Sample records for average absolute differences

  1. Wide-field absolute transverse blood flow velocity mapping in vessel centerline

    NASA Astrophysics Data System (ADS)

    Wu, Nanshou; Wang, Lei; Zhu, Bifeng; Guan, Caizhong; Wang, Mingyi; Han, Dingan; Tan, Haishu; Zeng, Yaguang

    2018-02-01

    We propose a wide-field absolute transverse blood flow velocity measurement method in vessel centerline based on absorption intensity fluctuation modulation effect. The difference between the light absorption capacities of red blood cells and background tissue under low-coherence illumination is utilized to realize the instantaneous and average wide-field optical angiography images. The absolute fuzzy connection algorithm is used for vessel centerline extraction from the average wide-field optical angiography. The absolute transverse velocity in the vessel centerline is then measured by a cross-correlation analysis according to instantaneous modulation depth signal. The proposed method promises to contribute to the treatment of diseases, such as those related to anemia or thrombosis.

  2. 9 CFR 439.10 - Criteria for obtaining accreditation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... absolute value of the average standardized difference must not exceed the following: (i) For food chemistry... samples must be less than 5.0. A result will have a large deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is less than 2.5 and otherwise a measure equal...

  3. 9 CFR 439.10 - Criteria for obtaining accreditation.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... absolute value of the average standardized difference must not exceed the following: (i) For food chemistry... samples must be less than 5.0. A result will have a large deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is less than 2.5 and otherwise a measure equal...

  4. 9 CFR 439.10 - Criteria for obtaining accreditation.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... absolute value of the average standardized difference must not exceed the following: (i) For food chemistry... samples must be less than 5.0. A result will have a large deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is less than 2.5 and otherwise a measure equal...

  5. 9 CFR 439.10 - Criteria for obtaining accreditation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... absolute value of the average standardized difference must not exceed the following: (i) For food chemistry... samples must be less than 5.0. A result will have a large deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is less than 2.5 and otherwise a measure equal...

  6. 9 CFR 439.10 - Criteria for obtaining accreditation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... absolute value of the average standardized difference must not exceed the following: (i) For food chemistry... samples must be less than 5.0. A result will have a large deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is less than 2.5 and otherwise a measure equal...

  7. Intra- and Interobserver Variability of Cochlear Length Measurements in Clinical CT.

    PubMed

    Iyaniwura, John E; Elfarnawany, Mai; Riyahi-Alam, Sadegh; Sharma, Manas; Kassam, Zahra; Bureau, Yves; Parnes, Lorne S; Ladak, Hanif M; Agrawal, Sumit K

    2017-07-01

    The cochlear A-value measurement exhibits significant inter- and intraobserver variability, and its accuracy is dependent on the visualization method in clinical computed tomography (CT) images of the cochlea. An accurate estimate of the cochlear duct length (CDL) can be used to determine electrode choice, and frequency map the cochlea based on the Greenwood equation. Studies have described estimating the CDL using a single A-value measurement, however the observer variability has not been assessed. Clinical and micro-CT images of 20 cadaveric cochleae were acquired. Four specialists measured A-values on clinical CT images using both standard views and multiplanar reconstructed (MPR) views. Measurements were repeated to assess for intraobserver variability. Observer variabilities were evaluated using intra-class correlation and absolute differences. Accuracy was evaluated by comparison to the gold standard micro-CT images of the same specimens. Interobserver variability was good (average absolute difference: 0.77 ± 0.42 mm) using standard views and fair (average absolute difference: 0.90 ± 0.31 mm) using MPR views. Intraobserver variability had an average absolute difference of 0.31 ± 0.09 mm for the standard views and 0.38 ± 0.17 mm for the MPR views. MPR view measurements were more accurate than standard views, with average relative errors of 9.5 and 14.5%, respectively. There was significant observer variability in A-value measurements using both the standard and MPR views. Creating the MPR views increased variability between experts, however MPR views yielded more accurate results. Automated A-value measurement algorithms may help to reduce variability and increase accuracy in the future.

  8. Intelligence May Moderate the Cognitive Profile of Patients with ASD.

    PubMed

    Rommelse, Nanda; Langerak, Ilse; van der Meer, Jolanda; de Bruijn, Yvette; Staal, Wouter; Oerlemans, Anoek; Buitelaar, Jan

    2015-01-01

    The intelligence of individuals with Autism Spectrum Disorder (ASD) varies considerably. The pattern of cognitive deficits associated with ASD may differ depending on intelligence. We aimed to study the absolute and relative severity of cognitive deficits in participants with ASD in relation to IQ. A total of 274 children (M age = 12.1, 68.6% boys) participated: 30 ASD and 22 controls in the below average Intelligence Quotient (IQ) group (IQ<85), 57 ASD and 54 controls in the average IQ group (85115). Matching for age, sex, Full Scale IQ (FSIQ), Verbal IQ (VIQ), Performance IQ (PIQ) and VIQ-PIQ difference was performed. Speed and accuracy of social cognition, executive functioning, visual pattern recognition and basic processing speed were examined per domain and as a composite score. The composite score revealed a trend significant IQ by ASD interaction (significant when excluding the average IQ group). In absolute terms, participants with below average IQs performed poorest (regardless of diagnosis). However, in relative terms, above average intelligent participants with ASD showed the most substantial cognitive problems (particularly for social cognition, visual pattern recognition and verbal working memory) since this group differed significantly from the IQ-matched control group (p < .001), whereas this was not the case for below-average intelligence participants with ASD (p = .57). In relative terms, cognitive deficits appear somewhat more severe in individuals with ASD and above average IQs compared to the below average IQ patients with ASD. Even though high IQ ASD individuals enjoy a certain protection from their higher IQ, they clearly demonstrate cognitive impairments that may be targeted in clinical assessment and treatment. Conversely, even though in absolute terms ASD patients with below average IQs were clearly more impaired than ASD patients with average to above average IQs, the differences in cognitive functioning between participants with and without ASD on the lower end of the IQ spectrum were less pronounced. Clinically this may imply that cognitive assessment and training of cognitive skills in below average intelligent children with ASD may be a less fruitful endeavour. These findings tentatively suggest that intelligence may act as a moderator in the cognitive presentation of ASD, with qualitatively different cognitive processes affected in patients at the high and low end of the IQ spectrum.

  9. Intelligence May Moderate the Cognitive Profile of Patients with ASD

    PubMed Central

    Rommelse, Nanda; Langerak, Ilse; van der Meer, Jolanda; de Bruijn, Yvette; Staal, Wouter; Oerlemans, Anoek; Buitelaar, Jan

    2015-01-01

    Background The intelligence of individuals with Autism Spectrum Disorder (ASD) varies considerably. The pattern of cognitive deficits associated with ASD may differ depending on intelligence. We aimed to study the absolute and relative severity of cognitive deficits in participants with ASD in relation to IQ. Methods A total of 274 children (M age = 12.1, 68.6% boys) participated: 30 ASD and 22 controls in the below average Intelligence Quotient (IQ) group (IQ<85), 57 ASD and 54 controls in the average IQ group (85115). Matching for age, sex, Full Scale IQ (FSIQ), Verbal IQ (VIQ), Performance IQ (PIQ) and VIQ-PIQ difference was performed. Speed and accuracy of social cognition, executive functioning, visual pattern recognition and basic processing speed were examined per domain and as a composite score. Results The composite score revealed a trend significant IQ by ASD interaction (significant when excluding the average IQ group). In absolute terms, participants with below average IQs performed poorest (regardless of diagnosis). However, in relative terms, above average intelligent participants with ASD showed the most substantial cognitive problems (particularly for social cognition, visual pattern recognition and verbal working memory) since this group differed significantly from the IQ-matched control group (p < .001), whereas this was not the case for below-average intelligence participants with ASD (p = .57). Conclusions In relative terms, cognitive deficits appear somewhat more severe in individuals with ASD and above average IQs compared to the below average IQ patients with ASD. Even though high IQ ASD individuals enjoy a certain protection from their higher IQ, they clearly demonstrate cognitive impairments that may be targeted in clinical assessment and treatment. Conversely, even though in absolute terms ASD patients with below average IQs were clearly more impaired than ASD patients with average to above average IQs, the differences in cognitive functioning between participants with and without ASD on the lower end of the IQ spectrum were less pronounced. Clinically this may imply that cognitive assessment and training of cognitive skills in below average intelligent children with ASD may be a less fruitful endeavour. These findings tentatively suggest that intelligence may act as a moderator in the cognitive presentation of ASD, with qualitatively different cognitive processes affected in patients at the high and low end of the IQ spectrum. PMID:26444877

  10. SU-E-T-379: Evaluation of An EPID-Based System for Daily Dosimetry Check by Comparison with a Widely-Used Ionization Chamber-Based Device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDonald, D; Koch, N; Peng, J

    2015-06-15

    Purpose: To examine the feasibility of using Varian’s EPID-based Machine Performance Check (MPC) system to track daily machine output through comparison with Sun Nuclear’s DailyQA3 (DQA) device. Methods: Daily machine outputs for two photon energies (6 and 16MV) and five electron energies (6, 9, 12, 16, 20MeV) were measured for one month using both MPC and DQA. Baselines measurements for MPC were taken at the start of the measurement series, while DQA baselines were set at an earlier date. In order to make absolute comparisons with MPC, all DQA readings were referenced to the average of the first three DQAmore » readings in that series, minimizing systematic differences between the measurement techniques due to baseline differences. In addition to daily output measurements, weekly averages were also calculated and compared. Finally, the electron energy dependence of each measurement technique was examined by comparing energy-specific measurements to the average electron output of all energies each day. Results: For 6 and 16MV photons, the largest absolute percent differences between MPC and DQA were 0.60% and 0.73%, respectively. Weekly averages were within 0.17% and 0.23%, respectively. For all five electron energies, the greatest absolute percent differences between MPC and DQA for each energy ranged from 0.49%–0.83%. Weekly averages ranged from 0.07%–0.28%. DQA energy-specific electron readings matched the average electron output within 0.29% for all days and all energies. MPC energy-specific readings matched the average within 0.21% for 9–20MeV. However, 6MeV showed a larger distribution about the average with four days showing a difference greater than 0.30% and a maximum difference of 0.51%. Conclusion: MPC output measurements correlated well with the widely-used DQA3 for most beam energies, making it a reliable back up technique for daily output monitoring. However, MPC may display an energy dependence for lower electrons energies, requiring additional investigation.« less

  11. A system for automatic aorta sections measurements on chest CT

    NASA Astrophysics Data System (ADS)

    Pfeffer, Yitzchak; Mayer, Arnaldo; Zholkover, Adi; Konen, Eli

    2016-03-01

    A new method is proposed for caliber measurement of the ascending aorta (AA) and descending aorta (DA). A key component of the method is the automatic detection of the carina, as an anatomical landmark around which an axial volume of interest (VOI) can be defined to observe the aortic caliber. For each slice in the VOI, a linear profile line connecting the AA with the DA is found by pattern matching on the underlying intensity profile. Next, the aortic center position is found using Hough transform on the best linear segment candidate. Finally, region growing around the center provides an accurate segmentation and caliber measurement. We evaluated the algorithm on 113 sequential chest CT scans, slice thickness of 0.75 - 3.75mm, 90 with contrast agent injected. The algorithm success rates were computed as the percentage of scans in which the center of the AA was found. Automated measurements of AA caliber were compared with independent measurements of two experienced chest radiologists, comparing the absolute difference between the two radiologists with the absolute difference between the algorithm and each of the radiologists. The measurement stability was demonstrated by computing the STD of the absolute difference between the radiologists, and between the algorithm and the radiologists. Results: Success rates of 93% and 74% were achieved, for contrast injected cases and non-contrast cases, respectively. These results indicate that the algorithm can be robust in large variability of image quality, such as the cases in a realworld clinical setting. The average absolute difference between the algorithm and the radiologists was 1.85mm, lower than the average absolute difference between the radiologists, which was 2.1mm. The STD of the absolute difference between the algorithm and the radiologists was 1.5mm vs 1.6mm between the two radiologists. These results demonstrate the clinical relevance of the algorithm measurements.

  12. Mental health care and average happiness: strong effect in developed nations.

    PubMed

    Touburg, Giorgio; Veenhoven, Ruut

    2015-07-01

    Mental disorder is a main cause of unhappiness in modern society and investment in mental health care is therefore likely to add to average happiness. This prediction was checked in a comparison of 143 nations around 2005. Absolute investment in mental health care was measured using the per capita number of psychiatrists and psychologists working in mental health care. Relative investment was measured using the share of mental health care in the total health budget. Average happiness in nations was measured with responses to survey questions about life-satisfaction. Average happiness appeared to be higher in countries that invest more in mental health care, both absolutely and relative to investment in somatic medicine. A data split by level of development shows that this difference exists only among developed nations. Among these nations the link between mental health care and happiness is quite strong, both in an absolute sense and compared to other known societal determinants of happiness. The correlation between happiness and share of mental health care in the total health budget is twice as strong as the correlation between happiness and size of the health budget. A causal effect is likely, but cannot be proved in this cross-sectional analysis.

  13. Nonprobability Web Surveys to Measure Sexual Behaviors and Attitudes in the General Population: A Comparison With a Probability Sample Interview Survey

    PubMed Central

    Burkill, Sarah; Couper, Mick P; Conrad, Frederick; Clifton, Soazig; Tanton, Clare; Phelps, Andrew; Datta, Jessica; Mercer, Catherine H; Sonnenberg, Pam; Prah, Philip; Mitchell, Kirstin R; Wellings, Kaye; Johnson, Anne M; Copas, Andrew J

    2014-01-01

    Background Nonprobability Web surveys using volunteer panels can provide a relatively cheap and quick alternative to traditional health and epidemiological surveys. However, concerns have been raised about their representativeness. Objective The aim was to compare results from different Web panels with a population-based probability sample survey (n=8969 aged 18-44 years) that used computer-assisted self-interview (CASI) for sensitive behaviors, the third British National Survey of Sexual Attitudes and Lifestyles (Natsal-3). Methods Natsal-3 questions were included on 4 nonprobability Web panel surveys (n=2000 to 2099), 2 using basic quotas based on age and sex, and 2 using modified quotas based on additional variables related to key estimates. Results for sociodemographic characteristics were compared with external benchmarks and for sexual behaviors and opinions with Natsal-3. Odds ratios (ORs) were used to express differences between the benchmark data and each survey for each variable of interest. A summary measure of survey performance was the average absolute OR across variables. Another summary measure was the number of key estimates for which the survey differed significantly (at the 5% level) from the benchmarks. Results For sociodemographic variables, the Web surveys were less representative of the general population than Natsal-3. For example, for men, the average absolute OR for Natsal-3 was 1.14, whereas for the Web surveys the average absolute ORs ranged from 1.86 to 2.30. For all Web surveys, approximately two-thirds of the key estimates of sexual behaviors were different from Natsal-3 and the average absolute ORs ranged from 1.32 to 1.98. Differences were appreciable even for questions asked by CASI in Natsal-3. No single Web survey performed consistently better than any other did. Modified quotas slightly improved results for men, but not for women. Conclusions Consistent with studies from other countries on less sensitive topics, volunteer Web panels provided appreciably biased estimates. The differences seen with Natsal-3 CASI questions, where mode effects may be similar, suggest a selection bias in the Web surveys. The use of more complex quotas may lead to some improvement, but many estimates are still likely to differ. Volunteer Web panels are not recommended if accurate prevalence estimates for the general population are a key objective. PMID:25488851

  14. Use of modern contraception by the poor is falling behind.

    PubMed

    Gakidou, Emmanuela; Vayena, Effy

    2007-02-01

    The widespread increase in the use of contraception, due to multiple factors including improved access to modern contraception, is one of the most dramatic social transformations of the past fifty years. This study explores whether the global progress in the use of modern contraceptives has also benefited the poorest. Demographic and Health Surveys from 55 developing countries were analyzed using wealth indices that allow the identification of the absolute poor within each country. This article explores the macro level determinants of the differences in the use of modern contraceptives between the poor and the national averages of several countries. Despite increases in national averages, use of modern contraception by the absolute poor remains low. South and Southeast Asia have relatively high rates of modern contraception in the absolute poor, on average 17% higher than in Latin America. Over time the gaps in use persist and are increasing. Latin America exhibits significantly larger gaps in use between the poor and the averages, while gaps in sub-Saharan Africa are on average smaller by 15.8% and in Southeast Asia by 11.6%. The secular trend of increasing rates of modern contraceptive use has not resulted in a decrease of the gap in use for those living in absolute poverty. Countries with large economic inequalities also exhibit large inequalities in modern contraceptive use. In addition to macro level factors that influence contraceptive use, such as economic development and provision of reproductive health services, there are strong regional variations, with sub-Saharan Africa exhibiting the lowest national rates of use, South and Southeast Asia the highest use among the poor, and Latin America the largest inequalities in use.

  15. Esophageal motion during radiotherapy: quantification and margin implications.

    PubMed

    Cohen, R J; Paskalev, K; Litwin, S; Price, R A; Feigenberg, S J; Konski, A A

    2010-08-01

    The purpose was to evaluate interfraction and intrafraction esophageal motion in the right-left (RL) and anterior-posterior (AP) directions using computed tomography (CT) in esophageal cancer patients. Eight patients underwent CT simulation and CT-on-rails imaging before and after radiotherapy. Interfraction displacement was defined as differences between pretreatment and simulation images. Intrafraction displacement was defined as differences between pretreatment and posttreatment images. Images were fused using bone registries, adjusted to the carina. The mean, average of the absolute, and range of esophageal motion were calculated in the RL and AP directions, above and below the carina. Thirty-one CT image sets were obtained. The incidence of esophageal interfraction motion > or =5 mm was 24% and > or =10 mm was 3%; intrafraction motion > or =5 mm was 13% and > or =10 mm was 4%. The average RL motion was 1.8 +/- 5.1 mm, favoring leftward movement, and the average AP motion was 0.6 +/- 4.8 mm, favoring posterior movement. Average absolute motion was 4.2 mm or less in the RL and AP directions. Motion was greatest in the RL direction above the carina. Coverage of 95% of esophageal mobility requires 12 mm left, 8 mm right, 10 mm posterior, and 9 mm anterior margins. In all directions, the average of the absolute interfraction and intrafraction displacement was 4.2 mm or less. These results support a 12 mm left, 8 mm right, 10 mm posterior, and 9 mm anterior margin for internal target volume (ITV) and can guide margins for future intensity modulated radiation therapy (IMRT) trials to account for organ motion and set up error in three-dimensional planning.

  16. Simultaneous blood pressure measurement in both arms in hypertensive and nonhypertensive adult patients.

    PubMed

    Fonseca-Reyes, Salvador; Forsyth-MacQuarrie, Avril M; García de Alba-García, Javier Eduardo

    2012-08-01

    When blood pressure (BP) is taken for the first time, it should be measured in both arms; follow-up measurements should be taken in the arm with the highest BP. However, in clinical practice, this recommendation is rarely followed. Identify the degree of differences in BP between the right and the left arm in individuals with normal and high BP. We measured BP in 111 hypertensive and 80 normotensive patients in both arms at the same time using identical Omron HEM 725 CIC automatic sphygmomanometers. The devices were then switched to the other arm and another set of readings was taken. The absolute and relative difference in BP between arms was calculated from the average of these two readings. We categorized differences as at least 5, at least 10, and at least 20 mmHg for systolic blood pressure/diastolic blood pressure (SBP/DBP). The BP was higher in the right arm, with no statistical significance. The relative differences were also not significant: SBP 1.1±7.1 and DBP 0.21±5.0. However, the absolute differences were significant at an individual level, with a systolic difference of 5.4±4.8 mmHg and a diastolic difference of 3.9 ±3.2 mmHg. The percentages of absolute SBP/DBP differences more than 5 mmHg (21.4%/20.4%) and more than 10 mmHg (15.7%/4.7%) were considerable. The range of arm differences was clinically significant; in hypertensives, the SBP/DBP was -13.2 to +15/-9.2 to +9.6 mmHg and in nonhypertensives it was -12.9 to +15.6/-9.7 to +10.1 mmHg. Although on average there was no clinically significant relative difference between arms, absolute differences at an individual level were often clinically significant. Failure to determine interarm BP differences will lead to erroneous clinical decisions.

  17. Design with limited anthropometric data: A method of interpreting sums of percentiles in anthropometric design.

    PubMed

    Albin, Thomas J

    2017-07-01

    Occasionally practitioners must work with single dimensions defined as combinations (sums or differences) of percentile values, but lack information (e.g. variances) to estimate the accommodation achieved. This paper describes methods to predict accommodation proportions for such combinations of percentile values, e.g. two 90th percentile values. Kreifeldt and Nah z-score multipliers were used to estimate the proportions accommodated by combinations of percentile values of 2-15 variables; two simplified versions required less information about variance and/or correlation. The estimates were compared to actual observed proportions; for combinations of 2-15 percentile values the average absolute differences ranged between 0.5 and 1.5 percentage points. The multipliers were also used to estimate adjusted percentile values, that, when combined, estimate a desired proportion of the combined measurements. For combinations of two and three adjusted variables, the average absolute difference between predicted and observed proportions ranged between 0.5 and 3.0 percentage points. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Estimation of lower flammability limits of C-H compounds in air at atmospheric pressure, evaluation of temperature dependence and diluent effect.

    PubMed

    Mendiburu, Andrés Z; de Carvalho, João A; Coronado, Christian R

    2015-03-21

    Estimation of the lower flammability limits of C-H compounds at 25 °C and 1 atm; at moderate temperatures and in presence of diluent was the objective of this study. A set of 120 C-H compounds was divided into a correlation set and a prediction set of 60 compounds each. The absolute average relative error for the total set was 7.89%; for the correlation set, it was 6.09%; and for the prediction set it was 9.68%. However, it was shown that by considering different sources of experimental data the values were reduced to 6.5% for the prediction set and to 6.29% for the total set. The method showed consistency with Le Chatelier's law for binary mixtures of C-H compounds. When tested for a temperature range from 5 °C to 100 °C, the absolute average relative errors were 2.41% for methane; 4.78% for propane; 0.29% for iso-butane and 3.86% for propylene. When nitrogen was added, the absolute average relative errors were 2.48% for methane; 5.13% for propane; 0.11% for iso-butane and 0.15% for propylene. When carbon dioxide was added, the absolute relative errors were 1.80% for methane; 5.38% for propane; 0.86% for iso-butane and 1.06% for propylene. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Formulas of Site Index Prediction Tables for Oak in Missouri

    Treesearch

    Harry V. Jr. Wiant; Robert A. McQuilkin

    1976-01-01

    Recently published site index prediction tables for oak in Missouri were fomulized using the "matchacurve" system. The average absolute differences between formula and table values were .8 feet for white oak and 1.4 feet for black and scarlet oaks; maximum differences were 3.0 and 4.2 feet, respectively.

  20. [Reproductive biology and artificial propagation of Acipenser sinensis below Gezhouba Dam].

    PubMed

    Liu, Jian-yi; Wei, Qi-wei; Chen, Xi-hua; Yang, De-guo; Du, Hao; Zhu, Yong-jiu

    2007-06-01

    A total of 36 females and 21 males of Chinese sturgeon Acipenser sinensis were caught in 1998-2004 excluding 2002 to study the characteristics of their reproductive biology and the effect of their artificial propagation. The results showed that the body length (BL), body mass (BM) and age of the females were 240-320 cm, 140-432 kg, and 15-30 years, and those of the males were 153-284 cm, 70-244 kg and 12-26 years, respectively. The inducing rate was 93.1% for females and 100% for males, and the ova had 7 different colors. The absolute fecundity was 200,000-590,000 eggs, with an average of 358,000 eggs, and the relative fecundity to BM was 820-3,020 eggs per kg, with an average of 1,590 eggs per kg. The sperm had 4 different colors. The absolute sperm quantity obtained from one male was 1,000-5,952 ml, with an average of 2,597.8 ml, and the relative sperm quantity to BM was 1.25-31.24 ml . kg(-1), with an average of 13.3 ml . kg(-1). During the study period, the average fertilization rate in artificial propagation was 63.7%, and the hatching rate was 48.1%, with 4,762,000 fry obtained. Compared with the data in 1976, the natural reproductive capacity of the Chinese sturgeon broodstocks declined greatly.

  1. Modelling second malignancy risks from low dose rate and high dose rate brachytherapy as monotherapy for localised prostate cancer.

    PubMed

    Murray, Louise; Mason, Joshua; Henry, Ann M; Hoskin, Peter; Siebert, Frank-Andre; Venselaar, Jack; Bownes, Peter

    2016-08-01

    To estimate the risks of radiation-induced rectal and bladder cancers following low dose rate (LDR) and high dose rate (HDR) brachytherapy as monotherapy for localised prostate cancer and compare to external beam radiotherapy techniques. LDR and HDR brachytherapy monotherapy plans were generated for three prostate CT datasets. Second cancer risks were assessed using Schneider's concept of organ equivalent dose. LDR risks were assessed according to a mechanistic model and a bell-shaped model. HDR risks were assessed according to a bell-shaped model. Relative risks and excess absolute risks were estimated and compared to external beam techniques. Excess absolute risks of second rectal or bladder cancer were low for both LDR (irrespective of the model used for calculation) and HDR techniques. Average excess absolute risks of rectal cancer for LDR brachytherapy according to the mechanistic model were 0.71 per 10,000 person-years (PY) and 0.84 per 10,000 PY respectively, and according to the bell-shaped model, were 0.47 and 0.78 per 10,000 PY respectively. For HDR, the average excess absolute risks for second rectal and bladder cancers were 0.74 and 1.62 per 10,000 PY respectively. The absolute differences between techniques were very low and clinically irrelevant. Compared to external beam prostate radiotherapy techniques, LDR and HDR brachytherapy resulted in the lowest risks of second rectal and bladder cancer. This study shows both LDR and HDR brachytherapy monotherapy result in low estimated risks of radiation-induced rectal and bladder cancer. LDR resulted in lower bladder cancer risks than HDR, and lower or similar risks of rectal cancer. In absolute terms these differences between techniques were very small. Compared to external beam techniques, second rectal and bladder cancer risks were lowest for brachytherapy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. 75 FR 20813 - Certain Magnesia Carbon Bricks from the People's Republic of China: Amended Preliminary...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-21

    ... other errors, would result in (1) a change of at least five absolute percentage points in, but not less...) preliminary determination, or (2) a difference between a weighted-average dumping margin of zero or de minimis...

  3. Fine-scale structure of the San Andreas fault zone and location of the SAFOD target earthquakes

    USGS Publications Warehouse

    Thurber, C.; Roecker, S.; Zhang, H.; Baher, S.; Ellsworth, W.

    2004-01-01

    We present results from the tomographic analysis of seismic data from the Parkfield area using three different inversion codes. The models provide a consistent view of the complex velocity structure in the vicinity of the San Andreas, including a sharp velocity contrast across the fault. We use the inversion results to assess our confidence in the absolute location accuracy of a potential target earthquake. We derive two types of accuracy estimates, one based on a consideration of the location differences from the three inversion methods, and the other based on the absolute location accuracy of "virtual earthquakes." Location differences are on the order of 100-200 m horizontally and up to 500 m vertically. Bounds on the absolute location errors based on the "virtual earthquake" relocations are ??? 50 m horizontally and vertically. The average of our locations places the target event epicenter within about 100 m of the SAF surface trace. Copyright 2004 by the American Geophysical Union.

  4. Robust Alternatives to the Standard Deviation in Processing of Physics Experimental Data

    NASA Astrophysics Data System (ADS)

    Shulenin, V. P.

    2016-10-01

    Properties of robust estimations of the scale parameter are studied. It is noted that the median of absolute deviations and the modified estimation of the average Gini differences have asymptotically normal distributions and bounded influence functions, are B-robust estimations, and hence, unlike the estimation of the standard deviation, are protected from the presence of outliers in the sample. Results of comparison of estimations of the scale parameter are given for a Gaussian model with contamination. An adaptive variant of the modified estimation of the average Gini differences is considered.

  5. An Evaluation of Functional Sit-to-Stand Power in Cohorts of Healthy Adults Aged 18-97 Years.

    PubMed

    Glenn, Jordan M; Gray, Michelle; Vincenzo, Jennifer; Paulson, Sally; Powers, Melissa

    2017-04-01

    This investigation examined differences in functional sit-to-stand power/velocity between cohorts of adults aged 18-97 years. This study included 264 healthy adults classified into four cohorts (18-40, C1; 60-69, C2; 70-79, C2; ≥ 80, C4). Participants completed the sit-to-stand task five times. Power and velocity were measured via the TENDO power analyzer. Absolute average power was maintained from C1-C3, but decreased (p < .01) in C4. Absolute peak power decreased between C1-C2 (p < .01), was similar between C2-C3, and decreased in C4 (p < .01). Relative (to body weight) average and peak power decreased between C1-C2 (p < .01), was similar between C2-C3, and decreased in C4 (p < .01). Average velocity was similar between C1 and C2, but decreased in C3 (p < .01) and C4 (p < .01), respectively. Peak velocity was significantly different between all cohorts (p < .01). Declines in functional power may plateau during the seventh and eighth decades, accelerating after 80 years.

  6. High frequency source localization in a shallow ocean sound channel using frequency difference matched field processing.

    PubMed

    Worthmann, Brian M; Song, H C; Dowling, David R

    2015-12-01

    Matched field processing (MFP) is an established technique for source localization in known multipath acoustic environments. Unfortunately, in many situations, particularly those involving high frequency signals, imperfect knowledge of the actual propagation environment prevents accurate propagation modeling and source localization via MFP fails. For beamforming applications, this actual-to-model mismatch problem was mitigated through a frequency downshift, made possible by a nonlinear array-signal-processing technique called frequency difference beamforming [Abadi, Song, and Dowling (2012). J. Acoust. Soc. Am. 132, 3018-3029]. Here, this technique is extended to conventional (Bartlett) MFP using simulations and measurements from the 2011 Kauai Acoustic Communications MURI experiment (KAM11) to produce ambiguity surfaces at frequencies well below the signal bandwidth where the detrimental effects of mismatch are reduced. Both the simulation and experimental results suggest that frequency difference MFP can be more robust against environmental mismatch than conventional MFP. In particular, signals of frequency 11.2 kHz-32.8 kHz were broadcast 3 km through a 106-m-deep shallow ocean sound channel to a sparse 16-element vertical receiving array. Frequency difference MFP unambiguously localized the source in several experimental data sets with average peak-to-side-lobe ratio of 0.9 dB, average absolute-value range error of 170 m, and average absolute-value depth error of 10 m.

  7. APOLLO: a quality assessment service for single and multiple protein models.

    PubMed

    Wang, Zheng; Eickholt, Jesse; Cheng, Jianlin

    2011-06-15

    We built a web server named APOLLO, which can evaluate the absolute global and local qualities of a single protein model using machine learning methods or the global and local qualities of a pool of models using a pair-wise comparison approach. Based on our evaluations on 107 CASP9 (Critical Assessment of Techniques for Protein Structure Prediction) targets, the predicted quality scores generated from our machine learning and pair-wise methods have an average per-target correlation of 0.671 and 0.917, respectively, with the true model quality scores. Based on our test on 92 CASP9 targets, our predicted absolute local qualities have an average difference of 2.60 Å with the actual distances to native structure. http://sysbio.rnet.missouri.edu/apollo/. Single and pair-wise global quality assessment software is also available at the site.

  8. 75 FR 29972 - Certain Seamless Carbon and Alloy Steel Standard, Line, and Pressure Pipe from the People's...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-28

    ... errors, (1) would result in a change of at least five absolute percentage points in, but not less than 25... determination; or (2) would result in a difference between a weighted-average dumping margin of zero or de...

  9. Results from laboratory and field testing of nitrate measuring spectrophotometers

    USGS Publications Warehouse

    Snazelle, Teri T.

    2015-01-01

    In Phase II, the analyzers were deployed in field conditions at three diferent USGS sites. The measured nitrate concentrations were compared to discrete (reference) samples analyzed by the Direct UV method on a Shimadzu UV1800 bench top spectrophotometer, and by the National Environmental Methods Index (NEMI) method I-2548-11 at the USGS National Water Quality Laboratory. The first deployment at USGS site 0249620 on the East Pearl River in Hancock County, Mississippi, tested the ability of the TriOs ProPs (10-mm path length), Hach NITRATAX (5 mm), Satlantic SUNA (10 mm), and the S::CAN Spectro::lyser (5 mm) to accurately measure low-level (less than 2 mg-N/L) nitrate concentrations while observing the effect turbidity and colored dissolved organic matter (CDOM) would have on the analyzers' measurements. The second deployment at USGS site 01389005 Passaic River below Pompton River at Two Bridges, New Jersey, tested the analyzer's accuracy in mid-level (2-8 mg-N/L) nitrate concentrations. This site provided the means to test the analyzers' performance in two distinct matrices—the Passaic and the Pompton Rivers. In this deployment, three instruments tested in Phase I (TriOS, Hach, and SUNA) were deployed with the S::CAN Spectro::lyser (35 mm) already placed by the New Jersey Water Science Center (WSC). The third deployment at USGS site 05579610 Kickapoo Creek at 2100E Road near Bloomington, Illinois, tested the ability of the analyzers to measure high nitrate concentrations (greater than 8 mg-N/L) in turbid waters. For Kickapoo Creek, the HIF provided the TriOS (10 mm) and S::CAN (5 mm) from Phase I, and a SUNA V2 (5 mm) to be deployed adjacent to the Illinois WSC-owned Hach (2 mm). A total of 40 discrete samples were collected from the three deployment sites and analyzed. The nitrate concentration of the samples ranged from 0.3–22.2 mg-N/L. The average absolute difference between the TriOS measurements and discrete samples was 0.46 mg-N/L. For the combined data from the Hach 5-mm and 2-mm analyzers, the average absolute difference between the Hach samples and the discrete samples was 0.13 mg-N/L. For the SUNA and SUNA V2 combined data, the average absolute difference between the SUNA samples and the discrete samples was 0.66 mg-N/L. The average absolute difference between the S::CAN samples and the discrete samples was 0.63 mg-N/L.

  10. Physical fitness and performance. Cardiorespiratory fitness in girls-change from middle to high school.

    PubMed

    Pfeiffer, Karin A; Dowda, Marsha; Dishman, Rod K; Sirard, John R; Pate, Russell R

    2007-12-01

    To determine how factors are related to change in cardiorespiratory fitness (CRF) across time in middle school girls followed through high school. Adolescent girls (N = 274, 59% African American, baseline age = 13.6 +/- 0.6 yr) performed a submaximal fitness test (PWC170) in 8th, 9th, and 12th grades. Height, weight, sports participation, and physical activity were also measured. Moderate-to-vigorous physical activity (MVPA) and vigorous physical activity (VPA) were determined by the number of blocks reported on the 3-Day Physical Activity Recall (3DPAR). Individual differences and developmental change in CRF were assessed simultaneously by calculating individual growth curves for each participant, using growth curve modeling. Both weight-relative and absolute CRF increased from 8th to 9th grade and decreased from 9th to 12th grade. On average, girls lost 0.16 kg.m.min.kg.yr in weight-relative PWC170 scores (P < 0.01) and gained 10.3 kg.m.min.yr in absolute PWC170 scores. Girls reporting two or more blocks of MVPA or one or more blocks of VPA at baseline showed an average increase in PWC170 scores of 0.40-0.52 kg.m.min.kg.yr (weight relative) and 22-28 kg.m.min.yr (absolute) in CRF. In weight-relative models, girls with higher BMI showed lower CRF (approximately 0.37 g.m.min.kg.yr), but this was not shown in absolute models. In absolute models, white girls (approximately 40 kg.m.min.yr) and sport participants (approximately 28 kg.m.min.yr) showed an increase in CRF over time. Although there were fluctuations in PWC170 scores across time, average scores decreased during 4 yr. Physical activity was related to change in CRF over time; BMI, race, and sport participation were also important factors related to change over time in CRF (depending on expression of CRF-weight-relative vs absolute). Subsequent research should focus on explaining the complex longitudinal interactions between CRF, physical activity, race, BMI, and sports participation.

  11. A Typology for Charting Socioeconomic Mortality Gradients: "Go Southwest".

    PubMed

    Blakely, Tony; Disney, George; Atkinson, June; Teng, Andrea; Mackenbach, Johan P

    2017-07-01

    Holistic depiction of time-trends in average mortality rates, and absolute and relative inequalities, is challenging. We outline a typology for situations with falling average mortality rates (m↓; e.g., cardiovascular disease), rates stable over time (m-; e.g., some cancers), and increasing average mortality rates (m↑; e.g., suicide in some contexts). If we consider inequality trends on both the absolute (a) and relative (r) scales, there are 13 possible combination of m, a, and r trends over time. They can be mapped to graphs with relative inequality (log relative index of inequality [RII]; r) on the y axis, log average mortality rate on the x axis (m), and absolute inequality (slope index of inequality; SII; a) as contour lines. We illustrate this by plotting adult mortality trends: (1) by household income from 1981 to 2011 for New Zealand, and (2) by education for European countries. Types range from the "best" m↓a↓r↓ (average, absolute, and relative inequalities all decreasing; southwest movement in graphs) to the "worst" m↑a↑r↑ (northeast). Mortality typologies in New Zealand (all-cause, cardiovascular disease, nonlung cancer, and unintentional injury) were all m↓r↑ (northwest), but variable with respect to absolute inequality. Most European typologies were m↓r↑ types (northwest; e.g., Finland), but with notable exceptions of m-a↑r↑ (north; e.g., Hungary) and "best" or southwest m↓a↓r↓ for Spain (Barcelona) females. Our typology and corresponding graphs provide a convenient way to summarize and understand past trends in inequalities in mortality, and hold potential for projecting future trends and target setting.

  12. Statistical properties of edge plasma turbulence in the Large Helical Device

    NASA Astrophysics Data System (ADS)

    Dewhurst, J. M.; Hnat, B.; Ohno, N.; Dendy, R. O.; Masuzaki, S.; Morisaki, T.; Komori, A.

    2008-09-01

    Ion saturation current (Isat) measurements made by three tips of a Langmuir probe array in the Large Helical Device are analysed for two plasma discharges. Absolute moment analysis is used to quantify properties on different temporal scales of the measured signals, which are bursty and intermittent. Strong coherent modes in some datasets are found to distort this analysis and are consequently removed from the time series by applying bandstop filters. Absolute moment analysis of the filtered data reveals two regions of power-law scaling, with the temporal scale τ ≈ 40 µs separating the two regimes. A comparison is made with similar results from the Mega-Amp Spherical Tokamak. The probability density function is studied and a monotonic relationship between connection length and skewness is found. Conditional averaging is used to characterize the average temporal shape of the largest intermittent bursts.

  13. Nearshore Satellite Data as Relative Indicators of Intertidal Organism Physiological Stress

    NASA Astrophysics Data System (ADS)

    Matzelle, A.; Helmuth, B.; Lakshmi, V.

    2011-12-01

    The physiological performance of intertidal and shallow subtidal invertebrates and algae is significantly affected by water temperature, and so the ability to measure and model onshore water temperatures is critical for ecological and biogeographic studies. Because of the localized influences of processes such as upwelling, mixing, and surface heating from solar radiation, nearshore water temperatures can differ from those measured directly offshore by buoys and satellites. It remains an open question what the magnitude of the differences in these temperatures are, and whether "large pixel" measurements can serve as an effective proxy for onshore processes, particularly when extrapolating from laboratory physiological studies to field conditions. We compared 9 years of nearshore (~10km) MODIS (Terra and Aqua overpasses) SST data against in situ measurements of water temperature conducted at two intertidal sites in central Oregon- Boiler Bay and Strawberry Hill. We collapsed data into increasingly longer temporal averages to address the correlation and absolute differences between onshore and nearshore temperatures over daily, weekly and monthly timescales. Results indicate that nearshore SST is a reasonable proxy for onshore water temperature, and that the strength of the correlation increases with decreasing temporal resolution. Correlations between differences in maxima are highest, followed by average and minima, and were lower at a site with regular upwelling. While average differences ranged from ~0.199-1.353°C, absolute differences across time scales were ~0.446-6.906°C, and were highest for cold temperatures. The results suggest that, at least at these two sites, SST can be used as a relative proxy for general trends only, especially over longer time scales.

  14. Moving beyond quiet stance: applicability of the inverted pendulum model to stooping and crouching postures.

    PubMed

    Weaver, Tyler B; Glinka, Michal N; Laing, Andrew C

    2014-11-07

    Currently, it is unknown whether the inverted pendulum model is applicable to stooping or crouching postures. Therefore, the aim of this study was to determine the degree of applicability of the inverted pendulum model to these postures, via examination of the relationship between the centre of mass (COM) acceleration and centre of pressure (COP)-COM difference. Ten young adults held static standing, stooping and crouching postures, each for 20s. For both the anterior-posterior (AP) and medio-lateral (ML) directions, the time-varying COM acceleration and the COP-COM were computed, and the relationship between these two variables was determined using Pearson's correlation coefficients. Additionally, in both directions, the average absolute COM acceleration, average absolute COP-COM signal, and the inertial component (i.e., -I/Wh) were compared across postures. Pearson correlation coefficients revealed a significant negative relationship between the COM acceleration and COP-COM signal for all comparisons, regardless of the direction (p<0.001). While no effect of posture was observed in the AP direction (p=0.463), in the ML direction, the correlation coefficients for stooping were different (i.e., stronger) than standing (p=0.008). Regardless of direction, the average absolute COM acceleration for both the stooping and crouching postures was greater than standing (p<0.002). The high correlations indicate that the inverted pendulum model is applicable to stooping and crouching postures. Due to their importance in completing activities of daily living, there is merit in determining what type of motor strategies are used to control such postures and whether these strategies change with age. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  15. Roadside increments in PM10, NOx and NO2 concentrations observed over 2 months at a major highway in New Zealand.

    PubMed

    Longley, Ian; Somervell, Elizabeth; Gray, Sally

    Continuous and simultaneous observational particulate matter (measured as PM 10 ), nitrogen dioxide (NO 2 ) and oxides of nitrogen (NO x ) data were captured at a kerbside site alongside a major highway in Auckland, New Zealand, and at a pair of setback sites within 250 m of the highway, day and night over 8 weeks. The three measurement sites were intended to allow emissions from the highway to be largely isolated from other sources. By filtering the data and subtracting upwind concentrations, the average roadside increment was calculated to be 1.8, 7.2 and 101.4 μg m -3 for PM 10 , NO 2 and NO x , respectively, relative to a predominantly upwind setback site, and -0.1, 9.4 and 98.5 μg m -3 for PM 10 , NO 2 and NO x , respectively, relative to a downwind setback site. The negative value for PM 10 was attributed to local evening heating sources impacting the setback site. On days when peak 24 h PM 10 concentrations were observed, the absolute kerbside increment was 2.1 μg m -3 . The absolute roadside 24 h average PM 10 increment varied diurnally, peaking (on average) at 2.4 μg m -3 during peak traffic hours. The largest observed 24-h average PM 10 roadside increment was 6.9 μg m -3 and exceeded 5 μg m -3 on nine occasions. On each of these occasions, the daily mean wind speed was less than 2 m s -1 . The diurnally averaged difference in NO x concentrations between the kerbside site and the setback sites clearly resembled the diurnal cycle in traffic volume, and peaked during the morning traffic peak at around 180 μg m -3 . Background NO x concentrations were slightly higher in our study compared to a similar study in Las Vegas but absolute roadside concentrations were higher. This may be consistent with higher NO x emission factors in Auckland, but differences in the precise distance of the monitor from the road lanes and differences in meteorology need to be considered.

  16. SU-C-BRA-02: Gradient Based Method of Target Delineation On PET/MR Image of Head and Neck Cancer Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dance, M; Chera, B; Falchook, A

    2015-06-15

    Purpose: Validate the consistency of a gradient-based segmentation tool to facilitate accurate delineation of PET/CT-based GTVs in head and neck cancers by comparing against hybrid PET/MR-derived GTV contours. Materials and Methods: A total of 18 head and neck target volumes (10 primary and 8 nodal) were retrospectively contoured using a gradient-based segmentation tool by two observers. Each observer independently contoured each target five times. Inter-observer variability was evaluated via absolute percent differences. Intra-observer variability was examined by percentage uncertainty. All target volumes were also contoured using the SUV percent threshold method. The thresholds were explored case by case so itsmore » derived volume matched with the gradient-based volume. Dice similarity coefficients (DSC) were calculated to determine overlap of PET/CT GTVs and PET/MR GTVs. Results: The Levene’s test showed there was no statistically significant difference of the variances between the observer’s gradient-derived contours. However, the absolute difference between the observer’s volumes was 10.83%, with a range from 0.39% up to 42.89%. PET-avid regions with qualitatively non-uniform shapes and intensity levels had a higher absolute percent difference near 25%, while regions with uniform shapes and intensity levels had an absolute percent difference of 2% between observers. The average percentage uncertainty between observers was 4.83% and 7%. As the volume of the gradient-derived contours increased, the SUV threshold percent needed to match the volume decreased. Dice coefficients showed good agreement of the PET/CT and PET/MR GTVs with an average DSC value across all volumes at 0.69. Conclusion: Gradient-based segmentation of PET volume showed good consistency in general but can vary considerably for non-uniform target shapes and intensity levels. PET/CT-derived GTV contours stemming from the gradient-based tool show good agreement with the anatomically and metabolically more accurate PET/MR-derived GTV contours, but tumor delineation accuracy can be further improved with the use PET/MR.« less

  17. Efficiency at Sorting Cards in Compressed Air

    PubMed Central

    Poulton, E. C.; Catton, M. J.; Carpenter, A.

    1964-01-01

    At a site where compressed air was being used in the construction of a tunnel, 34 men sorted cards twice, once at normal atmospheric pressure and once at 3½, 2½, or 2 atmospheres absolute pressure. An additional six men sorted cards twice at normal atmospheric pressure. When the task was carried out for the first time, all the groups of men performing at raised pressure were found to yield a reliably greater proportion of very slow responses than the group of men performing at normal pressure. There was reliably more variability in timing at 3½ and 2½ atmospheres absolute than at normal pressure. At 3½ atmospheres absolute the average performance was also reliably slower. When the task was carried out for the second time, exposure to 3½ atmospheres absolute pressure had no reliable effect. Thus compressed air affected performance only while the task was being learnt; it had little effect after practice. No reliable differences were found related to age, to length of experience in compressed air, or to the duration of the exposure to compressed air, which was never less than 10 minutes at 3½ atmospheres absolute pressure. PMID:14180485

  18. SU-F-T-76: Total Skin Electron Therapy: An-End-To-End Examination of the Absolute Dosimetry with a Rando Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cui, G; Ha, J; Zhou, S

    Purpose: To examine and validate the absolute dose for total skin electron therapy (TSET) through an end-to-end test with a Rando phantom using optically stimulated luminescent dosimeters (OSLDs) and EBT3 radiochromic films. Methods: A Varian Trilogy linear accelerator equipped with the special procedure 6 MeV HDTSe- was used to perform TSET irradiations using a modified Stanford 6-dual-field technique. The absolute dose was calibrated using a Markus ion chamber at a reference depth of 1.3cm at 100 cm SSD with a field size of 36 × 36 cm at the isocenter in solid water slabs. The absolute dose was cross validatedmore » by a farmer ion chamber. Then the dose rate in the unit of cGy/Mu was calibrated using the Markus chamber at the treatment position. OSLDs were used to independently verify the dose using the calibrated dose rate. Finally, a patient treatment plan (200 cGy/cycle) was delivered in the QA mode to a Rando phantom, which had 16 pairs of OSLDs and EBT3 films taped onto its surface at different anatomical positions. The doses recorded were read out to validate the absolute dosimetry for TSET. Results: The OSLD measurements were within 7% agreement with the planned dose except the shoulder areas, where the doses recorded were 23% lower on average than those of the planned. The EBT3 film measurements were within 10% agreement with the planned dose except the shoulder and the scalp vertex areas, where the respective doses recorded were 18% and 14% lower on average than those of the planned. The OSLDs gave more consistent dose measurements than those of the EBT3 films. Conclusion: The absolute dosimetry for TSET was validated by an end-to-end test with a Rando phantom using the OSLDs and EBT3 films. The beam calibration and monitor unit calculations were confirmed.« less

  19. Patients with Rheumatoid Arthritis and Chronic Pain Display Enhanced Alpha Power Density at Rest.

    PubMed

    Meneses, Francisco M; Queirós, Fernanda C; Montoya, Pedro; Miranda, José G V; Dubois-Mendes, Selena M; Sá, Katia N; Luz-Santos, Cleber; Baptista, Abrahão F

    2016-01-01

    Patients with chronic pain due to neuropathy or musculoskeletal injury frequently exhibit reduced alpha and increased theta power densities. However, little is known about electrical brain activity and chronic pain in patients with rheumatoid arthritis (RA). For this purpose, we evaluated power densities of spontaneous electroencephalogram (EEG) band frequencies (delta, theta, alpha, and beta) in females with persistent pain due to RA. This was a cross-sectional study of 21 participants with RA and 21 healthy controls (mean age = 47.20; SD = 10.40). EEG was recorded at rest over 5 min with participant's eyes closed. Twenty electrodes were placed over five brain regions (frontal, central, parietal, temporal, and occipital). Significant differences were observed in depression and anxiety with higher scores in RA participants than healthy controls (p = 0.002). Participants with RA exhibited increased average absolute alpha power density in all brain regions when compared to controls [F (1.39) = 6.39, p = 0.016], as well as increased average relative alpha power density [F (1.39) = 5.82, p = 0.021] in all regions, except the frontal region, controlling for depression/anxiety. Absolute theta power density also increased in the frontal, central, and parietal regions for participants with RA when compared to controls [F (1, 39) = 4.51, p = 0.040], controlling for depression/anxiety. Differences were not exhibited on beta and delta absolute and relative power densities. The diffuse increased alpha may suggest a possible neurogenic mechanism for chronic pain in individuals with RA.

  20. Validation of the CrIS fast physical NH3 retrieval with ground-based FTIR

    NASA Astrophysics Data System (ADS)

    Dammers, Enrico; Shephard, Mark W.; Palm, Mathias; Cady-Pereira, Karen; Capps, Shannon; Lutsch, Erik; Strong, Kim; Hannigan, James W.; Ortega, Ivan; Toon, Geoffrey C.; Stremme, Wolfgang; Grutter, Michel; Jones, Nicholas; Smale, Dan; Siemons, Jacob; Hrpcek, Kevin; Tremblay, Denis; Schaap, Martijn; Notholt, Justus; Erisman, Jan Willem

    2017-07-01

    Presented here is the validation of the CrIS (Cross-track Infrared Sounder) fast physical NH3 retrieval (CFPR) column and profile measurements using ground-based Fourier transform infrared (FTIR) observations. We use the total columns and profiles from seven FTIR sites in the Network for the Detection of Atmospheric Composition Change (NDACC) to validate the satellite data products. The overall FTIR and CrIS total columns have a positive correlation of r = 0.77 (N = 218) with very little bias (a slope of 1.02). Binning the comparisons by total column amounts, for concentrations larger than 1.0 × 1016 molecules cm-2, i.e. ranging from moderate to polluted conditions, the relative difference is on average ˜ 0-5 % with a standard deviation of 25-50 %, which is comparable to the estimated retrieval uncertainties in both CrIS and the FTIR. For the smallest total column range (< 1.0 × 1016 molecules cm-2) where there are a large number of observations at or near the CrIS noise level (detection limit) the absolute differences between CrIS and the FTIR total columns show a slight positive column bias. The CrIS and FTIR profile comparison differences are mostly within the range of the single-level retrieved profile values from estimated retrieval uncertainties, showing average differences in the range of ˜ 20 to 40 %. The CrIS retrievals typically show good vertical sensitivity down into the boundary layer which typically peaks at ˜ 850 hPa (˜ 1.5 km). At this level the median absolute difference is 0.87 (std = ±0.08) ppb, corresponding to a median relative difference of 39 % (std = ±2 %). Most of the absolute and relative profile comparison differences are in the range of the estimated retrieval uncertainties. At the surface, where CrIS typically has lower sensitivity, it tends to overestimate in low-concentration conditions and underestimate in higher atmospheric concentration conditions.

  1. Absolute calibration accuracy of L4 TM and L5 TM sensor image pairs

    USGS Publications Warehouse

    Chander, G.; Micijevic, E.

    2006-01-01

    The Landsat suite of satellites has collected the longest continuous archive of multispectral data of any land-observing space program. From the Landsat program's inception in 1972 to the present, the Earth science user community has benefited from a historical record of remotely sensed data. However, little attention has been paid to ensuring that the data are calibrated and comparable from mission to mission, Launched in 1982 and 1984 respectively, the Landsat 4 (L4) and Landsat 5 (L5) Thematic Mappers (TM) are the backbone of an extensive archive of moderate resolution Earth imagery. To evaluate the "current" absolute accuracy of these two sensors, image pairs from the L5 TM and L4 TM sensors were compared. The approach involves comparing image statistics derived from large common areas observed eight days apart by the two sensors. The average percent differences in reflectance estimates obtained from the L4 TM agree with those from the L5 TM to within 15 percent. Additional work to characterize the absolute differences between the two sensors over the entire mission is in progress.

  2. Geographical trends in infant mortality: England and Wales, 1970-2006.

    PubMed

    Norman, Paul; Gregory, Ian; Dorling, Danny; Baker, Allan

    2008-01-01

    At national level in England and Wales, infant mortality rates fell rapidly from the early 1970s and into the 1980s. Subnational areas have also experienced a reduction in levels of infant mortality. While rates continued to fall to 2006, the rate of reduction has slowed. Although the Government Office Regions Yorkshire and The Humber, the North West and the West Midlands and the Office for National Statistics local authority types Cities and Services and London Cosmopolitan have experienced relatively large absolute reductions in infant mortality, their rates remained high compared with the national average. Within all regions and local authority types, a strong relationship was found between ward level deprivation and infant mortality rates. Nevertheless, levels of infant mortality declined over time even in the most deprived areas with a narrowing of absolute differences in rates between areas. Areas in which the level of deprivation eased have experienced greater than average reductions in levels of infant mortality.

  3. National mortality rates: the impact of inequality?

    PubMed

    Wilkinson, R G

    1992-08-01

    Although health is closely associated with income differences within each country there is, at best, only a weak link between national mortality rates and average income among the developed countries. On the other hand, there is evidence of a strong relationship between national mortality rates and the scale of income differences within each society. These three elements are coherent if health is affected less by changes in absolute material standards across affluent populations than it is by relative income or the scale of income differences and the resulting sense of disadvantage within each society. Rather than socioeconomic mortality differentials representing a distribution around given national average mortality rates, it is likely that the degree of income inequality indicates the burden of relative deprivation on national mortality rates.

  4. The major influence of the atmosphere on intracranial pressure: an observational study.

    PubMed

    Herbowski, Leszek

    2017-01-01

    The impact of the atmosphere on human physiology has been studied widely within the last years. In practice, intracranial pressure is a pressure difference between intracranial compartments and the surrounding atmosphere. This means that gauge intracranial pressure uses atmospheric pressure as its zero point, and therefore, this method of pressure measurement excludes the effects of barometric pressure's fluctuation. The comparison of these two physical quantities can only take place through their absolute value relationship. The aim of this study is to investigate the direct effect of barometric pressure on the absolute intracranial pressure homeostasis. A prospective observational cross-sectional open study was conducted in Szczecin, Poland. In 28 neurosurgical patients with suspected normal-pressure hydrocephalus, intracranial intraventricular pressure was monitored in a sitting position. A total of 168 intracranial pressure and atmospheric pressure measurements were performed. Absolute atmospheric pressure was recorded directly. All values of intracranial gauge pressure were converted to absolute pressure (the sum of gauge intracranial pressure and local absolute atmospheric pressure). The average absolute mean intracranial pressure in the patients is 1006.6 hPa (95 % CI 1004.5 to 1008.8 hPa, SEM 1.1), and the mean absolute atmospheric pressure is 1007.9 hPa (95 % CI 1006.3 to 1009.6 hPa, SEM 0.8). The observed association between atmospheric and intracranial pressure is strongly significant (Spearman correlation r = 0.87, p < 0.05) and all the measurements are perfectly reliable (Bland-Altman coefficient is 4.8 %). It appears from this study that changes in absolute intracranial pressure are related to seasonal variation. Absolute intracranial pressure is shown to be impacted positively by atmospheric pressure.

  5. The major influence of the atmosphere on intracranial pressure: an observational study

    NASA Astrophysics Data System (ADS)

    Herbowski, Leszek

    2017-01-01

    The impact of the atmosphere on human physiology has been studied widely within the last years. In practice, intracranial pressure is a pressure difference between intracranial compartments and the surrounding atmosphere. This means that gauge intracranial pressure uses atmospheric pressure as its zero point, and therefore, this method of pressure measurement excludes the effects of barometric pressure's fluctuation. The comparison of these two physical quantities can only take place through their absolute value relationship. The aim of this study is to investigate the direct effect of barometric pressure on the absolute intracranial pressure homeostasis. A prospective observational cross-sectional open study was conducted in Szczecin, Poland. In 28 neurosurgical patients with suspected normal-pressure hydrocephalus, intracranial intraventricular pressure was monitored in a sitting position. A total of 168 intracranial pressure and atmospheric pressure measurements were performed. Absolute atmospheric pressure was recorded directly. All values of intracranial gauge pressure were converted to absolute pressure (the sum of gauge intracranial pressure and local absolute atmospheric pressure). The average absolute mean intracranial pressure in the patients is 1006.6 hPa (95 % CI 1004.5 to 1008.8 hPa, SEM 1.1), and the mean absolute atmospheric pressure is 1007.9 hPa (95 % CI 1006.3 to 1009.6 hPa, SEM 0.8). The observed association between atmospheric and intracranial pressure is strongly significant (Spearman correlation r = 0.87, p < 0.05) and all the measurements are perfectly reliable (Bland-Altman coefficient is 4.8 %). It appears from this study that changes in absolute intracranial pressure are related to seasonal variation. Absolute intracranial pressure is shown to be impacted positively by atmospheric pressure.

  6. Volumetric vessel reconstruction method for absolute blood flow velocity measurement in Doppler OCT images

    NASA Astrophysics Data System (ADS)

    Qi, Li; Zhu, Jiang; Hancock, Aneeka M.; Dai, Cuixia; Zhang, Xuping; Frostig, Ron D.; Chen, Zhongping

    2017-02-01

    Doppler optical coherence tomography (DOCT) is considered one of the most promising functional imaging modalities for neuro biology research and has demonstrated the ability to quantify cerebral blood flow velocity at a high accuracy. However, the measurement of total absolute blood flow velocity (BFV) of major cerebral arteries is still a difficult problem since it not only relates to the properties of the laser and the scattering particles, but also relates to the geometry of both directions of the laser beam and the flow. In this paper, focusing on the analysis of cerebral hemodynamics, we presents a method to quantify the total absolute blood flow velocity in middle cerebral artery (MCA) based on volumetric vessel reconstruction from pure DOCT images. A modified region growing segmentation method is first used to localize the MCA on successive DOCT B-scan images. Vessel skeletonization, followed by an averaging gradient angle calculation method, is then carried out to obtain Doppler angles along the entire MCA. Once the Doppler angles are determined, the absolute blood flow velocity of each position on the MCA is easily found. Given a seed point position on the MCA, our approach could achieve automatic quantification of the fully distributed absolute BFV. Based on experiments conducted using a swept-source optical coherence tomography system, our approach could achieve automatic quantification of the fully distributed absolute BFV across different vessel branches in the rodent brain.

  7. Changes in product recovery between live and dead lodgepole pine: a compendium.

    Treesearch

    Thomas D. Fahey; Thomas A. Snellgrove; Marlin E. Plank

    1986-01-01

    Six studies were used to compare differences in recovery of volume and value among live, recent dead, and older dead lodgepole pine (Pinus contorts Dougl. ex Loud.) in the Western United States. The products studied included boards, random-length dimension, studs, and veneer. For the average size log (12 cubic feet) absolute values were highest for boards, followed by...

  8. Cross-Regional Differences in Meeting the Challenge of Teacher Salary Increase

    ERIC Educational Resources Information Center

    Derkachev, P. V.

    2015-01-01

    This paper presents an overview of studies on the correlations of teacher pay to regional economics and to regional factors affecting the size of teacher salaries. It describes the basic pay indicators for teachers in the regions: absolute salary, teacher pay level as compared to the average regional salary, and ratio of salary to the cost of a…

  9. Comparative analysis of operational forecasts versus actual weather conditions in airline flight planning, volume 3

    NASA Technical Reports Server (NTRS)

    Keitz, J. F.

    1982-01-01

    The impact of more timely and accurate weather data on airline flight planning with the emphasis on fuel savings is studied. This volume of the report discusses the results of Task 3 of the four major tasks included in the study. Task 3 compares flight plans developed on the Suitland forecast with actual data observed by the aircraft (and averaged over 10 degree segments). The results show that the average difference between the forecast and observed wind speed is 9 kts. without considering direction, and the average difference in the component of the forecast wind parallel to the direction of the observed wind is 13 kts. - both indicating that the Suitland forecast underestimates the wind speeds. The Root Mean Square (RMS) vector error is 30.1 kts. The average absolute difference in direction between the forecast and observed wind is 26 degrees and the temperature difference is 3 degree Centigrade. These results indicate that the forecast model as well as the verifying analysis used to develop comparison flight plans in Tasks 1 and 2 is a limiting factor and that the average potential fuel savings or penalty are up to 3.6 percent depending on the direction of flight.

  10. Standard and reduced doses of dabigatran, rivaroxaban and apixaban for stroke prevention in atrial fibrillation: a nationwide cohort study.

    PubMed

    Staerk, L; Gerds, T A; Lip, G Y H; Ozenne, B; Bonde, A N; Lamberts, M; Fosbøl, E L; Torp-Pedersen, C; Gislason, G H; Olesen, J B

    2018-01-01

    Comparative data of non-vitamin K antagonist oral anticoagulants (NOAC) are lacking in patients with atrial fibrillation (AF). We compared effectiveness and safety of standard and reduced dose NOAC in AF patients. Using Danish nationwide registries, we included all oral anticoagulant-naïve AF patients who initiated NOAC treatment (2012-2016). Outcome-specific and mortality-specific multiple Cox regressions were combined to compute average treatment effects as 1-year standardized differences in stroke and bleeding risks (g-formula). Amongst 31 522 AF patients, the distribution of NOAC/dose was as follows: dabigatran standard dose (22.4%), dabigatran-reduced dose (14.0%), rivaroxaban standard dose (21.8%), rivaroxaban reduced dose (6.7%), apixaban standard dose (22.9%), and apixaban reduced dose (12.2%). The 1-year standardized absolute risks of stroke/thromboembolism were 1.73-1.98% and 2.51-2.78% with standard and reduced NOAC dose, respectively, without statistically significant differences between NOACs for given dose level. Comparing standard doses, the 1-year standardized absolute risk (95% CI) for major bleeding was for rivaroxaban 2.78% (2.42-3.17%); corresponding absolute risk differences (95% CI) were for dabigatran -0.93% (-1.45% to -0.38%) and apixaban, -0.54% (-0.99% to -0.05%). The results for major bleeding were similar for reduced NOAC dose. The 1-year standardized absolute risk (95% CI) for intracranial bleeding was for standard dose dabigatran 0.19% (0.22-0.50%); corresponding absolute risk differences (95% CI) were for rivaroxaban 0.23% (0.06-0.41%) and apixaban, 0.18% (0.01-0.34%). Standard and reduced dose NOACs, respectively, showed no significant risk difference for associated stroke/thromboembolism. Rivaroxaban was associated with higher bleeding risk compared with dabigatran and apixaban and dabigatran was associated with lower intracranial bleeding risk compared with rivaroxaban and apixaban. © 2017 The Association for the Publication of the Journal of Internal Medicine.

  11. Debiased orbit and absolute-magnitude distributions for near-Earth objects

    NASA Astrophysics Data System (ADS)

    Granvik, Mikael; Morbidelli, Alessandro; Jedicke, Robert; Bolin, Bryce; Bottke, William F.; Beshore, Edward; Vokrouhlický, David; Nesvorný, David; Michel, Patrick

    2018-09-01

    The debiased absolute-magnitude and orbit distributions as well as source regions for near-Earth objects (NEOs) provide a fundamental frame of reference for studies of individual NEOs and more complex population-level questions. We present a new four-dimensional model of the NEO population that describes debiased steady-state distributions of semimajor axis, eccentricity, inclination, and absolute magnitude H in the range 17 < H < 25. The modeling approach improves upon the methodology originally developed by Bottke et al. (2000, Science 288, 2190-2194) in that it is, for example, based on more realistic orbit distributions and uses source-specific absolute-magnitude distributions that allow for a power-law slope that varies with H. We divide the main asteroid belt into six different entrance routes or regions (ER) to the NEO region: the ν6, 3:1J, 5:2J and 2:1J resonance complexes as well as Hungarias and Phocaeas. In addition we include the Jupiter-family comets as the primary cometary source of NEOs. We calibrate the model against NEO detections by Catalina Sky Surveys' stations 703 and G96 during 2005-2012, and utilize the complementary nature of these two systems to quantify the systematic uncertainties associated to the resulting model. We find that the (fitted) H distributions have significant differences, although most of them show a minimum power-law slope at H ∼ 20. As a consequence of the differences between the ER-specific H distributions we find significant variations in, for example, the NEO orbit distribution, average lifetime, and the relative contribution of different ERs as a function of H. The most important ERs are the ν6 and 3:1J resonance complexes with JFCs contributing a few percent of NEOs on average. A significant contribution from the Hungaria group leads to notable changes compared to the predictions by Bottke et al. in, for example, the orbit distribution and average lifetime of NEOs. We predict that there are 962-56+52 (802-42+48 ×103) NEOs with H < 17.75 (H < 25) and these numbers are in agreement with the most recent estimates found in the literature (the uncertainty estimates only account for the random component). Based on our model we find that relative shares between different NEO groups (Amor, Apollo, Aten, Atira, Vatira) are (39.4,54.4,3.5,1.2,0.3)%, respectively, for the considered H range and that these ratios have a negligible dependence on H. Finally, we find an agreement between our estimate for the rate of Earth impacts by NEOs and recent estimates in the literature, but there remains a potentially significant discrepancy in the frequency of Tunguska-sized and Chelyabinsk-sized impacts.

  12. Absolute Sea-level Changes Derived from Integrated Geodetic Datasets (1955-2016) in the Caribbean Sea

    NASA Astrophysics Data System (ADS)

    Yang, L.; Wang, G.; Liu, H.

    2017-12-01

    Rising sea level has important direct impacts on coastal and island regions such as the Caribbean where the influence of sea-level rise is becoming more apparent. The Caribbean Sea is a semi-enclosed sea adjacent to the landmasses of South and Central America to the south and west, and the Greater Antilles and the Lesser Antilles separate it from the Atlantic Ocean to the north and east. The work focus on studying the relative and absolute sea-level changes by integrating tide gauge, GPS, and satellite altimetry datasets (1955-2016) within the Caribbean Sea. Further, the two main components of absolute sea-level change, ocean mass and steric sea-level changes, are respectively studied using GRACE, temperature, and salinity datasets (1955-2016). According to the analysis conducted, the sea-level change rates have considerable temporal and spatial variations, and estimates may be subject to the techniques used and observation periods. The average absolute sea-level rise rate is 1.8±0.3 mm/year for the period from 1955 to 2015 according to the integrated tide gauge and GPS observations; the average absolute sea-level rise rate is 3.5±0.6 mm/year for the period from 1993 to 2016 according to the satellite altimetry observations. This study shows that the absolute sea-level change budget in the Caribbean Sea is closed in the periods from 1955 to 2016, in which ocean mass change dominates the absolute sea-level rise. The absolute sea-level change budget is also closed in the periods from 2004 to 2016, in which steric sea-level rise dominates the absolute sea-level rise.

  13. Predicting Accommodative Response Using Paraxial Schematic Eye Models

    PubMed Central

    Ramasubramanian, Viswanathan; Glasser, Adrian

    2016-01-01

    Purpose Prior ultrasound biomicroscopy (UBM) studies showed that accommodative optical response (AOR) can be predicted from accommodative biometric changes in a young and a pre-presbyopic population from linear relationships between accommodative optical and biometric changes, with a standard deviation of less than 0.55D. Here, paraxial schematic eyes (SE) were constructed from measured accommodative ocular biometry parameters to see if predictions are improved. Methods Measured ocular biometry (OCT, A-scan and UBM) parameters from 24 young and 24 pre-presbyopic subjects were used to construct paraxial SEs for each individual subject (individual SEs) for three different lens equivalent refractive index methods. Refraction and AOR calculated from the individual SEs were compared with Grand Seiko (GS) autorefractor measured refraction and AOR. Refraction and AOR were also calculated from individual SEs constructed using the average population accommodative change in UBM measured parameters (average SEs). Results Schematic eye calculated and GS measured AOR were linearly related (young subjects: slope = 0.77; r2 = 0.86; pre-presbyopic subjects: slope = 0.64; r2 = 0.55). The mean difference in AOR (GS - individual SEs) for the young subjects was −0.27D and for the pre-presbyopic subjects was 0.33D. For individual SEs, the mean ± SD of the absolute differences in AOR between the GS and SEs was 0.50 ± 0.39D for the young subjects and 0.50 ± 0.37D for the pre-presbyopic subjects. For average SEs, the mean ± SD of the absolute differences in AOR between the GS and the SEs was 0.77 ± 0.88D for the young subjects and 0.51 ± 0.49D for the pre-presbyopic subjects. Conclusions Individual paraxial SEs predict AOR, on average, with a standard deviation of 0.50D in young and pre-presbyopic subject populations. Although this prediction is only marginally better than from individual linear regressions, it does consider all the ocular biometric parameters. PMID:27092928

  14. Concordance of the location of the innervation zone of the tibialis anterior muscle using voluntary and imposed contractions by electrostimulation.

    PubMed

    Guzmán-Venegas, R A; Bralic, M P; Cordero, J J; Cavada, G; Araneda, O F

    2016-04-01

    The innervation zone (IZ) corresponds to the location of the neuromuscular junctions. Its location can be determined by using arranged surface linear electrode arrays. Typically, voluntary muscle contractions (VC) are used in this method. However, it also may be necessary to locate the IZ under clinical conditions such as spasticity, in which this type of contraction is difficult to perform. Therefore, contractions imposed by electrostimulation (ES) can be an alternative. There is little background comparing the locations of IZ obtained by two different types of contractions. Evaluate the concordance between using voluntary and imposed contractions from electrostimulation in order to determine the location of the innervation zone of the tibialis anterior muscle in healthy volunteers. The tibialis anterior (TA) muscle of sixteen volunteers (men: 8; women: 8; age: 22.1±1.4years, weight: 61.6±7.5kg, height: 167.1±7.5cm) were evaluated using a linear electrode array. The IZ of the TA muscle was located using two types of muscle contractions, voluntary (10% MVC) and imposed contractions by ES. The concordance between both conditions was evaluated using the Bland-Altman method and the concordance correlation coefficient (CCC). The analyses were applied to the absolute and relative positions to the length of an anatomical landmark frame. CCC for absolute position was 0.98 (p<0.0001, 95% CI [0.98-1.00], and CCC for relative positions also was 0.98 (p<0.0001, 95% CI [0.97-1.00]). The Bland-Altman analysis for absolute data showed an average difference of -0.63mm (SD: 4.1). Whereas, for adjusted data, the average difference was -0.20% (SD: 1.2). The power of the results, based on absolute data, was 98%, whereas for relative data, 82%. In healthy volunteers, there was a substantially concordance between the location of the IZ of the TA muscle derived from using contractions imposed by ES and the location derived from using VC. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Do patients with OAB experience bladder sensations in the same way as healthy volunteers? A focus group investigation.

    PubMed

    Heeringa, R; van Koeveringe, G A; Winkens, B; van Kerrebroeck, P E V; de Wachter, S G G

    2012-04-01

    To describe the terminology and pattern of bladder sensations experienced during non-invasive rapid bladder filling in a controlled setting in patients with OAB and to compare these results with a previous study conducted in healthy volunteers. Three groups of patients with OAB, in total 10 patients, participated in three consecutive focus group sessions. Before each session a strict water loading protocol was given. During the first two sessions, participants described how they experienced their bladder sensations in daily life and during a non-invasive bladder filling with constant focus on their bladder. The third session focused on verifying the interpretation of the data gathered and describing the pattern of sensations. Patients describe their bladder sensations as a pressure or a tingling sensation and the pattern can be described by terms ranging from no sensation to an absolute need to void. The absolute need to void may develop suddenly or more slowly progressive. The mean development of bladder sensation is significantly different between patients and healthy volunteers as well as their average diuresis. Patients with OAB describe their bladder sensations as a pressure or a tingling sensation. There appear to be two types of urgency: a sudden absolute need to void and a slowly developing absolute need to void. Furthermore bladder sensation develops significantly different in volunteers than in OAB patients. Copyright © 2012 Wiley Periodicals, Inc.

  16. National mortality rates: the impact of inequality?

    PubMed Central

    Wilkinson, R G

    1992-01-01

    Although health is closely associated with income differences within each country there is, at best, only a weak link between national mortality rates and average income among the developed countries. On the other hand, there is evidence of a strong relationship between national mortality rates and the scale of income differences within each society. These three elements are coherent if health is affected less by changes in absolute material standards across affluent populations than it is by relative income or the scale of income differences and the resulting sense of disadvantage within each society. Rather than socioeconomic mortality differentials representing a distribution around given national average mortality rates, it is likely that the degree of income inequality indicates the burden of relative deprivation on national mortality rates. PMID:1636827

  17. Experimental verification of a commercial Monte Carlo-based dose calculation module for high-energy photon beams.

    PubMed

    Künzler, Thomas; Fotina, Irina; Stock, Markus; Georg, Dietmar

    2009-12-21

    The dosimetric performance of a Monte Carlo algorithm as implemented in a commercial treatment planning system (iPlan, BrainLAB) was investigated. After commissioning and basic beam data tests in homogenous phantoms, a variety of single regular beams and clinical field arrangements were tested in heterogeneous conditions (conformal therapy, arc therapy and intensity-modulated radiotherapy including simultaneous integrated boosts). More specifically, a cork phantom containing a concave-shaped target was designed to challenge the Monte Carlo algorithm in more complex treatment cases. All test irradiations were performed on an Elekta linac providing 6, 10 and 18 MV photon beams. Absolute and relative dose measurements were performed with ion chambers and near tissue equivalent radiochromic films which were placed within a transverse plane of the cork phantom. For simple fields, a 1D gamma (gamma) procedure with a 2% dose difference and a 2 mm distance to agreement (DTA) was applied to depth dose curves, as well as to inplane and crossplane profiles. The average gamma value was 0.21 for all energies of simple test cases. For depth dose curves in asymmetric beams similar gamma results as for symmetric beams were obtained. Simple regular fields showed excellent absolute dosimetric agreement to measurement values with a dose difference of 0.1% +/- 0.9% (1 standard deviation) at the dose prescription point. A more detailed analysis at tissue interfaces revealed dose discrepancies of 2.9% for an 18 MV energy 10 x 10 cm(2) field at the first density interface from tissue to lung equivalent material. Small fields (2 x 2 cm(2)) have their largest discrepancy in the re-build-up at the second interface (from lung to tissue equivalent material), with a local dose difference of about 9% and a DTA of 1.1 mm for 18 MV. Conformal field arrangements, arc therapy, as well as IMRT beams and simultaneous integrated boosts were in good agreement with absolute dose measurements in the heterogeneous phantom. For the clinical test cases, the average dose discrepancy was 0.5% +/- 1.1%. Relative dose investigations of the transverse plane for clinical beam arrangements were performed with a 2D gamma-evaluation procedure. For 3% dose difference and 3 mm DTA criteria, the average value for gamma(>1) was 4.7% +/- 3.7%, the average gamma(1%) value was 1.19 +/- 0.16 and the mean 2D gamma-value was 0.44 +/- 0.07 in the heterogeneous phantom. The iPlan MC algorithm leads to accurate dosimetric results under clinical test conditions.

  18. Neural network versus classical time series forecasting models

    NASA Astrophysics Data System (ADS)

    Nor, Maria Elena; Safuan, Hamizah Mohd; Shab, Noorzehan Fazahiyah Md; Asrul, Mohd; Abdullah, Affendi; Mohamad, Nurul Asmaa Izzati; Lee, Muhammad Hisyam

    2017-05-01

    Artificial neural network (ANN) has advantage in time series forecasting as it has potential to solve complex forecasting problems. This is because ANN is data driven approach which able to be trained to map past values of a time series. In this study the forecast performance between neural network and classical time series forecasting method namely seasonal autoregressive integrated moving average models was being compared by utilizing gold price data. Moreover, the effect of different data preprocessing on the forecast performance of neural network being examined. The forecast accuracy was evaluated using mean absolute deviation, root mean square error and mean absolute percentage error. It was found that ANN produced the most accurate forecast when Box-Cox transformation was used as data preprocessing.

  19. Defining the Molecular Actions of Dietary Fatty Acids in Breast Cancer: Selective Modulation of Peroxisome Proliferator-Activated Receptor Gamma. Addendum

    DTIC Science & Technology

    2008-05-01

    0.05 significance threshold. Fol- owing ANOVA, Fisher’s least significant difference, LSD , air-wise comparison was implemented post-hoc. Briefly, the SD...average absolute difference etween any two groups was greater than the LSD critical alue, then the pair-wise comparison for those two groups ere...Xu, Y., Hin- shaw , J.C., Zimmerman, G.A., Hama, K., Aoki, J., Arai, H., Prestwich, G.D., 2003. Identification of an intracellular receptor for

  20. Communicating data about the benefits and harms of treatment: a randomized trial.

    PubMed

    Woloshin, Steven; Schwartz, Lisa M

    2011-07-19

    Despite limited evidence, it is often asserted that natural frequencies (for example, 2 in 1000) are the best way to communicate absolute risks. To compare comprehension of treatment benefit and harm when absolute risks are presented as natural frequencies, percents, or both. Parallel-group randomized trial with central allocation and masking of investigators to group assignment, conducted through an Internet survey in September 2009. (ClinicalTrials.gov registration number: NCT00950014) National sample of U.S. adults randomly selected from a professional survey firm's research panel of about 30,000 households. 2944 adults aged 18 years or older (all with complete follow-up). Tables presenting absolute risks in 1 of 5 numeric formats: natural frequency (x in 1000), variable frequency (x in 100, x in 1000, or x in 10,000, as needed to keep the numerator >1), percent, percent plus natural frequency, or percent plus variable frequency. Comprehension as assessed by 18 questions (primary outcome) and judgment of treatment benefit and harm. The average number of comprehension questions answered correctly was lowest in the variable frequency group and highest in the percent group (13.1 vs. 13.8; difference, 0.7 [95% CI, 0.3 to 1.1]). The proportion of participants who "passed" the comprehension test (≥13 correct answers) was lowest in the natural and variable frequency groups and highest in the percent group (68% vs. 73%; difference, 5 percentage points [CI, 0 to 10 percentage points]). The largest format effect was seen for the 2 questions about absolute differences: the proportion correct in the natural frequency versus percent groups was 43% versus 72% (P < 0.001) and 73% versus 87% (P < 0.001). Even when data were presented in the percent format, one third of participants failed the comprehension test. Natural frequencies are not the best format for communicating the absolute benefits and harms of treatment. The more succinct percent format resulted in better comprehension: Comprehension was slightly better overall and notably better for absolute differences. Attorney General Consumer and Prescriber Education grant program, the Robert Wood Johnson Pioneer Program, and the National Cancer Institute.

  1. Relative and Absolute Availability of Healthier Food and Beverage Alternatives Across Communities in the United States

    PubMed Central

    Powell, Lisa M.; Rimkus, Leah; Isgor, Zeynep; Barker, Dianne C.; Ohri-Vachaspati, Punam; Chaloupka, Frank

    2014-01-01

    Objectives. We examined associations between the relative and absolute availability of healthier food and beverage alternatives at food stores and community racial/ethnic, socioeconomic, and urban–rural characteristics. Methods. We analyzed pooled, annual cross-sectional data collected in 2010 to 2012 from 8462 food stores in 468 communities spanning 46 US states. Relative availability was the ratio of 7 healthier products (e.g., whole-wheat bread) to less healthy counterparts (e.g., white bread); we based absolute availability on the 7 healthier products. Results. The mean healthier food and beverage ratio was 0.71, indicating that stores averaged 29% fewer healthier than less healthy products. Lower relative availability of healthier alternatives was associated with low-income, Black, and Hispanic communities. Small stores had the largest differences: relative availability of healthier alternatives was 0.61 and 0.60, respectively, for very low-income Black and very low-income Hispanic communities, and 0.74 for very high-income White communities. We found fewer associations between absolute availability of healthier products and community characteristics. Conclusions. Policies to improve the relative availability of healthier alternatives may be needed to improve population health and reduce disparities. PMID:25211721

  2. Accuracy of free energies of hydration using CM1 and CM3 atomic charges.

    PubMed

    Udier-Blagović, Marina; Morales De Tirado, Patricia; Pearlman, Shoshannah A; Jorgensen, William L

    2004-08-01

    Absolute free energies of hydration (DeltaGhyd) have been computed for 25 diverse organic molecules using partial atomic charges derived from AM1 and PM3 wave functions via the CM1 and CM3 procedures of Cramer, Truhlar, and coworkers. Comparisons are made with results using charges fit to the electrostatic potential surface (EPS) from ab initio 6-31G* wave functions and from the OPLS-AA force field. OPLS Lennard-Jones parameters for the organic molecules were used together with the TIP4P water model in Monte Carlo simulations with free energy perturbation theory. Absolute free energies of hydration were computed for OPLS united-atom and all-atom methane by annihilating the solutes in water and in the gas phase, and absolute DeltaGhyd values for all other molecules were computed via transformation to one of these references. Optimal charge scaling factors were determined by minimizing the unsigned average error between experimental and calculated hydration free energies. The PM3-based charge models do not lead to lower average errors than obtained with the EPS charges for the subset of 13 molecules in the original study. However, improvement is obtained by scaling the CM1A partial charges by 1.14 and the CM3A charges by 1.15, which leads to average errors of 1.0 and 1.1 kcal/mol for the full set of 25 molecules. The scaled CM1A charges also yield the best results for the hydration of amides including the E/Z free-energy difference for N-methylacetamide in water. Copyright 2004 Wiley Periodicals, Inc.

  3. Measuring radio-signal power accurately

    NASA Technical Reports Server (NTRS)

    Goldstein, R. M.; Newton, J. W.; Winkelstein, R. A.

    1979-01-01

    Absolute value of signal power in weak radio signals is determined by computer-aided measurements. Equipment operates by averaging received signal over several-minute period and comparing average value with noise level of receiver previously calibrated.

