Sample records for average glandular dose

  1. MO-F-CAMPUS-I-02: Accuracy in Converting the Average Breast Dose Into the Mean Glandular Dose (MGD) Using the F-Factor in Cone Beam Breast CT- a Monte Carlo Study Using Homogeneous and Quasi-Homogeneous Phantoms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lai, C; Zhong, Y; Wang, T

    2015-06-15

    Purpose: To investigate the accuracy in estimating the mean glandular dose (MGD) for homogeneous breast phantoms by converting from the average breast dose using the F-factor in cone beam breast CT. Methods: EGSnrc-based Monte Carlo codes were used to estimate the MGDs. 13-cm in diameter, 10-cm high hemi-ellipsoids were used to simulate pendant-geometry breasts. Two different types of hemi-ellipsoidal models were employed: voxels in quasi-homogeneous phantoms were designed as either adipose or glandular tissue while voxels in homogeneous phantoms were designed as the mixture of adipose and glandular tissues. Breast compositions of 25% and 50% volume glandular fractions (VGFs), definedmore » as the ratio of glandular tissue voxels to entire breast voxels in the quasi-homogeneous phantoms, were studied. These VGFs were converted into glandular fractions by weight and used to construct the corresponding homogeneous phantoms. 80 kVp x-rays with a mean energy of 47 keV was used in the simulation. A total of 109 photons were used to image the phantoms and the energies deposited in the phantom voxels were tallied. Breast doses in homogeneous phantoms were averaged over all voxels and then used to calculate the MGDs using the F-factors evaluated at the mean energy of the x-rays. The MGDs for quasi-homogeneous phantoms were computed directly by averaging the doses over all glandular tissue voxels. The MGDs estimated for the two types of phantoms were normalized to the free-in-air dose at the iso-center and compared. Results: The normalized MGDs were 0.756 and 0.732 mGy/mGy for the 25% and 50% VGF homogeneous breasts and 0.761 and 0.733 mGy/mGy for the corresponding quasi-homogeneous breasts, respectively. The MGDs estimated for the two types of phantoms were similar within 1% in this study. Conclusion: MGDs for homogeneous breast models may be adequately estimated by converting from the average breast dose using the F-factor.« less

  2. Monte Carlo generated conversion factors for the estimation of average glandular dose in contact and magnification mammography

    NASA Astrophysics Data System (ADS)

    Koutalonis, M.; Delis, H.; Spyrou, G.; Costaridou, L.; Tzanakos, G.; Panayiotakis, G.

    2006-11-01

    Magnification mammography is a special technique used in the cases where breast complaints are noted by a woman or when an abnormality is found in a screening mammogram. The carcinogenic risk in mammography is related to the dose deposited in the glandular tissue of the breast rather than the adipose, and average glandular dose (AGD) is the quantity taken into consideration during a mammographic examination. Direct measurement of the AGD is not feasible during clinical practice and thus, the incident air KERMA on the breast surface is used to estimate the glandular dose, with the help of proper conversion factors. Additional conversion factors adapted for magnification and tube voltage are calculated, using Monte Carlo simulation. The effect of magnification degree, tube voltage, various anode/filter material combinations and glandularity on AGD is also studied, considering partial breast irradiation. Results demonstrate that the estimation of AGD utilizing conversion factors depends on these parameters, while the omission of correction factors for magnification and tube voltage can lead to significant underestimation or overestimation of AGD. AGD was found to increase with filter material's k-absorption edge, anode material's k-emission edge, tube voltage and magnification. Decrease of the glandularity of the breast leads to higher AGD due to the increased penetrating ability of the photon beam in thick breasts with low glandularity.

  3. Reconstruction of Absorbed Doses to Fibroglandular Tissue of the Breast of Women undergoing Mammography (1960 to the Present)

    PubMed Central

    Thierry-Chef, Isabelle; Simon, Steven L.; Weinstock, Robert M.; Kwon, Deukwoo; Linet, Martha S.

    2013-01-01

    The assessment of potential benefits versus harms from mammographic examinations as described in the controversial breast cancer screening recommendations of the U.S. Preventive Task Force included limited consideration of absorbed dose to the fibroglandular tissue of the breast (glandular tissue dose), the tissue at risk for breast cancer. Epidemiological studies on cancer risks associated with diagnostic radiological examinations often lack accurate information on glandular tissue dose, and there is a clear need for better estimates of these doses. Our objective was to develop a quantitative summary of glandular tissue doses from mammography by considering sources of variation over time in key parameters including imaging protocols, x-ray target materials, voltage, filtration, incident air kerma, compressed breast thickness, and breast composition. We estimated the minimum, maximum, and mean values for glandular tissue dose for populations of exposed women within 5-year periods from 1960 to the present, with the minimum to maximum range likely including 90% to 95% of the entirety of the dose range from mammography in North America and Europe. Glandular tissue dose from a single view in mammography is presently about 2 mGy, about one-sixth the dose in the 1960s. The ratio of our estimates of maximum to minimum glandular tissue doses for average-size breasts was about 100 in the 1960s compared to a ratio of about 5 in recent years. Findings from our analysis provide quantitative information on glandular tissue doses from mammographic examinations which can be used in epidemiologic studies of breast cancer. PMID:21988547

  4. Monte Carlo evaluation of glandular dose in cone-beam X-ray computed tomography dedicated to the breast: Homogeneous and heterogeneous breast models.

    PubMed

    Sarno, Antonio; Mettivier, Giovanni; Tucciariello, Raffaele M; Bliznakova, Kristina; Boone, John M; Sechopoulos, Ioannis; Di Lillo, Francesca; Russo, Paolo

    2018-06-07

    In cone-beam computed tomography dedicated to the breast (BCT), the mean glandular dose (MGD) is the dose metric of reference, evaluated from the measured air kerma by means of normalized glandular dose coefficients (DgN CT ). This work aimed at computing, for a simple breast model, a set of DgN CT values for monoenergetic and polyenergetic X-ray beams, and at validating the results vs. those for patient specific digital phantoms from BCT scans. We developed a Monte Carlo code for calculation of monoenergetic DgN CT coefficients (energy range 4.25-82.25 keV). The pendant breast was modelled as a cylinder of a homogeneous mixture of adipose and glandular tissue with glandular fractions by mass of 0.1%, 14.3%, 25%, 50% or 100%, enveloped by a 1.45 mm-thick skin layer. The breast diameter ranged between 8 cm and 18 cm. Then, polyenergetic DgN CT coefficients were analytically derived for 49-kVp W-anode spectra (half value layer 1.25-1.50 mm Al), as in a commercial BCT scanner. We compared the homogeneous models to 20 digital phantoms produced from classified 3D breast images. Polyenergetic DgN CT resulted 13% lower than most recent published data. The comparison vs. patient specific breast phantoms showed that the homogeneous cylindrical model leads to a DgN CT percentage difference between -15% and +27%, with an average overestimation of 8%. A dataset of monoenergetic and polyenergetic DgN CT coefficients for BCT was provided. Patient specific breast models showed a different volume distribution of glandular dose and determined a DgN CT 8% lower, on average, than homogeneous breast model. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  5. Estimates of Average Glandular Dose with Auto-modes of X-ray Exposures in Digital Breast Tomosynthesis.

    PubMed

    Kamal, Izdihar; Chelliah, Kanaga K; Mustafa, Nawal

    2015-05-01

    The aim of this research was to examine the average glandular dose (AGD) of radiation among different breast compositions of glandular and adipose tissue with auto-modes of exposure factor selection in digital breast tomosynthesis. This experimental study was carried out in the National Cancer Society, Kuala Lumpur, Malaysia, between February 2012 and February 2013 using a tomosynthesis digital mammography X-ray machine. The entrance surface air kerma and the half-value layer were determined using a 100H thermoluminescent dosimeter on 50% glandular and 50% adipose tissue (50/50) and 20% glandular and 80% adipose tissue (20/80) commercially available breast phantoms (Computerized Imaging Reference Systems, Inc., Norfolk, Virginia, USA) with auto-time, auto-filter and auto-kilovolt modes. The lowest AGD for the 20/80 phantom with auto-time was 2.28 milliGray (mGy) for two dimension (2D) and 2.48 mGy for three dimensional (3D) images. The lowest AGD for the 50/50 phantom with auto-time was 0.97 mGy for 2D and 1.0 mGy for 3D. The AGD values for both phantoms were lower against a high kilovolt peak and the use of auto-filter mode was more practical for quick acquisition while limiting the probability of operator error.

  6. Assessment of Mean Glandular Dose in Mammography System with Different Anode-Filter Combinations Using MCNP Code.

    PubMed

    Gholamkar, Lida; Mowlavi, Ali Asghar; Sadeghi, Mahdi; Athari, Mitra

    2016-10-01

    X-ray mammography is one of the general methods for early detection of breast cancer. Since glandular tissue in the breast is sensitive to radiation and it increases the risk of cancer, the given dose to the patient is very important in mammography. The aim of this study was to determine the average absorbed dose of X-ray radiation in the glandular tissue of the breast during mammography examinations as well as investigating factors that influence the mean glandular dose (MGD). One of the precise methods for determination of MGD absorbed by the breast is Monte Carlo simulation method which is widely used to assess the dose. We studied some different X-ray sources and exposure factors that affect the MGD. "Midi-future" digital mammography system with amorphous-selenium detector was simulated using the Monte Carlo N-particle extended (MCNPX) code. Different anode/filter combinations such as tungsten/silver (W/Ag), tungsten/rhodium (W/Rh), and rhodium/aluminium (Rh/Al) were simulated in this study. The voltage of X-ray tube ranged from 24 kV to 32 kV with 2 kV intervals and the breast phantom thickness ranged from 3 to 8 cm, and glandular fraction g varied from 10% to 100%. MGD was measured for different anode/filter combinations and the effects of changing tube voltage, phantom thickness, combination and glandular breast tissue on MGD were studied. As glandular g and X-ray tube voltage increased, the breast dose increased too, and the increase of breast phantom thickness led to the decrease of MGD. The obtained results for MGD were consistent with the result of Boone et al. that was previously reported. By comparing the results, we saw that W/Rh anode/filter combination is the best choice in breast mammography imaging because of the lowest delivered dose in comparison with W/Ag and Rh/Al. Moreover, breast thickness and g value have significant effects on MGD.

  7. Assessment of Mean Glandular Dose in Mammography System with Different Anode-Filter Combinations Using MCNP Code

    PubMed Central

    Gholamkar, Lida; Mowlavi, Ali Asghar; Sadeghi, Mahdi; Athari, Mitra

    2016-01-01

    Background X-ray mammography is one of the general methods for early detection of breast cancer. Since glandular tissue in the breast is sensitive to radiation and it increases the risk of cancer, the given dose to the patient is very important in mammography. Objectives The aim of this study was to determine the average absorbed dose of X-ray radiation in the glandular tissue of the breast during mammography examinations as well as investigating factors that influence the mean glandular dose (MGD). One of the precise methods for determination of MGD absorbed by the breast is Monte Carlo simulation method which is widely used to assess the dose. Materials and Methods We studied some different X-ray sources and exposure factors that affect the MGD. “Midi-future” digital mammography system with amorphous-selenium detector was simulated using the Monte Carlo N-particle extended (MCNPX) code. Different anode/filter combinations such as tungsten/silver (W/Ag), tungsten/rhodium (W/Rh), and rhodium/aluminium (Rh/Al) were simulated in this study. The voltage of X-ray tube ranged from 24 kV to 32 kV with 2 kV intervals and the breast phantom thickness ranged from 3 to 8 cm, and glandular fraction g varied from 10% to 100%. Results MGD was measured for different anode/filter combinations and the effects of changing tube voltage, phantom thickness, combination and glandular breast tissue on MGD were studied. As glandular g and X-ray tube voltage increased, the breast dose increased too, and the increase of breast phantom thickness led to the decrease of MGD. The obtained results for MGD were consistent with the result of Boone et al. that was previously reported. Conclusion By comparing the results, we saw that W/Rh anode/filter combination is the best choice in breast mammography imaging because of the lowest delivered dose in comparison with W/Ag and Rh/Al. Moreover, breast thickness and g value have significant effects on MGD. PMID:27895876

  8. Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT

    NASA Astrophysics Data System (ADS)

    Angel, Erin; Yaghmai, Nazanin; Matilda Jude, Cecilia; DeMarco, John J.; Cagnon, Christopher H.; Goldin, Jonathan G.; Primak, Andrew N.; Stevens, Donna M.; Cody, Dianna D.; McCollough, Cynthia H.; McNitt-Gray, Michael F.

    2009-02-01

    Tube current modulation was designed to reduce radiation dose in CT imaging while maintaining overall image quality. This study aims to develop a method for evaluating the effects of tube current modulation (TCM) on organ dose in CT exams of actual patient anatomy. This method was validated by simulating a TCM and a fixed tube current chest CT exam on 30 voxelized patient models and estimating the radiation dose to each patient's glandular breast tissue. This new method for estimating organ dose was compared with other conventional estimates of dose reduction. Thirty detailed voxelized models of patient anatomy were created based on image data from female patients who had previously undergone clinically indicated CT scans including the chest area. As an indicator of patient size, the perimeter of the patient was measured on the image containing at least one nipple using a semi-automated technique. The breasts were contoured on each image set by a radiologist and glandular tissue was semi-automatically segmented from this region. Previously validated Monte Carlo models of two multidetector CT scanners were used, taking into account details about the source spectra, filtration, collimation and geometry of the scanner. TCM data were obtained from each patient's clinical scan and factored into the model to simulate the effects of TCM. For each patient model, two exams were simulated: a fixed tube current chest CT and a tube current modulated chest CT. X-ray photons were transported through the anatomy of the voxelized patient models, and radiation dose was tallied in the glandular breast tissue. The resulting doses from the tube current modulated simulations were compared to the results obtained from simulations performed using a fixed mA value. The average radiation dose to the glandular breast tissue from a fixed tube current scan across all patient models was 19 mGy. The average reduction in breast dose using the tube current modulated scan was 17%. Results were size dependent with smaller patients getting better dose reduction (up to 64% reduction) and larger patients getting a smaller reduction, and in some cases the dose actually increased when using tube current modulation (up to 41% increase). The results indicate that radiation dose to glandular breast tissue generally decreases with the use of tube current modulated CT acquisition, but that patient size (and in some cases patient positioning) may affect dose reduction.

  9. Mean glandular dose to patients from stereotactic breast biopsy procedures.

    PubMed

    Paixão, Lucas; Chevalier, Margarita; Hurtado-Romero, Antonio E; Garayoa, Julia

    2018-06-07

    The aim of this work is to study the radiation doses delivered to a group of patients that underwent a stereotactic breast biopsy (SBB) procedure. Mean glandular doses (MGD) were estimated from the air-kerma measured at the breast surface entrance multiplying by specific conversion coefficients (DgN) that were estimated using Monte Carlo simulations. DgN were calculated for the 0º and ±15º projections used in SBB and for the particular beam quality. Data on 61 patients were collected showing that a typical SBB procedure is composed by 10 images. MGD was on average (4 ± 2) mGy with (0.38 ± 0.06) mGy per image. The use of specific conversion coefficients instead of typical DgN for mammography/tomosynthesis yields to obtain MGD values for SBB that are around a 65% lower on average. © 2018 Institute of Physics and Engineering in Medicine.

  10. Effect of filter on average glandular dose and image quality in digital mammography

    NASA Astrophysics Data System (ADS)

    Songsaeng, C.; Krisanachinda, A.; Theerakul, K.

    2016-03-01

    To determine the average glandular dose and entrance surface air kerma in both phantoms and patients to assess image quality for different target-filters (W/Rh and W/Ag) in digital mammography system. The compressed breast thickness, compression force, average glandular dose, entrance surface air kerma, peak kilovoltage and tube current time were recorded and compared between W/Rh and W/Ag target filter. The CNR and the figure of merit were used to determine the effect of target filter on image quality. The mean AGD of the W/Rh target filter was 1.75 mGy, the mean ESAK was 6.67 mGy, the mean CBT was 54.1 mm, the mean CF was 14 1bs. The mean AGD of W/Ag target filter was 2.7 mGy, the mean ESAK was 12.6 mGy, the mean CBT was 75.5 mm, the mean CF was 15 1bs. In phantom study, the AGD was 1.2 mGy at 4 cm, 3.3 mGy at 6 cm and 3.83 mGy at 7 cm thickness. The FOM was 24.6, CNR was 9.02 at thickness 6 cm. The FOM was 18.4, CNR was 8.6 at thickness 7 cm. The AGD from Digital Mammogram system with W/Rh of thinner CBT was lower than the AGD from W/Ag target filter.

  11. SU-F-I-53: Coded Aperture Coherent Scatter Spectral Imaging of the Breast: A Monte Carlo Evaluation of Absorbed Dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morris, R; Lakshmanan, M; Fong, G

    Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scanmore » protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to a minimum while still maintaining clinically viable image quality.« less

  12. Breast dose in mammography is about 30% lower when realistic heterogeneous glandular distributions are considered

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hernandez, Andrew M., E-mail: amhern@ucdavis.edu; Seibert, J. Anthony; Boone, John M.

    2015-11-15

    Purpose: Current dosimetry methods in mammography assume that the breast is comprised of a homogeneous mixture of glandular and adipose tissues. Three-dimensional (3D) dedicated breast CT (bCT) data sets were used previously to assess the complex anatomical structure within the breast, characterizing the statistical distribution of glandular tissue in the breast. The purpose of this work was to investigate the effect of bCT-derived heterogeneous glandular distributions on dosimetry in mammography. Methods: bCT-derived breast diameters, volumes, and 3D fibroglandular distributions were used to design realistic compressed breast models comprised of heterogeneous distributions of glandular tissue. The bCT-derived glandular distributions were fitmore » to biGaussian functions and used as probability density maps to assign the density distributions within compressed breast models. The MCNPX 2.6.0 Monte Carlo code was used to estimate monoenergetic normalized mean glandular dose “DgN(E)” values in mammography geometry. The DgN(E) values were then weighted by typical mammography x-ray spectra to determine polyenergetic DgN (pDgN) coefficients for heterogeneous (pDgN{sub hetero}) and homogeneous (pDgN{sub homo}) cases. The dependence of estimated pDgN values on phantom size, volumetric glandular fraction (VGF), x-ray technique factors, and location of the heterogeneous glandular distributions was investigated. Results: The pDgN{sub hetero} coefficients were on average 35.3% (SD, 4.1) and 24.2% (SD, 3.0) lower than the pDgN{sub homo} coefficients for the Mo–Mo and W–Rh x-ray spectra, respectively, across all phantom sizes and VGFs when the glandular distributions were centered within the breast phantom in the coronal plane. At constant breast size, increasing VGF from 7.3% to 19.1% lead to a reduction in pDgN{sub hetero} relative to pDgN{sub homo} of 23.6%–27.4% for a W–Rh spectrum. Displacement of the glandular distribution, at a distance equal to 10% of the compressed breast width in the superior and inferior directions, resulted in a 37.3% and a −26.6% change in the pDgN{sub hetero} coefficient, respectively, relative to the centered distribution for the Mo–Mo spectrum. Lateral displacement of the glandular distribution, at a distance equal to 10% of the compressed breast width, resulted in a 1.5% change in the pDgN{sub hetero} coefficient relative to the centered distribution for the W–Rh spectrum. Conclusions: Introducing bCT-derived heterogeneous glandular distributions into mammography phantom design resulted in decreased glandular dose relative to the widely used homogeneous assumption. A homogeneous distribution overestimates the amount of glandular tissue near the entrant surface of the breast, where dose deposition is exponentially higher. While these findings are based on clinically measured distributions of glandular tissue using a large cohort of women, future work is required to improve the classification of glandular distributions based on breast size and overall glandular fraction.« less

  13. Validation of Monte Carlo simulation of mammography with TLD measurement and depth dose calculation with a detailed breast model

    NASA Astrophysics Data System (ADS)

    Wang, Wenjing; Qiu, Rui; Ren, Li; Liu, Huan; Wu, Zhen; Li, Chunyan; Li, Junli

    2017-09-01

    Mean glandular dose (MGD) is not only determined by the compressed breast thickness (CBT) and the glandular content, but also by the distribution of glandular tissues in breast. Depth dose inside the breast in mammography has been widely concerned as glandular dose decreases rapidly with increasing depth. In this study, an experiment using thermo luminescent dosimeters (TLDs) was carried out to validate Monte Carlo simulations of mammography. Percent depth doses (PDDs) at different depth values were measured inside simple breast phantoms of different thicknesses. The experimental values were well consistent with the values calculated by Geant4. Then a detailed breast model with a CBT of 4 cm and a glandular content of 50%, which has been constructed in previous work, was used to study the effects of the distribution of glandular tissues in breast with Geant4. The breast model was reversed in direction of compression to get a reverse model with a different distribution of glandular tissues. Depth dose distributions and glandular tissue dose conversion coefficients were calculated. It revealed that the conversion coefficients were about 10% larger when the breast model was reversed, for glandular tissues in the reverse model are concentrated in the upper part of the model.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong, Shang-Lung; Chu, Tieh-Chi; Lin, Yung-Chien

    Purpose: Polymethylmethacrylate (PMMA) slab is one of the mostly used phantoms for studying breast dosimetry in mammography. The purpose of this study was to evaluate the equivalence between exposure factors acquired from PMMA slabs and patient cases of different age groups of Taiwanese women in mammography. Methods: This study included 3910 craniocaudal screen/film mammograms on Taiwanese women acquired on one mammographic unit. The tube loading, compressed breast thickness (CBT), compression force, tube voltage, and target/filter combination for each mammogram were collected for all patients. The glandularity and the equivalent thickness of PMMA were determined for each breast using the exposuremore » factors of the breast in combination with experimental measurements from breast-tissue-equivalent attenuation slabs. Equivalent thicknesses of PMMA to the breasts of Taiwanese women were then estimated. Results: The average {+-} standard deviation CBT and breast glandularity in this study were 4.2 {+-} 1.0 cm and 54% {+-} 23%, respectively. The average equivalent PMMA thickness was 4.0 {+-} 0.7 cm. PMMA slabs producing equivalent exposure factors as in the breasts of Taiwanese women were determined for the age groups 30-49 yr and 50-69 yr. For the 4-cm PMMA slab, the CBT and glandularity values of the equivalent breast were 4.1 cm and 65%, respectively, for the age group 30-49 yr and 4.4 cm and 44%, respectively, for the age group 50-69 yr. Conclusions: The average thickness of PMMA slabs producing the same exposure factors as observed in a large group of Taiwanese women is less than that reported for American women. The results from this study can provide useful information for determining a suitable thickness of PMMA for mammographic dose survey in Taiwan. The equivalence of PMMA slabs and the breasts of Taiwanese women is provided to allow average glandular dose assessment in clinical practice.« less

  15. TLD measurements of in vivo mammographic exposures and the calculated mean glandular dose across the United States.

    PubMed

    Gentry, J R; DeWerd, L A

    1996-06-01

    An analysis is presented of the exposures received by TLDs placed on the breasts of 4400 women obtaining mammograms at 170 institutions across the United States. Mean glandular dose and exposure were examined as a function of compressed breast thickness. The exposure and mean glandular dose were found to increase linearly with breast thickness. The mean glandular dose typically delivered by the institutions was well below the limit of 3.0 mGy for the 4.5-cm breast. However, some institutions tend to uniformly give higher doses. In such institutions approximately 25% of 4.5-cm-thick breasts received a mean glandular dose exceeding 3.0 mGy.

  16. A comparison of two doses of omeprazole in the treatment of equine gastric ulcer syndrome: a blinded, randomised, clinical trial.

    PubMed

    Sykes, B W; Sykes, K M; Hallowell, G D

    2014-07-01

    Studies on omeprazole have reported that doses as low as 0.7 mg/kg bwt per os are potent suppressors of acid production. Yet, to date, no studies have compared treatment efficacy of different doses in clinical cases of equine gastric ulceration. Furthermore, no studies have been performed to compare the healing response of the squamous and glandular mucosa to acid suppression therapy. To compare: 1) the efficacy of 2 doses of omeprazole in the treatment of primary squamous and glandular gastric ulceration; and 2) the healing response of primary squamous and glandular gastric ulceration to acid suppression therapy. A blinded, randomised, dose-response clinical trial. Twenty Thoroughbred racehorses with grade ≥2/4 glandular ulceration were identified on gastroscopy. Seventeen horses also had grade ≥2/4 squamous ulceration. Horses were randomly assigned to one of 2 groups. Horses received either 2.0 g (high dose: 4.0 mg/kg bwt) or 0.8 g (low dose: 1.6 mg/kg bwt) of oral omeprazole per os once daily. Gastroscopy was repeated at 28-35 days. Time and dose significantly affected grades of squamous (P<0.0001, P = 0.02) and glandular (P = 0.006 and 0.005) ulceration. Data analysis did not support our hypothesis that the lower dose would have similar effects (i.e. be noninferior) to the higher dose when considering ulcer healing and ulcer improvement. Improvement was more likely with the high dose for the squamous (P = 0.05) but not glandular (P = 0.4) mucosa. The percentage of glandular ulcers that improved was less than squamous ulcers (P = 0.02). The results suggest that a dose-response exists for the treatment of both squamous and glandular ulcers. Improvement of glandular ulcers was not as complete as observed with squamous ulcers and current equine gastric ulcer syndrome treatment recommendations may not be appropriate for glandular disease. © 2013 EVJ Ltd.

  17. New method for generating breast models featuring glandular tissue spatial distribution

    NASA Astrophysics Data System (ADS)

    Paixão, L.; Oliveira, B. B.; Oliveira, M. A.; Teixeira, M. H. A.; Fonseca, T. C. F.; Nogueira, M. S.

    2016-02-01

    Mammography is the main radiographic technique used for breast imaging. A major concern with mammographic imaging is the risk of radiation-induced breast cancer due to the high sensitivity of breast tissue. The mean glandular dose (DG) is the dosimetric quantity widely accepted to characterize the risk of radiation induced cancer. Previous studies have concluded that DG depends not only on the breast glandular content but also on the spatial distribution of glandular tissue within the breast. In this work, a new method for generating computational breast models featuring skin composition and glandular tissue distribution from patients undergoing digital mammography is proposed. Such models allow a more accurate way of calculating individualized breast glandular doses taking into consideration the glandular tissue fraction. Sixteen breast models of four patients with different glandularity breasts were simulated and the results were compared with those obtained from recommended DG conversion factors. The results show that the internationally recommended conversion factors may be overestimating the mean glandular dose to less dense breasts and underestimating the mean glandular dose for denser breasts. The methodology described in this work constitutes a powerful tool for breast dosimetry, especially for risk studies.

  18. TL dosimetry for quality control of CR mammography imaging systems

    NASA Astrophysics Data System (ADS)

    Gaona, E.; Nieto, J. A.; Góngora, J. A. I. D.; Arreola, M.; Enríquez, J. G. F.

    The aim of this work is to estimate the average glandular dose with thermoluminescent (TL) dosimetry and comparison with quality imaging in computed radiography (CR) mammography. For a measuring dose, the Food and Drug Administration (FDA) and the American College of Radiology (ACR) use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, full field digital mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium flourohalideE We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated X-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose greater than 3.0 mGy without demonstrating improved image quality. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement for X-rays with a HVL (0.35-0.38 mmAl) and kVp (24-26) used in quality control procedures with ACR Mammography Accreditation Phantom.

  19. Average glandular dose in paired digital mammography and digital breast tomosynthesis acquisitions in a population based screening program: effects of measuring breast density, air kerma and beam quality

    NASA Astrophysics Data System (ADS)

    Helge Østerås, Bjørn; Skaane, Per; Gullien, Randi; Catrine Trægde Martinsen, Anne

    2018-02-01

    The main purpose was to compare average glandular dose (AGD) for same-compression digital mammography (DM) and digital breast tomosynthesis (DBT) acquisitions in a population based screening program, with and without breast density stratification, as determined by automatically calculated breast density (Quantra™). Secondary, to compare AGD estimates based on measured breast density, air kerma and half value layer (HVL) to DICOM metadata based estimates. AGD was estimated for 3819 women participating in the screening trial. All received craniocaudal and mediolateral oblique views of each breasts with paired DM and DBT acquisitions. Exposure parameters were extracted from DICOM metadata. Air kerma and HVL were measured for all beam qualities used to acquire the mammograms. Volumetric breast density was estimated using Quantra™. AGD was estimated using the Dance model. AGD reported directly from the DICOM metadata was also assessed. Mean AGD was 1.74 and 2.10 mGy for DM and DBT, respectively. Mean DBT/DM AGD ratio was 1.24. For fatty breasts: mean AGD was 1.74 and 2.27 mGy for DM and DBT, respectively. For dense breasts: mean AGD was 1.73 and 1.79 mGy, for DM and DBT, respectively. For breasts of similar thickness, dense breasts had higher AGD for DM and similar AGD for DBT. The DBT/DM dose ratio was substantially lower for dense compared to fatty breasts (1.08 versus 1.33). The average c-factor was 1.16. Using previously published polynomials to estimate glandularity from thickness underestimated the c-factor by 5.9% on average. Mean AGD error between estimates based on measurements (air kerma and HVL) versus DICOM header data was 3.8%, but for one mammography unit as high as 7.9%. Mean error of using the AGD value reported in the DICOM header was 10.7 and 13.3%, respectively. Thus, measurement of breast density, radiation dose and beam quality can substantially affect AGD estimates.

  20. Average glandular dose in paired digital mammography and digital breast tomosynthesis acquisitions in a population based screening program: effects of measuring breast density, air kerma and beam quality.

    PubMed

    Østerås, Bjørn Helge; Skaane, Per; Gullien, Randi; Martinsen, Anne Catrine Trægde

    2018-01-25

    The main purpose was to compare average glandular dose (AGD) for same-compression digital mammography (DM) and digital breast tomosynthesis (DBT) acquisitions in a population based screening program, with and without breast density stratification, as determined by automatically calculated breast density (Quantra ™ ). Secondary, to compare AGD estimates based on measured breast density, air kerma and half value layer (HVL) to DICOM metadata based estimates. AGD was estimated for 3819 women participating in the screening trial. All received craniocaudal and mediolateral oblique views of each breasts with paired DM and DBT acquisitions. Exposure parameters were extracted from DICOM metadata. Air kerma and HVL were measured for all beam qualities used to acquire the mammograms. Volumetric breast density was estimated using Quantra ™ . AGD was estimated using the Dance model. AGD reported directly from the DICOM metadata was also assessed. Mean AGD was 1.74 and 2.10 mGy for DM and DBT, respectively. Mean DBT/DM AGD ratio was 1.24. For fatty breasts: mean AGD was 1.74 and 2.27 mGy for DM and DBT, respectively. For dense breasts: mean AGD was 1.73 and 1.79 mGy, for DM and DBT, respectively. For breasts of similar thickness, dense breasts had higher AGD for DM and similar AGD for DBT. The DBT/DM dose ratio was substantially lower for dense compared to fatty breasts (1.08 versus 1.33). The average c-factor was 1.16. Using previously published polynomials to estimate glandularity from thickness underestimated the c-factor by 5.9% on average. Mean AGD error between estimates based on measurements (air kerma and HVL) versus DICOM header data was 3.8%, but for one mammography unit as high as 7.9%. Mean error of using the AGD value reported in the DICOM header was 10.7 and 13.3%, respectively. Thus, measurement of breast density, radiation dose and beam quality can substantially affect AGD estimates.

  1. Contrast-enhanced dual-energy digital subtraction mammography: optimization of the beam energy

    NASA Astrophysics Data System (ADS)

    Kwan, Alexander L. C.; Boone, John M.; Le-Petross, Huong; Lindfors, Karen K.; Seibert, J. A.; Lewin, John M.

    2005-04-01

    The implementation of contrast-enhanced dual-energy digital subtraction mammography may lead to better identification of breast tumors, and thus provide a lower cost and more widely available alternative to breast MRI. This technique involves the acquisition of low- and high-energy images after the IV administration of iodinated contrast agent. In this study, the effect of the beam energy (kVp) was examined using the CNR2/dose metric, where CNR is the contrast-to-noise ratio and dose implies the mean glandular dose. The mean glandular dose was calculated using parameterized normalized glandular dose coefficients (DgN), which allowed the computation of the mean glandular dose for the modeled spectra considered in this study, coupled with incident kerma measurements. Optimization studies were performed using a dedicated cone-beam breast CT scanner designed and fabricated in our laboratory, with the system operating in stationary imaging mode. A flat tissue-equivalent phantom (7.5 cm in thickness) was placed at the isocenter of the scanner, and an air gap of 34.5 cm was used in lieu of a grid. Dilute iodine-based contrast agent was introduced into the phantoms using plastic vials. Data were acquired from 40 to 90 kVp at 10 kVp intervals. Due to the low mA available on the breast CT system, a large number of images (1000) were acquired in fluoroscopic mode, which allowed us to match the dose and noise properties for each kVp combinations by changing the number of images used for averaging. Preliminary results demonstrate that the best CNR2/dose is achieved with a 50 kVp low-energy image and a 90 kVp high-energy image. Consequently, radiation doses for contrast-enhanced mammography should be far lower than regular mammography. Since the spatial resolution requirements should also be lower than regular mammography, dual-energy contrast-enhanced mammography, when performed using the optimal technique factor, may indeed provide very similar diagnostic information as breast MRI but at significantly reduced costs.

  2. [Radiation dose evaluation in a photon-counting digital mammography unit].

    PubMed

    Matsubara, Kosuke; Matsumoto, China; Mochiya, Yuko; Toda, Kanako; Noto, Kimiya; Koshida, Kichiro

    2014-05-01

    The purpose of our study was to evaluate radiation dose and beam quality in photon-counting digital mammography (PCDM) and compare them with those in a full-field digital mammography (FFDM) unit. Dose variation in the X-ray tube axis direction, aluminum half-value layer, average glandular and skin doses, and contrast-to-noise ratio (CNR) were evaluated for the PCDM and FFDM units. In PCDM, the dose variation in the X-ray tube axis direction was greater than that in FFDM. At a tube voltage of 28 kV, the first half-value layers were 0.407 mmAl for PCDM, 0.357 mmAl for FFDM with a molybdenum target and molybdenum filter (Mo/Mo), and 0.579 mmAl for FFDM with a tungsten target and rhodium filter (W/Rh). The average glandular doses with 45-mm-equivalent breast thickness were 0.723 mGy for the PCDM, 1.55 mGy for the FFDM with Mo/Mo in low-dose mode, and 0.835 mGy for the FFDM with W/Rh in low-dose mode. In PCDM, the skin dose was equivalent to or lower than that in FFDM. The CNR was 2.65±0.04, 2.35±0.04, and 2.52±0.03 for the PCDM, FFDM with Mo/Mo, and that with W/Rh, respectively. The CNR for PCDM was significantly higher than that for FFDM (p<0.001). It is therefore possible to reduce the radiation dose to the patient by using a PCDM unit while maintaining a significantly higher CNR than with the FFDM unit.

  3. Glandular radiation dose in tomosynthesis of the breast using tungsten targets.

    PubMed

    Sechopoulos, Ioannis; D'Orsi, Carl J

    2008-10-24

    With the advent of new detector technology, digital tomosynthesis imaging of the breast has, in the past few years, become a technique intensely investigated as a replacement for planar mammography. As with all other x-ray-based imaging methods, radiation dose is of utmost concern in the development of this new imaging technology. For virtually all development and optimization studies, knowledge of the radiation dose involved in an imaging protocol is necessary. A previous study characterized the normalized glandular dose in tomosynthesis imaging and its variation with various breast and imaging system parameters. This characterization was performed with x-ray spectra generated by molybdenum and rhodium targets. In the recent past, many preliminary patient studies of tomosynthesis imaging have been reported in which the x-ray spectra were generated with x-ray tubes with tungsten targets. The differences in x-ray distribution among spectra from these target materials make the computation of new normalized glandular dose values for tungsten target spectra necessary. In this study we used previously obtained monochromatic normalized glandular dose results to obtain spectral results for twelve different tungsten target x-ray spectra. For each imaging condition, two separate values were computed: the normalized glandular dose for the zero degree projection angle (DgN0), and the ratio of the glandular dose for non-zero projection angles to the glandular dose for the zero degree projection (the relative glandular dose, RGD(alpha)). It was found that DgN0 is higher for tungsten target x-ray spectra when compared with DgN0 values for molybdenum and rhodium target spectra of both equivalent tube voltage and first half value layer. Therefore, the DgN0 for the twelve tungsten target x-ray spectra and different breast compositions and compressed breast thicknesses simulated are reported. The RGD(alpha) values for the tungsten spectra vary with the parameters studied in a similar manner to that found for the molybdenum and rhodium target spectra. The surface fit equations and the fit coefficients for RGD(alpha) included in the previous study were also found to be appropriate for the tungsten spectra.

  4. Radiation exposure of contrast-enhanced spectral mammography compared with full-field digital mammography.

    PubMed

    Jeukens, Cécile R L P N; Lalji, Ulrich C; Meijer, Eduard; Bakija, Betina; Theunissen, Robin; Wildberger, Joachim E; Lobbes, Marc B I

    2014-10-01

    Contrast-enhanced spectral mammography (CESM) shows promising initial results but comes at the cost of increased dose as compared with full-field digital mammography (FFDM). We aimed to quantitatively assess the dose increase of CESM in comparison with FFDM. Radiation exposure-related data (such as kilovoltage, compressed breast thickness, glandularity, entrance skin air kerma (ESAK), and average glandular dose (AGD) were retrieved for 47 CESM and 715 FFDM patients. All examinations were performed on 1 mammography unit. Radiation dose values reported by the unit were validated by phantom measurements. Descriptive statistics of the patient data were generated using a statistical software package. Dose values reported by the mammography unit were in good qualitative agreement with those of phantom measurements. Mean ESAK was 10.5 mGy for a CESM exposure and 7.46 mGy for an FFDM exposure. Mean AGD for a CESM exposure was 2.80 mGy and 1.55 mGy for an FFDM exposure. Compared with our institutional FFDM, the AGD of a single CESM exposure is increased by 1.25 mGy (+81%), whereas ESAK is increased by 3.07 mGy (+41%). Dose values of both techniques meet the recommendations for maximum dose in mammography.

  5. SU-F-I-01: Normalized Mean Glandular Dose Values for Dedicated Breast CT Using Realistic Breast-Shaped Phantoms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hernandez, A; Boone, J

    Purpose: To estimate normalized mean glandular dose values for dedicated breast CT (DgN-CT) using breast CT-derived phantoms and compare to estimations using cylindrical phantoms. Methods: Segmented breast CT (bCT) volume data sets (N=219) were used to measure effective diameter profiles and were grouped into quintiles by volume. The profiles were averaged within each quintile to represent the range of breast sizes found clinically. These profiles were then used to generate five voxelized computational phantoms (V1, V2, V3, V4, V5 for the small to large phantom sizes, respectively), and loaded into the MCNP6 lattice geometry to simulate normalized mean glandular dosemore » coefficients (DgN-CT) using the system specifications of the Doheny-prototype bCT scanner in our laboratory. The DgN-CT coefficients derived from the bCT-derived breast-shaped phantoms were compared to those generated using a simpler cylindrical phantom using a constant volume, and the following constraints: (1) Length=1.5*radius; (2) radius determined at chest wall (Rcw), and (3) radius determined at the phantom center-of-mass (Rcm). Results: The change in Dg-NCT coefficients averaged across all phantom sizes, was - 0.5%, 19.8%, and 1.3%, for constraints 1–3, respectively. This suggests that the cylindrical assumption is a good approximation if the radius is taken at the breast center-of-mass, but using the radius at the chest wall results in an underestimation of the glandular dose. Conclusion: The DgN-CT coefficients for bCT-derived phantoms were compared against the assumption of a cylindrical phantom and proved to be essentially equivalent when the cylinder radius was set to r=1.5/L or Rcm. While this suggests that for dosimetry applications a patient’s breast can be approximated as a cylinder (if the correct radius is applied), this assumes a homogenous composition of breast tissue and the results may be different if the realistic heterogeneous distribution of glandular tissue is considered. Research reported in this paper was supported in part by the National Cancer Institute of the National Institutes of Health under award R01CA181081. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institue of Health.« less

  6. A parameterization method and application in breast tomosynthesis dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Xinhua; Zhang, Da; Liu, Bob

    2013-09-15

    Purpose: To present a parameterization method based on singular value decomposition (SVD), and to provide analytical parameterization of the mean glandular dose (MGD) conversion factors from eight references for evaluating breast tomosynthesis dose in the Mammography Quality Standards Act (MQSA) protocol and in the UK, European, and IAEA dosimetry protocols.Methods: MGD conversion factor is usually listed in lookup tables for the factors such as beam quality, breast thickness, breast glandularity, and projection angle. The authors analyzed multiple sets of MGD conversion factors from the Hologic Selenia Dimensions quality control manual and seven previous papers. Each data set was parameterized usingmore » a one- to three-dimensional polynomial function of 2–16 terms. Variable substitution was used to improve accuracy. A least-squares fit was conducted using the SVD.Results: The differences between the originally tabulated MGD conversion factors and the results computed using the parameterization algorithms were (a) 0.08%–0.18% on average and 1.31% maximum for the Selenia Dimensions quality control manual, (b) 0.09%–0.66% on average and 2.97% maximum for the published data by Dance et al. [Phys. Med. Biol. 35, 1211–1219 (1990); ibid. 45, 3225–3240 (2000); ibid. 54, 4361–4372 (2009); ibid. 56, 453–471 (2011)], (c) 0.74%–0.99% on average and 3.94% maximum for the published data by Sechopoulos et al. [Med. Phys. 34, 221–232 (2007); J. Appl. Clin. Med. Phys. 9, 161–171 (2008)], and (d) 0.66%–1.33% on average and 2.72% maximum for the published data by Feng and Sechopoulos [Radiology 263, 35–42 (2012)], excluding one sample in (d) that does not follow the trends in the published data table.Conclusions: A flexible parameterization method is presented in this paper, and was applied to breast tomosynthesis dosimetry. The resultant data offer easy and accurate computations of MGD conversion factors for evaluating mean glandular breast dose in the MQSA protocol and in the UK, European, and IAEA dosimetry protocols. Microsoft Excel™ spreadsheets are provided for the convenience of readers.« less

  7. Dosimetry and image quality assessment in a direct radiography system

    PubMed Central

    Oliveira, Bruno Beraldo; de Oliveira, Marcio Alves; Paixão, Lucas; Teixeira, Maria Helena Araújo; Nogueira, Maria do Socorro

    2014-01-01

    Objective To evaluate the mean glandular dose with a solid state detector and the image quality in a direct radiography system, utilizing phantoms. Materials and Methods Irradiations were performed with automatic exposure control and polymethyl methacrylate slabs with different thicknesses to calculate glandular dose values. The image quality was evaluated by means of the structures visualized on the images of the phantoms. Results Considering the uncertainty of the measurements, the mean glandular dose results are in agreement with the values provided by the equipment and with internationally adopted reference levels. Results obtained from images of the phantoms were in agreement with the reference values. Conclusion The present study contributes to verify the equipment conformity as regards dose values and image quality. PMID:25741119

  8. Mean glandular dose coefficients (D(g)N) for x-ray spectra used in contemporary breast imaging systems.

    PubMed

    Nosratieh, Anita; Hernandez, Andrew; Shen, Sam Z; Yaffe, Martin J; Seibert, J Anthony; Boone, John M

    2015-09-21

    To develop tables of normalized glandular dose coefficients D(g)N for a range of anode-filter combinations and tube voltages used in contemporary breast imaging systems. Previously published mono-energetic D(g)N values were used with various spectra to mathematically compute D(g)N coefficients. The tungsten anode spectra from TASMICS were used; molybdenum and rhodium anode-spectra were generated using MCNPX Monte Carlo code. The spectra were filtered with various thicknesses of Al, Rh, Mo or Cu. An initial half value layer (HVL) calculation was made using the anode and filter material. A range of the HVL values was produced with the addition of small thicknesses of polymethyl methacrylate (PMMA) as a surrogate for the breast compression paddle, to produce a range of HVL values at each tube voltage. Using a spectral weighting method, D(g)N coefficients for the generated spectra were calculated for breast glandular densities of 0%, 12.5%, 25%, 37.5%, 50% and 100% for a range of compressed breast thicknesses from 3 to 8 cm. Eleven tables of normalized glandular dose (D(g)N) coefficients were produced for the following anode/filter combinations: W + 50 μm Ag, W + 500 μm Al, W + 700 μm Al, W + 200 μm Cu, W + 300 μm Cu, W + 50 μm Rh, Mo + 400 μm Cu, Mo + 30 μm Mo, Mo + 25 μm Rh, Rh + 400 μm Cu and Rh + 25 μm Rh. Where possible, these results were compared to previously published D(g)N values and were found to be on average less than 2% different than previously reported values.Over 200 pages of D(g)N coefficients were computed for modeled x-ray system spectra that are used in a number of new breast imaging applications. The reported values were found to be in excellent agreement when compared to published values.

  9. Mean Glandular dose coefficients (DgN) for x-ray spectra used in contemporary breast imaging systems

    PubMed Central

    Nosratieh, Anita; Hernandez, Andrew; Shen, Sam Z.; Yaffe, Martin J.; Seibert, J. Anthony; Boone, John M.

    2015-01-01

    Purpose To develop tables of normalized glandular dose coefficients DgN for a range of anode–filter combinations and tube voltages used in contemporary breast imaging systems. Methods Previously published mono-energetic DgN values were used with various spectra to mathematically compute DgN coefficients. The tungsten anode spectra from TASMICS were used; Molybdenum and Rhodium anode-spectra were generated using MCNPx Monte Carlo code. The spectra were filtered with various thicknesses of Al, Rh, Mo or Cu. An initial HVL calculation was made using the anode and filter material. A range of the HVL values was produced with the addition of small thicknesses of polymethyl methacrylate (PMMA) as a surrogate for the breast compression paddle, to produce a range of HVL values at each tube voltage. Using a spectral weighting method, DgN coefficients for the generated spectra were calculated for breast glandular densities of 0%, 12.5%, 25%, 37.5%, 50% and 100% for a range of compressed breast thicknesses from 3 to 8 cm. Results Eleven tables of normalized glandular dose (DgN) coefficients were produced for the following anode/filter combinations: W + 50 μm Ag, W + 500 μm Al, W + 700 μm Al, W + 200 μm Cu, W + 300 μm Cu, W + 50 μm Rh, Mo + 400 μm Cu, Mo + 30 μm Mo, Mo + 25 μm Rh, Rh + 400 μm Cu and Rh + 25 μm Rh. Where possible, these results were compared to previously published DgN values and were found to be on average less than 2% different than previously reported values. Conclusion Over 200-pages of DgN coefficients were computed for modeled x-ray system spectra that are used in a number of new breast imaging applications. The reported values were found to be in excellent agreement when compared to published values. PMID:26348995

  10. DICOM organ dose does not accurately represent calculated dose in mammography

    NASA Astrophysics Data System (ADS)

    Suleiman, Moayyad E.; Brennan, Patrick C.; McEntee, Mark F.

    2016-03-01

    This study aims to analyze the agreement between the mean glandular dose estimated by the mammography unit (organ dose) and mean glandular dose calculated using Dance et al published method (calculated dose). Anonymised digital mammograms from 50 BreastScreen NSW centers were downloaded and exposure information required for the calculation of dose was extracted from the DICOM header along with the organ dose estimated by the system. Data from quality assurance annual tests for the included centers were collected and used to calculate the mean glandular dose for each mammogram. Bland-Altman analysis and a two-tailed paired t-test were used to study the agreement between calculated and organ dose and the significance of any differences. A total of 27,869 dose points from 40 centers were included in the study, mean calculated dose and mean organ dose (+/- standard deviation) were 1.47 (+/-0.66) and 1.38 (+/-0.56) mGy respectively. A statistically significant 0.09 mGy bias (t = 69.25; p<0.0001) with 95% limits of agreement between calculated and organ doses ranging from -0.34 and 0.52 were shown by Bland-Altman analysis, which indicates a small yet highly significant difference between the two means. The use of organ dose for dose audits is done at the risk of over or underestimating the calculated dose, hence, further work is needed to identify the causal agents for differences between organ and calculated doses and to generate a correction factor for organ dose.

  11. A minimum spanning forest based classification method for dedicated breast CT images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pike, Robert; Sechopoulos, Ioannis; Fei, Baowei, E-mail: bfei@emory.edu

    Purpose: To develop and test an automated algorithm to classify different types of tissue in dedicated breast CT images. Methods: Images of a single breast of five different patients were acquired with a dedicated breast CT clinical prototype. The breast CT images were processed by a multiscale bilateral filter to reduce noise while keeping edge information and were corrected to overcome cupping artifacts. As skin and glandular tissue have similar CT values on breast CT images, morphologic processing is used to identify the skin based on its position information. A support vector machine (SVM) is trained and the resulting modelmore » used to create a pixelwise classification map of fat and glandular tissue. By combining the results of the skin mask with the SVM results, the breast tissue is classified as skin, fat, and glandular tissue. This map is then used to identify markers for a minimum spanning forest that is grown to segment the image using spatial and intensity information. To evaluate the authors’ classification method, they use DICE overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on five patient images. Results: Comparison between the automatic and the manual segmentation shows that the minimum spanning forest based classification method was able to successfully classify dedicated breast CT image with average DICE ratios of 96.9%, 89.8%, and 89.5% for fat, glandular, and skin tissue, respectively. Conclusions: A 2D minimum spanning forest based classification method was proposed and evaluated for classifying the fat, skin, and glandular tissue in dedicated breast CT images. The classification method can be used for dense breast tissue quantification, radiation dose assessment, and other applications in breast imaging.« less

  12. Detectability comparison between a high energy x-ray phase sensitive and mammography systems in imaging phantoms with varying glandular-adipose ratios

    NASA Astrophysics Data System (ADS)

    Ghani, Muhammad U.; Wong, Molly D.; Wu, Di; Zheng, Bin; Fajardo, Laurie L.; Yan, Aimin; Fuh, Janis; Wu, Xizeng; Liu, Hong

    2017-05-01

    The objective of this study was to demonstrate the potential benefits of using high energy x-rays in comparison with the conventional mammography imaging systems for phase sensitive imaging of breast tissues with varying glandular-adipose ratios. This study employed two modular phantoms simulating the glandular (G) and adipose (A) breast tissue composition in 50 G-50 A and 70 G-30 A percentage densities. Each phantom had a thickness of 5 cm with a contrast detail test pattern embedded in the middle. For both phantoms, the phase contrast images were acquired using a micro-focus x-ray source operated at 120 kVp and 4.5 mAs, with a magnification factor (M) of 2.5 and a detector with a 50 µm pixel pitch. The mean glandular dose delivered to the 50 G-50 A and 70 G-30 A phantom sets were 1.33 and 1.3 mGy, respectively. A phase retrieval algorithm based on the phase attenuation duality that required only a single phase contrast image was applied. Conventional low energy mammography images were acquired using GE Senographe DS and Hologic Selenia systems utilizing their automatic exposure control (AEC) settings. In addition, the automatic contrast mode (CNT) was also used for the acquisition with the GE system. The AEC mode applied higher dose settings for the 70 G-30 A phantom set. As compared to the phase contrast images, the dose levels for the AEC mode acquired images were similar while the dose levels for the CNT mode were almost double. The observer study, contrast-to-noise ratio and figure of merit comparisons indicated a large improvement with the phase retrieved images in comparison to the AEC mode images acquired with the clinical systems for both density levels. As the glandular composition increased, the detectability of smaller discs decreased with the clinical systems, particularly with the GE system, even at higher dose settings. As compared to the CNT mode (double dose) images, the observer study also indicated that the phase retrieved images provided similar or improved detection for all disc sizes except for the disk diameters of 2 mm and 1 mm for the 50 G-50 A phantom and 3 mm and 0.5 mm for the 70 G-30 A phantom. This study demonstrated the potential of utilizing a high energy phase sensitive x-ray imaging system to improve lesion detection and reduce radiation dose when imaging breast tissues with varying glandular compositions.

