, Song-Bo
2012-07-01
Aiming at the monitoring and protecting of water resource environment, a multi-parameter water quality monitoring microsystem based on microspectrometer was put forward in the present paper. The microsystem is mainly composed of MOEMS microspectrometer, flow paths system and embedded measuring & controlling system. It has the functions of self-injecting samples and detection regents, automatic constant temperature, self -stirring, self- cleaning and samples' spectrum detection. The principle prototype machine of the microsystem was developed, and its structure principle was introduced in the paper. Through experiment research, it was proved that the principle prototype machine can rapidly detect quite a few water quality parameters and can meet the demands of on-line water quality monitoring, moreover, the principle prototype machine has strong function expansibility.
Pichler, Peter; Mazanek, Michael; Dusberger, Frederico; Weilnböck, Lisa; Huber, Christian G; Stingl, Christoph; Luider, Theo M; Straube, Werner L; Köcher, Thomas; Mechtler, Karl
2012-11-02
While the performance of liquid chromatography (LC) and mass spectrometry (MS) instrumentation continues to increase, applications such as analyses of complete or near-complete proteomes and quantitative studies require constant and optimal system performance. For this reason, research laboratories and core facilities alike are recommended to implement quality control (QC) measures as part of their routine workflows. Many laboratories perform sporadic quality control checks. However, successive and systematic longitudinal monitoring of system performance would be facilitated by dedicated automatic or semiautomatic software solutions that aid an effortless analysis and display of QC metrics over time. We present the software package SIMPATIQCO (SIMPle AuTomatIc Quality COntrol) designed for evaluation of data from LTQ Orbitrap, Q-Exactive, LTQ FT, and LTQ instruments. A centralized SIMPATIQCO server can process QC data from multiple instruments. The software calculates QC metrics supervising every step of data acquisition from LC and electrospray to MS. For each QC metric the software learns the range indicating adequate system performance from the uploaded data using robust statistics. Results are stored in a database and can be displayed in a comfortable manner from any computer in the laboratory via a web browser. QC data can be monitored for individual LC runs as well as plotted over time. SIMPATIQCO thus assists the longitudinal monitoring of important QC metrics such as peptide elution times, peak widths, intensities, total ion current (TIC) as well as sensitivity, and overall LC-MS system performance; in this way the software also helps identify potential problems. The SIMPATIQCO software package is available free of charge.
2012-01-01
While the performance of liquid chromatography (LC) and mass spectrometry (MS) instrumentation continues to increase, applications such as analyses of complete or near-complete proteomes and quantitative studies require constant and optimal system performance. For this reason, research laboratories and core facilities alike are recommended to implement quality control (QC) measures as part of their routine workflows. Many laboratories perform sporadic quality control checks. However, successive and systematic longitudinal monitoring of system performance would be facilitated by dedicated automatic or semiautomatic software solutions that aid an effortless analysis and display of QC metrics over time. We present the software package SIMPATIQCO (SIMPle AuTomatIc Quality COntrol) designed for evaluation of data from LTQ Orbitrap, Q-Exactive, LTQ FT, and LTQ instruments. A centralized SIMPATIQCO server can process QC data from multiple instruments. The software calculates QC metrics supervising every step of data acquisition from LC and electrospray to MS. For each QC metric the software learns the range indicating adequate system performance from the uploaded data using robust statistics. Results are stored in a database and can be displayed in a comfortable manner from any computer in the laboratory via a web browser. QC data can be monitored for individual LC runs as well as plotted over time. SIMPATIQCO thus assists the longitudinal monitoring of important QC metrics such as peptide elution times, peak widths, intensities, total ion current (TIC) as well as sensitivity, and overall LC–MS system performance; in this way the software also helps identify potential problems. The SIMPATIQCO software package is available free of charge. PMID:23088386
NASA Astrophysics Data System (ADS)
Hufenbach, W.; Gude, M.; Czulak, A.; Kretschmann, Martin
2014-04-01
Increasing economic, political and ecological pressure leads to steadily rising percentage of modern processing and manufacturing processes for fibre reinforced polymers in industrial batch production. Component weights beneath a level achievable by classic construction materials, which lead to a reduced energy and cost balance during product lifetime, justify the higher fabrication costs. However, complex quality control and failure prediction slow down the substitution by composite materials. High-resolution fibre-optic sensors (FOS), due their low diameter, high measuring point density and simple handling, show a high applicability potential for an automated sensor-integration in manufacturing processes, and therefore the online monitoring of composite products manufactured in industrial scale. Integrated sensors can be used to monitor manufacturing processes, part tests as well as the component structure during product life cycle, which simplifies allows quality control during production and the optimization of single manufacturing processes.[1;2] Furthermore, detailed failure analyses lead to a enhanced understanding of failure processes appearing in composite materials. This leads to a lower wastrel number and products of a higher value and longer product life cycle, whereby costs, material and energy are saved. This work shows an automation approach for FOS-integration in the braiding process. For that purpose a braiding wheel has been supplemented with an appliance for automatic sensor application, which has been used to manufacture preforms of high-pressure composite vessels with FOS-networks integrated between the fibre layers. All following manufacturing processes (vacuum infiltration, curing) and component tests (quasi-static pressure test, programmed delamination) were monitored with the help of the integrated sensor networks. Keywords: SHM, high-pressure composite vessel, braiding, automated sensor integration, pressure test, quality control, optic-fibre sensors, Rayleigh, Luna Technologies
Automated image quality assessment for chest CT scans.
Reeves, Anthony P; Xie, Yiting; Liu, Shuang
2018-02-01
Medical image quality needs to be maintained at standards sufficient for effective clinical reading. Automated computer analytic methods may be applied to medical images for quality assessment. For chest CT scans in a lung cancer screening context, an automated quality assessment method is presented that characterizes image noise and image intensity calibration. This is achieved by image measurements in three automatically segmented homogeneous regions of the scan: external air, trachea lumen air, and descending aorta blood. Profiles of CT scanner behavior are also computed. The method has been evaluated on both phantom and real low-dose chest CT scans and results show that repeatable noise and calibration measures may be realized by automated computer algorithms. Noise and calibration profiles show relevant differences between different scanners and protocols. Automated image quality assessment may be useful for quality control for lung cancer screening and may enable performance improvements to automated computer analysis methods. © 2017 American Association of Physicists in Medicine.
Vignally, P; Fondi, G; Taggi, F; Pitidis, A
2011-03-31
In Italy the European Union Injury Database reports the involvement of chemical products in 0.9% of home and leisure accidents. The Emergency Department registry on domestic accidents in Italy and the Poison Control Centres record that 90% of cases of exposure to toxic substances occur in the home. It is not rare for the effects of chemical agents to be observed in hospitals, with a high potential risk of damage - the rate of this cause of hospital admission is double the domestic injury average. The aim of this study was to monitor the effects of injuries caused by caustic agents in Italy using automatic free-text recognition in Emergency Department medical databases. We created a Stata software program to automatically identify caustic or corrosive injury cases using an agent-specific list of keywords. We focused attention on the procedure's sensitivity and specificity. Ten hospitals in six regions of Italy participated in the study. The program identified 112 cases of injury by caustic or corrosive agents. Checking the cases by quality controls (based on manual reading of ED reports), we assessed 99 cases as true positive, i.e. 88.4% of the patients were automatically recognized by the software as being affected by caustic substances (99% CI: 80.6%- 96.2%), that is to say 0.59% (99% CI: 0.45%-0.76%) of the whole sample of home injuries, a value almost three times as high as that expected (p < 0.0001) from European codified information. False positives were 11.6% of the recognized cases (99% CI: 5.1%- 21.5%). Our automatic procedure for caustic agent identification proved to have excellent product recognition capacity with an acceptable level of excess sensitivity. Contrary to our a priori hypothesis, the automatic recognition system provided a level of identification of agents possessing caustic effects that was significantly much greater than was predictable on the basis of the values from current codifications reported in the European Database.
47 CFR 97.221 - Automatically controlled digital station.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Automatically controlled digital station. 97.221 Section 97.221 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES AMATEUR RADIO SERVICE Special Operations § 97.221 Automatically controlled digital...
Sauer, Vernon B.
2002-01-01
Surface-water computation methods and procedures are described in this report to provide standards from which a completely automated electronic processing system can be developed. To the greatest extent possible, the traditional U. S. Geological Survey (USGS) methodology and standards for streamflow data collection and analysis have been incorporated into these standards. Although USGS methodology and standards are the basis for this report, the report is applicable to other organizations doing similar work. The proposed electronic processing system allows field measurement data, including data stored on automatic field recording devices and data recorded by the field hydrographer (a person who collects streamflow and other surface-water data) in electronic field notebooks, to be input easily and automatically. A user of the electronic processing system easily can monitor the incoming data and verify and edit the data, if necessary. Input of the computational procedures, rating curves, shift requirements, and other special methods are interactive processes between the user and the electronic processing system, with much of this processing being automatic. Special computation procedures are provided for complex stations such as velocity-index, slope, control structures, and unsteady-flow models, such as the Branch-Network Dynamic Flow Model (BRANCH). Navigation paths are designed to lead the user through the computational steps for each type of gaging station (stage-only, stagedischarge, velocity-index, slope, rate-of-change in stage, reservoir, tide, structure, and hydraulic model stations). The proposed electronic processing system emphasizes the use of interactive graphics to provide good visual tools for unit values editing, rating curve and shift analysis, hydrograph comparisons, data-estimation procedures, data review, and other needs. Documentation, review, finalization, and publication of records are provided for with the electronic processing system, as well as archiving, quality assurance, and quality control.
Willems, Elise; Smismans, Annick; Cartuyvels, Reinoud; Coppens, Guy; Van Vaerenbergh, Kristien; Van den Abeele, Anne-Marie; Frans, Johan
2012-05-01
Bloodstream infections remain a major challenge in medicine. Optimal detection of pathogens is only possible if the quality of preanalytical factors is thoroughly controlled. Since the laboratory is responsible for this preanalytical phase, the quality control of critical factors should be integrated in its quality control program. The numerous recommendations regarding blood culture collection contain controversies. Only an unambiguous guideline permits standardization and interlaboratory quality control. We present an evidence-based concise guideline of critical preanalytical determinants for blood culture collection and summarize key performance indicators with their concomitant target values. In an attempt to benchmark, we compared the true-positive rate, contamination rate, and collected blood volume of blood culture bottles in 5 Belgian hospital laboratories. The true-positive blood culture rate fell within previously defined acceptation criteria by Baron et al. (2005) in all 5 hospitals, whereas the contamination rate exceeded the target value in 4 locations. Most unexpected, in each of the 5 laboratories, more than one third of the blood culture bottles were incorrectly filled, irrespective of the manufacturer of the blood culture vials. As a consequence of this shortcoming, one manufacturer recently developed an automatic blood volume monitoring system. In conclusion, clear recommendations for standardized blood culture collection combined with quality control of critical factors of the preanalytical phase are essential for diagnostic blood culture improvement. Copyright © 2012 Elsevier Inc. All rights reserved.
Quantification of regional fat volume in rat MRI
NASA Astrophysics Data System (ADS)
Sacha, Jaroslaw P.; Cockman, Michael D.; Dufresne, Thomas E.; Trokhan, Darren
2003-05-01
Multiple initiatives in the pharmaceutical and beauty care industries are directed at identifying therapies for weight management. Body composition measurements are critical for such initiatives. Imaging technologies that can be used to measure body composition noninvasively include DXA (dual energy x-ray absorptiometry) and MRI (magnetic resonance imaging). Unlike other approaches, MRI provides the ability to perform localized measurements of fat distribution. Several factors complicate the automatic delineation of fat regions and quantification of fat volumes. These include motion artifacts, field non-uniformity, brightness and contrast variations, chemical shift misregistration, and ambiguity in delineating anatomical structures. We have developed an approach to deal practically with those challenges. The approach is implemented in a package, the Fat Volume Tool, for automatic detection of fat tissue in MR images of the rat abdomen, including automatic discrimination between abdominal and subcutaneous regions. We suppress motion artifacts using masking based on detection of implicit landmarks in the images. Adaptive object extraction is used to compensate for intensity variations. This approach enables us to perform fat tissue detection and quantification in a fully automated manner. The package can also operate in manual mode, which can be used for verification of the automatic analysis or for performing supervised segmentation. In supervised segmentation, the operator has the ability to interact with the automatic segmentation procedures to touch-up or completely overwrite intermediate segmentation steps. The operator's interventions steer the automatic segmentation steps that follow. This improves the efficiency and quality of the final segmentation. Semi-automatic segmentation tools (interactive region growing, live-wire, etc.) improve both the accuracy and throughput of the operator when working in manual mode. The quality of automatic segmentation has been evaluated by comparing the results of fully automated analysis to manual analysis of the same images. The comparison shows a high degree of correlation that validates the quality of the automatic segmentation approach.
Online automatic tuning and control for fed-batch cultivation
van Straten, Gerrit; van der Pol, Leo A.; van Boxtel, Anton J. B.
2007-01-01
Performance of controllers applied in biotechnological production is often below expectation. Online automatic tuning has the capability to improve control performance by adjusting control parameters. This work presents automatic tuning approaches for model reference specific growth rate control during fed-batch cultivation. The approaches are direct methods that use the error between observed specific growth rate and its set point; systematic perturbations of the cultivation are not necessary. Two automatic tuning methods proved to be efficient, in which the adaptation rate is based on a combination of the error, squared error and integral error. These methods are relatively simple and robust against disturbances, parameter uncertainties, and initialization errors. Application of the specific growth rate controller yields a stable system. The controller and automatic tuning methods are qualified by simulations and laboratory experiments with Bordetella pertussis. PMID:18157554
Greffier, Joël; Pereira, Fabricio; Macri, Francesco; Beregi, Jean-Paul; Larbi, Ahmed
2016-04-01
To evaluate the impact of Automatic Exposure Control (AEC) on radiation dose and image quality in paediatric chest scans (MDCT), with or without iterative reconstruction (IR). Three anthropomorphic phantoms representing children aged one, five and 10-year-old were explored using AEC system (CARE Dose 4D) with five modulation strength options. For each phantom, six acquisitions were carried out: one with fixed mAs (without AEC) and five each with different modulation strength. Raw data were reconstructed with Filtered Back Projection (FBP) and with two distinct levels of IR using soft and strong kernels. Dose reduction and image quality indices (Noise, SNR, CNR) were measured in lung and soft tissues. Noise Power Spectrum (NPS) was evaluated with a Catphan 600 phantom. The use of AEC produced a significant dose reduction (p<0.01) for all anthropomorphic sizes employed. According to the modulation strength applied, dose delivered was reduced from 43% to 91%. This pattern led to significantly increased noise (p<0.01) and reduced SNR and CNR (p<0.01). However, IR was able to improve these indices. The use of AEC/IR preserved image quality indices with a lower dose delivered. Doses were reduced from 39% to 58% for the one-year-old phantom, from 46% to 63% for the five-year-old phantom, and from 58% to 74% for the 10-year-old phantom. In addition, AEC/IR changed the patterns of NPS curves in amplitude and in spatial frequency. In chest paediatric MDCT, the use of AEC with IR allows one to obtain a significant dose reduction while maintaining constant image quality indices. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Considerations In The Design And Specifications Of An Automatic Inspection System
NASA Astrophysics Data System (ADS)
Lee, David T.
1980-05-01
Considerable activities have been centered around the automation of manufacturing quality control and inspection functions. Several reasons can be cited for this development. The continuous pressure of direct and indirect labor cost increase is only one of the obvious motivations. With the drive for electronics miniaturization come more and more complex processes where control parameters are critical and the yield is highly susceptible to inadequate process monitor and inspection. With multi-step, multi-layer process for substrate fabrication, process defects that are not detected and corrected at certain critical points may render the entire subassembly useless. As a process becomes more complex, the time required to test the product increases significantly in the total build cycle. The urgency to reduce test time brings more pressure to improve in-process control and inspection. The advances and improvements of components, assemblies and systems such as micro-processors, micro-computers, programmable controllers, and other intelligent devices, have made the automation of quality control much more cost effective and justifiable.
75 FR 59326 - Eighth Meeting-RTCA Special Committee 220: Automatic Flight Guidance and Control
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-27
... Committee 220: Automatic Flight Guidance and Control AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 220: Automatic Flight Guidance and Control meeting. SUMMARY: The... Flight Guidance and Control. DATES: The meeting will be held October 12-14, 2010. October 12th and 13th...
Code of Federal Regulations, 2011 CFR
2011-10-01
... TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Traffic Control Systems Standards § 236.401 Automatic... 49 Transportation 4 2011-10-01 2011-10-01 false Automatic block signal system and interlocking standards applicable to traffic control systems. 236.401 Section 236.401 Transportation Other Regulations...
3D image processing architecture for camera phones
NASA Astrophysics Data System (ADS)
Atanassov, Kalin; Ramachandra, Vikas; Goma, Sergio R.; Aleksic, Milivoje
2011-03-01
Putting high quality and easy-to-use 3D technology into the hands of regular consumers has become a recent challenge as interest in 3D technology has grown. Making 3D technology appealing to the average user requires that it be made fully automatic and foolproof. Designing a fully automatic 3D capture and display system requires: 1) identifying critical 3D technology issues like camera positioning, disparity control rationale, and screen geometry dependency, 2) designing methodology to automatically control them. Implementing 3D capture functionality on phone cameras necessitates designing algorithms to fit within the processing capabilities of the device. Various constraints like sensor position tolerances, sensor 3A tolerances, post-processing, 3D video resolution and frame rate should be carefully considered for their influence on 3D experience. Issues with migrating functions such as zoom and pan from the 2D usage model (both during capture and display) to 3D needs to be resolved to insure the highest level of user experience. It is also very important that the 3D usage scenario (including interactions between the user and the capture/display device) is carefully considered. Finally, both the processing power of the device and the practicality of the scheme needs to be taken into account while designing the calibration and processing methodology.
Searchfield, Grant D; Linford, Tania; Kobayashi, Kei; Crowhen, David; Latzel, Matthias
2018-03-01
To compare preference for and performance of manually selected programmes to an automatic sound classifier, the Phonak AutoSense OS. A single blind repeated measures study. Participants were fit with Phonak Virto V90 ITE aids; preferences for different listening programmes were compared across four different sound scenarios (speech in: quiet, noise, loud noise and a car). Following a 4-week trial preferences were reassessed and the users preferred programme was compared to the automatic classifier for sound quality and hearing in noise (HINT test) using a 12 loudspeaker array. Twenty-five participants with symmetrical moderate-severe sensorineural hearing loss. Participant preferences of manual programme for scenarios varied considerably between and within sessions. A HINT Speech Reception Threshold (SRT) advantage was observed for the automatic classifier over participant's manual selection for speech in quiet, loud noise and car noise. Sound quality ratings were similar for both manual and automatic selections. The use of a sound classifier is a viable alternative to manual programme selection.
Collette, Fabienne; Van der Linden, Martial; Salmon, Eric
2010-01-01
A decline of cognitive functioning affecting several cognitive domains was frequently reported in patients with frontotemporal dementia. We were interested in determining if these deficits can be interpreted as reflecting an impairment of controlled cognitive processes by using an assessment tool specifically developed to explore the distinction between automatic and controlled processes, namely the process dissociation procedure (PDP) developed by Jacoby. The PDP was applied to a word stem completion task to determine the contribution of automatic and controlled processes to episodic memory performance and was administered to a group of 12 patients with the behavioral variant of frontotemporal dementia (bv-FTD) and 20 control subjects (CS). Bv-FTD patients obtained a lower performance than CS for the estimates of controlled processes, but no group differences was observed for estimates of automatic processes. The between-groups comparison of the estimates of controlled and automatic processes showed a larger contribution of automatic processes to performance in bv-FTD, while a slightly more important contribution of controlled processes was observed in control subjects. These results are clearly indicative of an alteration of controlled memory processes in bv-FTD.
NASA Astrophysics Data System (ADS)
Sanger, Demas S.; Haneishi, Hideaki; Miyake, Yoichi
1995-08-01
This paper proposed a simple and automatic method for recognizing the light sources from various color negative film brands by means of digital image processing. First, we stretched the image obtained from a negative based on the standardized scaling factors, then extracted the dominant color component among red, green, and blue components of the stretched image. The dominant color component became the discriminator for the recognition. The experimental results verified that any one of the three techniques could recognize the light source from negatives of any film brands and all brands greater than 93.2 and 96.6% correct recognitions, respectively. This method is significant for the automation of color quality control in color reproduction from color negative film in mass processing and printing machine.
Automatic control system for uniformly paving iron ore pellets
NASA Astrophysics Data System (ADS)
Wang, Bowen; Qian, Xiaolong
2014-05-01
In iron and steelmaking industry, iron ore pellet qualities are crucial to end-product properties, manufacturing costs and waste emissions. Uniform pellet pavements on the grate machine are a fundamental prerequisite to ensure even heat-transfer and pellet induration successively influences performance of the following metallurgical processes. This article presents an automatic control system for uniformly paving green pellets on the grate, via a mechanism mainly constituted of a mechanical linkage, a swinging belt, a conveyance belt and a grate. Mechanism analysis illustrates that uniform pellet pavements demand the frontend of the swinging belt oscillate at a constant angular velocity. Subsequently, kinetic models are formulated to relate oscillatory movements of the swinging belt's frontend to rotations of a crank link driven by a motor. On basis of kinetic analysis of the pellet feeding mechanism, a cubic B-spline model is built for numerically computing discrete frequencies to be modulated during a motor rotation. Subsequently, the pellet feeding control system is presented in terms of compositional hardware and software components, and their functional relationships. Finally, pellet feeding experiments are carried out to demonstrate that the control system is effective, reliable and superior to conventional methods.
Automatic quality assessment of planetary images
NASA Astrophysics Data System (ADS)
Sidiropoulos, P.; Muller, J.-P.
2015-10-01
A significant fraction of planetary images are corrupted beyond the point that much scientific meaning can be extracted. For example, transmission errors result in missing data which is unrecoverable. The available planetary image datasets include many such "bad data", which both occupy valuable scientific storage resources and create false impressions about planetary image availability for specific planetary objects or target areas. In this work, we demonstrate a pipeline that we have developed to automatically assess the quality of planetary images. Additionally, this method discriminates between different types of image degradation, such as low-quality originating from camera flaws or low-quality triggered by atmospheric conditions, etc. Examples of quality assessment results for Viking Orbiter imagery will be also presented.
Teixeira, Miguel; Mendonça, Teresa; Rocha, Paula; Rabiço, Rui
2014-12-01
This paper presents a model based switching control strategy to drive the neuromuscular blockade (NMB) level of patients undergoing general anesthesia to a predefined reference. A single-input single-output Wiener system with only two parameters is used to model the effect of two different muscle relaxants, atracurium and rocuronium, and a switching controller is designed based on a bank of total system mass control laws. Each of such laws is tuned for an individual model from a bank chosen to represent the behavior of the whole population. The control law to be applied at each instant corresponds to the model whose NMB response is closer to the patient's response. Moreover a scheme to improve the reference tracking quality based on the analysis of the patient's response, as well as, a comparison between the switching strategy and the Extended Kalman Kilter (EKF) technique are presented. The results are illustrated by means of several simulations, where switching shows to provide good results, both in theory and in practice, with a desirable reference tracking. The reference tracking improvement technique is able to produce a better reference tracking. Also, this technique showed a better performance than the (EKF). Based on these results, the switching control strategy with a bank of total system mass control laws proved to be robust enough to be used as an automatic control system for the NMB level.
Attention to Automatic Movements in Parkinson's Disease: Modified Automatic Mode in the Striatum
Wu, Tao; Liu, Jun; Zhang, Hejia; Hallett, Mark; Zheng, Zheng; Chan, Piu
2015-01-01
We investigated neural correlates when attending to a movement that could be made automatically in healthy subjects and Parkinson's disease (PD) patients. Subjects practiced a visuomotor association task until they could perform it automatically, and then directed their attention back to the automated task. Functional MRI was obtained during the early-learning, automatic stage, and when re-attending. In controls, attention to automatic movement induced more activation in the dorsolateral prefrontal cortex (DLPFC), anterior cingulate cortex, and rostral supplementary motor area. The motor cortex received more influence from the cortical motor association regions. In contrast, the pattern of the activity and connectivity of the striatum remained at the level of the automatic stage. In PD patients, attention enhanced activity in the DLPFC, premotor cortex, and cerebellum, but the connectivity from the putamen to the motor cortex decreased. Our findings demonstrate that, in controls, when a movement achieves the automatic stage, attention can influence the attentional networks and cortical motor association areas, but has no apparent effect on the striatum. In PD patients, attention induces a shift from the automatic mode back to the controlled pattern within the striatum. The shifting between controlled and automatic behaviors relies in part on striatal function. PMID:24925772
NASA Astrophysics Data System (ADS)
Zhan, Jinliang; Lu, Pei
2006-11-01
Since the quality of traditional Chinese medicine products are affected by raw material, machining and many other factors, it is difficult for traditional Chinese medicine production process especially the extracting process to ensure the steady and homogeneous quality. At the same time, there exist some quality control blind spots due to lacking on-line quality detection means. But if infrared spectrum analysis technology was used in traditional Chinese medicine production process on the basis of off-line analysis to real-time detect the quality of semi-manufactured goods and to be assisted by advanced automatic control technique, the steady and homogeneous quality can be obtained. It can be seen that the on-line detection of extracting process plays an important role in the development of Chinese patent medicines industry. In this paper, the design and implement of a traditional Chinese medicine extracting process monitoring experiment system which is based on PROFIBUS-DP field bus, OPC, and Internet technology is introduced. The system integrates intelligence node which gathering data, superior sub-system which achieving figure configuration and remote supervisory, during the process of traditional Chinese medicine production, monitors the temperature parameter, pressure parameter, quality parameter etc. And it can be controlled by the remote nodes in the VPN (Visual Private Network). Experiment and application do have proved that the system can reach the anticipation effect fully, and with the merits of operational stability, real-time, reliable, convenient and simple manipulation and so on.
Automatic welding of stainless steel tubing
NASA Technical Reports Server (NTRS)
Clautice, W. E.
1978-01-01
The use of automatic welding for making girth welds in stainless steel tubing was investigated as well as the reduction in fabrication costs resulting from the elimination of radiographic inspection. Test methodology, materials, and techniques are discussed, and data sheets for individual tests are included. Process variables studied include welding amperes, revolutions per minute, and shielding gas flow. Strip chart recordings, as a definitive method of insuring weld quality, are studied. Test results, determined by both radiographic and visual inspection, are presented and indicate that once optimum welding procedures for specific sizes of tubing are established, and the welding machine operations are certified, then the automatic tube welding process produces good quality welds repeatedly, with a high degree of reliability. Revised specifications for welding tubing using the automatic process and weld visual inspection requirements at the Kennedy Space Center are enumerated.
Presley, Todd K.; Jamison, Marcael T.J.; Young-Smith, Stacie T. M.
2006-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data were collected at two stations, continuous discharge data at one station, continuous streamflow data at two stations, and water-quality data at five stations, which include the continuous discharge and streamflow stations. This report summarizes rainfall, discharge, streamflow, and water-quality data collected between July 1, 2005 and June 30, 2006. A total of 23 samples was collected over five storms during July 1, 2005 to June 30, 2006. The goal was to collect grab samples nearly simultaneously at all five stations, and flow-weighted time-composite samples at the three stations equipped with automatic samplers; however, all five storms were partially sampled owing to lack of flow at the time of sampling at some sites, or because some samples collected by the automatic sampler did not represent water from the storm. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). Additionally, grab samples were analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/quality-control samples were also collected during storms and during routine maintenance to verify analytical procedures and check the effectiveness of equipment-cleaning procedures.
Computer vision for automatic inspection of agricultural produce
NASA Astrophysics Data System (ADS)
Molto, Enrique; Blasco, Jose; Benlloch, Jose V.
