NASA Astrophysics Data System (ADS)
Kotenev, A. V.; Kotenev, V. I.; Kochetkov, V. V.; Elkin, D. A.
2018-01-01
For the purpose of reactive power control error reduction and decrease of the voltage sags in the electric power system caused by the asynchronous motors started the mathematical model of the load bus was developed. The model was built up of the sub-models of the following elements: a transformer, a transmission line, a synchronous and an asynchronous loads and a capacitor bank load, and represents the automatic reactive power control system taking into account electromagnetic processes of the asynchronous motors started and reactive power changing of the electric power system elements caused by the voltage fluctuation. The active power/time and reactive power/time characteristics based on the recommended procedure of the equivalent electric circuit parameters calculation were obtained. The derived automatic reactive power control system was shown to eliminate the voltage sags in the electric power system caused by the asynchronous motors started.
Control circuit maintains unity power factor of reactive load
NASA Technical Reports Server (NTRS)
Kramer, M.; Martinage, L. H.
1966-01-01
Circuit including feedback control elements automatically corrects the power factor of a reactive load. It maintains power supply efficiency where negative load reactance changes and varies by providing corrective error signals to the control windings of a power supply transformer.
NASA Astrophysics Data System (ADS)
Juromskiy, V. M.
2016-09-01
It is developed a mathematical model for an electric drive of high-speed separation device in terms of the modeling dynamic systems Simulink, MATLAB. The model is focused on the study of the automatic control systems of the power factor (Cosφ) of an actuator by compensating the reactive component of the total power by switching a capacitor bank in series with the actuator. The model is based on the methodology of the structural modeling of dynamic processes.
White, David B.
1991-01-01
An electrical safety device for use in power tools that is designed to automatically discontinue operation of the power tool upon physical contact of the tool with a concealed conductive material. A step down transformer is used to supply the operating power for a disconnect relay and a reset relay. When physical contact is made between the power tool and the conductive material, an electrical circuit through the disconnect relay is completed and the operation of the power tool is automatically interrupted. Once the contact between the tool and conductive material is broken, the power tool can be quickly and easily reactivated by a reset push button activating the reset relay. A remote reset is provided for convenience and efficiency of operation.
Digital slip frequency generator and method for determining the desired slip frequency
Klein, Frederick F.
1989-01-01
The output frequency of an electric power generator is kept constant with variable rotor speed by automatic adjustment of the excitation slip frequency. The invention features a digital slip frequency generator which provides sine and cosine waveforms from a look-up table, which are combined with real and reactive power output of the power generator.
Vehicle-to-Grid Automatic Load Sharing with Driver Preference in Micro-Grids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Yubo; Nazaripouya, Hamidreza; Chu, Chi-Cheng
Integration of Electrical Vehicles (EVs) with power grid not only brings new challenges for load management, but also opportunities for distributed storage and generation. This paper comprehensively models and analyzes distributed Vehicle-to-Grid (V2G) for automatic load sharing with driver preference. In a micro-grid with limited communications, V2G EVs need to decide load sharing based on their own power and voltage profile. A droop based controller taking into account driver preference is proposed in this paper to address the distributed control of EVs. Simulations are designed for three fundamental V2G automatic load sharing scenarios that include all system dynamics of suchmore » applications. Simulation results demonstrate that active power sharing is achieved proportionally among V2G EVs with consideration of driver preference. In additional, the results also verify the system stability and reactive power sharing analysis in system modelling, which sheds light on large scale V2G automatic load sharing in more complicated cases.« less
Control voltage and power fluctuations when connecting wind farms
NASA Astrophysics Data System (ADS)
Berinde, Ioan; Bǎlan, Horia; Oros Pop, Teodora Susana
2015-12-01
Voltage, frequency, active power and reactive power are very important parameters in terms of power quality. These parameters are followed when connecting any power plant, the more the connection of wind farms. Connecting wind farms to the electricity system must not cause interference outside the limits set by regulations. Modern solutions for fast and automatic voltage control and power fluctuations using electronic control systems of reactive power flows. FACTS (Flexible Alternating Current Transmision System) systems, established on the basis of power electronic circuits ensure control of electrical status quantities to achieve the necessary transfer of power to the power grid. FACTS devices can quickly control parameters and sizes of state power lines, such as impedance line voltages and phase angles of the voltages of the two ends of the line. Their use can lead to improvement in power system operation by increasing the transmission capacity of power lines, power flow control lines, improved static and transient stability reserve.
Control voltage and power fluctuations when connecting wind farms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berinde, Ioan, E-mail: ioan-berinde@yahoo.com; Bălan, Horia, E-mail: hbalan@mail.utcluj.ro; Oros, Teodora Susana, E-mail: teodoraoros-87@yahoo.com
2015-12-23
Voltage, frequency, active power and reactive power are very important parameters in terms of power quality. These parameters are followed when connecting any power plant, the more the connection of wind farms. Connecting wind farms to the electricity system must not cause interference outside the limits set by regulations. Modern solutions for fast and automatic voltage control and power fluctuations using electronic control systems of reactive power flows. FACTS (Flexible Alternating Current Transmision System) systems, established on the basis of power electronic circuits ensure control of electrical status quantities to achieve the necessary transfer of power to the power grid.more » FACTS devices can quickly control parameters and sizes of state power lines, such as impedance line voltages and phase angles of the voltages of the two ends of the line. Their use can lead to improvement in power system operation by increasing the transmission capacity of power lines, power flow control lines, improved static and transient stability reserve.« less
Demonstration of Essential Reliability Services by a 300-MW Solar Photovoltaic Power Plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loutan, Clyde; Klauer, Peter; Chowdhury, Sirajul
The California Independent System Operator (CAISO), First Solar, and the National Renewable Energy Laboratory (NREL) conducted a demonstration project on a large utility-scale photovoltaic (PV) power plant in California to test its ability to provide essential ancillary services to the electric grid. With increasing shares of solar- and wind-generated energy on the electric grid, traditional generation resources equipped with automatic governor control (AGC) and automatic voltage regulation controls -- specifically, fossil thermal -- are being displaced. The deployment of utility-scale, grid-friendly PV power plants that incorporate advanced capabilities to support grid stability and reliability is essential for the large-scale integrationmore » of PV generation into the electric power grid, among other technical requirements. A typical PV power plant consists of multiple power electronic inverters and can contribute to grid stability and reliability through sophisticated 'grid-friendly' controls. In this way, PV power plants can be used to mitigate the impact of variability on the grid, a role typically reserved for conventional generators. In August 2016, testing was completed on First Solar's 300-MW PV power plant, and a large amount of test data was produced and analyzed that demonstrates the ability of PV power plants to use grid-friendly controls to provide essential reliability services. These data showed how the development of advanced power controls can enable PV to become a provider of a wide range of grid services, including spinning reserves, load following, voltage support, ramping, frequency response, variability smoothing, and frequency regulation to power quality. Specifically, the tests conducted included various forms of active power control such as AGC and frequency regulation; droop response; and reactive power, voltage, and power factor controls. This project demonstrated that advanced power electronics and solar generation can be controlled to contribute to system-wide reliability. It was shown that the First Solar plant can provide essential reliability services related to different forms of active and reactive power controls, including plant participation in AGC, primary frequency control, ramp rate control, and voltage regulation. For AGC participation in particular, by comparing the PV plant testing results to the typical performance of individual conventional technologies, we showed that regulation accuracy by the PV plant is 24-30 points better than fast gas turbine technologies. The plant's ability to provide volt-ampere reactive control during periods of extremely low power generation was demonstrated as well. The project team developed a pioneering demonstration concept and test plan to show how various types of active and reactive power controls can leverage PV generation's value from being a simple variable energy resource to a resource that provides a wide range of ancillary services. With this project's approach to a holistic demonstration on an actual, large, utility-scale, operational PV power plant and dissemination of the obtained results, the team sought to close some gaps in perspectives that exist among various stakeholders in California and nationwide by providing real test data.« less
Design, Specification, and Synthesis of Aircraft Electric Power Systems Control Logic
NASA Astrophysics Data System (ADS)
Xu, Huan
Cyber-physical systems integrate computation, networking, and physical processes. Substantial research challenges exist in the design and verification of such large-scale, distributed sensing, actuation, and control systems. Rapidly improving technology and recent advances in control theory, networked systems, and computer science give us the opportunity to drastically improve our approach to integrated flow of information and cooperative behavior. Current systems rely on text-based specifications and manual design. Using new technology advances, we can create easier, more efficient, and cheaper ways of developing these control systems. This thesis will focus on design considerations for system topologies, ways to formally and automatically specify requirements, and methods to synthesize reactive control protocols, all within the context of an aircraft electric power system as a representative application area. This thesis consists of three complementary parts: synthesis, specification, and design. The first section focuses on the synthesis of central and distributed reactive controllers for an aircraft elec- tric power system. This approach incorporates methodologies from computer science and control. The resulting controllers are correct by construction with respect to system requirements, which are formulated using the specification language of linear temporal logic (LTL). The second section addresses how to formally specify requirements and introduces a domain-specific language for electric power systems. A software tool automatically converts high-level requirements into LTL and synthesizes a controller. The final sections focus on design space exploration. A design methodology is proposed that uses mixed-integer linear programming to obtain candidate topologies, which are then used to synthesize controllers. The discrete-time control logic is then verified in real-time by two methods: hardware and simulation. Finally, the problem of partial observability and dynamic state estimation is explored. Given a set placement of sensors on an electric power system, measurements from these sensors can be used in conjunction with control logic to infer the state of the system.
NASA Astrophysics Data System (ADS)
Su, Yi; Wang, Feifeng; Lu, Yufeng; Huang, Huimin; Xia, Xiaofei
2017-09-01
This paper is based on affine function equation of the grid and OPF problem, discusses the equivalent of some inequality constraints variables optimizing. Further, we propose the model of injection current and set up the constraint sensitivity index of affine characteristics. The index can be used to identify the central point voltage and effective inequality of the system automatically. And then we can know how to compensate reactive power of the corresponding generator node and control the voltage to ensure the quality of the system voltage. When checking the effective inequalities we introduce cross-solving method of power flow. This provide a different idea for solving the power flow. The paper uses the results of the IEEE5 node examples to illustrate the validity and practicality of the proposed method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhukov, A. V.; Komarov, A. N.; Safronov, A. N.
The principles of central control of the power generating units of thermal power plants by automatic secondary frequency and active power overcurrent regulation systems, and the algorithms for interactions between automatic power control systems for the power production units in thermal power plants and centralized systems for automatic frequency and power regulation, are discussed. The order of switching the power generating units of thermal power plants over to control by a centralized system for automatic frequency and power regulation and by the Central Coordinating System for automatic frequency and power regulation is presented. The results of full-scale system tests ofmore » the control of power generating units of the Kirishskaya, Stavropol, and Perm GRES (State Regional Electric Power Plants) by the Central Coordinating System for automatic frequency and power regulation at the United Power System of Russia on September 23-25, 2008, are reported.« less
Motor signatures of emotional reactivity in frontotemporal dementia.
Marshall, Charles R; Hardy, Chris J D; Russell, Lucy L; Clark, Camilla N; Bond, Rebecca L; Dick, Katrina M; Brotherhood, Emilie V; Mummery, Cath J; Schott, Jonathan M; Rohrer, Jonathan D; Kilner, James M; Warren, Jason D
2018-01-18
Automatic motor mimicry is essential to the normal processing of perceived emotion, and disrupted automatic imitation might underpin socio-emotional deficits in neurodegenerative diseases, particularly the frontotemporal dementias. However, the pathophysiology of emotional reactivity in these diseases has not been elucidated. We studied facial electromyographic responses during emotion identification on viewing videos of dynamic facial expressions in 37 patients representing canonical frontotemporal dementia syndromes versus 21 healthy older individuals. Neuroanatomical associations of emotional expression identification accuracy and facial muscle reactivity were assessed using voxel-based morphometry. Controls showed characteristic profiles of automatic imitation, and this response predicted correct emotion identification. Automatic imitation was reduced in the behavioural and right temporal variant groups, while the normal coupling between imitation and correct identification was lost in the right temporal and semantic variant groups. Grey matter correlates of emotion identification and imitation were delineated within a distributed network including primary visual and motor, prefrontal, insular, anterior temporal and temporo-occipital junctional areas, with common involvement of supplementary motor cortex across syndromes. Impaired emotional mimesis may be a core mechanism of disordered emotional signal understanding and reactivity in frontotemporal dementia, with implications for the development of novel physiological biomarkers of socio-emotional dysfunction in these diseases.
Nuclear engine flow reactivity shim control
Walsh, J.M.
1973-12-11
A nuclear engine control system is provided which automatically compensates for reactor reactivity uncertainties at the start of life and reactivity losses due to core corrosion during the reactor life in gas-cooled reactors. The coolant gas flow is varied automatically by means of specially provided control apparatus so that the reactor control drums maintain a predetermined steady state position throughout the reactor life. This permits the reactor to be designed for a constant drum position and results in a desirable, relatively flat temperature profile across the core. (Official Gazette)
46 CFR 161.002-9 - Automatic fire detecting system, power supply.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 6 2011-10-01 2011-10-01 false Automatic fire detecting system, power supply. 161.002-9 Section 161.002-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT...-9 Automatic fire detecting system, power supply. The power supply for an automatic fire detecting...
46 CFR 161.002-9 - Automatic fire detecting system, power supply.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 6 2010-10-01 2010-10-01 false Automatic fire detecting system, power supply. 161.002-9 Section 161.002-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT...-9 Automatic fire detecting system, power supply. The power supply for an automatic fire detecting...
46 CFR 112.05-5 - Emergency power source.
Code of Federal Regulations, 2013 CFR
2013-10-01
... with § 112.05-1(c). Table 112.05-5(a) Size of vessel and service Type of emergency power source or... power source (automatically connected storage battery or an automatically started generator) 36 hours.1... power source (automatically connected storage battery or an automatically started generator) 8 hours or...
46 CFR 112.05-5 - Emergency power source.
Code of Federal Regulations, 2012 CFR
2012-10-01
... with § 112.05-1(c). Table 112.05-5(a) Size of vessel and service Type of emergency power source or... power source (automatically connected storage battery or an automatically started generator) 36 hours.1... power source (automatically connected storage battery or an automatically started generator) 8 hours or...
46 CFR 112.05-5 - Emergency power source.
Code of Federal Regulations, 2014 CFR
2014-10-01
... with § 112.05-1(c). Table 112.05-5(a) Size of vessel and service Type of emergency power source or... power source (automatically connected storage battery or an automatically started generator) 36 hours.1... power source (automatically connected storage battery or an automatically started generator) 8 hours or...
Reactive Power Compensation Method Considering Minimum Effective Reactive Power Reserve
NASA Astrophysics Data System (ADS)
Gong, Yiyu; Zhang, Kai; Pu, Zhang; Li, Xuenan; Zuo, Xianghong; Zhen, Jiao; Sudan, Teng
2017-05-01
According to the calculation model of minimum generator reactive power reserve of power system voltage stability under the premise of the guarantee, the reactive power management system with reactive power compensation combined generator, the formation of a multi-objective optimization problem, propose a reactive power reserve is considered the minimum generator reactive power compensation optimization method. This method through the improvement of the objective function and constraint conditions, when the system load growth, relying solely on reactive power generation system can not meet the requirement of safe operation, increase the reactive power reserve to solve the problem of minimum generator reactive power compensation in the case of load node.
Curran, Scott J.; Gao, Zhiming; Wagner, Robert M.
2014-12-22
In-cylinder blending of gasoline and diesel to achieve reactivity-controlled compression ignition has been shown to reduce NO X and soot emissions while maintaining or improving brake thermal efficiency as compared with conventional diesel combustion. The reactivity-controlled compression ignition concept has an advantage over many advanced combustion strategies in that the fuel reactivity can be tailored to the engine speed and load, allowing stable low-temperature combustion to be extended over more of the light-duty drive cycle load range. In this paper, a multi-mode reactivity-controlled compression ignition strategy is employed where the engine switches from reactivity-controlled compression ignition to conventional diesel combustionmore » when speed and load demand are outside of the experimentally determined reactivity-controlled compression ignition range. The potential for reactivity-controlled compression ignition to reduce drive cycle fuel economy and emissions is not clearly understood and is explored here by simulating the fuel economy and emissions for a multi-mode reactivity-controlled compression ignition–enabled vehicle operating over a variety of US drive cycles using experimental engine maps for multi-mode reactivity-controlled compression ignition, conventional diesel combustion, and a 2009 port-fuel injected gasoline engine. Drive cycle simulations are completed assuming a conventional mid-size passenger vehicle with an automatic transmission. Multi-mode reactivity-controlled compression ignition fuel economy simulation results are compared with the same vehicle powered by a representative 2009 port-fuel injected gasoline engine over multiple drive cycles. Finally, engine-out drive cycle emissions are compared with conventional diesel combustion, and observations regarding relative gasoline and diesel tank sizes needed for the various drive cycles are also summarized.« less
46 CFR 112.05-5 - Emergency power source.
Code of Federal Regulations, 2011 CFR
2011-10-01
... generator must be either a diesel engine or a gas turbine. [CGD 74-125A, 47 FR 15267, Apr. 8, 1982, as... power source (automatically connected storage battery or an automatically started generator) 36 hours.1... power source (automatically connected storage battery or an automatically started generator) 8 hours or...
46 CFR 112.05-5 - Emergency power source.
Code of Federal Regulations, 2010 CFR
2010-10-01
... generator must be either a diesel engine or a gas turbine. [CGD 74-125A, 47 FR 15267, Apr. 8, 1982, as... power source (automatically connected storage battery or an automatically started generator) 36 hours.1... power source (automatically connected storage battery or an automatically started generator) 8 hours or...
14 CFR 29.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2011 CFR
2011-01-01
... power-operated systems. 29.672 Section 29.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 29.672 Stability augmentation, automatic, and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated system is necessary to show...
14 CFR 29.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2014 CFR
2014-01-01
... power-operated systems. 29.672 Section 29.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 29.672 Stability augmentation, automatic, and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated system is necessary to show...
14 CFR 27.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2014 CFR
2014-01-01
... power-operated systems. 27.672 Section 27.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 27.672 Stability augmentation, automatic, and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated systems is necessary to show...
14 CFR 29.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
... power-operated systems. 29.672 Section 29.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 29.672 Stability augmentation, automatic, and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated system is necessary to show...
14 CFR 27.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2011 CFR
2011-01-01
... power-operated systems. 27.672 Section 27.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 27.672 Stability augmentation, automatic, and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated systems is necessary to show...
14 CFR 29.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2012 CFR
2012-01-01
... power-operated systems. 29.672 Section 29.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 29.672 Stability augmentation, automatic, and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated system is necessary to show...
14 CFR 27.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
... power-operated systems. 27.672 Section 27.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 27.672 Stability augmentation, automatic, and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated systems is necessary to show...
14 CFR 27.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2012 CFR
2012-01-01
... power-operated systems. 27.672 Section 27.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 27.672 Stability augmentation, automatic, and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated systems is necessary to show...
14 CFR 25.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2013 CFR
2013-01-01
... power-operated systems. 25.672 Section 25.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 25.672 Stability augmentation and automatic and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated systems is necessary to show...
Initial Comparison of Direct and Legacy Modeling Approaches for Radial Core Expansion Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shemon, Emily R.
2016-10-10
Radial core expansion in sodium-cooled fast reactors provides an important reactivity feedback effect. As the reactor power increases due to normal start up conditions or accident scenarios, the core and surrounding materials heat up, causing both grid plate expansion and bowing of the assembly ducts. When the core restraint system is designed correctly, the resulting structural deformations introduce negative reactivity which decreases the reactor power. Historically, an indirect procedure has been used to estimate the reactivity feedback due to structural deformation which relies upon perturbation theory and coupling legacy physics codes with limited geometry capabilities. With advancements in modeling andmore » simulation, radial core expansion phenomena can now be modeled directly, providing an assessment of the accuracy of the reactivity feedback coefficients generated by indirect legacy methods. Recently a new capability was added to the PROTEUS-SN unstructured geometry neutron transport solver to analyze deformed meshes quickly and directly. By supplying the deformed mesh in addition to the base configuration input files, PROTEUS-SN automatically processes material adjustments including calculation of region densities to conserve mass, calculation of isotopic densities according to material models (for example, sodium density as a function of temperature), and subsequent re-homogenization of materials. To verify the new capability of directly simulating deformed meshes, PROTEUS-SN was used to compute reactivity feedback for a series of contrived yet representative deformed configurations for the Advanced Burner Test Reactor design. The indirect legacy procedure was also performed to generate reactivity feedback coefficients for the same deformed configurations. Interestingly, the legacy procedure consistently overestimated reactivity feedbacks by 35% compared to direct simulations by PROTEUS-SN. This overestimation indicates that the legacy procedures are in fact not conservative and could be overestimating reactivity feedback effects that are closely tied to reactor safety. We conclude that there is indeed value in performing direct simulation of deformed meshes despite the increased computational expense. PROTEUS-SN is already part of the SHARP multi-physics toolkit where both thermal hydraulics and structural mechanical feedback modeling can be applied but this is the first comparison of direct simulation to legacy techniques for radial core expansion.« less
The Naive Misuse of Power: Nonconscious Sources of Sexual Harassment.
ERIC Educational Resources Information Center
Bargh, John A.; Raymond, Paula
1995-01-01
Considers sexual harassment from the perspective of abuse of power, and discusses the possibility of having power within a situation that automatically and nonconsciously triggers a sexuality schema, just as racial or gender features automatically trigger stereotypes of that group. The possible origins of the automatic power/sex linkage and its…
Identifying cognitive predictors of reactive and proactive aggression.
Brugman, Suzanne; Lobbestael, Jill; Arntz, Arnoud; Cima, Maaike; Schuhmann, Teresa; Dambacher, Franziska; Sack, Alexander T
2015-01-01
The aim of this study was to identify implicit cognitive predictors of aggressive behavior. Specifically, the predictive value of an attentional bias for aggressive stimuli and automatic association of the self and aggression was examined for reactive and proactive aggressive behavior in a non-clinical sample (N = 90). An Emotional Stroop Task was used to measure an attentional bias. With an idiographic Single-Target Implicit Association Test, automatic associations were assessed between words referring to the self (e.g., the participants' name) and words referring to aggression (e.g., fighting). The Taylor Aggression Paradigm (TAP) was used to measure reactive and proactive aggressive behavior. Furthermore, self-reported aggressiveness was assessed with the Reactive Proactive Aggression Questionnaire (RPQ). Results showed that heightened attentional interference for aggressive words significantly predicted more reactive aggression, while lower attentional bias towards aggressive words predicted higher levels of proactive aggression. A stronger self-aggression association resulted in more proactive aggression, but not reactive aggression. Self-reports on aggression did not additionally predict behavioral aggression. This implies that the cognitive tests employed in our study have the potential to discriminate between reactive and proactive aggression. Aggr. Behav. 41:51-64 2015. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Ngamroo, Issarachai
2010-12-01
It is well known that the superconducting magnetic energy storage (SMES) is able to quickly exchange active and reactive power with the power system. The SMES is expected to be the smart storage device for power system stabilization. Although the stabilizing effect of SMES is significant, the SMES is quite costly. Particularly, the superconducting magnetic coil size which is the essence of the SMES, must be carefully selected. On the other hand, various generation and load changes, unpredictable network structure, etc., cause system uncertainties. The power controller of SMES which is designed without considering such uncertainties, may not tolerate and loses stabilizing effect. To overcome these problems, this paper proposes the new design of robust SMES controller taking coil size and system uncertainties into account. The structure of the active and reactive power controllers is the 1st-order lead-lag compensator. No need for the exact mathematical representation, system uncertainties are modeled by the inverse input multiplicative perturbation. Without the difficulty of the trade-off of damping performance and robustness, the optimization problem of control parameters is formulated. The particle swarm optimization is used for solving the optimal parameters at each coil size automatically. Based on the normalized integral square error index and the consideration of coil current constraint, the robust SMES with the smallest coil size which still provides the satisfactory stabilizing effect, can be achieved. Simulation studies in the two-area four-machine interconnected power system show the superior robustness of the proposed robust SMES with the smallest coil size under various operating conditions over the non-robust SMES with large coil size.
Automatic Layout Design for Power Module
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ning, Puqi; Wang, Fei; Ngo, Khai
The layout of power modules is one of the most important elements in power module design, especially for high power densities, where couplings are increased. In this paper, an automatic design process using a genetic algorithm is presented. Some practical considerations are introduced in the optimization of the layout design of the module. This paper presents a process for automatic layout design for high power density modules. Detailed GA implementations are introduced both for outer loop and inner loop. As verified by a design example, the results of the automatic design process presented here are better than those from manualmore » design and also better than the results from a popular design software. This automatic design procedure could be a major step toward improving the overall performance of future layout design.« less
A comprehensive approach to reactive power scheduling in restructured power systems
NASA Astrophysics Data System (ADS)
Shukla, Meera
Financial constraints, regulatory pressure, and need for more economical power transfers have increased the loading of interconnected transmission systems. As a consequence, power systems have been operated close to their maximum power transfer capability limits, making the system more vulnerable to voltage instability events. The problem of voltage collapse characterized by a severe local voltage depression is generally believed to be associated with inadequate VAr support at key buses. The goal of reactive power planning is to maintain a high level of voltage security, through installation of properly sized and located reactive sources and their optimal scheduling. In case of vertically-operated power systems, the reactive requirement of the system is normally satisfied by using all of its reactive sources. But in case of different scenarios of restructured power systems, one may consider a fixed amount of exchange of reactive power through tie lines. Reviewed literature suggests a need for optimal scheduling of reactive power generation for fixed inter area reactive power exchange. The present work proposed a novel approach for reactive power source placement and a novel approach for its scheduling. The VAr source placement technique was based on the property of system connectivity. This is followed by development of optimal reactive power dispatch formulation which facilitated fixed inter area tie line reactive power exchange. This formulation used a Line Flow-Based (LFB) model of power flow analysis. The formulation determined the generation schedule for fixed inter area tie line reactive power exchange. Different operating scenarios were studied to analyze the impact of VAr management approach for vertically operated and restructured power systems. The system loadability, losses, generation and the cost of generation were the performance measures to study the impact of VAr management strategy. The novel approach was demonstrated on IEEE 30 bus system.
Albares, Marion; Lio, Guillaume; Criaud, Marion; Anton, Jean-Luc; Desmurget, Michel; Boulinguez, Philippe
2014-11-01
Response inhibition is commonly thought to rely on voluntary, reactive, selective, and relatively slow prefrontal mechanisms. In contrast, we suggest here that response inhibition is achieved automatically, nonselectively, within very short delays in uncertain environments. We modified a classical go/nogo protocol to probe context-dependent inhibitory mechanisms. Because no single neuroimaging method can definitely disentangle neural excitation and inhibition, we combined fMRI and EEG recordings in healthy humans. Any stimulus (go or nogo) presented in an uncertain context requiring action restraint was found to evoke activity changes in the supplementary motor complex (SMC) with respect to a control condition in which no response inhibition was required. These changes included: (1) An increase in event-related BOLD activity, (2) an attenuation of the early (170 ms) event related potential generated by a single, consistent source isolated by advanced blind source separation, and (3) an increase in the evoked-EEG Alpha power of this source. Considered together, these results suggest that the BOLD signal evoked by any stimulus in the SMC when the situation is unpredictable can be driven by automatic, nonselective, context-dependent inhibitory activities. This finding reveals the paradoxical mechanisms by which voluntary control of action may be achieved. The ability to provide controlled responses in unpredictable environments would require setting-up the automatic self-inhibitory circuitry within the SMC. Conversely, enabling automatic behavior when the environment becomes predictable would require top-down control to deactivate anticipatorily and temporarily the inhibitory set. Copyright © 2014 Wiley Periodicals, Inc.
14 CFR 25.904 - Automatic takeoff thrust control system (ATTCS).
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Automatic takeoff thrust control system... Automatic takeoff thrust control system (ATTCS). Each applicant seeking approval for installation of an engine power control system that automatically resets the power or thrust on the operating engine(s) when...
14 CFR 25.904 - Automatic takeoff thrust control system (ATTCS).
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Automatic takeoff thrust control system... Automatic takeoff thrust control system (ATTCS). Each applicant seeking approval for installation of an engine power control system that automatically resets the power or thrust on the operating engine(s) when...
NASA Technical Reports Server (NTRS)
Watson, D. M.; Hardy, G. H.; Warner, D. N., Jr.
1983-01-01
An automatic landing system was developed for the Augmentor Wing Jet STOL Research Airplane to establish the feasibility and examine the operating characteristics of a powered-lift STOL transport flying a steep, microwave landing system (MLS) glide slope to automatically land on a STOL port. The flight test results address the longitudinal aspects of automatic powered lift STOL airplane operation including glide slope tracking on the backside of the power curve, flare, and touchdown. Three different autoland control laws were evaluated to demonstrate the tradeoff between control complexity and the resulting performance. The flight test and simulation methodology used in developing conventional jet transport systems was applied to the powered-lift STOL airplane. The results obtained suggest that an automatic landing system for a powered-lift STOL airplane operating into an MLS-equipped STOL port is feasible. However, the airplane must be provided with a means of rapidly regulation lift to satisfactorily provide the glide slope tracking and control of touchdown sink rate needed for automatic landings.
Adaptive Q–V Scheme for the Voltage Control of a DFIG-Based Wind Power Plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jinho; Seok, Jul-Ki; Muljadi, Eduard
Wind generators within a wind power plant (WPP) will produce different amounts of active power because of the wake effect, and therefore, they have different reactive power capabilities. This paper proposes an adaptive reactive power to the voltage (Q-V) scheme for the voltage control of a doubly fed induction generator (DFIG)-based WPP. In the proposed scheme, the WPP controller uses a voltage control mode and sends a voltage error signal to each DFIG. The DFIG controller also employs a voltage control mode utilizing the adaptive Q-V characteristics depending on the reactive power capability such that a DFIG with a largermore » reactive power capability will inject more reactive power to ensure fast voltage recovery. Test results indicate that the proposed scheme can recover the voltage within a short time, even for a grid fault with a small short-circuit ratio, by making use of the available reactive power of a WPP and differentiating the reactive power injection in proportion to the reactive power capability. This will, therefore, help to reduce the additional reactive power and ensure fast voltage recovery.« less
Secure provision of reactive power ancillary services in competitive electricity markets
NASA Astrophysics Data System (ADS)
El-Samahy, Ismael
The research work presented in this thesis discusses various complex issues associated with reactive power management and pricing in the context of new operating paradigms in deregulated power systems, proposing appropriate policy solutions. An integrated two-level framework for reactive power management is set forth, which is both suitable for a competitive market and ensures a secure and reliable operation of the associated power system. The framework is generic in nature and can be adopted for any electricity market structure. The proposed hierarchical reactive power market structure comprises two stages: procurement of reactive power resources on a seasonal basis, and real-time reactive power dispatch. The main objective of the proposed framework is to provide appropriate reactive power support from service providers at least cost, while ensuring a secure operation of the power system. The proposed procurement procedure is based on a two-step optimization model. First, the marginal benefits of reactive power supply from each provider, with respect to system security, are obtained by solving a loadability-maximization problem subject to transmission security constraints imposed by voltage and thermal limits. Second, the selected set of generators is determined by solving an optimal power flow (OPF)-based auction. This auction maximizes a societal advantage function comprising generators' offers and their corresponding marginal benefits with respect to system security, and considering all transmission system constraints. The proposed procedure yields the selected set of generators and zonal price components, which would form the basis for seasonal contracts between the system operator and the selected reactive power service providers. The main objective of the proposed reactive power dispatch model is to minimize the total payment burden on the Independent System Operator (ISO), which is associated with reactive power dispatch. The real power generation is decoupled and assumed to be fixed during the reactive power dispatch procedures; however, the effect of reactive power on real power is considered in the model by calculating the required reduction in real power output of a generator due to an increase in its reactive power supply. In this case, real power generation is allowed to be rescheduled, within given limits, from the already dispatched levels obtained from the energy market clearing process. The proposed dispatch model achieves the main objective of an ISO in a competitive electricity market, which is to provide the required reactive power support from generators at least cost while ensuring a secure operation of the power system. The proposed reactive power procurement and dispatch models capture both the technical and economic aspects of power system operation in competitive electricity markets; however, from an optimization point of view, these models represent non-convex mixed integer non-linear programming (MINLP) problems due to the presence of binary variables associated with the different regions of reactive power operation in a synchronous generator. Such MINLP optimization problems are difficult to solve, especially for an actual power system. A novel Generator Reactive Power Classification (GRPC) algorithm is proposed in this thesis to address this issue, with the advantage of iteratively solving the optimization models as a series of non-linear programming (NLP) sub-problems. The proposed reactive power procurement and dispatch models are implemented and tested on the CIGRE 32-bus system, with several case studies that represent different practical operating scenarios. The developed models are also compared with other approaches for reactive power provision, and the results demonstrate the robustness and effectiveness of the proposed model. The results clearly reveal the main features of the proposed models for optimal provision of reactive power ancillary service, in order to suit the requirements of an ISO under today's stressed system conditions in a competitive market environment.
Episodic Memory Retrieval Functionally Relies on Very Rapid Reactivation of Sensory Information.
Waldhauser, Gerd T; Braun, Verena; Hanslmayr, Simon
2016-01-06
Episodic memory retrieval is assumed to rely on the rapid reactivation of sensory information that was present during encoding, a process termed "ecphory." We investigated the functional relevance of this scarcely understood process in two experiments in human participants. We presented stimuli to the left or right of fixation at encoding, followed by an episodic memory test with centrally presented retrieval cues. This allowed us to track the reactivation of lateralized sensory memory traces during retrieval. Successful episodic retrieval led to a very early (∼100-200 ms) reactivation of lateralized alpha/beta (10-25 Hz) electroencephalographic (EEG) power decreases in the visual cortex contralateral to the visual field at encoding. Applying rhythmic transcranial magnetic stimulation to interfere with early retrieval processing in the visual cortex led to decreased episodic memory performance specifically for items encoded in the visual field contralateral to the site of stimulation. These results demonstrate, for the first time, that episodic memory functionally relies on very rapid reactivation of sensory information. Remembering personal experiences requires a "mental time travel" to revisit sensory information perceived in the past. This process is typically described as a controlled, relatively slow process. However, by using electroencephalography to measure neural activity with a high time resolution, we show that such episodic retrieval entails a very rapid reactivation of sensory brain areas. Using transcranial magnetic stimulation to alter brain function during retrieval revealed that this early sensory reactivation is causally relevant for conscious remembering. These results give first neural evidence for a functional, preconscious component of episodic remembering. This provides new insight into the nature of human memory and may help in the understanding of psychiatric conditions that involve the automatic intrusion of unwanted memories. Copyright © 2016 the authors 0270-6474/16/360251-10$15.00/0.
Reactive Power Pricing Model Considering the Randomness of Wind Power Output
NASA Astrophysics Data System (ADS)
Dai, Zhong; Wu, Zhou
2018-01-01
With the increase of wind power capacity integrated into grid, the influence of the randomness of wind power output on the reactive power distribution of grid is gradually highlighted. Meanwhile, the power market reform puts forward higher requirements for reasonable pricing of reactive power service. Based on it, the article combined the optimal power flow model considering wind power randomness with integrated cost allocation method to price reactive power. Meanwhile, considering the advantages and disadvantages of the present cost allocation method and marginal cost pricing, an integrated cost allocation method based on optimal power flow tracing is proposed. The model realized the optimal power flow distribution of reactive power with the minimal integrated cost and wind power integration, under the premise of guaranteeing the balance of reactive power pricing. Finally, through the analysis of multi-scenario calculation examples and the stochastic simulation of wind power outputs, the article compared the results of the model pricing and the marginal cost pricing, which proved that the model is accurate and effective.
14 CFR Appendix H to Part 23 - Installation of An Automatic Power Reserve (APR) System
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Installation of An Automatic Power Reserve (APR) System H Appendix H to Part 23 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT... AIRPLANES Pt. 23, App. H Appendix H to Part 23—Installation of An Automatic Power Reserve (APR) System H23.1...
77 FR 11109 - Reactive Power Resources; Notice of Technical Conference
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-24
... options for and cost of installing reactive power equipment at the time of interconnection as well as... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. AD12-10-000] Reactive Power... the need for reactive power capability among newly interconnecting asynchronous generators and raises...
77 FR 21555 - Reactive Power Resources; Supplemental Notice of Technical Conference
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-10
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. AD12-10-000] Reactive Power... Commission (Commission) announced that a staff Technical Conference on Reactive Power Resources will be held... may register at the following Web page: https://www.ferc.gov/whats-new/registration/reactive-power-4...
77 FR 24949 - Reactive Power Resources; Supplemental Notice Requesting Comments
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-26
... storage resources; the design options for and cost of installing reactive power equipment at the time of... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. AD12-10-000] Reactive Power... the reactive power provisions of Order No. 661-A and examine what evidence could be developed under...
46 CFR 58.25-30 - Automatic restart.
Code of Federal Regulations, 2014 CFR
2014-10-01
... auxiliary steering gear and each power actuating system must restart automatically when electrical power is... 46 Shipping 2 2014-10-01 2014-10-01 false Automatic restart. 58.25-30 Section 58.25-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY...
46 CFR 58.25-30 - Automatic restart.
Code of Federal Regulations, 2013 CFR
2013-10-01
... auxiliary steering gear and each power actuating system must restart automatically when electrical power is... 46 Shipping 2 2013-10-01 2013-10-01 false Automatic restart. 58.25-30 Section 58.25-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY...
46 CFR 58.25-30 - Automatic restart.
Code of Federal Regulations, 2012 CFR
2012-10-01
... auxiliary steering gear and each power actuating system must restart automatically when electrical power is... 46 Shipping 2 2012-10-01 2012-10-01 false Automatic restart. 58.25-30 Section 58.25-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY...
46 CFR 58.25-30 - Automatic restart.
Code of Federal Regulations, 2011 CFR
2011-10-01
... auxiliary steering gear and each power actuating system must restart automatically when electrical power is... 46 Shipping 2 2011-10-01 2011-10-01 false Automatic restart. 58.25-30 Section 58.25-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY...
46 CFR 58.25-30 - Automatic restart.
Code of Federal Regulations, 2010 CFR
2010-10-01
... auxiliary steering gear and each power actuating system must restart automatically when electrical power is... 46 Shipping 2 2010-10-01 2010-10-01 false Automatic restart. 58.25-30 Section 58.25-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY...
Preliminary Evidence for an Automatic Link between Sex and Power among Men Who Molest Children
ERIC Educational Resources Information Center
Kamphuis, Jan H.; De Ruiter, Corine; Janssen, Bas; Spiering, Mark
2005-01-01
Understanding critical motivational processes of sexual offenders may ultimately provide important clues to more effective treatments. Implicit, automatic cognitive processes have received minimal attention; however, a lexical decision experiment revealed automatic links between the concepts of power and sex among participants who self-reported…
Neural systems for preparatory control of imitation.
Cross, Katy A; Iacoboni, Marco
2014-01-01
Humans have an automatic tendency to imitate others. Previous studies on how we control these tendencies have focused on reactive mechanisms, where inhibition of imitation is implemented after seeing an action. This work suggests that reactive control of imitation draws on at least partially specialized mechanisms. Here, we examine preparatory imitation control, where advance information allows control processes to be employed before an action is observed. Drawing on dual route models from the spatial compatibility literature, we compare control processes using biological and non-biological stimuli to determine whether preparatory imitation control recruits specialized neural systems that are similar to those observed in reactive imitation control. Results indicate that preparatory control involves anterior prefrontal, dorsolateral prefrontal, posterior parietal and early visual cortices regardless of whether automatic responses are evoked by biological (imitative) or non-biological stimuli. These results indicate both that preparatory control of imitation uses general mechanisms, and that preparatory control of imitation draws on different neural systems from reactive imitation control. Based on the regions involved, we hypothesize that preparatory control is implemented through top-down attentional biasing of visual processing.
Optimization of Equation of State and Burn Model Parameters for Explosives
NASA Astrophysics Data System (ADS)
Bergh, Magnus; Wedberg, Rasmus; Lundgren, Jonas
2017-06-01
A reactive burn model implemented in a multi-dimensional hydrocode can be a powerful tool for predicting non-ideal effects as well as initiation phenomena in explosives. Calibration against experiment is, however, critical and non-trivial. Here, a procedure is presented for calibrating the Ignition and Growth Model utilizing hydrocode simulation in conjunction with the optimization program LS-OPT. The model is applied to the explosive PBXN-109. First, a cylinder expansion test is presented together with a new automatic routine for product equation of state calibration. Secondly, rate stick tests and instrumented gap tests are presented. Data from these experiments are used to calibrate burn model parameters. Finally, we discuss the applicability and development of this optimization routine.
An accurate reactive power control study in virtual flux droop control
NASA Astrophysics Data System (ADS)
Wang, Aimeng; Zhang, Jia
2017-12-01
This paper investigates the problem of reactive power sharing based on virtual flux droop method. Firstly, flux droop control method is derived, where complicated multiple feedback loops and parameter regulation are avoided. Then, the reasons for inaccurate reactive power sharing are theoretically analyzed. Further, a novel reactive power control scheme is proposed which consists of three parts: compensation control, voltage recovery control and flux droop control. Finally, the proposed reactive power control strategy is verified in a simplified microgrid model with two parallel DGs. The simulation results show that the proposed control scheme can achieve accurate reactive power sharing and zero deviation of voltage. Meanwhile, it has some advantages of simple control and excellent dynamic and static performance.
Automatic Layout Design for Power Module
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ning, Puqi; Wang, Fei; Ngo, Khai
The layout of power modules is one of the key points in power module design, especially for high power densities, where couplings are increased. In this paper, along with the design example, an automatic design processes by using a genetic algorithm are presented. Some practical considerations and implementations are introduced in the optimization of module layout design.
46 CFR 112.01-10 - Automatic emergency lighting and power system.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Automatic emergency lighting and power system. 112.01-10 Section 112.01-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-10...
46 CFR 112.01-10 - Automatic emergency lighting and power system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Automatic emergency lighting and power system. 112.01-10 Section 112.01-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-10...
46 CFR 112.01-10 - Automatic emergency lighting and power system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Automatic emergency lighting and power system. 112.01-10 Section 112.01-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-10...
46 CFR 112.01-10 - Automatic emergency lighting and power system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Automatic emergency lighting and power system. 112.01-10 Section 112.01-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-10...
46 CFR 112.01-10 - Automatic emergency lighting and power system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Automatic emergency lighting and power system. 112.01-10 Section 112.01-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-10...
1995-06-01
Energy efficient, 30 and 40 watt ballasts are Rapid Start, thermally protected, automatic resetting. Class P, high or low power factor as required...BALLASTS Energy efficient, 30 ana 40 watt Rapic Start, thermally protected, automatic resetting. Class P. high power factor, CEM, sound rated A. unless...BALLASTS Energy efficient, 40 Watt Rapid Start, thermally protected, automatic resetting, Class P, high power factor, CBM, sound rated A, unless
Keleş Altun, İlkay; Uysal, Emel; Özkorumak Karagüzel, Evrim
2017-01-01
Obsessive compulsive disorder (OCD) is characterized by obsessions and compulsions. Obsessions have been classified as autogenous obsessions and reactive obsessions on the basis of the cognitive theory of Lee and Kwon. The aim of this study was to investigate the differences between autogenous groups (AG) and reactive groups (RG) in terms of metacognition and automatic thoughts, for the purpose of investigating the differences of cognitive appraisals. One hundred and thirty-three patients diagnosed with OCD were included in the study as the patient group. A control group was formed of 133 age, gender and education-matched healthy individuals. The OCD group patients were separated into subgroups according to the primary obsessions. The sociodemographic data, and the Yale-Brown Obsessive Compulsive Scale, Metacognition Questionnaire-30 (MCQ-30), Automatic Thoughts Questionnaire (ATQ), Beck Depression Inventory (BDI) and Beck Anxiety Inventory (BAI) scores of the AG, RG, and control groups were compared. The MCQ-30 (total) and the subscales of MCQ-30 and ATQ scale points were seen to be significantly higher in the AG than in the RG and significantly higher in the RG than in the control group. In the reactive obsession group, the predictive variables of the ATQ points were determined to be MCQ-30 (total), BDI and BAI. In the autogenous obsession group, the predictive variables of the ATQ points were determined to be BDI and BAI. In the current study, differences were determined between the AG and the RG in respect of metacognitions and automatic thoughts. In light of these results, the recommended grouping can be considered useful in the identification of OCD sub-types. There is a need for further studies to identify more homogenous sub-types of OCD. Future multi-centered studies of sub-typing with larger samples using more specific instruments to sub-type and dimensional evaluation will be useful for detailed evaluation and better understanding of the subject.
Voices from "The Front": How Student Violence Is Changing the Experience of School Leaders
ERIC Educational Resources Information Center
McAdams, Charles R., III; Foster, Victoria A.
