Development of testing and training simulator for CEDMCS in KSNP
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nam, C. H.; Park, C. Y.; Nam, J. I.
2006-07-01
This paper presents a newly developed testing and training simulator (TTS) for automatically diagnosing and tuning the Control Element Drive Mechanism Control System (CEDMCS). TTS includes a new automatic, diagnostic, method for logic control cards and a new tuning method for phase synchronous pulse cards. In Korea Standard Nuclear Power Plants (KSNP). reactor trips occasionally occur due to a damaged logic control card in CEDMCS. However, there is no pre-diagnostic tester available to detect a damaged card in CEDMCS before it causes a reactor trip. Even after the reactor trip occurs, it is difficult to find the damaged card. Tomore » find the damaged card. ICT is usually used. ICT is an automated, computer-controlled testing system with measurement capabilities for testing active and passive components, or clusters of components, on printed circuit boards (PCB) and/or assemblies. However, ICT cannot detect a time dependent fault correctly and requires removal of the waterproof mating to perform the test. Therefore, the additional procedure of re-coating the PCB card is required after the test. TTS for CEDMCS is designed based on real plant conditions, both electrically and mechanically. Therefore, the operator can operate the Control Element Drive Mechanism (CEDM), which is mounted on the closure head of the reactor vessel (RV) using the soft control panel in ITS, which duplicates the Main Control Board (MCB) in the Main Control Room (MCR). However, during the generation of electric power in a nuclear power plant, it is difficult to operate the CEDM so a CEDM and Control Element Assembly (CEA) mock-up facility was developed to simulate a real plant CEDM. ITS was used for diagnosing and tuning control logic cards in CEDMCS in the Ulchin Nuclear Power Plant No. 4 during the plant overhaul period. It exhibited good performance in detecting the damaged cards and tuning the phase synchronous pulse cards. In addition, TTS was useful in training the CEDMCS operator by supplying detail signal information from the logic cards. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, D.S.; Seong, P.H.
1995-08-01
In this paper, an improved algorithm for automatic test pattern generation (ATG) for nuclear power plant digital electronic circuits--the combinational type of logic circuits is presented. For accelerating and improving the ATG process for combinational circuits the presented ATG algorithm has the new concept--the degree of freedom (DF). The DF, directly computed from the system descriptions such as types of gates and their interconnections, is the criterion to decide which among several alternate lines` logic values required along each path promises to be the most effective in order to accelerate and improve the ATG process. Based on the DF themore » proposed ATG algorithm is implemented in the automatic fault diagnosis system (AFDS) which incorporates the advanced fault diagnosis method of artificial intelligence technique, it is shown that the AFDS using the ATG algorithm makes Universal Card (UV Card) testing much faster than the present testing practice or by using exhaustive testing sets.« less
Waveform stimulus subsystem: An advanced technology multifunction subsystem on a card
NASA Astrophysics Data System (ADS)
Pritchard, David J.
The F-15 TISS ATE (automatic test equipment) requires subsystem-on-a-card technology to achieve the required functionality within the space constraints. The waveform stimulus subsystem (WSS), an example of this advanced technology, is considered. The WSS circuit card consists of two 40-MHz pulse generators and an 80-MHz aribtrary waveform generator. Each generator is independently programmed and is available simultaneously to the user. The implementation of this highly integrated malfunction-detection system on a card is described, and the benefits to performance and maintainability are highlighted.
ERIC Educational Resources Information Center
Fisher, Anna V.
2011-01-01
Two experiments tested a hypothesis that reducing demands on executive control in a Dimensional Change Card Sort task will lead to improved performance in 3-year-olds. In Experiment 1, the shape dimension was represented by two dissimilar values ("stars" and "flowers"), and the color dimension was represented by two similar values ("red" and…
Design of efficient and simple interface testing equipment for opto-electric tracking system
NASA Astrophysics Data System (ADS)
Liu, Qiong; Deng, Chao; Tian, Jing; Mao, Yao
2016-10-01
Interface testing for opto-electric tracking system is one important work to assure system running performance, aiming to verify the design result of every electronic interface matching the communication protocols or not, by different levels. Opto-electric tracking system nowadays is more complicated, composed of many functional units. Usually, interface testing is executed between units manufactured completely, highly depending on unit design and manufacture progress as well as relative people. As a result, it always takes days or weeks, inefficiently. To solve the problem, this paper promotes an efficient and simple interface testing equipment for opto-electric tracking system, consisting of optional interface circuit card, processor and test program. The hardware cards provide matched hardware interface(s), easily offered from hardware engineer. Automatic code generation technique is imported, providing adaption to new communication protocols. Automatic acquiring items, automatic constructing code architecture and automatic encoding are used to form a new program quickly with adaption. After simple steps, a standard customized new interface testing equipment with matching test program and interface(s) is ready for a waiting-test system in minutes. The efficient and simple interface testing equipment for opto-electric tracking system has worked for many opto-electric tracking system to test entire or part interfaces, reducing test time from days to hours, greatly improving test efficiency, with high software quality and stability, without manual coding. Used as a common tool, the efficient and simple interface testing equipment for opto-electric tracking system promoted by this paper has changed traditional interface testing method and created much higher efficiency.
Type testing the Model 6600 plus automatic TLD reader.
Velbeck, K J; Luo, L Z; Streetz, K L
2006-01-01
The Harshaw Model 6600 Plus is a reader with a capacity for 200 TLD cards or 800 extremity cards. The new unit integrates more functionality, and significantly automates the QC and calibration process compared to the Model 6600. The Model 6600 Plus was tested against the IEC 61066 (1991-2012) procedures using Harshaw TLD-700H and TLD-600H, LiF:Mg,Cu,P based TLD Cards. An overview of the type testing procedures is presented. These include batch homogeneity, detection threshold, reproducibility, linearity, self-irradiation, residue, light effects on dosemeter, light leakage to reader, voltage and frequency, dropping and reader stability. The new TLD reader was found to meet all the IEC criteria by large margins and appears well suited for whole body, extremity and environmental dosimetry applications, with a high degree of dosimetric performance.
NASA Astrophysics Data System (ADS)
Wojenski, Andrzej; Kasprowicz, Grzegorz; Pozniak, Krzysztof T.; Romaniuk, Ryszard
2013-10-01
The paper describes a concept of automatic firmware generation for reconfigurable measurement systems, which uses FPGA devices and measurement cards in FMC standard. Following sections are described in details: automatic HDL code generation for FPGA devices, automatic communication interfaces implementation, HDL drivers for measurement cards, automatic serial connection between multiple measurement backplane boards, automatic build of memory map (address space), automatic generated firmware management. Presented solutions are required in many advanced measurement systems, like Beam Position Monitors or GEM detectors. This work is a part of a wider project for automatic firmware generation and management of reconfigurable systems. Solutions presented in this paper are based on previous publication in SPIE.
Diagnosis - Using automatic test equipment and artificial intelligence expert systems
NASA Astrophysics Data System (ADS)
Ramsey, J. E., Jr.
Three expert systems (ATEOPS, ATEFEXPERS, and ATEFATLAS), which were created to direct automatic test equipment (ATE), are reviewed. The purpose of the project was to develop an expert system to troubleshoot the converter-programmer power supply card for the F-15 aircraft and have that expert system direct the automatic test equipment. Each expert system uses a different knowledge base or inference engine, basing the testing on the circuit schematic, test requirements document, or ATLAS code. Implementing generalized modules allows the expert systems to be used for any different unit under test. Using converted ATLAS to LISP code allows the expert system to direct any ATE using ATLAS. The constraint propagated frame system allows for the expansion of control by creating the ATLAS code, checking the code for good software engineering techniques, directing the ATE, and changing the test sequence as needed (planning).
Remembering spatial locations: effects of material and intelligence.
Zucco, G M; Tessari, A; Soresi, S
1995-04-01
The aim of the present work was to test some of the criteria for automaticity of spatial-location coding claimed by Hasher and Zacks, particularly individual differences (as intelligence invariance) and effortful encoding strategies. Two groups of subjects, 15 with mental retardation (Down Syndrome, mean chronological age, 20.9 yr.; mean mental age, 11.6 yr.) and 15 normal children (mean age, 11.5 yr.), were administered four kinds of stimuli (pictures, concrete words, nonsense pictures, and abstract words) at one location on a card. Subsequently, subjects were presented the items on the card's centre and were required to place the items in their original locations. Analysis indicated that those with Down Syndrome scored lower than normal children on the four tasks and that stimuli were better or worse remembered according to their characteristics, e.g., their imaginability. Results do not support some of the conditions claimed to be necessary criteria for automaticity in the recall of spatial locations as stated by Hasher and Zacks.
Design of a real-time tax-data monitoring intelligent card system
NASA Astrophysics Data System (ADS)
Gu, Yajun; Bi, Guotang; Chen, Liwei; Wang, Zhiyuan
2009-07-01
To solve the current problem of low efficiency of domestic Oil Station's information management, Oil Station's realtime tax data monitoring system has been developed to automatically access tax data of Oil pumping machines, realizing Oil-pumping machines' real-time automatic data collection, displaying and saving. The monitoring system uses the noncontact intelligent card or network to directly collect data which can not be artificially modified and so seals the loopholes and improves the tax collection's automatic level. It can perform real-time collection and management of the Oil Station information, and find the problem promptly, achieves the automatic management for the entire process covering Oil sales accounting and reporting. It can also perform remote query to the Oil Station's operation data. This system has broad application future and economic value.
Post-Attack Economic Stabilization Issues for Federal, State, and Local Governments
1985-02-01
workers being transfered from large urban areas to production facilities in areas of lower risk . In another case, rent control staff should be quickly...food supermarkets , which do not universally accept bank cards. 3 0 A requirement will still exist for a large number of credit cards. While there is some...separate system is required for rationing. For example, the increasingly popular automatic teller machine ( ATM ) debit card routinely accesses both a
Reminder card helps patients remember OCs.
1999-11-01
Organon has developed the Reminder Card to help women patients remember their regular intake of oral contraceptive (OC) pills. About 50% of women take birth control pills as prescribed, 25% miss a pill per month, and 25% miss two or more pills in the same time frame. The plastic card, about the size and shape of a credit card, contains a microchip timer. Reminder cards are available to providers who use the Starter Kits issued by the company for new-start patients on the Mircette OC. When patients begin their first pack of pills, they select the time of day they prefer to have the Reminder Card emit its tiny beep. The time is set into the microchip timer and the card is programmed to sound automatically at the pre-set time each day for the next three months. The direction for using the Reminder Card is outlined.
ERIC Educational Resources Information Center
Harris, Julian; Maurer, Hermann
An investigation into high level event monitoring within the scope of a well-known multimedia application, HyperCard--a program on the Macintosh computer, is carried out. A monitoring system is defined as a system which automatically monitors usage of some activity and gathers statistics based on what is has observed. Monitor systems can give the…
6 CFR 37.19 - Machine readable technology on the driver's license or identification card.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., States must use the ISO/IEC 15438:2006(E) Information Technology—Automatic identification and data... 6 Domestic Security 1 2011-01-01 2011-01-01 false Machine readable technology on the driver's..., Verification, and Card Issuance Requirements § 37.19 Machine readable technology on the driver's license or...
6 CFR 37.19 - Machine readable technology on the driver's license or identification card.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., States must use the ISO/IEC 15438:2006(E) Information Technology—Automatic identification and data... 6 Domestic Security 1 2010-01-01 2010-01-01 false Machine readable technology on the driver's..., Verification, and Card Issuance Requirements § 37.19 Machine readable technology on the driver's license or...
NASA Shuttle Logistics Depot (NSLD) - The application of ATE
NASA Technical Reports Server (NTRS)
Simpkins, Lorenz G.; Jenkins, Henry C.; Mauceri, A. Jack
1990-01-01
The concept of the NASA Shuttle Logistics Depot (NSLD) developed for the Space Shuttle Orbiter Program is described. The function of the NSLD at Cape Canaveral is to perform the acceptance and diagnostic testing of the Shuttle's space-rated line-replaceable units and shop-replaceable units (SRUs). The NSLD includes a comprehensive electronic automatic test station, program development stations, and assorted manufacturing support equipment (including thermal and vibration test equipment, special test equipment, and a card SRU test system). The depot activities also include the establishment of the functions for manufacturing of mechanical parts, soldering, welding, painting, clean room operation, procurement, and subcontract management.
Development of on line automatic separation device for apple and sleeve
NASA Astrophysics Data System (ADS)
Xin, Dengke; Ning, Duo; Wang, Kangle; Han, Yuhang
2018-04-01
Based on STM32F407 single chip microcomputer as control core, automatic separation device of fruit sleeve is designed. This design consists of hardware and software. In hardware, it includes mechanical tooth separator and three degree of freedom manipulator, as well as industrial control computer, image data acquisition card, end effector and other structures. The software system is based on Visual C++ development environment, to achieve localization and recognition of fruit sleeve with the technology of image processing and machine vision, drive manipulator of foam net sets of capture, transfer, the designated position task. Test shows: The automatic separation device of the fruit sleeve has the advantages of quick response speed and high separation success rate, and can realize separation of the apple and plastic foam sleeve, and lays the foundation for further studying and realizing the application of the enterprise production line.
[Integrated Development of Full-automatic Fluorescence Analyzer].
Zhang, Mei; Lin, Zhibo; Yuan, Peng; Yao, Zhifeng; Hu, Yueming
2015-10-01
In view of the fact that medical inspection equipment sold in the domestic market is mainly imported from abroad and very expensive, we developed a full-automatic fluorescence analyzer in our center, presented in this paper. The present paper introduces the hardware architecture design of FPGA/DSP motion controlling card+PC+ STM32 embedded micro processing unit, software system based on C# multi thread, design and implementation of double-unit communication in detail. By simplifying the hardware structure, selecting hardware legitimately and adopting control system software to object-oriented technology, we have improved the precision and velocity of the control system significantly. Finally, the performance test showed that the control system could meet the needs of automated fluorescence analyzer on the functionality, performance and cost.
Protection method for an optical information carrier
NASA Astrophysics Data System (ADS)
Pitsyuga, Vitaly V.; Kolesnikov, Michael Y.; Kosyak, Igor V.
1997-02-01
Now information protection on personal carriers (for example, cards) from an unauthorized access (UA) is a very important problem in connection with wide introduction of proper automatic systems for information processing in different spheres of human activity. These are financial, medical and information services, an access to restricted units and so on. There is proposed to use physical parameters of the special coating part (so-called restricted zone) to information protection on optical carriers (laser cards). There is formed restricted zone on the surface of the recording coating of a laser card. The unique information about every laser card to creating a protective passport from UA is obtained by readout of defects parameters.
Ogden, Samantha J; Horton, Jeffrey K; Stubbs, Simon L; Tatnell, Peter J
2015-01-01
The 1.2 mm Electric Coring Tool (e-Core™) was developed to increase the throughput of FTA(™) sample collection cards used during forensic workflows and is similar to a 1.2 mm Harris manual micro-punch for sampling dried blood spots. Direct short tandem repeat (STR) DNA profiling was used to compare samples taken by the e-Core tool with those taken by the manual micro-punch. The performance of the e-Core device was evaluated using a commercially available PowerPlex™ 18D STR System. In addition, an analysis was performed that investigated the potential carryover of DNA via the e-Core punch from one FTA disc to another. This contamination study was carried out using Applied Biosystems AmpflSTR™ Identifiler™ Direct PCR Amplification kits. The e-Core instrument does not contaminate FTA discs when a cleaning punch is used following excision of discs containing samples and generates STR profiles that are comparable to those generated by the manual micro-punch. © 2014 American Academy of Forensic Sciences.
Colorimetric calibration of wound photography with off-the-shelf devices
NASA Astrophysics Data System (ADS)
Bala, Subhankar; Sirazitdinova, Ekaterina; Deserno, Thomas M.
2017-03-01
Digital cameras are often used in recent days for photographic documentation in medical sciences. However, color reproducibility of same objects suffers from different illuminations and lighting conditions. This variation in color representation is problematic when the images are used for segmentation and measurements based on color thresholds. In this paper, motivated by photographic follow-up of chronic wounds, we assess the impact of (i) gamma correction, (ii) white balancing, (iii) background unification, and (iv) reference card-based color correction. Automatic gamma correction and white balancing are applied to support the calibration procedure, where gamma correction is a nonlinear color transform. For unevenly illuminated images, non- uniform illumination correction is applied. In the last step, we apply colorimetric calibration using a reference color card of 24 patches with known colors. A lattice detection algorithm is used for locating the card. The least squares algorithm is applied for affine color calibration in the RGB model. We have tested the algorithm on images with seven different types of illumination: with and without flash using three different off-the-shelf cameras including smartphones. We analyzed the spread of resulting color value of selected color patch before and after applying the calibration. Additionally, we checked the individual contribution of different steps of the whole calibration process. Using all steps, we were able to achieve a maximum of 81% reduction in standard deviation of color patch values in resulting images comparing to the original images. That supports manual as well as automatic quantitative wound assessments with off-the-shelf devices.
Beraud, L; Gervasoni, K; Freydiere, A M; Descours, G; Ranc, A G; Vandenesch, F; Lina, G; Gaia, V; Jarraud, S
2015-09-01
The Sofia Legionella Fluorescence Immunoassay (FIA; Quidel) is a recently introduced rapid immunochromatographic diagnostic test for Legionnaires' disease using immunofluorescence technology designed to enhance its sensitivity. The aim of this study was to evaluate its performance for the detection of urinary antigens for Legionella pneumophila serogroup 1 in two National Reference Centers for Legionella. The sensitivity and specificity of the Sofia Legionella FIA test were determined in concentrated and nonconcentrated urine samples, before and after boiling, in comparison with the BinaxNOW® Legionella Urinary Antigen Card (UAC; Alere). Compared with BinaxNOW® Legionella UAC, the sensitivity of the Sofia Legionella test was slightly higher in nonconcentrated urine samples and was identical in concentrated urine samples. The specificity of the Sofia Legionella FIA test was highly reduced by the concentration of urine samples. In nonconcentrated samples, a lack of specificity was observed in 2.3 % of samples, all of them resolved by heat treatment. The Sofia Legionella FIA is a sensitive test for detecting Legionella urinary antigens with no previous urine concentration. However, all positive samples have to be re-tested after boiling to reach a high specificity. The reading is automatized on the Sofia analyzer, which can be connected to laboratory information systems, facilitating accurate and rapid reporting of results.
Automatic system for ionization chamber current measurements.
Brancaccio, Franco; Dias, Mauro S; Koskinas, Marina F
2004-12-01
The present work describes an automatic system developed for current integration measurements at the Laboratório de Metrologia Nuclear of Instituto de Pesquisas Energéticas e Nucleares. This system includes software (graphic user interface and control) and a module connected to a microcomputer, by means of a commercial data acquisition card. Measurements were performed in order to check the performance and for validating the proposed design.
Better service, greater efficiency : transit management for demand response systems
DOT National Transportation Integrated Search
1999-01-01
This brochure briefly describes different technologies which can enhance demand response transit systems. It covers automated scheduling and dispatching, mobile data terminals, electronic identification cards, automatic vehicle location, and geograph...
Zenitani, Satoko; Nishiuchi, Hiromu; Kiuchi, Takahiro
2010-04-01
The Smart-card-based Automatic Meal Record system for company cafeterias (AutoMealRecord system) was recently developed and used to monitor employee eating habits. The system could be a unique nutrition assessment tool for automatically monitoring the meal purchases of all employees, although it only focuses on company cafeterias and has never been validated. Before starting an interventional study, we tested the reliability of the data collected by the system using the data mining approach. The AutoMealRecord data were examined to determine if it could predict current obesity. All data used in this study (n = 899) were collected by a major electric company based in Tokyo, which has been operating the AutoMealRecord system for several years. We analyzed dietary patterns by principal component analysis using data from the system and extracted 5 major dietary patterns: healthy, traditional Japanese, Chinese, Japanese noodles, and pasta. The ability to predict current body mass index (BMI) with dietary preference was assessed with multiple linear regression analyses, and in the current study, BMI was positively correlated with male gender, preference for "Japanese noodles," mean energy intake, protein content, and frequency of body measurement at a body measurement booth in the cafeteria. There was a negative correlation with age, dietary fiber, and lunchtime cafeteria use (R(2) = 0.22). This regression model predicted "would-be obese" participants (BMI >or= 23) with 68.8% accuracy by leave-one-out cross validation. This shows that there was sufficient predictability of BMI based on data from the AutoMealRecord System. We conclude that the AutoMealRecord system is valuable for further consideration as a health care intervention tool. Copyright 2010 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Haak, Daniel; Doma, Aliaa; Gombert, Alexander; Deserno, Thomas M.
2016-03-01
Today, subject's medical data in controlled clinical trials is captured digitally in electronic case report forms (eCRFs). However, eCRFs only insufficiently support integration of subject's image data, although medical imaging is looming large in studies today. For bed-side image integration, we present a mobile application (App) that utilizes the smartphone-integrated camera. To ensure high image quality with this inexpensive consumer hardware, color reference cards are placed in the camera's field of view next to the lesion. The cards are used for automatic calibration of geometry, color, and contrast. In addition, a personalized code is read from the cards that allows subject identification. For data integration, the App is connected to an communication and image analysis server that also holds the code-study-subject relation. In a second system interconnection, web services are used to connect the smartphone with OpenClinica, an open-source, Food and Drug Administration (FDA)-approved electronic data capture (EDC) system in clinical trials. Once the photographs have been securely stored on the server, they are released automatically from the mobile device. The workflow of the system is demonstrated by an ongoing clinical trial, in which photographic documentation is frequently performed to measure the effect of wound incision management systems. All 205 images, which have been collected in the study so far, have been correctly identified and successfully integrated into the corresponding subject's eCRF. Using this system, manual steps for the study personnel are reduced, and, therefore, errors, latency and costs decreased. Our approach also increases data security and privacy.
NASA Astrophysics Data System (ADS)
Schröder, Henning; Brusberg, Lars; Pitwon, Richard; Whalley, Simon; Wang, Kai; Miller, Allen; Herbst, Christian; Weber, Daniel; Lang, Klaus-Dieter
2015-03-01
Optical interconnects for data transmission at board level offer increased energy efficiency, system density, and bandwidth scalability compared to purely copper driven systems. We present recent results on manufacturing of electrooptical printed circuit board (PCB) with integrated planar glass waveguides. The graded index multi-mode waveguides are patterned inside commercially available thin-glass panels by performing a specific ion-exchange process. The glass waveguide panel is embedded within the layer stack-up of a PCB using proven industrial processes. This paper describes the design, manufacture, assembly and characterization of the first electro-optical backplane demonstrator based on integrated planar glass waveguides. The electro-optical backplane in question is created by laminating the glass waveguide panel into a conventional multi-layer electronic printed circuit board stack-up. High precision ferrule mounts are automatically assembled, which will enable MT compliant connectors to be plugged accurately to the embedded waveguide interfaces on the glass panel edges. The demonstration platform comprises a standardized sub-rack chassis and five pluggable test cards each housing optical engines and pluggable optical connectors. The test cards support a variety of different data interfaces and can support data rates of up to 32 Gb/s per channel.
ADMAP (automatic data manipulation program)
NASA Technical Reports Server (NTRS)
Mann, F. I.
1971-01-01
Instructions are presented on the use of ADMAP, (automatic data manipulation program) an aerospace data manipulation computer program. The program was developed to aid in processing, reducing, plotting, and publishing electric propulsion trajectory data generated by the low thrust optimization program, HILTOP. The program has the option of generating SC4020 electric plots, and therefore requires the SC4020 routines to be available at excution time (even if not used). Several general routines are present, including a cubic spline interpolation routine, electric plotter dash line drawing routine, and single parameter and double parameter sorting routines. Many routines are tailored for the manipulation and plotting of electric propulsion data, including an automatic scale selection routine, an automatic curve labelling routine, and an automatic graph titling routine. Data are accepted from either punched cards or magnetic tape.
Sight-Word Practice in a Flash!
ERIC Educational Resources Information Center
Erwin, Robin W., Jr.
2016-01-01
For learners who need sight-word practice, including young students and struggling readers, digital flash cards may promote automatic word recognition when used as a supplemental activity to regular reading instruction. A novel use of common presentation software efficiently supports this practice strategy.
Ghinsberg, R; Meir, E; Blumstein, G; Kafeman, R
1975-11-01
The Rappaport rapid (RR) plate and card tests were developed as modifications of the RR tube test to permit rapid and inexpensive screening of large numbers of subjects for the diagnosis of syphilis. More than 2,000 sera were examined in parallel by the Venereal Disease Research Laboratory (VDRL) slide test, the rapid plasma reagin (RPR) card test and the RR plate and card tests. There was complete agreement between the RR plate and card tests and the VDRL slide and RPR card tests in 96.6% of sera. In a selected group of 1,530 sera examined, in addition, by the fluorescent treponemal antibody absorption (FTA-ABS) test, there was agreement between the RR plate and card tests and the FTA-ABS test in 74.3% of sera and between the VDRL and RPR tests and the FTA-ABS test in 73.7% of sera. The RR plate test was found to be sufficiently sensitive and specific for the diagnosis of syphilis, although the VDRL slide test is perhaps more sensitive in primary and late latent syphilis. Since the antigen used in the RR tests is colored and stable and the sera do not require inactivation before the test, the tests are easier to perform than the VDRL slide test: the RR plate and card tests could therefore replace the VDRL test as a screening test, with hardly any loss of accuracy.
Master/Programmable-Slave Computer
NASA Technical Reports Server (NTRS)
Smaistrla, David; Hall, William A.
1990-01-01
Unique modular computer features compactness, low power, mass storage of data, multiprocessing, and choice of various input/output modes. Master processor communicates with user via usual keyboard and video display terminal. Coordinates operations of as many as 24 slave processors, each dedicated to different experiment. Each slave circuit card includes slave microprocessor and assortment of input/output circuits for communication with external equipment, with master processor, and with other slave processors. Adaptable to industrial process control with selectable degrees of automatic control, automatic and/or manual monitoring, and manual intervention.
Test device for measuring permeability of a barrier material
Reese, Matthew; Dameron, Arrelaine; Kempe, Michael
2014-03-04
A test device for measuring permeability of a barrier material. An exemplary device comprises a test card having a thin-film conductor-pattern formed thereon and an edge seal which seals the test card to the barrier material. Another exemplary embodiment is an electrical calcium test device comprising: a test card an impermeable spacer, an edge seal which seals the test card to the spacer and an edge seal which seals the spacer to the barrier material.
[The continuous graphic presentation of interdepartmental results (author's transl)].
Berger, J; Hirsch, H
1976-10-01
The results of interdepartmental determinations can be clearly presented in the laboratory in two ways: 1. Entry on a test card, according to Shewhart, as used in internal quality control. 2. Entry on a test card, constructed on the principle of the Cusum test. By the latter procedure, systematic errors are detected sooner than with the usual test card. A graphic variant of the Cusum test is described; a V-mask is not required; the card superficially resembles the usual control card, and the calculation time is minimal. This method may also be used to advantage in internal quality control.
NASA Astrophysics Data System (ADS)
Ahmad, Nabihah; Rifen, A. Aminurdin M.; Helmy Abd Wahab, Mohd
2016-11-01
Automated Teller Machine (ATM) is an electronic banking outlet that allows bank customers to complete a banking transactions without the aid of any bank official or teller. Several problems are associated with the use of ATM card such card cloning, card damaging, card expiring, cast skimming, cost of issuance and maintenance and accessing customer account by third parties. The aim of this project is to give a freedom to the user by changing the card to biometric security system to access the bank account using Advanced Encryption Standard (AES) algorithm. The project is implemented using Field Programmable Gate Array (FPGA) DE2-115 board with Cyclone IV device, fingerprint scanner, and Multi-Touch Liquid Crystal Display (LCD) Second Edition (MTL2) using Very High Speed Integrated Circuit Hardware (VHSIC) Description Language (VHDL). This project used 128-bits AES for recommend the device with the throughput around 19.016Gbps and utilized around 520 slices. This design offers a secure banking transaction with a low rea and high performance and very suited for restricted space environments for small amounts of RAM or ROM where either encryption or decryption is performed.
Evaluation of Nucleic Acid Preservation Cards for West Nile Virus Testing in Dead Birds
Foss, Leslie; Reisen, William K.; Fang, Ying; Kramer, Vicki; Padgett, Kerry
2016-01-01
The California West Nile virus (WNV) Dead Bird Surveillance Program (DBSP) is an important component of WNV surveillance in the state. We evaluated FTA™ and RNASound™ cards as an alternative method for sampling dead birds for WNV molecular testing as these cards allow for more cost effective, rapid, and safer diagnostic sampling than the shipment of bird carcasses. To evaluate accuracy of results among avian sampling regimes, Reverse-Transcription Polymerase Chain Reaction (RT-PCR) results from FTA™ and RNASound™ cards were compared with results from kidney tissue, brain tissue, or oral swabs in lysis buffer in 2012–2013. In addition, RT-PCR results were compared with results from oral swabs tested by rapid antigen tests (RAMP™ and VecTOR™). While test results from the cards were not as sensitive as kidney tissue testing, they were more likely to provide accurate results than rapid antigen tests, and detected WNV in corvids as well as in other passerines, raptors, and waterfowl. Overall, WNV RT-PCR cycle threshold (Ct) scores from the cards were higher than those from tissue testing, but both card products displayed high sensitivity and specificity. American Crow samples provided the highest sensitivity. The cards also proved to be easier and more convenient vehicles for collecting and shipping samples, and in 2014 our program launched use of RNASound™ cards in the DBSP. Both FTA™ and RNASound™ products displayed 96% agreement with tissue results and are an adequate alternative sampling method for WNV dead bird testing. PMID:27341492
Maurer, Kathryn; Luo, Hongxue; Shen, Zhiyong; Wang, Guixiang; Du, Hui; Wang, Chun; Liu, Xiaobo; Wang, Xiamen; Qu, Xinfeng; Wu, Ruifang; Belinson, Jerome
2016-03-01
Solid media transport can be used to design adaptable cervical cancer screening programs but currently is limited by one card with published data. To develop and evaluate a solid media transport card for use in high-risk human papillomavirus detection (HR-HPV). The Preventative Oncology International (POI) card was constructed using PK 226 paper(®) treated with cell-lysing solution and indicating dye. Vaginal samples were applied to the POI card and the indicating FTA (iFTA) elute card. A cervical sample was placed in liquid media. All specimens were tested for HR-HPV. Color change was assessed at sample application and at card processing. Stability of the POI card and iFTA elute card was tested at humidity. 319 women were enrolled. Twelve women had at least one insufficient sample with no difference between media (p=0.36). Compared to liquid samples, there was good agreement for HR-HPV detection with kappa of 0.81 (95% CI 0.74-0.88) and 0.71 (95% CI 0.62-0.79) for the POI and iFTA elute card respectively. Sensitivity for ≥CIN2 was 100% (CI 100-100%), 95.1% (CI 92.7-97.6%), and 93.5% (CI 90.7-96.3%) for the HR-HPV test from the liquid media, POI card, and iFTA elute card respectively. There was no color change of the POI card noted in humidity but the iFTA elute card changed color at 90% humidity. The POI card is suitable for DNA transport and HR-HPV testing. This card has the potential to make cervical cancer screening programs more affordable worldwide. Copyright © 2015 Elsevier B.V. All rights reserved.
De Neys, Wim
2006-06-01
Human reasoning has been shown to overly rely on intuitive, heuristic processing instead of a more demanding analytic inference process. Four experiments tested the central claim of current dual-process theories that analytic operations involve time-consuming executive processing whereas the heuristic system would operate automatically. Participants solved conjunction fallacy problems and indicative and deontic selection tasks. Experiment 1 established that making correct analytic inferences demanded more processing time than did making heuristic inferences. Experiment 2 showed that burdening the executive resources with an attention-demanding secondary task decreased correct, analytic responding and boosted the rate of conjunction fallacies and indicative matching card selections. Results were replicated in Experiments 3 and 4 with a different secondary-task procedure. Involvement of executive resources for the deontic selection task was less clear. Findings validate basic processing assumptions of the dual-process framework and complete the correlational research programme of K. E. Stanovich and R. F. West (2000).
The Lick-Gaertner automatic measuring system
NASA Technical Reports Server (NTRS)
Vasilevskis, S.; Popov, W. A.
1971-01-01
The Lick-Gaertner automatic equipment has been designed mainly for the measurement of stellar proper motions with reference to galaxies, and consists of two main components: the survey machine and the automatic measuring engine. The survey machine is used for initial inspection and selection of objects for subsequent measurement. Two plates, up to 17 x 17 inches each, are surveyed simultaneously by means of projection on a screen. The approximate positions of objects selected are measured by two optical screws: helical lines cut through an aluminum coating on glass cylinders. These approximate coordinates to a precision of the order of 0.03mm are transmitted to a card punch by encoders connected with the cylinders.
81. AVALON DAM Photographic copy of construction drawing c1908 ...
81. AVALON DAM - Photographic copy of construction drawing c1908 (from aperture card located at Bureau of Reclamation, Salt Lake City) UNTITLED DRAWING OF AUTOMATIC FLOOD GATES. GATE DETAILS - Carlsbad Irrigation District, Avalon Dam, On Pecos River, 4 miles North of Carlsbad, Carlsbad, Eddy County, NM
80. AVALON DAM Photographic copy of construction drawing c1908 ...
80. AVALON DAM - Photographic copy of construction drawing c1908 (from aperture card located at Bureau of Reclamation, Salt Lake City). UNTITLED DRAWING OF AUTOMATIC FLOOD GATES. PARTIAL PLAN AND ELEVATION - Carlsbad Irrigation District, Avalon Dam, On Pecos River, 4 miles North of Carlsbad, Carlsbad, Eddy County, NM
Outpatient Treatment of Dyslexia through Stimulation of the Cerebral Hemispheres.
ERIC Educational Resources Information Center
Kappers, E. Jan
1997-01-01
Integrated treatment methods of neuropsychological and cognitive origin were evaluated with 80 Dutch children (ages 6-15) with severe dyslexia. Treatment with flash cards, which exercised automatic letter-sound conversions, had a robust and slight effect in preclinical and clinical phases respectively, whereas hemisphere stimulation produced…
Neural network applications in telecommunications
NASA Technical Reports Server (NTRS)
Alspector, Joshua
1994-01-01
Neural network capabilities include automatic and organized handling of complex information, quick adaptation to continuously changing environments, nonlinear modeling, and parallel implementation. This viewgraph presentation presents Bellcore work on applications, learning chip computational function, learning system block diagram, neural network equalization, broadband access control, calling-card fraud detection, software reliability prediction, and conclusions.
Automatic Rotational Sky Quality Meter (R-SQM) Design and Software for Astronomical Observatories
NASA Astrophysics Data System (ADS)
Dogan, E.; Ozbaldan, E. E.; Shameoni, Niaei M.; Yesilyaprak, C.
2016-12-01
We have presented the new design of Sky Quality Meter (SQM) device that is an automatic rotational model of sky quality meter (R-SQM) carried out by DAG (Eastern Anatolia Observatory) Technical Team. R-SQM is required for determining the long-term changes of sky quality of an astronomical observatory and consists of four SQM devices mounted on a rotating shaft with different angles for scanning all sky. This system is controlled by a Raspberry Pi control card and a step motor with its driver and a special software.
Evaluation of a Short-Form of the Berg Card Sorting Test
Fox, Christopher J.; Mueller, Shane T.; Gray, Hilary M.; Raber, Jacob; Piper, Brian J.
2013-01-01
The Psychology Experimental Building Language http://pebl.sourceforge.net/ Berg Card Sorting Test is an open-source neurobehavioral test. Participants (N = 207, ages 6 to 74) completed the Berg Card Sorting Test. Performance on the first 64 trials were isolated and compared to that on the full-length (128 trials) test. Strong correlations between the short and long forms (total errors: r = .87, perseverative response: r = .83, perseverative errors r = .77, categories completed r = .86) support the Berg Card Sorting Test-64 as an abbreviated alternative for the full-length executive function test. PMID:23691107
76 FR 3180 - Market Test of Gift Cards
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-19
... POSTAL REGULATORY COMMISSION [Docket No. MT2011-2; Order No. 647] Market Test of Gift Cards AGENCY... Service proposal to conduct a 2-year market test involving the sale of gift cards. This document describes the proposed test, addresses procedural aspects of the filing, and invites public comment. DATES...
78 FR 39020 - Market Test on Gift Cards
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-28
... POSTAL REGULATORY COMMISSION [Docket No. MT2011-2; Order No. 1755] Market Test on Gift Cards... Service filing requesting a temporary extension of a market test on gift cards. This notice informs the... market test under 39 U.S.C. 3641(d).\\1\\ The market test is set to expire June 27, 2013. Motion at 1. The...
Cantón, Rafael; Alós, Juan Ignacio; Baquero, Fernando; Calvo, Jorge; Campos, José; Castillo, Javier; Cercenado, Emilia; Domínguez, M Angeles; Liñares, Josefina; López-Cerezo, Lorena; Marco, Francesc; Mirelis, Beatriz; Morosini, María-Isabel; Navarro, Ferran; Oliver, Antonio; Pérez-Trallero, Emilio; Torres, Carmen; Martínez-Martínez, Luis
2007-01-01
The number of clinical microbiology laboratories that have incorporated automatic susceptibility testing devices has increased in recent years. The majority of these systems determine MIC values using microdilution panels or specific cards, with grouping into clinical categories (susceptible, intermediate or resistant) and incorporate expert systems to infer resistance mechanisms. This document presents the recommendations of a group of experts designated by Grupo de Estudio de los Mecanismos de Acción y Resistencia a los Antimicrobianos (GEMARA, Study group on mechanisms of action and resistance to antimicrobial agents) and Mesa Española de Normalización de la Sensibilidad y Resistencia a los Antimicrobianos (MENSURA, Spanish Group for Normalizing Antimicrobial Susceptibility and Antimicrobial Resistance), with the aim of including antimicrobial agents and selecting concentrations for the susceptibility testing panels of automatic systems. The following have been defined: various antimicrobial categories (A: must be included in the study panel; B: inclusion is recommended; and C: inclusion is secondary, but may facilitate interpretative reading of the antibiogram) and groups (0: not used in therapeutics but may facilitate the detection of resistance mechanisms; 1: must be studied and always reported; 2: must be studied and selectively reported; 3: must be studied and reported at a second level; and 4: should be studied in urinary tract pathogens isolated in urine and other specimens). Recommended antimicrobial concentrations are adapted from the breakpoints established by EUCAST, CLSI and MENSURA. This approach will lead to more accurate susceptibility testing results with better detection of resistance mechanisms, and allowing to reach the clinical goal of the antibiogram.
Pettit performs the EPIC Card Testing and X2R10 Software Transition
2011-12-28
ISS030-E-022574 (28 Dec. 2011) -- NASA astronaut Don Pettit (foreground),Expedition 30 flight engineer, performs the Enhanced Processor and Integrated Communications (EPIC) card testing and X2R10 software transition. The software transition work will include EPIC card testing and card installations, and monitoring of the upgraded Multiplexer/ Demultiplexer (MDM) computers. Dan Burbank, Expedition 30 commander, is setting up a camcorder in the background.
Pettit performs the EPIC Card Testing and X2R10 Software Transition
2011-12-28
ISS030-E-022575 (28 Dec. 2011) -- NASA astronaut Don Pettit (foreground),Expedition 30 flight engineer, performs the Enhanced Processor and Integrated Communications (EPIC) card testing and X2R10 software transition. The software transition work will include EPIC card testing and card installations, and monitoring of the upgraded Multiplexer/ Demultiplexer (MDM) computers. Dan Burbank, Expedition 30 commander, is setting up a camcorder in the background.
Evaluation of Four Bedside Test Systems for Card Performance, Handling and Safety.
Giebel, Felix; Picker, Susanne M; Gathof, Birgit S
2008-01-01
SUMMARY: OBJECTIVE: Pretransfusion ABO compatibility testing is a simple and required precaution against ABO-incompatible transfusion, which is one of the greatest threats in transfusion medicine. While distinct agglutination is most important for correct test interpretation, protection against infectious diseases and ease of handling are crucial for accurate test performance. Therefore, the aim of this study was to evaluate differences in test card design, handling, and user safety. DESIGN: Four different bedside test cards with pre-applied antibodies were evaluated by 100 medical students using packed red blood cells of different ABO blood groups. Criteria of evaluation were: agglutination, labelling, handling, and safety regarding possible user injuries. Criteria were rated subjectively according to German school notes ranging from 1 = very good to 6 = very bad/insufficient. RESULTS: Overall, all cards received very good/good marks. The ABO blood group was identified correctly in all cases. Three cards (no. 1, no. 3, no. 4) received statistically significant (p < 0.008) prominence (mean values shown) concerning clearness of agglutination (1.7-1.9 vs. 2.4 for no. 2). Systems with dried antibodies (no. 2, no. 4) outmatched the other systems with respect to overall test system performance (2.0 vs. 2.8-2.9), labelling (1.5 vs. 2.2-2.4), handling (1.9-2.0 vs. 2.5), and user safety (2.5 vs. 3.4). Analysis of card self-explanation revealed no remarkable differences. CONCLUSION: Despite good performance of all card systems tested, the best results when including all criteria evaluated were obtained with card no. 4 (particularly concerning clear agglutination), followed by cards no. 2, no. 1, and no. 3.
2010-09-01
cards and software in almost any computer can communicate with each other seamlessly. The cable modem protocol is another example of competing...streaming: it means that special client software applications known as podcatchers (such as Apple Inc.’s iTunes or Nullsoft’s Winamp) can automatically
Fabrication of Cantilever-Bump Type Si Probe Card
NASA Astrophysics Data System (ADS)
Park, Jeong-Yong; Lee, Dong-Seok; Kim, Dong-Kwon; Lee, Jong-Hyun
2000-12-01
Probe card is most important part in the test system which selects the good or bad chip of integrated circuit (IC) chips. Silicon vertical probe card is able to test multiple semiconductor chips simultaneously. We presented cantilever-bump type vertical probe card. It was fabricated by dry etching using RIE(reactive ion etching) technique and porous silicon micromachining using silicon direct bonded (SDB) wafer. Cantilevers and bumps were fabricated by isotropic etching using RIE@. 3-dimensional structures were formed by porous silicon micromachining technique using SDB wafer. Contact resistance of fabricated probe card was less than 2 Ω and its life time was more than 200,000 turns. The process used in this work is very simple and reproducible, which has good controllability in the tip dimension and spacing. It is expected that the fabricated probe card can reduce testing time, can promote productivity and enables burn-in test.
Status and Power Do Not Modulate Automatic Imitation of Intransitive Hand Movements
Farmer, Harry; Carr, Evan W.; Svartdal, Marita; Winkielman, Piotr; Hamilton, Antonia F. de C.
2016-01-01
The tendency to mimic the behaviour of others is affected by a variety of social factors, and it has been argued that such “mirroring” is often unconsciously deployed as a means of increasing affiliation during interpersonal interactions. However, the relationship between automatic motor imitation and status/power is currently unclear. This paper reports five experiments that investigated whether social status (Experiments 1, 2, and 3) or power (Experiments 4 and 5) had a moderating effect on automatic imitation (AI) in finger-movement tasks, using a series of different manipulations. Experiments 1 and 2 manipulated the social status of the observed person using an associative learning task. Experiment 3 manipulated social status via perceived competence at a simple computer game. Experiment 4 manipulated participants’ power (relative to the actors) in a card-choosing task. Finally, Experiment 5 primed participants using a writing task, to induce the sense of being powerful or powerless. No significant interactions were found between congruency and social status/power in any of the studies. Additionally, Bayesian hypothesis testing indicated that the null hypothesis should be favoured over the experimental hypothesis in all five studies. These findings are discussed in terms of their implications for AI tasks, social effects on mimicry, and the hypothesis of mimicry as a strategic mechanism to promote affiliation. PMID:27096167
Testa, Massimiliano; Pollard, John
2007-01-01
Each patient is supplied with a smart-card containing a Radio Frequency IDentification (RFID) chip storing a unique identification code. The patient places the Smart-card on a pill-dispenser unit containing an RFID reader. The RFID chip is read and the code sent to a Base-station via a wireless Bluetooth link. A database containing both patient details and treatment information is queried at the Base-station using the RFID as the search key. The patient's treatment data (i.e., drug names, quantities, time, etc.) are retrieved and sent back to the pill-dispenser unit via Bluetooth. Appropriate quantities of the required medications are automatically dispensed, unless the patient has already taken his/her daily dose. Safe, confidential communication and operation is ensured.
[Cardiovascular circulation feedback control treatment instrument].
Ge, Yu-zhi; Zhu, Xing-huan; Sheng, Guo-tai; Cao, Ping-liang; Liu, Dong-sheng; Wu, Zhi-ting
2005-07-01
The cardiovascular circulation feedback control treatment instrument (CFCTI) is an automatic feedback control treatment system, which has the function of monitoring, alarming, trouble self-diagnosis and testing on the line in the closed loop. The instrument is designed based on the successful clinical experiences and the data are inputted into the computer in real-time through a pressure sensor and A/D card. User interface window is set up for the doctor's choosing different medicine. The orders are outputted to control the dose of medicine through the transfusion system. The response to medicine is updated continually. CFCTI can avoid the man-made errors and the long interval of sampling. Its reliability and accuracy in rescuing the critical patients are much higher than the traditional methods.
Coding hazardous tree failures for a data management system
Lee A. Paine
1978-01-01
Codes for automatic data processing (ADP) are provided for hazardous tree failure data submitted on Report of Tree Failure forms. Definitions of data items and suggestions for interpreting ambiguously worded reports are also included. The manual is intended to insure the production of accurate and consistent punched ADP cards which are used in transfer of the data to...
Vital-Durand, F
1996-01-01
Acuity cards are being more commonly used in clinical and screening practice. The author describes his experience from over 6000 infants tested with the method, using two commercially available sets of cards to provide users with comprehensive guidelines to allow them to get the most out of this useful test.
A Simple Homemade Polarised Sunglasses Test Card
ERIC Educational Resources Information Center
Bamdad, Farzad
2016-01-01
In this article construction of a simple and inexpensive test card which can be used to demonstrate the polarisation ability of sunglasses is described. The card was fabricated simply by using a piece of polariser sheet with one to three layers of cellophane tape fixed on it.
Isothermal thermogravimetric data acquisition analysis system
NASA Technical Reports Server (NTRS)
Cooper, Kenneth, Jr.
1991-01-01
The description of an Isothermal Thermogravimetric Analysis (TGA) Data Acquisition System is presented. The system consists of software and hardware to perform a wide variety of TGA experiments. The software is written in ANSI C using Borland's Turbo C++. The hardware consists of a 486/25 MHz machine with a Capital Equipment Corp. IEEE488 interface card. The interface is to a Hewlett Packard 3497A data acquisition system using two analog input cards and a digital actuator card. The system provides for 16 TGA rigs with weight and temperature measurements from each rig. Data collection is conducted in three phases. Acquisition is done at a rapid rate during initial startup, at a slower rate during extended data collection periods, and finally at a fast rate during shutdown. Parameters controlling the rate and duration of each phase are user programmable. Furnace control (raising and lowering) is also programmable. Provision is made for automatic restart in the event of power failure or other abnormal terminations. Initial trial runs were conducted to show system stability.
Macdonald, S A; Wells, S L; Giesbrecht, N; West, P M
1999-05-01
In 1994, regulatory changes were introduced in Ontario, Canada, permitting the purchase of alcoholic beverages with credit cards at government-operated liquor stores. Two objectives of this study were: (1) to compare the characteristics of credit card shoppers with non credit card shoppers at liquor stores, and (2) to assess whether changes occurred in alcohol consumption patterns among shoppers following the introduction of credit cards. Random digit dialing was used to interview 2,039 telephone participants prior to the introduction of credit cards (Time 1); 1,401 of these subjects were contacted 1 year later (Time 2). Independent sample t tests were used to compare credit card shoppers with shoppers not using credit cards, and paired t tests were performed to assess whether drinking behaviors changed from Time 1 to Time 2. The credit card shoppers were more likely than the non credit card shoppers to be highly educated (p < .001) and to have high incomes (p < .05). Credit card shoppers drank an average of 6.3 drinks over the previous week compared with 4.0 drinks among non credit card shoppers (p < .01). Although the overall amount of alcohol consumed among credit card shoppers dropped from 6.7 drinks at Time 1 to 6.3 at Time 2 (NS), credit card shoppers reported drinking significantly more often after credit cards were introduced (p < .05). The results suggest that credit cards may not present public health problems since significant increases in alcohol consumption among credit card shoppers were not found.
Formative and Summative Approaches to Effectiveness Indicators.
ERIC Educational Resources Information Center
McLarty, Joyce R.; Hudson, Susan
The development of the Tennessee school system Commissioner's Report Card (CRC) and the School Report Card--later named the Tennessee School Improvement Project (TSIP)--is described. The report card project began in 1984 when statewide mandated achievement testing was introduced. The first CRC included limited results of such testing. The first…
Genic insights from integrated human proteomics in GeneCards.
Fishilevich, Simon; Zimmerman, Shahar; Kohn, Asher; Iny Stein, Tsippi; Olender, Tsviya; Kolker, Eugene; Safran, Marilyn; Lancet, Doron
2016-01-01
GeneCards is a one-stop shop for searchable human gene annotations (http://www.genecards.org/). Data are automatically mined from ∼120 sources and presented in an integrated web card for every human gene. We report the application of recent advances in proteomics to enhance gene annotation and classification in GeneCards. First, we constructed the Human Integrated Protein Expression Database (HIPED), a unified database of protein abundance in human tissues, based on the publically available mass spectrometry (MS)-based proteomics sources ProteomicsDB, Multi-Omics Profiling Expression Database, Protein Abundance Across Organisms and The MaxQuant DataBase. The integrated database, residing within GeneCards, compares favourably with its individual sources, covering nearly 90% of human protein-coding genes. For gene annotation and comparisons, we first defined a protein expression vector for each gene, based on normalized abundances in 69 normal human tissues. This vector is portrayed in the GeneCards expression section as a bar graph, allowing visual inspection and comparison. These data are juxtaposed with transcriptome bar graphs. Using the protein expression vectors, we further defined a pairwise metric that helps assess expression-based pairwise proximity. This new metric for finding functional partners complements eight others, including sharing of pathways, gene ontology (GO) terms and domains, implemented in the GeneCards Suite. In parallel, we calculated proteome-based differential expression, highlighting a subset of tissues that overexpress a gene and subserving gene classification. This textual annotation allows users of VarElect, the suite's next-generation phenotyper, to more effectively discover causative disease variants. Finally, we define the protein-RNA expression ratio and correlation as yet another attribute of every gene in each tissue, adding further annotative information. The results constitute a significant enhancement of several GeneCards sections and help promote and organize the genome-wide structural and functional knowledge of the human proteome. Database URL:http://www.genecards.org/. © The Author(s) 2016. Published by Oxford University Press.
Richardson, J.H.
1958-03-01
This patent pertains to electronic circuits for measuring the intensity of light and is especially concerned with measurement between preset light thresholds. Such a circuit has application in connection with devices for reading-out information stored on punch cards or tapes where the cards and tapes are translucent. By the novel arrangement of this invention thc sensitivity of a gas phototube is maintained at a low value when the light intensity is below a first threshold level. If the light level rises above the first threshold level, the tube is rendered highly sensitive and an output signal will vary in proportion to the light intensity change. When the light level decreases below a second threshold level, the gas phototube is automatically rendered highly insensitive. Each of these threshold points is adjustable.
Card-Sorting Usability Tests of the WMU Libraries' Web Site
ERIC Educational Resources Information Center
Whang, Michael
2008-01-01
This article describes the card-sorting techniques used by several academic libraries, reports and discusses the results of card-sorting usability tests of the Western Michigan University Libraries' Web site, and reveals how the WMU libraries incorporated the findings into a new Web site redesign, setting the design direction early on. The article…
Observations of long delays to detonation in propellant for tests with marginal card gaps
NASA Technical Reports Server (NTRS)
Olinger, B.
1980-01-01
Using the large-scale card gap tests with pin and high-speed framing camera techniques, VRP propellant, and presumably others, were found to transit to detonation at marginal gaps after a long delay. In addition, manganin-constantan gauge measurements were made in the card gap stack.
The Ohio Contrast Cards: Visual Performance in a Pediatric Low-vision Site
Hopkins, Gregory R.; Dougherty, Bradley E.; Brown, Angela M.
2017-01-01
SIGNIFICANCE This report describes the first clinical use of the Ohio Contrast Cards, a new test that measures the maximum spatial contrast sensitivity of low-vision patients who cannot recognize and identify optotypes and for whom the spatial frequency of maximum contrast sensitivity is unknown. PURPOSE To compare measurements of the Ohio Contrast Cards to measurements of three other vision tests and a vision-related quality-of-life questionnaire obtained on partially sighted students at Ohio State School for the Blind. METHODS The Ohio Contrast Cards show printed square-wave gratings at very low spatial frequency (0.15 cycle/degree). The patient looks to the left/right side of the card containing the grating. Twenty-five students (13 to 20 years old) provided four measures of visual performance: two grating card tests (the Ohio Contrast Cards and the Teller Acuity Cards) and two letter charts (the Pelli-Robson contrast chart and the Bailey-Lovie acuity chart). Spatial contrast sensitivity functions were modeled using constraints from the grating data. The Impact of Vision Impairment on Children questionnaire measured vision-related quality of life. RESULTS Ohio Contrast Card contrast sensitivity was always less than 0.19 log10 units below the maximum possible contrast sensitivity predicted by the model; average Pelli-Robson letter contrast sensitivity was near the model prediction, but 0.516 log10 units below the maximum. Letter acuity was 0.336 logMAR below the grating acuity results. The model estimated the best testing distance in meters for optimum Pelli-Robson contrast sensitivity from the Bailey-Lovie acuity as distance = 1.5 − logMAR for low-vision patients. Of the four vision tests, only Ohio Contrast Card contrast sensitivity was independently and statistically significantly correlated with students' quality of life. CONCLUSIONS The Ohio Contrast Cards combine a grating stimulus, a looking indicator behavior, and contrast sensitivity measurement. They show promise for the clinical objective of advising the patient and his/her caregivers about the success the patient is likely to enjoy in tasks of everyday life. PMID:28972542
Digital tape unit test facility software
NASA Technical Reports Server (NTRS)
Jackson, J. T.
1971-01-01
Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.
Signal Waveform Generator Performance Test
DOT National Transportation Integrated Search
1992-01-01
A signal waveform generator (SWG) was tested to determine its suitability for use in testing crash test data acquisition systems. The outputs of the SWG were recorded by a precise, high speed data acquisitions card plugged into the option card slot o...
Gurulingappa, Harsha; Toldo, Luca; Rajput, Abdul Mateen; Kors, Jan A; Taweel, Adel; Tayrouz, Yorki
2013-11-01
The aim of this study was to assess the impact of automatically detected adverse event signals from text and open-source data on the prediction of drug label changes. Open-source adverse effect data were collected from FAERS, Yellow Cards and SIDER databases. A shallow linguistic relation extraction system (JSRE) was applied for extraction of adverse effects from MEDLINE case reports. Statistical approach was applied on the extracted datasets for signal detection and subsequent prediction of label changes issued for 29 drugs by the UK Regulatory Authority in 2009. 76% of drug label changes were automatically predicted. Out of these, 6% of drug label changes were detected only by text mining. JSRE enabled precise identification of four adverse drug events from MEDLINE that were undetectable otherwise. Changes in drug labels can be predicted automatically using data and text mining techniques. Text mining technology is mature and well-placed to support the pharmacovigilance tasks. Copyright © 2013 John Wiley & Sons, Ltd.
A Preliminary Study of Clinical Abbreviation Disambiguation in Real Time.
Wu, Y; Denny, J C; Rosenbloom, S T; Miller, R A; Giuse, D A; Song, M; Xu, H
2015-01-01
To save time, healthcare providers frequently use abbreviations while authoring clinical documents. Nevertheless, abbreviations that authors deem unambiguous often confuse other readers, including clinicians, patients, and natural language processing (NLP) systems. Most current clinical NLP systems "post-process" notes long after clinicians enter them into electronic health record systems (EHRs). Such post-processing cannot guarantee 100% accuracy in abbreviation identification and disambiguation, since multiple alternative interpretations exist. Authors describe a prototype system for real-time Clinical Abbreviation Recognition and Disambiguation (rCARD) - i.e., a system that interacts with authors during note generation to verify correct abbreviation senses. The rCARD system design anticipates future integration with web-based clinical documentation systems to improve quality of healthcare records. When clinicians enter documents, rCARD will automatically recognize each abbreviation. For abbreviations with multiple possible senses, rCARD will show a ranked list of possible meanings with the best predicted sense at the top. The prototype application embodies three word sense disambiguation (WSD) methods to predict the correct senses of abbreviations. We then conducted three experments to evaluate rCARD, including 1) a performance evaluation of different WSD methods; 2) a time evaluation of real-time WSD methods; and 3) a user study of typing clinical sentences with abbreviations using rCARD. Using 4,721 sentences containing 25 commonly observed, highly ambiguous clinical abbreviations, our evaluation showed that the best profile-based method implemented in rCARD achieved a reasonable WSD accuracy of 88.8% (comparable to SVM - 89.5%) and the cost of time for the different WSD methods are also acceptable (ranging from 0.630 to 1.649 milliseconds within the same network). The preliminary user study also showed that the extra time costs by rCARD were about 5% of total document entry time and users did not feel a significant delay when using rCARD for clinical document entry. The study indicates that it is feasible to integrate a real-time, NLP-enabled abbreviation recognition and disambiguation module with clinical documentation systems.
ERIC Educational Resources Information Center
Gilbert, Lynn E.; Shipman, Virginia C.