  4. Towards a standard for the dynamic measurement of pressure based on laser absorption spectroscopy

    PubMed Central

    Douglass, K O; Olson, D A

    2016-01-01

    We describe an approach for creating a standard for the dynamic measurement of pressure based on the measurement of fundamental quantum properties of molecular systems. From the linewidth and intensities of ro-vibrational transitions we plan on making an accurate determination of pressure and temperature. The goal is to achieve an absolute uncertainty for time-varying pressure of 5 % with a measurement rate of 100 kHz, which will in the future serve as a method for the traceable calibration of pressure sensors used in transient processes. To illustrate this concept we have used wavelength modulation spectroscopy (WMS), due to inherent advantages over direct absorption spectroscopy, to perform rapid measurements of carbon dioxide in order to determine the pressure. The system records the full lineshape profile of a single ro-vibrational transition of CO2 at a repetition rate of 4 kHz and with a systematic measurement uncertainty of 12 % for the linewidth measurement. A series of pressures were measured at a rate of 400 Hz (10 averages) and from these measurements the linewidth was determined with a relative uncertainty of about 0.5 % on average. The pressures measured using WMS have an average difference of 0.6 % from the absolute pressure measured with a capacitance diaphragm sensor. PMID:27881884

  5. Pure-tone audiometry outside a sound booth using earphone attentuation, integrated noise monitoring, and automation.

    PubMed

    Swanepoel, De Wet; Matthysen, Cornelia; Eikelboom, Robert H; Clark, Jackie L; Hall, James W

    2015-01-01

    Accessibility of audiometry is hindered by the cost of sound booths and shortage of hearing health personnel. This study investigated the validity of an automated mobile diagnostic audiometer with increased attenuation and real-time noise monitoring for clinical testing outside a sound booth. Attenuation characteristics and reference ambient noise levels for the computer-based audiometer (KUDUwave) was evaluated alongside the validity of environmental noise monitoring. Clinical validity was determined by comparing air- and bone-conduction thresholds obtained inside and outside the sound booth (23 subjects). Twenty-three normal-hearing subjects (age range, 20-75 years; average age 35.5) and a sub group of 11 subjects to establish test-retest reliability. Improved passive attenuation and valid environmental noise monitoring was demonstrated. Clinically, air-conduction thresholds inside and outside the sound booth, corresponded within 5 dB or less > 90% of instances (mean absolute difference 3.3 ± 3.2 SD). Bone conduction thresholds corresponded within 5 dB or less in 80% of comparisons between test environments, with a mean absolute difference of 4.6 dB (3.7 SD). Threshold differences were not statistically significant. Mean absolute test-retest differences outside the sound booth was similar to those in the booth. Diagnostic pure-tone audiometry outside a sound booth, using automated testing, improved passive attenuation, and real-time environmental noise monitoring demonstrated reliable hearing assessments.

  6. On-chip Micro- and Nanofluidic Electrokinetic Injection and Separation for PEGylation Analysis

    NASA Astrophysics Data System (ADS)

    Shelton, Elijah; Baum, Mary; Morse, Dan; Pennathur, Sumita; Pennathur Nanofluidics Laboratory Collaboration; Morse Laboratory Collaboration

    2012-11-01

    We present an experimental study of micro- and nanofluidic electrokinetic injection and separation in borosilcate channels as a method for characterizing size and zeta potential of biomolecules-specifically polyethlylene glycol (PEG), keyhole limpet hemocyanine (KLH), and pegylated KLH. While pegylation (the conjugation of proteins with PEG) is an established technique for enhancing a protein's therapeutic properties, reliable characterization of these conjugations by traditional analysis techniques (i.e. gel-electrophoresis, zetasizer) remains a challenge. Using a three-step electrokinetic sequence (load, gate, and inject), FITC labeled species and a fluorescein tracer dye are injected into a channel where they separate according to differences in electrophoretic mobility. We find the average absolute mobility of pegylated subunit KLH in 1 micron channels to be 56% that of unpegylated subunit KLH. In a 250 nm channel, we measure a 33% shift in the average absolute mobility of PEG dendrimers as compared to measurements in a 1 micron channel. These results begin to demonstrate how a micro- and nanofluidic-based approach might address the demand for effective and accessible nanoparticle characterization platforms. Supported by the Institute for Collaborative Biotechnologies.

  7. Investigating maternal risk factors as potential targets of intervention to reduce socioeconomic inequality in small for gestational age: a population-based study.

    PubMed

    Hayward, Irene; Malcoe, Lorraine Halinka; Cleathero, Lesley A; Janssen, Patricia A; Lanphear, Bruce P; Hayes, Michael V; Mattman, Andre; Pampalon, Robert; Venners, Scott A

    2012-06-13

    The major aim of this study was to investigate whether maternal risk factors associated with socioeconomic status and small for gestational age (SGA) might be viable targets of interventions to reduce differential risk of SGA by socioeconomic status (socioeconomic SGA inequality) in the metropolitan area of Vancouver, Canada. This study included 59,039 live, singleton births in the Vancouver Census Metropolitan Area (Vancouver) from January 1, 2006 to September 17, 2009. To identify an indicator of socioeconomic SGA inequality, we used hierarchical logistic regression to model SGA by area-level variables from the Canadian census. We then modelled SGA by area-level average income plus established maternal risk factors for SGA and calculated population attributable SGA risk percentages (PAR%) for each variable. Associations of maternal risk factors for SGA with average income were investigated to identify those that might contribute to SGA inequality. Finally, we estimated crude reductions in the percentage and absolute differences in SGA risks between highest and lowest average income quintiles that would result if interventions on maternal risk factors successfully equalized them across income levels or eliminated them altogether. Average income produced the most linear and statistically significant indicator of socioeconomic SGA inequality with 8.9% prevalence of SGA in the lowest income quintile compared to 5.6% in the highest. The adjusted PAR% of SGA for variables were: bottom four quintiles of height (51%), first birth (32%), bottom four quintiles of average income (14%), oligohydramnios (7%), underweight or hypertension, (6% each), smoking (3%) and placental disorder (1%). Shorter height, underweight and smoking during pregnancy had higher prevalence in lower income groups. Crude models assuming equalization of risk factors across income levels or elimination altogether indicated little potential change in relative socioeconomic SGA inequality and reduction in absolute SGA inequality for shorter height only. Our findings regarding maternal height may indicate trans-generational aetiology for socioeconomic SGA inequalities and/or that adult height influences social mobility. Conditions affecting foetal and childhood growth might be viable targets to reduce absolute socioeconomic SGA inequality in future generations, but more research is needed to determine whether such an approach is appropriate.

  8. Results of Absolute Cavity Pyrgeometer (ACP), InfraRed Integrating Sphere (IRIS), and Atmospheric Emitted Radiance Interferometer (AERI) Comparisons and CIMO Recommendations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reda, Ibrahim M; Dooraghi, Michael R; Sengupta, Manajit

    Presenting results of five comparisons between ACPs and IRISs and the difference between the longwave irradiance measured by the ACPs and IRISs versus the average irradiance measured by the WISG. The process of CIMO recommendation to establish the world reference for measuring the atmospheric longwave irradiance with traceability to the International System of Units (SI) is also presented.

  9. Comparison of the arithmetic and geometric means in estimating crown diameter and crown cross-sectional area

    Treesearch

    KaDonna Randolph

    2010-01-01

    The use of the geometric and arithmetic means for estimating tree crown diameter and crown cross-sectional area were examined for trees with crown width measurements taken at the widest point of the crown and perpendicular to the widest point of the crown. The average difference between the geometric and arithmetic mean crown diameters was less than 0.2 ft in absolute...

  10. Directly relating gas-phase cluster measurements to solution-phase hydrolysis, the absolute standard hydrogen electrode potential, and the absolute proton solvation energy.

    PubMed

    Donald, William A; Leib, Ryan D; O'Brien, Jeremy T; Williams, Evan R

    2009-06-08

    Solution-phase, half-cell potentials are measured relative to other half-cell potentials, resulting in a thermochemical ladder that is anchored to the standard hydrogen electrode (SHE), which is assigned an arbitrary value of 0 V. A new method for measuring the absolute SHE potential is demonstrated in which gaseous nanodrops containing divalent alkaline-earth or transition-metal ions are reduced by thermally generated electrons. Energies for the reactions 1) M(H(2)O)(24)(2+)(g) + e(-)(g)-->M(H(2)O)(24)(+)(g) and 2) M(H(2)O)(24)(2+)(g) + e(-)(g)-->MOH(H(2)O)(23)(+)(g) + H(g) and the hydrogen atom affinities of MOH(H(2)O)(23)(+)(g) are obtained from the number of water molecules lost through each pathway. From these measurements on clusters containing nine different metal ions and known thermochemical values that include solution hydrolysis energies, an average absolute SHE potential of +4.29 V vs. e(-)(g) (standard deviation of 0.02 V) and a real proton solvation free energy of -265 kcal mol(-1) are obtained. With this method, the absolute SHE potential can be obtained from a one-electron reduction of nanodrops containing divalent ions that are not observed to undergo one-electron reduction in aqueous solution.

  11. Directly Relating Gas-Phase Cluster Measurements to Solution-Phase Hydrolysis, the Absolute Standard Hydrogen Electrode Potential, and the Absolute Proton Solvation Energy

    PubMed Central

    Donald, William A.; Leib, Ryan D.; O’Brien, Jeremy T.; Williams, Evan R.

    2009-01-01

    Solution-phase, half-cell potentials are measured relative to other half-cell potentials, resulting in a thermochemical ladder that is anchored to the standard hydrogen electrode (SHE), which is assigned an arbitrary value of 0 V. A new method for measuring the absolute SHE potential is demonstrated in which gaseous nanodrops containing divalent alkaline-earth or transition-metal ions are reduced by thermally generated electrons. Energies for the reactions 1) M-(H2O)242+(g)+e−(g)→M(H2O)24+(g) and 2) M(H2O)242+(g)+e−(g)→MOH(H2O)23+(g)+H(g) and the hydrogen atom affinities of MOH(H2O)23+(g) are obtained from the number of water molecules lost through each pathway. From these measurements on clusters containing nine different metal ions and known thermochemical values that include solution hydrolysis energies, an average absolute SHE potential of +4.29 V vs. e−(g) (standard deviation of 0.02 V) and a real proton solvation free energy of −265 kcal mol−1 are obtained. With this method, the absolute SHE potential can be obtained from a one-electron reduction of nanodrops containing divalent ions that are not observed to undergo one-electron reduction in aqueous solution. PMID:19440999

  12. A quantitative evaluation of the three dimensional reconstruction of patients' coronary arteries.

    PubMed

    Klein, J L; Hoff, J G; Peifer, J W; Folks, R; Cooke, C D; King, S B; Garcia, E V

    1998-04-01

    Through extensive training and experience angiographers learn to mentally reconstruct the three dimensional (3D) relationships of the coronary arterial branches. Graphic computer technology can assist angiographers to more quickly visualize the coronary 3D structure from limited initial views and then help to determine additional helpful views by predicting subsequent angiograms before they are obtained. A new computer method for facilitating 3D reconstruction and visualization of human coronary arteries was evaluated by reconstructing biplane left coronary angiograms from 30 patients. The accuracy of the reconstruction was assessed in two ways: 1) by comparing the vessel's centerlines of the actual angiograms with the centerlines of a 2D projection of the 3D model projected into the exact angle of the actual angiogram; and 2) by comparing two 3D models generated by different simultaneous pairs on angiograms. The inter- and intraobserver variability of reconstruction were evaluated by mathematically comparing the 3D model centerlines of repeated reconstructions. The average absolute corrected displacement of 14,662 vessel centerline points in 2D from 30 patients was 1.64 +/- 2.26 mm. The average corrected absolute displacement of 3D models generated from different biplane pairs was 7.08 +/- 3.21 mm. The intraobserver variability of absolute 3D corrected displacement was 5.22 +/- 3.39 mm. The interobserver variability was 6.6 +/- 3.1 mm. The centerline analyses show that the reconstruction algorithm is mathematically accurate and reproducible. The figures presented in this report put these measurement errors into clinical perspective showing that they yield an accurate representation of the clinically relevant information seen on the actual angiograms. These data show that this technique can be clinically useful by accurately displaying in three dimensions the complex relationships of the branches of the coronary arterial tree.

  13. Current Reversals of an Underdamped Brownian Particle in an Asymmetric Deformable Potential

    NASA Astrophysics Data System (ADS)

    Cai, Chun-Chun; Liu, Jian-Li; Chen, Hao; Li, Feng-Guo

    2018-03-01

    Transport of an underdamped Brownian particle in a one-dimensional asymmetric deformable potential is investigated in the presence of both an ac force and a static force, respectively. From numerical simulations, we obtain the current average velocity. The current reversals and the absolute negative mobility are presented. The increasing of the deformation of the potential can cause the absolute negative mobility to be suppressed and even disappear. When the static force is small, the increase of the potential deformation suppresses the absolute negative mobility. When the force is large, the absolute negative mobility disappears. In particular, when the potential deformation is equal to 0.015, the two current reversals present with the increasing of the force. Remarkably, when the potential deformation is small, there are three current reversals with the increasing of the friction coefficient and the average velocity presents a oscillation behavior. Supported in part by the National Natural Science Foundation of China under Grant Nos. 11575064 and 11175067, and the Natural Science Foundation of Guangdong Province under Grant No. 2016A030313433

  14. First metatarsal length change after basilar closing wedge osteotomy for hallux valgus.

    PubMed

    Day, Thomas; Charlton, Timothy P; Thordarson, David B

    2011-05-01

    Hallux valgus deformities with large intermetatarsal angles require a more proximal metatarsal procedure to adequately correct the deformity. Due to the relative ease of a closing wedge osteotomy, this technique was adopted but with concern over first metatarsal shortening. In this study, we primarily evaluated angular correction and first metatarsal shortening. We evaluated 70 feet in 57 patients (average age, 54 years) with 52 female and five male. The average followup was 14 (range, 6 to 45) months. The charts were reviewed for the presence of metatarsalgia. Digital radiographic measurements were made for pre- and postoperative hallux valgus and intermetatarsal angles, dorsiflexion angle of the first metatarsal, and absolute and relative shortening of the first metatarsal. The average hallux valgus angle improved from 31 to 11 degrees (p < 0.0001) and intermetatarsal angle from 13.2 to 4.4 angles (p < 0.0001). The absolute shortening of the first metatarsal was 2.2 mm and relative shortening was 0.6 mm. There was 1.3 degrees of dorsiflexion on average. Excellent correction of the deformity with minimal dorsiflexion or new complaints of metatarsalgia was found with this technique. The new method of assessing the relative shortening found to be less than the absolute shortening, which we feel more accurately reflects the functional length of the first metatarsal.

  15. Commissioning of a 3D image‐based treatment planning system for high‐dose‐rate brachytherapy of cervical cancer

    PubMed Central

    Kim, Yongbok; Modrick, Joseph M.; Pennington, Edward C.

    2016-01-01

    The objective of this work is to present commissioning procedures to clinically implement a three‐dimensional (3D), image‐based, treatment‐planning system (TPS) for high‐dose‐rate (HDR) brachytherapy (BT) for gynecological (GYN) cancer. The physical dimensions of the GYN applicators and their values in the virtual applicator library were varied by 0.4 mm of their nominal values. Reconstruction uncertainties of the titanium tandem and ovoids (T&O) were less than 0.4 mm on CT phantom studies and on average between 0.8‐1.0 mm on MRI when compared with X‐rays. In‐house software, HDRCalculator, was developed to check HDR plan parameters such as independently verifying active tandem or cylinder probe length and ovoid or cylinder size, source calibration and treatment date, and differences between average Point A dose and prescription dose. Dose‐volume histograms were validated using another independent TPS. Comprehensive procedures to commission volume optimization algorithms and process in 3D image‐based planning were presented. For the difference between line and volume optimizations, the average absolute differences as a percentage were 1.4% for total reference air KERMA (TRAK) and 1.1% for Point A dose. Volume optimization consistency tests between versions resulted in average absolute differences in 0.2% for TRAK and 0.9 s (0.2%) for total treatment time. The data revealed that the optimizer should run for at least 1 min in order to avoid more than 0.6% dwell time changes. For clinical GYN T&O cases, three different volume optimization techniques (graphical optimization, pure inverse planning, and hybrid inverse optimization) were investigated by comparing them against a conventional Point A technique. End‐to‐end testing was performed using a T&O phantom to ensure no errors or inconsistencies occurred from imaging through to planning and delivery. The proposed commissioning procedures provide a clinically safe implementation technique for 3D image‐based TPS for HDR BT for GYN cancer. PACS number(s): 87.55.D‐ PMID:27074463

  16. Earthquakes Magnitude Predication Using Artificial Neural Network in Northern Red Sea Area

    NASA Astrophysics Data System (ADS)

    Alarifi, A. S.; Alarifi, N. S.

    2009-12-01

    Earthquakes are natural hazards that do not happen very often, however they may cause huge losses in life and property. Early preparation for these hazards is a key factor to reduce their damage and consequence. Since early ages, people tried to predicate earthquakes using simple observations such as strange or a typical animal behavior. In this paper, we study data collected from existing earthquake catalogue to give better forecasting for future earthquakes. The 16000 events cover a time span of 1970 to 2009, the magnitude range from greater than 0 to less than 7.2 while the depth range from greater than 0 to less than 100km. We propose a new artificial intelligent predication system based on artificial neural network, which can be used to predicate the magnitude of future earthquakes in northern Red Sea area including the Sinai Peninsula, the Gulf of Aqaba, and the Gulf of Suez. We propose a feed forward new neural network model with multi-hidden layers to predicate earthquakes occurrences and magnitudes in northern Red Sea area. Although there are similar model that have been published before in different areas, to our best knowledge this is the first neural network model to predicate earthquake in northern Red Sea area. Furthermore, we present other forecasting methods such as moving average over different interval, normally distributed random predicator, and uniformly distributed random predicator. In addition, we present different statistical methods and data fitting such as linear, quadratic, and cubic regression. We present a details performance analyses of the proposed methods for different evaluation metrics. The results show that neural network model provides higher forecast accuracy than other proposed methods. The results show that neural network achieves an average absolute error of 2.6% while an average absolute error of 3.8%, 7.3% and 6.17% for moving average, linear regression and cubic regression, respectively. In this work, we show an analysis of earthquakes data in northern Red Sea area for different statistics parameters such as correlation, mean, standard deviation, and other. This analysis is to provide a deep understand of the Seismicity of the area, and existing patterns.

  17. A Case Study to Improve Emergency Room Patient Flow at Womack Army Medical Center

    DTIC Science & Technology

    2009-06-01

    use just the previous month, moving average 2-month period ( MA2 ) uses the average from the previous two months, moving average 3-month period (MA3...ED prior to discharge by provider) MA2 /MA3/MA4 - moving averages of 2-4 months in length MAD - mean absolute deviation (measure of accuracy for

  18. Income and Well-Being: Relative Income and Absolute Income Weaken Negative Emotion, but Only Relative Income Improves Positive Emotion.

    PubMed

    Yu, Zonghuo; Chen, Li

    2016-01-01

    Whether relative income or absolute income could affect subjective well-being has been a bone of contention for years. Life satisfaction and the relative frequency of positive and negative emotions are parts of subjective well-being. According to the prospect theory, hedonic adaptation helps to explain why positive emotion is often so hard to be maintained, and negative emotion wouldn't be easy to be eliminated. So we expect the relationship between income and positive emotion is different from that between income and negative emotion. Given that regional reference is the main comparison mechanism, effects of regional average income on regional average subjective well-being should be potentially zero if only relative income matters. Using multilevel analysis, we tested the hypotheses with a dataset of 30,144 individuals from 162 counties in China. The results suggested that household income at the individual level is associated with life satisfaction, happiness and negative emotions. On the contrary, at a county level, household income is only associated with negative emotion. In other words, happiness and life satisfaction was only associated with relative income, but negative emotion was associated with relative income and absolute income. Without social comparison, income doesn't improve happiness, but it could weaken negative emotion. Therefore, it is possible for economic growth to weaken negative emotion without improving happiness. These findings also contribute to the current debate about the "Esterling paradox."

  19. Sampling for area estimation: A comparison of full-frame sampling with the sample segment approach

    NASA Technical Reports Server (NTRS)

    Hixson, M.; Bauer, M. E.; Davis, B. J. (Principal Investigator)

    1979-01-01

    The author has identified the following significant results. Full-frame classifications of wheat and non-wheat for eighty counties in Kansas were repetitively sampled to simulate alternative sampling plans. Evaluation of four sampling schemes involving different numbers of samples and different size sampling units shows that the precision of the wheat estimates increased as the segment size decreased and the number of segments was increased. Although the average bias associated with the various sampling schemes was not significantly different, the maximum absolute bias was directly related to sampling size unit.

  20. Defining the Molecular Actions of Dietary Fatty Acids in Breast Cancer: Selective Modulation of Peroxisome Proliferator-Activated Receptor Gamma

    DTIC Science & Technology

    2006-12-01

    hypothesis testing (ANOVA) using icrosoft Excel v10.0 atα= 0.05 significance threshold. Fol- owing ANOVA, Fisher’s least significant difference, LSD , air...critical value (α= 0.05) ound in the t distribution. If the average absolute difference etween any two groups was greater than the LSD critical alue...cIntyre, T.M., Pontsler, A.V., Silva, A.R., St Hilaire, A., Xu, Y., Hin- shaw , J.C., Zimmerman, G.A., Hama, K., Aoki, J., Arai, H., Prestwich, G.D

  1. Measuring Time-Averaged Blood Pressure

    NASA Technical Reports Server (NTRS)

    Rothman, Neil S.

    1988-01-01

    Device measures time-averaged component of absolute blood pressure in artery. Includes compliant cuff around artery and external monitoring unit. Ceramic construction in monitoring unit suppresses ebb and flow of pressure-transmitting fluid in sensor chamber. Transducer measures only static component of blood pressure.

  2. Status of use of lunar irradiance for on-orbit calibration

    USGS Publications Warehouse

    Stone, T.C.; Kieffer, H.H.; Anderson, J.M.; ,

    2002-01-01

    Routine observations of the Moon have been acquired by the Robotic Lunar Observatory (ROLO) for over four years. The ROLO instruments measure lunar radiance in 23 VNIR (Moon diameter ???500 pixels) and 9 SWIR (???250 pixels) passbands every month when the Moon is at phase angle less than 90 degrees. These are converted to exoatmospheric values at standard distances using an atmospheric extinction model based on observations of standard stars and a NIST-traceable absolute calibration source. Reduction of the stellar images also provides an independent pathway for absolute calibration. Comparison of stellar-based and lamp-based absolute calibrations of the lunar images currently shows unacceptably large differences. An analytic model of lunar irradiance as a function of phase angle and viewing geometry is derived from the calibrated lunar images. Residuals from models which fit hundreds of observations at each wavelength average less than 2%. Comparison with SeaWiFS observations over three years reveals a small quasi-periodic change in SeaWiFS responsivity that correlates with distance from the Sun for the first two years, then departs from this correlation.

  3. VizieR Online Data Catalog: R absolute magnitudes of Kuiper Belt objects (Peixinho+, 2012)

    NASA Astrophysics Data System (ADS)

    Peixinho, N.; Delsanti, A.; Guilbert-Lepoutre, A.; Gafeira, R.; Lacerda, P.

    2012-06-01

    Compilation of absolute magnitude HRα, B-R color spectral features used in this work. For each object, we computed the average color index from the different papers presenting data obtained simultaneously in B and R bands (e.g. contiguous observations within a same night). When individual R apparent magnitude and date were available, we computed the HRα=R-5log(r Delta), where R is the R-band magnitude, r and Delta are the helio- and geocentric distances at the time of observation in AU, respectively. When V and V-R colors were available, we derived an R and then HRα value. We did not correct for the phase-angle α effect. This table includes also spectral information on the presence of water ice, methanol, methane, or confirmed featureless spectra, as available in the literature. We highlight only the cases with clear bands in the spectrum, which were reported/confirmed by some other work. The 1st column indicates the object identification number and name or provisional designation; the 2nd column indicates the dynamical class; the 3rd column indicates the average HRα value and 1-σ error bars; the 4th column indicates the average $B-R$ color and 1-σ error bars; the 5th column indicates the most important spectral features detected; and the 6th column points to the bibliographic references used for each object. (3 data files).

  4. Dosimetric study of uniform scanning proton therapy planning for prostate cancer patients with a metal hip prosthesis, and comparison with volumetric‐modulated arc therapy

    PubMed Central

    Cheng, ChihYao; Zheng, Yuanshui; Hsi, Wen; Zeidan, Omar; Schreuder, Niek; Vargas, Carlos; Larson, Gary

    2014-01-01

    The main purposes of this study were to 1) investigate the dosimetric quality of uniform scanning proton therapy planning (USPT) for prostate cancer patients with a metal hip prosthesis, and 2) compare the dosimetric results of USPT with that of volumetric‐modulated arc therapy (VMAT). Proton plans for prostate cancer (four cases) were generated in XiO treatment planning system (TPS). The beam arrangement in each proton plan consisted of three fields (two oblique fields and one lateral or slightly angled field), and the proton beams passing through a metal hip prosthesis was avoided. Dose calculations in proton plans were performed using the pencil beam algorithm. From each proton plan, planning target volume (PTV) coverage value (i.e., relative volume of the PTV receiving the prescription dose of 79.2 CGE) was recorded. The VMAT prostate planning was done using two arcs in the Eclipse TPS utilizing 6 MV X‐rays, and beam entrance through metallic hip prosthesis was avoided. Dose computation in the VMAT plans was done using anisotropic analytical algorithm, and calculated VMAT plans were then normalized such that the PTV coverage in the VMAT plan was the same as in the proton plan of the corresponding case. The dose‐volume histograms of calculated treatment plans were used to evaluate the dosimetric quality of USPT and VMAT. In comparison to the proton plans, on average, the maximum and mean doses to the PTV were higher in the VMAT plans by 1.4% and 0.5%, respectively, whereas the minimum PTV dose was lower in the VMAT plans by 3.4%. The proton plans had lower (or better) average homogeneity index (HI) of 0.03 compared to the one for VMAT (HI = 0.04). The relative rectal volume exposed to radiation was lower in the proton plan, with an average absolute difference ranging from 0.1% to 32.6%. In contrast, using proton planning, the relative bladder volume exposed to radiation was higher at high‐dose region with an average absolute difference ranging from 0.4% to 0.8%, and lower at low‐ and medium‐dose regions with an average absolute difference ranging from 2.7% to 10.1%. The average mean dose to the rectum and bladder was lower in the proton plans by 45.1% and 22.0%, respectively, whereas the mean dose to femoral head was lower in VMAT plans by an average difference of 79.6%. In comparison to the VMAT, the proton planning produced lower equivalent uniform dose (EUD) for the rectum (43.7 CGE vs. 51.4 Gy) and higher EUD for the femoral head (16.7 CGE vs. 9.5 Gy), whereas both the VMAT and proton planning produced comparable EUDs for the prostate tumor (76.2 CGE vs. 76.8 Gy) and bladder (50.3 CGE vs. 51.1 Gy). The results presented in this study show that the combination of lateral and oblique fields in USPT planning could potentially provide dosimetric advantage over the VMAT for prostate cancer involving a metallic hip prosthesis. PACS number: 87.55.D‐, 87.55.ne, 87.55.dk PMID:24892333

  5. An investigation of articulatory setting using real-time magnetic resonance imaging

    PubMed Central

    Ramanarayanan, Vikram; Goldstein, Louis; Byrd, Dani; Narayanan, Shrikanth S.

    2013-01-01

    This paper presents an automatic procedure to analyze articulatory setting in speech production using real-time magnetic resonance imaging of the moving human vocal tract. The procedure extracts frames corresponding to inter-speech pauses, speech-ready intervals and absolute rest intervals from magnetic resonance imaging sequences of read and spontaneous speech elicited from five healthy speakers of American English and uses automatically extracted image features to quantify vocal tract posture during these intervals. Statistical analyses show significant differences between vocal tract postures adopted during inter-speech pauses and those at absolute rest before speech; the latter also exhibits a greater variability in the adopted postures. In addition, the articulatory settings adopted during inter-speech pauses in read and spontaneous speech are distinct. The results suggest that adopted vocal tract postures differ on average during rest positions, ready positions and inter-speech pauses, and might, in that order, involve an increasing degree of active control by the cognitive speech planning mechanism. PMID:23862826

  6. Percolation Network Study on the Gas Apparent Permeability of Rock

    NASA Astrophysics Data System (ADS)

    Wang, Y.; Tang, Y. B.; Li, M.

    2017-12-01

    We modeled the gas single phase transport behaviors of monomodal porous media using percolation networks. Different from the liquid absolute permeability, which is only related to topology and morphology of pore space, the gas permeability depends on pore pressure as well. A published gas flow conductance model, included usual viscous flow, slip flow and Knudsen diffusion in cylinder pipe, was used to simulated gas flow in 3D, simple cubic, body-center cubic and face-center cubic networks with different hydraulic radius, different coordination number, and different pipe radius distributions under different average pore pressure. The simulation results showed that the gas apparent permeability kapp obey the `universal' scaling law (independence of network lattices), kapp (z-zc)β, where exponent β is related to pore radius distribution, z is coordination number and zc=1.5. Following up on Bernabé et al.'s (2010) study of the effects of pore connectivity and pore size heterogeneity on liquid absolute permeability, gas apparent permeability kapp model and a new joint gas-liquid permeability (i.e., kapp/k∞) model, which could explain the Klinkenberg phenomenon, were proposed. We satisfactorily tested the models by comparison with published experimental data on glass beads and other datasets.

  7. Comparative study of four time series methods in forecasting typhoid fever incidence in China.

    PubMed

    Zhang, Xingyu; Liu, Yuanyuan; Yang, Min; Zhang, Tao; Young, Alistair A; Li, Xiaosong

    2013-01-01

    Accurate incidence forecasting of infectious disease is critical for early prevention and for better government strategic planning. In this paper, we present a comprehensive study of different forecasting methods based on the monthly incidence of typhoid fever. The seasonal autoregressive integrated moving average (SARIMA) model and three different models inspired by neural networks, namely, back propagation neural networks (BPNN), radial basis function neural networks (RBFNN), and Elman recurrent neural networks (ERNN) were compared. The differences as well as the advantages and disadvantages, among the SARIMA model and the neural networks were summarized and discussed. The data obtained for 2005 to 2009 and for 2010 from the Chinese Center for Disease Control and Prevention were used as modeling and forecasting samples, respectively. The performances were evaluated based on three metrics: mean absolute error (MAE), mean absolute percentage error (MAPE), and mean square error (MSE). The results showed that RBFNN obtained the smallest MAE, MAPE and MSE in both the modeling and forecasting processes. The performances of the four models ranked in descending order were: RBFNN, ERNN, BPNN and the SARIMA model.

  8. Comparative Study of Four Time Series Methods in Forecasting Typhoid Fever Incidence in China

    PubMed Central

    Zhang, Xingyu; Liu, Yuanyuan; Yang, Min; Zhang, Tao; Young, Alistair A.; Li, Xiaosong

    2013-01-01

    Accurate incidence forecasting of infectious disease is critical for early prevention and for better government strategic planning. In this paper, we present a comprehensive study of different forecasting methods based on the monthly incidence of typhoid fever. The seasonal autoregressive integrated moving average (SARIMA) model and three different models inspired by neural networks, namely, back propagation neural networks (BPNN), radial basis function neural networks (RBFNN), and Elman recurrent neural networks (ERNN) were compared. The differences as well as the advantages and disadvantages, among the SARIMA model and the neural networks were summarized and discussed. The data obtained for 2005 to 2009 and for 2010 from the Chinese Center for Disease Control and Prevention were used as modeling and forecasting samples, respectively. The performances were evaluated based on three metrics: mean absolute error (MAE), mean absolute percentage error (MAPE), and mean square error (MSE). The results showed that RBFNN obtained the smallest MAE, MAPE and MSE in both the modeling and forecasting processes. The performances of the four models ranked in descending order were: RBFNN, ERNN, BPNN and the SARIMA model. PMID:23650546

  9. Absolute extinction and the influence of environment - Dark cloud sight lines toward VCT 10, 30, and Walker 67

    NASA Technical Reports Server (NTRS)

    Cardelli, Jason A.; Clayton, Geoffrey C.

    1991-01-01

    The range of validity of the average absolute extinction law (AAEL) proposed by Cardelli et al. (1988 and 1989) is investigated, combining published visible and NIR data with IUE UV observations for three lines of sight through dense dark cloud environments with high values of total-to-selective extinction. The characteristics of the data sets and the reduction and parameterization methods applied are described in detail, and the results are presented in extensive tables and graphs. Good agreement with the AAEL is demonstrated for wavelengths from 3.4 microns to 250 nm, but significant deviations are found at shorter wavelengths (where previous studies of lines of sight through bright nebulosity found good agreement with the AAEL). These differences are attributed to the effects of coatings on small-bump and FUV grains.

  10. Absolute frequency list of the ν3-band transitions of methane at a relative uncertainty level of 10(-11).

    PubMed

    Okubo, Sho; Nakayama, Hirotaka; Iwakuni, Kana; Inaba, Hajime; Sasada, Hiroyuki

    2011-11-21

    We determine the absolute frequencies of 56 rotation-vibration transitions of the ν(3) band of CH(4) from 88.2 to 90.5 THz with a typical uncertainty of 2 kHz corresponding to a relative uncertainty of 2.2 × 10(-11) over an average time of a few hundred seconds. Saturated absorption lines are observed using a difference-frequency-generation source and a cavity-enhanced absorption cell, and the transition frequencies are measured with a fiber-laser-based optical frequency comb referenced to a rubidium atomic clock linked to the international atomic time. The determined value of the P(7) F(2)((2)) line is consistent with the International Committee for Weights and Measures recommendation within the uncertainty. © 2011 Optical Society of America

  11. New method of extracting information of arterial oxygen saturation based on ∑ | 𝚫 |

    NASA Astrophysics Data System (ADS)

    Dai, Wenting; Lin, Ling; Li, Gang

    2017-04-01

    Noninvasive detection of oxygen saturation with near-infrared spectroscopy has been widely used in clinics. In order to further enhance its detection precision and reliability, this paper proposes a method of time domain absolute difference summation (∑|Δ|) based on a dynamic spectrum. In this method, the ratio of absolute differences between intervals of two differential sampling points at the same moment on logarithm photoplethysmography signals of red and infrared light was obtained in turn, and then they obtained a ratio sequence which was screened with a statistical method. Finally, use the summation of the screened ratio sequence as the oxygen saturation coefficient Q. We collected 120 reference samples of SpO2 and then compared the result of two methods, which are ∑|Δ| and peak-peak. Average root-mean-square errors of the two methods were 3.02% and 6.80%, respectively, in the 20 cases which were selected randomly. In addition, the average variance of Q of the 10 samples, which were obtained by the new method, reduced to 22.77% of that obtained by the peak-peak method. Comparing with the commercial product, the new method makes the results more accurate. Theoretical and experimental analysis indicates that the application of the ∑|Δ| method could enhance the precision and reliability of oxygen saturation detection in real time.

  12. New method of extracting information of arterial oxygen saturation based on ∑|𝚫 |

    NASA Astrophysics Data System (ADS)

    Wenting, Dai; Ling, Lin; Gang, Li

    2017-04-01

    Noninvasive detection of oxygen saturation with near-infrared spectroscopy has been widely used in clinics. In order to further enhance its detection precision and reliability, this paper proposes a method of time domain absolute difference summation (∑|Δ|) based on a dynamic spectrum. In this method, the ratio of absolute differences between intervals of two differential sampling points at the same moment on logarithm photoplethysmography signals of red and infrared light was obtained in turn, and then they obtained a ratio sequence which was screened with a statistical method. Finally, use the summation of the screened ratio sequence as the oxygen saturation coefficient Q. We collected 120 reference samples of SpO2 and then compared the result of two methods, which are ∑|Δ| and peak-peak. Average root-mean-square errors of the two methods were 3.02% and 6.80%, respectively, in the 20 cases which were selected randomly. In addition, the average variance of Q of the 10 samples, which were obtained by the new method, reduced to 22.77% of that obtained by the peak-peak method. Comparing with the commercial product, the new method makes the results more accurate. Theoretical and experimental analysis indicates that the application of the ∑|Δ| method could enhance the precision and reliability of oxygen saturation detection in real time.

  13. Trust transitivity in social networks.

    PubMed

    Richters, Oliver; Peixoto, Tiago P

    2011-04-05

    Non-centralized recommendation-based decision making is a central feature of several social and technological processes, such as market dynamics, peer-to-peer file-sharing and the web of trust of digital certification. We investigate the properties of trust propagation on networks, based on a simple metric of trust transitivity. We investigate analytically the percolation properties of trust transitivity in random networks with arbitrary in/out-degree distributions, and compare with numerical realizations. We find that the existence of a non-zero fraction of absolute trust (i.e. entirely confident trust) is a requirement for the viability of global trust propagation in large systems: The average pair-wise trust is marked by a discontinuous transition at a specific fraction of absolute trust, below which it vanishes. Furthermore, we perform an extensive analysis of the Pretty Good Privacy (PGP) web of trust, in view of the concepts introduced. We compare different scenarios of trust distribution: community- and authority-centered. We find that these scenarios lead to sharply different patterns of trust propagation, due to the segregation of authority hubs and densely-connected communities. While the authority-centered scenario is more efficient, and leads to higher average trust values, it favours weakly-connected "fringe" nodes, which are directly trusted by authorities. The community-centered scheme, on the other hand, favours nodes with intermediate in/out-degrees, in detriment of the authorities and its "fringe" peers.

  14. Trust Transitivity in Social Networks

    PubMed Central

    Richters, Oliver; Peixoto, Tiago P.

    2011-01-01

    Non-centralized recommendation-based decision making is a central feature of several social and technological processes, such as market dynamics, peer-to-peer file-sharing and the web of trust of digital certification. We investigate the properties of trust propagation on networks, based on a simple metric of trust transitivity. We investigate analytically the percolation properties of trust transitivity in random networks with arbitrary in/out-degree distributions, and compare with numerical realizations. We find that the existence of a non-zero fraction of absolute trust (i.e. entirely confident trust) is a requirement for the viability of global trust propagation in large systems: The average pair-wise trust is marked by a discontinuous transition at a specific fraction of absolute trust, below which it vanishes. Furthermore, we perform an extensive analysis of the Pretty Good Privacy (PGP) web of trust, in view of the concepts introduced. We compare different scenarios of trust distribution: community- and authority-centered. We find that these scenarios lead to sharply different patterns of trust propagation, due to the segregation of authority hubs and densely-connected communities. While the authority-centered scenario is more efficient, and leads to higher average trust values, it favours weakly-connected “fringe” nodes, which are directly trusted by authorities. The community-centered scheme, on the other hand, favours nodes with intermediate in/out-degrees, in detriment of the authorities and its “fringe” peers. PMID:21483683

  15. SU-E-T-491: Importance of Energy Dependent Protons Per MU Calibration Factors in IMPT Dose Calculations Using Monte Carlo Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Randeniya, S; Mirkovic, D; Titt, U

    2014-06-01

    Purpose: In intensity modulated proton therapy (IMPT), energy dependent, protons per monitor unit (MU) calibration factors are important parameters that determine absolute dose values from energy deposition data obtained from Monte Carlo (MC) simulations. Purpose of this study was to assess the sensitivity of MC-computed absolute dose distributions to the protons/MU calibration factors in IMPT. Methods: A “verification plan” (i.e., treatment beams applied individually to water phantom) of a head and neck patient plan was calculated using MC technique. The patient plan had three beams; one posterior-anterior (PA); two anterior oblique. Dose prescription was 66 Gy in 30 fractions. Ofmore » the total MUs, 58% was delivered in PA beam, 25% and 17% in other two. Energy deposition data obtained from the MC simulation were converted to Gy using energy dependent protons/MU calibrations factors obtained from two methods. First method is based on experimental measurements and MC simulations. Second is based on hand calculations, based on how many ion pairs were produced per proton in the dose monitor and how many ion pairs is equal to 1 MU (vendor recommended method). Dose distributions obtained from method one was compared with those from method two. Results: Average difference of 8% in protons/MU calibration factors between method one and two converted into 27 % difference in absolute dose values for PA beam; although dose distributions preserved the shape of 3D dose distribution qualitatively, they were different quantitatively. For two oblique beams, significant difference in absolute dose was not observed. Conclusion: Results demonstrate that protons/MU calibration factors can have a significant impact on absolute dose values in IMPT depending on the fraction of MUs delivered. When number of MUs increases the effect due to the calibration factors amplify. In determining protons/MU calibration factors, experimental method should be preferred in MC dose calculations. Research supported by National Cancer Institute grant P01CA021239.« less

  16. Tropical Gravity Wave Momentum Fluxes and Latent Heating Distributions

    NASA Technical Reports Server (NTRS)

    Geller, Marvin A.; Zhou, Tiehan; Love, Peter T.

    2015-01-01

    Recent satellite determinations of global distributions of absolute gravity wave (GW) momentum fluxes in the lower stratosphere show maxima over the summer subtropical continents and little evidence of GW momentum fluxes associated with the intertropical convergence zone (ITCZ). This seems to be at odds with parameterizations forGWmomentum fluxes, where the source is a function of latent heating rates, which are largest in the region of the ITCZ in terms of monthly averages. The authors have examined global distributions of atmospheric latent heating, cloud-top-pressure altitudes, and lower-stratosphere absolute GW momentum fluxes and have found that monthly averages of the lower-stratosphere GW momentum fluxes more closely resemble the monthly mean cloud-top altitudes rather than the monthly mean rates of latent heating. These regions of highest cloud-top altitudes occur when rates of latent heating are largest on the time scale of cloud growth. This, plus previously published studies, suggests that convective sources for stratospheric GW momentum fluxes, being a function of the rate of latent heating, will require either a climate model to correctly model this rate of latent heating or some ad hoc adjustments to account for shortcomings in a climate model's land-sea differences in convective latent heating.

  17. Radar prediction of absolute rain fade distributions for earth-satellite paths and general methods for extrapolation of fade statistics to other locations

    NASA Technical Reports Server (NTRS)

    Goldhirsh, J.

    1982-01-01

    The first absolute rain fade distribution method described establishes absolute fade statistics at a given site by means of a sampled radar data base. The second method extrapolates absolute fade statistics from one location to another, given simultaneously measured fade and rain rate statistics at the former. Both methods employ similar conditional fade statistic concepts and long term rain rate distributions. Probability deviations in the 2-19% range, with an 11% average, were obtained upon comparison of measured and predicted levels at given attenuations. The extrapolation of fade distributions to other locations at 28 GHz showed very good agreement with measured data at three sites located in the continental temperate region.

  18. Astrometry With the Hubble Space Telescope: Trigonometric Parallaxes of Planetary Nebula Nuclei NGC 6853, NGC 7293, ABELL 31, and DeHt 5

    NASA Technical Reports Server (NTRS)

    Benedict, G. F.; McArthur, Barbara E.; Napiwotzki, Ralf; Harrison, Thomas E.; Harris, Hugh C.; Nelan, Edmund; Bond, Howard E; Patterson, Richard J.; Ciardullo, Robin

    2009-01-01

    We present absolute parallaxes and relative proper motions for the central stars of the planetary nebulae NGC 6853 (The Dumbbell), NGC 7293 (The Helix), Abell 31, and DeHt 5. This paper details our reduction and analysis using DeHt 5 as an example. We obtain these planetary nebula nuclei (PNNi) parallaxes with astrometric data from Fine Guidance Sensors FGS 1r and FGS 3, white-light interferometers on the Hubble Space Telescope. Proper motions, spectral classifications and VJHKT2M and DDO51 photometry of the stars comprising the astrometric reference frames provide spectrophotometric estimates of reference star absolute parallaxes. Introducing these into our model as observations with error, we determine absolute parallaxes for each PNN. Weighted averaging with previous independent parallax measurements yields an average parallax precision, sigma (sub pi)/ pi = 5%. Derived distances are: d(sub NGC6853) = 405(exp +28 sub -25) pc, d(sub NGC7293) = 216(exp +14 sub -12) pc, d(sub Abell31) = 621(exp +91 sub -70) pc, and d(sub DeHt5) = 345(exp +19 sub -17) pc. These PNNi distances are all smaller than previously derived from spectroscopic analyses of the central stars. To obtain absolute magnitudes from these distances requires estimates of interstellar extinction. We average extinction measurements culled from the literature, from reddening based on PNNi intrinsic colors derived from model SEDs, and an assumption that each PNN experiences the same rate of extinction as a function of distance as do the reference stars nearest (in angular separation) to each central star. We also apply Lutz-Kelker bias corrections. The absolute magnitudes and effective temperatures permit estimates of PNNi radii through both the Stefan-Boltzmann relation and Eddington fluxes. Comparing absolute magnitudes with post-AGB models provides mass estimates. Masses cluster around 0.57 solar Mass, close to the peak of the white dwarf mass distribution. Adding a few more PNNi with well-determined distances and masses, we compare all the PNNi with cooler white dwarfs of similar mass, and confirm, as expected, that PNNi have larger radii than white dwarfs that have reached their final cooling tracks.

  19. Reducing the standard deviation in multiple-assay experiments where the variation matters but the absolute value does not.

    PubMed

    Echenique-Robba, Pablo; Nelo-Bazán, María Alejandra; Carrodeguas, José A

    2013-01-01

    When the value of a quantity x for a number of systems (cells, molecules, people, chunks of metal, DNA vectors, so on) is measured and the aim is to replicate the whole set again for different trials or assays, despite the efforts for a near-equal design, scientists might often obtain quite different measurements. As a consequence, some systems' averages present standard deviations that are too large to render statistically significant results. This work presents a novel correction method of a very low mathematical and numerical complexity that can reduce the standard deviation of such results and increase their statistical significance. Two conditions are to be met: the inter-system variations of x matter while its absolute value does not, and a similar tendency in the values of x must be present in the different assays (or in other words, the results corresponding to different assays must present a high linear correlation). We demonstrate the improvements this method offers with a cell biology experiment, but it can definitely be applied to any problem that conforms to the described structure and requirements and in any quantitative scientific field that deals with data subject to uncertainty.

  20. Individual variation and repeatability of basal metabolism in the bank vole, Clethrionomys glareolus.

    PubMed Central

    Labocha, Marta K.; Sadowska, Edyta T.; Baliga, Katarzyna; Semer, Aleksandra K.; Koteja, Paweł

    2004-01-01

    Basal metabolic rate (BMR) is a fundamental energetic trait and has been measured in hundreds of birds and mammals. Nevertheless, little is known about the consistency of the population-average BMR or its repeatability at the level of individual variation. Here, we report that average mass-independent BMR did not differ between two generations of bank voles or between two trials separated by one month. Individual differences in BMR were highly repeatable across the one month interval: the coefficient of intraclass correlation was 0.70 for absolute log-transformed values and 0.56 for mass-independent values. Thus, BMR can be a meaningful measure of an individual physiological characteristic and can be used to test hypotheses concerning relationships between BMR and other traits. On the other hand, mass-independent BMR did not differ significantly across families, and the coefficient of intraclass correlation for full sibs did not differ from zero, which suggests that heritability of BMR in voles is not high. PMID:15101695

  1. A multicentre audit of HDR/PDR brachytherapy absolute dosimetry in association with the INTERLACE trial (NCT015662405).

    PubMed

    Díez, P; Aird, E G A; Sander, T; Gouldstone, C A; Sharpe, P H G; Lee, C D; Lowe, G; Thomas, R A S; Simnor, T; Bownes, P; Bidmead, M; Gandon, L; Eaton, D; Palmer, A L

    2017-11-09

    A UK multicentre audit to evaluate HDR and PDR brachytherapy has been performed using alanine absolute dosimetry. This is the first national UK audit performing an absolute dose measurement at a clinically relevant distance (20 mm) from the source. It was performed in both INTERLACE (a phase III multicentre trial in cervical cancer) and non-INTERLACE brachytherapy centres treating gynaecological tumours. Forty-seven UK centres (including the National Physical Laboratory) were visited. A simulated line source was generated within each centre's treatment planning system and dwell times calculated to deliver 10 Gy at 20 mm from the midpoint of the central dwell (representative of Point A of the Manchester system). The line source was delivered in a water-equivalent plastic phantom (Barts Solid Water) encased in blocks of PMMA (polymethyl methacrylate) and charge measured with an ion chamber at 3 positions (120° apart, 20 mm from the source). Absorbed dose was then measured with alanine at the same positions and averaged to reduce source positional uncertainties. Charge was also measured at 50 mm from the source (representative of Point B of the Manchester system). Source types included 46 HDR and PDR 192 Ir sources, (7 Flexisource, 24 mHDR-v2, 12 GammaMed HDR Plus, 2 GammaMed PDR Plus, 1 VS2000) and 1 HDR 60 Co source, (Co0.A86). Alanine measurements when compared to the centres' calculated dose showed a mean difference (±SD) of  +1.1% (±1.4%) at 20 mm. Differences were also observed between source types and dose calculation algorithm. Ion chamber measurements demonstrated significant discrepancies between the three holes mainly due to positional variation of the source within the catheter (0.4%-4.9% maximum difference between two holes). This comprehensive audit of absolute dose to water from a simulated line source showed all centres could deliver the prescribed dose to within 5% maximum difference between measurement and calculation.

  2. Ninety-day toxicity evaluation of 1,3,5-trinitrobenzene (Tnb) in Peromyscus leucopus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reddy, T.V.; Torsella, J.; Daniel, F.B.

    1995-12-31

    The subchronic toxicity of TNB in P. leucopus was evaluated by feeding Certified Rodent Diet 5002 supplemented with TNB (0, 150, 375, and 750 mg of TNB/kg diet), for 90 days. The food and water consumption was not significantly different between dose groups (for either sex). The calculated average daily TNB intake for female and male P. leucopus respectively, was 0, 20, 65, 108 and 0, 23, 67, and 113 mg/kg body weight (BW). There were no differences in the absolute body weights between sexes as well as between dose groups. Similarly, the organ weights (absolute and relative) did notmore » differ significantly between the dose groups (in both sexes) with an exception of male P. leucopus group receiving 750 mg TNB diet. In this group the spleen weights, both absolute and relative (g/100 g bw), were increased significantly. A significant increase in white blood cells and reticulocytes were detected. In addition, histopathological examinations in the aforementioned dose group revealed erythroid cell hyperplasia (spleen) and seminiferous tubular degeneration (testes). Although not significant, an increase in methemoglobin levels with an increased dose was evident. When the TNB concentration in the diet was increased to 1,200 and 1,800 mg/kg (used in the range finding study), the above indicated effects were much more prominent and were seen in both sexes. From this study a NOAEL of 20 mg/day/kg for female and 23 mg/day/kg for male is suggested.« less

  3. Thermal sensing of cryogenic wind tunnel model surfaces Evaluation of silicon diodes

    NASA Technical Reports Server (NTRS)

    Daryabeigi, K.; Ash, R. L.; Dillon-Townes, L. A.

    1986-01-01

    Different sensors and installation techniques for surface temperature measurement of cryogenic wind tunnel models were investigated. Silicon diodes were selected for further consideration because of their good inherent accuracy. Their average absolute temperature deviation in comparison tests with standard platinum resistance thermometers was found to be 0.2 K in the range from 125 to 273 K. Subsurface temperature measurement was selected as the installation technique in order to minimize aerodynamic interference. Temperature distortion caused by an embedded silicon diode was studied numerically.

  4. Thermal sensing of cryogenic wind tunnel model surfaces - Evaluation of silicon diodes

    NASA Technical Reports Server (NTRS)

    Daryabeigi, Kamran; Ash, Robert L.; Dillon-Townes, Lawrence A.

    1986-01-01

    Different sensors and installation techniques for surface temperature measurement of cryogenic wind tunnel models were investigated. Silicon diodes were selected for further consideration because of their good inherent accuracy. Their average absolute temperature deviation in comparison tests with standard platinum resistance thermometers was found to be 0.2 K in the range from 125 to 273 K. Subsurface temperature measurement was selected as the installation technique in order to minimize aerodynamic interference. Temperature distortion caused by an embedded silicon diode was studied numerically.

  5. Development of sustainable precision farming systems for swine: estimating real-time individual amino acid requirements in growing-finishing pigs.

    PubMed

    Hauschild, L; Lovatto, P A; Pomar, J; Pomar, C

    2012-07-01

    The objective of this study was to develop and evaluate a mathematical model used to estimate the daily amino acid requirements of individual growing-finishing pigs. The model includes empirical and mechanistic model components. The empirical component estimates daily feed intake (DFI), BW, and daily gain (DG) based on individual pig information collected in real time. Based on DFI, BW, and DG estimates, the mechanistic component uses classic factorial equations to estimate the optimal concentration of amino acids that must be offered to each pig to meet its requirements. The model was evaluated with data from a study that investigated the effect of feeding pigs with a 3-phase or daily multiphase system. The DFI and BW values measured in this study were compared with those estimated by the empirical component of the model. The coherence of the values estimated by the mechanistic component was evaluated by analyzing if it followed a normal pattern of requirements. Lastly, the proposed model was evaluated by comparing its estimates with those generated by the existing growth model (InraPorc). The precision of the proposed model and InraPorc in estimating DFI and BW was evaluated through the mean absolute error. The empirical component results indicated that the DFI and BW trajectories of individual pigs fed ad libitum could be predicted 1 d (DFI) or 7 d (BW) ahead with the average mean absolute error of 12.45 and 1.85%, respectively. The average mean absolute error obtained with the InraPorc for the average individual of the population was 14.72% for DFI and 5.38% for BW. Major differences were observed when estimates from InraPorc were compared with individual observations. The proposed model, however, was effective in tracking the change in DFI and BW for each individual pig. The mechanistic model component estimated the optimal standardized ileal digestible Lys to NE ratio with reasonable between animal (average CV = 7%) and overtime (average CV = 14%) variation. Thus, the amino acid requirements estimated by model are animal- and time-dependent and follow, in real time, the individual DFI and BW growth patterns. The proposed model can follow the average feed intake and feed weight trajectory of each individual pig in real time with good accuracy. Based on these trajectories and using classical factorial equations, the model makes it possible to estimate dynamically the AA requirements of each animal, taking into account the intake and growth changes of the animal.

  6. Interset stretching does not influence the kinematic profile of consecutive bench-press sets.

    PubMed

    García-López, David; Izquierdo, Mikel; Rodríguez, Sergio; González-Calvo, Gustavo; Sainz, Nuria; Abadía, Olaia; Herrero, Azael J

    2010-05-01

    This study was undertaken to examine the role of interset stretching on the time course of acceleration portion AP and mean velocity profile during the concentric phase of 2 bench-press sets with a submaximal load (60% of the 1 repetition maximum). Twenty-five college students carried out, in 3 different days, 2 consecutive bench-press sets leading to failure, performing between sets static stretching, ballistic stretching, or no stretching. Acceleration portion and lifting velocity patterns of the concentric phase were not altered during the second set, regardless of the stretching treatment performed. However, when velocity was expressed in absolute terms, static stretching reduced significantly (p <0.05) the average lifting velocity during the second set compared to the first one. Therefore, if maintenance of a high absolute velocity over consecutive sets is important for training-related adaptations, static stretching should be avoided or replaced by ballistic stretching.

  7. Interobserver reproducibility of The Paris System for Reporting Urinary Cytology.

    PubMed

    Long, Theresa; Layfield, Lester J; Esebua, Magda; Frazier, Shellaine R; Giorgadze, D Tamar; Schmidt, Robert L

    2017-01-01

    The Paris System for Reporting Urinary Cytology represents a significant improvement in classification of urinary specimens. The system acknowledges the difficulty in cytologically diagnosing low-grade urothelial carcinomas and has developed categories to deal with this issue. The system uses six categories: unsatisfactory, negative for high-grade urothelial carcinoma (NHGUC), atypical urothelial cells, suspicious for high-grade urothelial carcinoma, high-grade urothelial carcinoma, other malignancies and a seventh subcategory (low-grade urothelial neoplasm). Three hundred and fifty-seven urine specimens were independently reviewed by four cytopathologists unaware of the previous diagnoses. Each cytopathologist rendered a diagnosis according to the Paris System categories. Agreement was assessed using absolute agreement and weighted chance-corrected agreement (kappa). Disagreements were classified as low impact and high impact based on the potential impact of a misclassification on clinical management. The average absolute agreement was 65% with an average expected agreement of 44%. The average chance-corrected agreement (kappa) was 0.32. Nine hundred and ninety-nine of 1902 comparisons between rater pairs were in agreement, but 12% of comparisons differed by two or more categories for the category NHGUC. Approximately 15% of the disagreements were classified as high clinical impact. Our findings indicated that the scheme recommended by the Paris System shows adequate precision for the category NHGUC, but the other categories demonstrated unacceptable interobserver variability. This low level of diagnostic precision may negatively impact the applicability of the Paris System for widespread clinical application.

  8. Absolute dual-comb spectroscopy at 1.55 μm by free-running Er:fiber lasers

    NASA Astrophysics Data System (ADS)

    Cassinerio, Marco; Gambetta, Alessio; Coluccelli, Nicola; Laporta, Paolo; Galzerano, Gianluca

    2014-06-01

    We report on a compact scheme for absolute referencing and coherent averaging for dual-comb based spectrometers, exploiting a single continuous-wave (CW) laser in a transfer oscillator configuration. The same CW laser is used for both absolute calibration of the optical frequency axis and the generation of a correction signal which is used for a real-time jitter compensation in a fully electrical feed-forward scheme. The technique is applied to a near-infrared spectrometer based on a pair of free-running mode-locked Er:fiber lasers, allowing to perform real-time absolute-frequency measurements over an optical bandwidth of more than 25 nm, with coherent interferogram averaging over 1-s acquisition time, leading to a signal-to-noise ratio improvement of 29 dB over the 50 μs single shot acquisition. Using 10-cm single pass cell, a value of 1.9 × 10-4 cm-1 Hz-0.5 noise-equivalent-absorption over 1 s integration time is obtained, which can be further scaled down with a multi-pass or resonant cavity. The adoption of a single CW laser, together with the absence of optical locks, and the full-fiber design makes this spectrometer a robust and compact system to be employed in gas-sensing applications.

  9. Impact of the Absolute Difference in Diastolic Blood Pressure Between Arms in Patients With Coronary Artery Disease

    PubMed Central

    Hitaka, Yuka; Miura, Shin-ichiro; Koyoshi, Rie; Shiga, Yuhei; Miyase, Yuiko; Norimatsu, Kenji; Nakamura, Ayumi; Adachi, Sen; Kuwano, Takashi; Sugihara, Makoto; Ike, Amane; Nishikawa, Hiroaki; Saku, Keijiro

    2015-01-01

    Background We investigated the relationship between the severity and presence of coronary artery disease (CAD) and a difference in systolic and diastolic blood pressure (SBP and DBP) between arms or between lower limbs. Methods We enrolled 277 patients who underwent coronary angiography. We calculated the absolute (|right BP (rt. BP) - left BP (lt. BP)|) and relative (rt. BP - lt. BP) differences in SBP or DBP between arms or between lower limbs, and assessed the severity of CAD in terms of the Gensini score. Results The absolute difference in DBP between arms in the CAD group was significantly lower than that in the non-CAD group, whereas the absolute difference in DBP between lower limbs in the CAD group was significantly higher. There were no differences in the absolute or relative difference in SBP between arms or lower limbs between the groups. The absolute difference in DBP between arms decreased as the Gensini score increased. In a logistic regression analysis, the presence of CAD was independently associated with the absolute difference in DBP between arms, in addition to male, family history, dyslipidemia, diabetes mellitus and hypertension. Conclusion The absolute difference in DBP between arms in addition to traditional factors may be a critical risk factor for the presence of CAD. PMID:26491500

  10. Impact of the Absolute Difference in Diastolic Blood Pressure Between Arms in Patients With Coronary Artery Disease.

    PubMed

    Hitaka, Yuka; Miura, Shin-Ichiro; Koyoshi, Rie; Shiga, Yuhei; Miyase, Yuiko; Norimatsu, Kenji; Nakamura, Ayumi; Adachi, Sen; Kuwano, Takashi; Sugihara, Makoto; Ike, Amane; Nishikawa, Hiroaki; Saku, Keijiro

    2015-11-01

    We investigated the relationship between the severity and presence of coronary artery disease (CAD) and a difference in systolic and diastolic blood pressure (SBP and DBP) between arms or between lower limbs. We enrolled 277 patients who underwent coronary angiography. We calculated the absolute (|right BP (rt. BP) - left BP (lt. BP)|) and relative (rt. BP - lt. BP) differences in SBP or DBP between arms or between lower limbs, and assessed the severity of CAD in terms of the Gensini score. The absolute difference in DBP between arms in the CAD group was significantly lower than that in the non-CAD group, whereas the absolute difference in DBP between lower limbs in the CAD group was significantly higher. There were no differences in the absolute or relative difference in SBP between arms or lower limbs between the groups. The absolute difference in DBP between arms decreased as the Gensini score increased. In a logistic regression analysis, the presence of CAD was independently associated with the absolute difference in DBP between arms, in addition to male, family history, dyslipidemia, diabetes mellitus and hypertension. The absolute difference in DBP between arms in addition to traditional factors may be a critical risk factor for the presence of CAD.

  11. Dual-Polarization Observations of Slowly Varying Solar Emissions from a Mobile X-Band Radar

    PubMed Central

    Gabella, Marco; Leuenberger, Andreas

    2017-01-01

    The radio noise that comes from the Sun has been reported in literature as a reference signal to check the quality of dual-polarization weather radar receivers for the S-band and C-band. In most cases, the focus was on relative calibration: horizontal and vertical polarizations were evaluated versus the reference signal mainly in terms of standard deviation of the difference. This means that the investigated radar receivers were able to reproduce the slowly varying component of the microwave signal emitted by the Sun. A novel method, aimed at the absolute calibration of dual-polarization receivers, has recently been presented and applied for the C-band. This method requires the antenna beam axis to be pointed towards the center of the Sun for less than a minute. Standard deviations of the difference as low as 0.1 dB have been found for the Swiss radars. As far as the absolute calibration is concerned, the average differences were of the order of −0.6 dB (after noise subtraction). The method has been implemented on a mobile, X-band radar, and this paper presents the successful results that were obtained during the 2016 field campaign in Payerne (Switzerland). Despite a relatively poor Sun-to-Noise ratio, the “small” (~0.4 dB) amplitude of the slowly varying emission was captured and reproduced; the standard deviation of the difference between the radar and the reference was ~0.2 dB. The absolute calibration of the vertical and horizontal receivers was satisfactory. After the noise subtraction and atmospheric correction a, the mean difference was close to 0 dB. PMID:28531164

  12. Dual-Polarization Observations of Slowly Varying Solar Emissions from a Mobile X-Band Radar.

    PubMed

    Gabella, Marco; Leuenberger, Andreas

    2017-05-22

    The radio noise that comes from the Sun has been reported in literature as a reference signal to check the quality of dual-polarization weather radar receivers for the S-band and C-band. In most cases, the focus was on relative calibration: horizontal and vertical polarizations were evaluated versus the reference signal mainly in terms of standard deviation of the difference. This means that the investigated radar receivers were able to reproduce the slowly varying component of the microwave signal emitted by the Sun. A novel method, aimed at the absolute calibration of dual-polarization receivers, has recently been presented and applied for the C-band. This method requires the antenna beam axis to be pointed towards the center of the Sun for less than a minute. Standard deviations of the difference as low as 0.1 dB have been found for the Swiss radars. As far as the absolute calibration is concerned, the average differences were of the order of -0.6 dB (after noise subtraction). The method has been implemented on a mobile, X-band radar, and this paper presents the successful results that were obtained during the 2016 field campaign in Payerne (Switzerland). Despite a relatively poor Sun-to-Noise ratio, the "small" (~0.4 dB) amplitude of the slowly varying emission was captured and reproduced; the standard deviation of the difference between the radar and the reference was ~0.2 dB. The absolute calibration of the vertical and horizontal receivers was satisfactory. After the noise subtraction and atmospheric correction a, the mean difference was close to 0 dB.

  13. Dosimetric validation for an automatic brain metastases planning software using single-isocenter dynamic conformal arcsDosimetric validation for an automatic brain metastases planning software using single-isocenter dynamic conformal arcs.

    PubMed

    Liu, Haisong; Li, Jun; Pappas, Evangelos; Andrews, David; Evans, James; Werner-Wasik, Maria; Yu, Yan; Dicker, Adam; Shi, Wenyin

    2016-09-08

    An automatic brain-metastases planning (ABMP) software has been installed in our institution. It is dedicated for treating multiple brain metastases with radiosurgery on linear accelerators (linacs) using a single-setup isocenter with noncoplanar dynamic conformal arcs. This study is to validate the calculated absolute dose and dose distribution of ABMP. Three types of measurements were performed to validate the planning software: 1, dual micro ion chambers were used with an acrylic phantom to measure the absolute dose; 2, a 3D cylindrical phantom with dual diode array was used to evaluate 2D dose distribution and point dose for smaller targets; and 3, a 3D pseudo-in vivo patient-specific phantom filled with polymer gels was used to evaluate the accuracy of 3D dose distribution and radia-tion delivery. Micro chamber measurement of two targets (volumes of 1.2 cc and 0.9 cc, respectively) showed that the percentage differences of the absolute dose at both targets were less than 1%. Averaged GI passing rate of five different plans measured with the diode array phantom was above 98%, using criteria of 3% dose difference, 1 mm distance to agreement (DTA), and 10% low-dose threshold. 3D gel phantom measurement results demonstrated a 3D displacement of nine targets of 0.7 ± 0.4 mm (range 0.2 ~ 1.1 mm). The averaged two-dimensional (2D) GI passing rate for several region of interests (ROI) on axial slices that encompass each one of the nine targets was above 98% (5% dose difference, 2 mm DTA, and 10% low-dose threshold). Measured D95, the minimum dose that covers 95% of the target volume, of the nine targets was 0.7% less than the calculated D95. Three different types of dosimetric verification methods were used and proved the dose calculation of the new automatic brain metastases planning (ABMP) software was clinical acceptable. The 3D pseudo-in vivo patient-specific gel phantom test also served as an end-to-end test for validating not only the dose calculation, but the treatment delivery accuracy as well. © 2016 The Authors.

  14. Globular Clusters: Absolute Proper Motions and Galactic Orbits

    NASA Astrophysics Data System (ADS)

    Chemel, A. A.; Glushkova, E. V.; Dambis, A. K.; Rastorguev, A. S.; Yalyalieva, L. N.; Klinichev, A. D.

    2018-04-01

    We cross-match objects from several different astronomical catalogs to determine the absolute proper motions of stars within the 30-arcmin radius fields of 115 Milky-Way globular clusters with the accuracy of 1-2 mas yr-1. The proper motions are based on positional data recovered from the USNO-B1, 2MASS, URAT1, ALLWISE, UCAC5, and Gaia DR1 surveys with up to ten positions spanning an epoch difference of up to about 65 years, and reduced to Gaia DR1 TGAS frame using UCAC5 as the reference catalog. Cluster members are photometrically identified by selecting horizontal- and red-giant branch stars on color-magnitude diagrams, and the mean absolute proper motions of the clusters with a typical formal error of about 0.4 mas yr-1 are computed by averaging the proper motions of selected members. The inferred absolute proper motions of clusters are combined with available radial-velocity data and heliocentric distance estimates to compute the cluster orbits in terms of the Galactic potential models based on Miyamoto and Nagai disk, Hernquist spheroid, and modified isothermal dark-matter halo (axisymmetric model without a bar) and the same model + rotating Ferre's bar (non-axisymmetric). Five distant clusters have higher-than-escape velocities, most likely due to large errors of computed transversal velocities, whereas the computed orbits of all other clusters remain bound to the Galaxy. Unlike previously published results, we find the bar to affect substantially the orbits of most of the clusters, even those at large Galactocentric distances, bringing appreciable chaotization, especially in the portions of the orbits close to the Galactic center, and stretching out the orbits of some of the thick-disk clusters.

  15. Increasing educational inequality in preterm birth in Quebec, Canada, 1981-2006.

    PubMed

    Auger, Nathalie; Roncarolo, Federico; Harper, Sam

    2011-12-01

    Few studies have evaluated the relationship between preterm birth (PTB) and maternal education over time. We sought to determine whether educational inequalities in PTB have increased in Québec, Canada. The authors analysed 2,124,909 singleton live births from 1981 to 2006, and computed the Relative Index of Inequality (RII) and Slope Index of Inequality (SII) with 95% CIs for the relationship between maternal education and extreme, very or moderate PTB (≤27, 28-31, and 32-36 completed weeks of gestation, respectively) for five periods (1981-1985, 1986-1990, 1991-1995, 1996-2000, 2001-2006), adjusting for maternal age, marital status, birthplace, language spoken at home, parity and infant sex. Average rates of extreme and moderate PTB increased over time but decreased for very PTB. A statistically significant increase in the RII over time was present for extreme and moderate PTB. The adjusted RII for extreme PTB increased from 1.58 (95% CI 1.24 to 2.01) in 1981-1985 to 3.11 (95% CI 2.54 to 3.81) in 2001-2006. For moderate PTB, the corresponding RIIs were 1.53 (95% CI 1.44 to 1.61) and 1.91 (95% CI 1.81 to 2.01). Absolute differences in the PTB proportion between the least and most educated mothers increased from 1981 to 2006 for extreme (adjusted SII 0.11% vs 0.28%) and moderate PTB (adjusted SII 1.67% vs 3.11%). Absolute differences in the proportion very PTB did not increase. Relative and absolute educational inequalities in extreme and moderate PTB have increased over time in Québec. Relative increases were largest for extreme PTB, and absolute increases were largest for moderate PTB.

  16. Absolute Quantification of Rifampicin by MALDI Imaging Mass Spectrometry Using Multiple TOF/TOF Events in a Single Laser Shot

    NASA Astrophysics Data System (ADS)

    Prentice, Boone M.; Chumbley, Chad W.; Caprioli, Richard M.

    2017-01-01

    Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) allows for the visualization of molecular distributions within tissue sections. While providing excellent molecular specificity and spatial information, absolute quantification by MALDI IMS remains challenging. Especially in the low molecular weight region of the spectrum, analysis is complicated by matrix interferences and ionization suppression. Though tandem mass spectrometry (MS/MS) can be used to ensure chemical specificity and improve sensitivity by eliminating chemical noise, typical MALDI MS/MS modalities only scan for a single MS/MS event per laser shot. Herein, we describe TOF/TOF instrumentation that enables multiple fragmentation events to be performed in a single laser shot, allowing the intensity of the analyte to be referenced to the intensity of the internal standard in each laser shot while maintaining the benefits of MS/MS. This approach is illustrated by the quantitative analyses of rifampicin (RIF), an antibiotic used to treat tuberculosis, in pooled human plasma using rifapentine (RPT) as an internal standard. The results show greater than 4-fold improvements in relative standard deviation as well as improved coefficients of determination (R2) and accuracy (>93% quality controls, <9% relative errors). This technology is used as an imaging modality to measure absolute RIF concentrations in liver tissue from an animal dosed in vivo. Each microspot in the quantitative image measures the local RIF concentration in the tissue section, providing absolute pixel-to-pixel quantification from different tissue microenvironments. The average concentration determined by IMS is in agreement with the concentration determined by HPLC-MS/MS, showing a percent difference of 10.6%.

  17. The absolute disparity anomaly and the mechanism of relative disparities.

    PubMed

    Chopin, Adrien; Levi, Dennis; Knill, David; Bavelier, Daphne

    2016-06-01

    There has been a long-standing debate about the mechanisms underlying the perception of stereoscopic depth and the computation of the relative disparities that it relies on. Relative disparities between visual objects could be computed in two ways: (a) using the difference in the object's absolute disparities (Hypothesis 1) or (b) using relative disparities based on the differences in the monocular separations between objects (Hypothesis 2). To differentiate between these hypotheses, we measured stereoscopic discrimination thresholds for lines with different absolute and relative disparities. Participants were asked to judge the depth of two lines presented at the same distance from the fixation plane (absolute disparity) or the depth between two lines presented at different distances (relative disparity). We used a single stimulus method involving a unique memory component for both conditions, and no extraneous references were available. We also measured vergence noise using Nonius lines. Stereo thresholds were substantially worse for absolute disparities than for relative disparities, and the difference could not be explained by vergence noise. We attribute this difference to an absence of conscious readout of absolute disparities, termed the absolute disparity anomaly. We further show that the pattern of correlations between vergence noise and absolute and relative disparity acuities can be explained jointly by the existence of the absolute disparity anomaly and by the assumption that relative disparity information is computed from absolute disparities (Hypothesis 1).

  18. The absolute disparity anomaly and the mechanism of relative disparities

    PubMed Central

    Chopin, Adrien; Levi, Dennis; Knill, David; Bavelier, Daphne

    2016-01-01

    There has been a long-standing debate about the mechanisms underlying the perception of stereoscopic depth and the computation of the relative disparities that it relies on. Relative disparities between visual objects could be computed in two ways: (a) using the difference in the object's absolute disparities (Hypothesis 1) or (b) using relative disparities based on the differences in the monocular separations between objects (Hypothesis 2). To differentiate between these hypotheses, we measured stereoscopic discrimination thresholds for lines with different absolute and relative disparities. Participants were asked to judge the depth of two lines presented at the same distance from the fixation plane (absolute disparity) or the depth between two lines presented at different distances (relative disparity). We used a single stimulus method involving a unique memory component for both conditions, and no extraneous references were available. We also measured vergence noise using Nonius lines. Stereo thresholds were substantially worse for absolute disparities than for relative disparities, and the difference could not be explained by vergence noise. We attribute this difference to an absence of conscious readout of absolute disparities, termed the absolute disparity anomaly. We further show that the pattern of correlations between vergence noise and absolute and relative disparity acuities can be explained jointly by the existence of the absolute disparity anomaly and by the assumption that relative disparity information is computed from absolute disparities (Hypothesis 1). PMID:27248566

  19. Statistical Analysis on the Performance of Molecular Mechanics Poisson–Boltzmann Surface Area versus Absolute Binding Free Energy Calculations: Bromodomains as a Case Study

    PubMed Central

    2017-01-01

    Binding free energy calculations that make use of alchemical pathways are becoming increasingly feasible thanks to advances in hardware and algorithms. Although relative binding free energy (RBFE) calculations are starting to find widespread use, absolute binding free energy (ABFE) calculations are still being explored mainly in academic settings due to the high computational requirements and still uncertain predictive value. However, in some drug design scenarios, RBFE calculations are not applicable and ABFE calculations could provide an alternative. Computationally cheaper end-point calculations in implicit solvent, such as molecular mechanics Poisson–Boltzmann surface area (MMPBSA) calculations, could too be used if one is primarily interested in a relative ranking of affinities. Here, we compare MMPBSA calculations to previously performed absolute alchemical free energy calculations in their ability to correlate with experimental binding free energies for three sets of bromodomain–inhibitor pairs. Different MMPBSA approaches have been considered, including a standard single-trajectory protocol, a protocol that includes a binding entropy estimate, and protocols that take into account the ligand hydration shell. Despite the improvements observed with the latter two MMPBSA approaches, ABFE calculations were found to be overall superior in obtaining correlation with experimental affinities for the test cases considered. A difference in weighted average Pearson () and Spearman () correlations of 0.25 and 0.31 was observed when using a standard single-trajectory MMPBSA setup ( = 0.64 and = 0.66 for ABFE; = 0.39 and = 0.35 for MMPBSA). The best performing MMPBSA protocols returned weighted average Pearson and Spearman correlations that were about 0.1 inferior to ABFE calculations: = 0.55 and = 0.56 when including an entropy estimate, and = 0.53 and = 0.55 when including explicit water molecules. Overall, the study suggests that ABFE calculations are indeed the more accurate approach, yet there is also value in MMPBSA calculations considering the lower compute requirements, and if agreement to experimental affinities in absolute terms is not of interest. Moreover, for the specific protein–ligand systems considered in this study, we find that including an explicit ligand hydration shell or a binding entropy estimate in the MMPBSA calculations resulted in significant performance improvements at a negligible computational cost. PMID:28786670

  20. A Robust Interpretation of Teaching Evaluation Ratings

    ERIC Educational Resources Information Center

    Bi, Henry H.

    2018-01-01

    There are no absolute standards regarding what teaching evaluation ratings are satisfactory. It is also problematic to compare teaching evaluation ratings with the average or with a cutoff number to determine whether they are adequate. In this paper, we use average and standard deviation charts (X[overbar]-S charts), which are based on the theory…

  1. Intelligent Ensemble Forecasting System of Stock Market Fluctuations Based on Symetric and Asymetric Wavelet Functions

    NASA Astrophysics Data System (ADS)

    Lahmiri, Salim; Boukadoum, Mounir

    2015-08-01

    We present a new ensemble system for stock market returns prediction where continuous wavelet transform (CWT) is used to analyze return series and backpropagation neural networks (BPNNs) for processing CWT-based coefficients, determining the optimal ensemble weights, and providing final forecasts. Particle swarm optimization (PSO) is used for finding optimal weights and biases for each BPNN. To capture symmetry/asymmetry in the underlying data, three wavelet functions with different shapes are adopted. The proposed ensemble system was tested on three Asian stock markets: The Hang Seng, KOSPI, and Taiwan stock market data. Three statistical metrics were used to evaluate the forecasting accuracy; including, mean of absolute errors (MAE), root mean of squared errors (RMSE), and mean of absolute deviations (MADs). Experimental results showed that our proposed ensemble system outperformed the individual CWT-ANN models each with different wavelet function. In addition, the proposed ensemble system outperformed the conventional autoregressive moving average process. As a result, the proposed ensemble system is suitable to capture symmetry/asymmetry in financial data fluctuations for better prediction accuracy.

  2. Backscatter calibration of high-frequency multibeam echosounder using a reference single-beam system, on natural seafloor

    NASA Astrophysics Data System (ADS)

    Eleftherakis, Dimitrios; Berger, Laurent; Le Bouffant, Naig; Pacault, Anne; Augustin, Jean-Marie; Lurton, Xavier

    2018-06-01

    The calibration of multibeam echosounders for backscatter measurements can be conducted efficiently and accurately using data from surveys over a reference natural area, implying appropriate measurements of the local absolute values of backscatter. Such a shallow area (20-m mean depth) has been defined and qualified in the Bay of Brest (France), and chosen as a reference area for multibeam systems operating at 200 and 300 kHz. The absolute reflectivity over the area was measured using a calibrated single-beam fishery echosounder (Simrad EK60) tilted at incidence angles varying between 0° and 60° with a step of 3°. This reference backscatter level is then compared to the average backscatter values obtained by a multibeam echosounder (here a Kongsberg EM 2040-D) at a close frequency and measured as a function of angle; the difference gives the angular bias applicable to the multibeam system for recorded level calibration. The method is validated by checking the single- and multibeam data obtained on other areas with sediment types different from the reference area.

  3. Geographic patterns of fishes and jellyfish in Puget Sound surface waters

    USGS Publications Warehouse

    Rice, Casimir A.; Duda, Jeffrey J.; Greene, Correigh M.; Karr, James R.

    2012-01-01

    We explored patterns of small pelagic fish assemblages and biomass of gelatinous zooplankton (jellyfish) in surface waters across four oceanographic subbasins of greater Puget Sound. Our study is the first to collect data documenting biomass of small pelagic fishes and jellyfish throughout Puget Sound; sampling was conducted opportunistically as part of a juvenile salmon survey of daytime monthly surface trawls at 52 sites during May–August 2003. Biomass composition differed spatially and temporally, but spatial differences were more distinct. Fish dominated in the two northern basins of Puget Sound, whereas jellyfish dominated in the two southern basins. Absolute and relative abundance of jellyfish, hatchery Chinook salmon Oncorhynchus tshawytscha, and chum salmon O. keta decreased with increasing latitude, whereas the absolute and relative abundance of most fish species and the average fish species richness increased with latitude. The abiotic factors with the strongest relationship to biomass composition were latitude, water clarity, and sampling date. Further study is needed to understand the spatial and temporal heterogeneity in the taxonomic composition we observed in Puget Sound surface waters, especially as they relate to natural and anthropogenic influences.

  4. Sampling for area estimation: A comparison of full-frame sampling with the sample segment approach. [Kansas

    NASA Technical Reports Server (NTRS)

    Hixson, M. M.; Bauer, M. E.; Davis, B. J.

    1979-01-01

    The effect of sampling on the accuracy (precision and bias) of crop area estimates made from classifications of LANDSAT MSS data was investigated. Full-frame classifications of wheat and non-wheat for eighty counties in Kansas were repetitively sampled to simulate alternative sampling plants. Four sampling schemes involving different numbers of samples and different size sampling units were evaluated. The precision of the wheat area estimates increased as the segment size decreased and the number of segments was increased. Although the average bias associated with the various sampling schemes was not significantly different, the maximum absolute bias was directly related to sampling unit size.

  5. Calibration Against the Moon. I: A Disk-Resolved Lunar Model for Absolute Reflectance Calibration

    DTIC Science & Technology

    2010-01-01

    average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and...3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Calibration against the Moon I: A disk- resolved lunar model for absolute reflectance...of the disk- resolved Moon at visible to near infrared wavelengths. It has been developed in order to use the Moon as a calibration reference

  6. Surveying implicit solvent models for estimating small molecule absolute hydration free energies

    PubMed Central

    Knight, Jennifer L.

    2011-01-01

    Implicit solvent models are powerful tools in accounting for the aqueous environment at a fraction of the computational expense of explicit solvent representations. Here, we compare the ability of common implicit solvent models (TC, OBC, OBC2, GBMV, GBMV2, GBSW, GBSW/MS, GBSW/MS2 and FACTS) to reproduce experimental absolute hydration free energies for a series of 499 small neutral molecules that are modeled using AMBER/GAFF parameters and AM1-BCC charges. Given optimized surface tension coefficients for scaling the surface area term in the nonpolar contribution, most implicit solvent models demonstrate reasonable agreement with extensive explicit solvent simulations (average difference 1.0-1.7 kcal/mol and R2=0.81-0.91) and with experimental hydration free energies (average unsigned errors=1.1-1.4 kcal/mol and R2=0.66-0.81). Chemical classes of compounds are identified that need further optimization of their ligand force field parameters and others that require improvement in the physical parameters of the implicit solvent models themselves. More sophisticated nonpolar models are also likely necessary to more effectively represent the underlying physics of solvation and take the quality of hydration free energies estimated from implicit solvent models to the next level. PMID:21735452

  7. A novel accelerometry-based algorithm for the detection of step durations over short episodes of gait in healthy elderly.

    PubMed

    Micó-Amigo, M Encarna; Kingma, Idsart; Ainsworth, Erik; Walgaard, Stefan; Niessen, Martijn; van Lummel, Rob C; van Dieën, Jaap H

    2016-04-19

    The assessment of short episodes of gait is clinically relevant and easily implemented, especially given limited space and time requirements. BFS (body-fixed-sensors) are small, lightweight and easy to wear sensors, which allow the assessment of gait at relative low cost and with low interference. Thus, the assessment with BFS of short episodes of gait, extracted from dailylife physical activity or measured in a standardised and supervised setting, may add value in the study of gait quality of the elderly. The aim of this study was to evaluate the accuracy of a novel algorithm based on acceleration signals recorded at different human locations (lower back and heels) for the detection of step durations over short episodes of gait in healthy elderly subjects. Twenty healthy elderly subjects (73.7 ± 7.9 years old) walked twice a distance of 5 m, wearing a BFS on the lower back, and on the outside of each heel. Moreover, an optoelectronic three-dimensional (3D) motion tracking system was used to detect step durations. A novel algorithm is presented for the detection of step durations from low-back and heel acceleration signals separately. The accuracy of the algorithm was assessed by comparing absolute differences in step duration between the three methods: step detection from the optoelectronic 3D motion tracking system, step detection from the application of the novel algorithm to low-back accelerations, and step detection from the application of the novel algorithm to heel accelerations. The proposed algorithm successfully detected all the steps, without false positives and without false negatives. Absolute average differences in step duration within trials and across subjects were calculated for each comparison, between low-back accelerations and the optoelectronic system were on average 22.4 ± 7.6 ms (4.0 ± 1.3 % of average step duration), between heel accelerations and the optoelectronic system were on average 20.7 ± 11.8 ms (3.7 ± 1.9 %), and between low-back accelerations and heel accelerations were on average 27.8 ± 15.1 ms (4.9 ± 2.5 % of average step duration). This study showed that the presented novel algorithm detects step durations over short episodes of gait in healthy elderly subjects with acceptable accuracy from low-back and heel accelerations, which provides opportunities to extract a range of gait parameters from short episodes of gait.

