Kato, Haruhisa; Nakamura, Ayako; Takahashi, Kayori; Kinugasa, Shinichi
2012-01-01
Accurate determination of the intensity-average diameter of polystyrene latex (PS-latex) by dynamic light scattering (DLS) was carried out through extrapolation of both the concentration of PS-latex and the observed scattering angle. Intensity-average diameter and size distribution were reliably determined by asymmetric flow field flow fractionation (AFFFF) using multi-angle light scattering (MALS) with consideration of band broadening in AFFFF separation. The intensity-average diameter determined by DLS and AFFFF-MALS agreed well within the estimated uncertainties, although the size distribution of PS-latex determined by DLS was less reliable in comparison with that determined by AFFFF-MALS. PMID:28348293
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bostani, Maryam, E-mail: mbostani@mednet.ucla.edu; McMillan, Kyle; Lu, Peiyun
2015-02-15
Purpose: Task Group 204 introduced effective diameter (ED) as the patient size metric used to correlate size-specific-dose-estimates. However, this size metric fails to account for patient attenuation properties and has been suggested to be replaced by an attenuation-based size metric, water equivalent diameter (D{sub W}). The purpose of this study is to investigate different size metrics, effective diameter, and water equivalent diameter, in combination with regional descriptions of scanner output to establish the most appropriate size metric to be used as a predictor for organ dose in tube current modulated CT exams. Methods: 101 thoracic and 82 abdomen/pelvis scans frommore » clinically indicated CT exams were collected retrospectively from a multidetector row CT (Sensation 64, Siemens Healthcare) with Institutional Review Board approval to generate voxelized patient models. Fully irradiated organs (lung and breasts in thoracic scans and liver, kidneys, and spleen in abdominal scans) were segmented and used as tally regions in Monte Carlo simulations for reporting organ dose. Along with image data, raw projection data were collected to obtain tube current information for simulating tube current modulation scans using Monte Carlo methods. Additionally, previously described patient size metrics [ED, D{sub W}, and approximated water equivalent diameter (D{sub Wa})] were calculated for each patient and reported in three different ways: a single value averaged over the entire scan, a single value averaged over the region of interest, and a single value from a location in the middle of the scan volume. Organ doses were normalized by an appropriate mAs weighted CTDI{sub vol} to reflect regional variation of tube current. Linear regression analysis was used to evaluate the correlations between normalized organ doses and each size metric. Results: For the abdominal organs, the correlations between normalized organ dose and size metric were overall slightly higher for all three differently (global, regional, and middle slice) reported D{sub W} and D{sub Wa} than they were for ED, but the differences were not statistically significant. However, for lung dose, computed correlations using water equivalent diameter calculated in the middle of the image data (D{sub W,middle}) and averaged over the low attenuating region of lung (D{sub W,regional}) were statistically significantly higher than correlations of normalized lung dose with ED. Conclusions: To conclude, effective diameter and water equivalent diameter are very similar in abdominal regions; however, their difference becomes noticeable in lungs. Water equivalent diameter, specifically reported as a regional average and middle of scan volume, was shown to be better predictors of lung dose. Therefore, an attenuation-based size metric (water equivalent diameter) is recommended because it is more robust across different anatomic regions. Additionally, it was observed that the regional size metric reported as a single value averaged over a region of interest and the size metric calculated from a single slice/image chosen from the middle of the scan volume are highly correlated for these specific patient models and scan types.« less
Diameter Growth of Southern Bottomland Hardwoods
Henry Bull
1945-01-01
There is very little published information on average rates of diameter growth of southern bottomland hardwoods. Probably the best information of this kind is given by Winters, Putnam, and Eldredge,2 who summarize forest survey data on average rates of diameter growth for 4 size classes and 20 species or species groups (including pine and cyress), and for all species...
Measurement and interpretation of skin prick test results.
van der Valk, J P M; Gerth van Wijk, R; Hoorn, E; Groenendijk, L; Groenendijk, I M; de Jong, N W
2015-01-01
There are several methods to read skin prick test results in type-I allergy testing. A commonly used method is to characterize the wheal size by its 'average diameter'. A more accurate method is to scan the area of the wheal to calculate the actual size. In both methods, skin prick test (SPT) results can be corrected for histamine-sensitivity of the skin by dividing the results of the allergic reaction by the histamine control. The objectives of this study are to compare different techniques of quantifying SPT results, to determine a cut-off value for a positive SPT for histamine equivalent prick -index (HEP) area, and to study the accuracy of predicting cashew nut reactions in double-blind placebo-controlled food challenge (DBPCFC) tests with the different SPT methods. Data of 172 children with cashew nut sensitisation were used for the analysis. All patients underwent a DBPCFC with cashew nut. Per patient, the average diameter and scanned area of the wheal size were recorded. In addition, the same data for the histamine-induced wheal were collected for each patient. The accuracy in predicting the outcome of the DBPCFC using four different SPT readings (i.e. average diameter, area, HEP-index diameter, HEP-index area) were compared in a Receiver-Operating Characteristic (ROC) plot. Characterizing the wheal size by the average diameter method is inaccurate compared to scanning method. A wheal average diameter of 3 mm is generally considered as a positive SPT cut-off value and an equivalent HEP-index area cut-off value of 0.4 was calculated. The four SPT methods yielded a comparable area under the curve (AUC) of 0.84, 0.85, 0.83 and 0.83, respectively. The four methods showed comparable accuracy in predicting cashew nut reactions in a DBPCFC. The 'scanned area method' is theoretically more accurate in determining the wheal area than the 'average diameter method' and is recommended in academic research. A HEP-index area of 0.4 is determined as cut-off value for a positive SPT. However, in clinical practice, the 'average diameter method' is also useful, because this method provides similar accuracy in predicting cashew nut allergic reactions in the DBPCFC. Trial number NTR3572.
Ding, Yongbo; Kan, Jianquan
2017-12-01
Chemically modified starch (RS4) nanoparticles were synthesized through homogenization and water-in-oil mini-emulsion cross-linking. Homogenization was optimized with regard to z-average diameter by using a three-factor-three-level Box-Behnken design. Homogenization pressure (X 1 ), oil/water ratio (X 2 ), and surfactant (X 3 ) were selected as independent variables, whereas z-average diameter was considered as a dependent variable. The following optimum preparation conditions were obtained to achieve the minimum average size of these nanoparticles: 50 MPa homogenization pressure, 10:1 oil/water ratio, and 2 g surfactant amount, when the predicted z-average diameter was 303.6 nm. The physicochemical properties of these nanoparticles were also determined. Dynamic light scattering experiments revealed that RS4 nanoparticles measuring a PdI of 0.380 and an average size of approximately 300 nm, which was very close to the predicted z-average diameter (303.6 nm). The absolute value of zeta potential of RS4 nanoparticles (39.7 mV) was higher than RS4 (32.4 mV), with strengthened swelling power. X-ray diffraction results revealed that homogenization induced a disruption in crystalline structure of RS4 nanoparticles led to amorphous or low-crystallinity. Results of stability analysis showed that RS4 nanosuspensions (particle size) had good stability at 30 °C over 24 h.
Sell, Scott; Barnes, Catherine; Simpson, David; Bowlin, Gary
2008-04-01
The purpose of this study was to construct a flowmeter that could accurately measure the hydraulic permeability of electrospun fibrinogen scaffolds, providing insight into the transport properties of electrospun scaffolds while making the measurement of their topographical features (fiber diameter and pore size) more accurate. Three different concentrations of fibrinogen were used (100, 120, and 150 mg/mL) to create scaffolds with three different fiber diameters and pore sizes. The fiber diameters and pore sizes of the electrospun scaffolds were first analyzed with scanning electron microscopy and image analysis software. The permeability of each scaffold was measured with the flowmeter and used to calculate permeability-based fiber diameters and pore sizes, which were compared to values obtained through image analysis. Permeability measurement revealed scaffold permeability to increase with fibrinogen concentration, much like average fiber diameter and pore size. Comparison between the two measurement methods demonstrated the efficacy of the flowmeter as a way to measure scaffold features. Copyright 2007 Wiley Periodicals, Inc.
Correlation between extraocular muscle size and motility restriction in thyroid eye disease.
Dagi, Lora R; Zoumalan, Christopher I; Konrad, Hindola; Trokel, Stephen L; Kazim, Michael
2011-01-01
Evaluate the relationship between extraocular muscle (EOM) size, measured by computed tomography, and ocular motility in thyroid eye disease (TED). This case series is based on a retrospective review of the records of 54 patients (108 orbits) with TED. Main outcome measures included EOM size and degree of motility restriction. The average diameter of each rectus muscle was compared with published norms. Four subpopulations based on Age (< 40 or ≥ 40 years) and State of thyroid eye disease (active or stable) were studied. Versions were measured by the corneal light reflex method. The trend of muscle diameter versus motility restriction was evaluated. The average EOM diameter was greater than the norm in the study cohort and 4 subpopulations. The average diameter was largest in the Older and Active TED subpopulations. The inferior rectus and medial rectus were most frequently restricted in the study cohort and 4 subpopulations. The medial rectus had the strongest trend between increasing diameter and motility restriction, followed by the inferior rectus and the superior muscle group (comprised of the superior rectus and levator palpebrae superioris). However, there was a general lack of strong correlation between the diameter of the rectus muscles and their respective motility, especially in the Younger subpopulation. EOM diameters are larger and have more restricted motility in the Older and Active TED subpopulations. Contrary to prior publications, the correlation between EOM diameters and motility was weak, especially in the Younger subpopulation. These findings suggest that the pathophysiology of EOM enlargement is different based upon the age of the patient and the activity of the orbitopathy.
Orthopedic stretcher with average-sized person can pass through 18-inch opening
NASA Technical Reports Server (NTRS)
Lothschuetz, F. X.
1966-01-01
Modified Robinson stretcher for vertical lifting and carrying, will pass through an opening 18 inches in diameter, while containing a person of average height and weight. A subject 6 feet tall and weighing 200 pounds was lowered and raised out of an 18 inch diameter opening in a tank to test the stretcher.
Influence of cervical preflaring on apical file size determination.
Pecora, J D; Capelli, A; Guerisoli, D M Z; Spanó, J C E; Estrela, C
2005-07-01
To investigate the influence of cervical preflaring with different instruments (Gates-Glidden drills, Quantec Flare series instruments and LA Axxess burs) on the first file that binds at working length (WL) in maxillary central incisors. Forty human maxillary central incisors with complete root formation were used. After standard access cavities, a size 06 K-file was inserted into each canal until the apical foramen was reached. The WL was set 1 mm short of the apical foramen. Group 1 received the initial apical instrument without previous preflaring of the cervical and middle thirds of the root canal. Group 2 had the cervical and middle portion of the root canals enlarged with Gates-Glidden drills sizes 90, 110 and 130. Group 3 had the cervical and middle thirds of the root canals enlarged with nickel-titanium Quantec Flare series instruments. Titanium-nitrite treated, stainless steel LA Axxess burs were used for preflaring the cervical and middle portions of root canals from group 4. Each canal was sized using manual K-files, starting with size 08 files with passive movements until the WL was reached. File sizes were increased until a binding sensation was felt at the WL, and the instrument size was recorded for each tooth. The apical region was then observed under a stereoscopic magnifier, images were recorded digitally and the differences between root canal and maximum file diameters were evaluated for each sample. Significant differences were found between experimental groups regarding anatomical diameter at the WL and the first file to bind in the canal (P < 0.01, 95% confidence interval). The major discrepancy was found when no preflaring was performed (0.151 mm average). The LA Axxess burs produced the smallest differences between anatomical diameter and first file to bind (0.016 mm average). Gates-Glidden drills and Flare instruments were ranked in an intermediary position, with no statistically significant differences between them (0.093 mm average). The instrument binding technique for determining anatomical diameter at WL is not precise. Preflaring of the cervical and middle thirds of the root canal improved anatomical diameter determination; the instrument used for preflaring played a major role in determining the anatomical diameter at the WL. Canals preflared with LA Axxess burs created a more accurate relationship between file size and anatomical diameter.
The densest loblolly pine stand and its silvicultural implications
Boris Zeide; John Stephens
2010-01-01
Estimation of stand density index has been based on the assumption that the only cause of mortality in fully stocked stands is diameter growth. For example, when average diameter increases by 1 percent, a fixed proportion (1.6 percent) of trees must die, regardless of age, average tree size, and other factors. This balance between growth and mortality entails the...
NASA Astrophysics Data System (ADS)
Hernández-Pinero, Jorge Luis; Terrón-Rebolledo, Manuel; Foroughbakhch, Rahim; Moreno-Limón, Sergio; Melendrez, M. F.; Solís-Pomar, Francisco; Pérez-Tijerina, Eduardo
2016-11-01
Mixing aqueous silver solutions with aqueous leaf aromatic plant extracts from basil, mint, marjoram and peppermint resulted in the synthesis of quasi-spherical silver nanoparticles in a range of size between 2 and 80 nm in diameter as analyzed by analytical high-resolution electron microscopy. The average size could be controlled by applying heat to the initial reaction system at different rates of heating, and by the specific botanical species employed for the reaction. Increasing the rate of heating resulted in a statistically significant decrease in the size of the nanoparticles produced, regardless of the species employed. This fact was more evident in the case of marjoram, which decreased the average diameter from 27 nm at a slow rate of heating to 8 nm at a high rate of heating. With regard to the species, minimum sizes of <10 nm were obtained with basil and peppermint, while marjoram and mint yielded an average size between 10 and 25 nm. The results indicate that aromatic plant extracts can be used to achieve the controlled synthesis of metal nanoparticles.
Influence of hydrothermal synthesis parameters on the properties of hydroxyapatite nanoparticles.
Kuśnieruk, Sylwia; Wojnarowicz, Jacek; Chodara, Agnieszka; Chudoba, Tadeusz; Gierlotka, Stanislaw; Lojkowski, Witold
2016-01-01
Hydroxyapatite (HAp) nanoparticles of tunable diameter were obtained by the precipitation method at room temperature and by microwave hydrothermal synthesis (MHS). The following parameters of the obtained nanostructured HAp were determined: pycnometric density, specific surface area, phase purity, lattice parameters, particle size, particle size distribution, water content, and structure. HAp nanoparticle morphology and structure were determined using scanning electron microscopy (SEM) and transmission electron microscopy (TEM). X-ray diffraction measurements confirmed crystalline HAp was synthesized, which was pure in terms of phase. It was shown that by changing the synthesis parameters, the diameter of HAp nanoparticles could be controlled. The average diameter of the HAp nanoparticles was determined by Scherrer's equation via the Nanopowder XRD Processor Demo web application, which interprets the results of specific surface area and TEM measurements using the dark-field technique. The obtained nanoparticles with average particle diameter ranging from 8-39 nm were characterized by having homogeneous morphology with a needle shape and a narrow particle size distribution. Strong similarities were found when comparing the properties of some types of nanostructured hydroxyapatite with natural occurring apatite found in animal bones and teeth.
Braun, Birgit; Dorgan, John R; Chandler, John P
2008-04-01
Mathematical treatment of light scattering within the Rayleigh-Gans-Debye limit for spheroids with polydispersity in both length and diameter is developed and experimentally tested using cellulosic nanowhiskers (CNW). Polydispersity indices are obtained by fitting the theoretical formfactor to experimental data. Good agreement is achieved using a polydispersity of 2.3 for the length, independent of the type of acid used. Diameter polydispersities are 2.1 and 3.0 for sulfuric and hydrochloric acids, respectively. These polydispersities allow the determination of average dimensions from the z-average mean-square radius (z) and the weight-average molecular weight (M w) easily obtained from Berry plots. For cotton linter hydrolyzed by hydrochloric acid, the average length and diameter are 244 and 22 nm. This compares to average length and diameter of 272 and 13 nm for sulfuric acid. This study establishes a new light-scattering methodology as a quick and robust tool for size characterization of polydisperse spheroidal nanoparticles.
Yu, Bi-yun; Zhang, Wen-hui; He, Ting; You, Jian-jian; Li, Gang
2014-12-01
Typical sampling method was conducted to survey the effects of forest gap size on branch architecture, leaf characteristics and their vertical distribution of Quercus variablis seedlings from different size gaps in natural secondary Q. variablis thinning forest, on the south slope of Qinling Mountains. The results showed that gap size significantly affected the diameter, crown area of Q. variablis seedlings. The gap size positively correlated with diameter and negatively correlated with crown area, while it had no significant impact on seedling height, crown length and crown rates. The overall bifurcation ratio, stepwise bifurcation ratio, and ratio of branch diameter followed as large gap > middle gap > small gap > understory. The vertical distribution of first-order branches under different size gaps mainly concentrated at the middle and upper part of trunk, larger diameter first-order branches were mainly distributed at the lower part of trunk, and the angle of first-order branch increased at first and then declined with the increasing seedling height. With the increasing forest gap size, the leaf length, leaf width and average leaf area of seedlings all gradually declined, while the average leaf number per plant and relative total leaf number increased, the leaf length-width ratio kept stable, the relative leaf number was mainly distributed at the middle and upper parts of trunk, the changes of leaf area index was consistent with the change of the relative total number of leaves. There was no significant difference between the diameters of middle gap and large gap seedlings, but the diameter of middle gap seedlings was higher than that of large gap, suggesting the middle gap would benefit the seedlings regeneration and high-quality timber cultivation. To promote the regeneration of Q. variabilis seedlings, and to cultivate high-quality timber, appropriate thinning should be taken to increase the number of middle gaps in the management of Q. variabilis forest.
Error rate of automated calculation for wound surface area using a digital photography.
Yang, S; Park, J; Lee, H; Lee, J B; Lee, B U; Oh, B H
2018-02-01
Although measuring would size using digital photography is a quick and simple method to evaluate the skin wound, the possible compatibility of it has not been fully validated. To investigate the error rate of our newly developed wound surface area calculation using digital photography. Using a smartphone and a digital single lens reflex (DSLR) camera, four photographs of various sized wounds (diameter: 0.5-3.5 cm) were taken from the facial skin model in company with color patches. The quantitative values of wound areas were automatically calculated. The relative error (RE) of this method with regard to wound sizes and types of camera was analyzed. RE of individual calculated area was from 0.0329% (DSLR, diameter 1.0 cm) to 23.7166% (smartphone, diameter 2.0 cm). In spite of the correction of lens curvature, smartphone has significantly higher error rate than DSLR camera (3.9431±2.9772 vs 8.1303±4.8236). However, in cases of wound diameter below than 3 cm, REs of average values of four photographs were below than 5%. In addition, there was no difference in the average value of wound area taken by smartphone and DSLR camera in those cases. For the follow-up of small skin defect (diameter: <3 cm), our newly developed automated wound area calculation method is able to be applied to the plenty of photographs, and the average values of them are a relatively useful index of wound healing with acceptable error rate. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Ahrens, E.H.
1998-07-07
An ultrafine cementitious grout is described having a particle size 90% of which are less than 6 {micro}m in diameter and an average size of about 2.5 {micro}m or less, and preferably 90% of which are less than 5 {micro}m in diameter and an average size of about 2 {micro}m or less containing Portland cement, pumice as a pozzolanic material and superplasticizer in the amounts of about 40 wt. % to about 50 wt. % Portland cement; from about 50 wt. % to about 60 wt. % pumice containing at least 60% amorphous silicon dioxide; and from 0.1 wt. % to about 1.5 wt. % superplasticizer. The grout is mixed with water in the W/CM ratio of about 0.4--0.6/1. The grout has very high strength and very low permeability with good workability. The ultrafine particle sizes allow for sealing of microfractures below 10 {micro}m in width. 4 figs.
Ahrens, Ernst H.
1998-01-01
An ultrafine cementitious grout having a particle size 90% of which are less than 6 .mu.m in diameter and an average size of about 2.5 .mu.m or less, and preferably 90% of which are less than 5 .mu.m in diameter and an average size of about 2 .mu.m or less containing Portland cement, pumice as a pozzolanic material and superplasticizer in the amounts of about 40 wt. % to about 50 wt. % Portland cement; from about 50 wt. % to about 60 wt. % pumice containing at least 60% amorphous silicon dioxide; and from 0.1 wt. % to about 1.5 wt. % superplasticizer. The grout is mixed with water in the W/CM ratio of about 0.4-0.6/1. The grout has very high strength and very low permeability with good workability. The ultrafine particle sizes allow for sealing of microfractures below 10 .mu.m in width.
Size quantization patterns in self-assembled InAs/GaAs quantum dots
NASA Astrophysics Data System (ADS)
Colocci, M.; Bogani, F.; Carraresi, L.; Mattolini, R.; Bosacchi, A.; Franchi, S.; Frigeri, P.; Taddei, S.; Rosa-Clot, M.
1997-07-01
Molecular beam epitaxy has been used for growing self-assembled InAs quantum dots. A continuous variation of the InAs average coverage across the sample has been obtained by properly aligning the (001) GaAs substrate with respect to the molecular beam. Excitation of a large number of dots (laser spot diameter ≈ 100 μm) results in structured photoluminescence spectra; a clear quantization of the dot sizes is deduced from the distinct luminescence bands separated in energy by an average spacing of 20-30 meV. We ascribe the individual bands of the photoluminescence spectrum after low excitation to families of dots with roughly the same diameter and heights differing by one monolayer.
Measurement of Average Aggregate Density by Sedimentation and Brownian Motion Analysis.
Cavicchi, Richard E; King, Jason; Ripple, Dean C
2018-05-01
The spatially averaged density of protein aggregates is an important parameter that can be used to relate size distributions measured by orthogonal methods, to characterize protein particles, and perhaps to estimate the amount of protein in aggregate form in a sample. We obtained a series of images of protein aggregates exhibiting Brownian diffusion while settling under the influence of gravity in a sealed capillary. The aggregates were formed by stir-stressing a monoclonal antibody (NISTmAb). Image processing yielded particle tracks, which were then examined to determine settling velocity and hydrodynamic diameter down to 1 μm based on mean square displacement analysis. Measurements on polystyrene calibration microspheres ranging in size from 1 to 5 μm showed that the mean square displacement diameter had improved accuracy over the diameter derived from imaged particle area, suggesting a future method for correcting size distributions based on imaging. Stokes' law was used to estimate the density of each particle. It was found that the aggregates were highly porous with density decreasing from 1.080 to 1.028 g/cm 3 as the size increased from 1.37 to 4.9 μm. Published by Elsevier Inc.
Lewińska, Dorota; Rosiński, Stefan; Weryński, Andrzej
2004-02-01
In the medical applications of microencapsulation of living cells there are strict requirements concerning the high size uniformity and the optimal diameter, the latter dependent on the kind of therapeutic application, of manufactured gel beads. The possibility of manufacturing small size gel bead samples (diameter 300 microm and below) with a low size dispersion (less than 10%), using an impulsed voltage droplet generator, was examined in this work. The main topic was the investigation of the influence of values of electric parameters (voltage U, impulse time tau and impulse frequency f) on the quality of obtained droplets. It was concluded that, owing to the implementation of the impulse mode and regulation of tau and f values, it is possible to work in a controlled manner in the jet flow regime (U> critical voltage UC). It is also possible to obtain uniform bead samples with the average diameter, deff, significantly lower than the nozzle inner diameter dI (bead diameters 0.12-0.25 mm by dI equal to 0.3 mm, size dispersion 5-7%). Alterations of the physical parameters of the process (polymer solution physico-chemical properties, flow rate, distance between nozzle and gellifying bath) enable one to manufacture uniform gel beads in the wide range of diameters using a single nozzle.
NASA Technical Reports Server (NTRS)
Gao, Wenyuan; Wiederhold, Michael; Hejl, Robert
1997-01-01
The development of the statocyst of the freshwater snail Biomphalaria glabrata has been examined from embryo to adult. Special emphasis was put on the growth of the statoconia in the statocysts. In the statocysts of embryonic snails (90-120 h after oviposition) there is not a single statolith but an average of 40-50 statoconia per statocyst. The number of statoconia increases to 385-400 when the snails reach a shell diameter of 4 mm and remains relatively constant thereafter, irrespective of shell size. Small statoconia are found in supporting cells, which suggests that the statoconia are produced within these cells. The average diameter of statoconia and the total mass of statoconia increase with increasing shell diameter. The average number of large statoconia (diameter greater than 7 micrometers) per statocyst continues to increase from 2 to 10 mm animals while the number of small ones (diameter less than 4 micrometers) initially rises and then decreases after 4 mm. These results demonstrate continuous growth of the statoconia in the cyst lumen of Biomphalaria. The single statoconia vibrate in a regular pattern in vivo, indicating beating of the statocyst cilia. The statoconia sink under the influence of gravity to load and stimulate receptor cells which are at the bottom. The length of cilia and the size of statocyst gradually increase as the animal grows. However, the increase in the volume of the statocyst is relatively small compared with the increase in body weight during normal development.
Synthesis of copper nanocolloids using a continuous flow based microreactor
NASA Astrophysics Data System (ADS)
Xu, Lei; Peng, Jinhui; Srinivasakannan, C.; Chen, Guo; Shen, Amy Q.
2015-11-01
The copper (Cu) nanocolloids were prepared by sodium borohydride (NaBH4) reduction of metal salt solutions in a T-shaped microreactor at room temperature. The influence of NaBH4 molar concentrations on copper particle's diameter, morphology, size distribution, and elemental compositions has been investigated by transmission electron microscopy (TEM) and X-ray diffraction (XRD). The ultraviolet-visible spectroscopy (UV-vis) was used to verify the chemical compounds of nanocolloids and estimate the average size of copper nanocolloids. The synthesized copper nanocolloids were uniform in size and non-oxidized. A decrease in the mean diameter of copper nanocolloids was observed with increasing NaBH4 molar concentrations. The maximum mean diameter (4.25 nm) occurred at the CuSO4/NaBH4 molar concentration ratio of 1:2.
Synthesis and Characterization of Molybdenum Based Colloidal Particles.
Moreno; Vidoni; Ovalles; Chaudret; Urbina; Krentzein
1998-11-15
The synthesis and characterization of molybdenum colloidal particles were evaluated using thermal and sonochemical methods and starting from different metal precursors, Mo(CO)6 and (NH4)2MoS4. The products were characterized by elemental analysis, spectroscopic (UV, FTIR), and surface analysis (XPS) techniques, as well as by transmission electron microscopy (TEM) for determining the particle sizes. Using Mo(CO)6 as metal source, particle sizes with an average diameter of 1.5 nm can be obtained using tert-amyl alcohol as solvent and tetrahydrothiophene as sulfurating ligand. The characterization of these particles showed that they are composed of molybdenum oxide MoO3. Using (NH4)2MoS4 as metal precursor, particles with average diameters of 4.7 and 2.5 nm were synthesized using thermal and sonochemical methods, respectively. The characterization of these particles showed them to be composed of molybdenum sulfide, MoS2. The sonochemical method proved to be the fastest and most convenient synthetic pathway of obtaining small colloidal particles at low temperatures and with control of the average size. Copyright 1998 Academic Press.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katalenich, Jeffrey A.; Kitchen, Brian B.; Pierson, Bruce
Cerium dioxide microspheres with uniform diameters between 65 – 211 µm were fabricated using internal gelation sol-gel methods. Although uniform microspheres are produced for nuclear fuel applications with diameters above 300 µm, sol-gel microspheres with diameters of 50 - 200 µm have historically been made by emulsion techniques and had poor size uniformity [1, 2]. An internal gelation, sol-gel apparatus was designed and constructed to accommodate the production of small, uniform microspheres whereby cerium-containing solutions were dispersed into flowing silicone oil and heated in a gelation column to initiate solidification [3, 4]. Problems with premature feed gelation and microsphere coalescencemore » were overcome by equipment modifications unique among known internal gelation setups. Microspheres were fabricated and sized in batches as a function of dispersing needle diameter and silicone oil flow rate in the two-fluid nozzle in order to determine the range of sizes possible and corresponding degree of monodispersity. Initial experiments with poor size uniformity were linked to microsphere coalescence in the gelation column prior to solidification as well as excessive flow rates for the cerium feed solution. Average diameter standard deviations as low as 2.23% were observed after optimization of flow rates and minimization of coalescence reactions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katalenich, Jeffrey A.; Kitchen, Brian B.; Pierson, Bruce D.
Cerium dioxide microspheres with uniform diameters between 65 – 211 µm were fabricated using internal gelation sol-gel methods. Although uniform microspheres are produced for nuclear fuel applications with diameters above 300 µm, sol-gel microspheres with diameters of 50 - 200 µm have historically been made by emulsion techniques and had poor size uniformity [1, 2]. An internal gelation, sol-gel apparatus was designed and constructed to accommodate the production of small, uniform microspheres whereby cerium-containing solutions were dispersed into flowing silicone oil and heated in a gelation column to initiate solidification [3, 4]. Problems with premature feed gelation and microsphere coalescencemore » were overcome by equipment modifications unique among known internal gelation setups. Microspheres were fabricated and sized in batches as a function of dispersing needle diameter and silicone oil flow rate in the two-fluid nozzle in order to determine the range of sizes possible and corresponding degree of monodispersity. Initial experiments with poor size uniformity were linked to microsphere coalescence in the gelation column prior to solidification as well as excessive flow rates for the cerium feed solution. Average diameter standard deviations as low as 2.23% were observed after optimization of flow rates and minimization of coalescence reactions.« less
NASA Astrophysics Data System (ADS)
Caparanga, Alvin R.; Reyes, Rachael Anne L.; Rivas, Reiner L.; De Vera, Flordeliza C.; Retnasamy, Vithyacharan; Aris, Hasnizah
2017-11-01
This study utilized the 3k factorial design with k as the two varying factors namely, temperature and air velocity. The effects of temperature and air velocity on the drying rate curves and on the average particle diameter of the arrowroot starch were investigated. Extracted arrowroot starch samples were dried based on the designed parameters until constant weight was obtained. The resulting initial moisture content of the arrowroot starch was 49.4%. Higher temperatures correspond to higher drying rates and faster drying time while air velocity effects were approximately negligible or had little effect. Drying rate is a function of temperature and time. The constant rate period was not observed for the drying rate of arrowroot starch. The drying curves were fitted against five mathematical models: Lewis, Page, Henderson and Pabis, Logarithmic and Midili. The Midili Model was the best fit for the experimental data since it yielded the highest R2 and the lowest RSME values for all runs. Scanning electron microscopy (SEM) was used for qualitative analysis and for determination of average particle diameter of the starch granules. The starch granules average particle diameter had a range of 12.06 - 24.60 μm. The use of ANOVA proved that particle diameters for each run varied significantly with each other. And, the Taguchi Design proved that high temperatures yield lower average particle diameter, while high air velocities yield higher average particle diameter.
SU-F-18C-11: Diameter Dependency of the Radial Dose Distribution in a Long Polyethylene Cylinder
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bakalyar, D; McKenney, S; Feng, W
Purpose: The radial dose distribution in the central plane of a long cylinder following a long CT scan depends upon the diameter and composition of the cylinder. An understanding of this behavior is required for determining the spatial average of the dose in the central plane. Polyethylene, the material for construction of the TG200/ICRU phantom (30 cm in diameter) was used for this study. Size effects are germane to the principles incorporated in size specific dose estimates (SSDE); thus diameter dependency was explored as well. Method: ssuming a uniform cylinder and cylindrically symmetric conditions of irradiation, the dose distribution canmore » be described using a radial function. This function must be an even function of the radial distance due to the conditions of symmetry. Two effects are accounted for: The direct beam makes its weakest contribution at the center while the contribution due to scatter is strongest at the center and drops off abruptly at the outer radius. An analytic function incorporating these features was fit to Monte Carlo results determined for infinite polyethylene cylinders of various diameters. A further feature of this function is that it is integrable. Results: Symmetry and continuity dictate a local extremum at the center which is a minimum for the larger sizes. The competing effects described above can Resultin an absolute maximum occurring between the center and outer edge of the cylinders. For the smallest cylinders, the maximum dose may occur at the center. Conclusion: An integrable, analytic function can be used to characterize the radial dependency of dose for cylindrical CT phantoms of various sizes. One use for this is to help determine average dose distribution over the central cylinder plane when equilibrium dose has been reached.« less
NASA Astrophysics Data System (ADS)
Contini, D.; Donateo, A.; Belosi, F.; Grasso, F. M.; Santachiara, G.; Prodi, F.
2010-08-01
This work reports an analysis of the concentration, size distribution, and deposition velocity of atmospheric particles over snow and iced surfaces on the Nansen Ice Sheet (Antarctica). Measurements were performed using the eddy-correlation method at a remote site during the XXII Italian expedition of the National Research Program in Antarctica (PNRA) in 2006. The measurement system was based on a condensation particle counter (CPC) able to measure particles down to 9 nm in diameter with a 50% efficiency and a Differential Mobility Particle Sizer for evaluating particle size distributions from 11 to 521 nm diameter in 39 channels. A method based on postprocessing with digital filters was developed to take into account the effect of the slow time response of the CPC. The average number concentration was 1338 cm-3 (median, 978 cm-3; interquartile range, 435-1854 cm-3). Higher concentrations were observed at low wind velocities. Results gave an average deposition velocity of 0.47 mm/s (median, 0.19 mm/s; interquartile range, -0.21 -0.88 mm/s). Deposition increased with the friction velocity and was on average 0.86 mm/s during katabatic wind characterized by velocities higher than 4 m/s. Observed size distributions generally presented two distinct modes, the first at approximately 15-20 nm and the second (representing on average 70% of the total particles) at 60-70 nm. Under strong-wind conditions, the second mode dominated the average size distribution.
Measurements of droplet size in shear-driven atomization using ultra-small angle x-ray scattering
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kastengren, A.; Ilavsky, J.; Viera, Juan Pablo
Measurements of droplet size in optically-thick, non-evaporating, shear-driven sprays have been made using ultra-small angle x-ray scattering (USAXS). The sprays are produced by orifice-type nozzles coupled to diesel injectors, with measurements conducted from 1 – 24 mm from the orifice, spanning from the optically-dense near-nozzle region to more dilute regions where optical diagnostics are feasible. The influence of nozzle diameter, liquid injection pressure, and ambient density were examined. The USAXS measurements reveal few if any nanoscale droplets, in conflict with a popular computational model of diesel spray breakup. The average droplet diameter rapidly decreases with downstream distance from the nozzlemore » until a plateau value is reached, after which only small changes are seen in droplet diameter. This plateau droplet size is consistent with the droplets being small enough to be stable with respect to further breakup. As a result, liquid injection pressure and nozzle diameter have the biggest impact on droplet size, while ambient density has a smaller effect.« less
Measurements of droplet size in shear-driven atomization using ultra-small angle x-ray scattering
Kastengren, A.; Ilavsky, J.; Viera, Juan Pablo; ...
2017-03-16
Measurements of droplet size in optically-thick, non-evaporating, shear-driven sprays have been made using ultra-small angle x-ray scattering (USAXS). The sprays are produced by orifice-type nozzles coupled to diesel injectors, with measurements conducted from 1 – 24 mm from the orifice, spanning from the optically-dense near-nozzle region to more dilute regions where optical diagnostics are feasible. The influence of nozzle diameter, liquid injection pressure, and ambient density were examined. The USAXS measurements reveal few if any nanoscale droplets, in conflict with a popular computational model of diesel spray breakup. The average droplet diameter rapidly decreases with downstream distance from the nozzlemore » until a plateau value is reached, after which only small changes are seen in droplet diameter. This plateau droplet size is consistent with the droplets being small enough to be stable with respect to further breakup. As a result, liquid injection pressure and nozzle diameter have the biggest impact on droplet size, while ambient density has a smaller effect.« less
Influence of multiple brain metastases’ size and number on the quality of SRS - VMAT dose delivery
NASA Astrophysics Data System (ADS)
Prentou, G.; Koutsouveli, E.; Pantelis, E.; Papagiannis, P.; Georgiou, E.; Karaiskos, P.
2017-11-01
Stereotactic radiosurgery with volumetric modulated arc therapy (SRS-VMAT) has recently been introduced for treatment of multiple brain metastases with a single isocenter. The technique’s high efficiency is nevertheless dependent of metastatic tumors’ characteristics such as size and number. In this work the impact of the metastases’ size and number on the plan quality indices clinically used for plan evaluation and acceptance is investigated. Fifteen targets with a diameter of 1 cm and average volume of 0.7 cm3 and ten targets with a diameter of 2 cm and average volume of 6.5 cm3 were contoured on an anonymized patient CT dataset, in Monaco (Elekta) treatment planning system. VMAT plans for different target volumes (1 and 2 cm in diameter) and various target numbers (1-15) were generated using four non-coplanar arcs and the Agility (Elekta) linear accelerator (5 mm MLC width) using a Monte Carlo dose calculation algorithm and 1mm dose calculation grid resolution. Conformity index (CI), gradient index (GI) and heterogeneity index (HI) were determined for each target. High quality plans were created for both 1 cm and 2 cm in diameter targets for limited (<6) number of targets per plan. For increased number of irradiated targets (>6) both CI and GI, clinically used for plan evaluation and acceptance, were found to deteriorate.
Determining size-specific emission factors for environmental tobacco smoke particles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klepeis, Neil E.; Apte, Michael G.; Gundel, Lara A.
Because size is a major controlling factor for indoor airborne particle behavior, human particle exposure assessments will benefit from improved knowledge of size-specific particle emissions. We report a method of inferring size-specific mass emission factors for indoor sources that makes use of an indoor aerosol dynamics model, measured particle concentration time series data, and an optimization routine. This approach provides--in addition to estimates of the emissions size distribution and integrated emission factors--estimates of deposition rate, an enhanced understanding of particle dynamics, and information about model performance. We applied the method to size-specific environmental tobacco smoke (ETS) particle concentrations measured everymore » minute with an 8-channel optical particle counter (PMS-LASAIR; 0.1-2+ micrometer diameters) and every 10 or 30 min with a 34-channel differential mobility particle sizer (TSI-DMPS; 0.01-1+ micrometer diameters) after a single cigarette or cigar was machine-smoked inside a low air-exchange-rate 20 m{sup 3} chamber. The aerosol dynamics model provided good fits to observed concentrations when using optimized values of mass emission rate and deposition rate for each particle size range as input. Small discrepancies observed in the first 1-2 hours after smoking are likely due to the effect of particle evaporation, a process neglected by the model. Size-specific ETS particle emission factors were fit with log-normal distributions, yielding an average mass median diameter of 0.2 micrometers and an average geometric standard deviation of 2.3 with no systematic differences between cigars and cigarettes. The equivalent total particle emission rate, obtained integrating each size distribution, was 0.2-0.7 mg/min for cigars and 0.7-0.9 mg/min for cigarettes.« less
Evaporation of Liquid Droplet in Nano and Micro Scales from Statistical Rate Theory.
Duan, Fei; He, Bin; Wei, Tao
2015-04-01
The statistical rate theory (SRT) is applied to predict the average evaporation flux of liquid droplet after the approach is validated in the sessile droplet experiments of the water and heavy water. The steady-state experiments show a temperature discontinuity at the evaporating interface. The average evaporation flux is evaluated by individually changing the measurement at a liquid-vapor interface, including the interfacial liquid temperature, the interfacial vapor temperature, the vapor-phase pressure, and the droplet size. The parameter study shows that a higher temperature jump would reduce the average evaporation flux. The average evaporation flux can significantly be influenced by the interfacial liquid temperature and the vapor-phase pressure. The variation can switch the evaporation into condensation. The evaporation flux is found to remain relative constant if the droplet is larger than a micro scale, while the smaller diameters in nano scale can produce a much higher evaporation flux. In addition, a smaller diameter of droplets with the same liquid volume has a larger surface area. It is suggested that the evaporation rate increases dramatically as the droplet shrinks into nano size.
Effect of Pellet Size of Defoliation and Estimated Kill of Small Stems Treated with Hexazinone
J.L. Michael
1981-01-01
Hexazinone [3-cyclohexyl-6-(dimethylamino)-1-methyl-1,2,5-triaine-2,4,(1H,2H)-dione] was tested in the 2, 1, and 0.5 cc size uellet (10% ai) against very small stems [average height, 1.97m; average ground line diameter (GLD), 2 cm] of water oak, Quercus nigra L., at 1.12 and 2.24 kg/ha on a sandy loam soil. First year defoliation of water oak by...
7 CFR 51.2113 - Size requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... of range in count of whole almond kernels per ounce or in terms of minimum, or minimum and maximum diameter. When a range in count is specified, the whole kernels shall be fairly uniform in size, and the average count per ounce shall be within the range specified. Doubles and broken kernels shall not be used...
Composition distributions in FePt(Au) nanoparticles
NASA Astrophysics Data System (ADS)
Srivastava, C.; Nikles, D. E.; Harrell, J. W.; Thompson, G. B.
2010-08-01
Ternary alloy FePt(Au) nanoparticles were prepared by the co-reduction of platinum(II) acetylacetonate and gold(III) acetate and the thermal decomposition of iron pentacarbonyl in hot phenyl ether in the presence of oleic acid and oleylamine ligands. This gave spherical particles with an average diameter of 4.4 nm with a range of diameters from approximately 1.6-9 nm. The as-synthesized particles had a solid solution, face-centered-cubic structure. Though the average composition of the particles was Fe44Pt45Au11, individual particle analysis by Scanning Transmission Electron Microscopy-X-ray Energy Dispersive Spectroscopy showed a broad distribution in composition. In general, smaller-sized particles tended to have a lower amount of Au as compared to larger-sized particles. As the Au content increased, the ratio of Fe/Pt widened.
NASA Astrophysics Data System (ADS)
Tritscher, Torsten; Koched, Amine; Han, Hee-Siew; Filimundi, Eric; Johnson, Tim; Elzey, Sherrie; Avenido, Aaron; Kykal, Carsten; Bischof, Oliver F.
2015-05-01
Electrical mobility classification (EC) followed by Condensation Particle Counter (CPC) detection is the technique combined in Scanning Mobility Particle Sizers(SMPS) to retrieve nanoparticle size distributions in the range from 2.5 nm to 1 μm. The detectable size range of SMPS systems can be extended by the addition of an Optical Particle Sizer(OPS) that covers larger sizes from 300 nm to 10 μm. This optical sizing method reports an optical equivalent diameter, which is often different from the electrical mobility diameter measured by the standard SMPS technique. Multi-Instrument Manager (MIMTM) software developed by TSI incorporates algorithms that facilitate merging SMPS data sets with data based on optical equivalent diameter to compile single, wide-range size distributions. Here we present MIM 2.0, the next-generation of the data merging tool that offers many advanced features for data merging and post-processing. MIM 2.0 allows direct data acquisition with OPS and NanoScan SMPS instruments to retrieve real-time particle size distributions from 10 nm to 10 μm, which we show in a case study at a fireplace. The merged data can be adjusted using one of the merging options, which automatically determines an overall aerosol effective refractive index. As a result an indirect and average characterization of aerosol optical and shape properties is possible. The merging tool allows several pre-settings, data averaging and adjustments, as well as the export of data sets and fitted graphs. MIM 2.0 also features several post-processing options for SMPS data and differences can be visualized in a multi-peak sample over a narrow size range.
NASA Astrophysics Data System (ADS)
Rajabzadeh-Oghaz, Hamidreza; Varble, Nicole; Davies, Jason M.; Mowla, Ashkan; Shakir, Hakeem J.; Sonig, Ashish; Shallwani, Hussain; Snyder, Kenneth V.; Levy, Elad I.; Siddiqui, Adnan H.; Meng, Hui
2017-03-01
Neurosurgeons currently base most of their treatment decisions for intracranial aneurysms (IAs) on morphological measurements made manually from 2D angiographic images. These measurements tend to be inaccurate because 2D measurements cannot capture the complex geometry of IAs and because manual measurements are variable depending on the clinician's experience and opinion. Incorrect morphological measurements may lead to inappropriate treatment strategies. In order to improve the accuracy and consistency of morphological analysis of IAs, we have developed an image-based computational tool, AView. In this study, we quantified the accuracy of computer-assisted adjuncts of AView for aneurysmal morphologic assessment by performing measurement on spheres of known size and anatomical IA models. AView has an average morphological error of 0.56% in size and 2.1% in volume measurement. We also investigate the clinical utility of this tool on a retrospective clinical dataset and compare size and neck diameter measurement between 2D manual and 3D computer-assisted measurement. The average error was 22% and 30% in the manual measurement of size and aneurysm neck diameter, respectively. Inaccuracies due to manual measurements could therefore lead to wrong treatment decisions in 44% and inappropriate treatment strategies in 33% of the IAs. Furthermore, computer-assisted analysis of IAs improves the consistency in measurement among clinicians by 62% in size and 82% in neck diameter measurement. We conclude that AView dramatically improves accuracy for morphological analysis. These results illustrate the necessity of a computer-assisted approach for the morphological analysis of IAs.
Saharan Dust Particle Size And Concentration Distribution In Central Ghana
NASA Astrophysics Data System (ADS)
Sunnu, A. K.
2010-12-01
A.K. Sunnu*, G. M. Afeti* and F. Resch+ *Department of Mechanical Engineering, Kwame Nkrumah University of Science and Technology (KNUST) Kumasi, Ghana. E-mail: albertsunnu@yahoo.com +Laboratoire Lepi, ISITV-Université du Sud Toulon-Var, 83162 La Valette cedex, France E-mail: resch@univ-tln.fr Keywords: Atmospheric aerosol; Saharan dust; Particle size distributions; Particle concentrations. Abstract The Saharan dust that is transported and deposited over many countries in the West African atmospheric environment (5°N), every year, during the months of November to March, known locally as the Harmattan season, have been studied over a 13-year period, between 1996 and 2009, using a location at Kumasi in central Ghana (6° 40'N, 1° 34'W) as the reference geographical point. The suspended Saharan dust particles were sampled by an optical particle counter, and the particle size distributions and concentrations were analysed. The counter gives the total dust loads as number of particles per unit volume of air. The optical particle counter used did not discriminate the smoke fractions (due to spontaneous bush fires during the dry season) from the Saharan dust. Within the particle size range measured (0.5 μm-25 μm.), the average inter-annual mean particle diameter, number and mass concentrations during the northern winter months of January and February were determined. The average daily number concentrations ranged from 15 particles/cm3 to 63 particles/cm3 with an average of 31 particles/cm3. The average daily mass concentrations ranged from 122 μg/m3 to 1344 μg/m3 with an average of 532 μg/m3. The measured particle concentrations outside the winter period were consistently less than 10 cm-3. The overall dust mean particle diameter, analyzed from the peak representative Harmattan periods over the 13-year period, ranged from 0.89 μm to 2.43 μm with an average of 1.5 μm ± 0.5. The particle size distributions exhibited the typical distribution pattern for atmospheric aerosols with a coarse mode diameter situated at about 3.5 μm. The experimental results reported in this study will be important in validating satellite based observations and simulation models of the African dust plume towards the Gulf of Guinea during winter.
Danaei, M; Dehghankhold, M; Ataei, S; Hasanzadeh Davarani, F; Javanmard, R; Dokhani, A; Khorasani, S; Mozafari, M R
2018-05-18
Lipid-based drug delivery systems, or lipidic carriers, are being extensively employed to enhance the bioavailability of poorly-soluble drugs. They have the ability to incorporate both lipophilic and hydrophilic molecules and protecting them against degradation in vitro and in vivo. There is a number of physical attributes of lipid-based nanocarriers that determine their safety, stability, efficacy, as well as their in vitro and in vivo behaviour. These include average particle size/diameter and the polydispersity index (PDI), which is an indication of their quality with respect to the size distribution. The suitability of nanocarrier formulations for a particular route of drug administration depends on their average diameter, PDI and size stability, among other parameters. Controlling and validating these parameters are of key importance for the effective clinical applications of nanocarrier formulations. This review highlights the significance of size and PDI in the successful design, formulation and development of nanosystems for pharmaceutical, nutraceutical and other applications. Liposomes, nanoliposomes, vesicular phospholipid gels, solid lipid nanoparticles, transfersomes and tocosomes are presented as frequently-used lipidic drug carriers. The advantages and limitations of a range of available analytical techniques used to characterize lipidic nanocarrier formulations are also covered.
NASA Astrophysics Data System (ADS)
Colmenares Roldán, Gabriel Jaime; Agudelo Gomez, Liliana María; Carlos Cornelio, Jesús Antonio; Rodriguez, Luis Fernando; Pinal, Rodolfo; Hoyos Palacio, Lina Marcela
2018-03-01
Encapsulation and controlled release of substances using polymeric nanoparticles require that these have a high reproducibility, homogeneity, and control over their properties (diameter and polydispersity), especially when they are to be used in medical, pharmaceutical, or nutritional applications among others. In conventional production systems, it is tough to ensure these characteristics; hence, the cost increases when we try to control these properties. This paper shows a comparison between a recirculating system and the standard nanoprecipitation technique for producing polymeric nanoparticles. In previous investigations, we evaluate the effect of recirculating flow and the ratio between the organic and aqueous phase. For this paper, we evaluated the effect of polymer and surfactant concentrations using a multifactorial design of experiments on the recirculating system and on the standard nanoprecipitation system. The response of the design was the average diameter of the nanoparticles and polydispersity index. Finally, we found that the polymer and surfactant concentrations could change the average diameter and polydispersity index of the nanoparticles obtained. On the other hand, it was found that the effect of the polymer concentration was stronger than the surfactant concentration to reduce the average diameter of the nanoparticles. The results of the present study show that the proposed recirculation system presents a high potential to produce polymer nanoparticles with good morphological characteristics, particle size distributions in the nano range, and with a low polydispersity. The average mean size of nanoparticles of polycaprolactone for the design using the recirculating system was of 61 to 140 nm and the values of polydispersity index PDI for this design were between 0.097 and 0.22, while for the design using the standard nanoprecipitation technique, the obtained diameters were 74 to 176 nm and the polydispersity was between 0.26 and 0.41.
Diameter control of single-walled carbon nanotube forests from 1.3–3.0 nm by arc plasma deposition
Chen, Guohai; Seki, Yasuaki; Kimura, Hiroe; Sakurai, Shunsuke; Yumura, Motoo; Hata, Kenji; Futaba, Don N.
2014-01-01
We present a method to both precisely and continuously control the average diameter of single-walled carbon nanotubes in a forest ranging from 1.3 to 3.0 nm with ~1 Å resolution. The diameter control of the forest was achieved through tuning of the catalyst state (size, density, and composition) using arc plasma deposition of nanoparticles. This 1.7 nm control range and 1 Å precision exceed the highest reports to date. PMID:24448201
Conghe Song; Matthew B. Dickinson; Lihong Su; Su Zhang; Daniel Yaussey
2010-01-01
The forest canopy is the medium for energy, mass, and momentum exchanges between the forest ecosystem and the atmosphere. Tree crown size is a critical aspect of canopy structure that significantly influences these biophysical processes in the canopy. Tree crown size is also strongly related to other canopy structural parameters, such as tree height, diameter at breast...
Particle Morphology and Size Results from the Smoke Aerosol Measurement Experiment-2
NASA Technical Reports Server (NTRS)
Urban, David L.; Ruff, Gary A.; Greenberg, Paul S.; Fischer, David; Meyer, Marit; Mulholland, George; Yuan, Zeng-Guang; Bryg, Victoria; Cleary, Thomas; Yang, Jiann
2012-01-01
Results are presented from the Reflight of the Smoke Aerosol Measurement Experiment (SAME-2) which was conducted during Expedition 24 (July-September 2010). The reflight experiment built upon the results of the original flight during Expedition 15 by adding diagnostic measurements and expanding the test matrix. Five different materials representative of those found in spacecraft (Teflon, Kapton, cotton, silicone rubber and Pyrell) were heated to temperatures below the ignition point with conditions controlled to provide repeatable sample surface temperatures and air flow. The air flow past the sample during the heating period ranged from quiescent to 8 cm/s. The smoke was initially collected in an aging chamber to simulate the transport time from the smoke source to the detector. This effective transport time was varied by holding the smoke in the aging chamber for times ranging from 11 to 1800 s. Smoke particle samples were collected on Transmission Electron Microscope (TEM) grids for post-flight analysis. The TEM grids were analyzed to observe the particle morphology and size parameters. The diagnostics included a prototype two-moment smoke detector and three different measures of moments of the particle size distribution. These moment diagnostics were used to determine the particle number concentration (zeroth moment), the diameter concentration (first moment), and the mass concentration (third moment). These statistics were combined to determine the diameter of average mass and the count mean diameter and, by assuming a log-normal distribution, the geometric mean diameter and the geometric standard deviations can also be calculated. Overall the majority of the average smoke particle sizes were found to be in the 200 nm to 400 nm range with the quiescent cases producing some cases with substantially larger particles.
Evaluation of Low-Gravity Smoke Particulate for Spacecraft Fire Detection
NASA Technical Reports Server (NTRS)
Urban, David; Ruff, Gary A.; Mulholland George; Meyer, Marit; Yuan, Zeng guang; Cleary, Thomas; Yang, Jiann; Greenberg, Paul; Bryg, Victoria
2013-01-01
Tests were conducted on the International Space Station to evaluate the smoke particulate size from materials and conditions that are typical of those expected in spacecraft fires. Five different materials representative of those found in spacecraft (Teflon, Kapton, cotton, silicone rubber and Pyrell) were heated to temperatures below the ignition point with conditions controlled to provide repeatable sample surface temperatures and air flow. The air flow past the sample during the heating period ranged from quiescent to 8 cm/s. The effective transport time to the measurement instruments was varied from 11 to 800 seconds to simulate different smoke transport conditions in spacecraft. The resultant aerosol was evaluated by three instruments which measured different moments of the particle size distribution. These moment diagnostics were used to determine the particle number concentration (zeroth moment), the diameter concentration (first moment), and the mass concentration (third moment). These statistics were combined to determine the diameter of average mass and the count mean diameter and by assuming a log-normal distribution, the geometric mean diameter and the geometric standard deviations were also calculated. Smoke particle samples were collected on TEM grids using a thermal precipitator for post flight analysis. The TEM grids were analyzed to determine the particle morphology and shape parameters. The different materials produced particles with significantly different morphologies. Overall the majority of the average smoke particle sizes were found to be in the 200 to 400 nanometer range with the quiescent cases and the cases with increased transport time typically producing with substantially larger particles. The results varied between materials but the smoke particles produced in low gravity were typically twice the size of particles produced in normal gravity. These results can be used to establish design requirements for future spacecraft smoke detectors.
Morphology of meteoroid and space debris craters on LDEF metal targets
NASA Technical Reports Server (NTRS)
Love, S. G.; Brownlee, D. E.; King, N. L.; Hoerz, F.
1994-01-01
We measured the depths, average diameters, and circularity indices of over 600 micrometeoroid and space debris craters on various metal surfaces exposed to space on the Long Duration Exposure Facility (LDEF) satellite, as a test of some of the formalisms used to convert the diameters of craters on space-exposed surfaces into penetration depths for the purpose of calculating impactor sizes or masses. The topics covered include the following: targe materials orientation; crater measurements and sample populations; effects of oblique impacts; effects of projectile velocity; effects of crater size; effects of target hardness; effects of target density; and effects of projectile properties.
Tree Sizes Harvested in Different Thinnings -- Another Look
W.F. Mann; D.P. Feduccia
1976-01-01
In loblolly planted at 10 by 10 feet, light- and medium- thinned plots had slightly more sawtimber-sized trees and board-foot volume than unthinned checks and heavily thinned plots at all ages. Average diameters of all trees were largest on checks, followed by light-thinned plots. Trends were similar for 32-year-old slash pine planted at 6 by 7 feet.
A.R. Weiskittel; R.A. Monserud; R. Rose; E.C. Turnblom; Douglas A. Maguire
2006-01-01
Intensive management may adversely affect lumber yield and quality by increasing knot size and creating a more conical stem form with a greater average rate of taper. This study was initiated to examine the impact of management on simulated lumber yield and quality. Stem diameter and branch size and location of 223 Pseudotsuga menziesii (Mirb.)...
Kilgour, Morgan J; Shirley, Thomas C
2014-01-16
Reproductive timing, fecundity, and average egg sizes were examined for galatheoid and chirostyloid squat lobster collections from the Gulf of Mexico. While congeners did not always significantly differ in egg size or timing, each genus had a unique average egg diameter size which may indicate whether the developing embryos will be lecithotrophic or planktotrophic larvae. The eggs of Eumunididae, Galatheidae, and Munididae were more numerous and smaller than the larger and less abundant eggs of Chirostylidae and Munidopsidae. With the exception of members of the Munididae, members of genera within the same family had distinct egg diameters. Ovigerous females were significantly larger than non-ovigerous females in some species (i.e., Uroptychus nitidus, Munida forceps, Galacantha spinosa, Munidopsis abbreviata, M. alaminos, M., erinacea, M. robusta, M. sigsbei, and M. simplex). Munidopsis erinacea and Munida affinis males were significantly larger than females; the reverse was true for Munidopsis robusta and Munidopsis simplex. All other species studied did not have a significant difference between males and females. The spatial and bathymetric ranges for many species are extended in this study from prior reports. Seasonality of reproduction was evident in few species, but this may be a result of limited sample sizes.
Evaluation of actual vs expected photodynamic therapy spot size.
Ranchod, Tushar M; Brucker, Alexander J; Liu, Chengcheng; Cukras, Catherine A; Hopkins, Tim B; Ying, Gui-Shuang
2009-05-01
To determine the accuracy of the photodynamic therapy (PDT) laser spot size on the retina as generated by 2 Food and Drug Administration (FDA)-approved lasers. Prospective observational case series. Fundus photographs were taken of 1 eye of each of 10 subjects with the WinStation 4000 fundus photography system (OIS; Ophthalmic Imaging Systems, Sacramento, California, USA); disc size was calculated using OIS software. Slit-lamp photographs were taken of the PDT laser spot focused on the retina adjacent to the optic disc, using various spot sizes in combination with 3 different contact lenses and 2 different lasers. Spot size at the retina was determined by measuring the ratio of disc diameter to spot diameter in Adobe Photoshop (San Jose, California, USA) and applying this ratio to the OIS disc measurements. Spot size at the retina averaged 87% of expected spot size for the Coherent Opal laser (Coherent Inc, Santa Clara, California, USA) and 104% of expected spot size for the Zeiss Visulas laser (Carl Zeiss Meditec Inc, Dublin, California, USA)(P = .002). Multivariate analysis demonstrated that percentage of expected spot size decreased with larger spot diameter (P = .01 for Coherent laser; P = .02 for Zeiss laser). PDT spot size at the retina appears to be consistently smaller than expected for the Coherent laser while the spot size was consistently within 10% of expected size for the Zeiss laser. The deviation from expected size increased with larger spot size using the Coherent laser.
Łuszczewska-Sierakowska, Iwona; Wawrzyniak-Gacek, Agata; Guz, Tomasz; Tatara, Marcin R; Charuta, Anna
2015-01-01
The aim of the study was a quantitative examination of neurons of hippocampal subfields (CA1-CA4) in mature male Arctic fox (Vulpes lagopus; syn. Alopex lagopus). The preparations were dyed using cresyl violet. Histological preparations were used to morphometricaly analyze the neurons of hippocampus. This analysis included the following parameters: average size of cells in μm, periphery of cells in μm, average cell area in μm2, percentage of cells in area and size of the largest and smallest cells in μm in CA1-CA4 fields. Morphometric observations show that the cells involved in hippocampal formation in polar fox in all layers CA1 -CA4 differ in size, shape, cell area and nucleus area. The size of the cell area in CA3 is the largest and fluctuates around 249.4 μm2, whereas in CA2 the cell area is 184.1 μm2. The cells of the CA2 field are densely arranged, pyramidal and contain a small amount of cytoplasm; their size fluctuates. Cells of CA2 and CA4 had the largest diameter of about 23.6 μm, whereas cells of the CA3 field had the smallest diameter of about 8.3 μm.
NASA Astrophysics Data System (ADS)
Helwani, Z.; Fatra, W.; Arifin, L.; Othman, M. R.; Syapsan
2018-04-01
In this study, the manual hydraulic press was designed to prepare the briquettes from selected biomass waste. Each biomass was sun-dried and milled into small particle sizes before mixing with crude glycerol that used as a biomass binder. The effects of applied pressure levels of 100, 110, 120 bars, the particle size of 60, 80 and 100 mesh and the binder composition on the density, compressive strength and calorific heating value of the prepared briquettes were investigated using response surface methodology (RSM). Results showed that the briquettes have an average inside diameter, average outside diameter, and height of 12, 38, and 25-30 mm, respectively. The density of the briquettes increased with increasing the applied pressure, was in the range of 623-923 kg/m3. The densest briquettes were obtained at 80 mesh of particle size, 53:47 binder composition ratio and 110 bars of pressurizing. The heating value of the briquette reached up to 28.99 MJ/kg obtained on the particle size of 80 mesh, 53:47 binder composition, and 110 bars and the best compressive strength of 6.991 kg/cm2 obtained at a particle size of 100 mesh, 60:40 binder composition, and 120 bars. Process conditions influence the calorific value significantly.
Sacha, Gregory A; Schmitt, William J; Nail, Steven L
2006-01-01
The critical processing parameters affecting average particle size, particle size distribution, yield, and level of residual carrier solvent using the supercritical anti-solvent method (SAS) were identified. Carbon dioxide was used as the supercritical fluid. Methylprednisolone acetate was used as the model solute in tetrahydrofuran. Parameters examined included pressure of the supercritical fluid, agitation rate, feed solution flow rate, impeller diameter, and nozzle design. Pressure was identified as the most important process parameter affecting average particle size, either through the effect of pressure on dispersion of the feed solution into the precipitation vessel or through the effect of pressure on solubility of drug in the CO2/organic solvent mixture. Agitation rate, impeller diameter, feed solution flow rate, and nozzle design had significant effects on particle size, which suggests that dispersion of the feed solution is important. Crimped HPLC tubing was the most effective method of introducing feed solution into the precipitation vessel, largely because it resulted in the least amount of clogging during the precipitation. Yields of 82% or greater were consistently produced and were not affected by the processing variables. Similarly, the level of residual solvent was independent of the processing variables and was present at 0.0002% wt/wt THF or less.
Olive Oil Tracer Particle Size Analysis for Optical Flow Investigations in a Gas Medium
NASA Astrophysics Data System (ADS)
Harris, Shaun; Smith, Barton
2014-11-01
Seed tracer particles must be large enough to scatter sufficient light while being sufficiently small to follow the flow. These requirements motivate a desire for control over the particle size. For gas measurements, it is common to use atomized oil droplets as tracer particles. A Laskin nozzle is a device for generating oil droplets in air by directing high-pressure air through small holes under an oil surface. The droplet diameter frequency distribution can be varied by altering the hole diameter, the number of holes, or the inlet pressure. We will present a systematic study of the effect of these three parameters on the resultant particle distribution as it leaves the Laskin nozzle. The study was repeated for cases where the particles moved through a typical jet facility before their size was measured. While the jet facility resulted in an elimination of larger particles, the average particle diameter could be varied by a factor of two at both the seeder exit and downstream of the jet facility.
Wagner, Pablo; Ortiz, Cristian; Vela, Omar; Arias, Paul; Zanolli, Diego; Wagner, Emilio
2016-09-01
Tibialis posterior (TP) tendon transfer through the interosseous membrane is commonly performed in Charcot-Marie-Tooth disease. In order to avoid entrapment of this tendon, no clear recommendation relative to the interosseous membrane (IOM) incision size has been made. Analyze the TP size at the transfer level and therefore determine the most adequate IOM window size to avoid muscle entrapment. Eleven lower extremity magnetic resonances were analyzed. TP muscle measurements were made in axial views, obtaining the medial-lateral and antero-posterior diameter at various distances from the medial malleolus tip. The distance from the posterior to anterior compartment was also measured. These measurements were applied to a mathematical model to predict the IOM window size necessary to allow an ample TP passage in an oblique direction. The average tendon diameter (confidence-interval) at 15cm proximal to the medial malleolus tip was 19.47mm (17.47-21.48). The deep posterior compartment to anterior compartment distance was 10.97mm (9.03-12.90). Using a mathematical model, the estimated IOM window size ranges from 4.2 to 4.9cm. The IOM window size is of utmost importance in trans-membrane TP transfers, given that if equal or smaller than the transposed tendon oblique diameter, a high entrapment risk exists. A membrane window of 5cm or 2.5 times the size of the tendon diameter should be performed in order to theoretically diminish this complication. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Allagui, Anis; Alami, Abdul Hai; Baranova, Elena A.; Wüthrich, Rolf
2014-09-01
NiO nanoparticles of 70, 91 and 107 nm average diameter are synthesized by cathodic contact glow discharge electrolysis at 30, 36 and 42 VDC respectively, in 2 M H2SO4 + 0.5 M ethanol + 2.5 mg ml-1 of PVP, and are investigated for electrochemical energy storage. From the cyclic voltammetry and galvanostatic charge-discharge measurements in 1 M KOH, it was found that a maximum specific capacitance of 218 F g-1 is achieved with the 70 nm NiO nanoparticles at 2.7 A g-1. Larger nanoparticles of 91 and 107 nm diameter exhibit specific capacitances of 106 and 63 F g-1, respectively, suggesting a size-dependent capacitive performance enhanced with decreasing particles size.
Silicon crystallization in nanodot arrays organized by block copolymer lithography
NASA Astrophysics Data System (ADS)
Perego, Michele; Andreozzi, Andrea; Seguini, Gabriele; Schamm-Chardon, Sylvie; Castro, Celia; BenAssayag, Gerard
2014-12-01
Asymmetric polystyrene- b-polymethylmethacrylate (PS- b-PMMA) block copolymers are used to fabricate nanoporous PS templates with different pore diameter depending on the specific substrate neutralization protocol. The resulting polymeric templates are used as masks for the subsequent deposition of a thin ( h = 5 nm) amorphous Si layer by electron beam evaporation. After removal of the polymeric film and of the silicon excess, well-defined hexagonally packed amorphous Si nanodots are formed on the substrate. Their average diameter ( d < 20 nm), density (1.2 × 1011 cm-2), and lateral distribution closely mimic the original nanoporous template. Upon capping with SiO2 and high temperature annealing (1050 °C, N2), each amorphous Si nanodot rearranges in agglomerates of Si nanocrystals ( d < 4 nm). The average diameter and shape of these Si nanocrystals strongly depend on the size of the initial Si nanodot.
Measurements of stem diameter: implications for individual- and stand-level errors.
Paul, Keryn I; Larmour, John S; Roxburgh, Stephen H; England, Jacqueline R; Davies, Micah J; Luck, Hamish D
2017-08-01
Stem diameter is one of the most common measurements made to assess the growth of woody vegetation, and the commercial and environmental benefits that it provides (e.g. wood or biomass products, carbon sequestration, landscape remediation). Yet inconsistency in its measurement is a continuing source of error in estimates of stand-scale measures such as basal area, biomass, and volume. Here we assessed errors in stem diameter measurement through repeated measurements of individual trees and shrubs of varying size and form (i.e. single- and multi-stemmed) across a range of contrasting stands, from complex mixed-species plantings to commercial single-species plantations. We compared a standard diameter tape with a Stepped Diameter Gauge (SDG) for time efficiency and measurement error. Measurement errors in diameter were slightly (but significantly) influenced by size and form of the tree or shrub, and stem height at which the measurement was made. Compared to standard tape measurement, the mean systematic error with SDG measurement was only -0.17 cm, but varied between -0.10 and -0.52 cm. Similarly, random error was relatively large, with standard deviations (and percentage coefficients of variation) averaging only 0.36 cm (and 3.8%), but varying between 0.14 and 0.61 cm (and 1.9 and 7.1%). However, at the stand scale, sampling errors (i.e. how well individual trees or shrubs selected for measurement of diameter represented the true stand population in terms of the average and distribution of diameter) generally had at least a tenfold greater influence on random errors in basal area estimates than errors in diameter measurements. This supports the use of diameter measurement tools that have high efficiency, such as the SDG. Use of the SDG almost halved the time required for measurements compared to the diameter tape. Based on these findings, recommendations include the following: (i) use of a tape to maximise accuracy when developing allometric models, or when monitoring relatively small changes in permanent sample plots (e.g. National Forest Inventories), noting that care is required in irregular-shaped, large-single-stemmed individuals, and (ii) use of a SDG to maximise efficiency when using inventory methods to assess basal area, and hence biomass or wood volume, at the stand scale (i.e. in studies of impacts of management or site quality) where there are budgetary constraints, noting the importance of sufficient sample sizes to ensure that the population sampled represents the true population.
A Comparison of Crater-Size Scaling and Ejection-Speed Scaling During Experimental Impacts in Sand
NASA Technical Reports Server (NTRS)
Anderson, J. L. B.; Cintala, M. J.; Johnson, M. K.
2014-01-01
Non-dimensional scaling relationships are used to understand various cratering processes including final crater sizes and the excavation of material from a growing crater. The principal assumption behind these scaling relationships is that these processes depend on a combination of the projectile's characteristics, namely its diameter, density, and impact speed. This simplifies the impact event into a single point-source. So long as the process of interest is beyond a few projectile radii from the impact point, the point-source assumption holds. These assumptions can be tested through laboratory experiments in which the initial conditions of the impact are controlled and resulting processes measured directly. In this contribution, we continue our exploration of the congruence between crater-size scaling and ejection-speed scaling relationships. In particular, we examine a series of experimental suites in which the projectile diameter and average grain size of the target are varied.
Velu, Juliëtte F; Groot Jebbink, Erik; de Vries, Jean-Paul P M; Slump, Cornelis H; Geelkerken, Robert H
2017-02-01
An important determinant of successful endovascular aortic aneurysm repair is proper sizing of the dimensions of the aortic-iliac vessels. The goal of the present study was to determine the concurrent validity, a method for comparison of test scores, for EVAR sizing and planning of the recently introduced Simbionix PROcedure Rehearsal Studio (PRORS). Seven vascular specialists analyzed anonymized computed tomography angiography scans of 70 patients with an infrarenal aneurysm of the abdominal aorta, using three different sizing software packages Simbionix PRORS (Simbionix USA Corp., Cleveland, OH, USA), 3mensio (Pie Medical Imaging BV, Maastricht, The Netherlands), and TeraRecon (Aquarius, Foster City, CA, USA). The following measurements were included in the protocol: diameter 1 mm below the most distal main renal artery, diameter 15 mm below the lowest renal artery, maximum aneurysm diameter, and length from the most distal renal artery to the left iliac artery bifurcation. Averaged over the locations, the intraclass correlation coefficient is 0.83 for Simbionix versus 3mensio, 0.81 for Simbionix versus TeraRecon, and 0.86 for 3mensio versus TeraRecon. It can be concluded that the Simbionix sizing software is as precise as two other validated and commercially available software packages.
The kilometer-sized Main Belt asteroid population revealed by Spitzer
NASA Astrophysics Data System (ADS)
Ryan, E. L.; Mizuno, D. R.; Shenoy, S. S.; Woodward, C. E.; Carey, S. J.; Noriega-Crespo, A.; Kraemer, K. E.; Price, S. D.
2015-06-01
Aims: Multi-epoch Spitzer Space Telescope 24 μm data is utilized from the MIPSGAL and Taurus Legacy surveys to detect asteroids based on their relative motion. Methods: Infrared detections are matched to known asteroids and average diameters and albedos are derived using the near Earth asteroid thermal model (NEATM) for 1865 asteroids ranging in size from 0.2 to 169 km. A small subsample of these objects was also detected by IRAS or MSX and the single wavelength albedo and diameter fits derived from these data are within the uncertainties of the IRAS and/or MSX derived albedos and diameters and available occultation diameters, which demonstrates the robustness of our technique. Results: The mean geometric albedo of the small Main Belt asteroids in this sample is pV = 0.134 with a sample standard deviation of 0.106. The albedo distribution of this sample is far more diverse than the IRAS or MSX samples. The cumulative size-frequency distribution of asteroids in the Main Belt at small diameters is directly derived and a 3σ deviation from the fitted size-frequency distribution slope is found near 8 km. Completeness limits of the optical and infrared surveys are discussed. Tables 1-3 are only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (ftp://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/578/A42
[Adaptability of sweet corn ears to a frozen process].
Ramírez Matheus, Alejandra O; Martínez, Norelkys Maribel; de Bertorelli, Ligia O; De Venanzi, Frank
2004-12-01
The effects of frozen condition on the quality of three sweet corn ears (2038, 2010, 2004) and the pattern (Bonanza), were evaluated. Biometrics characteristics like ear size, ear diameter, row and kernel deep were measured as well as chemical and physical measurement in fresh and frozen states. The corn ears were frozen at -95 degrees C by 7 minutes. The yield and stability of the frozen ears were evaluated at 45 and 90 days of frozen storage (-18 degrees C). The average commercial yield as frozen corn ear for all the hybrids was 54.2%. The industry has a similar value range of 48% to 54%. The ear size average was 21.57 cm, row number was 15, ear diameter 45.54 mm and the kernel corn deep was 8.57 mm. All these measurements were found not different from commercial values found for the industry. All corn samples evaluated showed good stability despites the frozen processing and storage. Hybrid 2038 ranked higher in quality.
Electric-field-induced association of colloidal particles
NASA Astrophysics Data System (ADS)
Fraden, Seth; Hurd, Alan J.; Meyer, Robert B.
1989-11-01
Dilute suspensions of micron diameter dielectric spheres confined to two dimensions are induced to aggregate linearly by application of an electric field. The growth of the average cluster size agrees well with the Smoluchowski equation, but the evolution of the measured cluster size distribution exhibits significant departures from theory at large times due to the formation of long linear clusters which effectively partition space into isolated one-dimensional strips.
NASA Astrophysics Data System (ADS)
Taheriniya, Shabnam; Parhizgar, Sara Sadat; Sari, Amir Hossein
2018-06-01
To study the alumina template pore size distribution as a function of Al thin film grain size distribution, porous alumina templates were prepared by anodizing sputtered aluminum thin films. To control the grain size the aluminum samples were sputtered with the rate of 0.5, 1 and 2 Å/s and the substrate temperature was either 25, 75 or 125 °C. All samples were anodized for 120 s in 1 M sulfuric acid solution kept at 1 °C while a 15 V potential was being applied. The standard deviation value for samples deposited at room temperature but with different rates is roughly 2 nm in both thin film and porous template form but it rises to approximately 4 nm with substrate temperature. Samples with the average grain size of 13, 14, 18.5 and 21 nm respectively produce alumina templates with an average pore size of 8.5, 10, 15 and 16 nm in that order which shows the average grain size limits the average pore diameter in the resulting template. Lateral correlation length and grain boundary effect are other factors that affect the pore formation process and pore size distribution by limiting the initial current density.
Arifin, Dian R; Palmer, Andre F
2003-01-01
In this study, we investigated the size distribution, encapsulation efficiency, and oxygen affinity of liposome-encapsulated tetrameric hemoglobin (LEHb) dispersions and correlated the data with the variation in extruder membrane pore size, ionic strength of the extrusion buffer, and hemoglobin (Hb) concentration. Asymmetric flow field-flow fractionation (AFFF) in series with multi-angle static light scattering (MASLS) was used to study the LEHb size distribution. We also introduced a novel method to measure the encapsulation efficiency using a differential interferometric refractive index (DIR) detector coupled to the AFFF-MASLS system. This technique was nondestructive toward the sample and easy to implement. LEHbs were prepared by extrusion using a lipid combination of dimyristoyl-phosphatidylcholine, cholesterol, and dimyristoyl-phosphatidylglycerol in a 10:9:1 molar ratio. Five initial Hb concentrations (50, 100, 150, 200, and 300 mg Hb per mL of buffer) extruded through five different membrane pore diameters (400, 200, 100, 80, and 50 nm) were studied. Phosphate buffered saline (PBS) and phosphate buffer (PB) both at pH 7.3 were used as extrusion buffers. Despite the variation, extrusion through 400-nm pore diameter membranes produced LEHbs smaller than the pore size, extrusion through 200-nm membranes produced LEHbs with diameters close to the pore diameter, and extrusion through 100-, 80-, and 50-nm membranes produced LEHbs larger than the pore sizes. We found that the choice of extrusion buffer had the greatest effect on the LEHb size distribution compared to either Hb concentration or extruder membrane pore size. Extrusion in PBS produced larger LEHbs and more monodisperse LEHb dispersions. However, LEHbs extruded in PB generally had higher Hb encapsulation efficiencies and lower methemoglobin (metHb) levels. The choice of extrusion buffer also affected how the encapsulation efficiency correlated with Hb concentration, extruder pore size, and the metHb level. The most optimum encapsulation efficiency and amount of Hb entrapped were achieved at the highest Hb concentration and the largest pore size for both extrusion buffers (62.38% and 187.14 mg Hb/mL of LEHb dispersion extruded in PBS, and 69.98% and 209.94 mg Hb/mL of LEHb dispersion extruded in PB). All LEHbs displayed good oxygen-carrying properties as indicated by their P(50) and cooperativity coefficients. LEHbs extruded in PB had an average P(50) of 23.04 mmHg and an average Hill number of 2.29, and those extruded in PBS had average values of 27.25 mmHg and 2.49. These oxygen-binding properties indicate that LEHbs possess strong potential as artificial blood substitutes. In addition, the metHb levels in PB-LEHb dispersions are significantly low even in the absence of antioxidants such as N-acetyl-L-cysteine.
NASA Astrophysics Data System (ADS)
Vahdatkhah, Parisa; Sadrnezhaad, Sayed Khatiboleslam
2015-12-01
Gold nanoparticles (AuNPs) of less than 50 nm diameter were electrodeposited from cyanide solution by pulsating electric current on modified copper and indium tin oxide (ITO) films coated on glass. Morphology, size, and composition of the deposited AuNPs were studied by X-ray photoelectron spectroscopy, atomic force microscopy, and field emission scanning electron microscopy. Effects of peak current density, pulse frequency, potassium iodide and cysteine on grain size, and morphology of the AuNPs were determined. Experiments showed that cathode current efficiency increases with the pulse frequency and the iodide ion. Size of the AuNPs increased with the current density. The number of nucleation sites was larger on ITO than on Cu layer; while the average diameter of the crystallites on ITO was smaller than on Cu layer.
CORRELATION OF FLORIDA SOIL-GAS PERMEABILITIES WITH GRAIN SIZE, MOISTURE, AND POROSITY
The report describes a new correlation or predicting gas permeabilities of undisturbed or recompacted soils from their average grain diameter (d), moisture saturation factor (m), and porosity (p). he correlation exhibits a geometric standard deviation (GSD) of only 1.27 between m...
Habitat patch size and nesting success of yellow-breasted chats
Dick E. Burhans; Frank R. Thompson III
1999-01-01
We measured vegetation at shrub patches used for nesting by Yellow-breasted Chats (Icteria virens) to evaluate the importance of nesting habitat patch features on nest predation, cowbird parasitism, and nest site selection. Logistic regression models indicated that nests in small patches (average diameter
Surface Modification and Damage of MeV-Energy Heavy Ion Irradiation on Gold Nanowires.
Cheng, Yaxiong; Yao, Huijun; Duan, Jinglai; Xu, Lijun; Zhai, Pengfei; Lyu, Shuangbao; Chen, Yonghui; Maaz, Khan; Mo, Dan; Sun, Youmei; Liu, Jie
2017-05-15
Gold nanowires with diameters ranging from 20 to 90 nm were fabricated by the electrochemical deposition technique in etched ion track polycarbonate templates and were then irradiated by Xe and Kr ions with the energy in MeV range. The surface modification of nanowires was studied by scanning electron microscopy (SEM) and transmission electron microscopy (TEM) characterizations. Different craters with and without protrusion on the gold nanowires were analyzed, and the two corresponding formation mechanisms, i.e., plastic flow and micro-explosion, were investigated. In addition, the sputtered gold nanoparticles caused by ion irradiation were studied and it was confirmed that the surface damage produced in gold nanowires was increased as the diameter of the nanowires decreased. It was also found that heavy ion irradiation can also create stacking fault tetrahedrons (SFTs) in gold nanowires and three different SFTs were confirmed in irradiated nanowires. A statistical analysis of the size distribution of SFTs in gold nanowires proved that the average size distribution of SFT was positively related to the nuclear stopping power of incident ions, i.e., the higher nuclear stopping power of incident ions could generate SFT with a larger average size in gold nanowires.
Surface Modification and Damage of MeV-Energy Heavy Ion Irradiation on Gold Nanowires
Cheng, Yaxiong; Yao, Huijun; Duan, Jinglai; Xu, Lijun; Zhai, Pengfei; Lyu, Shuangbao; Chen, Yonghui; Maaz, Khan; Mo, Dan; Sun, Youmei; Liu, Jie
2017-01-01
Gold nanowires with diameters ranging from 20 to 90 nm were fabricated by the electrochemical deposition technique in etched ion track polycarbonate templates and were then irradiated by Xe and Kr ions with the energy in MeV range. The surface modification of nanowires was studied by scanning electron microscopy (SEM) and transmission electron microscopy (TEM) characterizations. Different craters with and without protrusion on the gold nanowires were analyzed, and the two corresponding formation mechanisms, i.e., plastic flow and micro-explosion, were investigated. In addition, the sputtered gold nanoparticles caused by ion irradiation were studied and it was confirmed that the surface damage produced in gold nanowires was increased as the diameter of the nanowires decreased. It was also found that heavy ion irradiation can also create stacking fault tetrahedrons (SFTs) in gold nanowires and three different SFTs were confirmed in irradiated nanowires. A statistical analysis of the size distribution of SFTs in gold nanowires proved that the average size distribution of SFT was positively related to the nuclear stopping power of incident ions, i.e., the higher nuclear stopping power of incident ions could generate SFT with a larger average size in gold nanowires. PMID:28505116
Characterization of nebulized liposomal amikacin (Arikace) as a function of droplet size.
Li, Zhili; Zhang, Yanling; Wurtz, William; Lee, Jin K; Malinin, Vladimir S; Durwas-Krishnan, Sripriya; Meers, Paul; Perkins, Walter R
2008-09-01
The stress of nebulization has been shown to alter the properties of liposomal drugs. What has not been demonstrated is whether nebulized liposomes differ as a function of droplet size. Because droplet size influences lung deposition, liposomes with different properties could be deposited in different areas of the lung (e.g., central vs. peripheral). In this report, a liposomal amikacin formulation (Arikace, a registered trademark of Transave, Inc., Monmouth Junction, NJ) that is being developed as an inhaled treatment for gram negative infections was aerosolized with an eFlow (registered trademark of PARI, GmbH, Munich, Germany) nebulizer, reclaimed from the various stages of an Andersen cascade impactor (ACI) and analyzed for lipid-to-drug (L/D) (w/w) ratio, amikacin retention, and liposome size. For the nebulized solution, 99.7% of the total deposited drug was found on ACI stages 0 through 5, which have cutoff diameters of 9, 5.8, 4.7, 3.3, 2.1, and 1.1 microm, respectively. Properties were found to differ for drug reclaimed on stage 0 compared stages 1-5, which were not different from one another. For drug found on stages 1-5 (97% of total drug), the averages (n = 3) for L/D, percent encapsulated amikacin, and liposome mean diameter ranged from 0.59 to 0.68 (w/w), 71% to 75%, 248 to 282 nm, respectively. Drug found on stage 0 (2.8% of total drug) had an average L/D ratio of 0.51 and average liposome mean diameter of 375 nm. Examination of another batch of liposomal amikacin revealed no statistically significant differences between drug reclaimed on stages 0-5. Although a droplet size dependence was noted for one batch of Arikace aerosolized with the eFlow, the effect was considered to be inconsequential because the fraction in doubt represented nonrespirable particles >9 microm and accounted for <3% of the total deposited dose. The methodology applied here appears useful in evaluating aerosolized liposome systems. However, our results should not be assumed to apply to other liposome/drug compositions and nebulizers.