The Johns Hopkins Perceptual Test, a brief measure of intelligence in children, requires the child to choose a form identical to a standard. It consists of 3 practice and 30 test items, all involving black geometric figures printed on white cards. There is one booklet for stimulus cards and one for response cards. The child is presented with a…
saltPAD: A New Analytical Tool for Monitoring Salt Iodization in Low Resource Settings
Myers, Nicholas M.; Strydom, Emmerentia Elza; Sweet, James; Sweet, Christopher; Spohrer, Rebecca; Dhansay, Muhammad Ali; Lieberman, Marya
2016-01-01
We created a paper test card that measures a common iodizing agent, iodate, in salt. To test the analytical metrics, usability, and robustness of the paper test card when it is used in low resource settings, the South African Medical Research Council and GroundWork performed independent validation studies of the device. The accuracy and precision metrics from both studies were comparable. In the SAMRC study, more than 90% of the test results (n=1704) were correctly classified as corresponding to adequately or inadequately iodized salt. The cards are suitable for market and household surveys to determine whether salt is adequately iodized. Further development of the cards will improve their utility for monitoring salt iodization during production. PMID:29942380
A comparison of standard serological tests for the diagnosis of bovine brucellosis in Canada.
Stemshorn, B W; Forbes, L B; Eaglesome, M D; Nielsen, K H; Robertson, F J; Samagh, B S
1985-01-01
Six agglutination and two complement fixation tests were compared with respect to specificity, sensitivity and relative sensitivity for the serodiagnosis of bovine brucellosis. Based on 1051 sera from brucellosis free herds, the specificity of the tests was 98.9% for the buffered plate antigen test (BPAT), 99.2% and 99.3% for the standard tube and plate agglutination tests (STAT and SPAT), respectively, and 99.8% for the 2-mercaptoethanol test (2MET). On this small sample, the rose bengal plate test (RBPT), card test (CARD) and the complement fixation test (CFT) correctly classed all sera as negative. On a sample of 167 culture positive cattle, the sensitivities of the tests were CFT: 79.0%, BPAT: 75.4, RBPT: 74.9%, CARD: 74.3%, SPAT: 73.1%, STAT: 68.9%, and 2MET: 59.9%. All tests combined detected only 82% of these infected cattle. Analysis of the relative sensitivity of the six agglutination tests gave the following ranking: BPAT greater than RBPT greater than CARD greater than SPAT greater than STAT. The 2MET ranked between the BPAT and RBPT or between the RBPT and CARD depending on the analysis used. The use of the BPAT as a screening test is recommended provided that a test of high specificity and sensitivity such as the CFT is used to confirm screening test reactions. PMID:4075239
[Ophthalmologic reading charts : Part 2: Current logarithmically scaled reading charts].
Radner, W
2016-12-01
To analyze currently available reading charts regarding print size, logarithmic print size progression, and the background of test-item standardization. For the present study, the following logarithmically scaled reading charts were investigated using a measuring microscope (iNexis VMA 2520; Nikon, Tokyo): Eschenbach, Zeiss, OCULUS, MNREAD (Minnesota Near Reading Test), Colenbrander, and RADNER. Calculations were made according to EN-ISO 8596 and the International Research Council recommendations. Modern reading charts and cards exhibit a logarithmic progression of print sizes. The RADNER reading charts comprise four different cards with standardized test items (sentence optotypes), a well-defined stop criterion, accurate letter sizes, and a high print quality. Numbers and Landolt rings are also given in the booklet. The OCULUS cards have currently been reissued according to recent standards and also exhibit a high print quality. In addition to letters, numbers, Landolt rings, and examples taken from a timetable and the telephone book, sheet music is also offered. The Colenbrander cards use short sentences of 44 characters, including spaces, and exhibit inaccuracy at smaller letter sizes, as do the MNREAD cards. The MNREAD cards use sentences of 60 characters, including spaces, and have a high print quality. Modern reading charts show that international standards can be achieved with test items similar to optotypes, by using recent technology and developing new concepts of test-item standardization. Accurate print sizes, high print quality, and a logarithmic progression should become the minimum requirements for reading charts and reading cards in ophthalmology.
The Cold Dark Matter Search test stand warm electronics card
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hines, Bruce; /Colorado U., Denver; Hansen, Sten
A card which does the signal processing for four SQUID amplifiers and two charge sensitive channels is described. The card performs the same functions as is presently done with two custom 9U x 280mm Eurocard modules, a commercial multi-channel VME digitizer, a PCI to GPIB interface, a PCI to VME interface and a custom built linear power supply. By integrating these functions onto a single card and using the power over Ethernet standard, the infrastructure requirements for instrumenting a Cold Dark Matter Search (CDMS) detector test stand are significantly reduced.
Crib Card Use During Tests: Helpful or a Crutch?
ERIC Educational Resources Information Center
Funk, Steven C.; Dickson, K. Laurie
2011-01-01
The authors experimentally investigated the effect of crib cards on exam performance and student learning. Fifty-one students expected to use their prepared crib cards during an exam. However, they first completed an unexpected pretest without their crib card. Students performed significantly worse on the pretest than on identical questions when…
Advances in Telemetry Capability as Demonstrated on an Affordable Precision Mortar
2012-06-01
of high rate data and then broadcasting it over the rest of the flight test. Lastly an on-board data storage implementation using a MicroSD card is...broadcasting it over the rest of the flight test. Lastly an on- board data storage implementation using a MicroSD card is presented. KEY WORDS...the flight test. Lastly an on-board data storage implementation using a MicroSD card is presented. 2 GPS INTEGRATION Although ARL has
Njenga, S M; Wamae, C N
2001-10-01
An immunochromatographic card test (ICT) that uses fingerprick whole blood instead of serum for diagnosis of bancroftian filariasis has recently been developed. The card test was validated in the field in Kenya by comparing its sensitivity to the combined sensitivity of Knott's concentration and counting chamber methods. A total of 102 (14.6%) and 117 (16.7%) persons was found to be microfilaremic by Knott's concentration and counting chamber methods, respectively. The geometric mean intensities (GMI) were 74.6 microfilariae (mf)/ml and 256.5 mf/ml by Knott's concentration and counting chamber methods, respectively. All infected individuals detected by both Knott's concentration and counting chamber methods were also antigen positive by the ICT filariasis card test (100% sensitivity). Further, of 97 parasitologically amicrofilaremic persons, 24 (24.7%) were antigen positive by the ICT. The overall prevalence of antigenemia was 37.3%. Of 100 nonendemic area control persons, none was found to be filarial antigen positive (100% specificity). The results show that the new version of the ICT filariasis card test is a simple, sensitive, specific, and rapid test that is convenient in field settings.
Does Mailing a Post Card to Students Improve Response Rates? Issue Brief
ERIC Educational Resources Information Center
Moore, Raeal; Earnhart, Benjamin
2017-01-01
A random sample of students who took the ACT test in either April or June of 2016 were invited to participate in an online survey via an email invitation (N = 35,0471). To study whether mailing post card invitations to students improves response rates, a portion of these test-takers were randomly assigned to be sent a post card. In addition,…
da Cunha Santos, Gilda; Liu, Ni; Tsao, Ming-Sound; Kamel-Reid, Suzanne; Chin, Kayu; Geddie, William R
2010-12-25
The aims of this study were to compare the quality of DNA recovered from fine-needle aspirates (FNAs) stored on Whatman FTA cards with that retrieved from corresponding cell blocks and to determine whether the DNA extracted from the cards is suitable for multiple mutation analyses. FNAs collected from 18 resected lung tumors and cell suspensions from 4 lung cancer cell lines were placed on FTA Indicating Micro Cards and further processed to produce paired formalin-fixed paraffin-embedded (FFPE) cell blocks. Fragment analysis was used for the detection of EGFR exon 19 deletion, and direct sequencing for detection of EGFR exon 21 L858R mutation and exon 2 deletion of KRAS. Corresponding FFPE tissue sections from 2 resection specimens were also tested. Analyses were successful with all FNAs and lung cancer-derived cell lines collected on cards. Polymerase chain reaction failed in 2 cell blocks. For FNAs collected on cards, 5 cases showed EGFR and 3 showed KRAS mutations. Eleven cases were wild type. With cell blocks, 4 cases were found to harbor KRAS and 4 harbored EGFR mutations. All lung cancer-derived cell lines tested positive for their respective mutations, and there was complete agreement between card and cell block FNA samples for EGFR exon 21. For EGFR exon 19, 1 of 18 cases showed discordant results between the card and cell block, and for KRAS 1 of 17. The two resection specimens tested gave concordant results with the FTA card. Storage of cytologic material on FTA cards can maximize and simplify sample procurement for multiple mutational analyses with results similar to those from cell blocks.
Wang, Shao-Ming; Hu, Shang-Ying; Chen, Wen; Chen, Feng; Zhao, Fang-Hui; He, Wei; Ma, Xin-Ming; Zhang, Yu-Qing; Wang, Jian; Sivasubramaniam, Priya; Qiao, You-Lin
2015-11-04
Liquid-state specimen carriers are inadequate for sample transportation in large-scale screening projects in low-resource settings, which necessitates the exploration of novel non-hazardous solid-state alternatives. Studies investigating the feasibility and accuracy of a solid-state human papillomavirus (HPV) sampling medium in combination with different down-stream HPV DNA assays for cervical cancer screening are needed. We collected two cervical specimens from 396 women, aged 25-65 years, who were enrolled in a cervical cancer screening trial. One sample was stored using DCM preservative solution and the other was applied to a Whatman Indicating FTA Elute® card (FTA card). All specimens were processed using three HPV testing methods, including Hybrid capture 2 (HC2), careHPV™, and Cobas®4800 tests. All the women underwent a rigorous colposcopic evaluation that included using a microbiopsy protocol. Compared to the liquid-based carrier, the FTA card demonstrated comparable sensitivity for detecting high grade Cervical Intraepithelial Neoplasia (CIN) using HC2 (91.7 %), careHPV™ (83.3 %), and Cobas®4800 (91.7 %) tests. Moreover, the FTA card showed a higher specificity compared to a liquid-based carrier for HC2 (79.5 % vs. 71.6 %, P = 0.015), comparable specificity for careHPV™ (78.1 % vs. 73.0 %, P > 0.05), but lower specificity for the Cobas®4800 test (62.4 % vs. 69.9 %, P = 0.032). Generally, the FTA card-based sampling medium's accuracy was comparable with that of liquid-based medium for the three HPV testing assays. FTA cards are a promising sample carrier for cervical cancer screening. With further optimization, it can be utilized for HPV testing in areas of varying economic development.
Paper analytical devices for detection of low-quality pharmaceuticals
NASA Astrophysics Data System (ADS)
Weaver, A.; Lieberman, M.
2014-03-01
There is currently no global screening system to detect low quality pharmaceuticals, despite widespread recognition of the public health problems caused by substandard and falsified medicines. In order to fill this void, we designed a rapid field screening test that is interfaced with the mobile phone network. The user scrapes a pill over several reaction areas on a paper test card, and then dips one edge of the card into water to activate dried reagents stored on the paper. These reagents carry out multiple color tests and result in a pattern of colored stripes that give information about the chemical content of the pill. The test cards are inexpensive and instrument-free, and we think they will be a scalable testing option in low resource settings. Studies on falsified drugs archived at the FDA show that the test cards are effective at detecting a wide variety of low-quality formulations of many classes of pharmaceuticals, and field tests are currently under way in Kenya.
Human Factors Assessment of Respiratory Support Pack (RSP) Cue Card
NASA Technical Reports Server (NTRS)
Whitmore, Mihriban; Hudy, Cynthia; Smith, Danielle; Byrne, Vicky
2005-01-01
The Respiratory Support Pack (RSP) is a medical pack onboard the International Space Station (ISS) that contains much of the necessary equipment for providing aid to a conscious or unconscious crewmember in respiratory distress. Inside the RSP lid pocket is a 5.5 by 11 inch paper cue card, which is used by a Crew Medical Officer as the procedure to set up the equipment and deliver oxygen to a crewmember. In training, crewmembers expressed concerns about the readability and usability of the cue card; consequently, updating the cue card was prioritized as an activity to be completed prior to Space Shuttle return-to-flight. The Usability Testing and Analysis Facility at the Johnson Space Center evaluated the current layout of the cue card, and proposed several new cue card designs based on human factors principals. A series of three studies were performed in order to experimentally compare performance with each of the cue card designs. Nonmedically trained personnel used either a redesigned RSP cue card, or the original card to simulate resuscitation (using a mannequin along with the hardware). Time to completion, errors and subjective ratings were recorded. The addition of pictures, colors, borders, and simplification of the flow of information (making minimal changes to the actual procedure content) elicited great benefits during testing. Time to complete RSP procedures was reduced by as much as three minutes with the final cue card design. Detailed results from these studies, as well as general guidelines for cue card design will be discussed.
Paper Test Cards for Presumptive Testing of Very Low Quality Antimalarial Medications
Weaver, Abigail A.; Lieberman, Marya
2015-01-01
Carrying out chemical analysis of antimalarials to detect low-quality medications before they reach a patient is a costly venture. Here, we show that a library of chemical color tests embedded on a paper card can presumptively identify formulations corresponding to very low quality antimalarial drugs. The presence or absence of chloroquine (CQ), doxycycline (DOX), quinine, sulfadoxine, pyrimethamine, and primaquine antimalarial medications, in addition to fillers used in low-quality pharmaceuticals, are indicated by patterns of colors that are generated on the test cards. Test card sensitivity for detection of these pure components ranges from 90% to 100% with no false positives in the absence of pharmaceutical. The color intensities from reactions characteristic of CQ or DOX allowed visual detection of formulations of these medications cut with 60% or 100% filler, although samples cut with 30% filler could not be reliably detected colorimetrically. However, the addition of unexpected fillers, even in 30% quantities, or substitute pharmaceuticals, could sometimes be detected by other color reactions on the test cards. Tests are simple and inexpensive enough to be carried out in clinics, pharmacies, and ports of entry and could provide a screening method to presumptively indicate very low quality medicines throughout the supply chain. PMID:25897064
SPAR reference manual. [for stress analysis
NASA Technical Reports Server (NTRS)
Whetstone, W. D.
1974-01-01
SPAR is a system of related programs which may be operated either in batch or demand (teletype) mode. Information exchange between programs is automatically accomplished through one or more direct access libraries, known collectively as the data complex. Card input is command-oriented, in free-field form. Capabilities available in the first production release of the system are fully documented, and include linear stress analysis, linear bifurcation buckling analysis, and linear vibrational analysis.
Test/QA Plan for Verification of Ozone Indicator Cards
This verification test will address ozone indicator cards (OICs) that provide short-term semi-quantitative measures of ozone concentration in ambient air. Testing will be conducted under the auspices of the U.S. Environmental Protection Agency (EPA) through the Environmental Tec...
ERIC Educational Resources Information Center
Bobbett, Gordon C.; And Others
The relationships among factors reported on school district (SD) report cards were studied for 121 Tennessee SDs. The report cards provided data on student outcomes (achievement test scores) and SD characteristics. Relationships were studied through linear regression, Pearson product moment correlation, and Guttman's partial correlation. Six…
Does Your Library's Web Site Pass the Usability Test? Online Treasures
ERIC Educational Resources Information Center
Balas, Janet L.
2005-01-01
In days that seem very long ago, when the card catalog was the only way to search a library's collection, there was very little debate about the usability of the catalog. Librarians were most concerned about properly formatting catalog cards and, of course, ensuring that the cards were filed correctly. Today, the card catalog has been replaced in…
Wang, Shao-Ming; Hu, Shang-Ying; Chen, Feng; Chen, Wen; Zhao, Fang-Hui; Zhang, Yu-Qing; Ma, Xin-Ming; Qiao, You-Lin
2014-01-01
To make the clinical evaluation of a solid-state human papillomavirus (HPV) sampling medium in combination with an economical HPV testing method (careHPV™) for cervical cancer screening. 396 women aged 25-65 years were enrolled for cervical cancer screening, and four samples were collected. Two samples were collected by woman themselves, among which one was stored in DCM preservative solution (called "liquid sample") and the other was applied on the Whatman Indicating FTA Elute® card (FTA card). Another two samples were collected by physician and stored in DCM preservative solution and FTA card, respectively. All the samples were detected by careHPV™ test. All the women were administered a colposcopy examination, and biopsies were taken for pathological confirmation if necessary. FTA card demonstrated a comparable sensitivity of detecting high grade Cervical Intraepithelial Neoplasia (CIN) with the liquid sample carrier for self and physician-sampling, but showed a higher specificity than that of liquid sample carrier for self-sampling (FTA vs Liquid: 79.0% vs 71.6%, p=0.02). Generally, the FTA card had a comparable accuracy with that of Liquid-based medium by different sampling operators, with an area under the curve of 0.807 for physician and FTA, 0.781 for physician and Liquid, 0.728 for self and FTA, and 0.733 for self and Liquid (p>0.05). FTA card is a promising sample carrier for cervical cancer screening. With appropriate education programmes and further optimization of the experimental workflow, FTA card based self-collection in combination with centralized careHPV™ testing can help expand the coverage of cervical cancer screening in low-resource areas.
Abramson, Charles I; Robinson, Ellen Gray; Rice, Jessica; Burley, Jami; Bergman, Staci; Delougherty, Patricia; Reudy, Katherine
2002-06-01
We describe a template to create concept cards in psychology courses using a word processing program. Students create their own individualized cards, which have the look and feel of flashcards and retain the same self-testing and monitoring features. Students report the template is easy to use, that the cards help them focus their study behavior and employ critical thinking skills in learning class material. We offer several suggestions on how to use the cards.
Duckworth, Angela L.; Quinn, Patrick D.; Tsukayama, Eli
2013-01-01
The increasing prominence of standardized testing to assess student learning motivated the current investigation. We propose that standardized achievement test scores assess competencies determined more by intelligence than by self-control, whereas report card grades assess competencies determined more by self-control than by intelligence. In particular, we suggest that intelligence helps students learn and solve problems independent of formal instruction, whereas self-control helps students study, complete homework, and behave positively in the classroom. Two longitudinal, prospective studies of middle school students support predictions from this model. In both samples, IQ predicted changes in standardized achievement test scores over time better than did self-control, whereas self-control predicted changes in report card grades over time better than did IQ. As expected, the effect of self-control on changes in report card grades was mediated in Study 2 by teacher ratings of homework completion and classroom conduct. In a third study, ratings of middle school teachers about the content and purpose of standardized achievement tests and report card grades were consistent with the proposed model. Implications for pedagogy and public policy are discussed. PMID:24072936
76 FR 2930 - Market Test of Experimental Product: “Gift Cards”
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-18
... POSTAL SERVICE Market Test of Experimental Product: ``Gift Cards'' AGENCY: Postal Service \\TM\\. ACTION: Notice. SUMMARY: The Postal Service gives notice of a market test of an experimental product in... notice pursuant to 39 U.S.C. 3641(c)(1) that it will begin a market test of its ``Gift Cards...
Design of an automatic production monitoring system on job shop manufacturing
NASA Astrophysics Data System (ADS)
Prasetyo, Hoedi; Sugiarto, Yohanes; Rosyidi, Cucuk Nur
2018-02-01
Every production process requires monitoring system, so the desired efficiency and productivity can be monitored at any time. This system is also needed in the job shop type of manufacturing which is mainly influenced by the manufacturing lead time. Processing time is one of the factors that affect the manufacturing lead time. In a conventional company, the recording of processing time is done manually by the operator on a sheet of paper. This method is prone to errors. This paper aims to overcome this problem by creating a system which is able to record and monitor the processing time automatically. The solution is realized by utilizing electric current sensor, barcode, RFID, wireless network and windows-based application. An automatic monitoring device is attached to the production machine. It is equipped with a touch screen-LCD so that the operator can use it easily. Operator identity is recorded through RFID which is embedded in his ID card. The workpiece data are collected from the database by scanning the barcode listed on its monitoring sheet. A sensor is mounted on the machine to measure the actual machining time. The system's outputs are actual processing time and machine's capacity information. This system is connected wirelessly to a workshop planning application belongs to the firm. Test results indicated that all functions of the system can run properly. This system successfully enables supervisors, PPIC or higher level management staffs to monitor the processing time quickly with a better accuracy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
SMITH, S.G.
1999-10-21
The following Acceptance Test Procedure was written to test the ENRAF series 854 ATG with SPU II card prior to installation in the Tank Farms. The procedure sets various parameters and verifies the gauge and alarms functionality.
Detection of Gastrointestinal Pathogens from Stool Samples on Hemoccult Cards by Multiplex PCR.
Alberer, Martin; Schlenker, Nicklas; Bauer, Malkin; Helfrich, Kerstin; Mengele, Carolin; Löscher, Thomas; Nothdurft, Hans Dieter; Bretzel, Gisela; Beissner, Marcus
2017-01-01
Purpose . Up to 30% of international travelers are affected by travelers' diarrhea (TD). Reliable data on the etiology of TD is lacking. Sufficient laboratory capacity at travel destinations is often unavailable and transporting conventional stool samples to the home country is inconvenient. We evaluated the use of Hemoccult cards for stool sampling combined with a multiplex PCR for the detection of model viral, bacterial, and protozoal TD pathogens. Methods . Following the creation of serial dilutions for each model pathogen, last positive dilution steps (LPDs) and thereof calculated last positive sample concentrations (LPCs) were compared between conventional stool samples and card samples. Furthermore, card samples were tested after a prolonged time interval simulating storage during a travel duration of up to 6 weeks. Results . The LPDs/LPCs were comparable to testing of conventional stool samples. After storage on Hemoccult cards, the recovery rate was 97.6% for C. jejuni , 100% for E . histolytica , 97.6% for norovirus GI, and 100% for GII. Detection of expected pathogens was possible at weekly intervals up to 42 days. Conclusion . Stool samples on Hemoccult cards stored at room temperature can be used in combination with a multiplex PCR as a reliable tool for testing of TD pathogens.
Sánchez, Juan Luis; Martín, Javier; López, Carolina
2017-12-01
The classic version of the Wisconsin Card Sorting Test (WCST) consists of correctly sorting 128 cards according to changing sorting criteria. Its application is costly in terms of the time employed, with all the negative consequences this entails (decrease in motivation, frustration, and fatigue). The main objective of this study was to test the usefulness of the shortened version of the WCST as compared to the full test by analyzing the equivalence between the two decks comprising the full 128-card version on a sample of patients diagnosed with sporadic late onset Alzheimer disease (SLOAD) and to check its clinical usefulness. The variables showed equivalence between the two decks and their ability to differentiate between the control group (CG) and the Alzheimer disease (AD) group. The scores obtained suggest equivalence between decks and that the application of only the first deck is sufficient.
NASA Technical Reports Server (NTRS)
Skweres, Joyce A.; Bassinger, Virginia J.; Mishra, S. K.; Pierson, Duane L.
1992-01-01
Reference cultures of 16 microorganisms obtained from the American Type Culture Collection and four clinical isolates were used in standardized solutions to inoculate 60 cards for each test strain. A set of three ID and three susceptibility cards was processed in the Vitek AutoMicrobic System (AMS) immediately after inoculation. The remaining cards were refrigerated at 4 C, and sets of six cards were removed and processed periodically for up to 17 days. The preinoculated AMS cards were evaluated for microorganism identification, percent probability of correct identification, length of time required for final result, individual substrate reactions, and antibiotic minimal inhibitory/concentration (MIC) values. Results indicate that 11 of the 20 microbes tested withstood refrigerated storage up to 17 days without detectable changes in delineating characteristics. MIC results appear variable, but certain antibiotics proved to be more stable than others. The results of these exploratory studies will be used to plan a microgravity experiment designed to study the effect of microgravity on microbial physiology and antibiotic sensitivity.
Commercial Off-The-Shelf (COTS) Graphics Processing Board (GPB) Radiation Test Evaluation Report
NASA Technical Reports Server (NTRS)
Salazar, George A.; Steele, Glen F.
2013-01-01
Large round trip communications latency for deep space missions will require more onboard computational capabilities to enable the space vehicle to undertake many tasks that have traditionally been ground-based, mission control responsibilities. As a result, visual display graphics will be required to provide simpler vehicle situational awareness through graphical representations, as well as provide capabilities never before done in a space mission, such as augmented reality for in-flight maintenance or Telepresence activities. These capabilities will require graphics processors and associated support electronic components for high computational graphics processing. In an effort to understand the performance of commercial graphics card electronics operating in the expected radiation environment, a preliminary test was performed on five commercial offthe- shelf (COTS) graphics cards. This paper discusses the preliminary evaluation test results of five COTS graphics processing cards tested to the International Space Station (ISS) low earth orbit radiation environment. Three of the five graphics cards were tested to a total dose of 6000 rads (Si). The test articles, test configuration, preliminary results, and recommendations are discussed.
ERIC Educational Resources Information Center
Silver, Steven S.
FMS/3 is a system for producing hard copy documentation at high speed from free format text and command input. The system was originally written in assembler language for a 12K IBM 360 model 20 using a high speed 1403 printer with the UCS-TN chain option (upper and lower case). Input was from an IBM 2560 Multi-function Card Machine. The model 20…
An Inexpensive System for Producing Examinations with Minimal Typing and Proofreading.
ERIC Educational Resources Information Center
Mershon, Donald H.
1982-01-01
Describes a method for increasing efficiency of examination production which uses file cards to store and organize test items. The process of reproducing tests directly from master copies made with file cards is discussed. (AM)
Standiford, H C; Bernstein, D; Nipper, H C; Caplan, E; Tatem, B; Hall, J S; Reynolds, J
1981-01-01
Gentamicin levels were determined in 100 serum specimens by a new latex agglutination inhibition card test, a radioimmunoassay (RIA), and a bioassay. Correlation coefficients determined by linear regression analysis demonstrated that the levels obtained by the latex agglutination inhibition card test had a high degree of correlation with the RIA and could be performed much faster and more economically when processing small numbers of specimens. The bioassay had a slightly lower degree of correlation with both the RIA and the latex test and was adversely influenced by concurrently administered antibiotics which could not be eliminated by beta-lactamase. When measuring gentamicin concentrations above 2 micrograms/ml, the coefficient of variation was less than 14% for the latex agglutination assay compared with 15% for the bioassay and 12% for RIA. The latex agglutination inhibition card test is a rapid, accurate, specific, and reproducible method for monitoring gentamicin levels in patients and is particularly applicable for laboratories processing small numbers of specimens. PMID:7247384
Mancardi, G L; Uccelli, M M; Sonnati, M; Comi, G; Milanese, C; De Vincentiis, A; Battaglia, M A
2000-04-01
The SMile Card was developed as a means for computerising clinical information for the purpose of transferability, accessibility, standardisation and compilation of a national database of demographic and clinical information about multiple sclerosis (MS) patients. In many European countries, centres for MS are organised independently from one another making collaboration, consultation and patient referral complicated. Only the more highly advanced clinical centres, generally located in large urban areas, have had the possibility to utilise technical possibilities for improving the organisation of patient clinical and research information, although independently from other centres. The information system, developed utilising the Visual Basic language for Microsoft Windows 95, stores information via a 'smart card' in a database which is initiated and updated utilising a microprocessor, located at each neurological clinic. The SMile Card, currently being tested in Italy, permits patients to carry with them all relevant medical information without limitations. Neurologists are able to access and update, via the microprocessor, the patient's entire medical history and MS-related information, including the complete neurological examination and laboratory test results. The SMile Card provides MS patients and neurologists with a complete computerised archive of clinical information which is accessible throughout the country. In addition, data from the SMile Card system can be exported to other database programs.
Hopkins, D R; Florez, D
1977-08-01
A small study comparing results of the rapid plasma reagin (RPR) teardrop card test performed in the field, with results of Venereal Disease Research Laboratory (VDRL) and fluorescent treponemal antibody absorption (FTA-ABS) tests performed in the laboratory on venous blood specimens from the same suspected yaws patients was undertaken in Columbia in July 1975. The results suggest that the RPR teardrop card test may be used to screen for infectious, or potentially infectious, yaws patients under field conditions, but that it will not reliably detect patients with VDRL titres of 1:2 or less, or all patients in whom sera are reactive in the FTA-ABS test.
Hopkins, D R; Florez, D
1977-01-01
A small study comparing results of the rapid plasma reagin (RPR) teardrop card test performed in the field, with results of Venereal Disease Research Laboratory (VDRL) and fluorescent treponemal antibody absorption (FTA-ABS) tests performed in the laboratory on venous blood specimens from the same suspected yaws patients was undertaken in Columbia in July 1975. The results suggest that the RPR teardrop card test may be used to screen for infectious, or potentially infectious, yaws patients under field conditions, but that it will not reliably detect patients with VDRL titres of 1:2 or less, or all patients in whom sera are reactive in the FTA-ABS test. PMID:336143
Flies, Emily J; Toi, Cheryl; Weinstein, Philip; Doggett, Stephen L; Williams, Craig R
2015-07-01
Spatially and temporally accurate information about infectious mosquito distribution allows for pre-emptive public health interventions that can reduce the burden of mosquito-borne infections on human populations. However, the labile nature of arboviruses, the low prevalence of infection in mosquitoes, the expensive labor costs for mosquito identification and sorting, and the specialized equipment required for arbovirus testing can obstruct arbovirus surveillance efforts. The recently developed techniques of testing mosquito expectorate using honey-baited nucleic acid preservation cards or sugar bait stations allows a sensitive method of testing for infectious, rather than infected, mosquito vectors. Here we report the results from the first large-scale incorporation of honey-baited cards into an existing mosquito surveillance program. During 4 months of the peak virus season (January-April, 2014) for a total of 577 trap nights, we set CO2-baited encephalitis vector survey (EVS) light traps at 88 locations in South Australia. The collection container for the EVS trap was modified to allow for the placement of a honey-baited nucleic acid preservation card (FTA™ card) inside. After collection, mosquitoes were maintained in a humid environment and allowed access to the cards for 1 week. Cards were then analyzed for common endemic Australian arboviruses using a nested RT-PCR. Eighteen virus detections, including 11 Ross River virus, four Barmah Forest virus, and three Stratford virus (not previously reported from South Australia) were obtained. Our findings suggest that adding FTA cards to an existing mosquito surveillance program is a rapid and efficient way of detecting infectious mosquitoes with high spatial resolution.
NASA Technical Reports Server (NTRS)
Jorgensen, James H.; Skweres, Joyce A.; Mishra S. K.; McElmeel, M. Letticia; Maher, Louise A.; Mulder, Ross; Lancaster, Michael V.; Pierson, Duane L.
1997-01-01
Very little is known regarding the affects of the microgravity environment of space flight upon the action of antimicrobial agents on bacterial pathogens. This study was undertaken to develop a simple method for conducting antibacterial susceptibility tests during a Space Shuttle mission. Specially prepared susceptibility test research cards (bioMerieux Vitek, Hazelwood, MO) were designed to include 6-11 serial two-fold dilutions of 14 antimicrobial agents, including penicillins, cephalosporins, a Beta-lactamase inhibitor, vancomycin, erythromycin, tetracycline, gentamicin, ciprofloxacin, and trimethoprim/sulfamethoxazole. Minimal inhibitory concentrations (MICS) of the drugs were determined by visual reading of color endpoints in the Vitek research cards made possible by incorporation of a colorimetric growth indicator (alamarBlue(Trademark), Accumed International, Westlake, OH). This study has demonstrated reproducible susceptibility results when testing isolates of Staphylococcus aurezis, Group A Streptococcus, Enterococcusfaecalis, Escherichia coli (beta-lactamase positive and negative strains), Klebsiella pneumoniae, Enterobacter cloacae, and Pseudomoiias aeruginosa. In some instances, the MICs were comparable to those determined using a standard broth microdilution method, while in some cases the unique test media and format yielded slightly different values, that were themselves reproducible. The proposed in-flight experiment will include inoculation of the Vitek cards on the ground prior to launch of the Space Shuttle, storage of inoculated cards at refrigeration temperature aboard the Space Shuttle until experiment initiation, then incubation of the cards for 18-48 h prior to visual interpretation of MICs by the mission's astronauts. Ground-based studies have shown reproducible MICs following storage of inoculated cards for 7 days at 4-8 C to accommodate the mission's time schedule and the astronauts' activities. For comparison, ground-based control (normal gravity) MIC values will be generated by simultaneous inoculation and incubation of a second set of test cards in a laboratory at the launch site. This procedure can provide a safe and compact experiment that should yield new information on the affects of microgravity on the biological activities of various classes of antibiotics.
Material fatigue data obtained by card-programmed hydraulic loading system
NASA Technical Reports Server (NTRS)
Davis, W. T.
1967-01-01
Fatigue tests using load distributions from actual loading histories encountered in flight are programmed on punched electronic accounting machine cards. With this hydraulic loading system, airframe designers can apply up to 55 load levels to a test specimen.
Discount medical cards: innovation or illusion?
Kofman, Mila; Libster, Jennifer; Bangit, Eliza
2005-03-01
Discount medical cards have come under increasing scrutiny by regulators and law enforcement officials as a result of mounting consumer-reported problems. For their study, the authors tested five cards available in the Washington, D.C., metro area; interviewed card company representatives, state attorneys general insurance regulators, and insurance agents; and reviewed court and administrative actions. While some cards provide a measure of value, other cards were found to have serious drawbacks, including: high-pressure sales tactics; misleading or inaccurate promotion; exaggerated claims of savings; difficulty finding participating doctors; and providers who failed to give cardholders promised discounts. Some discount card companies are seeking to reform the market through a trade association and voluntary code of conduct. Still, legislative and regulatory interventions will be needed to protect consumers in an unregulated and growing market.
Gutierrez, Arnel F.
2014-01-01
The complex concepts and vocabulary of biology classes discourage many students. In this study, a pretest–posttest model was used to test the effectiveness of an educational card game in reinforcing biological concepts in comparison with traditional teaching methods. The subjects of this study were two biology classes at Bulacan State University–Sarmiento Campus. Both classes received conventional instruction; however, the experimental group's instruction was supplemented with the card game, while the control group's instruction was reinforced with traditional exercises and assignments. The score increases from pretest to posttest showed that both methods effectively reinforced biological concepts, but a t test showed that the card game is more effective than traditional teaching methods. Additionally, students from the experimental group evaluated the card game using five criteria: goals, design, organization, playability, and usefulness. The students rated the material very satisfactory. PMID:24591506
Gutierrez, Arnel F
2014-01-01
The complex concepts and vocabulary of biology classes discourage many students. In this study, a pretest-posttest model was used to test the effectiveness of an educational card game in reinforcing biological concepts in comparison with traditional teaching methods. The subjects of this study were two biology classes at Bulacan State University-Sarmiento Campus. Both classes received conventional instruction; however, the experimental group's instruction was supplemented with the card game, while the control group's instruction was reinforced with traditional exercises and assignments. The score increases from pretest to posttest showed that both methods effectively reinforced biological concepts, but a t test showed that the card game is more effective than traditional teaching methods. Additionally, students from the experimental group evaluated the card game using five criteria: goals, design, organization, playability, and usefulness. The students rated the material very satisfactory.
Detection of Gastrointestinal Pathogens from Stool Samples on Hemoccult Cards by Multiplex PCR
Schlenker, Nicklas; Bauer, Malkin; Helfrich, Kerstin; Mengele, Carolin; Löscher, Thomas; Nothdurft, Hans Dieter; Bretzel, Gisela; Beissner, Marcus
2017-01-01
Purpose. Up to 30% of international travelers are affected by travelers' diarrhea (TD). Reliable data on the etiology of TD is lacking. Sufficient laboratory capacity at travel destinations is often unavailable and transporting conventional stool samples to the home country is inconvenient. We evaluated the use of Hemoccult cards for stool sampling combined with a multiplex PCR for the detection of model viral, bacterial, and protozoal TD pathogens. Methods. Following the creation of serial dilutions for each model pathogen, last positive dilution steps (LPDs) and thereof calculated last positive sample concentrations (LPCs) were compared between conventional stool samples and card samples. Furthermore, card samples were tested after a prolonged time interval simulating storage during a travel duration of up to 6 weeks. Results. The LPDs/LPCs were comparable to testing of conventional stool samples. After storage on Hemoccult cards, the recovery rate was 97.6% for C. jejuni, 100% for E. histolytica, 97.6% for norovirus GI, and 100% for GII. Detection of expected pathogens was possible at weekly intervals up to 42 days. Conclusion. Stool samples on Hemoccult cards stored at room temperature can be used in combination with a multiplex PCR as a reliable tool for testing of TD pathogens. PMID:28408937
NASA Astrophysics Data System (ADS)
Prejean-Harris, Rose M.
Over the last decade, accountability has been the driving force for many changes in education in the United States. One major educational reform effort is the standards-based movement with a focus of combining a number of processes that involve aligning curriculum, instruction, assessment and feedback to specific standards that are measureable and indicative of student achievement. The purpose of this study is to determine if the type of report card is a possible predictor of third grade student achievement on standardized tests in mathematics and science for the 2012 Criterion-Referenced Competency Test (CRCT). The results of this study concluded that the difference in test scores in mathematics and science for students in the traditional report card group was not statistically significant when compared to the scores of students in the standards-based report card group when controlling for poverty level, school locale, and school district. However, students in the traditional report card group scored an average of 1.01 point higher in mathematics and 2.27 points higher in science than students in the standards-based report card group.
Clinical evaluation of the Vitek ANI card for identification of anaerobic bacteria.
Schreckenberger, P C; Celig, D M; Janda, W M
1988-01-01
An evaluation of the Vitek Anaerobe Identification (ANI) card was performed with 341 bacterial isolates, including 313 clinical isolates and 28 stock strains of anaerobic microorganisms. Identifications obtained with the ANI card were compared with those determined by conventional methods. The card identified 73.2% of 149 anaerobic gram-negative bacilli, 63.6% of 44 Clostridium spp., 65.8% of 38 anaerobic nonsporeforming gram-positive bacilli, and 69.1% of 110 anaerobic cocci, with no further testing required. When genus-level identifications were included, 83.9% of the anaerobic gram-negative bacilli, 70.5% of Clostridium spp., 73.7% of the anaerobic nonsporeforming gram-positive bacilli, and 73.6% of the anaerobic cocci were identified. Nineteen isolates (5.6%) produced identifications of good confidence but marginal separation or questionable biotype, in which the correct identification was listed with one or two other possible choices and extra tests were required and suggested. A total of 28 (8.2%) were not identified and 29 isolates (8.5%) were misidentified by the ANI card. Among the commonly isolated clinically significant anaerobes, the ANI card identified 100% of 55 Bacteroides fragilis and 100% of 8 Clostridium perfringens. Use of supplemental tests and expansion of the data base to include additional strains of organisms that are difficult to separate even with conventional methods may improve the accuracy of the ANI card as a method for identification of anaerobic bacteria in the clinical laboratory. PMID:3343321
Shank, Russell
1965-01-01
Recent trends in indexing emphasize mechanical, not intellectual, developments. Mechanized operations have produced indexes in depth (1) of information on limited areas of science or (2) utilizing limited parameters for analysis. These indexes may include only citations or both useful data and citations of source literature. Both keyword-in-context and citation indexing seem to be passing the test of the marketplace. Mechanical equipment has also been successfully used to manipulate EAM cards for production of index copy. Information centers are increasingly being used as control devices in narrowly defined subject areas. Authors meet growing pressures to participate in information control work by preparing abstracts of their own articles. Mechanized image systems persist, although large systems are scarce and the many small systems may bring only limited relief for information control and retrieval problems. Experimentation and limited development continue on theory and technique of automatic indexing and abstracting. PMID:14306025
Raina, Abhay; Hennessy, Ricky; Rains, Michael; Allred, James; Hirshburg, Jason M; Diven, Dayna; Markey, Mia K.
2016-01-01
Background Traditional metrics for evaluating the severity of psoriasis are subjective, which complicates efforts to measure effective treatments in clinical trials. Methods We collected images of psoriasis plaques and calibrated the coloration of the images according to an included color card. Features were extracted from the images and used to train a linear discriminant analysis classifier with cross-validation to automatically classify the degree of erythema. The results were tested against numerical scores obtained by a panel of dermatologists using a standard rating system. Results Quantitative measures of erythema based on the digital color images showed good agreement with subjective assessment of erythema severity (κ = 0.4203). The color calibration process improved the agreement from κ = 0.2364 to κ = 0.4203. Conclusions We propose a method for the objective measurement of the psoriasis severity parameter of erythema and show that the calibration process improved the results. PMID:26517973
Design and realization of an automatic weather station at island
NASA Astrophysics Data System (ADS)
Chen, Yong-hua; Li, Si-ren
2011-10-01
In this paper, the design and development of an automatic weather station monitoring is described. The proposed system consists of a set of sensors for measuring meteorological parameters (temperature, wind speed & direction, rain fall, visibility, etc.). To increase the reliability of the system, wind speed & direction are measured redundantly with duplicate sensors. The sensor signals are collected by the data logger CR1000 at several analog and digital inputs. The CR1000 and the sensors form a completely autonomous system which works with the other systems installed in the container. Communication with the master PC is accomplished over the method of Code Division Multiple Access (CDMA) with the Compact Caimore6550P CDMA DTU. The data are finally stored in tables on the CPU as well as on the CF-Card. The weather station was built as an efficient autonomous system which operates with the other systems to provide the required data for a fully automatic measurement system.
Document cards: a top trumps visualization for documents.
Strobelt, Hendrik; Oelke, Daniela; Rohrdantz, Christian; Stoffel, Andreas; Keim, Daniel A; Deussen, Oliver
2009-01-01
Finding suitable, less space consuming views for a document's main content is crucial to provide convenient access to large document collections on display devices of different size. We present a novel compact visualization which represents the document's key semantic as a mixture of images and important key terms, similar to cards in a top trumps game. The key terms are extracted using an advanced text mining approach based on a fully automatic document structure extraction. The images and their captions are extracted using a graphical heuristic and the captions are used for a semi-semantic image weighting. Furthermore, we use the image color histogram for classification and show at least one representative from each non-empty image class. The approach is demonstrated for the IEEE InfoVis publications of a complete year. The method can easily be applied to other publication collections and sets of documents which contain images.
1994-09-01
650 B.C. in Asia Minor, coins were developed and used in acquiring goods and services. In France, during the eighteenth century, paper money made its... counterfeited . [INFO94, p. 23] Other weaknesses of bar code technology include limited data storage capability based on the bar code symbology used when...extremely accurate, with calculated error rates as low as 1 in 100 trillion, and are difficult to counterfeit . Strong magnetic fields cannot erase RF
FT 3 Flight Test Cards for Export
NASA Technical Reports Server (NTRS)
Marston, Michael L.
2015-01-01
These flight test cards will be made available to stakeholders who participated in FT3. NASA entered into the relationship with our stakeholders, including the FAA, to develop requirements that will lead to routine flights of unmanned aircraft systems flying in the national airspace system.
Assessing Semantic Knowledge Using Computer-Based and Paper-Based Media
1992-01-01
capitalized upon in this research. Computer-Based Assessment A computer-based game or test, FlashCards (Liggett & Federico, 1986), was adopt- ed and adapted...alterative forms did not have to be specifically or previously programmed as such. FlashCards is analogous to using real flash cards. That is, a...reflects their degree of confidence in their answer. Also, for each answer the student’s response latency is recorded and displayed. FlashCards quizzed
Eye movements during the Rorschach test in schizophrenia.
Hori, Yasuko; Fukuzako, Hiroshi; Sugimoto, Yoko; Takigawa, Morikuni
2002-08-01
In order to understand relationships between scanning behaviors, characteristics of visual stimuli and the clinical symptoms in schizophrenia, eye movements of 37 schizophrenic patients and 36 controls were recorded using an eye-mark recorder during a free-response period in a Rorschach test. Four cards (I, II, V and VIII) were used. Data were analyzed during 15 s from the presentation of each card. For all cards, the number of eye fixations and the number of eye fixation areas were fewer, and total scanning length and mean scanning length were shorter for schizophrenic patients than for controls. For card II, in the non-popular response group, eye fixation frequency upon area 5 + 6 (red) was higher for schizophrenic patients. For card VIII, in the popular response group, eye fixation frequency upon area 5 + 6 (pink) was lower for schizophrenic patients. For cards II and VIII, the number of eye fixations was inversely correlated with negative symptoms. For card II, total scanning length tended to be inversely correlated with negative symptoms, and mean eye fixation time was correlated with negative symptoms. The number of eye fixation areas was inversely correlated with positive symptoms. For card VIII, eye fixation frequency in a stimulative area tended to be correlated with positive symptoms. Scanning behaviors in schizophrenic patients are affected by characteristics of visual stimuli, and partially by clinical symptoms.
ERIC Educational Resources Information Center
Horowitz-Kraus, Tzipi
2014-01-01
Adolescents with dyslexia exhibit well-established impairments in executive abilities. The Wisconsin card sorting test (WCST) is an executive test that yields surprisingly inconsistent results with this population. The current study aimed to shed light on the contradictory findings in the literature regarding the performance levels by individuals…
ERIC Educational Resources Information Center
Paladino, Emily B.; Klentzin, Jacqueline C.; Mills, Chloe P.
2017-01-01
Based on in-person, task-based usability testing and interviews, the authors' library Web site was recently overhauled in order to improve user experience. This led to the authors' interest in additional usability testing methods and test environments that would most closely fit their library's goals and situation. The appeal of card sorting…
AUTOMATIC CALIBRATING SYSTEM FOR PRESSURE TRANSDUCERS
Amonette, E.L.; Rodgers, G.W.
1958-01-01
An automatic system for calibrating a number of pressure transducers is described. The disclosed embodiment of the invention uses a mercurial manometer to measure the air pressure applied to the transducer. A servo system follows the top of the mercury column as the pressure is changed and operates an analog- to-digital converter This converter furnishes electrical pulses, each representing an increment of pressure change, to a reversible counterThe transducer furnishes a signal at each calibration point, causing an electric typewriter and a card-punch machine to record the pressure at the instant as indicated by the counter. Another counter keeps track of the calibration points so that a number identifying each point is recorded with the corresponding pressure. A special relay control system controls the pressure trend and programs the sequential calibration of several transducers.
Beta Testing an Oral Health Edutainment Card Game Among 12-13-Year-Old Children in Bangalore, India.
Harikiran, Arkalgud Govindraju; Vadavi, Deepti; Shruti, Tulika
2017-12-01
Card games are easy, cost effective, culturally acceptable, as well as sustainable and require minimal infrastructure over other edutainment approaches in achieving health and oral health promotion goals. Therefore, we wanted to conceptualize, develop, and beta test an innovative oral health edutainment card game for preadolescent children in Bangalore, India. An innovative oral health card game, titled "32 warriors" was conceptualized and developed to incorporate age appropriate, medically accurate oral health information. The card game aimed at empowering children to take appropriate care of their oral health. The card game was beta tested on 45 children, aged between 12 and 13 years. Using prepost design, a 32-itemed, closed-ended questionnaire assessed children's oral health knowledge, attitude, and feedback on the game. Change in mean scores for knowledge and attitude was assessed using "Wilcoxon Sign Rank test" at P < 0.05. "Effect size" was calculated. Feedback was categorized in terms of type of response and its frequency. Statistically significant improvement was observed in group mean overall score, mean knowledge, and attitude scores, respectively (pre 14.7 ± 2.91 and post 18.6 ± 4.35, P = 0.003; 11.8 ± 2.73, 14.76 ± 4.0, P = 0.000; 2.93 ± 1.09, 3.84 ± 1.02, P = 0.000), with mean effect size 0.5. Participants reported that they enjoyed the game and learned new things about oral health. The card game is appealing to children and improves their oral health knowledge and attitude as evidenced by beta test results. We need to further explore the demand, feasibility, and cost effectiveness of introducing this game in formal settings (school based)/informal settings (family and other social settings).
Vasseur, Francis; Sendid, Boualem; Broly, Franck; Gower-Rousseau, Corinne; Sarazin, Aurore; Standaert-Vitse, Annie; Colombel, Jean-Frederic; Poulain, Daniel; Jouault, Thierry
2013-03-18
Crohn's disease (CD) is associated with elevated anti-glycans antibody response in 60% of CD patients, and 25% of healthy first-degree relatives (HFDRs), suggesting a genetic influence for this humoral response. In mice, anti-glucan antibody response depends on the NLRP3 inflammasome. Here, we explored the effect of mutated CARD8, a component of the inflammasome, on anti-glycans antibody response in human. The association between p.C10X mutation (rs2043211) of the CARD8 gene and the levels of anti-glycans antibody response was examined in 39 CD families. The family-based QTDT association test was used to test for the genetic association between CARD8 p.C10X mutation and anti-glycan antibodies in the pedigrees. The difference in antibody responses determined by ELISA was tested in a subgroup of CD probands (one per family) and in a subgroup of HFDRs using the Wilcoxon Kruskal Wallis non-parametric test. The QTDT familial transmission tests showed that the p.C10X mutation of CARD8 was significantly associated with lower levels of antibody to mannans and glucans but not chitin (p=0.024, p=0.0028 and p=0.577, for ASCA, ALCA and ACCA, respectively). These associations were independent of NOD2 and NOD1 genetic backgrounds. The p.C10X mutation significantly associated or displayed a trend toward lower ASCA and ALCA levels (p=0.038 and p=0.08, respectively) only in the subgroup of CD probands. Such associations were not significant for ACCA levels in both subgroups of CD probands and of HFDRs. Our results show that ASCA and ALCA but not ACCA levels are under the influence of CARD8 genotype. Alteration of CARD8, a component of inflammasome, is associated with lower levels of antibodies directed to mannans and glucans at least in CD patients.
The Department of Veterans Affairs Optical Patient Card Workstation.
Gomez, E.; Demetriades, J. E.; Babcock, D.; Peterson, J.
1991-01-01
The Department of Veterans Affairs has developed an optical patient card application which will undergo alpha testing in 1991. The optical cards are carried by patients and contain administrative, clinical, and image information. An optical patient card workstation (OPCW) will read/write these cards and pass this information to the VA Decentralized Hospital Computer Program (DHCP), the VA's health care information system. The intent of this work is to study the potential benefits of this technology to the VA's distributed health care network, with a large mobile patient population. It is hoped that the use of optical cards and the OPCW will enhance clinicians ability to work with a timely composite health record, and expedite the administrative workload of the medical center. PMID:1807626
The Department of Veterans Affairs Optical Patient Card Workstation.
Gomez, E; Demetriades, J E; Babcock, D; Peterson, J
1991-01-01
The Department of Veterans Affairs has developed an optical patient card application which will undergo alpha testing in 1991. The optical cards are carried by patients and contain administrative, clinical, and image information. An optical patient card workstation (OPCW) will read/write these cards and pass this information to the VA Decentralized Hospital Computer Program (DHCP), the VA's health care information system. The intent of this work is to study the potential benefits of this technology to the VA's distributed health care network, with a large mobile patient population. It is hoped that the use of optical cards and the OPCW will enhance clinicians ability to work with a timely composite health record, and expedite the administrative workload of the medical center.
Application of an artificial neural network to pump card diagnosis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ashenayi, K.; Lea, J.F.; Kemp, F.
1994-12-01
Beam pumping is the most frequently used artificial-lift technique for oil production. Downhole pump cards are used to evaluate performance of the pumping unit. Pump cards can be generated from surface dynamometer cards using a 1D wave equation with viscous damping, as suggested by Gibbs and Neely. Pump cards contain significant information describing the behavior of the pump. However, interpretation of these cards is tedious and time-consuming; hence, an automated system capable of interpreting these cards could speed interpretation and warn of pump failures. This work presents the results of a DOS-based computer program capable of correctly classifying pump cards.more » The program uses a hybrid artificial neural network (ANN) to identify significant features of the pump card. The hybrid ANN uses classical and sinusoidal perceptrons. The network is trained using an error-back-propagation technique. The program correctly identified pump problems for more than 180 different training and test pump cards. The ANN takes a total of 80 data points as input. Sixty data points are collected from the pump card perimeter, and the remaining 20 data points represent the slope at selected points on the pump card perimeter. Pump problem conditions are grouped into 11 distinct classes. The network is capable of identifying one or more of these problem conditions for each pump card. Eight examples are presented and discussed.« less
The Effect of Labeling on Preschool Children's Performance in the Dimensional Change Card Sort Task
ERIC Educational Resources Information Center
Muller, Ulrich; Zelazo, Philip D.; Lurye, Leah E.; Liebermann, Dana P.
2008-01-01
Previous research suggests that experimenter-induced labeling of test cards improves preschoolers' performance on the Dimensional Change Card Sort Task (DCCS), a measure of flexible rule use. Three experiments attempted to further clarify how labeling aids performance on the DCCS. Experiment 1 examined the nature of the labeling effect but failed…
Disentangling Dimensions in the Dimensional Change Card-Sorting Task
ERIC Educational Resources Information Center
Kloo, Daniela; Perner, Josef
2005-01-01
The dimensional change card-sorting task (DCCS task) is frequently used to assess young children's executive abilities. However, the source of children's difficulty with this task is still under debate. In the standard DCCS task, children have to sort, for example, test cards with a red cherry or a blue banana into two boxes marked with target…
The Michigan Context and Performance Report Card: Public Elementary & Middle Schools, 2013
ERIC Educational Resources Information Center
Spalding, Audrey
2013-01-01
The Michigan Context and Performance Report Card measures school performance by adjusting standardized test scores to account for student background. Comparing schools using unadjusted test scores ignores the significant relationship between academic performance and student socioeconomic background--a dynamic outside a school's control. The…
ERIC Educational Resources Information Center
Duckworth, Angela L.; Quinn, Patrick D.; Tsukayama, Eli
2012-01-01
The increasing prominence of standardized testing to assess student learning motivated the current investigation. We propose that standardized achievement test scores assess competencies determined more by intelligence than by self-control, whereas report card grades assess competencies determined more by self-control than by intelligence. In…
Stream processing health card application.
Polat, Seda; Gündem, Taflan Imre
2012-10-01
In this paper, we propose a data stream management system embedded to a smart card for handling and storing user specific summaries of streaming data coming from medical sensor measurements and/or other medical measurements. The data stream management system that we propose for a health card can handle the stream data rates of commonly known medical devices and sensors. It incorporates a type of context awareness feature that acts according to user specific information. The proposed system is cheap and provides security for private data by enhancing the capabilities of smart health cards. The stream data management system is tested on a real smart card using both synthetic and real data.
2002-09-01
employed by the supermarket industry in 1973. Other common linear bar code symbologies are Code 39, pioneered by the defense and automotive industries...Teller Machine ( ATM ) cards are one of the prominent uses of this technology, but to a lesser extent, the technology has been used for shop floor...additional power is transmitted to it through the probe, extending its charge. There is a risk of data loss if the CMB is not accessed from time to time
Wang, Wen-Bin; Li, Jang-Yuan; Wu, Qi-Jun
2007-01-01
A LabVIEW-based self-constructed chemical virtual instrument (VI) has been developed for determining temperatures and pressures. It can be put together easily and quickly by selecting hardware modules, such as the PCI-DAQ card or serial port method, different kinds of sensors, signal-conditioning circuits or finished chemical instruments, and software modules such as data acquisition, saving, proceeding. The VI system provides individual and extremely flexible solutions for automatic measurements in physical chemistry research.
Wang, Wen-Bin; Li, Jang-Yuan; Wu, Qi-Jun
2007-01-01
A LabVIEW-based self-constructed chemical virtual instrument (VI) has been developed for determining temperatures and pressures. It can be put together easily and quickly by selecting hardware modules, such as the PCI-DAQ card or serial port method, different kinds of sensors, signal-conditioning circuits or finished chemical instruments, and software modules such as data acquisition, saving, proceeding. The VI system provides individual and extremely flexible solutions for automatic measurements in physical chemistry research. PMID:17671611
Spirituality as a predictive factor for signing an organ donor card.
Bortz, Anat Peles; Ashkenazi, Tamar; Melnikov, Semyon
2015-01-01
To examine differences in spirituality, purpose in life, and attitudes toward organ donation between people who signed and those who did not sign an organ donor card. A descriptive cross-sectional survey conducted in Israel with a sample of 312 respondents from the general population, of whom 220 (70.5%) signed an organ donor card. Data were collected during April-June 2013. Participants completed a paper questionnaire and a Web-based questionnaire consisting of four sections: spiritual health, purpose in life, attitudes toward organ donation, and social-demographic questions. Descriptive statistics, t test, chi-square test, and a logistic regression analysis were performed. Differences in mean scores between respondents who signed an organ donor card and those who did not were indicated in transcendental spirituality (p < .01), purpose in life (p < .05), and attitudes toward organ donation (p < .01). No statistically significant difference was found between the groups in the overall spirituality mean score. The spiritual transcendental dimension, individual's purpose in life, and attitudes toward organ donation explained 34.3% of the variance of signing an organ donor card. Signing an organ donor card was found to be correlated with high purpose in life, positive attitudes toward organ donation, and low level of transcendental spirituality. Nurses should assess the patient's spiritual needs in order to construct appropriate programs for promoting signing an organ donor card. Nurses who signed an organ donor card should be encouraged to share this information with their patients. © 2014 Sigma Theta Tau International.
Mohan, Kathleen M; Miller, Joseph M; Harvey, Erin M; Gerhart, Kimberly D; Apple, Howard P; Apple, Deborah; Smith, Jordana M; Davis, Amy L; Leonard-Green, Tina; Campus, Irene; Dennis, Leslie K
2016-01-01
To determine if testing binocular visual acuity in infants and toddlers using the Acuity Card Procedure (ACP) with electronic grating stimuli yields clinically useful data. Participants were infants and toddlers ages 5 to 36.7 months referred by pediatricians due to failed automated vision screening. The ACP was used to test binocular grating acuity. Stimuli were presented on the Dobson Card. The Dobson Card consists of a handheld matte-black plexiglass frame with two flush-mounted tablet computers and is similar in size and form to commercially available printed grating acuity testing stimuli (Teller Acuity Cards II [TACII]; Stereo Optical, Inc., Chicago, IL). On each trial, one tablet displayed a square-wave grating and the other displayed a luminance-matched uniform gray patch. Stimuli were roughly equivalent to the stimuli available in the printed TACII stimuli. After acuity testing, each child received a cycloplegic eye examination. Based on cycloplegic retinoscopy, patients were categorized as having high or low refractive error per American Association for Pediatric Ophthalmology and Strabismus vision screening referral criteria. Mean acuities for high and low refractive error groups were compared using analysis of covariance, controlling for age. Mean visual acuity was significantly poorer in children with high refractive error than in those with low refractive error (P = .015). Electronic stimuli presented using the ACP can yield clinically useful measurements of grating acuity in infants and toddlers. Further research is needed to determine the optimal conditions and procedures for obtaining accurate and clinically useful automated measurements of visual acuity in infants and toddlers. Copyright 2016, SLACK Incorporated.