  8. Transit dosimetry in IMRT with an a-Si EPID in direct detection configuration

    NASA Astrophysics Data System (ADS)

    Sabet, Mahsheed; Rowshanfarzad, Pejman; Vial, Philip; Menk, Frederick W.; Greer, Peter B.

    2012-08-01

    In this study an amorphous silicon electronic portal imaging device (a-Si EPID) converted to direct detection configuration was investigated as a transit dosimeter for intensity modulated radiation therapy (IMRT). After calibration to dose and correction for a background offset signal, the EPID-measured absolute IMRT transit doses for 29 fields were compared to a MatriXX two-dimensional array of ionization chambers (as reference) using Gamma evaluation (3%, 3 mm). The MatriXX was first evaluated as reference for transit dosimetry. The accuracy of EPID measurements was also investigated by comparison of point dose measurements by an ionization chamber on the central axis with slab and anthropomorphic phantoms in a range of simple to complex fields. The uncertainty in ionization chamber measurements in IMRT fields was also investigated by its displacement from the central axis and comparison with the central axis measurements. Comparison of the absolute doses measured by the EPID and MatriXX with slab phantoms in IMRT fields showed that on average 96.4% and 97.5% of points had a Gamma index<1 in head and neck and prostate fields, respectively. For absolute dose comparisons with anthropomorphic phantoms, the values changed to an average of 93.6%, 93.7% and 94.4% of points with Gamma index<1 in head and neck, brain and prostate fields, respectively. Point doses measured by the EPID and ionization chamber were within 3% difference for all conditions. The deviations introduced in the response of the ionization chamber in IMRT fields were<1%. The direct EPID performance for transit dosimetry showed that it has the potential to perform accurate, efficient and comprehensive in vivo dosimetry for IMRT.

  9. A Statistical Analysis of the Relationship between Harmonic Surprise and Preference in Popular Music.

    PubMed

    Miles, Scott A; Rosen, David S; Grzywacz, Norberto M

    2017-01-01

    Studies have shown that some musical pieces may preferentially activate reward centers in the brain. Less is known, however, about the structural aspects of music that are associated with this activation. Based on the music cognition literature, we propose two hypotheses for why some musical pieces are preferred over others. The first, the Absolute-Surprise Hypothesis, states that unexpected events in music directly lead to pleasure. The second, the Contrastive-Surprise Hypothesis, proposes that the juxtaposition of unexpected events and subsequent expected events leads to an overall rewarding response. We tested these hypotheses within the framework of information theory, using the measure of "surprise." This information-theoretic variable mathematically describes how improbable an event is given a known distribution. We performed a statistical investigation of surprise in the harmonic structure of songs within a representative corpus of Western popular music, namely, the McGill Billboard Project corpus. We found that chords of songs in the top quartile of the Billboard chart showed greater average surprise than those in the bottom quartile. We also found that the different sections within top-quartile songs varied more in their average surprise than the sections within bottom-quartile songs. The results of this study are consistent with both the Absolute- and Contrastive-Surprise Hypotheses. Although these hypotheses seem contradictory to one another, we cannot yet discard the possibility that both absolute and contrastive types of surprise play roles in the enjoyment of popular music. We call this possibility the Hybrid-Surprise Hypothesis. The results of this statistical investigation have implications for both music cognition and the human neural mechanisms of esthetic judgments.

  10. A Statistical Analysis of the Relationship between Harmonic Surprise and Preference in Popular Music

    PubMed Central

    Miles, Scott A.; Rosen, David S.; Grzywacz, Norberto M.

    2017-01-01

    Studies have shown that some musical pieces may preferentially activate reward centers in the brain. Less is known, however, about the structural aspects of music that are associated with this activation. Based on the music cognition literature, we propose two hypotheses for why some musical pieces are preferred over others. The first, the Absolute-Surprise Hypothesis, states that unexpected events in music directly lead to pleasure. The second, the Contrastive-Surprise Hypothesis, proposes that the juxtaposition of unexpected events and subsequent expected events leads to an overall rewarding response. We tested these hypotheses within the framework of information theory, using the measure of “surprise.” This information-theoretic variable mathematically describes how improbable an event is given a known distribution. We performed a statistical investigation of surprise in the harmonic structure of songs within a representative corpus of Western popular music, namely, the McGill Billboard Project corpus. We found that chords of songs in the top quartile of the Billboard chart showed greater average surprise than those in the bottom quartile. We also found that the different sections within top-quartile songs varied more in their average surprise than the sections within bottom-quartile songs. The results of this study are consistent with both the Absolute- and Contrastive-Surprise Hypotheses. Although these hypotheses seem contradictory to one another, we cannot yet discard the possibility that both absolute and contrastive types of surprise play roles in the enjoyment of popular music. We call this possibility the Hybrid-Surprise Hypothesis. The results of this statistical investigation have implications for both music cognition and the human neural mechanisms of esthetic judgments. PMID:28572763

  11. Evaluation of factors affecting CGMS calibration.

    PubMed

    Buckingham, Bruce A; Kollman, Craig; Beck, Roy; Kalajian, Andrea; Fiallo-Scharer, Rosanna; Tansey, Michael J; Fox, Larry A; Wilson, Darrell M; Weinzimer, Stuart A; Ruedy, Katrina J; Tamborlane, William V

    2006-06-01

    The optimal number/timing of calibrations entered into the CGMS (Medtronic MiniMed, Northridge, CA) continuous glucose monitoring system have not been previously described. Fifty subjects with Type 1 diabetes mellitus (10-18 years old) were hospitalized in a clinical research center for approximately 24 h on two separate days. CGMS and OneTouch Ultra meter (LifeScan, Milpitas, CA) data were obtained. The CGMS was retrospectively recalibrated using the Ultra data varying the number and timing of calibrations. Resulting CGMS values were compared against laboratory reference values. There was a modest improvement in accuracy with increasing number of calibrations. The median relative absolute deviation (RAD) was 14%, 15%, 13%, and 13% when using three, four, five, and seven calibration values, respectively (P < 0.001). Corresponding percentages of CGMS-reference pairs meeting the International Organisation for Standardisation criteria were 66%, 67%, 71%, and 72% (P < 0.001). Nighttime accuracy improved when daytime calibrations (pre-lunch and pre-dinner) were removed leaving only two calibrations at 9 p.m. and 6 a.m. (median difference, -2 vs. -9 mg/dL, P < 0.001; median RAD, 12% vs. 15%, P = 0.001). Accuracy was better on visits where the average absolute rate of glucose change at the times of calibration was lower. On visits with average absolute rates <0.5, 0.5 to <1.0, 1.0 to <1.5, and >or=1.5 mg/dL/min, median RAD values were 13% versus 14% versus 17% versus 19%, respectively (P = 0.05). Although accuracy is slightly improved with more calibrations, the timing of the calibrations appears more important. Modifying the algorithm to put less weight on daytime calibrations for nighttime values and calibrating during times of relative glucose stability may have greater impact on accuracy.

  12. Evaluation of Factors Affecting CGMS Calibration

    PubMed Central

    2006-01-01

    Background The optimal number/timing of calibrations entered into the Continuous Glucose Monitoring System (“CGMS”; Medtronic MiniMed, Northridge, CA) have not been previously described. Methods Fifty subjects with T1DM (10–18y) were hospitalized in a clinical research center for ~24h on two separate days. CGMS and OneTouch® Ultra® Meter (“Ultra”; LifeScan, Milpitas, CA) data were obtained. The CGMS was retrospectively recalibrated using the Ultra data varying the number and timing of calibrations. Resulting CGMS values were compared against laboratory reference values. Results There was a modest improvement in accuracy with increasing number of calibrations. The median relative absolute deviation (RAD) was 14%, 15%, 13% and 13% when using 3, 4, 5 and 7 calibration values, respectively (p<0.001). Corresponding percentages of CGMS-reference pairs meeting the ISO criteria were 66%, 67%, 71% and 72% (p<0.001). Nighttime accuracy improved when daytime calibrations (pre-lunch and pre-dinner) were removed leaving only two calibrations at 9p.m. and 6a.m. (median difference: −2 vs. −9mg/dL, p<0.001; median RAD: 12% vs. 15%, p=0.001). Accuracy was better on visits where the average absolute rate of glucose change at the times of calibration was lower. On visits with average absolute rates <0.5, 0.5-<1.0, 1.0-<1.5 and ≥1.5mg/dL/min, median RAD values were 13% vs. 14% vs. 17% vs. 19%, respectively (p=0.05). Conclusions Although accuracy is slightly improved with more calibrations, the timing of the calibrations appears more important. Modifying the algorithm to put less weight on daytime calibrations for nighttime values and calibrating during times of relative glucose stability may have greater impact on accuracy. PMID:16800753

  13. Properties and evolution of near-Earth-object families created by tidal disruption at the Earth

    NASA Astrophysics Data System (ADS)

    Schunova, E.; Walsh, K.; Granvik, M.; Jedicke, R.; Wainscoat, R.; Haghighipour, N.

    2014-07-01

    We have calculated the coherence and detectable lifetimes of synthetic near-Earth object (NEO) families created by catastrophic disruption of a progenitor as it suffers a very close Earth approach. The closest or slowest approaches yield the most violent 'S-class' disruption events and create a 'string of pearls' configuration of the resulting fragments after their reaccummulation into gravitationally bound components [3]. We found that the average absolute magnitude (H) difference between the parent body and the largest fragment is Δ H ˜ 1.0. The average slope of the absolute magnitude (H) distribution, N(H)∝10^{(0.55±0.04) H}, for the fragments in the S-class families is steeper than the slope of the NEO population [2] in the same size range. The families remain coherent as statistically significant clusters of orbits within the NEO population for an average of barτ_c = (14.7±0.6)×10^3 years after disruption. The detectable lifetimes of tidally disrupted families are extremely short compared to the multi-Myr and -Gyr lifetimes of main belt families due to the chaotic dynamical environment in NEO space -- they are detectable with the techniques developed by [1] and [4] for an average duration (barτ_{det}) ranging from about 2,000 to about 12,000 years for progenitors in the absolute magnitude (H_p) range from 20 to 13 corresponding to diameters in the range from about 0.5 to 10 km respectively. The maximum absolute magnitude of a progenitor capable of producing an observable NEO family (i.e. detectable by our family finding technique) is H_{p,max} = 20 (about 350 m diameter). The short detectability lifetime explains why zero NEO families have been discovered to-date. Nonetheless, every tidal disruption event of a progenitor with diameter greater than 0.5 km is capable of producing several million fragments in the 1 m to 10 m diameter range that can contribute to temporary local density enhancements of small NEOs in Earth's vicinity. These objects may be suitable targets for asteroid retrieval missions due to their Earth-like orbits with corresponding low v_∞ which permits low-cost missions. The fragments from the tidal disruptions evolve into orbits that bring them into collision with terrestrial planets or the Sun or they may be ejected from the solar system on hyperbolic orbits due to deep planetary encounters. The end-state for the fragments from a tidal disruption at Earth have ˜5× the collision probability with Earth compared to the background NEO population.

  14. The trading time risks of stock investment in stock price drop

    NASA Astrophysics Data System (ADS)

    Li, Jiang-Cheng; Tang, Nian-Sheng; Mei, Dong-Cheng; Li, Yun-Xian; Zhang, Wan

    2016-11-01

    This article investigates the trading time risk (TTR) of stock investment in the case of stock price drop of Dow Jones Industrial Average (ˆDJI) and Hushen300 data (CSI300), respectively. The escape time of stock price from the maximum to minimum in a data window length (DWL) is employed to measure the absolute TTR, the ratio of the escape time to data window length is defined as the relative TTR. Empirical probability density functions of the absolute and relative TTRs for the ˆDJI and CSI300 data evidence that (i) whenever the DWL increases, the absolute TTR increases, the relative TTR decreases otherwise; (ii) there is the monotonicity (or non-monotonicity) for the stability of the absolute (or relative) TTR; (iii) there is a peak distribution for shorter trading days and a two-peak distribution for longer trading days for the PDF of ratio; (iv) the trading days play an opposite role on the absolute (or relative) TTR and its stability between ˆDJI and CSI300 data.

  15. Money earlier or later? Simple heuristics explain intertemporal choices better than delay discounting does.

    PubMed

    Ericson, Keith M Marzilli; White, John Myles; Laibson, David; Cohen, Jonathan D

    2015-06-01

    Heuristic models have been proposed for many domains involving choice. We conducted an out-of-sample, cross-validated comparison of heuristic models of intertemporal choice (which can account for many of the known intertemporal choice anomalies) and discounting models. Heuristic models outperformed traditional utility-discounting models, including models of exponential and hyperbolic discounting. The best-performing models predicted choices by using a weighted average of absolute differences and relative percentage differences of the attributes of the goods in a choice set. We concluded that heuristic models explain time-money trade-off choices in experiments better than do utility-discounting models. © The Author(s) 2015.

  16. Money Earlier or Later? Simple Heuristics Explain Intertemporal Choices Better than Delay Discounting1

    PubMed Central

    Marzilli Ericson, Keith M.; White, John Myles; Laibson, David; Cohen, Jonathan D.

    2015-01-01

    Heuristic models have been proposed for many domains of choice. We compare heuristic models of intertemporal choice, which can account for many of the known intertemporal choice anomalies, to discounting models. We conduct an out-of-sample, cross-validated comparison of intertemporal choice models. Heuristic models outperform traditional utility discounting models, including models of exponential and hyperbolic discounting. The best performing models predict choices by using a weighted average of absolute differences and relative (percentage) differences of the attributes of the goods in a choice set. We conclude that heuristic models explain time-money tradeoff choices in experiments better than utility discounting models. PMID:25911124

  17. Mapping the Baby Universe

    NASA Technical Reports Server (NTRS)

    Wanjek, Christopher

    2003-01-01

    In June, NASA plans to launch the Microwave Anisotropy Probe (MAP) to survey the ancient radiation in unprecedented detail. MAP will map slight temperature fluctuations within the microwave background that vary by only 0.00001 C across a chilly radiation that now averages 2.73 C above absolute zero. The temperature differences today point back to density differences in the fiery baby universe, in which there was a little more matter here and a little less matter there. Areas of slightly enhanced density had stronger gravity than low-density areas. The high-density areas pulled back on the background radiation, making it appear slightly cooler in those directions.

  18. Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography.

    PubMed

    Amano, Shiro; Honda, Norihiko; Amano, Yuki; Yamagami, Satoru; Miyai, Takashi; Samejima, Tomokazu; Ogata, Miyuki; Miyata, Kazunori

    2006-06-01

    To compare central corneal thickness measurements and their reproducibility when taken by a rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography/pachymetry. Experimental study. Seventy-four eyes of 64 subjects without ocular abnormalities other than cataract. Corneal thickness measurements were compared among the 3 methods in 54 eyes of 54 subjects. Two sets of measurements were repeated by a single examiner for each pachymetry in another 10 eyes of 5 subjects, and the intraexaminer repeatability was assessed as the absolute difference of the first and second measurements. Two experienced examiners took one measurement for each pachymetry in another 10 eyes of 5 subjects, and the interexaminer reproducibility was assessed as the absolute difference of the 2 measurements of the first and second examiners. Central corneal thickness measurements by the 3 methods, absolute difference of the first and second measurements by a single examiner, absolute difference of the 2 measurements by 2 examiners, and relative amount of variation. The average measurements of central corneal thickness by a rotating Scheimpflug camera, scanning-slit topography, and ultrasonic pachymetry were 538+/-31.3 microm, 541+/-40.7 microm, and 545+/-31.3 microm, respectively. There were no statistically significant differences in the measurement results among the 3 methods (P = 0.569, repeated-measures analysis of variance). There was a significant linear correlation between the rotating Scheimpflug camera and ultrasonic pachymetry (r = 0.908, P<0.0001), rotating Scheimpflug camera and scanning-slit topography (r = 0.930, P<0.0001), and ultrasonic pachymetry and scanning-slit topography (r = 0.887, P<0.0001). Ultrasonic pachymetry had the smallest intraexaminer variability, and scanning-slit topography had the largest intraexaminer variability among the 3 methods. There were similar variations in interexaminer reproducibility among the 3 methods. Mean corneal thicknesses were comparable among rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit topography with the acoustic equivalent correction factor. The measurements of the 3 instruments had significant linear correlations with one another, and all methods had highly satisfactory measurement repeatability.

  19. Single-breath diffusing capacity for carbon monoxide instrument accuracy across 3 health systems.

    PubMed

    Hegewald, Matthew J; Markewitz, Boaz A; Wilson, Emily L; Gallo, Heather M; Jensen, Robert L

    2015-03-01

    Measuring diffusing capacity of the lung for carbon monoxide (DLCO) is complex and associated with wide intra- and inter-laboratory variability. Increased D(LCO) variability may have important clinical consequences. The objective of the study was to assess instrument performance across hospital pulmonary function testing laboratories using a D(LCO) simulator that produces precise and repeatable D(LCO) values. D(LCO) instruments were tested with CO gas concentrations representing medium and high range D(LCO) values. The absolute difference between observed and target D(LCO) value was used to determine measurement accuracy; accuracy was defined as an average deviation from the target value of < 2.0 mL/min/mm Hg. Accuracy of inspired volume measurement and gas sensors were also determined. Twenty-three instruments were tested across 3 healthcare systems. The mean absolute deviation from the target value was 1.80 mL/min/mm Hg (range 0.24-4.23) with 10 of 23 instruments (43%) being inaccurate. High volume laboratories performed better than low volume laboratories, although the difference was not significant. There was no significant difference among the instruments by manufacturers. Inspired volume was not accurate in 48% of devices; mean absolute deviation from target value was 3.7%. Instrument gas analyzers performed adequately in all instruments. D(LCO) instrument accuracy was unacceptable in 43% of devices. Instrument inaccuracy can be primarily attributed to errors in inspired volume measurement and not gas analyzer performance. D(LCO) instrument performance may be improved by regular testing with a simulator. Caution should be used when comparing D(LCO) results reported from different laboratories. Copyright © 2015 by Daedalus Enterprises.

  20. [Characteristics of some indicators of physical development and frequency of occurrence of certain somatotypes of women in older age groups].

    PubMed

    Razumov, A N; Vybornaya, K V; Pogonchenkova, I V; Rozhkova, E A; Akyeva, N K; Klochkova, S V; Alekseeva, N T; Nikityuk, D B

    2016-01-01

    The article presents the anthropometric parameters of 251 elderly women (75-90 years) and 125 long-liver women (90-98 years) of the Slavic ethnic group, living in Moscow and Moscow region. Significant differences in basic anthropometric characteristics between two age groups have been demonstrated. Average values of body weight and height, circumferences and quantities of skin-fat folds were significantly lower in long-liver women in compare with representatives of the elderly, whereas diameters had no statistical significant differences. Somatotypological analysis revealed a frequency of occurrence of different somatotypes and prevalence of the three main types among elderly and long-liver women - asthenic (32.2-34.0%), pyknic (29.3-30.0%) and europlastic (20.0-21.2%) somatotype. Some features of body composition characteristics of elderly and long-livers women have been demonstrated as well. Estimated absolute amount of bone compartment did not differ in two women groups, while relative amount of bone compartment in elderly women (15.30±0.21%) was lower by 1.11 fold (p<0.05) than in long-liver women (17.05+±0.17%). The content of fat and muscular body compartment was significantly (p<0.05) lower in long-liver women as compared with the elderly women. The absolute amount of fat body compartment in long-liver women was 9.15±1.22 vs 13.13±0.49 kg in elderly women, the relative amount of fat body compartment - 14.39±0.26 vs 18.04±0.05%; the absolute amount of muscular body compartment - 23.04±0.26 vs 28.06±0.47 kg, the relative amount of fat body compartment - 36.22±0.15 vs 38.54±0.16%.

  1. Evaluating gender similarities and differences using metasynthesis.

    PubMed

    Zell, Ethan; Krizan, Zlatan; Teeter, Sabrina R

    2015-01-01

    Despite the common lay assumption that males and females are profoundly different, Hyde (2005) used data from 46 meta-analyses to demonstrate that males and females are highly similar. Nonetheless, the gender similarities hypothesis has remained controversial. Since Hyde's provocative report, there has been an explosion of meta-analytic interest in psychological gender differences. We utilized this enormous collection of 106 meta-analyses and 386 individual meta-analytic effects to reevaluate the gender similarities hypothesis. Furthermore, we employed a novel data-analytic approach called metasynthesis (Zell & Krizan, 2014) to estimate the average difference between males and females and to explore moderators of gender differences. The average, absolute difference between males and females across domains was relatively small (d = 0.21, SD = 0.14), with the majority of effects being either small (46%) or very small (39%). Magnitude of differences fluctuated somewhat as a function of the psychological domain (e.g., cognitive variables, social and personality variables, well-being), but remained largely constant across age, culture, and generations. These findings provide compelling support for the gender similarities hypothesis, but also underscore conditions under which gender differences are most pronounced. PsycINFO Database Record (c) 2015 APA, all rights reserved.

  2. Forecasting Daily Patient Outflow From a Ward Having No Real-Time Clinical Data

    PubMed Central

    Tran, Truyen; Luo, Wei; Phung, Dinh; Venkatesh, Svetha

    2016-01-01

    Background: Modeling patient flow is crucial in understanding resource demand and prioritization. We study patient outflow from an open ward in an Australian hospital, where currently bed allocation is carried out by a manager relying on past experiences and looking at demand. Automatic methods that provide a reasonable estimate of total next-day discharges can aid in efficient bed management. The challenges in building such methods lie in dealing with large amounts of discharge noise introduced by the nonlinear nature of hospital procedures, and the nonavailability of real-time clinical information in wards. Objective Our study investigates different models to forecast the total number of next-day discharges from an open ward having no real-time clinical data. Methods We compared 5 popular regression algorithms to model total next-day discharges: (1) autoregressive integrated moving average (ARIMA), (2) the autoregressive moving average with exogenous variables (ARMAX), (3) k-nearest neighbor regression, (4) random forest regression, and (5) support vector regression. Although the autoregressive integrated moving average model relied on past 3-month discharges, nearest neighbor forecasting used median of similar discharges in the past in estimating next-day discharge. In addition, the ARMAX model used the day of the week and number of patients currently in ward as exogenous variables. For the random forest and support vector regression models, we designed a predictor set of 20 patient features and 88 ward-level features. Results Our data consisted of 12,141 patient visits over 1826 days. Forecasting quality was measured using mean forecast error, mean absolute error, symmetric mean absolute percentage error, and root mean square error. When compared with a moving average prediction model, all 5 models demonstrated superior performance with the random forests achieving 22.7% improvement in mean absolute error, for all days in the year 2014. Conclusions In the absence of clinical information, our study recommends using patient-level and ward-level data in predicting next-day discharges. Random forest and support vector regression models are able to use all available features from such data, resulting in superior performance over traditional autoregressive methods. An intelligent estimate of available beds in wards plays a crucial role in relieving access block in emergency departments. PMID:27444059

  3. Absolutely relative or relatively absolute: violations of value invariance in human decision making.

    PubMed

    Teodorescu, Andrei R; Moran, Rani; Usher, Marius

    2016-02-01

    Making decisions based on relative rather than absolute information processing is tied to choice optimality via the accumulation of evidence differences and to canonical neural processing via accumulation of evidence ratios. These theoretical frameworks predict invariance of decision latencies to absolute intensities that maintain differences and ratios, respectively. While information about the absolute values of the choice alternatives is not necessary for choosing the best alternative, it may nevertheless hold valuable information about the context of the decision. To test the sensitivity of human decision making to absolute values, we manipulated the intensities of brightness stimuli pairs while preserving either their differences or their ratios. Although asked to choose the brighter alternative relative to the other, participants responded faster to higher absolute values. Thus, our results provide empirical evidence for human sensitivity to task irrelevant absolute values indicating a hard-wired mechanism that precedes executive control. Computational investigations of several modelling architectures reveal two alternative accounts for this phenomenon, which combine absolute and relative processing. One account involves accumulation of differences with activation dependent processing noise and the other emerges from accumulation of absolute values subject to the temporal dynamics of lateral inhibition. The potential adaptive role of such choice mechanisms is discussed.

  4. Income inequality in the developing world.

    PubMed

    Ravallion, Martin

    2014-05-23

    Should income inequality be of concern in developing countries? New data reveal less income inequality in the developing world than 30 years ago. However, this is due to falling inequality between countries. Average inequality within developing countries has been slowly rising, though staying fairly flat since 2000. As a rule, higher rates of growth in average incomes have not put upward pressure on inequality within countries. Growth has generally helped reduce the incidence of absolute poverty, but less so in more unequal countries. High inequality also threatens to stall future progress against poverty by attenuating growth prospects. Perceptions of rising absolute gaps in living standards between the rich and the poor in growing economies are also consistent with the evidence. Copyright © 2014, American Association for the Advancement of Science.

  5. Diagnostic ability of macular ganglion cell asymmetry for glaucoma.

    PubMed

    Hwang, Young Hoon; Ahn, Sang Il; Ko, Sung Ju

    2015-11-01

    Using spectral-domain optical coherence tomography (OCT), this study aims to investigate the glaucoma diagnostic ability of macular ganglion cell asymmetry analysis. A cross-sectional study was conducted. This study was performed to investigate glaucoma diagnostic ability of macular ganglion cell asymmetry analysis in eyes with various degrees of glaucoma. We enrolled 181 healthy eyes and 265 glaucomatous eyes. Glaucomatous eyes were subdivided into pre-perimetric, early, moderate and advanced-to-severe glaucoma based on visual field test results. For each eye, macular ganglion cell-inner plexiform layer (GCIPL) thickness was measured using OCT. Average GCIPL thickness, GCIPL thicknesses in superior and inferior hemispheres, absolute difference in GCIPL thickness between superior and inferior hemispheres and GCIPL asymmetry index calculated as the absolute value of log10 (inferior hemisphere thickness/superior hemisphere thickness) were analysed. Areas under the receiver operating characteristics curves (AUCs) of GCIPL parameter were calculated and compared. All of the GCIPL parameters showed good glaucoma diagnostic ability (AUCs ≥ 0.817, P < 0.01). AUCs of average, superior and inferior GCIPL thickness increased as the severity of glaucoma increased. GCIPL thickness difference and asymmetry index showed the highest AUCs in early and moderate glaucoma and lower AUCs in pre-perimetric and advanced-to-severe glaucoma. GCIPL thickness difference and asymmetry index showed better glaucoma diagnostic ability than other GCIPL parameters only in early stage of glaucoma (P < 0.05); in other stages, these parameters had similar to or worse glaucoma diagnostic ability than other GCIPL parameters. Macular ganglion cell asymmetry analysis showed good glaucoma diagnostic ability, especially in early-stage glaucoma. However, it has limited usefulness in other stages of glaucoma. © 2015 Royal Australian and New Zealand College of Ophthalmologists.

  6. A gravimetric method for the measurement of total spontaneous activity in rats.

    PubMed

    Biesiadecki, B J; Brand, P H; Koch, L G; Britton, S L

    1999-10-01

    Currently available methods for the measurement of spontaneous activity of laboratory animals require expensive, specialized equipment and may not be suitable for use in low light conditions with nocturnal species. We developed a gravimetric method that uses common laboratory equipment to quantify the total spontaneous activity of rats and is suitable for use in the dark. The rat in its home cage is placed on a top-loading electronic balance interfaced to a computer. Movements are recorded by the balance as changes in weight and transmitted to the computer at 10 Hz. Data are analyzed on-line to derive the absolute value of the difference in weight between consecutive samples, and the one-second average of the absolute values is calculated. The averages are written to file for off-line analysis and summed over the desired observation period to provide a measure of total spontaneous activity. The results of in vitro experiments demonstrated that: 1) recorded weight changes were not influenced by position of the weight on the bottom of the cage, 2) values recorded from a series of weight changes were not significantly different from the calculated values, 3) the constantly decreasing force exerted by a swinging pendulum placed on the balance was accurately recorded, 4) the measurement of activity was not influenced by the evaporation of a fluid such as urine, and 5) the method can detect differences in the activity of sleeping and waking rats over a 10-min period, as well as during 4-hr intervals recorded during active (night-time) and inactive (daytime) periods. These results demonstrate that this method provides an inexpensive, accurate, and noninvasive method to quantitate the spontaneous activity of small animals.

  7. An assessment of differences in gridded precipitation datasets in complex terrain

    NASA Astrophysics Data System (ADS)

    Henn, Brian; Newman, Andrew J.; Livneh, Ben; Daly, Christopher; Lundquist, Jessica D.

    2018-01-01

    Hydrologic modeling and other geophysical applications are sensitive to precipitation forcing data quality, and there are known challenges in spatially distributing gauge-based precipitation over complex terrain. We conduct a comparison of six high-resolution, daily and monthly gridded precipitation datasets over the Western United States. We compare the long-term average spatial patterns, and interannual variability of water-year total precipitation, as well as multi-year trends in precipitation across the datasets. We find that the greatest absolute differences among datasets occur in high-elevation areas and in the maritime mountain ranges of the Western United States, while the greatest percent differences among datasets relative to annual total precipitation occur in arid and rain-shadowed areas. Differences between datasets in some high-elevation areas exceed 200 mm yr-1 on average, and relative differences range from 5 to 60% across the Western United States. In areas of high topographic relief, true uncertainties and biases are likely higher than the differences among the datasets; we present evidence of this based on streamflow observations. Precipitation trends in the datasets differ in magnitude and sign at smaller scales, and are sensitive to how temporal inhomogeneities in the underlying precipitation gauge data are handled.

  8. Dynamic phenotypic restructuring of the CD4 and CD8 T-cell subsets with age in healthy humans: a compartmental model analysis.

    PubMed

    Jackola, D R; Hallgren, H M

    1998-11-16

    In healthy humans, phenotypic restructuring occurs with age within the CD3+ T-lymphocyte complement. This is characterized by a non-linear decrease of the percentage of 'naive' (CD45RA+) cells and a corresponding non-linear increase of the percentage of 'memory' (CD45R0+) cells among both the CD4+ and CD8+ T-cell subsets. We devised a simple compartmental model to study the age-dependent kinetics of phenotypic restructuring. We also derived differential equations whose parameters determined yearly gains minus losses of the percentage and absolute numbers of circulating naive cells, yearly gains minus losses of the percentage and absolute numbers of circulating memory cells, and the yearly rate of conversion of naive to memory cells. Solutions of these evaluative differential equations demonstrate the following: (1) the memory cell complement 'resides' within its compartment for a longer time than the naive cell complement within its compartment for both CD4 and CD8 cells; (2) the average, annual 'turnover rate' is the same for CD4 and CD8 naive cells. In contrast, the average, annual 'turnover rate' for memory CD8 cells is 1.5 times that of memory CD4 cells; (3) the average, annual conversion rate of CD4 naive cells to memory cells is twice that of the CD8 conversion rate; (4) a transition in dynamic restructuring occurs during the third decade of life that is due to these differences in turnover and conversion rates, between and from naive to memory cells.

  9. Statistical distribution of foveal transverse chromatic aberration, pupil centration, and angle psi in a population of young adult eyes

    NASA Astrophysics Data System (ADS)

    Rynders, Maurice; Lidkea, Bruce; Chisholm, William; Thibos, Larry N.

    1995-10-01

    Subjective transverse chromatic aberration (sTCA) manifest at the fovea was determined for a population of 85 young adults (19-38 years old) by means of a two-dimensional, two-color, vernier alignment technique. The statistical distribution of sTCA was well fitted by a bivariate Gaussian function with mean values that were not significantly different from zero in either the horizontal or the vertical direction. We conclude from this result that a hypothetical, average eye representing the population mean of human eyes with medium-sized pupils is free of foveal sTCA. However, the absolute magnitude of sTCA for any given individual was often significantly greater than zero and ranged from 0.05 to 2.67 arcmin for the red and the blue lights of a computer monitor (mean wavelengths, 605 and 497 nm, respectively). The statistical distribution of the absolute magnitude of sTCA was well described by a Rayleigh probability distribution with a mean of 0.8 arcmin. A simple device useful for population screening in a clinical setting was also tested and gave concordant results. Assuming that sTCA at the fovea is due to decentering of the pupil with respect to the visual axis, we infer from these results that the pupil is, on average, well centered in human eyes. The average magnitude of pupil decentration in individual eyes is less than 0.5 mm, which corresponds to psi =3 deg for the angle between the achromatic and the visual axes of the eye.

  10. Estimation of rhG-CSF absorption kinetics after subcutaneous administration using a modified Wagner-Nelson method with a nonlinear elimination model.

    PubMed

    Hayashi, N; Aso, H; Higashida, M; Kinoshita, H; Ohdo, S; Yukawa, E; Higuchi, S

    2001-05-01

    The clearance of recombinant human granulocyte-colony stimulating factor (rhG-CSF) is known to decrease with dose increase, and to be saturable. The average clearance after intravenous administration will be lower than that after subcutaneous administration. Therefore, the apparent absolute bioavailability with subcutaneous administration calculated from the AUC ratio is expected to be an underestimate. The absorption pharmacokinetics after subcutaneous administration was examined using the results of the bioequivalency study between two rhG-CSF formulations with a dose of 2 microg/kg. The analysis was performed using a modified Wagner-Nelson method with the nonlinear elimination model. The apparent absolute bioavailability for subcutaneous administration was 56.9 and 67.5% for each formulation, and the ratio between them was approximately 120%. The true absolute bioavailability was, however, estimated to be 89.8 and 96.9%, respectively, and the ratio was approximately 108%. The absorption pattern was applied to other doses, and the predicted clearance values for subcutaneous and intravenous administrations were then similar to the values for several doses reported in the literature. The underestimation of bioavailability was around 30%, and the amplification of difference was 2.5 times, from 8 to 20%, because of the nonlinear pharmacokinetics. The neutrophil increases for each formulation were identical, despite the different bioavailabilities. The reason for this is probably that the amount eliminated through the saturable process, which might indicate the amount consumed by the G-CSF receptor, was identical for each formulation.

  11. A multicentre audit of HDR/PDR brachytherapy absolute dosimetry in association with the INTERLACE trial (NCT015662405)

    NASA Astrophysics Data System (ADS)

    Díez, P.; Aird, E. G. A.; Sander, T.; Gouldstone, C. A.; Sharpe, P. H. G.; Lee, C. D.; Lowe, G.; Thomas, R. A. S.; Simnor, T.; Bownes, P.; Bidmead, M.; Gandon, L.; Eaton, D.; Palmer, A. L.

    2017-12-01

    A UK multicentre audit to evaluate HDR and PDR brachytherapy has been performed using alanine absolute dosimetry. This is the first national UK audit performing an absolute dose measurement at a clinically relevant distance (20 mm) from the source. It was performed in both INTERLACE (a phase III multicentre trial in cervical cancer) and non-INTERLACE brachytherapy centres treating gynaecological tumours. Forty-seven UK centres (including the National Physical Laboratory) were visited. A simulated line source was generated within each centre’s treatment planning system and dwell times calculated to deliver 10 Gy at 20 mm from the midpoint of the central dwell (representative of Point A of the Manchester system). The line source was delivered in a water-equivalent plastic phantom (Barts Solid Water) encased in blocks of PMMA (polymethyl methacrylate) and charge measured with an ion chamber at 3 positions (120° apart, 20 mm from the source). Absorbed dose was then measured with alanine at the same positions and averaged to reduce source positional uncertainties. Charge was also measured at 50 mm from the source (representative of Point B of the Manchester system). Source types included 46 HDR and PDR 192Ir sources, (7 Flexisource, 24 mHDR-v2, 12 GammaMed HDR Plus, 2 GammaMed PDR Plus, 1 VS2000) and 1 HDR 60Co source, (Co0.A86). Alanine measurements when compared to the centres’ calculated dose showed a mean difference (±SD) of  +1.1% (±1.4%) at 20 mm. Differences were also observed between source types and dose calculation algorithm. Ion chamber measurements demonstrated significant discrepancies between the three holes mainly due to positional variation of the source within the catheter (0.4%-4.9% maximum difference between two holes). This comprehensive audit of absolute dose to water from a simulated line source showed all centres could deliver the prescribed dose to within 5% maximum difference between measurement and calculation.

  12. Modeling of the influence of humidity on H1N1 flu in China

    NASA Astrophysics Data System (ADS)

    PEI, Y.; Tian, H.; Xu, B.

    2015-12-01

    In 2009, a heavy Flu hit the whole world. It was caused by the virus H1N1. The influenza first broke out in Mexico in March and the United States in April, 2009. The World Health Organization (WHO) announced that the H1N1 influenza became pandemic, alert to a warning phase of six. By the end of 2011, 181302 H1N1 cases were reported in mainland China. To improve our understanding on the impact of environmental factors on the disease transmission, we constructed an SIR (Susceptible - Infectious - Recovered) model incorporating environmental factors. It was found that the absolute humidity was a dominant environmental factor. The study interpolated the humidity data monitored with 340 weather stations from 1951 to 2011 in mainland China. First, the break point of the trend for the absolutely humidity was detected by the BFAST (Break For Additive Season and Trend) method. Then, the SIR model with and without the absolutely humidity incorporated in the model was built and tested. Finally, the results with the two scenarios were compared. Results indicate that lower absolutely humidity may promote the transmission of the H1N1 cases. The calculated basic reproductive number ranges from 1.65 to 3.66 with a changing absolute humidity. This is consistent with the former study result with basic reproductive number ranging from 2.03 to 4.18. The average recovery duration was estimated to be 5.7 days. The average duration to get immunity from the influenza is 399.02 days. A risk map is also produced to illustrate the model results.

  13. Comparison of tropospheric NO2 vertical columns in an urban environment using satellite, multi-axis differential optical absorption spectroscopy, and in situ measurements

    NASA Astrophysics Data System (ADS)

    Mendolia, D.; D'Souza, R. J. C.; Evans, G. J.; Brook, J.

    2013-10-01

    Tropospheric NO2 vertical column densities have been retrieved and compared for the first time in Toronto, Canada, using three methods of differing spatial scales. Remotely sensed NO2 vertical column densities, retrieved from multi-axis differential optical absorption spectroscopy and satellite remote sensing, were evaluated by comparison with in situ vertical column densities estimated using a pair of chemiluminescence monitors situated 0.01 and 0.5 km a.g.l. (above ground level). The chemiluminescence measurements were corrected for the influence of NOz, which reduced the NO2 concentrations at 0.01 and 0.5 km by an average of 8 ± 1% and 12 ± 1%, respectively. The average absolute decrease in the chemiluminescence NO2 measurement as a result of this correction was less than 1 ppb. The monthly averaged ratio of the NO2 concentration at 0.5 to 0.01 km varied seasonally, and exhibited a negative linear dependence on the monthly average temperature, with Pearson's R = 0.83. During the coldest month, February, this ratio was 0.52 ± 0.04, while during the warmest month, July, this ratio was 0.34 ± 0.04, illustrating that NO2 is not well mixed within 0.5 km above ground level. Good correlation was observed between the remotely sensed and in situ NO2 vertical column densities (Pearson's R value ranging from 0.72 to 0.81), but the in situ vertical column densities were 52 to 58% greater than the remotely sensed columns. These results indicate that NO2 horizontal heterogeneity strongly impacted the magnitude of the remotely sensed columns. The in situ columns reflected an urban environment with major traffic sources, while the remotely sensed NO2 vertical column densities were representative of the region, which included spatial heterogeneity introduced by residential neighbourhoods and Lake Ontario. Despite the difference in absolute values, the reasonable correlation between the vertical column densities determined by three distinct methods increased confidence in the validity of the values provided by each measurement technique.

  14. Calibration of diffuse correlation spectroscopy blood flow index with venous-occlusion diffuse optical spectroscopy in skeletal muscle

    PubMed Central

    Li, Zhe; Baker, Wesley B.; Parthasarathy, Ashwin B.; Ko, Tiffany S.; Wang, Detian; Schenkel, Steven; Durduran, Turgut; Li, Gang; Yodh, Arjun G.

    2015-01-01

    Abstract. We investigate and assess the utility of a simple scheme for continuous absolute blood flow monitoring based on diffuse correlation spectroscopy (DCS). The scheme calibrates DCS using venous-occlusion diffuse optical spectroscopy (VO-DOS) measurements of arm muscle tissue at a single time-point. A calibration coefficient (γ) for the arm is determined, permitting conversion of DCS blood flow indices to absolute blood flow units, and a study of healthy adults (N=10) is carried out to ascertain the variability of γ. The average DCS calibration coefficient for the right (i.e., dominant) arm was γ=(1.24±0.15)×108 (mL·100  mL−1·min−1)/(cm2/s). However, variability can be significant and is apparent in our site-to-site and day-to-day repeated measurements. The peak hyperemic blood flow overshoot relative to baseline resting flow was also studied following arm-cuff ischemia; excellent agreement between VO-DOS and DCS was found (R2=0.95, slope=0.94±0.07, mean difference=−0.10±0.45). Finally, we show that incorporation of subject-specific absolute optical properties significantly improves blood flow calibration accuracy. PMID:26720870

  15. Reproducibility, Reliability, and Validity of Fuchsin-Based Beads for the Evaluation of Masticatory Performance.

    PubMed

    Sánchez-Ayala, Alfonso; Farias-Neto, Arcelino; Vilanova, Larissa Soares Reis; Costa, Marina Abrantes; Paiva, Ana Clara Soares; Carreiro, Adriana da Fonte Porto; Mestriner-Junior, Wilson

    2016-08-01

    Rehabilitation of masticatory function is inherent to prosthodontics; however, despite the various techniques for evaluating oral comminution, the methodological suitability of these has not been completely studied. The aim of this study was to determine the reproducibility, reliability, and validity of a test food based on fuchsin beads for masticatory function assessment. Masticatory performance was evaluated in 20 dentate subjects (mean age, 23.3 years) using two kinds of test foods and methods: fuchsin beads and ultraviolet-visible spectrophotometry, and silicone cubes and multiple sieving as gold standard. Three examiners conducted five masticatory performance trials with each test food. Reproducibility of the results from both test foods was separately assessed using the intraclass correlation coefficient (ICC). Reliability and validity of fuchsin bead data were measured by comparing the average mean of absolute differences and the measurement means, respectively, regarding silicone cube data using the paired Student's t-test (α = 0.05). Intraexaminer and interexaminer ICC for the fuchsin bead values were 0.65 and 0.76 (p < 0.001), respectively; those for the silicone cubes values were 0.93 and 0.91 (p < 0.001), respectively. Reliability revealed intraexaminer (p < 0.001) and interexaminer (p < 0.05) differences between the average means of absolute differences of each test foods. Validity also showed differences between the measurement means of each test food (p < 0.001). Intra- and interexaminer reproducibility of the test food based on fuchsin beads for evaluation of masticatory performance were good and excellent, respectively; however, the reliability and validity were low, because fuchsin beads do not measure the grinding capacity of masticatory function as silicone cubes do; instead, this test food describes the crushing potential of teeth. Thus, the two kinds of test foods evaluate different properties of masticatory capacity, confirming fushsin beads as a useful tool for this purpose. © 2015 by the American College of Prosthodontists.

  16. Matching methods evaluation framework for stereoscopic breast x-ray images.

    PubMed

    Rousson, Johanna; Naudin, Mathieu; Marchessoux, Cédric

    2016-01-01

    Three-dimensional (3-D) imaging has been intensively studied in the past few decades. Depth information is an important added value of 3-D systems over two-dimensional systems. Special focuses were devoted to the development of stereo matching methods for the generation of disparity maps (i.e., depth information within a 3-D scene). Dedicated frameworks were designed to evaluate and rank the performance of different stereo matching methods but never considering x-ray medical images. Yet, 3-D x-ray acquisition systems and 3-D medical displays have already been introduced into the diagnostic market. To access the depth information within x-ray stereoscopic images, computing accurate disparity maps is essential. We aimed at developing a framework dedicated to x-ray stereoscopic breast images used to evaluate and rank several stereo matching methods. A multiresolution pyramid optimization approach was integrated to the framework to increase the accuracy and the efficiency of the stereo matching techniques. Finally, a metric was designed to score the results of the stereo matching compared with the ground truth. Eight methods were evaluated and four of them [locally scaled sum of absolute differences (LSAD), zero mean sum of absolute differences, zero mean sum of squared differences, and locally scaled mean sum of squared differences] appeared to perform equally good with an average error score of 0.04 (0 is the perfect matching). LSAD was selected for generating the disparity maps.

  17. Interrater and intrarater agreements of magnetic resonance imaging findings in the lumbar spine: significant variability across degenerative conditions.

    PubMed

    Fu, Michael C; Buerba, Rafael A; Long, William D; Blizzard, Daniel J; Lischuk, Andrew W; Haims, Andrew H; Grauer, Jonathan N

    2014-10-01

    Magnetic resonance imaging (MRI) is frequently used in the evaluation of degenerative conditions in the lumbar spine. The relative interrater and intrarater agreements of MRI findings across different pathologic conditions are underexplored, as most studies are focused on specific findings. The purpose of this study was to characterize the interrater and intrarater agreements of MRI findings used to assess the degenerative lumbar spine. A retrospective diagnostic study at a large academic medical center was undertaken with a panel of orthopedic surgeons and musculoskeletal radiologists to assess lumbar MRIs using standardized criteria. Seventy-five subjects who underwent routine lumbar spine MRI at our institution were included. Each MRI study was assessed for 10 lumbar degenerative findings using standardized criteria. Lumbar vertebral levels were assessed independently, where applicable, for a total of 52 data points collected per study. T2-weighted axial and sagittal MRI sequences were presented in random order to the four reviewers (two orthopedic spine surgeons and two musculoskeletal radiologists) independently to determine interrater agreement. The first 10 studies were reevaluated at the end to determine intrarater agreement. Images were assessed using standardized and pilot-tested criteria to assess disc degeneration, stenosis, and other degenerative changes. Interrater and intrarater absolute percent agreements were calculated. To highlight the most clinically important MRI disagreements, a modified agreement analysis was also performed (in which disagreements between the lowest two severity grades for applicable conditions were ignored). Fleiss kappa coefficients for interrater agreement were determined. The overall absolute and modified interrater agreements were 76.9% and 93.5%, respectively. The absolute and modified intrarater agreements were 81.3% and 92.7%, respectively. Average Fleiss kappa coefficient was 0.431, suggesting moderate overall agreement. However, when stratified by condition, absolute interrater agreement ranged from 65.1% to 92.0%. Disc hydration, disc space height, and bone marrow changes exhibited the lowest absolute interrater agreements. The absolute intrarater agreement had a narrower range, from 74.5% to 91.5%. Fleiss kappa coefficients ranged from fair-to-substantial agreement (0.282-0.618). Even in a study using standardized evaluation criteria, there was significant variability in the interrater and intrarater agreements of MRI in assessing different degenerative conditions of the lumbar spine. Clinicians should be aware of the condition-specific diagnostic limitations of MRI interpretation. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Documentation of a groundwater flow model developed to assess groundwater availability in the Northern Atlantic Coastal Plain aquifer system from Long Island, New York, to North Carolina

    USGS Publications Warehouse

    Masterson, John P.; Pope, Jason P.; Fienen, Michael N.; Monti, Jr., Jack; Nardi, Mark R.; Finkelstein, Jason S.

    2016-08-31

    The U.S. Geological Survey developed a groundwater flow model for the Northern Atlantic Coastal Plain aquifer system from Long Island, New York, to northeastern North Carolina as part of a detailed assessment of the groundwater availability of the area and included an evaluation of how these resources have changed over time from stresses related to human uses and climate trends. The assessment was necessary because of the substantial dependency on groundwater for agricultural, industrial, and municipal needs in this area.The three-dimensional, groundwater flow model developed for this investigation used the numerical code MODFLOW–NWT to represent changes in groundwater pumping and aquifer recharge from predevelopment (before 1900) to future conditions, from 1900 to 2058. The model was constructed using existing hydrogeologic and geospatial information to represent the aquifer system geometry, boundaries, and hydraulic properties of the 19 separate regional aquifers and confining units within the Northern Atlantic Coastal Plain aquifer system and was calibrated using an inverse modeling parameter-estimation (PEST) technique.The parameter estimation process was achieved through history matching, using observations of heads and flows for both steady-state and transient conditions. A total of 8,868 annual water-level observations from 644 wells from 1986 to 2008 were combined into 29 water-level observation groups that were chosen to focus the history matching on specific hydrogeologic units in geographic areas in which distinct geologic and hydrologic conditions were observed. In addition to absolute water-level elevations, the water-level differences between individual measurements were also included in the parameter estimation process to remove the systematic bias caused by missing hydrologic stresses prior to 1986. The total average residual of –1.7 feet was normally distributed for all head groups, indicating minimal bias. The average absolute residual value of 12.3 feet is about 3 percent of the total observed water-level range throughout the aquifer system.Streamflow observation data of base flow conditions were derived for 153 sites from the U.S. Geological Survey National Hydrography Dataset Plus and National Water Information System. An average residual of about –8 cubic feet per second and an average absolute residual of about 21 cubic feet per second for a range of computed base flows of about 417 cubic feet per second were calculated for the 122 sites from the National Hydrography Dataset Plus. An average residual of about 10 cubic feet per second and an average absolute residual of about 34 cubic feet per second were calculated for the 568 flow measurements in the 31 sites obtained from the National Water Information System for a range in computed base flows of about 1,141 cubic feet per second.The numerical representation of the hydrogeologic information used in the development of this regional flow model was dependent upon how the aquifer system and simulated hydrologic stresses were discretized in space and time. Lumping hydraulic parameters in space and hydrologic stresses and time-varying observational data in time can limit the capabilities of this tool to simulate how the groundwater flow system responds to changes in hydrologic stresses, particularly at the local scale.

  19. Gravitational acceleration as a cue for absolute size and distance?

    NASA Technical Reports Server (NTRS)

    Hecht, H.; Kaiser, M. K.; Banks, M. S.

    1996-01-01

    When an object's motion is influenced by gravity, as in the rise and fall of a thrown ball, the vertical component of acceleration is roughly constant at 9.8 m/sec2. In principle, an observer could use this information to estimate the absolute size and distance of the object (Saxberg, 1987a; Watson, Banks, von Hofsten, & Royden, 1992). In five experiments, we examined people's ability to utilize the size and distance information provided by gravitational acceleration. Observers viewed computer simulations of an object rising and falling on a trajectory aligned with the gravitational vector. The simulated objects were balls of different diameters presented across a wide range of simulated distances. Observers were asked to identify the ball that was presented and to estimate its distance. The results showed that observers were much more sensitive to average velocity than to the gravitational acceleration pattern. Likewise, verticality of the motion and visibility of the trajectory's apex had negligible effects on the accuracy of size and distance judgments.

  20. The absolute amplitude calibration of the SEASAT synthetic aperture radar - An intercomparison with other L-band radar systems

    NASA Technical Reports Server (NTRS)

    Held, D.; Werner, C.; Wall, S.

    1983-01-01

    The absolute amplitude calibration of the spaceborne Seasat SAR data set is presented based on previous relative calibration studies. A scale factor making it possible to express the perceived radar brightness of a scene in units of sigma-zero is established. The system components are analyzed for error contribution, and the calibration techniques are introduced for each stage. These include: A/D converter saturation tests; prevention of clipping in the processing step; and converting the digital image into the units of received power. Experimental verification was performed by screening and processing the data of the lava flow surrounding the Pisgah Crater in Southern California, for which previous C-130 airborne scatterometer data were available. The average backscatter difference between the two data sets is estimated to be 2 dB in the brighter, and 4 dB in the dimmer regions. For the SAR a calculated uncertainty of 3 dB is expected.

  1. An absolute interval scale of order for point patterns

    PubMed Central

    Protonotarios, Emmanouil D.; Baum, Buzz; Johnston, Alan; Hunter, Ginger L.; Griffin, Lewis D.

    2014-01-01

    Human observers readily make judgements about the degree of order in planar arrangements of points (point patterns). Here, based on pairwise ranking of 20 point patterns by degree of order, we have been able to show that judgements of order are highly consistent across individuals and the dimension of order has an interval scale structure spanning roughly 10 just-notable-differences (jnd) between disorder and order. We describe a geometric algorithm that estimates order to an accuracy of half a jnd by quantifying the variability of the size and shape of spaces between points. The algorithm is 70% more accurate than the best available measures. By anchoring the output of the algorithm so that Poisson point processes score on average 0, perfect lattices score 10 and unit steps correspond closely to jnds, we construct an absolute interval scale of order. We demonstrate its utility in biology by using this scale to quantify order during the development of the pattern of bristles on the dorsal thorax of the fruit fly. PMID:25079866

  2. 9 CFR 439.20 - Criteria for maintaining accreditation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...

  3. 9 CFR 439.20 - Criteria for maintaining accreditation.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...

  4. 9 CFR 439.20 - Criteria for maintaining accreditation.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...

  5. 9 CFR 439.20 - Criteria for maintaining accreditation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...

  6. 9 CFR 439.20 - Criteria for maintaining accreditation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...

  7. Accuracy evaluation of intraoral optical impressions: A clinical study using a reference appliance.

    PubMed

    Atieh, Mohammad A; Ritter, André V; Ko, Ching-Chang; Duqum, Ibrahim

    2017-09-01

    Trueness and precision are used to evaluate the accuracy of intraoral optical impressions. Although the in vivo precision of intraoral optical impressions has been reported, in vivo trueness has not been evaluated because of limitations in the available protocols. The purpose of this clinical study was to compare the accuracy (trueness and precision) of optical and conventional impressions by using a novel study design. Five study participants consented and were enrolled. For each participant, optical and conventional (vinylsiloxanether) impressions of a custom-made intraoral Co-Cr alloy reference appliance fitted to the mandibular arch were obtained by 1 operator. Three-dimensional (3D) digital models were created for stone casts obtained from the conventional impression group and for the reference appliances by using a validated high-accuracy reference scanner. For the optical impression group, 3D digital models were obtained directly from the intraoral scans. The total mean trueness of each impression system was calculated by averaging the mean absolute deviations of the impression replicates from their 3D reference model for each participant, followed by averaging the obtained values across all participants. The total mean precision for each impression system was calculated by averaging the mean absolute deviations between all the impression replicas for each participant (10 pairs), followed by averaging the obtained values across all participants. Data were analyzed using repeated measures ANOVA (α=.05), first to assess whether a systematic difference in trueness or precision of replicate impressions could be found among participants and second to assess whether the mean trueness and precision values differed between the 2 impression systems. Statistically significant differences were found between the 2 impression systems for both mean trueness (P=.010) and mean precision (P=.007). Conventional impressions had higher accuracy with a mean trueness of 17.0 ±6.6 μm and mean precision of 16.9 ±5.8 μm than optical impressions with a mean trueness of 46.2 ±11.4 μm and mean precision of 61.1 ±4.9 μm. Complete arch (first molar-to-first molar) optical impressions were less accurate than conventional impressions but may be adequate for quadrant impressions. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Absolute distance measurement by dual-comb interferometry with multi-channel digital lock-in phase detection

    NASA Astrophysics Data System (ADS)

    Yang, Ruitao; Pollinger, Florian; Meiners-Hagen, Karl; Krystek, Michael; Tan, Jiubin; Bosse, Harald

    2015-08-01

    We present a dual-comb-based heterodyne multi-wavelength absolute interferometer capable of long distance measurements. The phase information of the various comb modes is extracted in parallel by a multi-channel digital lock-in phase detection scheme. Several synthetic wavelengths of the same order are constructed and the corresponding phases are averaged to deduce the absolute lengths with significantly reduced uncertainty. Comparison experiments with an incremental HeNe reference interferometer show a combined relative measurement uncertainty of 5.3 × 10-7 at a measurement distance of 20 m. Combining the advantage of synthetic wavelength interferometry and dual-comb interferometry, our compact and simple approach provides sufficient precision for many industrial applications.

  9. Gamut Volume Index: a color preference metric based on meta-analysis and optimized colour samples.

    PubMed

    Liu, Qiang; Huang, Zheng; Xiao, Kaida; Pointer, Michael R; Westland, Stephen; Luo, M Ronnier

    2017-07-10

    A novel metric named Gamut Volume Index (GVI) is proposed for evaluating the colour preference of lighting. This metric is based on the absolute gamut volume of optimized colour samples. The optimal colour set of the proposed metric was obtained by optimizing the weighted average correlation between the metric predictions and the subjective ratings for 8 psychophysical studies. The performance of 20 typical colour metrics was also investigated, which included colour difference based metrics, gamut based metrics, memory based metrics as well as combined metrics. It was found that the proposed GVI outperformed the existing counterparts, especially for the conditions where correlated colour temperatures differed.

  10. Mechanistic approach to generalized technical analysis of share prices and stock market indices

    NASA Astrophysics Data System (ADS)

    Ausloos, M.; Ivanova, K.

    2002-05-01

    Classical technical analysis methods of stock evolution are recalled, i.e. the notion of moving averages and momentum indicators. The moving averages lead to define death and gold crosses, resistance and support lines. Momentum indicators lead the price trend, thus give signals before the price trend turns over. The classical technical analysis investment strategy is thereby sketched. Next, we present a generalization of these tricks drawing on physical principles, i.e. taking into account not only the price of a stock but also the volume of transactions. The latter becomes a time dependent generalized mass. The notion of pressure, acceleration and force are deduced. A generalized (kinetic) energy is easily defined. It is understood that the momentum indicators take into account the sign of the fluctuations, while the energy is geared toward the absolute value of the fluctuations. They have different patterns which are checked by searching for the crossing points of their respective moving averages. The case of IBM evolution over 1990-2000 is used for illustrations.

  11. Twenty Years of Progress on Maternal and Child Health in the Philippines: An Equity Lens.

    PubMed

    Bredenkamp, Caryn; Buisman, Leander R

    2017-07-01

    This article assesses trends and inequalities in maternal and child health in the Philippines between 1993 and 2013, using 6 national household surveys, and also compares the Philippines' performance to 15 other Asia-Pacific countries. Thirteen indicators of child health outcomes and maternal and child health interventions are examined. Two measures of inequality are used: the absolute difference between the poorest and wealthiest quintile, and the concentration index. Coverage of all indicators has improved, both on average and among the poorest quintile; however, increases are very small for child health interventions (especially immunization coverage). By the first measure of inequality, all indicators show narrowing inequalities. By the second measure, inequality has fallen only for maternal health interventions. Compared with other 15 other developing Asia-Pacific countries, the Philippines performs among the best on the child health outcomes examined and above average on maternal health interventions (except family planning), but only at or below average on child health interventions.

  12. Time-series modeling and prediction of global monthly absolute temperature for environmental decision making

    NASA Astrophysics Data System (ADS)

    Ye, Liming; Yang, Guixia; Van Ranst, Eric; Tang, Huajun

    2013-03-01

    A generalized, structural, time series modeling framework was developed to analyze the monthly records of absolute surface temperature, one of the most important environmental parameters, using a deterministicstochastic combined (DSC) approach. Although the development of the framework was based on the characterization of the variation patterns of a global dataset, the methodology could be applied to any monthly absolute temperature record. Deterministic processes were used to characterize the variation patterns of the global trend and the cyclic oscillations of the temperature signal, involving polynomial functions and the Fourier method, respectively, while stochastic processes were employed to account for any remaining patterns in the temperature signal, involving seasonal autoregressive integrated moving average (SARIMA) models. A prediction of the monthly global surface temperature during the second decade of the 21st century using the DSC model shows that the global temperature will likely continue to rise at twice the average rate of the past 150 years. The evaluation of prediction accuracy shows that DSC models perform systematically well against selected models of other authors, suggesting that DSC models, when coupled with other ecoenvironmental models, can be used as a supplemental tool for short-term (˜10-year) environmental planning and decision making.

  13. Dust-Corrected Star Formation Rates in Galaxies with Outer Rings

    NASA Astrophysics Data System (ADS)

    Kostiuk, I.; Silchenko, O.

    2018-03-01

    The star formation rates SFR, as well as the SFR surface densities ΣSFR and absolute stellar magnitudes MAB, are determined and corrected for interinsic dust absorption for 34 disk galaxies of early morphological types with an outer ring structure and ultraviolet emission from the ring. These characteristic are determined for the outer ring structures and for the galaxies as a whole. Data from the space telescopes GALEX (in the NUV and FUV ultraviolet ranges) and WISE (in the W4 22 μm infrared band) are used. The average relative deviation in the corrected SFR and ΣSFR derived from the NUV and FUV bands is only 19.0%, so their averaged values are used for statistical consideration. The relations between the dust-corrected SFR characteristics, UV colours, the galaxy morphological type, absolute magnitude are illustrated.

  14. Density of Jatropha curcas Seed Oil and its Methyl Esters: Measurement and Estimations

    NASA Astrophysics Data System (ADS)

    Veny, Harumi; Baroutian, Saeid; Aroua, Mohamed Kheireddine; Hasan, Masitah; Raman, Abdul Aziz; Sulaiman, Nik Meriam Nik

    2009-04-01

    Density data as a function of temperature have been measured for Jatropha curcas seed oil, as well as biodiesel jatropha methyl esters at temperatures from above their melting points to 90 ° C. The data obtained were used to validate the method proposed by Spencer and Danner using a modified Rackett equation. The experimental and estimated density values using the modified Rackett equation gave almost identical values with average absolute percent deviations less than 0.03% for the jatropha oil and 0.04% for the jatropha methyl esters. The Janarthanan empirical equation was also employed to predict jatropha biodiesel densities. This equation performed equally well with average absolute percent deviations within 0.05%. Two simple linear equations for densities of jatropha oil and its methyl esters are also proposed in this study.

  15. A standardized model for predicting flap failure using indocyanine green dye

    NASA Astrophysics Data System (ADS)

    Zimmermann, Terence M.; Moore, Lindsay S.; Warram, Jason M.; Greene, Benjamin J.; Nakhmani, Arie; Korb, Melissa L.; Rosenthal, Eben L.

    2016-03-01

    Techniques that provide a non-invasive method for evaluation of intraoperative skin flap perfusion are currently available but underutilized. We hypothesize that intraoperative vascular imaging can be used to reliably assess skin flap perfusion and elucidate areas of future necrosis by means of a standardized critical perfusion threshold. Five animal groups (negative controls, n=4; positive controls, n=5; chemotherapy group, n=5; radiation group, n=5; chemoradiation group, n=5) underwent pre-flap treatments two weeks prior to undergoing random pattern dorsal fasciocutaneous flaps with a length to width ratio of 2:1 (3 x 1.5 cm). Flap perfusion was assessed via laser-assisted indocyanine green dye angiography and compared to standard clinical assessment for predictive accuracy of flap necrosis. For estimating flap-failure, clinical prediction achieved a sensitivity of 79.3% and a specificity of 90.5%. When average flap perfusion was more than three standard deviations below the average flap perfusion for the negative control group at the time of the flap procedure (144.3+/-17.05 absolute perfusion units), laser-assisted indocyanine green dye angiography achieved a sensitivity of 81.1% and a specificity of 97.3%. When absolute perfusion units were seven standard deviations below the average flap perfusion for the negative control group, specificity of necrosis prediction was 100%. Quantitative absolute perfusion units can improve specificity for intraoperative prediction of viable tissue. Using this strategy, a positive predictive threshold of flap failure can be standardized for clinical use.

  16. SU-F-T-227: A Comprehensive Patient Specific, Structure Specific, Pre-Treatment 3D QA Protocol for IMRT, SBRT and VMAT - Clinical Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gueorguiev, G; Cotter, C; Young, M

    2016-06-15

    Purpose: To present a 3D QA method and clinical results for 550 patients. Methods: Five hundred and fifty patient treatment deliveries (400 IMRT, 75 SBRT and 75 VMAT) from various treatment sites, planned on Raystation treatment planning system (TPS), were measured on three beam-matched Elekta linear accelerators using IBA’s COMPASS system. The difference between TPS computed and delivered dose was evaluated in 3D by applying three statistical parameters to each structure of interest: absolute average dose difference (AADD, 6% allowed difference), absolute dose difference greater than 6% (ADD6, 4% structure volume allowed to fail) and 3D gamma test (3%/3mm DTA,more » 4% structure volume allowed to fail). If the allowed value was not met for a given structure, manual review was performed. The review consisted of overlaying dose difference or gamma results with the patient CT, scrolling through the slices. For QA to pass, areas of high dose difference or gamma must be small and not on consecutive slices. For AADD to manually pass QA, the average dose difference in cGy must be less than 50cGy. The QA protocol also includes DVH analysis based on QUANTEC and TG-101 recommended dose constraints. Results: Figures 1–3 show the results for the three parameters per treatment modality. Manual review was performed on 67 deliveries (27 IMRT, 22 SBRT and 18 VMAT), for which all passed QA. Results show that statistical parameter AADD may be overly sensitive for structures receiving low dose, especially for the SBRT deliveries (Fig.1). The TPS computed and measured DVH values were in excellent agreement and with minimum difference. Conclusion: Applying DVH analysis and different statistical parameters to any structure of interest, as part of the 3D QA protocol, provides a comprehensive treatment plan evaluation. Author G. Gueorguiev discloses receiving travel and research funding from IBA for unrelated to this project work. Author B. Crawford discloses receiving travel funding from IBA for unrelated to this project work.« less

  17. Arima model and exponential smoothing method: A comparison

    NASA Astrophysics Data System (ADS)

    Wan Ahmad, Wan Kamarul Ariffin; Ahmad, Sabri

    2013-04-01

    This study shows the comparison between Autoregressive Moving Average (ARIMA) model and Exponential Smoothing Method in making a prediction. The comparison is focused on the ability of both methods in making the forecasts with the different number of data sources and the different length of forecasting period. For this purpose, the data from The Price of Crude Palm Oil (RM/tonne), Exchange Rates of Ringgit Malaysia (RM) in comparison to Great Britain Pound (GBP) and also The Price of SMR 20 Rubber Type (cents/kg) with three different time series are used in the comparison process. Then, forecasting accuracy of each model is measured by examinethe prediction error that producedby using Mean Squared Error (MSE), Mean Absolute Percentage Error (MAPE), and Mean Absolute deviation (MAD). The study shows that the ARIMA model can produce a better prediction for the long-term forecasting with limited data sources, butcannot produce a better prediction for time series with a narrow range of one point to another as in the time series for Exchange Rates. On the contrary, Exponential Smoothing Method can produce a better forecasting for Exchange Rates that has a narrow range of one point to another for its time series, while itcannot produce a better prediction for a longer forecasting period.

  18. Wearable Vector Electrical Bioimpedance System to Assess Knee Joint Health

    PubMed Central

    Hersek, Sinan; Töreyin, Hakan; Teague, Caitlin N.; Millard-Stafford, Mindy L.; Jeong, Hyeon-Ki; Bavare, Miheer M.; Wolkoff, Paul; Sawka, Michael N.; Inan, Omer T.

    2017-01-01

    Objective We designed and validated a portable electrical bioimpedance (EBI) system to quantify knee joint health. Methods Five separate experiments were performed to demonstrate the: (1) ability of the EBI system to assess knee injury and recovery; (2) inter-day variability of knee EBI measurements; (3) sensitivity of the system to small changes in interstitial fluid volume; (4) reducing the error of EBI measurements using acceleration signals; (5) use of the system with dry electrodes integrated to a wearable knee wrap. Results (1) The absolute difference in resistance (R) and reactance (X) from the left to the right knee was able to distinguish injured and healthy knees (p<0.05); the absolute difference in R decreased significantly (p<0.05) in injured subjects following rehabilitation. (2) The average inter-day variability (standard deviation) of the absolute difference in knee R was 2.5Ω, and for X was, 1.2 Ω. (3) Local heating/cooling resulted in a significant decrease/increase in knee R (p<0.01). (4) The proposed subject position detection algorithm achieved 97.4% leave-one subject out cross-validated accuracy and 98.2% precision in detecting when the subject is in the correct position to take measurements. (5) Linear regression between the knee R and X measured using the wet electrodes and the designed wearable knee wrap were highly correlated (r2 = 0.8 and 0.9, respectively). Conclusion This work demonstrates the use of wearable EBI measurements in monitoring knee joint health. Significance The proposed wearable system has the potential for assessing knee joint health outside the clinic/lab and help guide rehabilitation. PMID:28026745

  19. Wearable Vector Electrical Bioimpedance System to Assess Knee Joint Health.

    PubMed

    Hersek, Sinan; Toreyin, Hakan; Teague, Caitlin N; Millard-Stafford, Mindy L; Jeong, Hyeon-Ki; Bavare, Miheer M; Wolkoff, Paul; Sawka, Michael N; Inan, Omer T

    2017-10-01

    We designed and validated a portable electrical bioimpedance (EBI) system to quantify knee joint health. Five separate experiments were performed to demonstrate the: 1) ability of the EBI system to assess knee injury and recovery; 2) interday variability of knee EBI measurements; 3) sensitivity of the system to small changes in interstitial fluid volume; 4) reducing the error of EBI measurements using acceleration signals; and 5) use of the system with dry electrodes integrated to a wearable knee wrap. 1) The absolute difference in resistance ( R) and reactance (X) from the left to the right knee was able to distinguish injured and healthy knees (p < 0.05); the absolute difference in R decreased significantly (p < 0.05) in injured subjects following rehabilitation. 2) The average interday variability (standard deviation) of the absolute difference in knee R was 2.5 Ω and for X was 1.2 Ω. 3) Local heating/cooling resulted in a significant decrease/increase in knee R (p < 0.01). 4) The proposed subject position detection algorithm achieved 97.4% leave-one subject out cross-validated accuracy and 98.2% precision in detecting when the subject is in the correct position to take measurements. 5) Linear regression between the knee R and X measured using the wet electrodes and the designed wearable knee wrap were highly correlated ( R 2 = 0.8 and 0.9, respectively). This study demonstrates the use of wearable EBI measurements in monitoring knee joint health. The proposed wearable system has the potential for assessing knee joint health outside the clinic/lab and help guide rehabilitation.

  20. Effects of benefits and harms on older persons' willingness to take medication for primary cardiovascular prevention.

    PubMed

    Fried, Terri R; Tinetti, Mary E; Towle, Virginia; O'Leary, John R; Iannone, Lynne

    2011-05-23

    Quality-assurance initiatives encourage adherence to evidenced-based guidelines based on a consideration of treatment benefit. We examined older persons' willingness to take medication for primary cardiovascular disease prevention according to benefits and harms. In-person interviews were performed with 356 community-living older persons. Participants were asked about their willingness to take medication for primary prevention of myocardial infarction (MI) with varying benefits in terms of absolute 5-year risk reduction and varying harms in terms of type and severity of adverse effects. Most (88%) would take medication, providing an absolute benefit of 6 fewer persons with MI out of 100, approximating the average risk reduction of currently available medications. Of participants who would not take it, 17% changed their preference if the absolute benefit was increased to 10 fewer persons with MI, and, of participants who would take it, 82% remained willing if the absolute benefit was decreased to 3 fewer persons with MI. In contrast, large proportions (48%-69%) were unwilling or uncertain about taking medication with average benefit causing mild fatigue, nausea, or fuzzy thinking, and only 3% would take medication with adverse effects severe enough to affect functioning. Older persons' willingness to take medication for primary cardiovascular disease prevention is relatively insensitive to its benefit but highly sensitive to its adverse effects. These results suggest that clinical guidelines and decisions about prescribing these medications to older persons need to place emphasis on both benefits and harms.

  1. Risk and treatment effect heterogeneity: re-analysis of individual participant data from 32 large clinical trials

    PubMed Central

    Kent, David M; Nelson, Jason; Dahabreh, Issa J; Rothwell, Peter M; Altman, Douglas G; Hayward, Rodney A

    2016-01-01

    Abstract Background: Risk of the outcome is a mathematical determinant of the absolute treatment benefit of an intervention, yet this can vary substantially within a trial population, complicating the interpretation of trial results. Methods: We developed risk models using Cox or logistic regression on a set of large publicly available randomized controlled trials (RCTs). We evaluated risk heterogeneity using the extreme quartile risk ratio (EQRR, the ratio of outcome rates in the lowest risk quartile to that in the highest) and skewness using the median to mean risk ratio (MMRR, the ratio of risk in the median risk patient to the average). We also examined heterogeneity of treatment effects (HTE) across risk strata. Results: We describe 39 analyses using data from 32 large trials, with event rates across studies ranging from 3% to 63% (median = 15%, 25th–75th percentile = 9–29%). C-statistics of risk models ranged from 0.59 to 0.89 (median = 0.70, 25th–75th percentile = 0.65–0.71). The EQRR ranged from 1.8 to 50.7 (median = 4.3, 25th–75th percentile = 3.0–6.1). The MMRR ranged from 0.4 to 1.0 (median = 0.86, 25th–75th percentile = 0.80–0.92). EQRRs were predictably higher and MMRRs predictably lower as the c-statistic increased or the overall outcome incidence decreased. Among 18 comparisons with a significant overall treatment effect, there was a significant interaction between treatment and baseline risk on the proportional scale in only one. The difference in the absolute risk reduction between extreme risk quartiles ranged from −3.2 to 28.3% (median = 5.1%; 25th–75th percentile = 0.3–10.9). Conclusions: There is typically substantial variation in outcome risk in clinical trials, commonly leading to clinically significant differences in absolute treatment effects. Most patients have outcome risks lower than the trial average reflected in the summary result. Risk-stratified trial analyses are feasible and may be clinically informative, particularly when the outcome is predictable and uncommon. PMID:27375287

  2. Prevalence of absolute pitch: a comparison between Japanese and Polish music students.

    PubMed

    Miyazaki, Ken'ichi; Makomaska, Sylwia; Rakowski, Andrzej

    2012-11-01

    Comparable large-scale surveys including an on-site pitch-naming test were conducted with music students in Japan and Poland to obtain more convincing estimates of the prevalence of absolute pitch (AP) and examine how musical experience relates to AP. Participants with accurate AP (95% correct identification) accounted for 30% of the Japanese music students, but only 7% of the Polish music students. This difference in the performance of pitch naming was related to the difference in musical experience. Participants with AP had begun music training at an earlier age (6 years or earlier), and the average year of commencement of musical training was more than 2 years earlier for the Japanese music students than for the Polish students. The percentage of participants who had received early piano lessons was 94% for the Japanese musically trained students but was 72% for the Polish music students. Approximately one-third of the Japanese musically trained students had attended the Yamaha Music School, where lessons on piano or electric organ were given to preschool children in parallel with fixed-do solfège singing training. Such early music instruction was not as common in Poland. The relationship of AP with early music training is discussed.

  3. Low-flow analysis and selected flow statistics representative of 1930-2002 for streamflow-gaging stations in or near West Virginia

    USGS Publications Warehouse

    Wiley, Jeffrey B.

    2006-01-01

    Five time periods between 1930 and 2002 are identified as having distinct patterns of annual minimum daily mean flows (minimum flows). Average minimum flows increased around 1970 at many streamflow-gaging stations in West Virginia. Before 1930, however, there might have been a period of minimum flows greater than any period identified between 1930 and 2002. The effects of climate variability are probably the principal causes of the differences among the five time periods. Comparisons of selected streamflow statistics are made between values computed for the five identified time periods and values computed for the 1930-2002 interval for 15 streamflow-gaging stations. The average difference between statistics computed for the five time periods and the 1930-2002 interval decreases with increasing magnitude of the low-flow statistic. The greatest individual-station absolute difference was 582.5 percent greater for the 7-day 10-year low flow computed for 1970-1979 compared to the value computed for 1930-2002. The hydrologically based low flows indicate approximately equal or smaller absolute differences than biologically based low flows. The average 1-day 3-year biologically based low flow (1B3) and 4-day 3-year biologically based low flow (4B3) are less than the average 1-day 10-year hydrologically based low flow (1Q10) and 7-day 10-year hydrologic-based low flow (7Q10) respectively, and range between 28.5 percent less and 13.6 percent greater. Seasonally, the average difference between low-flow statistics computed for the five time periods and 1930-2002 is not consistent between magnitudes of low-flow statistics, and the greatest difference is for the summer (July 1-September 30) and fall (October 1-December 31) for the same time period as the greatest difference determined in the annual analysis. The greatest average difference between 1B3 and 4B3 compared to 1Q10 and 7Q10, respectively, is in the spring (April 1-June 30), ranging between 11.6 and 102.3 percent greater. Statistics computed for the individual station's record period may not represent the statistics computed for the period 1930 to 2002 because (1) station records are available predominantly after about 1970 when minimum flows were greater than the average between 1930 and 2002 and (2) some short-term station records are mostly during dry periods, whereas others are mostly during wet periods. A criterion-based sampling of the individual station's record periods at stations was taken to reduce the effects of statistics computed for the entire record periods not representing the statistics computed for 1930-2002. The criterion used to sample the entire record periods is based on a comparison between the regional minimum flows and the minimum flows at the stations. Criterion-based sampling of the available record periods was superior to record-extension techniques for this study because more stations were selected and areal distribution of stations was more widespread. Principal component and correlation analyses of the minimum flows at 20 stations in or near West Virginia identify three regions of the State encompassing stations with similar patterns of minimum flows: the Lower Appalachian Plateaus, the Upper Appalachian Plateaus, and the Eastern Panhandle. All record periods of 10 years or greater between 1930 and 2002 where the average of the regional minimum flows are nearly equal to the average for 1930-2002 are determined as representative of 1930-2002. Selected statistics are presented for the longest representative record period that matches the record period for 77 stations in West Virginia and 40 stations near West Virginia. These statistics can be used to develop equations for estimating flow in ungaged stream locations.

  4. Assessing agreement between malaria slide density readings.

    PubMed

    Alexander, Neal; Schellenberg, David; Ngasala, Billy; Petzold, Max; Drakeley, Chris; Sutherland, Colin

    2010-01-04

    Several criteria have been used to assess agreement between replicate slide readings of malaria parasite density. Such criteria may be based on percent difference, or absolute difference, or a combination. Neither the rationale for choosing between these types of criteria, nor that for choosing the magnitude of difference which defines acceptable agreement, are clear. The current paper seeks a procedure which avoids the disadvantages of these current options and whose parameter values are more clearly justified. Variation of parasite density within a slide is expected, even when it has been prepared from a homogeneous sample. This places lower limits on sensitivity and observer agreement, quantified by the Poisson distribution. This means that, if a criterion of fixed percent difference criterion is used for satisfactory agreement, the number of discrepant readings is over-estimated at low parasite densities. With a criterion of fixed absolute difference, the same happens at high parasite densities. For an ideal slide, following the Poisson distribution, a criterion based on a constant difference in square root counts would apply for all densities. This can be back-transformed to a difference in absolute counts, which, as expected, gives a wider range of acceptable agreement at higher average densities. In an example dataset from Tanzania, observed differences in square root counts correspond to a 95% limits of agreement of -2,800 and +2,500 parasites/microl at average density of 2,000 parasites/microl, and -6,200 and +5,700 parasites/microl at 10,000 parasites/microl. However, there were more outliers beyond those ranges at higher densities, meaning that actual coverage of these ranges was not a constant 95%, but decreased with density. In a second study, a trial of microscopist training, the corresponding ranges of agreement are wider and asymmetrical: -8,600 to +5,200/microl, and -19,200 to +11,700/microl, respectively. By comparison, the optimal limits of agreement, corresponding to Poisson variation, are +/- 780 and +/- 1,800 parasites/microl, respectively. The focus of this approach on the volume of blood read leads to other conclusions. For example, no matter how large a volume of blood is read, some densities are too low to be reliably detected, which in turn means that disagreements on slide positivity may simply result from within-slide variation, rather than reading errors. The proposed method defines limits of acceptable agreement in a way which allows for the natural increase in variability with parasite density. This includes defining the levels of between-reader variability, which are consistent with random variation: disagreements within these limits should not trigger additional readings. This approach merits investigation in other settings, in order to determine both the extent of its applicability, and appropriate numerical values for limits of agreement.

  5. Statistical Analysis on the Performance of Molecular Mechanics Poisson-Boltzmann Surface Area versus Absolute Binding Free Energy Calculations: Bromodomains as a Case Study.

    PubMed

    Aldeghi, Matteo; Bodkin, Michael J; Knapp, Stefan; Biggin, Philip C

    2017-09-25

    Binding free energy calculations that make use of alchemical pathways are becoming increasingly feasible thanks to advances in hardware and algorithms. Although relative binding free energy (RBFE) calculations are starting to find widespread use, absolute binding free energy (ABFE) calculations are still being explored mainly in academic settings due to the high computational requirements and still uncertain predictive value. However, in some drug design scenarios, RBFE calculations are not applicable and ABFE calculations could provide an alternative. Computationally cheaper end-point calculations in implicit solvent, such as molecular mechanics Poisson-Boltzmann surface area (MMPBSA) calculations, could too be used if one is primarily interested in a relative ranking of affinities. Here, we compare MMPBSA calculations to previously performed absolute alchemical free energy calculations in their ability to correlate with experimental binding free energies for three sets of bromodomain-inhibitor pairs. Different MMPBSA approaches have been considered, including a standard single-trajectory protocol, a protocol that includes a binding entropy estimate, and protocols that take into account the ligand hydration shell. Despite the improvements observed with the latter two MMPBSA approaches, ABFE calculations were found to be overall superior in obtaining correlation with experimental affinities for the test cases considered. A difference in weighted average Pearson ([Formula: see text]) and Spearman ([Formula: see text]) correlations of 0.25 and 0.31 was observed when using a standard single-trajectory MMPBSA setup ([Formula: see text] = 0.64 and [Formula: see text] = 0.66 for ABFE; [Formula: see text] = 0.39 and [Formula: see text] = 0.35 for MMPBSA). The best performing MMPBSA protocols returned weighted average Pearson and Spearman correlations that were about 0.1 inferior to ABFE calculations: [Formula: see text] = 0.55 and [Formula: see text] = 0.56 when including an entropy estimate, and [Formula: see text] = 0.53 and [Formula: see text] = 0.55 when including explicit water molecules. Overall, the study suggests that ABFE calculations are indeed the more accurate approach, yet there is also value in MMPBSA calculations considering the lower compute requirements, and if agreement to experimental affinities in absolute terms is not of interest. Moreover, for the specific protein-ligand systems considered in this study, we find that including an explicit ligand hydration shell or a binding entropy estimate in the MMPBSA calculations resulted in significant performance improvements at a negligible computational cost.

  6. Absolute x-ray dosimetry on a synchrotron medical beam line with a graphite calorimeter.

    PubMed

    Harty, P D; Lye, J E; Ramanathan, G; Butler, D J; Hall, C J; Stevenson, A W; Johnston, P N

    2014-05-01

    The absolute dose rate of the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter. The calorimetry results were compared to measurements from the existing free-air chamber, to provide a robust determination of the absolute dose in the synchrotron beam and provide confidence in the first implementation of a graphite calorimeter on a synchrotron medical beam line. The graphite calorimeter has a core which rises in temperature when irradiated by the beam. A collimated x-ray beam from the synchrotron with well-defined edges was used to partially irradiate the core. Two filtration sets were used, one corresponding to an average beam energy of about 80 keV, with dose rate about 50 Gy/s, and the second filtration set corresponding to average beam energy of 90 keV, with dose rate about 20 Gy/s. The temperature rise from this beam was measured by a calibrated thermistor embedded in the core which was then converted to absorbed dose to graphite by multiplying the rise in temperature by the specific heat capacity for graphite and the ratio of cross-sectional areas of the core and beam. Conversion of the measured absorbed dose to graphite to absorbed dose to water was achieved using Monte Carlo calculations with the EGSnrc code. The air kerma measurements from the free-air chamber were converted to absorbed dose to water using the AAPM TG-61 protocol. Absolute measurements of the IMBL dose rate were made using the graphite calorimeter and compared to measurements with the free-air chamber. The measurements were at three different depths in graphite and two different filtrations. The calorimetry measurements at depths in graphite show agreement within 1% with free-air chamber measurements, when converted to absorbed dose to water. The calorimetry at the surface and free-air chamber results show agreement of order 3% when converted to absorbed dose to water. The combined standard uncertainty is 3.9%. The good agreement of the graphite calorimeter and free-air chamber results indicates that both devices are performing as expected. Further investigations at higher dose rates than 50 Gy/s are planned. At higher dose rates, recombination effects for the free-air chamber are much higher and expected to lead to much larger uncertainties. Since the graphite calorimeter does not have problems associated with dose rate, it is an appropriate primary standard detector for the synchrotron IMBL x rays and is the more accurate dosimeter for the higher dose rates expected in radiotherapy applications.