Determination of macular hole size in relation to individual variabilities of fovea morphology.
Shin, J Y; Chu, Y K; Hong, Y T; Kwon, O W; Byeon, S H
2015-08-01
To determine the preoperative anatomic factors in macular holes and their correlation to hole closure. Forty-six eyes with consecutive unilateral macular hole who had undergone surgery and followed up for at least 6 months were enrolled. Optical coherence tomography images and best-corrected visual acuity (BCVA) within 2 weeks prior to operation and 6 months after surgery were analyzed. The maximal hole dimension, foveal degeneration factors (inner nuclear layer cysts, outer segment (OS) shortening) and the widest foveolar floor size of the fellow eyes were measured. For overcoming preoperative individual variability of foveal morphology, an 'adjusted' hole size parameter (the ratio between the hole size and the fellow eye foveolar floor size) was used based on the fact that both eyes were morphologically symmetrical. Mean preoperative BCVA (logMAR) was 1.03±0.43 and the mean postoperative BCVA was 0.50±0.38 at 6 months. Preoperative BCVA is significantly associated with postoperative BCVA (P=0.0002). The average hole diameter was 448.9±196.8 μm and the average fellow eye foveolar floor size was 461.3±128.4 μm. There was a correlation between hole diameter and the size of the fellow eye foveolar floor (Pearson's coefficient=0.608, P<0.0001). The adjusted hole size parameter was 0.979±0.358 (0.761-2.336), which was a strong predictor for both anatomic (P=0.0281) and visual (P=0.0016) outcome. When determining the extent of preoperative hole size, we have to take into consideration the foveal morphologic variations among individuals. Hole size may be related to the original foveal shape, especially in relation to the centrifugal retraction of the foveal tissues.
Cho, Hyo-Min; Ding, Huanjun; Barber, William C; Iwanczyk, Jan S; Molloi, Sabee
2015-07-01
To investigate the feasibility of detecting breast microcalcification (μCa) with a dedicated breast computed tomography (CT) system based on energy-resolved photon-counting silicon (Si) strip detectors. The proposed photon-counting breast CT system and a bench-top prototype photon-counting breast CT system were simulated using a simulation package written in matlab to determine the smallest detectable μCa. A 14 cm diameter cylindrical phantom made of breast tissue with 20% glandularity was used to simulate an average-sized breast. Five different size groups of calcium carbonate grains, from 100 to 180 μm in diameter, were simulated inside of the cylindrical phantom. The images were acquired with a mean glandular dose (MGD) in the range of 0.7-8 mGy. A total of 400 images was used to perform a reader study. Another simulation study was performed using a 1.6 cm diameter cylindrical phantom to validate the experimental results from a bench-top prototype breast CT system. In the experimental study, a bench-top prototype CT system was constructed using a tungsten anode x-ray source and a single line 256-pixels Si strip photon-counting detector with a pixel pitch of 100 μm. Calcium carbonate grains, with diameter in the range of 105-215 μm, were embedded in a cylindrical plastic resin phantom to simulate μCas. The physical phantoms were imaged at 65 kVp with an entrance exposure in the range of 0.6-8 mGy. A total of 500 images was used to perform another reader study. The images were displayed in random order to three blinded observers, who were asked to give a 4-point confidence rating on each image regarding the presence of μCa. The μCa detectability for each image was evaluated by using the average area under the receiver operating characteristic curve (AUC) across the readers. The simulation results using a 14 cm diameter breast phantom showed that the proposed photon-counting breast CT system can achieve high detection accuracy with an average AUC greater than 0.89 ± 0.07 for μCas larger than 120 μm in diameter at a MGD of 3 mGy. The experimental results using a 1.6 cm diameter breast phantom showed that the prototype system can achieve an average AUC greater than 0.98 ± 0.01 for μCas larger than 140 μm in diameter using an entrance exposure of 1.2 mGy. The proposed photon-counting breast CT system based on a Si strip detector can potentially offer superior image quality to detect μCa with a lower dose level than a standard two-view mammography.
Fukuyama, Atsushi; Isoda, Haruo; Morita, Kento; Mori, Marika; Watanabe, Tomoya; Ishiguro, Kenta; Komori, Yoshiaki; Kosugi, Takafumi
2017-01-01
Introduction: We aim to elucidate the effect of spatial resolution of three-dimensional cine phase contrast magnetic resonance (3D cine PC MR) imaging on the accuracy of the blood flow analysis, and examine the optimal setting for spatial resolution using flow phantoms. Materials and Methods: The flow phantom has five types of acrylic pipes that represent human blood vessels (inner diameters: 15, 12, 9, 6, and 3 mm). The pipes were fixed with 1% agarose containing 0.025 mol/L gadolinium contrast agent. A blood-mimicking fluid with human blood property values was circulated through the pipes at a steady flow. Magnetic resonance (MR) images (three-directional phase images with speed information and magnitude images for information of shape) were acquired using the 3-Tesla MR system and receiving coil. Temporal changes in spatially-averaged velocity and maximum velocity were calculated using hemodynamic analysis software. We calculated the error rates of the flow velocities based on the volume flow rates measured with a flowmeter and examined measurement accuracy. Results: When the acrylic pipe was the size of the thoracicoabdominal or cervical artery and the ratio of pixel size for the pipe was set at 30% or lower, spatially-averaged velocity measurements were highly accurate. When the pixel size ratio was set at 10% or lower, maximum velocity could be measured with high accuracy. It was difficult to accurately measure maximum velocity of the 3-mm pipe, which was the size of an intracranial major artery, but the error for spatially-averaged velocity was 20% or less. Conclusions: Flow velocity measurement accuracy of 3D cine PC MR imaging for pipes with inner sizes equivalent to vessels in the cervical and thoracicoabdominal arteries is good. The flow velocity accuracy for the pipe with a 3-mm-diameter that is equivalent to major intracranial arteries is poor for maximum velocity, but it is relatively good for spatially-averaged velocity. PMID:28132996
A comparison study of size-specific dose estimate calculation methods.
Parikh, Roshni A; Wien, Michael A; Novak, Ronald D; Jordan, David W; Klahr, Paul; Soriano, Stephanie; Ciancibello, Leslie; Berlin, Sheila C
2018-01-01
The size-specific dose estimate (SSDE) has emerged as an improved metric for use by medical physicists and radiologists for estimating individual patient dose. Several methods of calculating SSDE have been described, ranging from patient thickness or attenuation-based (automated and manual) measurements to weight-based techniques. To compare the accuracy of thickness vs. weight measurement of body size to allow for the calculation of the size-specific dose estimate (SSDE) in pediatric body CT. We retrospectively identified 109 pediatric body CT examinations for SSDE calculation. We examined two automated methods measuring a series of level-specific diameters of the patient's body: method A used the effective diameter and method B used the water-equivalent diameter. Two manual methods measured patient diameter at two predetermined levels: the superior endplate of L2, where body width is typically most thin, and the superior femoral head or iliac crest (for scans that did not include the pelvis), where body width is typically most thick; method C averaged lateral measurements at these two levels from the CT projection scan, and method D averaged lateral and anteroposterior measurements at the same two levels from the axial CT images. Finally, we used body weight to characterize patient size, method E, and compared this with the various other measurement methods. Methods were compared across the entire population as well as by subgroup based on body width. Concordance correlation (ρ c ) between each of the SSDE calculation methods (methods A-E) was greater than 0.92 across the entire population, although the range was wider when analyzed by subgroup (0.42-0.99). When we compared each SSDE measurement method with CTDI vol, there was poor correlation, ρ c <0.77, with percentage differences between 20.8% and 51.0%. Automated computer algorithms are accurate and efficient in the calculation of SSDE. Manual methods based on patient thickness provide acceptable dose estimates for pediatric patients <30 cm in body width. Body weight provides a quick and practical method to identify conversion factors that can be used to estimate SSDE with reasonable accuracy in pediatric patients with body width ≥20 cm.
NASA Astrophysics Data System (ADS)
Liu, Fengxian; Bi, Xinhui; Zhang, Guohua; Peng, Long; Lian, Xiufeng; Lu, Huiying; Fu, Yuzhen; Wang, Xinming; Peng, Ping'an; Sheng, Guoying
2017-12-01
Size-segregated PM10 samples were collected in Guangzhou, China during autumn of 2014. Nine amines, including seven aliphatic amines and two heterocyclic amines, were detected using a gas chromatography-mass spectrometer after derivatization by benzenesulfonyl chloride. The total concentration of the nine amines (Ʃamines) was 79.6-140.9 ng m-3 in PM10. The most abundant species was methylamine (MA), which had a concentration of 29.2-70.1 ng m-3. MA, dimethylamine (DMA), diethylamine (DEA) and dibutylamine (DBA) were the predominant amines in the samples and accounted for approximately 80% of Ʃamines in each size segment. Two heterocyclic amines, pyrrolidine (PYR) and morpholine (MOR), were detected in all samples and had average concentrations of 1.14 ± 0.37 and 1.89 ± 0.64 ng m-3, respectively, in particles with aerodynamic diameters < 3 μm. More than 80% of Ʃamines were found in particles with diameters <1.5 μm, indicating that amines are mainly enriched in fine particles. All amines exhibited a bimodal distribution with a fine mode at 0.49-1.5 μm and a coarse mode at 7.2-10 μm. The maximum contributions of amines to particles (0.21%) and amines-N to water-soluble organic nitrogen (WSON) (3.1%) were found at the sizes < 0.49 μm. The maximum contribution of amines-C to water-soluble organic carbon (WSOC) was 1.6% over the size range of 0.95-1.5 μm. The molar ratio of Ʃamines to ammonium ranged from 0.0068 to 0.0107 in particles with diameters <1.5 μm, and the maximum ratio occurred in the smallest particles (diameter< 0.49 μm). The average dry deposition flux and velocity of Ʃamines in PM10 were 7.9 ± 1.6 μg m-2 d-1 and 0.084 ± 0.0021 cm s-1, respectively. The results of this study provide essential information on the contribution of amines to secondary organic aerosols and dry removal mechanisms in urban areas.
Kerr, Genevieve G; Nahrung, Helen F; Wiegand, Aaron; Kristoffersen, Joanna; Killen, Peter; Brown, Cameron; Macdonald, Joanne
2018-02-22
Silks from orb-weaving spiders are exceptionally tough, producing a model polymer for biomimetic fibre development. The mechanical properties of naturally spun silk threads from two species of Australian orb-weavers, Nephila pilipes and Nephila plumipes , were examined here in relation to overall thread diameter, the size and number of fibres within threads, and spider size. N. pilipes , the larger of the two species, had significantly tougher silk with higher strain capacity than its smaller congener, producing threads with average toughness of 150 MJ m -3 , despite thread diameter, mean fibre diameter and number of fibres per thread not differing significantly between the two species. Within N. pilipes , smaller silk fibres were produced by larger spiders, yielding tougher threads. In contrast, while spider size was correlated with thread diameter in N. plumipes , there were no clear patterns relating to silk toughness, which suggests that the differences in properties between the silk of the two species arise through differing molecular structure. Our results support previous studies that found that the mechanical properties of silk differ between distantly related spider species, and extends on that work to show that the mechanical and physical properties of silk from more closely related species can also differ remarkably. © 2018. Published by The Company of Biologists Ltd.
Particle sizing by weighted measurements of scattered light
NASA Technical Reports Server (NTRS)
Buchele, Donald R.
1988-01-01
A description is given of a measurement method, applicable to a poly-dispersion of particles, in which the intensity of scattered light at any angle is weighted by a factor proportional to that angle. Determination is then made of four angles at which the weighted intensity is four fractions of the maximum intensity. These yield four characteristic diameters, i.e., the diameters of the volume/area mean (D sub 32 the Sauter mean) and the volume/diameter mean (D sub 31); the diameters at cumulative volume fractions of 0.5 (D sub v0.5 the volume median) and 0.75 (D sub v0.75). They also yield the volume dispersion of diameters. Mie scattering computations show that an average diameter less than three micrometers cannot be accurately measured. The results are relatively insensitive to extraneous background light and to the nature of the diameter distribution. Also described is an experimental method of verifying the conclusions by using two microscopic slides coated with polystyrene microspheres to simulate the particles and the background.
SOME ENGINEERING PROPERTIES OF SHELLED AND KERNEL TEA (Camellia sinensis) SEEDS.
Altuntas, Ebubekir; Yildiz, Merve
2017-01-01
Camellia sinensis is the source of tea leaves and it is an economic crop now grown around the World. Tea seed oil has been used for cooking in China and other Asian countries for more than a thousand years. Tea is the most widely consumed beverages after water in the world. It is mainly produced in Asia, central Africa, and exported throughout the World. Some engineering properties (size dimensions, sphericity, volume, bulk and true densities, friction coefficient, colour characteristics and mechanical behaviour as rupture force of shelled and kernel tea ( Camellia sinensis ) seeds were determined in this study. This research was carried out for shelled and kernel tea seeds. The shelled tea seeds used in this study were obtained from East-Black Sea Tea Cooperative Institution in Rize city of Turkey. Shelled and kernel tea seeds were characterized as large and small sizes. The average geometric mean diameter and seed mass of the shelled tea seeds were 15.8 mm, 10.7 mm (large size); 1.47 g, 0.49 g (small size); while the average geometric mean diameter and seed mass of the kernel tea seeds were 11.8 mm, 8 mm for large size; 0.97 g, 0.31 g for small size, respectively. The sphericity, surface area and volume values were found to be higher in a larger size than small size for the shelled and kernel tea samples. The shelled tea seed's colour intensity (Chroma) were found between 59.31 and 64.22 for large size, while the kernel tea seed's chroma values were found between 56.04 68.34 for large size, respectively. The rupture force values of kernel tea seeds were higher than shelled tea seeds for the large size along X axis; whereas, the rupture force values of along X axis were higher than Y axis for large size of shelled tea seeds. The static coefficients of friction of shelled and kernel tea seeds for the large and small sizes higher values for rubber than the other friction surfaces. Some engineering properties, such as geometric mean diameter, sphericity, volume, bulk and true densities, the coefficient of friction, L*, a*, b* colour characteristics and rupture force of shelled and kernel tea ( Camellia sinensis ) seeds will serve to design the equipment used in postharvest treatments.
NASA Astrophysics Data System (ADS)
Yuksel, Heba; Davis, Christopher C.
2006-09-01
Intensity fluctuations at the receiver in free space optical (FSO) communication links lead to a received power variance that depends on the size of the receiver aperture. Increasing the size of the receiver aperture reduces the power variance. This effect of the receiver size on power variance is called aperture averaging. If there were no aperture size limitation at the receiver, then there would be no turbulence-induced scintillation. In practice, there is always a tradeoff between aperture size, transceiver weight, and potential transceiver agility for pointing, acquisition and tracking (PAT) of FSO communication links. We have developed a geometrical simulation model to predict the aperture averaging factor. This model is used to simulate the aperture averaging effect at given range by using a large number of rays, Gaussian as well as uniformly distributed, propagating through simulated turbulence into a circular receiver of varying aperture size. Turbulence is simulated by filling the propagation path with spherical bubbles of varying sizes and refractive index discontinuities statistically distributed according to various models. For each statistical representation of the atmosphere, the three-dimensional trajectory of each ray is analyzed using geometrical optics. These Monte Carlo techniques have proved capable of assessing the aperture averaging effect, in particular, the quantitative expected reduction in intensity fluctuations with increasing aperture diameter. In addition, beam wander results have demonstrated the range-cubed dependence of mean-squared beam wander. An effective turbulence parameter can also be determined by correlating beam wander behavior with the path length.
Bridgman growth of large-aperture yttrium calcium oxyborate crystal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Anhua, E-mail: wuanhua@mail.sic.ac.cn; Jiang, Linwen; Qian, Guoxing
2012-09-15
Highlights: ► YCOB is a novel non-linear optical crystal possessing good thermal, mechanical and nonlinear optical properties. ► Large size crystal growth is key technology question for YCOB crystal. ► YCOB crystals 3 in. in diameter were grown with modified vertical Bridgman method. ► It is a more effective growth method to obtain large size and high quality YCOB crystal. -- Abstract: Large-aperture yttrium calcium oxyborate YCa{sub 4}O(BO{sub 3}){sub 3} (YCOB) crystals with 3 in. in diameter were grown with modified vertical Bridgman method, and the large crystal plate (63 mm × 68 mm × 20 mm) was harvested formore » high-average power frequency conversion system. The crack, facet growth and spiral growth can be effectively controlled in the as-grown crystal, and Bridgman method displays more effective in obtain large size and high quality YCOB crystal plate than Czochralski technique.« less
Ishida, O; Maruyama, K; Sasaki, K; Iwatsuru, M
1999-11-10
We have examined the size dependence of extravasation and interstitial localization of polyethyleneglycol-coated liposomes (PEG-liposomes) in the solid tumor tissue by means of electron microscopic observation. Liposomes composed of distearoyl phosphatidylcholine, cholesterol and distearoylphosphatidylethanolamine derivative of polyethyleneglycol (PEG) were prepared in various size ranges. PEG-liposomes with an average diameter of 100-200 nm showed the most prolonged circulation time and the greatest tumor accumulation in all the solid tumors employed in this experiment. Although large PEG-liposomes with a diameter of 400 nm showed a short circulation time in normal mice, the results in splenectomized mice indicated that they do have an intrinsic prolonged circulation character in vivo. However, large PEG-liposomes could not extravasate into solid tumor tissue. These results indicate that the size of liposomes is critical for extravasation. The electron microscopic observations revealed the almost exclusive engulfment of extravasated liposomes by tumor-associated macrophages; very few were taken up by tumor cells.
Craters formed in mineral dust by hypervelocity microparticles.
NASA Technical Reports Server (NTRS)
Vedder, J. F.
1972-01-01
As a simulation of erosion processes on the lunar surface, impact craters were formed in dust targets by 2- to 5-micron-diameter polystyrene spheres with velocities between 2.5 and 12 km/sec. For weakly cohesive, thick targets of basalt dust with a maximum grain size comparable to the projectile diameter, the craters had an average projectile-to-diameter diameter ratio of 25, and the displaced mass was 3 orders of magnitude greater than the projectile mass. In a simulation of the effect of a dust covering on lunar rocks, a layer of cohesive, fine-grained basalt dust with a thickness nearly twice the projectile diameter protected a glass substrate from damage, but an area about 50 times the cross-sectional area of the projectile was cleared of all but a few grains. Impact damage was produced in glass under a thinner dust layer.
Measurement of Size-dependent Dynamic Shape Factors of Quartz Particles in Two Flow Regimes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alexander, Jennifer M.; Bell, David M.; Imre, D.
2016-08-02
Understanding and modeling the behavior of quartz dust particles, commonly found in the atmosphere, requires knowledge of many relevant particles properties, including particle shape. This study uses a single particle mass spectrometer, a differential mobility analyzer, and an aerosol particle mass analyzer to measure quartz aerosol particles mobility, aerodynamic, and volume equivalent diameters, mass, composition, effective density, and dynamic shape factor as a function of particle size, in both the free molecular and transition flow regimes. The results clearly demonstrate that dynamic shape factors can vary significantly as a function of particle size. For the quartz samples studied here, themore » dynamic shape factors increase with size, indicating that larger particles are significantly more aspherical than smaller particles. In addition, dynamic shape factors measured in the free-molecular (χv) and transition (χt) flow regimes can be significantly different, and these differences vary with the size of the quartz particles. For quartz, χv of small (d < 200 nm) particles is 1.25, while χv of larger particles (d ~ 440 nm) is 1.6, with a continuously increasing trend with particle size. In contrast χt, of small particles starts at 1.1 increasing slowly to 1.34 for 550 nm diameter particles. The multidimensional particle characterization approach used here goes beyond determination of average properties for each size, to provide additional information about how the particle dynamic shape factor may vary even for particles with the same mass and volume equivalent diameter.« less
Lumbar spinal canal MRI diameter is smaller in herniated disc cauda equina syndrome patients
Kruit, Mark C.; Peul, Wilco C.; Vleggeert-Lankamp, Carmen L. A.
2017-01-01
Introduction Correlation between magnetic resonance imaging (MRI) and clinical features in cauda equina syndrome (CES) is unknown; nor is known whether there are differences in MRI spinal canal size between lumbar herniated disc patients with CES versus lumbar herniated discs patients without CES, operated for sciatica. The aims of this study are 1) evaluating the association of MRI features with clinical presentation and outcome of CES and 2) comparing lumbar spinal canal diameters of lumbar herniated disc patients with CES versus lumbar herniated disc patients without CES, operated because of sciatica. Methods MRIs of CES patients were assessed for the following features: level of disc lesion, type (uni- or bilateral) and severity of caudal compression. Pre- and postoperative clinical features (micturition dysfunction, defecation dysfunction, altered sensation of the saddle area) were retrieved from the medical files. In addition, anteroposterior (AP) lumbar spinal canal diameters of CES patients were measured at MRI. AP diameters of lumbar herniated disc patients without CES, operated for sciatica, were measured for comparison. Results 48 CES patients were included. At MRI, bilateral compression was seen in 82%; complete caudal compression in 29%. MRI features were not associated with clinical presentation nor outcome. AP diameter was measured for 26 CES patients and for 31 lumbar herniated disc patients without CES, operated for sciatica. Comparison displayed a significant smaller AP diameter of the lumbar spinal canal in CES patients (largest p = 0.002). Compared to average diameters in literature, diameters of CES patients were significantly more often below average than that of the sciatica patients (largest p = 0.021). Conclusion This is the first study demonstrating differences in lumbar spinal canal size between lumbar herniated disc patients with CES and lumbar herniated disc patients without CES, operated for sciatica. This finding might imply that lumbar herniated disc patients with a relative small lumbar spinal canal might need to be approached differently in managing complaints of herniated disc. Since the number of studied patients is relatively small, further research should be conducted before clinical consequences are considered. PMID:29023556
NASA Astrophysics Data System (ADS)
Tonttila, J.; Romakkaniemi, S.; Kokkola, H.; Maalick, Z.; Korhonen, H.; Liqing, H.
2015-12-01
A new cloud-resolving model setup for studying aerosol-cloud interactions, with a special emphasis on partitioning and wet deposition of semi-volatile aerosol species, is presented. The model is based on modified versions of two well-established model components: the Large-Eddy Simulator (LES) UCLALES, and the sectional aerosol model SALSA, previously employed in the ECHAM climate model family. Implementation of the UCLALES-SALSA is described in detail. As the basis for this work, SALSA has been extended to include a sectional representation of the size distributions of cloud droplets and precipitation. Microphysical processes operating on clouds and precipitation have also been added. Given our main motivation, the cloud droplet size bins are defined according to the dry particle diameter. The droplet wet diameter is solved dynamically through condensation equations, but represents an average droplet diameter inside each size bin. This approach allows for accurate tracking of the aerosol properties inside clouds, but minimizes the computational cost. Since the actual cloud droplet diameter is not fully resolved inside the size bins, processes such as precipitation formation rely on parameterizations. For realistic growth of drizzle drops to rain, which is critical for the aerosol wet deposition, the precipitation size bins are defined according to the actual drop size. With these additions, the implementation of the SALSA model replaces most of the microphysical and thermodynamical components within the LES. The cloud properties and aerosol-cloud interactions simulated by the model are analysed and evaluated against detailed cloud microphysical boxmodel results and in-situ aerosol-cloud interaction observations from the Puijo measurement station in Kuopio, Finland. The ability of the model to reproduce the impacts of wet deposition on the aerosol population is demonstrated.
Historical early stem development of northern white-cedar (Thuja occidentalis L.) in Maine
Philip V. Hofmeyer; Laura S. Kenefic; Robert S. Seymour
2010-01-01
We used stem analysis to quantify early height and diameter growth rates of 80 northern white-cedar trees (17.4-55.0 cm dbh) harvested in 2005 and 2006 in central and northern Maine. It took an average of 42 years (range, 9-86 years) for sampled trees to grow from stump height to sapling size, 96 years to grow to pole size (range, 28-171), 140 years to grow to...
Doughty, Michael J
2017-07-01
The aim was to assess differences in eyeball mass, corneal diameter and central corneal thickness in slaughterhouse-procured ovine eyes. Over a 12-year period, measurements of eye globe mass, horizontal corneal diameter and central corneal thickness were routinely undertaken within two hours post-mortem. Only eyes free of obvious mechanical damage or disease were used. From measurements on 736 quality-selected and trimmed eyes, globe wet mass ranged from 10.4 to 25.2 g, horizontal corneal diameter from 19.0 to 26.5 mm and central corneal thickness measured by ultrasonic pachymetry from 0.543 to 0.836 mm (with an overall average of 690 ± 0.056 mm). The ocular globe mass was strongly correlated to horizontal corneal diameter (r 2 = 0.829). Central corneal thickness correlated with globe mass (r = 0.543) and to horizontal corneal diameter (r = 0.402). Based on the different anatomical measurements, a lamb's eye would be expected to have a thinner cornea (average 0.640 mm) than that of an adult outbred ewe (average 0.730 mm). In freshly procured eyes showing signs of slight corneal oedema, central corneal thickness was greater (average 0.856 ± 0.052 mm) and up to 24 hours of cold storage resulted in predictable increases in central corneal thickness of six to 24 per cent, especially in eyes showing signs of corneal oedema before storage. Based on the correlations obtained, differences in ovine eyes can be attributed to growth-related differences in the animals and thus, indirectly to their expected ages. A simple measure of the horizontal corneal diameter in ovine eyes used for laboratory studies would be a useful indicator in reporting these studies. © 2016 Optometry Australia.
The influence of wildfires on aerosol size distributions in rural areas.
Alonso-Blanco, E; Calvo, A I; Fraile, R; Castro, A
2012-01-01
The number of particles and their size distributions were measured in a rural area, during the summer, using a PCASP-X. The aim was to study the influence of wildfires on particle size distributions. The comparative studies carried out reveal an average increase of around ten times in the number of particles in the fine mode, especially in sizes between 0.10 and 0.14 μm, where the increase is of nearly 20 times. An analysis carried out at three different points in time--before, during, and after the passing of the smoke plume from the wildfires--shows that the mean geometric diameter of the fine mode in the measurements affected by the fire is smaller than the one obtained in the measurements carried out immediately before and after (0.14 μm) and presents average values of 0.11 μm.
The Influence of Wildfires on Aerosol Size Distributions in Rural Areas
Alonso-Blanco, E.; Calvo, A. I.; Fraile, R.; Castro, A.
2012-01-01
The number of particles and their size distributions were measured in a rural area, during the summer, using a PCASP-X. The aim was to study the influence of wildfires on particle size distributions. The comparative studies carried out reveal an average increase of around ten times in the number of particles in the fine mode, especially in sizes between 0.10 and 0.14 μm, where the increase is of nearly 20 times. An analysis carried out at three different points in time—before, during, and after the passing of the smoke plume from the wildfires—shows that the mean geometric diameter of the fine mode in the measurements affected by the fire is smaller than the one obtained in the measurements carried out immediately before and after (0.14 μm) and presents average values of 0.11 μm. PMID:22629191
Uneven distribution of inorganic pollutants in marine air originating from ocean-going ships.
Bencs, László; Horemans, Benjamin; Buczyńska, Anna Jolanta; Van Grieken, René
2017-03-01
The distribution of mass, water-soluble inorganic salts and mineral elements of size-segregated aerosols (PM 1 , PM 2.5-1 and PM 10-2.5 ), precursor gaseous pollutants, black carbon, and nanoparticles (10-300 nm size range) at the Southern Bight of the North Sea has been studied. The concentrations of air pollutants peaked over shipping lanes, open-water anchorage areas and frequently navigated waters, due to the presence of mobile emission sources. A considerable decrease in air pollutant levels was seen when diverting from these marine areas towards remote or coastal banks. These findings showed the rapid dispersion of pollutants in the marine air. The nano-aerosol count, originating from ocean-going ships, peaked at lower average aerodynamic diameters (e.g., ≈28 nm) than those, observed from low-displacement vessels (45-50 nm, e.g., for fishing boats). The average diameter of nano-PM depended also on weather conditions, e.g., it was higher (≈50 nm) in air of higher humidity. Copyright © 2016 Elsevier Ltd. All rights reserved.
Synthesis of mono-dispersed nanofluids using solution plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heo, Yong Kang, E-mail: yk@rd.numse.nagoya-u.ac.jp; Bratescu, Maria Antoaneta, E-mail: maria@rd.numse.nagoya-u.ac.jp; Knowledge Hub Aichi, Yakusa-cho, Nagakute-ku, Toyota
2014-07-14
Small-sized and well-dispersed gold nanoparticles (NPs) for nanofluidics have been synthesized by electrical discharge in liquid environment using termed solution plasma processing (SPP). Electrons and the hydrogen radicals are reducing the gold ions to the neutral form in plasma gas phase and liquid phase, respectively. The gold NPs have the smallest diameter of 4.9 nm when the solution temperature was kept at 20 °C. Nucleation and growth theory describe the evolution of the NP diameter right after the reduction reaction in function of the system temperature, NP surface energy, dispersion energy barrier, and nucleation rate. Negative charges on the NPs surface duringmore » and after SPP generate repulsive forces among the NPs avoiding their agglomeration in solution. Increasing the average energy in the SPP determines a decrease of the zeta potential and an increase of the NPs diameter. An important enhancement of the thermal conductivity of 9.4% was measured for the synthesized nanofluids containing NPs with the smallest size.« less
Efficacy of spatial averaging of infrasonic pressure in varying wind speeds.
DeWolf, Scott; Walker, Kristoffer T; Zumberge, Mark A; Denis, Stephane
2013-06-01
Wind noise reduction (WNR) is important in the measurement of infrasound. Spatial averaging theory led to the development of rosette pipe arrays. The efficacy of rosettes decreases with increasing wind speed and only provides a maximum of ~20 dB WNR due to a maximum size limitation. An Optical Fiber Infrasound Sensor (OFIS) reduces wind noise by instantaneously averaging infrasound along the sensor's length. In this study two experiments quantify the WNR achieved by rosettes and OFISs of various sizes and configurations. Specifically, it is shown that the WNR for a circular OFIS 18 m in diameter is the same as a collocated 32-inlet pipe array of the same diameter. However, linear OFISs ranging in length from 30 to 270 m provide a WNR of up to ~30 dB in winds up to 5 m/s. The measured WNR is a logarithmic function of the OFIS length and depends on the orientation of the OFIS with respect to wind direction. OFISs oriented parallel to the wind direction achieve ~4 dB greater WNR than those oriented perpendicular to the wind. Analytical models for the rosette and OFIS are developed that predict the general observed relationships between wind noise reduction, frequency, and wind speed.
[Spectrum simulation based on data derived from red tide].
Liu, Zhen-Yu; Cui, Ting-Wei; Yue, Jie; Jiang, Tao; Cao, Wen-Xi; Ma, Yi
2011-11-01
The present paper utilizes the absorption data of red tide water measured during the growing and dying course to retrieve imaginary part of the index of refraction based on Mie theory, carries out the simulation and analysis of average absorption efficiency factors, average backscattering efficiency factors and scattering phase function. The analysis of the simulation shows that Mie theory can be used to reproduce the absorption property of Chaetoceros socialis with an average error of 11%; the average backscattering efficiency factors depend on the value of absorption whose maximum value corresponds to the wavelength range from 400 to 700 nanometer; the average backscattering efficiency factors showed a maximum value on 17th with a low value during the outbreak of red tide and the minimum on 21th; the total scattering, weakly depending on the absorption, is proportional to the size parameters which represent the relative size of cell diameter with respect to the wavelength, while the angle scattering intensity is inversely proportional to wavelength.
Luo, Wanxian; Wen, Ge; Yang, Li; Tang, Jiao; Wang, Jianguo; Wang, Jihui; Zhang, Shiyu; Zhang, Li; Ma, Fei; Xiao, Liling; Wang, Ying; Li, Yingjia
2017-01-01
In this study, we investigated the potential of a dual-targeted pH-sensitive doxorubicin prodrug-microbubble complex (DPMC) in ultrasound (US)-assisted antitumor therapy. The doxorubicin prodrug (DP) consists of a succinylated-heparin carrier conjugated with doxorubicin (DOX) via hydrazone linkage and decorated with dual targeting ligands, folate and cRGD peptide. Combination of microbubble (MB) and DP, generated via avidin-biotin binding, promoted intracellular accumulation and improved therapeutic efficiency assisted by US cavitation and sonoporation. Aggregates of prepared DP were observed with an inhomogeneous size distribution (average diameters: 149.6±29.8 nm and 1036.2±38.8 nm, PDI: 1.0) while DPMC exhibited a uniform distribution (average diameter: 5.804±2.1 μm), facilitating its usage for drug delivery. Notably, upon US exposure, DPMC was disrupted and aggregated DP dispersed into homogeneous small-sized nanoparticles (average diameter: 128.6±42.3 nm, PDI: 0.21). DPMC could target to angiogenic endothelial cells in tumor region via αvβ3-mediated recognition and subsequently facilitate its specific binding to tumor cells mediated via recognition of folate receptor (FR) after US exposure. In vitro experiments showed higher tumor specificity and killing ability of DPMC with US than free DOX and DP for breast cancer MCF-7 cells. Furthermore, significant accumulation and specificity for tumor tissues of DPMC with US were detected using in vivo fluorescence and ultrasound molecular imaging, indicating its potential to integrate tumor imaging and therapy. In particular, through inducing apoptosis, inhibiting cell proliferation and antagonizing angiogenesis, DPMC with US produced higher tumor inhibition rates than DOX or DPMC without US in MCF-7 xenograft tumor-bearing mice while inducing no obvious body weight loss. Our strategy provides an effective platform for the delivery of large-sized or aggregated particles to tumor sites, thereby extending their therapeutic applications in vivo. PMID:28255342
Manipulation of Microbubble Clusters Using Focused Ultrasound
NASA Astrophysics Data System (ADS)
Matsuzaki, Hironobu; Osaki, Taichi; Kawaguchi, Kei; Unga, Johan; Ichiyanagi, Mitsuhisa; Azuma, Takashi; Suzuki, Ryo; Maruyama, Kazuo; Takagi, Shu
2017-11-01
In recent years, microbubbles (MBs) are expected to be utilized for the ultrasound drug delivery system (DDS). For the MB-DDS, it is important to establish a method of controlling bubbles and bubble clusters using ultrasound field. The objective of this study is to clarify behaviors of bubble clusters with various physical conditions. MBs in the ultrasound field are subjected to the primary Bjerknes force. The force traps MBs at the focal region of the focused ultrasound field. The trapped MBs form a bubble cluster at the region. A bubble cluster continues growing with absorbing surrounding bubbles until it reaches a maximum size beyond which it disappears from the focal region. In the present study, two kinds of MBs are used for the experiment. One is Sonazoid with average diameter of 2.6 um and resonant frequency of 5 MHz. The other is developed by Teikyo Univ., with average diameter of 1.5 um and presumed resonant frequency of 4 MHz. The bubble cluster's behaviors are analyzed using the high-speed camera. Sonazoid clusters have larger critical size than the other in every frequency, and its cluster size is inversely proportional to the ultrasound frequency, while Teikyo-bubble clusters have different tendency. These results are discussed in the presentation.
Tailoring sub-micron PLGA particle release profiles via centrifugal fractioning
Dutta, Dipankar; Salifu, Mariama; Sirianni, Rachael W.; Stabenfeldt, Sarah E.
2016-01-01
Poly(D,L-lactic-co-glycolic) acid (PLGA)-based submicron particles are uniquely posed to overcome limitations of conventional drug delivery systems. However, tailoring cargo/payload release profiles from PLGA micro/nanoparticles typically requires optimization of the multi-parameter formulation, where small changes may cause drastic shifts in the resulting release profiles. In this study, we aimed to establish whether refining the average diameter of submicron particle populations after formulation alters protein release profiles. PLGA particles were first produced via double emulsion-solvent evaporation method to encapsulate bovine serum albumin. Particles were then subjected to centrifugal fractioning protocols varying in both spin time and force to determine encapsulation efficiency and release profile of differently sized populations that originated from a single batch. We found the average particle diameter was related to marked alterations in encapsulation efficiencies (range: 36.4–49.4%), burst release (range: 15.8–49.1%), and time for total cargo release (range: 38–78 days). Our data corroborate previous reports relating PLGA particle size with such release characteristics, however, this is the first study, to our knowledge, to directly compare particle population size while holding all formulation parameters constant. In summary, centrifugal fractioning to selectively control the population distribution of sub-micron PLGA particles represents a feasible tool to tailor release characteristics. PMID:26517011
Wang, Yusen; Wang, Xiaoxia; Feng, Xiaolan; Ye, Xiao; Fu, Jie
2018-01-01
Layered double hydroxides (LDHs) have been widely used as an important subset of solid base catalysts. However, developing low-cost, small-sized LDH nanoparticles with enhanced surface catalytic sites remains a challenge. In this work, silica aerogel (SA)-supported, small-sized Mg–Al LDH nanosheets were successfully prepared by one-pot coprecipitation of Mg and Al ions in an alkaline suspension of crushed silica aerogel. The supported LDH nanosheets were uniformly dispersed in the SA substrate with the smallest average radial diameter of 19.2 nm and the thinnest average thickness of 3.2 nm, both dimensions being significantly less than those of the vast majority of LDH nanoparticles reported. The SA/LDH composites also showed large pore volume (up to 1.3 cm3·g) and pore diameter (>9 nm), and therefore allow efficient access of reactants to the edge catalytic sites of LDH nanosheets. In a base-catalyzed Henry reaction of benzaldehyde with nitromethane, the SA/LDH catalysts showed high reactant conversions and favorable stability in 6 successive cycles of reactions. The low cost of the SA carrier and LDH precursors, easy preparation method, and excellent catalytic properties make these SA/LDH composites a competitive example of solid-base catalysts. PMID:29462941
Wang, Lijun; Wang, Yusen; Wang, Xiaoxia; Feng, Xiaolan; Ye, Xiao; Fu, Jie
2018-02-16
Layered double hydroxides (LDHs) have been widely used as an important subset of solid base catalysts. However, developing low-cost, small-sized LDH nanoparticles with enhanced surface catalytic sites remains a challenge. In this work, silica aerogel (SA)-supported, small-sized Mg-Al LDH nanosheets were successfully prepared by one-pot coprecipitation of Mg and Al ions in an alkaline suspension of crushed silica aerogel. The supported LDH nanosheets were uniformly dispersed in the SA substrate with the smallest average radial diameter of 19.2 nm and the thinnest average thickness of 3.2 nm, both dimensions being significantly less than those of the vast majority of LDH nanoparticles reported. The SA/LDH composites also showed large pore volume (up to 1.3 cm3·g) and pore diameter (>9 nm), and therefore allow efficient access of reactants to the edge catalytic sites of LDH nanosheets. In a base-catalyzed Henry reaction of benzaldehyde with nitromethane, the SA/LDH catalysts showed high reactant conversions and favorable stability in 6 successive cycles of reactions. The low cost of the SA carrier and LDH precursors, easy preparation method, and excellent catalytic properties make these SA/LDH composites a competitive example of solid-base catalysts.
Harvesting, predation and competition effects on a red coral population
NASA Astrophysics Data System (ADS)
Abbiati, M.; Buffoni, G.; Caforio, G.; Di Cola, G.; Santangelo, G.
A Corallium rubrum population, dwelling in the Ligurian Sea, has been under observation since 1987. Biometric descriptors of colonies (base diameter, weight, number of polyps, number of growth rings) have been recorded and correlated. The population size structure was obtained by distributing the colonies into diameter classes, each size class representing the average annual increment of diameter growth. The population was divided into ten classes, including a recruitment class. This size structure showed a fairly regular trend in the first four classes. The irregularity of survival in the older classes agreed with field observations on harvesting and predation. Demographic parameters such as survival, growth plasticity and natality coefficients were estimated from the experimental data. On this basis a discrete nonlinear model was implemented. The model is based on a kind of density-dependent Leslie matrix, where the feedback term only occurs in survival of the first class; the recruitment function is assumed to be dependent on the total biomass and related to inhibiting effects due to competitive interactions. Stability analysis was applied to steady-state solutions. Numerical simulations of population evolution were carried out under different conditions. The dynamics of settlement and the effects of disturbances such as harvesting, predation and environmental variability were studied.
Simpanya, M. Francis; Ansari, Rafat R.; Suh, Kwang I.; Leverenz, Victor R.; Giblin, Frank J.
2006-01-01
Purpose The role of oxygen in the formation of lens high-molecular-weight (HMW) protein aggregates during the development of human nuclear cataract is not well understood. The purpose of this study was to investigate lens crystallin aggregate formation in hyperbaric oxygen (HBO)–treated guinea pigs by using in vivo and in vitro methods. Methods Guinea pigs were treated three times weekly for 7 months with HBO, and lens crystallin aggregation was investigated in vivo with the use of dynamic light-scattering (DLS) and in vitro by HPLC analysis of water-insoluble (WI) proteins. DLS measurements were made every 0.1 mm across the 4.5- to 5.0-mm optical axis of the guinea pig lens. Results The average apparent diameter of proteins in the nucleus (the central region) of lenses of HBO-treated animals was nearly twice that of the control animals (P < 0.001). Size distribution analysis conducted at one selected point in the nucleus and cortex (the outer periphery of the lens) after dividing the proteins into small-diameter and large-diameter groups, showed in the O2-treated nucleus a threefold increase in intensity (P < 0.001) and a doubling in apparent size (P = 0.03) of large-diameter aggregate proteins, compared with the same control group. No significant changes in apparent protein diameter were detected in the O2-treated cortex, compared with the control. The average diameter of protein aggregates at the single selected location in the O2-treated nucleus was estimated to be 150 nm, a size capable of scattering light and similar to the size of aggregates found in human nuclear cataracts. HPLC analysis indicated that one half of the experimental nuclear WI protein fraction (that had been dissolved in guanidine) consisted of disulfide cross-linked 150- to 1000-kDa aggregates, not present in the control. HPLC-isolated aggregates contained αA-, β-, γ-, and ζ-crystallins, but not αB-crystallin, which is devoid of −SH groups and thus does not participate in disulfide cross-linking. All ζ-crystallin present in the nuclear WI fraction appeared to be there as a result of disulfide cross-linking. Conclusions The results indicate that molecular oxygen in vivo can induce the cross-linking of guinea pig lens nuclear crystallins into large disulfide-bonded aggregates capable of scattering light. A similar process may be involved in the formation of human nuclear cataract. PMID:16303961
Sletnes, M; Maria, J; Grande, T; Lindgren, M; Einarsrud, M-A
2014-02-07
Blue-green luminescent octoxy capped Si nanoparticles were synthesized via homogeneous reduction of SiCl4 with the crown ether alkalide K(+)(15-crown-5)2K(-) in tetrahydrofuran. The Si nanoparticles were characterized with respect to size, crystal structure, morphology, surface termination, optical properties and stability. Si diamond structure nanoparticles with narrow size distributions, and average diameters ranging from 3 to 7 nm were obtained. A finite-size effect on the lattice dimensions was observed, in the form of an expansion of the [220] lattice planes of smaller Si nanoparticles. The concentration of SiCl4 was found to be the most important parameter governing the particle size and size distribution. The octoxy capped particles were stable under an ambient atmosphere for at least one month, but exposure to water made them prone to oxidation. An average radiative recombination lifetime of 8.8 ns was measured for the blue-green luminescence. The luminescence appears to originate from surface defects, rather than from quantum confinement.
Preparation and Characterization of Nano-CL-20 Explosive
NASA Astrophysics Data System (ADS)
Bayat, Yadollah; Zeynali, Vida
2011-10-01
Nano-CL-20 was prepared via precipitative crystallization by spraying a solution of CL-20 in a solvent (ethyl acetate) into a nonsolvent (isooctane). Scanning electron microscopy (SEM) and X-ray powder diffraction (XRD) were used to characterize the appearance and the size of the particles. The results revealed that nano-CL-20 particles have the shape of spheres or ellipsoids with an average size of 95 nm. Due to their small diameter and high surface energy, the particles tended to agglomerate. Impact sensitivity of nanosize CL-20 was decreased in comparison to micrometer-size CL-20.
Pulsed beam of extremely large helium droplets
NASA Astrophysics Data System (ADS)
Kuma, Susumu; Azuma, Toshiyuki
2017-12-01
We generated a pulsed helium droplet beam with average droplet diameters of up to 2 μ m using a solenoid pulsed valve operated at temperatures as low as 7 K. The droplet diameter was controllable over two orders of magnitude, or six orders of the number of atoms per droplet, by lowering the valve temperature from 21 to 7 K. A sudden droplet size change attributed to the so-called ;supercritical expansion; was firstly observed in pulsed mode, which is necessary to obtain the micrometer-scale droplets. This beam source is beneficial for experiments that require extremely large helium droplets in intense, pulsed form.
Hajjaji, A; Elabidi, M; Trabelsi, K; Assadi, A A; Bessais, B; Rtimi, S
2018-06-05
This study investigates the effect of the diameter of TiO 2 nanotubes and silver decorated nanotubes on optical properties and photocatalytic inactivation of Escherichia coli under visible light. The TiO 2 nanotubes (TiO 2 -NTs) were prepared using the electrochemical method varying the anodization potential starting from 20 V until 70 V. The Ag nanoparticles were carried out using the photoreduction process under the same experimental conditions. The diameter size was determined using the scanning electronic microscopy (SEM). TiO 2 -NTs diameter reached ∼100 nm at 70 V. Transmission electronic microscopy (TEM) imaging confirmed the TiO 2 -NTs surface decoration by silver nanoparticles. The Ag-NPs average size was found to be equal to 8 nm. The X-Ray diffraction (XRD) analysis confirm that all TiO 2 -NTs crystallize in the anatase phases regardless the used anodization potential. The decrease of the photoluminescence (PL) intensity of Ag NPs decorated TiO 2 -NTs indicates the decrease of the specific area when the nanotubes diameter increases. The UV-vis absorbance show that the absorption edges was bleu shifted with the increasing of nanotubes diameter, which can be explained by the increase of the crystallites average size. The bacterial adhesion and inactivation tests were carried in the dark and under light. Bacteria were seen to adhere on TiO 2 -NTs in the dark; however, under light the bacteria were killed before they establish a strong contact with the TiO 2 -NTs and Ag/TiO 2 -NTs surfaces. Bacterial inactivation kinetics were faster when the anodizing potential of the NTs-preparation increases. A total bacterial inactivation was obtained on ∼100 nm nanotubes diameter within 90 min. This result was attributed to the enhancement of the TNTs crystallinity leading to reduced surface defects. Redox catalysis was seen to occur under light on the TiO 2 -NTs and Ag/TiO 2 -NTs. the photo-induced antibacterial activity on the AgO/Ag 2 O decorated TiO 2 -NTs was attributed to the interfacial charge transfer mechanism (IFCT). Copyright © 2018 Elsevier B.V. All rights reserved.
Sussman, Daniel A; Deshpande, Amar R; Shankar, Uday; Barkin, Jodie A; Medina, Ana Maria; Poppiti, Robert J; Cubeddu, Luigi X; Barkin, Jamie S
2016-08-01
Obtaining quality endoscopic biopsy specimens is vital in making successful histological diagnoses. The influence of forceps cup shape and size on quality of biopsy specimens is unclear. To identify whether oval cup or two different serrated jaw biopsy forceps could obtain specimens of superior size. Secondary endpoints were tissue adequacy, depth of tissue acquisition, and crush artifact. A single-center, prospective, pathologist-masked, randomized controlled trial was performed. In total 136 patients with a clinical indication for esophagogastroduodenoscopy with biopsy were randomized to receive serial biopsies with a large-capacity serrated forceps with jaw diameter 2.2 mm (SER1) and either a large-capacity oval forceps with jaw diameter 2.4 mm (OVL) or large-capacity serrated biopsy forceps with jaw diameter 2.4 mm (SER2) in two parallel groups. SER2 provided significantly larger specimens than did the other forceps (SER2 3.26 ± 1.09 vs. SER1 2.92 ± 0.88 vs. OVL 2.92 ± 0.76; p = 0.026), with an average size difference of 0.34 mm greater with SER2 compared to SER1 and OVL. OVL provided significantly deeper biopsies compared to SER1 and SER2 (p = 0.02), with 31 % of OVL biopsies reaching the submucosa. SER2 had significantly less crush artifact than SER1 and OVL (p < 0.0001). Serrated forceps provided larger samples compared to oval jaw forceps of the same size, with SER2 providing the largest specimen size. Oval cup forceps had deeper penetration of epithelium, while the larger jaw diameter serrated jaw forceps had less crush artifact. All three forceps provided specimens adequate for diagnostic purposes.
Zheng, Tianyu; Bott, Steven; Huo, Qun
2016-08-24
Gold nanoparticles (AuNPs) have found broad applications in chemical and biological sensing, catalysis, biomolecular imaging, in vitro diagnostics, cancer therapy, and many other areas. Dynamic light scattering (DLS) is an analytical tool used routinely for nanoparticle size measurement and analysis. Due to its relatively low cost and ease of operation in comparison to other more sophisticated techniques, DLS is the primary choice of instrumentation for analyzing the size and size distribution of nanoparticle suspensions. However, many DLS users are unfamiliar with the principles behind the DLS measurement and are unware of some of the intrinsic limitations as well as the unique capabilities of this technique. The lack of sufficient understanding of DLS often leads to inappropriate experimental design and misinterpretation of the data. In this study, we performed DLS analyses on a series of citrate-stabilized AuNPs with diameters ranging from 10 to 100 nm. Our study shows that the measured hydrodynamic diameters of the AuNPs can vary significantly with concentration and incident laser power. The scattered light intensity of the AuNPs has a nearly sixth order power law increase with diameter, and the enormous scattered light intensity of AuNPs with diameters around or exceeding 80 nm causes a substantial multiple scattering effect in conventional DLS instruments. The effect leads to significant errors in the reported average hydrodynamic diameter of the AuNPs when the measurements are analyzed in the conventional way, without accounting for the multiple scattering. We present here some useful methods to obtain the accurate hydrodynamic size of the AuNPs using DLS. We also demonstrate and explain an extremely powerful aspect of DLS-its exceptional sensitivity in detecting gold nanoparticle aggregate formation, and the use of this unique capability for chemical and biological sensing applications.
Influence of rainfall microstructure on rainfall interception
NASA Astrophysics Data System (ADS)
Zabret, Katarina; Rakovec, Jože; Mikoš, Matjaž; Šraj, Mojca
2016-04-01
Rainfall interception is part of the hydrological cycle. Precipitation, which hits vegetation, is retained on the leaves and branches, from which it eventually evaporates into the atmosphere (interception) or reaches the ground by dripping from the canopy, falling through the gaps (throughfall) and running down the stems (stemflow). The process is influenced by various meteorological and vegetation parameters. Often neglected meteorological parameter influencing rainfall interception is also rainfall microstructure. Rain is a discrete process consisting of various numbers of individual raindrops with different sizes and velocities. This properties describe rainfall microstructure which is often neglected in hydrological analysis and replaced with rainfall intensity. Throughfall, stemflow and rainfall microstructure have been measured since the beginning of the year 2014 under two tree species (Betula pendula and Pinus nigra) on a study plot in Ljubljana, Slovenia. The preliminary analysis of the influence of rainfall microstructure on rainfall interception has been conducted using three events with different characteristics measured in May 2014. Event A is quite short with low rainfall amount and moderate rainfall intensity, whereas events B and C have similar length but low and high intensities, respectively. Event A was observed on the 1st of May 2014. It was 22 minutes long and delivered 1.2 mm of rainfall. The average rainfall intensity was equal to 3.27 mm/h. The event consisted of 1,350 rain drops with average diameter of 1.517 mm and average velocity of 5.110 m/s. Both Betula pendula and Pinus nigra intercepted similar amount of rainfall, 68 % and 69 %, respectively. Event B was observed in the night from the 7th to 8th of May 2014, it was 16 hours and 18 minutes long, and delivered 4.2 mm of rainfall with average intensity of 0.97 mm/h. There were 39,108 raindrops detected with average diameter of 0.858 mm and average velocity of 3.855 m/s. Betula pendula (23 %) has intercepted significantly less rainfall than Pinus nigra (85%). Event C was also observed in the night time between 11th and 12th of May 2014, it lasted 4 hours and 12 minutes and delivered 34.6 mm of rainfall with an average intensity equal to 8.24 mm/h. During the event 147,236 raindrops with average diameter of 1.020 mm and average velocity of 4.078 m/s were detected. Betula pendula has intercepted only 6 % of rainfall whereas Pinus nigra intercepted majority of rainfall, namely 85 %. In case of B. pendula rainfall interception is increasing with higher velocity whereas it is lower for medium diameters than for smaller or larger diameters. Rainfall interception under P. nigra is decreasing with higher velocities and behaving similar as under B. pendula for different diameters but with less obvious difference between diameter classes. We will continue with the measurements and further analysis of several rainfall events will be prepared.
Dielectrophoretic immobilisation of nanoparticles as isolated singles in regular arrays
NASA Astrophysics Data System (ADS)
Knigge, Xenia; Wenger, Christian; Bier, Frank F.; Hölzel, Ralph
2018-02-01
We demonstrate the immobilisation of polystyrene nanoparticles on vertical nano-electrodes by means of dielectrophoresis. The electrodes have diameters of 500 nm or 50 nm, respectively, and are arranged in arrays of several thousand electrodes, allowing many thousands of experiments in parallel. At a frequency of 15 kHz, which is found favourable for polystyrene, several occupation patterns are observed, and both temporary and permanent immobilisation is achieved. In addition, a histogram method is applied, which allows to determine the number of particles occupying the electrodes. These results are validated with scanning electron microscopy images. Immobilising exactly one particle at each electrode tip is achieved for electrode tip diameters with half the particle size. Extension of this system down to the level of single molecules is envisaged, which will avoid ensemble averaging at still statistically large sample sizes.
Classification of biological cells using a sound wave based flow cytometer
NASA Astrophysics Data System (ADS)
Strohm, Eric M.; Gnyawali, Vaskar; Van De Vondervoort, Mia; Daghighi, Yasaman; Tsai, Scott S. H.; Kolios, Michael C.
2016-03-01
A flow cytometer that uses sound waves to determine the size of biological cells is presented. In this system, a microfluidic device made of polydimethylsiloxane (PDMS) was developed to hydrodynamically flow focus cells in a single file through a target area. Integrated into the microfluidic device was an ultrasound transducer with a 375 MHz center frequency, aligned opposite the transducer was a pulsed 532 nm laser focused into the device by a 10x objective. Each passing cell was insonfied with a high frequency ultrasound pulse, and irradiated with the laser. The resulting ultrasound and photoacoustic waves from each cell were analyzed using signal processing methods, where features in the power spectra were compared to theoretical models to calculate the cell size. Two cell lines with different size distributions were used to test the system: acute myeloid leukemia cells (AML) and melanoma cells. Over 200 cells were measured using this system. The average calculated diameter of the AML cells was 10.4 +/- 2.5 μm using ultrasound, and 11.4 +/- 2.3 μm using photoacoustics. The average diameter of the melanoma cells was 16.2 +/- 2.9 μm using ultrasound, and 18.9 +/- 3.5 μm using photoacoustics. The cell sizes calculated using ultrasound and photoacoustic methods agreed with measurements using a Coulter Counter, where the AML cells were 9.8 +/- 1.8 μm and the melanoma cells were 16.0 +/- 2.5 μm. These results demonstrate a high speed method of assessing cell size using sound waves, which is an alternative method to traditional flow cytometry techniques.
Liu, Huolong; Galbraith, S C; Ricart, Brendon; Stanton, Courtney; Smith-Goettler, Brandye; Verdi, Luke; O'Connor, Thomas; Lee, Sau; Yoon, Seongkyu
2017-06-15
In this study, the influence of key process variables (screw speed, throughput and liquid to solid (L/S) ratio) of a continuous twin screw wet granulation (TSWG) was investigated using a central composite face-centered (CCF) experimental design method. Regression models were developed to predict the process responses (motor torque, granule residence time), granule properties (size distribution, volume average diameter, yield, relative width, flowability) and tablet properties (tensile strength). The effects of the three key process variables were analyzed via contour and interaction plots. The experimental results have demonstrated that all the process responses, granule properties and tablet properties are influenced by changing the screw speed, throughput and L/S ratio. The TSWG process was optimized to produce granules with specific volume average diameter of 150μm and the yield of 95% based on the developed regression models. A design space (DS) was built based on volume average granule diameter between 90 and 200μm and the granule yield larger than 75% with a failure probability analysis using Monte Carlo simulations. Validation experiments successfully validated the robustness and accuracy of the DS generated using the CCF experimental design in optimizing a continuous TSWG process. Copyright © 2017 Elsevier B.V. All rights reserved.
Influence of race and crossbreeding on casein micelles size.
Freitas, Denise R; Fonseca, Leorges M; Souza, Fernando N; Ladeira, Cristiane V G; Diniz, Soraia A; Haddad, João Paulo A; Ferreira, Diêgo S; Santoro, Marcelo M; Cerqueira, Mônica M O P
2015-05-01
Casein (CN) micelles are colloidal aggregates of protein dispersed in milk, the importance of which in the dairy industry is related to functionality and yield in dairy products. The objective of this work was to investigate the correlation of milk CN micelles diameter from Holstein and Zebu crossbreds with milk composition (protein, fat, lactose, total and nonfat solids and milk urea nitrogen), somatic cell count (SCC), age, lactation stage and production. Average casein micelles diameters of milk samples obtained from 200 cows were measured using photon correlation spectroscopy and multiple regression analysis was used to find relationship between variables. CN micelle diameter, SCC and nonfat solids were different between animals with different Holstein crossbreed ratios, which suggests influence of genetic factors, mammary gland health and milk composition. Overall, results indicate the potential use of CN micelle diameter as a tool to select animals to produce milk more suitable to cheese production. © 2014 Japanese Society of Animal Science.
NASA Technical Reports Server (NTRS)
Remer, Lorraine A.; Bruintjes, Roelof; Holben, Brent N.; Christopher, Sundar
1999-01-01
We take advantage of the May 1998 biomass burning event in Southern Mexico to test the global applicability of a smoke aerosol size model developed from data observed in South America. The Mexican event is an unique opportunity to observe well-aged, residual smoke. Observations of smoke aerosol size distribution made from vertical profiles of airborne in situ measurements show an inverse relationship between concentration and particle size that suggests the aging process continues more than a week after the smoke is separated from its fire sources. The ground-based radiometer retrievals show that the column-averaged, aged, Mexican smoke particles are larger (diameter = 0.28 - 0.33 micrometers) than the mean smoke particles in South America (diameter = 0.22 - 0.30 micrometers). However, the difference (delta - 0.06 micrometer) translates into differences in backscattering coefficient of only 4-7% and an increase of direct radiative forcing of only 10%.
Determination of the manning coefficient from measured bed roughness in natural channels
Limerinos, John Thomas
1970-01-01
This report presents the results of a study to test the hypothesis that basic values of the Manning roughness coefficient of stream channels may be related to (1) some characteristic size of the streambed particles and to (2) the distribution of particle size. These two elements involving particle size can be combined into a single element by weighting characteristic particle sizes. The investigation was confined to channels with coarse bed material to avoid the complication of bed-form roughness that is associated with alluvial channels composed of fine bed material. Fifty current-meter measurements of discharge and appropriate field surveys were made at 11 sites on California streams for the purpose of computing the roughness coefficient, n, by the Manning formula. The test sites were selected to give a wide range in average size of bed material, and the discharge measurements and surveys were made at such times as to provide data covering a suitable range in stream depth. The sites selected were relatively free of the extraneous flow-retarding effects associated with irregular channel conformation and streambank vegetation. The characteristic bed-particle sizes used in the analyses were the 16,- 50,- and 84-percentile sizes as obtained from a cumulative frequency distribution of the diameters of randomly sampled surficial bed material. Separate distributions were computed for the minimum and intermediate values of the three diameters of a particle. The minimum diameters of the streambed particles were used in the study because a particle at rest on the bed invariably has its minimum diameter in the vertical position; this diameter is, therefore, the most representative measure of roughness height. The intermediate diameter was also studied because this is the diameter most easily measurable-either by sieve analysis or by photographic techniques--and--because it is the diameter that had been used in previous studies by other investigators. No significant difference in reliability was found between the results obtained using minimum diameters and those obtained using intermediate diameters. In analyzing the field data, the roughness parameter, n/R1/6 (where R is hydraulic radius), was related to relative smoothness, R/d (where d is a characteristic, or weighted characteristic, particle size). The parameter n/R1/6, rather than n, was used because it is directly proportional to the square root of the Darcy-Weisbach friction factor, f, which is more widely used in theoretical studies of hydraulic friction. If the transformation of n/R1/6 to vf is made, the relations obtained in this study are of a form that is identical with that of the theoretical friction equation obtained by several investigators and that derived from field data by Leopold and Wolman (1957). The constants in the equation vary, of course, with the characteristic particle size used. The relations best fitting the field data for this study were obtained by using either a characteristic particle diameter equal to the 84-percentile size (d84, the size equal to, or exceeding, that of 84 percent of the streambed particles), or a diameter obtained by weighting three characteristic particle sizes (dw, the size obtained by assigning a weight of 0.1 to d16 , a weight of 0.3 to d50 , and a weight of 0.6 to d84). The use of d84 alone gave slightly better results than the use of dw, and, in addition, the use of d84 alone is attractive from a standpoint of simplicity. It is difficult, however, to rationalize the use of d84 alone because of the implication that the distribution of sizes is irrelevant, and it matters not at all whether 84 percent of the bed material is sand or whether it is large cobbles, as long as 16 percent of the material is of greater size. Consequently, the author recommends the use of dw rather than d84 , although there was no unanimity of opinion on this recommendation among his colleagues who reviewed this paper. The reader is free to
Aerodynamic Resistance of a Ball-Tube Mill During Transport of a Polydisperse Coal Gas Suspension
NASA Astrophysics Data System (ADS)
Ivanov, S. D.; Kudryashov, A. N.; Oshchepkov, V. V.
2018-03-01
Analysis of experimental data on aerodynamic resistance of a ball-tube mill is given. It is shown that this resistance has two components brought about by the pressure losses resulting from the injection of dust particles into the main flow after coal grinding and from the transport of homogeneous gas suspension flow. A dimensionless equation has been obtained for the dependence of the pressure loss in flow of a homogeneous dust-air mixture on Reynolds number. Functional dependences of the mean-square velocity of the floating of coal particles and of their average diameter on the polydispersity parameters of coal dust have been found. An empirical dependence of pressure loss due to the injection of a polydisperse coal gas suspension into the main flow on the average velocity of floating of coal particles, their average size, and on the size of the mill has been obtained.
Aperture averaging and BER for Gaussian beam in underwater oceanic turbulence
NASA Astrophysics Data System (ADS)
Gökçe, Muhsin Caner; Baykal, Yahya
2018-03-01
In an underwater wireless optical communication (UWOC) link, power fluctuations over finite-sized collecting lens are investigated for a horizontally propagating Gaussian beam wave. The power scintillation index, also known as the irradiance flux variance, for the received irradiance is evaluated in weak oceanic turbulence by using the Rytov method. This lets us further quantify the associated performance indicators, namely, the aperture averaging factor and the average bit-error rate (
Aerodynamic Resistance of a Ball-Tube Mill During Transport of a Polydisperse Coal Gas Suspension
NASA Astrophysics Data System (ADS)
Ivanov, S. D.; Kudryashov, A. N.; Oshchepkov, V. V.
2018-05-01
Analysis of experimental data on aerodynamic resistance of a ball-tube mill is given. It is shown that this resistance has two components brought about by the pressure losses resulting from the injection of dust particles into the main flow after coal grinding and from the transport of homogeneous gas suspension flow. A dimensionless equation has been obtained for the dependence of the pressure loss in flow of a homogeneous dust-air mixture on Reynolds number. Functional dependences of the mean-square velocity of the floating of coal particles and of their average diameter on the polydispersity parameters of coal dust have been found. An empirical dependence of pressure loss due to the injection of a polydisperse coal gas suspension into the main flow on the average velocity of floating of coal particles, their average size, and on the size of the mill has been obtained.
NASA Technical Reports Server (NTRS)
Elsaesser, Greg; Del Genio, Anthony
2015-01-01
The CMIP5 configurations of the GISS Model-E2 GCM simulated a mid- and high latitude ice IWP that decreased by 50 relative to that simulated for CMIP3 (Jiang et al. 2012; JGR). Tropical IWP increased by 15 in CMIP5. While the tropical IWP was still within the published upper-bounds of IWP uncertainty derived using NASA A-Train satellite observations, it was found that the upper troposphere (200 mb) ice water content (IWC) exceeded the published upper-bound by a factor of 2. This was largely driven by IWC in deep-convecting regions of the tropics.Recent advances in the model-E2 convective parameterization have been found to have a substantial impact on tropical IWC. These advances include the development of both a cold pool parameterization (Del Genio et al. 2015) and new convective ice parameterization. In this presentation, we focus on the new parameterization of convective cloud ice that was developed using data from the NASA TC4 Mission. Ice particle terminal velocity formulations now include information from a number of NASA field campaigns. The new parameterization predicts both an ice water mass weighted-average particle diameter and a particle cross sectional area weighted-average size diameter as a function of temperature and ice water content. By assuming a gamma-distribution functional form for the particle size distribution, these two diameter estimates are all that are needed to explicitly predict the distribution of ice particles as a function of particle diameter.GCM simulations with the improved convective parameterization yield a 50 decrease in upper tropospheric IWC, bringing the tropical and global mean IWP climatologies into even closer agreement with the A-Train satellite observation best estimates.
NASA Astrophysics Data System (ADS)
Elsaesser, G.; Del Genio, A. D.
2015-12-01
The CMIP5 configurations of the GISS Model-E2 GCM simulated a mid- and high-latitude ice IWP that decreased by ~50% relative to that simulated for CMIP3 (Jiang et al. 2012; JGR). Tropical IWP increased by ~15% in CMIP5. While the tropical IWP was still within the published upper-bounds of IWP uncertainty derived using NASA A-Train satellite observations, it was found that the upper troposphere (~200 mb) ice water content (IWC) exceeded the published upper-bound by a factor of ~2. This was largely driven by IWC in deep-convecting regions of the tropics. Recent advances in the model-E2 convective parameterization have been found to have a substantial impact on tropical IWC. These advances include the development of both a cold pool parameterization (Del Genio et al. 2015) and new convective ice parameterization. In this presentation, we focus on the new parameterization of convective cloud ice that was developed using data from the NASA TC4 Mission. Ice particle terminal velocity formulations now include information from a number of NASA field campaigns. The new parameterization predicts both an ice water mass weighted-average particle diameter and a particle cross sectional area weighted-average size diameter as a function of temperature and ice water content. By assuming a gamma-distribution functional form for the particle size distribution, these two diameter estimates are all that are needed to explicitly predict the distribution of ice particles as a function of particle diameter. GCM simulations with the improved convective parameterization yield a ~50% decrease in upper tropospheric IWC, bringing the tropical and global mean IWP climatologies into even closer agreement with the A-Train satellite observation best estimates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McMillan, K; Bostani, M; McNitt-Gray, M
2014-06-15
Purpose: To demonstrate the feasibility of using existing data stored within the DICOM header of certain CT localizer radiographs as a patient size metric for calculating CT size-specific dose estimates (SSDE). Methods: For most Siemens CT scanners, the CT localizer radiograph (topogram) contains a private DICOM field that stores an array of numbers describing AP and LAT attenuation-based measures of patient dimension. The square root of the product of the AP and LAT size data, which provides an estimate of water-equivalent-diameter (WED), was calculated retrospectively from topogram data of 20 patients who received clinically-indicated abdomen/pelvis (n=10) and chest (n=10) scansmore » (WED-topo). In addition, slice-by-slice water-equivalent-diameter (WED-image) and effective diameter (ED-image) values were calculated from the respective image data. Using TG-204 lookup tables, size-dependent conversion factors were determined based upon WED-topo, WED-image and ED-image values. These conversion factors were used with the reported CTDIvol to calculate slice-by-slice SSDE for each method. Averaging over all slices, a single SSDE value was determined for each patient and size metric. Patientspecific SSDE and CTDIvol values were then compared with patientspecific organ doses derived from detailed Monte Carlo simulations of fixed tube current scans. Results: For abdomen/pelvis scans, the average difference between liver dose and CTDIvol, SSDE(WED-topo), SSDE(WED-image), and SSDE(ED-image) was 18.70%, 8.17%, 6.84%, and 7.58%, respectively. For chest scans, the average difference between lung dose and CTDIvol, SSDE(WED-topo), SSDE(WED-image), and SSDE(ED-image) was 25.80%, 3.33%, 4.11%, and 7.66%, respectively. Conclusion: SSDE calculated using WED derived from data in the DICOM header of the topogram was comparable to SSDE calculated using WED and ED derived from axial images; each of these estimated organ dose to within 10% for both abdomen/pelvis and chest CT examinations. The topogrambased method has the advantage that WED data are already provided and therefore available without additional post-processing of the image data. Funding Support: NIH Grant R01-EB017095; Disclosures - Michael McNitt-Gray: Institutional Research Agreement, Siemens AG; Research Support, Siemens AG; Consultant, Flaherty Sensabaugh Bonasso PLLC; Consultant, Fulbright and Jaworski; Disclosures - Cynthia McCollough: Research Grant, Siemens Healthcare.« less
Benavente-Fernández, Isabel; Rodríguez-Zafra, Enrique; León-Martínez, Jesús; Jiménez-Gómez, Gema; Ruiz-González, Estefanía; Fernández-Colina, Rosalía Campuzano; Lechuga-Sancho, Alfonso M; Lubián-López, Simón P
2018-04-03
Purpose To establish cross-sectional and longitudinal reference values for cerebellar size in preterm infants with normal neuroimaging findings and normal 2-year neurodevelopmental outcome by using cranial ultrasonography (US). Materials and Methods This prospective study consecutively enrolled preterm infants admitted to a neonatal intensive care unit from June 2011 to June 2014 with a birth weight of less than or equal to 1500 g and/or gestational age (GA) of less than or equal to 32 weeks. They underwent weekly cranial US from birth to term-equivalent age and magnetic resonance (MR) imaging at term-equivalent age. The infants underwent neurodevelopmental assessments at age 2 years with Bayley Scales of Infant and Toddler Development, 3rd edition (BSID-III). Patients with adverse outcomes (death or abnormal neuroimaging findings and/or BSID-III score of <85) were excluded. The following measurements were performed: vermis height, craniocaudal diameter, superior width, inferior width, vermis area, and transcerebellar diameter. Statistical analyses were conducted by using multilevel analyses. Results A total of 137 infants with a mean GA at birth of 29.4 weeks (range, 25-32 weeks) were included. Transcerebellar diameter increased by 1.04 mm per week on average; vermis height and craniocaudal diameter increased by 0.55 mm and 0.59 mm, respectively. Superior vermian width increased by an average of 0.45 mm, whereas inferior vermian width increased by an average of 0.51 mm per week. Vermis area was found to increase by 0.22 cm 2 per week on average. The sex effect was significant (female lower than male) for vermis height (P < .05), craniocaudal diameter (P < .05), inferior vermian width (P <. 05), and vermis area (P <. 05). Conclusion Cross-sectional and longitudinal reference values were established for cerebellar growth in preterm infants, which may be included in routine cranial US. © RSNA, 2018 Online supplemental material is available for this article.
Causes of intraspecific variation in body size among trematode metacercariae.
Saldanha, I; Leung, T L F; Poulin, R
2009-09-01
Inequalities in body size among adult helminths can result in inequalities in reproductive output, with consequences for population dynamics and genetics. These inequalities can result from growth differences among larval worms inside intermediate hosts that persist into the adult stage. Here, we investigate the effects of both host body size and intensity of infection on the sizes of metacercariae of the trematode Maritrema novaezealandensis (Microphallidae) inside their second intermediate host, the isopod Paridotea ungulata (Idoteidae). Among the more than 1500 metacercariae recovered and individually measured, there was no relationship between the mean diameter of metacercarial cysts per isopod and isopod body length. However, intensity of infection correlated negatively with the mean diameter of cysts within an isopod, i.e. metacercariae in crowded infections attained smaller sizes on average. In contrast, the variability in cyst sizes per isopod, measured as the coefficient of variation, was independent of both isopod body length and infection intensity. Our results show that a disproportionate number of relatively small metacercariae come from the relatively few hosts in which a large fraction of all metacercariae are aggregated. The combination of aggregation and intensity-dependent growth generates inequalities in sizes among metacercariae that will be passed on to adult worm populations in definitive hosts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rao, Suraj; Cunningham, Ross; Ozturk, Tugce
Aluminum alloys are candidate materials for weight critical applications because of their excellent strength and stiffness to weight ratio. However, defects such as voids decrease the strength and fatigue life of these alloys, which can limit the application of Selective Laser Melting. In this study, the average volume fraction, average size, and size distribution of pores in Al10-Si-1Mg samples built using Selective Laser Melting have been characterized. Synchrotron high energy X-rays were used to perform computed tomography on volumes of order one cubic millimeter with a resolution of approximately 1.5 μm. Substantial variations in the pore size distributions were foundmore » as a function of process conditions. Even under conditions that ensured that all locations were melted at least once, a significant number density was found of pores above 5 μm in diameter.« less
Distribution-of-cut guides for thinning in Allegheny hardwoods: a review
Christopher A. Nowak; David A. Marquis
1997-01-01
Distribution-of-cut guidelines describe the amount of stand density to be removed from broad size classes of trees to attain a target residual stand density and stand structure. Current guides for thinning Allegheny hardwoods recommend that 75 percent of the cut relative stand density be taken from below the average stand diameter and 25 percent from above. These...
Thirty-five-year growth of ponderosa pine saplings in response to thinning and understory removal.
P.H. Cochran; James W. Barrett
1999-01-01
Diameter increments for individual trees increased curvilinearly and stand basal area increments decreased curvilinearly as spacing increased from 6.6 to 26.4 feet. Average height growth of all trees increased linearly, and stand cubic volume growth decreased linearly as spacing increased. Large differences in tree sizes developed over the 35 years of study with...
A new type of density-management diagram for slash pine plantations
Curtis L. VanderSchaaf
2006-01-01
Many Density-Management Diagrams (DMD) have been developed for conifer species throughout the world based on stand density index (SDI). The diagrams often plot the logarithm of average tree size (volume, weight, or quadratic mean diameter) over the logarithm of trees per unit area. A new type of DMD is presented for slash pine (Pinus elliottii var elliottii)...
NASA Astrophysics Data System (ADS)
Çakal, G. Ö.; Eroğlu, İ.; Özkar, S.
2006-04-01
Colemanite, one of the important boron minerals, is dissolved in aqueous sulfuric acid to produce boric acid. In this reaction, gypsum is obtained as a by-product. Gypsum crystals are in the shape of thin needles. These crystals should be grown to an easily filterable size in order to increase the production yield and purity of boric acid. In this paper, the particle size distributions and the volume-weighted mean diameters of the gypsum crystals obtained in batch and continuous flow systems were compared. Experiments in both batch and continuous reactors were performed at a temperature of 85 °C, a stirring rate of 400 rpm, and the inlet CaO to SO42- molar ratio of 1.0 using colemanite mineral in particle size smaller than 150 μm. The average diameter of the gypsum crystals obtained at 3.5 h from the batch reactor was found to be 37-41 μm. This value for the continuous system at steady state was observed to change between 44-163 μm. The particle size of the gypsum crystals was found to increase with the residence time of the solid in the continuous system.
Controllable Fabrication of Non-Close-Packed Colloidal Nanoparticle Arrays by Ion Beam Etching
NASA Astrophysics Data System (ADS)
Yang, Jie; Zhang, Mingling; Lan, Xu; Weng, Xiaokang; Shu, Qijiang; Wang, Rongfei; Qiu, Feng; Wang, Chong; Yang, Yu
2018-06-01
Polystyrene (PS) nanoparticle films with non-close-packed arrays were prepared by using ion beam etching technology. The effects of etching time, beam current, and voltage on the size reduction of PS particles were well investigated. A slow etching rate, about 9.2 nm/min, is obtained for the nanospheres with the diameter of 100 nm. The rate does not maintain constant with increasing the etching time. This may result from the thermal energy accumulated gradually in a long-time bombardment of ion beam. The etching rate increases nonlinearly with the increase of beam current, while it increases firstly then reach its saturation with the increase of beam voltage. The diameter of PS nanoparticles can be controlled in the range from 34 to 88 nm. Based on the non-close-packed arrays of PS nanoparticles, the ordered silicon (Si) nanopillars with their average diameter of 54 nm are fabricated by employing metal-assisted chemical etching technique. Our results pave an effective way to fabricate the ordered nanostructures with the size less than 100 nm.
NASA Technical Reports Server (NTRS)
Cutten, D. R.; Pueschel, R. F.; Srivastava, V.; Clarke, A. D.; Rothermel, J.; Spinhirne, J. D.; Menzies, R. T.
1996-01-01
Aerosol concentrations and size distributions in the middle and upper troposphere over the remote Pacific Ocean were measured with a forward scattering spectrometer probe (FSSP) on the NASA DC-8 aircraft during NASA's Global Backscatter Experiment (GLOBE) in May-June 1990. The FSSP size channels were recalibrated based on refractive index estimates from flight-level aerosol volatility measurements with a collocated laser optical particle counter (LOPC). The recalibrated FSSP size distributions were averaged over 100-s intervals, fitted with lo-normal distributions and used to calculate aerosol backscatter coefficients at selected wavelengths. The FSSP-derived backscatter estimates were averaged over 300-s intervals to reduce large random fluctuations. The smoothed FSSP aerosol backscatter coefficients were then compared with LOPC-derived backscatter values and with backscatter measured at or near flight level from four lidar systems operating at 0.53, 1.06, 9.11, 9.25, and 10.59 micrometers. Agreement between FSSP-derived and lidar-measured backscatter was generally best at flight level in homogeneous aerosol fields and at high backscatter values. FSSP data often underestimated low backscatter values especially at the longer wavelengths due to poor counting statistics for larger particles (greater than 0.8 micrometers diameter) that usually dominate aerosol backscatter at these wavelengths. FSSP data also underestimated backscatter at shorter wavelengths when particles smaller than the FSSP lower cutoff diameter (0.35 micrometers) made significant contributions to the total backscatter.
NASA Astrophysics Data System (ADS)
Kubo-Irie, Miyoko; Uchida, Hiroki; Mastuzawa, Shotaro; Yoshida, Yasuko; Shinkai, Yusuke; Suzuki, Kenichiro; Yokota, Satoshi; Oshio, Shigeru; Takeda, Ken
2014-02-01
Titanium dioxide nanoparticles (nano-TiO2), believed to be inert and safe, are used in many products especially rutile-type in cosmetics. Detection, localization, and count of nanoparticles in tissue sections are of considerable current interest. Here, we evaluate the dose-dependent biodistribution of rutile-type nano-TiO2 exposure during pregnancy on offspring testes. Pregnant mice were subcutaneously injected five times with 0.1 ml of sequentially diluted of nano-TiO2 powder, 35 nm with primary diameter, suspensions (1, 10, 100, or 1,000 μg/ml), and received total doses of 0.5, 5, 50, and 500 μg, respectively. Prior to injection, the size distribution of nano-TiO2 was analyzed by dynamic light scattering measurement. The average diameter was increased in a dose-dependent manner. The most diluted concentration, 1 μg/ml suspension, contained small agglomerates averaging 193.3 ± 5.4 nm in diameter. The offspring testes were examined at 12 weeks postpartum. Individual particle analysis in testicular sections under scanning and transmission electron microscopy enabled us to understand the biodistribution. The correlation between nano-TiO2 doses injected to pregnant mice, and the number of agglomerates in the offspring testes was demonstrated to be dose-dependent by semiquantitative evaluation. However, the agglomerate size was below 200 nm in the testicular sections of all recipient groups, independent from the injected dose during pregnancy.