1999-01-01
Fruit and vegetables suffer different manipulations from the field to the final consumer. These are basically oriented towards the cleaning and selection of the product in homogeneous categories. For this reason, several research projects, aimed at fast, adequate produce sorting and quality control are currently under development around the world. Moreover, it is possible to find manual and semi- automatic commercial system capable of reasonably performing these tasks.However, in many cases, their accuracy is incompatible with current European market demands, which are constantly increasing. IVIA, the Valencian Research Institute of Agriculture, located in Spain, has been involved in several European projects related with machine vision for real-time inspection of various agricultural produces. This paper will focus on the work related with two products that have different requirements: fruit and olives. In the case of fruit, the Institute has developed a vision system capable of providing assessment of the external quality of single fruit to a robot that also receives information from other senors. The system use four different views of each fruit and has been tested on peaches, apples and citrus. Processing time of each image is under 500 ms using a conventional PC. The system provides information about primary and secondary color, blemishes and their extension, and stem presence and position, which allows further automatic orientation of the fruit in the final box using a robotic manipulator. Work carried out in olives was devoted to fast sorting of olives for consumption at table. A prototype has been developed to demonstrate the feasibility of a machine vision system capable of automatically sorting 2500 kg/h olives using low-cost conventional hardware.
de Castro, Alberto; Sawides, Lucie; Qi, Xiaofeng; Burns, Stephen A
2017-08-20
Retinal imaging with an adaptive optics (AO) system usually requires that the eye be centered and stable relative to the exit pupil of the system. Aberrations are then typically corrected inside a fixed circular pupil. This approach can be restrictive when imaging some subjects, since the pupil may not be round and maintaining a stable head position can be difficult. In this paper, we present an automatic algorithm that relaxes these constraints. An image quality metric is computed for each spot of the Shack-Hartmann image to detect the pupil and its boundary, and the control algorithm is applied only to regions within the subject's pupil. Images on a model eye as well as for five subjects were obtained to show that a system exit pupil larger than the subject's eye pupil could be used for AO retinal imaging without a reduction in image quality. This algorithm automates the task of selecting pupil size. It also may relax constraints on centering the subject's pupil and on the shape of the pupil.
76 FR 38742 - Eleventh Meeting: RTCA Special Committee 220: Automatic Flight Guidance and Control
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-01
... Committee 220: Automatic Flight Guidance and Control AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 220 Meeting: Automatic Flight Guidance and Control. SUMMARY: The... Flight Guidance and Control DATES: The meeting will be held August 9-11, 2011, from 9 a.m. to 5 p.m...
75 FR 36471 - Seventh Meeting-RTCA Special Committee 220: Automatic Flight Guidance and Control
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-25
... Committee 220: Automatic Flight Guidance and Control AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 220: Automatic Flight Guidance and Control meeting. SUMMARY: The... Flight Guidance and Control. DATES: The meeting will be held July 13-15, 2010. July 13th and 14th from 9...
On a program manifold's stability of one contour automatic control systems
NASA Astrophysics Data System (ADS)
Zumatov, S. S.
2017-12-01
Methodology of analysis of stability is expounded to the one contour systems automatic control feedback in the presence of non-linearities. The methodology is based on the use of the simplest mathematical models of the nonlinear controllable systems. Stability of program manifolds of one contour automatic control systems is investigated. The sufficient conditions of program manifold's absolute stability of one contour automatic control systems are obtained. The Hurwitz's angle of absolute stability was determined. The sufficient conditions of program manifold's absolute stability of control systems by the course of plane in the mode of autopilot are obtained by means Lyapunov's second method.
Terminal Sliding Mode Tracking Controller Design for Automatic Guided Vehicle
NASA Astrophysics Data System (ADS)
Chen, Hongbin
2018-03-01
Based on sliding mode variable structure control theory, the path tracking problem of automatic guided vehicle is studied, proposed a controller design method based on the terminal sliding mode. First of all, through analyzing the characteristics of the automatic guided vehicle movement, the kinematics model is presented. Then to improve the traditional expression of terminal sliding mode, design a nonlinear sliding mode which the convergence speed is faster than the former, verified by theoretical analysis, the design of sliding mode is steady and fast convergence in the limited time. Finally combining Lyapunov method to design the tracking control law of automatic guided vehicle, the controller can make the automatic guided vehicle track the desired trajectory in the global sense as well as in finite time. The simulation results verify the correctness and effectiveness of the control law.
Design of cylindrical pipe automatic welding control system based on STM32
NASA Astrophysics Data System (ADS)
Chen, Shuaishuai; Shen, Weicong
2018-04-01
The development of modern economy makes the demand for pipeline construction and construction rapidly increasing, and the pipeline welding has become an important link in pipeline construction. At present, there are still a large number of using of manual welding methods at home and abroad, and field pipe welding especially lacks miniature and portable automatic welding equipment. An automated welding system consists of a control system, which consisting of a lower computer control panel and a host computer operating interface, as well as automatic welding machine mechanisms and welding power systems in coordination with the control system. In this paper, a new control system of automatic pipe welding based on the control panel of the lower computer and the interface of the host computer is proposed, which has many advantages over the traditional automatic welding machine.
Refining Automatically Extracted Knowledge Bases Using Crowdsourcing
Xian, Xuefeng; Cui, Zhiming
2017-01-01
Machine-constructed knowledge bases often contain noisy and inaccurate facts. There exists significant work in developing automated algorithms for knowledge base refinement. Automated approaches improve the quality of knowledge bases but are far from perfect. In this paper, we leverage crowdsourcing to improve the quality of automatically extracted knowledge bases. As human labelling is costly, an important research challenge is how we can use limited human resources to maximize the quality improvement for a knowledge base. To address this problem, we first introduce a concept of semantic constraints that can be used to detect potential errors and do inference among candidate facts. Then, based on semantic constraints, we propose rank-based and graph-based algorithms for crowdsourced knowledge refining, which judiciously select the most beneficial candidate facts to conduct crowdsourcing and prune unnecessary questions. Our experiments show that our method improves the quality of knowledge bases significantly and outperforms state-of-the-art automatic methods under a reasonable crowdsourcing cost. PMID:28588611
Handling Qualities Implications for Crewed Spacecraft Operations
NASA Technical Reports Server (NTRS)
Bailey, Randall E.; Jackson, E. Bruce; Arthur, J. J.
2012-01-01
Abstract Handling qualities embody those qualities or characteristics of an aircraft that govern the ease and precision with which a pilot is able to perform the tasks required in support of an aircraft role. These same qualities are as critical, if not more so, in the operation of spacecraft. A research, development, test, and evaluation process was put into effect to identify, understand, and interpret the engineering and human factors principles which govern the pilot-vehicle dynamic system as they pertain to space exploration missions and tasks. Toward this objective, piloted simulations were conducted at the NASA Langley Research Center and Ames Research Center for earth-orbit proximity operations and docking and lunar landing. These works provide broad guidelines for the design of spacecraft to exhibit excellent handling characteristics. In particular, this work demonstrates how handling qualities include much more than just stability and control characteristics of a spacecraft or aircraft. Handling qualities are affected by all aspects of the pilot-vehicle dynamic system, including the motion, visual and aural cues of the vehicle response as the pilot performs the required operation or task. A holistic approach to spacecraft design, including the use of manual control, automatic control, and pilot intervention/supervision is described. The handling qualities implications of design decisions are demonstrated using these pilot-in-the-loop evaluations of docking operations and lunar landings.
Revisiting the Procedures for the Vector Data Quality Assurance in Practice
NASA Astrophysics Data System (ADS)
Erdoğan, M.; Torun, A.; Boyacı, D.
2012-07-01
Immense use of topographical data in spatial data visualization, business GIS (Geographic Information Systems) solutions and applications, mobile and location-based services forced the topo-data providers to create standard, up-to-date and complete data sets in a sustainable frame. Data quality has been studied and researched for more than two decades. There have been un-countable numbers of references on its semantics, its conceptual logical and representations and many applications on spatial databases and GIS. However, there is a gap between research and practice in the sense of spatial data quality which increases the costs and decreases the efficiency of data production. Spatial data quality is well-known by academia and industry but usually in different context. The research on spatial data quality stated several issues having practical use such as descriptive information, metadata, fulfillment of spatial relationships among data, integrity measures, geometric constraints etc. The industry and data producers realize them in three stages; pre-, co- and post data capturing. The pre-data capturing stage covers semantic modelling, data definition, cataloguing, modelling, data dictionary and schema creation processes. The co-data capturing stage covers general rules of spatial relationships, data and model specific rules such as topologic and model building relationships, geometric threshold, data extraction guidelines, object-object, object-belonging class, object-non-belonging class, class-class relationships to be taken into account during data capturing. And post-data capturing stage covers specified QC (quality check) benchmarks and checking compliance to general and specific rules. The vector data quality criteria are different from the views of producers and users. But these criteria are generally driven by the needs, expectations and feedbacks of the users. This paper presents a practical method which closes the gap between theory and practice. Development of spatial data quality concepts into developments and application requires existence of conceptual, logical and most importantly physical existence of data model, rules and knowledge of realization in a form of geo-spatial data. The applicable metrics and thresholds are determined on this concrete base. This study discusses application of geo-spatial data quality issues and QA (quality assurance) and QC procedures in the topographic data production. Firstly we introduce MGCP (Multinational Geospatial Co-production Program) data profile of NATO (North Atlantic Treaty Organization) DFDD (DGIWG Feature Data Dictionary), the requirements of data owner, the view of data producers for both data capturing and QC and finally QA to fulfil user needs. Then, our practical and new approach which divides the quality into three phases is introduced. Finally, implementation of our approach to accomplish metrics, measures and thresholds of quality definitions is discussed. In this paper, especially geometry and semantics quality and quality control procedures that can be performed by the producers are discussed. Some applicable best-practices that we experienced on techniques of quality control, defining regulations that define the objectives and data production procedures are given in the final remarks. These quality control procedures should include the visual checks over the source data, captured vector data and printouts, some automatic checks that can be performed by software and some semi-automatic checks by the interaction with quality control personnel. Finally, these quality control procedures should ensure the geometric, semantic, attribution and metadata quality of vector data.
Quality Evaluation of Coatings by Automatic Scratch Testing
1989-11-01
MTL TR 89-98 IADII QUALITY EVALUATION OF COATINGS BY AUTOMATIC SCRATCH TESTING KIRIT J. BHANSALI LBRTR A1 U.S. ARMY MATERIALS TECHNOLOGY LABORATORY...distribution unlimited. LABORATORY COMMANO U.S. ARMY MATERIALS TECHNOLOGY LABORATORY PMUNKS wcamaauv LUaAMUv Watertown, Massachusetts 02172-0001 .o...Theo 7- Kattamis* 9 PEWNWING ORGANIZATION NAME AMO ADDRESS 1.PORUEEET RJC.TS AREA & WORK UNIT NUMSS U.S. Army Materials Technology Laboratory Watertown
49 CFR 236.504 - Operation interconnected with automatic block-signal system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.504... or train control system shall operate in connection with an automatic block signal system and shall...
The Interplay between Automatic and Control Processes in Reading.
ERIC Educational Resources Information Center
Walczyk, Jeffrey J.
2000-01-01
Reviews prominent reading theories in light of their accounts of how automatic and control processes combine to produce successful text comprehension, and the trade-offs between the two. Presents the Compensatory-Encoding Model of reading, which explicates how, when, and why automatic and control processes interact. Notes important educational…
Kim, H C; Khanwilkar, P S; Bearnson, G B; Olsen, D B
1997-01-01
An automatic physiological control system for the actively filled, alternately pumped ventricles of the volumetrically coupled, electrohydraulic total artificial heart (EHTAH) was developed for long-term use. The automatic control system must ensure that the device: 1) maintains a physiological response of cardiac output, 2) compensates for an nonphysiological condition, and 3) is stable, reliable, and operates at a high power efficiency. The developed automatic control system met these requirements both in vitro, in week-long continuous mock circulation tests, and in vivo, in acute open-chested animals (calves). Satisfactory results were also obtained in a series of chronic animal experiments, including 21 days of continuous operation of the fully automatic control mode, and 138 days of operation in a manual mode, in a 159-day calf implant.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhukov, A. V.; Komarov, A. N.; Safronov, A. N.
The principles of central control of the power generating units of thermal power plants by automatic secondary frequency and active power overcurrent regulation systems, and the algorithms for interactions between automatic power control systems for the power production units in thermal power plants and centralized systems for automatic frequency and power regulation, are discussed. The order of switching the power generating units of thermal power plants over to control by a centralized system for automatic frequency and power regulation and by the Central Coordinating System for automatic frequency and power regulation is presented. The results of full-scale system tests ofmore » the control of power generating units of the Kirishskaya, Stavropol, and Perm GRES (State Regional Electric Power Plants) by the Central Coordinating System for automatic frequency and power regulation at the United Power System of Russia on September 23-25, 2008, are reported.« less
Real-time feedback control of twin-screw wet granulation based on image analysis.
Madarász, Lajos; Nagy, Zsombor Kristóf; Hoffer, István; Szabó, Barnabás; Csontos, István; Pataki, Hajnalka; Démuth, Balázs; Szabó, Bence; Csorba, Kristóf; Marosi, György
2018-06-04
The present paper reports the first dynamic image analysis-based feedback control of continuous twin-screw wet granulation process. Granulation of the blend of lactose and starch was selected as a model process. The size and size distribution of the obtained particles were successfully monitored by a process camera coupled with an image analysis software developed by the authors. The validation of the developed system showed that the particle size analysis tool can determine the size of the granules with an error of less than 5 µm. The next step was to implement real-time feedback control of the process by controlling the liquid feeding rate of the pump through a PC, based on the real-time determined particle size results. After the establishment of the feedback control, the system could correct different real-life disturbances, creating a Process Analytically Controlled Technology (PACT), which guarantees the real-time monitoring and controlling of the quality of the granules. In the event of changes or bad tendencies in the particle size, the system can automatically compensate the effect of disturbances, ensuring proper product quality. This kind of quality assurance approach is especially important in the case of continuous pharmaceutical technologies. Copyright © 2018 Elsevier B.V. All rights reserved.
Purge- and intensive-purge decontamination of dental units contaminated with biofilm
Kramer, Axel; Assadian, Ojan; Bachfeld, Danny; Meyer, Georg
2012-01-01
Introduction: During hygienic-microbiological monitoring of the water quality in dental units, the total bacterial colony count was found to exceed the limits for drinking water quality; in addition, mold contamination was detected. The presumed cause was irregular decontamination of the units through purging and intensive decontamination. Methods: To decontaminate the units, the manufacturer’s recommended program for cleaning and intensive decontamination was intensified by shortened intervals over a 2-week period. For Sirona units, instead of once a day, the automatic purge program was run every morning and evening for 20 min each time, and instead of once a month, intensive decontamination was performed every two weeks; this schedule has been maintained since then. For KaVo units, cleaning with the hydroclean function was carried out for 2.5 min every morning and evening. The automatic intensive decontamination was run daily instead of weekly. A maintenance log book was introduced, in which decontamination/cleaning was confirmed by the operator’s signature. Results: Within 5 weeks, all previously contaminated units were decontaminated. Discussion: By shortening the cleaning and intensive decontamination intervals in a 2-week period with subsequent control that the recommended maintenance intervals were kept, it was possible to guarantee drinking-water quality in the dental units of both manufacturers. PMID:22558045
Subminiature eddy-current transducers designed to study welded joints of titanium alloys
NASA Astrophysics Data System (ADS)
Malikov, V. N.; Dmitriev, S. F.; Katasonov, A. O.; Sagalakov, A. M.; Ishkov, A. V.
2017-12-01
Eddy current transducers (ECT) are used to construct a sensor for investigating titanium sheets connected by a welded joint. The paper provides key technical information about the eddy current transducer used and describes the procedure of measurements that makes it possible to control defects in welded joints of titanium alloys. It is capable of automatically changing the filtering cutoff frequency and operating frequency of the device. Experiments were conducted on welded VT1-0 titanium plates. The paper contains the results of these measurements. The dependence data facilitates the assessment of the quality of the welded joints and helps make an educated conclusion about welding quality.
Automatic assessment of the quality of patient positioning in mammography
NASA Astrophysics Data System (ADS)
Bülow, Thomas; Meetz, Kirsten; Kutra, Dominik; Netsch, Thomas; Wiemker, Rafael; Bergtholdt, Martin; Sabczynski, Jörg; Wieberneit, Nataly; Freund, Manuela; Schulze-Wenck, Ingrid
2013-02-01
Quality assurance has been recognized as crucial for the success of population-based breast cancer screening programs using x-ray mammography. Quality guidelines and criteria have been defined in the US as well as the European Union in order to ensure the quality of breast cancer screening. Taplin et al. report that incorrect positioning of the breast is the major image quality issue in screening mammography. Consequently, guidelines and criteria for correct positioning and for the assessment of the positioning quality in mammograms play an important role in the quality standards. In this paper we present a system for the automatic evaluation of positioning quality in mammography according to the existing standardized criteria. This involves the automatic detection of anatomic landmarks in medio- lateral oblique (MLO) and cranio-caudal (CC) mammograms, namely the pectoral muscle, the mammilla and the infra-mammary fold. Furthermore, the detected landmarks are assessed with respect to their proper presentation in the image. Finally, the geometric relations between the detected landmarks are investigated to assess the positioning quality. This includes the evaluation whether the pectoral muscle is imaged down to the mammilla level, and whether the posterior nipple line diameter of the breast is consistent between the different views (MLO and CC) of the same breast. Results of the computerized assessment are compared to ground truth collected from two expert readers.
NASA Astrophysics Data System (ADS)
Rzonca, A.
2013-12-01
The paper presents the state of the art of quality control of photogrammetric and laser scanning data captured by airborne sensors. The described subject is very important for photogrammetric and LiDAR project execution, because the data quality a prior decides about the final product quality. On the other hand, precise and effective quality control process allows to execute the missions without wide margin of safety, especially in case of the mountain areas projects. For introduction, the author presents theoretical background of the quality control, basing on his own experience, instructions and technical documentation. He describes several variants of organization solutions. Basically, there are two main approaches: quality control of the captured data and the control of discrepancies of the flight plan and its results of its execution. Both of them are able to use test of control and analysis of the data. The test is an automatic algorithm controlling the data and generating the control report. Analysis is a less complicated process, that is based on documentation, data and metadata manual check. The example of quality control system for large area project was presented. The project is being realized periodically for the territory of all Spain and named National Plan of Aerial Orthophotography (Plan Nacional de Ortofotografía Aérea, PNOA). The system of the internal control guarantees its results soon after the flight and informs the flight team of the company. It allows to correct all the errors shortly after the flight and it might stop transferring the data to another team or company, for further data processing. The described system of data quality control contains geometrical and radiometrical control of photogrammetric data and geometrical control of LiDAR data. According to all specified parameters, it checks all of them and generates the reports. They are very helpful in case of some errors or low quality data. The paper includes the author experience in the field of data quality control, presents the conclusions and suggestions of the organization and technical aspects, with a short definition of the necessary control software.
Effects of voluntary and automatic control of center of pressure sway during quiet standing.
Ueta, Kozo; Okada, Yohei; Nakano, Hideki; Osumi, Michihiro; Morioka, Shu
2015-01-01
The authors investigated the effects of voluntary and automatic control on the spatial variables (envelope area, maximal amplitude, and root mean square [RMS]) of center of pressure (COP) displacement during quiet standing and identified differences in their postural control strategies (mean velocity [MV], mean power frequency [MPF], and power density). COP data were recorded under relaxed (experimental control), still (voluntary control), and dual (automatic control) conditions. RMS was significantly lower in the still and dual conditions than in the relaxed condition. MV, MPF, and power density were significantly higher in the still condition than in the dual condition. These results indicate that both voluntary and automatic control decrease the spatial variables of COP displacement; however, their postural control strategies are different.
14 CFR Appendix I to Part 25 - Installation of an Automatic Takeoff Thrust Control System (ATTCS)
Code of Federal Regulations, 2011 CFR
2011-01-01
... Appendix I to Part 25—Installation of an Automatic Takeoff Thrust Control System (ATTCS) I25.1General. (a... crew to increase thrust or power. I25.2Definitions. (a) Automatic Takeoff Thrust Control System (ATTCS... Control System (ATTCS) I Appendix I to Part 25 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION...
Moore, C S; Wood, T J; Avery, G; Balcam, S; Needler, L; Beavis, A W; Saunderson, J R
2014-05-07
The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean effective noise equivalent quanta (eNEQm), all measured using a uniform chest phantom. Subsequent calibration curves were derived to ensure each metric was held constant across the tube voltage range. Each curve was assessed for its clinical appropriateness by generating computer simulated chest images with correct detector air kermas for each tube voltage, and grading these against reference images which were reconstructed at detector air kermas correct for the constant detector dose indicator (DDI) curve currently programmed into the AEC device. All simulated chest images contained clinically realistic projected anatomy and anatomical noise and were scored by experienced image evaluators. Constant DDI and CNR curves do not appear to provide optimized performance across the diagnostic energy range. Conversely, constant eNEQm and SNR do appear to provide optimized performance, with the latter being the preferred calibration metric given as it is easier to measure in practice. Medical physicists may use the SNR image quality metric described here when setting up and optimizing AEC devices for chest radiography CR systems with a degree of confidence that resulting clinical image quality will be adequate for the required clinical task. However, this must be done with close cooperation of expert image evaluators, to ensure appropriate levels of detector air kerma.
NASA Astrophysics Data System (ADS)
Moore, C. S.; Wood, T. J.; Avery, G.; Balcam, S.; Needler, L.; Beavis, A. W.; Saunderson, J. R.
2014-05-01
The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean effective noise equivalent quanta (eNEQm), all measured using a uniform chest phantom. Subsequent calibration curves were derived to ensure each metric was held constant across the tube voltage range. Each curve was assessed for its clinical appropriateness by generating computer simulated chest images with correct detector air kermas for each tube voltage, and grading these against reference images which were reconstructed at detector air kermas correct for the constant detector dose indicator (DDI) curve currently programmed into the AEC device. All simulated chest images contained clinically realistic projected anatomy and anatomical noise and were scored by experienced image evaluators. Constant DDI and CNR curves do not appear to provide optimized performance across the diagnostic energy range. Conversely, constant eNEQm and SNR do appear to provide optimized performance, with the latter being the preferred calibration metric given as it is easier to measure in practice. Medical physicists may use the SNR image quality metric described here when setting up and optimizing AEC devices for chest radiography CR systems with a degree of confidence that resulting clinical image quality will be adequate for the required clinical task. However, this must be done with close cooperation of expert image evaluators, to ensure appropriate levels of detector air kerma.
Lv, Peijie; Liu, Jie; Zhang, Rui; Jia, Yan
2015-01-01
Objective To assess the lesion conspicuity and image quality in CT evaluation of small (≤ 3 cm) hepatocellular carcinomas (HCCs) using automatic tube voltage selection (ATVS) and automatic tube current modulation (ATCM) with or without iterative reconstruction. Materials and Methods One hundred and five patients with 123 HCC lesions were included. Fifty-seven patients were scanned using both ATVS and ATCM and images were reconstructed using either filtered back-projection (FBP) (group A1) or sinogram-affirmed iterative reconstruction (SAFIRE) (group A2). Forty-eight patients were imaged using only ATCM, with a fixed tube potential of 120 kVp and FBP reconstruction (group B). Quantitative parameters (image noise in Hounsfield unit and contrast-to-noise ratio of the aorta, the liver, and the hepatic tumors) and qualitative visual parameters (image noise, overall image quality, and lesion conspicuity as graded on a 5-point scale) were compared among the groups. Results Group A2 scanned with the automatically chosen 80 kVp and 100 kVp tube voltages ranked the best in lesion conspicuity and subjective and objective image quality (p values ranging from < 0.001 to 0.004) among the three groups, except for overall image quality between group A2 and group B (p = 0.022). Group A1 showed higher image noise (p = 0.005) but similar lesion conspicuity and overall image quality as compared with group B. The radiation dose in group A was 19% lower than that in group B (p = 0.022). Conclusion CT scanning with combined use of ATVS and ATCM and image reconstruction with SAFIRE algorithm provides higher lesion conspicuity and better image quality for evaluating small hepatic HCCs with radiation dose reduction. PMID:25995682
Proteomics Quality Control: Quality Control Software for MaxQuant Results.
Bielow, Chris; Mastrobuoni, Guido; Kempa, Stefan
2016-03-04
Mass spectrometry-based proteomics coupled to liquid chromatography has matured into an automatized, high-throughput technology, producing data on the scale of multiple gigabytes per instrument per day. Consequently, an automated quality control (QC) and quality analysis (QA) capable of detecting measurement bias, verifying consistency, and avoiding propagation of error is paramount for instrument operators and scientists in charge of downstream analysis. We have developed an R-based QC pipeline called Proteomics Quality Control (PTXQC) for bottom-up LC-MS data generated by the MaxQuant software pipeline. PTXQC creates a QC report containing a comprehensive and powerful set of QC metrics, augmented with automated scoring functions. The automated scores are collated to create an overview heatmap at the beginning of the report, giving valuable guidance also to nonspecialists. Our software supports a wide range of experimental designs, including stable isotope labeling by amino acids in cell culture (SILAC), tandem mass tags (TMT), and label-free data. Furthermore, we introduce new metrics to score MaxQuant's Match-between-runs (MBR) functionality by which peptide identifications can be transferred across Raw files based on accurate retention time and m/z. Last but not least, PTXQC is easy to install and use and represents the first QC software capable of processing MaxQuant result tables. PTXQC is freely available at https://github.com/cbielow/PTXQC .
Culture, attribution and automaticity: a social cognitive neuroscience view
Morris, Michael W.
2010-01-01
A fundamental challenge facing social perceivers is identifying the cause underlying other people’s behavior. Evidence indicates that East Asian perceivers are more likely than Western perceivers to reference the social context when attributing a cause to a target person’s actions. One outstanding question is whether this reflects a culture’s influence on automatic or on controlled components of causal attribution. After reviewing behavioral evidence that culture can shape automatic mental processes as well as controlled reasoning, we discuss the evidence in favor of cultural differences in automatic and controlled components of causal attribution more specifically. We contend that insights emerging from social cognitive neuroscience research can inform this debate. After introducing an attribution framework popular among social neuroscientists, we consider findings relevant to the automaticity of attribution, before speculating how one could use a social neuroscience approach to clarify whether culture affects automatic, controlled or both types of attribution processes. PMID:20460302
NASA Astrophysics Data System (ADS)
Wesemann, Johannes; Burgholzer, Reinhard; Herrnegger, Mathew; Schulz, Karsten
2017-04-01
In recent years, a lot of research in hydrological modelling has been invested to improve the automatic calibration of rainfall-runoff models. This includes for example (1) the implementation of new optimisation methods, (2) the incorporation of new and different objective criteria and signatures in the optimisation and (3) the usage of auxiliary data sets apart from runoff. Nevertheless, in many applications manual calibration is still justifiable and frequently applied. The hydrologist performing the manual calibration, with his expert knowledge, is able to judge the hydrographs simultaneously concerning details but also in a holistic view. This integrated eye-ball verification procedure available to man can be difficult to formulate in objective criteria, even when using a multi-criteria approach. Comparing the results of automatic and manual calibration is not straightforward. Automatic calibration often solely involves objective criteria such as Nash-Sutcliffe Efficiency Coefficient or the Kling-Gupta-Efficiency as a benchmark during the calibration. Consequently, a comparison based on such measures is intrinsically biased towards automatic calibration. Additionally, objective criteria do not cover all aspects of a hydrograph leaving questions concerning the quality of a simulation open. This contribution therefore seeks to examine the quality of manually and automatically calibrated hydrographs by interactively involving expert knowledge in the evaluation. Simulations have been performed for the Mur catchment in Austria with the rainfall-runoff model COSERO using two parameter sets evolved from a manual and an automatic calibration. A subset of resulting hydrographs for observation and simulation, representing the typical flow conditions and events, will be evaluated in this study. In an interactive crowdsourcing approach experts attending the session can vote for their preferred simulated hydrograph without having information on the calibration method that produced the respective hydrograph. Therefore, the result of the poll can be seen as an additional quality criterion for the comparison of the two different approaches and help in the evaluation of the automatic calibration method.
Power-Constrained Fuzzy Logic Control of Video Streaming over a Wireless Interconnect
NASA Astrophysics Data System (ADS)
Razavi, Rouzbeh; Fleury, Martin; Ghanbari, Mohammed
2008-12-01
Wireless communication of video, with Bluetooth as an example, represents a compromise between channel conditions, display and decode deadlines, and energy constraints. This paper proposes fuzzy logic control (FLC) of automatic repeat request (ARQ) as a way of reconciling these factors, with a 40% saving in power in the worst channel conditions from economizing on transmissions when channel errors occur. Whatever the channel conditions are, FLC is shown to outperform the default Bluetooth scheme and an alternative Bluetooth-adaptive ARQ scheme in terms of reduced packet loss and delay, as well as improved video quality.
A routine quality assurance test for CT automatic exposure control systems.
Iball, Gareth R; Moore, Alexis C; Crawford, Elizabeth J
2016-07-08
The study purpose was to develop and validate a quality assurance test for CT automatic exposure control (AEC) systems based on a set of nested polymethylmethacrylate CTDI phantoms. The test phantom was created by offsetting the 16 cm head phantom within the 32 cm body annulus, thus creating a three part phantom. This was scanned at all acceptance, routine, and some nonroutine quality assurance visits over a period of 45 months, resulting in 115 separate AEC tests on scanners from four manufacturers. For each scan the longitudinal mA modulation pattern was generated and measurements of image noise were made in two annular regions of interest. The scanner displayed CTDIvol and DLP were also recorded. The impact of a range of AEC configurations on dose and image quality were assessed at acceptance testing. For systems that were tested more than once, the percentage of CTDIvol values exceeding 5%, 10%, and 15% deviation from baseline was 23.4%, 12.6%, and 8.1% respectively. Similarly, for the image noise data, deviations greater than 2%, 5%, and 10% from baseline were 26.5%, 5.9%, and 2%, respectively. The majority of CTDIvol and noise deviations greater than 15% and 5%, respectively, could be explained by incorrect phantom setup or protocol selection. Barring these results, CTDIvol deviations of greater than 15% from baseline were found in 0.9% of tests and noise deviations greater than 5% from baseline were found in 1% of tests. The phantom was shown to be sensitive to changes in AEC setup, including the use of 3D, longitudinal or rotational tube current modulation. This test methodology allows for continuing performance assessment of CT AEC systems, and we recommend that this test should become part of routine CT quality assurance programs. Tolerances of ± 15% for CTDIvol and ± 5% for image noise relative to baseline values should be used. © 2016 The Authors
Crowdsourcing for error detection in cortical surface delineations.