  7. Geographic health inequalities in Norway: a Gini analysis of cross-county differences in mortality from 1980 to 2014.

    PubMed

    Skaftun, Eirin K; Verguet, Stéphane; Norheim, Ole F; Johansson, Kjell A

    2018-05-24

    This study aims at quantifying the level and changes over time of inequality in age-specific mortality and life expectancy between the 19 Norwegian counties from 1980 to 2014. Data on population and mortality by county was obtained from Statistics Norway for 1980-2014. Life expectancy and age-specific mortality rates (0-4, 5-49 and 50-69 age groups) were estimated by year and county. Geographic inequality was described by the absolute Gini index annually. Life expectancy in Norway has increased from 75.6 to 82.0 years, and the risk of death before the age of 70 has decreased from 26 to 14% from 1980 to 2014. The absolute Gini index decreased over the period 1980 to 2014 from 0.43 to 0.32 for life expectancy, from 0.012 to 0.0057 for the age group 50-69 years, from 0.0038 to 0.0022 for the age group 5-49 years, and from 0.0009 to 0.0006 for the age group 0-4 years. It will take between 2 and 32 years (national average 7 years) until the counties catch up with the life expectancy in the best performing county if their annual rates of increase remain unchanged. Using the absolute Gini index as a metric for monitoring changes in geographic inequality over time may be a valuable tool for informing public health policies. The absolute inequality in mortality and life expectancy between Norwegian counties has decreased from 1980 to 2014.

  8. A digital simulation of the glacial-aquifer system in the northern three-fourths of Brown County, South Dakota

    USGS Publications Warehouse

    Emmons, P.J.

    1990-01-01

    A digital model was developed to simulate groundwater flow in a complex glacial-aquifer system that includes the Elm, Middle James, and Deep James aquifers in South Dakota. The average thickness of the aquifers ranges from 16 to 32 ft and the average hydraulic conductivity ranges from 240 to 300 ft/day. The maximum steady-state recharge to the aquifer system was estimated to be 7.0 in./yr, and the maximum potential steady- state evapotranspiration was estimated to be 35.4 in/yr. Maximum monthly recharge for 1985 ranged from zero in the winter to 2.5 in in May. The potential monthly evapotranspiration for 1985 ranged from zero in the winter to 7.0 in in July. The average difference between the simulated and observed water levels from steady-state conditions (pre-1983) was 0. 78 ft and the average absolute difference was 4.59 ft for aquifer layer 1 (the Elm aquifer) from 22 observation wells and 3.49 ft and 5.10 ft, respectively, for aquifer layer 2 (the Middle James aquifer) from 13 observation wells. The average difference between the simulated and observed water levels from simulated monthly potentiometric heads for 1985 in aquifer layer 1 ranged from -2.54 ft in July to 0.59 ft in May and in aquifer layer 2 ranged from -1.22 ft in April to 4.98 ft in November. Sensitivity analysis of the steady-state model indicates that it is most sensitive to changes in recharge and least sensitive to changes in hydraulic conductivity. (USGS)

  9. Observations and analysis of lunar radio emission at 3.09 mm wavelength

    NASA Technical Reports Server (NTRS)

    Ulich, B. L.; Cogdell, J. R.; Davis, J. H.; Calvert, T. A.

    1974-01-01

    An analysis of data on lunar radio emission at 3.09 mm wavelength is presented. The data were obtained during a single lunation in a manner that facilitates their comparison with a calculated model. Specific regions of the moon (Copernicus, Sea of Serenity, Sea of Tranquillity, Ocean of Storms, and an highland region near the mean center) were studied with enough angular resolution to distinguish between different types of terrain. The data were absolutely calibrated and yield a new measurement of the lunation average brightness temperature of the center of the moon.

  10. Estimated metabolic and mechanical demands during different small-sided games in elite soccer players.

    PubMed

    Gaudino, Paolo; Alberti, Giampietro; Iaia, F Marcello

    2014-08-01

    The present study examined the extent to which game format (possession play, SSG-P and game with regular goals and goalkeepers, SSG-G) and the number of players (5, 7 and 10 a-side) influence the physical demands of small-sided soccer games (SSGs) in elite soccer players. Training data were collected during the in-season period from 26 English Premier League outfield players using global positioning system technology. Total distance covered, distance at different speed categories and maximal speed were calculated. In addition, we focused on changes in velocity by reporting the number of accelerations and decelerations carried out during the SSGs (divided in two categories: moderate and high) and the absolute maximal values of acceleration and deceleration achieved. By taking into account these parameters besides speed and distance values, estimated energy expenditure and average metabolic power and distance covered at different metabolic power categories were calculated. All variables were normalized by time (i.e., 4min). The main findings were that the total distance, distances run at high speed (>14.4kmh(-1)) as well as absolute maximum velocity, maximum acceleration and maximum deceleration increased with pitch size (10v10>7v7>5v5; p<.05). Furthermore, total distance, very high (19.8-25.2kmh(-1)) and maximal (>25.2kmh(-1)) speed distances, absolute maximal velocity and maximum acceleration and deceleration were higher in SSG-G than in SSG-P (p<.001). On the other hand, the number of moderate (2-3ms(-2)) accelerations and decelerations as well as the total number of changes in velocity were greater as the pitch dimensions decreased (i.e., 5v5>7v7>10v10; p<.001) in both SSG-G and SSG-P. In addition, predicted energy cost, average metabolic power and distance covered at every metabolic power categories were higher in SSG-P compared to SSG-G and in big than in small pitch areas (p<.05). A detailed analysis of these drills is pivotal in contemporary football as it enables an in depth understanding of the workload imposed on each player which consequently has practical implications for the prescription of the adequate type and amount of stimulus during exercise training. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. [Influence of the duration of recording in the reproducibility of the signal averaged electrocardiogram].

    PubMed

    Copie, X; Blankoff, I; Hnatkova, K; Fei, L; Camm, A J; Malik, M

    1996-06-01

    The authors studied the possibility of improving the reproducibility of the signal averaged ECG by increasing the number of averaged QRS complexes. One hundred patients were included in the study. In each cases, 400 QRS complexes were recorded on twice, consecutively, in strictly identical conditions. During each recording, the total duration of the amplified and averaged QRS complex (tQRS), the duration of the terminal signal below 40 microV (LAS) and the root mean square of the amplitude of the last 40 ms (RMS) were determined for 100, 200, 300 and 400 recorded QRS complexes. The presence of late potentials was defined as the positivity of two of the following criteria: tQRS > 114 ms, LAS > 38 ms, RMS < 20 microV. The number of contradictory diagnostic conclusions between two successive recordings of the same duration decreased progressively with the number of averaged QRS complexes: 10 for 100 QRS, 10 for 200 QRS, 9 for 300 QRS and 6 for 400 QRS complexes, but this improvement was not statistically significant. The absolute differences of tQRS and RMS between two successive recordings of the same duration were statistically different for the four durations of recording (p = 0.05) and there was a tendency towards statistical significance for LAS (p = 0.09). The best quantitative reproducibility of the 3 parameters was obtained with the recording of 300 QRS complexes. In conclusion, the reproducibility of the signal averaged ECG is improved when the number of average QRS complexes is increased. The authors' results suggests that reproducibility this is optimal with the amplification and averaging of 300 QRS complexes.

  12. Sex-related differences in foot shape.

    PubMed

    Krauss, I; Grau, S; Mauch, M; Maiwald, C; Horstmann, T

    2008-11-01

    The purpose of the study was to investigate sex-related differences in foot morphology. In total, 847 subjects were scanned using a 3-D-footscanner. Three different analysis methods were used: (1) comparisons were made for absolute foot measures within 250-270 mm foot length (FL); (2) and for averaged measures (% FL) across all sizes; (3) the feet were then classified using a cluster analysis. Within 250-270 mm FL, male feet were wider and higher (mean differences (MD) 1.3-5.9 mm). No relevant sex-related differences could be found in the comparison of averaged measures (MD 0.3-0.6% FL). Foot types were categorised into voluminous, flat-pointed and slender. Shorter feet were more often voluminous, longer feet were more likely to be narrow and flat. However, the definition of 'short' and 'long' was sex-related; thus, allometry of foot measures was different. For shoe design, measures should be derived for each size and sex separately. Different foot types should be considered to account for the variety in foot shape. Improper footwear can cause foot pain and deformity. Therefore, knowledge of sex-related differences in foot measures is important to assist proper shoe fit in both men and women. The present study supplements the field of knowledge within this context with recommendations for the manufacturing of shoes.

  13. Communicating cardiovascular disease risk: an interview study of General Practitioners' use of absolute risk within tailored communication strategies.

    PubMed

    Bonner, Carissa; Jansen, Jesse; McKinn, Shannon; Irwig, Les; Doust, Jenny; Glasziou, Paul; McCaffery, Kirsten

    2014-05-29

    Cardiovascular disease (CVD) prevention guidelines encourage assessment of absolute CVD risk - the probability of a CVD event within a fixed time period, based on the most predictive risk factors. However, few General Practitioners (GPs) use absolute CVD risk consistently, and communication difficulties have been identified as a barrier to changing practice. This study aimed to explore GPs' descriptions of their CVD risk communication strategies, including the role of absolute risk. Semi-structured interviews were conducted with a purposive sample of 25 GPs in New South Wales, Australia. Transcribed audio-recordings were thematically coded, using the Framework Analysis method to ensure rigour. GPs used absolute CVD risk within three different communication strategies: 'positive', 'scare tactic', and 'indirect'. A 'positive' strategy, which aimed to reassure and motivate, was used for patients with low risk, determination to change lifestyle, and some concern about CVD risk. Absolute risk was used to show how they could reduce risk. A 'scare tactic' strategy was used for patients with high risk, lack of motivation, and a dismissive attitude. Absolute risk was used to 'scare' them into taking action. An 'indirect' strategy, where CVD risk was not the main focus, was used for patients with low risk but some lifestyle risk factors, high anxiety, high resistance to change, or difficulty understanding probabilities. Non-quantitative absolute risk formats were found to be helpful in these situations. This study demonstrated how GPs use three different communication strategies to address the issue of CVD risk, depending on their perception of patient risk, motivation and anxiety. Absolute risk played a different role within each strategy. Providing GPs with alternative ways of explaining absolute risk, in order to achieve different communication aims, may improve their use of absolute CVD risk assessment in practice.

  14. Comparing SUV values of images at PET-CT console and the RT planning console using identical dataset of a study phantom.

    PubMed

    Munshi, Anusheel; Paul, Sayan; Sarkar, Biplab; Bala, Pinkey; Ganesh, Tharmar; Sen, Ishita B; Pant, Vineet; Mohanti, Bidhu K

    2016-01-01

    The use of positron emission tomography (PET) for radiotherapy planning purposes has become increasingly important in the last few years.In the current study, we compared the SUV values of images at the PET CT console to the SUV values obtained at the RT planning workstation. The PET-CT cylindrical body phantom was filled with a uniform 18F solution of 5.3. ± 0.27 kBq/mL radioactivity concentration. PET-CT scans were performed on a16 slice Time of Flight system. On a single day, the three consecutive scans were done at three time points 15 minutes apart to generate time points image data sets titled T1, T2, and T3. SUV calculations were performed by drawing region of interest. (ROI) encompassing the entire hot spot on each slice on the PET-CT console and the iPlan workstation. Minimum SUV, Maximum SUV and the Mean SUV were recorded. Statistical analysis was done using the SPSS software. (SPSS Inc.) (Version 18). The absolute difference in average max SUV values i.e. Max (PET-CT) - Max (iPlan) for the time points T1, T2 and T3 were -0.168 (SD 0.175), -0.172 (SD 0.172) and -0.178 (SD 0.169). The difference in the minimum SUV values were -0.513 (SD 0.428), -0.311 (SD 0.358) and -0.303 (SD 0.322), respectively. Finally, the difference in the mean SUV values were -0.107 (SD 0.040), -0.096 (SD 0.067) and -0.072 (SD 0.044), respectively. Our study found out that the average difference in the two systems for maximum SUV values was < 0.2 absolute units.Our study suggests good reproducibility of SUV between the two systems. The relevance of these findings would be of seminal importance in current and future SUV-based PET-CT-based contouring in treatment planning systems.

  15. A comparison of speech outcomes using radical intravelar veloplasty or furlow palatoplasty for the treatment of velopharyngeal insufficiency associated with occult submucous cleft palate.

    PubMed

    Afrooz, Paul Nader; MacIsaac, Zoe; Rottgers, Stephen Alex; Ford, Matthew; Grunwaldt, Lorelei J; Kumar, Anand R

    2015-02-01

    The safety, efficacy, and direct comparison of various surgical treatments for velopharyngeal insufficiency (VPI) associated with occult submucous cleft palate (OSMCP) are poorly characterized. The aim of this study was to report and analyze the safety and efficacy of Furlow palatoplasty (FP) versus radical intravelar veloplasty (IVV) for treatment of VPI associated with OSMCP. A retrospective review of one institution's experience treating VPI associated with OSMCP using IVV (group 1) or FP (group 2) during 24 months was performed. Statistical significance was determined by Wilcoxon matched-pair, Independent-Samples Mann-Whitney U, and analysis of variance (SPSS 20.0.0). In group 1 (IVV), 18 patients were identified from August 2010 to 2011 (12 male and 6 female patients; average age, 5.39 years). Seven patients were syndromic and 11 were nonsyndromic. In group 2 (FP), 17 patients were identified from August 2009 to 2011 (8 male and 9 female patients; average age, 8.37 years). Three patients were syndromic and 14 patients were nonsyndromic. There was statistical significance between the average pretreatment Pittsburgh Weighted Speech Score (PWSS) of the 2 groups (group 1 and 2 averages 19.06 and 11.05, respectively, P=0.002), but there was no statistical significance postoperatively (group 1 and 2 averages 4.50 and 4.69, respectively, P=0.405). One patient from each group required secondary speech surgery. Average operative time was greater for FP (140 minutes; range, 93-177 minutes) compared to IVV (95 minutes; range, 58-135 minutes), P<0.001. Average hospital stay was 3.9 days for IVV (range, 2-9 days) and 3.2 days for FP (range, 2-6 days), with no significant difference (P=0.116). There were no postsurgical wound infections, oral-nasal fistulas, postoperative bleeding complications, or mortalities. Nonsyndromic patients with hypernasal speech are treated effectively and safely with either IVV or FP. Intravelar veloplasty trended toward lower speech scores than FP (76% IVV, 58% FP PWSS absolute reduction). Syndromic patients with OSMCP may be more effectively treated with FP (72% IVV vs 79% FP PWSS absolute reduction). Intravelar veloplasty is associated with shorter operative times. Both techniques are associated with low morbidity, improved speech scores, and low reoperative rates.

  16. Analysis of sewage sludge using an experimental prompt gamma neutron activation analysis (pgnaa) set-up with an am-be source

    NASA Astrophysics Data System (ADS)

    Idiri, Z.; Redjem, F.; Beloudah, N.

    2016-09-01

    An experimental PGNAA set-up using a 1 Ci Am-Be source has been developed and used for analysis of bulk sewage sludge samples issued from a wastewater treatment plant situated in an industrial area of Algiers. The sample dimensions were optimized using thermal neutron flux calculations carried out with the MCNP5 Monte Carlo Code. A methodology is then proposed to perform quantitative analysis using the absolute method. For this, average thermal neutron flux inside the sludge samples is deduced using average thermal neutron flux in reference water samples and thermal flux measurements with the aid of a 3He neutron detector. The average absolute gamma detection efficiency is determined using the prompt gammas emitted by chlorine dissolved in a water sample. The gamma detection efficiency is normalized for sludge samples using gamma attenuation factors calculated with the MCNP5 code for water and sludge. Wet and dehydrated sludge samples were analyzed. Nutritive elements (Ca, N, P, K) and heavy metals elements like Cr and Mn were determined. For some elements, the PGNAA values were compared to those obtained using Atomic Absorption Spectroscopy (AAS) and Inductively Coupled Plasma (ICP) methods. Good agreement is observed between the different values. Heavy element concentrations are very high compared to normal values; this is related to the fact that the wastewater treatment plant is treating not only domestic but also industrial wastewater that is probably rejected by industries without removal of pollutant elements. The detection limits for almost all elements of interest are sufficiently low for the method to be well suited for such analysis.

  17. Evaluation of mean-monthly streamflow-regression equations for Colorado, 2014

    USGS Publications Warehouse

    Kohn, Michael S.; Stevens, Michael R.; Bock, Andrew R.; Char, Stephen J.

    2015-01-01

    The median absolute differences between the observed and computed mean-monthly streamflow for Mountain, Northwest, and Southwest hydrologic regions are fairly uniform throughout the year, with the exception of late summer and early fall (July, August, and September), when each hydrologic region exhibits a substantial increase in median absolute percent difference. The greatest difference occurs in the Northwest hydrologic region, and the smallest difference occurs in the Mountain hydrologic region. The Rio Grande hydrologic region shows seasonal variation in median absolute percent difference with March, April, August, and September having a median absolute difference near or below 40 percent, and the remaining months of the year having a median absolute difference near or above 50 percent. In the Mountain, Northwest, and Southwest hydrologic regions, the mean-monthly streamflow equations perform the best during spring (March, April, and May). However, in the Rio Grande hydrologic region, the mean-monthly streamflow equations perform the best during late summer and early fall (August and September).

  18. The Absolute Reflectance and New Calibration Site of the Moon

    NASA Astrophysics Data System (ADS)

    Wu, Yunzhao; Wang, Zhenchao; Cai, Wei; Lu, Yu

    2018-05-01

    How bright the Moon is forms a simple but fundamental and important question. Although numerous efforts have been made to answer this question such as use of sophisticated electro-optical measurements and suggestions for calibration sites, the answer is still debated. An in situ measurement with a calibration panel on the surface of the Moon is crucial for obtaining the accurate absolute reflectance and resolving the debate. China’s Chang’E-3 (CE-3) “Yutu” rover accomplished this type of measurement using the Visible-Near Infrared Spectrometer (VNIS). The measurements of the VNIS, which were at large emission and phase angles, complement existing measurements for the range of photometric geometry. The in situ reflectance shows that the CE-3 landing site is very dark with an average reflectance of 3.86% in the visible bands. The results are compared with recent mission instruments: the Lunar Reconnaissance Orbiter Camera (LROC) Wide Angle Camera (WAC), the Spectral Profiler (SP) on board the SELENE, the Moon Mineralogy Mapper (M3) on board the Chandrayaan-1, and the Chang’E-1 Interference Imaging Spectrometer (IIM). The differences in the measurements of these instruments are very large and indicate inherent differences in their absolute calibration. The M3 and IIM measurements are smaller than LROC WAC and SP, and the VNIS measurement falls between these two pairs. When using the Moon as a radiance source for the on-orbit calibration of spacecraft instruments, one should be cautious about the data. We propose that the CE-3 landing site, a young and homogeneous surface, should serve as the new calibration site.

  19. Unique strain history during ejection in canine left ventricle.

    PubMed

    Douglas, A S; Rodriguez, E K; O'Dell, W; Hunter, W C

    1991-05-01

    Understanding the relationship between structure and function in the heart requires a knowledge of the connection between the local behavior of the myocardium (e.g., shortening) and the pumping action of the left ventricle. We asked the question, how do changes in preload and afterload affect the relationship between local myocardial deformation and ventricular volume? To study this, a set of small radiopaque beads was implanted in approximately 1 cm3 of the isolated canine heart left ventricular free wall. Using biplane cineradiography, we tracked the motion of these markers through various cardiac cycles (controlling pre- and afterload) using the relative motion of six markers to quantify the local three dimensional Lagrangian strain. Two different reference states (used to define the strains) were considered. First, we used the configuration of the heart at end diastole for that particular cardiac cycle to define the individual strains (which gave the local "shortening fraction") and the ejection fraction. Second, we used a single reference state for all cardiac cycles i.e., the end-diastolic state at maximum volume, to define absolute strains (which gave local fractional length) and the volume fraction. The individual strain versus ejection fraction trajectories were dependent on preload and afterload. For any one heart, however, each component of absolute strain was more tightly correlated to volume fraction. Around each linear regression, the individual measurements of absolute strain scattered with standard errors that averaged less than 7% of their range. Thus the canine hearts examined had a preferred kinematic (shape) history during ejection, different from the kinematics of filling and independent or pre-or afterload and of stroke volume.

  20. Demand forecasting of electricity in Indonesia with limited historical data

    NASA Astrophysics Data System (ADS)

    Dwi Kartikasari, Mujiati; Rohmad Prayogi, Arif

    2018-03-01

    Demand forecasting of electricity is an important activity for electrical agents to know the description of electricity demand in future. Prediction of demand electricity can be done using time series models. In this paper, double moving average model, Holt’s exponential smoothing model, and grey model GM(1,1) are used to predict electricity demand in Indonesia under the condition of limited historical data. The result shows that grey model GM(1,1) has the smallest value of MAE (mean absolute error), MSE (mean squared error), and MAPE (mean absolute percentage error).

  1. Energy dispersive X-ray analysis on an absolute scale in scanning transmission electron microscopy.

    PubMed

    Chen, Z; D'Alfonso, A J; Weyland, M; Taplin, D J; Allen, L J; Findlay, S D

    2015-10-01

    We demonstrate absolute scale agreement between the number of X-ray counts in energy dispersive X-ray spectroscopy using an atomic-scale coherent electron probe and first-principles simulations. Scan-averaged spectra were collected across a range of thicknesses with precisely determined and controlled microscope parameters. Ionization cross-sections were calculated using the quantum excitation of phonons model, incorporating dynamical (multiple) electron scattering, which is seen to be important even for very thin specimens. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Note: An absolute X-Y-Θ position sensor using a two-dimensional phase-encoded binary scale

    NASA Astrophysics Data System (ADS)

    Kim, Jong-Ahn; Kim, Jae Wan; Kang, Chu-Shik; Jin, Jonghan

    2018-04-01

    This Note presents a new absolute X-Y-Θ position sensor for measuring planar motion of a precision multi-axis stage system. By analyzing the rotated image of a two-dimensional phase-encoded binary scale (2D), the absolute 2D position values at two separated points were obtained and the absolute X-Y-Θ position could be calculated combining these values. The sensor head was constructed using a board-level camera, a light-emitting diode light source, an imaging lens, and a cube beam-splitter. To obtain the uniform intensity profiles from the vignette scale image, we selected the averaging directions deliberately, and higher resolution in the angle measurement could be achieved by increasing the allowable offset size. The performance of a prototype sensor was evaluated in respect of resolution, nonlinearity, and repeatability. The sensor could resolve 25 nm linear and 0.001° angular displacements clearly, and the standard deviations were less than 18 nm when 2D grid positions were measured repeatedly.

  3. Zero absolute vorticity: insight from experiments in rotating laminar plane Couette flow.

    PubMed

    Suryadi, Alexandre; Segalini, Antonio; Alfredsson, P Henrik

    2014-03-01

    For pressure-driven turbulent channel flows undergoing spanwise system rotation, it has been observed that the absolute vorticity, i.e., the sum of the averaged spanwise flow vorticity and system rotation, tends to zero in the central region of the channel. This observation has so far eluded a convincing theoretical explanation, despite experimental and numerical evidence reported in the literature. Here we show experimentally that three-dimensional laminar structures in plane Couette flow, which appear under anticyclonic system rotation, give the same effect, namely, that the absolute vorticity tends to zero if the rotation rate is high enough. It is shown that this is equivalent to a local Richardson number of approximately zero, which would indicate a stable condition. We also offer an explanation based on Kelvin's circulation theorem to demonstrate that the absolute vorticity should remain constant and approximately equal to zero in the central region of the channel when going from the nonrotating fully turbulent state to any state with sufficiently high rotation.

  4. 40 CFR 1066.310 - Coastdown procedures for vehicles above 14,000 pounds GVWR.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Calibrate the equipment by running the zero-wind and zero-angle calibrations within 24 hours before... = mean ambient absolute temperature during testing, in K. p act = average ambient pressuring during the...

  5. SU-F-T-472: Validation of Absolute Dose Measurements for MR-IGRT With and Without Magnetic Field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, O; Li, H; Goddu, S

    Purpose: To validate absolute dose measurements for a MR-IGRT system without presence of the magnetic field. Methods: The standard method (AAPM’s TG-51) of absolute dose measurement with ionization chambers was tested with and without the presence of the magnetic field for a clinical 0.32-T Co-60 MR-IGRT system. Two ionization chambers were used - the Standard Imaging (Madison, WI) A18 (0.123 cc) and the PTW (Freiburg, Germany). A previously reported Monte Carlo simulation suggested a difference on the order of 0.5% for dose measured with and without the presence of the magnetic field, but testing this was not possible until anmore » engineering solution to allow the radiation system to be used without the nominal magnetic field was found. A previously identified effect of orientation in the magnetic field was also tested by placing the chamber either parallel or perpendicular to the field and irradiating from two opposing angles (90 and 270). Finally, the Imaging and Radiation Oncology Core provided OSLD detectors for five irradiations each with and without the field - with two heads at both 0 and 90 degrees, and one head at 90 degrees only as it doesn’t reach 0 (IEC convention). Results: For the TG-51 comparison, expected dose was obtained by decaying values measured at the time of source installation. The average measured difference was 0.4%±0.12% for A18 and 0.06%±0.15% for Farmer chamber. There was minimal (0.3%) orientation dependence without the magnetic field for the A18 chamber, while previous measurements with the magnetic field had a deviation of 3.2% with chamber perpendicular to magnetic field. Results reported by IROC for the OSLDs with and without the field had a maximum difference of 2%. Conclusion: Accurate absolute dosimetry was verified by measurement under the same conditions with and without the magnetic field for both ionization chambers and independently-verifiable OSLDs.« less

  6. Study on Growth Rhythm of Juveniles Cistolemmys Flavomarginata for One and Two Years Old

    NASA Astrophysics Data System (ADS)

    Huang, Bin

    Growth of one and two year old Cistolemmys flavomarginata is studied. In natural temperature and under artificial feeding condition, juvenile turtles grow for 180 days in Xinyang, one year old turtle average body weight increased from 18.1 g to 54.5 g, the relative growth rate is 204.1%, the absolute growth rate is 0.21. two year old turtle average body weight increased from 46.8 g to 101.1 g, the relative growth rate is 115.98%, the absolute growth rate is 0.30. But two year old turtle growth rate is slower than that of one year old turtle. The body weight, carapace length, carapace width, plastron length, plastron width and carapace high are correlated positively to daily age. The body weight growth equations of one and two year old turtles are deduced. Compared with other reptiles, whole growth cycle is grasped systemically by the growth patterns.

  7. The two radii of a charged particle.

    PubMed

    Michov, B M

    1989-01-01

    The existence of two radii of each charged particle-a geometric and electrokinetic radii, is supposed. The mathematical relationship between them in the four possible combinations of an ion and its counterion is analyzed: (i) at equal geometric radii and, in absolute values, equal valencies; (ii) at equal geometric radii and, in absolute values, different valencies; (iii) at different geometric radii and, in absolute values, equal valencies; (iv) at different geometric radii and, in absolute values, different valencies. One of the equations worked out can be used to define the relationship between the geometric and electrokinetic radii of a polyion. All the equations are used in working out precise calculations.

  8. Study of T-wave morphology parameters based on Principal Components Analysis during acute myocardial ischemia

    NASA Astrophysics Data System (ADS)

    Baglivo, Fabricio Hugo; Arini, Pedro David

    2011-12-01

    Electrocardiographic repolarization abnormalities can be detected by Principal Components Analysis of the T-wave. In this work we studied the efect of signal averaging on the mean value and reproducibility of the ratio of the 2nd to the 1st eigenvalue of T-wave (T21W) and the absolute and relative T-wave residuum (TrelWR and TabsWR) in the ECG during ischemia induced by Percutaneous Coronary Intervention. Also, the intra-subject and inter-subject variability of T-wave parameters have been analyzed. Results showed that TrelWR and TabsWR evaluated from the average of 10 complexes had lower values and higher reproducibility than those obtained from 1 complex. On the other hand T21W calculated from 10 complexes did not show statistical diferences versus the T21W calculated on single beats. The results of this study corroborate that, with a signal averaging technique, the 2nd and the 1st eigenvalue are not afected by noise while the 4th to 8th eigenvalues are so much afected by this, suggesting the use of the signal averaged technique before calculation of absolute and relative T-wave residuum. Finally, we have shown that T-wave morphology parameters present high intra-subject stability.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wen, N; Lu, S; Qin, Y

    Purpose: To evaluate the dosimetric uncertainty associated with Gafchromic (EBT3) films and establish an absolute dosimetry protocol for Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiotherapy (SBRT). Methods: EBT3 films were irradiated at each of seven different dose levels between 1 and 15 Gy with open fields, and standard deviations of dose maps were calculated at each color channel for evaluation. A scanner non-uniform response correction map was built by registering and comparing film doses to the reference diode array-based dose map delivered with the same doses. To determine the temporal dependence of EBT3 films, the average correction factors of differentmore » dose levels as a function of time were evaluated up to four days after irradiation. An integrated film dosimetry protocol was developed for dose calibration, calibration curve fitting, dose mapping, and profile/gamma analysis. Patient specific quality assurance (PSQA) was performed for 93 SRS/SBRT treatment plans. Results: The scanner response varied within 1% for the field sizes less than 5 × 5 cm{sup 2}, and up to 5% for the field sizes of 10 × 10 cm{sup 2}. The scanner correction method was able to remove visually evident, irregular detector responses found for larger field sizes. The dose response of the film changed rapidly (∼10%) in the first two hours and plateaued afterwards, ∼3% change between 2 and 24 hours. The mean uncertainties (mean of the standard deviations) were <0.5% over the dose range 1∼15Gy for all color channels for the OD response curves. The percentage of points passing the 3%/1mm gamma criteria based on absolute dose analysis, averaged over all tests, was 95.0 ± 4.2. Conclusion: We have developed an absolute film dose dosimetry protocol using EBT3 films. The overall uncertainty has been established to be approximately 1% for SRS and SBRT PSQA. The work was supported by a Research Scholar Grant, RSG-15-137-01-CCE from the American Cancer Society.« less

  10. Is there a clinical benefit with a smooth compensator design compared with a plunged compensator design for passive scattered protons?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tabibian, Art A., E-mail: art.tabibian@gmail.com; Powers, Adam; Dolormente, Keith

    In proton therapy, passive scattered proton plans use compensators to conform the dose to the distal surface of the planning volume. These devices are custom made from acrylic or wax for each treatment field using either a plunge-drilled or smooth-milled compensator design. The purpose of this study was to investigate if there is a clinical benefit of generating passive scattered proton radiation treatment plans with the smooth compensator design. We generated 4 plans with different techniques using the smooth compensators. We chose 5 sites and 5 patients for each site for the range of dosimetric effects to show adequate sample.more » The plans were compared and evaluated using multicriteria (MCA) plan quality metrics for plan assessment and comparison using the Quality Reports [EMR] technology by Canis Lupus LLC. The average absolute difference for dosimetric metrics from the plunged-depth plan ranged from −4.7 to +3.0 and the average absolute performance results ranged from −6.6% to +3%. The manually edited smooth compensator plan yielded the best dosimetric metric, +3.0, and performance, + 3.0% compared to the plunged-depth plan. It was also superior to the other smooth compensator plans. Our results indicate that there are multiple approaches to achieve plans with smooth compensators similar to the plunged-depth plans. The smooth compensators with manual compensator edits yielded equal or better target coverage and normal tissue (NT) doses compared with the other smooth compensator techniques. Further studies are under investigation to evaluate the robustness of the smooth compensator design.« less

  11. Treatment decision-making and the form of risk communication: results of a factorial survey.

    PubMed

    Hembroff, Larry A; Holmes-Rovner, Margaret; Wills, Celia E

    2004-11-16

    Prospective users of preventive therapies often must evaluate complex information about therapeutic risks and benefits. The purpose of this study was to evaluate the effect of relative and absolute risk information on patient decision-making in scenarios typical of health information for patients. Factorial experiments within a telephone survey of the Michigan adult, non-institutionalized, English-speaking population. Average interview lasted 23 minutes. Subjects and sample design: 952 randomly selected adults within a random-digit dial sample of Michigan households. Completion rate was 54.3%. When presented hypothetical information regarding additional risks of breast cancer from a medication to prevent a bone disease, respondents reduced their willingness to recommend a female friend take the medication compared to the baseline rate (66.8% = yes). The decrease was significantly greater with relative risk information. Additional benefit information regarding preventing heart disease from the medication increased willingness to recommend the medication to a female friend relative to the baseline scenario, but did not differ between absolute and relative risk formats. When information about both increased risk of breast cancer and reduced risk of heart disease were provided, typical respondents appeared to make rational decisions consistent with Expected Utility Theory, but the information presentation format affected choices. Those 11% - 33% making decisions contrary to the medical indications were more likely to be Hispanic, older, more educated, smokers, and to have children in the home. In scenarios typical of health risk information, relative risk information led respondents to make non-normative decisions that were "corrected" when the frame used absolute risk information. This population sample made generally rational decisions when presented with absolute risk information, even in the context of a telephone interview requiring remembering rates given. The lack of effect of gender and race suggests that a standard strategy of presenting absolute risk information may improve patient decision-making.

  12. The effects of season, aeration and light intensity on the performance of pacific whiteleg shrimp (Litopenaeus vannamei) polycultured with seaweed (Gracilaria verrucosa)

    NASA Astrophysics Data System (ADS)

    Susilowati, T.; Desrina; Hutabarat, J.; Anggoro, S.; Zainuri, M.; Sarjito; Basuki, F.; Yuniarti, T.

    2018-04-01

    This study was aimed to determine impact of stocking season, additional oxygen supply and light intensity on performance of pacific white leg shrimp (Litopenaeus vannamei) polycultured with seaweed Gracilaria verrucosa. Three sets of experiments were used and each experiment was conducted separately in 3 different season (factor W). Three factors and the interaction, that is, stocking seasons (W1: March-June;. W2 : July-October and W3 : November-February), Oxygen supply (O, with or without supply aeration of 6.5 ppm) and light intensity (with or without addition of light 640 lux) was observed. The experiment was conducted in 16 polyethilen net place in concrete tanks (1.2 m3). Shrimp (average weight 0.1 g and lenght 1.2 cm) with density 94 shrimp/m3 and seaweed 2.188 g/m3, cultured for 94 days. Data collected included absolute growth, specific growth rate (SGR), survival rate (SR) and biomass production of shrimp and seaweed. The result showed that culture period March to June, additonal light and suply DO gave the best result with shrimp absolute growth 13.23 g, SGR 5.09 %/day, SR 99.64 % and biomass production 1.256.36 g/m3. Absolute growth of G. verrucosa was 5.223.75g, SGR 268 %/day and biomass production 12.608.55 g/m3.

  13. Measurements of the Acoustic Speaking Voice After Vocal Warm-up and Cooldown in Choir Singers.

    PubMed

    Onofre, Fernanda; Prado, Yuka de Almeida; Rojas, Gleidy Vannesa E; Garcia, Denny Marco; Aguiar-Ricz, Lílian

    2017-01-01

    The aim of this study was to evaluate the acoustic measurements of the vowel /a/ in modal recording before and after a singing voice resistance test and after 30 minutes of absolute rest in female choir singers. This is a prospective cohort study. A total of 13 soprano choir singers with experience in choir singing were evaluated through analysis of acoustic voice parameters at three points in time: before continuous use of the voice, after vocal warm-up and a singing test 60 minutes in duration respecting the pauses for breathing, and after vocal cooldown and an absolute voice rest for 30 minutes. The fundamental frequency increased after the voice resistance test (P = 0.012) and remained elevated after the 30 minutes of voice rest (P = 0.01). The jitter decreased after the voice resistance test (P = 0.02) and after the 30 minutes of voice rest. A significant difference was detected for the acoustic voice parameters relative average perturbation (RAP), (P = 0.05), and pitch perturbation quotient (PPQ), (P = 0.04), compared with the initial time point. The fundamental frequency increased after 60 minutes of singing and remained elevated after vocal cooldown and absolute rest for 30 minutes, proving an efficient parameter for identifying the changes inherent to voice demand during singing. Copyright © 2017. Published by Elsevier Inc.

  14. Lower limb alactic anaerobic power output assessed with different techniques in morbid obesity.

    PubMed

    Lafortuna, C L; Fumagalli, E; Vangeli, V; Sartorio, A

    2002-02-01

    Short-term alactic anaerobic performance in jumping (5 consecutive jumps with maximal effort), sprint running (8 m) and stair climbing (modified Margaria test) were measured in 75 obese subjects (BMI: 40.3+/-5.0 kg/m2) and in 36 lean control subjects (BMI: 22.4+/-3.2 kg/m2) of the same age and gender distribution. The results show that obese subjects attained a significantly lower specific (per unit body mass) power output both in jumping (W(spec,j); p<0.001) and stair climbing (W(spec,s); p<0.001) and run at a significantly lower average velocity (v; p<0.001) during sprinting. In spite of the different motor skillfulness required to accomplish the jumping and climbing tests, W(spec,s) (and hence the vertical velocity in climbing, v(v)) was closely correlated with W(spec,j) (R2=0.427, p<0.001). In jumping, although the average force during the positive work phase was significantly higher in obese subjects (p<0.001), no difference between the 2 groups was detected in absolute power. In stair climbing the absolute power output of obese resulted significantly higher (18%) than that of lean controls (p<0.001). In sprint running, the lower average horizontal velocity attained by obese subjects also entailed a different locomotion pattern with shorter step length (L(s); p<0.001), lower frequency (p<0.001) and longer foot contact time with ground (T(c,r); p<0.001). W(spec,j) seems to be a determinant of the poorer motor performance of obese, being significantly correlated with: I) the vertical displacement of the centre of gravity (R2=0.853, p<0.001) in jumping; II) with v(v) in stair climbing; and III) with T(c,r) (R2=0.492, p<0.001), L(s) (R2=0.266, p<0.001) and v (R2=0.454, p<0.001) in sprinting. The results suggest that obese individuals, although partially hampered in kinetic movements, largely rely on their effective specific power output to perform complex anaerobic tasks, and they suffer from the disproportionate excess of inert mass of fat. Furthermore, in view of the sedentary style of life and the consequent degree of muscle de-conditioning accompanying this condition, it may prove useful to implement rehabilitation programs for obesity with effective power training protocols.

  15. Evaluation of the Repeatability and Accuracy of the Wideband Real-Ear-to-Coupler Difference.

    PubMed

    Vaisberg, Jonathan M; Folkeard, Paula; Pumford, John; Narten, Philipp; Scollie, Susan

    2018-06-01

    The real-ear-to-coupler difference (RECD) is an ANSI standardized method for estimating ear canal sound pressure level (SPL) thresholds and assisting in the prediction of real-ear aided responses. It measures the difference in dB between the SPL produced in the ear canal and the SPL produced in an HA-1 2-cc coupler by the same sound source. Recent evidence demonstrates that extended high-frequency bandwidth, beyond the hearing aid bandwidth typically measured, is capable of providing additional clinical benefit. The industry has, in turn, moved toward developing hearing aids and verification equipment capable of producing and measuring extended high-frequency audible output. As a result, a revised RECD procedure conducted using a smaller, 0.4-cc coupler, known as the wideband-RECD (wRECD), has been introduced to facilitate extended high-frequency coupler-based measurements up to 12.5 kHz. This study aimed to (1) compare test-retest repeatability between the RECD and wRECD and (2) measure absolute agreement between the RECD and wRECD when both are referenced to a common coupler. RECDs and wRECDs were measured bilaterally in adult ears by calculating the dB difference in SPL between the ear canal and coupler responses. Real-ear probe microphone measures were completed twice per ear per participant for both foam-tip and customized earmold couplings using the Audioscan Verifit 1 and Verifit 2 fitting systems, followed by measurements in the respective couplers. Twenty-one adults (mean age = 67 yr, range = 19-78) with typical aural anatomy (as determined by measures of impedance and otoscopy) participated in this study, leading to a sample size of 42 ears. Repeatability within RECD and wRECD was assessed for each coupling configuration using a repeated-measures analysis of variance (ANOVA) with test-retest and frequency as within-participants factors. Repeatability between the RECD and wRECD was assessed within each configuration using a repeated-measures ANOVA with test-retest, frequency, and coupler type as within-participants factors. Agreement between the RECD and wRECD was assessed for each coupling configuration using a repeated-measures ANOVA with RECD value, coupler type, and frequency as within-participants factors. Post hoc comparisons with Bonferroni corrections were used when appropriate to locate the frequencies at which differences occurred. A 3-dB criterion was defined to locate differences of clinical significance. Average absolute test-retest differences were within ±3 dB within each coupler and coupling configuration, and between the RECD and wRECD. The RECD and wRECD were in absolute agreement following HA-1-referenced transforms, with most frequencies agreeing within ±1 dB, except at 0.2 kHz for the earmold, and 0.2-0.25 kHz for the foam tip, where the average RECD exceeded the average wRECD by slightly >3 dB. Test-retest repeatability of the RECD (up to 8 kHz) and wRECD (up to 12.5 kHz) is acceptable and similar to previously reported data. The RECD and wRECD are referenced to different couplers, but can be rendered comparable with a simple transform, producing values that are in accordance with the ANSI S3.46-2013 standard. American Academy of Audiology.

  16. Waist circumference values equivalent to body mass index points for predicting absolute cardiovascular disease risks among adults in an Aboriginal community: a prospective cohort study.

    PubMed

    Adegbija, Odewumi; Hoy, Wendy E; Wang, Zhiqiang

    2015-11-13

    There have been suggestions that currently recommended waist circumference (WC) cut-off points for Australians of European origin may not be applicable to Aboriginal people who have different body habitus profiles. We aimed to generate equivalent WC values that correspond to body mass index (BMI) points for identifying absolute cardiovascular disease (CVD) risks. Prospective cohort study. An Aboriginal community in Australia's Northern Territory. From 1992 to 1998, 920 adults without CVD, with age, WC and BMI measurements were followed-up for up to 20 years. Incident CVD, coronary artery disease (CAD) and heart failure (HF) events during the follow-up period ascertained from hospitalisation data. We generated WC values with 10-year absolute risks equivalent for the development of CVD as BMI values (20-34 kg/m(2)) using the Weibull accelerated time-failure model. There were 211 incident cases of CVD over 13,669 person-years of follow-up. At the average age of 35 years, WC values with absolute CVD, CAD and HF risks equivalent to BMI of 25 kg/m(2) were 91.5, 91.8 and 91.7 cm, respectively, for males, and corresponding WC values were 92.5, 92.7 and 93 cm for females. WC values with equal absolute CVD, CAD and HF risks to BMI of 30 kg/m(2) were 101.7, 103.1 and 102.6 cm, respectively, for males, and corresponding values were 99.2, 101.6 and 101.5 cm for females. Association between WC and CVD did not depend on gender (p=0.54). WC ranging from 91 to 93 cm was equivalent to BMI 25 kg/m(2) for overweight, and 99 to 103 cm was equivalent to BMI of 30 kg/m(2) for obesity in terms of predicting 10-year absolute CVD risk. Replicating the absolute risk method in other Aboriginal communities will further validate the WC values generated for future development of WC cut-off points for Aboriginal people. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Effective dynamics of a random walker on a heterogeneous ring: Exact results

    NASA Astrophysics Data System (ADS)

    Masharian, S. R.

    2018-07-01

    In this paper, by considering a biased random walker hopping on a one-dimensional lattice with a ring geometry, we investigate the fluctuations of the speed of the random walker. We assume that the lattice is heterogeneous i.e. the hopping rate of the random walker between the first and the last lattice sites is different from the hopping rate of the random walker between the other links of the lattice. Assuming that the average speed of the random walker in the steady-state is v∗, we have been able to find the unconditional effective dynamics of the random walker where the absolute value of the average speed of the random walker is -v∗. Using a perturbative method in the large system-size limit, we have also been able to show that the effective hopping rates of the random walker near the defective link are highly site-dependent.

  18. Levels at gaging stations

    USGS Publications Warehouse

    Kenney, Terry A.

    2010-01-01

    Operational procedures at U.S. Geological Survey gaging stations include periodic leveling checks to ensure that gages are accurately set to the established gage datum. Differential leveling techniques are used to determine elevations for reference marks, reference points, all gages, and the water surface. The techniques presented in this manual provide guidance on instruments and methods that ensure gaging-station levels are run to both a high precision and accuracy. Levels are run at gaging stations whenever differences in gage readings are unresolved, stations may have been damaged, or according to a pre-determined frequency. Engineer's levels, both optical levels and electronic digital levels, are commonly used for gaging-station levels. Collimation tests should be run at least once a week for any week that levels are run, and the absolute value of the collimation error cannot exceed 0.003 foot/100 feet (ft). An acceptable set of gaging-station levels consists of a minimum of two foresights, each from a different instrument height, taken on at least two independent reference marks, all reference points, all gages, and the water surface. The initial instrument height is determined from another independent reference mark, known as the origin, or base reference mark. The absolute value of the closure error of a leveling circuit must be less than or equal to ft, where n is the total number of instrument setups, and may not exceed |0.015| ft regardless of the number of instrument setups. Closure error for a leveling circuit is distributed by instrument setup and adjusted elevations are determined. Side shots in a level circuit are assessed by examining the differences between the adjusted first and second elevations for each objective point in the circuit. The absolute value of these differences must be less than or equal to 0.005 ft. Final elevations for objective points are determined by averaging the valid adjusted first and second elevations. If final elevations indicate that the reference gage is off by |0.015| ft or more, it must be reset.

  19. Mainstem Clearwater River Study: Assessment for Salmonid Spawning, Incubation, and Rearing.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conner, William P.

    1989-01-01

    Chinook salmon reproduced naturally in the Clearwater River until damming of the lower mainstem in 1927 impeded upstream spawning migrations and decimated the populations. Removal of the Washington Water Power Dam in 1973 reopened upriver passage. This study was initiated to determine the feasibility of re-introducing chinook salmon into the lower mainstem Clearwater River based on the temperature and flow regimes, water quality, substrate, and invertebrate production since the completion of Dworshak Dam in 1972. Temperature data obtained from the United States Geological Survey gaging stations at Peck and Spalding, Idaho, were used to calculate average minimum and maximum watermore » temperature on a daily, monthly and yearly basis. The coldest and warmest (absolute minimum and maximum) temperatures that have occurred in the past 15 years were also identified. Our analysis indicates that average lower mainstem Clearwater River water temperatures are suitable for all life stages of chinook salmon, and also for steelhead trout rearing. In some years absolute maximum water temperatures in late summer may postpone adult staging and spawning. Absolute minimum temperatures have been recorded that could decrease overwinter survival of summer chinook juveniles and fall chinook eggs depending on the quality of winter hiding cover and the prevalence of intra-gravel freezing in the lower mainstem Clearwater River.« less

  20. Jasminum sambac flower absolutes from India and China--geographic variations.

    PubMed

    Braun, Norbert A; Sim, Sherina

    2012-05-01

    Seven Jasminum sambac flower absolutes from different locations in the southern Indian state of Tamil Nadu were analyzed using GC and GC-MS. Focus was placed on 41 key ingredients to investigate geographic variations in this species. These seven absolutes were compared with an Indian bud absolute and commercially available J. sambac flower absolutes from India and China. All absolutes showed broad variations for the 10 main ingredients between 8% and 96%. In addition, the odor of Indian and Chinese J. sambac flower absolutes were assessed.

  1. Communicating cardiovascular disease risk: an interview study of General Practitioners’ use of absolute risk within tailored communication strategies

    PubMed Central

    2014-01-01

    Background Cardiovascular disease (CVD) prevention guidelines encourage assessment of absolute CVD risk - the probability of a CVD event within a fixed time period, based on the most predictive risk factors. However, few General Practitioners (GPs) use absolute CVD risk consistently, and communication difficulties have been identified as a barrier to changing practice. This study aimed to explore GPs’ descriptions of their CVD risk communication strategies, including the role of absolute risk. Methods Semi-structured interviews were conducted with a purposive sample of 25 GPs in New South Wales, Australia. Transcribed audio-recordings were thematically coded, using the Framework Analysis method to ensure rigour. Results GPs used absolute CVD risk within three different communication strategies: ‘positive’, ‘scare tactic’, and ‘indirect’. A ‘positive’ strategy, which aimed to reassure and motivate, was used for patients with low risk, determination to change lifestyle, and some concern about CVD risk. Absolute risk was used to show how they could reduce risk. A ‘scare tactic’ strategy was used for patients with high risk, lack of motivation, and a dismissive attitude. Absolute risk was used to ‘scare’ them into taking action. An ‘indirect’ strategy, where CVD risk was not the main focus, was used for patients with low risk but some lifestyle risk factors, high anxiety, high resistance to change, or difficulty understanding probabilities. Non-quantitative absolute risk formats were found to be helpful in these situations. Conclusions This study demonstrated how GPs use three different communication strategies to address the issue of CVD risk, depending on their perception of patient risk, motivation and anxiety. Absolute risk played a different role within each strategy. Providing GPs with alternative ways of explaining absolute risk, in order to achieve different communication aims, may improve their use of absolute CVD risk assessment in practice. PMID:24885409

  2. Online absolute pose compensation and steering control of industrial robot based on six degrees of freedom laser measurement

    NASA Astrophysics Data System (ADS)

    Yang, Juqing; Wang, Dayong; Fan, Baixing; Dong, Dengfeng; Zhou, Weihu

    2017-03-01

    In-situ intelligent manufacturing for large-volume equipment requires industrial robots with absolute high-accuracy positioning and orientation steering control. Conventional robots mainly employ an offline calibration technology to identify and compensate key robotic parameters. However, the dynamic and static parameters of a robot change nonlinearly. It is not possible to acquire a robot's actual parameters and control the absolute pose of the robot with a high accuracy within a large workspace by offline calibration in real-time. This study proposes a real-time online absolute pose steering control method for an industrial robot based on six degrees of freedom laser tracking measurement, which adopts comprehensive compensation and correction of differential movement variables. First, the pose steering control system and robot kinematics error model are constructed, and then the pose error compensation mechanism and algorithm are introduced in detail. By accurately achieving the position and orientation of the robot end-tool, mapping the computed Jacobian matrix of the joint variable and correcting the joint variable, the real-time online absolute pose compensation for an industrial robot is accurately implemented in simulations and experimental tests. The average positioning error is 0.048 mm and orientation accuracy is better than 0.01 deg. The results demonstrate that the proposed method is feasible, and the online absolute accuracy of a robot is sufficiently enhanced.

  3. A microcomputed tomography evaluation of the marginal fit of cobalt-chromium alloy copings fabricated by new manufacturing techniques and alloy systems.

    PubMed

    Kim, Eun-Ha; Lee, Du-Hyeong; Kwon, Sung-Min; Kwon, Tae-Yub

    2017-03-01

    Although new digital manufacturing techniques are attracting interest in dentistry, few studies have comprehensively investigated the marginal fit of fixed dental prostheses fabricated with such techniques. The purpose of this in vitro microcomputed tomography (μCT) study was to evaluate the marginal fit of cobalt-chromium (Co-Cr) alloy copings fabricated by casting and 3 different computer-aided design and computer-aided manufacturing (CAD-CAM)-based processing techniques and alloy systems. Single Co-Cr metal crowns were fabricated using 4 different manufacturing techniques: casting (control), milling, selective laser melting, and milling/sintering. Two different commercial alloy systems were used for each fabrication technique (a total of 8 groups; n=10 for each group). The marginal discrepancy and absolute marginal discrepancy of the crowns were determined with μCT. For each specimen, the values were determined from 4 different regions (sagittal buccal, sagittal lingual, coronal mesial, and coronal distal) by using imaging software and recorded as the average of the 4 readings. For each parameter, the results were statistically compared with 2-way analysis of variance and appropriate post hoc analysis (using Tukey or Student t test) (α=.05). The milling and selective laser melting groups showed significantly larger marginal discrepancies than the control groups (70.4 ±12.0 and 65.3 ±10.1 μm, respectively; P<.001), whereas the milling/sintering groups exhibited significantly smaller values than the controls (P=.004). The milling groups showed significantly larger absolute marginal discrepancy than the control groups (137.4 ±29.0 and 139.2 ±18.9 μm, respectively; P<.05). In the selective laser melting and milling/sintering groups, the absolute marginal discrepancy values were material-specific (P<.05). Nonetheless, the milling/sintering groups yielded statistically comparable (P=.935) or smaller (P<.001) absolute marginal discrepancies to the control groups. The findings of this in vitro μCT study showed that the marginal fit values of the Co-Cr alloy greatly depended on the fabrication methods and, occasionally, the alloy systems. Fixed dental prostheses produced by using the milling/sintering technique can be considered clinically acceptable in terms of marginal fit. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. A Simulation-Based Study on the Comparison of Statistical and Time Series Forecasting Methods for Early Detection of Infectious Disease Outbreaks.

    PubMed

    Yang, Eunjoo; Park, Hyun Woo; Choi, Yeon Hwa; Kim, Jusim; Munkhdalai, Lkhagvadorj; Musa, Ibrahim; Ryu, Keun Ho

    2018-05-11

    Early detection of infectious disease outbreaks is one of the important and significant issues in syndromic surveillance systems. It helps to provide a rapid epidemiological response and reduce morbidity and mortality. In order to upgrade the current system at the Korea Centers for Disease Control and Prevention (KCDC), a comparative study of state-of-the-art techniques is required. We compared four different temporal outbreak detection algorithms: the CUmulative SUM (CUSUM), the Early Aberration Reporting System (EARS), the autoregressive integrated moving average (ARIMA), and the Holt-Winters algorithm. The comparison was performed based on not only 42 different time series generated taking into account trends, seasonality, and randomly occurring outbreaks, but also real-world daily and weekly data related to diarrhea infection. The algorithms were evaluated using different metrics. These were namely, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), F1 score, symmetric mean absolute percent error (sMAPE), root-mean-square error (RMSE), and mean absolute deviation (MAD). Although the comparison results showed better performance for the EARS C3 method with respect to the other algorithms, despite the characteristics of the underlying time series data, Holt⁻Winters showed better performance when the baseline frequency and the dispersion parameter values were both less than 1.5 and 2, respectively.

  5. 19 CFR 351.224 - Disclosure of calculations and procedures for the correction of ministerial errors.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... least five absolute percentage points in, but not less than 25 percent of, the weighted-average dumping... margin or countervailable subsidy rate (whichever is applicable) of zero (or de minimis) and a weighted...

  6. 19 CFR 351.224 - Disclosure of calculations and procedures for the correction of ministerial errors.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... least five absolute percentage points in, but not less than 25 percent of, the weighted-average dumping... margin or countervailable subsidy rate (whichever is applicable) of zero (or de minimis) and a weighted...

  7. 19 CFR 351.224 - Disclosure of calculations and procedures for the correction of ministerial errors.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... least five absolute percentage points in, but not less than 25 percent of, the weighted-average dumping... margin or countervailable subsidy rate (whichever is applicable) of zero (or de minimis) and a weighted...

  8. 19 CFR 351.224 - Disclosure of calculations and procedures for the correction of ministerial errors.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... least five absolute percentage points in, but not less than 25 percent of, the weighted-average dumping... margin or countervailable subsidy rate (whichever is applicable) of zero (or de minimis) and a weighted...

  9. 19 CFR 351.224 - Disclosure of calculations and procedures for the correction of ministerial errors.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... least five absolute percentage points in, but not less than 25 percent of, the weighted-average dumping... margin or countervailable subsidy rate (whichever is applicable) of zero (or de minimis) and a weighted...

  10. Fingerprints of flower absolutes using supercritical fluid chromatography hyphenated with high resolution mass spectrometry.

    PubMed

    Santerre, Cyrille; Vallet, Nadine; Touboul, David

    2018-06-02

    Supercritical fluid chromatography hyphenated with high resolution mass spectrometry (SFC-HRMS) was developed for fingerprint analysis of different flower absolutes commonly used in cosmetics field, especially in perfumes. Supercritical fluid chromatography-atmospheric pressure photoionization-high resolution mass spectrometry (SFC-APPI-HRMS) technique was employed to identify the components of the fingerprint. The samples were separated with a porous graphitic carbon (PGC) Hypercarb™ column (100 mm × 2.1 mm, 3 μm) by gradient elution using supercritical CO 2 and ethanol (0.0-20.0 min (2-30% B), 20.0-25.0 min (30% B), 25.0-26.0 min (30-2% B) and 26.0-30.0 min (2% B)) as mobile phase at a flow rate of 1.5 mL/min. In order to compare the SFC fingerprints between five different flower absolutes: Jasminum grandiflorum absolutes, Jasminum sambac absolutes, Narcissus jonquilla absolutes, Narcissus poeticus absolutes, Lavandula angustifolia absolutes from different suppliers and batches, the chemometric procedure including principal component analysis (PCA) was applied to classify the samples according to their genus and their species. Consistent results were obtained to show that samples could be successfully discriminated. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Assessment of differences between repeated pulse wave velocity measurements in terms of 'bias' in the extrapolated cardiovascular risk and the classification of aortic stiffness: is a single PWV measurement enough?

    PubMed

    Papaioannou, T G; Protogerou, A D; Nasothimiou, E G; Tzamouranis, D; Skliros, N; Achimastos, A; Papadogiannis, D; Stefanadis, C I

    2012-10-01

    Currently, there is no recommendation regarding the minimum number of pulse wave velocity (PWV) measurements to optimize individual's cardiovascular risk (CVR) stratification. The aim of this study was to examine differences between three single consecutive and averaged PWV measurements in terms of the extrapolated CVR and the classification of aortic stiffness as normal. In 60 subjects who referred for CVR assessment, three repeated measurements of blood pressure (BP), heart rate and PWV were performed. The reproducibility was evaluated by the intraclass correlation coefficient (ICC) and mean±s.d. of differences. The absolute differences between single and averaged PWV measurements were classified as: ≤0.25, 0.26-0.49, 0.50-0.99 and ≥1 m s(-1). A difference ≥0.5 m s(-1) (corresponding to 7.5% change in CVR, meta-analysis data from >12 000 subjects) was considered as clinically meaningful; PWV values (single or averaged) were classified as normal according to respective age-corrected normal values (European Network data). Kappa statistic was used to evaluate the agreement between classifications. PWV for the first, second and third measurement was 7.0±1.9, 6.9±1.9, 6.9±2.0 m s(-1), respectively (P=0.319); BP and heart rate did not vary significantly. A good reproducibility between single measurements was observed (ICC>0.94, s.d. ranged between 0.43 and 0.64 m s(-1)). A high percent with difference ≥0.5 m s(-1) was observed between: any pair of the three single PWV measurements (26.6-38.3%); the first or second single measurement and the average of the first and second (18.3%); any single measurement and the average of three measurements (10-20%). In only up to 5% a difference ≥0.5 m s(-1) was observed between the average of three and the average of any two PWV measurements. There was no significant agreement regarding PWV classification as normal between: the first or second measurement and the averaged PWV values. There was significant agreement in classification made by the average of the first two and the average of three PWV measurements (κ=0.85, P<0.001). Even when high reproducibility in PWV measurement is succeeded single measurements provide quite variable results in terms of the extrapolated CVR and the classification of aortic stiffness as normal. The average of two PWV measurements provides similar results with the average of three.

  12. Intercomparison Between in situ and AVHRR Polar Pathfinder-Derived Surface Albedo over Greenland

    NASA Technical Reports Server (NTRS)

    Stroeve, Julienne C.; Box, Jason E.; Fowler, Charles; Haran, Terence; Key, Jeffery

    2001-01-01

    The Advanced Very High Resolution (AVHRR) Polar Pathfinder Data (APP) provides the first long time series of consistent, calibrated surface albedo and surface temperature data for the polar regions. Validations of these products have consisted of individual studies that analyzed algorithm performance for limited regions and or time periods. This paper reports on comparisons made between the APP-derived surface albedo and that measured at fourteen automatic weather stations (AWS) around the Greenland ice sheet from January 1997 to August 1998. Results show that satellite-derived surface albedo values are on average 10% less than those measured by the AWS stations. However, the station measurements tend to be biased high by about 4% and thus the differences in absolute albedo may be less (e.g. 6%). In regions of the ice sheet where the albedo variability is small, such as the dry snow facies, the APP albedo uncertainty exceeds the natural variability. Further work is needed to improve the absolute accuracy of the APP-derived surface albedo. Even so, the data provide temporally and spatially consistent estimates of the Greenland ice sheet albedo.

  13. Development of Bio-impedance Analyzer (BIA) for Body Fat Calculation

    NASA Astrophysics Data System (ADS)

    Riyadi, Munawar A.; Nugraha, A.; Santoso, M. B.; Septaditya, D.; Prakoso, T.

    2017-04-01

    Common weight scales cannot assess body composition or determine fat mass and fat-fress mass that make up the body weight. This research propose bio-impedance analysis (BIA) tool capable to body composition assessment. This tool uses four electrodes, two of which are used for 50 kHz sine wave current flow to the body and the rest are used to measure the voltage produced by the body for impedance analysis. Parameters such as height, weight, age, and gender are provided individually. These parameters together with impedance measurements are then in the process to produce a body fat percentage. The experimental result shows impressive repeatability for successive measurements (stdev ≤ 0.25% fat mass). Moreover, result on the hand to hand node scheme reveals average absolute difference of total subjects between two analyzer tools of 0.48% (fat mass) with maximum absolute discrepancy of 1.22% (fat mass). On the other hand, the relative error normalized to Omron’s HBF-306 as comparison tool reveals less than 2% relative error. As a result, the system performance offers good evaluation tool for fat mass in the body.

  14. Uncertainty in coal property valuation in West Virginia: A case study

    USGS Publications Warehouse

    Hohn, M.E.; McDowell, R.R.

    2001-01-01

    Interpolated grids of coal bed thickness are being considered for use in a proposed method for taxation of coal in the state of West Virginia (United States). To assess the origin and magnitude of possible inaccuracies in calculated coal tonnage, we used conditional simulation to generate equiprobable realizations of net coal thickness for two coals on a 7 1/2 min topographic quadrangle, and a third coal in a second quadrangle. Coals differed in average thickness and proportion of original coal that had been removed by erosion; all three coals crop out in the study area. Coal tonnage was calculated for each realization and for each interpolated grid for actual and artificial property parcels, and differences were summarized as graphs of percent difference between tonnage calculated from the grid and average tonnage from simulations. Coal in individual parcels was considered minable for valuation purposes if average thickness in each parcel exceeded 30 inches. Results of this study show that over 75% of the parcels are classified correctly as minable or unminable based on interpolation grids of coal bed thickness. Although between 80 and 90% of the tonnages differ by less than 20% between interpolated values and simulated values, a nonlinear conditional bias might exist in estimation of coal tonnage from interpolated thickness, such that tonnage is underestimated where coal is thin, and overestimated where coal is thick. The largest percent differences occur for parcels that are small in area, although because of the small quantities of coal in question, bias is small on an absolute scale for these parcels. For a given parcel size, maximum apparent overestimation of coal tonnage occurs in parcels with an average coal bed thickness near the minable cutoff of 30 in. Conditional bias in tonnage for parcels having a coal thickness exceeding the cutoff by 10 in. or more is constant for two of the three coals studied, and increases slightly with average thickness for the third coal. ?? 2001 International Association for Mathematical Geology.

  15. Parametric scaling from species relative abundances to absolute abundances in the computation of biological diversity: a first proposal using Shannon's entropy.

    PubMed

    Ricotta, Carlo

    2003-01-01

    Traditional diversity measures such as the Shannon entropy are generally computed from the species' relative abundance vector of a given community to the exclusion of species' absolute abundances. In this paper, I first mention some examples where the total information content associated with a given community may be more adequate than Shannon's average information content for a better understanding of ecosystem functioning. Next, I propose a parametric measure of statistical information that contains both Shannon's entropy and total information content as special cases of this more general function.

  16. Proceedings of the Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting (15th) Held at Washington, DC on 6-8 December 1983,

    DTIC Science & Technology

    1984-04-02

    clock is an absolute technique with a 14 0 • ,4 precision of about 0.1 )us The results of the portable clock experiment indicate that LF sync...also gains direct access to the U. S. primary frequency standard, NBS-6. Access to1 BS-6 makes it possible to set an absolute limit of one part in 10...of the components in these equations are uncorrelated we may take vari- ances of each of these equations and the cross terms will average to zero 117

  17. Breast Cancer Risk From Modifiable and Nonmodifiable Risk Factors Among White Women in the United States

    PubMed Central

    Maas, Paige; Barrdahl, Myrto; Joshi, Amit D.; Auer, Paul L.; Gaudet, Mia M.; Milne, Roger L.; Schumacher, Fredrick R.; Anderson, William F.; Check, David; Chattopadhyay, Subham; Baglietto, Laura; Berg, Christine D.; Chanock, Stephen J.; Cox, David G.; Figueroa, Jonine D.; Gail, Mitchell H.; Graubard, Barry I.; Haiman, Christopher A.; Hankinson, Susan E.; Hoover, Robert N.; Isaacs, Claudine; Kolonel, Laurence N.; Le Marchand, Loic; Lee, I-Min; Lindström, Sara; Overvad, Kim; Romieu, Isabelle; Sanchez, Maria-Jose; Southey, Melissa C.; Stram, Daniel O.; Tumino, Rosario; VanderWeele, Tyler J.; Willett, Walter C.; Zhang, Shumin; Buring, Julie E.; Canzian, Federico; Gapstur, Susan M.; Henderson, Brian E.; Hunter, David J.; Giles, Graham G; Prentice, Ross L.; Ziegler, Regina G.; Kraft, Peter; Garcia-Closas, Montse; Chatterjee, Nilanjan

    2017-01-01

    IMPORTANCE An improved model for risk stratification can be useful for guiding public health strategies of breast cancer prevention. OBJECTIVE To evaluate combined risk stratification utility of common low penetrant single nucleotide polymorphisms (SNPs) and epidemiologic risk factors. DESIGN, SETTING, AND PARTICIPANTS Using a total of 17 171 cases and 19 862 controls sampled from the Breast and Prostate Cancer Cohort Consortium (BPC3) and 5879 women participating in the 2010 National Health Interview Survey, a model for predicting absolute risk of breast cancer was developed combining information on individual level data on epidemiologic risk factors and 24 genotyped SNPs from prospective cohort studies, published estimate of odds ratios for 68 additional SNPs, population incidence rate from the National Cancer Institute-Surveillance, Epidemiology, and End Results Program cancer registry and data on risk factor distribution from nationally representative health survey. The model is used to project the distribution of absolute risk for the population of white women in the United States after adjustment for competing cause of mortality. EXPOSURES Single nucleotide polymorphisms, family history, anthropometric factors, menstrual and/or reproductive factors, and lifestyle factors. MAIN OUTCOMES AND MEASURES Degree of stratification of absolute risk owing to nonmodifiable (SNPs, family history, height, and some components of menstrual and/or reproductive history) and modifiable factors (body mass index [BMI; calculated as weight in kilograms divided by height in meters squared], menopausal hormone therapy [MHT], alcohol, and smoking). RESULTS The average absolute risk for a 30-year-old white woman in the United States developing invasive breast cancer by age 80 years is 11.3%. A model that includes all risk factors provided a range of average absolute risk from 4.4% to 23.5% for women in the bottom and top deciles of the risk distribution, respectively. For women who were at the lowest and highest deciles of nonmodifiable risks, the 5th and 95th percentile range of the risk distribution associated with 4 modifiable factors was 2.9% to 5.0% and 15.5% to 25.0%, respectively. For women in the highest decile of risk owing to nonmodifiable factors, those who had low BMI, did not drink or smoke, and did not use MHT had risks comparable to an average woman in the general population. CONCLUSIONS AND RELEVANCE This model for absolute risk of breast cancer including SNPs can provide stratification for the population of white women in the United States. The model can also identify subsets of the population at an elevated risk that would benefit most from risk-reduction strategies based on altering modifiable factors. The effectiveness of this model for individual risk communication needs further investigation. PMID:27228256

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manaa, M. Riad; Fried, Laurence E.; Kuo, I-Feng W.

    We report gas-phase enthalpies of formation for the set of energetic molecules NTO, DADE, LLM-105, TNT, RDX, TATB, HMX, and PETN using the G2, G3, G4, and ccCA-PS3 quantum composite methods. Calculations for HMX and PETN hitherto represent the largest molecules attempted with these methods. G3 and G4 calculations are typically close to one another, with a larger difference found between these methods and ccCA-PS3. Furthermore there is significant uncertainty in experimental values, the mean absolute deviation between the average experimental value and calculations are 12, 6, 7, and 3 kcal/mol for G2, G3, G4, and ccCA-PS3, respectively.

  19. Universality of Citation Distributions for Academic Institutions and Journals

    PubMed Central

    Chatterjee, Arnab; Ghosh, Asim; Chakrabarti, Bikas K.

    2016-01-01

    Citations measure the importance of a publication, and may serve as a proxy for its popularity and quality of its contents. Here we study the distributions of citations to publications from individual academic institutions for a single year. The average number of citations have large variations between different institutions across the world, but the probability distributions of citations for individual institutions can be rescaled to a common form by scaling the citations by the average number of citations for that institution. We find this feature seems to be universal for a broad selection of institutions irrespective of the average number of citations per article. A similar analysis for citations to publications in a particular journal in a single year reveals similar results. We find high absolute inequality for both these sets, Gini coefficients being around 0.66 and 0.58 for institutions and journals respectively. We also find that the top 25% of the articles hold about 75% of the total citations for institutions and the top 29% of the articles hold about 71% of the total citations for journals. PMID:26751563

  20. Universality of Citation Distributions for Academic Institutions and Journals.

    PubMed

    Chatterjee, Arnab; Ghosh, Asim; Chakrabarti, Bikas K

    2016-01-01

    Citations measure the importance of a publication, and may serve as a proxy for its popularity and quality of its contents. Here we study the distributions of citations to publications from individual academic institutions for a single year. The average number of citations have large variations between different institutions across the world, but the probability distributions of citations for individual institutions can be rescaled to a common form by scaling the citations by the average number of citations for that institution. We find this feature seems to be universal for a broad selection of institutions irrespective of the average number of citations per article. A similar analysis for citations to publications in a particular journal in a single year reveals similar results. We find high absolute inequality for both these sets, Gini coefficients being around 0.66 and 0.58 for institutions and journals respectively. We also find that the top 25% of the articles hold about 75% of the total citations for institutions and the top 29% of the articles hold about 71% of the total citations for journals.

  1. Seismic Anisotropy Beneath Eastern North America: Results from Multi-Event Inversion

    NASA Astrophysics Data System (ADS)

    Li, Y.; Levin, V. L.; Chen, X.

    2017-12-01

    Seismic anisotropy observed from the split core-refracted shear phases reflects upper mantle deformation. To characterize anisotropic signatures beneath eastern North America, we collected observations along a 1300 km long array from James Bay to the Fundy Basin. The averaged splitting parameters of individual sites show uniform fast polarization orientation of 80° and delay times linearly decreasing from 1.0 s in the Appalachians to 0.5 s in the Superior Province. We also see directional variation of fast polarizations at most sites, which is a likely effect of vertical changes in anisotropic properties. For sites with 10 or more observations, we used a multi-event inversion technique to solve for the underlying anisotropic structure. The technique considers the NULL observations from single-event analysis that are excluded from the averaged splitting parameters. For models with a single 100 km thick anisotropic layer with a horizontal fast axis, we find up to 6% of anisotropy in the Appalachian Orogen, equivalent to a splitting delay time of 1.5 s. Anisotropy strength reduces to 1.8% in the Superior Province, equivalent to delay times under 0.5 s. The overall decrease in anisotropic strength is modified by local changes of up to 2%, suggesting small-scale local variations near the surface. Orientations of the fast axes change from 60° in the Appalachian Orogen to 90° in the Superior Province, and are also modulated by local deviations. In the Appalachian Orogen the fast axes are close to the absolute plate motion in a hot-spot reference frame, while those in the Superior Province differ from it by almost 30°. Average values of splitting delays agree well with results of inversions in the Superior Province, and diverge in the Appalachians. Conversely, averaged fast polarizations match inversion results in the Appalachians, and are systematically different in the Superior Province. For an set of sites with recording periods exceeding 5 years, we will test more complicated models of anisotropy, including dipping fast axes and multiple layers. Figure 1. The best fit anisotropic parameters, orientations of fast axes (top) and strength of anisotropy (bottom), assuming a single 100 km thick horizontal layer with a horizontal fast axis. The red line in top represents the absolute plate motion in a hot spot reference frame.

  2. Health economic modeling of the potential cost saving effects of Neurally Adjusted Ventilator Assist.

    PubMed

    Hjelmgren, Jonas; Bruce Wirta, Sara; Huetson, Pernilla; Myrén, Karl-Johan; Göthberg, Sylvia

    2016-02-01

    Asynchrony between patient and ventilator breaths is associated with increased duration of mechanical ventilation (MV). Neurally Adjusted Ventilatory Assist (NAVA) controls MV through an esophageal reading of diaphragm electrical activity via a nasogastric tube mounted with electrode rings. NAVA has been shown to decrease asynchrony in comparison to pressure support ventilation (PSV). The objective of this study was to conduct a health economic evaluation of NAVA compared with PSV. We developed a model based on an indirect link between improved synchrony with NAVA versus PSV and fewer days spent on MV in synchronous patients. Unit costs for MV were obtained from the Swedish intensive care unit register, and used in the model along with NAVA-specific costs. The importance of each parameter (proportion of asynchronous patients, costs, and average MV duration) for the overall results was evaluated through sensitivity analyses. Base case results showed that 21% of patients ventilated with NAVA were asynchronous versus 52% of patients receiving PSV. This equals an absolute difference of 31% and an average of 1.7 days less on MV and a total cost saving of US$7886 (including NAVA catheter costs). A breakeven analysis suggested that NAVA was cost effective compared with PSV given an absolute difference in the proportion of asynchronous patients greater than 2.5% (49.5% versus 52% asynchronous patients with NAVA and PSV, respectively). The base case results were stable to changes in parameters, such as difference in asynchrony, duration of ventilation and daily intensive care unit costs. This study showed economically favorable results for NAVA versus PSV. Our results show that only a minor decrease in the proportion of asynchronous patients with NAVA is needed for investments to pay off and generate savings. Future studies need to confirm this result by directly relating improved synchrony to the number of days on MV. © The Author(s), 2015.

  3. SU-F-J-95: Impact of Shape Complexity On the Accuracy of Gradient-Based PET Volume Delineation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dance, M; Wu, G; Gao, Y

    2016-06-15

    Purpose: Explore correlation of tumor complexity shape with PET target volume accuracy when delineated with gradient-based segmentation tool. Methods: A total of 24 clinically realistic digital PET Monte Carlo (MC) phantoms of NSCLC were used in the study. The phantom simulated 29 thoracic lesions (lung primary and mediastinal lymph nodes) of varying size, shape, location, and {sup 18}F-FDG activity. A program was developed to calculate a curvature vector along the outline and the standard deviation of this vector was used as a metric to quantify a shape’s “complexity score”. This complexity score was calculated for standard geometric shapes and MC-generatedmore » target volumes in PET phantom images. All lesions were contoured using a commercially available gradient-based segmentation tool and the differences in volume from the MC-generated volumes were calculated as the measure of the accuracy of segmentation. Results: The average absolute percent difference in volumes between the MC-volumes and gradient-based volumes was 11% (0.4%–48.4%). The complexity score showed strong correlation with standard geometric shapes. However, no relationship was found between the complexity score and the accuracy of segmentation by gradient-based tool on MC simulated tumors (R{sup 2} = 0.156). When the lesions were grouped into primary lung lesions and mediastinal/mediastinal adjacent lesions, the average absolute percent difference in volumes were 6% and 29%, respectively. The former group is more isolated and the latter is more surround by tissues with relatively high SUV background. Conclusion: The complexity shape of NSCLC lesions has little effect on the accuracy of the gradient-based segmentation method and thus is not a good predictor of uncertainty in target volume delineation. Location of lesion within a relatively high SUV background may play a more significant role in the accuracy of gradient-based segmentation.« less

  4. Three Averaging Techniques for Reduction of Antenna Temperature Variance Measured by a Dicke Mode, C-Band Radiometer

    NASA Technical Reports Server (NTRS)

    Mackenzie, Anne I.; Lawrence, Roland W.

    2000-01-01

    As new radiometer technologies provide the possibility of greatly improved spatial resolution, their performance must also be evaluated in terms of expected sensitivity and absolute accuracy. As aperture size increases, the sensitivity of a Dicke mode radiometer can be maintained or improved by application of any or all of three digital averaging techniques: antenna data averaging with a greater than 50% antenna duty cycle, reference data averaging, and gain averaging. An experimental, noise-injection, benchtop radiometer at C-band showed a 68.5% reduction in Delta-T after all three averaging methods had been applied simultaneously. For any one antenna integration time, the optimum 34.8% reduction in Delta-T was realized by using an 83.3% antenna/reference duty cycle.

  5. Validation of two-dimensional and three-dimensional measurements of subpleural alveolar size parameters by optical coherence tomography

    PubMed Central

    Warger, William C.; Hostens, Jeroen; Namati, Eman; Birngruber, Reginald; Bouma, Brett E.; Tearney, Guillermo J.

    2012-01-01

    Abstract. Optical coherence tomography (OCT) has been increasingly used for imaging pulmonary alveoli. Only a few studies, however, have quantified individual alveolar areas, and the validity of alveolar volumes represented within OCT images has not been shown. To validate quantitative measurements of alveoli from OCT images, we compared the cross-sectional area, perimeter, volume, and surface area of matched subpleural alveoli from microcomputed tomography (micro-CT) and OCT images of fixed air-filled swine samples. The relative change in size between different alveoli was extremely well correlated (r>0.9, P<0.0001), but OCT images underestimated absolute sizes compared to micro-CT by 27% (area), 7% (perimeter), 46% (volume), and 25% (surface area) on average. We hypothesized that the differences resulted from refraction at the tissue–air interfaces and developed a ray-tracing model that approximates the reconstructed alveolar size within OCT images. Using this model and OCT measurements of the refractive index for lung tissue (1.41 for fresh, 1.53 for fixed), we derived equations to obtain absolute size measurements of superellipse and circular alveoli with the use of predictive correction factors. These methods and results should enable the quantification of alveolar sizes from OCT images in vivo. PMID:23235834

  6. Validation of two-dimensional and three-dimensional measurements of subpleural alveolar size parameters by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Unglert, Carolin I.; Warger, William C.; Hostens, Jeroen; Namati, Eman; Birngruber, Reginald; Bouma, Brett E.; Tearney, Guillermo J.

    2012-12-01

    Optical coherence tomography (OCT) has been increasingly used for imaging pulmonary alveoli. Only a few studies, however, have quantified individual alveolar areas, and the validity of alveolar volumes represented within OCT images has not been shown. To validate quantitative measurements of alveoli from OCT images, we compared the cross-sectional area, perimeter, volume, and surface area of matched subpleural alveoli from microcomputed tomography (micro-CT) and OCT images of fixed air-filled swine samples. The relative change in size between different alveoli was extremely well correlated (r>0.9, P<0.0001), but OCT images underestimated absolute sizes compared to micro-CT by 27% (area), 7% (perimeter), 46% (volume), and 25% (surface area) on average. We hypothesized that the differences resulted from refraction at the tissue-air interfaces and developed a ray-tracing model that approximates the reconstructed alveolar size within OCT images. Using this model and OCT measurements of the refractive index for lung tissue (1.41 for fresh, 1.53 for fixed), we derived equations to obtain absolute size measurements of superellipse and circular alveoli with the use of predictive correction factors. These methods and results should enable the quantification of alveolar sizes from OCT images in vivo.

  7. Comparison of 3D bone models of the knee joint derived from CT and 3T MR imaging.

    PubMed

    Neubert, Aleš; Wilson, Katharine J; Engstrom, Craig; Surowiec, Rachel K; Paproki, Anthony; Johnson, Nicholas; Crozier, Stuart; Fripp, Jurgen; Ho, Charles P

    2017-08-01

    To examine whether magnetic resonance (MR) imaging can offer a viable alternative to computed tomography (CT) based 3D bone modeling. CT and MR (SPACE, TrueFISP, VIBE) images were acquired from the left knee joint of a fresh-frozen cadaver. The distal femur, proximal tibia, proximal fibula and patella were manually segmented from the MR and CT examinations. The MR bone models obtained from manual segmentations of all three sequences were compared to CT models using a similarity measure based on absolute mesh differences. The average absolute distance between the CT and the various MR-based bone models were all below 1mm across all bones. The VIBE sequence provided the best agreement with the CT model, followed by the SPACE, then the TrueFISP data. The most notable difference was for the proximal tibia (VIBE 0.45mm, SPACE 0.82mm, TrueFISP 0.83mm). The study indicates that 3D MR bone models may offer a feasible alternative to traditional CT-based modeling. A single radiological examination using the MR imaging would allow simultaneous assessment of both bones and soft-tissues, providing anatomically comprehensive joint models for clinical evaluation, without the ionizing radiation of CT imaging. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Evaluation of Greenland near surface air temperature datasets

    DOE PAGES

    Reeves Eyre, J. E. Jack; Zeng, Xubin

    2017-07-05

    Near-surface air temperature (SAT) over Greenland has important effects on mass balance of the ice sheet, but it is unclear which SAT datasets are reliable in the region. Here extensive in situ SAT measurements ( ∼  1400 station-years) are used to assess monthly mean SAT from seven global reanalysis datasets, five gridded SAT analyses, one satellite retrieval and three dynamically downscaled reanalyses. Strengths and weaknesses of these products are identified, and their biases are found to vary by season and glaciological regime. MERRA2 reanalysis overall performs best with mean absolute error less than 2 °C in all months. Ice sheet-average annual mean SAT frommore » different datasets are highly correlated in recent decades, but their 1901–2000 trends differ even in sign. Compared with the MERRA2 climatology combined with gridded SAT analysis anomalies, thirty-one earth system model historical runs from the CMIP5 archive reach  ∼  5 °C for the 1901–2000 average bias and have opposite trends for a number of sub-periods.« less

  9. Evaluation of Greenland near surface air temperature datasets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reeves Eyre, J. E. Jack; Zeng, Xubin

    Near-surface air temperature (SAT) over Greenland has important effects on mass balance of the ice sheet, but it is unclear which SAT datasets are reliable in the region. Here extensive in situ SAT measurements ( ∼  1400 station-years) are used to assess monthly mean SAT from seven global reanalysis datasets, five gridded SAT analyses, one satellite retrieval and three dynamically downscaled reanalyses. Strengths and weaknesses of these products are identified, and their biases are found to vary by season and glaciological regime. MERRA2 reanalysis overall performs best with mean absolute error less than 2 °C in all months. Ice sheet-average annual mean SAT frommore » different datasets are highly correlated in recent decades, but their 1901–2000 trends differ even in sign. Compared with the MERRA2 climatology combined with gridded SAT analysis anomalies, thirty-one earth system model historical runs from the CMIP5 archive reach  ∼  5 °C for the 1901–2000 average bias and have opposite trends for a number of sub-periods.« less

  10. STOCK Market Differences in Correlation-Based Weighted Network

    NASA Astrophysics Data System (ADS)

    Youn, Janghyuk; Lee, Junghoon; Chang, Woojin

    We examined the sector dynamics of Korean stock market in relation to the market volatility. The daily price data of 360 stocks for 5019 trading days (from January, 1990 to August, 2008) in Korean stock market are used. We performed the weighted network analysis and employed four measures: the average, the variance, the intensity, and the coherence of network weights (absolute values of stock return correlations) to investigate the network structure of Korean stock market. We performed regression analysis using the four measures in the seven major industry sectors and the market (seven sectors combined). We found that the average, the intensity, and the coherence of sector (subnetwork) weights increase as market becomes volatile. Except for the "Financials" sector, the variance of sector weights also grows as market volatility increases. Based on the four measures, we can categorize "Financials," "Information Technology" and "Industrials" sectors into one group, and "Materials" and "Consumer Discretionary" sectors into another group. We investigated the distributions of intrasector and intersector weights for each sector and found the differences in "Financials" sector are most distinct.