  13. Design of a contrast-enhanced dual-energy tomosynthesis system for breast cancer imaging

    NASA Astrophysics Data System (ADS)

    Hörnig, M. D.; Bätz, L.; Mertelmeier, T.

    2012-03-01

    Digital breast tomosynthesis (DBT) is a three-dimensional X-ray imaging modality that has the potential to decrease the superimposition effect of breast structural noise, thereby increasing lesion conspicuity. To further improve breast cancer detection, our work has been devoted to develop a prototype for contrast-enhanced dual-energy tomosynthesis (CEDET). CEDET involves the injection of an iodinated contrast agent and measures the relative increase in uptake of contrast in the suspected breast cancer lesion. Either temporal or dual-energy subtraction techniques may be used to implement CEDET. Both 2D contrast-enhanced dual-energy mammography and 3D tomosynthesis can be applied. Here we present the design of a prototype CEDET system based on the Siemens MAMMOMAT Inspiration and employing two additional high-energy filters in addition to the standard Rh filter, the latter being used for the low-energy acquisitions. A quality factor of squared signal-difference-to-noise-ratio of iodine per pixel area and average glandular dose as a function of breast thickness is used to optimize the filter material, the filter thickness, and the tube voltage. The average glandular dose can be calculated from the entrance surface air kerma using computed conversion coefficients DgN for the used X-ray spectra. We also present the results of DQE measurements of the amorphous selenium detector involved. Finally, results of phantom tests for tomosynthesis acquisition and first clinical data in the 2D mode will be shown.

  14. Definition of Local Diagnostic Reference Levels in a Radiology Department Using a Dose Tracking Software.

    PubMed

    Ghetti, C; Ortenzia, O; Palleri, F; Sireus, M

    2017-06-01

    Dose optimization in radiological examinations is a mandatory issue: in this study local Diagnostic Reference Levels (lDRLs) for Clinical Mammography (MG), Computed Tomography (CT) and Interventional Cardiac Procedures (ICP) performed in our Radiology Department were established. Using a dose tracking software, we have collected Average Glandular Dose (AGD) for two clinical mammographic units; CTDIvol, Size-Specific Dose Estimate (SSDE), Dose Length Product (DLP) and total DLP (DLPtot) for five CT scanners; Fluoro Time, Fluoro Dose Area Product (DAP) and total DAP (DAPtot) for two angiographic systems. Data have been compared with Italian Regulation and with the recent literature. The 75th percentiles of the different dosimetric indices have been calculated. Automated methods of radiation dose data collection allow a fast and detailed analysis of a great amount of data and an easy determination of lDRLs for different radiological procedures. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Simulation of breast compression in mammography using finite element analysis: A preliminary study

    NASA Astrophysics Data System (ADS)

    Liu, Yan-Lin; Liu, Pei-Yuan; Huang, Mei-Lan; Hsu, Jui-Ting; Han, Ruo-Ping; Wu, Jay

    2017-11-01

    Adequate compression during mammography lowers the absorbed dose in the breast and improves the image quality. The compressed breast thickness (CBT) is affected by various factors, such as breast volume, glandularity, and compression force. In this study, we used the finite element analysis to simulate breast compression and deformation and validated the simulated CBT with clinical mammography results. Image data from ten subjects who had undergone mammography screening and breast magnetic resonance imaging (MRI) were collected, and their breast models were created according to the MR images. The non-linear tissue deformation under 10-16 daN in the cranial-caudal direction was simulated. When the clinical compression force was used, the simulated CBT ranged from 2.34 to 5.90 cm. The absolute difference between the simulated CBT and the clinically measured CBT ranged from 0.5 to 7.1 mm. The simulated CBT had a strong positive linear relationship to breast volume and a weak negative correlation to glandularity. The average simulated CBT under 10, 12, 14, and 16 daN was 5.68, 5.12, 4.67, and 4.25 cm, respectively. Through this study, the relationships between CBT, breast volume, glandularity, and compression force are provided for use in clinical mammography.

  16. Automated Breast Density Computation in Digital Mammography and Digital Breast Tomosynthesis: Influence on Mean Glandular Dose and BIRADS Density Categorization.

    PubMed

    Castillo-García, Maria; Chevalier, Margarita; Garayoa, Julia; Rodriguez-Ruiz, Alejandro; García-Pinto, Diego; Valverde, Julio

    2017-07-01

    The study aimed to compare the breast density estimates from two algorithms on full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) and to analyze the clinical implications. We selected 561 FFDM and DBT examinations from patients without breast pathologies. Two versions of a commercial software (Quantra 2D and Quantra 3D) calculated the volumetric breast density automatically in FFDM and DBT, respectively. Other parameters such as area breast density and total breast volume were evaluated. We compared the results from both algorithms using the Mann-Whitney U non-parametric test and the Spearman's rank coefficient for data correlation analysis. Mean glandular dose (MGD) was calculated following the methodology proposed by Dance et al. Measurements with both algorithms are well correlated (r ≥ 0.77). However, there are statistically significant differences between the medians (P < 0.05) of most parameters. The volumetric and area breast density median values from FFDM are, respectively, 8% and 77% higher than DBT estimations. Both algorithms classify 35% and 55% of breasts into BIRADS (Breast Imaging-Reporting and Data System) b and c categories, respectively. There are no significant differences between the MGD calculated using the breast density from each algorithm. DBT delivers higher MGD than FFDM, with a lower difference (5%) for breasts in the BIRADS d category. MGD is, on average, 6% higher than values obtained with the breast glandularity proposed by Dance et al. Breast density measurements from both algorithms lead to equivalent BIRADS classification and MGD values, hence showing no difference in clinical outcomes. The median MGD values of FFDM and DBT examinations are similar for dense breasts (BIRADS d category). Published by Elsevier Inc.

  17. Comparison of radiologist performance with photon-counting full-field digital mammography to conventional full-field digital mammography.

    PubMed

    Cole, Elodia B; Toledano, Alicia Y; Lundqvist, Mats; Pisano, Etta D

    2012-08-01

    The purpose of this study was to assess the performance of a MicroDose photon-counting full-field digital mammography (PCM) system in comparison to full-field digital mammography (FFDM) for area under the receiver-operating characteristic (ROC) curve (AUC), sensitivity, specificity, and feature analysis of standard-view mammography for women presenting for screening mammography, diagnostic mammography, or breast biopsy. A total of 133 women were enrolled in this study at two European medical centers, with 67 women who had a pre-existing 10-36 months FFDM enrolled prospectively into the study and 66 women who underwent breast biopsy and had screening PCM and diagnostic FFDM, including standard craniocaudal and mediolateral oblique views of the breast with the lesion, enrolled retrospectively. The case mix consisted of 49 cancers, 17 biopsy-benign cases, and 67 normal cases. Sixteen radiologists participated in the reader study and interpreted all 133 cases in both conditions, separated by washout period of ≥4 weeks. ROC curve and free-response ROC curve analyses were performed for noninferiority of PCM compared to FFDM using a noninferiority margin Δ value of 0.10. Feature analysis of the 66 cases with lesions was conducted with all 16 readers at the conclusion of the blinded reads. Mean glandular dose was recorded for all cases. The AUC for PCM was 0.947 (95% confidence interval [CI], 0.920-0.974) and for FFDM was 0.931 (95% CI, 0.898-0.964). Sensitivity per case for PCM was 0.936 (95% CI, 0.897-0.976) and for FFDM was 0.908 (95% CI, 0.856-0.960). Specificity per case for PCM was 0.764 (95% CI, 0.688-0.841) and for FFDM was 0.749 (95% CI, 0.668-0.830). Free-response ROC curve figures of merit were 0.920 (95% CI, 0.881-0.959) and 0.903 (95% CI, 0.858-0.948) for PCM and FFDM, respectively. Sensitivity per lesion was 0.903 (95% CI, 0.846-0.960) and 0.883 (95% CI, 0.823-0.944) for PCM and FFDM, respectively. The average false-positive marks per image of noncancer cases were 0.265 (95% CI, 0.171-0.359) and 0.281 (95% CI, 0.188-0.374) for PCM and FFDM, respectively. Noninferiority P values for AUC, sensitivity (per case and per lesion), specificity, and average false-positive marks per image were all statistically significant (P < .001). The noninferiority P value for free-response ROC was <.025, from the 95% CI for the difference. Feature analysis resulted in PCM being preferred to FFDM by the readers for ≥70% of the cases. The average mean glandular dose for PCM was 0.74 mGy (95% CI, 0.722-0.759 mGy) and for FFDM was 1.23 mGy (95% CI, 1.199-1.262 mGy). In this study, radiologist performance with PCM was not inferior to that with conventional FFDM at an average 40% lower mean glandular dose. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  18. Results of a 2011 national questionnaire for investigation of mean glandular dose from mammography in Japan.

    PubMed

    Asada, Y; Suzuki, S; Minami, K; Shirakawa, S

    2014-03-01

    Diagnostic reference levels (DRLs) for mammography have yet to be created in Japan. A national questionnaire investigation into radiographic conditions in Japan was carried out for the purpose of creating DRLs. Items investigated included the following: tube voltage; tube current; current-time product; source-image distance; craniocaudal view; automatic exposure control (AEC) settings; name of mammography unit; image receptor system (computed radiography (CR), flat panel detector (FPD), or film/screen (F/S)); and supported or unsupported monitor diagnosis (including monitor resolution). Estimation of the mean glandular dose (MGD) for mammography was performed and compared with previous investigations. The MGD was 1.58(0.48) mGy, which did not significantly differ from a 2007 investigation. In relation to image receptors, although no difference in average MGD values was observed between CR and FPD systems, F/S systems had a significantly decreased value compared to both CR and FPDs. Concerning digital systems (FPDs), the MGD value of the direct conversion system was significantly higher than the indirect conversion system. No significant difference in MGD value was evident concerning type of monitor diagnosis for either the CR or the FPD digital systems; however, hard copies were used more often in CR. No significant difference in the MGD value was found in relation to monitor resolution. This report suggests ways to lower the doses patients undergoing mammography receive in Japan, and serves as reference data for 4.2 cm compressed breast tissue of 50% composition DRLs. Furthermore, our findings suggest that further optimisation of FPD settings can promote a reduction in the MGD value.

  19. TU-F-18C-05: Evaluation of a Method to Calculate Patient-Oriented MGD Coefficients Using Estimates of Glandular Tissue Distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Porras-Chaverri, M; University of Costa Rica, San Jose; Galavis, P

    Purpose: Evaluate mammographic mean glandular dose (MGD) coefficients for particular known tissue distributions using a novel formalism that incorporates the effect of the heterogeneous glandular tissue distribution, by comparing them with MGD coefficients derived from the corresponding anthropomorphic computer breast phantom. Methods: MGD coefficients were obtained using MCNP5 simulations with the currently used homogeneous assumption and the heterogeneously-layered breast (HLB) geometry and compared against those from the computer phantom (ground truth). The tissue distribution for the HLB geometry was estimated using glandularity map image pairs corrected for the presence of non-glandular fibrous tissue. Heterogeneity of tissue distribution was quantified usingmore » the glandular tissue distribution index, Idist. The phantom had 5 cm compressed breast thickness (MLO and CC views) and 29% whole breast glandular percentage. Results: Differences as high as 116% were found between the MGD coefficients with the homogeneous breast core assumption and those from the corresponding ground truth. Higher differences were found for cases with more heterogeneous distribution of glandular tissue. The Idist for all cases was in the [−0.8{sup −}+0.3] range. The use of the methods presented in this work results in better agreement with ground truth with an improvement as high as 105 pp. The decrease in difference across all phantom cases was in the [9{sup −}105] pp range, dependent on the distribution of glandular tissue and was larger for the cases with the highest Idist values. Conclusion: Our results suggest that the use of corrected glandularity image pairs, as well as the HLB geometry, improves the estimates of MGD conversion coefficients by accounting for the distribution of glandular tissue within the breast. The accuracy of this approach with respect to ground truth is highly dependent on the particular glandular tissue distribution studied. Predrag Bakic discloses current funding from NIH, NSF, and DoD, former funding from Real Time Tomography, LLC and a current research collaboration with Barco and Hologic.« less

  20. Distribution of Absorbed Dose in Cone-Beam Breast Computed Tomography: A Phantom Study With Radiochromic Films

    NASA Astrophysics Data System (ADS)

    Russo, Paolo; Coppola, Teresa; Mettivier, Giovanni

    2010-08-01

    Cone-Beam Breast Computed Tomography (CBBCT) of the pendant breast with dedicated scanners is an experimental 3D X-ray imaging technique for breast cancer diagnosis under evaluation in comparison to conventional two-view 2-D mammography of the compressed breast. In CBBCT it is generally assumed that a more uniform distribution of the radiation dose to the breast volume can be obtained, with respect to mammography, at equal Mean Glandular Dose (MGD) levels. In fact, in CBBCT the X-ray beam rotates for 360 deg around the breast, while in each mammography view the breast is irradiated from one side only. Using a CBBCT laboratory scanner developed by our group, we have measured the distribution of the radiation dose in a hemi-ellipsoidal PMMA breast phantom of 14 cm diameter simulating the average uncompressed breast, using radiochromic films type XR-SP inserted at mid-plane in the phantom. The technique factors were 80 kVp (5.6 mm Al Half Value Layer), tube load in the range 23-100 mAs, for an air kerma at isocenter in the range 4.7-20 mGy, for a calculated MGD in the range 3.5-15 mGy for a 14 cm diameter breast of 50% glandularity. Results indicate that the dose decreases from the periphery to the center of the phantom, and that along a transverse profile, the relative dose variation Δ = ((edge-center)/center) is up to (25 ±4)% at a distance of 80 mm from the nipple. As for the relative dose variation along the phantom longitudinal axis, the maximum value at middle of the phantom measured is δ = ((nipple-chest wall)/chest wall) = -(15 ±4)%, indicating that the dose decreases from the chest wall toward the nipple. The values of the parameters Δ and δ depend also on the height of the X-ray tube focal spot with respect to the phantom vertex (nipple). Results are in rough agreement with similar previous determinations using thermoluminescence dosimeters.

  1. Dosimetric Comparison in Breast Radiotherapy of 4 MV and 6 MV on Physical Chest Simulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Donato da Silva, Sabrina; Passos Ribeiro Campos, Tarcisio; Batista Nogueira, Luciana

    2015-07-01

    According to the World Health Organization (2014) breast cancer is the main cause of death by cancer in women worldwide. The biggest challenge of radiotherapy in the treatment of cancer is to deposit the entire prescribed dose homogeneously in the breast, sparing the surrounding tissue. In this context, this paper aimed at evaluating and comparing internal dose distribution in the mammary gland based on experimental procedures submitted to two distinct energy spectra produced in breast cancer radiotherapy. The methodology consisted of reproducing opposite parallel fields used in the treatment of breast tumors in a chest phantom. This simulator with syntheticmore » breast, composed of equivalent tissue material (TE), was previously developed by the NRI Research Group (UFMG). The computer tomography (CT) scan of the simulator was obtained antecedently. The radiotherapy planning systems (TPS) in the chest phantom were performed in the ECLIPSE system from Varian Medical Systems and CAT 3D system from MEVIS. The irradiations were reproduced in the Varian linear accelerator, model SL- 20 Precise, 6 MV energy and Varian linear accelerator, 4 MV Clinac 6x SN11 model. Calibrations of the absorbed dose versus optical density from radiochromic films were generated in order to obtain experimental dosimetric distribution at the films positioned within the glandular and skin equivalent tissues of the chest phantom. The spatial dose distribution showed equivalence with the TPS on measurement data performed in the 6 MV spectrum. The average dose found in radiochromic films placed on the skin ranged from 49 to 79%, and from 39 to 49% in the mammary areola, for the prescribed dose. Dosimetric comparisons between the spectra of 4 and 6 MV, keeping the constant geometry of the fields applied in the same phantom, will be presented showing their equivalence in breast radiotherapy, as well as the variations will be discussed. To sum up, the dose distribution has reached the value expected in the breast dose of the 180 cGy in a wide range of the film in the glandular TE in both spectra. (authors)« less

  2. Development of low-dose photon-counting contrast-enhanced tomosynthesis with spectral imaging.

    PubMed

    Schmitzberger, Florian F; Fallenberg, Eva Maria; Lawaczeck, Rüdiger; Hemmendorff, Magnus; Moa, Elin; Danielsson, Mats; Bick, Ulrich; Diekmann, Susanne; Pöllinger, Alexander; Engelken, Florian J; Diekmann, Felix

    2011-05-01

    To demonstrate the feasibility of low-dose photon-counting tomosynthesis in combination with a contrast agent (contrast material-enhanced tomographic mammography) for the differentiation of breast cancer. All studies were approved by the institutional review board, and all patients provided written informed consent. A phantom model with wells of iodinated contrast material (3 mg of iodine per milliliter) 1, 2, 5, 10, and 15 mm in diameter was assessed. Nine patients with malignant lesions and one with a high-risk lesion (atypical papilloma) were included (all women; mean age, 60.7 years). A multislit photon-counting tomosynthesis system was utilized (spectral imaging) to produce both low- and high-energy tomographic data (below and above the k edge of iodine, respectively) in a single scan, which allowed for dual-energy visualization of iodine. Images were obtained prior to contrast material administration and 120 and 480 seconds after contrast material administration. Four readers independently assessed the images along with conventional mammograms, ultrasonographic images, and magnetic resonance images. Glandular dose was estimated. Contrast agent was visible in the phantom model with simulated spherical tumor diameters as small as 5 mm. The average glandular dose was measured as 0.42 mGy per complete spectral imaging tomosynthesis scan of one breast. Because there were three time points (prior to contrast medium administration and 120 and 480 seconds after contrast medium administration), this resulted in a total dose of 1.26 mGy for the whole procedure in the breast with the abnormality. Seven of 10 cases were categorized as Breast Imaging Reporting and Data System score of 4 or higher by all four readers when reviewing spectral images in combination with mammograms. One lesion near the chest wall was not captured on the spectral image because of a positioning problem. The use of contrast-enhanced tomographic mammography has been demonstrated successfully in patients with promising diagnostic benefit. Further studies are necessary to fully assess diagnostic sensitivity and specificity. RSNA, 2011

  3. Global characterization of Artemisia annua glandular trichome transcriptome using 454 pyrosequencing

    PubMed Central

    Wang, Wei; Wang, Yejun; Zhang, Qing; Qi, Yan; Guo, Dianjing

    2009-01-01

    Background Glandular trichomes produce a wide variety of commercially important secondary metabolites in many plant species. The most prominent anti-malarial drug artemisinin, a sesquiterpene lactone, is produced in glandular trichomes of Artemisia annua. However, only limited genomic information is currently available in this non-model plant species. Results We present a global characterization of A. annua glandular trichome transcriptome using 454 pyrosequencing. Sequencing runs using two normalized cDNA collections from glandular trichomes yielded 406,044 expressed sequence tags (average length = 210 nucleotides), which assembled into 42,678 contigs and 147,699 singletons. Performing a second sequencing run only increased the number of genes identified by ~30%, indicating that massively parallel pyrosequencing provides deep coverage of the A. annua trichome transcriptome. By BLAST search against the NCBI non-redundant protein database, putative functions were assigned to over 28,573 unigenes, including previously undescribed enzymes likely involved in sesquiterpene biosynthesis. Comparison with ESTs derived from trichome collections of other plant species revealed expressed genes in common functional categories across different plant species. RT-PCR analysis confirmed the expression of selected unigenes and novel transcripts in A. annua glandular trichomes. Conclusion The presence of contigs corresponding to enzymes for terpenoids and flavonoids biosynthesis suggests important metabolic activity in A. annua glandular trichomes. Our comprehensive survey of genes expressed in glandular trichome will facilitate new gene discovery and shed light on the regulatory mechanism of artemisinin metabolism and trichome function in A. annua. PMID:19818120

  4. Dosimetric implications of age related glandular changes in screening mammography

    NASA Astrophysics Data System (ADS)

    Beckett, J. R.; Kotre, C. J.

    2000-03-01

    The UK National Health Service Breast Screening Programme is currently organized to routinely screen women between the ages of 50 and 64, with screening for older women available on request. The lower end of this age range closely matches the median age for the menopause (51 years), during which significant changes in the composition of the breast are known to occur. In order to quantify the dosimetric effect of these changes, radiographic factors and compressed breast thickness data for a cohort of 1258 women aged between 35 and 79 undergoing breast screening mammography have been used to derive estimates of breast glandularity and mean glandular dose (MGD), and examine their variation with age. The variation of mean radiographic exposure factors with age is also investigated. The presence of a significant number of age trial women within the cohort allowed an extended age range to be studied. Estimates of MGD including corrections for breast glandularity based on compressed breast thickness only, compressed breast thickness and age and for each individual woman are compared with the MGD based on the conventional assumption of a 50:50 adipose/glandular composition. It has been found that the use of the conventional 50:50 assumption leads to overestimates of MGD of up to 13% over the age range considered. By using compressed breast thickness to estimate breast glandularity, this error range can be reduced to 8%, whilst age and compressed breast thickness based glandularity estimates result in an error range of 1%.

  5. Quantification of breast density with dual energy mammography: A simulation study

    PubMed Central

    Ducote, Justin L.; Molloi, Sabee

    2008-01-01

    Breast density, the percentage of glandular breast tissue, has been identified as an important yet underutilized risk factor in the development of breast cancer. A quantitative method to measure breast density with dual energy imaging was investigated using a computer simulation model. Two configurations to measure breast density were evaluated: the usage of monoenergetic beams and an ideal detector, and the usage of polyenergetic beams with spectra from a tungsten anode x-ray tube with a detector modeled after a digital mammography system. The simulation model calculated the mean glandular dose necessary to quantify the variability of breast density to within 1∕3%. The breast was modeled as a semicircle 10 cm in radius with equal homogenous thicknesses of adipose and glandular tissues. Breast thicknesses were considered in the range of 2–10 cm and energies in the range of 10–150 keV for the two monoenergetic beams, and 20–150 kVp for spectra with a tungsten anode x-ray tube. For a 4.2 cm breast thickness, the required mean glandular doses were 0.183 μGy for two monoenergetic beams at 19 and 71 keV, and 9.85 μGy for two polyenergetic spectra from a tungsten anode at 32 and 96 kVp with beam filtrations of 50 μm Rh and 300 μm Cu for the low and high energy beams, respectively. The results suggest that for either configuration, breast density can be precisely measured with dual energy imaging requiring only a small amount of additional dose to the breast. The possibility of using a standard screening mammogram as the low energy image is also discussed. PMID:19175100

  6. A breast-specific, negligible-dose scatter correction technique for dedicated cone-beam breast CT: a physics-based approach to improve Hounsfield Unit accuracy

    NASA Astrophysics Data System (ADS)

    Yang, Kai; Burkett, George, Jr.; Boone, John M.

    2014-11-01

    The purpose of this research was to develop a method to correct the cupping artifact caused from x-ray scattering and to achieve consistent Hounsfield Unit (HU) values of breast tissues for a dedicated breast CT (bCT) system. The use of a beam passing array (BPA) composed of parallel-holes has been previously proposed for scatter correction in various imaging applications. In this study, we first verified the efficacy and accuracy using BPA to measure the scatter signal on a cone-beam bCT system. A systematic scatter correction approach was then developed by modeling the scatter-to-primary ratio (SPR) in projection images acquired with and without BPA. To quantitatively evaluate the improved accuracy of HU values, different breast tissue-equivalent phantoms were scanned and radially averaged HU profiles through reconstructed planes were evaluated. The dependency of the correction method on object size and number of projections was studied. A simplified application of the proposed method on five clinical patient scans was performed to demonstrate efficacy. For the typical 10-18 cm breast diameters seen in the bCT application, the proposed method can effectively correct for the cupping artifact and reduce the variation of HU values of breast equivalent material from 150 to 40 HU. The measured HU values of 100% glandular tissue, 50/50 glandular/adipose tissue, and 100% adipose tissue were approximately 46, -35, and -94, respectively. It was found that only six BPA projections were necessary to accurately implement this method, and the additional dose requirement is less than 1% of the exam dose. The proposed method can effectively correct for the cupping artifact caused from x-ray scattering and retain consistent HU values of breast tissues.

  7. WE-DE-207B-11: Implementation of Size-Specific 3D Beam Modulation Filters On a Dedicated Breast CT Platform Using Breast Immobilization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hernandez, A; Boone, J

    Purpose: To implement a 3D beam modulation filter (3D-BMF) in dedicated breast CT (bCT) and develop a method for conforming the patient’s breast to a pre-defined shape, optimizing the effects of the filter. This work expands on previous work reporting the methodology for designing a 3D-BMF that can spare unnecessary dose and improve signal equalization at the detector by preferentially filtering the beam in the thinner anterior and peripheral breast regions. Methods: Effective diameter profiles were measured for 219 segmented bCT images, grouped into volume quintiles, and averaged within each group to represent the range of breast sizes found clinically.more » These profiles were then used to generate five size-specific computational phantoms and fabricate five size-specific UHMW phantoms. Each computational phantom was utilized for designing a size-specific 3D-BMF using previously reported methods. Glandular dose values and projection images were simulated in MCNP6 with and without the 3DBMF using the system specifications of our prototype bCT scanner “Doheny”. Lastly, thermoplastic was molded around each of the five phantom sizes and used to produce a series of breast immobilizers for use in conforming the patient’s breast during bCT acquisition. Results: After incorporating the 3D-BMF, MC simulations estimated an 80% average reduction in the detector dynamic range requirements across all phantom sizes. The glandular dose was reduced on average 57% after normalizing by the number of quanta reaching the detector under the thickest region of the breast. Conclusion: A series of bCT-derived breast phantoms were used to design size-specific 3D-BMFs and breast immobilizers that can be used on the bCT platform to conform the patient’s breast and therefore optimally exploit the benefits of the 3D-BMF. Current efforts are focused on fabricating several prototype 3D-BMFs and performing phantom scans on Doheny for MC simulation validation and image quality analysis. Research reported in this paper was supported in part by the National Cancer Institute of the National Institutes of Health under award R01CA181081. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institue of Health.« less

  8. Quantitative evaluation of glandular and stromal compartments in hyperplastic dog prostates: effect of 5-alpha reductase inhibitors.

    PubMed

    Laroque, P A; Prahalada, S; Molon-Noblot, S; Cohen, S M; Soper, K; Duprat, P; Peter, C P; van Zwieten, M J

    1995-09-01

    The objective of this study was to determine the effects of 2 different 5-alpha reductase inhibitors (finasteride and MK-0434) on the glandular and stromal compartments of hyperplastic canine prostates. In this study, dogs received 1 of the 2 compounds orally, at a dose of 1 mg/kg/day for 16 weeks; control dogs received a placebo. The morphological changes in the glandular and stromal compartments in the prostate were quantitated by a point-counting method on Masson's trichrome-stained sections. Treatment with 5-alpha reductase inhibitors resulted in significant (P < or = 0.05) decreases in mean prostatic volumes, microscopic evidence of prostatic atrophy, and significant (P < or = 0.05) decreases in the absolute volumes of the prostatic glandular and stromal compartments compared to controls. In finasteride-treated dogs, the mean percent change from baseline was: epithelium, -52; lumens, -58; fibrovascular stroma, -41; and smooth muscle, -29. In MK-0434-treated dogs, the mean percent change from baseline was: epithelium, -77; lumens, -58; fibrovascular stroma, -38; and smooth muscle, -42. The effect on the glandular compartment in dogs treated with MK-0434 was slightly greater than in dogs treated with finasteride; however, the effect on the stroma was similar. These results clearly demonstrate that inhibition of 5-alpha reductase enzyme activity affects growth and maintenance of both glandular and stromal compartments of dog hyperplastic prostates. It is likely that the decrease in size of the prostate in finasteride-treated (Proscar) men is due to shrinkage of both glandular and stromal compartments.

  9. Contrast-to-noise ratio in magnification mammography: a Monte Carlo study

    NASA Astrophysics Data System (ADS)

    Koutalonis, M.; Delis, H.; Spyrou, G.; Costaridou, L.; Tzanakos, G.; Panayiotakis, G.

    2007-06-01

    Magnification views are a common way to perform a secondary examination when suspicious abnormalities are found in a screening mammogram. The visibility of microcalcifications and breast lesions is restricted by the compromise between the image quality and the absorbed dose. In this study, image quality characteristics in magnification mammography were evaluated based on Monte Carlo techniques. A breast phantom was utilized, simulating a homogeneous mixture of adipose and glandular tissue in various percentages of glandularity, containing inhomogeneities of various sizes and compositions. The effect of the magnification degree, breast glandularity, tube voltage and anode/filter material combination on image quality characteristics was investigated in terms of a contrast-to-noise ratio (CNR). A performance index PIν was introduced in order to study the overall performance of various anode/filter combinations under different exposure parameters. Results demonstrate that CNR is improved with the degree of magnification and degraded as the breast glandularity is increased. Degree of magnification 1.3 offers the best overall performance for most of the anode/filter combinations utilized. Under magnification conditions, the role of dose is demoted against the image quality, as magnification views are secondary, diagnostic examinations and not screening procedures oriented to non-symptomatic women. For decreased image quality weighting, some anode/filter combinations different from Mo/0.030mmMo can be utilized as they offer a similar performance index. However, if the desired weighting for the image quality is high, the Mo/0.030mmMo combination has the best overall performance.

  10. TU-D-209-01: Dosimetry of Diagnostic Work Up Mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jallow, N; Sechopoulos, I

    2016-06-15

    Purpose: To investigate patient average glandular dose (AGD) characteristics of diagnostic mammography. Methods: The techniques used to image 14420 patients who received diagnostic work up mammography from October 2008 to December 2014 at one academic hospital were retrospectively collected. The most common diagnostic views and the techniques used for each according to compressed breast thickness were determined. For all techniques, 1st half value layer and air kerma output per tube current-exposure time product were measured; then the incident air kerma for each acquisition was calculated. The values for normalized glandular dose (DgN) were obtained with a validated Monte Carlo simulationmore » of mammographic acquisition. The mono-energetic DgN results were combined according to relative fluence using the TASMICS model to obtain DgN coefficients for each spectrum. The spectral DgN and calculated incident air kerma were used to estimate AGD of patients with breast thickness ranging from 2 to 8 cm. Results: The most common views utilized during diagnostic mammography were magnification craniocaudal (24%), magnification mediolateral (19%), spot craniocaudal (28%), and spot mediolateral oblique (24%). The AGD increased with increasing breast thickness for both the magnification and spot views. The AGD for a 5.5 cm thick breast was approximately 6.8 mGy and 2.2 mGy for the magnification and spot views, respectively. The AGD ranged from 3.6 mGy to 6.8 mGy for the magnification views and from 1.0 mGy to 3.1 mGy for spot views. The difference in AGD between the two magnification views or the two spot views was not significant. Conclusion: These results provide information on breast dose to which screening recalled women are exposed to. In addition to understanding the dose used for common clinical imaging tests, this data could be used when comparing use of mammography for diagnostic workup to other potential modalities, such as breast tomosynthesis and breast CT.« less

  11. Impact on dose and image quality of a software-based scatter correction in mammography.

    PubMed

    Monserrat, Teresa; Prieto, Elena; Barbés, Benigno; Pina, Luis; Elizalde, Arlette; Fernández, Belén

    2018-06-01

    Background In 2014, Siemens developed a new software-based scatter correction (Progressive Reconstruction Intelligently Minimizing Exposure [PRIME]), enabling grid-less digital mammography. Purpose To compare doses and image quality between PRIME (grid-less) and standard (with anti-scatter grid) modes. Material and Methods Contrast-to-noise ratio (CNR) was measured for various polymethylmethacrylate (PMMA) thicknesses and dose values provided by the mammograph were recorded. CDMAM phantom images were acquired for various PMMA thicknesses and inverse Image Quality Figure (IQF inv ) was calculated. Values of incident entrance surface air kerma (ESAK) and average glandular dose (AGD) were obtained from the DICOM header for a total of 1088 pairs of clinical cases. Two experienced radiologists compared subjectively the image quality of a total of 149 pairs of clinical cases. Results CNR values were higher and doses were lower in PRIME mode for all thicknesses. IQF inv values in PRIME mode were lower for all thicknesses except for 40 mm of PMMA equivalent, in which IQF inv was slightly greater in PRIME mode. A mean reduction of 10% in ESAK and 12% in AGD in PRIME mode with respect to standard mode was obtained. The clinical image quality in PRIME and standard acquisitions resulted to be similar in most of the cases (84% for the first radiologist and 67% for the second one). Conclusion The use of PRIME software reduces, in average, the dose of radiation to the breast without affecting image quality. This reduction is greater for thinner and denser breasts.

  12. SIMULATING LOCAL DENSE AREAS USING PMMA TO ASSESS AUTOMATIC EXPOSURE CONTROL IN DIGITAL MAMMOGRAPHY.

    PubMed

    Bouwman, R W; Binst, J; Dance, D R; Young, K C; Broeders, M J M; den Heeten, G J; Veldkamp, W J H; Bosmans, H; van Engen, R E

    2016-06-01

    Current digital mammography (DM) X-ray systems are equipped with advanced automatic exposure control (AEC) systems, which determine the exposure factors depending on breast composition. In the supplement of the European guidelines for quality assurance in breast cancer screening and diagnosis, a phantom-based test is included to evaluate the AEC response to local dense areas in terms of signal-to-noise ratio (SNR). This study evaluates the proposed test in terms of SNR and dose for four DM systems. The glandular fraction represented by the local dense area was assessed by analytic calculations. It was found that the proposed test simulates adipose to fully glandular breast compositions in attenuation. The doses associated with the phantoms were found to match well with the patient dose distribution. In conclusion, after some small adaptations, the test is valuable for the assessment of the AEC performance in terms of both SNR and dose. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Estimation of mean glandular dose for patients who undergo mammography and studying the factors affecting it

    NASA Astrophysics Data System (ADS)

    Barzanje, Sana L. N. H.; Harki, Edrees M. Tahir Nury

    2017-09-01

    The objective of this study was to determine mean glandular dose (MGD) during diagnostic mammography. This study was done in two hospitals in Hawler city in Kurdistan -region /Iraq, the exposure parameters kVp and mAs was recorded for 40 patients under go mammography. The MGD estimated by multiplied ESD with normalized glandular dose (Dn). The ESD measured indirectly by measuring output radiation mGy/mAs by using PalmRAD 907 as a suitable detector (Gigger detector).the results; shown that the mean and its standard deviation of MGD for Screen Film Mammography and Digital Mammography are (0.95±0.18)mGy and (0.99±0.26)mGy, respectively. And there is a significant difference between MGD for Screen Film Mammography and Digital Mammography views (p≤0. 05). Also the mean value and its standard deviation of MGD for screen film mammography is (0.96±0.21) for CC projection and (1.03±0.3) mGy for MLO projection, but mean value and its standard deviation evaluated of MGD for digital mammography is (0.92±0.17) mGy for CC projection and (0.98±0.2) mGy for MLO projection. As well as, the effect of kVp and mAs in MGD were studied, shows that in general as kVp and mAs increased the MGD increased accordingly in both of mammography systems.

  14. Enhancement of lymphocyte proliferation by mouse glandular kallikrein.

    PubMed

    Hu, Z Q; Murakami, K; Ikigai, H; Shimamura, T

    1992-03-01

    Mouse glandular kallikrein (mGK) strongly enhanced the spontaneous and mitogen-induced proliferation of lymphocytes. Both blast formation and 3H-TdR incorporation were dose-dependently enhanced at the same time many cells were killed. The enhancing activity was independent of EGF, because EGF-binding proteins (mGK-9 in mGK-6,9 mixture and mGK-13), renal kallikrein (mGK-6) and human kallikrein all displayed the same enhancement. A serine proteinase inhibitor, diisopropyl fluorophosphate, could block the enhancement by mGK. The new function suggests that mGK is important in the immune system as a regulatory molecule.

  15. The effect of dose heterogeneity on radiation risk in medical imaging.

    PubMed

    Samei, Ehsan; Li, Xiang; Chen, Baiyu; Reiman, Robert

    2013-06-01

    The current estimations of risk associated with medical imaging procedures rely on assessing the organ dose via direct measurements or simulation. The dose to each organ is assumed to be homogeneous. To take into account the differences in radiation sensitivities, the mean organ doses are weighted by a corresponding tissue-weighting coefficients provided by ICRP to calculate the effective dose, which has been used as a surrogate of radiation risk. However, those coefficients were derived under the assumption of a homogeneous dose distribution within each organ. That assumption is significantly violated in most medical-imaging procedures. In helical chest CT, for example, superficial organs (e.g. breasts) demonstrate a heterogeneous dose distribution, whereas organs on the peripheries of the irradiation field (e.g. liver) might possess a discontinuous dose profile. Projection radiography and mammography involve an even higher level of organ dose heterogeneity spanning up to two orders of magnitude. As such, mean dose or point measured dose values do not reflect the maximum energy deposited per unit volume of the organ. In this paper, the magnitude of the dose heterogeneity in both CT and projection X-ray imaging was reported, using Monte Carlo methods. The lung dose demonstrated factors of 1.7 and 2.2 difference between the mean and maximum dose for chest CT and radiography, respectively. The corresponding values for the liver were 1.9 and 3.5. For mammography and breast tomosynthesis, the difference between mean glandular dose and maximum glandular dose was 3.1. Risk models based on the mean dose were found to provide a reasonable reflection of cancer risk. However, for leukaemia, they were found to significantly under-represent the risk when the organ dose distribution is heterogeneous. A systematic study is needed to develop a risk model for heterogeneous dose distributions.

  16. Radiation doses in volume-of-interest breast computed tomography—A Monte Carlo simulation study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lai, Chao-Jen, E-mail: cjlai3711@gmail.com; Zhong, Yuncheng; Yi, Ying

    2015-06-15

    Purpose: Cone beam breast computed tomography (breast CT) with true three-dimensional, nearly isotropic spatial resolution has been developed and investigated over the past decade to overcome the problem of lesions overlapping with breast anatomical structures on two-dimensional mammographic images. However, the ability of breast CT to detect small objects, such as tissue structure edges and small calcifications, is limited. To resolve this problem, the authors proposed and developed a volume-of-interest (VOI) breast CT technique to image a small VOI using a higher radiation dose to improve that region’s visibility. In this study, the authors performed Monte Carlo simulations to estimatemore » average breast dose and average glandular dose (AGD) for the VOI breast CT technique. Methods: Electron–Gamma-Shower system code-based Monte Carlo codes were used to simulate breast CT. The Monte Carlo codes estimated were validated using physical measurements of air kerma ratios and point doses in phantoms with an ion chamber and optically stimulated luminescence dosimeters. The validated full cone x-ray source was then collimated to simulate half cone beam x-rays to image digital pendant-geometry, hemi-ellipsoidal, homogeneous breast phantoms and to estimate breast doses with full field scans. 13-cm in diameter, 10-cm long hemi-ellipsoidal homogeneous phantoms were used to simulate median breasts. Breast compositions of 25% and 50% volumetric glandular fractions (VGFs) were used to investigate the influence on breast dose. The simulated half cone beam x-rays were then collimated to a narrow x-ray beam with an area of 2.5 × 2.5 cm{sup 2} field of view at the isocenter plane and to perform VOI field scans. The Monte Carlo results for the full field scans and the VOI field scans were then used to estimate the AGD for the VOI breast CT technique. Results: The ratios of air kerma ratios and dose measurement results from the Monte Carlo simulation to those from the physical measurements were 0.97 ± 0.03 and 1.10 ± 0.13, respectively, indicating that the accuracy of the Monte Carlo simulation was adequate. The normalized AGD with VOI field scans was substantially reduced by a factor of about 2 over the VOI region and by a factor of 18 over the entire breast for both 25% and 50% VGF simulated breasts compared with the normalized AGD with full field scans. The normalized AGD for the VOI breast CT technique can be kept the same as or lower than that for a full field scan with the exposure level for the VOI field scan increased by a factor of as much as 12. Conclusions: The authors’ Monte Carlo estimates of normalized AGDs for the VOI breast CT technique show that this technique can be used to markedly increase the dose to the breast and thus the visibility of the VOI region without increasing the dose to the breast. The results of this investigation should be helpful for those interested in using VOI breast CT technique to image small calcifications with dose concern.« less

  17. Radiation doses in volume-of-interest breast computed tomography—A Monte Carlo simulation study

    PubMed Central

    Lai, Chao-Jen; Zhong, Yuncheng; Yi, Ying; Wang, Tianpeng; Shaw, Chris C.

    2015-01-01

    Purpose: Cone beam breast computed tomography (breast CT) with true three-dimensional, nearly isotropic spatial resolution has been developed and investigated over the past decade to overcome the problem of lesions overlapping with breast anatomical structures on two-dimensional mammographic images. However, the ability of breast CT to detect small objects, such as tissue structure edges and small calcifications, is limited. To resolve this problem, the authors proposed and developed a volume-of-interest (VOI) breast CT technique to image a small VOI using a higher radiation dose to improve that region’s visibility. In this study, the authors performed Monte Carlo simulations to estimate average breast dose and average glandular dose (AGD) for the VOI breast CT technique. Methods: Electron–Gamma-Shower system code-based Monte Carlo codes were used to simulate breast CT. The Monte Carlo codes estimated were validated using physical measurements of air kerma ratios and point doses in phantoms with an ion chamber and optically stimulated luminescence dosimeters. The validated full cone x-ray source was then collimated to simulate half cone beam x-rays to image digital pendant-geometry, hemi-ellipsoidal, homogeneous breast phantoms and to estimate breast doses with full field scans. 13-cm in diameter, 10-cm long hemi-ellipsoidal homogeneous phantoms were used to simulate median breasts. Breast compositions of 25% and 50% volumetric glandular fractions (VGFs) were used to investigate the influence on breast dose. The simulated half cone beam x-rays were then collimated to a narrow x-ray beam with an area of 2.5 × 2.5 cm2 field of view at the isocenter plane and to perform VOI field scans. The Monte Carlo results for the full field scans and the VOI field scans were then used to estimate the AGD for the VOI breast CT technique. Results: The ratios of air kerma ratios and dose measurement results from the Monte Carlo simulation to those from the physical measurements were 0.97 ± 0.03 and 1.10 ± 0.13, respectively, indicating that the accuracy of the Monte Carlo simulation was adequate. The normalized AGD with VOI field scans was substantially reduced by a factor of about 2 over the VOI region and by a factor of 18 over the entire breast for both 25% and 50% VGF simulated breasts compared with the normalized AGD with full field scans. The normalized AGD for the VOI breast CT technique can be kept the same as or lower than that for a full field scan with the exposure level for the VOI field scan increased by a factor of as much as 12. Conclusions: The authors’ Monte Carlo estimates of normalized AGDs for the VOI breast CT technique show that this technique can be used to markedly increase the dose to the breast and thus the visibility of the VOI region without increasing the dose to the breast. The results of this investigation should be helpful for those interested in using VOI breast CT technique to image small calcifications with dose concern. PMID:26127058

  18. Evaluation of the in vivo genotoxicity of Allura Red AC (Food Red No. 40).

    PubMed

    Honma, Masamitsu

    2015-10-01

    Allura Red AC (Food Red No. 40) is a red azo dye that is used for food coloring in beverage and confectionary products. However, its genotoxic properties remain controversial. To clarify the in vivo genotoxicity, we treated mice with Allura Red AC and investigated the induction of DNA damage (liver, glandular stomach), clastogenicity/anuegenicity (bone marrow), and mutagenicity (liver, glandular stomach) using Comet assays, micronucleus tests, and transgenic gene mutation assays, respectively. All studies were conducted in accordance with the Organization for Economic Co-operation and Development (OECD) guideline. Although Allura Red AC was administered up to the maximum doses recommended by the OECD guideline, no genotoxic effect was observed in any of the genotoxic endpoints. These data clearly show no evidence of in vivo genotoxic potential of Allura Red AC administered up to the maximum doses in mice. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Estimation of mean glandular dose for contrast enhanced digital mammography: factors for use with the UK, European and IAEA breast dosimetry protocols

    NASA Astrophysics Data System (ADS)

    Dance, D. R.; Young, K. C.

    2014-05-01

    The UK, European and IAEA protocols for breast dosimetry in mammography use tabulations of conversion factors, which relate measurements of incident air kerma to the mean glandular dose to the breast. To supplement the existing tabulations, a Monte Carlo computer program has been used to calculate conversion factors for the high-energy spectra used for contrast enhanced digital mammography. The calculations were made for the x-ray spectra from a tungsten target (tube voltage range 40-50 kV) filtered by 0.28, 0.30 and 0.32 mm of copper, and from molybdenum and rhodium targets (tube voltage range 40-49 kV), each filtered by 0.30 mm of copper. The g-factors for all of these spectra were plotted for each breast thickness as a function of half value layer (HVL) and were found to lie on smooth curves within 0.3%. These reflect the fact that the characteristic x-rays present in the spectra from molybdenum and rhodium are heavily filtered and all the spectra are essentially Bremsstrahlung. As a consequence, the s-factor previously used in the dosimetry protocols to adjust for different target/filter combinations can be taken as unity for all of the spectra considered. Tables of g-factors and c-factors are provided for breast thicknesses in the range 20-110 mm and HVLs in the range 2.4-3.6 mm of aluminium. The tables of c-factors are given for breast glandularities in the range 0.1%-100% and for typical glandularities for women in the age bands 40-49 and 50-64 attending the UK national breast screening programme.

  20. Quality assurance in mammography: College of Radiology Survey in Malaysia.

    PubMed

    Ho, E L M; Ng, K H; Wong, J H D; Wang, H B

    2006-06-01

    Malaysia's mammography QA practice was surveyed based on the Malaysian Ministry of Health and the American College of Radiology (ACR) requirements. Data on mammography unit, processor, image receptor, exposure factors, mean glandular dose (MGD), sensitometry, image quality and viewbox luminance were obtained. Mean developer temperature and cycle time were 34.1 +/- 1.8degreesC and 107.7 +/- 33.2 seconds. Mean base+fog level, speed index and contrast index were 0.20+/-0.01, 1.20+/-0.01 and 1.33+/-0.26 respectively. Eighty-six percent of the fifty centres passed the image quality test while 12.5% complied with ACR recommended viewbox luminance. Average MGD was 1.0+/-0.4 mGy. Malaysia is on the right track for QA but with room for total quality improvement.

  1. Si-Accumulation In Artemisia annua Glandular Trichomes Increases Artemisinin Concentration, but Does Not Interfere In the Impairment of Toxoplasma gondii Growth

    PubMed Central

    Rostkowska, Cristina; Mota, Caroline M.; Oliveira, Taísa C.; Santiago, Fernanda M.; Oliveira, Lilian A.; Korndörfer, Gaspar H.; Lana, Regina M. Q.; Rossi, Monica L.; Nogueira, Neusa L.; Simonnet, Xavier; Mineo, Tiago W. P.; Silva, Deise A.O.; Mineo, José R.

    2016-01-01

    Artemisia annua is used as a source of artemisinin, a potent therapeutic agent used for the treatment of infectious diseases, chiefly malaria. However, the low concentration (from 0.01 to 1.4% of dried leaf matter) of artemisinin in the plant obtained with the traditional cropping system makes it a relatively expensive drug, especially in developing countries. Considering that artemisinin and silicon (Si) are both stored in A. annua glandular trichomes, and that Si accumulation has never been investigated, this study aimed to look into Si effects on A. annua trichome artemisinin concentration, and whether leaf infusion from Si-treated A. annua plants is able to control Toxoplasma gondii growth. T. gondii is the etiologic agent of toxoplasmosis, a zoonotic parasitic disease whose traditional treatment shows significant side effects. The experimental design consisted of A. annua seedlings randomly planted in soil treated with different doses of calcium/magnesium silicate (0, 200, 400, 800, and 1600 kg ha-1). Analysis of foliar macronutrients showed significant increases of nitrogen content only at the highest dose of silicate. Foliar micronutrients, Si concentrations, and plant height were not affected by any of the silicate doses. However, the dose of 400 kg ha-1 of silicate increased the trichome size, which in turn raised artemisinin concentration in leaves and the infusion. In contrast, the 800 and 1600 kg ha-1 doses dramatically decreased artemisinin concentration. HeLa cell treatment with the infusion of A. annua grown in soil treated with 400 kg ha-1 of silicate decreased parasite proliferation in a dose-dependent manner when the treatment was carried out after or along with T. gondii infection. However, this effect was similar to A. annua grown in soil without silicate treatment. Thus, it can be concluded that, even though Si applied to the soil at 400 kg ha-1 has a positive effect on the A. annua glandular trichome size and the artemisinin concentration, this outcome cannot be directly associated with the efficiency of A. annua infusion on T. gondii growth, suggesting that other components from A. annua leaves could be acting in synergy with artemisinin. PMID:27721819

  2. Dose assessment in contrast enhanced digital mammography using simple phantoms simulating standard model breasts.

    PubMed

    Bouwman, R W; van Engen, R E; Young, K C; Veldkamp, W J H; Dance, D R

    2015-01-07

    Slabs of polymethyl methacrylate (PMMA) or a combination of PMMA and polyethylene (PE) slabs are used to simulate standard model breasts for the evaluation of the average glandular dose (AGD) in digital mammography (DM) and digital breast tomosynthesis (DBT). These phantoms are optimized for the energy spectra used in DM and DBT, which normally have a lower average energy than used in contrast enhanced digital mammography (CEDM). In this study we have investigated whether these phantoms can be used for the evaluation of AGD with the high energy x-ray spectra used in CEDM. For this purpose the calculated values of the incident air kerma for dosimetry phantoms and standard model breasts were compared in a zero degree projection with the use of an anti scatter grid. It was found that the difference in incident air kerma compared to standard model breasts ranges between -10% to +4% for PMMA slabs and between 6% and 15% for PMMA-PE slabs. The estimated systematic error in the measured AGD for both sets of phantoms were considered to be sufficiently small for the evaluation of AGD in quality control procedures for CEDM. However, the systematic error can be substantial if AGD values from different phantoms are compared.

  3. [Evaluation of the effectiveness of antibacterial substances in treating an experimental form of bubonic plague in monkeys].