Gasser, T C; Nchimi, A; Swedenborg, J; Roy, J; Sakalihasan, N; Böckler, D; Hyhlik-Dürr, A
2014-03-01
To translate the individual abdominal aortic aneurysm (AAA) patient's biomechanical rupture risk profile to risk-equivalent diameters, and to retrospectively test their predictability in ruptured and non-ruptured aneurysms. Biomechanical parameters of ruptured and non-ruptured AAAs were retrospectively evaluated in a multicenter study. General patient data and high resolution computer tomography angiography (CTA) images from 203 non-ruptured and 40 ruptured aneurysmal infrarenal aortas. Three-dimensional AAA geometries were semi-automatically derived from CTA images. Finite element (FE) models were used to predict peak wall stress (PWS) and peak wall rupture index (PWRI) according to the individual anatomy, gender, blood pressure, intra-luminal thrombus (ILT) morphology, and relative aneurysm expansion. Average PWS diameter and PWRI diameter responses were evaluated, which allowed for the PWS equivalent and PWRI equivalent diameters for any individual aneurysm to be defined. PWS increased linearly and PWRI exponentially with respect to maximum AAA diameter. A size-adjusted analysis showed that PWS equivalent and PWRI equivalent diameters were increased by 7.5 mm (p = .013) and 14.0 mm (p < .001) in ruptured cases when compared to non-ruptured controls, respectively. In non-ruptured cases the PWRI equivalent diameters were increased by 13.2 mm (p < .001) in females when compared with males. Biomechanical parameters like PWS and PWRI allow for a highly individualized analysis by integrating factors that influence the risk of AAA rupture like geometry (degree of asymmetry, ILT morphology, etc.) and patient characteristics (gender, family history, blood pressure, etc.). PWRI and the reported annual risk of rupture increase similarly with the diameter. PWRI equivalent diameter expresses the PWRI through the diameter of the average AAA that has the same PWRI, i.e. is at the same biomechanical risk of rupture. Consequently, PWRI equivalent diameter facilitates a straightforward interpretation of biomechanical analysis and connects to diameter-based guidelines for AAA repair indication. PWRI equivalent diameter reflects an additional diagnostic parameter that may provide more accurate clinical data for AAA repair indication. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Relationship between the Foveal Avascular Zone and Foveal Pit Morphology
Dubis, Adam M.; Hansen, Benjamin R.; Cooper, Robert F.; Beringer, Joseph; Dubra, Alfredo; Carroll, Joseph
2012-01-01
Purpose. To assess the relationship between foveal pit morphology and size of the foveal avascular zone (FAZ). Methods. Forty-two subjects were recruited. Volumetric images of the macula were obtained using spectral domain optical coherence tomography. Images of the FAZ were obtained using either a modified fundus camera or an adaptive optics scanning light ophthalmoscope. Foveal pit metrics (depth, diameter, slope, volume, and area) were automatically extracted from retinal thickness data, whereas the FAZ was manually segmented by two observers to extract estimates of FAZ diameter and area. Results. Consistent with previous reports, the authors observed significant variation in foveal pit morphology. The average foveal pit volume was 0.081 mm3 (range, 0.022 to 0.190 mm3). The size of the FAZ was also highly variable between persons, with FAZ area ranging from 0.05 to 1.05 mm2 and FAZ diameter ranging from 0.20 to 1.08 mm. FAZ area was significantly correlated with foveal pit area, depth, and volume; deeper and broader foveal pits were associated with larger FAZs. Conclusions. Although these results are consistent with predictions from existing models of foveal development, more work is needed to confirm the developmental link between the size of the FAZ and the degree of foveal pit excavation. In addition, more work is needed to understand the relationship between these and other anatomic features of the human foveal region, including peak cone density, rod-free zone diameter, and Henle fiber layer. PMID:22323466
Production of monodisperse, polymeric microspheres
NASA Technical Reports Server (NTRS)
Rembaum, Alan (Inventor); Rhim, Won-Kyu (Inventor); Hyson, Michael T. (Inventor); Chang, Manchium (Inventor)
1990-01-01
Very small, individual polymeric microspheres with very precise size and a wide variation in monomer type and properties are produced by deploying a precisely formed liquid monomer droplet, suitably an acrylic compound such as hydroxyethyl methacrylate into a containerless environment. The droplet which assumes a spheroid shape is subjected to polymerizing radiation such as ultraviolet or gamma radiation as it travels through the environment. Polymeric microspheres having precise diameters varying no more than plus or minus 5 percent from an average size are recovered. Many types of fillers including magnetic fillers may be dispersed in the liquid droplet.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, H; Gopalakrishnan, M; Lee, P
2014-06-01
Purpose: To evaluate the dosimetric impact of cylinder size in high dose rate Brachytherapy for primary vaginal cancers. Methods: Patients treated with HDR vaginal vault radiation in a list of cylinders ranging from 2.5 to 4 cm in diameter at 0.5 cm increment were analyzed. All patients’ doses were prescribed at the 0.5 cm from the vaginal surface with different treatment lengths. A series of reference points were created to optimize the dose distribution. The fraction dose was 5.5 Gy, the treatment was repeated for 4 times in two weeks. A cylinder volume was contoured in each case according tomore » the prescribed treatment length, and then expanded to 5 mm to get a volume Cylinder-5mm-exp. A volume of PTV-Eval was obtained by subtracting the cylinder volume from the Cylinder-5mm-exp. The shell volume, PTV-Eval serves as the target volume for dosimetric evaluation. Results: DVH curves and average doses of PTV-Eval were obtained. Our results indicated that the DVH curves shifted toward higher dose side when larger cylinder was used instead of smaller ones. When 3.0 cm cylinder was used instead of 2.5 cm, for 3.0 cm treatment length, the average dose only increased 1%, from 790 to 799 cGy. However, the average doses for 3.5 and 4 cm cylinders respectively are 932 and 1137 cGy at the same treatment length. For 5.0 cm treatment length, the average dose is 741 cGy for 2.5 cm cylinder, and 859 cGy for 3 cm cylinder. Conclusion: Our data analysis suggests that for the vaginal intracavitary HDRBT, the average dose is at least 35% larger than the prescribed dose in the studied cases; the size of the cylinder will impact the dose delivered to the target volume. The cylinder with bigger diameter tends to deliver larger average dose to the PTV-Eval.« less
NASA Astrophysics Data System (ADS)
Wang, Yu-Nan; Yang, Jian; Xin, Xiu-Ling; Wang, Rui-Zhi; Xu, Long-Yun
2016-04-01
In the present study, the effect of cooling conditions on the evolution of non-metallic inclusions in high manganese TWIP steels was investigated based on experiments and thermodynamic calculations. In addition, the formation and growth behavior of AlN inclusions during solidification under different cooling conditions were analyzed with the help of thermodynamics and dynamics. The inclusions formed in the high manganese TWIP steels are classified into nine types: (1) AlN; (2) MgO; (3) CaS; (4) MgAl2O4; (5) AlN + MgO; (6) MgO + MgS; (7) MgO + MgS + CaS; (8) MgO + CaS; (9) MgAl2O4 + MgS. With the increase in the cooling rate, the volume fraction and area ratio of inclusions are almost constant; the size of inclusions decreases and the number density of inclusions increases in the steels. The thermodynamic results of inclusion types calculated with FactSage are consistent with the observed results. With increasing cooling rate, the diameter of AlN decreases. When the cooling rate increases from 0.75 to 4.83 K s-1, the measured average diameter of AlN decreases from 4.49 to 2.42 μm. Under the high cooling rate of 4.83 K s-1, the calculated diameter of AlN reaches 3.59 μm at the end of solidification. However, the calculated diameter of AlN increases to approximately 5.93 μm at the end of solidification under the low cooling rate of 0.75 K s-1. The calculated diameter of AlN decreases with increasing cooling rate. The theoretical calculation results of the change in diameter of AlN under the different cooling rates have the same trend with the observed results. The existences of inclusions in the steels, especially AlN which average sizes are 2.42 and 4.49 μm, respectively, are not considered to have obvious influences on the hot ductility.
NASA Astrophysics Data System (ADS)
Kamaruzaman, Nurul Asyikin; Yusoff, Abdull Rahim Mohd; Buang, Nor Aziah; Salleh, Nik Ghazali Nik
2017-12-01
Electrospinning is one of the techniques used in the fabrication of nanofibers. Polycaprolactone (PCL), is a biodegradable polymer which was commonly electrospun without the presence of nanoparticles as additives and/or filler in the applications such as tissue engineering, biosensors, filtration, wound dressings, drug delivery and enzyme immobilization. In this study, via FESEM analyses, the effects on the diameter and morphology of PCL nanofibers was investigated with respect to various concentration of selenium nanoparticles (SeNP). Increasing the concentration of SeNP from 0.2 to 1.0% (w/v) resulted in increased of fiber diameter as well as the density of the nanofiber networking. Consequently, the formation of beads have also increased with the increment of the concentration of SeNP. The images from FESEM micrographs showed the formation of "aligned fibers" with the average size of less than 550 nm. The optimized concentration of SeNP obtained was 0.4 % w/v for the formation of aligned fibers with a uniform diameter in size and the least formation of beads in the matrices. Aligned nanofibers are biocompatible and can be used in tissue engineering and wound dressing applications. Meanwhile, nanofibers with beads are suitable for filtration design in water and gaseous applications.
Influence of film dimensions on film droplet formation.
Holmgren, Helene; Ljungström, Evert
2012-02-01
Aerosol particles may be generated from rupturing liquid films through a droplet formation mechanism. The present work was undertaken with the aim to throw some light on the influence of film dimensions on droplet formation with possible consequences for exhaled breath aerosol formation. The film droplet formation process was mimicked by using a purpose-built device, where fluid films were spanned across holes of known diameters. As the films burst, droplets were formed and the number and size distributions of the resulting droplets were determined. No general relation could be found between hole diameter and the number of droplets generated per unit surface area of fluid film. Averaged over all film sizes, a higher surface tension yielded higher concentrations of droplets. Surface tension did not influence the resulting droplet diameter, but it was found that smaller films generated smaller droplets. This study shows that small fluid films generate droplets as efficiently as large films, and that droplets may well be generated from films with diameters below 1 mm. This has implications for the formation of film droplets from reopening of closed airways because human terminal bronchioles are of similar dimensions. Thus, the results provide support for the earlier proposed mechanism where reopening of closed airways is one origin of exhaled particles.
Sabiri, N E; Castaing, J B; Massé, A; Jaouen, P
2012-01-01
In this study, a sand filter was used to remove micro-algae from seawater feeding aquaculture ponds. A lab-scale sand filter was used to filter 30,000 cells/mL of Heterocapsa triquetra suspension, a non-toxic micro-alga that has morphological and dimensional (15-20 microm) similarities with Alexandrium sp., one of the smallest toxic micro-algae in seawater. Removal efficiency and capture mechanisms for a fixed superficial velocity (3.5 m/h) were evaluated in relation to size distribution and mean diameter of the sand. Various sands (average diameter ranging between 200 microm and 600 microm) were characterized and used as porous media. The structural parameters of the fixed beds were evaluated for each medium using experimental measurements of pressure drop as a function of superficial velocity over a range of Reynolds numbers covering Darcy's regime and the inertial regime. For a filtration cycle of six hours, the best efficiency (E = 90%) was obtained with the following sand characteristics: sieved sand with a range of grain diameter of 100 and 300 microm and a mean grain diameter equal to 256 microm. Results obtained show the influence of the size distribution of sand on the quality of retention of the micro-algae studied.
Calibration and field application of a Sierra Model 235 cascade impactor.
Knuth, R H
1984-06-01
A Sierra Model 235 slotted impactor was used to measure the particle size distribution of ore dust in uranium concentrating mills. The impactor was calibrated at a flow rate of 0.21 m3/min, using solid monodisperse particles of methylene blue and an impaction surface of Whatman #41 filter paper soaked in mineral oil. The reduction from the impactor's design flow rate of 1.13 m3/min (40 cfm) to 0.21 m3/min (7.5 cfm), a necessary adjustment because of the anticipated large particles sizes of ore dust, increased the stage cut-off diameters by an average factor of 2.3. Evaluation of field test results revealed that the underestimation of mass median diameters, often caused by the rebound and reentrainment of solid particles from dry impaction surfaces, was virtually eliminated by using the oiled Whatman #41 impaction surface.
Efficiencies for the statistics of size discrimination.
Solomon, Joshua A; Morgan, Michael; Chubb, Charles
2011-10-19
Different laboratories have achieved a consensus regarding how well human observers can estimate the average orientation in a set of N objects. Such estimates are not only limited by visual noise, which perturbs the visual signal of each object's orientation, they are also inefficient: Observers effectively use only √N objects in their estimates (e.g., S. C. Dakin, 2001; J. A. Solomon, 2010). More controversial is the efficiency with which observers can estimate the average size in an array of circles (e.g., D. Ariely, 2001, 2008; S. C. Chong, S. J. Joo, T.-A. Emmanouil, & A. Treisman, 2008; K. Myczek & D. J. Simons, 2008). Of course, there are some important differences between orientation and size; nonetheless, it seemed sensible to compare the two types of estimate against the same ideal observer. Indeed, quantitative evaluation of statistical efficiency requires this sort of comparison (R. A. Fisher, 1925). Our first step was to measure the noise that limits size estimates when only two circles are compared. Our results (Weber fractions between 0.07 and 0.14 were necessary for 84% correct 2AFC performance) are consistent with the visual system adding the same amount of Gaussian noise to all logarithmically transduced circle diameters. We exaggerated this visual noise by randomly varying the diameters in (uncrowded) arrays of 1, 2, 4, and 8 circles and measured its effect on discrimination between mean sizes. Efficiencies inferred from all four observers significantly exceed 25% and, in two cases, approach 100%. More consistent are our measurements of just-noticeable differences in size variance. These latter results suggest between 62 and 75% efficiency for variance discriminations. Although our observers were no more efficient comparing size variances than they were at comparing mean sizes, they were significantly more precise. In other words, our results contain evidence for a non-negligible source of late noise that limits mean discriminations but not variance discriminations.
Strydom, Matthys; Veldtman, Ruan; Ngwenya, Mzabalazo Z; Esler, Karen J
2017-01-01
Australian Acacia are invasive in many parts of the world. Despite significant mechanical and biological efforts to control their invasion and spread, soil-stored seed banks prevent their effective and sustained removal. In response South Africa has had a strong focus on employing seed reducing biological control agents to deal with Australian Acacia invasion, a programme that is considered as being successful. To provide a predictive understanding for their management, seed banks of four invasive Australian acacia species (Acacia longifolia, A. mearnsii, A. pycnantha and A. saligna) were studied in the Western Cape of South Africa. Across six to seven sites for each species, seed bank sizes were estimated from dense, monospecific stands by collecting 30 litter and soil samples. Average estimated seed bank size was large (1017 to 17261 seed m-2) as was annual input into the seed bank, suggesting that these seed banks are not residual but are replenished in size annually. A clear relationship between seed bank size and stem diameter was established indicating that mechanical clearing should be conducted shortly after fire-stimulated recruitment events or within old populations when seed banks are small. In dense, monospecific stands seed-feeding biological control agents are not effective in reducing seed bank size.
The role of membrane fluidization in the gel-assisted formation of giant polymersomes
Greene, Adrienne C.; Henderson, Ian M.; Gomez, Andrew; ...
2016-07-13
Polymersomes are being widely explored as synthetic analogs of lipid vesicles based on their enhanced stability and potential uses in a wide variety of applications in (e.g., drug delivery, cell analogs, etc.). Controlled formation of giant polymersomes for use in membrane studies and cell mimetic systems, however, is currently limited by low-yield production methodologies. Here, we describe for the first time, how the size distribution of giant poly(ethylene glycol)-poly(butadiene) (PEO-PBD) polymersomes formed by gel-assisted rehydration may be controlled based on membrane fluidization. We first show that the average diameter and size distribution of PEO-PBD polymersomes may be readily increased bymore » increasing the temperature of the rehydration solution. Further, we describe a correlative relationship between polymersome size and membrane fluidization through the addition of sucrose during rehydration, enabling the formation of PEO-PBD polymersomes with a range of diameters, including giant-sized vesicles (>100 μm). This correlative relationship suggests that sucrose may function as a small molecule fluidizer during rehydration, enhancing polymer diffusivity during formation and increasing polymersome size. Altogether the ability to easily regulate the size of PEO-PBD polymersomes based on membrane fluidity, either through temperature or fluidizers, has broadly applicability in areas including targeted therapeutic delivery and synthetic biology.« less
NASA Astrophysics Data System (ADS)
Pais, Antonio; Chessa, Lorenzo A.; Serra, Simone; Ruiu, Alberto; Meloni, Gianni; Donno, Yuri
2007-07-01
The fishery for the edible sea urchin Paracentrotus lividus is of great importance to many European regions, although in some of them this species has shown a wide scale decline in recent years. This paper reports on direct (on P. lividus) and indirect (on the co-occurring but not fished echinoid, Arbacia lixula) effects of sea urchin harvesting in shallow rocky reefs in North-western Sardinia (Italy, central-western Mediterranean Sea), where this activity is intensively practised. Density, size (test diameter), and biomass of both species were assessed in autumn 2004 at two locations impacted by P. lividus fishery, and at two controls within an adjacent Marine Protected Area. Density of P. lividus and A. lixula was significantly greater at the controls than at the exploited locations. The average test diameter of P. lividus was also significantly larger at the controls, where large-sized specimens (i.e. >5 cm) were notably more abundant. The average size of A. lixula did not significantly differ between the impacted locations and the controls. The average biomass of P. lividus was significantly greater at the controls than at the exploited locations, whereas no differences were detected for A. lixula. These results reveal the existence of a heavy fishing impact on P. lividus in North-western Sardinia and the need for regulation of its harvesting to prevent severe direct effects on its populations. Since no indirect effects on A. lixula have been detected, it could be hypothesized that this species did not benefit from P. lividus fishery due to an only moderate competition for habitat and resources between these two echinoids. Implications for management of edible sea urchin fishery are also discussed.
NASA Astrophysics Data System (ADS)
Salam, Abdus; Mamoon, Hassan Al; Ullah, Md. Basir; Ullah, Shah M.
2012-11-01
Aerosol particle size distribution was measured with an aerodynamic particle sizer (APS) spectrometer continuously from January 21 to April 24, 2006 in Dhaka, Bangladesh. Particles number, surface and mass distributions data were stored automatically with Aerosol Instrument Manager (AIM) software on average every half an hour in a computer attached to the APS. The grand total average of number, surface and mass concentrations were 8.2 × 103 ± 7.8 × 103 particles cm-3, 13.3 × 103 ± 11.8 × 103 μm2 cm-3 and 3.04 ± 2.10 mg m-3, respectively. Fine particles with diameter smaller than 1.0 μm aerodynamic diameter (AD) dominated the number concentration, accounted for 91.7% of the total particles indicating vehicular emissions were dominating in Dhaka air either from fossil fuel burning or compressed natural gas (CNGs). The surface and mass concentrations between 0.5 and 1.0 μm AD were about 56.0% and 26.4% of the total particles, respectively. Remarkable seasonal differences were observed between winter and pre-monsoon seasons with the highest monthly average in January and the lowest in April. Aerosol particles in winter were 3.79 times higher for number, 3.15 times for surface and 2.18 times for mass distributions than during the pre-monsoon season. Weekends had lower concentrations than weekdays due to less vehicular traffic in the streets. Aerosol particles concentrations were about 15.0% (ranging from 9.4% to 17.3%) higher during traffic peak hours (6:00am-8:00pm) than off hours (8:00pm-6:00am). These are the first aerosol size distribution measurements with respect to number, surface and mass concentrations in real time at Dhaka, Bangladesh.
French Sizing of Medical Devices is not Fit for Purpose
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kibriya, Nabil, E-mail: nabskib@yahoo.co.uk; Hall, Rebecca; Powell, Steven
PurposeThe purpose of the study is to quantify the variation in the metric equivalent of French size in a range of medical devices, from various manufacturers, used in interventional radiology.MethodsThe labelling of a range of catheters, introducers, drains, balloons, stents, and endografts was examined. Products were chosen to achieve a broad range of French sizes from several manufacturers. To assess manufacturing accuracy, eight devices were selected for measurement using a laser micrometer. The external diameters of three specimens of each device were measured at centimeter intervals along the length of the device to ensure uniformity.ResultsA total of 200 labels ofmore » interventional radiology equipment were scrutinized. The results demonstrate a wide variation in the metric equivalent of French sizing. Labelled products can vary in diameter across the product range by up to 0.79 mm.The devices selected for measurement with the non-contact laser micrometer demonstrate acceptable manufacturing consistency. The external diameter differed by 0.05 mm on average.ConclusionsOur results demonstrate wide variation in the interpretation of the French scale by different manufacturers of medical devices. This has the potential to lead to problems using coaxial systems especially when the products are from different manufacturers. It is recommended that standard labelling should be employed by all manufacturers conveying specific details of the equipment. Given the wide variation in the interpretation of the French scale, our opinion is that this scale either needs to be abandoned or be strictly defined and followed.« less
Effect of Liquid Surface Turbulent Motion on the Vapor Condensation in a Mixing Tank
NASA Technical Reports Server (NTRS)
Lin, C. S.; Hasan, M. M.
1991-01-01
The effect of liquid surface motion on the vapor condensation in a tank mixed by an axial turbulent jet is numerically investigated. The average value (over the interface area) of the root-mean-squared (rms) turbulent velocity at the interface is shown to be linearly increasing with decreasing liquid height and increasing jet diameter for a given tank size. The average rms turbulent velocity is incorporated in Brown et al. (1990) condensation correlation to predict the condensation of vapor on a liquid surface. The results are in good agreement with available condensation data.
Song, Kunlin; Wu, Qinglin; Zhang, Zhen; Ren, Suxia; Lei, Tingzhou; Negulescu, Ioan I; Zhang, Quanguo
2015-07-15
A novel route to fabricate low-cost porous carbon nanofibers (CNFs) using biomass tar, polyacrylonitrile (PAN), and silver nanoparticles has been demonstrated through electrospinning and subsequent stabilization and carbonization processes. The continuous electrospun nanofibers had average diameters ranging from 392 to 903 nm. The addition of biomass tar resulted in increased fiber diameters, reduced thermal stabilities, and slowed cyclization reactions of PAN in the as-spun nanofibers. After stabilization and carbonization, the resultant CNFs showed more uniformly sized and reduced average diameters (226-507 nm) compared to as-spun nanofibers. The CNFs exhibited high specific surface area (>400 m(2)/g) and microporosity, attributed to the combined effects of phase separations of the tar and PAN and thermal decompositions of tar components. These pore characteristics increased the exposures and contacts of silver nanoparticles to the bacteria including Gram-positive Staphylococcus aureus and Gram-negative Escherichia coli, leading to excellent antimicrobial performances of as-spun nanofibers and CNFs. A new strategy is thus provided for utilizing biomass tar as a low-cost precursor to prepare functional CNFs and reduce environmental pollutions associated with direct disposal of tar as an industrial waste.
The morphology of small fresh craters on Mars and the Moon
NASA Astrophysics Data System (ADS)
Daubar, Ingrid J.; Atwood-Stone, C.; Byrne, S.; McEwen, A. S.; Russell, P. S.
2014-12-01
The depth/diameter ratio for new meter- to decameter-scale Martian craters formed in the last ~20 years averages 0.23, only slightly deeper than that expected for simple primary craters on rocky surfaces. Large variations in depth/diameter (d/D) between impact sites indicate that differences between the sites such as target material properties, impact velocity, angle, and physical state of the bolide(s) are important in determining the depth of small craters in the strength regime. On the Moon, the d/D of random fresh small craters with similar diameters averages only 0.10, indicating that either the majority of them are unrecognized secondaries or some proportion are degraded primaries. Older craters such as these may be shallower due to erosional infilling, which is probably not linear over time but more effective over recently disturbed and steeper surfaces, processes that are not yet acting on the new Martian craters. Brand new meter- to decameter-scale craters such as the Martian ones studied here are statistically easily distinguishable as primaries, but the origins of older craters of the same size, such as the lunar ones in this study, are ambiguous.
Suppression of nucleation mode particles by biomass burning in an urban environment: a case study.
Agus, Emily L; Lingard, Justin J N; Tomlin, Alison S
2008-08-01
Measurements of concentrations and size distributions of particles 4.7 to 160 nm were taken using an SMPS during the bonfire and firework celebrations on Bonfire Night in Leeds, UK, 2006. These celebrations provided an opportunity to study size distributions in a unique atmospheric pollution situation during and following a significant emission event due to open biomass burning. A log-normal fitting program was used to determine the characteristics of the modal groups present within hourly averaged size distributions. Results from the modal fitting showed that on bonfire night the smallest nucleation mode, which was present before and after the bonfire event and on comparison weekends, was not detected within the size distribution. In addition, there was a significant shift in the modal diameters of the remaining modes during the peak of the pollution event. Using the concept of a coagulation sink, the atmospheric lifetimes of smaller particles were significantly reduced during the pollution event, and thus were used to explain the disappearance of the smallest nucleation mode as well as changes in particle count mean diameters. The significance for particle mixing state is discussed.
Guo, Fangyuan; Guo, Dingjia; Zhang, Wei; Yan, Qinying; Yang, Yan; Hong, Weiyong; Yang, Gensheng
2017-03-01
Biodegradable polymeric nanoparticles (NPs) have potential therapeutic applications; however, preparing NPs of a specific diameter and uniform size distribution is a challenge. In this work, we fabricated a microchannel system for the preparation of curcumin (Cur)-loaded NPs by the interfacial precipitation method, which rapidly and consistently generated stable NPs with a relatively smaller diameter, narrow size distribution, and higher drug-loading capacity and entrapment efficiency. Poly(ε-caprolactone)-poly(ethylene glycol)-poly (ε-caprolactone) triblock copolymers(PCEC) used as the carrier material was synthesized and characterized. Cur-loaded PCEC NPs had an average size of 167.2nm with a zeta potential of -29.23mV, and showed a loading capacity and drug entrapment efficiency of 15.28%±0.23% and 96.11%±0.13%, respectively. Meanwhile, the NPs demonstrated good biocompatibility and bioavailability, efficient cellular uptake, and long circulation time and a possible liver targeting effect in vivo. These results indicate that the Cur-loaded PCEC NPs can be used as drug carriers in controlled delivery systems and other biomedical applications. Copyright © 2017 Elsevier B.V. All rights reserved.
Effect of Ionic Soil Stabilizers on Soil-Water Characteristic of Special Clay
NASA Astrophysics Data System (ADS)
Cui, D.; Xiang, W.
2011-12-01
The engineering properties of special clay are conventionally improved through the use of chemical additive such as ionic soil stabilizer (ISS). Such special clays are often referred to as stabilized or treated clays. The soil-water characteristic curves (SWCC) of special clays from Henan province and Hubei province were measured both in natural and stabilized conditions using the pressure plate apparatus in the suction range of 0-500 kPa. The SWCC results are used to interpret the special clays behavior due to stabilizer treatment. In addition, relationships were developed between the basic clay and stabilized properties such as specific surface area and pore size distribution. The analysis showed that specific surface area decreases, cumulative pore volume and average pore size diameter decrease, dehydration rate slows and the thickness of water film thins after treatment with Ionic Soil Stabilizer. The research data and interpretation analysis presented here can be extended to understand the water film change behaviors influencing the mechanical and physical properties of stabilized special clay soils. KEY WORDS: ionic soil stabilizer, special clay, pore size diameter, specific surface area, soil water characteristic curve, water film
Pereira, Maira Alves; Mosqueira, Vanessa Carla Furtado; Vilela, José Mário Carneiro; Andrade, Margareth Spangler; Ramaldes, Gilson Andrade; Cardoso, Valbert Nascimento
2008-01-01
The present work describes the preparation, characterization and labelling of conventional and surface-modified nanocapsules (NC) with 99m Tc-HMPAO. The size, size distribution and homogeneity were determined by photon correlation spectroscopy (PCS) and zeta potential by laser doppler anemometry. The morphology and the structural organization were evaluated by atomic force microscopy (AFM). The stability and release profile of the NC were determined in vitro in plasma. The results showed that the use of methylene blue induces significant increase in the encapsulation efficiency of 99m Tc-HMPAO, from 24.4 to 49.8% in PLA NC and 22.37 to 52.93% in the case of PLA-PEG NC (P<0.05) by improving the complex stabilization. The average diameter of NC calculated by PCS varied from 216 to 323 nm, while the average diameter determined by AFM varied from 238 to 426 nm. The AFM analysis of diameter/height ratios suggested a greater homogeneity of the surface-modified PLA-PEG nanocapsules compared to PLA NC concerning their flattening properties. The in vitro release of the 99m Tc-HMPAO in plasma medium was faster for the conventional PLA NC than for the surface-modified NC. For the latter, 60% of the radioactivity remained associated with NC, even after 12h of incubation. The results suggest that the surface-modified 99m Tc-HMPAO-PLA-PEG NC was more stable against label leakage in the presence of proteins and could present better performance as radiotracer in vivo.
A Broadband Microwave Radiometer Technique at X-band for Rain and Drop Size Distribution Estimation
NASA Technical Reports Server (NTRS)
Meneghini, R.
2005-01-01
Radiometric brightess temperatures below about 12 GHz provide accurate estimates of path attenuation through precipitation and cloud water. Multiple brightness temperature measurements at X-band frequencies can be used to estimate rainfall rate and parameters of the drop size distribution once correction for cloud water attenuation is made. Employing a stratiform storm model, calculations of the brightness temperatures at 9.5, 10 and 12 GHz are used to simulate estimates of path-averaged median mass diameter, number concentration and rainfall rate. The results indicate that reasonably accurate estimates of rainfall rate and information on the drop size distribution can be derived over ocean under low to moderate wind speed conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sudheer,, E-mail: sudheer@rrcat.gov.in; Tiwari, P.; Rai, V. N.
The plasmonic responses of silver nanoparticles extracted from silver halide based electron microscope film are investigated. Photo-reduction process is carried out to convert the silver halide grains into the metallic silver. The centrifuge technique is used for separating the silver nanoparticles from the residual solution. Morphological study performed by field emission scanning electron microscope (FESEM) shows that all the nanoparticles have an average diameter of ~120 nm with a high degree of mono dispersion in size. The localized surface plasmon resonance (LSPR) absorption peak at ~537 nm confirms the presence of large size silver nanoparticles.
Improved community model for social networks based on social mobility
NASA Astrophysics Data System (ADS)
Lu, Zhe-Ming; Wu, Zhen; Luo, Hao; Wang, Hao-Xian
2015-07-01
This paper proposes an improved community model for social networks based on social mobility. The relationship between the group distribution and the community size is investigated in terms of communication rate and turnover rate. The degree distributions, clustering coefficients, average distances and diameters of networks are analyzed. Experimental results demonstrate that the proposed model possesses the small-world property and can reproduce social networks effectively and efficiently.
Alloying-Element Loss during High-Temperature Processing of a Nickel-Base Superalloy (Preprint)
2013-01-01
precipitates, and the fine white/gray particles are carbides and borides . ............................................. 23 Figure 2. Aluminum...comparable size, and submicron carbides and borides . A fifteen-minute heat treatment at the subsolvus temperature used in the present work (i.e...precipitates, and ~0.3 volume pct. of carbides and borides with an average diameter of ~0.3 m (Figure 1) [5, 6]. B. Procedures To establish the
Thermal and ultrasonic influence in the formation of nanometer scale hydroxyapatite bio-ceramic
Poinern, GJE; Brundavanam, R; Le, X Thi; Djordjevic, S; Prokic, M; Fawcett, D
2011-01-01
Hydroxyapatite (HAP) is a widely used biocompatible ceramic in many biomedical applications and devices. Currently nanometer-scale forms of HAP are being intensely investigated due to their close similarity to the inorganic mineral component of the natural bone matrix. In this study nano-HAP was prepared via a wet precipitation method using Ca(NO3)2 and KH2PO4 as the main reactants and NH4OH as the precipitator under ultrasonic irradiation. The Ca/P ratio was set at 1.67 and the pH was maintained at 9 during the synthesis process. The influence of the thermal treatment was investigated by using two thermal treatment processes to produce ultrafine nano-HAP powders. In the first heat treatment, a conventional radiant tube furnace was used to produce nano-particles with an average size of approximately 30 nm in diameter, while the second thermal treatment used a microwave-based technique to produce particles with an average diameter of 36 nm. The crystalline structure and morphology of all nanoparticle powders produced were investigated using X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), and Fourier transform infrared spectroscopy (FT-IR). Both thermal techniques effectively produced ultrafine powders with similar crystalline structure, morphology and particle sizes. PMID:22114473
NASA Technical Reports Server (NTRS)
1986-01-01
This 'family portrait' of Uranus' five largest moons was compiled from images sent back Jan. 20, 1986, by the Voyager 2 spacecraft. The pictures were taken through a clear filter from distances of 5.0 million to 6.1 million kilometers (3.1 million to 3.8 million miles). In this comparison, we see the relative sizes and relativities of the satellites. From left, in order of increasing distance from the planet, they are Miranda, Ariel, Umbriel, Titania and Oberon. The two largest, Oberon and Titania, are about half the size of Earth's Moon, or roughly, 1,600 kilometers (1,000 miles) in diameter. Miranda, smallest of the five, has about one-quarter to one-third the diameter. Even in these distant views, the satellites exhibit distinct differences in appearance. On average, Oberon and Titania reflect about 20 percent of the sunlight, Umbriel about 12 percent, Ariel and Miranda about 30 percent. Ariel shows the largest contrast on its surface, with the brightest areas about 25 percent. All five satellites show only slight color variations on their surfaces, with their average color being very nearly gray. The best views of the satellites will be obtained Jan. 24, the day of closest approach. The Voyager project is managed for NASA by the Jet Propulsion Laboratory.
Process for producing silicon nitride based articles of high fracture toughness and strength
Huckabee, Marvin; Buljan, Sergej-Tomislav; Neil, Jeffrey T.
1991-01-01
A process for producing a silicon nitride-based article of improved fracture toughness and strength. The process involves densifying to at least 98% of theoretical density a mixture including (a) a bimodal silicon nitride powder blend consisting essentially of about 10-30% by weight of a first silicon nitride powder of an average particle size of about 0.2 .mu.m and a surface area of about 8-12 m.sup.2 /g, and about 70-90% by weight of a second silicon nitride powder of an average particle size of about 0.4-0.6 .mu.m and a surface area of about 2-4 m.sup.2 /g, (b) about 10-50 percent by volume, based on the volume of the densified article, of refractory whiskers or fibers having an aspect ratio of about 3-150 and having an equivalent diameter selected to produce in the densified article an equivalent diameter ratio of the whiskers or fibers to grains of silicon nitride of greater than 1.0, and (c) an effective amount of a suitable oxide densification aid. Optionally, the mixture may be blended with a binder and injection molded to form a green body, which then may be densified by, for example, hot isostatic pressing.
Process for producing silicon nitride based articles of high fracture toughness and strength
Huckabee, M.; Buljan, S.T.; Neil, J.T.
1991-09-10
A process for producing a silicon nitride-based article of improved fracture toughness and strength is disclosed. The process involves densifying to at least 98% of theoretical density a mixture including (a) a bimodal silicon nitride powder blend consisting essentially of about 10-30% by weight of a first silicon nitride powder of an average particle size of about 0.2 [mu]m and a surface area of about 8-12 m[sup 2]/g, and about 70-90% by weight of a second silicon nitride powder of an average particle size of about 0.4-0.6 [mu]m and a surface area of about 2-4 m[sup 2]/g, (b) about 10-50 percent by volume, based on the volume of the densified article, of refractory whiskers or fibers having an aspect ratio of about 3-150 and having an equivalent diameter selected to produce in the densified article an equivalent diameter ratio of the whiskers or fibers to grains of silicon nitride of greater than 1.0, and (c) an effective amount of a suitable oxide densification aid. Optionally, the mixture may be blended with a binder and injection molded to form a green body, which then may be densified by, for example, hot isostatic pressing.
Huckabee, M.L.; Buljan, S.T.; Neil, J.T.
1991-09-17
A powder mixture and a green body for producing a silicon nitride-based article of improved fracture toughness and strength are disclosed. The powder mixture includes (a) a bimodal silicon nitride powder blend consisting essentially of about 10-30% by weight of a first silicon nitride powder of an average particle size of about 0.2 [mu]m and a surface area of about 8-12m[sup 2]g, and about 70-90% by weight of a second silicon nitride powder of an average particle size of about 0.4-0.6 [mu]m and a surface area of about 2-4 m[sup 2]/g, (b) about 10-50 percent by volume, based on the volume of the densified article, of refractory whiskers or fibers having an aspect ratio of about 3-150 and having an equivalent diameter selected to produce in the densified article an equivalent diameter ratio of the whiskers or fibers to grains of silicon nitride of greater than 1.0, and (c) an effective amount of a suitable oxide densification aid. The green body is formed from the powder mixture, an effective amount of a suitable oxide densification aid, and an effective amount of a suitable organic binder. No Drawings
Huckabee, Marvin L.; Buljan, Sergej-Tomislav; Neil, Jeffrey T.
1991-01-01
A powder mixture and a green body for producing a silicon nitride-based article of improved fracture toughness and strength. The powder mixture includes 9a) a bimodal silicon nitride powder blend consisting essentially of about 10-30% by weight of a first silicon mitride powder of an average particle size of about 0.2 .mu.m and a surface area of about 8-12m.sup.2 g, and about 70-90% by weight of a second silicon nitride powder of an average particle size of about 0.4-0.6 .mu.m and a surface area of about 2-4 m.sup.2 /g, (b) about 10-50 percent by volume, based on the volume of the densified article, of refractory whiskers or fibers having an aspect ratio of about 3-150 and having an equivalent diameter selected to produce in the densified articel an equivalent diameter ratio of the whiskers or fibers to grains of silicon nitride of greater than 1.0, and (c) an effective amount of a suitable oxide densification aid. The green body is formed from the powder mixture, an effective amount of a suitable oxide densification aid, and an effective amount of a suitable organic binder.
NASA Astrophysics Data System (ADS)
Elkatlawy, Saeid; Gomariz, María.; Soto-Sánchez, Cristina; Martínez Navarrete, Gema; Fernández, Eduardo; Fimia, Antonio
2014-05-01
In this paper we report on the use of digital holographic microscopy for 3D real time imaging of cultured neurons and neural networks, in vitro. Digital holographic microscopy is employed as an assessment tool to study the biophysical origin of neurodegenerative diseases. Our study consists in the morphological characterization of the axon, dendrites and cell bodies. The average size and thickness of the soma were 21 and 13 μm, respectively. Furthermore, the average size and diameter of some randomly selected neurites were 4.8 and 0.89 μm, respectively. In addition, the spatiotemporal growth process of cellular bodies and extensions was fitted to by a non-linear behavior of the nerve system. Remarkably, this non-linear process represents the relationship between the growth process of cellular body with respect to the axon and dendrites of the neurons.
Centrifugal Pump Effect on Average Particle Diameter of Oil-Water Emulsion
NASA Astrophysics Data System (ADS)
Morozova, A.; Eskin, A.
2017-11-01
In this paper we review the process of oil-water emulsion particles fragmentation in a turbulent flow created by a centrifugal pump. We examined the influence of time necessary for oil-water emulsion preparation on the particle size of oil products and the dependence of a centrifugal pump emulsifying capacity on the initial emulsion dispersion. The investigated emulsion contained the brand fuel oil M-100 and tap water; it was sprayed with a nozzle in a gas-water flare. After preparation of the emulsion, the centrifugal pump was turned on and the emulsion samples were taken before and after the pump passing in 15, 30 and 45 minutes of spraying. To determine the effect the centrifugal pump has on the dispersion of the oil-water emulsion, the mean particle diameter of the emulsion particles was determined by the optical and microscopic method before and after the pump passing. A dispersion analysis of the particles contained in the emulsion was carried out by a laser diffraction analyzer. By analyzing the pictures of the emulsion samples, it was determined that after the centrifugal pump operation a particle size of oil products decreases. This result is also confirmed by the distribution of the obtained analyzer where the content of fine particles with a diameter less than 10 μm increased from 12% to 23%. In case of increasing emulsion preparation time, a particle size of petroleum products also decreases.
NASA Astrophysics Data System (ADS)
Wu, Jing; Fang, Jinghuai; Cheng, Mingfei; Gong, Xiao
2016-12-01
In our work, large-scale silver NPs (nanoparticles) are successfully synthesized on zinc foils with controllable size by regulating the temperature of the displacement reaction. Our results show that when the temperature is 70 °C, the average size of silver NPs is approximately 88 nm in diameter, and they exhibit the strongest SERS activity. The gap between nanoparticles is simultaneously regulated as near as possible, which produces abundant "hot spots" and nanogaps. Crystal violet (CV) was used as probe molecules, and the SERS signals show that the values of relative standard deviation in the intensity of the main vibration modes are less than 10%, demonstrating excellent reproducibility of the silver NPs. Furthermore, the high surface-average enhancement factor of 3.86 × 107 is achieved even when the concentration of CV is 10-7 M, which is sufficient for single-molecule detection. We believe that this low cost and rapid route would get wide applications in chemical synthesis.
Lyke, Stephen D; Voelz, David G; Roggemann, Michael C
2009-11-20
The probability density function (PDF) of aperture-averaged irradiance fluctuations is calculated from wave-optics simulations of a laser after propagating through atmospheric turbulence to investigate the evolution of the distribution as the aperture diameter is increased. The simulation data distribution is compared to theoretical gamma-gamma and lognormal PDF models under a variety of scintillation regimes from weak to strong. Results show that under weak scintillation conditions both the gamma-gamma and lognormal PDF models provide a good fit to the simulation data for all aperture sizes studied. Our results indicate that in moderate scintillation the gamma-gamma PDF provides a better fit to the simulation data than the lognormal PDF for all aperture sizes studied. In the strong scintillation regime, the simulation data distribution is gamma gamma for aperture sizes much smaller than the coherence radius rho0 and lognormal for aperture sizes on the order of rho0 and larger. Examples of how these results affect the bit-error rate of an on-off keyed free space optical communication link are presented.
Pediatric chest and abdominopelvic CT: organ dose estimation based on 42 patient models.
Tian, Xiaoyu; Li, Xiang; Segars, W Paul; Paulson, Erik K; Frush, Donald P; Samei, Ehsan
2014-02-01
To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. The institutional review board approved this HIPAA-compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0-16 years; weight range, 2-80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDI(vol)). The relationships between CTDI(vol)-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. For organs within the image coverage, CTDI(vol)-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R(2) > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%-32%) mainly because of the effect of overranging. It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDI(vol). These CTDI(vol)-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice. © RSNA, 2013.
Technical note: estimating absorbed doses to the thyroid in CT.
Huda, Walter; Magill, Dennise; Spampinato, Maria V
2011-06-01
To describe a method for estimating absorbed doses to the thyroid in patients undergoing neck CT examinations. Thyroid doses in anthropomorphic phantoms were obtained for all 23 scanner dosimetry data sets in the ImPACT CT patient dosimetry calculator. Values of relative thyroid dose [R(thy)(L)], defined as the thyroid dose for a given scan length (L) divided by the corresponding thyroid dose for a whole body scan, were determined for neck CT scans. Ratios of the maximum thyroid dose to the corresponding CTDI(vol) and [D'(thy)], were obtained for two phantom diameters. The mass-equivalent water cylinder of any patient can be derived from the neck cross-sectional area and the corresponding average Hounsfield Unit, and compared to the 16.5-cm diameter water cylinder that models the ImPACT anthropomorphic phantom neck. Published values of relative doses in water cylinders of varying diameter were used to adjust thyroid doses in the anthropomorphic phantom to those of any sized patient. Relative thyroid doses R(thy)(L) increase to unity with increasing scan length and with very small difference between scanners. A 10-cm scan centered on the thyroid would result in a dose that is, nearly 90% of the thyroid dose from a whole body scan when performed using the constant radiographic techniques. At 120 kV, the average value of D'(thy) for the 16-cm diameter was 1.17 +/- 0.05 and was independent of CT vendor and year of CT scanner, and choice of x-ray tube voltage. The corresponding average value of D'(thy) in the 32-cm diameter phantom was 2.28 +/- 0.22 and showed marked variations depending on vendor, year of introduction into clinical practice as well as x-ray tube voltage. At 120 kV, a neck equivalent to a 10-cm diameter cylinder of water would have thyroid doses 36% higher than those in the ImPACT phantom, whereas a neck equivalent to a 25-cm cylinder diameter would have thyroid doses 35% lower. Patient thyroid doses can be estimated by taking into account the amount of radiation used to perform the CT examination (CTDI(vol)) and accounting for scan length and patient anatomy (i.e., neck diameter) at the thyroid location.
Injectable and porous PLGA microspheres that form highly porous scaffolds at body temperature.
Qutachi, Omar; Vetsch, Jolanda R; Gill, Daniel; Cox, Helen; Scurr, David J; Hofmann, Sandra; Müller, Ralph; Quirk, Robin A; Shakesheff, Kevin M; Rahman, Cheryl V
2014-12-01
Injectable scaffolds are of interest in the field of regenerative medicine because of their minimally invasive mode of delivery. For tissue repair applications, it is essential that such scaffolds have the mechanical properties, porosity and pore diameter to support the formation of new tissue. In the current study, porous poly(dl-lactic acid-co-glycolic acid) (PLGA) microspheres were fabricated with an average size of 84±24μm for use as injectable cell carriers. Treatment with ethanolic sodium hydroxide for 2min was observed to increase surface porosity without causing the microsphere structure to disintegrate. This surface treatment also enabled the microspheres to fuse together at 37°C to form scaffold structures. The average compressive strength of the scaffolds after 24h at 37°C was 0.9±0.1MPa, and the average Young's modulus was 9.4±1.2MPa. Scaffold porosity levels were 81.6% on average, with a mean pore diameter of 54±38μm. This study demonstrates a method for fabricating porous PLGA microspheres that form solid porous scaffolds at body temperature, creating an injectable system capable of supporting NIH-3T3 cell attachment and proliferation in vitro. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Suprascarpal fat pad thickness may predict venous drainage patterns in abdominal wall flaps.
Bast, John; Pitcher, Austin A; Small, Kevin; Otterburn, David M
2016-02-01
Abdominal wall flaps are routinely used in reconstructive procedures. In some patients inadequate venous drainage from the deep vein may cause fat necrosis or flap failure. Occasionally the superficial inferior epigastric vessels (SIEV) are of sufficient size to allow for microvascular revascularization. This study looked at the ratio of the sub- and suprascarpal fat layers, the number of deep system perforators, and SIEV diameter to determine any correlation of the fat topography and SIEV. 50 abdominal/pelvic CT angiograms (100 hemiabdomens) were examined in women aged 34-70 years for number of perforators, SIEV diameter, and fat pad thickness above and below Scarpa's fascia. Data was analyzed using multivariate model. The average suprascarpal and subscarpal layers were 18.6 ± 11.5 mm and 6.2 ± 7.2 mm thick, respectively. The average SIEV diameter was 2.06 ± 0.81 mm and the average number of perforators was 2.09 ± 1.03 per hemiabdomen. Hemiabdomens with suprascarpal thickness>23 mm had greater SIEV diameter [2.69 mm vs. 1.8 mm (P < 0.0001)] The fat layer thickness did not correlate with the number of perforators. Neither subscarpal fat thickness nor suprascarpal-to-subscarpal fat layer thickness correlated significantly with SIEV caliber or number of perforators in multivariate model. Suprascarpal fat pad thicker than 23 mm had larger SIEVs irrespective of the number of deep system perforators. This may indicate a cohort of patients at risk of venous congestion from poor venous drainage if only the deep system is revascularized. We recommend harvesting the SIEV in patients with suprascarpal fat pad >23 mm to aid in superficial drainage. © 2015 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Rezaei, Farzaneh; Richard, Tom L.; Logan, Bruce E.
Microbial fuel cells (MFCs) produce bioelectricity from a wide variety of organic and inorganic substrates. Chitin can be used as a slowly degrading substrate in MFCs and thus as a long-term fuel to sustain power by these devices in remote locations. However, little is known about the effects of particle size on power density and length of the power cycle (longevity). We therefore examined power generation from chitin particles sieved to produce three average particle sizes (0.28, 0.46 and 0.78 mm). The longevity increased from 9 to 33 days with an increase in the particle diameter from 0.28 to 0.78 mm. Coulombic efficiency also increased with particle size from 18% to 56%. The maximum power density was lower for the largest (0.78 mm) particles (176 mW m -2), with higher power densities for the 0.28 mm (272 mW m -2) and 0.46 mm (252 mW m -2) particle sizes. The measured lifetimes of these particles scaled with particle diameter to the 1.3 power. Application of a fractal dissolution model indicates chitin particles had a three-dimensional fractal dimension between 2 and 2.3. These results demonstrate particles can be used as a sustainable fuel in MFCs, but that particle sizes will need to be controlled to achieve desired power levels.
Superparamagnetic properties of carbon nanotubes filled with NiFe{sub 2}O{sub 4} nanoparticles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stojak Repa, K.; Israel, D.; Phan, M. H., E-mail: phanm@usf.edu, E-mail: sharihar@usf.edu
2015-05-07
Multi walled carbon nanotubes (MWCNTs) were successfully synthesized using custom-made 80 nm pore-size alumina templates, and were uniformly filled with nickel ferrite (NFO) nanoparticles of 7.4 ± 1.7 nm diameter using a novel magnetically assisted capillary action method. X-ray diffraction confirmed the inverse spinel phase for the synthesized NFO. Transmission electron microscopy confirms spherical NFO nanoparticles with an average diameter of 7.4 nm inside MWCNTs. Magnetometry indicates that both NFO and NFO-filled MWCNTs present a blocking temperature around 52 K, with similar superparamagnetic-like behavior, and weak dipolar interactions, giving rise to a super-spin-glass-like behavior at low temperatures. These properties along with the uniformity of sub-100 nm structuresmore » and the possibility of tunable magnetic response in variable diameter carbon nanotubes make them ideal for advanced biomedical and microwave applications.« less
Kravchik, T; Oved, S; Paztal-Levy, O; Pelled, O; Gonen, R; German, U; Tshuva, A
2008-01-01
Inhalation is the main route of internal exposure to radioactive aerosols in the nuclear industry. To assess the radiation dose from the intake of these aerosols, it is necessary to know their physical (aerodynamic diameter distribution) and chemical (dissolution rate in extracellular lung fluid) characteristics. Air samples were taken from the uranium processing plant at the Nuclear Research Center, Negev. Measurements of aerodynamic diameter distribution using a cascade impactor indicated an average activity median aerodynamic diameter value close to 5 microm, in accordance with the recent recommended values of International Commission on Radiological Protection (ICRP) model. Solubility profiles of these aerosols were determined by performing in vitro solubility tests over 100 d in a simultant solution of the extracellular fluid. The tests indicated that the uranium aerosols should be assigned to an absorption between Types M and S (as defined by the ICRP Publication 66 model).
NASA Astrophysics Data System (ADS)
Hayati, Alfiah; Pratiwi, Hanna; Khoiriyah, Inayatul; Winarni, Dwi; Sugiharto
2017-06-01
This study was aimed to determine the effect of cadmium on testicles and kidney structure of Oreochromis niloticus in different salinity. Twenty-seven Oreochromis niloticus at age of 5±0.5 months with average size 11±1 cm and average weight 250±50 g were used and divided into nine treatment groups with variations in salinity (0, 5 and 10 ‰) and cadmium levels (0, 2.5, and 5 ppm). After two weeks of treatment periods, testicles and kidney was collected and then processed into histological slide. Result showed that cadmium and salinity variations caused change in diameter of seminiferous tubules in the testicles. Kidney structure also showing various damage such as necrosis and inflammation from groups treated with various concentration of salinity and cadmium. Smallest diameter of seminiferous tubules of the testicles and the highest percentage necrosis and inflammation of kidney was found from salinity:cadmium = 0‰ : 5 ppm treatment.
NASA Astrophysics Data System (ADS)
Zhu, G. Y.; Lin, C. T.; Chen, J. M.; Lei, D. M.; Zhu, G. X.
2018-01-01
Green grass fragrance has been widely used in many fields. However, fragrances are volatile compounds that do not last long. In order to prolong its odor, nanocapsules encapsulated green grass fragrance were prepared. The paper deals with the preparation of green grass fragrance nanocapsules by emulsion polymerization. N-butylcyanoacrylate (BCA) with excellent biocompatibility and biodegradability was used as encapsulant. The nanocapsule suspension systems were characterized and its stability was investigated. The physicochemical properties of polymeric nanocapsules (average diameter and polydispersity) were evaluated as a function of time to assess the system stability. The result showed that the system (containing 0.8% of green grass fragrance, with a polydispersity index (PDI) near 0.1 and an average diameter in the range of 20-30 nm) was an ideal state and relatively stable. Besides, the distinction of stability of three nanocapsule suspensions with different green grass fragrance content was also obvious from scanning electron microscopy (SEM).
Seed mediated synthesis of highly mono-dispersed gold nanoparticles in the presence of hydroquinone
NASA Astrophysics Data System (ADS)
Kumar, Dhiraj; Mutreja, Isha; Sykes, Peter
2016-09-01
Gold nanoparticles (AuNPs) are being studied for several biomedical applications, including drug delivery, biomedical imaging, contrast agents and tumor targeting. The synthesis of nanoparticles with a narrow size distribution is critical for these applications. We report the synthesis of highly mono-dispersed AuNPs by a seed mediated approach, in the presence of tri-sodium citrate and hydroquinone (HQ). AuNPs with an average size of 18 nm were used for the synthesis of highly mono-dispersed nanocrystals of an average size 40 nm, 60 nm, 80 nm and ˜100 nm; but the protocol is not limited to these sizes. The colloidal gold was subjected to UV-vis absorbance spectroscopy, showing a red shift in lambda max wavelength, peaks at 518.47 nm, 526.37 nm, 535.73 nm, 546.03 nm and 556.50 nm for AuNPs seed (18 nm), 40 nm, 60 nm, 80 nm and ˜100 nm respectively. The analysis was consistent with dynamic light scattering and electron microscopy. Hydrodynamic diameters measured were 17.6 nm, 40.8 nm, 59.8 nm, 74.1 nm, and 91.4 nm (size by dynamic light scattering—volume %); with an average poly dispersity index value of 0.088, suggesting mono-dispersity in the size distribution, which was also confirmed by transmission electron microscopy analysis. The advantage of a seed mediated approach is a multi-step growth of nanoparticle size that enables us to control the number of nanoparticles in the suspension, for size ranging from 24.5 nm to 95.8 nm. In addition, the HQ-based synthesis of colloidal nanocrystals allowed control of the particle size and size distribution by tailoring either the number of seeds, amount of gold precursor or reducing agent (HQ) in the final reaction mixture.
Massillon-JL, Guerda; Cueva-Prócel, Diego; Díaz-Aguirre, Porfirio; Rodríguez-Ponce, Miguel; Herrera-Martínez, Flor
2013-01-01
This work investigated the suitability of passive dosimeters for reference dosimetry in small fields with acceptable accuracy. Absorbed dose to water rate was determined in nine small radiation fields with diameters between 4 and 35 mm in a Leksell Gamma Knife (LGK) and a modified linear accelerator (linac) for stereotactic radiosurgery treatments. Measurements were made using Gafchromic film (MD-V2-55), alanine and thermoluminescent (TLD-100) dosimeters and compared with conventional dosimetry systems. Detectors were calibrated in terms of absorbed dose to water in 60Co gamma-ray and 6 MV x-ray reference (10×10 cm2) fields using an ionization chamber calibrated at a standards laboratory. Absorbed dose to water rate computed with MD-V2-55 was higher than that obtained with the others dosimeters, possibly due to a smaller volume averaging effect. Ratio between the dose-rates determined with each dosimeter and those obtained with the film was evaluated for both treatment modalities. For the LGK, the ratio decreased as the dosimeter size increased and remained constant for collimator diameters larger than 8 mm. The same behaviour was observed for the linac and the ratio increased with field size, independent of the dosimeter used. These behaviours could be explained as an averaging volume effect due to dose gradient and lack of electronic equilibrium. Evaluation of the output factors for the LGK collimators indicated that, even when agreement was observed between Monte Carlo simulation and measurements with different dosimeters, this does not warrant that the absorbed dose to water rate in the field was properly known and thus, investigation of the reference dosimetry should be an important issue. These results indicated that alanine dosimeter provides a high degree of accuracy but cannot be used in fields smaller than 20 mm diameter. Gafchromic film can be considered as a suitable methodology for reference dosimetry. TLD dosimeters are not appropriate in fields smaller than 10 mm diameters. PMID:23671677
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen,B.; Miller, E.; Miller, L.
2007-01-01
Methyl methacrylate resins with identical average pore diameter (250 {angstrom}) and surface area (500 m{sup 2}/g) but with varied particle size (35 to 560-710 {mu}m) were employed to study how immobilization resin particle size influences Candida antarctica Lipase B (CALB) loading, fraction of active sites, and catalytic properties for polyester synthesis. CALB adsorbed more rapidly on smaller beads. Saturation occurred in less than 30 s and 48 h for beads with diameters 35 and 560-710 {mu}m, respectively. Linearization of adsorption isotherm data by the Scatchard analysis showed for the 35 {mu}m resin that: (1) CALB loading at saturation was wellmore » below that required to form a monolayer and fully cover the support surface and (2) CALB has a high affinity for this resin surface. Infrared microspectroscopy showed that CALB forms protein loading fronts for resins with particle sizes 560-710 and 120 {mu}m. In contrast, CALB appears evenly distributed throughout 35 {mu}m resins. By titration with p-nitrophenyl n-hexyl phosphate (MNPHP), the fraction of active CALB molecules adsorbed onto resins was <50% which was not influenced by particle size. The fraction of active CALB molecules on the 35 {mu}m support increased from 30 to 43% as enzyme loading was increased from 0.9 to 5.7% (w/w) leading to increased activity for {epsilon}-caprolactone ({epsilon}-CL) ring-opening polymerization. At about 5% w/w CALB loading, by decreasing the immobilization support diameter from 560-710 to 120, 75, and 35 {mu}m, conversion of {epsilon}-CL % to polyester increased (20 to 36, 42, and 61%, respectively, at 80 min). Similar trends were observed for condensation polymerizations between 1,8-octanediol and adipic acid.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, Yung-Sung; Kenoyer, Judson L.; Guilmette, Raymond A.
2009-03-01
The Capstone Depleted Uranium (DU) Aerosol Study, which generated and characterized aerosols containing depleted uranium from perforation of armored vehicles with large-caliber DU penetrators, incorporated a sampling protocol to evaluated particle size distributions. Aerosol particle size distribution is an important parameter that influences aerosol transport and deposition processes as well as the dosimetry of the inhaled particles. These aerosols were collected on cascade impactor substrates using a pre-established time sequence following the firing event to analyze the uranium concentration and particle size of the aerosols as a function of time. The impactor substrates were analyzed using beta spectrometry, and themore » derived uranium content of each served as input to the evaluation of particle size distributions. Activity median aerodynamic diameters (AMADs) of the particle size distributions were evaluated using unimodal and bimodal models. The particle size data from the impactor measurements was quite variable. Most size distributions measured in the test based on activity had bimodal size distributions with a small particle size mode in the range of between 0.2 and 1.2 um and a large size mode between 2 and 15 um. In general, the evolution of particle size over time showed an overall decrease of average particle size from AMADs of 5 to 10 um shortly after perforation to around 1 um at the end of the 2-hr sampling period. The AMADs generally decreased over time because of settling. Additionally, the median diameter of the larger size mode decreased with time. These results were used to estimate the dosimetry of inhaled DU particles.« less
An aftereffect of adaptation to mean size
Corbett, Jennifer E.; Wurnitsch, Nicole; Schwartz, Alex; Whitney, David
2013-01-01
The visual system rapidly represents the mean size of sets of objects. Here, we investigated whether mean size is explicitly encoded by the visual system, along a single dimension like texture, numerosity, and other visual dimensions susceptible to adaptation. Observers adapted to two sets of dots with different mean sizes, presented simultaneously in opposite visual fields. After adaptation, two test patches replaced the adapting dot sets, and participants judged which test appeared to have the larger average dot diameter. They generally perceived the test that replaced the smaller mean size adapting set as being larger than the test that replaced the larger adapting set. This differential aftereffect held for single test dots (Experiment 2) and high-pass filtered displays (Experiment 3), and changed systematically as a function of the variance of the adapting dot sets (Experiment 4), providing additional support that mean size is adaptable, and therefore explicitly encoded dimension of visual scenes. PMID:24348083
NASA Astrophysics Data System (ADS)
Matsumoto, Toru; Hasegawa, S.; Nakao, S.; Sakai, M.; Yurimoto, H.
2018-03-01
We investigated impact crater structures on regolith particles from asteroid Itokawa using scanning electron microscopy. We observed the surfaces of 51 Itokawa particles, ranging from 15 μm to 240 μm in size. Craters with average diameters ranging from 10 nm to 2.8 μm were identified on 13 Itokawa particles larger than 80 μm. We examined the abundance, spatial distribution, and morphology of approximately 900 craters on six Itokawa particles. Craters with sizes in excess of 200 nm are widely dispersed, with spatial densities from 2.6 μm2 to 4.5 μm2; a fraction of the craters was locally concentrated with a density of 0.1 μm2. The fractal dimension of the cumulative crater diameters ranges from 1.3 to 2.3. Craters of several tens of nanometers in diameter exhibit pit and surrounding rim structures. Craters of more than 100 nm in diameter commonly have melted residue at their bottom. These morphologies are similar to those of submicrometer-sized craters on lunar regolith. We estimated the impactor flux on Itokawa regolith-forming craters, assuming that the craters were accumulated during direct exposure to the space environment for 102 to 104 yr. The range of impactor flux onto Itokawa particles is estimated to be at least one order of magnitude higher than the interplanetary dust flux and comparable to the secondary impact flux on the Moon. This indicates that secondary ejecta impacts are probably the dominant cratering process in the submicrometer range on Itokawa regolith particles, as well as on the lunar surface. We demonstrate that secondary submicrometer craters can be produced anywhere in centimeter- to meter-sized depressions on Itokawa's surface through primary interplanetary dust impacts. If the surface unevenness on centimeter to meter scales is a significant factor determining the abundance of submicrometer secondary cratering, the secondary impact flux could be independent of the overall shapes or sizes of celestial bodies, and the secondary impact flux could have similar values on Itokawa and the Moon.
Promotion of artery occlusion in dogs by percutaneous rotational atherectomy.
Hou, Chuan-Ju; Zhang, Duan-Zhen; Wang, Qi-Guang; Cui, Chun-Sheng; Kuang, Li; Chen, Bing; Wang, Yang
2014-07-01
This study aims to offer experimental data and indirect evidences for the application of percutaneous rotational atherectomy to treat patent ductus arteriosus (PDA). Eleven dogs (6 male dogs and 5 female dogs; aged 14-20 months, with an average of 16.7±3.2 months; weight 20-25 kg, with an average of 22.7±2.5 kg) were enrolled in this study. The diameters of the left and right arteries ranged from 3.2 to 4.8 mm (average 3.9±0.6 mm) on percutaneous angiography. Percutaneous rotational atherectomy with proper rotablator (the size was 1-1.5 mm larger than the artery diameter) was performed in the arterial intima. After 4 weeks from percutaneous rotational atherectomy, arteriography was conducted to observe the changes in artery diameter. Then all dogs were sacrificed and the pathologic examination was conducted on the left and right axillary arteries. There were obvious changes with different degrees in 22 arteries, including 8 arteries with complete occlusion and 12 arteries with stenosis (≥2/3, 1/2, and 1/3 stenosis in 4, 4, and 4 arteries, respectively). The occlusion rate was 36.4% and the total effective rate was 90.9%. It was considered failure in other 2 arteries with <1/3 of stenosis. Percutaneous rotational atherectomy of arterial intima can promote the occlusion of arteries. This has provided a new choice for the treatment of PDA. Copyright © 2014 Elsevier Inc. All rights reserved.
Effective solidity in vertical axis wind turbines
NASA Astrophysics Data System (ADS)
Parker, Colin M.; Leftwich, Megan C.
2016-11-01
The flow surrounding vertical axis wind turbines (VAWTs) is investigated using particle imaging velocimetry (PIV). This is done in a low-speed wind tunnel with a scale model that closely matches geometric and dynamic properties tip-speed ratio and Reynolds number of a full size turbine. Previous results have shown a strong dependance on the tip-speed ratio on the wake structure of the spinning turbine. However, it is not clear whether this is a speed or solidity effect. To determine this, we have measured the wakes of three turbines with different chord-to-diameter ratios, and a solid cylinder. The flow is visualized at the horizontal mid-plane as well as the vertical mid-plane behind the turbine. The results are both ensemble averaged and phase averaged by syncing the PIV system with the rotation of the turbine. By keeping the Reynolds number constant with both chord and diameter, we can determine how each effects the wake structure. As these parameters are varied there are distinct changes in the mean flow of the wake. Additionally, by looking at the vorticity in the phase averaged profiles we can see structural changes to the overall wake pattern.
Thin, porous metal sheets and methods for making the same
Liu, Wei; Li, Xiaohong Shari; Canfield, Nathan L.
2015-07-14
Thin, porous metal sheets and methods for forming them are presented to enable a variety of applications and devices. The thin, porous metal sheets are less than or equal to approximately 200 .mu.m thick, have a porosity between 25% and 75% by volume, and have pores with an average diameter less than or equal to approximately 2 .mu.m. The thin, porous metal sheets can be fabricated by preparing a slurry having between 10 and 50 wt % solvent and between 20 and 80 wt % powder of a metal precursor. The average particle size in the metal precursor powder should be between 100 nm and 5 .mu.m.
Hollow proppants and a process for their manufacture
Jones, A.H.; Cutler, R.A.
1985-10-15
Hollow, fine-grained ceramic proppants are less expensive and improve fracture control when compared to conventional proppants (dense alumina, mullite, bauxite, zirconia, etc.). Hollow proppants of the present invention have been fabricated by spray drying, followed by sintering in order to obtain a dense case and a hollow core. These proppants generally have high sphericity and roundness (Krumbein sphericity and roundness greater than 0.8), have diameters on average between 2,250 and 125 [mu]m, depending on proppant size required, and have strength equal to or greater than that of sand. The hollow core, the size of which can be controlled, permits better fracture control in hydraulic fracturing treatments since the proppant can be transported in lower viscosity fluids. Hollow proppants produced at the same cost/weight as conventional proppants also provide for lower costs, since less weight is required to fill the same volume. The fine-grained (preferably less than 5 [mu]m in diameter) ceramic case provides the strength necessary to withstand closure stresses and prevent crushing. 6 figs.
Hollow proppants and a process for their manufacture
Jones, Arfon H.; Cutler, Raymond A.
1985-01-01
Hollow, fine-grained ceramic proppants are less expensive and improve fracture control when compared to conventional proppants (dense alumina, mullite, bauxite, zirconia, etc.). Hollow proppants of the present invention have been fabricated by spray drying, followed by sintering in order to obtain a dense case and a hollow core. These proppants generally have high sphericity and roundness (Krumbein sphericity and roundness greater than 0.8), have diameters on average between 2250 and 125 .mu.m, depending on proppant size required, and have strength equal to or greater than that of sand. The hollow core, the size of which can be controlled, permits better fracture control in hydraulic fracturing treatments since the proppant can be transported in lower viscosity fluids. Hollow proppants produced at the same cost/weight as conventional proppants also provide for lower costs, since less weight is required to fill the same volume. The fine-grained (preferably less than 5 .mu.m in diameter) ceramic case provides the strength necessary to withstand closure stresses and prevent crushing.
Impact craters and Venus resurfacing history
NASA Technical Reports Server (NTRS)
Phillips, Roger J.; Raubertas, Richard F.; Arvidson, Raymond E.; Sarkar, Ila C.; Herrick, Robert R.; Izenberg, Noam; Grimm, Robert E.
1992-01-01
The history of resurfacing by tectonism and volcanism on Venus is reconstructed by means of an analysis of Venusian impact crater size-frequency distributions, locations, and preservation states. An atmospheric transit model for meteoroids demonstrates that for craters larger than about 30 km, the size-frequency distribution is close to the atmosphere-free case. An age of cessation of rapid resurfacing of about 500 Ma is obtained. It is inferred that a range of surface ages are recorded by the impact crater population; e.g., the Aphrodite zone is relatively young. An end-member model is developed to quantify resurfacing scenarios. It is argued that Venus has been resurfacing at an average rate of about 1 sq km/yr. Numerical simulations of resurfacing showed that there are two solution branches that satisfy the completely spatially random location restraint for Venusian craters: a is less than 0.0003 (4 deg diameter circle) and a is greater than 0.1 (74 deg diameter circle).
Patient-specific Radiation Dose and Cancer Risk for Pediatric Chest CT
Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Frush, Donald P.
2011-01-01
Purpose: To estimate patient-specific radiation dose and cancer risk for pediatric chest computed tomography (CT) and to evaluate factors affecting dose and risk, including patient size, patient age, and scanning parameters. Materials and Methods: The institutional review board approved this study and waived informed consent. This study was HIPAA compliant. The study included 30 patients (0–16 years old), for whom full-body computer models were recently created from clinical CT data. A validated Monte Carlo program was used to estimate organ dose from eight chest protocols, representing clinically relevant combinations of bow tie filter, collimation, pitch, and tube potential. Organ dose was used to calculate effective dose and risk index (an index of total cancer incidence risk). The dose and risk estimates before and after normalization by volume-weighted CT dose index (CTDIvol) or dose–length product (DLP) were correlated with patient size and age. The effect of each scanning parameter was studied. Results: Organ dose normalized by tube current–time product or CTDIvol decreased exponentially with increasing average chest diameter. Effective dose normalized by tube current–time product or DLP decreased exponentially with increasing chest diameter. Chest diameter was a stronger predictor of dose than weight and total scan length. Risk index normalized by tube current–time product or DLP decreased exponentially with both chest diameter and age. When normalized by DLP, effective dose and risk index were independent of collimation, pitch, and tube potential (<10% variation). Conclusion: The correlations of dose and risk with patient size and age can be used to estimate patient-specific dose and risk. They can further guide the design and optimization of pediatric chest CT protocols. © RSNA, 2011 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101900/-/DC1 PMID:21467251
Patient-specific radiation dose and cancer risk for pediatric chest CT.
Li, Xiang; Samei, Ehsan; Segars, W Paul; Sturgeon, Gregory M; Colsher, James G; Frush, Donald P
2011-06-01
To estimate patient-specific radiation dose and cancer risk for pediatric chest computed tomography (CT) and to evaluate factors affecting dose and risk, including patient size, patient age, and scanning parameters. The institutional review board approved this study and waived informed consent. This study was HIPAA compliant. The study included 30 patients (0-16 years old), for whom full-body computer models were recently created from clinical CT data. A validated Monte Carlo program was used to estimate organ dose from eight chest protocols, representing clinically relevant combinations of bow tie filter, collimation, pitch, and tube potential. Organ dose was used to calculate effective dose and risk index (an index of total cancer incidence risk). The dose and risk estimates before and after normalization by volume-weighted CT dose index (CTDI(vol)) or dose-length product (DLP) were correlated with patient size and age. The effect of each scanning parameter was studied. Organ dose normalized by tube current-time product or CTDI(vol) decreased exponentially with increasing average chest diameter. Effective dose normalized by tube current-time product or DLP decreased exponentially with increasing chest diameter. Chest diameter was a stronger predictor of dose than weight and total scan length. Risk index normalized by tube current-time product or DLP decreased exponentially with both chest diameter and age. When normalized by DLP, effective dose and risk index were independent of collimation, pitch, and tube potential (<10% variation). The correlations of dose and risk with patient size and age can be used to estimate patient-specific dose and risk. They can further guide the design and optimization of pediatric chest CT protocols. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101900/-/DC1. RSNA, 2011
Craters of the Pluto-Charon system
NASA Astrophysics Data System (ADS)
Robbins, Stuart J.; Singer, Kelsi N.; Bray, Veronica J.; Schenk, Paul; Lauer, Tod R.; Weaver, Harold A.; Runyon, Kirby; McKinnon, William B.; Beyer, Ross A.; Porter, Simon; White, Oliver L.; Hofgartner, Jason D.; Zangari, Amanda M.; Moore, Jeffrey M.; Young, Leslie A.; Spencer, John R.; Binzel, Richard P.; Buie, Marc W.; Buratti, Bonnie J.; Cheng, Andrew F.; Grundy, William M.; Linscott, Ivan R.; Reitsema, Harold J.; Reuter, Dennis C.; Showalter, Mark R.; Tyler, G. Len; Olkin, Catherine B.; Ennico, Kimberly S.; Stern, S. Alan; New Horizons Lorri, Mvic Instrument Teams
2017-05-01
NASA's New Horizons flyby mission of the Pluto-Charon binary system and its four moons provided humanity with its first spacecraft-based look at a large Kuiper Belt Object beyond Triton. Excluding this system, multiple Kuiper Belt Objects (KBOs) have been observed for only 20 years from Earth, and the KBO size distribution is unconstrained except among the largest objects. Because small KBOs will remain beyond the capabilities of ground-based observatories for the foreseeable future, one of the best ways to constrain the small KBO population is to examine the craters they have made on the Pluto-Charon system. The first step to understanding the crater population is to map it. In this work, we describe the steps undertaken to produce a robust crater database of impact features on Pluto, Charon, and their two largest moons, Nix and Hydra. These include an examination of different types of images and image processing, and we present an analysis of variability among the crater mapping team, where crater diameters were found to average ± 10% uncertainty across all sizes measured (∼0.5-300 km). We also present a few basic analyses of the crater databases, finding that Pluto's craters' differential size-frequency distribution across the encounter hemisphere has a power-law slope of approximately -3.1 ± 0.1 over diameters D ≈ 15-200 km, and Charon's has a slope of -3.0 ± 0.2 over diameters D ≈ 10-120 km; it is significantly shallower on both bodies at smaller diameters. We also better quantify evidence of resurfacing evidenced by Pluto's craters in contrast with Charon's. With this work, we are also releasing our database of potential and probable impact craters: 5287 on Pluto, 2287 on Charon, 35 on Nix, and 6 on Hydra.
Savini, G; Zanini, M; Carelli, V; Sadun, A A; Ross-Cisneros, F N; Barboni, P
2005-04-01
To investigate the correlation between retinal nerve fibre layer (RNFL) thickness and optic nerve head (ONH) size in normal white subjects by means of optical coherence tomography (OCT). 54 eyes of 54 healthy subjects aged between 15 and 54 underwent peripapillary RNFL thickness measurement by a series of three circular scans with a 3.4 mm diameter (Stratus OCT, RNFL Thickness 3.4 acquisition protocol). ONH analysis was performed by means of six radial scans centred on the optic disc (Stratus OCT, Fast Optic Disc acquisition protocol). The mean RNFL values were correlated with the data obtained by ONH analysis. The superior, nasal, and inferior quadrant RNFL thickness showed a significant correlation with the optic disc area (R = 0.3822, p = 0.0043), (R = 0.3024, p = 0.026), (R = 0.4048, p = 0.0024) and the horizontal disc diameter (R = 0.2971, p = 0.0291), (R = 0.2752, p = 0.044), (R = 0.3970, p = 0.003). The superior and inferior quadrant RNFL thickness was also positively correlated with the vertical disc diameter (R = 0.3774, p = 0.0049), (R = 0.2793, p = 0.0408). A significant correlation was observed between the 360 degrees average RNFL thickness and the optic disc area and the vertical and horizontal disc diameters of the ONH (R = 0.4985, p = 0.0001), (R = 0.4454, p = 0.0007), (R = 0.4301, p = 0.0012). RNFL thickness measurements obtained by Stratus OCT increased significantly with an increase in optic disc size. It is not clear if eyes with large ONHs show a thicker RNFL as a result of an increased amount of nerve fibres or to the shorter distance between the circular scan and the optic disc edge.
Craters of the Pluto-Charon System
NASA Technical Reports Server (NTRS)
Robbins, Stuart J.; Singer, Kelsi N.; Bray, Veronica J.; Schenk, Paul; Lauer, Todd R.; Weaver, Harold A.; Runyon, Kirby; Mckinnon, William B.; Beyer, Ross A.; Porter, Simon;
2016-01-01
NASA's New Horizons flyby mission of the Pluto-Charon binary system and its four moons provided humanity with its first spacecraft-based look at a large Kuiper Belt Object beyond Triton. Excluding this system, multiple Kuiper Belt Objects (KBOs) have been observed for only 20 years from Earth, and the KBO size distribution is unconstrained except among the largest objects. Because small KBOs will remain beyond the capabilities of ground-based observatories for the foreseeable future, one of the best ways to constrain the small KBO population is to examine the craters they have made on the Pluto-Charon system. The first step to understanding the crater population is to map it. In this work, we describe the steps undertaken to produce a robust crater database of impact features on Pluto, Charon, and their two largest moons, Nix and Hydra. These include an examination of different types of images and image processing, and we present an analysis of variability among the crater mapping team, where crater diameters were found to average +/-10% uncertainty across all sizes measured (approx.0.5-300 km). We also present a few basic analyses of the crater databases, finding that Pluto's craters' differential size-frequency distribution across the encounter hemisphere has a power-law slope of approximately -3.1 +/- 0.1 over diameters D approx. = 15-200 km, and Charon's has a slope of -3.0 +/- 0.2 over diameters D approx. = 10-120 km; it is significantly shallower on both bodies at smaller diameters. We also better quantify evidence of resurfacing evidenced by Pluto's craters in contrast with Charon's. With this work, we are also releasing our database of potential and probable impact craters: 5287 on Pluto, 2287 on Charon, 35 on Nix, and 6 on Hydra.
Nanopores creation in boron and nitrogen doped polycrystalline graphene: A molecular dynamics study
NASA Astrophysics Data System (ADS)
Izadifar, Mohammadreza; Abadi, Rouzbeh; Nezhad Shirazi, Ali Hossein; Alajlan, Naif; Rabczuk, Timon
2018-05-01
In the present paper, molecular dynamic simulations have been conducted to investigate the nanopores creation on 10% of boron and nitrogen doped polycrystalline graphene by silicon and diamond nanoclusters. Two types of nanoclusters based on silicon and diamond are used to investigate their effect for the fabrication of nanopores. Therefore, three different diameter sizes of the clusters with five kinetic energies of 10, 50, 100, 300 and 500 eV/atom at four different locations in boron or nitrogen doped polycrystalline graphene nanosheets have been perused. We also study the effect of 3% and 6% of boron doped polycrystalline graphene with the best outcome from 10% of doping. Our results reveal that the diamond cluster with diameter of 2 and 2.5 nm fabricates the largest nanopore areas on boron and nitrogen doped polycrystalline graphene, respectively. Furthermore, the kinetic energies of 10 and 50 eV/atom can not fabricate nanopores in some cases for silicon and diamond clusters on boron doped polycrystalline graphene nanosheets. On the other hand, silicon and diamond clusters fabricate nanopores for all locations and all tested energies on nitrogen doped polycrystalline graphene. The area sizes of nanopores fabricated by silicon and diamond clusters with diameter of 2 and 2.5 nm are close to the actual area size of the related clusters for the kinetic energy of 300 eV/atom in all locations on boron doped polycrystalline graphene. The maximum area and the average maximum area of nanopores are fabricated by the kinetic energy of 500 eV/atom inside the grain boundary at the center of the nanosheet and in the corner of nanosheet with diameters of 2 and 3 nm for silicon and diamond clusters on boron and nitrogen doped polycrystalline graphene.
Apollo 12 Lunar Module exhaust plume impingement on Lunar Surveyor III
NASA Astrophysics Data System (ADS)
Immer, Christopher; Metzger, Philip; Hintze, Paul E.; Nick, Andrew; Horan, Ryan
2011-02-01
Understanding plume impingement by retrorockets on the surface of the Moon is paramount for safe lunar outpost design in NASA's planned return to the Moon for the Constellation Program. Visual inspection, Scanning Electron Microscopy, and surface scanned topology have been used to investigate the damage to the Lunar Surveyor III spacecraft that was caused by the Apollo 12 Lunar Module's close proximity landing. Two parts of the Surveyor III craft returned by the Apollo 12 astronauts, Coupons 2050 and 2051, which faced the Apollo 12 landing site, show that a fine layer of lunar regolith coated the materials and was subsequently removed by the Apollo 12 Lunar Module landing rocket. The coupons were also pitted by the impact of larger soil particles with an average of 103 pits/cm 2. The average entry size of the pits was 83.7 μm (major diameter) × 74.5 μm (minor diameter) and the average estimated penetration depth was 88.4 μm. Pitting in the surface of the coupons correlates to removal of lunar fines and is likely a signature of lunar material imparting localized momentum/energy sufficient to cause cracking of the paint. Comparison with the lunar soil particle size distribution and the optical density of blowing soil during lunar landings indicates that the Surveyor III spacecraft was not exposed to the direct spray of the landing Lunar Module, but instead experienced only the fringes of the spray of soil. Had Surveyor III been exposed to the direct spray, the damage would have been orders of magnitude higher.
Shape, size and multiplicity of main-belt asteroids I. Keck Adaptive Optics survey.
Marchis, F; Kaasalainen, M; Hom, E F Y; Berthier, J; Enriquez, J; Hestroffer, D; Le Mignant, D; de Pater, I
2006-11-01
This paper presents results from a high spatial resolution survey of 33 main-belt asteroids with diameters >40 km using the Keck II Adaptive Optics (AO) facility. Five of these (45 Eugenia, 87 Sylvia, 107 Camilla, 121 Hermione, 130 Elektra) were confirmed to have satellite. Assuming the same albedo as the primary, these moonlets are relatively small (∼5% of the primary size) suggesting that they are fragments captured after a disruptive collision of a parent body or captured ejecta due to an impact. For each asteroid, we have estimated the minimum size of a moonlet that can positively detected within the Hill sphere of the system by estimating and modeling a 2-σ detection profile: in average on the data set, a moonlet located at 2/100 × R(Hill) (1/4 × R(Hill)) with a diameter larger than 6 km (4 km) would have been unambiguously seen. The apparent size and shape of each asteroid was estimated after deconvolution using a new algorithm called AIDA. The mean diameter for the majority of asteroids is in good agreement with IRAS radiometric measurements, though for asteroids with a D < 200 km, it is underestimated on average by 6-8%. Most asteroids had a size ratio that was very close to those determined by lightcurve measurements. One observation of 104 Klymene suggests it has a bifurcated shape. The bi-lobed shape of 121 Hermione described in Marchis et al. [Marchis, F., Hestroffer, D., Descamps, P., Berthier, J., Laver, C., de Pater, I., 2005c. Icarus 178, 450-464] was confirmed after deconvolution. The ratio of contact binaries in our survey, which is limited to asteroids larger than 40 km, is surprisingly high (∼6%), suggesting that a non-single configuration is common in the main-belt. Several asteroids have been analyzed with lightcurve inversions. We compared lightcurve inversion models for plane-of-sky predictions with the observed images (9 Metis, 52 Europa, 87 Sylvia, 130 Elektra, 192 Nausikaa, and 423 Diotima, 511 Davida). The AO images allowed us to determine a unique photometric mirror pole solution, which is normally ambiguous for asteroids moving close to the plane of the ecliptic (e.g., 192 Nausikaa and 52 Europa). The photometric inversion models agree well with the AO images, thus confirming the validity of both the lightcurve inversion method and the AO image reduction technique.
Size ratio correlates with intracranial aneurysm rupture status: a prospective study.
Rahman, Maryam; Smietana, Janel; Hauck, Erik; Hoh, Brian; Hopkins, Nick; Siddiqui, Adnan; Levy, Elad I; Meng, Hui; Mocco, J
2010-05-01
The prediction of intracranial aneurysm (IA) rupture risk has generated significant controversy. The findings of the International Study of Unruptured Intracranial Aneurysms (ISUIA) that small anterior circulation aneurysms (<7 mm) have a 0% risk of subarachnoid hemorrhage in 5 years is difficult to reconcile with other studies that reported a significant portion of ruptured IAs are small. These discrepancies have led to the search for better aneurysm parameters to predict rupture. We previously reported that size ratio (SR), IA size divided by parent vessel diameter, correlated strongly with IA rupture status (ruptured versus unruptured). These data were all collected retrospectively off 3-dimensional angiographic images. Therefore, we performed a blinded prospective collection and evaluation of SR data from 2-dimensional angiographic images for a consecutive series of patients with ruptured and unruptured IAs. We prospectively enrolled 40 consecutive patients presenting to a single institution with either ruptured IA or for first-time evaluation of an incidental IA. Blinded technologists acquired all measurements from 2-dimensional angiographic images. Aneurysm rupture status, location, IA maximum size, and parent vessel diameter were documented. The SR was calculated by dividing the aneurysm size (mm) by the average parent vessel size (mm). A 2-tailed Mann-Whitney test was performed to assess statistical significance between ruptured and unruptured groups. Fisher exact test was used to compare medical comorbidities between the ruptured and unruptured groups. Significant differences between the 2 groups were subsequently tested with logistic regression. SE and probability values are reported. Forty consecutive patients with 24 unruptured and 16 ruptured aneurysms met the inclusion criteria. No significant differences were found in age, gender, smoking status, or medical comorbidities between ruptured and unruptured groups. The average maximum size of the unruptured IAs (6.18 + or - 0.60 mm) was significantly smaller compared with the ruptured IAs (7.91 + or - 0.47 mm; P=0.03), and the unruptured group had significantly smaller SRs (2.57 + or - 0.24 mm) compared with the ruptured group (4.08 + or - 0.54 mm; P<0.01). Logistic regression was used to evaluate the independent predictive value of those variables that achieved significance in univariate analysis (IA maximum size and SR). Using stepwise selection, only SR remained in the final predictive model (OR, 2.12; 95% CI, 1.09 to 4.13). SR, the ratio between aneurysm size and parent artery diameter, can be easily calculated from 2-dimensional angiograms and correlates with IA rupture status on presentation in a blinded analysis. SR should be further studied in a large prospective observational cohort to predict true IA risk of rupture.