Ganz, Melanie; Kondermann, Daniel; Andrulis, Jonas; Knudsen, Gitte Moos; Maier-Hein, Lena
2017-01-01
With the recent trend toward big data analysis, neuroimaging datasets have grown substantially in the past years. While larger datasets potentially offer important insights for medical research, one major bottleneck is the requirement for resources of medical experts needed to validate automatic processing results. To address this issue, the goal of this paper was to assess whether anonymous nonexperts from an online community can perform quality control of MR-based cortical surface delineations derived by an automatic algorithm. So-called knowledge workers from an online crowdsourcing platform were asked to annotate errors in automatic cortical surface delineations on 100 central, coronal slices of MR images. On average, annotations for 100 images were obtained in less than an hour. When using expert annotations as reference, the crowd on average achieves a sensitivity of 82 % and a precision of 42 %. Merging multiple annotations per image significantly improves the sensitivity of the crowd (up to 95 %), but leads to a decrease in precision (as low as 22 %). Our experiments show that the detection of errors in automatic cortical surface delineations generated by anonymous untrained workers is feasible. Future work will focus on increasing the sensitivity of our method further, such that the error detection tasks can be handled exclusively by the crowd and expert resources can be focused on error correction.
NASA Astrophysics Data System (ADS)
Knox, H. A.; Draelos, T.; Young, C. J.; Lawry, B.; Chael, E. P.; Faust, A.; Peterson, M. G.
2015-12-01
The quality of automatic detections from seismic sensor networks depends on a large number of data processing parameters that interact in complex ways. The largely manual process of identifying effective parameters is painstaking and does not guarantee that the resulting controls are the optimal configuration settings. Yet, achieving superior automatic detection of seismic events is closely related to these parameters. We present an automated sensor tuning (AST) system that learns near-optimal parameter settings for each event type using neuro-dynamic programming (reinforcement learning) trained with historic data. AST learns to test the raw signal against all event-settings and automatically self-tunes to an emerging event in real-time. The overall goal is to reduce the number of missed legitimate event detections and the number of false event detections. Reducing false alarms early in the seismic pipeline processing will have a significant impact on this goal. Applicable both for existing sensor performance boosting and new sensor deployment, this system provides an important new method to automatically tune complex remote sensing systems. Systems tuned in this way will achieve better performance than is currently possible by manual tuning, and with much less time and effort devoted to the tuning process. With ground truth on detections in seismic waveforms from a network of stations, we show that AST increases the probability of detection while decreasing false alarms.
[Automation of chemical analysis in enology].
Dubernet, M
1978-01-01
Automatic dosages took place a short time ago in oenology laboratories. First researchs about automation of usual manual analysis have been completed by I.N.R.A. Station of Dijon during 1969--1972 years. Then, other researchs were made and in 1974 the first automatic analyser appeared in application laboratories. In all cases continuous flow method was used. First dosages which has been carried out are volatic acidity, residual sugars, total SO2. The rate of work is 30 samples an hour. Then, an original way for free SO2 was suggested. At present, about a dozen of laboratories in France use these dosages. The ethanol dosage automation, very important in oenology, is very difficult to carry out. A new method using a thermometric analyzer is tested. Research about many dosages as tartaric, malic, lactic acids, glucose, fructose, glycérol, have been performed especially by I.N.R.A. Station in Narbonne. But these dosages are not current and at present no laboratory apply them. Now, equipments price and redemption, change of tradionnal dosages for automatical methods and the level of knowledge required for operators are well known. The reproducibility and the accuracy of the continuous flow automatic dosages allow, for enough important laboratories, to make an increasing number of analysis necessary for wine quality control.
Direction of the Rational Use of Water at the Facilities for Growing Poultry
NASA Astrophysics Data System (ADS)
Potseluev, A. A.; Nazarov, I. V.; Porotkova, A. K.; Volovikova, N. V.
2018-01-01
The article notes the effect of water use in the technological process of automatic drinking agricultural poultry on the quality and the quantity of outputs. At the same time, the requirements to the quality of the used water, the regimes of its consumption by the poultry and the role of mechanization of the process of automatic drinking in the rational use of the water resource, the processing and the reuse of contaminated wastes are disclosed. Within the framework of this concept, we propose constructively technological solutions of systems and means of automatic drinking agricultural poultry, providing the rational use of water as one of the important products of vital activity of agricultural poultry.
HOLA: Human-like Orthogonal Network Layout.
Kieffer, Steve; Dwyer, Tim; Marriott, Kim; Wybrow, Michael
2016-01-01
Over the last 50 years a wide variety of automatic network layout algorithms have been developed. Some are fast heuristic techniques suitable for networks with hundreds of thousands of nodes while others are multi-stage frameworks for higher-quality layout of smaller networks. However, despite decades of research currently no algorithm produces layout of comparable quality to that of a human. We give a new "human-centred" methodology for automatic network layout algorithm design that is intended to overcome this deficiency. User studies are first used to identify the aesthetic criteria algorithms should encode, then an algorithm is developed that is informed by these criteria and finally, a follow-up study evaluates the algorithm output. We have used this new methodology to develop an automatic orthogonal network layout method, HOLA, that achieves measurably better (by user study) layout than the best available orthogonal layout algorithm and which produces layouts of comparable quality to those produced by hand.
Kim, Heejun; Bian, Jiantao; Mostafa, Javed; Jonnalagadda, Siddhartha; Del Fiol, Guilherme
2016-01-01
Motivation: Clinicians need up-to-date evidence from high quality clinical trials to support clinical decisions. However, applying evidence from the primary literature requires significant effort. Objective: To examine the feasibility of automatically extracting key clinical trial information from ClinicalTrials.gov. Methods: We assessed the coverage of ClinicalTrials.gov for high quality clinical studies that are indexed in PubMed. Using 140 random ClinicalTrials.gov records, we developed and tested rules for the automatic extraction of key information. Results: The rate of high quality clinical trial registration in ClinicalTrials.gov increased from 0.2% in 2005 to 17% in 2015. Trials reporting results increased from 3% in 2005 to 19% in 2015. The accuracy of the automatic extraction algorithm for 10 trial attributes was 90% on average. Future research is needed to improve the algorithm accuracy and to design information displays to optimally present trial information to clinicians.
Testing methods and techniques: Testing electrical and electronic devices: A compilation
NASA Technical Reports Server (NTRS)
1972-01-01
The methods, techniques, and devices used in testing various electrical and electronic apparatus are presented. The items described range from semiconductor package leak detectors to automatic circuit analyzer and antenna simulators for system checkout. In many cases the approaches can result in considerable cost savings and improved quality control. The testing of various electronic components, assemblies, and systems; the testing of various electrical devices; and the testing of cables and connectors are explained.
Software engineering project management - A state-of-the-art report
NASA Technical Reports Server (NTRS)
Thayer, R. H.; Lehman, J. H.
1977-01-01
The management of software engineering projects in the aerospace industry was investigated. The survey assessed such features as contract type, specification preparation techniques, software documentation required by customers, planning and cost-estimating, quality control, the use of advanced program practices, software tools and test procedures, the education levels of project managers, programmers and analysts, work assignment, automatic software monitoring capabilities, design and coding reviews, production times, success rates, and organizational structure of the projects.
Semi-automatic semantic annotation of PubMed Queries: a study on quality, efficiency, satisfaction
Névéol, Aurélie; Islamaj-Doğan, Rezarta; Lu, Zhiyong
2010-01-01
Information processing algorithms require significant amounts of annotated data for training and testing. The availability of such data is often hindered by the complexity and high cost of production. In this paper, we investigate the benefits of a state-of-the-art tool to help with the semantic annotation of a large set of biomedical information queries. Seven annotators were recruited to annotate a set of 10,000 PubMed® queries with 16 biomedical and bibliographic categories. About half of the queries were annotated from scratch, while the other half were automatically pre-annotated and manually corrected. The impact of the automatic pre-annotations was assessed on several aspects of the task: time, number of actions, annotator satisfaction, inter-annotator agreement, quality and number of the resulting annotations. The analysis of annotation results showed that the number of required hand annotations is 28.9% less when using pre-annotated results from automatic tools. As a result, the overall annotation time was substantially lower when pre-annotations were used, while inter-annotator agreement was significantly higher. In addition, there was no statistically significant difference in the semantic distribution or number of annotations produced when pre-annotations were used. The annotated query corpus is freely available to the research community. This study shows that automatic pre-annotations are found helpful by most annotators. Our experience suggests using an automatic tool to assist large-scale manual annotation projects. This helps speed-up the annotation time and improve annotation consistency while maintaining high quality of the final annotations. PMID:21094696
Synthesis of the unmanned aerial vehicle remote control augmentation system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tomczyk, Andrzej, E-mail: A.Tomczyk@prz.edu.pl
Medium size Unmanned Aerial Vehicle (UAV) usually flies as an autonomous aircraft including automatic take-off and landing phases. However in the case of the on-board control system failure, the remote steering is using as an emergency procedure. In this reason, remote manual control of unmanned aerial vehicle is used more often during take-of and landing phases. Depends on UAV take-off mass and speed (total energy) the potential crash can be very danger for airplane and environment. So, handling qualities of UAV is important from pilot-operator point of view. In many cases the dynamic properties of remote controlling UAV are notmore » suitable for obtaining the desired properties of the handling qualities. In this case the control augmentation system (CAS) should be applied. Because the potential failure of the on-board control system, the better solution is that the CAS algorithms are placed on the ground station computers. The method of UAV handling qualities shaping in the case of basic control system failure is presented in this paper. The main idea of this method is that UAV reaction on the operator steering signals should be similar - almost the same - as reaction of the 'ideal' remote control aircraft. The model following method was used for controller parameters calculations. The numerical example concerns the medium size MP-02A UAV applied as an aerial observer system.« less
Doescher, A; Loges, U; Petershofen, E K; Müller, T H
2017-11-01
Enumeration of residual white blood cells in leucoreduced blood components is essential part of quality control. Digital PCR has substantially facilitated quantitative PCR and was thus evaluated for measurements of leucocytes. Target for quantification of leucocytes by digital droplet PCR was the blood group gene RHCE. The SPEF1 gene was added as internal control for the entire assay starting with automated DNA extraction. The sensitivity of the method was determined by serial dilutions of standard samples. Quality control samples were analysed within 24 h, 7 days and 6 months after collection. Routine samples from leucodepleted red blood cell concentrates (n = 150) were evaluated in parallel by flow-cytometry (LeucoCount) and by digital PCR. Digital PCR reliably detected at least 0·4 leucocytes per assay. The mean difference between PCR and flow-cytometric results from 150 units was -0·01 (±1·0). DNA samples were stable for up to at least six months. PCR measurement of leucocytes in samples from plasma and platelet concentrates also provided valid results in a pilot study. Droplet digital PCR to enumerate leucocytes offers an alternative for quality control of leucoreduced blood products. Sensitivity, specificity and reproducibility are comparable to flow-cytometry. The option to collect samples over an extended period of time and the automatization introduce attractive features for routine quality control. © 2017 International Society of Blood Transfusion.
Automated daily quality control analysis for mammography in a multi-unit imaging center.
Sundell, Veli-Matti; Mäkelä, Teemu; Meaney, Alexander; Kaasalainen, Touko; Savolainen, Sauli
2018-01-01
Background The high requirements for mammography image quality necessitate a systematic quality assurance process. Digital imaging allows automation of the image quality analysis, which can potentially improve repeatability and objectivity compared to a visual evaluation made by the users. Purpose To develop an automatic image quality analysis software for daily mammography quality control in a multi-unit imaging center. Material and Methods An automated image quality analysis software using the discrete wavelet transform and multiresolution analysis was developed for the American College of Radiology accreditation phantom. The software was validated by analyzing 60 randomly selected phantom images from six mammography systems and 20 phantom images with different dose levels from one mammography system. The results were compared to a visual analysis made by four reviewers. Additionally, long-term image quality trends of a full-field digital mammography system and a computed radiography mammography system were investigated. Results The automated software produced feature detection levels comparable to visual analysis. The agreement was good in the case of fibers, while the software detected somewhat more microcalcifications and characteristic masses. Long-term follow-up via a quality assurance web portal demonstrated the feasibility of using the software for monitoring the performance of mammography systems in a multi-unit imaging center. Conclusion Automated image quality analysis enables monitoring the performance of digital mammography systems in an efficient, centralized manner.
Automatic control of solar power plants
NASA Astrophysics Data System (ADS)
Ermakov, V. S.; Dubilovich, V. M.
1982-02-01
The automatic control of the heliostat field of a 200-MW solar power plant is discussed. The advantages of the decentralized control principle with the solution of a number of individual problems in a single control center are emphasized. The basic requirements on heliostat construction are examined, and possible functional schemes for the automatic control of a heliostat field are described. It is proposed that groups of heliostats can be controlled from a single center and on the basis of a single algorithm.
46 CFR 61.30-20 - Automatic control and safety tests.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Automatic control and safety tests. 61.30-20 Section 61.30-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND INSPECTIONS Tests and Inspections of Fired Thermal Fluid Heaters § 61.30-20 Automatic control and safety tests. Operational tests and check...
Automatic glaucoma diagnosis through medical imaging informatics.
Liu, Jiang; Zhang, Zhuo; Wong, Damon Wing Kee; Xu, Yanwu; Yin, Fengshou; Cheng, Jun; Tan, Ngan Meng; Kwoh, Chee Keong; Xu, Dong; Tham, Yih Chung; Aung, Tin; Wong, Tien Yin
2013-01-01
Computer-aided diagnosis for screening utilizes computer-based analytical methodologies to process patient information. Glaucoma is the leading irreversible cause of blindness. Due to the lack of an effective and standard screening practice, more than 50% of the cases are undiagnosed, which prevents the early treatment of the disease. To design an automatic glaucoma diagnosis architecture automatic glaucoma diagnosis through medical imaging informatics (AGLAIA-MII) that combines patient personal data, medical retinal fundus image, and patient's genome information for screening. 2258 cases from a population study were used to evaluate the screening software. These cases were attributed with patient personal data, retinal images and quality controlled genome data. Utilizing the multiple kernel learning-based classifier, AGLAIA-MII, combined patient personal data, major image features, and important genome single nucleotide polymorphism (SNP) features. Receiver operating characteristic curves were plotted to compare AGLAIA-MII's performance with classifiers using patient personal data, images, and genome SNP separately. AGLAIA-MII was able to achieve an area under curve value of 0.866, better than 0.551, 0.722 and 0.810 by the individual personal data, image and genome information components, respectively. AGLAIA-MII also demonstrated a substantial improvement over the current glaucoma screening approach based on intraocular pressure. AGLAIA-MII demonstrates for the first time the capability of integrating patients' personal data, medical retinal image and genome information for automatic glaucoma diagnosis and screening in a large dataset from a population study. It paves the way for a holistic approach for automatic objective glaucoma diagnosis and screening.
NASA Astrophysics Data System (ADS)
Takemine, S.; Rikimaru, A.; Takahashi, K.
The rice is one of the staple foods in the world High quality rice production requires periodically collecting rice growth data to control the growth of rice The height of plant the number of stem the color of leaf is well known parameters to indicate rice growth Rice growth diagnosis method based on these parameters is used operationally in Japan although collecting these parameters by field survey needs a lot of labor and time Recently a laborsaving method for rice growth diagnosis is proposed which is based on vegetation cover rate of rice Vegetation cover rate of rice is calculated based on discriminating rice plant areas in a digital camera image which is photographed in nadir direction Discrimination of rice plant areas in the image was done by the automatic binarization processing However in the case of vegetation cover rate calculation method depending on the automatic binarization process there is a possibility to decrease vegetation cover rate against growth of rice In this paper a calculation method of vegetation cover rate was proposed which based on the automatic binarization process and referred to the growth hysteresis information For several images obtained by field survey during rice growing season vegetation cover rate was calculated by the conventional automatic binarization processing and the proposed method respectively And vegetation cover rate of both methods was compared with reference value obtained by visual interpretation As a result of comparison the accuracy of discriminating rice plant areas was increased by the proposed
An Automatic Quality Control Pipeline for High-Throughput Screening Hit Identification.
Zhai, Yufeng; Chen, Kaisheng; Zhong, Yang; Zhou, Bin; Ainscow, Edward; Wu, Ying-Ta; Zhou, Yingyao
2016-09-01
The correction or removal of signal errors in high-throughput screening (HTS) data is critical to the identification of high-quality lead candidates. Although a number of strategies have been previously developed to correct systematic errors and to remove screening artifacts, they are not universally effective and still require fair amount of human intervention. We introduce a fully automated quality control (QC) pipeline that can correct generic interplate systematic errors and remove intraplate random artifacts. The new pipeline was first applied to ~100 large-scale historical HTS assays; in silico analysis showed auto-QC led to a noticeably stronger structure-activity relationship. The method was further tested in several independent HTS runs, where QC results were sampled for experimental validation. Significantly increased hit confirmation rates were obtained after the QC steps, confirming that the proposed method was effective in enriching true-positive hits. An implementation of the algorithm is available to the screening community. © 2016 Society for Laboratory Automation and Screening.
NASA Technical Reports Server (NTRS)
1989-01-01
001 is an integrated tool suited for automatically developing ultra reliable models, simulations and software systems. Developed and marketed by Hamilton Technologies, Inc. (HTI), it has been applied in engineering, manufacturing, banking and software tools development. The software provides the ability to simplify the complex. A system developed with 001 can be a prototype or fully developed with production quality code. It is free of interface errors, consistent, logically complete and has no data or control flow errors. Systems can be designed, developed and maintained with maximum productivity. Margaret Hamilton, President of Hamilton Technologies, also directed the research and development of USE.IT, an earlier product which was the first computer aided software engineering product in the industry to concentrate on automatically supporting the development of an ultrareliable system throughout its life cycle. Both products originated in NASA technology developed under a Johnson Space Center contract.
Intended actions and unexpected outcomes: automatic and controlled processing in a rapid motor task
Cheyne, Douglas O.; Ferrari, Paul; Cheyne, James A.
2012-01-01
Human action involves a combination of controlled and automatic behavior. These processes may interact in tasks requiring rapid response selection or inhibition, where temporal constraints preclude timely intervention by conscious, controlled processes over automatized prepotent responses. Such contexts tend to produce frequent errors, but also rapidly executed correct responses, both of which may sometimes be perceived as surprising, unintended, or “automatic”. In order to identify neural processes underlying these two aspects of cognitive control, we measured neuromagnetic brain activity in 12 right-handed subjects during manual responses to rapidly presented digits, with an infrequent target digit that required switching response hand (bimanual task) or response finger (unimanual task). Automaticity of responding was evidenced by response speeding (shorter response times) prior to both failed and fast correct switches. Consistent with this automaticity interpretation of fast correct switches, we observed bilateral motor preparation, as indexed by suppression of beta band (15–30 Hz) oscillations in motor cortex, prior to processing of the switch cue in the bimanual task. In contrast, right frontal theta activity (4–8 Hz) accompanying correct switch responses began after cue onset, suggesting that it reflected controlled inhibition of the default response. Further, this activity was reduced on fast correct switch trials suggesting a more automatic mode of inhibitory control. We also observed post-movement (event-related negativity) ERN-like responses and theta band increases in medial and anterior frontal regions that were significantly larger on error trials, and may reflect a combination of error and delayed inhibitory signals. We conclude that both automatic and controlled processes are engaged in parallel during rapid motor tasks, and that the relative strength and timing of these processes may underlie both optimal task performance and subjective experiences of automaticity or control. PMID:22912612
NASA Technical Reports Server (NTRS)
Barthlome, D. E.
1975-01-01
Test results of a unique automatic brake control system are outlined and a comparison is made of its mode of operation to that of an existing skid control system. The purpose of the test system is to provide automatic control of braking action such that hydraulic brake pressure is maintained at a near constant, optimum value during minimum distance stops.
Investigation of an automatic trim algorithm for restructurable aircraft control
NASA Technical Reports Server (NTRS)
Weiss, J.; Eterno, J.; Grunberg, D.; Looze, D.; Ostroff, A.
1986-01-01
This paper develops and solves an automatic trim problem for restructurable aircraft control. The trim solution is applied as a feed-forward control to reject measurable disturbances following control element failures. Disturbance rejection and command following performances are recovered through the automatic feedback control redesign procedure described by Looze et al. (1985). For this project the existence of a failure detection mechanism is assumed, and methods to cope with potential detection and identification inaccuracies are addressed.
To do it or to let an automatic tool do it? The priority of control over effort.
Osiurak, François; Wagner, Clara; Djerbi, Sara; Navarro, Jordan
2013-01-01
The aim of the present study is to provide experimental data relevant to the issue of what leads humans to use automatic tools. Two answers can be offered. The first is that humans strive to minimize physical and/or cognitive effort (principle of least effort). The second is that humans tend to keep their perceived control over the environment (principle of more control). These two factors certainly play a role, but the question raised here is to what do people give priority in situations wherein both manual and automatic actions take the same time - minimizing effort or keeping perceived control? To answer that question, we built four experiments in which participants were confronted with a recurring choice between performing a task manually (physical effort) or in a semi-automatic way (cognitive effort) versus using an automatic tool that completes the task for them (no effort). In this latter condition, participants were required to follow the progression of the automatic tool step by step. Our results showed that participants favored the manual or semi-automatic condition over the automatic condition. However, when they were offered the opportunity to perform recreational tasks in parallel, the shift toward manual condition disappeared. The findings give support to the idea that people give priority to keeping control over minimizing effort.
NASA Technical Reports Server (NTRS)
Dejesusparada, N. (Principal Investigator); Dossantos, A. P.; Novo, E. M. L. D.; Duarte, V.
1981-01-01
The use of LANDSAT data to evaluate pasture quality in the Amazon region is demonstrated. Pasture degradation in deforested areas of a traditional tropical forest cattle-raising region was estimated. Automatic analysis using interactive multispectral analysis (IMAGE-100) shows that 24% of the deforested areas were occupied by natural vegetation regrowth, 24% by exposed soil, 15% by degraded pastures, and 46% was suitable grazing land.
NASA Astrophysics Data System (ADS)
Xie, W.-J.; Zhang, L.; Chen, H.-P.; Zhou, J.; Mao, W.-J.
2018-04-01
The purpose of carrying out national geographic conditions monitoring is to obtain information of surface changes caused by human social and economic activities, so that the geographic information can be used to offer better services for the government, enterprise and public. Land cover data contains detailed geographic conditions information, thus has been listed as one of the important achievements in the national geographic conditions monitoring project. At present, the main issue of the production of the land cover data is about how to improve the classification accuracy. For the land cover data quality inspection and acceptance, classification accuracy is also an important check point. So far, the classification accuracy inspection is mainly based on human-computer interaction or manual inspection in the project, which are time consuming and laborious. By harnessing the automatic high-resolution remote sensing image change detection technology based on the ERDAS IMAGINE platform, this paper carried out the classification accuracy inspection test of land cover data in the project, and presented a corresponding technical route, which includes data pre-processing, change detection, result output and information extraction. The result of the quality inspection test shows the effectiveness of the technical route, which can meet the inspection needs for the two typical errors, that is, missing and incorrect update error, and effectively reduces the work intensity of human-computer interaction inspection for quality inspectors, and also provides a technical reference for the data production and quality control of the land cover data.
NASA Technical Reports Server (NTRS)
Katzberg, S. J.; Kelly, W. L., IV; Rowland, C. W.; Burcher, E. E.
1973-01-01
The facsimile camera is an optical-mechanical scanning device which has become an attractive candidate as an imaging system for planetary landers and rovers. This paper presents electronic techniques which permit the acquisition and reconstruction of high quality images with this device, even under varying lighting conditions. These techniques include a control for low frequency noise and drift, an automatic gain control, a pulse-duration light modulation scheme, and a relative spectral gain control. Taken together, these techniques allow the reconstruction of radiometrically accurate and properly balanced color images from facsimile camera video data. These techniques have been incorporated into a facsimile camera and reproduction system, and experimental results are presented for each technique and for the complete system.
NASA Technical Reports Server (NTRS)
Hindson, W. S.; Hardy, G.
1980-01-01
Several different flight research programs carried out by NASA and the Canadian Government using the Augmentor Wing Jet STOL Research Aircraft to investigate the design, operational, and systems requirements for powered-lift STOL aircraft are summarized. Some of these programs considered handling qualities and certification criteria for this class of aircraft, and addressed pilot control techniques, control system design, and improved cockpit displays for the powered-lift STOL approach configuration. Other programs involved exploiting the potential of STOL aircraft for constrained terminal-area approaches within the context of present or future air traffic control environments. Both manual and automatic flight control investigations are discussed, and an extensive bibliography of the flight programs is included.
Noncontact Capacitive Clearance Control System For Laser Cutting Machines
NASA Astrophysics Data System (ADS)
Topkaya, Ahmet; Schmall, Karl-Heinz; Majoli, Ralf
1989-03-01
For a continuous high quality laser cut, it is necessary among other things to position the focal point of the laser beam correctly. This means that a constant clearance between the cutting head and the workpiece with a tolerance of +/- 0.Imm must he ensured. When cutting corrugated automobile bodysheet for example, a good quality cut can only be achieved with automatic clearance control. In the following, a method of automatic clearance control is described using the assistance of a noncontact capacitive sensor system. The copper nozzle of the laser cutting head acts as the electrode of the clearance sensor. The nozzle electrode and the workpiece build a small variable capacitance depending on the clearance. A change of clearance also changes the capacitance, which in turn influences a high frequency oscillator circuit. This shift in frequency is then converted into an analogue DC signal, which can be used to operate a servo motor control for the positioning of the laser cutting head in a closed loop servo system. Laser cutting heads with clearance sensor nozzles of different shapes, suited fur most applications in the industry, with focal lengths from 2.5" to 5" have been developed. They are capable to cut metal sheet from 0.2 to 12 mm of thickness, using CO2-lasers with output power up to 2.5 kW. For special applications involving difficult workpiece topographies in automobile production applications special "trunk" nozzles have been developed. For 5-axis cutting machines and robots, new laser cutting heads with integrated nozzle sensors in combination with a high dynamic Z-axis motor drive are in a stage of development.
[An automatic system controlled by microcontroller for carotid sinus perfusion].
Yi, X L; Wang, M Y; Fan, Z Z; He, R R
2001-08-01
To establish a new method for controlling automatically the carotid perfusion pressure. A cheap practical automatic perfusion unit based on AT89C2051 micro controller was designed. The unit, LDB-M perfusion pump and the carotid sinus of an animal constituted an automatic perfusion system. This system was able to provide ramp and stepwise updown perfusion pattern and has been used in the research of baroreflex. It can insure the precision and reproducibility of perfusion pressure curve, and improve the technical level in corresponding medical field.
A method of automatic control procedures cardiopulmonary resuscitation
NASA Astrophysics Data System (ADS)
Bureev, A. Sh.; Zhdanov, D. S.; Kiseleva, E. Yu.; Kutsov, M. S.; Trifonov, A. Yu.
2015-11-01
The study is to present the results of works on creation of methods of automatic control procedures of cardiopulmonary resuscitation (CPR). A method of automatic control procedure of CPR by evaluating the acoustic data of the dynamics of blood flow in the bifurcation of carotid arteries and the dynamics of air flow in a trachea according to the current guidelines for CPR is presented. Evaluation of the patient is carried out by analyzing the respiratory noise and blood flow in the interspaces between the chest compressions and artificial pulmonary ventilation. The device operation algorithm of automatic control procedures of CPR and its block diagram has been developed.
Evolutionary game dynamics of controlled and automatic decision-making
NASA Astrophysics Data System (ADS)
Toupo, Danielle F. P.; Strogatz, Steven H.; Cohen, Jonathan D.; Rand, David G.