    PubMed

    Romanov, V E; Evstigneev, V I; Vasil'ev, N T; Shabalin, B A; Paramonov, V E

    2001-01-01

    The modelling of glandular plague and selection of the conditions for estimating the efficacy of new antibacterials for the treatment of the infection were performed on hamadryads (baboons). The experiments showed that the average LD50 of the culture of a highly virulent strain of Yersinia pestis on its subcutaneous administration to the animals was 2089 viable microbes. In 18 per cent of the episodes the experimental glandular plague in the animals was complicated by secondary plague pneumonia. Subcutaneous administration of 2 x 10(7) viable microbial cell of the plague pathogen caused acute sepsis and the animal death. The treatment of the experimental glandular plague in the hamadryads demonstrated that new antibacterials such as amikacin, netilmicin, ceftriaxone, cefotaxime, ceftizoxime, doxycycline, rifampicin, ofloxacin and ciprofloxacin were not inferior in their efficacy to streptomycin and tetracycline successfully used in the therapy of patients with plague.

  4. Histotripsy of the Prostate for the Treatment of BPH: Chronic Results From a Canine Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, Timothy L.; Hempel, Chris R.; Lake, Alison M.

    2009-04-14

    Histotripsy was evaluated as a non-invasive BPH treatment. The prostates of 21 canine subjects were targeted with one of three histotripsy doses. Prostates were harvested immediately, 7 days, or 28 days after treatment and assessed for changes. Lower treatment doses were found to produced scattered cellular disruption and hemorrhage that was sometimes reversible. Higher doses perforated the urethra and produced cavities in the glandular prostate that healed to leave an enlarged urinary channel.

  5. Histotripsy of the Prostate for the Treatment of BPH: Chronic Results From a Canine Model

    NASA Astrophysics Data System (ADS)

    Hall, Timothy L.; Hempel, Chris R.; Lake, Alison M.; Kieran, Kathy; Ives, Kim; Fowlkes, J. Brian; Cain, Charles A.; Roberts, William W.

    2009-04-01

    Histotripsy was evaluated as a non-invasive BPH treatment. The prostates of 21 canine subjects were targeted with one of three histotripsy doses. Prostates were harvested immediately, 7 days, or 28 days after treatment and assessed for changes. Lower treatment doses were found to produced scattered cellular disruption and hemorrhage that was sometimes reversible. Higher doses perforated the urethra and produced cavities in the glandular prostate that healed to leave an enlarged urinary channel.

  6. Optimization of contrast-enhanced spectral mammography depending on clinical indication

    PubMed Central

    Dromain, Clarisse; Canale, Sandra; Saab-Puong, Sylvie; Carton, Ann-Katherine; Muller, Serge; Fallenberg, Eva Maria

    2014-01-01

    Abstract. The objective is to optimize low-energy (LE) and high-energy (HE) exposure parameters of contrast-enhanced spectral mammography (CESM) examinations in four different clinical applications for which different levels of average glandular dose (AGD) and ratios between LE and total doses are required. The optimization was performed on a Senographe DS with a SenoBright® upgrade. Simulations were performed to find the optima by maximizing the contrast-to-noise ratio (CNR) on the recombined CESM image using different targeted doses and LE image quality. The linearity between iodine concentration and CNR as well as the minimal detectable iodine concentration was assessed. The image quality of the LE image was assessed on the CDMAM contrast-detail phantom. Experiments confirmed the optima found on simulation. The CNR was higher for each clinical indication than for SenoBright®, including the screening indication for which the total AGD was 22% lower. Minimal iodine concentrations detectable in the case of a 3-mm-diameter round tumor were 12.5% lower than those obtained for the same dose in the clinical routine. LE image quality satisfied EUREF acceptable limits for threshold contrast. This newly optimized set of acquisition parameters allows increased contrast detectability compared to parameters currently used without a significant loss in LE image quality. PMID:26158058

  7. Optimization of contrast-enhanced spectral mammography depending on clinical indication.

    PubMed

    Dromain, Clarisse; Canale, Sandra; Saab-Puong, Sylvie; Carton, Ann-Katherine; Muller, Serge; Fallenberg, Eva Maria

    2014-10-01

    The objective is to optimize low-energy (LE) and high-energy (HE) exposure parameters of contrast-enhanced spectral mammography (CESM) examinations in four different clinical applications for which different levels of average glandular dose (AGD) and ratios between LE and total doses are required. The optimization was performed on a Senographe DS with a SenoBright® upgrade. Simulations were performed to find the optima by maximizing the contrast-to-noise ratio (CNR) on the recombined CESM image using different targeted doses and LE image quality. The linearity between iodine concentration and CNR as well as the minimal detectable iodine concentration was assessed. The image quality of the LE image was assessed on the CDMAM contrast-detail phantom. Experiments confirmed the optima found on simulation. The CNR was higher for each clinical indication than for SenoBright®, including the screening indication for which the total AGD was 22% lower. Minimal iodine concentrations detectable in the case of a 3-mm-diameter round tumor were 12.5% lower than those obtained for the same dose in the clinical routine. LE image quality satisfied EUREF acceptable limits for threshold contrast. This newly optimized set of acquisition parameters allows increased contrast detectability compared to parameters currently used without a significant loss in LE image quality.

  8. Potential of phase contrast x-ray imaging for detecting tumors in dense breast: initial phantom studies

    NASA Astrophysics Data System (ADS)

    Omoumi, Farid H.; Wu, Di; Guo, Yuran; Ghani, Muhammad U.; Li, Yuhua; Boyce, Kari E.; Liu, Hong

    2018-02-01

    The objective of this study is to demonstrate the potential of using the High-energy in-line phase contrast x-ray imaging to detect lesions that are indistinguishable by conventional x-ray mammography but are detectable by supplemental ultrasound screening within dense breasts. For this study, a custom-made prototype x-ray/ultrasound dualmodality phantom that mimics dense breast is created to include embedded carbon fiber disks with multiple diameters and thicknesses. The phase contrast image is acquired using a prototype at 120kVp, 67μA, exposure time of 16.7sec and focal spot size of 18.3μm with average glandular dose (AGD) of 0.3mGy under a geometric magnification of 2.48. The conventional x-ray image is acquired with a bench top system operating at 40kVp, 300μA, exposure time of 50sec and same AGD. The results demonstrate that conventional x-ray imaging is unable to detect any of the carbon fiber disks, while phase contrast imaging and ultrasonography are able to detect most or all of the disks under the applied experimental conditions. These results illustrate phase contrast imaging is capable of detecting targets in a dual-modality phantom which simulates lesions in dense breast tissue, when the simulated lesions are not distinguishable by conventional mammography. Therefore mammographic screening with phase contrast technique could eventually replace both x-ray and ultrasonography for screening detection of small lesions with microcalcification in dense breasts where pathologic lesions are masked due to highly glandular tissue. These results encourage further investigation using high glandular density phantoms to further evaluate the effectiveness of phase contrast imaging as a single modality test, which combines the advantages of both x-ray and ultrasound imaging in cancer screening of patients with dense breasts.

  9. The membrane-stabilizing action of zinc carnosine (Z-103) in stress-induced gastric ulceration in rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cho, C.H.; Luk, C.T.; Ogle, C.W.

    1991-01-01

    Zinc compounds have been shown to antagonize various types of gastric ulceration in rats. Zinc carnosine (Z-103), a newly developed agent was, therefore, examined for its antiulcer effect in stress-induced ulceration and also its membrane stabilizing action in rat stomachs. Cold-restraint stress induced severe hemorrhagic lesions together with increased mast cell degranulation and {beta}-glucuronidase release in the gastric glandular mucosa. A-103 pretreatment with a single oral dose reversed these actions in a dose-dependent manner. When the compound was incubated in concentrations of 10{sup {minus}7}, 10{sup {minus}6}, 10{sup {minus}5} or 10{sup {minus}4} M, with isolated hepatic lysosomes, it significantly reduced themore » spontaneous release of {beta}-glucuronidase in the medium. The present study not only demonstrates the antiulcer effect of Z-103 but also indicates that the protective action is likely to be mediated by its membrane-stabilizing action on mast cells and lysosomes in the gastric glandular mucosa.« less

  10. Dual-energy approach to contrast-enhanced mammography using the balanced filter method: spectral optimization and preliminary phantom measurement.

    PubMed

    Saito, Masatoshi

    2007-11-01

    Dual-energy contrast agent-enhanced mammography is a technique of demonstrating breast cancers obscured by a cluttered background resulting from the contrast between soft tissues in the breast. The technique has usually been implemented by exploiting two exposures to different x-ray tube voltages. In this article, another dual-energy approach using the balanced filter method without switching the tube voltages is described. For the spectral optimization of dual-energy mammography using the balanced filters, we applied a theoretical framework reported by Lemacks et al. [Med. Phys. 29, 1739-1751 (2002)] to calculate the signal-to-noise ratio (SNR) in an iodinated contrast agent subtraction image. This permits the selection of beam parameters such as tube voltage and balanced filter material, and the optimization of the latter's thickness with respect to some critical quantity-in this case, mean glandular dose. For an imaging system with a 0.1 mm thick CsI:T1 scintillator, we predict that the optimal tube voltage would be 45 kVp for a tungsten anode using zirconium, iodine, and neodymium balanced filters. A mean glandular dose of 1.0 mGy is required to obtain an SNR of 5 in order to detect 1.0 mg/cm2 iodine in the resulting clutter-free image of a 5 cm thick breast composed of 50% adipose and 50% glandular tissue. In addition to spectral optimization, we carried out phantom measurements to demonstrate the present dual-energy approach for obtaining a clutter-free image, which preferentially shows iodine, of a breast phantom comprising three major components-acrylic spheres, olive oil, and an iodinated contrast agent. The detection of iodine details on the cluttered background originating from the contrast between acrylic spheres and olive oil is analogous to the task of distinguishing contrast agents in a mixture of glandular and adipose tissues.

  11. Personalized estimates of radiation dose from dedicated breast CT in a diagnostic population and comparison with diagnostic mammography

    PubMed Central

    Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew; O’Connell, Avice M.; Conover, David L.

    2013-01-01

    This study retrospectively analyzed the mean glandular dose (MGD) to 133 breasts from 132 subjects, all women, who participated in a clinical trial evaluating dedicated breast CT in a diagnostic population. The clinical trial was conducted in adherence to a protocol approved by institutional review boards and the study participants provided written informed consent. Individual estimates of mean glandular dose to each breast from dedicated breast CT was obtained by combining x-ray beam characteristics with estimates of breast dimensions and fibroglandular fraction from volumetric breast CT images, and using normalized glandular dose coefficients. For each study participant and for the breast corresponding to that imaged with breast CT, an estimate of the MGD from diagnostic mammography (including supplemental views) was obtained from the DICOM image headers for comparison. This estimate uses normalized glandular dose coefficients corresponding to a breast with 50% fibroglandular weight fraction. The median fibroglandular weight fraction for the study cohort determined from volumetric breast CT images was 15%. Hence, the MGD from diagnostic mammography was corrected to be representative of the study cohort. Individualized estimates of MGD from breast CT ranged from 5.7 mGy to 27.8 mGy. Corresponding to the breasts imaged with breast CT, the MGD from diagnostic mammography ranged from 2.6 to 31.6 mGy. The mean (± inter-breast SD) and the median MGD (mGy) from dedicated breast CT exam were 13.9±4.6 and 12.6, respectively. For the corresponding breasts, the mean (± inter-breast SD) and the median MGD (mGy) from diagnostic mammography were 12.4±6.3 and 11.1, respectively. Statistical analysis indicated that at the 0.05 level, the distributions of MGD from dedicated breast CT and diagnostic mammography were significantly different (Wilcoxon signed ranks test, p = 0.007). While the interquartile range and the range (maximum-minimum) of MGD from dedicated breast CT was lower than diagnostic mammography, the median MGD from dedicated breast CT was approximately 13.5% higher than that from diagnostic mammography. The MGD for breast CT is based on a 1.45 mm skin layer and that for diagnostic mammography is based on a 4 mm skin layer; thus, favoring a lower estimate for MGD from diagnostic mammography. The median MGD from dedicated breast CT corresponds to the median MGD from 4 to 5 diagnostic mammography views. In comparison, for the same 133 breasts, the mean and the median number of views per breast during diagnostic mammography were 4.53 and 4, respectively. Paired analysis showed that there was approximately equal likelihood of receiving lower MGD from either breast CT or diagnostic mammography. Future work will investigate methods to reduce and optimize radiation dose from dedicated breast CT. PMID:24165162

  12. Dedicated breast CT: Fibroglandular volume measurements in a diagnostic population

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vedantham, Srinivasan; Shi Linxi; Karellas, Andrew

    2012-12-15

    Purpose: To determine the mean and range of volumetric glandular fraction (VGF) of the breast in a diagnostic population using a high-resolution flat-panel cone-beam dedicated breast CT system. This information is important for Monte Carlo-based estimation of normalized glandular dose coefficients and for investigating the dependence of VGF on breast dimensions, race, and pathology. Methods: Image data from a clinical trial investigating the role of dedicated breast CT that enrolled 150 women were retrospectively analyzed to determine the VGF. The study was conducted in adherence to a protocol approved by the institutional human subjects review boards and written informed consentmore » was obtained from all study participants. All participants in the study were assigned BI-RADS{sup Registered-Sign} 4 or 5 as per the American College of Radiology assessment categories after standard diagnostic work-up and underwent dedicated breast CT exam prior to biopsy. A Gaussian-kernel based fuzzy c-means algorithm was used to partition the breast CT images into adipose and fibroglandular tissue after segmenting the skin. Upon determination of the accuracy of the algorithm with a phantom, it was applied to 137 breast CT volumes from 136 women. VGF was determined for each breast and the mean and range were determined. Pathology results with classification as benign, malignant, and hyperplasia were available for 132 women, and were used to investigate if the distributions of VGF varied with pathology. Results: The algorithm was accurate to within {+-}1.9% in determining the volume of an irregular shaped phantom. The study mean ({+-} inter-breast SD) for the VGF was 0.172 {+-} 0.142 (range: 0.012-0.719). VGF was found to be negatively correlated with age, breast dimensions (chest-wall to nipple length, pectoralis to nipple length, and effective diameter at chest-wall), and total breast volume, and positively correlated with fibroglandular volume. Based on pathology, pairwise statistical analysis (Mann-Whitney test) indicated that at the 0.05 significance level, there was no significant difference in distributions of VGF without adjustment for age between malignant and nonmalignant breasts (p= 0.41). Pairwise comparisons of the distributions of VGF in increasing order of mammographic breast density indicated all comparisons were statistically significant (p < 0.002). Conclusions: This study used a different clinical prototype breast CT system than that in previous studies to image subjects from a different geographical region, and used a different algorithm for analysis of image data. The mean VGF estimated from this study is within the range reported in previous studies, indicating that the choice of 50% glandular weight fraction to represent an average breast for Monte Carlo-based estimation of normalized glandular dose coefficients in mammography needs revising. In the study, the distributions of VGF did not differ significantly with pathology.« less

  13. Orange Peel Excision of Gland: A Novel Surgical Technique for Treatment of Gynecomastia.

    PubMed

    S S, Shirol

    2016-12-01

    Gynecomastia is a common aesthetic problem faced by men with reported incidence as high as 65% with serious psychosocial impact. Although various techniques of liposculpture combined with glandular excision is the standard of treatment, many of the glandular excision techniques have inherent limitations and complications such as leaving a long scar, long operative time, contour abnormalities, and increased risk of hematoma. Here, we describe an innovative "the orange peel excision of gland (OPEG) technique" which overcomes these limitations with excellent cosmetic results. A total of 38 breasts were operated in 20 patients (18 bilateral and 2 unilateral). All the patients underwent suction-assisted liposuction and glandular excision under general anesthesia by our OPEG technique. The average operative time per breast was 60 minutes. One patient had a small hematoma which did not require evacuation. The patient satisfaction rate was 95%. The technique has reduced operative time and avoids residual gland and hematoma with excellent aesthetic outcome.

  14. A Monte Carlo model for mean glandular dose evaluation in spot compression mammography.

    PubMed

    Sarno, Antonio; Dance, David R; van Engen, Ruben E; Young, Kenneth C; Russo, Paolo; Di Lillo, Francesca; Mettivier, Giovanni; Bliznakova, Kristina; Fei, Baowei; Sechopoulos, Ioannis

    2017-07-01

    To characterize the dependence of normalized glandular dose (DgN) on various breast model and image acquisition parameters during spot compression mammography and other partial breast irradiation conditions, and evaluate alternative previously proposed dose-related metrics for this breast imaging modality. Using Monte Carlo simulations with both simple homogeneous breast models and patient-specific breasts, three different dose-related metrics for spot compression mammography were compared: the standard DgN, the normalized glandular dose to only the directly irradiated portion of the breast (DgNv), and the DgN obtained by the product of the DgN for full field irradiation and the ratio of the mid-height area of the irradiated breast to the entire breast area (DgN M ). How these metrics vary with field-of-view size, spot area thickness, x-ray energy, spot area and position, breast shape and size, and system geometry was characterized for the simple breast model and a comparison of the simple model results to those with patient-specific breasts was also performed. The DgN in spot compression mammography can vary considerably with breast area. However, the difference in breast thickness between the spot compressed area and the uncompressed area does not introduce a variation in DgN. As long as the spot compressed area is completely within the breast area and only the compressed breast portion is directly irradiated, its position and size does not introduce a variation in DgN for the homogeneous breast model. As expected, DgN is lower than DgNv for all partial breast irradiation areas, especially when considering spot compression areas within the clinically used range. DgN M underestimates DgN by 6.7% for a W/Rh spectrum at 28 kVp and for a 9 × 9 cm 2 compression paddle. As part of the development of a new breast dosimetry model, a task undertaken by the American Association of Physicists in Medicine and the European Federation of Organizations of Medical Physics, these results provide insight on how DgN and two alternative dose metrics behave with various image acquisition and model parameters. © 2017 American Association of Physicists in Medicine.

  15. 50 μm pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis.

    PubMed

    Zhao, C; Konstantinidis, A C; Zheng, Y; Anaxagoras, T; Speller, R D; Kanicki, J

    2015-12-07

    Wafer-scale CMOS active pixel sensors (APSs) have been developed recently for x-ray imaging applications. The small pixel pitch and low noise are very promising properties for medical imaging applications such as digital breast tomosynthesis (DBT). In this work, we evaluated experimentally and through modeling the imaging properties of a 50 μm pixel pitch CMOS APS x-ray detector named DynAMITe (Dynamic Range Adjustable for Medical Imaging Technology). A modified cascaded system model was developed for CMOS APS x-ray detectors by taking into account the device nonlinear signal and noise properties. The imaging properties such as modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) were extracted from both measurements and the nonlinear cascaded system analysis. The results show that the DynAMITe x-ray detector achieves a high spatial resolution of 10 mm(-1) and a DQE of around 0.5 at spatial frequencies  <1 mm(-1). In addition, the modeling results were used to calculate the image signal-to-noise ratio (SNRi) of microcalcifications at various mean glandular dose (MGD). For an average breast (5 cm thickness, 50% glandular fraction), 165 μm microcalcifications can be distinguished at a MGD of 27% lower than the clinical value (~1.3 mGy). To detect 100 μm microcalcifications, further optimizations of the CMOS APS x-ray detector, image aquisition geometry and image reconstruction techniques should be considered.

  16. Contrast-enhanced digital mammography (CEDM): imaging modeling, computer simulations, and phantom study

    NASA Astrophysics Data System (ADS)

    Chen, Biao; Jing, Zhenxue; Smith, Andrew

    2005-04-01

    Contrast enhanced digital mammography (CEDM), which is based upon the analysis of a series of x-ray projection images acquired before/after the administration of contrast agents, may provide physicians critical physiologic and morphologic information of breast lesions to determine the malignancy of lesions. This paper proposes to combine the kinetic analysis (KA) of contrast agent uptake/washout process and the dual-energy (DE) contrast enhancement together to formulate a hybrid contrast enhanced breast-imaging framework. The quantitative characteristics of materials and imaging components in the x-ray imaging chain, including x-ray tube (tungsten) spectrum, filter, breast tissues/lesions, contrast agents (non-ionized iodine solution), and selenium detector, were systematically modeled. The contrast-noise-ration (CNR) of iodinated lesions and mean absorbed glandular dose were estimated mathematically. The x-ray techniques optimization was conducted through a series of computer simulations to find the optimal tube voltage, filter thickness, and exposure levels for various breast thicknesses, breast density, and detectable contrast agent concentration levels in terms of detection efficiency (CNR2/dose). A phantom study was performed on a modified Selenia full field digital mammography system to verify the simulated results. The dose level was comparable to the dose in diagnostic mode (less than 4 mGy for an average 4.2 cm compressed breast). The results from the computer simulations and phantom study are being used to optimize an ongoing clinical study.

  17. Image quality, threshold contrast and mean glandular dose in CR mammography

    NASA Astrophysics Data System (ADS)

    Jakubiak, R. R.; Gamba, H. R.; Neves, E. B.; Peixoto, J. E.

    2013-09-01

    In many countries, computed radiography (CR) systems represent the majority of equipment used in digital mammography. This study presents a method for optimizing image quality and dose in CR mammography of patients with breast thicknesses between 45 and 75 mm. Initially, clinical images of 67 patients (group 1) were analyzed by three experienced radiologists, reporting about anatomical structures, noise and contrast in low and high pixel value areas, and image sharpness and contrast. Exposure parameters (kV, mAs and target/filter combination) used in the examinations of these patients were reproduced to determine the contrast-to-noise ratio (CNR) and mean glandular dose (MGD). The parameters were also used to radiograph a CDMAM (version 3.4) phantom (Artinis Medical Systems, The Netherlands) for image threshold contrast evaluation. After that, different breast thicknesses were simulated with polymethylmethacrylate layers and various sets of exposure parameters were used in order to determine optimal radiographic parameters. For each simulated breast thickness, optimal beam quality was defined as giving a target CNR to reach the threshold contrast of CDMAM images for acceptable MGD. These results were used for adjustments in the automatic exposure control (AEC) by the maintenance team. Using optimized exposure parameters, clinical images of 63 patients (group 2) were evaluated as described above. Threshold contrast, CNR and MGD for such exposure parameters were also determined. Results showed that the proposed optimization method was effective for all breast thicknesses studied in phantoms. The best result was found for breasts of 75 mm. While in group 1 there was no detection of the 0.1 mm critical diameter detail with threshold contrast below 23%, after the optimization, detection occurred in 47.6% of the images. There was also an average MGD reduction of 7.5%. The clinical image quality criteria were attended in 91.7% for all breast thicknesses evaluated in both patient groups. Finally, this study also concluded that the use of the AEC of the x-ray unit based on the constant dose to the detector may bring some difficulties to CR systems to operate under optimal conditions. More studies must be performed, so that the compatibility between systems and optimization methodologies can be evaluated, as well as this optimization method. Most methods are developed for phantoms, so comparative studies including clinical images must be developed.

  18. Microcalcification detectability using a bench-top prototype photon-counting breast CT based on a Si strip detector.

    PubMed

    Cho, Hyo-Min; Ding, Huanjun; Barber, William C; Iwanczyk, Jan S; Molloi, Sabee

    2015-07-01

    To investigate the feasibility of detecting breast microcalcification (μCa) with a dedicated breast computed tomography (CT) system based on energy-resolved photon-counting silicon (Si) strip detectors. The proposed photon-counting breast CT system and a bench-top prototype photon-counting breast CT system were simulated using a simulation package written in matlab to determine the smallest detectable μCa. A 14 cm diameter cylindrical phantom made of breast tissue with 20% glandularity was used to simulate an average-sized breast. Five different size groups of calcium carbonate grains, from 100 to 180 μm in diameter, were simulated inside of the cylindrical phantom. The images were acquired with a mean glandular dose (MGD) in the range of 0.7-8 mGy. A total of 400 images was used to perform a reader study. Another simulation study was performed using a 1.6 cm diameter cylindrical phantom to validate the experimental results from a bench-top prototype breast CT system. In the experimental study, a bench-top prototype CT system was constructed using a tungsten anode x-ray source and a single line 256-pixels Si strip photon-counting detector with a pixel pitch of 100 μm. Calcium carbonate grains, with diameter in the range of 105-215 μm, were embedded in a cylindrical plastic resin phantom to simulate μCas. The physical phantoms were imaged at 65 kVp with an entrance exposure in the range of 0.6-8 mGy. A total of 500 images was used to perform another reader study. The images were displayed in random order to three blinded observers, who were asked to give a 4-point confidence rating on each image regarding the presence of μCa. The μCa detectability for each image was evaluated by using the average area under the receiver operating characteristic curve (AUC) across the readers. The simulation results using a 14 cm diameter breast phantom showed that the proposed photon-counting breast CT system can achieve high detection accuracy with an average AUC greater than 0.89 ± 0.07 for μCas larger than 120 μm in diameter at a MGD of 3 mGy. The experimental results using a 1.6 cm diameter breast phantom showed that the prototype system can achieve an average AUC greater than 0.98 ± 0.01 for μCas larger than 140 μm in diameter using an entrance exposure of 1.2 mGy. The proposed photon-counting breast CT system based on a Si strip detector can potentially offer superior image quality to detect μCa with a lower dose level than a standard two-view mammography.

  19. SU-E-I-60: Validation of An Optically Stimulated Luminescent (OSL) Dosimeter for Use in Output Exposure Control Verification of Mammography Imaging Systems.

    PubMed

    Ranger, R; Butler, P; Yahnke, C; Valentino, D

    2012-06-01

    To develop and validate an Optically Stimulated Luminescent (OSL) dosimeter for exposure control verification of x-ray projection mammography imaging systems. The active detection element of the dosimeter is a strip of OSL material 3.0 mm wide, 0.13 mm thick and 30.0 mm long with an overlying aluminum step wedge with thicknesses of 0, 0.2, 0.4 and 0.6 mm Al, encapsulated in a light-tight plastic enclosure with outer dimensions of 10.0 mm wide, 5.4 mm thick, and 54.0 mm long. The dosimeter is used in conjunction with a breast phantom for the purpose of estimating the half-value layer (HVL), entrance surface exposure (ESE), and average glandular dose (AGD) in conventional projection mammography. ESE and HVL were computed based on analysis of exposure profiles obtained from exposed strip dosimeters. The AGD was estimated by multiplying the ESE by the appropriate exposure to dose conversion factor for the thickness and % glandular tissue fraction represented by the phantom and target-filter combination employed. The accuracy and reproducibility of the ESE, HVL and AGD estimates obtained using the dosimeter positioned on the surface of the ACR phantom at the chest wall edge, was evaluated using mammography systems utilizing different imaging receptor technology, i.e. screen-film (SF), computed radiography (CR) and direct radiography (DR) and compared against results obtained using a calibrated ion chamber fitted with a mammography probe. ESE, AGD and HVL results obtained using the OSL mammography QA dosimeter agreed with results obtained using an ion chamber to within 5-10%, depending on the target-filter combination used. Repeat readings were highly consistent with a coefficient of variation = 5%. The OSL mammography QA dosimeter has been shown to effectively estimate ESE, HVL and AGD, demonstrating its usefulness for secondary monitoring of output exposure of mammography imaging systems. © 2012 American Association of Physicists in Medicine.

  20. Conventional and phase contrast x-ray imaging techniques and ultrasound imaging method in breast tumor detection: initial comparison studies using phantom

    NASA Astrophysics Data System (ADS)

    Guo, Yuran; Wu, Di; Omoumi, Farid H.; Li, Yuhua; Wong, Molly Donovan; Ghani, Muhammad U.; Zheng, Bin; Liu, Hong

    2018-02-01

    The objective of this study was to demonstrate the capability of the high-energy in-line phase contrast imaging in detecting the breast tumors which are undetectable by conventional x-ray imaging but detectable by ultrasound. Experimentally, a CIRS multipurpose breast phantom with heterogeneous 50% glandular and 50% adipose breast tissue was imaged by high-energy in-line phase contrast system, conventional x-ray system and ultrasonography machine. The high-energy in-line phase contrast projection was acquired at 120 kVp, 0.3 mAs with the focal spot size of 18.3 μm. The conventional x-ray projection was acquired at 40 kVp, 3.3 mAs with the focal spot size of 22.26 μm. Both of the x-ray imaging acquisitions were conducted with a unique mean glandular dose of 0.08 mGy. As the result, the high-energy in-line phase contrast system was able to detect one lesion-like object which was also detected by the ultrasonography. This object was spherical shape with the length of about 12.28 mm. Also, the conventional x-ray system was not able to detect any objects. This result indicated the advantages provided by high-energy in-line phase contrast over conventional x-ray system in detecting lesion-like object under the same radiation dose. To meet the needs of current clinical strategies for high-density breasts screening, breast phantoms with higher glandular densities will be employed in future studies.

  1. Changes in mammary histology and transcriptome profiles by low-dose exposure to environmental phenols at critical windows of development.

    PubMed

    Gopalakrishnan, Kalpana; Teitelbaum, Susan L; Lambertini, Luca; Wetmur, James; Manservisi, Fabiana; Falcioni, Laura; Panzacchi, Simona; Belpoggi, Fiorella; Chen, Jia

    2017-01-01

    Exposure to environmental chemicals has been linked to altered mammary development and cancer risk at high doses using animal models. Effects at low doses comparable to human exposure remain poorly understood, especially during critical developmental windows. We investigated the effects of two environmental phenols commonly used in personal care products - methyl paraben (MPB) and triclosan (TCS) - on the histology and transcriptome of normal mammary glands at low doses mimicking human exposure during critical windows of development. Sprague-Dawley rats were exposed during perinatal, prepubertal and pubertal windows, as well as from birth to lactation. Low-dose exposure to MPB and TCS induced measurable changes in both mammary histology (by Masson's Trichrome Stain) and transcriptome (by microarrays) in a window-specific fashion. Puberty represented a window of heightened sensitivity to MPB, with increased glandular tissue and changes of expression in 295 genes with significant enrichment in functions such as DNA replication and cell cycle regulation. Long-term exposure to TCS from birth to lactation was associated with increased adipose and reduced glandular and secretory tissue, with expression alterations in 993 genes enriched in pathways such as cholesterol synthesis and adipogenesis. Finally, enrichment analyses revealed that genes modified by MPB and TCS were over-represented in human breast cancer gene signatures, suggesting possible links with breast carcinogenesis. These findings highlight the issues of critical windows of susceptibility that may confer heightened sensitivity to environmental insults and implicate the potential health effects of these ubiquitous environmental chemicals in breast cancer. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Changes in Mammary Histology and Transcriptome Profiles by Low-Dose Exposure to Environmental Phenols at Critical Windows of Development1

    PubMed Central

    Gopalakrishnan, Kalpana; Teitelbaum, Susan L.; Lambertini, Luca; Wetmur, James; Manservisi, Fabiana; Falcioni, Laura; Panzacchi, Simona; Belpoggi, Fiorella; Chen, Jia

    2016-01-01

    Exposure to environmental chemicals has been linked to altered mammary development and cancer risk at high doses using animal models. Effects at low doses comparable to human exposure remain poorly understood, especially during critical developmental windows. We investigated the effects of two environmental phenols commonly used in personal care products – methyl paraben (MPB) and triclosan (TCS) – on the histology and transcriptome of normal mammary glands at low doses mimicking human exposure during critical windows of development. Sprague-Dawley rats were exposed during perinatal, prepubertal and pubertal windows, as well as from birth to lactation. Low-dose exposure to MPB and TCS induced measurable changes in both mammary histology (by Masson’s Trichrome Stain) and transcriptome (by microarrays) in a window-specific fashion. Puberty represented a window of heightened sensitivity to MPB, with increased glandular tissue and changes of expression in 295 genes with significant enrichment in functions such as DNA replication and cell cycle regulation. Long-term exposure to TCS from birth to lactation was associated with increased adipose and reduced glandular and secretory tissue, with expression alterations in 993 genes enriched in pathways such as cholesterol synthesis and adipogenesis. Finally, enrichment analyses revealed that genes modified by MPB and TCS were over-represented in human breast cancer gene signatures, suggesting possible links with breast carcinogenesis. These findings highlight the issues of critical windows of susceptibility that may confer heightened sensitivity to environmental insults and implicate the potential health effects of these ubiquitous environmental chemicals in breast cancer. PMID:27810681

  3. The sow endometrium at different stages of the oestrous cycle: studies on morphological changes and infiltration by cells of the immune system.

    PubMed

    Kaeoket, K; Persson, E; Dalin, A M

    2001-01-31

    The aim of this study was to investigate the distribution of leukocytes and the morphological changes of the sow endometrium throughout the oestrous cycle. Fifteen crossbred multiparous sows (Swedish Landrace x Swedish Yorkshire), with an average parity number of 3.4 +/- 0.7 (mean +/- S.D.) were used. Blood samples were collected from the jugular vein 1h before slaughter for analyses of oestradiol-17beta and progesterone levels. Uterine samples from the mesometrial side of both horns, taken immediately after slaughter at late dioestrus, prooestrus, oestrus, early dioestrus and dioestrus, were fixed, embedded in plastic resin and stained with toluidine blue. The surface and glandular epithelium as well as subepithelial and glandular connective tissue layers were examined by light microscopy. The significantly highest surface and the glandular epithelium were observed at oestrus and dioestrus, respectively. The largest number of capillaries (underneath the surface epithelium) was found at oestrus. In the surface epithelium, the largest number of intraepithelial lymphocytes (IELs, round nucleus) was found at early dioestrus. The largest number of lymphocytes and macrophages within the glandular epithelium were found at early dioestrus and oestrus, respectively. In the subepithelial connective tissue layer, the most common type of leukocytes during all stages was the lymphocyte. The largest numbers of lymphocytes and neutrophils were found at oestrus while the largest number of eosinophils was found at dioestrus. The dominating cells of the immune system in the connective tissue of the glandular layer were lymphocytes and macrophages. The significantly largest numbers of lymphocytes and plasma cells were found at early dioestrus and dioestrus, respectively. The number of lymphocytes in the connective tissue of the glandular layer and the number of plasma cells in the subepithelial layer were positively correlated with the plasma level of progesterone (P < or = 0.05). The numbers of capillaries and neutrophils in the subepithelial layer underneath the surface epithelium as well as the number of macrophages in both surface and glandular epithelium were positively correlated with the plasma level of oestradiol-17beta (P < or = 0.05). In conclusion, the present study showed a variation in the infiltration and distribution of lymphocytes, neutrophils, eosinophils, macrophages, mast cells and plasma cells in the sow endometrium during different stages of the oestrous cycle. Also morphological parameters (e.g. height of surface and glandular epithelium, capillaries density and degree of oedema) varied throughout the oestrous cycle.

  4. Corrigendum to "The sow endometrium at different stages of the oestrus cycle: studies on morphological changes and infiltration by cells of the immune system." [Anim. Reprod. Sci. 65 (2001) 95-114].

    PubMed

    Kaeoket, K; Persson, E; Dalin, A-M

    2002-09-16

    The aim of this study was to investigate the distribution of leukocytes and the morphological changes of the sow endometrium throughout the oestrous cycle. Fifteen crossbred multiparous sows (Swedish Landrace x Swedish Yorkshire), with an average parity number of 3.4+/-0.7 (mean+/-S.D.) were used. Blood samples were collected from the jugular vein 1 h before slaughter for analyses of oestradiol-17beta and progesterone levels. Uterine samples from the mesometrial side of both horns, taken immediately after slaughter at late dioestrus, prooestrus, oestrus, early dioestrus and dioestrus, were fixed, embedded in plastic resin and stained with toluidine blue. The surface and glandular epithelium as well as subepithelial and glandular connective tissue layers were examined by light microscopy (LM). The significantly highest surface and the glandular epithelium were observed at oestrus and dioestrus, respectively. The largest number of capillaries (underneath the surface epithelium) was found at oestrus. In the surface epithelium, the largest number of intraepithelial lymphocytes (IELs, round nucleus) was found at early dioestrus. The largest number of lymphocytes and macrophages within the glandular epithelium were found at early dioestrus and oestrus, respectively. In the subepithelial connective tissue layer, the most common type of leukocytes during all stages was the lymphocyte. The largest numbers of lymphocytes and neutrophils were found at oestrus while the largest number of eosinophils was found at dioestrus. The dominating cells of the immune system in the connective tissue of the glandular layer were lymphocytes and macrophages. The significantly largest numbers of lymphocytes and plasma cells were found at early dioestrus and dioestrus, respectively. The number of lymphocytes in the connective tissue of the glandular layer and the number of plasma cells in the subepithelial layer were positively correlated with the plasma level of progesterone (P < or = 0.05). The numbers of capillaries and neutrophils in the subepithelial layer underneath the surface epithelium as well as the number of macrophages in both surface and glandular epithelium were positively correlated with the plasma level of oestradiol-17beta (P < or = 0.05). In conclusion, the present study showed a variation om the infiltration and distrobution of lymphocytes, neutrophils, eosinophils, macrophages, mast cells, and plasma cells in the sow endometrium during different stages of the oestrous cycle. Also morphological parameters (e.g. height of surface and glandular epithelium, capillaries density and degree of oedema) varied throughout the oestrous cycle. Copyright 2002 Elsevier Science B.V.

  5. Evaluation of the absorbed dose to the breast using radiochromic film in a dedicated CT mammotomography system employing a quasi-monochromatic x-ray beam.

    PubMed

    Crotty, Dominic J; Brady, Samuel L; Jackson, D'Vone C; Toncheva, Greta I; Anderson, Colin E; Yoshizumi, Terry T; Tornai, Martin P

    2011-06-01

    A dual modality SPECT-CT prototype system dedicated to uncompressed breast imaging (mammotomography) has been developed. The computed tomography subsystem incorporates an ultrathick K-edge filtration technique producing a quasi-monochromatic x-ray cone beam that optimizes the dose efficiency of the system for lesion imaging in an uncompressed breast. Here, the absorbed dose in various geometric phantoms and in an uncompressed and pendant cadaveric breast using a normal tomographic cone beam imaging protocol is characterized using both thermoluminescent dosimeter (TLD) measurements and ionization chamber-calibrated radiochromic film. Initially, two geometric phantoms and an anthropomorphic breast phantom are filled in turn with oil and water to simulate the dose to objects that mimic various breast shapes having effective density bounds of 100% fatty and glandular breast compositions, respectively. Ultimately, an excised human cadaver breast is tomographically scanned using the normal tomographic imaging protocol, and the dose to the breast tissue is evaluated and compared to the earlier phantom-based measurements. Measured trends in dose distribution across all breast geometric and anthropomorphic phantom volumes indicate lower doses in the medial breast and more proximal to the chest wall, with consequently higher doses near the lateral peripheries and nipple regions. Measured doses to the oil-filled phantoms are consistently lower across all volume shapes due to the reduced mass energy-absorption coefficient of oil relative to water. The mean measured dose to the breast cadaver, composed of adipose and glandular tissues, was measured to be 4.2 mGy compared to a mean whole-breast dose of 3.8 and 4.5 mGy for the oil- and water-filled anthropomorphic breast phantoms, respectively. Assuming rotational symmetry due to the tomographic acquisition exposures, these results characterize the 3D dose distributions in an uncompressed human breast tissue volume for this dedicated breast imaging device and illustrate advantages of using the novel ultrathick K-edge filtered beam to minimize the dose to the breast during fully-3D imaging.

  6. Evaluation of the absorbed dose to the breast using radiochromic film in a dedicated CT mammotomography system employing a quasi-monochromatic x-ray beam

    PubMed Central

    Crotty, Dominic J.; Brady, Samuel L.; Jackson, D’Vone C.; Toncheva, Greta I.; Anderson, Colin E.; Yoshizumi, Terry T.; Tornai, Martin P.

    2011-01-01

    Purpose: A dual modality SPECT-CT prototype system dedicated to uncompressed breast imaging (mammotomography) has been developed. The computed tomography subsystem incorporates an ultrathick K-edge filtration technique producing a quasi-monochromatic x-ray cone beam that optimizes the dose efficiency of the system for lesion imaging in an uncompressed breast. Here, the absorbed dose in various geometric phantoms and in an uncompressed and pendant cadaveric breast using a normal tomographic cone beam imaging protocol is characterized using both thermoluminescent dosimeter (TLD) measurements and ionization chamber-calibrated radiochromic film. Methods: Initially, two geometric phantoms and an anthropomorphic breast phantom are filled in turn with oil and water to simulate the dose to objects that mimic various breast shapes having effective density bounds of 100% fatty and glandular breast compositions, respectively. Ultimately, an excised human cadaver breast is tomographically scanned using the normal tomographic imaging protocol, and the dose to the breast tissue is evaluated and compared to the earlier phantom-based measurements. Results: Measured trends in dose distribution across all breast geometric and anthropomorphic phantom volumes indicate lower doses in the medial breast and more proximal to the chest wall, with consequently higher doses near the lateral peripheries and nipple regions. Measured doses to the oil-filled phantoms are consistently lower across all volume shapes due to the reduced mass energy-absorption coefficient of oil relative to water. The mean measured dose to the breast cadaver, composed of adipose and glandular tissues, was measured to be 4.2 mGy compared to a mean whole-breast dose of 3.8 and 4.5 mGy for the oil- and water-filled anthropomorphic breast phantoms, respectively. Conclusions: Assuming rotational symmetry due to the tomographic acquisition exposures, these results characterize the 3D dose distributions in an uncompressed human breast tissue volume for this dedicated breast imaging device and illustrate advantages of using the novel ultrathick K-edge filtered beam to minimize the dose to the breast during fully-3D imaging. PMID:21815398

  7. Intestinal radiation injury: the lower bowel syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, M.F.; Ruemmler, P.S.; Beamer, J.L.

    1975-01-01

    Newborn, weanling, and adult rats were gavaged with the strong beta emitting nuclide complex ruthenium-106/rhodium-106. The LD/sub 50/ doses obtained were 2, 20, and 9 mCi/kg. Average survival times were 10, 4.5, and 8.4 days respectively. Deaths of weanlings and adults were caused by damage to the large bowel but damage to the lower ileum caused by incorporation of /sup 106/Ru into the epithelium was usually more severe than large bowel injury in the neonates. Beagle dogs given /sup 106/Ru per os showed an LD/sub 50/ of approximately 3.7 mCi/kg, and an average survival time of about 15 days. Themore » symptoms exhibited by this large animal species differed markedly from that seen in rodents, being expressed mainly by vomiting, anorexia, and a bloody diarrhea that often persisted for 3 or 4 weeks after /sup 106/Ru ingestion. Damage to the colon was severe, consisting of a flattening of the mucosa, and a complete loss of glandular structures. In the animals that survived high doses a chronic ulcerative colitis persisted which showed little tendency to repair during the 60 day observation period. These results indicate that the radiosensitivity of the G.I. tract to ingested ''non-absorbed'' radionuclide is dependent on both age, and the passage time of the contents through the gastrointestinal tract; damage being confined almost exclusively to the lower bowel. Further, they suggest that the response of a large animal, and perhaps man, to an ingested lethal dose of a nuclide may be very different than has been observed in small animals.« less

  8. VITAMIN AND THYROID STATUS IN ARCTIC GRAYLING (THYMALLUS ARCTICUS) EXPOSED TO DOSES OF 3, 3', 4, 4'-TETRACHLOROBIPHENYL THAT INDUCE THE PHASE I ENZYME SYSTEM

    EPA Science Inventory

    Induction of phase I biotransformation enzymes is recognized as a hallmark response in fish exposed to coplanar PCBs. Depletions of vitamins A and E and disrupted thyroid hormone and glandular structure secondary to this induction have not yet been examined in an arctic fish spec...

  9. SU-F-T-58: Dosimetric Evaluation of Breast Tissue Composition for Electronic Brachytherapy (BET) Source In High Dose Rate Accelerated Partial Breast (APBI) Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, W; Johnson, D; Ahmad, S

    Purpose: To quantitatively evaluate the dosimetric impact of differing breast tissue compositions for electronic brachytherapy source for high dose rate accelerated partial breast irradiation. Methods: A series of Monte Carlo Simulation were created using the GEANT4 toolkit (version 10.0). The breast phantom was modeled as a semi-circle with a radius of 5.0 cm. A water balloon with a radius of 1.5 cm was located in the phantom with the Xoft AxxentTM EBT source placed at center as a point source. A mixed of two tissue types (adipose and glandular tissue) was assigned as the materials for the breast phantom withmore » different weight ratios. The proportionality of glandular and adipose tissue was simulated in four different fashions, 80/20, 70/30, 50/50 and 30/70 respectively. The custom energy spectrum for the 50 kVp XOFT source was provided via the manufacturer and used to generate incident photons. The dose distributions were recorded using a parallel three dimensional mesh with a size of 30 × 30 × 30 cm3 with 1 × 1 × 1 mm3 voxels. The simulated doses absorbed along the transverse axis were normalized at the distance of 1 cm and then compared with the calculations using standard TG-43 formalism. Results: All simulations showed underestimation of dose beyond balloon surface compared to standard TG-43 calculations. The maximum percentage differences within 2 cm distance from balloon surface were found to be 18%, 11%, 10% and 8% for the fat breast (30/70), standard breast (50/50), dense breast (70/30 and 80/20), respectively. Conclusion: The accuracy of dose calculations for low energy EBT source was limited when considering tissue heterogeneous composition. The impact of atomic number on photo-electric effect for lower energy Brachytherapy source is not accounted for and resulting in significant errors in dose calculation.« less

  10. Initial In Vivo Quantification of Tc-99m Sestamibi Uptake as a Function of Tissue Type in Healthy Breasts Using Dedicated Breast SPECT-CT

    PubMed Central

    Mann, Steve D.; Perez, Kristy L.; McCracken, Emily K. E.; Shah, Jainil P.; Wong, Terence Z.; Tornai, Martin P.

    2012-01-01

    A pilot study is underway to quantify in vivo the uptake and distribution of Tc-99m Sestamibi in subjects without previous history of breast cancer using a dedicated SPECT-CT breast imaging system. Subjects undergoing diagnostic parathyroid imaging studies were consented and imaged as part of this IRB-approved breast imaging study. For each of the seven subjects, one randomly selected breast was imaged prone-pendant using the dedicated, compact breast SPECT-CT system underneath the shielded patient support. Iteratively reconstructed and attenuation and/or scatter corrected images were coregistered; CT images were segmented into glandular and fatty tissue by three different methods; the average concentration of Sestamibi was determined from the SPECT data using the CT-based segmentation and previously established quantification techniques. Very minor differences between the segmentation methods were observed, and the results indicate an average image-based in vivo Sestamibi concentration of 0.10 ± 0.16 μCi/mL with no preferential uptake by glandular or fatty tissues. PMID:22956950

  11. Monte Carlo and Phantom Study of the Radiation Dose to the Body from Dedicated Computed Tomography of the Breast

    PubMed Central

    Sechopoulos, Ioannis; Vedantham, Srinivasan; Suryanarayanan, Sankararaman; D’Orsi, Carl J.; Karellas, Andrew

    2008-01-01

    Purpose To prospectively determine the radiation dose absorbed by the organs and tissues of the body during a dedicated computed tomography of the breast (DBCT) study using Monte Carlo methods and a phantom. Materials and Methods Using the Geant4 Monte Carlo toolkit, the Cristy anthropomorphic phantom and the geometry of a prototype DBCT was simulated. The simulation was used to track x-rays emitted from the source until their complete absorption or exit from the simulation limits. The interactions of the x-rays with the 65 different volumes representing organs, bones and other tissues of the anthropomorphic phantom that resulted in energy deposition were recorded. These data were used to compute the radiation dose to the organs and tissues during a complete DBCT acquisition relative to the average glandular dose to the imaged breast (ROD, relative organ dose), using the x-ray spectra proposed for DBCT imaging. The effectiveness of a lead shield for reducing the dose to the organs was investigated. Results The maximum ROD among the organs was for the ipsilateral lung with a maximum of 3.25%, followed by the heart and the thymus. Of the skeletal tissues, the sternum received the highest dose with a maximum ROD to the bone marrow of 2.24%, and to the bone surface of 7.74%. The maximum ROD to the uterus, representative of that of an early-stage fetus, was 0.026%. These maxima occurred for the highest energy x-ray spectrum (80 kVp) analyzed. A lead shield does not protect substantially the organs that receive the highest dose from DBCT. Discussion Although the dose to the organs from DBCT is substantially higher than that from planar mammography, they are comparable or considerably lower than those reached by other radiographic procedures and much lower than other CT examinations. PMID:18292479

  12. [Treatment of gynecomastia by a combined method of liposuction and semicircular periareolar incision glandular organ partial resection].

    PubMed

    Liu, Su; Kuang, Ruixia; Chen, Zhenyu; Li, Huichao; Zhang, Weina; Wang, Zhiguo; Miao, Yuanxin; Chen, Lu

    2008-12-01

    To evaluate the effect of the combined method of liposuction and semicircular periareolar incision glandular organ partial resection in the treatment of gynecomastia. From June 2004 to June 2006, 40 patients, aged 11-41 years old, were treated, with no-nodule (n = 10), nodule (n = 22) and female-breast-like with nodules (n = 8). Three patients were unilateral and 37 ones were bilateral. The levels of serum prolactin, luteinizing hormone, follicle stimulating hormone, estradiol, testosterone and cortisol were normal in 38 patients, while in the other 2 patients, the levels of serum prolactin, luteinizing hormone, follicle stimulating hormone and estradiol were higher than normal, and the testosterone level was lower. Liposuction alone was performed in 10 no-nodule patients (lipo-type), and combined liposuction and semicircular periareolar incision glandular organ partial resection were conducted in the other 30 patients (lipo-glandular type). RESULTS; Except for 2 cases in which hematoma and a small amount of effusion were found on the first and second day postoperatively and then obtained healing by first intention right after hematoma removal in time, all the other patients incisions obtained healing by first intention. Nipple numbness occurred in 3 cases on the first day postoperatively and no special treatment was conducted. There was still nipple hypesthesia in these 3 cases after 6-month follow-up. There were no complications such as hematoma, effusion, nipple and mammary areola necrosis, and nipple hypesthesia in other patients. All the 40 patients were followed up for 6-24 months (13 months on average). They were satisfied with their chest figures and no recurrence was observed. The combined method of liposuction and semicircular periareolar incision glandular organ partial resection in the treatment of gynecomastia has many advantages, such as safe, micro-scars, natural and beautiflhl male breast figures as well as high patients' satisfaction.

  13. Feasibility of estimating volumetric breast density from mammographic x-ray spectra using a cadmium telluride photon-counting detector.