  11. Assessment of maxillary position. Implant vs cephalometric methods.

    PubMed

    Verayannont, Panisha; Hägg, Urban; Wong, Ricky W K; McGrath, Colman; Yeung, Shadow

    2010-09-01

    To compare changes in maxillary position assessed from a maxillary implant and three cephalometric methods based on linear measurements. Series of tracings of the maxilla obtained around puberty from an implant study were analyzed. The displacement of the implant was used to determine the direction and amount of "actual" maxillary growth. Displacement of point A was measured according to three cephalometric methods. The values obtained from absolute, horizontal, and vertical displacement of point A by three cephalometric methods and by the implant method were compared. Results showed that estimation of displacement of the maxilla by three cephalometric methods (point A) was significantly larger than that of the implant method in all directions. The average difference in the horizontal plane was 0.7 mm, 1.2 mm, and 1.6 mm, respectively; the average difference in the vertical plane was 2.2 mm, 2.5 mm, and 3.6 mm, respectively. Estimations of changes in maxillary position by the implant method and by cephalometric methods were not proportional. All three cephalometric methods overestimated changes in the position of the maxilla.

  12. Inter-comparison of precipitable water among reanalyses and its effect on downscaling in the tropics

    NASA Astrophysics Data System (ADS)

    Takahashi, H. G.; Fujita, M.; Hara, M.

    2012-12-01

    This paper compared precipitable water (PW) among four major reanalyses. In addition, we also investigated the effect of the boundary conditions on downscaling in the tropics, using a regional climate model. The spatial pattern of PW in the reanalyses agreed closely with observations. However, the absolute amounts of PW in some reanalyses were very small compared to observations. The discrepancies of the 12-year mean PW in July over the Southeast Asian monsoon region exceeded the inter-annual standard deviation of the PW. There was also a discrepancy in tropical PWs throughout the year, an indication that the problem is not regional, but global. The downscaling experiments were conducted, which were forced by the different four reanalyses. The atmospheric circulation, including monsoon westerlies and various disturbances, was very small among the reanalyses. However, simulated precipitation was only 60 % of observed precipitation, although the dry bias in the boundary conditions was only 6 %. This result indicates that dry bias has large effects on precipitation in downscaling over the tropics. This suggests that a simulated regional climate downscaled from ensemble-mean boundary conditions is quite different from an ensemble-mean regional climate averaged over the several regional ones downscaled from boundary conditions of the ensemble members in the tropics. Downscaled models can provide realistic simulations of regional tropical climates only if the boundary conditions include realistic absolute amounts of PW. Use of boundary conditions that include realistic absolute amounts of PW in downscaling in the tropics is imperative at the present time. This work was partly supported by the Global Environment Research Fund (RFa-1101) of the Ministry of the Environment, Japan.

  13. Simulated building energy demand biases resulting from the use of representative weather stations

    DOE PAGES

    Burleyson, Casey D.; Voisin, Nathalie; Taylor, Z. Todd; ...

    2017-11-06

    Numerical building models are typically forced with weather data from a limited number of “representative cities” or weather stations representing different climate regions. The use of representative weather stations reduces computational costs, but often fails to capture spatial heterogeneity in weather that may be important for simulations aimed at understanding how building stocks respond to a changing climate. Here, we quantify the potential reduction in temperature and load biases from using an increasing number of weather stations over the western U.S. Our novel approach is based on deriving temperature and load time series using incrementally more weather stations, ranging frommore » 8 to roughly 150, to evaluate the ability to capture weather patterns across different seasons. Using 8 stations across the western U.S., one from each IECC climate zone, results in an average absolute summertime temperature bias of ~4.0 °C with respect to a high-resolution gridded dataset. The mean absolute bias drops to ~1.5 °C using all available weather stations. Temperature biases of this magnitude could translate to absolute summertime mean simulated load biases as high as 13.5%. Increasing the size of the domain over which biases are calculated reduces their magnitude as positive and negative biases may cancel out. Using 8 representative weather stations can lead to a 20–40% bias of peak building loads during both summer and winter, a significant error for capacity expansion planners who may use these types of simulations. Using weather stations close to population centers reduces both mean and peak load biases. Our approach could be used by others designing aggregate building simulations to understand the sensitivity to their choice of weather stations used to drive the models.« less

  14. Feasibility study on dosimetry verification of volumetric-modulated arc therapy-based total marrow irradiation.

    PubMed

    Liang, Yun; Kim, Gwe-Ya; Pawlicki, Todd; Mundt, Arno J; Mell, Loren K

    2013-03-04

    The purpose of this study was to develop dosimetry verification procedures for volumetric-modulated arc therapy (VMAT)-based total marrow irradiation (TMI). The VMAT based TMI plans were generated for three patients: one child and two adults. The planning target volume (PTV) was defined as bony skeleton, from head to mid-femur, with a 3 mm margin. The plan strategy similar to published studies was adopted. The PTV was divided into head and neck, chest, and pelvic regions, with separate plans each of which is composed of 2-3 arcs/fields. Multiple isocenters were evenly distributed along the patient's axial direction. The focus of this study is to establish a dosimetry quality assurance procedure involving both two-dimensional (2D) and three-dimensional (3D) volumetric verifications, which is desirable for a large PTV treated with multiple isocenters. The 2D dose verification was performed with film for gamma evaluation and absolute point dose was measured with ion chamber, with attention to the junction between neighboring plans regarding hot/cold spots. The 3D volumetric dose verification used commercial dose reconstruction software to reconstruct dose from electronic portal imaging devices (EPID) images. The gamma evaluation criteria in both 2D and 3D verification were 5% absolute point dose difference and 3 mm of distance to agreement. With film dosimetry, the overall average gamma passing rate was 98.2% and absolute dose difference was 3.9% in junction areas among the test patients; with volumetric portal dosimetry, the corresponding numbers were 90.7% and 2.4%. A dosimetry verification procedure involving both 2D and 3D was developed for VMAT-based TMI. The initial results are encouraging and warrant further investigation in clinical trials.

  15. The application of multilevel modeling in the analysis of longitudinal periodontal data--part I: absolute levels of disease.

    PubMed

    Tu, Yu-Kang; Gilthorpe, Mark S; Griffiths, Gareth S; Maddick, Ian H; Eaton, Kenneth A; Johnson, Newell W

    2004-01-01

    Statistical analyses of periodontal data that average site measurements to subject mean values are unable to explore the site-specific nature of periodontal diseases. Multilevel modeling (MLM) overcomes this, taking hierarchical structure into account. MLM was used to investigate longitudinal relationships between the outcomes of lifetime cumulative attachment loss (LCAL) and probing depth (PD) in relation to potential risk factors for periodontal disease progression. One hundred males (mean age 17 years) received a comprehensive periodontal examination at baseline and at 12 and 30 months. The resulting data were analyzed in two stages. In stage one (reported here), the absolute levels of disease were analyzed in relation to potential risk factors; in stage two (reported in a second paper), changes in disease patterns over time were analyzed in relation to the same risk factors. Each approach yielded substantially different insights. For absolute levels of disease, subject-level risk factors (covariates) had limited prediction for LCAL/PD throughout the 30-month observation period. Tooth position demonstrated a near linear relationship for both outcomes, with disease increasing from anterior to posterior teeth. Sites with subgingival calculus and bleeding on probing demonstrated more LCAL and PD, and supragingival calculus had an apparently protective effect. Covariates had more "explanatory power" for the variation in PD than for the variation in LCAL, suggesting that LCAL and PD might be generally associated with a different profile of covariates. This study provides, for a relatively young cohort, considerable insights into the factors associated with early-life periodontal disease and its progression at all levels of the natural hierarchy of sites within teeth within subjects.

  16. Simulated building energy demand biases resulting from the use of representative weather stations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burleyson, Casey D.; Voisin, Nathalie; Taylor, Z. Todd

    Numerical building models are typically forced with weather data from a limited number of “representative cities” or weather stations representing different climate regions. The use of representative weather stations reduces computational costs, but often fails to capture spatial heterogeneity in weather that may be important for simulations aimed at understanding how building stocks respond to a changing climate. Here, we quantify the potential reduction in temperature and load biases from using an increasing number of weather stations over the western U.S. Our novel approach is based on deriving temperature and load time series using incrementally more weather stations, ranging frommore » 8 to roughly 150, to evaluate the ability to capture weather patterns across different seasons. Using 8 stations across the western U.S., one from each IECC climate zone, results in an average absolute summertime temperature bias of ~4.0 °C with respect to a high-resolution gridded dataset. The mean absolute bias drops to ~1.5 °C using all available weather stations. Temperature biases of this magnitude could translate to absolute summertime mean simulated load biases as high as 13.5%. Increasing the size of the domain over which biases are calculated reduces their magnitude as positive and negative biases may cancel out. Using 8 representative weather stations can lead to a 20–40% bias of peak building loads during both summer and winter, a significant error for capacity expansion planners who may use these types of simulations. Using weather stations close to population centers reduces both mean and peak load biases. Our approach could be used by others designing aggregate building simulations to understand the sensitivity to their choice of weather stations used to drive the models.« less

  17. Simulated building energy demand biases resulting from the use of representative weather stations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burleyson, Casey D.; Voisin, Nathalie; Taylor, Z. Todd

    Numerical building models are typically forced with weather data from a limited number of “representative cities” or weather stations representing different climate regions. The use of representative weather stations reduces computational costs, but often fails to capture spatial heterogeneity in weather that may be important for simulations aimed at understanding how building stocks respond to a changing climate. We quantify the potential reduction in bias from using an increasing number of weather stations over the western U.S. The approach is based on deriving temperature and load time series using incrementally more weather stations, ranging from 8 to roughly 150, tomore » capture weather across different seasons. Using 8 stations, one from each climate zone, across the western U.S. results in an average absolute summertime temperature bias of 7.2°F with respect to a spatially-resolved gridded dataset. The mean absolute bias drops to 2.8°F using all available weather stations. Temperature biases of this magnitude could translate to absolute summertime mean simulated load biases as high as 13.8%, a significant error for capacity expansion planners who may use these types of simulations. Increasing the size of the domain over which biases are calculated reduces their magnitude as positive and negative biases may cancel out. Using 8 representative weather stations can lead to a 20-40% overestimation of peak building loads during both summer and winter. Using weather stations close to population centers reduces both mean and peak load biases. This approach could be used by others designing aggregate building simulations to understand the sensitivity to their choice of weather stations used to drive the models.« less

  18. Patient characteristics and factors associated with inter-arm difference of blood pressure measurements in a general population in Ohasama, Japan.

    PubMed

    Kimura, Atsushi; Hashimoto, Junichiro; Watabe, Daisuke; Takahashi, Hisaki; Ohkubo, Takayoshi; Kikuya, Masahiro; Imai, Yutaka

    2004-12-01

    To assess whether there is a natural difference in blood pressure (BP) measurements between the right and left arms, and to identify what factors are associated with this difference in a general population. The study subjects were 1090 individuals who participated in a medical check-up in Ohasama, Japan. The BP was measured simultaneously in both arms, using an automated device. The inter-arm BP difference was expressed as the relative difference [right-arm BP (R) minus left-arm BP (L): R - L] and the absolute difference (|R - L|). The relationship between inter-arm difference and various factors was analyzed using univariate analysis. The characteristics of subjects in whom the absolute systolic BP (SBP) difference was greater than 10 mmHg were analyzed using multivariate logistic analysis. The relative differences in SBP and diastolic BP (DBP) were -0.6 +/- 6.6 (mean +/- SD) and 1.1 +/- 4.7 mmHg, while the absolute differences were 4.9 +/- 4.4 and 3.7 +/- 3.0 mmHg. The absolute SBP difference was found to correlate significantly with age, body mass index, ankle-brachial index (ABI), and hypertension. Subjects with hypertension, hypercholesterolemia, obesity, elevated hemoglobin A1c (HbA1c) and low ABI had a significant and independent increase in the risk of an absolute SBP difference greater than 10 mmHg. The results suggest that there is considerable difference in the measured BP in the right and left arms and that large differences in the absolute SBP are associated with risk factors for arteriosclerosis such as hypertension, hypercholesterolemia, obesity, metabolic abnormalities and low ABI.

  19. The interactive role of income (material position) and income rank (psychosocial position) in psychological distress: a 9-year longitudinal study of 30,000 UK parents.

    PubMed

    Garratt, Elisabeth A; Chandola, Tarani; Purdam, Kingsley; Wood, Alex M

    2016-10-01

    Parents face an increased risk of psychological distress compared with adults without children, and families with children also have lower average household incomes. Past research suggests that absolute income (material position) and income status (psychosocial position) influence psychological distress, but their combined effects on changes in psychological distress have not been examined. Whether absolute income interacts with income status to influence psychological distress are also key questions. We used fixed-effects panel models to examine longitudinal associations between psychological distress (measured on the Kessler scale) and absolute income, distance from the regional mean income, and regional income rank (a proxy for status) using data from 29,107 parents included in the UK Millennium Cohort Study (2003-2012). Psychological distress was determined by an interaction between absolute income and income rank: higher absolute income was associated with lower psychological distress across the income spectrum, while the benefits of higher income rank were evident only in the highest income parents. Parents' psychological distress was, therefore, determined by a combination of income-related material and psychosocial factors. Both material and psychosocial factors contribute to well-being. Higher absolute incomes were associated with lower psychological distress across the income spectrum, demonstrating the importance of material factors. Conversely, income status was associated with psychological distress only at higher absolute incomes, suggesting that psychosocial factors are more relevant to distress in more advantaged, higher income parents. Clinical interventions could, therefore, consider both the material and psychosocial impacts of income on psychological distress.

  20. Water quality management using statistical analysis and time-series prediction model

    NASA Astrophysics Data System (ADS)

    Parmar, Kulwinder Singh; Bhardwaj, Rashmi

    2014-12-01

    This paper deals with water quality management using statistical analysis and time-series prediction model. The monthly variation of water quality standards has been used to compare statistical mean, median, mode, standard deviation, kurtosis, skewness, coefficient of variation at Yamuna River. Model validated using R-squared, root mean square error, mean absolute percentage error, maximum absolute percentage error, mean absolute error, maximum absolute error, normalized Bayesian information criterion, Ljung-Box analysis, predicted value and confidence limits. Using auto regressive integrated moving average model, future water quality parameters values have been estimated. It is observed that predictive model is useful at 95 % confidence limits and curve is platykurtic for potential of hydrogen (pH), free ammonia, total Kjeldahl nitrogen, dissolved oxygen, water temperature (WT); leptokurtic for chemical oxygen demand, biochemical oxygen demand. Also, it is observed that predicted series is close to the original series which provides a perfect fit. All parameters except pH and WT cross the prescribed limits of the World Health Organization /United States Environmental Protection Agency, and thus water is not fit for drinking, agriculture and industrial use.

  1. Neural Sensitivity to Absolute and Relative Anticipated Reward in Adolescents

    PubMed Central

    Vaidya, Jatin G.; Knutson, Brian; O'Leary, Daniel S.; Block, Robert I.; Magnotta, Vincent

    2013-01-01

    Adolescence is associated with a dramatic increase in risky and impulsive behaviors that have been attributed to developmental differences in neural processing of rewards. In the present study, we sought to identify age differences in anticipation of absolute and relative rewards. To do so, we modified a commonly used monetary incentive delay (MID) task in order to examine brain activity to relative anticipated reward value (neural sensitivity to the value of a reward as a function of other available rewards). This design also made it possible to examine developmental differences in brain activation to absolute anticipated reward magnitude (the degree to which neural activity increases with increasing reward magnitude). While undergoing fMRI, 18 adolescents and 18 adult participants were presented with cues associated with different reward magnitudes. After the cue, participants responded to a target to win money on that trial. Presentation of cues was blocked such that two reward cues associated with $.20, $1.00, or $5.00 were in play on a given block. Thus, the relative value of the $1.00 reward varied depending on whether it was paired with a smaller or larger reward. Reflecting age differences in neural responses to relative anticipated reward (i.e., reference dependent processing), adults, but not adolescents, demonstrated greater activity to a $1 reward when it was the larger of the two available rewards. Adults also demonstrated a more linear increase in ventral striatal activity as a function of increasing absolute reward magnitude compared to adolescents. Additionally, reduced ventral striatal sensitivity to absolute anticipated reward (i.e., the difference in activity to medium versus small rewards) correlated with higher levels of trait Impulsivity. Thus, ventral striatal activity in anticipation of absolute and relative rewards develops with age. Absolute reward processing is also linked to individual differences in Impulsivity. PMID:23544046

  2. Effect of Oblique Electromagnetic Ion Cyclotron Waves on Relativistic Electron Scattering: CRRES Based Calculation

    NASA Technical Reports Server (NTRS)

    Gamayunov, K. V.; Khazanov, G. V.

    2007-01-01

    We consider the effect of oblique EMIC waves on relativistic electron scattering in the outer radiation belt using simultaneous observations of plasma and wave parameters from CRRES. The main findings can be s ummarized as follows: 1. In 1comparison with field-aligned waves, int ermediate and highly oblique distributions decrease the range of pitc h-angles subject to diffusion, and reduce the local scattering rate b y an order of magnitude at pitch-angles where the principle absolute value of n = 1 resonances operate. Oblique waves allow the absolute va lue of n > 1 resonances to operate, extending the range of local pitc h-angle diffusion down to the loss cone, and increasing the diffusion at lower pitch angles by orders of magnitude; 2. The local diffusion coefficients derived from CRRES data are qualitatively similar to the local results obtained for prescribed plasma/wave parameters. Conseq uently, it is likely that the bounce-averaged diffusion coefficients, if estimated from concurrent data, will exhibit the dependencies similar to those we found for model calculations; 3. In comparison with f ield-aligned waves, intermediate and highly oblique waves decrease th e bounce-averaged scattering rate near the edge of the equatorial lo ss cone by orders of magnitude if the electron energy does not excee d a threshold (approximately equal to 2 - 5 MeV) depending on specified plasma and/or wave parameters; 4. For greater electron energies_ ob lique waves operating the absolute value of n > 1 resonances are more effective and provide the same bounce_averaged diffusion rate near the loss cone as fiel_aligned waves do.

  3. Cell wall microstructure, pore size distribution and absolute density of hemp shiv

    PubMed Central

    Lawrence, M.; Ansell, M. P.; Hussain, A.

    2018-01-01

    This paper, for the first time, fully characterizes the intrinsic physical parameters of hemp shiv including cell wall microstructure, pore size distribution and absolute density. Scanning electron microscopy revealed microstructural features similar to hardwoods. Confocal microscopy revealed three major layers in the cell wall: middle lamella, primary cell wall and secondary cell wall. Computed tomography improved the visualization of pore shape and pore connectivity in three dimensions. Mercury intrusion porosimetry (MIP) showed that the average accessible porosity was 76.67 ± 2.03% and pore size classes could be distinguished into micropores (3–10 nm) and macropores (0.1–1 µm and 20–80 µm). The absolute density was evaluated by helium pycnometry, MIP and Archimedes' methods. The results show that these methods can lead to misinterpretation of absolute density. The MIP method showed a realistic absolute density (1.45 g cm−3) consistent with the density of the known constituents, including lignin, cellulose and hemi-cellulose. However, helium pycnometry and Archimedes’ methods gave falsely low values owing to 10% of the volume being inaccessible pores, which require sample pretreatment in order to be filled by liquid or gas. This indicates that the determination of the cell wall density is strongly dependent on sample geometry and preparation. PMID:29765652

  4. Cell wall microstructure, pore size distribution and absolute density of hemp shiv

    NASA Astrophysics Data System (ADS)

    Jiang, Y.; Lawrence, M.; Ansell, M. P.; Hussain, A.

    2018-04-01

    This paper, for the first time, fully characterizes the intrinsic physical parameters of hemp shiv including cell wall microstructure, pore size distribution and absolute density. Scanning electron microscopy revealed microstructural features similar to hardwoods. Confocal microscopy revealed three major layers in the cell wall: middle lamella, primary cell wall and secondary cell wall. Computed tomography improved the visualization of pore shape and pore connectivity in three dimensions. Mercury intrusion porosimetry (MIP) showed that the average accessible porosity was 76.67 ± 2.03% and pore size classes could be distinguished into micropores (3-10 nm) and macropores (0.1-1 µm and 20-80 µm). The absolute density was evaluated by helium pycnometry, MIP and Archimedes' methods. The results show that these methods can lead to misinterpretation of absolute density. The MIP method showed a realistic absolute density (1.45 g cm-3) consistent with the density of the known constituents, including lignin, cellulose and hemi-cellulose. However, helium pycnometry and Archimedes' methods gave falsely low values owing to 10% of the volume being inaccessible pores, which require sample pretreatment in order to be filled by liquid or gas. This indicates that the determination of the cell wall density is strongly dependent on sample geometry and preparation.

  5. Five-Kilometers Time Trial: Preliminary Validation of a Short Test for Cycling Performance Evaluation.

    PubMed

    Dantas, Jose Luiz; Pereira, Gleber; Nakamura, Fabio Yuzo

    2015-09-01

    The five-kilometer time trial (TT5km) has been used to assess aerobic endurance performance without further investigation of its validity. This study aimed to perform a preliminary validation of the TT5km to rank well-trained cyclists based on aerobic endurance fitness and assess changes of the aerobic endurance performance. After the incremental test, 20 cyclists (age = 31.3 ± 7.9 years; body mass index = 22.7 ± 1.5 kg/m(2); maximal aerobic power = 360.5 ± 49.5 W) performed the TT5km twice, collecting performance (time to complete, absolute and relative power output, average speed) and physiological responses (heart rate and electromyography activity). The validation criteria were pacing strategy, absolute and relative reliability, validity, and sensitivity. Sensitivity index was obtained from the ratio between the smallest worthwhile change and typical error. The TT5km showed high absolute (coefficient of variation < 3%) and relative (intraclass coefficient correlation > 0.95) reliability of performance variables, whereas it presented low reliability of physiological responses. The TT5km performance variables were highly correlated with the aerobic endurance indices obtained from incremental test (r > 0.70). These variables showed adequate sensitivity index (> 1). TT5km is a valid test to rank the aerobic endurance fitness of well-trained cyclists and to differentiate changes on aerobic endurance performance. Coaches can detect performance changes through either absolute (± 17.7 W) or relative power output (± 0.3 W.kg(-1)), the time to complete the test (± 13.4 s) and the average speed (± 1.0 km.h(-1)). Furthermore, TT5km performance can also be used to rank the athletes according to their aerobic endurance fitness.

  6. The Berg Balance Scale has high intra- and inter-rater reliability but absolute reliability varies across the scale: a systematic review.

    PubMed

    Downs, Stephen; Marquez, Jodie; Chiarelli, Pauline

    2013-06-01

    What is the intra-rater and inter-rater relative reliability of the Berg Balance Scale? What is the absolute reliability of the Berg Balance Scale? Does the absolute reliability of the Berg Balance Scale vary across the scale? Systematic review with meta-analysis of reliability studies. Any clinical population that has undergone assessment with the Berg Balance Scale. Relative intra-rater reliability, relative inter-rater reliability, and absolute reliability. Eleven studies involving 668 participants were included in the review. The relative intrarater reliability of the Berg Balance Scale was high, with a pooled estimate of 0.98 (95% CI 0.97 to 0.99). Relative inter-rater reliability was also high, with a pooled estimate of 0.97 (95% CI 0.96 to 0.98). A ceiling effect of the Berg Balance Scale was evident for some participants. In the analysis of absolute reliability, all of the relevant studies had an average score of 20 or above on the 0 to 56 point Berg Balance Scale. The absolute reliability across this part of the scale, as measured by the minimal detectable change with 95% confidence, varied between 2.8 points and 6.6 points. The Berg Balance Scale has a higher absolute reliability when close to 56 points due to the ceiling effect. We identified no data that estimated the absolute reliability of the Berg Balance Scale among participants with a mean score below 20 out of 56. The Berg Balance Scale has acceptable reliability, although it might not detect modest, clinically important changes in balance in individual subjects. The review was only able to comment on the absolute reliability of the Berg Balance Scale among people with moderately poor to normal balance. Copyright © 2013 Australian Physiotherapy Association. Published by .. All rights reserved.

  7. Constraint on Absolute Accuracy of Metacomprehension Assessments: The Anchoring and Adjustment Model vs. the Standards Model

    ERIC Educational Resources Information Center

    Kwon, Heekyung

    2011-01-01

    The objective of this study is to provide a systematic account of three typical phenomena surrounding absolute accuracy of metacomprehension assessments: (1) the absolute accuracy of predictions is typically quite low; (2) there exist individual differences in absolute accuracy of predictions as a function of reading skill; and (3) postdictions…

  8. Discrete distributed strain sensing of intelligent structures

    NASA Technical Reports Server (NTRS)

    Anderson, Mark S.; Crawley, Edward F.

    1992-01-01

    Techniques are developed for the design of discrete highly distributed sensor systems for use in intelligent structures. First the functional requirements for such a system are presented. Discrete spatially averaging strain sensors are then identified as satisfying the functional requirements. A variety of spatial weightings for spatially averaging sensors are examined, and their wave number characteristics are determined. Preferable spatial weightings are identified. Several numerical integration rules used to integrate such sensors in order to determine the global deflection of the structure are discussed. A numerical simulation is conducted using point and rectangular sensors mounted on a cantilevered beam under static loading. Gage factor and sensor position uncertainties are incorporated to assess the absolute error and standard deviation of the error in the estimated tip displacement found by numerically integrating the sensor outputs. An experiment is carried out using a statically loaded cantilevered beam with five point sensors. It is found that in most cases the actual experimental error is within one standard deviation of the absolute error as found in the numerical simulation.

  9. Hydrothermal extremes at the South-West Pribaikalie during the current climate changes

    NASA Astrophysics Data System (ADS)

    Voropay, Nadezhda

    2017-04-01

    Climatic extremes of air temperature and precipitation were analyzed for the Tunka Intermountain Depression (South-West Pribaikalie, Buryatia, Russian Federation). Intermountain depressions occupy a quarter of the territory of the Baikal region. The specific climatic conditions in the depressions are formed due to the geographic location and the influence of latitudinal zonation and altitudinal gradients. Air temperature and precipitation data records from at weather stations for the period 1940-2015 were analyzed. Long-term average annual temperature is negative and varies from -0.8 °C to -2.4 °C. Air temperature absolute minimum is -48 °C, absolute maximum is +36 °C. The long-term average annual precipitation is 370-480 mm, but in some years annual precipitation reach 760 mm. The summer months have about 70% of the total annual precipitation, in July and August the sum may reach 340 mm. Maximum daily sum of rainfalls is 80 mm. The contribution of the global and regional circulation characteristics into the variability of regional climatic characteristics was estimated.

  10. A new method to estimate average hourly global solar radiation on the horizontal surface

    NASA Astrophysics Data System (ADS)

    Pandey, Pramod K.; Soupir, Michelle L.

    2012-10-01

    A new model, Global Solar Radiation on Horizontal Surface (GSRHS), was developed to estimate the average hourly global solar radiation on the horizontal surfaces (Gh). The GSRHS model uses the transmission function (Tf,ij), which was developed to control hourly global solar radiation, for predicting solar radiation. The inputs of the model were: hour of day, day (Julian) of year, optimized parameter values, solar constant (H0), latitude, and longitude of the location of interest. The parameter values used in the model were optimized at a location (Albuquerque, NM), and these values were applied into the model for predicting average hourly global solar radiations at four different locations (Austin, TX; El Paso, TX; Desert Rock, NV; Seattle, WA) of the United States. The model performance was assessed using correlation coefficient (r), Mean Absolute Bias Error (MABE), Root Mean Square Error (RMSE), and coefficient of determinations (R2). The sensitivities of parameter to prediction were estimated. Results show that the model performed very well. The correlation coefficients (r) range from 0.96 to 0.99, while coefficients of determination (R2) range from 0.92 to 0.98. For daily and monthly prediction, error percentages (i.e. MABE and RMSE) were less than 20%. The approach we proposed here can be potentially useful for predicting average hourly global solar radiation on the horizontal surface for different locations, with the use of readily available data (i.e. latitude and longitude of the location) as inputs.

  11. Effects of extended-release niacin with laropiprant in high-risk patients.

    PubMed

    Landray, Martin J; Haynes, Richard; Hopewell, Jemma C; Parish, Sarah; Aung, Theingi; Tomson, Joseph; Wallendszus, Karl; Craig, Martin; Jiang, Lixin; Collins, Rory; Armitage, Jane

    2014-07-17

    Patients with evidence of vascular disease are at increased risk for subsequent vascular events despite effective use of statins to lower the low-density lipoprotein (LDL) cholesterol level. Niacin lowers the LDL cholesterol level and raises the high-density lipoprotein (HDL) cholesterol level, but its clinical efficacy and safety are uncertain. After a prerandomization run-in phase to standardize the background statin-based LDL cholesterol-lowering therapy and to establish participants' ability to take extended-release niacin without clinically significant adverse effects, we randomly assigned 25,673 adults with vascular disease to receive 2 g of extended-release niacin and 40 mg of laropiprant or a matching placebo daily. The primary outcome was the first major vascular event (nonfatal myocardial infarction, death from coronary causes, stroke, or arterial revascularization). During a median follow-up period of 3.9 years, participants who were assigned to extended-release niacin-laropiprant had an LDL cholesterol level that was an average of 10 mg per deciliter (0.25 mmol per liter as measured in the central laboratory) lower and an HDL cholesterol level that was an average of 6 mg per deciliter (0.16 mmol per liter) higher than the levels in those assigned to placebo. Assignment to niacin-laropiprant, as compared with assignment to placebo, had no significant effect on the incidence of major vascular events (13.2% and 13.7% of participants with an event, respectively; rate ratio, 0.96; 95% confidence interval [CI], 0.90 to 1.03; P=0.29). Niacin-laropiprant was associated with an increased incidence of disturbances in diabetes control that were considered to be serious (absolute excess as compared with placebo, 3.7 percentage points; P<0.001) and with an increased incidence of diabetes diagnoses (absolute excess, 1.3 percentage points; P<0.001), as well as increases in serious adverse events associated with the gastrointestinal system (absolute excess, 1.0 percentage point; P<0.001), musculoskeletal system (absolute excess, 0.7 percentage points; P<0.001), skin (absolute excess, 0.3 percentage points; P=0.003), and unexpectedly, infection (absolute excess, 1.4 percentage points; P<0.001) and bleeding (absolute excess, 0.7 percentage points; P<0.001). Among participants with atherosclerotic vascular disease, the addition of extended-release niacin-laropiprant to statin-based LDL cholesterol-lowering therapy did not significantly reduce the risk of major vascular events but did increase the risk of serious adverse events. (Funded by Merck and others; HPS2-THRIVE ClinicalTrials.gov number, NCT00461630.).

  12. Developmental Changes in the Effect of Active Left and Right Head Rotation on Random Number Generation.

    PubMed

    Sosson, Charlotte; Georges, Carrie; Guillaume, Mathieu; Schuller, Anne-Marie; Schiltz, Christine

    2018-01-01

    Numbers are thought to be spatially organized along a left-to-right horizontal axis with small/large numbers on its left/right respectively. Behavioral evidence for this mental number line (MNL) comes from studies showing that the reallocation of spatial attention by active left/right head rotation facilitated the generation of small/large numbers respectively. While spatial biases in random number generation (RNG) during active movement are well established in adults, comparable evidence in children is lacking and it remains unclear whether and how children's access to the MNL is affected by active head rotation. To get a better understanding of the development of embodied number processing, we investigated the effect of active head rotation on the mean of generated numbers as well as the mean difference between each number and its immediately preceding response (the first order difference; FOD) not only in adults ( n = 24), but also in 7- to 11-year-old elementary school children ( n = 70). Since the sign and absolute value of FODs carry distinct information regarding spatial attention shifts along the MNL, namely their direction (left/right) and size (narrow/wide) respectively, we additionally assessed the influence of rotation on the total of negative and positive FODs regardless of their numerical values as well as on their absolute values. In line with previous studies, adults produced on average smaller numbers and generated smaller mean FODs during left than right rotation. More concretely, they produced more negative/positive FODs during left/right rotation respectively and the size of negative FODs was larger (in terms of absolute value) during left than right rotation. Importantly, as opposed to adults, no significant differences in RNG between left and right head rotations were observed in children. Potential explanations for such age-related changes in the effect of active head rotation on RNG are discussed. Altogether, the present study confirms that numerical processing is spatially grounded in adults and suggests that its embodied aspect undergoes significant developmental changes.

  13. Laboratory validation of an in-home method for assessing circadian phase using dim light melatonin onset (DLMO).

    PubMed

    Pullman, Rebecca E; Roepke, Stephanie E; Duffy, Jeanne F

    2012-06-01

    To determine whether an accurate circadian phase assessment could be obtained from saliva samples collected by patients in their home. Twenty-four individuals with a complaint of sleep initiation or sleep maintenance difficulty were studied for two evenings. Each participant received instructions for collecting eight hourly saliva samples in dim light at home. On the following evening they spent 9h in a laboratory room with controlled dim (<20 lux) light where hourly saliva samples were collected. Circadian phase of dim light melatonin onset (DLMO) was determined using both an absolute threshold (3 pg ml(-1)) and a relative threshold (two standard deviations above the mean of three baseline values). Neither threshold method worked well for one participant who was a "low-secretor". In four cases the participants' in-lab melatonin levels rose much earlier or were much higher than their at-home levels, and one participant appeared to take the at home samples out of order. Overall, the at-home and in-lab DLMO values were significantly correlated using both methods, and differed on average by 37 (± 19)min using the absolute threshold and by 54 (± 36)min using the relative threshold. The at-home assessment procedure was able to determine an accurate DLMO using an absolute threshold in 62.5% of the participants. Thus, an at-home procedure for assessing circadian phase could be practical for evaluating patients for circadian rhythm sleep disorders. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Do Local Social Hierarchies Matter for Mental Health? A Study of Neighborhood Social Status and Depressive Symptoms in Older Adults

    PubMed Central

    Cagney, Kathleen A.; Skarupski, Kimberly A.; Everson-Rose, Susan A.; Mendes de Leon, Carlos F.

    2016-01-01

    Abstract Objectives. Despite a well-established association between relative social position and health, stratification at smaller levels of social organization has received scant attention. Neighborhood is a localized context that has increasing relevance for adults as they age, thus one’s relative position within this type of mesolevel group may have an effect on mental health, independent of absolute level of social and economic resources. We examine the relationship between an older adult’s relative rank within their neighborhoods on two criteria and depressive symptoms. Method. Using data from the Chicago Health and Aging Project, neighborhood relative social position was ascertained for two social domains: income and social reputation (number of neighbors one knows well enough to visit). Using multilevel models, we estimated the effect of relative position within the neighborhood on depressive symptoms, net of absolute level for each domain and average neighborhood level. Results. Higher neighborhood relative rankings on both income and visiting neighbors were associated with fewer depressive symptoms. Although both were modest in effect, the gradient in depressive symptoms was three times steeper for the relative rank of visiting neighbors than for income. Men had steeper gradients than women in both domains, but no race differences were observed. Discussion. These findings suggest that an older adult’s relative position in a local social hierarchy is associated with his/her mental health, net of absolute position. PMID:26333821

  15. Acute physiological responses to different circuit training protocols.

    PubMed

    Monteiro, A G; Alveno, D A; Prado, M; Monteiro, G A; Ugrinowitsch, C; Aoki, M S; Piçarro, I C

    2008-12-01

    The purpose of present study was to compare the acute physiological responses to a circuit weight training with the responses to a combined circuit training (weight training and treadmill run). The sample consisted of 25 individuals at an average state of training, 10 men and 15 female, between 18 and 35 year old. There were selected 60 second sets of resistance exercises to the circuit weight training (CWT). Whereas in the combined circuit training (CCT), the subjects spent 30 seconds on the same resistance exercises and 30 seconds running on the treadmill. The rest intervals between the sets lasted 15 seconds. The analysis of variance (ANOVA) with 5% significance level was utilized to the statistical analysis of the results. Comparing circuit training protocols, it was noted that CCT elicits a higher relative and absolute VO2 and energy expenditure values than CWT for both genders (P<0.05). Regarding inter-gender comparison, males showed higher absolute and relative VO2 and absolute energy expenditure values for both CWT and CCT than females (P<0.05). Females showed a significant greater %VO2max value for both CWT and CCT. Due to the experimental conditions used to state both circuit training bouts (CWT and CCT), the VO2 rate found was higher than the values reported by previous studies which used heavier weight lift. CCT seems adequate to produce cardiovascular improvements and greater energy expenditure for both men and women, while CWT group classes are sufficient only for unfit women.

  16. SU-E-J-25: End-To-End (E2E) Testing On TomoHDA System Using a Real Pig Head for Intracranial Radiosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corradini, N; Leick, M; Bonetti, M

    Purpose: To determine the MVCT imaging uncertainty on the TomoHDA system for intracranial radiosurgery treatments. To determine the end-to-end (E2E) overall accuracy of the TomoHDA system for intracranial radiosurgery. Methods: A pig head was obtained from the butcher, cut coronally through the brain, and preserved in formaldehyde. The base of the head was fixed to a positioning plate allowing precise movement, i.e. translation and rotation, in all 6 axes. A repeatability test was performed on the pig head to determine uncertainty in the image bone registration algorithm. Furthermore, the test studied images with MVCT slice thicknesses of 1 and 3more » mm in unison with differing scan lengths. A sensitivity test was performed to determine the registration algorithm’s ability to find the absolute position of known translations/rotations of the pig head. The algorithm’s ability to determine absolute position was compared against that of manual operators, i.e. a radiation therapist and radiation oncologist. Finally, E2E tests for intracranial radiosurgery were performed by measuring the delivered dose distributions within the pig head using Gafchromic films. Results: The repeatability test uncertainty was lowest for the MVCTs of 1-mm slice thickness, which measured less than 0.10 mm and 0.12 deg for all axes. For the sensitivity tests, the bone registration algorithm performed better than human eyes and a maximum difference of 0.3 mm and 0.4 deg was observed for the axes. E2E test results in absolute position difference measured 0.03 ± 0.21 mm in x-axis and 0.28 ± 0.18 mm in y-axis. A maximum difference of 0.32 and 0.66 mm was observed in x and y, respectively. The average peak dose difference between measured and calculated dose was 2.7 cGy or 0.4%. Conclusion: Our tests using a pig head phantom estimate the TomoHDA system to have a submillimeter overall accuracy for intracranial radiosurgery.« less

  17. Absolute and Relative Socioeconomic Health Inequalities across Age Groups

    PubMed Central

    van Zon, Sander K. R.; Bültmann, Ute; Mendes de Leon, Carlos F.; Reijneveld, Sijmen A.

    2015-01-01

    Background The magnitude of socioeconomic health inequalities differs across age groups. It is less clear whether socioeconomic health inequalities differ across age groups by other factors that are known to affect the relation between socioeconomic position and health, like the indicator of socioeconomic position, the health outcome, gender, and as to whether socioeconomic health inequalities are measured in absolute or in relative terms. The aim is to investigate whether absolute and relative socioeconomic health inequalities differ across age groups by indicator of socioeconomic position, health outcome and gender. Methods The study sample was derived from the baseline measurement of the LifeLines Cohort Study and consisted of 95,432 participants. Socioeconomic position was measured as educational level and household income. Physical and mental health were measured with the RAND-36. Age concerned eleven 5-years age groups. Absolute inequalities were examined by comparing means. Relative inequalities were examined by comparing Gini-coefficients. Analyses were performed for both health outcomes by both educational level and household income. Analyses were performed for all age groups, and stratified by gender. Results Absolute and relative socioeconomic health inequalities differed across age groups by indicator of socioeconomic position, health outcome, and gender. Absolute inequalities were most pronounced for mental health by household income. They were larger in younger than older age groups. Relative inequalities were most pronounced for physical health by educational level. Gini-coefficients were largest in young age groups and smallest in older age groups. Conclusions Absolute and relative socioeconomic health inequalities differed cross-sectionally across age groups by indicator of socioeconomic position, health outcome and gender. Researchers should critically consider the implications of choosing a specific age group, in addition to the indicator of socioeconomic position and health outcome, as findings on socioeconomic health inequalities may differ between them. PMID:26717482

  18. A Special Application of Absolute Value Techniques in Authentic Problem Solving

    ERIC Educational Resources Information Center

    Stupel, Moshe

    2013-01-01

    There are at least five different equivalent definitions of the absolute value concept. In instances where the task is an equation or inequality with only one or two absolute value expressions, it is a worthy educational experience for learners to solve the task using each one of the definitions. On the other hand, if more than two absolute value…

  19. Radiance calibration of the High Altitude Observatory white-light coronagraph on Skylab

    NASA Technical Reports Server (NTRS)

    Poland, A. I.; Macqueen, R. M.; Munro, R. H.; Gosling, J. T.

    1977-01-01

    The processing of over 35,000 photographs of the solar corona obtained by the white-light coronograph on Skylab is described. Calibration of the vast amount of data was complicated by temporal effects of radiation fog and latent image loss. These effects were compensated by imaging a calibration step wedge on each data frame. Absolute calibration of the wedge was accomplished through comparison with a set of previously calibrated glass opal filters. Analysis employed average characteristic curves derived from measurements of step wedges from many frames within a given camera half-load. The net absolute accuracy of a given radiance measurement is estimated to be 20%.

  20. Large-Scale Simulation of Multi-Asset Ising Financial Markets

    NASA Astrophysics Data System (ADS)

    Takaishi, Tetsuya

    2017-03-01

    We perform a large-scale simulation of an Ising-based financial market model that includes 300 asset time series. The financial system simulated by the model shows a fat-tailed return distribution and volatility clustering and exhibits unstable periods indicated by the volatility index measured as the average of absolute-returns. Moreover, we determine that the cumulative risk fraction, which measures the system risk, changes at high volatility periods. We also calculate the inverse participation ratio (IPR) and its higher-power version, IPR6, from the absolute-return cross-correlation matrix. Finally, we show that the IPR and IPR6 also change at high volatility periods.

  1. Fiber-optic extrinsic Fabry-Perot vibration-isolated interferometer for use in absolute gravity meters.

    PubMed

    Canuteson, E L; Zumberge, M

    1996-07-01

    In an absolute gravity meter, a laser interferometer measures the position of a test mass that is falling ina vacuum. The calculated value of gravity is the average acceleration of the mass during a set ofdrops. Since systematic accelerations of the optical system will bias the measured value of gravity,various interferometer geometries have been implemented in the past to isolate the optical system fromground motion. We have developed and tested a low-finesse fiber-optic extrinsic Fabry-Perotinterferometer that is fixed to the mass of a critically damped seismometer in which the effects ofsystematic ground motion and acoustic vibrations are reduced.

  2. Tritium volume activity in the Baltic Sea in 1987-1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Styro, D.B.; Korotkov, V.P.

    Tritium volume activities measured in the Baltic Sea are summarized in this paper. Activity levels were determined by the liquid scintillation method with a LS-1000 counter. The field investigations showed that the tritium volume activity in the Baltic Sea can change substantially in absolute magnitude. Therefore, average volume activity is used as an indicator of natural content. Correlations between calculated (averaged) tritium activity levels and the Chernobyl accident are very briefly discussed. 7 refs., 2 figs., 1 tab.

  3. An Engaging Illustration of the Physical Differences among Menthol Stereoisomers

    ERIC Educational Resources Information Center

    Treadwell, Edward M.; Black, T. Howard

    2005-01-01

    An experiment illustrating stereochemical principles, like different physical properties in achiral environments, assignment of absolute stereochemistry, and the stereoisomeric relationships to differences in absolute stereochemistry is devised. A demonstration of how enantiomers have the same physical properties until placed in chiral…

  4. SU-F-E-09: Respiratory Signal Prediction Based On Multi-Layer Perceptron Neural Network Using Adjustable Training Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, W; Jiang, M; Yin, F

    Purpose: Dynamic tracking of moving organs, such as lung and liver tumors, under radiation therapy requires prediction of organ motions prior to delivery. The shift of moving organ may change a lot due to huge transform of respiration at different periods. This study aims to reduce the influence of that changes using adjustable training signals and multi-layer perceptron neural network (ASMLP). Methods: Respiratory signals obtained using a Real-time Position Management(RPM) device were used for this study. The ASMLP uses two multi-layer perceptron neural networks(MLPs) to infer respiration position alternately and the training sample will be updated with time. Firstly, amore » Savitzky-Golay finite impulse response smoothing filter was established to smooth the respiratory signal. Secondly, two same MLPs were developed to estimate respiratory position from its previous positions separately. Weights and thresholds were updated to minimize network errors according to Leverberg-Marquart optimization algorithm through backward propagation method. Finally, MLP 1 was used to predict 120∼150s respiration position using 0∼120s training signals. At the same time, MLP 2 was trained using 30∼150s training signals. Then MLP is used to predict 150∼180s training signals according to 30∼150s training signals. The respiration position is predicted as this way until it was finished. Results: In this experiment, the two methods were used to predict 2.5 minute respiratory signals. For predicting 1s ahead of response time, correlation coefficient was improved from 0.8250(MLP method) to 0.8856(ASMLP method). Besides, a 30% improvement of mean absolute error between MLP(0.1798 on average) and ASMLP(0.1267 on average) was achieved. For predicting 2s ahead of response time, correlation coefficient was improved from 0.61415 to 0.7098.Mean absolute error of MLP method(0.3111 on average) was reduced by 35% using ASMLP method(0.2020 on average). Conclusion: The preliminary results demonstrate that the ASMLP respiratory prediction method is more accurate than MLP method and can improve the respiration forecast accuracy.« less

  5. Accuracy of stated energy contents of restaurant foods.

    PubMed

    Urban, Lorien E; McCrory, Megan A; Dallal, Gerard E; Das, Sai Krupa; Saltzman, Edward; Weber, Judith L; Roberts, Susan B

    2011-07-20

    National recommendations for the prevention and treatment of obesity emphasize reducing energy intake. Foods purchased in restaurants provide approximately 35% of the daily energy intake in US individuals but the accuracy of the energy contents listed for these foods is unknown. To examine the accuracy of stated energy contents of foods purchased in restaurants. A validated bomb calorimetry technique was used to measure dietary energy in food from 42 restaurants, comprising 269 total food items and 242 unique foods. The restaurants and foods were randomly selected from quick-serve and sit-down restaurants in Massachusetts, Arkansas, and Indiana between January and June 2010. The difference between restaurant-stated and laboratory-measured energy contents, which were corrected for standard metabolizable energy conversion factors. The absolute stated energy contents were not significantly different from the absolute measured energy contents overall (difference of 10 kcal/portion; 95% confidence interval [CI], -15 to 34 kcal/portion; P = .52); however, the stated energy contents of individual foods were variable relative to the measured energy contents. Of the 269 food items, 50 (19%) contained measured energy contents of at least 100 kcal/portion more than the stated energy contents. Of the 10% of foods with the highest excess energy in the initial sampling, 13 of 17 were available for a second sampling. In the first analysis, these foods contained average measured energy contents of 289 kcal/portion (95% CI, 186 to 392 kcal/portion) more than the stated energy contents; in the second analysis, these foods contained average measured energy contents of 258 kcal/portion (95% CI, 154 to 361 kcal/portion) more than the stated energy contents (P <.001 for each vs 0 kcal/portion difference). In addition, foods with lower stated energy contents contained higher measured energy contents than stated, while foods with higher stated energy contents contained lower measured energy contents (P <.001). Stated energy contents of restaurant foods were accurate overall. However, there was substantial inaccuracy for some individual foods, with understated energy contents for those with lower energy contents.

  6. Accuracy of Stated Energy Contents of Restaurant Foods

    PubMed Central

    Urban, Lorien E.; McCrory, Megan A.; Dallal, Gerard E.; Das, Sai Krupa; Saltzman, Edward; Weber, Judith L.; Roberts, Susan B.

    2015-01-01

    Context National recommendations for the prevention and treatment of obesity emphasize reducing energy intake. Foods purchased in restaurants provide approximately 35% of the daily energy intake in US individuals but the accuracy of the energy contents listed for these foods is unknown. Objective To examine the accuracy of stated energy contents of foods purchased in restaurants. Design and Setting A validated bomb calorimetry technique was used to measure dietary energy in food from 42 restaurants, comprising 269 total food items and 242 unique foods. The restaurants and foods were randomly selected from quick-serve and sit-down restaurants in Massachusetts, Arkansas, and Indiana between January and June 2010. Main Outcome Measure The difference between restaurant-stated and laboratory-measured energy contents, which were corrected for standard metabolizable energy conversion factors. Results The absolute stated energy contents were not significantly different from the absolute measured energy contents overall (difference of 10 kcal/portion; 95% confidence interval [CI], −15 to 34 kcal/portion; P=.52); however, the stated energy contents of individual foods were variable relative to the measured energy contents. Of the 269 food items, 50 (19%) contained measured energy contents of at least 100 kcal/portion more than the stated energy contents. Of the 10% of foods with the highest excess energy in the initial sampling, 13 of 17 were available for a second sampling. In the first analysis, these foods contained average measured energy contents of 289 kcal/portion (95% CI, 186 to 392 kcal/portion) more than the stated energy contents; in the second analysis, these foods contained average measured energy contents of 258 kcal/portion (95% CI, 154 to 361 kcal/portion) more than the stated energy contents (P<.001 for each vs 0 kcal/portion difference). In addition, foods with lower stated energy contents contained higher measured energy contents than stated, while foods with higher stated energy contents contained lower measured energy contents (P<.001). Conclusions Stated energy contents of restaurant foods were accurate overall. However, there was substantial inaccuracy for some individual foods, with understated energy contents for those with lower energy contents. PMID:21771989

  7. Extrapolation of radiation thermometry scales for determining the transition temperature of metal-carbon points. Experiments with the Co-C

    NASA Astrophysics Data System (ADS)

    Battuello, M.; Girard, F.; Florio, M.

    2009-02-01

    Four independent radiation temperature scales approximating the ITS-90 at 900 nm, 950 nm and 1.6 µm have been realized from the indium point (429.7485 K) to the copper point (1357.77 K) which were used to derive by extrapolation the transition temperature T90(Co-C) of the cobalt-carbon eutectic fixed point. An INRIM cell was investigated and an average value T90(Co-C) = 1597.20 K was found with the four values lying within 0.25 K. Alternatively, thermodynamic approximated scales were realized by assigning to the fixed points the best presently available thermodynamic values and deriving T(Co-C). An average value of 1597.27 K was found (four values lying within 0.25 K). The standard uncertainties associated with T90(Co-C) and T(Co-C) were 0.16 K and 0.17 K, respectively. INRIM determinations are compatible with recent thermodynamic determinations on three different cells (values lying between 1597.11 K and 1597.25 K) and with the result of a comparison on the same cell by an absolute radiation thermometer and an irradiance measurement with filter radiometers which give values of 1597.11 K and 1597.43 K, respectively (Anhalt et al 2006 Metrologia 43 S78-83). The INRIM approach allows the determination of both ITS-90 and thermodynamic temperature of a fixed point in a simple way and can provide valuable support to absolute radiometric methods in defining the transition temperature of new high-temperature fixed points.

  8. Dynamical features of hazardous near-Earth objects

    NASA Astrophysics Data System (ADS)

    Emel'yanenko, V. V.; Naroenkov, S. A.

    2015-07-01

    We discuss the dynamical features of near-Earth objects moving in dangerous proximity to Earth. We report the computation results for the motions of all observed near-Earth objects over a 600-year-long time period: 300 years in the past and 300 years in the future. We analyze the dynamical features of Earth-approaching objects. In particular, we established that the observed distribution of geocentric velocities of dangerous objects depends on their size. No bodies with geocentric velocities smaller that 5 kms-1 have been found among hazardous objects with absolute magnitudes H <18, whereas 9% of observed objects with H <27 pass near Earth moving at such velocities. On the other hand, we found a tendency for geocentric velocities to increase at H >29. We estimated the distribution of absolute magnitudes of hazardous objects based on our analysis of the data for the asteroids that have passed close to Earth. We inferred the Earth-impact frequencies for objects of different sizes. Impacts of objects with H <18 with Earth occur on average once every 0.53 Myr, and impacts of objects with H <27—once every 130-240 years. We show that currently about 0.1% of all near-Earth objects with diameters greater than 10 m have been discovered. We point out the discrepancies between the estimates of impact rates of Chelyabinsk-type objects, determined from fireball observations and from the data of telescopic asteroid tracking surveys. These estimates can be reconciled assuming that Chelyabinsk-sized asteroids have very low albedos (about 0.02 on average).

  9. Reliability and Validity of Ten Consumer Activity Trackers Depend on Walking Speed.

    PubMed

    Fokkema, Tryntsje; Kooiman, Thea J M; Krijnen, Wim P; VAN DER Schans, Cees P; DE Groot, Martijn

    2017-04-01

    To examine the test-retest reliability and validity of ten activity trackers for step counting at three different walking speeds. Thirty-one healthy participants walked twice on a treadmill for 30 min while wearing 10 activity trackers (Polar Loop, Garmin Vivosmart, Fitbit Charge HR, Apple Watch Sport, Pebble Smartwatch, Samsung Gear S, Misfit Flash, Jawbone Up Move, Flyfit, and Moves). Participants walked three walking speeds for 10 min each; slow (3.2 km·h), average (4.8 km·h), and vigorous (6.4 km·h). To measure test-retest reliability, intraclass correlations (ICC) were determined between the first and second treadmill test. Validity was determined by comparing the trackers with the gold standard (hand counting), using mean differences, mean absolute percentage errors, and ICC. Statistical differences were calculated by paired-sample t tests, Wilcoxon signed-rank tests, and by constructing Bland-Altman plots. Test-retest reliability varied with ICC ranging from -0.02 to 0.97. Validity varied between trackers and different walking speeds with mean differences between the gold standard and activity trackers ranging from 0.0 to 26.4%. Most trackers showed relatively low ICC and broad limits of agreement of the Bland-Altman plots at the different speeds. For the slow walking speed, the Garmin Vivosmart and Fitbit Charge HR showed the most accurate results. The Garmin Vivosmart and Apple Watch Sport demonstrated the best accuracy at an average walking speed. For vigorous walking, the Apple Watch Sport, Pebble Smartwatch, and Samsung Gear S exhibited the most accurate results. Test-retest reliability and validity of activity trackers depends on walking speed. In general, consumer activity trackers perform better at an average and vigorous walking speed than at a slower walking speed.

  10. Detection and Dynamic Analysis of Space Debris in the Geo Ring

    NASA Astrophysics Data System (ADS)

    Lacruz, E.; Abad, C.; Downes, J. J.; Casanova, D.; Tresaco, E.

    2018-01-01

    There are different populations of space debris (SD) in the geostationary (GEO) region. It is of great interest to know their dynamics, in order to contribute to aspects such as alerts against possible collisions, repositioning of GEO satellites or placing those satellites that come into service. In this contribution we present a study about the detection and dynamic analysis of SD located in the GEO ring. Using the telescopes of the Venezuelan Obseratory National (VON), a large amount of astrometric observations have been acquired. A preliminary dynamic analysis of them has been carried out, which evidences the average relative motion of these orbiters with a mean absolute error for coordinates of ≍ 0.09 pix.

  11. Conservatism implications of shock test tailoring for multiple design environments

    NASA Technical Reports Server (NTRS)

    Baca, Thomas J.; Bell, R. Glenn; Robbins, Susan A.

    1987-01-01

    A method for analyzing shock conservation in test specifications that have been tailored to qualify a structure for multiple design environments is discussed. Shock test conservation is qualified for shock response spectra, shock intensity spectra and ranked peak acceleration data in terms of an Index of Conservation (IOC) and an Overtest Factor (OTF). The multi-environment conservation analysis addresses the issue of both absolute and average conservation. The method is demonstrated in a case where four laboratory tests have been specified to qualify a component which must survive seven different field environments. Final judgment of the tailored test specification is shown to require an understanding of the predominant failure modes of the test item.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cherpak, Amanda

    Purpose: The Octavius 1000{sup SRS} detector was commissioned in December 2014 and is used routinely for verification of all SRS and SBRT plans. Results of verifications were analyzed to assess trends and limitations of the device and planning methods. Methods: Plans were delivered using a True Beam STx and results were evaluated using gamma analysis (95%, 3%/3mm) and absolute dose difference (5%). Verification results were analyzed based on several plan parameters including tumour volume, degree of modulation and prescribed dose. Results: During a 12 month period, a total of 124 patient plans were verified using the Octavius detector. Thirteen plansmore » failed the gamma criteria, while 7 plans failed based on the absolute dose difference. When binned according to degree of modulation, a significant correlation was found between MU/cGy and both mean dose difference (r=0.78, p<0.05) and gamma (r=−0.60, p<0.05). When data was binned according to tumour volume, the standard deviation of average gamma dropped from 2.2% – 3.7% for the volumes less than 30 cm{sup 3} to below 1% for volumes greater than 30 cm{sup 3}. Conclusions: The majority of plans and verification failures involved tumour volumes smaller than 30 cm{sup 3}. This was expected due to the nature of disease treated with SBRT and SRS techniques and did not increase rate of failure. Correlations found with MU/cGy indicate that as modulation increased, results deteriorated but not beyond the previously set thresholds.« less

  13. Estimating a just-noticeable difference for ocular comfort in contact lens wearers.

    PubMed

    Papas, Eric B; Keay, Lisa; Golebiowski, Blanka

    2011-06-21

    To estimate the just-noticeable difference (JND) in ocular comfort rating by human, contact lens-wearing subjects using 1 to 100 numerical scales. Ostensibly identical, new contact lenses were worn simultaneously in both eyes by 40 subjects who made individual comfort ratings for each eye using a 100-point numerical ratings scale (NRS). Concurrently, interocular preference was indicated on a five-point Likert scale (1 to 5: strongly prefer right, slightly prefer right, no preference, slightly prefer left, strongly prefer left, respectively). Differences in NRS comfort score (ΔC) between the right and left eyes were determined for each Likert scale preference criteria. The distribution of group ΔC scores was examined relative to alternative definitions of JND as a means of estimating its value. For Likert scores indicating the presence of a slight interocular preference, absolute ΔC ranged from 1 to 30 units with a mean of 7.4 ± 1.3 (95% confidence interval) across all lenses and trials. When there was no Likert scale preference expressed between the eyes, absolute ΔC did not exceed 5 units. For ratings of comfort using a 100-point numerical rating scale, the inter-ocular JND is unlikely to be less than 5 units. The estimate for the average value in the population was approximately 7 to 8 units. These numbers indicate the lowest level at which changes in comfort measured with such scales are likely to be clinically significant.

  14. A new metric for assessing IMRT modulation complexity and plan deliverability.

    PubMed

    McNiven, Andrea L; Sharpe, Michael B; Purdie, Thomas G

    2010-02-01

    To evaluate the utility of a new complexity metric, the modulation complexity score (MCS), in the treatment planning and quality assurance processes and to evaluate the relationship of the metric with deliverability. A multisite (breast, rectum, prostate, prostate bed, lung, and head and neck) and site-specific (lung) dosimetric evaluation has been completed. The MCS was calculated for each beam and the overall treatment plan. A 2D diode array (MapCHECK, Sun Nuclear, Melbourne, FL) was used to acquire measurements for each beam. The measured and planned dose (PINNACLE3, Phillips, Madison, WI) was evaluated using different percent differences and distance to agreement (DTA) criteria (3%/ 3 mm and 2%/ 1 mm) and the relationship between the dosimetric results and complexity (as measured by the MCS or simple beam parameters) assessed. For the multisite analysis (243 plans total), the mean MCS scores for each treatment site were breast (0.92), rectum (0.858), prostate (0.837), prostate bed (0.652), lung (0.631), and head and neck (0.356). The MCS allowed for compilation of treatment site-specific statistics, which is useful for comparing different techniques, as well as for comparison of individual treatment plans with the typical complexity levels. For the six plans selected for dosimetry, the average diode percent pass rate was 98.7% (minimum of 96%) for 3%/3 mm evaluation criteria. The average difference in absolute dose measurement between the planned and measured dose was 1.7 cGy. The detailed lung analysis also showed excellent agreement between the measured and planned dose, as all beams had a diode percentage pass rate for 3%/3 mm criteria of greater than 95.9%, with an average pass rate of 99.0%. The average absolute maximum dose difference for the lung plans was 0.7 cGy. There was no direct correlation between the MCS and simple beam parameters which could be used as a surrogate for complexity level (i.e., number of segments or MU). An evaluation criterion of 2%/ 1 mm reliably allowed for the identification of beams that are dosimetrically robust. In this study we defined a robust beam or plan as one that maintained a diode percentage pass rate greater than 90% at 2%/ 1 mm, indicating delivery that was deemed accurate when compared to the planned dose, even under stricter evaluation criterion. MCS and MU threshold criteria were determined by defining a required specificity of 1.0. A MCS threshold of 0.8 allowed for identification of robust deliverability with a sensitivity of 0.36. In contrast, MU had a lower sensitivity of 0.23 for a threshold of 50 MU. The MCS allows for a quantitative assessment of plan complexity, on a fixed scale, that can be applied to all treatment sites and can provide more information related to dose delivery than simple beam parameters. This could prove useful throughout the entire treatment planning and QA process.

  15. Global plate motion frames: Toward a unified model

    NASA Astrophysics Data System (ADS)

    Torsvik, Trond H.; Müller, R. Dietmar; van der Voo, Rob; Steinberger, Bernhard; Gaina, Carmen

    2008-09-01

    Plate tectonics constitutes our primary framework for understanding how the Earth works over geological timescales. High-resolution mapping of relative plate motions based on marine geophysical data has followed the discovery of geomagnetic reversals, mid-ocean ridges, transform faults, and seafloor spreading, cementing the plate tectonic paradigm. However, so-called "absolute plate motions," describing how the fragments of the outer shell of the Earth have moved relative to a reference system such as the Earth's mantle, are still poorly understood. Accurate absolute plate motion models are essential surface boundary conditions for mantle convection models as well as for understanding past ocean circulation and climate as continent-ocean distributions change with time. A fundamental problem with deciphering absolute plate motions is that the Earth's rotation axis and the averaged magnetic dipole axis are not necessarily fixed to the mantle reference system. Absolute plate motion models based on volcanic hot spot tracks are largely confined to the last 130 Ma and ideally would require knowledge about the motions within the convecting mantle. In contrast, models based on paleomagnetic data reflect plate motion relative to the magnetic dipole axis for most of Earth's history but cannot provide paleolongitudes because of the axial symmetry of the Earth's magnetic dipole field. We analyze four different reference frames (paleomagnetic, African fixed hot spot, African moving hot spot, and global moving hot spot), discuss their uncertainties, and develop a unifying approach for connecting a hot spot track system and a paleomagnetic absolute plate reference system into a "hybrid" model for the time period from the assembly of Pangea (˜320 Ma) to the present. For the last 100 Ma we use a moving hot spot reference frame that takes mantle convection into account, and we connect this to a pre-100 Ma global paleomagnetic frame adjusted 5° in longitude to smooth the reference frame transition. Using plate driving force arguments and the mapping of reconstructed large igneous provinces to core-mantle boundary topography, we argue that continental paleolongitudes can be constrained with reasonable confidence.

  16. Genetic potential of black bean genotypes with predictable behaviors in multienvironment trials.

    PubMed

    Torga, P P; Melo, P G S; Pereira, H S; Faria, L C; Melo, L C

    2016-10-24

    The aim of this study was to evaluate the phenotypic stability and specific and broad adaptability of common black bean genotypes for the Central and Center-South regions of Brazil by using the Annicchiarico and AMMI (weighted average of absolute scores: WAAS, and weighted average of absolute scores and productivity: WAASP) methodologies. We carried out 69 trials, with 43 and 26 trials in the Central and Center-South regions, respectively. Thirteen genotypes were evaluated in a randomized block design with three replications, during the rainy, dry, and winter seasons in 2 years. To obtain estimates of specific adaptation, we analyzed the parameters for each method obtained in the two geographic regions separately. To estimate broad adaptation, we used the average of the parameters obtained from each region. The lines identified with high specific adaptation in each region were not the same based on the Annicchiarico and AMMI (WAAS) methodologies. It was not possible to identify the same genotypes with specific or broad stability by using these methods. By contrast, the Annicchiarico and AMMI (WAASP) methods presented very similar estimates of broad and specific adaptation. Based on these methods, the lines with more specific adaptation were CNFP 8000 and CNFP 7994, in the Central and Center-South regions, respectively, of which the CNFP 8000 line was more widely adapted.

  17. First Absolutely Calibrated Localized Measurements of Ion Velocity in the MST in Locked and Rotating Plasmas

    NASA Astrophysics Data System (ADS)

    Baltzer, M.; Craig, D.; den Hartog, D. J.; Nornberg, M. D.; Munaretto, S.

    2015-11-01

    An Ion Doppler Spectrometer (IDS) is used on MST for high time-resolution passive and active measurements of impurity ion emission. Absolutely calibrated measurements of flow are difficult because the spectrometer records data within 0.3 nm of the C+5 line of interest, and commercial calibration lamps do not produce lines in this narrow range . A novel optical system was designed to absolutely calibrate the IDS. The device uses an UV LED to produce a broad emission curve in the desired region. A Fabry-Perot etalon filters this light, cutting transmittance peaks into the pattern of the LED emission. An optical train of fused silica lenses focuses the light into the IDS with f/4. A holographic diffuser blurs the light cone to increase homogeneity. Using this light source, the absolute Doppler shift of ion emissions can be measured in MST plasmas. In combination with charge exchange recombination spectroscopy, localized ion velocities can now be measured. Previously, a time-averaged measurement along the chord bisecting the poloidal plane was used to calibrate the IDS; the quality of these central chord calibrations can be characterized with our absolute calibration. Calibration errors may also be quantified and minimized by optimizing the curve-fitting process. Preliminary measurements of toroidal velocity in locked and rotating plasmas will be shown. This work has been supported by the US DOE.

  18. Subjective wellbeing and income: Empirical patterns in the rural developing world.

    PubMed

    Reyes-García, Victoria; Babigumira, Ronnie; Pyhälä, Aili; Wunder, Sven; Zorondo-Rodríguez, Francisco; Angelsen, Arild

    2016-04-01

    A commonality in the economics of happiness literature is that absolute income matters more for the subjective wellbeing of people at low income levels. In this article, we use a large sample of people in rural areas of developing countries with relatively low income levels to test whether subjective wellbeing an increasing function of absolute income in our sample, and to analyze the existence of adaptation and social comparison effects on subjective wellbeing. Our sample includes 6973 rural households in 23 countries throughout Asia, Africa, and Latin America. The average total income per adult equivalent in our sample was US$1555, whereas levels of subjective wellbeing resembled levels found in previous research using cross-country data. We find that, despite low levels of absolute income, levels of subjective wellbeing of our respondents resemble levels found in previous research using cross-country data. We also find remarkable similarities in many of the determinants of subjective wellbeing previously tested. Our data show that absolute income covariates with subjective wellbeing, but -as for richer samples- the magnitude of the association is lower once we control for adaptation and social comparison. Finally, our results suggest that social comparison has a stronger effect than adaptation in explaining the subjective wellbeing of our sample. Our findings highlight the importance of adaptation and social comparison even at low levels of absolute income.

  19. Subjective wellbeing and income: Empirical patterns in the rural developing world

    PubMed Central

    Reyes-García, Victoria; Babigumira, Ronnie; Pyhälä, Aili; Wunder, Sven; Zorondo-Rodríguez, Francisco; Angelsen, Arild

    2016-01-01

    A commonality in the economics of happiness literature is that absolute income matters more for the subjective wellbeing of people at low income levels. In this article, we use a large sample of people in rural areas of developing countries with relatively low income levels to test whether subjective wellbeing an increasing function of absolute income in our sample, and to analyze the existence of adaptation and social comparison effects on subjective wellbeing. Our sample includes 6973 rural households in 23 countries throughout Asia, Africa, and Latin America. The average total income per adult equivalent in our sample was US$1555, whereas levels of subjective wellbeing resembled levels found in previous research using cross-country data. We find that, despite low levels of absolute income, levels of subjective wellbeing of our respondents resemble levels found in previous research using cross-country data. We also find remarkable similarities in many of the determinants of subjective wellbeing previously tested. Our data show that absolute income covariates with subjective wellbeing, but -as for richer samples- the magnitude of the association is lower once we control for adaptation and social comparison. Finally, our results suggest that social comparison has a stronger effect than adaptation in explaining the subjective wellbeing of our sample. Our findings highlight the importance of adaptation and social comparison even at low levels of absolute income. PMID:27642259

  20. Parametric Study of Flow Control Over a Hump Model Using an Unsteady Reynolds- Averaged Navier-Stokes Code

    NASA Technical Reports Server (NTRS)

    Rumsey, Christopher L.; Greenblatt, David

    2007-01-01

    This is an expanded version of a limited-length paper that appeared at the 5th International Symposium on Turbulence and Shear Flow Phenomena by the same authors. A computational study was performed for steady and oscillatory flow control over a hump model with flow separation to assess how well the steady and unsteady Reynolds-averaged Navier-Stokes equations predict trends due to Reynolds number, control magnitude, and control frequency. As demonstrated in earlier studies, the hump model case is useful because it clearly demonstrates a failing in all known turbulence models: they under-predict the turbulent shear stress in the separated region and consequently reattachment occurs too far downstream. In spite of this known failing, three different turbulence models were employed to determine if trends can be captured even though absolute levels are not. Overall the three turbulence models showed very similar trends as experiment for steady suction, but only agreed qualitatively with some of the trends for oscillatory control.

  1. Interobserver Reliability of the Total Body Score System for Quantifying Human Decomposition.

    PubMed

    Dabbs, Gretchen R; Connor, Melissa; Bytheway, Joan A

    2016-03-01

    Several authors have tested the accuracy of the Total Body Score (TBS) method for quantifying decomposition, but none have examined the reliability of the method as a scoring system by testing interobserver error rates. Sixteen participants used the TBS system to score 59 observation packets including photographs and written descriptions of 13 human cadavers in different stages of decomposition (postmortem interval: 2-186 days). Data analysis used a two-way random model intraclass correlation in SPSS (v. 17.0). The TBS method showed "almost perfect" agreement between observers, with average absolute correlation coefficients of 0.990 and average consistency correlation coefficients of 0.991. While the TBS method may have sources of error, scoring reliability is not one of them. Individual component scores were examined, and the influences of education and experience levels were investigated. Overall, the trunk component scores were the least concordant. Suggestions are made to improve the reliability of the TBS method. © 2016 American Academy of Forensic Sciences.

  2. Pixel-by-pixel absolute phase retrieval using three phase-shifted fringe patterns without markers

    NASA Astrophysics Data System (ADS)

    Jiang, Chufan; Li, Beiwen; Zhang, Song

    2017-04-01

    This paper presents a method that can recover absolute phase pixel by pixel without embedding markers on three phase-shifted fringe patterns, acquiring additional images, or introducing additional hardware component(s). The proposed three-dimensional (3D) absolute shape measurement technique includes the following major steps: (1) segment the measured object into different regions using rough priori knowledge of surface geometry; (2) artificially create phase maps at different z planes using geometric constraints of structured light system; (3) unwrap the phase pixel by pixel for each region by properly referring to the artificially created phase map; and (4) merge unwrapped phases from all regions into a complete absolute phase map for 3D reconstruction. We demonstrate that conventional three-step phase-shifted fringe patterns can be used to create absolute phase map pixel by pixel even for large depth range objects. We have successfully implemented our proposed computational framework to achieve absolute 3D shape measurement at 40 Hz.

  3. Properties and evolution of NEO families created by tidal disruption at Earth

    NASA Astrophysics Data System (ADS)

    Schunová, Eva; Jedicke, Robert; Walsh, Kevin J.; Granvik, Mikael; Wainscoat, Richard J.; Haghighipour, Nader

    2014-08-01

    We have calculated the coherence and detectable lifetimes of synthetic near-Earth object (NEO) families created by catastrophic disruption of a progenitor as it suffers a very close Earth approach. The closest or slowest approaches yield the most violent ‘s-class’ disruption events where the largest remaining fragment after disruption and reaccumulation retains less than 50% of the parent’s mass. The resulting fragments have a ‘string of pearls’ configuration after their reaccummulation into gravitationally bound components (Richardson, D.C., Bottke, W.F., Love, S.G. [1998]. Icarus 134, 47-76). We found that the average absolute magnitude (H) difference between the parent body and the largest fragment is ΔH∼1.0. The average slope of the absolute magnitude (H) distribution, N(H)∝10, for the fragments in the s-class families is steeper than the slope of the NEO population (Mainzer, A., et al. [2011]. Astrophys. J. 743, 156) in the same size range. The es remain coherent as statistically significant clusters of orbits within the NEO population for an average of τbarc=(14.7±0.6)×103 yr after disruption. The detectable lifetimes of tidally disrupted families are extremely short compared to the multi-Myr and -Gyr lifetimes of main belt families due to the chaotic dynamical environment in NEO space-they are detectable with the techniques developed by Fu et al. and Schunová et al. (Fu, H., Jedicke, R., Durda, D.D., Fevig, R., Binzel, R.P. [2005]. Icarus 178(2), 434-449 and Schunová, E., Granvik, M., Jedicke, R., Gronchi, G., Wainscoat, R., Abe, S. [2012]. Icarus 220, 1050-1063) for an average duration (τbardet) ranging from about 2000 to about 12,000 years for progenitors in the absolute magnitude (Hp) range from 20 to 13 corresponding to diameters in the range from about 0.5 to 10 km respectively. The maximum absolute magnitude of a progenitor capable of producing an observable NEO family (i.e. detectable by our family finding technique) is Hp,max=20 (about 350 m diameter). The short detectability lifetime explains why zero NEO families have been discovered to-date. Nonetheless, every tidal disruption event of a progenitor with diameter greater than 0.5 km is capable of producing several million fragments in the 1-10 m diameter range that can contribute to temporary local density enhancements of small NEOs in Earth’s vicinity. We expect that there are about 1200 objects in the steady state NEO population in this size range due to tidal disruption assuming that one 1 km diameter NEO tidally disrupts at Earth every 2500 years. These objects may be suitable targets for asteroid retrieval missions due to their Earth-like orbits with corresponding low v∞ which permits low-cost missions. The fragments from the tidal disruptions evolve into orbits that bring them into collision with terrestrial planets or the Sun or they may be ejected from the Solar System on hyperbolic orbits due to deep planetary encounters. The end-state for the fragments from a tidal disruption at Earth have ∼5× the collision probability with Earth compared to the background NEO population.

  4. Implementation of street trees within the solar radiative exchange parameterization of TEB in SURFEX v8.0

    NASA Astrophysics Data System (ADS)

    Redon, Emilie C.; Lemonsu, Aude; Masson, Valéry; Morille, Benjamin; Musy, Marjorie

    2017-01-01

    The Town Energy Balance (TEB) model has been refined and improved in order to explicitly represent street trees and their impacts on radiative transfer: a new vegetated stratum on the vertical plane, which can shade the road, the walls, and the low vegetation has been added. This modification led to more complex radiative calculations, but has been done with a concern to preserve a certain level of simplicity and to limit the number of new input parameters for TEB to the cover fraction of trees, the mean height of trunks and trees, their specific leaf area index, and albedo. Indeed, the model is designed to be run over whole cities, for which it can simulate the local climatic variability related to urban landscape heterogeneity at the neighborhood scale. This means that computing times must be acceptable, and that input urban data must be available or easy to define. This simplified characterization of high vegetation necessarily induces some uncertainties in terms of the solar radiative exchanges, as quantified by comparison of TEB with a high-spatial-resolution solar enlightenment model (SOLENE). On the basis of an idealized geometry of an urban canyon with various vegetation layouts, TEB is evaluated regarding the total shortwave radiation flux absorbed by the elements that compose the canyon. TEB simulations in summer gathered best scores for all configurations and surfaces considered, which is precisely the most relevant season to assess the cooling effect of deciduous trees under temperate climate. Mean absolute differences and biases of 6.03 and +3.50 W m-2 for road, respectively, and of 3.38 and +2.80 W m-2 for walls have been recorded in vegetationless canyons. In view of the important incident radiation flux, exceeding 1000 W m-2 at solar noon, the mean absolute percentage differences of 3 % for both surfaces remain moderate. Concerning the vegetated canyons, we noted a high variability of statistical scores depending on the vegetation layout. The greater uncertainties are found for the solar radiation fluxes received and absorbed by the high vegetation. The mean absolute differences averaged over the vegetation configurations during summertime are 21.12 ± 13.39 W m-2 or 20.92 ± 10.87 % of mean absolute percentage differences for the total shortwave absorption, but these scores are associated with acceptable biases: -15.96 ± 15.93 W m-2.

  5. Absolute binding free energy calculations of CBClip host–guest systems in the SAMPL5 blind challenge

    PubMed Central

    Tofoleanu, Florentina; Pickard, Frank C.; König, Gerhard; Huang, Jing; Damjanović, Ana; Baek, Minkyung; Seok, Chaok; Brooks, Bernard R.

    2016-01-01

    Herein, we report the absolute binding free energy calculations of CBClip complexes in the SAMPL5 blind challenge. Initial conformations of CBClip complexes were obtained using docking and molecular dynamics simulations. Free energy calculations were performed using thermodynamic integration (TI) with soft-core potentials and Bennett’s acceptance ratio (BAR) method based on a serial insertion scheme. We compared the results obtained with TI simulations with soft-core potentials and Hamiltonian replica exchange simulations with the serial insertion method combined with the BAR method. The results show that the difference between the two methods can be mainly attributed to the van der Waals free energies, suggesting that either the simulations used for TI or the simulations used for BAR, or both are not fully converged and the two sets of simulations may have sampled difference phase space regions. The penalty scores of force field parameters of the 10 guest molecules provided by CHARMM Generalized Force Field can be an indicator of the accuracy of binding free energy calculations. Among our submissions, the combination of docking and TI performed best, which yielded the root mean square deviation of 2.94 kcal/mol and an average unsigned error of 3.41 kcal/mol for the ten guest molecules. These values were best overall among all participants. However, our submissions had little correlation with experiments. PMID:27677749

  6. Comparison of Dst Forecast Models for Intense Geomagnetic Storms

    NASA Technical Reports Server (NTRS)

    Ji, Eun-Young; Moon, Y.-J.; Gopalswamy, N.; Lee, D.-H.

    2012-01-01

    We have compared six disturbance storm time (Dst) forecast models using 63 intense geomagnetic storms (Dst <=100 nT) that occurred from 1998 to 2006. For comparison, we estimated linear correlation coefficients and RMS errors between the observed Dst data and the predicted Dst during the geomagnetic storm period as well as the difference of the value of minimum Dst (Delta Dst(sub min)) and the difference in the absolute value of Dst minimum time (Delta t(sub Dst)) between the observed and the predicted. As a result, we found that the model by Temerin and Li gives the best prediction for all parameters when all 63 events are considered. The model gives the average values: the linear correlation coefficient of 0.94, the RMS error of 14.8 nT, the Delta Dst(sub min) of 7.7 nT, and the absolute value of Delta t(sub Dst) of 1.5 hour. For further comparison, we classified the storm events into two groups according to the magnitude of Dst. We found that the model of Temerin and Lee is better than the other models for the events having 100 <= Dst < 200 nT, and three recent models (the model of Wang et al., the model of Temerin and Li, and the model of Boynton et al.) are better than the other three models for the events having Dst <= 200 nT.

  7. [Humidification assessment of four heat and moisture exchanger filters according to ISO 9360: 2000 standard].

    PubMed

    Lannoy, D; Décaudin, B; Resibois, J-P; Barrier, F; Wierre, L; Horrent, S; Batt, C; Moulront, S; Odou, P

    2008-02-01

    This work consisted of the assessment of humidification parameters and flow resistance for different heat and moisture exchanger filters (HMEF) used in intensive care unit. Four electrostatic HMEF were assessed: Hygrobac S (Tyco); Humidvent compact S (Teleflex); Hygrovent S/HME (Medisize-Dräger); Clear-Therm+HMEF (Intersurgical). Humidification parameters (loss of water weight, average absolute moisture [AAM], absolute variation of moisture) have been evaluated on a bench-test in conformity with the ISO 9360: 2000 standard, for 24h with the following ventilatory settings: tidal volume at 500 ml, respiratory rate at 15 c/min, and inspiration/expiration ratio at 1:1. The flow resistance of HMEFs assessed using the pressure drop method was measured before and after 24h of humidification for three increasing air flows of 30, 60, and 90 l/min. All the HMEFs allowed satisfactory level of humidification exceeding 30 mgH(2)O/l. The less powerful remained the Clear-Therm. Concerning HMEFs flow resistance, results showed a pressure drop slightly more important for the Hygrobac S filter as compared with other filters. This test showed differences between the HMEFs for both humidification and resistance parameters. When compared to the new version of the standards, HMEFs demonstrated their reliability. However, evolution of humidification and flow resistance characteristics over 24h showed a structural degradation of HMEFs, limiting their use over a longer period.

  8. A soft-computing methodology for noninvasive time-spatial temperature estimation.

    PubMed

    Teixeira, César A; Ruano, Maria Graça; Ruano, António E; Pereira, Wagner C A

    2008-02-01

    The safe and effective application of thermal therapies is restricted due to lack of reliable noninvasive temperature estimators. In this paper, the temporal echo-shifts of backscattered ultrasound signals, collected from a gel-based phantom, were tracked and assigned with the past temperature values as radial basis functions neural networks input information. The phantom was heated using a piston-like therapeutic ultrasound transducer. The neural models were assigned to estimate the temperature at different intensities and points arranged across the therapeutic transducer radial line (60 mm apart from the transducer face). Model inputs, as well as the number of neurons were selected using the multiobjective genetic algorithm (MOGA). The best attained models present, in average, a maximum absolute error less than 0.5 degrees C, which is pointed as the borderline between a reliable and an unreliable estimator in hyperthermia/diathermia. In order to test the spatial generalization capacity, the best models were tested using spatial points not yet assessed, and some of them presented a maximum absolute error inferior to 0.5 degrees C, being "elected" as the best models. It should be also stressed that these best models present implementational low-complexity, as desired for real-time applications.

  9. Dosimetric verification for primary focal hypermetabolism of nasopharyngeal carcinoma patients treated with dynamic intensity-modulated radiation therapy.