2015-07-01
We integrate dual-process theories of human cognition with evolutionary game theory to study the evolution of automatic and controlled decision-making processes. We introduce a model in which agents who make decisions using either automatic or controlled processing compete with each other for survival. Agents using automatic processing act quickly and so are more likely to acquire resources, but agents using controlled processing are better planners and so make more effective use of the resources they have. Using the replicator equation, we characterize the conditions under which automatic or controlled agents dominate, when coexistence is possible and when bistability occurs. We then extend the replicator equation to consider feedback between the state of the population and the environment. Under conditions in which having a greater proportion of controlled agents either enriches the environment or enhances the competitive advantage of automatic agents, we find that limit cycles can occur, leading to persistent oscillations in the population dynamics. Critically, however, these limit cycles only emerge when feedback occurs on a sufficiently long time scale. Our results shed light on the connection between evolution and human cognition and suggest necessary conditions for the rise and fall of rationality.
Evolutionary game dynamics of controlled and automatic decision-making.
Toupo, Danielle F P; Strogatz, Steven H; Cohen, Jonathan D; Rand, David G
2015-07-01
We integrate dual-process theories of human cognition with evolutionary game theory to study the evolution of automatic and controlled decision-making processes. We introduce a model in which agents who make decisions using either automatic or controlled processing compete with each other for survival. Agents using automatic processing act quickly and so are more likely to acquire resources, but agents using controlled processing are better planners and so make more effective use of the resources they have. Using the replicator equation, we characterize the conditions under which automatic or controlled agents dominate, when coexistence is possible and when bistability occurs. We then extend the replicator equation to consider feedback between the state of the population and the environment. Under conditions in which having a greater proportion of controlled agents either enriches the environment or enhances the competitive advantage of automatic agents, we find that limit cycles can occur, leading to persistent oscillations in the population dynamics. Critically, however, these limit cycles only emerge when feedback occurs on a sufficiently long time scale. Our results shed light on the connection between evolution and human cognition and suggest necessary conditions for the rise and fall of rationality.
Automatic humidification system to support the assessment of food drying processes
NASA Astrophysics Data System (ADS)
Ortiz Hernández, B. D.; Carreño Olejua, A. R.; Castellanos Olarte, J. M.
2016-07-01
This work shows the main features of an automatic humidification system to provide drying air that match environmental conditions of different climate zones. This conditioned air is then used to assess the drying process of different agro-industrial products at the Automation and Control for Agro-industrial Processes Laboratory of the Pontifical Bolivarian University of Bucaramanga, Colombia. The automatic system allows creating and improving control strategies to supply drying air under specified conditions of temperature and humidity. The development of automatic routines to control and acquire real time data was made possible by the use of robust control systems and suitable instrumentation. The signals are read and directed to a controller memory where they are scaled and transferred to a memory unit. Using the IP address is possible to access data to perform supervision tasks. One important characteristic of this automatic system is the Dynamic Data Exchange Server (DDE) to allow direct communication between the control unit and the computer used to build experimental curves.
Self-assessment procedure using fuzzy sets
NASA Astrophysics Data System (ADS)
Mimi, Fotini
2000-10-01
Self-Assessment processes, initiated by a company itself and carried out by its own people, are considered to be the starting point for a regular strategic or operative planning process to ensure a continuous quality improvement. Their importance has increased by the growing relevance and acceptance of international quality awards such as the Malcolm Baldrige National Quality Award, the European Quality Award and the Deming Prize. Especially award winners use the instrument of a systematic and regular Self-Assessment and not only because they have to verify their quality and business results for at least three years. The Total Quality Model of the European Foundation for Quality Management (EFQM), used for the European Quality Award, is the basis for Self-Assessment in Europe. This paper presents a self-assessment supporting method based on a methodology of fuzzy control systems providing an effective means of converting the linguistic approximation into an automatic control strategy. In particular, the elements of the Quality Model mentioned above are interpreted as linguistic variables. The LR-type of a fuzzy interval is used for their representation. The input data has a qualitative character based on empirical investigation and expert knowledge and therefore the base- variables are ordinal scaled. The aggregation process takes place on the basis of a hierarchical structure. Finally, in order to render the use of the method more practical a software system on PC basis is developed and implemented.
ERIC Educational Resources Information Center
Arendasy, Martin; Sommer, Markus
2007-01-01
This article deals with the investigation of the psychometric quality and constructs validity of algebra word problems generated by means of a schema-based version of the automatic min-max approach. Based on review of the research literature in algebra word problem solving and automatic item generation this new approach is introduced as a…
Individual differences in automatic emotion regulation affect the asymmetry of the LPP component.
Zhang, Jing; Zhou, Renlai
2014-01-01
The main goal of this study was to investigate how automatic emotion regulation altered the hemispheric asymmetry of ERPs elicited by emotion processing. We examined the effect of individual differences in automatic emotion regulation on the late positive potential (LPP) when participants were viewing blocks of positive high arousal, positive low arousal, negative high arousal and negative low arousal pictures from International affect picture system (IAPS). Two participant groups were categorized by the Emotion Regulation-Implicit Association Test which has been used in previous research to identify two groups of participants with automatic emotion control and with automatic emotion express. The main finding was that automatic emotion express group showed a right dominance of the LPP component at posterior electrodes, especially in high arousal conditions. But no right dominance of the LPP component was observed for automatic emotion control group. We also found the group with automatic emotion control showed no differences in the right posterior LPP amplitude between high- and low-arousal emotion conditions, while the participants with automatic emotion express showed larger LPP amplitude in the right posterior in high-arousal conditions compared to low-arousal conditions. This result suggested that AER (Automatic emotion regulation) modulated the hemispheric asymmetry of LPP on posterior electrodes and supported the right hemisphere hypothesis.
Quality controls for gamma cameras and PET cameras: development of a free open-source ImageJ program
NASA Astrophysics Data System (ADS)
Carlier, Thomas; Ferrer, Ludovic; Berruchon, Jean B.; Cuissard, Regis; Martineau, Adeline; Loonis, Pierre; Couturier, Olivier
2005-04-01
Acquisition data and treatments for quality controls of gamma cameras and Positron Emission Tomography (PET) cameras are commonly performed with dedicated program packages, which are running only on manufactured computers and differ from each other, depending on camera company and program versions. The aim of this work was to develop a free open-source program (written in JAVA language) to analyze data for quality control of gamma cameras and PET cameras. The program is based on the free application software ImageJ and can be easily loaded on any computer operating system (OS) and thus on any type of computer in every nuclear medicine department. Based on standard parameters of quality control, this program includes 1) for gamma camera: a rotation center control (extracted from the American Association of Physics in Medicine, AAPM, norms) and two uniformity controls (extracted from the Institute of Physics and Engineering in Medicine, IPEM, and National Electronic Manufacturers Association, NEMA, norms). 2) For PET systems, three quality controls recently defined by the French Medical Physicist Society (SFPM), i.e. spatial resolution and uniformity in a reconstructed slice and scatter fraction, are included. The determination of spatial resolution (thanks to the Point Spread Function, PSF, acquisition) allows to compute the Modulation Transfer Function (MTF) in both modalities of cameras. All the control functions are included in a tool box which is a free ImageJ plugin and could be soon downloaded from Internet. Besides, this program offers the possibility to save on HTML format the uniformity quality control results and a warning can be set to automatically inform users in case of abnormal results. The architecture of the program allows users to easily add any other specific quality control program. Finally, this toolkit is an easy and robust tool to perform quality control on gamma cameras and PET cameras based on standard computation parameters, is free, run on any type of computer and will soon be downloadable from the net (http://rsb.info.nih.gov/ij/plugins or http://nucleartoolkit.free.fr).
47 CFR 87.143 - Transmitter control requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Section 87.143 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO..., the control point for an automatically controlled enroute station is the computer facility which controls the transmitter. Any computer controlled transmitter must be equipped to automatically shut down...
47 CFR 87.143 - Transmitter control requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 87.143 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO..., the control point for an automatically controlled enroute station is the computer facility which controls the transmitter. Any computer controlled transmitter must be equipped to automatically shut down...
47 CFR 87.143 - Transmitter control requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Section 87.143 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO..., the control point for an automatically controlled enroute station is the computer facility which controls the transmitter. Any computer controlled transmitter must be equipped to automatically shut down...
47 CFR 87.143 - Transmitter control requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Section 87.143 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO..., the control point for an automatically controlled enroute station is the computer facility which controls the transmitter. Any computer controlled transmitter must be equipped to automatically shut down...
47 CFR 87.143 - Transmitter control requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Section 87.143 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO..., the control point for an automatically controlled enroute station is the computer facility which controls the transmitter. Any computer controlled transmitter must be equipped to automatically shut down...
Quantum optimal control with automatic differentiation using graphics processors
NASA Astrophysics Data System (ADS)
Leung, Nelson; Abdelhafez, Mohamed; Chakram, Srivatsan; Naik, Ravi; Groszkowski, Peter; Koch, Jens; Schuster, David
We implement quantum optimal control based on automatic differentiation and harness the acceleration afforded by graphics processing units (GPUs). Automatic differentiation allows us to specify advanced optimization criteria and incorporate them into the optimization process with ease. We will describe efficient techniques to optimally control weakly anharmonic systems that are commonly encountered in circuit QED, including coupled superconducting transmon qubits and multi-cavity circuit QED systems. These systems allow for a rich variety of control schemes that quantum optimal control is well suited to explore.
Effects of developer depletion on image quality of Kodak Insight and Ektaspeed Plus films.
Casanova, M S; Casanova, M L S; Haiter-Neto, F
2004-03-01
To evaluate the effect of processing solution depletion on the image quality of F-speed dental X-ray film (Insight), compared with Ektaspeed Plus. The films were exposed with a phantom and developed in manual and automatic conditions, in fresh and progressively depleted solutions. The comparison was based on densitometric analysis and subjective appraisal. The processing solution depletion presented a different behaviour depending on whether manual or automatic technique was used. The films were distinctly affected by depleted processing solutions. The developer depletion was faster in automatic than manual conditions. Insight film was more resistant than Ektaspeed Plus to the effects of processing solution depletion. In the present study there was agreement between the objective and subjective appraisals.
Threshold automatic selection hybrid phase unwrapping algorithm for digital holographic microscopy
NASA Astrophysics Data System (ADS)
Zhou, Meiling; Min, Junwei; Yao, Baoli; Yu, Xianghua; Lei, Ming; Yan, Shaohui; Yang, Yanlong; Dan, Dan
2015-01-01
Conventional quality-guided (QG) phase unwrapping algorithm is hard to be applied to digital holographic microscopy because of the long execution time. In this paper, we present a threshold automatic selection hybrid phase unwrapping algorithm that combines the existing QG algorithm and the flood-filled (FF) algorithm to solve this problem. The original wrapped phase map is divided into high- and low-quality sub-maps by selecting a threshold automatically, and then the FF and QG unwrapping algorithms are used in each level to unwrap the phase, respectively. The feasibility of the proposed method is proved by experimental results, and the execution speed is shown to be much faster than that of the original QG unwrapping algorithm.
The transition to increased automaticity during finger sequence learning in adult males who stutter.
Smits-Bandstra, Sarah; De Nil, Luc; Rochon, Elizabeth
2006-01-01
The present study compared the automaticity levels of persons who stutter (PWS) and persons who do not stutter (PNS) on a practiced finger sequencing task under dual task conditions. Automaticity was defined as the amount of attention required for task performance. Twelve PWS and 12 control subjects practiced finger tapping sequences under single and then dual task conditions. Control subjects performed the sequencing task significantly faster and less variably under single versus dual task conditions while PWS' performance was consistently slow and variable (comparable to the dual task performance of control subjects) under both conditions. Control subjects were significantly more accurate on a colour recognition distracter task than PWS under dual task conditions. These results suggested that control subjects transitioned to quick, accurate and increasingly automatic performance on the sequencing task after practice, while PWS did not. Because most stuttering treatment programs for adults include practice and automatization of new motor speech skills, findings of this finger sequencing study and future studies of speech sequence learning may have important implications for how to maximize stuttering treatment effectiveness. As a result of this activity, the participant will be able to: (1) Define automaticity and explain the importance of dual task paradigms to investigate automaticity; (2) Relate the proposed relationship between motor learning and automaticity as stated by the authors; (3) Summarize the reviewed literature concerning the performance of PWS on dual tasks; and (4) Explain why the ability to transition to automaticity during motor learning may have important clinical implications for stuttering treatment effectiveness.
Indicators for the automated analysis of drug prescribing quality.
Coste, J; Séné, B; Milstein, C; Bouée, S; Venot, A
1998-01-01
Irrational and inconsistent drug prescription has considerable impact on morbidity, mortality, health service utilization, and community burden. However, few studies have addressed the methodology of processing the information contained in these drug orders used to study the quality of drug prescriptions and prescriber behavior. We present a comprehensive set of quantitative indicators for the quality of drug prescriptions which can be derived from a drug order. These indicators were constructed using explicit a priori criteria which were previously validated on the basis of scientific data. Automatic computation is straightforward, using a relational database system, such that large sets of prescriptions can be processed with minimal human effort. We illustrate the feasibility and value of this approach by using a large set of 23,000 prescriptions for several diseases, selected from a nationally representative prescriptions database. Our study may result in direct and wide applications in the epidemiology of medical practice and in quality control procedures.
Gerth, Sabrina; Klassert, Annegret; Dolk, Thomas; Fliesser, Michael; Fischer, Martin H; Nottbusch, Guido; Festman, Julia
2016-01-01
Due to their multifunctionality, tablets offer tremendous advantages for research on handwriting dynamics or for interactive use of learning apps in schools. Further, the widespread use of tablet computers has had a great impact on handwriting in the current generation. But, is it advisable to teach how to write and to assess handwriting in pre- and primary schoolchildren on tablets rather than on paper? Since handwriting is not automatized before the age of 10 years, children's handwriting movements require graphomotor and visual feedback as well as permanent control of movement execution during handwriting. Modifications in writing conditions, for instance the smoother writing surface of a tablet, might influence handwriting performance in general and in particular those of non-automatized beginning writers. In order to investigate how handwriting performance is affected by a difference in friction of the writing surface, we recruited three groups with varying levels of handwriting automaticity: 25 preschoolers, 27 second graders, and 25 adults. We administered three tasks measuring graphomotor abilities, visuomotor abilities, and handwriting performance (only second graders and adults). We evaluated two aspects of handwriting performance: the handwriting quality with a visual score and the handwriting dynamics using online handwriting measures [e.g., writing duration, writing velocity, strokes and number of inversions in velocity (NIV)]. In particular, NIVs which describe the number of velocity peaks during handwriting are directly related to the level of handwriting automaticity. In general, we found differences between writing on paper compared to the tablet. These differences were partly task-dependent. The comparison between tablet and paper revealed a faster writing velocity for all groups and all tasks on the tablet which indicates that all participants-even the experienced writers-were influenced by the lower friction of the tablet surface. Our results for the group-comparison show advancing levels in handwriting automaticity from preschoolers to second graders to adults, which confirms that our method depicts handwriting performance in groups with varying degrees of handwriting automaticity. We conclude that the smoother tablet surface requires additional control of handwriting movements and therefore might present an additional challenge for learners of handwriting.
Gerth, Sabrina; Klassert, Annegret; Dolk, Thomas; Fliesser, Michael; Fischer, Martin H.; Nottbusch, Guido; Festman, Julia
2016-01-01
Due to their multifunctionality, tablets offer tremendous advantages for research on handwriting dynamics or for interactive use of learning apps in schools. Further, the widespread use of tablet computers has had a great impact on handwriting in the current generation. But, is it advisable to teach how to write and to assess handwriting in pre- and primary schoolchildren on tablets rather than on paper? Since handwriting is not automatized before the age of 10 years, children's handwriting movements require graphomotor and visual feedback as well as permanent control of movement execution during handwriting. Modifications in writing conditions, for instance the smoother writing surface of a tablet, might influence handwriting performance in general and in particular those of non-automatized beginning writers. In order to investigate how handwriting performance is affected by a difference in friction of the writing surface, we recruited three groups with varying levels of handwriting automaticity: 25 preschoolers, 27 second graders, and 25 adults. We administered three tasks measuring graphomotor abilities, visuomotor abilities, and handwriting performance (only second graders and adults). We evaluated two aspects of handwriting performance: the handwriting quality with a visual score and the handwriting dynamics using online handwriting measures [e.g., writing duration, writing velocity, strokes and number of inversions in velocity (NIV)]. In particular, NIVs which describe the number of velocity peaks during handwriting are directly related to the level of handwriting automaticity. In general, we found differences between writing on paper compared to the tablet. These differences were partly task-dependent. The comparison between tablet and paper revealed a faster writing velocity for all groups and all tasks on the tablet which indicates that all participants—even the experienced writers—were influenced by the lower friction of the tablet surface. Our results for the group-comparison show advancing levels in handwriting automaticity from preschoolers to second graders to adults, which confirms that our method depicts handwriting performance in groups with varying degrees of handwriting automaticity. We conclude that the smoother tablet surface requires additional control of handwriting movements and therefore might present an additional challenge for learners of handwriting. PMID:27672372
Real-time robot deliberation by compilation and monitoring of anytime algorithms
NASA Technical Reports Server (NTRS)
Zilberstein, Shlomo
1994-01-01
Anytime algorithms are algorithms whose quality of results improves gradually as computation time increases. Certainty, accuracy, and specificity are metrics useful in anytime algorighm construction. It is widely accepted that a successful robotic system must trade off between decision quality and the computational resources used to produce it. Anytime algorithms were designed to offer such a trade off. A model of compilation and monitoring mechanisms needed to build robots that can efficiently control their deliberation time is presented. This approach simplifies the design and implementation of complex intelligent robots, mechanizes the composition and monitoring processes, and provides independent real time robotic systems that automatically adjust resource allocation to yield optimum performance.
49 CFR 236.739 - Device, acknowledging.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.739... locomotive equipped with an automatic train stop or train control device, an automatic brake application can be forestalled, or by means of which, on a locomotive equipped with an automatic cab signal device...
ERIC Educational Resources Information Center
Servant, Mathieu; Cassey, Peter; Woodman, Geoffrey F.; Logan, Gordon D.
2018-01-01
Automaticity allows us to perform tasks in a fast, efficient, and effortless manner after sufficient practice. Theories of automaticity propose that across practice processing transitions from being controlled by working memory to being controlled by long-term memory retrieval. Recent event-related potential (ERP) studies have sought to test this…
Automatic NEPHIS Coding of Descriptive Titles for Permuted Index Generation.
ERIC Educational Resources Information Center
Craven, Timothy C.
1982-01-01
Describes a system for the automatic coding of most descriptive titles which generates Nested Phrase Indexing System (NEPHIS) input strings of sufficient quality for permuted index production. A series of examples and an 11-item reference list accompany the text. (JL)
A clinical research analytics toolkit for cohort study.
Yu, Yiqin; Zhu, Yu; Sun, Xingzhi; Tao, Ying; Zhang, Shuo; Xu, Linhao; Pan, Yue
2012-01-01
This paper presents a clinical informatics toolkit that can assist physicians to conduct cohort studies effectively and efficiently. The toolkit has three key features: 1) support of procedures defined in epidemiology, 2) recommendation of statistical methods in data analysis, and 3) automatic generation of research reports. On one hand, our system can help physicians control research quality by leveraging the integrated knowledge of epidemiology and medical statistics; on the other hand, it can improve productivity by reducing the complexities for physicians during their cohort studies.
The integrated manual and automatic control of complex flight systems
NASA Technical Reports Server (NTRS)
Schmidt, David K.
1991-01-01
Research dealt with the general area of optimal flight control synthesis for manned flight vehicles. The work was generic; no specific vehicle was the focus of study. However, the class of vehicles generally considered were those for which high authority, multivariable control systems might be considered, for the purpose of stabilization and the achievement of optimal handling characteristics. Within this scope, the topics of study included several optimal control synthesis techniques, control-theoretic modeling of the human operator in flight control tasks, and the development of possible handling qualities metrics and/or measures of merit. Basic contributions were made in all these topics, including human operator (pilot) models for multi-loop tasks, optimal output feedback flight control synthesis techniques; experimental validations of the methods developed, and fundamental modeling studies of the air-to-air tracking and flared landing tasks.
Run-to-Run Optimization Control Within Exact Inverse Framework for Scan Tracking.
Yeoh, Ivan L; Reinhall, Per G; Berg, Martin C; Chizeck, Howard J; Seibel, Eric J
2017-09-01
A run-to-run optimization controller uses a reduced set of measurement parameters, in comparison to more general feedback controllers, to converge to the best control point for a repetitive process. A new run-to-run optimization controller is presented for the scanning fiber device used for image acquisition and display. This controller utilizes very sparse measurements to estimate a system energy measure and updates the input parameterizations iteratively within a feedforward with exact-inversion framework. Analysis, simulation, and experimental investigations on the scanning fiber device demonstrate improved scan accuracy over previous methods and automatic controller adaptation to changing operating temperature. A specific application example and quantitative error analyses are provided of a scanning fiber endoscope that maintains high image quality continuously across a 20 °C temperature rise without interruption of the 56 Hz video.
Computer vision system: a tool for evaluating the quality of wheat in a grain tank
NASA Astrophysics Data System (ADS)
Minkin, Uryi Igorevish; Panchenko, Aleksei Vladimirovich; Shkanaev, Aleksandr Yurievich; Konovalenko, Ivan Andreevich; Putintsev, Dmitry Nikolaevich; Sadekov, Rinat Nailevish
2018-04-01
The paper describes a technology that allows for automatizing the process of evaluating the grain quality in a grain tank of a combine harvester. Special recognition algorithm analyzes photographic images taken by the camera, and that provides automatic estimates of the total mass fraction of broken grains and the presence of non-grains. The paper also presents the operating details of the tank prototype as well as it defines the accuracy of the algorithms designed.
Detection technology research on the one-way clutch of automatic brake adjuster
NASA Astrophysics Data System (ADS)
Jiang, Wensong; Luo, Zai; Lu, Yi
2013-10-01
In this article, we provide a new testing method to evaluate the acceptable quality of the one-way clutch of automatic brake adjuster. To analysis the suitable adjusting brake moment which keeps the automatic brake adjuster out of failure, we build a mechanical model of one-way clutch according to the structure and the working principle of one-way clutch. The ranges of adjusting brake moment both clockwise and anti-clockwise can be calculated through the mechanical model of one-way clutch. Its critical moment, as well, are picked up as the ideal values of adjusting brake moment to evaluate the acceptable quality of one-way clutch of automatic brake adjuster. we calculate the ideal values of critical moment depending on the different structure of one-way clutch based on its mechanical model before the adjusting brake moment test begin. In addition, an experimental apparatus, which the uncertainty of measurement is ±0.1Nm, is specially designed to test the adjusting brake moment both clockwise and anti-clockwise. Than we can judge the acceptable quality of one-way clutch of automatic brake adjuster by comparing the test results and the ideal values instead of the EXP. In fact, the evaluation standard of adjusting brake moment applied on the project are still using the EXP provided by manufacturer currently in China, but it would be unavailable when the material of one-way clutch changed. Five kinds of automatic brake adjusters are used in the verification experiment to verify the accuracy of the test method. The experimental results show that the experimental values of adjusting brake moment both clockwise and anti-clockwise are within the ranges of theoretical results. The testing method provided by this article vividly meet the requirements of manufacturer's standard.
Distributed automatic control of technological processes in conditions of weightlessness
NASA Technical Reports Server (NTRS)
Kukhtenko, A. I.; Merkulov, V. I.; Samoylenko, Y. I.; Ladikov-Royev, Y. P.
1986-01-01
Some problems associated with the automatic control of liquid metal and plasma systems under conditions of weightlessness are examined, with particular reference to the problem of stability of liquid equilibrium configurations. The theoretical fundamentals of automatic control of processes in electrically conducting continuous media are outlined, and means of using electromagnetic fields for simulating technological processes in a space environment are discussed.
Steenstrup, B; Giralte, F; Bakker, E; Grise, P
2014-12-01
The aim of this work was to evaluate the effect of postural awareness by using the Wii Fit Plus© on the quality of the baseline (automatic) activity of the pelvic floor muscles (PFM) measured by intravaginal surface electromyography (sEMG). Four healthy continent female subjects, all able to perform a voluntary contraction, undertook 2 sets of 3 various exercises offered by the software Wii Fit Plus© using the Wii balance board© (WBB): one set without any visual control and the second set with postural control and sEMG visual feedback. Simultaneously, we recorded the sEMG activity of the PFM. Mean baseline activity of PFM in standing position at start was 2.87 mV, at submaximal voluntary contraction the sEMG activity raised at a mean of 14.43 mV (7.87-21.89). In the first set of exercises on the WBB without any visual feedback, the automatic activity of the PFM increased from 2.87 mV to 8.75 mV (7.96-9.59). In the second set, with visual postural and sEMG control, mean baseline sEMG activity even raised at 11.39 mV (10.17-11.58). Among women able of a voluntary contraction of PFM, visualisation of posture with the help of the WBB and of sEMG activity of the PFM during static and dynamic Wii Fit Plus© activities, may improve the automatic activation of the PFMs. 4. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Granzer, T.; Reegen, P.; Strassmeier, K. G.
2001-12-01
We present a summary of five years of continuous operation of the University of Vienna twin Automatic Photoelectric Telescopes (APTs) -- Wolfgang and Amadeus. These two telescopes are part of the Fairborn Observatory facility located in the Sonoran desert close to Washington Camp in southern Arizona. The detection and distinction procedure between weather-induced data-quality loss and systematic data-quality loss turned out to be a crucial task. Therefore, special emphasis is laid on the data quality monitoring tools developed throughout the years. Furthermore, we summarize the scientific highlights from the first five years of operation
46 CFR 58.25-80 - Automatic pilots and ancillary steering gear.
Code of Federal Regulations, 2010 CFR
2010-10-01
... AND AUXILIARY MACHINERY AND RELATED SYSTEMS Steering Gear § 58.25-80 Automatic pilots and ancillary steering gear. (a) Automatic pilots and ancillary steering gear, and steering-gear control systems, must be arranged to allow immediate resumption of manual operation of the steering-gear control system required in...
46 CFR 58.25-80 - Automatic pilots and ancillary steering gear.
Code of Federal Regulations, 2011 CFR
2011-10-01
... AND AUXILIARY MACHINERY AND RELATED SYSTEMS Steering Gear § 58.25-80 Automatic pilots and ancillary steering gear. (a) Automatic pilots and ancillary steering gear, and steering-gear control systems, must be arranged to allow immediate resumption of manual operation of the steering-gear control system required in...
Event-Related Potential Evidence that Automatic Recollection Can Be Voluntarily Avoided
ERIC Educational Resources Information Center
Bergstrom, Zara M.; de Fockert, Jan; Richardson-Klavehn, Alan
2009-01-01
Voluntary control processes can be recruited to facilitate recollection in situations where a retrieval cue fails to automatically bring to mind a desired episodic memory. We investigated whether voluntary control processes can also stop recollection of unwanted memories that would otherwise have been automatically recollected. Participants were…
SIMULATING LOCAL DENSE AREAS USING PMMA TO ASSESS AUTOMATIC EXPOSURE CONTROL IN DIGITAL MAMMOGRAPHY.
Bouwman, R W; Binst, J; Dance, D R; Young, K C; Broeders, M J M; den Heeten, G J; Veldkamp, W J H; Bosmans, H; van Engen, R E
2016-06-01
Current digital mammography (DM) X-ray systems are equipped with advanced automatic exposure control (AEC) systems, which determine the exposure factors depending on breast composition. In the supplement of the European guidelines for quality assurance in breast cancer screening and diagnosis, a phantom-based test is included to evaluate the AEC response to local dense areas in terms of signal-to-noise ratio (SNR). This study evaluates the proposed test in terms of SNR and dose for four DM systems. The glandular fraction represented by the local dense area was assessed by analytic calculations. It was found that the proposed test simulates adipose to fully glandular breast compositions in attenuation. The doses associated with the phantoms were found to match well with the patient dose distribution. In conclusion, after some small adaptations, the test is valuable for the assessment of the AEC performance in terms of both SNR and dose. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Automated Translation of Safety Critical Application Software Specifications into PLC Ladder Logic
NASA Technical Reports Server (NTRS)
Leucht, Kurt W.; Semmel, Glenn S.
2008-01-01
The numerous benefits of automatic application code generation are widely accepted within the software engineering community. A few of these benefits include raising the abstraction level of application programming, shorter product development time, lower maintenance costs, and increased code quality and consistency. Surprisingly, code generation concepts have not yet found wide acceptance and use in the field of programmable logic controller (PLC) software development. Software engineers at the NASA Kennedy Space Center (KSC) recognized the need for PLC code generation while developing their new ground checkout and launch processing system. They developed a process and a prototype software tool that automatically translates a high-level representation or specification of safety critical application software into ladder logic that executes on a PLC. This process and tool are expected to increase the reliability of the PLC code over that which is written manually, and may even lower life-cycle costs and shorten the development schedule of the new control system at KSC. This paper examines the problem domain and discusses the process and software tool that were prototyped by the KSC software engineers.
Improving integrity of on-line grammage measurement with traceable basic calibration.