    PubMed

    Ghammraoui, Bahaa; Badal, Andreu; Glick, Stephen J

    2018-06-03

    Mammographic density of glandular breast tissue has a masking effect that can reduce lesion detection accuracy and is also a strong risk factor for breast cancer. Therefore, accurate quantitative estimation of breast density is clinically important. In this study, we investigate experimentally the feasibility of quantifying volumetric breast density with spectral mammography using a CdTe-based photon-counting detector. To demonstrate proof-of-principle, this study was carried out using the single pixel Amptek XR-100T-CdTe detector. The total number of x rays recorded by the detector from a single pencil-beam projection through 50%/50% of adipose/glandular mass fraction-equivalent phantoms was measured. Material decomposition assuming two, four, and eight energy bins was then applied to characterize the inspected phantom into adipose and glandular using log-likelihood estimation, taking into account the polychromatic source, the detector response function, and the energy-dependent attenuation. Measurement tests were carried out for different doses, kVp settings, and different breast sizes. For dose of 1 mGy and above, the percent relative root mean square (RMS) errors of the estimated breast density was measured below 7% for all three phantom studies. It was also observed that some decrease in RMS errors was achieved using eight energy bins. For 3 and 4 cm thick phantoms, performance at 40 and 45 kVp showed similar performance. However, it was observed that 45 kVp showed better performance for a phantom thickness of 6 cm at low dose levels due to increased statistical variation at lower photon count levels with 40 kVp. The results of the current study suggest that photon-counting spectral mammography systems using CdTe detectors have the potential to be used for accurate quantification of volumetric breast density on a pixel-to-pixel basis, with an RMS error of less than 7%. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  14. Dosimetric characterization and organ dose assessment in digital breast tomosynthesis: Measurements and Monte Carlo simulations using voxel phantoms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baptista, Mariana, E-mail: marianabaptista@ctn.ist.utl.pt; Di Maria, Salvatore; Barros, Sílvia

    2015-07-15

    Purpose: Due to its capability to more accurately detect deep lesions inside the breast by removing the effect of overlying anatomy, digital breast tomosynthesis (DBT) has the potential to replace the standard mammography technique in clinical screening exams. However, the European Guidelines for DBT dosimetry are still a work in progress and there are little data available on organ doses other than to the breast. It is, therefore, of great importance to assess the dosimetric performance of DBT with respect to the one obtained with standard digital mammography (DM) systems. The aim of this work is twofold: (i) to studymore » the dosimetric properties of a combined DBT/DM system (MAMMOMAT Inspiration Siemens{sup ®}) for a tungsten/rhodium (W/Rh) anode/filter combination and (ii) to evaluate organs doses during a DBT examination. Methods: For the first task, measurements were performed in manual and automatic exposure control (AEC) modes, using two homogeneous breast phantoms: a PMMA slab phantom and a 4 cm thick breast-shaped rigid phantom, with 50% of glandular tissue in its composition. Monte Carlo (MC) simulations were performed using Monte Carlo N-Particle eXtended v.2.7.0. A MC model was implemented to mimic DM and DBT acquisitions for a wide range of x-ray spectra (24 –34 kV). This was used to calculate mean glandular dose (MGD) and to compute series of backscatter factors (BSFs) that could be inserted into the DBT dosimetric formalism proposed by Dance et al. Regarding the second aim of the study, the implemented MC model of the clinical equipment, together with a female voxel phantom (“Laura”), was used to calculate organ doses considering a typical DBT acquisition. Results were compared with a standard two-view mammography craniocaudal (CC) acquisition. Results: Considering the AEC mode, the acquisition of a single CC view results in a MGD ranging from 0.53 ± 0.07 mGy to 2.41 ± 0.31 mGy in DM mode and from 0.77 ± 0.11 mGy to 2.28 ± 0.32 mGy in DBT mode. Regarding the BSF, the results achieved may lead to a MGD correction of about 6%, contributing to the improvement of the current guidelines used in these applications. Finally, considering the MC results obtained for the organ dose study, the radiation doses found for the tissues of the body other than the breast were in the range of tens of μSv, and are in part comparable to the ones obtained in standard DM. Nevertheless, in a single DBT examination, some organs (such as lung and thyroid) receive higher doses (of about 9% and 21%, respectively) with respect to the CC DM acquisition. Conclusions: Taking into account an average breast with a thickness of 4.5 cm, the MGDs for DM and DBT acquisitions were below the achievable value (2.0 mGy) defined by the European protocol. Additionally, in the case of a fusion imaging study (DM + DBT), the MGD for a 4.5 cm thick breast is of the order of 1.88 ± 0.36 mGy. Finally, organ dose evaluations underline the need to improve awareness concerning dose estimation of DBT exams for some organs, especially when radiation risk is assessed by using the effective dose.« less

  15. Digital mammography--DQE versus optimized image quality in clinical environment: an on site study

    NASA Astrophysics Data System (ADS)

    Oberhofer, Nadia; Fracchetti, Alessandro; Springeth, Margareth; Moroder, Ehrenfried

    2010-04-01

    The intrinsic quality of the detection system of 7 different digital mammography units (5 direct radiography DR; 2 computed radiography CR), expressed by DQE, has been compared with their image quality/dose performances in clinical use. DQE measurements followed IEC 62220-1-2 using a tungsten test object for MTF determination. For image quality assessment two different methods have been applied: 1) measurement of contrast to noise ratio (CNR) according to the European guidelines and 2) contrast-detail (CD) evaluation. The latter was carried out with the phantom CDMAM ver. 3.4 and the commercial software CDMAM Analyser ver. 1.1 (both Artinis) for automated image analysis. The overall image quality index IQFinv proposed by the software has been validated. Correspondence between the two methods has been shown figuring out a linear correlation between CNR and IQFinv. All systems were optimized with respect to image quality and average glandular dose (AGD) within the constraints of automatic exposure control (AEC). For each equipment, a good image quality level was defined by means of CD analysis, and the corresponding CNR value considered as target value. The goal was to achieve for different PMMA-phantom thicknesses constant image quality, that means the CNR target value, at minimum dose. All DR systems exhibited higher DQE and significantly better image quality compared to CR systems. Generally switching, where available, to a target/filter combination with an x-ray spectrum of higher mean energy permitted dose savings at equal image quality. However, several systems did not allow to modify the AEC in order to apply optimal radiographic technique in clinical use. The best ratio image quality/dose was achieved by a unit with a-Se detector and W anode only recently available on the market.

  16. Genetic architecture of capitate glandular trichome density in florets of domesticated sunflower (Helianthus annuus L.)

    USDA-ARS?s Scientific Manuscript database

    Capitate glandular trichomes (CGT), one type of glandular trichomes, are most common in Asteraceae species. Capitate glandular trichomes can produce various secondary metabolites such as sesquiterpene lactones (STLs) and provide durable resistance to insect pests. In sunflower, CGT-based host resist...

  17. A cytocidal tissue kallikrein isolated from mouse submandibular glands.

    PubMed

    Murakami, K; Ikigai, H; Nagumo, N; Tomita, M; Shimamura, T

    1989-11-06

    A cytocidal factor against mouse thymocytes was purified from the submandibular glands of female BALB/c mice using Sephadex G-50 gel filtration chromatography and reverse-phase HPLC. SDS-PAGE and amino acid sequence analysis revealed that the cytocidal factor was mouse glandular kallikrein (mGK)-6. mGK-6 showed an optimal enzyme activity at pH 10 and a cytocidal activity against thymocytes in a dose-dependent manner.

  18. An improved light microscopical histoquantitative method for the stereological analysis of the rat ventral prostate lobe.

    PubMed

    Romppanen, T; Huttunen, E; Helminen, H J

    1980-07-01

    An improved light microscopical histoquantitative method for the analysis of the stereologic structure of the ventral lobe of the rat prostate is introduced. From paraffin-embedded tissue sections, volumetric fractions of the acinar parenchyma, the glandular epithelium, the glandular lumen, and the interacinar tissue were determined. The surface density of the glandular epithelium and the length density of the glandular tubules per cubic millimeter of tissue were also calculated. The corresponding total amount/quantity of each tissue compartment was computed for the whole ventral lobe based on the weight of the lobe. Using established stereologic laws, the height of the epithelium, the diameter of the glandular tubules, the free distance between the glandular tubules, and the distance between the glandular centers (means) were determined. The fitness of the method was tested by analyzing, in addition to normal prostates, ventral prostates of rats castrated 30 days before sacrifice.

  19. [Modern tendencies in treatment of atypical glandular hyperplasia--our and foreign experience].

    PubMed

    Ivanov, S; Kovachev, E; Tsonev, A; Abbud, A

    2010-01-01

    Our aim was to summarize our and foreign experience in the field of diagnosis, progression and modern treatment of precancer of the endometrium-the atypical glandular hyperplasia. We researched 750 cases with glandular and atypical glandular hyperplasia for 10 years period (2000-2010). The hyperplasia were followed up for progression from glandular hyperplasia into atypical glandular hyperplasia and early endometrial cancer. The hyperplasias were evaluated with or without progestagen hormonal therapy. All patients were treated by D&C before and after the hormonal treatment. The main symptom in all patients was the postmenopausal bleeding (72% from the cases). In 90% of the patients (675) there was obesity. Exogenous use of estrogens was found in 30% (225) of the patients. The cases with complex hyperplasia in 12% (65/525) progressed into atypical glandular hyperplasia and in 4% (21/525) progressed into endometrial cancer. The patients with atypical glandular hyperplasia in 60% (90/150) progressed into endometrial cancer. Remission was observed in 70% of the patients (194/278) with glandular hyperplasia and progestagen treatment. The remission was detected by the golden standart (D&C). The patients without hormonal treatment and with complex glandular hyperplasia have in 15% (37/247) remission. Except with progestagen therapy, we have also 15 patients treated with GnRh-analogs (Zoladex a 3.6 mg) for 3-6 months. For them we have 80% (12/15) remission. The glandular hyperplasia without atypical cells can be influenced by the hormonal treatment with progestagens and GnRh-analogs. Nevertheless this hormonal treatment--before and after we have to perform D&C and to follow up patients by ultrasound measuring the endometrial thickness. If the fertility plans of the patients are over and if they are in postmenopause with histological result from D&C-atypical glandular hyperplasia--we have to treat them more radically with simple total hysterectomy.

  20. Micromorphology of trichomes of Thymus malyi (Lamiaceae).

    PubMed

    Marin, M; Koko, V; Duletić-Lausević, S; Marin, P D

    2008-12-01

    Micromorphological, ultrastructural and morphometric investigations of the trichomes of Thymus malyi were carried out using a light microscope, a scanning electron microscope and a transmission electron microscope. Unbranched non-glandular trichomes, peltate and capitate glandular trichomes were described. The leaves of Thymus malyi bear non-glandular and glandular trichomes on both sides. Estimates of the volume density (i.e. their volume fraction per unit volume) of non-glandular trichomes were higher as compared to volume density of peltate and capitate glandular trichomes. Estimates of the number of these trichomes per area on sections showed that the capitate trichomes were the most abundant. Ultrastructural analyses of cell inner structure have shown numerous mitochondria, big nuclei and plastids with lipid globules and starch grains.

  1. Preliminary calculation of solar cosmic ray dose to the female breast in space mission

    NASA Technical Reports Server (NTRS)

    Shavers, Mark; Poston, John W.; Atwell, William; Hardy, Alva C.; Wilson, John W.

    1991-01-01

    No regulatory dose limits are specifically assigned for the radiation exposure of female breasts during manned space flight. However, the relatively high radiosensitivity of the glandular tissue of the breasts and its potential exposure to solar flare protons on short- and long-term missions mandate a priori estimation of the associated risks. A model for estimating exposure within the breast is developed for use in future NASA missions. The female breast and torso geometry is represented by a simple interim model. A recently developed proton dose-buildup procedure is used for estimating doses. The model considers geomagnetic shielding, magnetic-storm conditions, spacecraft shielding, and body self-shielding. Inputs to the model include proton energy spectra, spacecraft orbital parameters, STS orbiter-shielding distribution at a given position, and a single parameter allowing for variation in breast size.

  2. Breast Cancer Tissue Bioreactor for Direct Interrogation and Observation of Response to Antitumor Therapies

    DTIC Science & Technology

    2011-07-01

    into the bioreactor . Cell lines were cultured in low density 3D matrigel conditions. Mammoshere formation is dependent upon a number of...epithelial cell culture systems grown under 3D cell culture conditions that allow for mammosphere or glandular mammary acinar development. Drug...assessed whether lowering the dose would still be affective as a extracellular matrix inhibitor. For 3D cell cultures , mammospheres were allowed to

  3. [The establishment of environmental endocrine disruptors induced precocious puberty Macaca fascicularis model and the intervention of yin nourishing fire purging Chinese materia medica].

    PubMed

    Zhu, Lin; Cai, De-pei

    2012-12-01

    To establish the environmental endocrine disruptors (EEDs) induced precocious puberty macaca fascicularis model, thus verifying the antagonism of yin nourishing fire purging Chinese materia medica (YNFPCMM) against the estrogenic effects. (1) The female prepubescent monkeys at different months old were fed with high dose and low dose EEDs. By observing EEDs' estrogenic effects, the optimal age, the optimal exposure dose, and the optimal exposure time were determined. (2) Fifteen female prepubescent monkeys were randomly divided into the exposure group, the treatment group, and the control group, 5 in each group. Those in the exposure group were fed with EEDs such as nonylphenol (4-NP) and bisphenol A (BPA). Those in the treatment group were fed with EEDs and YNFPCMM. Those in the control group were fed with dissolvent such as corn oil. The therapeutic course was 4 weeks. By the end of the treatment, the serum estrogen level was measured and the maturation index of the vaginal keratinocytes was calculated. The uterus was extracted to measure the wet weight, the endometrial thickness, the ring-shaped myometrium thickness, the endometrial epithelial cells, and the glandular epithelium height. (1) Twenty month was the optimal exposure age. The low dose EEDs was the best exposure dose, and 4 weeks was the optimal exposure time. (2) Compared with the control group, the serum estrogen level obviously increased, the maturation index of the vaginal keratinocytes significantly increased, the wet uterus weight, the endometrial thickness, the ring-shaped myometrium thickness, the endometrial epithelial cells, and the glandular epithelium height significantly increased in the exposure group (P<0.05). Compared with the exposure group, the aforesaid indices significantly decreased in the treatment group (P<0.05). The EEDs induced precocious puberty macaca fascicularis model was successfully established in this study. The EEDs were proved to have estrogenic-like activities. YNFPC-MM was proved to have significant antagonism like estrogenic activities.

  4. A statistically defined anthropomorphic software breast phantom.

    PubMed

    Lau, Beverly A; Reiser, Ingrid; Nishikawa, Robert M; Bakic, Predrag R

    2012-06-01

    Digital anthropomorphic breast phantoms have emerged in the past decade because of recent advances in 3D breast x-ray imaging techniques. Computer phantoms in the literature have incorporated power-law noise to represent glandular tissue and branching structures to represent linear components such as ducts. When power-law noise is added to those phantoms in one piece, the simulated fibroglandular tissue is distributed randomly throughout the breast, resulting in dense tissue placement that may not be observed in a real breast. The authors describe a method for enhancing an existing digital anthropomorphic breast phantom by adding binarized power-law noise to a limited area of the breast. Phantoms with (0.5 mm)(3) voxel size were generated using software developed by Bakic et al. Between 0% and 40% of adipose compartments in each phantom were replaced with binarized power-law noise (β = 3.0) ranging from 0.1 to 0.6 volumetric glandular fraction. The phantoms were compressed to 7.5 cm thickness, then blurred using a 3 × 3 boxcar kernel and up-sampled to (0.1 mm)(3) voxel size using trilinear interpolation. Following interpolation, the phantoms were adjusted for volumetric glandular fraction using global thresholding. Monoenergetic phantom projections were created, including quantum noise and simulated detector blur. Texture was quantified in the simulated projections using power-spectrum analysis to estimate the power-law exponent β from 25.6 × 25.6 mm(2) regions of interest. Phantoms were generated with total volumetric glandular fraction ranging from 3% to 24%. Values for β (averaged per projection view) were found to be between 2.67 and 3.73. Thus, the range of textures of the simulated breasts covers the textures observed in clinical images. Using these new techniques, digital anthropomorphic breast phantoms can be generated with a variety of glandular fractions and patterns. β values for this new phantom are comparable with published values for breast tissue in x-ray projection modalities. The combination of conspicuous linear structures and binarized power-law noise added to a limited area of the phantom qualitatively improves its realism. © 2012 American Association of Physicists in Medicine.

  5. Breast Radiation Dose With CESM Compared With 2D FFDM and 3D Tomosynthesis Mammography.

    PubMed

    James, Judy R; Pavlicek, William; Hanson, James A; Boltz, Thomas F; Patel, Bhavika K

    2017-02-01

    We aimed to compare radiation dose received during contrast-enhanced spectral mammography (CESM) using high- and low-energy projections with radiation dose received during 2D full field digital mammography (FFDM) and 3D tomosynthesis on phantoms and patients with varying breast thickness and density. A single left craniocaudal projection was chosen to determine the doses for 6214 patients who underwent 2D FFDM, 3662 patients who underwent 3D tomosynthesis, and 173 patients who underwent CESM in this retrospective study. Dose measurements were also collected in phantoms with composition mimicking nondense and dense breast tissue. Average glandular dose (AGD) ± SD was 3.0 ± 1.1 mGy for CESM exposures at a mean breast thickness of 63 mm. At this thickness, the dose was 2.1 mGy from 2D FFDM and 2.5 mGy from 3D tomosynthesis. The nondense phantom had a mean AGD of 1.0 mGy with 2D FFDM, 1.3 mGy with 3D tomosynthesis, and 1.6 mGy with CESM. The dense breast phantom had a mean AGD of 1.3 mGy with 2D FFDM, 1.4 mGy with 3D tomosynthesis, and 2.1 mGy with CESM. At a compressed thickness of 4.5 cm, radiation exposure from CESM was approximately 25% higher in dense breast phantoms than in nondense breast phantoms. The dose in the dense phantom at a compressed thickness of 6 cm was approximately 42% higher than the dose in the nondense phantom at a compressed thickness of 4.5 cm. CESM was found to increase AGD at a mean breast thickness of 63 mm by approximately 0.9 mGy and 0.5 mGy compared with 2D FFDM and 3D tomosynthesis, respectively. Of note, CESM provides a standard image (similar to 2D FFDM) that is obtained using the low-energy projection. Overall, the AGD from CESM falls below the dose limit of 3 mGy set by Mammography Quality Standards Act regulations.

  6. Performance evaluation of a retrofit digital detector-based mammography system.

    PubMed

    Marshall, Nicholas W; van Ongeval, Chantal; Bosmans, Hilde

    2016-02-01

    A retrofit flat panel detector was integrated with a GE DMR+ analog mammography system and characterized using detective quantum efficiency (DQE). Technical system performance was evaluated using the European Guidelines protocol, followed by a limited evaluation of clinical image quality for 20 cases using image quality criteria in the European Guidelines. Optimal anode/filter selections were established using signal difference-to-noise ratio measurements. Only small differences in peak DQE were seen between the three anode/filter settings, with an average value of 0.53. For poly(methyl methacrylate) (PMMA) thicknesses above 60 mm, the Rh/Rh setting was the optimal anode/filter setting. The system required a mean glandular dose of 0.54 mGy at 30 kV Rh/Rh to reach the Acceptable gold thickness limit for 0.1 mm details. Imaging performance of the retrofit unit with the GE DMR+ is notably better than of powder based computed radiography systems and is comparable to current flat panel FFDM systems. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. Multi-Omics of Tomato Glandular Trichomes Reveals Distinct Features of Central Carbon Metabolism Supporting High Productivity of Specialized Metabolites[OPEN

    PubMed Central

    Bennewitz, Stefan; Bergau, Nick; Athmer, Benedikt; Henning, Anja; Majovsky, Petra; Jiménez-Gómez, José M.

    2017-01-01

    Glandular trichomes are metabolic cell factories with the capacity to produce large quantities of secondary metabolites. Little is known about the connection between central carbon metabolism and metabolic productivity for secondary metabolites in glandular trichomes. To address this gap in our knowledge, we performed comparative metabolomics, transcriptomics, proteomics, and 13C-labeling of type VI glandular trichomes and leaves from a cultivated (Solanum lycopersicum LA4024) and a wild (Solanum habrochaites LA1777) tomato accession. Specific features of glandular trichomes that drive the formation of secondary metabolites could be identified. Tomato type VI trichomes are photosynthetic but acquire their carbon essentially from leaf sucrose. The energy and reducing power from photosynthesis are used to support the biosynthesis of secondary metabolites, while the comparatively reduced Calvin-Benson-Bassham cycle activity may be involved in recycling metabolic CO2. Glandular trichomes cope with oxidative stress by producing high levels of polyunsaturated fatty acids, oxylipins, and glutathione. Finally, distinct mechanisms are present in glandular trichomes to increase the supply of precursors for the isoprenoid pathways. Particularly, the citrate-malate shuttle supplies cytosolic acetyl-CoA and plastidic glycolysis and malic enzyme support the formation of plastidic pyruvate. A model is proposed on how glandular trichomes achieve high metabolic productivity. PMID:28408661

  8. Leaf Trichomes Morphology of Hyptis suaveolens (L.) Poit. (LAMIACEAE)

    NASA Astrophysics Data System (ADS)

    Chatri, M.; Baktiar, A.; Mansyurdin, M.; Periadnadi, P.

    2018-04-01

    Hyptis suaveolens L. Poit is one of the plants from family Lamiaceae and is an aromatic plant. The aroma contained in plants is usually secreted by certain structures in plants, such as glandular trichomes. At this plant has been carried out observations about the type and distribution of trichomes by using light microscopy and SEM (Scanning Electron Microscopy). The results showed that the leaves of this plant are non-glandular trichomes types and glandular, either on the surface abaxial and adaxial and on the veins. Non-glandular trichomes consist of the monoselular and multicellular trichomes. While the glandular trichomes consist of peltate type, capitate type I and type II.

  9. Negative ion 'chip-based' nanospray tandem mass spectrometry for the analysis of flavonoids in glandular trichomes of Lychnophora ericoides Mart. (Asteraceae).

    PubMed

    Gobbo-Neto, Leonardo; Gates, Paul J; Lopes, Norberto P

    2008-12-01

    This paper reports a method for the analysis of secondary metabolites stored in glandular trichomes, employing negative ion 'chip-based' nanospray tandem mass spectrometry. The analyses of glandular trichomes from Lychnophora ericoides, a plant endemic to the Brazilian 'cerrado' and used in traditional medicine as an anti-inflammatory and analgesic agent, led to the identification of five flavonoids (chrysin, pinocembrin, pinostrobin, pinobanksin and 3-O-acetylpinobanksin) by direct infusion of the extracts of glandular trichomes into the nanospray ionisation source. All the flavonoids have no oxidation at ring B, which resulted in a modification of the fragmentation pathways compared with that of the oxidised 3,4-dihydroflavonoids already described in the literature. The absence of the anti-inflammatory and antioxidant di-C-glucosylflavone vicenin-2, or any other flavonoid glycosides, in the glandular trichomes was also demonstrated. The use of the 'chip-based' nanospray QqTOF apparatus is a new fast and useful tool for the identification of secondary metabolites stored in the glandular trichomes, which can be useful for chemotaxonomic studies based on metabolites from glandular trichomes.

  10. A cytotoxic serine proteinase isolated from mouse submandibular gland.

    PubMed

    Shimamura, T; Nagumo, N; Ikigai, H; Murakami, K; Okubo, S; Toda, M; Ohnishi, R; Tomita, M

    1989-08-01

    We have isolated a novel cytotoxic factor from the submandibular glands of male BALB/c mice by Sephadex G-50 gel filtration chromatography and reverse-phase HPLC. The cytotoxic factor is a serine proteinase, which belongs to the mouse glandular kallikrein (mGK) family, with an Mr of approximately 27,000. The purified serine proteinase showed cytotoxic activity against mouse thymocytes in a dose-dependent manner, and a serine proteinase inhibitor, diisopropyl fluorophosphate, blocked its cytotoxic activity.

  11. In vivo biocompatibility of the PLGA microparticles in parotid gland

    PubMed Central

    Cantín, Mario; Miranda, Patricio; Suazo Galdames, Iván; Zavando, Daniela; Arenas, Patricia; Velásquez, Luis; Vilos, Cristian

    2013-01-01

    Poly(lactic-co-glycolic acid) (PLGA) microparticles are used in various disorders for the controlled or sustained release of drugs, with the management of salivary gland pathologies possible using this technology. There is no record of the response to such microparticles in the glandular parenchyma. The purpose of this study was to assess the morphological changes in the parotid gland when injected with a single dose of PLGA microparticles. We used 12 adult female Sprague Dawley rats (Rattus norvegicus) that were injected into their right parotid gland with sterile vehicle solution (G1, n=4), 0.5 mg PLGA microparticles (G2, n=4), and 0.75 mg PLGA microparticles (G3, n=4); the microparticles were dissolved in a sterile vehicle solution. The intercalar and striated ducts lumen, the thickness of the acini and the histology aspect in terms of the parenchyma organization, cell morphology of acini and duct system, the presence of polymeric residues, and inflammatory response were determined at 14 days post-injection. The administration of the compound in a single dose modified some of the morphometric parameters of parenchyma (intercalar duct lumen and thickness of the glandular acini) but did not induce tissue inflammatory response, despite the visible presence of polymer waste. This suggests that PLGA microparticles are biocompatible with the parotid tissue, making it possible to use intraglandular controlled drug administration. PMID:24228103

  12. Segmentation of the whole breast from low-dose chest CT images

    NASA Astrophysics Data System (ADS)

    Liu, Shuang; Salvatore, Mary; Yankelevitz, David F.; Henschke, Claudia I.; Reeves, Anthony P.

    2015-03-01

    The segmentation of whole breast serves as the first step towards automated breast lesion detection. It is also necessary for automatically assessing the breast density, which is considered to be an important risk factor for breast cancer. In this paper we present a fully automated algorithm to segment the whole breast in low-dose chest CT images (LDCT), which has been recommended as an annual lung cancer screening test. The automated whole breast segmentation and potential breast density readings as well as lesion detection in LDCT will provide useful information for women who have received LDCT screening, especially the ones who have not undergone mammographic screening, by providing them additional risk indicators for breast cancer with no additional radiation exposure. The two main challenges to be addressed are significant range of variations in terms of the shape and location of the breast in LDCT and the separation of pectoral muscles from the glandular tissues. The presented algorithm achieves robust whole breast segmentation using an anatomy directed rule-based method. The evaluation is performed on 20 LDCT scans by comparing the segmentation with ground truth manually annotated by a radiologist on one axial slice and two sagittal slices for each scan. The resulting average Dice coefficient is 0.880 with a standard deviation of 0.058, demonstrating that the automated segmentation algorithm achieves results consistent with manual annotations of a radiologist.

  13. Autologous fat injection into the pectoralis major as an adjunct to surgical correction of gynecomastia.

    PubMed

    Pilanci, Ozgur; Basaran, Karaca; Aydin, Hasan Utkan; Cortuk, Oguz; Kuvat, Samet Vasfi

    2015-03-01

    Correction of gynecomastia in males is a frequently performed aesthetic procedure. Various surgical options involving the removal of excess skin, fat, or glandular tissue have been described. However, poor aesthetic outcomes, including a flat or depressed pectoral area, limit the success of these techniques. The authors sought to determine patient satisfaction with the results of upper chest augmentation by direct intrapectoral fat injection in conjunction with surgical correction of gynecomastia. In this prospective study, 26 patients underwent liposuction and glandular excision, glandular excision alone, or Benelli-type skin excision. All patients received intramuscular fat injections in predetermined zones of the pectoralis major (PM). The mean volume of fat injected was 160 mL (range, 80-220 mL per breast) bilaterally. Patients were monitored for an average of 16 months (range, 8-24 months). Hematoma formation and consequent infraareolar depression was noted in 1 patient and was corrected by secondary lipografting. Mean patient satisfaction was rated as 8.4 on a scale of 1 (unsatisfactory) to 10 (highly satisfactory). Autologous intrapectoral fat injection performed simultaneously with gynecomastia correction can produce a masculine appearance. The long-term viability of fat cells injected into the PM needs to be determined. 4 Therapeutic. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  14. Gastric tumorigenesis by a single dose of 4-(hydroxymethyl)benzenediazonium ion of Agaricus bisporus.

    PubMed Central

    Toth, B.; Nagel, D.; Ross, A.

    1982-01-01

    4-(Hydroxymethyl-benzenediazonium tetrafluoroborate was administered as a single intragastric instillation at 400 micrograms/g to Swiss albino mice. The treatment gave rise to glandular stomach tumours in incidences of 30% in females and 32% in males. Histopathologically, the tumours were classified as polypoid adenomas and adenocarcinomas. This diazonium ion is an ingredient of the cultivated mushroom of commerce, Agaricus bisporus. The implications are self-evident. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 PMID:6889885

  15. Influence of Environment on Glandular Trichomes and Composition of Essential Oil of Perovskia abrotanoides Karel.

    PubMed

    Oreizi, Elaheh; Rahiminejad, Mohammad Reza; Asghari, Gholamreza

    2014-11-01

    Perovskia abrotanoides Karel. is a medicinal plant used in Iranian folk medicine as a pain killer. Forty-one components have been identified in P. abrotanoides samples collected from Baluchistan Province, and 29 components have been recognized in samples collected from Khorasan Province. The leaves of P. abrotanoides have glandular trichomes (capitates and peltate) on both sides of the lamina. This study aimed to evaluate the variation of oil constituents of the plant and illustrate the glandular trichomes types and then show the influence of environment on oil constituents and glandular trichomes. The essential oil of the plant was obtained using hydrodistillation and the analysis of oils carried out using GC-MS. The anatomical analysis of leaves was done by fixing, coloring, and photoing the sections. Glandular trichomes composed of capitates and peltate trichomes. The essential oil composition differs. Viridiflora and neryl acetate were not identified in yellow glandular trichomes. It seems that there is no relation between anatomical characteristics of the plant leaves and its essential oil composition.

  16. Morphology, Structure, and Ontogeny of Trichomes of the Grape Genus (Vitis, Vitaceae).

    PubMed

    Ma, Zhi-Yao; Wen, Jun; Ickert-Bond, Stefanie M; Chen, Long-Qing; Liu, Xiu-Qun

    2016-01-01

    Trichomes are widely distributed on surfaces of different organs in the grape genus Vitis and are of taxonomic utility. To explore the morphology, structure and ontogeny of Vitis trichomes, we investigated the diversity and distribution of trichomes in 34 species of Vitis. Two main types of trichomes in Vitis are documented: non-glandular and glandular. Within non-glandular trichomes, ribbon and simple trichomes are found on different vegetative plant organs. The morphology and ontogeny of these types of trichomes are further examined with light microscopy and scanning electron microscopy. The ultrastructure of the glandular trichomes is explored with transmission electron microscopy. The ribbon trichomes are twisted, greatly elongated and unicellular, and this trichome type may be a morphological synapomorphy of Vitis and its closest tropical relative Ampelocissus and Pterisanthes in Vitaceae. The simple trichomes are documented in most species sampled in the genus. The glandular trichomes are multicellular, non-vascularized and composed of both epidermis and subjacent layers. We show that prickles occurring along the stems and petioles of Vitis davidii are modified glandular trichomes. We observed that glandular trichomes of V. romanetii secrete mucilage and volatile substances which trap insectes on the glands. Transmission electron microscopy indicates that metabolic products accumulate in vacuoles, the cytoplasm and intercellular spaces. We infer that glandular trichomes and young prickles are involved in the secretion of these metabolic products and the intercellular spaces may be the places of temporary storage of these secretions.

  17. Differentiating between endocervical glandular neoplasia and high grade squamous intraepithelial lesions in endocervical crypts: cytological features in ThinPrep and SurePath cervical cytology samples.

    PubMed

    Thiryayi, Sakinah A; Marshall, Janet; Rana, Durgesh N

    2009-05-01

    A recent audit at our institution revealed a higher number of cases diagnosed as endocervical glandular neoplasia on ThinPrep (TP) cervical cytology samples (9 cases) as opposed to SurePath (SP) (1 case), which on histology showed only high-grade cervical intraepithelial neoplasia (CIN) with endocervical crypt involvement (CI). We attempted to ascertain the reasons for this finding by reviewing the available slides of these cases, as well as slides of cases diagnosed as glandular neoplasia on cytology and histology; cases diagnosed as high-grade squamous intraepithelial lesions (HSIL) on cytology which had CIN with CI on histology and cases with mixed glandular and squamous abnormalities diagnosed both cytologically and histologically. Single neoplastic glandular cells and short pseudostratified strips were more prevalent in SP than TP with the cell clusters in glandular neoplasia 3-4 cells thick, in contrast to the dense crowded centre of cell groups in HSIL with CI. The cells at the periphery of groups can be misleading. Cases with HSIL and glandular neoplasia have a combination of the features of each entity in isolation. The diagnosis of glandular neoplasia remains challenging and conversion from conventional to liquid based cervical cytology requires a period of learning and adaptation, which can be facilitated by local audit and review of the cytology slides in cases with a cytology-histology mismatch. (c) 2009 Wiley-Liss, Inc.

  18. Capitate glandular trichomes of Paragutzlaffia henryi harbor new phytotoxic labdane diterpenoids.

    PubMed

    Wang, Ying; Luo, Shi-Hong; Hua, Juan; Liu, Yan; Jing, Shu-Xi; Li, Xiao-Nian; Li, Sheng-Hong

    2015-11-18

    The morphology and chemical profile of the capitate glandular trichomes (CGTs) of Paragutzlaffia henryi (Acanthaceae) were investigated. Four new labdane diterpenoids named paraguhenryisins A-D (1-4), together with the known physacoztomatin (5), were localized to the CGTs using laser microdissection coupled with cryogenic (1)H NMR and HPLC analyses and were traced and isolated from the CGT extract of inflorescences. Their structures were determined by spectroscopic methods and single-crystal X-ray diffraction. Bioassays indicated significant inhibitory effect for these diterpenoids on Arabidopsis thaliana seed germination and seedling root elongation. The most potent inhibitor, paraguhenryisin C (3), was interestingly detected in both the rhizosphere soil and water rinsed inflorescences extract of P. henryi but not the roots, with average contents in the rhizosphere soil relevant to its phytotoxic EC50 values. These results suggested that phytotoxic labdane diterpenoids in the CGTs might be released into the environment as a defensive measure for P. henryi against other competitive plants.

  19. Do growth hormone-releasing peptides act as ghrelin secretagogues?

    PubMed

    Ahnfelt-Rønne, I; Nowak, J; Olsen, U B

    2001-02-01

    NN703 is an orally active and selective growth hormone secretagogue (GHS) that was derived from growth hormone-releasing peptide-1(GHRP-1) via ipamorelin by a peptidomimetic approach and has now entered into phase II clinical trials. When the disposition in rats of NN703 and GHRP-6 was studied using whole-body autoradiography following administration of an iv dose of radiolabeled material, we found that a substantial amount of these secretagogues accumulate in the glandular part of the stomach. Because this is the site of synthesis and secretion of ghrelin, the endogenous GHS, we investigated the effect of resection of the gastrointestinal (GI) tract on growth hormone (GH) release induced by GHRP-6. This procedure significantly attenuated the GH secretion response by 60-70%. By contrast, the effect of GH-releasing hormone on GH release was not inhibited. The binding of GHRPs to the glandular part of the stomach and the blunted GH response to GHRP-6 following resection of the GI tract suggest a role for ghrelin as a mediator of part of the GH-releasing effect of GHRPs.

  20. The endometrium in breast cancer patients on tamoxifen.

    PubMed

    Dallenbach-Hellweg, G; Schmidt, D; Hellberg, P; Bourne, T; Kreuzwieser, E; Dören, M; Rydh, W; Rudenstam, G; Granberg, S

    2000-04-01

    We restudied histologically and immunohistochemically 17 endometrial carcinomas, 2 malignant mixed tumors and 180 endometria with benign changes during or after tamoxifen therapy. The carcinomas were subtyped according to the 1994 WHO-classification. Endometrial biopsies were taken only if the endometrial thickness was > 8 mm sonographically, when a polyp was seen, or for postmenopausal bleeding. About half of the endometrial specimens showed simple or cystic atrophy, 55-76% had cystic-atrophic polyps or regressive hyperplasia. Depending upon the dose of tamoxifen, 7-19% (30 mg) to 27-36% (20 mg) showed moderate glandular proliferation. 20-33% had foci of mucinous, clear cell or serous-papillary metaplasia. 68-70% revealed diffuse extensive fibrosis of the endometrial stroma. None of 11 patients biopsied before starting tamoxifen therapy had advanced endometrial glandular proliferation in the second endometrial biopsy after tamoxifen treatment. None of the 19 endometrial neoplasms after tamoxifen therapy was of the endometrioid type: 11 were mucinous adenocarcinomas, 4 clear cell carcinomas, 2 serous-papillary carcinomas, one carcinosarcoma and one malignant Mullerian mixed tumor. The reasons for discrepancies between suspicious sonograms and endometrial atrophy are discussed.

  1. Comparison of digital breast tomosynthesis and 2D digital mammography using a hybrid performance test

    NASA Astrophysics Data System (ADS)

    Cockmartin, Lesley; Marshall, Nicholas W.; Van Ongeval, Chantal; Aerts, Gwen; Stalmans, Davina; Zanca, Federica; Shaheen, Eman; De Keyzer, Frederik; Dance, David R.; Young, Kenneth C.; Bosmans, Hilde

    2015-05-01

    This paper introduces a hybrid method for performing detection studies in projection image based modalities, based on image acquisitions of target objects and patients. The method was used to compare 2D mammography and digital breast tomosynthesis (DBT) in terms of the detection performance of spherical densities and microcalcifications. The method starts with the acquisition of spheres of different glandular equivalent densities and microcalcifications of different sizes immersed in a homogeneous breast tissue simulating medium. These target objects are then segmented and the subsequent templates are fused in projection images of patients and processed or reconstructed. This results in hybrid images with true mammographic anatomy and clinically relevant target objects, ready for use in observer studies. The detection study of spherical densities used 108 normal and 178 hybrid 2D and DBT images; 156 normal and 321 hybrid images were used for the microcalcifications. Seven observers scored the presence/absence of the spheres/microcalcifications in a square region via a 5-point confidence rating scale. Detection performance in 2D and DBT was compared via ROC analysis with sub-analyses for the density of the spheres, microcalcification size, breast thickness and z-position. The study was performed on a Siemens Inspiration tomosynthesis system using patient acquisitions with an average age of 58 years and an average breast thickness of 53 mm providing mean glandular doses of 1.06 mGy (2D) and 2.39 mGy (DBT). Study results showed that breast tomosynthesis (AUC = 0.973) outperformed 2D (AUC = 0.831) for the detection of spheres (p  <  0.0001) and this applied for all spherical densities and breast thicknesses. By way of contrast, DBT was worse than 2D for microcalcification detection (AUC2D = 0.974, AUCDBT = 0.838, p  <  0.0001), with significant differences found for all sizes (150-354 µm), for breast thicknesses above 40 mm and for heights above the detector of 20 mm and above. In conclusion, the hybrid method was successfully used to produce images for a detection study; results showed breast tomosynthesis outperformed 2D for spherical densities while further optimization of DBT for microcalcifications is suggested.

  2. Morphology of glandular trichomes of Japanese catnip (Schizonepeta tenuifolia Briquet) and developmental dynamics of their secretory activity.

    PubMed

    Liu, Chanchan; Srividya, Narayanan; Parrish, Amber N; Yue, Wei; Shan, Mingqiu; Wu, Qinan; Lange, B Markus

    2018-06-01

    Schizonepeta tenuifolia Briquet, commonly known as Japanese catnip, is used for the treatment of colds, headaches, fevers, and skin rashes in traditional Asian medicine (China, Japan and Korea). The volatile oil and its constituents have various demonstrated biological activities, but there is currently limited information regarding the site of biosynthesis. Light microscopy and scanning electron microscopy indicated the presence of three distinct glandular trichome types which, based on their morphological features, are referred to as peltate, capitate and digitiform glandular trichomes. Laser scanning microscopy and 3D reconstruction demonstrated that terpenoid-producing peltate glandular trichomes contain a disk of twelve secretory cells. The oil of peltate glandular trichomes, collected by laser microdissection or using custom-made micropipettes, was demonstrated to contain (-)-pulegone, (+)-menthone and (+)-limonene as major constituents. Digitiform and capitate glandular trichomes did not contain appreciable levels of terpenoid volatiles. The yield of distilled oil from spikes was significantly (44%) higher than that from leaves, while the composition of oils was very similar. Oils collected directly from leaf peltate glandular trichomes over the course of a growing season contained primarily (-)-pulegone (>80% at 32 days after germination) in young plants, while (+)-menthone began to accumulate later (>75% at 80 days after germination), at the expense of (-)-pulegone (the levels of (+)-limonene remained fairly stable at 3-5%). The current study establishes the morphological and chemical characteristics of glandular trichome types of S. tenuifolia, and also provides the basis for unraveling the biosynthesis of essential oil in this popular medicinal plant. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Influence of Environment on Glandular Trichomes and Composition of Essential Oil of Perovskia abrotanoides Karel.

    PubMed Central

    Oreizi, Elaheh; Rahiminejad, Mohammad Reza; Asghari, Gholamreza

    2014-01-01

    Background: Perovskia abrotanoides Karel. is a medicinal plant used in Iranian folk medicine as a pain killer. Forty-one components have been identified in P. abrotanoides samples collected from Baluchistan Province, and 29 components have been recognized in samples collected from Khorasan Province. The leaves of P. abrotanoides have glandular trichomes (capitates and peltate) on both sides of the lamina. Objectives: This study aimed to evaluate the variation of oil constituents of the plant and illustrate the glandular trichomes types and then show the influence of environment on oil constituents and glandular trichomes. Materials and Methods: The essential oil of the plant was obtained using hydrodistillation and the analysis of oils carried out using GC-MS. The anatomical analysis of leaves was done by fixing, coloring, and photoing the sections. Results: Glandular trichomes composed of capitates and peltate trichomes. The essential oil composition differs. Viridiflora and neryl acetate were not identified in yellow glandular trichomes. Conclusions: It seems that there is no relation between anatomical characteristics of the plant leaves and its essential oil composition. PMID:25625046

  4. Measurement of X-ray intensity in mammography by a ferroelectric dosimeter

    NASA Astrophysics Data System (ADS)

    Alter, Albert J.

    2005-07-01

    Each year in the US over 20 million women undergo mammography, a relatively high dose x-ray examination of the breast, which is relatively sensitive to the carcinogenic effect of ionizing radiation. The radiation risk from mammography is usually expressed in terms of mean glandular dose (MGD) which is calculated as the product of measured entrance exposure (ESE) and a dose conversion factor which is a function of anode material, peak tube voltage (23 to 35 kVp), half-value layer, filtration, compressed breast thickness and breast composition. Mammographic units may have anodes made of molybdenum, rhodium or tungsten and filters of molybdenum, rhodium, or aluminum. In order to accommodate all these parameters, multiple extensive tables of conversion factors are required to cover the range of possibilities. Energy fluence and energy imparted are alternative measures of radiation hazard, which have been used in situations where geometry or filtration is unconventional such as computed tomography or fluoroscopy. Unfortunately, at the present there is no way to directly measure these quantities clinically. In radiation therapy applications, calorimetry has been used to measure energy absorbed. A ferroelectric-based detector has been described that measures energy fluence rate (x-ray intensity) for diagnostic x-ray, 50 to 140 kVp, aluminum filtered tungsten spectrum [Carvalho & Alter: IEEE Transactions 44(6) 1997]. This work explores use of ferroelectric detectors to measure energy fluence, energy fluence rate and energy imparted in mammography. A detector interfaced with a laptop computer was developed to allow measurements on clinical units of five different manufactures having targets of molybdenum, rhodium and tungsten and filters of molybdenum, rhodium, and aluminum of various thicknesses. The measurements provide the first values of energy fluence and energy imparted in mammography. These measurements are compared with conventional parameters such as entrance exposure and mean glandular dose as well as published values of energy imparted for other types of x-ray examinations. Advantage of measuring dose in terms of energy imparted in mammography are simplicity of comparison with other sources of radiation exposure and potential (relative ease) of measurement across a variety of anode and filter combinations.

  5. Gynecomastia: glandular-liposculpture through a single transaxillary one hole incision.

    PubMed

    Lee, Yung Ki; Lee, Jun Hee; Kang, Sang Yoon

    2018-04-01

    Gynecomastia is characterized by the benign proliferation of breast tissue in men. Herein, we present a new method for the treatment of gynecomastia, using ultrasound-assisted liposuction with both conventional and reverse-cutting edge tip cannulas in combination with a pull-through lipectomy technique with pituitary forceps through a single transaxillary incision. Thirty patients were treated with this technique at the author's institution from January 2010 to January 2015. Ten patients were treated with conventional surgical excision of the glandular/fibrous breast tissue combined with liposuction through a periareolar incision before January 2010. Medical records, clinical photographs and linear analog scale scores were analyzed to compare the surgical results and complications. The patients were required to rate their cosmetic outcomes based on the linear analog scale with which they rated their own surgical results; the mean overall average score indicated a good or high level of satisfaction. There were no incidences of skin necrosis, hematoma, infection and scar contracture; however, one case each of seroma and nipple inversion did occur. Operative time was reduced overall using the new technique since it is relatively simple and straightforward. According to the evaluation by the four independent researchers, the patients treated with this new technique showed statistically significant improvements in scar and nipple-areolar complex (NAC) deformity compared to those who were treated using the conventional method. Glandular liposculpture through a single transaxillary incision is an efficient and safe technique that can provide aesthetically satisfying and consistent results.

  6. Rapidly growing glandular papilloma associated with mucus production: a case report

    PubMed Central

    2014-01-01

    Background Pulmonary glandular papillomas are rare neoplasms, and their very slow or absent growth over time generally facilitates establishing the diagnosis. Case presentation In an 84-year-old woman who underwent surgery for sigmoid colon cancer, a growing solitary pulmonary nodule was identified on postoperative follow-up computed tomography. A computer tomography-guided needle biopsy was performed under suspicion that the nodule was malignant. The histopathological findings suggested a glandular papilloma. Right basilar segmentectomy was carried out, and the lesion was completely resected. Postoperative histopathological examination revealed a benign glandular papilloma accompanied by mucus retention in the surrounding alveolar region. Conclusions A malignant neoplasm is usually suspected when a pulmonary tumor shows rapid growth. However, glandular papillomas associated with mucus retention also tend to grow in some cases, and should be included in the differential diagnosis. PMID:24886616

  7. Local breast density assessment using reacquired mammographic images.

    PubMed

    García, Eloy; Diaz, Oliver; Martí, Robert; Diez, Yago; Gubern-Mérida, Albert; Sentís, Melcior; Martí, Joan; Oliver, Arnau

    2017-08-01

    The aim of this paper is to evaluate the spatial glandular volumetric tissue distribution as well as the density measures provided by Volpara™ using a dataset composed of repeated pairs of mammograms, where each pair was acquired in a short time frame and in a slightly changed position of the breast. We conducted a retrospective analysis of 99 pairs of repeatedly acquired full-field digital mammograms from 99 different patients. The commercial software Volpara™ Density Maps (Volpara Solutions, Wellington, New Zealand) is used to estimate both the global and the local glandular tissue distribution in each image. The global measures provided by Volpara™, such as breast volume, volume of glandular tissue, and volumetric breast density are compared between the two acquisitions. The evaluation of the local glandular information is performed using histogram similarity metrics, such as intersection and correlation, and local measures, such as statistics from the difference image and local gradient correlation measures. Global measures showed a high correlation (breast volume R=0.99, volume of glandular tissue R=0.94, and volumetric breast density R=0.96) regardless the anode/filter material. Similarly, histogram intersection and correlation metric showed that, for each pair, the images share a high degree of information. Regarding the local distribution of glandular tissue, small changes in the angle of view do not yield significant differences in the glandular pattern, whilst changes in the breast thickness between both acquisition affect the spatial parenchymal distribution. This study indicates that Volpara™ Density Maps is reliable in estimating the local glandular tissue distribution and can be used for its assessment and follow-up. Volpara™ Density Maps is robust to small variations of the acquisition angle and to the beam energy, although divergences arise due to different breast compression conditions. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Evaluation of effective detective quantum efficiency considering breast thickness and glandularity in prototype digital breast tomosynthesis system

    NASA Astrophysics Data System (ADS)

    Choi, Seungyeon; Kim, Ye-seul; Choi, Sunghoon; Lee, Haenghwa; Lee, Donghoon; Choi, Young-Wook; Kim, Hee-Joung

    2017-03-01

    Digital breast tomosynthesis (DBT) system is a novel imaging modality which is strongly depended on the performance of a detector. Recently, effective detective quantum efficiency (eDQE) has been introduced to solve the disadvantages of conventional DQE evaluations which do not consider clinical operating conditions. For eDQE evaluation, the variety of patient breast, especially the glandularity and thickness needs to be studied to consider different races of patient. For these reasons, eDQE in a prototype DBT system considering different breast thickness and glandularity was evaluated. In this study, we used the prototype DBT system with CsI(Tl) scintillator/CMOS flat panel digital detector developed by Korea Electrotechnology Research Institute (KERI). A scatter fraction, a transmission factor, an effective modulation transfer function (eMTF) and an effective normalized noise power spectrum (eNNPS) were measured in different thickness and glandularity of breast equivalent phantom. As results, scatter fraction increased and transmission fraction decreased by a factor of 2.09 and 6.25, respectively, as increasing glandularity and thickness. We also found that the breast phantom with small thickness presented high eMTF and low eNNPS. As results, eDQE from 4 cm thick breast phantom with 30% and 70% glandularity showed small changes from 0.20 to 0.19 at 0.1 mm-1, whereas eDQE from 50% glandularity of 3 cm and 5 cm presented relatively significant increase from 0.16 to 0.20 at 0.1 mm-1 spatial frequency. These indicated that eDQE was strongly affected by phantom thickness, but the effect of glandularity seemed to be trivial. According to our study, the whole system evaluation considering the races of patients from standard to abnormal cases is needed to be studied in future works.