2008-01-01
The nature of student violence in America's schools has changed over the past two decades. Research suggests that there are two distinct kinds or "subtypes" of aggression in youth-reactive aggression and proactive aggression. Reactive aggression is characterized as a "hot-blooded," automatic, defensive response to immediate and often misperceived…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-05
... Automatic Power Reserve (APR), an Automatic Takeoff Thrust Control System (ATTCS), for Go-Around Performance... airplane will have novel or unusual design features associated with utilizing go-around performance credit...: Federal eRegulations Portal: Go to http://www.regulations.gov/ and follow the online instructions for...
Calibrating reaction rates for the CREST model
NASA Astrophysics Data System (ADS)
Handley, Caroline A.; Christie, Michael A.
2017-01-01
The CREST reactive-burn model uses entropy-dependent reaction rates that, until now, have been manually tuned to fit shock-initiation and detonation data in hydrocode simulations. This paper describes the initial development of an automatic method for calibrating CREST reaction-rate coefficients, using particle swarm optimisation. The automatic method is applied to EDC32, to help develop the first CREST model for this conventional high explosive.
Evaluation of Contribution for Voltage Control Ancillary Services Based on Social Surplus
NASA Astrophysics Data System (ADS)
Ueki, Yuji; Hara, Ryoichi; Kita, Hiroyuki; Hasegawa, Jun
Reactive power supply plays an important role in active power supply with adequate system voltages. Various pricing mechanism for reactive power supply have been developed and some of them are adopted in some power systems, however they are in a trial stage. The authors also focus on development of a pricing method for reactive power ancillary services. This problem involves two technical issues: rational estimation of the cost associated with reactive power supply and fair and transparent allocation of the estimated cost among the market participants. This paper proposes methods for evaluating the contribution of generators and demands.
Substation Reactive Power Regulation Strategy
NASA Astrophysics Data System (ADS)
Zhang, Junfeng; Zhang, Chunwang; Ma, Daqing
2018-01-01
With the increasing requirements on the power supply quality and reliability of distribution network, voltage and reactive power regulation of substations has become one of the indispensable ways to ensure voltage quality and reactive power balance and to improve the economy and reliability of distribution network. Therefore, it is a general concern of the current power workers and operators that what kind of flexible and effective control method should be used to adjust the on-load tap-changer (OLTC) transformer and shunt compensation capacitor in a substation to achieve reactive power balance in situ, improve voltage pass rate, increase power factor and reduce active power loss. In this paper, based on the traditional nine-zone diagram and combining with the characteristics of substation, a fuzzy variable-center nine-zone diagram control method is proposed and used to make a comprehensive regulation of substation voltage and reactive power. Through the calculation and simulation of the example, this method is proved to have satisfactorily reconciled the contradiction between reactive power and voltage in real-time control and achieved the basic goal of real-time control of the substation, providing a reference value to the practical application of the substation real-time control method.
Bargh, J A; Raymond, P; Pryor, J B; Strack, F
1995-05-01
One characteristic of men who sexually harass is that they are not aware that their actions are inappropriate or a misuse of their power (L. F. Fitzgerald, 1993a). We investigated the existence and automaticity of a mental association between the concepts of power and sex, and its consequences for sexual harassment tendencies. Using a subliminal priming paradigm, Experiment 1 demonstrated an automatic link between power and sex, and only for men high in the likelihood to sexually harass or aggress. In Experiment 2, male participants were unobtrusively primed with either power-related or neutral stimuli. For men likely to sexually aggress, but not other participants, attraction ratings of a female confederate were significantly higher in the power priming than the neutral priming condition.
Installation of automatic control at experimental breeder reactor II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larson, H.A.; Booty, W.F.; Chick, D.R.
1985-08-01
The Experimental Breeder Reactor II (EBR-II) has been modified to permit automatic control capability. Necessary mechanical and electrical changes were made on a regular control rod position; motor, gears, and controller were replaced. A digital computer system was installed that has the programming capability for varied power profiles. The modifications permit transient testing at EBR-II. Experiments were run that increased power linearly as much as 4 MW/s (16% of initial power of 25 MW(thermal)/s), held power constant, and decreased power at a rate no slower than the increase rate. Thus the performance of the automatic control algorithm, the mechanical andmore » electrical control equipment, and the qualifications of the driver fuel for future power change experiments were all demonstrated.« less
Applying reliability analysis to design electric power systems for More-electric aircraft
NASA Astrophysics Data System (ADS)
Zhang, Baozhu
The More-Electric Aircraft (MEA) is a type of aircraft that replaces conventional hydraulic and pneumatic systems with electrically powered components. These changes have significantly challenged the aircraft electric power system design. This thesis investigates how reliability analysis can be applied to automatically generate system topologies for the MEA electric power system. We first use a traditional method of reliability block diagrams to analyze the reliability level on different system topologies. We next propose a new methodology in which system topologies, constrained by a set reliability level, are automatically generated. The path-set method is used for analysis. Finally, we interface these sets of system topologies with control synthesis tools to automatically create correct-by-construction control logic for the electric power system.
14 CFR Appendix I to Part 25 - Installation of an Automatic Takeoff Thrust Control System (ATTCS)
Code of Federal Regulations, 2010 CFR
2010-01-01
...) This appendix specifies additional requirements for installation of an engine power control system that... crew to increase thrust or power. I25.2Definitions. (a) Automatic Takeoff Thrust Control System (ATTCS... mechanical and electrical, that sense engine failure, transmit signals, actuate fuel controls or power levers...
Effects of voluntary and automatic control of center of pressure sway during quiet standing.
Ueta, Kozo; Okada, Yohei; Nakano, Hideki; Osumi, Michihiro; Morioka, Shu
2015-01-01
The authors investigated the effects of voluntary and automatic control on the spatial variables (envelope area, maximal amplitude, and root mean square [RMS]) of center of pressure (COP) displacement during quiet standing and identified differences in their postural control strategies (mean velocity [MV], mean power frequency [MPF], and power density). COP data were recorded under relaxed (experimental control), still (voluntary control), and dual (automatic control) conditions. RMS was significantly lower in the still and dual conditions than in the relaxed condition. MV, MPF, and power density were significantly higher in the still condition than in the dual condition. These results indicate that both voluntary and automatic control decrease the spatial variables of COP displacement; however, their postural control strategies are different.
Optimal generator bidding strategies for power and ancillary services
NASA Astrophysics Data System (ADS)
Morinec, Allen G.
As the electric power industry transitions to a deregulated market, power transactions are made upon price rather than cost. Generator companies are interested in maximizing their profits rather than overall system efficiency. A method to equitably compensate generation providers for real power, and ancillary services such as reactive power and spinning reserve, will ensure a competitive market with an adequate number of suppliers. Optimizing the generation product mix during bidding is necessary to maximize a generator company's profits. The objective of this research work is to determine and formulate appropriate optimal bidding strategies for a generation company in both the energy and ancillary services markets. These strategies should incorporate the capability curves of their generators as constraints to define the optimal product mix and price offered in the day-ahead and real time spot markets. In order to achieve such a goal, a two-player model was composed to simulate market auctions for power generation. A dynamic game methodology was developed to identify Nash Equilibria and Mixed-Strategy Nash Equilibria solutions as optimal generation bidding strategies for two-player non-cooperative variable-sum matrix games with incomplete information. These games integrated the generation product mix of real power, reactive power, and spinning reserve with the generators's capability curves as constraints. The research includes simulations of market auctions, where strategies were tested for generators with different unit constraints, costs, types of competitors, strategies, and demand levels. Studies on the capability of large hydrogen cooled synchronous generators were utilized to derive useful equations that define the exact shape of the capability curve from the intersections of the arcs defined by the centers and radial vectors of the rotor, stator, and steady-state stability limits. The available reactive reserve and spinning reserve were calculated given a generator operating point in the P-Q plane. Four computer programs were developed to automatically perform the market auction simulations using the equal incremental cost rule. The software calculates the payoffs for the two competing competitors, dispatches six generators, and allocates ancillary services for 64 combinations of bidding strategies, three levels of system demand, and three different types of competitors. Matrix Game theory was utilized to calculate Nash Equilibrium solutions and mixed-strategy Nash solutions as the optimal generator bidding strategies. A method to incorporate ancillary services into the generation bidding strategy, to assure an adequate supply of ancillary services, and to allocate these necessary resources to the on-line units was devised. The optimal generator bid strategy in a power auction was shown to be the Nash Equilibrium solution found in two-player variable-sum matrix games.
Patrick, Regan E; Rastogi, Anuj; Christensen, Bruce K
2015-01-01
Adaptive emotional responding relies on dual automatic and effortful processing streams. Dual-stream models of schizophrenia (SCZ) posit a selective deficit in neural circuits that govern goal-directed, effortful processes versus reactive, automatic processes. This imbalance suggests that when patients are confronted with competing automatic and effortful emotional response cues, they will exhibit diminished effortful responding and intact, possibly elevated, automatic responding compared to controls. This prediction was evaluated using a modified version of the face-vignette task (FVT). Participants viewed emotional faces (automatic response cue) paired with vignettes (effortful response cue) that signalled a different emotion category and were instructed to discriminate the manifest emotion. Patients made less vignette and more face responses than controls. However, the relationship between group and FVT responding was moderated by IQ and reading comprehension ability. These results replicate and extend previous research and provide tentative support for abnormal conflict resolution between automatic and effortful emotional processing predicted by dual-stream models of SCZ.
An autonomous organic reaction search engine for chemical reactivity.
Dragone, Vincenza; Sans, Victor; Henson, Alon B; Granda, Jaroslaw M; Cronin, Leroy
2017-06-09
The exploration of chemical space for new reactivity, reactions and molecules is limited by the need for separate work-up-separation steps searching for molecules rather than reactivity. Herein we present a system that can autonomously evaluate chemical reactivity within a network of 64 possible reaction combinations and aims for new reactivity, rather than a predefined set of targets. The robotic system combines chemical handling, in-line spectroscopy and real-time feedback and analysis with an algorithm that is able to distinguish and select the most reactive pathways, generating a reaction selection index (RSI) without need for separate work-up or purification steps. This allows the automatic navigation of a chemical network, leading to previously unreported molecules while needing only to do a fraction of the total possible reactions without any prior knowledge of the chemistry. We show the RSI correlates with reactivity and is able to search chemical space using the most reactive pathways.
An autonomous organic reaction search engine for chemical reactivity
NASA Astrophysics Data System (ADS)
Dragone, Vincenza; Sans, Victor; Henson, Alon B.; Granda, Jaroslaw M.; Cronin, Leroy
2017-06-01
The exploration of chemical space for new reactivity, reactions and molecules is limited by the need for separate work-up-separation steps searching for molecules rather than reactivity. Herein we present a system that can autonomously evaluate chemical reactivity within a network of 64 possible reaction combinations and aims for new reactivity, rather than a predefined set of targets. The robotic system combines chemical handling, in-line spectroscopy and real-time feedback and analysis with an algorithm that is able to distinguish and select the most reactive pathways, generating a reaction selection index (RSI) without need for separate work-up or purification steps. This allows the automatic navigation of a chemical network, leading to previously unreported molecules while needing only to do a fraction of the total possible reactions without any prior knowledge of the chemistry. We show the RSI correlates with reactivity and is able to search chemical space using the most reactive pathways.
An autonomous organic reaction search engine for chemical reactivity
Dragone, Vincenza; Sans, Victor; Henson, Alon B.; Granda, Jaroslaw M.; Cronin, Leroy
2017-01-01
The exploration of chemical space for new reactivity, reactions and molecules is limited by the need for separate work-up-separation steps searching for molecules rather than reactivity. Herein we present a system that can autonomously evaluate chemical reactivity within a network of 64 possible reaction combinations and aims for new reactivity, rather than a predefined set of targets. The robotic system combines chemical handling, in-line spectroscopy and real-time feedback and analysis with an algorithm that is able to distinguish and select the most reactive pathways, generating a reaction selection index (RSI) without need for separate work-up or purification steps. This allows the automatic navigation of a chemical network, leading to previously unreported molecules while needing only to do a fraction of the total possible reactions without any prior knowledge of the chemistry. We show the RSI correlates with reactivity and is able to search chemical space using the most reactive pathways. PMID:28598440
Real Time Voltage and Current Phase Shift Analyzer for Power Saving Applications
Krejcar, Ondrej; Frischer, Robert
2012-01-01
Nowadays, high importance is given to low energy devices (such as refrigerators, deep-freezers, washing machines, pumps, etc.) that are able to produce reactive power in power lines which can be optimized (reduced). Reactive power is the main component which overloads power lines and brings excessive thermal stress to conductors. If the reactive power is optimized, it can significantly lower the electricity consumption (from 10 to 30%—varies between countries). This paper will examine and discuss the development of a measuring device for analyzing reactive power. However, the main problem is the precise real time measurement of the input and output voltage and current. Such quality measurement is needed to allow adequate action intervention (feedback which reduces or fully compensates reactive power). Several other issues, such as the accuracy and measurement speed, must be examined while designing this device. The price and the size of the final product need to remain low as they are the two important parameters of this solution. PMID:23112662
Core-power and decay-time limits for disabled automatic-actuation of LOFT ECCS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanson, G.H.
1978-11-22
The Emergency Core Cooling System (ECCS) for the LOFT reactor may need to be disabled for modifications or repairs of hardware or instrumentation or for component testing during periods when the reactor system is hot and pressurized, or it may be desirable to enable the ECCS to be disabled without the necessity of cooling down and depressurizing the reactor. A policy involves disabling the automatic-actuation of the LOFT ECCS, but still retaining the manual actuation capability. Disabling of the automatic actuation can be safely utilized, without subjecting the fuel cladding to unacceptable temperatures, when the LOFT power decays to 33more » kW; this power level permits a maximum delay of 20 minutes following a LOCA for the manual actuation of ECCS. For the operating power of the L2-2 Experiment, the required decay-periods (with operating periods of 40 and 2000 hours) are about 21 and 389 hours, respectively. With operating periods of 40 and 2000 hours at Core-I full power, the required decay-periods are about 42 and 973 hours, respectively. After these decay periods the automatic actuation of the LOFT ECCS can be disabled assuming a maximum delay of 20 minutes following a LOCA for the manual actuation of ECCS. The automatic and manual lineup of the ECCS may be waived if decay power is less than 11 kW.« less
47 CFR 80.80 - Operating controls for ship stations.
Code of Federal Regulations, 2010 CFR
2010-10-01
...-162 MHz bands, reducing power output to one watt or less in accordance with § 80.215(e). 1 1 Ship... automatically reduce the carrier power to one watt or less when turned to the frequency 156.375 MHz or 156.650..., 1997, must automatically reduce power as described above. A manual override device must be provided...
Frequency control of wind turbine in power system
NASA Astrophysics Data System (ADS)
Xu, Huawei
2018-06-01
In order to improve the stability of the overall frequency of the power system, automatic power generation control and secondary frequency adjustment were applied. Automatic power generation control was introduced into power generation planning. A dual-fed wind generator power regulation model suitable for secondary frequency regulation was established. The results showed that this method satisfied the basic requirements of frequency regulation control of large-scale wind power access power systems and improved the stability and reliability of power system operation. Therefore, this system frequency control method and strategy is relatively simple. The effect is significant. The system frequency can quickly reach a steady state. It is worth applying and promoting.
Hareli, Shlomo; David, Shlomo
2017-06-01
Social perception of emotions is influenced by the context in which it occurs. One such context is a social interaction involving an exchange of emotions. The way parties to the interaction are perceived is shaped by the combination of emotions exchanged. This idea was examined by assessing the extent to which expressions of anger toward a target-which, in isolation, are perceived as signals of high social power-are influenced by the target's emotional reaction to it (i.e., reactive emotions). Three studies show that the angry person was perceived as having a higher level of social power when this anger was responded by fear or sadness than when it was responded by neutrality or anger. Study 1 indicated that reactive emotions have a stronger effect on perceived social power when emotions were incongruent with gender stereotypes. Study 2 indicated that these effects are a result of these emotions serving as reactive emotions rather than a benchmark against which the angry person's power is assessed. Study 3 showed that reactive emotions affect perceived social power by serving as signals of the level to which the high social power suggested by the first person's expression is confirmed by its target. Comparing effects of reactive emotions to anger with reactive emotions to sadness, showed that perceived social power of the expresser is determined by the nature of the expression, with some adjustment caused by the reactive emotions. This underscores the importance of social interaction as a context for the social perception of emotions. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
30 CFR 75.1403-4 - Criteria-Automatic elevators.
Code of Federal Regulations, 2010 CFR
2010-07-01
... appropriate on automatic elevators which will automatically shut-off the power and apply the brakes in the... telephone or other effective communication system by which aid or assistance can be obtained promptly. ...
El-Sharkawi, Mohamed A.; Venkata, Subrahmanyam S.; Chen, Mingliang; Andexler, George; Huang, Tony
1992-01-01
A system and method for determining and providing reactive power compensation for an inductive load. A reactive power compensator (50,50') monitors the voltage and current flowing through each of three distribution lines (52a, 52b, 52c), which are supplying three-phase power to one or more inductive loads. Using signals indicative of the current on each of these lines when the voltage waveform on the line crosses zero, the reactive power compensator determines a reactive power compensator capacitance that must be connected to the lines to maintain a desired VAR level, power factor, or line voltage. Alternatively, an operator can manually select a specific capacitance for connection to each line, or the capacitance can be selected based on a time schedule. The reactive power compensator produces control signals, which are coupled through optical fibers (102/106) to a switch driver (110, 110') to select specific compensation capacitors (112) for connections to each line. The switch driver develops triggering signals that are supplied to a plurality of series-connected solid state switches (350), which control charge current in one direction in respect to ground for each compensation capacitor. During each cycle, current flows from ground to charge the capacitors as the voltage on the line begins to go negative from its positive peak value. The triggering signals are applied to gate the solid state switches into a conducting state when the potential on the lines and on the capacitors reaches a negative peak value, thereby minimizing both the potential difference and across the charge current through the switches when they begin to conduct. Any harmonic distortion on the potential and current carried by the lines is filtered out from the current and potential signals used by the reactive power compensator so that it does not affect the determination of the required reactive compensation.
El-Sharkawi, M.A.; Venkata, S.S.; Chen, M.; Andexler, G.; Huang, T.
1992-07-28
A system and method for determining and providing reactive power compensation for an inductive load. A reactive power compensator (50,50') monitors the voltage and current flowing through each of three distribution lines (52a, 52b, 52c), which are supplying three-phase power to one or more inductive loads. Using signals indicative of the current on each of these lines when the voltage waveform on the line crosses zero, the reactive power compensator determines a reactive power compensator capacitance that must be connected to the lines to maintain a desired VAR level, power factor, or line voltage. Alternatively, an operator can manually select a specific capacitance for connection to each line, or the capacitance can be selected based on a time schedule. The reactive power compensator produces control signals, which are coupled through optical fibers (102/106) to a switch driver (110, 110') to select specific compensation capacitors (112) for connections to each line. The switch driver develops triggering signals that are supplied to a plurality of series-connected solid state switches (350), which control charge current in one direction in respect to ground for each compensation capacitor. During each cycle, current flows from ground to charge the capacitors as the voltage on the line begins to go negative from its positive peak value. The triggering signals are applied to gate the solid state switches into a conducting state when the potential on the lines and on the capacitors reaches a negative peak value, thereby minimizing both the potential difference and across the charge current through the switches when they begin to conduct. Any harmonic distortion on the potential and current carried by the lines is filtered out from the current and potential signals used by the reactive power compensator so that it does not affect the determination of the required reactive compensation. 26 figs.
NASA Astrophysics Data System (ADS)
Wang, Wu; Huang, Wei; Zhang, Yongjun
2018-03-01
The grid-integration of Photovoltaic-Storage System brings some undefined factors to the network. In order to make full use of the adjusting ability of Photovoltaic-Storage System (PSS), this paper puts forward a reactive power optimization model, which are used to construct the objective function based on power loss and the device adjusting cost, including energy storage adjusting cost. By using Cataclysmic Genetic Algorithm to solve this optimization problem, and comparing with other optimization method, the result proved that: the method of dynamic extended reactive power optimization this article puts forward, can enhance the effect of reactive power optimization, including reducing power loss and device adjusting cost, meanwhile, it gives consideration to the safety of voltage.
Review of Reactive Power Dispatch Strategies for Loss Minimization in a DFIG-based Wind Farm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Baohua; Hu, Weihao; Hou, Peng
This study reviews and compares the performance of reactive power dispatch strategies for the loss minimization of Doubly Fed Induction Generator (DFIG)-based Wind Farms (WFs). Twelve possible combinations of three WF level reactive power dispatch strategies and four Wind Turbine (WT) level reactive power control strategies are investigated. All of the combined strategies are formulated based on the comprehensive loss models of WFs, including the loss models of DFIGs, converters, filters, transformers, and cables of the collection system. Optimization problems are solved by a Modified Particle Swarm Optimization (MPSO) algorithm. The effectiveness of these strategies is evaluated by simulations onmore » a carefully designed WF under a series of cases with different wind speeds and reactive power requirements of the WF. The wind speed at each WT inside the WF is calculated using the Jensen wake model. The results show that the best reactive power dispatch strategy for loss minimization comes when the WF level strategy and WT level control are coordinated and the losses from each device in the WF are considered in the objective.« less
Review of Reactive Power Dispatch Strategies for Loss Minimization in a DFIG-based Wind Farm
Zhang, Baohua; Hu, Weihao; Hou, Peng; ...
2017-06-27
This study reviews and compares the performance of reactive power dispatch strategies for the loss minimization of Doubly Fed Induction Generator (DFIG)-based Wind Farms (WFs). Twelve possible combinations of three WF level reactive power dispatch strategies and four Wind Turbine (WT) level reactive power control strategies are investigated. All of the combined strategies are formulated based on the comprehensive loss models of WFs, including the loss models of DFIGs, converters, filters, transformers, and cables of the collection system. Optimization problems are solved by a Modified Particle Swarm Optimization (MPSO) algorithm. The effectiveness of these strategies is evaluated by simulations onmore » a carefully designed WF under a series of cases with different wind speeds and reactive power requirements of the WF. The wind speed at each WT inside the WF is calculated using the Jensen wake model. The results show that the best reactive power dispatch strategy for loss minimization comes when the WF level strategy and WT level control are coordinated and the losses from each device in the WF are considered in the objective.« less
NASA Astrophysics Data System (ADS)
Prakash, S.; Sinha, S. K.
2015-09-01
In this research work, two areas hydro-thermal power system connected through tie-lines is considered. The perturbation of frequencies at the areas and resulting tie line power flows arise due to unpredictable load variations that cause mismatch between the generated and demanded powers. Due to rising and falling power demand, the real and reactive power balance is harmed; hence frequency and voltage get deviated from nominal value. This necessitates designing of an accurate and fast controller to maintain the system parameters at nominal value. The main purpose of system generation control is to balance the system generation against the load and losses so that the desired frequency and power interchange between neighboring systems are maintained. The intelligent controllers like fuzzy logic, artificial neural network (ANN) and hybrid fuzzy neural network approaches are used for automatic generation control for the two area interconnected power systems. Area 1 consists of thermal reheat power plant whereas area 2 consists of hydro power plant with electric governor. Performance evaluation is carried out by using intelligent (ANFIS, ANN and fuzzy) control and conventional PI and PID control approaches. To enhance the performance of controller sliding surface i.e. variable structure control is included. The model of interconnected power system has been developed with all five types of said controllers and simulated using MATLAB/SIMULINK package. The performance of the intelligent controllers has been compared with the conventional PI and PID controllers for the interconnected power system. A comparison of ANFIS, ANN, Fuzzy and PI, PID based approaches shows the superiority of proposed ANFIS over ANN, fuzzy and PI, PID. Thus the hybrid fuzzy neural network controller has better dynamic response i.e., quick in operation, reduced error magnitude and minimized frequency transients.
Input Power Characteristics of a Three-Phase Thyristor Converter
DOT National Transportation Integrated Search
1973-10-01
A phase delay rectifier operating into a passive resistive load was instrumented in the laboratory. Techniques for accurate measurement of power, displacement reactive power, harmonic components, and distortion reactive power are presented. The chara...
Hannan, Mahammad A.; Hussein, Hussein A.; Mutashar, Saad; Samad, Salina A.; Hussain, Aini
2014-01-01
With the development of communication technologies, the use of wireless systems in biomedical implanted devices has become very useful. Bio-implantable devices are electronic devices which are used for treatment and monitoring brain implants, pacemakers, cochlear implants, retinal implants and so on. The inductive coupling link is used to transmit power and data between the primary and secondary sides of the biomedical implanted system, in which efficient power amplifier is very much needed to ensure the best data transmission rates and low power losses. However, the efficiency of the implanted devices depends on the circuit design, controller, load variation, changes of radio frequency coil's mutual displacement and coupling coefficients. This paper provides a comprehensive survey on various power amplifier classes and their characteristics, efficiency and controller techniques that have been used in bio-implants. The automatic frequency controller used in biomedical implants such as gate drive switching control, closed loop power control, voltage controlled oscillator, capacitor control and microcontroller frequency control have been explained. Most of these techniques keep the resonance frequency stable in transcutaneous power transfer between the external coil and the coil implanted inside the body. Detailed information including carrier frequency, power efficiency, coils displacement, power consumption, supplied voltage and CMOS chip for the controllers techniques are investigated and summarized in the provided tables. From the rigorous review, it is observed that the existing automatic frequency controller technologies are more or less can capable of performing well in the implant devices; however, the systems are still not up to the mark. Accordingly, current challenges and problems of the typical automatic frequency controller techniques for power amplifiers are illustrated, with a brief suggestions and discussion section concerning the progress of implanted device research in the future. This review will hopefully lead to increasing efforts towards the development of low powered, highly efficient, high data rate and reliable automatic frequency controllers for implanted devices. PMID:25615728
A Multi-agent Based Cooperative Voltage and Reactive Power Control
NASA Astrophysics Data System (ADS)
Ishida, Masato; Nagata, Takeshi; Saiki, Hiroshi; Shimada, Ikuhiko; Hatano, Ryousuke
In order to maintain system voltage within the optimal range and prevent voltage instability phenomena before they occur, a variety of phase modifying equipment is installed in optimal locations throughout the power system network and a variety of methods of voltage reactive control are employed. The proposed system divided the traditional method to control voltage and reactive power into two sub problems; “voltage control” to adjust the secondary bus voltage of substations, and “reactive power control” to adjust the primary bus voltage. In this system, two types of agents are installed in substations in order to cooperate “voltage control” and “reactive power control”. In order to verify the performance of the proposed method, it has been applied to the model network system. The results confirm that our proposed method is able to control violent fluctuations in load.
Automatic detection of electric power troubles (AI application)
NASA Technical Reports Server (NTRS)
Wang, Caroline; Zeanah, Hugh; Anderson, Audie; Patrick, Clint
1987-01-01
The design goals for the Automatic Detection of Electric Power Troubles (ADEPT) were to enhance Fault Diagnosis Techniques in a very efficient way. ADEPT system was designed in two modes of operation: (1) Real time fault isolation, and (2) a local simulator which simulates the models theoretically.
14 CFR 29.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Control Systems § 29.672 Stability augmentation, automatic, and power-operated systems. If the... unsafe condition if the pilot is unaware of the failure. Warning systems must not activate the control...
14 CFR 27.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.672 Stability augmentation, automatic, and power-operated systems. If the... unsafe condition if the pilot is unaware of the failure. Warning systems must not activate the control...
Multiple-Nozzle Spray Head Applies Foam Insulation
NASA Technical Reports Server (NTRS)
Walls, Joe T.
1993-01-01
Spray head equipped with four-nozzle turret mixes two reactive components of polyurethane and polyisocyanurate foam insulating material and sprays reacting mixture onto surface to be insulated. If nozzle in use becomes clogged, fresh one automatically rotated into position, with minimal interruption of spraying process. Incorporates features recirculating and controlling pressures of reactive components to maintain quality of foam by ensuring proper blend at outset. Also used to spray protective coats on or in ships, aircraft, and pipelines. Sprays such reactive adhesives as epoxy/polyurethane mixtures. Components of spray contain solid-particle fillers for strength, fire retardance, toughness, resistance to abrasion, or radar absorption.
Automatic control of solar power plants
NASA Astrophysics Data System (ADS)
Ermakov, V. S.; Dubilovich, V. M.
1982-02-01
The automatic control of the heliostat field of a 200-MW solar power plant is discussed. The advantages of the decentralized control principle with the solution of a number of individual problems in a single control center are emphasized. The basic requirements on heliostat construction are examined, and possible functional schemes for the automatic control of a heliostat field are described. It is proposed that groups of heliostats can be controlled from a single center and on the basis of a single algorithm.
Usman, Yasir; Kim, Jinho; Muljadi, Eduard; ...
2016-01-01
Wake effects cause wind turbine generators (WTGs) within a wind power plant (WPP) to produce different levels of active power and subsequent reactive power capabilities. Further, the impedance between a WTG and the point of interconnection (POI)-which depends on the distance between them-impacts the WPP's reactive power injection capability at the POI. This paper proposes a voltage control scheme for a WPP based on the available reactive current of the doubly-fed induction generators (DFIGs) and its impacts on the POI to improve the reactive power injection capability of the WPP. In this paper, a design strategy for modifying the gainmore » of DFIG controller is suggested and the comprehensive properties of these control gains are investigated. In the proposed scheme, the WPP controller, which operates in a voltage control mode, sends the command signal to the DFIGs based on the voltage difference at the POI. The DFIG controllers, which operate in a voltage control mode, employ a proportional controller with a limiter. The gain of the proportional controller is adjusted depending on the available reactive current of the DFIG and the series impedance between the DFIG and the POI. The performance of the proposed scheme is validated for various disturbances such as a reactive load connection and grid fault using an EMTP-RV simulator. Furthermore, simulation results demonstrate that the proposed scheme promptly recovers the POI voltage by injecting more reactive power after a disturbance than the conventional scheme.« less
14 CFR 25.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.672 Stability augmentation and automatic and power-operated systems. If the... the pilot were not aware of the failure. Warning systems must not activate the control systems. (b...
14 CFR 25.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.672 Stability augmentation and automatic and power-operated systems. If the... the pilot were not aware of the failure. Warning systems must not activate the control systems. (b...
14 CFR 25.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.672 Stability augmentation and automatic and power-operated systems. If the... the pilot were not aware of the failure. Warning systems must not activate the control systems. (b...
14 CFR 25.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.672 Stability augmentation and automatic and power-operated systems. If the... the pilot were not aware of the failure. Warning systems must not activate the control systems. (b...
Automatic-Control System for Safer Brazing
NASA Technical Reports Server (NTRS)
Stein, J. A.; Vanasse, M. A.
1986-01-01
Automatic-control system for radio-frequency (RF) induction brazing of metal tubing reduces probability of operator errors, increases safety, and ensures high-quality brazed joints. Unit combines functions of gas control and electric-power control. Minimizes unnecessary flow of argon gas into work area and prevents electrical shocks from RF terminals. Controller will not allow power to flow from RF generator to brazing head unless work has been firmly attached to head and has actuated micro-switch. Potential shock hazard eliminated. Flow of argon for purging and cooling must be turned on and adjusted before brazing power applied. Provision ensures power not applied prematurely, causing damaged work or poor-quality joints. Controller automatically turns off argon flow at conclusion of brazing so potentially suffocating gas does not accumulate in confined areas.
Hierarchical Control Scheme for Improving Transient Voltage Recovery of a DFIG-Based WPP
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jinho; Muljadi, Eduard; Kang, Yong Cheol
Modern grid codes require that wind power plants (WPPs) inject reactive power according to the voltage dip at a point of interconnection (POI). This requirement helps to support a POI voltage during a fault. However, if a fault is cleared, the POI and wind turbine generator (WTG) voltages are likely to exceed acceptable levels unless the WPP reduces the injected reactive power quickly. This might deteriorate the stability of a grid by allowing the disconnection of WTGs to avoid any damage. This paper proposes a hierarchical control scheme of a doubly-fed induction generator (DFIG)-based WPP. The proposed scheme aims tomore » improve the reactive power injecting capability during the fault and suppress the overvoltage after the fault clearance. To achieve the former, an adaptive reactive power-to-voltage scheme is implemented in each DFIG controller so that a DFIG with a larger reactive power capability will inject more reactive power. To achieve the latter, a washout filter is used to capture a high frequency component contained in the WPP voltage, which is used to remove the accumulated values in the proportional-integral controllers. Test results indicate that the scheme successfully supports the grid voltage during the fault, and recovers WPP voltages without exceeding the limit after the fault clearance.« less
Controlled cooling of an electronic system for reduced energy consumption
DOE Office of Scientific and Technical Information (OSTI.GOV)
David, Milnes P.; Iyengar, Madhusudan K.; Schmidt, Roger R.
Energy efficient control of a cooling system cooling an electronic system is provided. The control includes automatically determining at least one adjusted control setting for at least one adjustable cooling component of a cooling system cooling the electronic system. The automatically determining is based, at least in part, on power being consumed by the cooling system and temperature of a heat sink to which heat extracted by the cooling system is rejected. The automatically determining operates to reduce power consumption of the cooling system and/or the electronic system while ensuring that at least one targeted temperature associated with the coolingmore » system or the electronic system is within a desired range. The automatically determining may be based, at least in part, on one or more experimentally obtained models relating the targeted temperature and power consumption of the one or more adjustable cooling components of the cooling system.« less
Controlled cooling of an electronic system based on projected conditions
David, Milnes P.; Iyengar, Madhusudan K.; Schmidt, Roger R.
2016-05-17
Energy efficient control of a cooling system cooling an electronic system is provided based, in part, on projected conditions. The control includes automatically determining an adjusted control setting(s) for an adjustable cooling component(s) of the cooling system. The automatically determining is based, at least in part, on projected power consumed by the electronic system at a future time and projected temperature at the future time of a heat sink to which heat extracted is rejected. The automatically determining operates to reduce power consumption of the cooling system and/or the electronic system while ensuring that at least one targeted temperature associated with the cooling system or the electronic system is within a desired range. The automatically determining may be based, at least in part, on an experimentally obtained model(s) relating the targeted temperature and power consumption of the adjustable cooling component(s) of the cooling system.
Controlled cooling of an electronic system based on projected conditions
David, Milnes P.; Iyengar, Madhusudan K.; Schmidt, Roger R.
2015-08-18
Energy efficient control of a cooling system cooling an electronic system is provided based, in part, on projected conditions. The control includes automatically determining an adjusted control setting(s) for an adjustable cooling component(s) of the cooling system. The automatically determining is based, at least in part, on projected power consumed by the electronic system at a future time and projected temperature at the future time of a heat sink to which heat extracted is rejected. The automatically determining operates to reduce power consumption of the cooling system and/or the electronic system while ensuring that at least one targeted temperature associated with the cooling system or the electronic system is within a desired range. The automatically determining may be based, at least in part, on an experimentally obtained model(s) relating the targeted temperature and power consumption of the adjustable cooling component(s) of the cooling system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
David, Milnes P.; Iyengar, Madhusudan K.; Schmidt, Roger R.
Energy efficient control of a cooling system cooling an electronic system is provided. The control includes automatically determining at least one adjusted control setting for at least one adjustable cooling component of a cooling system cooling the electronic system. The automatically determining is based, at least in part, on power being consumed by the cooling system and temperature of a heat sink to which heat extracted by the cooling system is rejected. The automatically determining operates to reduce power consumption of the cooling system and/or the electronic system while ensuring that at least one targeted temperature associated with the coolingmore » system or the electronic system is within a desired range. The automatically determining may be based, at least in part, on one or more experimentally obtained models relating the targeted temperature and power consumption of the one or more adjustable cooling components of the cooling system.« less
Automatic Detection of Electric Power Troubles (ADEPT)
NASA Technical Reports Server (NTRS)
Wang, Caroline; Zeanah, Hugh; Anderson, Audie; Patrick, Clint; Brady, Mike; Ford, Donnie
1988-01-01
Automatic Detection of Electric Power Troubles (A DEPT) is an expert system that integrates knowledge from three different suppliers to offer an advanced fault-detection system. It is designed for two modes of operation: real time fault isolation and simulated modeling. Real time fault isolation of components is accomplished on a power system breadboard through the Fault Isolation Expert System (FIES II) interface with a rule system developed in-house. Faults are quickly detected and displayed and the rules and chain of reasoning optionally provided on a laser printer. This system consists of a simulated space station power module using direct-current power supplies for solar arrays on three power buses. For tests of the system's ablilty to locate faults inserted via switches, loads are configured by an INTEL microcomputer and the Symbolics artificial intelligence development system. As these loads are resistive in nature, Ohm's Law is used as the basis for rules by which faults are located. The three-bus system can correct faults automatically where there is a surplus of power available on any of the three buses. Techniques developed and used can be applied readily to other control systems requiring rapid intelligent decisions. Simulated modeling, used for theoretical studies, is implemented using a modified version of Kennedy Space Center's KATE (Knowledge-Based Automatic Test Equipment), FIES II windowing, and an ADEPT knowledge base.
Automatic Detection of Electric Power Troubles (ADEPT)
NASA Astrophysics Data System (ADS)
Wang, Caroline; Zeanah, Hugh; Anderson, Audie; Patrick, Clint; Brady, Mike; Ford, Donnie
1988-11-01
Automatic Detection of Electric Power Troubles (A DEPT) is an expert system that integrates knowledge from three different suppliers to offer an advanced fault-detection system. It is designed for two modes of operation: real time fault isolation and simulated modeling. Real time fault isolation of components is accomplished on a power system breadboard through the Fault Isolation Expert System (FIES II) interface with a rule system developed in-house. Faults are quickly detected and displayed and the rules and chain of reasoning optionally provided on a laser printer. This system consists of a simulated space station power module using direct-current power supplies for solar arrays on three power buses. For tests of the system's ablilty to locate faults inserted via switches, loads are configured by an INTEL microcomputer and the Symbolics artificial intelligence development system. As these loads are resistive in nature, Ohm's Law is used as the basis for rules by which faults are located. The three-bus system can correct faults automatically where there is a surplus of power available on any of the three buses. Techniques developed and used can be applied readily to other control systems requiring rapid intelligent decisions. Simulated modeling, used for theoretical studies, is implemented using a modified version of Kennedy Space Center's KATE (Knowledge-Based Automatic Test Equipment), FIES II windowing, and an ADEPT knowledge base.
Automatic emotion processing as a function of trait emotional awareness: an fMRI study
Lichev, Vladimir; Sacher, Julia; Ihme, Klas; Rosenberg, Nicole; Quirin, Markus; Lepsien, Jöran; Pampel, André; Rufer, Michael; Grabe, Hans-Jörgen; Kugel, Harald; Kersting, Anette; Villringer, Arno; Lane, Richard D.
2015-01-01
It is unclear whether reflective awareness of emotions is related to extent and intensity of implicit affective reactions. This study is the first to investigate automatic brain reactivity to emotional stimuli as a function of trait emotional awareness. To assess emotional awareness the Levels of Emotional Awareness Scale (LEAS) was administered. During scanning, masked happy, angry, fearful and neutral facial expressions were presented to 46 healthy subjects, who had to rate the fit between artificial and emotional words. The rating procedure allowed assessment of shifts in implicit affectivity due to emotion faces. Trait emotional awareness was associated with increased activation in the primary somatosensory cortex, inferior parietal lobule, anterior cingulate gyrus, middle frontal and cerebellar areas, thalamus, putamen and amygdala in response to masked happy faces. LEAS correlated positively with shifts in implicit affect caused by masked happy faces. According to our findings, people with high emotional awareness show stronger affective reactivity and more activation in brain areas involved in emotion processing and simulation during the perception of masked happy facial expression than people with low emotional awareness. High emotional awareness appears to be characterized by an enhanced positive affective resonance to others at an automatic processing level. PMID:25140051
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smed, T.; Andersson, G.
In this paper, damping of slow oscillations with active and reactive power modulation of HVDC-links is analyzed with the aim of gaining a physical insight into the problem. The analysis shows that active power modulation is efficient when applied to a short mass-scaled electrical distance from one of the swinging machines, and reactive power modulation is most efficient when there exists a well-defined power flow direction and the modulation is made at a point close to the electrical midpoint between the swinging machines. It is shown that the intuitively appealing feedback signals frequency and derivative of the voltage are appropriatemore » for active and reactive power modulation, respectively. The impact of the constraints imposed by the HVDC equations are analyzed, and it is determined when the implicit reactive power modulation resulting from constant [gamma] control may be detrimental for the damping.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Usman, Yasir; Kim, Jinho; Muljadi, Eduard
Wake effects cause wind turbine generators (WTGs) within a wind power plant (WPP) to produce different levels of active power and subsequent reactive power capabilities. Further, the impedance between a WTG and the point of interconnection (POI)-which depends on the distance between them-impacts the WPP's reactive power injection capability at the POI. This paper proposes a voltage control scheme for a WPP based on the available reactive current of the doubly-fed induction generators (DFIGs) and its impacts on the POI to improve the reactive power injection capability of the WPP. In this paper, a design strategy for modifying the gainmore » of DFIG controller is suggested and the comprehensive properties of these control gains are investigated. In the proposed scheme, the WPP controller, which operates in a voltage control mode, sends the command signal to the DFIGs based on the voltage difference at the POI. The DFIG controllers, which operate in a voltage control mode, employ a proportional controller with a limiter. The gain of the proportional controller is adjusted depending on the available reactive current of the DFIG and the series impedance between the DFIG and the POI. The performance of the proposed scheme is validated for various disturbances such as a reactive load connection and grid fault using an EMTP-RV simulator. Furthermore, simulation results demonstrate that the proposed scheme promptly recovers the POI voltage by injecting more reactive power after a disturbance than the conventional scheme.« less
46 CFR 161.002-9 - Automatic fire detecting system, power supply.
Code of Federal Regulations, 2013 CFR
2013-10-01
... system must meet the requirements of § 113.10-9 of subchapter J (Electrical Engineering Regulations) of... 46 Shipping 6 2013-10-01 2013-10-01 false Automatic fire detecting system, power supply. 161.002-9..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL ELECTRICAL EQUIPMENT Fire-Protective Systems § 161.002...
46 CFR 161.002-9 - Automatic fire detecting system, power supply.
Code of Federal Regulations, 2014 CFR
2014-10-01
... system must meet the requirements of § 113.10-9 of subchapter J (Electrical Engineering Regulations) of... 46 Shipping 6 2014-10-01 2014-10-01 false Automatic fire detecting system, power supply. 161.002-9..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL ELECTRICAL EQUIPMENT Fire-Protective Systems § 161.002...
46 CFR 161.002-9 - Automatic fire detecting system, power supply.
Code of Federal Regulations, 2012 CFR
2012-10-01
... system must meet the requirements of § 113.10-9 of subchapter J (Electrical Engineering Regulations) of... 46 Shipping 6 2012-10-01 2012-10-01 false Automatic fire detecting system, power supply. 161.002-9..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL ELECTRICAL EQUIPMENT Fire-Protective Systems § 161.002...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-02
... automatic reversal systems (ARS) for power windows and to make a final decision. The agency has decided not... requirements for automatic reversal systems (ARS) and are withdrawing our 2009 proposal regarding ARS. This... of proposed rulemaking (NPRM) proposing new requirements for ARS. The proposal discussed the agency's...
Broadband and High power Reactive Jamming Resilient Wireless Communication
2017-10-21
Broadband and High -power Reactive Jamming Resilient Wireless Communication The views, opinions and/or findings contained in this report are those of... available in extremely hostile environments, where FHSS and DSSS are completely defeated by a broadband and high -power reactive jammer. b. Wireless...SECURITY CLASSIFICATION OF: 1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 13. SUPPLEMENTARY NOTES 12. DISTRIBUTION AVAILIBILITY STATEMENT 6. AUTHORS
Analysis and Research on the effect of the Operation of Small Hydropower in the Regional Power Grid
NASA Astrophysics Data System (ADS)
Ang, Fu; Guangde, Dong; Xiaojun, Zhu; Ruimiao, Wang; Shengyi, Zhu
2018-03-01
The analysis of reactive power balance and voltage of power network not only affects the system voltage quality, but also affects the economic operation of power grid. In the calculation of reactive power balance and voltage analysis in the past, the problem of low power and low system voltage has been the concern of people. When small hydropower stations in the wet period of low load, the analysis of reactive power surplus and high voltage for the system, if small hydropower unit the capability of running in phase is considered, it can effectively solve the system low operation voltage of the key point on the high side.
Voltage droop Coordinating Control applied in UPFC and STATCOM system
NASA Astrophysics Data System (ADS)
Junhui, Huang; Zhuyi, Peng; Chengjie, Ni; Yiqing, Xu; Jiliang, Xue
2018-04-01
When UPFC, unified power flow controller is applied with other FACTS into power grid, it is possible that the voltage controlled vibrates constantly to response to a sudden reactive power turbulent in grid if the parameters of these FACTS are not coordinating reasonably. Moreover, the reactive power generated by these equipment will intertwine unexpectedly. The article proposes a method named voltage-reactive power droop control to allow the reference voltage fluctuating around the rating voltage so that the vibration is reduced and the power distribution is improved. Finally, the article cite a electric-magnetic simulation by EMTDC models of east-China power grid to prove it effective when applied to improve the response characteristics to sudden turbulence in power grid.
Development and evaluation of automatic landing control laws for power lift STOL aircraft
NASA Technical Reports Server (NTRS)
Feinreich, B.; Gevaert, G.