NASA Astrophysics Data System (ADS)
Jose, Abin; Haak, Daniel; Jonas, Stephan; Brandenburg, Vincent; Deserno, Thomas M.
2015-03-01
Photographic documentation and image-based wound assessment is frequently performed in medical diagnostics, patient care, and clinical research. To support quantitative assessment, photographic imaging is based on expensive and high-quality hardware and still needs appropriate registration and calibration. Using inexpensive consumer hardware such as smartphone-integrated cameras, calibration of geometry, color, and contrast is challenging. Some methods involve color calibration using a reference pattern such as a standard color card, which is located manually in the photographs. In this paper, we adopt the lattice detection algorithm by Park et al. from real world to medicine. At first, the algorithm extracts and clusters feature points according to their local intensity patterns. Groups of similar points are fed into a selection process, which tests for suitability as a lattice grid. The group which describes the largest probability of the meshes of a lattice is selected and from it a template for an initial lattice cell is extracted. Then, a Markov random field is modeled. Using the mean-shift belief propagation, the detection of the 2D lattice is solved iteratively as a spatial tracking problem. Least-squares geometric calibration of projective distortions and non-linear color calibration in RGB space is supported by 35 corner points of 24 color patches, respectively. The method is tested on 37 photographs taken from the German Calciphylaxis registry, where non-standardized photographic documentation is collected nationwide from all contributing trial sites. In all images, the reference card location is correctly identified. At least, 28 out of 35 lattice points were detected, outperforming the SIFT-based approach previously applied. Based on these coordinates, robust geometry and color registration is performed making the photographs comparable for quantitative analysis.
PROCESS WATER BUILDING, TRA605. CONTROL PANEL SUPPLIES STATUS INDICATORS. CARD ...
PROCESS WATER BUILDING, TRA-605. CONTROL PANEL SUPPLIES STATUS INDICATORS. CARD IN LOWER RIGHT WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION ON ORIGINAL NEGATIVE. INL NEGATIVE NO. 4219. Unknown Photographer, 2/13/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Wisconsin Card Sorting Test Performance in Children with Developmental Coordination Disorder
ERIC Educational Resources Information Center
Wuang, Yee-Pay; Su, Chwen-Yng; Su, Jui-Hsing
2011-01-01
The primary purpose of this study was to investigate and compare the executive functions measured by the Wisconsin Card Sorting Test (WCST) between children with developmental coordination disorder (DCD) and age-matched normal controls. A second purpose was to examine the relations between executive functions and school functions in DCD children.…
Plain and Rolled Images from Paired Fingerprint Cards
National Institute of Standards and Technology Data Gateway
NIST Plain and Rolled Images from Paired Fingerprint Cards (Web, free access) NIST Special Database 29 is being distributed for use in development and testing fingerprint matching systems. The data consist of 216 ten-print fingerprint card pairs with both the rolled and plains (from a bottom of the fingerprint card) scanned at 19.7 pixels per mm. A newer version of the compression/decompression software on the CDROM can be found at the website http://www.nist.gov/itl/iad/ig/nigos.cfm as part of the NBIS package.
[Evaluation of the new ImmunoCard STAT!® CGE test for the diagnosis of Amebiasis].
Formenti, F; Perandin, F; Bonafini, S; Degani, M; Bisoffi, Z
2015-08-01
For many years, microscopic examination of stool samples has been considered to be the "gold standard" for diagnosis of intestinal parasites although the Polymerase Chain Reaction (PCR) analysis is increasingly utilized due to its high accuracy. Recently, PCR has been approved by the World Health Organization as the current method of choice for the diagnosis of Entamoeba histolytica infection. In this study we evaluated a novel immunochromatographic antigen detection rapid test, ImmunoCardSTAT CGE (Meridian Bioscence, Milan, Italy), which has been proposed for the diagnosis of infections caused by Cryptosporidium parvum-Giardia intestinalis-Entamoeba histolytica. There is another rapid test with a similar name, the ImmunoCard STAT! Crypto/Giardia, but it is just for Cryptosporidium and Giardia. We aimed to compare E. histolytica results obtained from the rapid test with those of a rt-PCR for the detection of E. histolytica / E. dispar DNA. The new ImmunoCard rapid antigen detection test exhibited 88% sensitivity and 92% specificity (if assessed on rt-PCR negative samples) but showed a high proportion of cross-reaction between the pathogenic E. histolytica and the non pathogenic E. dispar.
NASA Astrophysics Data System (ADS)
Sadhasivam, Jayakumar; Alamelu, M.; Radhika, R.; Ramya, S.; Dharani, K.; Jayavel, Senthil
2017-11-01
Now a days the people's attraction towards Automated Teller Machine(ATM) has been increasing even in rural areas. As of now the security provided by all the bank is ATM pin number. Hackers know the way to easily identify the pin number and withdraw money if they haven stolen the ATM card. Also, the Automated Teller Machine is broken and the money is stolen. To overcome these disadvantages, we propose an approach “Automated Secure Tracking System” to secure and tracking the changes in ATM. In this approach, while creating the bank account, the bank should scan the iris known (a part or movement of our eye) and fingerprint of the customer. The scanning can be done with the position of the eye movements and fingerprints identified with the shortest measurements. When the card is swiped then ATM should request the pin, scan the iris and recognize the fingerprint and then allow the customer to withdraw money. If somebody tries to break the ATM an alert message is given to the nearby police station and the ATM shutter is automatically closed. This helps in avoiding the hackers who withdraw money by stealing the ATM card and also helps the government in identifying the criminals easily.
Médicarte software developed for the Quebec microprocessor health card project.
Lavoie, G; Tremblay, L; Durant, P; Papillon, M J; Bérubé, J; Fortin, J P
1995-01-01
The Quebec Patient Smart Card Project is a Provincial Government initiative under the responsibility of the Rgie de l'assurance-maladie du Québec (Quebec Health Insurance Board). Development, implementation, and assessment duties were assigned to a team from Université Laval, which in turn joined a group from the Direction de la santé publique du Bas-St-Laurent in Rimouski, where the experiment is taking place. The pilot project seeks to evaluate the use and acceptance of a microprocessor card as a way to improve the exchange of clinical information between card users and various health professionals. The card can be best described as a résumé containing information pertinent to an individual's health history. It is not a complete medical file; rather, it is a summary to be used as a starting point for a discussion between health professionals and patients. The target population is composed of persons 60 years and over, pregnant women, infants under 18 months, and the residents of a small town located in the target area, St-Fabien, regardless of age. The health professionals involved are general practitioners, specialists, pharmacists, nurses, and ambulance personnel. Participation in the project is on a voluntary basis. Each health care provider participating in the project has a personal identification number (PIN) and must use both an access card and a user card to access information. This prevents unauthorized access to a patient's card and allows the staff to sign and date information entered onto the patient card. To test the microprocessor card, we developed software based on a problem-oriented approach integrating diagnosis, investigations, treatments, and referrals. This software is not an expert system that constrains the clinician to a particular decisional algorithm. Instead, the software supports the physician in decision making. The software was developed with a graphical interface (Windows 3.1) to maximize its user friendliness. A version of the software was developed for each of the four groups of health care providers involved. In addition we designed an application to interface with existing pharmaceutical software. For practical reasons and to make it possible to differentiate between the different access profiles, the information stored on the card is divided in several blocks: Identification, Emergency, History (personal and family), Screening Tests, Vaccinations, Drug Profile, General follow-up, and some Specific follow-ups (Pregnancy, Ophthalmology, Kidney failure, Cardiology, Pediatrics, Diabetes, Pneumology, Specific parameters). Over 14,000 diagnoses and symptoms are classified with four levels of precision, the codification being based on the ICPC (International Classification for Primary Care). The software contains different applications to assist the clinician in decision making. A "Drug Advisor" helps the prescriber by detecting possible interactions between drugs, giving indications (doses) and contraindications, cautions, potential side-effects and therapeutic alternatives. There is also a prevention module providing recommendations for vaccination and periodic examinations based on the patient's age and sex. The pharmaceutical, vaccination, and screening tests data banks are updated every six months. These sections of the software are accessible to access card holders at any times, even without a patient card, and constitute in themselves an interesting clinical tool. We developed a software server (SCAM) allowing the different applications to access the data in a memory card regardless of the type of memory card used. Using a single high level command language, this server provides a standardized utilization of memory cards from various manufacturers. It ensures the compatibility of the applications using the card as a storage medium. (abstract truncated)
On-orbit observations of single event upset in Harris HM-6508 1K RAMs, reissue A
NASA Astrophysics Data System (ADS)
Blake, J. B.; Mandel, R.
1987-02-01
The Harris HM-6508 1K x 1 RAMs are part of a subsystem of a satellite in a low, polar orbit. The memory module, used in the subsystem containing the RAMs, consists of three printed circuit cards, with each card containing eight 2K byte memory hybrids, for a total of 48K bytes. Each memory hybrid contains 16 HM-6508 RAM chips. On a regular basis all but 256 bytes of the 48K bytes are examined for bit errors. Two different techniques were used for detecting bit errors. The first technique, a memory check sum, was capable of automatically detecting all single bit and some double bit errors which occurred within a page of memory. A memory page consists of 256 bytes. Memory check sum tests are performed approximately every 90 minutes. To detect a multiple error or to determine the exact location of the bit error within the page the entire contents of the memory is dumped and compared to the load file. Memory dumps are normally performed once a month, or immediately after the check sum routine detects an error. Once the exact location of the error is found, the correct value is reloaded into memory. After the memory is reloaded, the contents of the memory location in question is verified in order to determine if the error was a soft error generated by an SEU or a hard error generated by a part failure or cosmic-ray induced latchup.
Orientations of linear stone arrangements in New South Wales
NASA Astrophysics Data System (ADS)
Hamacher, Duane W.; Fuller, Robert S.; Norris, Ray P.
2012-12-01
We test the hypothesis that Aboriginal linear stone arrangements in New South Wales (NSW) are oriented to cardinal directions. We accomplish this by measuring the azimuths of stone arrangements described in site cards from the NSW Aboriginal Heritage Information Management System. We then survey a subset of these sites to test the accuracy of information recorded on the site cards. We find a preference recorded in the site cards for cardinal orientations among azimuths. The field surveys show that the site cards are reasonably accurate, but the surveyors probably did not correct for magnetic declinations. Using Monte Carlo statistics, we show that these preferred orientations did not occur by chance and that Aboriginal people deliberately aligned these arrangements to the approximate cardinal directions. We briefly explore possible reasons for these preferred orientations and highlight the need for future work.
Technical Report of the National Marrow Donor Program
2010-08-25
Marrow Toxic Agents March 01,2010 through June 30, 2010 o Government Emergency Teleco=unications Service (GETS) calling cards were tested to...validate the ability ofRITN centers and selected NMDP staff to establish telephone contact during times of high telephone line congestion and validate card ...recruitment centers, including the following: New Registry Member Exit Card which reinforces key messages regarding the commitment one has made after
Designing and Testing a Mathematics Card Game for Teaching and Learning Elementary Group Theory
ERIC Educational Resources Information Center
Galarza, Patrick
2017-01-01
This paper explores the viability and development of the first edition of the researcher's mathematical card game, Groups, as a learning tool for elementary group theory, a topic in abstract algebra. "Groups" was play-tested by six undergraduate students in late 2016 who provided feedback on "Groups" from both utility-centric…
ERIC Educational Resources Information Center
Gligorovic, Milica; Buha, Natasa
2013-01-01
Background: The ability to generate and flexibly change concepts is of great importance for the development of academic and adaptive skills. This paper analyses the conceptual reasoning ability of children with mild intellectual disability (MID) by their achievements on the Wisconsin Card Sorting Test (WCST). Method: The sample consisted of 95…
Revalidation of game for teaching blood pressure auscultatory measurement: a pilot study.
Bellan, Margarete Consorti; Alves, Vanessa Cortez; Neves, Mayza Luzia Dos Santos; Lamas, José Luiz Tatagiba
2017-01-01
To adapt a pre-existing educational game, making it specific to the teaching of blood pressure auscultatory measurement, and to apply this game in a pilot study. The original game cards were altered by the authors and submitted to content validation by six experts in the field. After redesigns, the game was applied to 30 subjects, who answered a questionnaire (pre-test and post-test) on auscultatory measurement. Data were analyzed descriptively and by the paired Student's t-test and paired Wilcoxon test. Throughout the content validation process, 17 of the 28 original cards were modified. Of these 17 cards, 13 obtained 80% agreement, and the rest were modified according to the judges' suggestions. The obtained grades significantly increased between pre- and the post-test. It was concluded that the reformulated game presented satisfactory evidence of content validity. Its use as a teaching-learning method was effective for this sample.
Signal processing for smart cards
NASA Astrophysics Data System (ADS)
Quisquater, Jean-Jacques; Samyde, David
2003-06-01
In 1998, Paul Kocher showed that when a smart card computes cryptographic algorithms, for signatures or encryption, its consumption or its radiations leak information. The keys or the secrets hidden in the card can then be recovered using a differential measurement based on the intercorrelation function. A lot of silicon manufacturers use desynchronization countermeasures to defeat power analysis. In this article we detail a new resynchronization technic. This method can be used to facilitate the use of a neural network to do the code recognition. It becomes possible to reverse engineer a software code automatically. Using data and clock separation methods, we show how to optimize the synchronization using signal processing. Then we compare these methods with watermarking methods for 1D and 2D signal. The very last watermarking detection improvements can be applied to signal processing for smart cards with very few modifications. Bayesian processing is one of the best ways to do Differential Power Analysis, and it is possible to extract a PIN code from a smart card in very few samples. So this article shows the need to continue to set up effective countermeasures for cryptographic processors. Although the idea to use advanced signal processing operators has been commonly known for a long time, no publication explains that results can be obtained. The main idea of differential measurement is to use the cross-correlation of two random variables and to repeat consumption measurements on the processor to be analyzed. We use two processors clocked at the same external frequency and computing the same data. The applications of our design are numerous. Two measurements provide the inputs of a central operator. With the most accurate operator we can improve the signal noise ratio, re-synchronize the acquisition clock with the internal one, or remove jitter. The analysis based on consumption or electromagnetic measurements can be improved using our structure. At first sight the same results can be obtained with only one smart card, but this idea is not completely true because the statistical properties of the signal are not the same. As the two smart cards are submitted to the same external noise during the measurement, it is more easy to reduce the influence of perturbations. This paper shows the importance of accurate countermeasures against differential analysis.
The performance of five different dried blood spot cards for the analysis of six immunosuppressants.
Koster, Remco A; Botma, Rixt; Greijdanus, Ben; Uges, Donald R A; Kosterink, Jos G W; Touw, Daan J; Alffenaar, Jan-Willem C
2015-01-01
The relation between hematocrit, substance concentration, extraction recovery and spot formation of tacrolimus, sirolimus, everolimus, ascomycin, temsirolimus and cyclosporin A was investigated for Whatman 31 ET CHR, Whatman FTA DMPK-C, Whatman 903, Perkin Elmer 226 and Agilent Bond Elut DMS DBS cards. We found that all DBS cards showed the same hematocrit and concentration-dependent recovery patterns for sirolimus, everolimus and temsirolimus. At high concentrations, the total hematocrit effects were much more pronounced than at low concentrations for tacrolimus, sirolimus, everolimus, ascomycin and temsirolimus. The tested card types showed differences in performance, especially at extreme concentrations and hematocrit values. It may be useful to investigate the performance of different types of DBS cards prior to analytical method validation.
Peluso, A L; Cozzolino, I; Bottiglieri, A; Lucchese, L; Di Crescenzo, R M; Langella, M; Selleri, C; Zeppa, P
2017-06-01
To evaluate and compare the DNA yield and quality extracted from lymph node fine needle cytology (FNC) samples stored on FTA cards to those cryopreserved, and to assess the immunoglobulin heavy and light chains (IGHK) and T-Cell receptor beta and gamma chains (TCRBG) PCR tests. DNA extractions were performed on FNC of 80 non-Hodgkin lymphomas (NHL), four myelomas and 56 benign reactive hyperplasias (BRH) cryopreserved and stored on FTA cards. The JAK2 gene was amplified to assess the DNA integrity and the IGHK/TCRBG clonality status was tested. IGHK monoclonality was found in 99% of B-cell NHL and 100% of myeloma. TCRBG monoclonality was found in 100% of T-cell NHL. TCRBG polyclonality was detected in 97% of B-cell NHL, 100% of myeloma and 96% of BRH. IGHK/TCRBG PCR data were confirmed by histological and/or follow-up controls. No differences were found in the DNA quality between cryopreservation and FTA cards storage methods. IGHK/TCRBG PCR of the lymphoproliferative process on FTA cards is comparable to those cryopreserved. FTA cards can be used to store lymph node FNC for further molecular investigations. © 2016 John Wiley & Sons Ltd.
Determinants affecting consumer adoption of contactless credit card: an empirical study.
Wang, Yu-Min
2008-12-01
The contactless credit card is one of the most promising technological innovations in the field of electronic payments. It provides consumers with greater control of payments, convenience, and transaction speed. However, contactless credit cards have yet to gain significant rates of adoption in the marketplace. Thus, effort must be made to identify factors affecting consumer adoption of contactless credit cards. Based on the technology acceptance model, innovation diffusion theory, and the relevant literature, seven variables (perceived usefulness, perceived ease of use, compatibility, perceived risk, trust, consumer involvement, availability of infrastructure) are proposed to help predict consumer adoption of contactless credit cards. Data collected from 312 respondents in Taiwan is tested against the proposed prediction model using the logistic regression approach. The results and implications of our study contribute to an expanded understanding of the factors that affect consumer adoption of contactless credit cards.
Using behavioral skills training and video rehearsal to teach blackjack skills.
Speelman, Ryan C; Whiting, Seth W; Dixon, Mark R
2015-09-01
A behavioral skills training procedure that consisted of video instructions, video rehearsal, and video testing was used to teach 4 recreational gamblers a specific skill in playing blackjack (sometimes called card counting). A multiple baseline design was used to evaluate intervention effects on card-counting accuracy and chips won or lost across participants. Before training, no participant counted cards accurately. Each participant completed all phases of the training protocol, counting cards fluently with 100% accuracy during changing speed criterion training exercises. Generalization probes were conducted while participants played blackjack in a mock casino following each training phase. Afterwards, all 4 participants were able to count cards while they played blackjack. In conjunction with count accuracy, total winnings were tracked to determine the monetary advantages associated with counting cards. After losing money during baseline, 3 of 4 participants won a substantial amount of money playing blackjack after the intervention. © Society for the Experimental Analysis of Behavior.
[Analysis for Discordance of Positive and Negative Blood Typing by Gel Card].
Li, Cui-Ying; Xu, Hong; Lei, Hui-Fen; Liu, Juan; Li, Xiao-Wei
2017-08-01
To explore the method of Gel card identifying ABO blood group, determine the inconsistent cause and the distribution of disease affecting factors, and put forward a method of its solutions. To collect 240 positive and negative typing-discordant blood speciments from patients examined by Gel card and send these speciments to blood type reference laboratory for examining with the classic tube method and serological test, such as salivary blood-group substance, in order to performe genotyping method when serologic test can not be determined. Among 240 positive and negative typing-discordant blood speciments from patients examined by Gel card, 107 blood speciments were positive and negative consistent examined by false agglutination test (44.58%), 133 blood specinents were discordent examined by false agglutination (55.42%), out of them, 35 cases (14.58%) with inconsistent cold agglutination test, 22 cases (9.17%) with weakened AB antigenicity, 16 cases (6.67%) with ABO subtyping, 12 cases (5.00%) with positive direct antiglobulin test, 11 cases (4.58%) with reduced or without antibodies, 11 cases (4.58%) with false aggregation caused by drugs or protein, 11 cases (4.58%) with salivary blood-type substances, 8 cases (3.33%) with non-ABO alloantibody, and 7 cases (2.92%) with allogeneic bone marrow transplantation. The distribution of disease were following: blood disease (16.83%), tumor (11.88%), and cardiopulmonary diseases (11.39%); chi-square test results indicated that the distribution significantly different. The analysis of ABO blood grouping shows a variety factors influencing positive and negative blood typing, and the Gel Card identification can produc more false positive blood types. Therefore, more attention should be paid on the high incidence diseases, such as blood disease, tumor, and cardiopulmonary disease.
The Impact of Frontal and Non-Frontal Brain Tumor Lesions on Wisconsin Card Sorting Test Performance
ERIC Educational Resources Information Center
Goldstein, B.; Obrzut, J. E.; John, C.; Ledakis, G.; Armstrong, C. L.
2004-01-01
Several lesion and imaging studies have suggested that the Wisconsin Card Sorting Test (WCST) is a measure of executive dysfunction. However, some studies have reported that this measure has poor anatomical specificity because patients with either frontal or non-frontal focal lesions exhibit similar performance. This study examined 25 frontal, 20…
ERIC Educational Resources Information Center
Okpube, Nnaemeka Michael; Anugwo, M. N.
2016-01-01
This study investigated the Card Games and Algebra tic-Tacmatics on Junior Secondary II Students' Achievement in Algebraic Expressions. Three research questions and three null hypotheses guided the study. The study adopted the pre-test, post-test control group design. A total of two hundred and forty (240) Junior Secondary School II students were…
ERIC Educational Resources Information Center
Head, Denise; Kennedy, Kristen M.; Rodrigue, Karen M.; Raz, Naftali
2009-01-01
Aging effects on the Wisconsin Card Sorting Test (WCST) are fairly well established but the mechanisms of the decline are not clearly understood. In this study, we examined the cognitive and neural mechanisms mediating age-related increases in perseveration on the WCST. MRI-based volumetry and measures of selected executive functions in…
Krishnamurthy, Vani; Satish, Suchitha; Doreswamy, Srinivasa Murthy; Vimalambike, Manjunath Gubbanna
2016-07-01
Cytological evaluation of body fluids is an important diagnostic technique. Cytocentrifuge has contributed immensely to improve the diagnostic yield of the body fluids. Cytocentrifuge requires a filter card for absorbing the cell free fluid. This is the only consumable which needs to be purchased from the manufacturer at a significant cost. To compare the cell density in cytocentrifuge preparations made from commercially available filter cards with custom made filter cards. This was a prospective analytical study undertaken in department of pathology of a tertiary care centre. A 300 GSM handmade paper with the absorbability similar to the conventional card was obtained and fashioned to suit the filter card slot of the cytospin. Thirty seven body fluids were centrifuged using both conventional and custom made filter card. The cell density was measured as number of cells per 10 high power fields. The median cell density was compared using Mann-Whitney U test. The agreement between the values was analysed using Bland Altman analysis. The median cell count per 10 High power field (HPF) with conventional card was 386 and that with custom made card was 408. The difference was not statistically significant (p = 0.66). There was no significant difference in the cell density and alteration in the morphology between the cell preparations using both the cards. Custom made filter card can be used for cytospin cell preparations of body fluids without loss of cell density or alteration in the cell morphology and at a very low cost.
Lee, Sung Won; Lee, Shin Seok; Oh, Dong Ho; Park, Dong Jin; Kim, Hyun Sook; Choi, Jung Ran; Chae, Soo Cheon; Yun, Ki Jung; Chung, Won Tae; Choe, Jung Yoon; Kim, Seong Kyu
2016-10-01
The aim of this study was to determine the association between P2X7R rs3751142 and CARD8 rs2043211 polymorphisms and gout susceptibility in male Korean subjects. This study enrolled a total of 242 male patients with gout and 280 healthy controls. The polymorphisms of two individual genes including rs3751142(C>A) in the P2X7R gene and rs2043211(A>T) in the CARD8 gene were assessed using Taq-Man analysis. Statistical analyses were performed using the Chi-square test, Kruskal-Wallis test, and logistic regression analyses. A difference in genotypic frequency of the P2X7R rs3751142 and CARD8 rs2043211 genes was not detected between gout and control patients. Clinical parameters including age, onset age, disease duration, body mass index, and serum uric acid levels were not different among the three genotypes for either P2X7R or CARD8 (P > 0.05 for all). A pair-wise comparison of P2X7R rs3751142 and CARD8 rs2043211 genotype combinations revealed that subjects with the CA P2X7R rs3751142 genotype and the TT CARD8 rs2043211 genotype had a trend toward a higher risk of gout compared to the CC/AA combination (P = 0.056, OR = 2.618, 95% CI 0.975 - 7.031). In conclusion, this study revealed that genetic variability of the P2X7R rs3751142 and CARD8 rs2043211 genes might, in part, be associated with susceptibility for gout.
Burkhalter, Kristen L; Wiggins, Keenan; Burkett-Cadena, Nathan; Alto, Barry W
2018-05-04
Commercially available assays utilizing antigen or nucleic acid detection chemistries provide options for mosquito control districts to screen their mosquito populations for arboviruses and make timely operational decisions regarding vector control. These assays may be utilized even more advantageously when combined with honey-soaked nucleic acid preservation substrate ('honey card') testing by reducing or replacing the time- and labor-intensive efforts of identifying and processing mosquito pools. We tested artificially inoculated honey cards and cards fed upon individually by West Nile virus (WNV) and Zika virus (ZIKV)-infected mosquitoes with three assays to compare detection rates and the limit of detection for each platform with respect to virus detection of a single infected mosquito and quantify the time interval of virus preservation on the cards. Assays evaluated included CDC protocols for real-time reverse transcriptase polymerase chain reaction (RT-PCR) for WNV and ZIKV, Pro-Lab Diagnostics ProAmpRT WNV loop-mediated amplification (LAMP) and ZIKV LAMP assays, and the Rapid Analyte Measurement Platform (RAMP) WNV assay. Real-time RT-PCR was the most sensitive assay and the most robust to viral RNA degradation over time. To maximize the detection of virus, honey cards should be left in the traps ≤1 d if using LAMP assays and ≤3 d if using real-time RT-PCR to detect viruses from field samples. The WNV RAMP assay, although effective for pool screening, lacks sensitivity required for honey card surveillance. Future studies may determine the minimum number of infectious mosquitoes required to feed on a honey card that would be reliably detected by the LAMP or RAMP assays.
MalaCards: an integrated compendium for diseases and their annotation
Rappaport, Noa; Nativ, Noam; Stelzer, Gil; Twik, Michal; Guan-Golan, Yaron; Iny Stein, Tsippi; Bahir, Iris; Belinky, Frida; Morrey, C. Paul; Safran, Marilyn; Lancet, Doron
2013-01-01
Comprehensive disease classification, integration and annotation are crucial for biomedical discovery. At present, disease compilation is incomplete, heterogeneous and often lacking systematic inquiry mechanisms. We introduce MalaCards, an integrated database of human maladies and their annotations, modeled on the architecture and strategy of the GeneCards database of human genes. MalaCards mines and merges 44 data sources to generate a computerized card for each of 16 919 human diseases. Each MalaCard contains disease-specific prioritized annotations, as well as inter-disease connections, empowered by the GeneCards relational database, its searches and GeneDecks set analyses. First, we generate a disease list from 15 ranked sources, using disease-name unification heuristics. Next, we use four schemes to populate MalaCards sections: (i) directly interrogating disease resources, to establish integrated disease names, synonyms, summaries, drugs/therapeutics, clinical features, genetic tests and anatomical context; (ii) searching GeneCards for related publications, and for associated genes with corresponding relevance scores; (iii) analyzing disease-associated gene sets in GeneDecks to yield affiliated pathways, phenotypes, compounds and GO terms, sorted by a composite relevance score and presented with GeneCards links; and (iv) searching within MalaCards itself, e.g. for additional related diseases and anatomical context. The latter forms the basis for the construction of a disease network, based on shared MalaCards annotations, embodying associations based on etiology, clinical features and clinical conditions. This broadly disposed network has a power-law degree distribution, suggesting that this might be an inherent property of such networks. Work in progress includes hierarchical malady classification, ontological mapping and disease set analyses, striving to make MalaCards an even more effective tool for biomedical research. Database URL: http://www.malacards.org/ PMID:23584832
Clarke, P Ryan; Edwards, William H; Hennager, Steven G; Block, Jean F; Yates, Angela M; Ebel, Eric; Knopp, Douglas J; Fuentes-Sanchez, Antonio; Jennings-Gaines, Jessica; Kientz, Rebecca L; Simunich, Marilyn
2015-07-01
Brucellosis (caused by the bacterium Brucella abortus) is a zoonotic disease endemic in wild elk (Cervus canadensis) of the Greater Yellowstone Ecosystem, US. Because livestock and humans working with elk or livestock are at risk, validated tests to detect the B. abortus antibody in elk are needed. Using the κ-statistic, we evaluated the buffered, acidified plate antigen (BAPA) assay for agreement with the results of the four serologic tests (card test [card], complement fixation test [CF], rivanol precipitation plate agglutination test [RIV], standard plate agglutination test [SPT]) that are approved by the US Department of Agriculture for the detection of the B. abortus antibody in elk. From 2006 to 2010, serum samples collected from elk within B. abortus-endemic areas (n = 604) and nonendemic areas (n = 707) and from elk culture-positive for B. abortus (n = 36) were split and blind tested by four elk serum diagnostic laboratories. κ-Values showed a high degree of agreement for the card (0.876), RIV (0.84), and CF (0.774) test pairings and moderate agreement for the SPT (0.578). Sensitivities for the BAPA, card, RIV, CF, and SPT were 0.859, 0.839, 0.899, 1.00, and 0.813, whereas specificities were 0.986, 0.993, 0.986, 0.98, and 0.968, respectively. The positive predictive values and the negative predictive values were calculated for 2.6%, 8.8%, and 16.2% prevalence levels. These findings suggest the BAPA test is a suitable screening test for the B. abortus antibodies in elk.
Use of electronic fare transaction data for corridor planning.
DOT National Transportation Integrated Search
2017-06-01
This report documents the initial phase of a project that developed, tested, and used a methodology and tool set for converting electronic transit agency fare card transaction data, the Puget Sound regions ORCA electronic fare card, into informati...
Potential for Personal Digital Assistant interference with implantable cardiac devices.
Tri, Jeffrey L; Trusty, Jane M; Hayes, David L
2004-12-01
To determine whether the wireless local area network (WLAN) technology, specifically the Personal Digital Assistant (PDA), interferes with implantable cardiac pacemakers and defibrillators. Various pacemakers and defibrillators were tested in vitro at the Mayo Clinic in Rochester, Minn, between March 6 and July 30, 2003. These cardiac devices were exposed to an HP Compaq IPAQ PDA fitted with a Cisco Aironet WLAN card. Initial testing was designed to show whether the Aironet card radiated energy in a consistent pattern from the antenna of the PDA to ensure that subsequent cardiac device testing would not be affected by the orientation of the PDA to the cardiac device. Testing involved placing individual cardiac devices in a simulator and uniformly exposing each device at its most sensitive programmable value to the WLAN card set to maximum power. During testing with the Cisco WLAN Aironet card, all devices programmed to the unipolar or bipolar configuration single- or dual-chamber mode had normal pacing and sensing functions and exhibited no effects of electromagnetic interference except for 1 implantable cardioverter-defibrillator (ICD). This aberration was determined to relate to the design of the investigators' testing apparatus and not to the output of the PDA. The ICD device appropriately identified and labeled the electromagnetic aberration as "noise." We documented no electromagnetic interference caused by the WLAN technology by using in vitro testing of pacemakers and ICDs; however, testing ideally should be completed in vivo to confirm the lack of any clinically important interactions.
Nymo, Ingebjørg Helena; Beckmen, Kimberlee; Godfroid, Jacques
2016-01-01
We used an indirect enzyme-linked immunosorbent assay (iELISA) and the rose bengal test (RBT) to test for anti-Brucella antibodies in moose (Alces alces gigas), muskoxen (Ovibos moschatus), and plains bison (Bison bison bison) from various game management units (GMUs) in Alaska, US, sampled from 1982 to 2010. A portion of the sera had previously been tested with the standard plate test (SPT), the buffered Brucella antigen (BBA) card test, and the card test (CARD). No antibody-positive plains bison were identified. Anti-Brucella antibodies were detected in moose (iELISA, n=4/87; RBT, n=4/87; SPT, n=4/5; BBA, n=4/4) from GMU 23 captured in 1992, 1993, and 1995 and in muskoxen (iELISA, n=4/52; RBT, n=4/52; CARD, n=4/35) from GMUs 26A and 26B captured in 2004, 2006, and 2007. A negative effect of infection on the health of individuals of these species is probable. The presence of antibody-positive animals from 1992 to 2007 suggests presence of brucellae over time. The antibody-positive animals were found in northern Alaska, an area with a historically higher prevalence of Brucella-positive caribou, and a spillover of Brucella suis biovar 4 from caribou may have occurred. Brucella suis biovar 4 causes human brucellosis, and transmission from consumption of moose and muskoxen is possible.
A computer graphics display and data compression technique
NASA Technical Reports Server (NTRS)
Teague, M. J.; Meyer, H. G.; Levenson, L. (Editor)
1974-01-01
The computer program discussed is intended for the graphical presentation of a general dependent variable X that is a function of two independent variables, U and V. The required input to the program is the variation of the dependent variable with one of the independent variables for various fixed values of the other. The computer program is named CRP, and the output is provided by the SD 4060 plotter. Program CRP is an extremely flexible program that offers the user a wide variety of options. The dependent variable may be presented in either a linear or a logarithmic manner. Automatic centering of the plot is provided in the ordinate direction, and the abscissa is scaled automatically for a logarithmic plot. A description of the carpet plot technique is given along with the coordinates system used in the program. Various aspects of the program logic are discussed and detailed documentation of the data card format is presented.
Automatic detection and classification of obstacles with applications in autonomous mobile robots
NASA Astrophysics Data System (ADS)
Ponomaryov, Volodymyr I.; Rosas-Miranda, Dario I.
2016-04-01
Hardware implementation of an automatic detection and classification of objects that can represent an obstacle for an autonomous mobile robot using stereo vision algorithms is presented. We propose and evaluate a new method to detect and classify objects for a mobile robot in outdoor conditions. This method is divided in two parts, the first one is the object detection step based on the distance from the objects to the camera and a BLOB analysis. The second part is the classification step that is based on visuals primitives and a SVM classifier. The proposed method is performed in GPU in order to reduce the processing time values. This is performed with help of hardware based on multi-core processors and GPU platform, using a NVIDIA R GeForce R GT640 graphic card and Matlab over a PC with Windows 10.
Raina, A; Hennessy, R; Rains, M; Allred, J; Hirshburg, J M; Diven, D G; Markey, M K
2016-08-01
Traditional metrics for evaluating the severity of psoriasis are subjective, which complicates efforts to measure effective treatments in clinical trials. We collected images of psoriasis plaques and calibrated the coloration of the images according to an included color card. Features were extracted from the images and used to train a linear discriminant analysis classifier with cross-validation to automatically classify the degree of erythema. The results were tested against numerical scores obtained by a panel of dermatologists using a standard rating system. Quantitative measures of erythema based on the digital color images showed good agreement with subjective assessment of erythema severity (κ = 0.4203). The color calibration process improved the agreement from κ = 0.2364 to κ = 0.4203. We propose a method for the objective measurement of the psoriasis severity parameter of erythema and show that the calibration process improved the results. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
ERIC Educational Resources Information Center
Breslin, Casey M.; Robinson, Leah E.; Rudisill, Mary E.
2013-01-01
Performance on the Test of Gross Motor Development (Second Edition; TGMD-2) by children with autism spectrum disorders improves when picture task cards were implemented into the assessment protocol [Breslin, C.M., & Rudisill, M.E. (2011). "The effect of visual supports on performance of the TGMD-2 for children with autism spectrum…
HLA Typing for Bone Marrow Transplantation
2011-07-21
Confirmatory Testing DC Donor Center DIY Do it yourself DNA Deoxyribonucleic Acid DOD Department of Defense D/R Donor/Recipient EBMT European...testing information is complete, thus allowing for report card analysis earlier in the process. • Deployed functionality to allow cord banks the ability...inventory was labeled with a new Report Card Status: “PreOrder Condition”). • Developed features to support Local IDs and International Society Blood
ERIC Educational Resources Information Center
Steinmetz, Jean-Paul; Brunner, Martin; Loarer, Even; Houssemand, Claude
2010-01-01
The Wisconsin Card Sorting Test (WCST) assesses executive and frontal lobe function and can be administered manually or by computer. Despite the widespread application of the 2 versions, the psychometric equivalence of their scores has rarely been evaluated and only a limited set of criteria has been considered. The present experimental study (N =…
Assessing a Couple's Relationship and Compatibility Using the MARI[R] Card Test and Mandala Drawings
ERIC Educational Resources Information Center
Frame, Phyllis G.
2006-01-01
This paper illustrates the use of the MARI[R] Card Test, a transpersonal assessment tool which includes archetypal designs and color choices, as well as the drawing of a white and black mandala, or circle picture, for assessing the compatibility of two people in a committed relationship. In an informal pilot research study, 22 couples were given…
Neumann, M; Friedl, S; Meining, A; Egger, K; Heldwein, W; Rey, J F; Hochberger, J; Classen, M; Hohenberger, W; Rösch, T
2002-10-01
In most European countries, training in GI endoscopy has largely been based on hands-on acquisition of experience in patients rather than on a structured training programme. With the development of training models systematic hands-on training in a variety of diagnostic and therapeutic endoscopy techniques was achieved. Little, however, is known about methods of objectively assessing trainees' performance. We therefore developed an assessment 'score card' for upper GI endoscopy and tested it in endoscopists with various levels of experience. The aim of the study was therefore to assess interobserver variations in the evaluation of trainees. On the basis of textbook and expert opinions a consensus group of eight experienced endoscopists developed a score card for diagnostic upper GI endoscopy with biopsy. The score card includes an assessment of the single steps of the procedure as well as of the times needed to complete each step. This score card was then evaluated in a further conference including ten experts who blindly assessed videotapes of 15 endoscopists performing upper GI endoscopy in a training bio-simulation model (the 'Erlangen Endo-Trainer'). On the basis of their previous experience (i. e. the number of endoscopies performed) these 15 endoscopists were classified into four groups: very experienced, experienced, having some experience and inexperienced. Interobserver variability (IOV) was tested for the various score card parameters (Kendall's rank-correlation coefficient 0.0-0.5 poor, 0.5-1.0 good agreement). In addition, the correlation between the score card assessment and the examiners' experience levels was analysed. Despite poor IOV results for all the parameters tested (Kendall coefficient < 0.3), the assessment parameters correlated well when the examiners' different experience levels were taken into account (correlation coefficient 0.59-0.89, p < 0.05). The score card parameters were suitable for differentiating between the four groups of examiners with different levels of endoscopic experience. As expected with scores involving subjective assessment of performance, the variability between reviewers was substantial. Nevertheless, the assessment score was capable of distinguishing reliably between different experience levels in terms of a good individual observer consistency. The score card can therefore be used to document both training status and progress during endoscopy training courses using bio-simulation models, and this might be able to provide improved quality assurance in GI endoscopy training.
Dong, Li; Lin, Chunqing; Li, Li; Wang, Margaret; Cui, Jianfeng; Feng, Ruimei; Liu, Bin; Wu, Zeni; Lian, Jia; Liao, Guangdong; Chen, Wen; Qiao, Youlin
2017-09-01
Effective dry storage and transport media as an alternative to conventional liquid-based medium would facilitate the accessibility of women in the low-resource settings to human papillomavirus (HPV)- based cervical cancer screening. To evaluate analytical and clinical performance of indicating FTA™ Elute Cartridge (FTA card) for the detection of HPV16/18 and cervical precancerous lesions and cancer compared to dry swab and liquid medium. Ninety patients with abnormal cytology and/or HPV infection were included for analysis. Three specimens of cervical exfoliated cells from each woman were randomly collected by FTA card, dry swab or liquid-based medium prior to colposcopy examination. The subsequent HPV DNA tests were performed on cobas 4800 HPV platform. High-risk HPV (hrHPV) positivity rate was 63.3%, 62.2% and 65.6% for samples collected by FTA card, dry swab and liquid medium, respectively. The overall agreements and kappa values for the detection of hrHPV, HPV 16 and HPV 18 between FTA card and liquid-based medium were 88.9% (κ=0.76), 97.8% (κ=0.94) and 100% (κ=1.0),respectively; between FTA card and dry swab were 92.1% (κ=0.83), 94.5% (κ=0.87) and 100% (κ=1.0), respectively. The performances of hrHPV tested by FTA card, dry swab, and liquid-based medium for detecting CIN2+ were comparable in terms of the sensitivity and specificity. The specificity of detection of CIN2+ by HPV16/18 increased by approximately 40% compared to hrHPV for any medium albeit at cost of a moderate loss of sensitivity. Dry medium might offer an alternative to conventional liquid-based medium in the HPV-based cervical cancer screening program especially in low-resource settings but still needs further evaluation. Copyright © 2017. Published by Elsevier B.V.
Haghani, Fariba; Hatef Khorami, Mohammad; Fakhari, Mohammad
2016-07-01
Feedback cards are recommended as a feasible tool for structured written feedback delivery in clinical education while effectiveness of this tool on the medical students' performance is still questionable. The purpose of this study was to compare the effects of structured written feedback by cards as well as verbal feedback versus verbal feedback alone on the clinical performance of medical students at the Mini Clinical Evaluation Exercise (Mini-CEX) test in an outpatient clinic. This is a quasi-experimental study with pre- and post-test comprising four groups in two terms of medical students' externship. The students' performance was assessed through the Mini-Clinical Evaluation Exercise (Mini-CEX) as a clinical performance evaluation tool. Structured written feedbacks were given to two experimental groups by designed feedback cards as well as verbal feedback, while in the two control groups feedback was delivered verbally as a routine approach in clinical education. By consecutive sampling method, 62 externship students were enrolled in this study and seven students were excluded from the final analysis due to their absence for three days. According to the ANOVA analysis and Post Hoc Tukey test, no statistically significant difference was observed among the four groups at the pre-test, whereas a statistically significant difference was observed between the experimental and control groups at the post-test (F = 4.023, p =0.012). The effect size of the structured written feedbacks on clinical performance was 0.19. Structured written feedback by cards could improve the performance of medical students in a statistical sense. Further studies must be conducted in other clinical courses with longer durations.
A graphics-card implementation of Monte-Carlo simulations for cosmic-ray transport
NASA Astrophysics Data System (ADS)
Tautz, R. C.
2016-05-01
A graphics card implementation of a test-particle simulation code is presented that is based on the CUDA extension of the C/C++ programming language. The original CPU version has been developed for the calculation of cosmic-ray diffusion coefficients in artificial Kolmogorov-type turbulence. In the new implementation, the magnetic turbulence generation, which is the most time-consuming part, is separated from the particle transport and is performed on a graphics card. In this article, the modification of the basic approach of integrating test particle trajectories to employ the SIMD (single instruction, multiple data) model is presented and verified. The efficiency of the new code is tested and several language-specific accelerating factors are discussed. For the example of isotropic magnetostatic turbulence, sample results are shown and a comparison to the results of the CPU implementation is performed.
Noh, Jaekwang; Ko, Hak Hyun; Yun, Yeomin; Choi, Young Sook; Lee, Sang Gon; Shin, Sue; Han, Kyou Sup; Song, Eun Young
2008-08-01
We evaluated the performance and false positive rate of Mediace RPR test (Sekisui, Japan), a newly introduced nontreponemal test using a chemistry autoanalyzer. The sensitivity of Mediace RPR test was analyzed using sera from 50 patients with syphilis in different stages (8 primary, 7 secondary, and 35 latent), 14 sera positive with fluorescent treponemal antibody absorption (FTA-ABS) IgM, and 74 sera positive with conventional rapid plasma regain (RPR) card test (Asan, Korea) and also positive with Treponema pallidum hemagglutination (TPHA) test or FTA-ABS IgG test. The specificity was analyzed on 108 healthy blood donors. We also performed RPR card test on 302 sera that had been tested positive with Mediace RPR test and also performed TPHA or FTA-ABS IgG test to analyze the false positive rate of Mediace RPR test. A cutoff value of 0.5 R.U. (RPR unit) was used for Mediace RPR test. Mediace RPR test on syphilitic sera of different stages (primary, secondary, and latent stages) and FTA-ABS IgM positive sera showed a sensitivity of 100%, 100%, 82.9% and 100%, respectively. Among the 74 sera positive with conventional RPR card test and TPHA or FTA-ABS IgG test, 55 were positive with Mediace test. The specificity of Mediace RPR test on blood donors was 97.2%. Among the 302 sera positive with Mediace RPR test, 137 sera (45.4%) were negative by RPR card and TPHA/FTA-ABS IgG tests. Although the sensitivities of Mediace RPR were good for primary and secondary syphilis, due to its high negative rate of Mediace RPR over the conventional RPR positive samples, further studies are necessary whether it can replace conventional nontreponemal test for screening purpose. Moreover, in view of the high false positive rate, positive results by Mediace RPR test should be confirmed with treponemal tests.
A New Patient Record System Using the Laser Card
Brown, J.H.U.; Vallbona, Carlos
1988-01-01
A method of handling medical data in the form of patient records including physical findings such as x-rays has been devised using a laser card coupled to a p.c. for data input and output. A satisfactory software system which encompasses a formalized medical record system dealing with events rather than chronological order of entry has been devised and is now under test in a community health clinic. Future directions of the card research are discussed and expanded upon. ImagesFig. 7
Mas, Sergi; Crescenti, Anna; Gassó, Patricia; Vidal-Taboada, Jose M; Lafuente, Amalia
2007-08-01
As pharmacogenetic studies frequently require establishment of DNA banks containing large cohorts with multi-centric designs, inexpensive methods for collecting and storing high-quality DNA are needed. The aims of this study were two-fold: to compare the amount and quality of DNA obtained from two different DNA cards (IsoCode Cards or FTA Classic Cards, Whatman plc, Brentford, Middlesex, UK); and to evaluate the effects of time and storage temperature, as well as the influence of anticoagulant ethylenediaminetetraacetic acid on the DNA elution procedure. The samples were genotyped by several methods typically used in pharmacogenetic studies: multiplex PCR, PCR-restriction fragment length polymorphism, single nucleotide primer extension, and allelic discrimination assay. In addition, they were amplified by whole genome amplification to increase genomic DNA mass. Time, storage temperature and ethylenediaminetetraacetic acid had no significant effects on either DNA card. This study reveals the importance of drying blood spots prior to isolation to avoid haemoglobin interference. Moreover, our results demonstrate that re-isolation protocols could be applied to increase the amount of DNA recovered. The samples analysed were accurately genotyped with all the methods examined herein. In conclusion, our study shows that both DNA cards, IsoCode Cards and FTA Classic Cards, facilitate genetic and pharmacogenetic testing for routine clinical practice.
Comparison of Fecal Collection Methods for Microbiota Studies in Bangladesh
Chen, Jun; Kibriya, Muhammad G.; Chen, Yu; Islam, Tariqul; Eunes, Mahbubul; Ahmed, Alauddin; Naher, Jabun; Rahman, Anisur; Amir, Amnon; Shi, Jianxin; Abnet, Christian C.; Nelson, Heidi; Knight, Rob; Chia, Nicholas; Ahsan, Habibul; Sinha, Rashmi
2017-01-01
ABSTRACT To our knowledge, fecal microbiota collection methods have not been evaluated in low- and middle-income countries. Therefore, we evaluated five different fecal sample collection methods for technical reproducibility, stability, and accuracy within the Health Effects of Arsenic Longitudinal Study (HEALS) in Bangladesh. Fifty participants from the HEALS provided fecal samples in the clinic which were aliquoted into no solution, 95% ethanol, RNAlater, postdevelopment fecal occult blood test (FOBT) cards, and fecal immunochemical test (FIT) tubes. Half of the aliquots were frozen immediately at −80°C (day 0) and the remaining samples were left at ambient temperature for 96 h and then frozen (day 4). Intraclass correlation coefficients (ICC) were calculated for the relative abundances of the top three phyla, for two alpha diversity measures, and for four beta diversity measures. The duplicate samples had relatively high ICCs for technical reproducibility at day 0 and day 4 (range, 0.79 to 0.99). The FOBT card and samples preserved in RNAlater and 95% ethanol had the highest ICCs for stability over 4 days. The FIT tube had lower stability measures overall. In comparison to the “gold standard” method using immediately frozen fecal samples with no solution, the ICCs for many of the microbial metrics were low, but the rank order appeared to be preserved as seen by the Spearman correlation. The FOBT cards, 95% ethanol, and RNAlater were effective fecal preservatives. These fecal collection methods are optimal for future cohort studies, particularly in low- and middle-income countries. IMPORTANCE The collection of fecal samples in prospective cohort studies is essential to provide the opportunity to study the effect of the human microbiota on numerous health conditions. However, these collection methods have not been adequately tested in low- and middle-income countries. We present estimates of technical reproducibility, stability at ambient temperature for 4 days, and accuracy comparing a “gold standard” for fecal samples in no solution, 95% ethanol, RNAlater, postdevelopment fecal occult blood test cards, and fecal immunochemical test tubes in a study conducted in Bangladesh. Fecal occult blood test cards and fecal samples stored in 95% ethanol or RNAlater adequately preserve fecal samples in this setting. Therefore, new studies in low- and middle-income countries should include collection of fecal samples using fecal occult blood test cards, 95% ethanol, or RNAlater for prospective cohort studies. PMID:28258145
Substances that interfere with guaiac card tests: implications for gastric aspirate testing.
Gogel, H K; Tandberg, D; Strickland, R G
1989-09-01
Previous studies have shown that acidic pH and several ingestible substances can cause misleading guaiac tests of gastric aspirates. In this in vitro study, over 100 foods, beverages, and drugs were diluted to concentrations potentially present in the stomachs of outpatients being evaluated for gastrointestinal bleeding. These were mixed with known concentrations of blood and tested with different brands of guaiac cards. Decreased guaiac test sensitivity was associated with activated charcoal, dimethylaminoethanol, red chile, N-acetylcysteine, rifampin, red Jell-O (General Foods Corp, White Plains, NY), orange juice, Pepto-Bismol (Norwich Eaton Pharmaceuticals, Norwich, NY), simethicone, spaghetti sauce, and several red wines. Chlorophyll and methylene blue-containing tablets produced false-positive results, but other blue and blue-green colored tablets did not, except at high concentrations. Previously described false-negative results with vitamin C, bile, and certain antacids were confirmed, as were false-positive results with iodide, bromide, cupric sulfate, iron salts, and hypochlorite. Physicians should exercise caution when interpreting guaiac card tests of gastric aspirates, especially in the outpatient setting.
The microassay on a card: A rugged, portable immunoassay
NASA Technical Reports Server (NTRS)
Kidwell, David
1991-01-01
The Microassay on a Card (MAC) is a portable, hand-held, non-instrumental immunoassay that can test for the presence of a wide variety of substances in the environment. The MAC is a simple device to use. A drop of test solution is placed on one side of the card and within five minutes a color is developed on the other side in proportion to the amount of substance in the test solution, with sensitivity approaching 10 ng/ml. The MAC is self-contained and self-timed; no reagents or timing is necessary. The MAC may be configured with multiple wells to provide simultaneous testing for multiple species. As envisioned, the MAC will be employed first as an on-site screen for drugs of abuse in urine or saliva. If the MAC can be used as a screen of saliva for drugs of abuse, it could be applied to driving while intoxicated, use of drugs on the job, or testing of the identity of seized materials. With appropriate modifications, the MAC also could be used to test for environmental toxins or pollutants.
Latent structure of the Wisconsin Card Sorting Test: a confirmatory factor analytic study.
Greve, Kevin W; Stickle, Timothy R; Love, Jeffrey M; Bianchini, Kevin J; Stanford, Matthew S
2005-05-01
The present study represents the first large scale confirmatory factor analysis of the Wisconsin Card Sorting Test (WCST). The results generally support the three factor solutions reported in the exploratory factor analysis literature. However, only the first factor, which reflects general executive functioning, is statistically sound. The secondary factors, while likely reflecting meaningful cognitive abilities, are less stable except when all subjects complete all 128 cards. It is likely that having two discontinuation rules for the WCST has contributed to the varied factor analytic solutions reported in the literature and early discontinuation may result in some loss of useful information. Continued multivariate research will be necessary to better clarify the processes underlying WCST performance and their relationships to one another.
NASA Technical Reports Server (NTRS)
Caplin, R. S.; Royer, E. R.
1977-01-01
Design analysis of a microbial load monitor system flight engineering model was presented. Checkout of the card taper and media pump system was fabricated as well as the final two incubating reading heads, the sample receiving and card loading device assembly, related sterility testing, and software. Progress in these areas was summarized.
Carded Tow Real-Time Color Assessment: A Spectral Camera-Based System.
Furferi, Rocco; Governi, Lapo; Volpe, Yary; Carfagni, Monica
2016-08-31
One of the most important parameters to be controlled during the production of textile yarns obtained by mixing pre-colored fibers, is the color correspondence between the manufactured yarn and a given reference, usually provided by a designer or a customer. Obtaining yarns from raw pre-colored fibers is a complex manufacturing process entailing a number of steps such as laboratory sampling, color recipe corrections, blowing, carding and spinning. Carding process is the one devoted to transform a "fuzzy mass" of tufted fibers into a regular mass of untwisted fibers, named "tow". During this process, unfortunately, the correspondence between the color of the tow and the target one cannot be assured, thus leading to yarns whose color differs from the one used for reference. To solve this issue, the main aim of this work is to provide a system able to perform a spectral camera-based real-time measurement of a carded tow, to assess its color correspondence with a reference carded fabric and, at the same time, to monitor the overall quality of the tow during the carding process. Tested against a number of differently colored carded fabrics, the proposed system proved its effectiveness in reliably assessing color correspondence in real-time.
26 CFR 301.7701(b)-9 - Effective/applicability dates of §§ 301.7701(b)-1 through 301.7701(b)-7.
Code of Federal Regulations, 2010 CFR
2010-04-01
... years, see §§ 1.871-2 through 1.871-5 of this chapter. (b) Special rules—(1) Green card test-residency... green card test in 1985, be considered a resident of the United States as of January 1, 1985, regardless..., days of presence in 1984 will only be counted for aliens who had been residents under prior law (§§ 1...
Leccese, Fabio; Cagnetti, Marco; Trinca, Daniele
2014-01-01
A smart city application has been realized and tested. It is a fully remote controlled isle of lamp posts based on new technologies. It has been designed and organized in different hierarchical layers, which perform local activities to physically control the lamp posts and transmit information with another for remote control. Locally, each lamp post uses an electronic card for management and a ZigBee tlc network transmits data to a central control unit, which manages the whole isle. The central unit is realized with a Raspberry-Pi control card due to its good computing performance at very low price. Finally, a WiMAX connection was tested and used to remotely control the smart grid, thus overcoming the distance limitations of commercial Wi-Fi networks. The isle has been realized and tested for some months in the field. PMID:25529206
Leccese, Fabio; Cagnetti, Marco; Trinca, Daniele
2014-12-18
A smart city application has been realized and tested. It is a fully remote controlled isle of lamp posts based on new technologies. It has been designed and organized in different hierarchical layers, which perform local activities to physically control the lamp posts and transmit information with another for remote control. Locally, each lamp post uses an electronic card for management and a ZigBee tlc network transmits data to a central control unit, which manages the whole isle. The central unit is realized with a Raspberry-Pi control card due to its good computing performance at very low price. Finally, a WiMAX connection was tested and used to remotely control the smart grid, thus overcoming the distance limitations of commercial Wi-Fi networks. The isle has been realized and tested for some months in the field.
ERA 1103 UNIVAC 2 Calculating Machine
1955-09-21
The new 10-by 10-Foot Supersonic Wind Tunnel at the Lewis Flight Propulsion Laboratory included high tech data acquisition and analysis systems. The reliable gathering of pressure, speed, temperature, and other data from test runs in the facilities was critical to the research process. Throughout the 1940s and early 1950s female employees, known as computers, recorded all test data and performed initial calculations by hand. The introduction of punch card computers in the late 1940s gradually reduced the number of hands-on calculations. In the mid-1950s new computational machines were installed in the office building of the 10-by 10-Foot tunnel. The new systems included this UNIVAC 1103 vacuum tube computer—the lab’s first centralized computer system. The programming was done on paper tape and fed into the machine. The 10-by 10 computer center also included the Lewis-designed Computer Automated Digital Encoder (CADDE) and Digital Automated Multiple Pressure Recorder (DAMPR) systems which converted test data to binary-coded decimal numbers and recorded test pressures automatically, respectively. The systems primarily served the 10-by 10, but were also applied to the other large facilities. Engineering Research Associates (ERA) developed the initial UNIVAC computer for the Navy in the late 1940s. In 1952 the company designed a commercial version, the UNIVAC 1103. The 1103 was the first computer designed by Seymour Cray and the first commercially successful computer.
Franck, J.V.; Broadhead, P.S.; Skiff, E.W.
1959-07-14
A semiautomatic measuring projector particularly adapted for measurement of the coordinates of photographic images of particle tracks as prcduced in a bubble or cloud chamber is presented. A viewing screen aids the operator in selecting a particle track for measurement. After approximate manual alignment, an image scanning system coupled to a servo control provides automatic exact alignment of a track image with a reference point. The apparatus can follow along a track with a continuous motion while recording coordinate data at various selected points along the track. The coordinate data is recorded on punched cards for subsequent computer calculation of particle trajectory, momentum, etc.
Delayed Match Retrieval: a novel anticipation-based visual working memory paradigm.
Kaldy, Zsuzsa; Guillory, Sylvia B; Blaser, Erik
2016-11-01
We tested 8- and 10-month-old infants' visual working memory (VWM) for object-location bindings - what is where - with a novel paradigm, Delayed Match Retrieval, that measured infants' anticipatory gaze responses (using a Tobii T120 eye tracker). In an inversion of Delayed-Match-to-Sample tasks and with inspiration from the game Memory, in test trials, three face-down virtual 'cards' were presented. Two flipped over sequentially (revealing, e.g. a swirl pattern and then a star), and then flipped back face-down. Next, the third card was flipped to reveal a match (e.g. a star) to one of the previously seen, now face-down cards. If infants looked to the location where the (now face-down) matching card had been shown, this was coded as a correct response. To encourage anticipatory looks, infants subsequently received a reward (a brief, engaging animation) presented at that location. Ten-month-old infants performed significantly above chance, showing that their VWM could hold object-location information for the two cards. Overall, 8-month-olds' performance was at chance, but they showed a robust learning trend. These results corroborate previous findings (Kaldy & Leslie, 2005; Oakes, Ross-Sheehy & Luck, 2006) and point to rapid development of VWM for object-location bindings. However, compared to previous paradigms that measure passive gaze responses to novelty, this paradigm presents a more challenging, ecologically relevant test of VWM, as it measures the ability to make online predictions and actively localize objects based on VWM. In addition, this paradigm can be readily scaled up to test toddlers or older children without significant modification. © 2015 John Wiley & Sons Ltd.
