Sample records for automatic transmission fluids

  1. Rolling-element fatigue life with traction fluids and automatic transmission fluid in a high-speed rolling-contact rig

    NASA Technical Reports Server (NTRS)

    Parker, R. J.; Nahm, A. H.; Loewenthal, S. H.

    1982-01-01

    Rolling-element fatigue tests were run in standard and high-speed rolling-contact rigs at bar speeds from 5000 to 50,000 rpm to determine the effects of speed and lubricant film parameter on rolling-element fatigue life. AISI 52100 test bars were tested at a maximum Hertz stress of 4.83 GPa (700,000 psi) with three traction fluids and an automatic transmission fluid. Rolling-element fatigue life increased with speed, with the greatest increases occurring from 10,000 to 50,000 rpm. The life data tended to follow published life-versus-lubricant-film-parameter data up to a film parameter of approximately 3.

  2. Convective Heat Transfer Coefficients of Automatic Transmission Fluid Jets with Implications for Electric Machine Thermal Management: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bennion, Kevin; Moreno, Gilberto

    2015-09-29

    Thermal management for electric machines (motors/ generators) is important as the automotive industry continues to transition to more electrically dominant vehicle propulsion systems. Cooling of the electric machine(s) in some electric vehicle traction drive applications is accomplished by impinging automatic transmission fluid (ATF) jets onto the machine's copper windings. In this study, we provide the results of experiments characterizing the thermal performance of ATF jets on surfaces representative of windings, using Ford's Mercon LV ATF. Experiments were carried out at various ATF temperatures and jet velocities to quantify the influence of these parameters on heat transfer coefficients. Fluid temperatures weremore » varied from 50 degrees C to 90 degrees C to encompass potential operating temperatures within an automotive transaxle environment. The jet nozzle velocities were varied from 0.5 to 10 m/s. The experimental ATF heat transfer coefficient results provided in this report are a useful resource for understanding factors that influence the performance of ATF-based cooling systems for electric machines.« less

  3. Ethylene/acrylic elastomers (EAE): sealing application candidates for the automotive industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carr, J.; Ginn, A.

    1979-01-01

    EAE, based on experimental elastomers developed by Du Pont and called ''Vamac'' (formerly ''MPE''), are ethylene/methyl acrylate copolymers compounded with appropriate plasticizers, fillers, and other additives. They function satisfactorily at -54/sup 0/ to +177/sup 0/C and have excellent tensile strength, elongation, and resistance to compression set, corrosion, tear, and weathering. They show good resistance to automatic transmission fluids, engine oil, some gear lubricants and hydrocarbon greases, water, engine coolants, and dilute acids and bases, but should not be used with gasoline, concentrated acids, high-pressure steam, automotive brake fluids, phosphate ester-based hydraulic fluids, diester-based synthetic lubricants, or chlorinated hydrocarbons. They needmore » no solid-lubricant or antiwear additives, but special mold-release preparations are necessary. They should be useful as seals for the transmission front pump, the clutch, and the engine front crankshaft and possibly for other sealing and nonseal applications (e.g., spark-plug boots).« less

  4. AUTOMOTIVE DIESEL MAINTENANCE 2. UNIT V, AUTOMATIC TRANSMISSIONS--TORQUE CONVERTER.

    ERIC Educational Resources Information Center

    Human Engineering Inst., Cleveland, OH.

    THIS MODULE OF A 25-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OPERATION AND MAINTENANCE OF TORQUE CONVERTERS USED ON DIESEL POWERED VEHICLES. TOPICS ARE (1) FLUID COUPLINGS (LOCATION AND PURPOSE), (2) PRINCIPLES OF OPERATION, (3) TORQUE CONVERRS, (4) TORQMATIC CONVERTER, (5) THREE STAGE, THREE ELEMENT TORQUE CONVERTER, AND (6)…

  5. The use of transmission line modelling to test the effectiveness of I-kaz as autonomous selection of intrinsic mode function

    NASA Astrophysics Data System (ADS)

    Yusop, Hanafi M.; Ghazali, M. F.; Yusof, M. F. M.; PiRemli, M. A.; Karollah, B.; Rusman

    2017-10-01

    Pressure transient signal occurred due to sudden changes in fluid propagation filled in pipelines system, which is caused by rapid pressure and flow fluctuation in a system, such as closing and opening valve rapidly. The application of Hilbert-Huang Transform (HHT) as the method to analyse the pressure transient signal utilised in this research. However, this method has the difficulty in selecting the suitable IMF for the further post-processing, which is Hilbert Transform (HT). This paper proposed the implementation of Integrated Kurtosis-based Algorithm for z-filter Technique (I-kaz) to kurtosis ratio (I-kaz-Kurtosis) for that allows automatic selection of intrinsic mode function (IMF) that’s should be used. This work demonstrated the synthetic pressure transient signal generates using transmission line modelling (TLM) in order to test the effectiveness of I-kaz as the autonomous selection of intrinsic mode function (IMF). A straight fluid network was designed using TLM fixing with higher resistance at some point act as a leak and connecting to the pipe feature (junction, pipefitting or blockage). The analysis results using I-kaz-kurtosis ratio revealed that the method can be utilised as an automatic selection of intrinsic mode function (IMF) although the noise level ratio of the signal is lower. I-kaz-kurtosis ratio is recommended and advised to be implemented as automatic selection of intrinsic mode function (IMF) through HHT analysis.

  6. Automatic fluid dispenser

    NASA Technical Reports Server (NTRS)

    Sakellaris, P. C. (Inventor)

    1977-01-01

    Fluid automatically flows to individual dispensing units at predetermined times from a fluid supply and is available only for a predetermined interval of time after which an automatic control causes the fluid to drain from the individual dispensing units. Fluid deprivation continues until the beginning of a new cycle when the fluid is once again automatically made available at the individual dispensing units.

  7. Automatic Transmissions and Transaxles. Auto Mechanics Curriculum Guide. Module 8. Instructor's Guide.

    ERIC Educational Resources Information Center

    Hevel, David; Tannehill, Dana, Ed.

    This module is the eighth of nine modules in the competency-based Missouri Auto Mechanics Curriculum Guide. Six units cover: introduction to automatic transmission/transaxle; hydraulic control systems; transmission/transaxle diagnosis; automatic transmission/transaxle maintenance and adjustment; in-vehicle transmission repair; and off-car…

  8. Optimization of a pressure control valve for high power automatic transmission considering stability

    NASA Astrophysics Data System (ADS)

    Jian, Hongchao; Wei, Wei; Li, Hongcai; Yan, Qingdong

    2018-02-01

    The pilot-operated electrohydraulic clutch-actuator system is widely utilized by high power automatic transmission because of the demand of large flowrate and the excellent pressure regulating capability. However, a self-excited vibration induced by the inherent non-linear characteristics of valve spool motion coupled with the fluid dynamics can be generated during the working state of hydraulic systems due to inappropriate system parameters, which causes sustaining instability in the system and leads to unexpected performance deterioration and hardware damage. To ensure a stable and fast response performance of the clutch actuator system, an optimal design method for the pressure control valve considering stability is proposed in this paper. A non-linear dynamic model of the clutch actuator system is established based on the motion of the valve spool and coupling fluid dynamics in the system. The stability boundary in the parameter space is obtained by numerical stability analysis. Sensitivity of the stability boundary and output pressure response time corresponding to the valve parameters are identified using design of experiment (DOE) approach. The pressure control valve is optimized using particle swarm optimization (PSO) algorithm with the stability boundary as constraint. The simulation and experimental results reveal that the optimization method proposed in this paper helps in improving the response characteristics while ensuring the stability of the clutch actuator system during the entire gear shift process.

  9. Small passenger car transmission test: Mercury Lynx ATX transmission

    NASA Technical Reports Server (NTRS)

    Bujold, M. P.

    1981-01-01

    The testing of a Mercury Lynx automatic transmission is reported. The transmission was tested in accordance with a passenger car automatic transmission test code (SAE J65lb) which required drive performance, coast performance, and no load test conditions. Under these conditions, the transmission attained maximum efficiencies in the mid-ninety percent range both for drive performance test and coast performance tests. The torque, speed, and efficiency curves are presented, which provide the complete performance characteristics for the Mercury Lynx automatic transmission.

  10. Machine Learning for Characterization of Insect Vector Feeding

    PubMed Central

    Willett, Nora S.; Stelinski, Lukasz L.; Lapointe, Stephen L.

    2016-01-01

    Insects that feed by ingesting plant and animal fluids cause devastating damage to humans, livestock, and agriculture worldwide, primarily by transmitting pathogens of plants and animals. The feeding processes required for successful pathogen transmission by sucking insects can be recorded by monitoring voltage changes across an insect-food source feeding circuit. The output from such monitoring has traditionally been examined manually, a slow and onerous process. We taught a computer program to automatically classify previously described insect feeding patterns involved in transmission of the pathogen causing citrus greening disease. We also show how such analysis contributes to discovery of previously unrecognized feeding states and can be used to characterize plant resistance mechanisms. This advance greatly reduces the time and effort required to analyze insect feeding, and should facilitate developing, screening, and testing of novel intervention strategies to disrupt pathogen transmission affecting agriculture, livestock and human health. PMID:27832081

  11. Equations for Automotive-Transmission Performance

    NASA Technical Reports Server (NTRS)

    Chazanoff, S.; Aston, M. B.; Chapman, C. P.

    1984-01-01

    Curve-fitting procedure ensures high confidence levels. Threedimensional plot represents performance of small automatic transmission coasting in second gear. In equation for plot, PL power loss, S speed and T torque. Equations applicable to manual and automatic transmissions over wide range of speed, torque, and efficiency.

  12. Apparatus enables automatic microanalysis of body fluids

    NASA Technical Reports Server (NTRS)

    Soffen, G. A.; Stuart, J. L.

    1966-01-01

    Apparatus will automatically and quantitatively determine body fluid constituents which are amenable to analysis by fluorometry or colorimetry. The results of the tests are displayed as percentages of full scale deflection on a strip-chart recorder. The apparatus can also be adapted for microanalysis of various other fluids.

  13. Split-personality transmission: shifts like an automatic, saves fuel like a manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, D.

    1981-11-01

    The design, operation and performance of a British-invented automatic transmission which claims to result in fuel economy valves equal to those attained with manual shifts are described. Developed for both 4-speed and 6-speed transmissions, this transmission uses standard parts made for existing manual transmissions, rearranges the gear pairings, and relies on a microcomputer to pick the optimal shift points according to load requirements. (LCL)

  14. Small passenger car transmission test; Ford C4 transmission

    NASA Technical Reports Server (NTRS)

    Bujold, M. P.

    1980-01-01

    A 1979 Ford C4 automatic transmission was tested per a passenger car automatic transmission test code (SAE J651b) which required drive performance, coast performance, and no load test conditions. Under these test conditions, the transmission attained maximum efficiencies in the mid-eighty percent range for both drive performance tests and coast performance tests. The major results of this test (torque, speed, and efficiency curves) are presented. Graphs map the complete performance characteristics for the Ford C4 transmission.

  15. 40 CFR 86.1228-85 - Transmissions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... than one minute in length shall be run with automatic transmissions in “Drive” and the wheels braked..., shall be run in a manner representative of in-use operation, and where appropriate, according to the... and idle modes longer than one minute in length shall be run with automatic transmissions in “Neutral...

  16. [Study on a wireless energy transmission system for the noninvasive examination micro system inside alimentary tracts].

    PubMed

    He, Xiu; Yan, Guo-Zheng; Wang, Fu-Min

    2008-01-01

    A wireless energy transmission system for the MEMS system inside alimentary tracts is reported here in the paper. It consists of an automatic frequency tracking circuit of phase lock loop and phase shift PWM control circuit. Experimental results show that the energy transmission system is capable of automatic frequency-tracking and transmission power-adjusting and has stable received energy.

  17. Optimization of the High-speed On-off Valve of an Automatic Transmission

    NASA Astrophysics Data System (ADS)

    Li-mei, ZHAO; Huai-chao, WU; Lei, ZHAO; Yun-xiang, LONG; Guo-qiao, LI; Shi-hao, TANG

    2018-03-01

    The response time of the high-speed on-off solenoid valve has a great influence on the performance of the automatic transmission. In order to reduce the response time of the high-speed on-off valve, the simulation model of the valve was built by use of AMESim and Ansoft Maxwell softwares. To reduce the response time, an objective function based on ITAE criterion was built and the Genetic Algorithms was used to optimize five parameters including circle number, working air gap, et al. The comparison between experiment and simulation shows that the model is verified. After optimization, the response time of the valve is reduced by 38.16%, the valve can meet the demands of the automatic transmission well. The results can provide theoretical reference for the improvement of automatic transmission performance.

  18. Electric Motor Thermal Management R&D; NREL (National Renewable Energy Laboratory)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bennion, Kevin

    2015-06-09

    Thermal constraints place significant limitations on how electric motors ultimately perform. Without the ability to remove heat, the motor cannot operate without sacrificing performance, efficiency, and reliability. Finite element analysis and computational fluid dynamics modeling approaches are being increasingly utilized in the design and analysis of electric motors. As the models become more sophisticated, it is important to have detailed and accurate knowledge of both the passive thermal performance and the active cooling performance. In this work, we provide an overview of research characterizing both passive and active thermal elements related to electric motor thermal management. To better characterize themore » passive thermal performance, work is being performed to measure motor material thermal properties and thermal contact resistances. The active cooling performance of automatic transmission fluid (ATF) jets is also being measured to better understand the heat transfer coefficients of ATF impinging on motor copper windings.« less

  19. Small passenger car transmission test-Chevrolet 200 transmission

    NASA Technical Reports Server (NTRS)

    Bujold, M. P.

    1980-01-01

    The small passenger car transmission was tested to supply electric vehicle manufacturers with technical information regarding the performance of commerically available transmissions which would enable them to design a more energy efficient vehicle. With this information the manufacturers could estimate vehicle driving range as well as speed and torque requirements for specific road load performance characteristics. A 1979 Chevrolet Model 200 automatic transmission was tested per a passenger car automatic transmission test code (SAE J651b) which required drive performance, coast performance, and no load test conditions. The transmission attained maximum efficiencies in the mid-eighty percent range for both drive performance tests and coast performance tests. Torque, speed and efficiency curves map the complete performance characteristics for Chevrolet Model 200 transmission.

  20. EPA and California Air Resources Board Approve Remedy to Reduce Excess NOx Emissions from Automatic Transmission “Generation 2” 2.0-Liter Diesel Vehicles

    EPA Pesticide Factsheets

    On May 17, 2017, EPA and the California Air Resources Board (CARB) approved an emissions modification proposed by Volkswagen that will reduce NOx emissions from automatic transmission diesel Passats for model years 2012-2014.

  1. AUTOMOTIVE DIESEL MAINTENANCE 2. UNIT VII, AUTOMATIC TRANSMISSIONS--ALLISON, TORQUMATIC SERIES 5960 AND 6060 (PART I).

    ERIC Educational Resources Information Center

    Human Engineering Inst., Cleveland, OH.

    THIS MODULE OF A 25-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OPERATION AND MAINTENANCE OF SPECIFIC MODELS OF AUTOMATIC TRANSMISSIONS USED ON DIESEL POWERED VEHICLES. TOPICS ARE (1) GENERAL SPECIFICATION DATA, (2) OPTIONS FOR VARIOUS APPLICATIONS, (3) ROAD TEST INSTRUCTIONS, (4) IDENTIFICATION AND SPECIFICATION DATA, (5) ALLISON…

  2. AUTOMOTIVE DIESEL MAINTENANCE 2. UNIT X, AUTOMATIC TRANSMISSIONS--HYDRAULIC SYSTEMS (PART II).

    ERIC Educational Resources Information Center

    Human Engineering Inst., Cleveland, OH.

    THIS MODULE OF A 25-MODULE COURSE IS DESIGNED TO PROVIDE A SUMMARY OF MAINTENANCE PROCEDURES FOR AUTOMATIC TRANSMISSIONS USED ON DIESEL POWERED VEHICLES. TOPICS ARE (1) CHECKING THE HYDRAULIC SYSTEM, (2) SERVICING THE HYDRAULIC SYSTEM, (3) EXAMINING THE RANGE CONTROL VALVE, (4) EXAMINING THE LOCK-UP AND FLOW VALVE, (5) EXAMINING THE MAIN REGULATOR…

  3. Sound Transmission through a Cylindrical Sandwich Shell with Honeycomb Core

    NASA Technical Reports Server (NTRS)

    Tang, Yvette Y.; Robinson, Jay H.; Silcox, Richard J.

    1996-01-01

    Sound transmission through an infinite cylindrical sandwich shell is studied in the context of the transmission of airborne sound into aircraft interiors. The cylindrical shell is immersed in fluid media and excited by an oblique incident plane sound wave. The internal and external fluids are different and there is uniform airflow in the external fluid medium. An explicit expression of transmission loss is derived in terms of modal impedance of the fluids and the shell. The results show the effects of (a) the incident angles of the plane wave; (b) the flight conditions of Mach number and altitude of the aircraft; (c) the ratios between the core thickness and the total thickness of the shell; and (d) the structural loss factors on the transmission loss. Comparisons of the transmission loss are made among different shell constructions and different shell theories.

  4. Manual transmission enhances attention and driving performance of ADHD adolescent males: pilot study.

    PubMed

    Cox, Daniel J; Punja, Mohan; Powers, Katie; Merkel, R Lawrence; Burket, Roger; Moore, Melissa; Thorndike, Frances; Kovatchev, Boris

    2006-11-01

    Inattention is a major contributor to driving mishaps and is especially problematic among adolescent drivers with ADHD, possibly contributing to their 2 to 4 times higher incidence of collisions. Manual transmission has been demonstrated to be associated with greater arousal. This study tests the hypotheses that manual transmission, compared to automatic transmission, would be associated with better attention and performance on a driving simulator. Ten adolescent drivers with ADHD practice driving on the simulator in the manual and automatic mode. Employing a single-blind, cross-over design, participants drive the simulator at 19:30 and 22:30 hr for 30 min in both transmissions and rate their attention to driving. Subjectively, participants report being more attentive while driving in manual transmission mode. Objectively, participants drive safer in the manual transmission mode. Although in need of replication, this pilot study suggests a behavioral intervention to improve driving performance among ADHD adolescents.

  5. Investigating the Effect of Advanced Automatic Transmissions of Fuel Consumption Using Vehicle Testing and Modeling (SAE 2016-01-1142)

    EPA Science Inventory

    EPA used the validated ALPHA model to predict the effectiveness improvement of real-world transmissions over a baseline four-speed transmission and to predict further improvements possible from future eight-speed transmissions.

  6. Automatic remote monitoring utilizing daily transmissions: transmission reliability and implantable cardioverter defibrillator battery longevity in the TRUST trial.

    PubMed

    Varma, Niraj; Love, Charles J; Schweikert, Robert; Moll, Philip; Michalski, Justin; Epstein, Andrew E

    2018-04-01

    Benefits of automatic remote home monitoring (HM) among implantable cardioverter defibrillator (ICD) patients may require high transmission frequency. However, transmission reliability and effects on battery longevity remain uncertain. We hypothesized that HM would have high transmission success permitting punctual guideline based follow-up, and improve battery longevity. This was tested in the prospective randomized TRUST trial. Implantable cardioverter defibrillator patients were randomized post-implant 2:1 to HM (n = 908) (transmit daily) or to Conventional in-person monitoring [conventional management (CM), n = 431 (HM disabled)]. In both groups, five evaluations were scheduled every 3 months for 15 months. Home Monitoring technology performance was assessed by transmissions received vs. total possible, and number of scheduled HM checks failing because of missed transmissions. Battery longevity was compared in HM vs. CM at 15 months, and again in HM 3 years post-implant using continuously transmitted data. Transmission success per patient was 91% (median follow-up of 434 days). Overall, daily HM transmissions were received in 315 795 of a potential 363 450 days (87%). Only 55/3759 (1.46%) of unsuccessful scheduled evaluations in HM were attributed to transmission loss. Shock frequency and pacing percentage were similar in HM vs. CM. Fifteen month battery longevity was 12% greater in HM (93.2 ± 8.8% vs. 83.5 ± 6.0% CM, P < 0.001). In extended follow-up of HM patients, estimated battery longevity was 50.9 ± 9.1% (median 52%) at 36 months. Automatic remote HM demonstrated robust transmission reliability. Daily transmission load may be sustained without reducing battery longevity. Home Monitoring conserves battery longevity and tracks long term device performance. ClinicalTrials.gov; NCT00336284.

  7. Environmental Stability and Infectivity of Hepatitis C Virus (HCV) in Different Human Body Fluids.

    PubMed

    Pfaender, Stephanie; Helfritz, Fabian A; Siddharta, Anindya; Todt, Daniel; Behrendt, Patrick; Heyden, Julia; Riebesehl, Nina; Willmann, Wiebke; Steinmann, Joerg; Münch, Jan; Ciesek, Sandra; Steinmann, Eike

    2018-01-01

    Background: Hepatitis C virus (HCV) is a hepatotropic, blood-borne virus, but in up to one-third of infections of the transmission route remained unidentified. Viral genome copies of HCV have been identified in several body fluids, however, non-parental transmission upon exposure to contaminated body fluids seems to be rare. Several body fluids, e.g., tears and saliva, are renowned for their antimicrobial and antiviral properties, nevertheless, HCV stability has never been systematically analyzed in those fluids. Methods: We used state of the art infectious HCV cell culture techniques to investigate the stability of HCV in different body fluids to estimate the potential risk of transmission via patient body fluid material. In addition, we mimicked a potential contamination of HCV in tear fluid and analyzed which impact commercially available contact lens solutions might have in such a scenario. Results: We could demonstrate that HCV remains infectious over several days in body fluids like tears, saliva, semen, and cerebrospinal fluid. Only hydrogen-peroxide contact lens solutions were able to efficiently inactivate HCV in a suspension test. Conclusion: These results indicate that HCV, once it is present in various body fluids of infected patients, remains infective and could potentially contribute to transmission upon direct contact.

  8. Optimal design of an electro-hydraulic valve for heavy-duty vehicle clutch actuator with certain constraints

    NASA Astrophysics Data System (ADS)

    Meng, Fei; Shi, Peng; Karimi, Hamid Reza; Zhang, Hui

    2016-02-01

    The main objective of this paper is to investigate the sensitivity analysis and optimal design of a proportional solenoid valve (PSV) operated pressure reducing valve (PRV) for heavy-duty automatic transmission clutch actuators. The nonlinear electro-hydraulic valve model is developed based on fluid dynamics. In order to implement the sensitivity analysis and optimization for the PRV, the PSV model is validated by comparing the results with data obtained from a real test-bench. The sensitivity of the PSV pressure response with regard to the structural parameters is investigated by using Sobol's method. Finally, simulations and experimental investigations are performed on the optimized prototype and the results reveal that the dynamical characteristics of the valve have been improved in comparison with the original valve.

  9. Electric Motor Thermal Management R&D (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bennion, K.

    2014-11-01

    Thermal constraints place significant limitations on how electric motors ultimately perform. Without the ability to remove heat, the motor cannot operate without sacrificing performance, efficiency, and reliability. Finite element analysis and computational fluid dynamics modeling approaches are being increasingly utilized in the design and analysis of electric motors. As the models become more sophisticated, it is important to have detailed and accurate knowledge of both the passive thermal performance and the active cooling performance. In this work, we provide an overview of research characterizing both passive and active thermal elements related to electric motor thermal management. To better characterize themore » passive thermal performance, the effective thermal properties and inter-lamination thermal contact resistances were measured for different stator lamination materials. The active cooling performance of automatic transmission fluid (ATF) jets was also measured to better understand the heat transfer coefficients of ATF impinging on motor copper windings. Ford's Mercon LV was the ATF evaluated in this study. The presentation provides an overview of prior work with a focus on describing future plans for research to be performed during FY15.« less

  10. Reliability Evaluation of V730 Transmission

    DOT National Transportation Integrated Search

    1982-10-01

    The Detroit Diesel Allison V730 transmission is a heavy duty, automatic, 3-speed, hydraulic transmission, currently installed in full size (35' and 40') transit buses with transverse mounted rear engines. This report presents the general approach and...

  11. Updated Reliability Evaluation of V730 Transmission

    DOT National Transportation Integrated Search

    1983-11-01

    This report culminates a two-year review of factors concerning the reliability of the Detroit Diesel Allison V730 automatic three-speed transmission for urban transit buses. This report is a continuing examination of the transmission's reliability. M...

  12. Investigating the Effect of Advanced Automatic Transmissions ...

    EPA Pesticide Factsheets

    EPA used the validated ALPHA model to predict the effectiveness improvement of real-world transmissions over a baseline four-speed transmission and to predict further improvements possible from future eight-speed transmissions. In preparation for the midterm evaluation (MTE) of the 2017-2025 light-duty GHG emissions rule.

  13. Multibody simulation of vehicles equipped with an automatic transmission

    NASA Astrophysics Data System (ADS)

    Olivier, B.; Kouroussis, G.

    2016-09-01

    Nowadays automotive vehicles remain as one of the most used modes of transportation. Furthermore automatic transmissions are increasingly used to provide a better driving comfort and a potential optimization of the engine performances (by placing the gear shifts at specific engine and vehicle speeds). This paper presents an effective modeling of the vehicle using the multibody methodology (numerically computed under EasyDyn, an open source and in-house library dedicated to multibody simulations). However, the transmission part of the vehicle is described by the usual equations of motion computed using a systematic matrix approach: del Castillo's methodology for planetary gear trains. By coupling the analytic equations of the transmission and the equations computed by the multibody methodology, the performances of any vehicle can be obtained if the characteristics of each element in the vehicle are known. The multibody methodology offers the possibilities to develop the vehicle modeling from 1D-motion to 3D-motion by taking into account the rotations and implementing tire models. The modeling presented in this paper remains very efficient and provides an easy and quick vehicle simulation tool which could be used in order to calibrate the automatic transmission.

  14. Automated manual transmission clutch controller

    DOEpatents

    Lawrie, Robert E.; Reed, Jr., Richard G.; Rausen, David J.

    1999-11-30

    A powertrain system for a hybrid vehicle. The hybrid vehicle includes a heat engine, such as a diesel engine, and an electric machine, which operates as both an electric motor and an alternator, to power the vehicle. The hybrid vehicle also includes a manual-style transmission configured to operate as an automatic transmission from the perspective of the driver. The engine and the electric machine drive an input shaft which in turn drives an output shaft of the transmission. In addition to driving the transmission, the electric machine regulates the speed of the input shaft in order to synchronize the input shaft during either an upshift or downshift of the transmission by either decreasing or increasing the speed of the input shaft. When decreasing the speed of the input shaft, the electric motor functions as an alternator to produce electrical energy which may be stored by a storage device. Operation of the transmission is controlled by a transmission controller which receives input signals and generates output signals to control shift and clutch motors to effect smooth launch, upshift shifts, and downshifts of the transmission, so that the transmission functions substantially as an automatic transmission from the perspective of the driver, while internally substantially functioning as a manual transmission.

  15. Automated manual transmission shift sequence controller

    DOEpatents

    Lawrie, Robert E.; Reed, Richard G.; Rausen, David J.

    2000-02-01

    A powertrain system for a hybrid vehicle. The hybrid vehicle includes a heat engine, such as a diesel engine, and an electric machine, which operates as both, an electric motor and an alternator, to power the vehicle. The hybrid vehicle also includes a manual-style transmission configured to operate as an automatic transmission from the perspective of the driver. The engine and the electric machine drive an input shaft which in turn drives an output shaft of the transmission. In addition to driving the transmission, the electric machine regulates the speed of the input shaft in order to synchronize the input shaft during either an upshift or downshift of the transmission by either decreasing or increasing the speed of the input shaft. When decreasing the speed of the input shaft, the electric motor functions as an alternator to produce electrical energy which may be stored by a storage device. Operation of the transmission is controlled by a transmission controller which receives input signals and generates output signals to control shift and clutch motors to effect smooth launch, upshift shifts, and downshifts of the transmission, so that the transmission functions substantially as an automatic transmission from the perspective of the driver, while internally substantially functioning as a manual transmission.

  16. Automated manual transmission mode selection controller

    DOEpatents

    Lawrie, Robert E.

    1999-11-09

    A powertrain system for a hybrid vehicle. The hybrid vehicle includes a heat engine, such as a diesel engine, and an electric machine, which operates as both an electric motor and an alternator, to power the vehicle. The hybrid vehicle also includes a manual-style transmission configured to operate as an automatic transmission from the perspective of the driver. The engine and the electric machine drive an input shaft which in turn drives an output shaft of the transmission. In addition to driving the transmission, the electric machine regulates the speed of the input shaft in order to synchronize the input shaft during either an upshift or downshift of the transmission by either decreasing or increasing the speed of the input shaft. When decreasing the speed of the input shaft, the electric motor functions as an alternator to produce electrical energy which may be stored by a storage device. Operation of the transmission is controlled by a transmission controller which receives input signals and generates output signals to control shift and clutch motors to effect smooth launch, upshift shifts, and downshifts of the transmission, so that the transmission functions substantially as an automatic transmission from the perspective of the driver, while internally substantially functioning as a manual transmission.

  17. Automated manual transmission controller

    DOEpatents

    Lawrie, Robert E.; Reed, Jr., Richard G.; Bernier, David R.

    1999-12-28

    A powertrain system for a hybrid vehicle. The hybrid vehicle includes a heat engine, such as a diesel engine, and an electric machine, which operates as both an electric motor and an alternator, to power the vehicle. The hybrid vehicle also includes a manual-style transmission configured to operate as an automatic transmission from the perspective of the driver. The engine and the electric machine drive an input shaft which in turn drives an output shaft of the transmission. In addition to driving the transmission, the electric machine regulates the speed of the input shaft in order to synchronize the input shaft during either an upshift or downshift of the transmission by either decreasing or increasing the speed of the input shaft. When decreasing the speed of the input shaft, the electric motor functions as an alternator to produce electrical energy which may be stored by a storage device. Operation of the transmission is controlled by a transmission controller which receives input signals and generates output signals to control shift and clutch motors to effect smooth launch, upshift shifts, and downshifts of the transmission, so that the transmission functions substantially as an automatic transmission from the perspective of the driver, while internally substantially functioning as a manual transmission.

  18. Automatic amino acid analyzer

    NASA Technical Reports Server (NTRS)

    Berdahl, B. J.; Carle, G. C.; Oyama, V. I.

    1971-01-01

    Analyzer operates unattended or up to 15 hours. It has an automatic sample injection system and can be programmed. All fluid-flow valve switching is accomplished pneumatically from miniature three-way solenoid pilot valves.

  19. Drive-By-Wire Technology

    DTIC Science & Technology

    2001-05-29

    Symposium Intelligent Systems for the Objective Fleet uTransmission controls uSteering (both on-transmission and under-carriage) uBraking (service and...parking) uTransmission select uThrottle uOther Electromechanical Opportunities uTurret drives (elevation, traverse) uAutomatic propellant handling systems

  20. Radio frequency power load and associated method

    NASA Technical Reports Server (NTRS)

    Sims, III, William Herbert (Inventor); Chavers, Donald Gregory (Inventor); Richeson, James J. (Inventor)

    2010-01-01

    A radio frequency power load and associated method. A radio frequency power load apparatus includes a container and a fluid having an ion source therein, the fluid being contained in the container. Two conductors are immersed in the fluid. A radio frequency transmission system includes a radio frequency transmitter, a radio frequency amplifier connected to the transmitter and a radio frequency power load apparatus connected to the amplifier. The apparatus includes a fluid having an ion source therein, and two conductors immersed in the fluid. A method of dissipating power generated by a radio frequency transmission system includes the steps of: immersing two conductors of a radio frequency power load apparatus in a fluid having an ion source therein; and connecting the apparatus to an amplifier of the transmission system.

  1. 46 CFR 61.30-20 - Automatic control and safety tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Automatic control and safety tests. 61.30-20 Section 61... TESTS AND INSPECTIONS Tests and Inspections of Fired Thermal Fluid Heaters § 61.30-20 Automatic control and safety tests. Operational tests and checks of all safety and limit controls, combustion controls...

  2. Automatic partitioning of unstructured meshes for the parallel solution of problems in computational mechanics

    NASA Technical Reports Server (NTRS)

    Farhat, Charbel; Lesoinne, Michel

    1993-01-01

    Most of the recently proposed computational methods for solving partial differential equations on multiprocessor architectures stem from the 'divide and conquer' paradigm and involve some form of domain decomposition. For those methods which also require grids of points or patches of elements, it is often necessary to explicitly partition the underlying mesh, especially when working with local memory parallel processors. In this paper, a family of cost-effective algorithms for the automatic partitioning of arbitrary two- and three-dimensional finite element and finite difference meshes is presented and discussed in view of a domain decomposed solution procedure and parallel processing. The influence of the algorithmic aspects of a solution method (implicit/explicit computations), and the architectural specifics of a multiprocessor (SIMD/MIMD, startup/transmission time), on the design of a mesh partitioning algorithm are discussed. The impact of the partitioning strategy on load balancing, operation count, operator conditioning, rate of convergence and processor mapping is also addressed. Finally, the proposed mesh decomposition algorithms are demonstrated with realistic examples of finite element, finite volume, and finite difference meshes associated with the parallel solution of solid and fluid mechanics problems on the iPSC/2 and iPSC/860 multiprocessors.

  3. Capacitive system detects and locates fluid leaks

    NASA Technical Reports Server (NTRS)

    1966-01-01

    Electronic monitoring system automatically detects and locates minute leaks in seams of large fluid storage tanks and pipelines covered with thermal insulation. The system uses a capacitive tape-sensing element that is adhesively bonded over seams where fluid leaks are likely to occur.

  4. 49 CFR 571.102 - Standard No. 102; Transmission shift position sequence, starter interlock, and transmission...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... position. S3.1.2Transmission braking effect. In vehicles having more than one forward transmission gear... driver has activated the vehicle's propulsion system: (a) The engine may stop and restart automatically... activated the vehicle's propulsion system if the vehicle can meet the requirements specified in paragraphs...

  5. Research on Application of Automatic Weather Station Based on Internet of Things

    NASA Astrophysics Data System (ADS)

    Jianyun, Chen; Yunfan, Sun; Chunyan, Lin

    2017-12-01

    In this paper, the Internet of Things is briefly introduced, and then its application in the weather station is studied. A method of data acquisition and transmission based on NB-iot communication mode is proposed, Introduction of Internet of things technology, Sensor digital and independent power supply as the technical basis, In the construction of Automatic To realize the intelligent interconnection of the automatic weather station, and then to form an automatic weather station based on the Internet of things. A network structure of automatic weather station based on Internet of things technology is constructed to realize the independent operation of intelligent sensors and wireless data transmission. Research on networking data collection and dissemination of meteorological data, through the data platform for data analysis, the preliminary work of meteorological information publishing standards, networking of meteorological information receiving terminal provides the data interface, to the wisdom of the city, the wisdom of the purpose of the meteorological service.

  6. Kickdown control for a motor vehicle automatic transmission with two stage kickdown

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Higashi, H.; Waki, K.; Fukuiri, M.

    This patent describes a vehicle automatic transmission. This transmission consists of a hydraulic torque converter, a transmission gear mechanism connected with the torque converter and has at least three gear stages of different gear ratios for foward drive, friction for selecting one of the gear stages. A kick down control which consists of a first shift down circuit for controlling the friction so that the transmission gear mechanism is shifted down from a high gear stage to a lower gear stage. A kick down solenoid is provided in the first shift down circuit for controlling the first shift down circuitmore » and a kick down switch is adapted to be actuated by an engine control member. When the engine control member is moved substantially to a full power position to thereby control the kick down solenoid effects a shift down from a high gear stage to a lower gear stage.« less

  7. 46 CFR 61.30-20 - Automatic control and safety tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Automatic control and safety tests. 61.30-20 Section 61.30-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND INSPECTIONS Tests and Inspections of Fired Thermal Fluid Heaters § 61.30-20 Automatic control and safety tests. Operational tests and check...

  8. Universal penetration test apparatus with fluid penetration sensor

    DOEpatents

    Johnson, Phillip W.; Stampfer, Joseph F.; Bradley, Orvil D.

    1999-01-01

    A universal penetration test apparatus for measuring resistance of a material to a challenge fluid. The apparatus includes a pad saturated with the challenge fluid. The apparatus includes a compression assembly for compressing the material between the pad and a compression member. The apparatus also includes a sensor mechanism for automatically detecting when the challenge fluid penetrates the material.

  9. Small passenger car transmission test: Dodge Omni A-404 transmission

    NASA Technical Reports Server (NTRS)

    Bujold, M. P.

    1980-01-01

    The small passenger car transmission test was initiated to supply electric vehicle manufacturers with technical information regarding the performance of commercially available transmissions. This transmission was tested in accordance with a passenger car automatic transmission test code (SAE J65lb) which required drive performance, coast performance, and no load test conditions. Under these test conditions, the transmission attained maximum efficiencies in the mid eighty percent range for both drive performance test and coast performance tests.

  10. Radio Frequency Power Load and Associated Method

    NASA Technical Reports Server (NTRS)

    Srinivasan, V. Karthik (Inventor); Freestone, Todd M. (Inventor); Sims, William Herbert, III (Inventor)

    2014-01-01

    A radio frequency power load and associated method. A radio frequency power load apparatus may include a container with an ionized fluid therein. The apparatus may include one conductor immersed in a fluid and another conductor electrically connected to the container. A radio frequency transmission system may include a radio frequency transmitter, a radio frequency amplifier connected to the transmitter and a radio frequency power load apparatus connected to the amplifier. The apparatus may include a fluid having an ion source therein, one conductor immersed in a fluid, and another conductor electrically connected to the container. A method of dissipating power generated by a radio frequency transmission system may include constructing a waveguide with ionized fluid in a container and connecting the waveguide to an amplifier of the transmission system.

  11. Testing and Benchmarking a 2014 GM Silverado 6L80 Six Speed Automatic Transmission

    EPA Science Inventory

    Describe the method and test results of EPA’s partial transmission benchmarking process which involves installing both the engine and transmission in an engine dynamometer test cell with the engine wire harness tethered to its vehicle parked outside the test cell.

  12. 40 CFR 86.128-79 - Transmissions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., shall be run according to the manufacturer's recommendations to the ultimate purchaser, Provided, That... recommendations to the ultimate purchaser. (c) Idle modes less than one minute in length shall be run with automatic transmissions in “Drive” and the wheels braked; manual transmissions shall be in gear with the...

  13. System and technique for ultrasonic determination of degree of cooking

    DOEpatents

    Bond, Leonard J [Richland, WA; Diaz, Aaron A [W. Richland, WA; Judd, Kayte M [Richland, WA; Pappas, Richard A [Richland, WA; Cliff, William C [Richland, WA; Pfund, David M [Richland, WA; Morgen, Gerald P [Kennewick, WA

    2007-03-20

    A method and apparatus are described for determining the doneness of food during a cooking process. Ultrasonic signal are passed through the food during cooking. The change in transmission characteristics of the ultrasonic signal during the cooking process is measured to determine the point at which the food has been cooked to the proper level. In one aspect, a heated fluid cooks the food, and the transmission characteristics along a fluid-only ultrasonic path provides a reference for comparison with the transmission characteristics for a food-fluid ultrasonic path.

  14. Universal penetration test apparatus with fluid penetration sensor

    DOEpatents

    Johnson, P.W.; Stampfer, J.F.; Bradley, O.D.

    1999-02-02

    A universal penetration test apparatus is described for measuring resistance of a material to a challenge fluid. The apparatus includes a pad saturated with the challenge fluid. The apparatus includes a compression assembly for compressing the material between the pad and a compression member. The apparatus also includes a sensor mechanism for automatically detecting when the challenge fluid penetrates the material. 23 figs.

  15. Influence of Normal and Shear Stress on the Hydraulic Transmissivity of Thin Cracks in a Tight Quartz Sandstone, a Granite, and a Shale

    NASA Astrophysics Data System (ADS)

    Rutter, Ernest H.; Mecklenburgh, Julian

    2018-02-01

    Transmissivity of fluids along fractures in rocks is reduced by increasing normal stress acting across them, demonstrated here through gas flow experiments on Bowland shale, and oil flow experiments on Pennant sandstone and Westerly granite. Additionally, the effect of imposing shear stress at constant normal stress was determined, until frictional sliding started. In all cases, increasing shear stress causes an accelerating reduction of transmissivity by 1 to 3 orders of magnitude as slip initiated, as a result of the formation of wear products that block fluid pathways. Only in the case of granite, and to a lesser extent in the sandstone, was there a minor amount of initial increase of transmissivity prior to the onset of slip. These results cast into doubt the commonly applied presumption that cracks with high resolved shear stresses are the most conductive. In the shale, crack transmissivity is commensurate with matrix permeability, such that shales are expected always to be good seals. For the sandstone and granite, unsheared crack transmissivity was respectively 2 and 2.5 orders of magnitude greater than matrix permeability. For these rocks crack transmissivity can dominate fluid flow in the upper crust, potentially enough to permit maintenance of a hydrostatic fluid pressure gradient in a normal (extensional) faulting regime.

  16. Automobile windshield washer fluid: A potential source of transmission for Legionella.

    PubMed

    Schwake, David Otto; Alum, Absar; Abbaszadegan, Morteza

    2015-09-01

    Epidemiological evidence suggesting driving cars to be a risk factor for legionellosis has prompted public health studies to investigate vehicle windshield washer fluid as a novel transmission source of this disease. The goal of the current study was to investigate whether or not windshield washer fluid could serve as a potential source of transmission for Legionella. A wide variation in the survival of L. pneumophila was observed when incubated in different washer fluids at 25 and 37 °C, however, one brand tested supported Legionella survival similar to or greater than sterilized deionized water. In addition, 1 L of tap water contained in a washer fluid reservoir was able to support population growth and survival of Legionella for several months. In a field study examining the windshield washer fluid of 12 elementary school buses, Legionella were detected from 84% of samples at a high concentration of 8.1×10(4) CFU/mL. Culturable cells were also detected in aerosolized washer fluid during washer fluid spray. By demonstrating survival in certain windshield washer fluids, growth within washer fluid reservoirs, and the presence of viable cells in bus washer fluid spray, we have provided evidence suggesting the potential for a novel route of Legionella exposure. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Self-filling and self-purging apparatus for detecting spontaneous radiation from substances in fluids

    DOEpatents

    Larson, I. Lauren; Chiles, Marion M.; Miller, V. Clint

    1993-01-01

    Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.

  18. A practical tool for estimating subsurface LNAPL distributions and transmissivity using current and historical fluid levels in groundwater wells: Effects of entrapped and residual LNAPL

    NASA Astrophysics Data System (ADS)

    Lenhard, R. J.; Rayner, J. L.; Davis, G. B.

    2017-10-01

    A model is presented to account for elevation-dependent residual and entrapped LNAPL above and below, respectively, the water-saturated zone when predicting subsurface LNAPL specific volume (fluid volume per unit area) and transmissivity from current and historic fluid levels in wells. Physically-based free, residual, and entrapped LNAPL saturation distributions and LNAPL relative permeabilities are integrated over a vertical slice of the subsurface to yield the LNAPL specific volumes and transmissivity. The model accounts for effects of fluctuating water tables. Hypothetical predictions are given for different porous media (loamy sand and clay loam), fluid levels in wells, and historic water-table fluctuations. It is shown the elevation range from the LNAPL-water interface in a well to the upper elevation where the free LNAPL saturation approaches zero is the same for a given LNAPL thickness in a well regardless of porous media type. Further, the LNAPL transmissivity is largely dependent on current fluid levels in wells and not historic levels. Results from the model can aid developing successful LNAPL remediation strategies and improving the design and operation of remedial activities. Results of the model also can aid in accessing the LNAPL recovery technology endpoint, based on the predicted transmissivity.

  19. Small passenger car transmission test; Chevrolet LUV transmission

    NASA Technical Reports Server (NTRS)

    Bujold, M. P.

    1980-01-01

    A 1978 Chevrolet LUV manual transmission tested per the applicable portions of a passenger car automatic transmission test code (SAE J65lb) which required drive performance, coast performance, and no load test conditions. Under these test conditions, the transmission attained maximum efficiencies in the upper ninety percent range for both drive performance tests and coast performance tests. The major results of this test (torque, speed, and efficiency curves) are presented. Graphs map the complete performance characteristics for the Chevrolet LUV transmission.

  20. Design of synchromesh mechanism to optimization manual transmission's electric vehicle

    NASA Astrophysics Data System (ADS)

    Zainuri, Fuad; Sumarsono, Danardono A.; Adhitya, Muhammad; Siregar, Rolan

    2017-03-01

    Significant research has been attempted on a vehicle that lead to the development of transmission that can reduce energy consumption and improve vehicle efficiency. Consumers also expect safety, convenience, and competitive prices. Automatic transmission (AT), continuously variable transmission (CVT), and dual clutch transmission (DCT) is the latest transmission developed for road vehicle. From literature reviews that have been done that this transmission is less effective on electric cars which use batteries as a power source compared to type manual transmission, this is due to the large power losses when making gear changes. Zeroshift system is the transmission can do shift gears with no time (zero time). It was developed for the automatic manual transmission, and this transmission has been used on racing vehicles to eliminate deceleration when gear shift. Zeroshift transmission still use the clutch to change gear in which electromechanical be used to replace the clutch pedal. Therefore, the transmission is too complex for the transmission of electric vehicles, but its mechanism is considered very suitable to increase the transmission efficiency. From this idea, a new innovation design transmission will be created to electric car. The combination synchromesh with zeroshift mechanism for the manual transmission is a transmission that is ideal for improving the transmission efficiency. Installation synchromesh on zeroshift mechanism is expected to replace the function of the clutch MT, and assisted with the motor torque setting when to change gear. Additionally to consider is the weight of the transmission, ease of manufacturing, ease of installation with an electric motor, as well as ease of use by drivers is a matter that must be done to obtain a new transmission system that is suitable for electric cars.

  1. Spool-type control valve assembly with reduced spool stroke for hydraulic belt-and-pulley type continuously variable transmission

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Itoh, H.; Akashi, T.; Takada, M.

    1987-03-31

    This patent describes a hydraulic control system for controlling a speed ratio of a hydraulically-operated continuously variable transmission of belt-and-pulley type having a variable-diameter pulley and a hydraulic cylinder for changing an effective diameter of the variable diameter-pulley of the transmission. The hydraulic control system includes a speed-ratio control valve assembly for controlling the supply and discharge of a pressurized fluid to and from the hydraulic cylinder to thereby change the speed ratio of the transmission. The speed-ratio control valve assembly comprises: a shift-direction switching valve unit disposed in fluid supply and discharge conduits communicating with the hydraulic cylinder, formore » controlling a direction in which the speed ratio of the transmission is varied; a shift-speed control valve unit of spool-valve type connected to the shift-direction switching valve unit. The shift-speed control valve unit is selectively placed in a first state in which the fluid supply and discharge flows to and from the hydraulic cylinder through the conduits are permitted, or in a second state in which the fluid supply flow is restricted while the fluid discharge flow is inhibited; an actuator means for placing the shift speed control valve unit alternately in the first and second states to control a rate of variation in the speed ratio of the transmission in the direction established by the shift-direction switching valve unit.« less

  2. Improved diffusing wave spectroscopy based on the automatized determination of the optical transport and absorption mean free path

    NASA Astrophysics Data System (ADS)

    Zhang, Chi; Reufer, Mathias; Gaudino, Danila; Scheffold, Frank

    2017-11-01

    Diffusing wave spectroscopy (DWS) can be employed as an optical rheology tool with numerous applications for studying the structure, dynamics and linear viscoelastic properties of complex fluids, foams, glasses and gels. To carry out DWS measurements, one first needs to quantify the static optical properties of the sample under investigation, i.e. the transport mean free path l * and the absorption length l a. In the absence of absorption this can be done by comparing the diffuse optical transmission to a calibration sample whose l * is known. Performing this comparison however is cumbersome, time consuming, and prone to mistakes by the operator. Moreover, already weak absorption can lead to significant errors. In this paper, we demonstrate the implementation of an automatized approach, based on which the DWS measurement procedure can be simplified significantly. By comparison with a comprehensive set of calibration measurements we cover the entire parameter space relating measured count rates ( CR t , CR b ) to ( l *, l a). Based on this approach we can determine l * and la of an unknown sample accurately thus making the additional measurement of a calibration sample obsolete. We illustrate the use of this approach by monitoring the coarsening of a commercially available shaving foam with DWS.

  3. Ebola Virus Shedding and Transmission: Review of Current Evidence.

    PubMed

    Vetter, Pauline; Fischer, William A; Schibler, Manuel; Jacobs, Michael; Bausch, Daniel G; Kaiser, Laurent

    2016-10-15

     The magnitude of the 2013-2016 Ebola virus disease outbreak in West Africa was unprecedented, with >28 500 reported cases and >11 000 deaths. Understanding the key elements of Ebola virus transmission is necessary to implement adequate infection prevention and control measures to protect healthcare workers and halt transmission in the community.  We performed an extensive PubMed literature review encompassing the period from discovery of Ebola virus, in 1976, until 1 June 2016 to evaluate the evidence on modes of Ebola virus shedding and transmission.  Ebola virus has been isolated by cell culture from blood, saliva, urine, aqueous humor, semen, and breast milk from infected or convalescent patients. Ebola virus RNA has been noted in the following body fluids days or months after onset of illness: saliva (22 days), conjunctiva/tears (28 days), stool (29 days), vaginal fluid (33 days), sweat (44 days), urine (64 days), amniotic fluid (38 days), aqueous humor (101 days), cerebrospinal fluid (9 months), breast milk (16 months [preliminary data]), and semen (18 months). Nevertheless, the only documented cases of secondary transmission from recovered patients have been through sexual transmission. We did not find strong evidence supporting respiratory or fomite-associated transmission. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  4. Are self-reported telemonitored blood pressure readings affected by end-digit preference: a prospective cohort study in Scotland.

    PubMed

    Parker, Richard A; Paterson, Mary; Padfield, Paul; Pinnock, Hilary; Hanley, Janet; Hammersley, Vicky S; Steventon, Adam; McKinstry, Brian

    2018-01-31

    Simple forms of blood pressure (BP) telemonitoring require patients to text readings to central servers creating an opportunity for both entry error and manipulation. We wished to determine if there was an apparent preference for particular end digits and entries which were just below target BPs which might suggest evidence of data manipulation. Prospective cohort study SETTING: 37 socioeconomically diverse primary care practices from South East Scotland. Patients were recruited with hypertension to a telemonitoring service in which patients submitted home BP readings by manually transcribing the measurements into text messages for transmission ('patient-texted system'). These readings were compared with those from primary care patients with uncontrolled hypertension using a system in which readings were automatically transmitted, eliminating the possibility of manipulation of values ('automatic-transmission system'). A generalised estimating equations method was used to compare BP readings between the patient-texted and automatic-transmission systems, while taking into account clustering of readings within patients. A total of 44 150 BP readings were analysed on 1068 patients using the patient-texted system compared with 20 705 readings on 199 patients using the automatic-transmission system. Compared with the automatic-transmission data, the patient-texted data showed a significantly higher proportion of occurrences of both systolic and diastolic BP having a zero end digit (OR 2.1, 95% CI 1.7 to 2.6) although incidence was <2% of readings. Similarly, there was a preference for systolic 134 and diastolic 84 (the threshold for alerts was 135/85) (134 systolic BP OR 1.5, 95% CI 1.3 to 1.8; 84 diastolic BP OR 1.5, 95% CI 1.3 to 1.9). End-digit preference for zero numbers and specific-value preference for readings just below the alert threshold exist among patients in self-reporting their BP using telemonitoring. However, the proportion of readings affected is small and unlikely to be clinically important. ISRCTN72614272; Post-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. 2D Automatic body-fitted structured mesh generation using advancing extraction method

    USDA-ARS?s Scientific Manuscript database

    This paper presents an automatic mesh generation algorithm for body-fitted structured meshes in Computational Fluids Dynamics (CFD) analysis using the Advancing Extraction Method (AEM). The method is applicable to two-dimensional domains with complex geometries, which have the hierarchical tree-like...

  6. 2D automatic body-fitted structured mesh generation using advancing extraction method

    USDA-ARS?s Scientific Manuscript database

    This paper presents an automatic mesh generation algorithm for body-fitted structured meshes in Computational Fluids Dynamics (CFD) analysis using the Advancing Extraction Method (AEM). The method is applicable to two-dimensional domains with complex geometries, which have the hierarchical tree-like...

  7. Continuous variable transmission and regenerative braking devices in bicycles utilizing magnetorheological fluids

    NASA Astrophysics Data System (ADS)

    Cheung, Wai Ming; Liao, Wei-Hsin

    2013-04-01

    The use of magnetorheological (MR) fluids in vehicles has been gaining popular recently due to its controllable nature, which gives automotive designers more dimensions of freedom in functional designs. However, not much attention has been paid to apply it to bicycles. This paper is aimed to study the feasibility of applying MR fluids in different dynamic parts of a bicycle such as the transmission and braking systems. MR continuous variable transmission (CVT) and power generator assisted in braking systems were designed and analyzed. Both prototypes were fabricated and tested to evaluate their performances. Experimental results showed that the proposed designs are promising to be used in bicycles.

  8. A practical tool for estimating subsurface LNAPL distributions and transmissivity using current and historical fluid levels in groundwater wells: Effects of entrapped and residual LNAPL.

    PubMed

    Lenhard, R J; Rayner, J L; Davis, G B

    2017-10-01

    A model is presented to account for elevation-dependent residual and entrapped LNAPL above and below, respectively, the water-saturated zone when predicting subsurface LNAPL specific volume (fluid volume per unit area) and transmissivity from current and historic fluid levels in wells. Physically-based free, residual, and entrapped LNAPL saturation distributions and LNAPL relative permeabilities are integrated over a vertical slice of the subsurface to yield the LNAPL specific volumes and transmissivity. The model accounts for effects of fluctuating water tables. Hypothetical predictions are given for different porous media (loamy sand and clay loam), fluid levels in wells, and historic water-table fluctuations. It is shown the elevation range from the LNAPL-water interface in a well to the upper elevation where the free LNAPL saturation approaches zero is the same for a given LNAPL thickness in a well regardless of porous media type. Further, the LNAPL transmissivity is largely dependent on current fluid levels in wells and not historic levels. Results from the model can aid developing successful LNAPL remediation strategies and improving the design and operation of remedial activities. Results of the model also can aid in accessing the LNAPL recovery technology endpoint, based on the predicted transmissivity. Copyright © 2017 Commonwealth Scientific and Industrial Research Organisation - Copyright 2017. Published by Elsevier B.V. All rights reserved.

  9. Computer program MCAP-TOSS calculates steady-state fluid dynamics of coolant in parallel channels and temperature distribution in surrounding heat-generating solid

    NASA Technical Reports Server (NTRS)

    Lee, A. Y.

    1967-01-01

    Computer program calculates the steady state fluid distribution, temperature rise, and pressure drop of a coolant, the material temperature distribution of a heat generating solid, and the heat flux distributions at the fluid-solid interfaces. It performs the necessary iterations automatically within the computer, in one machine run.

  10. Automatic patient respiration failure detection system with wireless transmission

    NASA Technical Reports Server (NTRS)

    Dimeff, J.; Pope, J. M.

    1968-01-01

    Automatic respiration failure detection system detects respiration failure in patients with a surgically implanted tracheostomy tube, and actuates an audible and/or visual alarm. The system incorporates a miniature radio transmitter so that the patient is unencumbered by wires yet can be monitored from a remote location.

  11. Towards an automatic lab-on-valve-ion mobility spectrometric system for detection of cocaine abuse.

    PubMed

    Cocovi-Solberg, David J; Esteve-Turrillas, Francesc A; Armenta, Sergio; de la Guardia, Miguel; Miró, Manuel

    2017-08-25

    A lab-on-valve miniaturized system integrating on-line disposable micro-solid phase extraction has been interfaced with ion mobility spectrometry for the accurate and sensitive determination of cocaine and ecgonine methyl ester in oral fluids. The method is based on the automatic loading of 500μL of oral fluid along with the retention of target analytes and matrix clean-up by mixed-mode cationic/reversed-phase solid phase beads, followed by elution with 100μL of 2-propanol containing (3% v/v) ammonia, which are online injected into the IMS. The sorptive particles are automatically discarded after every individual assay inasmuch as the sorptive capacity of the sorbent material is proven to be dramatically deteriorated with reuse. The method provided a limit of detection of 0.3 and 0.14μgL -1 for cocaine and ecgonine methyl ester, respectively, with relative standard deviation values from 8 till 14% with a total analysis time per sample of 7.5min. Method trueness was evaluated by analyzing oral fluid samples spiked with cocaine at different concentration levels (1, 5 and 25μgL -1 ) affording relative recoveries within the range of 85±24%. Fifteen saliva samples were collected from volunteers and analysed following the proposed automatic procedure, showing a 40% cocaine occurrence with concentrations ranging from 1.3 to 97μgL -1 . Field saliva samples were also analysed by reference methods based on lateral flow immunoassay and gas chromatography-mass spectrometry. The application of this procedure to the control of oral fluids of cocaine consumers represents a step forward towards the development of a point-of-care cocaine abuse sensing system. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Computer controlled synchronous shifting of an automatic transmission

    DOEpatents

    Davis, Roy I.; Patil, Prabhakar B.

    1989-01-01

    A multiple forward speed automatic transmission produces its lowest forward speed ratio when a hydraulic clutch and hydraulic brake are disengaged and a one-way clutch connects a ring gear to the transmission casing. Second forward speed ratio results when the hydraulic clutch is engaged to connect the ring gear to the planetary carrier of a second gear set. Reverse drive and regenerative operation result when an hydraulic brake fixes the planetary and the direction of power flow is reversed. Various sensors produce signals representing the torque at the output of the transmission or drive wheels, the speed of the power source, and the hydraulic pressure applied to a clutch and brake. A control algorithm produces input data representing a commanded upshift, a commanded downshift, a commanded transmission output torque, and commanded power source speed. A microprocessor processes the inputs and produces a response to them in accordance with the execution of a control algorithm. Output or response signals cause selective engagement and disengagement of the clutch and brake at a rate that satisfies the requirements for a short gear ratio change and smooth torque transfer between the friction elements.

  13. Method for automatically scramming a nuclear reactor

    DOEpatents

    Ougouag, Abderrafi M.; Schultz, Richard R.; Terry, William K.