1981-01-01
A series of investigations were conducted to generate and verify through ground bases simulation and flight research a data base to aid in the design and certification of advanced propulsive lift short takeoff and landing aircraft. Problems impacting the design of powered lift short haul aircraft that are to be landed automatically on STOL runways in adverse weather were examined. An understanding of the problems was gained by a limited coverage of important elements that are normally included in the certification process of a CAT 3 automatic landing system.
NASA Astrophysics Data System (ADS)
Jin, N.; Yang, F.; Shang, S. Y.; Tao, T.; Liu, J. S.
2016-08-01
According to the limitations of the LVRT technology of traditional photovoltaic inverter existed, this paper proposes a low voltage ride through (LVRT) control method based on model current predictive control (MCPC). This method can effectively improve the photovoltaic inverter output characteristics and response speed. The MCPC method of photovoltaic grid-connected inverter designed, the sum of the absolute value of the predictive current and the given current error is adopted as the cost function with the model predictive control method. According to the MCPC, the optimal space voltage vector is selected. Photovoltaic inverter has achieved automatically switches of priority active or reactive power control of two control modes according to the different operating states, which effectively improve the inverter capability of LVRT. The simulation and experimental results proves that the proposed method is correct and effective.
Extremum Seeking Control of Smart Inverters for VAR Compensation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arnold, Daniel; Negrete-Pincetic, Matias; Stewart, Emma
2015-09-04
Reactive power compensation is used by utilities to ensure customer voltages are within pre-defined tolerances and reduce system resistive losses. While much attention has been paid to model-based control algorithms for reactive power support and Volt Var Optimization (VVO), these strategies typically require relatively large communications capabilities and accurate models. In this work, a non-model-based control strategy for smart inverters is considered for VAR compensation. An Extremum Seeking control algorithm is applied to modulate the reactive power output of inverters based on real power information from the feeder substation, without an explicit feeder model. Simulation results using utility demand informationmore » confirm the ability of the control algorithm to inject VARs to minimize feeder head real power consumption. In addition, we show that the algorithm is capable of improving feeder voltage profiles and reducing reactive power supplied by the distribution substation.« less
A DFIG Islanding Detection Scheme Based on Reactive Power Infusion
NASA Astrophysics Data System (ADS)
Wang, M.; Liu, C.; He, G. Q.; Li, G. H.; Feng, K. H.; Sun, W. W.
2017-07-01
A lot of research has been done on photovoltaic (the “PV”) power system islanding detection in recent years. As a comparison, much less attention has been paid to islanding in wind turbines. Meanwhile, wind turbines can work in islanding conditions for quite a long period, which can be harmful to equipments and cause safety hazards. This paper presents and examines a double fed introduction generation (the “DFIG”) islanding detection scheme based on feedback of reactive power and frequency and uses a trigger signal of reactive power infusion which can be obtained by dividing the voltage total harmonic distortion (the "THD") by the voltage THD of last cycle to avoid the deterioration of power quality. This DFIG islanding detection scheme uses feedback of reactive power current loop to amplify the frequency differences in islanding and normal conditions. Simulation results show that the DFIG islanding detection scheme is effective.
Memory traces of long-range coordinated oscillations in the sleeping human brain.
Piantoni, Giovanni; Van Der Werf, Ysbrand D; Jensen, Ole; Van Someren, Eus J W
2015-01-01
Cognition involves coordinated activity across distributed neuronal networks. Neuronal activity during learning triggers cortical plasticity that allows for reorganization of the neuronal network and integration of new information. Animal studies have shown post-learning reactivation of learning-elicited neuronal network activity during subsequent sleep, supporting consolidation of the reorganization. However, no previous studies, to our knowledge, have demonstrated reactivation of specific learning-elicited long-range functional connectivity during sleep in humans. We here show reactivation of learning-induced long-range synchronization of magnetoencephalography power fluctuations in human sleep. Visuomotor learning elicited a specific profile of long-range cortico-cortical synchronization of slow (0.1 Hz) fluctuations in beta band (12-30 Hz) power. The parieto-occipital part of this synchronization profile reappeared in delta band (1-3.5 Hz) power fluctuations during subsequent sleep, but not during the intervening wakefulness period. Individual differences in the reactivated synchronization predicted postsleep performance improvement. The presleep resting-state synchronization profile was not reactivated during sleep. The findings demonstrate reactivation of long-range coordination of neuronal activity in humans, more specifically of reactivation of coupling of infra-slow fluctuations in oscillatory power. The spatiotemporal profile of delta power fluctuations during sleep may subserve memory consolidation by echoing coordinated activation elicited by prior learning. © 2014 Wiley Periodicals, Inc.
Reactive power and voltage control strategy based on dynamic and adaptive segment for DG inverter
NASA Astrophysics Data System (ADS)
Zhai, Jianwei; Lin, Xiaoming; Zhang, Yongjun
2018-03-01
The inverter of distributed generation (DG) can support reactive power to help solve the problem of out-of-limit voltage in active distribution network (ADN). Therefore, a reactive voltage control strategy based on dynamic and adaptive segment for DG inverter is put forward to actively control voltage in this paper. The proposed strategy adjusts the segmented voltage threshold of Q(U) droop curve dynamically and adaptively according to the voltage of grid-connected point and the power direction of adjacent downstream line. And then the reactive power reference of DG inverter can be got through modified Q(U) control strategy. The reactive power of inverter is controlled to trace the reference value. The proposed control strategy can not only control the local voltage of grid-connected point but also help to maintain voltage within qualified range considering the terminal voltage of distribution feeder and the reactive support for adjacent downstream DG. The scheme using the proposed strategy is compared with the scheme without the reactive support of DG inverter and the scheme using the Q(U) control strategy with constant segmented voltage threshold. The simulation results suggest that the proposed method has a significant improvement on solving the problem of out-of-limit voltage, restraining voltage variation and improving voltage quality.
Autonomic Impairment in Severe Traumatic Brain Injury: A Multimodal Neuromonitoring Study.
Sykora, Marek; Czosnyka, Marek; Liu, Xiuyun; Donnelly, Joseph; Nasr, Nathalie; Diedler, Jennifer; Okoroafor, Francois; Hutchinson, Peter; Menon, David; Smielewski, Peter
2016-06-01
Autonomic impairment after acute traumatic brain injury has been associated independently with both increased morbidity and mortality. Links between autonomic impairment and increased intracranial pressure or impaired cerebral autoregulation have been described as well. However, relationships between autonomic impairment, intracranial pressure, impaired cerebral autoregulation, and outcome remain poorly explored. Using continuous measurements of heart rate variability and baroreflex sensitivity we aimed to test whether autonomic markers are associated with functional outcome and mortality independently of intracranial variables. Further, we aimed to evaluate the relationships between autonomic functions, intracranial pressure, and cerebral autoregulation. Retrospective analysis of a prospective database. Neurocritical care unit in a university hospital. Sedated patients with severe traumatic brain injury. Waveforms of intracranial pressure and arterial blood pressure, baseline Glasgow Coma Scale and 6 months Glasgow Outcome Scale were recorded. Baroreflex sensitivity was assessed every 10 seconds using a modified cross-correlational method. Frequency domain analyses of heart rate variability were performed automatically every 10 seconds from a moving 300 seconds of the monitoring time window. Mean values of baroreflex sensitivity, heart rate variability, intracranial pressure, arterial blood pressure, cerebral perfusion pressure, and impaired cerebral autoregulation over the entire monitoring period were calculated for each patient. Two hundred and sixty-two patients with a median age of 36 years entered the analysis. The median admission Glasgow Coma Scale was 6, the median Glasgow Outcome Scale was 3, and the mortality at 6 months was 23%. Baroreflex sensitivity (adjusted odds ratio, 0.9; p = 0.02) and relative power of a high frequency band of heart rate variability (adjusted odds ratio, 1.05; p < 0.001) were individually associated with mortality, independently of age, admission Glasgow Coma Scale, intracranial pressure, pressure reactivity index, or cerebral perfusion pressure. Baroreflex sensitivity showed no correlation with intracranial pressure or cerebral perfusion pressure; the correlation with pressure reactivity index was strong in older patients (age, > 60 yr). The relative power of high frequency correlated significantly with intracranial pressure and cerebral perfusion pressure, but not with pressure reactivity index. The relative power of low frequency correlated significantly with pressure reactivity index. Autonomic impairment, as measured by heart rate variability and baroreflex sensitivity, is significantly associated with increased mortality after traumatic brain injury. These effects, though partially interlinked, seem to be independent of age, trauma severity, intracranial pressure, or autoregulatory status, and thus represent a discrete phenomenon in the pathophysiology of traumatic brain injury. Continuous measurements of heart rate variability and baroreflex sensitivity in the neuromonitoring setting of severe traumatic brain injury may carry novel pathophysiological and predictive information.
An improved AVC strategy applied in distributed wind power system
NASA Astrophysics Data System (ADS)
Zhao, Y. N.; Liu, Q. H.; Song, S. Y.; Mao, W.
2016-08-01
Traditional AVC strategy is mainly used in wind farm and only concerns about grid connection point, which is not suitable for distributed wind power system. Therefore, this paper comes up with an improved AVC strategy applied in distributed wind power system. The strategy takes all nodes of distribution network into consideration and chooses the node having the most serious voltage deviation as control point to calculate the reactive power reference. In addition, distribution principles can be divided into two conditions: when wind generators access to network on single node, the reactive power reference is distributed according to reactive power capacity; when wind generators access to network on multi-node, the reference is distributed according to sensitivity. Simulation results show the correctness and reliability of the strategy. Compared with traditional control strategy, the strategy described in this paper can make full use of generators reactive power output ability according to the distribution network voltage condition and improve the distribution network voltage level effectively.
Water reactive hydrogen fuel cell power system
Wallace, Andrew P; Melack, John M; Lefenfeld, Michael
2014-01-21
A water reactive hydrogen fueled power system includes devices and methods to combine reactant fuel materials and aqueous solutions to generate hydrogen. The generated hydrogen is converted in a fuel cell to provide electricity. The water reactive hydrogen fueled power system includes a fuel cell, a water feed tray, and a fuel cartridge to generate power for portable power electronics. The removable fuel cartridge is encompassed by the water feed tray and fuel cell. The water feed tray is refillable with water by a user. The water is then transferred from the water feed tray into a fuel cartridge to generate hydrogen for the fuel cell which then produces power for the user.
Water reactive hydrogen fuel cell power system
Wallace, Andrew P; Melack, John M; Lefenfeld, Michael
2014-11-25
A water reactive hydrogen fueled power system includes devices and methods to combine reactant fuel materials and aqueous solutions to generate hydrogen. The generated hydrogen is converted in a fuel cell to provide electricity. The water reactive hydrogen fueled power system includes a fuel cell, a water feed tray, and a fuel cartridge to generate power for portable power electronics. The removable fuel cartridge is encompassed by the water feed tray and fuel cell. The water feed tray is refillable with water by a user. The water is then transferred from the water feed tray into the fuel cartridge to generate hydrogen for the fuel cell which then produces power for the user.
Core-power and decay-time limits for disabled automatic-actuation of LOFT ECCS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanson, G.H.
1978-06-05
The Emergency Core Cooling System (ECCS) for the LOFT reactor may need to be disabled for modifications or repairs of hardware or instrumentation or for component testing during periods when the reactor system is hot and pressurized, or it may be desirable to enable the ECCS to be disabled without the necessity of cooling down and depressurizing the reactor. LTR 113-47 has shown that the LOFT ECCS can be safely bypassed or disabled when the total core power does not exceed 25 kW. A modified policy involves disabling the automatic actuation of the LOFT ECCS, but still retaining the manualmore » activation capability. Disabling of the automatic actuation can be safely utilized, without subjecting the fuel cladding to unacceptable temperatures, when the LOFT power decays to 70 kW; this power level permits a maximum delay of 20 minutes following a LOCA for the manual actuation of ECCS.« less
Automatic Learning of Fine Operating Rules for Online Power System Security Control.
Sun, Hongbin; Zhao, Feng; Wang, Hao; Wang, Kang; Jiang, Weiyong; Guo, Qinglai; Zhang, Boming; Wehenkel, Louis
2016-08-01
Fine operating rules for security control and an automatic system for their online discovery were developed to adapt to the development of smart grids. The automatic system uses the real-time system state to determine critical flowgates, and then a continuation power flow-based security analysis is used to compute the initial transfer capability of critical flowgates. Next, the system applies the Monte Carlo simulations to expected short-term operating condition changes, feature selection, and a linear least squares fitting of the fine operating rules. The proposed system was validated both on an academic test system and on a provincial power system in China. The results indicated that the derived rules provide accuracy and good interpretability and are suitable for real-time power system security control. The use of high-performance computing systems enables these fine operating rules to be refreshed online every 15 min.
Power-based Shift Schedule for Pure Electric Vehicle with a Two-speed Automatic Transmission
NASA Astrophysics Data System (ADS)
Wang, Jiaqi; Liu, Yanfang; Liu, Qiang; Xu, Xiangyang
2016-11-01
This paper introduces a comprehensive shift schedule for a two-speed automatic transmission of pure electric vehicle. Considering about driving ability and efficiency performance of electric vehicles, the power-based shift schedule is proposed with three principles. This comprehensive shift schedule regards the vehicle current speed and motor load power as input parameters to satisfy the vehicle driving power demand with lowest energy consumption. A simulation model has been established to verify the dynamic and economic performance of comprehensive shift schedule. Compared with traditional dynamic and economic shift schedules, simulation results indicate that the power-based shift schedule is superior to traditional shift schedules.
Reactive power management and voltage control in deregulated power markets
NASA Astrophysics Data System (ADS)
Spangler, Robert G.
The research that is the subject of this dissertation is about the management of reactive power and voltage support in the wholesale open access power markets in the United States (US). The purpose of this research is to place decisions about open access market structures, as they relate to reactive power and voltage control, on a logical and consistent economic basis, given the engineering needs of a commercial electric power system. An examination of the electricity markets operating in the US today reveals that current approaches to reactive power management and voltage support are extensions of those based on historical, regulated monopoly electric service. A case for change is built by first looking at the subject of reactive power from an engineering viewpoint and then from an economic perspective. Ultimately, a set of market rules for managing reactive power and voltage support is proposed. The proposal suggests that cost recovery for static and dynamic VARs is appropriately accomplished through the regulated transmission cost of service. Static VAR cost recovery should follow traditional rate recovery methodologies. In the case of dynamic VARs, this work provides a methodology based on the microeconomic theory of the firm for determining such cost. It further suggests that an operational strategy that reduces and limits the use of dynamic VARs, during normal operations, is appropriate. This latter point leads to an increase in the fixed cost of the transmission network but prevents price spikes and short supply situations from affecting, or being affected by, the reactive capability limitations associated with dynamic VARs supplied from synchronous generators. The rules are consistent with a market structure that includes competitive generation and their application will result in the communication of a clear understanding of the responsibilities, related to voltage control, of each type of market entity. In this sense, their application will contribute to the efficient functioning of the wholesale open access markets.
Application of automatic image analysis in wood science
Charles W. McMillin
1982-01-01
In this paper I describe an image analysis system and illustrate with examples the application of automatic quantitative measurement to wood science. Automatic image analysis, a powerful and relatively new technology, uses optical, video, electronic, and computer components to rapidly derive information from images with minimal operator interaction. Such instruments...
NASA Astrophysics Data System (ADS)
Almasoudi, Fahad M.; Alatawi, Khaled S.; Matin, Mohammad
2017-08-01
Implementation of transformerless inverters in PV grid-tied system offer great benefits such as high efficiency, light weight, low cost, etc. Most of the proposed transformerless inverters in literature are verified for only real power application. Currently, international standards such as VDE-AR-N 4105 has demanded that PV grid-tied inverters should have the ability of controlling a specific amount of reactive power. Generation of reactive power cannot be accomplished in single phase transformerless inverter topologies because the existing modulation techniques are not adopted for a freewheeling path in the negative power region. This paper enhances a previous high efficiency proposed H6 trnasformerless inverter with SiC MOSFETs and demonstrates new operating modes for the generation of reactive power. A proposed pulse width modulation (PWM) technique is applied to achieve bidirectional current flow through freewheeling state. A comparison of the proposed H6 transformerless inverter using SiC MOSFETs and Si MOSFTEs is presented in terms of power losses and efficiency. The results show that reactive power control is attained without adding any additional active devices or modification to the inverter structure. Also, the proposed modulation maintains a constant common mode voltage (CM) during every operating mode and has low leakage current. The performance of the proposed system verifies its effectiveness in the next generation PV system.
2012-01-01
Background Ultrasonic scalpel (UC) and monopolar electrocautery (ME) are common tools for soft tissue dissection. However, morphological data on the related tissue alteration are discordant. We developed an automatic device for standardized sample excision and compared quality and depth of morphological changes caused by UC and ME in a pig model. Methods 100 tissue samples (5 × 3 cm) of the abdominal wall were excised in 16 pigs. Excisions were randomly performed manually or by using the self-constructed automatic device at standard power levels (60 W cutting in ME, level 5 in UC) for abdominal surgery. Quality of tissue alteration and depth of coagulation necrosis were examined histopathologically. Device (UC vs. ME) and mode (manually vs. automatic) effects were studied by two-way analysis of variance at a significance level of 5%. Results At the investigated power level settings UC and ME induced qualitatively similar coagulation necroses. Mean depth of necrosis was 450.4 ± 457.8 μm for manual UC and 553.5 ± 326.9 μm for automatic UC versus 149.0 ± 74.3 μm for manual ME and 257.6 ± 119.4 μm for automatic ME. Coagulation necrosis was significantly deeper (p < 0.01) when UC was used compared to ME. The mode of excision (manual versus automatic) did not influence the depth of necrosis (p = 0.85). There was no significant interaction between dissection tool and mode of excision (p = 0.93). Conclusions Thermal injury caused by UC and ME results in qualitatively similar coagulation necrosis. The depth of necrosis is significantly greater in UC compared to ME at investigated standard power levels. PMID:22361346
Homayounfar, Kia; Meis, Johanna; Jung, Klaus; Klosterhalfen, Bernd; Sprenger, Thilo; Conradi, Lena-Christin; Langer, Claus; Becker, Heinz
2012-02-23
Ultrasonic scalpel (UC) and monopolar electrocautery (ME) are common tools for soft tissue dissection. However, morphological data on the related tissue alteration are discordant. We developed an automatic device for standardized sample excision and compared quality and depth of morphological changes caused by UC and ME in a pig model. 100 tissue samples (5 × 3 cm) of the abdominal wall were excised in 16 pigs. Excisions were randomly performed manually or by using the self-constructed automatic device at standard power levels (60 W cutting in ME, level 5 in UC) for abdominal surgery. Quality of tissue alteration and depth of coagulation necrosis were examined histopathologically. Device (UC vs. ME) and mode (manually vs. automatic) effects were studied by two-way analysis of variance at a significance level of 5%. At the investigated power level settings UC and ME induced qualitatively similar coagulation necroses. Mean depth of necrosis was 450.4 ± 457.8 μm for manual UC and 553.5 ± 326.9 μm for automatic UC versus 149.0 ± 74.3 μm for manual ME and 257.6 ± 119.4 μm for automatic ME. Coagulation necrosis was significantly deeper (p < 0.01) when UC was used compared to ME. The mode of excision (manual versus automatic) did not influence the depth of necrosis (p = 0.85). There was no significant interaction between dissection tool and mode of excision (p = 0.93). Thermal injury caused by UC and ME results in qualitatively similar coagulation necrosis. The depth of necrosis is significantly greater in UC compared to ME at investigated standard power levels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sarrao, J.; Kwok, W-K; Bozovic, I.
As an energy carrier, electricity has no rival with regard to its environmental cleanliness, flexibility in interfacing with multiple production sources and end uses, and efficiency of delivery. In fact, the electric power grid was named ?the greatest engineering achievement of the 20th century? by the National Academy of Engineering. This grid, a technological marvel ingeniously knitted together from local networks growing out from cities and rural centers, may be the biggest and most complex artificial system ever built. However, the growing demand for electricity will soon challenge the grid beyond its capability, compromising its reliability through voltage fluctuations thatmore » crash digital electronics, brownouts that disable industrial processes and harm electrical equipment, and power failures like the North American blackout in 2003 and subsequent blackouts in London, Scandinavia, and Italy in the same year. The North American blackout affected 50 million people and caused approximately $6 billion in economic damage over the four days of its duration. Superconductivity offers powerful new opportunities for restoring the reliability of the power grid and increasing its capacity and efficiency. Superconductors are capable of carrying current without loss, making the parts of the grid they replace dramatically more efficient. Superconducting wires carry up to five times the current carried by copper wires that have the same cross section, thereby providing ample capacity for future expansion while requiring no increase in the number of overhead access lines or underground conduits. Their use is especially attractive in urban areas, where replacing copper with superconductors in power-saturated underground conduits avoids expensive new underground construction. Superconducting transformers cut the volume, weight, and losses of conventional transformers by a factor of two and do not require the contaminating and flammable transformer oils that violate urban safety codes. Unlike traditional grid technology, superconducting fault current limiters are smart. They increase their resistance abruptly in response to overcurrents from faults in the system, thus limiting the overcurrents and protecting the grid from damage. They react fast in both triggering and automatically resetting after the overload is cleared, providing a new, self-healing feature that enhances grid reliability. Superconducting reactive power regulators further enhance reliability by instantaneously adjusting reactive power for maximum efficiency and stability in a compact and economic package that is easily sited in urban grids. Not only do superconducting motors and generators cut losses, weight, and volume by a factor of two, but they are also much more tolerant of voltage sag, frequency instabilities, and reactive power fluctuations than their conventional counterparts. The challenge facing the electricity grid to provide abundant, reliable power will soon grow to crisis proportions. Continuing urbanization remains the dominant historic demographic trend in the United States and in the world. By 2030, nearly 90% of the U.S. population will reside in cities and suburbs, where increasingly strict permitting requirements preclude bringing in additional overhead access lines, underground cables are saturated, and growth in power demand is highest. The power grid has never faced a challenge so great or so critical to our future productivity, economic growth, and quality of life. Incremental advances in existing grid technology are not capable of solving the urban power bottleneck. Revolutionary new solutions are needed ? the kind that come only from superconductivity.« less
Power and energy ratios in mechanical CVT drive control
NASA Astrophysics Data System (ADS)
Balakin, P. D.; Stripling, L. O.
2017-06-01
Being based on the principle of providing the systems with adaptation property to the real parameters and operational condition, the mechanical system capable to control automatically the components of convertible power is offered and this allows providing stationary operation of the vehicle engine in the terms of variable external loading. This is achieved by drive control integrated in the power transmission, which implements an additional degree of freedom and operates on the basis of the laws of motion, with the energy of the main power flow by changing automatically the kinematic characteristics of the power transmission, this system being named CVT. The power and energy ratios found allow performing the necessary design calculations of the sections and the links of the mechanical CVT scheme.
12 CFR 7.1018 - Automatic payment plan account.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 12 Banks and Banking 1 2011-01-01 2011-01-01 false Automatic payment plan account. 7.1018 Section 7.1018 Banks and Banking COMPTROLLER OF THE CURRENCY, DEPARTMENT OF THE TREASURY BANK ACTIVITIES AND OPERATIONS Bank Powers § 7.1018 Automatic payment plan account. A national bank may, for the benefit and...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-20
... novel or unusual design feature associated with go-around performance credit for use of Automatic Power... docket in person, go to the address in the ADDRESSES section of this preamble between 7:30 a.m. and 4 p.m... proposing to use the APR function of the Model G250 airplane during go-around and is requesting approach...
Real power regulation for the utility power grid via responsive loads
McIntyre, Timothy J [Knoxville, TN; Kirby, Brendan J [Knoxville, TN; Kisner, Roger A
2009-05-19
A system for dynamically managing an electrical power system that determines measures of performance and control criteria for the electric power system, collects at least one automatic generation control (AGC) input parameter to at least one AGC module and at least one automatic load control (ALC) input parameter to at least one ALC module, calculates AGC control signals and loads as resources (LAR) control signals in response to said measures of performance and control criteria, propagates AGC control signals to power generating units in response to control logic in AGC modules, and propagates LAR control signals to at least one LAR in response to control logic in ALC modules.
Dynamic power flow controllers
Divan, Deepakraj M.; Prasai, Anish
2017-03-07
Dynamic power flow controllers are provided. A dynamic power flow controller may comprise a transformer and a power converter. The power converter is subject to low voltage stresses and not floated at line voltage. In addition, the power converter is rated at a fraction of the total power controlled. A dynamic power flow controller controls both the real and the reactive power flow between two AC sources having the same frequency. A dynamic power flow controller inserts a voltage with controllable magnitude and phase between two AC sources; thereby effecting control of active and reactive power flows between two AC sources.
Computer-assisted bladder cancer grading: α-shapes for color space decomposition
NASA Astrophysics Data System (ADS)
Niazi, M. K. K.; Parwani, Anil V.; Gurcan, Metin N.
2016-03-01
According to American Cancer Society, around 74,000 new cases of bladder cancer are expected during 2015 in the US. To facilitate the bladder cancer diagnosis, we present an automatic method to differentiate carcinoma in situ (CIS) from normal/reactive cases that will work on hematoxylin and eosin (H and E) stained images of bladder. The method automatically determines the color deconvolution matrix by utilizing the α-shapes of the color distribution in the RGB color space. Then, variations in the boundary of transitional epithelium are quantified, and sizes of nuclei in the transitional epithelium are measured. We also approximate the "nuclear to cytoplasmic ratio" by computing the ratio of the average shortest distance between transitional epithelium and nuclei to average nuclei size. Nuclei homogeneity is measured by computing the kurtosis of the nuclei size histogram. The results show that 30 out of 34 (88.2%) images were correctly classified by the proposed method, indicating that these novel features are viable markers to differentiate CIS from normal/reactive bladder.
78 FR 63176 - Notice Announcing Workshop; Zero Rate Reactive Power Rate Schedules
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-23
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. AD14-1-000] Notice Announcing Workshop; Zero Rate Reactive Power Rate Schedules Concurrent with this notice, the Commission is issuing an order in Chehalis Power Generating, L.P., Docket No. ER05-1056-007 clarifying its policy...
Reactive Power Compensation Using an Energy Management System
2014-09-01
bulk power grid or independent of the grid in islanded mode using various DG sources ( photovoltaic panels, fuel cells, gas generators, batteries...developed in order to forecast the system’s response to both capacitive and inductive power demands on the grid. The process was then confirmed in a...NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS Approved for public release; distribution is unlimited REACTIVE POWER
Reactive power planning under high penetration of wind energy using Benders decomposition
Xu, Yan; Wei, Yanli; Fang, Xin; ...
2015-11-05
This study addresses the optimal allocation of reactive power volt-ampere reactive (VAR) sources under the paradigm of high penetration of wind energy. Reactive power planning (RPP) in this particular condition involves a high level of uncertainty because of wind power characteristic. To properly model wind generation uncertainty, a multi-scenario framework optimal power flow that considers the voltage stability constraint under the worst wind scenario and transmission N 1 contingency is developed. The objective of RPP in this study is to minimise the total cost including the VAR investment cost and the expected generation cost. Therefore RPP under this condition ismore » modelled as a two-stage stochastic programming problem to optimise the VAR location and size in one stage, then to minimise the fuel cost in the other stage, and eventually, to find the global optimal RPP results iteratively. Benders decomposition is used to solve this model with an upper level problem (master problem) for VAR allocation optimisation and a lower problem (sub-problem) for generation cost minimisation. Impact of the potential reactive power support from doubly-fed induction generator (DFIG) is also analysed. Lastly, case studies on the IEEE 14-bus and 118-bus systems are provided to verify the proposed method.« less
Control of a 30 cm diameter mercury bombardment thruster
NASA Technical Reports Server (NTRS)
Terdan, F. F.; Bechtel, R. T.
1973-01-01
Increased thruster performance has made closed-loop automatic control more difficult than previously. Specifically, high perveance optics tend to make reliable recycling more difficult. Control logic functions were established for three automatic modes of operation of a 30-cm thruster using a power conditioner console with flight-like characteristics. The three modes provide (1) automatic startup to reach thermal stability, (2) steady-state closed-loop control, and (3) the reliable recycling of the high voltages following an arc breakdown to reestablish normal operation. Power supply impedance characteristics necessary for stable operation and the effect of the magnetic baffle on the reliable recycling was studied.
Path Searching Based Fault Automated Recovery Scheme for Distribution Grid with DG
NASA Astrophysics Data System (ADS)
Xia, Lin; Qun, Wang; Hui, Xue; Simeng, Zhu
2016-12-01
Applying the method of path searching based on distribution network topology in setting software has a good effect, and the path searching method containing DG power source is also applicable to the automatic generation and division of planned islands after the fault. This paper applies path searching algorithm in the automatic division of planned islands after faults: starting from the switch of fault isolation, ending in each power source, and according to the line load that the searching path traverses and the load integrated by important optimized searching path, forming optimized division scheme of planned islands that uses each DG as power source and is balanced to local important load. Finally, COBASE software and distribution network automation software applied are used to illustrate the effectiveness of the realization of such automatic restoration program.
An ultra low-power CMOS automatic action potential detector.
Gosselin, Benoit; Sawan, Mohamad
2009-08-01
We present a low-power complementary metal-oxide semiconductor (CMOS) analog integrated biopotential detector intended for neural recording in wireless multichannel implants. The proposed detector can achieve accurate automatic discrimination of action potential (APs) from the background activity by means of an energy-based preprocessor and a linear delay element. This strategy improves detected waveforms integrity and prompts for better performance in neural prostheses. The delay element is implemented with a low-power continuous-time filter using a ninth-order equiripple allpass transfer function. All circuit building blocks use subthreshold OTAs employing dedicated circuit techniques for achieving ultra low-power and high dynamic range. The proposed circuit function in the submicrowatt range as the implemented CMOS 0.18- microm chip dissipates 780 nW, and it features a size of 0.07 mm(2). So it is suitable for massive integration in a multichannel device with modest overhead. The fabricated detector succeeds to automatically detect APs from underlying background activity. Testbench validation results obtained with synthetic neural waveforms are presented.
Automated Power-Distribution System
NASA Technical Reports Server (NTRS)
Ashworth, Barry; Riedesel, Joel; Myers, Chris; Miller, William; Jones, Ellen F.; Freeman, Kenneth; Walsh, Richard; Walls, Bryan K.; Weeks, David J.; Bechtel, Robert T.
1992-01-01
Autonomous power-distribution system includes power-control equipment and automation equipment. System automatically schedules connection of power to loads and reconfigures itself when it detects fault. Potential terrestrial applications include optimization of consumption of power in homes, power supplies for autonomous land vehicles and vessels, and power supplies for automated industrial processes.
NASA Astrophysics Data System (ADS)
Chintalapudi, V. S.; Sirigiri, Sivanagaraju
2017-04-01
In power system restructuring, pricing the electrical power plays a vital role in cost allocation between suppliers and consumers. In optimal power dispatch problem, not only the cost of active power generation but also the costs of reactive power generated by the generators should be considered to increase the effectiveness of the problem. As the characteristics of reactive power cost curve are similar to that of active power cost curve, a nonconvex reactive power cost function is formulated. In this paper, a more realistic multi-fuel total cost objective is formulated by considering active and reactive power costs of generators. The formulated cost function is optimized by satisfying equality, in-equality and practical constraints using the proposed uniform distributed two-stage particle swarm optimization. The proposed algorithm is a combination of uniform distribution of control variables (to start the iterative process with good initial value) and two-stage initialization processes (to obtain best final value in less number of iterations) can enhance the effectiveness of convergence characteristics. Obtained results for the considered standard test functions and electrical systems indicate the effectiveness of the proposed algorithm and can obtain efficient solution when compared to existing methods. Hence, the proposed method is a promising method and can be easily applied to optimize the power system objectives.
14 CFR Appendix I to Part 25 - Installation of an Automatic Takeoff Thrust Control System (ATTCS)
Code of Federal Regulations, 2011 CFR
2011-01-01
... Appendix I to Part 25—Installation of an Automatic Takeoff Thrust Control System (ATTCS) I25.1General. (a... crew to increase thrust or power. I25.2Definitions. (a) Automatic Takeoff Thrust Control System (ATTCS... Control System (ATTCS) I Appendix I to Part 25 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION...
Application of point kinetics equations to the design of a reactivity meter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Binney, S.E.; Bakir, A.J.M.
1988-01-01
The time-dependent reactivity of a nuclear reactor is obviously one of the most important reactor parameters that describes the state of the reactor. Although several different types of techniques exist to measure reactivity, only the kinetic method is described here. The paper illustrates the measured reactor power and calculated reactivity for a 70 cents step change in reactivity. These data were taken at 1-s time intervals. It is seen that the reactivity, initially at zero, rises rapidly to a predetermined value (determined by the reactivity change induced in the system) and then returns to zero as the reactor is reestablishedmore » in a critical situation by insertion of another control rod. It is concluded that the method of Tuttle has been adapted to produce a reliable, on-line calculation of reactivity from a time-dependent reactor power signal.« less
Shariff, Azim F; Tracy, Jessica L; Markusoff, Jeffrey L
2012-09-01
How do we decide who merits social status? According to functionalist theories of emotion, the nonverbal expressions of pride and shame play a key role, functioning as automatically perceived status signals. In this view, observers automatically make status inferences about expressers on the basis of these expressions, even when contradictory contextual information about the expressers' status is available. In four studies, the authors tested whether implicit and explicit status perceptions are influenced by pride and shame expressions even when these expressions' status-related messages are contradicted by contextual information. Results indicate that emotion expressions powerfully influence implicit and explicit status inferences, at times neutralizing or even overriding situational knowledge. These findings demonstrate the irrepressible communicative power of emotion displays and indicate that status judgments can be informed as much (and often more) by automatic responses to nonverbal expressions of emotion as by rational, contextually bound knowledge.
Reactive Power Compensating System.
Williams, Timothy J.; El-Sharkawi, Mohamed A.; Venkata, Subrahmanyam S.
1985-01-04
The circuit was designed for the specific application of wind-driven induction generators. It has great potential for application in any situation where a varying reactive power load is present, such as with induction motors or generators, or for transmission network compensation.
78 FR 77670 - Zero Rate Reactive Power Rate Schedules; Notice Allowing Post-Workshop Comments
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-24
... staff-led workshop explored the mechanics of filing reactive power rate schedules for which there is no compensation.\\1\\ Interested persons are invited to file written comments focused on the mechanics of filing...
Power Management for Space Advanced Life Support
NASA Technical Reports Server (NTRS)
Jones, Harry
2001-01-01
Space power systems include the power source, storage, and management subsystems. In current crewed spacecraft, solar cells are the power source, batteries provide storage, and the crew performs any required load scheduling. For future crewed planetary surface systems using Advanced Life Support, we assume that plants will be grown to produce much of the crew's food and that nuclear power will be employed. Battery storage is much more costly than nuclear power capacity and so is not likely to be used. We investigate the scheduling of power demands by the crew or automatic control, to reduce the peak power load and the required generating capacity. The peak to average power ratio is a good measure of power use efficiency. We can easily schedule power demands to reduce the peak power from its maximum, but simple scheduling approaches may not find the lowest possible peak to average power ratio. An initial power scheduling example was simple enough for a human to solve, but a more complex example with many intermittent load demands required automatic scheduling. Excess power is a free resource and can be used even for minor benefits.
NASA Astrophysics Data System (ADS)
Ivanov, Yu. A.
2007-12-01
An analytical review is given of Russian and foreign measurement instruments employed in a system for automatically monitoring the water chemistry of the reactor coolant circuit and used in the development of projects of nuclear power stations equipped with VVER-1000 reactors and the nuclear station project AES 2006. The results of experience gained from the use of such measurement instruments at nuclear power stations operating in Russia and abroad are presented.
NASA Astrophysics Data System (ADS)
Krokhin, G.; Pestunov, A.; Arakelyan, E.; Mukhin, V.
2017-11-01
During the last decades, there can be noticed an increase of interest concerning various aspects of intellectual diagnostics and management in thermal power engineering according the hybrid principle. It is conditioned by the fact that conservative static methods does not allow to reflect the actual power installation state adequately. In order to improve the diagnostics quality, we use various fuzzy systems apparatus. In this paper, we introduce the intellectual system, called SKAIS, which is intended for quick and precise diagnostics of thermal power equipment. This system was developed as the result of the research carried out by specialists from National Research University “Moscow Power Engineering Institute” and Novosibirsk State University of Economics and Management. It drastically increases the level of intelligence of the automatic power plant control system.
An automated method to find transition states using chemical dynamics simulations.
Martínez-Núñez, Emilio
2015-02-05
A procedure to automatically find the transition states (TSs) of a molecular system (MS) is proposed. It has two components: high-energy chemical dynamics simulations (CDS), and an algorithm that analyzes the geometries along the trajectories to find reactive pathways. Two levels of electronic structure calculations are involved: a low level (LL) is used to integrate the trajectories and also to optimize the TSs, and a higher level (HL) is used to reoptimize the structures. The method has been tested in three MSs: formaldehyde, formic acid (FA), and vinyl cyanide (VC), using MOPAC2012 and Gaussian09 to run the LL and HL calculations, respectively. Both the efficacy and efficiency of the method are very good, with around 15 TS structures optimized every 10 trajectories, which gives a total of 7, 12, and 83 TSs for formaldehyde, FA, and VC, respectively. The use of CDS makes it a powerful tool to unveil possible nonstatistical behavior of the system under study. © 2014 Wiley Periodicals, Inc.
Design, Control, and Modeling of a New Voltage Source Converter for HVDC System
NASA Astrophysics Data System (ADS)
Mohan, Madhan; Singh, Bhim; Ketan Panigrahi, Bijaya
2013-05-01
Abstract: A New Voltage Source Converter (VSC) based on neutral clamped three-level circuit is proposed for High Voltage DC (HVDC) system. The proposed VSC is designed in a multipulse configuration. The converter is operated by Fundamental Frequency Switching (FFS). A new control method is developed for achieving all the necessary control aspects of HVDC system such as independent real and reactive power control, bidirectional real and reactive power control. The basic of the control method is varying the pulse width and by keeping the dc link voltage constant. The steady state and dynamic performances of HVDC system interconnecting two different frequencies network are demonstrated for active and reactive power control. Total number of transformers used in this system are reduced to half in comparison with the two-level VSCs for both active and reactive power control. The performance of the HVDC system is improved in terms of reduced harmonics level even at fundamental frequency switching. The harmonic performance of the designed converter is also studied for different value of the dead angle (β), and the optimized range of the dead angle is achieved for varying reactive power requirement. Simulation results are presented for the designed three level multipulse voltage source converters with the proposed control algorithm.
NASA Astrophysics Data System (ADS)
Wu, Q. H.; Ma, J. T.
1993-09-01
A primary investigation into application of genetic algorithms in optimal reactive power dispatch and voltage control is presented. The application was achieved, based on (the United Kingdom) National Grid 48 bus network model, using a novel genetic search approach. Simulation results, compared with that obtained using nonlinear programming methods, are included to show the potential of applications of the genetic search methodology in power system economical and secure operations.
The Impact of Transformer Winding Connections of A Grid-Connected PV on Voltage Quality Improvement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muljadi, Eduard; Tumbelaka, Hanny H.; Gao, Wenzhong
In this paper, the high-power PV plant is connected to the weak grid by means of a three-phase power transformer. The selection of transformer winding connection is critical especially when the PV inverter has a reactive power controller. In general, transformer winding connection can be arranged in star-star (with neutral earthed) or star-delta. The reactive power controller supports voltage regulation of the power system particularly under transient faults. Its control strategy is based on utilizing the grid currents to make a three-phase reactive unbalanced current with a small gain. The gain is determined by the system impedance. Simulation results exhibitmore » that the control strategy works very well particularly under disturbance conditions when the transformer winding connection is star-star with both neutrals grounded. The power quality in terms of the voltage quality is improved.« less
Status and Power Do Not Modulate Automatic Imitation of Intransitive Hand Movements
Farmer, Harry; Carr, Evan W.; Svartdal, Marita; Winkielman, Piotr; Hamilton, Antonia F. de C.
2016-01-01
The tendency to mimic the behaviour of others is affected by a variety of social factors, and it has been argued that such “mirroring” is often unconsciously deployed as a means of increasing affiliation during interpersonal interactions. However, the relationship between automatic motor imitation and status/power is currently unclear. This paper reports five experiments that investigated whether social status (Experiments 1, 2, and 3) or power (Experiments 4 and 5) had a moderating effect on automatic imitation (AI) in finger-movement tasks, using a series of different manipulations. Experiments 1 and 2 manipulated the social status of the observed person using an associative learning task. Experiment 3 manipulated social status via perceived competence at a simple computer game. Experiment 4 manipulated participants’ power (relative to the actors) in a card-choosing task. Finally, Experiment 5 primed participants using a writing task, to induce the sense of being powerful or powerless. No significant interactions were found between congruency and social status/power in any of the studies. Additionally, Bayesian hypothesis testing indicated that the null hypothesis should be favoured over the experimental hypothesis in all five studies. These findings are discussed in terms of their implications for AI tasks, social effects on mimicry, and the hypothesis of mimicry as a strategic mechanism to promote affiliation. PMID:27096167
Optimal reactive planning with security constraints
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, W.R.; Cheng, D.T.Y.; Dixon, A.M.
1995-12-31
The National Grid Company (NGC) of England and Wales has developed a computer program, SCORPION, to help system planners optimize the location and size of new reactive compensation plant on the transmission system. The reactive power requirements of the NGC system have risen as a result of increased power flows and the shorter timescale on which power stations are commissioned and withdrawn from service. In view of the high costs involved, it is important that reactive compensation be installed as economically as possible, without compromising security. Traditional methods based on iterative use of a load flow program are labor intensivemore » and subjective. SCORPION determines a near-optimal pattern of new reactive sources which are required to satisfy voltage constraints for normal and contingent states of operation of the transmission system. The algorithm processes the system states sequentially, instead of optimizing all of them simultaneously. This allows a large number of system states to be considered with an acceptable run time and computer memory requirement. Installed reactive sources are treated as continuous, rather than discrete, variables. However, the program has a restart facility which enables the user to add realistically sized reactive sources explicitly and thereby work towards a realizable solution to the planning problem.« less
29 CFR 1918.64 - Powered conveyors.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the brakes cannot be released until power is applied and the brakes are automatically engaged if the... provided for use in an emergency. Whenever the operation of any power conveyor requires personnel to work... the trimmer. (e) Grain trimmer power cable. Power cables between the deck control box and the grain...
NASA Astrophysics Data System (ADS)
Yu, You; Han, Yanchao; Xu, Miao; Zhang, Lingling; Dong, Shaojun
2016-04-01
Inverted illumination compensation is important in energy-saving projects, artificial photosynthesis and some forms of agriculture, such as hydroponics. However, only a few illumination adjustments based on self-powered biodetectors that quantitatively detect the intensity of visible light have been reported. We constructed an automatic illumination compensation device based on a photoelectrochemical biofuel cell (PBFC) driven by visible light. The PBFC consisted of a glucose dehydrogenase modified bioanode and a p-type semiconductor cuprous oxide photocathode. The PBFC had a high power output of 161.4 μW cm-2 and an open circuit potential that responded rapidly to visible light. It adjusted the amount of illumination inversely irrespective of how the external illumination was changed. This rational design of utilizing PBFCs provides new insights into automatic light adjustable devices and may be of benefit to intelligent applications.Inverted illumination compensation is important in energy-saving projects, artificial photosynthesis and some forms of agriculture, such as hydroponics. However, only a few illumination adjustments based on self-powered biodetectors that quantitatively detect the intensity of visible light have been reported. We constructed an automatic illumination compensation device based on a photoelectrochemical biofuel cell (PBFC) driven by visible light. The PBFC consisted of a glucose dehydrogenase modified bioanode and a p-type semiconductor cuprous oxide photocathode. The PBFC had a high power output of 161.4 μW cm-2 and an open circuit potential that responded rapidly to visible light. It adjusted the amount of illumination inversely irrespective of how the external illumination was changed. This rational design of utilizing PBFCs provides new insights into automatic light adjustable devices and may be of benefit to intelligent applications. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr00759g
Atypical Mismatch Negativity to Distressful Voices Associated with Conduct Disorder Symptoms
ERIC Educational Resources Information Center
Hung, An-Yi; Ahveninen, Jyrki; Cheng, Yawei
2013-01-01
Background: Although a general consensus holds that emotional reactivity in youth with conduct disorder (CD) symptoms arises as one of the main causes of successive aggression, it remains to be determined whether automatic emotional processing is altered in this population. Methods: We measured auditory event-related potentials (ERP) in 20 young…
Leap Frog and Time Step Sub-Cycle Scheme for Coupled Neutronics and Thermal-Hydraulic Codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, S.