    PubMed

    Xin, Yong; Wang, Jia-Yang; Li, Liang; Tang, Tian-You; Liu, Gui-Hong; Wang, Jian-She; Xu, Yu-Mei; Chen, Yong; Zhang, Long-Zhen

    2012-01-01

    To make sure the feasibility with (18F)FDG PET/CT to guided dynamic intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma patients, by dosimetric verification before treatment. Chose 11 patients in III~IVA nasopharyngeal carcinoma treated with functional image-guided IMRT and absolute and relative dosimetric verification by Varian 23EX LA, ionization chamber, 2DICA of I'mRT Matrixx and IBA detachable phantom. Drawing outline and making treatment plan were by different imaging techniques (CT and (18F)FDG PET/CT). The dose distributions of the various regional were realized by SMART. The absolute mean errors of interest area were 2.39%±0.66 using 0.6 cc ice chamber. Results using DTA method, the average relative dose measurements within our protocol (3%, 3 mm) were 87.64% at 300 MU/min in all filed. Dosimetric verification before IMRT is obligatory and necessary. Ionization chamber and 2DICA of I'mRT Matrixx was the effective dosimetric verification tool for primary focal hyper metabolism in functional image-guided dynamic IMRT for nasopharyngeal carcinoma. Our preliminary evidence indicates that functional image-guided dynamic IMRT is feasible.

  10. Landsat-7 ETM+ on-orbit reflective-band radiometric stability and absolute calibration

    USGS Publications Warehouse

    Markham, B.L.; Thome, K.J.; Barsi, J.A.; Kaita, E.; Helder, Dennis L.; Barker, J. L.; Scaramuzza, Pat

    2004-01-01

    Launched in April 1999, the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) instrument is in its sixth year of operation. The ETM+ instrument has been the most stable of any of the Landsat instruments. To date, the best onboard calibration source for the reflective bands has been the Full Aperture Solar Calibrator, a solar-diffuser-based system, which has indicated changes of between 1% to 2% per year in the ETM+ gain for bands 1-4 and 8 and less than 0.5%/year for bands 5 and 7. However, most of this change is believed to be caused by changes in the solar diffuser panel, as opposed to a change in the instrument's gain. This belief is based partially on vicarious calibrations and observations of "invariant sites", hyperarid sites of the Sahara and Arabia. Weighted average slopes determined from these datasets suggest changes of 0.0% to 0.4% per year for bands 1-4 and 8 and 0.4% to 0.5% per year for bands 5 and 7. Absolute calibration of the reflective bands of the ETM+ is consistent with vicarious observations and other sensors generally at the 5% level, though there appear to be some systematic differences.

  11. Design principles and field performance of a solar spectral irradiance meter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tatsiankou, V.; Hinzer, K.; Haysom, J.

    2016-08-01

    A solar spectral irradiance meter (SSIM), designed for measuring the direct normal irradiance (DNI) in six wavelength bands, has been combined with models to determine key atmospheric transmittances and the resulting spectral irradiance distribution of DNI under all sky conditions. The design principles of the SSIM, implementation of a parameterized transmittance model, and field performance comparisons of modeled solar spectra with reference radiometer measurements are presented. Two SSIMs were tested and calibrated at the National Renewable Energy Laboratory (NREL) against four spectroradiometers and an absolute cavity radiometer. The SSIMs' DNI was on average within 1% of the DNI values reportedmore » by one of NREL's primary absolute cavity radiometers. An additional SSIM was installed at the SUNLAB Outdoor Test Facility in September 2014, with ongoing collection of environmental and spectral data. The SSIM's performance in Ottawa was compared against a commercial pyrheliometer and a spectroradiometer over an eight month study. The difference in integrated daily spectral irradiance between the SSIM and the ASD spectroradiometer was found to be less than 1%. The cumulative energy density collected by the SSIM over this duration agreed with that measured by an Eppley model NIP pyrheliometer to within 0.5%. No degradation was observed.« less

  12. A determination of the absolute radiant energy of a Robertson-Berger meter sunburn unit

    NASA Astrophysics Data System (ADS)

    DeLuisi, John J.; Harris, Joyce M.

    Data from a Robertson-Berger (RB) sunburn meter were compared with concurrent measurements obtained with an ultraviolet double monochromator (DM), and the absolute energy of one sunburn unit measured by the RB-meter was determined. It was found that at a solar zenith angle of 30° one sunburn unit (SU) is equivalent to 35 ± 4 mJ cm -2, and at a solar zenith angle of 69°, one SU is equivalent to 20 ± 2 mJ cm -2 (relative to a wavelength of 297 nm), where the rate of change is non-linear. The deviation is due to the different response functions of the RB-meter and the DM system used to simulate the response of human skin to the incident u.v. solar spectrum. The average growth rate of the deviation with increasing solar zenith angle was found to be 1.2% per degree between solar zenith angles 30 and 50° and 2.3% per degree between solar zenith angles 50 and 70°. The deviations of response with solar zenith angle were found to be consistent with reported RB-meter characteristics.

  13. Social inequality and ethnic differences in smoking in New Zealand.

    PubMed

    Barnett, Ross; Moon, Graham; Kearns, Robin

    2004-07-01

    This study tests a generalisation of the 'Wilkinson' thesis that the greater a nation's income inequality, the poorer the average national health status. We consider the effect of socio-economic inequality upon ethnic variations in smoking in New Zealand. Analysis of Maori and Pakeha (New Zealanders of European descent) smoking rates from the 1996 Census is conducted for 73 Territorial Local Authority areas in New Zealand, disaggregated by gender and rural-urban location. Partial correlation is used to control for absolute levels of deprivation and examine the independent effect of ethnic social inequality upon smoking rates. The level of social inequality between Maori and Pakeha has an independent effect on Maori smoking rates. Pakeha smoking rates by contrast are more sensitive to variations in absolute rather than relative deprivation. The effect of inequality is greatest for Maori women, especially among urban residents. By contrast, among Maori men the effects are greatest in rural areas. The results provide some qualified support for the Wilkinson thesis and suggest that policies which address fundamental issues of social inequality will play a small, but significant, role in helping to reduce high smoking rates amongst Maori. Copyright 2003 Elsevier Ltd.

  14. Dosimetric effects of seed anisotropy and interseed attenuation for {sup 103}Pd and {sup 125}I prostate implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chibani, Omar; Williamson, Jeffrey F.; Todor, Dorin

    2005-08-15

    A Monte Carlo study is carried out to quantify the effects of seed anisotropy and interseed attenuation for {sup 103}Pd and {sup 125}I prostate implants. Two idealized and two real prostate implants are considered. Full Monte Carlo simulation (FMCS) of implants (seeds are physically and simultaneously simulated) is compared with isotropic point-source dose-kernel superposition (PSKS) and line-source dose-kernel superposition (LSKS) methods. For clinical pre- and post-procedure implants, the dose to the different structures (prostate, rectum wall, and urethra) is calculated. The discretized volumes of these structures are reconstructed using transrectal ultrasound contours. Local dose differences (PSKS versus FMCS and LSKSmore » versus FMCS) are investigated. The dose contributions from primary versus scattered photons are calculated separately. For {sup 103}Pd, the average absolute total dose difference between FMCS and PSKS can be as high as 7.4% for the idealized model and 6.1% for the clinical preprocedure implant. Similarly, the total dose difference is lower for the case of {sup 125}I: 4.4% for the idealized model and 4.6% for a clinical post-procedure implant. Average absolute dose differences between LSKS and FMCS are less significant for both seed models: 3 to 3.6% for the idealized models and 2.9 to 3.2% for the clinical plans. Dose differences between PSKS and FMCS are due to the absence of both seed anisotropy and interseed attenuation modeling in the PSKS approach. LSKS accounts for seed anisotropy but not for the interseed effect, leading to systematically overestimated dose values in comparison with the more accurate FMCS method. For both idealized and clinical implants the dose from scattered photons represent less than 1/3 of the total dose. For all studied cases, LSKS prostate DVHs overestimate D{sub 90} by 2 to 5% because of the missing interseed attenuation effect. PSKS and LSKS predictions of V{sub 150} and V{sub 200} are overestimated by up to 9% in comparison with the FMCS results. Finally, effects of seed anisotropy and interseed attenuation must be viewed in the context of other significant sources of dose uncertainty, namely seed orientation, source misplacement, prostate morphological changes and tissue heterogeneity.« less

  15. Asymptotic Time Decay in Quantum Physics: a Selective Review and Some New Results

    NASA Astrophysics Data System (ADS)

    Marchetti, Domingos H. U.; Wreszinski, Walter F.

    2013-05-01

    Decay of various quantities (return or survival probability, correlation functions) in time are the basis of a multitude of important and interesting phenomena in quantum physics, ranging from spectral properties, resonances, return and approach to equilibrium, to dynamical stability properties and irreversibility and the "arrow of time" in [Asymptotic Time Decay in Quantum Physics (World Scientific, 2013)]. In this review, we study several types of decay — decay in the average, decay in the Lp-sense, and pointwise decay — of the Fourier-Stieltjes transform of a measure, usually identified with the spectral measure, which appear naturally in different mathematical and physical settings. In particular, decay in the Lp-sense is related both to pointwise decay and to decay in the average and, from a physical standpoint, relates to a rigorous form of the time-energy uncertainty relation. Both decay on the average and in the Lp-sense are related to spectral properties, in particular, absolute continuity of the spectral measure. The study of pointwise decay for singular continuous measures (Rajchman measures) provides a bridge between ergodic theory, number theory and analysis, including the method of stationary phase. The theory is illustrated by some new results in the theory of sparse models.

  16. The Research of Feature Extraction Method of Liver Pathological Image Based on Multispatial Mapping and Statistical Properties

    PubMed Central

    Liu, Huiling; Xia, Bingbing; Yi, Dehui

    2016-01-01

    We propose a new feature extraction method of liver pathological image based on multispatial mapping and statistical properties. For liver pathological images of Hematein Eosin staining, the image of R and B channels can reflect the sensitivity of liver pathological images better, while the entropy space and Local Binary Pattern (LBP) space can reflect the texture features of the image better. To obtain the more comprehensive information, we map liver pathological images to the entropy space, LBP space, R space, and B space. The traditional Higher Order Local Autocorrelation Coefficients (HLAC) cannot reflect the overall information of the image, so we propose an average correction HLAC feature. We calculate the statistical properties and the average gray value of pathological images and then update the current pixel value as the absolute value of the difference between the current pixel gray value and the average gray value, which can be more sensitive to the gray value changes of pathological images. Lastly the HLAC template is used to calculate the features of the updated image. The experiment results show that the improved features of the multispatial mapping have the better classification performance for the liver cancer. PMID:27022407

  17. Unsupervised parameter optimization for automated retention time alignment of severely shifted gas chromatographic data using the piecework alignment algorithm.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pierce, Karisa M.; Wright, Bob W.; Synovec, Robert E.

    2007-02-02

    First, simulated chromatographic separations with declining retention time precision were used to study the performance of the piecewise retention time alignment algorithm and to demonstrate an unsupervised parameter optimization method. The average correlation coefficient between the first chromatogram and every other chromatogram in the data set was used to optimize the alignment parameters. This correlation method does not require a training set, so it is unsupervised and automated. This frees the user from needing to provide class information and makes the alignment algorithm more generally applicable to classifying completely unknown data sets. For a data set of simulated chromatograms wheremore » the average chromatographic peak was shifted past two neighboring peaks between runs, the average correlation coefficient of the raw data was 0.46 ± 0.25. After automated, optimized piecewise alignment, the average correlation coefficient was 0.93 ± 0.02. Additionally, a relative shift metric and principal component analysis (PCA) were used to independently quantify and categorize the alignment performance, respectively. The relative shift metric was defined as four times the standard deviation of a given peak’s retention time in all of the chromatograms, divided by the peak-width-at-base. The raw simulated data sets that were studied contained peaks with average relative shifts ranging between 0.3 and 3.0. Second, a “real” data set of gasoline separations was gathered using three different GC methods to induce severe retention time shifting. In these gasoline separations, retention time precision improved ~8 fold following alignment. Finally, piecewise alignment and the unsupervised correlation optimization method were applied to severely shifted GC separations of reformate distillation fractions. The effect of piecewise alignment on peak heights and peak areas is also reported. Piecewise alignment either did not change the peak height, or caused it to slightly decrease. The average relative difference in peak height after piecewise alignment was –0.20%. Piecewise alignment caused the peak areas to either stay the same, slightly increase, or slightly decrease. The average absolute relative difference in area after piecewise alignment was 0.15%.« less

  18. Trends of relative and absolute socioeconomic equity in access to coronary revascularisations in 1995-2010 in Finland: a register study.

    PubMed

    Lumme, Sonja; Manderbacka, Kristiina; Keskimäki, Ilmo

    2017-02-20

    Resources for coronary revascularisations have increased substantially since the early 1990s in Finland. At the same time, ischaemic heart disease (IHD) mortality has decreased markedly. This study aims to examine how these changes have influenced trends in absolute and relative differences between socioeconomic groups in revascularisations and age group differences in them using IHD mortality as a proxy for need. Hospital Discharge Register data on revascularisations among Finns aged 45-84 in 1995-2010 were individually linked to population registers to obtain socio-demographic data. We measured absolute and relative income group differences in revascularisation and IHD mortality with slope index of inequality (SII) and concentration index (C), and relative equity taking need for care into account with horizontal inequity index (HII). The supply of procedures doubled during the years. Socioeconomic distribution of revascularisations was in absolute and relative terms equal in 1995 (Men: SII = -12, C = -0.00; Women, SII = -30, C = -0.03), but differences favouring low-income groups emerged by 2010 (M: SII = -340, C = -0.08; W: SII = -195, C = -0.14). IHD mortality decreased markedly, but absolute and relative differences favouring the better-off existed throughout study years. Absolute differences decreased somewhat (M: SII = -760 in 1995, SII = -681 in 2010; W: SII = -318 in 1995, SII = -211 in 2010), but relative differences increased significantly (M: C = -0.14 in 1995, C = -0.26 in 2010; W: C = -0.15 in 1995, C = -0.25 in 2010). HII was greater than zero in each year indicating inequity favouring the better-off. HII increased from 0.15 to 0.18 among men and from 0.10 to 0.12 among women. We found significant and increasing age group differences in HII. Despite large increase in supply of revascularisations and decrease in IHD mortality, there is still marked socioeconomic inequity in revascularisations in Finland. However, since changes in absolute distributions of both supply and need for coronary care have favoured low-income groups, absolute inequity can be claimed to have decreased although it cannot be quantified numerically.

  19. Validity of Automated Choroidal Segmentation in SS-OCT and SD-OCT.

    PubMed

    Zhang, Li; Buitendijk, Gabriëlle H S; Lee, Kyungmoo; Sonka, Milan; Springelkamp, Henriët; Hofman, Albert; Vingerling, Johannes R; Mullins, Robert F; Klaver, Caroline C W; Abràmoff, Michael D

    2015-05-01

    To evaluate the validity of a novel fully automated three-dimensional (3D) method capable of segmenting the choroid from two different optical coherence tomography scanners: swept-source OCT (SS-OCT) and spectral-domain OCT (SD-OCT). One hundred eight subjects were imaged using SS-OCT and SD-OCT. A 3D method was used to segment the choroid and quantify the choroidal thickness along each A-scan. The segmented choroidal posterior boundary was evaluated by comparing to manual segmentation. Differences were assessed to test the agreement between segmentation results of the same subject. Choroidal thickness was defined as the Euclidian distance between Bruch's membrane and the choroidal posterior boundary, and reproducibility was analyzed using automatically and manually determined choroidal thicknesses. For SS-OCT, the average choroidal thickness of the entire 6- by 6-mm2 macular region was 219.5 μm (95% confidence interval [CI], 204.9-234.2 μm), and for SD-OCT it was 209.5 μm (95% CI, 197.9-221.0 μm). The agreement between automated and manual segmentations was high: Average relative difference was less than 5 μm, and average absolute difference was less than 15 μm. Reproducibility of choroidal thickness between repeated SS-OCT scans was high (coefficient of variation [CV] of 3.3%, intraclass correlation coefficient [ICC] of 0.98), and differences between SS-OCT and SD-OCT results were small (CV of 11.0%, ICC of 0.73). We have developed a fully automated 3D method for segmenting the choroid and quantifying choroidal thickness along each A-scan. The method yielded high validity. Our method can be used reliably to study local choroidal changes and may improve the diagnosis and management of patients with ocular diseases in which the choroid is affected.

  20. Cannabis use in children with individualized risk profiles: Predicting the effect of universal prevention intervention.

    PubMed

    Miovský, Michal; Vonkova, Hana; Čablová, Lenka; Gabrhelík, Roman

    2015-11-01

    To study the effect of a universal prevention intervention targeting cannabis use in individual children with different risk profiles. A school-based randomized controlled prevention trial was conducted over a period of 33 months (n=1874 sixth-graders, baseline mean age 11.82). We used a two-level random intercept logistic model for panel data to predict the probabilities of cannabis use for each child. Specifically, we used eight risk/protective factors to characterize each child and then predicted two probabilities of cannabis use for each child if the child had the intervention or not. Using the two probabilities, we calculated the absolute and relative effect of the intervention for each child. According to the two probabilities, we also divided the sample into a low-risk group (the quarter of the children with the lowest probabilities), a moderate-risk group, and a high-risk group (the quarter of the children with the highest probabilities) and showed the average effect of the intervention on these groups. The differences between the intervention group and the control group were statistically significant in each risk group. The average predicted probabilities of cannabis use for a child from the low-risk group were 4.3% if the child had the intervention and 6.53% if no intervention was provided. The corresponding probabilities for a child from the moderate-risk group were 10.91% and 15.34% and for a child from the high-risk group 25.51% and 32.61%. School grades, thoughts of hurting oneself, and breaking the rules were the three most important factors distinguishing high-risk and low-risk children. We predicted the effect of the intervention on individual children, characterized by their risk/protective factors. The predicted absolute effect and relative effect of any intervention for any selected risk/protective profile of a given child may be utilized in both prevention practice and research. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Validation of GPU based TomoTherapy dose calculation engine.

    PubMed

    Chen, Quan; Lu, Weiguo; Chen, Yu; Chen, Mingli; Henderson, Douglas; Sterpin, Edmond

    2012-04-01

    The graphic processing unit (GPU) based TomoTherapy convolution/superposition(C/S) dose engine (GPU dose engine) achieves a dramatic performance improvement over the traditional CPU-cluster based TomoTherapy dose engine (CPU dose engine). Besides the architecture difference between the GPU and CPU, there are several algorithm changes from the CPU dose engine to the GPU dose engine. These changes made the GPU dose slightly different from the CPU-cluster dose. In order for the commercial release of the GPU dose engine, its accuracy has to be validated. Thirty eight TomoTherapy phantom plans and 19 patient plans were calculated with both dose engines to evaluate the equivalency between the two dose engines. Gamma indices (Γ) were used for the equivalency evaluation. The GPU dose was further verified with the absolute point dose measurement with ion chamber and film measurements for phantom plans. Monte Carlo calculation was used as a reference for both dose engines in the accuracy evaluation in heterogeneous phantom and actual patients. The GPU dose engine showed excellent agreement with the current CPU dose engine. The majority of cases had over 99.99% of voxels with Γ(1%, 1 mm) < 1. The worst case observed in the phantom had 0.22% voxels violating the criterion. In patient cases, the worst percentage of voxels violating the criterion was 0.57%. For absolute point dose verification, all cases agreed with measurement to within ±3% with average error magnitude within 1%. All cases passed the acceptance criterion that more than 95% of the pixels have Γ(3%, 3 mm) < 1 in film measurement, and the average passing pixel percentage is 98.5%-99%. The GPU dose engine also showed similar degree of accuracy in heterogeneous media as the current TomoTherapy dose engine. It is verified and validated that the ultrafast TomoTherapy GPU dose engine can safely replace the existing TomoTherapy cluster based dose engine without degradation in dose accuracy.

  2. Characteristics of a multisensor system for non invasive glucose monitoring with external validation and prospective evaluation.

    PubMed

    Caduff, Andreas; Mueller, Martin; Megej, Alexander; Dewarrat, Francois; Suri, Roland E; Klisic, Jelena; Donath, Marc; Zakharov, Pavel; Schaub, Dominik; Stahel, Werner A; Talary, Mark S

    2011-05-15

    The Multisensor Glucose Monitoring System (MGMS) features non invasive sensors for dielectric characterisation of the skin and underlying tissue in a wide frequency range (1 kHz-100 MHz, 1 and 2 GHz) as well as optical characterisation. In this paper we describe the results of using an MGMS in a miniaturised housing with fully integrated sensors and battery. Six patients with Type I Diabetes Mellitus (age 44±16 y; BMI 24.1±1.3 kg/m(2), duration of diabetes 27±12 y; HbA1c 7.3±1.0%) wore a single Multisensor at the upper arm position and performed a total of 45 in-clinic study days with 7 study days per patient on average (min. 5 and max. 10). Glucose changes were induced either orally or by i.v. glucose administration and the blood glucose was measured routinely. Several prospective data evaluation routines were applied to evaluate the data. The results are shown using one of the restrictive data evaluation routines, where measurements from the first 22 study days were used to train a linear regression model. The global model was then prospectively applied to the data of the remaining 23 study days to allow for an external validation of glucose prediction. The model application yielded a Mean Absolute Relative Difference of 40.8%, a Mean Absolute Difference of 51.9 mg dL(-1), and a correlation of 0.84 on average per study day. The Clarke error grid analyses showed 89.0% in A+B, 4.5% in C, 4.6% in D and 1.9% in the E region. Prospective application of a global, purely statistical model, demonstrates that glucose variations can be tracked non invasively by the MGMS in most cases under these conditions. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Relative arrival-time upper-mantle tomography and the elusive background mean

    NASA Astrophysics Data System (ADS)

    Bastow, Ian D.

    2012-08-01

    The interpretation of seismic tomographic images of upper-mantle seismic wave speed structure is often a matter of considerable debate because the observations can usually be explained by a range of hypotheses, including variable temperature, composition, anisotropy, and the presence of partial melt. An additional problem, often overlooked in tomographic studies using relative as opposed to absolute arrival-times, is the issue of the resulting velocity model's zero mean. In shield areas, for example, relative arrival-time analysis strips off a background mean velocity structure that is markedly fast compared to the global average. Conversely, in active areas, the background mean is often markedly slow compared to the global average. Appreciation of this issue is vital when interpreting seismic tomographic images: 'high' and 'low' velocity anomalies should not necessarily be interpreted, respectively, as 'fast' and 'slow' compared to 'normal mantle'. This issue has been discussed in the seismological literature in detail over the years, yet subsequent tomography studies have still fallen into the trap of mis-interpreting their velocity models. I highlight here some recent examples of this and provide a simple strategy to address the problem using constraints from a recent global tomographic model, and insights from catalogues of absolute traveltime anomalies. Consultation of such absolute measures of seismic wave speed should be routine during regional tomographic studies, if only for the benefit of the broader Earth Science community, who readily follow the red = hot and slow, blue = cold and fast rule of thumb when interpreting the images for themselves.

  4. Forecasting of Water Consumptions Expenditure Using Holt-Winter’s and ARIMA

    NASA Astrophysics Data System (ADS)

    Razali, S. N. A. M.; Rusiman, M. S.; Zawawi, N. I.; Arbin, N.

    2018-04-01

    This study is carried out to forecast water consumption expenditure of Malaysian university specifically at University Tun Hussein Onn Malaysia (UTHM). The proposed Holt-Winter’s and Auto-Regressive Integrated Moving Average (ARIMA) models were applied to forecast the water consumption expenditure in Ringgit Malaysia from year 2006 until year 2014. The two models were compared and performance measurement of the Mean Absolute Percentage Error (MAPE) and Mean Absolute Deviation (MAD) were used. It is found that ARIMA model showed better results regarding the accuracy of forecast with lower values of MAPE and MAD. Analysis showed that ARIMA (2,1,4) model provided a reasonable forecasting tool for university campus water usage.

  5. Measurement effects of seasonal and monthly variability on pedometer-determined data.

    PubMed

    Kang, Minsoo; Bassett, David R; Barreira, Tiago V; Tudor-Locke, Catrine; Ainsworth, Barbara E

    2012-03-01

    The seasonal and monthly variability of pedometer-determined physical activity and its effects on accurate measurement have not been examined. The purpose of the study was to reduce measurement error in step-count data by controlling a) the length of the measurement period and b) the season or month of the year in which sampling was conducted. Twenty-three middle-aged adults were instructed to wear a Yamax SW-200 pedometer over 365 consecutive days. The step-count measurement periods of various lengths (eg, 2, 3, 4, 5, 6, 7 days, etc.) were randomly selected 10 times for each season and month. To determine accurate estimates of yearly step-count measurement, mean absolute percentage error (MAPE) and bias were calculated. The year-round average was considered as a criterion measure. A smaller MAPE and bias represent a better estimate. Differences in MAPE and bias among seasons were trivial; however, they varied among different months. The months in which seasonal changes occur presented the highest MAPE and bias. Targeting the data collection during certain months (eg, May) may reduce pedometer measurement error and provide more accurate estimates of year-round averages.

  6. [Effect of Radix euphorbiae pekinensis extract on bioavailability of paclitaxel after their oral co-administration].

    PubMed

    Li, Minghua; Peng, Li; Yang, Fuheng; Liu, Sijia; Wang, Shengqi

    2015-06-01

    To evaluate the effect of Radix euphorbiae pekinensis extract on the permeability and bioavailability of paclitaxel co-administered orally. Based on Ussing Chamber and in vivo experiment, the permeability and bioavailability of paclitaxel were evaluated after oral co-administration with radix euphorbiae pekinensis in rats. The contents of paclitaxel in the permeates and the blood samples were determined using HPLC and LC-MS/MS method, respectively. In Radix euphorbiae pekinensis co-administration group, the Papp of the mucosal-to-serosal (M-S) transport or serosal-to-mucosal transport (S-M) of paclitaxel in the jejunum or ileum segment differed significantly from those in verapamil co-administration group and blank control group (P<0.05), but the Papp of S-M transport in the colon showed no significant difference from that in the blank control group. In the blank group, the average absolute bioavailability (AB%) of orally administered paclitaxel was only 2.81%, compared to that of 7.63% in radix euphorbiae pekinensis group. The average AB% in verapamil group was about 1.5 times that of the blank group. Co-administration of Radix euphorbiae pekinensis extract can increase the bioavailability of orally administered paclitaxel.

  7. Easy Absolute Values? Absolutely

    ERIC Educational Resources Information Center

    Taylor, Sharon E.; Mittag, Kathleen Cage

    2015-01-01

    The authors teach a problem-solving course for preservice middle-grades education majors that includes concepts dealing with absolute-value computations, equations, and inequalities. Many of these students like mathematics and plan to teach it, so they are adept at symbolic manipulations. Getting them to think differently about a concept that they…

  8. Absolute flatness measurements of silicon mirrors by a three-intersection method by near-infrared interferometry

    PubMed Central

    2013-01-01

    Absolute flatness of three silicon plane mirrors have been measured by a three-intersection method based on the three-flat method using a near-infrared interferometer. The interferometer was constructed using a near-infrared laser diode with a 1,310-nm wavelength light where the silicon plane mirror is transparent. The height differences at the coordinate values between the absolute line profiles by the three-intersection method have been evaluated. The height differences of the three flats were 4.5 nm or less. The three-intersection method using the near-infrared interferometer was useful for measuring the absolute flatness of the silicon plane mirrors. PMID:23758916

  9. The influence of sex and obesity on gait biomechanics in people with severe knee osteoarthritis scheduled for arthroplasty.

    PubMed

    Paterson, K L; Sosdian, L; Hinman, R S; Wrigley, T V; Kasza, J; Dowsey, M; Choong, P; Bennell, K L

    2017-11-01

    Sex and body mass may influence knee biomechanics associated with poor total knee arthroplasty (TKA) outcomes for knee osteoarthritis (OA). This study aimed to determine if gait differed between men and women, and overweight and class I obese patients with severe knee OA awaiting TKA. 34 patients with severe knee OA (average age 70.0 (SD 7.2) years, body mass index 30.3 (4.1kg/m 2 )) were recruited from a TKA waiting list. Three-dimensional gait analysis was performed at self-selected walking speed. Comparisons were made between men and women, and overweight (body mass index (BMI) 25.0-29.9kg/m 2 ) and class I obese (BMI 30.0-34.9kg/m 2 ) participants. Biomechanical outcomes included absolute and body size-adjusted peak knee adduction moment (KAM), KAM impulse, peak knee flexion moment, as well as peak knee flexion and varus-valgus angles, peak varus-valgus thrust, and peak vertical ground reaction force (GRF). Men had a higher absolute peak KAM, KAM impulse and peak GRF compared to women, and this sex-difference in frontal plane moments remained after adjusting for body size. However, when additionally adjusting for static knee alignment, differences disappeared. Knee biomechanics were similar between obesity groups after adjusting for the greater body weight of those with class I obesity. Men had greater KAM and KAM impulse even after adjustment for body size; however adjustment for their more varus knees removed this difference. Obesity group did not influence knee joint kinematics or moments. This suggests sex- and obesity-differences in these variables may not be associated with TKA outcomes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Analysis of the most recent data of Cascais Tide Gauge

    NASA Astrophysics Data System (ADS)

    Antunes, Carlos; Taborda, Rui; Mendes, Virgílio B.

    2010-05-01

    In order to meet international standards and to integrate sea level changes and tsunami monitoring networks, Cascais tide gauge, one of the oldest in the world, has been upgraded in 2003 with new acoustic equipment with digital data acquisition, temperature and air-pressure sensors, and internet connection for real time data. The new tide gauge is located very close to the old analogical gauge, which is still working. Datum links between both gauges and the permanent GPS station of Cascais were made and height differences between gauges and the GPS station have been monitored to verify site stability and to estimate the absolute vertical velocity of the site, and therefore, the absolute sea level changes. Tide gauge data from 2000 to 2009 has been analyzed and relative and absolute sea level rise rates have been estimated. The estimation of sea level rise rate with the short baseline of 10 years is made with the daily mean sea level data corrected from the inverse barometric effect. The relative sea level trend is obtained from a 60-day moving average run over the corrected daily mean sea level. The estimated rate has shown greater stability in contrast to the analysis of daily mean sea level raw data, which shows greater variability and uncertainty. Our results show a sea level rise rate of 2.6 mm/year (± 0.3 mm/year), higher than previous rates (2.1 mm/year for 1990 decade and 1.6 mm/year from 1920 to 2000), which is compatible with a sea level rise acceleration scenario. From the analysis of Cascais GPS data, for the period 1990.0 to 2010.0 we obtain an uplift rate of 0.3 mm/year leading to an absolute sea level rise of 2.9 mm/year for Cascais, under the assumption, as predicted by the ICE-5G model, that Cascais has no vertical displacement caused by the post-glacial isostatic adjustment.

  11. Comparison of measured and modelled negative hydrogen ion densities at the ECR-discharge HOMER

    NASA Astrophysics Data System (ADS)

    Rauner, D.; Kurutz, U.; Fantz, U.

    2015-04-01

    As the negative hydrogen ion density nH- is a key parameter for the investigation of negative ion sources, its diagnostic quantification is essential in source development and operation as well as for fundamental research. By utilizing the photodetachment process of negative ions, generally two different diagnostic methods can be applied: via laser photodetachment, the density of negative ions is measured locally, but only relatively to the electron density. To obtain absolute densities, the electron density has to be measured additionally, which induces further uncertainties. Via cavity ring-down spectroscopy (CRDS), the absolute density of H- is measured directly, however LOS-averaged over the plasma length. At the ECR-discharge HOMER, where H- is produced in the plasma volume, laser photodetachment is applied as the standard method to measure nH-. The additional application of CRDS provides the possibility to directly obtain absolute values of nH-, thereby successfully bench-marking the laser photodetachment system as both diagnostics are in good agreement. In the investigated pressure range from 0.3 to 3 Pa, the measured negative hydrogen ion density shows a maximum at 1 to 1.5 Pa and an approximately linear response to increasing input microwave powers from 200 up to 500 W. Additionally, the volume production of negative ions is 0-dimensionally modelled by balancing H- production and destruction processes. The modelled densities are adapted to the absolute measurements of nH- via CRDS, allowing to identify collisions of H- with hydrogen atoms (associative and non-associative detachment) to be the dominant loss process of H- in the plasma volume at HOMER. Furthermore, the characteristic peak of nH- observed at 1 to 1.5 Pa is identified to be caused by a comparable behaviour of the electron density with varying pressure, as ne determines the volume production rate via dissociative electron attachment to vibrationally excited hydrogen molecules.

  12. Principal component analysis-based imaging angle determination for 3D motion monitoring using single-slice on-board imaging.

    PubMed

    Chen, Ting; Zhang, Miao; Jabbour, Salma; Wang, Hesheng; Barbee, David; Das, Indra J; Yue, Ning

    2018-04-10

    Through-plane motion introduces uncertainty in three-dimensional (3D) motion monitoring when using single-slice on-board imaging (OBI) modalities such as cine MRI. We propose a principal component analysis (PCA)-based framework to determine the optimal imaging plane to minimize the through-plane motion for single-slice imaging-based motion monitoring. Four-dimensional computed tomography (4DCT) images of eight thoracic cancer patients were retrospectively analyzed. The target volumes were manually delineated at different respiratory phases of 4DCT. We performed automated image registration to establish the 4D respiratory target motion trajectories for all patients. PCA was conducted using the motion information to define the three principal components of the respiratory motion trajectories. Two imaging planes were determined perpendicular to the second and third principal component, respectively, to avoid imaging with the primary principal component of the through-plane motion. Single-slice images were reconstructed from 4DCT in the PCA-derived orthogonal imaging planes and were compared against the traditional AP/Lateral image pairs on through-plane motion, residual error in motion monitoring, absolute motion amplitude error and the similarity between target segmentations at different phases. We evaluated the significance of the proposed motion monitoring improvement using paired t test analysis. The PCA-determined imaging planes had overall less through-plane motion compared against the AP/Lateral image pairs. For all patients, the average through-plane motion was 3.6 mm (range: 1.6-5.6 mm) for the AP view and 1.7 mm (range: 0.6-2.7 mm) for the Lateral view. With PCA optimization, the average through-plane motion was 2.5 mm (range: 1.3-3.9 mm) and 0.6 mm (range: 0.2-1.5 mm) for the two imaging planes, respectively. The absolute residual error of the reconstructed max-exhale-to-inhale motion averaged 0.7 mm (range: 0.4-1.3 mm, 95% CI: 0.4-1.1 mm) using optimized imaging planes, averaged 0.5 mm (range: 0.3-1.0 mm, 95% CI: 0.2-0.8 mm) using an imaging plane perpendicular to the minimal motion component only and averaged 1.3 mm (range: 0.4-2.8 mm, 95% CI: 0.4-2.3 mm) in AP/Lateral orthogonal image pairs. The root-mean-square error of reconstructed displacement was 0.8 mm for optimized imaging planes, 0.6 mm for imaging plane perpendicular to the minimal motion component only, and 1.6 mm for AP/Lateral orthogonal image pairs. When using the optimized imaging planes for motion monitoring, there was no significant absolute amplitude error of the reconstructed motion (P = 0.0988), while AP/Lateral images had significant error (P = 0.0097) with a paired t test. The average surface distance (ASD) between overlaid two-dimensional (2D) tumor segmentation at end-of-inhale and end-of-exhale for all eight patients was 0.6 ± 0.2 mm in optimized imaging planes and 1.4 ± 0.8 mm in AP/Lateral images. The Dice similarity coefficient (DSC) between overlaid 2D tumor segmentation at end-of-inhale and end-of-exhale for all eight patients was 0.96 ± 0.03 in optimized imaging planes and 0.89 ± 0.05 in AP/Lateral images. Both ASD (P = 0.034) and DSC (P = 0.022) were significantly improved in the optimized imaging planes. Motion monitoring using imaging planes determined by the proposed PCA-based framework had significantly improved performance. Single-slice image-based motion tracking can be used for clinical implementations such as MR image-guided radiation therapy (MR-IGRT). © 2018 American Association of Physicists in Medicine.

  13. Impact resistant electrolytes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veith, Gabriel M.; Armstrong, Beth L.; Tenhaeff, Wyatt E.

    A passively impact resistant composite electrolyte composition includes an electrolyte solvent, up to 2M of an electrolyte salt, and shear thickening ceramic particles having a polydispersity index of no greater than 0.1, an average particle size of in a range of 50 nm to 1 .mu.m, and an absolute zeta potential of greater than .+-.40 mV.

  14. Evaluation of a commercial air filter for removal of viruses from the air.

    PubMed

    Roelants, P; Boon, B; Lhoest, W

    1968-10-01

    The effectiveness of a commercial absolute air filter for removal of viruses from air was tested with an actinophage, under the usual conditions of a laminar airflow clean room. A new method of dry phage dispersion is described. The filter showed an average reduction of 99.996% of airborne actinophage.

  15. 40 CFR 63.11224 - What are my monitoring, installation, operation, and maintenance requirements?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... include a daily calibration drift assessment, a quarterly performance audit, and an annual zero alignment... performance audit, or an annual zero alignment audit. (7) You must calculate and record 6-minute averages from... absolute particulate matter loadings. (5) The bag leak detection system must be equipped with a device to...

  16. 40 CFR 63.1350 - Monitoring requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... zero and 1.5 times the average temperature established according to the requirements in § 63.1349(b)(3... absolute PM loadings. (v) The BLDS must be equipped with a device to continuously record the output signal... must have provisions to determine the daily zero and upscale calibration drift (CD) (see sections 3.1...

  17. 40 CFR 63.11224 - What are my monitoring, installation, operation, and maintenance requirements?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... include a daily calibration drift assessment, a quarterly performance audit, and an annual zero alignment... performance audit, or an annual zero alignment audit. (7) You must calculate and record 6-minute averages from... absolute particulate matter loadings. (5) The bag leak detection system must be equipped with a device to...

  18. 40 CFR 63.1350 - Monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... zero and 1.5 times the average temperature established according to the requirements in § 63.1349(b)(3... absolute PM loadings. (v) The BLDS must be equipped with a device to continuously record the output signal... must have provisions to determine the daily zero and upscale calibration drift (CD) (see sections 3.1...

  19. The development of a novel approach for assessment of the first flush in urban stormwater discharges.

    PubMed

    Bach, P M; McCarthy, D T; Deletic, A

    2010-01-01

    The management of stormwater pollution has placed particular emphasis on the first flush phenomenon. However, definition and current methods of analyses of the phenomena contain serious limitations, the most important being their inability to capture a possible impact of the event size (total event volume) on the first flush. This paper presents the development of a novel approach in defining and assessing the first flush that should overcome these problems. The phenomenon is present in a catchment if the decrease in pollution concentration with the absolute cumulative volume of runoff from the catchment is statistically significant. Using data from seven diverse catchments around Melbourne, Australia, changes in pollutant concentrations for Total Suspended Solids (TSS) and Total Nitrogen (TN) were calculated over the absolute cumulative runoff and aggregated from a collection of different storm events. Due to the discrete nature of the water quality data, each concentration was calculated as a flow-weighted average at 2 mm runoff volume increments. The aggregated concentrations recorded in each increment (termed as a 'slice' of runoff) were statistically compared to each other across the absolute cumulative runoff volume. A first flush is then defined as the volume at which concentrations reach the 'background concentration' (i.e. the statistically significant minimum). Initial results clearly highlight first flush and background concentrations in all but one catchment supporting the validity of this new approach. Future work will need to address factors, which will help assess the first flush's magnitude and volume. Sensitivity testing and correlation with catchment characteristics should also be undertaken.

  20. Do Local Social Hierarchies Matter for Mental Health? A Study of Neighborhood Social Status and Depressive Symptoms in Older Adults.

    PubMed

    Kelley-Moore, Jessica A; Cagney, Kathleen A; Skarupski, Kimberly A; Everson-Rose, Susan A; Mendes de Leon, Carlos F

    2016-03-01

    Despite a well-established association between relative social position and health, stratification at smaller levels of social organization has received scant attention. Neighborhood is a localized context that has increasing relevance for adults as they age, thus one's relative position within this type of mesolevel group may have an effect on mental health, independent of absolute level of social and economic resources. We examine the relationship between an older adult's relative rank within their neighborhoods on two criteria and depressive symptoms. Using data from the Chicago Health and Aging Project, neighborhood relative social position was ascertained for two social domains: income and social reputation (number of neighbors one knows well enough to visit). Using multilevel models, we estimated the effect of relative position within the neighborhood on depressive symptoms, net of absolute level for each domain and average neighborhood level. Higher neighborhood relative rankings on both income and visiting neighbors were associated with fewer depressive symptoms. Although both were modest in effect, the gradient in depressive symptoms was three times steeper for the relative rank of visiting neighbors than for income. Men had steeper gradients than women in both domains, but no race differences were observed. These findings suggest that an older adult's relative position in a local social hierarchy is associated with his/her mental health, net of absolute position. © The Author 2015. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Participant roles of bullying in adolescence: Status characteristics, social behavior, and assignment criteria.

    PubMed

    Pouwels, J Loes; Lansu, Tessa A M; Cillessen, Antonius H N

    2016-01-01

    This study had three goals. First, we examined the prevalence of the participant roles of bullying in middle adolescence and possible gender differences therein. Second, we examined the behavioral and status characteristics associated with the participant roles in middle adolescence. Third, we compared two sets of criteria for assigning students to the participant roles of bullying. Participants were 1,638 adolescents (50.9% boys, M(age)  = 16.38 years, SD =.80) who completed the shortened participant role questionnaire and peer nominations for peer status and behavioral characteristics. Adolescents were assigned to the participant roles according to the relative criteria of Salmivalli, Lagerspetz, Björkqvist, Österman, and Kaukiainen (1996). Next, the students in each role were divided in two subgroups based on an additional absolute criterion: the Relative Only Criterion subgroup (nominated by less than 10% of their classmates) and the Absolute & Relative Criterion subgroup (nominated by at least 10% of their classmates). Adolescents who bullied or reinforced or assisted bullies were highly popular and disliked and scored high on peer-valued characteristics. Adolescents who were victimized held the weakest social position in the peer group. Adolescents who defended victims were liked and prosocial, but average in popularity and peer-valued characteristics. Outsiders held a socially weak position in the peer group, but were less disliked, less aggressive, and more prosocial than victims. The behavior and status profiles of adolescents in the participant roles were more extreme for the Absolute & Relative Criterion subgroup than for the Relative Only Criterion subgroup. © 2015 Wiley Periodicals, Inc.

  2. Early Acheulean technology in the Rietputs Formation, South Africa, dated with cosmogenic nuclides.

    PubMed

    Gibbon, Ryan J; Granger, Darryl E; Kuman, Kathleen; Partridge, Timothy C

    2009-02-01

    An absolute dating technique based on the build-up and decay of (26)Al and (10)Be in the mineral quartz provides crucial evidence regarding early Acheulean hominid distribution in South Africa. Cosmogenic nuclide burial dating of an ancient alluvial deposit of the Vaal River (Rietputs Formation) in the western interior of South Africa shows that coarse gravel and sand aggradation there occurred ca 1.57+/-0.22Ma, with individual ages of samples ranging from 1.89+/-0.19 to 1.34+/-0.22Ma. This was followed by aggradation of laminated and cross-bedded fine alluvium at ca 1.26+/-0.10Ma. The Rietputs Formation provides an ideal situation for the use of the cosmogenic nuclide burial dating method, as samples could be obtained from deep mining pits at depths ranging from 7 to 16 meters. Individual dates provide only a minimum age for the stone tool technology preserved within the deposits. Each assemblage represents a time averaged collection. Bifacial tools distributed throughout the coarse gravel and sand unit can be assigned to an early phase of the Acheulean. This is the first absolute radiometric dated evidence for early Acheulean artefacts in South Africa that have been found outside of the early hominid sites of the Gauteng Province. These absolute dates also indicate that handaxe-using hominids inhabited southern Africa as early as their counterparts in East Africa. The simultaneous appearance of the Acheulean in different parts of the continent implies relatively rapid technology development and the widespread use of large cutting tools in the African continent by ca 1.6Ma.

  3. Assessment of the Absolute Excitatory Level of the Retina by Flicker ERG.

    PubMed

    Tanimoto, Naoyuki; Seeliger, Mathias W

    2018-01-01

    Electroretinography (ERG) is important for functional diagnostics of the retina. Types of information about retinal function obtainable by ERG differ depending on recording conditions, e.g., a combination of light stimulus and adaptation. In terms of stimulation, single-flash and flicker stimuli are frequently used because response properties have been well investigated, allowing an assessment of fundamental retinal functionality; for example, how photoreceptors and bipolar cells, including signal transmission between them, are affected under pathological conditions. Usually, ERGs are recorded with a nonzero lower cutoff frequency of amplifiers to avoid certain artifacts, and additionally, responses are averaged over time so that non-event-related signals are cancelled out. However, the improved signal quality is associated with a loss of information. Especially in steady-state flicker ERG, information about the absolute baseline of recordings is missing because the prestimulus baseline is not included on the recording trace as well as because a zero response is obtained in all cases in which the signal baseline stays constant for a sufficient amount of time. In other words, it is impossible to tell from the conventional flicker ERG whether a zero signal is obtained under conditions of maximal or no excitation of the visual system. In this chapter, we describe a direct current ERG protocol (featuring a lower cutoff frequency of zero) with repetitive single flashes mimicking conventional flicker that contains a defined onset. Using this recording protocol, it is possible to assess not only the absolute excitatory level of the retina but also the development of steady-state responses from the single flash response.

  4. The absolute magnitudes of RR Lyraes from HIPPARCOS parallaxes and proper motions

    NASA Astrophysics Data System (ADS)

    Fernley, J.; Barnes, T. G.; Skillen, I.; Hawley, S. L.; Hanley, C. J.; Evans, D. W.; Solano, E.; Garrido, R.

    1998-02-01

    We have used HIPPARCOS proper motions and the method of Statistical Parallax to estimate the absolute magnitude of RR Lyrae stars. In addition we used the HIPPARCOS parallax of RR Lyrae itself to determine it's absolute magnitude. These two results are in excellent agreement with each other and give a zero-point for the RR Lyrae M_v,[Fe/H] relation of 0.77+/-0.15 at [Fe/H]=-1.53. This zero-point is in good agreement with that obtained recently by several groups using Baade-Wesselink methods which, averaged over the results from the different groups, gives M_v = 0.73+/-0.14 at [Fe/H]=-1.53. Taking the HIPPARCOS based zero-point and a value of 0.18+/-0.03 for the slope of the M_v,[Fe/H] relation from the literature we find firstly, the distance modulus of the LMC is 18.26+/-0.15 and secondly, the mean age of the Globular Clusters is 17.4+/-3.0 GYrs. These values are compared with recent estimates based on other "standard candles" that have also been calibrated with HIPPARCOS data. It is clear that, in addition to astrophysical problems, there are also problems in the application of HIPPARCOS data that are not yet fully understood. Table 1, which contains the basic data for the RR Lyraes, is available only at CDS. It may be retrieved via anonymous FTP at cdsarc.u-strasbg.fr (130.79.128.5) or via the Web at http://cdsweb.u-strasbg.fr/Abstract.html

  5. Estimation of the lower flammability limit of organic compounds as a function of temperature.

    PubMed

    Rowley, J R; Rowley, R L; Wilding, W V

    2011-02-15

    A new method of estimating the lower flammability limit (LFL) of general organic compounds is presented. The LFL is predicted at 298 K for gases and the lower temperature limit for solids and liquids from structural contributions and the ideal gas heat of formation of the fuel. The average absolute deviation from more than 500 experimental data points is 10.7%. In a previous study, the widely used modified Burgess-Wheeler law was shown to underestimate the effect of temperature on the lower flammability limit when determined in a large-diameter vessel. An improved version of the modified Burgess-Wheeler law is presented that represents the temperature dependence of LFL data determined in large-diameter vessels more accurately. When the LFL is estimated at increased temperatures using a combination of this model and the proposed structural-contribution method, an average absolute deviation of 3.3% is returned when compared with 65 data points for 17 organic compounds determined in an ASHRAE-style apparatus. Copyright © 2010 Elsevier B.V. All rights reserved.

  6. In vivo evaluation of axial integrity of coronary stents using intravascular ultrasound: Insights on longitudinal stent deformation.

    PubMed

    Dvir, Danny; Kitabata, Hironori; Barbash, Israel M; Minha, Sa'ar; Badr, Salem; Loh, Joshua P; Chen, Fang; Torguson, Rebecca; Waksman, Ron

    2014-09-01

    To evaluate the axial integrity of different coronary stents using intravascular ultrasound (IVUS). Longitudinal stent deformation was recently reported. Consecutive patients who underwent IVUS analysis after drug-eluting stent (DES) implantation for de novo coronary lesions were evaluated. Stent length was compared with label length for calculation of absolute change and relative difference (absolute change divided by label length). A total of 233 DES utilizing five different platforms were included. The median absolute change in stent length was 0.90 mm (interquartile range [IQR] 0.48-1.39) and the relative difference was 5.24% (IQR 2.55-8.29). There was no significant difference among the groups in median absolute or relative change: Cypher 0.89 mm/3.89%, Taxus 0.88 mm/5.39%, Endeavor 1.16 mm/6.77%, Xience V 0.86 mm/5.80%, and PROMUS Element 0.79 mm/5.34% (P = 0.085, P = 0.072, respectively). Multivariate logistic regression revealed that the Cypher stent was independently correlated with a lower change in length, whereas stent label length and deployment pressure were correlated with higher absolute change. The axial integrity of DES platforms examined in vivo was high, with only mild changes in stent length after implantation. While there are differences between first- and second-generation DES, axial integrity among second-generation DES was similar. © 2013 Wiley Periodicals, Inc.

  7. The solar wind effect on cosmic rays and solar activity

    NASA Technical Reports Server (NTRS)

    Fujimoto, K.; Kojima, H.; Murakami, K.

    1985-01-01

    The relation of cosmic ray intensity to solar wind velocity is investigated, using neutron monitor data from Kiel and Deep River. The analysis shows that the regression coefficient of the average intensity for a time interval to the corresponding average velocity is negative and that the absolute effect increases monotonously with the interval of averaging, tau, that is, from -0.5% per 100km/s for tau = 1 day to -1.1% per 100km/s for tau = 27 days. For tau 27 days the coefficient becomes almost constant independently of the value of tau. The analysis also shows that this tau-dependence of the regression coefficiently is varying with the solar activity.

  8. Study of average valence and valence electron distribution of several oxides using X-ray photoelectron spectra

    NASA Astrophysics Data System (ADS)

    Ding, L. L.; Wu, L. Q.; Ge, X. S.; Du, Y. N.; Qian, J. J.; Tang, G. D.; Zhong, W.

    2018-06-01

    X-ray photoelectron spectra of the O 1s electrons of MnFe2O4, ZnFe2O4, ZnO, and CaO were used to estimate the average valence, ValO, of the oxygen anions in these samples. The absolute values of ValO for these samples were found to be distinctly lower than the traditional value of 2.0, suggesting that the total average valences of the cations are also lower than the conventionally accepted values owing to valence balance in the compounds. In addition, we analyzed the valence band spectra of the samples and investigated the distribution characteristics of the valence electrons.

  9. Sex-related differences in foot shape of adult Caucasians--a follow-up study focusing on long and short feet.

    PubMed

    Krauss, I; Langbein, C; Horstmann, T; Grau, S

    2011-03-01

    The study's purpose was to substantiate findings on sex-related differences in foot morphology focusing on fringe sizes. Altogether, 287 Caucasian adults with long or short feet were scanned. Data were analysed together with data from 847 subjects from a previous study with comparable inclusion criteria and anthropometric data by: (1)comparing absolute measures within 237-277 mm foot length (FL); (2) comparing averaged measures across sizes in % of foot length for 203-323 mm FL; (3) reclassifying the additional subjects into a previously defined foot type classification. Male feet were wider and higher for the same FL. Averaged across sizes, no relevant differences between sexes were found for widths and heights. Slender or flat-pointed foot types were more common in longer feet, shorter feet tended to be bigger. Definitions for 'long' and 'short' are sex-related with an offset of three shoe sizes (EU). Results of this follow-up study on long and short feet can substantiate previous findings mainly described for the most common sizes. STATEMENT OF RELEVANCE: Improper footwear can cause pain and injury and proper fit is a major criterion for shoe buyers. Knowledge about sex-related differences in foot shape is important for shoe design. This study supplements the field of knowledge for very small and large feet.

  10. An Integrated Model of Choices and Response Times in Absolute Identification

    ERIC Educational Resources Information Center

    Brown, Scott D.; Marley, A. A. J.; Donkin, Christopher; Heathcote, Andrew

    2008-01-01

    Recent theoretical developments in the field of absolute identification have stressed differences between relative and absolute processes, that is, whether stimulus magnitudes are judged relative to a shorter term context provided by recently presented stimuli or a longer term context provided by the entire set of stimuli. The authors developed a…

  11. Understanding gas-surface interactions from direct force measurements using a specialized torsion balance

    NASA Technical Reports Server (NTRS)

    Cook, S. R.; Hoffbauer, M. A.

    1996-01-01

    The first comprehensive measurements of the magnitude and direction of the forces exerted on surfaces by molecular beams are discussed and used to obtain information about the microscopic properties of the gas-surface interactions. This unique approach is not based on microscopic measurements of the scattered molecules. The reduced force coefficients are introduced as a new set of parameters that completely describe the macroscopic average momentum transfer to a surface by an incident molecular beam. By using a specialized torsion balance and molecular beams of N2, CO, CO2, and H2, the reduced force coefficients are determined from direct measurements of the force components exerted on surface of a solar panel array material, Kapton, SiO2-coated Kapton, and Z-93 as a function of the angle of incidence ranging from 0 degrees to 85 degrees. The absolute flux densities of the molecular beams were measured using a different torsion balance with a beam-stop that nullified the force of the scattered molecules. Standard time-of-flight techniques were used to determine the flux-weighted average velocities of the various molecular beams ranging from 1600 m/s to 4600 m/s. The reduced force coefficients can be used to directly obtain macroscopic average properties of the scattered molecules, such as the flux-weighted average velocity and translational energy, that can then be used to determine microscopic details concerning gas-surface interactions without the complications associated with averaging microscopic measurements.

  12. Robust sleep quality quantification method for a personal handheld device.

    PubMed

    Shin, Hangsik; Choi, Byunghun; Kim, Doyoon; Cho, Jaegeol

    2014-06-01

    The purpose of this study was to develop and validate a novel method for sleep quality quantification using personal handheld devices. The proposed method used 3- or 6-axes signals, including acceleration and angular velocity, obtained from built-in sensors in a smartphone and applied a real-time wavelet denoising technique to minimize the nonstationary noise. Sleep or wake status was decided on each axis, and the totals were finally summed to calculate sleep efficiency (SE), regarded as sleep quality in general. The sleep experiment was carried out for performance evaluation of the proposed method, and 14 subjects participated. An experimental protocol was designed for comparative analysis. The activity during sleep was recorded not only by the proposed method but also by well-known commercial applications simultaneously; moreover, activity was recorded on different mattresses and locations to verify the reliability in practical use. Every calculated SE was compared with the SE of a clinically certified medical device, the Philips (Amsterdam, The Netherlands) Actiwatch. In these experiments, the proposed method proved its reliability in quantifying sleep quality. Compared with the Actiwatch, accuracy and average bias error of SE calculated by the proposed method were 96.50% and -1.91%, respectively. The proposed method was vastly superior to other comparative applications with at least 11.41% in average accuracy and at least 6.10% in average bias; average accuracy and average absolute bias error of comparative applications were 76.33% and 17.52%, respectively.

  13. MO-F-CAMPUS-J-04: Tissue Segmentation-Based MR Electron Density Mapping Method for MR-Only Radiation Treatment Planning of Brain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, H; Lee, Y; Ruschin, M

    2015-06-15

    Purpose: Automatically derive electron density of tissues using MR images and generate a pseudo-CT for MR-only treatment planning of brain tumours. Methods: 20 stereotactic radiosurgery (SRS) patients’ T1-weighted MR images and CT images were retrospectively acquired. First, a semi-automated tissue segmentation algorithm was developed to differentiate tissues with similar MR intensities and large differences in electron densities. The method started with approximately 12 slices of manually contoured spatial regions containing sinuses and airways, then air, bone, brain, cerebrospinal fluid (CSF) and eyes were automatically segmented using edge detection and anatomical information including location, shape, tissue uniformity and relative intensity distribution.more » Next, soft tissues - muscle and fat were segmented based on their relative intensity histogram. Finally, intensities of voxels in each segmented tissue were mapped into their electron density range to generate pseudo-CT by linearly fitting their relative intensity histograms. Co-registered CT was used as a ground truth. The bone segmentations of pseudo-CT were compared with those of co-registered CT obtained by using a 300HU threshold. The average distances between voxels on external edges of the skull of pseudo-CT and CT in three axial, coronal and sagittal slices with the largest width of skull were calculated. The mean absolute electron density (in Hounsfield unit) difference of voxels in each segmented tissues was calculated. Results: The average of distances between voxels on external skull from pseudo-CT and CT were 0.6±1.1mm (mean±1SD). The mean absolute electron density differences for bone, brain, CSF, muscle and fat are 78±114 HU, and 21±8 HU, 14±29 HU, 57±37 HU, and 31±63 HU, respectively. Conclusion: The semi-automated MR electron density mapping technique was developed using T1-weighted MR images. The generated pseudo-CT is comparable to that of CT in terms of anatomical position of tissues and similarity of electron density assignment. This method can allow MR-only treatment planning.« less

  14. Estimation of dynamic time activity curves from dynamic cardiac SPECT imaging

    NASA Astrophysics Data System (ADS)

    Hossain, J.; Du, Y.; Links, J.; Rahmim, A.; Karakatsanis, N.; Akhbardeh, A.; Lyons, J.; Frey, E. C.

    2015-04-01

    Whole-heart coronary flow reserve (CFR) may be useful as an early predictor of cardiovascular disease or heart failure. Here we propose a simple method to extract the time-activity curve, an essential component needed for estimating the CFR, for a small number of compartments in the body, such as normal myocardium, blood pool, and ischemic myocardial regions, from SPECT data acquired with conventional cameras using slow rotation. We evaluated the method using a realistic simulation of 99mTc-teboroxime imaging. Uptake of 99mTc-teboroxime based on data from the literature were modeled. Data were simulated using the anatomically-realistic 3D NCAT phantom and an analytic projection code that realistically models attenuation, scatter, and the collimator-detector response. The proposed method was then applied to estimate time activity curves (TACs) for a set of 3D volumes of interest (VOIs) directly from the projections. We evaluated the accuracy and precision of estimated TACs and studied the effects of the presence of perfusion defects that were and were not modeled in the estimation procedure. The method produced good estimates of the myocardial and blood-pool TACS organ VOIs, with average weighted absolute biases of less than 5% for the myocardium and 10% for the blood pool when the true organ boundaries were known and the activity distributions in the organs were uniform. In the presence of unknown perfusion defects, the myocardial TAC was still estimated well (average weighted absolute bias <10%) when the total reduction in myocardial uptake (product of defect extent and severity) was ≤5%. This indicates that the method was robust to modest model mismatch such as the presence of moderate perfusion defects and uptake nonuniformities. With larger defects where the defect VOI was included in the estimation procedure, the estimated normal myocardial and defect TACs were accurate (average weighted absolute bias ≈5% for a defect with 25% extent and 100% severity).

  15. Spatial and temporal variability of the overall error of National Atmospheric Deposition Program measurements determined by the USGS collocated-sampler program, water years 1989-2001

    USGS Publications Warehouse

    Wetherbee, G.A.; Latysh, N.E.; Gordon, J.D.

    2005-01-01

    Data from the U.S. Geological Survey (USGS) collocated-sampler program for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN) are used to estimate the overall error of NADP/NTN measurements. Absolute errors are estimated by comparison of paired measurements from collocated instruments. Spatial and temporal differences in absolute error were identified and are consistent with longitudinal distributions of NADP/NTN measurements and spatial differences in precipitation characteristics. The magnitude of error for calcium, magnesium, ammonium, nitrate, and sulfate concentrations, specific conductance, and sample volume is of minor environmental significance to data users. Data collected after a 1994 sample-handling protocol change are prone to less absolute error than data collected prior to 1994. Absolute errors are smaller during non-winter months than during winter months for selected constituents at sites where frozen precipitation is common. Minimum resolvable differences are estimated for different regions of the USA to aid spatial and temporal watershed analyses.

  16. Concurrently examining unrealistic absolute and comparative optimism: Temporal shifts, individual-difference and event-specific correlates, and behavioural outcomes.

    PubMed

    Ruthig, Joelle C; Gamblin, Bradlee W; Jones, Kelly; Vanderzanden, Karen; Kehn, Andre

    2017-02-01

    Researchers have spent considerable effort examining unrealistic absolute optimism and unrealistic comparative optimism, yet there is a lack of research exploring them concurrently. This longitudinal study repeatedly assessed unrealistic absolute and comparative optimism within a performance context over several months to identify the degree to which they shift as a function of proximity to performance and performance feedback, their associations with global individual difference and event-specific factors, and their link to subsequent behavioural outcomes. Results showed similar shifts in unrealistic absolute and comparative optimism based on proximity to performance and performance feedback. Moreover, increases in both types of unrealistic optimism were associated with better subsequent performance beyond the effect of prior performance. However, several differences were found between the two forms of unrealistic optimism in their associations with global individual difference factors and event-specific factors, highlighting the distinctiveness of the two constructs. © 2016 The British Psychological Society.

  17. Tray estimates for low reflux

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barna, B.A.; Ginn, R.F.

    1985-05-01

    In computer programs which perform shortcut calculations for multicomponent distillation, the Gilliland correlation continues to be used even though errors of up to 60% (compared with rigorous plate-to-plate calculations) were shown by Erbar and Maddox. Average absolute differences were approximately 30% for Gilliland's correlation versus 4% for the Erbar-Maddox method. The reason the Gilliland correlation continues to be used appears to be due to the availability of an equation by Eduljee which facilitates the correlation's use in computer program. A new equation is presented in this paper that represents the Erbar-Maddox correlation of trays with reflux for multicomponent distillation. Atmore » low reflux ratios, results show more trays are needed than would be estimated by Gilliland's method.« less

  18. Design for the optical retardation in broadband zero-order half-wave plates.

    PubMed

    Liu, Jin; Cai, Yi; Chen, Hongyi; Zeng, Xuanke; Zou, Da; Xu, Shixiang

    2011-04-25

    This paper presents a novel design for broadband zero-order half-wave plates to eliminate the first-order or up to second-order wavelength-dependent birefringent phase retardation (BPR) with 2 or 3 different birefringent materials. The residual BPRs of the plates increase monotonously with the wavelength deviation from a selected wavelength, so the plates are applicable to the broadband light pulses which gather most of the light energy around their central wavelengths. The model chooses the materials by the birefringent dispersion coefficient and evaluates the performances of the plates by the weighted average of the absolute value of residual BPR in order to emphasize the contributions of the incident spectral components whose possess higher energies.

  19. Determination of enthalpies of formation of energetic molecules with composite quantum chemical methods

    DOE PAGES

    Manaa, M. Riad; Fried, Laurence E.; Kuo, I-Feng W.

    2016-02-01

    We report gas-phase enthalpies of formation for the set of energetic molecules NTO, DADE, LLM-105, TNT, RDX, TATB, HMX, and PETN using the G2, G3, G4, and ccCA-PS3 quantum composite methods. Calculations for HMX and PETN hitherto represent the largest molecules attempted with these methods. G3 and G4 calculations are typically close to one another, with a larger difference found between these methods and ccCA-PS3. Furthermore there is significant uncertainty in experimental values, the mean absolute deviation between the average experimental value and calculations are 12, 6, 7, and 3 kcal/mol for G2, G3, G4, and ccCA-PS3, respectively.

  20. Diagnostic pure-tone audiometry in schools: mobile testing without a sound-treated environment.

    PubMed

    Swanepoel, De Wet; Maclennan-Smith, Felicity; Hall, James W

    2013-01-01

    To validate diagnostic pure-tone audiometry in schools without a sound-treated environment using an audiometer that incorporates insert earphones covered by circumaural earcups and real-time environmental noise monitoring. A within-subject repeated measures design was employed to compare air (250 to 8000 Hz) and bone (250 to 4000 Hz) conduction pure-tone thresholds measured in natural school environments with thresholds measured in a sound-treated booth. 149 children (54% female) with an average age of 6.9 yr (SD = 0.6; range = 5-8). Average difference between the booth and natural environment thresholds was 0.0 dB (SD = 3.6) for air conduction and 0.1 dB (SD = 3.1) for bone conduction. Average absolute difference between the booth and natural environment was 2.1 dB (SD = 2.9) for air conduction and 1.6 dB (SD = 2.7) for bone conduction. Almost all air- (96%) and bone-conduction (97%) threshold comparisons between the natural and booth test environments were within 0 to 5 dB. No statistically significant differences between thresholds recorded in the natural and booth environments for air- and bone-conduction audiometry were found (p > 0.01). Diagnostic air- and bone-conduction audiometry in schools, without a sound-treated room, is possible with sufficient earphone attenuation and real-time monitoring of environmental noise. Audiological diagnosis on-site for school screening may address concerns of false-positive referrals and poor follow-up compliance and allow for direct referral to audiological and/or medical intervention. American Academy of Audiology.

  1. Relative and Absolute Error Control in a Finite-Difference Method Solution of Poisson's Equation

    ERIC Educational Resources Information Center

    Prentice, J. S. C.

    2012-01-01

    An algorithm for error control (absolute and relative) in the five-point finite-difference method applied to Poisson's equation is described. The algorithm is based on discretization of the domain of the problem by means of three rectilinear grids, each of different resolution. We discuss some hardware limitations associated with the algorithm,…

  2. Landsat-7 ETM+: 12 years On-Orbit Reflective-Band Radiometric Performance

    NASA Technical Reports Server (NTRS)

    Markham, Brian L.; Haque, O.; Barsi, Julia A.; Micijevic, E.; Helder, Dennis H.; Thome, Kurtis J.; Aaron, David; Czapla-Myers, J.

    2011-01-01

    The Landsat-7 ETM+ sensor has been operating on orbit for more than 12 years and characterizations of its performance have been ongoing over this period. In general, the radiometric performance of the instrument has been remarkably stable: (1) Noise performance has degraded by 2% or less overall, with a few detectors displaying step changes in noise of 2% or less, (2) Coherent noise frequencies and magnitudes have generally been stable, though the within-scan amplitude variation of the 20kHz noise in bands 1 and 8 disappeared with the failure of the scan line corrector and a new similar frequency noise (now about 18kHz) has appeared in two detectors in band 5 and increased in magnitude with time, (3) Bias stability has been better than 0.25 DN out of a normal value of 15 DN in high gain, (4) Relative gains, the differences in response between the detectors in the band, have generally changed by 0.1% or less over the mission, with the exception of a few detectors with a step response change of 1% or less and (5) Gain stability averaged across all detectors in a band, which is related to the stability of the absolute calibration, has been more stable than the techniques used to measure it. Due to the inability to confirm changes in the gain (beyond a few detectors that have been corrected back to the band average), ETM+ reflective band data continues to be calibrated with the pre-launch measured gains. In the worst case some bands may have changed as much as 2% in uncompensated absolute calibration over the 12 years.

  3. Forecasting mortality of road traffic injuries in China using seasonal autoregressive integrated moving average model.

    PubMed

    Zhang, Xujun; Pang, Yuanyuan; Cui, Mengjing; Stallones, Lorann; Xiang, Huiyun

    2015-02-01

    Road traffic injuries have become a major public health problem in China. This study aimed to develop statistical models for predicting road traffic deaths and to analyze seasonality of deaths in China. A seasonal autoregressive integrated moving average (SARIMA) model was used to fit the data from 2000 to 2011. Akaike Information Criterion, Bayesian Information Criterion, and mean absolute percentage error were used to evaluate the constructed models. Autocorrelation function and partial autocorrelation function of residuals and Ljung-Box test were used to compare the goodness-of-fit between the different models. The SARIMA model was used to forecast monthly road traffic deaths in 2012. The seasonal pattern of road traffic mortality data was statistically significant in China. SARIMA (1, 1, 1) (0, 1, 1)12 model was the best fitting model among various candidate models; the Akaike Information Criterion, Bayesian Information Criterion, and mean absolute percentage error were -483.679, -475.053, and 4.937, respectively. Goodness-of-fit testing showed nonautocorrelations in the residuals of the model (Ljung-Box test, Q = 4.86, P = .993). The fitted deaths using the SARIMA (1, 1, 1) (0, 1, 1)12 model for years 2000 to 2011 closely followed the observed number of road traffic deaths for the same years. The predicted and observed deaths were also very close for 2012. This study suggests that accurate forecasting of road traffic death incidence is possible using SARIMA model. The SARIMA model applied to historical road traffic deaths data could provide important evidence of burden of road traffic injuries in China. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Landsat-7 ETM+: 12 years on-orbit reflective-band radiometric performance

    USGS Publications Warehouse

    Markham, B.L.; Haque, M.O.; Barsi, J.A.; Micijevic, E.; Helder, D.L.; Thome, K.J.; Aaron, David; Czapla-Myers, J. S.

    2012-01-01

    The Landsat-7 ETM+ sensor has been operating on orbit for more than 12 years, and characterizations of its performance have been ongoing over this period. In general, the radiometric performance of the instrument has been remarkably stable: 1) noise performance has degraded by 2% or less overall, with a few detectors displaying step changes in noise of 2% or less; 2) coherent noise frequencies and magnitudes have generally been stable, though the within-scan amplitude variation of the 20 kHz noise in bands 1 and 8 disappeared with the failure of the scan line corrector and a new similar frequency noise (now about 18 kHz) has appeared in two detectors in band 5 and increased in magnitude with time; 3) bias stability has been better than 0.25 DN out of a normal value of 15 DN in high gain; 4) relative gains, the differences in response between the detectors in the band, have generally changed by 0.1% or less over the mission, with the exception of a few detectors with a step response change of 1% or less; and 5) gain stability averaged across all detectors in a band, which is related to the stability of the absolute calibration, has been more stable than the techniques used to measure it. Due to the inability to confirm changes in the gain (beyond a few detectors that have been corrected back to the band average), ETM+ reflective band data continues to be calibrated with the prelaunch measured gains. In the worst case, some bands may have changed as much as 2% in uncompensated absolute calibration over the 12 years.

  5. The Type Ia Supernova Color-Magnitude Relation and Host Galaxy Dust: A Simple Hierarchical Bayesian Model

    NASA Astrophysics Data System (ADS)

    Mandel, Kaisey S.; Scolnic, Daniel M.; Shariff, Hikmatali; Foley, Ryan J.; Kirshner, Robert P.

    2017-06-01

    Conventional Type Ia supernova (SN Ia) cosmology analyses currently use a simplistic linear regression of magnitude versus color and light curve shape, which does not model intrinsic SN Ia variations and host galaxy dust as physically distinct effects, resulting in low color-magnitude slopes. We construct a probabilistic generative model for the dusty distribution of extinguished absolute magnitudes and apparent colors as the convolution of an intrinsic SN Ia color-magnitude distribution and a host galaxy dust reddening-extinction distribution. If the intrinsic color-magnitude (M B versus B - V) slope {β }{int} differs from the host galaxy dust law R B , this convolution results in a specific curve of mean extinguished absolute magnitude versus apparent color. The derivative of this curve smoothly transitions from {β }{int} in the blue tail to R B in the red tail of the apparent color distribution. The conventional linear fit approximates this effective curve near the average apparent color, resulting in an apparent slope {β }{app} between {β }{int} and R B . We incorporate these effects into a hierarchical Bayesian statistical model for SN Ia light curve measurements, and analyze a data set of SALT2 optical light curve fits of 248 nearby SNe Ia at z< 0.10. The conventional linear fit gives {β }{app}≈ 3. Our model finds {β }{int}=2.3+/- 0.3 and a distinct dust law of {R}B=3.8+/- 0.3, consistent with the average for Milky Way dust, while correcting a systematic distance bias of ˜0.10 mag in the tails of the apparent color distribution. Finally, we extend our model to examine the SN Ia luminosity-host mass dependence in terms of intrinsic and dust components.

  6. Absolute change in fasting plasma glucose over 12 months is associated with 2-year and 5-year major adverse cardiovascular events in patients with drug-eluting stent implants.

    PubMed

    Kang, Dong Oh; Seo, Hong Seog; Choi, Byung Geol; Lee, Eunmi; Kim, Ji Park; Lee, Sun Ki; Im, Sung Il; Na, Jin Oh; Choi, Cheol Ung; Lim, Hong Euy; Kim, Jin Won; Kim, Eung Ju; Rha, Seung-Woon; Park, Chang Gyu; Oh, Dong Joo

    2015-01-20

    Major adverse cardiovascular events (MACEs) in patients with or without cardiovascular disease (CVD) are greatly affected by various factors associated with metabolism and inflammation. To determine which clinical parameters at treatment are associated with the development of 2-year and 5-year MACEs in high-risk patients with CVD who have undergone drug-eluting stent (DES) implantation. The present study involved a total of 432 patients who underwent percutaneous coronary intervention with DES. Variables representing the average and absolute amount of change in clinical parameters over the 12-month follow-up were assessed for association with 2-year and 5-year development of MACE. The study population was divided into quartiles for the variable showing the highest correlation to MACE development. Estimated incidence of 2-year and 5-year MACEs for each of the quartiles was determined by survival curve analysis, and subgroup analysis was performed for patients with diabetes and statin users. Absolute change in fasting plasma glucose (FPG) over 12 months showed the highest correlation with 2-year and 5-year MACE development. The estimated incidence of MACE increased with increasing quartiles for absolute change in FPG. The association between absolute change in FPG and MACE development exhibited a stronger relationship for the specific subgroups of patients with diabetes and statin users. Increases and decreases in FPG had a comparable contribution to MACE development. A greater absolute change in FPG over 12 months post-PCI is an independent risk factor for 2-year and 5-year MACE development in DES-implanted patients, especially in the diabetes and statin users. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Aged Riverine Particulate Organic Carbon in Four UK Catchments

    NASA Astrophysics Data System (ADS)

    Adams, Jessica; Tipping, Edward; Bryant, Charlotte; Helliwell, Rachel; Toberman, Hannah; Quinton, John

    2016-04-01

    The riverine transport of particulate organic matter (POM) is a significant flux in the carbon cycle, and affects macronutrients and contaminants. We used radiocarbon to characterise POM at 9 riverine sites of four UK catchments (Avon, Conwy, Dee, Ribble) over a one-year period. High-discharge samples were collected on three or four occasions at each site. Suspended particulate matter (SPM) was obtained by centrifugation, and the samples were analysed for carbon isotopes. Concentrations of SPM and SPM organic carbon (OC) contents were also determined, and were found to have a significant negative correlation. For the 7 rivers draining predominantly rural catchments, PO14C values, expressed as percent modern carbon absolute (pMC), varied little among samplings at each site, and there was no significant difference in the average values among the sites. The overall average PO14C value for the 7 sites of 91.2 pMC corresponded to an average age of 680 14C years, but this value arises from the mixing of differently-aged components, and therefore significant amounts of organic matter older than the average value are present in the samples. Although topsoil erosion is probably the major source of the riverine POM, the average PO14C value is appreciably lower than topsoil values (which are typically 100 pMC). This is most likely explained by inputs of older subsoil OC from bank erosion, or the preferential loss of high-14C topsoil organic matter by mineralisation during riverine transport. The significantly lower average PO14C of samples from the River Calder (76.6 pMC), can be ascribed to components containing little or no radiocarbon, derived either from industrial sources or historical coal mining, and this effect is also seen in the River Ribble, downstream of its confluence with the Calder. At the global scale, the results significantly expand available information for PO14C in rivers draining catchments with low erosion rates.

  8. Method For Detecting The Presence Of A Ferromagnetic Object

    DOEpatents

    Roybal, Lyle G.

    2000-11-21

    A method for detecting a presence or an absence of a ferromagnetic object within a sensing area may comprise the steps of sensing, during a sample time, a magnetic field adjacent the sensing area; producing surveillance data representative of the sensed magnetic field; determining an absolute value difference between a maximum datum and a minimum datum comprising the surveillance data; and determining whether the absolute value difference has a positive or negative sign. The absolute value difference and the corresponding positive or negative sign thereof forms a representative surveillance datum that is indicative of the presence or absence in the sensing area of the ferromagnetic material.

  9. Global Intercomparison of 12 Land Surface Heat Flux Estimates

    NASA Technical Reports Server (NTRS)

    Jimenez, C.; Prigent, C.; Mueller, B.; Seneviratne, S. I.; McCabe, M. F.; Wood, E. F.; Rossow, W. B.; Balsamo, G.; Betts, A. K.; Dirmeyer, P. A.; hide

    2011-01-01

    A global intercomparison of 12 monthly mean land surface heat flux products for the period 1993-1995 is presented. The intercomparison includes some of the first emerging global satellite-based products (developed at Paris Observatory, Max Planck Institute for Biogeochemistry, University of California Berkeley, University of Maryland, and Princeton University) and examples of fluxes produced by reanalyses (ERA-Interim, MERRA, NCEP-DOE) and off-line land surface models (GSWP-2, GLDAS CLM/ Mosaic/Noah). An intercomparison of the global latent heat flux (Q(sub le)) annual means shows a spread of approx 20 W/sq m (all-product global average of approx 45 W/sq m). A similar spread is observed for the sensible (Q(sub h)) and net radiative (R(sub n)) fluxes. In general, the products correlate well with each other, helped by the large seasonal variability and common forcing data for some of the products. Expected spatial distributions related to the major climatic regimes and geographical features are reproduced by all products. Nevertheless, large Q(sub le)and Q(sub h) absolute differences are also observed. The fluxes were spatially averaged for 10 vegetation classes. The larger Q(sub le) differences were observed for the rain forest but, when normalized by mean fluxes, the differences were comparable to other classes. In general, the correlations between Q(sub le) and R(sub n) were higher for the satellite-based products compared with the reanalyses and off-line models. The fluxes were also averaged for 10 selected basins. The seasonality was generally well captured by all products, but large differences in the flux partitioning were observed for some products and basins.

  10. A two-step ionospheric modeling algorithm considering the impact of GLONASS pseudo-range inter-channel biases

    NASA Astrophysics Data System (ADS)

    Zhang, Rui; Yao, Yi-bin; Hu, Yue-ming; Song, Wei-wei

    2017-12-01

    The Global Navigation Satellite System presents a plausible and cost-effective way of computing the total electron content (TEC). But TEC estimated value could be seriously affected by the differential code biases (DCB) of frequency-dependent satellites and receivers. Unlike GPS and other satellite systems, GLONASS adopts a frequency-division multiplexing access mode to distinguish different satellites. This strategy leads to different wavelengths and inter-frequency biases (IFBs) for both pseudo-range and carrier phase observations, whose impacts are rarely considered in ionospheric modeling. We obtained observations from four groups of co-stations to analyze the characteristics of the GLONASS receiver P1P2 pseudo-range IFB with a double-difference method. The results showed that the GLONASS P1P2 pseudo-range IFB remained stable for a period of time and could catch up to several meters, which cannot be absorbed by the receiver DCB during ionospheric modeling. Given the characteristics of the GLONASS P1P2 pseudo-range IFB, we proposed a two-step ionosphere modeling method with the priori IFB information. The experimental analysis showed that the new algorithm can effectively eliminate the adverse effects on ionospheric model and hardware delay parameters estimation in different space environments. During high solar activity period, compared to the traditional GPS + GLONASS modeling algorithm, the absolute average deviation of TEC decreased from 2.17 to 2.07 TECu (TEC unit); simultaneously, the average RMS of GPS satellite DCB decreased from 0.225 to 0.219 ns, and the average deviation of GLONASS satellite DCB decreased from 0.253 to 0.113 ns with a great improvement in over 55%.

  11. Color accuracy and reproducibility in whole slide imaging scanners

    PubMed Central

    Shrestha, Prarthana; Hulsken, Bas

    2014-01-01

    Abstract We propose a workflow for color reproduction in whole slide imaging (WSI) scanners, such that the colors in the scanned images match to the actual slide color and the inter-scanner variation is minimum. We describe a new method of preparation and verification of the color phantom slide, consisting of a standard IT8-target transmissive film, which is used in color calibrating and profiling the WSI scanner. We explore several International Color Consortium (ICC) compliant techniques in color calibration/profiling and rendering intents for translating the scanner specific colors to the standard display (sRGB) color space. Based on the quality of the color reproduction in histopathology slides, we propose the matrix-based calibration/profiling and absolute colorimetric rendering approach. The main advantage of the proposed workflow is that it is compliant to the ICC standard, applicable to color management systems in different platforms, and involves no external color measurement devices. We quantify color difference using the CIE-DeltaE2000 metric, where DeltaE values below 1 are considered imperceptible. Our evaluation on 14 phantom slides, manufactured according to the proposed method, shows an average inter-slide color difference below 1 DeltaE. The proposed workflow is implemented and evaluated in 35 WSI scanners developed at Philips, called the Ultra Fast Scanners (UFS). The color accuracy, measured as DeltaE between the scanner reproduced colors and the reference colorimetric values of the phantom patches, is improved on average to 3.5 DeltaE in calibrated scanners from 10 DeltaE in uncalibrated scanners. The average inter-scanner color difference is found to be 1.2 DeltaE. The improvement in color performance upon using the proposed method is apparent with the visual color quality of the tissue scans. PMID:26158041

  12. Absolute position calculation for a desktop mobile rehabilitation robot based on three optical mouse sensors.

    PubMed

    Zabaleta, Haritz; Valencia, David; Perry, Joel; Veneman, Jan; Keller, Thierry

    2011-01-01

    ArmAssist is a wireless robot for post stroke upper limb rehabilitation. Knowing the position of the arm is essential for any rehabilitation device. In this paper, we describe a method based on an artificial landmark navigation system. The navigation system uses three optical mouse sensors. This enables the building of a cheap but reliable position sensor. Two of the sensors are the data source for odometry calculations, and the third optical mouse sensor takes very low resolution pictures of a custom designed mat. These pictures are processed by an optical symbol recognition algorithm which will estimate the orientation of the robot and recognize the landmarks placed on the mat. The data fusion strategy is described to detect the misclassifications of the landmarks in order to fuse only reliable information. The orientation given by the optical symbol recognition (OSR) algorithm is used to improve significantly the odometry and the recognition of the landmarks is used to reference the odometry to a absolute coordinate system. The system was tested using a 3D motion capture system. With the actual mat configuration, in a field of motion of 710 × 450 mm, the maximum error in position estimation was 49.61 mm with an average error of 36.70 ± 22.50 mm. The average test duration was 36.5 seconds and the average path length was 4173 mm.

  13. The Relation between the Absolute Level of Parenting and Differential Parental Treatment with Adolescent Siblings' Adjustment

    ERIC Educational Resources Information Center

    Tamrouti-Makkink, Ilse D.; Dubas, Judith Semon; Gerris, Jan R. M.; van Aken, Marcel A. G.

    2004-01-01

    Background: The present study extends existing studies on the role of differential parental treatment in explaining individual differences in adolescent problem behaviors above the absolute level of parenting and clarifies the function of gender of the child, birth rank and gender constellation of the sibling dyads. Method: The absolute level of…

  14. A Group Decision Framework with Intuitionistic Preference Relations and Its Application to Low Carbon Supplier Selection.

    PubMed

    Tong, Xiayu; Wang, Zhou-Jing

    2016-09-19

    This article develops a group decision framework with intuitionistic preference relations. An approach is first devised to rectify an inconsistent intuitionistic preference relation to derive an additive consistent one. A new aggregation operator, the so-called induced intuitionistic ordered weighted averaging (IIOWA) operator, is proposed to aggregate individual intuitionistic fuzzy judgments. By using the mean absolute deviation between the original and rectified intuitionistic preference relations as an order inducing variable, the rectified consistent intuitionistic preference relations are aggregated into a collective preference relation. This treatment is presumably able to assign different weights to different decision-makers' judgments based on the quality of their inputs (in terms of consistency of their original judgments). A solution procedure is then developed for tackling group decision problems with intuitionistic preference relations. A low carbon supplier selection case study is developed to illustrate how to apply the proposed decision model in practice.