A unified approach for development of Urdu Corpus for OCR and demographic purpose
NASA Astrophysics Data System (ADS)
Choudhary, Prakash; Nain, Neeta; Ahmed, Mushtaq
2015-02-01
This paper presents a methodology for the development of an Urdu handwritten text image Corpus and application of Corpus linguistics in the field of OCR and information retrieval from handwritten document. Compared to other language scripts, Urdu script is little bit complicated for data entry. To enter a single character it requires a combination of multiple keys entry. Here, a mixed approach is proposed and demonstrated for building Urdu Corpus for OCR and Demographic data collection. Demographic part of database could be used to train a system to fetch the data automatically, which will be helpful to simplify existing manual data-processing task involved in the field of data collection such as input forms like Passport, Ration Card, Voting Card, AADHAR, Driving licence, Indian Railway Reservation, Census data etc. This would increase the participation of Urdu language community in understanding and taking benefit of the Government schemes. To make availability and applicability of database in a vast area of corpus linguistics, we propose a methodology for data collection, mark-up, digital transcription, and XML metadata information for benchmarking.
Tam, Ka Ian; Esona, Mathew D.; Williams, Alice; Ndze, Valentine N.; Boula, Angeline; Bowen, Michael D.
2015-01-01
Rotavirus is the most important cause of severe childhood gastroenteritis worldwide. Rotavirus vaccines are available and rotavirus surveillance is carried out to assess vaccination impact. In surveillance studies, stool samples are stored typically at 4°C or frozen to maintain sample quality. Uninterrupted cold storage is a problem in developing countries because of power interruptions. Cold-chain transportation of samples from collection sites to testing laboratories is costly. In this study, we evaluated the use of BBL™ Sensi-Discs™ and FTA® cards for storage and transportation of samples for virus isolation, EIA, and RT-PCR testing. Infectious rotavirus was recovered after 30 days of storage on Sensi-Discs™ at room temperature. We were able to genotype 98–99% of samples stored on Sensi-Discs™ and FTA® cards at temperatures ranging from −80°C to 37°C up to 180 days. A field sampling test using samples prepared and shipped from Cameroon, showed that both matrices yielded 100% genotyping success compared with whole stool and Sensi-Discs™ demonstrated 95% concordance with whole stool in EIA testing. The utilization of BBL™ Sensi-Discs™ and FTA® cards for stool sample storage and shipment has the potential to have great impact on global public health by facilitating surveillance and epidemiological investigations of rotavirus strains worldwide at a reduced cost. PMID:26022083
Tam, Ka Ian; Esona, Mathew D; Williams, Alice; Ndze, Valantine N; Boula, Angeline; Bowen, Michael D
2015-09-15
Rotavirus is the most important cause of severe childhood gastroenteritis worldwide. Rotavirus vaccines are available and rotavirus surveillance is carried out to assess vaccination impact. In surveillance studies, stool samples are stored typically at 4°C or frozen to maintain sample quality. Uninterrupted cold storage is a problem in developing countries because of power interruptions. Cold-chain transportation of samples from collection sites to testing laboratories is costly. In this study, we evaluated the use of BBL™ Sensi-Discs™ and FTA(®) cards for storage and transportation of samples for virus isolation, EIA, and RT-PCR testing. Infectious rotavirus was recovered after 30 days of storage on Sensi-Discs™ at room temperature. We were able to genotype 98-99% of samples stored on Sensi-Discs™ and FTA(®) cards at temperatures ranging from -80°C to 37°C up to 180 days. A field sampling test using samples prepared and shipped from Cameroon, showed that both matrices yielded 100% genotyping success compared with whole stool and Sensi-Discs™ demonstrated 95% concordance with whole stool in EIA testing. The utilization of BBL™ Sensi-Discs™ and FTA(®) cards for stool sample storage and shipment has the potential to have great impact on global public health by facilitating surveillance and epidemiological investigations of rotavirus strains worldwide at a reduced cost. Published by Elsevier B.V.
`Membership Has Its Privileges': Status Incentives and Categorical Inequality in Education
Domina, Thurston; Penner, Andrew M.; Penner, Emily K.
2015-01-01
Prizes – formal systems that publicly allocate rewards for exemplary behavior – play an increasingly important role in a wide array of social settings, including education. In this paper, we evaluate a prize system designed to boost achievement at two high schools by assigning students color-coded ID cards based on a previously low stakes test. Average student achievement on this test increased in the ID card schools beyond what one would expect from contemporaneous changes in neighboring schools. However, regression discontinuity analyses indicate that the program created new inequalities between students who received low-status and high-status ID cards. These findings indicate that status-based incentives create categorical inequalities between prize winners and others even as they reorient behavior toward the goals they reward. PMID:27213170
An Instructional Merger: HyperCard and the Integrative Teaching Model.
ERIC Educational Resources Information Center
Massie, Carolyn M.; Volk, Larry G.
Teaching methods have been developed and tested that encourage students to process information and refine their thinking skills. The information processing model is known as the Integrative Teaching Model. By combining the computer technology in the HyperCard application for data display and retrieval, instructional delivery of this teaching model…
Using Behavioral Skills Training and Video Rehearsal to Teach Blackjack Skills
ERIC Educational Resources Information Center
Speelman, Ryan C.; Whiting, Seth W.; Dixon, Mark R.
2015-01-01
A behavioral skills training procedure that consisted of video instructions, video rehearsal, and video testing was used to teach 4 recreational gamblers a specific skill in playing blackjack (sometimes called "card counting"). A multiple baseline design was used to evaluate intervention effects on card-counting accuracy and chips won or…
Carded Tow Real-Time Color Assessment: A Spectral Camera-Based System
Furferi, Rocco; Governi, Lapo; Volpe, Yary; Carfagni, Monica
2016-01-01
One of the most important parameters to be controlled during the production of textile yarns obtained by mixing pre-colored fibers, is the color correspondence between the manufactured yarn and a given reference, usually provided by a designer or a customer. Obtaining yarns from raw pre-colored fibers is a complex manufacturing process entailing a number of steps such as laboratory sampling, color recipe corrections, blowing, carding and spinning. Carding process is the one devoted to transform a “fuzzy mass” of tufted fibers into a regular mass of untwisted fibers, named “tow”. During this process, unfortunately, the correspondence between the color of the tow and the target one cannot be assured, thus leading to yarns whose color differs from the one used for reference. To solve this issue, the main aim of this work is to provide a system able to perform a spectral camera-based real-time measurement of a carded tow, to assess its color correspondence with a reference carded fabric and, at the same time, to monitor the overall quality of the tow during the carding process. Tested against a number of differently colored carded fabrics, the proposed system proved its effectiveness in reliably assessing color correspondence in real-time. PMID:27589765
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rembold, Randy Kai; Hart, Darren M.
Sandia National Laboratories has tested and evaluated Geotech SMART24BH borehole data acquisition system with active Fortezza crypto card data signing and authentication. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of two Geotech SMART24BH digitizers with a Fortezza PCMCIAmore » crypto card actively implementing the signing of data packets. The results of this evaluation were compared to relevant specifications provided within manufacturer's documentation notes. The tests performed were chosen to demonstrate different performance aspects of the digitizer under test. The performance aspects tested include determining noise floor, least significant bit (LSB), dynamic range, cross-talk, relative channel-to-channel timing, time-tag accuracy/statistics/drift, analog bandwidth.« less
NASA Technical Reports Server (NTRS)
Whitson, Peggy A. (Inventor); Clift, Vaughan L. (Inventor)
1994-01-01
The present invention provides a simple, portable, relatively inexpensive apparatus for accurately and efficiently collecting, separating, testing, and even storing between about 1-20 ml, preferably about 1-10 ml, of blood or other bodily fluid in situ. The apparatus includes a collection chamber bounded on its sides by an opening in a sheet of material, preferably clear plastic, abutting a filter card. The filter card is made of fibrous material, preferably less than about a millimeter thick, having an average pore size of less than about 3 microns. Preferably, the fibers are glass and the fibrous material has an average pore size of about 1 micron. The fibrous material is treated with a carbohydrate/protein mixture which contains between about 1-40 percent wt/vol carbohydrate and about 0.1-15 percent wt/vol nonspecific protein, preferably between about 10-20 percent carbohydrate and about 5-8 percent protein. A preferred carbohydrate/protein mixture comprises about 10 percent mannitol and about 6 percent albumin. The blood or other fluid moves through the filter card by capillary action aided by an absorbent matrix with a high Klemm factor which abuts the filter card. The absorbent matrix and/or filter card can be treated with a wide spectrum of test reagents. The speed, cleanliness, and efficiency of the separation process can be altered by: (a) changing the absolute concentration of the carbohydrate/protein mixture; (b) applying positive or negative pressure to one side of the filter; and/or (c) varying the relative density and pore size of the filter card and absorbent matrix.
NASA Technical Reports Server (NTRS)
Caplin, R. S.; Royer, E. R.
1978-01-01
Attempts are made to provide a total design of a Microbial Load Monitor (MLM) system flight engineering model. Activities include assembly and testing of Sample Receiving and Card Loading Devices (SRCLDs), operator related software, and testing of biological samples in the MLM. Progress was made in assembling SRCLDs with minimal leaks and which operate reliably in the Sample Loading System. Seven operator commands are used to control various aspects of the MLM such as calibrating and reading the incubating reading head, setting the clock and reading time, and status of Card. Testing of the instrument, both in hardware and biologically, was performed. Hardware testing concentrated on SRCLDs. Biological testing covered 66 clinical and seeded samples. Tentative thresholds were set and media performance listed.
Proton Single Event Effects (SEE) Testing of the Myrinet Crossbar Switch and Network Interface Card
NASA Technical Reports Server (NTRS)
Howard, James W., Jr.; LaBel, Kenneth A.; Carts, Martin A.; Stattel, Ronald; Irwin, Timothy L.; Day, John H. (Technical Monitor)
2002-01-01
As part of the Remote Exploration and Experimentation Project (REE), work was performed to do a proton SEE (Single Event Effect) evaluation of the Myricom network protocol system (Myrinet). This testing included the evaluation of the Myrinet crossbar switch and the Network Interface Card (NIC). To this end, two crossbar switch devices and five components in the NIC were exposed to the proton beam at the University of California at Davis Crocker Nuclear Laboratory (CNL).
Design and implementation of reliability evaluation of SAS hard disk based on RAID card
NASA Astrophysics Data System (ADS)
Ren, Shaohua; Han, Sen
2015-10-01
Because of the huge advantage of RAID technology in storage, it has been widely used. However, the question associated with this technology is that the hard disk based on the RAID card can not be queried by Operating System. Therefore how to read the self-information and log data of hard disk has been a problem, while this data is necessary for reliability test of hard disk. In traditional way, this information can be read just suitable for SATA hard disk, but not for SAS hard disk. In this paper, we provide a method by using LSI RAID card's Application Program Interface, communicating with RAID card and analyzing the feedback data to solve the problem. Then we will get the necessary information to assess the SAS hard disk.
A cost-effective add-on-value card-assisted firewall over Taiwan's NHI VPN framework.
Huang, Jyh-Win; Hou, Ting-Wei
2007-06-01
Besides the overall budget for building the infrastructure of a healthcare-service-based virtual private network (VPN) in Taiwan, two issues were considered critical for its acceptance by the country's 17,000 plus medical institutions. One was who was to pay for the network (ADSL or modem) connection fee; the other was who was to pay for the firewall/anti-virus software. This paper addresses the second issue by proposing an efficient freeware firewall, named card-assisted firewall (CAF), for NHI VPN edge-hosts, which is also an add-on-value application of the National Healthcare IC card that every insurant and medical professional has. The innovative concept is that any NHI VPN site (edge-host) can establish diversified secure-authenticated connections with other sites only by an authentication mechanism, which requires a NHI Java card state machine and the Access Control List of the host. It is different from two-factor authentication cards in four ways: (1) a PIN code is not a must; (2) it requires authentication with the remote IC card Data Centre; (3) the NHI cards are already available, no modification is needed, and there is no further cost for the deployment of the cards; (4) although the cards are in the reader, the communication cannot start unless the cards are in the corresponding states; i.e. the states allow communication. An implementation, on a Microsoft Windows XP platform, demonstrated the system's feasibility over an emulation of the NHI VPN framework. It maintained a high line speed, the driver took up 39 KB of disk space, installation was simple, not requiring any extra hardware or software, and the average packet processing time of the CAF driver measured was 0.3084 ms. The average overhead in comparing the Access Control List predefined routing in card, in an FTP testing experiment, was 5.7 micros (receiving) and 8 micros (sending).
NASA Astrophysics Data System (ADS)
Jin, Yu; Liu, Renrong; Zhu, Lixin; Chen, Zhenzhen
2017-11-01
In this paper, an immunochromatographic assay card was developed for the detection of DON in feed and cereals using a novel colloidal gold labeling method. For the colloidal gold immunochromatographic rapid detection (GICD) card, a monoclonal antibody DON-mAb and a goat anti-chicken IgY were drawn on NC membrane as the test line (T line) and the control line (C line) respectively. A gold labeled DON-CBSA conjugate and a gold labeled chicken IgY were sprayed onto the conjugate pad. The GICD card has cut-off levels of 50ng/mL for DON, which is invulnerable to matrix interference, and applicable to a wide range of samples. The GICD detecting results of feed and grain samples were compared with the results of ELISA testing, which showed good consistency.
Use of FTA® classic cards for epigenetic analysis of sperm DNA.
Serra, Olga; Frazzi, Raffaele; Perotti, Alessio; Barusi, Lorenzo; Buschini, Annamaria
2018-02-01
FTA® technologies provide the most reliable method for DNA extraction. Although FTA technologies have been widely used for genetic analysis, there is no literature on their use for epigenetic analysis yet. We present for the first time, a simple method for quantitative methylation assessment based on sperm cells stored on Whatman FTA classic cards. Specifically, elution of seminal DNA from FTA classic cards was successfully tested with an elution buffer and an incubation step in a thermocycler. The eluted DNA was bisulfite converted, amplified by PCR, and a region of interest was pyrosequenced.
Leung, S C; Fung, W K; Wong, K H
1999-01-01
The relative bit density variation graphs of 207 specimen credit cards processed by 12 encoding machines were examined first visually, and then classified by means of hierarchical cluster analysis. Twenty-nine credit cards being treated as 'questioned' samples were tested by way of cluster analysis against 'controls' derived from known encoders. It was found that hierarchical cluster analysis provided a high accuracy of identification with all 29 'questioned' samples classified correctly. On the other hand, although visual comparison of jitter graphs was less discriminating, it was nevertheless capable of giving a reasonably accurate result.
NASA Technical Reports Server (NTRS)
1992-01-01
Technology originating in a NASA-sponsored study of the measurement of microbial growth in zero gravity led to the development of Biomerieux Vitek, Inc.'s VITEK system. VITEK provides a physician with accurate diagnostic information and identifies the most effective medication. Test cards are employed to identify organisms and determine susceptibility to antibiotics. A photo-optical scanner scans the card and monitors changes in the growth of cells contained within the card. There are two configurations - VITEK and VITEK JR as well as VIDAS, a companion system that detects bacteria, viruses, etc. from patient specimens. The company was originally created by McDonnell Douglas, the NASA contractor.
Metacognitive Support Promotes an Effective Use of Instructional Resources in Intelligent Tutoring
ERIC Educational Resources Information Center
Schwonke, Rolf; Ertelt, Anna; Otieno, Christine; Renkl, Alexander; Aleven, Vincent; Salden, Ron J. C. M.
2013-01-01
We tested whether the provision of metacognitive knowledge on how to cope with the complexity of a learning environment improved learning. In an experimental setting, high-school students (N = 60) worked through a computer-based geometry lesson either with or without metacognitive support in the form of a cue card. This cue card encouraged…
Relations as Rules: The Role of Attention in the Dimensional Change Card Sort Task
ERIC Educational Resources Information Center
Honomichl, Ryan D.; Chen, Zhe
2011-01-01
Preschoolers are typically unable to switch sorting rules during the Dimensional Change Card Sort task. One explanation for this phenomenon is attentional inflexibility (Kirkham, Cruess, & Diamond, 2003). In 4 experiments with 3- to 4-year-olds, we tested this hypothesis by examining the influence of dimensional salience on switching performance.…
A Welcomed Intrusion: A Response to Card and Giuliano's Evaluation of a Gifted Program
ERIC Educational Resources Information Center
Warne, Russell T.
2016-01-01
Card and Giuliano conducted a regression discontinuity study in a large Florida school district to investigate the magnitude of academic benefits of the district's gifted program. They found that for children identified as gifted through an intelligence test, the program provided few or no benefits. But children who were admitted to the gifted…
Using a Memory Test to Limit a User to One Account
NASA Astrophysics Data System (ADS)
Conitzer, Vincent
In many Web-based applications, there are incentives for a user to sign up for more than one account, under false names. By doing so, the user can send spam e-mail from an account (which will eventually cause the account to be shut down); distort online ratings by rating multiple times (in particular, she can inflate her own reputation ratings); indefinitely continue using a product with a free trial period; place shill bids on items that she is selling on an auction site; engage in false-name bidding in combinatorial auctions; etc. All of these behaviors are highly undesirable from the perspective of system performance. While CAPTCHAs can prevent a bot from automatically signing up for many accounts, they do not prevent a human from signing up for multiple accounts. It may appear that the only way to prevent the latter is to require the user to provide information that identifies her in the real world (such as a credit card or telephone number), but users are reluctant to give out such information.
Patient health record on a smart card.
Naszlady, A; Naszlady, J
1998-02-01
A validated health questionnaire has been used for the documentation of a patient's history (826 items) and of the findings from physical examination (591 items) in our clinical ward for 25 years. This computerized patient record has been completed in EUCLIDES code (CEN TC/251) for laboratory tests and an ATC and EAN code listing for the names of the drugs permanently required by the patient. In addition, emergency data were also included on an EEPROM chipcard with a 24 kb capacity. The program is written in FOX-PRO language. A group of 5000 chronically ill in-patients received these cards which contain their health data. For security reasons the contents of the smart card is only accessible by a doctor's PIN coded key card. The personalization of each card was carried out in our health center and the depersonalized alphanumeric data were collected for further statistical evaluation. This information served as a basis for a real need assessment of health care and for the calculation of its cost. Code-combined with an optical card, a completely paperless electronic patient record system has been developed containing all three information carriers in medicine: Texts, Curves and Pictures.
The scarcity heuristic impacts reward processing within the medial-frontal cortex.
Williams, Chad C; Saffer, Boaz Y; McCulloch, Robert B; Krigolson, Olave E
2016-05-04
Objects that are rare are often perceived to be inherently more valuable than objects that are abundant - a bias brought about in part by the scarcity heuristic. In the present study, we sought to test whether perception of rarity impacted reward evaluation within the human medial-frontal cortex. Here, participants played a gambling game in which they flipped rare and abundant 'cards' on a computer screen to win financial rewards while electroencephalographic data were recorded. Unbeknownst to participants, reward outcome and frequency was random and equivalent for both rare and abundant cards; thus, only a perception of scarcity was true. Analysis of the electroencephalographic data indicated that the P300 component of the event-related brain potential differed in amplitude for wins and losses following the selection of rare cards, but not following the selection of abundant cards. Importantly, then, we found that the perception of card rarity impacted reward processing even though reward feedback was independent of and subsequent to card selection. Our data indicate a top-down influence of the scarcity heuristic on reward evaluation, and specifically the processing of reward magnitude, within the human medial-frontal cortex.
Commercial products to preserve specimens for tuberculosis diagnosis: a systematic review.
Reeve, B W P; McFall, S M; Song, R; Warren, R; Steingart, K R; Theron, G
2018-07-01
Eliminating tuberculosis in high-burden settings requires improved diagnostic capacity. Important tests such as Xpert® MTB/RIF and culture are often performed at centralised laboratories that are geographically distant from the point of specimen collection. Preserving specimen integrity during transportation, which could affect test performance, is challenging. To conduct a systematic review of commercial products for specimen preservation for a World Health Organization technical consultation. Databases were searched up to January 2018. Methodological quality was assessed using Quality Assessment of Technical Studies, a new technical study quality-appraisal tool, and Quality Assessment of Diagnostic Accuracy Studies-2. Studies were analysed descriptively in terms of the different products, study designs and diagnostic strategies used. Four products were identified from 16 studies: PrimeStore-Molecular-Transport-Medium (PS-MTM), FTA card, GENO•CARD (all for nucleic acid amplification tests [NAATs]) and OMNIgene•SPUTUM (OMS; culture, NAATs). PS-MTM, but not FTA card or GENO•CARD, rendered Mycobacterium tuberculosis non-culturable. OMS reduced Löwenstein-Jensen but not MGIT™ 960™ contamination, led to delayed MGIT time-to-positivity, resulted in Xpert performance similar to cold chain-transported untreated specimens, and obviated the need for N-acetyl-L-cysteine-sodium hydroxide decontamination. Data from paucibacillary specimens were limited. Evidence that a cold chain improves culture was mixed and absent for Xpert. The effect of the product alone could be discerned in only four studies. Limited evidence suggests that transport products result in test performance comparable to that seen in cold chain-transported specimens.
Chen, Feng; Zhang, Xi; Wang, Shaoming; Hu, Shangying; Chen, Wen; Zhao, Fanghui; He, Wei; Zhang, Yuqing; Qiao, Youlin
2015-02-01
To evaluate the effectiveness of FTA Elute® Cartridge (GE healthcare, Kent, UK) in combination with hybrid capture 2 (HC2) testing for cervical cancer screening. From May to June 2012, 412 women aged 25 to 65 years in Jiangxi Tonggu were enrolled in the study. We used pathological outcome as the gold standard, and the accuracy of the FTA card in combination with HC2 testing was investigated from both physician- and self-sampling, respectively. Physician sampling using the FTA card in combination with HC2 testing showed a comparable sensitivity (12/13) with the liquid based medium, but a higher specificity 69.5% (266/383) vs (77.8%, 298/383) (P < 0.001).When self sampling method was used, the sensitivity and specificity of using the FTA card in combination with HC2 testing with liquid based medium was 10/13 vs 8/13(P = 0.625) and (62.3%, 238/382) vs (75.7%, 289/382) (P < 0.001). The agreement of detection results for HC2 between FTA and liquid-based sampling medium was 86.1% (340/395) and 79.5% (314/395). For physician-collected samples used for HC2 testing to detect CIN2+, the accuracy of the FTA card was superior to that of the liquid-based medium (area under the receiver operating characteristic curve (AUC) = 0.898, 95%CI:0.838-0.958). FTA Elute® cartridge in combination with HC2 testing is a promising method of specimen transport for cervical cancer screening programs with a good precision.With further optimization, it could become an effective method for cervical cancer screening in various economic levels of areas.
Use of FTA sampling cards for molecular detection of avian influenza virus in wild birds.
Keeler, Shamus P; Ferro, Pamela J; Brown, Justin D; Fang, Xingwang; El-Attrache, John; Poulson, Rebecca; Jackwood, Mark W; Stallknecht, David E
2012-03-01
Current avian influenza (AI) virus surveillance programs involving wild birds rely on sample collection methods that require refrigeration or low temperature freezing to maintain sample integrity for virus isolation and/or reverse-transcriptase (RT) PCR. Maintaining the cold chain is critical for the success of these diagnostic assays but is not always possible under field conditions. The aim of this study was to test the utility of Finders Technology Associates (FTA) cards for reliable detection of AI virus from cloacal and oropharyngeal swabs of wild birds. The minimum detectable titer was determined, and the effect of room temperature storage was evaluated experimentally using multiple egg-propagated stock viruses (n = 6). Using real time RT-PCR, we compared results from paired cloacal swab and samples collected on FTA cards from both experimentally infected mallards (Anasplatyrhynchos) and hunter-harvested waterfowl sampled along the Texas Gulf Coast. Based on the laboratory trials, the average minimal detectable viral titer was determined to be 1 x 10(4.7) median embryo infectious dose (EID50)/ml (range: 1 x 10(4.3) to 1 x 10(5.4) EID50/ml), and viral RNA was consistently detectable on the FTA cards for a minimum of 20 days and up to 30 days for most subtypes at room temperature (23 C) storage. Real-time RT-PCR of samples collected using the FTA cards showed fair to good agreement in live birds when compared with both real-time RT-PCR and virus isolation of swabs. AI virus detection rates in samples from several wild bird species were higher when samples were collected using the FTA cards compared with cloacal swabs. These results suggest that FTA cards can be used as an alternative sample collection method when traditional surveillance methods are not possible, especially in avian populations that have historically received limited testing or situations in which field conditions limit the ability to properly store or ship swab samples.
NOD2/CARD15 mutations and the risk of reoperation in patients with Crohns disease.
Martínek, L; Kupka, T; Simova, J; Klvaňa, P; Bojková, M; Uvírová, M; Dítě, P; Dvorackova, J; Hoch, J; Zonca, P
2015-06-01
Three NOD2/CARD15 gene variants (3020insC, R702W, G908R) have been identified as genetic risk factors for Crohns disease patients. However the diagnostic and therapeutic relevance for clinical practice remains limited. The aim of this study was to evaluate the association between these variants, the risk of reoperation and disease phenotype. In 76 Crohns disease patients (41 female, 35 male) with a minimum 5 year follow-up, three polymorphisms of the NOD2/CARD15 gene (R702W, G908R, 3020insC) were tested. Detailed clinical and medical history including surgical procedures and reoperations were obtained by reviewing the medical charts and completed prospectively. Association between the need for reoperation, disease phenotypes and gene variants were analyzed. 24 patients (32%) showed at least one NOD2/CARD15 mutation. 25 patients (33%) required reoperation, 51 (67%) represented the control group. The expected trend that patients with NOD2/CARD15 variants have a higher frequency of reoperations was not confirmed to a level of statistical significance (p=0.2688). Two of the four patients (50%) with the 3020insC variant required further surgery. We did not confirm any association between NOD2/CARD15 mutations and age at diagnosis (p=0.4356), behavior (p=0.6610), or localization (p=0.4747) according to the Montreal classification. NOD2/CARD15 polymorphisms did not significantly affect the reoperation rate. Homozygosity for the 3020insC variant in the NOD2/CARD15 gene is associated with a high risk of reoperation. NOD2/CARD15 gene variants are not significantly associated with specific disease phenotypes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bharoto,; Suparno, Nadi; Putra, Edy Giri Rachman
In 2005, the main computer for data acquisition and control system of Small-angle Neutron Scattering (SANS) BATAN Spectrometer (SMARTer) was replaced since it halted to operate the spectrometer. According to this replacement, the new software for data acquisition and control system has been developed in-house. Visual Basic programming language is used in developing the software. In the last two years, many developments have been made both in the hardware and also the software to conduct the experiment is more effective and efficient. Lately, the previous motor controller card (ISA Card) was replaced with the programmable motor controller card (PCI Card)more » for driving one motor of position sensitive detector (PSD), eight motors of four collimators, and six motors of six pinhole discs. This new control system software makes all motors can be moved simultaneously, then it reduces significantly the consuming time of setting up the instrument before running the experiment. Along with that development, the new data acquisition software under MS Windows operating system is also developed to drive a beam stopper in X-Y directions as well as to read the equipment status such as position of the collimators and PSD, to acquire neutron counts on monitor and PSD detectors, and also to manage 12 samples position automatically. A timer object which is set in one second to read the equipment status via serial port of the computer (RS232C), and general purpose interface board (GPIB) for reading the total counts of each pixel of the PSD from histogram memory was used in this new software. The experiment result displayed in real time on the main window, and the data is saved in the special format for further data reduction and analysis. The new software has been implemented and performed for experiment using a preset count or preset time mode for absolute scattering intensity method.« less
NASA Astrophysics Data System (ADS)
Bharoto, Suparno, Nadi; Putra, Edy Giri Rachman
2015-04-01
In 2005, the main computer for data acquisition and control system of Small-angle Neutron Scattering (SANS) BATAN Spectrometer (SMARTer) was replaced since it halted to operate the spectrometer. According to this replacement, the new software for data acquisition and control system has been developed in-house. Visual Basic programming language is used in developing the software. In the last two years, many developments have been made both in the hardware and also the software to conduct the experiment is more effective and efficient. Lately, the previous motor controller card (ISA Card) was replaced with the programmable motor controller card (PCI Card) for driving one motor of position sensitive detector (PSD), eight motors of four collimators, and six motors of six pinhole discs. This new control system software makes all motors can be moved simultaneously, then it reduces significantly the consuming time of setting up the instrument before running the experiment. Along with that development, the new data acquisition software under MS Windows operating system is also developed to drive a beam stopper in X-Y directions as well as to read the equipment status such as position of the collimators and PSD, to acquire neutron counts on monitor and PSD detectors, and also to manage 12 samples position automatically. A timer object which is set in one second to read the equipment status via serial port of the computer (RS232C), and general purpose interface board (GPIB) for reading the total counts of each pixel of the PSD from histogram memory was used in this new software. The experiment result displayed in real time on the main window, and the data is saved in the special format for further data reduction and analysis. The new software has been implemented and performed for experiment using a preset count or preset time mode for absolute scattering intensity method.
Lario, Sergio; Ramírez-Lázaro, María José; Montserrat, Antònia; Quílez, María Elisa; Junquera, Félix; Martínez-Bauer, Eva; Sanfeliu, Isabel; Brullet, Enric; Campo, Rafael; Segura, Ferran; Calvet, Xavier
2016-06-01
Immunochromatographic tests need to be improved in order to enhance their reliability. Recently, several new kits have appeared on the market. The objective was to evaluate the diagnostic accuracy of three monoclonal rapid stool tests - the new Uni-Gold™ H.pylori Antigen (Trinity Biotech, Ireland), the RAPID Hp StAR (Oxoid Ltd., UK) and the ImmunoCard STAT! HpSA (Meridian Diagnostics, USA) - for detecting H. pylori infection prior to eradication treatment. Diagnostic accuracy (sensitivity and specificity) and reliability (concordance between observers) were evaluated in 250 untreated consecutive dyspeptic patients. The gold standard for diagnosing H. pylori infection was defined as the concordance of two or more of rapid urease test (RUT), histopathology and urease breath test (UBT) or positive culture in isolation. Readings of immunochromatographic tests were performed by two different observers. Sensitivity, specificity, positive and negative predictive values and 95% confidence intervals were calculated. Sensitivity and specificity were compared using the McNemar test. The three tests showed a good correlation, with Kappa values>0.9. RAPID Hp StAR had a sensitivity of 91%-92% and a specificity ranging from 77% to 85%. Its sensitivity was higher than that of Uni-Gold™ H.pylori Antigen and ImmunoCard STAT! HpSA (p<0.01). Uni-Gold™ H.pylori Antigen kit showed a sensitivity of 83%, similar to ImmunoCard STAT! HpSA. Specificity of Uni-Gold™ H.pylori Antigen approached 90% (87-89%) and was superior to that of RAPID Hp StAR (p<0.01). Uni-Gold™ H.pylori Antigen and ImmunoCard STAT! HpSA present similar levels of diagnostic accuracy. RAPID Hp StAR was the most sensitive but less reliable of the three immunochromatographic stool tests. None are as accurate and reliable as UBT, RUT and histology. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Data-nonintrusive photonics-based credit card verifier with a low false rejection rate.
Sumriddetchkajorn, Sarun; Intaravanne, Yuttana
2010-02-10
We propose and experimentally demonstrate a noninvasive credit card verifier with a low false rejection rate (FRR). Our key idea is based on the use of three broadband light sources in our data-nonintrusive photonics-based credit card verifier structure, where spectral components of the embossed hologram images are registered as red, green, and blue. In this case, nine distinguishable variables are generated for a feed-forward neural network (FFNN). In addition, we investigate the center of mass of the image histogram projected onto the x axis (I(color)), making our system more tolerant of the intensity fluctuation of the light source. We also reduce the unwanted signals on each hologram image by simply dividing the hologram image into three zones and then calculating their corresponding I(color) values for red, green, and blue bands. With our proposed concepts, we implement our field test prototype in which three broadband white light light-emitting diodes (LEDs), a two-dimensional digital color camera, and a four-layer FFNN are used. Based on 249 genuine credit cards and 258 counterfeit credit cards, we find that the average of differences in I(color) values between genuine and counterfeit credit cards is improved by 1.5 times and up to 13.7 times. In this case, we can effectively verify credit cards with a very low FRR of 0.79%.
Detection of multidrug-resistant tuberculosis from stored DNA Samples: A multicenter study.
Rabodoarivelo, Marie Sylvianne; Brandao, A; Cergole Novella, M C; C Bombonatte, A G; Imperiale, B; Rakotosamimanana, N; Morcillo, N; Rasolofo, V; Palomino, J C; Martin, A
2018-01-01
In low-income countries, rapid detection of tuberculosis (TB) drug resistance is often restricted by the difficulties of transporting and storing sputum samples from remote health centers to the reference laboratories where molecular tests are available. The aim of this study was to evaluate the performance of four transport and storage systems for molecular detection of rifampicin (RIF) and isoniazid (INH) resistance. This was a multicenter study. Molecular detection of RIF and INH resistance was performed directly from smear-positive TB sputa spotted on a slide, FTA card, GenoCard, and ethanol using the Genotype MTBDRplus assay. The performance of the DNA extraction method from each storage support to detect drug resistance was assessed by calculating their sensitivity and specificity compared to the phenotypic method. From all sites, the overall sensitivity and specificity for RIF-resistance detection was 88% and 85%, respectively, for slides, 86% and 92%, respectively, for GenoCard, 87% and 89%, respectively, for FTA card, and 88% and 92%, respectively, for ethanol. For INH-resistance detection, the overall sensitivity and specificity was 82% and 90%, respectively, for slides, 85% and 96%, respectively, for GenoCard, 86% and 92%, respectively, for FTA card, and 86% and 94%, respectively, for ethanol. Smear slides and filter cards showed to be very useful tools to facilitate DNA extraction from sputum samples with the potential to accelerate the detection of drug resistance in remote areas.
Evaluation of a New Patient Record System Using the Optical Card
Brown, J.H.U.; Vallbona, Carlos; Shoda, Junji; Albin, Jean
1989-01-01
A new form of patient record has been devised in which a laser imprinted card is coupled to a p.c. for data input and output. Entry of data is simple and recall of any datum requires only a keystroke. Any part of the data can be readily accessed through a software system which encompasses a variety of screens and menus to summarize and combine data. The complete system has been under test in a community health clinic and at NASA and results to date are satisfactory. Preliminary evaluation indicates that the system has no hardware problems, that the software is suitable for the purpose, that patients carry the card and return with it at succeeding visits, that physicians accept that card for a medical record and are pleased with the speed of access and the organization of the data.
Code of Federal Regulations, 2013 CFR
2013-01-01
... water consumption of automatic commercial ice makers. 431.134 Section 431.134 Energy DEPARTMENT OF... Automatic Commercial Ice Makers Test Procedures § 431.134 Uniform test methods for the measurement of energy and water consumption of automatic commercial ice makers. (a) Scope. This section provides the test...
Code of Federal Regulations, 2014 CFR
2014-01-01
... water consumption of automatic commercial ice makers. 431.134 Section 431.134 Energy DEPARTMENT OF... Automatic Commercial Ice Makers Test Procedures § 431.134 Uniform test methods for the measurement of energy and water consumption of automatic commercial ice makers. (a) Scope. This section provides the test...
The design of automatic software testing module for civil aviation information system
NASA Astrophysics Data System (ADS)
Qi, Qi; Sun, Yang
2018-05-01
In this paper, the practical innovation design is carried out according to the urgent needs of the automatic testing module of civil aviation information system. Firstly, the background and significance of the automatic testing module of civil aviation information system is expounded, and the current research status of automatic testing module and the advantages and disadvantages of related software are analyzed. Then, from the three aspects of macro demand, module functional requirement and module nonfunctional demand, we further study the needs of automatic testing module of civil aviation information system. Finally, from the four aspects of module structure, module core function, database and security, we have made an innovative plan for the automatic testing module of civil aviation information system.
A 16-Channel Nonparametric Spike Detection ASIC Based on EC-PC Decomposition.
Wu, Tong; Xu, Jian; Lian, Yong; Khalili, Azam; Rastegarnia, Amir; Guan, Cuntai; Yang, Zhi
2016-02-01
In extracellular neural recording experiments, detecting neural spikes is an important step for reliable information decoding. A successful implementation in integrated circuits can achieve substantial data volume reduction, potentially enabling a wireless operation and closed-loop system. In this paper, we report a 16-channel neural spike detection chip based on a customized spike detection method named as exponential component-polynomial component (EC-PC) algorithm. This algorithm features a reliable prediction of spikes by applying a probability threshold. The chip takes raw data as input and outputs three data streams simultaneously: field potentials, band-pass filtered neural data, and spiking probability maps. The algorithm parameters are on-chip configured automatically based on input data, which avoids manual parameter tuning. The chip has been tested with both in vivo experiments for functional verification and bench-top experiments for quantitative performance assessment. The system has a total power consumption of 1.36 mW and occupies an area of 6.71 mm (2) for 16 channels. When tested on synthesized datasets with spikes and noise segments extracted from in vivo preparations and scaled according to required precisions, the chip outperforms other detectors. A credit card sized prototype board is developed to provide power and data management through a USB port.
Norman, Marc A; Moore, David J; Taylor, Michael; Franklin, Donald; Cysique, Lucette; Ake, Chris; Lazarretto, Deborah; Vaida, Florin; Heaton, Robert K
2011-08-01
Memory and executive functioning are two important components of clinical neuropsychological (NP) practice and research. Multiple demographic factors are known to affect performance differentially on most NP tests, but adequate normative corrections, inclusive of race/ethnicity, are not available for many widely used instruments. This study compared demographic contributions for widely used tests of verbal and visual learning and memory (Brief Visual Memory Test-Revised, Hopkins Verbal Memory Test-Revised) and executive functioning (Stroop Color and Word Test, Wisconsin Card Sorting Test-64) in groups of healthy Caucasians (n = 143) and African Americans (n = 103). Demographic factors of age, education, gender, and race/ethnicity were found to be significant factors on some indices of all four tests. The magnitude of demographic contributions (especially age) was greater for African Americans than for Caucasians on most measures. New, demographically corrected T-score formulas were calculated for each race/ethnicity. The rates of NP impairment using previously published normative standards significantly overestimated NP impairment in African Americans. Utilizing the new demographic corrections developed and presented herein, NP impairment rates were comparable between the two race/ethnicities and were unrelated to the other demographic characteristics (age, education, gender) in either race/ethnicity group. Findings support the need to consider extended demographic contributions to neuropsychological test performance in clinical and research settings.
An Approach to Near Field Data Selection in Radio Frequency Identification
NASA Astrophysics Data System (ADS)
Winkworth, Robert D.
Personal identification is needed in many civil activities, and the common identification cards, such as a driver's license, have become the standard document de facto. Radio frequency identification has complicated this matter. Unlike their printed predecessors, contemporary RFID cards lack a practical way for users to control access to their individual fields of data. This leaves them more available to unauthorized parties, and more prone to abuse. Here, then was undertaken a means to test a novel RFID card technology that allows overlays to be used for reliable, reversible data access settings. Similar to other proposed switching mechanisms, it offers advantages that may greatly improve outcomes. RFID use is increasing in identity documents such as drivers' licenses and passports, and with it concern over the theft of personal information, which can enable unauthorized tracking or fraud. Effort put into designing a strong foundation technology now may allow for widespread development on them later. In this dissertation, such a technology was designed and constructed, to drive the central thesis that selective detuning could serve as a feasible, reliable mechanism. The concept had been illustrated effective in limiting access to all fields simultaneously before, and was here effective in limiting access to specific fields selectively. A novel card was produced in familiar dimensions, with an intuitive interface by which users may conceal the visible print of the card to conceal the wireless emissions it allows. A discussion was included of similar technologies, involving capacitive switching, that could further improve the outcomes if such a product were put to large-scale commercial fabrication. The card prototype was put to a battery of laboratory tests to measure the degree of independence between data fields and the reliability of the switching mechanism when used under realistically variable coverage, demonstrating statistically consistent performance in both. The success rate of RFID card read operations, which are already greater than 99.9%, were exceeded by the success rate of selection using the featured technology. With controls in place for the most influential factors related to card readability (namely the distance from the reader antennas and the orientation of the card antenna with respect to them), the card was shown to completely resist data acquisition from unauthorized fields while allowing unimpeded access to authorized fields, even after thousands of varied attempts. The effect was proven to be temporary and reversible. User intervention allowed for the switching to occur in a matter of seconds by sliding a conductive sleeve or applying tape to regions of the card. Strategies for widespread implementation were discussed, emphasizing factors that included cost, durability, size, simplicity, and familiarity, all of which arise in card management decisions for common state and national identification such as a driver's license. The relationship between the card and external database systems was detailed, as no such identification document could function in isolation. A practical solution involving it will include details of how multiple fields will be written to the card and separated sufficiently in external databases so as to allow for user-directed selection of data field disclosure. Opportunities for implementation in corporate and academic environments were discussed, along with the ways in which this technology could invite further investigation.
Selective, sustained, and shift in attention in patients with diagnoses of schizophrenia.
Hagh-Shenas, H; Toobai, S; Makaremi, A
2002-12-01
Attentional deficits are a prominent aspect of cognitive dysfunction in schizophrenia. The present study was designed to investigate attention deficit in a group of patients with diagnosis of schizophrenia. According to the segmental set theory suggested by Hogarty and Flesher, three aspects of attention problems, selective, sustained, and shift in attention, were studied. The 30 patients hospitalized on three psychiatric wards at Shiraz and Isfahan and 30 normal healthy subjects matched for age, sex, and years of education were administered a computerized Continuous Performance Test, Stroop Color-word Test, and Wisconsin Card Sorting test. Analysis showed patients performed more poorly than control subjects on measured aspects of attention. The acute/chronic classification did not predict differences in attention scores between subtypes of schizophrenia, while the positive/negative classification did. Paranoid, undifferentiated, and residual groups by subtypes of schizophrenia showed similar performance on the Continuous Performance Test, but were significantly different on errors on the Wisconsin Card Sorting test and on reaction time to Stroop stimuli in the incongruent color-word condition. Patients with paranoid diagnosis performed better than other subtypes on these tasks. Present results suggest that the Continuous Performance Test is valuable for differentiating of schizophrenia spectrum disorder, while scores on Stroop and Wisconsin card sorting may have better diagnostic value for differentiating subtypes of the disorder.
Ribeiro, Madelon Novato; Pimentel, Maria Inês Fernandes; Schubach, Armando de Oliveira; Oliveira, Raquel de Vasconcellos Carvalhães de; Teixeira, José Liporage; Leite, Madson Pedro da Silva; Fonseca, Monique; Santos, Ginelza Peres Lima dos; Salgueiro, Mariza Matos; Ferreira e Vasconcellos, Erica de Camargo; Lyra, Marcelo Rosandiski; Saheki, Mauricio Naoto; Valete-Rosalino, Claudia Maria
2014-01-01
The favorable outcome of the treatment of a disease is influenced by the adherence to therapy. Our objective was to assess factors associated with adherence to treatment of patients included in a clinical trial of equivalence between the standard and alternative treatment schemes with meglumine antimoniate (MA) in the treatment of cutaneous leishmaniasis (CL), in the state of Rio de Janeiro. Between 2008 and 2011, 57 patients with CL were interviewed using a questionnaire to collect socioeconomic data. The following methods were used for adherence monitoring: counting of vial surplus, monitoring card, Morisky test and modified Morisky test (without the question regarding the schedule); we observed 82.1% (vial return), 86.0% (monitoring card), 66.7% (Morisky test) and 86.0% (modified Morisky test) adherence. There was a strong correlation between the method of vial counting and the monitoring card and modified Morisky test. A significant association was observed between greater adherence to treatment and low dose of MA, as well as with a lower number of people sleeping in the same room. We recommend the use of the modified Morisky test to assess adherence to treatment of CL with MA, because it is a simple method and with a good performance, when compared to other methods.
ERIC Educational Resources Information Center
Gutierrez, Arnel F.
2014-01-01
The complex concepts and vocabulary of biology classes discourage many students. In this study, a pretest-posttest model was used to test the effectiveness of an educational card game in reinforcing biological concepts in comparison with traditional teaching methods. The subjects of this study were two biology classes at Bulacan State…
Cortes, Aneg L; Montiel, Enrique R; Gimeno, Isabel M
2009-12-01
The use of Flinders Technology Associates (FTA) filter cards to quantify Marek's disease virus (MDV) DNA for the diagnosis of Marek's disease (MD) and to monitor MD vaccines was evaluated. Samples of blood (43), solid tumors (14), and feather pulp (FP; 36) collected fresh and in FTA cards were analyzed. MDV DNA load was quantified by real-time PCR. Threshold cycle (Ct) ratios were calculated for each sample by dividing the Ct value of the internal control gene (glyceraldehyde-3-phosphate dehydrogenase) by the Ct value of the MDV gene. Statistically significant correlation (P < 0.05) within Ct ratios was detected between samples collected fresh and in FTA cards by using Pearson's correlation test. Load of serotype 1 MDV DNA was quantified in 24 FP, 14 solid tumor, and 43 blood samples. There was a statistically significant correlation between FP (r = 0.95), solid tumor (r = 0.94), and blood (r = 0.9) samples collected fresh and in FTA cards. Load of serotype 2 MDV DNA was quantified in 17 FP samples, and the correlation between samples collected fresh and in FTA cards was also statistically significant (Pearson's coefficient, r = 0.96); load of serotype 3 MDV DNA was quantified in 36 FP samples, and correlation between samples taken fresh and in FTA cards was also statistically significant (r = 0.84). MDV DNA samples extracted 3 days (t0) and 8 months after collection (t1) were used to evaluate the stability of MDV DNA in archived samples collected in FTA cards. A statistically significant correlation was found for serotype 1 (r = 0.96), serotype 2 (r = 1), and serotype 3 (r = 0.9). The results show that FTA cards are an excellent media to collect, transport, and archive samples for MD diagnosis and to monitor MD vaccines. In addition, FTA cards are widely available, inexpensive, and adequate for the shipment of samples nationally and internationally.
Excimer PRK testing in the clinic
NASA Astrophysics Data System (ADS)
Forrest, Gary T.
1994-06-01
Testing of the excimer lasers used in PRK requires special considerations in terms of ease of use, day-to-day reliability, and high resolution to see details of beam interference effects. SensorPhysics employs a patented photochromic material on a polyester substrate to record permanent, instant records of the laser and laser system output. Since each SensorCard is used only once concerns about detection device deterioration are not an issue. The SensorCards have a demonstrated resolving power on the order of 0.1 micrometers . A small, portable reading device is used to convert the SensorCard optical density to a mJ/cm2 value. Special software also measures beam uniformity to +/- 1% to provide both qualitative and quantitative analysis. Results of use in clinic environments will be presented. In particular detection of exposure `islands' will be demonstrated. The techniques employed are similar to those we developed for UV laser micromachining and lithography four years ago.
de Cueto, Marina; Ceballos, Esther; Martinez-Martinez, Luis; Perea, Evelio J.; Pascual, Alvaro
2004-01-01
In order to further decrease the time lapse between initial inoculation of blood culture media and the reporting of results of identification and antimicrobial susceptibility tests for microorganisms causing bacteremia, we performed a prospective study in which specially processed fluid from positive blood culture bottles from Bactec 9240 (Becton Dickinson, Cockeysville, Md.) containing aerobic media were directly inoculated into Vitek 2 system cards (bio-Mérieux, France). Organism identification and susceptibility results were compared with those obtained from cards inoculated with a standardized bacterial suspension obtained following subculture to agar; 100 consecutive positive monomicrobic blood cultures, consisting of 50 gram-negative rods and 50 gram-positive cocci, were included in the study. For gram-negative organisms, 31 of the 50 (62%) showed complete agreement with the standard method for species identification, while none of the 50 gram-positive cocci were correctly identified by the direct method. For gram-negative rods, there were 50% categorical agreements between the direct and standard methods for all drugs tested. The very major error rate was 2.4%, and the major error rate was 0.6%. The overall error rate for gram-negatives was 6.6%. Complete agreement in clinical categories of all antimicrobial agents evaluated was obtained for 19 of 50 (38%) gram-positive cocci evaluated; the overall error rate was 8.4%, with 2.8% minor errors, 2.4% major errors, and 3.2% very major errors. These findings suggest that the Vitek 2 cards inoculated directly from positive Bactec 9240 bottles do not provide acceptable bacterial identification or susceptibility testing in comparison with corresponding cards tested by a standard method. PMID:15297523
NASA Astrophysics Data System (ADS)
Bayharti; Iswendi, I.; Arifin, M. N.
2018-04-01
The purpose of this research was to produce a chemistry game card as an instructional media in the subject of naming chemical compounds and determine the degree of validity and practicality of instructional media produced. Type of this research was Research and Development (R&D) that produced a product. The development model used was4-D model which comprises four stages incuding: (1) define, (2) design, (3) develop, and (4) disseminate. This research was restricted at the development stage. Chemistry game card developed was validated by seven validators and practicality was tested to class X6 students of SMAN 5 Padang. Instrument of this research is questionnair that consist of validity sheet and practicality sheet. Technique in collection data was done by distributing questionnaire to the validators, chemistry teachers, and students. The data were analyzed by using formula Cohen’s Kappa. Based on data analysis, validity of chemistry game card was0.87 with category highly valid and practicality of chemistry game card was 0.91 with category highly practice.
Barreiro-de-Acosta, M; Mendoza, J L; Lana, R; Domínguez-Muñoz, J E; Díaz-Rubio, M
2010-05-01
Crohn's disease (CD) is a genetically complex disease in which both genetic susceptibility and environmental factors play key roles in the development of the disorder. NOD2/CARD15 mutations are associated with CD. NOD2 encodes for a protein that is an intracellular receptor for a bacterial product (muramyl dipeptide), though the exact functional consequences of these mutations remain the subject of debate. NOD2/CARD15 mutations are associated with ileal CD, with stricturing behavior, and possibly with a more complicated course of CD. NOD2/CARD15 mutations associated with CD have demonstrated heterogeneity across ethnicities and populations throughout the world, with regional variations across Europe and Spain. However, "NOD2/CARD15 testing" is not yet ready for use in the clinical setting. One of the reasons is that we know that these genetic variants increase the risk of disease only marginally, and many healthy individuals carry the risk alleles, at present it is not recommended to screen first-degree relatives, because we do not have the ability to prevent the disease at the present time.
Time and resource limits on working memory: cross-age consistency in counting span performance.
Ransdell, Sarah; Hecht, Steven
2003-12-01
This longitudinal study separated resource demand effects from those of retention interval in a counting span task among 100 children tested in grade 2 and again in grades 3 and 4. A last card large counting span condition had an equivalent memory load to a last card small, but the last card large required holding the count over a longer retention interval. In all three waves of assessment, the last card large condition was found to be less accurate than the last card small. A model predicting reading comprehension showed that age was a significant predictor when entered first accounting for 26% of the variance, but counting span accounted for a further 22% of the variance. Span at Wave 1 accounted for significant unique variance at Wave 2 and at Wave 3. Results were similar for math calculation with age accounting for 31% of the variance and counting span accounting for a further 34% of the variance. Span at Wave 1 explained unique variance in math at Wave 2 and at Wave 3.
Removal of anti-Stokes emission background in STED microscopy by FPGA-based synchronous detection
NASA Astrophysics Data System (ADS)
Castello, M.; Tortarolo, G.; Coto Hernández, I.; Deguchi, T.; Diaspro, A.; Vicidomini, G.
2017-05-01
In stimulated emission depletion (STED) microscopy, the role of the STED beam is to de-excite, via stimulated emission, the fluorophores that have been previously excited by the excitation beam. This condition, together with specific beam intensity distributions, allows obtaining true sub-diffraction spatial resolution images. However, if the STED beam has a non-negligible probability to excite the fluorophores, a strong fluorescent background signal (anti-Stokes emission) reduces the effective resolution. For STED scanning microscopy, different synchronous detection methods have been proposed to remove this anti-Stokes emission background and recover the resolution. However, every method works only for a specific STED microscopy implementation. Here we present a user-friendly synchronous detection method compatible with any STED scanning microscope. It exploits a data acquisition (DAQ) card based on a field-programmable gate array (FPGA), which is progressively used in STED microscopy. In essence, the FPGA-based DAQ card synchronizes the fluorescent signal registration, the beam deflection, and the excitation beam interruption, providing a fully automatic pixel-by-pixel synchronous detection method. We validate the proposed method in both continuous wave and pulsed STED microscope systems.
Podjarny, Gal; Kamawar, Deepthi; Andrews, Katherine
2017-07-01
Most executive function research examining preschoolers' cognitive flexibility, the ability to think about something in more than one way, has focused on preschoolers' facility for sequentially switching their attention from one dimension to another (e.g., sorting bivalent cards first by color and then by shape). We know very little about preschoolers' ability to coordinate more than one dimension simultaneously (concurrent cognitive flexibility). Here we report on a new task, the Multidimensional Card Selection Task, which was designed to measure children's ability to consider two dimensions, and then three dimensions, concurrently (e.g., shape and size, and then shape, size, and color). More than half of the preschoolers in our sample of 107 (50 3-year-olds and 57 4-year-olds) could coordinate three dimensions simultaneously and consistently across three test trials. Furthermore, performance on the Multidimensional Card Selection Task was related, but not identical, to performance on other cognitive tasks, including a widely used measure of switching cognitive flexibility (the Dimensional Change Card Sort). The Multidimensional Card Selection Task provides a new way to measure concurrent cognitive flexibility in preschoolers, and opens another avenue for exploring the emergence of early cognitive flexibility development. Copyright © 2017 Elsevier Inc. All rights reserved.
Design of a motion JPEG (M/JPEG) adapter card
NASA Astrophysics Data System (ADS)
Lee, D. H.; Sudharsanan, Subramania I.
1994-05-01
In this paper we describe a design of a high performance JPEG (Joint Photographic Experts Group) Micro Channel adapter card. The card, tested on a range of PS/2 platforms (models 50 to 95), can complete JPEG operations on a 640 by 240 pixel image within 1/60 of a second, thus enabling real-time capture and display of high quality digital video. The card accepts digital pixels for either a YUV 4:2:2 or an RGB 4:4:4 pixel bus and has been shown to handle up to 2.05 MBytes/second of compressed data. The compressed data is transmitted to a host memory area by Direct Memory Access operations. The card uses a single C-Cube's CL550 JPEG processor that complies with the baseline JPEG. We give broad descriptions of the hardware that controls the video interface, CL550, and the system interface. Some critical design points that enhance the overall performance of the M/JPEG systems are pointed out. The control of the adapter card is achieved by an interrupt driven software that runs under DOS. The software performs a variety of tasks that include change of color space (RGB or YUV), change of quantization and Huffman tables, odd and even field control and some diagnostic operations.
Code of Federal Regulations, 2011 CFR
2011-01-01
... consumption and water consumption of automatic commercial ice makers. 431.134 Section 431.134 Energy... EQUIPMENT Automatic Commercial Ice Makers Test Procedures § 431.134 Uniform test methods for the measurement of energy consumption and water consumption of automatic commercial ice makers. (a) Scope. This...
Downs, Jennifer A.; Corstjens, Paul L.A.M.; Mngara, Julius; Lutonja, Peter; Isingo, Raphael; Urassa, Mark; Kornelis, Dieuwke; van Dam, Govert J.
2015-01-01
Circulating Anodic Antigen (CAA) testing is a powerful, increasingly-used tool for diagnosis of active schistosome infection. We sought to determine the feasibility and reliability of measuring CAA in blood spots collected on Whatman 903 Protein Saver cards, which are the predominant filter papers used worldwide for dried blood spot (DBS) research and clinical care. CAA was eluted from blood spots collected from 19 individuals onto Whatman 903 cards in Mwanza, Tanzania, and the assay was optimized to achieve CAA ratios comparable to those obtained from the spots’ corresponding serum samples. The optimized assay was then used to determine the correlation of serum samples (n=16) with DBS from cards that had been stored for 8 years at ambient temperature.Using a DBS volume equivalent to approximately four times the quantity of serum, CAA testing in DBS had a sensitivity of 76% and a specificity of 79% compared to CAA testing in serum. CAA testing was reliable in samples eluted from Whatman 903 cards that had been stored for 8 years at ambient temperature. The overall kappa coefficient was 0.53 (standard error 0.17, p<0.001). We conclude that CAA can be reliably and accurately measured in DBS collected onto the filter paper that is most commonly used for clinical care and research, and that can be stored for prolonged periods of time. This finding opens new avenues for future work among more than 700 million individuals living in areas worldwide in which schistosomes are endemic. PMID:26149541
van Boxtel, M P; ten Tusscher, M P; Metsemakers, J F; Willems, B; Jolles, J
2001-10-01
It is unknown to what extent the performance on the Stroop color-word test is affected by reduced visual function in older individuals. We tested the impact of common deficiencies in visual function (reduced distant and close acuity, reduced contrast sensitivity, and color weakness) on Stroop performance among 821 normal individuals aged 53 and older. After adjustment for age, sex, and educational level, low contrast sensitivity was associated with more time needed on card I (word naming), red/green color weakness with slower card 2 performance (color naming), and reduced distant acuity with slower performance on card 3 (interference). Half of the age-related variance in speed performance was shared with visual function. The actual impact of reduced visual function may be underestimated in this study when some of this age-related variance in Stroop performance is mediated by visual function decrements. It is suggested that reduced visual function has differential effects on Stroop performance which need to be accounted for when the Stroop test is used both in research and in clinical settings. Stroop performance measured from older individuals with unknown visual status should be interpreted with caution.