2002-07-01
As the result of the advancing TCP/IP based inter-process communication technology, more and more legacy thermal-hydraulic codes have been coupled with neutronics codes to provide best-estimate capabilities for reactivity related reactor transient analysis. Most of the coupling schemes are based on closely coupled serial or parallel approaches. Therefore, the execution of the coupled codes usually requires significant CPU time, when a complicated system is analyzed. Leap Frog scheme has been used to reduce the run time. The extent of the decoupling is usually determined based on a trial and error process for a specific analysis. It is the intent ofmore » this paper to develop a set of general criteria, which can be used to invoke the automatic Leap Frog algorithm. The algorithm will not only provide the run time reduction but also preserve the accuracy. The criteria will also serve as the base of an automatic time step sub-cycle scheme when a sudden reactivity change is introduced and the thermal-hydraulic code is marching with a relatively large time step. (authors)« less
Dudschig, Carolin; de la Vega, Irmgard; Kaup, Barbara
2014-05-01
Converging evidence suggests that understanding our first-language (L1) results in reactivation of experiential sensorimotor traces in the brain. Surprisingly, little is known regarding the involvement of these processes during second-language (L2) processing. Participants saw L1 or L2 words referring to entities with a typical location (e.g., star, mole) (Experiment 1 & 2) or to an emotion (e.g., happy, sad) (Experiment 3). Participants responded to the words' ink color with an upward or downward arm movement. Despite word meaning being fully task-irrelevant, L2 automatically activated motor responses similar to L1 even when L2 was acquired rather late in life (age >11). Specifically, words such as star facilitated upward, and words such as root facilitated downward responses. Additionally, words referring to positive emotions facilitated upward, and words referring to negative emotions facilitated downward responses. In summary our study suggests that reactivation of experiential traces is not limited to L1 processing. Copyright © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, Tao; Li, Cheng; Huang, Can
Here, in order to solve the reactive power optimization with joint transmission and distribution networks, a hierarchical modeling method is proposed in this paper. It allows the reactive power optimization of transmission and distribution networks to be performed separately, leading to a master–slave structure and improves traditional centralized modeling methods by alleviating the big data problem in a control center. Specifically, the transmission-distribution-network coordination issue of the hierarchical modeling method is investigated. First, a curve-fitting approach is developed to provide a cost function of the slave model for the master model, which reflects the impacts of each slave model. Second,more » the transmission and distribution networks are decoupled at feeder buses, and all the distribution networks are coordinated by the master reactive power optimization model to achieve the global optimality. Finally, numerical results on two test systems verify the effectiveness of the proposed hierarchical modeling and curve-fitting methods.« less
Ding, Tao; Li, Cheng; Huang, Can; ...
2017-01-09
Here, in order to solve the reactive power optimization with joint transmission and distribution networks, a hierarchical modeling method is proposed in this paper. It allows the reactive power optimization of transmission and distribution networks to be performed separately, leading to a master–slave structure and improves traditional centralized modeling methods by alleviating the big data problem in a control center. Specifically, the transmission-distribution-network coordination issue of the hierarchical modeling method is investigated. First, a curve-fitting approach is developed to provide a cost function of the slave model for the master model, which reflects the impacts of each slave model. Second,more » the transmission and distribution networks are decoupled at feeder buses, and all the distribution networks are coordinated by the master reactive power optimization model to achieve the global optimality. Finally, numerical results on two test systems verify the effectiveness of the proposed hierarchical modeling and curve-fitting methods.« less
NASA Astrophysics Data System (ADS)
Biskup, B.; Maszl, C.; Breilmann, W.; Held, J.; Böke, M.; Benedikt, J.; von Keudell, A.
2018-03-01
High power impulse magnetron sputtering (HiPIMS) discharges are an excellent tool for deposition of thin films with superior properties. By adjusting the plasma parameters, an energetic metal and reactive species growth flux can be controlled. This control requires, however, a quantitative knowledge of the ion-to-neutral ratio in the growth flux and of the ion energy distribution function to optimize the deposited energy per incorporated atom in the film. This quantification is performed by combining two diagnostics, a quartz crystal microbalance (QCM) combined with an ion-repelling grid system (IReGS) to discriminate ions versus neutrals and a HIDEN EQP plasma monitor to measure the ion energy distribution function (IEDF). This approach yields the ionized metal flux fraction (IMFF) as the ionization degree in the growth flux. This is correlated to the plasma performance recorded by time resolved ICCD camera measurements, which allow to identify the formation of pronounced ionization zones, so called spokes, in the HiPIMS plasma. Thereby an automatic technique was developed to identify the spoke mode number. The data indicates two distinct regimes with respect to spoke formation that occur with increasing peak power, a stochastic regime with no spokes at low peak powers followed by a regime with distinct spokes at varying mode numbers at higher peak powers. The IMFF increases with increasing peak power reaching values of almost 80% at very high peak powers. The transition in between the two regimes coincides with a pronounced change in the IMFF. This change indicates that the formation of spokes apparently counteracts the return effect in HiPIMS. Based on the IMFF and the mean energy of the ions, the energy per deposited atom together with the overall energy flux onto the substrate is calculated. This allows us to determine an optimum for the peak power density around 0.5 kW cm-2 for chromium HiPIMS.
Self-powered automatic secondary air controllers for woodstoves and small furnaces
Siemer, Darryl D.
1991-01-01
A controller for automatically regulating the supply of secondary combustion air to woodstoves and small furnaces. The controller includes a movable air valve for controlling the amount of secondary air admitted into the chamber. A self powered means monitors the concentration of combustible gases and vapors and actuates the movable air valve to increase the supply of secondary air in response to increasing concentrations of the combustible gases and vapors. The self-powered means can be two fluid filled sensor bulbs, one of which has a coating of a combustion catalyst. Alternatively, the self powered means can be two metallic stripes laminated together, one of which is coated with a combustion catalyst, and when heated, causes the air valve to actuate.
Ibraheem; Hasan, Naimul; Hussein, Arkan Ahmed
2014-01-01
This Paper presents the design of decentralized automatic generation controller for an interconnected power system using PID, Genetic Algorithm (GA) and Particle Swarm Optimization (PSO). The designed controllers are tested on identical two-area interconnected power systems consisting of thermal power plants. The area interconnections between two areas are considered as (i) AC tie-line only (ii) Asynchronous tie-line. The dynamic response analysis is carried out for 1% load perturbation. The performance of the intelligent controllers based on GA and PSO has been compared with the conventional PID controller. The investigations of the system dynamic responses reveal that PSO has the better dynamic response result as compared with PID and GA controller for both type of area interconnection.
NASA Astrophysics Data System (ADS)
Zhao, Yan; Yang, Zijiang; Gao, Song; Liu, Jinbiao
2018-02-01
Automatic generation control(AGC) is a key technology to maintain real time power generation and load balance, and to ensure the quality of power supply. Power grids require each power generation unit to have a satisfactory AGC performance, being specified in two detailed rules. The two rules provide a set of indices to measure the AGC performance of power generation unit. However, the commonly-used method to calculate these indices is based on particular data samples from AGC responses and will lead to incorrect results in practice. This paper proposes a new method to estimate the AGC performance indices via system identification techniques. In addition, a nonlinear regression model between performance indices and load command is built in order to predict the AGC performance indices. The effectiveness of the proposed method is validated through industrial case studies.
38 CFR 17.157 - Definition-adaptive equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... includes, but is not limited to, a basic automatic transmission, power steering, power brakes, power window lifts, power seats, air-conditioning equipment when necessary for the health and safety of the veteran... MEDICAL Automotive Equipment and Driver Training § 17.157 Definition-adaptive equipment. The term...
47 CFR 74.534 - Power limitations.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., transmitter output power shall not exceed 10 watts. (b) In no event shall the average equivalent isotropically..., order a change in the equivalent isotropically radiated power of this station. Frequency band (MHz..., subject to periodic renewal. (c) The EIRP of transmitters that use Automatic Transmitter Power Control...
47 CFR 74.534 - Power limitations.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., transmitter output power shall not exceed 10 watts. (b) In no event shall the average equivalent isotropically..., order a change in the equivalent isotropically radiated power of this station. Frequency band (MHz..., subject to periodic renewal. (c) The EIRP of transmitters that use Automatic Transmitter Power Control...
NASA Astrophysics Data System (ADS)
Larin, A. B.; Kolegov, A. V.
2012-10-01
Results of industrial tests of the new method used for the automatic chemical control of the quality of boiler water of the drum-type power boiler ( P d = 13.8 MPa) are described. The possibility of using an H-cationite column for measuring the electric conductivity of an H-cationized sample of boiler water over a long period of time is shown.
A flight-test evaluation of a go-around control system for a twin engine powered-lift STOL airplane
NASA Technical Reports Server (NTRS)
Watson, D. M.; Hardy, G. H.
1983-01-01
An automatic go-around control system was evaluated on the Augmentor Wing Jet Short Takeoff and Landing (STOL) Research Airplane (AWJSRA) as part of a study of an automatic landing system for a powered-lift STOL airplane. The results of the evaluation indicate that the go-around control system can successfully transition the airplane to a climb configuration from any initiation point during the glide-slope track or the flare maneuver prior to touchdown.
Equations for Automotive-Transmission Performance
NASA Technical Reports Server (NTRS)
Chazanoff, S.; Aston, M. B.; Chapman, C. P.
1984-01-01
Curve-fitting procedure ensures high confidence levels. Threedimensional plot represents performance of small automatic transmission coasting in second gear. In equation for plot, PL power loss, S speed and T torque. Equations applicable to manual and automatic transmissions over wide range of speed, torque, and efficiency.
High-powered automatic latching device
NASA Technical Reports Server (NTRS)
Cobin, J. C.; Rhodes, L. L.
1970-01-01
Latches automatically lock together two remotely controlled bodies when their triggers are engaged by the docking ring of the lesser body. Latches are disengaged by manual actuation of the handle of each latch through two complete cycles. Emergency locking by manual actuation is also provided.
Automatic marker for photographic film
NASA Technical Reports Server (NTRS)
Gabbard, N. M.; Surrency, W. M.
1974-01-01
Commercially-produced wire-marking machine is modified to title or mark film rolls automatically. Machine is used with film drive mechanism which is powered with variable-speed, 28-volt dc motor. Up to 40 frames per minute can be marked, reducing time and cost of process.
Automatic Generation Control Study in Two Area Reheat Thermal Power System
NASA Astrophysics Data System (ADS)
Pritam, Anita; Sahu, Sibakanta; Rout, Sushil Dev; Ganthia, Sibani; Prasad Ganthia, Bibhu
2017-08-01
Due to industrial pollution our living environment destroyed. An electric grid system has may vital equipment like generator, motor, transformers and loads. There is always be an imbalance between sending end and receiving end system which cause system unstable. So this error and fault causing problem should be solved and corrected as soon as possible else it creates faults and system error and fall of efficiency of the whole power system. The main problem developed from this fault is deviation of frequency cause instability to the power system and may cause permanent damage to the system. Therefore this mechanism studied in this paper make the system stable and balance by regulating frequency at both sending and receiving end power system using automatic generation control using various controllers taking a two area reheat thermal power system into account.
Dorris, Derek C
2009-11-01
Ego-depletion (depletion of self-regulatory strength) can impair conscious efforts at self-regulation. Research into nonconscious self-regulation has demonstrated that preconscious automaticity and implementation intentions can automatically carry out regulatory tasks during times of ego-depletion. However, preconscious automaticity can only emerge during well-practiced tasks while implementation intentions can only support tasks that have been explicitly planned. Thus, when it comes to supporting the conscious self-regulation of nonroutine and unplanned behaviour during times of ego-depletion these processes should be ineffective. However, it is argued here that because the conscious self-regulation of nonroutine and unplanned behaviour can incidentally prime the underlying mental representations those primed representations can be postconsciously re-activated to support that behaviour during times of ego-depletion. Postconscious self-regulation might, therefore, support a type of self-regulatory behaviour that has, thus far, not been associated with any form of support.
Garland, Eric L.; Boettiger, Charlotte A.; Howard, Matthew O.
2011-01-01
This paper proposes a novel hypothetical model integrating formerly discrete theories of stress appraisal, neurobiological allostasis, automatic cognitive processing, and addictive behavior to elucidate how alcohol misuse and dependence are maintained and re-activated by stress. We outline a risk chain in which psychosocial stress initiates physiological arousal, perseverative cognition, and negative affect that, in turn, triggers automatized schema to compel alcohol consumption. This implicit cognitive process then leads to attentional biases toward alcohol, subjective experiences of craving, paradoxical increases in arousal and alcohol-related cognitions due to urge suppression, and palliative coping through drinking. When palliative coping relieves distress, it results in negative reinforcement conditioning that perpetuates the cycle by further sensitizing the system to future stressful encounters. This model has implications for development and implementation of innovative behavioral interventions (such as mindfulness training) that disrupt cognitive-affective mechanisms underpinning stress-precipitated dependence on alcohol. PMID:21354711
Improving Advanced Inverter Control Convergence in Distribution Power Flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nagarajan, Adarsh; Palmintier, Bryan; Ding, Fei
Simulation of modern distribution system powerflow increasingly requires capturing the impact of advanced PV inverter voltage regulation on powerflow. With Volt/var control, the inverter adjusts its reactive power flow as a function of the point of common coupling (PCC) voltage. Similarly, Volt/watt control curtails active power production as a function of PCC voltage. However, with larger systems and higher penetrations of PV, this active/reactive power flow itself can cause significant changes to the PCC voltage potentially introducing oscillations that slow the convergence of system simulations. Improper treatment of these advanced inverter functions could potentially lead to incorrect results. This papermore » explores a simple approach to speed such convergence by blending in the previous iteration's reactive power estimate to dampen these oscillations. Results with a single large (5MW) PV system and with multiple 500kW advanced inverters show dramatic improvements using this approach.« less
NASA Astrophysics Data System (ADS)
Kortström, Jari; Tiira, Timo; Kaisko, Outi
2016-03-01
The Institute of Seismology of University of Helsinki is building a new local seismic network, called OBF network, around planned nuclear power plant in Northern Ostrobothnia, Finland. The network will consist of nine new stations and one existing station. The network should be dense enough to provide azimuthal coverage better than 180° and automatic detection capability down to ML -0.1 within a radius of 25 km from the site.The network construction work began in 2012 and the first four stations started operation at the end of May 2013. We applied an automatic seismic signal detection and event location system to a network of 13 stations consisting of the four new stations and the nearest stations of Finnish and Swedish national seismic networks. Between the end of May and December 2013 the network detected 214 events inside the predefined area of 50 km radius surrounding the planned nuclear power plant site. Of those detections, 120 were identified as spurious events. A total of 74 events were associated with known quarries and mining areas. The average location error, calculated as a difference between the announced location from environment authorities and companies and the automatic location, was 2.9 km. During the same time period eight earthquakes between magnitude range 0.1-1.0 occurred within the area. Of these seven could be automatically detected. The results from the phase 1 stations of the OBF network indicates that the planned network can achieve its goals.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morellas, Vassilios; Johnson, Andrew; Johnston, Chris
2006-07-01
Thermal imaging is rightfully a real-world technology proven to bring confidence to daytime, night-time and all weather security surveillance. Automatic image processing intrusion detection algorithms are also a real world technology proven to bring confidence to system surveillance security solutions. Together, day, night and all weather video imagery sensors and automated intrusion detection software systems create the real power to protect early against crime, providing real-time global homeland protection, rather than simply being able to monitor and record activities for post event analysis. These solutions, whether providing automatic security system surveillance at airports (to automatically detect unauthorized aircraft takeoff andmore » landing activities) or at high risk private, public or government facilities (to automatically detect unauthorized people or vehicle intrusion activities) are on the move to provide end users the power to protect people, capital equipment and intellectual property against acts of vandalism and terrorism. As with any technology, infrared sensors and automatic image intrusion detection systems for global homeland security protection have clear technological strengths and limitations compared to other more common day and night vision technologies or more traditional manual man-in-the-loop intrusion detection security systems. This paper addresses these strength and limitation capabilities. False Alarm (FAR) and False Positive Rate (FPR) is an example of some of the key customer system acceptability metrics and Noise Equivalent Temperature Difference (NETD) and Minimum Resolvable Temperature are examples of some of the sensor level performance acceptability metrics. (authors)« less
Vongas, John G; Al Hajj, Raghid
2017-06-01
A contribution to a special issue on Hormones and Human Competition. We investigated the effects of competition on men's testosterone levels and assessed whether androgen reactivity was associated with subsequent emotion recognition and reactive and proactive aggression. We also explored whether personalized power (p Power) moderated these relationships. In Study 1, 84 males competed on a number tracing task and interpreted emotions from facial expressions. In Study 2, 72 males competed on the same task and were assessed on proactive and reactive aggression. In both studies, contrary to the biosocial model of status (Mazur, 1985), winners' testosterone levels decreased significantly while losers' levels increased, albeit not significantly. Personalized power moderated the effect of competition outcome on testosterone change in both studies. Using the aggregate sample, we found that the effect of decreased testosterone levels among winners (compared to losers) was significant for individuals low in p Power but not for those with medium or high p Power. Testosterone change was positively related to emotion recognition, but unrelated to either aggression subtype. The testosterone-mediated relationship between winning and losing and emotion recognition was moderated by p Power. In addition, p Power moderated the direct (i.e., non-testosterone mediated) path between competition outcome and emotion recognition and both types of aggression: high p-Power winners were more accurate at deciphering others' emotions than high p-Power losers. Finally, among high p-Power men, winners aggressed more proactively than losers, whereas losers aggressed more reactively than winners. Collectively, these studies highlight the importance of implicit power motivation in modulating hormonal, cognitive, and behavioral outcomes arising from human competition. Copyright © 2017 Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-1 General. This subpart contains requirements applicable to emergency power installations having...
Code of Federal Regulations, 2012 CFR
2012-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-1 General. This subpart contains requirements applicable to emergency power installations having...
Code of Federal Regulations, 2011 CFR
2011-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-1 General. This subpart contains requirements applicable to emergency power installations having...
Code of Federal Regulations, 2010 CFR
2010-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-1 General. This subpart contains requirements applicable to emergency power installations having...
Code of Federal Regulations, 2013 CFR
2013-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-1 General. This subpart contains requirements applicable to emergency power installations having...
49 CFR 236.516 - Power supply.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Power supply. 236.516 Section 236.516..., Train Control and Cab Signal Systems Standards § 236.516 Power supply. Automatic cab signal, train stop, or train control device hereafter installed shall operate from a separate or isolated power supply...
49 CFR 236.516 - Power supply.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Power supply. 236.516 Section 236.516..., Train Control and Cab Signal Systems Standards § 236.516 Power supply. Automatic cab signal, train stop, or train control device hereafter installed shall operate from a separate or isolated power supply...
Automatic Detection of Electric Power Troubles (ADEPT)
NASA Technical Reports Server (NTRS)
Wang, Caroline; Zeanah, Hugh; Anderson, Audie; Patrick, Clint; Brady, Mike; Ford, Donnie
1988-01-01
ADEPT is an expert system that integrates knowledge from three different suppliers to offer an advanced fault-detection system, and is designed for two modes of operation: real-time fault isolation and simulated modeling. Real time fault isolation of components is accomplished on a power system breadboard through the Fault Isolation Expert System (FIES II) interface with a rule system developed in-house. Faults are quickly detected and displayed and the rules and chain of reasoning optionally provided on a Laser printer. This system consists of a simulated Space Station power module using direct-current power supplies for Solar arrays on three power busses. For tests of the system's ability to locate faults inserted via switches, loads are configured by an INTEL microcomputer and the Symbolics artificial intelligence development system. As these loads are resistive in nature, Ohm's Law is used as the basis for rules by which faults are located. The three-bus system can correct faults automatically where there is a surplus of power available on any of the three busses. Techniques developed and used can be applied readily to other control systems requiring rapid intelligent decisions. Simulated modelling, used for theoretical studies, is implemented using a modified version of Kennedy Space Center's KATE (Knowledge-Based Automatic Test Equipment), FIES II windowing, and an ADEPT knowledge base. A load scheduler and a fault recovery system are currently under development to support both modes of operation.
PEEL-AND-STICK SENSORS POWERED BY DIRECTED RF ENERGY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lalau-Keraly, Chrisopher; Daniel, George; Lee, Joseph
PARC, a Xerox Company, is developing a low-cost system of peel-and-stick wireless sensors that will enable widespread building environment sensor deployment with the potential to deliver up to 30% energy savings. The system is embodied by a set of RF hubs that provide power to automatically located sensor nodes, and relay data wirelessly to the building management system (BMS). The sensor nodes are flexible electronic labels powered by rectified RF energy transmitted by an RF hub and can contain multiple printed and conventional sensors. The system design overcomes limitations in wireless sensors related to power delivery, lifetime, and cost bymore » eliminating batteries and photovoltaic devices. Sensor localization is performed automatically by the inclusion of a programmable multidirectional antenna array in the RF hub. Comparison of signal strengths while the RF beam is swept allows for sensor localization, reducing installation effort and enabling automatic recommissioning of sensors that have been relocated, overcoming a significant challenge in building operations. PARC has already demonstrated wireless power and temperature data transmission up to a distance of 20m with less than one minute between measurements, using power levels well within the FCC regulation limits in the 902-928 MHz ISM band. The sensor’s RF energy harvesting antenna achieves high performance with dimensions below 5cm x 9cm.« less
Peel-and-Stick Sensors Powered by Directed RF Energy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lalau-Keraly, Christopher; Daniel, George; Lee, Joseph
PARC, a Xerox Company, is developing a low-cost system of peel-and-stick wireless sensors that will enable widespread building environment sensor deployment with the potential to deliver up to 30% energy savings. The system is embodied by a set of RF hubs that provide power to automatically located sensor nodes, and relay data wirelessly to the building management system (BMS). The sensor nodes are flexible electronic labels powered by rectified RF energy transmitted by an RF hub and can contain multiple printed and conventional sensors. The system design overcomes limitations in wireless sensors related to power delivery, lifetime, and cost bymore » eliminating batteries and photovoltaic devices. Sensor localization is performed automatically by the inclusion of a programmable multidirectional antenna array in the RF hub. Comparison of signal strengths while the RF beam is swept allows for sensor localization, reducing installation effort and enabling automatic recommissioning of sensors that have been relocated, overcoming a significant challenge in building operations. PARC has already demonstrated wireless power and temperature data transmission up to a distance of 20m with less than one minute between measurements, using power levels well within the FCC regulation limits in the 902-928 MHz ISM band. The sensor’s RF energy harvesting antenna achieves high performance with dimensions below 5cm x 9cm« less
NASA Astrophysics Data System (ADS)
Li, Cheng
Wind farms, photovoltaic arrays, fuel cells, and micro-turbines are all considered to be Distributed Generation (DG). DG is defined as the generation of power which is dispersed throughout a utility's service territory and either connected to the utility's distribution system or isolated in a small grid. This thesis addresses modeling and economic issues pertaining to the optimal reactive power planning for distribution system with wind power generation (WPG) units. Wind farms are inclined to cause reverse power flows and voltage variations due to the random-like outputs of wind turbines. To deal with this kind of problem caused by wide spread usage of wind power generation, this thesis investigates voltage and reactive power controls in such a distribution system. Consequently static capacitors (SC) and transformer taps are introduced into the system and treated as controllers. For the purpose of getting optimum voltage and realizing reactive power control, the research proposes a proper coordination among the controllers like on-load tap changer (OLTC), feeder-switched capacitors. What's more, in order to simulate its uncertainty, the wind power generation is modeled by the Markov model. In that way, calculating the probabilities for all the scenarios is possible. Some outputs with consecutive and discrete values have been used for transition between successive time states and within state wind speeds. The thesis will describe the method to generate the wind speed time series from the transition probability matrix. After that, utilizing genetic algorithm, the optimal locations of SCs, the sizes of SCs and transformer taps are determined so as to minimize the cost or minimize the power loss, and more importantly improve voltage profiles. The applicability of the proposed method is verified through simulation on a 9-bus system and a 30-bus system respectively. At last, the simulation results indicate that as long as the available capacitors are able to sufficiently compensate the reactive power demand, the DG operation no longer imposes a significant effect on the voltage fluctuations in the distribution system. And the proposed approach is efficient, simple and straightforward.
Optimal Coordinated EV Charging with Reactive Power Support in Constrained Distribution Grids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paudyal, Sumit; Ceylan, Oğuzhan; Bhattarai, Bishnu P.
Electric vehicle (EV) charging/discharging can take place in any P-Q quadrants, which means EVs could support reactive power to the grid while charging the battery. In controlled charging schemes, distribution system operator (DSO) coordinates with the charging of EV fleets to ensure grid’s operating constraints are not violated. In fact, this refers to DSO setting upper bounds on power limits for EV charging. In this work, we demonstrate that if EVs inject reactive power into the grid while charging, DSO could issue higher upper bounds on the active power limits for the EVs for the same set of grid constraints.more » We demonstrate the concept in an 33-node test feeder with 1,500 EVs. Case studies show that in constrained distribution grids in coordinated charging, average costs of EV charging could be reduced if the charging takes place in the fourth P-Q quadrant compared to charging with unity power factor.« less
Garland, Eric L; Franken, Ingmar H; Sheetz, John J; Howard, Matthew O
2012-06-01
When alcohol-dependent individuals are exposed to drinking-related cues, they exhibit psychophysiological reactivity such as changes in heart rate variability (HRV) and skin temperature. Moreover, such alcohol cue-reactivity may co-occur with attentional bias (AB) toward alcohol cues. In turn, stress may promote appetitive responses by exacerbating these autonomic and attentional factors. Although cue-reactivity paradigms have been used for decades to probe such automatic appetitive processes in persons with alcohol-use disorders, less is known about the attentional correlates of alcohol cue-reactivity. In this study, alcohol-dependent adults (N = 58) recruited from a residential treatment facility completed a spatial cueing task as a measure of alcohol AB and affect-modulated cue-reactivity protocol. Multiple linear regression analyses revealed that alcohol AB was significantly positively associated with parasympathetically mediated HRV and finger temperature slope and inversely associated with sympathetically mediated HRV during stress-primed alcohol cue-exposure, independent of alcohol dependence severity, time in treatment, alcohol craving, and perceived stress. Study findings suggest that alcohol AB is linked with physiological cue-reactivity and that different attentional strategies are associated with distinct profiles of autonomic responses that may ultimately index or confer additional risk for alcohol dependence.
Silva, Alessandro Jose Nunes da; Almeida, Ildeberto Muniz de; Vilela, Rodolfo Andrade de Gouveia; Mendes, Renata Wey Berti; Hurtado, Sandra Lorena Beltran
2018-05-10
The Brazilian electricity sector has recorded high work-related mortality rates that have been associated with outsourcing, used to cut costs. In order to decrease the power outage time for consumers, the industry adopted the automatic circuit recloser as the technical solution. The device has hazardous implications for maintenance workers. The aim of this study was to analyze the origins and consequences of work accidents in power systems with automatic circuit recloser, using the Accident Analysis and Prevention (AAP) model. The AAP model was used to investigate two work accidents, aimed to explore the events' organizational origins. Case 1 - when changing a deenergized secondary line, a worker received a shock from the energized primary cable (13.8kV). The system reclosed three times, causing severe injury to the worker (amputation of a lower limb). Case 2 - a fatal work accident occurred during installation of a new crosshead on a partially insulated energized line. The tip of a metal cross arm section strap touched the energized secondary line and electrocuted the maintenance operator. The circuit breaker component of the automatic circuit recloser failed. The analyses revealed how business management logic can participate in the root causes of work accidents through failures in maintenance management, outsourced workforce management, and especially safety management in systems with reclosers. Decisions to adopt automation to guarantee power distribution should not overlook the risks to workers in overhead power lines or fail to acknowledge the importance of ensuring safe conditions.
Index-based reactive power compensation scheme for voltage regulation
NASA Astrophysics Data System (ADS)
Dike, Damian Obioma
2008-10-01
Increasing demand for electrical power arising from deregulation and the restrictions posed to the construction of new transmission lines by environment, socioeconomic, and political issues had led to higher grid loading. Consequently, voltage instability has become a major concern, and reactive power support is vital to enhance transmission grid performance. Improved reactive power support to distressed grid is possible through the application of relatively unfamiliar emerging technologies of "Flexible AC Transmission Systems (FACTS)" devices and "Distributed Energy Resources (DERS)." In addition to these infrastructure issues, a lack of situational awareness by system operators can cause major power outages as evidenced by the August 14, 2003 widespread North American blackout. This and many other recent major outages have highlighted the inadequacies of existing power system indexes. In this work, a novel "Index-based reactive compensation scheme" appropriate for both on-line and off-line computation of grid status has been developed. A new voltage stability index (Ls-index) suitable for long transmission lines was developed, simulated, and compared to the existing two-machine modeled L-index. This showed the effect of long distance power wheeling amongst regional transmission organizations. The dissertation further provided models for index modulated voltage source converters (VSC) and index-based load flow analysis of both FACTS and microgrid interconnected power systems using the Newton-Raphson's load flow model incorporated with multi-FACTS devices. The developed package has been made user-friendly through the embodiment of interactive graphical user interface and implemented on the IEEE 14, 30, and 300 bus systems. The results showed reactive compensation has system wide-effect, provided readily accessible system status indicators, ensured seamless DERs interconnection through new islanding modes and enhanced VSC utilization. These outcomes may contribute to optimal utilization of compensation devices and available transfer capability as well as reduce system outages through better regulation of power operating voltages.
Manufacturing Methods and Technology Program Automatic In-Process Microcircuit Evaluation.
1978-09-01
illumination system consists of an illuminati on controlle r , three illumination power- supplies , and three illuminator housings . The illumination... illuminati on level. - - The main power (115 V , 60 Hz) for the power-supplies is derived from the power distribu- tion panel. There are two switches In the
Design and implementation of a simple nuclear power plant simulator
NASA Astrophysics Data System (ADS)
Miller, William H.
1983-02-01
A simple PWR nuclear power plant simulator has been designed and implemented on a minicomputer system. The system is intended for students use in understanding the power operation of a nuclear power plant. A PDP-11 minicomputer calculates reactor parameters in real time, uses a graphics terminal to display the results and a keyboard and joystick for control functions. Plant parameters calculated by the model include the core reactivity (based upon control rod positions, soluble boron concentration and reactivity feedback effects), the total core power, the axial core power distribution, the temperature and pressure in the primary and secondary coolant loops, etc.
NASA Astrophysics Data System (ADS)
Wang, Jen-Cheng; Liao, Min-Sheng; Lee, Yeun-Chung; Liu, Cheng-Yue; Kuo, Kun-Chang; Chou, Cheng-Ying; Huang, Chen-Kang; Jiang, Joe-Air
2018-02-01
The performance of photovoltaic (PV) modules under outdoor operation is greatly affected by their location and environmental conditions. The temperature of a PV module gradually increases as it is exposed to solar irradiation, resulting in degradation of its electrical characteristics and power generation efficiency. This study adopts wireless sensor network (WSN) technology to develop an automatic water-cooling system for PV modules in order to improve their PV power generation efficiency. A temperature estimation method is developed to quickly and accurately estimate the PV module temperatures based on weather data provided from the WSN monitoring system. Further, an estimation method is also proposed for evaluation of the electrical characteristics and output power of the PV modules, which is performed remotely via a control platform. The automatic WSN-based water-cooling mechanism is designed to avoid the PV module temperature from reaching saturation. Equipping each PV module with the WSN-based cooling system, the ambient conditions are monitored automatically so that the temperature of the PV module is controlled by sprinkling water on the panel surface. The field-test experiment results show an increase in the energy harvested by the PV modules of approximately 17.75% when using the proposed WSN-based cooling system.
Qualification of CASMO5 / SIMULATE-3K against the SPERT-III E-core cold start-up experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grandi, G.; Moberg, L.
SIMULATE-3K is a three-dimensional kinetic code applicable to LWR Reactivity Initiated Accidents. S3K has been used to calculate several international recognized benchmarks. However, the feedback models in the benchmark exercises are different from the feedback models that SIMULATE-3K uses for LWR reactors. For this reason, it is worth comparing the SIMULATE-3K capabilities for Reactivity Initiated Accidents against kinetic experiments. The Special Power Excursion Reactor Test III was a pressurized-water, nuclear-research facility constructed to analyze the reactor kinetic behavior under initial conditions similar to those of commercial LWRs. The SPERT III E-core resembles a PWR in terms of fuel type, moderator,more » coolant flow rate, and system pressure. The initial test conditions (power, core flow, system pressure, core inlet temperature) are representative of cold start-up, hot start-up, hot standby, and hot full power. The qualification of S3K against the SPERT III E-core measurements is an ongoing work at Studsvik. In this paper, the results for the 30 cold start-up tests are presented. The results show good agreement with the experiments for the reactivity initiated accident main parameters: peak power, energy release and compensated reactivity. Predicted and measured peak powers differ at most by 13%. Measured and predicted reactivity compensations at the time of the peak power differ less than 0.01 $. Predicted and measured energy release differ at most by 13%. All differences are within the experimental uncertainty. (authors)« less
NASA Astrophysics Data System (ADS)
Chen, Zeyu; Cui, Qingjie; Chen, Chen; Xu, Dehui; Liu, Dingxin; Chen, H. L.; Kong, Michael G.
2018-02-01
In plasma cancer therapy, the inactivation of cancer cells under plasma treatment is closely related to the reactive oxygen and nitrogen species (RONS) induced by plasmas. Quantitative study on the plasma-induced RONS that related to cancer cells apoptosis is critical for advancing the research of plasma cancer therapy. In this paper, the effects of several reactive species on the inactivation of LP-1 myeloma cancer cells are comparatively studied with variable working gas composition, surrounding gas composition, and discharge power. The results show that helium plasma jet has a higher cell inactivation efficiency than argon plasma jet under the same discharge power. By comparing the concentration of aqueous phase reactive species and the cell inactivation efficiency under different working gases and discharge powers, it is demonstrated that the inactivation efficiency of LP-1 myeloma cancer cells is strongly correlated with the concentration of peroxynitrite (ONOOH/ONOO-).
Lapate, R.C.; Rokers, B.; Li, T.; Davidson, R.J.
2014-01-01
Emotions can color our attitudes toward unrelated objects in the environment. Prior evidence suggests that such emotional coloring is particularly strong when emotion-triggering information escapes conscious awareness. But, is emotional reactivity stronger following non-conscious versus conscious emotional provocation? Or does conscious processing specifically change the association between emotional reactivity and evaluations of unrelated objects? In this study, we independently indexed emotional reactivity and coloring as a function of emotional-stimulus awareness to disentangle these accounts. Specifically, we recorded skin conductance responses (SCRs) to spiders and fearful faces, along with subsequent preferences for novel neutral faces during visually aware and unaware states. Fearful faces increased SCRs comparably in both aware and unaware conditions. Yet, only when visual awareness was precluded did SCRs to fearful faces predict decreased likeability of neutral faces. These findings suggest a regulatory role for conscious awareness in breaking otherwise automatic associations between physiological reactivity and evaluative emotional responses. PMID:24317420
Lapate, Regina C; Rokers, Bas; Li, Tianyi; Davidson, Richard J
2014-02-01
Emotions can color people's attitudes toward unrelated objects in the environment. Existing evidence suggests that such emotional coloring is particularly strong when emotion-triggering information escapes conscious awareness. But is emotional reactivity stronger after nonconscious emotional provocation than after conscious emotional provocation, or does conscious processing specifically change the association between emotional reactivity and evaluations of unrelated objects? In this study, we independently indexed emotional reactivity and coloring as a function of emotional-stimulus awareness to disentangle these accounts. Specifically, we recorded skin-conductance responses to spiders and fearful faces, along with subsequent preferences for novel neutral faces during visually aware and unaware states. Fearful faces increased skin-conductance responses comparably in both stimulus-aware and stimulus-unaware conditions. Yet only when visual awareness was precluded did skin-conductance responses to fearful faces predict decreased likability of neutral faces. These findings suggest a regulatory role for conscious awareness in breaking otherwise automatic associations between physiological reactivity and evaluative emotional responses.
East Europe Report, Scientific Affairs, Number 749
1982-07-23
Scientific Associate A. Andreev, Corresponding Member D. Shopov , Scientific Associate B. Kunev, V. Idakiev and A. Bankova. A collective at the Economic...operational systems — manual, automatic and remote control; control system — G P oSL ?nP™ y measurement ~ automatic and in percentage figures; power
Automatized Assessment of Protective Group Reactivity: A Step Toward Big Reaction Data Analysis.
Lin, Arkadii I; Madzhidov, Timur I; Klimchuk, Olga; Nugmanov, Ramil I; Antipin, Igor S; Varnek, Alexandre
2016-11-28
We report a new method to assess protective groups (PGs) reactivity as a function of reaction conditions (catalyst, solvent) using raw reaction data. It is based on an intuitive similarity principle for chemical reactions: similar reactions proceed under similar conditions. Technically, reaction similarity can be assessed using the Condensed Graph of Reaction (CGR) approach representing an ensemble of reactants and products as a single molecular graph, i.e., as a pseudomolecule for which molecular descriptors or fingerprints can be calculated. CGR-based in-house tools were used to process data for 142,111 catalytic hydrogenation reactions extracted from the Reaxys database. Our results reveal some contradictions with famous Greene's Reactivity Charts based on manual expert analysis. Models developed in this study show high accuracy (ca. 90%) for predicting optimal experimental conditions of protective group deprotection.
Automatic Processing of Reactive Polymers
NASA Technical Reports Server (NTRS)
Roylance, D.
1985-01-01
A series of process modeling computer codes were examined. The codes use finite element techniques to determine the time-dependent process parameters operative during nonisothermal reactive flows such as can occur in reaction injection molding or composites fabrication. The use of these analytical codes to perform experimental control functions is examined; since the models can determine the state of all variables everywhere in the system, they can be used in a manner similar to currently available experimental probes. A small but well instrumented reaction vessel in which fiber-reinforced plaques are cured using computer control and data acquisition was used. The finite element codes were also extended to treat this particular process.
An Automatic Networking and Routing Algorithm for Mesh Network in PLC System
NASA Astrophysics Data System (ADS)
Liu, Xiaosheng; Liu, Hao; Liu, Jiasheng; Xu, Dianguo
2017-05-01
Power line communication (PLC) is considered to be one of the best communication technologies in smart grid. However, the topology of low voltage distribution network is complex, meanwhile power line channel has characteristics of time varying and attenuation, which lead to the unreliability of power line communication. In this paper, an automatic networking and routing algorithm is introduced which can be adapted to the "blind state" topology. The results of simulation and test show that the scheme is feasible, the routing overhead is small, and the load balance performance is good, which can achieve the establishment and maintenance of network quickly and effectively. The scheme is of great significance to improve the reliability of PLC.
Lessing, Paul A.; Zuppero, Anthony C.
1997-06-24
A miniature power source assembly capable of providing portable electricity is provided. A preferred embodiment of the power source assembly employing a fuel tank, fuel pump and control, air pump, heat management system, power chamber, power conditioning and power storage. The power chamber utilizes a ceramic fuel cell to produce the electricity. Incoming hydro carbon fuel is automatically reformed within the power chamber. Electrochemical combustion of hydrogen then produces electricity.
NASA Astrophysics Data System (ADS)
Laithwaite, E. R.; Kuznetsov, S. B.
1980-09-01
A new technique of continuously generating reactive power from the stator of a brushless induction machine is conceived and tested on a 10-kw linear machine and on 35 and 150 rotary cage motors. An auxiliary magnetic wave traveling at rotor speed is artificially created by the space-transient attributable to the asymmetrical stator winding. At least two distinct windings of different pole-pitch must be incorporated. This rotor wave drifts in and out of phase repeatedly with the stator MMF wave proper and the resulting modulation of the airgap flux is used to generate reactive VA apart from that required for magnetization or leakage flux. The VAR generation effect increases with machine size, and leading power factor operation of the entire machine is viable for large industrial motors and power system induction generators.
Reactive power compensating system
Williams, Timothy J.; El-Sharkawi, Mohamed A.; Venkata, Subrahmanyam S.
1987-01-01
The reactive power of an induction machine is compensated by providing fixed capacitors on each phase line for the minimum compensation required, sensing the current on one line at the time its voltage crosses zero to determine the actual compensation required for each phase, and selecting switched capacitors on each line to provide the balance of the compensation required.
78 FR 72673 - Zero Rate Reactive Power Rate Schedules; Notice of Staff Workshop
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-03
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. AD14-1-000] Zero Rate Reactive Power Rate Schedules; Notice of Staff Workshop This notice establishes the location and date for... located at: https://www.ferc.gov/whats-new/registration/zero-rate-12-11-13-form.asp . The workshop will...
Code of Federal Regulations, 2013 CFR
2013-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-1 General. This subpart contains requirements applicable to...
Code of Federal Regulations, 2014 CFR
2014-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-1 General. This subpart contains requirements applicable to...
Code of Federal Regulations, 2010 CFR
2010-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-1 General. This subpart contains requirements applicable to...
Code of Federal Regulations, 2011 CFR
2011-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-1 General. This subpart contains requirements applicable to...
Code of Federal Regulations, 2012 CFR
2012-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-1 General. This subpart contains requirements applicable to...
Iakimova, L D
1997-01-01
The article touches upon hygienic problems associated with mechanization and automation of major hydroelectric power stations. The authors present criteria to evaluate work conditions of the main occupations participating in the technologic process of hydroelectric power stations.
Long Term Suboxone™ Emotional Reactivity As Measured by Automatic Detection in Speech
Hill, Edward; Han, David; Dumouchel, Pierre; Dehak, Najim; Quatieri, Thomas; Moehs, Charles; Oscar-Berman, Marlene; Giordano, John; Simpatico, Thomas; Blum, Kenneth
2013-01-01
Addictions to illicit drugs are among the nation’s most critical public health and societal problems. The current opioid prescription epidemic and the need for buprenorphine/naloxone (Suboxone®; SUBX) as an opioid maintenance substance, and its growing street diversion provided impetus to determine affective states (“true ground emotionality”) in long-term SUBX patients. Toward the goal of effective monitoring, we utilized emotion-detection in speech as a measure of “true” emotionality in 36 SUBX patients compared to 44 individuals from the general population (GP) and 33 members of Alcoholics Anonymous (AA). Other less objective studies have investigated emotional reactivity of heroin, methadone and opioid abstinent patients. These studies indicate that current opioid users have abnormal emotional experience, characterized by heightened response to unpleasant stimuli and blunted response to pleasant stimuli. However, this is the first study to our knowledge to evaluate “true ground” emotionality in long-term buprenorphine/naloxone combination (Suboxone™). We found in long-term SUBX patients a significantly flat affect (p<0.01), and they had less self-awareness of being happy, sad, and anxious compared to both the GP and AA groups. We caution definitive interpretation of these seemingly important results until we compare the emotional reactivity of an opioid abstinent control using automatic detection in speech. These findings encourage continued research strategies in SUBX patients to target the specific brain regions responsible for relapse prevention of opioid addiction. PMID:23874860
Tutorial: Reactive high power impulse magnetron sputtering (R-HiPIMS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anders, André
High Power Impulse Magnetron Sputtering (HiPIMS) is a coating technology that combines magnetron sputtering with pulsed power concepts. Furthermore, by applying power in pulses of high amplitude and a relatively low duty cycle, large fractions of sputtered atoms and near-target gases are ionized. In contrast to conventional magnetron sputtering, HiPIMS is characterized by self-sputtering or repeated gas recycling for high and low sputter yield materials, respectively, and both for most intermediate materials. The dense plasma in front of the target has the dual function of sustaining the discharge and providing plasma-assistance to film growth, affecting the microstructure of growing films.more » Many technologically interesting thin films are compound films, which are composed of one or more metals and a reactive gas, most often oxygen or nitrogen. When reactive gas is added, non-trivial consequences arise for the system because the target may become “poisoned,” i.e., a compound layer forms on the target surface affecting the sputtering yield and the yield of secondary electron emission and thereby all other parameters. It is emphasized that the target state depends not only on the reactive gas' partial pressure (balanced via gas flow and pumping) but also on the ion flux to the target, which can be controlled by pulse parameters. This is a critical technological opportunity for reactive HiPIMS (R-HiPIMS). The scope of this tutorial is focused on plasma processes and mechanisms of operation and only briefly touches upon film properties. It introduces R-HiPIMS in a systematic, step-by-step approach by covering sputtering, magnetron sputtering, reactive magnetron sputtering, pulsed reactive magnetron sputtering, HiPIMS, and finally R-HiPIMS. The tutorial is concluded by considering variations of R-HiPIMS known as modulated pulsed power magnetron sputtering and deep-oscillation magnetron sputtering and combinations of R-HiPIMS with superimposed dc magnetron sputtering.« less
Tutorial: Reactive high power impulse magnetron sputtering (R-HiPIMS)
Anders, André
2017-03-21
High Power Impulse Magnetron Sputtering (HiPIMS) is a coating technology that combines magnetron sputtering with pulsed power concepts. Furthermore, by applying power in pulses of high amplitude and a relatively low duty cycle, large fractions of sputtered atoms and near-target gases are ionized. In contrast to conventional magnetron sputtering, HiPIMS is characterized by self-sputtering or repeated gas recycling for high and low sputter yield materials, respectively, and both for most intermediate materials. The dense plasma in front of the target has the dual function of sustaining the discharge and providing plasma-assistance to film growth, affecting the microstructure of growing films.more » Many technologically interesting thin films are compound films, which are composed of one or more metals and a reactive gas, most often oxygen or nitrogen. When reactive gas is added, non-trivial consequences arise for the system because the target may become “poisoned,” i.e., a compound layer forms on the target surface affecting the sputtering yield and the yield of secondary electron emission and thereby all other parameters. It is emphasized that the target state depends not only on the reactive gas' partial pressure (balanced via gas flow and pumping) but also on the ion flux to the target, which can be controlled by pulse parameters. This is a critical technological opportunity for reactive HiPIMS (R-HiPIMS). The scope of this tutorial is focused on plasma processes and mechanisms of operation and only briefly touches upon film properties. It introduces R-HiPIMS in a systematic, step-by-step approach by covering sputtering, magnetron sputtering, reactive magnetron sputtering, pulsed reactive magnetron sputtering, HiPIMS, and finally R-HiPIMS. The tutorial is concluded by considering variations of R-HiPIMS known as modulated pulsed power magnetron sputtering and deep-oscillation magnetron sputtering and combinations of R-HiPIMS with superimposed dc magnetron sputtering.« less
Tutorial: Reactive high power impulse magnetron sputtering (R-HiPIMS)
NASA Astrophysics Data System (ADS)
Anders, André
2017-05-01
High Power Impulse Magnetron Sputtering (HiPIMS) is a coating technology that combines magnetron sputtering with pulsed power concepts. By applying power in pulses of high amplitude and a relatively low duty cycle, large fractions of sputtered atoms and near-target gases are ionized. In contrast to conventional magnetron sputtering, HiPIMS is characterized by self-sputtering or repeated gas recycling for high and low sputter yield materials, respectively, and both for most intermediate materials. The dense plasma in front of the target has the dual function of sustaining the discharge and providing plasma-assistance to film growth, affecting the microstructure of growing films. Many technologically interesting thin films are compound films, which are composed of one or more metals and a reactive gas, most often oxygen or nitrogen. When reactive gas is added, non-trivial consequences arise for the system because the target may become "poisoned," i.e., a compound layer forms on the target surface affecting the sputtering yield and the yield of secondary electron emission and thereby all other parameters. It is emphasized that the target state depends not only on the reactive gas' partial pressure (balanced via gas flow and pumping) but also on the ion flux to the target, which can be controlled by pulse parameters. This is a critical technological opportunity for reactive HiPIMS (R-HiPIMS). The scope of this tutorial is focused on plasma processes and mechanisms of operation and only briefly touches upon film properties. It introduces R-HiPIMS in a systematic, step-by-step approach by covering sputtering, magnetron sputtering, reactive magnetron sputtering, pulsed reactive magnetron sputtering, HiPIMS, and finally R-HiPIMS. The tutorial is concluded by considering variations of R-HiPIMS known as modulated pulsed power magnetron sputtering and deep-oscillation magnetron sputtering and combinations of R-HiPIMS with superimposed dc magnetron sputtering.