NASA Astrophysics Data System (ADS)
Heilbronner, Renée; Kilian, Ruediger
2017-04-01
Grain size analyses are carried out for a number of reasons, for example, the dynamically recrystallized grain size of quartz is used to assess the flow stresses during deformation. Typically a thin section or polished surface is used. If the expected grain size is large enough (10 µm or larger), the images can be obtained on a light microscope, if the grain size is smaller, the SEM is used. The grain boundaries are traced (the process is called segmentation and can be done manually or via image processing) and the size of the cross sectional areas (segments) is determined. From the resulting size distributions, 'the grain size' or 'average grain size', usually a mean diameter or similar, is derived. When carrying out such grain size analyses, a number of aspects are critical for the reproducibility of the result: the resolution of the imaging equipment (light microscope or SEM), the type of images that are used for segmentation (cross polarized, partial or full orientation images, CIP versus EBSD), the segmentation procedure (algorithm) itself, the quality of the segmentation and the mathematical definition and calculation of 'the average grain size'. The quality of the segmentation depends very strongly on the criteria that are used for identifying grain boundaries (for example, angles of misorientation versus shape considerations), on pre- and post-processing (filtering) and on the quality of the recorded images (most notably on the indexing ratio). In this contribution, we consider experimentally deformed Black Hills quartzite with dynamically re-crystallized grain sizes in the range of 2 - 15 µm. We compare two basic methods of segmentations of EBSD maps (orientation based versus shape based) and explore how the choice of methods influences the result of the grain size analysis. We also compare different measures for grain size (mean versus mode versus RMS, and 2D versus 3D) in order to determine which of the definitions of 'average grain size yields the most stable results.
Martinez-Enriquez, Eduardo; Sun, Mengchan; Velasco-Ocana, Miriam; Birkenfeld, Judith; Pérez-Merino, Pablo; Marcos, Susana
2016-07-01
Measurement of crystalline lens geometry in vivo is critical to optimize performance of state-of-the-art cataract surgery. We used custom-developed quantitative anterior segment optical coherence tomography (OCT) and developed dedicated algorithms to estimate lens volume (VOL), equatorial diameter (DIA), and equatorial plane position (EPP). The method was validated ex vivo in 27 human donor (19-71 years of age) lenses, which were imaged in three-dimensions by OCT. In vivo conditions were simulated assuming that only the information within a given pupil size (PS) was available. A parametric model was used to estimate the whole lens shape from PS-limited data. The accuracy of the estimated lens VOL, DIA, and EPP was evaluated by comparing estimates from the whole lens data and PS-limited data ex vivo. The method was demonstrated in vivo using 2 young eyes during accommodation and 2 cataract eyes. Crystalline lens VOL was estimated within 96% accuracy (average estimation error across lenses ± standard deviation: 9.30 ± 7.49 mm3). Average estimation errors in EPP were below 40 ± 32 μm, and below 0.26 ± 0.22 mm in DIA. Changes in lens VOL with accommodation were not statistically significant (2-way ANOVA, P = 0.35). In young eyes, DIA decreased and EPP increased statistically significantly with accommodation (P < 0.001) by 0.14 mm and 0.13 mm, respectively, on average across subjects. In cataract eyes, VOL = 205.5 mm3, DIA = 9.57 mm, and EPP = 2.15 mm on average. Quantitative OCT with dedicated image processing algorithms allows estimation of human crystalline lens volume, diameter, and equatorial lens position, as validated from ex vivo measurements, where entire lens images are available.
Final bubble lengths for aqueous foam coarsened in a horizontal cylinder
NASA Astrophysics Data System (ADS)
Sebag, V.; Roth, A. E.; Durian, D. J.
2011-12-01
We report on length statistics measured for bubbles in the equilibrium bamboo state, achieved by the coarsening of aqueous foam in long cylindrical tubes, such that the soap films are all flat and perpendicular to the axis of the tube. The average bubble length is found to be 0.88 times the tube diameter, independent of variation of the liquid filling fraction by a factor of nearly three. The actual distribution is well-approximated by a shifted Rayleigh form, with a minimum bubble size of 0.28 tube diameters. And, perhaps surprisingly, no correlations are found in the lengths of neighboring bubbles. The observed length distribution agrees with that of Fortes et al. for short bubbles, but not for long bubbles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chebukati, Janetricks N.; Goff, Philip C.; Frederick, Thomas E.
2010-04-09
The morphology and size of hydrated lipid dispersions of bis(monoacylglycero)phosphate (BMP) mixed with varying mole percentages of the ganglioside GM1 were investigated by dynamic light scattering (DLS) and transmission electron microscopy (TEM). Electron paramagnetic resonance (EPR) spectroscopy of these same mixtures, doped at 0.5 mol% with doxyl labeled lipids, was used to investigate acyl-chain packing. Results show that for 20-30% GM1, hydrated BMP:GM1 mixtures spontaneously form small spherical vesicles with diameters {approx}100 nm and a narrow size distribution profile. For other concentrations of GM1, hydrated dispersions with BMP have non-spherical shapes and heterogeneous size profiles, with average vesicle diameters >400more » nm. All samples were prepared at pH 5.5 to mimic the lumen acidity of the late endosome where BMP is an essential component of intraendosomal vesicle budding, lipid sorting and trafficking. These findings indicate that GM1 and BMP under a limited concentration range spontaneously form small vesicles of homogeneous size in an energy independent manner without the need of protein templating. Because BMP is essential for intraendosomal vesicle formation, these results imply that lipid-lipid interactions may play a critical role in the endosomal process of lipid sorting and trafficking.« less
Ovarian follicle dynamics of female Greater Scaup during egg production
Gorman, Kristen B.; Flint, Paul L.; Esler, Daniel N.; Williams, T.D.
2007-01-01
Studies of female waterfowl nutrient reserve use during egg production require a precise understanding of ovarian follicle dynamics to correctly interpret breeding status, and, therefore, derive proper inference. Concerns over numerical declines of North American scaup have increased the need to better understand the role of female condition in reproductive performance. We quantified ovarian follicle dynamics of female Greater Scaup (Aythya marila) breeding on the Yukon–Kuskokwim Delta, Alaska, using a method that accounts for within day variation in follicle size. We considered several models for describing changes in follicle growth with the best supported model estimating the duration of rapid follicle growth (RFG) to be 5.20 ± 0.52 days (±95% confidence intervals) for each developing follicle. Average diameter and dry mass of preovulatory follicles were estimated to be 9.36 mm and 0.26 g, respectively, at the onset of RFG, and these follicle characteristics were 41.47 mm and 15.57 g, respectively, at ovulation. The average diameter of postovulatory follicles immediately following ovulation was estimated to be 17.35 mm, regressing quickly over several days. In addition, we derived predictive equations using diameter and dry mass to estimate the number of days before, and after, ovulation for pre- and postovulatory follicles, as well as an equation to estimate dry mass of damaged follicles. Our results allow precise definition of RFG and nest initiation dates, clutch size, and the daily energetic and nutritional demands of egg production at the individual level. This study provides the necessary foundation for additional work on Greater Scaup reproductive energetics and physiology, and offers an approach for quantifying ovarian follicle dynamics in other species.
Left Atrium Size in Elite Athletes.
Iskandar, Aline; Mujtaba, Mohammad Tokir; Thompson, Paul D
2015-07-01
The goal of this study was to perform a meta-analysis of the published literature to investigate the relationship of high levels of exercise training to left atrial (LA) size. The "athlete's heart" is a series of cardiac adaptations to systematic exercise training and may include LA enlargement. We conducted a systematic review of English-language studies in MEDLINE and Scopus from inception through April 29, 2014, that reported LA size in elite athletes. A total of 54 studies comprising 7,189 elite athletes and 1,375 controls were included. Forty-eight of the 54 studies reported absolute LA diameter in 7,018 athletes and 1,044 controls. Nine of the 54 studies (including 992 athletes and 426 controls) presented LA volume corrected for body surface area. The adjusted weighted mean LA diameter was 4.1 mm greater in athletes overall compared with sedentary controls (p < 0.0001), and LA volume index was 7.0 ml/m(2) greater in athletes than controls (p < 0.01). Compared with controls, LA diameter was 4.6 mm greater in endurance-trained athletes (p < 0.0001), 2.9 mm greater in strength-trained athletes (p < 0.03), 3.5 mm greater in combined strength- and endurance-trained athletes (p < 0.0001), and 4.2 mm greater in athletes with unspecified training (p < 0.02). To our knowledge, this is the largest compilation of studies documenting that elite athletes have larger LA dimensions compared with controls when evaluated by either LA diameter or LA volume corrected for body surface area. The largest average LA diameters were reported in endurance athletes. Physicians evaluating athletes should be aware that the LA is increased in both strength- and endurance-trained elite athletes. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Enlarged Dural Sac in Idiopathic Bronchiectasis Implicates Heritable Connective Tissue Gene Variants
Birchard, Katherine R.; Lowe, Jared R.; Patrone, Michael V.
2016-01-01
Rationale: Patients with idiopathic bronchiectasis are predominantly female and have an asthenic body morphotype and frequent nontuberculous mycobacterial respiratory infections. They also demonstrate phenotypic features (scoliosis, pectus deformity, mitral valve prolapse) that are commonly seen in individuals with heritable connective tissue disorders. Objectives: To determine whether lumbar dural sac size is increased in patients with idiopathic bronchiectasis as compared with control subjects, and to assess whether dural sac size is correlated with phenotypic characteristics seen in individuals with heritable connective tissue disorders. Methods: Two readers blinded to diagnosis measured anterior–posterior and transverse dural sac diameter using L1–L5 magnetic resonance images of 71 patients with idiopathic bronchiectasis, 72 control subjects without lung disease, 29 patients with cystic fibrosis, and 24 patients with Marfan syndrome. We compared groups by pairwise analysis of means, using Tukey’s method to adjust for multiple comparisons. Dural sac diameter association with phenotypic and clinical features was also tested. Measurements and Main Results: The L1–L5 (average) anterior–posterior dural sac diameter of the idiopathic bronchiectasis group was larger than those of the control group (P < 0.001) and the cystic fibrosis group (P = 0.002). There was a strong correlation between increased dural sac size and the presence of pulmonary nontuberculous mycobacterial infection (P = 0.007) and long fingers (P = 0.003). A trend toward larger dural sac diameter was seen in those with scoliosis (P = 0.130) and those with a family history of idiopathic bronchiectasis (P = 0.149). Conclusions: Individuals with idiopathic bronchiectasis have an enlarged dural sac diameter, which is associated with pulmonary nontuberculous mycobacterial infection, long fingers, and family history of idiopathic bronchiectasis. These findings support our hypothesis that “idiopathic” bronchiectasis development reflects complex genetic variation in heritable connective tissue and associated transforming growth factor-β–related pathway genes. PMID:27409985
Structural phase transitions in SrTiO 3 nanoparticles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Han; Liu, Sizhan; Scofield, Megan E.
2017-07-31
Pressure dependent structural measurements on monodispersed nanoscale SrTiO3 samples with average diameters of 10 to ~80 nm were conducted to enhance the understanding of the structural phase diagram of nanoscale SrTiO3. A robust pressure independent polar structure was found in the 10 nm sample for pressures up to 13 GPa, while a size dependent cubic to tetragonal transition occurs (at P = Pc) for larger particle sizes. The results suggest that the growth of ~10 nm STO particles on substrates with significant lattice mismatch may maintain a polar state for a large range of strain values, possibly enabling device use.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Landa, Romina A.; Soledad Antonel, Paula; Ruiz, Mariano M.
2013-12-07
Nickel (Ni) based nanoparticles and nanochains were incorporated as fillers in polydimethylsiloxane (PDMS) elastomers and then these mixtures were thermally cured in the presence of a uniform magnetic field. In this way, macroscopically structured-anisotropic PDMS-Ni based magnetorheological composites were obtained with the formation of pseudo-chains-like structures (referred as needles) oriented in the direction of the applied magnetic field when curing. Nanoparticles were synthesized at room temperature, under air ambient atmosphere (open air, atmospheric pressure) and then calcined at 400 °C (in air atmosphere also). The size distribution was obtained by fitting Small Angle X-ray Scattering (SAXS) experiments with a polydisperse hardmore » spheres model and a Schulz-Zimm distribution, obtaining a size distribution centered at (10.0 ± 0.6) nm with polydispersivity given by σ = (8.0 ± 0.2) nm. The SAXS, X-ray powder diffraction, and Transmission Electron Microscope (TEM) experiments are consistent with single crystal nanoparticles of spherical shape (average particle diameter obtained by TEM: (12 ± 1) nm). Nickel-based nanochains (average diameter: 360 nm; average length: 3 μm, obtained by Scanning Electron Microscopy; aspect ratio = length/diameter ∼ 10) were obtained at 85 °C and ambient atmosphere (open air, atmospheric pressure). The magnetic properties of Ni-based nanoparticles and nanochains at room temperature are compared and discussed in terms of surface and size effects. Both Ni-based nanoparticles and nanochains were used as fillers for obtaining the PDMS structured magnetorheological composites, observing the presence of oriented needles. Magnetization curves, ferromagnetic resonance (FMR) spectra, and strain-stress curves of low filler's loading composites (2% w/w of fillers) were determined as functions of the relative orientation with respect to the needles. The results indicate that even at low loadings it is possible to obtain magnetorheological composites with anisotropic properties, with larger anisotropy when using nanochains. For instance, the magnetic remanence, the FMR field, and the elastic response to compression are higher when measured parallel to the needles (about 30% with nanochains as fillers). Analogously, the elastic response is also anisotropic, with larger anisotropy when using nanochains as fillers. Therefore, all experiments performed confirm the high potential of nickel nanochains to induce anisotropic effects in magnetorheological materials.« less
McAuley, T R; Fisher, R; Zhou, X; Jaques, P A; Ferro, A R
2010-08-01
During winter 2006, indoor and outdoor ultrafine particle (UFP) size distribution measurements for particles with diameters from 5.6 to 165 nm were taken at five homes in a neighborhood directly adjacent to the Peace Bridge Complex (PBC), a major international border crossing connecting Buffalo, New York to Fort Erie, Ontario. Monitoring with 1-s time resolution was conducted for several hours at each home. Participants were instructed to keep all external windows and doors closed and to refrain from cooking, smoking, or other activity that may result in elevating the indoor UFP number concentration. Although the construction and age for the homes were similar, indoor-to-outdoor comparisons indicate that particle infiltration rates varied substantially. Overall, particle concentrations indoors were lower and less variable than particle concentrations outdoors, with average indoor-outdoor ratios ranging from 0.1 to 0.5 (mean 0.34) for particles between 5.6 and 165 nm in diameter. With no indoor sources, the average indoor-outdoor ratios were lowest (0.2) for 20-nm particles, higher (0.3) for particles <10 nm, and highest (0.5) for particles 70-165 nm. This study provides insight into the penetration of UFP into homes and the resulting change in particle size distributions as particles move indoors near a major diesel traffic source. Although people spend most of their time in their homes, exposure estimates for epidemiological studies are generally determined using ambient concentrations. The findings of this study will contribute to improved size-resolved UFP exposure estimates for near roadway exposure assessments and epidemiological studies.
Kimbal, Kyle C; Pahler, Leon; Larson, Rodney; VanDerslice, Jim
2012-01-01
Currently, there is no Mine Safety and Health Administration (MSHA)-approved sampling method that provides real-time results for ambient concentrations of diesel particulates. This study investigated whether a commercially available aerosol spectrometer, the Grimm Portable Aerosol Spectrometer Model 1.109, could be used during underground mine operations to provide accurate real-time diesel particulate data relative to MSHA-approved cassette-based sampling methods. A subset was to estimate size-specific diesel particle densities to potentially improve the diesel particulate concentration estimates using the aerosol monitor. Concurrent sampling was conducted during underground metal mine operations using six duplicate diesel particulate cassettes, according to the MSHA-approved method, and two identical Grimm Model 1.109 instruments. Linear regression was used to develop adjustment factors relating the Grimm results to the average of the cassette results. Statistical models using the Grimm data produced predicted diesel particulate concentrations that highly correlated with the time-weighted average cassette results (R(2) = 0.86, 0.88). Size-specific diesel particulate densities were not constant over the range of particle diameters observed. The variance of the calculated diesel particulate densities by particle diameter size supports the current understanding that diesel emissions are a mixture of particulate aerosols and a complex host of gases and vapors not limited to elemental and organic carbon. Finally, diesel particulate concentrations measured by the Grimm Model 1.109 can be adjusted to provide sufficiently accurate real-time air monitoring data for an underground mining environment.
Hsu, Ya-Chu; Hung, Yu-Chen; Wang, Chiu-Yen
2017-09-15
High uniformity Au-catalyzed indium selenide (In 2 Se 3) nanowires are grown with the rapid thermal annealing (RTA) treatment via the vapor-liquid-solid (VLS) mechanism. The diameters of Au-catalyzed In 2 Se 3 nanowires could be controlled with varied thicknesses of Au films, and the uniformity of nanowires is improved via a fast pre-annealing rate, 100 °C/s. Comparing with the slower heating rate, 0.1 °C/s, the average diameters and distributions (standard deviation, SD) of In 2 Se 3 nanowires with and without the RTA process are 97.14 ± 22.95 nm (23.63%) and 119.06 ± 48.75 nm (40.95%), respectively. The in situ annealing TEM is used to study the effect of heating rate on the formation of Au nanoparticles from the as-deposited Au film. The results demonstrate that the average diameters and distributions of Au nanoparticles with and without the RTA process are 19.84 ± 5.96 nm (30.00%) and about 22.06 ± 9.00 nm (40.80%), respectively. It proves that the diameter size, distribution, and uniformity of Au-catalyzed In 2 Se 3 nanowires are reduced and improved via the RTA pre-treated. The systemic study could help to control the size distribution of other nanomaterials through tuning the annealing rate, temperatures of precursor, and growth substrate to control the size distribution of other nanomaterials. Graphical Abstract Rapid thermal annealing (RTA) process proved that it can uniform the size distribution of Au nanoparticles, and then it can be used to grow the high uniformity Au-catalyzed In 2 Se 3 nanowires via the vapor-liquid-solid (VLS) mechanism. Comparing with the general growth condition, the heating rate is slow, 0.1 °C/s, and the growth temperature is a relatively high growth temperature, > 650 °C. RTA pre-treated growth substrate can form smaller and uniform Au nanoparticles to react with the In 2 Se 3 vapor and produce the high uniformity In 2 Se 3 nanowires. The in situ annealing TEM is used to realize the effect of heating rate on Au nanoparticle formation from the as-deposited Au film. The byproduct of self-catalyzed In 2 Se 3 nanoplates can be inhibited by lowering the precursors and growth temperatures.
Shiqing, Liu; Wenxu, Qi; Jin, Zhang; Youjing, Dong
2018-04-01
The aims of this study were to measure diameters of the cricoid ring and left main bronchus in Asian adult patients and to assess the accuracy of double lumen tube size selected according to cricoid and left main bronchus diameter, respectively. Retrospective observational study. Academic, tertiary care hospital. Preoperative CT scans from 87 men and 94 women who had undergone general anesthesia for lung operations. No intervention. The diameters of the cricoid ring and left main bronchus were measured from thoracic computed tomography images after correction of slant. The "best-fit" size of double lumen tube was determined by comparing diameter of the left main bronchus and cricoid ring with the diameter of the double lumen tube. Diameters of the cricoid ring and left main bronchus were both significantly greater in men compared with women (p < 0.0001). Shapes of cricoid rings were different between genders (p < 0.0001), while shapes of the left main bronchus were not significant different (p = 0.343). With reference to the "best fit" size, the rate of agreement of cricoid ring size, left main bronchus size, and height size for men were 100%, 100%, and 94.3%. For women, the rate of agreement of cricoid ring size, left main bronchus size, and height size were 94.7%, 63.8%, and 51.1%. The "best fit" size of a double lumen tube should be decided by a combination of diameters of the cricoid ring and the left main bronchus. Copyright © 2017 Elsevier Inc. All rights reserved.
An Experimental Investigation of Unsteady Thrust Augmentation Using a Speaker-Driven Jet
NASA Technical Reports Server (NTRS)
Paxson, Daniel E.; Wernet, Mark P.; John, Wentworth T.
2004-01-01
An experimental investigation is described in which a simple speaker-driven jet was used as a pulsed thrust source (driver) for an ejector configuration. The objectives of the investigation were twofold: first, to add to the experimental body of evidence showing that an unsteady thrust source, combined with a properly sized ejector generally yields higher thrust augmentation values than a similarly sized, steady driver of equivalent thrust. Second, to identify characteristics of the unsteady driver that may be useful for sizing ejectors, and predicting what thrust augmentation values may be achieved. The speaker-driven jet provided a convenient source for the investigation because it is entirely unsteady (having no mean component) and because relevant parameters such as frequency, time-averaged thrust, and diameter are easily variable. The experimental setup will be described, as will the various measurements made. These include both thrust and Digital Particle Imaging Velocimetry of the driver. It will be shown that thrust augmentation values as high as 1.8 were obtained, that the diameter of the best ejector scaled with the dimensions of the emitted vortex, and that the so-called Formation Number serves as a useful dimensionless number by which to characterize the jet and predict performance.
NASA Astrophysics Data System (ADS)
Winter, H.; Christopher-Allison, E.; Brown, A. L.; Goforth, A. M.
2018-04-01
Herein, we report an aerobic synthesis method to produce bismuth nanoparticles (Bi NPs) with average diameters in the range 40-80 nm using commercially available bismuth triiodide (BiI3) as the starting material; the method uses only readily available chemicals and conventional laboratory equipment. Furthermore, size data from replicates of the synthesis under standard reaction conditions indicate that this method is highly reproducible in achieving Bi NP populations with low standard deviations in the mean diameters. We also investigated the mechanism of the reaction, which we determined results from the reduction of a soluble alkylammonium iodobismuthate precursor species formed in situ. Under appropriate concentration conditions of iodobismuthate anion, we demonstrate that burst nucleation of Bi NPs results from reduction of Bi3+ by the coordinated, redox non-innocent iodide ligands when a threshold temperature is exceeded. Finally, we demonstrate phase transfer and silica coating of the Bi NPs, which results in stable aqueous colloids with retention of size, morphology, and colloidal stability. The resultant, high atomic number, hydrophilic Bi NPs prepared using this synthesis method have potential for application in emerging x-ray contrast and x-ray therapeutic applications.
Delivery of propellant soluble drug from a metered dose inhaler.
Ashworth, H L; Wilson, C G; Sims, E E; Wotton, P K; Hardy, J G
1991-01-01
The deposition of particulate suspensions delivered from a metered dose inhaler has been investigated extensively. The distribution of propellant, delivered from a metered dose inhaler, was studied by radiolabelling it with technetium-99m hexamethylpropyleneamine oxime. Andersen sampler measurements indicated that half of the dose was associated with particles in the size range 0.5-5 microns diameter. The preparation was administered to healthy subjects by inhalation and deposition was monitored with a gamma camera. Each lung image was divided into an inner, mid, and peripheral zone. The effects on deposition of varying the size of the delivery orifice (0.46, 0.61, and 0.76 mm internal diameters) and the effect of attaching a spacer were assessed. Lung deposition was independent of the orifice size within the actuator. Without the spacer the average dose deposited in the lungs was 39%, with 15% penetrating into the peripheral part of the lungs. Attachment of the spacer to the mouth-piece increased the mean lung deposition to 57% and reduced oropharyngeal deposition. The study has shown that propellant soluble drugs can be delivered efficiently to the lungs from a metered dose inhaler. Images PMID:2038731
Bridson, R H; Santos, R C D; Al-Duri, B; McAllister, S M; Robertson, J; Alpar, H O
2006-06-01
Numerous strategies are currently available for preparing liposomes, although no single method is ideal in every respect. Two methods for producing liposomes using compressed carbon dioxide in either its liquid or supercritical state were therefore investigated as possible alternatives to the conventional techniques currently used. The first technique used modified compressed carbon dioxide as a solvent system. The way in which changes in pressure, temperature, apparatus geometry and solvent flow rate affected the size distributions of the formulations was examined. In general, liposomes in the nano-size range with an average diameter of 200 nm could be produced, although some micron-sized vesicles were also present. Liposomes were characterized according to their hydrophobic drug-loading capacity and encapsulated aqueous volumes. The latter were found to be higher than in conventional techniques such as high-pressure homogenization. The second method used compressed carbon dioxide as an anti-solvent to promote uniform precipitation of phospholipids from concentrated ethanolic solutions. Finely divided solvent-free phospholipid powders of saturated lipids could be prepared that were subsequently hydrated to produce liposomes with mean volume diameters of around 5 microm.
Arrays of size and distance controlled platinum nanoparticles fabricated by a colloidal method
NASA Astrophysics Data System (ADS)
Manzke, Achim; Vogel, Nicolas; Weiss, Clemens K.; Ziener, Ulrich; Plettl, Alfred; Landfester, Katharina; Ziemann, Paul
2011-06-01
Based on emulsion polymerization in the presence of a Pt complex, polystyrene (PS) particles were prepared exhibiting a well defined average diameter with narrow size-distribution. Furthermore, the colloids contain a controlled concentration of the Pt precursor complex. Optimized coating of Si substrates with such colloids leads to extended areas of hexagonally ordered close-packed PS particles. Subsequent application of plasma etching and annealing steps allows complete removal of the PS carriers and in parallel nucleation and growth of Pt nanoparticles (NPs) which are located at the original center of the PS colloids. In this way, hexagonally arranged spherical Pt NPs are obtained with controlled size and interparticle distances demonstrating variability and precision with so far unknown parameter scalability. This control is demonstrated by the fabrication of Pt NP arrays at a fixed particle distance of 185 nm while systematically varying the diameters between 8 and 15 nm. Further progress could be achieved by seeded emulsion polymerization. Here, Pt loaded PS colloids of 130 nm were used as seeds for a subsequent additional emulsion polymerization, systematically enlarging the diameter of the PS particles. Applying the plasma and annealing steps as above, in this way hexagonally ordered arrays of 9 nm Pt NPs could be obtained at distances up to 260 nm. To demonstrate their stability, such Pt particles were used as etching masks during reactive ion etching thereby transferring their hexagonal pattern into the Si substrate resulting in corresponding arrays of nanopillars.Based on emulsion polymerization in the presence of a Pt complex, polystyrene (PS) particles were prepared exhibiting a well defined average diameter with narrow size-distribution. Furthermore, the colloids contain a controlled concentration of the Pt precursor complex. Optimized coating of Si substrates with such colloids leads to extended areas of hexagonally ordered close-packed PS particles. Subsequent application of plasma etching and annealing steps allows complete removal of the PS carriers and in parallel nucleation and growth of Pt nanoparticles (NPs) which are located at the original center of the PS colloids. In this way, hexagonally arranged spherical Pt NPs are obtained with controlled size and interparticle distances demonstrating variability and precision with so far unknown parameter scalability. This control is demonstrated by the fabrication of Pt NP arrays at a fixed particle distance of 185 nm while systematically varying the diameters between 8 and 15 nm. Further progress could be achieved by seeded emulsion polymerization. Here, Pt loaded PS colloids of 130 nm were used as seeds for a subsequent additional emulsion polymerization, systematically enlarging the diameter of the PS particles. Applying the plasma and annealing steps as above, in this way hexagonally ordered arrays of 9 nm Pt NPs could be obtained at distances up to 260 nm. To demonstrate their stability, such Pt particles were used as etching masks during reactive ion etching thereby transferring their hexagonal pattern into the Si substrate resulting in corresponding arrays of nanopillars. Electronic supplementary information (ESI) available: Detailed description of the experimental part (S1-S4) platinum concentration inside the polymer particles synthesized by a seeded polymerization from the same seed particles measured by ICP-OES (Fig. S1 and S5); SEM image of Pt complex containing PS particles after oxygen plasma treatment (Fig. S2 and S6); effect of hydrofluoric acid treatment on silicon oxide elevation under Pt NPs (Fig. S3 and S6); SEM images demonstrating the variability of Pt NP distance while keeping the diameter constant (Fig. S4 and S8); results of experimental determination of Pt content by ICP-OES (Tables S1 and S9); diameter of the particles at different fabrication states (Tables S2 and S10). See DOI: 10.1039/c1nr10169b
Photomicrographic Investigation of Spontaneous Freezing Temperatures of Supercooled Water Droplets
NASA Technical Reports Server (NTRS)
Dorsch, R. G.; Hacker, P. T.
1950-01-01
A photomicrographic technique for investigating eupercooled. water droplets has been devised and. used. to determine the spontaneous freezing temperatures of eupercooled. water droplets of the size ordinarily found. in the atmosphere. The freezing temperatures of 4527 droplets ranging from 8.75 to 1000 microns in diameter supported on a platinum surface and 571 droplets supported on copper were obtained. The average spontaneous freezing temperature decreased with decrease in the size of the droplets. The effect of size on the spontaneous freezing temperature was particularly marked below 60 microns. Frequency-distribution curves of the spontaneous freezing temperatures observed for droplets of a given size were obtained. Although no droplet froze at a temperature above 20 0 F, all droplets melted at 32 F. Results obtained with a copper support did not differ essentially from those obtained with a platinum surface.
D'Agostino, H B; Park, Y; Moyers, J P; vanSonnenberg, E; Sanchez, R B; Goodacre, B W; Kim, Y H; Vieira, M V
1992-08-01
The effects of stopcocks on percutaneous fluid drainage were tested in a laboratory model by using a standard stopcock (6-French inner diameter) and a prototype stopcock (9-French inner diameter) connected to 8-, 10-, 12-, 14-, and 16-French catheters. Catheters were immersed in water alone or in viscous fluid with particulate matter, and the system was connected to low wall suction or gravity drainage. The average volume of fluid aspirated in a given period with and without a stopcock was compared for each catheter. The standard stopcock decreased drainage efficiency for these catheters by 13-42%. This decreased drainage efficiency was worse with the larger catheters. Particulate fluid blocked the stopcock connection for all catheters. With the prototype stopcock, drainage of water alone was reduced by 0-9% for the catheters of different sizes. Particulate fluid did not obstruct the prototype stopcock with any size catheter. With gravity drainage, the volume of water aspirated was reduced by 12-42% with the standard stopcock and by 3-6% with the prototype stopcock. These data suggest that stopcock connections greatly influence the efficiency of the percutaneous drainage systems. Stopcocks with larger inner diameters may improve drainage over that achievable with the stopcocks that are currently available.
Peckys, Diana B; de Jonge, Niels
2014-02-01
The size of gold nanoparticles (AuNPs) can influence various aspects of their cellular uptake. Light microscopy is not capable of resolving most AuNPs, while electron microscopy (EM) is not practically capable of acquiring the necessary statistical data from many cells and the results may suffer from various artifacts. Here, we demonstrate the use of a fast EM method for obtaining high-resolution data from a much larger population of cells than is usually feasible with conventional EM. A549 (human lung carcinoma) cells were subjected to uptake protocols with 10, 15, or 30 nm diameter AuNPs with adsorbed serum proteins. After 20 min, 24 h, or 45 h, the cells were fixed and imaged in whole in a thin layer of liquid water with environmental scanning electron microscopy equipped with a scanning transmission electron microscopy detector. The fast preparation and imaging of 145 whole cells in liquid allowed collection of nanoscale data within an exceptionally small amount of time of ~80 h. Analysis of 1,041 AuNP-filled vesicles showed that the long-term AuNP storing lysosomes increased their average size by 80 nm when AuNPs with 30 nm diameter were uptaken, compared to lysosomes of cells incubated with AuNPs of 10 and 15 nm diameter.
Pratchett, Morgan S; Cowan, Zara-Louise; Nadler, Lauren E; Caballes, Ciemon F; Hoey, Andrew S; Messmer, Vanessa; Fletcher, Cameron S; Westcott, David A; Ling, Scott D
2017-01-01
The movement capacity of the crown-of-thorns starfishes (Acanthaster spp.) is a primary determinant of both their distribution and impact on coral assemblages. We quantified individual movement rates for the Pacific crown-of-thorns starfish (Acanthaster solaris) ranging in size from 75-480 mm total diameter, across three different substrates (sand, flat consolidated pavement, and coral rubble) on the northern Great Barrier Reef. The mean (±SE) rate of movement for smaller (<150 mm total diameter) A. solaris was 23.99 ± 1.02 cm/ min and 33.41 ± 1.49 cm/ min for individuals >350 mm total diameter. Mean (±SE) rates of movement varied with substrate type, being much higher on sand (36.53 ± 1.31 cm/ min) compared to consolidated pavement (28.04 ± 1.15 cm/ min) and slowest across coral rubble (17.25 ± 0.63 cm/ min). If average rates of movement measured here can be sustained, in combination with strong directionality, displacement distances of adult A. solaris could range from 250-520 m/ day, depending on the prevailing substrate. Sustained movement of A. solaris is, however, likely to be highly constrained by habitat heterogeneity, energetic constraints, resource availability, and diurnal patterns of activity, thereby limiting their capacity to move between reefs or habitats.
Krasa, Andrzej; Rogula-Kozłowska, Wioletta; Błaszczak, Barbara
2013-01-01
This work presents results from the long-term measurements of particle number carried out at an urban background station in Zabrze, Poland. Ambient particles with aerodynamic diameters of between 28 nm and 10 μm were investigated by means of a DEKATI thirteen-stage electrical low pressure impactor (ELPI). The particle number-size distribution was bimodal, whilst its density function had the local maxima in the aerodynamic diameter intervals 0.056–0.095 μm and 0.157–0.263 μm. The average particle number in winter was nearly twice as high as in summer. The greatest number concentrations in winter were those of the particles with diameters of between 0.617 and 2.41 μm, that is, the anthropogenic particles from fossil fuel combustion. Approximately 99% of the particles observed in Zabrze had aerodynamic diameters ≤1 μm—they may have originated from the combustion of biomass, liquid, and gaseous fuels in domestic stoves or in car engines. The daily variation of particle number was similar for both seasons—the highest values were observed in the morning (traffic rush hour) and in the afternoon/late evening (traffic and house heating emissions). An additional maximum (0.028–0.056 μm) observed in the early afternoon in summer was due to the intensive formation of new PM particles from gas precursors. PMID:24288492
Controlling diameter distribution of catalyst nanoparticles in arc discharge.
Li, Jian; Volotskova, Olga; Shashurin, Alexey; Keidar, Michael
2011-11-01
It is demonstrated that the diameter distribution of catalyst nanoparticles in arc discharge can be controlled by a magnetic field. The magnetic field affects the arc shape, shortens the diffusing time of the catalyst nanoparticles through the nucleation zone, and consequentially reduces the average diameters of nanoparticles. The average diameter is reduced from about 7.5 nm without magnetic field to about 5 nm is the case of a magnetic field. Decrease of the catalyst nanoparticle diameter with magnetic field correlates well with decrease in the single-wall carbon nanotube and their bundles diameters.
NASA Astrophysics Data System (ADS)
Moore, M. J.; Strohm, E. M.; Kolios, M. C.
2016-12-01
The nucleus-to-cytoplasmic (N:C) ratio of a cell is often used when assessing histology for the presence of malignant disease. In this proof of concept study, we present a new, non-optical method for determination of the N:C ratio using ultra-high Frequency ultrasound (US) and photoacoustics (PA). When using transducers in the 100 MHz-500 MHz range, backscattered US pulses and emitted PA waves are encoded with information pertaining to the dimension and morphology of micron-sized objects. If biological cells are interrogated, the diameter of the scattering or absorbing structure can be assessed by fitting the power spectra of the measured US or PA signals to theoretical models for US backscatter and PA emission from a fluid sphere. In this study, the cell and nucleus diameters of 9 MCF-7 breast cancer cells were determined using a new simplified model that calculates the theoretical values of the location of the power spectra minima for both US and PA signals. These diameters were then used to calculate the N:C ratio of the measured cells. The average cell diameter determined by US pulses from a transducer with a central frequency of 375 MHz was found to be 15.5 μ m± 1.8 μ m. The PA waves emitted by the cell nuclei were used to determine an average nuclear diameter of 12.0 μ m± 1.3 μ m. The N:C ratio for these cells was calculated to be 1.9± 1.0, which agrees well with previously reported N:C values for this cell type.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Golokhvast, Kirill S.; Chernyshev, Valery V.; Chaika, Vladimir V.
2015-10-15
The study aims at investigating the characteristics (size distribution, active surface and metal content) of particles emitted by cars as a function of mileage using a novel methodology for characterizing particulate emissions captured by Exhaust Gas Suspension (EGS). EGS was obtained by passing the exhaust gases through a container of deionized water. EGS analysis was performed using laser granulometry, electron scanning microscopy, and high resolution mass spectrometry. Implications of the differences in key features of the emitted particles on population exposure were investigated using numerical simulation for estimating size-segregated PM deposition across human respiratory tract (HRT). It was found thatmore » vehicle mileage, age and the respective emissions class have almost no effect on the size distribution of the exhaust gas particulate released into the environment; about half of the examined vehicles with low mileage were found to release particles of aerodynamic diameter above 10 μm. The exhaust gas particulate detected in the EGS of all cars can be classified into three major size classes: (1) 0.1–5 µm – soot and ash particles, metals (Au, Pt, Pd, Ir); (2) 10–30 µm – metal (Cr, Fe, Cu, Zr, Ni) and ash particles; (3) 400–1,000 µm – metal (Fe, Cr, Pb) and ash particles. Newer vehicles with low mileage are substantial sources of soot and metal particles with median diameter of 200 nm with a higher surface area (up to 89,871.16 cm{sup 2}/cm{sup 3}). These tend to deposit in the lower part of the human respiratory tract. - Highlights: • Car mileage has virtually no effect on the size of the solid particles released. • Newer diesel vehicles emit particles of lower aerodynamic diameter. • Particle active surface emitted by newer vehicles is on average 3 times higher. • Real-life emissions were translated into actual internal PM exposure.« less
Injectable and porous PLGA microspheres that form highly porous scaffolds at body temperature
Qutachi, Omar; Vetsch, Jolanda R.; Gill, Daniel; Cox, Helen; Scurr, David J.; Hofmann, Sandra; Müller, Ralph; Quirk, Robin A.; Shakesheff, Kevin M.; Rahman, Cheryl V.
2014-01-01
Injectable scaffolds are of interest in the field of regenerative medicine because of their minimally invasive mode of delivery. For tissue repair applications, it is essential that such scaffolds have the mechanical properties, porosity and pore diameter to support the formation of new tissue. In the current study, porous poly(dl-lactic acid-co-glycolic acid) (PLGA) microspheres were fabricated with an average size of 84 ± 24 μm for use as injectable cell carriers. Treatment with ethanolic sodium hydroxide for 2 min was observed to increase surface porosity without causing the microsphere structure to disintegrate. This surface treatment also enabled the microspheres to fuse together at 37 °C to form scaffold structures. The average compressive strength of the scaffolds after 24 h at 37 °C was 0.9 ± 0.1 MPa, and the average Young’s modulus was 9.4 ± 1.2 MPa. Scaffold porosity levels were 81.6% on average, with a mean pore diameter of 54 ± 38 μm. This study demonstrates a method for fabricating porous PLGA microspheres that form solid porous scaffolds at body temperature, creating an injectable system capable of supporting NIH-3T3 cell attachment and proliferation in vitro. PMID:25152354
Tappeiner, J. C.; Zasada, J.; Maxwell, B.
1996-01-01
In order to determine the effects of stump height, year of cutting, parent-tree size, logging damage, and deer browsing on bigleaf maple (Acer macrophyllum) sprout clump development, maple trees were cut to two stump heights at three different times. Stump height had the greatest impact on sprout clump size. Two years after clearcutting, the sprout clump volume for short stumps was significantly less than that for tall stumps. The sprout clump volume, area, and number of sprouts were significantly less for trees cut 1 and 2 yr before harvest than for trees cut at harvest. Sprout clump size was positively correlated with parent tree stem diameter and stump volume, and negatively correlated with the percentage of bark removed during logging. Browsing had no significant impact on average clump size. Uncut trees produced sprout clumps at their base and epicormic branches along the length of their stems; thus their crown volume averaged four to five times that of cut trees. Cutting maple in clearcuts to low stumps may reduce maple competition with Douglas-fir regeneration and still maintain maple in the next stand.
Iyer, Vidyashankara; Cayatte, Corinne; Guzman, Bernardo; Schneider-Ohrum, Kirsten; Matuszak, Ryan; Snell, Angie; Rajani, Gaurav Manohar; McCarthy, Michael P; Muralidhara, Bilikallahalli
2015-01-01
Oil-in-water emulsions have gained consideration as vaccine adjuvants in recent years due to their ability to elicit a differentiated immunogenic response compared to traditional aluminum salt adjuvants. Squalene, a cholesterol precursor, is a natural product with immunostimulatory properties, making it an ideal candidate for such oil-in-water emulsions. Particle size is a key parameter of these emulsions and its relationship to stability and adjuvanticity has not been extensively studied. This study evaluates the effect of particle size on the stability and immunogenicity of squalene emulsions. We investigated the effect of formulation parameters such as surfactant concentration on particle size, resulting in particles with average diameter of 80 nm, 100 nm, 150 nm, 200 nm, or 250 nm. Emulsions were exposed to shear and temperature stresses, and stability parameters such as pH, osmolarity, size, and in-depth visual appearance were monitored over time. In addition, adjuvanticity of different particle size was assessed in a mouse model using Respiratory Syncytial Virus Fusion protein (RSV-F) as a model antigen. Temperature dependent phase separation appeared to be the most common route of degradation occurring in the higher particle sizes emulsions. The emulsions below 150 nm size maintained stability at either 5°C or 25°C, and the 80 nm diameter ones showed no measurable changes in size even after one month at 40°C. In vivo studies using the emulsions as an adjuvant with RSV F antigen revealed that superior immunogenicity could be achieved with the 80 nm particle size emulsion. PMID:26090563
Annual replenishment of bed material by sediment transport in the Wind River near Riverton, Wyoming
Smalley, M.L.; Emmett, W.W.; Wacker, A.M.
1994-01-01
The U.S. Geological Survey, in cooperation with the Wyoming Department of Transportation, conducted a study during 1985-87 to determine the annual replenishment of sand and gravel along a point bar in the Wind River near Riverton, Wyoming. Hydraulic- geometry relations determined from streamflow measurements; streamflow characteristics determined from 45 years of record at the study site; and analyses of suspended-sediment, bedload, and bed- material samples were used to describe river transport characteristics and to estimate the annual replenishment of sand and gravel. The Wind River is a perennial, snowmelt-fed stream. Average daily discharge at the study site is about 734 cubic feet per second, and bankfull discharge (recurrence interval about 1.5 years) is about 5,000 cubic feet per second. At bankfull discharge, the river is about 136 feet wide and has an average depth of about 5.5 feet and average velocity of about 6.7 feet per second. Streams slope is about 0.0010 foot per foot. Bed material sampled on the point bar before the 1986 high flows ranged from sand to cobbles, with a median diameter of about 22 millimeters. Data for sediment samples collected during water year 1986 were used to develop regression equations between suspended-sediment load and water discharge and between bedload and water discharge. Average annual suspended-sediment load was computed to be about 561,000 tons per year using the regression equation in combination with flow-duration data. The regression equation for estimating bedload was not used; instead, average annual bedload was computed as 1.5 percent of average annual suspended load about 8,410 tons per year. This amount of bedload material is estimated to be in temporary storage along a reach containing seven riffles--a length of approximately 1 river mile. On the basis of bedload material sampled during the 1986 high flows, about 75 percent (by weight) is sand (2 millimeters in diameter or finer); median particle size is about 0.5 milli- meter. About 20 percent (by weight) is medium gravel to small cobbles--12.7 millimeters (0.5 inch) or coarser. The bedload moves slowly (about 0.03 percent of the water speed) and briefly (about 10 percent of the time). The average travel distance of a median-sized particle is about 1 river mile per year. The study results indicate that the average replenishment rate of bedload material coarser than 12.7 millimeters is about 1,500 to 2,000 tons (less than 1,500 cubic yards) per year. Finer material (0.075 to 6.4 millimeters in diameter) is replen- ishment at about 4,500 to 5,000 cubic yards per year. The total volume of potentially usable material would average about 6,000 cubic yards per year.
Growth of lodgepole pine stands and its relation to mountain pine beetle susceptibility
S.A. Mata; J.M. Schmid; W.K. Olsen
2003-01-01
Periodic diameter and basal area growth were determined for partially cut stands of lodgepole pine at five locations over approximately 10 year periods. After cutting, average diameters in the partially cut plots generally increased by 0.8 inches or more, while average diameter in the uncut controls increased by 0.6 inches or less. Diameter growth in the partially cut...
Size and shape dependent deprotonation potential and proton affinity of nanodiamond
NASA Astrophysics Data System (ADS)
Barnard, Amanda S.; Per, Manolo C.
2014-11-01
Many important reactions in biology and medicine involve proton abstraction and transfer, and it is integral to applications such as drug delivery. Unlike electrons, which are quantum mechanically delocalized, protons are instantaneously localized on specific residues in these reactions, which can be a distinct advantage. However, the introduction of nanoparticles, such as non-toxic nanodiamonds, to this field complicates matters, as the number of possible sites increases as the inverse radius of the particle. In this paper we present \\gt {{10}4} simulations that map the size- and shape-dependence of the deprotonation potential and proton affinity of nanodiamonds in the range 1.8-2.7 nm in average diameter. We find that while the average deprotonation potential and proton affinities decrease with size, the site-specific values are inhomogeneous over the surface of the particles, exhibiting strong shape-dependence. The proton affinity is strongly facet-dependent, whereas the deprotonation potential is edge/corner-dependent, which creates a type of spatial hysteresis in the transfer of protons to and from the nanodiamond, and provides new opportunities for selective functionalization.
Farjadian, Fatemeh; Moradi, Sahar; Hosseini, Majid
2017-03-01
Magnetic nanoparticles have found application as MRI contrasting agents. Herein, chitosan thin films containing super-paramagnetic iron oxide nanoparticles (SPIONs) are evaluated in magnetic resonance imaging (MRI). To determine their contrasting capability, super-paramagnetic nanoparticles coated with citrate (SPIONs-cit) were synthesized. Then, chitosan thin films with different concentrations of SPIONs-cit were prepared and their MRI data (i.e., r 2 and r 2 *) was evaluated in an aqueous medium. The synthesized SPIONs-cit and chitosan/SPIONs-cit films were characterized by FTIR, EDX, XRD as well as VSM with the morphology evaluated by SEM and AFM. The nanoparticle sizes and distribution confirmed well-defined nanoparticles and thin films formation along with high contrasting capability in MRI. Images revealed well-dispersed uniform nanoparticles, averaging 10 nm in size. SPIONs-cit's hydrodynamic size averaged 23 nm in diameter. The crystallinity obeyed a chitosan and SPIONs pattern. The in vitro cellular assay of thin films with a novel route was performed within Hek293 cell lines showing that thin films can be biocompatible.
Reinstein, Dan Z; Lovisolo, Carlo F; Archer, Timothy J; Gobbe, Marine
2013-01-01
To compare vault height predictability of Implantable Collamer Lens (ICL; Staar Surgical) sizing using a sulcus diameter-based formula or the manufacturer-recommended white-to-white-based method. In 50 myopic eyes, ICL size was calculated using both a formula including sulcus diameter and the traditional formula based on white-to-white diameter. Sulcus diameter was measured using Artemis 2 very high-frequency (VHF) digital ultrasound (ArcScan Inc). Implantation was based on the sulcus diameter derived size. Actual postoperative vault height achieved was measured by VHF digital ultrasound scanning. Circle segment trigonometry was used to calculate the vault height that would have resulted had lens sizing been based on the white-to-white formula. The same lens size would have been used in 60% of eyes, a smaller lens would have been used in 34% of eyes and a larger lens in 6% of eyes had lens sizing been based on the white-to-white formula. Mean vault for eyes with lenses sized using the sulcus diameter formula was 0.37±0.16 mm (range: 0.08 to 0.92 mm), with 2% <0.09 mm, the recognized low-vault height for risk of cataract. Circle segment trigonometry predicted that the vault height would have been 0.24±0.28 mm (range: -0.31 to 0.92 mm), with 26% <0.09 mm had lens sizing been based on the white-to-white formula. Significantly better predictability of postoperative vault height was achieved by including sulcus diameter into the ICL sizing formula compared with using the traditional white-to-white-based formula. Copyright 2013, SLACK Incorporated.
Pal, Pallabi; Dadhich, Prabhash; Srivas, Pavan Kumar; Das, Bodhisatwa; Maulik, Dhrubajyoti; Dhara, Santanu
2017-08-22
Mimicking skin extracellular matrix hierarchy, the present work aims to develop a bilayer skin graft comprising a porous cotton-wool-like 3D layer with membranous structure of PCL-chitosan nanofibers. Emulsion electrospinning with differential stirring periods of PCL-chitosan emulsion results in development of a bilayer 3D structure with varied morphology. The electrospun membrane has fiber diameter ∼274 nm and pore size ∼1.16 μm while fluffy 3D layer has fiber diameter ∼1.62 μm and pore size ∼62 μm. The 3D layer was further coated with collagen I isolated from Cirrhinus cirrhosus fish scales to improve biofunctionality. Surface coating with collagen I resulted in bundling the fibers together, thereby increasing their average diameter to 2.80 μm and decreasing pore size to ∼45 μm. The architecture and composition of the scaffold promotes efficient cellular activity where interconnected porosity with ECM resembling collagen I coating assists cellular adhesion, infiltration, and proliferation from initial days of fibroblast seeding, while keratinocytes migrate on the surface only without infiltrating in the membranous nanofiber layer. Anatomy of the scaffold arising due to variation in pore size distribution at different layers thereby facilitates compartmentalization and prevents initial cellular transmigration. The scaffold also assists in extracellular matrix protein synthesis and keratinocyte stratification in vitro. Further, the scaffold effectively integrates and attaches with third-degree burn wound margins created in rat models and accelerates healing in comparison to standard Tegaderm dressing™. The bilayer scaffold is thus a promising, readily available, cost-effective, off-the-shelf matrix as a skin substitute.
Ryu, Se-Ah; Kim, Chang Sup; Kim, Hye-Jung; Baek, Dae Heoun; Oh, Deok-Kun
2003-01-01
D-Tagatose was continuously produced using thermostable L-arabinose isomerase immobilized in alginate with D-galactose solution in a packed-bed bioreactor. Bead size, L/D (length/diameter) of reactor, dilution rate, total loaded enzyme amount, and substrate concentration were found to be optimal at 0.8 mm, 520/7 mm, 0.375 h(-1), 5.65 units, and 300 g/L, respectively. Under these conditions, the bioreactor produced about 145 g/L tagatose with an average productivity of 54 g tagatose/L x h and an average conversion yield of 48% (w/w). Operational stability of the immobilized enzyme was demonstrated, with a tagatose production half-life of 24 days.
Liu, Xin; Rahaman, Mohamed N.; Fu, Qiang
2010-01-01
Scaffolds of 13-93 bioactive glass (composition 6Na2O, 8K2O, 8MgO, 22CaO, 2P2O5, 54SiO2; mol %), containing oriented pores with controllable diameter, were prepared by unidirectional freezing of camphene-based suspensions (10 vol% particles) on a cold substrate (−196°C or 3°C). By varying the annealing time (0–72 h) to coarsen the camphene phase, constructs with the same porosity (86 ± 1%) but with controllable pore diameters (15–160 μm) were obtained after sublimation of the camphene. The pore diameters had a self-similar distribution that could be fitted by a diffusion-controlled coalescence model. Sintering (1 h at 690°C) was accompanied by a decrease in the porosity and pore diameter, the magnitude of which depended on the pore size of the green constructs, giving scaffolds with a porosity of 20–60% and average pore diameter of 6–120 μm. The compressive stress vs. deformation response of the sintered scaffolds in the orientation direction was linear, followed by failure. The compressive strength and elastic modulus in the orientation direction varied from 180 MPa and 25 GPa, respectively, (porosity = 20%) to 16 MPa and 4 GPa, respectively, (porosity = 60%), which were 2–3 times larger than the values in the direction perpendicular to the orientation. The potential use of these 13-93 bioactive glass scaffolds for the repair of large defects in load-bearing bones, such as segmental defects in long bones, is discussed. PMID:20807594
Fast synthesis and consolidation of porous FeAl by pressureless Spark Plasma Sintering
NASA Astrophysics Data System (ADS)
Dudina, D. V.; Brester, A. E.; Anisimov, A. G.; Bokhonov, B. B.; Legan, M. A.; Novoselov, A. N.; Skovorodin, I. N.; Uvarov, N. F.
2017-07-01
We report one-step fast synthesis and consolidation of iron aluminide FeAl of high open porosity by pressureless reactive Spark Plasma Sintering (SPS). The starting material of the Fe-40at.%Al composition was a mixture of an iron powder with an average particle diameter of 4 μm and an aluminum powder with an average particle diameter of 6 μm. The rationale behind the choice of the SPS as a processing technique and fine and comparable sizes of the two reactants for the synthesis of high-open porosity FeAl was realization of fast full chemical conversion of Fe and Al into single-phase FeAl reducing the time available for the compact shrinkage. According to the XRD phase analysis, single-phase FeAl compacts formed after SPS at 800 and 900°C. These compacts had open porosities of 41 and 46%, respectively. The transverse rupture strength of the compacts sintered at 700-900°C was found to change little with the sintering temperature in the selected range.
Xiang, Ping; Li, Min; Zhang, Chao-ying; Chen, Deng-long; Zhou, Zhi-hua
2011-10-01
A tubular scaffold was fabricated by using electrospun polymer solution blends of pNSR32 (recombinant spider silk protein), PCL (polycaprolactone) and Gt (gelatin). The physicochemical properties and cytocompatibility of these scaffolds were investigated. Afterwards, the pNSR32/PCL/Gt tubular scaffold (inner diameter=3mm) showed high porosity of 86.2 ± 2.9%, pore size of 2423 ± 979nm and average fibre diameter of 166 ± 85nm. Water uptake and contact angle of the scaffolds reached 112.0 ± 4.4% and 45.7 ± 13.7°, respectively. SDRAECs (Sprague Dawley Rat Aortic Endothelial Cells) grew and proliferated well and phenotype could be maintained on the composite scaffolds after they had been cultured on the composite scaffolds for 7 days. Compared with pure PCL scaffolds a greater density of viable cells was seen on the composites, especially the pNSR32/PCL/Gt scaffolds. Copyright © 2011 Elsevier B.V. All rights reserved.
Stability and Decay Properties of Foam in Seawater.
1987-04-24
DECAY PROPERTIES OF FOAM IN SEAWATER FMRODUCTION Foam is formed by the entrainment of air in the form of small bubbles at and just beneath the...181 has examined how the size distributions of foam patches formed by wave action on a sandy beach vary with time. It was found that the mean diameter...typical foam patch was 25 seconds. Zheng et al [25] also measured the average lifetime of a foam layer formed at the surface by wave breaking on a
Chandler, John E; Lee, Cameron M; Babchanik, Alexander P; Melville, C David; Saunders, Michael D; Seibel, Eric J
2012-01-01
Purpose Direct visualization of pancreatic ductal tissue is critical for early diagnosis of pancreatic diseases and for guiding therapeutic interventions. A novel, ultrathin (5 Fr) scanning fiber endoscope (SFE) with tip-bending capability has been developed specifically to achieve high resolution imaging as a pancreatoscope during endoscopic retrograde cholangiopancreatography (ERCP). This device has potential to dramatically improve both diagnostic and therapeutic capabilities during ERCP by providing direct video feedback and tool guidance to clinicians. Methods Invasiveness of the new tip-bending SFE was evaluated by a performance comparison to ERCP guide wires, which are routinely inserted into the pancreatic duct during ERCP. An in vitro test model with four force sensors embedded in a synthetic pancreas was designed to detect and compare the insertion forces for 0.89 mm and 0.53 mm diameter guide wires as well as the 1.7 mm diameter SFE. Insertions were performed through the working channel of a therapeutic duodenoscope for the two types of guide wires and using a statistically similar direct insertion method for comparison to the SFE. Results Analysis of the forces detected by the sensors showed the smaller diameter 0.53 mm wire produced significantly less average and maximum forces during insertion than the larger diameter 0.89 mm wire. With the use of tip-bending and optical visualization, the 1.7 mm diameter SFE produced significantly less average force during insertion than the 0.89 mm wire at every sensor, despite its larger size. It was further shown that the use of tip-bending with the SFE significantly reduced the forces at all sensors, compared to insertions when tip-bending was not used. Conclusion Combining high quality video imaging with two-axis tip-bending allows a larger diameter guide wire-style device to be inserted into the pancreatic duct during ERCP with improved capacity to perform diagnostics and therapy. PMID:23166452
Suarez-Ahedo, Carlos; Gui, Chengcheng; Martin, Timothy J; Chandrasekaran, Sivashankar; Lodhia, Parth; Domb, Benjamin G
2017-03-31
To compare the acetabular component size relative to the patient's native femoral head size between conventional THA (CTHA) approach and robotic-arm assisted THA (RTHA) to infer which of these techniques preserved more acetabular bone. Patients were included if they had primary osteoarthritis (OA) and underwent total hip replacement between June 2008 and March 2014. Patients were excluded if they had missing or rotated postoperative anteroposterior radiographs. RTHA patients were matched to a control group of CTHA patients, in terms of preoperative native femoral head size, age, gender, body mass index (BMI) and approach. Acetabular cup size relative to femoral head size was used as a surrogate for amount of bone resected. We compared the groups according to 2 measures describing acetabular cup diameter (c) in relation to femoral head diameter (f): (i) c-f, the difference between cup diameter and femoral head diameter and (ii) (c-f)/f, the same difference as a fraction of femoral head diameter. 57 matched pairs were included in each group. There were no significant differences between groups for demographic measures, femoral head diameter, or acetabular cup diameter (p>0.05). However, measures (i) and (ii) did differ significantly between the groups, with lower values in the RTHA group (p<0.02). Using acetabular cup size relative to femoral head size as an approximate surrogate measure of acetabular bone resection may suggest greater preservation of bone stock using RTHA compared to CTHA. Further studies are needed to validate the relationship between acetabular cup size and bone loss in THA.
An Investigation into Solution Verification for CFD-DEM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fullmer, William D.; Musser, Jordan
This report presents the study of the convergence behavior of the computational fluid dynamicsdiscrete element method (CFD-DEM) method, specifically National Energy Technology Laboratory’s (NETL) open source MFiX code (MFiX-DEM) with a diffusion based particle-tocontinuum filtering scheme. In particular, this study focused on determining if the numerical method had a solution in the high-resolution limit where the grid size is smaller than the particle size. To address this uncertainty, fixed particle beds of two primary configurations were studied: i) fictitious beds where the particles are seeded with a random particle generator, and ii) instantaneous snapshots from a transient simulation of anmore » experimentally relevant problem. Both problems considered a uniform inlet boundary and a pressure outflow. The CFD grid was refined from a few particle diameters down to 1/6 th of a particle diameter. The pressure drop between two vertical elevations, averaged across the bed cross-section was considered as the system response quantity of interest. A least-squares regression method was used to extrapolate the grid-dependent results to an approximate “grid-free” solution in the limit of infinite resolution. The results show that the diffusion based scheme does yield a converging solution. However, the convergence is more complicated than encountered in simpler, single-phase flow problems showing strong oscillations and, at times, oscillations superimposed on top of globally non-monotonic behavior. The challenging convergence behavior highlights the importance of using at least four grid resolutions in solution verification problems so that (over-determined) regression-based extrapolation methods may be applied to approximate the grid-free solution. The grid-free solution is very important in solution verification and VVUQ exercise in general as the difference between it and the reference solution largely determines the numerical uncertainty. By testing different randomized particle configurations of the same general problem (for the fictitious case) or different instances of freezing a transient simulation, the numerical uncertainties appeared to be on the same order of magnitude as ensemble or time averaging uncertainties. By testing different drag laws, almost all cases studied show that model form uncertainty in this one, very important closure relation was larger than the numerical uncertainty, at least with a reasonable CFD grid, roughly five particle diameters. In this study, the diffusion width (filtering length scale) was mostly set at a constant of six particle diameters. A few exploratory tests were performed to show that similar convergence behavior was observed for diffusion widths greater than approximately two particle diameters. However, this subject was not investigated in great detail because determining an appropriate filter size is really a validation question which must be determined by comparison to experimental or highly accurate numerical data. Future studies are being considered targeting solution verification of transient simulations as well as validation of the filter size with direct numerical simulation data.« less
Chen, Ailu; Gall, Elliott T; Chang, Victor W C
2016-09-01
We conducted multiday continuous monitoring of indoor and outdoor particulate matter (PM) in classrooms with fan-assisted natural ventilation (NV) at five primary schools in Singapore. We monitored size-resolved number concentration of PM with diameter 0.3-10 μm at all schools and alveolar deposited surface area concentrations of PM with diameter 0.01-1.0 μm (SA0.01-1.0) at two schools. Results show that, during the monitoring period, schools closer to expressways and in the downtown area had 2-3 times higher outdoor PM0.3-1.0 number concentrations than schools located in suburban areas. Average indoor SA0.01-1.0 was 115-118 μm(2) cm(-3) during periods of occupancy and 72-87 μm(2) cm(-3) during unoccupied periods. There were close indoor and outdoor correlations for fine PM during both occupied and unoccupied periods (Pearson's r = 0.84-1.0) while the correlations for coarse PM were weak during the occupied periods (r = 0.13-0.74). Across all the schools, the size-resolved indoor/outdoor PM ratios (I/O ratios) were 0.81 to 1.58 and 0.61 to 0.95 during occupied and unoccupied periods, respectively, and average infiltration factors were 0.64 to 0.94. Average PM net emission rates, calculated during periods of occupancy in the classrooms, were lower than or in the lower range of emission rates reported in the literature. This study also reveals that indoor fine and submicron PM predominantly come from outdoor sources, while indoor sources associated with occupancy may be important for coarse PM even when the classrooms have high air exchange rates.
Aiken, Allison C.; McMeeking, Gavin R.; Levin, Ezra J. T.; ...
2016-04-05
Refractory black carbon (rBC) is an aerosol that has important impacts on climate and human health. rBC is often mixed with other species, making it difficult to isolate and quantify its important effects on physical and optical properties of ambient aerosol. To solve this measurement challenge, a new method to remove rBC was developed using laser-induced incandescence (LII) by Levin et al. in 2014. Application of the method with the Single Particle Soot Photometer (SP2) is used to determine the effects of rBC on ice nucleating particles (INP). Here, we quantify the efficacy of the method in the laboratory usingmore » the rBC surrogate Aquadag. Polydisperse and mobility-selected samples (100–500 nm diameter, 0.44–36.05 fg), are quantified by a second SP2. Removal rates are reported by mass and number. For the mobility-selected samples, the average percentages removed by mass and number of the original size are 88.9 ± 18.6% and 87.3 ± 21.9%, respectively. Removal of Aquadag is efficient for particles >100 nm mass-equivalent diameter (d me), enabling application for microphysical studies. However, the removal of particles ≤100 nm d me is less efficient. Absorption and scattering measurements are reported to assess its use to isolate brown carbon (BrC) absorption. Scattering removal rates for the mobility-selected samples are >90% on average, yet absorption rates are 53% on average across all wavelengths. Therefore, application to isolate effects of microphysical properties determined by larger sizes is promising, but will be challenging for optical properties. Lastly, the results reported also have implications for other instruments employing internal LII, e.g., the Soot Particle Aerosol Mass Spectrometer (SP-AMS).« less
Meisner, Eric M; Hager, Gregory D; Ishman, Stacey L; Brown, David; Tunkel, David E; Ishii, Masaru
2013-11-01
To evaluate the accuracy of three-dimensional (3D) airway reconstructions obtained using quantitative endoscopy (QE). We developed this novel technique to reconstruct precise 3D representations of airway geometries from endoscopic video streams. This method, based on machine vision methodologies, uses a post-processing step of the standard videos obtained during routine laryngoscopy and bronchoscopy. We hypothesize that this method is precise and will generate assessment of airway size and shape similar to those obtained using computed tomography (CT). This study was approved by the institutional review board (IRB). We analyzed video sequences from pediatric patients receiving rigid bronchoscopy. We generated 3D scaled airway models of the subglottis, trachea, and carina using QE. These models were compared to 3D airway models generated from CT. We used the CT data as the gold standard measure of airway size, and used a mixed linear model to estimate the average error in cross-sectional area and effective diameter for QE. The average error in cross sectional area (area sliced perpendicular to the long axis of the airway) was 7.7 mm(2) (variance 33.447 mm(4)). The average error in effective diameter was 0.38775 mm (variance 2.45 mm(2)), approximately 9% error. Our pilot study suggests that QE can be used to generate precise 3D reconstructions of airways. This technique is atraumatic, does not require ionizing radiation, and integrates easily into standard airway assessment protocols. We conjecture that this technology will be useful for staging airway disease and assessing surgical outcomes. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Levrini, G; Sghedoni, R; Mori, C; Botti, A; Vacondio, R; Nitrosi, A; Iori, M; Nicoli, F
2011-10-01
The aim of this study was to investigate the efficacy of a dedicated software tool for automated volume measurement of breast lesions in contrast-enhanced (CE) magnetic resonance mammography (MRM). The size of 52 breast lesions with a known histopathological diagnosis (three benign, 49 malignant) was automatically evaluated using different techniques. The volume of all lesions was measured automatically (AVM) from CE 3D MRM examinations by means of a computer-aided detection (CAD) system and compared with the size estimates based on maximum diameter measurement (MDM) on MRM, ultrasonography (US), mammography and histopathology. Compared with histopathology as the reference method, AVM understimated lesion size by 4% on average. This result was similar to MDM (3% understimation, not significantly different) but significantly better than US and mammographic lesion measurements (24% and 33% size underestimation, respectively). AVM is as accurate as MDM but faster. Both methods are more accurate for size assessment of breast lesions compared with US and mammography.
Structural phase transitions in SrTiO 3 nanoparticles
Zhang, Han; Liu, Sizhan; Scofield, Megan E.; ...
2017-08-04
We present that pressure dependent structural measurements on monodispersed nanoscale SrTiO 3 samples with average diameters of 10 to ~80 nm were conducted to enhance the understanding of the structural phase diagram of nanoscale SrTiO 3. A robust pressure independent polar structure was found in the 10 nm sample for pressures up to 13 GPa, while a size dependent cubic to tetragonal transition occurs (at P = P c) for larger particle sizes. In conclusion, the results suggest that the growth of ~10 nm STO particles on substrates with significant lattice mismatch may maintain a polar state for a largemore » range of strain values, possibly enabling device use.« less
NASA Astrophysics Data System (ADS)
El-Eskandarany, M. Sherif
2017-05-01
The room-temperature reactive ball milling (RBM) approach was employed to synthesize nanostructured fcc-titanium nitride (TiN) powders, starting from milling hcp-titanium (Ti) powders under 10 bar of a nitrogen gas atmosphere, using a roller mill. During the first and intermediate stage of milling, the agglomerated Ti powders were continuously disintegrated into smaller particles with fresh surfaces. Increasing the RBM time led to an increase in the active-fresh surfaces of Ti, resulting increasing of the mole fraction of TiN against unreacted hcp-Ti. Toward the end of the RBM time (20 h), ultrafine spherical powder (with particles 0.5 μm in diameter) of the fcc-TiN phase was obtained, composed of nanocrystalline grains with an average diameter of 8 nm. The samples obtained after different stages of RBM time were consolidated under vacuum at 1600 °C into cylindrical bulk compacts of 20 mm diameter, using spark plasma sintering technique. These compacts that maintained their nanocrystalline characteristics with an average grain size of 56 nm in diameter, possessed high relative density (above 99% of the theoretical density). The Vickers hardness of the as-consolidated TiN was measured and found to be 22.9 GPa. The modulus of elasticity and shear modulus of bulk TiN were measured by a nondestructive test and found to be 384 and 189 GPa, respectively. In addition, the coefficient of friction of the end-product TiN bulk sample was measured and found to be 0.35.
Observational evidence for the convective transport of dust over the Central United States
NASA Astrophysics Data System (ADS)
Corr, C. A.; Ziemba, L. D.; Scheuer, E.; Anderson, B. E.; Beyersdorf, A. J.; Chen, G.; Crosbie, E.; Moore, R. H.; Shook, M.; Thornhill, K. L.; Winstead, E.; Lawson, R. P.; Barth, M. C.; Schroeder, J. R.; Blake, D. R.; Dibb, J. E.
2016-02-01
Bulk aerosol composition and aerosol size distributions measured aboard the DC-8 aircraft during the Deep Convective Clouds and Chemistry Experiment mission in May/June 2012 were used to investigate the transport of mineral dust through nine storms encountered over Colorado and Oklahoma. Measurements made at low altitudes (<5 km mean sea level (MSL)) in the storm inflow region were compared to those made in cirrus anvils (altitude > 9 km MSL). Storm mean outflow Ca2+ mass concentrations and total coarse (1 µm < diameter < 5 µm) aerosol volume (Vc) were comparable to mean inflow values as demonstrated by average outflow/inflow ratios greater than 0.5. A positive relationship between Ca2+, Vc, ice water content, and large (diameter > 50 µm) ice particle number concentrations was not evident; thus, the influence of ice shatter on these measurements was assumed small. Mean inflow aerosol number concentrations calculated over a diameter range (0.5 µm < diameter < 5.0 µm) relevant for proxy ice nuclei (NPIN) were ~15-300 times higher than ice particle concentrations for all storms. Ratios of predicted interstitial NPIN (calculated as the difference between inflow NPIN and ice particle concentrations) and inflow NPIN were consistent with those calculated for Ca2+ and Vc and indicated that on average less than 10% of the ingested NPIN were activated as ice nuclei during anvil formation. Deep convection may therefore represent an efficient transport mechanism for dust to the upper troposphere where these particles can function as ice nuclei cirrus forming in situ.
The pressure-dependence of the size of extruded vesicles.
Patty, Philipus J; Frisken, Barbara J
2003-08-01
Variations in the size of vesicles formed by extrusion through small pores are discussed in terms of a simple model. Our model predicts that the radius should decrease as the square root of the applied pressure, consistent with data for vesicles extruded under various conditions. The model also predicts dependencies on the pore size used and on the lysis tension of the vesicles being extruded that are consistent with our data. The pore size was varied by using track-etched polycarbonate membranes with average pore diameters ranging from 50 to 200 nm. To vary the lysis tension, vesicles made from POPC (1-palmitoyl-2-oleoyl-sn-glycero-3-phosphatidylcholine), mixtures of POPC and cholesterol, and mixtures of POPC and C(16)-ceramide were studied. The lysis tension, as measured by an extrusion-based technique, of POPC:cholesterol vesicles is higher than that of pure POPC vesicles whereas POPC:ceramide vesicles have lower lysis tensions than POPC vesicles.
Di Marzo, Larissa; Cree, Patrick; Barbano, David M
2016-11-01
Our objective was to develop partial least square models using data from Fourier transform mid-infrared (MIR) spectra to predict the particle size distributions d(0.5) and d(0.9), surface volume mean diameter D[3,2], and volume moment mean diameter D[4,3] of milk fat globules and validate the models. The goal of the study was to produce a method built into the MIR milk analyzer that could be used to warn the instrument operator that the homogenizer is near failure and needs to be replaced to ensure quality of results. Five homogenizers with different homogenization efficiency were used to homogenize pasteurized modified unhomogenized milks and farm raw bulk milks. Homogenized milks were collected from the homogenizer outlet and then run through an MIR milk analyzer without an in-line homogenizer to collect a MIR spectrum. A separate portion of each homogenized milk was analyzed with a laser light-scattering particle size analyzer to obtain reference values. The study was replicated 3 times with 3 independent sets of modified milks and bulk tank farm milks. Validation of the models was done with a set of 34 milks that were not used in the model development. Partial least square regression models were developed and validated for predicting the following milk fat globule particle size distribution parameters from MIR spectra: d(0.5) and d(0.9), surface volume mean diameter D[3,2], and volume moment mean diameter D[4,3]. The basis for the ability to model particle size distribution of milk fat emulsions was hypothesized to be the result of the partial least square modeling detecting absorbance shifts in MIR spectra of milk fat due to the Christiansen effect. The independent sample validation of particle size prediction methods found more variation in d(0.9) and D[4,3] predictions than the d(0.5) and D[3,2] predictions relative to laser light-scattering reference values, and this may be due to variation in particle size among different pump strokes. The accuracy of the d(0.9) prediction for routine quality assurance, to determine if a homogenizer within an MIR milk analyzer was near the failure level [i.e., d(0.9) >1.7µm] and needed to be replaced, is fit-for-purpose. The daily average particle size performance [i.e., d(0.9)] of a homogenizer based on the mean for the day could be used for monitoring homogenizer performance. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Pappas, E; Maris, T G; Papadakis, A; Zacharopoulou, F; Damilakis, J; Papanikolaou, N; Gourtsoyiannis, N
2006-10-01
The aim of this work is to investigate experimentally the detector size effect on narrow beam profile measurements. Polymer gel and magnetic resonance imaging dosimetry was used for this purpose. Profile measurements (Pm(s)) of a 5 mm diameter 6 MV stereotactic beam were performed using polymer gels. Eight measurements of the profile of this narrow beam were performed using correspondingly eight different detector sizes. This was achieved using high spatial resolution (0.25 mm) two-dimensional measurements and eight different signal integration volumes A X A X slice thickness, simulating detectors of different size. "A" ranged from 0.25 to 7.5 mm, representing the detector size. The gel-derived profiles exhibited increased penumbra width with increasing detector size, for sizes >0.5 mm. By extrapolating the gel-derived profiles to zero detector size, the true profile (Pt) of the studied beam was derived. The same polymer gel data were also used to simulate a small-volume ion chamber profile measurement of the same beam, in terms of volume averaging. The comparison between these results and actual corresponding small-volume chamber profile measurements performed in this study, reveal that the penumbra broadening caused by both volume averaging and electron transport alterations (present in actual ion chamber profile measurements) is a lot more intense than that resulted by volume averaging effects alone (present in gel-derived profiles simulating ion chamber profile measurements). Therefore, not only the detector size, but also its composition and tissue equivalency is proved to be an important factor for correct narrow beam profile measurements. Additionally, the convolution kernels related to each detector size and to the air ion chamber were calculated using the corresponding profile measurements (Pm(s)), the gel-derived true profile (Pt), and convolution theory. The response kernels of any desired detector can be derived, allowing the elimination of the errors associated with narrow beam profile measurements.
Pediatric Chest and Abdominopelvic CT: Organ Dose Estimation Based on 42 Patient Models
Tian, Xiaoyu; Li, Xiang; Segars, W. Paul; Paulson, Erik K.; Frush, Donald P.
2014-01-01
Purpose To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. Materials and Methods The institutional review board approved this HIPAA–compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0–16 years; weight range, 2–80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDIvol). The relationships between CTDIvol-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. Results For organs within the image coverage, CTDIvol-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R2 > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%–32%) mainly because of the effect of overranging. Conclusion It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDIvol. These CTDIvol-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice. © RSNA, 2013 PMID:24126364
Cumulative frequency distribution of past species extinctions
NASA Technical Reports Server (NTRS)
Raup, D. M.
1991-01-01
Analysis of Sepkoski's compendium of the time ranges of 30,000+ taxa yields a mean duration of 28.4 ma for genera of fossil invertebrates. This converts to an average extinction rate of 3.5 percent per million years or about one percent every 286,000 years. Using survivorship techniques, these estimates can be converted to the species level, yielding a Phanerozoic average of one percent species extinction every 40,000 years. Variation in extinction rates through time is far greater than the null expectation of a homogeneous birth-death model and this reflects the well-known episodicity of extinction ranging from a few large mass extinctions to so-called background extinction. The observed variation in rates can be used to construct a cumulative frequency distribution of extinction intensity, and this distribution, in the form of a kill curve for species, shows the expected waiting times between extinction events of a given intensity. The kill curve is an average description of the extinction events of a given intensity. The kill curve is an average description of the extinction record and does not imply any cause or causes of extinction. The kill curve shows, among other things, that only about five percent of total species extinctions in the Phanerozoic were involved in the five largest mass extinctions. The other 95 percent were distributed among large and small events not normally called mass extinctions. As an exploration of the possibly absurd proposition that most past extinctions were produced by the effects of large-body impact, the kill curve for species was mapped on the comparable distribution for comet and asteroid impacts. The result is a curve predicting the species kill for a given size of impacting object (expressed as crater size). The results are reasonable in that impacts producing craters less than 30 km (diameter) cause negligible extinction but those producing craters 100-150 km (diameter) cause extinction of species in the range of 45-60 percent.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pesavento, J B; Morgan, D; Bermingham, R
Nanolipoprotein particles (NLPs) are small 10-20 nm diameter assemblies of apolipoproteins and lipids. At Lawrence Livermore National Laboratory (LLNL), they have constructed multiple variants of these assemblies. NLPs have been generated from a variety of lipoproteins, including apolipoprotein Al, apolipophorin III, apolipoprotein E4 22K, and MSP1T2 (nanodisc, Inc.). Lipids used included DMPC (bulk of the bilayer material), DMPE (in various amounts), and DPPC. NLPs were made in either the absence or presence of the detergent cholate. They have collected electron microscopy data as a part of the characterization component of this research. Although purified by size exclusion chromatography (SEC), samplesmore » are somewhat heterogeneous when analyzed at the nanoscale by negative stained cryo-EM. Images reveal a broad range of shape heterogeneity, suggesting variability in conformational flexibility, in fact, modeling studies point to dynamics of inter-helical loop regions within apolipoproteins as being a possible source for observed variation in NLP size. Initial attempts at three-dimensional reconstructions have proven to be challenging due to this size and shape disparity. They are pursuing a strategy of computational size exclusion to group particles into subpopulations based on average particle diameter. They show here results from their ongoing efforts at statistically and computationally subdividing NLP populations to realize greater homogeneity and then generate 3D reconstructions.« less
Statistical properties of the ice particle distribution in stratiform clouds
NASA Astrophysics Data System (ADS)
Delanoe, J.; Tinel, C.; Testud, J.
2003-04-01
This paper presents an extensive analysis of several microphysical data bases CEPEX, EUCREX, CLARE and CARL to determine statistical properties of the Particle Size Distribution (PSD). The data base covers different type of stratiform clouds : tropical cirrus (CEPEX), mid-latitude cirrus (EUCREX) and mid-latitude cirrus and stratus (CARL,CLARE) The approach for analysis uses the concept of normalisation of the PSD developed by Testud et al. (2001). The normalization aims at isolating three independent characteristics of the PSD : its "intrinsic" shape, the "average size" of the spectrum and the ice water content IWC, "average size" is meant the mean mass weighted diameter. It is shown that concentration should be normalized by N_0^* proportional to IWC/D_m^4. The "intrinsic" shape is defined as F(Deq/D_m)=N(Deq)/N_0^* where Deq is the equivalent melted diameter. The "intrinsic" shape is found to be very stable in the range 00
Lanzerstorfer, Christof
2015-04-01
For the handling, treatment and utilization of fly ash from biomass combustion its chemical composition and physical properties are important. In this study eight filter fly ashes from different grate-fired biomass combustion plants were investigated. In fly ash from straw combustion high concentrations of (K) were found, whereas in the fly ash from wood combustion the concentrations of Ca and Mg were higher. The average concentration of PO4(3-) was similar in both types of fly ashes. In all wood fly ashes some measured heavy metal concentrations were above the limits for utilization. The straw fly ashes were much less contaminated and can be utilized. For wood fly ash most parameters showed little variation, except from one fly ash where the dust pre-separator is in poor condition. The average values were: mass median diameter 4.3±0.8 μm, spread of particle size distribution 19±11, particle density 2620±80 kg/m3 and angle of repose 50°±1°. The density of the straw fly ashes is lower (2260±80 kg/m3) and the spread of the size distribution is higher (72±24). For one straw combustion fly ash the values of the mass median diameter and the angle of repose were similar to the values of wood combustion fly ash, for the other straw fly ash the values differed considerably. While the particle size of this fly ash was much smaller, surprisingly the angle of repose was also lower. This can be attributed to the formation of small agglomerates in this fly ash, which were not disintegrated without a certain stress. Copyright © 2015. Published by Elsevier B.V.
Impact of solvent granularity and layering on tracer hydrodynamics in confinement.
Bollinger, Jonathan A; Carmer, James; Jain, Avni; Truskett, Thomas M
2016-11-28
Classic hydrodynamic arguments establish that when a spherical tracer particle is suspended between parallel walls, tracer-wall coupling mediated by the solvent will cause the tracer to exhibit position-dependent diffusivity. We investigate how the diffusivity profiles of confined tracers are impacted by the diameter size-ratio of the tracer to solvent: starting from the classic limit of infinite size-ratio (i.e., continuum solvent), we consider size-ratios of four or less to examine how hydrodynamic predictions are disrupted for systems where the tracer and solvent are of similar scale. We use computer simulations and techniques based on the Fokker-Planck formalism to calculate the diffusivity profiles of hard-sphere tracer particles in hard-sphere solvents, focusing on the dynamics perpendicular to the walls. Given wall separations of several tracer diameters, we first consider confinement between hard walls, where anisotropic structuring at the solvent lengthscale generates inhomogeneity in the tracer free-energy landscape and undermines hydrodynamic predictions locally. We then introduce confining planes that we term transparent walls, which restrict tracer and solvent center-accessibilities while completely eliminating static anisotropy, and reveal position-dependent signatures in tracer diffusivity solely attributable to confinement. With or without suppressing static heterogeneity, we find that tracer diffusivity increasingly deviates on a local basis from hydrodynamic predictions at smaller size-ratios. However, hydrodynamic theory still approximately captures spatially-averaged dynamics across the pores even for very small tracer-solvent size-ratios over a wide range of solvent densities and wall separations.
DIRECT COUNTING AND SIZING OF MITOCHONDRIA IN SOLUTION
Gear, Adrian R. L.; Bednarek, Jana M.