Sarangi, Laxmi Narayan; Naveena, Thodangala; Rana, Samir Kumar; Surendra, Kota Sri Naga Leela; Reddy, Rachamreddy Venkata Chandrasekhar; Bajibabu, Putla; Ponnanna, Nadikerianda Muthappa; Sharma, Girish Kumar; Srinivasan, Villuppanoor Alwar
2018-07-01
The extended frozen semen (EFS) batches produced from infectious bovine rhinotracheitis (IBR) sero-positive cattle and buffalo bulls housed in various semen stations in India are transported to the testing laboratory in liquid nitrogen (LN 2 ) for screening bovine herpesvirus-1 (BoHV-1). This procedure is laborious and poses LN 2 related hazards. An alternative logistics for transportation of samples was investigated. Use of Flinders Technology Associates (FTA ® ) elute card was evaluated for transportation of extended bovine semen to screen BoHV-1 DNA by real-time PCR targeting gB gene and the method was compared with the OIE approved Chelex resin based method. A protocol for extraction of BoHV-1 DNA from FTA ® card spotted with extended semen was optimized. The viral DNA was found to be stable on FTA ® card for at least 28 days when the cards are stored at 4°-37 °C. The analytical sensitivity for the assay was determined using variable dilutions of BoHV-1 spiked semen and positive plasmid harbouring gB gene (97bp) spotted onto FTA ® card and it was found to be 10 0.8 TCID 50 /ml or 100 copies respectively in real-time PCR. The test could detect as low as 10 0.008 TCID 50 /ml or 1 copy of positive plasmid when more number of replicates (n = 6) of the same sample were tested. This sensitivity was found to be comparable to Chelex method and both the methods demonstrated a very strong correlation (r = 0.9774; 95% CI: 0.9620-0.9860) in terms of Ct value (p < 0.0001). The diagnostic sensitivity and specificity of the FTA method in comparison to the Chelex method was 83.08% (95% CI: 71.73%-91.24%) and 93.23% (95% CI: 89.38%-96.01%) respectively when 316 samples were screened by both the methods. The degree of agreement between these two tests was good (Kappa value: 0.738; 95% CI: 0.646-0.829). The method was found to be robust and highly repeatable in inter-assay and intra-assay precision testing. The result suggests that the FTA ® card holds promise as an alternative system for transportation of EFS for downstream screening of BoHV-1 DNA. Copyright © 2018 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
McBee, Matthew T.
2016-01-01
Card and Giuliano's National Bureau of Economic Research (NBER) working paper on universal screening is discussed. This commentary provides a brief summary and critique of the article, proposes an explanation of the results in light of the author's research on the role of nominations or screening tests in the gifted identification process, and…
Nebraska State Report Card, 1999-2000 = Tarjeta informativa del Estado de Nebraska, 1999-2000.
ERIC Educational Resources Information Center
Nebraska State Dept. of Education, Lincoln.
This report, printed in English and Spanish versions, is the first Nebraska State Report Card. It provides a snapshot of Nebraska schools using statewide averages. Nebraska students scored better than students nationwide in reading, with 60% of Nebraska students in grades 3-4, 7-8, and 10-12 scoring above the median on a standardized reading test.…
Manual for Courts-Martial United States. 2002 Edition
2002-01-01
are enlistment papers, physical exam- ination papers, outline-figure and fingerprint cards, forensic laboratory reports, chain of custody docu- ments...physical examination papers, outline figure and fin- gerprint cards, forensic laboratory reports, chain of custody documents, morning reports and...Para. 142 e of the 1969 Manual, “Polygraph tests and drug- induced or hypnosis -induced interviews,” has been deleted as a result of the adoption of
Manual for Courts-Martial United States 1998 Edition.
1998-01-01
exam- ination papers, outline-figure and fingerprint cards, forensic laboratory reports, chain of custody docu- ments, morning reports and other...examination papers, outline figure and fin- gerprint cards, forensic laboratory reports, chain of custody documents, morning reports and other per...the 1969 Manual, "Polygraph tests and drug- induced or hypnosis -induced interviews," has been deleted as a result of the adoption of Rule 702. Para
Gustavsson, Inger; Lindell, Monica; Wilander, Erik; Strand, Anders; Gyllensten, Ulf
2009-10-01
The FTA elute micro card, which enable the collection, transport, and archiving of DNA could be an attractive alternative to a liquid based collection system for detection of human papillomavirus (HPV). To develop a method based on the FTA elute micro card for dry collection of cervical epithelial cell samples, suitable for subsequent PCR-based HPV testing. The method was evaluated by a comparison of the DNA collected by cytobrush and the regular FTA elute micro card from 50 cervical cell samples. The method was then used to estimate the DNA amount in 1040 samples applied to the indicating FTA elute micro card. The agreement in HPV positivity between the cytobrush and FTA samples (94%) was excellent (kappa=0.88, 95% CI 0.748-1). All the 1040 samples on the indicating FTA card had sufficient amounts of genomic DNA (>10 copies of a single copy gene) to be suitable for HPV typing. In 53 of the 1040 women the day in the menstrual cycle was noted, and the copy number during follicular phase day 9-13 was found to be statistically significantly lower than for the other three stages in the menstrual cycle (day 4-8, 14, >14) and during menopause. The indicating FTA elute micro card represents a suitable medium for collection of cervical cell samples, although follow-up studies are needed to verify the detection of low frequency HPV types.
NASA Technical Reports Server (NTRS)
Smedal, Harald A.; Havill, C. Dewey
1962-01-01
A TIME-HONORED system of recording medical histories and the data obtained on physical and laboratory examination has been that of writing the information on record sheets that go into a folder for each patient. In order to have information which would be more readily retrieved, 'a program was initiated in 1952 by the U. S. Naval School of Aviation Medicine in connection with their "Care of the Flyer" study to place this information on machine record cards. In 1958, a machine record card method was developed for recording medical data in connection with the astronaut selection program. Machine record cards were also developed by the Aero Medical Laboratory, Wright-Patterson AFB, Ohio, and the Aviation Medical Acceleration Laboratory, Naval Air Development Center, Johnsville, Pennsylvania, for use in connection with a variety of tests including acceleration stress.1 Therefore, a variety of systems resulted in which data of a medical nature could easily be recalled. During the NASA, Ames Research Center centrifuge studies/'S the pilot subjects were interviewed after each centrifuge run, or series of runs, and subjective information was recorded in a log book by the usual history taking methods referred to above. After the methods Were reviewed, it' was recognized that a card system would be very useful in recording data from our pilots after they had been exposed to acceleration stress. Since the acceleration stress cards already developed did not meet our requirements, it was decided a different card was needed.
Schunk, Mirjam; Kebede Mekonnen, Seleshi; Wondafrash, Beyene; Mengele, Carolin; Fleischmann, Erna; Herbinger, Karl-Heinz; Verweij, Jaco J.; Geldmacher, Christof; Bretzel, Gisela; Löscher, Thomas; Zeynudin, Ahmed
2015-01-01
Background In Schistosoma mansoni infection, diagnosis and control after treatment mainly rely on parasitological stool investigations which are laborious and have limited sensitivity. PCR methods have shown equal or superior sensitivity but preservation and storage methods limit their use in the field. Therefore, the use of occult blood detection cards (fecal cards) for easy sampling and storage of fecal samples for further PCR testing was evaluated in a pilot study. Methodology Stool specimens were collected in a highly endemic area for S. mansoni in Ethiopia and submitted in an investigator-blinded fashion to microscopic examination by Kato-Katz thick smear as well as to real-time PCR using either fresh frozen stool samples or stool smears on fecal cards which have been stored at ambient temperature for up to ten months. Principal Findings Out of 55 stool samples, 35 were positive by microscopy, 33 and 32 were positive by PCR of frozen samples and of fecal card samples, respectively. When microscopy was used as diagnostic “gold standard”, the sensitivity of PCR on fresh stool was 94.3% (95%-CI: 86.6; 100) and on fecal cards 91.4% (95%-CI: 82.2; 100). Conclusions The use of fecal cards proved to be a simple and useful method for stool collection and prolonged storage prior to PCR based diagnosis of S. mansoni infection. This technique may be a valuable approach for large scale surveillance and post treatment assessments PMID:26360049
Schunk, Mirjam; Kebede Mekonnen, Seleshi; Wondafrash, Beyene; Mengele, Carolin; Fleischmann, Erna; Herbinger, Karl-Heinz; Verweij, Jaco J; Geldmacher, Christof; Bretzel, Gisela; Löscher, Thomas; Zeynudin, Ahmed
2015-01-01
In Schistosoma mansoni infection, diagnosis and control after treatment mainly rely on parasitological stool investigations which are laborious and have limited sensitivity. PCR methods have shown equal or superior sensitivity but preservation and storage methods limit their use in the field. Therefore, the use of occult blood detection cards (fecal cards) for easy sampling and storage of fecal samples for further PCR testing was evaluated in a pilot study. Stool specimens were collected in a highly endemic area for S. mansoni in Ethiopia and submitted in an investigator-blinded fashion to microscopic examination by Kato-Katz thick smear as well as to real-time PCR using either fresh frozen stool samples or stool smears on fecal cards which have been stored at ambient temperature for up to ten months. Out of 55 stool samples, 35 were positive by microscopy, 33 and 32 were positive by PCR of frozen samples and of fecal card samples, respectively. When microscopy was used as diagnostic "gold standard", the sensitivity of PCR on fresh stool was 94.3% (95%-CI: 86.6; 100) and on fecal cards 91.4% (95%-CI: 82.2; 100). The use of fecal cards proved to be a simple and useful method for stool collection and prolonged storage prior to PCR based diagnosis of S. mansoni infection. This technique may be a valuable approach for large scale surveillance and post treatment assessments.
Garcia Espinosa, Arlety; Andrade Machado, René; Borges González, Susana; García González, María Eugenia; Pérez Montoto, Ariadna; Toledo Sotomayor, Guillermo
2010-01-01
The goal of the study described here was to determine if executive dysfunction and impulsivity are related to risk for suicide and suicide attempts in patients with temporal lobe epilepsy. Forty-two patients with temporal lobe epilepsy were recruited. A detailed medical history, neurological examination, serial EEGs, Mini-International Neuropsychiatric Interview, executive function, and MRI were assessed. Multiple regression analysis was carried out to examine predictive associations between clinical variables and Wisconsin Card Sorting Test measures. Patients' scores on the Risk for Suicide Scale (n=24) were greater than 7, which means they had the highest relative risk for suicide attempts. Family history of psychiatric disease, current major depressive episode, left temporal lobe epilepsy, and perseverative responses and total errors on the Wisconsin Card Sorting Test increased by 6.3 and 7.5 suicide risk and suicide attempts, respectively. Executive dysfunction (specifically perseverative responses and more total errors) contributed greatly to suicide risk. Executive performance has a major impact on suicide risk and suicide attempts in patients with temporal lobe epilepsy. 2009 Elsevier Inc. All rights reserved.
46 CFR 61.30-20 - Automatic control and safety tests.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Automatic control and safety tests. 61.30-20 Section 61... TESTS AND INSPECTIONS Tests and Inspections of Fired Thermal Fluid Heaters § 61.30-20 Automatic control and safety tests. Operational tests and checks of all safety and limit controls, combustion controls...
Lee, Chai-Jin; Kang, Dongwon; Lee, Sangseon; Lee, Sunwon; Kang, Jaewoo; Kim, Sun
2018-05-25
Determining functions of a gene requires time consuming, expensive biological experiments. Scientists can speed up this experimental process if the literature information and biological networks can be adequately provided. In this paper, we present a web-based information system that can perform in silico experiments of computationally testing hypothesis on the function of a gene. A hypothesis that is specified in English by the user is converted to genes using a literature and knowledge mining system called BEST. Condition-specific TF, miRNA and PPI (protein-protein interaction) networks are automatically generated by projecting gene and miRNA expression data to template networks. Then, an in silico experiment is to test how well the target genes are connected from the knockout gene through the condition-specific networks. The test result visualizes path from the knockout gene to the target genes in the three networks. Statistical and information-theoretic scores are provided on the resulting web page to help scientists either accept or reject the hypothesis being tested. Our web-based system was extensively tested using three data sets, such as E2f1, Lrrk2, and Dicer1 knockout data sets. We were able to re-produce gene functions reported in the original research papers. In addition, we comprehensively tested with all disease names in MalaCards as hypothesis to show the effectiveness of our system. Our in silico experiment system can be very useful in suggesting biological mechanisms which can be further tested in vivo or in vitro. http://biohealth.snu.ac.kr/software/insilico/. Copyright © 2018 Elsevier Inc. All rights reserved.
Hsu, Min-Huei; Yeh, Yu-Ting; Chen, Chien-Yuan; Liu, Chien-Hsiang; Liu, Chien-Tsai
2011-03-01
Doctor shopping (or hospital shopping), which means changing doctors (or hospitals) without professional referral for the same or similar illness conditions, is common in Hong Kong, Taiwan and Japan. Due to the lack of infrastructure for sharing health information and medication history among hospitals, doctor-shopping patients are more likely to receive duplicate medications and suffer adverse drug reactions. The Bureau of National Health Insurance (BNHI) adopted smart cards (or NHI-IC cards) as health cards in Taiwan. With their NHI-IC cards, patients can freely access different medical institutions. Because an NHI-IC card carries information about a patient's prescribed medications received from different hospitals nationwide, we used this system to address the problem of duplicate medications for outpatients visiting multiple hospitals. A computerized physician order entry (CPOE) system was enhanced with the capability of accessing NHI-IC cards and providing alerts to physicians when the system detects potential duplicate medications at the time of prescribing. Physician responses to the alerts were also collected to analyze changes in physicians' behavior. Chi-square tests and two-sided z-tests with Bonferroni adjustments for multiple comparisons were used to assess statistical significance of differences in actions taken by physicians over the three months. The enhanced CPOE system for outpatient services was implemented and installed at the Pediatric and Urology Departments of Taipei Medical University Wan-Fang Hospital in March 2007. The "Change Log" that recorded physician behavior was activated during a 3-month study period from April to June 2007. In 67.93% of patient visits, the physicians read patient NHI-IC cards, and in 16.76% of the reads, the NHI-IC card contained at least one prescribed medication that was taken by the patient. Among the prescriptions issued by physicians, on average, there were 2.36% prescriptions containing at least one medication that might be duplicative to the prior prescriptions stored in NHI-IC cards. The rate of potential duplicate medication alerts for the Pediatric Department was higher than that for the Urology Department (2.78% versus 1.67%). However, the rate of revisions to prescriptions was higher in the Urology Department than the Pediatric Department. Overall, the rate of physicians reviewing and revising their prescriptions was 29.25%; the rate of physicians reviewing without revising their prescriptions was 43.62%; the rate of physicians turning off the alert screens right after the screens popped up (overridden) was 27.13%. Thus, physicians accepted alerts to review their prescriptions with patients in most situations (72.87%). Moreover, over the study period, the rate of total revisions made to prescriptions increased and the "overridden" rate decreased. Our approach enhances the capability of CPOE systems using NHI-IC cards as a nationwide infrastructure to provide more complete patient health information and medication history sharing among hospitals in Taiwan. Thus, our system can provide a better prescribing tool to help physicians detect potential duplicate medications for frequent doctor-shopping patients and hence enhance patient safety across hospital boundaries. However, the effectiveness of detecting duplicate medications with our approach is very much dependent on the completeness of NHI-IC cards, which in turn primarily depends on physician use of the cards when prescribing. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
MALDI-TOF MS versus VITEK 2 ANC card for identification of anaerobic bacteria.
Li, Yang; Gu, Bing; Liu, Genyan; Xia, Wenying; Fan, Kun; Mei, Yaning; Huang, Peijun; Pan, Shiyang
2014-05-01
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is an accurate, rapid and inexpensive technique that has initiated a revolution in the clinical microbiology laboratory for identification of pathogens. The Vitek 2 anaerobe and Corynebacterium (ANC) identification card is a newly developed method for identification of corynebacteria and anaerobic species. The aim of this study was to evaluate the effectiveness of the ANC card and MALDI-TOF MS techniques for identification of clinical anaerobic isolates. Five reference strains and a total of 50 anaerobic bacteria clinical isolates comprising ten different genera and 14 species were identified and analyzed by the ANC card together with Vitek 2 identification system and Vitek MS together with version 2.0 database respectively. 16S rRNA gene sequencing was used as reference method for accuracy in the identification. Vitek 2 ANC card and Vitek MS provided comparable results at species level for the five reference strains. Of 50 clinical strains, the Vitek MS provided identification for 46 strains (92%) to the species level, 47 (94%) to genus level, one (2%) low discrimination, two (4%) no identification and one (2%) misidentification. The Vitek 2 ANC card provided identification for 43 strains (86%) correct to the species level, 47 (94%) correct to the genus level, three (6%) low discrimination, three (6%) no identification and one (2%) misidentification. Both Vitek MS and Vitek 2 ANC card can be used for accurate routine clinical anaerobe identification. Comparing to the Vitek 2 ANC card, Vitek MS is easier, faster and more economic for each test. The databases currently available for both systems should be updated and further developed to enhance performance.
Filter paper collection of Plasmodium falciparum mRNA for detecting low-density gametocytes
2012-01-01
Background Accurate sampling of sub-microscopic gametocytes is necessary for epidemiological studies to identify the infectious reservoir of Plasmodium falciparum. Detection of gametocyte mRNA achieves sensitive detection, but requires careful handling of samples. Filter papers can be used for collecting RNA samples, but rigorous testing of their capacity to withstand adverse storage conditions has not been fully explored. Methods Three gametocyte dilutions: 10/μL, 1.0/μL and 0.1/μL were spotted onto Whatman™ 903 Protein Saver Cards, FTA Classic Cards and 3MM filter papers that were stored under frozen, cold chain or tropical conditions for up to 13 weeks . RNA was extracted, then detected by quantitative nucleic acid sequence-based amplification (QT-NASBA) and reverse-transcriptase PCR (RT-PCR). Results Successful gametocyte detection was more frequently observed from the Whatman 903 Protein Saver Card compared to the Whatman FTA Classic Card, by both techniques (p < 0.0001). When papers were stored at higher temperatures, a loss in sensitivity was experienced for the FTA Classic Card but not the 903 Protein Saver Card or Whatman 3MM filter paper. The sensitivity of gametocyte detection was decreased when papers were stored at high humidity. Conclusions This study indicates the Whatman 903 Protein Saver Card is better for Pfs25 mRNA sampling compared to the Whatman FTA Classic Card, and that the Whatman 3MM filter paper may prove to be a satisfactory cheaper option for Pfs25 mRNA sampling. When appropriately dried, filter papers provide a useful approach to Pfs25 mRNA sampling, especially in settings where storage in RNA-protecting buffer is not possible. PMID:22873569
Filter paper collection of Plasmodium falciparum mRNA for detecting low-density gametocytes.
Jones, Sophie; Sutherland, Colin J; Hermsen, Cornelus; Arens, Theo; Teelen, Karina; Hallett, Rachel; Corran, Patrick; van der Vegte-Bolmer, Marga; Sauerwein, Robert; Drakeley, Chris J; Bousema, Teun
2012-08-08
Accurate sampling of sub-microscopic gametocytes is necessary for epidemiological studies to identify the infectious reservoir of Plasmodium falciparum. Detection of gametocyte mRNA achieves sensitive detection, but requires careful handling of samples. Filter papers can be used for collecting RNA samples, but rigorous testing of their capacity to withstand adverse storage conditions has not been fully explored. Three gametocyte dilutions: 10/μL, 1.0/μL and 0.1/μL were spotted onto Whatman™ 903 Protein Saver Cards, FTA Classic Cards and 3MM filter papers that were stored under frozen, cold chain or tropical conditions for up to 13 weeks . RNA was extracted, then detected by quantitative nucleic acid sequence-based amplification (QT-NASBA) and reverse-transcriptase PCR (RT-PCR). Successful gametocyte detection was more frequently observed from the Whatman 903 Protein Saver Card compared to the Whatman FTA Classic Card, by both techniques (p<0.0001). When papers were stored at higher temperatures, a loss in sensitivity was experienced for the FTA Classic Card but not the 903 Protein Saver Card or Whatman 3MM filter paper. The sensitivity of gametocyte detection was decreased when papers were stored at high humidity. This study indicates the Whatman 903 Protein Saver Card is better for Pfs25 mRNA sampling compared to the Whatman FTA Classic Card, and that the Whatman 3MM filter paper may prove to be a satisfactory cheaper option for Pfs25 mRNA sampling. When appropriately dried, filter papers provide a useful approach to Pfs25 mRNA sampling, especially in settings where storage in RNA-protecting buffer is not possible.
Liu, Yu-Ming; Tsai, Shang-Ying; Fleck, David E; Strakowski, Stephen M.
2011-01-01
We attempted to compare executive dysfunction with Wisconsin Card Sorting Test (WCST) among distinct national and ethnic patients with bipolar disorder in euthymia. Bipolar patients, aged 16-45 years, from United States (N=25) and Taiwan (N=30) did not differ significantly on any measure. The WCST number Failure to Maintain Set was significantly positively correlated with residual affective symptoms in Taiwanese and US patients. Selective executive dysfunction in euthymia is inherent to bipolar disorder. Euthymic bipolar patients of various ethnic groups may exhibit similar executive dysfunction. PMID:21683454
46 CFR 61.30-20 - Automatic control and safety tests.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Automatic control and safety tests. 61.30-20 Section 61.30-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND INSPECTIONS Tests and Inspections of Fired Thermal Fluid Heaters § 61.30-20 Automatic control and safety tests. Operational tests and check...
Qin, Yu; Zhang, Hongyun; Marlowe, Natalia; Fei, Mandong; Yu, Judy; Lei, Xiaoqin; Yu, Lulu; Zhang, Jia; Cao, Di; Ma, Li; Chen, Wen
2016-12-01
HIV+/AIDS women have an increased risk of developing into CIN and cervical cancer compared to the general population. Limited medical resource and the lack of AIDS relevant knowledge impair the coverage and efficiency of cervical cancer screening. To compare the clinical performance of self-collected dry storage medium (FTA Elute card) and physician-collected PreservCyt medium in detection of high risk human papillomavirus (HR HPV) among HIV-1 positive population. Three hundred HIV-1 positive women (aged 25-65) were recruited from Yunnan infectious hospital. Two cervicovaginal samples were collected from each participant: one was collected by the women themselves and applied on a FTA Elute card; the other one was collected by a physician and stored in PreservCyt solution. All the samples were tested for 14 HR HPV using Abbott RealTime High Risk HPV assay. Biopsies were taken for histological diagnosis if any abnormal impression was noticed under colposcopy. 291 (97.0%) of participants were eligible for this study. 101 (34.70%) participants were found HR HPV positive in both FTA card and PreservCyt samples, and 19 (6.53%) women were diagnosed as CIN2+. The HR HPV positive rate on samples collected by FTA Elute card and PreservCyt solution was 42.61% and 39.86%, respectively. The overall agreement was 87% (kappa=0.731) between FTA card and PreservCyt. The clinical sensitivity and specificity of FTA card and PreservCyt were 100%, 61.39% and 100%, 64.33%, respectively. In this study, FTA Elute card demonstrated a good performance on self-collected sample for HR HPV detection in HIV-1 positive population. For the women from low-resource area with HIV-1 infection, FTA Elute card could be an attractive sample collection method for cervical cancer screening. Copyright © 2016 Elsevier B.V. All rights reserved.
Dual Resolution Images from Paired Fingerprint Cards
National Institute of Standards and Technology Data Gateway
NIST Dual Resolution Images from Paired Fingerprint Cards (Web, free access) NIST Special Database 30 is being distributed for use in development and testing of fingerprint compression and fingerprint matching systems. The database allows the user to develop and evaluate data compression algorithms for fingerprint images scanned at both 19.7 ppmm (500 dpi) and 39.4 ppmm (1000 dpi). The data consist of 36 ten-print paired cards with both the rolled and plain images scanned at 19.7 and 39.4 pixels per mm. A newer version of the compression/decompression software on the CDROM can be found at the website http://www.nist.gov/itl/iad/ig/nigos.cfm as part of the NBIS package.
The automated multi-stage substructuring system for NASTRAN
NASA Technical Reports Server (NTRS)
Field, E. I.; Herting, D. N.; Herendeen, D. L.; Hoesly, R. L.
1975-01-01
The substructuring capability developed for eventual installation in Level 16 is now operational in a test version of NASTRAN. Its features are summarized. These include the user-oriented, Case Control type control language, the automated multi-stage matrix processing, the independent direct access data storage facilities, and the static and normal modes solution capabilities. A complete problem analysis sequence is presented with card-by-card description of the user input.
ERIC Educational Resources Information Center
Mukamel, Dana B.; Ladd, Heather; Weimer, David L.; Spector, William D.; Zinn, Jacqueline S.
2009-01-01
Purpose: A national quality report card for nursing homes, Nursing Home Compare, has been published since 2002. It has been shown to have some, albeit limited, positive impact on quality of care. The objective of this study was to test empirically the hypothesis that nursing homes have responded to the publication of the report by adopting cream…
[The future of clinical laboratory database management system].
Kambe, M; Imidy, D; Matsubara, A; Sugimoto, Y
1999-09-01
To assess the present status of the clinical laboratory database management system, the difference between the Clinical Laboratory Information System and Clinical Laboratory System was explained in this study. Although three kinds of database management systems (DBMS) were shown including the relational model, tree model and network model, the relational model was found to be the best DBMS for the clinical laboratory database based on our experience and developments of some clinical laboratory expert systems. As a future clinical laboratory database management system, the IC card system connected to an automatic chemical analyzer was proposed for personal health data management and a microscope/video system was proposed for dynamic data management of leukocytes or bacteria.
Comparing ImmunoCard with two EIA assays for Clostridium difficile toxins.
Chan, Edward L; Seales, Diane; Drum, Hong
2009-01-01
To compare three Clostridium difficile EIA kits for the detection of C. difficile toxins from clinical specimens. A total of 287 fresh and stored stool specimens were tested using all three assays. Stools with discrepant results were sent to a reference laboratory for tissue cytotoxin assay. Trinity Medical Center, a community hospital with network hospitals. Patients with diarrhea submitted stools for detection of C. difficile toxins. Of the 287 stool specimens, 116 were positive and 171 negative for C. difficile toxins. The sensitivity, specificity, and positive and negative predictive values of Meridian EIA assay were 99.1, 97.7, 96.6, and 99.4%; ImmunoCard were 100, 98.2, 97.5, and 100%; BioStar OIA assay were 94, 98.8, 98.2, and 96% respectively. ImmunoCardprovides the best sensitivity (100%) for C. difficile toxins A and B detection. The BioStar OIA rapid test missed seven positive stool specimens possibly due to failure to detect toxin B. ImmunoCard has slightly higher predictive values, shorter turnaround time and greater convenience compared to the Meridian EIA Assay. ImmunoCard may be cost effective not only in smaller laboratories, but also in high volume laboratories, when used on a STAT basis or single request.
[Effect of development and aging on the modified Wisconsin Card Sorting Test in normal subjects].
Kado, Yoko; Sanada, Satoshi; Yanagihara, Masafumi; Ogino, Tatsuya; Abiru, Kiyoko; Nakano, Kousuke
2004-11-01
The Wisconsin card sorting test (WCST) is applied to various types of neurological disorders. Since WCST requires the examinee's sustained efforts, it is not readily applicable to children with developmental disorders. In order to overcome this weakness, Keio version WCST (KWCST) was developed by reducing the number of cards from 128 to 48 and presenting them in two steps separated by a short pause. During which a brief instruction was given. This study was performed to clarify the changes with age in indices of KWCST and to obtain the normative value. Three hundred thirty five normal subjects, ranging from 5 to 82 years of age were examined. A simple regression analysis showed a significant age-related changes. Subjects between the middle thirties and the middle forties showed the best score in such indices as the categories achieved, perseverative errors of Nelson, difficulties of maintaining set, numbers of response cards until the first category achieved, and total errors. Most of the scores were improved in the second step across the all age groups, which might have resulted from learning during the first step and the instruction provided before the second step. KWCST can be performed briefly, and is suitable for cases with attention deficit/hyperactivity disorder and pervasive developmental disorder.
Sagheri, D; McLoughlin, J; Clarkson, J J
2009-03-01
The aim was to record dental caries levels and the presence of fissure sealants in 12-year-old schoolchildren whose domestic water supply had been fluoridated since birth in Dublin (Ireland). Cross-sectional study. Participants A representative, random sample of 12-year-old schoolchildren in north-west Dublin. Dental caries levels were recorded using WHO criteria and fissure sealant was recorded when sealant was detectable on a permanent molar tooth. Medical card ownership, as a surrogate for disadvantage, was recorded by use of a questionnaire. Three-hundred and thirty-two (332) children were examined. The mean DMFT was 0.80 (SD 1.24). Analysis (Mann-Whitney U test) based on stratification of the sample according to medical-card status revealed no statistically significant difference between DMFT median scores of children of medical-card holders (i.e., social disadvantage background) and non medical-card holders (p-value = 0.23). However, the data revealed a social gradient in the presence of at least one fissure sealant. Approximately 10% more children in the group of medical-card holders had no fissure sealants present. Fisher's exact test was used to examine the association between the absence of fissure sealants and at least one fissure sealant between the two groups and was considered to be statistically significant (p-value = 0.04). This study demonstrated a social gradient in the presence of fissure sealants, but no such gradient in dental caries levels. This demonstrates the importance of population-based measures in the prevention of dental caries, such as water fluoridation, in reducing oral health inequalities.
Weil, Gary J.; Curtis, Kurt C.; Fakoli, Lawrence; Fischer, Kerstin; Gankpala, Lincoln; Lammie, Patrick J.; Majewski, Andrew C.; Pelletreau, Sonia; Won, Kimberly Y.; Bolay, Fatorma K.; Fischer, Peter U.
2013-01-01
Global Program to Eliminate Lymphatic Filariasis (GPELF) guidelines call for using filarial antigen testing to identify endemic areas that require mass drug administration (MDA) and for post-MDA surveillance. We compared a new filarial antigen test (the Alere Filariasis Test Strip) with the reference BinaxNOW Filariasis card test that has been used by the GPELF for more than 10 years. Laboratory testing of 227 archived serum or plasma samples showed that the two tests had similar high rates of sensitivity and specificity and > 99% agreement. However, the test strip detected 26.5% more people with filarial antigenemia (124/503 versus 98/503) and had better test result stability than the card test in a field study conducted in a filariasis-endemic area in Liberia. Based on its increased sensitivity and other practical advantages, we believe that the test strip represents a major step forward that will be welcomed by the GPELF and the filariasis research community. PMID:23690552
Jankowska, Agnieszka M; Klimkiewicz, Robert; Kubsik, Anna; Klimkiewicz, Paulina; Śmigielski, Janusz; Woldańska-Okońska, Marta
2017-08-01
Executive dysfunctions are part of the clinical symptoms of a stroke and can inhibit the process of rehabilitation. Patients with impaired executive functions may manifest aggression, impulsiveness, impaired thinking and planning. The aim of this study was to assess the effect of the ischemic focus location on the effectiveness of physiotherapy in improving the executive functions in patients after stroke. Ninety patients after unilateral ischemic cerebral stroke were studied. We studied 45 patients treated at the Department of Rehabilitation and Physical Medicine of the WAM University Hospital of Lodz for 5 weeks. The rehabilitation program included: kinesitherapy, physiotherapy, speech therapy, psychological consultations and psychotherapy. The control group consisted of patients who were waiting for admission to the Department of Rehabilitation. The patients in both groups were divided into three subgroups with different locations of stroke: front, back and subcortical. Executive functions were measured by the Wisconsin Card Sorting Test (WCST), the trail making test (TMT - A, TMT - B), the verbal fluency test (VFT). Patients rehabilitated in the hospital with the front and subcortical lesion location reported improvement in executive functions in terms of a greater number of the analyzed indicators of the Wisconsin Card Sorting Test (WCST) than those with the back lesion location. Patients rehabilitated at home with the subcortical lesion location did not experience a significant improvement in executive functions in any of the analyzed indicators of the Wisconsin Card Sorting Test (WCST). Most of the indicators, with the exception of the total errors of Wisconsin Card Sorting Test (WCST) and TMT B, have not been modified by the location of stroke. Executive dysfunction occurs not only in patients with an anterior location of the stroke, but also in the posterior and subcortical locations. Patients with a subcortical location of the stroke require more treatment to mitigate the dysfunction.
Semi-automatic object geometry estimation for image personalization
NASA Astrophysics Data System (ADS)
Ding, Hengzhou; Bala, Raja; Fan, Zhigang; Eschbach, Reiner; Bouman, Charles A.; Allebach, Jan P.
2010-01-01
Digital printing brings about a host of benefits, one of which is the ability to create short runs of variable, customized content. One form of customization that is receiving much attention lately is in photofinishing applications, whereby personalized calendars, greeting cards, and photo books are created by inserting text strings into images. It is particularly interesting to estimate the underlying geometry of the surface and incorporate the text into the image content in an intelligent and natural way. Current solutions either allow fixed text insertion schemes into preprocessed images, or provide manual text insertion tools that are time consuming and aimed only at the high-end graphic designer. It would thus be desirable to provide some level of automation in the image personalization process. We propose a semi-automatic image personalization workflow which includes two scenarios: text insertion and text replacement. In both scenarios, the underlying surfaces are assumed to be planar. A 3-D pinhole camera model is used for rendering text, whose parameters are estimated by analyzing existing structures in the image. Techniques in image processing and computer vison such as the Hough transform, the bilateral filter, and connected component analysis are combined, along with necessary user inputs. In particular, the semi-automatic workflow is implemented as an image personalization tool, which is presented in our companion paper.1 Experimental results including personalized images for both scenarios are shown, which demonstrate the effectiveness of our algorithms.
Lambert, N; Plumb, J; Looise, B; Johnson, I T; Harvey, I; Wheeler, C; Robinson, M; Rolfe, P
2005-08-01
The aim of the study was to test the feasibility of using smart card technology to track the eating behaviours of nearly a thousand children in a school cafeteria. Within a large boys' school a smart card based system was developed that was capable of providing a full electronic audit of all the individual transactions that occurred within the cafeteria. This dataset was interfaced to an electronic version of the McCance and Widdowson composition of foods dataset. The accuracy of the smart card generated data and the influence of portion size and wastage were determined empirically during two 5-day trials. The smart card system created succeeded in generating precise data on the food choices made by hundreds of children over an indefinite time period. The data was expanded to include a full nutrient analysis of all the foods chosen. The accuracy of this information was only constrained by the limitations facing all food composition research, e.g. variations in recipes, portion sizes, cooking practices, etc. Although technically possible to introduce wastage correction factors into the software, thereby providing information upon foods consumed, this was not seen as universally practical. The study demonstrated the power of smart card technology for monitoring food/nutrient choice over limitless time in environments such as school cafeterias. The strengths, limitations and applications of such technology are discussed.
Use of FTA technology for detection of Trichomonas gallinae.
Holt, Jennifer C; Purple, Kathryn E; Gerhold, Richard
2015-09-15
Trichomonas gallinae is the causative agent for avian trichomonosis, which can have important population implications for domestic turkeys, columbids, raptors, and various passeriformes. Continued population surveillance and genotype distribution is needed to elucidate transmission dynamics and prevalence of T. gallinae among free-ranging birds. However, obtaining live cultures for laboratory testing is logistically challenging, limiting the ability to perform surveillance and genotype investigations. In this study, we evaluated non-indicating FTA Elute cards as a potential sampling storage substrate for downstream use in molecular identification of two T. gallinae isolates. Isolate concentrations of 10 or 100 trichomonads/40 μl were inoculated onto a FTA Elute card in triplicate. At each time point (48 h, 2 weeks, and 3 weeks), DNA elution procedures were performed on the cards, and the eluents were analyzed by conventional polymerase chain reaction (PCR) using trichomonad-specific primers. Three PCR-positive samples were detected at 48 h from one isolate; however, all eluents from cards held for 2 and 3 weeks were PCR-negative. Our results suggest that use of FTA Elute cards for nucleic acid storage can lead to low PCR sensitivity of T. gallinae in low concentrations, such as those found in non-clinical birds; however, more research is needed to fully evaluate the efficacy of FTA Elute cards as a diagnostic tool for T. gallinae. Copyright © 2015 Elsevier B.V. All rights reserved.
Differences in motives between Millennial and Generation X medical students.
Borges, Nicole J; Manuel, R Stephen; Elam, Carol L; Jones, Bonnie J
2010-06-01
OBJECTIVES Three domains comprise the field of human assessment: ability, motive and personality. Differences in personality and cognitive abilities between generations have been documented, but differences in motive between generations have not been explored. This study explored generational differences in medical students regarding motives using the Thematic Apperception Test (TAT). METHODS Four hundred and twenty six students (97% response rate) at one medical school (Generation X = 229, Millennials = 197) who matriculated in 1995 & 1996 (Generation X) or in 2003 & 2004 (Millennials) wrote a story after being shown two TAT picture cards. Student stories for each TAT card were scored for different aspects of motives: Achievement, Affiliation, and Power. RESULTS A multiple analysis of variance (p < 0.05) showed significant differences between Millennials' and Generation X-ers' needs for Power on both TAT cards and needs for Achievement and Affiliation on one TAT card. The main effect for gender was significant for both TAT cards regarding Achievement. No main effect for ethnicity was noted. CONCLUSIONS Differences in needs for Achievement, Affiliation and Power exist between Millennial and Generation X medical students. Generation X-ers scored higher on the motive of Power, whereas Millennials scored higher on the motives of Achievement and Affiliation.
Molteni, C G; Terranova, L; Zampiero, A; Galeone, C; Principi, N; Esposito, S
2013-01-01
Isolating genomic DNA from blood samples is essential when studying the associations between genetic variants and susceptibility to a given clinical condition, or its severity. This study of three extraction techniques and two types of commercially available cards involved 219 children attending our outpatient pediatric clinic for follow-up laboratory tests after they had been hospitalised. An aliquot of venous blood was drawn into plastic tubes without additives and, after several inversions, 80 microL were put on circles of common paper cards and Whatman FTA-treated cards. Three extraction methods were compared: the Qiagen Investigator, Gensolve, and Masterpure. The best method in terms of final DNA yield was Masterpure, which led to a significantly higher yield regardless of the type of card (p less than 0.001), followed by Qiagen Investigator and Gensolve. Masterpure was also the best in terms of price, seemed to be simple and reliable, and required less hands-on time than other techniques. These conclusions support the use of Masterpure in studies that evaluate the associations between genetic variants and the severity or prevalence of infectious diseases.
Flanagan, Emma C; Lagarde, Julien; Hahn, Valérie; Guichart-Gomez, Elodie; Sarazin, Marie; Hornberger, Michael; Bertoux, Maxime
2018-05-01
Environmental dependency syndrome (EDS), including utilization (UB) and imitation (IB) behaviors, is often reported in behavioral variant frontotemporal dementia (bvFTD). These behaviors are commonly attributed to executive dysfunction. However, inconsistent associations between EDS and poor executive performance has led to an alternative "social hypothesis," instead implicating patients' misinterpretation of the examiner's intention. We investigated the possible explanatory cognitive mechanisms of EDS in bvFTD by relating UB and IB to performance on tests of executive functioning and theory of mind (ToM). This study analyzed retrospective data of 32 bvFTD patients. Data included scores of UB and IB, various executive measures, and ToM assessment using the faux pas test, from which we extracted a mental attribution score. Of the patients, 15.6% and 40.6% exhibited UB and IB, respectively. We conducted an automatic linear modeling analysis with executive and mental attribution measures as predictor variables, and UB and IB sequentially considered as target variables. ToM mental attribution score, visual abstraction and flexibility measures from the Wisconsin Card Sorting Test, and motor sequence performance significantly (corrected ps < .05) predicted IB. No executive or ToM measures significantly predicted UB. These findings reveal a complex interaction between executive dysfunction and mental attribution deficits influencing the prevalence of EDS in bvFTD. Further investigation is required to improve our understanding of the mechanisms underlying these behaviors. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Hanauer, David A.; Wentzell, Katherine; Laffel, Nikki
2009-01-01
Abstract Background: Cell phone text messaging, via the Short Messaging Service (SMS), offers the promise of a highly portable, well-accepted, and inexpensive modality for engaging youth and young adults in the management of their diabetes. This pilot and feasibility study compared two-way SMS cell phone messaging with e-mail reminders that were directed at encouraging blood glucose (BG) monitoring. Methods: Forty insulin-treated adolescents and young adults with diabetes were randomized to receive electronic reminders to check their BG levels via cell phone text messaging or e-mail reminders for a 3-month pilot study. Electronic messages were automatically generated, and participant replies with BG results were processed by the locally developed Computerized Automated Reminder Diabetes System (CARDS). Participants set their schedule for reminders on the secure CARDS website where they could also enter and review BG data. Results: Of the 40 participants, 22 were randomized to receive cell phone text message reminders and 18 to receive e-mail reminders; 18 in the cell phone group and 11 in the e-mail group used the system. Compared to the e-mail group, users in the cell phone group received more reminders (180.4 vs. 106.6 per user) and responded with BG results significantly more often (30.0 vs. 6.9 per user, P=0.04). During the first month cell phone users submitted twice as many BGs as e-mail users (27.2 vs. 13.8 per user); by month 3, usage waned. Conclusions: Cell phone text messaging to promote BG monitoring is a viable and acceptable option in adolescents and young adults with diabetes. However, maintaining interest levels for prolonged intervals remains a challenge. PMID:19848576
Hanauer, David A; Wentzell, Katherine; Laffel, Nikki; Laffel, Lori M
2009-02-01
Cell phone text messaging, via the Short Messaging Service (SMS), offers the promise of a highly portable, well-accepted, and inexpensive modality for engaging youth and young adults in the management of their diabetes. This pilot and feasibility study compared two-way SMS cell phone messaging with e-mail reminders that were directed at encouraging blood glucose (BG) monitoring. Forty insulin-treated adolescents and young adults with diabetes were randomized to receive electronic reminders to check their BG levels via cell phone text messaging or e-mail reminders for a 3-month pilot study. Electronic messages were automatically generated, and participant replies with BG results were processed by the locally developed Computerized Automated Reminder Diabetes System (CARDS). Participants set their schedule for reminders on the secure CARDS website where they could also enter and review BG data. Of the 40 participants, 22 were randomized to receive cell phone text message reminders and 18 to receive e-mail reminders; 18 in the cell phone group and 11 in the e-mail group used the system. Compared to the e-mail group, users in the cell phone group received more reminders (180.4 vs. 106.6 per user) and responded with BG results significantly more often (30.0 vs. 6.9 per user, P = 0.04). During the first month cell phone users submitted twice as many BGs as e-mail users (27.2 vs. 13.8 per user); by month 3, usage waned. Cell phone text messaging to promote BG monitoring is a viable and acceptable option in adolescents and young adults with diabetes. However, maintaining interest levels for prolonged intervals remains a challenge.
NASA Technical Reports Server (NTRS)
Baruah, P. K.; Bussoletti, J. E.; Chiang, D. T.; Massena, W. A.; Nelson, F. D.; Furdon, D. J.; Tsurusaki, K.
1981-01-01
The Maintenance Document is a guide to the PAN AIR software system, a system which computes the subsonic or supersonic linear potential flow about a body of nearly arbitrary shape, using a higher order panel method. The document describes the over-all system and each program module of the system. Sufficient detail is given for program maintenance, updating and modification. It is assumed that the reader is familiar with programming and CDC (Control Data Corporation) computer systems. The PAN AIR system was written in FORTRAN 4 language except for a few COMPASS language subroutines which exist in the PAN AIR library. Structured programming techniques were used to provide code documentation and maintainability. The operating systems accommodated are NOS 1.2, NOS/BE and SCOPE 2.1.3 on the CDC 6600, 7600 and Cyber 175 computing systems. The system is comprised of a data management system, a program library, an execution control module and nine separate FORTRAN technical modules. Each module calculates part of the posed PAN AIR problem. The data base manager is used to communicate between modules and within modules. The technical modules must be run in a prescribed fashion for each PAN AIR problem. In order to ease the problem of supplying the many JCL cards required to execute the modules, a separate module called MEC (Module Execution Control) was created to automatically supply most of the JCL cards. In addition to the MEC generated JCL, there is an additional set of user supplied JCL cards to initiate the JCL sequence stored on the system.
Human Factors Assessment and Redesign of the ISS Respiratory Support Pack (RSP) Cue Card
NASA Technical Reports Server (NTRS)
Byrne, Vicky; Hudy, Cynthia; Whitmore, Mihriban; Smith, Danielle
2007-01-01
The Respiratory Support Pack (RSP) is a medical pack onboard the International Space Station (ISS) that contains much of the necessary equipment for providing aid to a conscious or unconscious crewmember in respiratory distress. Inside the RSP lid pocket is a 5.5 by 11 inch paper procedural cue card, which is used by a Crew Medical Officer (CMO) to set up the equipment and deliver oxygen to a crewmember. In training, crewmembers expressed concerns about the readability and usability of the cue card; consequently, updating the cue card was prioritized as an activity to be completed. The Usability Testing and Analysis Facility at the Johnson Space Center (JSC) evaluated the original layout of the cue card, and proposed several new cue card designs based on human factors principles. The approach taken for the assessment was an iterative process. First, in order to completely understand the issues with the RSP cue card, crewmember post training comments regarding the RSP cue card were taken into consideration. Over the course of the iterative process, the procedural information was reorganized into a linear flow after the removal of irrelevant (non-emergency) content. Pictures, color coding, and borders were added to highlight key components in the RSP to aid in quickly identifying those components. There were minimal changes to the actual text content. Three studies were conducted using non-medically trained JSC personnel (total of 34 participants). Non-medically trained personnel participated in order to approximate a scenario of limited CMO exposure to the RSP equipment and training (which can occur six months prior to the mission). In each study, participants were asked to perform two respiratory distress scenarios using one of the cue card designs to simulate resuscitation (using a mannequin along with the hardware). Procedure completion time, errors, and subjective ratings were recorded. The last iteration of the cue card featured a schematic of the RSP, colors, borders, and simplification of the flow of information. The time to complete the RSP procedure was reduced by approximately three minutes with the new design. In an emergency situation, three minutes significantly increases the probability of saving a life. In addition, participants showed the highest preference for this design. The results of the studies and the new design were presented to a focus group of astronauts, flight surgeons, medical trainers, and procedures personnel. The final cue card was presented to a medical control board and approved for flight. The revised RSP cue card is currently onboard ISS.
Development and Analysis of Closed Cycle Circulator Elements.
1980-05-01
circuits are mounted on cards accessible through a hinged rear panel for service or adjustments. Cards may be removed in groups of 3 for servicing without...voltage signal is processed in such a way that it became linearly related to velocity of the gas flow. The use of these modules ensures the frequency...most important idiagnostic to be measured optically. This test is broken down into two categories: a medium homogeneity category *1 in which
Fecal immunochemical test (FIT)
... the toilet water. Touch the brush on the space indicated on the test card. Add the brush ... DA, Levin TR; United States Multi-Society Task Force on Colorectal Cancer. Guidelines for colonoscopy surveillance after ...
Lenticular card: a new method for denture identification.
Colvenkar, Shreya S
2010-01-01
The need for denture marking is important for forensic and social reasons in case patients need to be identified individually. Majority of the surface marking and inclusion techniques are expensive, time consuming, and do not permit the incorporation of large amounts of information. In this article, the method to include a lenticular identification card stood out from the currently available denture marking methods in various ways. The lenticular card stores the patient's information has two or more images that can be viewed by changing the angle of view. The maxillary denture was processed according to the manufacturer's instructions. The lenticular identification card was incorporated in the external posterior buccal surface of the maxillary denture using salt and pepper technique. For testing of durability, denture with the identifier was placed in water for up to 4 months. The proposed method is simple, cheap, and can store a large amount of information, thus allowing quick identification of the denture wearer. The labels showed no sign of fading or deterioration.
Ndzi, Edward S.; Asonganyi, Tazoacha; Nkinin, Mary Bello; Xiao, Lihua; Didier, Elizabeth S.; Bowers, Lisa C.; Nkinin, Stephenson W.; Kaneshiro, Edna S.
2015-01-01
Several enteric microsporidia species have been detected in humans and other vertebrates and their identifications at the genotype level are currently being elucidated. As advanced methods, reagents, and disposal kits for detecting and identifying pathogens become commercially available, it is important to test them in settings other than in laboratories with “state-of-the-art” equipment and well-trained staff members. In the present study, we sought to detect microsporidia DNA preserved and extracted from FTA (fast technology analysis) cards spotted with human fecal suspensions obtained from Cameroonian volunteers living in the capital city of Yaoundé to preclude the need for employing spore-concentrating protocols. Further, we tested whether amplicon nucleotide sequencing approaches could be used on small aliquots taken from the cards to elucidate the diversity of microsporidia species and strains infecting native residents. Of 196 samples analyzed, 12 (6.1%) were positive for microsporidia DNA; Enterocytozoon bieneusi (Type IV and KIN-1), Encephalitozoon cuniculi, and Encephalitozoon intestinalis were identified. These data demonstrate the utility of the FTA cards in identifying genotypes of microsporidia DNA in human fecal samples that may be applied to field testing for prevalence studies. PMID:26303263
Messina, Bruna; Fuentes, Daniel; Tavares, Hermano; Abdo, Carmita H N; Scanavino, Marco de T
2017-03-01
Despite the serious behavioral consequences faced by individuals with sexual compulsivity, related neuropsychological studies are sparse. To compare decision making and cognitive flexibility at baseline and after exposure to an erotic video in sexually compulsive participants and non-sexually compulsive controls. The sample consisted of 30 sexually compulsive men and 30 controls. Cognitive flexibility was investigated through the Wisconsin Card Sorting Test and decision making was examined through the Iowa Gambling Task. Wisconsin Card Sorting Test categories, correct responses, and perseverative errors and Iowa Gambling Task general trends and blocks. Sexually compulsive subjects and controls performed similarly at baseline. After watching an erotic video, controls performed better in block 1 of the Iowa Gambling Task (P = .01) and had more correct responses on the Wisconsin Card Sorting Test (P = .01). The controls presented fewer impulsive initial choices and better cognitive flexibility after exposure to erotic stimuli. Messina B, Fuentes D, Tavares H, et al. Executive Functioning of Sexually Compulsive and Non-Sexually Compulsive Men Before and After Watching an Erotic Video. J Sex Med 2017;14:347-354. Copyright © 2017. Published by Elsevier Inc.
A Timing Synchronizer System for Beam Test Setups Requiring Galvanic Isolation
NASA Astrophysics Data System (ADS)
Meder, Lukas Dominik; Emschermann, David; Frühauf, Jochen; Müller, Walter F. J.; Becker, Jürgen
2017-07-01
In beam test setups detector elements together with a readout composed of frontend electronics (FEE) and usually a layer of field-programmable gate arrays (FPGAs) are being analyzed. The FEE is in this scenario often directly connected to both the detector and the FPGA layer what in many cases requires sharing the ground potentials of these layers. This setup can become problematic if parts of the detector need to be operated at different high-voltage potentials, since all of the FPGA boards need to receive a common clock and timing reference for getting the readout synchronized. Thus, for the context of the compressed baryonic matter experiment a versatile timing synchronizer (TS) system was designed providing galvanically isolated timing distribution links over twisted-pair cables. As an electrical interface the so-called timing data processing board FPGA mezzanine card was created for being mounted onto FPGA-based advanced mezzanine cards for mTCA.4 crates. The FPGA logic of the TS system connects to this card and can be monitored and controlled through IPBus slow-control links. Evaluations show that the system is capable of stably synchronizing the FPGA boards of a beam test setup being integrated into a hierarchical TS network.
NASA Astrophysics Data System (ADS)
Maffucci, Irene; Hu, Xiao; Fumagalli, Valentina; Contini, Alessandro
2018-03-01
Nwat-MMGBSA is a variant of MM-PB/GBSA based on the inclusion of a number of explicit water molecules that are the closest to the ligand in each frame of a molecular dynamics trajectory. This method demonstrated improved correlations between calculated and experimental binding energies in both protein-protein interactions and ligand-receptor complexes, in comparison to the standard MM-GBSA. A protocol optimization, aimed to maximize efficacy and efficiency, is discussed here considering penicillopepsin, HIV1-protease, and BCL-XL as test cases. Calculations were performed in triplicates on both classic HPC environments and on standard workstations equipped by a GPU card, evidencing no statistical differences in the results. No relevant differences in correlation to experiments were also observed when performing Nwat-MMGBSA calculations on 4 ns or 1 ns long trajectories. A fully automatic workflow for structure-based virtual screening, performing from library set-up to docking and Nwat-MMGBSA rescoring, has then been developed. The protocol has been tested against no rescoring or standard MM-GBSA rescoring within a retrospective virtual screening of inhibitors of AmpC β-lactamase and of the Rac1-Tiam1 protein-protein interaction. In both cases, Nwat-MMGBSA rescoring provided a statistically significant increase in the ROC AUCs of between 20% and 30%, compared to docking scoring or to standard MM-GBSA rescoring.
Seth, Mayank; Jackson, Karen V.; Winzelberg, Sarah; Giger, Urs
2012-01-01
Objective To compare accuracy and ease of use of a card agglutination assay, an immunochromatographic cartridge method, and a gel-based method for canine blood typing. Sample Blood samples from 52 healthy blood donor dogs, 10 dogs with immune-mediated hemolytic anemia (IMHA), and 29 dogs with other diseases. Procedures Blood samples were tested in accordance with manufacturer guidelines. Samples with low PCVs were created by the addition of autologous plasma to separately assess the effects of anemia on test results. Results Compared with a composite reference standard of agreement between 2 methods, the gel-based method was found to be 100% accurate. The card agglutination assay was 89% to 91% accurate, depending on test interpretation, and the immunochromatographic cartridge method was 93% accurate but 100% specific. Errors were observed more frequently in samples from diseased dogs, particularly those with IMHA. In the presence of persistent autoagglutination, dog erythrocyte antigen (DEA) 1.1 typing was not possible, except with the immunochromatographic cartridge method. Conclusions and Clinical Relevance The card agglutination assay and immunochromatographic cartridge method, performed by trained personnel, were suitable for in-clinic emergency DEA 1.1 blood typing. There may be errors, particularly for samples from dogs with IMHA, and the immunochromatographic cartridge method may have an advantage of allowing typing of samples with persistent autoagglutination. The laboratory gel-based method would be preferred for routine DEA 1.1 typing of donors and patients if it is available and time permits. Current DEA 1.1 typing techniques appear to be appropriately standardized and easy to use. PMID:22280380
The development of resident "report cards" in the context of managed care education.
Farquhar, L; Keefe, C; Priester, F; Colenda, C; Wadland, W
2001-11-01
This article describes the development of residents' report cards as one component of a curriculum on physician profiling for primary care residents. Thirty-two first-year residents matriculating into family practice, internal medicine, pediatrics, and obstetrics-gynecology residency programs in 1998 were profiled. The patient information in the report cards was limited to data on a panel of Medicaid patients initially seen in the resident ambulatory care clinics. All subsequent patient care for that population was also included. The method was multi-step and complex, involving hospital billing personnel and cooperation with a managed care partner. A three-session educational program was developed to introduce the concept of physician profiling. The first session consisted of a panel discussion on managed care. The second session was devoted to a discussion of hypothetical physician profiles with inappropriate length of stays, days/1,000, low numbers of office visits combined with high urgent-care use, and high outpatient services utilization. Small groups of residents participated in a problem-identification process as if they were members of a group practice. Residents identified problems in the reports and made suggestions for behavioral changes. A final session presented residents with their own personal report cards. Residents were surveyed both at the beginning of their first year and before and after the educational intervention on profiling. Resident attitudes, which were negative toward managed care at the outset, became generally more positive. Comparisons of pre-test and post-test means on the five-point Likert scale, using a paired-samples t-test, revealed significant changes in the residents' attitudes overall.
Wanji, Samuel; Amvongo-Adjia, Nathalie; Njouendou, Abdel Jelil; Kengne-Ouafo, Jonas Arnaud; Ndongmo, Winston Patrick Chounna; Fombad, Fanny Fri; Koudou, Benjamin; Enyong, Peter A; Bockarie, Moses
2016-05-05
The immunochromatographic test (ICT) for lymphatic filariasis is a serological test designed for unequivocal detection of circulating Wuchereria bancrofti antigen. It was validated and promoted by WHO as the primary diagnostic tool for mapping and impact monitoring for disease elimination following interventions. The initial tests for specificity and sensitivity were based on samples collected in areas free of loiasis and the results suggested a near 100% specificity for W. bancrofti. The possibility of cross-reactivity with non-Wuchereria bancrofti antigens was not investigated until recently, when false positive results were observed in three independent studies carried out in Central Africa. Associations were demonstrated between ICT positivity and Loa loa microfilaraemia, but it was not clearly established if these false positive results were due to L. loa or can be extended to other filarial nematodes. This study brought further evidences of the cross-reactivity of ICT card with L. loa and Onchocerca ochengi (related to O. volvulus parasite) using in vivo and in vitro systems. Two filarial/host experimental systems (L. loa-baboon and O. ochengi-cattle) and the in vitro maintenance of different stages (microfilariae, infective larvae and adult worm) of the two filariae were used in three experiments per filarial species. First, whole blood and sera samples were prepared from venous blood of patent baboons and cattle, and applied on ICT cards to detect circulating filarial antigens. Secondly, larval stages of L. loa and O. ochengi as well as O. ochengi adult males were maintained in vitro. Culture supernatants were collected and applied on ICT cards after 6, 12 and 24 h of in vitro maintenance. Finally, total worm extracts (TWE) were prepared using L. loa microfilariae (Mf) and O. ochengi microfilariae, infective larvae and adult male worms. TWE were also tested on ICT cards. For each experiment, control assays (whole blood and sera from uninfected babon/cattle, culture medium and extraction buffer) were performed. Positive ICT results were obtained with whole blood and sera of L. loa microfilaremic baboons, culture supernatants of L. loa Mf and infective larvae as well as with L. loa Mf protein extracts. In contrast, negative ICT results were observed with whole blood and sera from the O. ochengi-cattle system. Surprisingly, culture supernatant of O. ochengi adult males and total worm extracts (Mf, infective larvae and adult worm) were positive to the test. This study has provided further evidence of L. loa cross-reactivity for the ICT card. All stages of L. loa seem capable of inducing the cross-reactivity. Onchocerca ochengi. can also induce cross-reactivity in vitro, but this is less likely in vivo due to the location of parasite. The availability of the parasite proteins in the blood stream determines the magnitude of the cross-reactivity. The cross-reactivity of the ICT card to these non-W. bancrofti filariae poses some doubts to the reliability and validity of the current map of LF of Central Africa that was generated using this diagnostic tool.