NASA Astrophysics Data System (ADS)
Hamaguchi, Satoshi
2013-07-01
Plasmas whose gas temperatures are close to room temperature may be generated in ambient air or a gas at atmospheric pressure with the use of low-frequency high voltage or low-power radio-frequency (RF) or microwave power applied to electrodes. Such plasmas can serve as a powerful source of free radicals and/or chemically reactive species that arise from atoms and molecules of the ambient gas. Recently use of such plasmas for medical purposes has attracted much attention as they can be implemented in possible medical devices that can cause blood coagulation, heal wounds, facilitate angiogenesis, sterilize surgical devices as well as living tissues without harming healthy cells, and selectively inactivate cancer cells. Especially of interest among reactive species generated by atmospheric-pressure plasmas (APP) are reactive oxygen species (ROS) and reactive nitrogen species (RNS) that are generated in liquid phase. Since most living tissues and cells are immersed in liquids (such as blood or culture media), reactive species generated by APPs in the gas phase are transported to the liquid phase and possibly converted to different types of reactive species therein before causing some influence on the tissues or cells. In this study, the rate equations are solved to evaluate concentrations of various reactive species in pure water that are originated by plasma reactions in atmosphere and possible effects of such species (including ROS/RNS) on living tissues and cells are discussed.
Use of DFIWG for Improvement of Voltage Stability Condition of a Power System
NASA Astrophysics Data System (ADS)
Hazarika, Durlav; Das, Ranjay
2017-12-01
This paper describes a method for improvement of voltage stability condition of a multi-bus power system by regulating reactive power generation at a Doubly Fed Induction Wind Generator (DFIWG). For this purpose, sensitivity relation between changes in voltage stability index at a bus with respect to change in reactive power generation of the DFIWG is derived. This relation is used to determine the required amount of change in rotor current of the DFIWG to improve the voltage stability index of the bus.
DOE Office of Scientific and Technical Information (OSTI.GOV)
March-Leuba, JA
2002-01-15
This report describes the tasks performed and the progress made during Phase 2 of the DOE-NERI project number 99-119 entitled Automatic Development of Highly Reliable Control Architecture for Future Nuclear Power Plants. This project is a collaboration effort between the Oak Ridge National Laboratory (ORNL), The University of Tennessee, Knoxville (UTK) and the North Carolina State University (NCSU). ORNL is the lead organization and is responsible for the coordination and integration of all work.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whealton, John H.; Hanson, Gregory R.; Storey, John M.
This patent application describes a method and apparatus of exhaust gas remediation that enhance the reactivity of the material catalysts found within catalytic converters of cars, trucks, and power stations.
Control of Solar Power Plants Connected Grid with Simple Calculation Method on Residential Homes
NASA Astrophysics Data System (ADS)
Kananda, Kiki; Nazir, Refdinal
2017-12-01
One of the most compatible renewable energy in all regions to apply is solar energy. Solar power plants can be built connected to existing or stand-alone power grids. In assisting the residential electricity in which there is a power grid, then a small scale solar energy power plants is very appropriate. However, the general constraint of solar energy power plants is still low in terms of efficiency. Therefore, this study will explain how to control the power of solar power plants more optimally, which is expected to reactive power to zero to raise efficiency. This is a continuation of previous research using Newton Rapshon control method. In this study we introduce a simple method by using ordinary mathematical calculations of solar-related equations. In this model, 10 PV modules type of ND T060M1 with a 60 Wp capacity are used. The calculations performed using MATLAB Simulink provide excellent value. For PCC voltage values obtained a stable quantity of approximately 220 V. At a maximum irradiation condition of 1000 W / m2, the reactive power value of Q solar generating system maximum 20.48 Var and maximum active power of 417.5 W. In the condition of lower irradiation, value of reactive power Q almost close to zero 0.77Var. This simple mathematical method can provide excellent quality control power values.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the main reservoir air pressure. The operating valve handle for such connection shall be conveniently... automatically prevent loss of pressure in event of failure of the main reservoir air pressure. (c) Power reverse... automatically prevent the loss of pressure in the event of a failure of main air pressure and have storage...
Code of Federal Regulations, 2011 CFR
2011-10-01
... the main reservoir air pressure. The operating valve handle for such connection shall be conveniently... automatically prevent loss of pressure in event of failure of the main reservoir air pressure. (c) Power reverse... automatically prevent the loss of pressure in the event of a failure of main air pressure and have storage...
Code of Federal Regulations, 2012 CFR
2012-10-01
... the main reservoir air pressure. The operating valve handle for such connection shall be conveniently... automatically prevent loss of pressure in event of failure of the main reservoir air pressure. (c) Power reverse... automatically prevent the loss of pressure in the event of a failure of main air pressure and have storage...
Code of Federal Regulations, 2013 CFR
2013-10-01
... the main reservoir air pressure. The operating valve handle for such connection shall be conveniently... automatically prevent loss of pressure in event of failure of the main reservoir air pressure. (c) Power reverse... automatically prevent the loss of pressure in the event of a failure of main air pressure and have storage...
Automatic 3D power line reconstruction of multi-angular imaging power line inspection system
NASA Astrophysics Data System (ADS)
Zhang, Wuming; Yan, Guangjian; Wang, Ning; Li, Qiaozhi; Zhao, Wei
2007-06-01
We develop a multi-angular imaging power line inspection system. Its main objective is to monitor the relative distance between high voltage power line and around objects, and alert if the warning threshold is exceeded. Our multi-angular imaging power line inspection system generates DSM of the power line passage, which comprises ground surface and ground objects, for example trees and houses, etc. For the purpose of revealing the dangerous regions, where ground objects are too close to the power line, 3D power line information should be extracted at the same time. In order to improve the automation level of extraction, reduce labour costs and human errors, an automatic 3D power line reconstruction method is proposed and implemented. It can be achieved by using epipolar constraint and prior knowledge of pole tower's height. After that, the proper 3D power line information can be obtained by space intersection using found homologous projections. The flight experiment result shows that the proposed method can successfully reconstruct 3D power line, and the measurement accuracy of the relative distance satisfies the user requirement of 0.5m.
Rensing, N; Westermann, A; Möller, D; von Piekartz, H
2015-12-01
Studies have shown changes in the technical and physical demands in modern handball. The game has increased considerably in speed, power and dynamics. Jump training has, therefore, become ever more important in the training of the athletes. These developments contribute to the fact that handball is now one of the most injury-prone types of sport, with the lower extremities being most frequently affected. Reactive jump training is not only used in training by now, but also increasingly in injury prevention. The aim of this study was to investigate the effectiveness of reactive jump training with handball players. 21 regional league handball players were randomly divided into an intervention group (n = 12) and a control group (n = 9). The intervention group completed a six-week reactive jump training programme while the control group went through a non-specific training programme. Jump height (squat and counter movement jump), isokinetic and isometric maximum power as well as muscle activity served as measuring parameters. A comparison of the intervention and control groups revealed that the reactive jump training led to significant improvements in jump height. The isometric and isokinetic maximum power measurements and the electromyographic activities of the triceps surae muscle demonstrated an improvement in the values within the intervention group. However, this improvement was not significant compared with the control group. Likewise both jumps correlated with the muscle activity of the soleus muscle as shown by electromyography. A moderate correlation was noticed between the isokinetic maximum power measurement and the electromyographic activity of the soleus and gastrocnemius medialis muscles. Furthermore, the correlations of the isometric and isokinetic maximum power meas-urements resulted in a strong correlation coefficient. This study revealed a significant increase in jump height after reactive jump training. There was no significant difference in power development between the two groups. However, we were able to demonstrate correlations which would make it seem reasonable and interesting to investigate the question more closely. An interesting field of research could be the question of the effectiveness of reactive jump training in the areas of rehabilitation and injury prevention. © Georg Thieme Verlag KG Stuttgart · New York.
Mighty Metaphors: Behavioral and ERP Evidence that Power Shifts Attention on a Vertical Dimension
ERIC Educational Resources Information Center
Zanolie, Kiki; van Dantzig, Saskia; Boot, Inge; Wijnen, Jasper; Schubert, Thomas W.; Giessner, Steffen R.; Pecher, Diane
2012-01-01
Thinking about the abstract concept power may automatically activate the spatial up-down image schema ("powerful up"; "powerless down") and consequently direct spatial attention to the image schema-congruent location. Participants indicated whether a word represented a powerful or powerless person (e.g. "king" or "servant"). Following each…
Solar-Powered Water Distillation
NASA Technical Reports Server (NTRS)
Menninger, F. J.; Elder, R. J.
1985-01-01
Solar-powered still produces pure water at rate of 6,000 gallons per year. Still fully automatic and gravity-fed. Only outside electric power is timer clock and solenoid-operated valve. Still saves $5,000 yearly in energy costs and pays for itself in 3 1/2 years.
47 CFR 74.636 - Power limitations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... equivalent isotropically radiated power (EIRP), as referenced to an isotropic radiator, exceed the values... renewal. (b) The EIRP of transmitters that use Automatic Transmitter Power Control (ATPC) shall not exceed the EIRP specified on the station authorization. The EIRP of non-ATPC transmitters shall be maintained...
47 CFR 78.101 - Power limitations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... communications desired. In no event shall the average transmitter power or equivalent isotropically radiated... that use Automatic Transmitter Power Control (ATPC) shall not exceed the EIRP specified on the station authorization. The EIRP of non-ATPC transmitters shall be maintained as near as practicable to the EIRP...
47 CFR 78.101 - Power limitations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... communications desired. In no event shall the average transmitter power or equivalent isotropically radiated... that use Automatic Transmitter Power Control (ATPC) shall not exceed the EIRP specified on the station authorization. The EIRP of non-ATPC transmitters shall be maintained as near as practicable to the EIRP...
47 CFR 74.636 - Power limitations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... equivalent isotropically radiated power (EIRP), as referenced to an isotropic radiator, exceed the values... renewal. (b) The EIRP of transmitters that use Automatic Transmitter Power Control (ATPC) shall not exceed the EIRP specified on the station authorization. The EIRP of non-ATPC transmitters shall be maintained...
NASA Technical Reports Server (NTRS)
Fox, T. A.
1973-01-01
An experimental reflector reactivity study was made with a compact cylindrical reactor using a uranyl fluoride - water fuel solution. The reactor was axially unreflected and radially reflected with segments of molybdenum. The reflector segments were displaced incrementally in both the axial and radial dimensions, and the shutdown of each configuration was measured by using the pulsed-neutron source technique. The reactivity effects for axial and radial displacement of reflector segments are tabulated separately and compared. The experiments provide data for control-system studies of compact-space-power-reactor concepts.
Reactive power optimization strategy considering analytical impedance ratio
NASA Astrophysics Data System (ADS)
Wu, Zhongchao; Shen, Weibing; Liu, Jinming; Guo, Maoran; Zhang, Shoulin; Xu, Keqiang; Wang, Wanjun; Sui, Jinlong
2017-05-01
In this paper, considering the traditional reactive power optimization cannot realize the continuous voltage adjustment and voltage stability, a dynamic reactive power optimization strategy is proposed in order to achieve both the minimization of network loss and high voltage stability with wind power. Due to the fact that wind power generation is fluctuant and uncertain, electrical equipments such as transformers and shunt capacitors may be operated frequently in order to achieve minimization of network loss, which affect the lives of these devices. In order to solve this problem, this paper introduces the derivation process of analytical impedance ratio based on Thevenin equivalent. Thus, the multiple objective function is proposed to minimize the network loss and analytical impedance ratio. Finally, taking the improved IEEE 33-bus distribution system as example, the result shows that the movement of voltage control equipment has been reduced and network loss increment is controlled at the same time, which proves the applicable value of this strategy.
NASA Astrophysics Data System (ADS)
Melville, R.; Stillinger, A.; Gerrard, A.; Weatherwax, A.
2014-04-01
The need to provide power to unmanned instrumentation over the course of an entire year on the Antarctic plateau presents a large number of engineering and logistical challenges. Designs formulated in ideal laboratory environments often fail in the Antarctic due to the harsh operating conditions, and field experience is necessary to achieve year-round operation in the 100 W power range. In this paper we present our current power design for the Automatic Geophysical Observatories; a design based on over two decades of experience on the ice and allows for relatively continuous operation at the aforementioned power level. We also discuss our various implementation methods, both failures and successes, in an effort assist other unmanned deployments on the ice.
Melville, R; Stillinger, A; Gerrard, A; Weatherwax, A
2014-04-01
The need to provide power to unmanned instrumentation over the course of an entire year on the Antarctic plateau presents a large number of engineering and logistical challenges. Designs formulated in ideal laboratory environments often fail in the Antarctic due to the harsh operating conditions, and field experience is necessary to achieve year-round operation in the 100 W power range. In this paper we present our current power design for the Automatic Geophysical Observatories; a design based on over two decades of experience on the ice and allows for relatively continuous operation at the aforementioned power level. We also discuss our various implementation methods, both failures and successes, in an effort assist other unmanned deployments on the ice.
NASA Astrophysics Data System (ADS)
Verma, H. K.; Mafidar, P.
2013-09-01
In view of growing concern towards environment, power system engineers are forced to generate quality green energy. Hence the economic dispatch (ED) aims at the power generation to meet the load demand at minimum fuel cost with environmental and voltage constraints along with essential constraints on real and reactive power. The emission control which reduces the negative impact on environment is achieved by including the additional constraints in ED problem. Presently, the power system mostly operates near its stability limits, therefore with increased demand the system faces voltage problem. The bus voltages are brought within limit in the present work by placement of static var compensator (SVC) at weak bus which is identified from bus participation factor. The optimal size of SVC is determined by univariate search method. This paper presents the use of Teaching Learning based Optimization (TLBO) algorithm for voltage stable environment friendly ED problem with real and reactive power constraints. The computational effectiveness of TLBO is established through test results over particle swarm optimization (PSO) and Big Bang-Big Crunch (BB-BC) algorithms for the ED problem.
RF Energy Harvesting Peel-and-Stick Sensors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lalau-Keraly, Christopher; Schwartz, David; Daniel, George
PARC, a Xerox Company, is developing a low-cost system of peel-and-stick wireless sensors that will enable widespread building environment sensor deployment with the potential to deliver up to 30% energy savings. The system is embodied by a set of RF hubs that provide power to the automatically located sensor nodes, and relays data wirelessly to the building management system (BMS). The sensor nodes are flexible electronic labels powered by rectified RF energy transmitted by a RF hub and can contain multiple printed and conventional sensors. The system design overcomes limitations in wireless sensors related to power delivery, lifetime, and costmore » by eliminating batteries and photovoltaic devices. The sensor localization is performed automatically by the inclusion of a programmable multidirectional antenna array in the RF hub. Comparison of signal strengths when the RF beam is swept allows for sensor localization, further reducing installation effort and enabling automatic recommissioning of sensors that have been relocated, overcoming a significant challenge in building operations. PARC has already demonstrated wireless power and temperature data transmission up to a distance of 20m with a duty cycle less than a minute between measurements, using power levels well within the FCC regulation limits in the 902-928 MHz ISM band. The sensor’s RF energy harvesting antenna dimensions was less than 5cmx9cm, demonstrating the possibility of small form factor for the sensor nodes.« less
Design of Automatic Intensity Varying Smart Street Lighting System
NASA Astrophysics Data System (ADS)
Gupta, Ashutosh; Gupta, Shipra
2017-08-01
The paper is proposed with an aim of power conservation. In this era of development, it is essential to develop a streetlight that turns on and off automatically without human interference. To achieve this light sensor have been placed in each panel which turns the street light on and off automatically. For energy conservation cool-white LED’s have been used in street light panel and dimmer modules have been installed which changes the intensity of the streetlight depending on the darkness.
NASA Astrophysics Data System (ADS)
Ro, Kyoungsoo
The study started with the requirement that a photovoltaic (PV) power source should be integrated with other supplementary power sources whether it operates in a stand-alone or grid-connected mode. First, fuel cells for a backup of varying PV power were compared in detail with batteries and were found to have more operational benefits. Next, maximizing performance of a grid-connected PV-fuel cell hybrid system by use of a two-loop controller was discussed. One loop is a neural network controller for maximum power point tracking, which extracts maximum available solar power from PV arrays under varying conditions of insolation, temperature, and system load. A real/reactive power controller (RRPC) is the other loop. The RRPC meets the system's requirement for real and reactive powers by controlling incoming fuel to fuel cell stacks as well as switching control signals to a power conditioning subsystem. The RRPC is able to achieve more versatile control of real/reactive powers than the conventional power sources since the hybrid power plant does not contain any rotating mass. Results of time-domain simulations prove not only effectiveness of the proposed computer models of the two-loop controller, but also their applicability for use in transient stability analysis of the hybrid power plant. Finally, environmental evaluation of the proposed hybrid plant was made in terms of plant's land requirement and lifetime COsb2 emissions, and then compared with that of the conventional fossil-fuel power generating forms.
Code of Federal Regulations, 2010 CFR
2010-07-01
... using electrically released brakes shall be constructed so that the brakes cannot be released until power is applied, and so that the brakes are automatically engaged if the power fails or the operating... the operation of any power conveyor requires personnel to work in the immediate vicinity of the...
46 CFR 112.25-3 - Normal source for emergency loads.
Code of Federal Regulations, 2014 CFR
2014-10-01
....25-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-3 Normal source for...
46 CFR 112.25-3 - Normal source for emergency loads.
Code of Federal Regulations, 2013 CFR
2013-10-01
....25-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-3 Normal source for...
46 CFR 112.25-10 - Transfer of emergency loads.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-10 Transfer of emergency loads. (a) When...
46 CFR 112.25-10 - Transfer of emergency loads.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-10 Transfer of emergency loads. (a) When...
46 CFR 112.25-10 - Transfer of emergency loads.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-10 Transfer of emergency loads. (a) When...
46 CFR 112.25-10 - Transfer of emergency loads.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-10 Transfer of emergency loads. (a) When...
46 CFR 112.25-10 - Transfer of emergency loads.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-10 Transfer of emergency loads. (a) When...
46 CFR 112.25-3 - Normal source for emergency loads.
Code of Federal Regulations, 2010 CFR
2010-10-01
....25-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-3 Normal source for...
46 CFR 112.25-3 - Normal source for emergency loads.
Code of Federal Regulations, 2011 CFR
2011-10-01
....25-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-3 Normal source for...
46 CFR 112.25-3 - Normal source for emergency loads.
Code of Federal Regulations, 2012 CFR
2012-10-01
....25-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-3 Normal source for...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Senyagin, Yu.V.; Sop'yanik, V.Kh.; Oreshkin, Yu.A.
1982-11-01
Increasing the operational reliability of power generating equipment is linked to the storage and systematization of objective information pertaining to the causes and progress of emergencies occurring in the equipment. Current methods for receiving such information at thermal power plants are discussed.
46 CFR 129.440 - Emergency lighting.
Code of Federal Regulations, 2013 CFR
2013-10-01
... working (machinery) spaces below the main deck. (b) The emergency lighting required by paragraph (a) of... with a single source of power for emergency lighting, it must have individual battery-powered lighting that is— (1) Automatically actuated upon loss of normal power; (2) Not readily portable; (3) Connected...
46 CFR 129.440 - Emergency lighting.
Code of Federal Regulations, 2014 CFR
2014-10-01
... working (machinery) spaces below the main deck. (b) The emergency lighting required by paragraph (a) of... with a single source of power for emergency lighting, it must have individual battery-powered lighting that is— (1) Automatically actuated upon loss of normal power; (2) Not readily portable; (3) Connected...
46 CFR 129.440 - Emergency lighting.
Code of Federal Regulations, 2012 CFR
2012-10-01
... working (machinery) spaces below the main deck. (b) The emergency lighting required by paragraph (a) of... with a single source of power for emergency lighting, it must have individual battery-powered lighting that is— (1) Automatically actuated upon loss of normal power; (2) Not readily portable; (3) Connected...
46 CFR 129.440 - Emergency lighting.
Code of Federal Regulations, 2011 CFR
2011-10-01
... working (machinery) spaces below the main deck. (b) The emergency lighting required by paragraph (a) of... with a single source of power for emergency lighting, it must have individual battery-powered lighting that is— (1) Automatically actuated upon loss of normal power; (2) Not readily portable; (3) Connected...
Silvestrini, Nicolas
2017-09-01
Numerous studies have assessed cardiovascular (CV) reactivity as a measure of effort mobilization during cognitive tasks. However, psychological and neural processes underlying effort-related CV reactivity are still relatively unclear. Previous research reliably found that CV reactivity during cognitive tasks is mainly determined by one region of the brain, the dorsal anterior cingulate cortex (dACC), and that this region is systematically engaged during cognitively demanding tasks. The present integrative approach builds on the research on cognitive control and its brain correlates that shows that dACC function can be related to conflict monitoring and integration of information related to task difficulty and success importance-two key variables in determining effort mobilization. In contrast, evidence also indicates that executive cognitive functioning is processed in more lateral regions of the prefrontal cortex. The resulting model suggests that, when automatic cognitive processes are insufficient to sustain behavior, the dACC determines the amount of required and justified effort according to task difficulty and success importance, which leads to proportional adjustments in CV reactivity and executive cognitive functioning. These propositions are discussed in relation to previous findings on effort-related CV reactivity and cognitive performance, new predictions for future studies, and relevance for other self-regulatory processes. Copyright © 2016 Elsevier B.V. All rights reserved.
Automatic Electronic Oxygen Supply
Ford, Patricia; Hoodless, D. J.
1971-01-01
An automatic electronic oxygen system has been devised to supply an intensive care unit with a “fail-safe” supply of continuous oxygen. All parts of the system are fitted with alarms, as the oxygen powers gas-driven ventilators. Since the system is cheap it can be installed in hospitals where finance is limited. PMID:5278618
46 CFR 153.408 - Tank overflow control.
Code of Federal Regulations, 2010 CFR
2010-10-01
... automatic shutdown system must: (1) Be independent of one-another; and (2) Operate on loss of power. (c) The... lettering as specified for the warning sign in § 153.955. (e) A tank overflow alarm must be audible and... loading is controlled on the tankship. (f) The automatic shutdown system or tank overflow alarm must be...
46 CFR 153.408 - Tank overflow control.
Code of Federal Regulations, 2011 CFR
2011-10-01
... automatic shutdown system must: (1) Be independent of one-another; and (2) Operate on loss of power. (c) The... lettering as specified for the warning sign in § 153.955. (e) A tank overflow alarm must be audible and... loading is controlled on the tankship. (f) The automatic shutdown system or tank overflow alarm must be...
Automatic cryogenic liquid level controller is safe for use near combustible substances
NASA Technical Reports Server (NTRS)
Krejsa, M.
1966-01-01
Automatic mechanical liquid level controller that is independent of any external power sources is used with safety in the presence of combustibles. A gas filled capillary tube which leads from a pressurized chamber, is inserted into the cryogenic liquid reservoir and becomes a liquid level sensing element or probe.
14 CFR 23.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
... CATEGORY AIRPLANES Design and Construction Control Systems § 23.672 Stability augmentation and automatic... systems must not activate the control system. (b) The design of the stability augmentation system or of... thereof, or by overriding the failure by movement of the flight controls in the normal sense. (c) It must...
14 CFR 23.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2012 CFR
2012-01-01
... CATEGORY AIRPLANES Design and Construction Control Systems § 23.672 Stability augmentation and automatic... systems must not activate the control system. (b) The design of the stability augmentation system or of... thereof, or by overriding the failure by movement of the flight controls in the normal sense. (c) It must...
14 CFR 23.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2014 CFR
2014-01-01
... CATEGORY AIRPLANES Design and Construction Control Systems § 23.672 Stability augmentation and automatic... systems must not activate the control system. (b) The design of the stability augmentation system or of... thereof, or by overriding the failure by movement of the flight controls in the normal sense. (c) It must...
14 CFR 23.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2013 CFR
2013-01-01
... CATEGORY AIRPLANES Design and Construction Control Systems § 23.672 Stability augmentation and automatic... systems must not activate the control system. (b) The design of the stability augmentation system or of... thereof, or by overriding the failure by movement of the flight controls in the normal sense. (c) It must...
14 CFR 23.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2011 CFR
2011-01-01
... CATEGORY AIRPLANES Design and Construction Control Systems § 23.672 Stability augmentation and automatic... systems must not activate the control system. (b) The design of the stability augmentation system or of... thereof, or by overriding the failure by movement of the flight controls in the normal sense. (c) It must...
49 CFR 236.206 - Battery or power supply with respect to relay; location.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Battery or power supply with respect to relay..., AND APPLIANCES Automatic Block Signal Systems Standards § 236.206 Battery or power supply with respect to relay; location. The battery or power supply for each signal control relay circuit, where an open...
49 CFR 236.206 - Battery or power supply with respect to relay; location.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Battery or power supply with respect to relay..., AND APPLIANCES Automatic Block Signal Systems Standards § 236.206 Battery or power supply with respect to relay; location. The battery or power supply for each signal control relay circuit, where an open...
49 CFR 236.206 - Battery or power supply with respect to relay; location.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Battery or power supply with respect to relay..., AND APPLIANCES Automatic Block Signal Systems Standards § 236.206 Battery or power supply with respect to relay; location. The battery or power supply for each signal control relay circuit, where an open...
49 CFR 236.206 - Battery or power supply with respect to relay; location.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Battery or power supply with respect to relay..., AND APPLIANCES Automatic Block Signal Systems Standards § 236.206 Battery or power supply with respect to relay; location. The battery or power supply for each signal control relay circuit, where an open...
49 CFR 236.206 - Battery or power supply with respect to relay; location.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Battery or power supply with respect to relay..., AND APPLIANCES Automatic Block Signal Systems Standards § 236.206 Battery or power supply with respect to relay; location. The battery or power supply for each signal control relay circuit, where an open...
Deep Learning-Based Data Forgery Detection in Automatic Generation Control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Fengli; Li, Qinghua
Automatic Generation Control (AGC) is a key control system in the power grid. It is used to calculate the Area Control Error (ACE) based on frequency and tie-line power flow between balancing areas, and then adjust power generation to maintain the power system frequency in an acceptable range. However, attackers might inject malicious frequency or tie-line power flow measurements to mislead AGC to do false generation correction which will harm the power grid operation. Such attacks are hard to be detected since they do not violate physical power system models. In this work, we propose algorithms based on Neural Networkmore » and Fourier Transform to detect data forgery attacks in AGC. Different from the few previous work that rely on accurate load prediction to detect data forgery, our solution only uses the ACE data already available in existing AGC systems. In particular, our solution learns the normal patterns of ACE time series and detects abnormal patterns caused by artificial attacks. Evaluations on the real ACE dataset show that our methods have high detection accuracy.« less
NASA Technical Reports Server (NTRS)
Bragg-Sitton, Shannon M.; Forsbacka, Matthew
2004-01-01
For a compact, fast-spectrum reactor, reactivity feedback is dominated by core deformation at elevated temperature. Given the use of accurate deformation measurement techniques, it is possible to simulate nuclear feedback in non-nuclear electrically heated reactor tests. Implementation of simulated reactivity feedback in response to measured deflection is being tested at the NASA Marshall Space Flight Center Early Flight Fission Test Facility (EFF-TF). During tests of the SAFE-100 reactor prototype, core deflection was monitored using a high resolution camera. "virtual" reactivity feedback was accomplished by applying the results of Monte Carlo calculations (MCNPX) to core deflection measurements; the computational analysis was used to establish the reactivity worth of van'ous core deformations. The power delivered to the SAFE-100 prototype was then dusted accordingly via kinetics calculations, The work presented in this paper will demonstrate virtual reactivity feedback as core power was increased from 1 kilowatt(sub t), to 10 kilowatts(sub t), held approximately constant at 10 kilowatts (sub t), and then allowed to decrease based on the negative thermal reactivity coefficient.
Generic Software Architecture for Launchers
NASA Astrophysics Data System (ADS)
Carre, Emilien; Gast, Philippe; Hiron, Emmanuel; Leblanc, Alain; Lesens, David; Mescam, Emmanuelle; Moro, Pierre
2015-09-01
The definition and reuse of generic software architecture for launchers is not so usual for several reasons: the number of European launcher families is very small (Ariane 5 and Vega for these last decades); the real time constraints (reactivity and determinism needs) are very hard; low levels of versatility are required (implying often an ad hoc development of the launcher mission). In comparison, satellites are often built on a generic platform made up of reusable hardware building blocks (processors, star-trackers, gyroscopes, etc.) and reusable software building blocks (middleware, TM/TC, On Board Control Procedure, etc.). If some of these reasons are still valid (e.g. the limited number of development), the increase of the available CPU power makes today an approach based on a generic time triggered middleware (ensuring the full determinism of the system) and a centralised mission and vehicle management (offering more flexibility in the design and facilitating the long term maintenance) achievable. This paper presents an example of generic software architecture which could be envisaged for future launchers, based on the previously described principles and supported by model driven engineering and automatic code generation.
Reactive system verification case study: Fault-tolerant transputer communication
NASA Technical Reports Server (NTRS)
Crane, D. Francis; Hamory, Philip J.
1993-01-01
A reactive program is one which engages in an ongoing interaction with its environment. A system which is controlled by an embedded reactive program is called a reactive system. Examples of reactive systems are aircraft flight management systems, bank automatic teller machine (ATM) networks, airline reservation systems, and computer operating systems. Reactive systems are often naturally modeled (for logical design purposes) as a composition of autonomous processes which progress concurrently and which communicate to share information and/or to coordinate activities. Formal (i.e., mathematical) frameworks for system verification are tools used to increase the users' confidence that a system design satisfies its specification. A framework for reactive system verification includes formal languages for system modeling and for behavior specification and decision procedures and/or proof-systems for verifying that the system model satisfies the system specifications. Using the Ostroff framework for reactive system verification, an approach to achieving fault-tolerant communication between transputers was shown to be effective. The key components of the design, the decoupler processes, may be viewed as discrete-event-controllers introduced to constrain system behavior such that system specifications are satisfied. The Ostroff framework was also effective. The expressiveness of the modeling language permitted construction of a faithful model of the transputer network. The relevant specifications were readily expressed in the specification language. The set of decision procedures provided was adequate to verify the specifications of interest. The need for improved support for system behavior visualization is emphasized.
46 CFR 112.05-3 - Main-emergency bus-tie.
Code of Federal Regulations, 2010 CFR
2010-10-01
... emergency switchboard; (b) Be arranged to prevent parallel operation of an emergency power source with any other source of electric power, except for interlock systems for momentary transfer of loads; and (c) If arranged for feedback operation, open automatically upon overload of the emergency power source before the...
NASA Astrophysics Data System (ADS)
Osmanoglu, B.; Ozkan, C.; Sunar, F.
2013-10-01
After air strikes on July 14 and 15, 2006 the Jiyeh Power Station started leaking oil into the eastern Mediterranean Sea. The power station is located about 30 km south of Beirut and the slick covered about 170 km of coastline threatening the neighboring countries Turkey and Cyprus. Due to the ongoing conflict between Israel and Lebanon, cleaning efforts could not start immediately resulting in 12 000 to 15 000 tons of fuel oil leaking into the sea. In this paper we compare results from automatic and semi-automatic slick detection algorithms. The automatic detection method combines the probabilities calculated for each pixel from each image to obtain a joint probability, minimizing the adverse effects of atmosphere on oil spill detection. The method can readily utilize X-, C- and L-band data where available. Furthermore wind and wave speed observations can be used for a more accurate analysis. For this study, we utilize Envisat ASAR ScanSAR data. A probability map is generated based on the radar backscatter, effect of wind and dampening value. The semi-automatic algorithm is based on supervised classification. As a classifier, Artificial Neural Network Multilayer Perceptron (ANN MLP) classifier is used since it is more flexible and efficient than conventional maximum likelihood classifier for multisource and multi-temporal data. The learning algorithm for ANN MLP is chosen as the Levenberg-Marquardt (LM). Training and test data for supervised classification are composed from the textural information created from SAR images. This approach is semiautomatic because tuning the parameters of classifier and composing training data need a human interaction. We point out the similarities and differences between the two methods and their results as well as underlining their advantages and disadvantages. Due to the lack of ground truth data, we compare obtained results to each other, as well as other published oil slick area assessments.
Methods of computing steady-state voltage stability margins of power systems
Chow, Joe Hong; Ghiocel, Scott Gordon
2018-03-20
In steady-state voltage stability analysis, as load increases toward a maximum, conventional Newton-Raphson power flow Jacobian matrix becomes increasingly ill-conditioned so power flow fails to converge before reaching maximum loading. A method to directly eliminate this singularity reformulates the power flow problem by introducing an AQ bus with specified bus angle and reactive power consumption of a load bus. For steady-state voltage stability analysis, the angle separation between the swing bus and AQ bus can be varied to control power transfer to the load, rather than specifying the load power itself. For an AQ bus, the power flow formulation is only made up of a reactive power equation, thus reducing the size of the Jacobian matrix by one. This reduced Jacobian matrix is nonsingular at the critical voltage point, eliminating a major difficulty in voltage stability analysis for power system operations.
[Development of a Software for Automatically Generated Contours in Eclipse TPS].
Xie, Zhao; Hu, Jinyou; Zou, Lian; Zhang, Weisha; Zou, Yuxin; Luo, Kelin; Liu, Xiangxiang; Yu, Luxin
2015-03-01
The automatic generation of planning targets and auxiliary contours have achieved in Eclipse TPS 11.0. The scripting language autohotkey was used to develop a software for automatically generated contours in Eclipse TPS. This software is named Contour Auto Margin (CAM), which is composed of operational functions of contours, script generated visualization and script file operations. RESULTS Ten cases in different cancers have separately selected, in Eclipse TPS 11.0 scripts generated by the software could not only automatically generate contours but also do contour post-processing. For different cancers, there was no difference between automatically generated contours and manually created contours. The CAM is a user-friendly and powerful software, and can automatically generated contours fast in Eclipse TPS 11.0. With the help of CAM, it greatly save plan preparation time and improve working efficiency of radiation therapy physicists.
Automatic load sharing in inverter modules
NASA Technical Reports Server (NTRS)
Nagano, S.
1979-01-01
Active feedback loads transistor equally with little power loss. Circuit is suitable for balancing modular inverters in spacecraft, computer power supplies, solar-electric power generators, and electric vehicles. Current-balancing circuit senses differences between collector current for power transistor and average value of load currents for all power transistors. Principle is effective not only in fixed duty-cycle inverters but also in converters operating at variable duty cycles.
Automatic sleep stage classification using two-channel electro-oculography.
Virkkala, Jussi; Hasan, Joel; Värri, Alpo; Himanen, Sari-Leena; Müller, Kiti
2007-10-15
An automatic method for the classification of wakefulness and sleep stages SREM, S1, S2 and SWS was developed based on our two previous studies. The method is based on a two-channel electro-oculography (EOG) referenced to the left mastoid (M1). Synchronous electroencephalographic (EEG) activity in S2 and SWS was detected by calculating cross-correlation and peak-to-peak amplitude difference in the 0.5-6 Hz band between the two EOG channels. An automatic slow eye-movement (SEM) estimation was used to indicate wakefulness, SREM and S1. Beta power 18-30 Hz and alpha power 8-12 Hz was also used for wakefulness detection. Synchronous 1.5-6 Hz EEG activity and absence of large eye movements was used for S1 separation from SREM. Simple smoothing rules were also applied. Sleep EEG, EOG and EMG were recorded from 265 subjects. The system was tuned using data from 132 training subjects and then applied to data from 131 validation subjects that were different to the training subjects. Cohen's Kappa between the visual and the developed new automatic scoring in separating 30s wakefulness, SREM, S1, S2 and SWS epochs was substantial 0.62 with epoch by epoch agreement of 72%. With automatic subject specific alpha thresholds for offline applications results improved to 0.63 and 73%. The automatic method can be further developed and applied for ambulatory sleep recordings by using only four disposable, self-adhesive and self-applicable electrodes.
Traumatic asphyxia--fatal accident in an automatic revolving door.
Cortis, J; Falk, J; Rothschild, M A
2015-09-01
Due to continuing modernisation, the number of automatic doors in routine use, including powered revolving doors, has increased in recent years. Automatic revolving doors are found mostly in department stores, airports, railway stations and hospitals. Although safety arrangements and guidelines concerning the installation of automatic doors are in existence, their disregard in conjunction with obsolete or incorrect installation can lead to fatal accidents. In this report, a 19-month-old boy is described whose right arm was caught between the elements of an automatic revolving door. As a direct result of rescue attempts, the child's body was drawn further into the narrow gap between elements of the door. To get the boy's body out of the 4-cm-wide gap between the fixed outer wall of the revolving door and the revolving inner, back-up batteries had to be disconnected so as to stop the electrical motor powering the door. Cardiopulmonary resuscitation was begun immediately after the rescue but was unsuccessful; the child was declared dead at the hospital he was taken to. The cause of death was a combination of compression-related skull and brain injury together with thoracic compression. This case shows an outstanding example of the preventive aspect as a special task of forensic medicine. Additionally, it serves as a warning for the correct installation and use of automatic revolving doors. Even so, small children should not use these doors on their own, but only with an alert companion, so as to prevent further fatal accidents of this sort.
Kim, H C; Khanwilkar, P S; Bearnson, G B; Olsen, D B
1997-01-01
An automatic physiological control system for the actively filled, alternately pumped ventricles of the volumetrically coupled, electrohydraulic total artificial heart (EHTAH) was developed for long-term use. The automatic control system must ensure that the device: 1) maintains a physiological response of cardiac output, 2) compensates for an nonphysiological condition, and 3) is stable, reliable, and operates at a high power efficiency. The developed automatic control system met these requirements both in vitro, in week-long continuous mock circulation tests, and in vivo, in acute open-chested animals (calves). Satisfactory results were also obtained in a series of chronic animal experiments, including 21 days of continuous operation of the fully automatic control mode, and 138 days of operation in a manual mode, in a 159-day calf implant.
NASA Astrophysics Data System (ADS)
Hashemi-Dezaki, Hamed; Mohammadalizadeh-Shabestary, Masoud; Askarian-Abyaneh, Hossein; Rezaei-Jegarluei, Mohammad
2014-01-01
In electrical distribution systems, a great amount of power are wasting across the lines, also nowadays power factors, voltage profiles and total harmonic distortions (THDs) of most loads are not as would be desired. So these important parameters of a system play highly important role in wasting money and energy, and besides both consumers and sources are suffering from a high rate of distortions and even instabilities. Active power filters (APFs) are innovative ideas for solving of this adversity which have recently used instantaneous reactive power theory. In this paper, a novel method is proposed to optimize the allocation of APFs. The introduced method is based on the instantaneous reactive power theory in vectorial representation. By use of this representation, it is possible to asses different compensation strategies. Also, APFs proper placement in the system plays a crucial role in either reducing the losses costs and power quality improvement. To optimize the APFs placement, a new objective function has been defined on the basis of five terms: total losses, power factor, voltage profile, THD and cost. Genetic algorithm has been used to solve the optimization problem. The results of applying this method to a distribution network illustrate the method advantages.
Settlement of reactive power compensation in the light of white certificates
NASA Astrophysics Data System (ADS)
Zajkowski, Konrad
2017-10-01
The article discusses the problem of the determination of savings on active energy as a result of a reactive power compensation. Statutory guidance on the required energy audit to obtain white certificates in the European Union was followed. The analysis was made on the basis of the Polish Law. The paper presents a detailed analytical method and an estimation method taking into account the impact on the line, the transformer and the generator. According to the relevant guidelines in the European Union, the reduction of CO2 emissions by calculating the saving of active power should be determined. The detailed method and an estimation method proposed for the determination of savings on active energy as a result of the reactive power compensation carried out possess some errors and inconvenience. The detailed method requires knowledge of the network topology and a determination of reactive power Q at each point of the network. The estimation method of analysis is easy in execution, especially if the consumer of energy is the main or the most significant purchaser of electricity in the network. Unfortunately, this latter method can be used only for activities that do not require high computational accuracy. The results obtained by this method are approximate values that can be used for the calculation of economic indicators. The estimation method is suitable for determining the number of white certificates when a power audit concerns a recipient of electricity, the structure of which is a large number of divisions scattered at many different locations in the power system.
Design description of the Schuchuli Village photovoltaic power system
NASA Technical Reports Server (NTRS)
Ratajczak, A. F.; Vasicek, R. W.; Delombard, R.
1981-01-01
A stand alone photovoltaic (PV) power system for the village of Schuchuli (Gunsight), Arizona, on the Papago Indian Reservation is a limited energy, all 120 V (d.c.) system to which loads cannot be arbitrarily added and consists of a 3.5 kW (peak) PV array, 2380 ampere-hours of battery storage, an electrical equipment building, a 120 V (d.c.) electrical distribution network, and equipment and automatic controls to provide control power for pumping water into an existing water system; operating 15 refrigerators, a clothes washing machine, a sewing machine, and lights for each of the homes and communal buildings. A solar hot water heater supplies hot water for the washing machine and communal laundry. Automatic control systems provide voltage control by limiting the number of PV strings supplying power during system operation and battery charging, and load management for operating high priority at the expense of low priority loads as the main battery becomes depleted.
Design of electric control system for automatic vegetable bundling machine
NASA Astrophysics Data System (ADS)
Bao, Yan
2017-06-01
A design can meet the requirements of automatic bale food structure and has the advantages of simple circuit, and the volume is easy to enhance the electric control system of machine carrying bunch of dishes and low cost. The bundle of vegetable machine should meet the sensor to detect and control, in order to meet the control requirements; binding force can be adjusted by the button to achieve; strapping speed also can be adjusted, by the keys to set; sensors and mechanical line connection, convenient operation; can be directly connected with the plug, the 220V power supply can be connected to a power source; if, can work, by the transmission signal sensor, MCU to control the motor, drive and control procedures for small motor. The working principle of LED control circuit and temperature control circuit is described. The design of electric control system of automatic dish machine.
Real-time control of focused ultrasound heating based on rapid MR thermometry.
Vimeux, F C; De Zwart, J A; Palussiére, J; Fawaz, R; Delalande, C; Canioni, P; Grenier, N; Moonen, C T
1999-03-01
Real-time control of the heating procedure is essential for hyperthermia applications of focused ultrasound (FUS). The objective of this study is to demonstrate the feasibility of MRI-controlled FUS. An automatic control system was developed using a dedicated interface between the MR system control computer and the FUS wave generator. Two algorithms were used to regulate FUS power to maintain the focal point temperature at a desired level. Automatic control of FUS power level was demonstrated ex vivo at three target temperature levels (increase of 5 degrees C, 10 degrees C, and 30 degrees C above room temperature) during 30-minute hyperthermic periods. Preliminary in vivo results on rat leg muscle confirm that necrosis estimate, calculated on-line during FUS sonication, allows prediction of tissue damage. CONCLUSIONS. The feasibility of fully automatic FUS control based on MRI thermometry has been demonstrated.