  9. The feasibility of a regional CTDI{sub vol} to estimate organ dose from tube current modulated CT exams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khatonabadi, Maryam; Kim, Hyun J.; Lu, Peiyun

    Purpose: In AAPM Task Group 204, the size-specific dose estimate (SSDE) was developed by providing size adjustment factors which are applied to the Computed Tomography (CT) standardized dose metric, CTDI{sub vol}. However, that work focused on fixed tube current scans and did not specifically address tube current modulation (TCM) scans, which are currently the majority of clinical scans performed. The purpose of this study was to extend the SSDE concept to account for TCM by investigating the feasibility of using anatomic and organ specific regions of scanner output to improve accuracy of dose estimates. Methods: Thirty-nine adult abdomen/pelvis and 32more » chest scans from clinically indicated CT exams acquired on a multidetector CT using TCM were obtained with Institutional Review Board approval for generating voxelized models. Along with image data, raw projection data were obtained to extract TCM functions for use in Monte Carlo simulations. Patient size was calculated using the effective diameter described in TG 204. In addition, the scanner-reported CTDI{sub vol} (CTDI{sub vol,global}) was obtained for each patient, which is based on the average tube current across the entire scan. For the abdomen/pelvis scans, liver, spleen, and kidneys were manually segmented from the patient datasets; for the chest scans, lungs and for female models only, glandular breast tissue were segmented. For each patient organ doses were estimated using Monte Carlo Methods. To investigate the utility of regional measures of scanner output, regional and organ anatomic boundaries were identified from image data and used to calculate regional and organ-specific average tube current values. From these regional and organ-specific averages, CTDI{sub vol} values, referred to as regional and organ-specific CTDI{sub vol}, were calculated for each patient. Using an approach similar to TG 204, all CTDI{sub vol} values were used to normalize simulated organ doses; and the ability of each normalized dose to correlate with patient size was investigated. Results: For all five organs, the correlations with patient size increased when organ doses were normalized by regional and organ-specific CTDI{sub vol} values. For example, when estimating dose to the liver, CTDI{sub vol,global} yielded a R{sup 2} value of 0.26, which improved to 0.77 and 0.86, when using the regional and organ-specific CTDI{sub vol} for abdomen and liver, respectively. For breast dose, the global CTDI{sub vol} yielded a R{sup 2} value of 0.08, which improved to 0.58 and 0.83, when using the regional and organ-specific CTDI{sub vol} for chest and breasts, respectively. The R{sup 2} values also increased once the thoracic models were separated for the analysis into females and males, indicating differences between genders in this region not explained by a simple measure of effective diameter. Conclusions: This work demonstrated the utility of regional and organ-specific CTDI{sub vol} as normalization factors when using TCM. It was demonstrated that CTDI{sub vol,global} is not an effective normalization factor in TCM exams where attenuation (and therefore tube current) varies considerably throughout the scan, such as abdomen/pelvis and even thorax. These exams can be more accurately assessed for dose using regional CTDI{sub vol} descriptors that account for local variations in scanner output present when TCM is employed.« less

  10. Ultrasonic measurements of breast viscoelasticity.

    PubMed

    Sridhar, Mallika; Insana, Michael F

    2007-12-01

    In vivo measurements of the viscoelastic properties of breast tissue are described. Ultrasonic echo frames were recorded from volunteers at 5 fps while applying a uniaxial compressive force (1-20 N) within a 1 s ramp time and holding the force constant for up to 200 s. A time series of strain images was formed from the echo data, spatially averaged viscous creep curves were computed, and viscoelastic strain parameters were estimated by fitting creep curves to a second-order Voigt model. The useful strain bandwidth from this quasi-static ramp stimulus was 10(-2) < or = omega < or = 10(0) rad/s (0.0016-0.16 Hz). The stress-strain curves for normal glandular tissues are linear when the surface force applied is between 2 and 5 N. In this range, the creep response was characteristic of biphasic viscoelastic polymers, settling to a constant strain (arrheodictic) after 100 s. The average model-based retardance time constants for the viscoelastic response were 3.2 +/- 0.8 and 42.0 +/- 28 s. Also, the viscoelastic strain amplitude was approximately equal to that of the elastic strain. Above 5 N of applied force, however, the response of glandular tissue became increasingly nonlinear and rheodictic, i.e., tissue creep never reached a plateau. Contrasting in vivo breast measurements with those in gelatin hydrogels, preliminary ideas regarding the mechanisms for viscoelastic contrast are emerging.

  11. Ultrasonic measurements of breast viscoelasticity

    PubMed Central

    Sridhar, Mallika; Insana, Michael F.

    2009-01-01

    In vivo measurements of the viscoelastic properties of breast tissue are described. Ultrasonic echo frames were recorded from volunteers at 5 fps while applying a uniaxial compressive force (1–20 N) within a 1 s ramp time and holding the force constant for up to 200 s. A time series of strain images was formed from the echo data, spatially averaged viscous creep curves were computed, and viscoelastic strain parameters were estimated by fitting creep curves to a second-order Voigt model. The useful strain bandwidth from this quasi-static ramp stimulus was 10−2 ≤ ω ≤ 100 rad/s (0.0016–0.16 Hz). The stress-strain curves for normal glandular tissues are linear when the surface force applied is between 2 and 5 N. In this range, the creep response was characteristic of biphasic viscoelastic polymers, settling to a constant strain (arrheodictic) after 100 s. The average model-based retardance time constants for the viscoelastic response were 3.2±0.8 and 42.0±28 s. Also, the viscoelastic strain amplitude was approximately equal to that of the elastic strain. Above 5 N of applied force, however, the response of glandular tissue became increasingly nonlinear and rheodictic, i.e., tissue creep never reached a plateau. Contrasting in vivo breast measurements with those in gelatin hydrogels, preliminary ideas regarding the mechanisms for viscoelastic contrast are emerging. PMID:18196803

  12. Our experience with the so-called pull-through technique combined with liposuction for management of gynecomastia.

    PubMed

    Bracaglia, Roberto; Fortunato, Regina; Gentileschi, Stefano; Seccia, Antonio; Farallo, Eugenio

    2004-07-01

    Gynecomastia is a benign enlargement of male breast, common in adolescents and adults. To treat this deformity, we have been carrying out liposuction through small cutaneous incisions placed in the axilla and on the sternum. If necessary, we performed a surgical excision of glandular tissue through a periareolar incision. From 1995, we started to perform surgical excision of glandular tissue, if necessary, through the small incisions made for liposuction, thus avoiding the periareolar scars. We describe our experience with this technique, which we believe excellent for the correction of glandular and fatty glandular gynecomastia, obtaining excellent esthetic results and minimal local scarring.

  13. Identifying three ecological chemotypes of Xanthium strumarium glandular trichomes using a combined NMR and LC-MS method.

    PubMed

    Chen, Fangfang; Hao, Fuhua; Li, Changfu; Gou, Junbo; Lu, Dayan; Gong, Fujun; Tang, Huiru; Zhang, Yansheng

    2013-01-01

    Xanthanolides, as the sesquiterpene lactones, are reportedly the major components for the pharmacological properties of X. strumarium L. species. Phytochemical studies indicated that the glandular structures on the surface of plant tissues would form the primary sites for the accumulation of this class of the compounds. As the interface between plants and their natural enemies, glandular trichomes may vary with respect to which of their chemicals are sequestered against different herbivores in different ecologies. However, to date, no data are available on the chemical characterisation of X. strumarium glandular cells. In this study, the trichome secretions of the X. strumarium species originating from nineteen unique areas across eleven provinces in China, were analysed by HPLC, LC-ESI-MS and NMR. For the first time three distinct chemotypes of X. strumarium glandular trichomes were discovered along with the qualitative and quantitative evaluations of their presence of xanthanolides; these were designated glandular cell Types I, II, and III, respectively. The main xanthanolides in Type I cells were 8-epi-xanthatin and xanthumin while no xanthatin was detected. Xanthatin, 8-epi-xanthatin, and xanthumin dominated in Type II cells with comparable levels of each being present. For Type III cells, significantly higher concentrations of 8-epi-xanthatin or xanthinosin (relative to xanthatin) were detected with xanthinosin only being observed in this type. Further research will focus on understanding the ecological and molecular mechanism causing these chemotype differences in X. strumarium glandular structures.

  14. Identifying Three Ecological Chemotypes of Xanthium strumarium Glandular Trichomes Using a Combined NMR and LC-MS Method

    PubMed Central

    Gou, Junbo; Lu, Dayan; Gong, Fujun; Tang, Huiru; Zhang, Yansheng

    2013-01-01

    Xanthanolides, as the sesquiterpene lactones, are reportedly the major components for the pharmacological properties of X. strumarium L. species. Phytochemical studies indicated that the glandular structures on the surface of plant tissues would form the primary sites for the accumulation of this class of the compounds. As the interface between plants and their natural enemies, glandular trichomes may vary with respect to which of their chemicals are sequestered against different herbivores in different ecologies. However, to date, no data are available on the chemical characterisation of X. strumarium glandular cells. In this study, the trichome secretions of the X. strumarium species originating from nineteen unique areas across eleven provinces in China, were analysed by HPLC, LC-ESI-MS and NMR. For the first time three distinct chemotypes of X. strumarium glandular trichomes were discovered along with the qualitative and quantitative evaluations of their presence of xanthanolides; these were designated glandular cell Types I, II, and III, respectively. The main xanthanolides in Type I cells were 8-epi-xanthatin and xanthumin while no xanthatin was detected. Xanthatin, 8-epi-xanthatin, and xanthumin dominated in Type II cells with comparable levels of each being present. For Type III cells, significantly higher concentrations of 8-epi-xanthatin or xanthinosin (relative to xanthatin) were detected with xanthinosin only being observed in this type. Further research will focus on understanding the ecological and molecular mechanism causing these chemotype differences in X. strumarium glandular structures. PMID:24098541

  15. Estimation of breast dose reduction potential for organ-based tube current modulated CT with wide dose reduction arc

    NASA Astrophysics Data System (ADS)

    Fu, Wanyi; Sturgeon, Gregory M.; Agasthya, Greeshma; Segars, W. Paul; Kapadia, Anuj J.; Samei, Ehsan

    2017-03-01

    This study aimed to estimate the organ dose reduction potential for organ-dose-based tube current modulated (ODM) thoracic CT with wide dose reduction arc. Twenty-one computational anthropomorphic phantoms (XCAT, age range: 27- 75 years, weight range: 52.0-105.8 kg) were used to create a virtual patient population with clinical anatomic variations. For each phantom, two breast tissue compositions were simulated: 50/50 and 20/80 (glandular-to-adipose ratio). A validated Monte Carlo program was used to estimate the organ dose for standard tube current modulation (TCM) (SmartmA, GE Healthcare) and ODM (GE Healthcare) for a commercial CT scanner (Revolution, GE Healthcare) with explicitly modeled tube current modulation profile, scanner geometry, bowtie filtration, and source spectrum. Organ dose was determined using a typical clinical thoracic CT protocol. Both organ dose and CTDIvol-to-organ dose conversion coefficients (h factors) were compared between TCM and ODM. ODM significantly reduced all radiosensitive organ doses (p<0.01). The breast dose was reduced by 30+/-2%. For h factors, organs in the anterior region (e.g. thyroid, stomach) exhibited substantial decreases, and the medial, distributed, and posterior region either saw an increase or no significant change. The organ-dose-based tube current modulation significantly reduced organ doses especially for radiosensitive superficial anterior organs such as the breasts.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shi Linxi; Vedantham, Srinivasan; Karellas, Andrew

    Purpose: To determine the mean and range of location-averaged breast skin thickness using high-resolution dedicated breast CT for use in Monte Carlo-based estimation of normalized glandular dose coefficients. Methods: This study retrospectively analyzed image data from a clinical study investigating dedicated breast CT. An algorithm similar to that described by Huang et al.['The effect of skin thickness determined using breast CT on mammographic dosimetry,' Med. Phys. 35(4), 1199-1206 (2008)] was used to determine the skin thickness in 137 dedicated breast CT volumes from 136 women. The location-averaged mean breast skin thickness for each breast was estimated and the study populationmore » mean and range were determined. Pathology results were available for 132 women, and were used to investigate if the distribution of location-averaged mean breast skin thickness varied with pathology. The effect of surface fitting to account for breast curvature was also studied. Results: The study mean ({+-} interbreast SD) for breast skin thickness was 1.44 {+-} 0.25 mm (range: 0.87-2.34 mm), which was in excellent agreement with Huang et al. Based on pathology, pair-wise statistical analysis (Mann-Whitney test) indicated that at the 0.05 significance level, there were no significant difference in the location-averaged mean breast skin thickness distributions between the groups: benign vs malignant (p= 0.223), benign vs hyperplasia (p= 0.651), hyperplasia vs malignant (p= 0.229), and malignant vs nonmalignant (p= 0.172). Conclusions: Considering this study used a different clinical prototype system, and the study participants were from a different geographical location, the observed agreement between the two studies suggests that the choice of 1.45 mm thick skin layer comprising the epidermis and the dermis for breast dosimetry is appropriate. While some benign and malignant conditions could cause skin thickening, in this study cohort the location-averaged mean breast skin thickness distributions did not differ significantly with pathology. The study also underscored the importance of considering breast curvature in estimating breast skin thickness.« less

  17. Breast Tissue Characterization with Photon-counting Spectral CT Imaging: A Postmortem Breast Study

    PubMed Central

    Ding, Huanjun; Klopfer, Michael J.; Ducote, Justin L.; Masaki, Fumitaro

    2014-01-01

    Purpose To investigate the feasibility of breast tissue characterization in terms of water, lipid, and protein contents with a spectral computed tomographic (CT) system based on a cadmium zinc telluride (CZT) photon-counting detector by using postmortem breasts. Materials and Methods Nineteen pairs of postmortem breasts were imaged with a CZT-based photon-counting spectral CT system with beam energy of 100 kVp. The mean glandular dose was estimated to be in the range of 1.8–2.2 mGy. The images were corrected for pulse pile-up and other artifacts by using spectral distortion corrections. Dual-energy decomposition was then applied to characterize each breast into water, lipid, and protein contents. The precision of the three-compartment characterization was evaluated by comparing the composition of right and left breasts, where the standard error of the estimations was determined. The results of dual-energy decomposition were compared by using averaged root mean square to chemical analysis, which was used as the reference standard. Results The standard errors of the estimations of the right-left correlations obtained from spectral CT were 7.4%, 6.7%, and 3.2% for water, lipid, and protein contents, respectively. Compared with the reference standard, the average root mean square error in breast tissue composition was 2.8%. Conclusion Spectral CT can be used to accurately quantify the water, lipid, and protein contents in breast tissue in a laboratory study by using postmortem specimens. © RSNA, 2014 PMID:24814180

  18. Horner syndrome in glandular fever: a case report.

    PubMed

    West, E V; Sheerin, F; Bates, J E H M

    2016-02-01

    This study aimed to present and discuss the case of a patient with known glandular fever who presented with Horner syndrome. A 35-year-old patient with known glandular fever developed acute unilateral Horner syndrome, a previously undescribed complication of this common illness. Magnetic resonance imaging and magnetic resonance angiography showed that enlarged intra-carotid sheath lymphoid tissue was likely to be the underlying cause of sympathetic nerve disruption. The case is described, the anatomy of the sympathetic chain is discussed and possible alternative pathophysiological mechanisms are reviewed. This is the first report in the worldwide literature of Horner syndrome arising as a result of compression from enlarged lymph nodes in glandular fever.

  19. Plant Glandular Trichomes as Targets for Breeding or Engineering of Resistance to Herbivores

    PubMed Central

    Glas, Joris J.; Schimmel, Bernardus C. J.; Alba, Juan M.; Escobar-Bravo, Rocío; Schuurink, Robert C.; Kant, Merijn R.

    2012-01-01

    Glandular trichomes are specialized hairs found on the surface of about 30% of all vascular plants and are responsible for a significant portion of a plant’s secondary chemistry. Glandular trichomes are an important source of essential oils, i.e., natural fragrances or products that can be used by the pharmaceutical industry, although many of these substances have evolved to provide the plant with protection against herbivores and pathogens. The storage compartment of glandular trichomes usually is located on the tip of the hair and is part of the glandular cell, or cells, which are metabolically active. Trichomes and their exudates can be harvested relatively easily, and this has permitted a detailed study of their metabolites, as well as the genes and proteins responsible for them. This knowledge now assists classical breeding programs, as well as targeted genetic engineering, aimed to optimize trichome density and physiology to facilitate customization of essential oil production or to tune biocide activity to enhance crop protection. We will provide an overview of the metabolic diversity found within plant glandular trichomes, with the emphasis on those of the Solanaceae, and of the tools available to manipulate their activities for enhancing the plant’s resistance to pests. PMID:23235331

  20. Trichome differentiation on leaf primordia of Helianthus annuus (Asteraceae): morphology, gene expression and metabolite profile.

    PubMed

    Aschenbrenner, Anna-Katharina; Amrehn, Evelyn; Bechtel, Lisa; Spring, Otmar

    2015-04-01

    Sunflower trichomes fully develop on embryonic plumula within 3 days after start of germination. Toxic sesquiterpene lactones are produced immediately thereafter thus protecting the apical bud of the seedling against herbivory. Helianthus annuus harbors non-glandular and two different types of multicellular glandular trichomes, namely the biseriate capitate glandular trichomes and the uniseriate linear glandular trichomes. The development of capitate glandular trichomes is well known from anther tips on sunflower disk florets, but not from leaves and no information is yet available on the development of the linear glandular trichomes. Scanning electron microscopy of sunflower seedlings unravelled that within the first 40 h of seed germination all three types of trichomes started to emerge on primordia of the first true leaves. Within the following 20-30 h trichomes developed from trichoblasts to fully differentiated hairs. Gene expression studies showed that genes involved in the trichome-based sesquiterpene lactone formation were up-regulated between 72 and 96 h after start of germination. Metabolite profiling with HPLC confirmed the synthesis of sesquiterpene lactones which may contribute to protect the germinating seedlings from herbivory. The study has shown that sunflower leaf primordia can serve as a fast and easy to handle model system for the investigation of trichome development in Asteraceae.

  1. Slot scanning versus antiscatter grid in digital mammography: comparison of low-contrast performance using contrast-detail measurement

    NASA Astrophysics Data System (ADS)

    Lai, Chao-Jen; Shaw, Chris C.; Geiser, William; Kappadath, Srinivas C.; Liu, Xinming; Wang, TianPeng; Tu, Shu-Ju; Altunbas, Mustafa C.

    2004-05-01

    Slot scanning imaging techniques allow for effective scatter rejection without attenuating primary x-rays. The use of these techniques should generate better image quality for the same mean glandular dose (MGD) or a similar image quality for a lower MGD as compared to imaging techniques using an anti-scatter grid. In this study, we compared a slot scanning digital mammography system (SenoScan, Fisher Imaging Systems, Denver, CO) to a full-field digital mammography (FFDM) system used in conjunction with a 5:1 anti-scatter grid (SenoGraphe 2000D, General Electric Medical Systems, Milwaukee, WI). Images of a contrast-detail phantom (University Hospital Nijmegen, The Netherlands) were reviewed to measure the contrast-detail curves for both systems. These curves were measured at 100%, 71%, 49% and 33% of the reference mean glandular dose (MGD), as determined by photo-timing, for the Fisher system and 100% for the GE system. Soft-copy reading was performed on review workstations provided by the manufacturers. The correct observation ratios (CORs) were also computed and used to compare the performance of the two systems. The results showed that, based on the contrast-detail curves, the performance of the Fisher images, acquired at 100% and 71% of the reference MGD, was comparable to the GE images at 100% of the reference MGD. The CORs for Fisher images were 0.463 and 0.444 at 100% and 71% of the reference MGD, respectively, compared to 0.453 for the GE images at 100% of the reference MGD.

  2. Detection of occult endocervical glandular dysplasia in cervical conization specimens for squamous lesions.

    PubMed

    Sopracordevole, F; Clemente, N; Alessandrini, L; Di Giuseppe, J; Cigolot, F; Buttignol, M; Ciavattini, A; Canzonieri, V

    2017-03-01

    The aim of this work was to evaluate the incidence of occult cervical glandular intraepithelial neoplasia (CGIN) and adenocarcinoma of the cervix (AC) in women treated with CO2-laser conization for cervical intraepithelial neoplasia (CIN) or squamocellular cervical cancer (SCC). The medical records of all women with a histological diagnosis of squamous lesions of the uterine cervix (persistent CIN1, CIN2, CIN3 and SCC) who were subsequently treated with CO2-laser conization at our institution, during the period from January 1991 to December 2014, were analyzed in a retrospective case series. Among the 1004 women fulfilling the study inclusion/exclusion criteria, 77 cases (7.7%) of occult glandular lesions (CGIN and AC) were detected on the final cone specimen (48 cases of occult low-grade cervical glandular intraepithelial neoplasia (LCGIN), 25 cases of occult high-grade cervical glandular intraepithelial neoplasia (HCGIN), and four cases of occult "usual-type" AC). No difference in the mean age between women diagnosed with occult glandular lesions and women without occult glandular lesions on the final specimen emerged (39.1±9.3 vs 38.4±9.4, p=0.5). In women with occult LCGIN on cone specimen, mean follow-up of 48 months was reported (range 7-206 months) and no cases of progression to HCGIN or AC were observed. In conclusion, a relatively high rate of occult glandular lesions was found in women treated for squamous lesions. The natural history of CGIN is still uncertain and, in particular, there are some controversies as to whether LCGIN is a precursor lesion of HCGIN or AC. In this context the role of pathologists become very important since the appropriate diagnosis of these lesions could have potential implications in the clinical management of these patients. Copyright © 2017 Elsevier GmbH. All rights reserved.

  3. Marine-Lenhart syndrome in two adolescents, including one with thyroid cancer: a case series and review of the literature.

    PubMed

    Sharma, Animesh

    2017-11-27

    The coexistence of functional thyroid nodules and Graves' disease (GD) is a rare condition known as Marine-Lenhart syndrome. Thyroid cancer has been described in several adults, but never in children, with Marine-Lenhart syndrome. This paper discusses the challenges in diagnosis and the unique management of this condition in children, in the context of extant literature. In this case report, two adolescent female patients with Marine-Lenhart syndrome, aged 15 and 16 years, exhibited biochemical evidence of hyperthyroidism, and were found to have unilateral hyperfunctioning thyroid nodules via thyroid scintigraphy. Additionally, both patients showed elevated thyroid-stimulating immunoglobulins (TSI) and increased glandular activity, confirming background GD. Notably, one patient was also diagnosed with intranodular thyroid cancer upon preoperative examination. Both patients were treated via surgical resection. Summary and outlook: Diagnosis of Marine-Lenhart syndrome can be made in patients with functional thyroid nodules and increased glandular activity on thyroid scintigraphy. Standard doses of radioiodine ablation are not effective in the majority of patients and should be avoided due to the increased risk for thyroid cancer, making thyroidectomy the preferred treatment.

  4. Organ specific acute toxicity of the carcinogen trans-4-acetylaminostilbene is not correlated with macromolecular binding.

    PubMed

    Pfeifer, A; Neumann, H G

    1986-09-01

    trans-4-Acetylaminostilbene (trans-AAS) is acutely toxic in rats and lesions are produced specifically in the glandular stomach. Toxicity is slightly increased by pretreating the animals with phenobarbital (PB) and is completely prevented by pretreatment with methylcholanthrene (MC). The prostaglandin inhibitors, indomethacin and acetyl salicylic acid, do not reduce toxicity. The high efficiency of MC suggested that toxicity is caused by reactive metabolites. trans-[3H]-AAS was administered orally to untreated and to PB- or MC-pretreated female Wistar rats and target doses in different tissues were measured by means of covalent binding to proteins, RNA and DNA. Macromolecular binding in the target tissue of poisoned animals was significantly lower than in liver and kidney and comparable to other non-target tissues. Pretreatment with MC lowered macromolecular binding in all extrahepatic tissues but not in liver. These findings are not in line with tissue specific metabolic activation. The only unique property of the target tissue, glandular stomach, that we observed was a particular affinity for the systemically available parent compound. In the early phase of poisoning, tissue concentrations were exceedingly high and the stomach function was impaired.

  5. Contrast-enhanced spectral mammography: Does mammography provide additional clinical benefits or can some radiation exposure be avoided?

    PubMed

    Fallenberg, Eva Maria; Dromain, Clarisse; Diekmann, Felix; Renz, Diane M; Amer, Heba; Ingold-Heppner, Barbara; Neumann, Avidan U; Winzer, Klaus J; Bick, Ulrich; Hamm, Bernd; Engelken, Florian

    2014-07-01

    The purpose of this study was to compare contrast-enhanced spectral mammography (CESM) with mammography (MG) and combined CESM + MG in terms of detection and size estimation of histologically proven breast cancers in order to assess the potential to reduce radiation exposure. A total of 118 patients underwent MG and CESM and had final histological results. CESM was performed as a bilateral examination starting 2 min after injection of iodinated contrast medium. Three independent blinded radiologists read the CESM, MG, and CESM + MG images with an interval of at least 4 weeks to avoid case memorization. Sensitivity and size measurement correlation and differences were calculated, average glandular dose (AGD) levels were compared, and breast densities were reported. Fisher's exact and Wilcoxon tests were performed. A total of 107 imaging pairs were available for analysis. Densities were ACR1: 2, ACR2: 45, ACR3: 42, and ACR4: 18. Mean AGD was 1.89 mGy for CESM alone, 1.78 mGy for MG, and 3.67 mGy for the combination. In very dense breasts, AGD of CESM was significantly lower than MG. Sensitivity across readers was 77.9 % for MG alone, 94.7 % for CESM, and 95 % for CESM + MG. Average tumor size measurement error compared to postsurgical pathology was -0.6 mm for MG, +0.6 mm for CESM, and +4.5 mm for CESM + MG (p < 0.001 for CESM + MG vs. both modalities). CESM alone has the same sensitivity and better size assessment as CESM + MG and was significantly better than MG with only 6.2 % increase in AGD. The combination of CESM + MG led to systematic size overestimation. When a CESM examination is planned, additional MG can be avoided, with the possibility of saving up to 61 % of radiation dose, especially in patients with dense breasts.

  6. Evaluation of Mean Glandular Dose and Modulation Transfer Function for Different Tube Potentials and Target-Filter Combinations in Computed Radiography Mammography

    PubMed Central

    Abdul Aziz,, Siti Aishah; Mohd Saparudin, Abdul Khaliq; Harun, Ahmad Zaky

    2013-01-01

    Background: Different target-filter combinations in computed radiography have different impacts on the dose and image quality in digital radiography. This study aims to evaluate the mean glandular dose (MGD) and modulation transfer function (MTF) of various target-filter combinations by investigating the signal intensities of X-ray beams. Methods: General Electric (GE) Senographe DMR Plus mammography unit was used for MGD and MTF evaluation. The measured MGD was compared with the dose reference level (DRL), whereas the MTF was evaluated using ImageJ 1.46o software. A modified Mammography Accreditation Phantom RMI 156 was exposed using different target-filter combinations of molybdenum-molybdenum (Mo-Mo), molybdenum-rhodium (Mo-Rh) and rhodium-rhodium (Rh-Rh) at two different tube voltages, 26 kV and 32 kV with 50 mAs. Results: In the MGD evaluations, all target-filters gave an MGD value of < 1.5 mGy. The one-way ANOVA test showed a highly significant interaction between the MGD and the kilovoltage and target-filter material used (26 kV: F (2,12) = 49,234, P = 0.001;32 kV: F (2,12) = 89,972, P = 0.001). A Tukey post-hoc test revealed that the MGD for 26 kV and 32 kV was highly affected by the target-filter combinations. The test of homogeneity of variances indicates that the MGD varies significantly for 26 kV and 32 kV images (0.045 and 0.030 (P < 0.05), respectively). However, the one-way ANOVA for the MTF shows that no significant difference exists between the target-filter combinations used with 26 kV and 32 kV images either in parallel or perpendicular to the chest wall side F (2,189) = 0.26, P > 0.05). Conclusion: Higher tube voltage and atomic number target-filter yield higher MGD values. However, the MTF is independent of the X-ray energy and the type of target-filter combinations used. PMID:23966821

  7. Complete prostatic ablation using a two-stage laser

    NASA Astrophysics Data System (ADS)

    Sayer, Jeanie; Cromeens, Douglas M.; Price, Roger E.; Johnson, Douglas E.

    1993-05-01

    Laser photoirradiation has been delivered endoscopically for the treatment of both benign prostatic hyperplasia and early localized prostatic carcinoma. In treating carcinoma, aggressive transurethral resection of the prostate has been followed with laser irradiation to the remnants of malignant capsular disease. No attempt has been made heretofore to completely destroy the glandular prostate using laser irradiation alone. We performed a two-stage endoscopic laser prostatectomy in 6 adult mongrel dogs in an attempt to completely destroy the glandular prostate. Although no complications developed, histologic evaluation of the prostate revealed viable glandular elements in the midst of necrosis and atrophy. We conclude that in order to accomplish total ablation of the glandular prostate using laser photoirradiation, more precise thermal telemetry is needed.

  8. 14-Week toxicity and cell proliferation of methyleugenol administered by gavage to F344 rats and B6C3F1 mice.

    PubMed

    Abdo, K M; Cunningham, M L; Snell, M L; Herbert, R A; Travlos, G S; Eldridge, S R; Bucher, J R

    2001-04-01

    Methyleugenol, a food flavor and fragrance agent, was tested for toxicity in male and female F344/N rats and B6C3F1 mice. Groups of 10 males and 10 females per sex per species were administered 0, 10, 30, 100, 300 or 1000 mg methyleugenol/kg body weight in 0.5% aqueous methylcellulose by gavage, 5 days per week for 14 weeks. Additional groups of rats and mice of each sex were dosed similarly and used for hematology and clinical chemistry studies. Groups of 10 male and 10 female rats and mice received the vehicle by gavage on the same dosing schedule and served as vehicle controls. For serum gastrin, gastric pH and cell proliferation studies groups of 10 female rats were given 0, 37, 75 or 150 mg/kg, once daily 5 days per week for 30 or 90 days or 300 or 1000 mg/kg for 30 days; male mice were given 0, 9, 18.5, 37, 75, 150 or 300 mg/kg for 30 or 90 days. For the gastrin, pH and cell proliferation studies, groups of 10 female rats and 10 male mice were given the vehicle for 30 or 90 days and served as controls. Methyleugenol administration to rats induced erythrocyte microcytosis and thrombocytosis in male and female rats. It also caused an increase in serum alanine aminotransferase and sorbitol dehydrogenase activities and bile acid concentration, suggesting hepatocellular injury, cholestasis or altered hepatic function. Additionally, methyleugenol induced hypoproteinemia and hypoalbuminemia, evidenced by decreased total protein and albumin concentrations in both male and female rats, suggesting in inefficiency of dietary protein utilization due to methyleugenol-induced toxic effects on the liver and glandular stomach of rats and mice. The increase in gastrin and gastric pH of rats and mice given methyleugenol suggests that gastrin feedback was impaired and resulted in conditions not conducive to protein digestion. In rats, methyleugenol caused an increase in the incidences of hepatocyte cytologic alteration, cytomegaly, Kupffer cell pigmentation, mixed foci of cellular alteration and bile duct hyperplasia of the liver and atrophy and chronic inflammation of the mucosa of the glandular stomach. In mice, it caused an increase in the incidence of cytologic alteration, necrosis, bile duct hyperplasia and subacute inflammation of the liver and atrophy, degeneration, necrosis, edema, mitotic alteration, and cystic glands of the fundic region of the glandular stomach. The increased incidences of adrenal gland cortical hypertrophy and/or cytoplasmic alteration in the submandibular salivary glands, adrenal glands, testis and uterus of rats were considered secondary to the chemical-related effects observed in the liver and glandular stomach. Based on mortality, body weight gain, clinical chemistry and gross and microscopic evaluation of tissues of rats and mice, the no-observed-effect level (NOEL) of methyleugenol for both species was estimated at 10 mg/kg.

  9. Response of Sunflower (Helianthus annuus L.) Leaf Surface Defenses to Exogenous Methyl Jasmonate

    PubMed Central

    Rowe, Heather C.; Ro, Dae-kyun; Rieseberg, Loren H.

    2012-01-01

    Helianthus annuus, the common sunflower, produces a complex array of secondary compounds that are secreted into glandular trichomes, specialized structures found on leaf surfaces and anther appendages of flowers. The primary components of these trichome secretions are sesquiterpene lactones (STL), a diverse class of compounds produced abundantly by the plant family Compositae and believed to contribute to plant defense against herbivory. We treated wild and cultivated H. annuus accessions with exogenous methyl jasmonate, a plant hormone that mediates plant defense against insect herbivores and certain classes of fungal pathogens. The wild sunflower produced a higher density of glandular trichomes on its leaves than the cultivar. Comparison of the profiles of glandular trichome extracts obtained by liquid chromatography–mass spectroscopy (LC-MS) showed that wild and cultivated H. annuus were qualitatively similar in surface chemistry, although differing in the relative size and proportion of various compounds detected. Despite observing consistent transcriptional responses to methyl jasmonate treatment, we detected no significant effect on glandular trichome density or LC-MS profile in cultivated or wild sunflower, with wild sunflower exhibiting a declining trend in overall STL production and foliar glandular trichome density of jasmonate-treated plants. These results suggest that glandular trichomes and associated compounds may act as constitutive defenses or require greater levels of stimulus for induction than the observed transcriptional responses to exogenous jasmonate. Reduced defense investment in domesticated lines is consistent with predicted tradeoffs caused by selection for increased yield; future research will focus on the development of genetic resources to explicitly test the ecological roles of glandular trichomes and associated effects on plant growth and fitness. PMID:22623991

  10. Response of sunflower (Helianthus annuus L.) leaf surface defenses to exogenous methyl jasmonate.

    PubMed

    Rowe, Heather C; Ro, Dae-kyun; Rieseberg, Loren H

    2012-01-01

    Helianthus annuus, the common sunflower, produces a complex array of secondary compounds that are secreted into glandular trichomes, specialized structures found on leaf surfaces and anther appendages of flowers. The primary components of these trichome secretions are sesquiterpene lactones (STL), a diverse class of compounds produced abundantly by the plant family Compositae and believed to contribute to plant defense against herbivory. We treated wild and cultivated H. annuus accessions with exogenous methyl jasmonate, a plant hormone that mediates plant defense against insect herbivores and certain classes of fungal pathogens. The wild sunflower produced a higher density of glandular trichomes on its leaves than the cultivar. Comparison of the profiles of glandular trichome extracts obtained by liquid chromatography-mass spectroscopy (LC-MS) showed that wild and cultivated H. annuus were qualitatively similar in surface chemistry, although differing in the relative size and proportion of various compounds detected. Despite observing consistent transcriptional responses to methyl jasmonate treatment, we detected no significant effect on glandular trichome density or LC-MS profile in cultivated or wild sunflower, with wild sunflower exhibiting a declining trend in overall STL production and foliar glandular trichome density of jasmonate-treated plants. These results suggest that glandular trichomes and associated compounds may act as constitutive defenses or require greater levels of stimulus for induction than the observed transcriptional responses to exogenous jasmonate. Reduced defense investment in domesticated lines is consistent with predicted tradeoffs caused by selection for increased yield; future research will focus on the development of genetic resources to explicitly test the ecological roles of glandular trichomes and associated effects on plant growth and fitness.

  11. A Stochastic Polygons Model for Glandular Structures in Colon Histology Images.

    PubMed

    Sirinukunwattana, Korsuk; Snead, David R J; Rajpoot, Nasir M

    2015-11-01

    In this paper, we present a stochastic model for glandular structures in histology images of tissue slides stained with Hematoxylin and Eosin, choosing colon tissue as an example. The proposed Random Polygons Model (RPM) treats each glandular structure in an image as a polygon made of a random number of vertices, where the vertices represent approximate locations of epithelial nuclei. We formulate the RPM as a Bayesian inference problem by defining a prior for spatial connectivity and arrangement of neighboring epithelial nuclei and a likelihood for the presence of a glandular structure. The inference is made via a Reversible-Jump Markov chain Monte Carlo simulation. To the best of our knowledge, all existing published algorithms for gland segmentation are designed to mainly work on healthy samples, adenomas, and low grade adenocarcinomas. One of them has been demonstrated to work on intermediate grade adenocarcinomas at its best. Our experimental results show that the RPM yields favorable results, both quantitatively and qualitatively, for extraction of glandular structures in histology images of normal human colon tissues as well as benign and cancerous tissues, excluding undifferentiated carcinomas.

  12. Phenylpropanoid biosynthesis in leaves and glandular trichomes of basil (Ocimum basilicum L.).

    PubMed

    Deschamps, Cícero; Simon, James E

    2010-01-01

    Basil (Ocimum basilicum L.) essential oil phenylpropenes are synthesized and accumulate in peltate glandular trichomes and their content and composition depend on plant developmental stage. Studies on gene expression and enzymatic activity indicate that the phenylpropene biosynthetic genes are developmentally regulated. In this study, the methylchavicol accumulation in basil leaves and the enzyme activities and gene expression of both chavicol O-methyltransferase (CVOMT) and eugenol O-methyltransferase (EOMT) were investigated in all leaves at four plant developmental stages. Methylchavicol accumulation decreased over time as leaves matured. There was a significant correlation between methylchavicol accumulation and CVOMT (r(2) = 0.88) enzyme activity, suggesting that the levels of biosynthetic enzymes control the essential oil content. CVOMT and EOMT transcript expression levels, which decreased with leaf age, followed the same pattern in both whole leaves and isolated glandular trichomes, providing evidence that CVOMT transcript levels are developmentally regulated in basil glandular trichomes themselves and that differences in CVOMT expression observed in whole leaves are not solely the result of differences in glandular trichome density.

  13. The foliar trichomes of Hypoestes aristata (Vahl) Sol. ex Roem. & Schult var aristata (Acanthaceae) a widespread medicinal plant species in tropical sub-Saharan Africa: with comments on its possible phylogenetic significance.

    PubMed

    Bhatt, A; Naidoo, Y; Nicholas, A

    2010-01-01

    The micromorphology of foliar trichomes of Hypoestes aristata var. aristata was studied using stereo, light and scanning microscopy (SEM). This genus belongs to the advanced angiosperm family Acanthaceae, for which few micromorphological leaf studies exist. Results revealed both glandular and non-glandular trichomes, the latter being more abundant on leaf veins, particularly on the abaxial surface of very young leaves. With leaf maturity, the density of non-glandular trichomes decreased. Glandular trichomes were rare and of two types: long-stalked capitate and globose-like peltate trichomes. Capitate trichomes were observed only on the abaxial leaf surface, while peltate trichomes were distributed on both adaxial and abaxial leaf surfaces.

  14. Investigating the dose distribution in the uncompressed breast with a dedicated CT mammotomography system

    NASA Astrophysics Data System (ADS)

    Crotty, Dominic J.; Brady, Samuel L.; Jackson, D'Vone C.; Toncheva, Greta I.; Anderson, Colin E.; Yoshizumi, Terry T.; Tornai, Martin P.

    2010-04-01

    A dual modality SPECT-CT prototype dedicated to uncompressed breast imaging (mammotomography) has been developed. The CT subsystem incorporates an ultra-thick K-edge filtration technique producing a quasi-monochromatic x-ray cone beam to optimize the dose efficiency for uncompressed breast tomography. We characterize the absorbed dose to the breast under normal tomographic cone beam image acquisition protocols using both TLD measurements and ionization chamber-calibrated radiochromic film. Geometric and anthropomorphic breast phantoms are filled with 1000mL of water and oil to simulate different breast compositions and varying object shapes having density bounds of 100% glandular and fatty breast compositions, respectively. Doses to the water filled geometric and anthropomorphic breast phantoms for a tomographic scan range from 1.3-7.3mGy and 1.7-6.3mGy, respectively, with a mean whole-breast dose of 4.5mGy for the water-filled anthropomorphic phantom. Measured dose distribution trends indicate lower doses in the center of the breast phantoms towards the chest wall along with higher doses near the peripheries and nipple regions. Measured doses to the oil-filled phantoms are consistently lower across all volume shapes (mean dose, 3.8mGy for the anthropomorphic breast). Results agree with Monte Carlo dose estimates generated for uncompressed breast imaging and illustrate the advantages of using the novel K-edge filtered beam to minimize absorbed dose to the breast during fully-3D imaging.

  15. Experimentally determined spectral optimization for dedicated breast computed tomography.

    PubMed

    Prionas, Nicolas D; Huang, Shih-Ying; Boone, John M

    2011-02-01

    The current study aimed to experimentally identify the optimal technique factors (x-ray tube potential and added filtration material/thickness) to maximize soft-tissue contrast, microcalcification contrast, and iodine contrast enhancement using cadaveric breast specimens imaged with dedicated breast computed tomography (bCT). Secondarily, the study aimed to evaluate the accuracy of phantom materials as tissue surrogates and to characterize the change in accuracy with varying bCT technique factors. A cadaveric breast specimen was acquired under appropriate approval and scanned using a prototype bCT scanner. Inserted into the specimen were cylindrical inserts of polyethylene, water, iodine contrast medium (iodixanol, 2.5 mg/ml), and calcium hydroxyapatite (100 mg/ml). Six x-ray tube potentials (50, 60, 70, 80, 90, and 100 kVp) and three different filters (0.2 mm Cu, 1.5 mm Al, and 0.2 mm Sn) were tested. For each set of technique factors, the intensity (linear attenuation coefficient) and noise were measured within six regions of interest (ROIs): Glandular tissue, adipose tissue, polyethylene, water, iodine contrast medium, and calcium hydroxyapatite. Dose-normalized contrast to noise ratio (CNRD) was measured for pairwise comparisons among the six ROIs. Regression models were used to estimate the effect of tube potential and added filtration on intensity, noise, and CNRD. Iodine contrast enhancement was maximized using 60 kVp and 0.2 mm Cu. Microcalcification contrast and soft-tissue contrast were maximized at 60 kVp. The 0.2 mm Cu filter achieved significantly higher CNRD for iodine contrast enhancement than the other two filters (p = 0.01), but microcalcification contrast and soft-tissue contrast were similar using the copper and aluminum filters. The average percent difference in linear attenuation coefficient, across all tube potentials, for polyethylene versus adipose tissue was 1.8%, 1.7%, and 1.3% for 0.2 mm Cu, 1.5 mm Al, and 0.2 mm Sn, respectively. For water versus glandular tissue, the average percent difference was 2.7%, 3.9%, and 4.2% for the three filter types. Contrast-enhanced bCT, using injected iodine contrast medium, may be optimized for maximum contrast of enhancing lesions at 60 kVp with 0.2 mm Cu filtration. Soft-tissue contrast and microcalcification contrast may also benefit from lower tube potentials (60 kVp). The linear attenuation coefficients of water and polyethylene slightly overestimate the values of their corresponding tissues, but the reported differences may serve as guidance for dosimetry and quality assurance using tissue equivalent phantoms.

  16. Herbivory by leaf-cutter ants changes the glandular trichomes density and the volatile components in an aromatic plant model

    PubMed Central

    Mayo Marques, Marcia Ortiz; Maria Rodrigues, Tatiane

    2017-01-01

    Abstract Herbivory can induce several structural and functional alterations in the plant secretory system. Glandular trichomes are the main sites of production of volatile organic compounds (VOCs) with several chemical properties in Lamiaceae species. Ocimum species usually have three morphotypes of glandular trichomes (morphotype I is peltate and has a wide four-celled head; morphotype II is capitate and has a unicellular head; and morphotype III is capitate with a bicellular head) which produce a great amount of terpenes, although other chemical categories of substances are also produced. Despite the abundance of trichomes producing important anti-herbivory components in their leaves, the association between Ocimum species and leaf-cutter ants has been commonly registered in Brazil. We investigated the effect of leaf-cutter ant attack on the density of the glandular trichomes and on the chemistry of the VOCs released from leaves of O. gratissimum. Plants were subjected to Acromyrmex rugosus attack until 90 % of leaves were removed. After 40 days from the leaf-cutter attack, both treatments were sampled. The glandular trichome density was analysed by scanning electron microscopy. The VOCs were extracted utilizing headspace solid-phase microextraction (HS-SPME) technique and analysed by gas chromatography. Generally, the density of glandular trichomes increased in the adaxial leaf surface of the attacked plants. However, we bring novelties on this topic since we analysed the density of each morphotype separately. The morphotype I decreased in the abaxial leaf surface, and increased in the adaxial leaf surface; the morphotype II increased in both leaf surfaces; and the morphotype III decreased in the abaxial leaf surface and remained constant in the adaxial leaf surface of attacked plants. In leaves of attacked plants, the (Z)-β-ocimene increased by 50 %, the α-selinene by 13 % and the germacrene D by 126 %, whereas the eugenol decreased by 70 %. Our data point to a differential response of each glandular morphotype in O. gratissimum and are consistent with the idea of a compartmentalization of functions among the different glandular morphotypes in the plant defence against environmental factors. PMID:29218139

  17. Luminance level of a monitor: influence on detectability and detection rate of breast cancer in 2D mammography

    NASA Astrophysics Data System (ADS)

    Bemelmans, Frédéric; Rashidnasab, Alaleh; Chesterman, Frédérique; Kimpe, Tom; Bosmans, Hilde

    2016-03-01

    Purpose: To evaluate lesion detectability and reading time as a function of luminance level of the monitor. Material and Methods: 3D mass models and microcalcification clusters were simulated into ROIs of for processing mammograms. Randomly selected ROIs were subdivided in three groups according to their background glandularity: high (>30%), medium (15-30%) and low (<15%). 6 non-spiculated masses (9 - 11mm), 6 spiculated masses (5 - 7mm) and 6 microcalcification clusters (2 - 4mm) were scaled in 3D to create a range of sizes. The linear attenuation coefficient (AC) of the masses was adjusted from 100% glandular tissue to 90%, 80%, 70%, to create different contrasts. Six physicists read the full database on Barco's Coronis Uniti monitor for four different luminance levels (300, 800, 1000 and 1200 Cd/m2), using a 4-AFC tool. Percentage correct (PC) and time were computed for all different conditions. A paired t-test was performed to evaluate the effect of luminance on PC and time. A multi-factorial analysis was performed using MANOVA.. Results: Paired t-test indicated a statistically significant difference for the average time per session between 300 and 1200; 800 and 1200; 1000 and 1200 Cd/m2, for all participants combined. There was no effect on PC. MANOVA denoted significantly lower reading times for high glandularity images at 1200 Cd/m2. Both types of masses were significantly faster detected at 1200 Cd/m2, for the contrast study. In the size study, microcalcification clusters and spiculated masses had a significantly higher detection rate at 1200 Cd/m2. Conclusion: These results demonstrate a significant decrease in reading time, while detectability remained constant.

  18. Chemopreventive Activity of MGN-3/Biobran Against Chemical Induction of Glandular Stomach Carcinogenesis in Rats and Its Apoptotic Effect in Gastric Cancer Cells.

    PubMed

    Badr El-Din, Nariman K; Abdel Fattah, Salma M; Pan, Deyu; Tolentino, Lucilene; Ghoneum, Mamdooh

    2016-12-01

    In the current study, we investigated the chemopreventive activity of arabinoxylan rice bran, MGN-3/Biobran, against chemical induction of glandular stomach carcinogenesis in rats. Gastric cancer was induced by carcinogen methylnitronitrosoguanidine (MNNG), and rats received MNNG alone or MNNG plus Biobran (40 mg/kg body weight) for a total of 8 months. Averaged results from 2 separate readings showed that exposure to MNNG plus Biobran caused gastric dysplasia and cancer (adenocarcinoma) in 4.5/12 rats (9/24 readings, 37.5%), with 3.5/12 rats (7/24 readings, 29.2%) showing dysplasia and 1/12 rats (8.3%) developing adenocarcinoma. In contrast, in rats treated with MNNG alone, 8/10 (80%) developed dysplasia and adenocarcinoma, with 6/10 rats (60%) showing dysplasia and 2/10 rats (20%) developing adenocarcinoma. The effect of combining both agents was also associated with significant suppression of the expression of the tumor marker Ki-67 and remarkable induction in the apoptotic gastric cancer cells via mitochondrial-dependent pathway as indicated by the upregulation in p53 expression, Bax expression, downregulation in Bcl-2 expression, an increase in Bax/Bcl-2 ratio, and an activation of caspase-3. In addition, Biobran treatment induced cell-cycle arrest in the subG1 phase, where the hypodiploid cell population was markedly increased. Moreover, Biobran treatment protected rats against MNNG-induced significant decrease in lymphocyte levels. We conclude that Biobran provides protection against chemical induction of glandular stomach carcinogenesis in rats and may be useful for the treatment of human patients with gastric cancer. © The Author(s) 2016.

  19. Dual-energy digital mammography for calcification imaging: scatter and nonuniformity corrections.

    PubMed

    Kappadath, S Cheenu; Shaw, Chris C

    2005-11-01

    Mammographic images of small calcifications, which are often the earliest signs of breast cancer, can be obscured by overlapping fibroglandular tissue. We have developed and implemented a dual-energy digital mammography (DEDM) technique for calcification imaging under full-field imaging conditions using a commercially available aSi:H/CsI:Tl flat-panel based digital mammography system. The low- and high-energy images were combined using a nonlinear mapping function to cancel the tissue structures and generate the dual-energy (DE) calcification images. The total entrance-skin exposure and mean-glandular dose from the low- and high-energy images were constrained so that they were similar to screening-examination levels. To evaluate the DE calcification image, we designed a phantom using calcium carbonate crystals to simulate calcifications of various sizes (212-425 microm) overlaid with breast-tissue-equivalent material 5 cm thick with a continuously varying glandular-tissue ratio from 0% to 100%. We report on the effects of scatter radiation and nonuniformity in x-ray intensity and detector response on the DE calcification images. The nonuniformity was corrected by normalizing the low- and high-energy images with full-field reference images. Correction of scatter in the low- and high-energy images significantly reduced the background signal in the DE calcification image. Under the current implementation of DEDM, utilizing the mammography system and dose level tested, calcifications in the 300-355 microm size range were clearly visible in DE calcification images. Calcification threshold sizes decreased to the 250-280 microm size range when the visibility criteria were lowered to barely visible. Calcifications smaller than approximately 250 microm were usually not visible in most cases. The visibility of calcifications with our DEDM imaging technique was limited by quantum noise, not system noise.

  20. Dual-energy digital mammography for calcification imaging: Scatter and nonuniformity corrections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kappadath, S. Cheenu; Shaw, Chris C.

    Mammographic images of small calcifications, which are often the earliest signs of breast cancer, can be obscured by overlapping fibroglandular tissue. We have developed and implemented a dual-energy digital mammography (DEDM) technique for calcification imaging under full-field imaging conditions using a commercially available aSi:H/CsI:Tl flat-panel based digital mammography system. The low- and high-energy images were combined using a nonlinear mapping function to cancel the tissue structures and generate the dual-energy (DE) calcification images. The total entrance-skin exposure and mean-glandular dose from the low- and high-energy images were constrained so that they were similar to screening-examination levels. To evaluate the DEmore » calcification image, we designed a phantom using calcium carbonate crystals to simulate calcifications of various sizes (212-425 {mu}m) overlaid with breast-tissue-equivalent material 5 cm thick with a continuously varying glandular-tissue ratio from 0% to 100%. We report on the effects of scatter radiation and nonuniformity in x-ray intensity and detector response on the DE calcification images. The nonuniformity was corrected by normalizing the low- and high-energy images with full-field reference images. Correction of scatter in the low- and high-energy images significantly reduced the background signal in the DE calcification image. Under the current implementation of DEDM, utilizing the mammography system and dose level tested, calcifications in the 300-355 {mu}m size range were clearly visible in DE calcification images. Calcification threshold sizes decreased to the 250-280 {mu}m size range when the visibility criteria were lowered to barely visible. Calcifications smaller than {approx}250 {mu}m were usually not visible in most cases. The visibility of calcifications with our DEDM imaging technique was limited by quantum noise, not system noise.« less

  1. Bidirectional Secretions from Glandular Trichomes of Pyrethrum Enable Immunization of Seedlings[W

    PubMed Central

    Ramirez, Aldana M.; Stoopen, Geert; Menzel, Tila R.; Gols, Rieta; Bouwmeester, Harro J.; Dicke, Marcel; Jongsma, Maarten A.