NASA Astrophysics Data System (ADS)
Mueanploy, Wannapa
2015-06-01
The objective of this research was to offer the way to improve engineering students in Physics topic of vector product. The sampling of this research was the engineering students at Pathumwan Institute of Technology during the first semester of academic year 2013. 1) Select 120 students by random sampling are asked to fill in a satisfaction questionnaire scale, to select size of three dimensions vector card in order to apply in the classroom. 2) Select 60 students by random sampling to do achievement test and take the test to be used in the classroom. The methods used in analysis of achievement test by the Kuder-Richardson Method (KR- 20). The results show that 12 items of achievement test are appropriate to be applied in the classroom. The achievement test gets Difficulty (P) = 0.40-0.67, Discrimination = 0.33-0.73 and Reliability (r) = 0.70.The experimental in the classroom. 3) Select 60 students by random sampling divide into two groups; group one (the controlled group) with 30 students was chosen to study in the vector product lesson by the regular teaching method. Group two (the experimental group) with 30 students was chosen to learn the vector product lesson with three dimensions vector card. 4) Analyzed data between the controlled group and the experimental group, the result showed that experimental group got higher achievement test than the controlled group significant at .01 level.
McKinney, Cushla; Stamp, Lisa K; Dalbeth, Nicola; Topless, Ruth K; Day, Richard O; Kannangara, Diluk Rw; Williams, Kenneth M; Janssen, Matthijs; Jansen, Timothy L; Joosten, Leo A; Radstake, Timothy R; Riches, Philip L; Tausche, Anne-Kathrin; Lioté, Frederic; So, Alexander; Merriman, Tony R
2015-10-13
The acute gout flare results from a localised self-limiting innate immune response to monosodium urate (MSU) crystals deposited in joints in hyperuricaemic individuals. Activation of the caspase recruitment domain-containing protein 8 (CARD8) NOD-like receptor pyrin-containing 3 (NLRP3) inflammasome by MSU crystals and production of mature interleukin-1β (IL-1β) is central to acute gouty arthritis. However very little is known about genetic control of the innate immune response involved in acute gouty arthritis. Therefore our aim was to test functional single nucleotide polymorphism (SNP) variants in the toll-like receptor (TLR)-inflammasome-IL-1β axis for association with gout. 1,494 gout cases of European and 863 gout cases of New Zealand (NZ) Polynesian (Māori and Pacific Island) ancestry were included. Gout was diagnosed by the 1977 ARA gout classification criteria. There were 1,030 Polynesian controls and 10,942 European controls including from the publicly-available Atherosclerosis Risk in Communities (ARIC) and Framingham Heart (FHS) studies. The ten SNPs were either genotyped by Sequenom MassArray or by Affymetrix SNP array or imputed in the ARIC and FHS datasets. Allelic association was done by logistic regression adjusting by age and sex with European and Polynesian data combined by meta-analysis. Sample sets were pooled for multiplicative interaction analysis, which was also adjusted by sample set. Eleven SNPs were tested in the TLR2, CD14, IL1B, CARD8, NLRP3, MYD88, P2RX7, DAPK1 and TNXIP genes. Nominally significant (P < 0.05) associations with gout were detected at CARD8 rs2043211 (OR = 1.12, P = 0.007), IL1B rs1143623 (OR = 1.10, P = 0.020) and CD14 rs2569190 (OR = 1.08; P = 0.036). There was significant multiplicative interaction between CARD8 and IL1B (P = 0.005), with the IL1B risk genotype amplifying the risk effect of CARD8. There is evidence for association of gout with functional variants in CARD8, IL1B and CD14. The gout-associated allele of IL1B increases expression of IL-1β - the multiplicative interaction with CARD8 would be consistent with a synergy of greater inflammasome activity (resulting from reduced CARD8) combined with higher levels of pre-IL-1β expression leading to increased production of mature IL-1β in gout.
CARD8 rs2043211 polymorphism is associated with gout in a Chinese male population.
Chen, Ying; Ren, Xianfeng; Li, Changgui; Xing, Shichao; Fu, Zhengju; Yuan, Ying; Wang, Robin; Wang, Yangang; Lv, Wenshan
2015-01-01
BACKGROUND &AIM: Previous studies have suggested genetic factors are involved in the development of gout. We performed a case-control study to investigate the genetic association between CARD8 rs2043211 polymorphism and gout. A total of 396 male patients with gout and 403 age- and sex- matched healthy controls were included in this study. Genotyping was performed using TaqMan SNP Genotyping Assays. An association analysis was carried out using the χ² test. The genotype-phenotype analysis was also conducted. The genotype distribution of CARD8 rs2043211 polymorphism confirmed to HWE in the controls (P = 0.27). There was an obvious difference in the genotype distribution of CARD8 rs2043211 polymorphism between cases and controls (P = 0.017). In addition, there was an obvious association between CARD8 rs2043211 polymorphism and gout under the recessive comparison model (AA vs. OR = 0.65, 95%CI 0.47-0.88, P = 0.006). Patients carrying genotype TT of CARD8 rs2043211 polymorphism had higher triglycerides levels compared to those carrying the AA genotype (2.77±2.08 mmol/L vs. 2.07±1.15 mmol/L, P = 0.01). Patients with the TT genotype also had significantly higher systolic blood pressure compared with those with the AA genotype (142.11±21.10 mmHg vs. 135.38±14.66 mmHg, P = 0.03). Patients carrying TT genotype also had an increased risk of renal calculus compared with those carrying the AA genotype. CARD8 rs2043211 polymorphism is significantly associated with susceptibility to gout in Chinese Han males. © 2015 S. Karger AG, Basel.
Guerra, Ernesto; Knoeferle, Pia
2018-01-01
Existing evidence has shown a processing advantage (or facilitation) when representations derived from a non-linguistic context (spatial proximity depicted by gambling cards moving together) match the semantic content of an ensuing sentence. A match, inspired by conceptual metaphors such as 'similarity is closeness' would, for instance, involve cards moving closer together and the sentence relates similarity between abstract concepts such as war and battle. However, other studies have reported a disadvantage (or interference) for congruence between the semantic content of a sentence and representations of spatial distance derived from this sort of non-linguistic context. In the present article, we investigate the cognitive mechanisms underlying the interaction between the representations of spatial distance and sentence processing. In two eye-tracking experiments, we tested the predictions of a mechanism that considers the competition, activation, and decay of visually and linguistically derived representations as key aspects in determining the qualitative pattern and time course of that interaction. Critical trials presented two playing cards, each showing a written abstract noun; the cards turned around, obscuring the nouns, and moved either farther apart or closer together. Participants then read a sentence expressing either semantic similarity or difference between these two nouns. When instructed to attend to the nouns on the cards (Experiment 1), participants' total reading times revealed interference between spatial distance (e.g., closeness) and semantic relations (similarity) as soon as the sentence explicitly conveyed similarity. But when instructed to attend to the cards (Experiment 2), cards approaching (vs. moving apart) elicited first interference (when similarity was implicit) and then facilitation (when similarity was made explicit) during sentence reading. We discuss these findings in the context of a competition mechanism of interference and facilitation effects.
van Belle, Elise; Zwakhalen, Sandra M G; Caris, Josien; Van Hecke, Ann; Huisman-de Waal, Getty; Heinen, Maud
2018-02-01
To describe the tailoring of the Tell-us Card intervention for enhanced patient participation to the Dutch hospital setting using Intervention Mapping as a systematic approach. Even though patient participation is essential in any patient-to-nurse encounter, care plans often fail to take patients' preferences into account. The Tell-us Card intervention seems promising, but needs to be tailored and tested before implementation in a different setting or on large scale. Description of the Intervention Mapping framework to systematically tailor the Tell-us Card intervention to the Dutch hospital setting. Intervention Mapping consists of: (i) identification of the problem through needs assessment and determination of fit, based on patients and nurses interviews and focus group interviews; (ii) developing a logic model of change and matrices, based on literature and interviews; (iii) selection of theory-based methods and practical applications; (iv) producing programme components and piloting; (v) planning for adoption, implementation and sustainability; and (vi) preparing for programme evaluation. Knowledge, attitude, outcome expectations, self-efficacy and skills were identified as the main determinants influencing the use of the Tell-us Card. Linking identified determinants and performance objectives with behaviour change techniques from the literature resulted in a well-defined and tailored intervention and evaluation plan. The Tell-us Card intervention was adapted to fit the Dutch hospital setting and prepared for evaluation. The Medical Research Council framework was followed, and the Intervention Mapping approach was used to prepare a pilot study to confirm feasibility and relevant outcomes. This article shows how Intervention Mapping is applied within the Medical Research Council framework to adapt the Tell-us Card intervention, which could serve as a guide for the tailoring of similar interventions. © 2017 John Wiley & Sons Ltd.
26 CFR 301.6311-2 - Payment by credit card and debit card.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 26 Internal Revenue 18 2012-04-01 2012-04-01 false Payment by credit card and debit card. 301.6311....6311-2 Payment by credit card and debit card. (a) Authority to receive—(1) Payments by credit card and debit card. Internal revenue taxes may be paid by credit card or debit card as authorized by this...
26 CFR 301.6311-2 - Payment by credit card and debit card.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 26 Internal Revenue 18 2011-04-01 2011-04-01 false Payment by credit card and debit card. 301.6311....6311-2 Payment by credit card and debit card. (a) Authority to receive—(1) Payments by credit card and debit card. Internal revenue taxes may be paid by credit card or debit card as authorized by this...
26 CFR 301.6311-2 - Payment by credit card and debit card.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 26 Internal Revenue 18 2013-04-01 2013-04-01 false Payment by credit card and debit card. 301.6311....6311-2 Payment by credit card and debit card. (a) Authority to receive—(1) Payments by credit card and debit card. Internal revenue taxes may be paid by credit card or debit card as authorized by this...
26 CFR 301.6311-2 - Payment by credit card and debit card.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 26 Internal Revenue 18 2014-04-01 2014-04-01 false Payment by credit card and debit card. 301.6311....6311-2 Payment by credit card and debit card. (a) Authority to receive—(1) Payments by credit card and debit card. Internal revenue taxes may be paid by credit card or debit card as authorized by this...
ERIC Educational Resources Information Center
Meissner, Judith A.; And Others
The ETS Matched Pictures test was used in the longitudinal study to measure children's comprehension of certain grammatical features, such as past and future tenses, negation and prepositions. The task materials for both I and II consist of a set of cards, with each card having a pair of black and white pictures. Both pictures in a pair contain…
1977-09-01
the needed knowledge and skills must be provided. Ideally, these programs should be self- contained , capable of easy administration within...type of vehicle, duplicate cards were prepared. In effect, a task file was prepared, the file containing cards which described the task and...test situation contains a description of the situation. (If the operator does not actually encounter the situation, the situation is read to him by
NEW EPICS/RTEMS IOC BASED ON ALTERA SOC AT JEFFERSON LAB
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yan, Jianxun; Seaton, Chad; Allison, Trent L.
A new EPICS/RTEMS IOC based on the Altera System-on-Chip (SoC) FPGA is being designed at Jefferson Lab. The Altera SoC FPGA integrates a dual ARM Cortex-A9 Hard Processor System (HPS) consisting of processor, peripherals and memory interfaces tied seamlessly with the FPGA fabric using a high-bandwidth interconnect backbone. The embedded Altera SoC IOC has features of remote network boot via U-Boot from SD card or QSPI Flash, 1Gig Ethernet, 1GB DDR3 SDRAM on HPS, UART serial ports, and ISA bus interface. RTEMS for the ARM processor BSP were built with CEXP shell, which will dynamically load the EPICS applications atmore » runtime. U-Boot is the primary bootloader to remotely load the kernel image into local memory from a DHCP/TFTP server over Ethernet, and automatically run RTEMS and EPICS. The first design of the SoC IOC will be compatible with Jefferson Lab’s current PC104 IOCs, which have been running in CEBAF 10 years. The next design would be mounting in a chassis and connected to a daughter card via standard HSMC connectors. This standard SoC IOC will become the next generation of low-level IOC for the accelerator controls at Jefferson Lab.« less
Johnson, Mark B; Clapp, John D
2011-01-01
Given that most effective alcohol harm-reduction laws specify the blood alcohol concentration (BAC) that constitutes illegal behavior (e.g., the .08% breath alcohol concentration legal limit), interventions that allow drinkers to accurately estimate their BACs, and thus better assess their risk, have potential importance to long-term driving-under-the-influence prevention efforts. This study describes a field experiment designed to test the impact on drinking of providing "Know Your Limit" (KYL) BAC estimation cards to individuals in a natural drinking environment. We randomly sampled 1,215 U.S. residents as they entered Mexico for a night of drinking, interviewed them, and randomly assigned them to one of six experimental conditions. Participants were reinterviewed and breath-tested when they returned to the United States. The experimental conditions included providing generic warnings about drinking and driving, giving out gender-specific BAC calculator cards (KYL cards), and providing incentives to moderate their drinking. Cueing participants about the risks of drunk driving resulted in significantly lower BACs (relative to control) for participants who indicated that they would drive home. Providing KYL matrixes did not reduce BACs, and, in fact, some evidence suggests that KYL cards undermined the effect of the warning. KYL information does not appear to be an effective tool for reducing drinking and driving. Implications for prevention and future research are discussed.
ERIC Educational Resources Information Center
Zuzack, Christine A.
1997-01-01
Enhanced magnetic strip cards and "smart cards" offer varied service options to college students. Enhanced magnetic strip cards serve as cash cards and provide access to services. Smart cards, which resemble credit cards but contain a microchip, can be used as phone cards, bus passes, library cards, admission tickets, point-of-sale debit…
Assessment of DNA extracted from FTA® cards for use on the Illumina iSelect BeadChip
McClure, Matthew C; McKay, Stephanie D; Schnabel, Robert D; Taylor, Jeremy F
2009-01-01
Background As FTA® cards provide an ideal medium for the field collection of DNA we sought to assess the quality of genomic DNA extracted from this source for use on the Illumina BovineSNP50 iSelect BeadChip which requires unbound, relatively intact (fragment sizes ≥ 2 kb), and high-quality DNA. Bovine blood and nasal swab samples collected on FTA cards were extracted using the commercially available GenSolve kit with a minor modification. The call rate and concordance of genotypes from each sample were compared to those obtained from whole blood samples extracted by standard PCI extraction. Findings An ANOVA analysis indicated no significant difference (P > 0.72) in BovineSNP50 genotype call rate between DNA extracted from FTA cards by the GenSolve kit or extracted from whole blood by PCI. Two sample t-tests demonstrated that the DNA extracted from the FTA cards produced genotype call and concordance rates that were not different to those produced by assaying DNA samples extracted by PCI from whole blood. Conclusion We conclude that DNA extracted from FTA cards by the GenSolve kit is of sufficiently high quality to produce results comparable to those obtained from DNA extracted from whole blood when assayed by the Illumina iSelect technology. Additionally, we validate the use of nasal swabs as an alternative to venous blood or buccal samples from animal subjects for reliably producing high quality genotypes on this platform. PMID:19531223
Assessment of DNA extracted from FTA cards for use on the Illumina iSelect BeadChip.
McClure, Matthew C; McKay, Stephanie D; Schnabel, Robert D; Taylor, Jeremy F
2009-06-16
As FTA cards provide an ideal medium for the field collection of DNA we sought to assess the quality of genomic DNA extracted from this source for use on the Illumina BovineSNP50 iSelect BeadChip which requires unbound, relatively intact (fragment sizes >or= 2 kb), and high-quality DNA. Bovine blood and nasal swab samples collected on FTA cards were extracted using the commercially available GenSolve kit with a minor modification. The call rate and concordance of genotypes from each sample were compared to those obtained from whole blood samples extracted by standard PCI extraction. An ANOVA analysis indicated no significant difference (P > 0.72) in BovineSNP50 genotype call rate between DNA extracted from FTA cards by the GenSolve kit or extracted from whole blood by PCI. Two sample t-tests demonstrated that the DNA extracted from the FTA cards produced genotype call and concordance rates that were not different to those produced by assaying DNA samples extracted by PCI from whole blood. We conclude that DNA extracted from FTA cards by the GenSolve kit is of sufficiently high quality to produce results comparable to those obtained from DNA extracted from whole blood when assayed by the Illumina iSelect technology. Additionally, we validate the use of nasal swabs as an alternative to venous blood or buccal samples from animal subjects for reliably producing high quality genotypes on this platform.
Ikeda, Kayo; Ikawa, Kazuro; Yokoshige, Satoko; Yoshikawa, Satoshi; Morikawa, Norifumi
2014-12-01
A simple and sensitive gas chromatography-electron ionization-mass spectrometry (GC-EI-MS) method using dried plasma spot testing cards was developed for determination of valproic acid and gabapentin concentrations in human plasma from patients receiving in-home medical care. We have proposed that a simple, easy and dry sampling method is suitable for in-home medical patients for therapeutic drug monitoring. Therefore, in the present study, we used recently developed commercially available easy handling cards: Whatman FTA DMPK-A and Bond Elut DMS. In-home medical care patients can collect plasma using these simple kits. The spots of plasma on the cards were extracted into methanol and then evaporated to dryness. The residues were trimethylsilylated using N-methyl-N-trimethylsilyltrifluoroacetamide. For GC-EI-MS analysis, the calibration curves on both cards were linear from 10 to 200 µg/mL for valproic acid, and from 0.5 to 10 µg/mL for gabapentin. Intra- and interday precisions in plasma were both ≤13.0% (coefficient of variation), and the accuracy was between 87.9 and 112% for both cards within the calibration curves. The limits of quantification were 10 µg/mL for valproic acid and 0.5 µg/mL for gabapentin on both cards. We believe that the present method will be useful for in-home medical care. Copyright © 2014 John Wiley & Sons, Ltd.
Assessment of the RNASound RNA Sampling Card for the Preservation of Influenza Virus RNA
Lau, Hilda; Hurt, Aeron C.
2016-01-01
Shipping influenza virus specimens, isolates or purified RNA is normally conducted at ultra-low temperatures using dry ice to ensure minimal degradation of the samples but this is expensive and requires special packaging and shipping conditions. Therefore, alternative methods for shipping influenza viruses or RNA at ambient temperatures would be desirable. The RNASound RNA Sampling Card (FortiusBio LLC, San Diego, CA, USA) is a device that enables specimens or isolates to be applied to a card, whereby viruses are inactivated, while RNA is preserved and purified RNA can also easily be eluted. To evaluate this card, we applied influenza virus cell culture isolate supernatants to either the RNASound card or Whatman Grade No. 1 filter paper (GE Healthcare, Rydalmere, NSW, Australia) and compared the preservation to that of material stored in liquid form. Preservation was tested using influenza A and B viruses at two different storage temperatures [cool (2–8°C) or room temperature (18–22°C)] and these were compared with control material stored at -80°C, for 7, 14, or 28 days. The quality of the RNA recovered was assessed using real time RT-PCR and Sanger sequencing. The RNASound card was effective in preserving influenza RNA at room temperature for up to 28 days, with only a minor change in real-time RT-PCR cycle threshold values for selected gene targets when comparing between viruses applied to the card or stored at -80°C. Similar results were obtained with filter paper, whilst virus in liquid form performed the worst. Nevertheless, as the RNASound card also has the capability to inactivate viruses in addition to preserving RNA at room temperature for many weeks, this makes it feasible to send samples to laboratories using regular mail, and thus avoid the need for expensive shipping conditions requiring biohazard containers and dry ice. Moreover, the quick and simple RNA recovery from the RNASound card allows recipient labs to obtain RNA without the need for special reagents or equipment. PMID:27853455
Rare and Common Variants in CARD14, Encoding an Epidermal Regulator of NF-kappaB, in Psoriasis
Jordan, Catherine T.; Cao, Li; Roberson, Elisha D.O.; Duan, Shenghui; Helms, Cynthia A.; Nair, Rajan P.; Duffin, Kristina Callis; Stuart, Philip E.; Goldgar, David; Hayashi, Genki; Olfson, Emily H.; Feng, Bing-Jian; Pullinger, Clive R.; Kane, John P.; Wise, Carol A.; Goldbach-Mansky, Raphaela; Lowes, Michelle A.; Peddle, Lynette; Chandran, Vinod; Liao, Wilson; Rahman, Proton; Krueger, Gerald G.; Gladman, Dafna; Elder, James T.; Menter, Alan; Bowcock, Anne M.
2012-01-01
Psoriasis is a common inflammatory disorder of the skin and other organs. We have determined that mutations in CARD14, encoding a nuclear factor of kappa light chain enhancer in B cells (NF-kB) activator within skin epidermis, account for PSORS2. Here, we describe fifteen additional rare missense variants in CARD14, their distribution in seven psoriasis cohorts (>6,000 cases and >4,000 controls), and their effects on NF-kB activation and the transcriptome of keratinocytes. There were more CARD14 rare variants in cases than in controls (burden test p value = 0.0015). Some variants were only seen in a single case, and these included putative pathogenic mutations (c.424G>A [p.Glu142Lys] and c.425A>G [p.Glu142Gly]) and the generalized-pustular-psoriasis mutation, c.413A>C (p.Glu138Ala); these three mutations lie within the coiled-coil domain of CARD14. The c.349G>A (p.Gly117Ser) familial-psoriasis mutation was present at a frequency of 0.0005 in cases of European ancestry. CARD14 variants led to a range of NF-kB activities; in particular, putative pathogenic variants led to levels >2.5× higher than did wild-type CARD14. Two variants (c.511C>A [p.His171Asn] and c.536G>A [p.Arg179His]) required stimulation with tumor necrosis factor alpha (TNF-α) to achieve significant increases in NF-kB levels. Transcriptome profiling of wild-type and variant CARD14 transfectants in keratinocytes differentiated probably pathogenic mutations from neutral variants such as polymorphisms. Over 20 CARD14 polymorphisms were also genotyped, and meta-analysis revealed an association between psoriasis and rs11652075 (c.2458C>T [p.Arg820Trp]; p value = 2.1 × 10−6). In the two largest psoriasis cohorts, evidence for association increased when rs11652075 was conditioned on HLA-Cw∗0602 (PSORS1). These studies contribute to our understanding of the genetic basis of psoriasis and illustrate the challenges faced in identifying pathogenic variants in common disease. PMID:22521419
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...
Small passenger car transmission test: Mercury Lynx ATX transmission
NASA Technical Reports Server (NTRS)
Bujold, M. P.
1981-01-01
The testing of a Mercury Lynx automatic transmission is reported. The transmission was tested in accordance with a passenger car automatic transmission test code (SAE J65lb) which required drive performance, coast performance, and no load test conditions. Under these conditions, the transmission attained maximum efficiencies in the mid-ninety percent range both for drive performance test and coast performance tests. The torque, speed, and efficiency curves are presented, which provide the complete performance characteristics for the Mercury Lynx automatic transmission.
A Spondee Recognition Test for Young Hearing-Impaired Children
ERIC Educational Resources Information Center
Cramer, Kathryn D.; Erber, Norman P.
1974-01-01
An auditory test of 10 spondaic words recorded on Language Master cards was presented monaurally, through insert receivers to 58 hearing-impaired young children to evaluate their ability to recognize familiar speech material. (MYS)
Effects of music therapy and distraction cards on pain relief during phlebotomy in children.
Aydin, Diler; Sahiner, Nejla Canbulat
2017-02-01
To investigate three different distraction methods (distraction cards, listening to music, and distraction cards + music) on pain and anxiety relief in children during phlebotomy. This study was a prospective, randomized, controlled trial. The sample consisted of children aged 7 to 12years who required blood tests. The children were randomized into four groups, distraction cards, music, distraction cards + music, and controls. Data were obtained through face-to-face interviews with the children, their parents, and the observer before and after the procedure. The children's pain levels were assessed and reported by the parents and observers, and the children themselves who self-reported using Wong-Baker FACES. The children's anxiety levels were also assessed using the Children's Fear Scale. Two hundred children (mean age: 9.01±2.35years) were included. No difference was found between the groups in the self, parent, and observer reported procedural pain levels (p=0.72, p=0.23, p=0.15, respectively). Furthermore, no significant differences were observed between groups in procedural child anxiety levels according to the parents and observer (p=0.092, p=0.096, respectively). Pain and anxiety relief was seen in all three methods during phlebotomy; however, no statistically significant difference was observed. Copyright © 2016 Elsevier Inc. All rights reserved.
[Application of patient card technology to health care].
Sayag, E; Danon, Y L
1995-03-15
The potential benefits of patient card technology in improving management and delivery of health services have been explored. Patient cards can be used for numerous applications and functions: as a means of identification, as a key for an insurance payment system, and as a communication medium. Advanced card technologies allow for the storage of data on the card, creating the possibility of a comprehensive and portable patient record. There are many types of patient cards: paper or plastic cards, microfilm cards, bar-code cards, magnetic-strip cards and integrated circuit smart-cards. Choosing the right card depends on the amount of information to be stored, the degree of security required and the cost of the cards and their supporting infrastructure. Problems with patient cards are related to storage capacity, backup and data consistency, access authorization and ownership and compatibility. We think it is worth evaluating the place of patient card technology in the delivery of health services in Israel.
ERIC Educational Resources Information Center
McGee, Glenn W.
What the Illinois Goal Assessment Program (IGAP) test actually tests and the consequences of these tests for funding decisions were studied with a random sample of 100 school districts in the Cook County suburbs of Chicago. Eighth-grade IGAP scores for reading were obtained from the state report card, a document prepared by each school district…
Appointment at Palmer Appointment at Fairbanks Schedule My Road Test Road Test Wait List DRIVERS Get My Card Track My ID or License Practice Knowledge Test Register to Vote VEHICLES Renew My Registration Road Test Road Test Wait List Locations & Hours Office Hours Check Wait Times Dealer and Fleet
Automatic Radiated Susceptibility Test System for Payload Equipment
NASA Technical Reports Server (NTRS)
Ngo, Hoai T.; Sturman, John C.; Sargent, Noel B.
1995-01-01
An automatic radiated susceptibility test system (ARSTS) was developed for NASA Lewis Research Center's Electro-magnetic Interference laboratory. According to MSFC-SPEC 521B, any electrical or electronic equipment that will be transported by the spacelab and space shuttle must be tested for susceptibility to electromagnetic interference. This state-of-the-art automatic test system performs necessary calculations; analyzes, processes, and records a great quantity of measured data; and monitors the equipment being tested in real-time and with minimal user intervention. ARSTS reduces costly test time, increases test accuracy, and provides reliable test results.
Evaluation of the new Vitek 2 ANC card for identification of medically relevant anaerobic bacteria.
Mory, Francine; Alauzet, Corentine; Matuszeswski, Céline; Riegel, Philippe; Lozniewski, Alain
2009-06-01
Of 261 anaerobic clinical isolates tested with the new Vitek 2 ANC card, 257 (98.5%) were correctly identified at the genus level. Among the 251 strains for which identification at the species level is possible with regard to the ANC database, 217 (86.5%) were correctly identified at the species level. Two strains (0.8%) were not identified, and eight were misidentified (3.1%). Of the 21 strains (8.1%) with low-level discrimination results, 14 were correctly identified at the species level by using the recommended additional tests. This system is a satisfactory new automated tool for the rapid identification of most anaerobic bacteria isolated in clinical laboratories.
Novel Pseudomonas fluorescens Septic Sacroiliitis in a Healthy Soldier
2013-08-01
Clin Microbiol 2007; 45(11): 3774–6. 8. Zbinden A, Böttger EC, Bosshard PP, Zbinden R: Evaluation of the colorimetric VITEK 2 card for identification...Böddinghaus B, Altwegg M, Böttger EC: 16S rRNA gene sequencing versus the API 20 NE system and the VITEK 2 ID-GNB card for identification of...techniques beyond routine culture and susceptibility testing should also be considered to account for less commonly seen pathogens. Although optimal
Mated Fingerprint Card Pairs 2 (MFCP2)
National Institute of Standards and Technology Data Gateway
NIST Mated Fingerprint Card Pairs 2 (MFCP2) (Web, free access) NIST Special Database 14 is being distributed for use in development and testing of automated fingerprint classification and matching systems on a set of images which approximate a natural horizontal distribution of the National Crime Information Center (NCIC) fingerprint classes. A newer version of the compression/decompression software on the CDROM can be found at the website http://www.nist.gov/itl/iad/ig/nigos.cfm as part of the NBIS package.
Horowitz-Kraus, Tzipi
2014-01-01
Adolescents with dyslexia exhibit well-established impairments in executive abilities. The Wisconsin card sorting test (WCST) is an executive test that yields surprisingly inconsistent results with this population. The current study aimed to shed light on the contradictory findings in the literature regarding the performance levels by individuals with dyslexia in WCST. We used a computerized-WCST (named the 'Madrid-Card Sorting Test') assessing executive functions using the Event-Related Potentials (ERPs) methodology. Adolescents with dyslexia exhibited a higher error rate and slower reaction times. This was most evident in the later trials of the series. However, differences in ERPs between the two groups were found only in the "target-locked" conditions, where individuals with dyslexia displayed decreased ERP components (N100, P300) compared to skilled readers. The changes between the groups in the "shift" compared to the "stay" conditions suggest the central role of working memory both in basic (e.g., shifting) and higher order (e.g., reading) processes in individuals with dyslexia. These findings suggest the central role of working memory both in basic (e.g., shifting) and higher order (e.g., reading) processes in individuals with dyslexia. The intact shifting mechanism and the working memory deficit may guide the building of more efficient intervention programs for individuals with dyslexia in the future.
The Associate Principal Astronomer for AI Management of Automatic Telescopes
NASA Technical Reports Server (NTRS)
Henry, Gregory W.
1998-01-01
This research program in scheduling and management of automatic telescopes had the following objectives: 1. To field test the 1993 Automatic Telescope Instruction Set (ATIS93) programming language, which was specifically developed to allow real-time control of an automatic telescope via an artificial intelligence scheduler running on a remote computer. 2. To develop and test the procedures for two-way communication between a telescope controller and remote scheduler via the Internet. 3. To test various concepts in Al scheduling being developed at NASA Ames Research Center on an automatic telescope operated by Tennessee State University at the Fairborn Observatory site in southern Arizona. and 4. To develop a prototype software package, dubbed the Associate Principal Astronomer, for the efficient scheduling and management of automatic telescopes.
Management of a TIFS System: Organizing Tests with Instructional Feedback on Slides.
ERIC Educational Resources Information Center
Brown, F. Dale; Mitchell, Thomas O.
1980-01-01
Presents three components of the tests with instructional feedback on slides system (TIFS), the needs of the three, background on the production of the test item reference card, and the advantage of the system for both instructor and student. (MER)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, Darren M.
Sandia National Laboratories has tested and evaluated Geotech Smart24 data acquisition system with active Fortezza crypto card data signing and authentication. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of the Geotech Smart24 digitizer with a Fortezza PCMCIA cryptomore » card actively implementing the signing of data packets. The results of this evaluation were compared to relevant specifications provided within manufacturer's documentation notes. The tests performed were chosen to demonstrate different performance aspects of the digitizer under test. The performance aspects tested include determining noise floor, least significant bit (LSB), dynamic range, cross-talk, relative channel-to-channel timing, time-tag accuracy, analog bandwidth and calibrator performance.« less
Solutions for acceleration measurement in vehicle crash tests
NASA Astrophysics Data System (ADS)
Dima, D. S.; Covaciu, D.
2017-10-01
Crash tests are useful for validating computer simulations of road traffic accidents. One of the most important parameters measured is the acceleration. The evolution of acceleration versus time, during a crash test, form a crash pulse. The correctness of the crash pulse determination depends on the data acquisition system used. Recommendations regarding the instrumentation for impact tests are given in standards, which are focused on the use of accelerometers as impact sensors. The goal of this paper is to present the device and software developed by authors for data acquisition and processing. The system includes two accelerometers with different input ranges, a processing unit based on a 32-bit microcontroller and a data logging unit with SD card. Data collected on card, as text files, is processed with a dedicated software running on personal computers. The processing is based on diagrams and includes the digital filters recommended in standards.
Testing novel patient financial incentives to increase breast cancer screening.
Merrick, Elizabeth Levy; Hodgkin, Dominic; Horgan, Constance M; Lorenz, Laura S; Panas, Lee; Ritter, Grant A; Kasuba, Paul; Poskanzer, Debra; Nefussy, Renee Altman
2015-11-01
To examine the effects of 3 types of low-cost financial incentives for patients, including a novel "person-centered" approach on breast cancer screening (mammogram) rates. Randomized controlled trial with 4 arms: 3 types of financial incentives ($15 gift card, entry into lottery for $250 gift card, and a person-centered incentive with choice of $15 gift card or lottery) and a control group. Sample included privately insured Tufts Health Plan members in Massachusetts who were women aged 42 to 69 years with no mammogram claim in ≥ 2.6 years. A sample of 4700 eligible members were randomized to 4 study arms. The control group received a standard reminder letter and the incentive groups received a reminder letter plus an incentive offer for obtaining a mammogram within the next 4 months. Bivariate tests and multivariate logistic regression were used to assess the incentives' impact on mammogram receipt. Data were analyzed for 4427 members (after exclusions such as undeliverable mail). The percent of members receiving a mammogram during the study was 11.7% (gift card), 12.1% (lottery), 13.4% (person-centered/choice), and 11.9% (controls). Differences were not statistically significant in bivariate or multivariate full-sample analyses. In exploratory subgroup analyses of members with a mammogram during the most recent year prior to the study-defined gap, person-centered incentives were associated with a higher likelihood of mammogram receipt. None of the low-cost incentives tested had a statistically significant effect on mammogram rates in the full sample. Exploratory findings for members who were more recently screened suggest that they may be more responsive to person-centered incentives.
Gema Díaz-Blancat; Juan García-Prieto; Fernando Maestú; Francisco Barceló
2018-05-01
One common assumption has been that prefrontal executive control is mostly required for target detection (Posner and Petersen in Ann Rev Neurosci 13:25-42, 1990). Alternatively, cognitive control has also been related to anticipatory updating of task-set (contextual) information, a view that highlights proactive control processes. Frontoparietal cortical networks contribute to both proactive control and reactive target detection, although their fast dynamics are still largely unexplored. To examine this, we analyzed rapid magnetoencephalographic (MEG) source activations elicited by task cues and target cards in a task-cueing analogue of the Wisconsin Card Sorting Test. A single-task (color sorting) condition with equivalent perceptual and motor demands was used as a control. Our results revealed fast, transient and largely switch-specific MEG activations across frontoparietal and cingulo-opercular regions in anticipation of target cards, including (1) early (100-200 ms) cue-locked MEG signals at visual, temporo-parietal and prefrontal cortices of the right hemisphere (i.e., calcarine sulcus, precuneus, inferior frontal gyrus, anterior insula and supramarginal gyrus); and (2) later cue-locked MEG signals at the right anterior and posterior insula (200-300 ms) and the left temporo-parietal junction (300-500 ms). In all cases larger MEG signal intensity was observed in switch relative to repeat cueing conditions. Finally, behavioral restart costs and test scores of working memory capacity (forward digit span) correlated with cue-locked MEG activations at key nodes of the frontoparietal network. Together, our findings suggest that proactive cognitive control of task rule updating can be fast and transiently implemented within less than a second and in anticipation of target detection.
Development of a battery of functional tests for low vision.
Dougherty, Bradley E; Martin, Scott R; Kelly, Corey B; Jones, Lisa A; Raasch, Thomas W; Bullimore, Mark A
2009-08-01
We describe the development and evaluation of a battery of tests of functional visual performance of everyday tasks intended to be suitable for assessment of low vision patients. The functional test battery comprises-Reading rate: reading aloud 20 unrelated words for each of four print sizes (8, 4, 2, & 1 M); Telephone book: finding a name and reading the telephone number; Medicine bottle label: reading the name and dosing; Utility bill: reading the due date and amount due; Cooking instructions: reading cooking time on a food package; Coin sorting: making a specified amount from coins placed on a table; Playing card recognition: identifying denomination and suit; and Face recognition: identifying expressions of printed, life-size faces at 1 and 3 m. All tests were timed except face and playing card recognition. Fourteen normally sighted and 24 low vision subjects were assessed with the functional test battery. Visual acuity, contrast sensitivity, and quality of life (National Eye Institute Visual Function Questionnaire 25 [NEI-VFQ 25]) were measured and the functional tests repeated. Subsequently, 23 low vision patients participated in a pilot randomized clinical trial with half receiving low vision rehabilitation and half a delayed intervention. The functional tests were administered at enrollment and 3 months later. Normally sighted subjects could perform all tasks but the proportion of trials performed correctly by the low vision subjects ranged from 35% for face recognition at 3 m, to 95% for the playing card identification. On average, low vision subjects performed three times slower than the normally sighted subjects. Timed tasks with a visual search component showed poorer repeatability. In the pilot clinical trial, low vision rehabilitation produced the greatest improvement for the medicine bottle and cooking instruction tasks. Performance of patients on these functional tests has been assessed. Some appear responsive to low vision rehabilitation.
BMI Health Report Cards: Parents' Perceptions and Reactions.
Jones, Marla; Huffer, Cassie; Adams, Tom; Jones, Logan; Church, Bryan
2017-12-01
In 2003, Arkansas became the first state to require body mass index (BMI) testing in public schools to raise awareness of the growing obesity epidemic among children and adolescents. Limited information exists regarding the effectiveness of school-based BMI screening programs. The purpose of this study was to determine if BMI health report cards affected parents' knowledge or actions regarding their child's health and to determine the accuracy of parents' perceptions of their child as underweight, normal weight, or overweight according to their child's BMI. A questionnaire was developed with the help of physical educators, pediatricians, and exercise scientists to determine parents' perceptions and behaviors regarding BMI report cards. The questionnaire was distributed to parents/guardians of children who sought medical care at two pediatrician's offices in Arkansas. Based on responses to survey questions, parents are not making changes to their child's diet and exercise habits if their child is classified as "at risk" or "overweight." However, parents did report that BMI health report cards are influencing their knowledge about their child's health. The majority of parents in the study (approximately 66%) did not accurately perceive their child's BMI category.
LabVIEW Interface for PCI-SpaceWire Interface Card
NASA Technical Reports Server (NTRS)
Lux, James; Loya, Frank; Bachmann, Alex
2005-01-01
This software provides a LabView interface to the NT drivers for the PCISpaceWire card, which is a peripheral component interface (PCI) bus interface that conforms to the IEEE-1355/ SpaceWire standard. As SpaceWire grows in popularity, the ability to use SpaceWire links within LabVIEW will be important to electronic ground support equipment vendors. In addition, there is a need for a high-level LabVIEW interface to the low-level device- driver software supplied with the card. The LabVIEW virtual instrument (VI) provides graphical interfaces to support all (1) SpaceWire link functions, including message handling and routing; (2) monitoring as a passive tap using specialized hardware; and (3) low-level access to satellite mission-control subsystem functions. The software is supplied in a zip file that contains LabVIEW VI files, which provide various functions of the PCI-SpaceWire card, as well as higher-link-level functions. The VIs are suitably named according to the matching function names in the driver manual. A number of test programs also are provided to exercise various functions.
Temesi, David; Swales, John; Keene, Warren; Dick, Samuel
2013-03-25
Procedures for drug monitoring based on Dried Blood Spot (DBS) sampling are gaining acceptance for an increasing number of clinical and preclinical applications, where ease of use, small sample requirement, and improved sample stability have been shown to offer advantages over blood tube sampling. However, to-date, the vast majority of this work has described the analysis of well characterized drugs. Using amitriptyline, clozapine, and their potentially labile N-oxide metabolites as model compounds, we consider the merits of using DBS for discovery pharmacokinetic (PK) studies where the metabolic fate of test compounds are often unknown. Both N-oxide metabolites reverted to parent compound under standard drying (2hr) and extraction conditions. Card type significantly affected the outcome, with 14% and 22% degradation occurring for clozapine-N-oxide and amitriptyline-N-oxide on a brand of untreated DBS cards, compared to 59 and 88% on a brand of treated DBS cards. Enrichment of the parent compound ex vivo leads to overestimation of circulating blood concentration and inaccurate determination of the PK profile. Copyright © 2012 Elsevier B.V. All rights reserved.
Use and diversion of medical marijuana among adults admitted to inpatient psychiatry.
Nussbaum, Abraham M; Thurstone, Christian; McGarry, Laurel; Walker, Brendan; Sabel, Allison L
2015-03-01
Marijuana use is associated with anxiety, depressive, psychotic, neurocognitive, and substance use disorders. Many US states are legalizing marijuana for medical uses. To determine the prevalence of medical marijuana use and diversion among psychiatric inpatients in Colorado. Some 623 participants (54.6% male) responded to an anonymous 15-item discharge survey that assessed age, gender, marijuana use, possession of a medical marijuana card, diversion of medical marijuana, perceived substance use problems, and effects of marijuana use. Univariate statistics were used to characterize participants and their responses. Chi-square tests assessed factors associated with medical marijuana registration. Of the total number of respondents, 282 (47.6%) reported using marijuana in the last 12 months and 60 (15.1%) reported having a marijuana card. In comparison to survey respondents who denied having a medical marijuana card, those respondents with a medical marijuana card were more likely to have initiated use before the age of 25, to be male, to have used marijuana in the last 12 months, and to have used at least 20 days in the past month. 133 (24.1%) respondents reported that someone with a medical marijuana card had shared or sold medical marijuana to them; 24 (41.4%) of respondents with a medical marijuana card reported ever having shared or sold their medical marijuana. Medical marijuana use is much more prevalent among adults hospitalized with a psychiatric emergency than in the general population; diversion is common. Further studies which correlate amount, dose, duration, and strain of use with particular psychiatric disorders are needed.
ERIC Educational Resources Information Center
Gutl, Christian; Lankmayr, Klaus; Weinhofer, Joachim; Hofler, Margit
2011-01-01
Research in automated creation of test items for assessment purposes became increasingly important during the recent years. Due to automatic question creation it is possible to support personalized and self-directed learning activities by preparing appropriate and individualized test items quite easily with relatively little effort or even fully…
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Uniform test methods for the measurement of energy consumption and water consumption of automatic commercial ice makers. 431.134 Section 431.134 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Automatic Commercial Ice Makers Test...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Uniform test methods for the measurement of energy consumption and water consumption of automatic commercial ice makers. 431.134 Section 431.134 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Automatic Commercial Ice Makers Test...
[New electronic data carriers in Bosnia-Herzegovina].
Masić, I; Pandza, H; Knezević, Z; Toromanović, S
1999-01-01
Bosnia and Herzegovina has been developing new Health Care System based on Electronic Registration Card. Developing countries proceeded from the manual and semiautomatic method of medical data processing to the new method of entering, storage, transfer, searching and protection of data using electronic equipment. Currently, many European countries have developed a Medical Card Based Electronic Information System. Both technologies offer the advantages and disadvantages. Three types of electronic card are currently in use: Hybrid Card, Smart Card and Laser Card. Hybrid Card offers characteristics of both Smart Card and Laser Card. The differences among these cards, such as a capacity, total price, price per byte, security system are discussed here. The dilemma is, which card should be used as a data carrier. The Electronic Family Registration Card is a question of strategic interest for B&H, but also a big investment. We should avoid the errors of other countries that have been developing card-based system. In this article we present all mentioned cards and compare advantages and disadvantages of different technologies.
Methodology for Constructing a Modernization Roadmap for Air Force Automatic Test Systems
2012-01-01
Constructing a Modernization Roadmap for Air Force Automatic Test Systems Lionel A. Galway , Rachel Rue, James M. Masters, Ben D. Van Roo, Manuel...constructing a modernization roadmap for Air Force automatic test systems / Lionel A. Galway ... [et al.]. p. cm. Includes bibliographical...references. ISBN 978-0-8330-5899-7 (pbk. : alk. paper) 1. United States. Air Force—Weapons systems—Testing. I. Galway , Lionel A., 1950- UG633.M3445
10 CFR 431.135 - Units to be tested.
Code of Federal Regulations, 2011 CFR
2011-01-01
... EQUIPMENT Automatic Commercial Ice Makers Test Procedures § 431.135 Units to be tested. For each basic model of automatic commercial ice maker selected for testing, a sample of sufficient size shall be selected...
Mechanization of Cataloging Procedures *
Kilgour, Frederick G.
1965-01-01
The Columbia-Harvard-Yale Medical Libraries Computerization Project has put into operation its mechanized procedure for the production of catalog cards. Cards produced are in final form ready to be filed into a card catalog. Catalogers prepare copy on a worksheet from which punched cards are punched. An IBM 1401 computer processes the decklets of punched cards on magnetic tape to produce the expanded decklets of punched cards needed to print the various packs of catalog cards required to go into different catalogs. Next, the computer punches the expanded decklets of cards to operate an 870 Document Writer, which types out the catalog cards in final form. Cost of cards ready to file is 12.5 cents per card. Images PMID:14271110
Luo, Hongxue; Du, Hui; Maurer, Kathryn; Belinson, Jerome L; Wang, Guixiang; Liu, Zhihong; Zhang, Lijie; Zhou, Yanqiu; Wang, Chun; Tang, Jinlong; Qu, Xinfeng; Wu, Ruifang
2016-01-01
Determine the ability of the Cobas 4800 assay to detect high-risk human papillomavirus (HrHPV) and high-grade cervical lesions when using cervico-vaginal samples applied to liquid medium and solid media cards compared to a direct cervical sample. Two cervico-vaginal specimens (pseudo self-collected) were obtained from 319 women. One was applied to an iFTA Card (FTA) then the brush placed in liquid-based medium (LSELF); the other was applied to a new solid media: POI card (POI). The clinical performance of Cobas4800 assay using the three aforementioned specimens was compared to direct collected endocervical specimens in liquid media (LDOC). The overall agreements of HrHPV detection were 84.2% (LSELF vs. LDOC), 81.0% (FTA vs. LDOC), and 82.3% (POI vs. LDOC). LSELF, FTA and POI identified 98.0%, 79.6%, and 97.5% positive cases of LDOC. Sensitivity to identify CIN2+ were 98.4% (LSELF), 73.8% (FTA), 95.1% (POI), and 93.4% (LDOC) respectively. FTA had 78.1% and 90.4% agreement with the LSELF samples for all HrHPV and HPV16/18 detection respectively, while POI had 91.6% for both. Cobas4800 HPV test combined with cervico-vaginal specimens applied to both liquid media and POI solid card are accurate to detect HrHPV infection and high-grade cervical lesions as compared with direct endocervical samples in liquid media.
Luo, Hongxue; Du, Hui; Maurer, Kathryn; Belinson, Jerome L.; Wang, Guixiang; Liu, Zhihong; Zhang, Lijie; Zhou, Yanqiu; Wang, Chun; Tang, Jinlong; Qu, Xinfeng; Wu, Ruifang
2016-01-01
Objectives Determine the ability of the Cobas 4800 assay to detect high-risk human papillomavirus (HrHPV) and high-grade cervical lesions when using cervico-vaginal samples applied to liquid medium and solid media cards compared to a direct cervical sample. Methods Two cervico-vaginal specimens (pseudo self-collected) were obtained from 319 women. One was applied to an iFTA Card (FTA) then the brush placed in liquid-based medium (LSELF); the other was applied to a new solid media: POI card (POI). The clinical performance of Cobas4800 assay using the three aforementioned specimens was compared to direct collected endocervical specimens in liquid media (LDOC). Results The overall agreements of HrHPV detection were 84.2% (LSELF vs. LDOC), 81.0% (FTA vs. LDOC), and 82.3% (POI vs. LDOC). LSELF, FTA and POI identified 98.0%, 79.6%, and 97.5% positive cases of LDOC. Sensitivity to identify CIN2+ were 98.4% (LSELF), 73.8% (FTA), 95.1% (POI), and 93.4% (LDOC) respectively. FTA had 78.1% and 90.4% agreement with the LSELF samples for all HrHPV and HPV16/18 detection respectively, while POI had 91.6% for both. Conclusions Cobas4800 HPV test combined with cervico-vaginal specimens applied to both liquid media and POI solid card are accurate to detect HrHPV infection and high-grade cervical lesions as compared with direct endocervical samples in liquid media. PMID:26828360
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lawrence, J.D.
1970-03-12
The Control Data 405 card reader, modified by the Control Data 3649 card read controller, is the primary mechanism for transferring information from a deck of punched cards into the CDC 6600 and CDC 7600 computers of the LLL Octopus system. The card reader operates at a maximum rate of 1200 cards per minute. A description of the card reader and its operation is given. A discussion of formates is included. (RWR)
Towards a Framework for Generating Tests to Satisfy Complex Code Coverage in Java Pathfinder
NASA Technical Reports Server (NTRS)
Staats, Matt
2009-01-01
We present work on a prototype tool based on the JavaPathfinder (JPF) model checker for automatically generating tests satisfying the MC/DC code coverage criterion. Using the Eclipse IDE, developers and testers can quickly instrument Java source code with JPF annotations covering all MC/DC coverage obligations, and JPF can then be used to automatically generate tests that satisfy these obligations. The prototype extension to JPF enables various tasks useful in automatic test generation to be performed, such as test suite reduction and execution of generated tests.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Avramova, Maria; Blyth, Taylor S.; Salko, Robert K.
This document describes how to make a CTF input deck. A CTF input deck is organized into Card Groups and Cards. A Card Group is a collection of Cards. A Card is defined as a line of input. Each Card may contain multiple data. A Card is terminated by making a new line.
29 CFR 4.123 - Administrative limitations, variances, tolerances, and exemptions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... servicing of cards (including credit cards, debit cards, purchase cards, smart cards, and similar card... military personnel in buying and selling homes (which shall not include actual moving or storage of...
Sensitizing Undergraduates to Potential Inaccuracies in Projective Test Interpretation.
ERIC Educational Resources Information Center
Barret, Robert L.; Wachowiak, Dale G.
This paper describes a methodology developed to provide undergraduate students with direct experience in the process of impressionistic test interpretation. In the experiential exercise, students were shown Thematic Apperception Test cards and then read the responses given by an anonymous client. A discussion of the process by which the students…
Test program for 4-K memory card, JOLT microprocessor
NASA Technical Reports Server (NTRS)
Lilley, R. W.
1976-01-01
A memory test program is described for use with the JOLT microcomputer 4,096-word memory board used in development of an Omega navigation receiver. The program allows a quick test of the memory board by cycling the memory through all possible bit combinations in all words.
Clipman, Steven J; Henderson-Frost, Josephine; Fu, Katherine Y; Bern, Caryn; Flores, Jorge; Gilman, Robert H
2018-01-01
About 20-30% of people infected with Chagas disease present with chronic Chagas cardiomyopathy (CCC), the most serious and frequent manifestation of the disease, while others remain asymptomatic and often do not experience Chagas-specific mortality. It is not currently well understood what causes these differential disease outcomes, but a genetic predisposition within the host could play an important role. This study examined variants in the NLRP1, CARD, and CASP1 inflammasome genes among 62 T. cruzi seropositive patients from Bolivia (38 cases with CCC and 24 asymptomatic controls) to uncover associations with CCC. All subjects underwent a complete medical examination including electrocardiogram (EKG) and echocardiogram. After genotype calling and quality control filtering with exclusion of 3 cases and 3 controls, association analysis was performed across 76 directly genotyped SNPs in NLRP1, CARD, and CASP1 genes, adjusting for age, sex, and population stratification. One SNP (rs11651270; Bonferroni-corrected p = 0.036) corresponding to a missense mutation in NLPR1 was found to be significant after adjustment for multiple testing, and a suggestive association was seen in CARD11 (rs6953573; Bonferroni-corrected p = 0.060). Although limited by sample size, the study results suggest variations in the inflammasome, particularly in NLRP1 and CARD11, may be associated with CCC.
NASA Astrophysics Data System (ADS)
Romaniuk, Ryszard S.
2013-10-01
Accelerator science and technology is one of a key enablers of the developments in the particle physic, photon physics and also applications in medicine and industry. The paper presents a digest of the research results in the domain of accelerator science and technology in Europe, shown during the realization of CARE (Coordinated Accelerator R&D), EuCARD (European Coordination of Accelerator R&D) and during the national annual review meeting of the TIARA - Test Infrastructure of European Research Area in Accelerator R&D. The European projects on accelerator technology started in 2003 with CARE. TIARA is an European Collaboration of Accelerator Technology, which by running research projects, technical, networks and infrastructural has a duty to integrate the research and technical communities and infrastructures in the global scale of Europe. The Collaboration gathers all research centers with large accelerator infrastructures. Other ones, like universities, are affiliated as associate members. TIARA-PP (preparatory phase) is an European infrastructural project run by this Consortium and realized inside EU-FP7. The paper presents a general overview of CARE, EuCARD and especially TIARA activities, with an introduction containing a portrait of contemporary accelerator technology and a digest of its applications in modern society. CARE, EuCARD and TIARA activities integrated the European accelerator community in a very effective way. These projects are expected very much to be continued.
Henderson-Frost, Josephine; Fu, Katherine Y.; Bern, Caryn; Flores, Jorge; Gilman, Robert H.
2018-01-01
About 20–30% of people infected with Chagas disease present with chronic Chagas cardiomyopathy (CCC), the most serious and frequent manifestation of the disease, while others remain asymptomatic and often do not experience Chagas-specific mortality. It is not currently well understood what causes these differential disease outcomes, but a genetic predisposition within the host could play an important role. This study examined variants in the NLRP1, CARD, and CASP1 inflammasome genes among 62 T. cruzi seropositive patients from Bolivia (38 cases with CCC and 24 asymptomatic controls) to uncover associations with CCC. All subjects underwent a complete medical examination including electrocardiogram (EKG) and echocardiogram. After genotype calling and quality control filtering with exclusion of 3 cases and 3 controls, association analysis was performed across 76 directly genotyped SNPs in NLRP1, CARD, and CASP1 genes, adjusting for age, sex, and population stratification. One SNP (rs11651270; Bonferroni-corrected p = 0.036) corresponding to a missense mutation in NLPR1 was found to be significant after adjustment for multiple testing, and a suggestive association was seen in CARD11 (rs6953573; Bonferroni-corrected p = 0.060). Although limited by sample size, the study results suggest variations in the inflammasome, particularly in NLRP1 and CARD11, may be associated with CCC. PMID:29438387
A Mechanism for Anonymous Credit Card Systems
NASA Astrophysics Data System (ADS)
Tamura, Shinsuke; Yanase, Tatsuro
This paper proposes a mechanism for anonymous credit card systems, in which each credit card holder can conceal individual transactions from the credit card company, while enabling the credit card company to calculate the total expenditures of transactions of individual card holders during specified periods, and to identify card holders who executed dishonest transactions. Based on three existing mechanisms, i.e. anonymous authentication, blind signature and secure statistical data gathering, together with implicit transaction links proposed here, the proposed mechanism enables development of anonymous credit card systems without assuming any absolutely trustworthy entity like tamper resistant devices or organizations faithful both to the credit card company and card holders.
Turning a Private Label Bank Card into a Multi-function Campus ID Card.
ERIC Educational Resources Information Center
James, Thomas G.; Norwood, Bill R.
1991-01-01
This article describes the development at Florida State University of the Seminole ACCESS card, which functions simultaneously as a bank automated teller machine card, a student identification card, and a debit card. Explained are the partnership between the university and the bank charge card center, funding system, technologies involved, and…
Zhou, P; Chou, J; Olea, R S; Yuan, J; Wagner, G
1999-09-28
Direct recruitment and activation of caspase-9 by Apaf-1 through the homophilic CARD/CARD (Caspase Recruitment Domain) interaction is critical for the activation of caspases downstream of mitochondrial damage in apoptosis. Here we report the solution structure of the Apaf-1 CARD domain and its surface of interaction with caspase-9 CARD. Apaf-1 CARD consists of six tightly packed amphipathic alpha-helices and is topologically similar to the RAIDD CARD, with the exception of a kink observed in the middle of the N-terminal helix. By using chemical shift perturbation data, the homophilic interaction was mapped to the acidic surface of Apaf-1 CARD centered around helices 2 and 3. Interestingly, a significant portion of the chemically perturbed residues are hydrophobic, indicating that in addition to the electrostatic interactions predicted previously, hydrophobic interaction is also an important driving force underlying the CARD/CARD interaction. On the basis of the identified functional residues of Apaf-1 CARD and the surface charge complementarity, we propose a model of CARD/CARD interaction between Apaf-1 and caspase-9.