Army gas-cooled reactor systems program. Preliminary design report off-normal scram system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bushnell, W.H.; Malmstrom, S.A.
1965-06-01
The maximum allowable ML-1 fuel element cladding (hot spot) temperature is established by ANTS 201 at 1750/sup 0/F. The existing ML-1 design makes no provision for automatic scram when this limit is reached. Operating experience has indicated a requirement for such an automatic system during plant startup and a revised hot spot envelope (generated during conceptual design of the scram system) established the desirability of extending this protection to operation at full power conditions. It was also determined that the scram system should include circuitry to initiate an automatic scram if reactor ..delta..T exceeded 450/sup 0/F (the limit established inmore » ANTS 201) and if reactor power exceeded 6 kw(t) without coolant flow in the main loop. The preliminary design of the scram system (designated off-normal scram system) which will provide the required protection is described.« less
ERIC Educational Resources Information Center
Human Engineering Inst., Cleveland, OH.
THIS MODULE OF A 25-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OPERATION AND MAINTENANCE OF SPECIFIC MODELS OF AUTOMATIC TRANSMISSIONS USED ON DIESEL POWERED VEHICLES. TOPICS ARE (1) GENERAL SPECIFICATION DATA, (2) OPTIONS FOR VARIOUS APPLICATIONS, (3) ROAD TEST INSTRUCTIONS, (4) IDENTIFICATION AND SPECIFICATION DATA, (5) ALLISON…
Phase control of the transient resonance of the automatic ball balancer
NASA Astrophysics Data System (ADS)
Michalczyk, Jerzy; Pakuła, Sebastian
2016-05-01
Hazards related to undesired increases of vibration amplitudes in transient resonance of vibroinsulated rotor systems with automatic ball balancer (ABB) are discussed in the paper. The application of the phase control method with taking into account the limited drive power is proposed for these amplitudes reduction. The high efficiency of this approach is indicated.
AUTOMOTIVE DIESEL MAINTENANCE 2. UNIT X, AUTOMATIC TRANSMISSIONS--HYDRAULIC SYSTEMS (PART II).
ERIC Educational Resources Information Center
Human Engineering Inst., Cleveland, OH.
THIS MODULE OF A 25-MODULE COURSE IS DESIGNED TO PROVIDE A SUMMARY OF MAINTENANCE PROCEDURES FOR AUTOMATIC TRANSMISSIONS USED ON DIESEL POWERED VEHICLES. TOPICS ARE (1) CHECKING THE HYDRAULIC SYSTEM, (2) SERVICING THE HYDRAULIC SYSTEM, (3) EXAMINING THE RANGE CONTROL VALVE, (4) EXAMINING THE LOCK-UP AND FLOW VALVE, (5) EXAMINING THE MAIN REGULATOR…
Automatic tracking of labeled red blood cells in microchannels.
Pinho, Diana; Lima, Rui; Pereira, Ana I; Gayubo, Fernando
2013-09-01
The current study proposes an automatic method for the segmentation and tracking of red blood cells flowing through a 100- μm glass capillary. The original images were obtained by means of a confocal system and then processed in MATLAB using the Image Processing Toolbox. The measurements obtained with the proposed automatic method were compared with the results determined by a manual tracking method. The comparison was performed by using both linear regressions and Bland-Altman analysis. The results have shown a good agreement between the two methods. Therefore, the proposed automatic method is a powerful way to provide rapid and accurate measurements for in vitro blood experiments in microchannels. Copyright © 2012 John Wiley & Sons, Ltd.
Probabilistic analysis on the failure of reactivity control for the PWR
NASA Astrophysics Data System (ADS)
Sony Tjahyani, D. T.; Deswandri; Sunaryo, G. R.
2018-02-01
The fundamental safety function of the power reactor is to control reactivity, to remove heat from the reactor, and to confine radioactive material. The safety analysis is used to ensure that each parameter is fulfilled during the design and is done by deterministic and probabilistic method. The analysis of reactivity control is important to be done because it will affect the other of fundamental safety functions. The purpose of this research is to determine the failure probability of the reactivity control and its failure contribution on a PWR design. The analysis is carried out by determining intermediate events, which cause the failure of reactivity control. Furthermore, the basic event is determined by deductive method using the fault tree analysis. The AP1000 is used as the object of research. The probability data of component failure or human error, which is used in the analysis, is collected from IAEA, Westinghouse, NRC and other published documents. The results show that there are six intermediate events, which can cause the failure of the reactivity control. These intermediate events are uncontrolled rod bank withdrawal at low power or full power, malfunction of boron dilution, misalignment of control rod withdrawal, malfunction of improper position of fuel assembly and ejection of control rod. The failure probability of reactivity control is 1.49E-03 per year. The causes of failures which are affected by human factor are boron dilution, misalignment of control rod withdrawal and malfunction of improper position for fuel assembly. Based on the assessment, it is concluded that the failure probability of reactivity control on the PWR is still within the IAEA criteria.
46 CFR 112.25-5 - Failure of power from the normal source.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Failure of power from the normal source. 112.25-5 Section 112.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas...
46 CFR 112.25-5 - Failure of power from the normal source.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Failure of power from the normal source. 112.25-5 Section 112.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas...
46 CFR 112.25-5 - Failure of power from the normal source.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Failure of power from the normal source. 112.25-5 Section 112.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas...
46 CFR 112.25-5 - Failure of power from the normal source.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Failure of power from the normal source. 112.25-5 Section 112.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas...
46 CFR 112.25-5 - Failure of power from the normal source.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Failure of power from the normal source. 112.25-5 Section 112.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas...
76 FR 66220 - Automatic Underfrequency Load Shedding and Load Shedding Plans Reliability Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-26
..., EPRI Power Systems Dynamics Tutorial, Chapter 4 at page 4-78 (2009), available at http://www.epri.com.... Power systems consist of static components (e.g., transformers and transmission lines) and dynamic... decisions on simulations, both static and dynamic, using area power system models to meet requirements in...
46 CFR 161.002-8 - Automatic fire detecting systems, general requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... detecting system shall consist of a power supply; a control unit on which are located visible and audible... control unit. Power failure alarm devices may be separately housed from the control unit and may be combined with other power failure alarm systems when specifically approved. (b) [Reserved] [21 FR 9032, Nov...
46 CFR 161.002-8 - Automatic fire detecting systems, general requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... detecting system shall consist of a power supply; a control unit on which are located visible and audible... control unit. Power failure alarm devices may be separately housed from the control unit and may be combined with other power failure alarm systems when specifically approved. (b) [Reserved] [21 FR 9032, Nov...
46 CFR 58.25-70 - Steering-gear control systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... MACHINERY AND RELATED SYSTEMS Steering Gear § 58.25-70 Steering-gear control systems. (a) Each power-driven... arranged so that one operation of the switch's lever automatically supplies power to a complete system and its associated power unit or units. This switch must be— (1) Operated by one lever; (2) Arranged so...
46 CFR 58.25-70 - Steering-gear control systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... MACHINERY AND RELATED SYSTEMS Steering Gear § 58.25-70 Steering-gear control systems. (a) Each power-driven... arranged so that one operation of the switch's lever automatically supplies power to a complete system and its associated power unit or units. This switch must be— (1) Operated by one lever; (2) Arranged so...
Temporal Dynamics of Proactive and Reactive Motor Inhibition
Liebrand, Matthias; Pein, Inga; Tzvi, Elinor; Krämer, Ulrike M.
2017-01-01
Proactive motor inhibition refers to endogenous preparatory mechanisms facilitating action inhibition, whereas reactive motor inhibition is considered to be a sudden stopping process triggered by external signals. Previous studies were inconclusive about the temporal dynamics of involved neurocognitive processes during proactive and reactive motor control. Using electroencephalography (EEG), we investigated the time-course of proactive and reactive inhibition, measuring event-related oscillations and event-related potentials (ERPs). Participants performed in a cued go/nogo paradigm with cues indicating whether the motor response might or might not have to be inhibited. Based on the dual mechanisms of control (DMC) framework by Braver, we investigated the role of attentional effects, motor preparation in the sensorimotor cortex and prefrontal cognitive control mechanisms, separating effects before and after target onset. In the cue-target interval, proactive motor inhibition was associated with increased attention, reflected in reduced visual alpha power and an increased contingent negative variation (CNV). At the same time, motor inhibition was modulated by reduced sensorimotor beta power. After target onset, proactive inhibition resulted in an increased N1, indicating allocation of attention towards relevant stimuli, increased prefrontal beta power and a modulation of sensorimotor mu activity. As in previous studies, reactive stopping of motor actions was associated with increased prefrontal beta power and increased sensorimotor beta activity. The results stress the relevance of attentional mechanisms for proactive inhibition and speak for different neurocognitive mechanisms being involved in the early preparation for and in later implementation of motor inhibition. PMID:28496405
A novel anti-theft security system for photovoltaic modules
NASA Astrophysics Data System (ADS)
Khan, Wasif Ali; Lim, Boon-Han; Lai, An-Chow; Chong, Kok-Keong
2017-04-01
Solar farms are considered as easy target for thieves because of insufficient protection measures. Existing anti-theft approaches are based on system level and are not very preventive and efficient because these can be bypassed with some technical knowledge. Additionally, it is difficult for security guards to tackle them as robbers come in a form of a gang equipped with heavy weapons. In this paper, a low power auto shut-off and non-destructive system is proposed for photovoltaic (PV) modules to achieve better level of security at module level. In proposed method, the power generation function of the PV module will be shut-off internally and cannot be re-activated by unauthorized personnel, in the case of theft. Hence, the PV module will not be functional even sold to new customers. The system comprises of a microcontroller, a low power position sensor, a controllable semiconductor switch and a wireless reactive-able system. The anti-theft system is developed to be laminated inside PV module and will be interconnected with solar cells so it becomes difficult for thieves to temper. The position of PV module is retrieved by position sensor and stored in a microcontroller as an initial reference value. Microcontroller uses this stored reference value to control power supply of PV module via power switch. The stored reference value can be altered using wireless circuitry by following authentication protocol. It makes the system non-destructive as anti-theft function can be reset again by authorized personnel, if it is recovered after theft or moved for maintenance purposes. The research component includes the design of a position sensing circuit, an auto shut-off circuit, a reactive-able wireless security protection algorithm and finally the integration of the multiple circuits.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Filippiadis, D., E-mail: dfilippiadis@yahoo.gr; Gkizas, C., E-mail: chgkizas@gmail.com; Kostantos, C., E-mail: drkarpen@yahoo.gr
PurposeTo report our experience with the use of a battery-powered drill in biopsy and radiofrequency ablation of osteoid osteoma with excess reactive new bone formation. The battery-powered drill enables obtaining the sample while drilling.Materials and MethodsDuring the last 18 months, 14 patients suffering from painful osteoid osteoma with excess reactive new bone formation underwent CT-guided biopsy and radiofrequency ablation. In order to assess and sample the nidus of the osteoid osteoma, a battery-powered drill was used. Biopsy was performed in all cases. Then, coaxially, a radiofrequency electrode was inserted and ablation was performed with osteoid osteoma protocol. Procedure time (i.e., drillingmore » including local anesthesia), amount of scans, technical and clinical success, and the results of biopsy are reported.ResultsAccess to the nidus through the excess reactive new bone formation was feasible in all cases. Median procedure time was 50.5 min. Histologic verification of osteoid osteoma was performed in all cases. Radiofrequency electrode was coaxially inserted within the nidus and ablation was successfully performed in all lesions. Median amount CT scans, performed to control correct positioning of the drill and precise electrode placement within the nidus was 11. There were no complications or material failure reported in our study.ConclusionsThe use of battery-powered drill facilitates access to the osteoid osteoma nidus in cases where excess reactive new bone formation is present. Biopsy needle can be used for channel creation during the access offering at the same time the possibility to extract bone samples.« less
Applications of the Conceptual Density Functional Theory Indices to Organic Chemistry Reactivity.
Domingo, Luis R; Ríos-Gutiérrez, Mar; Pérez, Patricia
2016-06-09
Theoretical reactivity indices based on the conceptual Density Functional Theory (DFT) have become a powerful tool for the semiquantitative study of organic reactivity. A large number of reactivity indices have been proposed in the literature. Herein, global quantities like the electronic chemical potential μ, the electrophilicity ω and the nucleophilicity N indices, and local condensed indices like the electrophilic P k + and nucleophilic P k - Parr functions, as the most relevant indices for the study of organic reactivity, are discussed.
Power flow controller with a fractionally rated back-to-back converter
Divan, Deepakraj M.; Kandula, Rajendra Prasad; Prasai, Anish
2016-03-08
A power flow controller with a fractionally rated back-to-back (BTB) converter is provided. The power flow controller provide dynamic control of both active and reactive power of a power system. The power flow controller inserts a voltage with controllable magnitude and phase between two AC sources at the same frequency; thereby effecting control of active and reactive power flows between the two AC sources. A transformer may be augmented with a fractionally rated bi-directional Back to Back (BTB) converter. The fractionally rated BTB converter comprises a transformer side converter (TSC), a direct-current (DC) link, and a line side converter (LSC). By controlling the switches of the BTB converter, the effective phase angle between the two AC source voltages may be regulated, and the amplitude of the voltage inserted by the power flow controller may be adjusted with respect to the AC source voltages.
NASA Astrophysics Data System (ADS)
Gao, F.; Song, X. H.; Zhang, Y.; Li, J. F.; Zhao, S. S.; Ma, W. Q.; Jia, Z. Y.
2017-05-01
In order to reduce the adverse effects of uncertainty on optimal dispatch in active distribution network, an optimal dispatch model based on chance-constrained programming is proposed in this paper. In this model, the active and reactive power of DG can be dispatched at the aim of reducing the operating cost. The effect of operation strategy on the cost can be reflected in the objective which contains the cost of network loss, DG curtailment, DG reactive power ancillary service, and power quality compensation. At the same time, the probabilistic constraints can reflect the operation risk degree. Then the optimal dispatch model is simplified as a series of single stage model which can avoid large variable dimension and improve the convergence speed. And the single stage model is solved using a combination of particle swarm optimization (PSO) and point estimate method (PEM). Finally, the proposed optimal dispatch model and method is verified by the IEEE33 test system.
Research on Robust Control Strategies for VSC-HVDC
NASA Astrophysics Data System (ADS)
Zhu, Kaicheng; Bao, Hai
2018-01-01
In the control system of VSC-HVDC, the phase locked loop provides phase signals to voltage vector control and trigger pulses to generate the required reference phase. The PLL is a typical second-order system. When the system is in unstable state, it will oscillate, make the trigger angle shift, produce harmonic, and make active power and reactive power coupled. Thus, considering the external disturbances introduced by the PLL in VSC-HVDC control system, the parameter perturbations of the controller and the model uncertainties, a H∞ robust controller of mixed sensitivity optimization problem is designed by using the Hinf function provided by the robust control toolbox. Then, compare it with the proportional integral controller through the MATLAB simulation experiment. By contrast, when the H∞ robust controller is added, active and reactive power of the converter station can track the change of reference values more accurately and quickly, and reduce overshoot. When the step change of active and reactive power occurs, mutual influence is reduced and better independent regulation is achieved.
Design of cylindrical pipe automatic welding control system based on STM32
NASA Astrophysics Data System (ADS)
Chen, Shuaishuai; Shen, Weicong
2018-04-01
The development of modern economy makes the demand for pipeline construction and construction rapidly increasing, and the pipeline welding has become an important link in pipeline construction. At present, there are still a large number of using of manual welding methods at home and abroad, and field pipe welding especially lacks miniature and portable automatic welding equipment. An automated welding system consists of a control system, which consisting of a lower computer control panel and a host computer operating interface, as well as automatic welding machine mechanisms and welding power systems in coordination with the control system. In this paper, a new control system of automatic pipe welding based on the control panel of the lower computer and the interface of the host computer is proposed, which has many advantages over the traditional automatic welding machine.
Post, Richard F.
2005-02-22
A motor/generator having its stationary portion, i.e., the stator, positioned concentrically within its rotatable element, i.e., the rotor, along its axis of rotation. The rotor includes a Halbach array. The stator windings are switched or commutated to provide a DC motor/generator much the same as in a conventional DC motor/generator. The voltage and power are automatically regulated by using centrifugal force to change the diameter of the rotor, and thereby vary the radial gap in between the stator and the rotating Halbach array, as a function of the angular velocity of the rotor.
Design of automatic startup and shutdown logic for a Brayton-cycle 2- to 15-kilowatt engine
NASA Technical Reports Server (NTRS)
Vrancik, J. E.; Bainbridge, R. C.
1975-01-01
The NASA Lewis Research Center is conducting a closed-Brayton-cycle power conversion system technology program in which a complete power system (engine) has been designed and demonstrated. This report discusses the design of automatic startup and shutdown logic circuits as a modification to the control system presently used in this demonstration engine. This modification was primarily intended to make starting the engine as simple and safe as possible and to allow the engine to be run unattended. In the modified configuration the engine is started by turning the control console power on and pushing the start button after preheating the gas loop. No other operator action is required to effect a complete startup. Shutdown, if one is required, is also effected by a simple stop button. The automatic startup and shutdown of the engine have been successfully and purposefully demonstrated more than 50 times at the Lewis Research Center during 10,000 hours of unattended operation. The net effect of this modification is an engine that can be safely started and stopped by relatively untrained personnel. The approach lends itself directly to remote unattended operation.
Jack Lewis; Rand Eads
1998-01-01
Abstract - For estimating suspended sediment concentration (SSC) in rivers, turbidity is potentially a much better predictor than water discharge. Since about 1990, it has been feasible to automatically collect high frequency turbidity data at remote sites using battery-powered turbidity probes that are properly mounted in the river or stream. With sensors calibrated...
Use of Automatic Interaction Detector in Monitoring Faculty Salaries. AIR 1983 Annual Forum Paper.
ERIC Educational Resources Information Center
Cohen, Margaret E.
A university's use of the Automatic Interaction Detector (AID) to monitor faculty salary data is described. The first step consists of examining a tree diagram and summary table produced by AID. The tree is used to identify the characteristics of faculty at different salary levels. The table is used to determine the explanatory power of the…
NASA Technical Reports Server (NTRS)
Freeman, Frederick
1995-01-01
A biocybernetic system for use in adaptive automation was evaluated using EEG indices based on the beta, alpha, and theta bandwidths. Subjects performed a compensatory tracking task while their EEG was recorded and one of three engagement indices was derived: beta/(alpha + theta), beta/alpha, or 1/alpha. The task was switched between manual and automatic modes as a function of the subjects' level of engagement and whether they were under a positive or negative feedback condition. It was hypothesized that negative feedback would produce more switches between manual and automatic modes, and that the beta/(alpha + theta) index would produce the strongest effect. The results confirmed these hypotheses. There were no systematic changes in these effects over three 16-minute trials. Tracking performance was found to be better under negative feedback. An analysis of the different EEG bands under positive and negative feedback in manual and automatic modes found more beta power in the positive feedback/manual condition and less in the positive feedback/automatic condition. The opposite effect was observed for alpha and theta power. The implications of biocybernetic systems for adaptive automation are discussed.
Automatic recloser circuit breaker integrated with GSM technology for power system notification
NASA Astrophysics Data System (ADS)
Lada, M. Y.; Khiar, M. S. A.; Ghani, S. A.; Nawawi, M. R. M.; Rahim, N. H.; Sinar, L. O. M.
2015-05-01
Lightning is one type of transient faults that usually cause the circuit breaker in the distribution board trip due to overload current detection. The instant tripping condition in the circuit breakers clears the fault in the system. Unfortunately most circuit breakers system is manually operated. The power line will be effectively re-energized after the clearing fault process is finished. Auto-reclose circuit is used on the transmission line to carry out the duty of supplying quality electrical power to customers. In this project, an automatic reclose circuit breaker for low voltage usage is designed. The product description is the Auto Reclose Circuit Breaker (ARCB) will trip if the current sensor detects high current which exceeds the rated current for the miniature circuit breaker (MCB) used. Then the fault condition will be cleared automatically and return the power line to normal condition. The Global System for Mobile Communication (GSM) system will send SMS to the person in charge if the tripping occurs. If the over current occurs in three times, the system will fully trip (open circuit) and at the same time will send an SMS to the person in charge. In this project a 1 A is set as the rated current and any current exceeding a 1 A will cause the system to trip or interrupted. This system also provides an additional notification for user such as the emergency light and warning system.
Intelligent system for a remote diagnosis of a photovoltaic solar power plant
NASA Astrophysics Data System (ADS)
Sanz-Bobi, M. A.; Muñoz San Roque, A.; de Marcos, A.; Bada, M.
2012-05-01
Usually small and mid-sized photovoltaic solar power plants are located in rural areas and typically they operate unattended. Some technicians are in charge of the supervision of these plants and, if an alarm is automatically issued, they try to investigate the problem and correct it. Sometimes these anomalies are detected some hours or days after they begin. Also the analysis of the causes once the anomaly is detected can take some additional time. All these factors motivated the development of a methodology able to perform continuous and automatic monitoring of the basic parameters of a photovoltaic solar power plant in order to detect anomalies as soon as possible, to diagnose their causes, and to immediately inform the personnel in charge of the plant. The methodology proposed starts from the study of the most significant failure modes of a photovoltaic plant through a FMEA and using this information, its typical performance is characterized by the creation of its normal behaviour models. They are used to detect the presence of a failure in an incipient or current form. Once an anomaly is detected, an automatic and intelligent diagnosis process is started in order to investigate the possible causes. The paper will describe the main features of a software tool able to detect anomalies and to diagnose them in a photovoltaic solar power plant.
Towards Time Automata and Multi-Agent Systems
NASA Technical Reports Server (NTRS)
Hutzler, G.; Klaudel, H.; Wang, D. Y.
2004-01-01
The design of reactive systems must comply with logical correctness (the system does what it is supposed to do) and timeliness (the system has to satisfy a set of temporal constraints) criteria. In this paper, we propose a global approach for the design of adaptive reactive systems, i.e., systems that dynamically adapt their architecture depending on the context. We use the timed automata formalism for the design of the agents' behavior. This allows evaluating beforehand the properties of the system (regarding logical correctness and timeliness), thanks to model-checking and simulation techniques. This model is enhanced with tools that we developed for the automatic generation of code, allowing to produce very quickly a running multi-agent prototype satisfying the properties of the model.
Toward Agent Programs with Circuit Semantics
NASA Technical Reports Server (NTRS)
Nilsson, Nils J.
1992-01-01
New ideas are presented for computing and organizing actions for autonomous agents in dynamic environments-environments in which the agent's current situation cannot always be accurately discerned and in which the effects of actions cannot always be reliably predicted. The notion of 'circuit semantics' for programs based on 'teleo-reactive trees' is introduced. Program execution builds a combinational circuit which receives sensory inputs and controls actions. These formalisms embody a high degree of inherent conditionality and thus yield programs that are suitably reactive to their environments. At the same time, the actions computed by the programs are guided by the overall goals of the agent. The paper also speculates about how programs using these ideas could be automatically generated by artificial intelligence planning systems and adapted by learning methods.
46 CFR 161.002-12 - Manual fire alarm systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... (a) General. A manual fire alarm system shall consist of a power supply, a control unit on which are... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The power supply shall be as specified for automatic fire detecting system by § 161.002-9. (d) Manual fire...
46 CFR 161.002-12 - Manual fire alarm systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
.... (a) General. A manual fire alarm system shall consist of a power supply, a control unit on which are... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The power supply shall be as specified for automatic fire detecting system by § 161.002-9. (d) Manual fire...
Ayub, Qaisar; Ngadi, Asri; Rashid, Sulma; Habib, Hafiz Adnan
2018-01-01
Delay Tolerant Network (DTN) multi-copy routing protocols are privileged to create and transmit multiple copies of each message that causes congestion and some messages are dropped. This process is known as reactive drop because messages were dropped re-actively to overcome buffer overflows. The existing reactive buffer management policies apply a single metric to drop source, relay and destine messages. Hereby, selection to drop a message is dubious because each message as source, relay or destine may have consumed dissimilar magnitude of network resources. Similarly, DTN has included time to live (ttl) parameter which defines lifetime of message. Hence, when ttl expires then message is automatically destroyed from relay nodes. However, time-to-live (ttl) is not applicable on messages reached at their destinations. Moreover, nodes keep replicating messages till ttl expires even-though large number of messages has already been dispersed. In this paper, we have proposed Priority Queue Based Reactive Buffer Management Policy (PQB-R) for DTN under City Based Environments. The PQB-R classifies buffered messages into source, relay and destine queues. Moreover, separate drop metric has been applied on individual queue. The experiment results prove that proposed PQB-R has reduced number of messages transmissions, message drop and increases delivery ratio.
Ngadi, Asri; Rashid, Sulma; Habib, Hafiz Adnan
2018-01-01
Delay Tolerant Network (DTN) multi-copy routing protocols are privileged to create and transmit multiple copies of each message that causes congestion and some messages are dropped. This process is known as reactive drop because messages were dropped re-actively to overcome buffer overflows. The existing reactive buffer management policies apply a single metric to drop source, relay and destine messages. Hereby, selection to drop a message is dubious because each message as source, relay or destine may have consumed dissimilar magnitude of network resources. Similarly, DTN has included time to live (ttl) parameter which defines lifetime of message. Hence, when ttl expires then message is automatically destroyed from relay nodes. However, time-to-live (ttl) is not applicable on messages reached at their destinations. Moreover, nodes keep replicating messages till ttl expires even-though large number of messages has already been dispersed. In this paper, we have proposed Priority Queue Based Reactive Buffer Management Policy (PQB-R) for DTN under City Based Environments. The PQB-R classifies buffered messages into source, relay and destine queues. Moreover, separate drop metric has been applied on individual queue. The experiment results prove that proposed PQB-R has reduced number of messages transmissions, message drop and increases delivery ratio. PMID:29438438
Multiple sclerosis lesion segmentation using an automatic multimodal graph cuts.
García-Lorenzo, Daniel; Lecoeur, Jeremy; Arnold, Douglas L; Collins, D Louis; Barillot, Christian
2009-01-01
Graph Cuts have been shown as a powerful interactive segmentation technique in several medical domains. We propose to automate the Graph Cuts in order to automatically segment Multiple Sclerosis (MS) lesions in MRI. We replace the manual interaction with a robust EM-based approach in order to discriminate between MS lesions and the Normal Appearing Brain Tissues (NABT). Evaluation is performed in synthetic and real images showing good agreement between the automatic segmentation and the target segmentation. We compare our algorithm with the state of the art techniques and with several manual segmentations. An advantage of our algorithm over previously published ones is the possibility to semi-automatically improve the segmentation due to the Graph Cuts interactive feature.
A Three-Stage Enhanced Reactive Power and Voltage Optimization Method for High Penetration of Solar
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ke, Xinda; Huang, Renke; Vallem, Mallikarjuna R.
This paper presents a three-stage enhanced volt/var optimization method to stabilize voltage fluctuations in transmission networks by optimizing the usage of reactive power control devices. In contrast with existing volt/var optimization algorithms, the proposed method optimizes the voltage profiles of the system, while keeping the voltage and real power output of the generators as close to the original scheduling values as possible. This allows the method to accommodate realistic power system operation and market scenarios, in which the original generation dispatch schedule will not be affected. The proposed method was tested and validated on a modified IEEE 118-bus system withmore » photovoltaic data.« less
NASA Astrophysics Data System (ADS)
Abdellaoui, Amr
This research project presents a complete modelling process of the effects of GIC on Hydro-Quebec power system network for system planning studies. The advantage of the presented method is that it enables planning engineers to simulate the effects of geomagnetic disturbances on the Hydro-Quebec System under different conditions and contingencies within reasonable calculation time frame. This modelling method of GIC in electric power systems has been applied to the Hydro-Quebec System. An equivalent HQ DC model has been achieved. A numerical calculation method of DC sources from a non-uniform geoelectric field has been developed and implemented on HQ DC model. Harmonics and increased reactive power losses of saturated transformers have been defined as a function of GIC through a binary search algorithm using a chosen HQ magnetization curve. The evolution in time of each transformer saturation according to its effective GIC has been evaluated using analytical formulas. The reactive power losses of saturated transformers have been modeled in PSS/E[1] HQ network as constant reactive current loads assigned to the corresponding transformer buses. Finally, time domain simulations have been performed with PSS/E taking into account transformer saturation times. This has been achieved by integrating HQ DC model results and analytical calculations results of transformer saturation times into an EMTP load model. An interface has been used to link EMTP load model to HQ PSS/E network. Different aspects of GIC effects on the Hydro-Quebec system have been studied, including the influence of uniform and non-uniform geoelectric fields, the comparison of reactive power losses of the 735kV HQ system with those of Montreal network, the risks to voltage levels and the importance of reactive power dynamic reserve. This dissertation presents a new GIC modelling approach for power systems for planning and operations purposes. This methodology could be further enhanced, particularly, the aspect regarding the transformer saturation times. Hence more research remains to be pursued in this area.
Integrating hidden Markov model and PRAAT: a toolbox for robust automatic speech transcription
NASA Astrophysics Data System (ADS)
Kabir, A.; Barker, J.; Giurgiu, M.
2010-09-01
An automatic time-aligned phone transcription toolbox of English speech corpora has been developed. Especially the toolbox would be very useful to generate robust automatic transcription and able to produce phone level transcription using speaker independent models as well as speaker dependent models without manual intervention. The system is based on standard Hidden Markov Models (HMM) approach and it was successfully experimented over a large audiovisual speech corpus namely GRID corpus. One of the most powerful features of the toolbox is the increased flexibility in speech processing where the speech community would be able to import the automatic transcription generated by HMM Toolkit (HTK) into a popular transcription software, PRAAT, and vice-versa. The toolbox has been evaluated through statistical analysis on GRID data which shows that automatic transcription deviates by an average of 20 ms with respect to manual transcription.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elizondo, Marcelo A.; Samaan, Nader A.; Makarov, Yuri V.
Voltage and reactive power system control is generally performed following usual patterns of loads, based on off-line studies for daily and seasonal operations. This practice is currently challenged by the inclusion of distributed renewable generation, such as solar. There has been focus on resolving this problem at the distribution level; however, the transmission and sub-transmission levels have received less attention. This paper provides a literature review of proposed methods and solution approaches to coordinate and optimize voltage control and reactive power management, with an emphasis on applications at transmission and sub-transmission level. The conclusion drawn from the survey is thatmore » additional research is needed in the areas of optimizing switch shunt actions and coordinating all available resources to deal with uncertain patterns from increasing distributed renewable generation in the operational time frame. These topics are not deeply explored in the literature.« less
Modified artificial bee colony algorithm for reactive power optimization
NASA Astrophysics Data System (ADS)
Sulaiman, Noorazliza; Mohamad-Saleh, Junita; Abro, Abdul Ghani
2015-05-01
Bio-inspired algorithms (BIAs) implemented to solve various optimization problems have shown promising results which are very important in this severely complex real-world. Artificial Bee Colony (ABC) algorithm, a kind of BIAs has demonstrated tremendous results as compared to other optimization algorithms. This paper presents a new modified ABC algorithm referred to as JA-ABC3 with the aim to enhance convergence speed and avoid premature convergence. The proposed algorithm has been simulated on ten commonly used benchmarks functions. Its performance has also been compared with other existing ABC variants. To justify its robust applicability, the proposed algorithm has been tested to solve Reactive Power Optimization problem. The results have shown that the proposed algorithm has superior performance to other existing ABC variants e.g. GABC, BABC1, BABC2, BsfABC dan IABC in terms of convergence speed. Furthermore, the proposed algorithm has also demonstrated excellence performance in solving Reactive Power Optimization problem.
He, Xiu; Yan, Guo-Zheng; Wang, Fu-Min
2008-01-01
A wireless energy transmission system for the MEMS system inside alimentary tracts is reported here in the paper. It consists of an automatic frequency tracking circuit of phase lock loop and phase shift PWM control circuit. Experimental results show that the energy transmission system is capable of automatic frequency-tracking and transmission power-adjusting and has stable received energy.
Space fabrication demonstration system, technical volume
NASA Technical Reports Server (NTRS)
1979-01-01
The automatic beam builder ABB was developed, fabricated, and demonstrated within the established contract cost and schedule constraints. The ABB demonstrated the feasibility of: producing lightweight beams automatically within the required rate of 1 to 5 ft of completed beam per minute and producing structurally sound beams with axial design load of 5538 N based on the Grumman photovoltaic satellite solar power system design reference structure.
EBR-II high-ramp transients under computer control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forrester, R.J.; Larson, H.A.; Christensen, L.J.
1983-01-01
During reactor run 122, EBR-II was subjected to 13 computer-controlled overpower transients at ramps of 4 MWt/s to qualify the facility and fuel for transient testing of LMFBR oxide fuels as part of the EBR-II operational-reliability-testing (ORT) program. A computer-controlled automatic control-rod drive system (ACRDS), designed by EBR-II personnel, permitted automatic control on demand power during the transients.
NASA Astrophysics Data System (ADS)
Shinohara, Katsuji; Shinhatsubo, Kurato; Iimori, Kenichi; Yamamoto, Kichiro; Saruban, Takamichi; Yamaemori, Takahiro
In recent year, consciousness of environmental problems is enhancing, and the price of the electric power purchased by an electric power company is established expensive for the power plant utilizing the natural energy. So, the introduction of the wind power generation is promoted in Japan. Generally, squirrel-cage induction machines are widely used as a generator in wind power generation system because of its small size, lightweight and low-cost. However, the induction machines do not have a source of excitation. Thus, it causes the inrush currents and the instantaneous voltage drop when the generator is directly connected to a power grid. To reduce the inrush currents, an AC power regulator is used. Wind power generations are frequently connected to and disconnected from the power grid. However, when the inrush currents are reduced, harmonic currents are caused by phase control of the AC power regulator. And the phase control of AC power regulator cannot control the power factor. Therefore, we propose the use of the AC power regulator to compensate for the harmonic currents and reactive power in the wind power generation system, and demonstrate the validity of its system by simulated and experimental results.
Integration of Variable Speed Pumped Hydro Storage in Automatic Generation Control Systems
NASA Astrophysics Data System (ADS)
Fulgêncio, N.; Moreira, C.; Silva, B.
2017-04-01
Pumped storage power (PSP) plants are expected to be an important player in modern electrical power systems when dealing with increasing shares of new renewable energies (NRE) such as solar or wind power. The massive penetration of NRE and consequent replacement of conventional synchronous units will significantly affect the controllability of the system. In order to evaluate the capability of variable speed PSP plants participation in the frequency restoration reserve (FRR) provision, taking into account the expected performance in terms of improved ramp response capability, a comparison with conventional hydro units is presented. In order to address this issue, a three area test network was considered, as well as the corresponding automatic generation control (AGC) systems, being responsible for re-dispatching the generation units to re-establish power interchange between areas as well as the system nominal frequency. The main issue under analysis in this paper is related to the benefits of the fast response of variable speed PSP with respect to its capability of providing fast power balancing in a control area.
Power Plant Model Validation Tool
DOE Office of Scientific and Technical Information (OSTI.GOV)
The PPMV is used to validate generator model using disturbance recordings. The PPMV tool contains a collection of power plant models and model validation studies, as well as disturbance recordings from a number of historic grid events. The user can import data from a new disturbance into the database, which converts PMU and SCADA data into GE PSLF format, and then run the tool to validate (or invalidate) the model for a specific power plant against its actual performance. The PNNL PPMV tool enables the automation of the process of power plant model validation using disturbance recordings. The tool usesmore » PMU and SCADA measurements as input information. The tool automatically adjusts all required EPCL scripts and interacts with GE PSLF in the batch mode. The main tool features includes: The tool interacts with GE PSLF; The tool uses GE PSLF Play-In Function for generator model validation; Database of projects (model validation studies); Database of the historic events; Database of the power plant; The tool has advanced visualization capabilities; and The tool automatically generates reports« less
NASA Technical Reports Server (NTRS)
Vranish, John M.
1993-01-01
Roller locking brake is normally braking rotary mechanism allowing free rotation when electromagnet in mechanism energized. Well suited to robots and other machinery which automatic braking upon removal of electrical power required. More compact and reliable. Requires little electrical power to maintain free rotation and exhibits minimal buildup of heat.
Module-oriented modeling of reactive transport with HYTEC
NASA Astrophysics Data System (ADS)
van der Lee, Jan; De Windt, Laurent; Lagneau, Vincent; Goblet, Patrick
2003-04-01
The paper introduces HYTEC, a coupled reactive transport code currently used for groundwater pollution studies, safety assessment of nuclear waste disposals, geochemical studies and interpretation of laboratory column experiments. Based on a known permeability field, HYTEC evaluates the groundwater flow paths, and simulates the migration of mobile matter (ions, organics, colloids) subject to geochemical reactions. The code forms part of a module-oriented structure which facilitates maintenance and improves coding flexibility. In particular, using the geochemical module CHESS as a common denominator for several reactive transport models significantly facilitates the development of new geochemical features which become automatically available to all models. A first example shows how the model can be used to assess migration of uranium from a sub-surface source under the effect of an oxidation front. The model also accounts for alteration of hydrodynamic parameters (local porosity, permeability) due to precipitation and dissolution of mineral phases, which potentially modifies the migration properties in general. The second example illustrates this feature.
EVA Metro Sedan electric-propulsion system: test and evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reimers, E.
1979-09-01
The procedure and results of the performance evaluation of the EVA Metro Sedan (car No. 1) variable speed dc chopper motor drive and its three speed automatic transmission are presented. The propulsion system for a battery powered vehicle manufactured by Electric Vehicle Associates, Valley View, Ohio, was removed from the vehicle, mounted on the programmable electric dynamometer test facility and evaluated with the aid of a hp 3052A Data Acquisition System. Performance data for the automatic transmission, the solid state dc motor speed controller, and the dc motor in the continuous and pulsating dc power mode, as derived on themore » dynamometer test facility, as well as the entire propulsion system are given. This concept and the system's components were evaluated in terms of commercial applicability, maintainability, and energy utility to establish a design base for the further development of this system or similar propulsion drives. The propulsion system of the EVA Metro Sedan is powered by sixteen 6-volt traction batteries, Type EV 106 (Exide Battery Mfg. Co.). A thyristor controlled cable form Pulsomatic Mark 10 controller, actuated by a foot throttle, controls the voltage applied to a dc series field motor, rated at 10 hp at 3800 rpm (Baldor Electric Co.). Gear speed reduction to the wheel is accomplished by the original equipment three speed automatic transmission with torque converter (Renault 12 Sedan). The brake consists of a power-assisted, hydraulic braking system with front wheel disk and rear drum. An ability to recuperate electric energy with subsequent storage in the battery power supply is not provided.« less
Racsmány, Mihály; Szőllősi, Ágnes; Bencze, Dorottya
2018-01-01
The "testing effect" refers to the striking phenomenon that repeated retrieval practice is one of the most effective learning strategies, and certainly more advantageous for long-term learning, than additional restudying of the same information. How retrieval can boost the retention of memories is still without unanimous explanation. In 3 experiments, focusing on the reaction time (RT) of retrieval, we showed that RT of retrieval during retrieval practice followed a power function speed up that typically characterizes automaticity and skill learning. More important, it was found that the measure of goodness of fit to this power function was associated with long-term recall success. Here we suggest that the automatization of retrieval is an explanatory component of the testing effect. As a consequence, retrieval-based learning has the properties characteristic of skill learning: diminishing involvement of attentional processes, faster processing, resistance to interference effects, and lower forgetting rate. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Proactive Fault Tolerance for HPC with Xen Virtualization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nagarajan, Arun Babu; Mueller, Frank; Engelmann, Christian
2007-01-01
with thousands of processors. At such large counts of compute nodes, faults are becoming common place. Current techniques to tolerate faults focus on reactive schemes to recover from faults and generally rely on a checkpoint/restart mechanism. Yet, in today's systems, node failures can often be anticipated by detecting a deteriorating health status. Instead of a reactive scheme for fault tolerance (FT), we are promoting a proactive one where processes automatically migrate from unhealthy nodes to healthy ones. Our approach relies on operating system virtualization techniques exemplied by but not limited to Xen. This paper contributes an automatic and transparent mechanismmore » for proactive FT for arbitrary MPI applications. It leverages virtualization techniques combined with health monitoring and load-based migration. We exploit Xen's live migration mechanism for a guest operating system (OS) to migrate an MPI task from a health-deteriorating node to a healthy one without stopping the MPI task during most of the migration. Our proactive FT daemon orchestrates the tasks of health monitoring, load determination and initiation of guest OS migration. Experimental results demonstrate that live migration hides migration costs and limits the overhead to only a few seconds making it an attractive approach to realize FT in HPC systems. Overall, our enhancements make proactive FT a valuable asset for long-running MPI application that is complementary to reactive FT using full checkpoint/ restart schemes since checkpoint frequencies can be reduced as fewer unanticipated failures are encountered. In the context of OS virtualization, we believe that this is the rst comprehensive study of proactive fault tolerance where live migration is actually triggered by health monitoring.« less
Development and evaluation of a self-regulating alternating pressure air cushion.
Nakagami, Gojiro; Sanada, Hiromi; Sugama, Junko
2015-03-01
To investigate the effect of alternating air cells of a newly developed dynamic cushion on interface pressure and tissue oxygenation levels. This cross-over experimental study included 19 healthy volunteers. The dynamic cushion used has an automatic self-regulating alternating pressure air-cell system with 35 small and four large air cells for maintaining posture while seated. This cushion also has 17 bottoming-out detectors that automatically inflate the air cells to release a high interface pressure. To assess the effect of this alternating system, participants sat on the new cushion with an alternating system or static system for 30 min and then performed push-ups. The interface pressure was monitored by pressure-sensitive and conductive ink film sensors and tissue oxygenation levels were monitored by near-infrared spectroscopy. A reactive hyperaemia indicator was calculated using tissue oxygenation levels as an outcome measure. The peak interface pressure was not significantly different between the groups. The reactive hyperaemia indicator was significantly higher in the static group than in the alternating group. An alternating system has beneficial effects on blood oxygenation levels without increasing interface pressure. Therefore, our new cushion is promising for preventing pressure ulcers with patients with limited ability to perform push-ups. Implications for Rehabilitation A dynamic cushion was developed, which consists of a uniquely-designed air-cell layout, detectors for bottoming out, and an alternating system with multiple air-cell lines. The alternating system did not increase interface pressure and it significantly reduced reactive hyperaemia after 30 min of sitting in healthy volunteers. This cushion is a new option for individuals who require stable posture but have limitations in performing scheduled push-ups for prevention of pressure ulcers.
Intelligent Distribution Voltage Control with Distributed Generation =
NASA Astrophysics Data System (ADS)
Castro Mendieta, Jose
In this thesis, three methods for the optimal participation of the reactive power of distributed generations (DGs) in unbalanced distributed network have been proposed, developed, and tested. These new methods were developed with the objectives of maintain voltage within permissible limits and reduce losses. The first method proposes an optimal participation of reactive power of all devices available in the network. The propose approach is validated by comparing the results with other methods reported in the literature. The proposed method was implemented using Simulink of Matlab and OpenDSS. Optimization techniques and the presentation of results are from Matlab. The co-simulation of Electric Power Research Institute's (EPRI) OpenDSS program solves a three-phase optimal power flow problem in the unbalanced IEEE 13 and 34-node test feeders. The results from this work showed a better loss reduction compared to the Coordinated Voltage Control (CVC) method. The second method aims to minimize the voltage variation on the pilot bus on distribution network using DGs. It uses Pareto and Fuzzy-PID logic to reduce the voltage variation. Results indicate that the proposed method reduces the voltage variation more than the other methods. Simulink of Matlab and OpenDSS is used in the development of the proposed approach. The performance of the method is evaluated on IEEE 13-node test feeder with one and three DGs. Variables and unbalanced loads are used, based on real consumption data, over a time window of 48 hours. The third method aims to minimize the reactive losses using DGs on distribution networks. This method analyzes the problem using the IEEE 13-node test feeder with three different loads and the IEEE 123-node test feeder with four DGs. The DGs can be fixed or variables. Results indicate that integration of DGs to optimize the reactive power of the network helps to maintain the voltage within the allowed limits and to reduce the reactive power losses. The thesis is presented in the form of the three articles. The first article is published in the journal Electrical Power and Energy System, the second is published in the international journal Energies and the third was submitted to the journal Electrical Power and Energy System. Two other articles have been published in conferences with reviewing committee. This work is based on six chapters, which are detailed in the various sections of the thesis.