    2005-12-27

    An automatically scramming nuclear reactor system. One embodiment comprises a core having a coolant inlet end and a coolant outlet end. A cooling system operatively associated with the core provides coolant to the coolant inlet end and removes heated coolant from the coolant outlet end, thus maintaining a pressure differential therebetween during a normal operating condition of the nuclear reactor system. A guide tube is positioned within the core with a first end of the guide tube in fluid communication with the coolant inlet end of the core, and a second end of the guide tube in fluid communication with the coolant outlet end of the core. A control element is positioned within the guide tube and is movable therein between upper and lower positions, and automatically falls under the action of gravity to the lower position when the pressure differential drops below a safe pressure differential.

  14. A procedure for automating CFD simulations of an inlet-bleed problem

    NASA Technical Reports Server (NTRS)

    Chyu, Wei J.; Rimlinger, Mark J.; Shih, Tom I.-P.

    1995-01-01

    A procedure was developed to improve the turn-around time for computational fluid dynamics (CFD) simulations of an inlet-bleed problem involving oblique shock-wave/boundary-layer interactions on a flat plate with bleed into a plenum through one or more circular holes. This procedure is embodied in a preprocessor called AUTOMAT. With AUTOMAT, once data for the geometry and flow conditions have been specified (either interactively or via a namelist), it will automatically generate all input files needed to perform a three-dimensional Navier-Stokes simulation of the prescribed inlet-bleed problem by using the PEGASUS and OVERFLOW codes. The input files automatically generated by AUTOMAT include those for the grid system and those for the initial and boundary conditions. The grid systems automatically generated by AUTOMAT are multi-block structured grids of the overlapping type. Results obtained by using AUTOMAT are presented to illustrate its capability.

  15. Microfluidic on-chip fluorescence-activated interface control system

    PubMed Central

    Haiwang, Li; Nguyen, N. T.; Wong, T. N.; Ng, S. L.

    2010-01-01

    A microfluidic dynamic fluorescence-activated interface control system was developed for lab-on-a-chip applications. The system consists of a straight rectangular microchannel, a fluorescence excitation source, a detection sensor, a signal conversion circuit, and a high-voltage feedback system. Aqueous NaCl as conducting fluid and aqueous glycerol as nonconducting fluid were introduced to flow side by side into the straight rectangular microchannel. Fluorescent dye was added to the aqueous NaCl to work as a signal representing the interface position. Automatic control of the liquid interface was achieved by controlling the electroosmotic effect that exists only in the conducting fluid using a high-voltage feedback system. A LABVIEW program was developed to control the output of high-voltage power supply according the actual interface position, and then the interface position is modified as the output of high-voltage power supply. At last, the interface can be moved to the desired position automatically using this feedback system. The results show that the system presented in this paper can control an arbitrary interface location in real time. The effects of viscosity ratio, flow rates, and polarity of electric field were discussed. This technique can be extended to switch the sample flow and droplets automatically. PMID:21173886

  16. The control of ultrasonic transmission by the metamaterials structure of electrorheological fluid and metal foam

    NASA Astrophysics Data System (ADS)

    Li, Linlin; Wang, Mingzhong; Wang, Jiahui; Zhao, Xiaopeng

    2017-11-01

    A metamaterial structure formed by foamed metal and starch and oil-based electrorheological (ER) fluid is designed in this paper. Experiments show that the metamaterial structure exhibits a regulation effect on the amplitude and phase of the transmitted waves of 35-80 kHz ultra-wideband ultrasonic waves in water. With the increase of the electric field, the transmission amplitude and phase of the ultrasonic wave increases, whereas the control ability of the same gradient electric field decreases. The amplitude of the transmission controlled by the metamaterial structure and electric field increases at first, and then decreases with the increase in volume fraction of the ER fluid. Thus, it is thought that the interaction between the microstructure produced by the rheological properties of the ER fluid and the porous foam metal affects the propagation of the acoustic wave.

  17. Power-based Shift Schedule for Pure Electric Vehicle with a Two-speed Automatic Transmission

    NASA Astrophysics Data System (ADS)

    Wang, Jiaqi; Liu, Yanfang; Liu, Qiang; Xu, Xiangyang

    2016-11-01

    This paper introduces a comprehensive shift schedule for a two-speed automatic transmission of pure electric vehicle. Considering about driving ability and efficiency performance of electric vehicles, the power-based shift schedule is proposed with three principles. This comprehensive shift schedule regards the vehicle current speed and motor load power as input parameters to satisfy the vehicle driving power demand with lowest energy consumption. A simulation model has been established to verify the dynamic and economic performance of comprehensive shift schedule. Compared with traditional dynamic and economic shift schedules, simulation results indicate that the power-based shift schedule is superior to traditional shift schedules.

  18. Optimal shifting control strategy in inertia phase of an automatic transmission for automotive applications

    NASA Astrophysics Data System (ADS)

    Meng, Fei; Tao, Gang; Zhang, Tao; Hu, Yihuai; Geng, Peng

    2015-08-01

    Shifting quality is a crucial factor in all parts of the automobile industry. To ensure an optimal gear shifting strategy with best fuel economy for a stepped automatic transmission, the controller should be designed to meet the challenge of lacking of a feedback sensor to measure the relevant variables. This paper focuses on a new kind of automatic transmission using proportional solenoid valve to control the clutch pressure, a speed difference of the clutch based control strategy is designed for the shift control during the inertia phase. First, the mechanical system is shown and the system dynamic model is built. Second, the control strategy is designed based on the characterization analysis of models which are derived from dynamics of the drive line and electro-hydraulic actuator. Then, the controller uses conventional Proportional-Integral-Derivative control theory, and a robust two-degree-of-freedom controller is also carried out to determine the optimal control parameters to further improve the system performance. Finally, the designed control strategy with different controller is implemented on a simulation model. The compared results show that the speed difference of clutch can track the desired trajectory well and improve the shift quality effectively.

  19. 78 FR 16247 - Foreign-Trade Zone 38-Spartanburg County, South Carolina; Authorization of Production Activity...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-14

    ... DEPARTMENT OF COMMERCE Foreign-Trade Zones Board [B-86-2012] Foreign-Trade Zone 38--Spartanburg County, South Carolina; Authorization of Production Activity; ZF Transmissions Gray Court, LLC (Automatic Transmissions); Gray Court, South Carolina On November 8, 2012, the South Carolina State Ports Authority...

  20. Conceptual design study of an Improved Gas Turbine (IGT) powertrain

    NASA Technical Reports Server (NTRS)

    Johnson, R. A.

    1979-01-01

    Design concepts for an improved automotive gas turbine powertrain are discussed. Twenty percent fuel economy improvement (over 1976), competitive costs (initial and life cycle), high reliability/life, low emissions, and noise/safety compliance were among the factors considered. The powertrain selected consists of a two shaft gas turbine engine with variable geometry aerodynamic components and a single disk rotating regenerator. The regenerator disk, gasifier turbine rotor, and several hot section flowpath parts are ceramic. The powertrain utilizes a conventional automatic transmission. The closest competitor was a single shaft turbine engine matched to a continuously variable transmission (CVT). Both candidate powertrain systems were found to be similar in many respects; however, the CVT represented a significant increase in development cost, technical risk, and production start-up costs over the conventional automatic transmission. Installation of the gas turbine powertrain was investigated for a transverse mounted, front wheel drive vehicle.

  1. Computer controllable synchronous shifting of an automatic transmission

    DOEpatents

    Davis, R.I.; Patil, P.B.

    1989-08-08

    A multiple forward speed automatic transmission produces its lowest forward speed ratio when a hydraulic clutch and hydraulic brake are disengaged and a one-way clutch connects a ring gear to the transmission casing. Second forward speed ratio results when the hydraulic clutch is engaged to connect the ring gear to the planetary carrier of a second gear set. Reverse drive and regenerative operation result when an hydraulic brake fixes the planetary and the direction of power flow is reversed. Various sensors produce signals representing the torque at the output of the transmission or drive wheels, the speed of the power source, and the hydraulic pressure applied to a clutch and brake. A control algorithm produces input data representing a commanded upshift, a commanded downshift, a commanded transmission output torque, and commanded power source speed. A microprocessor processes the inputs and produces a response to them in accordance with the execution of a control algorithm. Output or response signals cause selective engagement and disengagement of the clutch and brake at a rate that satisfies the requirements for a short gear ratio change and smooth torque transfer between the friction elements. 6 figs.

  2. Automatic sequential fluid handling with multilayer microfluidic sample isolated pumping

    PubMed Central

    Liu, Jixiao; Fu, Hai; Yang, Tianhang; Li, Songjing

    2015-01-01

    To sequentially handle fluids is of great significance in quantitative biology, analytical chemistry, and bioassays. However, the technological options are limited when building such microfluidic sequential processing systems, and one of the encountered challenges is the need for reliable, efficient, and mass-production available microfluidic pumping methods. Herein, we present a bubble-free and pumping-control unified liquid handling method that is compatible with large-scale manufacture, termed multilayer microfluidic sample isolated pumping (mμSIP). The core part of the mμSIP is the selective permeable membrane that isolates the fluidic layer from the pneumatic layer. The air diffusion from the fluidic channel network into the degassing pneumatic channel network leads to fluidic channel pressure variation, which further results in consistent bubble-free liquid pumping into the channels and the dead-end chambers. We characterize the mμSIP by comparing the fluidic actuation processes with different parameters and a flow rate range of 0.013 μl/s to 0.097 μl/s is observed in the experiments. As the proof of concept, we demonstrate an automatic sequential fluid handling system aiming at digital assays and immunoassays, which further proves the unified pumping-control and suggests that the mμSIP is suitable for functional microfluidic assays with minimal operations. We believe that the mμSIP technology and demonstrated automatic sequential fluid handling system would enrich the microfluidic toolbox and benefit further inventions. PMID:26487904

  3. Mode Propagation in Nonuniform Circular Ducts with Potential Flow

    NASA Technical Reports Server (NTRS)

    Cho, Y. C.; Ingard, K. U.

    1982-01-01

    A previously reported closed form solution is expanded to determine effects of isentropic mean flow on mode propagation in a slowly converging-diverging duct, a circular cosh duct. On the assumption of uniform steady fluid density, the mean flow increases the power transmission coefficient. The increase is directly related to the increase of the cutoff ratio at the duct throat. With the negligible transverse gradients of the steady fluid variables, the conversion from one mode to another is negligible, and the power transmission coefficient remains unchanged with the mean flow direction reversed. With a proper choice of frequency parameter, many different modes can be made subject to a single value of the power transmission loss. A systematic method to include the effects of the gradients of the steady fluid variables is also described.

  4. AUTOMOTIVE DIESEL MAINTENANCE 2. UNIT III, AUTOMATIC TRANSMISSIONS--HYDRAULICS (PART I).

    ERIC Educational Resources Information Center

    Human Engineering Inst., Cleveland, OH.

    THIS MODULE OF A 25-MODULE COURSE IS DESIGNED TO INTRODUCE BASIC HYDRAULIC PRINCIPLES AND PROVIDE AN UNDERSTANDING OF HYDRAULIC TRANSMISSIONS USED IN DIESEL POWERED VEHICLES. TOPICS ARE WHY USE HYDRAULICS, REVIEWING BASIC PHYSICS LAWS IN RELATION TO HYDRAULICS, UNDERSTANDING THE HYDRAULIC SYSTEM, AND DEVELOPING A BASIC HYDRAULIC SYSTEM. THE MODULE…

  5. AUTOMOTIVE DIESEL MAINTENANCE 2. UNIT IX, AUTOMATIC TRANSMISSIONS--HYDRAULIC SYSTEM (PART I).

    ERIC Educational Resources Information Center

    Human Engineering Inst., Cleveland, OH.

    THIS MODULE OF A 25-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OIL FLOW WITHIN HYDRAULIC TRANSMISSIONS USED ON DIESEL POWERED VEHICLES. TOPICS ARE GENERAL DESCRIPTION, HYDRAULIC CIRCUITS, AND BRAKE HYDRAULIC CIRCUIT AND OPERATION. THE MODULE CONSISTS OF A SELF-INSTRUCTIONAL PROGRAMED TRAINING FILM "LEARNING ABOUT THE ALLISON…

  6. 47 CFR 73.1570 - Modulation levels: AM, FM, TV and Class A TV aural.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... objectionable loudness or to maintain the dynamic range of the program material, the degree of modulation may be... stereophonic transmission signal modulation specifications of stereophonic system in use. (ii) For AM stations transmitting telemetry signals for remote control or automatic transmission system operation, the amplitude of...

  7. Automatic Transmission/Transaxle Specialist. Instructor Manual and Student Workbook. Automotive Service Series.

    ERIC Educational Resources Information Center

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This curriculum guide for transmission/transaxle specialist is one in a series of automotive service speciality publications that is based on the National Institute of Automotive Service Excellence task lists. The curriculum contains nine units. Each unit of instruction includes some or all of the following components: objective sheet,…

  8. Transmission loss of orthogonally rib-stiffened double-panel structures with cavity absorption.

    PubMed

    Xin, F X; Lu, T J

    2011-04-01

    The transmission loss of sound through infinite orthogonally rib-stiffened double-panel structures having cavity-filling fibrous sound absorptive materials is theoretically investigated. The propagation of sound across the fibrous material is characterized using an equivalent fluid model, and the motions of the rib-stiffeners are described by including all possible vibrations, i.e., flexural displacements, bending, and torsional rotations. The effects of fluid-structure coupling are account for by enforcing velocity continuity conditions at fluid-panel interfaces. By taking full advantage of the periodic nature of the double-panel, the space-harmonic approach and virtual work principle are applied to solve the sets of resultant governing equations, which are eventually truncated as a finite system of simultaneous algebraic equations and numerically solved insofar as the solution converges. To validate the proposed model, a comparison between the present model predictions and existing numerical and experimental results for a simplified version of the double-panel structure is carried out, with overall agreement achieved. The model is subsequently employed to explore the influence of the fluid-structure coupling between fluid in the cavity and the two panels on sound transmission across the orthogonally rib-stiffened double-panel structure. Obtained results demonstrate that this fluid-structure coupling affects significantly sound transmission loss (STL) at low frequencies and cannot be ignored when the rib-stiffeners are sparsely distributed. As a highlight of this research, an integrated optimal algorithm toward lightweight, high-stiffness and superior sound insulation capability is proposed, based on which a preliminary optimal design of the double-panel structure is performed.

  9. Automatic-repeat-request error control schemes

    NASA Technical Reports Server (NTRS)

    Lin, S.; Costello, D. J., Jr.; Miller, M. J.

    1983-01-01

    Error detection incorporated with automatic-repeat-request (ARQ) is widely used for error control in data communication systems. This method of error control is simple and provides high system reliability. If a properly chosen code is used for error detection, virtually error-free data transmission can be attained. Various types of ARQ and hybrid ARQ schemes, and error detection using linear block codes are surveyed.

  10. Resource Manual for Handling Body Fluids in the School Setting To Prevent Transmission of Human Immunodeficiency Virus and Hepatitis B Virus. Revised Edition.

    ERIC Educational Resources Information Center

    Maryland State Dept. of Health and Mental Hygiene, Baltimore.

    This Maryland resource manual provides local education agencies with guidelines on how to handle body fluids to prevent the transmission of diseases, especially Human Immunodeficiency Virus (HIV) and Hepatitis B Virus (HBV), in the school setting. The first section summarizes the reasons for development of the manual. The second section summarizes…

  11. White matter lesion extension to automatic brain tissue segmentation on MRI.

    PubMed

    de Boer, Renske; Vrooman, Henri A; van der Lijn, Fedde; Vernooij, Meike W; Ikram, M Arfan; van der Lugt, Aad; Breteler, Monique M B; Niessen, Wiro J

    2009-05-01

    A fully automated brain tissue segmentation method is optimized and extended with white matter lesion segmentation. Cerebrospinal fluid (CSF), gray matter (GM) and white matter (WM) are segmented by an atlas-based k-nearest neighbor classifier on multi-modal magnetic resonance imaging data. This classifier is trained by registering brain atlases to the subject. The resulting GM segmentation is used to automatically find a white matter lesion (WML) threshold in a fluid-attenuated inversion recovery scan. False positive lesions are removed by ensuring that the lesions are within the white matter. The method was visually validated on a set of 209 subjects. No segmentation errors were found in 98% of the brain tissue segmentations and 97% of the WML segmentations. A quantitative evaluation using manual segmentations was performed on a subset of 6 subjects for CSF, GM and WM segmentation and an additional 14 for the WML segmentations. The results indicated that the automatic segmentation accuracy is close to the interobserver variability of manual segmentations.

  12. Evaluation of the use of automatic exposure control and automatic tube potential selection in low-dose cerebrospinal fluid shunt head CT.

    PubMed

    Wallace, Adam N; Vyhmeister, Ross; Bagade, Swapnil; Chatterjee, Arindam; Hicks, Brandon; Ramirez-Giraldo, Juan Carlos; McKinstry, Robert C

    2015-06-01

    Cerebrospinal fluid shunts are primarily used for the treatment of hydrocephalus. Shunt complications may necessitate multiple non-contrast head CT scans resulting in potentially high levels of radiation dose starting at an early age. A new head CT protocol using automatic exposure control and automated tube potential selection has been implemented at our institution to reduce radiation exposure. The purpose of this study was to evaluate the reduction in radiation dose achieved by this protocol compared with a protocol with fixed parameters. A retrospective sample of 60 non-contrast head CT scans assessing for cerebrospinal fluid shunt malfunction was identified, 30 of which were performed with each protocol. The radiation doses of the two protocols were compared using the volume CT dose index and dose length product. The diagnostic acceptability and quality of each scan were evaluated by three independent readers. The new protocol lowered the average volume CT dose index from 15.2 to 9.2 mGy representing a 39 % reduction (P < 0.01; 95 % CI 35-44 %) and lowered the dose length product from 259.5 to 151.2 mGy/cm representing a 42 % reduction (P < 0.01; 95 % CI 34-50 %). The new protocol produced diagnostically acceptable scans with comparable image quality to the fixed parameter protocol. A pediatric shunt non-contrast head CT protocol using automatic exposure control and automated tube potential selection reduced patient radiation dose compared with a fixed parameter protocol while producing diagnostic images of comparable quality.

  13. Osmosis-driven viscous fingering of oil-in-water emulsions

    NASA Astrophysics Data System (ADS)

    Liu, Ying; Rallabandi, Bhargav; Baskaran, Mrudhula; Stone, Howard

    2017-11-01

    Viscous fingering occurs when a low viscosity fluid invades a more viscous fluid. Fingering of two miscible fluids is more complicated than that of immiscible fluids in that there is no sharp fluid-fluid interface and diffusion occurs between the phases. We experimentally studied the fingering of two miscible fluids: an oil-in-water emulsion and a sodium chloride solution. When the concentration of sodium chloride in the water phase in the emulsion exceeds that in the sodium chloride solution, the consequent osmotic flow automatically facilitates the occurrence of the fingering. On the contrary, when the sodium chloride solution has higher concentration, the spreading of emulsion is more uniform than the case without the concentration difference. We provide a model to rationalize and quantify these observations.

  14. Reflection and transmission coefficients of a single layer in poroelastic media.

    PubMed

    Corredor, Robiel Martinez; Santos, Juan E; Gauzellino, Patricia M; Carcione, José M

    2014-06-01

    Wave propagation in poroelastic media is a subject that finds applications in many fields of research, from geophysics of the solid Earth to material science. In geophysics, seismic methods are based on the reflection and transmission of waves at interfaces or layers. It is a relevant canonical problem, which has not been solved in explicit form, i.e., the wave response of a single layer, involving three dissimilar media, where the properties of the media are described by Biot's theory. The displacement fields are recast in terms of potentials and the boundary conditions at the two interfaces impose continuity of the solid and fluid displacements, normal and shear stresses, and fluid pressure. The existence of critical angles is discussed. The results are verified by taking proper limits-zero and 100% porosity-by comparison to the canonical solutions corresponding to single-phase solid (elastic) media and fluid media, respectively, and the case where the layer thickness is zero, representing an interface separating two poroelastic half-spaces. As examples, it was calculated the reflection and transmission coefficients for plane wave incident at a highly permeable and compliant fluid-saturated porous layer, and the case where the media are saturated with the same fluid.

  15. Simplified method to solve sound transmission through structures lined with elastic porous material.

    PubMed

    Lee, J H; Kim, J

    2001-11-01

    An approximate analysis method is developed to calculate sound transmission through structures lined with porous material. Because the porous material has both the solid phase and fluid phase, three wave components exist in the material, which makes the related analysis very complicated. The main idea in developing the approximate method is very simple: modeling the porous material using only the strongest of the three waves, which in effect idealizes the material as an equivalent fluid. The analysis procedure has to be conducted in two steps. In the first step, sound transmission through a flat double panel with a porous liner of infinite extents, which has the same cross sectional construction as the actual structure, is solved based on the full theory and the strongest wave component is identified. In the second step sound transmission through the actual structure is solved modeling the porous material as an equivalent fluid while using the actual geometry of the structure. The development and validation of the method are discussed in detail. As an application example, the transmission loss through double walled cylindrical shells with a porous core is calculated utilizing the simplified method.

  16. GUIDES TO POLLUTION PREVENTION: THE AUTO REPAIR INDUSTRY

    EPA Science Inventory

    Automotive maintenance and repair shops generate a variety of waste streams during activities such as replacing fluids (e.g., motor oil, radiator coolant, transmission fluid, brake fluid), replacing non-repairable parts (e.g., brake shoes/pads, shocks, batteries, belts, mufflers,...

  17. AUTOMOTIVE DIESEL MAINTENANCE 2 UNIT IV, AUTOMATIC TRANSMISSIONS--HYDRAULICS (PART II).

    ERIC Educational Resources Information Center

    Human Engineering Inst., Cleveland, OH.

    THIS MODULE OF A 25-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OPERATION AND MAINTENANCE OF VALVES UTILIZED IN HYDRAULIC TRANSMISSIONS USED ON DIESEL POWERED VEHICLES. TOPICS ARE (1) REVIEWING FACTS ABOUT PUMPS, (2) USING VALVES FOR CONTROL, (3) TROUBLESHOOTING PROCEDURES ON RELIEF VALVES, (4) USING DIRECTIONAL CONTROL VALVES,…

  18. Design and first results of CytoBuoy: a wireless flow cytometer for in situ analysis of marine and fresh waters.

    PubMed

    Dubelaar, G B; Gerritzen, P L; Beeker, A E; Jonker, R R; Tangen, K

    1999-12-01

    The high costs of microscopical determination and counting of phytoplankton often limit sampling frequencies below an acceptable level for the monitoring of dynamic ecosystems. Although having a limited discrimination power, flow cytometry allows the analysis of large numbers of samples to a level that is sufficient for many basic monitoring jobs. For this purpose, flow cytometers should not be restricted to research laboratories. We report here on the development of an in situ flow cytometer for autonomous operation inside a small moored buoy or on other platforms. Operational specifications served a wide range of applications in the aquatic field. Specific conditions had to be met with respect to the operation platform and autonomy. A small, battery-operated flow cytometer resulted, requiring no external sheath fluid supply. Because it was designed to operate in a buoy, we call it CytoBuoy. Sampling, analysis, and radio transmission of the data proceed automatically at user-defined intervals. A powerful feature is the acquisition and radio transmission of full detector pulse shapes of each particle. This provides valuable morphological information for particles larger than the 5-microm laser focus. CytoBuoy allows on-line in situ particle analysis, estimation of phytoplankton biomass, and discrimination between different phytoplankton groups. This will increase the applicability of flow cytometry in the field of environmental monitoring. Copyright 1999 Wiley-Liss, Inc.

  19. Inverse modeling of hydraulic tests in fractured crystalline rock based on a transition probability geostatistical approach

    NASA Astrophysics Data System (ADS)

    Blessent, Daniela; Therrien, René; Lemieux, Jean-Michel

    2011-12-01

    This paper presents numerical simulations of a series of hydraulic interference tests conducted in crystalline bedrock at Olkiluoto (Finland), a potential site for the disposal of the Finnish high-level nuclear waste. The tests are in a block of crystalline bedrock of about 0.03 km3 that contains low-transmissivity fractures. Fracture density, orientation, and fracture transmissivity are estimated from Posiva Flow Log (PFL) measurements in boreholes drilled in the rock block. On the basis of those data, a geostatistical approach relying on a transitional probability and Markov chain models is used to define a conceptual model based on stochastic fractured rock facies. Four facies are defined, from sparsely fractured bedrock to highly fractured bedrock. Using this conceptual model, three-dimensional groundwater flow is then simulated to reproduce interference pumping tests in either open or packed-off boreholes. Hydraulic conductivities of the fracture facies are estimated through automatic calibration using either hydraulic heads or both hydraulic heads and PFL flow rates as targets for calibration. The latter option produces a narrower confidence interval for the calibrated hydraulic conductivities, therefore reducing the associated uncertainty and demonstrating the usefulness of the measured PFL flow rates. Furthermore, the stochastic facies conceptual model is a suitable alternative to discrete fracture network models to simulate fluid flow in fractured geological media.

  20. Power and energy ratios in mechanical CVT drive control

    NASA Astrophysics Data System (ADS)

    Balakin, P. D.; Stripling, L. O.

    2017-06-01

    Being based on the principle of providing the systems with adaptation property to the real parameters and operational condition, the mechanical system capable to control automatically the components of convertible power is offered and this allows providing stationary operation of the vehicle engine in the terms of variable external loading. This is achieved by drive control integrated in the power transmission, which implements an additional degree of freedom and operates on the basis of the laws of motion, with the energy of the main power flow by changing automatically the kinematic characteristics of the power transmission, this system being named CVT. The power and energy ratios found allow performing the necessary design calculations of the sections and the links of the mechanical CVT scheme.

  1. Software Implements a Space-Mission File-Transfer Protocol

    NASA Technical Reports Server (NTRS)

    Rundstrom, Kathleen; Ho, Son Q.; Levesque, Michael; Sanders, Felicia; Burleigh, Scott; Veregge, John

    2004-01-01

    CFDP is a computer program that implements the CCSDS (Consultative Committee for Space Data Systems) File Delivery Protocol, which is an international standard for automatic, reliable transfers of files of data between locations on Earth and in outer space. CFDP administers concurrent file transfers in both directions, delivery of data out of transmission order, reliable and unreliable transmission modes, and automatic retransmission of lost or corrupted data by use of one or more of several lost-segment-detection modes. The program also implements several data-integrity measures, including file checksums and optional cyclic redundancy checks for each protocol data unit. The metadata accompanying each file can include messages to users application programs and commands for operating on remote file systems.

  2. An Application of Cartesian-Grid and Volume-of-Fluid Methods to Numerical Ship Hydrodynamics

    DTIC Science & Technology

    2007-10-01

    water-particle ve- locity is discontinuous across the air-water interface, and where CiEA is the Levi - Civita function. rj is the moment the vertical...methods and volume-of- immersed- body and volume-of-fluid (VOF) methods. fluid methods is used to simulate breaking waves around The governing equations are...of a ship hull is used as input to automat- body -fitted grids. The sole geometric input into NFA ically generate an immersed-boundary representation of

  3. Trapped-mode-induced Fano resonance and acoustical transparency in a one-dimensional solid-fluid phononic crystal

    NASA Astrophysics Data System (ADS)

    Quotane, Ilyasse; El Boudouti, El Houssaine; Djafari-Rouhani, Bahram

    2018-01-01

    We investigate theoretically and numerically the possibility of existence of Fano and acoustic-induced transparency (AIT) resonances in a simple though realistic one-dimensional acoustic structure made of solid-fluid layers inserted between two fluids. These resonances are obtained by combining appropriately the zeros of transmission (antiresonance) induced by the solid layers and the local resonances induced by the solid or combined solid-fluid layers with surface free boundary conditions. In particular, we show the possibility of trapped modes, also called bound states in continuum, which have recently found a high renewal interest. These modes appear as resonances with zero width in the transmission spectra as well as in the density of states (DOS). We consider three different structures: (i) a single solid layer inserted between two fluids. This simple structure shows the possibility of existence of trapped modes, which are discrete modes of the solid layer that lie in the continuum modes of the surrounding fluids. We give explicit analytical expressions of the dispersion relation of these eigenmodes of the solid layer which are found independent of the nature of the surrounding fluids. By slightly detuning the angle of incidence from that associated to the trapped mode, we get a well-defined Fano resonance characterized by an asymmetric Fano profile in the transmission spectra. (ii) The second structure consists of a solid-fluid-solid triple layer embedded between two fluids. This structure is found more appropriate to show both Fano and acoustic-induced transparency resonances. We provide detailed analytical expressions for the transmission and reflection coefficients that enable us to deduce a closed-form expression of the dispersion relation giving the trapped modes. Two situations can be distinguished in the triple-layer system: in the case of a symmetric structure (i.e., the same solid layers) we show, by detuning the incidence angle θ , the possibility of existence of Fano resonances that can be fitted following a Fano-type expression. The variation of the Fano parameter that describes the asymmetry of such resonances as well as their width versus θ is studied in detail. In the case of an asymmetric structure (i.e., different solid layers), we show the existence of an incidence angle that enables to squeeze a resonance between two transmission zeros induced by the two solid layers. This resonance behaves like an AIT resonance, its position and width depend on the nature of the fluid and solid layers as well as on the difference between the thicknesses of the solid layers. (iii) In the case of a periodic structure (phononic crystal), we show that trapped modes and Fano resonances give rise, respectively, to dispersionless flat bands with zero group velocity and nearly flat bands with negative or positive group velocities. The analytical results presented here are obtained by means of the Green's function method which enables to deduce in closed form: dispersion curves, transmission and reflection coefficients, DOS, as well as the displacement fields. The proposed solid-fluid layered structures should have important applications for designing acoustic mirrors and acoustic filters as well as supersonic and subsonic materials.

  4. Fuel economy screening study of advanced automotive gas turbine engines

    NASA Technical Reports Server (NTRS)

    Klann, J. L.

    1980-01-01

    Fuel economy potentials were calculated and compared among ten turbomachinery configurations. All gas turbine engines were evaluated with a continuously variable transmission in a 1978 compact car. A reference fuel economy was calculated for the car with its conventional spark ignition piston engine and three speed automatic transmission. Two promising engine/transmission combinations, using gasoline, had 55 to 60 percent gains over the reference fuel economy. Fuel economy sensitivities to engine design parameter changes were also calculated for these two combinations.

  5. Sound Transmission through Two Concentric Cylindrical Sandwich Shells

    NASA Technical Reports Server (NTRS)

    Tang, Yvette Y.; Silcox, Richard J.; Robinson, Jay H.

    1996-01-01

    This paper solves the problem of sound transmission through a system of two infinite concentric cylindrical sandwich shells. The shells are surrounded by external and internal fluid media and there is fluid (air) in the annular space between them. An oblique plane sound wave is incident upon the surface of the outer shell. A uniform flow is moving with a constant velocity in the external fluid medium. Classical thin shell theory is applied to the inner shell and first-order shear deformation theory is applied to the outer shell. A closed form for transmission loss is derived based on modal analysis. Investigations have been made for the impedance of both shells and the transmission loss through the shells from the exterior into the interior. Results are compared for double sandwich shells and single sandwich shells. This study shows that: (1) the impedance of the inner shell is much smaller than that of the outer shell so that the transmission loss is almost the same in both the annular space and the interior cavity of the shells; (2) the two concentric sandwich shells can produce an appreciable increase of transmission loss over single sandwich shells especially in the high frequency range; and (3) design guidelines may be derived with respect to the noise reduction requirement and the pressure in the annular space at a mid-frequency range.

  6. CONTROL ROD DRIVE MECHANISM FOR A NUCLEAR REACTOR

    DOEpatents

    Hawke, B.C.; Liederbach, F.J.; Lones, W.

    1963-05-14

    A lead-screw-type control rod drive featuring an electric motor and a fluid motor arranged to provide a selectably alternative driving means is described. The electric motor serves to drive the control rod slowly during normal operation, while the fluid motor, assisted by an automatic declutching of the electric motor, affords high-speed rod insertion during a scram. (AEC)

  7. Shock-operated valve would automatically protect fluid systems

    NASA Technical Reports Server (NTRS)

    Branum, L. W.; Wells, G. H.

    1966-01-01

    Glandless valve shuts down high-pressure fluid systems when severe shock from an explosion or earthquake occurs. The valve uses a pendulum to support the valve closure plug in the open position. When jarred, the valve body is moved relative to the pendulum and the plug support is displaced, allowing the plug to seat and be held by spring pressure.

  8. 75 FR 20787 - Airworthiness Directives; Bombardier, Inc. Model DHC-8-400, -401, and -402 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-21

    ... increased fluid flow within the No. 1 hydraulic system. In one case, the hydraulic system control logic did... (PTU) control logic, including the provision of automatic PTU shutdown in the event of loss of fluid in... one case, the hydraulic system control logic did not shut down the PTU and the overspeed condition...

  9. Elastic and viscoelastic effects in rubber/air acoustic band gap structures: A theoretical and experimental study

    NASA Astrophysics Data System (ADS)

    Merheb, B.; Deymier, P. A.; Jain, M.; Aloshyna-Lesuffleur, M.; Mohanty, S.; Berker, A.; Greger, R. W.

    2008-09-01

    The transmission of acoustic waves through centimeter-scale elastic and viscoelastic two-dimensional silicone rubber/air phononic crystal structures is investigated theoretically and experimentally. We introduce a finite difference time domain method for two-dimensional elastic and viscoelastic composite structures. Elastic fluid-solid phononic crystals composed of a two-dimensional array of cylindrical air inclusions in a solid rubber matrix, as well as an array of rubber cylinders in an air matrix, are shown to behave similarly to fluid-fluid composite structures. These systems exhibit very wide band gaps in their transmission spectra that extend to frequencies in the audible range of the spectrum. This effect is associated with the very low value of the transverse speed of sound in rubber compared to that of the longitudinal polarization. The difference in transmission between elastic and viscoelastic rubber/air crystals results from attenuation of transmission over a very wide frequency range, leaving only narrow passing bands at very low frequencies. These phononic crystals demonstrate the practical design of elastic or viscoelastic solid rubber/air acoustic band gap sound barriers with small dimensions.

  10. Method for controlling powertrain pumps

    DOEpatents

    Sime, Karl Andrew; Spohn, Brian L; Demirovic, Besim; Martini, Ryan D; Miller, Jean Marie

    2013-10-22

    A method of controlling a pump supplying a fluid to a transmission includes sensing a requested power and an excess power for a powertrain. The requested power substantially meets the needs of the powertrain, while the excess power is not part of the requested power. The method includes sensing a triggering condition in response to the ability to convert the excess power into heat in the transmission, and determining that an operating temperature of the transmission is below a maximum. The method also includes determining a calibrated baseline and a dissipation command for the pump. The calibrated baseline command is configured to supply the fluid based upon the requested power, and the dissipation command is configured to supply additional fluid and consume the excess power with the pump. The method operates the pump at a combined command, which is equal to the calibrated baseline command plus the dissipation command.

  11. Precise determination of the refractive index of suspended particles: light transmission as a function of refractive index mismatch

    NASA Astrophysics Data System (ADS)

    McClymer, J. P.

    2016-08-01

    Many fluids appear white because refractive index differences lead to multiple scattering. In this paper, we use safe, low-cost commercial index matching fluids to quantitatively study light transmission as a function of index mismatch, reduce multiple scattering to allow single scattering probes, and to precisely determine the index of refraction of suspended material. The transmission profile is compared with Rayleigh-Gans and Mie theory predictions. The procedure is accessible as a student laboratory project, while providing advantages over other standard methods of measuring the refractive index of an unknown nanoparticle, making it valuable to researchers.

  12. Increasing the reliability of the shutdown of 500 - 750-kV overhead lines equipped with shunt reactors in an unsuccessful three-phase automatic repeated closure cycle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuz'micheva, K. I.; Merzlyakov, A. S.; Fokin, G. G.

    2013-05-15

    The reasons for circuit-breaker failures during repeated disconnection of 500 - 750 kV overhead lines with shunt reactors in a cycle of unsuccessful three-phase automatic reconnection (TARC) are analyzed. Recommendations are made for increasing the operating reliability of power transmission lines with shunt reactors when there is unsuccessful reconnection.

  13. Study on Remote Monitoring System of Crossing and Spanning Tangent Tower

    NASA Astrophysics Data System (ADS)

    Chen, Da-bing; Zhang, Nai-long; Zhang, Meng-ge; Wang, Ze-hua; Zhang, Yan

    2017-05-01

    In order to grasp the vibration state of overhead transmission line and ensure the operational security of transmission line, the remote monitoring system of crossing and spanning tangent tower was studied. By use of this system, the displacement, velocity and acceleration of the tower, and the local weather data are collected automatically, displayed on computer of remote monitoring centre through wireless network, real-time collection and transmission of vibration signals are realized. The applying results show that the system is excellent in reliability and accuracy and so on. The system can be used to remote monitoring of transmission tower of UHV power transmission lines and in large spanning areas.

  14. Automatic gain control in the echolocation system of dolphins

    NASA Astrophysics Data System (ADS)

    Au, Whitlow W. L.; Benoit-Bird, Kelly J.

    2003-06-01

    In bats and technological sonars, the gain of the receiver is progressively increased with time after the transmission of a signal to compensate for acoustic propagation loss. The current understanding of dolphin echolocation indicates that automatic gain control is not a part of their sonar system. In order to test this understanding, we have performed field measurements of free-ranging echolocating dolphins. Here we show that dolphins do possess an automatic gain control mechanism, but that it is implemented in the transmission phase rather than the receiving phase of a sonar cycle. We find that the amplitude of the dolphins' echolocation signals are highly range dependent; this amplitude increases with increasing target range, R, in a 20log(R) fashion to compensate for propagation loss. If the echolocation target is a fish school with many sound scatterers, the echoes from the school will remain nearly constant with range as the dolphin closes in on it. This characteristic has the same effect as time-varying gain in bats and technological sonar when considered from a sonar system perspective.

  15. The automatic back-check mechanism of mask tooling database and automatic transmission of mask tooling data

    NASA Astrophysics Data System (ADS)

    Xu, Zhe; Peng, M. G.; Tu, Lin Hsin; Lee, Cedric; Lin, J. K.; Jan, Jian Feng; Yin, Alb; Wang, Pei

    2006-10-01

    Nowadays, most foundries have paid more and more attention in order to reduce the CD width. Although the lithography technologies have developed drastically, mask data accuracy is still a big challenge than before. Besides, mask (reticle) price also goes up drastically such that data accuracy needs more special treatments.We've developed a system called eFDMS to guarantee the mask data accuracy. EFDMS is developed to do the automatic back-check of mask tooling database and the data transmission of mask tooling. We integrate our own EFDMS systems to engage with the standard mask tooling system K2 so that the upriver and the downriver processes of the mask tooling main body K2 can perform smoothly and correctly with anticipation. The competition in IC marketplace is changing from high-tech process to lower-price gradually. How to control the reduction of the products' cost more plays a significant role in foundries. Before the violent competition's drawing nearer, we should prepare the cost task ahead of time.

  16. A simple bubble-flowmeter with quasicontinuous registration.

    PubMed

    Ludt, H; Herrmann, H D

    1976-07-22

    The construction of a simple bubble-flow-meter is described. The instrument has the following features: 1. automatic bubble injection, 2. precise measurement of the bubble passage time by a digital counter, 3. quasicontinuous registration of the flow rate, 4. alternative run with clear fluid (water) and coloured fluid (blood), 5. low volume, 6. closed measuring system for measurements in low and high pressure systems.

  17. 40 CFR 1065.510 - Engine mapping.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... Configure any auxiliary work inputs and outputs such as hybrid, turbo-compounding, or thermoelectric systems... intended primarily for propulsion of a vehicle with an automatic transmission where that engine is subject...

  18. Cooling system with automated seasonal freeze protection

    DOEpatents

    Campbell, Levi A.; Chu, Richard C.; David, Milnes P.; Ellsworth, Jr., Michael J.; Iyengar, Madhusudan K.; Simons, Robert E.; Singh, Prabjit; Zhang, Jing

    2016-05-24

    An automated multi-fluid cooling system and method are provided for cooling an electronic component(s). The cooling system includes a coolant loop, a coolant tank, multiple valves, and a controller. The coolant loop is at least partially exposed to outdoor ambient air temperature(s) during normal operation, and the coolant tank includes first and second reservoirs containing first and second fluids, respectively. The first fluid freezes at a lower temperature than the second, the second fluid has superior cooling properties compared with the first, and the two fluids are soluble. The multiple valves are controllable to selectively couple the first or second fluid into the coolant in the coolant loop, wherein the coolant includes at least the second fluid. The controller automatically controls the valves to vary first fluid concentration level in the coolant loop based on historical, current, or anticipated outdoor air ambient temperature(s) for a time of year.

  19. Cooling method with automated seasonal freeze protection

    DOEpatents

    Cambell, Levi; Chu, Richard; David, Milnes; Ellsworth, Jr, Michael; Iyengar, Madhusudan; Simons, Robert; Singh, Prabjit; Zhang, Jing

    2016-05-31

    An automated multi-fluid cooling method is provided for cooling an electronic component(s). The method includes obtaining a coolant loop, and providing a coolant tank, multiple valves, and a controller. The coolant loop is at least partially exposed to outdoor ambient air temperature(s) during normal operation, and the coolant tank includes first and second reservoirs containing first and second fluids, respectively. The first fluid freezes at a lower temperature than the second, the second fluid has superior cooling properties compared with the first, and the two fluids are soluble. The multiple valves are controllable to selectively couple the first or second fluid into the coolant in the coolant loop, wherein the coolant includes at least the second fluid. The controller automatically controls the valves to vary first fluid concentration level in the coolant loop based on historical, current, or anticipated outdoor air ambient temperature(s) for a time of year.

  20. Development of risk reduction behavioral counseling for Ebola virus disease survivors enrolled in the Sierra Leone Ebola Virus Persistence Study, 2015-2016.

    PubMed

    Abad, Neetu; Malik, Tasneem; Ariyarajah, Archchun; Ongpin, Patricia; Hogben, Matthew; McDonald, Suzanna L R; Marrinan, Jaclyn; Massaquoi, Thomas; Thorson, Anna; Ervin, Elizabeth; Bernstein, Kyle; Ross, Christine; Liu, William J; Kroeger, Karen; Durski, Kara N; Broutet, Nathalie; Knust, Barbara; Deen, Gibrilla F

    2017-09-01

    During the 2014-2016 West Africa Ebola Virus Disease (EVD) epidemic, the public health community had concerns that sexual transmission of the Ebola virus (EBOV) from EVD survivors was a risk, due to EBOV persistence in body fluids of EVD survivors, particularly semen. The Sierra Leone Ebola Virus Persistence Study was initiated to investigate this risk by assessing EBOV persistence in numerous body fluids of EVD survivors and providing risk reduction counseling based on test results for semen, vaginal fluid, menstrual blood, urine, rectal fluid, sweat, tears, saliva, and breast milk. This publication describes implementation of the counseling protocol and the key lessons learned. The Ebola Virus Persistence Risk Reduction Behavioral Counseling Protocol was developed from a framework used to prevent transmission of HIV and other sexually transmitted infections. The framework helped to identify barriers to risk reduction and facilitated the development of a personalized risk-reduction plan, particularly around condom use and abstinence. Pre-test and post-test counseling sessions included risk reduction guidance, and post-test counseling was based on the participants' individual test results. The behavioral counseling protocol enabled study staff to translate the study's body fluid test results into individualized information for study participants. The Ebola Virus Persistence Risk Reduction Behavioral Counseling Protocol provided guidance to mitigate the risk of EBOV transmission from EVD survivors. It has since been shared with and adapted by other EVD survivor body fluid testing programs and studies in Ebola-affected countries.

  1. Transmission of heat from a flat plate to a fluid flowing at a high velocity

    NASA Technical Reports Server (NTRS)

    Crocco, Luigi

    1932-01-01

    The writer, starting with the consideration of the hydrodynamic and thermodynamic equations for the turbulent boundary layer of a flat plate when it is necessary to take into account the heat produced by friction, arrives at the conclusion that the transmission of the heat follows the same law that is valid when the frictional heat is negligible, provided the temperature of the fluid is considered to be that which the fluid would reach if arrested adiabatically. It is then shown how the same law holds good for faired bodies, and some applications of the law are made to the problems of flight at very high speeds.

  2. An analysis of environmental data transmission

    NASA Astrophysics Data System (ADS)

    Yuan, Lina; Chen, Huajun; Gong, Jing

    2017-05-01

    To comprehensively construct environmental automatic monitoring has become the urgent need of environmental management, is a major measure to implement the scientific outlook on development and build a harmonious socialist society, and is an inevitable choice of “building a resource-conserving and environment-friendly society”, which is of great importance and profound significance to adjust the economic structure and transform growth pattern. This article first introduces the importance of environmental data transmission, then expounds the characteristics, key technologies, transmitting mode, and design ideas of environmental data transmission process, and finally, summarizes the full text.

  3. Parallel Three-Dimensional Computation of Fluid Dynamics and Fluid-Structure Interactions of Ram-Air Parachutes

    NASA Technical Reports Server (NTRS)

    Tezduyar, Tayfun E.

    1998-01-01

    This is a final report as far as our work at University of Minnesota is concerned. The report describes our research progress and accomplishments in development of high performance computing methods and tools for 3D finite element computation of aerodynamic characteristics and fluid-structure interactions (FSI) arising in airdrop systems, namely ram-air parachutes and round parachutes. This class of simulations involves complex geometries, flexible structural components, deforming fluid domains, and unsteady flow patterns. The key components of our simulation toolkit are a stabilized finite element flow solver, a nonlinear structural dynamics solver, an automatic mesh moving scheme, and an interface between the fluid and structural solvers; all of these have been developed within a parallel message-passing paradigm.

  4. Human vaginal fluid contains exosomes that have an inhibitory effect on an early step of the HIV-1 life cycle.

    PubMed

    Smith, Johanna A; Daniel, Rene

    2016-11-13

    Vaginal transmission is crucial to the spread of HIV-1 around the world. It is not yet clear what type (s) of innate defenses against HIV-1 infection are present in the vagina. Here, we aimed to determine whether human vaginal fluid contains exosomes that may possess anti-HIV-1 activity. The exosomal fraction was isolated from samples of vaginal fluids. The presence of exosomes was confirmed by flow cytometry and western blotting. The newly discovered exosomes were tested for their ability to block early steps of HIV-1 infection in vitro using established cell culture systems and real time PCR-based methods. Vaginal fluid contains exosomes expressing CD9, CD63, and CD81 exosomal markers. The exosomal fraction of the fluid-reduced transmission of HIV-1 vectors by 60%, the efficiency of reverse transcription step by 58.4%, and the efficiency of integration by 47%. Exosomes had no effect on the entry of HIV-1 vectors. Human vaginal fluid exosomes are newly discovered female innate defenses that may protect women against HIV-1 infection.

  5. Thermal aging of melt-spun NdFeB magnetic powder in hydrogen

    NASA Astrophysics Data System (ADS)

    Pinkerton, Frederick E.; Balogh, Michael P.; Ellison, Nicole; Foto, Aldo; Sechan, Martin; Tessema, Misle M.; Thompson, Margarita P.

    2016-11-01

    High energy product neodymium-iron-boron (NdFeB) magnets are the premier candidate for demanding electrified vehicle traction motor applications. Injection molded (IM) or compression molded (CM) magnets made using NdFeB powders are promising routes to improve motor efficiency, cost, and manufacturability. However, IM and CM NdFeB magnets are susceptible to substantial thermal aging losses at motor operating temperatures when exposed to the automatic transmission fluid (ATF) used as a lubricant and cooling medium. The intrinsic coercivity Hci of NdFeB IM and CM magnets degrades by as much as 18% when aged for 1000 h in ATF at 150 °C, compared to a 3% loss when aged in air. Here we report aging studies of rapidly quenched NdFeB powder in air, ATF, and H2 gas. Expansion of the NdFeB crystal lattice in both ATF and H2 identified hydrogen dissociated from the ATF during aging and diffused into the primary NdFeB phase as the probable cause of the coercivity loss of IM and CM magnets.

  6. Anatomical and functional characteristics of carotid sinus stimulation in humans

    NASA Technical Reports Server (NTRS)

    Querry, R. G.; Smith, S. A.; Stromstad, M.; Ide, K.; Secher, N. H.; Raven, P. B.

    2001-01-01

    Transmission characteristics of pneumatic pressure to the carotid sinus were evaluated in 19 subjects at rest and during exercise. Either a percutaneous fluid-filled (n = 12) or balloon-tipped catheter (n = 7) was placed at the carotid bifurcation to record internal transmission of external neck pressure/neck suction (NP/NS). Sustained, 5-s pulses, and rapid ramping pulse protocols (+40 to -80 Torr) were recorded. Transmission of pressure stimuli was less with the fluid-filled catheter compared with that of the balloon-tipped catheter (65% vs. 82% negative pressure, 83% vs. 89% positive pressure; P < 0.05). Anatomical location of the carotid sinus averaged 3.2 cm (left) and 3.6 cm (right) from the gonion of the mandible with a range of 0-7.5 cm. Transmission was not altered by exercise or Valsalva maneuver, but did vary depending on the position of the carotid sinus locus beneath the sealed chamber. These data indicate that transmission of external NP/NS was higher than previously recorded in humans, and anatomical variation of carotid sinus location and equipment design can affect transmission results.

  7. iGeoT v1.0: Automatic Parameter Estimation for Multicomponent Geothermometry, User's Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spycher, Nicolas; Finsterle, Stefan

    GeoT implements the multicomponent geothermometry method developed by Reed and Spycher [1984] into a stand-alone computer program to ease the application of this method and to improve the prediction of geothermal reservoir temperatures using full and integrated chemical analyses of geothermal fluids. Reservoir temperatures are estimated from statistical analyses of mineral saturation indices computed as a function of temperature. The reconstruction of the deep geothermal fluid compositions, and geothermometry computations, are all implemented into the same computer program, allowing unknown or poorly constrained input parameters to be estimated by numerical optimization. This integrated geothermometry approach presents advantages over classical geothermometersmore » for fluids that have not fully equilibrated with reservoir minerals and/or that have been subject to processes such as dilution and gas loss. This manual contains installation instructions for iGeoT, and briefly describes the input formats needed to run iGeoT in Automatic or Expert Mode. An example is also provided to demonstrate the use of iGeoT.« less

  8. Predictive value of pulse pressure variation for fluid responsiveness in septic patients using lung-protective ventilation strategies.

    PubMed

    Freitas, F G R; Bafi, A T; Nascente, A P M; Assunção, M; Mazza, B; Azevedo, L C P; Machado, F R

    2013-03-01

    The applicability of pulse pressure variation (ΔPP) to predict fluid responsiveness using lung-protective ventilation strategies is uncertain in clinical practice. We designed this study to evaluate the accuracy of this parameter in predicting the fluid responsiveness of septic patients ventilated with low tidal volumes (TV) (6 ml kg(-1)). Forty patients after the resuscitation phase of severe sepsis and septic shock who were mechanically ventilated with 6 ml kg(-1) were included. The ΔPP was obtained automatically at baseline and after a standardized fluid challenge (7 ml kg(-1)). Patients whose cardiac output increased by more than 15% were considered fluid responders. The predictive values of ΔPP and static variables [right atrial pressure (RAP) and pulmonary artery occlusion pressure (PAOP)] were evaluated through a receiver operating characteristic (ROC) curve analysis. Thirty-four patients had characteristics consistent with acute lung injury or acute respiratory distress syndrome and were ventilated with high levels of PEEP [median (inter-quartile range) 10.0 (10.0-13.5)]. Nineteen patients were considered fluid responders. The RAP and PAOP significantly increased, and ΔPP significantly decreased after volume expansion. The ΔPP performance [ROC curve area: 0.91 (0.82-1.0)] was better than that of the RAP [ROC curve area: 0.73 (0.59-0.90)] and pulmonary artery occlusion pressure [ROC curve area: 0.58 (0.40-0.76)]. The ROC curve analysis revealed that the best cut-off for ΔPP was 6.5%, with a sensitivity of 0.89, specificity of 0.90, positive predictive value of 0.89, and negative predictive value of 0.90. Automatized ΔPP accurately predicted fluid responsiveness in septic patients ventilated with low TV.

  9. Automatic Generation of OpenMP Directives and Its Application to Computational Fluid Dynamics Codes

    NASA Technical Reports Server (NTRS)

    Yan, Jerry; Jin, Haoqiang; Frumkin, Michael; Yan, Jerry (Technical Monitor)

    2000-01-01

    The shared-memory programming model is a very effective way to achieve parallelism on shared memory parallel computers. As great progress was made in hardware and software technologies, performance of parallel programs with compiler directives has demonstrated large improvement. The introduction of OpenMP directives, the industrial standard for shared-memory programming, has minimized the issue of portability. In this study, we have extended CAPTools, a computer-aided parallelization toolkit, to automatically generate OpenMP-based parallel programs with nominal user assistance. We outline techniques used in the implementation of the tool and discuss the application of this tool on the NAS Parallel Benchmarks and several computational fluid dynamics codes. This work demonstrates the great potential of using the tool to quickly port parallel programs and also achieve good performance that exceeds some of the commercial tools.

  10. Low Resolution Picture Transmission (LRPT) Demonstration System. Phase II; 1.0

    NASA Technical Reports Server (NTRS)

    Fong, Wai; Yeh, Pen-Shu; Duran, Steve; Sank, Victor; Nyugen, Xuan; Xia, Wei; Day, John H. (Technical Monitor)

    2002-01-01

    Low-Resolution Picture Transmission (LRPT) is a proposed standard for direct broadcast transmission of satellite weather images. This standard is a joint effort by the European Organization for the Exploitation of Meteorological Satellites (EUMETSAT) and NOAA. As a digital transmission scheme, its purpose is to replace the current analog Automatic Picture Transmission (APT) system for use in the Meteorological Operational (METOP) satellites. GSFC has been tasked to build an LRPT Demonstration System (LDS). Its main objective is to develop or demonstrate the feasibility of a low-cost receiver utilizing a PC as the primary processing component and determine the performance of the protocol in the simulated Radio Frequency (RF) environment. The approach would consist of two phases.

  11. System for computer controlled shifting of an automatic transmission

    DOEpatents

    Patil, Prabhakar B.

    1989-01-01

    In an automotive vehicle having an automatic transmission that driveably connects a power source to the driving wheels, a method to control the application of hydraulic pressure to a clutch, whose engagement produces an upshift and whose disengagement produces a downshift, the speed of the power source, and the output torque of the transmission. The transmission output shaft torque and the power source speed are the controlled variables. The commanded power source torque and commanded hydraulic pressure supplied to the clutch are the control variables. A mathematical model is formulated that describes the kinematics and dynamics of the powertrain before, during and after a gear shift. The model represents the operating characteristics of each component and the structural arrangement of the components within the transmission being controlled. Next, a close loop feedback control is developed to determine the proper control law or compensation strategy to achieve an acceptably smooth gear ratio change, one in which the output torque disturbance is kept to a minimum and the duration of the shift is minimized. Then a computer algorithm simulating the shift dynamics employing the mathematical model is used to study the effects of changes in the values of the parameters established from a closed loop control of the clutch hydraulic and the power source torque on the shift quality. This computer simulation is used also to establish possible shift control strategies. The shift strategies determine from the prior step are reduced to an algorithm executed by a computer to control the operation of the power source and the transmission.

  12. Closed loop computer control for an automatic transmission

    DOEpatents

    Patil, Prabhakar B.

    1989-01-01

    In an automotive vehicle having an automatic transmission that driveably connects a power source to the driving wheels, a method to control the application of hydraulic pressure to a clutch, whose engagement produces an upshift and whose disengagement produces a downshift, the speed of the power source, and the output torque of the transmission. The transmission output shaft torque and the power source speed are the controlled variables. The commanded power source torque and commanded hydraulic pressure supplied to the clutch are the control variables. A mathematical model is formulated that describes the kinematics and dynamics of the powertrain before, during and after a gear shift. The model represents the operating characteristics of each component and the structural arrangement of the components within the transmission being controlled. Next, a close loop feedback control is developed to determine the proper control law or compensation strategy to achieve an acceptably smooth gear ratio change, one in which the output torque disturbance is kept to a minimum and the duration of the shift is minimized. Then a computer algorithm simulating the shift dynamics employing the mathematical model is used to study the effects of changes in the values of the parameters established from a closed loop control of the clutch hydraulic and the power source torque on the shift quality. This computer simulation is used also to establish possible shift control strategies. The shift strategies determined from the prior step are reduced to an algorithm executed by a computer to control the operation of the power source and the transmission.

  13. Automatic blood pressure measuring system (M091)

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The Leg Volume Measuring System is used to measure leg calf girth changes that occur during exposure to lower body negative pressure as a result of pooling of blood and other fluids in the lower extremities.

  14. Power system

    DOEpatents

    Hickam, Christopher Dale [Glasford, IL

    2008-03-18

    A power system includes a prime mover, a transmission, and a fluid coupler having a selectively engageable lockup clutch. The fluid coupler may be drivingly connected between the prime mover and the transmission. Additionally, the power system may include a motor/generator drivingly connected to at least one of the prime mover and the transmission. The power-system may also include power-system controls configured to execute a control method. The control method may include selecting one of a plurality of modes of operation of the power system. Additionally, the control method may include controlling the operating state of the lockup clutch dependent upon the mode of operation selected. The control method may also include controlling the operating state of the motor/generator dependent upon the mode of operation selected.

  15. Influence of thickness and permeability of endothelial surface layer on transmission of shear stress in capillaries

    NASA Astrophysics Data System (ADS)

    Zhang, SongPeng; Zhang, XiangJun; Tian, Yu; Meng, YongGang; Lipowsky, Herbert

    2015-07-01

    The molecular coating on the surface of microvascular endothelium has been identified as a barrier to transvascular exchange of solutes. With a thickness of hundreds of nanometers, this endothelial surface layer (ESL) has been treated as a porous domain within which fluid shear stresses are dissipated and transmitted to the solid matrix to initiate mechanotransduction events. The present study aims to examine the effects of the ESL thickness and permeability on the transmission of shear stress throughout the ESL. Our results indicate that fluid shear stresses rapidly decrease to insignificant levels within a thin transition layer near the outer boundary of the ESL with a thickness on the order of ten nanometers. The thickness of the transition zone between free fluid and the porous layer was found to be proportional to the square root of the Darcy permeability. As the permeability is reduced ten-fold, the interfacial fluid and solid matrix shear stress gradients increase exponentially two-fold. While the interfacial fluid shear stress is positively related to the ESL thickness, the transmitted matrix stress is reduced by about 50% as the ESL thickness is decreased from 500 to 100 nm, which may occur under pathological conditions. Thus, thickness and permeability of the ESL are two main factors that determine flow features and the apportionment of shear stresses between the fluid and solid phases of the ESL. These results may shed light on the mechanisms of force transmission through the ESL and the pathological events caused by alterations in thickness and permeability of the ESL.