    2012-01-01

    Glandular trichomes are currently known only to store mono- and sesquiterpene compounds in the subcuticular cavity just above the apical cells of trichomes or emit them into the headspace. We demonstrate that basipetal secretions can also occur, by addressing the organization of the biosynthesis and storage of pyrethrins in pyrethrum (Tanacetum cinerariifolium) flowers. Pyrethrum produces a diverse array of pyrethrins and sesquiterpene lactones for plant defense. The highest concentrations accumulate in the flower achenes, which are densely covered by glandular trichomes. The trichomes of mature achenes contain sesquiterpene lactones and other secondary metabolites, but no pyrethrins. However, during achene maturation, the key pyrethrin biosynthetic pathway enzyme chrysanthemyl diphosphate synthase is expressed only in glandular trichomes. We show evidence that chrysanthemic acid is translocated from trichomes to pericarp, where it is esterified into pyrethrins that accumulate in intercellular spaces. During seed maturation, pyrethrins are then absorbed by the embryo, and during seed germination, the embryo-stored pyrethrins are recruited by seedling tissues, which, for lack of trichomes, cannot produce pyrethrins themselves. The findings demonstrate that plant glandular trichomes can selectively secrete in a basipetal direction monoterpenoids, which can reach distant tissues, participate in chemical conversions, and immunize seedlings against insects and fungi. PMID:23104830

  2. The immunophenotypic relationship between the submucosal gland unit, columnar metaplasia and squamous islands in the columnar-lined oesophagus.

    PubMed

    Lörinc, Ester; Mellblom, Lennart; Öberg, Stefan

    2015-12-01

    To characterize the immunophenotypic relationship between the squamous and the glandular compartments in the oesophagus of patients with columnar-lined oesophagus (CLO). Eight tissue blocks from three oesophageal resection specimens from patients who underwent oesophagectomy for adenocarcinoma of the oesophagus were selected for immunohistochemical analysis. The markers of intestinal differentiation [CK20, CDX2 and MUC2] were all expressed in the expected pattern, solely in the glandular compartment of the resection specimens. CK4, CK17 and lysozyme were expressed in both the glandular and the squamous compartments. In addition, CK17 expression was found on both the squamous and glandular margins of the squamocolumnar transformation zones and in the submucosal gland (SMG) intraglandular and excretory ducts. There is an immunophenotypic relationship between the squamous and the glandular compartments of the CLO, with expression of lysozyme, CK4 and CK17 in both squamous and columnar cells. These overlapping immunophenotypes indicate similar differentiation paths, and link the SMG unit with the columnar metaplasia and the neosquamous islands in CLO. Our findings support the theory of a cellular origin of CLO and neosquamous islands from the SMG unit. © 2015 John Wiley & Sons Ltd.

  3. Does symptomatic primary HIV-1 infection accelerate progression to CDC stage IV disease, CD4 count below 200 x 10(6)/l, AIDS, and death from AIDS?

    PubMed Central

    Lindbäck, S.; Broström, C.; Karlsson, A.; Gaines, H.

    1994-01-01

    OBJECTIVE--To investigate the prognostic significance of symptomatic primary HIV-1 infection. DESIGN--Prospective study of homosexual men seroconverting to HIV in 1985 and 1986. Patients were followed up at least three times yearly with clinical examinations and T cell subset determinations for an average of 7.2 years. SETTING--Research project centred on attenders for treatment and screening for HIV at the Karolinska Institute, Stockholm. SUBJECTS--19 patients presenting with a glandular-fever-like illness associated with seroconversion to HIV and 29 asymptomatic seroconverters. MAIN OUTCOME MEASURES--Progression to Centers for Disease Control and Prevention stage IV disease, CD4 cell count below 200 x 10(6)/l, AIDS, and death from AIDS. RESULTS--Symptomatic seroconverters were significantly more likely to develop Centers for Disease Control and Prevention stage IV disease (95% v 66%), CD4 cell counts below 200 x 10(6)/l (84% v 55%), and AIDS (58% v 28%) and die of AIDS (53% v 7%). CONCLUSION--A glandular-fever-like illness associated with seroconversion to HIV-1 predicts accelerated progression to AIDS and other HIV related diseases. PMID:7819891

  4. Structure and properties of the glandular surface in the digestive zone of the pitcher in the carnivorous plant Nepenthes ventrata and its role in insect trapping and retention.

    PubMed

    Gorb, Elena; Kastner, Victoria; Peressadko, Andrei; Arzt, Eduard; Gaume, Laurence; Rowe, Nick; Gorb, Stanislav

    2004-08-01

    Carnivorous plants of the genus Nepenthes grow in nutrient-poor habitats and have evolved specialised trapping organs, known as pitchers. These are composed of different surface zones serving the functions of attraction, capture and digestion of insects, which represent a main source of nitrogen. To investigate the role of the glandular digestive zone in the trapping mechanism of the pitcher, structural, mechanical and physico-chemical studies were applied to N. ventrata and combined with insect behavioural experiments. It was found that the glandular surface is microscopically rough since it is regularly structured with multicellular glands situated in epidermal depressions. The presence of downward-directed 'hoods' over the upper part of glands and sloped depressions in the proximal direction of the pitcher causes a marked anisotropy of the surface. The glandular zone surface is composed of relatively stiff material (Young's modulus, 637.19+/-213.44 kPa). It is not homogeneous, in terms of adhesive properties, and contains numerous areas without adhesion as well as adhesive areas differing greatly in tenacity values (range, 1.39-28.24 kPa). The surface is readily wettable with water (contact angle, 31.9-36.0 degrees C) and has a high surface free energy (56.84-61.93 mN m(-1)) with a relatively high polar component (33.09-52.70 mN m(-1)). To examine the effect of the glandular secretion on attachment systems of insects having hairy and smooth adhesive pads, forces generated on different surfaces by Calliphora vicina flies and Pyrrhocoris apterus bugs, respectively, were measured. Flies attached equally well to both fresh and air-dried glandular surfaces whereas bugs generated a significantly lower force on the fresh glandular surface compared with the air-dried one. It is assumed that the contribution of the glandular surface to insect retention, due to its effect on insect attachment, differs depending on insect weight and the type of insect attachment system. Surface anisotropy does not facilitate effective claw interlocking so that insects possessing only claws are probably not able to cling to the glandular surface. However, stiffness of the pitcher wall material in the digestive zone can provide claw clinging via punching of the pitcher wall by claws. Small insects lacking pads may use adhesive areas on the plant surface to attach themselves, but such solitary points with very strong adhesion possibly impede their overall locomotion and chance of escape. Pad-bearing insects are presumably able to attach to smooth parts of the glandular surface located between glands. High free surface energy of the plant substrate may promote adhesion. Gland secretion may decrease attachment ability in insects with smooth adhesive pads but not influence attachment of insects with hairy attachment systems.

  5. Comparative Analysis of Leaf Trichome Structure and Composition of Epicuticular Flavonoids in Finnish Birch Species

    PubMed Central

    VALKAMA, ELENA; SALMINEN, JUHA‐PEKKA; KORICHEVA, JULIA; PIHLAJA, KALEVI

    2003-01-01

    The morphology, ultrastructure, density and distribution of trichomes on leaves of Betula pendula, B. pubescens ssp. pubescens, B. pubescens ssp. czerepanovii and B. nana were examined by means of light, scanning and transmission electron microscopy. The composition of flavonoids in ethanolic leaf surface extracts was analysed by high pressure liquid chromatography. All taxa examined contained both glandular and non‐glandular trichomes (short and/or long hairs) but differed from each other in trichome ultrastructure, density and location on the leaf. Leaves of B. pubescens were more hairy than those of B. pendula, but the latter species had a higher density of glandular trichomes. Of the two subspecies of B. pubescens, leaves of ssp. pubescens had more short hairs on the leaf surface and four times the density of glandular trichomes of leaves of ssp. czerepanovii, whereas, in the latter subspecies, short hairs occurred largely on leaf veins, as in B. nana. The glandular trichomes were peltate glands, consisting of medullar and cortical cells, which differed structurally. Cortical cells possessed numerous small, poorly developed plastids and small vacuoles, whereas medullar cells had several large plastids with well‐developed thylakoid systems and fewer vacuoles. In B. pubescens subspecies, vacuoles of the glandular cells contained osmiophilic deposits, which were probably phenolic, whereas in B. pendula, vacuoles of glandular trichomes were characterized by the presence of numerous myelin‐like membranes. The composition of epicuticular flavonoids also differed among species. The two subspecies of B. pubescens and B. nana shared the same 12 compounds, but five of these occurred only in trace amounts in B. nana. Leaf surface extracts of B. pendula contained just six flavonoids, three of which occurred only in this species. In summary, the structure, density and distribution of leaf trichomes and the composition of epicuticular flavonoids represent good taxonomic markers for Finnish birch species. PMID:12714363

  6. [Surgical treatment of precancer and cancer of endometrium].

    PubMed

    Ivanov, S; Khadzhiolov, N; Batashki, I

    2007-01-01

    Our aim was to evaluate occult presence of endometrial cancer in patients with atypical glandular hiperplasia and to compare the histological prognostic factors according to the status of the lymph nodes and the grading of the occult tumour. 306 patients were evaluated retrospectvely for the period of 1990-2007. They were operated one month after the hostological diagnostic atypical glandular hiperplasia obtained by D&C. All patients were with vaginal bleeding. The patients who had concomitant presence of endometrial hyperplasia and endometrial cancer were excluded from the study. One hundred patients (group A) with atypical glandular hyperplasia were compared with 206 patients (group B) without atypical glandular hyperplasia obtained by D&C. Mann and Witney test and chi-square test were used for statistical evaluation.. There was no difference between the age and the menopausal status in the two groups, only there was higher parity in group B. In group A patients with atypical glandular hyperlasia we found in 50% endometrial cancer intraoperatively, in 40% endometrial hyperplasia and in 10% normal endometrium. In the second group B were included the patients without atypical hyperplasia from D&C. In group B were found in 6% endometrial cancer in 44% endometrial hyperplasia and in 50% normal endometrium. In 30 patients was performed complete surgical staging. Six patients were with metastatic lymph nodes. All of them were with grading 2 (4 patients) and grading 3 (2 patients), and also with infiltration in the lymph-vascular spaces. Four patients were with nonendometrioid tumours (type 2 endometrial cancer). The careful preoperative and intraoperative evaluation of the endometrium is very important in patients with atypical glandular hyperplasia. It is reasonable to use frozen section in the time of hysterectomy for patients with atypical glandular hyperplasia. If tumour with grading 2/3 nonendometrioid cancer with lymph-vascular space invasion, is found-complete surgical staging is needed.

  7. Dual Energy Method for Breast Imaging: A Simulation Study.

    PubMed

    Koukou, V; Martini, N; Michail, C; Sotiropoulou, P; Fountzoula, C; Kalyvas, N; Kandarakis, I; Nikiforidis, G; Fountos, G

    2015-01-01

    Dual energy methods can suppress the contrast between adipose and glandular tissues in the breast and therefore enhance the visibility of calcifications. In this study, a dual energy method based on analytical modeling was developed for the detection of minimum microcalcification thickness. To this aim, a modified radiographic X-ray unit was considered, in order to overcome the limited kVp range of mammographic units used in previous DE studies, combined with a high resolution CMOS sensor (pixel size of 22.5 μm) for improved resolution. Various filter materials were examined based on their K-absorption edge. Hydroxyapatite (HAp) was used to simulate microcalcifications. The contrast to noise ratio (CNR tc ) of the subtracted images was calculated for both monoenergetic and polyenergetic X-ray beams. The optimum monoenergetic pair was 23/58 keV for the low and high energy, respectively, resulting in a minimum detectable microcalcification thickness of 100 μm. In the polyenergetic X-ray study, the optimal spectral combination was 40/70 kVp filtered with 100 μm cadmium and 1000 μm copper, respectively. In this case, the minimum detectable microcalcification thickness was 150 μm. The proposed dual energy method provides improved microcalcification detectability in breast imaging with mean glandular dose values within acceptable levels.

  8. Dual Energy Method for Breast Imaging: A Simulation Study

    PubMed Central

    2015-01-01

    Dual energy methods can suppress the contrast between adipose and glandular tissues in the breast and therefore enhance the visibility of calcifications. In this study, a dual energy method based on analytical modeling was developed for the detection of minimum microcalcification thickness. To this aim, a modified radiographic X-ray unit was considered, in order to overcome the limited kVp range of mammographic units used in previous DE studies, combined with a high resolution CMOS sensor (pixel size of 22.5 μm) for improved resolution. Various filter materials were examined based on their K-absorption edge. Hydroxyapatite (HAp) was used to simulate microcalcifications. The contrast to noise ratio (CNRtc) of the subtracted images was calculated for both monoenergetic and polyenergetic X-ray beams. The optimum monoenergetic pair was 23/58 keV for the low and high energy, respectively, resulting in a minimum detectable microcalcification thickness of 100 μm. In the polyenergetic X-ray study, the optimal spectral combination was 40/70 kVp filtered with 100 μm cadmium and 1000 μm copper, respectively. In this case, the minimum detectable microcalcification thickness was 150 μm. The proposed dual energy method provides improved microcalcification detectability in breast imaging with mean glandular dose values within acceptable levels. PMID:26246848

  9. Monte Carlo derivation of filtered tungsten anode X-ray spectra for dose computation in digital mammography.

    PubMed

    Paixão, Lucas; Oliveira, Bruno Beraldo; Viloria, Carolina; de Oliveira, Marcio Alves; Teixeira, Maria Helena Araújo; Nogueira, Maria do Socorro

    2015-01-01

    Derive filtered tungsten X-ray spectra used in digital mammography systems by means of Monte Carlo simulations. Filtered spectra for rhodium filter were obtained for tube potentials between 26 and 32 kV. The half-value layer (HVL) of simulated filtered spectra were compared with those obtained experimentally with a solid state detector Unfors model 8202031-H Xi R/F & MAM Detector Platinum and 8201023-C Xi Base unit Platinum Plus w mAs in a Hologic Selenia Dimensions system using a direct radiography mode. Calculated HVL values showed good agreement as compared with those obtained experimentally. The greatest relative difference between the Monte Carlo calculated HVL values and experimental HVL values was 4%. The results show that the filtered tungsten anode X-ray spectra and the EGSnrc Monte Carlo code can be used for mean glandular dose determination in mammography.

  10. Monte Carlo derivation of filtered tungsten anode X-ray spectra for dose computation in digital mammography*

    PubMed Central

    Paixão, Lucas; Oliveira, Bruno Beraldo; Viloria, Carolina; de Oliveira, Marcio Alves; Teixeira, Maria Helena Araújo; Nogueira, Maria do Socorro

    2015-01-01

    Objective Derive filtered tungsten X-ray spectra used in digital mammography systems by means of Monte Carlo simulations. Materials and Methods Filtered spectra for rhodium filter were obtained for tube potentials between 26 and 32 kV. The half-value layer (HVL) of simulated filtered spectra were compared with those obtained experimentally with a solid state detector Unfors model 8202031-H Xi R/F & MAM Detector Platinum and 8201023-C Xi Base unit Platinum Plus w mAs in a Hologic Selenia Dimensions system using a direct radiography mode. Results Calculated HVL values showed good agreement as compared with those obtained experimentally. The greatest relative difference between the Monte Carlo calculated HVL values and experimental HVL values was 4%. Conclusion The results show that the filtered tungsten anode X-ray spectra and the EGSnrc Monte Carlo code can be used for mean glandular dose determination in mammography. PMID:26811553

  11. Morphologic expression of glandular differentiation in the epidermoid nasal carcinomas induced by phenylglycidyl ether inhalation.

    PubMed Central

    Lee, K. P.; Schneider, P. W.; Trochimowicz, H. J.

    1983-01-01

    Charles River-CD Sprague-Dawley rats in 3 equal groups of 100 males and 100 females each were exposed to 12, 1, and 0 ppm of phenylglycidyl ether vapor for 24 months. Nasal tumors were first detected after 621 days' exposure at 12 ppm with an incidence of 11% in males and 4.4% in females. No nasal tumors were found at 1 ppm in rats exposed for 24 months. The nasal tumors, mostly epidermoid carcinomas, were derived from the respiratory epithelium and nasal glands, both of which revealed squamous metaplasia or dysplasia in the anterior nasal cavity. Most nasal tumors were confined to the anterior nasal cavity and occasionally invaded the dorsonasal bones and posterior nasal cavity. The undifferentiated glandular cells appear to differentiate to neoplastic squamous cells, because the ultrastructure of epidermoid carcinoma revealed traits of glandular cell differentiation in the neoplastic squamous cells. The features of glandular cell differentiation in the neoplastic squamous cells were intercellular or intracellular glandular lumens, secretory vesicles, mucus droplets, and intermediate cells showing both glandular and squamous differentiation. Squamous cells in the well-differentiated epidermoid carcinomas revealed abundant tonofibrils, desmosomes, glycogen particulates, and interdigitated cytoplasmic processes. These markers of squamous-cell differentiation were markedly reduced in the undifferentiated epidermoid carcinomas. The spindle-cell squamous carcinoma showed both squamous and fibroblastic-like differentiations. Some spindle cells had only fibroblastic-like differentiation, suggesting spindle-cell metaplasia of the squamous cells. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 PMID:6846500

  12. Trichomes related to an unusual method of water retention and protection of the stem apex in an arid zone perennial species

    PubMed Central

    Lusa, Makeli Garibotti; Cardoso, Elaine Cristina; Machado, Silvia Rodrigues; Appezzato-da-Glória, Beatriz

    2015-01-01

    It is well known that trichomes protect plant organs, and several studies have investigated their role in the adaptation of plants to harsh environments. Recent studies have shown that the production of hydrophilic substances by glandular trichomes and the deposition of this secretion on young organs may facilitate water retention, thus preventing desiccation and favouring organ growth until the plant develops other protective mechanisms. Lychnophora diamantinana is a species endemic to the Brazilian ‘campos rupestres’ (rocky fields), a region characterized by intense solar radiation and water deficits. This study sought to investigate trichomes and the origin of the substances observed on the stem apices of L. diamantinana. Samples of stem apices, young and expanded leaves were studied using standard techniques, including light microscopy and scanning and transmission electron microscopy. Histochemical tests were used to identify the major groups of metabolites present in the trichomes and the hyaline material deposited on the apices. Non-glandular trichomes and glandular trichomes were observed. The material deposited on the stem apices was hyaline, highly hydrophilic and viscous. This hyaline material primarily consists of carbohydrates that result from the partial degradation of the cell wall of uniseriate trichomes. This degradation occurs at the same time that glandular trichomes secrete terpenoids, phenolic compounds and proteins. These results suggest that the non-glandular trichomes on the leaves of L. diamantinana help protect the young organ, particularly against desiccation, by deposition of highly hydrated substances on the apices. Furthermore, the secretion of glandular trichomes probably repels herbivore and pathogen attacks. PMID:25527474

  13. Mucinous expression in benign and neoplastic glandular lesions of the uterine cervix.

    PubMed

    Baker, Allyson C; Eltoum, Isam; Curry, Rebecca O; Stockard, Cecil R; Manne, Upender; Grizzle, William E; Chhieng, David

    2006-10-01

    Mucins are glycoproteins produced by both normal and neoplastic glandular epithelial cells including endocervix. To determine the expression of mucins in uterine cervical glandular lesions and whether mucin expression correlates with the nature and origin of the glandular lesions. Antibodies to MUC1, MUC2, MUC4, and MUC5AC were applied on 52 cases including 14 endocervical adenocarcinomas (including 4 adenosquamous carcinomas), 9 endometrial carcinomas (8 endometrioid adenocarcinomas and 1 adenosquamous carcinoma), 8 adenocarcinoma in situ (AIS), 2 glandular dysplasias, 6 tubal metaplasias, 10 microglandular hyperplasias, and 3 normal endocervix. The presence of any staining was considered positive. All benign endocervical epithelia, including tubal metaplasia and microglandular hyperplasia, expressed MUC1, MUC4, and MUC5AC but not MUC2. Almost all endocervical AIS and carcinomas and all endometrial adenocarcinomas expressed MUC1; the exceptions were 2 cases of endocervical adenocarcinoma and 1 case of adenosquamous carcinoma of the endocervix. MUC2 staining was noted in 25%, 40%, and 22% of AIS, endocervical adenocarcinomas, and endometrial adenocarcinomas, respectively. About 38% of AIS, 75% of endocervical adenocarcinomas, and 44% of endometrial adenocarcinomas expressed MUC4. Half of AIS, most of endocervical adenocarcinomas, and 22% of endometrial adenocarcinomas expressed MUC5AC. The difference in MUC4 and MUC5AC expression between benign endocervical lesions and AIS and the difference in MUC5AC expression between endocervical and endometrial neoplasms were statistically significant. Mucin expressions differed among benign endocervical lesions and AIS and among endocervical and endometrial malignancies. These results suggest that mucin staining may potentially be helpful in differentiating various uterine cervical glandular lesions.

  14. Plant Glandular Trichomes: Natural Cell Factories of High Biotechnological Interest1[OPEN

    PubMed Central

    2017-01-01

    Multicellular glandular trichomes are epidermal outgrowths characterized by the presence of a head made of cells that have the ability to secrete or store large quantities of specialized metabolites. Our understanding of the transcriptional control of glandular trichome initiation and development is still in its infancy. This review points to some central questions that need to be addressed to better understand how such specialized cell structures arise from the plant protodermis. A key and unique feature of glandular trichomes is their ability to synthesize and secrete large amounts, relative to their size, of a limited number of metabolites. As such, they qualify as true cell factories, making them interesting targets for metabolic engineering. In this review, recent advances regarding terpene metabolic engineering are highlighted, with a special focus on tobacco (Nicotiana tabacum). In particular, the choice of transcriptional promoters to drive transgene expression and the best ways to sink existing pools of terpene precursors are discussed. The bioavailability of existing pools of natural precursor molecules is a key parameter and is controlled by so-called cross talk between different biosynthetic pathways. As highlighted in this review, the exact nature and extent of such cross talk are only partially understood at present. In the future, awareness of, and detailed knowledge on, the biology of plant glandular trichome development and metabolism will generate new leads to tap the largely unexploited potential of glandular trichomes in plant resistance to pests and lead to the improved production of specialized metabolites with high industrial or pharmacological value. PMID:28724619

  15. Implementation of Synthesized Two-dimensional Mammography in a Population-based Digital Breast Tomosynthesis Screening Program

    PubMed Central

    Zuckerman, Samantha P.; Keller, Brad M.; Maidment, Andrew D. A.; Barufaldi, Bruno; Weinstein, Susan P.; Synnestvedt, Marie; McDonald, Elizabeth S.

    2016-01-01

    Purpose To evaluate the early implementation of synthesized two-dimensional (s2D) mammography in a population screened entirely with s2D and digital breast tomosynthesis (DBT) (referred to as s2D/DBT) and compare recall rates and cancer detection rates to historic outcomes of digital mammography combined with DBT (referred to as digital mammography/DBT) screening. Materials and Methods This was an institutional review board–approved and HIPAA-compliant retrospective interpretation of prospectively acquired data with waiver of informed consent. Compared were recall rates, biopsy rates, cancer detection rates, and radiation dose for 15 571 women screened with digital mammography/DBT from October 1, 2011, to February 28, 2013, and 5366 women screened with s2D/DBT from January 7, 2015, to June 30, 2015. Two-sample z tests of equal proportions were used to determine statistical significance. Results Recall rate for s2D/DBT versus digital mammography/DBT was 7.1% versus 8.8%, respectively (P < .001). Biopsy rate for s2D/DBT versus digital mammography/DBT decreased (1.3% vs 2.0%, respectively; P = .001). There was no significant difference in cancer detection rate for s2D/DBT versus digital mammography/DBT (5.03 of 1000 vs 5.45 of 1000, respectively; P = .72). The average glandular dose was 39% lower in s2D/DBT versus digital mammography/DBT (4.88 mGy vs 7.97 mGy, respectively; P < .001). Conclusion Screening with s2D/DBT in a large urban practice resulted in similar outcomes compared with digital mammography/DBT imaging. Screening with s2D/DBT allowed for the benefits of DBT with a decrease in radiation dose compared with digital mammography/DBT. © RSNA, 2016 An earlier incorrect version of this article appeared online. This article was corrected on August 11, 2016. PMID:27467468

  16. Breast dosimetry in clinical mammography

    NASA Astrophysics Data System (ADS)

    Benevides, Luis Alberto Do Rego

    The objective of this study was show that a clinical dosimetry protocol that utilizes a dosimetric breast phantom series based on population anthropometric measurements can reliably predict the average glandular dose (AGD) imparted to the patient during a routine screening mammogram. In the study, AGD was calculated using entrance skin exposure and dose conversion factors based on fibroglandular content, compressed breast thickness, mammography unit parameters and modifying parameters for homogeneous phantom (phantom factor), compressed breast lateral dimensions (volume factor) and anatomical features (anatomical factor). The protocol proposes the use of a fiber-optic coupled (FOCD) or Metal Oxide Semiconductor Field Effect Transistor (MOSFET) dosimeter to measure the entrance skin exposure at the time of the mammogram without interfering with diagnostic information of the mammogram. The study showed that FOCD had sensitivity with less than 7% energy dependence, linear in all tube current-time product stations, and was reproducible within 2%. FOCD was superior to MOSFET dosimeter in sensitivity, reusability, and reproducibility. The patient fibroglandular content was evaluated using a calibrated modified breast tissue equivalent homogeneous phantom series (BRTES-MOD) designed from anthropomorphic measurements of a screening mammography population and whose elemental composition was referenced to International Commission on Radiation Units and Measurements Report 44 tissues. The patient fibroglandular content, compressed breast thickness along with unit parameters and spectrum half-value layer were used to derive the currently used dose conversion factor (DgN). The study showed that the use of a homogeneous phantom, patient compressed breast lateral dimensions and patient anatomical features can affect AGD by as much as 12%, 3% and 1%, respectively. The protocol was found to be superior to existing methodologies. In addition, the study population anthropometric measurements enabled the development of analytical equations to calculate the whole breast area, estimate for the skin layer thickness and optimal location for automatic exposure control ionization chamber. The clinical dosimetry protocol developed in this study can reliably predict the AGD imparted to an individual patient during a routine screening mammogram.

  17. Sublethal responses of avian embryos exposed to polybrominated diphenyl ether flame retardants

    USGS Publications Warehouse

    Rattner, B.A.; McKernan, M.A.; Ottinger, M.

    2007-01-01

    Polybrominated diphenyl ethers PBDEs) have been detected in bird eggs worldwide, and despite increasing concentrations over the past 25 years, toxicological thresholds have yet to be established. We previously reported embryonic survival, and pipping and hatching success in chicken (Gallus gallus), mallard (Anas platyrhynchos) and American kestrel (Falco sparverius) embryos receiving 0.01-20 :g PBDE/g egg. Survival, pipping and hatching success were decreased in kestrels, suggesting that they are more sensitive to PBDEs than chickens and mallards. Adverse effects were detected in kestrels at levels (> 1 :g/g egg) believed to approach environmentally relevant PBDE concentrations. Polychlorinated biphenyl congener 126 (PCB 126) was used as a positive control (1000 pg/g egg) in this study, and survival endpoints in chicken and kestrel were decreased at this dose. Some PBDE and PCB congeners are structurally similar to thyroid hormones and have been demonstrated to affect thyroid homeostasis in laboratory rodents. In the present study, thyroid glands collected from day old hatchling chickens, mallards, and kestrels and were analyzed for thryoxine (T4) using a solid phase radioimmunoassay (DPC, Inc.) specifically validated for each of these species. Results indicated that thyroid gland T4 stores (total gland content and T4 /mg thyroid) in these species were relatively consistent and not significantly affected by PBDE exposure. In contrast, glandular T4 stores were significantly lower (P < 0.01) in PCB 126 treated kestrels. Decreases in circulating T4 levels in response to contaminants (e.g., PCBs, ammonium perchlorate) may lead to greater release of glandular T4 to maintain a euthyroid state, which could decrease thyroidal T4 stores. While PBDEs have been suggested to influence circulating T4 in kestrel fledglings (Fernie et al., 2005), it appears that glandular T4 was not affected in chicken, mallard or kestrel hatchlings exposed in ovo. Histopathological changes in liver, kidney and immune organs, bone length, and potential skeletal deformities are currently being examined.

  18. Glandular trichome density and essential oil composition in leaves and inflorescences of Lippia origanoides Kunth (Verbenaceae) in the Brazilian Cerrado.

    PubMed

    Tozin, Luiz R S; Marques, Marcia O M; Rodrigues, Tatiane M

    2015-01-01

    The essential oils from leaves and inflorescences of Lippia origanoides Kunth present aromatic and medicinal potential and have been used to treat several diseases, including melanoma. In Brazil, L. origanoides is commonly found in campo cerrado and cerrado stricto sensu, physiognomies featured mainly by the differential light conditions to which short and medium-sized plants are subjected. Our aim was to investigate the glandular trichome density and the yield and chemical composition of the essential oils in leaves and inflorescences of L. origanoides from campo cerrado and cerrado stricto sensu. For glandular density analysis, leaves and inflorescences were processed according to conventional techniques for scanning electron microscopy. The essential oils of leaves and inflorescences were obtained by hydrodistillation and identified with gas chromatography. Bracts and sepals showed the highest glandular density, followed by petals and leaves. The glandular density in the abaxial leaf surface was higher in individuals from the campo cerrado. In both populations the essential oil yield was higher in inflorescences than in leaves. The chemical composition of the essential oils varied among individuals from different areas and inside a same population. Our results demonstrated the chemical plasticity of L. origanoides suggesting the importance of monitoring its popular use.

  19. Breast-volume displacement using an extended glandular flap for small dense breasts.

    PubMed

    Ogawa, Tomoko; Hanamura, Noriko; Yamashita, Masako; Kimura, Hiroko; Kashikura, Yumi

    2011-01-01

    We defined the glandular flap including fat in the subclavicular area as an extended glandular flap, which has been used for breast-conserving reconstruction in the upper portion of the breast. Indication. The excision volume was 20% to 40% of the breast volume, and the breast density was dense. Surgical Technique. The upper edge of the breast at the subclavicular area was drawn in the standing position before surgery. After partial mastectomy, an extended glandular flap was made by freeing the breast from both the skin and the pectoralis fascia up to the preoperative marking in the subclavicular area. It is important to keep the perforators of the internal mammary artery and/or the branches of the lateral thoracic artery intact while making the flap. Results. Seventeen patients underwent remodeling using an extended glandular flap. The cosmetic results at 1 year after the operation: excellent in 11, good in 1, fair in 3, and poor in 2. All cases of unacceptable outcome except one were cases with complications, and more than 30% resection of moderate or large size breasts did not obtain an excellent result for long-term followup. Conclusion. This technique is useful for performing the breast-conserving reconstruction of small dense breasts.

  20. The relationship between organ dose and patient size in tube current modulated adult thoracic CT scans

    NASA Astrophysics Data System (ADS)

    Khatonabadi, Maryam; Zhang, Di; Yang, Jeffrey; DeMarco, John J.; Cagnon, Chris C.; McNitt-Gray, Michael F.

    2012-03-01

    Recently published AAPM Task Group 204 developed conversion coefficients that use scanner reported CTDIvol to estimate dose to the center of patient undergoing fixed tube current body exam. However, most performed CT exams use TCM to reduce dose to patients. Therefore, the purpose of this study was to investigate the correlation between organ dose and a variety of patient size metrics in adult chest CT scans that use tube current modulation (TCM). Monte Carlo simulations were performed for 32 voxelized models with contoured lungs and glandular breasts tissue, consisting of females and males. These simulations made use of patient's actual TCM data to estimate organ dose. Using image data, different size metrics were calculated, these measurements were all performed on one slice, at the level of patient's nipple. Estimated doses were normalized by scanner-reported CTDIvol and plotted versus different metrics. CTDIvol values were plotted versus different metrics to look at scanner's output versus size. The metrics performed similarly in terms of correlating with organ dose. Looking at each gender separately, for male models normalized lung dose showed a better linear correlation (r2=0.91) with effective diameter, while female models showed higher correlation (r2=0.59) with the anterior-posterior measurement. There was essentially no correlation observed between size and CTDIvol-normalized breast dose. However, a linear relationship was observed between absolute breast dose and size. Dose to lungs and breasts were consistently higher in females with similar size as males which could be due to shape and composition differences between genders in the thoracic region.

  1. Evaluation of low-energy contrast-enhanced spectral mammography images by comparing them to full-field digital mammography using EUREF image quality criteria.

    PubMed

    Lalji, U C; Jeukens, C R L P N; Houben, I; Nelemans, P J; van Engen, R E; van Wylick, E; Beets-Tan, R G H; Wildberger, J E; Paulis, L E; Lobbes, M B I

    2015-10-01

    Contrast-enhanced spectral mammography (CESM) examination results in a low-energy (LE) and contrast-enhanced image. The LE appears similar to a full-field digital mammogram (FFDM). Our aim was to evaluate LE CESM image quality by comparing it to FFDM using criteria defined by the European Reference Organization for Quality Assured Breast Screening and Diagnostic Services (EUREF). A total of 147 cases with both FFDM and LE images were independently scored by two experienced radiologists using these (20) EUREF criteria. Contrast detail measurements were performed using a dedicated phantom. Differences in image quality scores, average glandular dose, and contrast detail measurements between LE and FFDM were tested for statistical significance. No significant differences in image quality scores were observed between LE and FFDM images for 17 out of 20 criteria. LE scored significantly lower on one criterion regarding the sharpness of the pectoral muscle (p < 0.001), and significantly better on two criteria on the visualization of micro-calcifications (p = 0.02 and p = 0.034). Dose and contrast detail measurements did not reveal any physical explanation for these observed differences. Low-energy CESM images are non-inferior to FFDM images. From this perspective FFDM can be omitted in patients with an indication for CESM. • Low-energy CESM images are non-inferior to FFDM images. • Micro-calcifications are significantly more visible on LE CESM than on FFDM. • There is no physical explanation for this improved visibility of micro-calcifications. • There is no need for an extra FFDM when CESM is indicated.

  2. FFDM image quality assessment using computerized image texture analysis

    NASA Astrophysics Data System (ADS)

    Berger, Rachelle; Carton, Ann-Katherine; Maidment, Andrew D. A.; Kontos, Despina

    2010-04-01

    Quantitative measures of image quality (IQ) are routinely obtained during the evaluation of imaging systems. These measures, however, do not necessarily correlate with the IQ of the actual clinical images, which can also be affected by factors such as patient positioning. No quantitative method currently exists to evaluate clinical IQ. Therefore, we investigated the potential of using computerized image texture analysis to quantitatively assess IQ. Our hypothesis is that image texture features can be used to assess IQ as a measure of the image signal-to-noise ratio (SNR). To test feasibility, the "Rachel" anthropomorphic breast phantom (Model 169, Gammex RMI) was imaged with a Senographe 2000D FFDM system (GE Healthcare) using 220 unique exposure settings (target/filter, kVs, and mAs combinations). The mAs were varied from 10%-300% of that required for an average glandular dose (AGD) of 1.8 mGy. A 2.5cm2 retroareolar region of interest (ROI) was segmented from each image. The SNR was computed from the ROIs segmented from images linear with dose (i.e., raw images) after flat-field and off-set correction. Image texture features of skewness, coarseness, contrast, energy, homogeneity, and fractal dimension were computed from the Premium ViewTM postprocessed image ROIs. Multiple linear regression demonstrated a strong association between the computed image texture features and SNR (R2=0.92, p<=0.001). When including kV, target and filter as additional predictor variables, a stronger association with SNR was observed (R2=0.95, p<=0.001). The strong associations indicate that computerized image texture analysis can be used to measure image SNR and potentially aid in automating IQ assessment as a component of the clinical workflow. Further work is underway to validate our findings in larger clinical datasets.

  3. Metastatic Urothelial Carcinoma with Glandular Differentiation That Confirmed the Response by Autopsy Specimen to Second-Line mFOLFOX6 (Fluorouracil, Oxaliplatin, and Leucovorin) plus Bevacizumab Chemotherapy

    PubMed Central

    Naiki, Taku; Etani, Toshiki; Naiki-Ito, Aya; Fujii, Kana; Ando, Ryosuke; Iida, Keitaro; Nagai, Takashi; Sugiyama, Yosuke; Nakagawa, Motoo; Kawai, Noriyasu; Yasui, Takahiro

    2017-01-01

    The prognostic significance of glandular differentiation in urothelial carcinoma (UC) is controversial, and thus far there is no established treatment strategy against metastasis of glandular component. We describe here a case of metastatic UC with glandular differentiation that had histological disappearance of adenocarcinoma components at autopsy after sequential chemotherapy with S-1 and cisplatin (CDDP) and with mFOLFOX6 (fluorouracil, oxaliplatin, and leucovorin) plus bevacizumab (mFOLFOX6+Bev). A 62-year-old Asian male was diagnosed with invasive UC with glandular differentiation (T2N0M0) by radical cystectomy and ileal conduit, and careful follow-up observation was made. Eight years after radical operation, peritoneal metastases occurred, and a biopsy specimen using colon fiber revealed high-grade adenocarcinomas with an immunohistochemical profile that included positivity for cytokeratin 7 (CK7) and negativity for cytokeratin 20 (CK20) and uroplakin, which was identical to the radical cystectomy specimen. Thus, he received combination chemotherapy consisting of S-1 and CDDP; however, the peritoneal metastasis worsened after 2 cycles. Therefore, second-line mFOLFOX6+Bev chemotherapy was performed for a total of 5 courses. In spite of this, the patient died, and the final diagnosis by autopsy was multiple metastases of infiltrating pure UC to the lung, bone, and peritoneum. Interestingly, there were no pathological findings of adenocarcinoma, and the immunohistochemical profile of the metastatic lesions was identical to that of the previous specimens from the bladder and colon. This suggests that sequential chemotherapy of S-1 and CDDP and second-line mFOLFOX6+Bev might be a feasible option in metastatic UC with glandular differentiation. PMID:29515396

  4. Atypical glandular cells in cervical smears: histological correlation and a suggested plan of management based on age of the patient in a low-resource setting.

    PubMed

    Adhya, A K; Mahesha, V; Srinivasan, R; Nijhawan, R; Rajwanshi, A; Suri, V; Dhaliwal, L K

    2009-12-01

    To perform an audit of all smears reported as atypical glandular cells (AGC) using the Bethesda system (TBS) 2001. A total of 18 376 cervical smears were screened from January 2005 to June 2007, of which 65 cases were reported as AGC. Follow-up histology was available in 31 cases (47.7%), in whom a detailed cytological/histological correlation was carried out. AGC constituted 0.35% of all Pap smears. Follow-up histology was normal or benign in 20 cases, whereas a squamous or glandular abnormality was seen in 11 cases. Squamous abnormalities included one case each of cervical intraepithelial neoplasia (CIN)1, CIN2 and CIN3 and five cases of squamous cell carcinoma. All glandular epithelial abnormalities were endometrial in origin and included two endometrial adenocarcinomas and one uterine serous carcinoma. Neither in situ nor invasive adenocarcinoma of the endocervix was observed. Review of smears and reclassification as AGC, not otherwise specified and favour neoplasia revealed a higher proportion of abnormality in the latter group, reaffirming the utility of subtyping. The median age of women with AGC was 41 years. The outcome was analysed with respect to the median age. In women aged equal or more than 40 years, AGC reflected a high-grade squamous or glandular epithelial abnormality in 50% of cases compared with none in those less than 40 years old (P = 0.010). The age of the woman as well as the subtype of atypical glandular cells influences outcome and hence must be taken into consideration while formulating an acceptable management strategy in these women in a low-resource setting.

  5. Low-Dose Contrast-Enhanced Breast CT Using Spectral Shaping Filters: An Experimental Study.

    PubMed

    Makeev, Andrey; Glick, Stephen J

    2017-12-01

    Iodinated contrast-enhanced X-ray imaging of the breast has been studied with various modalities, including full-field digital mammography (FFDM), digital breast tomosynthesis (DBT), and dedicated breast CT. Contrast imaging with breast CT has a number of advantages over FFDM and DBT, including the lack of breast compression, and generation of fully isotropic 3-D reconstructions. Nonetheless, for breast CT to be considered as a viable tool for routine clinical use, it would be desirable to reduce radiation dose. One approach for dose reduction in breast CT is spectral shaping using X-ray filters. In this paper, two high atomic number filter materials are studied, namely, gadolinium (Gd) and erbium (Er), and compared with Al and Cu filters currently used in breast CT systems. Task-based performance is assessed by imaging a cylindrical poly(methyl methacrylate) phantom with iodine inserts on a benchtop breast CT system that emulates clinical breast CT. To evaluate detectability, a channelized hoteling observer (CHO) is used with sums of Laguerre-Gauss channels. It was observed that spectral shaping using Er and Gd filters substantially increased the dose efficiency (defined as signal-to-noise ratio of the CHO divided by mean glandular dose) as compared with kilovolt peak and filter settings used in commercial and prototype breast CT systems. These experimental phantom study results are encouraging for reducing dose of breast CT, however, further evaluation involving patients is needed.

  6. Glandular Lesions of the Cervix in Clinical Practice: A Cytology, Histology, and Human Papillomavirus Correlation Study From 2 Institutions.

    PubMed

    Miller, Ross A; Mody, Dina R; Tams, Kimberlee C; Thrall, Michael J

    2015-11-01

    The Papanicolaou (Pap) test has indisputably decreased cervical cancer mortality, as rates have declined by up to 80% in the United States since its implementation. However, the Pap test is considered less sensitive for detecting glandular lesions than for detecting those of squamous origin. Some studies have even suggested an increasing incidence of cervical adenocarcinoma, which may be a consequence of a relatively reduced ability to detect glandular lesions with cervical cancer screening techniques. To evaluate the detection rate of glandular lesions with screening techniques currently used for cervical cancer screening and to provide insight as to which techniques are most efficacious in our study population. We retrospectively reviewed any available cytology, human papillomavirus (HPV), and histologic malignancy data in patients diagnosed with adenocarcinoma in situ and adenocarcinoma from 2 geographically and socioeconomically disparate hospital systems. Identified patients having had a negative/unsatisfactory Pap test within 5 years of adenocarcinoma in situ or adenocarcinoma tissue diagnosis were considered Pap test screening failures. Patients with negative HPV tests on cytology samples were considered HPV screening failures. One hundred thirty cases were identified (age range, 22-93 years); 39 (30%) had no Pap history in our files. Eight of 91 remaining cases (8.8%) were screening failures. The detected sensitivity for identifying adenocarcinoma in situ/adenocarcinoma in this study was 91.2% by cytology alone and 92.3% when incorporating HPV testing. The most common cytologic diagnosis was atypical glandular cells (25 cases), and those diagnosed with adenocarcinoma were 7.4 years older than those diagnosed with adenocarcinoma in situ (50.3 versus 42.9 years). Nine of 24 HPV-tested cases (37.5%) were called atypical squamous cell of undetermined significance on cytology. Our results highlight the importance of combined Pap and HPV cotesting. Although the number of cases identified is relatively small, our data suggest screening for squamous lesions facilitates the recognition of glandular lesions in the cervix. Additionally, increased use of combined Pap and HPV cotesting may decrease detection failure rates with regard to glandular lesions.

  7. The role of peritoneal washings in the diagnosis of endometriosis.

    PubMed

    Cantley, Richard L; Yoxtheimer, Lorene; Molnar, Stacy

    2018-05-01

    Endometriosis, the presence of endometrial tissue outside the uterine corpus, is a common finding in reproductive age women. It is classically diagnosed based on the presence of at least two of the following elements: endometrial glands, endometrial stroma, and hemosiderin-laden macrophages (HLMs). Although a common finding in surgical pathology specimens at the time of gynecologic surgery, there is little literature on the role of pelvic washings in diagnosing endometriosis. Our study aimed to examine the characteristics of endometriosis in pelvic washings at the time of gynecologic surgery. We report nine cases of endometriosis diagnosed on pelvic washing. Two had a reported history of endometriosis. Four had endometriosis on the concurrent surgical pathology specimen. Liquid-based cytology was diagnostic of endometriosis in seven patients, including five with glandular cells and HLMs and two with glandular cells, HLMs, and endometrial stromal cells. Cell block was diagnostic of endometriosis in eight patients, including four cases with intact fragments of endometrial glands and stroma. Three cases showed glandular cells and HLMs, while one showed separate fragments of glandular cells and stromal cells. Pelvic washings increased the diagnostic yield for endometriosis at the time of gynecologic surgery, as only four out of nine cases had endometriosis diagnosed on surgical pathology. Cell block in particular aids in the diagnosis, since intact glandular and stromal fragments frequently can be identified. © 2018 Wiley Periodicals, Inc.

  8. Monte Carlo simulation studies for the determination of microcalcification thickness and glandular ratio through dual-energy mammography

    NASA Astrophysics Data System (ADS)

    Del Lama, L. S.; Godeli, J.; Poletti, M. E.

    2017-08-01

    The majority of breast carcinomas can be associated to the presence of calcifications before the development of a mass. However, the overlapping tissues can obscure the visualization of microcalcification clusters due to the reduced contrast-noise ratio (CNR). In order to overcome this complication, one potential solution is the use of the dual-energy (DE) technique, in which two different images are acquired at low (LE) and high (HE) energies or kVp to highlight specific lesions or cancel out tissue background. In this work, the DE features were computationally studied considering simulated acquisitions from a modified PENELOPE Monte Carlo code. The employed irradiation geometry considered typical distances used in digital mammography, a CsI detection system and an updated breast model composed of skin, microcalcifications and glandular and adipose tissues. The breast thickness ranged from 2 to 6 cm with glandularities of 25%, 50% and 75%, where microcalcifications with dimensions from 100 up to 600 μm were positioned. In general, results pointed an efficiency index better than 87% for the microcalcification thicknesses and better than 95% for the glandular ratio. The simulations evaluated in this work can be used to optimize the elements from the DE imaging chain, in order to become a complementary tool for the conventional single-exposure images, especially for the visualization and estimation of calcification thicknesses and glandular ratios.

  9. Cyclin d1 expression in odontogenic cysts.

    PubMed

    Taghavi, Nasim; Modabbernia, Shirin; Akbarzadeh, Alireza; Sajjadi, Samad

    2013-01-01

    In the present study expression of cyclin D1 in the epithelial lining of odontogenic keratocyst, radicular cyst, dentigerous cyst and glandular odontogenic cyst was investigated to compare proliferative activity in these lesions. Immunohistochemical staining of cyclin D1 on formalin-fixed, paraffin-embedded tissue sections of odontogenic keratocysts (n=23), dentigerous cysts (n=20), radicular cysts (n=20) and glandular odontogenic cysts (n=5) was performed by standard EnVision method. Then, slides were studied to evaluate the following parameters in epithelial lining of cysts: expression, expression pattern, staining intensity and localization of expression. The data analysis showed statistically significant difference in cyclin D1 expression in studied groups (p < 0.001). Assessment of staining intensity and staining pattern showed more strong intensity and focally pattern in odontogenic keratocysts, but difference was not statistically significant among groups respectively (p=0.204, 0.469). Considering expression localization, cyclin D1 positive cells in odontogenic keratocysts and dentigerous cysts were frequently confined in parabasal layer, different from radicular cysts and glandular odontogenic cysts. The difference was statistically significant (p < 0.01). Findings showed higher expression of cyclin D1 in parabasal layer of odontogenic keratocyst and the entire cystic epithelium of glandular odontogenic cysts comparing to dentigerous cysts and radicular cysts, implying the possible role of G1-S cell cycle phase disturbances in the aggressiveness of odontogenic keratocyst and glandular odontogenic cyst.

  10. [Mastopexy in Massive Weight Loss Patients - Extended Ribeiro Technique and Usage of the Lateral Intercostal Artery Perforator Flap (LICAP Flap) for Autoaugmentation].

    PubMed

    Wolter, Andreas; Scholz, Till; Pluto, Naja; Diedrichson, Jens; Arens-Landwehr, Andreas; Liebau, Jutta

    2017-12-01

     Mastopexy in massive weight loss patients is challenging. The breast mound is often unstable and deflated, with a loose inelastic skin envelope. It has become apparent that mammaplasty techniques in these cases should rely more on glandular recontouring rather than on the skin envelope for shaping. Published methods include plication, suspension and autoaugmentation. The residual local tissue (glandular breast tissue, fat tissue, dermoglandular fat flap) is utilised to its full extent in order to reshape a form-stable breast with full upper pole projection. The evolution of a technique is presented.  In this study we retrospectively analysed 68 massive weight loss patients who underwent an extended Ribeiro technique with a superomedial pedicle mastopexy and suspension by an inferior dermoglandular flap. The current procedure involves incorporating the lateral intercostal artery perforator flap (LICAP flap) and medial breast pillar additionally to the inferior dermoglandular Ribeiro flap. This essentially autoaugments the upper pole by creating an "autoprosthesis", narrows the widened breast, and redefines the inframammary fold. The outcome parameters complication rate, patient satisfaction with the aesthetic result, nipple sensibility and surgical revision rate were obtained.  From 01/2011 to 12/2016, we performed 136 autoaugmentation mastopexies. The average age was 41.2 years, average body mass index (BMI) was 27,1 kg/m 2 , average weight loss was 54.3 kg, average sternal notch-NAC distance was 32.3 cm, average operation time was 109 minutes. In 12 breasts, a free-nipple graft was necessary. The complication rate was 5.1 %, surgical revision rate was 17.6 %. 95 % of the patients were "very satisfied" or "satisfied" with the aesthetic result. Nipple sensibility was rated as "very good" or "good" by 85 % of patients.  Modification of the Ribeiro technique by using the medial and lateral breast pillar (LICAP flap) allows autoaugmentation of the upper pole. Parenchymal shaping through plication and suspension of the breast mound should improve breast shape over time, with the aim of reducing the incidence of recurrent ptosis. The presented technique is a reproducible and reliable method with a low complication rate. Georg Thieme Verlag KG Stuttgart · New York.

  11. A stepwedge-based method for measuring breast density: observer variability and comparison with human reading

    NASA Astrophysics Data System (ADS)

    Diffey, Jenny; Berks, Michael; Hufton, Alan; Chung, Camilla; Verow, Rosanne; Morrison, Joanna; Wilson, Mary; Boggis, Caroline; Morris, Julie; Maxwell, Anthony; Astley, Susan

    2010-04-01

    Breast density is positively linked to the risk of developing breast cancer. We have developed a semi-automated, stepwedge-based method that has been applied to the mammograms of 1,289 women in the UK breast screening programme to measure breast density by volume and area. 116 images were analysed by three independent operators to assess inter-observer variability; 24 of these were analysed on 10 separate occasions by the same operator to determine intra-observer variability. 168 separate images were analysed using the stepwedge method and by two radiologists who independently estimated percentage breast density by area. There was little intra-observer variability in the stepwedge method (average coefficients of variation 3.49% - 5.73%). There were significant differences in the volumes of glandular tissue obtained by the three operators. This was attributed to variations in the operators' definition of the breast edge. For fatty and dense breasts, there was good correlation between breast density assessed by the stepwedge method and the radiologists. This was also observed between radiologists, despite significant inter-observer variation. Based on analysis of thresholds used in the stepwedge method, radiologists' definition of a dense pixel is one in which the percentage of glandular tissue is between 10 and 20% of the total thickness of tissue.