Cascaded H-bridge multilevel inverter for renewable energy generation
NASA Astrophysics Data System (ADS)
Pandey, Ravikant; Nath Tripathi, Ravi; Hanamoto, Tsuyoshi
2016-04-01
In this paper cascaded H-bridge multilevel inverter (CHBMLI) has been investigated for the application of renewable energy generation. Energy sources like solar, wind, hydro, biomass or combination of these can be manipulated to obtain alternative sources for renewable energy generation. These renewable energy sources have different electrical characteristics like DC or AC level so it is challenging to use generated power by connecting to grid or load directly. The renewable energy source require specific power electronics converter as an interface for conditioning generated power .The multilevel inverter can be utilized for renewable energy sources in two different modes, the power generation mode (stand-alone mode), and compensator mode (statcom). The performance of the multilevel inverter has been compared with two level inverter. In power generation mode CHBMLI supplies the active and reactive power required by the different loads. For operation in compensator mode the indirect current control based on synchronous reference frame theory (SRFT) ensures the grid operating in unity power factor and compensate harmonics and reactive power.
Photovoltaic Hosting Capacity of Feeders with Reactive Power Control and Tap Changers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ceylan, Oğuzhan; Paudyal, Sumit; Bhattarai, Bishnu P.
This paper proposes an algorithm to determine photovoltaic (PV) hosting capacity of power distribution networks as a function of number of PV injection nodes, reactive power support from the PVs, and the sub-station load tap changers (LTCs). In the proposed method, several minute by minute simulations are run based on randomly chosen PV injection nodes, daily PV output profiles, and daily load profiles from a pool of high-resolution realistic data set. The simulation setup is built using OpenDSS and MATLAB. The performance of the proposed method is investigated in the IEEE 123-node distribution feeder for multiple scenarios. The case studiesmore » are performed particularly for one, two, five and ten PV injection nodes, and looking at the maximum voltage deviations. Case studies show that the PV hosting capacity of the 123-node feeder greatly differs with the number of PV injection nodes. We have also observed that the PV hosting capacity increases with reactive power support and higher tap position of sub-station LTC.« less
Automatic Methods and Tools for the Verification of Real Time Systems
1997-07-31
real - time systems . This was accomplished by extending techniques, based on automata theory and temporal logic, that have been successful for the verification of time-independent reactive systems. As system specification lanmaage for embedded real - time systems , we introduced hybrid automata, which equip traditional discrete automata with real-numbered clock variables and continuous environment variables. As requirements specification languages, we introduced temporal logics with clock variables for expressing timing constraints.
46 CFR 112.30-10 - Restoration of normal source potential.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Section 112.30-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-10 Restoration of normal source potential. When the potential...
46 CFR 112.30-3 - Normal source for emergency loads.
Code of Federal Regulations, 2012 CFR
2012-10-01
....30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-3 Normal source for emergency loads. (a) The normal source...
46 CFR 112.30-5 - Transfer of emergency loads.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-5 Transfer of emergency loads. If there is a reduction of potential of the...
46 CFR 112.30-3 - Normal source for emergency loads.
Code of Federal Regulations, 2010 CFR
2010-10-01
....30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-3 Normal source for emergency loads. (a) The normal source...
46 CFR 112.30-3 - Normal source for emergency loads.
Code of Federal Regulations, 2013 CFR
2013-10-01
....30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-3 Normal source for emergency loads. (a) The normal source...
46 CFR 112.30-5 - Transfer of emergency loads.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-5 Transfer of emergency loads. If there is a reduction of potential of the...
46 CFR 112.30-10 - Restoration of normal source potential.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Section 112.30-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-10 Restoration of normal source potential. When the potential...
46 CFR 112.30-10 - Restoration of normal source potential.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 112.30-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-10 Restoration of normal source potential. When the potential...
46 CFR 112.30-10 - Restoration of normal source potential.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Section 112.30-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-10 Restoration of normal source potential. When the potential...
46 CFR 112.30-5 - Transfer of emergency loads.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-5 Transfer of emergency loads. If there is a reduction of potential of the...
46 CFR 112.30-5 - Transfer of emergency loads.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-5 Transfer of emergency loads. If there is a reduction of potential of the...
46 CFR 112.30-3 - Normal source for emergency loads.
Code of Federal Regulations, 2014 CFR
2014-10-01
....30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-3 Normal source for emergency loads. (a) The normal source...
46 CFR 112.30-3 - Normal source for emergency loads.
Code of Federal Regulations, 2011 CFR
2011-10-01
....30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-3 Normal source for emergency loads. (a) The normal source...
46 CFR 112.30-10 - Restoration of normal source potential.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Section 112.30-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-10 Restoration of normal source potential. When the potential...
46 CFR 112.30-5 - Transfer of emergency loads.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-5 Transfer of emergency loads. If there is a reduction of potential of the...
Grid Modeling Tools | Grid Modernization | NREL
integrates primary frequency response (turbine governor control) with secondary frequency response (automatic generation control). It simulates the power system dynamic response in full time spectrum with variable time control model places special emphasis on electric power systems with high penetrations of renewable
Network-Cognizant Voltage Droop Control for Distribution Grids
Baker, Kyri; Bernstein, Andrey; Dall'Anese, Emiliano; ...
2017-08-07
Our paper examines distribution systems with a high integration of distributed energy resources (DERs) and addresses the design of local control methods for real-time voltage regulation. Particularly, the paper focuses on proportional control strategies where the active and reactive output-powers of DERs are adjusted in response to (and proportionally to) local changes in voltage levels. The design of the voltage-active power and voltage-reactive power characteristics leverages suitable linear approximation of the AC power-flow equations and is network-cognizant; that is, the coefficients of the controllers embed information on the location of the DERs and forecasted non-controllable loads/injections and, consequently, on themore » effect of DER power adjustments on the overall voltage profile. We pursued a robust approach to cope with uncertainty in the forecasted non-controllable loads/power injections. Stability of the proposed local controllers is analytically assessed and numerically corroborated.« less
Network-Cognizant Voltage Droop Control for Distribution Grids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, Kyri; Bernstein, Andrey; Dall'Anese, Emiliano
Our paper examines distribution systems with a high integration of distributed energy resources (DERs) and addresses the design of local control methods for real-time voltage regulation. Particularly, the paper focuses on proportional control strategies where the active and reactive output-powers of DERs are adjusted in response to (and proportionally to) local changes in voltage levels. The design of the voltage-active power and voltage-reactive power characteristics leverages suitable linear approximation of the AC power-flow equations and is network-cognizant; that is, the coefficients of the controllers embed information on the location of the DERs and forecasted non-controllable loads/injections and, consequently, on themore » effect of DER power adjustments on the overall voltage profile. We pursued a robust approach to cope with uncertainty in the forecasted non-controllable loads/power injections. Stability of the proposed local controllers is analytically assessed and numerically corroborated.« less
NASA Astrophysics Data System (ADS)
Clamens, Olivier; Lecerf, Johann; Hudelot, Jean-Pascal; Duc, Bertrand; Cadiou, Thierry; Blaise, Patrick; Biard, Bruno
2018-01-01
CABRI is an experimental pulse reactor, funded by the French Nuclear Safety and Radioprotection Institute (IRSN) and operated by CEA at the Cadarache research center. It is designed to study fuel behavior under RIA conditions. In order to produce the power transients, reactivity is injected by depressurization of a neutron absorber (3He) situated in transient rods inside the reactor core. The shapes of power transients depend on the total amount of reactivity injected and on the injection speed. The injected reactivity can be calculated by conversion of the 3He gas density into units of reactivity. So, it is of upmost importance to properly master gas density evolution in transient rods during a power transient. The 3He depressurization was studied by CFD calculations and completed with measurements using pressure transducers. The CFD calculations show that the density evolution is slower than the pressure drop. Surrogate models were built based on CFD calculations and validated against preliminary tests in the CABRI transient system. Studies also show that it is harder to predict the depressurization during the power transients because of neutron/3He capture reactions that induce a gas heating. This phenomenon can be studied by a multiphysics approach based on reaction rate calculation thanks to Monte Carlo code and study the resulting heating effect with the validated CFD simulation.
NASA Astrophysics Data System (ADS)
Dobra, R.; Pasculescu, D.; Risteiu, M.; Buica, G.; Jevremović, V.
2017-06-01
This paper describe some possibilities to minimize voltages switching-off risks from the mining power networks, in case of insulated resistance faults by using a predictive diagnose method. The cables from the neutral insulated power networks (underground mining) are designed to provide a flexible electrical connection between portable or mobile equipment and a point of supply, including main feeder cable for continuous miners, pump cable, and power supply cable. An electronic protection for insulated resistance of mining power cables can be made using this predictive strategy. The main role of electronic relays for insulation resistance degradation of the electrical power cables, from neutral insulated power networks, is to provide a permanent measurement of the insulated resistance between phases and ground, in order to switch-off voltage when the resistance value is below a standard value. The automat system of protection is able to signalize the failure and the human operator will be early informed about the switch-off power and will have time to take proper measures to fix the failure. This logic for fast and automat switch-off voltage without aprioristic announcement is suitable for the electrical installations, realizing so a protection against fires and explosion. It is presented an algorithm and an anticipative relay for insulated resistance control from three-phase low voltage installations with insulated neutral connection.
Automatic Regionalization Algorithm for Distributed State Estimation in Power Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Dexin; Yang, Liuqing; Florita, Anthony
The deregulation of the power system and the incorporation of generation from renewable energy sources recessitates faster state estimation in the smart grid. Distributed state estimation (DSE) has become a promising and scalable solution to this urgent demand. In this paper, we investigate the regionalization algorithms for the power system, a necessary step before distributed state estimation can be performed. To the best of the authors' knowledge, this is the first investigation on automatic regionalization (AR). We propose three spectral clustering based AR algorithms. Simulations show that our proposed algorithms outperform the two investigated manual regionalization cases. With the helpmore » of AR algorithms, we also show how the number of regions impacts the accuracy and convergence speed of the DSE and conclude that the number of regions needs to be chosen carefully to improve the convergence speed of DSEs.« less
Automatic Regionalization Algorithm for Distributed State Estimation in Power Systems: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Dexin; Yang, Liuqing; Florita, Anthony
The deregulation of the power system and the incorporation of generation from renewable energy sources recessitates faster state estimation in the smart grid. Distributed state estimation (DSE) has become a promising and scalable solution to this urgent demand. In this paper, we investigate the regionalization algorithms for the power system, a necessary step before distributed state estimation can be performed. To the best of the authors' knowledge, this is the first investigation on automatic regionalization (AR). We propose three spectral clustering based AR algorithms. Simulations show that our proposed algorithms outperform the two investigated manual regionalization cases. With the helpmore » of AR algorithms, we also show how the number of regions impacts the accuracy and convergence speed of the DSE and conclude that the number of regions needs to be chosen carefully to improve the convergence speed of DSEs.« less
Husain, Nazim; Mahmood, Riaz
2017-08-01
The toxicity of hexavalent chromium [Cr(VI)] in biological systems is thought to be closely associated with the generation of free radicals and reactive oxygen species. These species are produced when Cr(VI) is reduced to its trivalent form in the cell. This process results in oxidative stress due to an imbalance between the detoxifying ability of the cell and the production of free radicals. We have studied the effect of potassium dichromate (K 2 Cr 2 O 7 ), a [Cr(VI)] compound, on the antioxidant power of human erythrocytes and lymphocytes under in vitro conditions. Incubation of erythrocytes and lymphocytes with different concentrations of K 2 Cr 2 O 7 resulted in a marked dose-dependent decrease in reduced glutathione and an increase in oxidized glutathione and reactive oxygen species levels. The antioxidant power of the cells was decreased, as determined by metal reducing and free radical quenching assays. These results show that [Cr(VI)] upregulates the generation of reactive oxygen species and, as a consequence, the cellular antioxidant defences are compromised. The resulting oxidative stress may contribute to Cr(VI)-induced cellular damage.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bokhari, Ishtiaq H.
2004-12-15
The Pakistan Research Reactor-1 (PARR-1) was converted from highly enriched uranium (HEU) to low-enriched uranium (LEU) fuel in 1991. The reactor is running successfully, with an upgraded power level of 10 MW. To save money on the purchase of costly fresh LEU fuel elements, the use of less burnt HEU spent fuel elements along with the present LEU fuel elements is being considered. The proposal calls for the HEU fuel elements to be placed near the thermal column to gain the required excess reactivity. In the present study the safety analysis of a proposed mixed-fuel core has been carried outmore » at a calculated steady-state power level of 9.8 MW. Standard computer codes and correlations were employed to compute various parameters. Initiating events in reactivity-induced accidents involve various modes of reactivity insertion, namely, start-up accident, accidental drop of a fuel element on the core, flooding of a beam tube with water, and removal of an in-pile experiment during reactor operation. For each of these transients, time histories of reactor power, energy released, temperature, and reactivity were determined.« less
Startup of RAPID-L Lunar Base Reactor by Lithium Release Module
NASA Astrophysics Data System (ADS)
Kambe, Mitsuru
The 200 kWe uranium-nitride fueled lithium cooled fast reactor concept RAPID-L to be combined with thermoelectric power conversion system for lunar base power system is demonstrated. Unique challenges in reactivity control systems design have been attempted in RAPID-L concept. The reactor involves the following innovative reactivity control systems: Lithium Expansion Modules (LEM) for inherent reactivity feedback, Lithium Injection Modules (LIM) for inherent ultimate shutdown, and Lithium Release Modules (LRM) for automated reactor startup. All these systems adopt lithium-6 as a liquid poison instead of conventional B4C rods or Be reflectors. These systems are effective independent of the magnitude and direction of the gravity force. In 2006, however, the following design amendment has been made. 1) B4C poison rods were added to ensure criticality safety in unintended positive reactivity insertion by LRMs due to fire in the launch phase accident; because LRM freeze seal melts at 800°C which result in positive reactivity insertion. 2) Lower hot standby temperature of 200°C was adopted instead of conventional 800°C to reduce the external power at the startup. In this paper, development of the LRM orifice which dominates the startup transient of RAPID-L is discussed. An attention was focused how to achieve sufficiently small flow rate of 6Li in the orifice because it enables moderate positive reactivity insertion rate. The LRM orifice performance has been confirmed using 0.5 mm diameter SUS316 orifice/lithium flow test setup in the glove box.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuz'micheva, K. I.; Merzlyakov, A. S.; Fokin, G. G.
2013-05-15
The reasons for circuit-breaker failures during repeated disconnection of 500 - 750 kV overhead lines with shunt reactors in a cycle of unsuccessful three-phase automatic reconnection (TARC) are analyzed. Recommendations are made for increasing the operating reliability of power transmission lines with shunt reactors when there is unsuccessful reconnection.
NASA Astrophysics Data System (ADS)
How, Soo Ren; Nayan, Nafarizal; Khairul Ahmad, Mohd; Fhong Soon, Chin; Zainizan Sahdan, Mohd; Lias, Jais; Shuhaimi Abu Bakar, Ahmad; Arshad, Mohd Khairuddin Md; Hashim, Uda; Yazid Ahmad, Mohd
2018-04-01
The ion, electron density and electron temperature during formation of TiN films in reactive magnetron sputtering system have been investigated for various settings of radio frequency (RF) power and working pressure by using Langmuir probe measurements. The RF power and working pressure able to affect the densities and plasma properties during the deposition process. In this work, a working pressure (100 and 20 mTorr) and RF power (100, 150 and 200 W) have been used for data acquisition of probe measurement. Fundamental of studied on sputter deposition is very important for improvement of film quality and deposition rate. Higher working pressure and RF power able to produce a higher ion density and reduction of electron temperature.
Development of a reactive-dispersive plume model
NASA Astrophysics Data System (ADS)
Kim, Hyun S.; Kim, Yong H.; Song, Chul H.
2017-04-01
A reactive-dispersive plume model (RDPM) was developed in this study. The RDPM can consider two main components of large-scale point source plume: i) turbulent dispersion and ii) photochemical reactions. In order to evaluate the simulation performance of newly developed RDPM, the comparisons between the model-predicted and observed mixing ratios were made using the TexAQS II 2006 (Texas Air Quality Study II 2006) power-plant experiment data. Statistical analyses show good correlation (0.61≤R≤0.92), and good agreement with the Index of Agreement (0.70≤R≤0.95). The chemical NOx lifetimes for two power-plant plumes (Monticello and Welsh power plants) were also estimated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
MM Hall
2006-01-31
A major materials selection and qualification issue identified in the Space Materials Plan is the potential for creating materials compatibility problems by combining dissimilar reactor core, Brayton Unit and other power conversion plant materials in a recirculating, inert He/Xe gas loop containing reactive impurity gases. Reported here are results of equilibrium thermochemical analyses that address the compatibility of space nuclear power plant (SNPP) materials in high temperature impure He gas environments. These studies provide early information regarding the constraints that exist for SNPP materials selection and provide guidance for establishing test objectives and environments for SNPP materials qualification testing.
Sacheli, Lucia Maria; Christensen, Andrea; Giese, Martin A; Taubert, Nick; Pavone, Enea Francesco; Aglioti, Salvatore Maria; Candidi, Matteo
2015-02-17
During social interactions people automatically apply stereotypes in order to rapidly categorize others. Racial differences are among the most powerful cues that drive these categorizations and modulate our emotional and cognitive reactivity to others. We investigated whether implicit racial bias may also shape hand kinematics during the execution of realistic joint actions with virtual in- and out-group partners. Caucasian participants were required to perform synchronous imitative or complementary reach-to-grasp movements with avatars that had different skin color (white and black) but showed identical action kinematics. Results demonstrate that stronger visuo-motor interference (indexed here as hand kinematics differences between complementary and imitative actions) emerged: i) when participants were required to predict the partner's action goal in order to on-line adapt their own movements accordingly; ii) during interactions with the in-group partner, indicating the partner's racial membership modulates interactive behaviors. Importantly, the in-group/out-group effect positively correlated with the implicit racial bias of each participant. Thus visuo-motor interference during joint action, likely reflecting predictive embodied simulation of the partner's movements, is affected by cultural inter-individual differences.
18 CFR 157.218 - Changes in customer name.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Changes in customer name. 157.218 Section 157.218 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... Act for Certain Transactions and Abandonment § 157.218 Changes in customer name. (a) Automatic...
18 CFR 157.218 - Changes in customer name.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Changes in customer name. 157.218 Section 157.218 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... Act for Certain Transactions and Abandonment § 157.218 Changes in customer name. (a) Automatic...
18 CFR 157.218 - Changes in customer name.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Changes in customer name. 157.218 Section 157.218 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... Act for Certain Transactions and Abandonment § 157.218 Changes in customer name. (a) Automatic...
30 CFR 75.825 - Power centers.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., and be designed and installed as follows: (1) Rated for the maximum phase-to-phase voltage of the circuit; (2) Rated for the full-load current of the circuit that is supplied power through the device. (3... current of the circuit or causes the current to be interrupted automatically before the disconnecting...
Security region-based small signal stability analysis of power systems with FSIG based wind farm
NASA Astrophysics Data System (ADS)
Qin, Chao; Zeng, Yuan; Yang, Yang; Cui, Xiaodan; Xu, Xialing; Li, Yong
2018-02-01
Based on the Security Region approach, the impact of fixed-speed induction generator based wind farm on the small signal stability of power systems is analyzed. Firstly, the key factors of wind farm on the small signal stability of power systems are analyzed and the parameter space for small signal stability region is formed. Secondly, the small signal stability region of power systems with wind power is established. Thirdly, the corresponding relation between the boundary of SSSR and the dominant oscillation mode is further studied. Results show that the integration of fixed-speed induction generator based wind farm will cause the low frequency oscillation stability of the power system deteriorate. When the output of wind power is high, the oscillation stability of the power system is mainly concerned with the inter-area oscillation mode caused by the integration of the wind farm. Both the active power output and the capacity of reactive power compensation of the wind farm have a significant influence on the SSSR. To improve the oscillation stability of power systems with wind power, it is suggested to reasonably set the reactive power compensation capacity for the wind farm through SSSR.
Inexpensive automated paging system for use at remote research sites
Sargent, S.L.; Dey, W.S.; Keefer, D.A.
1998-01-01
The use of a flow-activated automatic sampler at a remote research site required personnel to periodically visit the site to collect samples and reset the automatic sampler. To reduce site visits, a cellular telephone was modified for activation by a datalogger. The purpose of this study was to demonstrate the use and benefit of the modified telephone. Both the power switch and the speed-dial button on the telephone were bypassed and wired to a relay driver. The datalogger was programmed to compare values of a monitored environmental parameter with a target value. When the target value was reached or exceeded, the datalogger pulsed a relay driver, activating power to the telephone. A separate relay activated the speed dial, dialing the number of a tone-only pager. The use of this system has saved time and reduced travel costs by reducing the number of trips to the site, without the loss of any data.The use of a flow-activated automatic sampler at a remote research site required personnel to periodically visit the site to collect samples and reset the automatic sampler. To reduce site visits, a cellular telephone was modified for activation by a datalogger. The purpose of this study was to demonstrate the use and benefit of the modified telephone. Both the power switch and the speed-dial button on the telephone were bypassed and wired to a relay driver. The datalogger was programmed to compare values of a monitored environmental parameter with a target value. When the target value was reached or exceeded, the datalogger pulsed a relay driver, activating power to the telephone. A separate relay activated the speed dial, dialing the number of a tone-only pager. The use of this system has saved time and reduced travel costs by reducing the number of trips to the site, without the loss of any data.
Wave Power Demonstration Project at Reedsport, Oregon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mekhiche, Mike; Downie, Bruce
2013-10-21
Ocean wave power can be a significant source of large‐scale, renewable energy for the US electrical grid. The Electrical Power Research Institute (EPRI) conservatively estimated that 20% of all US electricity could be generated by wave energy. Ocean Power Technologies, Inc. (OPT), with funding from private sources and the US Navy, developed the PowerBuoy to generate renewable energy from the readily available power in ocean waves. OPT's PowerBuoy converts the energy in ocean waves to electricity using the rise and fall of waves to move the buoy up and down (mechanical stroking) which drives an electric generator. This electricity ismore » then conditioned and transmitted ashore as high‐voltage power via underwater cable. OPT's wave power generation system includes sophisticated techniques to automatically tune the system for efficient conversion of random wave energy into low cost green electricity, for disconnecting the system in large waves for hardware safety and protection, and for automatically restoring operation when wave conditions normalize. As the first utility scale wave power project in the US, the Wave Power Demonstration Project at Reedsport, OR, will consist of 10 PowerBuoys located 2.5 miles off the coast. This U.S. Department of Energy Grant funding along with funding from PNGC Power, an Oregon‐based electric power cooperative, was utilized for the design completion, fabrication, assembly and factory testing of the first PowerBuoy for the Reedsport project. At this time, the design and fabrication of this first PowerBuoy and factory testing of the power take‐off subsystem are complete; additionally the power take‐off subsystem has been successfully integrated into the spar.« less
NASA Technical Reports Server (NTRS)
Schilling, D. L.; Oh, S. J.; Thau, F.
1975-01-01
Developments in communications systems, computer systems, and power distribution systems for the space shuttle are described. The use of high speed delta modulation for bit rate compression in the transmission of television signals is discussed. Simultaneous Multiprocessor Organization, an approach to computer organization, is presented. Methods of computer simulation and automatic malfunction detection for the shuttle power distribution system are also described.
2006-12-31
dependence, and estimated mass of the stack. The model equations were derived from peer reviewed academic journals , internal studies, and texts on the subject...Liu, R. Dougal, E. Solodovnik, "VTB-Based Design of a Standalone Photovoltaic Power System", International Journal of Green Energy, Vol. 1, No. 3...Powered Battery Chargers 17 Exergy minimization 19 Use of secondary cells as temporary energy repositories 19 Design an automatic energy optimization
Integrated Inverter And Battery Charger
NASA Technical Reports Server (NTRS)
Rippel, Wally E.
1988-01-01
Circuit combines functions of dc-to-ac inversion (for driving ac motor in battery-powered vehicle) and ac-to-dc conversion (for charging battery from ac line when vehicle not in use). Automatically adapts to either mode. Design of integrated inverter/charger eliminates need for duplicate components, saves space, reduces weight and cost of vehicle. Advantages in other applications : load-leveling systems, standby ac power systems, and uninterruptible power supplies.
76 FR 26282 - Buckeye Power, Inc.; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-06
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL11-36-000] Buckeye Power...) (2010), Buckeye Power, Inc. (Buckeye) filed a petition for acceptance or approval of its monthly revenue requirement for its contribution to the supply of Reactive Power and Voltage Control from Generation Sources...
Ultrafast impact dynamics of reactive materials (Dlott)
2013-04-16
Kalia, A. Nakano, B. E. Hohman, and K. L. McNesby, Multimillion atom reactive simulations of nanostructured energetic materials, J. Propul. Power 23...34Materials for Energy Applications - Experiment, Modeling and Simulations ", Mar. 2011, Los Angeles, CA. 7. (invited) Studium Conference on in situ...intermetallics. 7,20-24 The dynamics of conventional reactive materials containing micron to millimeter particles are usually viewed within a
G T-Mohr Start-up Reactivity Insertion Transient Analysis Using Simulink
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fard, Mehdi Reisi; Blue, Thomas E.; Miller, Don W.
2006-07-01
As a part of a Department of Energy-Nuclear Engineering Research Initiative (NERI) Project, we at OSU are investigating SiC semiconductor detectors as neutron power monitors for Generation IV power reactors. As a part of this project, we are investigating the power monitoring requirements for a specific type of Generation IV reactor, namely the GT-MHR. To evaluate the power monitoring requirements for the GT-MHR that are most demanding for a SiC diode power monitor, we have developed a Simulink model to study the transient behavior of the GT-MHR. In this paper, we describe the application of the Simulink code to themore » analysis of a series of Start-up Reactivity Insertion Transients (SURITs). The SURIT is considered to be a limiting protectable accident in terms of establishing the dynamic range of a SiC power monitor because of the low count rate of the detector during the start-up and absence of the reactivity feedback mechanism at the beginning of transient. The SURIT is studied with the ultimate goal of identifying combinations of 1) reactor power scram setpoints and 2) cram initiation times (the time in which a scram must be initiated once the setpoint is exceeded) for which the GT-MHR core is protected in the event of a continuous withdrawal of a control rod bank from the core from low powers. The SURIT is initiated by withdrawing a rod bank when the reactor is cold (300 K) and sub-critical at the BOEC (Beginning of Equilibrium Cycle) condition. Various initial power levels have been considered corresponding to various degrees of sub-criticality and various source strengths. An envelope of response is determined to establish which initial powers correspond to the worst case SURIT. (authors)« less
Split-core heat-pipe reactors for out-of-pile thermionic power systems.
NASA Technical Reports Server (NTRS)
Niederauer, G.; Lantz, E.; Breitweiser, R.
1971-01-01
Description of the concept of splitting a heat-pipe reactor for out-of-core thermionics into two identical halves and using the resulting center gap for reactivity control. Short Li-W reactor heat pipes penetrate the axial reflectors and form a heat exchanger with long heat pipes which wind through the shield to the thermionic diodes. With one reactor half anchored to the shield, the other is attached to a long arm with a pivot behind the shield and swings through a small arc for reactivity control. A safety shim prevents large reactivity inputs, and a fueled control arm drive shaft acts as a power stabilizer. Reactors fueled with U-235C and with U-233C have been studied.-
NASA Astrophysics Data System (ADS)
Duan, Jiandong; Fan, Shaogui; Wu, Fengjiang; Sun, Li; Wang, Guanglin
2018-06-01
This paper proposes an instantaneous power control method for high speed permanent magnet synchronous generators (PMSG), to realize the decoupled control of active power and reactive power, through vector control based on a sliding mode observer (SMO), and a phase locked loop (PLL). Consequently, the high speed PMSG has a high internal power factor, to ensure efficient operation. Vector control and accurate estimation of the instantaneous power require an accurate estimate of the rotor position. The SMO is able to estimate the back electromotive force (EMF). The rotor position and speed can be obtained using a combination of the PLL technique and the phase compensation method. This method has the advantages of robust operation, and being resistant to noise when estimating the position of the rotor. Using instantaneous power theory, the relationship between the output active power, reactive power, and stator current of the PMSG is deduced, and the power constraint condition is analysed for operation at the unit internal power factor. Finally, the accuracy of the rotor position detection, the instantaneous power detection, and the control methods are verified using simulations and experiments.
SELF-REGULATING BOILING-WATER NUCLEAR REACTORS
Ransohoff, J.A.; Plawchan, J.D.
1960-08-16
A boiling-water reactor was designed which comprises a pressure vessel containing a mass of water, a reactor core submerged within the water, a reflector tank disposed within the reactor, the reflector tank being open at the top to the interior of the pressure vessel, and a surge tank connected to the reflector tank. In operation the reflector level changes as a function of the pressure witoin the reactor so that the reactivity of the reactor is automatically controlled.
Link Correlated Military Data for Better Decision Support
2011-06-01
automatically translated into URI based links, thus can greatly reduce man power cost on software development. 3 Linked Data Technique Tim Berners - Lee ...Linked Data - while Linked Data is usually considered as part of Semantic Web, or “the Semantic Web done right” as described by Tim himself - has been...Required data of automatic link construction mechanism on more kinds of correlations. References [1] B. L. Tim , “The next Web of open, linked data
Automatic insulation resistance testing apparatus
Wyant, Francis J.; Nowlen, Steven P.; Luker, Spencer M.
2005-06-14
An apparatus and method for automatic measurement of insulation resistances of a multi-conductor cable. In one embodiment of the invention, the apparatus comprises a power supply source, an input measuring means, an output measuring means, a plurality of input relay controlled contacts, a plurality of output relay controlled contacts, a relay controller and a computer. In another embodiment of the invention the apparatus comprises a power supply source, an input measuring means, an output measuring means, an input switching unit, an output switching unit and a control unit/data logger. Embodiments of the apparatus of the invention may also incorporate cable fire testing means. The apparatus and methods of the present invention use either voltage or current for input and output measured variables.
Engine combustion control via fuel reactivity stratification
Reitz, Rolf Deneys; Hanson, Reed M.; Splitter, Derek A.; Kokjohn, Sage L.
2015-07-14
A compression ignition engine uses two or more fuel charges having two or more reactivities to control the timing and duration of combustion. In a preferred implementation, a lower-reactivity fuel charge is injected or otherwise introduced into the combustion chamber, preferably sufficiently early that it becomes at least substantially homogeneously dispersed within the chamber before a subsequent injection is made. One or more subsequent injections of higher-reactivity fuel charges are then made, and these preferably distribute the higher-reactivity matter within the lower-reactivity chamber space such that combustion begins in the higher-reactivity regions, and with the lower-reactivity regions following thereafter. By appropriately choosing the reactivities of the charges, their relative amounts, and their timing, combustion can be tailored to achieve optimal power output (and thus fuel efficiency), at controlled temperatures (and thus controlled NOx), and with controlled equivalence ratios (and thus controlled soot).
Engine combustion control via fuel reactivity stratification
Reitz, Rolf Deneys; Hanson, Reed M.; Splitter, Derek A.; Kokjohn, Sage L.
2016-06-28
A compression ignition engine uses two or more fuel charges having two or more reactivities to control the timing and duration of combustion. In a preferred implementation, a lower-reactivity fuel charge is injected or otherwise introduced into the combustion chamber, preferably sufficiently early that it becomes at least substantially homogeneously dispersed within the chamber before a subsequent injection is made. One or more subsequent injections of higher-reactivity fuel charges are then made, and these preferably distribute the higher-reactivity matter within the lower-reactivity chamber space such that combustion begins in the higher-reactivity regions, and with the lower-reactivity regions following thereafter. By appropriately choosing the reactivities of the charges, their relative amounts, and their timing, combustion can be tailored to achieve optimal power output (and thus fuel efficiency), at controlled temperatures (and thus controlled NOx), and with controlled equivalence ratios (and thus controlled soot).
Engine combustion control via fuel reactivity stratification
Reitz, Rolf Deneys; Hanson, Reed M; Splitter, Derek A; Kokjohn, Sage L
2013-12-31
A compression ignition engine uses two or more fuel charges having two or more reactivities to control the timing and duration of combustion. In a preferred implementation, a lower-reactivity fuel charge is injected or otherwise introduced into the combustion chamber, preferably sufficiently early that it becomes at least substantially homogeneously dispersed within the chamber before a subsequent injection is made. One or more subsequent injections of higher-reactivity fuel charges are then made, and these preferably distribute the higher-reactivity matter within the lower-reactivity chamber space such that combustion begins in the higher-reactivity regions, and with the lower-reactivity regions following thereafter. By appropriately choose the reactivities of the charges, their relative amounts, and their timing, combustion can be tailored to achieve optimal power output (and thus fuel efficiency), at controlled temperatures (and thus controlled NOx), and with controlled equivalence ratios (and thus controlled soot).
Research on Application of Automatic Weather Station Based on Internet of Things
NASA Astrophysics Data System (ADS)
Jianyun, Chen; Yunfan, Sun; Chunyan, Lin
2017-12-01
In this paper, the Internet of Things is briefly introduced, and then its application in the weather station is studied. A method of data acquisition and transmission based on NB-iot communication mode is proposed, Introduction of Internet of things technology, Sensor digital and independent power supply as the technical basis, In the construction of Automatic To realize the intelligent interconnection of the automatic weather station, and then to form an automatic weather station based on the Internet of things. A network structure of automatic weather station based on Internet of things technology is constructed to realize the independent operation of intelligent sensors and wireless data transmission. Research on networking data collection and dissemination of meteorological data, through the data platform for data analysis, the preliminary work of meteorological information publishing standards, networking of meteorological information receiving terminal provides the data interface, to the wisdom of the city, the wisdom of the purpose of the meteorological service.
[Development of a Compared Software for Automatically Generated DVH in Eclipse TPS].
Xie, Zhao; Luo, Kelin; Zou, Lian; Hu, Jinyou
2016-03-01
This study is to automatically calculate the dose volume histogram(DVH) for the treatment plan, then to compare it with requirements of doctor's prescriptions. The scripting language Autohotkey and programming language C# were used to develop a compared software for automatically generated DVH in Eclipse TPS. This software is named Show Dose Volume Histogram (ShowDVH), which is composed of prescription documents generation, operation functions of DVH, software visualization and DVH compared report generation. Ten cases in different cancers have been separately selected, in Eclipse TPS 11.0 ShowDVH could not only automatically generate DVH reports but also accurately determine whether treatment plans meet the requirements of doctor’s prescriptions, then reports gave direction for setting optimization parameters of intensity modulated radiated therapy. The ShowDVH is an user-friendly and powerful software, and can automatically generated compared DVH reports fast in Eclipse TPS 11.0. With the help of ShowDVH, it greatly saves plan designing time and improves working efficiency of radiation therapy physicists.
The use of automatic programming techniques for fault tolerant computing systems
NASA Technical Reports Server (NTRS)
Wild, C.
1985-01-01
It is conjectured that the production of software for ultra-reliable computing systems such as required by Space Station, aircraft, nuclear power plants and the like will require a high degree of automation as well as fault tolerance. In this paper, the relationship between automatic programming techniques and fault tolerant computing systems is explored. Initial efforts in the automatic synthesis of code from assertions to be used for error detection as well as the automatic generation of assertions and test cases from abstract data type specifications is outlined. Speculation on the ability to generate truly diverse designs capable of recovery from errors by exploring alternate paths in the program synthesis tree is discussed. Some initial thoughts on the use of knowledge based systems for the global detection of abnormal behavior using expectations and the goal-directed reconfiguration of resources to meet critical mission objectives are given. One of the sources of information for these systems would be the knowledge captured during the automatic programming process.
Preliminary neutronic analysis of a cavity test reactor
NASA Technical Reports Server (NTRS)
Whitmarsh, C. L., Jr.
1973-01-01
A reference configuration was calculated for a cavity test reactor to be used for testing the gascore nuclear rocket concept. A thermal flux of 4.1 x 10 to the 14th power neutrons per square centimeter per second in the cavity was provided by a driver fuel loading of 6.4 kg of enriched uranium in MTR fuel elements. The reactor was moderated and cooled by heavy water and reflected with 25.4 cm of beryllium. Power generation of 41.3 MW in the driver fuel is rejected to a heat sink. Design effort was directed toward minimization of driver power while maintaining 2.7 MW in the cavity during a test run. Ancillary data on material reactivity worths, reactivity coefficients, flux spectra, and power distributions are reported.
Automatic sleep scoring: a search for an optimal combination of measures.
Krakovská, Anna; Mezeiová, Kristína
2011-09-01
The objective of this study is to find the best set of characteristics of polysomnographic signals for the automatic classification of sleep stages. A selection was made from 74 measures, including linear spectral measures, interdependency measures, and nonlinear measures of complexity that were computed for the all-night polysomnographic recordings of 20 healthy subjects. The adopted multidimensional analysis involved quadratic discriminant analysis, forward selection procedure, and selection by the best subset procedure. Two situations were considered: the use of four polysomnographic signals (EEG, EMG, EOG, and ECG) and the use of the EEG alone. For the given database, the best automatic sleep classifier achieved approximately an 81% agreement with the hypnograms of experts. The classifier was based on the next 14 features of polysomnographic signals: the ratio of powers in the beta and delta frequency range (EEG, channel C3), the fractal exponent (EMG), the variance (EOG), the absolute power in the sigma 1 band (EEG, C3), the relative power in the delta 2 band (EEG, O2), theta/gamma (EEG, C3), theta/alpha (EEG, O1), sigma/gamma (EEG, C4), the coherence in the delta 1 band (EEG, O1-O2), the entropy (EMG), the absolute theta 2 (EEG, Fp1), theta/alpha (EEG, Fp1), the sigma 2 coherence (EEG, O1-C3), and the zero-crossing rate (ECG); however, even with only four features, we could perform sleep scoring with a 74% accuracy, which is comparable to the inter-rater agreement between two independent specialists. We have shown that 4-14 carefully selected polysomnographic features were sufficient for successful sleep scoring. The efficiency of the corresponding automatic classifiers was verified and conclusively demonstrated on all-night recordings from healthy adults. Copyright © 2011 Elsevier B.V. All rights reserved.
Power oscillation suppression by robust SMES in power system with large wind power penetration
NASA Astrophysics Data System (ADS)
Ngamroo, Issarachai; Cuk Supriyadi, A. N.; Dechanupaprittha, Sanchai; Mitani, Yasunori
2009-01-01
The large penetration of wind farm into interconnected power systems may cause the severe problem of tie-line power oscillations. To suppress power oscillations, the superconducting magnetic energy storage (SMES) which is able to control active and reactive powers simultaneously, can be applied. On the other hand, several generating and loading conditions, variation of system parameters, etc., cause uncertainties in the system. The SMES controller designed without considering system uncertainties may fail to suppress power oscillations. To enhance the robustness of SMES controller against system uncertainties, this paper proposes a robust control design of SMES by taking system uncertainties into account. The inverse additive perturbation is applied to represent the unstructured system uncertainties and included in power system modeling. The configuration of active and reactive power controllers is the first-order lead-lag compensator with single input feedback. To tune the controller parameters, the optimization problem is formulated based on the enhancement of robust stability margin. The particle swarm optimization is used to solve the problem and achieve the controller parameters. Simulation studies in the six-area interconnected power system with wind farms confirm the robustness of the proposed SMES under various operating conditions.
Results of the harmonics measurement program at the John F. Long photovoltaic house
NASA Astrophysics Data System (ADS)
Campen, G. L.
1982-03-01
Photovoltaic (PV) systems used in single-family dwellings require an inverter to act as an interface between the direct-current (dc) power output of the PV unit and the alternating-current (ac) power needed by house loads. A type of inverter known as line commutated injects harmonic currents on the ac side and requires large amounts of reactive power. Large numbers of such PV installations could lead to unacceptable levels of harmonic voltages on the utility system, and the need to increase the utility's deliver of reactive power could result in significant cost increases. The harmonics and power-factor effects are examined for a single PV installation using a line-commutated inverter. The magnitude and phase of various currents and voltages from the fundamental to the 13th harmonic were recorded both with and without the operation of the PV system.
A Computer Model for Teaching the Dynamic Behavior of AC Contactors
ERIC Educational Resources Information Center
Ruiz, J.-R. R.; Espinosa, A. G.; Romeral, L.
2010-01-01
Ac-powered contactors are extensively used in industry in applications such as automatic electrical devices, motor starters, and heaters. In this work, a practical session that allows students to model and simulate the dynamic behavior of ac-powered electromechanical contactors is presented. Simulation is carried out using a rigorous parametric…
Remotely-interrogated high data rate free space laser communications link
Ruggiero, Anthony J [Livermore, CA
2007-05-29
A system and method of remotely extracting information from a communications station by interrogation with a low power beam. Nonlinear phase conjugation of the low power beam results in a high power encoded return beam that automatically tracks the input beam and is corrected for atmospheric distortion. Intracavity nondegenerate four wave mixing is used in a broad area semiconductor laser in the communications station to produce the return beam.
Optimal Transmission Line Switching under Geomagnetic Disturbances
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Mowen; Nagarajan, Harsha; Yamangil, Emre
Recently, there have been increasing concerns about how geomagnetic disturbances (GMDs) impact electrical power systems. Geomagnetically-induced currents (GICs) can saturate transformers, induce hot spot heating and increase reactive power losses. These effects can potentially cause catastrophic damage to transformers and severely impact the ability of a power system to deliver power. To address this problem, we develop a model of GIC impacts to power systems that includes 1) GIC thermal capacity of transformers as a function of normal Alternating Current (AC) and 2) reactive power losses as a function of GIC. We also use this model to derive an optimizationmore » problem that protects power systems from GIC impacts through line switching, generator dispatch, and load shedding. We then employ state-of-the-art convex relaxations of AC power flow equations to lower bound the objective. We demonstrate the approach on a modified RTS96 system and UIUC 150-bus system and show that line switching is an effective means to mitigate GIC impacts. We also provide a sensitivity analysis of decisions with respect to GMD direction.« less
Optimal Transmission Line Switching under Geomagnetic Disturbances
Lu, Mowen; Nagarajan, Harsha; Yamangil, Emre; ...
2017-10-11
Recently, there have been increasing concerns about how geomagnetic disturbances (GMDs) impact electrical power systems. Geomagnetically-induced currents (GICs) can saturate transformers, induce hot spot heating and increase reactive power losses. These effects can potentially cause catastrophic damage to transformers and severely impact the ability of a power system to deliver power. To address this problem, we develop a model of GIC impacts to power systems that includes 1) GIC thermal capacity of transformers as a function of normal Alternating Current (AC) and 2) reactive power losses as a function of GIC. We also use this model to derive an optimizationmore » problem that protects power systems from GIC impacts through line switching, generator dispatch, and load shedding. We then employ state-of-the-art convex relaxations of AC power flow equations to lower bound the objective. We demonstrate the approach on a modified RTS96 system and UIUC 150-bus system and show that line switching is an effective means to mitigate GIC impacts. We also provide a sensitivity analysis of decisions with respect to GMD direction.« less
Direct Estimation of Power Distribution in Reactors for Nuclear Thermal Space Propulsion
NASA Astrophysics Data System (ADS)
Aldemir, Tunc; Miller, Don W.; Burghelea, Andrei
2004-02-01
A recently proposed constant temperature power sensor (CTPS) has the capability to directly measure the local power deposition rate in nuclear reactor cores proposed for space thermal propulsion. Such a capability reduces the uncertainties in the estimated power peaking factors and hence increases the reliability of the nuclear engine. The CTPS operation is sensitive to the changes in the local thermal conditions. A procedure is described for the automatic on-line calibration of the sensor through estimation of changes in thermal .conditions.
Trends in Atmospheric Reactive Nitrogen for the Eastern United States
Reactive nitrogen can travel far from emission sources and impact sensitive ecosystems. From 2002-2006, policy actions have led to decreases in NOx emissions from power plants and motor vehicles. In this study, atmospheric chemical transport modeling demonstrates tha...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uematsu, Hitoshi; Yamamoto, Toru; Izutsu, Sadayuki
1990-06-01
A reactivity-initiated event is a design-basis accident for the safety analysis of boiling water reactors. It is defined as a rapid transient of reactor power caused by a reactivity insertion of over $1.0 due to a postulated drop or abnormal withdrawal of the control rod from the core. Strong space-dependent feedback effects are associated with the local power increase due to control rod movement. A realistic treatment of the core status in a transient by a code with a detailed core model is recommended in evaluating this event. A three-dimensional transient code, ARIES, has been developed to meet this need.more » The code simulates the event with three-dimensional neutronics, coupled with multichannel thermal hydraulics, based on a nonequilibrium separated flow model. The experimental data obtained in reactivity accident tests performed with the SPERT III-E core are used to verify the entire code, including thermal-hydraulic models.« less
77 FR 47059 - Southern Illinois Power Cooperative; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-07
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL12-92-000] Southern Illinois Power Cooperative; Notice of Filing Take notice that on July 30, 2012, Southern Illinois Power Cooperative filed a Proposed Revenue Requirement for reactive supply service under Midwest Independent...