  16. Development of risk reduction behavioral counseling for Ebola virus disease survivors enrolled in the Sierra Leone Ebola Virus Persistence Study, 2015-2016

    PubMed Central

    Malik, Tasneem; Ariyarajah, Archchun; Ongpin, Patricia; Hogben, Matthew; McDonald, Suzanna L. R.; Marrinan, Jaclyn; Massaquoi, Thomas; Thorson, Anna; Ervin, Elizabeth; Bernstein, Kyle; Ross, Christine; Liu, William J.; Kroeger, Karen; Durski, Kara N.; Broutet, Nathalie; Knust, Barbara; Deen, Gibrilla F.

    2017-01-01

    Background During the 2014–2016 West Africa Ebola Virus Disease (EVD) epidemic, the public health community had concerns that sexual transmission of the Ebola virus (EBOV) from EVD survivors was a risk, due to EBOV persistence in body fluids of EVD survivors, particularly semen. The Sierra Leone Ebola Virus Persistence Study was initiated to investigate this risk by assessing EBOV persistence in numerous body fluids of EVD survivors and providing risk reduction counseling based on test results for semen, vaginal fluid, menstrual blood, urine, rectal fluid, sweat, tears, saliva, and breast milk. This publication describes implementation of the counseling protocol and the key lessons learned. Methodology/Principal findings The Ebola Virus Persistence Risk Reduction Behavioral Counseling Protocol was developed from a framework used to prevent transmission of HIV and other sexually transmitted infections. The framework helped to identify barriers to risk reduction and facilitated the development of a personalized risk-reduction plan, particularly around condom use and abstinence. Pre-test and post-test counseling sessions included risk reduction guidance, and post-test counseling was based on the participants’ individual test results. The behavioral counseling protocol enabled study staff to translate the study’s body fluid test results into individualized information for study participants. Conclusions/Significance The Ebola Virus Persistence Risk Reduction Behavioral Counseling Protocol provided guidance to mitigate the risk of EBOV transmission from EVD survivors. It has since been shared with and adapted by other EVD survivor body fluid testing programs and studies in Ebola-affected countries. PMID:28892490

  17. Automatic instrument for chemical processing to detect microorganism in biological samples by measuring light reactions

    NASA Technical Reports Server (NTRS)

    Kelbaugh, B. N.; Picciolo, G. L.; Chappelle, E. W.; Colburn, M. E. (Inventor)

    1973-01-01

    An automated apparatus is reported for sequentially assaying urine samples for the presence of bacterial adenosine triphosphate (ATP) that comprises a rotary table which carries a plurality of sample containing vials and automatically dispenses fluid reagents into the vials preparatory to injecting a light producing luciferase-luciferin mixture into the samples. The device automatically measures the light produced in each urine sample by a bioluminescence reaction of the free bacterial adenosine triphosphate with the luciferase-luciferin mixture. The light measured is proportional to the concentration of bacterial adenosine triphosphate which, in turn, is proportional to the number of bacteria present in the respective urine sample.

  18. 47 CFR 87.479 - Harmful interference to radionavigation land stations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... to establish wide-band systems using frequency-hopping spread spectrum techniques in the 960-1215 MHz.... Transmissions will be automatically prevented if: (1) The frequency-hopping mode fails to distribute the JTIDS...

  19. Surfactants in lubrication – Recent developments

    USDA-ARS?s Scientific Manuscript database

    Lubricants are used in a wide range of industries and applications including: manufacturing (stamping, grinding, drilling, rolling, etc.,); transportation (e.g., engine oils, gear oils, transmission fluids, greases etc.); mining and construction (e.g., hydraulic fluids); medical and personal care (e...

  20. Laboratory Evaluation of Light Obscuration Particle Counter Contamination Limits for Aviation Fuel

    DTIC Science & Technology

    2015-11-01

    diesel product for ground use (1). At a minimum free water and particulate by color (as specified in the appendix of ASTM D2276) are checked daily...used in the hydraulics/hydraulic fluid industry. In 1999 ISO adopted ISO 11171 Hydraulic fluid power — Calibration of automatic particle counters...for liquids, replacing ISO 4402, as an international standard for the calibration of liquid particle counters giving NIST traceability to particle

  1. Light Obscuration Particle Counter Fuel Contamination Limits

    DTIC Science & Technology

    2015-10-08

    or up to 10 mg/L for product used as a diesel product for ground use (1). At a minimum free water and particulate by color (as specified in the...contamination is frequently used in the hydraulics/hydraulic fluid industry. In 1999 ISO adopted ISO 11171 Hydraulic fluid power — Calibration of automatic...particle counters for liquids, replacing ISO 4402, as an international standard for the calibration of liquid particle counters giving NIST

  2. Experimental transmission of enzootic intranasal tumors of goats.

    PubMed

    De las Heras, M; García de Jalón, J A; Minguijón, E; Gray, E W; Dewar, P; Sharp, J M

    1995-01-01

    The successful experimental transmission of enzootic intranasal tumor (EIT) from goat to goat is described. Ten kids, less than 48 hours old, from a flock free of the disease and seronegative for ruminant lentiviruses were inoculated intranasally or intrasinusally with either nasal fluid from goats with naturally occurring EIT or EIT retrovirus concentrated from such fluids. EIT was induced in three kids after 12-24 months. The EIT retrovirus was demonstrated in tumor material from each of the three kids by western blotting and electron microscopy. All kids were seronegative for ruminant lentiviruses.

  3. Interface Control Document for the EMPACT Module that Estimates Electric Power Transmission System Response to EMP-Caused Damage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Werley, Kenneth Alan; Mccown, Andrew William

    The EPREP code is designed to evaluate the effects of an Electro-Magnetic Pulse (EMP) on the electric power transmission system. The EPREP code embodies an umbrella framework that allows a user to set up analysis conditions and to examine analysis results. The code links to three major physics/engineering modules. The first module describes the EM wave in space and time. The second module evaluates the damage caused by the wave on specific electric power (EP) transmission system components. The third module evaluates the consequence of the damaged network on its (reduced) ability to provide electric power to meet demand. Thismore » third module is the focus of the present paper. The EMPACT code serves as the third module. The EMPACT name denotes EMP effects on Alternating Current Transmission systems. The EMPACT algorithms compute electric power transmission network flow solutions under severely damaged network conditions. Initial solutions are often characterized by unacceptible network conditions including line overloads and bad voltages. The EMPACT code contains algorithms to adjust optimally network parameters to eliminate network problems while minimizing outages. System adjustments include automatically adjusting control equipment (generator V control, variable transformers, and variable shunts), as well as non-automatic control of generator power settings and minimal load shedding. The goal is to evaluate the minimal loss of customer load under equilibrium (steady-state) conditions during peak demand.« less

  4. Method and system for spatial data input, manipulation and distribution via an adaptive wireless transceiver

    NASA Technical Reports Server (NTRS)

    Wang, Ray (Inventor)

    2009-01-01

    A method and system for spatial data manipulation input and distribution via an adaptive wireless transceiver. The method and system include a wireless transceiver for automatically and adaptively controlling wireless transmissions using a Waveform-DNA method. The wireless transceiver can operate simultaneously over both the short and long distances. The wireless transceiver is automatically adaptive and wireless devices can send and receive wireless digital and analog data from various sources rapidly in real-time via available networks and network services.

  5. TV audio and video on the same channel

    NASA Technical Reports Server (NTRS)

    Hopkins, J. B.

    1979-01-01

    Transmitting technique adds audio to video signal during vertical blanking interval. SIVI (signal in the vertical interval) is used by TV networks and stations to transmit cuing and automatic-switching tone signals to augment automatic and manual operations. It can also be used to transmit one-way instructional information, such as bulletin alerts, program changes, and commercial-cutaway aural cues from the networks to affiliates. Additonally, it can be used as extra sound channel for second-language transmission to biligual stations.

  6. Automatic generation of pictorial transcripts of video programs

    NASA Astrophysics Data System (ADS)

    Shahraray, Behzad; Gibbon, David C.

    1995-03-01

    An automatic authoring system for the generation of pictorial transcripts of video programs which are accompanied by closed caption information is presented. A number of key frames, each of which represents the visual information in a segment of the video (i.e., a scene), are selected automatically by performing a content-based sampling of the video program. The textual information is recovered from the closed caption signal and is initially segmented based on its implied temporal relationship with the video segments. The text segmentation boundaries are then adjusted, based on lexical analysis and/or caption control information, to account for synchronization errors due to possible delays in the detection of scene boundaries or the transmission of the caption information. The closed caption text is further refined through linguistic processing for conversion to lower- case with correct capitalization. The key frames and the related text generate a compact multimedia presentation of the contents of the video program which lends itself to efficient storage and transmission. This compact representation can be viewed on a computer screen, or used to generate the input to a commercial text processing package to generate a printed version of the program.

  7. Gas turbine engines and transmissions for bus demonstration program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nigro, D.N.

    1981-11-01

    This final report is to fulfill the contractural requirements of Contract DE-AC02-78CS54867 which required the delivery of 11 Allison GT 404-4 Industrial Gas Turbine Engines and five HT740CT and six V730CT Allison Automatic Transmissions for the Greyhound and Transit Coaches, respectively. In addition, software items such as cost reports, technical reports, installation drawings, acceptance test data and parts lists were required. Engine and transmission deliveries were completed with shipment of the last power package on 11 April 1980. Software items were submitted when required during the performance period of this contract.

  8. Research in Parallel Algorithms and Software for Computational Aerosciences

    DOT National Transportation Integrated Search

    1996-04-01

    Phase I is complete for the development of a Computational Fluid Dynamics : with automatic grid generation and adaptation for the Euler : analysis of flow over complex geometries. SPLITFLOW, an unstructured Cartesian : grid code developed at Lockheed...

  9. Validation of a computerized technique for automatically tracking and measuring the inferior vena cava in ultrasound imagery.

    PubMed

    Bellows, Spencer; Smith, Jordan; Mcguire, Peter; Smith, Andrew

    2014-01-01

    Accurate resuscitation of the critically-ill patient using intravenous fluids and blood products is a challenging, time sensitive task. Ultrasound of the inferior vena cava (IVC) is a non-invasive technique currently used to guide fluid administration, though multiple factors such as variable image quality, time, and operator skill challenge mainstream acceptance. This study represents a first attempt to develop and validate an algorithm capable of automatically tracking and measuring the IVC compared to human operators across a diverse range of image quality. Minimal tracking failures and high levels of agreement between manual and algorithm measurements were demonstrated on good quality videos. Addressing problems such as gaps in the vessel wall and intra-lumen speckle should result in improved performance in average and poor quality videos. Semi-automated measurement of the IVC for the purposes of non-invasive estimation of circulating blood volume poses challenges however is feasible.

  10. Transmission loss of double panels filled with porogranular materials.

    PubMed

    Chazot, Jean-Daniel; Guyader, Jean-Louis

    2009-12-01

    Sound transmission through hollow structures found its interest in several industrial domains such as building acoustics, automotive industry, and aeronautics. However, in practice, hollow structures are often filled with porous materials to improve acoustic properties without adding an excessive mass. Recently a lot of interest arises for granular materials of low density that can be an alternative to standard absorbing materials. This paper aims to predict vibro-acoustic behavior of double panels filled with porogranular materials by using the patch-mobility method recently published. Biot's theory is a basic tool for the description of porous material but is quite difficult to use in practice, mostly because of the solid phase characterization. The original simplified Biot's model (fluid-fluid model) for porogranular material permitting a considerable reduction in data necessary for calculation has been recently published. The aim of the present paper is to propose a model to predict sound transmission through a double panel filled with a porogranular material. The method is an extension of a previous paper to take into account the porogranular material through fluid-fluid Biot's model. After a global overview of the method, the case of a double panel filled with expanded polystyrene beads is studied and a comparison with measurements is realized.

  11. Evaluation of Automobile Drivetrain Components to Improve Fuel Economy

    DOT National Transportation Integrated Search

    1979-03-01

    Wide ratio range automatic transmissions with lockup torque converters could be in production by the early 1980's. In order to evaluate their impact upon fuel economy, emissions, driveability, acceleration, and durability, four 1975 Chrysler automobi...

  12. A 735 kV shunt reactors automatic switching system for Hydro-Quebec network

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernard, S.; Trudel, G.; Scott, G.

    1996-11-01

    In recent years, Hydro-Quebec has undertaken a major program to upgrade the reliability of its transmission system. Much efforts have been directed toward increasing the system`s capacity to withstand extreme contingencies, usually caused by multiple incidents or the successive tripping of transmission lines. In order to counter such events, Hydro-Quebec has adopted a defensive scheme. Based entirely on automatic action, this scheme will mainly rely on: a 735 kV shunt reactor switching system (called MAIS); a generation rejection and/or remote load-shedding system (called RPTC); an underfrequency load-shedding system. The MAIS system, which is the subject of this paper, will bemore » implemented in 22 substations and is required to control voltage on the system after a severe event. Each MAIS system, acting locally, is entirely independent and will close or trip shunt reactors in response to local conditions.« less

  13. Automatic control of electric thermal storage (heat) under real-time pricing. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daryanian, B.; Tabors, R.D.; Bohn, R.E.

    1995-01-01

    Real-time pricing (RTP) can be used by electric utilities as a control signal for responsive demand-side management (DSM) programs. Electric thermal storage (ETS) systems in buildings provide the inherent flexibility needed to take advantage of variations in prices. Under RTP, optimal performance for ETS operations is achieved under market conditions where reductions in customers` costs coincide with the lowering of the cost of service for electric utilities. The RTP signal conveys the time-varying actual marginal cost of the electric service to customers. The RTP rate is a combination of various cost components, including marginal generation fuel and maintenance costs, marginalmore » costs of transmission and distribution losses, and marginal quality of supply and transmission costs. This report describes the results of an experiment in automatic control of heat storage systems under RTP during the winter seasons of 1989--90 and 1990--91.« less

  14. Evaluation of Yersinia pestis Transmission Pathways for Sylvatic Plague in Prairie Dog Populations in the Western U.S.

    PubMed

    Richgels, Katherine L D; Russell, Robin E; Bron, Gebbiena M; Rocke, Tonie E

    2016-06-01

    Sylvatic plague, caused by the bacterium Yersinia pestis, is periodically responsible for large die-offs in rodent populations that can spillover and cause human mortalities. In the western US, prairie dog populations experience nearly 100% mortality during plague outbreaks, suggesting that multiple transmission pathways combine to amplify plague dynamics. Several alternate pathways in addition to flea vectors have been proposed, such as transmission via direct contact with bodily fluids or inhalation of infectious droplets, consumption of carcasses, and environmental sources of plague bacteria, such as contaminated soil. However, evidence supporting the ability of these proposed alternate pathways to trigger large-scale epizootics remains elusive. Here we present a short review of potential plague transmission pathways and use an ordinary differential equation model to assess the contribution of each pathway to resulting plague dynamics in black-tailed prairie dogs (Cynomys ludovicianus) and their fleas (Oropsylla hirsuta). Using our model, we found little evidence to suggest that soil contamination was capable of producing plague epizootics in prairie dogs. However, in the absence of flea transmission, direct transmission, i.e., contact with bodily fluids or inhalation of infectious droplets, could produce enzootic dynamics, and transmission via contact with or consumption of carcasses could produce epizootics. This suggests that these pathways warrant further investigation.

  15. Evaluation of Yersinia pestis transmission pathways for sylvatic plague in prairie dog populations in the western U.S.

    USGS Publications Warehouse

    Richgels, Katherine L. D.; Russell, Robin E.; Bron, Gebbiena; Rocke, Tonie E.

    2016-01-01

    Sylvatic plague, caused by the bacterium Yersinia pestis, is periodically responsible for large die-offs in rodent populations that can spillover and cause human mortalities. In the western US, prairie dog populations experience nearly 100% mortality during plague outbreaks, suggesting that multiple transmission pathways combine to amplify plague dynamics. Several alternate pathways in addition to flea vectors have been proposed, such as transmission via direct contact with bodily fluids or inhalation of infectious droplets, consumption of carcasses, and environmental sources of plague bacteria, such as contaminated soil. However, evidence supporting the ability of these proposed alternate pathways to trigger large-scale epizootics remains elusive. Here we present a short review of potential plague transmission pathways and use an ordinary differential equation model to assess the contribution of each pathway to resulting plague dynamics in black-tailed prairie dogs (Cynomys ludovicianus) and their fleas (Oropsylla hirsuta). Using our model, we found little evidence to suggest that soil contamination was capable of producing plague epizootics in prairie dogs. However, in the absence of flea transmission, direct transmission, i.e., contact with bodily fluids or inhalation of infectious droplets, could produce enzootic dynamics, and transmission via contact with or consumption of carcasses could produce epizootics. This suggests that these pathways warrant further investigation.

  16. The Etiology, Incidence, and Impact of Preservation Fluid Contamination during Liver Transplantation

    PubMed Central

    Lladó, Laura; Vila, Marina; Baliellas, Carme; Tubau, Fe; Sabé, Núria; Fabregat, Joan; Carratalà, Jordi

    2016-01-01

    The role of contaminated preservation fluid in the development of infection after liver transplantation has not been fully elucidated. To assess the incidence and etiology of contaminated preservation fluid and determine its impact on the subsequent development of infection after liver transplantation, we prospectively studied 50 consecutive liver transplants, and cultured the following samples in each instance: preservation fluid (immediately before and at the end of the back-table procedure, and just before implantation), blood, and bile from the donor, and ascitic fluid from the recipient. When any culture was positive, blood cultures were obtained and targeted antimicrobial therapy was started. We found that the incidence of contaminated preservation fluid was 92% (46 of 50 cases of liver transplantation per year), but only 28% (14/50) were contaminated by recognized pathogens. Blood and bile cultures from the donor were positive in 28% and 6% respectively, whereas ascitic fluid was positive in 22%. The most frequently isolated microorganisms were coagulase-negative staphylococci. In nine cases, the microorganisms isolated from the preservation fluid concurred with those grown from the donor blood cultures, and in one case, the isolate matched with the one obtained from bile culture. No liver transplant recipient developed an infection due to the transmission of an organism isolated from the preservation fluid. Our findings indicate that contamination of the preservation fluid is frequent in liver transplantation, and it is mainly caused by saprophytic skin flora. Transmission of infection is low, particularly among those recipients given targeted antimicrobial treatment for organisms isolated in the preservation fluid. PMID:27513941

  17. The Etiology, Incidence, and Impact of Preservation Fluid Contamination during Liver Transplantation.

    PubMed

    Oriol, Isabel; Lladó, Laura; Vila, Marina; Baliellas, Carme; Tubau, Fe; Sabé, Núria; Fabregat, Joan; Carratalà, Jordi

    2016-01-01

    The role of contaminated preservation fluid in the development of infection after liver transplantation has not been fully elucidated. To assess the incidence and etiology of contaminated preservation fluid and determine its impact on the subsequent development of infection after liver transplantation, we prospectively studied 50 consecutive liver transplants, and cultured the following samples in each instance: preservation fluid (immediately before and at the end of the back-table procedure, and just before implantation), blood, and bile from the donor, and ascitic fluid from the recipient. When any culture was positive, blood cultures were obtained and targeted antimicrobial therapy was started. We found that the incidence of contaminated preservation fluid was 92% (46 of 50 cases of liver transplantation per year), but only 28% (14/50) were contaminated by recognized pathogens. Blood and bile cultures from the donor were positive in 28% and 6% respectively, whereas ascitic fluid was positive in 22%. The most frequently isolated microorganisms were coagulase-negative staphylococci. In nine cases, the microorganisms isolated from the preservation fluid concurred with those grown from the donor blood cultures, and in one case, the isolate matched with the one obtained from bile culture. No liver transplant recipient developed an infection due to the transmission of an organism isolated from the preservation fluid. Our findings indicate that contamination of the preservation fluid is frequent in liver transplantation, and it is mainly caused by saprophytic skin flora. Transmission of infection is low, particularly among those recipients given targeted antimicrobial treatment for organisms isolated in the preservation fluid.

  18. Flow rate measurement in a volume

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Galvez, Cristhian

    A system for measuring flow rate within a volume includes one or more transmission devices that transmit one or more signals through fluid contained within the volume. The volume may be bounded, at least in part, by an outer structure and by an object at least partially contained within the outer structure. A transmission device located at a first location of the outer structure transmits a first signal to a second location of the outer structure. A second signal is transmitted through the fluid from the second location to a third location of the outer structure. The flow rate ofmore » the fluid within the volume may be determined based, at least in part, on the time of flight of both the first signal and the second signal.« less

  19. Loaded Transducer Fpr Downhole Drilling Component

    DOEpatents

    Hall, David R.; Hall, H. Tracy; Pixton, David; Dahlgren, Scott; Sneddon, Cameron; Briscoe, Michael; Fox, Joe

    2005-07-05

    A robust transmission element for transmitting information between downhole tools, such as sections of drill pipe, in the presence of hostile environmental conditions, such as heat, dirt, rocks, mud, fluids, lubricants, and the like. The transmission element maintains reliable connectivity between transmission elements, thereby providing an uninterrupted flow of information between drill string components. A transmission element is mounted within a recess proximate a mating surface of a downhole drilling component, such as a section of drill pipe. To close gaps present between transmission elements, transmission elements may be biased with a "spring force," urging them closer together.

  20. Loaded transducer for downhole drilling components

    DOEpatents

    Hall, David R.; Hall, Jr., H. Tracy; Pixton, David S.; Briscoe, Michael A.; Dahlgren, Scott Steven; Fox, Joe; Sneddon, Cameron

    2006-02-21

    A robust transmission element for transmitting information between downhole tools, such as sections of drill pipe, in the presence of hostile environmental conditions, such as heat, dirt, rocks, mud, fluids, lubricants, and the like. The transmission element maintains reliable connectivity between transmission elements, thereby providing an uninterrupted flow of information between drill string components. A transmission element is mounted within a recess proximate a mating surface of a downhole drilling component, such as a section of drill pipe. To close gaps present between transmission elements, transmission elements may be biased with a "spring force, urging them closer together."

  1. Electronic Dipstick

    NASA Technical Reports Server (NTRS)

    1991-01-01

    Lake-Tronic's Negative Thermistor Coefficients (NTC) prevent engine nozzles in the Space Shuttle Orbiter from swinging from side to side changing the thrust line. This technology has been adapted to an Electronik Dipstick, used to automatically monitor automotive fluid levels. NTC's are placed at predetermined levels in the dipstick and heated. Contact with fluids dissipates the heat creating a resistance change, which is analyzed by a microprocessor. Installation is simple, and additional applications are under consideration. This product is no longer manufactured.

  2. EVA Metro Sedan electric-propulsion system: test and evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reimers, E.

    1979-09-01

    The procedure and results of the performance evaluation of the EVA Metro Sedan (car No. 1) variable speed dc chopper motor drive and its three speed automatic transmission are presented. The propulsion system for a battery powered vehicle manufactured by Electric Vehicle Associates, Valley View, Ohio, was removed from the vehicle, mounted on the programmable electric dynamometer test facility and evaluated with the aid of a hp 3052A Data Acquisition System. Performance data for the automatic transmission, the solid state dc motor speed controller, and the dc motor in the continuous and pulsating dc power mode, as derived on themore » dynamometer test facility, as well as the entire propulsion system are given. This concept and the system's components were evaluated in terms of commercial applicability, maintainability, and energy utility to establish a design base for the further development of this system or similar propulsion drives. The propulsion system of the EVA Metro Sedan is powered by sixteen 6-volt traction batteries, Type EV 106 (Exide Battery Mfg. Co.). A thyristor controlled cable form Pulsomatic Mark 10 controller, actuated by a foot throttle, controls the voltage applied to a dc series field motor, rated at 10 hp at 3800 rpm (Baldor Electric Co.). Gear speed reduction to the wheel is accomplished by the original equipment three speed automatic transmission with torque converter (Renault 12 Sedan). The brake consists of a power-assisted, hydraulic braking system with front wheel disk and rear drum. An ability to recuperate electric energy with subsequent storage in the battery power supply is not provided.« less

  3. Effect of middle ear fluid on sound transmission and auditory brainstem response in guinea pigs.

    PubMed

    Guan, Xiying; Gan, Rong Z

    2011-07-01

    Combined measurements of middle ear transfer function and auditory brainstem response (ABR) in live guinea pigs with middle ear effusion (MEE) are reported in this paper. The MEE model was created by injecting saline into the middle ear cavity. Vibrations of the tympanic membrane (TM), the tip of the incus, and the round window membrane (RWM) were measured with a laser vibrometer at frequencies of 0.2-40 kHz when the middle ear fluid increased from 0 to 0.2 ml (i.e., full fill of the cavity). The click and pure tone ABRs were recorded as the middle ear fluid increased. Fluid introduction reduced mobility of the TM, incus and RWM mainly at high frequencies (f > 1 kHz). The magnitude of this reduction was related to the volume of fluid. The displacement transmission ratio of the TM to incus varied with frequency and fluid level. The volume displacement ratio of the oval window to round window was approximately 1.0 over most frequencies. Elevation of ABR thresholds and prolongation of ABR latencies were observed as fluid level increased. Reduction of TM displacement correlated well with elevation of ABR threshold at 0.5-8 kHz. Alterations in the ratio of ossicular displacements before and after fluid induction are consistent with fluid-induced changes in complex ossicular motions. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Application of a movable active vibration control system on a floating raft

    NASA Astrophysics Data System (ADS)

    Wang, Zhen; Mak, Cheuk Ming

    2018-02-01

    This paper presents a theoretical study of an inertial actuator connected to an accelerometer by a local feedback loop for active vibration control on a floating raft. On the criterion of the minimum power transmission from the vibratory machines to the flexible foundation in the floating raft, the best mounting positions for the inertial actuator on the intermediate mass of the floating raft are investigated. Simulation results indicate that the best mounting positions for the inertial actuator vary with frequency. To control time-varying excitations of vibratory machines on a floating raft effectively, an automatic control system based on real-time measurement of a cost function and automatically searching the best mounting position of the inertial actuator is proposed. To the best of our knowledge, it is the first time that an automatic control system is proposed to move an actuator automatically for controlling a time-varying excitation.

  5. Ion transfer from an atmospheric pressure ion funnel into a mass spectrometer with different interface options: Simulation-based optimization of ion transmission efficiency.

    PubMed

    Mayer, Thomas; Borsdorf, Helko

    2016-02-15

    We optimized an atmospheric pressure ion funnel (APIF) including different interface options (pinhole, capillary, and nozzle) regarding a maximal ion transmission. Previous computer simulations consider the ion funnel itself and do not include the geometry of the following components which can considerably influence the ion transmission into the vacuum stage. Initially, a three-dimensional computer-aided design (CAD) model of our setup was created using Autodesk Inventor. This model was imported to the Autodesk Simulation CFD program where the computational fluid dynamics (CFD) were calculated. The flow field was transferred to SIMION 8.1. Investigations of ion trajectories were carried out using the SDS (statistical diffusion simulation) tool of SIMION, which allowed us to evaluate the flow regime, pressure, and temperature values that we obtained. The simulation-based optimization of different interfaces between an atmospheric pressure ion funnel and the first vacuum stage of a mass spectrometer require the consideration of fluid dynamics. The use of a Venturi nozzle ensures the highest level of transmission efficiency in comparison to capillaries or pinholes. However, the application of radiofrequency (RF) voltage and an appropriate direct current (DC) field leads to process optimization and maximum ion transfer. The nozzle does not hinder the transfer of small ions. Our high-resolution SIMION model (0.01 mm grid unit(-1) ) under consideration of fluid dynamics is generally suitable for predicting the ion transmission through an atmospheric-vacuum system for mass spectrometry and enables the optimization of operational parameters. A Venturi nozzle inserted between the ion funnel and the mass spectrometer permits maximal ion transmission. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  6. Dynamic Information and Library Processing.

    ERIC Educational Resources Information Center

    Salton, Gerard

    This book provides an introduction to automated information services: collection, analysis, classification, storage, retrieval, transmission, and dissemination. An introductory chapter is followed by an overview of mechanized processes for acquisitions, cataloging, and circulation. Automatic indexing and abstracting methods are covered, followed…

  7. Computer automation for feedback system design

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Mathematical techniques and explanations of various steps used by an automated computer program to design feedback systems are summarized. Special attention was given to refining the automatic evaluation suboptimal loop transmission and the translation of time to frequency domain specifications.

  8. First- and Second-Order Sensitivity Analysis of a P-Version Finite Element Equation Via Automatic Differentiation

    NASA Technical Reports Server (NTRS)

    Hou, Gene

    1998-01-01

    Sensitivity analysis is a technique for determining derivatives of system responses with respect to design parameters. Among many methods available for sensitivity analysis, automatic differentiation has been proven through many applications in fluid dynamics and structural mechanics to be an accurate and easy method for obtaining derivatives. Nevertheless, the method can be computational expensive and can require a high memory space. This project will apply an automatic differentiation tool, ADIFOR, to a p-version finite element code to obtain first- and second- order then-nal derivatives, respectively. The focus of the study is on the implementation process and the performance of the ADIFOR-enhanced codes for sensitivity analysis in terms of memory requirement, computational efficiency, and accuracy.

  9. 2D automatic body-fitted structured mesh generation using advancing extraction method

    NASA Astrophysics Data System (ADS)

    Zhang, Yaoxin; Jia, Yafei

    2018-01-01

    This paper presents an automatic mesh generation algorithm for body-fitted structured meshes in Computational Fluids Dynamics (CFD) analysis using the Advancing Extraction Method (AEM). The method is applicable to two-dimensional domains with complex geometries, which have the hierarchical tree-like topography with extrusion-like structures (i.e., branches or tributaries) and intrusion-like structures (i.e., peninsula or dikes). With the AEM, the hierarchical levels of sub-domains can be identified, and the block boundary of each sub-domain in convex polygon shape in each level can be extracted in an advancing scheme. In this paper, several examples were used to illustrate the effectiveness and applicability of the proposed algorithm for automatic structured mesh generation, and the implementation of the method.

  10. Single transmission line data acquisition system

    DOEpatents

    Fasching, George E.

    1984-01-01

    A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensors monitor specific process variables and transmit measurement values over the single transmission line to a master station when addressed by the master station. Power for all remote stations (up to 980) is provided by driving the line with constant voltage supplied from the master station and automatically maintained independent of the number of remote stations directly connected to the line. The transmission line can be an RG-62 coaxial cable with lengths up to about 10,000 feet with branches up to 500 feet. The remote stations can be attached randomly along the line. The remote stations can be scanned at rates up to 980 channels/second.

  11. Gas turbine engines and transmissions for bus demonstration programs. Technical status report, 30 April 1979-31 July 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nigro, D.N.

    1979-07-01

    The quarterly status report covers the period from 30 April 1979 through 31 July 1979 and is a summary of DDA activities for the effort performed on the procurement and delivery of eleven (11) Allison GT 404-4 gas turbine engines and five (5) HT740CT and six (6) V730CT Allison automatic transmissions and the required associated software. The contract requires the delivery of eleven (11) Allison GT 404-4 Industrial Gas Turbine Engines and five (5) HT740CT and six (6) V730CT Allison Automatic Transmissions for the Greyhound and Transit Coaches, respectively. In addition, software items such as cost reports, technical reports, installationmore » drawings, acceptance test data and parts lists are required. A recent decision by the DOE will modify the build configuration for the last four (4) Transit Coach engines. It was decided by the DOE at a meeting in Washington, DC on March 28, 1979 with representatives from DDA, NASA/LeRC, JPL and Booz-Allen and Hamilton that these engines will be built with ceramic regenerators. (TFD)« less

  12. Infectious Prions in the Saliva and Blood of Deer with Chronic Wasting Disease

    NASA Astrophysics Data System (ADS)

    Mathiason, Candace K.; Powers, Jenny G.; Dahmes, Sallie J.; Osborn, David A.; Miller, Karl V.; Warren, Robert J.; Mason, Gary L.; Hays, Sheila A.; Hayes-Klug, Jeanette; Seelig, Davis M.; Wild, Margaret A.; Wolfe, Lisa L.; Spraker, Terry R.; Miller, Michael W.; Sigurdson, Christina J.; Telling, Glenn C.; Hoover, Edward A.

    2006-10-01

    A critical concern in the transmission of prion diseases, including chronic wasting disease (CWD) of cervids, is the potential presence of prions in body fluids. To address this issue directly, we exposed cohorts of CWD-naïve deer to saliva, blood, or urine and feces from CWD-positive deer. We found infectious prions capable of transmitting CWD in saliva (by the oral route) and in blood (by transfusion). The results help to explain the facile transmission of CWD among cervids and prompt caution concerning contact with body fluids in prion infections.

  13. Well-posed and stable transmission problems

    NASA Astrophysics Data System (ADS)

    Nordström, Jan; Linders, Viktor

    2018-07-01

    We introduce the notion of a transmission problem to describe a general class of problems where different dynamics are coupled in time. Well-posedness and stability are analysed for continuous and discrete problems using both strong and weak formulations, and a general transmission condition is obtained. The theory is applied to the coupling of fluid-acoustic models, multi-grid implementations, adaptive mesh refinements, multi-block formulations and numerical filtering.

  14. Membrane Transport Phenomena (MTP)

    NASA Technical Reports Server (NTRS)

    Mason, Larry W.

    1996-01-01

    The development of the seal between the membrane and the Fluid Optical Cells (FOC) has been a high priority activity. This seal occurs at an interface in the instrument where three key functions must be realized: (1) physical membrane support, (2) fluid sealing, and (3) unobscured optical transmission.

  15. Control of optical transport parameters of 'porous medium – supercritical fluid' systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zimnyakov, D A; Ushakova, O V; Yuvchenko, S A

    2015-11-30

    The possibility of controlling optical transport parameters (in particular, transport scattering coefficient) of porous systems based on polymer fibres, saturated with carbon dioxide in different phase states (gaseous, liquid and supercritical) has been experimentally studied. An increase in the pressure of the saturating medium leads to a rise of its refractive index and, correspondingly, the diffuse-transmission coefficient of the system due to the decrease in the transport scattering coefficient. It is shown that, in the case of subcritical saturating carbon dioxide, the small-angle diffuse transmission of probed porous layers at pressures close to the saturated vapour pressure is determined bymore » the effect of capillary condensation in pores. The immersion effect in 'porous medium – supercritical fluid' systems, where the fluid pressure is used as a control parameter, is considered. The results of reconstructing the values of transport scattering coefficient of probed layers for different refractive indices of a saturating fluid are presented. (radiation scattering)« less

  16. Automatic brightness control of laser spot vision inspection system

    NASA Astrophysics Data System (ADS)

    Han, Yang; Zhang, Zhaoxia; Chen, Xiaodong; Yu, Daoyin

    2009-10-01

    The laser spot detection system aims to locate the center of the laser spot after long-distance transmission. The accuracy of positioning laser spot center depends very much on the system's ability to control brightness. In this paper, an automatic brightness control system with high-performance is designed using the device of FPGA. The brightness is controlled by combination of auto aperture (video driver) and adaptive exposure algorithm, and clear images with proper exposure are obtained under different conditions of illumination. Automatic brightness control system creates favorable conditions for positioning of the laser spot center later, and experiment results illuminate the measurement accuracy of the system has been effectively guaranteed. The average error of the spot center is within 0.5mm.

  17. Transmissivity interpolation using Fluid Flow Log data at different depth level in Liwa Aquifer, UAE.

    NASA Astrophysics Data System (ADS)

    Gülşen, Esra; Kurtulus, Bedri; Necati Yaylim, Tolga; Avsar, Ozgur

    2017-04-01

    In groundwater studies, quantification and detection of fluid flows in borehole is an important part of assessment aquifer characteristic at different depths. Monitoring wells disturbs the natural flow field and this disturbance creates different flow paths to an aquifer. Vertical flow fluid analyses are one of the important techniques to deal with the detection and quantification of these vertical flows in borehole/monitoring wells. Liwa region is located about 146 km to the south west of Abu Dhabi city and about 36 km southwest of Madinat Zayed. SWSR (Strategic Water Storage & Recovery Project) comprises three Schemes (A, B and C) and each scheme contains an infiltration basin in the center, 105 recovery wells, 10 clusters and each cluster comprises 3 monitoring wells with different depths; shallow ( 50 m), intermediate ( 75 m) and deep ( 100 m). The scope of this study is to calculate the transmissivity values at different depth and evaluate the Fluid Flow Log (FFL) data for Scheme A (105 recovery wells) in order to understand the aquifer characteristic at different depths. The transmissivity values at different depth levels are calculated using Razack and Huntley (1991) equation for vertical flow rates of 30 m3 /h, 60 m3 /h, 90 m3 /h, 120 m3 /h and then Empirical Bayesian Kriging is used for interpolation in Scheme A using ArcGIS 10.2 software. FFL are drawn by GeODin software. Derivative analysis of fluid flow data are done by Microsoft Office: Excel software. All statistical analyses are calculated by IBMSPSS software. The interpolation results show that the transmissivity values are higher at the top of the aquifer. In other word, the aquifer is found more productive at the upper part of the Liwa aquifer. We are very grateful for financial support and providing us the data to ZETAS Dubai Inc.

  18. Basal Ganglia Dopamine-gamma-Aminobutyric Acid-Acetylcholine Interaction in Organophosphate-Induced Neurotoxicity. Appendices

    DTIC Science & Technology

    1982-12-01

    Animals were maintained ad llbltua on standard laboratory chow and tap water and were housed in a room with automatic 12 hour light and dark cycles and...supernatant fluid was centrl- fuged at 20,000 x g for 20 min to obtain a crude mitochondria ! pellet. The crude mitochondrlal pellet was resuspended...chow and tap water and wer- housed in a room with automatic 12 hour light and dark cycles and temperature set at 25.5 ± 1.8°C. DUsopropylfli’oro

  19. Simplified flexible-PON upstream transmission using pulse position modulation at ONU and DSP-enabled soft-combining at OLT for adaptive link budgets.

    PubMed

    Liu, Xiang; Effenberger, Frank; Chand, Naresh

    2015-03-09

    We demonstrate a flexible modulation and detection scheme for upstream transmission in passive optical networks using pulse position modulation at optical network unit, facilitating burst-mode detection with automatic decision threshold tracking, and DSP-enabled soft-combining at optical line terminal. Adaptive receiver sensitivities of -33.1 dBm, -36.6 dBm and -38.3 dBm at a bit error ratio of 10(-4) are respectively achieved for 2.5 Gb/s, 1.25 Gb/s and 625 Mb/s after transmission over a 20-km standard single-mode fiber without any optical amplification.

  20. Efficient Sparse Signal Transmission over a Lossy Link Using Compressive Sensing

    PubMed Central

    Wu, Liantao; Yu, Kai; Cao, Dongyu; Hu, Yuhen; Wang, Zhi

    2015-01-01

    Reliable data transmission over lossy communication link is expensive due to overheads for error protection. For signals that have inherent sparse structures, compressive sensing (CS) is applied to facilitate efficient sparse signal transmissions over lossy communication links without data compression or error protection. The natural packet loss in the lossy link is modeled as a random sampling process of the transmitted data, and the original signal will be reconstructed from the lossy transmission results using the CS-based reconstruction method at the receiving end. The impacts of packet lengths on transmission efficiency under different channel conditions have been discussed, and interleaving is incorporated to mitigate the impact of burst data loss. Extensive simulations and experiments have been conducted and compared to the traditional automatic repeat request (ARQ) interpolation technique, and very favorable results have been observed in terms of both accuracy of the reconstructed signals and the transmission energy consumption. Furthermore, the packet length effect provides useful insights for using compressed sensing for efficient sparse signal transmission via lossy links. PMID:26287195

  1. Pilot solar power plant

    NASA Astrophysics Data System (ADS)

    Wolf, D.

    A fully functionally efficient solar-thermal power plant (10 kW electric) was built. The operating principle of thermomechanical conversion of solar energy into mechanical or electrical energy is presented. The equipment is completely automatic. Flat plate collectors absorb solar energy and convert it into heat which is transmitted by water to a heat exchanger. A closed cycle machine uses the heat to boil a working fluid (C2C12F4). A screw, powered by gas expansion in the working fluid, converts mechanical energy into electrical energy.

  2. Application of semi-active RFID power meter in automatic verification pipeline and intelligent storage system

    NASA Astrophysics Data System (ADS)

    Chen, Xiangqun; Huang, Rui; Shen, Liman; chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Liu, Mouhai; Xu, Renheng

    2018-03-01

    In this paper, the semi-active RFID watt-hour meter is applied to automatic test lines and intelligent warehouse management, from the transmission system, test system and auxiliary system, monitoring system, realize the scheduling of watt-hour meter, binding, control and data exchange, and other functions, make its more accurate positioning, high efficiency of management, update the data quickly, all the information at a glance. Effectively improve the quality, efficiency and automation of verification, and realize more efficient data management and warehouse management.

  3. Simple Automatic File Exchange (SAFE) to Support Low-Cost Spacecraft Operation via the Internet

    NASA Technical Reports Server (NTRS)

    Baker, Paul; Repaci, Max; Sames, David

    1998-01-01

    Various issues associated with Simple Automatic File Exchange (SAFE) are presented in viewgraph form. Specific topics include: 1) Packet telemetry, Internet IP networks and cost reduction; 2) Basic functions and technical features of SAFE; 3) Project goals, including low-cost satellite transmission to data centers to be distributed via an Internet; 4) Operations with a replicated file protocol; 5) File exchange operation; 6) Ground stations as gateways; 7) Lessons learned from demonstrations and tests with SAFE; and 8) Feedback and future initiatives.

  4. Fiber optic fluid detector

    DOEpatents

    Angel, S.M.

    1987-02-27

    Particular gases or liquids are detected with a fiber optic element having a cladding or coating of a material which absorbs the fluid or fluids and which exhibits a change of an optical property, such as index of refraction, light transmissiveness or fluoresence emission, for example, in response to absorption of the fluid. The fluid is sensed by directing light into the fiber optic element and detecting changes in the light, such as exit angle changes for example, that result from the changed optical property of the coating material. The fluid detector may be used for such purposes as sensing toxic or explosive gases in the atmosphere, measuring ground water contamination or monitoring fluid flows in industrial processes, among other uses. 10 figs.

  5. Nanoscale Surface Plasmonics Sensor With Nanofluidic Control

    NASA Technical Reports Server (NTRS)

    Wei, Jianjun; Singhal, Sameer; Waldeck, David H.; Kofke, Matthew

    2013-01-01

    Conventional quantitative protein assays of bodily fluids typically involve multiple steps to obtain desired measurements. Such methods are not well suited for fast and accurate assay measurements in austere environments such as spaceflight and in the aftermath of disasters. Consequently, there is a need for a protein assay technology capable of routinely monitoring proteins in austere environments. For example, there is an immediate need for a urine protein assay to assess astronaut renal health during spaceflight. The disclosed nanoscale surface plasmonics sensor provides a core detection method that can be integrated to a lab-on-chip device that satisfies the unmet need for such a protein assay technology. Assays based upon combinations of nanoholes, nanorings, and nanoslits with transmission surface plasmon resonance (SPR) are used for assays requiring extreme sensitivity, and are capable of detecting specific analytes at concentrations as low as picomole to femtomole level in well-controlled environments. The device operates in a transmission mode configuration in which light is directed at one planar surface of the array, which functions as an optical aperture. The incident light induces surface plasmon light transmission from the opposite surface of the array. The presence of a target analyte is detected by changes in the spectrum of light transmitted by the array when a target analyte induces a change in the refractive index of the fluid within the nanochannels. This occurs, for example, when a target analyte binds to a receptor fixed to the walls of the nanochannels in the array. Independent fluid handling capability for individual nanoarrays on a nanofluidic chip containing a plurality of nanochannel arrays allows each array to be used to sense a different target analyte and/or for paired arrays to analyze control and test samples simultaneously in parallel. The present invention incorporates transmission mode nanoplasmonics and nanofluidics into a single, microfluidically controlled device. The device comprises one or more arrays of aligned nanochannels that are in fluid communication with inflowing and outflowing fluid handling manifolds that control the flow of fluid through the arrays. The array acts as an aperture in a plasmonic sensor. Fluid, in the form of a liquid or a gas and comprising a sample for analysis, is moved from an inlet manifold through the nanochannel array, and out through an exit manifold. The fluid may also contain a reagent used to modify the interior surfaces of the nanochannels, and/or a reagent required for the detection of an analyte.

  6. Bottlenecks in HIV-1 transmission: insights from the study of founder viruses.

    PubMed

    Joseph, Sarah B; Swanstrom, Ronald; Kashuba, Angela D M; Cohen, Myron S

    2015-07-01

    HIV-1 infection typically results from the transmission of a single viral variant, the transmitted/founder (T/F) virus. Studies of these HIV-1 variants provide critical information about the transmission bottlenecks and the selective pressures acting on the virus in the transmission fluid and in the recipient tissues. These studies reveal that T/F virus phenotypes are shaped by stochastic and selective forces that restrict transmission and may be targets for prevention strategies. In this Review, we highlight how studies of T/F viruses contribute to a better understanding of the biology of HIV-1 transmission and discuss how these findings affect HIV-1 prevention strategies.

  7. Quantify fluid saturation in fractures by light transmission technique and its application

    NASA Astrophysics Data System (ADS)

    Ye, S.; Zhang, Y.; Wu, J.

    2016-12-01

    The Dense Non-Aqueous Phase Liquids (DNAPLs) migration in transparent and rough fractures with variable aperture was studied experimentally using a light transmission technique. The migration of trichloroethylene (TCE) in variable-aperture fractures (20 cm wide x 32.5 cm high) showed that a TCE blob moved downward with snap-off events in four packs with apertures from 100 μm to 1000 μm, and that the pattern presented a single and tortuous cluster with many fingers in a pack with two apertures of 100 μm and 500 μm. The variable apertures in the fractures were measured by light transmission. A light intensity-saturation (LIS) model based on light transmission was used to quantify DNAPL saturation in the fracture system. Known volumes of TCE, were added to the chamber and these amounts were compared to the results obtained by LIS model. Strong correlation existed between results obtained based on LIS model and the known volumes of T CE. Sensitivity analysis showed that the aperture was more sensitive than parameter C2 of LIS model. LIS model was also used to measure dyed TCE saturation in air sparging experiment. The results showed that the distribution and amount of TCE significantly influenced the efficient of air sparging. The method developed here give a way to quantify fluid saturation in two-phase system in fractured medium, and provide a non-destructive, non-intrusive tool to investigate changes in DNAPL architecture and flow characteristics in laboratory experiments. Keywords: light transmission, fluid saturation, fracture, variable aperture AcknowledgementsFunding for this research from NSFC Project No. 41472212.

  8. The processing and transmission of EEG data

    NASA Technical Reports Server (NTRS)

    Schulze, A. E.

    1974-01-01

    Interest in sleep research was stimulated by the discovery of a number of physiological changes that occur during sleep and by the observed effects of sleep on physical and mental performance and status. The use of the relatively new methods of EEG measurement, transmission, and automatic scoring makes sleep analysis and categorization feasible. Sleep research involving the use of the EEG as a fundamental input has the potential of answering many unanswered questions involving physical and mental behavior, drug effects, circadian rhythm, and anesthesia.

  9. Electrorheological (ER) Fluids: A Research Needs Assessment

    DTIC Science & Technology

    1993-05-01

    transmission, and to reduce energy loss and damage due to vibration and oscillation. A large number and variety of ER devices have been invented; they are...suspension must be stabilized to prevent settling. Separation could cause loss of fluid performance, plugging of flow paths, and other problems...performa.ice of ER fluids, especially those containing water, can change with time as a result of component loss through evaporation at elevated use

  10. An automated full waveform logging system for high-resolution P-wave profiles in marine sediments

    NASA Astrophysics Data System (ADS)

    Breitzke, Monika; Spieβ, Volkhard

    1993-11-01

    An automated, PC-based logging system has been developed to investigate marine sediment cores by full waveform transmission seismograms. High-resolution P-wave velocity and amplitude attenuation profiles are simultaneously derived from the transmission data to characterize the acoustic properties of the sediment column. A pair of ultrasonic, piezoelectric wheel probes is used to generate and record the transmission signals travelling radially through the sediment core. Both unsplit and split cores are allowed. Mounted in a carriage driven by a stepping motor via a shaft the probes automatically move along the core liner, stopping at equidistant spacings to provide a quasi-continuous inspection of the core by the transmission data. The axial travel distance and the core diameter are determined by digital measuring tools. First arrivals are picked automatically from the transmission seismograms using either a threshold in the seismogram's envelope or a cross-correlation algorithm taking the ‘zero-offset’ signal of both wheel probes into account. Combined with the core diameter these first arrivals lead to a P-wave velocity profile with a relative precision of 1 to 2 m s-1. Simultaneously, the maximum peak-to-peak amplitudes of the transmission seismograms are evaluated to get a first idea on the amplitude attenuation along the sediment core. Two examples of gravity cores taken during a recent cruise of R.V. METEOR in the Western Equatorial Atlantic are presented. They yield that the P-wave profiles can be used for locating strong and fine-scale lithological changes, e.g. turbidite layers and slight variations in the sand, silt or clay content. In addition, the transmission seismograms and their amplitude spectra obviously seem to reveal a correlation between the relative amount of low-frequency spectral components and the sediment grain size, and thus provide a tool for the determination of additional, related physical or sedimentological parameters in future investigations.

  11. Automatic bio-sample bacteria detection system

    NASA Technical Reports Server (NTRS)

    Chappelle, E. W.; Colburn, M.; Kelbaugh, B. N.; Picciolo, G. L.

    1971-01-01

    Electromechanical device analyzes urine specimens in 15 minutes and processes one sample per minute. Instrument utilizes bioluminescent reaction between luciferase-luciferin mixture and adenosine triphosphate (ATP) to determine number of bacteria present in the sample. Device has potential application to analysis of other body fluids.

  12. Improvement and automation of a real-time PCR assay for vaginal fluids.

    PubMed

    De Vittori, E; Giampaoli, S; Barni, F; Baldi, M; Berti, A; Ripani, L; Romano Spica, V

    2016-05-01

    The identification of vaginal fluids is crucial in forensic science. Several molecular protocols based on PCR amplification of mfDNA (microflora DNA) specific for vaginal bacteria are now available. Unfortunately mfDNA extraction and PCR reactions require manual optimization of several steps. The aim of present study was the verification of a partial automatization of vaginal fluids identification through two instruments widely diffused in forensic laboratories: EZ1 Advanced robot and Rotor Gene Q 5Plex HRM. Moreover, taking advantage of 5-plex thermocycler technology, the ForFluid kit performances were improved by expanding the mfDNA characterization panel with a new bacterial target for vaginal fluids and with an internal positive control (IPC) to monitor PCR inhibition. Results underlined the feasibility of a semi-automated extraction of mfDNA using a BioRobot and demonstrated the analytical improvements of the kit. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. A MODIFIED LIGHT TRANSMISSION VISUALIZATION METHOD FOR DNAPL SATURATION MEASUREMENTS IN 2-D MODELS

    EPA Science Inventory

    In this research, a light transmission visualization (LTV) method was used to quantify dense non-aqueous phase liquids (DNAPL) saturation in two-dimensional (2-D), two fluid phase systems. The method is an expansion of earlier LTV methods and takes into account both absorption an...

  14. Automatic vision system for analysis of microscopic behavior of flow and transport in porous media

    NASA Astrophysics Data System (ADS)

    Rashidi, Mehdi; Dehmeshki, Jamshid; Dickenson, Eric; Daemi, M. Farhang

    1997-10-01

    This paper describes the development of a novel automated and efficient vision system to obtain velocity and concentration measurement within a porous medium. An aqueous fluid lace with a fluorescent dye to microspheres flows through a transparent, refractive-index-matched column packed with transparent crystals. For illumination purposes, a planar sheet of laser passes through the column as a CCD camera records all the laser illuminated planes. Detailed microscopic velocity and concentration fields have been computed within a 3D volume of the column. For measuring velocities, while the aqueous fluid, laced with fluorescent microspheres, flows through the transparent medium, a CCD camera records the motions of the fluorescing particles by a video cassette recorder. The recorded images are acquired automatically frame by frame and transferred to the computer for processing, by using a frame grabber an written relevant algorithms through an RS-232 interface. Since the grabbed image is poor in this stage, some preprocessings are used to enhance particles within images. Finally, these enhanced particles are monitored to calculate velocity vectors in the plane of the beam. For concentration measurements, while the aqueous fluid, laced with a fluorescent organic dye, flows through the transparent medium, a CCD camera sweeps back and forth across the column and records concentration slices on the planes illuminated by the laser beam traveling simultaneously with the camera. Subsequently, these recorded images are transferred to the computer for processing in similar fashion to the velocity measurement. In order to have a fully automatic vision system, several detailed image processing techniques are developed to match exact images that have different intensities values but the same topological characteristics. This results in normalized interstitial chemical concentrations as a function of time within the porous column.

  15. Crustal Fracturing Field and Presence of Fluid as Revealed by Seismic Anisotropy

    NASA Astrophysics Data System (ADS)

    Pastori, M.; Piccinini, D.; de Gori, P.; Margheriti, L.; Barchi, M. R.; di Bucci, D.

    2010-12-01

    In the last three years, we developed, tested and improved an automatic analysis code (Anisomat+) to calculate the shear wave splitting parameters, fast polarization direction (φ) and delay time (∂t). The code is a set of MatLab scripts able to retrieve crustal anisotropy parameters from three-component seismic recording of local earthquakes using horizontal component cross-correlation method. The analysis procedure consists in choosing an appropriate frequency range, that better highlights the signal containing the shear waves, and a length of time window on the seismogram centered on the S arrival (the temporal window contains at least one cycle of S wave). The code was compared to other two automatic analysis code (SPY and SHEBA) and tested on three Italian areas (Val d’Agri, Tiber Valley and L’Aquila surrounding) along the Apennine mountains. For each region we used the anisotropic parameters resulting from the automatic computation as a tool to determine the fracture field geometries connected with the active stress field. We compare the temporal variations of anisotropic parameters to the evolution of vp/vs ratio for the same seismicity. The anisotropic fast directions are used to define the active stress field (EDA model), finding a general consistence between fast direction and main stress indicators (focal mechanism and borehole break-out). The magnitude of delay time is used to define the fracture field intensity finding higher value in the volume where micro-seismicity occurs. Furthermore we studied temporal variations of anisotropic parameters and vp/vs ratio in order to explain if fluids play an important role in the earthquake generation process. The close association of anisotropic and vp/vs parameters variations and seismicity rate changes supports the hypothesis that the background seismicity is influenced by the fluctuation of pore fluid pressure in the rocks.

  16. 18 CFR 125.3 - Schedule of records and periods of retention.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... and agreements. 4. Accountants' and auditors' reports. Information Technology Management 5. Automatic... licensees (less nuclear). 13.2 Production—Nuclear. 14. Transmission and distribution—Public utilities and... Collection 29. Customers' service applications and contracts. 30. Rate schedules. 31. Maximum demand and...

  17. Tools for a Document Image Utility.

    ERIC Educational Resources Information Center

    Krishnamoorthy, M.; And Others

    1993-01-01

    Describes a project conducted at Rensselaer Polytechnic Institute (New York) that developed methods for automatically subdividing pages from technical journals into smaller semantic units for transmission, display, and further processing in an electronic environment. Topics discussed include optical scanning and image compression, digital image…

  18. 18 CFR 125.3 - Schedule of records and periods of retention.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... and agreements. 4. Accountants' and auditors' reports. Information Technology Management 5. Automatic.... Vouchers. Insurance 12. Insurance records. Operations and Maintenance 13.1. Production—Public utilities and licensees (less nuclear). 13.2 Production—Nuclear. 14. Transmission and distribution—Public utilities and...

  19. 47 CFR 97.207 - Space station.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....05 GHz segments. (d) A space station may automatically retransmit the radio signals of Earth stations... transmissions may consist of specially coded messages intended to facilitate communications or related to the... remaining source of stored energy, or through other equivalent procedures specifically disclosed in the...

  20. 47 CFR 97.207 - Space station.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....05 GHz segments. (d) A space station may automatically retransmit the radio signals of Earth stations... transmissions may consist of specially coded messages intended to facilitate communications or related to the... remaining source of stored energy, or through other equivalent procedures specifically disclosed in the...

  1. 47 CFR 97.207 - Space station.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....05 GHz segments. (d) A space station may automatically retransmit the radio signals of Earth stations... transmissions may consist of specially coded messages intended to facilitate communications or related to the... remaining source of stored energy, or through other equivalent procedures specifically disclosed in the...

  2. 47 CFR 97.207 - Space station.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....05 GHz segments. (d) A space station may automatically retransmit the radio signals of Earth stations... transmissions may consist of specially coded messages intended to facilitate communications or related to the... remaining source of stored energy, or through other equivalent procedures specifically disclosed in the...

  3. 47 CFR 97.207 - Space station.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....05 GHz segments. (d) A space station may automatically retransmit the radio signals of Earth stations... transmissions may consist of specially coded messages intended to facilitate communications or related to the... remaining source of stored energy, or through other equivalent procedures specifically disclosed in the...

  4. Elimination of gases and contamination from water

    NASA Technical Reports Server (NTRS)

    Buck, A. P.

    1970-01-01

    Filtration system with membrane type hydrophilic and hydrophobic filters gives absolute filtration with automatic venting of freed gases, and prevents backward transmission of contamination with no bacterial growth through the filters. Filter aids in degassing industrial solutions and in removing oxygen from sea water.

  5. Numerical modeling of the exterior-to-interior transmission of impulsive sound through three-dimensional, thin-walled elastic structures

    NASA Astrophysics Data System (ADS)

    Remillieux, Marcel C.; Pasareanu, Stephanie M.; Svensson, U. Peter

    2013-12-01

    Exterior propagation of impulsive sound and its transmission through three-dimensional, thin-walled elastic structures, into enclosed cavities, are investigated numerically in the framework of linear dynamics. A model was developed in the time domain by combining two numerical tools: (i) exterior sound propagation and induced structural loading are computed using the image-source method for the reflected field (specular reflections) combined with an extension of the Biot-Tolstoy-Medwin method for the diffracted field, (ii) the fully coupled vibro-acoustic response of the interior fluid-structure system is computed using a truncated modal-decomposition approach. In the model for exterior sound propagation, it is assumed that all surfaces are acoustically rigid. Since coupling between the structure and the exterior fluid is not enforced, the model is applicable to the case of a light exterior fluid and arbitrary interior fluid(s). The structural modes are computed with the finite-element method using shell elements. Acoustic modes are computed analytically assuming acoustically rigid boundaries and rectangular geometries of the enclosed cavities. This model is verified against finite-element solutions for the cases of rectangular structures containing one and two cavities, respectively.