1972-01-01
Resistive particle counting has been developed for the accurate sizing and counting of mitochondria in solution. The normal detection limit with a 30 µ aperture is 0.48 µ diameter, or 0.056 µ3 particle volume The mean volume of rat liver mitochondria was 0.42 µ3 or 0.93 µ in diameter. The average value for numbers of particles per milligram of mitochondrial protein was 4.3 x 103, and per gram of rat liver was about 11 x 1010. These values compare satisfactorily with those derived by light microscopy and electron microscopy. The mean volume for mitochondria from rat heart was 0 60 µ3 and from rat kidney cortex, 0.23 µ3. These values agree within 15% of those determined by electron microscopy of whole tissue. Mitochondrial fragility and contaminating subcellular organelles were shown to have little influence on the experimentally determined size distributions The technique may be applied to rapid swelling studies, as well as to estimations of the number and size of mitochondria from animals under different conditions such as liver regeneration and hormonal, pathological, or drug-induced states Mitochondrial DNA, RNA, cytochrome c-oxidase, cytochrome (a ÷ a 3), and iron were nearly constant per particle over large differences in particle size. Such data may be particularly valuable for biogenesis studies and support the hypothesis that the net amount per particle of certain mitochondrial constituents remains constant during mitochondrial growth and enlargement PMID:4339279
NASA Astrophysics Data System (ADS)
Kurokawa, Yusaku; Taki, Hirofumi; Yashiro, Satoshi; Nagasawa, Kan; Ishigaki, Yasushi; Kanai, Hiroshi
2016-07-01
We propose a method for assessment of the degree of red blood cell (RBC) aggregation using the backscattering property of high-frequency ultrasound. In this method, the scattering property of RBCs is extracted from the power spectrum of RBC echoes normalized by that from the posterior wall of a vein. In an experimental study using a phantom, employing the proposed method, the sizes of microspheres 5 and 20 µm in diameter were estimated to have mean values of 4.7 and 17.3 µm and standard deviations of 1.9 and 1.4 µm, respectively. In an in vivo experimental study, we compared the results between three healthy subjects and four diabetic patients. The average estimated scatterer diameters in healthy subjects at rest and during avascularization were 7 and 28 µm, respectively. In contrast, those in diabetic patients receiving both antithrombotic therapy and insulin therapy were 11 and 46 µm, respectively. These results show that the proposed method has high potential for clinical application to assess RBC aggregation, which may be related to the progress of diabetes.
NASA Astrophysics Data System (ADS)
Strohm, Eric; Rui, Min; Gorelikov, Ivan; Matsuura, Naomi; Kolios, Michael
2011-03-01
An acoustic and photoacoustic characterization of micron-sized perfluorocarbon (PFC) droplets is presented. PFC droplets are currently being investigated as acoustic and photoacoustic contrast agents and as cancer therapy agents. Pulse echo measurements at 375 MHz were used to determine the diameter, ranging from 3.2 to 6.5 μm, and the sound velocity, ranging from 311 to 406 m/s of nine droplets. An average sound velocity of 379 +/- 18 m/s was calculated for droplets larger than the ultrasound beam width of 4.0 μm. Optical droplet vaporization, where vaporization of a single droplet occurred upon laser irradiation of sufficient intensity, was verified using pulse echo acoustic methods. The ultrasonic backscatter amplitude, acoustic impedance and attenuation increased after vaporization, consistent with a phase change from a liquid to gas core. Photoacoustic measurements were used to compare the spectra of three droplets ranging in diameter from 3.0 to 6.2 μm to a theoretical model. Good agreement in the spectral features was observed over the bandwidth of the 375 MHz transducer.
NASA Astrophysics Data System (ADS)
La Fontaine, A.; Coleman, V. A.; Jämting, A. K.; Lawn, M.; Herrmann, J.; Miles, J. R.
2010-06-01
Three different methods for extracting zinc oxide (ZnO) and titanium dioxide (TiO2) nanoparticles from commercially available sunscreen were investigated to determine the most appropriate route for producing a sample suitable for measuring the primary particle size. Direct dilution of the formulation, centrifugal methods and chemical washing were trialed in combination with ultrasonic processing and surfactant addition to generate samples that are suitable for particle size analysis. Transmission electron microscopy (TEM) and dynamic light scattering (DLS) were used to monitor the extraction and re-dispersion process. Washing with hexane, methanol and water to remove the formulation, in combination with pulsed high-powered ultrasonication and the addition of a charge-stabilizing surfactant was found to be the most efficient way of producing de-agglomerated samples. DLS measurements gave average hydrodynamic particle diameters of 87 nm for ZnO and 76 nm for TiO2, compared to equivalent spherical particle diameters of 21 +/- 12 nm for ZnO (81 particles) and 19 +/- 14 nm for TiO2 (81 particles) obtained from TEM analysis.
Experimental study of cryogen spray properties for application in dermatologic laser surgery.
Aguilar, Guillermo; Majaron, Boris; Karapetian, Emil; Lavernia, Enrique J; Nelson, J Stuart
2003-07-01
Cryogenic sprays are used for cooling human skin during laser dermatologic surgery. In this paper, six straight-tube nozzles are characterized by photographs of cryogenic spray shapes, as well as measurements of average droplet diameter, velocity, and temperature. A single-droplet evaporation model to predict average spray droplet diameter and temperature is tested using the experimental data presented here. The results show two distinct spray patterns--sprays for 1.4-mm-diameter nozzles (wide nozzles) show significantly larger average droplet diameters and higher temperatures as a function of distance from the nozzle compared with those for 0.5-0.8-mm-diameter nozzles (narrow nozzles). These results complement and support previously reported studies, indicating that wide nozzles induce more efficient heat extraction than the narrow nozzles.
Does endothelial cell density correlate with corneal diameter in a group of young adults?
Giasson, Claude J; Gosselin, Lucie; Masella, Aviva; Forcier, Pierre
2008-07-01
In children, but not in the elderly, an association exists between corneal diameter and endothelial cell density (ECD). We tested whether such an association also held true in young adults. The eyes of 35 healthy subjects (mean age, 23.1 +/- 3.1 years) were photographed by using a video camera and a noncontact endothelial microscope. Both sets of images were analyzed with image software and the contour method to measure corneal diameter, ECD, and endothelial coefficients. Axial lengths, refractive errors, and corneal curvatures were measured by using an A-scan ultrasonic biometer and kerato-refractometer. Measurements, averaged for the right and left eyes, were analyzed depending on (1) use of contact lenses, (2) ametropia, and on whether (3) axial length or (4) corneal diameter was above or below group means. Differences were tested for statistical significance with independent t tests and association with the Pearson correlation coefficient. ECD, corneal diameter, and spherical equivalent refraction were 3022 +/- 262 cells/mm2, 12.0 +/- 0.5 mm, and -3.1 +/- 2.5 D, respectively. The only significant differences between wearers and nonwearers of contact lenses were the spherical refractive equivalent and axial length. There was no correlation between ECD and corneal diameter or axial length. As opposed to previously reported results in children, but as found in the elderly, there is no correlation between ECD and corneal diameter in young adults. Therefore, corneal size cannot be considered a determinant of ECD in young adults.
Anderson, P J; Wilson, J D; Hiller, F C
1989-07-01
Accurate measurement of cigarette smoke particle size distribution is important for estimation of lung deposition. Most prior investigators have reported a mass median diameter (MMD) in the size range of 0.3 to 0.5 micron, with a small geometric standard deviation (GSD), indicating few ultrafine (less than 0.1 micron) particles. A few studies, however, have suggested the presence of ultrafine particles by reporting a smaller count median diameter (CMD). Part of this disparity may be due tot he inefficiency to previous sizing methods in measuring ultrafine size range, to evaluate size distribution of smoke from standard research cigarettes, commercial filter cigarettes, and from marijuana cigarettes with different delta 9-tetrahydrocannabinol contents. Four 35-cm3, 2-s puffs were generated at 60-s intervals, rapidly diluted, and passed through a charge neutralizer and into a 240-L chamber. Size distribution for six cigarettes of each type was measured, CMD and GSD were determined from a computer-generated log probability plot, and MMD was calculated. The size distribution parameters obtained were similar for all cigarettes tested, with an average CMD of 0.1 micron, a MMD of 0.38 micron, and a GSD of 2.0. The MMD found using the EAA is similar to that previously reported, but the CMD is distinctly smaller and the GSD larger, indicating the presence of many more ultrafine particles. These results may explain the disparity of CMD values found in existing data. Ultrafine particles are of toxicologic importance because their respiratory tract deposition is significantly higher than for particles 0.3 to 0.5 micron and because their large surface area facilitates adsorption and delivery of potentially toxic gases to the lung.
Dong, Ling-Bo; Liu, Zhao-Gang; Li, Feng-Ri; Jiang, Li-Chun
2013-09-01
By using the branch analysis data of 955 standard branches from 60 sampled trees in 12 sampling plots of Pinus koraiensis plantation in Mengjiagang Forest Farm in Heilongjiang Province of Northeast China, and based on the linear mixed-effect model theory and methods, the models for predicting branch variables, including primary branch diameter, length, and angle, were developed. Considering tree effect, the MIXED module of SAS software was used to fit the prediction models. The results indicated that the fitting precision of the models could be improved by choosing appropriate random-effect parameters and variance-covariance structure. Then, the correlation structures including complex symmetry structure (CS), first-order autoregressive structure [AR(1)], and first-order autoregressive and moving average structure [ARMA(1,1)] were added to the optimal branch size mixed-effect model. The AR(1) improved the fitting precision of branch diameter and length mixed-effect model significantly, but all the three structures didn't improve the precision of branch angle mixed-effect model. In order to describe the heteroscedasticity during building mixed-effect model, the CF1 and CF2 functions were added to the branch mixed-effect model. CF1 function improved the fitting effect of branch angle mixed model significantly, whereas CF2 function improved the fitting effect of branch diameter and length mixed model significantly. Model validation confirmed that the mixed-effect model could improve the precision of prediction, as compare to the traditional regression model for the branch size prediction of Pinus koraiensis plantation.
Filho, Walter Duarte de Araujo; Schneider, Fábio Kurt; Morales, Rigoberto E M
2012-09-20
Micro bubbles were initially introduced as contrast agents for ultrasound examinations as they are able to modify the signal-to-noise ratio in imaging, thus improving the assessment of clinical information on human tissue. Recent developments have demonstrated the feasibility of using these bubbles as drug carriers in localized delivery. In micro fluidics devices for generation of micro bubbles, the bubbles are formed at interface of liquid gas through a strangulation process. A device that uses these features can produce micro bubbles with small size dispersion in a single step. A T-junction micro fluidic device constructed using 3D prototyping was made for the production of mono dispersed micro bubbles. These micro bubbles use sunflower oil as a lipid layer. Stability studies for micro bubbles with diameters different generated from a liquid phase of the same viscosity were conducted to evaluate whether micro bubbles can be used as drug carriers. The biocompatibility of coating layer, the ability to withstand environmental pressure variations combined with echogenicity, are key factors that they can safely play the role of drug transporters. The normal distribution curve with small dispersion of the diameter of bubbles validates the process of generating micro bubbles with low value of variation coefficient, i.e., 0.381 at 1.90%. The results also showed the feasibility of using sunflower oil as the lipid matrix with stable population of bubbles over 217 minutes for micro bubbles with an average diameter of 313.04 μm and 121 minutes for micro bubbles with an average diameter of 73.74 μm, considering bubbles with air as gaseous phase. The results indicate that the micro fluidic device designed can be used for producing micro bubbles with low variation coefficient using sunflower oil as a coating of micro bubbles. These carriers were stable for periods of time that are long enough for clinical applications even when regular air is used as the gas phase. Improved stability can be achieved when biocompatible gas with lower permeability is used.
Survival and growth of black walnut families after 7 years in West Virginia
G. W. Wendel; Donald E. Dorn; Donald E. Dorn
1985-01-01
Average survival, 7-year stem diameter, and stem diameter growth differed significantly among 34 black walnut families planted in West Virginia. Average total height, height growth, and diameter at breast height were not significantly different among families. Families were from seed collected in West Virginia, Pennsylvania, North Carolina, and Tennessee. The 7-year...
Height diameter relations of maple street trees
David J. Nowak
1990-01-01
Height and diameter measurements were taken for silver, sugar and Norway maple street trees in Rochester and Syracuse, New York. Mature silver maples proved to be the tallest of the three species. Average sugar maple height was consistently taller than Norway maple height until diameters reached 28 inches. Average mature tree height for all three species level off in...
Williams, Jackie M.; Krebs, Ingar A.; Riedesel, Elizabeth A.; Zhao, Qianqian
2015-01-01
Tracheal collapse is a progressive airway disease that can ultimately result in complete airway obstruction. Intraluminal tracheal stents are a minimally invasive and viable treatment for tracheal collapse once the disease becomes refractory to medical management. Intraluminal stent size is chosen based on the maximum measured tracheal diameter during maximum inflation. The purpose of this prospective, cross-sectional study was to compare tracheal lumen diameter measurements and subsequent selected stent size using both fluoroscopy and CT and to evaluate inter- and intraobserver variability of the measurements. Seventeen healthy Beagles were anesthetized and imaged with fluoroscopy and CT with positive pressure ventilation to 20 cm H2O. Fluoroscopic and CT maximum tracheal diameters were measured by 3 readers. Three individual measurements were made at 8 pre-determined tracheal sites for dorsoventral (height) and laterolateral (width) dimensions. Tracheal diameters and stent sizes (based on the maximum tracheal diameter + 10%) were analyzed using a linear mixed model. CT tracheal lumen diameters were larger compared to fluoroscopy at all locations. When comparing modalities, fluoroscopic and CT stent sizes were statistically different. Greater overall variation in tracheal diameter measurement (height or width) existed for fluoroscopy compared to CT, both within and among observers. The greater tracheal diameter and lower measurement variability supported the use of CT for appropriate stent selection to minimize complications in veterinary patients. PMID:26784924
Catalyst support of mixed cerium zirconium titanium oxide, including use and method of making
Willigan, Rhonda R [Manchester, CT; Vanderspurt, Thomas Henry [Glastonbury, CT; Tulyani, Sonia [Manchester, CT; Radhakrishnan, Rakesh [Vernon, CT; Opalka, Susanne Marie [Glastonbury, CT; Emerson, Sean C [Broad Brook, CT
2011-01-18
A durable catalyst support/catalyst is capable of extended water gas shift operation under conditions of high temperature, pressure, and sulfur levels. The support is a homogeneous, nanocrystalline, mixed metal oxide of at least three metals, the first being cerium, the second being Zr, and/or Hf, and the third importantly being Ti, the three metals comprising at least 80% of the metal constituents of the mixed metal oxide and the Ti being present in a range of 5% to 45% by metals-only atomic percent of the mixed metal oxide. The mixed metal oxide has an average crystallite size less than 6 nm and forms a skeletal structure with pores whose diameters are in the range of 4-9 nm and normally greater than the average crystallite size. The surface area of the skeletal structure per volume of the material of the structure is greater than about 240 m.sup.2/cm.sup.3. The method of making and use are also described.
Gavino, V C; Milo, G E; Cornwell, D G
1982-03-01
Image analysis was used for the automated measurement of colony frequency (f) and colony diameter (d) in cultures of smooth muscle cells, Initial studies with the inverted microscope showed that number of cells (N) in a colony varied directly with d: log N = 1.98 log d - 3.469 Image analysis generated the complement of a cumulative distribution for f as a function of d. The number of cells in each segment of the distribution function was calculated by multiplying f and the average N for the segment. These data were displayed as a cumulative distribution function. The total number of colonies (fT) and the total number of cells (NT) were used to calculate the average colony size (NA). Population doublings (PD) were then expressed as log2 NA. Image analysis confirmed previous studies in which colonies were sized and counted with an inverted microscope. Thus, image analysis is a rapid and automated technique for the measurement of clonal growth.
Photoacoustic spectral characterization of perfluorocarbon droplets
NASA Astrophysics Data System (ADS)
Strohm, Eric; Gorelikov, Ivan; Matsuura, Naomi; Kolios, Michael
2012-02-01
Perfluorocarbon droplets containing optical absorbing nanoparticles have been developed for use as theranostic agents (for both imaging and therapy) and as dual-mode contrast agents. Droplets can be used as photoacoustic contrast agents, vaporized via optical irradiation, then the resulting bubbles can be used as ultrasound imaging and therapeutic agents. The photoacoustic signals from micron-sized droplets containing silica coated gold nanospheres were measured using ultra-high frequencies (100-1000 MHz). The spectra of droplets embedded in a gelatin phantom were compared to a theoretical model which calculates the pressure wave from a spherical homogenous liquid undergoing thermoelastic expansion resulting from laser absorption. The location of the spectral features of the theoretical model and experimental spectra were in agreement after accounting for increases in the droplet sound speed with frequency. The agreement between experiment and model indicate that droplets (which have negligible optical absorption in the visible and infrared spectra by themselves) emitted pressure waves related to the droplet composition and size, and was independent of the physical characteristics of the optical absorbing nanoparticles. The diameter of individual droplets was calculated using three independent methods: the time domain photoacoustic signal, the time domain pulse echo ultrasound signal, and a fit to the photoacoustic model, then compared to the diameter as measured by optical microscopy. It was found the photoacoustic and ultrasound methods calculated diameters an average of 2.6% of each other, and 8.8% lower than that measured using optical microscopy. The discrepancy between the calculated diameters and the optical measurements may be due to the difficulty in resolving the droplet edges after being embedded in the translucent gelatin medium.
Neff, Jason C.; Reynolds, Richard L.; Munson, Seth M.; Fernandez, Daniel; Belnap, Jayne
2013-01-01
Mineral aerosols are produced during the erosion of soils by wind and are a common source of particles (dust) in arid and semiarid regions. The size of these particles varies widely from less than 2 µm to larger particles that can exceed 50 µm in diameter. In this study, we present two continuous records of total suspended particle (TSP) concentrations at sites in Mesa Verde and Canyonlands National Parks in Colorado and Utah, USA, respectively, and compare those values to measurements of fine and coarse particle concentrations made from nearby samplers. Average annual concentrations of TSP at Mesa Verde were 90 µg m−3 in 2011 and at Canyonlands were 171 µg m−3 in 2009, 113 µg m−3 in 2010, and 134 µg m−3 in 2011. In comparison, annual concentrations of fine (diameter of 2.5 µm and below) and coarse (2.5–10 µm diameter) particles at these sites were below 10 µg m−3 in all years. The high concentrations of TSP appear to be the result of regional dust storms with elevated concentrations of particles greater than 10 µm in diameter. These conditions regularly occur from spring through fall with 2 week mean TSP periodically in excess of 200 µg m−3. Measurement of particles on filters indicates that the median particle size varies between approximately 10 µm in winter and 40 µm during the spring. These persistently elevated concentrations of large particles indicate that regional dust emission as dust storms and events are important determinants of air quality in this region.
Shape, size and multiplicity of main-belt asteroids I. Keck Adaptive Optics survey
Marchis, F.; Kaasalainen, M.; Hom, E.F.Y.; Berthier, J.; Enriquez, J.; Hestroffer, D.; Le Mignant, D.; de Pater, I.
2008-01-01
This paper presents results from a high spatial resolution survey of 33 main-belt asteroids with diameters >40 km using the Keck II Adaptive Optics (AO) facility. Five of these (45 Eugenia, 87 Sylvia, 107 Camilla, 121 Hermione, 130 Elektra) were confirmed to have satellite. Assuming the same albedo as the primary, these moonlets are relatively small (∼5% of the primary size) suggesting that they are fragments captured after a disruptive collision of a parent body or captured ejecta due to an impact. For each asteroid, we have estimated the minimum size of a moonlet that can positively detected within the Hill sphere of the system by estimating and modeling a 2-σ detection profile: in average on the data set, a moonlet located at 2/100 × RHill (1/4 × RHill) with a diameter larger than 6 km (4 km) would have been unambiguously seen. The apparent size and shape of each asteroid was estimated after deconvolution using a new algorithm called AIDA. The mean diameter for the majority of asteroids is in good agreement with IRAS radiometric measurements, though for asteroids with a D < 200 km, it is underestimated on average by 6–8%. Most asteroids had a size ratio that was very close to those determined by lightcurve measurements. One observation of 104 Klymene suggests it has a bifurcated shape. The bi-lobed shape of 121 Hermione described in Marchis et al. [Marchis, F., Hestroffer, D., Descamps, P., Berthier, J., Laver, C., de Pater, I., 2005c. Icarus 178, 450–464] was confirmed after deconvolution. The ratio of contact binaries in our survey, which is limited to asteroids larger than 40 km, is surprisingly high (∼6%), suggesting that a non-single configuration is common in the main-belt. Several asteroids have been analyzed with lightcurve inversions. We compared lightcurve inversion models for plane-of-sky predictions with the observed images (9 Metis, 52 Europa, 87 Sylvia, 130 Elektra, 192 Nausikaa, and 423 Diotima, 511 Davida). The AO images allowed us to determine a unique photometric mirror pole solution, which is normally ambiguous for asteroids moving close to the plane of the ecliptic (e.g., 192 Nausikaa and 52 Europa). The photometric inversion models agree well with the AO images, thus confirming the validity of both the lightcurve inversion method and the AO image reduction technique. PMID:19081813
The influence of plain bar on bond strength of geopolymer concrete
NASA Astrophysics Data System (ADS)
Dewi, Evrianti Syntia; Ekaputri, Januarti Jaya
2017-06-01
This paper presents some results of experimental study of bond strength of plain bar embedded in geopolymer concrete. Fly ash class F was used as a raw material activated with alkali solutions. The combination of 8 Molar of sodium hydroxide (NaOH) and sodium silicate (Na2SiO3) as alkali activators was examined in the mixture with ratio of 2.5 by weight. Nine cubical specimens with a size of 150 × 150 × 150 mm were prepared to measure bond strength and slip between reinforcement and concrete. The influential factors studied for the experimental investigation were the diameter of reinforcement bar, bond area, and concrete cover to diameter (c/d) of reinforcement. The result showed that the average bond strength decreased as the diameter of plain bar and bonded length were increased from 16 mm to 19 mm. However, the 12 mm showed the different result allegedly caused by the effect of bond area and the passive confined provided by the concrete. Based on several equations used to compare the bond strength, it is clear that deformed bar of 12 mm in diameter is potential to increase the bond strength.
Hydrogeologic unit map of the Piedmont and Blue Ridge provinces of North Carolina
Daniel, Charles C.; Payne, R.A.
1990-01-01
The numerous geologic formations and rock types in the Piedmont and Blue Ridge provinces of North Carolina have been grouped into 21 hydrogeologic units on the basis of their water-bearing potential as determined from rock origin, composition, and texture. All major classes of rocks--metamorphic, igneous, and sedimentary--are present, although metamorphic rocks are the most abundant. The origin of the hydrogeologic units is indicated by the rock class or subclass (metaigneous, metavolanic, or metasedimentary). The composition of the igneous, metaigneous, and metavolcanic rocks is designated as felsic, intermediate, or mafic except for the addition in the metavolcanic group of epiclastic rocks and compositionally undifferentiated rocks. Composition is the controlling attribute in the classification of the metasedimentary units of gneiss (mafic or felsic), marble, quartzite. The other metasediments are designated primarily on the basis of texture (grain size, degree of metamorphism, and development of foliation). Sedimentary rocks occur in the Piedmont in several downfaulted basins. A computerized data file containing records from more than 6,200 wells was analyzed to determine average well yields in each of the 21 units. The well yields were adjusted to an average well depth of 154 feet and an average diameter of 6 inches, the average of all wells in the data set, to remove the variation in well yield attributed to differences in depth and diameter. Average yields range from a high of 23.6 gallons per minute for schist to a low 11.6 gallons per minute for sedimentary rocks of Triassic age.
Sub-Airy Confocal Adaptive Optics Scanning Ophthalmoscopy.
Sredar, Nripun; Fagbemi, Oladipo E; Dubra, Alfredo
2018-04-01
To demonstrate the viability of improving transverse image resolution in reflectance scanning adaptive optics ophthalmoscopy using sub-Airy disk confocal detection. The foveal cone mosaic was imaged in five human subjects free of known eye disease using two custom adaptive optics scanning light ophthalmoscopes (AOSLOs) in reflectance with 7.75 and 4.30 mm pupil diameters. Confocal pinholes of 0.5, 0.6, 0.8, and 1.0 Airy disk diameters (ADDs) were used in a retinal conjugate plane before the light detector. Average cone photoreceptor intensity profile width and power spectrum were calculated for the resulting images. Detected energy using a model eye was recorded for each pinhole size. The cone photoreceptor mosaic is better resolved with decreasing confocal pinhole size, with the high spatial frequency content of the images enhanced in both the large- and small-pupil AOSLOs. The average cone intensity profile width was reduced by ∼15% with the use of a 0.5 ADD pinhole when compared to a 1.0 ADD, with an accompanying reduction in signal greater than a factor of four. The use of sub-Airy disk confocal pinhole detection without increasing retinal light exposure results in a substantial improvement in image resolution at the cost of larger than predicted signal reduction. Improvement in transverse resolution using sub-Airy disk confocal detection is a practical and low-cost approach that is applicable to all point- and line-scanning ophthalmoscopes, including optical coherence tomographers.
Sub-Airy Confocal Adaptive Optics Scanning Ophthalmoscopy
Sredar, Nripun; Fagbemi, Oladipo E.
2018-01-01
Purpose To demonstrate the viability of improving transverse image resolution in reflectance scanning adaptive optics ophthalmoscopy using sub-Airy disk confocal detection. Methods The foveal cone mosaic was imaged in five human subjects free of known eye disease using two custom adaptive optics scanning light ophthalmoscopes (AOSLOs) in reflectance with 7.75 and 4.30 mm pupil diameters. Confocal pinholes of 0.5, 0.6, 0.8, and 1.0 Airy disk diameters (ADDs) were used in a retinal conjugate plane before the light detector. Average cone photoreceptor intensity profile width and power spectrum were calculated for the resulting images. Detected energy using a model eye was recorded for each pinhole size. Results The cone photoreceptor mosaic is better resolved with decreasing confocal pinhole size, with the high spatial frequency content of the images enhanced in both the large- and small-pupil AOSLOs. The average cone intensity profile width was reduced by ∼15% with the use of a 0.5 ADD pinhole when compared to a 1.0 ADD, with an accompanying reduction in signal greater than a factor of four. Conclusions The use of sub-Airy disk confocal pinhole detection without increasing retinal light exposure results in a substantial improvement in image resolution at the cost of larger than predicted signal reduction. Translational Relevance Improvement in transverse resolution using sub-Airy disk confocal detection is a practical and low-cost approach that is applicable to all point- and line-scanning ophthalmoscopes, including optical coherence tomographers. PMID:29629239
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solomon, Justin, E-mail: justin.solomon@duke.edu; Wilson, Joshua; Samei, Ehsan
2015-08-15
Purpose: The purpose of this work was to assess the inherent image quality characteristics of a new multidetector computed tomography system in terms of noise, resolution, and detectability index as a function of image acquisition and reconstruction for a range of clinically relevant settings. Methods: A multisized image quality phantom (37, 30, 23, 18.5, and 12 cm physical diameter) was imaged on a SOMATOM Force scanner (Siemens Medical Solutions) under variable dose, kVp, and tube current modulation settings. Images were reconstructed with filtered back projection (FBP) and with advanced modeled iterative reconstruction (ADMIRE) with iterative strengths of 3, 4, andmore » 5. Image quality was assessed in terms of the noise power spectrum (NPS), task transfer function (TTF), and detectability index for a range of detection tasks (contrasts of approximately 45, 90, 300, −900, and 1000 HU, and 2–20 mm diameter) based on a non-prewhitening matched filter model observer with eye filter. Results: Image noise magnitude decreased with decreasing phantom size, increasing dose, and increasing ADMIRE strength, offering up to 64% noise reduction relative to FBP. Noise texture in terms of the NPS was similar between FBP and ADMIRE (<5% shift in peak frequency). The resolution, based on the TTF, improved with increased ADMIRE strength by an average of 15% in the TTF 50% frequency for ADMIRE-5. The detectability index increased with increasing dose and ADMIRE strength by an average of 55%, 90%, and 163% for ADMIRE 3, 4, and 5, respectively. Assessing the impact of mA modulation for a fixed average dose over the length of the phantom, detectability was up to 49% lower in smaller phantom sections and up to 26% higher in larger phantom sections for the modulated scan compared to a fixed tube current scan. Overall, the detectability exhibited less variability with phantom size for modulated scans compared to fixed tube current scans. Conclusions: Image quality increased with increasing dose and decreasing phantom size. The CT system exhibited nonlinear noise and resolution properties, especially at very low-doses, large phantom sizes, and for low-contrast objects. Objective image quality metrics generally increased with increasing dose and ADMIRE strength, and with decreasing phantom size. The ADMIRE algorithm could offer comparable image quality at reduced doses or improved image quality at the same dose. The use of tube current modulation resulted in more consistent image quality with changing phantom size.« less
Experimental Investigation of Unsteady Thrust Augmentation Using a Speaker-Driven Jet
NASA Technical Reports Server (NTRS)
Paxson, Daniel E.; Wernet, Mark P.; John, Wentworth T.
2007-01-01
An experimental investigation is described in which a simple speaker-driven jet was used as a pulsed thrust source (driver) for an ejector configuration. The objectives of the investigation were twofold. The first was to expand the experimental body of evidence showing that an unsteady thrust source, combined with a properly sized ejector generally yields higher thrust augmentation values than a similarly sized, steady driver of equivalent thrust. The second objective was to identify characteristics of the unsteady driver that may be useful for sizing ejectors, and for predicting the thrust augmentation levels that may be achieved. The speaker-driven jet provided a convenient source for the investigation because it is entirely unsteady (i.e., it has no mean velocity component) and because relevant parameters such as frequency, time-averaged thrust, and diameter are easily variable. The experimental setup will be described, as will the two main measurements techniques employed. These are thrust and digital particle imaging velocimetry of the driver. It will be shown that thrust augmentation values as high as 1.8 were obtained, that the diameter of the best ejector scaled with the dimensions of the emitted vortex, and that the so-called formation time serves as a useful dimensionless parameter by which to characterize the jet and predict performance.
Freckle Defect Formation near the Casting Interfaces of Directionally Solidified Superalloys
Hong, Jianping; Ma, Dexin; Wang, Jun; Wang, Fu; Sun, Baode; Dong, Anping; Li, Fei; Bührig-Polaczek, Andreas
2016-01-01
Freckle defects usually appear on the surface of castings and industrial ingots during the directional solidification process and most of them are located near the interface between the shell mold and superalloys. Ceramic cores create more interfaces in the directionally solidified (DS) and single crystal (SX) hollow turbine blades. In order to investigate the location of freckle occurrence in superalloys, superalloy CM247 LC was directionally solidified in an industrial-sized Bridgman furnace. Instead of ceramic cores, Alumina tubes were used inside of the casting specimens. It was found that freckles occur not only on the casting external surfaces, but also appear near the internal interfaces between the ceramic core and superalloys. Meanwhile, the size, initial position, and area of freckle were investigated in various diameters of the specimens. The initial position of the freckle chain reduces when the diameter of the rods increase. Freckle area follows a linear relationship in various diameters and the average freckle fraction is 1.1% of cross sectional area of casting specimens. The flow of liquid metal near the interfaces was stronger than that in the interdendritic region in the mushy zone, and explained why freckle tends to occur on the outer or inner surfaces of castings. This new phenomenon suggests that freckles are more likely to occur on the outer or inner surfaces of the hollow turbine blades. PMID:28774050
Freckle Defect Formation near the Casting Interfaces of Directionally Solidified Superalloys.
Hong, Jianping; Ma, Dexin; Wang, Jun; Wang, Fu; Sun, Baode; Dong, Anping; Li, Fei; Bührig-Polaczek, Andreas
2016-11-16
Freckle defects usually appear on the surface of castings and industrial ingots during the directional solidification process and most of them are located near the interface between the shell mold and superalloys. Ceramic cores create more interfaces in the directionally solidified (DS) and single crystal (SX) hollow turbine blades. In order to investigate the location of freckle occurrence in superalloys, superalloy CM247 LC was directionally solidified in an industrial-sized Bridgman furnace. Instead of ceramic cores, Alumina tubes were used inside of the casting specimens. It was found that freckles occur not only on the casting external surfaces, but also appear near the internal interfaces between the ceramic core and superalloys. Meanwhile, the size, initial position, and area of freckle were investigated in various diameters of the specimens. The initial position of the freckle chain reduces when the diameter of the rods increase. Freckle area follows a linear relationship in various diameters and the average freckle fraction is 1.1% of cross sectional area of casting specimens. The flow of liquid metal near the interfaces was stronger than that in the interdendritic region in the mushy zone, and explained why freckle tends to occur on the outer or inner surfaces of castings. This new phenomenon suggests that freckles are more likely to occur on the outer or inner surfaces of the hollow turbine blades.
John R. Brooks
2007-01-01
A technique for estimating stand average dominant height based solely on field inventory data is investigated. Using only 45.0919 percent of the largest trees per acre in the diameter distribution resulted in estimates of average dominant height that were within 4.3 feet of the actual value, when averaged over stands of very different structure and history. Cubic foot...
NASA Astrophysics Data System (ADS)
Ge, Xinlei; Setyan, Ari; Sun, Yele; Zhang, Qi
2012-10-01
Organic aerosols (OA) were studied in Fresno, California, in winter 2010 with an Aerodyne High Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS). OA dominated the submicron aerosol mass (average = 67%) with an average concentration of 7.9μg m-3 and a nominal formula of C1H1.59N0.014O0.27S0.00008, which corresponds to an average organic mass-to-carbon ratio of 1.50. Three primary OA (POA) factors and one oxygenated OA factor (OOA) representative of secondary OA (SOA) were identified via Positive Matrix Factorization of the high-resolution mass spectra. The three POA factors, which include a traffic-related hydrocarbon-like OA (HOA), a cooking OA (COA), and a biomass burning OA (BBOA) released from residential heating, accounted for an average 57% of the OA mass and up to 80% between 6 - 9 P.M., during which enhanced emissions from evening rush hour traffic, dinner cooking, and residential wood burning were exacerbated by low mixed layer height. The mass-based size distributions of the OA factors were estimated based on multilinear analysis of the size-resolved mass spectra of organics. Both HOA and BBOA peaked at ˜140 nm in vacuum aerodynamic diameter (Dva) while OOA peaked at an accumulation mode of ˜460 nm. COA exhibited a unique size distribution with two size modes centering at ˜200 nm and 450 nm respectively. This study highlights the leading roles played by anthropogenic POA emissions, primarily from traffic, cooking and residential heating, in aerosol pollution in Fresno in wintertime.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lindsay, P. E., E-mail: Patricia.Lindsay@rmp.uhn.on.ca; Granton, P. V.; Hoof, S. van
Purpose: To compare the dosimetric and geometric properties of a commercial x-ray based image-guided small animal irradiation system, installed at three institutions and to establish a complete and broadly accessible commissioning procedure. Methods: The system consists of a 225 kVp x-ray tube with fixed field size collimators ranging from 1 to 44 mm equivalent diameter. The x-ray tube is mounted opposite a flat-panel imaging detector, on a C-arm gantry with 360° coplanar rotation. Each institution performed a full commissioning of their system, including half-value layer, absolute dosimetry, relative dosimetry (profiles, percent depth dose, and relative output factors), and characterization ofmore » the system geometry and mechanical flex of the x-ray tube and detector. Dosimetric measurements were made using Farmer-type ionization chambers, small volume air and liquid ionization chambers, and radiochromic film. The results between the three institutions were compared. Results: At 225 kVp, with 0.3 mm Cu added filtration, the first half value layer ranged from 0.9 to 1.0 mm Cu. The dose-rate in-air for a 40 × 40 mm{sup 2} field size, at a source-to-axis distance of 30 cm, ranged from 3.5 to 3.9 Gy/min between the three institutions. For field sizes between 2.5 mm diameter and 40 × 40 mm{sup 2}, the differences between percent depth dose curves up to depths of 3.5 cm were between 1% and 4% on average, with the maximum difference being 7%. The profiles agreed very well for fields >5 mm diameter. The relative output factors differed by up to 6% for fields larger than 10 mm diameter, but differed by up to 49% for fields ≤5 mm diameter. The mechanical characteristics of the system (source-to-axis and source-to-detector distances) were consistent between all three institutions. There were substantial differences in the flex of each system. Conclusions: With the exception of the half-value layer, and mechanical properties, there were significant differences between the dosimetric and geometric properties of the three systems. This underscores the need for careful commissioning of each individual system for use in radiobiological experiments.« less
Estimation of lattice strain in nanocrystalline RuO2 by Williamson-Hall and size-strain plot methods
NASA Astrophysics Data System (ADS)
Sivakami, R.; Dhanuskodi, S.; Karvembu, R.
2016-01-01
RuO2 nanoparticles (RuO2 NPs) have been successfully synthesized by the hydrothermal method. Structure and the particle size have been determined by X-ray diffraction (XRD), scanning electron microscopy (SEM), atomic force microscopy (AFM) and transmission electron microscopy (TEM). UV-Vis spectra reveal that the optical band gap of RuO2 nanoparticles is red shifted from 3.95 to 3.55 eV. BET measurements show a high specific surface area (SSA) of 118-133 m2/g and pore diameter (10-25 nm) has been estimated by Barret-Joyner-Halenda (BJH) method. The crystallite size and lattice strain in the samples have been investigated by Williamson-Hall (W-H) analysis assuming uniform deformation, deformation stress and deformation energy density, and the size-strain plot method. All other relevant physical parameters including stress, strain and energy density have been calculated. The average crystallite size and the lattice strain evaluated from XRD measurements are in good agreement with the results of TEM.
Growth of ponderosa pine stands in relation to mountain pine beetle susceptibility
R. A. Obedzinski; J. M. Schmid; S. A. Mata; W. K. Olsen; R. R. Kessler
1999-01-01
Ten-year diameter and basal area growth were determined for partially cut stands at 4 locations. Average diameters in the partially cut plots generally increased by 1 inch or more, while average diameter in the uncut controls increased by 0.9 inches or less. Individual tree growth is discussed in relation to potential susceptibility to mountain pine beetle infestation...
The effect of the averaged structural and energetic features on the cohesive energy of nanocrystals
NASA Astrophysics Data System (ADS)
Ali Safaei
2010-03-01
The size dependency of the cohesive energy of nanocrystals is obtained in terms of their averaged structural and energetic properties, which are in direct proportion with their cohesive energies. The significance of the effect of the geometrical shape of nanoparticles on their thermal stability has been discussed. The model has been found to have good prediction for the case of Cu and Al nanoparticles, with sizes in the ranges of 1-22 nm and 2-22 nm, respectively. Defining a new parameter, named as the surface-to-volume energy-contribution ratio, the relative thermal stabilities of different nanoclusters and their different surface-crystalline faces are discussed and compared to the molecular dynamic (MD) simulation results of copper nanoclusters. Finally, based on the size dependency of the cohesive energy, a formula for the size-dependent diffusion coefficient has been presented which includes the structural and energetic effects. Using this formula, the faster-than-expected interdiffusion/alloying of Au(core)-Ag(shell) nanoparticles with the core-shell structure, the Au-core diameter of 20 nm and the Ag-shell thickness of 2.91 nm, has been discussed and the calculated diffusion coefficient has been found to be consistent with its corresponding experimental value.
Tallavaara, Pekka; Jokisaari, Jukka
2008-03-28
An alternative NMR method for determining nuclear shielding anisotropies in molecules is proposed. The method is quite simple, linear and particularly applicable for heteronuclear spin systems. In the technique, molecules of interest are dissolved in a thermotropic liquid crystal (LC) which is confined in a mesoporous material, such as controlled pore glass (CPG) used in this study. CPG materials consist of roughly spherical particles with a randomly oriented and connected pore network inside. LC Merck Phase 4 was confined in the pores of average diameter from 81 to 375 A and LC Merck ZLI 1115 in the pores of average diameter 81 A. In order to demonstrate the functionality of the method, the (13)C shielding anisotropy of (13)C-enriched methyl iodide, (13)CH(3)I, was determined as a function of temperature using one dimensional (13)C NMR spectroscopy. Methane gas, (13)CH(4), was used as an internal chemical shift reference. It appeared that methyl iodide molecules experience on average an isotropic environment in LCs inside the smallest pores within the whole temperature range studied, ranging from bulk solid to isotropic phase. In contrast, in the spaces in between the particles, whose diameter is approximately 150 microm, LCs behave as in the bulk. Consequently, isotropic values of the shielding tensor can be determined from spectra arising from molecules inside the pores at exactly the same temperature as the anisotropic ones from molecules outside the pores. Thus, for the first time in the solution state, shielding anisotropies can easily be determined as a function of temperature. The effects of pore size as well as of different LC media on the shielding anisotropy are examined and discussed.
Pujalté, Igor; Serventi, Alessandra; Noël, Alexandra; Dieme, Denis; Haddad, Sami; Bouchard, Michèle
2017-01-01
Nanoparticles (NPs) can be released in the air in work settings, but various factors influence the exposure of workers. Controlled inhalation experiments can thus be conducted in an attempt to reproduce real-life exposure conditions and assess inhalation toxicology. Methods exist to generate aerosols, but it remains difficult to obtain nano-sized and stable aerosols suitable for inhalation experiments. The goal of this work was to characterize aerosols of titanium dioxide (TiO2) NPs, generated using a novel inhalation system equipped with three types of generators—a wet collision jet nebulizer, a dry dust jet and an electrospray aerosolizer—with the aim of producing stable aerosols with a nano-diameter average (<100 nm) and monodispersed distribution for future rodent exposures and toxicological studies. Results showed the ability of the three generation systems to provide good and stable dispersions of NPs, applicable for acute (continuous up to 8 h) and repeated (21-day) exposures. In all cases, the generated aerosols were composed mainly of small aggregates/agglomerates (average diameter <100 nm) with the electrospray producing the finest (average diameter of 70–75 mm) and least concentrated aerosols (between 0.150 and 2.5 mg/m3). The dust jet was able to produce concentrations varying from 1.5 to 150 mg/m3, and hence, the most highly concentrated aerosols. The nebulizer collision jet aerosolizer was the most versatile generator, producing both low (0.5 mg/m3) and relatively high concentrations (30 mg/m3). The three optimized generators appeared suited for possible toxicological studies of inhaled NPs. PMID:29051446
Home range characteristics of Mexican Spotted Owls in the Rincon Mountains, Arizona
Willey, David W.; van Riper, Charles
2014-01-01
We studied a small isolated population of Mexican Spotted Owls (Strix occidentalis lucida) from 1996–1997 in the Rincon Mountains of Saguaro National Park, southeastern Arizona, USA. All mixed-conifer and pine-oak forest patches in the park were surveyed for Spotted Owls, and we located, captured, and radio-tagged 10 adult birds representing five mated pairs. Using radio-telemetry, we examined owl home range characteristics, roost habitat, and monitored reproduction within these five territories. Breeding season (Mar–Sep) home range size for 10 adult owls (95% adaptive kernel isopleths) averaged 267 ha (±207 SD), and varied widely among owls (range 34–652 ha). Mean home range size for owl pairs was 478 ha (±417 ha SD), and ranged from 70–1,160 ha. Owls that produced young used smaller home ranges than owls that had no young. Six habitat variables differed significantly between roost and random sites, including: percent canopy cover, number of trees, number of vegetation layers, average height of trees, average diameter of trees, and tree basal area. Radio-marked owls remained in their territories following small prescribed management fires within those territories, exhibiting no proximate effects to the presence of prescribed fire.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arbique, G; Anderson, J; Guild, J
Purpose: The National Lung Screening Trial mandated manual low dose CT technique factors, where up to a doubling of radiation output could be used over a regular to large patient size range. Recent guidance from the AAPM and ACR for lung cancer CT screening recommends radiation output adjustment for patient size either through AEC or a manual technique chart. This study evaluated the use of AEC for output control and dose reduction. Methods: The study was performed on a multidetector helical CT scanner (Aquillion ONE, Toshiba Medical) equipped with iterative reconstruction (ADIR-3D), AEC was adjusted with a standard deviation (SD)more » image quality noise index. The protocol SD parameter was incrementally increased to reduce patient population dose while image quality was evaluated by radiologist readers scoring the clinical utility of images on a Likert scale. Results: Plots of effective dose vs. body size (water cylinder diameter reported by the scanner) demonstrate monotonic increase in patient dose with increasing patient size. At the initial SD setting of 19 the average CTDIvol for a standard size patient was ∼ 2.0 mGy (1.2 mSv effective dose). This was reduced to ∼1.0 mGy (0.5 mSv) at an SD of 25 with no noticeable reduction in clinical utility of images as demonstrated by Likert scoring. Plots of effective patient diameter and BMI vs body size indicate that these metrics could also be used for manual technique charts. Conclusion: AEC offered consistent and reliable control of radiation output in this study. Dose for a standard size patient was reduced to one-third of the 3 mGy CTDIvol limit required for ACR accreditation of lung cancer CT screening. Gary Arbique: Research Grant, Toshiba America Medical Systems; Cecelia Brewington: Research Grant, Toshiba America Medical Systems; Di Zhang: Employee, Toshiba America Medical Systems.« less
Pajević, Tina; Glišić, Branislav
2017-05-01
Anthropological studies have reported that tooth size decreases in the context of diet changes. Some investigations have found a reverse trend in tooth size from the prehistoric to the modern times. The aims of this study were to analyze tooth size in skeletal samples from Mesolithic-Neolithic Age, Bronze Age, and Roman to Medieval times to determine sex differences and establish a temporal trend in tooth size in the aforementioned periods. Well-preserved permanent teeth were included in the investigation. The mesiodistal (MD) diameter of all teeth and buccolingual (BL) diameter of the molars were measured. Effects of sex and site were tested by one-way ANOVA, and the combined effect of these factors was analyzed by UNIANOVA. Sexual dimorphism was present in the BL diameters of all molars and MD diameters of the upper first and the lower third molar. The lower canine was the most dimorphic tooth in the anterior region. The MD diameter of most teeth showed no significant difference between the groups, (sample from: Mesolithic-Neolithic Age-group 1; Bronze Age-group 2; Roman times-group 3; Medieval times-group 4), whereas the BL diameters of the upper second and the lower first molar were the largest in the first group. Multiple comparisons revealed a decrease in the BL diameter of the upper second and the lower first molar from the first to the later groups. Lower canine MD diameter exhibited an increase in the fourth group compared to the second group. On the basis of the MD diameter, a temporal trend could not be observed for most of the teeth. The lower canine exhibited an increase in the MD diameter from the prehistoric to the Medieval times. Changes of BL diameter were more homogeneous, suggesting that the temporal trend of molar size decreased from the Mesolithic-Neolithic to Medieval times in Serbia. Copyright © 2017. Published by Elsevier Ltd.
Ihara, Tsutomu; Komori, Kimihiro; Yamamoto, Kiyohito; Kobayashi, Masayoshi; Banno, Hiroshi; Kodama, Akio
2013-02-01
Abdominal aortic aneurysm diameter is usually measured by the maximum minor-axis diameter on axial computed tomography (CT). However, this "traditional" diameter may underestimate the real size, as the aorta is not always straight and the aneurysm shape is sometimes in the form of an ellipse along the cross section. Therefore, we measured maximum major-axis diameters using a three-dimensional (3D) workstation and compared them with the traditional maximum minor-axis diameters measured using thin-slice axial CT. CT data of 141 AAA patients (with fusiform aneurysms) were stored in a 3D workstation. These thin-slice CT images were reviewed on the 3D workstation to obtain curved multiplanar reconstruction images (CPR images). Using the CPR images, we measured the maximum major-axis and minor-axis diameters on CPR and the angle of the aneurysms to the body axis. The mean traditional maximum minor-axis diameter was 51.2 ± 8.2 mm, whereas the mean maximum major-axis diameter on CPR was 54.7 ± 10.1 mm. Sixty eight patients had a mean aneurysm size of <50 mm when measured by the traditional minor-axis diameter. Among these patients, five (7.4%) had a major-axis diameter >55 mm on CPR. The measurement of the traditional maximum minor-axis diameter of aneurysms is useful in the case of most patients. However, the traditional maximum minor-axis diameter may underestimate the real aneurysmal diameter, particularly in patients with an ellipse-shaped aneurysm. The maximum major-axis diameter as measured using CPR images is effective for representing the real aneurysmal size. Copyright © 2013 Elsevier Inc. All rights reserved.
How is rainfall interception in urban area affected by meteorological parameters?
NASA Astrophysics Data System (ADS)
Zabret, Katarina; Rakovec, Jože; Mikoš, Matjaž; Šraj, Mojca
2017-04-01
Rainfall interception is part of the hydrological cycle. Precipitation, which hits vegetation, is retained on the leaves and branches, from which it eventually evaporates into the atmosphere (interception) or reaches the ground by dripping from the canopy, falling through the gaps (throughfall) and running down the stems (stemflow). The amount of rainfall reaching the ground depends on various meteorological and vegetation parameters. Rainfall, throughfall and stemflow have been measured in the city of Ljubljana, Slovenia since the beginning of 2014. Manual and automatic measurements are performed regularly under Betula pendula and Pinus nigra trees in urban area. In 2014, there were detected 178 rainfall events with total amount of 1672.1 mm. In average B. pendula intercepted 44% of rainfall and P. nigra intercepted 72% of rainfall. In 2015 we have detected 117 events with 1047.4 mm of rainfall, of which 37% was intercepted by B. pendula and 60% by P. nigra. The effect of various meteorological parameters on the rainfall interception was analysed in the study. The parameters included in the analysis were rainfall rate, rainfall duration, drop size distribution (average drop velocity and diameter), average wind speed, and average temperature. The results demonstrate decreasing rainfall interception with longer rainfall duration and higher rainfall intensity although the impact of the latter one is not statistically significant. In the case of very fast or very slow rainfall drops, the interception is higher than for the mean rain drop velocity values. In the case of P. nigra the impact of the rain drop diameter on interception is similar to the one of rain drop velocity while for B. pendula increasing of drop diameter also increases the interception. As expected, interception is higher for warmer events. This trend is more evident for P. nigra than for B. pendula. Furthermore, the amount of intercepted rainfall also increases with wind although it could be relatively high in case of very low wind speeds.
Schuldt, Bernhard; Leuschner, Christoph; Brock, Nicolai; Horna, Viviana
2013-02-01
It is generally assumed that the largest vessels are occurring in the roots and that vessel diameters and the related hydraulic conductance in the xylem are decreasing acropetally from roots to leaves. With this study in five tree species of a perhumid tropical rainforest in Sulawesi (Indonesia), we searched for patterns in hydraulic architecture and axial conductivity along the flow path from small-diameter roots through strong roots and the trunk to distal sun-canopy twigs. Wood density differed by not more than 10% across the different flow path positions in a species, and branch and stem wood density were closely related in three of the five species. Other than wood density, the wood anatomical and xylem hydraulic traits varied in dependence on the position along the flow path, but were unrelated to wood density within a tree. In contrast to reports from conifers and certain dicotyledonous species, we found a hump-shaped variation in vessel diameter and sapwood area--specific conductivity along the flow path in all five species with a maximum in the trunk and strong roots and minima in both small roots and twigs; the vessel size depended on the diameter of the organ. This pattern might be an adaptation to the perhumid climate with a low risk of hydraulic failure. Despite a similar mean vessel diameter in small roots and twigs, the two distal organs, hydraulically weighted mean vessel diameters were on average 30% larger in small roots, resulting in ∼ 85% higher empirical and theoretical specific conductivities. Relative vessel lumen area in percent of sapwood area decreased linearly by 70% from roots to twigs, reflecting the increase in sclerenchymatic tissue and tracheids in acropetal direction in the xylem. Vessel size was more closely related to the organ diameter than to the distance along the root-to-shoot flow path. We conclude that (i) the five co-occurring tree species show convergent patterns in their hydraulic architecture despite different growth strategies, and (ii) the paradigm assuming continuous acropetal vessel tapering and decrease in specific conductance from fine roots towards distal twigs needs reconsideration.
7 CFR 51.2952 - Size specifications.
Code of Federal Regulations, 2012 CFR
2012-01-01
... a round opening 96/64 inches in diameter; (b) Jumbo size. Jumbo size means walnuts of which not over 12 percent, by count, pass through a round opening 80/64 inches in diameter; (c) Large size. Large size means walnuts of which not over 12 percent, by count, pass through a round opening 77/64 inches in...
Molteni, Matteo; Magatti, Davide; Cardinali, Barbara; Rocco, Mattia; Ferri, Fabio
2013-01-01
The average pore size ξ0 of filamentous networks assembled from biological macromolecules is one of the most important physical parameters affecting their biological functions. Modern optical methods, such as confocal microscopy, can noninvasively image such networks, but extracting a quantitative estimate of ξ0 is a nontrivial task. We present here a fast and simple method based on a two-dimensional bubble approach, which works by analyzing one by one the (thresholded) images of a series of three-dimensional thin data stacks. No skeletonization or reconstruction of the full geometry of the entire network is required. The method was validated by using many isotropic in silico generated networks of different structures, morphologies, and concentrations. For each type of network, the method provides accurate estimates (a few percent) of the average and the standard deviation of the three-dimensional distribution of the pore sizes, defined as the diameters of the largest spheres that can be fit into the pore zones of the entire gel volume. When applied to the analysis of real confocal microscopy images taken on fibrin gels, the method provides an estimate of ξ0 consistent with results from elastic light scattering data. PMID:23473499
Hollow porous-wall glass microspheres for hydrogen storage
Heung, Leung K.; Schumacher, Ray F.; Wicks, George G.
2010-02-23
A porous wall hollow glass microsphere is provided having a diameter range of between 1 to 200 microns, a density of between 1.0 to 2.0 gm/cc, a porous-wall structure having wall openings defining an average pore size of between 10 to 1000 angstroms, and which contains therein a hydrogen storage material. The porous-wall structure facilitates the introduction of a hydrogen storage material into the interior of the porous wall hollow glass microsphere. In this manner, the resulting hollow glass microsphere can provide a membrane for the selective transport of hydrogen through the porous walls of the microsphere, the small pore size preventing gaseous or liquid contaminants from entering the interior of the hollow glass microsphere.
Photodynamic therapy in prostate cancer: optical dosimetry and response of normal tissue
NASA Astrophysics Data System (ADS)
Chen, Qun; Shetty, Sugandh D.; Heads, Larry; Bolin, Frank; Wilson, Brian C.; Patterson, Michael S.; Sirls, Larry T., II; Schultz, Daniel; Cerny, Joseph C.; Hetzel, Fred W.
1993-06-01
The present study explores the possibility of utilizing photodynamic therapy (PDT) in treating localized prostate carcinoma. Optical properties of ex vivo human prostatectomy specimens, and in vivo and ex vivo dog prostate glands were studied. The size of the PDT induced lesion in dog prostate was pathologically evaluated as a biological endpoint. The data indicate that the human normal and carcinoma prostate tissues have similar optical properties. The average effective attenuation depth is less in vivo than that of ex vivo. The PDT treatment generated a lesion size of up to 16 mm in diameter. The data suggest that PDT is a promising modality in prostate cancer treatment. Multiple fiber system may be required for clinical treatment.
Tomoda, Keishiro; Ohkoshi, Takumi; Kawai, Yusaku; Nishiwaki, Motoko; Nakajima, Takehisa; Makino, Kimiko
2008-02-15
To overcome the disadvantages both of microparticles and nanoparticles for inhalation, we have prepared nanocomposite particles as drug carriers targeting lungs. The nanocomposite particles having sizes about 2.5 microm composed of sugar and drug-loaded PLGA nanoparticles can reach deep in the lungs, and they are decomposed into drug-loaded PLGA nanoparticles in the alveoli. Sugar was used as a binder of PLGA nanoparticles to be nanocomposite particles and is soluble in alveolar lining fluid. The primary nanoparticles containing bioactive materials were prepared by using a probe sonicator. And then they were spray dried with carrier materials, such as trehalose and lactose. The effects of inlet temperature of spray dryer were studied between 60 and 120 degrees C and the kind of sugars upon properties of nanocomposite particles. When the inlet temperatures were 80 and 90 degrees C, nanocomposite particles with average diameters of about 2.5 microm are obtained and they are decomposed into primary nanoparticles in water, in both sugars are used as a binder. But, those prepared above 100 degrees C are not decomposed into nanoparticles in water, while the average diameter was almost 2.5 microm. On the other hand, nanocomposite particles prepared at lower inlet temperatures have larger sizes but better redispersion efficiency in water. By the measurements of aerodynamic diameters of the nanocomposite particles prepared with trehalose at 70, 80, and 90 degrees C, it was shown that the particles prepared at 80 degrees C have the highest fine particle fraction (FPF) value and the particles are suitable for pulmonary delivery of bioactive materials deep in the lungs. Meanwhile the case with lactose, the particles prepared at 90 degrees C have near the best FPF value but they have many particles larger than 11 microm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nathanael, A. Joseph; Department of Nanomaterials Engineering, Chungnam National University, Daejeon, 305-764; Mangalaraj, D., E-mail: dmraj800@yahoo.com
In this study, undoped and yttrium (Y) doped nanocrystalline hydroxyapatite crystals were synthesized by the hydrothermal method at 180 Degree-Sign C for 24 h. Highly ordered and oriented hydroxyapatite (HAp) nanorods were prepared by yttrium doping and their nanostructure and physical properties were compared with those of undoped HAp rods. FESEM images showed that the doping with Y ions reduced the diameter (from 25 nm to 15 nm) and increased the length (from 95 nm to 115 nm) of the synthesized rods. The aspect ratio of the undoped and Y-doped nanorods were calculated to be 4.303 (SD = 0.0959) andmore » 7.61 (SD = 0.0355), respectively. Specific surface area (SSA) analysis showed that SSA also increased from 66.74 m{sup 2}/g to 68.57 m{sup 2}/g with the addition of yttrium. Y-doped HAp nanorod reinforced HMWPE composites displayed the better mechanical performance than those reinforced with pure HAp nanorods. The possible strengthening of nanorods and the increase of SSA due to the reduction in the size of nanorods in the presence of yttrium may have contributed to the strengthening of Y-doped HAp/HMWPE composites. - Graphical Abstract: Highly ordered and oriented yttrium doped hydroxyapatite (HAp) nanorods were prepared by hydrothermal method. For undoped HAp the average length of the nanorod is 95 nm with mean diameter of 24 nm and for a Y doped nanorod the average length is {approx} 115 nm and the mean diameter is 15 nm. Mechanical analysis was carried out by polymer/nanoparticle composite method. Highlights: Black-Right-Pointing-Pointer Yttrium doped hydroxyapatite nanorods were prepared by hydrothermal method. Black-Right-Pointing-Pointer The nanorods have highly uniform size distribution. Black-Right-Pointing-Pointer Yttrium substitution and nanostructure formation was confirmed by careful analysis. Black-Right-Pointing-Pointer Mechanical strength was analyzed by polymer nanoparticle reinforcement method.« less
NASA Astrophysics Data System (ADS)
Kshirasagar, Krushna J.; Markad, Uddhav S.; Saha, Abhijit; Sharma, Kiran Kumar K.; Sharma, Geeta K.
2017-02-01
Palladium nanoparticles doped polyaniline (Pd-PANI) nanocomposite (NCs) is synthesized in surfactant based liquid crystalline mesophase by chemical oxidation followed by radiolysis. The confinement of the liquid crystalline mesophase facilitates polymerization of aniline monomers and their 1D growth into polyaniline (PANI) nanowires by using ammonium persulfate. The PANI nanowires have an average diameter of 30-40 nm. The in situ radiolytic reduction of palladium ions ensures uniform size distribution of the palladium (Pd) nanoparticles on the surface of the PANI nanowires. The synthesized Pd-PANI nanocomposites show wire like structures of PANI (diameter ~30-40 nm) on which Pd nanoparticles of the size 10 nm are decorated. The identical average diameter of the PANI nanowires before and post gamma irradiation suggest high stability of the PANI nanowires in liquid crystalline mesophase. Surface characterization of the NCs were carried out using BET and XPS. The catalytic activity of Pd-PANI NCs are investigated in the reduction of methylene blue (MB) and 4-nitro phenol (4-NP) by sodium borohydride (NaBH4). The kinetics of the Pd-PANI NCs catalysed reactions are analysed using the Langmuir-Hinshelwood model. The apparent rate constant (k app) for the MB and 4-NP reduction reactions is 29 × 10-3 s-1 and 20 × 10-3 s-1 respectively with an actual Pd catalyst loading of 2.665 × 10-4 ppm. Further, the recyclability of the Pd-PANI NCs catalyst in both the reduction reactions shows the stability of the catalyst up to four reaction cycles tested in this investigation and the multifunctional nature of the catalyst. The study provides a new approach for the directional synthesis of conducting polymer-metal nanocomposites and their possible application as a nanocatalyst in environmental remediation.
Dimensions of stabident intraosseous perforators and needles.
Ramlee, R A; Whitworth, J
2001-09-01
Problems can be encountered inserting intraosseous injection needles through perforation sites. This in vitro study examined the variability and size compatibility of Stabident intraosseous injection components. The diameters of 40 needles and perforators from a single Stabident kit were measured in triplicate with a toolmakers microscope. One-way ANOVA revealed that mean needle diameter (0.411 mm) was significantly narrower than mean perforator diameter (0.427 mm) (p < 0.001). A frequency distribution plot revealed that needle diameter followed a normal distribution, indicating tight quality control during manufacture. The diameter of perforators was haphazardly distributed, with a clustering of 15% at the lower limit of the size range. However on no occasion was the diameter of a perforator smaller than that of an injection needle. We conclude that components of the Stabident intraosseous anaesthetic system are size-compatible, but there is greater and more haphazard variability in the diameter of perforators than injection needles.
NASA Astrophysics Data System (ADS)
Ragettli, Martina S.; Corradi, Elisabetta; Braun-Fahrländer, Charlotte; Schindler, Christian; de Nazelle, Audrey; Jerrett, Michael; Ducret-Stich, Regina E.; Künzli, Nino; Phuleria, Harish C.
2013-10-01
A better understanding of ultrafine particle (UFP) exposure in different urban transport microenvironments is important for epidemiological exposure assessments and for policy making. Three sub-studies were performed to characterize personal exposure to UFP concentration and average particle size distribution diameters in frequently traveled commuter microenvironments in the city of Basel, Switzerland. First, the spatial variation of sidewalk UFP exposures within urban areas and transport-specific microenvironments was explored. Second, exposure to UFP concentration and average particle size were quantified for five modes of transportation (walking, bicycle, bus, tram, car) during different times of the day and week, along the same route. Finally, the contribution of bicycle commuting along two different routes (along main roads, away from main roads) to total daily exposures was assessed by 24-h personal measurements. In general, smaller average particle sizes and higher UFP levels were measured at places and for travel modes in close proximity to traffic. Average trip UFP concentrations were higher in car (31,784 particles cm-³) and on bicycle (22,660 particles cm-³) compared to walking (19,481 particles cm-³) and public transportation (14,055-18,818 particles cm-³). Concentrations were highest for all travel modes during weekday morning rush hours, compared to other time periods. UFP concentration was lowest in bus, regardless of time period. Bicycle travel along main streets between home and work place (24 min on average) contributed 21% and 5% to total daily UFP exposure in winter and summer, respectively. Contribution of bicycle commutes to total daily UFP exposure could be reduced by half if main roads are avoided. Our results show the importance of considering commuter behavior and route choice in exposure assessment studies.
Chaotic Mountain Blocks in Pluto’s Sputnik Planitia
NASA Astrophysics Data System (ADS)
Singer, Kelsi N.; Knight, Katherine I.; Stern, S. Alan; Olkin, Catherine; Grundy, William M.; McKinnon, William B.; Moore, Jeffrey M.; Schenk, Paul M.; Spencer, John R.; Weaver, Harold A.; Young, Leslie; Ennico, Kimberly; New Horizons Geology, Geophysics and Imaging Science Theme Team, The New Horizons Surface Composition Science Theme Team
2017-10-01
One of the first high-resolution Pluto images returned by New Horizons displayed a collection of tall, jagged peaks rising out of the large nitrogen ice sheet informally known as Sputnik Planitia (SP). This mountain range was later revealed to be one of several along the western edge of SP. The mountains are several hundred broken-up blocks of Pluto’s primarily water ice lithosphere and some retain surface terrains similar to the nearby intact crust surrounding SP. Water ice with some fractures or porosity is likely >5% less dense than solid N2 ice at Pluto’s temperatures. Thus it is possible the blocks are, or were, floating icebergs or at least partially suspended to the point that some blocks appear to be tilted as if they have faltered (Moore et al., 2016, Science, 351, 1284-1293).We analyze four mountain ranges on the western edge of SP and compare to chaotic terrains on Europa and Mars. The blocks on Pluto have angular planforms but we characterize their size using block surface area converted to an equivalent circular diameter. Topography was used to define block extents. The blocks range in size from 3-30 km in diameter, with a mode of ~8-10 km. Blocks range from 0.2-3.8 km in height, and block height generally increases with block diameter. One or more dark layers can be identified in a few scarp faces, and are at a similar depth to each other and to layers seen in fault and crater walls elsewhere on Pluto. A large N-S trending fault system runs tangential to SP and may be the source of crustal disruption on the western side.On Europa and Mars block sizes vary greatly between different chaos regions, but Conamara Chaos has an average block size of ~5 km in diameter, smaller than that typically seen on Pluto. Also the blocks often transition into fractured terrain still connected to the surround lithosphere at the periphery of the chaos regions. The source regions for the blocks are more obvious on Europa and Mars. Additionally the block heights on Europa and Mars generally do not increase with block size. Thus, the main mechanism of crustal breakup is likely different between these bodies.
Nanoparticle diffusion in, and microrheology of, the bovine vitreous ex vivo
Xu, Qingguo; Boylan, Nicholas J.; Suk, Jung Soo; Wang, Ying-Ying; Nance, Elizabeth; Yang, Jeh-Chang; McDonnell, Peter; Cone, Richard; Duh, Elia J.; Hanes, Justin
2013-01-01
Intravitreal injection of biodegradable nanoparticles (NP) holds promise for gene therapy and drug delivery to the back of the eye. In some cases, including gene therapy, NP need to diffuse rapidly from the site of injection in order to reach targeted cell types in the back of the eye, whereas in other cases it may be preferred for the particles to remain at the injection site and slowly release drugs that may then diffuse to the site of action. We studied the movements of polystyrene (PS) nanoparticles of various sizes and surface chemistries in fresh bovine vitreous. PS NP as large as 510 nm rapidly penetrated the vitreous gel when coated with polyethylene glycol (PEG), whereas the movements of NP 1190 nm in diameter or larger were highly restricted regardless of surface chemistry owing to steric obstruction. PS NP coated with primary amine groups (–NH2) possessed positively charged surfaces at the pH of bovine vitreous (pH = 7.2), and were immobilized within the vitreous gel. In comparison, PS NP coated with –COOH (possessing negatively charged surfaces) in the size range of 100–200 nm and at particle concentrations below 0.0025% (w/v) readily diffused through the vitreous meshwork; at higher concentrations (~0.1% w/v), these nanoparticles aggregated within vitreous. Based on the mobility of different sized PS-PEG NP, we estimated the average mesh size of fresh bovine vitreous to be ~550 ± 50 nm. The bovine vitreous behaved as an impermeable elastic barrier to objects sized 1190 nm and larger, but as a highly permeable viscoelastic liquid to non-adhesive objects smaller than 510 nm in diameter. Guided by these studies, we next sought to examine the transport of drug- and DNA-loaded nanoparticles in bovine vitreous. Biodegradable NP with diameter of 227 nm, composed of a poly(lactic-co-glycolic acid) (PLGA)-based core coated with poly(vinyl alcohol) rapidly penetrated vitreous. Rod-shaped, highly-compacted CK30PEG10k/DNA with PEG coating (neutral surface charge; diameter ~60 nm) diffused rapidly within vitreous. These findings will help guide the development of nanoparticle-based therapeutics for the treatment of vision-threatening ocular diseases. PMID:23369761
In situ measurements of plasma properties during gas-condensation of Cu nanoparticles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koten, M. A., E-mail: mark.koten@gmail.com; Shield, J. E.; Voeller, S. A.
2016-03-21
Since the mean, standard deviation, and modality of nanoparticle size distributions can vary greatly between similar input conditions (e.g., power and gas flow rate), plasma diagnostics were carried out in situ using a double-sided, planar Langmuir probe to determine the effect the plasma has on the heating of clusters and their final size distributions. The formation of Cu nanoparticles was analyzed using cluster-plasma physics, which relates the processes of condensation and evaporation to internal plasma properties (e.g., electron temperature and density). Monitoring these plasma properties while depositing Cu nanoparticles with different size distributions revealed a negative correlation between average particlemore » size and electron temperature. Furthermore, the modality of the size distributions also correlated with the modality of the electron energy distributions. It was found that the maximum cluster temperature reached during plasma heating and the material's evaporation point regulates the growth process inside the plasma. In the case of Cu, size distributions with average sizes of 8.2, 17.3, and 24.9 nm in diameter were monitored with the Langmuir probe, and from the measurements made, the cluster temperatures for each deposition were calculated to be 1028, 1009, and 863 K. These values are then compared with the onset evaporation temperature of particles of this size, which was estimated to be 1059, 1068, and 1071 K. Thus, when the cluster temperature is too close to the evaporation temperature, less particle growth occurs, resulting in the formation of smaller particles.« less
[Malignant nonepithelial tumors of the lung].
Trakhtenberg, A Kh; Biriukov, Iu V; Frank, G A; Kunitsyn, A G; Grigor'eva, S P; Aĭtakov, Z N; Korenev, S V; Efimova, O Iu; Vial'tsev, N V
1990-01-01
The main peculiarities of the clinical course of lung sarcoma were determined from representative material of 134 patients. The main features differentiating malignant nonepithelial tumors from carcinoma of the lung are: younger age (average age 45.5 years), predominantly peripheral clinico-anatomical form (82.8%), and prevalent hematogenic metastasis. Five-year survival in the whole group of patients after surgical treatment was 54%. The size and histological form of the tumor are the main factors of prognosis. The degree of differentiation acquires prognostic significance in tumors measuring more than 3 cm in diameter.
Material with core-shell structure
Luhrs, Claudia [Rio Rancho, NM; Richard, Monique N [Ann Arbor, MI; Dehne, Aaron [Maumee, OH; Phillips, Jonathan [Rio Rancho, NM; Stamm, Kimber L [Ann Arbor, MI; Fanson, Paul T [Brighton, MI
2011-11-15
Disclosed is a material having a composite particle, the composite particle including an outer shell and a core. The core is made from a lithium alloying material and the outer shell has an inner volume that is greater in size than the core of the lithium alloying material. In some instances, the outer mean diameter of the outer shell is less than 500 nanometers and the core occupies between 5 and 99% of the inner volume. In addition, the outer shell can have an average wall thickness of less than 100 nanometers.
Lee, Ki-Chang; Choo, Hun-Seung
2014-11-01
Narrowly dispersed poly(BMA-co-MMA) and PBMA latices with particle diameters ranging within 216-435 nm were synthesized successfully by surfactant-free emulsion polymerization with KPS and AIBA. The average particle diameter and particle size distribution, average molecular weight and its distribution, glass transition temperature, reflectance spectra in visible wavelength, and refractive indices for the respective poly(BMA-co-MMA) latices and their photonic crystals were systematically investigated in terms of BMA/MMA ratio, BMA content, polymerization temperature, and DVB effect. The rate of polymerization increased with increasing MMA concentration in BMA/MMA ratio. The particle diameter increased with BMA concentration in BMA/MMA ratio. The molecular weight increased with BMA concentration in BMA/MMA ratio and monomer concentration. The drying of the latices offered self-assembled shiny colloidal crystal films showing the characteristic structural colors in visible wavelength. All the poly(BMA-co-MMA) latices prepared in the study were fallen within the range of photonic grade microspheres. The reflectance measurement on the colloidal photonic crystals having different particle diameters clearly exhibited narrow stopbands. The reflection maxima (λ(max)) measured in this study were well close to the λ(max) calculated, derived from the Bragg's equation. The refractive indices of poly(BMA-co-MMA) photonic crystals were found to be almost same as the theoretical values and increased proportionally from 1.50 to 1.57 with BMA content in BMA/MMA ratios. It was, thus, found that the optical reflectance properties of the poly(BMA-co-MMA) colloidal photonic crystals can be controlled easily by adjusting the reaction conditions and BMA/MMA ratio in soap-free emulsion copolymerization of BMA and MMA.
Particle size analysis of some water/oil/water multiple emulsions.
Ursica, L; Tita, D; Palici, I; Tita, B; Vlaia, V
2005-04-29
Particle size analysis gives useful information about the structure and stability of multiple emulsions, which are important characteristics of these systems. It also enables the observation of the growth process of particles dispersed in multiple emulsions, accordingly, the evolution of their dimension in time. The size of multiple particles in the seven water/oil/water (W/O/W) emulsions was determined by measuring the particles size observed during the microscopic examination. In order to describe the distribution of the size of multiple particles, the value of two parameters that define the particle size was calculated: the arithmetical mean diameter and the median diameter. The results of the particle size analysis in the seven multiple emulsions W/O/W studied are presented as histograms of the distribution density immediately, 1 and 3 months after the preparation of each emulsion, as well as by establishing the mean and the median diameter of particles. The comparative study of the distribution histograms and of the mean and median diameters of W/O/W multiple particles indicates that the prepared emulsions are fine and very fine dispersions, stable, and presenting a growth of the abovementioned diameters during the study.
Zhang, Hualin; Gopalakrishnan, Mahesh; Lee, Plato; Kang, Zhuang; Sathiaseelan, Vythialingam
2016-09-08
The purpose of this study was to evaluate the dosimetric impact of cylinder size in high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT). Sample plans of HDR VCBT in a list of cylinders ranging from 2.5 to 4 cm in diameter at 0.5 cm incre-ment were created and analyzed. The doses were prescribed either at the 0.5cm depth with 5.5 Gy for 4 fractions or at the cylinder surface with 8.8 Gy for 4 frac-tions, in various treatment lengths. A 0.5 cm shell volume called PTV_Eval was contoured for each plan and served as the target volume for dosimetric evaluation. The cumulative and differential dose volume histograms (c-DVH and d-DVH), mean doses (D-mean) and the doses covering 90% (D90), 10% (D10), and 5% (D5) of PTV_Eval were calculated. In the 0.5 cm depth regimen, the DVH curves were found to have shifted toward the lower dose zone when a larger cylinder was used, but in the surface regimen the DVH curves shifted toward the higher dose zone as the cylinder size increased. The D-means of the both regimens were between 6.9 and 7.8 Gy and dependent on the cylinder size but independent of the treatment length. A 0.5 cm variation of diameter could result in a 4% change of D-mean. Average D90s were 5.7 (ranging from 5.6 to 5.8 Gy) and 6.1 Gy (from 5.7 to 6.4 Gy), respectively, for the 0.5 cm and surface regimens. Average D10 and D5 were 9.2 and 11 Gy, respectively, for the 0.5 cm depth regimen, and 8.9 and 9.7 Gy, respectively, for the surface regimen. D-mean, D90, D10, and D5 for other prescription doses could be calculated from the lookup tables of this study. Results indicated that the cylinder size has moderate dosimetric impact, and that both regimens are comparable in dosimetric quality. © 2016 The Authors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deng, Jingheng; Wen, Xianghua, E-mail: xhwen@tsinghua.edu.cn; Wang, Qinian
Graphical abstract: After purification, the multi-wall carbon nanotubes (MWCNTs) act as seeds for Fe{sub 3}O{sub 4} nanoparticles heterogeneous nucleation. The Fe{sub 3}O{sub 4} nanoparticles with diameter range of 4.2–10.0 nm synthesized in situ on the MWCNTs under solvothermal condition. The formed nano Fe{sub 3}O{sub 4}-MWCNTs decolorized the Acid Orange II effectively via Fenton-like reaction. Highlights: ► The amount of water tunes size and size distribution of the Fe{sub 3}O{sub 4} nanoparticles (FNs). ► FNs are homogeneously coated on the multi-walled carbon nanotubes (MWCNTs). ► FNs have diameters in the range of 4.2–10.0 nm, average grain size of 7.4 nm. ►more » Fe{sub 3}O{sub 4}-MWCNTs are used as a Fenton-like catalyst to decompose Acid Orange II. ► Fe{sub 3}O{sub 4}-MWCNTs displayed a higher activity than nanometer-size Fe{sub 3}O{sub 4}. -- Abstract: Fe{sub 3}O{sub 4}-multi-walled carbon nanotubes (Fe{sub 3}O{sub 4}-MWCNTs) hybrid materials were synthesized by a solvothermal process using acid treated MWCNTs and iron acetylacetonate in a mixed solution of ethylene glycol and ultrapure water. The materials were characterized using X-ray powder diffraction, scanning and transmission electron microscopy, X-ray photoelectron spectroscopy, and vibrating sample magnetometry. The results showed that a small amount of water in the synthesis system played a role in controlling crystal phase formation, size of Fe{sub 3}O{sub 4}, and the homogeneous distribution of the Fe{sub 3}O{sub 4} nanoparticles deposited on the MWCNTs. The Fe{sub 3}O{sub 4} nanoparticles had diameters in the range of 4.2–10.0 nm. They displayed good superparamagnetism at room temperature and their magnetization was influenced by the reaction conditions. They were used as a Fenton-like catalyst to decompose Acid Orange II and displayed a higher activity than nanometer-size Fe{sub 3}O{sub 4}.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morales, Johnny E., E-mail: johnny.morales@lh.org.
Purpose: An experimental extrapolation technique is presented, which can be used to determine the relative output factors for very small x-ray fields using the Gafchromic EBT3 film. Methods: Relative output factors were measured for the Brainlab SRS cones ranging in diameters from 4 to 30 mm{sup 2} on a Novalis Trilogy linear accelerator with 6 MV SRS x-rays. The relative output factor was determined from an experimental reducing circular region of interest (ROI) extrapolation technique developed to remove the effects of volume averaging. This was achieved by scanning the EBT3 film measurements with a high scanning resolution of 1200 dpi.more » From the high resolution scans, the size of the circular regions of interest was varied to produce a plot of relative output factors versus area of analysis. The plot was then extrapolated to zero to determine the relative output factor corresponding to zero volume. Results: Results have shown that for a 4 mm field size, the extrapolated relative output factor was measured as a value of 0.651 ± 0.018 as compared to 0.639 ± 0.019 and 0.633 ± 0.021 for 0.5 and 1.0 mm diameter of analysis values, respectively. This showed a change in the relative output factors of 1.8% and 2.8% at these comparative regions of interest sizes. In comparison, the 25 mm cone had negligible differences in the measured output factor between zero extrapolation, 0.5 and 1.0 mm diameter ROIs, respectively. Conclusions: This work shows that for very small fields such as 4.0 mm cone sizes, a measureable difference can be seen in the relative output factor based on the circular ROI and the size of the area of analysis using radiochromic film dosimetry. The authors recommend to scan the Gafchromic EBT3 film at a resolution of 1200 dpi for cone sizes less than 7.5 mm and to utilize an extrapolation technique for the output factor measurements of very small field dosimetry.« less
Jeffrey H. Gove
2003-01-01
This note seeks to extend the utility of size-biased distribution theory as applied to forestry through two relationships regarding the quadratic mean stand diameter. First, the quadratic mean stand diameter's relationship to the harmonic mean basal area for horizontal point sampling, which has been known algebraically from early on, is proved under size-biased...
NASA Astrophysics Data System (ADS)
Marques, J. F.; Lima, A. B.; Araújo, N. A. M.; Cadilhe, A.
2012-06-01
We performed extensive Monte Carlo simulations of the irreversible adsorption of polydispersed disks inside the cells of a patterned substrate. The model captures relevant features of the irreversible adsorption of spherical colloidal particles on patterned substrates. The pattern consists of (equal) square cells, where adsorption can take place, centered at the vertices of a square lattice. Two independent, dimensionless parameters are required to control the geometry of the pattern, namely, the cell size and cell-cell distance, measured in terms of the average particle diameter. However, to describe the phase diagram, two additional dimensionless parameters, i.e., the minimum and maximum particle radii, are also required. We find that the transition between any two adjacent regions of the phase diagram solely depends on the largest and smallest particle sizes, but not on the shape of the distribution function of the radii. We consider size dispersions up to 20% of the average radius using a physically motivated, truncated, Gaussian-size distribution, and focus on the regime where adsorbing particles do not interact with those previously adsorbed on neighboring cells to characterize the jammed state structure. The study generalizes previous exact relations on monodisperse particles to account for size dispersion. Due to the presence of the pattern, the coverage shows a nonmonotonic dependence on the cell size. The pattern also affects the radius of adsorbed particles, where one observes preferential adsorption of smaller radii, particularly at high polydispersity.
Menapace, I; Masad, E; Bhasin, A
2016-04-01
This paper offers important insights on the development of the microstructure in asphalt binders as a function of the treatment temperature. Different treatment temperatures are useful to understand how dispersed domains form when different driving energies for the mobility of molecular species are provided. Small and flat dispersed domains, with average diameter between 0.02 and 0.70 μm, were detected on the surface of two binders at room temperature, and these domains were observed to grow with an increase in treatment temperature (up to over 2 μm). Bee-like structures started to appear after treatment at or above 100°C. Moreover, the effect of the binder thickness on its microstructure at room temperature and at higher treatment temperatures was investigated and is discussed in this paper. At room temperature, the average size of the dispersed domains increased as the binder thickness decreased. A hypothesis that conciliates current theories on the origin and development of dispersed domains is proposed. Small dispersed domains (average diameter around 0.02 μm) are present in the bulk of the binder, whereas larger domains and bee-like structures develop on the surface, following heat treatment or mechanical disturbance that reduces the film thickness. Molecular mobility and association are the key factors in the development of binder microstructure. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.