NASA Astrophysics Data System (ADS)
Xu, Chen; Zhou, Bao-Rong; Zhai, Jian-Wei; Zhang, Yong-Jun; Yi, Ying-Qi
2017-05-01
In order to solve the problem of voltage exceeding specified limits and improve the penetration of photovoltaic in distribution network, we can make full use of the active power regulation ability of energy storage(ES) and the reactive power regulation ability of grid-connected photovoltaic inverter to provide support of active power and reactive power for distribution network. A strategy of actively controlling the output power for photovoltaic-storage system based on extended PQ-QV-PV node by analyzing the voltage regulating mechanism of point of commom coupling(PCC) of photovoltaic with energy storage(PVES) by controlling photovoltaic inverter and energy storage. The strategy set a small wave range of voltage to every photovoltaic by making the type of PCC convert among PQ, PV and QV. The simulation results indicate that the active control method can provide a better solution to the problem of voltage exceeding specified limits when photovoltaic is connectted to electric distribution network.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shayestehaminzadeh, Seyedmohammad, E-mail: ses30@hi.is, E-mail: shayesteh@mch.rwth-aachen.de; Arnalds, Unnar B.; Magnusson, Rögnvaldur L.
2015-11-15
This paper reports the observation of a periodic runaway of plasma to a higher density for the reactive discharge of the target material (Ti) with moderate sputter yield. Variable emission of secondary electrons, for the alternating transition of the target from metal mode to oxide mode, is understood to be the main reason for the runaway occurring periodically. Increasing the pulsing frequency can bring the target back to a metal (or suboxide) mode, and eliminate the periodic transition of the target. Therefore, a pulsing frequency interval is defined for the reactive Ar/O{sub 2} discharge in order to sustain the plasmamore » in a runaway-free mode without exceeding the maximum power that the magnetron can tolerate.« less
Sensation-Seeking and Impulsivity as Predictors of Reactive and Proactive Aggression in Adolescents
Pérez Fuentes, María Del Carmen; Molero Jurado, Maria del Mar; Carrión Martínez, José J.; Mercader Rubio, Isabel; Gázquez, José J.
2016-01-01
In adolescence, such matters as substance use and impulsiveness may give rise to problematic behavior repertoires. This study was therefore done to analyze the predictive value of sensation-seeking and impulsiveness dimensions related to the functions of aggression (reactive/proactive) and types of expression (physical/relational). A total of 822 high school students in Almeria (Spain) aged 13–18, were administered the Sensation-Seeking Scale, the State Impulsiveness Scale and Peer Conflict Scale. The results show the existence of a positive correlation of the majority of factors analyzed, both in impulsiveness and sensation-seeking, with respect to the different types of aggression. Furthermore, aggressive behavior is explained by the combination of a sensation-seeking factor (Disinhibition) and two impulsiveness factors (Gratification and Automatism). This study shows the need to analyze aggression as a multidimensional construct. PMID:27729883
Darda, Kohinoor M; Butler, Emily E; Ramsey, Richard
2018-06-01
Humans show an involuntary tendency to copy other people's actions. Although automatic imitation builds rapport and affiliation between individuals, we do not copy actions indiscriminately. Instead, copying behaviors are guided by a selection mechanism, which inhibits some actions and prioritizes others. To date, the neural underpinnings of the inhibition of automatic imitation and differences between the sexes in imitation control are not well understood. Previous studies involved small sample sizes and low statistical power, which produced mixed findings regarding the involvement of domain-general and domain-specific neural architectures. Here, we used data from Experiment 1 ( N = 28) to perform a power analysis to determine the sample size required for Experiment 2 ( N = 50; 80% power). Using independent functional localizers and an analysis pipeline that bolsters sensitivity, during imitation control we show clear engagement of the multiple-demand network (domain-general), but no sensitivity in the theory-of-mind network (domain-specific). Weaker effects were observed with regard to sex differences, suggesting that there are more similarities than differences between the sexes in terms of the neural systems engaged during imitation control. In summary, neurocognitive models of imitation require revision to reflect that the inhibition of imitation relies to a greater extent on a domain-general selection system rather than a domain-specific system that supports social cognition.
Foundations for Streaming Model Transformations by Complex Event Processing.
Dávid, István; Ráth, István; Varró, Dániel
2018-01-01
Streaming model transformations represent a novel class of transformations to manipulate models whose elements are continuously produced or modified in high volume and with rapid rate of change. Executing streaming transformations requires efficient techniques to recognize activated transformation rules over a live model and a potentially infinite stream of events. In this paper, we propose foundations of streaming model transformations by innovatively integrating incremental model query, complex event processing (CEP) and reactive (event-driven) transformation techniques. Complex event processing allows to identify relevant patterns and sequences of events over an event stream. Our approach enables event streams to include model change events which are automatically and continuously populated by incremental model queries. Furthermore, a reactive rule engine carries out transformations on identified complex event patterns. We provide an integrated domain-specific language with precise semantics for capturing complex event patterns and streaming transformations together with an execution engine, all of which is now part of the Viatra reactive transformation framework. We demonstrate the feasibility of our approach with two case studies: one in an advanced model engineering workflow; and one in the context of on-the-fly gesture recognition.
Automatic Generation of Validated Specific Epitope Sets.
Carrasco Pro, Sebastian; Sidney, John; Paul, Sinu; Lindestam Arlehamn, Cecilia; Weiskopf, Daniela; Peters, Bjoern; Sette, Alessandro
2015-01-01
Accurate measurement of B and T cell responses is a valuable tool to study autoimmunity, allergies, immunity to pathogens, and host-pathogen interactions and assist in the design and evaluation of T cell vaccines and immunotherapies. In this context, it is desirable to elucidate a method to select validated reference sets of epitopes to allow detection of T and B cells. However, the ever-growing information contained in the Immune Epitope Database (IEDB) and the differences in quality and subjects studied between epitope assays make this task complicated. In this study, we develop a novel method to automatically select reference epitope sets according to a categorization system employed by the IEDB. From the sets generated, three epitope sets (EBV, mycobacteria and dengue) were experimentally validated by detection of T cell reactivity ex vivo from human donors. Furthermore, a web application that will potentially be implemented in the IEDB was created to allow users the capacity to generate customized epitope sets.
Multimodal Excitatory Interfaces with Automatic Content Classification
NASA Astrophysics Data System (ADS)
Williamson, John; Murray-Smith, Roderick
We describe a non-visual interface for displaying data on mobile devices, based around active exploration: devices are shaken, revealing the contents rattling around inside. This combines sample-based contact sonification with event playback vibrotactile feedback for a rich and compelling display which produces an illusion much like balls rattling inside a box. Motion is sensed from accelerometers, directly linking the motions of the user to the feedback they receive in a tightly closed loop. The resulting interface requires no visual attention and can be operated blindly with a single hand: it is reactive rather than disruptive. This interaction style is applied to the display of an SMS inbox. We use language models to extract salient features from text messages automatically. The output of this classification process controls the timbre and physical dynamics of the simulated objects. The interface gives a rapid semantic overview of the contents of an inbox, without compromising privacy or interrupting the user.
Adaptive Neural Network Algorithm for Power Control in Nuclear Power Plants
NASA Astrophysics Data System (ADS)
Masri Husam Fayiz, Al
2017-01-01
The aim of this paper is to design, test and evaluate a prototype of an adaptive neural network algorithm for the power controlling system of a nuclear power plant. The task of power control in nuclear reactors is one of the fundamental tasks in this field. Therefore, researches are constantly conducted to ameliorate the power reactor control process. Currently, in the Department of Automation in the National Research Nuclear University (NRNU) MEPhI, numerous studies are utilizing various methodologies of artificial intelligence (expert systems, neural networks, fuzzy systems and genetic algorithms) to enhance the performance, safety, efficiency and reliability of nuclear power plants. In particular, a study of an adaptive artificial intelligent power regulator in the control systems of nuclear power reactors is being undertaken to enhance performance and to minimize the output error of the Automatic Power Controller (APC) on the grounds of a multifunctional computer analyzer (simulator) of the Water-Water Energetic Reactor known as Vodo-Vodyanoi Energetichesky Reaktor (VVER) in Russian. In this paper, a block diagram of an adaptive reactor power controller was built on the basis of an intelligent control algorithm. When implementing intelligent neural network principles, it is possible to improve the quality and dynamic of any control system in accordance with the principles of adaptive control. It is common knowledge that an adaptive control system permits adjusting the controller’s parameters according to the transitions in the characteristics of the control object or external disturbances. In this project, it is demonstrated that the propitious options for an automatic power controller in nuclear power plants is a control system constructed on intelligent neural network algorithms.
Suslow, Thomas; Kugel, Harald; Rufer, Michael; Redlich, Ronny; Dohm, Katharina; Grotegerd, Dominik; Zaremba, Dario; Dannlowski, Udo
2016-02-04
Alexithymia is a clinically relevant personality trait related to difficulties in recognizing and describing emotions. Previous studies examining the neural correlates of alexithymia have shown mainly decreased response of several brain areas during emotion processing in healthy samples and patients suffering from autism or post-traumatic stress disorder. In the present study, we examined the effect of alexithymia on automatic brain reactivity to negative and positive facial expressions in clinical depression. Brain activation in response to sad, happy, neutral, and no facial expression (presented for 33 ms and masked by neutral faces) was measured by functional magnetic resonance imaging at 3 T in 26 alexithymic and 26 non-alexithymic patients with major depression. Alexithymic patients manifested less activation in response to masked sad and happy (compared to neutral) faces in right frontal regions and right caudate nuclei than non-alexithymic patients. Our neuroimaging study provides evidence that the personality trait alexithymia has a modulating effect on automatic emotion processing in clinical depression. Our findings support the idea that alexithymia could be associated with functional deficits of the right hemisphere. Future research on the neural substrates of emotion processing in depression should assess and control alexithymia in their analyses.
Mandal, Debasish; Ramanan, Rajeev; Usharani, Dandamudi; Janardanan, Deepa; Wang, Binju; Shaik, Sason
2015-01-21
This article addresses the intriguing hydrogen-abstraction (H-abstraction) and oxygen-transfer (O-transfer) reactivity of a series of nonheme [Fe(IV)(O)(TMC)(Lax)](z+) complexes, with a tetramethyl cyclam ligand and a variable axial ligand (Lax), toward three substrates: 1,4-cyclohexadiene, 9,10-dihydroanthracene, and triphenyl phosphine. Experimentally, O-transfer-reactivity follows the relative electrophilicity of the complexes, whereas the corresponding H-abstraction-reactivity generally increases as the axial ligand becomes a better electron donor, hence exhibiting an antielectrophilic trend. Our theoretical results show that the antielectrophilic trend in H-abstraction is affected by tunneling contributions. Room-temperature tunneling increases with increase of the electron donation power of the axial-ligand, and this reverses the natural electrophilic trend, as revealed through calculations without tunneling, and leads to the observed antielectrophilic trend. By contrast, O-transfer-reactivity, not being subject to tunneling, retains an electrophilic-dependent reactivity trend, as revealed experimentally and computationally. Tunneling-corrected kinetic-isotope effect (KIE) calculations matched the experimental KIE values only if all of the H-abstraction reactions proceeded on the quintet state (S = 2) surface. As such, the present results corroborate the initially predicted two-state reactivity (TSR) scenario for these reactions. The increase of tunneling with the electron-releasing power of the axial ligand, and the reversal of the "natural" reactivity pattern, support the "tunneling control" hypothesis (Schreiner et al., ref 19). Should these predictions be corroborated, the entire field of C-H bond activation in bioinorganic chemistry would lay open to reinvestigation.
Proactive and Reactive Transmission Power Control for Energy-Efficient On-Body Communications
Vallejo, Mónica; Recas, Joaquín.; Ayala, José L.
2015-01-01
In wireless body sensor network (WBSNs), the human body has an important effect on the performance of the communication due to the temporal variations caused and the attenuation and fluctuation of the path loss. This fact suggests that the transmission power must adapt to the current state of the link in a way that it ensures a balance between energy consumption and packet loss. In this paper, we validate our two transmission power level policies (reactive and predictive approaches) using the Castalia simulator. The integration of our experimental measurements in the simulator allows us to easily evaluate complex scenarios, avoiding the difficulties associated with a practical realization. Our results show that both schemes perform satisfactorily, providing overall energy savings of 24% and 22% for a case of study, as compared to the maximum transmission power mode. PMID:25769049
76 FR 5799 - Prairie Power, Inc.; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-02
.... (Midwest ISO) Schedule 2, for reactive supply and voltage control service from certain of its owned... and Midwest ISO requirements for the provision of reactive supply and voltage control under Schedule 2 of the Midwest ISO Open Access Transmission, Energy, and Operating Reserve Markets Tariff, including...
77 FR 47062 - Kentucky Municipal Power Agency; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-07
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL12-94-000] Kentucky Municipal Power Agency; Notice of Filing Take notice that on July 30, 2012, Kentucky Municipal Power Agency filed a Proposed Revenue Requirement for reactive supply service under Midwest Independent Transmission...
77 FR 47060 - Indiana Municipal Power Agency; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-07
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL12-97-000] Indiana Municipal Power Agency; Notice of Filing Take notice that on July 30, 2012, Indiana Municipal Power Agency filed a Proposed Revenue Requirement for reactive supply service under Midwest Independent Transmission...
77 FR 61595 - Southern Illinois Power Cooperative; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-10
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL13-4-000] Southern Illinois Power Cooperative; Notice of Filing Take notice that on October 1, 2012, Southern Illinois Power Cooperative filed its Revised and Superseding Proposed Revenue Requirement for reactive supply service under...
77 FR 61596 - American Municipal Power, Inc.; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-10
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL13-1-000] American Municipal Power, Inc.; Notice of Filing Take notice that on October 1, 2012, American Municipal Power, Inc. filed its Revised and Superseding Proposed Revenue Requirement for reactive supply service under Midwest...
77 FR 61595 - Kentucky Municipal Power Agency; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-10
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL13-3-000] Kentucky Municipal Power Agency; Notice of Filing Take notice that on October 1, 2012, Kentucky Municipal Power Agency filed its Revised and Superseding Proposed Revenue Requirement for reactive supply service under...
77 FR 61594 - Prairie Power, Inc.; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-10
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL13-8-000] Prairie Power, Inc.; Notice of Filing Take notice that on October 1, 2012, Prairie Power, Inc. filed its Revised and Superseding Proposed Revenue Requirement for reactive supply service under Midwest Independent Transmission...
77 FR 47061 - Prairie Power, Inc.; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-07
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL12-90-000] Prairie Power, Inc.; Notice of Filing Take notice that on July 30, 2012, Prairie Power, Inc. filed a Proposed Revenue Requirement for reactive supply service under Midwest Independent Transmission System Operator, Inc. Tariff...
77 FR 47061 - American Municipal Power, Inc.; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-07
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL12-91-000] American Municipal Power, Inc.; Notice of Filing Take notice that on July 30, 2012, American Municipal Power, Inc. filed a Proposed Revenue Requirement for reactive supply service under Midwest Independent Transmission...
77 FR 61595 - Northern Illinois Municipal Power; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-10
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL13-5-000] Northern Illinois Municipal Power; Notice of Filing October 2, 2012. Take notice that on October 1, 2012, Northern Illinois Municipal Power filed its Revised and Superseding Proposed Revenue Requirement for reactive supply...
77 FR 61594 - Indiana Municipal Power Agency; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-10
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL13-7-000] Indiana Municipal Power Agency; Notice of Filing Take notice that on October 1, 2012, Indiana Municipal Power Agency filed its Revised and Superseding Proposed Revenue Requirement for reactive supply service under Midwest...
Application of a movable active vibration control system on a floating raft
NASA Astrophysics Data System (ADS)
Wang, Zhen; Mak, Cheuk Ming
2018-02-01
This paper presents a theoretical study of an inertial actuator connected to an accelerometer by a local feedback loop for active vibration control on a floating raft. On the criterion of the minimum power transmission from the vibratory machines to the flexible foundation in the floating raft, the best mounting positions for the inertial actuator on the intermediate mass of the floating raft are investigated. Simulation results indicate that the best mounting positions for the inertial actuator vary with frequency. To control time-varying excitations of vibratory machines on a floating raft effectively, an automatic control system based on real-time measurement of a cost function and automatically searching the best mounting position of the inertial actuator is proposed. To the best of our knowledge, it is the first time that an automatic control system is proposed to move an actuator automatically for controlling a time-varying excitation.
Automatic Thermal Infrared Panoramic Imaging Sensor
2006-11-01
hibernation, in which power supply to the server computer , the wireless network hardware, the GPS receiver, and the electronic compass / tilt sensor...prototype. At the operator’s command on the client laptop, the receiver wakeup device on the server side will switch on the ATX power supply at the...server, to resume the power supply to all the APTIS components. The embedded computer will resume all of the functions it was performing when put
Intermediate Fidelity Closed Brayton Cycle Power Conversion Model
NASA Technical Reports Server (NTRS)
Lavelle, Thomas M.; Khandelwal, Suresh; Owen, Albert K.
2006-01-01
This paper describes the implementation of an intermediate fidelity model of a closed Brayton Cycle power conversion system (Closed Cycle System Simulation). The simulation is developed within the Numerical Propulsion Simulation System architecture using component elements from earlier models. Of particular interest, and power, is the ability of this new simulation system to initiate a more detailed analysis of compressor and turbine components automatically and to incorporate the overall results into the general system simulation.
Proposals for the implementation of the variants of automatic control of the telescope AZT-2
NASA Astrophysics Data System (ADS)
Shavlovskyi, V. I.; Puha, S. P.; Vidmachenko, A. P.; Volovyk, D. V.; Puha, G. P.; Obolonskyi, V. O.; Kratko, O. O.; Stefurak, M. V.
2018-05-01
Based on the experience of astronomical observations, structural features and results of the review of the technical state of the mechanism of the telescope AZT-2 in the Main Astronomical Observatory of NAS of Ukraine, in 2012 it was decided to carry out works on its modernization. To this end, it was suggested that the telescope control system should consist of angle sensors on the time axis "alpha" and the axis "delta", personal computer (PC), corresponding software, power control unit, and rotation system of telescope. The angle sensor should be absolute, with a resolution of better than 10 angular minutes. The PC should perform the functions of data processing from the angle sensor, and control the power node. The developed software allows the operator to direct the telescope in an automatic mode, and to set the necessary parameters of the system. With using of PC, the power control node will directly control the engine of the rotation system.
Analysis of automatic repeat request methods for deep-space downlinks
NASA Technical Reports Server (NTRS)
Pollara, F.; Ekroot, L.
1995-01-01
Automatic repeat request (ARQ) methods cannot increase the capacity of a memoryless channel. However, they can be used to decrease the complexity of the channel-coding system to achieve essentially error-free transmission and to reduce link margins when the channel characteristics are poorly predictable. This article considers ARQ methods on a power-limited channel (e.g., the deep-space channel), where it is important to minimize the total power needed to transmit the data, as opposed to a bandwidth-limited channel (e.g., terrestrial data links), where the spectral efficiency or the total required transmission time is the most relevant performance measure. In the analysis, we compare the performance of three reference concatenated coded systems used in actual deep-space missions to that obtainable by ARQ methods using the same codes, in terms of required power, time to transmit with a given number of retransmissions, and achievable probability of word error. The ultimate limits of ARQ with an arbitrary number of retransmissions are also derived.
Automatic control of the preload in adaptive friction drives of chemical production machines
NASA Astrophysics Data System (ADS)
Balakin, P. D.
2017-08-01
Being based on the principle of providing the systems with adaptation property to the real parameters and operational condition, the energy effective mechanical system constructed on the base of friction gear with automated preload is offered and this allows keeping mechanical efficiency value adequate transforming drive path to in the terms of multimode operation. This is achieved by integrated control loop, operating on the basis of the laws of motion with the energy of the main power flow by changing automatically the kinematic dimension of the section and, hence, the value of preload in the friction contact. The given ratios of forces and deformations in the control loop are required at the stage of conceptual design to determine design dimensions of power transmission elements with new properties.
Design and implementation of a simple acousto optic dual control circuit
NASA Astrophysics Data System (ADS)
Li, Biqing; Li, Zhao
2017-04-01
This page proposed a simple light control circuit which designed by using power supply circuit, sonic circuits, electric circuit and delay circuit four parts. The main chip for CD4011, have inside of the four and to complete the sonic or circuit, electric, delay logic circuit. During the day, no matter how much a pedestrian voice, is ever shine light bulb. Dark night, circuit in a body to make the microphone as long as testing noise, and will automatically be bright for pedestrians lighting, several minutes after the automatic and put out, effective energy saving. Applicable scope and the working principle of the circuit principle diagram and given device parameters selection, power saving effect is obvious, at the same time greatly reduce the maintenance quantity, saving money, use effect is good.
Design of an anti-Rician-fading modem for mobile satellite communication systems
NASA Technical Reports Server (NTRS)
Kojima, Toshiharu; Ishizu, Fumio; Miyake, Makoto; Murakami, Keishi; Fujino, Tadashi
1995-01-01
To design a demodulator applicable to mobile satellite communication systems using differential phase shift keying modulation, we have developed key technologies including an anti-Rician-fading demodulation scheme, an initial acquisition scheme, automatic gain control (AGC), automatic frequency control (AFC), and bit timing recovery (BTR). Using these technologies, we have developed one-chip digital signal processor (DSP) modem for mobile terminal, which is compact, of light weight, and of low power consumption. Results of performance test show that the developed DSP modem achieves good performance in terms of bit error ratio in mobile satellite communication environment, i.e., Rician fading channel. It is also shown that the initial acquisition scheme acquires received signal rapidly even if the carrier-to-noise power ratio (CNR) of the received signal is considerably low.
Automatically activated, 300 ampere-hour silver-zinc cell
NASA Technical Reports Server (NTRS)
Hennigan, T. J.
1972-01-01
A prototype silver zinc cell is reported for which the electrolyte is being stored in a separate tank; the cell is being activated when additional power is required by collapsing the neoprene bellows container and thus forcing the electrolyte into cell through a plastic connection. A solar array is proposed as main power source for the flow actuator.
Automotive Power Flow System; Auto Mechanics I: 9043.04.
ERIC Educational Resources Information Center
Dade County Public Schools, Miami, FL.
This automotive power flow system course sets the foundation in the theory of operation of the standard and automatic transmission, clutch assemblies, drive-line and rear axle assemblies. This is a one or two quinmester credit course covering 45 clock hours. In the fourth quinmester course in the tenth year, instruction consists of lectures,…
49 CFR Appendix A to Part 222 - Approved Supplementary Safety Measures
Code of Federal Regulations, 2010 CFR
2010-10-01
... crossings located within New Partial Quiet Zones shall be closed from 10 p.m. until 7 a.m. every day. Public... apply only to New Quiet Zones or New Partial Quiet Zones. Constant warning time devices and power-out...-Rule Partial Quiet Zones are renewed, or new automatic warning device systems are installed, power-out...
78 FR 34370 - East Kentucky Power Cooperative, Inc.; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-07
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket Nos. EL13-68-000] East Kentucky Power Cooperative, Inc.; Notice of Filing Take notice that on May 30, 2013, East Kentucky Power Cooperative, Inc. filed its proposed revenue requirements for reactive supply and voltage control from...
78 FR 78347 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-26
..., 2013 Triennial Market Power Analysis of SGOC Southwest MBR Sellers for the Southwest Region. Filed Date... Numbers: ER14-630-000. Applicants: AlphaGen Power LLC. Description: Market-based rate application to be... Notice of succession-- Reactive Power Tariff to be effective 3/1/2014. Filed Date: 12/16/13. Accession...
76 FR 21722 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-18
... Notice of Cancellation of Reactive Power Rate Schedule. Filed Date: 04/07/2011. Accession Number...)(2)(iii): Revisions to the Tariff and OA re Emerg. Load Response Program ``Reporting'' to be... Reactive Rate Schedule Notice of Succession to be effective 3/9/2011. Filed Date: 04/07/2011. Accession...
Remediation of Explosives Contaminated Groundwater With Zero-Valent Iron
2011-10-01
1947. Howson, P.E., Mackenzie, P.D. and Horney, D.P., 1996. Enhanced reactive metal wall for dehalogenation of hydrocarbons. Tertiary Enhanced...reactive metal wall for dehalogenation of hydrocarbons, United States. Hundal, L.S., Singh, J., Bier, E.L., Shea, P.J., Comfort, S.D. and Power, W.L
76 FR 72203 - Voltage Coordination on High Voltage Grids; Notice of Reliability Workshop Agenda
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-22
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. AD12-5-000] Voltage... currently coordinate the dispatch of reactive resources to support forecasted loads, generation and... reactive power needs of the distribution system or loads are coordinated or optimized. Panelists: Khaled...
NASA Astrophysics Data System (ADS)
Peter, Tilo; Polonskyi, Oleksandr; Gojdka, Björn; Mohammad Ahadi, Amir; Strunskus, Thomas; Zaporojtchenko, Vladimir; Biederman, Hynek; Faupel, Franz
2012-12-01
We quantitatively assessed the influence of reactive gases on the formation processes of transition metal clusters in a gas aggregation cluster source. A cluster source based on a 2 in. magnetron is used to study the production rate of titanium and cobalt clusters. Argon served as working gas for the DC magnetron discharge, and a small amount of reactive gas (oxygen and nitrogen) is added to promote reactive cluster formation. We found that the cluster production rate depends strongly on the reactive gas concentration for very small amounts of reactive gas (less than 0.1% of total working gas), and no cluster formation takes place in the absence of reactive species. The influence of discharge power, reactive gas concentration, and working gas pressure are investigated using a quartz micro balance in a time resolved manner. The strong influence of reactive gas is explained by a more efficient formation of nucleation seeds for metal-oxide or nitride than for pure metal.
Thin, nearly wireless adaptive optical device
NASA Technical Reports Server (NTRS)
Knowles, Gareth (Inventor); Hughes, Eli (Inventor)
2008-01-01
A thin, nearly wireless adaptive optical device capable of dynamically modulating the shape of a mirror in real time to compensate for atmospheric distortions and/or variations along an optical material is provided. The device includes an optical layer, a substrate, at least one electronic circuit layer with nearly wireless architecture, an array of actuators, power electronic switches, a reactive force element, and a digital controller. Actuators are aligned so that each axis of expansion and contraction intersects both substrate and reactive force element. Electronics layer with nearly wireless architecture, power electronic switches, and digital controller are provided within a thin-film substrate. The size and weight of the adaptive optical device is solely dominated by the size of the actuator elements rather than by the power distribution system.
Thin, nearly wireless adaptive optical device
NASA Technical Reports Server (NTRS)
Knowles, Gareth (Inventor); Hughes, Eli (Inventor)
2007-01-01
A thin, nearly wireless adaptive optical device capable of dynamically modulating the shape of a mirror in real time to compensate for atmospheric distortions and/or variations along an optical material is provided. The device includes an optical layer, a substrate, at least one electronic circuit layer with nearly wireless architecture, an array of actuators, power electronic switches, a reactive force element, and a digital controller. Actuators are aligned so that each axis of expansion and contraction intersects both substrate and reactive force element. Electronics layer with nearly wireless architecture, power electronic switches, and digital controller are provided within a thin-film substrate. The size and weight of the adaptive optical device is solely dominated by the size of the actuator elements rather than by the power distribution system.
Thin nearly wireless adaptive optical device
NASA Technical Reports Server (NTRS)
Knowles, Gareth J. (Inventor); Hughes, Eli (Inventor)
2009-01-01
A thin nearly wireless adaptive optical device capable of dynamically modulating the shape of a mirror in real time to compensate for atmospheric distortions and/or variations along an optical material is provided. The device includes an optical layer, a substrate, at least one electronic circuit layer with nearly wireless architecture, an array of actuators, power electronic switches, a reactive force element, and a digital controller. Actuators are aligned so that each axis of expansion and contraction intersects both substrate and reactive force element. Electronics layer with nearly wireless architecture, power electronic switches, and digital controller are provided within a thin-film substrate. The size and weight of the adaptive optical device is solely dominated by the size of the actuator elements rather than by the power distribution system.
Master/Programmable-Slave Computer
NASA Technical Reports Server (NTRS)
Smaistrla, David; Hall, William A.
1990-01-01
Unique modular computer features compactness, low power, mass storage of data, multiprocessing, and choice of various input/output modes. Master processor communicates with user via usual keyboard and video display terminal. Coordinates operations of as many as 24 slave processors, each dedicated to different experiment. Each slave circuit card includes slave microprocessor and assortment of input/output circuits for communication with external equipment, with master processor, and with other slave processors. Adaptable to industrial process control with selectable degrees of automatic control, automatic and/or manual monitoring, and manual intervention.
Wheelchair ergometer. Development of a prototype with electronic braking.
Forchheimer, F; Lundberg, A
1986-01-01
A new wheelchair ergometer is described, which compensates for the pulsating character of the work by an automatic control system. This makes it possible to maintain a constant level of power during wheelchair work. An automatic control system has been integrated in an electronically braked bicycle ergometer, and a pedal unit from Rodby Electronic bicycle ergometer RE 820 has been coupled to a modified test wheelchair. With this device, the physical working capacity during submaximal circumstances can be tested in handicapped persons.
NASA Technical Reports Server (NTRS)
Feinreich, B.; Gevaert, G.
1980-01-01
Automatic flare and decrab control laws for conventional takeoff and landing aircraft were adapted to the unique requirements of the powered lift short takeoff and landing airplane. Three longitudinal autoland control laws were developed. Direct lift and direct drag control were used in the longitudinal axis. A fast time simulation was used for the control law synthesis, with emphasis on stochastic performance prediction and evaluation. Good correlation with flight test results was obtained.
NASA Technical Reports Server (NTRS)
Tinling, B. E.
1977-01-01
Estimates of the effectiveness of a model following type control system in reducing the roll excursion due to a wake vortex encounter were obtained from single degree of freedom computations with inputs derived from the results of wind tunnel, flight, and simulation experiments. The analysis indicates that the control power commanded by the automatic system must be roughly equal to the vortex induced roll acceleration if effective limiting of the maximum bank angle is to be achieved.
NASA Astrophysics Data System (ADS)
Durocher, M.; Mostofi Zadeh, S.; Burn, D. H.; Ashkar, F.
2017-12-01
Floods are one of the most costly hazards and frequency analysis of river discharges is an important part of the tools at our disposal to evaluate their inherent risks and to provide an adequate response. In comparison to the common examination of annual streamflow maximums, peaks over threshold (POT) is an interesting alternative that makes better use of the available information by including more than one flood event per year (on average). However, a major challenge is the selection of a satisfactory threshold above which peaks are assumed to respect certain conditions necessary for an adequate estimation of the risk. Additionally, studies have shown that POT is also a valuable approach to investigate the evolution of flood regimes in the context of climate change. Recently, automatic procedures for the selection of the threshold were suggested to guide that important choice, which otherwise rely on graphical tools and expert judgment. Furthermore, having an automatic procedure that is objective allows for quickly repeating the analysis on a large number of samples, which is useful in the context of large databases or for uncertainty analysis based on a resampling approach. This study investigates the impact of considering such procedures in a case study including many sites across Canada. A simulation study is conducted to evaluate the bias and predictive power of the automatic procedures in similar conditions as well as investigating the power of derived nonstationarity tests. The results obtained are also evaluated in the light of expert judgments established in a previous study. Ultimately, this study provides a thorough examination of the considerations that need to be addressed when conducting POT analysis using automatic threshold selection.
Observations of Earth space by self-powered stations in Antarctica.
Mende, S B; Rachelson, W; Sterling, R; Frey, H U; Harris, S E; McBride, S; Rosenberg, T J; Detrick, D; Doolittle, J L; Engebretson, M; Inan, U; Labelle, J W; Lanzerotti, L J; Weatherwax, A T
2009-12-01
Coupling of the solar wind to the Earth magnetosphere/ionosphere is primarily through the high latitude regions, and there are distinct advantages in making remote sensing observations of these regions with a network of ground-based observatories over other techniques. The Antarctic continent is ideally situated for such a network, especially for optical studies, because the larger offset between geographic and geomagnetic poles in the south enables optical observations at a larger range of magnetic latitudes during the winter darkness. The greatest challenge for such ground-based observations is the generation of power and heat for a sizable ground station that can accommodate an optical imaging instrument. Under the sponsorship of the National Science Foundation, we have developed suitable automatic observing platforms, the Automatic Geophysical Observatories (AGOs) for a network of six autonomous stations on the Antarctic plateau. Each station housed a suite of science instruments including a dual wavelength intensified all-sky camera that records the auroral activity, an imaging riometer, fluxgate and search-coil magnetometers, and ELF/VLF and LM/MF/HF receivers. Originally these stations were powered by propane fuelled thermoelectric generators with the fuel delivered to the site each Antarctic summer. A by-product of this power generation was a large amount of useful heat, which was applied to maintain the operating temperature of the electronics in the stations. Although a reasonable degree of reliability was achieved with these stations, the high cost of the fuel air lift and some remaining technical issues necessitated the development of a different type of power unit. In the second phase of the project we have developed a power generation system using renewable energy that can operate automatically in the Antarctic winter. The most reliable power system consists of a type of wind turbine using a simple permanent magnet rotor and a new type of power control system with variable resistor shunts to regulate the power and dissipate the excess energy and at the same time provide heat for a temperature controlled environment for the instrument electronics and data system. We deployed such systems and demonstrated a high degree of reliability in several years of operation in spite of the relative unpredictability of the Antarctic environment. Sample data are shown to demonstrate that the AGOs provide key measurements, which would be impossible without the special technology developed for this type of observing platform.
Observations of Earth space by self-powered stations in Antarctica
NASA Astrophysics Data System (ADS)
Mende, S. B.; Rachelson, W.; Sterling, R.; Frey, H. U.; Harris, S. E.; McBride, S.; Rosenberg, T. J.; Detrick, D.; Doolittle, J. L.; Engebretson, M.; Inan, U.; Labelle, J. W.; Lanzerotti, L. J.; Weatherwax, A. T.
2009-12-01
Coupling of the solar wind to the Earth magnetosphere/ionosphere is primarily through the high latitude regions, and there are distinct advantages in making remote sensing observations of these regions with a network of ground-based observatories over other techniques. The Antarctic continent is ideally situated for such a network, especially for optical studies, because the larger offset between geographic and geomagnetic poles in the south enables optical observations at a larger range of magnetic latitudes during the winter darkness. The greatest challenge for such ground-based observations is the generation of power and heat for a sizable ground station that can accommodate an optical imaging instrument. Under the sponsorship of the National Science Foundation, we have developed suitable automatic observing platforms, the Automatic Geophysical Observatories (AGOs) for a network of six autonomous stations on the Antarctic plateau. Each station housed a suite of science instruments including a dual wavelength intensified all-sky camera that records the auroral activity, an imaging riometer, fluxgate and search-coil magnetometers, and ELF/VLF and LM/MF/HF receivers. Originally these stations were powered by propane fuelled thermoelectric generators with the fuel delivered to the site each Antarctic summer. A by-product of this power generation was a large amount of useful heat, which was applied to maintain the operating temperature of the electronics in the stations. Although a reasonable degree of reliability was achieved with these stations, the high cost of the fuel air lift and some remaining technical issues necessitated the development of a different type of power unit. In the second phase of the project we have developed a power generation system using renewable energy that can operate automatically in the Antarctic winter. The most reliable power system consists of a type of wind turbine using a simple permanent magnet rotor and a new type of power control system with variable resistor shunts to regulate the power and dissipate the excess energy and at the same time provide heat for a temperature controlled environment for the instrument electronics and data system. We deployed such systems and demonstrated a high degree of reliability in several years of operation in spite of the relative unpredictability of the Antarctic environment. Sample data are shown to demonstrate that the AGOs provide key measurements, which would be impossible without the special technology developed for this type of observing platform.
Enhancing the potential of enantioselective organocatalysis with light
NASA Astrophysics Data System (ADS)
Silvi, Mattia; Melchiorre, Paolo
2018-02-01
Organocatalysis—catalysis mediated by small chiral organic molecules—is a powerful technology for enantioselective synthesis, and has extensive applications in traditional ionic, two-electron-pair reactivity domains. Recently, organocatalysis has been successfully combined with photochemical reactivity to unlock previously inaccessible reaction pathways, thereby creating new synthetic opportunities. Here we describe the historical context, scientific reasoning and landmark discoveries that were essential in expanding the functions of organocatalysis to include one-electron-mediated chemistry and excited-state reactivity.
Impact of Reactor Operating Parameters on Cask Reactivity in BWR Burnup Credit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ilas, Germina; Betzler, Benjamin R; Ade, Brian J
This paper discusses the effect of reactor operating parameters used in fuel depletion calculations on spent fuel cask reactivity, with relevance for boiling-water reactor (BWR) burnup credit (BUC) applications. Assessments that used generic BWR fuel assembly and spent fuel cask configurations are presented. The considered operating parameters, which were independently varied in the depletion simulations for the assembly, included fuel temperature, bypass water density, specific power, and operating history. Different operating history scenarios were considered for the assembly depletion to determine the effect of relative power distribution during the irradiation cycles, as well as the downtime between cycles. Depletion, decay,more » and criticality simulations were performed using computer codes and associated nuclear data within the SCALE code system. Results quantifying the dependence of cask reactivity on the assembly depletion parameters are presented herein.« less
NASA Technical Reports Server (NTRS)
Bragg-Sitton, Shannon M.; Hervol, David S.; Godfroy, Thomas J.
2009-01-01
A Direct Drive Gas-Cooled (DDG) reactor core simulator has been coupled to a Brayton Power Conversion Unit (BPCU) for integrated system testing at NASA Glenn Research Center (GRC) in Cleveland, OH. This is a closed-cycle system that incorporates an electrically heated reactor core module, turbo alternator, recuperator, and gas cooler. Nuclear fuel elements in the gas-cooled reactor design are replaced with electric resistance heaters to simulate the heat from nuclear fuel in the corresponding fast spectrum nuclear reactor. The thermodynamic transient behavior of the integrated system was the focus of this test series. In order to better mimic the integrated response of the nuclear-fueled system, a simulated reactivity feedback control loop was implemented. Core power was controlled by a point kinetics model in which the reactivity feedback was based on core temperature measurements; the neutron generation time and the temperature feedback coefficient are provided as model inputs. These dynamic system response tests demonstrate the overall capability of a non-nuclear test facility in assessing system integration issues and characterizing integrated system response times and response characteristics.
NASA Technical Reports Server (NTRS)
Bragg-Sitton, Shannon M.; Hervol, David S.; Godfroy, Thomas J.
2010-01-01
A Direct Drive Gas-Cooled (DDG) reactor core simulator has been coupled to a Brayton Power Conversion Unit (BPCU) for integrated system testing at NASA Glenn Research Center (GRC) in Cleveland, Ohio. This is a closed-cycle system that incorporates an electrically heated reactor core module, turboalternator, recuperator, and gas cooler. Nuclear fuel elements in the gas-cooled reactor design are replaced with electric resistance heaters to simulate the heat from nuclear fuel in the corresponding fast spectrum nuclear reactor. The thermodynamic transient behavior of the integrated system was the focus of this test series. In order to better mimic the integrated response of the nuclear-fueled system, a simulated reactivity feedback control loop was implemented. Core power was controlled by a point kinetics model in which the reactivity feedback was based on core temperature measurements; the neutron generation time and the temperature feedback coefficient are provided as model inputs. These dynamic system response tests demonstrate the overall capability of a non-nuclear test facility in assessing system integration issues and characterizing integrated system response times and response characteristics.
Code of Federal Regulations, 2011 CFR
2011-01-01
... gear retraction may not be begun until the airplane is airborne. (c) During the takeoff path... changed, except for gear retraction and automatic propeller feathering, and no change in power or thrust...
Code of Federal Regulations, 2014 CFR
2014-01-01
... gear retraction may not be begun until the airplane is airborne. (c) During the takeoff path... changed, except for gear retraction and automatic propeller feathering, and no change in power or thrust...
Code of Federal Regulations, 2010 CFR
2010-01-01
... gear retraction may not be begun until the airplane is airborne. (c) During the takeoff path... changed, except for gear retraction and automatic propeller feathering, and no change in power or thrust...
Code of Federal Regulations, 2012 CFR
2012-01-01
... gear retraction may not be begun until the airplane is airborne. (c) During the takeoff path... changed, except for gear retraction and automatic propeller feathering, and no change in power or thrust...
Code of Federal Regulations, 2013 CFR
2013-01-01
... gear retraction may not be begun until the airplane is airborne. (c) During the takeoff path... changed, except for gear retraction and automatic propeller feathering, and no change in power or thrust...
Development of Automatic Controller of Brain Temperature Based on the Conditions of Clinical Use
NASA Astrophysics Data System (ADS)
Utsuki, Tomohiko; Wakamatsu, Hidetoshi
A new automatic controller of brain temperature was developed based on the inevitable conditions of its clinical use from the viewpoint of various kinds of feasibility, in particular, electric power consumption of less than 1,500W in ICU. The adaptive algorithm was employed to cope with individual time-varying characteristic change of patients. The controller under water-surface cooling hypothermia requires much power for the frequent regulation of the water temperature of cooling blankets. Thus, in this study, the power consumption of the controller was checked by several kinds of examinations involving the control simulation of brain temperature using a mannequin with thermal characteristics similar to that of adult patients. The required accuracy of therapeutic brain hypothermia, i.e. control deviation within ±0.1C was experimentally confirmed using “root mean square of the control error”, despite the present controller consumes less energy comparing with the one in the case of our conventional controller, where it can still keeps remaining power margin more than 300W even in the full operation. Thereby, the clinically required water temperature was also confirmed within the limit of power supply, thus its practical application is highly expected with less physical burden of medical staff inclusive of more usability and more medical cost performance.
Arc lamp power supply using a voltage multiplier
NASA Technical Reports Server (NTRS)
Leighty, Bradley D.
1988-01-01
A power supply is provided for an arc discharge lamp which includes a relatively low voltage high current power supply section and a high voltage starter circuit. The low voltage section includes a transformer, rectifier, variable resistor and a bank of capacitors, while the starter circuit comprises several diodes and capacitors connected as a Cockcroft-Walton multiplier. The starting circuit is effectively bypassed when the lamp arc is established and serves to automatically provide a high starting voltage to re-strike the lamp arc if the arc is extinguished by a power interruption.
Igual, Laura; Soliva, Joan Carles; Escalera, Sergio; Gimeno, Roger; Vilarroya, Oscar; Radeva, Petia
2012-12-01
We present a fully automatic diagnostic imaging test for Attention-Deficit/Hyperactivity Disorder diagnosis assistance based on previously found evidences of caudate nucleus volumetric abnormalities. The proposed method consists of different steps: a new automatic method for external and internal segmentation of caudate based on Machine Learning methodologies; the definition of a set of new volume relation features, 3D Dissociated Dipoles, used for caudate representation and classification. We separately validate the contributions using real data from a pediatric population and show precise internal caudate segmentation and discrimination power of the diagnostic test, showing significant performance improvements in comparison to other state-of-the-art methods. Copyright © 2012 Elsevier Ltd. All rights reserved.
The charging security study of electric vehicle charging spot based on automatic testing platform
NASA Astrophysics Data System (ADS)
Li, Yulan; Yang, Zhangli; Zhu, Bin; Ran, Shengyi
2018-03-01
With the increasing of charging spots, the testing of charging security and interoperability becomes more and more urgent and important. In this paper, an interface simulator for ac charging test is designed, the automatic testing platform for electric vehicle charging spots is set up and used to test and analyze the abnormal state during the charging process. On the platform, the charging security and interoperability of ac charging spots and IC-CPD can be checked efficiently, the test report can be generated automatically with No artificial reading error. From the test results, the main reason why the charging spot is not qualified is that the power supply cannot be cut off in the prescribed time when the charging anomaly occurs.
Feedback circuit design of an auto-gating power supply for low-light-level image intensifier
NASA Astrophysics Data System (ADS)
Yang, Ye; Yan, Bo; Zhi, Qiang; Ni, Xiao-bing; Li, Jun-guo; Wang, Yu; Yao, Ze
2015-11-01
This paper introduces the basic principle of auto-gating power supply which using a hybrid automatic brightness control scheme. By the analysis of current as image intensifier to special requirements of auto-gating power supply, a feedback circuit of the auto-gating power supply is analyzed. Find out the reason of the screen flash after the auto-gating power supply assembled image intensifier. This paper designed a feedback circuit which can shorten the response time of auto-gating power supply and improve screen slight flicker phenomenon which the human eye can distinguish under the high intensity of illumination.
Preparation of TiN films by reactive high-power pulsed sputtering Penning discharges
NASA Astrophysics Data System (ADS)
Kimura, Takashi; Yoshida, Ryo; Mishima, Toshihiko; Azuma, Kingo; Nakao, Setsuo
2018-06-01
Titanium nitride (TiN) films are prepared by reactive high-power pulsed sputtering Penning discharges at a total pressure of 0.7 Pa and an average power of 60 W, where the nitrogen fraction is varied up to 15%. The peak value of the instantaneous power ranges between 3 and 14 kW, and the peak power density ranges between 0.3 and 1.2 kW cm‑2. The hardness of TiN films is higher than 22 GPa at the nitrogen fractions lower than 10% and it reaches 31 GPa at a nitrogen fraction of 5%. The X-ray diffraction peak of TiN(111) texture is observed for all prepared films, showing the grain size of about 10 nm. In X-ray photoelectron spectroscopy, oxygen is mainly bonded to titanium, but the intensity of the TiN bond is dominant in the entire Ti 2p spectrum. The intensity ratio of N 1s to Ti 2p ranges between 0.85 and 0.95.