  6. The relationship between parents' and children's automatic thoughts in a college student sample.

    PubMed

    Donnelly, Reesa; Renk, Kimberly; Sims, Valerie K; McGuire, Jack

    2011-04-01

    Research demonstrates the importance of early social interactions in the development of schemas and automatic thoughts. It does not appear, however, that the existing research examines intergenerational correlations in automatic thoughts. As a result, this study explores the relationship between the automatic thoughts of parents and those of their college-age children in a sample of 252 college students and their mothers and fathers. Results of this study suggest that there are significant relationships between parents' and college students' positive automatic thoughts. Different trends by gender also are noted in the relationships among variables for male and female college students with their mothers and fathers. Further, mothers' positive ATs predicted the positive ATs of their college students, with mothers' ratings of their own communication with their college students mediating partially this relationship. Finally, college students' anxiety and self-esteem is predicted significantly by their mothers' anxiety and self-esteem (respectively) as well as their own positive and negative ATs. These findings suggest the possibility that ATs play a role in the intergenerational transmission of certain domains of psychological functioning.

  7. TEM Study of Intergranular Fluid Distributions in Rocks at a Nanometer Scale

    NASA Astrophysics Data System (ADS)

    Hiraga, T.; Anderson, I. M.; Kohlstedt, D. L.

    2002-12-01

    The distribution of intergranular fluids in rocks plays an essential role in fluid migration and rock rheology. Structural and chemical analyses with sub-nanometer resolution is possible with transmission and scanning-transmission electron microscopy; therefore, it is possible to perform the fine-scale structural analyses required to determine the presence or absence of very thin fluid films along grain boundaries. For aqueous fluids in crustal rocks, Hiraga et al. (2001) observed a fluid morphology controlled by the relative values of the solid-solid and solid-fluid interfacial energies, which resulted in well-defined dihedral angles. Their high-resolution transmission electron microscopy (TEM) observations demonstrate that grain boundaries are tight even at a nanometer scale, consistent with the absence of aqueous fluid films. For partially molten ultra-mafic rocks, two conflicting conclusions have been reached: nanometer-thick melt films wet grain boundaries (Drury and Fitz Gerald 1996; De Kloe et al. 2000) versus essentially all grain boundaries are melt-free (Vaughan et al. 1982; Kohlstedt 1990). To resolve this conflict, Hiraga et al. (2002) examined grain boundaries in quenched partially molten peridotites. Their observations demonstrate the following: (i) Although a small fraction of the grains are separated by relatively thick (~1 μm) layers of melt, lattice fringe images obtained with a high-resolution TEM reveal that most of the remaining boundaries do not contain a thin amorphous phase. (ii) In addition, the composition of olivine-olivine grain boundaries was analyzed with a nano-beam analytical scanning TEM with a probe size of <2 nm. Although the grain boundaries contained no melt film, the concentration of Ca, Al and Ti were enhanced near the boundaries. The segregation of these elements to the grain boundaries formed enriched regions <7 nm wide. A similar pattern of chemical segregation was detected in subsolidus systems. Creep experiments on the partially molten rocks that were analyzed in this study reveal little weakening even at melt contents approaching 4 vol%, consistent with our observations of melt-free grain boundaries.

  8. The global transmission network of HIV-1.

    PubMed

    Wertheim, Joel O; Leigh Brown, Andrew J; Hepler, N Lance; Mehta, Sanjay R; Richman, Douglas D; Smith, Davey M; Kosakovsky Pond, Sergei L

    2014-01-15

    Human immunodeficiency virus type 1 (HIV-1) is pandemic, but its contemporary global transmission network has not been characterized. A better understanding of the properties and dynamics of this network is essential for surveillance, prevention, and eventual eradication of HIV. Here, we apply a simple and computationally efficient network-based approach to all publicly available HIV polymerase sequences in the global database, revealing a contemporary picture of the spread of HIV-1 within and between countries. This approach automatically recovered well-characterized transmission clusters and extended other clusters thought to be contained within a single country across international borders. In addition, previously undescribed transmission clusters were discovered. Together, these clusters represent all known modes of HIV transmission. The extent of international linkage revealed by our comprehensive approach demonstrates the need to consider the global diversity of HIV, even when describing local epidemics. Finally, the speed of this method allows for near-real-time surveillance of the pandemic's progression.

  9. Infectious Prions in the Pregnancy Microenvironment of Chronic Wasting Disease-Infected Reeves' Muntjac Deer

    PubMed Central

    Nalls, Amy V.; McNulty, Erin; Hoover, Clare E.; Pulscher, Laura A.; Hoover, Edward A.

    2017-01-01

    ABSTRACT Ample evidence exists for the presence of infectious agents at the maternal-fetal interface, often with grave outcomes to the developing fetus (i.e., Zika virus, brucella, cytomegalovirus, and toxoplasma). While less studied, pregnancy-related transmissible spongiform encephalopathies (TSEs) have been implicated in several species, including humans. Our previous work has shown that prions can be transferred from mother to offspring, resulting in the development of clinical TSE disease in offspring born to muntjac dams infected with chronic wasting disease (CWD) (1). We further demonstrated protein misfolding cyclic amplification (PMCA)-competent prions within the female reproductive tract and in fetal tissues harvested from CWD experimentally and naturally exposed cervids (1, 2). To assess whether the PMCA-competent prions residing at the maternal-fetal interface were infectious and to determine if the real-time quaking-induced conversion (RT-QuIC) methodology may enhance our ability to detect amyloid fibrils within the pregnancy microenvironment, we employed a mouse bioassay and RT-QuIC. In this study, we have demonstrated RT-QuIC seeding activity in uterus, placentome, ovary, and amniotic fluid but not in allantoic fluids harvested from CWD-infected Reeves' muntjac dams showing clinical signs of infection (clinically CWD-infected) and in some placentomes from pre-clinically CWD-infected dams. Prion infectivity was confirmed within the uterus, amniotic fluid, and the placentome, the semipermeable interface that sustains the developing fetus, of CWD-infected dams. This is the first report of prion infectivity within the cervid pregnancy microenvironment, revealing a source of fetal CWD exposure prior to the birthing process, maternal grooming, or encounters with contaminated environments. IMPORTANCE The facile dissemination of chronic wasting disease within captive and free-range cervid populations has led to questions regarding the transmission dynamics of this disease. Direct contact with infected animals and indirect contact with infectious prions in bodily fluids and contaminated environments are suspected to explain the majority of this transmission. A third mode of transmission, from mother to offspring, may be underappreciated. The presence of pregnancy-related prion infectivity within the uterus, amniotic fluid, and the placental structure reveals that the developing fetus is exposed to a source of prions long before exposure to the infectious agent during and after the birthing process or via contact with contaminated environments. These findings have impact on our current concept of CWD disease transmission. PMID:28539446

  10. Automatically calibrating admittances in KATE's autonomous launch operations model

    NASA Technical Reports Server (NTRS)

    Morgan, Steve

    1992-01-01

    This report documents a 1000-line Symbolics LISP program that automatically calibrates all 15 fluid admittances in KATE's Autonomous Launch Operations (ALO) model. (KATE is Kennedy Space Center's Knowledge-based Autonomous Test Engineer, a diagnosis and repair expert system created for use on the Space Shuttle's various fluid flow systems.) As a new KATE application, the calibrator described here breaks new ground for KSC's Artificial Intelligence Lab by allowing KATE to both control and measure the hardware she supervises. By automating a formerly manual process, the calibrator: (1) saves the ALO model builder untold amounts of labor; (2) enables quick repairs after workmen accidently adjust ALO's hand valves; and (3) frees the modeler to pursue new KATE applications that previously were too complicated. Also reported are suggestions for enhancing the program: (1) to calibrate ALO's TV cameras, pumps, and sensor tolerances; and (2) to calibrate devices in other KATE models, such as the shuttle's LOX and Environment Control System (ECS).

  11. Performance Evaluation of Strain Gauge Printed Using Automatic Fluid Dispensing System on Conformal Substrates

    NASA Astrophysics Data System (ADS)

    Khairilhijra Khirotdin, Rd.; Faridzuan Ngadiron, Mohamad; Adzeem Mahadzir, Muhammad; Hassan, Nurhafizzah

    2017-08-01

    Smart textiles require flexible electronics that can withstand daily stresses like bends and stretches. Printing using conductive inks provides the flexibility required but the current printing techniques suffered from ink incompatibility, limited of substrates to be printed with and incompatible with conformal substrates due to its rigidity and low flexibility. An alternate printing technique via automatic fluid dispensing system is proposed and its performances on printing strain gauge on conformal substrates were evaluated to determine its feasibility. Process parameters studied including printing speed, deposition height, curing time and curing temperature. It was found that the strain gauge is proven functional as expected since different strains were induced when bent on variation of bending angles and curvature radiuses from designated bending fixtures. The average change of resistances were doubled before the strain gauge starts to break. Printed strain gauges also exhibited some excellence elasticity as they were able to resist bending up to 70° angle and 3 mm of curvature radius.

  12. Development of a high-resolution automatic digital (urine/electrolytes) flow volume and rate measurement system of miniature size

    NASA Technical Reports Server (NTRS)

    Liu, F. F.

    1975-01-01

    To aid in the quantitative analysis of man's physiological rhythms, a flowmeter to measure circadian patterns of electrolyte excretion during various environmental stresses was developed. One initial flowmeter was designed and fabricated, the sensor of which is the approximate size of a wristwatch. The detector section includes a special type of dielectric integrating type sensor which automatically controls, activates, and deactivates the flow sensor data output by determining the presence or absence of fluid flow in the system, including operation under zero-G conditions. The detector also provides qualitative data on the composition of the fluid. A compact electronic system was developed to indicate flow rate as well as total volume per release or the cumulative volume of several releases in digital/analog forms suitable for readout or telemetry. A suitable data readout instrument is also provided. Calibration and statistical analyses of the performance functions required of the flowmeter were also conducted.

  13. Improved passive optical network architectures to support local area network emulation and protection

    NASA Astrophysics Data System (ADS)

    Wong, Elaine; Nadarajah, Nishaanthan; Chae, Chang-Joon; Nirmalathas, Ampalavanapillai; Attygalle, Sanjeewa M.

    2006-01-01

    We describe two optical layer schemes which simultaneously facilitate local area network emulation and automatic protection switching against distribution fiber breaks in passive optical networks. One scheme employs a narrowband fiber Bragg grating placed close to the star coupler in the feeder fiber of the passive optical network, while the other uses an additional short length distribution fiber from the star coupler to each customer for the redirection of the customer traffic. Both schemes use RF subcarrier multiplexed transmission for intercommunication between customers in conjunction with upstream access to the central office at baseband. Failure detection and automatic protection switching are performed independently by each optical network unit that is located at the customer premises in a distributed manner. The restoration of traffic transported between the central office and an optical network unit in the event of the distribution fiber break is performed by interconnecting adjacent optical network units and carrying out signal transmissions via an independent but interconnected optical network unit. Such a protection mechanism enables multiple adjacent optical network units to be simultaneously protected by a single optical network unit utilizing its maximum available bandwidth. We experimentally verify the feasibility of both schemes with 1.25 Gb/s upstream baseband transmission to the central office and 155 Mb/s local area network data transmission on a RF subcarrier frequency. The experimental results obtained from both schemes are compared, and the power budgets are calculated to analyze the scalability of each scheme.

  14. Toward Non-Invasive and Automatic Intravenous Infiltration Detection: Evaluation of Bioimpedance and Skin Strain in a Pig Model.

    PubMed

    Bicen, A Ozan; West, Leanne L; Cesar, Liliana; Inan, Omer T

    2018-01-01

    Intravenous (IV) therapy is prevalent in hospital settings, where fluids are typically delivered with an IV into a peripheral vein of the patient. IV infiltration is the inadvertent delivery of fluids into the extravascular space rather than into the vein (and requires urgent treatment to avoid scarring and severe tissue damage), for which medical staff currently needs to check patients periodically. In this paper, the performance of two non-invasive sensing modalities, electrical bioimpedance (EBI), and skin strain sensing, for the automatic detection of IV infiltration was investigated in an animal model. Infiltrations were physically simulated on the hind limb of anesthetized pigs, where the sensors for EBI and skin strain sensing were co-located. The obtained data were used to examine the ability to distinguish between infusion into the vein and an infiltration event using bioresistance and bioreactance (derived from EBI), as well as skin strain. Skin strain and bioresistance sensing could achieve detection rates greater than 0.9 for infiltration fluid volumes of 2 and 10 mL, respectively, for a given false positive, i.e., false alarm rate of 0.05. Furthermore, the fusion of multiple sensing modalities could achieve a detection rate of 0.97 with a false alarm rate of 0.096 for 5mL fluid volume of infiltration. EBI and skin strain sensing can enable non-invasive and real-time IV infiltration detection systems. Fusion of multiple sensing modalities can help to detect expanded range of leaking fluid volumes. The provided performance results and comparisons in this paper are an important step towards clinical translation of sensing technologies for detecting IV infiltration.

  15. Toward Non-Invasive and Automatic Intravenous Infiltration Detection: Evaluation of Bioimpedance and Skin Strain in a Pig Model

    PubMed Central

    Bicen, A. Ozan; West, Leanne L.; Cesar, Liliana

    2018-01-01

    Intravenous (IV) therapy is prevalent in hospital settings, where fluids are typically delivered with an IV into a peripheral vein of the patient. IV infiltration is the inadvertent delivery of fluids into the extravascular space rather than into the vein (and requires urgent treatment to avoid scarring and severe tissue damage), for which medical staff currently needs to check patients periodically. In this paper, the performance of two non-invasive sensing modalities, electrical bioimpedance (EBI), and skin strain sensing, for the automatic detection of IV infiltration was investigated in an animal model. Infiltrations were physically simulated on the hind limb of anesthetized pigs, where the sensors for EBI and skin strain sensing were co-located. The obtained data were used to examine the ability to distinguish between infusion into the vein and an infiltration event using bioresistance and bioreactance (derived from EBI), as well as skin strain. Skin strain and bioresistance sensing could achieve detection rates greater than 0.9 for infiltration fluid volumes of 2 and 10 mL, respectively, for a given false positive, i.e., false alarm rate of 0.05. Furthermore, the fusion of multiple sensing modalities could achieve a detection rate of 0.97 with a false alarm rate of 0.096 for 5mL fluid volume of infiltration. EBI and skin strain sensing can enable non-invasive and real-time IV infiltration detection systems. Fusion of multiple sensing modalities can help to detect expanded range of leaking fluid volumes. The provided performance results and comparisons in this paper are an important step towards clinical translation of sensing technologies for detecting IV infiltration. PMID:29692956

  16. 38 CFR 17.157 - Definition-adaptive equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... includes, but is not limited to, a basic automatic transmission, power steering, power brakes, power window lifts, power seats, air-conditioning equipment when necessary for the health and safety of the veteran... MEDICAL Automotive Equipment and Driver Training § 17.157 Definition-adaptive equipment. The term...

  17. 47 CFR 1.907 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... requests to assign rights granted by the authorization or to transfer control of entities holding... in the station's authorization or rules. Control station. A fixed station, the transmissions of which are used to control automatically the emissions or operations of a radio station, or a remote base...

  18. 47 CFR 1.907 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... term also encompasses requests to assign rights granted by the authorization or to transfer control of.... This power is specified by the Commission in the station's authorization or rules. Control station. A fixed station, the transmissions of which are used to control automatically the emissions or operations...

  19. 47 CFR 87.149 - Special requirements for automatic link establishment (ALE).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... exceed 100 W ERP; (b) Transmissions must sweep linearly in frequency at a rate of at least 60 kHz per... frequencies and frequency bands must not exceed 10 µW peak ERP: (1) Protected frequencies (kHz) 2091.0 4188.0...

  20. 7 CFR 1710.251 - Construction work plans-distribution borrowers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... generation facilities; (11) Load management equipment, automatic sectionalizing facilities, and centralized... transmission plant, and improvements replacements, and retirements of any generation plant. Construction of new generation capacity need not be included in a CWP but must be specified and supported by specific engineering...

  1. Self-Organizing Fluid Convection Patterns in an en Echelon Fault Array

    NASA Astrophysics Data System (ADS)

    Patterson, James W.; Driesner, Thomas; Matthai, Stephan K.

    2018-05-01

    We present three-dimensional numerical simulations of natural convection in buried, vertical en echelon faults in impermeable host rock. Despite the fractures being hydraulically disconnected, convection within each fracture alters the temperature field in the surrounding host rock, altering convection in neighboring fractures. This leads to self-organization of coherent patterns of upward/downward flow and heating/cooling of the host rock spanning the entire fault array. This "synchronization" effect occurs when fracture spacing is less than the width of convection cells within the fractures, which is controlled by fracture transmissivity (permeability times thickness) and heterogeneity. Narrow fracture spacing and synchronization enhance convective fluid flow within fractures and cause convection to initiate earlier, even lowering the critical transmissivity necessary for convection initiation. Heat flow through the en echelon region, however, is enhanced only in low-transmissivity fractures, while heat flow in high-permeability fractures is reduced due to thermal interference between fractures.

  2. Analysis of automatic repeat request methods for deep-space downlinks

    NASA Technical Reports Server (NTRS)

    Pollara, F.; Ekroot, L.

    1995-01-01

    Automatic repeat request (ARQ) methods cannot increase the capacity of a memoryless channel. However, they can be used to decrease the complexity of the channel-coding system to achieve essentially error-free transmission and to reduce link margins when the channel characteristics are poorly predictable. This article considers ARQ methods on a power-limited channel (e.g., the deep-space channel), where it is important to minimize the total power needed to transmit the data, as opposed to a bandwidth-limited channel (e.g., terrestrial data links), where the spectral efficiency or the total required transmission time is the most relevant performance measure. In the analysis, we compare the performance of three reference concatenated coded systems used in actual deep-space missions to that obtainable by ARQ methods using the same codes, in terms of required power, time to transmit with a given number of retransmissions, and achievable probability of word error. The ultimate limits of ARQ with an arbitrary number of retransmissions are also derived.

  3. Precise nanoliter fluid handling system with integrated high-speed flow sensor.

    PubMed

    Haber, Carsten; Boillat, Marc; van der Schoot, Bart

    2005-04-01

    A system for accurate low-volume delivery of liquids in the micro- to nanoliter range makes use of an integrated miniature flow sensor as part of an intelligent feedback control loop driving a micro-solenoid valve. The flow sensor is hydraulically connected with the pressurized system liquid in the dispensing channel and located downstream from the pressure source, above the solenoid valve. The sensor operates in a differential mode and responds in real-time to the internal flow-pulse resulting from the brief opening interval of the solenoid valve leading to a rapid ejection of a fluid droplet. The integral of the flow-pulse delivered by the sensor is directly proportional to the volume of the ejected droplet from the nozzle. The quantitative information is utilized to provide active control of the effectively dispensed or aspirated volume by adjusting the solenoid valve accordingly. This process significantly enhances the precision of the fluid delivery. The system furthermore compensates automatically for any changes in the viscosity of the dispensed liquid. The data delivered by the flow sensor can be saved and backtracked in order to confirm and validate the aspiration and dispensing process in its entirety. The collected dispense information can be used for quality control assessments and automatically be made part of an electronic record.

  4. Bottlenecks in HIV-1 transmission: insights from the study of founder viruses

    PubMed Central

    Joseph, Sarah B.; Swanstrom, Ronald; Kashuba, Angela D. M.; Cohen, Myron S.

    2016-01-01

    HIV-1 infection typically results from the transmission of a single viral variant, the transmitted/founder (T/F) virus. Studies of these HIV-1 variants provide critical information about the transmission bottlenecks and the selective pressures acting on the virus in the transmission fluid and in the recipient tissues. These studies reveal that T/F virus phenotypes are shaped by stochastic and selective forces that restrict transmission and may be targets for prevention strategies. In this Review, we highlight how studies of T/F viruses contribute to a better understanding of the biology of HIV-1 transmission and discuss how these findings affect HIV-1 prevention strategies. PMID:26052661

  5. Posteriori error determination and grid adaptation for AMR and ALE computational fluid dynamics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lapenta, G. M.

    2002-01-01

    We discuss grid adaptation for application to AMR and ALE codes. Two new contributions are presented. First, a new method to locate the regions where the truncation error is being created due to an insufficient accuracy: the operator recovery error origin (OREO) detector. The OREO detector is automatic, reliable, easy to implement and extremely inexpensive. Second, a new grid motion technique is presented for application to ALE codes. The method is based on the Brackbill-Saltzman approach but it is directly linked to the OREO detector and moves the grid automatically to minimize the error.

  6. FRACTIONATING COLUMN PRODUCT COLLECTOR CONTROL

    DOEpatents

    Paxson, G.D. Jr.

    1964-03-10

    Means for detecting minute fluid products from a chemical separation column and for advancing a collector tube rack in order to automatically separate and collect successive fractionated products are described. A charge is imposed on the forming drops at the column orifice to create an electric field as the drop falls in the vicinity of a sensing plate. The field is detected by an electrometer tube coupled to the plate causing an output signal to actuate rotation of a collector turntable rack, thereby positioning new collectors under the orifice. The invention provides reliable automatic collection independent of drop size, rate of fall, or chemical composition. (AEC)

  7. Determination of absorption coefficient of nanofluids with unknown refractive index from reflection and transmission spectra

    NASA Astrophysics Data System (ADS)

    Kim, Joong Bae; Lee, Seungyoon; Lee, Kyungeun; Lee, Ikjin; Lee, Bong Jae

    2018-07-01

    It has been shown that the absorption coefficient of a nanofluid can be actively tuned by changing material, size, shape, and concentration of the nanoparticle suspension. In applications of engineered nanofluids for the direct absorption of solar radiation, it is important to experimentally characterize the absorption coefficient of nanofluids in the solar spectrum. If the refractive index of the base fluid (i.e., the solution without nanoparticles) is known a priori, the absorption coefficient of nanofluids can be easily determined from the transmission spectrum. However, if the refractive index of the base fluid is not known, it is not straightforward to extract the absorption coefficient solely from the transmission spectrum. The present work aims to develop an analytical method of determining the absorption coefficient of nanofluids with unknown refractive index by measuring both reflection and transmission spectra. The proposed method will be validated with deionized water, and the effect of measurement uncertainty will be carefully examined. Finally, the general applicability of the proposed method will also be demonstrated for Therminol VP-1 as well as the Therminol VP-1 - graphite nanofluid.

  8. Automatic, semi-automatic and manual validation of urban drainage data.

    PubMed

    Branisavljević, N; Prodanović, D; Pavlović, D

    2010-01-01

    Advances in sensor technology and the possibility of automated long distance data transmission have made continuous measurements the preferable way of monitoring urban drainage processes. Usually, the collected data have to be processed by an expert in order to detect and mark the wrong data, remove them and replace them with interpolated data. In general, the first step in detecting the wrong, anomaly data is called the data quality assessment or data validation. Data validation consists of three parts: data preparation, validation scores generation and scores interpretation. This paper will present the overall framework for the data quality improvement system, suitable for automatic, semi-automatic or manual operation. The first two steps of the validation process are explained in more detail, using several validation methods on the same set of real-case data from the Belgrade sewer system. The final part of the validation process, which is the scores interpretation, needs to be further investigated on the developed system.

  9. 49 CFR 195.450 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... remote control valve as follows: (1) Check valve means a valve that permits fluid to flow freely in one direction and contains a mechanism to automatically prevent flow in the other direction. (2) Remote control.... The RCV is usually operated by the supervisory control and data acquisition (SCADA) system. The...

  10. 49 CFR 195.450 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... remote control valve as follows: (1) Check valve means a valve that permits fluid to flow freely in one direction and contains a mechanism to automatically prevent flow in the other direction. (2) Remote control.... The RCV is usually operated by the supervisory control and data acquisition (SCADA) system. The...

  11. 49 CFR 195.450 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... remote control valve as follows: (1) Check valve means a valve that permits fluid to flow freely in one direction and contains a mechanism to automatically prevent flow in the other direction. (2) Remote control.... The RCV is usually operated by the supervisory control and data acquisition (SCADA) system. The...

  12. 49 CFR 195.450 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... remote control valve as follows: (1) Check valve means a valve that permits fluid to flow freely in one direction and contains a mechanism to automatically prevent flow in the other direction. (2) Remote control.... The RCV is usually operated by the supervisory control and data acquisition (SCADA) system. The...

  13. 49 CFR 195.450 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... remote control valve as follows: (1) Check valve means a valve that permits fluid to flow freely in one direction and contains a mechanism to automatically prevent flow in the other direction. (2) Remote control.... The RCV is usually operated by the supervisory control and data acquisition (SCADA) system. The...

  14. Transducer for downhole drilling components

    DOEpatents

    Hall, David R; Fox, Joe R

    2006-05-30

    A robust transmission element for transmitting information between downhole tools, such as sections of drill pipe, in the presence of hostile environmental conditions, such as heat, dirt, rocks, mud, fluids, lubricants, and the like. The transmission element maintains reliable connectivity between transmission elements, thereby providing an uninterrupted flow of information between drill string components. A transmission element is mounted within a recess proximate a mating surface of a downhole drilling component, such as a section of drill pipe. The transmission element may include an annular housing forming a trough, an electrical conductor disposed within the trough, and an MCEI material disposed between the annular housing and the electrical conductor.

  15. Automatic transponder. [measurement of the internal delay time of a transponder

    NASA Technical Reports Server (NTRS)

    Anderson, R. E.; Brisken, A. F.; Lewis, J. R. (Inventor)

    1977-01-01

    A method and apparatus for the automatic, remote measurement of the internal delay time of a transponder at the time of operation is provided. A small portion of the transmitted signal of the transponder is converted to the receive signal frequency of the transponder and supplied to the input of the transponder. The elapsed time between the receive signal locally generated and the receive signal causing the transmission of the transmitted signal is measured, said time being representative of or equal to the internal delay time of the transponder at the time of operation.

  16. Numerical Calculation and Experiment of Coupled Dynamics of the Differential Velocity Vane Pump Driven by the Hybrid Higher-order Fourier Non-circular Gears

    NASA Astrophysics Data System (ADS)

    Xu, Gaohuan; Chen, Jianneng; Zhao, Huacheng

    2018-06-01

    The transmission systems of the differential velocity vane pumps (DVVP) have periodic vibrations under loads. And it is not easy to find the reason. In order to optimize the performance of the pump, the authors proposed DVVP driven by the hybrid Higher-order Fourier non-circular gears and tested it. There were also similar periodic vibrations and noises under loads. Taking into account this phenomenon, the paper proposes fluid mechanics and solid mechanics simulation methodology to analyze the coupling dynamics between fluid and transmission system and reveals the reason. The results show that the pump has the reverse drive phenomenon, which is that the blades drive the non-circular gears when the suction and discharge is alternating. The reverse drive phenomenon leads the sign of the shaft torque to be changed in positive and negative way. So the transmission system produces torsional vibrations. In order to confirm the simulation results, micro strains of the input shaft of the pump impeller are measured by the Wheatstone bridge and wireless sensor technology. The relationships between strain and torque are obtained by experimental calibration, and then the true torque of input shaft is calculated indirectly. The experimental results are consistent to the simulation results. It is proven that the periodic vibrations are mainly caused by fluid solid coupling, which leads to periodic torsional vibration of the transmission system.

  17. Tensor Arithmetic, Geometric and Mathematic Principles of Fluid Mechanics in Implementation of Direct Computational Experiments

    NASA Astrophysics Data System (ADS)

    Bogdanov, Alexander; Khramushin, Vasily

    2016-02-01

    The architecture of a digital computing system determines the technical foundation of a unified mathematical language for exact arithmetic-logical description of phenomena and laws of continuum mechanics for applications in fluid mechanics and theoretical physics. The deep parallelization of the computing processes results in functional programming at a new technological level, providing traceability of the computing processes with automatic application of multiscale hybrid circuits and adaptive mathematical models for the true reproduction of the fundamental laws of physics and continuum mechanics.

  18. Supercritical Fluid Infusion of Iron Additives in Polymeric Matrices

    NASA Technical Reports Server (NTRS)

    Nazem, Negin; Taylor, Larry T.

    1999-01-01

    The objective of this project was the experimentation to measure preparation of iron nanophases within polymeric matrices via supercritical fluid infusion of iron precursors followed by thermal reduction. Another objective was to determine if supercritical CO2 could infuse into the polymer. The experiment is described along with the materials, and the supercritical fluid infusion and cure procedures. X-ray photoelectron spectra and transmission electron micrographs were obtained. The results are summarized in charts, and tables.

  19. Automatic measurement of contact angle in pore-space images

    NASA Astrophysics Data System (ADS)

    AlRatrout, Ahmed; Raeini, Ali Q.; Bijeljic, Branko; Blunt, Martin J.

    2017-11-01

    A new approach is presented to measure the in-situ contact angle (θ) between immiscible fluids, applied to segmented pore-scale X-ray images. We first identify and mesh the fluid/fluid and fluid/solid interfaces. A Gaussian smoothing is applied to this mesh to eliminate artifacts associated with the voxelized nature of the image, while preserving large-scale features of the rock surface. Then, for the fluid/fluid interface we apply an additional smoothing and adjustment of the mesh to impose a constant curvature. We then track the three-phase contact line, and the two vectors that have a direction perpendicular to both surfaces: the contact angle is found from the dot product of these vectors where they meet at the contact line. This calculation can be applied at every point on the mesh at the contact line. We automatically generate contact angle values representing each invaded pore-element in the image with high accuracy. To validate the approach, we first study synthetic three-dimensional images of a spherical droplet of oil residing on a tilted flat solid surface surrounded by brine and show that our results are accurate to within 3° if the sphere diameter is 2 or more voxels. We then apply this method to oil/brine systems imaged at ambient temperature and reservoir pressure (10MPa) using X-ray microtomography (Singh et al., 2016). We analyse an image volume of diameter approximately 4.6 mm and 10.7 mm long, obtaining hundreds of thousands of values from a dataset with around 700 million voxels. We show that in a system of altered wettability, contact angles both less than and greater than 90° can be observed. This work provides a rapid method to provide an accurate characterization of pore-scale wettability, which is important for the design and assessment of hydrocarbon recovery and carbon dioxide storage.

  20. World Key Information Service System Designed For EPCOT Center

    NASA Astrophysics Data System (ADS)

    Kelsey, J. A.

    1984-03-01

    An advanced Bell Laboratories and Western Electric designed electronic information retrieval system utilizing the latest Information Age technologies, and a fiber optic transmission system is featured at the Walt Disney World Resort's newest theme park - The Experimental Prototype Community of Tomorrow (EPCOT Center). The project is an interactive audio, video and text information system that is deployed at key locations within the park. The touch sensitive terminals utilizing the ARIEL (Automatic Retrieval of Information Electronically) System is interconnected by a Western Electric designed and manufactured lightwave transmission system.

  1. Gas turbine engines and transmissions for bus demonstration programs. Technical status report, 31 October 1979-31 January 1980

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nigro, D.N.

    1980-02-01

    Progress is reported on the procurement and delivery of 11 Allison GT 404-4 Industrial Gas Turbine Engines and 5 HT740CT and 6 V730CT Allison Automatic Transmissions for the Greyhound and Transit Coaches, respectively. Ceramic regenerators have been incorporated in the build configuration for last 4 Transit Coach engines. The 5 Greyhound Coach engines and the first 2 Transit Coach engines were built in the all-metal configuration. The Master Schedules for the program are presented.

  2. National Program for Inspection of Non-Federal Dams. Prym Manufacturing Co. Dam (CT 00169), Thames River Basin, Killingly, Connecticut. Phase I Inspection Report.

    DTIC Science & Technology

    1979-06-01

    Service (DDS), which offers speeds of 19.2K bps and 56K bps. Instead of modems , DDS service requires a Channel Service Unit (CSU), to terminate each...Bell 103 modem that automatically calls for help if the DDS link goes down. DDS users can also use their own schemes to protect their transmissions...Switched 56 service provides 700 numbers for 56K transmission in some 60 odd cities, including areas such as Orlando, San Diego, and the Washington

  3. Data transmission system with distributed microprocessors

    DOEpatents

    Nambu, Shigeo

    1985-01-01

    A data transmission system having a common request line and a special request line in addition to a transmission line. The special request line has priority over the common request line. A plurality of node stations are multi-drop connected to the transmission line. Among the node stations, a supervising station is connected to the special request line and takes precedence over other slave stations to become a master station. The master station collects data from the slave stations. The station connected to the common request line can assign a master control function to any station requesting to be assigned the master control function within a short period of time. Each station has an auto response control circuit. The master station automatically collects data by the auto response controlling circuit independently of the microprocessors of the slave stations.

  4. Automatic, accurate, and reproducible segmentation of the brain and cerebro-spinal fluid in T1-weighted volume MRI scans and its application to serial cerebral and intracranial volumetry

    NASA Astrophysics Data System (ADS)

    Lemieux, Louis

    2001-07-01

    A new fully automatic algorithm for the segmentation of the brain and cerebro-spinal fluid (CSF) from T1-weighted volume MRI scans of the head was specifically developed in the context of serial intra-cranial volumetry. The method is an extension of a previously published brain extraction algorithm. The brain mask is used as a basis for CSF segmentation based on morphological operations, automatic histogram analysis and thresholding. Brain segmentation is then obtained by iterative tracking of the brain-CSF interface. Grey matter (GM), white matter (WM) and CSF volumes are calculated based on a model of intensity probability distribution that includes partial volume effects. Accuracy was assessed using a digital phantom scan. Reproducibility was assessed by segmenting pairs of scans from 20 normal subjects scanned 8 months apart and 11 patients with epilepsy scanned 3.5 years apart. Segmentation accuracy as measured by overlap was 98% for the brain and 96% for the intra-cranial tissues. The volume errors were: total brain (TBV): -1.0%, intra-cranial (ICV):0.1%, CSF: +4.8%. For repeated scans, matching resulted in improved reproducibility. In the controls, the coefficient of reliability (CR) was 1.5% for the TVB and 1.0% for the ICV. In the patients, the Cr for the ICV was 1.2%.

  5. Fiber optic fluid detector

    DOEpatents

    Angel, S. Michael

    1989-01-01

    Particular gases or liquids are detected with a fiber optic element (11, 11a to 11j) having a cladding or coating of a material (23, 23a to 23j) which absorbs the fluid or fluids and which exhibits a change of an optical property, such as index of refraction, light transmissiveness or fluoresence emission, for example, in response to absorption of the fluid. The fluid is sensed by directing light into the fiber optic element and detecting changes in the light, such as exit angle changes for example, that result from the changed optical property of the coating material. The fluid detector (24, 24a to 24j) may be used for such purposes as sensing toxic or explosive gases in the atmosphere, measuring ground water contamination or monitoring fluid flows in industrial processes, among other uses.

  6. 46 CFR 58.25-85 - Special requirements for tank vessels.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...” in paragraph (g) of this section refers to the pressure-containing components in hydraulic or electro... least two identical hydraulic-power actuating systems, which, acting simultaneously in normal operation... hydraulic fluid from one system must be capable of being detected, and the defective system automatically...

  7. 46 CFR 58.25-85 - Special requirements for tank vessels.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...” in paragraph (g) of this section refers to the pressure-containing components in hydraulic or electro... least two identical hydraulic-power actuating systems, which, acting simultaneously in normal operation... hydraulic fluid from one system must be capable of being detected, and the defective system automatically...

  8. Functional-to-form mapping for assembly design automation

    NASA Astrophysics Data System (ADS)

    Xu, Z. G.; Liu, W. M.; Shen, W. D.; Yang, D. Y.; Liu, T. T.

    2017-11-01

    Assembly-level function-to-form mapping is the most effective procedure towards design automation. The research work mainly includes: the assembly-level function definitions, product network model and the two-step mapping mechanisms. The function-to-form mapping is divided into two steps, i.e. mapping of function-to-behavior, called the first-step mapping, and the second-step mapping, i.e. mapping of behavior-to-structure. After the first step mapping, the three dimensional transmission chain (or 3D sketch) is studied, and the feasible design computing tools are developed. The mapping procedure is relatively easy to be implemented interactively, but, it is quite difficult to finish it automatically. So manual, semi-automatic, automatic and interactive modification of the mapping model are studied. A mechanical hand F-F mapping process is illustrated to verify the design methodologies.

  9. Automatic view synthesis by image-domain-warping.

    PubMed

    Stefanoski, Nikolce; Wang, Oliver; Lang, Manuel; Greisen, Pierre; Heinzle, Simon; Smolic, Aljosa

    2013-09-01

    Today, stereoscopic 3D (S3D) cinema is already mainstream, and almost all new display devices for the home support S3D content. S3D distribution infrastructure to the home is already established partly in the form of 3D Blu-ray discs, video on demand services, or television channels. The necessity to wear glasses is, however, often considered as an obstacle, which hinders broader acceptance of this technology in the home. Multiviewautostereoscopic displays enable a glasses free perception of S3D content for several observers simultaneously, and support head motion parallax in a limited range. To support multiviewautostereoscopic displays in an already established S3D distribution infrastructure, a synthesis of new views from S3D video is needed. In this paper, a view synthesis method based on image-domain-warping (IDW) is presented that automatically synthesizes new views directly from S3D video and functions completely. IDW relies on an automatic and robust estimation of sparse disparities and image saliency information, and enforces target disparities in synthesized images using an image warping framework. Two configurations of the view synthesizer in the scope of a transmission and view synthesis framework are analyzed and evaluated. A transmission and view synthesis system that uses IDW is recently submitted to MPEG's call for proposals on 3D video technology, where it is ranked among the four best performing proposals.

  10. The rationale for microcirculatory guided fluid therapy.

    PubMed

    Ince, Can

    2014-06-01

    The ultimate purpose of fluid administration in states of hypovolemia is to correct cardiac output to improve microcirculatory perfusion and tissue oxygenation. Observation of the microcirculation using handheld microscopes gives insight into the nature of convective and diffusive defect in hypovolemia. The purpose of this article is to introduce a new platform for hemodynamic-targeted fluid therapy based on the correction of tissue and microcirculatory perfusion assumed to be at risk during hypovolemia. Targeting systemic hemodynamic targets and/or clinical surrogates of hypovolemia gives inadequate guarantee for the correction of tissue perfusion by fluid therapy especially in conditions of distributive shock as occur in inflammation and sepsis. Findings are presented, which support the idea that only clinical signs of hypovolemia associated with low microcirculatory flow can be expected to benefit from fluid therapy and that fluid overload causes a defect in the diffusion of oxygen transport. We hypothesized that the optimal amount of fluid needed for correction of hypovolemia is defined by a physiologically based functional microcirculatory hemodynamic platform where convection and diffusion need to be optimized. Future clinical trials using handheld microscopes able to automatically evaluate the microcirculation at the bedside will show whether such a platform will indeed optimize fluid therapy.

  11. Effects of external and gap mean flows on sound transmission through a double-wall sandwich panel

    NASA Astrophysics Data System (ADS)

    Liu, Yu; Sebastian, Alexis

    2015-05-01

    This paper studies analytically the effects of an external mean flow and an internal gap mean flow on sound transmission through a double-wall sandwich panel lined with poroelastic materials. Biot's theory is employed to describe wave propagation in poroelastic materials, and the transfer matrix method with three types of boundary conditions is applied to solve the system simultaneously. The random incidence transmission loss in a diffuse field is calculated numerically, and the limiting angle of incidence due to total internal reflection is discussed in detail. The numerical predictions suggest that the sound insulation performance of such a double-wall panel is enhanced considerably by both external and gap mean flows particularly in the high-frequency range. Similar effects on transmission loss are observed for the two mean flows. It is shown that the effect of the gap mean flow depends on flow velocity, flow direction, gap depth and fluid properties and also that the fluid properties within the gap appear to influence the transmission loss more effectively than the gap flow. Despite the implementation difficulty in practice, an internal gap flow provides more design space for tuning the sound insulation performance of a double-wall sandwich panel and has great potential for active/passive noise control.

  12. Advanced Fuel Development and Fuel Combustion

    DTIC Science & Technology

    1997-08-01

    development of supercritical fluid extraction techniques for gums and deposits; 5) generation of homogeneous, liquid phase kinetic data on the consumption...Gas Chromatography 12 TASK NO. 09: Assessment of the Friction Characteristics and Scuffing Potential of a Helicopter Transmission Lubricant...stations can easily be contaminated by personnel improperly disposing of other materials such as mineral oil lubricants, silicone oils, hydraulic fluids

  13. 33 CFR 169.235 - What exemptions are there from reporting?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... SECURITY (CONTINUED) PORTS AND WATERWAYS SAFETY SHIP REPORTING SYSTEMS Transmission of Long Range Identification and Tracking Information § 169.235 What exemptions are there from reporting? A ship is exempt from this subpart if it is— (a) Fitted with an operating automatic identification system (AIS), under 33 CFR...

  14. 33 CFR 169.235 - What exemptions are there from reporting?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... SECURITY (CONTINUED) PORTS AND WATERWAYS SAFETY SHIP REPORTING SYSTEMS Transmission of Long Range Identification and Tracking Information § 169.235 What exemptions are there from reporting? A ship is exempt from this subpart if it is— (a) Fitted with an operating automatic identification system (AIS), under 33 CFR...

  15. 33 CFR 169.235 - What exemptions are there from reporting?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... SECURITY (CONTINUED) PORTS AND WATERWAYS SAFETY SHIP REPORTING SYSTEMS Transmission of Long Range Identification and Tracking Information § 169.235 What exemptions are there from reporting? A ship is exempt from this subpart if it is— (a) Fitted with an operating automatic identification system (AIS), under 33 CFR...

  16. 33 CFR 169.235 - What exemptions are there from reporting?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... SECURITY (CONTINUED) PORTS AND WATERWAYS SAFETY SHIP REPORTING SYSTEMS Transmission of Long Range Identification and Tracking Information § 169.235 What exemptions are there from reporting? A ship is exempt from this subpart if it is— (a) Fitted with an operating automatic identification system (AIS), under 33 CFR...

  17. 33 CFR 169.235 - What exemptions are there from reporting?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... SECURITY (CONTINUED) PORTS AND WATERWAYS SAFETY SHIP REPORTING SYSTEMS Transmission of Long Range... this subpart if it is— (a) Fitted with an operating automatic identification system (AIS), under 33 CFR 164.46, and operates only within 20 nautical miles of the United States baseline, (b) A warship, naval...

  18. In situ realization of asymmetric ratchet structures within microchannels by directionally guided light transmission and their directional flow behavior.

    PubMed

    Bae, Won-Gyu; Kim, Sang Moon; Choi, Se-Jin; Oh, Sang Geun; Yoon, Hyunsik; Char, Kookheon; Suh, Kahp Y

    2014-05-01

    An asymmetric ratchet structure within microchannels is demonstrated by directionally guided light transmission for controlled liquid flow. A direct and facile method is presented to realize programmed asymmetric structures, which control the fluid direction and speed. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. The Nature of Exposure Drives Transmission of Nipah Viruses from Malaysia and Bangladesh in Ferrets

    PubMed Central

    Clayton, Bronwyn A.; Middleton, Deborah; Arkinstall, Rachel; Frazer, Leah; Wang, Lin-Fa; Marsh, Glenn A.

    2016-01-01

    Person-to-person transmission is a key feature of human Nipah virus outbreaks in Bangladesh. In contrast, in an outbreak of Nipah virus in Malaysia, people acquired infections from pigs. It is not known whether this important epidemiological difference is driven primarily by differences between NiV Bangladesh (NiV-BD) and Malaysia (NiV-MY) at a virus level, or by environmental or host factors. In a time course study, ferrets were oronasally exposed to equivalent doses of NiV-BD or NiV-MY. More rapid onset of productive infection and higher levels of virus replication in respiratory tract tissues were seen for NiV-BD compared to NiV-MY, corroborating our previous report of increased oral shedding of NiV-BD in ferrets and suggesting a contributory mechanism for increased NiV-BD transmission between people compared to NiV-MY. However, we recognize that transmission occurs within a social and environmental framework that may have an important and differentiating role in NiV transmission rates. With this in mind, ferret-to-ferret transmission of NiV-BD and NiV-MY was assessed under differing viral exposure conditions. Transmission was not identified for either virus when naïve ferrets were cohoused with experimentally-infected animals. In contrast, all naïve ferrets developed acute infection following assisted and direct exposure to oronasal fluid from animals that were shedding either NiV-BD or NiV-MY. Our findings for ferrets indicate that, although NiV-BD may be shed at higher levels than NiV-MY, transmission risk may be equivalently low under exposure conditions provided by cohabitation alone. In contrast, active transfer of infected bodily fluids consistently results in transmission, regardless of the virus strain. These observations suggest that the risk of NiV transmission is underpinned by social and environmental factors, and will have practical implications for managing transmission risk during outbreaks of human disease. PMID:27341030

  20. The Nature of Exposure Drives Transmission of Nipah Viruses from Malaysia and Bangladesh in Ferrets.

    PubMed

    Clayton, Bronwyn A; Middleton, Deborah; Arkinstall, Rachel; Frazer, Leah; Wang, Lin-Fa; Marsh, Glenn A

    2016-06-01

    Person-to-person transmission is a key feature of human Nipah virus outbreaks in Bangladesh. In contrast, in an outbreak of Nipah virus in Malaysia, people acquired infections from pigs. It is not known whether this important epidemiological difference is driven primarily by differences between NiV Bangladesh (NiV-BD) and Malaysia (NiV-MY) at a virus level, or by environmental or host factors. In a time course study, ferrets were oronasally exposed to equivalent doses of NiV-BD or NiV-MY. More rapid onset of productive infection and higher levels of virus replication in respiratory tract tissues were seen for NiV-BD compared to NiV-MY, corroborating our previous report of increased oral shedding of NiV-BD in ferrets and suggesting a contributory mechanism for increased NiV-BD transmission between people compared to NiV-MY. However, we recognize that transmission occurs within a social and environmental framework that may have an important and differentiating role in NiV transmission rates. With this in mind, ferret-to-ferret transmission of NiV-BD and NiV-MY was assessed under differing viral exposure conditions. Transmission was not identified for either virus when naïve ferrets were cohoused with experimentally-infected animals. In contrast, all naïve ferrets developed acute infection following assisted and direct exposure to oronasal fluid from animals that were shedding either NiV-BD or NiV-MY. Our findings for ferrets indicate that, although NiV-BD may be shed at higher levels than NiV-MY, transmission risk may be equivalently low under exposure conditions provided by cohabitation alone. In contrast, active transfer of infected bodily fluids consistently results in transmission, regardless of the virus strain. These observations suggest that the risk of NiV transmission is underpinned by social and environmental factors, and will have practical implications for managing transmission risk during outbreaks of human disease.

  1. A versatile valving toolkit for automating fluidic operations in paper microfluidic devices.

    PubMed

    Toley, Bhushan J; Wang, Jessica A; Gupta, Mayuri; Buser, Joshua R; Lafleur, Lisa K; Lutz, Barry R; Fu, Elain; Yager, Paul

    2015-03-21

    Failure to utilize valving and automation techniques has restricted the complexity of fluidic operations that can be performed in paper microfluidic devices. We developed a toolkit of paper microfluidic valves and methods for automatic valve actuation using movable paper strips and fluid-triggered expanding elements. To the best of our knowledge, this is the first functional demonstration of this valving strategy in paper microfluidics. After introduction of fluids on devices, valves can actuate automatically after a) a certain period of time, or b) the passage of a certain volume of fluid. Timing of valve actuation can be tuned with greater than 8.5% accuracy by changing lengths of timing wicks, and we present timed on-valves, off-valves, and diversion (channel-switching) valves. The actuators require ~30 μl fluid to actuate and the time required to switch from one state to another ranges from ~5 s for short to ~50 s for longer wicks. For volume-metered actuation, the size of a metering pad can be adjusted to tune actuation volume, and we present two methods - both methods can achieve greater than 9% accuracy. Finally, we demonstrate the use of these valves in a device that conducts a multi-step assay for the detection of the malaria protein PfHRP2. Although slightly more complex than devices that do not have moving parts, this valving and automation toolkit considerably expands the capabilities of paper microfluidic devices. Components of this toolkit can be used to conduct arbitrarily complex, multi-step fluidic operations on paper-based devices, as demonstrated in the malaria assay device.

  2. A versatile valving toolkit for automating fluidic operations in paper microfluidic devices

    PubMed Central

    Toley, Bhushan J.; Wang, Jessica A.; Gupta, Mayuri; Buser, Joshua R.; Lafleur, Lisa K.; Lutz, Barry R.; Fu, Elain; Yager, Paul

    2015-01-01

    Failure to utilize valving and automation techniques has restricted the complexity of fluidic operations that can be performed in paper microfluidic devices. We developed a toolkit of paper microfluidic valves and methods for automatic valve actuation using movable paper strips and fluid-triggered expanding elements. To the best of our knowledge, this is the first functional demonstration of this valving strategy in paper microfluidics. After introduction of fluids on devices, valves can actuate automatically a) after a certain period of time, or b) after the passage of a certain volume of fluid. Timing of valve actuation can be tuned with greater than 8.5% accuracy by changing lengths of timing wicks, and we present timed on-valves, off-valves, and diversion (channel-switching) valves. The actuators require ~30 μl fluid to actuate and the time required to switch from one state to another ranges from ~5 s for short to ~50s for longer wicks. For volume-metered actuation, the size of a metering pad can be adjusted to tune actuation volume, and we present two methods – both methods can achieve greater than 9% accuracy. Finally, we demonstrate the use of these valves in a device that conducts a multi-step assay for the detection of the malaria protein PfHRP2. Although slightly more complex than devices that do not have moving parts, this valving and automation toolkit considerably expands the capabilities of paper microfluidic devices. Components of this toolkit can be used to conduct arbitrarily complex, multi-step fluidic operations on paper-based devices, as demonstrated in the malaria assay device. PMID:25606810

  3. Scattering of ultrasonic waves from porous piezoelectric multilayered structures immersed in a fluid

    NASA Astrophysics Data System (ADS)

    Vashishth, Anil K.; Gupta, Vishakha

    2012-12-01

    The interest in porous piezoelectric materials is due to the demand for low-frequency hydrophone/actuator devices for use in underwater acoustic systems and other oceanographic applications. Porosity decreases the acoustic impedance, thus improving the transfer of acoustic energy to water or biological tissues. The impedance mismatching problem between the dense piezoelectric materials and the surrounding medium can be solved by inclusion of porosity in dense piezoceramics. The complete description of acoustic propagation in a multilayered system is of great interest in a variety of applications, such as non-destructive evaluation and acoustic design, and there is need for a flexible model that can describe the reflection and transmission of ultrasonic waves in these media. The present paper elaborates a theoretical model, based on the transfer matrix method, for describing reflection and transmission of plane elastic waves through a porous piezoelectric laminated plate, immersed in a fluid. The analytical expressions for the reflection coefficient, transmission coefficient and acoustic impedance are derived. The effects of frequency, angle of incidence, number of layers, layer thickness and porosity are observed numerically for different configurations. The results obtained are deduced for the piezoelectric laminated structure, piezoelectric layer and poro-elastic layer immersed in a fluid, which are in agreement with earlier established results and experimental studies.

  4. Large area and low power dielectrowetting optical shutter with local deterministic fluid film breakup

    NASA Astrophysics Data System (ADS)

    Zhao, R.; Cumby, B.; Russell, A.; Heikenfeld, J.

    2013-11-01

    A large area (>10 cm2) and low-power (0.1-10 Hz AC voltage, ˜10's μW/cm2) dielectrowetting optical shutter requiring no pixelation is demonstrated. The device consists of 40 μm interdigitated electrodes covered by fluid splitting features and a hydrophobic fluoropolymer. When voltage is removed, the fluid splitting features initiate breakup of the fluid film into small droplets resulting in ˜80% transmission. Both the dielectrowetting and fluid splitting follow theory, allowing prediction of alternate designs and further improved performance. Advantages include scalability, optical polarization independence, high contrast ratio, fast response, and simple construction, which could be of use in switchable windows or transparent digital signage.

  5. Reciprocal relations for transmission coefficients - Theory and application

    NASA Technical Reports Server (NTRS)

    Qu, Jianmin; Achenbach, Jan D.; Roberts, Ronald A.

    1989-01-01

    The authors present a rigorous proof of certain intuitively plausible reciprocal relations for time harmonic plane-wave transmission and reflection at the interface between a fluid and an anisotropic elastic solid. Precise forms of the reciprocity relations for the transmission coefficients and for the transmitted energy fluxes are derived, based on the reciprocity theorem of elastodynamics. It is shown that the reciprocity relations can be used in conjunction with measured values of peak amplitudes for transmission through a slab of the solid (water-solid-water) to obtain the water-solid coefficients. Experiments were performed for a slab of a unidirectional fiber-reinforced composite. Good agreement of the experimentally measured transmission coefficients with theoretical values was obtained.

  6. Adaptive transmission based on multi-relay selection and rate-compatible LDPC codes

    NASA Astrophysics Data System (ADS)

    Su, Hualing; He, Yucheng; Zhou, Lin

    2017-08-01

    In order to adapt to the dynamical changeable channel condition and improve the transmissive reliability of the system, a cooperation system of rate-compatible low density parity check (RC-LDPC) codes combining with multi-relay selection protocol is proposed. In traditional relay selection protocol, only the channel state information (CSI) of source-relay and the CSI of relay-destination has been considered. The multi-relay selection protocol proposed by this paper takes the CSI between relays into extra account in order to obtain more chances of collabration. Additionally, the idea of hybrid automatic request retransmission (HARQ) and rate-compatible are introduced. Simulation results show that the transmissive reliability of the system can be significantly improved by the proposed protocol.

  7. Two stage kickdown control system for a motor vehicle automatic transmission

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Higashi, H.; Waki, K.; Fukuiri, M.

    This patent describes a vehicle automatic transmission including a hydraulic torque converter and a transmission gear mechanism connected with the torque converter and having at least three gear stages of different gear ratios for forward drive. A principal feature of this system as described is a friction means for selecting one of the gear stages as well as a kickdown control means consisting of the first shift down circuit means for control of the friction means so that the transmission gear mechanism is shifted downward. A solenoid kick down means within the modality of the first shift down circuit andmore » a kick down switch means actuated by an engine control member when it is moved to a full power position provides control of the kick down solenoid and the effecting of a down shift. The shift down control means is composed of a second shift down circuit means for controlling the friction means so shift down occurs. The shift down solenoid contained in the second shift down circuit means in conjunction with a shift down switch actuated by engine control member movement to a position spaced a predetermined distance from the full power position control the shift down solenoid to effect a shift down. Thus this mechanism is actuated earlier than the kickdown switch means when the engine control member is moved toward the full power position. A time delay means from the time of actuation of the shift down switch means and controlling kickdown switch activation is also described.« less

  8. Superphobicity/philicity Janus Fabrics with Switchable, Spontaneous, Directional Transport Ability to Water and Oil Fluids

    PubMed Central

    Zhou, Hua; Wang, Hongxia; Niu, Haitao; Lin, Tong

    2013-01-01

    Herein we demonstrate that switchable, spontaneous, directional-transport ability to both water and oil fluids can be created on fabric materials through wet-chemistry coating and successive UV irradiation treatment. When the fabric showed directional transport to a liquid, it prevented liquids of higher surface tension from penetration, but allowed liquids of lower surface tension to permeate, from either side. The directional transport ability can be switched from one fluid to another simply by heating the fabric at an elevated temperature and then re-irradiating the fabric with UV light for required period of time. By attaching liquid drops vertically upwards to a horizontally-laid fabric, we further demonstrated that this novel directional fluid transport was an automatic process driven by surface property alone, irrespective of gravity's effect. This novel fabric may be useful for development of “smart” textiles and functional membranes for various applications. PMID:24129357

  9. Superphobicity/philicity Janus Fabrics with Switchable, Spontaneous, Directional Transport Ability to Water and Oil Fluids

    NASA Astrophysics Data System (ADS)

    Zhou, Hua; Wang, Hongxia; Niu, Haitao; Lin, Tong

    2013-10-01

    Herein we demonstrate that switchable, spontaneous, directional-transport ability to both water and oil fluids can be created on fabric materials through wet-chemistry coating and successive UV irradiation treatment. When the fabric showed directional transport to a liquid, it prevented liquids of higher surface tension from penetration, but allowed liquids of lower surface tension to permeate, from either side. The directional transport ability can be switched from one fluid to another simply by heating the fabric at an elevated temperature and then re-irradiating the fabric with UV light for required period of time. By attaching liquid drops vertically upwards to a horizontally-laid fabric, we further demonstrated that this novel directional fluid transport was an automatic process driven by surface property alone, irrespective of gravity's effect. This novel fabric may be useful for development of ``smart'' textiles and functional membranes for various applications.

  10. Infectious Prions in the Pregnancy Microenvironment of Chronic Wasting Disease-Infected Reeves' Muntjac Deer.

    PubMed

    Nalls, Amy V; McNulty, Erin; Hoover, Clare E; Pulscher, Laura A; Hoover, Edward A; Mathiason, Candace K

    2017-08-01

    Ample evidence exists for the presence of infectious agents at the maternal-fetal interface, often with grave outcomes to the developing fetus (i.e., Zika virus, brucella, cytomegalovirus, and toxoplasma). While less studied, pregnancy-related transmissible spongiform encephalopathies (TSEs) have been implicated in several species, including humans. Our previous work has shown that prions can be transferred from mother to offspring, resulting in the development of clinical TSE disease in offspring born to muntjac dams infected with chronic wasting disease (CWD) (1). We further demonstrated protein misfolding cyclic amplification (PMCA)-competent prions within the female reproductive tract and in fetal tissues harvested from CWD experimentally and naturally exposed cervids (1, 2). To assess whether the PMCA-competent prions residing at the maternal-fetal interface were infectious and to determine if the real-time quaking-induced conversion (RT-QuIC) methodology may enhance our ability to detect amyloid fibrils within the pregnancy microenvironment, we employed a mouse bioassay and RT-QuIC. In this study, we have demonstrated RT-QuIC seeding activity in uterus, placentome, ovary, and amniotic fluid but not in allantoic fluids harvested from CWD-infected Reeves' muntjac dams showing clinical signs of infection (clinically CWD-infected) and in some placentomes from pre-clinically CWD-infected dams. Prion infectivity was confirmed within the uterus, amniotic fluid, and the placentome, the semipermeable interface that sustains the developing fetus, of CWD-infected dams. This is the first report of prion infectivity within the cervid pregnancy microenvironment, revealing a source of fetal CWD exposure prior to the birthing process, maternal grooming, or encounters with contaminated environments. IMPORTANCE The facile dissemination of chronic wasting disease within captive and free-range cervid populations has led to questions regarding the transmission dynamics of this disease. Direct contact with infected animals and indirect contact with infectious prions in bodily fluids and contaminated environments are suspected to explain the majority of this transmission. A third mode of transmission, from mother to offspring, may be underappreciated. The presence of pregnancy-related prion infectivity within the uterus, amniotic fluid, and the placental structure reveals that the developing fetus is exposed to a source of prions long before exposure to the infectious agent during and after the birthing process or via contact with contaminated environments. These findings have impact on our current concept of CWD disease transmission. Copyright © 2017 American Society for Microbiology.