Kangasrääsiö, Juha
2010-07-01
The automatic control of grammage (basis weight) in paper and board production is based upon on-line grammage measurement. Furthermore, the automatic control of other quality variables such as moisture, ash content and coat weight, may rely on the grammage measurement. The integrity of Kr-85 based on-line grammage measurement systems was studied, by performing basic calibrations with traceably calibrated plastic reference standards. The calibrations were performed according to the EN ISO/IEC 17025 standard, which is a requirement for calibration laboratories. The observed relative measurement errors were 3.3% in the first time calibrations at the 95% confidence level. With the traceable basic calibration method, however, these errors can be reduced to under 0.5%, thus improving the integrity of on-line grammage measurements. Also a standardised algorithm, based on the experience from the performed calibrations, is proposed to ease the adjustment of the different grammage measurement systems. The calibration technique can basically be applied to all beta-radiation based grammage measurements. 2010 ISA. Published by Elsevier Ltd. All rights reserved.
A high-quality high-fidelity visualization of the September 11 attack on the World Trade Center.
Rosen, Paul; Popescu, Voicu; Hoffmann, Christoph; Irfanoglu, Ayhan
2008-01-01
In this application paper, we describe the efforts of a multidisciplinary team towards producing a visualization of the September 11 Attack on the North Tower of New York's World Trade Center. The visualization was designed to meet two requirements. First, the visualization had to depict the impact with high fidelity, by closely following the laws of physics. Second, the visualization had to be eloquent to a nonexpert user. This was achieved by first designing and computing a finite-element analysis (FEA) simulation of the impact between the aircraft and the top 20 stories of the building, and then by visualizing the FEA results with a state-of-the-art commercial animation system. The visualization was enabled by an automatic translator that converts the simulation data into an animation system 3D scene. We built upon a previously developed translator. The translator was substantially extended to enable and control visualization of fire and of disintegrating elements, to better scale with the number of nodes and number of states, to handle beam elements with complex profiles, and to handle smoothed particle hydrodynamics liquid representation. The resulting translator is a powerful automatic and scalable tool for high-quality visualization of FEA results.
Flight Dynamics Aspects of a Large Civil Tiltrotor Simulation Using Translational Rate Command
NASA Technical Reports Server (NTRS)
Lawrence, Ben; Malpica, Carlos A.; Theodore, Colin R.; Decker, William A.; Lindsey, James E.
2011-01-01
An in-depth analysis of a Large Civil Tiltrotor simulation with a Translational Rate Command control law that uses automatic nacelle deflections for longitudinal velocity control and lateral cyclic for lateral velocity control is presented. Results from piloted real-time simulation experiments and offline time and frequency domain analyses are used to investigate the fundamental flight dynamic and control mechanisms of the control law. The baseline Translational Rate Command conferred handling qualities improvements over an attitude command attitude hold control law but in some scenarios there was a tendency to enter PIO. Nacelle actuator rate limiting strongly influenced the PIO tendency and reducing the rate limits degraded the handling qualities further. Counterintuitively, increasing rate limits also led to a worsening of the handling qualities ratings. This led to the identification of a nacelle rate to rotor longitudinal flapping coupling effect that induced undesired pitching motions proportional to the allowable amount of nacelle rate. A modification that applied a counteracting amount of longitudinal cyclic proportional to the nacelle rate significantly improved the handling qualities. The lateral axis of the Translational Rate Command conferred Level 1 handling qualities in a Lateral Reposition maneuver. Analysis of the influence of the modeling fidelity on the lateral flapping angles is presented. It is showed that the linear modeling approximation is likely to have under-predicted the side-force and therefore under-predicted the lateral flapping at velocities above 15 ft/s. However, at lower velocities, and therefore more weakly influenced by the side force modeling, the accelerations that the control law commands also significantly influenced the peak levels of lateral flapping achieved.
Improved statistical method for temperature and salinity quality control
NASA Astrophysics Data System (ADS)
Gourrion, Jérôme; Szekely, Tanguy
2017-04-01
Climate research and Ocean monitoring benefit from the continuous development of global in-situ hydrographic networks in the last decades. Apart from the increasing volume of observations available on a large range of temporal and spatial scales, a critical aspect concerns the ability to constantly improve the quality of the datasets. In the context of the Coriolis Dataset for ReAnalysis (CORA) version 4.2, a new quality control method based on a local comparison to historical extreme values ever observed is developed, implemented and validated. Temperature, salinity and potential density validity intervals are directly estimated from minimum and maximum values from an historical reference dataset, rather than from traditional mean and standard deviation estimates. Such an approach avoids strong statistical assumptions on the data distributions such as unimodality, absence of skewness and spatially homogeneous kurtosis. As a new feature, it also allows addressing simultaneously the two main objectives of an automatic quality control strategy, i.e. maximizing the number of good detections while minimizing the number of false alarms. The reference dataset is presently built from the fusion of 1) all ARGO profiles up to late 2015, 2) 3 historical CTD datasets and 3) the Sea Mammals CTD profiles from the MEOP database. All datasets are extensively and manually quality controlled. In this communication, the latest method validation results are also presented. The method has already been implemented in the latest version of the delayed-time CMEMS in-situ dataset and will be deployed soon in the equivalent near-real time products.
Automatic motor activation in the executive control of action
McBride, Jennifer; Boy, Frédéric; Husain, Masud; Sumner, Petroc
2012-01-01
Although executive control and automatic behavior have often been considered separate and distinct processes, there is strong emerging and convergent evidence that they may in fact be intricately interlinked. In this review, we draw together evidence showing that visual stimuli cause automatic and unconscious motor activation, and how this in turn has implications for executive control. We discuss object affordances, alien limb syndrome, the visual grasp reflex, subliminal priming, and subliminal triggering of attentional orienting. Consideration of these findings suggests automatic motor activation might form an intrinsic part of all behavior, rather than being categorically different from voluntary actions. PMID:22536177
Realization of the ergonomics design and automatic control of the fundus cameras
NASA Astrophysics Data System (ADS)
Zeng, Chi-liang; Xiao, Ze-xin; Deng, Shi-chao; Yu, Xin-ye
2012-12-01
The principles of ergonomics design in fundus cameras should be extending the agreeableness by automatic control. Firstly, a 3D positional numerical control system is designed for positioning the eye pupils of the patients who are doing fundus examinations. This system consists of a electronically controlled chin bracket for moving up and down, a lateral movement of binocular with the detector and the automatic refocusing of the edges of the eye pupils. Secondly, an auto-focusing device for the object plane of patient's fundus is designed, which collects the patient's fundus images automatically whether their eyes is ametropic or not. Finally, a moving visual target is developed for expanding the fields of the fundus images.
Automatic, semi-automatic and manual validation of urban drainage data.
Branisavljević, N; Prodanović, D; Pavlović, D
2010-01-01
Advances in sensor technology and the possibility of automated long distance data transmission have made continuous measurements the preferable way of monitoring urban drainage processes. Usually, the collected data have to be processed by an expert in order to detect and mark the wrong data, remove them and replace them with interpolated data. In general, the first step in detecting the wrong, anomaly data is called the data quality assessment or data validation. Data validation consists of three parts: data preparation, validation scores generation and scores interpretation. This paper will present the overall framework for the data quality improvement system, suitable for automatic, semi-automatic or manual operation. The first two steps of the validation process are explained in more detail, using several validation methods on the same set of real-case data from the Belgrade sewer system. The final part of the validation process, which is the scores interpretation, needs to be further investigated on the developed system.
49 CFR 236.504 - Operation interconnected with automatic block-signal system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Operation interconnected with automatic block... Operation interconnected with automatic block-signal system. (a) A continuous inductive automatic train stop or train control system shall operate in connection with an automatic block signal system and shall...
NASA Astrophysics Data System (ADS)
Lora-Millán, Julio S.; Taguas, Encarnacion V.; Gomez, Jose A.; Perez, Rafael
2014-05-01
Long term soil erosion studies imply substantial efforts, particularly when there is the need to maintain continuous measurements. There are high costs associated to maintenance of field equipment keeping and quality control of data collection. Energy supply and/or electronic failures, vandalism and burglary are common causes of gaps in datasets, reducing their reach in many cases. In this work, a system of three video-cameras, a recorder and a transmission modem (3G technology) has been set up in a gauging station where rainfall, runoff flow and sediment concentration are monitored. The gauging station is located in the outlet of an olive orchard catchment of 6.4 ha. Rainfall is measured with one automatic raingauge that records intensity at one minute intervals. The discharge is measured by a flume of critical flow depth, where the water is recorded by an ultrasonic sensor. When the water level rises to a predetermined level, the automatic sampler turns on and fills a bottle at different intervals according to a program depending on the antecedent precipitation. A data logger controls the instruments' functions and records the data. The purpose of the video-camera system is to improve the quality of the dataset by i) the visual analysis of the measurement conditions of flow into the flume; ii) the optimisation of the sampling programs. The cameras are positioned to record the flow at the approximation and the gorge of the flume. In order to contrast the values of ultrasonic sensor, there is a third camera recording the flow level close to a measure tape. This system is activated when the ultrasonic sensor detects a height threshold, equivalent to an electric intensity level. Thus, only when there is enough flow, video-cameras record the event. This simplifies post-processing and reduces the cost of download of recordings. The preliminary contrast analysis will be presented as well as the main improvements in the sample program.
Metnitz, P G; Laback, P; Popow, C; Laback, O; Lenz, K; Hiesmayr, M
1995-01-01
Patient Data Management Systems (PDMS) for ICUs collect, present and store clinical data. Various intentions make analysis of those digitally stored data desirable, such as quality control or scientific purposes. The aim of the Intensive Care Data Evaluation project (ICDEV), was to provide a database tool for the analysis of data recorded at various ICUs at the University Clinics of Vienna. General Hospital of Vienna, with two different PDMSs used: CareVue 9000 (Hewlett Packard, Andover, USA) at two ICUs (one medical ICU and one neonatal ICU) and PICIS Chart+ (PICIS, Paris, France) at one Cardiothoracic ICU. CONCEPT AND METHODS: Clinically oriented analysis of the data collected in a PDMS at an ICU was the beginning of the development. After defining the database structure we established a client-server based database system under Microsoft Windows NI and developed a user friendly data quering application using Microsoft Visual C++ and Visual Basic; ICDEV was successfully installed at three different ICUs, adjustment to the different PDMS configurations were done within a few days. The database structure developed by us enables a powerful query concept representing an 'EXPERT QUESTION COMPILER' which may help to answer almost any clinical questions. Several program modules facilitate queries at the patient, group and unit level. Results from ICDEV-queries are automatically transferred to Microsoft Excel for display (in form of configurable tables and graphs) and further processing. The ICDEV concept is configurable for adjustment to different intensive care information systems and can be used to support computerized quality control. However, as long as there exists no sufficient artifact recognition or data validation software for automatically recorded patient data, the reliability of these data and their usage for computer assisted quality control remain unclear and should be further studied.
Bruland, Philipp; Doods, Justin; Storck, Michael; Dugas, Martin
2017-01-01
Data dictionaries provide structural meta-information about data definitions in health information technology (HIT) systems. In this regard, reusing healthcare data for secondary purposes offers several advantages (e.g. reduce documentation times or increased data quality). Prerequisites for data reuse are its quality, availability and identical meaning of data. In diverse projects, research data warehouses serve as core components between heterogeneous clinical databases and various research applications. Given the complexity (high number of data elements) and dynamics (regular updates) of electronic health record (EHR) data structures, we propose a clinical metadata warehouse (CMDW) based on a metadata registry standard. Metadata of two large hospitals were automatically inserted into two CMDWs containing 16,230 forms and 310,519 data elements. Automatic updates of metadata are possible as well as semantic annotations. A CMDW allows metadata discovery, data quality assessment and similarity analyses. Common data models for distributed research networks can be established based on similarity analyses.
Kim, Heejun; Bian, Jiantao; Mostafa, Javed; Jonnalagadda, Siddhartha; Del Fiol, Guilherme
2016-01-01
Motivation: Clinicians need up-to-date evidence from high quality clinical trials to support clinical decisions. However, applying evidence from the primary literature requires significant effort. Objective: To examine the feasibility of automatically extracting key clinical trial information from ClinicalTrials.gov. Methods: We assessed the coverage of ClinicalTrials.gov for high quality clinical studies that are indexed in PubMed. Using 140 random ClinicalTrials.gov records, we developed and tested rules for the automatic extraction of key information. Results: The rate of high quality clinical trial registration in ClinicalTrials.gov increased from 0.2% in 2005 to 17% in 2015. Trials reporting results increased from 3% in 2005 to 19% in 2015. The accuracy of the automatic extraction algorithm for 10 trial attributes was 90% on average. Future research is needed to improve the algorithm accuracy and to design information displays to optimally present trial information to clinicians. PMID:28269867
AutoLock: a semiautomated system for radiotherapy treatment plan quality control
Lowe, Matthew; Hardy, Mark J.; Boylan, Christopher J.; Whitehurst, Philip; Rowbottom, Carl G.
2015-01-01
A semiautomated system for radiotherapy treatment plan quality control (QC), named AutoLock, is presented. AutoLock is designed to augment treatment plan QC by automatically checking aspects of treatment plans that are well suited to computational evaluation, whilst summarizing more subjective aspects in the form of a checklist. The treatment plan must pass all automated checks and all checklist items must be acknowledged by the planner as correct before the plan is finalized. Thus AutoLock uniquely integrates automated treatment plan QC, an electronic checklist, and plan finalization. In addition to reducing the potential for the propagation of errors, the integration of AutoLock into the plan finalization workflow has improved efficiency at our center. Detailed audit data are presented, demonstrating that the treatment plan QC rejection rate fell by around a third following the clinical introduction of AutoLock. PACS number: 87.55.Qr PMID:26103498
AutoLock: a semiautomated system for radiotherapy treatment plan quality control.
Dewhurst, Joseph M; Lowe, Matthew; Hardy, Mark J; Boylan, Christopher J; Whitehurst, Philip; Rowbottom, Carl G
2015-05-08
A semiautomated system for radiotherapy treatment plan quality control (QC), named AutoLock, is presented. AutoLock is designed to augment treatment plan QC by automatically checking aspects of treatment plans that are well suited to computational evaluation, whilst summarizing more subjective aspects in the form of a checklist. The treatment plan must pass all automated checks and all checklist items must be acknowledged by the planner as correct before the plan is finalized. Thus AutoLock uniquely integrates automated treatment plan QC, an electronic checklist, and plan finalization. In addition to reducing the potential for the propagation of errors, the integration of AutoLock into the plan finalization workflow has improved efficiency at our center. Detailed audit data are presented, demonstrating that the treatment plan QC rejection rate fell by around a third following the clinical introduction of AutoLock.
Fully automatic multi-atlas segmentation of CTA for partial volume correction in cardiac SPECT/CT
NASA Astrophysics Data System (ADS)
Liu, Qingyi; Mohy-ud-Din, Hassan; Boutagy, Nabil E.; Jiang, Mingyan; Ren, Silin; Stendahl, John C.; Sinusas, Albert J.; Liu, Chi
2017-05-01
Anatomical-based partial volume correction (PVC) has been shown to improve image quality and quantitative accuracy in cardiac SPECT/CT. However, this method requires manual segmentation of various organs from contrast-enhanced computed tomography angiography (CTA) data. In order to achieve fully automatic CTA segmentation for clinical translation, we investigated the most common multi-atlas segmentation methods. We also modified the multi-atlas segmentation method by introducing a novel label fusion algorithm for multiple organ segmentation to eliminate overlap and gap voxels. To evaluate our proposed automatic segmentation, eight canine 99mTc-labeled red blood cell SPECT/CT datasets that incorporated PVC were analyzed, using the leave-one-out approach. The Dice similarity coefficient of each organ was computed. Compared to the conventional label fusion method, our proposed label fusion method effectively eliminated gaps and overlaps and improved the CTA segmentation accuracy. The anatomical-based PVC of cardiac SPECT images with automatic multi-atlas segmentation provided consistent image quality and quantitative estimation of intramyocardial blood volume, as compared to those derived using manual segmentation. In conclusion, our proposed automatic multi-atlas segmentation method of CTAs is feasible, practical, and facilitates anatomical-based PVC of cardiac SPECT/CT images.
WE-G-BRF-09: Force- and Image-Adaptive Strategies for Robotised Placement of 4D Ultrasound Probes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuhlemann, I; Graduate School for Computing in Life Science, University of Luebeck, Luebeck; Bruder, R
2014-06-15
Purpose: To allow continuous acquisition of high quality 4D ultrasound images for non-invasive live tracking of tumours for IGRT, image- and force-adaptive strategies for robotised placement of 4D ultrasound probes are developed and evaluated. Methods: The developed robotised ultrasound system is based on a 6-axes industrial robot (adept Viper s850) carrying a 4D ultrasound transducer with a mounted force-torque sensor. The force-adaptive placement strategies include probe position control using artificial potential fields and contact pressure regulation by a PD controller strategy. The basis for live target tracking is a continuous minimum contact pressure to ensure good image quality and highmore » patient comfort. This contact pressure can be significantly disturbed by respiratory movements and has to be compensated. All measurements were performed on human subjects under realistic conditions. When performing cardiac ultrasound, rib- and lung shadows are a common source of interference and can disrupt the tracking. To ensure continuous tracking, these artefacts had to be detected to automatically realign the probe. The detection is realised by multiple algorithms based on entropy calculations as well as a determination of the image quality. Results: Through active contact pressure regulation it was possible to reduce the variance of the contact pressure by 89.79% despite respiratory motion of the chest. The results regarding the image processing clearly demonstrate the feasibility to detect image artefacts like rib shadows in real-time. Conclusion: In all cases, it was possible to stabilise the image quality by active contact pressure control and automatically detected image artefacts. This fact enables the possibility to compensate for such interferences by realigning the probe and thus continuously optimising the ultrasound images. This is a huge step towards fully automated transducer positioning and opens the possibility for stable target tracking in ultrasoundguided radiation therapy requiring contact pressure of 5–10 N. This work was supported by the Graduate School for Computing in Medicine and Life Sciences funded by Germany's Excellence Initiative [DFG GSC 235/1].« less
Automatized alignment control of wing mechanization in aerodynamic contour of aircraft
NASA Astrophysics Data System (ADS)
Odnokurtsev, K. A.
2018-05-01
The method of automatized control of accuracy of an aircraft aerodynamic contour when mounting wing mechanization elements is described in the article. A control device in the stand of the wing assembling, equipped with the distance sensors, is suggested to be used. The measurement of control points’ inaccuracies is made automatically in a special computer program. Two kinds of sensor calibration are made in advance in order to increase the accuracy of measurements. As a result, the duration of control and adjustment of mechanization elements is reduced.
Automatic Carbon Dioxide-Methane Gas Sensor Based on the Solubility of Gases in Water
Cadena-Pereda, Raúl O.; Rivera-Muñoz, Eric M.; Herrera-Ruiz, Gilberto; Gomez-Melendez, Domingo J.; Anaya-Rivera, Ely K.
2012-01-01
Biogas methane content is a relevant variable in anaerobic digestion processing where knowledge of process kinetics or an early indicator of digester failure is needed. The contribution of this work is the development of a novel, simple and low cost automatic carbon dioxide-methane gas sensor based on the solubility of gases in water as the precursor of a sensor for biogas quality monitoring. The device described in this work was used for determining the composition of binary mixtures, such as carbon dioxide-methane, in the range of 0–100%. The design and implementation of a digital signal processor and control system into a low-cost Field Programmable Gate Array (FPGA) platform has permitted the successful application of data acquisition, data distribution and digital data processing, making the construction of a standalone carbon dioxide-methane gas sensor possible. PMID:23112626
Automatic carbon dioxide-methane gas sensor based on the solubility of gases in water.
Cadena-Pereda, Raúl O; Rivera-Muñoz, Eric M; Herrera-Ruiz, Gilberto; Gomez-Melendez, Domingo J; Anaya-Rivera, Ely K
2012-01-01
Biogas methane content is a relevant variable in anaerobic digestion processing where knowledge of process kinetics or an early indicator of digester failure is needed. The contribution of this work is the development of a novel, simple and low cost automatic carbon dioxide-methane gas sensor based on the solubility of gases in water as the precursor of a sensor for biogas quality monitoring. The device described in this work was used for determining the composition of binary mixtures, such as carbon dioxide-methane, in the range of 0-100%. The design and implementation of a digital signal processor and control system into a low-cost Field Programmable Gate Array (FPGA) platform has permitted the successful application of data acquisition, data distribution and digital data processing, making the construction of a standalone carbon dioxide-methane gas sensor possible.
Development of a cerebral circulation model for the automatic control of brain physiology.
Utsuki, T
2015-01-01
In various clinical guidelines of brain injury, intracranial pressure (ICP), cerebral blood flow (CBF) and brain temperature (BT) are essential targets for precise management for brain resuscitation. In addition, the integrated automatic control of BT, ICP, and CBF is required for improving therapeutic effects and reducing medical costs and staff burden. Thus, a new model of cerebral circulation was developed in this study for integrative automatic control. With this model, the CBF and cerebral perfusion pressure of a normal adult male were regionally calculated according to cerebrovascular structure, blood viscosity, blood distribution, CBF autoregulation, and ICP. The analysis results were consistent with physiological knowledge already obtained with conventional studies. Therefore, the developed model is potentially available for the integrative control of the physiological state of the brain as a reference model of an automatic control system, or as a controlled object in various control simulations.
Study on application of adaptive fuzzy control and neural network in the automatic leveling system
NASA Astrophysics Data System (ADS)
Xu, Xiping; Zhao, Zizhao; Lan, Weiyong; Sha, Lei; Qian, Cheng
2015-04-01
This paper discusses the adaptive fuzzy control and neural network BP algorithm in large flat automatic leveling control system application. The purpose is to develop a measurement system with a flat quick leveling, Make the installation on the leveling system of measurement with tablet, to be able to achieve a level in precision measurement work quickly, improve the efficiency of the precision measurement. This paper focuses on the automatic leveling system analysis based on fuzzy controller, Use of the method of combining fuzzy controller and BP neural network, using BP algorithm improve the experience rules .Construct an adaptive fuzzy control system. Meanwhile the learning rate of the BP algorithm has also been run-rate adjusted to accelerate convergence. The simulation results show that the proposed control method can effectively improve the leveling precision of automatic leveling system and shorten the time of leveling.
Tuyisenge, Viateur; Trebaul, Lena; Bhattacharjee, Manik; Chanteloup-Forêt, Blandine; Saubat-Guigui, Carole; Mîndruţă, Ioana; Rheims, Sylvain; Maillard, Louis; Kahane, Philippe; Taussig, Delphine; David, Olivier
2018-03-01
Intracranial electroencephalographic (iEEG) recordings contain "bad channels", which show non-neuronal signals. Here, we developed a new method that automatically detects iEEG bad channels using machine learning of seven signal features. The features quantified signals' variance, spatial-temporal correlation and nonlinear properties. Because the number of bad channels is usually much lower than the number of good channels, we implemented an ensemble bagging classifier known to be optimal in terms of stability and predictive accuracy for datasets with imbalanced class distributions. This method was applied on stereo-electroencephalographic (SEEG) signals recording during low frequency stimulations performed in 206 patients from 5 clinical centers. We found that the classification accuracy was extremely good: It increased with the number of subjects used to train the classifier and reached a plateau at 99.77% for 110 subjects. The classification performance was thus not impacted by the multicentric nature of data. The proposed method to automatically detect bad channels demonstrated convincing results and can be envisaged to be used on larger datasets for automatic quality control of iEEG data. This is the first method proposed to classify bad channels in iEEG and should allow to improve the data selection when reviewing iEEG signals. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.
Automatic Telescope Search for Extrasolar Planets
NASA Technical Reports Server (NTRS)
Henry, Gregory W.
1998-01-01
We are using automatic photoelectric telescopes at the Tennessee State University Center for Automated Space Science to search for planets around nearby stars in our galaxy. Over the past several years, wc have developed the capability to make extremely precise measurements of brightness changes in Sun-like stars with automatic telescopes. Extensive quality control and calibration measurements result in a precision of 0.l% for a single nightly observation and 0.0270 for yearly means, far better than previously thought possible with ground-based observations. We are able, for the first time, to trace brightness changes in Sun-like stars that are of similar amplitude to brightness changes in the Sun, whose changes can be observed only with space-based radiometers. Recently exciting discoveries of the first extrasolar planets have been announced, based on the detection of very small radial-velocity variations that imply the existence of planets in orbit around several Sun-like stars. Our precise brightness measurements have been crucial for the confirmation of these discoveries by helping to eliminate alternative explanations for the radial-velocity variations. With our automatic telescopes, we are also searching for transits of these planets across the disks of their stars in order to conclusively verify their existence. The detection of transits would provide the first direct measurements of the sizes, masses, and densities of these planets and, hence, information on their compositions and origins.
Lockheed L-1101 avionic flight control redundant systems
NASA Technical Reports Server (NTRS)
Throndsen, E. O.
1976-01-01
The Lockheed L-1011 automatic flight control systems - yaw stability augmentation and automatic landing - are described in terms of their redundancies. The reliability objectives for these systems are discussed and related to in-service experience. In general, the availability of the stability augmentation system is higher than the original design requirement, but is commensurate with early estimates. The in-service experience with automatic landing is not sufficient to provide verification of Category 3 automatic landing system estimated availability.
Schwein, Adeline; Kramer, Benjamin; Chinnadurai, Ponraj; Virmani, Neha; Walker, Sean; O'Malley, Marcia; Lumsden, Alan B; Bismuth, Jean
2018-04-01
Combining three-dimensional (3D) catheter control with electromagnetic (EM) tracking-based navigation significantly reduced fluoroscopy time and improved robotic catheter movement quality in a previous in vitro pilot study. The aim of this study was to expound on previous results and to expand the value of EM tracking with a novel feature, assistednavigation, allowing automatic catheter orientation and semiautomatic vessel cannulation. Eighteen users navigated a robotic catheter in an aortic aneurysm phantom using an EM guidewire and a modified 9F robotic catheter with EM sensors at the tip of both leader and sheath. All users cannulated two targets, the left renal artery and posterior gate, using four visualization modes: (1) Standard fluoroscopy (control). (2) 2D biplane fluoroscopy showing real-time virtual catheter localization and orientation from EM tracking. (3) 2D biplane fluoroscopy with novel EM assisted navigation allowing the user to define the target vessel. The robotic catheter orients itself automatically toward the target; the user then only needs to advance the guidewire following this predefined optimized path to catheterize the vessel. Then, while advancing the catheter over the wire, the assisted navigation automatically modifies catheter bending and rotation in order to ensure smooth progression, avoiding loss of wire access. (4) Virtual 3D representation of the phantom showing real-time virtual catheter localization and orientation. Standard fluoroscopy was always available; cannulation and fluoroscopy times were noted for every mode and target cannulation. Quality of catheter movement was assessed by measuring the number of submovements of the catheter using the 3D coordinates of the EM sensors. A t-test was used to compare the standard fluoroscopy mode against EM tracking modes. EM tracking significantly reduced the mean fluoroscopy time (P < .001) and the number of submovements (P < .02) for both cannulation tasks. For the posterior gate, mean cannulation time was also significantly reduced when using EM tracking (P < .001). The use of novel EM assisted navigation feature (mode 3) showed further reduced cannulation time for the posterior gate (P = .002) and improved quality of catheter movement for the left renal artery cannulation (P = .021). These results confirmed the findings of a prior study that highlighted the value of combining 3D robotic catheter control and 3D navigation to improve safety and efficiency of endovascular procedures. The novel EM assisted navigation feature augments the robotic master/slave concept with automated catheter orientation toward the target and shows promising results in reducing procedure time and improving catheter motion quality. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Effects of AEC chamber selection on patient dose and image quality.
Hawking, Nancy; Elmore, Angie
2009-01-01
To determine whether manipulation of the standard automatic exposure control (AEC) chamber selections reduces the patient's entrance skin exposure (ESE) without compromising image quality. Data for density and radiation dose were gathered at 2 clinical locations by exposing abdomen and pelvis phantoms to radiation using 3 AEC chamber selection configurations. ESE (skin dose) was measured using a multipurpose dosimeter. The experiment included both film-screen and computed radiography (CR) systems. For both phantoms, using the 2 outside chambers resulted in the lowest dose on the film-screen and CR systems. In general, optical density (OD) and exposure indicator (EI) remained within acceptable ranges and image quality was maintained using this chamber configuration. Using only the center chamber resulted in the highest dose increases and lowest image quality for film-screen and CR systems. When performing anteroposterior (AP) abdomen and AP pelvis examinations, radiographers can reduce patients' ESE and maintain image quality by selecting the 2 outside AEC chambers. Further research on AEC chamber selection should be conducted for additional anatomical regions.
Image quality comparisons of X-Omat RP, L and B films.