  12. Evaluation of Pepsinogen I as a Biomarker of Drug-induced Gastric Mucosal Injury in Cynomolgus Monkeys.

    PubMed

    Ennulat, Daniela; Lynch, Karen M; Kimbrough, Carie L; Mirabile, Rosanna C; Rehm, Sabine

    2017-02-01

    Gastric mucosal injury is frequently observed in nonclinical studies of nonhuman primates. Because microscopic evaluation of stomach is generally a terminal procedure, our objective was to determine whether serum pepsinogen I (PG I) could serve as a noninvasive biomarker for detection of gastric mucosal injury in monkey. Serum PG I was measured using a commercial human immunoassay in cynomolgus monkeys ( n = 166) prior to dosing and/or terminally in 11 studies of up to 1 month duration. Mean ( SD) PG I values (ug/L) for monkeys with ( n = 59) and without ( n = 100) gastric mucosal degeneration were 101 (215) and 28 (12.6), respectively. For monkeys with baseline and terminal PG I data, mean ( SD) fold change (ratio of terminal to baseline PG I) for monkeys with ( n = 57) and without ( n = 76) glandular degeneration were 4.1 (11.3) and 1 (0.28). Receiver operating characteristic area under the curve (AUC) data demonstrated moderate diagnostic accuracy for serum PG I for glandular degeneration, AUC ( SE) 0.789 (0.04), with improved diagnostic accuracy as a fold change of baseline, AUC ( SE) 0.816 (0.04), consistent with the large interindividual but low intraindividual variability of serum PG I values in control monkeys. These data demonstrate that serum PG I is a useful biomarker of drug-induced gastric mucosal injury in the cynomolgus monkey.

  13. Is chronic detergent ingestion harmful to the gut?

    PubMed Central

    Mercurius-Taylor, L A; Jayaraj, A P; Clark, C G

    1984-01-01

    Synthetic detergents are used in large quantities as household and industrial cleaners. Because of the common practice of leaving dishes washed in detergent solutions to dry without rinsing these compounds are ingested. We have calculated that an adult takes in about 1 mg/kg detergent a day and babies can be administered between seven and 10 mg/kg a day. Rats were fed a dose of 100 mg/kg a day in a pilot experiment and gross abnormalities were found in the gastrointestinal tract, the most striking being subtotal villous atrophy of the small bowel mucosa and glandular atrophy in the colon. These changes were not reversible 12 weeks after cessation of detergent administration. Images PMID:6722057

  14. Efficient iterative image reconstruction algorithm for dedicated breast CT

    NASA Astrophysics Data System (ADS)

    Antropova, Natalia; Sanchez, Adrian; Reiser, Ingrid S.; Sidky, Emil Y.; Boone, John; Pan, Xiaochuan

    2016-03-01

    Dedicated breast computed tomography (bCT) is currently being studied as a potential screening method for breast cancer. The X-ray exposure is set low to achieve an average glandular dose comparable to that of mammography, yielding projection data that contains high levels of noise. Iterative image reconstruction (IIR) algorithms may be well-suited for the system since they potentially reduce the effects of noise in the reconstructed images. However, IIR outcomes can be difficult to control since the algorithm parameters do not directly correspond to the image properties. Also, IIR algorithms are computationally demanding and have optimal parameter settings that depend on the size and shape of the breast and positioning of the patient. In this work, we design an efficient IIR algorithm with meaningful parameter specifications and that can be used on a large, diverse sample of bCT cases. The flexibility and efficiency of this method comes from having the final image produced by a linear combination of two separately reconstructed images - one containing gray level information and the other with enhanced high frequency components. Both of the images result from few iterations of separate IIR algorithms. The proposed algorithm depends on two parameters both of which have a well-defined impact on image quality. The algorithm is applied to numerous bCT cases from a dedicated bCT prototype system developed at University of California, Davis.

  15. The Characteristics and Short-Term Surgical Outcomes of Adolescent Gynecomastia.

    PubMed

    Choi, Byung Seo; Lee, Sung Ryul; Byun, Geon Young; Hwang, Seong Bae; Koo, Bum Hwan

    2017-10-01

    Most adolescent gynecomastia is resolved spontaneously in 3 years. But, persistent gynecomastia could have a negative influence on psychoemotional development on adolescence. The purpose of this study is to report the characteristics of adolescent gynecomastia patients who received the surgeries, and discuss the short-term surgical outcomes. Of the 1454 patients who underwent gynecomastia surgery at Damsoyu hospital from January 2014 to May 2016, 71 were adolescents. Subcutaneous mastectomy with liposuction was performed for adolescent patients who had gynecomastia for more than 3 years and showed psychosocial distress. Demographic and outcome variables were retrospectively analyzed. The mean age was 17.5 ± 0.77 years old. All gynecomastia cases were bilateral. Simon's grade IIa (35 patients, 49.3%) was the most common, and grade III was not observed. Fifty-one patients (71.8%) were classified as having a glandular-type breast component. Fourteen patients (19.7%) had complications, but only 3 cases (4.2%) required revision. Most of the patients (70 patients, 98.6%) were satisfied with the esthetic results, and the average 5-point Likert score was 4.85 ± 0.40. Recurrence was not observed. As the Simon's grade increased from I to IIA, a higher BMI, larger amounts of breast tissue, and longer operation times were observed. Gynecomastia that did not regress spontaneously was mostly the glandular type, so not only liposuction but also surgical removal of glandular tissue is necessary. Surgical treatment, selectively performed in patients who have had gynecomastia for 3 years, and have experienced psychosocial distress, could be an acceptable treatment for adolescent gynecomastia. This journal requires that authors assign a level of evidence to each article. For a full description of these evidence-based medicine ratings, please refer to the table of contents or the online instructions to authors www.springer.com/00266 .

  16. Sweat Gland Progenitors in Development, Homeostasis, and Wound Repair

    PubMed Central

    Lu, Catherine; Fuchs, Elaine

    2014-01-01

    The human body is covered with several million sweat glands. These tiny coiled tubular skin appendages produce the sweat that is our primary source of cooling and hydration of the skin. Numerous studies have been published on their morphology and physiology. Until recently, however, little was known about how glandular skin maintains homeostasis and repairs itself after tissue injury. Here, we provide a brief overview of sweat gland biology, including newly identified reservoirs of stem cells in glandular skin and their activation in response to different types of injuries. Finally, we discuss how the genetics and biology of glandular skin has advanced our knowledge of human disorders associated with altered sweat gland activity. PMID:24492848

  17. Expression of p16Ink4a in mixed squamous cell and glandular papilloma of the lung.

    PubMed

    Miyoshi, Ryo; Menju, Toshi; Yoshizawa, Akihiko; Date, Hiroshi

    2017-06-01

    Mixed squamous cell and glandular papilloma (mixed papilloma) of the lung is an extremely rare neoplasm, with only 21 cases reported in the English literature. Although the expression of p16 Ink4a has been analyzed in only two cases of mixed papilloma, they were negative for p16 Ink4a . Therefore, the significance of p16 Ink4a overexpression in mixed papilloma remains unclear. This is the first case of mixed papilloma with positive p16 Ink4a expression in a 72-year-old male smoker. The 20 mm sized tumor was histologically diagnosed as mixed papilloma following right upper lobectomy. Immunohistochemically, cytokeratin 5 and p40 positivity was predominant in basal cells of the glandular component and squamous cells, while thyroid transcription factor-1, p53, and Ki-67 were focally positive. Both glandular and squamous components were diffusely positive for p16 Ink4a . This finding could be important to clarify the pathogenesis and biology of mixed papilloma. © 2017 Japanese Society of Pathology and John Wiley & Sons Australia, Ltd.

  18. Carcinogenicity of 4-methoxyphenol and 4-methylcatechol in F344 rats.

    PubMed

    Asakawa, E; Hirose, M; Hagiwara, A; Takahashi, S; Ito, N

    1994-01-02

    The carcinogenic potentials of 4-methoxyphenol (4-MP) and 4-methylcatechol (4-MC), phenolic compounds which are structurally similar to the known forestomach carcinogen BHA and the glandular stomach carcinogen catechol respectively, and cause considerably enhanced cell proliferation and cytotoxicities in rat forestomach and/or glandular stomach epithelium, were examined in male and female F344 rats. Groups of 30 male and female animals were administered diets containing 2% 4-MP or 2% 4-MC for 104 weeks. Histopathological findings in the 4-MP case included atypical hyperplasias (male, 67%, female, 37%), papillomas (50%, 23%) and squamous-cell carcinomas (77%, 20%) in the forestomach. 4-MC induced forestomach papillomas (70%, 93%) and squamous-cell carcinomas (53%, 37%), also glandular stomach submucosal hyperplasias (90%, 93%), adenomas (100%, 100%) and adenocarcinomas (57%, 47%), with ulceration or erosion. The degree of differentiation of the squamous-cell carcinomas induced by 4-MP was less than with 4-MC. The present study demonstrated unequivocal forestomach carcinogenicity for 4-MP and forestomach and glandular stomach carcinogenicity for 4-MC, with cytotoxicity and cell proliferation both appearing as important factors for these non-genotoxic carcinogens.

  19. CINtec PLUS immunocytochemistry as a tool for the cytologic diagnosis of glandular lesions of the cervix uteri.

    PubMed

    Ravarino, Alberto; Nemolato, Sonia; Macciocu, Elena; Fraschini, Matteo; Senes, Giancarlo; Faa, Gavino; Negri, Giovanni

    2012-11-01

    Cytologic findings of glandular lesions of the cervix uteri are often difficult to evaluate. We studied the usefulness of CINtec PLUS p16/Ki-67 double stain (mtm laboratories, Heidelberg, Germany) for the diagnosis of glandular lesions. The study included 47 abnormal results on liquid-based cytologic tests with a subsequent histologic diagnosis of adenocarcinoma in situ or with early invasion, and 16 samples with negative results on follow-up. All samples were stained with CINtec PLUS p16/Ki-67 double stain. Of the neoplastic samples, 7 were excluded because of insufficient residual cellularity or loss of neoplastic cells. Of the samples that were adequate, 92.5% were stained with CINtec PLUS, whereas 7.5% were judged inconclusive. All inconclusive cases were at least 3 years old. Of the 16 negative samples, 15 (93.8%) stained negative and only 1 (6.2%) showed several positive clusters of cells. Our study shows that CINtec PLUS is a robust and useful tool for the diagnosis of glandular lesions of the cervix uteri.

  20. Characterization of scatter in digital mammography from use of Monte Carlo simulations and comparison to physical measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leon, Stephanie M., E-mail: Stephanie.Leon@uth.tmc.edu; Wagner, Louis K.; Brateman, Libby F.

    2014-11-01

    Purpose: Monte Carlo simulations were performed with the goal of verifying previously published physical measurements characterizing scatter as a function of apparent thickness. A secondary goal was to provide a way of determining what effect tissue glandularity might have on the scatter characteristics of breast tissue. The overall reason for characterizing mammography scatter in this research is the application of these data to an image processing-based scatter-correction program. Methods: MCNPX was used to simulate scatter from an infinitesimal pencil beam using typical mammography geometries and techniques. The spreading of the pencil beam was characterized by two parameters: mean radial extentmore » (MRE) and scatter fraction (SF). The SF and MRE were found as functions of target, filter, tube potential, phantom thickness, and the presence or absence of a grid. The SF was determined by separating scatter and primary by the angle of incidence on the detector, then finding the ratio of the measured scatter to the total number of detected events. The accuracy of the MRE was determined by placing ring-shaped tallies around the impulse and fitting those data to the point-spread function (PSF) equation using the value for MRE derived from the physical measurements. The goodness-of-fit was determined for each data set as a means of assessing the accuracy of the physical MRE data. The effect of breast glandularity on the SF, MRE, and apparent tissue thickness was also considered for a limited number of techniques. Results: The agreement between the physical measurements and the results of the Monte Carlo simulations was assessed. With a grid, the SFs ranged from 0.065 to 0.089, with absolute differences between the measured and simulated SFs averaging 0.02. Without a grid, the range was 0.28–0.51, with absolute differences averaging −0.01. The goodness-of-fit values comparing the Monte Carlo data to the PSF from the physical measurements ranged from 0.96 to 1.00 with a grid and 0.65 to 0.86 without a grid. Analysis of the data suggested that the nongrid data could be better described by a biexponential function than the single exponential used here. The simulations assessing the effect of breast composition on SF and MRE showed only a slight impact on these quantities. When compared to a mix of 50% glandular/50% adipose tissue, the impact of substituting adipose or glandular breast compositions on the apparent thickness of the tissue was about 5%. Conclusions: The findings show agreement between the physical measurements published previously and the Monte Carlo simulations presented here; the resulting data can therefore be used more confidently for an application such as image processing-based scatter correction. The findings also suggest that breast composition does not have a major impact on the scatter characteristics of breast tissue. Application of the scatter data to the development of a scatter-correction software program can be simplified by ignoring the variations in density among breast tissues.« less

  1. [Minimally invasive surgical therapy of gynecomastia: liposuction and exeresis technique].

    PubMed

    Voigt, M; Walgenbach, K J; Andree, C; Bannasch, H; Looden, Z; Stark, G B

    2001-10-01

    A number of techniques are available for the correction of gynecomastia. Nonscarring sparing methods are preferred, and the minimally invasive technique is to use liposuction for the gland and the fatty tissue exclusively. In this retrospective study we present our experience with a combination of liposuction and subsequent resection of the remaining gland. Sixty-two patients (112 breasts) were surgically treated for gynecomastia from January 1996 and September 2000. From 1996 to 1997 all patients suffering from gynecomastia grade Simon I-II were treated by the method described by Rosenberg and Stark, which is exclusively suction of the fatty and glandular tissue. In a retrospective chart study a high recurrence rate was found in these patients. Subsequently we changed our technique to liposuction of the fatty tissue followed by sharp excision of the glandular tissue through the incision made for the liposuction cannula in the submammary fold. Suction alone was not sufficient to remove the glandular tissue; the rate of recurrence after suction was 35%. When sharp resection of the glandular tissue was carried out after the liposuction the recurrence rate dropped to under 10%. In total our complication rate was 50% including minor sequelae. The most frequent complication was unacceptable scarring of the nipple-areola complex. Hypesthesia of the nipple-areola occurred in 13.4% of the patients. The combination of liposuction and resection of the glandular tissue is a minimally invasive correction that can be used in all cases of gynecomastia grade Simon I-II.

  2. Differential microRNA Analysis of Glandular Trichomes and Young Leaves in Xanthium strumarium L. Reveals Their Putative Roles in Regulating Terpenoid Biosynthesis.

    PubMed

    Fan, Rongyan; Li, Yuanjun; Li, Changfu; Zhang, Yansheng

    2015-01-01

    The medicinal plant Xanthium strumarium L. (X. strumarium) is covered with glandular trichomes, which are the sites for synthesizing pharmacologically active terpenoids such as xanthatin. MicroRNAs (miRNAs) are a class of 21-24 nucleotide (nt) non-coding RNAs, most of which are identified as regulators of plant growth development. Identification of miRNAs involved in the biosynthesis of plant secondary metabolites remains limited. In this study, high-throughput Illumina sequencing, combined with target gene prediction, was performed to discover novel and conserved miRNAs with potential roles in regulating terpenoid biosynthesis in X. strumarium glandular trichomes. Two small RNA libraries from leaves and glandular trichomes of X. strumarium were established. In total, 1,185 conserved miRNAs and 37 novel miRNAs were identified, with 494 conserved miRNAs and 18 novel miRNAs being differentially expressed between the two tissue sources. Based on the X. strumarium transcriptome data that we recently constructed, 3,307 annotated mRNA transcripts were identified as putative targets of the differentially expressed miRNAs. KEGG (Kyoto Encyclopedia of Genes and Genomes) pathway analysis suggested that some of the differentially expressed miRNAs, including miR6435, miR5021 and miR1134, might be involved in terpenoid biosynthesis in the X. strumarium glandular trichomes. This study provides the first comprehensive analysis of miRNAs in X. strumarium, which forms the basis for further understanding of miRNA-based regulation on terpenoid biosynthesis.

  3. Estimation of effective x-ray tissue attenuation differences for volumetric breast density measurement

    NASA Astrophysics Data System (ADS)

    Chen, Biao; Ruth, Chris; Jing, Zhenxue; Ren, Baorui; Smith, Andrew; Kshirsagar, Ashwini

    2014-03-01

    Breast density has been identified to be a risk factor of developing breast cancer and an indicator of lesion diagnostic obstruction due to masking effect. Volumetric density measurement evaluates fibro-glandular volume, breast volume, and breast volume density measures that have potential advantages over area density measurement in risk assessment. One class of volume density computing methods is based on the finding of the relative fibro-glandular tissue attenuation with regards to the reference fat tissue, and the estimation of the effective x-ray tissue attenuation differences between the fibro-glandular and fat tissue is key to volumetric breast density computing. We have modeled the effective attenuation difference as a function of actual x-ray skin entrance spectrum, breast thickness, fibro-glandular tissue thickness distribution, and detector efficiency. Compared to other approaches, our method has threefold advantages: (1) avoids the system calibration-based creation of effective attenuation differences which may introduce tedious calibrations for each imaging system and may not reflect the spectrum change and scatter induced overestimation or underestimation of breast density; (2) obtains the system specific separate and differential attenuation values of fibroglandular and fat for each mammographic image; and (3) further reduces the impact of breast thickness accuracy to volumetric breast density. A quantitative breast volume phantom with a set of equivalent fibro-glandular thicknesses has been used to evaluate the volume breast density measurement with the proposed method. The experimental results have shown that the method has significantly improved the accuracy of estimating breast density.

  4. Why prostate tumour delineation based on apparent diffusion coefficient is challenging: an exploration of the tissue microanatomy.

    PubMed

    Borren, Alie; Moman, Maaike R; Groenendaal, Greetje; Boeken Kruger, Arto E; van Diest, Paul J; van der Groep, Petra; van der Heide, Uulke A; van Vulpen, Marco; Philippens, Marielle E P

    2013-11-01

    Focal boosting of prostate tumours to improve outcome, requires accurate tumour delineation. For this, the apparent diffusion coefficient (ADC) derived from diffusion-weighted MR imaging (DWI) seems a useful tool. On voxel level, the relationship between ADC and histological presence of tumour is, however, ambiguous. Therefore, in this study the relationship between ADC and histological variables was investigated on voxel level to understand the strengths and limitations of DWI for prostate tumour delineation. Twelve radical prostatectomy patients underwent a pre-operative 3.0T DWI exam and the ADC was calculated. From whole-mount histological sections cell density and glandular area were retrieved for every voxel. The distribution of all variables was described for tumour, peripheral zone (PZ) and central gland (CG) on regional and voxel level. Correlations between variables and differences between regions were calculated. Large heterogeneity of ADC on voxel level was observed within tumours, between tumours and between patients. This heterogeneity was reflected by the distribution of cell density and glandular area. On regional level, tumour was different from PZ having higher cell density (p = 0.007), less glandular area (p = 0.017) and lower ADCs (p = 0.017). ADC was correlated with glandular area (r = 0.402) and tumour volume (r = -0.608), but not with Gleason score. ADC tended to decrease with increasing cell density (r = -0.327, p = 0.073). On voxel level, correlations between ADC and histological variables varied among patients, for cell density ranging from r = -0.439 to r = 0.261 and for glandular area from r = 0.593 to r = 0.207. The variation in ADC can to a certain extent be explained by the variation in cell density and glandular area. The ADC is highly heterogeneous, which reflects the heterogeneity of malignant and benign prostate tissue. This heterogeneity might however obscure small tumours or parts of tumours. Therefore, DWI has to be used in the context of multiparametric MRI.

  5. Quantification of breast density with spectral mammography based on a scanned multi-slit photon-counting detector: a feasibility study.

    PubMed

    Ding, Huanjun; Molloi, Sabee

    2012-08-07

    A simple and accurate measurement of breast density is crucial for the understanding of its impact in breast cancer risk models. The feasibility to quantify volumetric breast density with a photon-counting spectral mammography system has been investigated using both computer simulations and physical phantom studies. A computer simulation model involved polyenergetic spectra from a tungsten anode x-ray tube and a Si-based photon-counting detector has been evaluated for breast density quantification. The figure-of-merit (FOM), which was defined as the signal-to-noise ratio of the dual energy image with respect to the square root of mean glandular dose, was chosen to optimize the imaging protocols, in terms of tube voltage and splitting energy. A scanning multi-slit photon-counting spectral mammography system has been employed in the experimental study to quantitatively measure breast density using dual energy decomposition with glandular and adipose equivalent phantoms of uniform thickness. Four different phantom studies were designed to evaluate the accuracy of the technique, each of which addressed one specific variable in the phantom configurations, including thickness, density, area and shape. In addition to the standard calibration fitting function used for dual energy decomposition, a modified fitting function has been proposed, which brought the tube voltages used in the imaging tasks as the third variable in dual energy decomposition. For an average sized 4.5 cm thick breast, the FOM was maximized with a tube voltage of 46 kVp and a splitting energy of 24 keV. To be consistent with the tube voltage used in current clinical screening exam (∼32 kVp), the optimal splitting energy was proposed to be 22 keV, which offered a FOM greater than 90% of the optimal value. In the experimental investigation, the root-mean-square (RMS) error in breast density quantification for all four phantom studies was estimated to be approximately 1.54% using standard calibration function. The results from the modified fitting function, which integrated the tube voltage as a variable in the calibration, indicated a RMS error of approximately 1.35% for all four studies. The results of the current study suggest that photon-counting spectral mammography systems may potentially be implemented for an accurate quantification of volumetric breast density, with an RMS error of less than 2%, using the proposed dual energy imaging technique.

  6. [Glandular squamous cell carcinoma of the urinary bladder].

    PubMed

    Kovylina, M V; Pushkar', D Iu; Zaĭrat'iants, O V; Rasner, P I

    2006-01-01

    The paper gives a clinical observation of a 52 year-old male with a rare histological urinary bladder tumor primary grandular-squamous-cell carcinoma (pT3N IM0). The tumor is represented by two components large acinic-cell adenocarcinoma and squamous-cell carcinoma with keratinization, which smoothly pass one into another; the tumor has grown through all layers of the urinary bladder wall but it has failed to grow into the peritoneum. A microscopic study has indicated that the urachus is intact. Metastases were found in 3 of 8 lymph nodes: one showed high-grade adenocarcinoma and two others displayed average-grade squamous-cell carcinoma.

  7. Histopathological evaluation of gastro protective effect of Berberis vulgaris (Zereshk) seeds against aspirin induced ulcer in albino mice.

    PubMed

    Majeed, Wafa; Aslam, Bilal; Javed, Ijaz; Khaliq, Tanweer; Muhammad, Faqir; Ali, Asghar; Raza, Ahmed

    2015-11-01

    The present study was carried out to investigate the antiulcer activity of Berberis vulgaris (Zereshk) seeds in albino mice. After acclimatization, animals were divided into six equal groups. Aspirin 150 mg/kg was used to induce gastric ulcer in all groups except normal control. Omeprazole 20mg/kg was used as synthetic anti ulcer drug in study. Three dose levels of B. vulgaris seed powder 300 mg/kg, 600 mg/kg and 900 mg/kg were used respectively orally. Histopathological analysis was carried out to evaluate the gastroprotective activity of B. vulgaris seed powder. Results of the study showed that in case of aspirin treated mice gastric luminal mucosa villi were decreased in height or were absent. In the glandular region there was connective tissue proliferation and also infiltration of cells. Similar infiltration of cells was present on muscularis mucosa. In esophageal region tumor cells were present. However three dose levels of B. vulgaris significantly reduced the tissue proliferation, infiltration of cells and sloughing induced by aspirin. Highest dose of B. vulgaris (900 mg/kg) showed similar results as synthetic antiulcer drug omeprazole.

  8. GLANDULAR TRICHOME-SPECIFIC WRKY 1 promotes artemisinin biosynthesis in Artemisia annua.

    PubMed

    Chen, Minghui; Yan, Tingxiang; Shen, Qian; Lu, Xu; Pan, Qifang; Huang, Youran; Tang, Yueli; Fu, Xueqing; Liu, Meng; Jiang, Weimin; Lv, Zongyou; Shi, Pu; Ma, Ya-Nan; Hao, Xiaolong; Zhang, Lida; Li, Ling; Tang, Kexuan

    2017-04-01

    Artemisinin is a type of sesquiterpene lactone well known as an antimalarial drug, and is specifically produced in glandular trichomes of Artemisia annua. However, the regulatory network for the artemisinin biosynthetic pathway remains poorly understood. Exploration of trichome-specific transcription factors would facilitate the elucidation of regulatory mechanism of artemisinin biosynthesis. The WRKY transcription factor GLANDULAR TRICHOME-SPECIFIC WRKY 1 (AaGSW1) was cloned and analysed in A. annua. AaGSW1 exhibited similar expression patterns to the trichome-specific genes of the artemisinin biosynthetic pathway and AP2/ERF transcription factor AaORA. A β-glucuronidase (GUS) staining assay further demonstrated that AaGSW1 is a glandular trichome-specific transcription factor. AaGSW1 positively regulates CYP71AV1 and AaORA expression by directly binding to the W-box motifs in their promoters. Overexpression of AaGSW1 in A. annua significantly improves artemisinin and dihydroartemisinic acid contents; moreover, AaGSW1 can be directly regulated by AaMYC2 and AabZIP1, which are positive regulators of jasmonate (JA)- and abscisic acid (ABA)-mediated artemisinin biosynthetic pathways, respectively. These results demonstrate that AaGSW1 is a glandular trichome-specific WRKY transcription factor and a positive regulator in the artemisinin biosynthetic pathway. Moreover, we propose that two trifurcate feed-forward pathways involving AaGSW1, CYP71AV1 and AaMYC2/AabZIP1 function in the JA/ABA response in A. annua. © 2016 The Authors. New Phytologist © 2016 New Phytologist Trust.

  9. Fibroblast Growth Factor 10-Fibroblast Growth Factor Receptor 2b Mediated Signaling Is Not Required for Adult Glandular Stomach Homeostasis

    PubMed Central

    Sala, Frederic G.; Ford, Henri R.; Bellusci, Saverio; Grikscheit, Tracy C.

    2012-01-01

    The signaling pathways that are essential for gastric organogenesis have been studied in some detail; however, those that regulate the maintenance of the gastric epithelium during adult homeostasis remain unclear. In this study, we investigated the role of Fibroblast growth factor 10 (FGF10) and its main receptor, Fibroblast growth factor receptor 2b (FGFR2b), in adult glandular stomach homeostasis. We first showed that mouse adult glandular stomach expressed Fgf10, its receptors, Fgfr1b and Fgfr2b, and most of the other FGFR2b ligands (Fgf1, Fgf7, Fgf22) except for Fgf3 and Fgf20. Fgf10 expression was mesenchymal whereas FGFR1 and FGFR2 expression were mostly epithelial. Studying double transgenic mice that allow inducible overexpression of Fgf10 in adult mice, we showed that Fgf10 overexpression in normal adult glandular stomach increased epithelial proliferation, drove mucous neck cell differentiation, and reduced parietal and chief cell differentiation. Although a similar phenotype can be associated with the development of metaplasia, we found that Fgf10 overexpression for a short duration does not cause metaplasia. Finally, investigating double transgenic mice that allow the expression of a soluble form of Fgfr2b, FGF10's main receptor, which acts as a dominant negative, we found no significant changes in gastric epithelial proliferation or differentiation in the mutants. Our work provides evidence, for the first time, that the FGF10-FGFR2b signaling pathway is not required for epithelial proliferation and differentiation during adult glandular stomach homeostasis. PMID:23133671

  10. Differential microRNA Analysis of Glandular Trichomes and Young Leaves in Xanthium strumarium L. Reveals Their Putative Roles in Regulating Terpenoid Biosynthesis

    PubMed Central

    Fan, Rongyan; Li, Yuanjun; Li, Changfu; Zhang, Yansheng

    2015-01-01

    The medicinal plant Xanthium strumarium L. (X. strumarium) is covered with glandular trichomes, which are the sites for synthesizing pharmacologically active terpenoids such as xanthatin. MicroRNAs (miRNAs) are a class of 21–24 nucleotide (nt) non-coding RNAs, most of which are identified as regulators of plant growth development. Identification of miRNAs involved in the biosynthesis of plant secondary metabolites remains limited. In this study, high-throughput Illumina sequencing, combined with target gene prediction, was performed to discover novel and conserved miRNAs with potential roles in regulating terpenoid biosynthesis in X. strumarium glandular trichomes. Two small RNA libraries from leaves and glandular trichomes of X. strumarium were established. In total, 1,185 conserved miRNAs and 37 novel miRNAs were identified, with 494 conserved miRNAs and 18 novel miRNAs being differentially expressed between the two tissue sources. Based on the X. strumarium transcriptome data that we recently constructed, 3,307 annotated mRNA transcripts were identified as putative targets of the differentially expressed miRNAs. KEGG (Kyoto Encyclopedia of Genes and Genomes) pathway analysis suggested that some of the differentially expressed miRNAs, including miR6435, miR5021 and miR1134, might be involved in terpenoid biosynthesis in the X. strumarium glandular trichomes. This study provides the first comprehensive analysis of miRNAs in X. strumarium, which forms the basis for further understanding of miRNA-based regulation on terpenoid biosynthesis. PMID:26406988

  11. Trichoderma species form endophytic associations within Theobroma cacao trichomes.

    PubMed

    Bailey, Bryan A; Strem, Mary D; Wood, Delilah

    2009-12-01

    Trichoderma species are usually considered soil organisms that colonize plant roots, sometimes forming a symbiotic relationship. Recent studies demonstrate that Trichoderma species are also capable of colonizing the above ground tissues of Theobroma cacao (cacao) in what has been characterized as an endophytic relationship. Trichoderma species can be re-isolated from surface sterilized cacao stem tissue, including the bark and xylem, the apical meristem, and to a lesser degree from leaves. SEM analysis of cacao stems colonized by strains of four Trichoderma species (Trichoderma ovalisporum-DIS 70a, Trichoderma hamatum-DIS 219b, Trichoderma koningiopsis-DIS 172ai, or Trichoderma harzianum-DIS 219f) showed a preference for surface colonization of glandular trichomes versus non-glandular trichomes. The Trichoderma strains colonized the glandular trichome tips and formed swellings resembling appresoria. Hyphae were observed emerging from the glandular trichomes on surface sterilized stems from cacao seedlings that had been inoculated with each of the four Trichoderma strains. Fungal hyphae were observed under the microscope emerging from the trichomes as soon as 6h after their isolation from surface sterilized cacao seedling stems. Hyphae were also observed, in some cases, emerging from stalk cells opposite the trichome head. Repeated single trichome/hyphae isolations verified that the emerging hyphae were the Trichoderma strains with which the cacao seedlings had been inoculated. Strains of four Trichoderma species were able to enter glandular trichomes during the colonization of cacao stems where they survived surface sterilization and could be re-isolated. The penetration of cacao trichomes may provide the entry point for Trichoderma species into the cacao stem allowing systemic colonization of this tissue.

  12. Structural changes in endometrial basal glands during menstruation.

    PubMed

    Garry, R; Hart, R; Karthigasu, K A; Burke, C

    2010-09-01

    To prospectively observe the changes occurring in endometrial glandular morphology during menstrual shedding and regeneration. Prospective observational study. The academic gynaecological endoscopy unit of a university teaching hospital. Population Thirteen patients investigated for a variety of benign, non-infective gynaecological disorders during the active bleeding phase of the menstrual cycle. The morphological appearances of concurrent histological and scanning electron microscopic images of endometrium taken at different stages of the active bleeding phase of menstruation were studied and correlated with the simultaneous immunohistochemical expression of the Ki-67 proliferation marker and the CD68 marker of macrophage activity. Change in morphology of endometrial glands at various stages of menstruation. Endometrial glands within the basalis show evidence of apoptosis and associated macrophage activity immediately before and during menstruation. There is subsequent destruction and removal of old secretory glandular epithelial elements, and rapid replacement with new narrow glands lined with small epithelial cells. There is no evidence of mitotic cell division or expression of Ki-67 in the glandular cells during this replacement process, but there is evidence of marked macrophage activity prior to glandular cell loss. Early endometrial epithelial repair after menstruation is not a consequence of mitotic cell division. It occurs without evidence of Ki-67 expression. There is structural evidence of programmed cell death and intense macrophage activity associated with glandular remodelling. Dead epithelial cells are shed from the glands and accumulate within the endometrial cavity to be replaced by new small epithelial cells that appear to arise by differentiation of the surrounding stromal cells. We propose that these stromal cells are endometrial progenitor/stem cells.

  13. Diagnosis of ocular and glandular toxoplasmosis using the Indian ink immunoreaction.

    PubMed

    Safar, E H; Azab, M E; Osman, Z M

    1984-01-01

    The Indian ink immunoreaction (IIR) as a method for diagnosis of Toxoplasma infection has been evaluated. 68 sera from patients with suspected ocular and glandular toxoplasmosis and 30 control sera from normal individuals were tested using both indirect fluorescent antibody test (IFAT) and IIR. The test proved to be specific, simple and rapid especially for screening purposes.

  14. Oil-producing flowers within the Iridoideae (Iridaceae): evolutionary trends in the flowers of the New World genera.

    PubMed

    Chauveau, Olivier; Eggers, Lilian; Souza-Chies, Tatiana T; Nadot, Sophie

    2012-08-01

    Oil-producing flowers related to oil-bee pollination are a major innovation in Neotropical and Mexican Iridaceae. In this study, phylogenetic relationships were investigated among a wide array of New World genera of the tribes Sisyrinchieae, Trimezieae and Tigridieae (Iridaceae: Iridoideae) and the evolution of floral glandular structures, which are predominantly trichomal elaiophores, was examined in relation to the diversification of New World Iridaceae. Phylogenetic analyses based on seven molecular markers obtained from 97 species were conducted to produce the first extensive phylogeny of the New World tribes of subfamily Iridoideae. The resulting phylogenetic hypothesis was used to trace the evolutionary history of glandular structures present in the flowers of numerous species in each tribe. Hypotheses of differential diversification rates among lineages were also investigated using both topological and Binary-State Speciation and Extinction methods. Floral glandular structures and especially trichomal elaiophores evolved multiple times independently in the American tribes of Iridoideae. The distribution pattern of species displaying glandular trichomes across the phylogeny reveals lability in the pollination system and suggests that these structures may have played a significant role in the diversification of the Iridoideae on the American continent.

  15. Antibacterial, modulatory activity of antibiotics and toxicity from Rhinella jimi (Stevaux, 2002) (Anura: Bufonidae) glandular secretions.

    PubMed

    Sales, Débora Lima; Morais-Braga, Maria Flaviana Bezerra; Santos, Antonia Thassya Lucas Dos; Machado, Antonio Judson Targino; Araujo Filho, João Antonio de; Dias, Diógenes de Queiroz; Cunha, Francisco Assis Bezerra da; Saraiva, Rogério de Aquino; Menezes, Irwin Rose Alencar de; Coutinho, Henrique Douglas Melo; Costa, José Galberto Martins; Ferreira, Felipe Silva; Alves, Rômulo Romeu da Nóbrega; Almeida, Waltécio de Oliveira

    2017-08-01

    The increase in microorganisms with resistance to medications has caused a strong preoccupation within the medical and scientific community. Animal toxins studies, such as parotoid glandular secretions from amphibians, possesses a great potential in the development of drugs, such as antimicrobials, as these possess bioactive compounds. It was evaluated Rhinella jimi (Stevaux, 2002) glandular secretions against standard and multi-resistant bacterial strains; the effect of secretions combined with drugs; and determined the toxicity using two biologic in vivo models, and a in vitro model with mice livers. Standard strains were used for the determination of the Minimum Inhibitory Concentration (MIC), while for the modulatory activity of antibiotics, the clinical isolates Escherichia coli 06, Pseudomonas aeruginosa 03 and Staphylococcus aureus 10 were used. Modulatory activity was evaluated by the broth microdilution method with aminoglycosides and β-lactams as target antibiotics. The secretions in association with the antibiotics have a significant reduction in MIC, both the aminoglycosides and β-lactams. The toxicity and cytotoxicity results were lower than the values used in the modulation. R. jimi glandular secretions demonstrated clinically relevant results regarding the modulation of the tested antimicrobials. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. Atypical squamous and glandular cells of undetermined significance (ASCUS and AGUS) of the uterine cervix.

    PubMed

    Cenci, M; Vecchione, A

    2000-01-01

    ASCUS (Atypical Squamous Cells of Undetermined Significance) and AGUS (Atypical Glandular Cells of Undetermined Significance), or AGCUS, are two acronyms introduced in 1988 by The Bethesda System (TBS) for reporting borderline cytological changes in cervical cytology. ASCUS and AGUS categories should be subclassified. Five ASCUS subgroups were proposed: 1) ASCUS due to processing defects, 2) with "mature" cytoplasm, 3) in post-menopausal women (a--in the setting of atrophy and b--with estrogen stimulation), 4) atypical metaplasia, and 5) ASCUS with keratinized cytoplasm. AGUS subgroups may be subcategorized in endometrial or endocervical on the basis of origin. Endocervical AGUS should be further qualified, but the analysis of atypical glandular cells may be really difficult and the conclusive diagnosis is frequently "AGUS not otherwise specified". The subclassification of ASCUS and AGUS is useful for an appropriate clinical management, but pertinent patient information (such as age, date of last menstrual period, mechanical therapies, tamoxifen therapy, and others) is needed to avoid an overdiagnosis and consequently an overtreatment. In fact various subgroups require different clinical management. Therefore, an effective communication between cytopathologists and referring physicians is essential in the analysis of squamous and glandular atypias.

  17. Tripartite differentiation (squamous, glandular, and melanocytic) of a primary cutaneous neuroendocrine carcinoma. An immunocytochemical and ultrastructural study.

    PubMed

    Isimbaldi, G; Sironi, M; Taccagni, G; Declich, P; Dell'Antonio, A; Galli, C

    1993-06-01

    We report a case of primary cutaneous neuroendocrine carcinoma (PCNEC) with squamous, glandular, and melanocytic differentiation and associated Bowen disease. The paranuclear globular positivity of low-molecular-weight cytokeratins agrees with the ultrastructural observations of paranuclear fibrous bodies in the small neuroendocrine cells, while the diffuse cytoplasmic positivity corresponds to the sparse intermediate filaments in large cells with squamous differentiation. "Transitional forms" are characterized by both diffuse and globular cytoplasmic positivity for cytokeratins and by the ultrastructural evidence of neuroendocrine and squamous features. Therefore the ultrastructural demonstration of intracytoplasmic tonofibrils and tonofilaments, intercellular glandular lumina, lined by well-formed microvilli, and immature premelanosomes in the neurosecretory cells supports the proposed tripartite differentiation of neuroendocrine cells of this case of PCNEC.

  18. GEOPHYSICS, ASTRONOMY AND ASTROPHYSICS: Second-harmonic generation as a DNA malignancy indicator of prostate glandular epithelial cells

    NASA Astrophysics Data System (ADS)

    Zhuang, Zheng-Fei; Liu, Han-Ping; Guo, Zhou-Yi; Zhuo, Shuang-Mu; Yu, Bi-Ying; Deng, Xiao-Yuan

    2010-04-01

    This paper first demonstrates second-harmonic generation (SHG) in the intact cell nucleus, which acts as an optical indicator of DNA malignancy in prostate glandular epithelial cells. Within a scanning region of 2.7 μm×2.7 μm in cell nuclei, SHG signals produced from benign prostatic hyperplasia (BPH) and prostate carcinoma (PC) tissues (mouse model C57BL/6) have been investigated. Statistical analyses (t test) of a total of 405 measurements (204 nuclei from BPH and 201 nuclei from PC) show that SHG signals from BPH and PC have a distinct difference (p < 0.05), suggesting a potential optical method of revealing very early malignancy in prostate glandular epithelial cells based upon induced biochemical and/or biophysical modifications in DNA.

  19. SU-C-207-02: A Method to Estimate the Average Planar Dose From a C-Arm CBCT Acquisition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Supanich, MP

    2015-06-15

    Purpose: The planar average dose in a C-arm Cone Beam CT (CBCT) acquisition had been estimated in the past by averaging the four peripheral dose measurements in a CTDI phantom and then using the standard 2/3rds peripheral and 1/3 central CTDIw method (hereafter referred to as Dw). The accuracy of this assumption has not been investigated and the purpose of this work is to test the presumed relationship. Methods: Dose measurements were made in the central plane of two consecutively placed 16cm CTDI phantoms using a 0.6cc ionization chamber at each of the 4 peripheral dose bores and in themore » central dose bore for a C-arm CBCT protocol. The same setup was scanned with a circular cut-out of radiosensitive gafchromic film positioned between the two phantoms to capture the planar dose distribution. Calibration curves for color pixel value after scanning were generated from film strips irradiated at different known dose levels. The planar average dose for red and green pixel values was calculated by summing the dose values in the irradiated circular film cut out. Dw was calculated using the ionization chamber measurements and film dose values at the location of each of the dose bores. Results: The planar average dose using both the red and green pixel color calibration curves were within 10% agreement of the planar average dose estimated using the Dw method of film dose values at the bore locations. Additionally, an average of the planar average doses calculated using the red and green calibration curves differed from the ionization chamber Dw estimate by only 5%. Conclusion: The method of calculating the planar average dose at the central plane of a C-arm CBCT non-360 rotation by calculating Dw from peripheral and central dose bore measurements is a reasonable approach to estimating the planar average dose. Research Grant, Siemens AG.« less

  20. The Installation Restoration Program Toxicology Guide. Volume 1

    DTIC Science & Technology

    1989-07-01

    affinity for adipose tissue , which is more prevalent in women and would result in less unchanged chloroform and more carbon dioxide exhaled. This...magnesium, potassium, sodium, tin, zinc , and their alloys. ADI Acceptable daily intake ADL Arthur D. Little, Inc. Adenocarcinoma A malignant tumor...originating in glandular or ductal epithelium. Adenoma A benign growth of glandular tissue . ae Acid equivalent Aerosol A suspension or dispersion of small

  1. Endometrial Polyps and Benign Endometrial Hyperplasia Present Increased Prevalence of DNA Fragmentation Factors 40 and 45 (DFF40 and DFF45) Together With the Antiapoptotic B-Cell Lymphoma (Bcl-2) Protein Compared With Normal Human Endometria.

    PubMed

    Banas, Tomasz; Pitynski, Kazimierz; Mikos, Marcin; Cielecka-Kuszyk, Joanna

    2017-09-13

    DNA fragmentation factor 40 (DFF40) is a key executor of apoptosis. It localizes to the nucleus together with DNA fragmentation factor 45 (DFF45), which acts as a DFF40 inhibitor and chaperone. B-cell lymphoma (Bcl-2) protein is a proven antiapoptotic factor present in the cytoplasm. In this study, we aimed to investigate DFF40, DFF45, and Bcl-2 immunoexpression in endometrial polyps (EPs) and benign endometrial hyperplasia (BEH) tissue compared with that in normal proliferative endometrium (NPE) and normal secretory endometrium (NSE) as well as normal post menopausal endometrium (NAE). This study used archived samples from 65 and 62 cases of EPs and BEH, respectively. The control group consisted of 52 NPE, 54 NSE, and 54 NAE specimens. Immunohistochemistry was used to detect DFF40, DFF45, and Bcl-2. DFF40, DFF45, and Bcl-2 were more highly expressed in the glandular layer of EPs and BEH compared with the stroma, and this was not influenced by menopausal status. Both glandular and stromal expression of DFF40, DFF45, and Bcl-2 were significantly higher in EPs compared with NPE, NSE, and NAE. Glandular BEH tissue showed significantly higher DFF40, DFF45, and Bcl-2 expression than in NPE, NSE, and NAE. No differences in the glandular expression of DFF40, DFF45, and Bcl-2 were observed between EP and BEH tissues, while Bcl-2 stromal expression in BEH was significantly lower than in EPs. Glandular, menopause-independent DFF40, DFF45, and Bcl-2 overexpression may play an important role in the pathogenesis of EPs and BEH.

  2. Hypanocotyle bullardi n. gen. n. sp. (Monogenea: Hexabothriidae) from gill of the diamond stingray Hypanus dipterurus (Jordan et Gilbert) (Myliobatiformes: Dasyatidae) in the Southeastern Pacific Ocean off Peru.

    PubMed

    Chero, Jhon D; Cruces, Celso L; Sáez, Gloria; Camargo, Ana Carolina A; Santos, Cláudia Portes; Luque, José L

    2018-08-01

    A new genus and species of monogenean belonging to Hexabothriidae, Hypanocotyle bullardi n. gen. n. sp., is described based on specimens collected from the gill filaments of the diamond stingray, Hypanus dipterurus (Jordan et Gilbert) (Myliobatiformes: Dasyatidae), a demersal chondrichthyan collected off the coast of Callao, Peru. Hypanocotyle n. gen. has the following combination of diagnostic features that differentiate it from other hexabothriid genera: haptor symmetrical; vasa efferentia having proximal (narrow, with thin glandular wall) and distal (expanded, interlaced, with thick glandular wall) portions, joining medially to form vas deferens; vas deferens having proximal (expanded, sinuous, with thick glandular wall) and distal (narrow, strongly sinuous, with thin glandular wall) portions; male copulatory organ unarmed, proximal portion slightly sinuous and tube-like, distal portion funnel-shaped; prostatic glands present, distributed around of the MCO; seminal receptacle present; ootype lacking longitudinal rows of large cells (no oötype côtelé); vaginae parallel, with well-differentiated proximal (glandular, narrow, tube-like, slightly sinuous) and distal (musculoglandular, convoluted) portions; gland cells surrounding the vaginal duct along the entire length of distal portion, densely clustered in middle portion; uterine eggs with 2 elongate filaments. Phylogenetic reconstructions by maximum-likelihood method, based on newly obtained partial 18S and 28S sequences, shows that H. bullardi n. gen. is included within the family Hexabothriidae, order Diclybothriidea. This is the second hexabothriid genus recorded from a diamond stingray (Dasyatidae), and the fourth hexabothriid species recorded from Peru. A key to hexabothriid genera is provided. Copyright © 2018. Published by Elsevier B.V.

  3. Exocrine and endocrine release of kallikrein after reflex-induced salivary secretion.

    PubMed

    Berg, T; Johansen, L; Poulsen, K

    1990-05-01

    Exocrine and endocrine release of rat submandibular gland kallikrein has been shown to be low after parasympathetic and beta-adrenergic stimulation but greatly increased after alpha-adrenergic stimulation. In the present study, release of glandular kallikrein was investigated under conditions known to give a reflex-induced salivary gland response. Heat stress induced a rich flow of saliva originating in the submandibular glands. Salivary kallikrein secretory rate was higher than after parasympathetic stimulation but lower than after sympathetic stimulation (P less than 0.005). Only heat stress increased circulating glandular kallikrein (12.7 +/- 0.8 ng ml-1 before heat exposure and 53.3 +/- 14.1 ng ml-1 40 min afterwards, P less than 0.005). There were no indications that the endocrine release of kallikrein was due to non-specific leakage. Atropine abolished heat-induced salivation and endocrine kallikrein secretion, possibly through interference with central pathways (P less than 0.05). However, phentolamine did not, which may indicate as an yet unidentified mediator of endogenous kallikrein release. The salivary gland response to acid and ether was comparable to that observed after parasympathetic nerve stimulation and was abolished by atropine (P less than 0.005). Stimuli known to influence other salivary gland ductal cells, such as aggression and starvation followed by drinking, also did not increase the plasma concentration of glandular kallikrein. The fact that various conditions which induce salivation did not increase circulating glandular kallikrein, coupled with the fact that kallikrein concentration was the highest in animals that died from heat stress, may suggest that the increase in circulating glandular kallikrein seen after heat stress may be pathological and could contribute to the development of heat shock.

  4. Long-Term Follow-up of Recurrence and Patient Satisfaction After Surgical Treatment of Gynecomastia.

    PubMed

    Fricke, A; Lehner, G M; Stark, G B; Penna, V

    2017-06-01

    "Gynecomastia" is an enlargement of the male breast. Our study aims to assess patient satisfaction as well as evaluate differences in recurrence rates in lipomatous and glandular gynecomastia 10-19 years postoperatively. Forty-one gynecomastia patients undergoing surgical treatment from 1997 to 2005 were invited for a follow-up examination 10-19 years postoperatively. Of these, 16 patients presented for a clinical examination. Patient satisfaction was measured with a validated questionnaire [consultation satisfaction questionnaire (CSQ)-9]. Furthermore, photo-material and patient charts were evaluated concerning preoperative macroscopical type of gynecomastia, BMI, and operative technique. Mean follow-up time was 13.8 years (range: 10.5-19 years). Eight patients (50%) had presented with lipomatous and eight patients (50%) with glandular gynecomastia prior to surgery. One of the patients with glandular gynecomastia (12.5%) presented with recurrence at the time of follow-up, while five of the eight patients showing lipomatous gynecomastia (62.5%) presented with recurrence. Interestingly, younger patient groups tend to be more satisfied with the operative treatment of gynecomastia than older patient groups, especially regarding the improvement of self-esteem. Long-term follow-up results showed that recurrence rates are significantly higher in patients with lipomatous gynecomastia than in patients with glandular gynecomastia, with BMI increase in patients with glandular and lipomatous gynecomastia showing no statistically significant differences. Furthermore, general patient satisfaction and improvement of self-esteem was higher in younger patient groups than older patient groups. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 . DRKS00009630.

  5. A retrospective study: correlation of histologic inflammation in biopsy specimens of Chinese men undergoing surgery for benign prostatic hyperplasia with serum prostate-specific antigen.

    PubMed

    Song, Lingmin; Zhu, Yuchun; Han, Ping; Chen, Ni; Lin, Dao; Lai, Jianyu; Wei, Qiang

    2011-03-01

    To reveal the correlation between benign prostatic hyperplasia (BPH) histologic inflammation and serum prostate-specific antigen (sPSA) concentrations, and the possible mechanism. Patients underwent surgery at the Urology Department of West China Hospital of Sichuan University were retrospectively studied. Preoperative sPSA and transrectal ultrasonography were measured. According to the histopathological classification system for chronic prostatic inflammation proposed by the Chronic Prostatitis Collaborative Research Network (CPCRN) and the International Prostatitis Collaborative Network (IPCN), we classified the histologic sections of prostatic biopsy into glandular, periglandular, and stromal inflammation by the anatomical location of inflammatory infiltration. The glandular inflammation was graded according to the inflammatory aggressiveness. The periglandular and stromal inflammation were graded according to the inflammatory density. The correlation between histologic inflammation and sPSA was studied by a multiple regression model in conjunction with age and total prostatic volume. A total of 454 patients with exclusively BPH were analyzed. The periglandular inflammatory infiltration was the most common pattern (95.6%). Single regression analysis revealed that total prostatic volume, the aggressiveness of glandular inflammation, and the intensity of periglandular and stromal inflammation were correlated with sPSA. However, the multiple regression analysis revealed that only the total prostatic volume and the aggressiveness of glandular inflammation were correlated significantly with sPSA (R = .389, 0.289; P = .000). The aggressiveness of glandular inflammatory infiltration in BPH is a significant contributor to elevated sPSA levels. The theory of leakage may be the most reasonable mechanism to reveal the correlation morphologically. We should take inflammation into consideration when interpreting the abnormal elevating of sPSA levels. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Coadministration of puerarin (low dose) and zinc attenuates bone loss and suppresses bone marrow adiposity in ovariectomized rats.