  11. Control device for prosthetic urinary sphincter cuff

    NASA Technical Reports Server (NTRS)

    Reinicke, Robert H. (Inventor)

    1983-01-01

    A device for controlling flow of fluid to and from a resilient inflatable cuff implanted about the urethra to control flow of urine therethrough. The device comprises a flexible bulb reservoir and a control unit that includes a manually operated valve that opens automatically when the bulb is squeezed to force fluid into the cuff for closing the urethra. The control unit also includes a movable valve seat member having a relatively large area exposed to pressure of fluid in a chamber that is connected to the cuff and which moves to a position in which the valve member is unseated by an abutment when fluid pressure in the chamber exceeds a predetermined value to thereby relieve excess fluid pressure in the cuff. The arrangement is such that the valve element is held closed against the seat member by the full differential in fluid pressures acting on both sides of the valve element until the seat member is moved away from the valve element to thus insure positive closing of the valve element until the seat member is moved out of engagement with the valve element by excess pressure differential.

  12. Sound transmission analysis of partially treated MR fluid-based sandwich panels using finite element method

    NASA Astrophysics Data System (ADS)

    Hemmatian, M.; Sedaghati, R.

    2017-04-01

    This study aims at developing a finite element model to predict the sound transmission loss (STL) of a multilayer panel partially treated with a Magnetorheological (MR) fluid core layer. MR fluids are smart materials with promising controllable rheological characteristics in which the application of an external magnetic field instantly changes their rheological properties. Partial treatment of sandwich panels with MR fluid core layer provides an opportunity to change stiffness and damping of the structure without significantly increasing the mass. The STL of a finite sandwich panel partially treated with MR fluid is modeled using the finite element (FE) method. Circular sandwich panels with clamped boundary condition and elastic face sheets in which the core layer is segmented circumferentially is considered. The MR fluid core layer is considered as a viscoelastic material with complex shear modulus with the magnetic field and frequency dependent storage and loss moduli. Neglecting the effect of the panel's vibration on the pressure forcing function, the work done by the acoustic pressure is expressed as a function of the blocked pressure in order to calculate the force vector in the equation of the motion of the panel. The governing finite element equation of motion of the MR sandwich panel is then developed to predict the transverse vibration of the panel which can then be utilized to obtain the radiated sound using Green's function. The developed model is used to conduct a systematic parametric study on the effect of different locations of MR fluid treatment on the natural frequencies and the STL.

  13. Method and apparatus for automatically generating airfoil performance tables

    NASA Technical Reports Server (NTRS)

    van Dam, Cornelis P. (Inventor); Mayda, Edward A. (Inventor); Strawn, Roger Clayton (Inventor)

    2006-01-01

    One embodiment of the present invention provides a system that facilitates automatically generating a performance table for an object, wherein the object is subject to fluid flow. The system operates by first receiving a description of the object and testing parameters for the object. The system executes a flow solver using the testing parameters and the description of the object to produce an output. Next, the system determines if the output of the flow solver indicates negative density or pressure. If not, the system analyzes the output to determine if the output is converging. If converging, the system writes the output to the performance table for the object.

  14. Automatically operable self-leveling load table

    NASA Technical Reports Server (NTRS)

    Burch, J. L. (Inventor)

    1974-01-01

    A self-leveling load table is described which is automatically maintained level by selectively opening and closing solenoid valves for inserting and removing air from chambers under the table. The table is floated in a fluid by nine air chambers beneath the top of the table. These chambers are open at the bottom and four oppositely located chambers are used for leveling the table by having the air increased or decreased by means of a flexible hose. Air bearing pendulums are used for selectively energizing solenoid valves which either apply pressurized air to the chamber or evacuate air from the chamber by means of a vacuum source.

  15. Variable frame rate transmission - A review of methodology and application to narrow-band LPC speech coding

    NASA Astrophysics Data System (ADS)

    Viswanathan, V. R.; Makhoul, J.; Schwartz, R. M.; Huggins, A. W. F.

    1982-04-01

    The variable frame rate (VFR) transmission methodology developed, implemented, and tested in the years 1973-1978 for efficiently transmitting linear predictive coding (LPC) vocoder parameters extracted from the input speech at a fixed frame rate is reviewed. With the VFR method, parameters are transmitted only when their values have changed sufficiently over the interval since their preceding transmission. Two distinct approaches to automatic implementation of the VFR method are discussed. The first bases the transmission decisions on comparisons between the parameter values of the present frame and the last transmitted frame. The second, which is based on a functional perceptual model of speech, compares the parameter values of all the frames that lie in the interval between the present frame and the last transmitted frame against a linear model of parameter variation over that interval. Also considered is the application of VFR transmission to the design of narrow-band LPC speech coders with average bit rates of 2000-2400 bts/s.

  16. Design and control of electromagnetic clutch actuation system for automated manual transmission

    NASA Astrophysics Data System (ADS)

    Ranjan, Ashish; Prasanth, S.; Cherian, Fenin; Baskar, P.

    2017-11-01

    There is a growing interest towards Automatic Transmission in India as it provides better comfort and drivability. But the high cost of this system is limiting itself to be successful in the Indian markets. Due to this, Automated Manual Transmission (AMT) is considered which provides a better solution towards automation as it enhances the drivability and fuel consumption characteristics of a manual transmission at lower costs. However, torque lag and comfort are major issues with AMT which can be addressed by reducing the shift time. In this paper we describe an Electromagnetic Linear Clutch Actuator as a replacement to current electrohydraulic and electromechanical actuator. A control system for the actuator is presented and a clutch engagement strategy is also implemented which reduces the engagement time to 0.78 seconds while reducing jerk and torque lag. The actuator and control system is simulated on a MATLAB Simulink and agreeable results have been obtained.

  17. Nonlinear force feedback control of piezoelectric-hydraulic pump actuator for automotive transmission shift control

    NASA Astrophysics Data System (ADS)

    Kim, Gi-Woo; Wang, K. W.

    2008-03-01

    In recent years, researchers have investigated the feasibility of utilizing piezoelectric-hydraulic pump based actuation systems for automotive transmission controls. This new concept could eventually reduce the complexity, weight, and fuel consumption of the current transmissions. In this research, we focus on how to utilize this new approach on the shift control of automatic transmissions (AT), which generally requires pressure profiling for friction elements during the operation. To illustrate the concept, we will consider the 1--> 2 up shift control using band brake friction elements. In order to perform the actuation force tracking for AT shift control, nonlinear force feedback control laws are designed based on the sliding mode theory for the given nonlinear system. This paper will describe the modeling of the band brake actuation system, the design of the nonlinear force feedback controller, and simulation and experimental results for demonstration of the new concept.

  18. Design studies of continuously variable transmissions for electric vehicles

    NASA Technical Reports Server (NTRS)

    Parker, R. J.; Loewenthal, S. H.; Fischer, G. K.

    1981-01-01

    Preliminary design studies were performed on four continuously variable transmission (CVT) concepts for use with a flywheel equipped electric vehicle of 1700 kg gross weight. Requirements of the CVT's were a maximum torque of 450 N-m (330 lb-ft), a maximum output power of 75 kW (100 hp), and a flywheel speed range of 28,000 to 14,000 rpm. Efficiency, size, weight, cost, reliability, maintainability, and controls were evaluated for each of the four concepts which included a steel V-belt type, a flat rubber belt type, a toroidal traction type, and a cone roller traction type. All CVT's exhibited relatively high calculated efficiencies (68 percent to 97 percent) over a broad range of vehicle operating conditions. Estimated weight and size of these transmissions were comparable to or less than equivalent automatic transmission. The design of each concept was carried through the design layout stage.

  19. Model structure identification for wastewater treatment simulation based on computational fluid dynamics.

    PubMed

    Alex, J; Kolisch, G; Krause, K

    2002-01-01

    The objective of this presented project is to use the results of an CFD simulation to automatically, systematically and reliably generate an appropriate model structure for simulation of the biological processes using CSTR activated sludge compartments. Models and dynamic simulation have become important tools for research but also increasingly for the design and optimisation of wastewater treatment plants. Besides the biological models several cases are reported about the application of computational fluid dynamics ICFD) to wastewater treatment plants. One aim of the presented method to derive model structures from CFD results is to exclude the influence of empirical structure selection to the result of dynamic simulations studies of WWTPs. The second application of the approach developed is the analysis of badly performing treatment plants where the suspicion arises that bad flow behaviour such as short cut flows is part of the problem. The method suggested requires as the first step the calculation of fluid dynamics of the biological treatment step at different loading situations by use of 3-dimensional CFD simulation. The result of this information is used to generate a suitable model structure for conventional dynamic simulation of the treatment plant by use of a number of CSTR modules with a pattern of exchange flows between the tanks automatically. The method is explained in detail and the application to the WWTP Wuppertal Buchenhofen is presented.

  20. Shedding of Japanese Encephalitis Virus in Oral Fluid of Infected Swine.

    PubMed

    Lyons, Amy C; Huang, Yan-Jang S; Park, So Lee; Ayers, Victoria B; Hettenbach, Susan M; Higgs, Stephen; McVey, D Scott; Noronha, Leela; Hsu, Wei-Wen; Vanlandingham, Dana L

    2018-05-09

    Japanese encephalitis virus (JEV) is a zoonotic mosquito-borne flavivirus endemic in the Asia-Pacific region. Maintenance of JEV in nature involves enzootic transmission by competent Culex mosquitoes among susceptible avian and swine species. Historically, JEV has been regarded as one of the most important arthropod-borne viruses in Southeast Asia. Oronasal shedding of JEV from infected amplification hosts was not recognized until the recent discovery of vector-free transmission of JEV among domestic pigs. In this study, oral shedding of JEV was characterized in domestic pigs and miniature swine representing the feral phenotype. A rope-based sampling method followed by the detection of viral RNA using RT-qPCR allowed the collection and detection of JEV in oral fluid samples collected from intradermally challenged animals. The results suggest that the shedding of JEV in oral fluid can be readily detected by molecular diagnostic assays at the acute phase of infection. It also demonstrates the feasibility of this technique for the diagnosis and surveillance of JEV in swine species.

  1. Effect of supercritical fluid density on nanoencapsulated drug particle size using the supercritical antisolvent method.

    PubMed

    Kalani, Mahshid; Yunus, Robiah

    2012-01-01

    The reported work demonstrates and discusses the effect of supercritical fluid density (pressure and temperature of supercritical fluid carbon dioxide) on particle size and distribution using the supercritical antisolvent (SAS) method in the purpose of drug encapsulation. In this study, paracetamol was encapsulated inside L-polylactic acid, a semicrystalline polymer, with different process parameters, including pressure and temperature, using the SAS process. The morphology and particle size of the prepared nanoparticles were determined by scanning electron microscopy and transmission electron microscopy. The results revealed that increasing temperature enhanced mean particle size due to the plasticizing effect. Furthermore, increasing pressure enhanced molecular interaction and solubility; thus, particle size was reduced. Transmission electron microscopy images defined the internal structure of nanoparticles. Thermal characteristics of nanoparticles were also investigated via differential scanning calorimetry. Furthermore, X-ray diffraction pattern revealed the changes in crystallinity structure during the SAS process. In vitro drug release analysis determined the sustained release of paracetamol in over 4 weeks.

  2. Effect of supercritical fluid density on nanoencapsulated drug particle size using the supercritical antisolvent method

    PubMed Central

    Kalani, Mahshid; Yunus, Robiah

    2012-01-01

    The reported work demonstrates and discusses the effect of supercritical fluid density (pressure and temperature of supercritical fluid carbon dioxide) on particle size and distribution using the supercritical antisolvent (SAS) method in the purpose of drug encapsulation. In this study, paracetamol was encapsulated inside L-polylactic acid, a semicrystalline polymer, with different process parameters, including pressure and temperature, using the SAS process. The morphology and particle size of the prepared nanoparticles were determined by scanning electron microscopy and transmission electron microscopy. The results revealed that increasing temperature enhanced mean particle size due to the plasticizing effect. Furthermore, increasing pressure enhanced molecular interaction and solubility; thus, particle size was reduced. Transmission electron microscopy images defined the internal structure of nanoparticles. Thermal characteristics of nanoparticles were also investigated via differential scanning calorimetry. Furthermore, X-ray diffraction pattern revealed the changes in crystallinity structure during the SAS process. In vitro drug release analysis determined the sustained release of paracetamol in over 4 weeks. PMID:22619552

  3. BK virus has tropism for human salivary gland cells in vitro: Implications for transmission

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeffers, Liesl K.; Madden, Vicki; Webster-Cyriaque, Jennifer, E-mail: jennifer@med.unc.ed

    Background: In this study, it was determined that BKV is shed in saliva and an in vitro model system was developed whereby BKV can productively infect both submandibular (HSG) and parotid (HSY) salivary gland cell lines. Results: BKV was detected in oral fluids using quantitative real-time PCR (QRTPCR). BKV infection was determined using quantitative RT-PCR, immunofluorescence and immunoblotting assays. The infectivity of BKV was inhibited by pre-incubation of the virus with gangliosides that saturated the major capsid protein, VP1, halting receptor mediated BKV entry into salivary gland cells. Examination of infected cultures by transmission electron microscopy revealed 45-50 nm BKmore » virions clearly visible within the cells. Subsequent to infection, encapsidated BK virus was detected in the supernatant. Conclusion: We thus demonstrated that BKV was detected in oral fluids and that BK infection and replication occur in vitro in salivary gland cells. These data collectively suggest the potential for BKV oral route of transmission and oral pathogenesis.« less

  4. Automatic cerebrospinal fluid segmentation in non-contrast CT images using a 3D convolutional network

    NASA Astrophysics Data System (ADS)

    Patel, Ajay; van de Leemput, Sil C.; Prokop, Mathias; van Ginneken, Bram; Manniesing, Rashindra

    2017-03-01

    Segmentation of anatomical structures is fundamental in the development of computer aided diagnosis systems for cerebral pathologies. Manual annotations are laborious, time consuming and subject to human error and observer variability. Accurate quantification of cerebrospinal fluid (CSF) can be employed as a morphometric measure for diagnosis and patient outcome prediction. However, segmenting CSF in non-contrast CT images is complicated by low soft tissue contrast and image noise. In this paper we propose a state-of-the-art method using a multi-scale three-dimensional (3D) fully convolutional neural network (CNN) to automatically segment all CSF within the cranial cavity. The method is trained on a small dataset comprised of four manually annotated cerebral CT images. Quantitative evaluation of a separate test dataset of four images shows a mean Dice similarity coefficient of 0.87 +/- 0.01 and mean absolute volume difference of 4.77 +/- 2.70 %. The average prediction time was 68 seconds. Our method allows for fast and fully automated 3D segmentation of cerebral CSF in non-contrast CT, and shows promising results despite a limited amount of training data.

  5. Method and system for real-time analysis of biosensor data

    DOEpatents

    Greenbaum, Elias; Rodriguez, Jr., Miguel

    2014-08-19

    A method of biosensor-based detection of toxins includes the steps of providing a fluid to be analyzed having a plurality of photosynthetic organisms therein, wherein chemical, biological or radiological agents alter a nominal photosynthetic activity of the photosynthetic organisms. At a first time a measured photosynthetic activity curve is obtained from the photosynthetic organisms. The measured curve is automatically compared to a reference photosynthetic activity curve to determine differences therebetween. The presence of the chemical, biological or radiological agents, or precursors thereof, are then identified if present in the fluid using the differences.

  6. [DIAGNOSTIC VALUE OF COMBINED USE OF COMBINED METHOD OF ENZYME IMMUNOASSAY AND POLYMERASE CHAIN REACTION TO DETECT OF INTRAUTERINE FETAL INFECTION BY PARVOVIRUS B19].

    PubMed

    Bondarenko, N P; Lakatosh, V P; Lakatosh, P V; Malanchuk, O B; Poladich, I V

    2015-01-01

    The combined method of diagnosis parvovirus infection during pregnancy by maternal serum enzyme immunoassay and deoxyribonucleic acid isolation parvovirus B19 polymerase chain reaction in amnniotic fluid and fetal cord blood newborns, can diagnose vertical transmission and anticipate a negative effect on the fetus parvovirus. Lack of maternal IgM antibodies in serum due to parvovirus seroconversion during pregnancy does not exclude the persistence of the virus in the fetus. To analyze the diagnostic value of the method for determining the LHP parvovirus B19 DNA in the amniotic fluid, umbilical cord blood of newborns to determine vertical transmission of parvovirus infection when infected mothers B19 during pregnancy.

  7. Development of wireless brain computer interface with embedded multitask scheduling and its application on real-time driver's drowsiness detection and warning.

    PubMed

    Lin, Chin-Teng; Chen, Yu-Chieh; Huang, Teng-Yi; Chiu, Tien-Ting; Ko, Li-Wei; Liang, Sheng-Fu; Hsieh, Hung-Yi; Hsu, Shang-Hwa; Duann, Jeng-Ren

    2008-05-01

    Biomedical signal monitoring systems have been rapidly advanced with electronic and information technologies in recent years. However, most of the existing physiological signal monitoring systems can only record the signals without the capability of automatic analysis. In this paper, we proposed a novel brain-computer interface (BCI) system that can acquire and analyze electroencephalogram (EEG) signals in real-time to monitor human physiological as well as cognitive states, and, in turn, provide warning signals to the users when needed. The BCI system consists of a four-channel biosignal acquisition/amplification module, a wireless transmission module, a dual-core signal processing unit, and a host system for display and storage. The embedded dual-core processing system with multitask scheduling capability was proposed to acquire and process the input EEG signals in real time. In addition, the wireless transmission module, which eliminates the inconvenience of wiring, can be switched between radio frequency (RF) and Bluetooth according to the transmission distance. Finally, the real-time EEG-based drowsiness monitoring and warning algorithms were implemented and integrated into the system to close the loop of the BCI system. The practical online testing demonstrates the feasibility of using the proposed system with the ability of real-time processing, automatic analysis, and online warning feedback in real-world operation and living environments.

  8. Design of electric control system for automatic vegetable bundling machine

    NASA Astrophysics Data System (ADS)

    Bao, Yan

    2017-06-01

    A design can meet the requirements of automatic bale food structure and has the advantages of simple circuit, and the volume is easy to enhance the electric control system of machine carrying bunch of dishes and low cost. The bundle of vegetable machine should meet the sensor to detect and control, in order to meet the control requirements; binding force can be adjusted by the button to achieve; strapping speed also can be adjusted, by the keys to set; sensors and mechanical line connection, convenient operation; can be directly connected with the plug, the 220V power supply can be connected to a power source; if, can work, by the transmission signal sensor, MCU to control the motor, drive and control procedures for small motor. The working principle of LED control circuit and temperature control circuit is described. The design of electric control system of automatic dish machine.

  9. Automatic Train Operation Using Autonomic Prediction of Train Runs

    NASA Astrophysics Data System (ADS)

    Asuka, Masashi; Kataoka, Kenji; Komaya, Kiyotoshi; Nishida, Syogo

    In this paper, we present an automatic train control method adaptable to disturbed train traffic conditions. The proposed method presumes transmission of detected time of a home track clearance to trains approaching to the station by employing equipment of Digital ATC (Automatic Train Control). Using the information, each train controls its acceleration by the method that consists of two approaches. First, by setting a designated restricted speed, the train controls its running time to arrive at the next station in accordance with predicted delay. Second, the train predicts the time at which it will reach the current braking pattern generated by Digital ATC, along with the time when the braking pattern transits ahead. By comparing them, the train correctly chooses the coasting drive mode in advance to avoid deceleration due to the current braking pattern. We evaluated the effectiveness of the proposed method regarding driving conditions, energy consumption and reduction of delays by simulation.

  10. Automated meter reading. (Latest citations from the INSPEC database). Published Search

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-12-01

    The bibliography contains citations concerning the automatic collection of data from utility meters. Citations focus on line carrier communications, radio communications, and telecommunication methods of data transmission. Applications for water, gas, and electric power meters are discussed. (Contains a minimum of 56 citations and includes a subject term index and title list.)

  11. Study and Test to Confirm Automobile Drivetrain Components to Improve Fuel Economy : Volume 2. The Drivetrain Design Process With an Automatic Transmission

    DOT National Transportation Integrated Search

    1979-05-01

    This report presents the key thought processes that are used by the drivetrain designer in matching an engine to a given vehicle with specific performance goals in mind. This report provides those uninitiated in this aspect of automotive design valua...

  12. Building and Operating Weather Satellite Ground Stations for High School Science. Teachers Guide.

    ERIC Educational Resources Information Center

    Summers, R. Joe; Gotwald, Timothy

    Automatic Picture Transmission (APT) images are real-time weather pictures transmitted from satellites on a radio frequency in a video format. Amateur radio enthusiasts and electronic experimenters have for a number of years designed, built, and operated direct readout stations capable of receiving APT photographs. The equipment to receive weather…

  13. 76 FR 66220 - Automatic Underfrequency Load Shedding and Load Shedding Plans Reliability Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-26

    ..., EPRI Power Systems Dynamics Tutorial, Chapter 4 at page 4-78 (2009), available at http://www.epri.com.... Power systems consist of static components (e.g., transformers and transmission lines) and dynamic... decisions on simulations, both static and dynamic, using area power system models to meet requirements in...

  14. Development and Testing of an Automatic Transmission Shift Schedule Algorithm for Vehicle Simulation (SAE Paper 2015-01-1142)

    EPA Science Inventory

    The Advanced Light-Duty Powertrain and Hybrid Analysis (ALPHA) modeling tool was created by EPA to estimate greenhouse gas (GHG) emissions of light-duty vehicles. ALPHA is a physics-based, forward-looking, full vehicle computer simulation capable of analyzing various vehicle type...

  15. Commercial applications

    NASA Technical Reports Server (NTRS)

    Togai, Masaki

    1990-01-01

    Viewgraphs on commercial applications of fuzzy logic in Japan are presented. Topics covered include: suitable application area of fuzzy theory; characteristics of fuzzy control; fuzzy closed-loop controller; Mitsubishi heavy air conditioner; predictive fuzzy control; the Sendai subway system; automatic transmission; fuzzy logic-based command system for antilock braking system; fuzzy feed-forward controller; and fuzzy auto-tuning system.

  16. Modulation-format-free and automatic bias control for optical IQ modulators based on dither-correlation detection.

    PubMed

    Li, Xiaolei; Deng, Lei; Chen, Xiaoman; Cheng, Mengfan; Fu, Songnian; Tang, Ming; Liu, Deming

    2017-04-17

    A novel automatic bias control (ABC) method for optical in-phase and quadrature (IQ) modulator is proposed and experimentally demonstrated. In the proposed method, two different low frequency sine wave dither signals are generated and added on to the I/Q bias signal respectively. Instead of power monitoring of the harmonics of the dither signal, dither-correlation detection is proposed and used to adjust the bias voltages of the optical IQ modulator. By this way, not only frequency spectral analysis isn't required but also the directional bias adjustment could be realized, resulting in the decrease of algorithm complexity and the growth of convergence rate of ABC algorithm. The results show that the sensitivity of the proposed ABC method outperforms that of the traditional dither frequency monitoring method. Moreover, the proposed ABC method is proved to be modulation-format-free, and the transmission penalty caused by this method for both 10 Gb/s optical QPSK and 17.9 Gb/s optical 16QAM-OFDM signal transmission are negligible in our experiment.

  17. Virus Particle Detection by Convolutional Neural Network in Transmission Electron Microscopy Images.

    PubMed

    Ito, Eisuke; Sato, Takaaki; Sano, Daisuke; Utagawa, Etsuko; Kato, Tsuyoshi

    2018-06-01

    A new computational method for the detection of virus particles in transmission electron microscopy (TEM) images is presented. Our approach is to use a convolutional neural network that transforms a TEM image to a probabilistic map that indicates where virus particles exist in the image. Our proposed approach automatically and simultaneously learns both discriminative features and classifier for virus particle detection by machine learning, in contrast to existing methods that are based on handcrafted features that yield many false positives and require several postprocessing steps. The detection performance of the proposed method was assessed against a dataset of TEM images containing feline calicivirus particles and compared with several existing detection methods, and the state-of-the-art performance of the developed method for detecting virus was demonstrated. Since our method is based on supervised learning that requires both the input images and their corresponding annotations, it is basically used for detection of already-known viruses. However, the method is highly flexible, and the convolutional networks can adapt themselves to any virus particles by learning automatically from an annotated dataset.

  18. Impulsive response of an automatic transmission system with multiple clearances: Formulation, simulation and experiment

    NASA Astrophysics Data System (ADS)

    Crowther, Ashley R.; Singh, Rajendra; Zhang, Nong; Chapman, Chris

    2007-10-01

    Impulsive responses in geared systems with multiple clearances are studied when the mean torque excitation and system load change abruptly, with application to a vehicle driveline with an automatic transmission. First, torsional lumped-mass models of the planetary and differential gear sets are formulated using matrix elements. The model is then reduced to address tractable nonlinear problems while successfully retaining the main modes of interest. Second, numerical simulations for the nonlinear model are performed for transient conditions and a typical driving situation that induces an impulsive behaviour simulated. However, initial conditions and excitation and load profiles have to be carefully defined before the model can be numerically solved. It is shown that the impacts within the planetary or differential gears may occur under combinations of engine, braking and vehicle load transients. Our analysis shows that the shaping of the engine transient by the torque converter before reaching the clearance locations is more critical. Third, a free vibration experiment is developed for an analogous driveline with multiple clearances and three experiments that excite different response regimes have been carried out. Good correlations validate the proposed methodology.

  19. Fractured-aquifer hydrogeology from geophysical logs: Brunswick group and Lockatong Formation, Pennsylvania

    USGS Publications Warehouse

    Morin, Roger H.; Senior, Lisa A.; Decker, Edward R.

    2000-01-01

    The Brunswick Group and the underlying Lockatong Formation are composed of lithified Mesozoic sediments that constitute part of the Newark Basin in southeastern Pennsylvania. These fractured rocks form an important regional aquifer that consists of gradational sequences of shale, siltstone, and sandstone, with fluid transport occurring primarily in fractures. An extensive suite of geophysical logs was obtained in seven wells located at the borough of Lansdale, Pennsylvania, in order to better characterize the areal hydrogeologic system and provide guidelines for the refinement of numerical ground water models. Six of the seven wells are approximately 120 m deep and the seventh extends to a depth of 335 m. Temperature, fluid conductivity, and flowmeter logs are used to locate zones of fluid exchange and to quantify transmissivities. Electrical resistivity and natural gamma logs together yield detailed stratigraphic information, and digital acoustic televiewer data provide magnetically oriented images of the borehole wall from which almost 900 fractures are identified.Analyses of the geophysical data indicate that the aquifer penetrated by the deep well can be separated into two distinct structural domains, which may, in turn, reflect different mechanical responses to basin extension by different sedimentary units:1. In the shallow zone (above 125 m), the dominant fracture population consists of gently dipping bedding plane partings that strike N46°E and dip to the northwest at about 11 degrees. Fluid flow is concentrated in the upper 80 m along these subhorizontal fractures, with transmissivities rapidly diminishing in magnitude with depth.2. The zone below 125 m marks the appearance of numerous high-angle fractures that are orthogonal to the bedding planes, striking parallel but dipping steeply southeast at 77 degrees.This secondary set of fractures is associated with a fairly thick (approximately 60 m) high-resistivity, low-transmissivity sandstone unit that is abruptly terminated by a thin shale bed at a depth of 190 m. This lower contact effectively delineates the aquifer's vertical extent at this location because no detectable evidence of ground water movement is found below it. Thus, fluid flow is controlled by fractures, but fracture type and orientation are related to lithology. Finally, a transient thermal-conduction model is successfully applied to simulate observed temperature logs, thereby confirming the effects of ground-surface warming that occurred in the area as a result of urbanization at the turn of the century. The systematic warming of the upper 120 m has increased the transmissivity of this aquifer by almost 10%, simply due to changes in fluid viscosity and density.

  20. Automatic Adaptation to Fast Input Changes in a Time-Invariant Neural Circuit

    PubMed Central

    Bharioke, Arjun; Chklovskii, Dmitri B.

    2015-01-01

    Neurons must faithfully encode signals that can vary over many orders of magnitude despite having only limited dynamic ranges. For a correlated signal, this dynamic range constraint can be relieved by subtracting away components of the signal that can be predicted from the past, a strategy known as predictive coding, that relies on learning the input statistics. However, the statistics of input natural signals can also vary over very short time scales e.g., following saccades across a visual scene. To maintain a reduced transmission cost to signals with rapidly varying statistics, neuronal circuits implementing predictive coding must also rapidly adapt their properties. Experimentally, in different sensory modalities, sensory neurons have shown such adaptations within 100 ms of an input change. Here, we show first that linear neurons connected in a feedback inhibitory circuit can implement predictive coding. We then show that adding a rectification nonlinearity to such a feedback inhibitory circuit allows it to automatically adapt and approximate the performance of an optimal linear predictive coding network, over a wide range of inputs, while keeping its underlying temporal and synaptic properties unchanged. We demonstrate that the resulting changes to the linearized temporal filters of this nonlinear network match the fast adaptations observed experimentally in different sensory modalities, in different vertebrate species. Therefore, the nonlinear feedback inhibitory network can provide automatic adaptation to fast varying signals, maintaining the dynamic range necessary for accurate neuronal transmission of natural inputs. PMID:26247884

  1. Non-destructive evaluation means and method of flaw reconstruction utilizing an ultrasonic multi-viewing transducer data acquistion system

    DOEpatents

    Thompson, Donald O.; Wormley, Samuel J.

    1989-03-28

    A multi-viewing ultrasound transducer acquisition system for non-destructive evaluation, flaw detection and flaw reconstruction in materials. A multiple transducer assembly includes a central transducer surrounded by a plurality of perimeter transducers, each perimeter transducer having an axis of transmission which can be angularly oriented with respect to the axis of transmission of the central transducer to intersect the axis of transmission of the central transducer. A control apparatus automatically and remotely positions the transducer assembly with respect to the material by a positioning apparatus and adjusts the pe GRANT REFERENCE This invention was conceived and reduced to practice at least in part under a grant from the Department of Energy under Contract No. W-7407-ENG-82.

  2. A Cost Effective Block Framing Scheme for Underwater Communication

    PubMed Central

    Shin, Soo-Young; Park, Soo-Hyun

    2011-01-01

    In this paper, the Selective Multiple Acknowledgement (SMA) method, based on Multiple Acknowledgement (MA), is proposed to efficiently reduce the amount of data transmission by redesigning the transmission frame structure and taking into consideration underwater transmission characteristics. The method is suited to integrated underwater system models, as the proposed method can handle the same amount of data in a much more compact frame structure without any appreciable loss of reliability. Herein, the performance of the proposed SMA method was analyzed and compared to those of the conventional Automatic Repeat-reQuest (ARQ), Block Acknowledgement (BA), block response, and MA methods. The efficiency of the underwater sensor network, which forms a large cluster and mostly contains uplink data, is expected to be improved by the proposed method. PMID:22247689

  3. Presence and Persistence of Ebola or Marburg Virus in Patients and Survivors: A Rapid Systematic Review.

    PubMed

    Brainard, Julii; Pond, Katherine; Hooper, Lee; Edmunds, Kelly; Hunter, Paul

    2016-02-01

    The 2013-15 Ebola outbreak was unprecedented due to sustained transmission within urban environments and thousands of survivors. In 2014 the World Health Organization stated that there was insufficient evidence to give definitive guidance about which body fluids are infectious and when they pose a risk to humans. We report a rapid systematic review of published evidence on the presence of filoviruses in body fluids of infected people and survivors. Scientific articles were screened for information about filovirus in human body fluids. The aim was to find primary data that suggested high likelihood of actively infectious filovirus in human body fluids (viral RNA). Eligible infections were from Marburg virus (MARV or RAVV) and Zaire, Sudan, Taï Forest and Bundibugyo species of Ebola. Cause of infection had to be laboratory confirmed (in practice either tissue culture or RT-PCR tests), or evidenced by compatible clinical history with subsequent positivity for filovirus antibodies or inflammatory factors. Data were extracted and summarized narratively. 6831 unique articles were found, and after screening, 33 studies were eligible. For most body fluid types there were insufficient patients to draw strong conclusions, and prevalence of positivity was highly variable. Body fluids taken >16 days after onset were usually negative. In the six studies that used both assay methods RT-PCR tests for filovirus RNA gave positive results about 4 times more often than tissue culture. Filovirus was reported in most types of body fluid, but not in every sample from every otherwise confirmed patient. Apart from semen, most non-blood, RT-PCR positive samples are likely to be culture negative and so possibly of low infectious risk. Nevertheless, it is not apparent how relatively infectious many body fluids are during or after illness, even when culture-positive, not least because most test results come from more severe cases. Contact with blood and blood-stained body fluids remains the major risk for disease transmission because of the known high viral loads in blood.

  4. Analysis on electronic control unit of continuously variable transmission

    NASA Astrophysics Data System (ADS)

    Cao, Shuanggui

    Continuously variable transmission system can ensure that the engine work along the line of best fuel economy, improve fuel economy, save fuel and reduce harmful gas emissions. At the same time, continuously variable transmission allows the vehicle speed is more smooth and improves the ride comfort. Although the CVT technology has made great development, but there are many shortcomings in the CVT. The CVT system of ordinary vehicles now is still low efficiency, poor starting performance, low transmission power, and is not ideal controlling, high cost and other issues. Therefore, many scholars began to study some new type of continuously variable transmission. The transmission system with electronic systems control can achieve automatic control of power transmission, give full play to the characteristics of the engine to achieve optimal control of powertrain, so the vehicle is always traveling around the best condition. Electronic control unit is composed of the core processor, input and output circuit module and other auxiliary circuit module. Input module collects and process many signals sent by sensor and , such as throttle angle, brake signals, engine speed signal, speed signal of input and output shaft of transmission, manual shift signals, mode selection signals, gear position signal and the speed ratio signal, so as to provide its corresponding processing for the controller core.

  5. Cost analysis of an electricity supply chain using modification of price based dynamic economic dispatch in wheeling transaction scheme

    NASA Astrophysics Data System (ADS)

    Wahyuda; Santosa, Budi; Rusdiansyah, Ahmad

    2018-04-01

    Deregulation of the electricity market requires coordination between parties to synchronize the optimization on the production side (power station) and the transport side (transmission). Electricity supply chain presented in this article is designed to facilitate the coordination between the parties. Generally, the production side is optimized with price based dynamic economic dispatch (PBDED) model, while the transmission side is optimized with Multi-echelon distribution model. Both sides optimization are done separately. This article proposes a joint model of PBDED and multi-echelon distribution for the combined optimization of production and transmission. This combined optimization is important because changes in electricity demand on the customer side will cause changes to the production side that automatically also alter the transmission path. The transmission will cause two cost components. First, the cost of losses. Second, the cost of using the transmission network (wheeling transaction). Costs due to losses are calculated based on ohmic losses, while the cost of using transmission lines using the MW - mile method. As a result, this method is able to provide best allocation analysis for electrical transactions, as well as emission levels in power generation and cost analysis. As for the calculation of transmission costs, the Reverse MW-mile method produces a cheaper cost than the Absolute MW-mile method

  6. The Presence and Anti-HIV-1 Function of Tenascin C in Breast Milk and Genital Fluids

    PubMed Central

    Jaeger, Frederick; McGuire, Erin; Fouda, Genevieve; Amos, Joshua; Barbas, Kimberly; Ohashi, Tomoo; Alam, S. Munir; Erickson, Harold; Permar, Sallie R.

    2016-01-01

    Tenascin-C (TNC) is a newly identified innate HIV-1-neutralizing protein present in breast milk, yet its presence and potential HIV-inhibitory function in other mucosal fluids is unknown. In this study, we identified TNC as a component of semen and cervical fluid of HIV-1-infected and uninfected individuals, although it is present at a significantly lower concentration and frequency compared to that of colostrum and mature breast milk, potentially due to genital fluid protease degradation. However, TNC was able to neutralize HIV-1 after exposure to low pH, suggesting that TNC could be active at low pH in the vaginal compartment. As mucosal fluids are complex and contain a number of proteins known to interact with the HIV-1 envelope, we further studied the relationship between the concentration of TNC and neutralizing activity in breast milk. The amount of TNC correlated only weakly with the overall innate HIV-1-neutralizing activity of breast milk of uninfected women and negatively correlated with neutralizing activity in milk of HIV-1 infected women, indicating that the amount of TNC in mucosal fluids is not adequate to impede HIV-1 transmission. Moreover, the presence of polyclonal IgG from milk of HIV-1 infected women, but not other HIV-1 envelope-binding milk proteins or monoclonal antibodies, blocked the neutralizing activity of TNC. Finally, as exogenous administration of TNC would be necessary for it to mediate measurable HIV-1 neutralizing activity in mucosal compartments, we established that recombinantly produced TNC has neutralizing activity against transmitted/founder HIV-1 strains that mimic that of purified TNC. Thus, we conclude that endogenous TNC concentration in mucosal fluids is likely inadequate to block HIV-1 transmission to uninfected individuals. PMID:27182834

  7. SU-G-TeP4-07: Automatic EPID-Based 2D Measurement of MLC Leaf Offset as a Quality Control Tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ritter, T; Moran, J; Schultz, B

    Purpose: The MLC dosimetric leaf gap (DLG) and transmission are measured parameters which impact the dosimetric accuracy of IMRT and VMAT plans. This investigation aims to develop an efficient and accurate routine constancy check of the physical DLG in two dimensions. Methods: The manufacturer’s recommended DLG measurement method was modified by using 5 fields instead of 11 and by utilizing the Electronic Portal Imaging Device (EPID). Validations were accomplished using an ion chamber (IC) in solid water and a 2D IC array. EPID data was collected for 6 months on multiple TrueBeam linacs using both Millennium and HD MLCs atmore » 5 different clinics in an international consortium. Matlab code was written to automatically analyze the images and calculate the 2D results. Sensitivity was investigated by introducing deliberate leaf position errors. MLC calibration and initialization history was recorded to allow quantification of their impact. Results were analyzed using statistical process control (SPC). Results: The EPID method took approximately 5 minutes. Due to detector response, the EPID measured DLG and transmission differed from the IC values but were reproducible and consistent with changes measured using the ICs. For the Millennium MLC, the EPID measured DLG and transmission were both consistently lower than IC results. The EPID method was implemented as leaf offset and transmission constancy tests (LOC and TC). Based on 6 months of measurements, the initial leaf-specific action thresholds for changes from baseline were set to 0.1 mm. Upper and lower control limits for variation were developed for each machine. Conclusion: Leaf offset and transmission constancy tests were implemented on Varian HD and Millennium MLCs using an EPID and found to be efficient and accurate. The test is effective for monitoring MLC performance using dynamic delivery and performing process control on the DLG in 2D, thus enhancing dosimetric accuracy. This work was supported by a grant from Varian Medical Systems.« less

  8. The ECLSS Advanced Automation Project Evolution and Technology Assessment

    NASA Technical Reports Server (NTRS)

    Dewberry, Brandon S.; Carnes, James R.; Lukefahr, Brenda D.; Rogers, John S.; Rochowiak, Daniel M.; Mckee, James W.; Benson, Brian L.

    1990-01-01

    Viewgraphs on Environmental Control and Life Support System (ECLSS) advanced automation project evolution and technology assessment are presented. Topics covered include: the ECLSS advanced automation project; automatic fault diagnosis of ECLSS subsystems descriptions; in-line, real-time chemical and microbial fluid analysis; and object-oriented, distributed chemical and microbial modeling of regenerative environmental control systems description.

  9. Slim hole drilling and testing strategies

    NASA Astrophysics Data System (ADS)

    Nielson, Dennis L.; Garg, Sabodh K.; Goranson, Colin

    2017-12-01

    The financial and geologic advantages of drilling slim holes instead of large production wells in the early stages of geothermal reservoir assessment has been understood for many years. However, the practice has not been fully embraced by geothermal developers. We believe that the reason for this is that there is a poor understanding of testing and reservoir analysis that can be conducted in slim holes. In addition to reservoir engineering information, coring through the cap rock and into the reservoir provides important data for designing subsequent production well drilling and completion. Core drilling requires significantly less mud volume than conventional rotary drilling, and it is typically not necessary to cure lost circulation zones (LCZ). LCZs should be tested by either production or injection methods as they are encountered. The testing methodologies are similar to those conducted on large-diameter wells; although produced and/or injected fluid volumes are much less. Pressure, temperature and spinner (PTS) surveys in slim holes under static conditions can used to characterize temperature and pressure distribution in the geothermal reservoir. In many cases it is possible to discharge slim holes and obtain fluid samples to delineate the geochemical properties of the reservoir fluid. Also in the latter case, drawdown and buildup data obtained using a downhole pressure tool can be employed to determine formation transmissivity and well properties. Even if it proves difficult to discharge a slim hole, an injection test can be performed to obtain formation transmissivity. Given the discharge (or injection) data from a slimhole, discharge properties of a large-diameter well can be inferred using wellbore modeling. Finally, slim hole data (pressure, temperature, transmissivity, fluid properties) together with reservoir simulation can help predict the ability of the geothermal reservoir to sustain power production.

  10. Techniques for Developing an Acquisition Strategy by Profiling Software Risks

    DTIC Science & Technology

    2006-08-01

    Drivers...................................................................................... 13 Figure 8: BMW 745Li Software... BMW 745Li, shown in Figure 8, is a good illustration of the increasing software control of hardware systems in automobiles. Among the many features...roll stabilization, dynamic brake con- trol, coded drive-away protection, an adaptive automatic transmission, and iDrive systems. This list can be

  11. Design of a modular digital computer system, DRL 4. [for meeting future requirements of spaceborne computers

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The design is reported of an advanced modular computer system designated the Automatically Reconfigurable Modular Multiprocessor System, which anticipates requirements for higher computing capacity and reliability for future spaceborne computers. Subjects discussed include: an overview of the architecture, mission analysis, synchronous and nonsynchronous scheduling control, reliability, and data transmission.

  12. Automotive Power Flow System; Auto Mechanics I: 9043.04.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    This automotive power flow system course sets the foundation in the theory of operation of the standard and automatic transmission, clutch assemblies, drive-line and rear axle assemblies. This is a one or two quinmester credit course covering 45 clock hours. In the fourth quinmester course in the tenth year, instruction consists of lectures,…

  13. The FLOWS (FAA-Lincoln Laboratory Operational Weather Studies) Automatic Weather Station Network in Operation.

    DTIC Science & Technology

    1987-03-26

    20o, there is little change in observed transmission with further increases in angle. A similar result, obtained by Naegeli (1953) for the small end...Reclamation, June (1983). MacCready, P.J., "Mean Wind Speed Measurements in Turbulence", J. Appl. Meteor., 5, pp. 219-225 (1966). Naegeli , W

  14. A judging principle of crucial vibrational transmission paths in plates

    NASA Astrophysics Data System (ADS)

    Wang, Bin; Li, Dong-Xu; Jiang, Jian-Ping; Liao, Yi-Huan

    2016-10-01

    This paper developed a judging principle of crucial vibrational transmission path (VTP) in plates. Novel generalized definitions of VTPs are given referred to the meaning of streamlines. And by comparing governing equations, the similarity between energy flow and fluid motion is firstly found so that an analytic method of VTPs in plates is proposed by analogy with fluid motion. Hereafter, the crucial VTP is defined for energy flows at objective points and relative judging criteria is given. Finally, based on two numerical experiments of passive control, the judging principle is indirectly verified by comparing the reduction effects of energy flows at focused points and relative judgment results of crucial VTPs. This paper is meaningful for analyzing and applying the VTPs in plates to guide the control design in future.

  15. Automatic quality assessment of planetary images

    NASA Astrophysics Data System (ADS)

    Sidiropoulos, P.; Muller, J.-P.

    2015-10-01

    A significant fraction of planetary images are corrupted beyond the point that much scientific meaning can be extracted. For example, transmission errors result in missing data which is unrecoverable. The available planetary image datasets include many such "bad data", which both occupy valuable scientific storage resources and create false impressions about planetary image availability for specific planetary objects or target areas. In this work, we demonstrate a pipeline that we have developed to automatically assess the quality of planetary images. Additionally, this method discriminates between different types of image degradation, such as low-quality originating from camera flaws or low-quality triggered by atmospheric conditions, etc. Examples of quality assessment results for Viking Orbiter imagery will be also presented.

  16. Knowledge acquisition to qualify Unified Medical Language System interconceptual relationships.

    PubMed Central

    Le Duff, F.; Burgun, A.; Cleret, M.; Pouliquen, B.; Barac'h, V.; Le Beux, P.

    2000-01-01

    Adding automatically relations between concepts from a database to a knowledge base such as the Unified Medical Language System can be very useful to increase the consistency of the latter one. But the transfer of qualified relationships is more interesting. The most important interest of these new acquisitions is that the UMLS became more compliant and medically pertinent to be used in different medical applications. This paper describes the possibility to inherit automatically medical inter-conceptual relationships qualifiers from a disease description included into a database and to integrate them into the UMLS knowledge base. The paper focuses on the transmission of knowledge from a French medical database to an English one. PMID:11079930

  17. Development of an Automatic Detection Program of Halo CMEs

    NASA Astrophysics Data System (ADS)

    Choi, K.; Park, M. Y.; Kim, J.

    2017-12-01

    The front-side halo CMEs are the major cause for large geomagnetic storms. Halo CMEs can result in damage to satellites, communication, electrical transmission lines and power systems. Thus automated techniques for detecting and analysing Halo CMEs from coronagraph data are of ever increasing importance for space weather monitoring and forecasting. In this study, we developed the algorithm that can automatically detect and do image processing the Halo CMEs in the images from the LASCO C3 coronagraph on board the SOHO spacecraft. With the detection algorithm, we derived the geometric and kinematical parameters of halo CMEs, such as source location, width, actual CME speed and arrival time at 21.5 solar radii.

  18. Advanced statistical analysis of Raman spectroscopic data for the identification of body fluid traces: semen and blood mixtures.

    PubMed

    Sikirzhytski, Vitali; Sikirzhytskaya, Aliaksandra; Lednev, Igor K

    2012-10-10

    Conventional confirmatory biochemical tests used in the forensic analysis of body fluid traces found at a crime scene are destructive and not universal. Recently, we reported on the application of near-infrared (NIR) Raman microspectroscopy for non-destructive confirmatory identification of pure blood, saliva, semen, vaginal fluid and sweat. Here we expand the method to include dry mixtures of semen and blood. A classification algorithm was developed for differentiating pure body fluids and their mixtures. The classification methodology is based on an effective combination of Support Vector Machine (SVM) regression (data selection) and SVM Discriminant Analysis of preprocessed experimental Raman spectra collected using an automatic mapping of the sample. This extensive cross-validation of the obtained results demonstrated that the detection limit of the minor contributor is as low as a few percent. The developed methodology can be further expanded to any binary mixture of complex solutions, including but not limited to mixtures of other body fluids. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Modal sound transmission loss of a single leaf panel: Effects of inter-modal coupling.

    PubMed

    Wang, Chong

    2015-06-01

    Sound transmission through a single leaf panel has mostly been discussed and explained by using the approaching wave concept, from which the well-known mass law can be derived. In this paper, the modal behavior in sound transmission coefficients is explored, and it is shown that the mutual modal radiation impedances in modal sound transmission coefficients may not be ignored even for a panel immersed in a light fluid. By introducing the equivalent modal impedance which incorporates the inter-modal coupling effect, an analytical expression for the modal sound transmission coefficient is derived, and the overall sound transmission coefficient is simply a modal superposition of modal sound transmission coefficients. A good correlation is obtained between analytical calculation and boundary element method. In addition, it is found that inter-modal coupling has noticeable effects in modal sound transmission coefficients in the subsonic region but may be ignored as modes become supersonic. It is also shown that the well-known mass law performance is attributed to all the supersonic modes.

  20. Ebola Virus and Marburg Virus

    MedlinePlus

    ... chimps and fruit bats in Africa. Transmission from animals to humans Experts suspect that both viruses are transmitted to humans through an infected animal's bodily fluids. Examples include: Blood. Butchering or eating ...

  1. GSE, data management system programmers/User' manual

    NASA Technical Reports Server (NTRS)

    Schlagheck, R. A.; Dolerhie, B. D., Jr.; Ghiglieri, F. J.

    1974-01-01

    The GSE data management system is a computerized program which provides for a central storage source for key data associated with the mechanical ground support equipment (MGSE). Eight major sort modes can be requested by the user. Attributes that are printed automatically with each sort include the GSE end item number, description, class code, functional code, fluid media, use location, design responsibility, weight, cost, quantity, dimensions, and applicable documents. Multiple subsorts are available for the class code, functional code, fluid media, use location, design responsibility, and applicable document categories. These sorts and how to use them are described. The program and GSE data bank may be easily updated and expanded.

  2. Shielded, Automated Umbilical Mechanism

    NASA Technical Reports Server (NTRS)

    Barron, Daniel R.; Morrill, Brion F.; Jasulaitis, Vytas

    1995-01-01

    Umbilical mechanism automatically connects and disconnects various fluid couplings and/or electrical contacts while shielding mating parts from debris. Reacts mating and demating loads internally, without additional supporting structures. All functions - extension of plug, mating, and movement of debris shields - actuated by single motor. If mechanism jams or fails at any point in sequence, override feature in drive train allows manual operation. Designed for service in outer space, where its shields protect against micrometeoroids, debris, ultraviolet radiation, and atomic oxygen. Used on Earth to connect or disconnect fluid or electrical utilities in harsh environments like those of nuclear powerplants or undersea construction sites, or in presence of radioactive, chemical, or biological hazards, for example.

  3. Resource Manual for Handling Body Fluids in the School Setting To Prevent the Transmission of Human Immunodeficiency Virus and Hepatitis B Virus.

    ERIC Educational Resources Information Center

    Maryland State Dept. of Health and Mental Hygiene, Baltimore.

    Guidelines to prevent the transmission of blood-borne diseases, especially those caused by the Human Immunodeficiency Virus (HIV) and the Hepatitis B Virus (HBV), in the school setting are provided in this resource manual for school staff. Sections include information on the reasons for the development of this manual; a summary of the means of HIV…

  4. Effects of End CAP and Aspect Ratio on Transmission of Sound across a Truss-Like Periodic Double Panel

    NASA Astrophysics Data System (ADS)

    EL-RAHEB, M.; WAGNER, P.

    2002-02-01

    Transmission of sound across 2-D truss-like periodic double panels separated by an air gap and in contact with an acoustic fluid on the external faces is analyzed. Each panel is made of repeated cells. Combining the transfer matrices of the unit cell forms a set of equations for the overall elastic frequency response. The acoustic pressure in the fluids is expressed using a source boundary element method. Adding rigid reflecting end caps confines the air in the gap between panels which influences sound transmission. Measured values of transmission loss differ from the 2-D model by the wide low-frequency dip of the mass-spring-mass or “msm” resonance also termed the “air gap resonance”. In this case, the panels act as rigid masses and the air gap acts as an adiabatic air spring. Results from the idealized 3-D and 2-D models, incorporating rigid cavities and elastic plates, reveal that the “msm” dip is absent in 2-D models radiating into a semi-infinite medium. The dip strengthens as aspect ratio approaches unity. Even when the dip disappears in 2-D, TL rises more steeply for frequencies above the “msm” frequency.

  5. Donor-to-host transmission of bacterial and fungal infections in lung transplantation.

    PubMed

    Ruiz, I; Gavaldà, J; Monforte, V; Len, O; Román, A; Bravo, C; Ferrer, A; Tenorio, L; Román, F; Maestre, J; Molina, I; Morell, F; Pahissa, A

    2006-01-01

    The purpose of this study was to evaluate the incidence and etiology of bacterial and fungal infection or contamination in lung allograft donors and to assess donor-to-host transmission of these infections. Recipients who survived more than 24 h and their respective donors were evaluated. The overall incidence of donor infection was 52% (103 out of 197 donors). Types of donor infection included isolated contamination of preservation fluids (n = 30, 29.1%), graft colonization (n = 65, 63.1%) and bacteremia (n = 8, 7.8%). Donor-to-host transmission of bacterial or fungal infection occurred in 15 lung allograft recipients, 7.6% of lung transplants performed. Among these cases, 2 were due to donor bacteremia and 13 to colonization of the graft. Twenty-five percent of donors with bacteremia and 14.1% of colonized grafts were responsible for transmitting infection. Excluding the five cases without an effective prophylactic regimen, prophylaxis failure occurred in 11 out of 197 procedures (5.58%). Donor-to-host transmission of infection is a frequent event after lung transplantation. Fatal consequences can be avoided with an appropriate prophylactic antibiotic regimen that must be modified according to the microorganisms isolated from cultures of samples obtained from donors, grafts, preservation fluids and recipients.

  6. Orientation and phase mapping in the transmission electron microscope using precession-assisted diffraction spot recognition: state-of-the-art results.

    PubMed

    Viladot, D; Véron, M; Gemmi, M; Peiró, F; Portillo, J; Estradé, S; Mendoza, J; Llorca-Isern, N; Nicolopoulos, S

    2013-10-01

    A recently developed technique based on the transmission electron microscope, which makes use of electron beam precession together with spot diffraction pattern recognition now offers the possibility to acquire reliable orientation/phase maps with a spatial resolution down to 2 nm on a field emission gun transmission electron microscope. The technique may be described as precession-assisted crystal orientation mapping in the transmission electron microscope, precession-assisted crystal orientation mapping technique-transmission electron microscope, also known by its product name, ASTAR, and consists in scanning the precessed electron beam in nanoprobe mode over the specimen area, thus producing a collection of precession electron diffraction spot patterns, to be thereafter indexed automatically through template matching. We present a review on several application examples relative to the characterization of microstructure/microtexture of nanocrystalline metals, ceramics, nanoparticles, minerals and organics. The strengths and limitations of the technique are also discussed using several application examples. ©2013 The Authors. Journal of Microscopy published by John Wiley & Sons Ltd on behalf of Royal Microscopical Society.

  7. A heterogeneous computing environment for simulating astrophysical fluid flows

    NASA Technical Reports Server (NTRS)

    Cazes, J.

    1994-01-01

    In the Concurrent Computing Laboratory in the Department of Physics and Astronomy at Louisiana State University we have constructed a heterogeneous computing environment that permits us to routinely simulate complicated three-dimensional fluid flows and to readily visualize the results of each simulation via three-dimensional animation sequences. An 8192-node MasPar MP-1 computer with 0.5 GBytes of RAM provides 250 MFlops of execution speed for our fluid flow simulations. Utilizing the parallel virtual machine (PVM) language, at periodic intervals data is automatically transferred from the MP-1 to a cluster of workstations where individual three-dimensional images are rendered for inclusion in a single animation sequence. Work is underway to replace executions on the MP-1 with simulations performed on the 512-node CM-5 at NCSA and to simultaneously gain access to more potent volume rendering workstations.

  8. Developments in the design, analysis, and fabrication of advanced technology transmission elements

    NASA Technical Reports Server (NTRS)

    Drago, R. J.; Lenski, J. W., Jr.

    1982-01-01

    Over the last decade, the presently reported proprietary development program for the reduction of helicopter drive system weight and cost and the enhancement of reliability and survivability has produced high speed roller bearings, resin-matrix composite rotor shafts and transmission housings, gear/bearing/shaft system integrations, photoelastic investigation methods for gear tooth strength, and the automatic generation of complex FEM models for gear/shaft systems. After describing the design features and performance capabilities of the hardware developed, attention is given to the prospective benefits to be derived from application of these technologies, with emphasis on the relationship between helicopter drive system performance and cost.

  9. Roughness-Dominated Hydraulic Fracture Propagation

    NASA Astrophysics Data System (ADS)

    Garagash, D.

    2015-12-01

    Current understanding suggests that the energy to propagate a hydraulic fracture is defined by the viscous fluid pressure drop along the fracture channel, while the energy dissipation in the immediate vicinity of the fracture front (i.e. fracture toughness) is negligible. This status quo relies on the assumption of Poiseuille flow in the fracture, which transmissivity varies as cube of the aperture. We re-evaluate this assumption in the vicinity of the fracture tip, where the aperture roughness and/or branching of the fracture path may lead to very significant deviations from the cubic law. Existing relationships suggest rough fracture transmissivity power laws ~ wr with 4.5 ≤ r ≤ 6, when aperture w is smaller than the roughness. Solving for the tip region of a steadily propagating hydraulic fracture with the "rough fracture" transmissivity, we are able to show (a) larger energy dissipation than predicted by the Poiseuille flow model; (b) localization of the fluid pressure drop into the low-transmissivity, rough tip region; and (c) emergence of potentially preeminent "toughness-dominated" fracture propagation regime where most of the energy is dissipated at the tip and can be described in the context of classical fracture mechanics by invoking the effective fracture toughness dependent upon the details of the pressure drop in the rough tip. We establish that the ratio of the roughness scale wc to the viscous aperture scale wμ = μVE / σ02, controls the pressure drop localization. (Here V - propagation speed, μ - fluid viscosity, E - rock modulus, and σ0 - in-situ stress). For a range of industrial fracturing fluids (from slick-water to linear gels) and treatment conditions, wc/wμ is large, suggesting a fully-localized pressure drop and energy dissipation. The latter is adequately described by the effective toughness - a function of the propagation velocity, confining stress and material parameters, which estimated values are much larger than the "dry" rock fracture toughness measured in the lab. Using the effective, velocity-dependent fracture toughness to predict the evolution of a penny-shape fracture, we are able to show how/when the classical viscosity-dominated and toughness-dominated solutions based upon the Poiseuille law and the "dry", laboratory fracture toughness values, respectively, may become inadequate.