  15. A Group Decision Framework with Intuitionistic Preference Relations and Its Application to Low Carbon Supplier Selection

    PubMed Central

    Tong, Xiayu; Wang, Zhou-Jing

    2016-01-01

    This article develops a group decision framework with intuitionistic preference relations. An approach is first devised to rectify an inconsistent intuitionistic preference relation to derive an additive consistent one. A new aggregation operator, the so-called induced intuitionistic ordered weighted averaging (IIOWA) operator, is proposed to aggregate individual intuitionistic fuzzy judgments. By using the mean absolute deviation between the original and rectified intuitionistic preference relations as an order inducing variable, the rectified consistent intuitionistic preference relations are aggregated into a collective preference relation. This treatment is presumably able to assign different weights to different decision-makers’ judgments based on the quality of their inputs (in terms of consistency of their original judgments). A solution procedure is then developed for tackling group decision problems with intuitionistic preference relations. A low carbon supplier selection case study is developed to illustrate how to apply the proposed decision model in practice. PMID:27657097

  16. A simple model to predict the biodiesel blend density as simultaneous function of blend percent and temperature.

    PubMed

    Gaonkar, Narayan; Vaidya, R G

    2016-05-01

    A simple method to estimate the density of biodiesel blend as simultaneous function of temperature and volume percent of biodiesel is proposed. Employing the Kay's mixing rule, we developed a model and investigated theoretically the density of different vegetable oil biodiesel blends as a simultaneous function of temperature and volume percent of biodiesel. Key advantage of the proposed model is that it requires only a single set of density values of components of biodiesel blends at any two different temperatures. We notice that the density of blend linearly decreases with increase in temperature and increases with increase in volume percent of the biodiesel. The lower values of standard estimate of error (SEE = 0.0003-0.0022) and absolute average deviation (AAD = 0.03-0.15 %) obtained using the proposed model indicate the predictive capability. The predicted values found good agreement with the recent available experimental data.

  17. A dual-adaptive support-based stereo matching algorithm

    NASA Astrophysics Data System (ADS)

    Zhang, Yin; Zhang, Yun

    2017-07-01

    Many stereo matching algorithms use fixed color thresholds and a rigid cross skeleton to segment supports (viz., Cross method), which, however, does not work well for different images. To address this issue, this paper proposes a novel dual adaptive support (viz., DAS)-based stereo matching method, which uses both appearance and shape information of a local region to segment supports automatically, and, then, integrates the DAS-based cost aggregation with the absolute difference plus census transform cost, scanline optimization and disparity refinement to develop a stereo matching system. The performance of the DAS method is also evaluated in the Middlebury benchmark and by comparing with the Cross method. The results show that the average error for the DAS method 25.06% lower than that for the Cross method, indicating that the proposed method is more accurate, with fewer parameters and suitable for parallel computing.

  18. Research on spectrum broadening covering visible light of a fiber femtosecond optical frequency comb for absolute frequency measurement

    NASA Astrophysics Data System (ADS)

    Xing, Shuai; Wu, Tengfei; Li, Shuyi; Xia, Chuanqing; Han, Jibo; Zhang, Lei; Zhao, Chunbo

    2018-03-01

    As a bridge connecting microwave frequency and optical frequency, femtosecond laser has important significance in optical frequency measurement. Compared with the traditional Ti-sapphire femtosecond optical frequency comb, with the advantages of compact structure, strong anti-interference ability and low cost, the fiber femtosecond optical frequency comb has a wider application prospect. An experiment of spectrum broadening in a highly nonlinear photonic crystal fiber pumped by an Er-fiber mode-locked femtosecond laser is studied in this paper. Based on optical amplification and frequency doubling, the central wavelength of the output spectrum is 780nm and the average power is 232mW. With the femtosecond pulses coupled into two different photonic crystal fibers, the coverage of visible spectrum is up to 500nm-960nm. The spectral shape and width can be optimized by changing the polarization state for satisfying the requirments of different optical frequencies measurement.

  19. The systolic blood pressure difference between arms and cardiovascular disease in the Framingham Heart Study.

    PubMed

    Weinberg, Ido; Gona, Philimon; O'Donnell, Christopher J; Jaff, Michael R; Murabito, Joanne M

    2014-03-01

    An increased interarm systolic blood pressure difference is an easily determined physical examination finding. The relationship between interarm systolic blood pressure difference and risk of future cardiovascular disease is uncertain. We described the prevalence and risk factor correlates of interarm systolic blood pressure difference in the Framingham Heart Study (FHS) original and offspring cohorts and examined the association between interarm systolic blood pressure difference and incident cardiovascular disease and all-cause mortality. An increased interarm systolic blood pressure difference was defined as ≥ 10 mm Hg using the average of initial and repeat blood pressure measurements obtained in both arms. Participants were followed through 2010 for incident cardiovascular disease events. Multivariable Cox proportional hazards regression analyses were performed to investigate the effect of interarm systolic blood pressure difference on incident cardiovascular disease. We examined 3390 (56.3% female) participants aged 40 years and older, free of cardiovascular disease at baseline, mean age of 61.1 years, who attended a FHS examination between 1991 and 1994 (original cohort) and from 1995 to 1998 (offspring cohort). The mean absolute interarm systolic blood pressure difference was 4.6 mm Hg (range 0-78). Increased interarm systolic blood pressure difference was present in 317 (9.4%) participants. The median follow-up time was 13.3 years, during which time 598 participants (17.6%) experienced a first cardiovascular event, including 83 (26.2%) participants with interarm systolic blood pressure difference ≥ 10 mm Hg. Compared with those with normal interarm systolic blood pressure difference, participants with an elevated interarm systolic blood pressure difference were older (63.0 years vs 60.9 years), had a greater prevalence of diabetes mellitus (13.3% vs 7.5%,), higher systolic blood pressure (136.3 mm Hg vs 129.3 mm Hg), and a higher total cholesterol level (212.1 mg/dL vs 206.5 mg/dL). Interarm systolic blood pressure difference was associated with a significantly increased hazard of incident cardiovascular events in the multivariable adjusted model (hazard ratio 1.38; 95% CI, 1.09-1.75). For each 1-SD-unit increase in absolute interarm systolic blood pressure difference, the hazard ratio for incident cardiovascular events was 1.07 (95% CI, 1.00-1.14) in the fully adjusted model. There was no such association with mortality (hazard ratio 1.02; 95% CI 0.76-1.38). In this community-based cohort, an interarm systolic blood pressure difference is common and associated with a significant increased risk for future cardiovascular events, even when the absolute difference in arm systolic blood pressure is modest. These findings support research to expand clinical use of this simple measurement. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Mind and body therapy for fibromyalgia.

    PubMed

    Theadom, Alice; Cropley, Mark; Smith, Helen E; Feigin, Valery L; McPherson, Kathryn

    2015-04-09

    Mind-body interventions are based on the holistic principle that mind, body and behaviour are all interconnected. Mind-body interventions incorporate strategies that are thought to improve psychological and physical well-being, aim to allow patients to take an active role in their treatment, and promote people's ability to cope. Mind-body interventions are widely used by people with fibromyalgia to help manage their symptoms and improve well-being. Examples of mind-body therapies include psychological therapies, biofeedback, mindfulness, movement therapies and relaxation strategies. To review the benefits and harms of mind-body therapies in comparison to standard care and attention placebo control groups for adults with fibromyalgia, post-intervention and at three and six month follow-up. Electronic searches of the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE (Ovid), EMBASE (Ovid), PsycINFO (Ovid), AMED (EBSCO) and CINAHL (Ovid) were conducted up to 30 October 2013. Searches of reference lists were conducted and authors in the field were contacted to identify additional relevant articles. All relevant randomised controlled trials (RCTs) of mind-body interventions for adults with fibromyalgia were included. Two authors independently selected studies, extracted the data and assessed trials for low, unclear or high risk of bias. Any discrepancy was resolved through discussion and consensus. Continuous outcomes were analysed using mean difference (MD) where the same outcome measure and scoring method was used and standardised mean difference (SMD) where different outcome measures were used. For binary data standard estimation of the risk ratio (RR) and its 95% confidence interval (CI) was used. Seventy-four papers describing 61 trials were identified, with 4234 predominantly female participants. The nature of fibromyalgia varied from mild to severe across the study populations. Twenty-six studies were classified as having a low risk of bias for all domains assessed. The findings of mind-body therapies compared with usual care were prioritised.There is low quality evidence that in comparison to usual care controls psychological therapies have favourable effects on physical functioning (SMD -0.4, 95% CI -0.6 to -0.3, -7.5% absolute change, 2 point shift on a 0 to 100 scale), pain (SMD -0.3, 95% CI -0.5 to -0.2, -3.5% absolute change, 2 point shift on a 0 to 100 scale) and mood (SMD -0.5, 95% CI -0.6 to -0.3, -4.8% absolute change, 3 point shift on a 20 to 80 scale). There is very low quality evidence of more withdrawals in the psychological therapy group in comparison to usual care controls (RR 1.38, 95% CI 1.12 to 1.69, 6% absolute risk difference). There is lack of evidence of a difference between the number of adverse events in the psychological therapy and control groups (RR 0.38, 95% CI 0.06 to 2.50, 4% absolute risk difference).There was very low quality evidence that biofeedback in comparison to usual care controls had an effect on physical functioning (SMD -0.1, 95% CI -0.4 to 0.3, -1.2% absolute change, 1 point shift on a 0 to 100 scale), pain (SMD -2.6, 95% CI -91.3 to 86.1, -2.6% absolute change) and mood (SMD 0.1, 95% CI -0.3 to 0.5, 1.9% absolute change, less than 1 point shift on a 0 to 90 scale) post-intervention. In view of the quality of evidence we cannot be certain that biofeedback has a little or no effect on these outcomes. There was very low quality evidence that biofeedback led to more withdrawals from the study (RR 4.08, 95% CI 1.43 to 11.62, 20% absolute risk difference). No adverse events were reported.There was no advantage observed for mindfulness in comparison to usual care for physical functioning (SMD -0.3, 95% CI -0.6 to 0.1, -4.8% absolute change, 4 point shift on a scale 0 to 100), pain (SMD -0.1, CI -0.4 to 0.3, -1.3% absolute change, less than 1 point shift on a 0 to 10 scale), mood (SMD -0.2, 95% CI -0.5 to 0.0, -3.7% absolute change, 2 point shift on a 20 to 80 scale) or withdrawals (RR 1.07, 95% CI 0.67 to 1.72, 2% absolute risk difference) between the two groups post-intervention. However, the quality of the evidence was very low for pain and moderate for mood and number of withdrawals. No studies reported any adverse events.Very low quality evidence revealed that movement therapies in comparison to usual care controls improved pain (MD -2.3, CI -4.2 to -0.4, -23% absolute change) and mood (MD -9.8, 95% CI -18.5 to -1.2, -16.4% absolute change) post-intervention. There was no advantage for physical functioning (SMD -0.2, 95% CI -0.5 to 0.2, -3.4% absolute change, 2 point shift on a 0 to 100 scale), participant withdrawals (RR 1.95, 95% CI 1.13 to 3.38, 11% absolute difference) or adverse events (RR 4.62, 95% CI 0.23 to 93.92, 4% absolute risk difference) between the two groups, however rare adverse events may include worsening of pain.Low quality evidence revealed that relaxation based therapies in comparison to usual care controls showed an advantage for physical functioning (MD -8.3, 95% CI -10.1 to -6.5, -10.4% absolute change) and pain (SMD -1.0, 95% CI -1.6 to -0.5, -3.5% absolute change, 2 point shift on a 0 to 78 scale) but not for mood (SMD -4.4, CI -14.5 to 5.6, -7.4% absolute change) post-intervention. There was no difference between the groups for number of withdrawals (RR 4.40, 95% CI 0.59 to 33.07, 31% absolute risk difference) and no adverse events were reported. Psychological interventions therapies may be effective in improving physical functioning, pain and low mood for adults with fibromyalgia in comparison to usual care controls but the quality of the evidence is low. Further research on the outcomes of therapies is needed to determine if positive effects identified post-intervention are sustained. The effectiveness of biofeedback, mindfulness, movement therapies and relaxation based therapies remains unclear as the quality of the evidence was very low or low. The small number of trials and inconsistency in the use of outcome measures across the trials restricted the analysis.

  1. Linking Comparisons of Absolute Gravimeters: A Proof of Concept for a new Global Absolute Gravity Reference System.

    NASA Astrophysics Data System (ADS)

    Wziontek, H.; Palinkas, V.; Falk, R.; Vaľko, M.

    2016-12-01

    Since decades, absolute gravimeters are compared on a regular basis on an international level, starting at the International Bureau for Weights and Measures (BIPM) in 1981. Usually, these comparisons are based on constant reference values deduced from all accepted measurements acquired during the comparison period. Temporal changes between comparison epochs are usually not considered. Resolution No. 2, adopted by IAG during the IUGG General Assembly in Prague 2015, initiates the establishment of a Global Absolute Gravity Reference System based on key comparisons of absolute gravimeters (AG) under the International Committee for Weights and Measures (CIPM) in order to establish a common level in the microGal range. A stable and unique reference frame can only be achieved, if different AG are taking part in different kind of comparisons. Systematic deviations between the respective comparison reference values can be detected, if the AG can be considered stable over time. The continuous operation of superconducting gravimeters (SG) on selected stations further supports the temporal link of comparison reference values by establishing a reference function over time. By a homogenous reprocessing of different comparison epochs and including AG and SG time series at selected stations, links between several comparisons will be established and temporal comparison reference functions will be derived. By this, comparisons on a regional level can be traced to back to the level of key comparisons, providing a reference for other absolute gravimeters. It will be proved and discussed, how such a concept can be used to support the future absolute gravity reference system.

  2. Improved performance of semiconductor laser tracking frequency gauge

    NASA Astrophysics Data System (ADS)

    Kaplan, D. M.; Roberts, T. J.; Phillips, J. D.; Reasenberg, R. D.

    2018-03-01

    We describe new results from the semiconductor-laser tracking frequency gauge, an instrument that can perform sub-picometer distance measurements and has applications in gravity research and in space-based astronomical instruments proposed for the study of light from extrasolar planets. Compared with previous results, we have improved incremental distance accuracy by a factor of two, to 0.9 pm in 80 s averaging time, and absolute distance accuracy by a factor of 20, to 0.17 μm in 1000 s. After an interruption of operation of a tracking frequency gauge used to control a distance, it is now possible, using a nonresonant measurement interferometer, to restore the distance to picometer accuracy by combining absolute and incremental distance measurements.

  3. Superslow relaxation in identical phase oscillators with random and frustrated interactions

    NASA Astrophysics Data System (ADS)

    Daido, H.

    2018-04-01

    This paper is concerned with the relaxation dynamics of a large population of identical phase oscillators, each of which interacts with all the others through random couplings whose parameters obey the same Gaussian distribution with the average equal to zero and are mutually independent. The results obtained by numerical simulation suggest that for the infinite-size system, the absolute value of Kuramoto's order parameter exhibits superslow relaxation, i.e., 1/ln t as time t increases. Moreover, the statistics on both the transient time T for the system to reach a fixed point and the absolute value of Kuramoto's order parameter at t = T are also presented together with their distribution densities over many realizations of the coupling parameters.

  4. Automatic solar image motion measurements. [electronic disk flux monitoring

    NASA Technical Reports Server (NTRS)

    Colgate, S. A.; Moore, E. P.

    1975-01-01

    The solar seeing image motion has been monitored electronically and absolutely with a 25 cm telescope at three sites along the ridge at the southern end of the Magdalena Mountains west of Socorro, New Mexico. The uncorrelated component of the variations of the optical flux from two points at opposite limbs of the solar disk was continually monitored in 3 frequencies centered at 0.3, 3 and 30 Hz. The frequency band of maximum signal centered at 3 Hz showed the average absolute value of image motion to be somewhat less than 2sec. The observer estimates of combined blurring and image motion were well correlated with electronically measured image motion, but the observer estimates gave a factor 2 larger value.

  5. Absolute intensities and self-, N2-, and air-broadened Lorentz halfwidths for selected lines in the nu3 band of (C-12)H3D from measurements with a tunable diode laser spectrometer

    NASA Technical Reports Server (NTRS)

    Malathy Devi, V.; Benner, D. C.; Rinsland, C. P.; Smith, M. A. H.; Thakur, K. B.

    1986-01-01

    Absolute intensities and self-, air- and N2-broadened half-widths have been determined for the first time for individual lines in the nu3(A1) band of (C-12)H3D near 7.6 microns from measurements of individual vibration-rotation lines using a tunable diode laser spectrometer. The intensity measurements are believed to be accurate to within three percent. Within experimental uncertainties, equal broadening efficiencies are found for both air and nitrogen. Self-broadened half-widths determined for three transitions yield an average half-width value of 0.803 + or -0.0010/cm/atm at 296 K.

  6. Pulse energy measurement at the SXR instrument

    DOE PAGES

    Moeller, Stefan; Brown, Garth; Dakovski, Georgi; ...

    2015-04-14

    A gas monitor detector was implemented and characterized at the Soft X-ray Research (SXR) instrument to measure the average, absolute and pulse-resolved photon flux of the LCLS beam in the energy range between 280 and 2000 eV. The detector is placed after the monochromator and addresses the need to provide reliable absolute pulse energy as well as pulse-resolved measurements for the various experiments at this instrument. This detector provides a reliable non-invasive measurement for determining flux levels on the samples in the downstream experimental chamber and for optimizing signal levels of secondary detectors and for the essential need of datamore » normalization. The design, integration into the instrument and operation are described, and examples of its performance are given.« less

  7. Educational inequality in cardiovascular disease depends on diagnosis: A nationwide register based study from Denmark.

    PubMed

    Christensen, Anne V; Koch, Mette B; Davidsen, Michael; Jensen, Gorm B; Andersen, Lisbeth V; Juel, Knud

    2016-05-01

    Social inequality is present in the morbidity as well as the mortality of cardiovascular diseases. This paper aims to quantify and compare the level of educational inequality across different cardiovascular diagnoses. Register based study. Comparison of the extent of inequality across different cardiovascular diagnoses requires a measure of inequality which is comparable across subgroups with different educational distributions. The slope index of inequality and the relative index of inequality were applied for measuring inequalities in incidence of six cardiovascular diagnoses: ischaemic heart disease, acute myocardial infarction, valvular heart disease, congestive heart failure, atrial fibrillation and stroke in the period 2005-2009. All individuals in the general Danish population aged 35-84 years were followed in national registers regarding hospitalisation, death and education from 1985 to 2009 (annual average of 2.9 million people) to define incident cases. Marked educational inequality was found in the incidence of ischaemic heart disease, acute myocardial infarction, heart failure and stroke (relative index of inequality: 0.37 (95% confidence interval 0.34; 0.40) to 0.60 (0.57; 0.63), absolute index of inequality: -241 (-254.4; -227.4) to -37 (-42.7; -31.1)) while inequality in atrial fibrillation and, in particular, in valvular heart disease was small and insignificant (relative index of inequality: 0.57 (0.49; 0.65) to 0.97 (0.88; 1.08), absolute index of inequality: -29 (-35.1; -21.9) to -1 (-4.8; -3.8)). The degree of educational inequality in cardiovascular diseases depends on the diagnosis, with the highest inequality in ischaemic heart disease, acute myocardial infarction, heart failure and stroke. Small differences were found between men and women. © The European Society of Cardiology 2015.

  8. How Do Various Maize Crop Models Vary in Their Responses to Climate Change Factors?

    NASA Technical Reports Server (NTRS)

    Bassu, Simona; Brisson, Nadine; Grassini, Patricio; Durand, Jean-Louis; Boote, Kenneth; Lizaso, Jon; Jones, James W.; Rosenzweig, Cynthia; Ruane, Alex C.; Adam, Myriam; hide

    2014-01-01

    Potential consequences of climate change on crop production can be studied using mechanistic crop simulation models. While a broad variety of maize simulation models exist, it is not known whether different models diverge on grain yield responses to changes in climatic factors, or whether they agree in their general trends related to phenology, growth, and yield. With the goal of analyzing the sensitivity of simulated yields to changes in temperature and atmospheric carbon dioxide concentrations [CO2], we present the largest maize crop model intercomparison to date, including 23 different models. These models were evaluated for four locations representing a wide range of maize production conditions in the world: Lusignan (France), Ames (USA), Rio Verde (Brazil) and Morogoro (Tanzania). While individual models differed considerably in absolute yield simulation at the four sites, an ensemble of a minimum number of models was able to simulate absolute yields accurately at the four sites even with low data for calibration, thus suggesting that using an ensemble of models has merit. Temperature increase had strong negative influence on modeled yield response of roughly -0.5 Mg ha(sup 1) per degC. Doubling [CO2] from 360 to 720 lmol mol 1 increased grain yield by 7.5% on average across models and the sites. That would therefore make temperature the main factor altering maize yields at the end of this century. Furthermore, there was a large uncertainty in the yield response to [CO2] among models. Model responses to temperature and [CO2] did not differ whether models were simulated with low calibration information or, simulated with high level of calibration information.

  9. How do various maize crop models vary in their responses to climate change factors?

    PubMed

    Bassu, Simona; Brisson, Nadine; Durand, Jean-Louis; Boote, Kenneth; Lizaso, Jon; Jones, James W; Rosenzweig, Cynthia; Ruane, Alex C; Adam, Myriam; Baron, Christian; Basso, Bruno; Biernath, Christian; Boogaard, Hendrik; Conijn, Sjaak; Corbeels, Marc; Deryng, Delphine; De Sanctis, Giacomo; Gayler, Sebastian; Grassini, Patricio; Hatfield, Jerry; Hoek, Steven; Izaurralde, Cesar; Jongschaap, Raymond; Kemanian, Armen R; Kersebaum, K Christian; Kim, Soo-Hyung; Kumar, Naresh S; Makowski, David; Müller, Christoph; Nendel, Claas; Priesack, Eckart; Pravia, Maria Virginia; Sau, Federico; Shcherbak, Iurii; Tao, Fulu; Teixeira, Edmar; Timlin, Dennis; Waha, Katharina

    2014-07-01

    Potential consequences of climate change on crop production can be studied using mechanistic crop simulation models. While a broad variety of maize simulation models exist, it is not known whether different models diverge on grain yield responses to changes in climatic factors, or whether they agree in their general trends related to phenology, growth, and yield. With the goal of analyzing the sensitivity of simulated yields to changes in temperature and atmospheric carbon dioxide concentrations [CO2 ], we present the largest maize crop model intercomparison to date, including 23 different models. These models were evaluated for four locations representing a wide range of maize production conditions in the world: Lusignan (France), Ames (USA), Rio Verde (Brazil) and Morogoro (Tanzania). While individual models differed considerably in absolute yield simulation at the four sites, an ensemble of a minimum number of models was able to simulate absolute yields accurately at the four sites even with low data for calibration, thus suggesting that using an ensemble of models has merit. Temperature increase had strong negative influence on modeled yield response of roughly -0.5 Mg ha(-1) per °C. Doubling [CO2 ] from 360 to 720 μmol mol(-1) increased grain yield by 7.5% on average across models and the sites. That would therefore make temperature the main factor altering maize yields at the end of this century. Furthermore, there was a large uncertainty in the yield response to [CO2 ] among models. Model responses to temperature and [CO2 ] did not differ whether models were simulated with low calibration information or, simulated with high level of calibration information. © 2014 John Wiley & Sons Ltd.

  10. Evaluation of 4 Commercial Viewing Devices for Radiographic Perceptibility and Working Length Determination.

    PubMed

    Lally, Trent; Geist, James R; Yu, Qingzhao; Himel, Van T; Sabey, Kent

    2015-07-01

    This study compared images displayed on 1 desktop monitor, 1 laptop monitor, and 2 tablets for the detection of contrast and working length interpretation, with a null hypothesis of no differences between the devices. Three aluminum blocks, with milled circles of varying depth, were radiographed at various exposure levels to create 45 images of varying radiographic density. Six observers viewed the images on 4 devices: Lenovo M92z desktop (Lenovo, Beijing, China), Lenovo Z580 laptop (Lenovo), iPad 3 (Apple, Cupertino, CA), and iPad mini (Apple). Observers recorded the number of circles detected for each image, and a perceptibility curve was used to compare the devices. Additionally, 42 extracted teeth were imaged with working length files affixed at various levels (short, flush, and long) relative to the anatomic apex. Observers measured the distance from file tip to tooth apex on each device. The absolute mean measurement error was calculated for each image. Analysis of variance tests compared the devices. Observers repeated their sessions 1 month later to evaluate intraobserver reliability as measured with weighted kappa tests. Interclass correlation coefficients compared interobserver reliability. There was no significant difference in perceptibility detection between the Lenovo M92z desktop, iPad 3, and iPad mini. However, on average, all 3 were significantly better than the Lenovo Z580 laptop (P values ≤.015). No significant difference in the mean absolute error was noted for working length measurements among the 4 viewing devices (P = .3509). Although all 4 viewing devices seemed comparable with regard to working length evaluation, the laptop computer screen had lower overall ability to perceive contrast differences. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. A Dime a Day: The Possibilities and Limits of Private Schooling in Pakistan

    ERIC Educational Resources Information Center

    Andrabi, Tahir; Das, Jishnu; Khwaja, Asim Ijaz

    2008-01-01

    The authors of this article state that Pakistan is severely offtrack in its progress toward the Millennium Development Goals relating to education for all. Its educational performance is poor, both in absolute terms and relative to the average income of the country. Pakistan has received global attention because of the widespread perception that…

  12. It's the Local Economy, Stupid! Geographic Wealth Dispersion and Conflict Outbreak Location

    ERIC Educational Resources Information Center

    Buhaug, Halvard; Gleditsch, Kristian Skrede; Holtermann, Helge; Ostby, Gudrun; Tollefsen, Andreas Foro

    2011-01-01

    Income varies considerably within countries and the locations where conflicts emerge are rarely typical or representative for states at large. Yet, most research on conflict has only examined national income averages and neglected spatial variation. The authors argue that civil conflicts are more likely to erupt in areas with low absolute income,…

  13. A FORMULA FOR HUMAN PAROTID FLUID COLLECTED WITHOUT EXOGENEOUS STIMULATION.

    DTIC Science & Technology

    Parotid fluid was collected from 4,589 systemically healthy males between 17 and 22 years of age. Collection devices were placed with an absolute...secretion of the parotid gland. For all 4,589 subjects from the 8 experiments the mean rate of flow was 0.040 ml./minute with an average standard deviation of

  14. Evaluation of a Commercial Air Filter for Removal of Virus from the Air

    PubMed Central

    Roelants, P.; Boon, B.; Lhoest, W.

    1968-01-01

    The effectiveness of a commercial absolute air filter for removal of viruses from air was tested with an actinophage, under the usual conditions of a laminar airflow clean room. A new method of dry phage dispersion is described. The filter showed an average reduction of 99.996% of airborne actinophage. PMID:5684200

  15. Damage to southern Michigan conifers during the winter of 1976-77

    Treesearch

    Jonathan W. Wright; Donald DeHayes; Walter A. Lemmien

    1977-01-01

    In southern Michigan, the winter of 1976-1977 was marked by unseasonably cold weather in early December, prolonged cold weather in December and January, severe drought at the onset of cold weather, and by higher than average absolute minimum temperatures. Damage, presumably from the early December cold weather, was severe to southern seedlots of ponderosa pine,...

  16. Development and application of absolute quantitative detection by duplex chamber-based digital PCR of genetically modified maize events without pretreatment steps.

    PubMed

    Zhu, Pengyu; Fu, Wei; Wang, Chenguang; Du, Zhixin; Huang, Kunlun; Zhu, Shuifang; Xu, Wentao

    2016-04-15

    The possibility of the absolute quantitation of GMO events by digital PCR was recently reported. However, most absolute quantitation methods based on the digital PCR required pretreatment steps. Meanwhile, singleplex detection could not meet the demand of the absolute quantitation of GMO events that is based on the ratio of foreign fragments and reference genes. Thus, to promote the absolute quantitative detection of different GMO events by digital PCR, we developed a quantitative detection method based on duplex digital PCR without pretreatment. Moreover, we tested 7 GMO events in our study to evaluate the fitness of our method. The optimized combination of foreign and reference primers, limit of quantitation (LOQ), limit of detection (LOD) and specificity were validated. The results showed that the LOQ of our method for different GMO events was 0.5%, while the LOD is 0.1%. Additionally, we found that duplex digital PCR could achieve the detection results with lower RSD compared with singleplex digital PCR. In summary, the duplex digital PCR detection system is a simple and stable way to achieve the absolute quantitation of different GMO events. Moreover, the LOQ and LOD indicated that this method is suitable for the daily detection and quantitation of GMO events. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Conditioning procedure and color discrimination in the honeybee Apis mellifera

    NASA Astrophysics Data System (ADS)

    Giurfa, Martin

    We studied the influence of the conditioning procedure on color discrimination by free-flying honeybees. We asked whether absolute and differential conditioning result in different discrimination capabilities for the same pairs of colored targets. In absolute conditioning, bees were rewarded on a single color; in differential conditioning, bees were rewarded on the same color but an alternative, non-rewarding, similar color was also visible. In both conditioning procedures, bees learned their respective task and could also discriminate the training stimulus from a novel stimulus that was perceptually different from the trained one. Discrimination between perceptually closer stimuli was possible after differential conditioning but not after absolute conditioning. Differences in attention inculcated by these training procedures may underlie the different discrimination performances of the bees.

  18. Developmental Changes in the Effect of Active Left and Right Head Rotation on Random Number Generation

    PubMed Central

    Sosson, Charlotte; Georges, Carrie; Guillaume, Mathieu; Schuller, Anne-Marie; Schiltz, Christine

    2018-01-01

    Numbers are thought to be spatially organized along a left-to-right horizontal axis with small/large numbers on its left/right respectively. Behavioral evidence for this mental number line (MNL) comes from studies showing that the reallocation of spatial attention by active left/right head rotation facilitated the generation of small/large numbers respectively. While spatial biases in random number generation (RNG) during active movement are well established in adults, comparable evidence in children is lacking and it remains unclear whether and how children’s access to the MNL is affected by active head rotation. To get a better understanding of the development of embodied number processing, we investigated the effect of active head rotation on the mean of generated numbers as well as the mean difference between each number and its immediately preceding response (the first order difference; FOD) not only in adults (n = 24), but also in 7- to 11-year-old elementary school children (n = 70). Since the sign and absolute value of FODs carry distinct information regarding spatial attention shifts along the MNL, namely their direction (left/right) and size (narrow/wide) respectively, we additionally assessed the influence of rotation on the total of negative and positive FODs regardless of their numerical values as well as on their absolute values. In line with previous studies, adults produced on average smaller numbers and generated smaller mean FODs during left than right rotation. More concretely, they produced more negative/positive FODs during left/right rotation respectively and the size of negative FODs was larger (in terms of absolute value) during left than right rotation. Importantly, as opposed to adults, no significant differences in RNG between left and right head rotations were observed in children. Potential explanations for such age-related changes in the effect of active head rotation on RNG are discussed. Altogether, the present study confirms that numerical processing is spatially grounded in adults and suggests that its embodied aspect undergoes significant developmental changes. PMID:29541048

  19. Absolutely nondestructive discrimination of Huoshan Dendrobium nobile species with miniature near-infrared (NIR) spectrometer engine.

    PubMed

    Hu, Tian; Yang, Hai-Long; Tang, Qing; Zhang, Hui; Nie, Lei; Li, Lian; Wang, Jin-Feng; Liu, Dong-Ming; Jiang, Wei; Wang, Fei; Zang, Heng-Chang

    2014-10-01

    As one very precious traditional Chinese medicine (TCM), Huoshan Dendrobium has not only high price, but also significant pharmaceutical efficacy. However, different species of Huoshan Dendrobium exhibit considerable difference in pharmaceutical efficacy, so rapid and absolutely non-destructive discrimination of Huoshan Dendrobium nobile according to different species is crucial to quality control and pharmaceutical effect. In this study, as one type of miniature near-infrared (NIR) spectrometer, MicroNIR 1700 was used for absolutely nondestructive determination of NIR spectra of 90 batches of Dendrobium from five species of differ- ent commodity grades. The samples were intact and not smashed. Soft independent modeling of class analogy (SIMCA) pattern recognition based on principal component analysis (PCA) was used to classify and recognize different species of Dendrobium samples. The results indicated that the SIMCA qualitative models established with pretreatment method of standard normal variate transformation (SNV) in the spectra range selected by Qs method had 100% recognition rates and 100% rejection rates. This study demonstrated that a rapid and absolutely non-destructive analytical technique based on MicroNIR 1700 spectrometer was developed for successful discrimination of five different species of Huoshan Dendrobium with acceptable accuracy.

  20. Area-under-the-curve monitoring of cyclosporine therapy: Performance of different assay methods and their target concentrations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grevel, J.; Napoli, K.L.; Gibbons, S.

    1990-01-01

    The measurement of areas under the concentration-time curve (AUC) was recently introduced as an alternative to trough level monitoring of cyclosporine therapy. The AUC is divided by the oral dosing interval to calculate an average concentration. All measurements are performed at clinical steady state. The initial evaluation of AUC monitoring showed advantages over trough level monitoring with concentrations of cyclosporine measured in serum by the polyclonal radioimmunoassay of Sandoz. This assay technique is no longer available and the following assays were performed in parallel during up to 173 AUC determinations in 51 consecutive renal transplant patients: polyclonal fluorescence polarization immunoassaymore » of Abbott in serum, specific and nonspecific monoclonal radioimmunoassays using {sup 3}H and {sup 125}I tracers in serum and whole blood, and high performance liquid chromatography in whole blood. Both trough levels and average concentrations at steady state measured by those different techniques were significantly correlated with the oral dose. The best correlation (r2 = 0.54) was shown by average concentrations measured in whole blood by the specific monoclonal radioimmunoassay of Sandoz ({sup 3}H tracer). This monitoring technique was also associated with the smallest absolute error between repeated observations in the same patient while the oral dose rate remained the same or was changed. Both allegedly specific monoclonal radioimmunoassays (with {sup 3}H and {sup 125}I tracer) measured significantly higher concentrations than the liquid chromatography.« less

  1. SU-D-201-04: Study On the Impact of Tumor Shape and Size On Drug Delivery to Pancreatic Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soltani, M; Bazmara, H; Sefidgar, M

    Purpose: Drug delivery to solid tumors can be expressed physically using transport phenomena such as convection and diffusion for the drug of interest within extracellular matrices. We aimed to carefully model these phenomena, and to investigate the effect of tumor shape and size on drug delivery to solid tumors in the pancreas. Methods: In this study, multiple tumor geometries as obtained from clinical PET/CT images were considered. An advanced numerical method was used to simultaneously solve fluid flow and solute transport equations. Data from n=45 pancreatic cancer patients with non-resectable locoregional disease were analyzed, and geometrical information from the tumorsmore » including size, shape, and aspect ratios were classified. To investigate effect of tumor shape, tumors with similar size but different shapes were selected and analyzed. Moreover, to investigate effect of tumor size, tumors with similar shapes but different sizes, ranging from 1 to 77 cm{sup 3}, were selected and analyzed. A hypothetical tumor similar to one of the analyzed tumors, but scaled to reduce its size below 0.2 cm{sup 3}, was also analyzed. Results: The results showed relatively similar average drug concentration profiles in tumors with different sizes. Generally, smaller tumors had higher absolute drug concentration. In the hypothetical tumor, with volume less than 0.2 cm{sup 3}, the average drug concentration was 20% higher in comparison to its counterparts. For the various real tumor geometries, however, the maximum difference between average drug concentrations was 10% for the smallest and largest tumors. Moreover, the results demonstrated that for pancreatic tumors the shape is not significant. The negligible difference of drug concentration in different tumor shapes was due to the minimum effect of convection in pancreatic tumors. Conclusion: In tumors with different sizes, smaller tumors have higher drug delivery; however, the impact of tumor shape in the case of pancreatic tumors is not significant.« less

  2. Redefinition of the crater-density and absolute-age boundaries for the chronostratigraphic system of Mars

    USGS Publications Warehouse

    Werner, S.C.; Tanaka, K.L.

    2011-01-01

    For the boundaries of each chronostratigraphic epoch on Mars, we present systematically derived crater-size frequencies based on crater counts of geologic referent surfaces and three proposed " standard" crater size-frequency production distributions as defined by (a) a simple -2 power law, (b) Neukum and Ivanov, (c) Hartmann. In turn, these crater count values are converted to model-absolute ages based on the inferred cratering rate histories. We present a new boundary definition for the Late Hesperian-Early Amazonian transition. Our fitting of crater size-frequency distributions to the chronostratigraphic record of Mars permits the assignment of cumulative counts of craters down to 100. m, 1. km, 2. km, 5. km, and 16. km diameters to martian epochs. Due to differences in the " standard" crater size-frequency production distributions, a generalized crater-density-based definition to the chronostratigraphic system cannot be provided. For the diameter range used for the boundary definitions, the resulting model absolute age fits vary within 1.5% for a given set of production function and chronology model ages. Crater distributions translated to absolute ages utilizing different curve descriptions can result in absolute age differences exceeding 10%. ?? 2011 Elsevier Inc.

  3. [Individual growth modeling of the penshell Atrina maura (Bivalvia: Pinnidae) using a multi model inference approach].

    PubMed

    Aragón-Noriega, Eugenio Alberto

    2013-09-01

    Growth models of marine animals, for fisheries and/or aquaculture purposes, are based on the popular von Bertalanffy model. This tool is mostly used because its parameters are used to evaluate other fisheries models, such as yield per recruit; nevertheless, there are other alternatives (such as Gompertz, Logistic, Schnute) not yet used by fishery scientists, that may result useful depending on the studied species. The penshell Atrina maura, has been studied for fisheries or aquaculture supplies, but its individual growth has not yet been studied before. The aim of this study was to model the absolute growth of the penshell A. maura using length-age data. For this, five models were assessed to obtain growth parameters: von Bertalanffy, Gompertz, Logistic, Schnute case 1 and Schnute and Richards. The criterion used to select the best models was the Akaike information criterion, as well as the residual squared sum and R2 adjusted. To get the average asymptotic length, the multi model inference approach was used. According to Akaike information criteria, the Gompertz model better described the absolute growth of A. maura. Following the multi model inference approach the average asymptotic shell length was 218.9 mm (IC 212.3-225.5) of shell length. I concluded that the use of the multi model approach and the Akaike information criteria represented the most robust method for growth parameter estimation of A. maura and the von Bertalanffy growth model should not be selected a priori as the true model to obtain the absolute growth in bivalve mollusks like in the studied species in this paper.

  4. Teaching Point-of-Care Lung Ultrasound to Novice Pediatric Learners: Web-Based E-Learning Versus Traditional Classroom Didactic.

    PubMed

    Soon, Aun Woon; Toney, Amanda Greene; Stidham, Timothy; Kendall, John; Roosevelt, Genie

    2018-04-24

    To assess whether Web-based teaching is at least as effective as traditional classroom didactic in improving the proficiency of pediatric novice learners in the image acquisition and interpretation of pneumothorax and pleural effusion using point-of-care ultrasound (POCUS). We conducted a randomized controlled noninferiority study comparing the effectiveness of Web-based teaching to traditional classroom didactic. The participants were randomized to either group A (live classroom lecture) or group B (Web-based lecture) and completed a survey and knowledge test. They also received hands-on training and completed an objective structured clinical examination. The participants were invited to return 2 months later to test for retention of knowledge and skills. There were no significant differences in the mean written test scores between the classroom group and Web group for the precourse test (absolute difference, -2.5; 95% confidence interval [CI], -12 to 6.9), postcourse test (absolute difference, 2.0; 95% CI, -1.4, 5.3), and postcourse 2-month retention test (absolute difference, -0.8; 95% CI, -9.6 to 8.1). Similarly, no significant differences were noted in the mean objective structured clinical examination scores for both intervention groups in postcourse (absolute difference, 1.9; 95% CI, -4.7 to 8.5) and 2-month retention (absolute difference, -0.6; 95% CI, -10.7 to 9.5). Web-based teaching is at least as effective as traditional classroom didactic in improving the proficiency of novice learners in POCUS. The usage of Web-based tutorials allows a more efficient use of time and a wider dissemination of knowledge.

  5. In-vivo studies of reflectance pulse oximeter sensor

    NASA Astrophysics Data System (ADS)

    Ling, Jian; Takatani, Setsuo; Noon, George P.; Nose, Yukihiko

    1993-08-01

    Reflectance oximetry can offer an advantage of being applicable to any portion of the body. However, the major problem of reflectance oximetry is low pulsatile signal level which prevents prolonged clinical application during extreme situations, such as hypothermia and vasoconstriction. In order to improve the pulsatile signal level of reflectance pulse oximeter and thus its accuracy, three different sensors, with the separation distances (SPD) between light emitting diode (LED) and photodiode being 3, 5, and 7 mm respectively, were studied on nine healthy volunteers. With the increase of the SPD, it was found that both the red (660 nm) and near-infrared (830 nm) pulsatile to average signal ratio (AC/DC) increased, and the standard deviations of (AC/DC)red/(AC/DC)infrared ratio decreased, in spite of the decrease of the absolute signal level. Further clinical studies of 3 mm and 7 mm SPD sensors on seven patients also showed that the (AC/DC)red/(AC/DC)infrared ratio measured by the 7 mm sensor were less disturbed than the 3 mm sensor during the surgery. A theoretical study based on the three-dimensional photon diffusion theory supports the experimental and clinical results. As a conclusion, the 7 mm sensor has the highest signal-to- noise ratio among three different sensors. A new 7 mm SPD reflectance sensor, with the increased number of LEDs around the photodiode, was designed to increase the AC/DC ratio, as well as to increase the absolute signal level.

  6. Low lymphatic vessel density associates with chronic rhinosinusitis with nasal polyps.

    PubMed

    Luukkainen, A; Seppälä, M; Renkonen, J; Renkonen, R; Hagstrő M, J; Huhtala, H; Rautiainen, M; Myller, J; Paavonen, T; Ranta, A; Torkkeli, T; Toppila-Salmi, S

    2017-06-01

    Chronic rhinosinusitis with and without nasal polyps (CRSwNP and CRSsNP) and antrochoanal polyps (ACP) are different upper airway inflammation phenotypes with different pathomechanisms. In order to understand the development of tissue edema, the present study aimed to evaluate lymphatic vessel density in CRSsNP, CRSwNP and ACP. 120 retrospective nasal and maxillary sinus specimens were stained immunohistochemically with a von Willebrand factor polyclonal antibody recognizing vascular and lymphatic endothelium, and with a podoplanin monoclonal antibody recognizing lymphatic endothelium. Vessels were studied by microscopy in a blinded fashion, and the vessel density and the relative density of lymphatic vessels were calculated. Patient characteristic factors and follow-up data of in average 9 years were collected from patient records. In the nasal cavity, the low absolute and relative density of vessels and of lymphatic vessels was associated with CRSwNP and ACP tissues compared to control inferior turbinate. This was observed also in the inflammatory hotspot area. In the maxillary sinus, lower absolute and relative density of lymphatic vessels associated with the CRSwNP phenotype. High lymphatic vessel density in polyp tissue associated with the need for revision CRS-surgery. As a conclusion, low density of lymphatic vessels distinguished patients with CRSwNP not only in the hotspot area of polyp tissue, but also in maxillary sinus mucosa. Yet, higher lymphatic vessel density seems to associate with polyp recurrence. Further studies are still needed to explore if formation of nasal polyps could be diminished by intranasal therapeutics affecting lymphangiogenesis.

  7. Comparison of elicitation potential of chloroatranol and atranol--2 allergens in oak moss absolute.

    PubMed

    Johansen, Jeanne D; Bernard, Guillaume; Giménez-Arnau, Elena; Lepoittevin, Jean-Pierre; Bruze, Magnus; Andersen, Klaus E

    2006-04-01

    Chloroatranol and atranol are degradation products of chloroatranorin and atranorin, respectively, and have recently been identified as important contact allergens in the natural fragrance extract, oak moss absolute. Oak moss absolute is widely used in perfumery and is the cause of many cases of fragrance allergic contact dermatitis. Chloroatranol elicits reactions at very low levels of exposure. In oak moss absolute, chloroatranol and atranol are present together and both may contribute to the allergenicity and eliciting capacity of the natural extract. In this study, 10 eczema patients with known sensitization to chloroatranol and oak moss absolute were tested simultaneously to a serial dilution of chloroatranol and atranol in ethanol, in equimolar concentrations (0.0034-1072 microM). Dose-response curves were estimated and analysed by logistic regression. The estimated difference in elicitation potency of chloroatranol relative to atranol based on testing with equimolar concentrations was 217% (95% confidence interval 116-409%). Both substances elicited reactions at very low levels of exposure. It is concluded that the differences in elicitation capacity between the 2 substances are counterbalanced by exposure being greater to atranol than to chloroatranol and that both substances contribute to the clinical problems seen in oak moss absolute-sensitized individuals.

  8. Luminosity determination in pp collisions at $$\\sqrt{s} = 7$$ TeV using the ATLAS detector at the LHC

    DOE PAGES

    Aad, G.; Abbott, B.; Abdallah, J.; ...

    2011-04-27

    Measurements of luminosity obtained using the ATLAS detector during early running of the Large Hadron Collider (LHC) at √s = 7 TeV are presented. The luminosity is independently determined using several detectors and multiple algorithms, each having different acceptances, systematic uncertainties and sensitivity to background. The ratios of the luminosities obtained from these methods are monitored as a function of time and of μ, the average number of inelastic interactions per bunch crossing. Residual time- and μ-dependence between the methods is less than 2% for 0 < μ < 2.5. Absolute luminosity calibrations, performed using beam separation scans, have amore » common systematic uncertainty of ±11%, dominated by the measurement of the LHC beam currents. After calibration, the luminosities obtained from the different methods differ by at most ±2%. The visible cross sections measured using the beam scans are compared to predictions obtained with the PYTHIA and PHOJET event generators and the ATLAS detector simulation.« less

  9. Calculations of Nuclear Astrophysics and Californium Fission Neutron Spectrum Averaged Cross Section Uncertainties Using ENDF/B-VII.1, JEFF-3.1.2, JENDL-4.0 and Low-fidelity Covariances

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pritychenko, B., E-mail: pritychenko@bnl.gov

    Nuclear astrophysics and californium fission neutron spectrum averaged cross sections and their uncertainties for ENDF materials have been calculated. Absolute values were deduced with Maxwellian and Mannhart spectra, while uncertainties are based on ENDF/B-VII.1, JEFF-3.1.2, JENDL-4.0 and Low-Fidelity covariances. These quantities are compared with available data, independent benchmarks, EXFOR library, and analyzed for a wide range of cases. Recommendations for neutron cross section covariances are given and implications are discussed.

  10. Determination of the absolute binding free energies of HIV-1 protease inhibitors using non-equilibrium molecular dynamics simulations

    NASA Astrophysics Data System (ADS)

    Ngo, Son Tung; Nguyen, Minh Tung; Nguyen, Minh Tho

    2017-05-01

    The absolute binding free energy of an inhibitor to HIV-1 Protease (PR) was determined throughout evaluation of the non-bonded interaction energy difference between the two bound and unbound states of the inhibitor and surrounding molecules by the fast pulling of ligand (FPL) process using non-equilibrium molecular dynamics (NEMD) simulations. The calculated free energy difference terms help clarifying the nature of the binding. Theoretical binding affinities are in good correlation with experimental data, with R = 0.89. The paradigm used is able to rank two inhibitors having the maximum difference of ∼1.5 kcal/mol in absolute binding free energies.

  11. Urban-rural inequality regarding drug prescriptions in primary care facilities - a pre-post comparison of the National Essential Medicines Scheme of China.

    PubMed

    Yao, Qiang; Liu, Chaojie; Ferrier, J Adamm; Liu, Zhiyong; Sun, Ju

    2015-07-30

    To assess the impact of the National Essential Medicines Scheme (NEMS) with respect to urban-rural inequalities regarding drug prescriptions in primary care facilities. A stratified two-stage random sampling strategy was used to sample 23,040 prescriptions from 192 primary care facilities from 2009 to 2010. Difference-in-Difference (DID) analyses were performed to test the association between NEMS and urban-rural gaps in prescription patterns. Between-Group Variance and Theil Index were calculated to measure urban-rural absolute and relative disparities in drug prescriptions. The use of the Essential Medicines List (EML) achieved a compliance rate of up to 90% in both urban and rural facilities. An overall reduction of average prescription cost improved economic access to drugs for patients in both areas. However, we observed an increased urban-rural disparity in average expenditure per prescription. The rate of antibiotics and glucocorticoids prescription remained high, despite a reduced disparity between urban and rural facilities. The average incidence of antibiotic prescription increased slightly in urban facilities (62 to 63%) and reduced in rural facilities (67% to 66%). The urban-rural disparity in the use of parenteral administration (injections and infusions) increased, albeit at a high level in both areas (44%-52%). NEMS interventions are effective in reducing the overall average prescription costs. Despite the increased use of the EML, indicator performances with respect to rational drug prescribing and use remain poor and exceed the WHO/INRUD recommended cutoff values and worldwide benchmarks. There is an increased gap between urban and rural areas in the use of parenteral administration and expenditure per prescription.

  12. Digital optical imaging of green fluorescent proteins for tracking vascular gene expression: feasibility study in rabbit and human cell models.

    PubMed

    Yang, X; Liu, H; Li, D; Zhou, X; Jung, W C; Deans, A E; Cui, Y; Cheng, L

    2001-04-01

    To investigate the feasibility of using a sensitive digital optical imaging technique to detect green fluorescent protein (GFP) expressed in rabbit vasculature and human arterial smooth muscle cells. A GFP plasmid was transfected into human arterial smooth muscle cells to obtain a GFP-smooth muscle cell solution. This solution was imaged in cell phantoms by using a prototype digital optical imaging system. For in vivo validation, a GFP-lentivirus vector was transfected during surgery into the carotid arteries of two rabbits, and GFP-targeted vessels were harvested for digital optical imaging ex vivo. Optical imaging of cell phantoms resulted in a spatial resolution of 25 microm/pixel. Fluorescent signals were detected as diffusely distributed bright spots. At ex vivo optical imaging of arterial tissues, the average fluorescent signal was significantly higher (P <.05) in GFP-targeted tissues (mean +/- SD, 9,357.3 absolute units of density +/- 1,001.3) than in control tissues (5,633.7 absolute units of density +/- 985.2). Both fluorescence microscopic and immunohistochemical findings confirmed these differences between GFP-targeted and control vessels. The digital optical imaging system was sensitive to GFPs and may potentially provide an in vivo imaging tool to monitor and track vascular gene transfer and expression in experimental investigations.

  13. What weather variables are important in predicting heat-related mortality? A new application of statistical learning methods

    PubMed Central

    Zhang, Kai; Li, Yun; Schwartz, Joel D.; O'Neill, Marie S.

    2014-01-01

    Hot weather increases risk of mortality. Previous studies used different sets of weather variables to characterize heat stress, resulting in variation in heat-mortality- associations depending on the metric used. We employed a statistical learning method – random forests – to examine which of various weather variables had the greatest impact on heat-related mortality. We compiled a summertime daily weather and mortality counts dataset from four U.S. cities (Chicago, IL; Detroit, MI; Philadelphia, PA; and Phoenix, AZ) from 1998 to 2006. A variety of weather variables were ranked in predicting deviation from typical daily all-cause and cause-specific death counts. Ranks of weather variables varied with city and health outcome. Apparent temperature appeared to be the most important predictor of heat-related mortality for all-cause mortality. Absolute humidity was, on average, most frequently selected one of the top variables for all-cause mortality and seven cause-specific mortality categories. Our analysis affirms that apparent temperature is a reasonable variable for activating heat alerts and warnings, which are commonly based on predictions of total mortality in next few days. Additionally, absolute humidity should be included in future heat-health studies. Finally, random forests can be used to guide choice of weather variables in heat epidemiology studies. PMID:24834832

  14. EIT Imaging of admittivities with a D-bar method and spatial prior: experimental results for absolute and difference imaging.

    PubMed

    Hamilton, S J

    2017-05-22

    Electrical impedance tomography (EIT) is an emerging imaging modality that uses harmless electrical measurements taken on electrodes at a body's surface to recover information about the internal electrical conductivity and or permittivity. The image reconstruction task of EIT is a highly nonlinear inverse problem that is sensitive to noise and modeling errors making the image reconstruction task challenging. D-bar methods solve the nonlinear problem directly, bypassing the need for detailed and time-intensive forward models, to provide absolute (static) as well as time-difference EIT images. Coupling the D-bar methodology with the inclusion of high confidence a priori data results in a noise-robust regularized image reconstruction method. In this work, the a priori D-bar method for complex admittivities is demonstrated effective on experimental tank data for absolute imaging for the first time. Additionally, the method is adjusted for, and tested on, time-difference imaging scenarios. The ability of the method to be used for conductivity, permittivity, absolute as well as time-difference imaging provides the user with great flexibility without a high computational cost.

  15. Relatively Different? How Do Gender Differences in Well-Being Depend on Paid and Unpaid Work in Europe?

    ERIC Educational Resources Information Center

    Boye, Katarina

    2009-01-01

    Absolute as well as relative hours of paid and unpaid work may influence well-being. This study investigates whether absolute hours spent on paid work and housework account for the lower well-being among women as compared to men in Europe, and whether the associations between well-being and hours of paid work and housework differ by gender…

  16. Time series forecasting of future claims amount of SOCSO's employment injury scheme (EIS)

    NASA Astrophysics Data System (ADS)

    Zulkifli, Faiz; Ismail, Isma Liana; Chek, Mohd Zaki Awang; Jamal, Nur Faezah; Ridzwan, Ahmad Nur Azam Ahmad; Jelas, Imran Md; Noor, Syamsul Ikram Mohd; Ahmad, Abu Bakar

    2012-09-01

    The Employment Injury Scheme (EIS) provides protection to employees who are injured due to accidents whilst working, commuting from home to the work place or during employee takes a break during an authorized recess time or while travelling that is related with his work. The main purpose of this study is to forecast value on claims amount of EIS for the year 2011 until 2015 by using appropriate models. These models were tested on the actual EIS data from year 1972 until year 2010. Three different forecasting models are chosen for comparisons. These are the Naïve with Trend Model, Average Percent Change Model and Double Exponential Smoothing Model. The best model is selected based on the smallest value of error measures using the Mean Squared Error (MSE) and Mean Absolute Percentage Error (MAPE). From the result, the best model that best fit the forecast for the EIS is the Average Percent Change Model. Furthermore, the result also shows the claims amount of EIS for the year 2011 to year 2015 continue to trend upwards from year 2010.

  17. Averaging peak-to-peak voltage detector for absolute mass determination of single particles with quadrupole ion traps

    NASA Astrophysics Data System (ADS)

    Peng, Wen-Ping; Lee, Yuan T.; Ting, Joseph W.; Chang, Huan-Cheng

    2005-02-01

    A sine wave that controls a quadrupole ion trap is generated from a low voltage source, boosted to high voltage through a transformer. Since not even the best transformers can keep a flat amplitude response with respect to frequency, knowing the accurate peak-to-peak value of the sine wave is paramount when the frequency is varied. We have developed an averaging peak-to-peak voltage detector for such measurements and demonstrated that the device is an essential tool to make possible high-precision mass determination of single charged microparticles with masses greater than 1×1011u. Tests of the detector with sine waves from a FLUKE 5720A standard source in the neighborhood of 1400Vpp and frequencies ranging from 100to700Hz showed a measurement accuracy better than 10ppm. The detector settled within 5s after each reset to 5 digits of DVM rock-steady reading, and the calibration against the same source after 3weeks of continuous use of the circuit produced a mere overall 1ppm difference.

  18. Effects of different fresh gas flows with or without a heat and moisture exchanger on inhaled gas humidity in adults undergoing general anaesthesia: A systematic review and meta-analysis of randomised controlled trials.

    PubMed

    Braz, José R C; Braz, Mariana G; Hayashi, Yoko; Martins, Regina H G; Betini, Marluci; Braz, Leandro G; El Dib, Regina

    2017-08-01

    The minimum inhaled gas absolute humidity level is 20 mgH2O l for short-duration use in general anaesthesia and 30 mgH2O l for long-duration use in intensive care to avoid respiratory tract dehydration. The aim is to compare the effects of different fresh gas flows (FGFs) through a circle rebreathing system with or without a heat and moisture exchanger (HME) on inhaled gas absolute humidity in adults undergoing general anaesthesia. Systematic review and meta-analyses of randomised controlled trials. We defined FGF (l min) as minimal (0.25 to 0.5), low (0.6 to 1.0) or high (≥2). We extracted the inhaled gas absolute humidity data at 60 and 120 min after connection of the patient to the breathing circuit. The effect size is expressed as the mean differences and corresponding 95% confidence intervals (CI). PubMed, EMBASE, SciELO, LILACS and CENTRAL until January 2017. We included 10 studies. The inhaled gas absolute humidity was higher with minimal flow compared with low flow at 120 min [mean differences 2.51 (95%CI: 0.32 to 4.70); P = 0.02] but not at 60 min [mean differences 2.95 (95%CI: -0.95 to 6.84); P = 0.14], and higher with low flow compared with high flow at 120 min [mean differences 7.19 (95%CI: 4.53 to 9.86); P < 0.001]. An inhaled gas absolute humidity minimum of 20 mgH2O l was attained with minimal flow at all times but not with low or high flows. An HME increased the inhaled gas absolute humidity: with minimal flow at 120 min [mean differences 8.49 (95%CI: 1.15 to 15.84); P = 0.02]; with low flow at 60 min [mean differences 9.87 (95%CI: 3.18 to 16.57); P = 0.04] and 120 min [mean differences 7.19 (95%CI: 3.29 to 11.10); P = 0.003]; and with high flow of 2 l min at 60 min [mean differences 6.46 (95%CI: 4.05 to 8.86); P < 0.001] and of 3 l min at 120 min [mean differences 12.18 (95%CI: 6.89 to 17.47); P < 0.001]. The inhaled gas absolute humidity data attained or were near 30 mgH2O l when an HME was used at all FGFs and times. All intubated patients should receive a HME with low or high flows. With minimal flow, a HME adds cost and is not needed to achieve an appropriate inhaled gas absolute humidity.

  19. NT-proBNP and Heart Failure Risk Among Individuals With and Without Obesity: The ARIC Study

    PubMed Central

    Ndumele, Chiadi E.; Matsushita, Kunihiro; Sang, Yingying; Lazo, Mariana; Agarwal, Sunil K.; Nambi, Vijay; Deswal, Anita; Blumenthal, Roger S.; Ballantyne, Christie M.; Coresh, Josef; Selvin, Elizabeth

    2016-01-01

    Background Obesity is a risk factor for heart failure (HF), but is associated with lower N-terminal of pro-Brain Natriuretic Peptide (NT-proBNP) levels. It is unclear whether the prognostic value and implications of NT-proBNP levels for HF risk differ across body mass index (BMI) categories. Methods and Results We followed 12,230 ARIC participants free of prior HF at baseline (visit 2, 1990–1992) with BMI ≥18.5 kg/m2. We quantified and compared the relative and absolute risk associations of NT-proBNP with incident HF across BMI categories. There were 1,861 HF events during a median 20.6 years of follow-up. Despite increased HF risk in obesity, a weak inverse association was seen between baseline BMI and NT-proBNP levels (r = −0.10). Nevertheless, higher baseline NT-proBNP was associated with increased HF risk in all BMI categories. NT-proBNP improved HF risk prediction overall and even among those with severe obesity (BMI ≥35 kg/m2; improvement in c-statistic +0.032 [95% CI 0.011–0.053]). However, given higher HF rates among those with obesity, at each NT-proBNP level, higher BMI was associated with greater absolute HF risk. Indeed, among those with NT-proBNP 100 to < 200 pg/ml, the average 10-year HF risk was <5% among normal weight individuals but >10% if severely obese. Conclusions Despite its inverse relationship with BMI, NT-proBNP provides significant prognostic information regarding the risk of developing HF even among individuals with obesity. Given the higher baseline HF risk among persons with obesity, even slight elevations in NT-proBNP may have implications for increased absolute HF risk in this population. PMID:26746175

  20. Can mean platelet volume and neutrophil-to-lymphocyte ratio be biomarkers of acute exacerbation of bronchiectasis in children?

    PubMed Central

    Erdem, Semiha Bahceci; Karaman, Sait; Yazici, Selcuk; Can, Demet

    2017-01-01

    Introduction Bronchiectasis (BE) is a parenchymal lung disease evolving as a result of recurrent lung infections and chronic inflammation. Although it has been shown in adult studies that mean platelet volume (MPV) and neutrophil-to-lymphocyte ratio (NLR) can be used as biomarkers of airway inflammation, knowledge is limited in the paediatric age group. The aim of our study is to investigate the potential of MPV and NLR as biomarkers that may indicate acute exacerbations of non-cystic fibrosis BE in children. Material and methods Children with non-cystic fibrosis BE (n = 50), who were followed in the division of Paediatric Pulmonology of our hospital between June 2010 and July 2015, were involved in the present retrospective cross-sectional study. Haemogram values during acute exacerbations and non-exacerbation periods, and a control group were compared. Results In children with bronchiectasis, the average leukocyte count (p < 0.001), platelet count (p = 0.018), absolute neutrophil count (p < 0.001), and NLR (p < 0.001) were higher, as expected, when compared with the control group. NLR values, in the period of acute exacerbation were significantly higher than the values of both the non-exacerbation periods (p = 0.02) and the control group (p < 0.001). In contrast, MPV values in the period of acute exacerbation did not exhibit a significant difference from those of non-exacerbation periods (p = 0.530) and the control group (p = 0.103). Conclusions It was concluded that leukocyte count, platelet count, absolute neutrophil count, and NLR can be used to show chronic inflammation in BE, but only NLR and absolute neutrophil count can be used as biomarkers to show acute exacerbations. PMID:29472813

  1. Results of Absolute Cavity Pyrgeometer and Infrared Integrating Sphere Comparisons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reda, Ibrahim M; Sengupta, Manajit; Dooraghi, Michael R

    Accurate and traceable atmospheric longwave irradiance measurements are required for understanding radiative impacts on the Earth's energy budget. The standard to which pyrgeometers are traceable is the interim World Infrared Standard Group (WISG), maintained in the Physikalisch-Meteorologisches Observatorium Davos (PMOD). The WISG consists of four pyrgeometers that were calibrated using Rolf Philipona's Absolute Sky-scanning Radiometer [1]. The Atmospheric Radiation Measurement (ARM) facility has recently adopted the WISG to maintain the traceability of the calibrations of all Eppley precision infrared radiometer (PIR) pyrgeometers. Subsequently, Julian Grobner [2] developed the infrared interferometer spectrometer and radiometer (IRIS) radiometer, and Ibrahim Reda [3] developedmore » the absolute cavity pyrgeometer (ACP). The ACP and IRIS were developed to establish a world reference for calibrating pyrgeometers with traceability to the International System of Units (SI). The two radiometers are unwindowed with negligible spectral dependence, and they are traceable to SI units through the temperature scale (ITS-90). The two instruments were compared directly to the WISG three times at PMOD and twice at the Southern Great Plains (SGP) facility to WISG-traceable pyrgeometers. The ACP and IRIS agreed within +/- 1 W/m2 to +/- 3 W/m2 in all comparisons, whereas the WISG references exhibit a 2-5 Wm2 low bias compared to the ACP/IRIS average, depending on the water vapor column, as noted in Grobner et al. [4]. Consequently, a case for changing the current WISG has been made by Grobner and Reda. However, during the five comparisons the column water vapor exceeded 8 mm. Therefore, it is recommended that more ACP and IRIS comparisons should be held under different environmental conditions and water vapor column content to better establish the traceability of these instruments to SI with established uncertainty.« less

  2. A Mathematical Motivation for Complex-Valued Convolutional Networks.

    PubMed

    Tygert, Mark; Bruna, Joan; Chintala, Soumith; LeCun, Yann; Piantino, Serkan; Szlam, Arthur

    2016-05-01

    A complex-valued convolutional network (convnet) implements the repeated application of the following composition of three operations, recursively applying the composition to an input vector of nonnegative real numbers: (1) convolution with complex-valued vectors, followed by (2) taking the absolute value of every entry of the resulting vectors, followed by (3) local averaging. For processing real-valued random vectors, complex-valued convnets can be viewed as data-driven multiscale windowed power spectra, data-driven multiscale windowed absolute spectra, data-driven multiwavelet absolute values, or (in their most general configuration) data-driven nonlinear multiwavelet packets. Indeed, complex-valued convnets can calculate multiscale windowed spectra when the convnet filters are windowed complex-valued exponentials. Standard real-valued convnets, using rectified linear units (ReLUs), sigmoidal (e.g., logistic or tanh) nonlinearities, or max pooling, for example, do not obviously exhibit the same exact correspondence with data-driven wavelets (whereas for complex-valued convnets, the correspondence is much more than just a vague analogy). Courtesy of the exact correspondence, the remarkably rich and rigorous body of mathematical analysis for wavelets applies directly to (complex-valued) convnets.

  3. Measurement of the Am 242 m neutron-induced reaction cross sections

    DOE PAGES

    Buckner, M. Q.; Wu, C. Y.; Henderson, R. A.; ...

    2017-02-17

    The neutron-induced reaction cross sections of 242mAm were measured at the Los Alamos Neutron Science Center using the Detector for Advanced Neutron-Capture Experiments array along with a compact parallel-plate avalanche counter for fission-fragment detection. A new neutron-capture cross section was determined, and the absolute scale was set according to a concurrent measurement of the well-known 242mAm(n,f) cross section. The (n,γ) cross section was measured from thermal energy to an incident energy of 1 eV at which point the data quality was limited by the reaction yield in the laboratory. Our new 242mAm fission cross section was normalized to ENDF/B-VII.1 tomore » set the absolute scale, and it agreed well with the (n,f) cross section from thermal energy to 1 keV. Lastly, the average absolute capture-to-fission ratio was determined from thermal energy to E n = 0.1 eV, and it was found to be 26(4)% as opposed to the ratio of 19% from the ENDF/B-VII.1 evaluation.« less

  4. Title I Elementary Teachers' Perceptions of Climate in Low/High Performing Schools

    ERIC Educational Resources Information Center

    Treadwell, Linda

    2016-01-01

    In this study, the researcher obtained three years of school-level state testing data from 1,467 Title I elementary schools in the state of Tennessee and analyzed the averages in context of teachers' responses on a state-wide TELL survey. The researcher wanted to see if teachers who taught in low-performing schools perceived the absolute and…

  5. Non-cooperative Brownian donkeys: A solvable 1D model

    NASA Astrophysics Data System (ADS)

    Jiménez de Cisneros, B.; Reimann, P.; Parrondo, J. M. R.

    2003-12-01

    A paradigmatic 1D model for Brownian motion in a spatially symmetric, periodic system is tackled analytically. Upon application of an external static force F the system's response is an average current which is positive for F < 0 and negative for F > 0 (absolute negative mobility). Under suitable conditions, the system approaches 100% efficiency when working against the external force F.

  6. Thermodynamic characterization of tandem mismatches found in naturally occurring RNA

    PubMed Central

    Christiansen, Martha E.; Znosko, Brent M.

    2009-01-01

    Although all sequence symmetric tandem mismatches and some sequence asymmetric tandem mismatches have been thermodynamically characterized and a model has been proposed to predict the stability of previously unmeasured sequence asymmetric tandem mismatches [Christiansen,M.E. and Znosko,B.M. (2008) Biochemistry, 47, 4329–4336], experimental thermodynamic data for frequently occurring tandem mismatches is lacking. Since experimental data is preferred over a predictive model, the thermodynamic parameters for 25 frequently occurring tandem mismatches were determined. These new experimental values, on average, are 1.0 kcal/mol different from the values predicted for these mismatches using the previous model. The data for the sequence asymmetric tandem mismatches reported here were then combined with the data for 72 sequence asymmetric tandem mismatches that were published previously, and the parameters used to predict the thermodynamics of previously unmeasured sequence asymmetric tandem mismatches were updated. The average absolute difference between the measured values and the values predicted using these updated parameters is 0.5 kcal/mol. This updated model improves the prediction for tandem mismatches that were predicted rather poorly by the previous model. This new experimental data and updated predictive model allow for more accurate calculations of the free energy of RNA duplexes containing tandem mismatches, and, furthermore, should allow for improved prediction of secondary structure from sequence. PMID:19509311

  7. On the Piezoelectric Detection of Guided Ultrasonic Waves

    PubMed Central

    2017-01-01

    In order to quantify the wave motion of guided ultrasonic waves, the characteristics of piezoelectric detectors, or ultrasonic transducers and acoustic emission sensors, have been evaluated systematically. Such guided waves are widely used in structural health monitoring and nondestructive evaluation, but methods of calibrating piezoelectric detectors have been inadequate. This study relied on laser interferometry for the base displacement measurement of bar waves, from which eight different guided wave test set-ups are developed with known wave motion using piezoelectric transmitters. Both plates and bars of 12.7 and 6.4 mm thickness were used as wave propagation media. The upper frequency limit was 2 MHz. Output of guided wave detectors were obtained on the test set-ups and their receiving sensitivities were characterized and averaged. While each sensitivity spectrum was noisy for a detector, the averaged spectrum showed a good convergence to a unique receiving sensitivity. Twelve detectors were evaluated and their sensitivity spectra determined in absolute units. Generally, these showed rapidly dropping sensitivity with increasing frequency due to waveform cancellation on their sensing areas. This effect contributed to vastly different sensitivities to guided wave and to normally incident wave for each one of the 12 detectors tested. Various other effects are discussed and recommendations on methods of implementing the approach developed are provided. PMID:29156579

  8. Determination of Residual Stress Distributions in Polycrystalline Alumina using Fluorescence Microscopy

    PubMed Central

    Michaels, Chris A.; Cook, Robert F.

    2016-01-01

    Maps of residual stress distributions arising from anisotropic thermal expansion effects in a polycrystalline alumina are generated using fluorescence microscopy. The shifts of both the R1 and R2 ruby fluorescence lines of Cr in alumina are used to create maps with sub-µm resolution of either the local mean and shear stresses or local crystallographic a- and c-stresses in the material, with approximately ± 1 MPa stress resolution. The use of single crystal control materials and explicit correction for temperature and composition effects on line shifts enabled determination of the absolute values and distributions of values of stresses. Temperature correction is shown to be critical in absolute stress determination. Experimental determinations of average stress parameters in the mapped structure are consistent with assumed equilibrium conditions and with integrated large-area measurements. Average crystallographic stresses of order hundreds of MPa are determined with characteristic distribution widths of tens of MPa. The stress distributions reflect contributions from individual clusters of stress in the structure; the cluster size is somewhat larger than the grain size. An example application of the use of stress maps is shown in the calculation of stress-intensity factors for fracture in the residual stress field. PMID:27563163

  9. [Tracing Sources of Sulfate Aerosol in Nanjing Northern Suburb Using Sulfur and Oxygen Isotopes].

    PubMed

    Wei, Ying; Guo, Zhao-bing; Ge, Xin; Zhu, Sheng-nan; Jiang, Wen-juan; Shi, Lei; Chen, Shu

    2015-04-01

    Abstract: To trace the sources of sulfate contributing to atmospheric aerosol, PM2.5 samples for isotopic analysis were collected in Nanjing northern suburb during January 2014. The sulfur and oxygen isotopic compositions of sulfate from these samples were determined by EA-IRMS. Source identification and apportionment were carried out using stable isotopic and chemical evidences, combined with absolute principal component analysis (APCA) method. The Δ34S values of aerosol sulfate ranged from 2.7 per thousand to 6.4 per thousand, with an average of 5.0 per thousand ± 0.9 per thousand, while the Δ18O values ranged from 10.6 per thousand to 16.1 per thousand, with an average of 12.5 per thousand ± 1.37 per thousand. In conjunction with air mass trajectories, the results suggested that aerosol sulfates were controlled by a dominance of local anthropogenic sulfate, followed by the contributions of long-distance transported sulfate. There was a minor effect of some other low-Δ34S valued sulfates, which might be expected from biogenic sources. Absolute principal component analysis results showed that the contributions of anthropogenic sulfate and long-distance transported sulfate were 46.74% and 31.54%, respectively.

  10. Modelling PET radionuclide production in tissue and external targets using Geant4

    NASA Astrophysics Data System (ADS)

    Amin, T.; Infantino, A.; Lindsay, C.; Barlow, R.; Hoehr, C.

    2017-07-01

    The Proton Therapy Facility in TRIUMF provides 74 MeV protons extracted from a 500 MeV H- cyclotron for ocular melanoma treatments. During treatment, positron emitting radionuclides such as 1C, 15O and 13N are produced in patient tissue. Using PET scanners, the isotopic activity distribution can be measured for in-vivo range verification. A second cyclotron, the TR13, provides 13 MeV protons onto liquid targets for the production of PET radionuclides such as 18F, 13N or 68Ga, for medical applications. The aim of this work was to validate Geant4 against FLUKA and experimental measurements for production of the above-mentioned isotopes using the two cyclotrons. The results show variable degrees of agreement. For proton therapy, the proton-range agreement was within 2 mm for 11C activity, whereas 13N disagreed. For liquid targets at the TR13 the average absolute deviation ratio between FLUKA and experiment was 1.9±2.7, whereas the average absolute deviation ratio between Geant4 and experiment was 0. 6±0.4. This is due to the uncertainties present in experimentally determined reaction cross sections.

  11. Absolute Ages and Distances of 22 GCs Using Monte Carlo Main-sequence Fitting

    NASA Astrophysics Data System (ADS)

    O'Malley, Erin M.; Gilligan, Christina; Chaboyer, Brian

    2017-04-01

    The recent Gaia Data Release 1 of stellar parallaxes provides ample opportunity to find metal-poor main-sequence stars with precise parallaxes. We select 21 such stars with parallax uncertainties better than σ π /π ≤ 0.10 and accurate abundance determinations suitable for testing metal-poor stellar evolution models and determining the distance to Galactic globular clusters (GCs). A Monte Carlo analysis was used, taking into account uncertainties in the model construction parameters, to generate stellar models and isochrones to fit to the calibration stars. The isochrones that fit the calibration stars best were then used to determine the distances and ages of 22 GCs with metallicities ranging from -2.4 dex to -0.7 dex. We find distances with an average uncertainty of 0.15 mag and absolute ages ranging from 10.8 to 13.6 Gyr with an average uncertainty of 1.6 Gyr. Using literature proper motion data, we calculate orbits for the clusters, finding six that reside within the Galactic disk/bulge, while the rest are considered halo clusters. We find no strong evidence for a relationship between age and Galactocentric distance, but we do find a decreasing age-[Fe/H] relation.

  12. Atmospheric Temperature Profile Measurements Using Mobile High Spectral Resolution Lidar

    NASA Astrophysics Data System (ADS)

    Razenkov, Ilya I.; Eloranta, Edwin W.

    2016-06-01

    The High Spectral Resolution Lidar (HSRL) designed at the University of Wisconsin-Madison discriminates between Mie and Rayleigh backscattering [1]. It exploits the Doppler effect caused by thermal motion of molecules, which broadens the spectrum of the transmitted laser light. That allows for absolute calibration of the lidar and measurements of the aerosol volume backscatter coefficient. Two iodine absorption filters with different absorption line widths (a regular iodine vapor filter and Argon buffered iodine filter) allow for atmospheric temperature profile measurements. The sensitivity of the measured signal-to-air temperature ratio is around 0.14%/K. The instrument uses a shared telescope transmitter-receiver design and operates in eyesafe mode (the product of laser average power and telescope aperture equals 0.1 Wm2 at 532 nm).

  13. Myocardial perfusion quantification using simultaneously acquired 13 NH3 -ammonia PET and dynamic contrast-enhanced MRI in patients at rest and stress.

    PubMed

    Kunze, Karl P; Nekolla, Stephan G; Rischpler, Christoph; Zhang, Shelley HuaLei; Hayes, Carmel; Langwieser, Nicolas; Ibrahim, Tareq; Laugwitz, Karl-Ludwig; Schwaiger, Markus

    2018-04-19

    Systematic differences with respect to myocardial perfusion quantification exist between DCE-MRI and PET. Using the potential of integrated PET/MRI, this study was conceived to compare perfusion quantification on the basis of simultaneously acquired 13 NH 3 -ammonia PET and DCE-MRI data in patients at rest and stress. Twenty-nine patients were examined on a 3T PET/MRI scanner. DCE-MRI was implemented in dual-sequence design and additional T 1 mapping for signal normalization. Four different deconvolution methods including a modified version of the Fermi technique were compared against 13 NH 3 -ammonia results. Cohort-average flow comparison yielded higher resting flows for DCE-MRI than for PET and, therefore, significantly lower DCE-MRI perfusion ratios under the common assumption of equal arterial and tissue hematocrit. Absolute flow values were strongly correlated in both slice-average (R 2  = 0.82) and regional (R 2  = 0.7) evaluations. Different DCE-MRI deconvolution methods yielded similar flow result with exception of an unconstrained Fermi method exhibiting outliers at high flows when compared with PET. Thresholds for Ischemia classification may not be directly tradable between PET and MRI flow values. Differences in perfusion ratios between PET and DCE-MRI may be lifted by using stress/rest-specific hematocrit conversion. Proper physiological constraints are advised in model-constrained deconvolution. © 2018 International Society for Magnetic Resonance in Medicine.

  14. Is telomere length a molecular marker of past thermal stress in wild fish?

    PubMed

    Debes, Paul V; Visse, Marko; Panda, Bineet; Ilmonen, Petteri; Vasemägi, Anti

    2016-11-01

    Telomeres protect eukaryotic chromosomes; variation in telomere length has been linked (primarily in homoeothermic animals) to variation in stress, cellular ageing and disease risk. Moreover, telomeres have been suggested to function as biomarker for quantifying past environmental stress, but studies in wild animals remain rare. Environmental stress, such as extreme environmental temperatures in poikilothermic animals, may result in oxidative stress that accelerates telomere attrition. However, growth, which may depend on temperature, can also contribute to telomere attrition. To test for associations between multitissue telomere length and past water temperature while accounting for the previous individual growth, we used quantitative PCR to analyse samples from 112 young-of-the-year brown trout from 10 natural rivers with average water temperature differences of up to 6°C (and an absolute maximum of 23°C). We found negative associations between relative telomere length (RTL) and both average river temperature and individual body size. We found no indication of RTL-temperature association differences among six tissues, but we did find indications for differences among the tissues for associations between RTL and body size; size trends, albeit nonsignificant in their differences, were strongest in muscle and weakest in fin. Although causal relationships among temperature, growth, oxidative stress, and cross-sectional telomere length remain largely unknown, our results indicate that telomere-length variation in a poikilothermic wild animal is associated with both past temperature and growth. © 2016 The Authors. Molecular Ecology Published by John Wiley & Sons Ltd.

  15. The Type Ia Supernova Color-Magnitude Relation and Host Galaxy Dust: A Simple Hierarchical Bayesian Model

    NASA Astrophysics Data System (ADS)

    Mandel, Kaisey; Scolnic, Daniel; Shariff, Hikmatali; Foley, Ryan; Kirshner, Robert

    2017-01-01

    Inferring peak optical absolute magnitudes of Type Ia supernovae (SN Ia) from distance-independent measures such as their light curve shapes and colors underpins the evidence for cosmic acceleration. SN Ia with broader, slower declining optical light curves are more luminous (“broader-brighter”) and those with redder colors are dimmer. But the “redder-dimmer” color-luminosity relation widely used in cosmological SN Ia analyses confounds its two separate physical origins. An intrinsic correlation arises from the physics of exploding white dwarfs, while interstellar dust in the host galaxy also makes SN Ia appear dimmer and redder. Conventional SN Ia cosmology analyses currently use a simplistic linear regression of magnitude versus color and light curve shape, which does not model intrinsic SN Ia variations and host galaxy dust as physically distinct effects, resulting in low color-magnitude slopes. We construct a probabilistic generative model for the dusty distribution of extinguished absolute magnitudes and apparent colors as the convolution of an intrinsic SN Ia color-magnitude distribution and a host galaxy dust reddening-extinction distribution. If the intrinsic color-magnitude (MB vs. B-V) slope βint differs from the host galaxy dust law RB, this convolution results in a specific curve of mean extinguished absolute magnitude vs. apparent color. The derivative of this curve smoothly transitions from βint in the blue tail to RB in the red tail of the apparent color distribution. The conventional linear fit approximates this effective curve near the average apparent color, resulting in an apparent slope βapp between βint and RB. We incorporate these effects into a hierarchical Bayesian statistical model for SN Ia light curve measurements, and analyze a dataset of SALT2 optical light curve fits of 277 nearby SN Ia at z < 0.10. The conventional linear fit obtains βapp ≈ 3. Our model finds a βint = 2.2 ± 0.3 and a distinct dust law of RB = 3.7 ± 0.3, consistent with the average for Milky Way dust, while correcting a systematic distance bias of ~0.10 mag in the tails of the apparent color distribution. This research is supported by NSF grants AST-156854, AST-1211196, and NASA grant NNX15AJ55G.

  16. PHYSICAL PROPERTIES OF LARGE AND SMALL GRANULES IN SOLAR QUIET REGIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu Daren; Xie Zongxia; Hu Qinghua

    The normal mode observations of seven quiet regions obtained by the Hinode spacecraft are analyzed to study the physical properties of granules. An artificial intelligence technique is introduced to automatically find the spatial distribution of granules in feature spaces. In this work, we investigate the dependence of granular continuum intensity, mean Doppler velocity, and magnetic fields on granular diameter. We recognized 71,538 granules by an automatic segmentation technique and then extracted five properties: diameter, continuum intensity, Doppler velocity, and longitudinal and transverse magnetic flux density to describe the granules. To automatically explore the intrinsic structures of the granules in themore » five-dimensional parameter space, the X-means clustering algorithm and one-rule classifier are introduced to define the rules for classifying the granules. It is found that diameter is a dominating parameter in classifying the granules and two families of granules are derived: small granules with diameters smaller than 1.''44, and large granules with diameters larger than 1.''44. Based on statistical analysis of the detected granules, the following results are derived: (1) the averages of diameter, continuum intensity, and Doppler velocity in the upward direction of large granules are larger than those of small granules; (2) the averages of absolute longitudinal, transverse, and unsigned flux density of large granules are smaller than those of small granules; (3) for small granules, the average of continuum intensity increases with their diameters, while the averages of Doppler velocity, transverse, absolute longitudinal, and unsigned magnetic flux density decrease with their diameters. However, the mean properties of large granules are stable; (4) the intensity distributions of all granules and small granules do not satisfy Gaussian distribution, while that of large granules almost agrees with normal distribution with a peak at 1.04 I{sub 0}.« less

  17. Adolescent Idiopathic Scoliosis Treatment by a Korean Neurosurgeon: The Changing Role for Neurosurgeons

    PubMed Central

    Kim, Woong-Beom; Park, Young-Seop; Kim, Ki-Jeong; Jahng, Tae-Ahn; Kim, Yongjung J.