Van Dis, M L; Beck, F M
1991-08-01
The Eastman Kodak Company has recently developed a new film, X-Omat B (XB), designed to be interchangeable with X-Omat RP (XRP) film. The manufacturer claims the new film can be manually developed in half the time of other X-Omat films while automatic processing is unchanged. Three X-Omat film types were processed manually or automatically and the image qualities were evaluated. The XRP film had greater contrast than the XB and X-Omat L (XL) films when manually processed, and the XL film showed less contrast than the XB and XRP films when processed automatically. There was no difference in the subjective evaluation of the various film types and processing methods, and the XB film could be interchanged with XRP film in a simulated clinical situation.
NASA Technical Reports Server (NTRS)
Watson, D. M.; Hardy, G. H.; Warner, D. N., Jr.
1983-01-01
An automatic landing system was developed for the Augmentor Wing Jet STOL Research Airplane to establish the feasibility and examine the operating characteristics of a powered-lift STOL transport flying a steep, microwave landing system (MLS) glide slope to automatically land on a STOL port. The flight test results address the longitudinal aspects of automatic powered lift STOL airplane operation including glide slope tracking on the backside of the power curve, flare, and touchdown. Three different autoland control laws were evaluated to demonstrate the tradeoff between control complexity and the resulting performance. The flight test and simulation methodology used in developing conventional jet transport systems was applied to the powered-lift STOL airplane. The results obtained suggest that an automatic landing system for a powered-lift STOL airplane operating into an MLS-equipped STOL port is feasible. However, the airplane must be provided with a means of rapidly regulation lift to satisfactorily provide the glide slope tracking and control of touchdown sink rate needed for automatic landings.
System Proposal for Mass Transit Service Quality Control Based on GPS Data
Padrón, Gabino; Cristóbal, Teresa; Alayón, Francisco; Quesada-Arencibia, Alexis; García, Carmelo R.
2017-01-01
Quality is an essential aspect of public transport. In the case of regular public passenger transport by road, punctuality and regularity are criteria used to assess quality of service. Calculating metrics related to these criteria continuously over time and comprehensively across the entire transport network requires the handling of large amounts of data. This article describes a system for continuously and comprehensively monitoring punctuality and regularity. The system uses location data acquired continuously in the vehicles and automatically transferred for analysis. These data are processed intelligently by elements that are commonly used by transport operators: GPS-based tracking system, onboard computer and wireless networks for mobile data communications. The system was tested on a transport company, for which we measured the punctuality of one of the routes that it operates; the results are presented in this article. PMID:28621745
System Proposal for Mass Transit Service Quality Control Based on GPS Data.
Padrón, Gabino; Cristóbal, Teresa; Alayón, Francisco; Quesada-Arencibia, Alexis; García, Carmelo R
2017-06-16
Quality is an essential aspect of public transport. In the case of regular public passenger transport by road, punctuality and regularity are criteria used to assess quality of service. Calculating metrics related to these criteria continuously over time and comprehensively across the entire transport network requires the handling of large amounts of data. This article describes a system for continuously and comprehensively monitoring punctuality and regularity. The system uses location data acquired continuously in the vehicles and automatically transferred for analysis. These data are processed intelligently by elements that are commonly used by transport operators: GPS-based tracking system, onboard computer and wireless networks for mobile data communications. The system was tested on a transport company, for which we measured the punctuality of one of the routes that it operates; the results are presented in this article.
Automatically Grading Customer Confidence in a Formal Specification.
ERIC Educational Resources Information Center
Shukur, Zarina; Burke, Edmund; Foxley, Eric
1999-01-01
Describes an automatic grading system for a formal methods computer science course that is able to evaluate a formal specification written in the Z language. Quality is measured by considering first, specification correctness (syntax, semantics, and satisfaction of customer requirements), and second, specification maintainability (comparison of…
Hoffman, Steven J; Justicz, Victoria
2016-07-01
To develop and validate a method for automatically quantifying the scientific quality and sensationalism of individual news records. After retrieving 163,433 news records mentioning the Severe Acute Respiratory Syndrome (SARS) and H1N1 pandemics, a maximum entropy model for inductive machine learning was used to identify relationships among 500 randomly sampled news records that correlated with systematic human assessments of their scientific quality and sensationalism. These relationships were then computationally applied to automatically classify 10,000 additional randomly sampled news records. The model was validated by randomly sampling 200 records and comparing human assessments of them to the computer assessments. The computer model correctly assessed the relevance of 86% of news records, the quality of 65% of records, and the sensationalism of 73% of records, as compared to human assessments. Overall, the scientific quality of SARS and H1N1 news media coverage had potentially important shortcomings, but coverage was not too sensationalizing. Coverage slightly improved between the two pandemics. Automated methods can evaluate news records faster, cheaper, and possibly better than humans. The specific procedure implemented in this study can at the very least identify subsets of news records that are far more likely to have particular scientific and discursive qualities. Copyright © 2016 Elsevier Inc. All rights reserved.
Wang, Chunfei; Zhang, Guang; Wu, Taihu; Zhan, Ningbo; Wang, Yaling
2016-03-01
High-quality cardiopulmonary resuscitation contributes to cardiac arrest survival. The traditional chest compression (CC) standard, which neglects individual differences, uses unified standards for compression depth and compression rate in practice. In this study, an effective and personalized CC method for automatic mechanical compression devices is provided. We rebuild Charles F. Babbs' human circulation model with a coronary perfusion pressure (CPP) simulation module and propose a closed-loop controller based on a fuzzy control algorithm for CCs, which adjusts the CC depth according to the CPP. Compared with a traditional proportion-integration-differentiation (PID) controller, the performance of the fuzzy controller is evaluated in computer simulation studies. The simulation results demonstrate that the fuzzy closed-loop controller results in shorter regulation time, fewer oscillations and smaller overshoot than traditional PID controllers and outperforms the traditional PID controller for CPP regulation and maintenance.
Simulation to coating weight control for galvanizing
NASA Astrophysics Data System (ADS)
Wang, Junsheng; Yan, Zhang; Wu, Kunkui; Song, Lei
2013-05-01
Zinc coating weight control is one of the most critical issues for continuous galvanizing line. The process has the characteristic of variable-time large time delay, nonlinear, multivariable. It can result in seriously coating weight error and non-uniform coating. We develop a control system, which can automatically control the air knives pressure and its position to give a constant and uniform zinc coating, in accordance with customer-order specification through an auto-adaptive empirical model-based feed forward adaptive controller, and two model-free adaptive feedback controllers . The proposed models with controller were applied to continuous galvanizing line (CGL) at Angang Steel Works. By the production results, the precise and stability of the control model reduces over-coating weight and improves coating uniform. The product for this hot dip galvanizing line does not only satisfy the customers' quality requirement but also save the zinc consumption.
Martínez, T; Cordero, B; Medín, S; Sánchez Salmón, A
2011-01-01
To establish an automated procedure for the preparation of sodium fluoride (18)F injection using the resources available in our laboratory for the preparation of (18)FDG and to analyze the repercussion of the conditioning column of the fluoride ion entrapment on the characteristics of the final product. The sequence of an (18)FDG synthesis module prepared so that it traps the fluoride ion from the cyclotron in ion-exchange resin diluted with 0.9% sodium chloride. The final solution was dosified and sterilized in a final vial in an automatized dispensing module. Three different column conditioning protocols within the process were tested. Quality controls were run according to USP 32 and EurPh 6, adding control of ethanol levels of residual solvent and quality controls of the solution at 8 h post-preparation. Activation of the resin cartridges with ethanol and water was the chosen procedure, with fluoride ion trapping > 95% and pH around 7. Ethanol levels were < 5.000 ppm. Quality controls at 8 h indicated that the solution was in compliance with the USP 32 and EurPh 6 specifications. This is an easy, low-cost, reliable automated method for sodium fluoride preparation in PET facilities with existing equipment for (18)FDG synthesis and quality control. Copyright © 2010 Elsevier España, S.L. y SEMNIM. All rights reserved.
Office of Command Security Total Quality Management Plan
1989-07-01
outlines the Office of Command Security instruction for TQM implementation. Keywords: TQM (Total Quality Management ), DLA Office of Command Security, Continuous process improvement, Automatic data processing security.
System for computer controlled shifting of an automatic transmission
Patil, Prabhakar B.
1989-01-01
In an automotive vehicle having an automatic transmission that driveably connects a power source to the driving wheels, a method to control the application of hydraulic pressure to a clutch, whose engagement produces an upshift and whose disengagement produces a downshift, the speed of the power source, and the output torque of the transmission. The transmission output shaft torque and the power source speed are the controlled variables. The commanded power source torque and commanded hydraulic pressure supplied to the clutch are the control variables. A mathematical model is formulated that describes the kinematics and dynamics of the powertrain before, during and after a gear shift. The model represents the operating characteristics of each component and the structural arrangement of the components within the transmission being controlled. Next, a close loop feedback control is developed to determine the proper control law or compensation strategy to achieve an acceptably smooth gear ratio change, one in which the output torque disturbance is kept to a minimum and the duration of the shift is minimized. Then a computer algorithm simulating the shift dynamics employing the mathematical model is used to study the effects of changes in the values of the parameters established from a closed loop control of the clutch hydraulic and the power source torque on the shift quality. This computer simulation is used also to establish possible shift control strategies. The shift strategies determine from the prior step are reduced to an algorithm executed by a computer to control the operation of the power source and the transmission.
Closed loop computer control for an automatic transmission
Patil, Prabhakar B.
1989-01-01
In an automotive vehicle having an automatic transmission that driveably connects a power source to the driving wheels, a method to control the application of hydraulic pressure to a clutch, whose engagement produces an upshift and whose disengagement produces a downshift, the speed of the power source, and the output torque of the transmission. The transmission output shaft torque and the power source speed are the controlled variables. The commanded power source torque and commanded hydraulic pressure supplied to the clutch are the control variables. A mathematical model is formulated that describes the kinematics and dynamics of the powertrain before, during and after a gear shift. The model represents the operating characteristics of each component and the structural arrangement of the components within the transmission being controlled. Next, a close loop feedback control is developed to determine the proper control law or compensation strategy to achieve an acceptably smooth gear ratio change, one in which the output torque disturbance is kept to a minimum and the duration of the shift is minimized. Then a computer algorithm simulating the shift dynamics employing the mathematical model is used to study the effects of changes in the values of the parameters established from a closed loop control of the clutch hydraulic and the power source torque on the shift quality. This computer simulation is used also to establish possible shift control strategies. The shift strategies determined from the prior step are reduced to an algorithm executed by a computer to control the operation of the power source and the transmission.
An efficient visualization method for analyzing biometric data
NASA Astrophysics Data System (ADS)
Rahmes, Mark; McGonagle, Mike; Yates, J. Harlan; Henning, Ronda; Hackett, Jay
2013-05-01
We introduce a novel application for biometric data analysis. This technology can be used as part of a unique and systematic approach designed to augment existing processing chains. Our system provides image quality control and analysis capabilities. We show how analysis and efficient visualization are used as part of an automated process. The goal of this system is to provide a unified platform for the analysis of biometric images that reduce manual effort and increase the likelihood of a match being brought to an examiner's attention from either a manual or lights-out application. We discuss the functionality of FeatureSCOPE™ which provides an efficient tool for feature analysis and quality control of biometric extracted features. Biometric databases must be checked for accuracy for a large volume of data attributes. Our solution accelerates review of features by a factor of up to 100 times. Review of qualitative results and cost reduction is shown by using efficient parallel visual review for quality control. Our process automatically sorts and filters features for examination, and packs these into a condensed view. An analyst can then rapidly page through screens of features and flag and annotate outliers as necessary.
Automated Data Quality Assurance using OGC Sensor Web Enablement Frameworks for Marine Observatories
NASA Astrophysics Data System (ADS)
Toma, Daniel; Bghiel, Ikram; del Rio, Joaquin; Hidalgo, Alberto; Carreras, Normandino; Manuel, Antoni
2014-05-01
Over the past years, environmental sensors have continuously improved by becoming smaller, cheaper, and more intelligent. Therefore, many sensor networks are increasingly deployed to monitor our environment. But due to the large number of sensor manufacturers, accompanying protocols and data encoding, automated integration and data quality assurance of diverse sensors in an observing systems is not straightforward, requiring development of data management code and manual tedious configuration. However, over the past few years it has been demonstrated that Open-Geospatial Consortium (OGC) frameworks can enable web services with fully-described sensor systems, including data processing, sensor characteristics and quality control tests and results. So far, the SWE framework does not describe how to integrate sensors on-the-fly with minimal human intervention. The data management software which enables access to sensors, data processing and quality control tests has to be implemented and the results have to be manually mapped to the SWE models. In this contribution, we describe a Sensor Plug & Play infrastructure for the Sensor Web by combining (1) OGC PUCK protocol - a simple standard embedded instrument protocol to store and retrieve directly from the devices the declarative description of sensor characteristics and quality control tests, (2) an automatic mechanism for data processing and quality control tests underlying the Sensor Web - the Sensor Interface Descriptor (SID) concept, as well as (3) a model for the declarative description of sensor which serves as a generic data management mechanism - designed as a profile and extension of OGC SWE's SensorML standard. We implement and evaluate our approach by applying it to the OBSEA Observatory, and can be used to demonstrate the ability to assess data quality for temperature, salinity, air pressure and wind speed and direction observations off the coast of Garraf, in the north-eastern Spain.
Computer vision based nacre thickness measurement of Tahitian pearls
NASA Astrophysics Data System (ADS)
Loesdau, Martin; Chabrier, Sébastien; Gabillon, Alban
2017-03-01
The Tahitian Pearl is the most valuable export product of French Polynesia contributing with over 61 million Euros to more than 50% of the total export income. To maintain its excellent reputation on the international market, an obligatory quality control for every pearl deemed for exportation has been established by the local government. One of the controlled quality parameters is the pearls nacre thickness. The evaluation is currently done manually by experts that are visually analyzing X-ray images of the pearls. In this article, a computer vision based approach to automate this procedure is presented. Even though computer vision based approaches for pearl nacre thickness measurement exist in the literature, the very specific features of the Tahitian pearl, namely the large shape variety and the occurrence of cavities, have so far not been considered. The presented work closes the. Our method consists of segmenting the pearl from X-ray images with a model-based approach, segmenting the pearls nucleus with an own developed heuristic circle detection and segmenting possible cavities with region growing. Out of the obtained boundaries, the 2-dimensional nacre thickness profile can be calculated. A certainty measurement to consider imaging and segmentation imprecisions is included in the procedure. The proposed algorithms are tested on 298 manually evaluated Tahitian pearls, showing that it is generally possible to automatically evaluate the nacre thickness of Tahitian pearls with computer vision. Furthermore the results show that the automatic measurement is more precise and faster than the manual one.
Method for enhanced control of welding processes
Sheaffer, Donald A.; Renzi, Ronald F.; Tung, David M.; Schroder, Kevin
2000-01-01
Method and system for producing high quality welds in welding processes, in general, and gas tungsten arc (GTA) welding, in particular by controlling weld penetration. Light emitted from a weld pool is collected from the backside of a workpiece by optical means during welding and transmitted to a digital video camera for further processing, after the emitted light is first passed through a short wavelength pass filter to remove infrared radiation. By filtering out the infrared component of the light emitted from the backside weld pool image, the present invention provides for the accurate determination of the weld pool boundary. Data from the digital camera is fed to an imaging board which focuses on a 100.times.100 pixel portion of the image. The board performs a thresholding operation and provides this information to a digital signal processor to compute the backside weld pool dimensions and area. This information is used by a control system, in a dynamic feedback mode, to automatically adjust appropriate parameters of a welding system, such as the welding current, to control weld penetration and thus, create a uniform weld bead and high quality weld.
46 CFR 63.01-3 - Scope and applicability.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY... automatic auxiliary boilers, automatic heating boilers, automatic waste heat boilers, donkey boilers... control systems) used for the generation of steam and/or oxidation of ordinary waste materials and garbage...
46 CFR 63.01-3 - Scope and applicability.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY... automatic auxiliary boilers, automatic heating boilers, automatic waste heat boilers, donkey boilers... control systems) used for the generation of steam and/or oxidation of ordinary waste materials and garbage...
Application of nonlinear transformations to automatic flight control
NASA Technical Reports Server (NTRS)
Meyer, G.; Su, R.; Hunt, L. R.
1984-01-01
The theory of transformations of nonlinear systems to linear ones is applied to the design of an automatic flight controller for the UH-1H helicopter. The helicopter mathematical model is described and it is shown to satisfy the necessary and sufficient conditions for transformability. The mapping is constructed, taking the nonlinear model to canonical form. The performance of the automatic control system in a detailed simulation on the flight computer is summarized.
SU-E-I-68: Practical Considerations On Implementation of the Image Gently Pediatric CT Protocols
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, J; Adams, C; Lumby, C
Purpose: One limitation associated with the Image Gently pediatric CT protocols is practical implementation of the recommended manual techniques. Inconsistency as a result of different practice is a possibility among technologist. An additional concern is the added risk of data error that would result in over or underexposure. The Automatic Exposure Control (AEC) features automatically reduce radiation for children. However, they do not work efficiently for the patients of very small size and relative large size. This study aims to implement the Image Gently pediatric CT protocols in the practical setting while maintaining the use of AEC features for pediatricmore » patients of varying size. Methods: Anthropomorphological abdomen phantoms were scanned in a CT scanner using the Image Gently pediatric protocols, the AEC technique with a fixed adult baseline, and automatic protocols with various baselines. The baselines were adjusted corresponding to patient age, weight and posterioranterior thickness to match the Image Gently pediatric CT manual techniques. CTDIvol was recorded for each examination. Image noise was measured and recorded for image quality comparison. Clinical images were evaluated by pediatric radiologists. Results: By adjusting vendor default baselines used in the automatic techniques, radiation dose and image quality can match those of the Image Gently manual techniques. In practice, this can be achieved by dividing pediatric patients into three major groups for technologist reference: infant, small child, and large child. Further division can be done but will increase the number of CT protocols. For each group, AEC can efficiently adjust acquisition techniques for children. This implementation significantly overcomes the limitation of the Image Gently manual techniques. Conclusion: Considering the effectiveness in clinical practice, Image Gently Pediatric CT protocols can be implemented in accordance with AEC techniques, with adjusted baselines, to achieve the goal of providing the most appropriate radiation dose for pediatric patients of varying sizes.« less
Automatic loudness control in short-form content for broadcasting.
Pires, Leandro da S; Vieira, Maurílio N; Yehia, Hani C
2017-03-01
During the early years of the International Telecommunication Union (ITU) loudness calculation standard for sound broadcasting [ITU-R (2006), Rec. BS Series, 1770], the need for additional loudness descriptors to evaluate short-form content, such as commercials and live inserts, was identified. This work proposes a loudness control scheme to prevent loudness jumps, which can bother audiences. It employs short-form content audio detection and dynamic range processing methods for the maximum loudness level criteria. Detection is achieved by combining principal component analysis for dimensionality reduction and support vector machines for binary classification. Subsequent processing is based on short-term loudness integrators and Hilbert transformers. The performance was assessed using quality classification metrics and demonstrated through a loudness control example.
Object-oriented controlled-vocabulary translator using TRANSOFT + HyperPAD.
Moore, G W; Berman, J J
1991-01-01
Automated coding of surgical pathology reports is demonstrated. This public-domain translation software operates on surgical pathology files, extracting diagnoses and assigning codes in a controlled medical vocabulary, such as SNOMED. Context-sensitive translation algorithms are employed, and syntactically correct diagnostic items are produced that are matched with controlled vocabulary. English-language surgical pathology reports, accessioned over one year at the Baltimore Veterans Affairs Medical Center, were translated. With an interface to a larger hospital information system, all natural language pathology reports are automatically rendered as topography and morphology codes. This translator frees the pathologist from the time-intensive task of personally coding each report, and may be used to flag certain diagnostic categories that require specific quality assurance actions.
Object-oriented controlled-vocabulary translator using TRANSOFT + HyperPAD.
Moore, G. W.; Berman, J. J.
1991-01-01
Automated coding of surgical pathology reports is demonstrated. This public-domain translation software operates on surgical pathology files, extracting diagnoses and assigning codes in a controlled medical vocabulary, such as SNOMED. Context-sensitive translation algorithms are employed, and syntactically correct diagnostic items are produced that are matched with controlled vocabulary. English-language surgical pathology reports, accessioned over one year at the Baltimore Veterans Affairs Medical Center, were translated. With an interface to a larger hospital information system, all natural language pathology reports are automatically rendered as topography and morphology codes. This translator frees the pathologist from the time-intensive task of personally coding each report, and may be used to flag certain diagnostic categories that require specific quality assurance actions. PMID:1807773
A PLM-based automated inspection planning system for coordinate measuring machine
NASA Astrophysics Data System (ADS)
Zhao, Haibin; Wang, Junying; Wang, Boxiong; Wang, Jianmei; Chen, Huacheng
2006-11-01
With rapid progress of Product Lifecycle Management (PLM) in manufacturing industry, automatic generation of inspection planning of product and the integration with other activities in product lifecycle play important roles in quality control. But the techniques for these purposes are laggard comparing with techniques of CAD/CAM. Therefore, an automatic inspection planning system for Coordinate Measuring Machine (CMM) was developed to improve the automatization of measuring based on the integration of inspection system in PLM. Feature information representation is achieved based on a PLM canter database; measuring strategy is optimized through the integration of multi-sensors; reasonable number and distribution of inspection points are calculated and designed with the guidance of statistic theory and a synthesis distribution algorithm; a collision avoidance method is proposed to generate non-collision inspection path with high efficiency. Information mapping is performed between Neutral Interchange Files (NIFs), such as STEP, DML, DMIS, XML, etc., to realize information integration with other activities in the product lifecycle like design, manufacturing and inspection execution, etc. Simulation was carried out to demonstrate the feasibility of the proposed system. As a result, the inspection process is becoming simpler and good result can be got based on the integration in PLM.
Approaches to the automatic generation and control of finite element meshes
NASA Technical Reports Server (NTRS)
Shephard, Mark S.
1987-01-01
The algorithmic approaches being taken to the development of finite element mesh generators capable of automatically discretizing general domains without the need for user intervention are discussed. It is demonstrated that because of the modeling demands placed on a automatic mesh generator, all the approaches taken to date produce unstructured meshes. Consideration is also given to both a priori and a posteriori mesh control devices for automatic mesh generators as well as their integration with geometric modeling and adaptive analysis procedures.
Research and Development of Fully Automatic Alien Smoke Stack and Packaging System
NASA Astrophysics Data System (ADS)
Yang, Xudong; Ge, Qingkuan; Peng, Tao; Zuo, Ping; Dong, Weifu
2017-12-01
The problem of low efficiency of manual sorting packaging for the current tobacco distribution center, which developed a set of safe efficient and automatic type of alien smoke stack and packaging system. The functions of fully automatic alien smoke stack and packaging system adopt PLC control technology, servo control technology, robot technology, image recognition technology and human-computer interaction technology. The characteristics, principles, control process and key technology of the system are discussed in detail. Through the installation and commissioning fully automatic alien smoke stack and packaging system has a good performance and has completed the requirements for shaped cigarette.
Automatic inoculating apparatus. [includes movable carraige, drive motor, and swabbing motor
NASA Technical Reports Server (NTRS)
Wilkins, J. R.; Mills, S. M. (Inventor)
1974-01-01
An automatic inoculating apparatus for agar trays is described and using a simple inoculating element, such as a cotton swab or inoculating loop. The apparatus includes a movable carriage for supporting the tray to be inoculated, a drive motor for moving the tray along a trackway, and a swabbing motor for automatically swabbing the tray during the movement. An actuator motor controls lowering of the inoculating element onto the tray and lifting of the inoculating element. An electrical control system, including limit microswitches, enables automatic control of the actuator motor and return of the carriage to the initial position after inoculating is completed.
14 CFR 33.87 - Endurance test.
Code of Federal Regulations, 2011 CFR
2011-01-01
... particular engine being tested. (2) Any automatic engine control that is part of the engine must control the engine during the endurance test except for operations where automatic control is normally overridden by manual control or where manual control is otherwise specified for a particular test run. (3) Except as...
14 CFR 33.87 - Endurance test.
Code of Federal Regulations, 2012 CFR
2012-01-01
... particular engine being tested. (2) Any automatic engine control that is part of the engine must control the engine during the endurance test except for operations where automatic control is normally overridden by manual control or where manual control is otherwise specified for a particular test run. (3) Except as...
Machine-Aided Translation: From Terminology Banks to Interactive Translation Systems.
ERIC Educational Resources Information Center
Greenfield, Concetta C.; Serain, Daniel
The rapid growth of the need for technical translations in recent years has led specialists to utilize computer technology to improve the efficiency and quality of translation. The two approaches considered were automatic translation and terminology banks. Since the results of fully automatic translation were considered unsatisfactory by various…
Aspects of quality insurance in digitizing historical climate data in Germany
NASA Astrophysics Data System (ADS)
Mächel, H.; Behrends, J.; Kapala, A.
2010-09-01
This contribution presents some of the problems and offers solutions regarding the digitization of historical meteorological data, and explains the need for verification and quality control. For the assessment of changes in climate extremes, long-term and complete observational records with a high temporal resolution are needed. However, in most countries, including Germany, such climate data are rare. Therefore, in 2005, the German Weather Service launched a project to inventory and digitize historical daily climatic records in cooperation with the Meteorological Institute of the University of Bonn. Experience with Optical Character Recognition (OCR) show that it is only of very limited use, as even printed tables (e.g. yearbooks) are not sufficiently recognized (10-20% error). In hand-written records, the recognition rate is about 50%. By comparing daily and monthly values, it is possible to auto-detect errors, but they can not be automatically corrected, since there is often more than one error per month. These erroneous data must then be controlled manually on an individual basis, which is significantly more error-prone than direct manual input. Therefore, both precipitation and climate station data are digitized manually. The time required to digitize one year of precipitation data (including the recording of daily precipitation amount and type, snow amount and type, and weather events such as thunder storms, fog, etc.) is equivalent to about five hours for one year of data. This involves manually typing, reformatting and quality control of the digitized data, as well as creating a digital photograph. For climate stations with three observations per day, the working time is 30-50 hours for one year of data, depending on the number of parameters and the condition of the documents. Several other problems occur when creating the digital records from historical observational data, some of which are listed below. Older records often used varying units and different conventions. For example, a value of 100 was added to the observed temperatures to avoid negative values. Furthermore, because standardization of the observations was very low when measurements began up to 200 years ago, the data often reflect a greater part of non-climatic influences. Varying daily observation times make it difficult to calculate a representative daily value. Even unconventional completed tables cost labor and requires experienced and trained staff. Data homogenization as well as both manual and automatic quality control may address some of these problems.
Application of a movable active vibration control system on a floating raft
NASA Astrophysics Data System (ADS)
Wang, Zhen; Mak, Cheuk Ming
2018-02-01
This paper presents a theoretical study of an inertial actuator connected to an accelerometer by a local feedback loop for active vibration control on a floating raft. On the criterion of the minimum power transmission from the vibratory machines to the flexible foundation in the floating raft, the best mounting positions for the inertial actuator on the intermediate mass of the floating raft are investigated. Simulation results indicate that the best mounting positions for the inertial actuator vary with frequency. To control time-varying excitations of vibratory machines on a floating raft effectively, an automatic control system based on real-time measurement of a cost function and automatically searching the best mounting position of the inertial actuator is proposed. To the best of our knowledge, it is the first time that an automatic control system is proposed to move an actuator automatically for controlling a time-varying excitation.
A device for automatic photoelectric control of the analytical gap for emission spectrographs
Dietrich, John A.; Cooley, Elmo F.; Curry, Kenneth J.
1977-01-01
A photoelectric device has been built that automatically controls the analytical gap between electrodes during excitation period. The control device allows for precise control of the analytical gap during the arcing process of samples, resulting in better precision of analysis.
Sabet, Mahsheed; O'Connor, Daryl J.; Greer, Peter B.