  10. Coupling apparatus for ultrasonic medical diagnostic system

    NASA Technical Reports Server (NTRS)

    Frazer, R. E. (Inventor)

    1978-01-01

    An apparatus for the ultrasonic scanning of a breast or other tissue is reported that contains a cavity for receiving the breast, a vacuum for drawing the breast into intimate contact with the walls of the cavity, and transducers coupled through a fluid to the cavity to transmit sound waves through the breast. Each transducer lies at the end of a tapered chamber which has flexible walls and which is filled with fluid, so that the transducer can be moved in a raster pattern while the chamber walls flex accordingly, with sound transmission always occurring through the fluid.

  11. Automatic tissue image segmentation based on image processing and deep learning

    NASA Astrophysics Data System (ADS)

    Kong, Zhenglun; Luo, Junyi; Xu, Shengpu; Li, Ting

    2018-02-01

    Image segmentation plays an important role in multimodality imaging, especially in fusion structural images offered by CT, MRI with functional images collected by optical technologies or other novel imaging technologies. Plus, image segmentation also provides detailed structure description for quantitative visualization of treating light distribution in the human body when incorporated with 3D light transport simulation method. Here we used image enhancement, operators, and morphometry methods to extract the accurate contours of different tissues such as skull, cerebrospinal fluid (CSF), grey matter (GM) and white matter (WM) on 5 fMRI head image datasets. Then we utilized convolutional neural network to realize automatic segmentation of images in a deep learning way. We also introduced parallel computing. Such approaches greatly reduced the processing time compared to manual and semi-automatic segmentation and is of great importance in improving speed and accuracy as more and more samples being learned. Our results can be used as a criteria when diagnosing diseases such as cerebral atrophy, which is caused by pathological changes in gray matter or white matter. We demonstrated the great potential of such image processing and deep leaning combined automatic tissue image segmentation in personalized medicine, especially in monitoring, and treatments.

  12. Self-actuating and locking control for nuclear reactor

    DOEpatents

    Chung, Dong K.

    1982-01-01

    A self-actuating, self-locking flow cutoff valve particularly suited for use in a nuclear reactor of the type which utilizes a plurality of fluid support neutron absorber elements to provide for the safe shutdown of the reactor. The valve comprises a substantially vertical elongated housing and an aperture plate located in the housing for the flow of fluid therethrough, a substantially vertical elongated nozzle member located in the housing and affixed to the housing with an opening in the bottom for receiving fluid and apertures adjacent a top end for discharging fluid. The nozzle further includes two sealing means, one located above and the other below the apertures. Also located in the housing and having walls surrounding the nozzle is a flow cutoff sleeve having a fluid opening adjacent an upper end of the sleeve, the sleeve being moveable between an upper open position wherein the nozzle apertures are substantially unobstructed and a closed position wherein the sleeve and nozzle sealing surfaces are mated such that the flow of fluid through the apertures is obstructed. It is a particular feature of the present invention that the valve further includes a means for utilizing any increase in fluid pressure to maintain the cutoff sleeve in a closed position. It is another feature of the invention that there is provided a means for automatically closing the valve whenever the flow of fluid drops below a predetermined level.

  13. Determination of Stability and Control Derivatives using Computational Fluid Dynamics and Automatic Differentiation

    NASA Technical Reports Server (NTRS)

    Park, Michael A.; Green, Lawrence L.; Montgomery, Raymond C.; Raney, David L.

    1999-01-01

    With the recent interest in novel control effectors there is a need to determine the stability and control derivatives of new aircraft configurations early in the design process. These derivatives are central to most control law design methods and would allow the determination of closed-loop control performance of the vehicle. Early determination of the static and dynamic behavior of an aircraft may permit significant improvement in configuration weight, cost, stealth, and performance through multidisciplinary design. The classical method of determining static stability and control derivatives - constructing and testing wind tunnel models - is expensive and requires a long lead time for the resultant data. Wind tunnel tests are also limited to the preselected control effectors of the model. To overcome these shortcomings, computational fluid dynamics (CFD) solvers are augmented via automatic differentiation, to directly calculate the stability and control derivatives. The CFD forces and moments are differentiated with respect to angle of attack, angle of sideslip, and aircraft shape parameters to form these derivatives. A subset of static stability and control derivatives of a tailless aircraft concept have been computed by two differentiated inviscid CFD codes and verified for accuracy with central finite-difference approximations and favorable comparisons to a simulation database.

  14. Intelligent automated surface grid generation

    NASA Technical Reports Server (NTRS)

    Yao, Ke-Thia; Gelsey, Andrew

    1995-01-01

    The goal of our research is to produce a flexible, general grid generator for automated use by other programs, such as numerical optimizers. The current trend in the gridding field is toward interactive gridding. Interactive gridding more readily taps into the spatial reasoning abilities of the human user through the use of a graphical interface with a mouse. However, a sometimes fruitful approach to generating new designs is to apply an optimizer with shape modification operators to improve an initial design. In order for this approach to be useful, the optimizer must be able to automatically grid and evaluate the candidate designs. This paper describes and intelligent gridder that is capable of analyzing the topology of the spatial domain and predicting approximate physical behaviors based on the geometry of the spatial domain to automatically generate grids for computational fluid dynamics simulators. Typically gridding programs are given a partitioning of the spatial domain to assist the gridder. Our gridder is capable of performing this partitioning. This enables the gridder to automatically grid spatial domains of wide range of configurations.

  15. Design and Fabrication of Automatic Glass Cutting Machine

    NASA Astrophysics Data System (ADS)

    Veena, T. R.; Kadadevaramath, R. S.; Nagaraj, P. M.; Madhusudhan, S. V.

    2016-09-01

    This paper deals with the design and fabrication of the automatic glass or mirror cutting machine. In order to increase the accuracy of cut and production rate; and decrease the production time and accidents caused due to manual cutting of mirror or glass, this project aims at development of an automatic machine which uses a programmable logic controller (PLC) for controlling the movement of the conveyer and also to control the pneumatic circuit. In this machine, the work of the operator is to load and unload the mirror. The cutter used in this machine is carbide wheel with its cutting edge ground to a V-shaped profile. The PLC controls the pneumatic cylinder and intern actuates the cutter along the glass, a fracture layer is formed causing a mark to be formed below the fracture layer and a crack to be formed below the rib mark. The machine elements are designed using CATIA V5R20 and pneumatic circuit are designed using FESTO FLUID SIM software.

  16. 75 FR 2557 - Interim Policy for the Sharing of Information Collected by the Coast Guard Nationwide Automatic...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-15

    ... (real-time) information collected by the NAIS that is less than 12 hours from transmission. Level B... specific questions on the development of the NAIS final policy: 1. How might providing real-time, near real... collected by the NAIS considered sensitive? a. Is real-time or near real-time information collected by the...

  17. Bandwidth controller for phase-locked-loop

    NASA Technical Reports Server (NTRS)

    Brockman, Milton H. (Inventor)

    1992-01-01

    A phase locked loop utilizing digital techniques to control the closed loop bandwidth of the RF carrier phase locked loop in a receiver provides high sensitivity and a wide dynamic range for signal reception. After analog to digital conversion, a digital phase locked loop bandwidth controller provides phase error detection with automatic RF carrier closed loop tracking bandwidth control to accommodate several modes of transmission.

  18. The Rules of the Game and the Uncertain Transmission of Advantage: Middle-Class Parents' Search for an Urban Kindergarten

    ERIC Educational Resources Information Center

    Lareau, Annette; Adia Evans, Shani; Yee, April

    2016-01-01

    Empirical research on cultural and social capital has generally ignored the key role of institutions in setting standards that determine the contingent value of this capital. Furthermore, many studies presume that the yielding of profit from cultural, social, and economic capital is automatic. Bourdieu's concept of field highlights the ''rules of…

  19. Asbestos Workshop: Sampling, Analysis, and Risk Assessment

    DTIC Science & Technology

    2012-03-01

    coatings Vinyl/asbestos floor tile Automatic transmission components Clutch facings Disc brake pads Drum brake linings Brake blocks Commercial and...A naturally-occurring pliant and fibrous mineral with heat-resistant properties • Serpentine Class: joint compound,‘popcorn’ceilings, brake pads...fabrics, and is used in fire-resistant and insulating materials such as brake linings. The asbestos minerals include chrysotile (white asbestos) and

  20. 49 CFR 571.122 - Standard No. 122; Motorcycle brake systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... transmission of signals in the motorcycle's ABS system. (b) To permit function checking, the warning lamp shall... CFR 571.101). S5.2Durability. S5.2.1Compensation for wear. Wear of the brakes shall be compensated for by means of a system of automatic or manual adjustment. S5.2.2Notice of wear. The friction material...

  1. 49 CFR 571.122 - Standard No. 122; Motorcycle brake systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... transmission of signals in the motorcycle's ABS system. (b) To permit function checking, the warning lamp shall... CFR 571.101). S5.2Durability. S5.2.1Compensation for wear. Wear of the brakes shall be compensated for by means of a system of automatic or manual adjustment. S5.2.2Notice of wear. The friction material...

  2. Automotive technology status and projections. Volume 2: Assessment report

    NASA Technical Reports Server (NTRS)

    Dowdy, M.; Burke, A.; Schneider, H.; Edmiston, W.; Klose, G. J.; Heft, R.

    1978-01-01

    Current and advanced conventional engines, advanced alternative engines, advanced power train components, and other energy conserving automobile modifications which could be implemented by the end of this century are examined. Topics covered include gas turbine engines, Stirling engines, advanced automatic transmissions, alternative fuels, and metal and ceramic technology. Critical problems are examined and areas for future research are indicated.

  3. 49 CFR 571.114 - Standard No. 114; Theft protection and rollaway prevention.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... pounds) or less with an automatic transmission that includes a “park” position shall be equipped with a... forward up a 10 percent grade and stop it with the service brakes. (b) Apply the parking brake (if present). (c) Move the gear selection control to “park.” (d) Note the vehicle position. (e) Release the parking...

  4. 49 CFR 571.114 - Standard No. 114; Theft protection and rollaway prevention.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... pounds) or less with an automatic transmission that includes a “park” position shall be equipped with a... forward up a 10 percent grade and stop it with the service brakes. (b) Apply the parking brake (if present). (c) Move the gear selection control to “park.” (d) Note the vehicle position. (e) Release the parking...

  5. Smartphone based automatic organ validation in ultrasound video.

    PubMed

    Vaish, Pallavi; Bharath, R; Rajalakshmi, P

    2017-07-01

    Telesonography involves transmission of ultrasound video from remote areas to the doctors for getting diagnosis. Due to the lack of trained sonographers in remote areas, the ultrasound videos scanned by these untrained persons do not contain the proper information that is required by a physician. As compared to standard methods for video transmission, mHealth driven systems need to be developed for transmitting valid medical videos. To overcome this problem, we are proposing an organ validation algorithm to evaluate the ultrasound video based on the content present. This will guide the semi skilled person to acquire the representative data from patient. Advancement in smartphone technology allows us to perform high medical image processing on smartphone. In this paper we have developed an Application (APP) for a smartphone which can automatically detect the valid frames (which consist of clear organ visibility) in an ultrasound video and ignores the invalid frames (which consist of no-organ visibility), and produces a compressed sized video. This is done by extracting the GIST features from the Region of Interest (ROI) of the frame and then classifying the frame using SVM classifier with quadratic kernel. The developed application resulted with the accuracy of 94.93% in classifying valid and invalid images.

  6. Fundamental study of subharmonic vibration of order 1/2 in automatic transmissions for cars

    NASA Astrophysics Data System (ADS)

    Ryu, T.; Nakae, T.; Matsuzaki, K.; Nanba, A.; Takikawa, Y.; Ooi, Y.; Sueoka, A.

    2016-09-01

    A torque converter is an element that transfers torque from the engine to the gear train in the automatic transmission of an automobile. The damper spring of the lock-up clutch in the torque converter is used to effectively absorb the torsional vibration caused by engine combustion. A damper with low stiffness reduces fluctuations in rotational speed but is difficult to use because of space limitations. In order to address this problem, the damper is designed using a piecewise-linear spring with three stiffness stages. However, the damper causes a nonlinear vibration referred to as a subharmonic vibration of order 1/2. In the subharmonic vibration, the frequency is half that of the vibrations from the engine. In order to clarify the mechanism of the subharmonic vibration, in the present study, experiments are conducted using the fundamental experimental apparatus of a single-degree-of-freedom system with two stiffness stages. In the experiments, countermeasures to reduce the subharmonic vibration by varying the conditions of the experiments are also performed. The results of the experiments are evaluated through numerical analysis using the shooting method. The experimental and analytical results were found to be in close agreement.

  7. Zika - Sexual Transmission and Prevention

    MedlinePlus

    ... Español (Spanish) Recommend on Facebook Tweet Share Compartir Zika Can Be Passed Through Sex Zika can be ... in other body fluids. Infected People Can Pass Zika Through Sex Even When They Don’t Have ...

  8. Automatic fixation facility for plant seedlings in the TEXUS Sounding Rocket Programme.

    PubMed

    Tewinkel, M; Burfeindt, J; Rank, P; Volkmann, D

    1991-10-01

    Automatic chemical fixation of plant seedlings within a 6 min period of reduced gravity (10(-4)g) was performed on three ballistic rocket flights provided by the German Sounding Rocket Programme TEXUS (Technologische Experimente unter Schwerelosigkeit = Technological Experiments in Microgravity). The described TEXUS experiment module consists of a standard experiment housing with batteries, cooling and heating systems, timer, and a data recording unit. Typically, 60 min before launch an experiment plug-in unit containing chambers with the plant material, the fixation system, and the temperature sensors is installed into the module which is already integrated in the payload section of the sounding rocket (late access). During the ballistic flight plant chambers are rapidly filled at pre-selected instants to preserve the cell structure of gravity sensing cells. After landing the plant material is processed for transmission electron microscopy. Up to now three experiments were successfully performed with cress roots (Lepidium sativum L.). Detailed improvements resulted in an automatic fixation facility which in principle can be used in unmanned missions.

  9. Recommendations for dealing with waste contaminated with Ebola virus: a Hazard Analysis of Critical Control Points approach.

    PubMed

    Edmunds, Kelly L; Elrahman, Samira Abd; Bell, Diana J; Brainard, Julii; Dervisevic, Samir; Fedha, Tsimbiri P; Few, Roger; Howard, Guy; Lake, Iain; Maes, Peter; Matofari, Joseph; Minnigh, Harvey; Mohamedani, Ahmed A; Montgomery, Maggie; Morter, Sarah; Muchiri, Edward; Mudau, Lutendo S; Mutua, Benedict M; Ndambuki, Julius M; Pond, Katherine; Sobsey, Mark D; van der Es, Mike; Zeitoun, Mark; Hunter, Paul R

    2016-06-01

    To assess, within communities experiencing Ebola virus outbreaks, the risks associated with the disposal of human waste and to generate recommendations for mitigating such risks. A team with expertise in the Hazard Analysis of Critical Control Points framework identified waste products from the care of individuals with Ebola virus disease and constructed, tested and confirmed flow diagrams showing the creation of such products. After listing potential hazards associated with each step in each flow diagram, the team conducted a hazard analysis, determined critical control points and made recommendations to mitigate the transmission risks at each control point. The collection, transportation, cleaning and shared use of blood-soiled fomites and the shared use of latrines contaminated with blood or bloodied faeces appeared to be associated with particularly high levels of risk of Ebola virus transmission. More moderate levels of risk were associated with the collection and transportation of material contaminated with bodily fluids other than blood, shared use of latrines soiled with such fluids, the cleaning and shared use of fomites soiled with such fluids, and the contamination of the environment during the collection and transportation of blood-contaminated waste. The risk of the waste-related transmission of Ebola virus could be reduced by the use of full personal protective equipment, appropriate hand hygiene and an appropriate disinfectant after careful cleaning. Use of the Hazard Analysis of Critical Control Points framework could facilitate rapid responses to outbreaks of emerging infectious disease.

  10. On the interaction of a vibrating plate with an acoustic medium

    NASA Technical Reports Server (NTRS)

    Mixson, J. S.; Koval, L. R.

    1974-01-01

    The interaction of a vibrating plate with an adjacent acoustic medium is important in problems involving the radiation of sound from panels, in problems involving the transmission of sound through walls of buildings, aircraft, or launch vehicles; and in problems involving the estimation of damping and the stress amplitude of vibration for panel-fatigue predictions. There appear to have been no systematic studies of the effects on the plate of fluid coupling for an arbitrary fluid-mass/plate-mass loading ratio. An attempt is made to determine this effect for a wide range of fluid-plate mass ratios without resorting to the usual simplifications of light or heavy fluid loading. Emphasis is with the plate motion rather than the radiation of sound.

  11. Self-powered automatic secondary air controllers for woodstoves and small furnaces

    DOEpatents

    Siemer, Darryl D.

    1991-01-01

    A controller for automatically regulating the supply of secondary combustion air to woodstoves and small furnaces. The controller includes a movable air valve for controlling the amount of secondary air admitted into the chamber. A self powered means monitors the concentration of combustible gases and vapors and actuates the movable air valve to increase the supply of secondary air in response to increasing concentrations of the combustible gases and vapors. The self-powered means can be two fluid filled sensor bulbs, one of which has a coating of a combustion catalyst. Alternatively, the self powered means can be two metallic stripes laminated together, one of which is coated with a combustion catalyst, and when heated, causes the air valve to actuate.

  12. Algorithms for the automatic generation of 2-D structured multi-block grids

    NASA Technical Reports Server (NTRS)

    Schoenfeld, Thilo; Weinerfelt, Per; Jenssen, Carl B.

    1995-01-01

    Two different approaches to the fully automatic generation of structured multi-block grids in two dimensions are presented. The work aims to simplify the user interactivity necessary for the definition of a multiple block grid topology. The first approach is based on an advancing front method commonly used for the generation of unstructured grids. The original algorithm has been modified toward the generation of large quadrilateral elements. The second method is based on the divide-and-conquer paradigm with the global domain recursively partitioned into sub-domains. For either method each of the resulting blocks is then meshed using transfinite interpolation and elliptic smoothing. The applicability of these methods to practical problems is demonstrated for typical geometries of fluid dynamics.

  13. Automatic Dependent Surveillance Broadcast (ADS-B) System for Ownership and Traffic Situational Awareness

    NASA Technical Reports Server (NTRS)

    Arteaga, Ricardo A. (Inventor)

    2016-01-01

    The present invention proposes an automatic dependent surveillance broadcast (ADS-B) architecture and process, in which priority aircraft and ADS-B IN traffic information are included in the transmission of data through the telemetry communications to a remote ground control station. The present invention further proposes methods for displaying general aviation traffic information in three and/or four dimension trajectories using an industry standard Earth browser for increased situation awareness and enhanced visual acquisition of traffic for conflict detection. The present invention enable the applications of enhanced visual acquisition of traffic, traffic alerts, and en-route and terminal surveillance used to augment pilot situational awareness through ADS-B IN display and information in three or four dimensions for self-separation awareness.

  14. Numerical analysis and experiment research on fluid orbital performance of vane type propellant management device

    NASA Astrophysics Data System (ADS)

    Hu, Q.; Li, Y.; Pan, H. L.; Liu, J. T.; Zhuang, B. T.

    2015-01-01

    Vane type propellant management device (PMD) is one of the key components of the vane-type surface tension tank (STT), and its fluid orbital performance directly determines the STT's success or failure. In present paper, numerical analysis and microgravity experiment study on fluid orbital performance of a vane type PMD were carried out. By using two-phase flow model of volume of fluid (VOF), fluid flow characteristics in the tank with the vane type PMD were numerically calculated, and the rules of fluid transfer and distribution were gotten. A abbreviate model test system of the vane type PMD is established and microgravity drop tower tests were performed, then fluid management and transmission rules of the vane type PMD were obtained under microgravity environment. The analysis and tests results show that the vane type PMD has good and initiative fluid orbital management ability and meets the demands of fluid orbital extrusion in the vane type STT. The results offer valuable guidance for the design and optimization of the new generation of vane type PMD, and also provide a new approach for fluid management and control in space environment.

  15. Data Point Averaging for Computational Fluid Dynamics Data

    NASA Technical Reports Server (NTRS)

    Norman, Jr., David (Inventor)

    2016-01-01

    A system and method for generating fluid flow parameter data for use in aerodynamic heating analysis. Computational fluid dynamics data is generated for a number of points in an area on a surface to be analyzed. Sub-areas corresponding to areas of the surface for which an aerodynamic heating analysis is to be performed are identified. A computer system automatically determines a sub-set of the number of points corresponding to each of the number of sub-areas and determines a value for each of the number of sub-areas using the data for the sub-set of points corresponding to each of the number of sub-areas. The value is determined as an average of the data for the sub-set of points corresponding to each of the number of sub-areas. The resulting parameter values then may be used to perform an aerodynamic heating analysis.

  16. Data Point Averaging for Computational Fluid Dynamics Data

    NASA Technical Reports Server (NTRS)

    Norman, David, Jr. (Inventor)

    2014-01-01

    A system and method for generating fluid flow parameter data for use in aerodynamic heating analysis. Computational fluid dynamics data is generated for a number of points in an area on a surface to be analyzed. Sub-areas corresponding to areas of the surface for which an aerodynamic heating analysis is to be performed are identified. A computer system automatically determines a sub-set of the number of points corresponding to each of the number of sub-areas and determines a value for each of the number of sub-areas using the data for the sub-set of points corresponding to each of the number of sub-areas. The value is determined as an average of the data for the sub-set of points corresponding to each of the number of sub-areas. The resulting parameter values then may be used to perform an aerodynamic heating analysis.

  17. Overview of Sensitivity Analysis and Shape Optimization for Complex Aerodynamic Configurations

    NASA Technical Reports Server (NTRS)

    Newman, Perry A.; Newman, James C., III; Barnwell, Richard W.; Taylor, Arthur C., III; Hou, Gene J.-W.

    1998-01-01

    This paper presents a brief overview of some of the more recent advances in steady aerodynamic shape-design sensitivity analysis and optimization, based on advanced computational fluid dynamics. The focus here is on those methods particularly well- suited to the study of geometrically complex configurations and their potentially complex associated flow physics. When nonlinear state equations are considered in the optimization process, difficulties are found in the application of sensitivity analysis. Some techniques for circumventing such difficulties are currently being explored and are included here. Attention is directed to methods that utilize automatic differentiation to obtain aerodynamic sensitivity derivatives for both complex configurations and complex flow physics. Various examples of shape-design sensitivity analysis for unstructured-grid computational fluid dynamics algorithms are demonstrated for different formulations of the sensitivity equations. Finally, the use of advanced, unstructured-grid computational fluid dynamics in multidisciplinary analyses and multidisciplinary sensitivity analyses within future optimization processes is recommended and encouraged.

  18. An efficient passive planar micromixer with ellipse-like micropillars for continuous mixing of human blood.

    PubMed

    Tran-Minh, Nhut; Dong, Tao; Karlsen, Frank

    2014-10-01

    In this paper, a passive planar micromixer with ellipse-like micropillars is proposed to operate in the laminar flow regime for high mixing efficiency. With a splitting and recombination (SAR) concept, the diffusion distance of the fluids in a micromixer with ellipse-like micropillars was decreased. Thus, space usage for micromixer of an automatic sample collection system is also minimized. Numerical simulation was conducted to evaluate the performance of proposed micromixer by solving the governing Navier-Stokes equation and convection-diffusion equation. With software (COMSOL 4.3) for computational fluid dynamics (CFD) we simulated the mixing of fluids in a micromixer with ellipse-like micropillars and basic T-type mixer in a laminar flow regime. The efficiency of the proposed micromixer is shown in numerical results and is verified by measurement results. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. On simulation of no-slip condition in the method of discrete vortices

    NASA Astrophysics Data System (ADS)

    Shmagunov, O. A.

    2017-10-01

    When modeling flows of an incompressible fluid, it is convenient sometimes to use the method of discrete vortices (MDV), where the continuous vorticity field is approximated by a set of discrete vortex elements moving in the velocity field. The vortex elements have a clear physical interpretation, they do not require the construction of grids and are automatically adaptive, since they concentrate in the regions of greatest interest and successfully describe the flows of a non-viscous fluid. The possibility of using MDV in simulating flows of a viscous fluid was considered in the previous papers using the examples of flows past bodies with sharp edges with the no-penetration condition at solid boundaries. However, the appearance of vorticity on smooth boundaries requires the no-slip condition to be met when MDV is realized, which substantially complicates the initially simple method. In this connection, an approach is considered that allows solving the problem by simple means.

  20. Translator for Optimizing Fluid-Handling Components

    NASA Technical Reports Server (NTRS)

    Landon, Mark; Perry, Ernest

    2007-01-01

    A software interface has been devised to facilitate optimization of the shapes of valves, elbows, fittings, and other components used to handle fluids under extreme conditions. This software interface translates data files generated by PLOT3D (a NASA grid-based plotting-and- data-display program) and by computational fluid dynamics (CFD) software into a format in which the files can be read by Sculptor, which is a shape-deformation- and-optimization program. Sculptor enables the user to interactively, smoothly, and arbitrarily deform the surfaces and volumes in two- and three-dimensional CFD models. Sculptor also includes design-optimization algorithms that can be used in conjunction with the arbitrary-shape-deformation components to perform automatic shape optimization. In the optimization process, the output of the CFD software is used as feedback while the optimizer strives to satisfy design criteria that could include, for example, improved values of pressure loss, velocity, flow quality, mass flow, etc.

  1. Analysis of cannabis in oral fluid specimens by GC-MS with automatic SPE.

    PubMed

    Choi, Hyeyoung; Baeck, Seungkyung; Kim, Eunmi; Lee, Sooyeun; Jang, Moonhee; Lee, Juseon; Choi, Hwakyung; Chung, Heesun

    2009-12-01

    Methamphetamine (MA) is the most commonly abused drug in Korea, followed by cannabis. Traditionally, MA analysis is carried out on both urine and hair samples and cannabis analysis in urine samples only. Despite the fact that oral fluid has become increasingly popular as an alternative specimen in the field of driving under the influence of drugs (DUID) and work place drug testing, its application has not been expanded to drug analysis in Korea. Oral fluid is easy to collect and handle and can provide an indication of recent drug abuse. In this study, we present an analytical method using GC-MS to determine tetrahydrocannabinol (THC) and its main metabolite 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in oral fluid. The validated method was applied to oral fluid samples collected from drug abuse suspects and the results were compared with those in urine. The stability of THC and THC-COOH in oral fluid stored in different containers was also investigated. Oral fluid specimens from 12 drug abuse suspects, submitted by the police, were collected by direct expectoration. The samples were screened with microplate ELISA. For confirmation they were extracted using automated SPE with mixed-mode cation exchange cartridge, derivatized and analyzed by GC-MS using selective ion monitoring (SIM). The concentrations ofTHC and THC-COOH in oral fluid showed a large variation and the results from oral fluid and urine samples from cannabis abusers did not show any correlation. Thus, detailed information about time interval between drug use and sample collection is needed to interpret the oral fluid results properly. In addition, further investigation about the detection time window ofTHC and THC-COOH in oral fluid is required to substitute oral fluid for urine in drug testing.

  2. Fractured-aquifer hydrogeology from geophysical logs; the passaic formation, New Jersey

    USGS Publications Warehouse

    Morin, R.H.; Carleton, G.B.; Poirier, S.

    1997-01-01

    The Passaic Formation consists of gradational sequences of mudstone, siltstone, and sandstone, and is a principal aquifer in central New Jersey. Ground-water flow is primarily controlled by fractures interspersed throughout these sedimentary rocks and characterizing these fractures in terms of type, orientation, spatial distribution, frequency, and transmissivity is fundamental towards understanding local fluid-transport processes. To obtain this information, a comprehensive suite of geophysical logs was collected in 10 wells roughly 46 m in depth and located within a .05 km2 area in Hopewell Township, New Jersey. A seemingly complex, heterogeneous network of fractures identified with an acoustic televiewer was statistically reduced to two principal subsets corresponding to two distinct fracture types: (1) bedding-plane partings and (2) high-angle fractures. Bedding-plane partings are the most numerous and have an average strike of N84??W and dip of 20??N. The high-angle fractures are oriented subparallel to these features, with an average strike of N79??E and dip of 71??S, making the two fracture types roughly orthogonal. Their intersections form linear features that also retain this approximately east-west strike. Inspection of fluid temperature and conductance logs in conjunction with flowmeter measurements obtained during pumping allows the transmissive fractures to be distinguished from the general fracture population. These results show that, within the resolution capabilities of the logging tools, approximately 51 (or 18 percent) of the 280 total fractures are water producing. The bedding-plane partings exhibit transmissivities that average roughly 5 m2/day and that generally diminish in magnitude and frequency with depth. The high-angle fractures have average transmissivities that are about half those of the bedding-plane partings and show no apparent dependence upon depth. The geophysical logging results allow us to infer a distinct hydrogeologic structure within this aquifer that is defined by fracture type and orientation. Fluid flow near the surface is controlled primarily by the highly transmissive, subhorizontal bedding-plane partings. As depth increases, the high-angle fractures apparently become more dominant hydrologically.The Passaic Formation consists of gradational sequences of mudstone, siltstone, and sandstone, and is a principal aquifer in central New Jersey. Ground-water flow is primarily controlled by fractures interspersed throughout these sedimentary rocks and characterizing these fractures in terms of type, orientation, spatial distribution, frequency, and transmissivity is fundamental towards understanding local fluid-transport processes. To obtain this information, a comprehensive suite of geophysical logs was collected in 10 wells roughly 46 m in depth and located within a .05 km2 area in Hopewell Township, New Jersey. A seemingly complex, heterogeneous network of fractures identified with an acoustic televiewer was statistically reduced to two principal subsets corresponding to two distinct fracture types: (1) bedding-plane partings and (2) high-angle fractures. Bedding-plane partings are the most numerous and have an average strike of N84?? W and dip of 20?? N. The high-angle fractures are oriented subparallel to these features, with an average strike of N79?? E and dip of 71?? S, making the two fracture types roughly orthogonal. Their intersections form linear features that also retain this approximately east-west strike. Inspection of fluid temperature and conductance logs in conjunction with flowmeter measurements obtained during pumping allows the transmissive fractures to be distinguished from the general fracture population. These results show that, within the resolution capabilities of the logging tools, approximately 51 (or 18 percent) of the 280 total fractures are water producing. The bedding-plane partings exhibit transmissivities that average roughly 5 m2/day and that generally dimi

  3. Adaptive particle-based pore-level modeling of incompressible fluid flow in porous media: a direct and parallel approach

    NASA Astrophysics Data System (ADS)

    Ovaysi, S.; Piri, M.

    2009-12-01

    We present a three-dimensional fully dynamic parallel particle-based model for direct pore-level simulation of incompressible viscous fluid flow in disordered porous media. The model was developed from scratch and is capable of simulating flow directly in three-dimensional high-resolution microtomography images of naturally occurring or man-made porous systems. It reads the images as input where the position of the solid walls are given. The entire medium, i.e., solid and fluid, is then discretized using particles. The model is based on Moving Particle Semi-implicit (MPS) technique. We modify this technique in order to improve its stability. The model handles highly irregular fluid-solid boundaries effectively. It takes into account viscous pressure drop in addition to the gravity forces. It conserves mass and can automatically detect any false connectivity with fluid particles in the neighboring pores and throats. It includes a sophisticated algorithm to automatically split and merge particles to maintain hydraulic connectivity of extremely narrow conduits. Furthermore, it uses novel methods to handle particle inconsistencies and open boundaries. To handle the computational load, we present a fully parallel version of the model that runs on distributed memory computer clusters and exhibits excellent scalability. The model is used to simulate unsteady-state flow problems under different conditions starting from straight noncircular capillary tubes with different cross-sectional shapes, i.e., circular/elliptical, square/rectangular and triangular cross-sections. We compare the predicted dimensionless hydraulic conductances with the data available in the literature and observe an excellent agreement. We then test the scalability of our parallel model with two samples of an artificial sandstone, samples A and B, with different volumes and different distributions (non-uniform and uniform) of solid particles among the processors. An excellent linear scalability is obtained for sample B that has more uniform distribution of solid particles leading to a superior load balancing. The model is then used to simulate fluid flow directly in REV size three-dimensional x-ray images of a naturally occurring sandstone. We analyze the quality and consistency of the predicted flow behavior and calculate absolute permeability, which compares well with the available network modeling and Lattice-Boltzmann permeabilities available in the literature for the same sandstone. We show that the model conserves mass very well and is stable computationally even at very narrow fluid conduits. The transient- and the steady-state fluid flow patterns are presented as well as the steady-state flow rates to compute absolute permeability. Furthermore, we discuss the vital role of our adaptive particle resolution scheme in preserving the original pore connectivity of the samples and their narrow channels through splitting and merging of fluid particles.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bolenbaugh, Jonathan M.; Naqi, Syed

    A method to operate a clutch device in an electro-mechanical transmission mechanically-operatively coupled to an internal combustion engine and at least one electric machine includes, in response to a failure condition detected within a flow control device configured to facilitate flow of hydraulic fluid for operating the clutch device, selectively preventing the flow of hydraulic fluid from entering the flow control device and feeding the clutch device. Synchronization of the clutch device is initiated when the clutch device is intended for activation, and only if the clutch device is synchronized, the flow of hydraulic fluid is selectively permitted to entermore » the flow control device to activate the clutch device.« less

  5. [Changes in the peritoneum of the small intestine and diaphragm in experimental portal hypertension].

    PubMed

    Khoroshaev, V A; Vorozheĭkin, V M; Baĭbekov, I M

    1991-04-01

    Diaphragm and small intestine peritoneum morphology was studied in experimental portal hypertension in rats with the help of luminescent, transmission and scanning electron microscopy techniques. Structural organizations of these peritoneum portions and performance function were different: fluid transudation realized through the small intestine peritoneum and resorption occurred via diaphragm peritoneum. Morphological signs allowed to judge about the increasing of fluid transudation in abdominal cavity and diaphragmatic resorption in early period of portal hypertension. Morphological alterations appeared in peritoneum resorption sites (pumping diaphragmatic hatchs) according to progress of portal hypertension that indicated decompensation process of peritoneal fluid absorption and led to ascites.

  6. Progress on advanced dc and ac induction drives for electric vehicles

    NASA Technical Reports Server (NTRS)

    Schwartz, H. J.

    1982-01-01

    Progress is reported in the development of complete electric vehicle propulsion systems, and the results of tests on the Road Load Simulator of two such systems representative of advanced dc and ac drive technology are presented. One is the system used in the DOE's ETV-1 integrated test vehicle which consists of a shunt wound dc traction motor under microprocessor control using a transistorized controller. The motor drives the vehicle through a fixed ratio transmission. The second system uses an ac induction motor controlled by transistorized pulse width modulated inverter which drives through a two speed automatically shifted transmission. The inverter and transmission both operate under the control of a microprocessor. The characteristics of these systems are also compared with the propulsion system technology available in vehicles being manufactured at the inception of the DOE program and with an advanced, highly integrated propulsion system upon which technology development was recently initiated.

  7. Gas turbine engines and transmissions for bus demonstration programs. Technical status report, 31 July 1979--31 October 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nigro, D.N.

    1979-11-01

    The report summarizes the DDA activities for the effort performed on the procurement and delivery of eleven Allison GT 404-4 gas turbine engines and five HT740CT and six V730CT Allison automatic transmissions and the required associated software. The contract requires the delivery of the engines and transmissions for the Greyhound and Transit Coaches, respectively. In addition, software items such as cost reports, technical reports, installation drawings, acceptance test data and parts lists are required. A recent decision by the DOE will modify the build configuration for the last four (4) Transit Coach engines. It was decided by the DOE atmore » a meeting in Washington, DC on March 28, 1979 with representatives from DDA, NASA/LeRC, JPL and Booz-Allen and Hamilton that these engines are to be built with ceramic regenerators. (TFD)« less

  8. Monitoring of Overhead Transmission Lines: A Review from the Perspective of Contactless Technologies

    NASA Astrophysics Data System (ADS)

    Khawaja, Arsalan Habib; Huang, Qi; Khan, Zeashan Hameed

    2017-12-01

    This paper describes a comprehensive review of non-contact technologies for overhead power transmission lines. Due to ever increasing emphasis on reducing accidents and speeding up diagnosis for automatically controlled grids, real time remote sensing and actuation is the new horizon for smart grid implementation. The technology overview with emphasis on the practical implementation of advanced non-contact technologies is discussed in this paper while considering optimization of the high voltage transmission lines parameters. In case of fault, the voltage and the current exceed limits of operation and hence real time reporting for control and diagnosis is a critical requirement. This paper aims to form a strong foundation for control and diagnosis of future power distribution systems so that a practitioner or researcher can make choices for a workable solution in smart grid implementation based on non-contact sensing.

  9. Multicoaxial cylindrical inclusions in locally resonant phononic crystals

    NASA Astrophysics Data System (ADS)

    Larabi, H.; Pennec, Y.; Djafari-Rouhani, B.; Vasseur, J. O.

    2007-06-01

    It is known that the transmission spectrum of the so-called locally resonant phononic crystal can exhibit absolute sharp dips in the sonic frequency range due to the resonance scattering of elastic waves. In this paper, we study theoretically, using a finite difference time domain method, the propagation of acoustic waves through a two-dimensional locally resonant crystal in which the matrix is a fluid (such as water) instead of being a solid as in most of the previous papers. The transmission is shown to be dependent upon the fluid or solid nature of the matrix as well as upon the nature of the coating material in contact with the matrix. The other main purpose of this paper is to consider inclusions constituted by coaxial cylindrical multilayers consisting of several alternate shells of a soft material (such as a soft rubber) and a hard material (such as steel). With respect to the usual case of a hard core coated with a soft rubber, the transmission spectrum can exhibit in the same frequency range several peaks instead of one. If two or more phononic crystals are associated together, we find that the structure displays all the zeros of transmission resulting from each individual crystal. Moreover, we show that it is possible to overlap the dips by an appropriate combination of phononic crystals and create a larger acoustic stop band.

  10. Control of intrauterine fluid pressure during operative hysteroscopy.

    PubMed

    Shirk, G J; Gimpelson, R J

    1994-05-01

    To evaluate the safety of a commonly used piston pump that controls the infusion pressure of low-viscosity fluids in a continuous-flow hysteroscopic system during operative hysteroscopy. Consecutive patients requiring operative hysteroscopy. Three hospital facilities in the Midwest. Sequential sample of 250 women who underwent operative hysteroscopy. Endometrial ablations, resection of submucosal or pedunculated uterine leiomyomata with or without endometrial ablation, polyp resections, metroplasty, and lysis of synechiae. The most serious complication of operative hysteroscopy is fluid overload due to intravasation into the patient's vascular system. Low-viscosity fluids were infused by the Zimmer Controlled Distention Irrigation System. The instrument uses a closed-feedback loop to monitor cavity pressure and automatically regulates the flow to maintain the set point pressure. It is designed to operate in a pressure range of 0 to 80 mm Hg and at flows in excess of 450 ml/minute. In 250 operative hysteroscopies no fluid complications occurred when intrauterine pressure was maintained below 80 mm Hg. No clinically significant differences in intravasation were seen in any type of operative hysteroscopy. This controlled mechanical pump system with exact intrauterine pressure measurement reduced many technical difficulties associated with low-viscosity media, and created a safe environment for the media's use in operative hysteroscopy.

  11. Simultaneous orientation and thickness mapping in transmission electron microscopy

    DOE PAGES

    Tyutyunnikov, Dmitry; Özdöl, V. Burak; Koch, Christoph T.

    2014-12-04

    In this paper we introduce an approach for simultaneous thickness and orientation mapping of crystalline samples by means of transmission electron microscopy. We show that local thickness and orientation values can be extracted from experimental dark-field (DF) image data acquired at different specimen tilts. The method has been implemented to automatically acquire the necessary data and then map thickness and crystal orientation for a given region of interest. We have applied this technique to a specimen prepared from a commercial semiconductor device, containing multiple 22 nm technology transistor structures. The performance and limitations of our method are discussed and comparedmore » to those of other techniques available.« less

  12. Systems analysis of the space shuttle. [communication systems, computer systems, and power distribution

    NASA Technical Reports Server (NTRS)

    Schilling, D. L.; Oh, S. J.; Thau, F.

    1975-01-01

    Developments in communications systems, computer systems, and power distribution systems for the space shuttle are described. The use of high speed delta modulation for bit rate compression in the transmission of television signals is discussed. Simultaneous Multiprocessor Organization, an approach to computer organization, is presented. Methods of computer simulation and automatic malfunction detection for the shuttle power distribution system are also described.

  13. Skylab 2 Solar Physics Experiment

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Skylab 2 Solar Physics Experiment. This black and white view of a solar flare was taken from the skylab remote solar experiment module mounted on top of the vehicle and worked automatically without any interaction from the crew. Solar flares or sunspots are eruptions on the sun's surface and appear to occur in cycles. When these cycles occur, there is worldwide electromagnetic interference affecting radio and television transmission.

  14. A Survivable Wavelength Division Multiplexing Passive Optical Network with Both Point-to-Point Service and Broadcast Service Delivery

    NASA Astrophysics Data System (ADS)

    Ma, Xuejiao; Gan, Chaoqin; Deng, Shiqi; Huang, Yan

    2011-11-01

    A survivable wavelength division multiplexing passive optical network enabling both point-to-point service and broadcast service is presented and demonstrated. This architecture provides an automatic traffic recovery against feeder and distribution fiber link failure, respectively. In addition, it also simplifies the protection design for multiple services transmission in wavelength division multiplexing passive optical networks.

  15. 14 CFR 91.227 - Automatic Dependent Surveillance-Broadcast (ADS-B) Out equipment performance requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 0.2 nautical miles; (iv) The aircraft's SDA must be 2; and (v) The aircraft's SIL must be 3. (2... geometric position no later than 2.0 seconds from the time of measurement of the position to the time of transmission. (2) Within the 2.0 total latency allocation, a maximum of 0.6 seconds can be uncompensated...

  16. Automatic Adaptation of Tunable Distributed Applications

    DTIC Science & Technology

    2001-01-01

    size, weight, and battery life, with a single CPU, less memory, smaller hard disk, and lower bandwidth network connectivity. The power of PDAs is...wireless, and bluetooth [32] facilities; thus achieving different rates of data transmission. 1 With the trend of “write once, run everywhere...applications, a single component can execute on multiple processors (or machines) in parallel. These parallel applications, written in a specialized language

  17. Surface self-potential patterns related to transmissive fracture trends during a water injection test

    NASA Astrophysics Data System (ADS)

    DesRoches, A. J.; Butler, K. E.; MacQuarrie, K. TB

    2018-03-01

    Variations in self-potential (SP) signals were recorded over an electrode array during a constant head injection test in a fractured bedrock aquifer. Water was injected into a 2.2 m interval isolated between two inflatable packers at 44 m depth in a vertical well. Negative SP responses were recorded on surface corresponding to the start of the injection period with strongest magnitudes recorded in electrodes nearest the well. SP response decreased in magnitude at electrodes further from the well. Deflation of the packer system resulted in a strong reversal in the SP signal. Anomalous SP patterns observed at surface at steady state were found to be aligned with dominant fracture strike orientations found within the test interval. Numerical modelling of fluid and current flow within a simplified fracture network showed that azimuthal patterns in SP are mainly controlled by transmissive fracture orientations. The strongest SP gradients occur parallel to hydraulic gradients associated with water flowing out of the transmissive fractures into the tighter matrix and other less permeable cross-cutting fractures. Sensitivity studies indicate that increasing fracture frequency near the well increases the SP magnitude and enhances the SP anomaly parallel to the transmissive set. Decreasing the length of the transmissive fractures leads to more fluid flow into the matrix and into cross-cutting fractures proximal to the well, resulting in a more circular and higher magnitude SP anomaly. Results from the field experiment and modelling provide evidence that surface-based SP monitoring during constant head injection tests has the ability to identify groundwater flow pathways within a fractured bedrock aquifer.

  18. Plasmonic fiber-optic vector magnetometer

    NASA Astrophysics Data System (ADS)

    Zhang, Zhaochuan; Guo, Tuan; Zhang, Xuejun; Xu, Jian; Xie, Wenping; Nie, Ming; Wu, Qiang; Guan, Bai-Ou; Albert, Jacques

    2016-03-01

    A compact fiber-optic vector magnetometer based on directional scattering between polarized plasmon waves and ferro-magnetic nanoparticles is demonstrated. The sensor configuration reported in this work uses a short section of tilted fiber Bragg grating (TFBG) coated with a nanometer scale gold film and packaged with a magnetic fluid (Fe3O4) inside a capillary. The transmission spectrum of the sensor provides a fine comb of narrowband resonances that overlap with a broader absorption of the surface plasmon resonance (SPR). The wavelength of the SPR attenuation in transmission shows high sensitivity to slight perturbations by magnetic fields, due to the strong directional scattering between the SPR attenuated cladding modes and the magnetic fluid near the fiber surface. Both the orientation (2 nm/deg) and the intensity (1.8 nm/mT) of magnetic fields can be determined unambiguously from the TFBG spectrum. Temperature cross sensitivity can be referenced out by monitoring the wavelength of the core mode resonance simultaneously.

  19. Controlling the angle range in acoustic low-frequency forbidden transmission in solid-fluid superlattice

    NASA Astrophysics Data System (ADS)

    Zhang, Sai; Xu, Bai-qiang; Cao, Wenwu

    2018-03-01

    We have investigated low-frequency forbidden transmission (LFT) of acoustic waves with frequency lower than the first Bragg bandgap in a solid-fluid superlattice (SFSL). LFT is formed when the acoustic planar wave impinges on the interface of a SFSL within a certain angle range. However, for the SFSL comprised of metallic material and water, the angle range of LFT is extremely narrow, which restricts its practical applications. The variation characteristics of the angle range have been comprehensively studied here by the control variable method. The results suggest that the filling ratio, layer number, wave velocity, and mass density of the constituent materials have a significant impact on the angle range. Based on our results, an effective strategy for obtaining LFT with a broad angle range is provided, which will be useful for potential applications of LFT in various devices, such as low frequency filters and subwavelength one-way diodes.

  20. Influence of gas law on ultrasonic behaviour of porous media under pressure.

    PubMed

    Griffiths, S; Ayrault, C

    2010-06-01

    This paper deals with the influence of gas law on ultrasonic behaviour of porous media when the saturating fluid is high pressured. Previous works have demonstrated that ultrasonic transmission through a porous sample with variations of the static pressure (up to 18 bars) of the saturating fluid allows the characterization of high damping materials. In these studies, the perfect gas law was used to link static pressure and density, which is disputable for high pressures. This paper compares the effects of real and perfect gas laws on modeled transmission coefficient for porous foams at these pressures. Direct simulations and a mechanical parameters estimation from minimization show that results are very similar in both cases. The real gas law is thus not necessary to describe the acoustic behaviour of porous media at low ultrasonic frequencies (100 kHz) up to 20 bars. 2010 Elsevier B.V. All rights reserved.

  1. Evaluation of damping loss factor of flat laminates by sound transmission

    NASA Astrophysics Data System (ADS)

    Parrinello, A.; Ghiringhelli, G. L.

    2018-06-01

    A novel approach to investigate and evaluate the damping loss factor of a planar multilayered structure is presented. A statistical analysis reveals the connection between the damping properties of the structure and the transmission of sound through the thickness of its laterally infinite counterpart. The obtained expression for the panel loss factor involves all the derivatives of the transmission and reflection coefficients of the layered structure with respect each layer damping. The properties of the fluid for which the sound transmission is evaluated are chosen to fulfil the hypotheses on the basis of the statistical formulation. A transfer matrix approach is used to compute the required transmission and reflection coefficients, making it possible to deal with structures having arbitrary stratifications of different layers and also granting high efficiency in a wide frequency range. Comparison with alternative formulations and measurements demonstrates the effectiveness of the proposed methodology.

  2. Data transmission element for downhole drilling components

    DOEpatents

    Hall, David R.; Hall, Jr., H. Tracy; Pixton, David S.; Dahlgren, Scott; Fox, Joe; Sneddon, Cameron; Briscoe, Michael

    2006-01-31

    A robust data transmission element for transmitting information between downhole components, such as sections of drill pipe, in the presence of hostile environmental conditions, such as heat, dirt, rocks, mud, fluids, lubricants, and the like. The data transmission element components include a generally U-shaped annular housing, a generally U-shaped magnetically conductive, electrically insulating element such as ferrite, and an insulated conductor. Features on the magnetically conducting, electrically insulating element and the annular housing create a pocket when assembled. The data transmission element is filled with a polymer to retain the components within the annular housing by filling the pocket with the polymer. The polymer can bond with the annular housing and the insulated conductor but preferably not the magnetically conductive, electrically insulating element. A data transmission element is mounted within a recess proximate a mating surface of a downhole drilling component, such as a section of drill pipe.

  3. Aerobiology and Its Role in the Transmission of Infectious Diseases

    PubMed Central

    Fernstrom, Aaron; Goldblatt, Michael

    2013-01-01

    Aerobiology plays a fundamental role in the transmission of infectious diseases. As infectious disease and infection control practitioners continue employing contemporary techniques (e.g., computational fluid dynamics to study particle flow, polymerase chain reaction methodologies to quantify particle concentrations in various settings, and epidemiology to track the spread of disease), the central variables affecting the airborne transmission of pathogens are becoming better known. This paper reviews many of these aerobiological variables (e.g., particle size, particle type, the duration that particles can remain airborne, the distance that particles can travel, and meteorological and environmental factors), as well as the common origins of these infectious particles. We then review several real-world settings with known difficulties controlling the airborne transmission of infectious particles (e.g., office buildings, healthcare facilities, and commercial airplanes), while detailing the respective measures each of these industries is undertaking in its effort to ameliorate the transmission of airborne infectious diseases. PMID:23365758

  4. Research on the laser transmission characteristics simulation and comprehensive test in complex channel environment

    NASA Astrophysics Data System (ADS)

    Fu, Qiang; Liu, Jianhua; Wang, Xiaoman; Jiang, Huilin; Liu, Zhi

    2014-12-01

    The laser transmission characteristics affected in the complex channel environment, which limits the performance of laser equipment and engineering application severely. The article aim at the influence of laser transmission in atmospheric and seawater channels, summarizes the foreign researching work of the simulation and comprehensive test regarding to the laser transmission characteristics in complex environment. And researched the theory of atmospheric turbulence effect, water attenuation features, and put forward the corresponding theoretical model. And researched the simulate technology of atmospheric channel and sea water channel, put forward the analog device plan, adopt the similar theory of flowing to simulate the atmosphere turbulence .When the flowing has the same condition of geometric limits including the same Reynolds, they must be similar to each other in the motivation despite of the difference in the size, speed, and intrinsic quality. On this basis, set up a device for complex channel simulation and comprehensive testing, the overall design of the structure of the device, Hot and Cold Air Convection Simulation of Atmospheric Turbulence, mainly consists of cell body, heating systems, cooling systems, automatic control system. he simulator provides platform and method for the basic research of laser transmission characteristics in the domestic.

  5. Eclipse SteerTech liquid lenslet beam steering technology

    NASA Astrophysics Data System (ADS)

    Westfall, Raymond T.; Rogers, Stanley; Shannon, Kenneth C., III

    2007-09-01

    Eclipse SteerTech TM transmissive fluid state electrowetting technology has successfully demonstrated the ability to control the shape and position of a fluid lenslet. In its final form, the technology will incorporate a dual fluid lenslet approach capable of operating in extremely high acceleration environments. The beam steering system works on the principle of electro-wetting. A substrate is covered with a closely spaced array of, independently addressable, transparent, electrically conductive pixels utilizing Eclipse's proprietary EclipseTEC TM technology. By activating and deactivating selected EclipseTEC TM pixels in the proper sequence, the shape and position of fluid lenslets or arrays of lenslets can be dynamically changed at will. The position and shape of individual fluid lenslets may be accurately controlled on any flat, simply curved, or complex curved, transparent or reflective surface. The smaller the pixels the better control of the position and shape of the fluid lenslets. Information on the successful testing of the Eclipse SteerTech TM lenslet and discussion of its use in a de-centered lenslet array will be presented.

  6. Speckle tracking and speckle content based composite strain imaging for solid and fluid filled lesions.

    PubMed

    Rabbi, Md Shifat-E; Hasan, Md Kamrul

    2017-02-01

    Strain imaging though for solid lesions provides an effective way for determining their pathologic condition by displaying the tissue stiffness contrast, for fluid filled lesions such an imaging is yet an open problem. In this paper, we propose a novel speckle content based strain imaging technique for visualization and classification of fluid filled lesions in elastography after automatic identification of the presence of fluid filled lesions. Speckle content based strain, defined as a function of speckle density based on the relationship between strain and speckle density, gives an indirect strain value for fluid filled lesions. To measure the speckle density of the fluid filled lesions, two new criteria based on oscillation count of the windowed radio frequency signal and local variance of the normalized B-mode image are used. An improved speckle tracking technique is also proposed for strain imaging of the solid lesions and background. A wavelet-based integration technique is then proposed for combining the strain images from these two techniques for visualizing both the solid and fluid filled lesions from a common framework. The final output of our algorithm is a high quality composite strain image which can effectively visualize both solid and fluid filled breast lesions in addition to the speckle content of the fluid filled lesions for their discrimination. The performance of our algorithm is evaluated using the in vivo patient data and compared with recently reported techniques. The results show that both the solid and fluid filled lesions can be better visualized using our technique and the fluid filled lesions can be classified with good accuracy. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Boundary element analyses for sound transmission loss of panels.

    PubMed

    Zhou, Ran; Crocker, Malcolm J

    2010-02-01

    The sound transmission characteristics of an aluminum panel and two composite sandwich panels were investigated by using two boundary element analyses. The effect of air loading on the structural behavior of the panels is included in one boundary element analysis, by using a light-fluid approximation for the eigenmode series to evaluate the structural response. In the other boundary element analysis, the air loading is treated as an added mass. The effect of the modal energy loss factor on the sound transmission loss of the panels was investigated. Both boundary element analyses were used to study the sound transmission loss of symmetric sandwich panels excited by a random incidence acoustic field. A classical wave impedance analysis was also used to make sound transmission loss predictions for the two foam-filled honeycomb sandwich panels. Comparisons between predictions of sound transmission loss for the two foam-filled honeycomb sandwich panels excited by a random incidence acoustic field obtained from the wave impedance analysis, the two boundary element analyses, and experimental measurements are presented.

  8. Recommendations for dealing with waste contaminated with Ebola virus: a Hazard Analysis of Critical Control Points approach

    PubMed Central

    Edmunds, Kelly L; Elrahman, Samira Abd; Bell, Diana J; Brainard, Julii; Dervisevic, Samir; Fedha, Tsimbiri P; Few, Roger; Howard, Guy; Lake, Iain; Maes, Peter; Matofari, Joseph; Minnigh, Harvey; Mohamedani, Ahmed A; Montgomery, Maggie; Morter, Sarah; Muchiri, Edward; Mudau, Lutendo S; Mutua, Benedict M; Ndambuki, Julius M; Pond, Katherine; Sobsey, Mark D; van der Es, Mike; Zeitoun, Mark

    2016-01-01

    Abstract Objective To assess, within communities experiencing Ebola virus outbreaks, the risks associated with the disposal of human waste and to generate recommendations for mitigating such risks. Methods A team with expertise in the Hazard Analysis of Critical Control Points framework identified waste products from the care of individuals with Ebola virus disease and constructed, tested and confirmed flow diagrams showing the creation of such products. After listing potential hazards associated with each step in each flow diagram, the team conducted a hazard analysis, determined critical control points and made recommendations to mitigate the transmission risks at each control point. Findings The collection, transportation, cleaning and shared use of blood-soiled fomites and the shared use of latrines contaminated with blood or bloodied faeces appeared to be associated with particularly high levels of risk of Ebola virus transmission. More moderate levels of risk were associated with the collection and transportation of material contaminated with bodily fluids other than blood, shared use of latrines soiled with such fluids, the cleaning and shared use of fomites soiled with such fluids, and the contamination of the environment during the collection and transportation of blood-contaminated waste. Conclusion The risk of the waste-related transmission of Ebola virus could be reduced by the use of full personal protective equipment, appropriate hand hygiene and an appropriate disinfectant after careful cleaning. Use of the Hazard Analysis of Critical Control Points framework could facilitate rapid responses to outbreaks of emerging infectious disease. PMID:27274594

  9. Dynamics of African swine fever virus shedding and excretion in domestic pigs infected by intramuscular inoculation and contact transmission.

    PubMed

    Guinat, Claire; Reis, Ana Luisa; Netherton, Christopher L; Goatley, Lynnette; Pfeiffer, Dirk U; Dixon, Linda

    2014-09-26

    African swine fever virus (ASFV) is a highly virulent swine pathogen that has spread across Eastern Europe since 2007 and for which there is no effective vaccine or treatment available. The dynamics of shedding and excretion is not well known for this currently circulating ASFV strain. Therefore, susceptible pigs were exposed to pigs intramuscularly infected with the Georgia 2007/1 ASFV strain to measure those dynamics through within- and between-pen transmission scenarios. Blood, oral, nasal and rectal fluid samples were tested for the presence of ASFV by virus titration (VT) and quantitative real-time polymerase chain reaction (qPCR). Serum was tested for the presence of ASFV-specific antibodies. Both intramuscular inoculation and contact transmission resulted in development of acute disease in all pigs although the experiments indicated that the pathogenesis of the disease might be different, depending on the route of infection. Infectious ASFV was first isolated in blood among the inoculated pigs by day 3, and then chronologically among the direct and indirect contact pigs, by day 10 and 13, respectively. Close to the onset of clinical signs, higher ASFV titres were found in blood compared with nasal and rectal fluid samples among all pigs. No infectious ASFV was isolated in oral fluid samples although ASFV genome copies were detected. Only one animal developed antibodies starting after 12 days post-inoculation. The results provide quantitative data on shedding and excretion of the Georgia 2007/1 ASFV strain among domestic pigs and suggest a limited potential of this isolate to cause persistent infection.

  10. Numerical models analysis of energy conversion process in air-breathing laser propulsion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong Yanji; Song Junling; Cui Cunyan

    Energy source was considered as a key essential in this paper to describe energy conversion process in air-breathing laser propulsion. Some secondary factors were ignored when three independent modules, ray transmission module, energy source term module and fluid dynamic module, were established by simultaneous laser radiation transportation equation and fluid mechanics equation. The incidence laser beam was simulated based on ray tracing method. The calculated results were in good agreement with those of theoretical analysis and experiments.