Responses of Chinese University Students to the Thematic Apperception Test
ERIC Educational Resources Information Center
Han, Elizabeth Yeo-hsien
1974-01-01
Murray's original Thematic Apperception Test (TAT), Cards I to XX, was administered in two sessions to 80 Chinese male and female undergraduate students at the National Taiwan Normal University. The results are compared with American averages. (Author/JH)
The Role of Item Models in Automatic Item Generation
ERIC Educational Resources Information Center
Gierl, Mark J.; Lai, Hollis
2012-01-01
Automatic item generation represents a relatively new but rapidly evolving research area where cognitive and psychometric theories are used to produce tests that include items generated using computer technology. Automatic item generation requires two steps. First, test development specialists create item models, which are comparable to templates…
Kim, Seon Young; Kim, Hyunjin; Park, Yeongchun; Lim, Jinsook; Kim, Jimyung; Koo, Sun Hoe; Kwon, Gye Cheol
2017-06-01
On-site drugs of abuse testing devices have undergone continuous improvement. We evaluated three devices with different designs: an automated reader, the Multi-Drug Screen Test Device with DxLINK (DxLINK; Innovacon, Alere, San Diego, USA) and two colorimetric immunoassays, the One Step Multi-Line Screen Panel with Integrated E-Z Split Key Cup II (E-Z Cup; Innovacon, Alere) and the One Step Multi-Drug Screen Panel card (Multi4 card; Alere, Abon Biopharm, Hangzhou, China). Eleven drugs [amphetamine, secobarbital, oxazepam, buprenorphine, benzoylecgonine, methylenedioxymethamphetamine (MDMA), 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC), methamphetamine, methadone, morphine and nortriptyline] were tested using the DxLINK and E-Z Cup. Four drugs (benzoylecgonine, THC, methamphetamine and morphine) were tested using the Multi4 card using control materials (Detectabuse Stat-Skreen; Biochemical Diagnostics, Edgewood, NY, USA). The concentrations (-50%, -25%, +25%, +50% and 3× cut-off values) of the control materials were confirmed by mass spectrometry. Concordance rates were calculated around cut-offs. All devices showed high overall agreement rates of >90% with a few exceptions: the DxLINK exhibited lower sensitivity for benzoylecgonine, methadone and nortriptyline (60% and 30%, 92% and 40%, and 96% and 60% sensitivity at +50% and +25% cut-off levels, respectively). The E-Z Cup exhibited lower sensitivity for oxazepam and nortriptyline (97% and 50%, and 97% and 40% sensitivity at +50% and +25% cut-off levels, respectively). We additionally evaluated test-band color by visual inspection using a standard color-scale card. When detailed color criteria for determination of positivity were applied for the E-Z Cup, using slightly less stringent criteria, oxazepam, buprenorphine, MDMA and nortriptyline showed increases in sensitivity from 70-80% to 90-100%, all with a specificity above 98%. Overall, all devices exhibited satisfactory performance at ±50% cut-off levels for commonly used drugs, with the exception of lower sensitivity for cocaine testing for DxLINK. Careful evaluation of devices and elaborate calibration of visual interpretation for determining positivity may help improve the performance of these devices. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
VMOMS — A computer code for finding moment solutions to the Grad-Shafranov equation
NASA Astrophysics Data System (ADS)
Lao, L. L.; Wieland, R. M.; Houlberg, W. A.; Hirshman, S. P.
1982-08-01
Title of program: VMOMS Catalogue number: ABSH Program obtainable from: CPC Program Library, Queen's University of Belfast, N. Ireland (See application form in this issue) Computer: PDP-10/KL10; Installation: ORNL Fusion Energy Division, Oak Ridge National Laboratory, Oak Ridge, TN 37830, USA Operating system: TOPS 10 Programming language used: FORTRAN High speed storage required: 9000 words No. of bits in a word: 36 Overlay structure: none Peripherals used: line printer, disk drive No. of cards in combined program and test deck: 2839 Card punching code: ASCII
Front-end electronics of the Belle II drift chamber
NASA Astrophysics Data System (ADS)
Shimazaki, Shoichi; Taniguchi, Takashi; Uchida, Tomohisa; Ikeno, Masahiro; Taniguchi, Nanae; Tanaka, Manobu M.
2014-01-01
This paper describes the performance of the Belle II central drift chamber (CDC) front-end electronics. The front-end electronics consists of a current sensitive preamplifier, a 1/t cancellation circuit, baseline restorers, a comparator for timing measurement and an analog buffer for the dE/dx measurement on a CDC readout card. The CDC readout card is located on the endplate of the CDC. Mass production will be completed after the performance of the chip is verified. The electrical performance and results of a neutron/gamma-ray irradiation test are reported here.
Creation of lumped parameter thermal model by the use of finite elements
NASA Technical Reports Server (NTRS)
1978-01-01
In the finite difference technique, the thermal network is represented by an analogous electrical network. The development of this network model, which is used to describe a physical system, often requires tedious and mental data preparation and checkout by the analyst which can be greatly reduced through the use of the computer programs to develop automatically the mathematical model and associated input data and graphically display the analytical model to facilitate model verification. Three separate programs are involved which are linked through common mass storage files and data card formats. These programs are SPAR, CINGEN and GEOMPLT, and are used to (1) develop thermal models for the MITAS II thermal analyzer program; (2) produce geometry plots of the thermal network; and (3) produce temperature distribution and time history plots.
Automatic computer subprogram selection from application program libraries
NASA Technical Reports Server (NTRS)
Drozdowski, J. M.
1972-01-01
The program ALTLIB (ALTernate LIBrary) which allows a user access to an alternate subprogram library with a minimum effort is discussed. The ALTLIB program selects subprograms from an alternate library file and merges them with the user's program load file. Only subprograms that are called for (directly or indirectly) by the user's programs and that are available on the alternate library file will be selected. ALTLIB eliminates the need for elaborate control-card manipulations to add subprograms from a subprogram file. ALTLIB returns to the user his binary file and the selected subprograms in correct order for a call to the loader. The user supplies the alternate library file. Subprogram requests which are not satisfied from the alternate library file will be satisfied at load time from the system library.
In vitro reconstitution of interactions in the CARD9 signalosome
Park, Jin Hee; Choi, Jae Young; Mustafa, Mir Faisal; Park, Hyun Ho
2017-01-01
The caspase-associated recruitment domain (CARD)-containing protein 9 (CARD9) signalosome is composed of CARD9, B-cell CLL/lymphoma 10 (BCL10) and mucosa-associated lymphoid tissue lymphoma translocation protein 1 (MALT1). The CARD9 signalosome has been reported to exert critical functions in the immunoreceptor tyrosine-based activation motif-coupled receptor-mediated activation of myeloid cells, through nuclear factor-κB pathways during innate immunity processes. During CARD9 signalosome assembly, BCL10 has been revealed to function as an adaptor protein and to interact with CARD9 via CARD-CARD interactions; BCL10 also interacts with MALT1 via its C-terminal Ser/Thr-rich region and the first immunoglobulin domain of MALT1. The CARD9 signalosome is implicated in critical biological processes; however, its structural and biochemical characteristics have yet to be elucidated. In the present study, CARD9 and BCL10 CARDs were successfully purified and characterized, and their biochemical properties were investigated. In addition, CARD9-BCL10 complexes were reconstituted in vitro under low salt and pH conditions. Furthermore, based on structural modeling data, a scheme was proposed to describe the interactions between CARD9 and BCL10. This provides a further understanding of the mechanism of how the CARD9 signalosome may be assembled. PMID:28765954
Biomonitoring brevetoxin exposure in mammals using blood collection cards.
Fairey, E R; Shuart, N G; Busman, M; Moeller, P D; Ramsdell, J S
2001-01-01
A method has been tested in laboratory mice to monitor for the presence of brevetoxins in blood after exposure. The use of blood collection cards is an adaptation of a method employed for routine diagnostic and genetic testing of newborns. Blood is collected and applied to a 0.5-inch diameter circle on a specially prepared blood collection card and allowed to dry. The blood spots are then extracted and the presence of toxin activity is first screened using a high throughput receptor binding assay. Positive samples are then examined for specific brevetoxin congeners by liquid chromatography-tandem mass spectrometry. Preliminary experiments tested the efficiency and linearity of toxin extraction from blood spiked with brevetoxin-3 (PbTx-3). Blood from treated mice was tested for the presence of brevetoxin at different times following exposure to a sublethal dose (180 microg/kg PbTx-3). Brevetoxin activity determined by receptor assay increased to 25 +/- 7.4 nM PbTx-3 equivalents within 4 hr after exposure and was still detectable in three of four animals 24 hr after exposure. Tandem mass spectrometry provided confirmation of PbTx-3, which also increased for the time points between 0.5 and 4.0 hr exposure. However, PbTx-3 was not detected at 24 hr, which suggested the formation of a biologically active metabolite. We anticipate that this approach will provide a method to biomonitor brevetoxins in living marine resources (e.g., finfish), protected species, and humans. PMID:11485871
A closed-loop automatic control system for high-intensity acoustic test systems.
NASA Technical Reports Server (NTRS)
Slusser, R. A.
1973-01-01
Sound at sound pressure levels in the range from 130 to 160 dB is used in the investigation. Random noise is passed through a series of parallel filters, generally 1/3-octave wide. A basic automatic system is investigated because of preadjustment inaccuracies and high costs found in a study of a typical manually controlled acoustic testing system. The unit described has been successfully used in automatic acoustic tests in connection with the spacecraft tests for the Mariner 1971 program.
ERIC Educational Resources Information Center
Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.
The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…
Imaging standards for smart cards
NASA Astrophysics Data System (ADS)
Ellson, Richard N.; Ray, Lawrence A.
1996-02-01
"Smart cards" are plastic cards the size of credit cards which contain integrated circuits for the storage of digital information. The applications of these cards for image storage has been growing as card data capacities have moved from tens of bytes to thousands of bytes. This has prompted the recommendation of standards by the X3B10 committee of ANSI for inclusion in ISO standards for card image storage of a variety of image data types including digitized signatures and color portrait images. This paper will review imaging requirements of the smart card industry, challenges of image storage for small memory devices, card image communications, and the present status of standards. The paper will conclude with recommendations for the evolution of smart card image standards towards image formats customized to the image content and more optimized for smart card memory constraints.
Imaging standards for smart cards
NASA Astrophysics Data System (ADS)
Ellson, Richard N.; Ray, Lawrence A.
1996-01-01
'Smart cards' are plastic cards the size of credit cards which contain integrated circuits for the storage of digital information. The applications of these cards for image storage has been growing as card data capacities have moved from tens of bytes to thousands of bytes. This has prompted the recommendation of standards by the X3B10 committee of ANSI for inclusion in ISO standards for card image storage of a variety of image data types including digitized signatures and color portrait images. This paper reviews imaging requirements of the smart card industry, challenges of image storage for small memory devices, card image communications, and the present status of standards. The paper concludes with recommendations for the evolution of smart card image standards towards image formats customized to the image content and more optimized for smart card memory constraints.
NASA Astrophysics Data System (ADS)
Sanchez-Romero, Alejandro; González, Josep-Abel; Calbó, Josep; Sanchez-Lorenzo, Arturo
2014-05-01
The World Meteorological Organization defines the sunshine duration (SD) as the time that, along a given period, direct solar irradiance (DSI) exceeds the threshold level of 120 W/m2. Since the end of 19th century, the Campbell-Stokes sunshine recorder (CSSR) has been the most commonly used instrument used for measuring SD. Due to the large number of long records that exist worldwide, valuable climatic information can be extracted from them. Many authors have used the daily SD (as obtained from the measurement of the length of burn for a given card) to obtain additional information about solar radiation, by using Ångström-Prescott type formulas. Contrarily, the burn width has not been systematically used. Theoretically, the burn is wider (narrower) when the direct insolation is stronger (weaker). The aim of this research is to show the relationship between burn width and DSI, and to prove whether this relationship depends on the type of CSSR and burning card. The research has been carried out in Girona (NE Spain) for a period of two years (from January 2012 to January 2014). Two different models of CSSR (which use different types of cards) and a pyrheliometer from Kipp&Zonen were used to measure SD and DSI, respectively. A semi-automatic method based on image processing of digital scanned images of burnt cards is presented. The method can be summarized in four steps: (i) scan each band on a green background; (ii) apply a digital process to increase the contrast of the burn; (iii) define two/three points in the image, depending of the geometry of the card, to point the center of the day (12.00 TST) on the image and define the trajectory of the sun with 1-minute intervals; and (iv) apply a program to make cross-sections every minute and measure the width of burn. So, after all of this process, we obtain a temporal evolution of the burn width with 1-minute resolution and distinguishing between morning and afternoon. The results show that there is a good correlation between the burn widths obtained from the two types of CSSR. We also observe a quite good correlation with DSI, which is consistent with our hypothesis. However, if we study the threshold value, we obtain a wide range of values that are almost always higher than 120 W/m2, with a significant difference between the morning and afternoon records. Consequently, we consider that the behaviour of cards may also depend on other meteorological variables (temperature, humidity…) affecting the burn. The physical characteristics of the heliograph and of the cardboard from which the bands are made may also have an important role in this relationship. The method was applied to a limited series of cards, but could offer a practical way to exploit the worldwide sets of long-term CSSR data to create long time series of DSI. As there are methods to extract atmospheric aerosol content based on DSI (Linke turbidity factor, Ångström's turbidity coefficient, etc.), SD may become a proxy measurement for turbidity and atmospheric aerosol loading since the late 19th century.
Melanson, Vanessa R; Jochim, Ryan; Yarnell, Michael; Ferlez, Karen Bingham; Shashikumar, Soumya; Richardson, Jason H
2017-01-01
Vector-borne pathogen surveillance programmes typically rely on the collection of large numbers of potential vectors followed by screening protocols focused on detecting pathogens in the arthropods. These processes are laborious, time consuming, expensive, and require screening of large numbers of samples. To streamline the surveillance process, increase sample throughput, and improve cost-effectiveness, a method to detect dengue virus and malaria parasites (Plasmodium falciparum) by leveraging the sugar-feeding behaviour of mosquitoes and their habit of expectorating infectious agents in their saliva during feeding was investigated in this study. Dengue virus 2 (DENV-2) infected female Aedes aegypti mosquitoes and P. falciparum infected female Anopheles stephensi mosquitoes were allowed to feed on honey coated Flinders Technical Associates -FTA® cards dyed with blue food colouring. The feeding resulted in deposition of saliva containing either DENV-2 particles or P. falciparum sporozoites onto the FTA card. Nucleic acid was extracted from each card and the appropriate real-time PCR (qPCR) assay was run to detect the pathogen of interest. As little as one plaque forming unit (PFU) of DENV-2 and as few as 60 P. falciparum parasites deposited on FTA cards from infected mosquitoes were detected via qPCR. Hence, their use to collect mosquito saliva for pathogen detection is a relevant technique for vector surveillance. This study provides laboratory confirmation that FTA cards can be used to capture and stabilize expectorated DENV-2 particles and P. falciparum sporozoites from infectious, sugar-feeding mosquitoes in very low numbers. Thus, the FTA card-based mosquito saliva capture method offers promise to overcome current limitations and revolutionize traditional mosquito-based pathogen surveillance programmes. Field testing and further method development are required to optimize this strategy.
Araujo, Ana Carla Pereira de; Santos, Bruno F de Oliveira; Calasans, Flavia Ricci; Pinto, Ibraim M Francisco; Oliveira, Daniel Pio de; Melo, Luiza Dantas; Andrade, Stephanie Macedo; Tavares, Irlaneide da Silva; Sousa, Antonio Carlos Sobral; Oliveira, Joselina Luzia Menezes
2014-11-01
Background: Studies have demonstrated the diagnostic accuracy and prognostic value of physical stress echocardiography in coronary artery disease. However, the prediction of mortality and major cardiac events in patients with exercise test positive for myocardial ischemia is limited. Objective: To evaluate the effectiveness of physical stress echocardiography in the prediction of mortality and major cardiac events in patients with exercise test positive for myocardial ischemia. Methods: This is a retrospective cohort in which 866 consecutive patients with exercise test positive for myocardial ischemia, and who underwent physical stress echocardiography were studied. Patients were divided into two groups: with physical stress echocardiography negative (G1) or positive (G2) for myocardial ischemia. The endpoints analyzed were all-cause mortality and major cardiac events, defined as cardiac death and non-fatal acute myocardial infarction. Results: G2 comprised 205 patients (23.7%). During the mean 85.6 ± 15.0-month follow-up, there were 26 deaths, of which six were cardiac deaths, and 25 non-fatal myocardial infarction cases. The independent predictors of mortality were: age, diabetes mellitus, and positive physical stress echocardiography (hazard ratio: 2.69; 95% confidence interval: 1.20 - 6.01; p = 0.016). The independent predictors of major cardiac events were: age, previous coronary artery disease, positive physical stress echocardiography (hazard ratio: 2.75; 95% confidence interval: 1.15 - 6.53; p = 0.022) and absence of a 10% increase in ejection fraction. All-cause mortality and the incidence of major cardiac events were significantly higher in G2 (p < 0. 001 and p = 0.001, respectively). Conclusion: Physical stress echocardiography provides additional prognostic information in patients with exercise test positive for myocardial ischemia.Fundamento: Estudos têm demonstrado a acurácia diagnóstica e o valor prognóstico da ecocardiografia com estresse físico na doença arterial coronária, mas a predição de mortalidade e de eventos cardíacos maiores, em pacientes com teste ergométrico positivo para isquemia miocárdica, é limitada. Objetivo: Avaliar a predição de mortalidade e de eventos cardíacos maiores pela ecocardiografia com estresse físico em pacientes com teste ergométrico positivo para isquemia miocárdica. Métodos: Trata-se de uma coorte retrospectiva em que foram estudados 866 pacientes consecutivos, com teste ergométrico positivo para isquemia miocárdica, submetidos à ecocardiografia com estresse físico. Os pacientes foram divididos em dois grupos: ecocardiografia com estresse físico negativa (G1) ou positiva (G2) para isquemia miocárdica. Os desfechos avaliados foram mortalidade por qualquer causa e eventos cardíacos maiores, definidos como óbito cardíaco e infarto agudo do miocárdio não fatal. Resultados: O G2 constituiu-se de 205 (23,7%) pacientes. Durante o seguimento médio de 85,6 ± 15,0 meses, ocorreram 26 óbitos, sendo seis por causa cardíaca, e 25 casos de infarto agudo do miocárdio não fatais. Os preditores independentes de mortalidade foram idade, diabetes melito e a ecocardiografia com estresse físico + (hazard ratio: 2,69; intervalo de confiança de 95%: 1,20 - 6,01; p = 0,016), com os seguintes eventos cardíacos maiores: idade, doença arterial coronária prévia, ecocardiografia com estresse físico + (hazard ratio: 2,75; intervalo de confiança de 95%: 1,15 - 6,53; p = 0,022) e ausência do incremento de 10% na fração de ejeção. A mortalidade por qualquer causa e os eventos cardíacos maiores foram significativamente superiores no G2 (p < 0, 001 e p = 0,001, respectivamente). Conclusão: A ecocardiografia com estresse físico oferece informações prognósticas adicionais em pacientes com teste ergométrico positivo para isquemia miocárdica.
36 CFR 1254.84 - How may I use a debit card for copiers in the Washington, DC, area?
Code of Federal Regulations, 2010 CFR
2010-07-01
..., money order, debit card, or credit card. Your researcher identification card number as encoded on the... 1253 of this chapter, you may use cash or credit card to purchase a debit card from the vending... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false How may I use a debit card...
Wadlin, Jill K.; Hanko, Gayle; Stewart, Rebecca; Pape, John; Nachamkin, Irving
1999-01-01
We evaluated three commercial systems (RapID Yeast Plus System; Innovative Diagnostic Systems, Norcross, Ga.; API 20C Aux; bioMerieux-Vitek, Hazelwood, Mo.; and Vitek Yeast Biochemical Card, bioMerieux-Vitek) against an auxinographic and microscopic morphologic reference method for the ability to identify yeasts commonly isolated in our clinical microbiology laboratory. Two-hundred one yeast isolates were compared in the study. The RapID Yeast Plus System was significantly better than either API 20C Aux (193 versus 167 correct identifications; P < 0.0001) or the Vitek Yeast Biochemical Card (193 versus 173 correct identifications; P = 0.003) for obtaining correct identifications to the species level without additional testing. There was no significant difference between results obtained with API 20C Aux and the Vitek Yeast Biochemical Card system (P = 0.39). The API 20C Aux system did not correctly identify any of the Candida krusei isolates (n = 23) without supplemental testing and accounted for the major differences between the API 20C Aux and RapID Yeast Plus systems. Overall, the RapID Yeast Plus System was easy to use and is a good system for the routine identification of clinically relevant yeasts. PMID:10325356
Dynamic Virtual Credit Card Numbers
NASA Astrophysics Data System (ADS)
Molloy, Ian; Li, Jiangtao; Li, Ninghui
Theft of stored credit card information is an increasing threat to e-commerce. We propose a dynamic virtual credit card number scheme that reduces the damage caused by stolen credit card numbers. A user can use an existing credit card account to generate multiple virtual credit card numbers that are either usable for a single transaction or are tied with a particular merchant. We call the scheme dynamic because the virtual credit card numbers can be generated without online contact with the credit card issuers. These numbers can be processed without changing any of the infrastructure currently in place; the only changes will be at the end points, namely, the card users and the card issuers. We analyze the security requirements for dynamic virtual credit card numbers, discuss the design space, propose a scheme using HMAC, and prove its security under the assumption the underlying function is a PRF.
Test Review: Prueba del Desarrollo Inicial del Lenguaje.
ERIC Educational Resources Information Center
Crawford, Alan N.
1985-01-01
Concludes that the PDIL (the Spanish version of the Test of Early Language Development) should be used with caution. Since its reliability and validity were determined with the English language version, the method used to translate test items may have some ambiguities, and some illustrations on picture cards may not be culturally appropriate for…
Joint Service Magazine Advertising Test. Spring 1978.
1979-04-01
This is a test of the relative efficiency and effectiveness of joint Service advertising versus solo Service advertising of the Active Services...Subtests conducted were performance of page versus spread advertisements and four box versus three-line business reply cards. Call back research was conducted to validate findings of the major test. (Author)
Next Generation Instrumentation Bus Test Plan for Fibre Channel
1999-09-30
sample for port testing. The heart of the Fibre Xpress network cards is the tachyon chip from Hewlett Packard. The tachyon chip is basically a single...be to test the protocols. 1.5.1.1 Tachyon chip The user’s manual for the Tachyon controller chip identifies the following FC-AL specification
The Debate over National Testing. ERIC Digest.
ERIC Educational Resources Information Center
Boston, Carol
This digest presents various views of the federal role in testing and offers a brief examination of the National Assessment of Educational Progress (NAEP), the "nation's report card," in its national sample format and its state administration, which critics fear has the potential to become a de facto national test if selected as the…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-08
... DEPARTMENT OF AGRICULTURE Animal and Plant Health Inspection Service [Docket No. APHIS-2011-0063] Notice of Request for Approval of an Information Collection; Brucellosis First Point Testing of Cattle and Bison; Brucellosis Standard Card Test AGENCY: Animal and Plant Health Inspection Service, USDA...
Students using mobile phones in the classroom: Can the phones increase content learning
NASA Astrophysics Data System (ADS)
Rinehart, David Lee
A study was conducted at a high-performing school in Southern California to explore the effects on learning content from students using their own smart phones in and out of the classroom. The study used a Switching Replications design format which allowed two independent analyses of posttest scores between a group using e-flash cards on smart phones and a group using paper flash cards. Quantitative data was collected via two tailed, t-tests and qualitative data was collected through observations and interviews. Results suggest that knowledge level learning may be increased with mobile phone use, but no effect on comprehension level learning was found. Students found the phones to be convenient in accessing flash cards anytime and anywhere. Enthusiasm for using the phones in class while initially high waned over the 1 month study duration. Students perceived the phones to not be a significant source of distraction outside of class.
SAE for the prediction of road traffic status from taxicab operating data and bus smart card data
NASA Astrophysics Data System (ADS)
Zhengfeng, Huang; Pengjun, Zheng; Wenjun, Xu; Gang, Ren
Road traffic status is significant for trip decision and traffic management, and thus should be predicted accurately. A contribution is that we consider multi-modal data for traffic status prediction than only using single source data. With the substantial data from Ningbo Passenger Transport Management Sector (NPTMS), we wished to determine whether it was possible to develop Stacked Autoencoders (SAEs) for accurately predicting road traffic status from taxicab operating data and bus smart card data. We show that SAE performed better than linear regression model and Back Propagation (BP) neural network for determining the relationship between road traffic status and those factors. In a 26-month data experiment using SAE, we show that it is possible to develop highly accurate predictions (91% test accuracy) of road traffic status from daily taxicab operating data and bus smart card data.
Development of multichannel analyzer using sound card ADC for nuclear spectroscopy system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ibrahim, Maslina Mohd; Yussup, Nolida; Lombigit, Lojius
This paper describes the development of Multi-Channel Analyzer (MCA) using sound card analogue to digital converter (ADC) for nuclear spectroscopy system. The system was divided into a hardware module and a software module. Hardware module consist of detector NaI (Tl) 2” by 2”, Pulse Shaping Amplifier (PSA) and a build in ADC chip from readily available in any computers’ sound system. The software module is divided into two parts which are a pre-processing of raw digital input and the development of the MCA software. Band-pass filter and baseline stabilization and correction were implemented for the pre-processing. For the MCA development,more » the pulse height analysis method was used to process the signal before displaying it using histogram technique. The development and tested result for using the sound card as an MCA are discussed.« less
Cuvo, A J; Klatt, K P
1992-01-01
Community-referenced sight words and phrases were taught to adolescents with mild and moderate mental retardation using three instructional methods in two locations. Words were presented on flash cards in a school setting, on videotape recordings in a school setting, and on naturally occurring signs in the community. During each session, participants were taught one third of the words in each of these conditions and were then tested at the community sites. A constant prompt delay procedure was used to promote stimulus control to the experimenter's cue initially and then to transfer control to the textual stimuli used for training. A multiple baseline across participants design was employed. Results showed rapid acquisition of the community-referenced sight words in all three training conditions and generalization from the flash card and videotape conditions to the community sites. PMID:1378827
[Automatic adjustment control system for DC glow discharge plasma source].
Wan, Zhen-zhen; Wang, Yong-qing; Li, Xiao-jia; Wang, Hai-zhou; Shi, Ning
2011-03-01
There are three important parameters in the DC glow discharge process, the discharge current, discharge voltage and argon pressure in discharge source. These parameters influence each other during glow discharge process. This paper presents an automatic control system for DC glow discharge plasma source. This system collects and controls discharge voltage automatically by adjusting discharge source pressure while the discharge current is constant in the glow discharge process. The design concept, circuit principle and control program of this automatic control system are described. The accuracy is improved by this automatic control system with the method of reducing the complex operations and manual control errors. This system enhances the control accuracy of glow discharge voltage, and reduces the time to reach discharge voltage stability. The glow discharge voltage stability test results with automatic control system are provided as well, the accuracy with automatic control system is better than 1% FS which is improved from 4% FS by manual control. Time to reach discharge voltage stability has been shortened to within 30 s by automatic control from more than 90 s by manual control. Standard samples like middle-low alloy steel and tin bronze have been tested by this automatic control system. The concentration analysis precision has been significantly improved. The RSDs of all the test result are better than 3.5%. In middle-low alloy steel standard sample, the RSD range of concentration test result of Ti, Co and Mn elements is reduced from 3.0%-4.3% by manual control to 1.7%-2.4% by automatic control, and that for S and Mo is also reduced from 5.2%-5.9% to 3.3%-3.5%. In tin bronze standard sample, the RSD range of Sn, Zn and Al elements is reduced from 2.6%-4.4% to 1.0%-2.4%, and that for Si, Ni and Fe is reduced from 6.6%-13.9% to 2.6%-3.5%. The test data is also shown in this paper.
NASA Astrophysics Data System (ADS)
Ratnadewi; Pramono Adhie, Roy; Hutama, Yonatan; Saleh Ahmar, A.; Setiawan, M. I.
2018-01-01
Cryptography is a method used to create secure communication by manipulating sent messages during the communication occurred so only intended party that can know the content of that messages. Some of the most commonly used cryptography methods to protect sent messages, especially in the form of text, are DES and 3DES cryptography method. This research will explain the DES and 3DES cryptography method and its use for stored data security in smart cards that working in the NFC-based communication system. Several things that will be explained in this research is the ways of working of DES and 3DES cryptography method in doing the protection process of a data and software engineering through the creation of application using C++ programming language to realize and test the performance of DES and 3DES cryptography method in encrypted data writing process to smart cards and decrypted data reading process from smart cards. The execution time of the entering and the reading process data using a smart card DES cryptography method is faster than using 3DES cryptography.
Health communication cards as a tool for behaviour change.
Matteson, Carrie L; Merth, Thomas D N; Finegood, Diane T
2014-01-01
Individuals seeking healthcare treatment in the context of obesity often experience difficulty engaging in discussions around their health and face challenges finding consensus with practitioners on care plans that best suit their lives. The complex set of biological, social, and environmental variables that have contributed to the higher prevalence of obesity are well illustrated in the foresight obesity system map. Effectively understanding and addressing key variables for each individual has proven to be difficult, with clinicians facing barriers and limited resources to help address patients' unique needs. However, productive discussions inspired by patient centered care may be particularly effective in promoting behaviour change. Tools based on systems science that facilitate patient centered care and help identify behaviour change priorities have not been developed to help treat adult obesity. This project created and pilot tested a card based clinical communication tool designed to help facilitate conversations with individuals engaged in health behaviour change. The health communication cards were designed to help direct conversation between patients and healthcare providers toward issues relevant to the individual. Use of the cards to facilitate patient driven conversations in clinical care may help to streamline conversations, set realistic care plan goals, and improve long term rates of compliance.
Guio, H; Okayama, H; Ashino, Y; Saitoh, H; Xiao, P; Miki, M; Yoshihara, N; Nakanowatari, S; Hattori, T
2006-08-01
The polymerase chain reaction (PCR) is a highly sensitive method for the detection of Mycobacterium tuberculosis and is available in most countries, though to a lesser extent in rural areas. To amplify M. tuberculosis DNA sequences of sputum spotted on FTA cards and compare them with the results of microscopic examination among culture-positive samples. A total of 102 sputum specimens of TB patients in treatment were spotted on FTA cards and stored at room temperature until DNA analysis. We assessed the IS6110 region of M. tuberculosis. The efficacy of the PCR assay for the direct detection of M. tuberculosis was evaluated and compared with the results of cultures (Middlebrook 7H9 broth) and smears of fresh sputum specimens. We were able to detect 10 fg/microl of mycobacterial DNA even after 6 months in storage. The PCR sensitivity and specificity using the FTA card system were 82% and 96%, while microscopic examination showed 41% and 95%, respectively. The FTA card system for the storage of bacterial DNA from sputum samples should be considered for the molecular diagnosis of tuberculosis. Samples can easily be obtained from geographically isolated populations and shipped by mail for accurate molecular diagnosis.
Development of the biology card sorting task to measure conceptual expertise in biology.
Smith, Julia I; Combs, Elijah D; Nagami, Paul H; Alto, Valerie M; Goh, Henry G; Gourdet, Muryam A A; Hough, Christina M; Nickell, Ashley E; Peer, Adrian G; Coley, John D; Tanner, Kimberly D
2013-01-01
There are widespread aspirations to focus undergraduate biology education on teaching students to think conceptually like biologists; however, there is a dearth of assessment tools designed to measure progress from novice to expert biological conceptual thinking. We present the development of a novel assessment tool, the Biology Card Sorting Task, designed to probe how individuals organize their conceptual knowledge of biology. While modeled on tasks from cognitive psychology, this task is unique in its design to test two hypothesized conceptual frameworks for the organization of biological knowledge: 1) a surface feature organization focused on organism type and 2) a deep feature organization focused on fundamental biological concepts. In this initial investigation of the Biology Card Sorting Task, each of six analytical measures showed statistically significant differences when used to compare the card sorting results of putative biological experts (biology faculty) and novices (non-biology major undergraduates). Consistently, biology faculty appeared to sort based on hypothesized deep features, while non-biology majors appeared to sort based on either surface features or nonhypothesized organizational frameworks. Results suggest that this novel task is robust in distinguishing populations of biology experts and biology novices and may be an adaptable tool for tracking emerging biology conceptual expertise.
Werner, Rachel M; Konetzka, R Tamara; Polsky, Daniel
2016-06-01
Limited consumer use of health care report cards may be due to the large amount of information presented in report cards, which can be difficult to understand. These limitations may be overcome with summary measures. Our objective was to evaluate consumer response to summary measures in the setting of nursing homes. 2005-2010 nursing home Minimum Data Set and Online Survey, Certification and Reporting (OSCAR) datasets. In December 2008, Medicare converted its nursing home report card to summary or star ratings. We test whether there was a change in consumer demand for nursing homes related to the nursing home's star rating after the information was released. The star rating system was associated with a significant change in consumer demand for low- and high-scoring facilities. After the star-based rating system was released, 1-star facilities typically lost 8 percent of their market share and 5-star facilities gained over 6 percent of their market share. The nursing home star rating system significantly affected consumer demand for high- and low-rated nursing homes. These results support the use of summary measures in report cards. © Health Research and Educational Trust.
75 FR 70753 - Market Test Involving Greeting Cards
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-18
... businesses will produce and distribute pre-approved envelopes according to specific design requirements which... will produce and distribute pre-approved envelopes with specific design requirements that will be... a market test beginning on or about January 1, 2011, of an experimental market dominant product...
Zhang, Haiyan; Wen, Shenglin; Wang, Jihui; Cheng, Minfeng; Wang, Hong
2015-03-10
To explore the magnetic resonance spectroscopy characteristics of lenticular nucleus in Bipolar II disorder and its relation with cognitive function. Thirty Bipolar II disorder patients in hospital from 2012 September to 2013 April and twenty healthy controls were evaluated with Multi-Voxel 1H-MRS scans on lenticular nucleus to assess the NAA, Cho, Cr and MI. All subjects were assessed for attention using the Stroop Test and executive function by Wisconsin card sorting test. NAA, Cho, Cr in right lenticular nucleus and Cr in left lenticular nucleus were lower than healthy controls (P < 0.05). The patients showed significant cognitive impairment in all aspects of Stroop Test and Wisconsin card sorting test (P < 0.05). NAA in right lenticular nucleus was positively correlated with correct number of Stroop-CW. Neural dysfunction in right lenticular nucleus of Bipolar II disorder may influence attention function. Cellular energy metabolism rate was reduced in bilateral lenticular nucleus.
Citizen empowerment using healthcare and welfare cards.
Cheshire, Paul
2006-01-01
Cards are used in health and welfare to establish the identity of the person presenting the card; to prove their entitlement to a welfare or healthcare service; to store data needed within the care process; and to store data to use in the administration process. There is a desire to empower citizens - to give them greater control over their lives, their health and wellbeing. How can a healthcare and welfare card support this aim? Does having a card empower the citizen? What can a citizen do more easily, reliably, securely or cost-effectively because they have a card? A number of possibilities include: Choice of service provider; Mobility across regional and national boundaries; Privacy; and Anonymity. But in all of these possibilities a card is just one component of a total system and process, and there may be other solutions--technological and manual. There are risks and problems from relying on a card; and issues of Inclusion for people who are unable use a card. The article concludes that: cards need to be viewed in the context of the whole solution; cards are not the only technological mechanism; cards are not the best mechanism in all circumstances; but cards are very convenient method in very many situations.
Performance of patients with schizophrenia on the Wisconsin Card Sorting Test (WCST).
Everett, J; Lavoie, K; Gagnon, J F; Gosselin, N
2001-03-01
To directly compare the performance of patients with schizophrenia and control subjects on the Wisconsin Card Sorting Test (WCST). Specifically, we sought to verify if there are significant differences on the "classical" WCST measurements (perseverative errors and number of categories), as well as on more rarely reported scores, and assess the extent to which patients with schizophrenia can improve their performance with card-by-card instructions and continuous verbal reinforcement. Prospective cross-sectional study. Psychiatry department in a university-affiliated hospital. 30 patients with schizophrenia, diagnosed according to DSM-IV criteria, and 30 control subjects, matched to patients according to age and education. The WCST was administered according to the criteria of Heaton, and a subgroup of the patients with schizophrenia was given a retest after an explanation of the WCST and verbal reinforcements. Patients with schizophrenia succeeded on fewer categories (t = 23.3, p < 0.001), committed more perseverative errors (t = 15.6, p < 0.001), made more perseverative responses (t = 14.6, p < 0.001), needed more trials to succeed at the first category (t = 9.2, p < 0.003) and gave significantly lower conceptual level responses (t = 14.1, p < 0.001) than the controls. However, on retest, patients with schizophrenia committed significantly fewer perseverative errors (t = 5.1, p < 0.001) and showed higher conceptual level responses (t = -3.45, p < 0.003). Consistent with a hypothesis of frontal dysfunction in schizophrenia, patients with schizophrenia tend to show a perseverative deficit; however, some are able to partially overcome this deficit when given verbal reinforcement.
Performance of patients with schizophrenia on the Wisconsin Card Sorting Test (WCST).
Everett, J; Lavoie, K; Gagnon, J F; Gosselin, N
2001-01-01
OBJECTIVE: To directly compare the performance of patients with schizophrenia and control subjects on the Wisconsin Card Sorting Test (WCST). Specifically, we sought to verify if there are significant differences on the "classical" WCST measurements (perseverative errors and number of categories), as well as on more rarely reported scores, and assess the extent to which patients with schizophrenia can improve their performance with card-by-card instructions and continuous verbal reinforcement. DESIGN: Prospective cross-sectional study. SETTING: Psychiatry department in a university-affiliated hospital. PARTICIPANTS: 30 patients with schizophrenia, diagnosed according to DSM-IV criteria, and 30 control subjects, matched to patients according to age and education. INTERVENTION: The WCST was administered according to the criteria of Heaton, and a subgroup of the patients with schizophrenia was given a retest after an explanation of the WCST and verbal reinforcements. RESULTS: Patients with schizophrenia succeeded on fewer categories (t = 23.3, p < 0.001), committed more perseverative errors (t = 15.6, p < 0.001), made more perseverative responses (t = 14.6, p < 0.001), needed more trials to succeed at the first category (t = 9.2, p < 0.003) and gave significantly lower conceptual level responses (t = 14.1, p < 0.001) than the controls. However, on retest, patients with schizophrenia committed significantly fewer perseverative errors (t = 5.1, p < 0.001) and showed higher conceptual level responses (t = -3.45, p < 0.003). CONCLUSION: Consistent with a hypothesis of frontal dysfunction in schizophrenia, patients with schizophrenia tend to show a perseverative deficit; however, some are able to partially overcome this deficit when given verbal reinforcement. PMID:11291529
Nowinski, Wieslaw L; Thirunavuukarasuu, Arumugam; Ananthasubramaniam, Anand; Chua, Beng Choon; Qian, Guoyu; Nowinska, Natalia G; Marchenko, Yevgen; Volkau, Ihar
2009-10-01
Preparation of tests and student's assessment by the instructor are time consuming. We address these two tasks in neuroanatomy education by employing a digital media application with a three-dimensional (3D), interactive, fully segmented, and labeled brain atlas. The anatomical and vascular models in the atlas are linked to Terminologia Anatomica. Because the cerebral models are fully segmented and labeled, our approach enables automatic and random atlas-derived generation of questions to test location and naming of cerebral structures. This is done in four steps: test individualization by the instructor, test taking by the students at their convenience, automatic student assessment by the application, and communication of the individual assessment to the instructor. A computer-based application with an interactive 3D atlas and a preliminary mobile-based application were developed to realize this approach. The application works in two test modes: instructor and student. In the instructor mode, the instructor customizes the test by setting the scope of testing and student performance criteria, which takes a few seconds. In the student mode, the student is tested and automatically assessed. Self-testing is also feasible at any time and pace. Our approach is automatic both with respect to test generation and student assessment. It is also objective, rapid, and customizable. We believe that this approach is novel from computer-based, mobile-based, and atlas-assisted standpoints.
Aubertine, C. L.; Rivera, M.; Rohan, S. M.; Larone, D. H.
2006-01-01
The new VITEK 2 colorimetric card was compared to the previous fluorometric card for identification of yeast. API 20C was considered the “gold standard.” The new card consistently performed better than the older card. Isolates from CHROMagar Candida plates were identified equally as well as those from Sabouraud dextrose agar. PMID:16390976
A microprocessor card software server to support the Quebec health microprocessor card project.
Durant, P; Bérubé, J; Lavoie, G; Gamache, A; Ardouin, P; Papillon, M J; Fortin, J P
1995-01-01
The Quebec Health Smart Card Project is advocating the use of a memory card software server[1] (SCAM) to implement a portable medical record (PMR) on a smart card. The PMR is viewed as an object that can be manipulated by SCAM's services. In fact, we can talk about a pseudo-object-oriented approach. This software architecture provides a flexible and evolutive way to manage and optimize the PMR. SCAM is a generic software server; it can manage smart cards as well as optical (laser) cards or other types of memory cards. But, in the specific case of the Quebec Health Card Project, SCAM is used to provide services between physicians' or pharmacists' software and IBM smart card technology. We propose to expose the concepts and techniques used to provide a generic environment to deal with smart cards (and more generally with memory cards), to obtain a dynamic an evolutive PMR, to raise the system global security level and the data integrity, to optimize significantly the management of the PMR, and to provide statistic information about the use of the PMR.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Avramova, Maria; Toptan, Aysenur; Porter, Nathan
This document describes how to make a CTF input deck. A CTF input deck is organized into Card Groups and Cards. A Card Group is a collection of Cards. A Card is de ned as a line of input. Each Card may contain multiple data. A Card is terminated by making a new line. This document has been organized so that each Card Group is discussed in its own dedicated chapter. Each card is discused in its own dedicated section. Each data in the card is discussed in its own block. The block gives information about the data, including themore » number of the input, the title, a description of the meaning of the data, units, data type, and so on. An example block is shown below to discuss the meaning of each entry in the block.« less
[Micron]ADS-B Detect and Avoid Flight Tests on Phantom 4 Unmanned Aircraft System
NASA Technical Reports Server (NTRS)
Arteaga, Ricardo; Dandachy, Mike; Truong, Hong; Aruljothi, Arun; Vedantam, Mihir; Epperson, Kraettli; McCartney, Reed
2018-01-01
Researchers at the National Aeronautics and Space Administration Armstrong Flight Research Center in Edwards, California and Vigilant Aerospace Systems collaborated for the flight-test demonstration of an Automatic Dependent Surveillance-Broadcast based collision avoidance technology on a small unmanned aircraft system equipped with the uAvionix Automatic Dependent Surveillance-Broadcast transponder. The purpose of the testing was to demonstrate that National Aeronautics and Space Administration / Vigilant software and algorithms, commercialized as the FlightHorizon UAS"TM", are compatible with uAvionix hardware systems and the DJI Phantom 4 small unmanned aircraft system. The testing and demonstrations were necessary for both parties to further develop and certify the technology in three key areas: flights beyond visual line of sight, collision avoidance, and autonomous operations. The National Aeronautics and Space Administration and Vigilant Aerospace Systems have developed and successfully flight-tested an Automatic Dependent Surveillance-Broadcast Detect and Avoid system on the Phantom 4 small unmanned aircraft system. The Automatic Dependent Surveillance-Broadcast Detect and Avoid system architecture is especially suited for small unmanned aircraft systems because it integrates: 1) miniaturized Automatic Dependent Surveillance-Broadcast hardware; 2) radio data-link communications; 3) software algorithms for real-time Automatic Dependent Surveillance-Broadcast data integration, conflict detection, and alerting; and 4) a synthetic vision display using a fully-integrated National Aeronautics and Space Administration geobrowser for three dimensional graphical representations for ownship and air traffic situational awareness. The flight-test objectives were to evaluate the performance of Automatic Dependent Surveillance-Broadcast Detect and Avoid collision avoidance technology as installed on two small unmanned aircraft systems. In December 2016, four flight tests were conducted at Edwards Air Force Base. Researchers in the ground control station looking at displays were able to verify the Automatic Dependent Surveillance-Broadcast target detection and collision avoidance resolutions.
Pizzuti, A; Baralis, G; Bassignana, A; Antonielli, E; Di Leo, M
1997-01-01
The MS200 Cardioscope, from MRT Micro as., Norway, is a 12 channel ECG card to be directly inserted into a standard personal computer (PC). The standard ISA Bus compatible half length card comes with a set of 10 cables with electrodes and the software for recording, displaying and saving ECG signals. The system is supplied with DOS or Windows software. The goal of the present work was to evaluate the affordability and usability of the MS200 in a clinical setting. We tested the 1.5 DOS version of the software. In 30 patients with various cardiac diseases the ECG signal has been recorded with MS200 and with standard Hellige CardioSmart equipment. The saved ECGs were recalled and printed using an Epson Stylus 800 ink-jet printer. Two cardiologists reviewed the recordings for a looking at output quality, amplitude and speed precision, artifacts, etc. 1) Installation: the card has proven to be totally compatible with the hardware; no changes in default settings had to be made. 2) Usage: the screens are clear; the commands and menus are intuitive and easy to use. Due to the boot-strap and software loading procedures and, most important, off-line printing, the time needed to obtain a complete ECG printout has been longer than that of the reference machine. 3) Archiving and retrieval of ECG: the ECG curves can be saved in original or compressed form: selecting the latter, the noise and non-ECG information is filtered away and the space consumption on disk is reduced: on average, 20 Kb are needed for 10 seconds of signal. The MS200 can be run on a Local Area Network and is prepared for integrating with an existing informative system: we are currently testing the system in this scenery. 4) MS200 includes options for on-line diagnosis, a technology we have not tested in the present work. 5) The only setting allowed for printing full pages is letter size (A4): the quality of printouts is good, with a resolution of 180 DPI. In conclusion, the MS200 system seems reliable and safe. In the configuration we tested, it cannot substitute a dedicated ECG equipment: from this point of view, a smaller PCMCIA-type card with a battery-operated notebook PC will be more suitable for clinical uses. Nevertheless, the possibility to log and track ECG records, integrated into the department informative system, may provide a valuable tool for improving access to medical information.
Patients' Awareness, Usage and Impact of Hospital Report Cards in the US.
Emmert, Martin; Schlesinger, Mark
2017-12-01
Little knowledge is available about the importance of hospital report cards in the US from the patients' perspective. It also remains unknown whether specific report cards with a stronger emphasis on clinical measures have a greater impact on hospital choice than general report cards that focus on online-derived ratings. The aim of this study was to determine the awareness and usage of hospital report cards as well as their impact on hospital choice in the US. We conducted a cross-sectional study by surveying a stratified online sample (N = 1332) to ensure representativeness to the US online population (February 2015). Overall, 75% of all respondents (mean age 45.4 years; 54% female) were aware of hospital report cards. Among these, 56% had used a report card to search for a hospital, and 80% of report card users stated having been influenced by a report card. Both the awareness and usage of general report cards were shown to be higher than for specific report cards. No significant differences could be detected regarding the impact between general or specific report cards on hospital choice. Our results indicate that hospital report cards play a considerable role among patients when searching for a hospital in the US; however, patients do not seem to have a preference regarding the type of report cards they use when selecting a hospital.
Saieg, Mauro Ajaj; Geddie, William R; Boerner, Scott L; Liu, Ni; Tsao, Ming; Zhang, Tong; Kamel-Reid, Suzanne; da Cunha Santos, Gilda
2012-06-25
Novel high-throughput molecular technologies have made the collection and storage of cells and small tissue specimens a critical issue. The FTA card provides an alternative to cryopreservation for biobanking fresh unfixed cells. The current study compared the quality and integrity of the DNA obtained from 2 types of FTA cards (Classic and Elute) using 2 different extraction protocols ("Classic" and "Elute") and assessed the feasibility of performing multiplex mutational screening using fine-needle aspiration (FNA) biopsy samples. Residual material from 42 FNA biopsies was collected in the cards (21 Classic and 21 Elute cards). DNA was extracted using the Classic protocol for Classic cards and both protocols for Elute cards. Polymerase chain reaction for p53 (1.5 kilobase) and CARD11 (500 base pair) was performed to assess DNA integrity. Successful p53 amplification was achieved in 95.2% of the samples from the Classic cards and in 80.9% of the samples from the Elute cards using the Classic protocol and 28.5% using the Elute protocol (P = .001). All samples (both cards) could be amplified for CARD11. There was no significant difference in the DNA concentration or 260/280 purity ratio when the 2 types of cards were compared. Five samples were also successfully analyzed by multiplex MassARRAY spectrometry, with a mutation in KRAS found in 1 case. High molecular weight DNA was extracted from the cards in sufficient amounts and quality to perform high-throughput multiplex mutation assays. The results of the current study also suggest that FTA Classic cards preserve better DNA integrity for molecular applications compared with the FTA Elute cards. Copyright © 2012 American Cancer Society.
Constraints to estimating the prevalence of trypanosome infections in East African zebu cattle.
Cox, Andrew P; Tosas, Olga; Tilley, Aimee; Picozzi, Kim; Coleman, Paul; Hide, Geoff; Welburn, Susan C
2010-09-06
In East Africa, animal trypanosomiasis is caused by many tsetse transmitted protozoan parasites including Trypanosoma vivax, T. congolense and subspecies of T. brucei s.l. (T. b. brucei and zoonotic human infective T. b. rhodesiense) that may co-circulate in domestic and wild animals. Accurate species-specific prevalence measurements of these parasites in animal populations are complicated by mixed infections of trypanosomes within individual hosts, low parasite densities and difficulties in conducting field studies. Many Polymerase Chain Reaction (PCR) based diagnostic tools are available to characterise and quantify infection in animals. These are important for assessing the contribution of infections in animal reservoirs and the risk posed to humans from zoonotic trypanosome species. New matrices for DNA capture have simplified large scale field PCR analyses but few studies have examined the impact of these techniques on prevalence estimations. The Whatman FTA matrix has been evaluated using a random sample of 35 village zebu cattle from a population naturally exposed to trypanosome infection. Using a generic trypanosome-specific PCR, prevalence was systematically evaluated. Multiple PCR samples taken from single FTA cards demonstrated that a single punch from an FTA card is not sufficient to confirm the infectivity status of an individual animal as parasite DNA is unevenly distributed across the card. At low parasite densities in the host, this stochastic sampling effect results in underestimation of prevalence based on single punch PCR testing. Repeated testing increased the estimated prevalence of all Trypanosoma spp. from 9.7% to 86%. Using repeat testing, a very high prevalence of pathogenic trypanosomes was detected in these local village cattle: T. brucei (34.3%), T. congolense (42.9%) and T. vivax (22.9%). These results show that, despite the convenience of Whatman FTA cards and specific PCR based detection tools, the chronically low parasitaemias in indigenous African zebu cattle make it difficult to establish true prevalence. Although this study specifically applies to FTA cards, a similar effect would be experienced with other approaches using blood samples containing low parasite densities. For example, using blood film microscopy or PCR detection from liquid samples where the probability of detecting a parasite or DNA molecule, in the required number of fields of view or PCR reaction, is less than one.
Constraints to estimating the prevalence of trypanosome infections in East African zebu cattle
2010-01-01
Background In East Africa, animal trypanosomiasis is caused by many tsetse transmitted protozoan parasites including Trypanosoma vivax, T. congolense and subspecies of T. brucei s.l. (T. b. brucei and zoonotic human infective T. b. rhodesiense) that may co-circulate in domestic and wild animals. Accurate species-specific prevalence measurements of these parasites in animal populations are complicated by mixed infections of trypanosomes within individual hosts, low parasite densities and difficulties in conducting field studies. Many Polymerase Chain Reaction (PCR) based diagnostic tools are available to characterise and quantify infection in animals. These are important for assessing the contribution of infections in animal reservoirs and the risk posed to humans from zoonotic trypanosome species. New matrices for DNA capture have simplified large scale field PCR analyses but few studies have examined the impact of these techniques on prevalence estimations. Results The Whatman FTA matrix has been evaluated using a random sample of 35 village zebu cattle from a population naturally exposed to trypanosome infection. Using a generic trypanosome-specific PCR, prevalence was systematically evaluated. Multiple PCR samples taken from single FTA cards demonstrated that a single punch from an FTA card is not sufficient to confirm the infectivity status of an individual animal as parasite DNA is unevenly distributed across the card. At low parasite densities in the host, this stochastic sampling effect results in underestimation of prevalence based on single punch PCR testing. Repeated testing increased the estimated prevalence of all Trypanosoma spp. from 9.7% to 86%. Using repeat testing, a very high prevalence of pathogenic trypanosomes was detected in these local village cattle: T. brucei (34.3%), T. congolense (42.9%) and T. vivax (22.9%). Conclusions These results show that, despite the convenience of Whatman FTA cards and specific PCR based detection tools, the chronically low parasitaemias in indigenous African zebu cattle make it difficult to establish true prevalence. Although this study specifically applies to FTA cards, a similar effect would be experienced with other approaches using blood samples containing low parasite densities. For example, using blood film microscopy or PCR detection from liquid samples where the probability of detecting a parasite or DNA molecule, in the required number of fields of view or PCR reaction, is less than one. PMID:20815940
Code of Federal Regulations, 2011 CFR
2011-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND INSPECTIONS Design Verification and Periodic Testing for Automatic Auxiliary Boilers § 61.35-1 General. (a) All automatic... equipment must be tested and inspected to verify their proper design, construction, installation, and...
Iridovirus CARD Protein Inhibits Apoptosis through Intrinsic and Extrinsic Pathways
Chen, Chien-Wen; Wu, Ming-Shan; Huang, Yi-Jen; Lin, Pei-Wen; Shih, Chueh-Ju; Lin, Fu-Pang; Chang, Chi-Yao
2015-01-01
Grouper iridovirus (GIV) belongs to the genus Ranavirus of the family Iridoviridae; the genomes of such viruses contain an anti-apoptotic caspase recruitment domain (CARD) gene. The GIV-CARD gene encodes a protein of 91 amino acids with a molecular mass of 10,505 Daltons, and shows high similarity to other viral CARD genes and human ICEBERG. In this study, we used Northern blot to demonstrate that GIV-CARD transcription begins at 4 h post-infection; furthermore, we report that its transcription is completely inhibited by cycloheximide but not by aphidicolin, indicating that GIV-CARD is an early gene. GIV-CARD-EGFP and GIV-CARD-FLAG recombinant proteins were observed to translocate from the cytoplasm into the nucleus, but no obvious nuclear localization sequence was observed within GIV-CARD. RNA interference-mediated knockdown of GIV-CARD in GK cells infected with GIV inhibited expression of GIV-CARD and five other viral genes during the early stages of infection, and also reduced GIV infection ability. Immunostaining was performed to show that apoptosis was effectively inhibited in cells expressing GIV-CARD. HeLa cells irradiated with UV or treated with anti-Fas antibody will undergo apoptosis through the intrinsic and extrinsic pathways, respectively. However, over-expression of recombinant GIV-CARD protein in HeLa cells inhibited apoptosis induced by mitochondrial and death receptor signaling. Finally, we report that expression of GIV-CARD in HeLa cells significantly reduced the activities of caspase-8 and -9 following apoptosis triggered by anti-Fas antibody. Taken together, these results demonstrate that GIV-CARD inhibits apoptosis through both intrinsic and extrinsic pathways. PMID:26047333
46 CFR 61.30-20 - Automatic control and safety tests.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Automatic control and safety tests. 61.30-20 Section 61.30-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC... and safety tests. Operational tests and checks of all safety and limit controls, combustion controls...
46 CFR 61.30-20 - Automatic control and safety tests.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Automatic control and safety tests. 61.30-20 Section 61.30-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC... and safety tests. Operational tests and checks of all safety and limit controls, combustion controls...
46 CFR 61.30-20 - Automatic control and safety tests.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Automatic control and safety tests. 61.30-20 Section 61.30-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC... and safety tests. Operational tests and checks of all safety and limit controls, combustion controls...
49 CFR 236.588 - Periodic test.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.588 Periodic test. Except as provided in § 236.586, periodic test of the automatic train stop, train control, or cab signal apparatus...
14 CFR 33.87 - Endurance test.
Code of Federal Regulations, 2011 CFR
2011-01-01
... particular engine being tested. (2) Any automatic engine control that is part of the engine must control the engine during the endurance test except for operations where automatic control is normally overridden by manual control or where manual control is otherwise specified for a particular test run. (3) Except as...
14 CFR 33.87 - Endurance test.
Code of Federal Regulations, 2012 CFR
2012-01-01
... particular engine being tested. (2) Any automatic engine control that is part of the engine must control the engine during the endurance test except for operations where automatic control is normally overridden by manual control or where manual control is otherwise specified for a particular test run. (3) Except as...
Patron ID Cards Made Easy and Cheap
ERIC Educational Resources Information Center
Peischl, Tom
1978-01-01
Four major problems of academic library identification cards are expense, distribution, timeliness, and validation. By moving from a commercially produced plastic library card to a locally produced paper IBM-type card, this library solved these four library card problems. (Author)
A Low-Cost, Efficient, Machine-Assisted Manual Circulation System
ERIC Educational Resources Information Center
Stangl, Peter
1975-01-01
A circulation system uses plastic embossed user cards, an addressograph electric imprinter, a copy of the catalog card as a book card, and a pocket imprinted by the user's card and holding the book card during circulation. (LS)
The TOEFL Trump Card: An Investigation of Test Impact in an ESL Classroom
ERIC Educational Resources Information Center
Johnson, Karen E.; Jordan, Stefanie Rehn; Poehner, Matthew E.
2005-01-01
Much of the research on the effects of tests on foreign and second-language classrooms has examined the impact or washback effect that commercial/institutional language tests, such as the TOEFL, have on teachers' instructional practices (Hughes, 1998; Wall & Alderson, 1993). Using a case study methodology, this study uncovered the ways in…
The Use of Personal Information Technology in Military Area of Operations
2013-04-19
Mauhew FlrDll Approved: .19. Fly. DiI !e:(c=i , . imes f ut T T a l nt (’J11 i 1 b s rscml i at i: llOl lY l ta " TTED LL E U · in Of(l l...more capable and enable Coast Guard members to access the network. The Defense department is testing Android and iOS devices with CAC card ...Access Card authorizes use on desktop computers.48 Another item of concern as the military attempts to move into the PIT realm is who is making the
10 CFR 431.242 - Test Procedures [Reserved
Code of Federal Regulations, 2014 CFR
2014-01-01
..., automatically operated, fossil fuel-fired appliance that is designed to automatically open the flue outlet... individual, automatically operated, fossil fuel-fired appliance either in the outlet or downstream of the...
10 CFR 431.242 - Test Procedures [Reserved
Code of Federal Regulations, 2012 CFR
2012-01-01
..., automatically operated, fossil fuel-fired appliance that is designed to automatically open the flue outlet... individual, automatically operated, fossil fuel-fired appliance either in the outlet or downstream of the...
10 CFR 431.242 - Test Procedures [Reserved
Code of Federal Regulations, 2013 CFR
2013-01-01
..., automatically operated, fossil fuel-fired appliance that is designed to automatically open the flue outlet... individual, automatically operated, fossil fuel-fired appliance either in the outlet or downstream of the...
Design and implementation of a general and automatic test platform base on NI PXI system
NASA Astrophysics Data System (ADS)
Shi, Long
2018-05-01
Aiming at some difficulties of test equipment such as the short product life, poor generality and high development cost, a general and automatic test platform base on NI PXI system is designed in this paper, which is able to meet most test requirements of circuit boards. The test platform is devided into 5 layers, every layer is introduced in detail except for the "Equipment Under Test" layer. An output board of a track-side equipment, which is an important part of high speed train control system, is taken as an example to make the functional circuit test by the test platform. The results show that the test platform is easy to realize add-on functions development, automatic test, wide compatibility and strong generality.