2011-01-01
There have been several manual, semi‐automatic and fully‐automatic methods proposed for verification of the position of mechanical isocenter as part of comprehensive quality assurance programs required for linear accelerator‐based stereotactic radiosurgery/radiotherapy (SRS/SRT) treatments. In this paper, a systematic review has been carried out to discuss the present methods for isocenter verification and compare their characteristics, to help physicists in making a decision on selection of their quality assurance routine. PACS numbers: 87.53.Ly, 87.56.Fc, 87.56.‐v PMID:22089022
A Personalized Health Information Retrieval System
Wang, Yunli; Liu, Zhenkai
2005-01-01
Consumers face barriers when seeking health information on the Internet. A Personalized Health Information Retrieval System (PHIRS) is proposed to recommend health information for consumers. The system consists of four modules: (1) User modeling module captures user’s preference and health interests; (2) Automatic quality filtering module identifies high quality health information; (3) Automatic text difficulty rating module classifies health information into professional or patient educational materials; and (4) User profile matching module tailors health information for individuals. The initial results show that PHIRS could assist consumers with simple search strategies. PMID:16779435
Innocente, N; Biasutti, M
2013-02-01
Montasio cheese is a typical Italian semi-hard, semi-cooked cheese produced in northeastern Italy from unpasteurized (raw or thermised) cow milk. The Protected Designation of Origin label regulations for Montasio cheese require that local milk be used from twice-daily milking. The number of farms milking with automatic milking systems (AMS) has increased rapidly in the last few years in the Montasio production area. The objective of this study was to evaluate the effects of a variation in milking frequency, associated with the adoption of an automatic milking system, on milk quality and on the specific characteristics of Montasio cheese. Fourteen farms were chosen, all located in the Montasio production area, with an average herd size of 60 (Simmental, Holstein-Friesian, and Brown Swiss breeds). In 7 experimental farms, the cows were milked 3 times per day with an AMS, whereas in the other 7 control farms, cows were milked twice daily in conventional milking parlors (CMP). The study showed that the main components, the hygienic quality, and the cheese-making features of milk were not affected by the milking system adopted. In fact, the control and experimental milks did not reveal a statistically significant difference in fat, protein, and lactose contents; in the casein index; or in the HPLC profiles of casein and whey protein fractions. Milk from farms that used an AMS always showed somatic cell counts and total bacterial counts below the legal limits imposed by European Union regulations for raw milk. Finally, bulk milk clotting characteristics (clotting time, curd firmness, and time to curd firmness of 20mm) did not differ between milk from AMS and milk from CMP. Montasio cheese was made from milk collected from the 2 groups of farms milking either with AMS or with CMP. Three different cheese-making trials were performed during the year at different times. As expected, considering the results of the milk analysis, the moisture, fat, and protein contents of the experimental and control cheeses were comparable. The milking system was not seen to significantly affect the biochemical processes associated with ripening. In fact, all cheeses showed a normal proteolysis trend and a characteristic volatile compound profile during aging. Therefore, the milking system does not appear to modify the distinctive characteristics of this cheese that remain dependent on the area and methodology of production. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Mcgehee, C. R.
1986-01-01
A study was conducted under Drones for Aerodynamic and Structural Testing (DAST) program to accomplish the final design and hardware fabrication for four active control systems compatible with and ready for installation in the NASA Aeroelastic Research Wing No. 2 (ARW-2) and Firebee II drone flight test vehicle. The wing structure was designed so that Active Control Systems (ACS) are required in the normal flight envelope by integrating control system design with aerodynamics and structure technologies. The DAST ARW-2 configuration uses flutter suppression, relaxed static stability, and gust and maneuver load alleviation ACS systems, and an automatic flight control system. Performance goals and criteria were applied to individual systems and the systems collectively to assure that vehicle stability margins, flutter margins, flying qualities and load reductions are achieved.
Improvement in vehicle agility and stability by G-Vectoring control
NASA Astrophysics Data System (ADS)
Yamakado, Makoto; Takahashi, Jyunya; Saito, Shinjiro; Yokoyama, Atsushi; Abe, Masato
2010-12-01
We extracted a trade-off strategy between longitudinal traction/braking force and cornering force by using jerk information through observing an expert driver's voluntary braking and turning action. Using the expert driver's strategy, we developed a new control concept, called 'G-Vectoring control', which is an automatic longitudinal acceleration control (No DYC) in accordance with the vehicle's lateral jerk caused by the driver's steering manoeuvres. With the control, the direction of synthetic acceleration (G) changes seamlessly (i.e. vectoring). The improvements in vehicle agility and stability were evaluated by theoretical analysis and through computer simulation. We then introduced a 'G-Vectoring' equipped test vehicle realised by brake-by-wire technology and executed a detailed examination on a test track. We have confirmed that the vehicle motion in view of both handling and ride quality has improved dramatically.
Adaptive Neural Network Algorithm for Power Control in Nuclear Power Plants
NASA Astrophysics Data System (ADS)
Masri Husam Fayiz, Al
2017-01-01
The aim of this paper is to design, test and evaluate a prototype of an adaptive neural network algorithm for the power controlling system of a nuclear power plant. The task of power control in nuclear reactors is one of the fundamental tasks in this field. Therefore, researches are constantly conducted to ameliorate the power reactor control process. Currently, in the Department of Automation in the National Research Nuclear University (NRNU) MEPhI, numerous studies are utilizing various methodologies of artificial intelligence (expert systems, neural networks, fuzzy systems and genetic algorithms) to enhance the performance, safety, efficiency and reliability of nuclear power plants. In particular, a study of an adaptive artificial intelligent power regulator in the control systems of nuclear power reactors is being undertaken to enhance performance and to minimize the output error of the Automatic Power Controller (APC) on the grounds of a multifunctional computer analyzer (simulator) of the Water-Water Energetic Reactor known as Vodo-Vodyanoi Energetichesky Reaktor (VVER) in Russian. In this paper, a block diagram of an adaptive reactor power controller was built on the basis of an intelligent control algorithm. When implementing intelligent neural network principles, it is possible to improve the quality and dynamic of any control system in accordance with the principles of adaptive control. It is common knowledge that an adaptive control system permits adjusting the controller’s parameters according to the transitions in the characteristics of the control object or external disturbances. In this project, it is demonstrated that the propitious options for an automatic power controller in nuclear power plants is a control system constructed on intelligent neural network algorithms.
Automatic assessment of voice quality according to the GRBAS scale.
Sáenz-Lechón, Nicolás; Godino-Llorente, Juan I; Osma-Ruiz, Víctor; Blanco-Velasco, Manuel; Cruz-Roldán, Fernando
2006-01-01
Nowadays, the most extended techniques to measure the voice quality are based on perceptual evaluation by well trained professionals. The GRBAS scale is a widely used method for perceptual evaluation of voice quality. The GRBAS scale is widely used in Japan and there is increasing interest in both Europe and the United States. However, this technique needs well-trained experts, and is based on the evaluator's expertise, depending a lot on his own psycho-physical state. Furthermore, a great variability in the assessments performed from one evaluator to another is observed. Therefore, an objective method to provide such measurement of voice quality would be very valuable. In this paper, the automatic assessment of voice quality is addressed by means of short-term Mel cepstral parameters (MFCC), and learning vector quantization (LVQ) in a pattern recognition stage. Results show that this approach provides acceptable results for this purpose, with accuracy around 65% at the best.
Automatic Control Of Length Of Welding Arc
NASA Technical Reports Server (NTRS)
Iceland, William F.
1991-01-01
Nonlinear relationships among current, voltage, and length stored in electronic memory. Conceptual microprocessor-based control subsystem maintains constant length of welding arc in gas/tungsten arc-welding system, even when welding current varied. Uses feedback of current and voltage from welding arc. Directs motor to set position of torch according to previously measured relationships among current, voltage, and length of arc. Signal paths marked "calibration" or "welding" used during those processes only. Other signal paths used during both processes. Control subsystem added to existing manual or automatic welding system equipped with automatic voltage control.
Automatic control study of the icing research tunnel refrigeration system
NASA Technical Reports Server (NTRS)
Kieffer, Arthur W.; Soeder, Ronald H.
1991-01-01
The Icing Research Tunnel (IRT) at the NASA Lewis Research Center is a subsonic, closed-return atmospheric tunnel. The tunnel includes a heat exchanger and a refrigeration plant to achieve the desired air temperature and a spray system to generate the type of icing conditions that would be encountered by aircraft. At the present time, the tunnel air temperature is controlled by manual adjustment of freon refrigerant flow control valves. An upgrade of this facility calls for these control valves to be adjusted by an automatic controller. The digital computer simulation of the IRT refrigeration plant and the automatic controller that was used in the simulation are discussed.
MeSH indexing based on automatically generated summaries.
Jimeno-Yepes, Antonio J; Plaza, Laura; Mork, James G; Aronson, Alan R; Díaz, Alberto
2013-06-26
MEDLINE citations are manually indexed at the U.S. National Library of Medicine (NLM) using as reference the Medical Subject Headings (MeSH) controlled vocabulary. For this task, the human indexers read the full text of the article. Due to the growth of MEDLINE, the NLM Indexing Initiative explores indexing methodologies that can support the task of the indexers. Medical Text Indexer (MTI) is a tool developed by the NLM Indexing Initiative to provide MeSH indexing recommendations to indexers. Currently, the input to MTI is MEDLINE citations, title and abstract only. Previous work has shown that using full text as input to MTI increases recall, but decreases precision sharply. We propose using summaries generated automatically from the full text for the input to MTI to use in the task of suggesting MeSH headings to indexers. Summaries distill the most salient information from the full text, which might increase the coverage of automatic indexing approaches based on MEDLINE. We hypothesize that if the results were good enough, manual indexers could possibly use automatic summaries instead of the full texts, along with the recommendations of MTI, to speed up the process while maintaining high quality of indexing results. We have generated summaries of different lengths using two different summarizers, and evaluated the MTI indexing on the summaries using different algorithms: MTI, individual MTI components, and machine learning. The results are compared to those of full text articles and MEDLINE citations. Our results show that automatically generated summaries achieve similar recall but higher precision compared to full text articles. Compared to MEDLINE citations, summaries achieve higher recall but lower precision. Our results show that automatic summaries produce better indexing than full text articles. Summaries produce similar recall to full text but much better precision, which seems to indicate that automatic summaries can efficiently capture the most important contents within the original articles. The combination of MEDLINE citations and automatically generated summaries could improve the recommendations suggested by MTI. On the other hand, indexing performance might be dependent on the MeSH heading being indexed. Summarization techniques could thus be considered as a feature selection algorithm that might have to be tuned individually for each MeSH heading.
Wilson, W B; Haus, A G; Nierman, C; Lillie, R; Batz, T; Moore, R
1993-01-01
In medical imaging, the temperature of the developer solution in the film processor affects film speed (radiation dose), film contrast, and film base plus fog. The National Council on Radiation Protection and Measurement (NCRP) Report 99 on Quality Assurance, and the American College of Radiology (ACR) Mammography Quality Control Manual for Radiologic Technologists, indicate that the developer temperature should be within +/- 0.5 degree F (+/- 0.3 degree C) of that recommended by the manufacturer for the specific film/developer combination being used. The accuracy and repeatability of the thermometer is most important. This paper describes the requirements of a thermometer for measuring the temperature of the developer solution and suggests an inexpensive but accurate device for doing so.
An experimental study of cutting performances in machining of nimonic super alloy GH2312
NASA Astrophysics Data System (ADS)
Du, Jinfu; Wang, Xi; Xu, Min; Mao, Jin; Zhao, Xinglong
2018-05-01
Nimonic super alloy are extensively used in the aerospace industry because of its unique properties. As they are quite costly and difficult to machine, the machining tool is easy to get worn. To solve the problem, an experiment was carried out on a numerical control slitting automatic lathe to analysis the tool wearing conditions and parts' surface quality of nimonic super alloy GH2132 under different cutters. The selection of suitable cutter, reasonable cutting data and cutting speed is obtained and some conclusions are made. The excellent coating tool, compared with other hard alloy cutters, along with suitable cutting data will greatly improve the production efficiency and product quality, it can completely meet the process of nimonic super alloy GH2312.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng, Y; Huang, Z; Lo, S
2015-06-15
Purpose: To improve Gamma Knife SRS treatment efficiency for brain metastases and compare the differences of treatment time and radiobiological effects between two different planning methods of automatic filling and manual placement of shots with inverse planning. Methods: T1-weighted MRI images with gadolinium contrast from five patients with a single brain metastatic-lesion were used in this retrospective study. Among them, two were from primary breast cancer, two from primary melanoma cancer and one from primary prostate cancer. For each patient, two plans were generated in Leksell GammaPlan10.1.1 for radiosurgical treatment with a Leksell GammaKnife Perfexion machine: one with automatic filling,more » automatic sector configuration and inverse optimization (Method1); and the other with manual placement of shots, manual setup of collimator sizes, manual setup of sector blocking and inverse optimization (Method2). Dosimetric quality of the plans was evaluated with parameters of Coverage, Selectivity, Gradient-Index and DVH. Beam-on Time, Number-of-Shots and Tumor Control Probability(TCP) were compared for the two plans while keeping their dosimetric quality very similar. Relative reduction of Beam-on Time and Number-of-Shots were calculated as the ratios among the two plans and used for quantitative analysis. Results: With very similar dosimetric and radiobiological plan quality, plans created with Method 2 had significantly reduced treatment time. Relative reduction of Beam-on Time ranged from 20% to 51 % (median:29%,p=0.001), and reduction of Number-of-Shots ranged from 5% to 67% (median:40%,p=0.0002), respectively. Time of plan creation for Method1 and Method2 was similar, approximately 20 minutes, excluding the time for tumor delineation. TCP calculated for the tumors from differential DVHs did not show significant difference between the two plans (p=0.35). Conclusion: The method of manual setup combined with inverse optimization in LGP for treatment of brain metastatic lesions with the Perfexion can achieve significantly higher time efficiency without degrading treatment quality.« less
Grinding Parts For Automatic Welding
NASA Technical Reports Server (NTRS)
Burley, Richard K.; Hoult, William S.
1989-01-01
Rollers guide grinding tool along prospective welding path. Skatelike fixture holds rotary grinder or file for machining large-diameter rings or ring segments in preparation for welding. Operator grasps handles to push rolling fixture along part. Rollers maintain precise dimensional relationship so grinding wheel cuts precise depth. Fixture-mounted grinder machines surface to quality sufficient for automatic welding; manual welding with attendant variations and distortion not necessary. Developed to enable automatic welding of parts, manual welding of which resulted in weld bead permeated with microscopic fissures.
A Development of Automatic Audit System for Written Informed Consent using Machine Learning.
Yamada, Hitomi; Takemura, Tadamasa; Asai, Takahiro; Okamoto, Kazuya; Kuroda, Tomohiro; Kuwata, Shigeki
2015-01-01
In Japan, most of all the university and advanced hospitals have implemented both electronic order entry systems and electronic charting. In addition, all medical records are subjected to inspector audit for quality assurance. The record of informed consent (IC) is very important as this provides evidence of consent from the patient or patient's family and health care provider. Therefore, we developed an automatic audit system for a hospital information system (HIS) that is able to evaluate IC automatically using machine learning.
Roberts, Walter; Fillmore, Mark T.; Milich, Richard
2011-01-01
Researchers in the cognitive sciences recognize a fundamental distinction between automatic and intentional mechanisms of inhibitory control. The use of eye-tracking tasks to assess selective attention has led to a better understanding of this distinction in specific populations such as children with attention-deficit/hyperactivity disorder (ADHD). This study examined automatic and intentional inhibitory control mechanisms in adults with ADHD using a saccadic interference (SI) task and a delayed ocular response (DOR) task. Thirty adults with ADHD were compared to 27 comparison adults on measures of inhibitory control. The DOR task showed that adults with ADHD were less able than comparison adults to inhibit a reflexive saccade towards the sudden appearance of a stimulus in the periphery. However, SI task performance showed that the ADHD group did not differ significantly from the comparison group on a measure of automatic inhibitory control. These findings suggest a dissociation between automatic and intentional inhibitory deficits in adults with ADHD. PMID:21058752
Tuning of automatic exposure control strength in lumbar spine CT.
D'Hondt, A; Cornil, A; Bohy, P; De Maertelaer, V; Gevenois, P A; Tack, D
2014-05-01
To investigate the impact of tuning the automatic exposure control (AEC) strength curve (specific to Care Dose 4D®; Siemens Healthcare, Forchheim, Germany) from "average" to "strong" on image quality, radiation dose and operator dependency during lumbar spine CT examinations. Two hospitals (H1, H2), both using the same scanners, were considered for two time periods (P1 and P2). During P1, the AEC curve was "average" and radiographers had to select one of two protocols according to the body mass index (BMI): "standard" if BMI <30.0 kg m(-2) (120 kV-330 mAs) or "large" if BMI >30.0 kg m(-2) (140 kV-280 mAs). During P2, the AEC curve was changed to "strong", and all acquisitions were obtained with one protocol (120 kV and 270 mAs). Image quality was scored and patients' diameters calculated for both periods. 497 examinations were analysed. There was no significant difference in mean diameters according to hospitals and periods (p > 0.801) and in quality scores between periods (p > 0.172). There was a significant difference between hospitals regarding how often the "large" protocol was assigned [13 (10%)/132 patients in H1 vs 37 (28%)/133 in H2] (p < 0.001). During P1, volume CT dose index (CTDIvol) was higher in H2 (+13%; p = 0.050). In both hospitals, CTDIvol was reduced between periods (-19.2% in H1 and -29.4% in H2; p < 0.001). An operator dependency in protocol selection, unexplained by patient diameters or highlighted by image quality scores, has been observed. Tuning the AEC curve from average to strong enables suppression of the operator dependency in protocol selection and related dose increase, while preserving image quality. CT acquisition protocols based on weight are responsible for biases in protocol selection. Using an appropriate AEC strength curve reduces the number of protocols to one. Operator dependency of protocol selection is thereby eliminated.
Code of Federal Regulations, 2010 CFR
2010-10-01
... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and... controlled, of each train operating in automatic train stop, train control, or cab signal territory shall be..., train control or cab signal territory; equipped. 236.566 Section 236.566 Transportation Other...
Code of Federal Regulations, 2011 CFR
2011-10-01
... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and... controlled, of each train operating in automatic train stop, train control, or cab signal territory shall be..., train control or cab signal territory; equipped. 236.566 Section 236.566 Transportation Other...
The Associate Principal Astronomer for AI Management of Automatic Telescopes
NASA Technical Reports Server (NTRS)
Henry, Gregory W.
1998-01-01
This research program in scheduling and management of automatic telescopes had the following objectives: 1. To field test the 1993 Automatic Telescope Instruction Set (ATIS93) programming language, which was specifically developed to allow real-time control of an automatic telescope via an artificial intelligence scheduler running on a remote computer. 2. To develop and test the procedures for two-way communication between a telescope controller and remote scheduler via the Internet. 3. To test various concepts in Al scheduling being developed at NASA Ames Research Center on an automatic telescope operated by Tennessee State University at the Fairborn Observatory site in southern Arizona. and 4. To develop a prototype software package, dubbed the Associate Principal Astronomer, for the efficient scheduling and management of automatic telescopes.
NASA Astrophysics Data System (ADS)
Widyaningrum, E.; Gorte, B. G. H.
2017-05-01
LiDAR data acquisition is recognized as one of the fastest solutions to provide basis data for large-scale topographical base maps worldwide. Automatic LiDAR processing is believed one possible scheme to accelerate the large-scale topographic base map provision by the Geospatial Information Agency in Indonesia. As a progressive advanced technology, Geographic Information System (GIS) open possibilities to deal with geospatial data automatic processing and analyses. Considering further needs of spatial data sharing and integration, the one stop processing of LiDAR data in a GIS environment is considered a powerful and efficient approach for the base map provision. The quality of the automated topographic base map is assessed and analysed based on its completeness, correctness, quality, and the confusion matrix.
NASA Technical Reports Server (NTRS)
Halyo, N.
1979-01-01
The development of a digital automatic control law for a small jet transport to perform a steep final approach in automatic landings is reported along with the development of a steady-state Kalman filter used to provide smooth estimates to the control law. The control law performs the functions of localizer and glides capture, localizer and glideslope track, decrab, and place. The control law uses the microwave landing system position data, and aircraft body-mounted accelerators, attitude and attitude rate information. The results obtained from a digital simulation of the aircraft dynamics, wind conditions, and sensor noises using the control law and filter developed are described.
NASA Technical Reports Server (NTRS)
Litt, Jonathan; Liu, Yuan; Sowers, T. Shane; Owen, A. Karl; Guo, Ten-Huei
2014-01-01
This paper describes a model-predictive automatic recovery system for aircraft on the verge of a loss-of-control situation. The system determines when it must intervene to prevent an imminent accident, resulting from a poor approach. It estimates the altitude loss that would result from a go-around maneuver at the current flight condition. If the loss is projected to violate a minimum altitude threshold, the maneuver is automatically triggered. The system deactivates to allow landing once several criteria are met. Piloted flight simulator evaluation showed the system to provide effective envelope protection during extremely unsafe landing attempts. The results demonstrate how flight and propulsion control can be integrated to recover control of the vehicle automatically and prevent a potential catastrophe.
Precise nanoliter fluid handling system with integrated high-speed flow sensor.
Haber, Carsten; Boillat, Marc; van der Schoot, Bart
2005-04-01
A system for accurate low-volume delivery of liquids in the micro- to nanoliter range makes use of an integrated miniature flow sensor as part of an intelligent feedback control loop driving a micro-solenoid valve. The flow sensor is hydraulically connected with the pressurized system liquid in the dispensing channel and located downstream from the pressure source, above the solenoid valve. The sensor operates in a differential mode and responds in real-time to the internal flow-pulse resulting from the brief opening interval of the solenoid valve leading to a rapid ejection of a fluid droplet. The integral of the flow-pulse delivered by the sensor is directly proportional to the volume of the ejected droplet from the nozzle. The quantitative information is utilized to provide active control of the effectively dispensed or aspirated volume by adjusting the solenoid valve accordingly. This process significantly enhances the precision of the fluid delivery. The system furthermore compensates automatically for any changes in the viscosity of the dispensed liquid. The data delivered by the flow sensor can be saved and backtracked in order to confirm and validate the aspiration and dispensing process in its entirety. The collected dispense information can be used for quality control assessments and automatically be made part of an electronic record.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-11
... the flap control unit (FCU). This AD was prompted by a report of automatic retraction of the leading... takeoff. We are issuing this AD to prevent automatic retraction of the leading edge flaps during takeoff... automatic retraction of the leading edge flaps due to indications transmitted to the flap control unit (FCU...
USSR Report, Kommunist, No. 13, September 1986.
1987-01-07
all-union) program for specialization of NPO and industrial enterprises and their scientific research institutes and design bureaus could play a major...machine tools with numerical programming (ChPU), processing centers, automatic machines and groups of automatic machines controlled by computers, and...automatic lines, computer- controlled groups of equipment, comprehensively automated shops and sections) is the most important feature of high technical
Electronic circuit provides automatic level control for liquid nitrogen traps
NASA Technical Reports Server (NTRS)
Turvy, R. R.
1968-01-01
Electronic circuit, based on the principle of increased thermistor resistance corresponding to decreases in temperature provides an automatic level control for liquid nitrogen cold traps. The electronically controlled apparatus is practically service-free, requiring only occasional reliability checks.
Control Law for Automatic Landing Using Fuzzy-Logic Control
NASA Astrophysics Data System (ADS)
Kato, Akio; Inagaki, Yoshiki
The effectiveness of a fuzzy-logic control law for automatically landing an aircraft that handles both the control to lead an aircraft from horizontal flight at an altitude of 500 meters to flight along the glide-path course near the runway, as well as the control to direct the aircraft to land smoothly on a runway, was investigated. The control law for the automatic landing was designed to match the design goals of directing an aircraft from horizontal flight to flight along a glide-path course quickly and smoothly, and for landing smoothly on a runway. The design of the control law and evaluation of the control performance were performed considering the ground effect at landing. As a result, it was confirmed that the design goals were achieved. Even if the characteristics of the aircraft change greatly, the proposed control law is able to maintain the control performance. Moreover, it was confirmed to be able to land an aircraft safely during air turbulence. The present paper indicates that fuzzy-logic control is an effective and flexible method when applied to the control law for automatic landing, and the design method of the control law using fuzzy-logic control was obtained.
Control Law for Automatic Landing Using Fuzzy Logic Control
NASA Astrophysics Data System (ADS)
Kato, Akio; Inagaki, Yoshiki
The effectiveness of fuzzy logic control law for automatic landing of aircraft, which cover both of control to lead aircraft from level flight at an altitude of 500m to the flight on the glide-path course near the runway and control for the aircraft to land smoothly on a runway, was studied. The control law of the automatic landing was designed to match the design goals of leading from the horizontal flight to the flight on the glide-path course quickly and smoothly and of landing smoothly on a runway. Because there is the ground effect at landing, design of control law and evaluation of control performance were done in consideration of the ground effect. As a result, it was confirmed that the design objective was achieved. Even if the characteristics of the plant changes greatly, this control law was able to maintain the control performance. Moreover, it was confirmed to be able to land safely when there was air turbulence. This paper shows that fuzzy logic control is an effective and flexible method when applied to control law for automatic landing and the design method of control law using fuzzy logic control was obtained.
A VxD-based automatic blending system using multithreaded programming.
Wang, L; Jiang, X; Chen, Y; Tan, K C
2004-01-01
This paper discusses the object-oriented software design for an automatic blending system. By combining the advantages of a programmable logic controller (PLC) and an industrial control PC (ICPC), an automatic blending control system is developed for a chemical plant. The system structure and multithread-based communication approach are first presented in this paper. The overall software design issues, such as system requirements and functionalities, are then discussed in detail. Furthermore, by replacing the conventional dynamic link library (DLL) with virtual X device drivers (VxD's), a practical and cost-effective solution is provided to improve the robustness of the Windows platform-based automatic blending system in small- and medium-sized plants.
46 CFR 61.30-20 - Automatic control and safety tests.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Automatic control and safety tests. 61.30-20 Section 61.30-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC... and safety tests. Operational tests and checks of all safety and limit controls, combustion controls...
46 CFR 61.30-20 - Automatic control and safety tests.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Automatic control and safety tests. 61.30-20 Section 61.30-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC... and safety tests. Operational tests and checks of all safety and limit controls, combustion controls...
46 CFR 61.30-20 - Automatic control and safety tests.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Automatic control and safety tests. 61.30-20 Section 61.30-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC... and safety tests. Operational tests and checks of all safety and limit controls, combustion controls...
Code of Federal Regulations, 2011 CFR
2011-10-01
... INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards... automatic cab signal system shall be arranged so that cab signals will be continuously controlled in...
NASA Astrophysics Data System (ADS)
Umam, F.; Budiarto, H.
2018-01-01
Shrimp farming becomes the main commodity of society in Madura Island East Java Indonesia. Because of Madura island has a very extreme weather, farmers have difficulty in keeping the balance of pond water. As a consequence of this condition, there are some farmers experienced losses. In this study an adaptive control system was developed using ANFIS method to control pH balance (7.5-8.5), Temperature (25-31°C), water level (70-120 cm) and Dissolved Oxygen (4-7,5 ppm). Each parameter (pH, temperature, level and DO) is controlled separately but can work together. The output of the control system is in the form of pump activation which provides the antidote to the imbalance that occurs in pond water. The system is built with two modes at once, which are automatic mode and manual mode. The manual control interface based on android which is easy to use.
Control voltage and power fluctuations when connecting wind farms
NASA Astrophysics Data System (ADS)
Berinde, Ioan; Bǎlan, Horia; Oros Pop, Teodora Susana
2015-12-01
Voltage, frequency, active power and reactive power are very important parameters in terms of power quality. These parameters are followed when connecting any power plant, the more the connection of wind farms. Connecting wind farms to the electricity system must not cause interference outside the limits set by regulations. Modern solutions for fast and automatic voltage control and power fluctuations using electronic control systems of reactive power flows. FACTS (Flexible Alternating Current Transmision System) systems, established on the basis of power electronic circuits ensure control of electrical status quantities to achieve the necessary transfer of power to the power grid. FACTS devices can quickly control parameters and sizes of state power lines, such as impedance line voltages and phase angles of the voltages of the two ends of the line. Their use can lead to improvement in power system operation by increasing the transmission capacity of power lines, power flow control lines, improved static and transient stability reserve.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, W; Wu, Q; Yuan, L
Purpose: To improve the robustness of a knowledge based automatic lung IMRT planning method and to further validate the reliability of this algorithm by utilizing for the planning of clinical cases with non-coplanar beams. Methods: A lung IMRT planning method which automatically determines both plan optimization objectives and beam configurations with non-coplanar beams has been reported previously. A beam efficiency index map is constructed to guide beam angle selection in this algorithm. This index takes into account both the dose contributions from individual beams and the combined effect of multiple beams which is represented by a beam separation score. Wemore » studied the effect of this beam separation score on plan quality and determined the optimal weight for this score.14 clinical plans were re-planned with the knowledge-based algorithm. Significant dosimetric metrics for the PTV and OARs in the automatic plans are compared with those in the clinical plans by the two-sample t-test. In addition, a composite dosimetric quality index was defined to obtain the relationship between the plan quality and the beam separation score. Results: On average, we observed more than 15% reduction on conformity index and homogeneity index for PTV and V{sub 40}, V{sub 60} for heart while an 8% and 3% increase on V{sub 5}, V{sub 20} for lungs, respectively. The variation curve of the composite index as a function of angle spread score shows that 0.6 is the best value for the weight of the beam separation score. Conclusion: Optimal value for beam angle spread score in automatic lung IMRT planning is obtained. With this value, model can result in statistically the “best” achievable plans. This method can potentially improve the quality and planning efficiency for IMRT plans with no-coplanar angles.« less
Klapper, André; Ramsey, Richard; Wigboldus, Daniël; Cross, Emily S
2014-11-01
Humans automatically imitate other people's actions during social interactions, building rapport and social closeness in the process. Although the behavioral consequences and neural correlates of imitation have been studied extensively, little is known about the neural mechanisms that control imitative tendencies. For example, the degree to which an agent is perceived as human-like influences automatic imitation, but it is not known how perception of animacy influences brain circuits that control imitation. In the current fMRI study, we examined how the perception and belief of animacy influence the control of automatic imitation. Using an imitation-inhibition paradigm that involves suppressing the tendency to imitate an observed action, we manipulated both bottom-up (visual input) and top-down (belief) cues to animacy. Results show divergent patterns of behavioral and neural responses. Behavioral analyses show that automatic imitation is equivalent when one or both cues to animacy are present but reduces when both are absent. By contrast, right TPJ showed sensitivity to the presence of both animacy cues. Thus, we demonstrate that right TPJ is biologically tuned to control imitative tendencies when the observed agent both looks like and is believed to be human. The results suggest that right TPJ may be involved in a specialized capacity to control automatic imitation of human agents, rather than a universal process of conflict management, which would be more consistent with generalist theories of imitative control. Evidence for specialized neural circuitry that "controls" imitation offers new insight into developmental disorders that involve atypical processing of social information, such as autism spectrum disorders.