  11. Water quality monitor. [spacecraft potable water

    NASA Technical Reports Server (NTRS)

    West, S.; Crisos, J.; Baxter, W.

    1979-01-01

    The preprototype water quality monitor (WQM) subsystem was designed based on a breadboard monitor for pH, specific conductance, and total organic carbon (TOC). The breadboard equipment demonstrated the feasibility of continuous on-line analysis of potable water for a spacecraft. The WQM subsystem incorporated these breadboard features and, in addition, measures ammonia and includes a failure detection system. The sample, reagent, and standard solutions are delivered to the WQM sensing manifold where chemical operations and measurements are performed using flow through sensors for conductance, pH, TOC, and NH3. Fault monitoring flow detection is also accomplished in this manifold assembly. The WQM is designed to operate automatically using a hardwired electronic controller. In addition, automatic shutdown is incorporated which is keyed to four flow sensors strategically located within the fluid system.

  12. Optical devices having flakes suspended in a host fluid to provide a flake/fluid system providing flakes with angularly dependent optical properties in response to an alternating current electric field due to the dielectric properties of the system

    DOEpatents

    Kosc, Tanya Z [Rochester, NY; Marshall, Kenneth L [Rochester, NY; Jacobs, Stephen D [Pittsford, NY

    2006-05-09

    Optical devices utilizing flakes (also called platelets) suspended in a host fluid have optical characteristics, such as reflective properties, which are angular dependent in response to an AC field. The reflectivity may be Bragg-like, and the characteristics are obtained through the use of flakes of liquid crystal material, such as polymer liquid crystal (PLC) materials including polymer cholesteric liquid crystal (PCLC) and polymer nematic liquid crystal (PNLC) material or birefringent polymers (BP). The host fluid may be propylene carbonate, poly(ethylene glycol) or other fluids or fluid mixtures having fluid conductivity to support conductivity in the flake/host system. AC field dependent rotation of 90.degree. can be obtained at rates and field intensities dependent upon the frequency and magnitude of the AC field. The devices are useful in providing displays, polarizers, filters, spatial light modulators and wherever switchable polarizing, reflecting, and transmission properties are desired.

  13. Droplets and modes of respiratory disease transmission

    NASA Astrophysics Data System (ADS)

    Bourouiba, Lydia

    2014-11-01

    Direct observation of violent expirations such as sneezes and coughs events reveal that such flows are multiphase turbulent buoyant clouds with suspended droplets of various sizes. The effects of ambient conditions indoors, such as moisture and temperature, coupled with the water content of such clouds are key in shaping the pathogen footprint emitted by potentially sick individuals. Such pathogen footprint can change the patterns of respiratory disease transmission. We discuss how the fluid dynamics of violent expirations can help inform how.

  14. Superiority of automatic remote monitoring compared with in-person evaluation for scheduled ICD follow-up in the TRUST trial - testing execution of the recommendations

    PubMed Central

    Varma, Niraj; Michalski, Justin; Stambler, Bruce; Pavri, Behzad B.

    2014-01-01

    Aims To test recommended implantable cardioverter defibrillator (ICD) follow-up methods by ‘in-person evaluations’ (IPE) vs. ‘remote Home Monitoring’ (HM). Methods and results ICD patients were randomized 2:1 to automatic HM or to Conventional monitoring, with follow-up checks scheduled at 3, 6, 9, 12, and 15 months post-implant. Conventional patients were evaluated with IPE only. Home Monitoring patients were assessed remotely only for 1 year between 3 and 15 month evaluations. Adherence to follow-up was measured. HM and Conventional patients were similar (age 63 years, 72% male, left ventricular ejection fraction 29%, primary prevention 73%, DDD 57%). Conventional management suffered greater patient attrition during the trial (20.1 vs. 14.2% in HM, P = 0.007). Three month follow-up occurred in 84% in both groups. There was 100% adherence (5 of 5 checks) in 47.3% Conventional vs. 59.7% HM (P < 0.001). Between 3 and 15 months, HM exhibited superior (2.2×) adherence to scheduled follow-up [incidence of failed follow up was 146 of 2421 (6.0%) in HM vs. 145 of 1098 (13.2%) in Conventional, P < 0.001] and punctuality. In HM (daily transmission success rate median 91%), transmission loss caused only 22 of 2275 (0.97%) failed HM evaluations between 3 and 15 months; others resulted from clinic oversight. Overall IPE failure rate in Conventional [193 of 1841 (10.5%) exceeded that in HM [97 of 1484 (6.5%), P < 0.001] by 62%, i.e. HM patients remained more loyal to IPE when this was mandated. Conclusion Automatic remote monitoring better preserves patient retention and adherence to scheduled follow-up compared with IPE. Clinical trial registration NCT00336284. PMID:24595864

  15. Study on Two-Phase Flow in Heterogeneous Porous Media by Light Transmission Method

    NASA Astrophysics Data System (ADS)

    Qiao, W.

    2015-12-01

    The non-aqueous phase liquid (NAPL) released to the subsurface can form residual ganglia and globules occupying pores and also accumulate and form pools, in which multiphase system forms. Determining transient fluid saturations in a multiphase system is essential to understand the flow characteristics of systems and to perform effective remediation strategies. As a non-destructive and non-invasive laboratory technique utilized for the measurement of liquid saturation in porous media, light transmission is of the lowest cost and safe. Utilization of Coupled Charge Device camera in light transmission systems provides a nearly instantaneous high-density array of spatial measurements over a very large dynamic range. The migration of NAPL and air spariging technique applied to remove NAPL in aquifer systems are typically two-phase flow problem. Because of the natural aquifer normally being heterogeneous, two 2-D sandboxes (Length55cm×width1.3cm×hight45cm) are set up to study the migration of gas and DNAPL in heterogeneous porous media based on light transmission method and its application in two-phase flow. Model D for water/gas system developed by Niemet and Selker (2001) and Model NW-A for water/NAPL system developed by Zhang et al. (2014) are applied for the calculation of fluid saturation in the two experiments, respectively. The gas injection experiments show that the gas moves upward in the irregular channels, piling up beneath the low permeability lenses and starting lateral movement. Bypassing the lenses, the gas moves upward and forms continuous distribution in the top of the sandbox. The faster of gas injects, the wider of gas migration will be. The DNAPL infiltration experiment shows that TCE mainly moves downward as the influence of gravity, stopping vertical infiltration when reaching the low permeability lenses because of its failure to overcome the capillary pressure. Then, TCE accumulates on the surface and starts transverse movement. Bypassing the lenses, TCE migrates down again and eventually accumulates at the bottom of the sandbox. The two models of quantification of fluid saturations for water/gas system and water/NAPL system developed in homogenous porous media give comparatively fit results to the observations and can be used to quantify fluid saturations in heterogeneous porous media.

  16. Transmission of Ebola Viruses: What We Know and What We Do Not Know

    PubMed Central

    Moore, Kristine A.; Kelley, Nicholas S.; Brosseau, Lisa M.; Wong, Gary; Murphy, Frederick A.; Peters, Clarence J.; LeDuc, James W.; Russell, Phillip K.; Van Herp, Michel; Kapetshi, Jimmy; Muyembe, Jean-Jacques T.; Ilunga, Benoit Kebela; Strong, James E.; Grolla, Allen; Wolz, Anja; Kargbo, Brima; Kargbo, David K.; Formenty, Pierre; Sanders, David Avram; Kobinger, Gary P.

    2015-01-01

    ABSTRACT Available evidence demonstrates that direct patient contact and contact with infectious body fluids are the primary modes for Ebola virus transmission, but this is based on a limited number of studies. Key areas requiring further study include (i) the role of aerosol transmission (either via large droplets or small particles in the vicinity of source patients), (ii) the role of environmental contamination and fomite transmission, (iii) the degree to which minimally or mildly ill persons transmit infection, (iv) how long clinically relevant infectiousness persists, (v) the role that “superspreading events” may play in driving transmission dynamics, (vi) whether strain differences or repeated serial passage in outbreak settings can impact virus transmission, and (vii) what role sylvatic or domestic animals could play in outbreak propagation, particularly during major epidemics such as the 2013–2015 West Africa situation. In this review, we address what we know and what we do not know about Ebola virus transmission. We also hypothesize that Ebola viruses have the potential to be respiratory pathogens with primary respiratory spread. PMID:25698835

  17. Automatic Mechetronic Wheel Light Device

    DOEpatents

    Khan, Mohammed John Fitzgerald

    2004-09-14

    A wheel lighting device for illuminating a wheel of a vehicle to increase safety and enhance aesthetics. The device produces the appearance of a "ring of light" on a vehicle's wheels as the vehicle moves. The "ring of light" can automatically change in color and/or brightness according to a vehicle's speed, acceleration, jerk, selection of transmission gears, and/or engine speed. The device provides auxiliary indicator lights by producing light in conjunction with a vehicle's turn signals, hazard lights, alarm systems, and etc. The device comprises a combination of mechanical and electronic components and can be placed on the outer or inner surface of a wheel or made integral to a wheel or wheel cover. The device can be configured for all vehicle types, and is electrically powered by a vehicle's electrical system and/or battery.

  18. Automatic control of the preload in adaptive friction drives of chemical production machines

    NASA Astrophysics Data System (ADS)

    Balakin, P. D.

    2017-08-01

    Being based on the principle of providing the systems with adaptation property to the real parameters and operational condition, the energy effective mechanical system constructed on the base of friction gear with automated preload is offered and this allows keeping mechanical efficiency value adequate transforming drive path to in the terms of multimode operation. This is achieved by integrated control loop, operating on the basis of the laws of motion with the energy of the main power flow by changing automatically the kinematic dimension of the section and, hence, the value of preload in the friction contact. The given ratios of forces and deformations in the control loop are required at the stage of conceptual design to determine design dimensions of power transmission elements with new properties.

  19. Distrubtion Tolerant Network Technology Flight Validation Report: DINET

    NASA Technical Reports Server (NTRS)

    Jones, Ross M.

    2009-01-01

    In October and November of 2008, the Jet Propulsion Laboratory installed and tested essential elements of Delay/Disruption Tolerant Networking (DTN) technology on the Deep Impact spacecraft. This experiment, called Deep Impact Network Experiment (DINET), was performed in close cooperation with the EPOXI project which has responsibility for the spacecraft. During DINET some 300 images were transmitted from the JPL nodes to the spacecraft. Then, they were automatically forwarded from the spacecraft back to the JPL nodes, exercising DTN's bundle origination, transmission, acquisition, dynamic route computation, congestion control, prioritization, custody transfer, and automatic retransmission procedures, both on the spacecraft and on the ground, over a period of 27 days. All transmitted bundles were successfully received, without corruption. The DINET experiment demonstrated DTN readiness for operational use in space missions.

  20. Distribution Tolerant Network Technology Flight Validation Report: DINET

    NASA Technical Reports Server (NTRS)

    Jones, Ross M.

    2009-01-01

    In October and November of 2008, the Jet Propulsion Laboratory installed and tested essential elements of Delay/Disruption Tolerant Networking (DTN) technology on the Deep Impact spacecraft. This experiment, called Deep Impact Network Experiment (DINET), was performed in close cooperation with the EPOXI project which has responsibility for the spacecraft. During DINET some 300 images were transmitted from the JPL nodes to the spacecraft. Then, they were automatically forwarded from the spacecraft back to the JPL nodes, exercising DTN's bundle origination, transmission, acquisition, dynamic route computation, congestion control, prioritization, custody transfer, and automatic retransmission procedures, both on the spacecraft and on the ground, over a period of 27 days. All transmitted bundles were successfully received, without corruption. The DINET experiment demonstrated DTN readiness for operational use in space missions.

  1. Calculation of three-dimensional, inviscid, supersonic, steady flows

    NASA Technical Reports Server (NTRS)

    Moretti, G.

    1981-01-01

    A detailed description of a computational program for the evaluation of three dimensional supersonic, inviscid, steady flow past airplanes is presented. Emphasis was put on how a powerful, automatic mapping technique is coupled to the fluid mechanical analysis. Each of the three constituents of the analysis (body geometry, mapping technique, and gas dynamical effects) was carefully coded and described. Results of computations based on sample geometrics and discussions are also presented.

  2. Automated potentiometric electrolyte analysis system. [for use in weightlessness

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The feasibility is demonstrated of utilizing chemical sensing electrode technology as the basis for an automatically-controlled system for blood gas and electrolyte analyses under weightlessness conditions. The specific measurements required were pH, pCO2, sodium, chloride, potassium ions, and ionized calcium. The general electrode theory, and ion activity measurements are described along with the fluid transport package, electronics unit, and controller for the automated potentiometric analysis system.

  3. Automatic temperature adjustment apparatus

    DOEpatents

    Chaplin, James E.

    1985-01-01

    An apparatus for increasing the efficiency of a conventional central space heating system is disclosed. The temperature of a fluid heating medium is adjusted based on a measurement of the external temperature, and a system parameter. The system parameter is periodically modified based on a closed loop process that monitors the operation of the heating system. This closed loop process provides a heating medium temperature value that is very near the optimum for energy efficiency.

  4. Valve technology: A compilation

    NASA Technical Reports Server (NTRS)

    1971-01-01

    A technical compilation on the types, applications and modifications to certain valves is presented. Data cover the following: (1) valves that feature automatic response to stimuli (thermal, electrical, fluid pressure, etc.), (2) modified valves changed by redesign of components to increase initial design effectiveness or give the item versatility beyond its basic design capability, and (3) special purpose valves with limited application as presented, but lending themselves to other uses with minor changes.

  5. Combined Effect of Fluid and Pressure on Middle Ear Function

    PubMed Central

    Dai, Chenkai; Wood, Mark W.; Gan, Rong Z.

    2008-01-01

    In our previous studies, the effects of effusion and pressure on sound transmission were investigated separately. The aim of this study is to investigate the combined effect of fluid and pressure on middle ear function. An otitis media with effusion model was created by injecting saline solution and air pressure simultaneously into the middle ear of human temporal bones. Tympanic membrane displacement in response to 90 dB SPL sound input was measured by a laser vibrometer and the compliance of the middle ear was measured by a tympanometer. The movement of the tympanic membrane at the umbo was reduced up to 17 dB by the combination of fluid and pressure in the middle ear over the auditory frequency range. The fluid and pressure effects on the umbo movement in the fluid-pressure combination are not additive. The combined effect of fluid and pressure on the umbo movement is different compared with that of only fluid or pressure change in the middle ear. Negative pressure in fluid-pressure combination had more effect on middle ear function than positive pressure. Tympanometry can detect the middle ear pressure of the fluid-pressure combination. This study provides quantitative information for analysis of the combined effect of fluid and pressure on tympanic membrane movement. PMID:18162348

  6. Data Capture Technique for High Speed Signaling

    DOEpatents

    Barrett, Wayne Melvin; Chen, Dong; Coteus, Paul William; Gara, Alan Gene; Jackson, Rory; Kopcsay, Gerard Vincent; Nathanson, Ben Jesse; Vranas, Paylos Michael; Takken, Todd E.

    2008-08-26

    A data capture technique for high speed signaling to allow for optimal sampling of an asynchronous data stream. This technique allows for extremely high data rates and does not require that a clock be sent with the data as is done in source synchronous systems. The present invention also provides a hardware mechanism for automatically adjusting transmission delays for optimal two-bit simultaneous bi-directional (SiBiDi) signaling.

  7. BreathBased Monitoring of Pilot Hypoxia - Proof of Concept

    DTIC Science & Technology

    2016-04-21

    vest, and there are no aircraft connections required. Operation is entirely automatic and data visualization is available via a Bluetooth connected...to USB-connected Flash-RAM (storage depends on module size, 32Gb supported). • Bluetooth transmission of data in real time • Automated storage...via an Android tablet (Figure 4). The tablet acquires the data transmitted using Bluetooth by the pilot worn system module and provides a real-time

  8. H-1 Upgrades (4BW/4BN) (H-1 Upgrades)

    DTIC Science & Technology

    2015-12-01

    automatic blade fold of the new composite rotor blades, new performance matched transmissions, a new four-bladed tail rotor and drive system, upgraded...Upgrades December 2015 SAR March 18, 2016 10:59:17 UNCLASSIFIED 4 Col Steven Girard PMA-276 USMC Light/Attack Helicopter Program Executive Officer...attack helicopter is to provide rotary wing close air support, anti-armor, armed escort, armed/visual reconnaissance and fire support coordination

  9. Study of Water Pollution Early Warning Framework Based on Internet of Things

    NASA Astrophysics Data System (ADS)

    Chengfang, H.; Xiao, X.; Dingtao, S.; Bo, C.; Xiongfei, W.

    2016-06-01

    In recent years, with the increasing world environmental pollution happening, sudden water pollution incident has become more and more frequently in China. It has posed a serious threat to water safety of the people living in the water source area. Conventional water pollution monitoring method is manual periodic testing, it maybe miss the best time to find that pollution incident. This paper proposes a water pollution warning framework to change this state. On the basis of the Internet of things, we uses automatic water quality monitoring technology to realize monitoring. We calculate the monitoring data with water pollution model to judge whether the water pollution incident is happen or not. Water pollution warning framework is divided into three layers: terminal as the sensing layer, it with the deployment of the automatic water quality pollution monitoring sensor. The middle layer is the transfer network layer, data information implementation is based on GPRS wireless network transmission. The upper one is the application layer. With these application systems, early warning information of water pollution will realize the high-speed transmission between grassroots units and superior units. The paper finally gives an example that applying this pollution warning framework to water quality monitoring of Beijing, China, it greatly improves the speed of the pollution warning responding of Beijing.

  10. Fault prevention by early stage symptoms detection for automatic vehicle transmission using pattern recognition and curve fitting

    NASA Astrophysics Data System (ADS)

    Balbin, Jessie R.; Cruz, Febus Reidj G.; Abu, Jon Ervin A.; Siño, Carlo G.; Ubaldo, Paolo E.; Zulueta, Christelle Jianne T.

    2017-06-01

    Automobiles have become essential parts of our everyday lives. It can correlate many factors that may affect a vehicle primarily those which may inconvenient or in some cases harm lives or properties. Thus, focusing on detecting an automatic transmission vehicle engine, body and other parts that cause vibration and sound may help prevent car problems using MATLAB. By using sound, vibration, and temperature sensors to detect the defects of the car and with the help of the transmitter and receiver to gather data wirelessly, it is easy to install on to the vehicle. A technique utilized from Toyota Balintawak Philippines that every car is treated as panels(a, b, c, d, and e) 'a' being from the hood until the front wheel of the car and 'e' the rear shield to the back of the car, this was applied on how to properly place the sensors so that precise data could be gathered. Data gathered would be compared to the normal graph taken from the normal status or performance of a vehicle, data that would surpass 50% of the normal graph would be considered that a problem has occurred. The system is designed to prevent car accidents by determining the current status or performance of the vehicle, also keeping people away from harm.

  11. Deep learning approach for the detection and quantification of intraretinal cystoid fluid in multivendor optical coherence tomography.

    PubMed

    Venhuizen, Freerk G; van Ginneken, Bram; Liefers, Bart; van Asten, Freekje; Schreur, Vivian; Fauser, Sascha; Hoyng, Carel; Theelen, Thomas; Sánchez, Clara I

    2018-04-01

    We developed a deep learning algorithm for the automatic segmentation and quantification of intraretinal cystoid fluid (IRC) in spectral domain optical coherence tomography (SD-OCT) volumes independent of the device used for acquisition. A cascade of neural networks was introduced to include prior information on the retinal anatomy, boosting performance significantly. The proposed algorithm approached human performance reaching an overall Dice coefficient of 0.754 ± 0.136 and an intraclass correlation coefficient of 0.936, for the task of IRC segmentation and quantification, respectively. The proposed method allows for fast quantitative IRC volume measurements that can be used to improve patient care, reduce costs, and allow fast and reliable analysis in large population studies.

  12. Deep learning approach for the detection and quantification of intraretinal cystoid fluid in multivendor optical coherence tomography

    PubMed Central

    Venhuizen, Freerk G.; van Ginneken, Bram; Liefers, Bart; van Asten, Freekje; Schreur, Vivian; Fauser, Sascha; Hoyng, Carel; Theelen, Thomas; Sánchez, Clara I.

    2018-01-01

    We developed a deep learning algorithm for the automatic segmentation and quantification of intraretinal cystoid fluid (IRC) in spectral domain optical coherence tomography (SD-OCT) volumes independent of the device used for acquisition. A cascade of neural networks was introduced to include prior information on the retinal anatomy, boosting performance significantly. The proposed algorithm approached human performance reaching an overall Dice coefficient of 0.754 ± 0.136 and an intraclass correlation coefficient of 0.936, for the task of IRC segmentation and quantification, respectively. The proposed method allows for fast quantitative IRC volume measurements that can be used to improve patient care, reduce costs, and allow fast and reliable analysis in large population studies. PMID:29675301

  13. Description of an oral Chagas disease outbreak in Venezuela, including a vertically transmitted case.

    PubMed

    Noya, Belkisyolé Alarcón de; Pérez-Chacón, Gladymar; Díaz-Bello, Zoraida; Dickson, Sonia; Muñoz-Calderón, Arturo; Hernández, Carlos; Pérez, Yadira; Mauriello, Luciano; Moronta, Eyleen

    2017-08-01

    We describe the eleventh major outbreak of foodborne Trypanosoma cruzi transmission in urban Venezuela, including evidence for vertical transmission from the index case to her fetus. After confirming fetal death at 24 weeks of gestation, pregnancy interruption was performed. On direct examination of the amniotic fluid, trypomastigotes were detected. T. cruzi specific-polymerase chain reaction (PCR) also proved positive when examining autopsied fetal organs. Finally, microscopic fetal heart examination revealed amastigote nests. Acute orally transmitted Chagas disease can be life threatening or even fatal for pregnant women and unborn fetuses owing to vertical transmission. There is therefore an urgent need to improve national epidemiologic control measures.

  14. Passive Fetal Heart Monitoring System

    NASA Technical Reports Server (NTRS)

    Zuckerwar, Allan J. (Inventor); Mowrey, Dennis L. (Inventor)

    2003-01-01

    A fetal heart monitoring system and method for detecting and processing acoustic fetal heart signals transmitted by different signal transmission modes. One signal transmission mode, the direct contact mode, occurs in a first frequency band when the fetus is in direct contact with the maternal abdominal wall. Another signal transmission mode, the fluid propagation mode, occurs in a second frequency band when the fetus is in a recessed position with no direct contact with the maternal abdominal wall. The second frequency band is relatively higher than the first frequency band. The fetal heart monitoring system and method detect and process acoustic fetal heart signals that are in the first frequency band and in the second frequency band.

  15. An Experiment of GMPLS-Based Dispersion Compensation Control over In-Field Fibers

    NASA Astrophysics Data System (ADS)

    Seno, Shoichiro; Horiuchi, Eiichi; Yoshida, Sota; Sugihara, Takashi; Onohara, Kiyoshi; Kamei, Misato; Baba, Yoshimasa; Kubo, Kazuo; Mizuochi, Takashi

    As ROADMs (Reconfigurable Optical Add/Drop Multiplexers) are becoming widely used in metro/core networks, distributed control of wavelength paths by extended GMPLS (Generalized MultiProtocol Label Switching) protocols has attracted much attention. For the automatic establishment of an arbitrary wavelength path satisfying dynamic traffic demands over a ROADM or WXC (Wavelength Cross Connect)-based network, precise determination of chromatic dispersion over the path and optimized assignment of dispersion compensation capabilities at related nodes are essential. This paper reports an experiment over in-field fibers where GMPLS-based control was applied for the automatic discovery of chromatic dispersion, path computation, and wavelength path establishment with dynamic adjustment of variable dispersion compensation. The GMPLS-based control scheme, which the authors called GMPLS-Plus, extended GMPLS's distributed control architecture with attributes for automatic discovery, advertisement, and signaling of chromatic dispersion. In this experiment, wavelength paths with distances of 24km and 360km were successfully established and error-free data transmission was verified. The experiment also confirmed path restoration with dynamic compensation adjustment upon fiber failure.

  16. Sexual transmission of human T-cell lymphotropic virus type 1.

    PubMed

    Paiva, Arthur; Casseb, Jorge

    2014-01-01

    Human T-cell lymphotropic virus type 1 (HTLV-1) is endemic in many parts of the world and is primarily transmitted through sexual intercourse or from mother to child. Sexual transmission occurs more efficiently from men to women than women to men and might be enhanced by sexually transmitted diseases that cause ulcers and result in mucosal ruptures, such as syphilis, herpes simplex type 2 (HSV-2), and chancroid. Other sexually transmitted diseases might result in the recruitment of inflammatory cells and could increase the risk of HTLV-1 acquisition and transmission. Additionally, factors that are associated with higher transmission risks include the presence of antibodies against the viral oncoprotein Tax (anti-Tax), a higher proviral load in peripheral blood lymphocytes, and increased cervicovaginal or seminal secretions. Seminal fluid has been reported to increase HTLV replication and transmission, whereas male circumcision and neutralizing antibodies might have a protective effect. Recently, free virions were discovered in plasma, which reveals a possible new mode of HTLV replication. It is unclear how this discovery might affect the routes of HTLV transmission, particularly sexual transmission, because HTLV transmission rates are significantly higher from men to women than women to men.

  17. Machine learning for characterization of insect vector feeding

    USDA-ARS?s Scientific Manuscript database

    Insects that feed by ingesting plant and animal fluids cause devastating damage to humans, livestock, and agriculture worldwide, primarily by transmitting phytopathogenic and zoonotic pathogens. The feeding processes required for successful disease transmission by sucking insects can be recorded by ...

  18. The characterization of exosomes from biological fluids of patients with different types of cancer

    NASA Astrophysics Data System (ADS)

    Yunusova, N. V.; Tamkovich, S. N.; Stakheeva, M. N.; Grigor'eva, A. A.; Somov, A. K.; Tugutova, E. A.; Kolomiets, L. A.; Molchanov, S. V.; Afanas'ev, S. G.; Kakurina, G. V.; Choinzonov, E. L.; Kondakova, I. V.

    2017-09-01

    Exosomes are extracellular membrane structures involved in many physiological and pathological processes including cancerogenesis and metastasis. The purpose of the study was to isolate, identify and analyze the total content of exosomes in biological fluids. The exosomes from the plasma and ascites samples of the patients with ovarian cancer, from the blood plasma of the patients with colorectal and head and neck squamous cell cancer as well as from the blood plasma of healthy donors were characterized using transmission electron microscopy and flow cytometry. The subpopulations of the exosomes in the biological fluids of the patients with different types of cancer were similar, but the protein concentrations of exosomes were different. In this paper we present the methodological approaches allowing us to obtain high quality exosome preparations from biological fluids.

  19. A comparison of the in vitro moisture vapour transmission rate and in vivo fluid-handling capacity of six adhesive foam dressings to a newly reformulated adhesive foam dressing.

    PubMed

    Zehrer, Cindy L; Holm, David; Solfest, Staci E; Walters, Shelley-Ann

    2014-12-01

    This study compared moisture vapour transmission rate (MVTR) and wear time or fluid-handling capacities of six adhesive foam dressings to a reformulated control dressing. Standardised in vitro MVTR methodology and a previously published in vivo artificial wound model (AWM) were used. Mean inverted MVTR for the reformulated dressing was 12 750 g/m(2) /24 hours and was significantly higher than four of the six comparator dressings (P < 0·0001), which ranged from 830 to 11 360 g/m(2) /24 hours. Mean upright MVTR for the reformulated dressing was 980 g/m(2) /24 hours and was significantly different than all of the comparator dressings (P < 0·0001), which ranged from 80 to 1620 g/m(2) /24 hours (three higher/three lower). The reformulated dressing median wear time ranged from 6·1 to >7·0 days, compared with 1·0 to 3·5 days for the comparator dressings (P = 0·0012 to P < 0·0001). The median fluid volume handled ranged from 78·0 to >87 ml compared with 13·0 to 44·5 ml for the comparator dressings (P = 0·0007 to P < 0·001). Interestingly, inverted MVTR did not correspond well to the AWM. These results suggest that marked differences exist between the dressings in terms of both MVTR and wear time or fluid-handling capacity. Furthermore, high inverted MVTR does not necessarily predict longer wear time or fluid-handling capacities of absorbent dressings. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  20. Shedding of Hepatitis C Virus Into the Rectum of HIV-infected Men Who Have Sex With Men.

    PubMed

    Foster, Andrew L; Gaisa, Michael M; Hijdra, Rosanne M; Turner, Samuel S; Morey, Tristan J; Jacobson, Karen B; Fierer, Daniel S

    2017-02-01

    For over a decade we have known of an epidemic of sexually transmitted hepatitis C virus (HCV) infection among human immunodeficiency virus (HIV)-infected men who have sex with men (MSM), but there still remains significant controversy over which bodily fluid(s) are responsible for HCV transmission in these men. We enrolled HIV-infected MSM with recent and chronic HCV infection and quantified HCV from rectal fluid obtained by blind swab. We compared the rectal HCV viral load (VL) with paired blood HCV VL. We found rectal HCV shedding in 20 (47%) of 43 men, only one (2%) of whom had visible bleeding. Detection of rectal HCV shedding was associated with blood VL > 5 log 10 IU/mL (p = .01), and 85% with blood VL > 5 log 10 IU/mL had rectal shedding. The HCV VL of the rectal fluid ranged from 2.6 to 5.5 log 10 IU/mL. Based on the median rectal fluid VL, the surface of an average human penis would be exposed to at least 2,300 IU of HCV for the duration of anal intercourse. This study provides the first direct evidence to our knowledge that a sufficient quantity of HCV is shed into the rectum in HIV-infected men with HCV infection to directly infect an inserted penis or be passed indirectly through fomite-like transmission to the rectum of sex partner. We must develop an appropriate public health campaign to educate MSM about these routes of HCV infection to reverse the HCV epidemic among HIV-infected MSM. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  1. Mechanisms of fine extinction band development in vein quartz: new insights from correlative light and electron microscopy

    NASA Astrophysics Data System (ADS)

    Derez, Tine; Van Der Donck, Tom; Plümper, Oliver; Muchez, Philippe; Pennock, Gill; Drury, Martyn R.; Sintubin, Manuel

    2017-07-01

    Fine extinction bands (FEBs) (also known as deformation lamellae) visible with polarized light microscopy in quartz consist of a range of nanostructures, inferring different formation processes. Previous transmission electron microscopy studies have shown that most FEB nanostructures in naturally deformed quartz are elongated subgrains formed by recovery of dislocation slip bands. Here we show that three types of FEB nanostructure occur in naturally deformed vein quartz from the low-grade metamorphic High-Ardenne slate belt (Belgium). Prismatic oriented FEBs are defined by bands of dislocation walls. Dauphiné twin boundaries present along the FEB boundaries probably formed after FEB formation. In an example of two sub-rhombohedral oriented FEBs, developed as two sets in one grain, the finer FEB set consists of elongated subgrains, similar to FEBs described in previous transmission electron microscopy studies. The second wider FEB set consists of bands with different dislocation density and fluid-inclusion content. The wider FEB set is interpreted as bands with different plastic strain associated with the primary growth banding of the vein quartz grain. The nanometre-scale fluid inclusions are interpreted to have formed from structurally bounded hydroxyl groups that moreover facilitated formation of the elongate subgrains. Larger fluid inclusions aligned along FEBs are explained by fluid-inclusion redistribution along dislocation cores. The prismatic FEB nanostructure and the relation between FEBs and growth bands have not been recognized before, although related structures have been reported in experimentally deformed quartz.

  2. Aerosol Transmission of Filoviruses

    PubMed Central

    Mekibib, Berhanu; Ariën, Kevin K.

    2016-01-01

    Filoviruses have become a worldwide public health concern because of their potential for introductions into non-endemic countries through international travel and the international transport of infected animals or animal products. Since it was first identified in 1976, in the Democratic Republic of Congo (formerly Zaire) and Sudan, the 2013–2015 western African Ebola virus disease (EVD) outbreak is the largest, both by number of cases and geographical extension, and deadliest, recorded so far in medical history. The source of ebolaviruses for human index case(s) in most outbreaks is presumptively associated with handling of bush meat or contact with fruit bats. Transmission among humans occurs easily when a person comes in contact with contaminated body fluids of patients, but our understanding of other transmission routes is still fragmentary. This review deals with the controversial issue of aerosol transmission of filoviruses. PMID:27223296

  3. Ultrasonic ranging and data telemetry system

    DOEpatents

    Brashear, Hugh R.; Blair, Michael S.; Phelps, James E.; Bauer, Martin L.; Nowlin, Charles H.

    1990-01-01

    An ultrasonic ranging and data telemetry system determines a surveyor's position and automatically links it with other simultaneously taken survey data. An ultrasonic and radio frequency (rf) transmitter are carried by the surveyor in a backpack. The surveyor's position is determined by calculations that use the measured transmission times of an airborne ultrasonic pulse transmitted from the backpack to two or more prepositioned ultrasonic transceivers. Once a second, rf communications are used both to synchronize the ultrasonic pulse transmission-time measurements and to transmit other simultaneously taken survey data. The rf communications are interpreted by a portable receiver and microcomputer which are brought to the property site. A video display attached to the computer provides real-time visual monitoring of the survey progress and site coverage.

  4. Advanced Gas Turbine (AGT) powertrain system development for automotive applications

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Progress in the development of a gas turbine engine to improve fuel economy, reduce gaseous emissions and particulate levels, and compatible with a variety of alternate fuels is reported. The powertrain is designated AGT101 and consists of a regenerated single shaft gas turbine engine, a split differential gearbox and a Ford Automatic Overdrive production transmission. The powertrain is controlled by an electronic digital microprocessor and associated actuators, instrumentation, and sensors. Standard automotive accessories are driven by engine power provided by an accessory pad on the gearbox. Component/subsystem development progress is reported in the following areas: compressor, turbine, combustion system, regenerator, gearbox/transmission, structures, ceramic components, foil gas bearing, bearings and seals, rotor dynamics, and controls and accessories.

  5. Lens-free microscopy of cerebrospinal fluid for the laboratory diagnosis of meningitis

    NASA Astrophysics Data System (ADS)

    Delacroix, Robin; Morel, Sophie Nhu An; Hervé, Lionel; Bordy, Thomas; Blandin, Pierre; Dinten, Jean-Marc; Drancourt, Michel; Allier, Cédric

    2018-02-01

    The cytology of the cerebrospinal fluid is traditionally performed by an operator (physician, biologist) by means of a conventional light microscope. The operator visually counts the leukocytes (white blood cells) present in a sample of cerebrospinal fluid (10 μl). It is a tedious job and the result is operator-dependent. Here in order to circumvent the limitations of manual counting, we approach the question of numeration of erythrocytes and leukocytes for the cytological diagnosis of meningitis by means of lens-free microscopy. In a first step, a prospective counts of leukocytes was performed by five different operators using conventional optical microscopy. The visual counting yielded an overall 16.7% misclassification of 72 cerebrospinal fluid specimens in meningitis/non-meningitis categories using a 10 leukocyte/μL cut-off. In a second step, the lens-free microscopy algorithm was adapted step-by-step for counting cerebrospinal fluid cells and discriminating leukocytes from erythrocytes. The optimization of the automatic lens-free counting was based on the prospective analysis of 215 cerebrospinal fluid specimens. The optimized algorithm yielded a 100% sensitivity and a 86% specificity compared to confirmed diagnostics. In a third step, a blind lens-free microscopic analysis of 116 cerebrospinal fluid specimens, including six cases of microbiology confirmed infectious meningitis, yielded a 100% sensitivity and a 79% specificity. Adapted lens-free microscopy is thus emerging as an operator-independent technique for the rapid numeration of leukocytes and erythrocytes in cerebrospinal fluid. In particular, this technique is well suited to the rapid diagnosis of meningitis at point-of-care laboratories.

  6. Implementation of a study to examine the persistence of Ebola virus in the body fluids of Ebola virus disease survivors in Sierra Leone: Methodology and lessons learned

    PubMed Central

    Marrinan, Jaclyn E.; Sesay, Foday R.; Ervin, Elizabeth; Thorson, Anna E.; Xu, Wenbo; Ströher, Ute; Ongpin, Patricia; Abad, Neetu; Ariyarajah, Archchun; Malik, Tasneem; Liu, Hongtu; Ross, Christine; Durski, Kara N.; Gaillard, Philippe; Morgan, Oliver; Formenty, Pierre; Knust, Barbara; Broutet, Nathalie; Sahr, Foday

    2017-01-01

    Background The 2013–2016 West African Ebola virus disease epidemic was unprecedented in terms of the number of cases and survivors. Prior to this epidemic there was limited data available on the persistence of Ebola virus in survivors’ body fluids and the potential risk of transmission, including sexual transmission. Methodology/Principal findings Given the urgent need to determine the persistence of Ebola virus in survivors’ body fluids, an observational cohort study was designed and implemented during the epidemic response operation in Sierra Leone. This publication describes study implementation methodology and the key lessons learned. Challenges encountered during implementation included unforeseen duration of follow-up, complexity of interpreting and communicating laboratory results to survivors, and the urgency of translating research findings into public health practice. Strong community engagement helped rapidly implement the study during the epidemic. The study was conducted in two phases. The first phase was initiated within five months of initial protocol discussions and assessed persistence of Ebola virus in semen of 100 adult men. The second phase assessed the persistence of virus in multiple body fluids (semen or vaginal fluid, menstrual blood, breast milk, and urine, rectal fluid, sweat, saliva, tears), of 120 men and 120 women. Conclusion/Significance Data from this study informed national and global guidelines in real time and demonstrated the need to implement semen testing programs among Ebola virus disease survivors. The lessons learned and study tools developed accelerated the implementation of such programs in Ebola virus disease affected countries, and also informed studies examining persistence of Zika virus. Research is a vital component of the public health response to an epidemic of a poorly characterized disease. Adequate resources should be rapidly made available to answer critical research questions, in order to better inform response efforts. PMID:28892501

  7. Implementation of a study to examine the persistence of Ebola virus in the body fluids of Ebola virus disease survivors in Sierra Leone: Methodology and lessons learned.

    PubMed

    Deen, Gibrilla Fadlu; McDonald, Suzanna L R; Marrinan, Jaclyn E; Sesay, Foday R; Ervin, Elizabeth; Thorson, Anna E; Xu, Wenbo; Ströher, Ute; Ongpin, Patricia; Abad, Neetu; Ariyarajah, Archchun; Malik, Tasneem; Liu, Hongtu; Ross, Christine; Durski, Kara N; Gaillard, Philippe; Morgan, Oliver; Formenty, Pierre; Knust, Barbara; Broutet, Nathalie; Sahr, Foday

    2017-09-01

    The 2013-2016 West African Ebola virus disease epidemic was unprecedented in terms of the number of cases and survivors. Prior to this epidemic there was limited data available on the persistence of Ebola virus in survivors' body fluids and the potential risk of transmission, including sexual transmission. Given the urgent need to determine the persistence of Ebola virus in survivors' body fluids, an observational cohort study was designed and implemented during the epidemic response operation in Sierra Leone. This publication describes study implementation methodology and the key lessons learned. Challenges encountered during implementation included unforeseen duration of follow-up, complexity of interpreting and communicating laboratory results to survivors, and the urgency of translating research findings into public health practice. Strong community engagement helped rapidly implement the study during the epidemic. The study was conducted in two phases. The first phase was initiated within five months of initial protocol discussions and assessed persistence of Ebola virus in semen of 100 adult men. The second phase assessed the persistence of virus in multiple body fluids (semen or vaginal fluid, menstrual blood, breast milk, and urine, rectal fluid, sweat, saliva, tears), of 120 men and 120 women. Data from this study informed national and global guidelines in real time and demonstrated the need to implement semen testing programs among Ebola virus disease survivors. The lessons learned and study tools developed accelerated the implementation of such programs in Ebola virus disease affected countries, and also informed studies examining persistence of Zika virus. Research is a vital component of the public health response to an epidemic of a poorly characterized disease. Adequate resources should be rapidly made available to answer critical research questions, in order to better inform response efforts.

  8. Recent advances in nanosized Mn-Zn ferrite magnetic fluid hyperthermia for cancer treatment.

    PubMed

    Lin, Mei; Huang, Junxing; Sha, Min

    2014-01-01

    This paper reviews the recent research and development of nanosized manganese zinc (Mn-Zn) ferrite magnetic fluid hyperthermia (MFH) for cancer treatment. Mn-Zn ferrite MFH, which has a targeted positioning function that only the temperature of tumor tissue with magnetic nanoparticles can rise, while normal tissue without magnetic nanoparticles is not subject to thermal damage, is a promising therapy for cancer. We introduce briefly the composition and properties of magnetic fluid, the concept of MFH, and features of Mn-Zn ferrite magnetic nanoparticles for MFH such as thermal bystander effect, universality, high specific absorption rate, the targeting effect of small size, uniformity of hyperthermia temperature, and automatic temperature control and constant temperature effect. Next, preparation methods of Mn-Zn ferrite magnetic fluid are discussed, and biocompatibility and biosecurity of Mn-Zn ferrite magnetic fluid are analyzed. Then the applications of nanosized Mn-Zn ferrite MFH in cancer are highlighted, including nanosized Mn-Zn ferrite MFH alone, nanosized Mn-Zn ferrite MFH combined with As2O3 chemotherapy, and nanosized Mn-Zn ferrite MFH combined with radiotherapy. Finally, the combination application of nanosized Mn-Zn ferrite MFH and gene-therapy is conceived, and the challenges and perspectives for the future of nanosized Mn-Zn ferrite MFH for oncotherapy are discussed.

  9. Emergency deployable core catcher

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosewell, M.P.

    An emergency melt down core catcher apparatus for a nuclear reactor having a retrofitable eutectic solute holding vessel connected to a core containment vessel with particle transferring fluid and particles or granules of solid eutectic solute materials contained therein and transferable by automatically operated valve means to transport and position the solid eutectic solute material in a position below the core to catch and react with any partial or complete melt down of the fuel core.

  10. Machine learning for characterization of insect vector feeding

    USDA-ARS?s Scientific Manuscript database

    Insects that feed by ingesting plant and animal fluids cause devastating damage to humans, livestock, and agriculture worldwide, primarily by transmitting pathogens of plants and animals. The feeding processes required for successful pathogen transmission by sucking insects can be recorded by monito...

  11. A reliable transmission protocol for ZigBee-based wireless patient monitoring.

    PubMed

    Chen, Shyr-Kuen; Kao, Tsair; Chan, Chia-Tai; Huang, Chih-Ning; Chiang, Chih-Yen; Lai, Chin-Yu; Tung, Tse-Hua; Wang, Pi-Chung

    2012-01-01

    Patient monitoring systems are gaining their importance as the fast-growing global elderly population increases demands for caretaking. These systems use wireless technologies to transmit vital signs for medical evaluation. In a multihop ZigBee network, the existing systems usually use broadcast or multicast schemes to increase the reliability of signals transmission; however, both the schemes lead to significantly higher network traffic and end-to-end transmission delay. In this paper, we present a reliable transmission protocol based on anycast routing for wireless patient monitoring. Our scheme automatically selects the closest data receiver in an anycast group as a destination to reduce the transmission latency as well as the control overhead. The new protocol also shortens the latency of path recovery by initiating route recovery from the intermediate routers of the original path. On the basis of a reliable transmission scheme, we implement a ZigBee device for fall monitoring, which integrates fall detection, indoor positioning, and ECG monitoring. When the triaxial accelerometer of the device detects a fall, the current position of the patient is transmitted to an emergency center through a ZigBee network. In order to clarify the situation of the fallen patient, 4-s ECG signals are also transmitted. Our transmission scheme ensures the successful transmission of these critical messages. The experimental results show that our scheme is fast and reliable. We also demonstrate that our devices can seamlessly integrate with the next generation technology of wireless wide area network, worldwide interoperability for microwave access, to achieve real-time patient monitoring.

  12. Development status of solid polymer electrolyte water electrolysis for manned spacecraft life support systems

    NASA Technical Reports Server (NTRS)

    Nuttall, L. J.; Titterington, W. A.

    1974-01-01

    Details of the design and system verification test results are presented for a six-man-rated oxygen generation system. The system configuration incorporates components and instrumentation for computer-controlled operation with automatic start-up/shutdown sequencing, fault detection and isolation, and with self-contained sensors and controls for automatic safe emergency shutdown. All fluid and electrical components, sensors, and electronic controls are designed to be easily maintainable under zero-gravity conditions. On-board component spares are utilized in the system concept to sustain long-term operation (six months minimum) in a manned spacecraft application. The system is centered on a 27-cell solid polymer electrolyte water electrolysis module which, combined with the associated system components and controls, forms a total system envelope 40 in. high, 40 in. wide, and 30 in. deep.

  13. The UPSF code: a metaprogramming-based high-performance automatically parallelized plasma simulation framework

    NASA Astrophysics Data System (ADS)

    Gao, Xiatian; Wang, Xiaogang; Jiang, Binhao

    2017-10-01

    UPSF (Universal Plasma Simulation Framework) is a new plasma simulation code designed for maximum flexibility by using edge-cutting techniques supported by C++17 standard. Through use of metaprogramming technique, UPSF provides arbitrary dimensional data structures and methods to support various kinds of plasma simulation models, like, Vlasov, particle in cell (PIC), fluid, Fokker-Planck, and their variants and hybrid methods. Through C++ metaprogramming technique, a single code can be used to arbitrary dimensional systems with no loss of performance. UPSF can also automatically parallelize the distributed data structure and accelerate matrix and tensor operations by BLAS. A three-dimensional particle in cell code is developed based on UPSF. Two test cases, Landau damping and Weibel instability for electrostatic and electromagnetic situation respectively, are presented to show the validation and performance of the UPSF code.

  14. Portable pilot plant for evaluating marine biofouling growth and control in heat exchangers-condensers.

    PubMed

    Casanueva, J F; Sánchez, J; García-Morales, J L; Casanueva-Robles, T; López, J A; Portela, J R; Nebot, E; Sales, D

    2003-01-01

    Biofouling frequently involves a serious impediment to achieving optimum operating conditions in heat exchangers-condensers. The economic coat and energy losses associated with this phenomenon are significant and the environmental impact of biocides must satisfy stringent regulations. A portable pilot plant has been designed in order to carry out in-situ experimental study as biofilm is formed under thermal and hydrodynamically controlled conditions. The pilot plant has an automatic monitoring, control and data acquisition system, which automatically processes data from indirect measure of fouling in terms of increased fluid frictional and heat transfer resistances. A particular method is used and proposed for direct measuring and biofilm characterization. Once we know the actual film thickness, we can calculate the effective thermal conductivity of the layer by using the appropriate heat transfer equations.

  15. Automating the parallel processing of fluid and structural dynamics calculations

    NASA Technical Reports Server (NTRS)

    Arpasi, Dale J.; Cole, Gary L.

    1987-01-01

    The NASA Lewis Research Center is actively involved in the development of expert system technology to assist users in applying parallel processing to computational fluid and structural dynamic analysis. The goal of this effort is to eliminate the necessity for the physical scientist to become a computer scientist in order to effectively use the computer as a research tool. Programming and operating software utilities have previously been developed to solve systems of ordinary nonlinear differential equations on parallel scalar processors. Current efforts are aimed at extending these capabilities to systems of partial differential equations, that describe the complex behavior of fluids and structures within aerospace propulsion systems. This paper presents some important considerations in the redesign, in particular, the need for algorithms and software utilities that can automatically identify data flow patterns in the application program and partition and allocate calculations to the parallel processors. A library-oriented multiprocessing concept for integrating the hardware and software functions is described.

  16. Acoustic Analysis of a Sandwich Non Metallic Panel for Roofs by FEM and Experimental Validation

    NASA Astrophysics Data System (ADS)

    Nieto, P. J. García; del Coz Díaz, J. J.; Vilán, J. A. Vilán; Rabanal, F. P. Alvarez

    2007-12-01

    In this paper we have studied the acoustic behavior of a sandwich non metallic panel for roofs by the finite element method (FEM). This new field of analysis is the fully coupled solution of fluid flows with structural interactions, commonly referred to as fluid-structure interaction (FSI). It is the natural next step to take in the simulation of mechanical systems. The finite element analysis of acoustic-fluid/structure interactions using potential-based or displacement-based Lagrangian formulations is now well established. The non-linearity is due to the `fluid-structure interaction' (FSI) that governs the problem. In a very considerable range of problems the fluid displacement remains small while interaction is substantial. In this category falls our problem, in which the structural motion influence and react with the generation of pressures in two reverberation rooms. The characteristic of acoustic insulation of the panel is calculated basing on the pressures for different frequencies and points in the transmission rooms. Finally the conclusions reached are shown.

  17. An Investigation on the Thermal Effusivity of Nanofluids Containing Al2O3 and CuO Nanoparticles

    PubMed Central

    Noroozi, Monir; Zakaria, Azmi; Moksin, Mohd Maarof; Wahab, Zaidan Abd

    2012-01-01

    The thermal effusivity of Al2O3 and CuO nanofluids in different base fluids, i.e., deionized water, ethylene glycol and olive oil were investigated. The nanofluids, nanoparticles dispersed in base fluids; were prepared by mixing Al2O3, CuO nanopowder and the base fluids using sonication with high-powered pulses to ensure a good uniform dispersion of nanoparticles in the base fluids. The morphology of the particles in the base fluids was investigated by transmission electron microscopy (TEM). In this study, a phase frequency scan of the front pyroelectric configuration technique, with a thermally thick PVDF pyroelectric sensor and sample, was used to measure the thermal effusivity of the prepared nanofluids. The experimental results of the thermal effusivity of the studied solvents (deionized water, ethylene glycol and olive oil) showed good agreement with literature values, and were reduced in the presence of nanoparticles. The thermal effusivity of the nanofluid was found to be particularly sensitive to its base fluid and the type of nanoparticles. PMID:22949865

  18. An investigation on the thermal effusivity of nanofluids Containing Al(2)O(3) and CuO nanoparticles.

    PubMed

    Noroozi, Monir; Zakaria, Azmi; Moksin, Mohd Maarof; Wahab, Zaidan Abd

    2012-01-01

    The thermal effusivity of Al(2)O(3) and CuO nanofluids in different base fluids, i.e., deionized water, ethylene glycol and olive oil were investigated. The nanofluids, nanoparticles dispersed in base fluids; were prepared by mixing Al(2)O(3), CuO nanopowder and the base fluids using sonication with high-powered pulses to ensure a good uniform dispersion of nanoparticles in the base fluids. The morphology of the particles in the base fluids was investigated by transmission electron microscopy (TEM). In this study, a phase frequency scan of the front pyroelectric configuration technique, with a thermally thick PVDF pyroelectric sensor and sample, was used to measure the thermal effusivity of the prepared nanofluids. The experimental results of the thermal effusivity of the studied solvents (deionized water, ethylene glycol and olive oil) showed good agreement with literature values, and were reduced in the presence of nanoparticles. The thermal effusivity of the nanofluid was found to be particularly sensitive to its base fluid and the type of nanoparticles.

  19. Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques.

    PubMed

    Hofmann, Matthias; Pichler, Bernd; Schölkopf, Bernhard; Beyer, Thomas

    2009-03-01

    Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, or morphology templates generated from transmission images. We review and discuss these algorithms and point out challenges for using MR-AC in clinical routine. MR-AC is work-in-progress with potentially promising results from a template-based approach applicable to both brain and torso imaging. While efforts are ongoing in making clinically viable MR-AC fully automatic, further studies are required to realize the potential benefits of MR-based motion compensation and partial volume correction of the PET data.

  20. A review of NASA international programs

    NASA Technical Reports Server (NTRS)

    1979-01-01

    A synoptic overview of NASA's international activities to January 1979 is presented. The cooperating countries and international organizations are identified. Topics covered include (1) cooperative arrangements for ground-based, spaceborne, airborne, rocket-borne, and balloon-borne ventures, joint development, and aeronautical R & D; (2) reimbursable launchings; (3) tracking and data acquisition; and (4) personnel exchanges. International participation in NASA's Earth resources investigations is summarized in the appendix. A list of automatic picture transmission stations is included.

  1. Use of TCSR with Split Windings for Shortening the Spar Cycle Time in 500 kV Lines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matinyan, A. M., E-mail: al-drm@mail.ru; Peshkov, M. V.; Karpov, V. N.

    The arc-fault recharge phenomenon in single-phase automatic reclosure (SPAR) of a line is examined. Abrief description is given of the design of a 500 kV thyristor controlled shunt reactor (TCSR) with split valve-side windings. This type of TCSR is shown to effectively quench a single-phase arc fault in a power transmission line and shortens the SPAR cycle time.

  2. Advanced semi-active engine and transmission mounts: tools for modelling, analysis, design, and tuning

    NASA Astrophysics Data System (ADS)

    Farjoud, Alireza; Taylor, Russell; Schumann, Eric; Schlangen, Timothy

    2014-02-01

    This paper is focused on modelling, design, and testing of semi-active magneto-rheological (MR) engine and transmission mounts used in the automotive industry. The purpose is to develop a complete analysis, synthesis, design, and tuning tool that reduces the need for expensive and time-consuming laboratory and field tests. A detailed mathematical model of such devices is developed using multi-physics modelling techniques for physical systems with various energy domains. The model includes all major features of an MR mount including fluid dynamics, fluid track, elastic components, decoupler, rate-dip, gas-charged chamber, MR fluid rheology, magnetic circuit, electronic driver, and control algorithm. Conventional passive hydraulic mounts can also be studied using the same mathematical model. The model is validated using standard experimental procedures. It is used for design and parametric study of mounts; effects of various geometric and material parameters on dynamic response of mounts can be studied. Additionally, this model can be used to test various control strategies to obtain best vibration isolation performance by tuning control parameters. Another benefit of this work is that nonlinear interactions between sub-components of the mount can be observed and investigated. This is not possible by using simplified linear models currently available.

  3. Terahertz artificial material based on integrated metal-rod-array for phase sensitive fluid detection.

    PubMed

    You, Borwen; Chen, Ching-Yu; Yu, Chin-Ping; Liu, Tze-An; Hattori, Toshiaki; Lu, Ja-Yu

    2017-04-17

    A terahertz artificial material composed of metal rod array is experimentally investigated on its transmission spectral property and successfully incorporated into microfluidics as a miniaturized terahertz waveguide with an extended optical-path-length for label-free fluidic sensing. Theoretical and experimental characterizations of terahertz transmission spectra show that the wave guidance along the metal rod array originates from the resonance of transverse-electric-polarized waves within the metal rod slits. The extended optical path length along three layers of metal-rod-array enables terahertz waves sufficiently overlapping the fluid molecules embedded among the rods, leading to strongly enhanced phase change by approximately one order of magnitude compared with the blank metal-parallel-plate waveguide. Based on the enhanced phase sensitivity, three kinds of colorless liquid analytes, namely, acetone, methanol, and ethanol, with different dipole moments are identified in situ using the metal-rod-array-based microfluidic sensor. The detection limit in molecular amounts of a liquid analyte is experimentally demonstrated to be less than 0.1 mmol, corresponding to 2.7 μmol/mm2. The phase sensitive terahertz metal-rod-array-based sensor potentially has good adaptability in lab-chip technology for various practical applications, such as industrial toxic fluid detection and medical breath inspection.

  4. The effect of hypoxia on neuroeffector transmission in the bovine retractor penis and rat anococcygeus muscles.

    PubMed Central

    Bowman, A.; McGrath, J. C.

    1985-01-01

    The effects of reducing the PO2 of the bathing fluid were studied on non-adrenergic non-cholinergic (NANC) transmission in isolated preparations of the bovine retractor penis muscle, the rat anococcygeus muscle, the guinea-pig taenia caeci and the guinea-pig urinary bladder. Hypoxia rapidly and reversibly impaired NANC transmission in the bovine retractor penis and rat anococcygeus muscles but did not affect transmission in the guinea-pig taenia caeci or bladder, suggesting that different NANC mechanisms are involved. Although neurally-evoked relaxation of the bovine retractor penis was impaired by hypoxia, relaxations produced by vasoactive intestinal peptide, prostaglandin E1, sodium nitroprusside or an inhibitory factor isolated from the bovine retractor penis were unaffected. Since the inhibitory factor is similar to, and may actually be the NANC transmitter, the results suggest that the site of action of hypoxia in impairing transmission is prejunctional at the inhibitory nerve endings. PMID:2994787

  5. Sound transmission through a double-panel construction lined with poroelastic material in the presence of mean flow

    NASA Astrophysics Data System (ADS)

    Zhou, Jie; Bhaskar, Atul; Zhang, Xin

    2013-08-01

    This paper investigates the sound transmission characteristics through a system of double-panel lined with poroelastic material in the core. The panels are surrounded by external and internal fluid media where a uniform external mean flow exists on one side. Biot's theory is used to model the porous material. Three types of constructions—bonded-bonded, bonded-unbonded and unbonded-unbonded—are considered. The effect of Mach number of the external flow on the sound transmission over a wide frequency range in a diffuse sound field is examined. External mean flow is shown to give a modest increase in transmission loss at low frequency, but a significant increase at high frequency. It is brought out that calculations based on static air on the incidence side provide a conservative estimate of sound transmission through the sandwich structure. The acoustic performance of the sandwich panel for different configurations is presented. The effect of curvature of the panel is also brought out by using shallow shell theory.

  6. Person-to-Person Household and Nosocomial Transmission of Andes Hantavirus, Southern Chile, 2011

    PubMed Central

    Martinez-Valdebenito, Constanza; Calvo, Mario; Vial, Cecilia; Mansilla, Rita; Marco, Claudia; Palma, R. Eduardo; Vial, Pablo A.; Valdivieso, Francisca; Mertz, Gregory

    2014-01-01

    Andes hantavirus (ANDV) causes hantavirus cardiopulmonary syndrome in Chile and is the only hantavirus for which person-to-person transmission has been proven. We describe an outbreak of 5 human cases of ANDV infection in which symptoms developed in 2 household contacts and 2 health care workers after exposure to the index case-patient. Results of an epidemiologic investigation and sequence analysis of the virus isolates support person-to-person transmission of ANDV for the 4 secondary case-patients, including nosocomial transmission for the 2 health care workers. Health care personnel who have direct contact with ANDV case-patients or their body fluids should take precautions to prevent transmission of the virus. In addition, because the incubation period of ANDV after environmental exposure is longer than that for person-to-person exposure, all persons exposed to a confirmed ANDV case-patient or with possible environmental exposure to the virus should be monitored for 42 days for clinical symptoms. PMID:25272189

  7. Viscoelastic effect on acoustic band gaps in polymer-fluid composites

    NASA Astrophysics Data System (ADS)

    Merheb, B.; Deymier, P. A.; Muralidharan, K.; Bucay, J.; Jain, M.; Aloshyna-Lesuffleur, M.; Greger, R. W.; Mohanty, S.; Berker, A.