    2015-01-01

    Objective The purpose of this study was to evaluate radiographic/clinical outcomes of adolescent idiopathic scoliosis (AIS) patients treated by a Korean neurosurgeon. Methods Ten AIS patients were treated by a single neurosurgeon between January 2011 and September 2013 utilizing segmental instrumentation with pedicle screws. Basic demographic information, curve pattern by Lenke classification, number of levels treated, amount of correction achieved, radiographic/clinical outcomes [by Scolisis Resarch Society (SRS-22r) questionnaire] and complications were evaluated to determine the surgical results. Pulmonary function test was utilized to assess forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) before and after surgery. Results The average percentage of correction of the major structural curve was 73.6% (ranged from 64% to 81.5%). Preoperative and final postoperative absolute FVC averaged 3.03 L and 3.76 L (0.73 L increase, p=0.046), and absolute FEV1 averaged 2.63 L and 3.49 L (0.86 L increase, p=0.021). Preoperative and final postoperative average self-image and function scores of SRS-22r were, 2.6±0.5, 3.3±0.1, 4.0±0.5, and 4.6±0.0, respectively. There was a significant improvement of the self-image and function scores of SRS-22r questionnaires before and after surgery (p<0.05). There was no case of neurological deficit, infection and revision for screw malposition. One patient underwent a fusion extension surgery for shoulder asymmetry. Conclusion Radiographic/clinical outcomes of AIS patients treated by a Korean neurosurgeon were acceptable. Fundamental understanding of pediatric spinal deformity is essential for the practice of AIS surgery. PMID:26279813

  18. Adolescent Idiopathic Scoliosis Treatment by a Korean Neurosurgeon: The Changing Role for Neurosurgeons.

    PubMed

    Hyun, Seung-Jae; Kim, Woong-Beom; Park, Young-Seop; Kim, Ki-Jeong; Jahng, Tae-Ahn; Kim, Yongjung J

    2015-07-01

    The purpose of this study was to evaluate radiographic/clinical outcomes of adolescent idiopathic scoliosis (AIS) patients treated by a Korean neurosurgeon. Ten AIS patients were treated by a single neurosurgeon between January 2011 and September 2013 utilizing segmental instrumentation with pedicle screws. Basic demographic information, curve pattern by Lenke classification, number of levels treated, amount of correction achieved, radiographic/clinical outcomes [by Scolisis Resarch Society (SRS-22r) questionnaire] and complications were evaluated to determine the surgical results. Pulmonary function test was utilized to assess forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) before and after surgery. The average percentage of correction of the major structural curve was 73.6% (ranged from 64% to 81.5%). Preoperative and final postoperative absolute FVC averaged 3.03 L and 3.76 L (0.73 L increase, p=0.046), and absolute FEV1 averaged 2.63 L and 3.49 L (0.86 L increase, p=0.021). Preoperative and final postoperative average self-image and function scores of SRS-22r were, 2.6±0.5, 3.3±0.1, 4.0±0.5, and 4.6±0.0, respectively. There was a significant improvement of the self-image and function scores of SRS-22r questionnaires before and after surgery (p<0.05). There was no case of neurological deficit, infection and revision for screw malposition. One patient underwent a fusion extension surgery for shoulder asymmetry. Radiographic/clinical outcomes of AIS patients treated by a Korean neurosurgeon were acceptable. Fundamental understanding of pediatric spinal deformity is essential for the practice of AIS surgery.

  19. A NEW METHOD TO QUANTIFY AND REDUCE THE NET PROJECTION ERROR IN WHOLE-SOLAR-ACTIVE-REGION PARAMETERS MEASURED FROM VECTOR MAGNETOGRAMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Falconer, David A.; Tiwari, Sanjiv K.; Moore, Ronald L.

    Projection errors limit the use of vector magnetograms of active regions (ARs) far from the disk center. In this Letter, for ARs observed up to 60° from the disk center, we demonstrate a method for measuring and reducing the projection error in the magnitude of any whole-AR parameter that is derived from a vector magnetogram that has been deprojected to the disk center. The method assumes that the center-to-limb curve of the average of the parameter’s absolute values, measured from the disk passage of a large number of ARs and normalized to each AR’s absolute value of the parameter atmore » central meridian, gives the average fractional projection error at each radial distance from the disk center. To demonstrate the method, we use a large set of large-flux ARs and apply the method to a whole-AR parameter that is among the simplest to measure: whole-AR magnetic flux. We measure 30,845 SDO /Helioseismic and Magnetic Imager vector magnetograms covering the disk passage of 272 large-flux ARs, each having whole-AR flux >10{sup 22} Mx. We obtain the center-to-limb radial-distance run of the average projection error in measured whole-AR flux from a Chebyshev fit to the radial-distance plot of the 30,845 normalized measured values. The average projection error in the measured whole-AR flux of an AR at a given radial distance is removed by multiplying the measured flux by the correction factor given by the fit. The correction is important for both the study of the evolution of ARs and for improving the accuracy of forecasts of an AR’s major flare/coronal mass ejection productivity.« less

  20. Pediatric invasive fungal rhinosinusitis: An investigation of 17 patients.

    PubMed

    Vinh, Daniel; Yim, Michael; Dutta, Ankhi; Jones, John K; Zhang, Wei; Sitton, Matthew

    2017-08-01

    To investigate outcomes of pediatric patients at a single institution with invasive fungal rhinosinusitis (IFRS) and to determine variables that impact overall survival. All pediatric patients at a large tertiary children's hospital diagnosed with IFRS confirmed by surgical pathology from 2009 to 2015 were retrospectively reviewed. Demographics, underlying diseases, symptoms, antifungal therapy, absolute neutrophil count (ANC), surgical management,and outcomes were analyzed. Seventeen patients were identified with IFRS with an average age of 8.7 years and 53% male. Hematologic malignancy was the most common (n = 13) underlying disease. The most common presenting symptoms were fever (82%) and congestion (41%). 15 patients had severe neutropenia (Absolute Neutrophil Count (ANC) < 500) within 2 weeks prior to diagnosis. The average ANC at time of diagnosis was 1420 cells/uL. 16 patients were treated with serial nasal endoscopy and debridement, while 1 patient was treated with an open approach. 16 received combination antifungals while 1 was treated with amphotericin monotherapy. The most common genus cultured was Fusarium (n = 6). The average number of surgical interventions was 3.4, with the average interval between interventions 6.2 days. 13 of 17 (76%) were cleared of IFRS. Overall survival at 6 months was 41%. Pediatric IFRS is a life-threatening disease that requires a coordinated surgical and medical approach. Despite a relatively high local control rate, overall mortality remains disappointingly high, reflecting the disease's underlying pathogenesis - lack of host defense and risk of disseminated fungal infection. Further investigation is necessary to reveal optimal management with regards to antifungal therapy, surgery, and utility of labs. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Changes Over Time in Absolute and Relative Socioeconomic Differences in Smoking: A Comparison of Cohort Studies From Britain, Finland, and Japan

    PubMed Central

    Pietiläinen, Olli; Ferrie, Jane; Kivimäki, Mika; Lahti, Jouni; Marmot, Michael; Rahkonen, Ossi; Sekine, Michikazu; Shipley, Martin; Tatsuse, Takashi; Lallukka, Tea

    2016-01-01

    Introduction: Socioeconomic differences in smoking over time and across national contexts are poorly understood. We assessed the magnitude of relative and absolute social class differences in smoking in cohorts from Britain, Finland, and Japan over 5–7 years. Methods: The British Whitehall II study (n = 4350), Finnish Helsinki Health Study (n = 6328), and Japanese Civil Servants Study (n = 1993) all included employed men and women aged 35–68 at baseline in 1997–2002. Follow-up was in 2003–2007 (mean follow-up 5.1, 6.5, and 3.6 years, respectively). Occupational social class (managers, professionals and clerical employees) was measured at baseline. Current smoking and covariates (age, marital status, body mass index, and self-rated health) were measured at baseline and follow-up. We assessed relative social class differences using the Relative Index of Inequality and absolute differences using the Slope Index of Inequality. Results: Social class differences in smoking were found in Britain and Finland, but not in Japan. Age-adjusted relative differences at baseline ranged from Relative Index of Inequality 3.08 (95% confidence interval 1.99–4.78) among Finnish men to 2.32 (1.24–4.32) among British women, with differences at follow-up greater by 8%–58%. Absolute differences remained stable and varied from Slope Index of Inequality 0.27 (0.15–0.40) among Finnish men to 0.10 (0.03–0.16) among British women. Further adjustment for covariates had modest effects on inequality indices. Conclusions: Large social class differences in smoking persisted among British and Finnish men and women, with widening tendencies in relative differences over time. No differences could be confirmed among Japanese men or women. Implications: Changes over time in social class differences in smoking are poorly understood across countries. Our study focused on employees from Britain, Finland and Japan, and found relative and absolute and class differences among British and Finnish men and women. Key covariates had modest effects on the differences. Relative differences tended to widen over the 4- to 7-year follow-up, whereas absolute differences remained stable. In contrast, class differences in smoking among Japanese men or women were not found. Britain and Finland are at the late stage of the smoking epidemic model, whereas Japan may not follow the same model. PMID:26764256

  2. Structural changes upon excitation of D1-D2-Cyt b559 photosystem II reaction centers depend on the beta-carotene content.

    PubMed

    Losi, Aba; Yruela, Inmaculada; Reus, Michael; Holzwarth, Alfred R; Braslavsky, Silvia E

    2003-07-01

    Different preparations of D1-D2-Cyt b559 complexes from spinach with different beta-carotene (Car) content [on average from <0.5 to 2 per reaction center (RC)] were studied by means of laser-induced optoacoustic spectroscopy. phiP680(+)Pheo(-) does not depend on the preparation (or on the Car content) inasmuch as the magnitude of the prompt heat (produced within 20 ns) does not vary for the different samples upon excitation at 675 and 620 nm. The energy level of the primary charge-separated state, P680(+)Pheo(-), was determined as EP680(+)Pheo(-) = 1.55 eV. Thus, an enthalpy change accompanying charge separation from excited P680 of deltaH*P680Pheo-->P680(+)Pheo(-) = -0.27 eV is obtained. Calculations using the heat evolved during the time-resolved decay of P680(+)Pheo(-) (< or = 100 ns) affords a triplet (3[P680Pheo]) quantum yield phi3[P680Pheo] = 0.5 +/- 0.14. The structural volume change, deltaV1, corresponding to the formation of P680(+)Pheo(-), strongly depends on the Car content; it is ca. -2.5 A3 molecule(-1) for samples with <0.5 Car on average, decreases (in absolute value) to -0.5 +/- 0.2 A3 for samples with an average of 1 Car, and remains the same for samples with two Cars per RC. This suggests that the Car molecules induce changes in the ground-state RC conformation, an idea which was confirmed by preferential excitation of Car with blue light, which produced different carotene triplet lifetimes in samples with 2 Car compared to those containing less carotene. We conclude that the two beta-carotenes are not structurally equivalent. Upon blue-light excitation (480 nm, preferential carotene absorption) the fraction of energy stored is ca. 60% for the 9Chl-2Car sample, whereas it is 40% for the preparations with one or less Cars on average, indicating different paths of energy distribution after Car excitation in these RCs with remaining chlorophyll antennae.

  3. Gravity data from the Sierra Vista Subwatershed, Upper San Pedro Basin, Arizona

    USGS Publications Warehouse

    Kennedy, Jeffrey R.

    2015-01-01

    This report (1) summarizes changes to the Sierra Vista Subwatershed regional time-lapse gravity network with respect to station locations and (2) presents 2014 and 2015 gravity measurements and gravity values at each station. A prior gravity network, established between 2000 and 2005, was revised in 2014 to cover a larger number of stations over a smaller geographic area in order to decrease measurement and interpolation uncertainty. The network currently consists of 59 gravity stations, including 14 absolute-gravity stations. Following above-average rainfall during summer 2014, gravity increased at all but one of the absolute-gravity stations that were observed in both June 2014 and January 2015. This increase in gravity indicates increased groundwater storage in the aquifer and (or) unsaturated zone as a result of rainfall and infiltration.

  4. Transport Structure and Energetic of the North Atlantic Current in Subpolar Gyre from Observations

    NASA Astrophysics Data System (ADS)

    Houpert, Loïc; Inall, Mark; Dumont, Estelle; Gary, Stefan; Porter, Marie; Johns, William; Cunningham, Stuart

    2017-04-01

    We present the first 2 years of UK-OSNAP glider missions on the Rockall Plateau in the North Atlantic subpolar gyre. From July 2014 to August 2016, 20 gliders sections were realized along 58°N, between 22°W and 15°W. Depth-averaged currents estimated from gliders show very strong values (up to 45cm.s-1) associated with meso-scale variability, due particularly to eddies and subpolar mode water formation. The variability of the flow on the eastern slope of the Iceland basin and on the Rockall Plateau is presented. Meridional absolute geostrophic transports are calculated from the glider data, and we discuss the vertical structure of the absolute meridional transport, especially the part associated with the North Atlantic Current.

  5. Dual-comb spectroscopy of molecular electronic transitions in condensed phases

    NASA Astrophysics Data System (ADS)

    Cho, Byungmoon; Yoon, Tai Hyun; Cho, Minhaeng

    2018-03-01

    Dual-comb spectroscopy (DCS) utilizes two phase-locked optical frequency combs to allow scanless acquisition of spectra using only a single point detector. Although recent DCS measurements demonstrate rapid acquisition of absolutely calibrated spectral lines with unprecedented precision and accuracy, complex phase-locking schemes and multiple coherent averaging present significant challenges for widespread adoption of DCS. Here, we demonstrate Global Positioning System (GPS) disciplined DCS of a molecular electronic transition in solution at around 800 nm, where the absorption spectrum is recovered by using a single time-domain interferogram. We anticipate that this simplified dual-comb technique with absolute time interval measurement and ultrabroad bandwidth will allow adoption of DCS to tackle molecular dynamics investigation through its implementation in time-resolved nonlinear spectroscopic studies and coherent multidimensional spectroscopy of coupled chromophore systems.

  6. Expected indoor 222Rn levels in counties with very high and very low lung cancer rates.

    PubMed

    Cohen, B L

    1989-12-01

    Counties in the U.S. with high lung cancer rates should have higher average 222Rn levels than counties with low lung cancer rates, assuming the average 222Rn level in a county is not correlated with other factors that cause lung cancer. The magnitude of this effect was calculated, using the absolute risk model, the relative risk model, and an intermediate model, for females who died in 1950-1969. The results were similar for all three models. We concluded that, ignoring migration, the average Rn level in the highest lung cancer counties should be about three times higher than in the lowest lung cancer counties according to the theory. Preliminary data are presented indicating that the situation is quite the opposite: The average Rn level in the highest lung cancer counties was only about one-half that in the lowest lung cancer counties.

  7. Comparison of Online 6 Degree-of-Freedom Image Registration of Varian TrueBeam Cone-Beam CT and BrainLab ExacTrac X-Ray for Intracranial Radiosurgery.

    PubMed

    Li, Jun; Shi, Wenyin; Andrews, David; Werner-Wasik, Maria; Lu, Bo; Yu, Yan; Dicker, Adam; Liu, Haisong

    2017-06-01

    The study was aimed to compare online 6 degree-of-freedom image registrations of TrueBeam cone-beam computed tomography and BrainLab ExacTrac X-ray imaging systems for intracranial radiosurgery. Phantom and patient studies were performed on a Varian TrueBeam STx linear accelerator (version 2.5), which is integrated with a BrainLab ExacTrac imaging system (version 6.1.1). The phantom study was based on a Rando head phantom and was designed to evaluate isocenter location dependence of the image registrations. Ten isocenters at various locations representing clinical treatment sites were selected in the phantom. Cone-beam computed tomography and ExacTrac X-ray images were taken when the phantom was located at each isocenter. The patient study included 34 patients. Cone-beam computed tomography and ExacTrac X-ray images were taken at each patient's treatment position. The 6 degree-of-freedom image registrations were performed on cone-beam computed tomography and ExacTrac, and residual errors calculated from cone-beam computed tomography and ExacTrac were compared. In the phantom study, the average residual error differences (absolute values) between cone-beam computed tomography and ExacTrac image registrations were 0.17 ± 0.11 mm, 0.36 ± 0.20 mm, and 0.25 ± 0.11 mm in the vertical, longitudinal, and lateral directions, respectively. The average residual error differences in the rotation, roll, and pitch were 0.34° ± 0.08°, 0.13° ± 0.09°, and 0.12° ± 0.10°, respectively. In the patient study, the average residual error differences in the vertical, longitudinal, and lateral directions were 0.20 ± 0.16 mm, 0.30 ± 0.18 mm, 0.21 ± 0.18 mm, respectively. The average residual error differences in the rotation, roll, and pitch were 0.40°± 0.16°, 0.17° ± 0.13°, and 0.20° ± 0.14°, respectively. Overall, the average residual error differences were <0.4 mm in the translational directions and <0.5° in the rotational directions. ExacTrac X-ray image registration is comparable to TrueBeam cone-beam computed tomography image registration in intracranial treatments.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stassi, D.; Ma, H.; Schmidt, T. G., E-mail: taly.gilat-schmidt@marquette.edu

    Purpose: Reconstructing a low-motion cardiac phase is expected to improve coronary artery visualization in coronary computed tomography angiography (CCTA) exams. This study developed an automated algorithm for selecting the optimal cardiac phase for CCTA reconstruction. The algorithm uses prospectively gated, single-beat, multiphase data made possible by wide cone-beam imaging. The proposed algorithm differs from previous approaches because the optimal phase is identified based on vessel image quality (IQ) directly, compared to previous approaches that included motion estimation and interphase processing. Because there is no processing of interphase information, the algorithm can be applied to any sampling of image phases, makingmore » it suited for prospectively gated studies where only a subset of phases are available. Methods: An automated algorithm was developed to select the optimal phase based on quantitative IQ metrics. For each reconstructed slice at each reconstructed phase, an image quality metric was calculated based on measures of circularity and edge strength of through-plane vessels. The image quality metric was aggregated across slices, while a metric of vessel-location consistency was used to ignore slices that did not contain through-plane vessels. The algorithm performance was evaluated using two observer studies. Fourteen single-beat cardiac CT exams (Revolution CT, GE Healthcare, Chalfont St. Giles, UK) reconstructed at 2% intervals were evaluated for best systolic (1), diastolic (6), or systolic and diastolic phases (7) by three readers and the algorithm. Pairwise inter-reader and reader-algorithm agreement was evaluated using the mean absolute difference (MAD) and concordance correlation coefficient (CCC) between the reader and algorithm-selected phases. A reader-consensus best phase was determined and compared to the algorithm selected phase. In cases where the algorithm and consensus best phases differed by more than 2%, IQ was scored by three readers using a five point Likert scale. Results: There was no statistically significant difference between inter-reader and reader-algorithm agreement for either MAD or CCC metrics (p > 0.1). The algorithm phase was within 2% of the consensus phase in 15/21 of cases. The average absolute difference between consensus and algorithm best phases was 2.29% ± 2.47%, with a maximum difference of 8%. Average image quality scores for the algorithm chosen best phase were 4.01 ± 0.65 overall, 3.33 ± 1.27 for right coronary artery (RCA), 4.50 ± 0.35 for left anterior descending (LAD) artery, and 4.50 ± 0.35 for left circumflex artery (LCX). Average image quality scores for the consensus best phase were 4.11 ± 0.54 overall, 3.44 ± 1.03 for RCA, 4.39 ± 0.39 for LAD, and 4.50 ± 0.18 for LCX. There was no statistically significant difference (p > 0.1) between the image quality scores of the algorithm phase and the consensus phase. Conclusions: The proposed algorithm was statistically equivalent to a reader in selecting an optimal cardiac phase for CCTA exams. When reader and algorithm phases differed by >2%, image quality as rated by blinded readers was statistically equivalent. By detecting the optimal phase for CCTA reconstruction, the proposed algorithm is expected to improve coronary artery visualization in CCTA exams.« less

  9. Minor planets and related objects. XXI - Photometry of eight asteroids

    NASA Technical Reports Server (NTRS)

    Taylor, R. C.; Gehrels, T.; Capen, R. C.

    1976-01-01

    Light curves, UBV colors, rotational periods, phase coefficients, and absolute magnitudes are presented. The asteroids studied are (1) Ceres, (4) Vesta, (16) Psyche, (78) Diana, (281) Lucretia, (451) Patientia, (1212) Francette, and (1362) Griqua. The rotation axis of Lucretia is nearly perpendicular to the plane of the ecliptic. Ceres appears to be nearly spherical with an absolute magnitude of B(1,0)=4.42, which is 0.3 mag fainter than previously reported. The determination of the absolute magnitude for an asteroid depends on its aspect, and for each opposition there is, therefore, a different absolute magnitude.

  10. On the accuracy of the Head Impact Telemetry (HIT) System used in football helmets.

    PubMed

    Jadischke, Ron; Viano, David C; Dau, Nathan; King, Albert I; McCarthy, Joe

    2013-09-03

    On-field measurement of head impacts has relied on the Head Impact Telemetry (HIT) System, which uses helmet mounted accelerometers to determine linear and angular head accelerations. HIT is used in youth and collegiate football to assess the frequency and severity of helmet impacts. This paper evaluates the accuracy of HIT for individual head impacts. Most HIT validations used a medium helmet on a Hybrid III head. However, the appropriate helmet is large based on the Hybrid III head circumference (58 cm) and manufacturer's fitting instructions. An instrumented skull cap was used to measure the pressure between the head of football players (n=63) and their helmet. The average pressure with a large helmet on the Hybrid III was comparable to the average pressure from helmets used by players. A medium helmet on the Hybrid III produced average pressures greater than the 99th percentile volunteer pressure level. Linear impactor tests were conducted using a large and medium helmet on the Hybrid III. Testing was conducted by two independent laboratories. HIT data were compared to data from the Hybrid III equipped with a 3-2-2-2 accelerometer array. The absolute and root mean square error (RMSE) for HIT were computed for each impact (n=90). Fifty-five percent (n=49) had an absolute error greater than 15% while the RMSE was 59.1% for peak linear acceleration. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Absolute Wavelength Calibration of the IDSII Spectrometer for Impurity Ion Velocity Measurements in the MST

    NASA Astrophysics Data System (ADS)

    Baltzer, M.; Craig, D.; den Hartog, D. J.; Nornberg, M. D.; MST Team

    2014-10-01

    The MST operates two Ion Doppler Spectrometers (IDS) for high time-resolution passive and active measurements of impurity ion emission. Absolutely calibrated measurements of flow are difficult because the spectrometers record data within 0.3 nm of the line of interest, and commercial calibration lamps do not produce lines in this narrow range . Four calibration methods were investigated. First, emission along the chord bisecting the poloidal plane was measured as it should have no time-averaged Doppler shift. Second, a calibrated CCD spectrometer and the IDSII were used to observe the same plasma from opposing sides so as to measure opposite Doppler shifts. The unshifted line is located halfway between the two opposing measurements. Third, the two fibers of the IDSI were positioned to take absolute flow measurements using opposing views. Substituting the IDSII for one of the IDSI fibers, absolute measurements of flow from the IDSI were used to calibrate the IDSII. Finally, an optical system was designed to filter an ultraviolet LED, providing a known wavelength source within the spectral range covered by the IDSII. The optical train is composed of an air-gapped etalon and fused silica lenses. The quality of calibration for each of these methods is analyzed and their results compared. Preliminary impurity ion velocity measurements are shown. This work has been supported by the US DOE and the NSF.

  12. Absolute pitch among American and Chinese conservatory students: prevalence differences, and evidence for a speech-related critical period.

    PubMed

    Deutsch, Diana; Henthorn, Trevor; Marvin, Elizabeth; Xu, HongShuai

    2006-02-01

    Absolute pitch is extremely rare in the U.S. and Europe; this rarity has so far been unexplained. This paper reports a substantial difference in the prevalence of absolute pitch in two normal populations, in a large-scale study employing an on-site test, without self-selection from within the target populations. Music conservatory students in the U.S. and China were tested. The Chinese subjects spoke the tone language Mandarin, in which pitch is involved in conveying the meaning of words. The American subjects were nontone language speakers. The earlier the age of onset of musical training, the greater the prevalence of absolute pitch; however, its prevalence was far greater among the Chinese than the U.S. students for each level of age of onset of musical training. The findings suggest that the potential for acquiring absolute pitch may be universal, and may be realized by enabling infants to associate pitches with verbal labels during the critical period for acquisition of features of their native language.

  13. A comparison of entropy balance and probability weighting methods to generalize observational cohorts to a population: a simulation and empirical example.

    PubMed

    Harvey, Raymond A; Hayden, Jennifer D; Kamble, Pravin S; Bouchard, Jonathan R; Huang, Joanna C

    2017-04-01

    We compared methods to control bias and confounding in observational studies including inverse probability weighting (IPW) and stabilized IPW (sIPW). These methods often require iteration and post-calibration to achieve covariate balance. In comparison, entropy balance (EB) optimizes covariate balance a priori by calibrating weights using the target's moments as constraints. We measured covariate balance empirically and by simulation by using absolute standardized mean difference (ASMD), absolute bias (AB), and root mean square error (RMSE), investigating two scenarios: the size of the observed (exposed) cohort exceeds the target (unexposed) cohort and vice versa. The empirical application weighted a commercial health plan cohort to a nationally representative National Health and Nutrition Examination Survey target on the same covariates and compared average total health care cost estimates across methods. Entropy balance alone achieved balance (ASMD ≤ 0.10) on all covariates in simulation and empirically. In simulation scenario I, EB achieved the lowest AB and RMSE (13.64, 31.19) compared with IPW (263.05, 263.99) and sIPW (319.91, 320.71). In scenario II, EB outperformed IPW and sIPW with smaller AB and RMSE. In scenarios I and II, EB achieved the lowest mean estimate difference from the simulated population outcome ($490.05, $487.62) compared with IPW and sIPW, respectively. Empirically, only EB differed from the unweighted mean cost indicating IPW, and sIPW weighting was ineffective. Entropy balance demonstrated the bias-variance tradeoff achieving higher estimate accuracy, yet lower estimate precision, compared with IPW methods. EB weighting required no post-processing and effectively mitigated observed bias and confounding. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Wenzhong; Yi, Ji; Chen, Siyu

    Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (smallmore » ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.« less

  15. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length

    PubMed Central

    Liu, Wenzhong; Yi, Ji; Chen, Siyu; Jiao, Shuliang; Zhang, Hao F.

    2015-01-01

    Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length. PMID:26328984

  16. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length.

    PubMed

    Liu, Wenzhong; Yi, Ji; Chen, Siyu; Jiao, Shuliang; Zhang, Hao F

    2015-09-01

    Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as -0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31 μl/min among four wild-type rats. The authors' measured flow rates were consistent with results in the literature. By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.

  17. Associations between disability prevalence and local-area characteristics in a general community-living population.

    PubMed

    Philibert, M D; Pampalon, R; Hamel, D; Daniel, M

    2013-10-01

    Disability is understood to arise from person-environment interactions. Hence, heterogeneity in local-area characteristics should be associated with local-area variation in disability prevalence. This study evaluated the associations of disability prevalence with local-area socioeconomic status and contextual features. Disability prevalence was obtained from the Canada census of 2001 for the entire province of Québec at the level of dissemination areas (617 individuals on average) based on responses from 20% of the population. Data on local-area characteristics were urban-rural denomination, social and material deprivation, active and collective commuting, residential stability, and housing quality. Associations between local-area characteristics and disability prevalence were assessed using multilevel logistic regressions. Disability was associated with local-area socioeconomic status and contextual characteristics, and heterogeneity in these factors accounted for urban-rural differences in disability prevalence. Associations between contextual features and disability prevalence were confounded by local-area socioeconomic status. Some associations between local-area socioeconomic status and disability prevalence were moderated by contextual characteristics. The importance of this effect modification is greater when expressed in terms of the absolute magnitude of disability than in the relative likelihood of disability. Explanation of rural-urban differences by the contribution of other local-area characteristics is consistent with the conceptualization of urban-rural categories as the reflection of spatially varying ensembles of compositional and contextual factors. Although local-area socioeconomic status explains most variability in disability prevalence, this study shows that contextual characteristics are relevant to analyses of the spatial patterning of disability as they predict spatial variations of disability, sometimes in interaction with socioeconomic status. This study demonstrates that absolute and relative perspectives on effect modification may lead to differing conclusions. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  18. Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 04: On 3D Fabrication of Phantoms and Experimental Verification of Patient Dose Computation Algorithms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khan, Rao; Zavan, Rodolfo; McGeachy, Philip

    2016-08-15

    Purpose: Transport based dose calculation algorithm Acuros XB (AXB) has been shown to accurately account for heterogeneities mostly through comparisons with Monte Carlo simulations. This study aims at providing additional experimental verification for AXB for flattened and unflattened clinical energies in low density phantoms of the same material. Materials and Methods: Polystyrene slabs were created using a bench-top 3D printer. Six slabs were printed at varying densities from 0.23 g/cm{sup 3} to 0.68 g/cm{sup 3}, corresponding to different density humanoid tissues. The slabs were used to form different single and multilayer geometries. Dose was calculated with AXB 11.0.31 for 6MV,more » 15MV flattened and 6FFF (flattening filter free) energies for field sizes of 2×2 cm{sup 2} and 5×5 cm{sup 2}. The phantoms containing radiochromic EBT3 films were irradiated. Absolute dose profiles and 2D gamma analyses were performed for 96 dose planes. Results: For all single slab, multislab configurations and energies, absolute dose differences between the AXB calculation and film measurements remained <3% for both fields, with slightly poor disagreement in penumbra. The gamma index at 2% / 2mm averaged 98% in all combinations of fields, phantoms and photon energies. Conclusions: The transport based dose algorithm AXB is in good agreement with the experimental measurements for small field sizes using 6MV, 6FFF and 15MV beams adjacent to low density heterogeneous media. This work provides sufficient experimental ground to support the use of AXB for heterogeneous dose calculation purposes.« less

  19. A comparison of two hospital districts with low and high figures in the compulsory care of minors: an ecological study.

    PubMed

    Siponen, Ulla; Välimäki, Maritta; Kaivosoja, Matti; Marttunen, Mauri; Kaltiala-Heino, Riittakerttu

    2011-08-01

    The last decade in Finland has seen a vast increase both in involuntary psychiatric treatment of adolescents and in the numbers of adolescents taken into care under the Child Welfare Act. Moreover, the variation in figures between different hospital districts is remarkable. The reasons for this are not known, but it cannot be due to variation in the epidemiology of mental disorders in minors. The aim of the study was to explore features associated with compulsory care of adolescents at regional level by comparing two hospital districts clearly differing in this regard. The characteristics of involuntarily treated adolescents and adolescents taken into care, the resources and structures of adolescent psychiatric services and child welfare services, and the environmental factors associated with adolescent well-being and adaptation, such as indicators of social deprivation of families were all considered. For the present study, 2 out of the 22 hospital districts in Finland were selected, one using compulsory psychiatric care and taking into care of 13-17-year olds above and the other below the average in Finland. Register data on patient characteristics, services, and social deprivation were used. Absolute and population adjusted figures (95% confidence intervals) from the variables are given. The differences in incidences between health care districts were compared using Poisson regression analysis. Proportions of divorces, single parent families, social exclusion and outpatient mental health service use, and detoxification treatment use of adults were higher in the health care district with above average coercion figures than in the area with below average coercion figures. The numbers of adolescent psychiatric outpatient visits were higher in the health care district with coercion figures below average despite the fact that the number of positions in adolescent outpatient services was lower than in the health care district with above average coercion figures. Factors other than the characteristics of the adolescents themselves are associated with use of compulsory care on them, although an ecological study design cannot establish causality.

  20. Absolute vs. Weight-Related Maximum Oxygen Uptake in Firefighters: Fitness Evaluation with and without Protective Clothing and Self-Contained Breathing Apparatus among Age Group

    PubMed Central

    Perroni, Fabrizio; Guidetti, Laura; Cignitti, Lamberto; Baldari, Carlo

    2015-01-01

    During fire emergencies, firefighters wear personal protective devices (PC) and a self-contained breathing apparatus (S.C.B.A.) to be protected from injuries. The purpose of this study was to investigate the differences of aerobic level in 197 firefighters (age: 34±7 yr; BMI: 24.4±2.3 kg.m-2), evaluated by a Queen’s College Step field Test (QCST), performed with and without fire protective garments, and to analyze the differences among age groups (<25 yr; 26-30 yr, 31-35 yr, 36-40 yr and >40 yr). Variance analysis was applied to assess differences (p < 0.05) between tests and age groups observed in absolute and weight-related values, while a correlation was examined between QCST with and without PC+S.C.B.A. The results have shown that a 13% of firefighters failed to complete the test with PC+S.C.B.A. and significant differences between QCST performed with and without PC+S.C.B.A. in absolute (F(1,169) = 42.6, p < 0.0001) and weight-related (F(1,169) = 339.9, p < 0.0001) terms. A better correlation has been found in L•min-1 (r=0.67) than in ml•kg-1•min-1 (r=0.54). Moreover, we found significant differences among age groups both in absolute and weight-related values. The assessment of maximum oxygen uptake of firefighters in absolute term can be a useful tool to evaluate the firefighters' cardiovascular strain. PMID:25764201

  1. [Definition and validation of a comfort index calculation method for office seats].

    PubMed

    Taboga, P; Marcolin, F; Bordignon, M; Antonutto, G

    2012-01-01

    Among its other required features, a highly comfortable chair should adapt its contact surfaces, namely the seat and the back rest, to the shape of the body of the person sitting on it. However, "comfort" is not usually perceived as an absolute value, but is derived from a subjective comparison between two or more chairs. The purpose of this research was the definition of an objective comfort index (IC), i.e., derived from instrumental measurements, and which would also represent an absolute comfort value. Analytical evaluation of the distribution of body weight, by means of a barometric matrix, shows that a comfortable chair tends to minimize peak and average values of pressure at the level of the contact areas located between the body and the seat and the back of the chair. To define a comparison parameter for determining an absolute comfort value, a reference chair (SDR) was developed. The seat and the back of this chair are rigid, with poor compliance. A comfort value of zero was, by definition, assigned to this chair. Therefore, the Comfort index (IC) was obtained by the mathematical calculation of the ratios of averages, peaks and gradients of pressure, appropriately weighted, and the corresponding values measured on the tested chair and on the SDR. It is shown that the anthropometric characteristics of each subject are irrelevant to the assessment of the IC, which depends only on the compliance characteristics of the seat and back surfaces of the tested chair IC can be improved through analysis of a larger number of seats, which would thus constitute the basis for the use of an objective evaluation of seating comfort.

  2. Comparison of measured and modelled negative hydrogen ion densities at the ECR-discharge HOMER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rauner, D.; Kurutz, U.; Fantz, U.

    2015-04-08

    As the negative hydrogen ion density n{sub H{sup −}} is a key parameter for the investigation of negative ion sources, its diagnostic quantification is essential in source development and operation as well as for fundamental research. By utilizing the photodetachment process of negative ions, generally two different diagnostic methods can be applied: via laser photodetachment, the density of negative ions is measured locally, but only relatively to the electron density. To obtain absolute densities, the electron density has to be measured additionally, which induces further uncertainties. Via cavity ring-down spectroscopy (CRDS), the absolute density of H{sup −} is measured directly,more » however LOS-averaged over the plasma length. At the ECR-discharge HOMER, where H{sup −} is produced in the plasma volume, laser photodetachment is applied as the standard method to measure n{sub H{sup −}}. The additional application of CRDS provides the possibility to directly obtain absolute values of n{sub H{sup −}}, thereby successfully bench-marking the laser photodetachment system as both diagnostics are in good agreement. In the investigated pressure range from 0.3 to 3 Pa, the measured negative hydrogen ion density shows a maximum at 1 to 1.5 Pa and an approximately linear response to increasing input microwave powers from 200 up to 500 W. Additionally, the volume production of negative ions is 0-dimensionally modelled by balancing H{sup −} production and destruction processes. The modelled densities are adapted to the absolute measurements of n{sub H{sup −}} via CRDS, allowing to identify collisions of H{sup −} with hydrogen atoms (associative and non-associative detachment) to be the dominant loss process of H{sup −} in the plasma volume at HOMER. Furthermore, the characteristic peak of n{sub H{sup −}} observed at 1 to 1.5 Pa is identified to be caused by a comparable behaviour of the electron density with varying pressure, as n{sub e} determines the volume production rate via dissociative electron attachment to vibrationally excited hydrogen molecules.« less

  3. VizieR Online Data Catalog: Yale Trigonometric Parallaxes Preliminary (van Altena+ 1991)

    NASA Astrophysics Data System (ADS)

    van Altena, W. F.; Lee, J. T.; Hoffleit, D.

    1995-10-01

    The preliminary edition of the General Catalogue of Trigonometric Stellar Parallaxes, containing 15349 parallaxes for 7879 stars, has been prepared at the Yale University Observatory. In this edition 1480 stars have been added to those contained in the previous edition of the catalog by Jenkins (1952, 1963). This relatively small increase in the number of stars is more than compensated for by the increased accuracy of the newer trigonometric parallaxes. The authors have attempted to include here all trigonometric parallaxes made available to them by March 1991 and will provide for each listed parallax in the final version the reference to its source of publication. For each star it lists the equatorial coordinates for B1900 and the secular variation for 100 years, the proper motion in x and y, the weighted average absolute parallax and its standard error, the number of parallax observations, the quality of interagreement among the different values, the visual magnitude, and various cross identifications with other catalogs. The B1900 equinox has been maintained to avoid assigning yet another star number. Ancillary information, including UBV photometry, MK spectral types, data on the variability and binary nature of the stars, orbits when available, and miscellaneous information to aid in determining the reliability of the data, will be listed in the final version. The relative parallaxes are corrected to absolute parallax using newly computed corrections that are based on an improved model of the galaxy. An analysis of the resulting absolute parallaxes has been made to study the accidental and systematic errors of the parallaxes. The results of that investigation are used to arrive at a weighting system for the catalog, which then yields weighted absolute parallaxes for each star. The weighting system is still under investigation; therefore, the weighted parallaxes may change a bit in the final version. Printed copies of the catalog will be available from the Yale University Observatory when the work has been completed (late 1993?). See the file cdrom.doc which provides the original documentation by W. van Altena. (1 data file).

  4. 40 CFR 53.56 - Test for effect of variations in ambient pressure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the tests and shall be checked at zero and at least one flow rate within ±3 percent of 16.7 L/min... this test, the absolute difference in values calculated in Equation 21 of this paragraph (g)(4) must... absolute difference between the mean ambient air pressure indicated by the test sampler and the ambient...

  5. 40 CFR 53.56 - Test for effect of variations in ambient pressure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the tests and shall be checked at zero and at least one flow rate within ±3 percent of 16.7 L/min... this test, the absolute difference in values calculated in Equation 21 of this paragraph (g)(4) must... absolute difference between the mean ambient air pressure indicated by the test sampler and the ambient...

  6. 40 CFR 53.56 - Test for effect of variations in ambient pressure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the tests and shall be checked at zero and at least one flow rate within ±3 percent of 16.7 L/min... this test, the absolute difference in values calculated in Equation 21 of this paragraph (g)(4) must... absolute difference between the mean ambient air pressure indicated by the test sampler and the ambient...

  7. 40 CFR 53.56 - Test for effect of variations in ambient pressure.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the tests and shall be checked at zero and at least one flow rate within ±3 percent of 16.7 L/min... this test, the absolute difference in values calculated in Equation 21 of this paragraph (g)(4) must... absolute difference between the mean ambient air pressure indicated by the test sampler and the ambient...

  8. Determination of the absolute molecular weight averages and molecular weight distributions of alginates used as ice cream stabilizers by using multiangle laser light scattering measurements.

    PubMed

    Turquois, T; Gloria, H

    2000-11-01

    High-performance size exclusion chromatography with multiangle laser light scattering detection (HPSEC-MALLS) was used for characterizing complete molecular weight distributions for a range of commercial alginates used as ice cream stabilizers. For the samples investigated, molecular weight averages were found to vary between 115 000 and 321 700 g/mol and polydispersity indexes varied from 1. 53 to 3.25. These samples displayed a high content of low molecular weights. Thus, the weight percentage of material below 100 000 g/mol ranged between 6.9 and 54.4%.

  9. Demand Forecasting: An Evaluation of DODs Accuracy Metric and Navys Procedures

    DTIC Science & Technology

    2016-06-01

    inventory management improvement plan, mean of absolute scaled error, lead time adjusted squared error, forecast accuracy, benchmarking, naïve method...Manager JASA Journal of the American Statistical Association LASE Lead-time Adjusted Squared Error LCI Life Cycle Indicator MA Moving Average MAE...Mean Squared Error xvi NAVSUP Naval Supply Systems Command NDAA National Defense Authorization Act NIIN National Individual Identification Number

  10. Comparison of the WSA-ENLIL model with three CME cone types

    NASA Astrophysics Data System (ADS)

    Jang, Soojeong; Moon, Y.; Na, H.

    2013-07-01

    We have made a comparison of the CME-associated shock propagation based on the WSA-ENLIL model with three cone types using 29 halo CMEs from 2001 to 2002. These halo CMEs have cone model parameters as well as their associated interplanetary (IP) shocks. For this study we consider three different cone types (an asymmetric cone model, an ice-cream cone model and an elliptical cone model) to determine 3-D CME parameters (radial velocity, angular width and source location), which are the input values of the WSA-ENLIL model. The mean absolute error (MAE) of the arrival times for the asymmetric cone model is 10.6 hours, which is about 1 hour smaller than those of the other models. Their ensemble average of MAE is 9.5 hours. However, this value is still larger than that (8.7 hours) of the empirical model of Kim et al. (2007). We will compare their IP shock velocities and densities with those from ACE in-situ measurements and discuss them in terms of the prediction of geomagnetic storms.Abstract (2,250 Maximum Characters): We have made a comparison of the CME-associated shock propagation based on the WSA-ENLIL model with three cone types using 29 halo CMEs from 2001 to 2002. These halo CMEs have cone model parameters as well as their associated interplanetary (IP) shocks. For this study we consider three different cone types (an asymmetric cone model, an ice-cream cone model and an elliptical cone model) to determine 3-D CME parameters (radial velocity, angular width and source location), which are the input values of the WSA-ENLIL model. The mean absolute error (MAE) of the arrival times for the asymmetric cone model is 10.6 hours, which is about 1 hour smaller than those of the other models. Their ensemble average of MAE is 9.5 hours. However, this value is still larger than that (8.7 hours) of the empirical model of Kim et al. (2007). We will compare their IP shock velocities and densities with those from ACE in-situ measurements and discuss them in terms of the prediction of geomagnetic storms.

  11. Global, regional, and national age-sex specific all-cause and cause-specific mortality for 240 causes of death, 1990-2013: a systematic analysis for the Global Burden of Disease Study 2013.

    PubMed

    2015-01-10

    Up-to-date evidence on levels and trends for age-sex-specific all-cause and cause-specific mortality is essential for the formation of global, regional, and national health policies. In the Global Burden of Disease Study 2013 (GBD 2013) we estimated yearly deaths for 188 countries between 1990, and 2013. We used the results to assess whether there is epidemiological convergence across countries. We estimated age-sex-specific all-cause mortality using the GBD 2010 methods with some refinements to improve accuracy applied to an updated database of vital registration, survey, and census data. We generally estimated cause of death as in the GBD 2010. Key improvements included the addition of more recent vital registration data for 72 countries, an updated verbal autopsy literature review, two new and detailed data systems for China, and more detail for Mexico, UK, Turkey, and Russia. We improved statistical models for garbage code redistribution. We used six different modelling strategies across the 240 causes; cause of death ensemble modelling (CODEm) was the dominant strategy for causes with sufficient information. Trends for Alzheimer's disease and other dementias were informed by meta-regression of prevalence studies. For pathogen-specific causes of diarrhoea and lower respiratory infections we used a counterfactual approach. We computed two measures of convergence (inequality) across countries: the average relative difference across all pairs of countries (Gini coefficient) and the average absolute difference across countries. To summarise broad findings, we used multiple decrement life-tables to decompose probabilities of death from birth to exact age 15 years, from exact age 15 years to exact age 50 years, and from exact age 50 years to exact age 75 years, and life expectancy at birth into major causes. For all quantities reported, we computed 95% uncertainty intervals (UIs). We constrained cause-specific fractions within each age-sex-country-year group to sum to all-cause mortality based on draws from the uncertainty distributions. Global life expectancy for both sexes increased from 65.3 years (UI 65.0-65.6) in 1990, to 71.5 years (UI 71.0-71.9) in 2013, while the number of deaths increased from 47.5 million (UI 46.8-48.2) to 54.9 million (UI 53.6-56.3) over the same interval. Global progress masked variation by age and sex: for children, average absolute differences between countries decreased but relative differences increased. For women aged 25-39 years and older than 75 years and for men aged 20-49 years and 65 years and older, both absolute and relative differences increased. Decomposition of global and regional life expectancy showed the prominent role of reductions in age-standardised death rates for cardiovascular diseases and cancers in high-income regions, and reductions in child deaths from diarrhoea, lower respiratory infections, and neonatal causes in low-income regions. HIV/AIDS reduced life expectancy in southern sub-Saharan Africa. For most communicable causes of death both numbers of deaths and age-standardised death rates fell whereas for most non-communicable causes, demographic shifts have increased numbers of deaths but decreased age-standardised death rates. Global deaths from injury increased by 10.7%, from 4.3 million deaths in 1990 to 4.8 million in 2013; but age-standardised rates declined over the same period by 21%. For some causes of more than 100,000 deaths per year in 2013, age-standardised death rates increased between 1990 and 2013, including HIV/AIDS, pancreatic cancer, atrial fibrillation and flutter, drug use disorders, diabetes, chronic kidney disease, and sickle-cell anaemias. Diarrhoeal diseases, lower respiratory infections, neonatal causes, and malaria are still in the top five causes of death in children younger than 5 years. The most important pathogens are rotavirus for diarrhoea and pneumococcus for lower respiratory infections. Country-specific probabilities of death over three phases of life were substantially varied between and within regions. For most countries, the general pattern of reductions in age-sex specific mortality has been associated with a progressive shift towards a larger share of the remaining deaths caused by non-communicable disease and injuries. Assessing epidemiological convergence across countries depends on whether an absolute or relative measure of inequality is used. Nevertheless, age-standardised death rates for seven substantial causes are increasing, suggesting the potential for reversals in some countries. Important gaps exist in the empirical data for cause of death estimates for some countries; for example, no national data for India are available for the past decade. Bill & Melinda Gates Foundation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Mesospheric circulation at the cloud top level of Venus according to Venus Monitoring Camera images

    NASA Astrophysics Data System (ADS)

    Khatuntsev, Igor; Patsaeva, Marina; Ignatiev, Nikolay; Titov, Dmitri; Markiewicz, Wojciech; Turin, Alexander

    We present results of wind speed measurements at the cloud top level of Venus derived from manual cloud tracking in the UV (365 nm) and IR (965 nm) channels of the Venus Monitoring Camera Experiment (VMC) [1] on board the Venus Express mission. Cloud details have a maximal contrast in the UV range. More then 90 orbits have been processed. 30000 manual vectors were obtained. The period of the observations covers more than 4 venusian year. Zonal wind speed demonstrates the local solar time dependence. Possible diurnal and semidiurnal components are observed [2]. According to averaged latitude profile of winds at level of the upper clouds: -The zonal speed is slightly increasing by absolute values from 90 on the equator to 105 m/s at latitudes —47 degrees; -The period of zonal rotation has the maximum at the equator (5 earth days). It has the minimum (3 days) at altitudes —50 degrees. After minimum periods are slightly increasing toward the South pole; -The meridional speed has a value 0 on the equator, and then it is linear increasing up to 10 m/s (by absolute value) at 50 degrees latitude. "-" denotes movement from the equator to the pole. -From 50 to 80 degrees the meridional speed is again decreasing by absolute value up to 0. IR (965+10 nm) day side images can be used for wind tracking. The obtained speed of the zonal wind in the low and middle latitudes are systematically less than the wind speed derived from the UV images. The average zonal speed obtained from IR day side images in the low and average latitudes is about 65-70 m/s. The given fact can be interpreted as observation of deeper layers of mesosphere in the IR range in comparison with UV. References [1] Markiewicz W. J. et al. (2007) Planet. Space Set V55(12). P.1701-1711. [2] Moissl R., et al. (2008) J. Geophys. Res. 2008. doi:10.1029/2008JE003117. V.113.

  13. Indirect Validation of Probe Speed Data on Arterial Corridors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eshragh, Sepideh; Young, Stanley E.; Sharifi, Elham

    This study aimed to estimate the accuracy of probe speed data on arterial corridors on the basis of roadway geometric attributes and functional classification. It was assumed that functional class (medium and low) along with other road characteristics (such as weighted average of the annual average daily traffic, average signal density, average access point density, and average speed) were available as correlation factors to estimate the accuracy of probe traffic data. This study tested these factors as predictors of the fidelity of probe traffic data by using the results of an extensive validation exercise. This study showed strong correlations betweenmore » these geometric attributes and the accuracy of probe data when they were assessed by using average absolute speed error. Linear models were regressed to existing data to estimate appropriate models for medium- and low-type arterial corridors. The proposed models for medium- and low-type arterials were validated further on the basis of the results of a slowdown analysis. These models can be used to predict the accuracy of probe data indirectly in medium and low types of arterial corridors.« less

  14. The Systolic Blood Pressure Difference Between Arms and Cardiovascular Disease in the Framingham Heart Study

    PubMed Central

    Weinberg, Ido; Gona, Philimon; O’Donnell, Christopher J.; Jaff, Michael R.; Murabito, Joanne M.

    2014-01-01

    Background An increased inter-arm systolic blood pressure difference is an easily determined physical examination finding. The relationship between inter-arm systolic blood pressure difference and risk of future cardiovascular disease is uncertain. We described the prevalence and risk factor correlates of inter-arm systolic blood pressure difference in the Framingham Heart Study (FHS) original and offspring cohorts and examined the association between inter-arm systolic blood pressure difference and incident cardiovascular disease and all-cause mortality. Methods An increased inter-arm systolic blood pressure difference was defined as ≥10mmHg using the average of initial and repeat blood pressure measurements obtained in both arms. Participants were followed through 2010 for incident cardiovascular disease events. Multivariable Cox proportional hazards regression analyses were performed to investigate the effect of inter-arm systolic blood pressure difference on incident cardiovascular disease. Results We examined 3,390 (56.3% female) participants aged 40 years and older, free of cardiovascular disease at baseline, mean age of 61.1 years, who attended a FHS examination between 1991 and 1994 (original cohort) and from 1995 to 1998 (offspring cohort). The mean absolute inter-arm systolic blood pressure difference was 4.6 mmHg (range 0 to 78). Increased inter-arm systolic blood pressure difference was present in 317 (9.4%) participants. The median follow-up time was 13.3 years, during which time 598 participants (17.6%) experienced a first cardiovascular event including 83 (26.2%) participants with inter-arm systolic blood pressure difference ≥10 mmHg. Compared to those with normal inter-arm systolic blood pressure difference, participants with an elevated inter-arm systolic blood pressure difference were older (63.0 years vs. 60.9 years), had a greater prevalence of diabetes mellitus (13.3% vs. 7.5%,), higher systolic blood pressure (136.3 mmHg vs. 129.3 mmHg), and a higher total cholesterol level (212.1 mg/dL vs. 206.5 mg/dL). Inter-arm systolic blood pressure difference was associated with a significantly increased hazard of incident cardiovascular events in the multivariable adjusted model (hazard ratio 1.38, 95% CI, 1.09 to 1.75). For each 1-standard deviation unit increase in absolute interarm systolic blood pressure difference, the hazard ratio for incident cardiovascular events was 1.07 (CI, 1.00 to 1.14) in the fully-adjusted model. There was no such association with mortality (hazard ratio 1.02, 95% CI 0.76 to 1.38). Conclusions In this community-based cohort, an inter-arm systolic blood pressure difference is common and associated with a significant increased risk for future cardiovascular events, even when the absolute difference in arm systolic blood pressure is modest. These findings support research to expand clinical use of this simple measurement. PMID:24287007

  15. Absolute quantification of regional cerebral glucose utilization in mice by 18F-FDG small animal PET scanning and 2-14C-DG autoradiography.

    PubMed

    Toyama, Hiroshi; Ichise, Masanori; Liow, Jeih-San; Modell, Kendra J; Vines, Douglass C; Esaki, Takanori; Cook, Michelle; Seidel, Jurgen; Sokoloff, Louis; Green, Michael V; Innis, Robert B

    2004-08-01

    The purpose of this study was to evaluate the feasibility of absolute quantification of regional cerebral glucose utilization (rCMR(glc)) in mice by use of (18)F-FDG and a small animal PET scanner. rCMR(glc) determined with (18)F-FDG PET was compared with values determined simultaneously by the autoradiographic 2-(14)C-DG method. In addition, we compared the rCMR(glc) values under isoflurane, ketamine and xylazine anesthesia, and awake states. Immediately after injection of (18)F-FDG and 2-(14)C-DG into mice, timed arterial samples were drawn over 45 min to determine the time courses of (18)F-FDG and 2-(14)C-DG. Animals were euthanized at 45 min and their brain was imaged with the PET scanner. The brains were then processed for 2-(14)C-DG autoradiography. Regions of interest were manually placed over cortical regions on corresponding coronal (18)F-FDG PET and 2-(14)C-DG autoradiographic images. rCMR(glc) values were calculated for both tracers by the autoradiographic 2-(14)C-DG method with modifications for the different rate and lumped constants for the 2 tracers. Average rCMR(glc) values in cerebral cortex with (18)F-FDG PET under normoglycemic conditions (isoflurane and awake) were generally lower (by 8.3%) but strongly correlated with those of 2-(14)C-DG (r(2) = 0.95). On the other hand, under hyperglycemic conditions (ketamine/xylazine) average cortical rCMR(glc) values with (18)F-FDG PET were higher (by 17.3%) than those with 2-(14)C-DG. Values for rCMR(glc) and uptake (percentage injected dose per gram [%ID/g]) with (18)F-FDG PET were significantly lower under both isoflurane and ketamine/xylazine anesthesia than in the awake mice. However, the reductions of rCMR(glc) were markedly greater under isoflurane (by 57%) than under ketamine and xylazine (by 19%), whereas more marked reductions of %ID/g were observed with ketamine/xylazine (by 54%) than with isoflurane (by 37%). These reverse differences between isoflurane and ketamine/xylazine may be due to competitive effect of (18)F-FDG and glucose uptake to the brain under hyperglycemia. We were able to obtain accurate absolute quantification of rCMR(glc) with mouse (18)F-FDG PET imaging as confirmed by concurrent use of the autoradiographic 2-(14)C-DG method. Underestimation of rCMR(glc) by (18)F-FDG in normoglycemic conditions may be due to partial-volume effects. Computation of rCMR(glc) from (18)F-FDG data in hyperglycemic animals may require, however, alternative rate and lumped constants for (18)F-FDG.

  16. Motor skills of toddlers with autism spectrum disorders.

    PubMed

    Lloyd, Meghann; MacDonald, Megan; Lord, Catherine

    2013-03-01

    With increased interest in the early diagnosis and treatment of children with autism spectrum disorders (ASD), more attention has been called to the motor skills of very young children with ASD. This study describes the gross and fine motor skills of a cross-sectional group of 162 children with ASD between the ages of 12 and 36 months, as well as a subset of 58 children followed longitudinally. Gross motor and fine motor age equivalent scores were obtained for all children. A 'motor difference' variable was calculated for each child's gross and fine motor skills by taking the absolute difference of the children's age equivalent motor score and their respective chronological age. In Study 1 (the cross-sectional analysis), ANCOVA (co-varied for nonverbal problem solving) revealed significant group differences in the gross motor and fine motor age difference variables. Post-hoc analysis revealed that gross motor and fine motor differences became significantly greater with each 6-month period of chronological age. In Study 2, 58 children were measured twice, an average of 12 months apart. Results indicate that the gross motor and fine motor difference scores significantly increased between the first and second measurements. The importance of addressing motor development in early intervention treatments is discussed.

  17. Impact of NO2 horizontal heterogeneity on tropospheric NO2 vertical columns retrieved from satellite, multi-axis differential optical absorption spectroscopy, and in situ measurements

    NASA Astrophysics Data System (ADS)

    Mendolia, D.; D'Souza, R. J. C.; Evans, G. J.; Brook, J.

    2013-01-01

    Tropospheric NO2 vertical column densities were retrieved for the first time in Toronto, Canada using three methods of differing spatial scales. Remotely-sensed NO2 vertical column densities, retrieved from multi-axis differential optical absorption spectroscopy and satellite remote sensing, were evaluated by comparison with in situ vertical column densities derived using a pair of chemiluminescence monitors situated 0.01 and 0.5 km above ground level. The chemiluminescence measurements were corrected for the influence of NOz, which reduced the NO2 concentrations at 0.01 and 0.5 km by 8 ± 1% and 12 ± 1%, respectively. The average absolute decrease in the chemiluminescence NO2 measurement as a result of this correction was less than 1 ppb. Good correlation was observed between the remotely sensed and in situ NO2 vertical column densities (Pearson R ranging from 0.68 to 0.79), but the in situ vertical column densities were 27% to 55% greater than the remotely-sensed columns. These results indicate that NO2 horizontal heterogeneity strongly impacted the magnitude of the remotely-sensed columns. The in situ columns reflected an urban environment with major traffic sources, while the remotely-sensed NO2 vertical column densities were representative of the region, which included spatial heterogeneity introduced by residential neighbourhoods and Lake Ontario. Despite the difference in absolute values, the reasonable correlation between the vertical column densities determined by three distinct methods increased confidence in the validity of the values provided by each of the methods.

  18. Brain size and encephalization in early to Mid-Pleistocene Homo.

    PubMed

    Rightmire, G Philip

    2004-06-01

    Important changes in the brain have occurred during the course of human evolution. Both absolute and relative size increases can be documented for species of Homo, culminating in the appearance of modern humans. One species that is particularly well-represented by fossil crania is Homo erectus. The mean capacity for 30 individuals is 973 cm(3). Within this group there is substantial variation, but brain size increases slightly in specimens from later time periods. Other Middle Pleistocene crania differ from those of Homo erectus. Characters of the facial skeleton, vault, and cranial base suggest that fossils from sites such as Arago Cave in France, the Sima de los Huesos in Spain, Bodo in Ethiopia, Broken Hill in Zambia, and perhaps Dali in China belong to the taxon Homo heidelbergensis. Ten of these mid-Quaternary hominins have brains averaging 1,206 cm(3) in volume, and many fall beyond the limits of size predicted for Homo erectus of equivalent age. When orbit height is used to construct an index of relative brain size, it is apparent that the (significant) increase in volume documented for the Middle Pleistocene individuals is not simply a consequence of larger body mass. Encephalization quotient values confirm this finding. These changes in absolute and relative brain size can be taken as further corroborative evidence for a speciation event, in which Homo erectus produced a daughter lineage. It is probable that Homo heidelbergensis originated in Africa or western Eurasia and then ranged widely across the Old World. Archaeological traces indicate that these populations differed in their technology and behavior from earlier hominins. Copyright 2003 Wiley-Liss, Inc.

  19. High resolution CCD spectra of stars in globular clusters. Part 2: Metals and CNO in M71

    NASA Technical Reports Server (NTRS)

    Leep, E. M.; Oke, J. B.; Wallerstein, G.

    1986-01-01

    Palomar coude CCD spectra of resolution 0.3 and 0.6 has been used to redetermine abundances in five stars of the relatively metal rich globular cluster M71. The (Fe/H) value is restricted to the limits of -0.6 to -1.0. The largest source of uncertainty is a systematic difference in f-values between those derived via the Holweger-Muller (1974) solar model and the Bell et al. (1976) solar model. If we use absolute f-values measured by the Oxford group (Blackwell et al. 1982) we find Fe/H to lie in the range of -0.6 to -0.75, i.e., as given by using the Bell et al. solar model. The relative abundances of the light elements, i.e., Na through Ca and probably including Ti show an average excess relative to iron of 0.4 dex. The effect of this difference on metal indices derived from broad- and narrow- band photometry is discussed. For three stars we find O/H = -0.6 using absolute f-values. For CN an analysis of individual rotational lines of the 2-0 band of the red system yields lines in the (C/H,N/H) plane that are consistent with either an original C/Fe = N/Fe = 0 or a modest increase in N relative to C due to CN burning and mixing. A search for C-13N was not successful and an uncertain lower limit of C-12/C-13 near 10 was obtained.

  20. Absolute Calibration of Si iRMs used for Measurements of Si Paleo-nutrient proxies

    NASA Astrophysics Data System (ADS)

    Vocke, R. D., Jr.; Rabb, S. A.

    2016-12-01

    Silicon isotope variations (reported as δ30Si and δ29Si, relative to NBS28) in silicic acid dissolved in ocean waters, in biogenic silica and in diatoms are extremely informative paleo-nutrient proxies. The resolution and comparability of such measurements depend on the quality of the isotopic Reference Materials (iRMs) defining the delta scale. We report new absolute Si isotopic measurements on the iRMs NBS28 (RM 8546 - Silica Sand), Diatomite, and Big Batch using the Avogadro measurement approach and comparing them with prior assessments of these iRMs. The Avogadro Si measurement technique was developed by the German Physikalish-Technische Bundesanstalt (PTB) to provide a precise and highly accurate method to measure absolute isotopic ratios in highly enriched 28Si (99.996%) material. These measurements are part of an international effort to redefine the kg and mole based on the Planck constant h and the Avogadro constant NA, respectively (Vocke et al., 2014 Metrologia 51, 361, Azuma et al., 2015 Metrologia 52 360). This approach produces absolute Si isotope ratio data with lower levels of uncertainty when compared to the traditional "Atomic Weights" method of absolute isotope ratio measurement calibration. This is illustrated in Fig. 1 where absolute Si isotopic measurements on SRM 990, separated by 40+ years of advances in instrumentation, are compared. The availability of this new technique does not say that absolute Si isotopic ratios are or ever will be better for normal Si isotopic measurements when seeking isotopic variations in nature, because they are not. However, by determining the absolute isotopic ratios of all the Si iRM scale artifacts, such iRMs become traceable to the metric system (SI); thereby automatically conferring on all the artifact-based δ30Si and δ29Si measurements traceability to the base SI unit, the mole. Such traceability should help reduce the potential of bias between different iRMs and facilitate the replacement of delta-scale artefacts when they run out. Fig. 1 Comparison of absolute isotopic measurements of SRM 990 using two radically different approaches to absolute calibration and mass bias corrections.

  1. Teaching the Double Layer.

    ERIC Educational Resources Information Center

    Bockris, J. O'M.

    1983-01-01

    Suggests various methods for teaching the double layer in electrochemistry courses. Topics addressed include measuring change in absolute potential difference (PD) at interphase, conventional electrode potential scale, analyzing absolute PD, metal-metal and overlap electron PDs, accumulation of material at interphase, thermodynamics of electrified…

  2. 40 CFR Appendix to Subpart Eee of... - Quality Assurance Procedures for Continuous Emissions Monitors Used for Hazardous Waste Combustors

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... capabilities. 2.2Relative Accuracy (RA). The absolute mean difference between the pollutant concentration... adjustment took place. 2.4Zero Drift (ZD). The difference in CEMS output readings at the zero pollutant level... Evaluation for CO, O2, and HC CEMS Carbon Monoxide (CO), Oxygen (O2), and Hydrocarbon (HC) CEMS. An Absolute...

  3. 40 CFR Appendix to Subpart Eee of... - Quality Assurance Procedures for Continuous Emissions Monitors Used for Hazardous Waste Combustors

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... capabilities. 2.2Relative Accuracy (RA). The absolute mean difference between the pollutant concentration... adjustment took place. 2.4Zero Drift (ZD). The difference in CEMS output readings at the zero pollutant level... Evaluation for CO, O2, and HC CEMS Carbon Monoxide (CO), Oxygen (O2), and Hydrocarbon (HC) CEMS. An Absolute...

  4. Absolute and Convective Instability of a Liquid Jet in Microgravity

    NASA Technical Reports Server (NTRS)

    Lin, Sung P.; Vihinen, I.; Honohan, A.; Hudman, Michael D.

    1996-01-01

    The transition from convective to absolute instability is observed in the 2.2 second drop tower of the NASA Lewis Research Center. In convective instability the disturbance grows spatially as it is convected downstream. In absolute instability the disturbance propagates both downstream and upstream, and manifests itself as an expanding sphere. The transition Reynolds numbers are determined for two different Weber numbers by use of Glycerin and a Silicone oil. Preliminary comparisons with theory are made.

  5. Comparison of different models for ground-level atmospheric turbulence strength (C(n)(2)) prediction with a new model according to local weather data for FSO applications.

    PubMed

    Arockia Bazil Raj, A; Arputha Vijaya Selvi, J; Durairaj, S

    2015-02-01

    Atmospheric parameters strongly affect the performance of free-space optical communication (FSOC) systems when the optical wave is propagating through the inhomogeneous turbulence transmission medium. Developing a model to get an accurate prediction of the atmospheric turbulence strength (C(n)(2)) according to meteorological parameters (weather data) becomes significant to understand the behavior of the FSOC channel during different seasons. The construction of a dedicated free-space optical link for the range of 0.5 km at an altitude of 15.25 m built at Thanjavur (Tamil Nadu) is described in this paper. The power level and beam centroid information of the received signal are measured continuously with weather data at the same time using an optoelectronic assembly and the developed weather station, respectively, and are recorded in a data-logging computer. Existing models that exhibit relatively fewer prediction errors are briefed and are selected for comparative analysis. Measured weather data (as input factors) and C(n)(2) (as a response factor) of size [177,147×4] are used for linear regression analysis and to design mathematical models more suitable in the test field. Along with the model formulation methodologies, we have presented the contributions of the input factors' individual and combined effects on the response surface and the coefficient of determination (R(2)) estimated using analysis of variance tools. An R(2) value of 98.93% is obtained using the new model, model equation V, from a confirmatory test conducted with a testing data set of size [2000×4]. In addition, the prediction accuracies of the selected and the new models are investigated during different seasons in a one-year period using the statistics of day, week-averaged, month-averaged, and seasonal-averaged diurnal Cn2 profiles, and are verified in terms of the sum of absolute error (SAE). A Cn2 prediction maximum average SAE of 2.3×10(-13)  m(-2/3) is achieved using the new model in a longer range of dynamic meteorological parameters during the different local seasons.

  6. [Prediction of schistosomiasis infection rates of population based on ARIMA-NARNN model].

    PubMed

    Ke-Wei, Wang; Yu, Wu; Jin-Ping, Li; Yu-Yu, Jiang

    2016-07-12

    To explore the effect of the autoregressive integrated moving average model-nonlinear auto-regressive neural network (ARIMA-NARNN) model on predicting schistosomiasis infection rates of population. The ARIMA model, NARNN model and ARIMA-NARNN model were established based on monthly schistosomiasis infection rates from January 2005 to February 2015 in Jiangsu Province, China. The fitting and prediction performances of the three models were compared. Compared to the ARIMA model and NARNN model, the mean square error (MSE), mean absolute error (MAE) and mean absolute percentage error (MAPE) of the ARIMA-NARNN model were the least with the values of 0.011 1, 0.090 0 and 0.282 4, respectively. The ARIMA-NARNN model could effectively fit and predict schistosomiasis infection rates of population, which might have a great application value for the prevention and control of schistosomiasis.

  7. Radiometric properties of the NS001 Thematic Mapper Simulator aircraft multispectral scanner

    NASA Technical Reports Server (NTRS)

    Markham, Brian L.; Ahmad, Suraiya P.

    1990-01-01

    Laboratory tests of the NS001 TM are described emphasizing absolute calibration to determine the radiometry of the simulator's reflective channels. In-flight calibration of the data is accomplished with the NS001 internal integrating-sphere source because instabilities in the source can limit the absolute calibration. The data from 1987-89 indicate uncertainties of up to 25 percent with an apparent average uncertainty of about 15 percent. Also identified are dark current drift and sensitivity changes along the scan line, random noise, and nonlinearity which contribute errors of 1-2 percent. Uncertainties similar to hysteresis are also noted especially in the 2.08-2.35-micron range which can reduce sensitivity and cause errors. The NS001 TM Simulator demonstrates a polarization sensitivity that can generate errors of up to about 10 percent depending on the wavelength.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, Bria M.; Brady, Samuel L., E-mail: samuel.brady@stjude.org; Kaufman, Robert A.

    Purpose: To investigate the correlation of size-specific dose estimate (SSDE) with absorbed organ dose, and to develop a simple methodology for estimating patient organ dose in a pediatric population (5–55 kg). Methods: Four physical anthropomorphic phantoms representing a range of pediatric body habitus were scanned with metal oxide semiconductor field effect transistor (MOSFET) dosimeters placed at 23 organ locations to determine absolute organ dose. Phantom absolute organ dose was divided by phantom SSDE to determine correlation between organ dose and SSDE. Organ dose correlation factors (CF{sub SSDE}{sup organ}) were then multiplied by patient-specific SSDE to estimate patient organ dose. Themore » CF{sub SSDE}{sup organ} were used to retrospectively estimate individual organ doses from 352 chest and 241 abdominopelvic pediatric CT examinations, where mean patient weight was 22 kg ± 15 (range 5–55 kg), and mean patient age was 6 yrs ± 5 (range 4 months to 23 yrs). Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm; thus, showing appropriate scalability of the phantoms across the entire pediatric population in this study. IndividualCF{sub SSDE}{sup organ} were determined for a total of 23 organs in the chest and abdominopelvic region across nine weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7–1.4) and abdominopelvic region (average 0.9; range 0.7–1.3) was near unity. For organ/tissue that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1–0.4) for both the chest and abdominopelvic regions, respectively. A means to estimate patient organ dose was demonstrated. Calculated patient organ dose, using patient SSDE and CF{sub SSDE}{sup organ}, was compared to previously published pediatric patient doses that accounted for patient size in their dose calculation, and was found to agree in the chest to better than an average of 5% (27.6/26.2) and in the abdominopelvic region to better than 2% (73.4/75.0). Conclusions: For organs fully covered within the scan volume, the average correlation of SSDE and organ absolute dose was found to be better than ±10%. In addition, this study provides a complete list of organ dose correlation factors (CF{sub SSDE}{sup organ}) for the chest and abdominopelvic regions, and describes a simple methodology to estimate individual pediatric patient organ dose based on patient SSDE.« less

  9. 237Np absolute delayed neutron yield measurements

    NASA Astrophysics Data System (ADS)

    Doré, D.; Ledoux, X.; Nolte, R.; Gagnon-Moisan, F.; Thulliez, L.; Litaize, O.; Roettger, S.; Serot, O.

    2017-09-01

    237Np absolute delayed neutron yields have been measured at different incident neutron energies from 1.5 to 16 MeV. The experiment was performed at the Physikalisch-Technische Bundesanstalt (PTB) facility where the Van de Graaff accelerator and the cyclotron CV28 delivered 9 different neutron energy beams using p+T, d+D and d+T reactions. The detection system is made up of twelve 3He tubes inserted into a polyethylene cylinder. In this paper, the experimental setup and the data analysis method are described. The evolution of the absolute DN yields as a function of the neutron incident beam energies are presented and compared to experimental data found in the literature and data from the libraries.

  10. Male Breast Cancer Incidence and Mortality Risk in the Japanese Atomic Bomb Survivors - Differences in Excess Relative and Absolute Risk from Female Breast Cancer.

    PubMed

    Little, Mark P; McElvenny, Damien M

    2017-02-01

    There are well-known associations of ionizing radiation with female breast cancer, and emerging evidence also for male breast cancer. In the United Kingdom, female breast cancer following occupational radiation exposure is among that set of cancers eligible for state compensation and consideration is currently being given to an extension to include male breast cancer. We compare radiation-associated excess relative and absolute risks of male and female breast cancers. Breast cancer incidence and mortality data in the Japanese atomic-bomb survivors were analyzed using relative and absolute risk models via Poisson regression. We observed significant (p ≤ 0.01) dose-related excess risk for male breast cancer incidence and mortality. For incidence and mortality data, there are elevations by factors of approximately 15 and 5, respectively, of relative risk for male compared with female breast cancer incidence, the former borderline significant (p = 0.050). In contrast, for incidence and mortality data, there are elevations by factors of approximately 20 and 10, respectively, of female absolute risk compared with male, both statistically significant (p < 0.001). There are no indications of differences between the sexes in age/time-since-exposure/age-at-exposure modifications to the relative or absolute excess risk. The probability of causation of male breast cancer following radiation exposure exceeds by at least a factor of 5 that of many other malignancies. There is evidence of much higher radiation-associated relative risk for male than for female breast cancer, although absolute excess risks for males are much less than for females. However, the small number of male cases and deaths suggests a degree of caution in interpretation of this finding. Citation: Little MP, McElvenny DM. 2017. Male breast cancer incidence and mortality risk in the Japanese atomic bomb survivors - differences in excess relative and absolute risk from female breast cancer. Environ Health Perspect 125:223-229; http://dx.doi.org/10.1289/EHP151.

  11. Missing value imputation in DNA microarrays based on conjugate gradient method.

    PubMed

    Dorri, Fatemeh; Azmi, Paeiz; Dorri, Faezeh

    2012-02-01

    Analysis of gene expression profiles needs a complete matrix of gene array values; consequently, imputation methods have been suggested. In this paper, an algorithm that is based on conjugate gradient (CG) method is proposed to estimate missing values. k-nearest neighbors of the missed entry are first selected based on absolute values of their Pearson correlation coefficient. Then a subset of genes among the k-nearest neighbors is labeled as the best similar ones. CG algorithm with this subset as its input is then used to estimate the missing values. Our proposed CG based algorithm (CGimpute) is evaluated on different data sets. The results are compared with sequential local least squares (SLLSimpute), Bayesian principle component analysis (BPCAimpute), local least squares imputation (LLSimpute), iterated local least squares imputation (ILLSimpute) and adaptive k-nearest neighbors imputation (KNNKimpute) methods. The average of normalized root mean squares error (NRMSE) and relative NRMSE in different data sets with various missing rates shows CGimpute outperforms other methods. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Evaluation of Piecewise Polynomial Equations for Two Types of Thermocouples

    PubMed Central

    Chen, Andrew; Chen, Chiachung

    2013-01-01

    Thermocouples are the most frequently used sensors for temperature measurement because of their wide applicability, long-term stability and high reliability. However, one of the major utilization problems is the linearization of the transfer relation between temperature and output voltage of thermocouples. The linear calibration equation and its modules could be improved by using regression analysis to help solve this problem. In this study, two types of thermocouple and five temperature ranges were selected to evaluate the fitting agreement of different-order polynomial equations. Two quantitative criteria, the average of the absolute error values |e|ave and the standard deviation of calibration equation estd, were used to evaluate the accuracy and precision of these calibrations equations. The optimal order of polynomial equations differed with the temperature range. The accuracy and precision of the calibration equation could be improved significantly with an adequate higher degree polynomial equation. The technique could be applied with hardware modules to serve as an intelligent sensor for temperature measurement. PMID:24351627

  13. On the absolute calibration of SO2 cameras

    USGS Publications Warehouse

    Lübcke, Peter; Bobrowski, Nicole; Illing, Sebastian; Kern, Christoph; Alvarez Nieves, Jose Manuel; Vogel, Leif; Zielcke, Johannes; Delgados Granados, Hugo; Platt, Ulrich

    2013-01-01

    This work investigates the uncertainty of results gained through the two commonly used, but quite different, calibration methods (DOAS and calibration cells). Measurements with three different instruments, an SO2 camera, a NFOVDOAS system and an Imaging DOAS (I-DOAS), are presented. We compare the calibration-cell approach with the calibration from the NFOV-DOAS system. The respective results are compared with measurements from an I-DOAS to verify the calibration curve over the spatial extent of the image. The results show that calibration cells, while working fine in some cases, can lead to an overestimation of the SO2 CD by up to 60% compared with CDs from the DOAS measurements. Besides these errors of calibration, radiative transfer effects (e.g. light dilution, multiple scattering) can significantly influence the results of both instrument types. The measurements presented in this work were taken at Popocatepetl, Mexico, between 1 March 2011 and 4 March 2011. Average SO2 emission rates between 4.00 and 14.34 kg s−1 were observed.

  14. Toward relaxed eddy accumulation measurements of sediment-water exchange in aquatic ecosystems

    NASA Astrophysics Data System (ADS)

    Lemaire, Bruno J.; Noss, Christian; Lorke, Andreas

    2017-09-01

    Solute transport across the sediment-water interface has major implications for water quality and biogeochemical cycling in aquatic ecosystems. Existing measurement techniques, however, are not capable of resolving sediment-water fluxes of most constituents under in situ flow conditions. We investigated whether relaxed eddy accumulation (REA), a micrometeorological technique with conditional sampling of turbulent updrafts and downdrafts, can be adapted to the aquatic environment. We simulated REA fluxes by reanalyzing eddy covariance measurements from a riverine lake. We found that the empirical coefficient that relates mass fluxes to the concentration difference between both REA samples is invariant with scalar and flow and responds as predicted by a joint Gaussian distribution of linearly correlated variables. Simulated REA fluxes differed on average by around 30% from eddy covariance fluxes (mean absolute error). Assessment of the lower quantification limit suggests that REA can potentially be applied for measuring benthic fluxes of a new range of constituents that cannot be assessed by standard eddy covariance methods.

  15. Near-lossless multichannel EEG compression based on matrix and tensor decompositions.

    PubMed

    Dauwels, Justin; Srinivasan, K; Reddy, M Ramasubba; Cichocki, Andrzej

    2013-05-01

    A novel near-lossless compression algorithm for multichannel electroencephalogram (MC-EEG) is proposed based on matrix/tensor decomposition models. MC-EEG is represented in suitable multiway (multidimensional) forms to efficiently exploit temporal and spatial correlations simultaneously. Several matrix/tensor decomposition models are analyzed in view of efficient decorrelation of the multiway forms of MC-EEG. A compression algorithm is built based on the principle of “lossy plus residual coding,” consisting of a matrix/tensor decomposition-based coder in the lossy layer followed by arithmetic coding in the residual layer. This approach guarantees a specifiable maximum absolute error between original and reconstructed signals. The compression algorithm is applied to three different scalp EEG datasets and an intracranial EEG dataset, each with different sampling rate and resolution. The proposed algorithm achieves attractive compression ratios compared to compressing individual channels separately. For similar compression ratios, the proposed algorithm achieves nearly fivefold lower average error compared to a similar wavelet-based volumetric MC-EEG compression algorithm.

  16. Intermediate Valence Tuning and Seebeck Coefficient Optimization in Yb-based Low-Temperature Thermoelectric Materials

    NASA Astrophysics Data System (ADS)

    Lehr, Gloria; Morelli, Donald; Jin, Hyungyu; Heremans, Joseph

    2014-03-01

    Several Yb-based intermediate valence compounds have unique thermoelectric properties at low temperatures. These materials are interesting to study for niche applications such as cryogenic Peltier cooling of infrared sensors on satellites. Elements of different sizes, which form isostructural compounds, are used to form solid solutions creating a chemical pressure (smaller atoms - Sc) or relaxation (larger atoms - La) to alter the volume of the unit cell and thereby manipulate the average Yb valence. Magnetic susceptibility measurements show a strong correlation between the Seebeck coefficient and the ratio of trivalent to divalent Yb in these compounds. Two different Yb-based solid solution systems, Yb1-xScxAl2 and Yb1-xLaxCu2Si2, demonstrate that the concentration of Yb can be used to tune both the magnitude of the Seebeck coefficient as well as the temperature at which its absolute maximum occurs. This work is supported by Michigan State University and AFOSR-MURI ``Cryogenic Peltier Cooling'' Contract #FA9550-10-1-0533.

  17. Colors and Shapes of the Irregular Planetary Satellites

    NASA Astrophysics Data System (ADS)

    Graykowski, Ariel; Jewitt, David

    2018-04-01

    It is widely recognized that the irregular satellites of the giant planets were captured from initially heliocentric orbits. However, the mechanism of capture and the source region from which they were captured both remain unknown. We present an optical color survey of 43 irregular satellites of the outer planets conducted using the LRIS camera on the 10 m telescope at the Keck Observatory in Hawaii. The measured colors are compared to other planetary bodies in search for similarities and differences that may reflect upon the origin of the satellites. We find that ultrared matter (with color index B–R ≥ 1.6), while abundant in the Kuiper Belt and Centaur populations, is depleted from the irregular satellites. We also use repeated determinations of the absolute magnitudes to make a statistical estimate of the average shape of the irregular satellites. The data provide no evidence that the satellites and the main-belt asteroids are differently shaped, consistent with collisions as the major agent shaping both.

  18. Comparison of evidence on harms of medical interventions in randomized and nonrandomized studies

    PubMed Central

    Papanikolaou, Panagiotis N.; Christidi, Georgia D.; Ioannidis, John P.A.

    2006-01-01

    Background Information on major harms of medical interventions comes primarily from epidemiologic studies performed after licensing and marketing. Comparison with data from large-scale randomized trials is occasionally feasible. We compared evidence from randomized trials with that from epidemiologic studies to determine whether they give different estimates of risk for important harms of medical interventions. Methods We targeted well-defined, specific harms of various medical interventions for which data were already available from large-scale randomized trials (> 4000 subjects). Nonrandomized studies involving at least 4000 subjects addressing these same harms were retrieved through a search of MEDLINE. We compared the relative risks and absolute risk differences for specific harms in the randomized and nonrandomized studies. Results Eligible nonrandomized studies were found for 15 harms for which data were available from randomized trials addressing the same harms. Comparisons of relative risks between the study types were feasible for 13 of the 15 topics, and of absolute risk differences for 8 topics. The estimated increase in relative risk differed more than 2-fold between the randomized and nonrandomized studies for 7 (54%) of the 13 topics; the estimated increase in absolute risk differed more than 2-fold for 5 (62%) of the 8 topics. There was no clear predilection for randomized or nonrandomized studies to estimate greater relative risks, but usually (75% [6/8]) the randomized trials estimated larger absolute excess risks of harm than the nonrandomized studies did. Interpretation Nonrandomized studies are often conservative in estimating absolute risks of harms. It would be useful to compare and scrutinize the evidence on harms obtained from both randomized and nonrandomized studies. PMID:16505459

  19. On the transport of emulsions in porous media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cortis, Andrea; Ghezzehei, Teamrat A.

    2007-06-27

    Emulsions appear in many subsurface applications includingbioremediation, surfactant-enhanced remediation, and enhancedoil-recovery. Modeling emulsion transport in porous media is particularlychallenging because the rheological and physical properties of emulsionsare different from averages of the components. Current modelingapproaches are based on filtration theories, which are not suited toadequately address the pore-scale permeability fluctuations and reductionof absolute permeability that are often encountered during emulsiontransport. In this communication, we introduce a continuous time randomwalk based alternative approach that captures these unique features ofemulsion transport. Calculations based on the proposed approach resultedin excellent match with experimental observations of emulsionbreakthrough from the literature. Specifically, the new approachmore » explainsthe slow late-time tailing behavior that could not be fitted using thestandard approach. The theory presented in this paper also provides animportant stepping stone toward a generalizedself-consistent modeling ofmultiphase flow.« less

  20. Mathematical tool from corn stover TGA to determine its composition.

    PubMed

    Freda, Cesare; Zimbardi, Francesco; Nanna, Francesco; Viola, Egidio

    2012-08-01

    Corn stover was treated by steam explosion process at four different temperatures. A fraction of the four exploded matters was extracted by water. The eight samples (four from steam explosion and four from water extraction of exploded matters) were analysed by wet chemical way to quantify the amount of cellulose, hemicellulose and lignin. Thermogravimetric analysis in air atmosphere was executed on the eight samples. A mathematical tool was developed, using TGA data, to determine the composition of corn stover in terms of cellulose, hemicellulose and lignin. It uses the biomass degradation temperature as multiple linear function of the cellulose, hemicellulose and lignin content of the biomass with interactive terms. The mathematical tool predicted cellulose, hemicellulose and lignin contents with average absolute errors of 1.69, 5.59 and 0.74 %, respectively, compared to the wet chemical method.

Top