Ozhinsky, Eugene; Vigneron, Daniel B; Nelson, Sarah J
2011-04-01
To develop a technique for optimizing coverage of brain 3D (1) H magnetic resonance spectroscopic imaging (MRSI) by automatic placement of outer-volume suppression (OVS) saturation bands (sat bands) and to compare the performance for point-resolved spectroscopic sequence (PRESS) MRSI protocols with manual and automatic placement of sat bands. The automated OVS procedure includes the acquisition of anatomic images from the head, obtaining brain and lipid tissue maps, calculating optimal sat band placement, and then using those optimized parameters during the MRSI acquisition. The data were analyzed to quantify brain coverage volume and data quality. 3D PRESS MRSI data were acquired from three healthy volunteers and 29 patients using protocols that included either manual or automatic sat band placement. On average, the automatic sat band placement allowed the acquisition of PRESS MRSI data from 2.7 times larger brain volumes than the conventional method while maintaining data quality. The technique developed helps solve two of the most significant problems with brain PRESS MRSI acquisitions: limited brain coverage and difficulty in prescription. This new method will facilitate routine clinical brain 3D MRSI exams and will be important for performing serial evaluation of response to therapy in patients with brain tumors and other neurological diseases. Copyright © 2011 Wiley-Liss, Inc.
NASA Technical Reports Server (NTRS)
Wolf, Jared J.
1977-01-01
The following research was discussed: (1) speech signal processing; (2) automatic speech recognition; (3) continuous speech understanding; (4) speaker recognition; (5) speech compression; (6) subjective and objective evaluation of speech communication system; (7) measurement of the intelligibility and quality of speech when degraded by noise or other masking stimuli; (8) speech synthesis; (9) instructional aids for second-language learning and for training of the deaf; and (10) investigation of speech correlates of psychological stress. Experimental psychology, control systems, and human factors engineering, which are often relevant to the proper design and operation of speech systems are described.
ERIC Educational Resources Information Center
Jonach, Rafael; Ebner, Martin; Grigoriadis, Ypatios
2015-01-01
Lectures of courses at universities are increasingly being recorded and offered through various distribution channels to support students' learning activities. This research work aims to create an automatic system for producing and distributing high quality lecture recordings. Opencast Matterhorn is an open source platform for automated video…
The role of automatic control in future interplanetary spaceflight
NASA Technical Reports Server (NTRS)
Scull, J. R.; Moore, J. W.
1976-01-01
The paper reviews the guidance and automatic control techniques used in previous U.S. and Soviet lunar and planetary exploration spacecraft, and examines the objectives and requirements of potential future interplanetary missions from the viewpoint of their further demands on automatic control technology. These missions include the Venus orbital imaging radar mission, the Pioneer Mars penetrator mission, the Mars surface sample return mission, Pioneer Saturn/Uranus/Titan probe missions, the Mariner Jupiter orbiter with daughter satellite, and comet and asteroid missions.
How much image noise can be added in cardiac x-ray imaging without loss in perceived image quality?
NASA Astrophysics Data System (ADS)
Gislason-Lee, Amber J.; Kumcu, Asli; Kengyelics, Stephen M.; Rhodes, Laura A.; Davies, Andrew G.
2015-03-01
Dynamic X-ray imaging systems are used for interventional cardiac procedures to treat coronary heart disease. X-ray settings are controlled automatically by specially-designed X-ray dose control mechanisms whose role is to ensure an adequate level of image quality is maintained with an acceptable radiation dose to the patient. Current commonplace dose control designs quantify image quality by performing a simple technical measurement directly from the image. However, the utility of cardiac X-ray images is in their interpretation by a cardiologist during an interventional procedure, rather than in a technical measurement. With the long term goal of devising a clinically-relevant image quality metric for an intelligent dose control system, we aim to investigate the relationship of image noise with clinical professionals' perception of dynamic image sequences. Computer-generated noise was added, in incremental amounts, to angiograms of five different patients selected to represent the range of adult cardiac patient sizes. A two alternative forced choice staircase experiment was used to determine the amount of noise which can be added to a patient image sequences without changing image quality as perceived by clinical professionals. Twenty-five viewing sessions (five for each patient) were completed by thirteen observers. Results demonstrated scope to increase the noise of cardiac X-ray images by up to 21% +/- 8% before it is noticeable by clinical professionals. This indicates a potential for 21% radiation dose reduction since X-ray image noise and radiation dose are directly related; this would be beneficial to both patients and personnel.
NASA Technical Reports Server (NTRS)
Smith, G. A.; Meyer, G.
1980-01-01
The results of a simulation study of an alternative design concept for an automatic landing control system are presented. The alternative design concept for an automatic landing control system is described. The design concept is the total aircraft flight control system (TAFCOS). TAFCOS is an open loop, feed forward system that commands the proper instantaneous thrust, angle of attack, and roll angle to achieve the forces required to follow the desired trajector. These dynamic trim conditions are determined by an inversion of the aircraft nonlinear force characteristics. The concept was applied to an A-7E aircraft approaching an aircraft carrier. The implementation details with an airborne digital computer are discussed. The automatic carrier landing situation is described. The simulation results are presented for a carrier approach with atmospheric disturbances, an approach with no disturbances, and for tailwind and headwind gusts.
Koch, Saskia B J; Klumpers, Floris; Zhang, Wei; Hashemi, Mahur M; Kaldewaij, Reinoud; van Ast, Vanessa A; Smit, Annika S; Roelofs, Karin
2017-01-01
Background : Control over automatic tendencies is often compromised in challenging situations when people fall back on automatic defensive reactions, such as freeze - fight - flight responses. Stress-induced lack of control over automatic defensive responses constitutes a problem endemic to high-risk professions, such as the police. Difficulties controlling automatic defensive responses may not only impair split-second decisions under threat, but also increase the risk for and persistence of posttraumatic stress disorder (PTSD) symptoms. However, the significance of these automatic defensive responses in the development and maintenance of trauma-related symptoms remains unclear due to a shortage of large-scale prospective studies. Objective : The 'Police-in-Action' study is conducted to investigate the role of automatic defensive responses in the development and maintenance of PTSD symptomatology after trauma exposure. Methods : In this prospective study, 340 police recruits from the Dutch Police Academy are tested before (wave 1; pre-exposure) and after (wave 2; post-exposure) their first emergency aid experiences as police officers. The two waves of data assessment are separated by approximately 15 months. To control for unspecific time effects, a well-matched control group of civilians ( n = 85) is also tested twice, approximately 15 months apart, but without being frequently exposed to potentially traumatic events. Main outcomes are associations between (changes in) behavioural, psychophysiological, endocrine and neural markers of automatic defensive responses and development of trauma-related symptoms after trauma exposure in police recruits. Discussion : This prospective study in a large group of primary responders enables us to distinguish predisposing from acquired neurobiological abnormalities in automatic defensive responses, associated with the development of trauma-related symptoms. Identifying neurobiological correlates of (vulnerability for) trauma-related psychopathology may greatly improve screening for individuals at risk for developing PTSD symptomatology and offer valuable targets for (early preventive) interventions for PTSD.
49 CFR 236.826 - System, automatic train stop.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false System, automatic train stop. 236.826 Section 236..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.826 System, automatic train stop. A system so arranged that its operation will automatically...
49 CFR 236.826 - System, automatic train stop.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false System, automatic train stop. 236.826 Section 236..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.826 System, automatic train stop. A system so arranged that its operation will automatically...
49 CFR 236.503 - Automatic brake application; initiation when predetermined rate of speed exceeded.
Code of Federal Regulations, 2011 CFR
2011-10-01
... predetermined rate of speed exceeded. 236.503 Section 236.503 Transportation Other Regulations Relating to... § 236.503 Automatic brake application; initiation when predetermined rate of speed exceeded. An automatic train control system shall operate to initiate an automatic brake application when the speed of...
49 CFR 236.503 - Automatic brake application; initiation when predetermined rate of speed exceeded.
Code of Federal Regulations, 2010 CFR
2010-10-01
... predetermined rate of speed exceeded. 236.503 Section 236.503 Transportation Other Regulations Relating to... § 236.503 Automatic brake application; initiation when predetermined rate of speed exceeded. An automatic train control system shall operate to initiate an automatic brake application when the speed of...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-05
... exposure control, image processing and reconstruction programs, patient and equipment supports, component..., acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and... may include was revised by adding automatic exposure control, image processing and reconstruction...
Modern Control Aspects of Automatically Steered Vehicles
DOT National Transportation Integrated Search
1971-12-01
In the study of automatically steered rubber tired vehicles, little emphasis in the past has been placed on the steering control laws. The report examines the control law problem from the state variable point of view and it is shown that, except for ...
Dodge, Kenneth A
2008-01-01
Berkowitz (this issue) makes a cogent case for his cognitive neo-associationist (CNA) model that some aggressive behaviors occur automatically, emotionally, and through conditioned association with other stimuli. He also proposes that they can occur without "processing," that is, without meaning. He contrasts his position with that of social information processing (SIP) models, which he casts as positing only controlled processing mechanisms for aggressive behavior. However, both CNA and SIP models posit automatic as well as controlled processes in aggressive behavior. Most aggressive behaviors occur through automatic processes, which are nonetheless rule governed. SIP models differ from the CNA model in asserting the essential role of meaning (often through nonconscious, automatic, and emotional processes) in mediating the link between a stimulus and an angry aggressive behavioral response. Copyright 2008 Wiley-Liss, Inc.
GenePRIMP: A Gene Prediction Improvement Pipeline For Prokaryotic Genomes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kyrpides, Nikos C.; Ivanova, Natalia N.; Pati, Amrita
2010-07-08
GenePRIMP (Gene Prediction Improvement Pipeline, Http://geneprimp.jgi-psf.org), a computational process that performs evidence-based evaluation of gene models in prokaryotic genomes and reports anomalies including inconsistent start sites, missing genes, and split genes. We show that manual curation of gene models using the anomaly reports generated by GenePRIMP improves their quality and demonstrate the applicability of GenePRIMP in improving finishing quality and comparing different genome sequencing and annotation technologies. Keywords in context: Gene model, Quality Control, Translation start sites, Automatic correction. Hardware requirements; PC, MAC; Operating System: UNIX/LINUX; Compiler/Version: Perl 5.8.5 or higher; Special requirements: NCBI Blast and nr installation; File Types:more » Source Code, Executable module(s), Sample problem input data; installation instructions other; programmer documentation. Location/transmission: http://geneprimp.jgi-psf.org/gp.tar.gz« less
Random Forest Application for NEXRAD Radar Data Quality Control
NASA Astrophysics Data System (ADS)
Keem, M.; Seo, B. C.; Krajewski, W. F.
2017-12-01
Identification and elimination of non-meteorological radar echoes (e.g., returns from ground, wind turbines, and biological targets) are the basic data quality control steps before radar data use in quantitative applications (e.g., precipitation estimation). Although WSR-88Ds' recent upgrade to dual-polarization has enhanced this quality control and echo classification, there are still challenges to detect some non-meteorological echoes that show precipitation-like characteristics (e.g., wind turbine or anomalous propagation clutter embedded in rain). With this in mind, a new quality control method using Random Forest is proposed in this study. This classification algorithm is known to produce reliable results with less uncertainty. The method introduces randomness into sampling and feature selections and integrates consequent multiple decision trees. The multidimensional structure of the trees can characterize the statistical interactions of involved multiple features in complex situations. The authors explore the performance of Random Forest method for NEXRAD radar data quality control. Training datasets are selected using several clear cases of precipitation and non-precipitation (but with some non-meteorological echoes). The model is structured using available candidate features (from the NEXRAD data) such as horizontal reflectivity, differential reflectivity, differential phase shift, copolar correlation coefficient, and their horizontal textures (e.g., local standard deviation). The influence of each feature on classification results are quantified by variable importance measures that are automatically estimated by the Random Forest algorithm. Therefore, the number and types of features in the final forest can be examined based on the classification accuracy. The authors demonstrate the capability of the proposed approach using several cases ranging from distinct to complex rain/no-rain events and compare the performance with the existing algorithms (e.g., MRMS). They also discuss operational feasibility based on the observed strength and weakness of the method.
2013-01-01
Background Most of the institutional and research information in the biomedical domain is available in the form of English text. Even in countries where English is an official language, such as the United States, language can be a barrier for accessing biomedical information for non-native speakers. Recent progress in machine translation suggests that this technique could help make English texts accessible to speakers of other languages. However, the lack of adequate specialized corpora needed to train statistical models currently limits the quality of automatic translations in the biomedical domain. Results We show how a large-sized parallel corpus can automatically be obtained for the biomedical domain, using the MEDLINE database. The corpus generated in this work comprises article titles obtained from MEDLINE and abstract text automatically retrieved from journal websites, which substantially extends the corpora used in previous work. After assessing the quality of the corpus for two language pairs (English/French and English/Spanish) we use the Moses package to train a statistical machine translation model that outperforms previous models for automatic translation of biomedical text. Conclusions We have built translation data sets in the biomedical domain that can easily be extended to other languages available in MEDLINE. These sets can successfully be applied to train statistical machine translation models. While further progress should be made by incorporating out-of-domain corpora and domain-specific lexicons, we believe that this work improves the automatic translation of biomedical texts. PMID:23631733
Stock, Ann-Kathrin; Steenbergen, Laura; Colzato, Lorenza; Beste, Christian
2016-12-01
Cognitive control is adaptive in the sense that it inhibits automatic processes to optimize goal-directed behavior, but high levels of control may also have detrimental effects in case they suppress beneficial automatisms. Until now, the system neurophysiological mechanisms and functional neuroanatomy underlying these adverse effects of cognitive control have remained elusive. This question was examined by analyzing the automatic exploitation of a beneficial implicit predictive feature under conditions of high versus low cognitive control demands, combining event-related potentials (ERPs) and source localization. It was found that cognitive control prohibits the beneficial automatic exploitation of additional implicit information when task demands are high. Bottom-up perceptual and attentional selection processes (P1 and N1 ERPs) are not modulated by this, but the automatic exploitation of beneficial predictive information in case of low cognitive control demands was associated with larger response-locked P3 amplitudes and stronger activation of the right inferior frontal gyrus (rIFG, BA47). This suggests that the rIFG plays a key role in the detection of relevant task cues, the exploitation of alternative task sets, and the automatic (bottom-up) implementation and reprogramming of action plans. Moreover, N450 amplitudes were larger under high cognitive control demands, which was associated with activity differences in the right medial frontal gyrus (BA9). This most likely reflects a stronger exploitation of explicit task sets which hinders the exploration of the implicit beneficial information in case of high cognitive control demands. Hum Brain Mapp 37:4511-4522, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
DOT National Transportation Integrated Search
1971-06-01
ATO (automatic train operation) and ATC (automatic train control) systems are evaluated relative to available technology and cost-benefit. The technological evaluation shows that suitable mathematical models of the dynamics of long trains are require...
Xu, Weichen; Jimenez, Rod Brian; Mowery, Rachel; Luo, Haibin; Cao, Mingyan; Agarwal, Nitin; Ramos, Irina; Wang, Xiangyang; Wang, Jihong
2017-10-01
During manufacturing and storage process, therapeutic proteins are subject to various post-translational modifications (PTMs), such as isomerization, deamidation, oxidation, disulfide bond modifications and glycosylation. Certain PTMs may affect bioactivity, stability or pharmacokinetics and pharmacodynamics profile and are therefore classified as potential critical quality attributes (pCQAs). Identifying, monitoring and controlling these PTMs are usually key elements of the Quality by Design (QbD) approach. Traditionally, multiple analytical methods are utilized for these purposes, which is time consuming and costly. In recent years, multi-attribute monitoring methods have been developed in the biopharmaceutical industry. However, these methods combine high-end mass spectrometry with complicated data analysis software, which could pose difficulty when implementing in a quality control (QC) environment. Here we report a multi-attribute method (MAM) using a Quadrupole Dalton (QDa) mass detector to selectively monitor and quantitate PTMs in a therapeutic monoclonal antibody. The result output from the QDa-based MAM is straightforward and automatic. Evaluation results indicate this method provides comparable results to the traditional assays. To ensure future application in the QC environment, this method was qualified according to the International Conference on Harmonization (ICH) guideline and applied in the characterization of drug substance and stability samples. The QDa-based MAM is shown to be an extremely useful tool for product and process characterization studies that facilitates facile understanding of process impact on multiple quality attributes, while being QC friendly and cost-effective.
NASA Technical Reports Server (NTRS)
Navard, Sharon E.
1989-01-01
In recent years there has been a push within NASA to use statistical techniques to improve the quality of production. Two areas where statistics are used are in establishing product and process quality control of flight hardware and in evaluating the uncertainty of calibration of instruments. The Flight Systems Quality Engineering branch is responsible for developing and assuring the quality of all flight hardware; the statistical process control methods employed are reviewed and evaluated. The Measurement Standards and Calibration Laboratory performs the calibration of all instruments used on-site at JSC as well as those used by all off-site contractors. These calibrations must be performed in such a way as to be traceable to national standards maintained by the National Institute of Standards and Technology, and they must meet a four-to-one ratio of the instrument specifications to calibrating standard uncertainty. In some instances this ratio is not met, and in these cases it is desirable to compute the exact uncertainty of the calibration and determine ways of reducing it. A particular example where this problem is encountered is with a machine which does automatic calibrations of force. The process of force calibration using the United Force Machine is described in detail. The sources of error are identified and quantified when possible. Suggestions for improvement are made.
Stefanidis, Dimitrios; Scerbo, Mark W; Montero, Paul N; Acker, Christina E; Smith, Warren D
2012-01-01
We hypothesized that novices will perform better in the operating room after simulator training to automaticity compared with traditional proficiency based training (current standard training paradigm). Simulator-acquired skill translates to the operating room, but the skill transfer is incomplete. Secondary task metrics reflect the ability of trainees to multitask (automaticity) and may improve performance assessment on simulators and skill transfer by indicating when learning is complete. Novices (N = 30) were enrolled in an IRB-approved, blinded, randomized, controlled trial. Participants were randomized into an intervention (n = 20) and a control (n = 10) group. The intervention group practiced on the FLS suturing task until they achieved expert levels of time and errors (proficiency), were tested on a live porcine fundoplication model, continued simulator training until they achieved expert levels on a visual spatial secondary task (automaticity) and were retested on the operating room (OR) model. The control group participated only during testing sessions. Performance scores were compared within and between groups during testing sessions. : Intervention group participants achieved proficiency after 54 ± 14 and automaticity after additional 109 ± 57 repetitions. Participants achieved better scores in the OR after automaticity training [345 (range, 0-537)] compared with after proficiency-based training [220 (range, 0-452; P < 0.001]. Simulator training to automaticity takes more time but is superior to proficiency-based training, as it leads to improved skill acquisition and transfer. Secondary task metrics that reflect trainee automaticity should be implemented during simulator training to improve learning and skill transfer.
Ahlers, C; Simader, C; Geitzenauer, W; Stock, G; Stetson, P; Dastmalchi, S; Schmidt-Erfurth, U
2008-02-01
A limited number of scans compromise conventional optical coherence tomography (OCT) to track chorioretinal disease in its full extension. Failures in edge-detection algorithms falsify the results of retinal mapping even further. High-definition-OCT (HD-OCT) is based on raster scanning and was used to visualise the localisation and volume of intra- and sub-pigment-epithelial (RPE) changes in fibrovascular pigment epithelial detachments (fPED). Two different scanning patterns were evaluated. 22 eyes with fPED were imaged using a frequency-domain, high-speed prototype of the Cirrus HD-OCT. The axial resolution was 6 mum, and the scanning speed was 25 kA scans/s. Two different scanning patterns covering an area of 6 x 6 mm in the macular retina were compared. Three-dimensional topographic reconstructions and volume calculations were performed using MATLAB-based automatic segmentation software. Detailed information about layer-specific distribution of fluid accumulation and volumetric measurements can be obtained for retinal- and sub-RPE volumes. Both raster scans show a high correlation (p<0.01; R2>0.89) of measured values, that is PED volume/area, retinal volume and mean retinal thickness. Quality control of the automatic segmentation revealed reasonable results in over 90% of the examinations. Automatic segmentation allows for detailed quantitative and topographic analysis of the RPE and the overlying retina. In fPED, the 128 x 512 scanning-pattern shows mild advantages when compared with the 256 x 256 scan. Together with the ability for automatic segmentation, HD-OCT clearly improves the clinical monitoring of chorioretinal disease by adding relevant new parameters. HD-OCT is likely capable of enhancing the understanding of pathophysiology and benefits of treatment for current anti-CNV strategies in future.
ActiveSeismoPick3D - automatic first arrival determination for large active seismic arrays
NASA Astrophysics Data System (ADS)
Paffrath, Marcel; Küperkoch, Ludger; Wehling-Benatelli, Sebastian; Friederich, Wolfgang
2016-04-01
We developed a tool for automatic determination of first arrivals in active seismic data based on an approach, that utilises higher order statistics (HOS) and the Akaike information criterion (AIC), commonly used in seismology, but not in active seismics. Automatic picking is highly desirable in active seismics as the number of data provided by large seismic arrays rapidly exceeds of what an analyst can evaluate in a reasonable amount of time. To bring the functionality of automatic phase picking into the context of active data, the software package ActiveSeismoPick3D was developed in Python. It uses a modified algorithm for the determination of first arrivals which searches for the HOS maximum in unfiltered data. Additionally, it offers tools for manual quality control and postprocessing, e.g. various visualisation and repicking functionalities. For flexibility, the tool also includes methods for the preparation of geometry information of large seismic arrays and improved interfaces to the Fast Marching Tomography Package (FMTOMO), which can be used for the prediction of travel times and inversion for subsurface properties. Output files are generated in the VTK format, allowing the 3D visualization of e.g. the inversion results. As a test case, a data set consisting of 9216 traces from 64 shots was gathered, recorded at 144 receivers deployed in a regular 2D array of a size of 100 x 100 m. ActiveSeismoPick3D automatically checks the determined first arrivals by a dynamic signal to noise ratio threshold. From the data a 3D model of the subsurface was generated using the export functionality of the package and FMTOMO.
Code of Federal Regulations, 2011 CFR
2011-10-01
... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.747 Forestall. As applied to an automatic train stop or train control device, to prevent an automatic brake application by operation of an acknowledging device or by manual control of the speed of the train. ...
49 CFR 236.507 - Brake application; full service.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.507 Brake application; full service. The automatic train stop or train control apparatus shall, when operated, cause a full service...
49 CFR 236.507 - Brake application; full service.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.507 Brake application; full service. The automatic train stop or train control apparatus shall, when operated, cause a full service...
Code of Federal Regulations, 2010 CFR
2010-10-01
... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.747 Forestall. As applied to an automatic train stop or train control device, to prevent an automatic brake application by operation of an acknowledging device or by manual control of the speed of the train. ...
NASA Astrophysics Data System (ADS)
Evtushenko, V. F.; Myshlyaev, L. P.; Makarov, G. V.; Ivushkin, K. A.; Burkova, E. V.
2016-10-01
The structure of multi-variant physical and mathematical models of control system is offered as well as its application for adjustment of automatic control system (ACS) of production facilities on the example of coal processing plant.
A semi-automatic 2D-to-3D video conversion with adaptive key-frame selection
NASA Astrophysics Data System (ADS)
Ju, Kuanyu; Xiong, Hongkai
2014-11-01
To compensate the deficit of 3D content, 2D to 3D video conversion (2D-to-3D) has recently attracted more attention from both industrial and academic communities. The semi-automatic 2D-to-3D conversion which estimates corresponding depth of non-key-frames through key-frames is more desirable owing to its advantage of balancing labor cost and 3D effects. The location of key-frames plays a role on quality of depth propagation. This paper proposes a semi-automatic 2D-to-3D scheme with adaptive key-frame selection to keep temporal continuity more reliable and reduce the depth propagation errors caused by occlusion. The potential key-frames would be localized in terms of clustered color variation and motion intensity. The distance of key-frame interval is also taken into account to keep the accumulated propagation errors under control and guarantee minimal user interaction. Once their depth maps are aligned with user interaction, the non-key-frames depth maps would be automatically propagated by shifted bilateral filtering. Considering that depth of objects may change due to the objects motion or camera zoom in/out effect, a bi-directional depth propagation scheme is adopted where a non-key frame is interpolated from two adjacent key frames. The experimental results show that the proposed scheme has better performance than existing 2D-to-3D scheme with fixed key-frame interval.
14 CFR Appendix I to Part 25 - Installation of an Automatic Takeoff Thrust Control System (ATTCS)
Code of Federal Regulations, 2010 CFR
2010-01-01
...) This appendix specifies additional requirements for installation of an engine power control system that... crew to increase thrust or power. I25.2Definitions. (a) Automatic Takeoff Thrust Control System (ATTCS... mechanical and electrical, that sense engine failure, transmit signals, actuate fuel controls or power levers...
49 CFR 571.123 - Standard No. 123; Motorcycle controls and displays.
Code of Federal Regulations, 2010 CFR
2010-10-01
... handgrip. If a motorcycle with an automatic clutch other than a scooter is equipped with a supplemental rear brake control, the control shall be located on the left handlebar. If a scooter with an automatic... equipped with self-proportioning or antilock braking devices utilizing a single control for front and rear...
Optical Methods For Automatic Rating Of Engine Test Components
NASA Astrophysics Data System (ADS)
Pritchard, James R.; Moss, Brian C.
1989-03-01
In recent years, increasing commercial and legislative pressure on automotive engine manufacturers, including increased oil drain intervals, cleaner exhaust emissions and high specific power outputs, have led to increasing demands on lubricating oil performance. Lubricant performance is defined by bench engine tests run under closely controlled conditions. After test, engines are dismantled and the parts rated for wear and accumulation of deposit. This rating must be consistently carried out in laboratories throughout the world in order to ensure lubricant quality meeting the specified standards. To this end, rating technicians evaluate components, following closely defined procedures. This process is time consuming, inaccurate and subject to drift, requiring regular recalibration of raters by means of international rating workshops. This paper describes two instruments for automatic rating of engine parts. The first uses a laser to determine the degree of polishing of the engine cylinder bore, caused by the reciprocating action of piston. This instrument has been developed to prototype stage by the NDT Centre at Harwell under contract to Exxon Chemical, and is planned for production within the next twelve months. The second instrument uses red and green filtered light to determine the type, quality and position of deposit formed on the piston surfaces. The latter device has undergone feasibility study, but no prototype exists.
NASA Astrophysics Data System (ADS)
Moench, Ingo; Peter, Laszlo; Priem, Roland; Sturm, Volker; Noll, Reinhard
1999-09-01
In plants of the chemical, nuclear and off-shore industry, application specific high-alloyed steels are used for pipe fittings. Mixing of different steel grades can lead to corrosion with severe consequential damages. Growing quality requirements and environmental responsibilities demand a 100% material control in the production of the pipe fittings. Therefore, LIFT, an automatic inspection machine, was developed to insure against any mix of material grades. LIFT is able to identify more than 30 different steel grades. The inspection method is based on Laser-Induced Breakdown Spectrometry (LIBS). An expert system, which can be easily trained and recalibrated, was developed for the data evaluation. The result of the material inspection is transferred to an external handling system via a PLC interface. The duration of the inspection process is 2 seconds. The graphical user interface was developed with respect to the requirements of an unskilled operator. The software is based on a realtime operating system and provides a safe and reliable operation. An interface for the remote maintenance by modem enables a fast operational support. Logged data are retrieved and evaluated. This is the basis for an adaptive improvement of the configuration of LIFT with respect to changing requirements in the production line. Within the first six months of routine operation, about 50000 pipe fittings were inspected.