    2009-10-01

    In this paper, we present a theoretical analysis of the propagation of acoustic waves through elastic and viscoelastic two-dimensional phononic crystal structures. Numerical calculations of transmission spectra are conducted by extending the finite-difference-time-domain method to account for linear viscoelastic materials with time-dependent moduli. We study a phononic crystal constituted of a square array of cylindrical air inclusions in a solid viscoelastic matrix. The elastic properties of the solid are those of a silicone rubber. This system exhibits very wide band gaps in its transmission spectrum that extend to frequencies in the audible range of the spectrum. These gaps are characteristic of fluid matrix/air inclusion systems and result from the very large contrast between the longitudinal and transverse speeds of sound in rubber. By treating the matrix as a viscoelastic medium within the standard linear solid (SLS) model, we demonstrate that viscoelasticity impacts the transmission properties of the rubber/air phononic crystal not only by attenuating the transmitted acoustic waves but also by shifting the passing bands frequencies toward lower values. The ranges of frequencies exhibiting attenuation or frequency shift are determined by the value of the relaxation time in the SLS model. We show that viscoelasticity can be used to decrease the frequency of pass bands (and consequently stop bands) in viscoelastic/air phononic crystals.

  8. PROBLEMS OF CYBERNETICS AND SPACE MEDICINE (in Russian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parin, V.V.; Baevskii, R.M.

    1963-01-01

    Problems of cybernetics are discussed with reference to space medicine. The information theory is widely used for solving the problems relevant to radiotelemetric transmission of biological data. Construction of devices for automatic medical control of the condition of the crew of the space ship has a direct bearing to electron diagnostic machines. Mathematical methods and the computing technic are used for analyzing experimental evidence. The theory of automatic regulation was applied for modeling physiological reactions, for developing closed ecological systems, and for solving the problems of driving space ships. The problems bearing on the modifications undergone by the information inmore » the brain are of primary importance for the study of the effect of the space flight conditions upon the efficiency of man, the activity of his nervous system and of his analyzers. (P.C.H.)« less

  9. Development of ATC for High Speed and High Density Commuter Line

    NASA Astrophysics Data System (ADS)

    Okutani, Tamio; Nakamura, Nobuyuki; Araki, Hisato; Irie, Shouji; Osa, Hiroki; Sano, Minoru; Ikeda, Keigo; Ozawa, Hiroyuki

    A new ATC (Automatic Train Control) system has been developed with solutions to realize short train headway by assured braking utilizing digital data transmission via rails; the digital data for the ATP (Automatic Train Protection) function; and to achieve EMC features for both AC and DC sections. The DC section is of the unprecedented DC traction power supply system utilizing IGBT PWM converter at all DC substations. Within the AC section, train traction force is controlled by PWM converter/inverters. The carrier frequencies of the digital data signals and chopping frequency of PWM traction power converters on-board are decided via spectral analysis of noise up to degraded mode cases of equipment. Developed system was equipped to the Tukuba Express Line, new commuter line of Tokyo metropolitan area, and opened since Aug. 2005.

  10. Automatic construction of subject-specific human airway geometry including trifurcations based on a CT-segmented airway skeleton and surface

    PubMed Central

    Miyawaki, Shinjiro; Tawhai, Merryn H.; Hoffman, Eric A.; Wenzel, Sally E.; Lin, Ching-Long

    2016-01-01

    We propose a method to construct three-dimensional airway geometric models based on airway skeletons, or centerlines (CLs). Given a CT-segmented airway skeleton and surface, the proposed CL-based method automatically constructs subject-specific models that contain anatomical information regarding branches, include bifurcations and trifurcations, and extend from the trachea to terminal bronchioles. The resulting model can be anatomically realistic with the assistance of an image-based surface; alternatively a model with an idealized skeleton and/or branch diameters is also possible. This method systematically identifies and classifies trifurcations to successfully construct the models, which also provides the number and type of trifurcations for the analysis of the airways from an anatomical point of view. We applied this method to 16 normal and 16 severe asthmatic subjects using their computed tomography images. The average distance between the surface of the model and the image-based surface was 11% of the average voxel size of the image. The four most frequent locations of trifurcations were the left upper division bronchus, left lower lobar bronchus, right upper lobar bronchus, and right intermediate bronchus. The proposed method automatically constructed accurate subject-specific three-dimensional airway geometric models that contain anatomical information regarding branches using airway skeleton, diameters, and image-based surface geometry. The proposed method can construct (i) geometry automatically for population-based studies, (ii) trifurcations to retain the original airway topology, (iii) geometry that can be used for automatic generation of computational fluid dynamics meshes, and (iv) geometry based only on a skeleton and diameters for idealized branches. PMID:27704229

  11. Advances in traction drive technology

    NASA Technical Reports Server (NTRS)

    Loewenthal, S. H.; Anderson, N. E.; Rohn, D. A.

    1983-01-01

    Traction drives are traced from early uses as main transmissions in automobiles at the turn of the century to modern, high-powered traction drives capable of transmitting hundreds of horsepower. Recent advances in technology are described which enable today's traction drive to be a serious candidate for off-highway vehicles and helicopter applications. Improvements in materials, traction fluids, design techniques, power loss and life prediction methods will be highlighted. Performance characteristics of the Nasvytis fixed-ratio drive are given. Promising future drive applications, such as helicopter main transmissions and servo-control positioning mechanisms are also addressed.

  12. Automated magnification calibration in transmission electron microscopy using Fourier analysis of replica images.

    PubMed

    van der Laak, Jeroen A W M; Dijkman, Henry B P M; Pahlplatz, Martin M M

    2006-03-01

    The magnification factor in transmission electron microscopy is not very precise, hampering for instance quantitative analysis of specimens. Calibration of the magnification is usually performed interactively using replica specimens, containing line or grating patterns with known spacing. In the present study, a procedure is described for automated magnification calibration using digital images of a line replica. This procedure is based on analysis of the power spectrum of Fourier transformed replica images, and is compared to interactive measurement in the same images. Images were used with magnification ranging from 1,000 x to 200,000 x. The automated procedure deviated on average 0.10% from interactive measurements. Especially for catalase replicas, the coefficient of variation of automated measurement was considerably smaller (average 0.28%) compared to that of interactive measurement (average 3.5%). In conclusion, calibration of the magnification in digital images from transmission electron microscopy may be performed automatically, using the procedure presented here, with high precision and accuracy.

  13. Utilizing the Cyberforest live sound system with social media to remotely conduct woodland bird censuses in Central Japan.

    PubMed

    Saito, Kaoru; Nakamura, Kazuhiko; Ueta, Mutsuyuki; Kurosawa, Reiko; Fujiwara, Akio; Kobayashi, Hill Hiroki; Nakayama, Masaya; Toko, Ayako; Nagahama, Kazuyo

    2015-11-01

    We have developed a system that streams and archives live sound from remote areas across Japan via an unmanned automatic camera. The system was used to carry out pilot bird censuses in woodland; this allowed us to examine the use of live sound transmission and the role of social media as a mediator in remote scientific monitoring. The system has been streaming sounds 8 h per day for more than five years. We demonstrated that: (1) the transmission of live sound from a remote woodland could be used effectively to monitor birds in a remote location; (2) the simultaneous involvement of several participants via Internet Relay Chat to listen to live sound transmissions could enhance the accuracy of census data collection; and (3) interactions through Twitter allowed members of the public to engage or help with the remote monitoring of birds and experience inaccessible nature through the use of novel technologies.

  14. Automotive manufacturing assessment system. Volume II: product schedules of engine/drivetrain combinations. Final report Jun 77-Aug 78

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, T. Jr; Cunningham, A.R.; Iannelli, D.A.

    Volume II is part of a four volume set documenting areas of research resulting from the development of the Automotive Manufacturing Assessment System (AMAS) for the DOT/Transportation Systems Center. AMAS was designed to assist in the evaluation of industry's capability to produce fuel efficient vehicles. Engine/driveline changes are the second most important contribution to fuel economy (weight reduction being the first) and are of major importance towards meeting emission standards. Through extensive synthesis of vehicle specifications and other data, chronological presentations were developed to illustrate engines and transmissions in production, engine/transmission and model/engine combinations, and automatic vs. manual transmission availability.more » Also shown are the progression of engine/driveline changes from 1975 through 1978; the correlation of these changes with new vehicle introductions; the restrictions on available drive-train options due to emission requirements; and technological improvements including dieselization, fuel metering, lock-up torque converters, and front-wheel-drive.« less

  15. Dynamic analysis of flexible gear trains/transmissions - An automated approach

    NASA Technical Reports Server (NTRS)

    Amirouche, F. M. L.; Shareef, N. H.; Xie, M.

    1992-01-01

    In this paper an automated algorithmic method is presented for the dynamic analysis of geared trains/transmissions. These are treated as a system of interconnected flexible bodies. The procedure developed explains the switching of constraints with time as a result of the change in the contacting areas at the gear teeth. The elastic behavior of the system is studied through the employment of three-dimensional isoparametric elements having six degrees-of-freedom at each node. The contact between the bodies is assumed at the various nodes, which could be either a line or a plane. The kinematical expressions, together with the equations of motion using Kane's method, strain energy concepts, are presented in a matrix form suitable for computer implementation. The constraint Jacobian matrices are generated automatically based on the contact information between the bodies. The concepts of the relative velocity at the contacting points at the tooth pairs and the subsequent use of the transmission ratios in the analysis is presented.

  16. Analyzing and Detecting Problems in Systems of Systems

    NASA Technical Reports Server (NTRS)

    Lindvall, Mikael; Ackermann, Christopher; Stratton, William C.; Sibol, Deane E.; Godfrey, Sally

    2008-01-01

    Many software systems are evolving complex system of systems (SoS) for which inter-system communication is mission-critical. Evidence indicates that transmission failures and performance issues are not uncommon occurrences. In a NASA-supported Software Assurance Research Program (SARP) project, we are researching a new approach addressing such problems. In this paper, we are presenting an approach for analyzing inter-system communications with the goal to uncover both transmission errors and performance problems. Our approach consists of a visualization and an evaluation component. While the visualization of the observed communication aims to facilitate understanding, the evaluation component automatically checks the conformance of an observed communication (actual) to a desired one (planned). The actual and the planned are represented as sequence diagrams. The evaluation algorithm checks the conformance of the actual to the planned diagram. We have applied our approach to the communication of aerospace systems and were successful in detecting and resolving even subtle and long existing transmission problems.

  17. Acoustic metacages for sound shielding with steady air flow

    NASA Astrophysics Data System (ADS)

    Shen, Chen; Xie, Yangbo; Li, Junfei; Cummer, Steven A.; Jing, Yun

    2018-03-01

    Conventional sound shielding structures typically prevent fluid transport between the exterior and interior. A design of a two-dimensional acoustic metacage with subwavelength thickness which can shield acoustic waves from all directions while allowing steady fluid flow is presented in this paper. The structure is designed based on acoustic gradient-index metasurfaces composed of open channels and shunted Helmholtz resonators. In-plane sound at an arbitrary angle of incidence is reflected due to the strong parallel momentum on the metacage surface, which leads to low sound transmission through the metacage. The performance of the proposed metacage is verified by numerical simulations and measurements on a three-dimensional printed prototype. The acoustic metacage has potential applications in sound insulation where steady fluid flow is necessary or advantageous.

  18. Recommendation of Sensors for Vehicle Transmission Diagnostics

    DTIC Science & Technology

    2012-05-01

    and a pressure switch module form the Control value module. A thermistor is contained within the pressure switch module in order to monitor the sump...fluid temperature. Sensor information is provided to the TCM through various sensors such as throttle position, speed sensor, pressure switch module

  19. Incubation under fluid dynamic conditions markedly improves the structural preservation in vitro of explanted skeletal muscles.

    PubMed

    Carton, Flavia; Calderan, Laura; Malatesta, Manuela

    2017-11-28

    Explanted organs and tissues represent suitable experimental systems mimicking the functional and structural complexity of the living organism, with positive ethical and economic impact on research activities. However, their preservation in culture is generally limited, thus hindering their application as experimental models for biomedical research. In the present study, we investigated the potential of an innovative fluid dynamic culture system to improve the structural preservation in vitro of explanted mouse skeletal muscles (soleus). We used light and transmission electron microscopy to compare the morphological features of muscles maintained either in multiwell plates under conventional conditions or in a bioreactor mimicking the flow of physiological fluids. Our results demonstrate that fluid dynamic conditions markedly slowed the progressive structural deterioration of the muscle tissue occurring during the permanence in the culture medium, prolonging the preservation of some organelles such as mitochondria up to 48 h.

  20. Incubation under fluid dynamic conditions markedly improves the structural preservation in vitro of explanted skeletal muscles

    PubMed Central

    Carton, Flavia; Calderan, Laura; Malatesta, Manuela

    2017-01-01

    Explanted organs and tissues represent suitable experimental systems mimicking the functional and structural complexity of the living organism, with positive ethical and economic impact on research activities. However, their preservation in culture is generally limited, thus hindering their application as experimental models for biomedical research. In the present study, we investigated the potential of an innovative fluid dynamic culture system to improve the structural preservation in vitro of explanted mouse skeletal muscles (soleus). We used light and transmission electron microscopy to compare the morphological features of muscles maintained either in multiwell plates under conventional conditions or in a bioreactor mimicking the flow of physiological fluids. Our results demonstrate that fluid dynamic conditions markedly slowed the progressive structural deterioration of the muscle tissue occurring during the permanence in the culture medium, prolonging the preservation of some organelles such as mitochondria up to 48 h. PMID:29313601

  1. Development of a cloud-based system for remote monitoring of a PVT panel

    NASA Astrophysics Data System (ADS)

    Saraiva, Luis; Alcaso, Adérito; Vieira, Paulo; Ramos, Carlos Figueiredo; Cardoso, Antonio Marques

    2016-10-01

    The paper presents a monitoring system developed for an energy conversion system based on the sun and known as thermophotovoltaic panel (PVT). The project was implemented using two embedded microcontrollers platforms (arduino Leonardo and arduino yún), wireless transmission systems (WI-FI and XBEE) and net computing ,commonly known as cloud (Google cloud). The main objective of the project is to provide remote access and real-time data monitoring (like: electrical current, electrical voltage, input fluid temperature, output fluid temperature, backward fluid temperature, up PV glass temperature, down PV glass temperature, ambient temperature, solar radiation, wind speed, wind direction and fluid mass flow). This project demonstrates the feasibility of using inexpensive microcontroller's platforms and free internet service in theWeb, to support the remote study of renewable energy systems, eliminating the acquisition of dedicated systems typically more expensive and limited in the kind of processing proposed.

  2. Non-fibrous inorganic particles in bronchoalveolar lavage fluid of pottery workers.

    PubMed Central

    Falchi, M; Paoletti, L; Mariotta, S; Giosue, S; Guidi, L; Biondo, L; Scavalli, P; Bisetti, A

    1996-01-01

    AIM: To study the actual exposure of pottery workers to silica particles, as their risk of silicosis is potentially high because of the presence of inhalable crystalline silica particles in the workplace. METHODS: Nine pottery workers underwent bronchoalveolar lavage. The recovered fluid was analysed for cytological and mineralogical content by analytical transmission electron microscopy. The data were compared with those obtained from a control group composed of seven patients with sarcoidosis and six patients with haemoptysis. RESULTS: Cytological results showed a similar profile in exposed workers and controls, whereas in patients with sarcoidosis a lymphocytic alveolitis was found. Microanalysis of the particulate identified the presence of silicates, CRSs, and metals. Pottery workers had higher numbers of total particles and CRSs, and had a higher silicate/metal ratio. In five workers, the presence of zirconium silicate was also detected. Patients with sarcoidosis had the lowest number of particles, and an inverted silicate/metal ratio. CONCLUSION: Microanalysis by transmission electron microscope can provide useful information to assess occupational exposure to dusts. PMID:9038801

  3. Risky traditional practices and prevention of mother-to-child transmission of HIV: the case of Chiota community in Zimbabwe.

    PubMed

    Nyati-Jokomo, Zibusiso; January, James; Ruparanganda, Watch; Chitsike, Inam

    2016-01-01

    The objective of this study was to explore cultural practices that could expose babies to HIV infection during the postnatal period in Chiota community in Zimbabwe. Purposively selected and gender disaggregated members of the community (n = 231) were informants to 23 focus group discussions and 8 semi-structured key-informant interviews. Data were analysed thematically. Emerging themes relating to risky practices were rituals surrounding open fontanelle, toning of child's sexual libido, initiation of sex after childbirth, treatment of eye and ear infections, tongue-tie and pre-mastication. These practices exposed babies to bodily fluids such as saliva, breast milk, vaginal fluids, pre-cum and semen which in turn put the babies at low to high risk of contracting HIV. This paper discusses implications for these risky practices in prevention of mother-to-child transmission of HIV. There is, therefore, need for studies to establish the prevalence of these practices.

  4. Highly sensitive magnetic field sensor based on microfiber coupler with magnetic fluid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, Longfeng; Pu, Shengli, E-mail: shlpu@usst.edu.cn; Tang, Jiali

    2015-05-11

    A kind of magnetic field sensor using a microfiber coupler (MFC) surrounded with magnetic fluid (MF) is proposed and experimentally demonstrated. As the MFC is strongly sensitive to the surrounding refractive index (RI) and MF's RI is sensitive to magnetic field, the magnetic field sensing function of the proposed structure is realized. Interrogation of magnetic field strength is achieved by measuring the dip wavelength shift and transmission loss change of the transmission spectrum. The experimental results show that the sensitivity of the sensor is wavelength-dependent. The maximum sensitivity of 191.8 pm/Oe is achieved at wavelength of around 1537 nm in this work.more » In addition, a sensitivity of −0.037 dB/Oe is achieved by monitoring variation of the fringe visibility. These suggest the potential applications of the proposed structure in tunable all-in-fiber photonic devices such as magneto-optical modulator, filter, and sensing.« less

  5. Evaluation of a deep learning approach for the segmentation of brain tissues and white matter hyperintensities of presumed vascular origin in MRI.

    PubMed

    Moeskops, Pim; de Bresser, Jeroen; Kuijf, Hugo J; Mendrik, Adriënne M; Biessels, Geert Jan; Pluim, Josien P W; Išgum, Ivana

    2018-01-01

    Automatic segmentation of brain tissues and white matter hyperintensities of presumed vascular origin (WMH) in MRI of older patients is widely described in the literature. Although brain abnormalities and motion artefacts are common in this age group, most segmentation methods are not evaluated in a setting that includes these items. In the present study, our tissue segmentation method for brain MRI was extended and evaluated for additional WMH segmentation. Furthermore, our method was evaluated in two large cohorts with a realistic variation in brain abnormalities and motion artefacts. The method uses a multi-scale convolutional neural network with a T 1 -weighted image, a T 2 -weighted fluid attenuated inversion recovery (FLAIR) image and a T 1 -weighted inversion recovery (IR) image as input. The method automatically segments white matter (WM), cortical grey matter (cGM), basal ganglia and thalami (BGT), cerebellum (CB), brain stem (BS), lateral ventricular cerebrospinal fluid (lvCSF), peripheral cerebrospinal fluid (pCSF), and WMH. Our method was evaluated quantitatively with images publicly available from the MRBrainS13 challenge ( n  = 20), quantitatively and qualitatively in relatively healthy older subjects ( n  = 96), and qualitatively in patients from a memory clinic ( n  = 110). The method can accurately segment WMH (Overall Dice coefficient in the MRBrainS13 data of 0.67) without compromising performance for tissue segmentations (Overall Dice coefficients in the MRBrainS13 data of 0.87 for WM, 0.85 for cGM, 0.82 for BGT, 0.93 for CB, 0.92 for BS, 0.93 for lvCSF, 0.76 for pCSF). Furthermore, the automatic WMH volumes showed a high correlation with manual WMH volumes (Spearman's ρ  = 0.83 for relatively healthy older subjects). In both cohorts, our method produced reliable segmentations (as determined by a human observer) in most images (relatively healthy/memory clinic: tissues 88%/77% reliable, WMH 85%/84% reliable) despite various degrees of brain abnormalities and motion artefacts. In conclusion, this study shows that a convolutional neural network-based segmentation method can accurately segment brain tissues and WMH in MR images of older patients with varying degrees of brain abnormalities and motion artefacts.

  6. High speed flow cytometer droplet formation system and method

    DOEpatents

    Van den Engh, Ger

    2000-01-01

    A droplet forming flow cytometer system allows high speed processing without the need for high oscillator drive powers through the inclusion of an oscillator or piezoelectric crystal such as within the nozzle volume or otherwise unidirectionally coupled to the sheath fluid. The nozzle container continuously converges so as to amplify unidirectional oscillations which are transmitted as pressure waves through the nozzle volume to the nozzle exit so as to form droplets from the fluid jet. The oscillator is directionally isolated so as to avoid moving the entire nozzle container so as to create only pressure waves within the sheath fluid. A variation in substance concentration is achieved through a movable substance introduction port which is positioned within a convergence zone to vary the relative concentration of substance to sheath fluid while still maintaining optimal laminar flow conditions. This variation may be automatically controlled through a sensor and controller configuration. A replaceable tip design is also provided whereby the ceramic nozzle tip is positioned within an edge insert in the nozzle body so as to smoothly transition from nozzle body to nozzle tip. The nozzle tip is sealed against its outer surface to the nozzle body so it may be removable for cleaning or replacement.

  7. PFMCal : Photonic force microscopy calibration extended for its application in high-frequency microrheology

    NASA Astrophysics Data System (ADS)

    Butykai, A.; Domínguez-García, P.; Mor, F. M.; Gaál, R.; Forró, L.; Jeney, S.

    2017-11-01

    The present document is an update of the previously published MatLab code for the calibration of optical tweezers in the high-resolution detection of the Brownian motion of non-spherical probes [1]. In this instance, an alternative version of the original code, based on the same physical theory [2], but focused on the automation of the calibration of measurements using spherical probes, is outlined. The new added code is useful for high-frequency microrheology studies, where the probe radius is known but the viscosity of the surrounding fluid maybe not. This extended calibration methodology is automatic, without the need of a user's interface. A code for calibration by means of thermal noise analysis [3] is also included; this is a method that can be applied when using viscoelastic fluids if the trap stiffness is previously estimated [4]. The new code can be executed in MatLab and using GNU Octave. Program Files doi:http://dx.doi.org/10.17632/s59f3gz729.1 Licensing provisions: GPLv3 Programming language: MatLab 2016a (MathWorks Inc.) and GNU Octave 4.0 Operating system: Linux and Windows. Supplementary material: A new document README.pdf includes basic running instructions for the new code. Journal reference of previous version: Computer Physics Communications, 196 (2015) 599 Does the new version supersede the previous version?: No. It adds alternative but compatible code while providing similar calibration factors. Nature of problem (approx. 50-250 words): The original code uses a MatLab-provided user's interface, which is not available in GNU Octave, and cannot be used outside of a proprietary software as MatLab. Besides, the process of calibration when using spherical probes needs an automatic method when calibrating big amounts of different data focused to microrheology. Solution method (approx. 50-250 words): The new code can be executed in the latest version of MatLab and using GNU Octave, a free and open-source alternative to MatLab. This code generates an automatic calibration process which requires only to write the input data in the main script. Additionally, we include a calibration method based on thermal noise statistics, which can be used with viscoelastic fluids if the trap stiffness is previously estimated. Reasons for the new version: This version extends the functionality of PFMCal for the particular case of spherical probes and unknown fluid viscosities. The extended code is automatic, works in different operating systems and it is compatible with GNU Octave. Summary of revisions: The original MatLab program in the previous version, which is executed by PFMCal.m, is not changed. Here, we have added two additional main archives named PFMCal_auto.m and PFMCal_histo.m, which implement automatic calculations of the calibration process and calibration through Boltzmann statistics, respectively. The process of calibration using this code for spherical beads is described in the README.pdf file provided in the new code submission. Here, we obtain different calibration factors, β (given in μm/V), according to [2], related to two statistical quantities: the mean-squared displacement (MSD), βMSD, and the velocity autocorrelation function (VAF), βVAF. Using that methodology, the trap stiffness, k, and the zero-shear viscosity of the fluid, η, can be calculated if the value of the particle's radius, a, is previously known. For comparison, we include in the extended code the method of calibration using the corner frequency of the power-spectral density (PSD) [5], providing a calibration factor βPSD. Besides, with the prior estimation of the trap stiffness, along with the known value of the particle's radius, we can use thermal noise statistics to obtain calibration factors, β, according to the quadratic form of the optical potential, βE, and related to the Gaussian distribution of the bead's positions, βσ2. This method has been demonstrated to be applicable to the calibration of optical tweezers when using non-Newtonian viscoelastic polymeric liquids [4]. An example of the results using this calibration process is summarized in Table 1. Using the data provided in the new code submission, for water and acetone fluids, we calculate all the calibration factors by using the original PFMCal.m and by the new non-GUI code PFMCal_auto.m and PFMCal_histo.m. Regarding the new code, PFMCal_auto.m returns η, k, βMSD, βVAF and βPSD, while PFMCal_histo.m provides βσ2 and βE. Table 1 shows how we obtain the expected viscosity of the two fluids at this temperature and how the different methods provide good agreement between trap stiffnesses and calibration factors. Additional comments including Restrictions and Unusual features (approx. 50-250 words): The original code, PFMCal.m, runs under MatLab using the Statistics Toolbox. The extended code, PFMCal_auto.m and PFMCal_histo.m, can be executed without modification using MatLab or GNU Octave. The code has been tested in Linux and Windows operating systems.

  8. Computational performance of Free Mesh Method applied to continuum mechanics problems

    PubMed Central

    YAGAWA, Genki

    2011-01-01

    The free mesh method (FMM) is a kind of the meshless methods intended for particle-like finite element analysis of problems that are difficult to handle using global mesh generation, or a node-based finite element method that employs a local mesh generation technique and a node-by-node algorithm. The aim of the present paper is to review some unique numerical solutions of fluid and solid mechanics by employing FMM as well as the Enriched Free Mesh Method (EFMM), which is a new version of FMM, including compressible flow and sounding mechanism in air-reed instruments as applications to fluid mechanics, and automatic remeshing for slow crack growth, dynamic behavior of solid as well as large-scale Eigen-frequency of engine block as applications to solid mechanics. PMID:21558753

  9. Tire with Self-Repairing Mechanism

    NASA Astrophysics Data System (ADS)

    Nagaya, Kosuke; Ikai, Sigeo; Chiba, Manabu; Chao, Xujing

    A new type of tire is presented, in which there is no air leakage when nails puncture the tire. The broken part is repaired automatically by a self-repairing mechanism. The self-repairing unit consists of two rubber sheets with internal lattices. Polymer particles, which expand their volume on adding water, are inserted into the lattices. The unit is adhered to the inside wall of the tire. Coolant fluid diluted with water is introduced to the polymers uniformly. In this system, the polymer particles expand with water-diluted coolant fluid, and become gel. Hence, they stop air leakages in the tire. Fundamental experiments are performed, and optimum conditions are found. This technique is also applied to real tires, and it is ascertained that there is no air leakage when the tire is punctured by nails.

  10. Electric Motor Thermal Management R&D. Annual Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bennion, Kevin

    With the push to reduce component volumes, lower costs, and reduce weight without sacrificing performance or reliability, the challenges associated with thermal management increase for power electronics and electric motors. Thermal management for electric motors will become more important as the automotive industry continues the transition to more electrically dominant vehicle propulsion systems. The transition to more electrically dominant propulsion systems leads to higher-power duty cycles for electric drive systems. Thermal constraints place significant limitations on how electric motors ultimately perform, and as thermal management improves, there will be a direct trade-off between motor performance, efficiency, cost, and the sizingmore » of electric motors to operate within the thermal constraints. The goal of this research project is to support broad industry demand for data, analysis methods, and experimental techniques to improve and better understand motor thermal management. Work in FY15 focused on two areas related to motor thermal management: passive thermal performance and active convective cooling. Passive thermal performance emphasized the thermal impact of materials and thermal interfaces among materials within an assembled motor. The research tasks supported the publication of test methods and data for thermal contact resistances and direction-dependent thermal conductivity within an electric motor. Active convective cooling focused on measuring convective heat-transfer coefficients using automatic transmission fluid (ATF). Data for average convective heat transfer coefficients for direct impingement of ATF jets was published. Also, experimental hardware for mapping local-scale and stator-scale convective heat transfer coefficients for ATF jet impingement were developed.« less

  11. Power transmission device for four wheel drive vehicle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iwatsuki, T.; Kawamoto, M.; Kano, T.

    This patent describes a power transmission device with an improved differential motion limiting mechanism for a four wheel drive vehicle having automatic transmission means, front wheel differential gear means, differential motion limiting means and transfer unit means including center differential gear means, comprising: a first gear mount casing having a gear adapted to mesh with an output of a transmission; a differential motion limiting device arranged together with a front wheel differential gear in the first gear mount casing. The front wheel differential gear having a first diff-carrier and the differential motion limiting device comprising a hydraulic friction clutch formore » engaging and disengaging the first gear mount casing with the first diff-carrier of the front wheel differential gear; a second gear mount casing disposed coaxially with respect to the first gear mount casing; and a transfer unit including a center differential gear arranged in the second gear mount casing, the center differential gear comprising a second diff-carrier coupled with the first gear mount casing, a first side gear coupled with the first diff-carrier of the front wheel differential gear, and a second side gear coupled with the second gear mount casing for transmitting power to the rear wheels.« less

  12. SPIM-fluid: open source light-sheet based platform for high-throughput imaging

    PubMed Central

    Gualda, Emilio J.; Pereira, Hugo; Vale, Tiago; Estrada, Marta Falcão; Brito, Catarina; Moreno, Nuno

    2015-01-01

    Light sheet fluorescence microscopy has recently emerged as the technique of choice for obtaining high quality 3D images of whole organisms/embryos with low photodamage and fast acquisition rates. Here we present an open source unified implementation based on Arduino and Micromanager, which is capable of operating Light Sheet Microscopes for automatized 3D high-throughput imaging on three-dimensional cell cultures and model organisms like zebrafish, oriented to massive drug screening. PMID:26601007

  13. Steady-State Computation of Constant Rotational Rate Dynamic Stability Derivatives

    NASA Technical Reports Server (NTRS)

    Park, Michael A.; Green, Lawrence L.

    2000-01-01

    Dynamic stability derivatives are essential to predicting the open and closed loop performance, stability, and controllability of aircraft. Computational determination of constant-rate dynamic stability derivatives (derivatives of aircraft forces and moments with respect to constant rotational rates) is currently performed indirectly with finite differencing of multiple time-accurate computational fluid dynamics solutions. Typical time-accurate solutions require excessive amounts of computational time to complete. Formulating Navier-Stokes (N-S) equations in a rotating noninertial reference frame and applying an automatic differentiation tool to the modified code has the potential for directly computing these derivatives with a single, much faster steady-state calculation. The ability to rapidly determine static and dynamic stability derivatives by computational methods can benefit multidisciplinary design methodologies and reduce dependency on wind tunnel measurements. The CFL3D thin-layer N-S computational fluid dynamics code was modified for this study to allow calculations on complex three-dimensional configurations with constant rotation rate components in all three axes. These CFL3D modifications also have direct application to rotorcraft and turbomachinery analyses. The modified CFL3D steady-state calculation is a new capability that showed excellent agreement with results calculated by a similar formulation. The application of automatic differentiation to CFL3D allows the static stability and body-axis rate derivatives to be calculated quickly and exactly.

  14. Advanced Gas Turbine (AGT) powertrain system development for automotive applications

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Preliminary layouts were made for the exhaust system, air induction system, and battery installation. Points of interference were identified and resolved by altering either the vehicle or engine designs. An engine general arrangement evolved to meet the vehicle engine compartment constraints while minimizing the duct pressure losses and the heat rejection. A power transfer system (between gasifier and power turbines) was developed to maintain nearly constant temperatures throughout the entire range of engine operation. An advanced four speed automatic transmission was selected to be used with the engine. Performance calculations show improvements in component efficiencies and an increase in fuel economy. A single stage centrifugal compressor design was completed and released for procurement. Gasifier turbine, power turbine, combustor, generator, secondary systems, materials, controls, and transmission development are reported.

  15. New developments in electron microscopy for serial image acquisition of neuronal profiles.

    PubMed

    Kubota, Yoshiyuki

    2015-02-01

    Recent developments in electron microscopy largely automate the continuous acquisition of serial electron micrographs (EMGs), previously achieved by laborious manual serial ultrathin sectioning using an ultramicrotome and ultrastructural image capture process with transmission electron microscopy. The new systems cut thin sections and capture serial EMGs automatically, allowing for acquisition of large data sets in a reasonably short time. The new methods are focused ion beam/scanning electron microscopy, ultramicrotome/serial block-face scanning electron microscopy, automated tape-collection ultramicrotome/scanning electron microscopy and transmission electron microscope camera array. In this review, their positive and negative aspects are discussed. © The Author 2015. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Vibration Propagation of Gear Dynamics in a Gear-Bearing-Housing System Using Mathematical Modeling and Finite Element Analysis

    NASA Technical Reports Server (NTRS)

    Parker, Robert G.; Guo, Yi; Eritenel, Tugan; Ericson, Tristan M.

    2012-01-01

    Vibration and noise caused by gear dynamics at the meshing teeth propagate through power transmission components to the surrounding environment. This study is devoted to developing computational tools to investigate the vibro-acoustic propagation of gear dynamics through a gearbox using different bearings. Detailed finite element/contact mechanics and boundary element models of the gear/bearing/housing system are established to compute the system vibration and noise propagation. Both vibration and acoustic models are validated by experiments including the vibration modal testing and sound field measurements. The effectiveness of each bearing type to disrupt vibration propagation is speed-dependent. Housing plays an important role in noise radiation .It, however, has limited effects on gear dynamics. Bearings are critical components in drivetrains. Accurate modeling of rolling element bearings is essential to assess vibration and noise of drivetrain systems. This study also seeks to fully describe the vibro-acoustic propagation of gear dynamics through a power-transmission system using rolling element and fluid film wave bearings. Fluid film wave bearings, which have higher damping than rolling element bearings, could offer an energy dissipation mechanism that reduces the gearbox noise. The effectiveness of each bearing type to disrupt vibration propagation in explored using multi-body computational models. These models include gears, shafts, rolling element and fluid film wave bearings, and the housing. Radiated noise is mapped from the gearbox surface to surrounding environment. The effectiveness of rolling element and fluid film wave bearings in breaking the vibro-acoustic propagation path from the gear to the housing is investigated.

  17. Development and characterization of crosslinked hyaluronic acid polymeric films for use in coating processes.

    PubMed

    Sgorla, Débora; Almeida, Andreia; Azevedo, Claudia; Bunhak, Ÿlcio Jose; Sarmento, Bruno; Cavalcanti, Osvaldo Albuquerque

    2016-09-10

    The aim of this work was to develop and characterize new hyaluronic acid-based responsive materials for film coating of solid dosage forms. Crosslinking of hyaluronic acid with trisodium trimetaphosphate was performed under controlled alkaline aqueous environment. The films were produced through casting process by mixing crosslinked or bare biopolymer in aqueous dispersion of ethylcellulose, at different proportions. Films were further characterized regarding morphology by scanning electron microscopy, robustness by permeation to water vapor transmission, and ability to hydrate in simulated gastric and intestinal physiological fluids. The safety and biocompatibility of films were assessed against Caco-2 and HT29-MTX intestinal cells. The permeation to water vapor transmission was favored by increasing hyaluronic acid content in the final formulation. When in simulated gastric fluid, films exhibited lower hydration ability compared to more extensive hydration in simulated intestinal fluids. Simultaneously, in simulated intestinal fluids, films partially lost weight, revealing ability for preventing drug release at gastric pH, but tailoring the release at higher intestinal pH. The physiochemical characterization suggests thermal stability of films and physical interaction between compounds of formulation. Lastly, cytotoxicity tests demonstrated that films and individual components of the formulations, when incubated for 4h, were safe for intestinal cells Overall, these evidences suggest that hyaluronic acid-based responsive films, applied as coating material of oral solid dosage forms, can prevent the premature release of drugs in harsh stomach conditions, but control the release it in gastrointestinal tract distal portion, assuring safety to intestinal mucosa. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Neurobrucellosis in Stranded Dolphins, Costa Rica

    PubMed Central

    Hernández-Mora, Gabriela; González-Barrientos, Rocío; Morales, Juan-Alberto; Chaves-Olarte, Esteban; Guzmán-Verri, Caterina; Baquero-Calvo, Elías; De-Miguel, María-Jesús; Marín, Clara-María; Blasco, José-María

    2008-01-01

    Ten striped dolphins, Stenella coeruleoalba, stranded along the Costa Rican Pacific coast, had meningoencephalitis and antibodies against Brucella spp. Brucella ceti was isolated from cerebrospinal fluid of 6 dolphins and 1 fetus. S. coeruleoalba constitutes a highly susceptible host and a potential reservoir for B. ceti transmission. PMID:18760012

  19. 30 CFR 715.19 - Use of explosives.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... wells, petroleum or gas-storage facilities, municipal water-storage facilities, fluid-transmission pipelines, gas or oil-collection lines, or water and sewage lines; and (C) 500 feet of an underground mine... explosive materials shall— (i) Have demonstrated a knowledge of, and a willingness to comply with, safety...

  20. Characterizing Mechanical and Flow Properties using Injection Falloff Tests, March 28, 2011

    EPA Pesticide Factsheets

    This presentation asserts that Injection Fall-off Testing is an efficient way to derive in-situ information on most rock types, after-closure analysis can derive rock transmissibility and pore fluid pressure, and this is used to assist in the HF process.

  1. Effect of External Pressure and Catheter Gauge on Flow Rate, Kinetic Energy, and Endothelial Injury During Intravenous Fluid Administration in a Rabbit Model.

    PubMed

    Hu, Mei-Hua; Chan, Wei-Hung; Chen, Yao-Chang; Cherng, Chen-Hwan; Lin, Chih-Kung; Tsai, Chien-Sung; Chou, Yu-Ching; Huang, Go-Shine

    2016-01-01

    The effects of intravenous (IV) catheter gauge and pressurization of IV fluid (IVF) bags on fluid flow rate have been studied. However, the pressure needed to achieve a flow rate equivalent to that of a 16 gauge (G) catheter through smaller G catheters and the potential for endothelial damage from the increased kinetic energy produced by higher pressurization are unclear. Constant pressure on an IVF bag was maintained by an automatic adjustable pneumatic pressure regulator of our own design. Fluids running through 16 G, 18 G, 20 G, and 22 G catheters were assessed while using IV bag pressurization to achieve the flow rate equivalent to that of a 16 G catheter. We assessed flow rates, kinetic energy, and flow injury to rabbit inferior vena cava endothelium. By applying sufficient external constant pressure to an IVF bag, all fluids could be run through smaller (G) catheters at the flow rate in a 16 G catheter. However, the kinetic energy increased significantly as the catheter G increased. Damage to the venous endothelium was negligible or minimal/patchy cell loss. We designed a new rapid infusion system, which provides a constant pressure that compresses the fluid volume until it is free from visible residual fluid. When large-bore venous access cannot be obtained, multiple smaller catheters, external pressure, or both should be considered. However, caution should be exercised when fluid pressurized to reach a flow rate equivalent to that in a 16 G catheter is run through a smaller G catheter because of the profound increase in kinetic energy that can lead to venous endothelium injury.

  2. Self-induced seismicity due to fluid circulation along faults

    NASA Astrophysics Data System (ADS)

    Aochi, Hideo; Poisson, Blanche; Toussaint, Renaud; Rachez, Xavier; Schmittbuhl, Jean

    2014-03-01

    In this paper, we develop a system of equations describing fluid migration, fault rheology, fault thickness evolution and shear rupture during a seismic cycle, triggered either by tectonic loading or by fluid injection. Assuming that the phenomena predominantly take place on a single fault described as a finite permeable zone of variable width, we are able to project the equations within the volumetric fault core onto the 2-D fault interface. From the basis of this `fault lubrication approximation', we simulate the evolution of seismicity when fluid is injected at one point along the fault to model-induced seismicity during an injection test in a borehole that intercepts the fault. We perform several parametric studies to understand the basic behaviour of the system. Fluid transmissivity and fault rheology are key elements. The simulated seismicity generally tends to rapidly evolve after triggering, independently of the injection history and end when the stationary path of fluid flow is established at the outer boundary of the model. This self-induced seismicity takes place in the case where shear rupturing on a planar fault becomes dominant over the fluid migration process. On the contrary, if healing processes take place, so that the fluid mass is trapped along the fault, rupturing occurs continuously during the injection period. Seismicity and fluid migration are strongly influenced by the injection rate and the heterogeneity.

  3. Results of the Second U.S. Manned Orbital Space Flight

    DTIC Science & Technology

    1962-05-24

    accomplish 11F voice transmission to the range of approximately 250 miles. Both the ground were unsuccessful. Thc reason for the SARAH beacon and UHF...exposures taken 0 .iquid o 0 0 of the horizon. The .11IT photographic study Front view Front view is discussed, and a sample plhotograplh is shown...beyond from each tracking station automatically in the meaningful limits of horizon-to-horizon the core storage of the computers. Two IBM track. The

  4. Army Staff Automated Administrative Support System (ARSTADS) Report. Phase I. Volume II.

    DTIC Science & Technology

    1980-07-01

    requirements to transmit data with short fuse. This requirement varies from 1-6 times daily throughout the agency. Media used for transmission varies from...material automatically onto magnetic media . (1) Advantages. (a) Eliminates need for second or more typings of material. (b) Can be extremely cost...reduced and other methods of storage media will be possible. VI-1 LOmni (App 6 Contd) B. ZXJXM: Offices are over crowded with record storage containers

  5. Airborne electronically steerable phased array. [steerable antennas - systems analysis

    NASA Technical Reports Server (NTRS)

    Coats, R.

    1975-01-01

    Results of a study directed to the design of a lightweight high-gain, spaceborne communications array are presented. The array includes simultaneous transmission and receiving, automatic acquisition and tracking of a signal within a 60-degree cone from the array normal, and provides for independent forming of the transmit and receive beams. Application for this array is the space shuttle, space station, or any of the advanced manned (or unmanned) orbital vehicles. Performance specifications are also given.

  6. Fuzzy logic controllers: A knowledge-based system perspective

    NASA Technical Reports Server (NTRS)

    Bonissone, Piero P.

    1993-01-01

    Over the last few years we have seen an increasing number of applications of Fuzzy Logic Controllers. These applications range from the development of auto-focus cameras, to the control of subway trains, cranes, automobile subsystems (automatic transmissions), domestic appliances, and various consumer electronic products. In summary, we consider a Fuzzy Logic Controller to be a high level language with its local semantics, interpreter, and compiler, which enables us to quickly synthesize non-linear controllers for dynamic systems.

  7. Feasibility study for the Swaziland/Mozambique interconnector. Final report. Export trade information

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-11-01

    This study, conducted by Black & Veatch, was funded by the U.S. Trade and Development Agency. The report, produced for the Ministry of National Resources, Energy and Environment (MNRE) of Swaziland, determines the least cost capacity expansion option to meet the future power demand and system reliability criteria of Swaziland, with particular emphasis on the proposed interconnector between Swaziland and Mozambique. Volume 2, the Final Report, contains the following sections: (1.0) Introduction; (2.0) Review of SEB Power System; (3.0) SEB Load Forecast and Review; (4.0) SEB Load Forecast Revision; (5.0) The SEB Need for Power; (6.0) SEB System Development Planmore » Review; (7.0) Southern Mozambique EdM power System Review; (8.0) Southern Mozambique EdM Energy and Demand; (9.0) Supply Side Capacity Options for Swaziland and Mozambique; (10.0) SEB Expansion Plan Development; (11.0) EdM Expansion Plan Development; (12.0) Cost Sharing of the Interconnector; (13.0) Enviroinmental Evaluation of Interconnector Options; (14.0) Generation/Transmission Trade Offs; (15.0) Draft Interconnection Agreement and Contract Packages; (16.0) Transmission System Study; (17.0) Automatic General Control; (18.0) Automatic Startup and Shutdown of Hydro Electric Power Plants; (19.0) Communications and Metering; (20.0) Conclusions and Recommendations; Appendix A: Demand Side Management Primer; Appendix B. PURPA and Avoided Cost Calculations.« less

  8. Wide tracking range, auto ranging, low jitter phase lock loop for swept and fixed frequency systems

    DOEpatents

    Kerner, Thomas M.

    2001-01-01

    The present invention provides a wide tracking range phase locked loop (PLL) circuit that achieves minimal jitter in a recovered clock signal, regardless of the source of the jitter (i.e. whether it is in the source or the transmission media). The present invention PLL has automatic harmonic lockout detection circuitry via a novel lock and seek control logic in electrical communication with a programmable frequency discriminator and a code balance detector. (The frequency discriminator enables preset of a frequency window of upper and lower frequency limits to derive a programmable range within which signal acquisition is effected. The discriminator works in combination with the code balance detector circuit to minimize the sensitivity of the PLL circuit to random data in the data stream). In addition, the combination of a differential loop integrator with the lock and seek control logic obviates a code preamble and guarantees signal acquisition without harmonic lockup. An adaptive cable equalizer is desirably used in combination with the present invention PLL to recover encoded transmissions containing a clock and/or data. The equalizer automatically adapts to equalize short haul cable lengths of coaxial and twisted pair cables or wires and provides superior jitter performance itself. The combination of the equalizer with the present invention PLL is desirable in that such combination permits the use of short haul wires without significant jitter.

  9. Lock-up control system for an automatic transmission

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Higashi, H.; Yashiki, S.; Waki, K.

    A lock-up control system is described for an automatic transmission including a torque converter coupled with the output portion on an engine, and a power transmitting gear arrangement coupled with the output portion of the torque converter and controlled to vary the transmitting gear ratio therein by gear ratio control means in accordance with a shifting up or down command supplied to the latter. A lock-up clutch is provided for locking up the output portion of the torque converter to the output portion of the engine. The lock-up control system comprises: lock-up operation control means for controlling the lock-up clutchmore » to be in its operative state and in its inoperative state selectively, and for causing the lock-up clutch to be in the inoperative state thereof when the gear ratio control means performs the control with the shifting up or down command, and lock-up command means for preventing the lock-up operation control means from causing the lock-up clutch to be in the inoperative state thereof until a predetermined reductive variation in the speed of the output portion of the torque converter arises after the shifting up command is supplied to the gear ratio control means under the condition in which the lock-up clutch is in operation to hold a lock-up state.« less

  10. Automatic identification and location technology of glass insulator self-shattering

    NASA Astrophysics Data System (ADS)

    Huang, Xinbo; Zhang, Huiying; Zhang, Ye

    2017-11-01

    The insulator of transmission lines is one of the most important infrastructures, which is vital to ensure the safe operation of transmission lines under complex and harsh operating conditions. The glass insulator often self-shatters but the available identification methods are inefficient and unreliable. Then, an automatic identification and localization technology of self-shattered glass insulators is proposed, which consists of the cameras installed on the tower video monitoring devices or the unmanned aerial vehicles, the 4G/OPGW network, and the monitoring center, where the identification and localization algorithm is embedded into the expert software. First, the images of insulators are captured by cameras, which are processed to identify the region of insulator string by the presented identification algorithm of insulator string. Second, according to the characteristics of the insulator string image, a mathematical model of the insulator string is established to estimate the direction and the length of the sliding blocks. Third, local binary pattern histograms of the template and the sliding block are extracted, by which the self-shattered insulator can be recognized and located. Finally, a series of experiments is fulfilled to verify the effectiveness of the algorithm. For single insulator images, Ac, Pr, and Rc of the algorithm are 94.5%, 92.38%, and 96.78%, respectively. For double insulator images, Ac, Pr, and Rc are 90.00%, 86.36%, and 93.23%, respectively.

  11. A preliminary investigation of the growth of an aneurysm with a multiscale monolithic Fluid-Structure interaction solver

    NASA Astrophysics Data System (ADS)

    Cerroni, D.; Manservisi, S.; Pozzetti, G.

    2015-11-01

    In this work we investigate the potentialities of multi-scale engineering techniques to approach complex problems related to biomedical and biological fields. In particular we study the interaction between blood and blood vessel focusing on the presence of an aneurysm. The study of each component of the cardiovascular system is very difficult due to the fact that the movement of the fluid and solid is determined by the rest of system through dynamical boundary conditions. The use of multi-scale techniques allows us to investigate the effect of the whole loop on the aneurysm dynamic. A three-dimensional fluid-structure interaction model for the aneurysm is developed and coupled to a mono-dimensional one for the remaining part of the cardiovascular system, where a point zero-dimensional model for the heart is provided. In this manner it is possible to achieve rigorous and quantitative investigations of the cardiovascular disease without loosing the system dynamic. In order to study this biomedical problem we use a monolithic fluid-structure interaction (FSI) model where the fluid and solid equations are solved together. The use of a monolithic solver allows us to handle the convergence issues caused by large deformations. By using this monolithic approach different solid and fluid regions are treated as a single continuum and the interface conditions are automatically taken into account. In this way the iterative process characteristic of the commonly used segregated approach, it is not needed any more.

  12. Parallel Calculation of Sensitivity Derivatives for Aircraft Design using Automatic Differentiation

    NASA Technical Reports Server (NTRS)

    Bischof, c. H.; Green, L. L.; Haigler, K. J.; Knauff, T. L., Jr.

    1994-01-01

    Sensitivity derivative (SD) calculation via automatic differentiation (AD) typical of that required for the aerodynamic design of a transport-type aircraft is considered. Two ways of computing SD via code generated by the ADIFOR automatic differentiation tool are compared for efficiency and applicability to problems involving large numbers of design variables. A vector implementation on a Cray Y-MP computer is compared with a coarse-grained parallel implementation on an IBM SP1 computer, employing a Fortran M wrapper. The SD are computed for a swept transport wing in turbulent, transonic flow; the number of geometric design variables varies from 1 to 60 with coupling between a wing grid generation program and a state-of-the-art, 3-D computational fluid dynamics program, both augmented for derivative computation via AD. For a small number of design variables, the Cray Y-MP implementation is much faster. As the number of design variables grows, however, the IBM SP1 becomes an attractive alternative in terms of compute speed, job turnaround time, and total memory available for solutions with large numbers of design variables. The coarse-grained parallel implementation also can be moved easily to a network of workstations.

  13. Biothermal Model of Patient and Automatic Control System of Brain Temperature for Brain Hypothermia Treatment

    NASA Astrophysics Data System (ADS)

    Wakamatsu, Hidetoshi; Gaohua, Lu

    Various surface-cooling apparatus such as the cooling cap, muffler and blankets have been commonly used for the cooling of the brain to provide hypothermic neuro-protection for patients of hypoxic-ischemic encephalopathy. The present paper is aimed at the brain temperature regulation from the viewpoint of automatic system control, in order to help clinicians decide an optimal temperature of the cooling fluid provided for these three types of apparatus. At first, a biothermal model characterized by dynamic ambient temperatures is constructed for adult patient, especially on account of the clinical practice of hypothermia and anesthesia in the brain hypothermia treatment. Secondly, the model is represented by the state equation as a lumped parameter linear dynamic system. The biothermal model is justified from their various responses corresponding to clinical phenomena and treatment. Finally, the optimal regulator is tentatively designed to give clinicians some suggestions on the optimal temperature regulation of the patient’s brain. It suggests the patient’s brain temperature could be optimally controlled to follow-up the temperature process prescribed by the clinicians. This study benefits us a great clinical possibility for the automatic hypothermia treatment.

  14. Automatic segmentation of cerebral white matter hyperintensities using only 3D FLAIR images.

    PubMed

    Simões, Rita; Mönninghoff, Christoph; Dlugaj, Martha; Weimar, Christian; Wanke, Isabel; van Cappellen van Walsum, Anne-Marie; Slump, Cornelis

    2013-09-01

    Magnetic Resonance (MR) white matter hyperintensities have been shown to predict an increased risk of developing cognitive decline. However, their actual role in the conversion to dementia is still not fully understood. Automatic segmentation methods can help in the screening and monitoring of Mild Cognitive Impairment patients who take part in large population-based studies. Most existing segmentation approaches use multimodal MR images. However, multiple acquisitions represent a limitation in terms of both patient comfort and computational complexity of the algorithms. In this work, we propose an automatic lesion segmentation method that uses only three-dimensional fluid-attenuation inversion recovery (FLAIR) images. We use a modified context-sensitive Gaussian mixture model to determine voxel class probabilities, followed by correction of FLAIR artifacts. We evaluate the method against the manual segmentation performed by an experienced neuroradiologist and compare the results with other unimodal segmentation approaches. Finally, we apply our method to the segmentation of multiple sclerosis lesions by using a publicly available benchmark dataset. Results show a similar performance to other state-of-the-art multimodal methods, as well as to the human rater. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Automatic cortical segmentation in the developing brain.

    PubMed

    Xue, Hui; Srinivasan, Latha; Jiang, Shuzhou; Rutherford, Mary; Edwards, A David; Rueckert, Daniel; Hajnal, Jo V

    2007-01-01

    The segmentation of neonatal cortex from magnetic resonance (MR) images is much more challenging than the segmentation of cortex in adults. The main reason is the inverted contrast between grey matter (GM) and white matter (WM) that occurs when myelination is incomplete. This causes mislabeled partial volume voxels, especially at the interface between GM and cerebrospinal fluid (CSF). We propose a fully automatic cortical segmentation algorithm, detecting these mislabeled voxels using a knowledge-based approach and correcting errors by adjusting local priors to favor the correct classification. Our results show that the proposed algorithm corrects errors in the segmentation of both GM and WM compared to the classic EM scheme. The segmentation algorithm has been tested on 25 neonates with the gestational ages ranging from approximately 27 to 45 weeks. Quantitative comparison to the manual segmentation demonstrates good performance of the method (mean Dice similarity: 0.758 +/- 0.037 for GM and 0.794 +/- 0.078 for WM).

  16. Evaluation of an automatic brain segmentation method developed for neonates on adult MR brain images

    NASA Astrophysics Data System (ADS)

    Moeskops, Pim; Viergever, Max A.; Benders, Manon J. N. L.; Išgum, Ivana

    2015-03-01

    Automatic brain tissue segmentation is of clinical relevance in images acquired at all ages. The literature presents a clear distinction between methods developed for MR images of infants, and methods developed for images of adults. The aim of this work is to evaluate a method developed for neonatal images in the segmentation of adult images. The evaluated method employs supervised voxel classification in subsequent stages, exploiting spatial and intensity information. Evaluation was performed using images available within the MRBrainS13 challenge. The obtained average Dice coefficients were 85.77% for grey matter, 88.66% for white matter, 81.08% for cerebrospinal fluid, 95.65% for cerebrum, and 96.92% for intracranial cavity, currently resulting in the best overall ranking. The possibility of applying the same method to neonatal as well as adult images can be of great value in cross-sectional studies that include a wide age range.

  17. DTM-based automatic mapping and fractal clustering of putative mud volcanoes in Arabia Terra craters

    NASA Astrophysics Data System (ADS)

    Pozzobon, R. P.; Mazzarini, F. M.; Massironi, M. M.; Cremonese, G. C.; Rossi, A. P. R.; Pondrelli, M. P.; Marinangeli, L. M.

    2017-09-01

    Arabia Terra is a region of Mars where occurrence of past-water manifests at surface and subsurface. To date, several landforms associated with this activity were recognized and mapped, directly influencing the models of fluid circulation. In particular, within several craters such as Firsoff and an unnamed southern crater, putative mud volcanoes were described by several authors. In fact, numerous mounds (from 30 m of diameter in the case of monogenic cones, up to 3-400 m in the case of coalescing mounds) present an apical vent-like depression, resembling subaerial Azerbaijan mud volcanoes and gryphons. To this date, landform analysis through topographic position index and curvatures based on topography was never attempted. We hereby present a landform classification method suitable for mounds automatic mapping. Their resulting spatial distribution is then studied in terms of self-similar clustering.

  18. Research on Automatic Positioning System of Ultrasonic Testing of Wind Turbine Blade Flaws

    NASA Astrophysics Data System (ADS)

    Liu, Q. X.; Wang, Z. H.; Long, S. G.; Cai, M.; Cai, M.; Wang, X.; Chen, X. Y.; Bu, J. L.

    2017-11-01

    Ultrasonic testing technology has been used essentially in non-destructive testing of wind turbine blades. However, it is fact that the ultrasonic flaw detection method has inefficiently employed in recent years. This is because the testing result will illustrate a small deviation due to the artificial, environmental and technical factors. Therefore, it is an urgent technical demand for engineers to test the various flaws efficiently and quickly. An automatic positioning system has been designed in this paper to record the moving coordinates and the target distance in real time. Simultaneously, it could launch and acquire the sonic wave automatically. The ADNS-3080 optoelectronic chip is manufactured by Agilent Technologies Inc, which is also utilized in the system. With the combination of the chip, the power conversion module and the USB transmission module, the collected data can be transmitted from the upper monitor to the hardware that could process and control the data through software programming. An experiment has been designed to prove the reliability of automotive positioning system. The result has been validated by comparing the result collected form LABVIEW and actual plots on Perspex plane, it concludes that the system possesses high accuracy and magnificent meanings in practical engineering.

  19. Field Emission Gun Scanning Electron (FEGSEM) and Transmission Electron (TEM) Microscopy of Phyllosilicates in Martian Meteorites ALH84001, Nakhla, and Shergotty

    NASA Technical Reports Server (NTRS)

    Thomas-Keprta, Kathie L.; Wentworth, Susan J.; McKay, David S.; Gibson, Everett K.

    2000-01-01

    Here we document the occurrence of phyllosilicates and alteration phases in three martian meteorites, suggest formation conditions required for phyllosilicate formation and speculate on the extent of fluid:rock interactions during the past history of Mars.

  20. 77 FR 35683 - Agency Information Collection Activities; Proposed Collection; Comment Request; Public Health...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-14

    ... transmission among individuals through intimate contact with human body fluids. Human immunodeficiency virus... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0559... the public health and to help ensure the safety of using xenotransplantation products in humans by...

Top