Pholwat, Suporn; Liu, Jie; Stroup, Suzanne; Gratz, Jean; Banu, Sayera; Rahman, S M Mazidur; Ferdous, Sara Sabrina; Foongladda, Suporn; Boonlert, Duangjai; Ogarkov, Oleg; Zhdanova, Svetlana; Kibiki, Gibson; Heysell, Scott; Houpt, Eric
2015-02-24
Genotypic methods for drug susceptibility testing of Mycobacterium tuberculosis are desirable to speed the diagnosis and proper therapy of tuberculosis (TB). However, the numbers of genes and polymorphisms implicated in resistance have proliferated, challenging diagnostic design. We developed a microfluidic TaqMan array card (TAC) that utilizes both sequence-specific probes and high-resolution melt analysis (HRM), providing two layers of detection of mutations. Twenty-seven primer pairs and 40 probes were designed to interrogate 3,200 base pairs of critical regions of the inhA, katG, rpoB, embB, rpsL, rrs, eis, gyrA, gyrB, and pncA genes. The method was evaluated on 230 clinical M. tuberculosis isolates from around the world, and it yielded 96.1% accuracy (2,431/2,530) in comparison to that of Sanger sequencing and 87% accuracy in comparison to that of the slow culture-based susceptibility testing. This TAC-HRM method integrates assays for 10 genes to yield fast, comprehensive, and accurate drug susceptibility results for the 9 major antibiotics used to treat TB and could be deployed to improve treatment outcomes. Multidrug-resistant tuberculosis threatens global tuberculosis control efforts. Optimal therapy utilizes susceptibility test results to guide individualized treatment regimens; however, the susceptibility testing methods in use are technically difficult and slow. We developed an integrated TaqMan array card method with high-resolution melt analysis that interrogates 10 genes to yield a fast, comprehensive, and accurate drug susceptibility result for the 9 major antituberculosis antibiotics. Copyright © 2015 Pholwat et al.
Turgeon, David K; Novicki, Thomas J; Quick, John; Carlson, LaDonna; Miller, Pat; Ulness, Bruce; Cent, Anne; Ashley, Rhoda; Larson, Ann; Coyle, Marie; Limaye, Ajit P; Cookson, Brad T; Fritsche, Thomas R
2003-02-01
Clostridium difficile is one of the most frequent causes of nosocomial gastrointestinal disease. Risk factors include prior antibiotic therapy, bowel surgery, and the immunocompromised state. Direct fecal analysis for C. difficile toxin B by tissue culture cytotoxin B assay (CBA), while only 60 to 85% sensitive overall, is a common laboratory method. We have used 1,003 consecutive, nonduplicate fecal samples to compare six commercially available immunoassays (IA) for C. difficile detection with CBA: Prima System Clostridium difficile Tox A and VIDAS Clostridium difficile Tox A II, which detect C. difficile toxin A; Premier Cytoclone A/B and Techlab Clostridium difficile Tox A/B, which detect toxins A and B; and ImmunoCard Clostridium difficile and Triage Micro C. difficile panels, which detect toxin A and a species-specific antigen. For all tests, Triage antigen was most sensitive (89.1%; negative predictive value [NPV] = 98.7%) while ImmunoCard was most specific (99.7%; positive predictive value [PPV] = 95.0%). For toxin tests only, Prima System had the highest sensitivity (82.2%; NPV = 98.0%) while ImmunoCard had the highest specificity (99.7%; PPV = 95.0%). Hematopoietic stem cell transplant (HSCT) patients contributed 44.7% of all samples tested, and no significant differences in sensitivity or specificity were noted between HSCT and non-HSCT patients. IAs, while not as sensitive as direct fecal CBA, produce reasonable predictive values, especially when both antigen and toxin are detected. They also offer significant advantages over CBA in terms of turnaround time and ease of use.
Family Registration Card as electronic medical carrier in Bosnia and Herzegovina.
Novo, Ahmed; Masic, Izet; Toromanovic, Selim; Loncarevic, Nedim; Junuzovic, Dzelaludin; Dizdarevic, Jadranka
2004-01-01
Medical documentation is a very important part of the medical documentalistics and is occupies a large part of daily work of medical staff working in Primary Health Care. Paper documentation is going to be replaced by electronic cards in Bosnia and Herzegovina and a new Health Care System is under development, based on an Electronic Family Registration Card. Developed countries proceeded from the manual and semiautomatic method of medical data processing to the new method of entering, storage, transferring, searching and protecting data, using electronic equipment. Currently, many European countries have developed a Medical Card Based Electronic Information System. Three types of electronic card are currently in use: a Hybrid Card, a Smart Card and a Laser Card. The dilemma is which card should be used as a data carrier. The Electronic Family Registration Cared is a question of strategic interest for B&H, but also a great investment. We should avoid the errors of other countries that have been developing card-based system. In this article we present all mentioned cards and compare advantages and disadvantages of different technologies.
Report on Phase 1 Tests of Fairchild Automatic Vehicle Monitoring (AVM) System
DOT National Transportation Integrated Search
1977-08-01
During the winter of 1976-77 four different techniques for automatically locating land vehicles were tested in both the low and high-rise regions in Philadelphia, Pennsylvania. The tests were carried out by four different companies under separate con...
Optical Automatic Car Identification (OACI) Field Test Program
DOT National Transportation Integrated Search
1976-05-01
The results of the Optical Automatic Car Identification (OACI) tests at Chicago conducted from August 16 to September 4, 1975 are presented. The main purpose of this test was to determine the suitability of optics as a principle of operation for an a...
McCabe, David P; Roediger, Henry L; Karpicke, Jeffrey D
2011-04-01
Dual-process theories of retrieval suggest that controlled and automatic processing contribute to memory performance. Free recall tests are often considered pure measures of recollection, assessing only the controlled process. We report two experiments demonstrating that automatic processes also influence free recall. Experiment 1 used inclusion and exclusion tasks to estimate recollection and automaticity in free recall, adopting a new variant of the process dissociation procedure. Dividing attention during study selectively reduced the recollection estimate but did not affect the automatic component. In Experiment 2, we replicated the results of Experiment 1, and subjects additionally reported remember-know-guess judgments during recall in the inclusion condition. In the latter task, dividing attention during study reduced remember judgments for studied items, but know responses were unaffected. Results from both methods indicated that free recall is partly driven by automatic processes. Thus, we conclude that retrieval in free recall tests is not driven solely by conscious recollection (or remembering) but also by automatic influences of the same sort believed to drive priming on implicit memory tests. Sometimes items come to mind without volition in free recall.
Gas cooled traction drive inverter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chinthavali, Madhu Sudhan
The present invention provides a modular circuit card configuration for distributing heat among a plurality of circuit cards. Each circuit card includes a housing adapted to dissipate heat in response to gas flow over the housing. In one aspect, a gas-cooled inverter includes a plurality of inverter circuit cards, and a plurality of circuit card housings, each of which encloses one of the plurality of inverter cards.
Gas cooled traction drive inverter
Chinthavali, Madhu Sudhan
2013-10-08
The present invention provides a modular circuit card configuration for distributing heat among a plurality of circuit cards. Each circuit card includes a housing adapted to dissipate heat in response to gas flow over the housing. In one aspect, a gas-cooled inverter includes a plurality of inverter circuit cards, and a plurality of circuit card housings, each of which encloses one of the plurality of inverter cards.
2012-04-24
Expedition 31 NASA backup crew member Kevin Ford, left, Oleg Novitskiy and Evgeny Tarelkin, third from left, select International Space Station Russian segment event simulation test cards for their final qualification test in preparation for flight, Tuesday, April 24, 2012 at the Gagarin Cosmonaut Training Center in Star City, Russia. Photo Credit: (NASA/Carla Cioffi)
A Comparison of Piagetian Conservation Concepts with Reading Achievement.
ERIC Educational Resources Information Center
Caballero, Jane Alexis
This study involved a comparison of first and second grade students' performance on the Piagetian Task Administration Instrument (PTAI), the Metropolitan Readiness Test (MRT), and the Stanford Achievement Test (SAT) with actual reading achievement measured by placement on the Indiviudally Paced Instruction (IPI) Tracking Card in Reading, which was…
The Michigan Public High School Context and Performance Report Card
ERIC Educational Resources Information Center
Van Beek, Michael; Bowen, Daniel; Mills, Jonathan
2012-01-01
Assessing a high school's effectiveness is not straightforward. Comparing a school's standardized test scores to those of other schools is one approach to measuring effectiveness, but a major objection to this method is that students' test scores tend to be related to students' "socioeconomic" status--family household income, for…
A Database System for Course Administration.
ERIC Educational Resources Information Center
Benbasat, Izak; And Others
1982-01-01
Describes a computer-assisted testing system which produces multiple-choice examinations for a college course in business administration. The system uses SPIRES (Stanford Public Information REtrieval System) to manage a database of questions and related data, mark-sense cards for machine grading tests, and ACL (6) (Audit Command Language) to…
Clothes Dryer Automatic Termination Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
TeGrotenhuis, Ward E.
Volume 2: Improved Sensor and Control Designs Many residential clothes dryers on the market today provide automatic cycles that are intended to stop when the clothes are dry, as determined by the final remaining moisture content (RMC). However, testing of automatic termination cycles has shown that many dryers are susceptible to over-drying of loads, leading to excess energy consumption. In particular, tests performed using the DOE Test Procedure in Appendix D2 of 10 CFR 430 subpart B have shown that as much as 62% of the energy used in a cycle may be from over-drying. Volume 1 of this reportmore » shows an average of 20% excess energy from over-drying when running automatic cycles with various load compositions and dryer settings. Consequently, improving automatic termination sensors and algorithms has the potential for substantial energy savings in the U.S.« less
Passive microfluidic array card and reader
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dugan, Lawrence Christopher; Coleman, Matthew A
A microfluidic array card and reader system for analyzing a sample. The microfluidic array card includes a sample loading section for loading the sample onto the microfluidic array card, a multiplicity of array windows, and a transport section or sections for transporting the sample from the sample loading section to the array windows. The microfluidic array card reader includes a housing, a receiving section for receiving the microfluidic array card, a viewing section, and a light source that directs light to the array window of the microfluidic array card and to the viewing section.
Medication safety--reliability of preference cards.
Dawson, Anthony; Orsini, Michael J; Cooper, Mary R; Wollenburg, Karol
2005-09-01
A CLINICAL ANALYSIS of surgeons' preference cards was initiated in one hospital as part of a comprehensive analysis to reduce medication-error risks by standardizing and simplifying the intraoperative medication-use process specific to the sterile field. THE PREFERENCE CARD ANALYSIS involved two subanalyses: a review of the information as it appeared on the cards and a failure mode and effects analysis of the process involved in using and maintaining the cards. THE ANALYSIS FOUND that the preference card system in use at this hospital is outdated. Variations and inconsistencies within the preference card system indicate that the use of preference cards as guides for medication selection for surgical procedures presents an opportunity for medication errors to occur.
NASA Astrophysics Data System (ADS)
Kardas, Edyta; Brožova, Silvie; Pustějovská, Pavlína; Jursová, Simona
2017-12-01
In the paper the evaluation of efficiency of the use of machines in the selected production company was presented. The OEE method (Overall Equipment Effectiveness) was used for the analysis. The selected company deals with the production of tapered roller bearings. The analysis of effectiveness was done for 17 automatic grinding lines working in the department of grinding rollers. Low level of efficiency of machines was affected by problems with the availability of machines and devices. The causes of machine downtime on these lines was also analyzed. Three basic causes of downtime were identified: no kanban card, diamonding, no operator. Ways to improve the use of these machines were suggested. The analysis takes into account the actual results from the production process and covers the period of one calendar year.
Secure Distributed Human Computation
NASA Astrophysics Data System (ADS)
Gentry, Craig; Ramzan, Zulfikar; Stubblebine, Stuart
In Peha’s Financial Cryptography 2004 invited talk, he described the Cyphermint PayCash system (see www.cyphermint.com), which allows people without bank accounts or credit cards (a sizeable segment of the U.S. population) to automatically and instantly cash checks, pay bills, or make Internet transactions through publicly-accessible kiosks. Since PayCash offers automated financial transactions and since the system uses (unprotected) kiosks, security is critical. The kiosk must decide whether a person cashing a check is really the person to whom the check was made out, so it takes a digital picture of the person cashing the check and transmits this picture electronically to a central office, where a human worker compares the kiosk’s picture to one that was taken when the person registered with Cyphermint. If both pictures are of the same person, then the human worker authorizes the transaction.
Microprocessor controlled portable TLD system
NASA Technical Reports Server (NTRS)
Apathy, I.; Deme, S.; Feher, I.
1996-01-01
An up-to-date microprocessor controlled thermoluminescence dosemeter (TLD) system for environmental and space dose measurements has been developed. The earlier version of the portable TLD system, Pille, was successfully used on Soviet orbital stations as well as on the US Space Shuttle, and for environmental monitoring. The new portable TLD system, Pille'95, consists of a reader and TL bulb dosemeters, and each dosemeter is provided with an EEPROM chip for automatic identification. The glow curve data are digitised and analysed by the program of the reader. The measured data and the identification number appear on the LED display of the reader. Up to several thousand measured data together with the glow curves can be stored on a removable flash memory card. The whole system is supplied either from built-in rechargeable batteries or from the mains of the space station.
Qin, Juan-Juan; Mao, Wenzhe; Wang, Xiaozhan; Sun, Peng; Cheng, Daqing; Tian, Song; Zhu, Xue-Yong; Yang, Ling; Huang, Zan; Li, Hongliang
2018-06-26
The comprehensive interplay in sterile inflammation and liver cell death predominantly determines hepatic injury caused by ischemia/reperfusion (I/R) insult. Caspase recruitment domain family member 6 (CARD6) was initially shown to play important roles in NF-κB activation. In our preliminary studies, CARD6 downregulation was closely related to hepatic I/R injury in liver transplantation patients and mouse models. Thus, we hypothesized that CARD6 protects against hepatic I/R injury and investigated the underlying molecular mechanisms. A partial hepatic I/R operation was performed in hepatocyte-specific Card6 knockout mice (HKO), Card6 transgenic mice with CARD6 overexpression specifically in hepatocytes (HTG), and the corresponding control mice. Hepatic histology, serum aminotransferase, inflammatory cytokines/chemokines, cell death, and inflammatory signaling were examined to assess liver damage. The molecular mechanisms of CARD6 function were explored in vivo and in vitro. Card6-HTG mice alleviated liver injury compared with control mice as shown by decreased cell death, lower serum transaminase levels, and reduced inflammation and infiltration, whereas Card6-HKO mice had the opposite phenotype. Mechanistically, phosphorylation of ASK1 and its downstream effectors JNK and p38 were increased in the livers of Card6-HKO mice but repressed in those of Card6-HTG mice. Furthermore, ASK1 knockdown normalized the effect of CARD6 deficiency on the activation of NF-κB, JNK and p38, while ASK1 overexpression abrogated the suppressive effect of CARD6. Finally, CARD6 interacted with Ask1. Mutant CARD6 that lacked the ability to interact with ASK1 could not inhibit ASK1 and failed to protect against hepatic I/R injury. CARD6 is a novel protective factor of hepatic I/R injury that suppresses inflammation and liver cell death by inhibiting the ASK1 signaling pathway. CARD6 participate and play an important role during the process of liver blood flow restriction followed by restoring. Through suppressing the activity of ASK1, CARD6 can protect against hepatocytes injury. Targeting CARD6 can be a strategy for precaution and treatment of this disease. Copyright © 2018 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
48 CFR 32.1108 - Payment by Governmentwide commercial purchase card.
Code of Federal Regulations, 2010 CFR
2010-10-01
... commercial purchase card. 32.1108 Section 32.1108 Federal Acquisition Regulations System FEDERAL ACQUISITION... Governmentwide commercial purchase card. A Governmentwide commercial purchase card charge authorizes the third party (e.g., financial institution) that issued the purchase card to make immediate payment to the...
75 FR 10414 - Researcher Identification Card
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-08
... capturing administrative information on the characteristics of our users. Other forms of identification are... use bar-codes on researcher identification cards in the Washington, DC, area. The plastic cards we... plastic researcher identification cards as part of their security systems, we issue a plastic card to...
48 CFR 2913.301 - Governmentwide commercial purchase card.
Code of Federal Regulations, 2010 CFR
2010-10-01
... purchase card. 2913.301 Section 2913.301 Federal Acquisition Regulations System DEPARTMENT OF LABOR... commercial purchase card. (a) The Government purchase card has far fewer requirements for documentation than other methods of purchasing. However, the same legal restrictions apply to credit card purchases that...
ERIC Educational Resources Information Center
Rodriguez-Aranda, Claudia; Sundet, Kjetil
2006-01-01
With 101 healthy aging adult participants, the authors investigated whether executive functions are a unitary concept. The authors established the factor structure of the Wisconsin Card Sorting Test (WCST; E. A. Berg, 1948), the Stroop color and word test (C. J. Golden, 1978), verbal fluency using the Controlled Oral Word Association Test (COWAT;…
You Can Teach an Old Magician New Tricks
ERIC Educational Resources Information Center
Bonomo, John P.
2008-01-01
Mathematics forms the basis for many types of card tricks. One of the best-known works as follows: Take any 15 cards out of a deck and ask a volunteer to select one of the cards and place it back in the deck. After shuffling the cards, you deal out three piles of cards and ask the volunteer which pile his or her card is in. You collect up the…
Correlates of credit card ownership in men and women.
Yang, Bijou; Lester, David
2005-06-01
In a sample of 352 students, correlates of credit card ownership differed by sex. For both men and women, credit card ownership was predicted by their affective attitude toward credit cards. However, whereas for men concern with money as a tactic for gaining power predicted credit card ownership, for women feelings of insecurity about having sufficient money and having a conservative approach to money predicted credit card ownership.
Renna, Tania Di; Crooks, Simone; Pigford, Ashlee-Ann; Clarkin, Chantalle; Fraser, Amy B; Bunting, Alexandra C; Bould, M Dylan; Boet, Sylvain
2016-09-01
This study aimed to assess the perceived value of the Cognitive Aids for Role Definition (CARD) protocol for simulated intraoperative cardiac arrests. Sixteen interprofessional operating room teams completed three consecutive simulated intraoperative cardiac arrest scenarios: current standard, no CARD; CARD, no CARD teaching; and CARD, didactic teaching. Each team participated in a focus group interview immediately following the third scenario; data were transcribed verbatim and qualitatively analysed. After 6 months, participants formed eight new teams randomised to two groups (CARD or no CARD) and completed a retention intraoperative cardiac arrest simulation scenario. All simulation sessions were video recorded and expert raters assessed team performance. Qualitative analysis of the 16 focus group interviews revealed 3 thematic dimensions: role definition in crisis management; logistical issues; and the "real life" applicability of CARD. Members of the interprofessional team perceived CARD very positively. Exploratory quantitative analysis found no significant differences in team performance with or without CARD (p > 0.05). In conclusion, qualitative data suggest that the CARD protocol clarifies roles and team coordination during interprofessional crisis management and has the potential to improve the team performance. The concept of a self-organising team with defined roles is promising for patient safety.
Code of Federal Regulations, 2011 CFR
2011-01-01
... may conduct a review of the test records. The Secretary may then conduct enforcement testing of that...) For automatic commercial ice makers, as well as commercial refrigerators, freezers, and refrigerator... numbers to select the units to be tested. (ii) For automatic commercial ice makers, as well as commercial...
The charging security study of electric vehicle charging spot based on automatic testing platform
NASA Astrophysics Data System (ADS)
Li, Yulan; Yang, Zhangli; Zhu, Bin; Ran, Shengyi
2018-03-01
With the increasing of charging spots, the testing of charging security and interoperability becomes more and more urgent and important. In this paper, an interface simulator for ac charging test is designed, the automatic testing platform for electric vehicle charging spots is set up and used to test and analyze the abnormal state during the charging process. On the platform, the charging security and interoperability of ac charging spots and IC-CPD can be checked efficiently, the test report can be generated automatically with No artificial reading error. From the test results, the main reason why the charging spot is not qualified is that the power supply cannot be cut off in the prescribed time when the charging anomaly occurs.
Evolution of a Novel Antiviral Immune-Signaling Interaction by Partial-Gene Duplication
Korithoski, Bryan; Kolaczkowski, Oralia; Mukherjee, Krishanu; Kola, Reema; Earl, Chandra; Kolaczkowski, Bryan
2015-01-01
The RIG-like receptors (RLRs) are related proteins that identify viral RNA in the cytoplasm and activate cellular immune responses, primarily through direct protein-protein interactions with the signal transducer, IPS1. Although it has been well established that the RLRs, RIG-I and MDA5, activate IPS1 through binding between the twin caspase activation and recruitment domains (CARDs) on the RLR and a homologous CARD on IPS1, it is less clear which specific RLR CARD(s) are required for this interaction, and almost nothing is known about how the RLR-IPS1 interaction evolved. In contrast to what has been observed in the presence of immune-modulating K63-linked polyubiquitin, here we show that—in the absence of ubiquitin—it is the first CARD domain of human RIG-I and MDA5 (CARD1) that binds directly to IPS1 CARD, and not the second (CARD2). Although the RLRs originated in the earliest animals, both the IPS1 gene and the twin-CARD domain architecture of RIG-I and MDA5 arose much later in the deuterostome lineage, probably through a series of tandem partial-gene duplication events facilitated by tight clustering of RLRs and IPS1 in the ancestral deuterostome genome. Functional differentiation of RIG-I CARD1 and CARD2 appears to have occurred early during this proliferation of RLR and related CARDs, potentially driven by adaptive coevolution between RIG-I CARD domains and IPS1 CARD. However, functional differentiation of MDA5 CARD1 and CARD2 occurred later. These results fit a general model in which duplications of protein-protein interaction domains into novel gene contexts could facilitate the expansion of signaling networks and suggest a potentially important role for functionally-linked gene clusters in generating novel immune-signaling pathways. PMID:26356745
48 CFR 552.232-77 - Payment By Government Charge Card.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Charge Card. 552.232-77 Section 552.232-77 Federal Acquisition Regulations System GENERAL SERVICES....232-77 Payment By Government Charge Card. As prescribed in 532.7003, insert the following clause: Payment By Government Charge Card (NOV 2009) (a) Definitions. “Governmentwide commercial purchase card...
El-Sadr, Wafaa M; Donnell, Deborah; Beauchamp, Geetha; Hall, H Irene; Torian, Lucia V; Zingman, Barry; Lum, Garret; Kharfen, Michael; Elion, Richard; Leider, Jason; Gordin, Fred M; Elharrar, Vanessa; Burns, David; Zerbe, Allison; Gamble, Theresa; Branson, Bernard
2017-08-01
Achieving linkage to care and viral suppression in human immunodeficiency virus (HIV)-positive patients improves their well-being and prevents new infections. Current gaps in the HIV care continuum substantially limit such benefits. To evaluate the effectiveness of financial incentives on linkage to care and viral suppression in HIV-positive patients. A large community-based clinical trial that randomized 37 HIV test and 39 HIV care sites in the Bronx, New York, and Washington, DC, to financial incentives or standard of care. Participants at financial incentive test sites who had positive test results for HIV received coupons redeemable for $125 cash-equivalent gift cards upon linkage to care. HIV-positive patients receiving antiretroviral therapy at financial incentive care sites received $70 gift cards quarterly, if virally suppressed. Linkage to care: proportion of HIV-positive persons at the test site who linked to care within 3 months, as indicated by CD4+ and/or viral load test results done at a care site. Viral suppression: proportion of established patients at HIV care sites with suppressed viral load (<400 copies/mL), assessed at each calendar quarter. Outcomes assessed through laboratory test results reported to the National HIV Surveillance System. A total of 1061 coupons were dispensed for linkage to care at 18 financial incentive test sites and 39 359 gift cards were dispensed to 9641 HIV-positive patients eligible for gift cards at 17 financial incentive care sites. Financial incentives did not increase linkage to care (adjusted odds ratio, 1.10; 95% CI, 0.73-1.67; P = .65). However, financial incentives significantly increased viral suppression. The overall proportion of patients with viral suppression was 3.8% higher (95% CI, 0.7%-6.8%; P = .01) at financial incentive sites compared with standard of care sites. Among patients not previously consistently virally suppressed, the proportion virally suppressed was 4.9% higher (95% CI, 1.4%-8.5%; P = .007) at financial incentive sites. In addition, continuity in care was 8.7% higher (95% CI, 4.2%-13.2%; P < .001) at financial incentive sites. Financial incentives, as used in this study (HPTN 065), significantly increased viral suppression and regular clinic attendance among HIV-positive patients in care. No effect was noted on linkage to care. Financial incentives offer promise for improving adherence to treatment and viral suppression among HIV-positive patients. clinicaltrials.gov Identifier: NCT01152918.
Batnini, Soulef; Uno, Akira
2015-06-01
This study investigated first the main cognitive abilities; phonological processing, visual cognition, automatization and receptive vocabulary in predicting reading and spelling abilities in Arabic. Second, we compared good/poor readers and spellers to detect the characteristics of cognitive predictors which contribute to identifying reading and spelling difficulties in Arabic speaking children. A sample of 116 Tunisian third-grade children was tested on their abilities to read and spell, phonological processing, visual cognition, automatization and receptive vocabulary. For reading, phonological processing and automatization uniquely predicted Arabic word reading and paragraph reading abilities. Automatization uniquely predicted Arabic non-word reading ability. For spelling, phonological processing was a unique predictor for Arabic word spelling ability. Furthermore, poor readers had significantly lower scores on the phonological processing test and slower reading times on the automatization test as compared with good readers. Additionally, poor spellers showed lower scores on the phonological processing test as compared with good spellers. Visual cognitive processing and receptive vocabulary were not significant cognitive predictors of Arabic reading and spelling abilities for Tunisian third grade children in this study. Our results are consistent with previous studies in alphabetic orthographies and demonstrate that phonological processing and automatization are the best cognitive predictors in detecting early literacy problems. We suggest including phonological processing and automatization tasks in screening tests and in intervention programs may help Tunisian children with poor literacy skills overcome reading and spelling difficulties in Arabic. Copyright © 2014 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.
Chaillet, Pascale; Tayler-Smith, Katie; Zachariah, Rony; Duclos, Nanfack; Moctar, Diallo; Beelaert, Greet; Fransen, Katrien
2010-09-01
With both HIV-1 and HV-2 prevalent in Guinea-Conakry, accurate diagnosis and differentiation is crucial for treatment purposes. Thus, four rapid HIV tests were evaluated for their HIV-1 and HIV-2 diagnostic and discriminative capacity for use in Guinea-Conakry. These included SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), Genie II HIV1/HIV2 (Bio-Rad), First Response HIV Card Test 1-2.0 (PMC Medical) and Immunoflow HIV1-HIV2 (Core Diagnostics). Results were compared with gold standard tests (INNO-LIA HIV-I/II Score) and NEW LAV BLOT II (Bio-Rad). Four hundred and forty three sequential stored HIV-positive serum samples, of known HIV-type, were evaluated. Genie II HIV1/HIV2, Immunoflow HIV1-HIV2 and SD Bioline HIV 1/2 3.0 had 100% sensitivity (95% CI, 98.9-100%) while for First Response HIV Card Test 1-2.0 this was 99.5% (95% CI, 98.2%-99.9%). In terms of discriminatory capacity, Genie II HIV1/HIV2 identified 382/ 384(99.5%) HIV-1 samples, 49/ 52(95%) HIV-2 and 7/7(100%) HIV-positive untypable samples. Immunoflow HIV1-HIV2 identified 99% HIV-1, 67% HIV-2 and all HIV-positive untypable samples. First Response HIV Card Test 1-2.0 identified 94% HIV-1, 64% HIV-2 and 57% HIV-positive untypable samples. SD-Bioline HIV 1/2 3.0 was the worst overall performer identifying 65% HIV-1, 69% HIV-2 and all HIV-positive untypable samples. The use of SD Bioline HIV 1/2 3.0 (the current standard in Guinea-Conakry) as a discriminatory HIV test is poor and may be best replaced by Immunoflow HIV1-HIV2. Copyright 2010 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.
da Cunha Santos, Gilda
2018-03-01
- Traditional methods for storing histologic and cytologic specimens for future use in molecular assays have consisted of either snap-freezing with cryopreservation or formalin-fixing, paraffin-embedding the samples. Although snap-freezing with cryopreservation is recommended for better preservation of nucleic acids, the infrastructure and space required for archiving impose challenges for high-volume pathology laboratories. Cost-effective, long-term storage at room temperature; relatively easy shipment; and standardized handling can be achieved with formalin-fixed, paraffin-embedded samples, but formalin fixation induces fragmentation and chemical modification of nucleic acids. Advances in next-generation sequencing platforms, coupled with an increase in diagnostic, prognostic, and predictive molecular biomarkers have created a demand for high-quality nucleic acids. To address issues of the quality of nucleic acid and logistics in sample acquisition, alternatives for specimen preservation and long-term storage have been described and include novel universal tissue fixatives, stabilizers, and technologies. - To collect, retrieve, and review information from studies describing the use of nucleic acids recovered from cytologic/tissue specimens stored on Flinders Technology Associates (FTA, GE Whatman, Maidstone, Kent, United Kingdom) cards for downstream molecular applications. - An electronic literature search in the PubMed (National Center for Biotechnology Information, Bethesda, Maryland) database allowed the selection of manuscripts addressing the use of FTA cards for storage of cytologic samples for molecular analysis. Only articles published in English were retrieved. - The use of FTA cards is a versatile method for fostering multicenter, international collaborations and clinical trials that require centralized testing, long-distance shipment, and high-quality nucleic acids for molecular techniques. Studies with controlled temperature are required to test the quality of recovered RNA after long-term storage.
Rajendram, D; Ayenza, R; Holder, F M; Moran, B; Long, T; Shah, H N
2006-12-01
We assessed the potential use of Whatman FTA paper as a device for archiving and long-term storage of bacterial cell suspensions of over 400 bacterial strains representing 61 genera, the molecular applications of immobilised DNA on FTA paper, and tested its microbial inactivation properties. The FTA paper extracted bacterial DNA is of sufficiently high quality to successfully carryout the molecular detection of several key genes including 16S rRNA, esp (Enterococcus surface protein), Bft (Bacteroides fragilis enterotoxin) and por (porin protein) by PCR and for DNA fingerprinting by random amplified polymorphic DNA-PCR (RAPD-PCR). To test the long-term stability of the FTA immobilised DNA, 100 of the 400 archived bacterial samples were randomly selected following 3 years of storage at ambient temperature and PCR amplification was used to monitor its success. All of the 100 samples were successfully amplified using the 16S rDNA gene as a target and confirmed by DNA sequencing. Furthermore, the DNA was eluted into solution from the FTA cards using a new alkaline elution procedure for evaluation by real-time PCR-based assays. The viability of cells retained on the FTA cards varied among broad groups of bacteria. For the more fragile gram-negative species, no viable cells were retained even at high cell densities of between 10(7) and 10(8) colony forming units (cfu) ml(-1), and for the most robust species such as spore-formers and acid-fast bacteria, complete inactivation was achieved at cell densities ranging between 10(1) and 10(4) cfu ml(-1). The inactivation of bacterial cells on FTA cards suggest that this is a safe medium for the storage and transport of bacterial nucleic acids.
Improving sexually transmitted infection results notification via mobile phone technology.
Reed, Jennifer L; Huppert, Jill S; Taylor, Regina G; Gillespie, Gordon L; Byczkowski, Terri L; Kahn, Jessica A; Alessandrini, Evaline A
2014-11-01
To improve adolescent notification of positive sexually transmitted infection (STI) tests using mobile phone technology and STI information cards. A randomized intervention among 14- to 21-year olds in a pediatric emergency department (PED). A 2 × 3 factorial design with replication was used to evaluate the effectiveness of six combinations of two factors on the proportion of STI-positive adolescents notified within 7 days of testing. Independent factors included method of notification (call, text message, or call + text message) and provision of an STI information card with or without a phone number to obtain results. Covariates for logistic regression included age, empiric STI treatment, days until first attempted notification, and documentation of confidential phone number. Approximately half of the 383 females and 201 males enrolled were ≥18 years of age. Texting only or type of card was not significantly associated with patient notification rates, and there was no significant interaction between card and notification method. For females, successful notification was significantly greater for call + text message (odds ratio, 3.2; 95% confidence interval, 1.4-6.9), and documenting a confidential phone number was independently associated with successful notification (odds ratio, 3.6; 95% confidence interval, 1.7-7.5). We found no significant predictors of successful notification for males. Of patients with a documented confidential phone number who received a call + text message, 94% of females and 83% of males were successfully notified. Obtaining a confidential phone number and using call + text message improved STI notification rates among female but not male adolescents in a pediatric emergency department. Copyright © 2014 Society for Adolescent Health and Medicine. All rights reserved.
Maheshkumar, K; Dilara, K; Maruthy, K N; Sundareswaren, L
2016-07-01
Heart rate variability (HRV) analysis is a simple and noninvasive technique capable of assessing autonomic nervous system modulation on heart rate (HR) in healthy as well as disease conditions. The aim of the present study was to compare (validate) the HRV using a temporal series of electrocardiograms (ECG) obtained by simple analog amplifier with PC-based sound card (audacity) and Biopac MP36 module. Based on the inclusion criteria, 120 healthy participants, including 72 males and 48 females, participated in the present study. Following standard protocol, 5-min ECG was recorded after 10 min of supine rest by Portable simple analog amplifier PC-based sound card as well as by Biopac module with surface electrodes in Leads II position simultaneously. All the ECG data was visually screened and was found to be free of ectopic beats and noise. RR intervals from both ECG recordings were analyzed separately in Kubios software. Short-term HRV indexes in both time and frequency domain were used. The unpaired Student's t-test and Pearson correlation coefficient test were used for the analysis using the R statistical software. No statistically significant differences were observed when comparing the values analyzed by means of the two devices for HRV. Correlation analysis revealed perfect positive correlation (r = 0.99, P < 0.001) between the values in time and frequency domain obtained by the devices. On the basis of the results of the present study, we suggest that the calculation of HRV values in the time and frequency domains by RR series obtained from the PC-based sound card is probably as reliable as those obtained by the gold standard Biopac MP36.
Laurin, Nancy; DeMoors, Anick; Frégeau, Chantal
2012-09-01
Direct amplification of STR loci from biological samples collected on FTA cards without prior DNA purification was evaluated using Identifiler Direct and PowerPlex 16 HS in conjunction with the use of a high throughput Applied Biosystems 3730 DNA Analyzer. In order to reduce the overall sample processing cost, reduced PCR volumes combined with various FTA disk sizes were tested. Optimized STR profiles were obtained using a 0.53 mm disk size in 10 μL PCR volume for both STR systems. These protocols proved effective in generating high quality profiles on the 3730 DNA Analyzer from both blood and buccal FTA samples. Reproducibility, concordance, robustness, sample stability and profile quality were assessed using a collection of blood and buccal samples on FTA cards from volunteer donors as well as from convicted offenders. The new developed protocols offer enhanced throughput capability and cost effectiveness without compromising the robustness and quality of the STR profiles obtained. These results support the use of these protocols for processing convicted offender samples submitted to the National DNA Data Bank of Canada. Similar protocols could be applied to the processing of casework reference samples or in paternity or family relationship testing. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Langner, Robert; Cieslik, Edna C.; Rottschy, Claudia; Eickhoff, Simon B.
2016-01-01
Cognitive flexibility, a core aspect of executive functioning, is required for the speeded shifting between different tasks and sets. Using an interindividual differences approach, we examined whether cognitive flexibility, as assessed by the Delis–Kaplan card-sorting test, is associated with gray matter volume (GMV) and functional connectivity (FC) of regions of a core network of multiple cognitive demands as well as with different facets of trait impulsivity. The core multiple-demand network was derived from three large-scale neuroimaging meta-analyses and only included regions that showed consistent associations with sustained attention, working memory as well as inhibitory control. We tested to what extent self-reported impulsivity as well as GMV and resting-state FC in this core network predicted cognitive flexibility independently and incrementally. Our analyses revealed that card-sorting performance correlated positively with GMV of the right anterior insula, FC between bilateral anterior insula and midcingulate cortex/supplementary motor area as well as the impulsivity dimension “Premeditation.” Importantly, GMV, FC and impulsivity together accounted for more variance of card-sorting performance than every parameter alone. Our results therefore indicate that various factors contribute individually to cognitive flexibility, underlining the need to search across multiple modalities when aiming to unveil the mechanisms behind executive functioning. PMID:24878823
The Contrast Sensitivity of the Newborn Human Infant
Brown, Angela M.; Lindsey, Delwin T.; Cammenga, Joanna G.; Giannone, Peter J.; Stenger, Michael R.
2015-01-01
Purpose. To measure the binocular contrast sensitivity (CS) of newborn infants using a fixation-and-following card procedure. Methods. The CS of 119 healthy newborn infants was measured using stimuli printed on cards under the descending method of limits (93 infants) and randomized/masked designs (26 infants). One experienced and one novice adult observer tested the infants using vertical square-wave gratings (0.06 and 0.10 cyc/deg; 20/10,000 and 20/6000 nominal Snellen equivalent); the experienced observer also tested using horizontal gratings (0.10 cyc/deg) and using the Method of Constant Stimuli while being kept unaware of the stimulus values. Results. The CS of the newborn infant was 2.0 (contrast threshold = 0.497; 95% confidence interval: 0.475–0.524) for vertically oriented gratings and 1.74 (threshold = 0.575; 95% confidence interval: 0.523–0.633) for horizontally oriented gratings (P < 0.0006). The standard deviation of infant CS was comparable to that obtained by others on adults using the Pelli-Robson chart. The two observers showed similar practice effects. Randomization of stimulus order and masking of the adult observer had no effect on CS. Conclusions. The CS of individual newborn human infants can be measured using a fixation-and-following card procedure. PMID:25564453
Niquini, Roberta Pereira; Bittencourt, Sonia Azevedo; Lacerda, Elisa Maria de Aquino; Saunders, Cláudia; Leal, Maria do Carmo
2012-10-01
Nutritional care is of great importance in the prenatal period and the family health teams play a significant role in expanding the coverage of prenatal care. In this manner, the scope of this study was to evaluate the prenatal nutritional care process in seven family health units in the city of Rio de Janeiro. In 2008, a cross-sectional study was conducted and 230 pregnant women were interviewed and copies of their prenatal cards were obtained. The compliance of the process with the pre-established norms and criteria of the Ministry of Health was evaluated. Measurement and recording of blood pressure and weight and prescription of supplements and blood tests on the prenatal card are established steps in routine prenatal care. However, the results indicated that there was under-recording of stature, initial weight, edema, BMI by gestational age and laboratory tests results on the prenatal card. A lack of specific instruction on adequate use of the iron supplement, food consumption and weight gain was observed. The results indicated a pressing need for prenatal nutritional care and revealed deficiencies in this process, stressing the importance of minimum training for the health teams and the implementation of Family Health Support Centers.
Rapid automated method for screening of enteric pathogens from stool specimens.
Villasante, P A; Agulla, A; Merino, F J; Pérez, T; Ladrón de Guevara, C; Velasco, A C
1987-01-01
A total of 800 colonies suggestive of Salmonella, Shigella, or Yersinia species isolated on stool differential agar media were inoculated onto both conventional biochemical test media (triple sugar iron agar, urea agar, and phenylalanine agar) and Entero Pathogen Screen cards of the AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.). Based on the conventional tests, the AutoMicrobic system method yielded the following results: 587 true-negatives, 185 true-positives, 2 false-negatives, and 26 false-positives (sensitivity, 99%; specificity, 96%). Both true-positive and true-negative results were achieved considerably earlier than false results (P less than 0.001). The Entero Pathogen Screen card method is a fast, easy, and sensitive method for screening for Salmonella, Shigella, or Yersinia species. The impossibility of screening for oxidase-positive pathogens is a minor disadvantage of this method. PMID:3553230
Security aspects of RFID communication systems
NASA Astrophysics Data System (ADS)
Bîndar, Valericǎ; Popescu, Mircea; Bǎrtuşicǎ, Rǎzvan; Craciunescu, Razvan; Halunga, Simona
2015-02-01
The objective of this study is to provide an overview of basic technical elements and security risks of RFID communication systems and to analyze the possible threats arising from the use of RFID systems. A number of measurements are performed on a communication system including RFID transponder and the tag reader, and it has been determined that the uplink signal level is 62 dB larger than the average value of the noise at the distance of 1m from the tag, therefore the shielding effectiveness has to exceed this threshold. Next, the card has been covered with several shielding materials and measurements were carried, under similar conditions to test the recovery of compromising signals. A very simple protection measure to prevent unauthorized reading of the data stored on the card has been proposed, and some electromagnetic shielding materials have been proposed and tested.
Definition of propulsion system for V/STOL research and technology aircraft
NASA Technical Reports Server (NTRS)
1977-01-01
Wind tunnel test support, aircraft contractor support, a propulsion system computer card deck, preliminary design studies, and propulsion system development plan are reported. The Propulsion system consists of two lift/cruise turbofan engines, one turboshaft engine and one lift fan connected together with shafting into a combiner gearbox. Distortion parameter levels from 40 x 80 test data were within the established XT701-AD-700 limits. The three engine-three fan system card deck calculates either vertical or conventional flight performance, installed or uninstalled. Design study results for XT701 engine modifications, bevel gear cross shaft location, fixed and tilt fan frames and propulsion system controls are described. Optional water-alcohol injection increased total net thrust 10.3% on a 90 F day. Engines have sufficient turbine life for 500 hours of the RTA duty cycle.
NASA Technical Reports Server (NTRS)
Watson, D. M.; Hardy, G. H.; Warner, D. N., Jr.
1983-01-01
An automatic landing system was developed for the Augmentor Wing Jet STOL Research Airplane to establish the feasibility and examine the operating characteristics of a powered-lift STOL transport flying a steep, microwave landing system (MLS) glide slope to automatically land on a STOL port. The flight test results address the longitudinal aspects of automatic powered lift STOL airplane operation including glide slope tracking on the backside of the power curve, flare, and touchdown. Three different autoland control laws were evaluated to demonstrate the tradeoff between control complexity and the resulting performance. The flight test and simulation methodology used in developing conventional jet transport systems was applied to the powered-lift STOL airplane. The results obtained suggest that an automatic landing system for a powered-lift STOL airplane operating into an MLS-equipped STOL port is feasible. However, the airplane must be provided with a means of rapidly regulation lift to satisfactorily provide the glide slope tracking and control of touchdown sink rate needed for automatic landings.
Credit Cards. Bulletin No. 721. (Revised.)
ERIC Educational Resources Information Center
Fox, Linda Kirk
This cooperative extension bulletin provides basic information about credit cards and their use. It covers the following topics: types of credit cards (revolving credit, travel and entertainment, and debit); factors to consider when evaluating a credit card (interest rates, grace period, and annual membership fee); other credit card costs (late…
Code of Federal Regulations, 2014 CFR
2014-01-01
... 12 Banks and Banking 1 2014-01-01 2014-01-01 false Purchased credit card relationships, servicing assets, intangible assets (other than purchased credit card relationships and servicing assets), credit... Purchased credit card relationships, servicing assets, intangible assets (other than purchased credit card...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 12 Banks and Banking 1 2013-01-01 2013-01-01 false Purchased credit card relationships, servicing assets, intangible assets (other than purchased credit card relationships and servicing assets), credit... Purchased credit card relationships, servicing assets, intangible assets (other than purchased credit card...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 12 Banks and Banking 6 2013-01-01 2012-01-01 true Purchased credit card relationships, servicing assets, intangible assets (other than purchased credit card relationships and servicing assets), credit... credit card relationships, servicing assets, intangible assets (other than purchased credit card...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 12 Banks and Banking 1 2012-01-01 2012-01-01 false Purchased credit card relationships, servicing assets, intangible assets (other than purchased credit card relationships and servicing assets), credit... Purchased credit card relationships, servicing assets, intangible assets (other than purchased credit card...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 12 Banks and Banking 6 2012-01-01 2012-01-01 false Purchased credit card relationships, servicing assets, intangible assets (other than purchased credit card relationships and servicing assets), credit... credit card relationships, servicing assets, intangible assets (other than purchased credit card...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-25
... savings associations). The OCC requires independent credit card banks and independent credit card Federal... by the bank or Federal savings association. Independent credit card banks and independent credit card... credit card operations and are not affiliated with a full service national bank or Federal savings...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 12 Banks and Banking 6 2014-01-01 2012-01-01 true Purchased credit card relationships, servicing assets, intangible assets (other than purchased credit card relationships and servicing assets), credit... credit card relationships, servicing assets, intangible assets (other than purchased credit card...
Index Nuclear Wallet Cards Contents Current Version Radioactive Nuclides (Homeland Security) Nuclear Materials Management & Safeguards System 8th Edition 2011 Nuclear Wallet Cards Resources Search Nuclear Wallet Cards 8th Edition PDF Format 8thEdition, Android Market Download Nuclear Wallet Cards Nuclear
Evolution of optically nondestructive and data-non-intrusive credit card verifiers
NASA Astrophysics Data System (ADS)
Sumriddetchkajorn, Sarun; Intaravanne, Yuttana
2010-04-01
Since the deployment of the credit card, the number of credit card fraud cases has grown rapidly with a huge amount of loss in millions of US dollars. Instead of asking more information from the credit card's holder or taking risk through payment approval, a nondestructive and data-non-intrusive credit card verifier is highly desirable before transaction begins. In this paper, we review optical techniques that have been proposed and invented in order to make the genuine credit card more distinguishable than the counterfeit credit card. Several optical approaches for the implementation of credit card verifiers are also included. In particular, we highlight our invention on a hyperspectral-imaging based portable credit card verifier structure that offers a very low false error rate of 0.79%. Other key features include low cost, simplicity in design and implementation, no moving part, no need of an additional decoding key, and adaptive learning.
Three dimensional identification card and applications
NASA Astrophysics Data System (ADS)
Zhou, Changhe; Wang, Shaoqing; Li, Chao; Li, Hao; Liu, Zhao
2016-10-01
Three dimensional Identification Card, with its three-dimensional personal image displayed and stored for personal identification, is supposed be the advanced version of the present two-dimensional identification card in the future [1]. Three dimensional Identification Card means that there are three-dimensional optical techniques are used, the personal image on ID card is displayed to be three-dimensional, so we can see three dimensional personal face. The ID card also stores the three-dimensional face information in its inside electronics chip, which might be recorded by using two-channel cameras, and it can be displayed in computer as three-dimensional images for personal identification. Three-dimensional ID card might be one interesting direction to update the present two-dimensional card in the future. Three-dimension ID card might be widely used in airport custom, entrance of hotel, school, university, as passport for on-line banking, registration of on-line game, etc...
Design and implementation of a smart card based healthcare information system.
Kardas, Geylani; Tunali, E Turhan
2006-01-01
Smart cards are used in information technologies as portable integrated devices with data storage and data processing capabilities. As in other fields, smart card use in health systems became popular due to their increased capacity and performance. Their efficient use with easy and fast data access facilities leads to implementation particularly widespread in security systems. In this paper, a smart card based healthcare information system is developed. The system uses smart card for personal identification and transfer of health data and provides data communication via a distributed protocol which is particularly developed for this study. Two smart card software modules are implemented that run on patient and healthcare professional smart cards, respectively. In addition to personal information, general health information about the patient is also loaded to patient smart card. Health care providers use their own smart cards to be authenticated on the system and to access data on patient cards. Encryption keys and digital signature keys stored on smart cards of the system are used for secure and authenticated data communication between clients and database servers over distributed object protocol. System is developed on Java platform by using object oriented architecture and design patterns.
Qin, Haihong; Jin, Jiang; Fischer, Heinz; Mildner, Michael; Gschwandtner, Maria; Mlitz, Veronika; Eckhart, Leopold; Tschachler, Erwin
2017-08-01
CARD18 contains a caspase recruitment domain (CARD) via which it binds to caspase-1 and thereby inhibits caspase-1-mediated activation of the pro-inflammatory cytokine interleukin (IL)-1β. To determine the expression profile and the role of CARD18 during differentiation of keratinocytes and to compare the expression of CARD18 in normal skin and in inflammatory skin diseases. Human keratinocytes were induced to differentiate in monolayer and in 3D skin equivalent cultures. In some experiments, CARD18-specific siRNAs were used to knock down expression of CARD18. CARD18 mRNA levels were determined by quantitative real-time PCR, and CARD18 protein was detected by Western blot and immunofluorescence analyses. In situ expression was analyzed in skin biopsies obtained from healthy donors and patients with psoriasis and lichen planus. CARD18 mRNA was expressed in the epidermis at more than 100-fold higher levels than in any other human tissue. Within the epidermis, CARD18 was specifically expressed in the granular layer. In vitro CARD18 was strongly upregulated at both mRNA and protein levels in keratinocytes undergoing terminal differentiation. In skin equivalent cultures the expression of CARD18 was efficiently suppressed by siRNAs without impairing stratum corneum formation. Epidermal expression of CARD18 was increased after ultraviolet (UV)B irradiation of skin explants. In skin biopsies of patients with psoriasis no consistent regulation of CARD18 expression was observed, however, in lesional epidermis of patients with lichen planus, CARD18 expression was either greatly diminished or entirely absent whereas in non-lesional areas expression was comparable to normal skin. Our results identify CARD18 as a differentiation-associated keratinocyte protein that is altered in abundance by UV stress. Its downregulation in lichen planus indicates a potential role in inflammatory reactions of the epidermis in this disease. Copyright © 2017 Japanese Society for Investigative Dermatology. Published by Elsevier B.V. All rights reserved.
Bohil, Corey J; Higgins, Nicholas A; Keebler, Joseph R
2014-01-01
We compared methods for predicting and understanding the source of confusion errors during military vehicle identification training. Participants completed training to identify main battle tanks. They also completed card-sorting and similarity-rating tasks to express their mental representation of resemblance across the set of training items. We expected participants to selectively attend to a subset of vehicle features during these tasks, and we hypothesised that we could predict identification confusion errors based on the outcomes of the card-sort and similarity-rating tasks. Based on card-sorting results, we were able to predict about 45% of observed identification confusions. Based on multidimensional scaling of the similarity-rating data, we could predict more than 80% of identification confusions. These methods also enabled us to infer the dimensions receiving significant attention from each participant. This understanding of mental representation may be crucial in creating personalised training that directs attention to features that are critical for accurate identification. Participants completed military vehicle identification training and testing, along with card-sorting and similarity-rating tasks. The data enabled us to predict up to 84% of identification confusion errors and to understand the mental representation underlying these errors. These methods have potential to improve training and reduce identification errors leading to fratricide.
Development of the Biology Card Sorting Task to Measure Conceptual Expertise in Biology
Smith, Julia I.; Combs, Elijah D.; Nagami, Paul H.; Alto, Valerie M.; Goh, Henry G.; Gourdet, Muryam A. A.; Hough, Christina M.; Nickell, Ashley E.; Peer, Adrian G.; Coley, John D.; Tanner, Kimberly D.
2013-01-01
There are widespread aspirations to focus undergraduate biology education on teaching students to think conceptually like biologists; however, there is a dearth of assessment tools designed to measure progress from novice to expert biological conceptual thinking. We present the development of a novel assessment tool, the Biology Card Sorting Task, designed to probe how individuals organize their conceptual knowledge of biology. While modeled on tasks from cognitive psychology, this task is unique in its design to test two hypothesized conceptual frameworks for the organization of biological knowledge: 1) a surface feature organization focused on organism type and 2) a deep feature organization focused on fundamental biological concepts. In this initial investigation of the Biology Card Sorting Task, each of six analytical measures showed statistically significant differences when used to compare the card sorting results of putative biological experts (biology faculty) and novices (non–biology major undergraduates). Consistently, biology faculty appeared to sort based on hypothesized deep features, while non–biology majors appeared to sort based on either surface features or nonhypothesized organizational frameworks. Results suggest that this novel task is robust in distinguishing populations of biology experts and biology novices and may be an adaptable tool for tracking emerging biology conceptual expertise. PMID:24297290
A System for the Automatic Assembly of Test Questions Using a No-SQL Database
ERIC Educational Resources Information Center
Shin, Sanggyu; Hashimoto, Hiroshi
2014-01-01
We describe a system that automatically assembles test questions from a set of examples. Our system can create test questions appropriate for each user's level at low cost. In particular, when a user review their lesson, our system provides new test questions which are assembled based on their previous test results and past mistakes, rather than a…
49 CFR 236.587 - Departure test.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.587 Departure test. (a) The automatic train stop, train control, or cab signal apparatus on each locomotive, except a locomotive or a...
ERIC Educational Resources Information Center
JUSTMAN, JOSEPH
CHANGES IN ACADEMIC APTITUDE AND ACHIEVEMENT TEST SCORES OF PUPILS ATTENDING PUBLIC SCHOOLS IN DISADVANTAGED AREAS IN NEW YORK CITY WERE INVESTIGATED. AN ATTEMPT WAS MADE TO DETERMINE WHETHER VARYING DEGREES OF MOBILITY WERE ASSOCIATED WITH VARIATION IN CHANGES IN TEST SCORES. THE CUMULATIVE RECORD CARDS OF SIXTH-GRADE PUPILS WERE EXAMINED TO…
Prechamber Compression-Ignition Engine Performance
NASA Technical Reports Server (NTRS)
Moore, Charles S; Collins, John H , Jr
1938-01-01
Single-cylinder compression-ignition engine tests were made to investigate the performance characteristics of prechamber type of cylinder head. Certain fundamental variables influencing engine performance -- clearance distribution, size, shape, and direction of the passage connecting the cylinder and prechamber, shape of prechamber, cylinder clearance, compression ratio, and boosting -- were independently tested. Results of motoring and of power tests, including several typical indicator cards, are presented.
Acquisition Handbook - Update. Comprehensive Approach to Reusable Defensive Software (CARDS)
1994-03-25
designs, and implementation components (source code, test plans, procedures and results, and system/software documentation). This handbook provides a...activities where software components are acquired, evaluated, tested and sometimes modified. In addition to serving as a facility for the acquisition and...systems from such components [1]. Implementation components are at the lowest level and consist of: specifications; detailed designs; code, test
NASA Technical Reports Server (NTRS)
Barthlome, D. E.
1975-01-01
Test results of a unique automatic brake control system are outlined and a comparison is made of its mode of operation to that of an existing skid control system. The purpose of the test system is to provide automatic control of braking action such that hydraulic brake pressure is maintained at a near constant, optimum value during minimum distance stops.
Riley, Gerard A; Venn, Paul
2015-01-01
Thirty-four participants with acquired brain injury learned word lists under two forms of vanishing cues - one in which the learning trial instructions encouraged intentional retrieval (i.e., explicit memory) and one in which they encouraged automatic retrieval (which encompasses implicit memory). The automatic instructions represented a novel approach in which the cooperation of participants was actively sought to avoid intentional retrieval. Intentional instructions resulted in fewer errors during the learning trials and better performance on immediate and delayed retrieval tests. The advantage of intentional over automatic instructions was generally less for those who had more severe memory and/or executive impairments. Most participants performed better under intentional instructions on both the immediate and the delayed tests. Although those who were more severely impaired in both memory and executive function also did better with intentional instructions on the immediate retrieval test, they were significantly more likely to show an advantage for automatic instructions on the delayed test. It is suggested that this pattern of results may reflect impairments in the consolidation of intentional memories in this group. When using vanishing cues, automatic instructions may be better for those with severe consolidation impairments, but otherwise intentional instructions may be better.
Construction and testing of a simple and economical soil greenhouse gas automatic sampler
Ginting, D.; Arnold, S.L.; Arnold, N.S.; Tubbs, R.S.
2007-01-01
Quantification of soil greenhouse gas emissions requires considerable sampling to account for spatial and/or temporal variation. With manual sampling, additional personnel are often not available to sample multiple sites within a narrow time interval. The objectives were to construct an automatic gas sampler and to compare the accuracy and precision of automatic versus manual sampling. The automatic sampler was tested with carbon dioxide (CO2) fluxes that mimicked the range of CO2 fluxes during a typical corn-growing season in eastern Nebraska. Gas samples were drawn from the chamber at 0, 5, and 10 min manually and with the automatic sampler. The three samples drawn with the automatic sampler were transferred to pre-vacuumed vials after 1 h; thus the samples in syringe barrels stayed connected with the increasing CO2 concentration in the chamber. The automatic sampler sustains accuracy and precision in greenhouse gas sampling while improving time efficiency and reducing labor stress. Copyright ?? Taylor & Francis Group, LLC.
Automatic Collision Avoidance Technology (ACAT)
NASA Technical Reports Server (NTRS)
Swihart, Donald E.; Skoog, Mark A.
2007-01-01
This document represents two views of the Automatic Collision Avoidance Technology (ACAT). One viewgraph presentation reviews the development and system design of Automatic Collision Avoidance Technology (ACAT). Two types of ACAT exist: Automatic Ground Collision Avoidance (AGCAS) and Automatic Air Collision Avoidance (AACAS). The AGCAS Uses Digital Terrain Elevation Data (DTED) for mapping functions, and uses Navigation data to place aircraft on map. It then scans DTED in front of and around aircraft and uses future aircraft trajectory (5g) to provide automatic flyup maneuver when required. The AACAS uses data link to determine position and closing rate. It contains several canned maneuvers to avoid collision. Automatic maneuvers can occur at last instant and both aircraft maneuver when using data link. The system can use sensor in place of data link. The second viewgraph presentation reviews the development of a flight test and an evaluation of the test. A review of the operation and comparison of the AGCAS and a pilot's performance are given. The same review is given for the AACAS is given.
12 CFR 226.12 - Special credit card provisions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Special credit card provisions. 226.12 Section... SYSTEM TRUTH IN LENDING (REGULATION Z) Open-End Credit § 226.12 Special credit card provisions. (a) Issuance of credit cards. Regardless of the purpose for which a credit card is to be used, including...
37 CFR 1.23 - Methods of payment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... made by credit card, except for replenishing a deposit account. Payment of a fee by credit card must specify the amount to be charged to the credit card and such other information as is necessary to process... authorization to charge fees to a credit card. If credit card information is provided on a form or document...