Ytre-Hauge, Sigmund; Husby, Jenny A; Magnussen, Inger J; Werner, Henrica M J; Salvesen, Øyvind O; Bjørge, Line; Trovik, Jone; Stefansson, Ingunn M; Salvesen, Helga B; Haldorsen, Ingfrid S
2015-03-01
The aim of this study was to explore the relation between preoperative tumor size based on magnetic resonance imaging (MRI) and the surgical pathologic staging parameters (deep myometrial invasion, cervical stroma invasion, and metastatic lymph nodes) and to assess the prognostic impact of tumor size in endometrial carcinomas. Interobserver variability for the different tumor size measurements was also assessed. Preoperative pelvic MRI of 212 patients with histologically confirmed endometrial carcinomas was read independently by 3 radiologists. Maximum tumor diameters were measured in 3 orthogonal planes (anteroposterior, transverse, and craniocaudal planes [CC]), and tumor volumes were estimated. Tumor size was analyzed in relation to surgical staging results and patient survival. The multivariate analyses were adjusted for preoperative risk status based on endometrial biopsy. Intraclass correlation coefficients and receiver operating characteristics curves for the different tumor measurements were also calculated. Anteroposterior tumor diameter independently predicted deep myometrial invasion (P < 0.001), whereas CC tumor diameter tended to independently predict lymph node metastases (P = 0.06). Based on receiver operating characteristic curves, the following tumor size cutoff values were identified: anteroposterior diameter greater than 2 cm predicted deep myometrial invasion (unadjusted odds ratio [OR], 12.4; P < 0.001; adjusted OR, 6.7; P < 0.001) and CC diameter greater than 4 cm predicted lymph node metastases (unadjusted OR, 6.2; P < 0.001; adjusted OR, 4.9; P = 0.009). Large tumor size was associated with reduced progression/recurrence-free survival (P ≤ 0.005 for all size parameters), and CC diameter had an independent impact on survival (adjusted hazards ratio, 1.04; P = 0.009). The interobserver variability for the different size measurements was very low (intraclass correlation coefficient, 0.78-0.85). Anteroposterior tumor diameter greater than 2 cm predicts deep myometrial invasion, and CC tumor diameter greater than 4 cm predicts lymph node metastases. Tumor size is a strong prognostic factor in endometrial carcinomas. Preoperative tumor measurements based on MRI may potentially improve preoperative risk stratification models and thus enable better tailored surgical treatment in endometrial cancer.
Zhang, Yakun; Li, Xiang; Segars, W. Paul; Samei, Ehsan
2014-01-01
Purpose: Given the radiation concerns inherent to the x-ray modalities, accurately estimating the radiation doses that patients receive during different imaging modalities is crucial. This study estimated organ doses, effective doses, and risk indices for the three clinical chest x-ray imaging techniques (chest radiography, tomosynthesis, and CT) using 59 anatomically variable voxelized phantoms and Monte Carlo simulation methods. Methods: A total of 59 computational anthropomorphic male and female extended cardiac-torso (XCAT) adult phantoms were used in this study. Organ doses and effective doses were estimated for a clinical radiography system with the capability of conducting chest radiography and tomosynthesis (Definium 8000, VolumeRAD, GE Healthcare) and a clinical CT system (LightSpeed VCT, GE Healthcare). A Monte Carlo dose simulation program (PENELOPE, version 2006, Universitat de Barcelona, Spain) was used to mimic these two clinical systems. The Duke University (Durham, NC) technique charts were used to determine the clinical techniques for the radiographic modalities. An exponential relationship between CTDIvol and patient diameter was used to determine the absolute dose values for CT. The simulations of the two clinical systems compute organ and tissue doses, which were then used to calculate effective dose and risk index. The calculation of the two dose metrics used the tissue weighting factors from ICRP Publication 103 and BEIR VII report. Results: The average effective dose of the chest posteroanterior examination was found to be 0.04 mSv, which was 1.3% that of the chest CT examination. The average effective dose of the chest tomosynthesis examination was found to be about ten times that of the chest posteroanterior examination and about 12% that of the chest CT examination. With increasing patient average chest diameter, both the effective dose and risk index for CT increased considerably in an exponential fashion, while these two dose metrics only increased slightly for radiographic modalities and for chest tomosynthesis. Effective and organ doses normalized to mAs all illustrated an exponential decrease with increasing patient size. As a surface organ, breast doses had less correlation with body size than that of lungs or liver. Conclusions: Patient body size has a much greater impact on radiation dose of chest CT examinations than chest radiography and tomosynthesis. The size of a patient should be considered when choosing the best thoracic imaging modality. PMID:24506654
Code of Federal Regulations, 2011 CFR
2011-01-01
... cherry tomatoes and Pyriforme type tomatoes commonly referred to as pear shaped tomatoes, and other... Standards for Fresh Tomatoes 1 Size § 51.1859 Size. (a) The size of tomatoes packed in any standard type... measurement for minimum diameter shall be the largest diameter of the tomato measured at right angles to a...
Code of Federal Regulations, 2010 CFR
2010-01-01
... cherry tomatoes and Pyriforme type tomatoes commonly referred to as pear shaped tomatoes, and other... Standards for Fresh Tomatoes 1 Size § 51.1859 Size. (a) The size of tomatoes packed in any standard type... measurement for minimum diameter shall be the largest diameter of the tomato measured at right angles to a...
Sawtarie, Nader; Cai, Yuhang; Lapitsky, Yakov
2017-09-01
Nanoparticles prepared through the ionotropic gelation of chitosan with tripolyphosphate (TPP) have been extensively studied as vehicles for drug and gene delivery. Though a number of these works have focused on preparing particles with narrow size distributions, the monodisperse particles produced by these methods have been limited to narrow size ranges (where the average particle size was not varied by more than twofold). Here we show how, by tuning the NaCl concentration in the parent chitosan and TPP solutions, low-polydispersity particles with z-average diameters ranging between roughly 100 and 900nm can be prepared. Further, we explore how the size of these particles depends on the method by which the TPP is mixed into the chitosan solution, specifically comparing: (1) single-shot mixing; (2) dropwise addition; and (3) a dilution technique, where chitosan and TPP are codissolved at a high (gelation-inhibiting) ionic strength and then diluted to lower ionic strengths to trigger gelation. Though the particle size increases sigmoidally with the NaCl concentration for all three mixing methods, the dilution method delivers the most uniform/gradual size increase - i.e., it provides the most precise control. Also investigated are the effects of mixture composition and mixing procedure on the particle yield. These reveal the particle yield to increase with the chitosan/TPP concentration, decrease with the NaCl concentration, and vary only weakly with the mixing protocol; thus, at elevated NaCl concentrations, it may be beneficial to increase chitosan and TPP concentrations to ensure high particle yields. Finally, possible pitfalls of the salt-assisted size control strategy (and their solutions) are discussed. Taken together, these findings provide a simple and reliable method for extensively tuning chitosan/TPP particle size while maintaining narrow size distributions. Copyright © 2017 Elsevier B.V. All rights reserved.
Austoni, E; Guarneri, A; Cazzaniga, A
2002-09-01
Penile augmentation surgery is a highly controversial issue due to the low level of standardisation of surgical techniques. The aim of the study is to illustrate a new technique to solve the problem of enlarging the penis by means of additive surgery on the albuginea of the corpora cavernosa, guaranteeing a real increase in size of the erect penis. Between 1995 and 1997, 39 patients who requested an increase in the diameter of their penises underwent augmentation phalloplasty with bilateral saphena grafts. The patients considered eligible for surgery were patients with either hypoplasia of the penis or functional penile dysmorphophobia. All the patients included in our study presented normal erection at screening. The average penis diameter in a flaccid state and during erection was found to be 2.1cm (1.6-2.7 cm) and 2.9 cm (2.2-3.7 cm), respectively. Before surgery the patients were informed of the experimental nature of the surgical procedure. The increase in volume of the corpora cavernosa was achieved by applying saphena grafts to longitudinal openings made bilaterally in the albuginea along the whole length of the penis. No major complications and specifically no losses of sensitivity of the penis or erection deficiencies occurred during the post-operative follow-up period. All the patients resumed their sexual activity in 4 months. A measurement of the penile dimensions was carried out 9 months after surgery. No clinical meaningful increases in the diameter of the flaccid penis were documented. The average penis diameter during erection was found to be 4.2 cm (3.4-4.9) with post-surgery increases in diameter varying from 1.1 to 2.1cm (p<0.01). The penile enlargement phalloplasty technique with albuginea surgery suggested by the authors definitely is indicated for increasing the volume of the corpora cavernosa during erection. Albuginea surgery with saphena grafts has been found to be free from aesthetic and functional complications with excellent patient satisfaction.
Contact lens overrefraction variability in corneal power estimation after refractive surgery.
Joslin, Charlotte E; Koster, James; Tu, Elmer Y
2005-12-01
To evaluate the accuracy and precision of the contact lens overrefraction (CLO) method in determining corneal refractive power in post-refractive-surgery eyes. Refractive Surgery Service and Contact Lens Service, University of Illinois, Chicago, Illinois, USA. Fourteen eyes of 7 subjects who had a single myopic laser in situ keratomileusis procedure within 12 months with refractive stability were included in this prospective case series. The CLO method was compared with the historical method of predicting the corneal power using 4 different lens fitting strategies and 3 refractive pupil scan sizes (3 mm, 5 mm, and total pupil). Rigid lenses included 3 9.0 mm overall diameter lenses fit flat, steep, and an average of the 2, and a 15.0 mm diameter lens steep fit. Cycloplegic CLO was performed using the autorefractor function of the Nidek OPD-Scan ARK-10000. Results with each strategy were compared with the corneal power estimated with the historical method. The bias (mean of the difference), 95% limits of agreement, and difference versus mean plots for each strategy are presented. In each subject, the CLO-estimated corneal power varied based on lens fit. On average, the bias between CLO and historical methods ranged from -0.38 to +2.42 diopters (D) and was significantly different from 0 in all but 3 strategies. Substantial variability in precision existed between fitting strategies, with the range of the 95% limits of agreement approximating 0.50 D in 2 strategies and 2.59 D in the worst-case scenario. The least precise fitting strategy was use of flat-fitting 9.0 mm diameter lenses. The accuracy and precision of the CLO method of estimating corneal power in post-refractive-surgery eyes was highly variable on the basis of how rigid lense were fit. One of the most commonly used fitting strategies in clinical practice--flat-fitting a 9.0 diameter lens-resulted in the poorest accuracy and precision. Results also suggest use of large-diameter lenses may improve outcomes.
Ochenjele, George; Ho, Bryant; Switaj, Paul J; Fuchs, Daniel; Goyal, Nitin; Kadakia, Anish R
2015-03-01
Jones fractures occur in the relatively avascular metadiaphyseal junction of the fifth metatarsal (MT), which predisposes these fractures to delayed union and nonunion. Operative treatment with intramedullary (IM) screw fixation is recommended in certain cases. Incorrect screw selection can lead to refractures, nonunion, and cortical blowout fractures. A better understanding of the anatomy of the fifth MT could aid in preoperative planning, guide screw size selection, and minimize complications. We retrospectively identified foot computed tomographic (CT) scans of 119 patients that met inclusion criteria. Using interactive 3-dimensional (3-D) models, the following measurements were calculated: MT length, "straight segment length" (distance from the base of the MT to the shaft curvature), and canal diameter. The diaphysis had a lateroplantar curvature where the medullary canal began to taper. The average straight segment length was 52 mm, and corresponded to 68% of the overall length of the MT from its proximal end. The medullary canal cross-section was elliptical rather than circular, with widest width in the sagittal plane and narrowest in coronal plane. The average coronal canal diameter at the isthmus was 5.0 mm. A coronal diameter greater than 4.5 mm at the isthmus was present in 81% of males and 74% of females. To our knowledge, this is the first anatomic description of the fifth metatarsal based on 3-D imaging. Excessive screw length could be avoided by keeping screw length less than 68% of the length of the fifth metatarsal. A greater than 4.5 mm diameter screw might be needed to provide adequate fixation for most study patients since the isthmus of the medullary canal for most were greater than 4.5 mm. Our results provide an improved understanding of the fifth metatarsal anatomy to guide screw diameter and length selection to maximize screw fixation and minimize complications. © The Author(s) 2014.
Wang, Xianfeng; Sun, Peipei; Han, Ningxu; Xing, Feng
2017-01-01
Encapsulation of healing agents embedded in a material matrix has become one of the major approaches for achieving self-healing function in cementitious materials in recent years. A novel type of microcapsules based self-healing cementitious composite was developed in Guangdong Provincial Key Laboratory of Durability for Marine Civil Engineering, Shenzhen University. In this study, both macro performance and the microstructure of the composite are investigated. The macro performance was evaluated by employing the compressive strength and the dynamic modulus, whereas the microstructure was represented by the pore structure parameters such as porosity, cumulative-pore volume, and average-pore diameter, which are significantly correlated to the pore-size distribution and the compressive strength. The results showed that both the compressive strength and the dynamic modulus, as well as the pore structure parameters such as porosity, cumulative-pore volume, and average-pore diameter of the specimen decrease to some extent with the amount of microcapsules. However, the self-healing rate and the recovery rate of the specimen performance and the pore-structure parameters increase with the amount of microcapsules. The results should confirm the self-healing function of microcapsules in the cementitious composite from macroscopic and microscopic viewpoints.
Wang, Xianfeng; Sun, Peipei; Han, Ningxu; Xing, Feng
2017-01-01
Encapsulation of healing agents embedded in a material matrix has become one of the major approaches for achieving self-healing function in cementitious materials in recent years. A novel type of microcapsules based self-healing cementitious composite was developed in Guangdong Provincial Key Laboratory of Durability for Marine Civil Engineering, Shenzhen University. In this study, both macro performance and the microstructure of the composite are investigated. The macro performance was evaluated by employing the compressive strength and the dynamic modulus, whereas the microstructure was represented by the pore structure parameters such as porosity, cumulative-pore volume, and average-pore diameter, which are significantly correlated to the pore-size distribution and the compressive strength. The results showed that both the compressive strength and the dynamic modulus, as well as the pore structure parameters such as porosity, cumulative-pore volume, and average-pore diameter of the specimen decrease to some extent with the amount of microcapsules. However, the self-healing rate and the recovery rate of the specimen performance and the pore-structure parameters increase with the amount of microcapsules. The results should confirm the self-healing function of microcapsules in the cementitious composite from macroscopic and microscopic viewpoints. PMID:28772382
Hydroxyapatite formation from cuttlefish bones: kinetics.
Ivankovic, H; Tkalcec, E; Orlic, S; Ferrer, G Gallego; Schauperl, Z
2010-10-01
Highly porous hydroxyapatite (Ca(10)(PO(4))(6)·(OH)(2), HA) was prepared through hydrothermal transformation of aragonitic cuttlefish bones (Sepia officinalis L. Adriatic Sea) in the temperature range from 140 to 220°C for 20 min to 48 h. The phase composition of converted hydroxyapatite was examined by quantitative X-ray diffraction (XRD) using Rietveld structure refinement and Fourier transform infrared spectroscopy (FTIR). Johnson-Mehl-Avrami (JMA) approach was used to follow the kinetics and mechanism of transformation. Diffusion controlled one dimensional growth of HA, predominantly along the a-axis, could be defined. FTIR spectroscopy determined B-type substitutions of CO(3) (2-) groups. The morphology and microstructure of converted HA was examined by scanning electron microscopy. The general architecture of cuttlefish bones was preserved after hydrothermal treatment and the cuttlefish bones retained its form with the same channel size (~80 × 300 μm). The formation of dandelion-like HA spheres with diameter from 3 to 8 μm were observed on the surface of lamellae, which further transformed into various radially oriented nanoplates and nanorods with an average diameter of about 200-300 nm and an average length of about 8-10 μm.
Angle-resolved reflection spectroscopy of high-quality PMMA opal crystal
NASA Astrophysics Data System (ADS)
Nemtsev, Ivan V.; Tambasov, Igor A.; Ivanenko, Alexander A.; Zyryanov, Victor Ya.
2018-02-01
PMMA opal crystal was prepared by a simple hybrid method, which includes sedimentation, meniscus formation and evaporation. We investigated three surfaces of this crystal by angle-resolved reflective light spectroscopy and SEM study. The angle-resolved reflective measurements were carried out in the 400-1100 nm range. We have determined the high-quality ordered surface of the crystal region. Narrow particle size distribution of the surface has been revealed. The average particle diameter obtained with SEM was nearly 361 nm. The most interesting result was that reflectivity of the surface turned out up to 98% at normal light incidence. Using a fit of dependences of the maximum reflectivity wavelength from an angle based on the Bragg-Snell law, the wavelength of maximum 0° reflectivity, the particle diameter and the fill factor have been determined. For the best surface maximum reflectivity wavelength of a 0° angle was estimated to be 869 nm. The particle diameter and fill factor were calculated as 372 nm and 0.8715, respectively. The diameter obtained by fitting is in excellent agreement with the particle diameter obtained with SEM. The reflectivity maximum is assumed to increase significantly when increasing the fill factor. We believe that using our simple approach to manufacture PMMA opal crystals will significantly increase the fabrication of high-quality photonic crystal templates and thin films.
Basic Performance Test of a Prototype PET Scanner Using CdTe Semiconductor Detectors
NASA Astrophysics Data System (ADS)
Ueno, Y.; Morimoto, Y.; Tsuchiya, K.; Yanagita, N.; Kojima, S.; Ishitsu, T.; Kitaguchi, H.; Kubo, N.; Zhao, S.; Tamaki, N.; Amemiya, K.
2009-02-01
A prototype positron emission tomography (PET) scanner using CdTe semiconductor detectors was developed, and its initial evaluation was conducted. The scanner was configured to form a single detector ring with six separated detector units, each having 96 detectors arranged in three detector layers. The field of view (FOV) size was 82 mm in diameter. Basic physical performance indicators of the scanner were measured through phantom studies and confirmed by rat imaging. The system-averaged energy resolution and timing resolution were 5.4% and 6.0 ns (each in FWHM) respectively. Spatial resolution measured at FOV center was 2.6 mm FWHM. Scatter fraction was measured and calculated in a National Electrical Manufacturers Association (NEMA)-fashioned manner using a 3-mm diameter hot capillary in a water-filled 80-mm diameter acrylic cylinder. The calculated result was 3.6%. Effect of depth of interaction (DOI) measurement was demonstrated by comparing hot-rod phantom images reconstructed with and without DOI information. Finally, images of a rat myocardium and an implanted tumor were visually assessed, and the imaging performance was confirmed.
NASA Astrophysics Data System (ADS)
Kinnard, Lisa M.; Gavrielides, Marios A.; Myers, Kyle J.; Zeng, Rongping; Peregoy, Jennifer; Pritchard, William; Karanian, John W.; Petrick, Nicholas
2008-03-01
High-resolution CT, three-dimensional (3D) methods for nodule volumetry have been introduced, with the hope that such methods will be more accurate and consistent than currently used planar measures of size. However, the error associated with volume estimation methods still needs to be quantified. Volume estimation error is multi-faceted in the sense that it is impacted by characteristics of the patient, the software tool and the CT system. The overall goal of this research is to quantify the various sources of measurement error and, when possible, minimize their effects. In the current study, we estimated nodule volume from ten repeat scans of an anthropomorphic phantom containing two synthetic spherical lung nodules (diameters: 5 and 10 mm; density: -630 HU), using a 16-slice Philips CT with 20, 50, 100 and 200 mAs exposures and 0.8 and 3.0 mm slice thicknesses. True volume was estimated from an average of diameter measurements, made using digital calipers. We report variance and bias results for volume measurements as a function of slice thickness, nodule diameter, and X-ray exposure.
NASA Technical Reports Server (NTRS)
Parker, T. J.; Pieri, D. C.
1985-01-01
Flow ejecta craters - craters surrounded by lobate ejecta blankets - are found throughout the study area. The ratio of the crater's diameter to that of the flow ejecta in this region is approximately 40 to 45%. Flow ejecta craters are dominantly sharply defined craters, with slightly degraded craters being somewhat less common. This is probably indicative of the ejecta's relatively low resistence to weathering and susceptibility to burial. Flow ejecta craters here seem to occur within a narrow range of crater sizes - the smallest being about 4km in diameter and the largest being about 27km in diameter. Ejecta blankets of craters at 4km are easily seen and those of smaller craters are simply not seen even in images with better than average resolution for the region. This may be due to the depth of excavation of small impacting bodies being insufficient to reach volatile-rich material. Flow ejecta craters above 24km are rare, and those craters above 27km do not display flow ejecta blankets. This may be a result of an excavation depth so great that the volatile content of the ejecta is insufficient to form a fluid ejecta blanket. The geomorphic/geologic unit appears also to play an important role in the formation of flow ejecta craters. Given the typical size range for the occurrence of flow ejecta craters for most units, it can be seen that the percentage of flow ejecta craters to the total number of craters within this size range varies significantly from one unit to the next. The wide variance in flow ejecta crater density over this relatively small geographical area argues strongly for a lithologic control of their distribution.
Singh, Amandeep; Vihinen, Jorma; Frankberg, Erkka; Hyvärinen, Leo; Honkanen, Mari; Levänen, Erkki
2016-12-01
This paper aims to introduce small angle X-ray scattering (SAXS) as a promising technique for measuring size and size distribution of TiO 2 nanoparticles. In this manuscript, pulsed laser ablation in liquids (PLAL) has been demonstrated as a quick and simple technique for synthesizing TiO 2 nanoparticles directly into deionized water as a suspension from titanium targets. Spherical TiO 2 nanoparticles with diameters in the range 4-35 nm were observed with transmission electron microscopy (TEM). X-ray diffraction (XRD) showed highly crystalline nanoparticles that comprised of two main photoactive phases of TiO 2 : anatase and rutile. However, presence of minor amounts of brookite was also reported. The traditional methods for nanoparticle size and size distribution analysis such as electron microscopy-based methods are time-consuming. In this study, we have proposed and validated SAXS as a promising method for characterization of laser-ablated TiO 2 nanoparticles for their size and size distribution by comparing SAXS- and TEM-measured nanoparticle size and size distribution. SAXS- and TEM-measured size distributions closely followed each other for each sample, and size distributions in both showed maxima at the same nanoparticle size. The SAXS-measured nanoparticle diameters were slightly larger than the respective diameters measured by TEM. This was because SAXS measures an agglomerate consisting of several particles as one big particle which slightly increased the mean diameter. TEM- and SAXS-measured mean diameters when plotted together showed similar trend in the variation in the size as the laser power was changed which along with extremely similar size distributions for TEM and SAXS validated the application of SAXS for size distribution measurement of the synthesized TiO 2 nanoparticles.
Development of miniature, high frequency pulse tube cryocoolers
NASA Astrophysics Data System (ADS)
Radebaugh, Ray; Garaway, Isaac; Veprik, Alexander M.
2010-04-01
Because acoustic power density is proportional to frequency, the size of pulse tube cryocoolers for a given refrigeration power can be reduced by operating them at higher frequencies. A frequency of about 60 Hz had been considered the maximum frequency that could be used while maintaining high efficiency. Recently, we have shown through modeling that by decreasing the volume and hydraulic diameter of the regenerator and increasing the average pressure, it is possible to maintain high efficiency even for frequencies of several hundred hertz. Subsequent experimental results have demonstrated high efficiencies for frequencies of 100 to 140 Hz. The very high power density achieved at higher pressures and higher frequencies leads to very short cooldown times and very compact devices. The use of even higher frequencies requires the development of special compressors designed for such conditions and the development of regenerator matrices with hydraulic diameters less than about 30 Μm. To demonstrate the advantages of higher frequency operation, we discuss here the development of a miniature pulse tube cryocooler designed to operate at 80 K with a frequency of 150 Hz and an average pressure of 5.0 MPa. The regenerator diameter and length are 4.4 mm and 27 mm, respectively. The lowest temperature achieved to date has been 97 K, but a net refrigeration power of 530 mW was achieved at 120 K. Acoustic mismatches with existing compressors significantly limit the efficiency, but necessary modifications to improve the acoustic impedance match between the compressor and the cold head are discussed briefly.
Pan, Ying; Zhang, Yunshu; Peng, Yan; Zhao, Qinghua; Sun, Shucun
2015-01-01
Aquatic microcosm studies often increase either chamber height or base diameter (to increase water volume) to test spatial ecology theories such as "scale" effects on ecological processes, but it is unclear whether the increase of chamber height or base diameter have the same effect on the processes, i.e., whether the effect of the shape of three-dimensional spaces is significant. We orthogonally manipulated chamber height and base diameter and determined swimming activity, average swimming velocity and grazing rates of the cladocerans Daphnia magna and Moina micrura (on two algae Scenedesmus quadricauda and Chlorella vulgaris; leading to four aquatic algae-cladoceran systems in total) under different microcosm conditions. Across all the four aquatic systems, increasing chamber height at a given base diameter significantly decreased the duration and velocity of horizontal swimming, and it tended to increase the duration but decrease the velocity of vertical swimming. These collectively led to decreases in both average swimming velocity and grazing rate of the cladocerans in the tall chambers (at a given base diameter), in accordance with the positive relationship between average swimming velocity and grazing rate. In contrast, an increase of base diameter at a given chamber height showed contrasting effects on the above parameters. Consistently, at a given chamber volume increasing ratio of chamber height to base diameter decreased the average swimming velocity and grazing rate across all the aquatic systems. In general, increasing chamber depth and base diameter may exert contrasting effects on zooplankton behavior and thus phytoplankton-zooplankton interactions. We suggest that spatial shape plays an important role in determining ecological process and thus should be considered in a theoretical framework of spatial ecology and also the physical setting of aquatic microcosm experiments.
Pan, Ying; Zhang, Yunshu; Peng, Yan; Zhao, Qinghua; Sun, Shucun
2015-01-01
Aquatic microcosm studies often increase either chamber height or base diameter (to increase water volume) to test spatial ecology theories such as “scale” effects on ecological processes, but it is unclear whether the increase of chamber height or base diameter have the same effect on the processes, i.e., whether the effect of the shape of three-dimensional spaces is significant. We orthogonally manipulated chamber height and base diameter and determined swimming activity, average swimming velocity and grazing rates of the cladocerans Daphnia magna and Moina micrura (on two algae Scenedesmus quadricauda and Chlorella vulgaris; leading to four aquatic algae-cladoceran systems in total) under different microcosm conditions. Across all the four aquatic systems, increasing chamber height at a given base diameter significantly decreased the duration and velocity of horizontal swimming, and it tended to increase the duration but decrease the velocity of vertical swimming. These collectively led to decreases in both average swimming velocity and grazing rate of the cladocerans in the tall chambers (at a given base diameter), in accordance with the positive relationship between average swimming velocity and grazing rate. In contrast, an increase of base diameter at a given chamber height showed contrasting effects on the above parameters. Consistently, at a given chamber volume increasing ratio of chamber height to base diameter decreased the average swimming velocity and grazing rate across all the aquatic systems. In general, increasing chamber depth and base diameter may exert contrasting effects on zooplankton behavior and thus phytoplankton-zooplankton interactions. We suggest that spatial shape plays an important role in determining ecological process and thus should be considered in a theoretical framework of spatial ecology and also the physical setting of aquatic microcosm experiments. PMID:26273836
Comparison of parameters affecting GNP-loaded choroidal melanoma dosimetry; Monte Carlo study
NASA Astrophysics Data System (ADS)
Sharabiani, Marjan; Asadi, Somayeh; Barghi, Amir Rahnamai; Vaezzadeh, Mehdi
2018-04-01
The current study reports the results of tumor dosimetry in the presence of gold nanoparticles (GNPs) with different sizes and concentrations. Due to limited number of works carried out on the brachytherapy of choroidal melanoma in combination with GNPs, this study was performed to determine the optimum size and concentration for GNPs which contributes the highest dose deposition in tumor region, using two phantom test cases namely water phantom and a full Monte Carlo model of human eye. Both water and human eye phantoms were simulated with MCNP5 code. Tumor dosimetry was performed for a typical point photon source with an energy of 0.38 MeV as a high energy source and 103Pd brachytherapy source with an average energy of 0.021 MeV as a low energy source in water phantom and eye phantom respectively. Such a dosimetry was done for different sizes and concentrations of GNPs. For all of the diameters, increase in concentration of GNPs resulted in an increase in dose deposited in the region of interest. In a certain concentration, GNPs with larger diameters contributed more dose to the tumor region, which was more pronounced using eye phantom. 100 nm was reported as the optimum size in order to achieve the highest energy deposition within the target. This work investigated the optimum parameters affecting macroscopic dose enhancement in GNP-aided brachytherapy of choroidal melanoma. The current work also had implications on using low energy photon sources in the presence of GNPs to acquire the highest dose enhancement. This study is conducted through four different sizes and concentrations of GNPs. Considering the sensitivity of human eye tissue, in order to report the precise optimum parameters affecting radiosensitivity, a comprehensive study on a wide range of sizes and concentrations are required.
NASA Astrophysics Data System (ADS)
Hartman, John; Kirby, Brian
2017-03-01
Nanoparticle tracking analysis, a multiprobe single particle tracking technique, is a widely used method to quickly determine the concentration and size distribution of colloidal particle suspensions. Many popular tools remove non-Brownian components of particle motion by subtracting the ensemble-average displacement at each time step, which is termed dedrifting. Though critical for accurate size measurements, dedrifting is shown here to introduce significant biasing error and can fundamentally limit the dynamic range of particle size that can be measured for dilute heterogeneous suspensions such as biological extracellular vesicles. We report a more accurate estimate of particle mean-square displacement, which we call decorrelation analysis, that accounts for correlations between individual and ensemble particle motion, which are spuriously introduced by dedrifting. Particle tracking simulation and experimental results show that this approach more accurately determines particle diameters for low-concentration polydisperse suspensions when compared with standard dedrifting techniques.
A study of scandia and rhenium doped tungsten matrix dispenser cathode
NASA Astrophysics Data System (ADS)
Wang, Jinshu; Li, Lili; Liu, Wei; Wang, Yanchun; Zhao, Lei; Zhou, Meiling
2007-10-01
Scandia and rhenium doped tungsten powders were prepared by solid-liquid doping combined with two-step reduction method. The experimental results show that scandia was distributed evenly on the surface of tungsten particles. The addition of scandia and rhenium could decrease the particle size of doped tungsten, for example, the tungsten powders doped with Sc 2O 3 and Re had the average size of about 50 nm in diameter. By using this kind of powder, scandia and rhenium doped tungsten matrix with the sub-micrometer sized tungsten grains was obtained. This kind of matrix exhibited good anti-bombardment insensitivity at high temperature. The emission property result showed that high space charge limited current densities of more than 60 A/cm 2 at 900 °C could be obtained for this cathode. A Ba-Sc-O multilayer about 100 nm in thickness formed at the surface of cathode after activation led to the high emission property.
Josberger, E.G.; Gloersen, P.; Chang, A.; Rango, A.
1996-01-01
Understanding the passive microwave emissions of a snowpack, as observed by satellite sensors, requires knowledge of the snowpack properties: water equivalent, grain size, density, and stratigraphy. For the snowpack in the Upper Colorado River Basin, measurements of snow depth and water equivalent are routinely available from the U.S. Department of Agriculture, but extremely limited information is available for the other properties. To provide this information, a field program from 1984 to 1995 obtained profiles of snowpack grain size, density, and temperature near the time of maximum snow accumulation, at sites distributed across the basin. A synoptic basin-wide sampling program in 1985 showed that the snowpack exhibits consistent properties across large regions. Typically, the snowpack in the Wyoming region contains large amounts of depth hoar, with grain sizes up to 5 mm, while the snowpack in Colorado and Utah is dominated by rounded snow grains less than 2 mm in diameter. In the Wyoming region, large depth hoar crystals in shallow snowpacks yield the lowest emissivities or coldest brightness temperatures observed across the entire basin. Yearly differences in the average grain sizes result primarily from variations in the relative amount of depth hoar within the snowpack. The average grain size for the Colorado and Utah regions shows much less variation than do the grain sizes from the Wyoming region. Furthermore, the greatest amounts of depth hoar occur in the Wyoming region during 1987 and 1992, years with strong El Nin??o Southern Oscillation, but the Colorado and Utah regions do not show this behavior.
[Preparation of Oenothera biennis Oil Solid Lipid Nanoparticles Based on Microemulsion Technique].
Piao, Lin-mei; Jin, Yong; Cui, Yan-lin; Yin, Shou-yu
2015-06-01
To study the preparation of Oenothera biennis oil solid lipid nanoparticles and its quality evaluation. The solid lipid nanoparticles were prepared by microemulsion technique. The optimum condition was performed based on the orthogonal design to examine the entrapment efficiency, the mean diameter of the particles and so on. The optimal preparation of Oenothera biennis oil solid lipid nanoparticles was as follows: Oenothera biennis dosage 300 mg, glycerol monostearate-Oenothera biennis (2: 3), Oenothera biennis -RH/40/PEG-400 (1: 2), RH-40/PEG-400 (1: 2). The resulting nanoparticles average encapsulation efficiency was (89.89 ± 0.71)%, the average particle size was 44.43 ± 0.08 nm, and the Zeta potential was 64.72 ± 1.24 mV. The preparation process is simple, stable and feasible.
Establishment of gold-quartz standard GQS-1
Millard, Hugh T.; Marinenko, John; McLane, John E.
1969-01-01
A homogeneous gold-quartz standard, GQS-1, was prepared from a heterogeneous gold-bearing quartz by chemical treatment. The concentration of gold in GQS-1 was determined by both instrumental neutron activation analysis and radioisotope dilution analysis to be 2.61?0.10 parts per million. Analysis of 10 samples of the standard by both instrumental neutron activation analysis and radioisotope dilution analysis failed to reveal heterogeneity within the standard. The precision of the analytical methods, expressed as standard error, was approximately 0.1 part per million. The analytical data were also used to estimate the average size of gold particles. The chemical treatment apparently reduced the average diameter of the gold particles by at least an order of magnitude and increased the concentration of gold grains by a factor of at least 4,000.
Moon-Mercury: Large impact structures, isostasy and average crustal viscosity
Schaber, G.G.; Boyce, J.M.; Trask, N.J.
1977-01-01
Thirty-five craters and basins larger than 200 km in diameter are recognized on the imaged portion (45%) of Mercury. If the unimaged portion of the planet is similarly cratered, a total of 78 such impact features may be present. Sixty-two craters and basins 200 km in diameter are recognized on the moon, a body with only half the cross-sectional area of Mercury. If surface areas are considered, however, Mercury is cratered only 70% as densely as the moon. The density of impact craters with diameters greater than 400 km on Mercury is only 30% of that on the moon, and for craters with diameters between 400 and 700 km, the density on Mercury is only 21% of the lunar crater density. The size-frequency distribution curve for the large Mercurian craters follows the same cumulative -2 slope as the lunar curve but lies well below the 10% surface saturation level characteristic of the lunar curve. This is taken as evidence that the old heavily cratered terrain on Mercury is, at least presently, not in a state of cratering equilibrium. The reduced density of large craters and basins on Mercury relative to the moon could be either a function of the crater-production rates on these bodies or an effect of different crustal histories. Resurfacing of the planet after the basin-forming period is ruled out by the presence of 54 craters and basins 100 km in diameter and larger (on the imaged portion of Mercury) that have either well-defined or poorly-defined secondary-crater fields. Total isostatic compensation of impact craters ???800 km in diameter indicates that the average viscosity of the Mercurian crust over the past 4+ aeons was the same as that for the moon (???1026.5 P). This calculated viscosity and the distribution of large craters and basins suggest that either the very early crustal viscosity on Mercury was less than that of the moon and the present viscosity greater, or the differences in large crater populations on the two bodies is indeed the result of variations in rates of crater production. ?? 1977.
Peinetti, Ana S; Mizrahi, Martín; Requejo, Félix G; Buceta, David; López-Quintela, M Arturo; González, Graciela A; Battaglini, Fernando
2018-04-15
Non-noble metal nanoclusters synthesis is receiving increased attention due to their unique catalytic properties and lower cost. Herein, the synthesis of ligand-free Ni nanoclusters with an average diameter of 0.7 nm corresponding to a structure of 13 atoms is presented; they exhibit a zero-valence state and a high stability toward oxidation and thermal treatment. The nanoclusters formation method consists in the electroreduction of nickel ions inside an ordered mesoporous alumina; also, by increasing the current density, other structures can be obtained reaching to nanowires of 10 nm diameter. A seed-mediated mechanism is proposed to explain the growth to nanowires inside these mesoporous cavities. The size dependence on the catalytic behavior of these entities is illustrated by studying the reduction of methylene blue where the nanoclusters show an outstanding performance. Copyright © 2018 Elsevier Inc. All rights reserved.
Laser myringotomy with the CO2 Otoscan laser
NASA Astrophysics Data System (ADS)
Sedlmaier, Benedikt W.; Jivanjee, Antonio; Schoenfeld, Uwe; Jovanovic, Sergije
2000-06-01
Tympanic ventilation is the treatment of choice for otitis media with effusion (OME). CO2 laser myringotomy has already proven its value and is finding increasing clinical application. The ventilation time in the middle ear is essentially determined by the size of the laser perforation. Perforations exceeding 2 mm in diameter enable tympanic ventilation for about three weeks and thus compete with the ventilation tube in the treatment of OME. IN a prospective study, laser myringotomy is performed in 84 children with OME with the new CO2 laser otoscope Otoscan. The closure time was 17 days in average for a preformation diameter of 2 mm. In the further clinical course, the ear-drums healed without atrophic scar formation. In an observation period of six month the recurrency rate of effusion was approximately 10 percent. Laser myringotomy seems to be an useful method in the operative therapy of secretory otitis media.
Gas refractometry based on an all-fiber spatial optical filter.
Silva, Susana; Coelho, L; André, R M; Frazão, O
2012-08-15
A spatial optical filter based on splice misalignment between optical fibers with different diameters is proposed for gas refractometry. The sensing head is formed by a 2 mm long optical fiber with 50 μm diameter that is spliced with a strong misalignment between two single-mode fibers (SMF28) and interrogated in transmission. The misalignment causes a Fabry-Perot behavior along the reduced-size fiber and depending on the lead-out SMF28 position, it is possible to obtain different spectral responses, namely, bandpass or band-rejection filters. It is shown that the spatial filter device is highly sensitive to refractive index changes on a nitrogen environment by means of the gas pressure variation. A maximum sensitivity of -1390 nm/RIU for the bandpass filter was achieved. Both devices have shown similar temperature responses with an average sensitivity of 25.7 pm/°C.
Performance Evaluation and Initial Clinical Test of the Positron Emission Mammography System (PEMi)
NASA Astrophysics Data System (ADS)
Li, Lin; Gu, Xiao-Yue; Li, Dao-Wu; Huang, Xian-Chao; Chai, Pei; Feng, Bao-Tong; Wang, Pei-Lin; Yun, Ming-Kai; Dai, Dong; Zhang, Zhi-Ming; Yin, Peng-Fei; Xu, Wen-Gui; Wei, Long
2015-10-01
A new polygon positron emission mammography imaging system (PEMi) was developed in 2009 by the Institute of High Energy Physics, Chinese Academy of Sciences. PEMi is constructed in a polygon structure with lutetium yttrium orthosilicate crystal arrays mounted on a position-sensitive photomultiplier. The system consists of 64 blocks and each block is arranged in 16 ×16 crystal arrays with a pixel size of 1.9 ×1.9 ×15 mm. The diameter of the detector ring is 166 mm, and the axial length is 128 mm. The transaxial field of view of PEMi is 110 mm. The goal of the initial study was to test PEMi's performance and the clinical imaging ability with a small group of selected subjects. The detectors have a measured intrinsic spatial resolution averaging 1.67 mm. The axial and tangential resolution remained under 2.5-mm full width at half maximum within the central 5-cm diameter of the field of view. The hot rods with a diameter of 1.7 mm can be clearly identified, and the structure of the region containing 1.35-mm diameter rods can also be observed. Using a 6-ns coincidence timing window and a 360 660-keV energy window, the peak sensitivity of the tomograph is 6.88%. The noise-equivalent count rate peak is 110 766 cps for a breast-like cylindrical phantom of 100 mm in diameter at an activity concentration of 0.03 MBq/cc. The recovery coefficients ranged from 0.21 to 0.85 for rods between 1 mm and 5 mm in the image-quality phantom. The reconstructed image resolution achieved an improvement compared with whole-body positron emission tomography (PET), which might reduce the lower threshold on detectable lesion size. Example patient images demonstrate that PEMi is clinically feasible. And more detailed structure information was obtained with PEMi than with the whole-body PET imaging.
The Pressure-Dependence of the Size of Extruded Vesicles
Patty, Philipus J.; Frisken, Barbara J.
2003-01-01
Variations in the size of vesicles formed by extrusion through small pores are discussed in terms of a simple model. Our model predicts that the radius should decrease as the square root of the applied pressure, consistent with data for vesicles extruded under various conditions. The model also predicts dependencies on the pore size used and on the lysis tension of the vesicles being extruded that are consistent with our data. The pore size was varied by using track-etched polycarbonate membranes with average pore diameters ranging from 50 to 200 nm. To vary the lysis tension, vesicles made from POPC (1-palmitoyl-2-oleoyl-sn-glycero-3-phosphatidylcholine), mixtures of POPC and cholesterol, and mixtures of POPC and C16-ceramide were studied. The lysis tension, as measured by an extrusion-based technique, of POPC:cholesterol vesicles is higher than that of pure POPC vesicles whereas POPC:ceramide vesicles have lower lysis tensions than POPC vesicles. PMID:12885646
Reduced clot debris size using standing waves formed via high intensity focused ultrasound
NASA Astrophysics Data System (ADS)
Guo, Shifang; Du, Xuan; Wang, Xin; Lu, Shukuan; Shi, Aiwei; Xu, Shanshan; Bouakaz, Ayache; Wan, Mingxi
2017-09-01
The feasibility of utilizing high intensity focused ultrasound (HIFU) to induce thrombolysis has been demonstrated previously. However, clinical concerns still remain related to the clot debris produced via fragmentation of the original clot potentially being too large and hence occluding downstream vessels, causing hazardous emboli. This study investigates the use of standing wave fields formed via HIFU to disintegrate the thrombus while achieving a reduced clot debris size in vitro. The results showed that the average diameter of the clot debris calculated by volume percentage was smaller in the standing wave mode than in the travelling wave mode at identical ultrasound thrombolysis settings. Furthermore, the inertial cavitation dose was shown to be lower in the standing wave mode, while the estimated cavitation bubble size distribution was similar in both modes. These results show that a reduction of the clot debris size with standing waves may be attributed to the particle trapping of the acoustic potential well which contributed to particle fragmentation.
Characterizing property distributions of polymeric nanogels by size-exclusion chromatography.
Mourey, Thomas H; Leon, Jeffrey W; Bennett, James R; Bryan, Trevor G; Slater, Lisa A; Balke, Stephen T
2007-03-30
Nanogels are highly branched, swellable polymer structures with average diameters between 1 and 100nm. Size-exclusion chromatography (SEC) fractionates materials in this size range, and it is commonly used to measure nanogel molar mass distributions. For many nanogel applications, it may be more important to calculate the particle size distribution from the SEC data than it is to calculate the molar mass distribution. Other useful nanogel property distributions include particle shape, area, and volume, as well as polymer volume fraction per particle. All can be obtained from multi-detector SEC data with proper calibration and data analysis methods. This work develops the basic equations for calculating several of these differential and cumulative property distributions and applies them to SEC data from the analysis of polymeric nanogels. The methods are analogous to those used to calculate the more familiar SEC molar mass distributions. Calibration methods and characteristics of the distributions are discussed, and the effects of detector noise and mismatched concentration and molar mass sensitive detector signals are examined.
Counting polymers moving through a single ion channel
NASA Astrophysics Data System (ADS)
Bezrukov, Sergey M.; Vodyanoy, Igor; Parsegian, V. Adrian
1994-07-01
THE change in conductance of a small electrolyte-filled capillary owing to the passage of sub-micrometre-sized particles has long been used for particle counting and sizing. A commercial device for such measurements, the Coulter counter, is able to detect particles of sizes down to several tenths of a micrometre1-3. Nuclepore technology (in which pores are etched particle tracks) has extended the lower limit of size detection to 60-nm particles by using a capillary of diameter 0.45 μm (ref. 4). Here we show that natural channel-forming peptides incorporated into a bilayer lipid membrane can be used to detect the passage of single molecules with gyration radii as small as 5-15 Å. From our experiments with alamethicin pores we infer both the average number and the diffusion coefficients of poly(ethylene glycol) molecules in the pore. Our approach provides a means of observing the statistics and mechanics of flexible polymers moving within the confines of precisely defined single-molecule structures.
Effect of Particle Size on Thermal Conductivity of Nanofluid
NASA Astrophysics Data System (ADS)
Chopkar, M.; Sudarshan, S.; Das, P. K.; Manna, I.
2008-07-01
Nanofluids, containing nanometric metallic or oxide particles, exhibit extraordinarily high thermal conductivity. It is reported that the identity (composition), amount (volume percent), size, and shape of nanoparticles largely determine the extent of this enhancement. In the present study, we have experimentally investigated the impact of Al2Cu and Ag2Al nanoparticle size and volume fraction on the effective thermal conductivity of water and ethylene glycol based nanofluid prepared by a two-stage process comprising mechanical alloying of appropriate Al-Cu and Al-Ag elemental powder blend followed by dispersing these nanoparticles (1 to 2 vol pct) in water and ethylene glycol with different particle sizes. The thermal conductivity ratio of nanofluid, measured using an indigenously developed thermal comparator device, shows a significant increase of up to 100 pct with only 1.5 vol pct nanoparticles of 30- to 40-nm average diameter. Furthermore, an analytical model shows that the interfacial layer significantly influences the effective thermal conductivity ratio of nanofluid for the comparable amount of nanoparticles.
Effect of MUF/Epoxy Microcapsules on Mechanical Properties and Fractography of Epoxy Materials
NASA Astrophysics Data System (ADS)
Ni, Zhuo; Lin, Yuhao; Du, Xuexiao
2017-12-01
Melamine-urea-formaldehyde (MUF) microcapsules were synthesized, morphology, shell thickness, average diameter and interface morphology were studied by scanning electron microscope (SEM). The spherical MUF microcapsules are size normal distribution without adhesion and accumulation, being compact, rough and uneven with a thickness of 3.2μm and a core contents is approximate 70%. A latent imidazoleas the curing agent for a cross-linking chemical reaction for cracking repairing. A good dispersion of MUF microcapsules and a good interfacial bonding are obtained. Effects of MUF microcapsule size and content on bending property and dynamic mechanical propertywere investigated. Both bending strength and storage modulus of the composite are considerably reduced with an increasing addition of the microcapsules whereas the glass transition temperatures are almost not influenced. Significant toughening effects of MUF microcapsules on the epoxy composites are observed at the conditions of different content and size of microcapsule especially at low microcapsule contents and small microcapsule sizes.
Gravitational acceleration as a cue for absolute size and distance?
NASA Technical Reports Server (NTRS)
Hecht, H.; Kaiser, M. K.; Banks, M. S.
1996-01-01
When an object's motion is influenced by gravity, as in the rise and fall of a thrown ball, the vertical component of acceleration is roughly constant at 9.8 m/sec2. In principle, an observer could use this information to estimate the absolute size and distance of the object (Saxberg, 1987a; Watson, Banks, von Hofsten, & Royden, 1992). In five experiments, we examined people's ability to utilize the size and distance information provided by gravitational acceleration. Observers viewed computer simulations of an object rising and falling on a trajectory aligned with the gravitational vector. The simulated objects were balls of different diameters presented across a wide range of simulated distances. Observers were asked to identify the ball that was presented and to estimate its distance. The results showed that observers were much more sensitive to average velocity than to the gravitational acceleration pattern. Likewise, verticality of the motion and visibility of the trajectory's apex had negligible effects on the accuracy of size and distance judgments.
NASA Astrophysics Data System (ADS)
Sliwinska-Bartkowiak, Malgorzata; Dudziak, Grazyna; Sikorski, Roman; Gras, Roman; Radhakrishnan, Ravi; Gubbins, Keith E.
2001-01-01
We report both experimental measurements and molecular simulations of the melting and freezing behavior of fluids in nanoporous media. The experimental studies are for nitrobenzene in the silica-based pores of controlled pore glass, Vycor, and MCM-41. Dielectric relaxation spectroscopy is used to determine melting points and the orientational relaxation times of the nitrobenzene molecules in the bulk and the confined phase. Monte Carlo simulations, together with a bond orientational order parameter method, are used to determine the melting point and fluid structure inside cylindrical pores modeled on silica. Qualitative comparison between experiment and simulation are made for the shift in the freezing temperatures and the structure of confined phases. From both the experiments and the simulations, it is found that the confined fluid freezes into a single crystalline structure for average pore diameters greater than 20σ, where σ is the diameter of the fluid molecule. For average pore sizes between 20σ and 15σ, part of the confined fluid freezes into a frustrated crystal structure with the rest forming an amorphous region. For pore sizes smaller than 15σ, even the partial crystallization did not occur. Our measurements and calculations show clear evidence of a novel intermediate "contact layer" phase lying between liquid and crystal; the contact layer is the confined molecular layer adjacent to the pore wall and experiences a deeper fluid-wall potential energy compared to the inner layers. We also find evidence of a liquid to "hexatic" transition in the quasi-two-dimensional contact layer at high temperatures.
Drop-on-demand inkjet-based cell printing with 30-μm nozzle diameter for cell-level accuracy
Kim, Young Kwon; Yoon, Woong Hee; Kim, Joonwon; Jung, Sungjune
2016-01-01
We present drop-on-demand inkjet-based mammalian cell printing with a 30-μm nozzle diameter for cell-level accuracy. High-speed imaging techniques have been used to analyze the go-and-stop movement of cells inside the nozzle under a pulsed pressure generated by a piezo-actuator and the jet formation after ejection. Patterning of an array of 20 × 20 dots on a glass substrate reveals that each printed drop contains 1.30 cells on average at the cell concentration of 5.0 × 106 cells ml−1 for the very small nozzle, whereas larger nozzles with the diameter of 50 and 80 μm deliver 2.57 and 2.88 cells per drop, respectively. The effects of the size and concentration of printed cells on the number of cells have also been investigated. Furthermore, the effect of the nozzle diameter on printed cells has been evaluated through an examination of viability, proliferation, and morphology of cells by using a live/dead assay kit, CCK-8 assay, and cellular morphology imaging, respectively. We believe that the 30-μm inkjet nozzle can be used for precise cell deposition without any damages to the printed mammalian cells. PMID:27990212
On the averaging area for incident power density for human exposure limits at frequencies over 6 GHz
NASA Astrophysics Data System (ADS)
Hashimoto, Yota; Hirata, Akimasa; Morimoto, Ryota; Aonuma, Shinta; Laakso, Ilkka; Jokela, Kari; Foster, Kenneth R.
2017-04-01
Incident power density is used as the dosimetric quantity to specify the restrictions on human exposure to electromagnetic fields at frequencies above 3 or 10 GHz in order to prevent excessive temperature elevation at the body surface. However, international standards and guidelines have different definitions for the size of the area over which the power density should be averaged. This study reports computational evaluation of the relationship between the size of the area over which incident power density is averaged and the local peak temperature elevation in a multi-layer model simulating a human body. Three wave sources are considered in the frequency range from 3 to 300 GHz: an ideal beam, a half-wave dipole antenna, and an antenna array. 1D analysis shows that averaging area of 20 mm × 20 mm is a good measure to correlate with the local peak temperature elevation when the field distribution is nearly uniform in that area. The averaging area is different from recommendations in the current international standards/guidelines, and not dependent on the frequency. For a non-uniform field distribution, such as a beam with small diameter, the incident power density should be compensated by multiplying a factor that can be derived from the ratio of the effective beam area to the averaging area. The findings in the present study suggest that the relationship obtained using the 1D approximation is applicable for deriving the relationship between the incident power density and the local temperature elevation.
Rogers, Kim R; Navratilova, Jana; Stefaniak, Aleksandr; Bowers, Lauren; Knepp, Alycia K; Al-Abed, Souhail R; Potter, Phillip; Gitipour, Alireza; Radwan, Islam; Nelson, Clay; Bradham, Karen D
2018-04-01
Given the potential for human exposure to silver nanoparticles from spray disinfectants and dietary supplements, we characterized the silver-containing nanoparticles in 22 commercial products that advertised the use of silver or colloidal silver as the active ingredient. Characterization parameters included: total silver, fractionated silver (particulate and dissolved), primary particle size distribution, hydrodynamic diameter, particle number, and plasmon resonance absorbance. A high degree of variability between claimed and measured values for total silver was observed. Only 7 of the products showed total silver concentrations within 20% of their nominally reported values. In addition, significant variations in the relative percentages of particulate vs. soluble silver were also measured in many of these products reporting to be colloidal. Primary silver particle size distributions by transmission electron microscopy (TEM) showed two populations of particles - smaller particles (<5nm) and larger particles between 20 and 40nm. Hydrodynamic diameter measurements using nanoparticle tracking analysis (NTA) correlated well with TEM analysis for the larger particles. Z-average (Z-Avg) values measured using dynamic light scattering (DLS); however, were typically larger than both NTA or TEM particle diameters. Plasmon resonance absorbance signatures (peak absorbance at around 400nm indicative of metallic silver nanoparticles) were only noted in 4 of the 9 yellow-brown colored suspensions. Although the total silver concentrations were variable among products, ranging from 0.54mg/L to 960mg/L, silver containing nanoparticles were identified in all of the product suspensions by TEM. Published by Elsevier B.V.
Latimer, Cassandra A; Nelson, Meghan; Moore, Camille M; Martin, Kimberly E
2014-01-01
Bipolar devices are routinely used to seal blood vessels instead of sutures and clips. Recent work examining the impact of vascular proteins on bipolar seal performance found that collagen and elastin (CE) content within porcine arteries was a significant predictor of a vessel's burst pressure (VBPr). This study examined seal performance across a range of human blood vessels to investigate whether a similar relationship existed. In addition, we compared VBPr and CE content between porcine and human blood vessels. Our primary hypothesis is that higher collagen-to-elastin ratio will predict higher VBPr in human vasculature. In six cadavers, 185 blood vessels from nine anatomic locations were sealed using a bipolar electrosurgical system. A linear mixed model framework was used to evaluate the impact of vessel diameter and CE content on VBPr. The effect of CE ratio on VBPr is modified by vessel size, with CE ratio having larger influence on VBPr in smaller diameter vessels. Seal burst pressure of vessels 2-5 mm in diameter was significantly associated with their CE content. Comparison of average VBPr between species revealed porcine carotid and iliac arteries (440-670 mmHg) to be the best vessel types for predicting the seal strength of most human blood vessels (420-570 mmHg) examined. CE content significantly modified the seal strength of small to medium sized blood vessels but had limited impact on vessels >5 mm. Copyright © 2014 Elsevier Inc. All rights reserved.
Pupillographic assessment of sleepiness in sleep-deprived healthy subjects.
Wilhelm, B; Wilhelm, H; Lüdtke, H; Streicher, P; Adler, M
1998-05-01
Spontaneous pupillary-behavior in darkness provides information about a subject's level of sleepiness. In the present work, pupil measurements in complete darkness and quiet have been recorded continuously over 11-minute period with infrared video pupillography at 25 Hz. The data have been analyzed to yield three parameters describing pupil behavior; the power of diameter variation at frequencies below 0.8 Hz (slow changes in pupil size), the pupillary unrest index, and the average pupil size. To investigate the changes of these parameters in sleep deprivation, spontaneous pupillary behavior in darkness was recorded every 2 hours in 13 healthy subjects from 19:00 to 07:00 during forced wakefulness. On each occasion, comparative subjective sleepiness was assessed with a self-rating scale (Stanford Sleepiness Scale, SSS). The power of slow pupillary oscillations (< or = 0.8 Hz) increased significantly and so did the values of SSS, while basic pupil diameter decreased significantly. Slow pupillary oscillations and SSS did not correlate well in general but high values of pupil parameters were always associated with high values in subjective rating. Our results demonstrate a strong relationship between ongoing sleep deprivation and typical changes in the frequency profiles of spontaneous pupillary oscillations and the tendency to instability in pupil size in normals. These findings suggest that the results of pupil data analysis permit an objective measurement of sleepiness.
Role of tree size in moist tropical forest carbon cycling and water deficit responses.
Meakem, Victoria; Tepley, Alan J; Gonzalez-Akre, Erika B; Herrmann, Valentine; Muller-Landau, Helene C; Wright, S Joseph; Hubbell, Stephen P; Condit, Richard; Anderson-Teixeira, Kristina J
2017-06-06
Drought disproportionately affects larger trees in tropical forests, but implications for forest composition and carbon (C) cycling in relation to dry season intensity remain poorly understood. In order to characterize how C cycling is shaped by tree size and drought adaptations and how these patterns relate to spatial and temporal variation in water deficit, we analyze data from three forest dynamics plots spanning a moisture gradient in Panama that have experienced El Niño droughts. At all sites, aboveground C cycle contributions peaked below 50-cm stem diameter, with stems ≥ 50 cm accounting for on average 59% of live aboveground biomass, 45% of woody productivity and 49% of woody mortality. The dominance of drought-avoidance strategies increased interactively with stem diameter and dry season intensity. Although size-related C cycle contributions did not vary systematically across the moisture gradient under nondrought conditions, woody mortality of larger trees was disproportionately elevated under El Niño drought stress. Thus, large (> 50 cm) stems, which strongly mediate but do not necessarily dominate C cycling, have drought adaptations that compensate for their more challenging hydraulic environment, particularly in drier climates. However, these adaptations do not fully buffer the effects of severe drought, and increased large tree mortality dominates ecosystem-level drought responses. © 2017 Smithsonian. Institute New Phytologist © 2017 New Phytologist Trust.
Digital Pupillometry in Normal Subjects
Rickmann, Annekatrin; Waizel, Maria; Kazerounian, Sara; Szurman, Peter; Wilhelm, Helmut; Boden, Karl T.
2017-01-01
ABSTRACT The aim of this study was to evaluate the pupil size of normal subjects at different illumination levels with a novel pupillometer. The pupil size of healthy study participants was measured with an infrared-video PupilX pupillometer (MEye Tech GmbH, Alsdorf, Germany) at five different illumination levels (0, 0.5, 4, 32, and 250 lux). Measurements were performed by the same investigator. Ninety images were executed during a measurement period of 3 seconds. The absolute linear camera resolution was approximately 20 pixels per mm. This cross-sectional study analysed 490 eyes of 245 subjects (mean age: 51.9 ± 18.3 years, range: 6–87 years). On average, pupil diameter decreased with increasing light intensities for both eyes, with a mean pupil diameter of 5.39 ± 1.04 mm at 0 lux, 5.20 ± 1.00 mm at 0.5 lux, 4.70 ± 0.97 mm at 4 lux, 3.74 ± 0.78 mm at 32 lux, and 2.84 ± 0.50 mm at 250 lux illumination. Furthermore, it was found that anisocoria increased by 0.03 mm per life decade for all illumination levels (R2 = 0.43). Anisocoria was higher under scotopic and mesopic conditions. This study provides additional information to the current knowledge concerning age- and light-related pupil size and anisocoria as a baseline for future patient studies. PMID:28228832
Feng, Ai-Ling; Wang, Ying-Zi; Zhang, Sheng-Hai; Sun, Xiu-Yu; Duan, Fei-Peng; Li, Cai-Xia
2013-08-01
The research aimed at investigating the physicochemical properties, stability and skin penetration in vitro of total alkaloids of Sophora flavescens nanoemulsion. Prepare total alkaloids of S. flavescens nanoemulsion and detect the determination of matrine and oxymatrine in the nanoemulsion using HPLC method. Transmission electron microscopy and laser particle size analyzer were utilized to detect the shape and size of the nanoemulsion respectively. And also the stability of nanoemulsion was studied under the conditions of low temperature (4 degrees C), normal temperature (25 degrees C) and high temperature (60 degrees C). Franz diffusion cell was used to research the transdermal absorption of nanoemulsion in vitro. The results found that the nanoemulsion we prepared presented appearance of rounded, uniform; its average diameter was (15.55 +/- 2.24) nm, and particle size distribution value was 0. 161; the appearance, diameter and percentage determination of total alkaloids of S. flavescens had no variations after 15 d under 4, 25, 60 degrees C respectively. The steady-state permeation rate was 4.564 1 microg x cm(-2) x h(-1), 24 h cumulative amount of penetration was 110.7 microg x cm(-2), which was 1.86 fold of 24 h cumulative amount of aqueous solution (59.41 microg x cm(-2)). All the results demonstrated total alkaloids of S. flavescens nanoemulsion had good permeability, and could provide a new preparation for its clinical application.
NASA Astrophysics Data System (ADS)
Kereszturi, Akos
2012-11-01
Subsurface sampling will be important in the robotic exploration of Mars in the future, and this activity requires a somewhat different approach in landing site selection than earlier, surface analysis focused missions. In this work theoretical argumentation for the selection of ideal sites is summarized, including various parameters that were defined as examples for the earlier four candidate landing sites of Mars Science Laboratory. The aim here was to compare interesting sites; the decision on the final site does not affect this work. Analyzing the theoretical background, to identify ideal locations for subsurface analysis, several factors could be identified by remote sensing, including the dust and dune coverage, the cap layer distribution as well as the location of probable important outcrops. Beyond the fact that image based information on the rock hardness on Mars is lacking, more work would be also useful to put the interesting sites into global context and to understand the role of secondary cratering in age estimation. More laboratory work would be also necessary to improve our knowledge on the extraction and preservation of organic materials under different conditions. Beyond the theoretical argumentation mentioned above, the size and accessibility of possible important shallow subsurface materials were analyzed at the four earlier candidate landing sites of Mars Science Laboratory. At the sample terrains, interesting but inaccessible, interesting and sideward accessible, and interesting and from above accessible outcrops were identified. Surveying these outcrop types at the sample terrains, the currently available datasets showed only 3-9% of exposed strata over the entire analyzed area is present at Eberswalde and Holden crater, and individual outcrops have an average diameter between 100 and 400 m there. For Gale crater and Mawrth Valles region, these parameters were 46-35% of exposed strata, with an average outcrop diameter of ˜300 m. In the case of the first two sites smaller and elongated outcrops were present in larger number, while in the second group average sizes of outcrops were around 3000 m in diameter. The analysis suggests that for future missions aimed at subsurface sampling, different exploration strategies would be ideal at different terrains, and the target terrain's characteristics should be taken into account during the planning phase of the mission.
Horehledova, Barbora; Mihl, Casper; Hendriks, Babs M F; Eijsvoogel, Nienke G; Vainer, Jindrich; Veenstra, Leo F; Wildberger, Joachim E; Das, Marco
2018-06-16
Incorrect prosthesis size has direct impact on patient outcome after transcatheter aortic valve implantation (TAVI) procedure. Currently, annular diameter, area or perimeter may be used for prosthesis size selection. The aim was to evaluate whether the use different annular dimensions would result in the selection of different prosthesis sizes, when assessed in the same TAVI-candidate during the same phase of a cardiac cycle. Fifty consecutive TAVI-candidates underwent retrospectively ECG-gated computed tomography angiography (CTA). Aortic root dimensions were assessed in the 20% phase of the R-R interval. Annular short diameter, perimeter and area were used to select the prosthesis size, based on the industry recommendations for a self-expandable (Medtronic CoreValve; MCV) and balloon-expandable (Edwards Sapien XT Valve; ESV) valve. Complete agreement on selected prosthesis size amongst all three annular dimensions was observed in 62% (31/50; ESV) and 30% (15/50; MCV). Short aortic annulus measurement resulted in a smaller prosthesis size in 20% (10/50; ESV) and in 60% of cases (30/50; MCV) compared to the size suggested by both annular perimeter and area. In 18% (9/50; ESV) and 10% of cases (5/50; MCV) a larger prosthesis would have been selected based on annular perimeter compared to annular diameter and area. Prosthesis size derived from area was always in agreement with at least one other parameter in all cases. Aortic annulus area appears to be the most robust parameter for TAVI-prosthesis size selection, regardless of the specific prosthesis size. Short aortic annulus diameter may underestimate the prosthesis size, while use of annular perimeter may lead to size overestimation in some cases.
Skerl, K; Vinnicombe, S; Giannotti, E; Thomson, K; Evans, A
2015-12-01
To evaluate the influence of the region of interest (ROI) size and lesion diameter on the diagnostic performance of 2D shear wave elastography (SWE) of solid breast lesions. A study group of 206 consecutive patients (age range 21-92 years) with 210 solid breast lesions (70 benign, 140 malignant) who underwent core biopsy or surgical excision was evaluated. Lesions were divided into small (diameter <15 mm, n=112) and large lesions (diameter ≥15 mm, n=98). An ROI with a diameter of 1, 2, and 3 mm was positioned over the stiffest part of the lesion. The maximum elasticity (Emax), mean elasticity (Emean) and standard deviation (SD) for each ROI size were compared to the pathological outcome. Statistical analysis was undertaken using the chi-square test and receiver operating characteristic (ROC) analysis. The ROI size used has a significant impact on the performance of Emean and SD but not on Emax. Youden's indices show a correlation with the ROI size and lesion size: generally, the benign/malignant threshold is lower with increasing ROI size but higher with increasing lesion size. No single SWE parameter has superior performance. Lesion size and ROI size influence diagnostic performance. Copyright © 2015. Published by Elsevier Ltd.
The Attributes of a Variable-Diameter Rotor System Applied to Civil Tiltrotor Aircraft
NASA Technical Reports Server (NTRS)
Brender, Scott; Mark, Hans; Aguilera, Frank
1996-01-01
The attributes of a variable diameter rotor concept applied to civil tiltrotor aircraft are investigated using the V/STOL aircraft sizing and performance computer program (VASCOMP). To begin, civil tiltrotor viability issues that motivate advanced rotor designs are discussed. Current work on the variable diameter rotor and a theoretical basis for the advantages of the rotor system are presented. The size and performance of variable diameter and conventional tiltrotor designs for the same baseline mission are then calculated using a modified NASA Ames version of VASCOMP. The aircraft are compared based on gross weight, fuel required, engine size, and autorotative performance for various hover disk loading values. Conclusions about the viability of the resulting designs are presented and a program for further variable diameter rotor research is recommended.
Brain Arterial Diameters as a Risk Factor for Vascular Events.
Gutierrez, Jose; Cheung, Ken; Bagci, Ahmet; Rundek, Tatjana; Alperin, Noam; Sacco, Ralph L; Wright, Clinton B; Elkind, Mitchell S V
2015-08-06
Arterial luminal diameters are routinely used to assess for vascular disease. Although small diameters are typically considered pathological, arterial dilatation has also been associated with disease. We hypothesize that extreme arterial diameters are biomarkers of the risk of vascular events. Participants in the Northern Manhattan Study who had a time-of-flight magnetic resonance angiography were included in this analysis (N=1034). A global arterial Z-score, called the brain arterial remodeling (BAR) score, was obtained by averaging the measured diameters within each individual. Individuals with a BAR score <-2 SDs were considered to have the smallest diameters, individuals with a BAR score >-2 and <2 SDs had average diameters, and individuals with a BAR score >2 SDs had the largest diameters. All vascular events were recorded prospectively after the brain magnetic resonance imaging. Spline curves and incidence rates were used to test our hypothesis. The association of the BAR score with death (P=0.001), vascular death (P=0.02), any vascular event (P=0.05), and myocardial infarction (P=0.10) was U-shaped except for ischemic stroke (P=0.74). Consequently, incidence rates for death, vascular death, myocardial infarction, and any vascular event were higher in individuals with the largest diameters, whereas individuals with the smallest diameters had a higher incidence of death, vascular death, any vascular event, and ischemic stroke compared with individuals with average diameters. The risk of death, vascular death, and any vascular event increased at both extremes of brain arterial diameters. The pathophysiology linking brain arterial remodeling to systemic vascular events needs further research. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Encapsulation of nanoclusters in dried gel materials via an inverse micelle/sol gel synthesis
Martino, Anthony; Yamanaka, Stacey A.; Kawola, Jeffrey S.; Showalter, Steven K.; Loy, Douglas A.
1998-01-01
A dried gel material sterically entrapping nanoclusters of a catalytically active material and a process to make the material via an inverse micelle/sol-gel synthesis. A surfactant is mixed with an apolar solvent to form an inverse micelle solution. A salt of a catalytically active material, such as gold chloride, is added along with a silica gel precursor to the solution to form a mixture. To the mixture are then added a reducing agent for the purpose of reducing the gold in the gold chloride to atomic gold to form the nanoclusters and a condensing agent to form the gel which sterically entraps the nanoclusters. The nanoclusters are normally in the average size range of from 5-10 nm in diameter with a monodisperse size distribution.
Tolleson, M W; Gill, C A; Herring, A D; Riggs, P K; Sawyer, J E; Sanders, J O; Riley, D G
2017-06-01
The size, support, and health of udders limit the productive life of beef cows, especially those with background, because, in general, such cows have a reputation for problems with udders. Genomic association studies of bovine udder traits have been conducted in dairy cattle and recently in Continental European beef breeds but not in cows with background. The objective of this study was to determine associations of SNP and udder support scores, teat length, and teat diameter in half (Nellore), half (Angus) cows. Udders of cows ( = 295) born from 2003 to 2007 were evaluated for udder support and teat length and diameter ( = 1,746 records) from 2005 through 2014. These included a subjective score representing udder support (values of 1 indicated poorly supported, pendulous udders and values of 9 indicated very well-supported udders) and lengths and diameters of individual teats in the 4 udder quarters as well as the average. Cows were in full-sibling or half-sibling families. Residuals for each trait were produced from repeated records models with cow age category nested within birth year of cows. Those residuals were averaged to become the dependent variables for genomewide association analyses. Regression analyses of those dependent variables included genotypic values as explanatory variables for 34,980 SNP from a commercially available array and included the genomic relationship matrix. Fifteen SNP loci on BTA 5 were associated (false discovery rate controlled at 0.05) with udder support score. One of those was also detected as associated with average teat diameter. Three of those 15 SNP were located within genes, including one each in (), (), and (). These are notable for their functional role in some aspect of mammary gland formation or health. Other candidate genes for these traits in the vicinity of the SNP loci include () and (). Because these were detected in Nellore-Angus crossbred cows, which typically have very well-formed udders with excellent support across their productive lives, similar efforts in other breeds should be completed, because that may facilitate further refinement of genomic regions responsible for variation in udder traits important in multiple breeds.
Wagner, Till; Hupkens, Pieter; Slater, Nicholas J; Ulrich, Dietmar J O
2016-04-01
Coverage of soft-tissue defects of the knee due to multiple operations, trauma, and infection remains a surgical challenge. Often, these defects are repaired using free tissue transfer. The aim of this study was to find an easy and reliable local method of repair for small to medium-sized defects. The authors describe a new surgical option for tissue coverage using a proximally based long peroneal muscle turnover flap (LPTF) with split-thickness skin graft. Proximally based LPTFs were harvested and transposed into same-size created defects in five cadavers. After optimizing this technique, it was clinically used in two patients with defects secondary to total knee replacement revisions. Average cadaver flap size was 4.7 × 15.8 cm allowing reach of all knee joint areas and was based consistently on a sufficient (2-mm-diameter average) proximal arterial branch of the anterior tibial artery. Donor sites were closed without tension. Subsequent application of the flap on two patients resulted in good functional outcome. The proximally based LPTF is a new option available in the reconstruction of knee defects and should be added to the reconstructive surgeon's armamentarium of pedicled flaps, providing short operating time and promising clinical outcome. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Yanxiao; Xiang, Yongyuan; Erdélyi, Robertus; Liu, Zhong; Li, Dong; Ning, Zongjun; Bi, Yi; Wu, Ning; Lin, Jun
2018-03-01
Properties of photospheric bright points (BPs) near an active region have been studied in TiO λ 7058 Å images observed by the New Vacuum Solar Telescope of the Yunnan Observatories. We developed a novel recognition method that was used to identify and track 2010 BPs. The observed evolving BPs are classified into isolated (individual) and non-isolated (where multiple BPs are observed to display splitting and merging behaviors) sets. About 35.1% of BPs are non-isolated. For both isolated and non-isolated BPs, the brightness varies from 0.8 to 1.3 times the average background intensity and follows a Gaussian distribution. The lifetimes of BPs follow a log-normal distribution, with characteristic lifetimes of (267 ± 140) s and (421 ± 255) s, respectively. Their size also follows log-normal distribution, with an average size of about (2.15 ± 0.74) × 104 km2 and (3.00 ± 1.31) × 104 km2 for area, and (163 ± 27) km and (191 ± 40) km for diameter, respectively. Our results indicate that regions with strong background magnetic field have higher BP number density and higher BP area coverage than regions with weak background field. Apparently, the brightness/size of BPs does not depend on the background field. Lifetimes in regions with strong background magnetic field are shorter than those in regions with weak background field, on average.
Evidence for the formation of SiGe nanoparticles in Ge-implanted Si 3N 4
Mirzaei, S.; Kremer, F.; Feng, R.; ...
2017-03-14
SiGe nanoparticles were formed in an amorphous Si 3N 4 matrix by Ge + ion implantation and thermal annealing. The size of the nanoparticles was determined by transmission electron microscopy and their atomic structure by x-ray absorption spectroscopy. Nanoparticles were observed for excess Ge concentrations in the range from 9 to 12 at. % after annealing at temperatures in the range from 700 to 900 °C. The average nanoparticle size increased with excess Ge concentration and annealing temperature and varied from an average diameter of 1.8±0.2 nm for the lowest concentration and annealing temperature to 3.2±0.5 nm for the highestmore » concentration and annealing temperature. Our study demonstrates that the structural properties of embedded SiGe nanoparticles in amorphous Si 3N 4 are sensitive to the implantation and post implantation conditions. Furthermore, we demonstrate that ion implantation is a novel pathway to fabricate and control the SiGe nanoparticle structure and potentially useful for future optoelectronic device applications.« less
Napper, Imogen E; Thompson, Richard C
2016-11-15
Washing clothes made from synthetic materials has been identified as a potentially important source of microscopic fibres to the environment. This study examined the release of fibres from polyester, polyester-cotton blend and acrylic fabrics. These fabrics were laundered under various conditions of temperature, detergent and conditioner. Fibres from waste effluent were examined and the mass, abundance and fibre size compared between treatments. Average fibre size ranged between 11.9 and 17.7μm in diameter, and 5.0 and 7.8mm in length. Polyester-cotton fabric consistently shed significantly fewer fibres than either polyester or acrylic. However, fibre release varied according to wash treatment with various complex interactions. We estimate over 700,000 fibres could be released from an average 6kg wash load of acrylic fabric. As fibres have been reported in effluent from sewage treatment plants, our data indicates fibres released by washing of clothing could be an important source of microplastics to aquatic habitats. Copyright © 2016 Elsevier Ltd. All rights reserved.
Rapid extra-/intracellular biosynthesis of gold nanoparticles by the fungus Penicillium sp.
NASA Astrophysics Data System (ADS)
Du, Liangwei; Xian, Liang; Feng, Jia-Xun
2011-03-01
In this work, the fungus Penicillium was used for rapid extra-/intracellular biosynthesis of gold nanoparticles. AuCl4 - ions reacted with the cell filtrate of Penicillium sp. resulting in extracellular biosynthesis of gold nanoparticles within 1 min. Intracellular biosynthesis of gold nanoparticles was obtained by incubating AuCl4 - solution with fungal biomass for 8 h. The gold nanoparticles were characterized by means of visual observation, UV-Vis absorption spectroscopy, X-ray diffraction (XRD), transmission electron microscopy (TEM), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDX). The extracellular nanoparticles exhibited maximum absorbance at 545 nm in UV-Vis spectroscopy. The XRD spectrum showed Bragg reflections corresponding to the gold nanocrystals. TEM exhibited the formed spherical gold nanoparticles in the size range from 30 to 50 nm with an average size of 45 nm. SEM and TEM revealed that the intracellular gold nanoparticles were well dispersed on the cell wall and within the cell, and they are mostly spherical in shape with an average diameter of 50 nm. The presence of gold was confirmed by EDX analysis.
Yang, Xiupei; Su, Yan; Paau, Man Chin; Choi, Martin M F
2012-02-07
This paper presents a simple and convenient methodology to separate and characterize water-soluble gold nanocluster stabilized with penicillamine ligands (AuNC-SR) in aqueous medium by sequential size-selective precipitation (SSSP) and mass spectrometry (MS). The highly polydisperse crude AuNC-SR product with an average core diameter of 2.1 nm was initially synthesized by a one-phase solution method. AuNCs were then precipitated and separated successively from larger to smaller ones by progressively increasing the concentration of acetone in the aqueous AuNCs solution. The SSSP fractions were analyzed by UV-vis spectroscopy, matrix-assisted laser desorption/ionization time-of-flight-MS, and thermogravimetric analysis (TGA). The MS and TGA data confirmed that the fractions precipitated from 36, 54, 72, and 90% v/v acetone (F(36%), F(54%), F(72%), and F(90%)) comprised families of close core size AuNCs with average molecular formulas of Au(38)(SR)(18), Au(28)(SR)(15), Au(18)(SR)(12), and Au(11)(SR)(8), respectively. In addition, F(36%), F(54%), F(72%), and F(90%) contained also the typical magic-sized gold nanoparticles of Au(38), Au(25), Au(18), and Au(11), respectively, together with some other AuNCs. This study shed light on the potential use of SSSP for simple and large-scale preliminary separation of polydisperse water-soluble AuNCs into different fractions with a relatively narrower size distribution. © 2012 American Chemical Society
1990-01-01
Uncuffed Endotracheal Tube Size, the Diameter of the Distal Digit of the Little Finger and the Penlington Formula 12. PERSONAL AUTHOR(S) Roy H. Fukuoka 13a...BETWEEN ACTUAL UNCUFFED ENDOTRACHEAL TUBE SIZE, THE DIAMETER OF THE DISTAL DIGIT OF THE LITTLE FINGER AND THE PENLINGTON FORMULA By Roy H. Fukuoka May... PENLINGTON FORMULA A THESIS PROPOSAL Presented to the Department of Nursing California State University, Long Beach In Partial Fulfillment of the
Indirect and direct methods for measuring a dynamic throat diameter in a solid rocket motor
NASA Astrophysics Data System (ADS)
Colbaugh, Lauren
In a solid rocket motor, nozzle throat erosion is dictated by propellant composition, throat material properties, and operating conditions. Throat erosion has a significant effect on motor performance, so it must be accurately characterized to produce a good motor design. In order to correlate throat erosion rate to other parameters, it is first necessary to know what the throat diameter is throughout a motor burn. Thus, an indirect method and a direct method for determining throat diameter in a solid rocket motor are investigated in this thesis. The indirect method looks at the use of pressure and thrust data to solve for throat diameter as a function of time. The indirect method's proof of concept was shown by the good agreement between the ballistics model and the test data from a static motor firing. The ballistics model was within 10% of all measured and calculated performance parameters (e.g. average pressure, specific impulse, maximum thrust, etc.) for tests with throat erosion and within 6% of all measured and calculated performance parameters for tests without throat erosion. The direct method involves the use of x-rays to directly observe a simulated nozzle throat erode in a dynamic environment; this is achieved with a dynamic calibration standard. An image processing algorithm is developed for extracting the diameter dimensions from the x-ray intensity digital images. Static and dynamic tests were conducted. The measured diameter was compared to the known diameter in the calibration standard. All dynamic test results were within +6% / -7% of the actual diameter. Part of the edge detection method consists of dividing the entire x-ray image by an average pixel value, calculated from a set of pixels in the x-ray image. It was found that the accuracy of the edge detection method depends upon the selection of the average pixel value area and subsequently the average pixel value. An average pixel value sensitivity analysis is presented. Both the indirect method and the direct method prove to be viable approaches to determining throat diameter during solid rocket motor operation.
PHYSICAL PROPERTIES OF LARGE AND SMALL GRANULES IN SOLAR QUIET REGIONS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu Daren; Xie Zongxia; Hu Qinghua
The normal mode observations of seven quiet regions obtained by the Hinode spacecraft are analyzed to study the physical properties of granules. An artificial intelligence technique is introduced to automatically find the spatial distribution of granules in feature spaces. In this work, we investigate the dependence of granular continuum intensity, mean Doppler velocity, and magnetic fields on granular diameter. We recognized 71,538 granules by an automatic segmentation technique and then extracted five properties: diameter, continuum intensity, Doppler velocity, and longitudinal and transverse magnetic flux density to describe the granules. To automatically explore the intrinsic structures of the granules in themore » five-dimensional parameter space, the X-means clustering algorithm and one-rule classifier are introduced to define the rules for classifying the granules. It is found that diameter is a dominating parameter in classifying the granules and two families of granules are derived: small granules with diameters smaller than 1.''44, and large granules with diameters larger than 1.''44. Based on statistical analysis of the detected granules, the following results are derived: (1) the averages of diameter, continuum intensity, and Doppler velocity in the upward direction of large granules are larger than those of small granules; (2) the averages of absolute longitudinal, transverse, and unsigned flux density of large granules are smaller than those of small granules; (3) for small granules, the average of continuum intensity increases with their diameters, while the averages of Doppler velocity, transverse, absolute longitudinal, and unsigned magnetic flux density decrease with their diameters. However, the mean properties of large granules are stable; (4) the intensity distributions of all granules and small granules do not satisfy Gaussian distribution, while that of large granules almost agrees with normal distribution with a peak at 1.04 I{sub 0}.« less
Sivakami, R; Dhanuskodi, S; Karvembu, R
2016-01-05
RuO2 nanoparticles (RuO2 NPs) have been successfully synthesized by the hydrothermal method. Structure and the particle size have been determined by X-ray diffraction (XRD), scanning electron microscopy (SEM), atomic force microscopy (AFM) and transmission electron microscopy (TEM). UV-Vis spectra reveal that the optical band gap of RuO2 nanoparticles is red shifted from 3.95 to 3.55eV. BET measurements show a high specific surface area (SSA) of 118-133m(2)/g and pore diameter (10-25nm) has been estimated by Barret-Joyner-Halenda (BJH) method. The crystallite size and lattice strain in the samples have been investigated by Williamson-Hall (W-H) analysis assuming uniform deformation, deformation stress and deformation energy density, and the size-strain plot method. All other relevant physical parameters including stress, strain and energy density have been calculated. The average crystallite size and the lattice strain evaluated from XRD measurements are in good agreement with the results of TEM. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Jonas, A. M.; Legras, R.; Ferain, E.
1998-03-01
Nanoporous track-etched membranes with narrow pore size distributions and average pore size diameters tunable from 100 to 1000 Åare produced by the chemical etching of latent tracks in polymer films after irradiation by a beam of accelerated heavy ions. Nanoporous membranes are used for highly demanding filtration purposes, or as templates to obtain metallic or polymeric nanowires (L. Piraux et al., Nucl. Instr. Meth. Phys. Res. 1997, B131, 357). Such applications call for developments in nanopore size characterization techniques. In this respect, we report on the characterization by small-angle X-ray scattering (SAXS) of nanopore size distribution (nPSD) in polycarbonate track-etched membranes. The obtention of nPSD requires inverting an ill-conditioned inhomogeneous equation. We present different numerical routes to overcome the amplification of experimental errors in the resulting solutions, including a regularization technique allowing to obtain the nPSD without a priori knowledge of its shape. The effect of deviations from cylindrical pore shape on the resulting distributions are analyzed. Finally, SAXS results are compared to results obtained by electron microscopy and conductometry.
Properties and evolution of NEO families created by tidal disruption at Earth
NASA Astrophysics Data System (ADS)
Schunová, Eva; Jedicke, Robert; Walsh, Kevin J.; Granvik, Mikael; Wainscoat, Richard J.; Haghighipour, Nader
2014-08-01
We have calculated the coherence and detectable lifetimes of synthetic near-Earth object (NEO) families created by catastrophic disruption of a progenitor as it suffers a very close Earth approach. The closest or slowest approaches yield the most violent ‘s-class’ disruption events where the largest remaining fragment after disruption and reaccumulation retains less than 50% of the parent’s mass. The resulting fragments have a ‘string of pearls’ configuration after their reaccummulation into gravitationally bound components (Richardson, D.C., Bottke, W.F., Love, S.G. [1998]. Icarus 134, 47-76). We found that the average absolute magnitude (H) difference between the parent body and the largest fragment is ΔH∼1.0. The average slope of the absolute magnitude (H) distribution, N(H)∝10, for the fragments in the s-class families is steeper than the slope of the NEO population (Mainzer, A., et al. [2011]. Astrophys. J. 743, 156) in the same size range. The es remain coherent as statistically significant clusters of orbits within the NEO population for an average of τbarc=(14.7±0.6)×103 yr after disruption. The detectable lifetimes of tidally disrupted families are extremely short compared to the multi-Myr and -Gyr lifetimes of main belt families due to the chaotic dynamical environment in NEO space-they are detectable with the techniques developed by Fu et al. and Schunová et al. (Fu, H., Jedicke, R., Durda, D.D., Fevig, R., Binzel, R.P. [2005]. Icarus 178(2), 434-449 and Schunová, E., Granvik, M., Jedicke, R., Gronchi, G., Wainscoat, R., Abe, S. [2012]. Icarus 220, 1050-1063) for an average duration (τbardet) ranging from about 2000 to about 12,000 years for progenitors in the absolute magnitude (Hp) range from 20 to 13 corresponding to diameters in the range from about 0.5 to 10 km respectively. The maximum absolute magnitude of a progenitor capable of producing an observable NEO family (i.e. detectable by our family finding technique) is Hp,max=20 (about 350 m diameter). The short detectability lifetime explains why zero NEO families have been discovered to-date. Nonetheless, every tidal disruption event of a progenitor with diameter greater than 0.5 km is capable of producing several million fragments in the 1-10 m diameter range that can contribute to temporary local density enhancements of small NEOs in Earth’s vicinity. We expect that there are about 1200 objects in the steady state NEO population in this size range due to tidal disruption assuming that one 1 km diameter NEO tidally disrupts at Earth every 2500 years. These objects may be suitable targets for asteroid retrieval missions due to their Earth-like orbits with corresponding low v∞ which permits low-cost missions. The fragments from the tidal disruptions evolve into orbits that bring them into collision with terrestrial planets or the Sun or they may be ejected from the Solar System on hyperbolic orbits due to deep planetary encounters. The end-state for the fragments from a tidal disruption at Earth have ∼5× the collision probability with Earth compared to the background NEO population.
Benjamin O. Knapp; G. Geoff Wang; David H. Van Lear; Joan L. Walker
2006-01-01
The size, especially the root size, of advance oak (Quercus spp.) reproduction provides the best indication of the growth potential after release or top-kill. This study examined the relationship between the size of the root system and various diameter height measurements for small (
Primary and Aggregate Size Distributions of PM in Tail Pipe Emissions form Diesel Engines
NASA Astrophysics Data System (ADS)
Arai, Masataka; Amagai, Kenji; Nakaji, Takayuki; Hayashi, Shinji
Particulate matter (PM) emission exhausted from diesel engine should be reduced to keep the clean air environment. PM emission was considered that it consisted of coarse and aggregate particles, and nuclei-mode particles of which diameter was less than 50nm. However the detail characteristics about these particles of the PM were still unknown and they were needed for more physically accurate measurement and more effective reduction of exhaust PM emission. In this study, the size distributions of solid particles in PM emission were reported. PMs in the tail-pipe emission were sampled from three type diesel engines. Sampled PM was chemically treated to separate the solid carbon fraction from other fractions such as soluble organic fraction (SOF). The electron microscopic and optical-manual size measurement procedures were used to determine the size distribution of primary particles those were formed through coagulation process from nuclei-mode particles and consisted in aggregate particles. The centrifugal sedimentation method was applied to measure the Stokes diameter of dry-soot. Aerodynamic diameters of nano and aggregate particles were measured with scanning mobility particle sizer (SMPS). The peak aggregate diameters detected by SMPS were fallen in the same size regime as the Stokes diameter of dry-soot. Both of primary and Stokes diameters of dry-soot decreased with increases of engine speed and excess air ratio. Also, the effects of fuel properties and engine types on primary and aggregate particle diameters were discussed.
[Size-based classification of choroidal melanoma and its role in treatment decision-making].
Brovkina, A F; Stoyukhina, A S; Chesalin, I P
2016-01-01
To specify indications for brachytherapy (BT) in large choroidal melanoma (CM) so that tumor size and vital prognosis were considered. We retrospectively analyzed data from 161 CM patients who were treated with BT and followed-up at either the Ophthalmological Clinical Hospital or some other Moscow medical facility and also registered by the City Cancer Registry. Patient age at the time of starting the treatment lied within the range of 17 to 84 years and averaged 56.89±1.93 years. During the follow-up period (12-275 months, 95.65±8.4 months on average) hematogenous metastases were found in 23 (14.29%) patients. Liver involvement was diagnosed in 8 patients within the average of 23.13 months after treatment. Their average survival time was 11 months. A total of 142 patients were followed up for more than 36 months (104.87 months on average). Of them, 15 patients were diagnosed with metastatic CM within 37-167 months after BT (80.27 months on average). Despite metastatic disease they generally survived 2.8 time longer than the aforementioned patients (30.8 months). The cases were then divided into 3 groups according to J. Shields classification of CM. Small melanoma patients did not develop metastases within 99.96±12.47 months of follow-up. In medium melanomas, as many as 13.35% of cases were metastatic (with the average survival time of 20.66 months); in large melanomas - 19.51% (with the average survival time of 13.5 months). Treatment modality and follow-up periods being the same (7-8 years after BT), larger choroidal melanomas has been shown to be associated with higher risk of hematogenous metastases. For local treatment to be successive, the maximal diameter of the tumor should not exceed 10 mm. Every fifth patient of those with CM larger than 15 mm is likely to develop hematogenous metastases. The results obtained indicate the necessity of decreasing the size thresholds for choroidal melanomas, small and medium in the first place.
Bed material transport in the Virgin River, Utah
Andrews, E.D.
2000-01-01
Detailed information concerning the rate and particle size distribution of bed material transport by streamflows can be very difficult and expensive to obtain, especially where peak streamflows are brief and bed material is poorly sorted, including some very large boulders. Such streams, however, are common in steep, arid watersheds. Any computational approach must consider that (1) only the smaller particle sizes present on the streambed move even during large floods and (2) the largest bed particles exert a significant form drag on the flow. Conventional methods that rely on a single particle size to estimate the skin friction shear stress acting on the mobile fraction of the bed material perform poorly. Instead, for this study, the skin friction shear stress was calculated for the observed range of streamflows by calculating the form drag exerted on the reach‐averaged flow field by all particle sizes. Suspended and bed load transported rates computed from reach‐averaged skin friction shear stress are in excellent agreement with measured transport rates. The computed mean annual bed material load, including both bed load and suspended load, of the East Fork Virgin River for the water years 1992‐1996 was approximately 1.3×10 5 t. A large portion of the bed material load consists of sand‐sized particles, 0.062–1.0 mm in diameter, that are transported in suspension. Such particles, however, constituted only 10% of the surface bed material and less than 25% of the subsurface bed material. The mean annual quantity of bed load transported was 1060 t/yr with a median size of 15 mm.
NASA Astrophysics Data System (ADS)
Yamada, Hironori; Ujiie, Hiroto; Urata, Chihiro; Yamamoto, Eisuke; Yamauchi, Yusuke; Kuroda, Kazuyuki
2015-11-01
Both the pore size and particle diameter of aqueous colloidal mesostructured/mesoporous silica nanoparticles (CMSS/CMPS) derived from tetrapropoxysilane were effectively and easily controlled by the addition of trialkylbenzenes (TAB). Aqueous highly dispersed CMPS with large pores were successfully obtained through removal of surfactants and TAB by a dialysis process. The pore size (from 4 nm to 8 nm) and particle diameter (from 50 nm to 380 nm) were more effectively enlarged by the addition of 1,3,5-triisopropylbenzene (TIPB) than 1,3,5-trimethylbenzene (TMB), and the enlargement did not cause the variation of the mesostructure and particle morphology. The larger molecular size and higher hydrophobicity of TIPB than TMB induce the incorporation of TIPB into micelles without the structural change. When TMB was used as TAB, the pore size of CMSS was also enlarged while the mesostructure and particle morphology were varied. Interestingly, when tetramethoxysilane and TIPB were used, CMSS with a very small particle diameter (20 nm) with concave surfaces and large mesopores were obtained, which may strongly be related to the initial nucleation of CMSS. A judicious choice of TAB and Si sources is quite important to control the mesostructure, size of mesopores, particle diameter, and morphology.Both the pore size and particle diameter of aqueous colloidal mesostructured/mesoporous silica nanoparticles (CMSS/CMPS) derived from tetrapropoxysilane were effectively and easily controlled by the addition of trialkylbenzenes (TAB). Aqueous highly dispersed CMPS with large pores were successfully obtained through removal of surfactants and TAB by a dialysis process. The pore size (from 4 nm to 8 nm) and particle diameter (from 50 nm to 380 nm) were more effectively enlarged by the addition of 1,3,5-triisopropylbenzene (TIPB) than 1,3,5-trimethylbenzene (TMB), and the enlargement did not cause the variation of the mesostructure and particle morphology. The larger molecular size and higher hydrophobicity of TIPB than TMB induce the incorporation of TIPB into micelles without the structural change. When TMB was used as TAB, the pore size of CMSS was also enlarged while the mesostructure and particle morphology were varied. Interestingly, when tetramethoxysilane and TIPB were used, CMSS with a very small particle diameter (20 nm) with concave surfaces and large mesopores were obtained, which may strongly be related to the initial nucleation of CMSS. A judicious choice of TAB and Si sources is quite important to control the mesostructure, size of mesopores, particle diameter, and morphology. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr04465k
The use of mini-samples in palaeomagnetism
NASA Astrophysics Data System (ADS)
Böhnel, Harald; Michalk, Daniel; Nowaczyk, Norbert; Naranjo, Gildardo Gonzalez
2009-10-01
Rock cores of ~25 mm diameter are widely used in palaeomagnetism. Occasionally smaller diameters have been used as well which represents distinct advantages in terms of throughput, weight of equipment and core collections. How their orientation precision compares to 25 mm cores, however, has not been evaluated in detail before. Here we compare the site mean directions and their statistical parameters for 12 lava flows sampled with 25 mm cores (standard samples, typically 8 cores per site) and with 12 mm drill cores (mini-samples, typically 14 cores per site). The site-mean directions for both sample sizes appear to be indistinguishable in most cases. For the mini-samples, site dispersion parameters k on average are slightly lower than for the standard samples reflecting their larger orienting and measurement errors. Applying the Wilcoxon signed-rank test the probability that k or α95 have the same distribution for both sizes is acceptable only at the 17.4 or 66.3 per cent level, respectively. The larger mini-core numbers per site appears to outweigh the lower k values yielding also slightly smaller confidence limits α95. Further, both k and α95 are less variable for mini-samples than for standard size samples. This is interpreted also to result from the larger number of mini-samples per site, which better averages out the detrimental effect of undetected abnormal remanence directions. Sampling of volcanic rocks with mini-samples therefore does not present a disadvantage in terms of the overall obtainable uncertainty of site mean directions. Apart from this, mini-samples do present clear advantages during the field work, as about twice the number of drill cores can be recovered compared to 25 mm cores, and the sampled rock unit is then more widely covered, which reduces the contribution of natural random errors produced, for example, by fractures, cooling joints, and palaeofield inhomogeneities. Mini-samples may be processed faster in the laboratory, which is of particular advantage when carrying out palaeointensity experiments.
Giantism and its role in the harmful algal bloom species Phaeocystis globosa
NASA Astrophysics Data System (ADS)
Smith, Walker O.; Liu, Xiao; Tang, Kam W.; DeLizo, Liza M.; Doan, Nhu Hai; Nguyen, Ngoc Lam; Wang, Xiaodong
2014-03-01
The cosmopolitan alga Phaeocystis globosa forms large blooms in shallow coastal waters off the Viet Nam coast, which impacts the local aquaculture and fishing industries substantially. The unusual feature of this alga is that it forms giant colonies that can reach up to 3 cm in diameter. We conducted experiments designed to elucidate the ecophysiological characteristics that presumably favor the development of giant colonies. Satellite images of chlorophyll fluorescence showed that the coastal bloom was initiated in summer and temporally coincident with the onset of monsoonally driven upwelling. While determining the spatial distribution of Phaeocystis was not feasible, we sampled it in the near-shore region. A positive relationship was found between colony size and colonial cell densities, in contrast to results from the North Sea. Mean chlorophyll a concentration per cell was 0.45 pg cell-1, lower than in laboratory or temperate systems. The contribution of mucous carbon ranged from 63-95% of the total carbon; furthermore, mucous carbon per unit of colony surface area appeared to decrease with colony size, suggesting that the mucoid sheath became thinner as colonies grew larger. Sinking rates averaged 189 m d-1, strongly suggesting that giant colonies could only persist in shallow, turbulent environments. No relationship between colony size and sinking rates was observed. DOC concentrations of intracolonial fluid averaged 5940 μM, 25 times greater than ambient concentrations. Estimated diffusion coefficients of ions across the mucous envelope were ca. 1.0±0.3×10-7 cm2 s-1 for colonies with diameters of ca. 1.0 cm. In total, the characteristics of the giant colonies suggest that the Vietnamese strain is substantially different from that found in temperate environments, and that it has a number of unusual features that influence its growth and development in coastal Vietnamese waters.
Collagen fibril arrangement and size distribution in monkey oral mucosa
OTTANI, V.; FRANCHI, M.; DE PASQUALE, V.; LEONARDI, L.; MOROCUTTI, M.; RUGGERI, A.
1998-01-01
Collagen fibre organisation and fibril size were studied in the buccal gingival and hard palate mucosa of Macacus rhesus monkey. Light and electron microscopy analysis showed connective papillae exhibiting a similar inner structure in the different areas examined, but varying in distribution, shape and size. Moving from the deep to surface layers of the buccal gingival mucosa (free and attached portions), large collagen fibril bundles became smaller and progressively more wavy with decreasing collagen fibril diameter. This gradual diameter decrease did not occur in the hard palate mucosa (free portion, rugae and interrugal regions) where the fibril diameter remained constant. A link between collagen fibril diameter and mechanical function is discussed. PMID:9688498
Ultrafine particles and nitrogen oxides generated by gas and electric cooking.
Dennekamp, M; Howarth, S; Dick, C A; Cherrie, J W; Donaldson, K; Seaton, A
2001-08-01
To measure the concentrations of particles less than 100 nm diameter and of oxides of nitrogen generated by cooking with gas and electricity, to comment on possible hazards to health in poorly ventilated kitchens. Experiments with gas and electric rings, grills, and ovens were used to compare different cooking procedures. Nitrogen oxides (NO(x)) were measured by a chemiluminescent ML9841A NO(x) analyser. A TSI 3934 scanning mobility particle sizer was used to measure average number concentration and size distribution of aerosols in the size range 10-500 nm. High concentrations of particles are generated by gas combustion, by frying, and by cooking of fatty foods. Electric rings and grills may also generate particles from their surfaces. In experiments where gas burning was the most important source of particles, most particles were in the size range 15-40 nm. When bacon was fried on the gas or electric rings the particles were of larger diameter, in the size range 50-100 nm. The smaller particles generated during experiments grew in size with time because of coagulation. Substantial concentrations of NO(X) were generated during cooking on gas; four rings for 15 minutes produced 5 minute peaks of about 1000 ppb nitrogen dioxide and about 2000 ppb nitric oxide. Cooking in a poorly ventilated kitchen may give rise to potentially toxic concentrations of numbers of particles. Very high concentrations of oxides of nitrogen may also be generated by gas cooking, and with no extraction and poor ventilation, may reach concentrations at which adverse health effects may be expected. Although respiratory effects of exposure to NO(x) might be anticipated, recent epidemiology suggests that cardiac effects cannot be excluded, and further investigation of this is desirable.
Kero, Ida; Naess, Mari K.; Tranell, Gabriella
2015-01-01
The present article presents a comprehensive evaluation of the potential use of an Electrical Low Pressure Impactor (ELPI) in the ferroalloy industry with respect to indoor air quality and fugitive emission control. The ELPI was used to assess particulate emission properties, particularly of the fine particles (Dp ≤ 1 μm), which in turn may enable more satisfactory risk assessments for the indoor working conditions in the ferroalloy industry. An ELPI has been applied to characterize the fume in two different ferroalloy plants, one producing silicomanganese (SiMn) alloys and one producing ferrosilicon (FeSi) alloys. The impactor classifies the particles according to their aerodynamic diameter and gives real-time particle size distributions (PSD). The PSD based on both number and mass concentrations are shown and compared. Collected particles have also been analyzed by transmission and scanning electron microscopy with energy dispersive spectroscopy. From the ELPI classification, particle size distributions in the range 7 nm – 10 μm have been established for industrial SiMn and FeSi fumes. Due to the extremely low masses of the ultrafine particles, the number and mass concentration PSD are significantly different. The average aerodynamic diameters for the FeSi and the SiMn fume particles were 0.17 and 0.10 μm, respectively. Based on this work, the ELPI is identified as a valuable tool for the evaluation of airborne particulate matter in the indoor air of metallurgical production sites. The method is well suited for real-time assessment of morphology (particle shape), particle size, and particle size distribution of aerosols. PMID:25380385
NASA Astrophysics Data System (ADS)
Diesch, J.-M.; Drewnick, F.; Klimach, T.; Borrmann, S.
2012-08-01
Measurements of the ambient aerosol, various trace gases and meteorological parameters using a mobile laboratory (MoLa) were performed on the banks of the Lower Elbe in an emission control area (ECA) which is passed by numerous private and commercial marine vessels reaching and leaving the port of Hamburg, Germany. From 25-30 April 2011 a total of 178 vessels were probed at a distance of about 0.8-2 km with high temporal resolution. 139 ship emission plumes were of sufficient quality to be analyzed further and to determine emission factors (EFs). Concentrations of aerosol number and mass as well as polycyclic aromatic hydrocarbons (PAH) and black carbon were measured in PM1 and size distribution instruments covered the size diameter range from 6 nm up to 32 μm. The chemical composition of the non-refractory submicron aerosol was measured by means of an Aerosol Mass Spectrometer (Aerodyne HR-ToF-AMS). Gas phase species analyzers monitored various trace gases (O3, SO2, NO, NO2, CO2) in the air and a weather station provided wind, precipitation, solar radiation and other parameters. Together with ship information for each vessel obtained from Automatic Identification System (AIS) broadcasts a detailed characterization of the individual ship types and of features affecting gas and particulate emissions is provided. Particle number EFs (average 2.6×1016 # kg -1) and PM1 mass EFs (average 2.4 g kg -1) positively correlate with the fuel sulfur content and depend on the engine type and performance. Observed PM1 composition of the vessel emissions was dominated by organic matter (72%), sulfate (22%) and black carbon (6%) while PAHs only account for 0.2% of the submicron aerosol mass. Measurements of gaseous components showed an increase of SO2 (average EF: 7.7 g kg-1) and NOx (average EF: 53 g kg-1) while O3 decreased when a ship plume reached the sampling site. The particle number size distributions of the vessels are generally characterized by a bimodal size distribution, with the nucleation mode in the 10-20 nm diameter range and a combustion aerosol mode centered at about 35 nm while particles >1 μm were not found. "High particle number emitters" are characterized by a dominant nucleation mode. By contrast, a third weaker mode at 150 nm primarily occurred for "high black carbon emitters". Classifying the vessels according to their gross tonnage shows a decrease of the number, black carbon and PAH EFs while EFs of SO2, NO, NO2, NOx, AMS species (particulate organics, sulfate) and PM1 mass concentration increase with increasing gross tonnages.
Status and trends of bottomland hardwood forests in the mid-Atlantic Region
Anita Rose; Steve Meadows
2016-01-01
Bottomland hardwood forests cover approximately 2.9 million acres of the Coastal Plain and Piedmont region of Virginia and North Carolina. As of 2014, 59 percent of bottomland hardwood forests were in the large-diameter stand-size class. Between 2002 and 2014, area of large-diameter sized stands increased, while that of medium- and small-diameter stands decreased,...
Morphology of the Physiological Apical Foramen in Maxillary and Mandibular First Molars
Abarca, J.; Zaror, C.; Monardes, H.; Hermosilla, V.; Muñoz, C.; Cantin, M.
2015-01-01
SUMMARY Information regarding the anatomy of the physiological apical foramen is limited. Knowing its diameter and shapes contributes to clinical work, specifically to the cleaning and shaping of the apical third. The aim of this ex vivo study was to determine the minimum and maximum diameters and shape of the physiological apical foramen in the roots of maxillary and mandibular first molars. A descriptive study was conducted on 89 recently extracted first molars. Roots 3–5 mm from the apex were sectioned and prepared for analysis at 40× magnification. The minimum and maximum diameters of each physiological foramen were measured using the program Motic Images plus 2.0 ML. The shape of the foramina, classified as round, oval or irregular, was determined by the difference between the maximum and minimum diameters. A total of 174 physiological foramina were analyzed. The average of the minimum and maximum diameters was between 0.24–0.33 mm in maxillary first molars and between 0.25–0.33 mm in mandibular first molars. In maxillary molars, the most common shape of the foramen was oval (50%), then irregular (32%), then round (18%). In mandibular molars, the oval shape was also the most frequent (59%), followed by irregular (23%) and round (18%). The findings of this study regarding the morphology of physiological apical foramina in first molars make it easier for the operator to choose the appropriately-sized instruments to perform endodontic therapy successfully. PMID:25937698
Morphology of the Physiological Apical Foramen in Maxillary and Mandibular First Molars.
Abarca, J; Zaror, C; Monardes, H; Hermosilla, V; Muñoz, C; Cantin, M
2014-06-01
Information regarding the anatomy of the physiological apical foramen is limited. Knowing its diameter and shapes contributes to clinical work, specifically to the cleaning and shaping of the apical third. The aim of this ex vivo study was to determine the minimum and maximum diameters and shape of the physiological apical foramen in the roots of maxillary and mandibular first molars. A descriptive study was conducted on 89 recently extracted first molars. Roots 3-5 mm from the apex were sectioned and prepared for analysis at 40× magnification. The minimum and maximum diameters of each physiological foramen were measured using the program Motic Images plus 2.0 ML. The shape of the foramina, classified as round, oval or irregular, was determined by the difference between the maximum and minimum diameters. A total of 174 physiological foramina were analyzed. The average of the minimum and maximum diameters was between 0.24-0.33 mm in maxillary first molars and between 0.25-0.33 mm in mandibular first molars. In maxillary molars, the most common shape of the foramen was oval (50%), then irregular (32%), then round (18%). In mandibular molars, the oval shape was also the most frequent (59%), followed by irregular (23%) and round (18%). The findings of this study regarding the morphology of physiological apical foramina in first molars make it easier for the operator to choose the appropriately-sized instruments to perform endodontic therapy successfully.
Experimental strategies for imaging bioparticles with femtosecond hard X-ray pulses
Daurer, Benedikt J.; Okamoto, Kenta; Bielecki, Johan; ...
2017-04-07
This study explores the capabilities of the Coherent X-ray Imaging Instrument at the Linac Coherent Light Source to image small biological samples. The weak signal from small samples puts a significant demand on the experiment. AerosolizedOmono River virusparticles of ~40 nm in diameter were injected into the submicrometre X-ray focus at a reduced pressure. Diffraction patterns were recorded on two area detectors. The statistical nature of the measurements from many individual particles provided information about the intensity profile of the X-ray beam, phase variations in the wavefront and the size distribution of the injected particles. The results point to amore » wider than expected size distribution (from ~35 to ~300 nm in diameter). This is likely to be owing to nonvolatile contaminants from larger droplets during aerosolization and droplet evaporation. The results suggest that the concentration of nonvolatile contaminants and the ratio between the volumes of the initial droplet and the sample particles is critical in such studies. The maximum beam intensity in the focus was found to be 1.9 × 10 12photons per µm 2per pulse. The full-width of the focus at half-maximum was estimated to be 500 nm (assuming 20% beamline transmission), and this width is larger than expected. Under these conditions, the diffraction signal from a sample-sized particle remained above the average background to a resolution of 4.25 nm. Finally, the results suggest that reducing the size of the initial droplets during aerosolization is necessary to bring small particles into the scope of detailed structural studies with X-ray lasers.« less
NASA Astrophysics Data System (ADS)
Wassenaar, R. W.; Beanlands, R. S. B.; deKemp, R. A.
2004-02-01
Limited scanner resolution and cardiac motion contribute to partial volume (PV) averaging of cardiac PET images. An extravascular (EV) density image, created from the subtraction of a blood pool scan from a transmission image, has been used to correct for PV averaging in H/sub 2//sup 15/O studies using 2-D imaging but not with 3-D imaging of other tracers such as /sup 18/FDG. A cardiac phantom emulating the left ventricle was used to characterize the method for use in 3-D PET studies. Measurement of the average myocardial activity showed PV losses of 32% below the true activity (p<0.001). Initial application of the EV density correction still yielded a myocardial activity 13% below the true value (p<0.001). This failure of the EV density image was due to the 1.66 mm thick plastic barrier separating the myocardial and ventricular chambers within the phantom. Upon removal of this artifact by morphological dilation of the blood pool, the corrected myocardial value was within 2% of the true value (p=ns). Spherical ROIs (diameter of 2 to 10 mm), evenly distributed about the myocardium, were also used to calculate the average activity. The EV density image was able to account for PV averaging throughout the range of diameters to within a 5% accuracy, however, a small bias was seen as the size of the ROIs increased. This indicated a slight mismatch between the emission and transmission image resolutions, a result of the difference in data acquisitions (i.e., span and ring difference) and default smoothing. These results show that the use of EV density image to correct for PV averaging is possible with 3-D PET. A method of correcting barrier effects in phantoms has been presented, as well as a process for evaluating resolution mismatch.
Bernstein, Eric F; Civiok, Jennifer M
2013-12-01
Laser beam diameter affects the depth of laser penetration. Q-switched lasers tend to have smaller maximum spot sizes than other dermatologic lasers, making beam diameter a potentially more significant factor in treatment outcomes. To compare the clinical effect of using the maximum-size treatment beam available for each delivered fluence during laser tattoo removal to a standard 4-mm-diameter treatment beam. Thirteen tattoos were treated in 12 subjects using a Q-switched Nd:YAG laser equipped with a treatment beam diameter that was adjustable in 1 mm increments and a setting that would enable the maximally achievable diameter ("MAX-ON" setting) with any fluence. Tattoos were randomly bisected and treated on one side with the MAX-ON setting and on the contralateral side with a standard 4-mm-diameter spot ("MAX-OFF" setting). Photographs were taken 8 weeks following each treatment and each half-tattoo was evaluated for clearance on a 10-point scale by physicians blinded to the treatment conditions. Tattoo clearance was greater on the side treated with the MAX-ON setting in a statistically significant manner following the 1st through 4th treatments, with the MAX-OFF treatment site approaching the clearance of the MAX-ON treatment site after the 5th and 6th treatments. This high-energy, Q-switched Nd:YAG laser with a continuously variable spot-size safely and effectively removes tattoos, with greater removal when using a larger spot-size. © 2013 Wiley Periodicals, Inc.
Tarabout, Christophe; Roux, Stéphane; Gobeaux, Frédéric; Fay, Nicolas; Pouget, Emilie; Meriadec, Cristelle; Ligeti, Melinda; Thomas, Daniel; IJsselstijn, Maarten; Besselievre, François; Buisson, David-Alexandre; Verbavatz, Jean-Marc; Petitjean, Michel; Valéry, Céline; Perrin, Lionel; Rousseau, Bernard; Artzner, Franck; Paternostre, Maité; Cintrat, Jean-Christophe
2011-01-01
Supramolecular self-assembly is an attractive pathway for bottom-up synthesis of novel nanomaterials. In particular, this approach allows the spontaneous formation of structures of well-defined shapes and monodisperse characteristic sizes. Because nanotechnology mainly relies on size-dependent physical phenomena, the control of monodispersity is required, but the possibility of tuning the size is also essential. For self-assembling systems, shape, size, and monodispersity are mainly settled by the chemical structure of the building block. Attempts to change the size notably by chemical modification usually end up with the loss of self-assembly. Here, we generated a library of 17 peptides forming nanotubes of monodisperse diameter ranging from 10 to 36 nm. A structural model taking into account close contacts explains how a modification of a few Å of a single aromatic residue induces a fourfold increase in nanotube diameter. The application of such a strategy is demonstrated by the formation of silica nanotubes of various diameters. PMID:21518895
Miyawaki, Shinjiro; Tawhai, Merryn H.; Hoffman, Eric A.; Wenzel, Sally E.; Lin, Ching-Long
2016-01-01
We propose a method to construct three-dimensional airway geometric models based on airway skeletons, or centerlines (CLs). Given a CT-segmented airway skeleton and surface, the proposed CL-based method automatically constructs subject-specific models that contain anatomical information regarding branches, include bifurcations and trifurcations, and extend from the trachea to terminal bronchioles. The resulting model can be anatomically realistic with the assistance of an image-based surface; alternatively a model with an idealized skeleton and/or branch diameters is also possible. This method systematically identifies and classifies trifurcations to successfully construct the models, which also provides the number and type of trifurcations for the analysis of the airways from an anatomical point of view. We applied this method to 16 normal and 16 severe asthmatic subjects using their computed tomography images. The average distance between the surface of the model and the image-based surface was 11% of the average voxel size of the image. The four most frequent locations of trifurcations were the left upper division bronchus, left lower lobar bronchus, right upper lobar bronchus, and right intermediate bronchus. The proposed method automatically constructed accurate subject-specific three-dimensional airway geometric models that contain anatomical information regarding branches using airway skeleton, diameters, and image-based surface geometry. The proposed method can construct (i) geometry automatically for population-based studies, (ii) trifurcations to retain the original airway topology, (iii) geometry that can be used for automatic generation of computational fluid dynamics meshes, and (iv) geometry based only on a skeleton and diameters for idealized branches. PMID:27704229
7 CFR 51.2952 - Size specifications.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 12 percent, by count, pass through a round opening 96/64 inches in diameter; (b) Jumbo size. Jumbo size means walnuts of which not over 12 percent, by count, pass through a round opening 80/64 inches in... round opening 77/64 inches in diameter; except that for walnuts of the Eureka variety and type, such...
7 CFR 51.2952 - Size specifications.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 12 percent, by count, pass through a round opening 96/64 inches in diameter; (b) Jumbo size. Jumbo size means walnuts of which not over 12 percent, by count, pass through a round opening 80/64 inches in... round opening 77/64 inches in diameter; except that for walnuts of the Eureka variety and type, such...
NASA Astrophysics Data System (ADS)
Matthews, John A.; Owen, Geraint; McEwen, Lindsey J.; Shakesby, Richard A.; Hill, Jennifer L.; Vater, Amber E.; Ratcliffe, Anna C.
2017-11-01
This regional inventory and study of a globally uncommon landform type reveals similarities in form and process between craters produced by snow-avalanche and meteorite impacts. Fifty-two snow-avalanche impact craters (mean diameter 85 m, range 10-185 m) were investigated through field research, aerial photographic interpretation and analysis of topographic maps. The craters are sited on valley bottoms or lake margins at the foot of steep avalanche paths (α = 28-59°), generally with an easterly aspect, where the slope of the final 200 m of the avalanche path (β) typically exceeds 15°. Crater diameter correlates with the area of the avalanche start zone, which points to snow-avalanche volume as the main control on crater size. Proximal erosional scars ('blast zones') up to 40 m high indicate up-range ejection of material from the crater, assisted by air-launch of the avalanches and impulse waves generated by their impact into water-filled craters. Formation of distal mounds up to 12 m high of variable shape is favoured by more dispersed down-range deposition of ejecta. Key to the development of snow-avalanche impact craters is the repeated occurrence of topographically-focused snow avalanches that impact with a steep angle on unconsolidated sediment. Secondary craters or pits, a few metres in diameter, are attributed to the impact of individual boulders or smaller bodies of snow ejected from the main avalanche. The process of crater formation by low-density, low-velocity, large-volume snow flows occurring as multiple events is broadly comparable with cratering by single-event, high-density, high-velocity, small-volume projectiles such as small meteorites. Simple comparative modelling of snow-avalanche events associated with a crater of average size (diameter 85 m) indicates that the kinetic energy of a single snow-avalanche impact event is two orders of magnitude less than that of a single meteorite-impact event capable of producing a crater of similar size, which is consistent with the incremental development of snow-avalanche impact craters through the Holocene.
Minimization of skin incisions at stripping by Mayo of large-diameter veins.
Tsukanov, Yu
2018-03-15
To study the possibility of minimization of the skin incisions up to a puncture size at stripping by Mayo with the use of the stripper with an oval-ring head for large-diameter veins. The problem is solved due to the geometrical changing of the stripper head from a round to an oval one. The laboratory experiment showed that with a vein diameter of 10-20 mm the total cross-sectional area of its walls constituted 13.61 mm2, with a diameter of more than 20 mm it was 19.98 mm2. There were designed three types of the external dimensions for the stripper: 3.0 х 6.0 mm; 3,5 х 7.0 mm and 4.0 х 8.0 mm. From 1997 to 2017 the stripper with an oval-ring head was used in 1274 patients (male, n=421; female, n=853) for treating 1832 lower limbs. Average age was 46.4±12.3 years (range, 29 to 73). GSV and SSV stripping was performed in 1165 and 137 cases respectively in patients with the trunk diameter of more than 10 mm, severe vein tortuosity, for a vein located immediately under the skin, as well as for patients with the history of thrombophlebitis. The pain level in the 1st evening after the operation was 1.59, on the 7th day it decreased to 0.12 according to VAS-10. The motion activity level in the 1st evening after the operation was 7.24, on the 7th day it decreased to 9.96 according to VAS-10. All patients had primary wound healing. Hematomas along the location of the eliminated veins were of a moderate nature and resolved, on average, within 17 days. With the GSV diameter of 10-20 mm the skin scars were of 2.93 mm (95% CI: 3.09 mm - 4.47 mm), with the GSV diameter of more than 20 mm the skin scars were of 4.10 mm (95% CI: 4.01 mm - 5.07 mm). After 3 months 1102 patients (86,5%) were very satisfied and 172 (13,5%) were just satisfied with the performed operation. The use of the proposed stripper with an oval-ring head in patients with large-diameter subcutaneous trunks leads to the minimization of the skin incisions up to the punctures and, in general, makes the surgery significantly less traumatic, providing a quick recovery and minimization of the skin scars.
[Distribution of atmospheric ultrafine particles during haze weather in Hangzhou].
Chen, Qiu-Fang; Sun, Zai; Xie, Xiao-Fang
2014-08-01
Atmospheric ultrafine particles (UFPs) were monitored with fast mobility particle sizer (FMPS) in continuous haze weather and the haze fading process during December 6 to 11, 2013 in Hangzhou. Particle concentration and size distribution were studied associated with meteorological factors. The results showed that number concentrations were the highest at night and began to reduce in the morning. There was a small peak at 8 o'clock in the morning and 18 o'clock in the afternoon. It showed an obvious peak traffic source, which indicated that traffic emissions played a great role in the atmospheric pollution. During haze weather, the highest number concentration of UFPs reached 8 x 10(4) cm(-3). Particle size spectrum distribution was bimodal, the peak particle sizes were 15 nm and 100 nm respectively. Majority of UFPs were Aitken mode and Accumulation mode and the size of most particles concentrated near 100 nm. Average CMD(count medium diameter) was 85.89 nm. During haze fading process, number concentration and particles with size around 100 nm began to reduce and peak size shifted to small size. Nuclear modal particles increased and were more than accumulation mode. Average CMD was 58.64 nm. Meteorological factors such as the visibility and wind were negatively correlated with the particle number concentration. Correlation coefficient R were -0.225 and - 0.229. The humidity was correlated with number concentration. Correlation coefficient R was 0.271. The atmosphere was stable in winter and the level temperature had small correlation with number concentration. Therefore, study on distribution of atmospheric ultrafine particles during haze weather had the significance on the formation mechanism and control of haze weather.
Wang, Liang; Yuan, Jin; Jiang, Hong; Yan, Wentao; Cintrón-Colón, Hector R; Perez, Victor L; DeBuc, Delia C; Feuer, William J; Wang, Jianhua
2016-03-01
This study determined (1) how many vessels (i.e., the vessel sampling) are needed to reliably characterize the bulbar conjunctival microvasculature and (2) if characteristic information can be obtained from the distribution histogram of the blood flow velocity and vessel diameter. Functional slitlamp biomicroscope was used to image hundreds of venules per subject. The bulbar conjunctiva in five healthy human subjects was imaged on six different locations in the temporal bulbar conjunctiva. The histograms of the diameter and velocity were plotted to examine whether the distribution was normal. Standard errors were calculated from the standard deviation and vessel sample size. The ratio of the standard error of the mean over the population mean was used to determine the sample size cutoff. The velocity was plotted as a function of the vessel diameter to display the distribution of the diameter and velocity. The results showed that the sampling size was approximately 15 vessels, which generated a standard error equivalent to 15% of the population mean from the total vessel population. The distributions of the diameter and velocity were not only unimodal, but also somewhat positively skewed and not normal. The blood flow velocity was related to the vessel diameter (r=0.23, P<0.05). This was the first study to determine the sampling size of the vessels and the distribution histogram of the blood flow velocity and vessel diameter, which may lead to a better understanding of the human microvascular system of the bulbar conjunctiva.
NASA Astrophysics Data System (ADS)
Alajmi, Mohamed F.; Ahmed, Jahangeer; Hussain, Afzal; Ahamad, Tansir; Alhokbany, Norah; Amir, Samira; Ahmad, Tokeer; Alshehri, Saad M.
2018-04-01
Iron oxide (Fe3O4) nanoparticles (NPs) were prepared at room temperature by one-step synthesis via green chemistry using aqueous extracts of Pandanus odoratissimus leaves. Fe3O4 NPs show uniform particle size distribution with an average diameter of 5.0 nm. BET surface area and average pore diameter of the nanoparticles were found to be 150 m2/g and 3.0 nm, respectively. FTIR, Raman, EDAX and XPS studies were also carried out to confirm the phase purity of the prepared materials. Electrochemical water splitting reactions have been carried out using Fe3O4 NPs as electrocatalysts in 0.1 M KOH electrolyte solution. Polarization studies confirm dual nature of Fe3O4 electro-catalysts in water electrolysis for oxygen reduction reaction (ORR) and oxygen evolution reaction (OER). Potentiodynamic polarization curves reveal low Tafel values of 295 and 126 mV/dec (± 2) for OER and ORR, respectively. The overpotential for water oxidation reaction was found to be 390 mV (± 5) at the current density of 1 mA/cm2 in 0.1 M KOH. Chronoamperometry and chronopotentiometry experiments were conducted for stability tests of the electrodes.
Preparation and Characterization of Gelatin Nanofibers Containing Silver Nanoparticles
Jeong, Lim; Park, Won Ho
2014-01-01
Ag nanoparticles (NPs) were synthesized in formic acid aqueous solutions through chemical reduction. Formic acid was used for a reducing agent of Ag precursor and solvent of gelatin. Silver acetate, silver tetrafluoroborate, silver nitrate, and silver phosphate were used as Ag precursors. Ag+ ions were reduced into Ag NPs by formic acid. The formation of Ag NPs was characterized by a UV-Vis spectrophotometer. Ag NPs were quickly generated within a few minutes in silver nitrate (AgNO3)/formic acid solution. As the water content of formic acid aqueous solution increased, more Ag NPs were generated, at a higher rate and with greater size. When gelatin was added to the AgNO3/formic acid solution, the Ag NPs were stabilized, resulting in smaller particles. Moreover, gelatin limits further aggregation of Ag NPs, which were effectively dispersed in solution. The amount of Ag NPs formed increased with increasing concentration of AgNO3 and aging time. Gelatin nanofibers containing Ag NPs were fabricated by electrospinning. The average diameters of gelatin nanofibers were 166.52 ± 32.72 nm, but these decreased with the addition of AgNO3. The average diameters of the Ag NPs in gelatin nanofibers ranged between 13 and 25 nm, which was confirmed by transmission electron microscopy (TEM). PMID:24758929
Cevasco, Marisa; Mick, Stephanie L; Kwon, Michael; Lee, Lawrence S; Chen, Edward P; Chen, Frederick Y
2013-05-01
Currently, there is no universal standard for sizing bioprosthetic aortic valves. Hence, a standardized comparison was performed to clarify this issue. Every size of four commercially available bioprosthetic aortic valves marketed in the United States (Biocor Supra; Mosaic Ultra; Magna Ease; Mitroflow) was obtained. Subsequently, custom sizers were created that were accurate to 0.0025 mm to represent aortic roots 18 mm through 32 mm, and these were used to measure the external diameter of each valve. Using the effective orifice area (EOA) and transvalvular pressure gradient (TPG) data submitted to the FDA, a comparison was made between the hemodynamic properties of valves with equivalent manufacturer stated sizes and valves with equivalent measured external diameters. Based on manufacturer size alone, the valves at first seemed to be hemodynamically different from each other, with Mitroflow valves appearing to be hemodynamically superior, having a large EOA and equivalent or superior TPG (p < 0.05). However, Mitroflow valves had a larger measured external diameter than the other valves of a given numerical manufacturer size. Valves with equivalent external diameters were then compared, regardless of the stated manufacturer sizes. For truly equivalently sized valves (i.e., by measured external diameter) there was no clear hemodynamic difference. There was no statistical difference in the EOAs between the Biocor Supra, Mosaic Ultra, and Mitroflow valves, and the Magna Ease valve had a statistically smaller EOA (p < 0.05). On comparing the mean TPG, the Biocor Supra and Mitroflow valves had statistically equivalent gradients to each other, as did the Mosaic Ultra and Magna Ease valves. When comparing valves of the same numerical manufacturer size, there appears to be a difference in hemodynamic performance across different manufacturers' valves according to FDA data. However, comparing equivalently measured valves eliminates the differences between valves produced by different manufacturers.
Vo, Minh D; Papavassiliou, Dimitrios V
2016-04-15
Dissipative particle dynamics (DPD) simulations were utilized to investigate the ability of sodium dodecyl sulfate (SDS) to adsorb inside a single-walled, arm-chair carbon nanotube (SWCNT), as well as the effect of surfactant on the properties of water inside the SWCNT. The diameter of the SWCNT varied from 1 to 5 nm. The radial and axial density profiles of water inside the SWCNTs were computed and compared with published molecular dynamics results. The average residence time and diffusivity were also calculated to show the size effect on mobility of water inside the SWCNT. It was found that nanotubes with diameter smaller than 3 nm do not allow SDS molecules to enter the SWCNT space. For larger SWCNT diameter, SDS adsorbed inside and outside the nanotube. When SDS was adsorbed in the hollow part of the SWCNT, the behavior of water inside the nanotube was found to be significantly changed. Both radial and axial density profiles of water inside the SWCNT fluctuated strongly and were different from those in bulk phase. In addition, SDS molecules increased the retention of water beads inside SWCNT (d ≥ 3nm) while water diffusivity was decreased.
Oxygenation of the Intraportally Transplanted Pancreatic Islet
2016-01-01
Intraportal islet transplantation (IT) is not widely utilized as a treatment for type 1 diabetes. Oxygenation of the intraportally transplanted islet has not been studied extensively. We present a diffusion-reaction model that predicts the presence of an anoxic core and a larger partly functional core within intraportally transplanted islets. Four variables were studied: islet diameter, islet fractional viability, external oxygen partial pressure (P) (in surrounding portal blood), and presence or absence of a thrombus on the islet surface. Results indicate that an islet with average size and fractional viability exhibits an anoxic volume fraction (AVF) of 14% and a function loss of 72% at a low external P. Thrombus formation increased AVF to 30% and function loss to 92%, suggesting that the effect of thrombosis may be substantial. External P and islet diameter accounted for the greatest overall impact on AVF and loss of function. At our institutions, large human alloislets (>200 μm diameter) account for ~20% of total islet number but ~70% of total islet volume; since most of the total transplanted islet volume is accounted for by large islets, most of the intraportal islet cells are likely to be anoxic and not fully functional. PMID:27872862
Oxygenation of the Intraportally Transplanted Pancreatic Islet.
Suszynski, Thomas M; Avgoustiniatos, Efstathios S; Papas, Klearchos K
2016-01-01
Intraportal islet transplantation (IT) is not widely utilized as a treatment for type 1 diabetes. Oxygenation of the intraportally transplanted islet has not been studied extensively. We present a diffusion-reaction model that predicts the presence of an anoxic core and a larger partly functional core within intraportally transplanted islets. Four variables were studied: islet diameter, islet fractional viability, external oxygen partial pressure ( P ) (in surrounding portal blood), and presence or absence of a thrombus on the islet surface. Results indicate that an islet with average size and fractional viability exhibits an anoxic volume fraction (AVF) of 14% and a function loss of 72% at a low external P . Thrombus formation increased AVF to 30% and function loss to 92%, suggesting that the effect of thrombosis may be substantial. External P and islet diameter accounted for the greatest overall impact on AVF and loss of function. At our institutions, large human alloislets (>200 μ m diameter) account for ~20% of total islet number but ~70% of total islet volume; since most of the total transplanted islet volume is accounted for by large islets, most of the intraportal islet cells are likely to be anoxic and not fully functional.
Distribution of diameters for Erdős-Rényi random graphs.
Hartmann, A K; Mézard, M
2018-03-01
We study the distribution of diameters d of Erdős-Rényi random graphs with average connectivity c. The diameter d is the maximum among all the shortest distances between pairs of nodes in a graph and an important quantity for all dynamic processes taking place on graphs. Here we study the distribution P(d) numerically for various values of c, in the nonpercolating and percolating regimes. Using large-deviation techniques, we are able to reach small probabilities like 10^{-100} which allow us to obtain the distribution over basically the full range of the support, for graphs up to N=1000 nodes. For values c<1, our results are in good agreement with analytical results, proving the reliability of our numerical approach. For c>1 the distribution is more complex and no complete analytical results are available. For this parameter range, P(d) exhibits an inflection point, which we found to be related to a structural change of the graphs. For all values of c, we determined the finite-size rate function Φ(d/N) and were able to extrapolate numerically to N→∞, indicating that the large-deviation principle holds.
Distribution of diameters for Erdős-Rényi random graphs
NASA Astrophysics Data System (ADS)
Hartmann, A. K.; Mézard, M.
2018-03-01
We study the distribution of diameters d of Erdős-Rényi random graphs with average connectivity c . The diameter d is the maximum among all the shortest distances between pairs of nodes in a graph and an important quantity for all dynamic processes taking place on graphs. Here we study the distribution P (d ) numerically for various values of c , in the nonpercolating and percolating regimes. Using large-deviation techniques, we are able to reach small probabilities like 10-100 which allow us to obtain the distribution over basically the full range of the support, for graphs up to N =1000 nodes. For values c <1 , our results are in good agreement with analytical results, proving the reliability of our numerical approach. For c >1 the distribution is more complex and no complete analytical results are available. For this parameter range, P (d ) exhibits an inflection point, which we found to be related to a structural change of the graphs. For all values of c , we determined the finite-size rate function Φ (d /N ) and were able to extrapolate numerically to N →∞ , indicating that the large-deviation principle holds.
Efficient drug delivery using SiO2-layered double hydroxide nanocomposites.
Li, Li; Gu, Zi; Gu, Wenyi; Liu, Jian; Xu, Zhi Ping
2016-05-15
MgAl-layered double hydroxide (MgAl-LDH) nanoparticles have great potentials in drug and siRNA delivery. In this work, we used a nanodot-coating strategy to prepare SiO2 dot-coated layered double hydroxide (SiO2@MgAl-LDH) nanocomposites with good dispersibility and controllable size for drug delivery. The optimal SiO2@MgAl-LDH nanocomposite was obtained by adjusting synthetic parameters including the mass ratio of MgAl-LDH to SiO2, the mixing temperature and time. The optimal SiO2@MgAl-LDH nanocomposite was shown to have SiO2 nanodots (10-15nm in diameter) evenly deposited on the surface of MgAl-LDHs (110nm in diameter) with the plate-like morphology and the average hydrodynamic diameter of 170nm. We further employed SiO2@MgAl-LDH nanocomposite as a nanocarrier to deliver methotrexate (MTX), a chemotherapy drug, to the human osteosarcoma cell (U2OS) and found that MTX delivered by SiO2@MgAl-LDH nanocomposite apparently inhibited the U2OS cell growth. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Yuan, Haojie; Zhang, Shouchun; Lu, Chunxiang
2014-10-01
Interests on carbon fiber-reinforced thermoplastic composites are growing rapidly, but the challenges with poor interfacial adhesion have slowed their adoption. In this work, a polyether sulfone (PES) emulsion sizing was prepared successfully for increased interfacial adhesion of carbon fiber/PES composites. To obtain a high-quality PES emulsion sizing, the key factor, emulsifier concentration, was studied by dynamic light scattering technique. The results demonstrated that the suitable weight ratio of PES to emulsifier was 8:3, and the resulting PES emulsion sizing had an average particle diameter of 117 nm and Zeta potential of -52.6 mV. After sizing, the surface oxygen-containing functional groups, free energy and wettability of carbon fibers increased significantly, which were advantageous to promote molecular-level contact between carbon fiber and PES. Finally, short beam shear tests were performed to evaluate the interfacial adhesion of carbon fiber/PES composites. The results indicated that PES emulsion sizing played a critical role for the enhanced interfacial adhesion in carbon fiber/PES composites, and a 26% increase of interlaminar shear strength was achieved, because of the improved fiber surface wettability and interfacial compatibility between carbon fiber and PES.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robertson, Andrew K. H.; Basran, Parminder S.; Thomas, Steven D.
Purpose: To investigate the effects of brachytherapy seed size on the quality of x-ray computed tomography (CT), ultrasound (US), and magnetic resonance (MR) images and seed localization through comparison of the 6711 and 9011 {sup 125}I sources. Methods: For CT images, an acrylic phantom mimicking a clinical implantation plan and embedded with low contrast regions of interest (ROIs) was designed for both the 0.774 mm diameter 6711 (standard) and the 0.508 mm diameter 9011 (thin) seed models (Oncura, Inc., and GE Healthcare, Arlington Heights, IL). Image quality metrics were assessed using the standard deviation of ROIs between the seeds andmore » the contrast to noise ratio (CNR) within the low contrast ROIs. For US images, water phantoms with both single and multiseed arrangements were constructed for both seed sizes. For MR images, both seeds were implanted into a porcine gel and imaged with pelvic imaging protocols. The standard deviation of ROIs and CNR values were used as metrics of artifact quantification. Seed localization within the CT images was assessed using the automated seed finder in a commercial brachytherapy treatment planning system. The number of erroneous seed placements and the average and maximum error in seed placements were recorded as metrics of the localization accuracy. Results: With the thin seeds, CT image noise was reduced from 48.5 {+-} 0.2 to 32.0 {+-} 0.2 HU and CNR improved by a median value of 74% when compared with the standard seeds. Ultrasound image noise was measured at 50.3 {+-} 17.1 dB for the thin seed images and 50.0 {+-} 19.8 dB for the standard seed images, and artifacts directly behind the seeds were smaller and less prominent with the thin seed model. For MR images, CNR of the standard seeds reduced on average 17% when using the thin seeds for all different imaging sequences and seed orientations, but these differences are not appreciable. Automated seed localization required an average ({+-}SD) of 7.0 {+-} 3.5 manual corrections in seed positions for the thin seed scans and 3.0 {+-} 1.2 manual corrections in seed positions for the standard seed scans. The average error in seed placement was 1.2 mm for both seed types and the maximum error in seed placement was 2.1 mm for the thin seed scans and 1.8 mm for the standard seed scans. Conclusions: The 9011 thin seeds yielded significantly improved image quality for CT and US images but no significant differences in MR image quality.« less
Shiitake mushroom production on small diameter oak logs in Ohio
S.M. Bratkovich
1991-01-01
Yields of different strains of shiitake mushrooms (Lentinus edodes) were evaluated when produced on small diameter oak logs in Ohio. Logs averaging between 3-4 inches in diameter were inoculated with four spawn strains in 1985.
Modeling of Fibrin Gels Based on Confocal Microscopy and Light-Scattering Data
Magatti, Davide; Molteni, Matteo; Cardinali, Barbara; Rocco, Mattia; Ferri, Fabio
2013-01-01
Fibrin gels are biological networks that play a fundamental role in blood coagulation and other patho/physiological processes, such as thrombosis and cancer. Electron and confocal microscopies show a collection of fibers that are relatively monodisperse in diameter, not uniformly distributed, and connected at nodal points with a branching order of ∼3–4. Although in the confocal images the hydrated fibers appear to be quite straight (mass fractal dimension Dm = 1), for the overall system 1
Two independent measurements of Debye lengths in doped nonpolar liquids.
Prieve, D C; Hoggard, J D; Fu, R; Sides, P J; Bethea, R
2008-02-19
Electric current measurements were performed between 2.5 cm x 7.5 cm parallel-plate electrodes separated by 1.2 mm of heptane doped with 0-15% w/w poly(isobutylene succinimide) (PIBS) having a molecular weight of about 1700. The rapid (microsecond) initial charging of the capacitor can be used to infer the dielectric constant of the solution. The much slower decay of current arising from the polarization of electrodes depends on the differential capacitance of the diffuse clouds of charge carriers accumulating next to each electrode and on the ohmic resistance of the fluid. Using the Gouy-Chapman model for the differential capacitance, Debye lengths of 80-600 nm were deduced that decrease with increasing concentration of PIBS. Values of the Debye lengths were confirmed by performing independent measurements of double-layer repulsion between a 6 microm polystyrene (PS) latex sphere and a PS-coated glass plate using total internal reflection microscopy in the same solutions. The charge carriers appear to be inverted PIBS micelles having apparent Stokes diameters of 20-40 nm. Dynamic light scattering reveals a broad distribution of sizes having an intensity-averaged diameter of 15 nm. This smaller size might arise (1) from overestimating the electrophoretic mobility of micelles by treating them as point charges or (2) because charged micelles are larger on average than uncharged micelles. When Faradaic reactions and zeta potentials on the electrodes can be neglected, such current versus time experiments yield values for the Debye length and ionic strength with less effort than force measurements. To obtain the concentration of charge carriers from measurements of conductivity, the mobility of the charge carriers must be known.
Abdelsayed, Victor; El-Shall, M Samy
2014-08-07
This work reports the direct observation and separation of size-selected aluminum nanoparticles acting as heterogeneous nuclei for the condensation of supersaturated vapors of both polar and nonpolar molecules. In the experiment, we study the condensation of supersaturated acetonitrile and n-hexane vapors on charged and neutral Al nanoparticles by activation of the metal nanoparticles to act as heterogeneous nuclei for the condensation of the organic vapor. Aluminum seed nanoparticles with diameters of 1 and 2 nm are capable of acting as heterogeneous nuclei for the condensation of supersaturated acetonitrile and hexane vapors. The comparison between the Kelvin and Fletcher diameters indicates that for the heterogeneous nucleation of both acetonitrile and hexane vapors, particles are activated at significantly smaller sizes than predicted by the Kelvin equation. The activation of the Al nanoparticles occurs at nearly 40% and 65% of the onset of homogeneous nucleation of acetonitrile and hexane supersaturated vapors, respectively. The lower activation of the charged Al nanoparticles in acetonitrile vapor is due to the charge-dipole interaction which results in rapid condensation of the highly polar acetonitrile molecules on the charged Al nanoparticles. The charge-dipole interaction decreases with increasing the size of the Al nanoparticles and therefore at low supersaturations, most of the heterogeneous nucleation events are occurring on neutral nanoparticles. No sign effect has been observed for the condensation of the organic vapors on the positively and negatively charged Al nanoparticles. The present approach of generating metal nanoparticles by pulsed laser vaporization within a supersaturated organic vapor allows for efficient separation between nucleation and growth of the metal nanoparticles and, consequently controls the average particle size, particle density, and particle size distribution within the liquid droplets of the condensing vapor. Strong correlation is found between the seed nanoparticle's size and the degree of the supersaturation of the condensing vapor. This result and the agreement among the calculated Kelvin diameters and the size of the nucleating Al nanoparticles determined by transmission electron microscopy provide strong proof for the development of a new approach for the separation and characterization of heterogeneous nuclei formed in organic vapors. These processes can take place in the atmosphere by a combination of several organic species including polar compounds which could be very efficient in activating charged nanoparticles and cluster ions of atmospheric relevance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdelsayed, Victor; Samy El-Shall, M., E-mail: mselshal@vcu.edu
This work reports the direct observation and separation of size-selected aluminum nanoparticles acting as heterogeneous nuclei for the condensation of supersaturated vapors of both polar and nonpolar molecules. In the experiment, we study the condensation of supersaturated acetonitrile and n-hexane vapors on charged and neutral Al nanoparticles by activation of the metal nanoparticles to act as heterogeneous nuclei for the condensation of the organic vapor. Aluminum seed nanoparticles with diameters of 1 and 2 nm are capable of acting as heterogeneous nuclei for the condensation of supersaturated acetonitrile and hexane vapors. The comparison between the Kelvin and Fletcher diameters indicatesmore » that for the heterogeneous nucleation of both acetonitrile and hexane vapors, particles are activated at significantly smaller sizes than predicted by the Kelvin equation. The activation of the Al nanoparticles occurs at nearly 40% and 65% of the onset of homogeneous nucleation of acetonitrile and hexane supersaturated vapors, respectively. The lower activation of the charged Al nanoparticles in acetonitrile vapor is due to the charge-dipole interaction which results in rapid condensation of the highly polar acetonitrile molecules on the charged Al nanoparticles. The charge-dipole interaction decreases with increasing the size of the Al nanoparticles and therefore at low supersaturations, most of the heterogeneous nucleation events are occurring on neutral nanoparticles. No sign effect has been observed for the condensation of the organic vapors on the positively and negatively charged Al nanoparticles. The present approach of generating metal nanoparticles by pulsed laser vaporization within a supersaturated organic vapor allows for efficient separation between nucleation and growth of the metal nanoparticles and, consequently controls the average particle size, particle density, and particle size distribution within the liquid droplets of the condensing vapor. Strong correlation is found between the seed nanoparticle's size and the degree of the supersaturation of the condensing vapor. This result and the agreement among the calculated Kelvin diameters and the size of the nucleating Al nanoparticles determined by transmission electron microscopy provide strong proof for the development of a new approach for the separation and characterization of heterogeneous nuclei formed in organic vapors. These processes can take place in the atmosphere by a combination of several organic species including polar compounds which could be very efficient in activating charged nanoparticles and cluster ions of atmospheric relevance.« less
Encapsulation of nanoclusters in dried gel materials via an inverse micelle/sol gel synthesis
Martino, A.; Yamanaka, S.A.; Kawola, J.S.; Showalter, S.K.; Loy, D.A.
1998-09-29
A dried gel material sterically entrapping nanoclusters of a catalytically active material and a process to make the material via an inverse micelle/sol-gel synthesis are disclosed. A surfactant is mixed with an apolar solvent to form an inverse micelle solution. A salt of a catalytically active material, such as gold chloride, is added along with a silica gel precursor to the solution to form a mixture. To the mixture are then added a reducing agent for the purpose of reducing the gold in the gold chloride to atomic gold to form the nanoclusters and a condensing agent to form the gel which sterically entraps the nanoclusters. The nanoclusters are normally in the average size range of from 5--10 nm in diameter with a monodisperse size distribution. 1 fig.
NASA Technical Reports Server (NTRS)
Saha, H.
1981-01-01
The test data and an analysis of the heat transfer characteristics of a solar thermal energy storage bed utilizing water filled cans and standard bricks as energy storage medium are presented. This experimental investigation was initiated to find a usable heat intensive solar thermal storage device other than rock storage and water tank. Four different sizes of soup cans were stacked in a chamber in three different arrangements-vertical, horizontal, and random. Air is used as transfer medium for charging and discharge modes at three different mass flow rates and inlet air temperature respectively. These results are analyzed and compared, which show that a vertical stacking and medium size cans with Length/Diameter (L/D) ratio close to one have better average characteristics of heat transfer and pressure drop.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Yakun; Li, Xiang; Segars, W. Paul
2014-02-15
Purpose: Given the radiation concerns inherent to the x-ray modalities, accurately estimating the radiation doses that patients receive during different imaging modalities is crucial. This study estimated organ doses, effective doses, and risk indices for the three clinical chest x-ray imaging techniques (chest radiography, tomosynthesis, and CT) using 59 anatomically variable voxelized phantoms and Monte Carlo simulation methods. Methods: A total of 59 computational anthropomorphic male and female extended cardiac-torso (XCAT) adult phantoms were used in this study. Organ doses and effective doses were estimated for a clinical radiography system with the capability of conducting chest radiography and tomosynthesis (Definiummore » 8000, VolumeRAD, GE Healthcare) and a clinical CT system (LightSpeed VCT, GE Healthcare). A Monte Carlo dose simulation program (PENELOPE, version 2006, Universitat de Barcelona, Spain) was used to mimic these two clinical systems. The Duke University (Durham, NC) technique charts were used to determine the clinical techniques for the radiographic modalities. An exponential relationship between CTDI{sub vol} and patient diameter was used to determine the absolute dose values for CT. The simulations of the two clinical systems compute organ and tissue doses, which were then used to calculate effective dose and risk index. The calculation of the two dose metrics used the tissue weighting factors from ICRP Publication 103 and BEIR VII report. Results: The average effective dose of the chest posteroanterior examination was found to be 0.04 mSv, which was 1.3% that of the chest CT examination. The average effective dose of the chest tomosynthesis examination was found to be about ten times that of the chest posteroanterior examination and about 12% that of the chest CT examination. With increasing patient average chest diameter, both the effective dose and risk index for CT increased considerably in an exponential fashion, while these two dose metrics only increased slightly for radiographic modalities and for chest tomosynthesis. Effective and organ doses normalized to mAs all illustrated an exponential decrease with increasing patient size. As a surface organ, breast doses had less correlation with body size than that of lungs or liver. Conclusions: Patient body size has a much greater impact on radiation dose of chest CT examinations than chest radiography and tomosynthesis. The size of a patient should be considered when choosing the best thoracic imaging modality.« less
History of water-column anoxia in the Black Sea indicated by pyrite framboid size distributions
Wilkin, R.T.; Arthur, M.A.; Dean, W.E.
1997-01-01
A detailed study of size distributions of framboidal pyrite in Holocene Black Sea sediments establishes the timing of a change from deposition under an oxic water column to deposition under an anoxic and sulfidic water column. In the most recent carbonate-rich sediments (Unit I) and in the organic carbon-rich sapropel (Unit II), framboid size distributions are remarkably uniform (mean diameter= 5 ??m); over 95% of the framboids in Unit I and Unit II are < 7 ??m in diameter. These properties of framboidal pyrite are consistent with framboid nucleation and growth within an anoxic and sulfidic water column, followed by transport to the sediment-water interface, cessation of pyrite growth due to the exhaustion of reactive iron, and subsequent burial. In contrast, the organic carbon-poor sediments of lacustrine Unit III contain pyrite framboids that are generally much larger in size (mean diameter = 10 ??m). In Unit III, over 95% of the framboids are < 25 ??m in diameter, 40% of framboids are between 7 ??m and 25 ??m, and framboids up to 50 ??m in diameter are present. This distribution of sizes suggests framboid nucleation and growth within anoxic sediment porewaters. These new data on size distributions of framboidal pyrite confirm that the development of water-column anoxia in the Black Sea coincided with the initiation of deposition of laminated Unit II sapropels.
Growth control of carbon nanotubes using by anodic aluminum oxide nano templates.
Park, Yong Seob; Choi, Won Seek; Yi, Junsin; Lee, Jaehyeong
2014-05-01
Anodic Aluminum Oxide (AAO) template prepared in acid electrolyte possess regular and highly anisotropic porous structure with pore diameter range from five to several hundred nanometers, and with a density of pores ranging from 10(9) to 10(11) cm(-2). AAO can be used as microfilters and templates for the growth of CNTs and metal or semiconductor nanowires. Varying anodizing conditions such as temperature, electrolyte, applied voltage, anodizing and widening time, one can control the diameter, the length, and the density of pores. In this work, we deposited Al thin film by radio frequency magnetron sputtering method to fabricate AAO nano template and synthesized multi-well carbon nanotubes on a glass substrate by microwave plasma-enhanced chemical vapor deposition (MPECVD). AAO nano-porous templates with various pore sizes and depths were introduced to control the dimension and density of CNT arrays. The AAO nano template was synthesize on glass by two-step anodization technique. The average diameter and interpore distance of AAO nano template are about 65 nm and 82 nm. The pore density and AAO nano template thickness are about 2.1 x 10(10) pores/cm2 and 1 microm, respectively. Aligned CNTs on the AAO nano template were synthesized by MPECVD at 650 degrees C with the Ni catalyst layer. The length and diameter of CNTs were grown 2 microm and 50 nm, respectively.
NASA Technical Reports Server (NTRS)
Foughner, J. T., Jr.; Alexander, W. C.
1974-01-01
Transonic wind-tunnel studies were conducted with modified cross, hemisflo, and disk-gap-band parachute models in the wake of a cone-cylinder shape forebody. The basic cross design was modified with the addition of a circumferential constraining band at the lower edge of the canopy panels. The tests covered a Mach number range of 0.3 to 1.2 and a dynamic pressure range from 479 Newtons per square meter to 5746 Newtons per square meter. The parachute models were flexible textile-type structures and were tethered to a rigid forebody with a single flexible riser. Different size models of the modified cross and disk-gap-band canopies were tested to evaluate scale effects. Model reference diameters were 0.30, 0.61, and 1.07 meters (1.0, 2.0, and 3.5 ft) for the modified cross; and nominal diameters of 0.25 and 0.52 meter (0.83 and 1.7 ft) for the disk-gap-band; and 0.55 meter (1.8 ft) for the hemisflo. Reefing information is presented for the 0.61-meter-diameter cross and the 0.52-meter-diameter disk-gap-band. Results are presented in the form of the variation of steady-state average drag coefficient with Mach number. General stability characteristics of each parachute are discussed. Included are comments on canopy coning, spinning, and fluttering motions.
Microscopic Structure of Metal Whiskers
NASA Astrophysics Data System (ADS)
Borra, Vamsi; Georgiev, Daniel G.; Karpov, V. G.; Shvydka, Diana
2018-05-01
We present TEM images of the interior of metal whiskers (MWs) grown on electroplated Sn films. Along with earlier published information, our observations focus on a number of questions, such as, why MWs' diameters are in the micron range (significantly exceeding the typical nanosizes of nuclei in solids), why the diameters remain practically unchanged in the course of MW growth, what the nature of MW diameter stochasticity is, and what the origin of the well-known striation structure of MW side surfaces is. In an attempt to address such questions, we perform an in-depth study of MW structure at the nanoscale by detaching a MW from its original film, reducing its size to a thin slice by cutting its sides by a focused ion beam, and performing TEM on that structure. Also, we examine the root of the MW and Cu-Sn interface for the intermetallic compounds. Our TEM observations reveal a rich nontrivial morphology suggesting that MWs may consist of many side-by-side grown filaments. This structure appears to extend to the outside whisker surface and be the reason for the striation. In addition, we put forward a theory where nucleation of multiple thin metal needles results in micron-scale and larger MW diameters. This theory is developed in the average field approximation similar to the roughening transitions of metal surfaces. The theory also predicts MW nucleation barriers and other observed features.
Dai, Zhendong; Gorb, Stanislav N; Schwarz, Uli
2002-08-01
This paper studies slide-resisting forces generated by claws in the free-walking beetle Pachnoda marginata (Coleoptera, Scarabaeoidea) with emphasis on the relationship between the dimension of the claw tip and the substrate texture. To evaluate the force range by which the claw can interact with a substrate, forces generated by the freely moving legs were measured using a load cell force transducer. To obtain information about material properties of the claw, its mechanical strength was tested in a fracture experiment, and the internal structure of the fractured claw material was studied by scanning electron microscopy. The bending stress of the claw was evaluated as 143.4-684.2 MPa, depending on the cross-section model selected. Data from these different approaches led us to propose a model explaining the saturation of friction force with increased texture roughness. The forces are determined by the relative size of the surface roughness R(a) (or an average particle diameter) and the diameter of the claw tip. When surface roughness is much bigger than the claw tip diameter, the beetle can grasp surface irregularities and generate a high degree of attachment due to mechanical interlocking with substrate texture. When R(a) is lower than or comparable to the claw tip diameter, the frictional properties of the contact between claw and substrate particles play a key role in the generation of the friction force.
Measurement and properties of the dose-area product ratio in external small-beam radiotherapy.
Niemelä, Jarkko; Partanen, Mari; Ojala, Jarkko; Sipilä, Petri; Björkqvist, Mikko; Kapanen, Mika; Keyriläinen, Jani
2017-06-21
In small-beam radiation therapy (RT) the measurement of the beam quality parameter, i.e. the tissue-phantom ratio or TPR 20,10 , using a conventional point detector is a challenge. To obtain reliable results, one has to consider potential sources of error, including volume averaging and adjustment of the point detector into the narrow beam. To overcome these challenges, a different type of beam quality parameter in small beams was studied, namely the dose-area product ratio, or DAPR 20,10 . With this method, the measurement of a dose-area product (DAP) using a large-area plane-parallel chamber (LAC) eliminates the uncertainties in detector positioning and volume averaging that are present when using a point detector. In this study, the properties of the DAPR 20,10 of a cone-collimated 6 MV photon beam were investigated using Monte Carlo (MC) calculations and the obtained values were compared to measurements obtained using two LAC detectors, PTW Type 34073 and PTW Type 34070. In addition, the possibility of determining the DAP using EBT3 film and a Razor diode detector was studied. The determination of the DAPR 20,10 value was found to be feasible in external small-beam radiotherapy using cone-collimated beams with diameters from 4-40 mm, based on the results of the two LACs, the MC calculations and the Razor diode. The measurements indicated a constant DAPR 20,10 value for fields 20-40 mm in diameter, with a maximum relative change of 0.6%, but an increase of 7.0% for fields from 20-4 mm in diameter for the PTW Type 34070 chamber. Simulations and measurements showed an increase of DAPR 20,10 with increasing LAC size or dose integral area for the studied 4-40 mm cone-collimated 6 MV photon beams. This has the consequence that there should be a reference to the size of the used LAC active area or the DAP integration area with the reported DAPR 20,10 value.
Preoperative localization of intracranial lesions with MRI using marking pills.
Shibata, Sumiya; Kunieda, Takeharu; Adachi, Hidemitsu; Ueno, Yasushi; Kohara, Nobuo; Sakai, Nobuyuki
2011-12-01
To describe a simple technique for preoperative surface localization of intracranial lesions. 11 pills in total, including Alfarol (alfacalcidol) capsules, were affixed to a phantom with adhesive tape and a MRI scan was performed. The visibility of the pills and any spatial errors in determining their locations were evaluated. Between June 2006 and April 2009, we employed Alfarol capsules as a skin marker in MRI in clinical surgical cases. Alfarol capsules, whose actual size is 5.6 mm in diameter, were identified as a hyperintense spot at a size of 4.2, 4.2, and 4.5mm in diameter in T1-weighted, T2-weighted, and FLAIR (fluid attenuated inversion recovery) sequence images, respectively. The size discrepancies were within 1.4 mm. The average spatial errors were 0.7, 0.6, and 0.7 mm in T1-weighted, T2-weighted, and FLAIR sequence images, respectively. Other pills were not identified in the MRI scans. During this 35-month period, 8 patients underwent preoperative MRI-guided localization at our institution. There were 5 men and 3 women in whom 8 biopsies were performed. In all cases, the result of the biopsy was positive and useful for the treatment that followed. No perioperative complications were encountered. Alfarol capsule can be used as an external skin marker. Our simple and inexpensive method is a useful addition to preoperative evaluation of superficial intracranial lesions. Copyright © 2011 Elsevier B.V. All rights reserved.
Two-stage controlled release system possesses excellent initial and long-term efficacy.
Luo, Jian; Jing, Tong-Fang; Zhang, Da-Xia; Zhang, Xian-Peng; Li, Beixing; Liu, Feng
2018-05-24
In this work, a series of polyurea-based lambda-cyhalothrin-loaded microcapsules (MCs) with three different size distributions (average diameters of 1.35 μm, MC-S; 5.13 μm, MC-M; and 21.48 μm, MC-L) were prepared and characterized. The results indicated that MCs with a smaller particle size distribution had a faster release rate and excellent initial efficacy against pests. MC-L had a remarkably slow incipient release rate, outstanding photostability and better later-stage efficacy than that of the other tested MCs. The results clarified that the diameter distribution of MCs is the key factor in determining the release property and bioactivity of the MC formulations. Subsequently, the binary mixture MC formulations of MC(+M), MC(S+L) and MC(M+L) were obtained by mixing MC-S, MC-M or MC-L at 1:1 to establish a two-stage release system utilized for foliar application situations. Greenhouse and field experiments showed that MC(S+L) provided an optimal efficacy, and its effective duration was much longer than that of the emulsifiable concentrate (EC) group. Therefore, the release system established in this study was simple and workable for regulating the initial and long-term efficacy by adjusting the particle size distribution; in addition, this system has potential applications in other fields such as drug delivery devices. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kawasaki, Shin-Ichiro; Sue, Kiwamu; Ookawara, Ryuto; Wakashima, Yuichiro; Suzuki, Akira
2015-12-01
In the synthesis of metal oxide fine particles by continuous supercritical hydrothermal method, the particle characteristics are greatly affected by not only the reaction conditions (temperature, pressure, residence time, concentration, etc.), but also the heating rate from ambient to reaction temperature. Therefore, the heating method by direct mixing of starting solution at room temperature with supercritical water is a key technology for the particle production having smaller size and narrow distribution. In this paper, mixing engineering study through comparison between conventional T-shaped mixers and recently developed swirl mixers was carried out in the hydrothermal synthesis of NiO nanoparticles from Ni(NO3)2 aqueous solution at 400 °C and 30 MPa. Inner diameter in the mixers and total flow rates were varied. Furthermore, the heating rate was calculated by computational fluid dynamics (CFD) simulation. Relationship between the heating rate and the average particle size were discussed. It was clarified that the miniaturization of mixer inner diameter and the use of the swirl flow were effective for improving mixing performance and contributed to produce small and narrow distribution particle under same experimental condition of flow rate, temperature, pressure, residence time, and concentration of the starting materials. We have focused the mixer optimization due to a difference in fluid viscosity.
Pinkerton, Nathalie M.; Gindy, Marian E.; Calero-DdelC, Victoria L.; Wolfson, Theodore; Pagels, Robert F.; Adler, Derek; Gao, Dayuan; Li, Shike; Wang, Ruobing; Zevon, Margot; Yao, Nan; Pacheco, Carlos; Therien, Michael J.; Rinaldi, Carlos; Sinko, Patrick J.
2015-01-01
MRI and NIR-active, multi-modal Composite NanoCarriers (CNCs) are prepared using a simple, one-step process, Flash NanoPrecipitation (FNP). The FNP process allows for the independent control of the hydrodynamic diameter, co-core excipient and NIR dye loading, and iron oxide-based nanocrystal (IONC) content of the CNCs. In the controlled precipitation process, 10 nm IONCs are encapsulated into poly(ethylene glycol) stabilized CNCs to make biocompatible T2 contrast agents. By adjusting the formulation, CNC size is tuned between 80 and 360 nm. Holding the CNC size constant at an intensity weighted average diameter of 99 ± 3 nm (PDI width 28 nm), the particle relaxivity varies linearly with encapsulated IONC content ranging from 66 to 533 mM-1s-1 for CNCs formulated with 4 to 16 wt% IONC. To demonstrate the use of CNCs as in vivo MRI contrast agents, CNCs are surface functionalized with liver targeting hydroxyl groups. The CNCs enable the detection of 0.8 mm3 non-small cell lung cancer metastases in mice livers via MRI. Incorporating the hydrophobic, NIR dye PZn3 into CNCs enables complementary visualization with long-wavelength fluorescence at 800 nm. In vivo imaging demonstrates the ability of CNCs to act both as MRI and fluorescent imaging agents. PMID:25925128
The population of natural Earth satellites
NASA Astrophysics Data System (ADS)
Granvik, Mikael; Vaubaillon, Jeremie; Jedicke, Robert
2012-03-01
We have for the first time calculated the population characteristics of the Earth’s irregular natural satellites (NESs) that are temporarily captured from the near-Earth-object (NEO) population. The steady-state NES size-frequency and residence-time distributions were determined under the dynamical influence of all the massive bodies in the Solar System (but mainly the Sun, Earth, and Moon) for NEOs of negligible mass. To this end, we compute the NES capture probability from the NEO population as a function of the latter’s heliocentric orbital elements and combine those results with the current best estimates for the NEO size-frequency and orbital distribution. At any given time there should be at least one NES of 1-m diameter orbiting the Earth. The average temporarily-captured orbiter (TCO; an object that makes at least one revolution around the Earth in a co-rotating coordinate system) completes (2.88 ± 0.82) rev around the Earth during a capture event that lasts (286 ± 18) d. We find a small preference for capture events starting in either January or July. Our results are consistent with the single known natural TCO, 2006 RH120, a few-meter diameter object that was captured for about a year starting in June 2006. We estimate that about 0.1% of all meteors impacting the Earth were TCOs.
NASA Technical Reports Server (NTRS)
Ni, Xiang; Liu, Chuntao; Zhang, Qinghong; Cecil, Daniel J.
2016-01-01
A 16-yr record of hail reports over the southeast US and from weather stations in China are collocated with Precipitation Features (PF) derived from the Tropical Rainfall Measurement Mission (TRMM) radar and passive microwave observations. While U.S. hail reports are dominated by cases with hail size greater than 19 mm, hail reports in China mostly include diameters of 1-10 nm and mostly occur over the Tibetan Plateau. The fraction of PFs collocated with hail reports (hail PFs) reaches 3% in the plains of the U.S. In China, the fraction is higher in high elevation regions than low elevation regions. Hail PFs in the U.S. show lower brightness temperatures, higher lightning flash rates, stronger maximum reflectivity, and higher echo tops than those in China, consistent with the larger hail diameters in the U.S. reports. The average near surface maximum reflectivity of hail PFs at higher elevations (greater than or equal to 2000 m) in China is about 5 dB smaller than those at low elevations. Larger hail is reported with PFs having stronger maximum reflectivity above 6 km, though the median of maximum reflectivity values at levels below 5 km is close among the storms with large and small hail sizes.
Endoscopic mucosal resection for middle and large colorectal polyps with a double-loop snare.
Yoshida, Naohisa; Saito, Yutaka; Hirose, Ryohei; Ogiso, Kiyoshi; Inada, Yutaka; Yagi, Nobuaki; Naito, Yuji; Otake, Yosuke; Nakajima, Takeshi; Matsuda, Takahisa; Yanagisawa, Akio; Itoh, Yoshito
2014-01-01
This study aimed to analyze the endoscopic mucosal resection (EMR) with a novel uniquely shaped, double-loop snare (Dualoop, Medico's Hirata Inc., Tokyo, Japan) for colorectal polyps. This was a clinical trial conducted in two referral centers, Kyoto Prefectural University of Medicine and National Cancer Center Hospital in Japan. First, the firmness of various snares including 'Dualoop' was experimentally analyzed with a pressure gauge. Five hundred and eighty nine consecutive polyps that underwent EMR with 'Dualoop' were compared to 339 polyps with the standard round snare. Lesion characteristics, en bloc resection, and complications were analyzed. 'Dualoop' had the most firmness among the various snares. The average tumor size was 9.3 mm (5-30), and en bloc resection was achieved in 95.4%. The rate of en bloc resection for middle polyps 15-19 mm in diameter was significantly higher with the 'Dualoop' than that with the round snare (97.9 vs. 80.0%, p < 0.05). The rate of en bloc resection was 64.7% for large polyps ≥20 mm in diameter using 'Dualoop'. Higher age, larger tumor size, and superficial polyps were associated with the failure of en bloc resection. EMR with 'Dualoop' was effective for resecting both middle and large polyps en-bloc. © 2014 S. Karger AG, Basel.
Jin, Hei-Ying; Leng, Qiang
2015-01-14
To determine the accuracy of endoscopic polyp size measurements using disposable graduated biopsy forceps (DGBF). Gradations accurate to 1 mm were assessed with the wire of disposable graduated biopsy forceps. When a polyp was noted, endoscopists determined the width of the polyp; then, the graduated biopsy forceps was inserted and the largest diameter of the tumor was measured. After excision, during surgery or endoscopy, the polyp was measured using the vernier caliper. One hundred and thirty-three colorectal polyps from 119 patients were studied. The mean diameter, by post-polypectomy measurement, was 0.92 ± 0.69 cm; 83 were < 1 cm, 36 were between 1 and 2 cm, and 14 were > 2 cm. The mean diameter, by visual estimation, was 1.15 ± 0.88 cm; compared to the actual size measured using vernier calipers, the difference was statistically significant. The mean diameter measured using the DGBF was 0.93 ± 0.68 cm; compared to the actual size measured using vernier calipers, this difference was not statistically significant. The ratio between the mean size estimated by visual estimation and the actual size was significantly different from that between the mean size estimated using the DGBF and the actual size (1.26 ± 0.30 vs 1.02 ± 0.11). The accuracy of polyp size estimation was low by visual assessment; however, it improved when the DGBF was used.
Heat generated during seating of dental implant fixtures.
Flanagan, Dennis
2014-04-01
Frictional heat can be generated during seating of dental implants into a drill-prepared osteotomy. This in vitro study tested the heat generated by implant seating in dense bovine mandible ramus. A thermocouple was placed approximately 0.5 mm from the rim of the osteotomy during seating of each dental implant. Four diameters of implants were tested. The average temperature increases were 0.075°C for the 5.7-mm-diameter implant, 0.97°C for the 4.7-mm-diameter implant, 1.4°C for the 3.7-mm-diameter implant, and 8.6°C for the 2.5-mm-diameter implant. The results showed that heat was indeed generated and a small temperature rise occurred, apparently by the friction of the implant surface against the fresh-cut bone surface. Bone is a poor thermal conductor. The titanium of the implant and the steel of the handpiece are much better heat conductors. Titanium may be 70 times more heat conductive than bone. The larger diameter and displacement implant may act as a heat sink to draw away any heat produced from the friction of seating the implant at the bone-implant interface. The peak temperature duration was momentary, and not measured, but this was approximately less than 1 second. Except for the 2.5-mm-diameter implants, the temperature rises and durations were found to be below those previously deemed to be detrimental, so no clinically significant osseous damage would be expected during dental implant fixture seating of standard and large-diameter-sized implants. A 2.5-mm implant may generate detrimental heat during seating in nonvital bone, but this may be clinically insignificant in vital bone. The surface area and thermal conductivity are important factors in removing generated heat transfer at the bone-implant interface. The F value as determined by analysis of variance was 69.22, and the P value was less than .0001, demonstrating significant differences between the groups considered as a whole.
NASA Astrophysics Data System (ADS)
Mishchenko, I.; Chuev, M.; Kubrin, S.; Lastovina, T.; Polyakov, V.; Soldatov, A.
2018-05-01
Alternative explanation to the effect of disappearance of the Morin transition on hematite nanoparticles with their size decreasing is proposed basing on an idea of the predominant role of the shape anisotropy for nanosize particles. Three types of the magnetic structure of hematite nanoparticles with various sizes are found by Mössbauer spectroscopy: coexistence of the well-pronounced antiferromagnetic and weakly ferromagnetic phases for particles with average diameters of about 55 nm, non-uniform distribution of the magnetization axes which concentrate on the vicinity of the basal plane (111) for prolonged particles with cross sections of about 20 nm, and uniform distribution of the easy axes in regard to the crystalline directions for 3-nm particles. Description of the temperature evolution of experimental data within novel model of the magnetic dynamics for antiferromagnetic particles which accounts the exchange, relativistic, and anisotropy interactions is provided, and the structural as well as energy characteristics of the studied systems are reconstructed.
Antiviral activity of silver nanoparticle/chitosan composites against H1N1 influenza A virus
NASA Astrophysics Data System (ADS)
Mori, Yasutaka; Ono, Takeshi; Miyahira, Yasushi; Nguyen, Vinh Quang; Matsui, Takemi; Ishihara, Masayuki
2013-02-01
Silver nanoparticle (Ag NP)/chitosan (Ch) composites with antiviral activity against H1N1 influenza A virus were prepared. The Ag NP/Ch composites were obtained as yellow or brown floc-like powders following reaction at room temperature in aqueous medium. Ag NPs (3.5, 6.5, and 12.9 nm average diameters) were embedded into the chitosan matrix without aggregation or size alternation. The antiviral activity of the Ag NP/Ch composites was evaluated by comparing the TCID50 ratio of viral suspensions treated with the composites to untreated suspensions. For all sizes of Ag NPs tested, antiviral activity against H1N1 influenza A virus increased as the concentration of Ag NPs increased; chitosan alone exhibited no antiviral activity. Size dependence of the Ag NPs on antiviral activity was also observed: antiviral activity was generally stronger with smaller Ag NPs in the composites. These results indicate that Ag NP/Ch composites interacting with viruses exhibit antiviral activity.
Doppler lidar power, aperture diameter, and FFT size trade-off study
NASA Astrophysics Data System (ADS)
Chester, David B.; Budge, Scott E.
2017-05-01
In the design or selection of a Doppler lidar instrument for a spacecraft landing system, it is important to evaluate the balance between performance requirements and cost, weight, and power consumption. Leveraging the capability of LadarSIM, a trade-off study was performed to evaluate the interaction between the laser transmission power, aperture diameter, and FFT size in a Doppler lidar system. For this study the probabilities of detection and false alarm were calculated using LadarSIM to simulate FMCW lidar systems with varying power, aperture diameter, and FFT size. This paper reports the results of this trade-off study.
Airborne fungi in low and high allergic prevalence child care centers
NASA Astrophysics Data System (ADS)
Zuraimi, M. S.; Fang, L.; Tan, T. K.; Chew, F. T.; Tham, K. W.
Fungi exposure has been linked to asthma and allergies among children. To determine the association between fungal exposure and wheeze and rhinitis symptoms, we examined concentrations of culturable indoor and outdoor fungi of various aerodynamic sizes in low and high allergic prevalence child care centers (CCCs) in Singapore. Environmental parameters were also performed for air temperature, relative humidity and ventilation rates, while information on CCC characteristics was collected via an inspection. Most commonly recovered fungi were Penicillium, Aspergillus, Geotrichum, Cladosporium and sterile mycelia with Geotrichum and sterile mycelia amounting to an average of 71.5% of the total airborne culturable fungi studied. Indoor and outdoor total culturable fungi concentrations and those in the size range of 1.1-3.3 μm were significantly higher in high allergic prevalence CCCs. When fungal types/genera were compared, indoor and outdoor Geotrichum and sterile mycelia of aerodynamic sizes 1.1-3.3 μm were found to be significantly elevated in high allergic prevalence CCCs. Indeed, average geometric mean diameters ( Dg, ave) of indoor and outdoor culturable fungi were consistently smaller in CCCs with high prevalence of allergies than those with low prevalence. We found significant associations of higher fungal concentrations, especially those with smaller aerodynamic sizes in CCCs situated near parks. There were no differences in fungal levels between CCCs with respect to their dampness profile mainly due to high CCC ventilation rates. Since particle size is a factor that determines where a fungi particle deposits in the respiratory tract, this study provides useful information in the etiology of wheeze and rhinitis symptoms among the CCC attending children.
The importance of “going nano” for high power battery materials
NASA Astrophysics Data System (ADS)
Bresser, Dominic; Paillard, Elie; Copley, Mark; Bishop, Peter; Winter, Martin; Passerini, Stefano
2012-12-01
The electrochemical performance of spinel Li4Ti5O12 (LTO) nanoparticles synthesized by flame spray pyrolysis with an average diameter of approximately 20-30 nm is reported in this manuscript and compared with that of micro-sized LTO particles (1-2 μm) formed by a thermal post-treatment of the nanoparticles. The significantly advanced high rate capability of nano-sized LTO is evidenced by the results from the galvanostatic tests with applied current densities of up to 17.5 A g-1, corresponding to a full (dis-)charge of the cell within less than 40 s. For nano-sized LTO, specific capacities of 115 and 70 mAh g-1 were obtained for applied rates of 10 C and 100 C, respectively, thus confirming the essential influence of particle size of lithium titanate on its high rate capability and practical power density. Moreover, a capacity retention of around 94.8% was observed after 1000 cycles at 10 C, presenting LTO nanoparticles synthesized by FSP as highly promising anode material for high power lithium-ion battery applications.
Controlling Release Kinetics of PLG Microspheres Using a Manufacturing Technique
NASA Astrophysics Data System (ADS)
Berchane, Nader
2005-11-01
Controlled drug delivery offers numerous advantages compared with conventional free dosage forms, in particular: improved efficacy and patient compliance. Emulsification is a widely used technique to entrap drugs in biodegradable microspheres for controlled drug delivery. The size of the formed microspheres has a significant influence on drug release kinetics. Despite the advantages of controlled drug delivery, previous attempts to achieve predetermined release rates have seen limited success. This study develops a tool to tailor desired release kinetics by combining microsphere batches of specified mean diameter and size distribution. A fluid mechanics based correlation that predicts the average size of Poly(Lactide-co-Glycolide) [PLG] microspheres from the manufacturing technique, is constructed and validated by comparison with experimental results. The microspheres produced are accurately represented by the Rosin-Rammler mathematical distribution function. A mathematical model is formulated that incorporates the microsphere distribution function to predict the release kinetics from mono-dispersed and poly-dispersed populations. Through this mathematical model, different release kinetics can be achieved by combining different sized populations in different ratios. The resulting design tool should prove useful for the pharmaceutical industry to achieve designer release kinetics.
Size-dependent modification of asteroid family Yarkovsky V-shapes
NASA Astrophysics Data System (ADS)
Bolin, B. T.; Morbidelli, A.; Walsh, K. J.
2018-04-01
Context. The thermal properties of the surfaces of asteroids determine the magnitude of the drift rate cause by the Yarkovsky force. In the general case of Main Belt asteroids, the Yarkovsky force is indirectly proportional to the thermal inertia, Γ. Aim. Following the proposed relationship between Γ and asteroid diameter D, we find that asteroids' Yarkovsky drift rates might have a more complex size dependence than previous thought, leading to a curved family V-shape boundary in semi-major axis, a, vs. 1/D space. This implies that asteroids are drifting faster at larger sizes than previously considered decreasing on average the known ages of asteroid families. Methods: The V-Shape curvature is determined for >25 families located throughout the Main Belt to quantify the Yarkovsky size-dependent drift rate. Results: We find that there is no correlation between family age and V-shape curvature. In addition, the V-shape curvature decreases for asteroid families with larger heliocentric distances suggesting that the relationship between Γ and D is weaker in the outer MB possibly due to homogenous surface roughness among family members.
Synthesis, self-assembly, and properties of Mn doped ZnO nanoparticles.
Barick, K C; Bahadur, D
2007-06-01
We report here a novel process to prepare Mn doped ZnO nanoparticles by a soft chemical route at low temperature. The synthesis process is based on the hydrolysis of zinc acetate dihydrate and manganese acetate tetrahydrate heated under reflux to 160-175 degrees C using diethylene glycol as a solvent. X-ray diffraction analysis reveals that the Mn doped ZnO crystallizes in a wurtzite structure with crystal size of 15-25 nm. These nano size crystallites of Mn doped ZnO self-organize into polydisperse spheres in size ranging from 100-400 nm. Transmission Electron Microscopy image also shows that each sphere is made up of numerous nanocrystals of average diameter 15-25 nm. By means of X-ray photoelectron spectroscopy and electron spin resonance spectroscopy, we determined the valence state of Mn ions as 2+. These nanoparticles were found to be ferromagnetic at room temperature. Monodisperse porous spheres (approximately 250 nm) were obtained by size selective separation technique and then self-assembled in a closed pack periodic array through sedimentation with slow solvent evaporation, which gives strong opalescence in visible region.
The Effect of Density on the Height-Diameter Relationship
Boris Zeide; Curtis Vanderschaaf
2002-01-01
Using stand density along with mean diameter to predict average height increases the proportion of explained variance. This result, obtained from permanent plots established in a loblolly pine plantation thinned to different levels, makes sense. We know that due to competition, trees with the same diameter are taller in denser stands. Diameter and density are not only...
Growth of nanostructures with controlled diameter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pfefferle, Lisa; Haller, Gary; Ciuparu, Dragos
2009-02-03
Transition metal-substituted MCM-41 framework structures with a high degree of structural order and a narrow pore diameter distribution were reproducibly synthesized by a hydrothermal method using a surfactant and an anti-foaming agent. The pore size and the mesoporous volume depend linearly on the surfactant chain length. The transition metals, such as cobalt, are incorporated substitutionally and highly dispersed in the silica framework. Single wall carbon nanotubes with a narrow diameter distribution that correlates with the pore diameter of the catalytic framework structure were prepared by a Boudouard reaction. Nanostructures with a specified diameter or cross-sectional area can therefore be predictablymore » prepared by selecting a suitable pore size of the framework structure.« less
In the early 1970s, it was understood that combustion particles were formed mostly in sizes below 1 um diameter, and windblown dust was suspended in sizes mostly above 1 um diameter. However, particle size distribution was thought of as a single mode. Particles were thought to f...
Size effects on miniature Stirling cycle cryocoolers
NASA Astrophysics Data System (ADS)
Yang, Xiaoqin; Chung, J. N.
2005-08-01
Size effects on the performance of Stirling cycle cryocoolers were investigated by examining each individual loss associated with the regenerator and combining these effects. For the fixed cycle parameters and given regenerator length scale, it was found that only for a specific range of the hydrodynamic diameter the system can produce net refrigeration and there is an optimum hydraulic diameter at which the maximum net refrigeration is achieved. When the hydraulic diameter is less than the optimum value, the regenerator performance is controlled by the pressure drop loss; when the hydraulic diameter is greater than the optimum value, the system performance is controlled by the thermal losses. It was also found that there exists an optimum ratio between the hydraulic diameter and the length of the regenerator that offers the maximum net refrigeration. As the regenerator length is decreased, the optimum hydraulic diameter-to-length ratio increases; and the system performance is increased that is controlled by the pressure drop loss and heat conduction loss. Choosing appropriate regenerator characteristic sizes in small-scale systems are more critical than in large-scale ones.
NASA Astrophysics Data System (ADS)
Roth, Tanja; Sprenger, Lisa; Odenbach, Stefan; Häfeli, Urs O.
2018-04-01
Microfluidic spirals are able to focus non-spherical microparticles in diluted suspension due to the Dean effect. A secondary flow establishes in a curved channel, consisting of two counter-rotating vortices, which transport particles to an equilibrium position near the inner wall of the channel. The relevant size parameter, which is responsible for successful focusing, is the ratio between the particle diameter of a sphere and the hydraulic diameter, which is a characteristic of the microfluidic spiral. A non-spherical particle has not one but several different size parameters. This study investigated the minor and major axes, the equivalent spherical diameter, and the maximal rotational diameter as an equivalent to the spherical diameter. Using a polydimethylsiloxane (PDMS)-based microfluidic device with spirals, experiments were conducted with artificial peanut-shaped and ellipsoidal particles sized between 3 and 9 μm as well as with the bacteria Bacillus subtilis. Our investigations show that the equivalent spherical diameter, the major axis, and the maximal rotational diameter of a non-spherical particle can predict successful focusing. The minor axis is not suitable for this purpose. Non-spherical particles focused when the ratio of their equivalent spherical diameter to the hydraulic diameter of the channel was larger than 0.07. The particles also focused when the ratio between the maximal rotational diameter or the major axis and the hydraulic diameter was larger than 0.01. These results may help us to separate non-spherical biological particles, such as circulating tumor cells or pathogenic bacteria, from blood in future experimental studies.
Relationship between the Apical Preparation Diameter and the Apical Seal: An In Vitro Study.
Laslami, Kaoutar; Dhoum, Sara; El Harchi, Amine; Benkiran, Iman
2018-01-01
The aim of the study is to define the relationship between the apical preparation diameter and the apical sealing ability to highlight the importance of the preservation of the diameter and the original position of the apical foramen. 50 extracted maxillary incisors were randomly allocated into three groups of 15 teeth each (n = 15) according to the apical preparation size: Group 1: finishing file F1 corresponding to size 20 reached the working length (ProTaper Universal system Dentsply®); Group 2: prepared up to size 30 corresponding to finishing file F30; Group 3: prepared up to size 50 corresponding to finishing file F5. Five teeth were assigned to positive and negative control groups. After the filling of the root canals, the teeth were isolated and immersed in a dye solution, then cut longitudinally, photographed, and the dye penetration were calculated using a computer software. Comparison of the three different apical preparation sizes showed no statistically significant differences regarding the apical microleakage. The most important value of the dye penetration was observed in the group with the largest apical diameter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheng-Ling, Jan; Hwang, Betau; Lee, P.-C.
Purpose: Accurate evaluation of the size, location and adjacent structure of an atrial septal defect (ASD) is very important in the selection of patients for further management. We directly compared the utility of transthoracic echocardiography, angiocardiography, balloon sizing, and intracardiac ultrasound (ICUS) in the detection of ASD.Methods: Twenty-one children underwent an ICUS study of ASD after routine clinical and laboratory studies. All patients had received transthoracic echocardiography (TTE), cardiac catheterization, cineangiography, and balloon sizing before the ICUS to evaluate the ASD.Results: There was a significant correlation between the ICUS-derived ASD diameter and the other methods (p < 0.001). The balloon-sizingmore » diameter was estimated by the equation: TTE diameter x 1.09 + 3.9 mm. There was a good correlation between the predicted and measured balloon-sizing diameter (r = 0.963; p < 0.001).Conclusion: It is worthwhile spending a few minutes to perform ICUS during cardiac catheterization since it will provide more detailed information on and high resolution images of atrial septal morphology, especially for patients undergoing transcatheter closure by device.« less
Range camera on conveyor belts: estimating size distribution and systematic errors due to occlusion
NASA Astrophysics Data System (ADS)
Blomquist, Mats; Wernersson, Ake V.
1999-11-01
When range cameras are used for analyzing irregular material on a conveyor belt there will be complications like missing segments caused by occlusion. Also, a number of range discontinuities will be present. In a frame work towards stochastic geometry, conditions are found for the cases when range discontinuities take place. The test objects in this paper are pellets for the steel industry. An illuminating laser plane will give range discontinuities at the edges of each individual object. These discontinuities are used to detect and measure the chord created by the intersection of the laser plane and the object. From the measured chords we derive the average diameter and its variance. An improved method is to use a pair of parallel illuminating light planes to extract two chords. The estimation error for this method is not larger than the natural shape fluctuations (the difference in diameter) for the pellets. The laser- camera optronics is sensitive enough both for material on a conveyor belt and free falling material leaving the conveyor.
Preparation and antibacterial properties of Ag@polydopamine/graphene oxide sheet nanocomposite
NASA Astrophysics Data System (ADS)
Zhou, Hao; Liu, Yunfang; Chi, Weidong; Yu, Changyuan; Yu, Yingjie
2013-10-01
Immobilization of silver nanoparticles (Ag NPs) on poly-dopamine (PDA) functionalized graphene oxide sheets (GOSs) were carried out by an easy in situ reduction method. The PDA layer was coated on the surface of the GOSs via the self-polymerization of dopamine under atmosphere condition. The PDA layer not only works as the chemisorption and reduction sites for silver ions to form Ag NPs but also stabilizes them. High-resolution transmission electron microscopy observation shows that the average size of the Ag NPs anchored on the PDA/GOS composite is about 2.8 nm. The inhibition zone diameter of the Ag@PDA/GOS nanocomposite is about 23.7 mm, whereas said diameter of the Ag NPs is only 18.5 mm. The minimum bactericidal concentration of the Ag@PDA/GOS nanocomposite is about 25 μg/ml that is only half of said concentration of the Ag NPs. The Ag@PDA/GOS nanocomposite exhibits an excellent antibacterial property.
NASA Technical Reports Server (NTRS)
Mohamadinejad, H.; Knox, J. C.; Smith, J. E.; Croomes, Scott (Technical Monitor)
2001-01-01
The experimental results of CO2 adsorption and desorption in a packed column indicated that the concentration wave front at the center of the packed column differs from those which are close to the wall of column filled with adsorbent material even though the ratio of column diameter to the particle size is greater than 20. The comparison of the experimental results with one dimensional model of packed column shows that in order to simulate the average breakthrough in a packed column a two dimensional (radial and axial) model of packed column is needed. In this paper the mathematical model of a non-slip flow through a packed column with 2 inches in diameter and 18 inches in length filled with 5A zeolite pellets is presented. The comparison of experimental results of CO2 absorption and desorption for the mixed and central breakthrough of the packed column with numerical results is also presented.
Wilson, David R; Green, Jordan J
2017-01-01
Nanoparticle tracking analysis (NTA) is a recently developed nanoparticle characterization technique that offers certain advantages over dynamic light scattering for characterizing polyplex nanoparticles in particular. Dynamic light scattering results in intensity-weighted average measurements of nanoparticle characteristics. In contrast, NTA directly tracks individual particles, enabling concentration measurements as well as the direct determination of number-weighted particle size and zeta-potential. A direct number-weighted assessment of nanoparticle characteristics is particularly useful for polydisperse samples of particles, including many varieties of gene delivery particles that can be prone to aggregation. Here, we describe the synthesis of poly(beta-amino ester)/deoxyribonucleic acid (PBAE/DNA) polyplex nanoparticles and their characterization using NTA to determine hydrodynamic diameter, zeta-potential, and concentration. Additionally, we detail methods of labeling nucleic acids with fluorophores to assess only those polyplex nanoparticles containing plasmids via NTA. Polymeric gene delivery of exogenous plasmid DNA has great potential for treating a wide variety of diseases by inducing cells to express a gene of interest.
Controle de la morphologie d'hydrogels poreux a partir de structures polymeres
NASA Astrophysics Data System (ADS)
Esquirol, Anne-Laure
This master thesis presents a new fabrication method to prepare hydrogels with fully interconnected and tunable macropore networks prepared with co-continuous polymer blends. The main contributions are: (1) a hydrogel fabrication process providing a high control over the average pore size diameter, their volume fraction and their interconnectivity; (2) the microstructural characterization of porous hydrogels with new techniques such as X-ray microtomography and (3) the preparation of porous gels with industrial equipment such as extruders and injection molding presses. The development and improvement of methods and techniques to prepare porous polymers and porous gels have been intensive areas of research in materials science over the past 20 years because of their potential use in fields as diverse as high performance membranes and filtration devices, supports for catalysis and biochemical reactions, encapsulating devices for drug release, and scaffolds for cells seeding and proliferation. For this last application, in tissue engineering, some typical parameters related to porosity must be rigorously controlled: (1) the average pore size diameter; (2) the pore volume fraction; (3) the pore interconnectivity. Porous hydrogels are excellent candidates due to their similarities with the extracellular matrix (composition, mechanical properties and diffusion properties). A certain number of methods and techniques have been developed and studied to prepare gels comprising microstructured 3-D networks of (more or less) interconnected pores (also called sometimes microfluidic gels or (macro)porous gels). Poly(L-lactide) (PLA) porous materials were realized from immiscible and co-continuous binary blends of polystyrene/poly(L-lactide) (PS/PLA) at 50/50 %vol prepared by different methods : (1) internal mixer (cubic samples with 0.8 mm sides) and (2) extrusion followed by injection molding which allows the fabrication of bars with superior dimensions (0.95 cm x 1.25 cm x 6.3 cm). Quiescent annealing of the binary blends was performed at 190 °C to tune the characteristic dimensions of the co-continuous morphology: (1) 0, 10, 30, 60 and 90 min for cubic samples and (2) 0, 10, 20 and 30 min for bars. Afterwards, the PLA phase has been isolated by a specific solvent extraction of the PS phase to obtain porous PLA molds. Gravimetric analysis have demonstrated a co-continuity superior to 95% for cubic samples and superior to 85% for the bars. This morphology was analyzed by scanning electron microscopy (SEM) for each annealing time (for the cubic samples). Image analysis performed on the SEM micrographs have demonstrated that the average pore diameter can range from 3 mum to over 400 mum and that the specific interfacial area ranges from 5800 cm-1 to 45 cm-1, for annealing times going from 0 min to 90 min). The porosity of the bars was observed by X-ray microtomography and shows that the average pore diameter ranges from 10 mum to 500 mum (annealing from 10 min to 30 min). Solutions of agar or alginate were subsequently injected into the PLA porous molds by using a manual injection system, followed by an in situ gelification. Visual inspections and optical microscope observations show a complete injection for molds with average pore sizes over 20 mum (cubic samples) and over 300 mum (for bars). These assumptions are also supported by the gels morphology characterization. The second polymer phase (PLA) was subsequently dissolved using a second selective solvent, leaving only the porous gel structures. X-ray microtomography analysis, which provide 2-D and 3-D images, have demonstrated that the morphologies of the porous gels are similar to the PLA molds microstructures. For example, porous gels prepared with cubic PLA molds annealed during 60 min, show an average pore size of about 285 mum (as compared to 200 mum for the PLA molds) and a specific interfacial area of 70 cm -1 (as compared to 100 cm-1 for the PLA molds). Similar results were obtained for the porous gels prepared with the porous PLA bars (qualitative observation). The effectiveness of two sterilization methods has been proven on nutrient agar (NA) and "Brain Heart Infusion" (BHI) with no bacterial colonies apparition. The first method is the freeze-drying followed by an oven treatment at 120 °C in a sterile environment. The porous gel morphology was characterized by X-ray microtomography before and after freeze-drying, and after rehydration, demonstrating the conservation of the macroscopic dimensions of the gels, of their morphologies and porosities. The second method is the successive baths in an ethanol solution. Finally mechanical compression tests have shown that porous gels, as can be expected, have a lower compressive resistance as compared to non-porous hydrogels. (Abstract shortened by UMI.).
Thermal conductivity measurements of particulate materials under Martian conditions
NASA Technical Reports Server (NTRS)
Presley, M. A.; Christensen, P. R.
1993-01-01
The mean particle diameter of surficial units on Mars has been approximated by applying thermal inertia determinations from the Mariner 9 Infrared Radiometer and the Viking Infrared Thermal Mapper data together with thermal conductivity measurement. Several studies have used this approximation to characterize surficial units and infer their nature and possible origin. Such interpretations are possible because previous measurements of the thermal conductivity of particulate materials have shown that particle size significantly affects thermal conductivity under martian atmospheric pressures. The transfer of thermal energy due to collisions of gas molecules is the predominant mechanism of thermal conductivity in porous systems for gas pressures above about 0.01 torr. At martian atmospheric pressures the mean free path of the gas molecules becomes greater than the effective distance over which conduction takes place between the particles. Gas particles are then more likely to collide with the solid particles than they are with each other. The average heat transfer distance between particles, which is related to particle size, shape and packing, thus determines how fast heat will flow through a particulate material.The derived one-to-one correspondence of thermal inertia to mean particle diameter implies a certain homogeneity in the materials analyzed. Yet the samples used were often characterized by fairly wide ranges of particle sizes with little information about the possible distribution of sizes within those ranges. Interpretation of thermal inertia data is further limited by the lack of data on other effects on the interparticle spacing relative to particle size, such as particle shape, bimodal or polymodal mixtures of grain sizes and formation of salt cements between grains. To address these limitations and to provide a more comprehensive set of thermal conductivities vs. particle size a linear heat source apparatus, similar to that of Cremers, was assembled to provide a means of measuring the thermal conductivity of particulate samples. In order to concentrate on the dependence of the thermal conductivity on particle size, initial runs will use spherical glass beads that are precision sieved into relatively small size ranges and thoroughly washed.
[Perforated duodenal ulcer: benefits and risks of laparoscopic repair].
Lunevicius, Raimundas; Morkevicius, Matas
2004-01-01
Laparoscopic perforated duodenal ulcer repair is a minimally invasive technique. Just like any other type of surgery, the laparoscopic approach carries operative risks in itself. The primary goal of this article is to describe the possible risk factors in laparoscopic duodenal ulcer repair. The secondary goal is to clarify benefits of the laparoscopic surgery. The Medline/Pubmed database was used; 73 articles were analyzed and evaluated. Six retrospective and nine prospective studies are summarized. The retrospective studies' results are as follows: total complication rate is 7-28% (average--16%); conversion rate is 6-30% (average--18%); postoperative mortality rate is 0-20% (average--6%); and average hospital stay is 6-17 days (average--8 days). The results of the prospective studies are the following: total complication rate is lower--5-25% (average--11%); conversion rate is lower - 0-27% (average--14%); postoperative mortality is lower 0-10% (average--3%); and average hospital stay is shorter--4-10 days (average--6 days). The difference is not significant but the results are better than in prospective studies. The risk factors were identical. Shock, delayed presentation (>24 hours), confounding medical condition, age >70 years, American Society of Anesthesiology III-IV degrees and Boey score--all above should be considered as preoperative laparoscopic repair risk factors. Inadequate ulcer localization, large perforation size (>6 mm diameter according to ones, >10 mm according to others) and ulcers with friable edges are also considered as laparoscopic repair risk factors: each of the factors independently is an indication for an open repair.
Effective heating of magnetic nanoparticle aggregates for in vivo nano-theranostic hyperthermia.
Wang, Chencai; Hsu, Chao-Hsiung; Li, Zhao; Hwang, Lian-Pin; Lin, Ying-Chih; Chou, Pi-Tai; Lin, Yung-Ya
2017-01-01
Magnetic resonance (MR) nano-theranostic hyperthermia uses magnetic nanoparticles to target and accumulate at the lesions and generate heat to kill lesion cells directly through hyperthermia or indirectly through thermal activation and control releasing of drugs. Preclinical and translational applications of MR nano-theranostic hyperthermia are currently limited by a few major theoretical difficulties and experimental challenges in in vivo conditions. For example, conventional models for estimating the heat generated and the optimal magnetic nanoparticle sizes for hyperthermia do not accurately reproduce reported in vivo experimental results. In this work, a revised cluster-based model was proposed to predict the specific loss power (SLP) by explicitly considering magnetic nanoparticle aggregation in in vivo conditions. By comparing with the reported experimental results of magnetite Fe 3 O 4 and cobalt ferrite CoFe 2 O 4 magnetic nanoparticles, it is shown that the revised cluster-based model provides a more accurate prediction of the experimental values than the conventional models that assume magnetic nanoparticles act as single units. It also provides a clear physical picture: the aggregation of magnetic nanoparticles increases the cluster magnetic anisotropy while reducing both the cluster domain magnetization and the average magnetic moment, which, in turn, shift the predicted SLP toward a smaller magnetic nanoparticle diameter with lower peak values. As a result, the heating efficiency and the SLP values are decreased. The improvement in the prediction accuracy in in vivo conditions is particularly pronounced when the magnetic nanoparticle diameter is in the range of ~10-20 nm. This happens to be an important size range for MR cancer nano-theranostics, as it exhibits the highest efficacy against both primary and metastatic tumors in vivo. Our studies show that a relatively 20%-25% smaller magnetic nanoparticle diameter should be chosen to reach the maximal heating efficiency in comparison with the optimal size predicted by previous models.
Effective heating of magnetic nanoparticle aggregates for in vivo nano-theranostic hyperthermia
Wang, Chencai; Hsu, Chao-Hsiung; Li, Zhao; Hwang, Lian-Pin; Lin, Ying-Chih; Chou, Pi-Tai; Lin, Yung-Ya
2017-01-01
Magnetic resonance (MR) nano-theranostic hyperthermia uses magnetic nanoparticles to target and accumulate at the lesions and generate heat to kill lesion cells directly through hyperthermia or indirectly through thermal activation and control releasing of drugs. Preclinical and translational applications of MR nano-theranostic hyperthermia are currently limited by a few major theoretical difficulties and experimental challenges in in vivo conditions. For example, conventional models for estimating the heat generated and the optimal magnetic nanoparticle sizes for hyperthermia do not accurately reproduce reported in vivo experimental results. In this work, a revised cluster-based model was proposed to predict the specific loss power (SLP) by explicitly considering magnetic nanoparticle aggregation in in vivo conditions. By comparing with the reported experimental results of magnetite Fe3O4 and cobalt ferrite CoFe2O4 magnetic nanoparticles, it is shown that the revised cluster-based model provides a more accurate prediction of the experimental values than the conventional models that assume magnetic nanoparticles act as single units. It also provides a clear physical picture: the aggregation of magnetic nanoparticles increases the cluster magnetic anisotropy while reducing both the cluster domain magnetization and the average magnetic moment, which, in turn, shift the predicted SLP toward a smaller magnetic nanoparticle diameter with lower peak values. As a result, the heating efficiency and the SLP values are decreased. The improvement in the prediction accuracy in in vivo conditions is particularly pronounced when the magnetic nanoparticle diameter is in the range of ~10–20 nm. This happens to be an important size range for MR cancer nano-theranostics, as it exhibits the highest efficacy against both primary and metastatic tumors in vivo. Our studies show that a relatively 20%–25% smaller magnetic nanoparticle diameter should be chosen to reach the maximal heating efficiency in comparison with the optimal size predicted by previous models. PMID:28894366
Sapudom, Jiranuwat; Rubner, Stefan; Martin, Steve; Kurth, Tony; Riedel, Stefanie; Mierke, Claudia T; Pompe, Tilo
2015-06-01
The behavior of cancer cells is strongly influenced by the properties of extracellular microenvironments, including topology, mechanics and composition. As topological and mechanical properties of the extracellular matrix are hard to access and control for in-depth studies of underlying mechanisms in vivo, defined biomimetic in vitro models are needed. Herein we show, how pore size and fibril diameter of collagen I networks distinctively regulate cancer cell morphology and invasion. Three-dimensional collagen I matrices with a tight control of pore size, fibril diameter and stiffness were reconstituted by adjustment of concentration and pH value during matrix reconstitution. At first, a detailed analysis of topology and mechanics of matrices using confocal laser scanning microscopy, image analysis tools and force spectroscopy indicate pore size and not fibril diameter as the major determinant of matrix elasticity. Secondly, by using two different breast cancer cell lines (MDA-MB-231 and MCF-7), we demonstrate collagen fibril diameter--and not pore size--to primarily regulate cell morphology, cluster formation and invasion. Invasiveness increased and clustering decreased with increasing fibril diameter for both, the highly invasive MDA-MB-231 cells with mesenchymal migratory phenotype and the MCF-7 cells with amoeboid migratory phenotype. As this behavior was independent of overall pore size, matrix elasticity is shown to be not the major determinant of the cell characteristics. Our work emphasizes the complex relationship between structural-mechanical properties of the extracellular matrix and invasive behavior of cancer cells. It suggests a correlation of migratory and invasive phenotype of cancer cells in dependence on topological and mechanical features of the length scale of single fibrils and not on coarse-grained network properties. Copyright © 2015 Elsevier Ltd. All rights reserved.
Synthesis of gold nanoparticles with graphene oxide.
Wang, Wenshuo; He, Dawei; Zhang, Xiqing; Duan, Jiahua; Wu, Hongpeng; Xu, Haiteng; Wang, Yongsheng
2014-05-01
Single sheets of functionalized graphene oxide are derived through chemical exfoliation of natural flake graphite. We present an effective synthetic method of graphene-gold nanoparticles hybrid nanocomposites. AFM (Atomic Force Microscope) was used to measure the thickness of the individual GO nanosheet. FTIR (Fourier transform infrared) spectroscopy was used to verify the attachment of oxygen functionalities on the surface of graphene oxide. TEM (Transmission Electron Microscope) data revealed the average diameters of the gold colloids and characterized the composite particles situation. Absorption spectroscopy showed that before and after synthesis the gold particle size did not change. Our studies indicate that the hybrid is potential substrates for catalysts and biosensors.
Preliminary structural design of a lunar transfer vehicle aerobrake. M.S. Thesis
NASA Technical Reports Server (NTRS)
Bush, Lance B.
1992-01-01
An aerobrake concept for a Lunar transfer vehicle was weight optimized through the use of the Taguchi design method, structural finite element analyses and structural sizing routines. Six design parameters were chosen to represent the aerobrake structural configuration. The design parameters included honeycomb core thickness, diameter to depth ratio, shape, material, number of concentric ring frames, and number of radial frames. Each parameter was assigned three levels. The minimum weight aerobrake configuration resulting from the study was approx. half the weight of the average of all twenty seven experimental configurations. The parameters having the most significant impact on the aerobrake structural weight were identified.
Cross-tail magnetic flux ropes as observed by the GEOTAIL spacecraft
NASA Technical Reports Server (NTRS)
Lepping, R. P.; Fairfield, D. H.; Jones, J.; Frank, L. A.; Paterson, W. R.; Kokubun, S.; Yamamoto, T.
1995-01-01
Ten transient magnetic structures in Earth's magnetotail, as observed in GEOTAIL measurements, selected for early 1993 (at (-) X(sub GSM) = 90 - 130 Earth radii), are shown to have helical magnetic field configurations similar to those of interplanetary magnetic clouds at 1 AU but smaller in size by a factor of approximately = 700. Such structures are shown to be well approximated by a comprehensive magnetic force-free flux-rope model. For this limited set of 10 events the rope axes are seen to be typically aligned with the Y(sub GSM) axis and the average diameter of these structures is approximately = 15 Earth radii.
Encapsulation of eugenol from clove oil using casein micelle for solid preparation
NASA Astrophysics Data System (ADS)
Wijayanto, Andri; Putri, Yeshinta Risky Priasmara; Hermansyah, Heri; Sahlan, Muhamad
2017-02-01
Liquid preparation of eugenol in clove oil form is one of eugenol preparation form that is easiest to get it nowadays in many level of purity. The problem is the liquid preparation of chemical is often not easy to handle than the solid one. In this study, we observe the effectivity of cow milk casein in case of encapsulating eugenol from clove oil for creating the solid preparation of eugenol in nanoscale size. The result is 63.86% eugenol from clove oil can be encapsulated by the casein. The average particle diameter is about 377.5 nm, with loading capacity until 67.2%.
Zhou, Wen; Wang, Guifen; Li, Cai; Xu, Zhantang; Cao, Wenxi; Shen, Fang
2017-10-20
Phytoplankton cell size is an important property that affects diverse ecological and biogeochemical processes, and analysis of the absorption and scattering spectra of phytoplankton can provide important information about phytoplankton size. In this study, an inversion method for extracting quantitative phytoplankton cell size data from these spectra was developed. This inversion method requires two inputs: chlorophyll a specific absorption and scattering spectra of phytoplankton. The average equivalent-volume spherical diameter (ESD v ) was calculated as the single size approximation for the log-normal particle size distribution (PSD) of the algal suspension. The performance of this method for retrieving cell size was assessed using the datasets from cultures of 12 phytoplankton species. The estimations of a(λ) and b(λ) for the phytoplankton population using ESD v had mean error values of 5.8%-6.9% and 7.0%-10.6%, respectively, compared to the a(λ) and b(λ) for the phytoplankton populations using the log-normal PSD. The estimated values of C i ESD v were in good agreement with the measurements, with r 2 =0.88 and relative root mean square error (NRMSE)=25.3%, and relatively good performances were also found for the retrieval of ESD v with r 2 =0.78 and NRMSE=23.9%.
Cytotoxicity and cellular uptake of different sized gold nanoparticles in ovarian cancer cells
NASA Astrophysics Data System (ADS)
Kumar, Dhiraj; Mutreja, Isha; Chitcholtan, Kenny; Sykes, Peter
2017-11-01
Nanomedicine has advanced the biomedical field with the availability of multifunctional nanoparticles (NPs) systems that can target a disease site enabling drug delivery and helping to monitor the disease. In this paper, we synthesised the gold nanoparticles (AuNPs) with an average size 18, 40, 60 and 80 nm, and studied the effect of nanoparticles size, concentration and incubation time on ovarian cancer cells namely, OVCAR5, OVCAR8, and SKOV3. The size measured by transmission electron microscopy images was slightly smaller than the hydrodynamic diameter; measured size by ImageJ as 14.55, 38.13, 56.88 and 78.56 nm. The cellular uptake was significantly controlled by the AuNPs size, concentration, and the cell type. The nanoparticles uptake increased with increasing concentration, and 18 and 80 nm AuNPs showed higher uptake ranging from 1.3 to 5.4 μg depending upon the concentration and cell type. The AuNPs were associated with a temporary reduction in metabolic activity, but metabolic activity remained more than 60% for all sample types; NPs significantly affected the cell proliferation activity in first 12 h. The increase in nanoparticle size and concentration induced the production of reactive oxygen species in 24 h.
Microencapsulation of 2-octylcyanoacrylate tissue adhesive for self-healing acrylic bone cement.
Brochu, Alice B W; Chyan, William J; Reichert, William M
2012-10-01
Here, we report the first phase of developing self-healing acrylic bone cement: the preparation and characterization of polyurethane (PUR) microcapsules containing a medical cyanoacrylate tissue adhesive. Capsules were prepared by interfacial polymerization of a toluene-2,4-diisocyanate-based polyurethane prepolymer with 1,4-butanediol to encapsulate 2-octylcyanoacrylate (OCA). Various capsule characteristics, including: resultant morphology, average size and size distribution, shell thickness, content and reactivity of encapsulated agent, and shelf life are investigated and their reliance on solvent type and amount, surfactant type and amount, temperature, pH, agitation rate, reaction time, and mode of addition of the oil phase to the aqueous phase are presented. Capsules had average diameters ranging from 74 to 222 μm and average shell thicknesses ranging from 1.5 to 6 μm. The capsule content was determined via thermogravimetric analysis and subsequent analysis of the capsules following up to 8 weeks storage revealed minimal loss of core contents. Mechanical testing of OCA-containing capsules showed individual capsules withstood compressive forces up to a few tenths of Newtons, and the contents released from crushed capsules generated tensile adhesive forces of a few Newtons. Capsules were successfully mixed into the poly(methyl methacrylate) bone cement, surviving the mixing process, exposure to methyl methacrylate monomer, and the resulting exothermic matrix curing. Copyright © 2012 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
J.S. Tumuluru; L.G. Tabil; Y. Song
2014-01-01
In the present study, specific energy for grinding and physical properties of wheat, canola, oat and barley straw grinds were investigated. The initial moisture content of the straw was about 0.13–0.15 (fraction total mass basis). Particle size reduction experiments were conducted in two stages: (1) a chopper without a screen, and (2) a hammer mill using three screen sizes (19.05, 25.4, and 31.75 mm). The lowest grinding energy (1.96 and 2.91 kWh t-1) was recorded for canola straw using a chopper and hammer mill with 19.05-mm screen size, whereas the highest (3.15 and 8.05 kWh t-1) was recorded for barleymore » and oat straws. The physical properties (geometric mean particle diameter, bulk, tapped and particle density, and porosity) of the chopped and hammer-milled wheat, barley, canola, and oat straw grinds measured were in the range of 0.98–4.22 mm, 36–80 kg m-3, 49–119 kg m-3, 600–1220 kg m-3, and 0.9–0.96, respectively. The average mean particle diameter was highest for the chopped wheat straw (4.22-mm) and lowest for the canola grind (0.98-mm). The canola grinds produced using the hammer mill (19.05-mm screen size) had the highest bulk and tapped density of about 80 and 119 kg m-3; whereas, the wheat and oat grinds had the lowest of about 58 and 88–90 kg m-3. The results indicate that the bulk and tapped densities are inversely proportional to the particle size of the grinds. The flow properties of the grinds calculated are better for chopped straws compared to hammer milled using smaller screen size (19.05 mm).« less
Number size distribution of particulate emissions of heavy-duty engines in real world test cycles
NASA Astrophysics Data System (ADS)
Lehmann, Urs; Mohr, Martin; Schweizer, Thomas; Rütter, Josef
Five in-service engines in heavy-duty trucks complying with Euro II emission standards were measured on a dynamic engine test bench at EMPA. The particulate matter (PM) emissions of these engines were investigated by number and mass measurements. The mass of the total PM was evaluated using the standard gravimetric measurement method, the total number concentration and the number size distribution were measured by a Condensation Particle Counter (lower particle size cut-off: 7 nm) and an Electrical Low Pressure Impactor (lower particle size: 32 nm), respectively. The transient test cycles used represent either driving behaviour on the road (real-world test cycles) or a type approval procedure. They are characterised by the cycle power, the average cycle power and by a parameter for the cycle dynamics. In addition, the particle number size distribution was determined at two steady-state operating modes of the engine using a Scanning Mobility Particle Sizer. For quality control, each measurement was repeated at least three times under controlled conditions. It was found that the number size distributions as well as the total number concentration of emitted particles could be measured with a good repeatability. Total number concentration was between 9×10 11 and 1×10 13 particles/s (3×10 13-7×10 14 p/kWh) and mass concentration was between 0.09 and 0.48 g/kWh. For all transient cycles, the number mean diameter of the distributions lay typically at about 120 nm for aerodynamic particle diameter and did not vary significantly. In general, the various particle measurement devices used reveal the same trends in particle emissions. We looked at the correlation between specific gravimetric mass emission (PM) and total particle number concentration. The correlation tends to be influenced more by the different engines than by the test cycles.
NASA Astrophysics Data System (ADS)
Paul, Bappi; Vadivel, Sethumathavan; Dhar, Siddhartha Sankar; Debbarma, Shyama; Kumaravel, M.
2017-05-01
In this paper, we report novel and green approach for one-pot biosynthesis of zinc oxide (ZnO) nanoparticles (NPs). Highly stable and hexagonal phase ZnO nanoparticles were synthesized using seeds extract from the tender pods of Parkia roxburghii and characterized by XRD, FT-IR, EDX, TEM, and N2 adsorption-desorption (BET) studies. The present method of synthesis of ZnO NPs is very efficient and cost effective. The powder XRD pattern furnished evidence for the formation of hexagonal close packing structure of ZnO NPs having average crystallite size 25.6 nm. The TEM image reveals rice shapes ZnO NPs are with an average diameter of 40-60 nm. The as-synthesized ZnO NPs has proved to be an excellent sonocatalysts for degradation of organic dye and synthesis of 2-benzimidazole derivatives.
NASA Technical Reports Server (NTRS)
Wiley, P. H.; Bostian, C. W.; Stutzman, W. L.
1973-01-01
The influence of polarization on millimeter wave propagation is investigated from both an experimental and a theoretical viewpoint. First, previous theoretical and experimental work relating to the attenuation and depolarization of millimeter waves by rainfall is discussed. Considerable detail is included in the literature review. Next, a theoretical model is developed to predict the cross polarization level during rainfall from the path average rain rate and the scattered field from a single raindrop. Finally, data from the VPI and SU depolarization experiment are presented as verification of the new model, and a comparison is made with other theories and experiments. Aspects of the new model are: (1) spherical rather than plane waves are assumed, (2) the average drop diameter is used rather than a drop size distribution, and (3) it is simple enough so that the effect which changing one or more parameters has on the crosspolarization level is easily seen.
Synthesis of ZnO Hexagonal Micro Discs on Glass Substrates Using the Spray Pyrolysis Technique
NASA Astrophysics Data System (ADS)
Ikhmayies, Shadia J.; Zbib, Mohamad B.
2017-07-01
Zinc oxide (ZnO) is an important transparent conducting oxide of potential use in solar cells, electronics, photoelectronics, and sensors. In this work ZnO micro discs were synthesized in thin film form on glass substrates using the low cost spray pyrolysis method. The films were prepared from a precursor solution of ZnCl2 in distilled water at a substrate temperature of 300 ± 5°C. The as-synthesized samples were analyzed with x-ray diffraction, scanning electron microscopy, and x-ray energy dispersive spectroscopy (EDS). The morphology of the films showed randomly distributed micro discs of hexagonal shape. The EDS reports showed that the films contained Cl and Fe. Size analysis was performed using ImageJ software, where the average diameter was found to be 4.8 ± 0.9 μm, and the average thickness was found to be 254 ± 43 nm.
Stella, Stefano; Italia, Leonardo; Geremia, Giulia; Rosa, Isabella; Ancona, Francesco; Marini, Claudia; Capogrosso, Cristina; Giglio, Manuela; Montorfano, Matteo; Latib, Azeem; Margonato, Alberto; Colombo, Antonio; Agricola, Eustachio
2018-02-06
A 3D transoesophageal echocardiography (3D-TOE) reconstruction tool has recently been introduced. The system automatically configures a geometric model of the aortic root and performs quantitative analysis of these structures. We compared the measurements of the aortic annulus (AA) obtained by semi-automated 3D-TOE quantitative software and manual analysis vs. multislice computed tomography (MSCT) ones. One hundred and seventy-five patients (mean age 81.3 ± 6.3 years, 77 men) who underwent both MSCT and 3D-TOE for annulus assessment before transcatheter aortic valve implantation were analysed. Hypothetical prosthetic valve sizing was evaluated using the 3D manual, semi-automated measurements using manufacturer-recommended CT-based sizing algorithm as gold standard. Good correlation between 3D-TOE methods vs. MSCT measurements was found, but the semi-automated analysis demonstrated slightly better correlations for AA major diameter (r = 0.89), perimeter (r = 0.89), and area (r = 0.85) (all P < 0.0001) than manual one. Both 3D methods underestimated the MSCT measurements, but semi-automated measurements showed narrower limits of agreement and lesser bias than manual measurements for most of AA parameters. On average, 3D-TOE semi-automated major diameter, area, and perimeter underestimated the respective MSCT measurements by 7.4%, 3.5%, and 4.4%, respectively, whereas minor diameter was overestimated by 0.3%. Moderate agreement for valve sizing for both 3D-TOE techniques was found: Kappa agreement 0.5 for both semi-automated and manual analysis. Interobserver and intraobserver agreements for the AA measurements were excellent for both techniques (intraclass correlation coefficients for all parameters >0.80). The 3D-TOE semi-automated analysis of AA is feasible and reliable and can be used in clinical practice as an alternative to MSCT for AA assessment. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2018. For permissions, please email: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sherif El-Eskandarany, M., E-mail: msherif@kisr.edu.kw; Al-Hazza, Abdulsalam
2014-11-15
We employed a high-energy ball mill for the synthesis of nanograined Ti{sub 55}C{sub 45} powders starting from elemental Ti and C powders. The mechanically induced self-propagating reaction that occurred between the reactant materials was monitored via a gas atmosphere gas-temperature-monitoring system. A single phase of NaCl-type TiC was obtained after 5 h of ball milling. To decrease the powder and grain sizes, the material was subjected to further ball milling time. The powders obtained after 200 h of milling possessed spherical-like morphology with average particle and grain sizes of 45 μm and 4.2 nm, respectively. The end-products obtained after 200more » h of ball milling time, were then consolidated into full dense compacts, using hot pressing and spark plasma sintering at 1500 and 34.5 MPa, with heating rates of 20 °C/min and 500 °C/min, respectively. Whereas hot pressing of the powders led to severe grain growth (∼ 436 nm in diameter), the as-spark plasma sintered powders maintained their nanograined characteristics (∼ 28 nm in diameter). The as-synthesized and as-consolidated powders were characterized, using X-ray diffraction, high-resolution electron microscopy, and scanning electron microscopy. The mechanical properties of the consolidated samples obtained via the hot pressing and spark plasma sintering techniques were characterized, using Vickers microhardness and non-destructive testing techniques. The Vickers hardness, Young's modulus, shear modulus and fracture toughness of as-spark plasma sintered samples were 32 GPa, 358 GPa, 151 GPa and 6.4 MPa·m{sup 1/2}, respectively. The effects of the consolidation approach on the grain size and mechanical properties were investigated and are discussed. - Highlights: • Room-temperature synthesizing of NaCl-type TiC • Dependence on the grain size on the ball milling time • Fabrication of equiaxed nanocrystalline grains with a diameter of 4.2 nm • Fabrication of nanocrystalline bulk TiC material by SPS with minimal grain growth • Dependence of improved mechanical properties on the consolidation techniques.« less
Stohlgren, Thomas J.
1992-01-01
The Big Stump Grove of giant sequoia (Sequoiadendron giganteum (Lindl.) Buchholz) was heavily logged between 1883 and 1889 and the stand naturally regenerated from seed following logging. In 1968, as part of a 100% sequoia tree inventory, all living sequoias (n = 3587) and dead trees and stumps (n=588) were measured (diameter at breast height, dbh) and mapped. A comparison of pre- to post-logging (85 years later in 1968) stand characteristics showed the estimated basal area of 56.7 m2 ha−1 in the pre-cut 1883 Big Stump Grove was very similar to the population mean basal area of 30 other giant sequoia groves (with more than 30 trees) in Sequoia and Kings Canyon National Parks. Sequoia density in 1968 was 1.5 times higher than the population mean, and over 45% of the basal area had been recovered after only 85 years. Assuming most re-establishment occurred over roughly a 9 year period (1883–1892), the diameter growth rate of trees less than 1.95 m dbh, averaged 6.1–6.8 mm year−1 but greatly varied as the 24 trees in the 1.8 m size class had a mean diameter growth rate of 21–24 mm year−1. Data generated by dividing the grove into 0.25 ha contiguous plots indicated that only about 3.3 ha of the pre-cut 1883 grove did not have sequoia regeneration whereas 16.5 ha of the 1968 grove had sequoia regeneration but no sign of logs or stumps. The proportion of only-regeneration plots was significantly greater (Pt=0; 1968) stand, overrepresentation of 0.3–1.2 m dbh trees may produce a bimodal size distribution lasting perhaps 800 years or more into the future. Giant sequoia stand characteristics such as age and size structure are not highly resilient and may take several centuries to approach the ‘domain’ of age or size structure typical of old-growth sequoia forests. Grove boundaries may be less stable following a major disturbance.
Tai, Anna Y-C; Chen, L-W Antony; Wang, Xiaoliang; Chow, Judith C; Watson, John G
2017-02-01
Lake Tahoe, a North American alpine lake long appreciated for its clear water and geographic setting, has experienced a trend of declining water clarity due to increasing nutrient and particle inputs. Contributions from atmospheric deposition of particulate matter (PM) could be important, yet they are inadequately quantified. This study established a yearlong deposition monitoring network in the northern Lake Tahoe Basin. Dry deposition was quantified on surrogate surfaces while wet deposition was based on particles suspended in precipitation at 24-hour resolution. The particle size ranges by these passive techniques were 1-64μm and 0.5-20μm in diameter for dry and wet deposition, respectively. Dry deposition of submicrometer (0.5-1μm) particles was also estimated by extrapolation of a lognormal size distribution. Higher daily number deposition fluxes (NDF dry and NDF wet ) were found at a near-shore site, confirming substantial impacts of commercial and tourist activities. The two more isolated sites indicated a uniform regional background. On average, daily NDF dry is about one order of magnitude lower than daily NDF wet . Dry deposition velocities increased rapidly with particle size, as evidenced by collocated measurements of NDF dry and ambient particle number concentrations, though it seems less so for wet deposition due to different scavenging mechanisms. Despite fewer "wet" days than "dry" days during the monitoring period, wet processes dominated seasonal particle deposition, particularly in winter and spring when most precipitation occurred. Adopting sediment (insoluble, inorganic) particle fraction estimates from the literature, this study reports an annual particle flux of 2.9-5.2×10 10 #m -2 yr -1 for sediment particles with 1-20μm diameter and 6.1-11×10 10 #m -2 yr -1 for those with 0.5-20μm diameter. Implications of these findings to the current knowledge of atmospheric deposition in the Lake Tahoe Total Maximum Daily Load (TMDL) are discussed. Copyright © 2016 Elsevier B.V. All rights reserved.
Permeability model of sintered porous media: analysis and experiments
NASA Astrophysics Data System (ADS)
Flórez Mera, Juan Pablo; Chiamulera, Maria E.; Mantelli, Marcia B. H.
2017-11-01
In this paper, the permeability of porous media fabricated from copper powder sintering process was modeled and measured, aiming the use of the porosity as input parameter for the prediction of the permeability of sintering porous media. An expression relating the powder particle mean diameter with the permeability was obtained, based on an elementary porous media cell, which is physically represented by a duct formed by the arrangement of spherical particles forming a simple or orthorhombic packing. A circular duct with variable section was used to model the fluid flow within the porous media, where the concept of the hydraulic diameter was applied. Thus, the porous is modeled as a converging-diverging duct. The electrical circuit analogy was employed to determine two hydraulic resistances of the cell: based on the Navier-Stokes equation and on the Darcýs law. The hydraulic resistances are compared between themselves and an expression to determine the permeability as function of average particle diameter is obtained. The atomized copper powder was sifted to reduce the size dispersion of the particles. The porosities and permeabilities of sintered media fabricated from powders with particle mean diameters ranging from 20 to 200 microns were measured, by means of the image analysis method and using an experimental apparatus. The permeability data of a porous media, made of copper powder and saturated with distilled water, was used to compare with the permeability model. Permeability literature models, which considers that powder particles have the same diameter and include porosity data as input parameter, were compared with the present model and experimental data. This comparison showed to be quite good.
Feasibility of recanalization of human coronary arteries using high-intensity ultrasound.
Ernst, A; Schenk, E A; Woodlock, T J; Alliger, H; Gottlieb, S; Child, S Z; Meltzer, R S
1994-01-15
To investigate the feasibility of ultrasonic recanalization of obstructed human coronary arteries in vitro, high-intensity ultrasound was applied to 16 coronary arteries obtained at autopsy, using a prototype instrument enabling insonification through a catheter tip. It was a 119 cm long, 0.95 mm thick wire in an 8Fr catheter connected to an external ultrasonic transformer and power generator. A 5 MHz phased-array 2-dimensional echocardiography instrument was used to determine minimal luminal diameter and percent diameter narrowing before and after ultrasound application. The ultrasonic energy was delivered at 21.5 kHz and with a 52 +/- 19 micrometer average amplitude of tip displacement. The mean percent luminal diameter narrowing, flow rate and mean pressure gradient before ultrasound exposure were 74 +/- 11%, 97 +/- 61 ml/min, and 92 +/- 18 mm Hg, respectively. After recanalization, the mean percent luminal diameter narrowing decreased to 45 +/- 17% (p < 0.001), the mean flow rate increased to 84 +/- 92 ml/min (p < 0.001), and the mean pressure gradient was reduced to 45 +/- 24 mm Hg (p < 0.001). Of the debris particles, 95% had a diameter < 9 microns (range 5 to 12). Arterial perforation occurred in 5 of 16 arteries (31%) and all 5 occurred due to stiff wire manipulation and without ultrasound application. Mechanical fracture of the wire occurred in 8 cases (50%). No signs of thermal injury were found on histology. Thus, ultrasonic recanalization of human coronary arteries in vitro is feasible. It may reduce obstruction and improve blood flow. Debris sizes are sufficiently small to minimize the hazard of peripheral embolization.
Variations in the size of focal nodular hyperplasia on magnetic resonance imaging.
Ramírez-Fuentes, C; Martí-Bonmatí, L; Torregrosa, A; Del Val, A; Martínez, C
2013-01-01
To evaluate the changes in the size of focal nodular hyperplasia (FNH) during long-term magnetic resonance imaging (MRI) follow-up. We reviewed 44 FNHs in 30 patients studied with MRI with at least two MRI studies at least 12 months apart. We measured the largest diameter of the lesion (inmm) in contrast-enhanced axial images and calculated the percentage of variation as the difference between the maximum diameter in the follow-up and the maximum diameter in the initial study. We defined significant variation in size as variation greater than 20%. We also analyzed predisposing hormonal factors. The mean interval between the two imaging studies was 35±2 months (range: 12-94). Most lesions (80%) remained stable during follow-up. Only 9 of the 44 lesions (20%) showed a significant variation in diameter: 7 (16%) decreased in size and 2 (4%) increased, with variations that reached the double of the initial size. The change in size was not related to pregnancy, menopause, or the use of birth control pills or corticoids. Changes in the size of FNHs during follow-up are relatively common and should not lead to a change in the diagnosis. These variations in size seem to be independent of hormonal factors that are considered to predispose. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.
NASA Astrophysics Data System (ADS)
Brisse, H. J.; Brenot, J.; Pierrat, N.; Gaboriaud, G.; Savignoni, A.; DeRycke, Y.; Neuenschwander, S.; Aubert, B.; Rosenwald, J.-C.
2009-04-01
This study assessed and compared various image quality indices in order to manage the dose of pediatric abdominal MDCT protocols and to provide guidance on dose reduction. PMMA phantoms representing average body diameters at birth, 1 year, 5 years, 10 years and 15 years of age were scanned in a four-channel MDCT with a standard pediatric abdominal CT protocol. Image noise (SD, standard deviation of CT number), noise derivative (ND, derivative of the function of noise with respect to dose) and contrast-to-noise ratio (CNR) were measured. The 'relative' low-contrast detectability (rLCD) was introduced as a new quantity to adjust LCD to the various phantom diameters on the basis of the LCD1% assessed in a Catphan® phantom and a constant central absorbed dose. The required variations of CTDIvol16 with respect to phantom size were analyzed in order to maintain each image quality index constant. The use of a fixed SD or CNR level leads to major dose ratios between extreme patient sizes (factor 22.7 to 44 for SD, 31.7 to 51.5 for CNR2.8%), whereas fixed ND and rLCD result in acceptable dose ratios ranging between factors of 2.9 and 3.9 between extreme phantom diameters. For a 5-9 mm rLCD1%, adjusted ND values range between -0.84 and -0.11 HU mGy-1. Our data provide guidance on dose reduction on the basis of patient dimensions and the required rLCD (e.g., to get a constant 7 mm rLCD1% for abdominal diameters of 10, 13, 16, 20 and 25 cm, tube current-time product should be adjusted in order to obtain CTDIvol16 values of 6.2, 7.2, 8.8, 11.6 and 17.7 mGy, respectively).
Cheng, S L; Wong, S L; Lu, S W; Chen, H
2008-09-01
We report here the successful fabrication of large-area size-tunable periodic arrays of cobalt and Co-silicide nanodots on silicon substrates by employing the colloidal nanosphere lithography (NSL) technique and heat treatments. The growth of low-resistivity epitaxial CoSi(2) was found to be more favorable for the samples with smaller Co nanodot sizes. The sizes of the epitaxial CoSi(2) nanodots can be tuned from 50 to 100 nm by varying the diameter of the colloidal spheres and annealing temperatures. The epitaxial CoSi(2) nanodots were found to grow with an epitaxial orientation with respect to the (001)Si substrates: [001]CoSi(2)//[001]Si and (200)CoSi(2)//(400)Si. From the results of planview HRTEM, XTEM, and SAED analysis, the epitaxial CoSi(2) nanodots were identified to be inverse pyramids in shape, and the average sizes of the faceted silicide nanodots were measured to decrease with annealing temperature. The observed results present the exciting prospect that with appropriate controls, the colloidal NSL technique promises to facilitate the growth of a variety of well-ordered silicide nanodots with selected shape, size, and periodicity.
C-Sphere Strength-Size Scaling in a Bearing-Grade Silicon Nitride
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wereszczak, Andrew A; Jadaan, Osama M.; Kirkland, Timothy Philip
2008-01-01
A C-sphere specimen geometry was used to determine the failure strength distributions of a commercially available bearing-grade silicon nitride (Si3N4) having ball diameters of 12.7 and 25.4 mm. Strengths for both diameters were determined using the combination of failure load, C sphere geometry, and finite element analysis and fitted using two-parameter Weibull distributions. Effective areas of both diameters were estimated as a function of Weibull modulus and used to explore whether the strength distributions predictably strength-scaled between each size. They did not. That statistical observation suggested that the same flaw type did not limit the strength of both ball diametersmore » indicating a lack of material homogeneity between the two sizes. Optical fractography confirmed that. It showed there were two distinct strength-limiting flaw types in both ball diameters, that one flaw type was always associated with lower strength specimens, and that significantly higher fraction of the 24.5-mm-diameter c-sphere specimens failed from it. Predictable strength-size-scaling would therefore not result as a consequence of this because these flaw types were not homogenously distributed and sampled in both c-sphere geometries.« less
Height-diameter equations for thirteen midwestern bottomland hardwood species
Kenneth C. Colbert; David R. Larsen; James R. Lootens
2002-01-01
Height-diameter equations are often used to predict the mean total tree height for trees when only diameter at breast height (dbh) is measured. Measuring dbh is much easier and is subject to less measurement error than total tree height. However, predicted heights only reflect the average height for trees of a particular diameter. In this study, we present a set of...
Experimental strategies for imaging bioparticles with femtosecond hard X-ray pulses
Okamoto, Kenta; Bielecki, Johan; Maia, Filipe R. N. C.; Mühlig, Kerstin; Seibert, M. Marvin; Hantke, Max F.; Benner, W. Henry; Svenda, Martin; Ekeberg, Tomas; Loh, N. Duane; Pietrini, Alberto; Zani, Alessandro; Rath, Asawari D.; Westphal, Daniel; Kirian, Richard A.; Awel, Salah; Wiedorn, Max O.; van der Schot, Gijs; Carlsson, Gunilla H.; Hasse, Dirk; Sellberg, Jonas A.; Barty, Anton; Andreasson, Jakob; Boutet, Sébastien; Williams, Garth; Koglin, Jason; Hajdu, Janos; Larsson, Daniel S. D.
2017-01-01
This study explores the capabilities of the Coherent X-ray Imaging Instrument at the Linac Coherent Light Source to image small biological samples. The weak signal from small samples puts a significant demand on the experiment. Aerosolized Omono River virus particles of ∼40 nm in diameter were injected into the submicrometre X-ray focus at a reduced pressure. Diffraction patterns were recorded on two area detectors. The statistical nature of the measurements from many individual particles provided information about the intensity profile of the X-ray beam, phase variations in the wavefront and the size distribution of the injected particles. The results point to a wider than expected size distribution (from ∼35 to ∼300 nm in diameter). This is likely to be owing to nonvolatile contaminants from larger droplets during aerosolization and droplet evaporation. The results suggest that the concentration of nonvolatile contaminants and the ratio between the volumes of the initial droplet and the sample particles is critical in such studies. The maximum beam intensity in the focus was found to be 1.9 × 1012 photons per µm2 per pulse. The full-width of the focus at half-maximum was estimated to be 500 nm (assuming 20% beamline transmission), and this width is larger than expected. Under these conditions, the diffraction signal from a sample-sized particle remained above the average background to a resolution of 4.25 nm. The results suggest that reducing the size of the initial droplets during aerosolization is necessary to bring small particles into the scope of detailed structural studies with X-ray lasers. PMID:28512572
Schneider, Craig S.; Xu, Qingguo; Boylan, Nicholas J.; Chisholm, Jane; Tang, Benjamin C.; Schuster, Benjamin S.; Henning, Andreas; Ensign, Laura M.; Lee, Ethan; Adstamongkonkul, Pichet; Simons, Brian W.; Wang, Sho-Yu S.; Gong, Xiaoqun; Yu, Tao; Boyle, Michael P.; Suk, Jung Soo; Hanes, Justin
2017-01-01
Mucoadhesive particles (MAP) have been widely explored for pulmonary drug delivery because of their perceived benefits in improving particle residence in the lungs. However, retention of particles adhesively trapped in airway mucus may be limited by physiologic mucus clearance mechanisms. In contrast, particles that avoid mucoadhesion and have diameters smaller than mucus mesh spacings rapidly penetrate mucus layers [mucus-penetrating particles (MPP)], which we hypothesized would provide prolonged lung retention compared to MAP. We compared in vivo behaviors of variously sized, polystyrene-based MAP and MPP in the lungs following inhalation. MAP, regardless of particle size, were aggregated and poorly distributed throughout the airways, leading to rapid clearance from the lungs. Conversely, MPP as large as 300 nm exhibited uniform distribution and markedly enhanced retention compared to size-matched MAP. On the basis of these findings, we formulated biodegradable MPP (b-MPP) with an average diameter of <300 nm and examined their behavior following inhalation relative to similarly sized biodegradable MAP (b-MAP). Although b-MPP diffused rapidly through human airway mucus ex vivo, b-MAP did not. Rapid b-MPP movements in mucus ex vivo correlated to a more uniform distribution within the airways and enhanced lung retention time as compared to b-MAP. Furthermore, inhalation of b-MPP loaded with dexamethasone sodium phosphate (DP) significantly reduced inflammation in a mouse model of acute lung inflammation compared to both carrier-free DP and DP-loaded MAP. These studies provide a careful head-to-head comparison of MAP versus MPP following inhalation and challenge a long-standing dogma that favored the use of MAP for pulmonary drug delivery. PMID:28435870
Gulzari, Usman Ali; Sajid, Muhammad; Anjum, Sheraz; Agha, Shahrukh; Torres, Frank Sill
2016-01-01
A Mesh topology is one of the most promising architecture due to its regular and simple structure for on-chip communication. Performance of mesh topology degraded greatly by increasing the network size due to small bisection width and large network diameter. In order to overcome this limitation, many researchers presented modified Mesh design by adding some extra links to improve its performance in terms of network latency and power consumption. The Cross-By-Pass-Mesh was presented by us as an improved version of Mesh topology by intelligent addition of extra links. This paper presents an efficient topology named Cross-By-Pass-Torus for further increase in the performance of the Cross-By-Pass-Mesh topology. The proposed design merges the best features of the Cross-By-Pass-Mesh and Torus, to reduce the network diameter, minimize the average number of hops between nodes, increase the bisection width and to enhance the overall performance of the network. In this paper, the architectural design of the topology is presented and analyzed against similar kind of 2D topologies in terms of average latency, throughput and power consumption. In order to certify the actual behavior of proposed topology, the synthetic traffic trace and five different real embedded application workloads are applied to the proposed as well as other competitor network topologies. The simulation results indicate that Cross-By-Pass-Torus is an efficient candidate among its predecessor's and competitor topologies due to its less average latency and increased throughput at a slight cost in network power and energy for on-chip communication.
Fluvial sediment of the Mississippi River at St. Louis, Missouri
Jordan, Paul Robert
1965-01-01
An investigation of the fluvial sediment of the Mississippi River at St. Louis, Mo., was begun in 1948. Most data have been obtained only to determine the daily suspended-sediment discharge and the particle-size distribution of suspended sediment and bed material, but a few data have been obtained to study the flow resistance, the vertical distribution of sediment and velocity, and the bed-material discharge. The flow of the Mississippi River at St. Louis is made up of the flows from the Missouri River, which had an average flow of 79,860 cubic feet per second for 1897-1958 at Hermann, Mo., and from the upper Mississippi River, which had an average flow of 91,890 cubic feet per second for 1928-58 at Alton, Il. The Missouri River is partly controlled by reservoirs that had a total capacity of 90,300,000 acre-feet in 1956, and the upper Mississippi River is partly controlled by lakes and reservoirs that had a total capacity of 4,890,000 acre-feet in 1956. The flows of the Missouri and upper Mississippi Rivers have not become mixed at St. Louis; so the river has a lateral gradient of suspended-sediment concentration. The concentration near the west bank has been as much as 2,400 parts per million greater than the concentration near the east bank. Suspended-sediment discharges from April 1948 to September 1958 ranged from 4,250 to 7,010,000 tons per day and averaged 496,000 tons per day. Mean concentrations for water years decreased steadily from 1,690 parts per million in 1949 to 403 parts per million in 1956, but they increased to 756 parts per million in 1958. Effects of new reservoirs in the Missouri River basin on the concentration have been obscured by the close relation of concentration to streamflow. Measured suspended-sediment discharge through September 1958 averaged 47 percent clay, 38 percent silt, and 15 percent sand. Variations of particle size were due mainly to differences in the source areas of the sediment. Most of the bed material in the main flow was between 0.125 and 1.000 millimeter in diameter. The average of median diameters was related to the discharge for periods of 1 year and longer. Geometric quartile deviations of the bed material ranged from 1.1 to 2.5 and averaged 1.5. The mean elevation of the bed had a range of almost 10 feet and was related to the median diameter of bed material by the regression equation hb=363.0 - 7.8 d50 for which the standard error of estimate was 0.91 foot. The resistance to flow as measured by Manning's n ranged from 0.024 to 0.041 and was related to the discharge and mean velocity but not to the shear velocity. Normal dune height is 2-8 feet, and average dune length is about 250 feet. When the resistance to flow was low, much of the bed was fairly fiat; a few dunes were present, but they were much longer than the average. For a given discharge during individual rises in stage, the gage height was lower for increasing discharge than for decreasing discharge even though the bed elevation was higher. The changes in gage height were not caused by changes in energy gradient due to changing discharge, by channel storage between the gage and the measuring section, nor by return of overbank flow; but they were probably caused by a combination of changes in roughness due to changing bed configuration and of changes in turbulence constant due to changing sediment concentration. Turbulence constants (Von Karman's k) computed from velocity measurements at 5-10 points in the vertical and from routine velocity measurements at 2 points in the vertical averaged 0.35 and 0.33, respectively. The exponent z1 of the vertical distribution of concentration for different size ranges varied with about the 0.77 power of the fall velocity. Except for the difference between the theoretical variation and the actual variation of z1 with changing fall velocity, the theoretical equation for the vertical distribution of sediment concentration seems to apply reasonably well for the Miss
[Study on accuracy of endoscopic polyp size measurement by disposable graduated biopsy forceps].
Liu, Ping; Zhang, Xiu; Lin, Hui-ping; Jin, Hei-jing; Leng, Qiang; Zhang, Jin-hao; Zhang, Yang; Yao, Hang; Wu, Kun-lan
2013-12-01
To study the accuracy of endoscopic polyp size measurement by disposable graduated biopsy forceps (DGBF). Accurate gradation of 1 mm was made in the wire of disposable graduated biopsy forceps, which was used to measure the size of tumors under endoscopy. Fifty-eight polyps from 43 patients underwent endoscopy in our department from May to June 2013 were enrolled. Size of polyp was measured and compared among DGBF, routine estimation and direct measurement after resection. The accuracy of polyp size measurement was investigated by four colonoscopists who had finished at least 2000 procedures of colonoscopy. The mean diameter of post-polypectomy measurement was (1.02±0.84) cm. Diameter was less than 1 cm in 36 polyps, 1 to 2 cm in 15, and over 2 cm in 7. The mean diameter of visual estimation was (1.29±1.07) cm, and the difference was significant as compared with actual size (P=0.000). The mean diameter measured by DGBF was (1.02±0.82) cm, and the difference was not significant as compared with actual size (P=0.775). The ratio of visual estimation to actual size was 1.29±0.31, and DGBF estimation to actual size was 1.02±0.11 with significant difference (P=0.000). The accurate rate of DGBF in estimating polyp size was 77.6% (45/58), which was obviously higher as compared to visual estimation [19.0% (11/58), P=0.000]. The accuracy of DGBF as a scale in the estimation of poly size increases as compared to visual estimation.
Clustering, randomness, and regularity in cloud fields: 2. Cumulus cloud fields
NASA Astrophysics Data System (ADS)
Zhu, T.; Lee, J.; Weger, R. C.; Welch, R. M.
1992-12-01
During the last decade a major controversy has been brewing concerning the proper characterization of cumulus convection. The prevailing view has been that cumulus clouds form in clusters, in which cloud spacing is closer than that found for the overall cloud field and which maintains its identity over many cloud lifetimes. This "mutual protection hypothesis" of Randall and Huffman (1980) has been challenged by the "inhibition hypothesis" of Ramirez et al. (1990) which strongly suggests that the spatial distribution of cumuli must tend toward a regular distribution. A dilemma has resulted because observations have been reported to support both hypotheses. The present work reports a detailed analysis of cumulus cloud field spatial distributions based upon Landsat, Advanced Very High Resolution Radiometer, and Skylab data. Both nearest-neighbor and point-to-cloud cumulative distribution function statistics are investigated. The results show unequivocally that when both large and small clouds are included in the cloud field distribution, the cloud field always has a strong clustering signal. The strength of clustering is largest at cloud diameters of about 200-300 m, diminishing with increasing cloud diameter. In many cases, clusters of small clouds are found which are not closely associated with large clouds. As the small clouds are eliminated from consideration, the cloud field typically tends towards regularity. Thus it would appear that the "inhibition hypothesis" of Ramirez and Bras (1990) has been verified for the large clouds. However, these results are based upon the analysis of point processes. A more exact analysis also is made which takes into account the cloud size distributions. Since distinct clouds are by definition nonoverlapping, cloud size effects place a restriction upon the possible locations of clouds in the cloud field. The net effect of this analysis is that the large clouds appear to be randomly distributed, with only weak tendencies towards regularity. For clouds less than 1 km in diameter, the average nearest-neighbor distance is equal to 3-7 cloud diameters. For larger clouds, the ratio of cloud nearest-neighbor distance to cloud diameter increases sharply with increasing cloud diameter. This demonstrates that large clouds inhibit the growth of other large clouds in their vicinity. Nevertheless, this leads to random distributions of large clouds, not regularity.
Photodegradation of Eosin Y Using Silver-Doped Magnetic Nanoparticles
Alzahrani, Eman
2015-01-01
The purification of industrial wastewater from dyes is becoming increasingly important since they are toxic or carcinogenic to human beings. Nanomaterials have been receiving significant attention due to their unique physical and chemical properties compared with their larger-size counterparts. The aim of the present investigation was to fabricate magnetic nanoparticles (MNPs) using a coprecipitation method, followed by coating with silver (Ag) in order to enhance the photocatalytic activity of the MNPs by loading metal onto them. The fabricated magnetic nanoparticles coated with Ag were characterised using different instruments such as a scanning electron microscope (SEM), transmission electron microscopy (TEM), energy-dispersive X-ray (EDAX) spectroscopy, and X-ray diffraction (XRD) analysis. The average size of the magnetic nanoparticles had a mean diameter of about 48 nm, and the average particle size changed to 55 nm after doping. The fabricated Ag-doped magnetic nanoparticles were used for the degradation of eosin Y under UV-lamp irradiation. The experimental results revealed that the use of fabricated magnetic nanoparticles coated with Ag can be considered as reliable methods for the removal of eosin Y since the slope of evaluation of pseudo-first-order rate constant from the slope of the plot between ln(C o/C) and the irradiation time was found to be linear. Ag-Fe3O4 nanoparticles would be considered an efficient photocatalyst to degrade textile dyes avoiding the tedious filtration step. PMID:26617638
Baskaran, Balraj; Muthukumarasamy, Arulmozhi; Chidambaram, Siva; Sugumaran, Abimanyu; Ramachandran, Krithikadevi; Rasu Manimuthu, Thaneswari
2017-04-01
Biosynthesis of novel therapeutic nano-scale materials for biomedical and pharmaceutical applications has been enormously developed, since last decade. Herein, the authors report an ecological way of synthesising the platinum nanoparticles (PtNPs) using Streptomyces sp. for the first time . The produced PtNPs exhibited the face centred cubic system. The fourier transform infrared spectrum revealed the existence of amino acids in proteins which serves as an essential reductant for the formation of PtNPs. The spherical morphology of the PtNPs with an average size of 20-50 nm was observed from topographical images of atomic force microscopy and field emission scanning electron microscopy. The X-ray fluorescence spectrum confirms the presence of PtNPs with higher purity. The PtNPs size was further confirmed with transmission electron microscopy analysis and the particles were found to exist in the same size regime. Additionally, PtNPs showed the characteristic surface plasmon resonance peak at 262 nm. Dynamic light scattering studies report that 97.2% of particles were <100 nm, with an average particle diameter of about 45 nm. Furthermore, 3-(4, 5-dimethyl-2-thiazolyl)-2, 5-diphenyl-tetrazolium assay based in vitro cytotoxicity analysis was conducted for the PtNPs, which showed the inhibitory concentration (IC 50 ) at 31.2 µg/ml against Michigan Cancer Foundation-7 breast cancer cells.
Two-stage, low noise advanced technology fan. 5: Acoustic final report
NASA Technical Reports Server (NTRS)
Sofrin, T. G.; Riloff, N., Jr.
1975-01-01
The NASA Q2S(quiet two-stage) fan is a 0.836m (32.9 in.) diameter model of the STF 433 engine fan, selected in a 1972 study for an Advanced Technology Transport (ATT) airplane. Noise-control features include: low tip speed, moderate stage pressure rise, large blade-vane spacings, no inlet guide vanes, and optimum blade and vane numbers. Tests were run on the baseline Q2S fan with standard inlet and discharge ducts. Further tests were made of a translating centerbody sonic inlet device and treated discharge ducts. Results were scaled to JT8D and JT3D engine fan size for comparison with current two-stage fans, and were also scaled to STF 433 fan size to compare calculated ATT flyover noise with FAR 36 limits. Baseline Q2S results scaled to JT8D and JT3D engine fan sizes showed substantial noise reductions. Calculated unsuppressed baseline ATT flyovers averaged about 2.5 EPNdB below FAR 36 limits. Using measured sonic inlet results, scaled baseline Q2S fan results, and calculated attenuations for a 1975 technology duct liner, projected flyover noise calculations for the ATT averaged about FAR 36 limits minus 10 EPNdB. Advances in suppression technology required to meet the 1985 goal of FAR 36 limits minus 20 EPNdB are discussed.
Synthesis of wrinkled mesoporous silica and its reinforcing effect for dental resin composites.
Wang, Ruili; Habib, Eric; Zhu, X X
2017-10-01
The aim of this work is to explore the reinforcing effect of wrinkled mesoporous silica (WMS), which should allow micromechanical resin matrix/filler interlocking in dental resin composites, and to investigate the effect of silica morphology, loading, and compositions on their mechanical properties. WMS (average diameter of 496nm) was prepared through the self-assembly method and characterized by the use of the electron microscopy, dynamic light scattering, and the N 2 adsorption-desorption measurements. The mechanical properties of resin composites containing silanized WMS and nonporous smaller silica were evaluated with a universal mechanical testing machine. Field-emission scanning electron microscopy was used to study the fracture morphology of dental composites. Resin composites including silanized silica particles (average diameter of 507nm) served as the control group. Higher filler loading of silanized WMS substantially improved the mechanical properties of the neat resin matrix, over the composites loaded with regular silanized silica particles similar in size. The impregnation of smaller secondary silica particles with diameters of 90 and 190nm, denoted respectively as Si90 and Si190, increased the filler loading of the bimodal WMS filler (WMS-Si90 or WMS-Si190) to 60wt%, and the corresponding composites exhibited better mechanical properties than the control fillers made with regular silica particles. Among all composites, the optimal WMS-Si190- filled composite (mass ratio WMS:Si190=10:90, total filler loading 60wt%) exhibited the best mechanical performance including flexural strength, flexural modulus, compressive strength and Vickers microhardness. The incorporation of WMS and its mixed bimodal fillers with smaller silica particles led to the design and formulation of dental resin composites with superior mechanical properties. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Effect of impinging plate geometry on the self-excitation of subsonic impinging jets
NASA Astrophysics Data System (ADS)
Vinoth, B. R.; Rathakrishnan, E.
2011-11-01
In the generation of discrete tones by subsonic impinging jets, there exists a difference of opinion as how the feedback is achieved, i.e., the path of the feedback acoustic waves is whether inside the jet or outside the jet? The only available model (Tam and Ahuja model) for the prediction of an average subsonic jet impingement tone frequency assumes that the upstream part of the feedback loop is closed by an upstream propagating neutral wave of the jet. But, there is no information about the plate geometry in the model. The present study aims at understanding the effect of the plate geometry (size and co-axial hole in the plate) on the self-excitation process of subsonic impinging jets and the path of the acoustic feedback to the nozzle exit. The present results show that there is no effect of plate diameter on the frequency of the self-excitation. A new type of tones is generated for plates with co-axial hole (hole diameter is equal to nozzle exit diameter) for Mach numbers 0.9 and 0.95, in addition to the axisymmetric and helical mode tones observed for plates without co-axial hole. The stability results show that the Strouhal number of the least dispersive upstream propagating neutral waves match with the average Strouhal number of the new tones observed in the present experiments. The present study extends the validity of the model of Tam and Ahuja to a plate with co-axial hole (annular plate) and by doing so, we indirectly confirmed that the major acoustic feedback path to the nozzle exit is inside the jet.
Jin, Hei-Ying; Leng, Qiang
2015-01-01
AIM: To determine the accuracy of endoscopic polyp size measurements using disposable graduated biopsy forceps (DGBF). METHODS: Gradations accurate to 1 mm were assessed with the wire of disposable graduated biopsy forceps. When a polyp was noted, endoscopists determined the width of the polyp; then, the graduated biopsy forceps was inserted and the largest diameter of the tumor was measured. After excision, during surgery or endoscopy, the polyp was measured using the vernier caliper. RESULTS: One hundred and thirty-three colorectal polyps from 119 patients were studied. The mean diameter, by post-polypectomy measurement, was 0.92 ± 0.69 cm; 83 were < 1 cm, 36 were between 1 and 2 cm, and 14 were > 2 cm. The mean diameter, by visual estimation, was 1.15 ± 0.88 cm; compared to the actual size measured using vernier calipers, the difference was statistically significant. The mean diameter measured using the DGBF was 0.93 ± 0.68 cm; compared to the actual size measured using vernier calipers, this difference was not statistically significant. The ratio between the mean size estimated by visual estimation and the actual size was significantly different from that between the mean size estimated using the DGBF and the actual size (1.26 ± 0.30 vs 1.02 ± 0.11). CONCLUSION: The accuracy of polyp size estimation was low by visual assessment; however, it improved when the DGBF was used. PMID:25605986