    PubMed

    Liu, Hao; Li, Wei; Ge, Xiyuan; Jia, Shengnan; Li, Binbin

    2016-12-01

    Puerarin is a phytoestrogen that shows osteogenic effects. Meanwhile, zinc stimulates bone formation and inhibits bone resorption. The study aims to investigate the effects of coadministration of puerarin (low dose) and zinc on bone formation in ovariectomized rats. Co-administration or use alone of puerarin (low dose) and/or zinc were gavaged in OVX rats. The estrogen-like effects were detected by the uterus weight, the histologic observation and the IGF-1 protein expression. The osteogenic effects were determined by bone histomorphometric and mechanical parameters, osteogenic and adipogenic blood markers, and so on. The results showed that oral administration of puerarin (low dose) plus zinc didn't significantly increase uterus weight. The glandular epithelial of endometrium had no proliferation and no protein expression of IGF-1. Moreover, co-administration attenuated bone loss and biomechanical decrease more than single use of puerarin or zinc (p<0.05). Next, combined administration of puerarin and zinc promoted the serological level of osteocalcin, bone marrow stromal cell (BMSC) proliferation, and the expression of alkaline phosphatase (ALP), and suppressed the serological level of adiponectin and adiposity in bone marrow (BM). In conclusion, co-administrated puerarin (low dose) and zinc can partially reverse OVX-induced bone loss and suppress the adiposity of BM in rats, which shed light on the potential use of puerarin and zinc in the treatment of osteoporosis. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Breast tissue decomposition with spectral distortion correction: A postmortem study

    PubMed Central

    Ding, Huanjun; Zhao, Bo; Baturin, Pavlo; Behroozi, Farnaz; Molloi, Sabee

    2014-01-01

    Purpose: To investigate the feasibility of an accurate measurement of water, lipid, and protein composition of breast tissue using a photon-counting spectral computed tomography (CT) with spectral distortion corrections. Methods: Thirty-eight postmortem breasts were imaged with a cadmium-zinc-telluride-based photon-counting spectral CT system at 100 kV. The energy-resolving capability of the photon-counting detector was used to separate photons into low and high energy bins with a splitting energy of 42 keV. The estimated mean glandular dose for each breast ranged from 1.8 to 2.2 mGy. Two spectral distortion correction techniques were implemented, respectively, on the raw images to correct the nonlinear detector response due to pulse pileup and charge-sharing artifacts. Dual energy decomposition was then used to characterize each breast in terms of water, lipid, and protein content. In the meantime, the breasts were chemically decomposed into their respective water, lipid, and protein components to provide a gold standard for comparison with dual energy decomposition results. Results: The accuracy of the tissue compositional measurement with spectral CT was determined by comparing to the reference standard from chemical analysis. The averaged root-mean-square error in percentage composition was reduced from 15.5% to 2.8% after spectral distortion corrections. Conclusions: The results indicate that spectral CT can be used to quantify the water, lipid, and protein content in breast tissue. The accuracy of the compositional analysis depends on the applied spectral distortion correction technique. PMID:25281953

  8. Effect of high-dose vocal fold injection of cidofovir and bevacizumab in a porcine model.

    PubMed

    Ahmed, Mostafa M; Connor, Matthew P; Palazzolo, Mitzi; Thompson, Michelle E; Lospinoso, Josh; O'Connor, Peter; Howard, N Scott; Maturo, Stephen C

    2017-03-01

    Perform a follow-up study to investigate the histologic impact of high-dose intralaryngeal cidofovir injections in porcine vocal cords, either alone or in combination with bevacizumab, and compared to saline controls. This was an in vivo study involving 24 pigs with blinded pathologist review of specimens. Six groups were created, with four subjects in each group. Each subject received 10 or 20 mg of either cidofovir or bevacizumab alone, or in combination, injected into the right vocal cord. The left vocal fold was used as a saline control. Three separate injections were made at 2-week intervals. Larynges were harvested at 8 and 12 weeks, stained with hematoxylin and eosin and trichrome stain, and reviewed for histologic changes by two blinded pathologists. Minimal inflammation, edema, and atypia were noted with all treatments. Increased glandular inflammation was noted with 10 mg bevacizumab (P < 0.05), which decreased when combined with 10 mg cidofovir (P < 0.05). No lamina propria or muscle fibrosis was observed. Drug duration had no statistically significant histologic impact. High-dose cidofovir and bevacizumab do not induce detrimental vocal fold changes. Combination cidofovir and bevacizumab do not cause vocal fold scarring. Further work is needed to assess systemic concentration with this high-dose combination in humans. N/A. Laryngoscope, 127:671-675, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baconnais, S.; Delavoie, F.; Zahm, J.M.

    The absence or decreased expression of cystic fibrosis transmembrane conductance regulator (CFTR) induces increased Na{sup +} absorption and hyperabsorption of the airway surface liquid (ASL) resulting in a dehydrated and hyperviscous ASL. Although the implication of abnormal airway submucosal gland function has been suggested, the ion and water content in the Cystic Fibrosis (CF) glandular secretory granules, before exocytosis, is unknown. We analyzed, in non-CF and CF human airway glandular cell lines (MM-39 and KM4, respectively), the ion content in the secretory granules by electron probe X-ray microanalysis and the water content by quantitative dark field imaging on freeze-dried cryosections.more » We demonstrated that the ion content (Na{sup +}, Mg{sup 2+}, P, S and Cl{sup -}) is significantly higher and the water content significantly lower in secretory granules from the CF cell line compared to the non-CF cell line. Using videomicroscopy, we observed that the secretory granule expansion was deficient in CF glandular cells. Transfection of CF cells with CFTR cDNA or inhibition of non-CF cells with CFTR{sub inh}-172, respectively restored or decreased the water content and granule expansion, in parallel with changes in ion content. We hypothesize that the decreased water and increased ion content in glandular secretory granules may contribute to the dehydration and increased viscosity of the ASL in CF.« less

  10. Rat gastric mucins recognized by monoclonal antibodies RGM21 and HIK1083: isolation of mucin species characteristic of the surface and glandular mucosa.

    PubMed

    Goso, Y; Ishihara, K; Kurihara, M; Sugaya, T; Hotta, K

    1999-08-01

    Whole mucins and reduced subunits were extracted from the corpus of the rat stomach. After purification by Sepharose CL-4B chromatography followed by cesium trifluoroacetate equilibrium centrifugation, they were analyzed by Sepharose CL-2B chromatography, rate-zonal sedimentation centrifugation, and Q-Sepharose chromatography. Monoclonal antibodies RGM21 and HIK1083, which histochemically stained mucins in the surface and glandular mucosa of the rat stomach, respectively, were used to detect the site-specific mucins. Although RGM21- and HIK1083-reactive mucins both had a multimerized structure, the density and size of both the whole mucins and reduced subunits differed, thus indicating the presence of distinct mucin species in the surface and glandular mucosa. The mucin subunits were separated into four fractions, UB, B1, B2a, and B2b, by Q-Sepharose chromatography. HIK1083 reacted mainly with UB, while RGM21 reacted with B1, B2a, and B2b. These results, combined with dot-blot, amino acid, and carbohydrate composition analyses, showed that the surface mucins may consist of three kinds of subunits. In contrast, the glandular mucins may consist of one kind of subunit which differs from that of surface mucins.

  11. Solitary glandular papilloma of the peripheral lung: a report of two cases

    PubMed Central

    2014-01-01

    Solitary papilloma of the lung is thought to be a rare benign epithelial tumor, and complete surgical resection is currently the standard treatment for this pathology. However, some cases of papilloma have reportedly shown malignant potential. We report two cases of solitary glandular papilloma of the peripheral lung that were treated by thoracoscopic partial resection. The first patient presented with a nodular lesion in the lower lobe of the left lung that was detected on a follow-up chest computed tomography (CT) scan after treatment for laryngeal cancer. Partial lung resection was performed by video-assisted thoracoscopic surgery. In the second patient, a nodular lesion was incidentally identified in the lower lobe of the left lung during a health check-up. Partial lung resection was again performed by video-assisted thoracoscopic surgery. The postoperative course in both cases was uneventful, and no recurrences have been observed as of 44 months and 41 months postoperatively, respectively. To the best of our knowledge, malignant transformation has been reported both with the squamous type and the mixed type of solitary papilloma of the lung. The glandular variant has shown no tendency toward local recurrence after local excision and has no apparent malignant potential. Local excision is thus recommended for solitary glandular papilloma in order to preserve pulmonary function. PMID:24885310

  12. Solitary glandular papilloma of the peripheral lung: a report of two cases.

    PubMed

    Kaseda, Kaoru; Horio, Hirotoshi; Harada, Masahiko; Hishima, Tsunekazu

    2014-05-19

    Solitary papilloma of the lung is thought to be a rare benign epithelial tumor, and complete surgical resection is currently the standard treatment for this pathology. However, some cases of papilloma have reportedly shown malignant potential. We report two cases of solitary glandular papilloma of the peripheral lung that were treated by thoracoscopic partial resection. The first patient presented with a nodular lesion in the lower lobe of the left lung that was detected on a follow-up chest computed tomography (CT) scan after treatment for laryngeal cancer. Partial lung resection was performed by video-assisted thoracoscopic surgery. In the second patient, a nodular lesion was incidentally identified in the lower lobe of the left lung during a health check-up. Partial lung resection was again performed by video-assisted thoracoscopic surgery. The postoperative course in both cases was uneventful, and no recurrences have been observed as of 44 months and 41 months postoperatively, respectively. To the best of our knowledge, malignant transformation has been reported both with the squamous type and the mixed type of solitary papilloma of the lung. The glandular variant has shown no tendency toward local recurrence after local excision and has no apparent malignant potential. Local excision is thus recommended for solitary glandular papilloma in order to preserve pulmonary function.

  13. Oil-producing flowers within the Iridoideae (Iridaceae): evolutionary trends in the flowers of the New World genera

    PubMed Central

    Chauveau, Olivier; Eggers, Lilian; Souza-Chies, Tatiana T.; Nadot, Sophie

    2012-01-01

    Background and Aims Oil-producing flowers related to oil-bee pollination are a major innovation in Neotropical and Mexican Iridaceae. In this study, phylogenetic relationships were investigated among a wide array of New World genera of the tribes Sisyrinchieae, Trimezieae and Tigridieae (Iridaceae: Iridoideae) and the evolution of floral glandular structures, which are predominantly trichomal elaiophores, was examined in relation to the diversification of New World Iridaceae. Methods Phylogenetic analyses based on seven molecular markers obtained from 97 species were conducted to produce the first extensive phylogeny of the New World tribes of subfamily Iridoideae. The resulting phylogenetic hypothesis was used to trace the evolutionary history of glandular structures present in the flowers of numerous species in each tribe. Hypotheses of differential diversification rates among lineages were also investigated using both topological and Binary-State Speciation and Extinction methods. Key Results and Conclusions Floral glandular structures and especially trichomal elaiophores evolved multiple times independently in the American tribes of Iridoideae. The distribution pattern of species displaying glandular trichomes across the phylogeny reveals lability in the pollination system and suggests that these structures may have played a significant role in the diversification of the Iridoideae on the American continent. PMID:22782239

  14. Suppressive effect of wasabi (pungent Japanese spice) on gastric carcinogenesis induced by MNNG in rats.

    PubMed

    Tanida, N; Kawaura, A; Takahashi, A; Sawada, K; Shimoyama, T

    1991-01-01

    Dietary habits have been causally implicated in gastric carcinogenesis, whereas minor dietary items may also play a part. Wasabi is a popular pungent spice in Japanese meals. In this study the effect of wasabi on N-methyl-N'-nitro-N-nitrosoguanidine (MNNG)-induced gastric carcinogenesis was studied in rats. Wistar WKY male rats received drinking water containing 50 micrograms/ml of MNNG or tap water alone and a basal diet (PCE-2) or PCE-2 containing 10% (wt/wt) of wasabi powder for 40 weeks. Thus, three groups were completed as MNNG + PCE-2 (n = 30), MNNG + wasabi (n = 30), and tap water + wasabi (n = 30). At autopsy, nine rats (30%) had seven glandular stomach tumors (2 adenocarcinomas, 2 adenomatous polyps, and 3 adenomatous glandular hyperplasias) and three duodenal adenocarcinomas in the MNNG + PCE-2 group, whereas in the MNNG + wasabi group, two rats (7%) had one forestomach epidermoid cyst and one duodenal carcinosarcoma (corrected chi 2 = 4.63, p less than 0.05 for incidences of glandular stomach tumors between 2 groups). In addition, two rats had microscopic atypical glands in the MNNG + PCE-2 group. There was no tumor in the tap water + wasabi group. These results indicated that glandular stomach carcinogenesis induced by MNNG was suppressed by the administration of wasabi.

  15. Comparative ecomorphology of the cyathial nectaries in eight European Euphorbia species.

    PubMed

    Papp, Nóra; Csete, S; Farkas, Agnes

    2013-03-01

    The morphology and histology of the cyathial nectary were studied in 8 European leafy spurge (Euphorbia) species, revealing that certain histological traits of the glands are in close correlation to each species' habitat, underlining the importance of morphological evidences in determining relevant ecological tolerance spectra of plants.The structure of the cyathial glands was studied in longitudinal sections with light microscopy, and histological parameters were measured and statistically analyzed by appropriate softwares.The nectaries consist of a cuticle-covered epidermis, formed by palisade cells, under which the glandular tissue and parenchyma are composed of isodiametric and anisodiametric cells in all species. Thickness of cuticle, position of nectary stomata and number of rows comprising the glandular tissue vary to a great extent in plants living in xeric, humid or mesic habitats.Although all the studied anatomical features of the nectaries were expected to be in correspondence with the characteristics of habitat types, we have only found the number of glandular cell rows to be in strong correlation with the Ellenberg's ecological indicator values on soil moisture, which varied with species. The recorded anatomical differences among the studied Euphorbia taxa emphasize the ecological significance of glandular tissue in plant adaptation, which can also be relevant for systematic purposes.

  16. Exposure to Hexavalent Chromium Resulted in Significantly Higher Tissue Chromium Burden Compared With Trivalent Chromium Following Similar Oral Doses to Male F344/N Rats and Female B6C3F1 Mice

    PubMed Central

    Collins, Bradley J.; Stout, Matthew D.; Levine, Keith E.; Kissling, Grace E.; Fennell, Timothy R.; Walden, Ramsey; Abdo, Kamal; Pritchard, John B.; Fernando, Reshan A.; Burka, Leo T.; Hooth, Michelle J.

    2010-01-01

    In National Toxicology Program 2-year studies, hexavalent chromium [Cr(VI)] administered in drinking water was clearly carcinogenic in male and female rats and mice, resulting in small intestine epithelial neoplasms in mice at a dose equivalent to or within an order of magnitude of human doses that could result from consumption of chromium-contaminated drinking water, assuming that dose scales by body weight3/4 (body weight raised to the 3/4 power). In contrast, exposure to trivalent chromium [Cr(III)] at much higher concentrations may have been carcinogenic in male rats but was not carcinogenic in mice or female rats. As part of these studies, total chromium was measured in tissues and excreta of additional groups of male rats and female mice. These data were used to infer the uptake and distribution of Cr(VI) because Cr(VI) is reduced to Cr(III) in vivo, and no methods are available to speciate tissue chromium. Comparable external doses resulted in much higher tissue chromium concentrations following exposure to Cr(VI) compared with Cr(III), indicating that a portion of the Cr(VI) escaped gastric reduction and was distributed systemically. Linear or supralinear dose responses of total chromium in tissues were observed following exposure to Cr(VI), indicating that these exposures did not saturate gastric reduction capacity. When Cr(VI) exposure was normalized to ingested dose, chromium concentrations in the liver and glandular stomach were higher in mice, whereas kidney concentrations were higher in rats. In vitro studies demonstrated that Cr(VI), but not Cr(III), is a substrate of the sodium/sulfate cotransporter, providing a partial explanation for the greater absorption of Cr(VI). PMID:20843897

  17. Exposure to hexavalent chromium resulted in significantly higher tissue chromium burden compared with trivalent chromium following similar oral doses to male F344/N rats and female B6C3F1 mice.

    PubMed

    Collins, Bradley J; Stout, Matthew D; Levine, Keith E; Kissling, Grace E; Melnick, Ronald L; Fennell, Timothy R; Walden, Ramsey; Abdo, Kamal; Pritchard, John B; Fernando, Reshan A; Burka, Leo T; Hooth, Michelle J

    2010-12-01

    In National Toxicology Program 2-year studies, hexavalent chromium [Cr(VI)] administered in drinking water was clearly carcinogenic in male and female rats and mice, resulting in small intestine epithelial neoplasms in mice at a dose equivalent to or within an order of magnitude of human doses that could result from consumption of chromium-contaminated drinking water, assuming that dose scales by body weight(3/4) (body weight raised to the 3/4 power). In contrast, exposure to trivalent chromium [Cr(III)] at much higher concentrations may have been carcinogenic in male rats but was not carcinogenic in mice or female rats. As part of these studies, total chromium was measured in tissues and excreta of additional groups of male rats and female mice. These data were used to infer the uptake and distribution of Cr(VI) because Cr(VI) is reduced to Cr(III) in vivo, and no methods are available to speciate tissue chromium. Comparable external doses resulted in much higher tissue chromium concentrations following exposure to Cr(VI) compared with Cr(III), indicating that a portion of the Cr(VI) escaped gastric reduction and was distributed systemically. Linear or supralinear dose responses of total chromium in tissues were observed following exposure to Cr(VI), indicating that these exposures did not saturate gastric reduction capacity. When Cr(VI) exposure was normalized to ingested dose, chromium concentrations in the liver and glandular stomach were higher in mice, whereas kidney concentrations were higher in rats. In vitro studies demonstrated that Cr(VI), but not Cr(III), is a substrate of the sodium/sulfate cotransporter, providing a partial explanation for the greater absorption of Cr(VI).

  18. Integrating prior information into microwave tomography part 2: Impact of errors in prior information on microwave tomography image quality.

    PubMed

    Kurrant, Douglas; Fear, Elise; Baran, Anastasia; LoVetri, Joe

    2017-12-01

    The authors have developed a method to combine a patient-specific map of tissue structure and average dielectric properties with microwave tomography. The patient-specific map is acquired with radar-based techniques and serves as prior information for microwave tomography. The impact that the degree of structural detail included in this prior information has on image quality was reported in a previous investigation. The aim of the present study is to extend this previous work by identifying and quantifying the impact that errors in the prior information have on image quality, including the reconstruction of internal structures and lesions embedded in fibroglandular tissue. This study also extends the work of others reported in literature by emulating a clinical setting with a set of experiments that incorporate heterogeneity into both the breast interior and glandular region, as well as prior information related to both fat and glandular structures. Patient-specific structural information is acquired using radar-based methods that form a regional map of the breast. Errors are introduced to create a discrepancy in the geometry and electrical properties between the regional map and the model used to generate the data. This permits the impact that errors in the prior information have on image quality to be evaluated. Image quality is quantitatively assessed by measuring the ability of the algorithm to reconstruct both internal structures and lesions embedded in fibroglandular tissue. The study is conducted using both 2D and 3D numerical breast models constructed from MRI scans. The reconstruction results demonstrate robustness of the method relative to errors in the dielectric properties of the background regional map, and to misalignment errors. These errors do not significantly influence the reconstruction accuracy of the underlying structures, or the ability of the algorithm to reconstruct malignant tissue. Although misalignment errors do not significantly impact the quality of the reconstructed fat and glandular structures for the 3D scenarios, the dielectric properties are reconstructed less accurately within the glandular structure for these cases relative to the 2D cases. However, general agreement between the 2D and 3D results was found. A key contribution of this paper is the detailed analysis of the impact of prior information errors on the reconstruction accuracy and ability to detect tumors. The results support the utility of acquiring patient-specific information with radar-based techniques and incorporating this information into MWT. The method is robust to errors in the dielectric properties of the background regional map, and to misalignment errors. Completion of this analysis is an important step toward developing the method into a practical diagnostic tool. © 2017 American Association of Physicists in Medicine.

  19. Effect of anticholinesterase agents on airway epithelial function. Annual report, 15 July 1888-14 August 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marin, M.G.

    1989-09-15

    Irreversible anticholinesterase compounds have potential serious health effects when employed as chemical warfare agents. Intoxication with these agents will cause an accumulation of acetylcholine at nerve muscle and nerve-gland junctions. Because tracheal glands have rich cholinergic innervation, we hypothesized that exposure to anticholinesterase agents, such as soman, would stimulate glandular secretion. This would cause pathological changes in the important lung defense mechanism of mucociliary clearance. Initial work on this contract revealed a dose-related increase in mucociliary transport in the ferret in response to soman. This effect could be inhibited by atropine but not by pralidoxime. The investigation described in thismore » report relates to the effects of soman and its antidotes on glycoconjugate secretion of ferret trachea in vitro.« less

  20. PHARMACOGNOSTIC EVALUATION OF THE LEAF OF Rhus succedanea VAR. HIMALAICA. J. D HOOKER.

    PubMed Central

    Khan, Shafqat Ali; Ibrar, Muhammad; Barkatullah

    2016-01-01

    Background: Rhus succedanea is generally traded, distributed and sold in the markets in its crude and raw form. This may have been mixed with adulterants, mismanaged by malpractices and substituted with other closely related drugs having different effect. This study is therefore carried out to authenticate the plant through pharmacogonostic evaluations. Material & Methods: The organoleptic studies were carried through sensory organs i.e size, shape, texrure, odour, etc. Histological studies were conducted by preparing hand slides, mounting the specimen in potato tuber; fluorescence characters were determined through UV and phytochemical screening was investigated using various standard and common methods from relevant literature. Results: Morphologically, the Rhus is a perennial small sized deciduous tree, 5–9 m tall with opposite imparipinnately compound leaves and small grayish yellow flowers born on paniculate inflorescence; locally, called as Rakhkal in Pashto and Kakarsingi in Urdu. The organoleptic evaluation showed leaf had pleasant, aromatic odour and astringent taste. Transverse section of leaf through midrib region was worked out. The anatomy of the midrib has shown to be surrounded by both upper and lower epidermis with multicellular non-glandular trichomes. The leaf was hypostomatic showing anomocytic stomata with average stomatal number 27.1 ± 7.2 and stomatal index 14 ± 3.63. The average vein islet, vein termination and palisade ratios were 13.6 ± 3.04, 10.21 ± 1.92 and 6 ± 2.01 respectively. Leaf powder showed the existance of anomocytic stomata, spirally thickened xylem vessels, non-glandular multicellular and stellate trichomes. Fluorescence study and percent extractive values was also carried out. The phytochemical screening showed the presence of carbohydrates, protein, alkaloids, phenols, flavonoids, terpenoids and anthraquenones, while tannins and fixed oil was not detected. Quantitatively highest amount of alkaloids 16% and flavonoids 19% in leaf was detected. Conclusion: The results of the of the anatomical, organoleptic and physiochemical studies of the powder of leaf will be helpful in standardization of R. succedanea the crude drug. PMID:28480367

  1. [In situ adenocarcinoma of the uterus cervix: difficulties of its cytohistological diagnosis].

    PubMed

    Tranbaloc, P

    2002-04-01

    In situ adenocarcinoma is regarded as the precursor of invasive adenocarcinoma. It is asymptomatic and early diagnosis relies solely on cytopathologist. It is usually discovered on a cone for squamous CIN. When diagnosis is made by biopsy, conisation is required to exclude invasive adenocarcinoma. Lesion is histologically characterised by epitheliomatous transformation of endocervical glands without invasion of the chorion. By the appearance of glandular cells, different histological varieties are described. They have no influence on the prognosis. Several benign lesions may mimic adenocarcinoma: tubal metaplasia, glandular atypia due to inflammation or irradiation, mesonephric remnants and microglandular hyperplasia. Precursor lesions (atypical hyperplasia, glandular dysplasia, CIGNI and II) are badly morphologically defined. Preferential location of in situ adenocarcinoma is the transformation zone. Because of this topography, if the surgical margins are disease free, conisation alone may be adequate therapy. HPV infection (mainly HPV 18) are incriminated in its pathogenesis.

  2. [Glandular papilloma of the right main bronchus. Detection of an exon 2 mutation of the KRAS gene (c.35G>A)].

    PubMed

    Wohlschläger, J; Welter, S; Stamatis, G; Theegarten, D; Hager, T; Mairinger, F; Worm, K; Schmid, K W; Müller, K M

    2013-07-01

    Benign epithelial tumors of the tracheobronchial system and the lungs are exceedingly rare. These entities encompass squamous and glandular papillomas (as well as their mixed forms) and adenomas (alveolar adenoma, papillary adenoma, salivary gland-like pleomorphic and mucinous adenomas and mucinous cystadenomas). These tumors are considered to be biologically benign neoplasms; however, they can pose considerable diagnostic difficulties, especially during frozen section evaluation, as they can mimic malignant tumors and in particular they can resemble well differentiated papillary adenocarcinomas. As a result of the extreme rarity of these tumors only a few descriptive diagnostic series exist and a systematic investigation including molecular data does not exist. This article presents the case of a 64-year-old patient with a glandular papilloma of the right main bronchus including the immunohistochemical and molecular work-up as well as a review of the current literature.

  3. Animal model of acid-reflux esophagitis: pathogenic roles of acid/pepsin, prostaglandins, and amino acids.

    PubMed

    Takeuchi, Koji; Nagahama, Kenji

    2014-01-01

    Esophagitis was induced in rats within 3 h by ligating both the pylorus and transitional region between the forestomach and glandular portion under ether anesthesia. This esophageal injury was prevented by the administration of acid suppressants and antipepsin drug and aggravated by exogenous pepsin. Damage was also aggravated by pretreatment with indomethacin and the selective COX-1 but not COX-2 inhibitor, whereas PGE2 showed a biphasic effect depending on the dose; a protection at low doses, and an aggravation at high doses, with both being mediated by EP1 receptors. Various amino acids also affected this esophagitis in different ways; L-alanine and L-glutamine had a deleterious effect, while L-arginine and glycine were highly protective, both due to yet unidentified mechanisms. It is assumed that acid/pepsin plays a major pathogenic role in this model of esophagitis; PGs derived from COX-1 are involved in mucosal defense of the esophagus; and some amino acids are protective against esophagitis. These findings also suggest a novel therapeutic approach in the treatment of esophagitis, in addition to acid suppressant therapy. The model introduced may be useful to test the protective effects of drugs on esophagitis and investigate the mucosal defense mechanism in the esophagus.

  4. Gastric emptying after artificial ulceration in rats: differences due to the site of the ulcer and the effects of prokinetic drugs.

    PubMed

    Uchida, Masayuki; Kobayashi, Orie; Shimizu, Kimiko

    2017-01-01

    Background This study aimed to evaluate the effects of the position of an acetic acid-induced gastric ulcer and the effects of prokinetic drugs on gastric emptying. Materials and Methods Male Sprague-Dawley rats were used in this study. Acetic acid ulcers were induced either in the region between the fundus and pylorus on the anterior wall of the stomach or in the glandular region on the greater curvature of the stomach to determine whether there were regional differences in the effect of the ulcers. Gastric emptying was evaluated with a breath test using [1- 13 C] acetic acid. In addition, the effects of the prokinetic drugs, metoclopramide and mosapride, on gastric emptying were also evaluated. Results Acetic acid induced ulcers in the region between the fundus and pylorus on the anterior wall of the stomach significantly delayed gastric emptying as compared with control rats, but not the acetic acid induced ulcers in the glandular region on the greater curvature of the stomach. Metoclopramide and mosapride did not improve the delayed gastric emptying even at doses that enhanced gastric emptying in normal rats. Conclusion These findings show that gastric emptying is influenced by the position of the ulcer and the region between the fundus and pylorus on the anterior wall plays an important role in gastric emptying. Moreover, it was found that metoclopramide and mosapride do not improve the delayed gastric emptying caused by acetic acid ulcers induced on the anterior wall in the region between the fundus and pylorus.

  5. Gastric emptying after artificial ulceration in rats: differences due to the site of the ulcer and the effects of prokinetic drugs

    PubMed Central

    Uchida, Masayuki; Kobayashi, Orie; Shimizu, Kimiko

    2017-01-01

    Abstract Background This study aimed to evaluate the effects of the position of an acetic acid-induced gastric ulcer and the effects of prokinetic drugs on gastric emptying. Materials and Methods Male Sprague-Dawley rats were used in this study. Acetic acid ulcers were induced either in the region between the fundus and pylorus on the anterior wall of the stomach or in the glandular region on the greater curvature of the stomach to determine whether there were regional differences in the effect of the ulcers. Gastric emptying was evaluated with a breath test using [1-13C] acetic acid. In addition, the effects of the prokinetic drugs, metoclopramide and mosapride, on gastric emptying were also evaluated. Results Acetic acid induced ulcers in the region between the fundus and pylorus on the anterior wall of the stomach significantly delayed gastric emptying as compared with control rats, but not the acetic acid induced ulcers in the glandular region on the greater curvature of the stomach. Metoclopramide and mosapride did not improve the delayed gastric emptying even at doses that enhanced gastric emptying in normal rats. Conclusion These findings show that gastric emptying is influenced by the position of the ulcer and the region between the fundus and pylorus on the anterior wall plays an important role in gastric emptying. Moreover, it was found that metoclopramide and mosapride do not improve the delayed gastric emptying caused by acetic acid ulcers induced on the anterior wall in the region between the fundus and pylorus. PMID:28652516

  6. Transcriptional profiling unravels potential metabolic activities of the olive leaf non-glandular trichome

    PubMed Central

    Koudounas, Konstantinos; Manioudaki, Maria E.; Kourti, Anna; Banilas, Georgios; Hatzopoulos, Polydefkis

    2015-01-01

    The olive leaf trichomes are multicellular peltate hairs densely distributed mainly at the lower leaf epidermis. Although, non-glandular, they have gained much attention since they significantly contribute to abiotic and biotic stress tolerance of olive leaves. The exact mechanisms by which olive trichomes achieve these goals are not fully understood. They could act as mechanical barrier but they also accumulate high amounts of flavonoids among other secondary metabolites. However, little is currently known about the exact compounds they produce and the respective metabolic pathways. Here we present the first EST analysis from olive leaf trichomes by using 454-pyrosequencing. A total of 5368 unigenes were identified out of 7258 high quality reads with an average length of 262 bp. Blast search revealed that 27.5% of them had high homologies to known proteins. By using Blast2GO, 1079 unigenes (20.1%) were assigned at least one Gene Ontology (GO) term. Most of the genes were involved in cellular and metabolic processes and in binding functions followed by catalytic activity. A total of 521 transcripts were mapped to 67 KEGG pathways. Olive trichomes represent a tissue of highly unique transcriptome as per the genes involved in developmental processes and the secondary metabolism. The results indicate that mature olive trichomes are trancriptionally active, mainly through the potential production of enzymes that contribute to phenolic compounds with important roles in biotic and abiotic stress responses. PMID:26322070

  7. Evaluation of transurethral and transperineal tin ethyl etiopurpurin-photodynamic therapy on the canine prostate one week after drug injection

    NASA Astrophysics Data System (ADS)

    Selman, Steven H.; Keck, Rick W.; Kondo, Sandy; Albrecht, Detlef

    1999-06-01

    We have been investigating the potential applicability of photodynamic therapy for the treatment of benign and malignant disease of the prostate. Both transurethral and transperineal approaches to the delivery of light to the tin ethyl etiopurpurin sensitized canine prostate have been studied. Pharmacologic studies were performed and suggested that delaying light treatment for 7 days after drug administration would maximize the desired effect on the targeted prostatic tissue while minimizing the damage to surrounding bladder and rectum. A total of 12 dogs were treated with transurethral light alone (n=6) or the combination of transurethral light and transperineal light one week after tin ethyl etiopurpurin administration. (Previous studies have shown that light alone has no effect on prostate size or histology.) Animals were euthanized 48 hours and 3 weeks after completion of treatment (drug, 1mg/kg day 0, light [400mw/750sec]day 7). Tissue response was determined by gross and microscopic examination. Additionally, pre- and post- treatment transrectal ultrasounds were compared to assess changes in prostate volume and tissue echogenicity. The combination of transurethral and transperineal light results in extensive destruction of glandular epithelium with minimal damage to surrounding structures. Prostate volumes decreased by an average of 52%. Untreated areas were found to lie greater than 0.5 cm from the light diffuser. These studies have encouraged us to continue to investigate this modality as a technique for total ablation of prostatic glandular epithelium.

  8. Optical Coherence Tomography of the Labial Salivary Glands Reveals Age‐Related Differences in Women

    PubMed Central

    Grulkowski, Ireneusz; Karnowski, Karol; Wojtkowski, Maciej; Walkowiak, Jaroslaw

    2015-01-01

    Abstract The labial minor salivary glands (LSGs) play a role in medical research and practice due to their superficial location and involvement in both systemic and localized diseases. Swept‐source optical coherence tomography (OCT) is a noninvasive modality that enables in vivo, micrometer resolution, wide‐field three‐dimensional imaging in seconds. A purpose‐built swept‐source OCT instrument was employed to acquire three‐dimensional datasets covering the area of 2.43 cm2 of the mucosa of the lower lip to the depth of 3.4 mm in young (n = 14; mean age ± SD: 27 ± 3 years; body mass index [BMI] 20.4 ± 2.3 kg/m2) and middle‐aged women (n = 11; 54 ± 6 years; 25.5 ± 3.2 kg/m2). Glandular tissue reflectivity mode (range 0–255; 86 ± 17 vs. 68 ± 12, p = 0.005), average single LSG area in tissue sample (5.26 ± 2.62 mm2 vs. 2.87 ± 1.26 mm2, p = 0.011), and LSG surface filling factor (0.23 ± 0.13 vs. 0.11 ± 0.10, p = 0.027) had higher values in younger than in middle‐aged women. A correlation between BMI and glandular tissue reflectivity mode (Spearman's ρ = –0.60) was found (p = 0.002). The results highlight the potential value of LSGs’ OCT morphometry in research regarding ageing. PMID:26530049

  9. Severe glandular tularemia in a patient treated with anti-tumour necrosis factor for psoriatic arthritis.

    PubMed

    Calin, Ruxandra; Caumes, Eric; Reibel, Florence; Ali Mohamed, Anzime; Brossier, Florence; Foltz, Violaine; Boussouar, Samia; Fautrel, Bruno; Maurin, Max; Katlama, Christine; Pourcher, Valérie

    2017-07-01

    A case of severe glandular tularemia in a patient receiving anti-tumour necrosis factor (TNF) therapy is reported here. The patient required prolonged treatment with doxycycline-ciprofloxacin due to early relapse after ciprofloxacin was stopped. Tularemia may have a more severe course in patients receiving anti-TNF. This may thus be an indication for more aggressive treatment. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Mayolenes: Labile defensive lipids from the glandular hairs of a caterpillar (Pieris rapae)

    PubMed Central

    Smedley, Scott R.; Schroeder, Frank C.; Weibel, Douglas B.; Meinwald, Jerrold; Lafleur, Katie A.; Renwick, J. Alan; Rutowski, Ronald; Eisner, Thomas

    2002-01-01

    Larvae of the European cabbage butterfly, Pieris rapae (Pieridae), are beset with glandular hairs, bearing droplets of a clear oily secretion at their tip. The fluid consists primarily of a series of chemically labile, unsaturated lipids, the mayolenes, which are derived from 11-hydroxylinolenic acid. In bioassays with the ant Crematogaster lineolata, the secretion was shown to be potently deterrent, indicating that the fluid plays a defensive role in nature. PMID:11997469

  11. Primary cutaneous adenosquamous carcinoma of the penis: the first characterization of HPV status in this rare and diagnostically challenging entity with review of glandular carcinomas of the penis.

    PubMed

    Rush, P S; Shiau, J M; Hibler, B P; Longley, B J; Downs, T M; Bennett, D D

    2016-12-01

    Glandular and pseudoglandular tumors of the penile skin are extremely uncommon and can present diagnostic challenges. Primary adenosquamous carcinoma of the penis is an extremely rare tumor, composed of distinct areas of malignant squamous and glandular cells, making it a diagnostically challenging entity. The World Health Organization (WHO) recognizes several subtypes of squamous cell carcinoma (SCC), each with its own distinctive pathologic appearance, clinical associations and prognosis. Among these variants is the exceedingly uncommon adenosquamous carcinoma (ASC), representing 1%-2% of all SCC of the penis. Recent large studies have interrogated the presence of human papillomavirus (HPV) in malignant penile tumors and have shown specific morphologic patterns and clinical presentations to associate with HPV status. However, given the rarity of the adenosquamous variant of SCC, it has largely been excluded from these studies. The glandular components of these lesions can present a confusing appearance, particularly when a large tumor is represented on a small biopsy. Here we describe a difficult histologic presentation of this rare tumor, with the first published characterization of the HPV status of this subtype. This case represents a distinctly unusual case of metastatic HPV-positive primary cutaneous adenosquamous carcinoma of the penis. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Cupping artifact correction and automated classification for high-resolution dedicated breast CT images.

    PubMed

    Yang, Xiaofeng; Wu, Shengyong; Sechopoulos, Ioannis; Fei, Baowei

    2012-10-01

    To develop and test an automated algorithm to classify the different tissues present in dedicated breast CT images. The original CT images are first corrected to overcome cupping artifacts, and then a multiscale bilateral filter is used to reduce noise while keeping edge information on the images. As skin and glandular tissues have similar CT values on breast CT images, morphologic processing is used to identify the skin mask based on its position information. A modified fuzzy C-means (FCM) classification method is then used to classify breast tissue as fat and glandular tissue. By combining the results of the skin mask with the FCM, the breast tissue is classified as skin, fat, and glandular tissue. To evaluate the authors' classification method, the authors use Dice overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on eight patient images. The correction method was able to correct the cupping artifacts and improve the quality of the breast CT images. For glandular tissue, the overlap ratios between the authors' automatic classification and manual segmentation were 91.6% ± 2.0%. A cupping artifact correction method and an automatic classification method were applied and evaluated for high-resolution dedicated breast CT images. Breast tissue classification can provide quantitative measurements regarding breast composition, density, and tissue distribution.

  13. Cupping artifact correction and automated classification for high-resolution dedicated breast CT images

    PubMed Central

    Yang, Xiaofeng; Wu, Shengyong; Sechopoulos, Ioannis; Fei, Baowei

    2012-01-01

    Purpose: To develop and test an automated algorithm to classify the different tissues present in dedicated breast CT images. Methods: The original CT images are first corrected to overcome cupping artifacts, and then a multiscale bilateral filter is used to reduce noise while keeping edge information on the images. As skin and glandular tissues have similar CT values on breast CT images, morphologic processing is used to identify the skin mask based on its position information. A modified fuzzy C-means (FCM) classification method is then used to classify breast tissue as fat and glandular tissue. By combining the results of the skin mask with the FCM, the breast tissue is classified as skin, fat, and glandular tissue. To evaluate the authors’ classification method, the authors use Dice overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on eight patient images. Results: The correction method was able to correct the cupping artifacts and improve the quality of the breast CT images. For glandular tissue, the overlap ratios between the authors’ automatic classification and manual segmentation were 91.6% ± 2.0%. Conclusions: A cupping artifact correction method and an automatic classification method were applied and evaluated for high-resolution dedicated breast CT images. Breast tissue classification can provide quantitative measurements regarding breast composition, density, and tissue distribution. PMID:23039675

  14. Genetic Architecture of Capitate Glandular Trichome Density in Florets of Domesticated Sunflower (Helianthus annuus L.)

    PubMed Central

    Gao, Qing-Ming; Kane, Nolan C.; Hulke, Brent S.; Reinert, Stephan; Pogoda, Cloe S.; Tittes, Silas; Prasifka, Jarrad R.

    2018-01-01

    Capitate glandular trichomes (CGT), one type of glandular trichomes, are most common in Asteraceae species. CGT can produce various secondary metabolites such as sesquiterpene lactones (STLs) and provide durable resistance to insect pests. In sunflower, CGT-based host resistance is effective to combat the specialist pest, sunflower moth. However, the genetic basis of CGT density is not well understood in sunflower. In this study, we identified two major QTL controlling CGT density in sunflower florets by using a F4 mapping population derived from the cross HA 300 × RHA 464 with a genetic linkage map constructed from genotyping-by-sequencing data and composed of 2121 SNP markers. One major QTL is located on chromosome 5, which explained 11.61% of the observed phenotypic variation, and the second QTL is located on chromosome 6, which explained 14.06% of the observed phenotypic variation. The QTL effects and the association between CGT density and QTL support interval were confirmed in a validation population which included 39 sunflower inbred lines with diverse genetic backgrounds. We also identified two strong candidate genes in the QTL support intervals, and the functions of their orthologs in other plant species suggested their potential roles in regulating capitate glandular trichome density in sunflower. Our results provide valuable information to sunflower breeding community for developing host resistance to sunflower insect pests. PMID:29375602

  15. Evidence of protocarnivory in triggerplants (Stylidium spp.; Stylidiaceae).

    PubMed

    Darnowski, D W; Carroll, D M; Płachno, B; Kabanoff, E; Cinnamon, E

    2006-11-01

    Australian triggerplants (Stylidium spp.; Stylidiaceae) trap small insects using mucilage-secreting glandular hairs held at various points on their inflorescence stems and flower parts. Triggerplants are generally found in habitats also containing genera of plants already accepted as carnivorous, two of which (Drosera, Byblis) use the same basic mechanism as Stylidium to trap their prey. In the herbarium, sheets of triggerplants and of accepted groups of carnivorous plants held similar numbers of trapped insects, and in the field, trapping of small prey per unit of glandular surface area was the same at a given site for triggerplants and for nearby carnivorous plants at three sites in northern Australia. Even more important, protease activity was produced by glandular regions of both triggerplants and Drosera after induction with yeast extract. A panel of negative and positive controls, including use 1) of plants grown in tissue culture, which therefore lack surface microorganisms, and 2) of protease inhibitors, shows that this activity 1) is generated by the glandular regions of the triggerplant itself, not by organisms that might reside on the surface of the plants, and 2) is due to proteases. All of this evidence taken together provides strong evidence of protocarnivory in Stylidium, something not previously suggested in the scientific literature, though the insect trapping has been noted informally. Experiments remain to be done to determine nutrient uptake, so triggerplants may well be fully carnivorous.

  16. 3D bioprinting matrices with controlled pore structure and release function guide in vitro self-organization of sweat gland.

    PubMed

    Liu, Nanbo; Huang, Sha; Yao, Bin; Xie, Jiangfan; Wu, Xu; Fu, Xiaobing

    2016-10-03

    3D bioprinting matrices are novel platforms for tissue regeneration. Tissue self-organization is a critical process during regeneration that implies the features of organogenesis. However, it is not clear from the current evidences whether 3D printed construct plays a role in guiding tissue self-organization in vitro. Based on our previous study, we bioprinted a 3D matrix as the restrictive niche for direct sweat gland differentiation of epidermal progenitors by different pore structure (300-μm or 400-μm nozzle diameters printed) and reported a long-term gradual transition of differentiated cells into glandular morphogenesis occurs within the 3D construct in vitro. At the initial 14-day culture, an accelerated cell differentiation was achieved with inductive cues released along with gelatin reduction. After protein release completed, the 3D construct guide the self-organized formation of sweat gland tissues, which is similar to that of the natural developmental process. However, glandular morphogenesis was only observed in 300-μm-printed constructs. In the absence of 3D architectural support, glandular morphogenesis was not occurred. This striking finding made us to identify a previously unknown role of the 3D-printed structure in glandular tissue regeneration, and this self-organizing strategy can be applied to forming other tissues in vitro.

  17. Modification in digestive processing strategies to reduce toxic trace metal uptake in a marine bivalve

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Decho, A.W.; Luoma, S.N.

    1994-12-31

    Bivalves possess two major digestion pathways for processing food particles: a rapid ``intestinal`` pathway where digestion is largely extracellular; and a slower ``glandular`` pathway where digestion is largely intracellular. The slower glandular pathway often results in more efficient absorption of carbon but also more efficient uptake of certain metals (e.g. Cr associated with bacteria). In the bivalve Potamocorbula amurensis, large portions (> 90%) of bacteria are selectively routed to the glandular pathway. This results in efficient C uptake but also efficient uptake of associated Cr. The authors further determined if prolonged exposure to Cr-contaminated bacteria would result in high Crmore » uptake by animals or whether mechanisms exist to reduce Cr exposure and uptake. Bivalves were exposed to natural food + added bacteria (with or without added Cr) for a 6-day period, then pulse-chase experiments were conducted to quantify digestive processing and % absorption efficiencies (%AE) of bacterial Cr. Bivalves compensate at low (2--5 ug/g sed) Cr by reducing overall food ingestion, while digestive processing of food remains statistically similar to controls. At high Cr (200--500 ug/g sed) there are marked decreases in % bacteria processed by glandular digestion. This results in lower overall %AE of Cr. The results suggest that bivalves under natural conditions might balance efficient carbon sequestration against avoiding uptake of potentially toxic metals associated the food.« less

  18. Quantification of breast density with spectral mammography based on a scanned multi-slit photon-counting detector: A feasibility study

    PubMed Central

    Ding, Huanjun; Molloi, Sabee

    2012-01-01

    Purpose A simple and accurate measurement of breast density is crucial for the understanding of its impact in breast cancer risk models. The feasibility to quantify volumetric breast density with a photon-counting spectral mammography system has been investigated using both computer simulations and physical phantom studies. Methods A computer simulation model involved polyenergetic spectra from a tungsten anode x-ray tube and a Si-based photon-counting detector has been evaluated for breast density quantification. The figure-of-merit (FOM), which was defined as the signal-to-noise ratio (SNR) of the dual energy image with respect to the square root of mean glandular dose (MGD), was chosen to optimize the imaging protocols, in terms of tube voltage and splitting energy. A scanning multi-slit photon-counting spectral mammography system has been employed in the experimental study to quantitatively measure breast density using dual energy decomposition with glandular and adipose equivalent phantoms of uniform thickness. Four different phantom studies were designed to evaluate the accuracy of the technique, each of which addressed one specific variable in the phantom configurations, including thickness, density, area and shape. In addition to the standard calibration fitting function used for dual energy decomposition, a modified fitting function has been proposed, which brought the tube voltages used in the imaging tasks as the third variable in dual energy decomposition. Results For an average sized breast of 4.5 cm thick, the FOM was maximized with a tube voltage of 46kVp and a splitting energy of 24 keV. To be consistent with the tube voltage used in current clinical screening exam (~ 32 kVp), the optimal splitting energy was proposed to be 22 keV, which offered a FOM greater than 90% of the optimal value. In the experimental investigation, the root-mean-square (RMS) error in breast density quantification for all four phantom studies was estimated to be approximately 1.54% using standard calibration function. The results from the modified fitting function, which integrated the tube voltage as a variable in the calibration, indicated a RMS error of approximately 1.35% for all four studies. Conclusions The results of the current study suggest that photon-counting spectral mammography systems may potentially be implemented for an accurate quantification of volumetric breast density, with an RMS error of less than 2%, using the proposed dual energy imaging technique. PMID:22771941

  19. Human glans penis augmentation using injectable hyaluronic acid gel.

    PubMed

    Kim, J J; Kwak, T I; Jeon, B G; Cheon, J; Moon, D G

    2003-12-01

    Although augmentation phalloplasty is not an established procedure, some patients still need enlargement of their penis. Current penile augmentation is girth enhancement of penile body by dermofat graft. We performed this study to identify the efficacy and the patient's satisfaction of human glans penis augmentation with injectable hyaluronic acid gel. In 100 patients of subjective small penis (Group I) and 87 patients of small glans after dermofat graft (Group II), 2 cm(3) of hyaluronic acid gel was injected into the glans penis, subcutaneously. At 1 y after injection, changes of glandular diameter were measured by tapeline. Patient's visual estimation of glandular size (Gr 0-4) and patient's satisfaction (Grade (Gr) 0-4) were evaluated, respectively. Any adverse reactions were also evaluated. The mean age of patients was 42.2 (30-70) y in Group I and 42.13 (28-61) y in Group II. The maximal glandular circumference was significantly increased compared to basal circumference of 9.13+/-0.64 cm in Group I (P<0.01) and 9.49+/-1.05 cm in Group II (P<0.01) at 1 y after injection. Net increase of maximal glandular circumference after glans augmentation was 14.93+/-0.80 mm in Group I and 14.78+/-0.89 mm in Group II. In patient's visual estimation, more than 50% of injected volume was maintained in 95% of Group 1 and 100% of Group II. The percentage of postoperative satisfaction (Gr 4, 5) was 77% in Group 1 and 69% in Group II. There was no abnormal reaction in area feeling, texture, and color. In most cases, initial discoloration by glandular swelling recovered to normal within 2 weeks. There were no signs of inflammation and no serious adverse reactions in all cases. These results suggest that injectable hyaluronic acid gel is a safe and effective material for augmentation of glans penis.

  20. [Precancerous lesions of the uterine cervix: morphology and molecular pathology].

    PubMed

    Horn, L-C; Klostermann, K

    2011-11-01

    HPV-induced alterations of the uterine cervix are frequently biopsied because of suspicious findings on a Pap smear and/or colposcopy. Precancerous lesions occur at the so called transformation zone. For those representing squamous differentiation, the traditional three-tier grading system in CIN 1 to 3 is used. CIN 1 and CIN 2 represent (spontaneous) regression in 60-90% and 50%, respectively. In CIN 3 lesions progression is seen in 20-50%. For appropriate grading, improvement of inter- and intraobserver correlation as well as the exclusion of non-precancerous lesions, p16 immunohistochemistry might be helpful. The terms endocervical glandular dysplasia and low-grade glandular intraepithelial neoplasia have been suggested for glandular lesions less than adenocarcinoma in situ (AIS). Until now reproducible histological criteria have not been established. Additional studies using HPV analysis, p16 and Ki-67 immunohistochemistry have not been proved for these lesions. In accordance with international consensus meetings, these diagnostic terms are not recommended for use in practice. AIS, characterised by the replacement of glandular epithelium by cytologically malignant cells, has been established as the precancerous lesion of the endocervix. AIS is much less common than CIN 3 with a reported range of 1:50-100. But, AIS is found in association with CIN 3 with 25-75%. The differential diagnosis between AIS and non-neoplastic glandular lesion may be aided by immunohistochemistry (e.g. p16, Ki-67, bcl-2, vimentin). All specimens obtained after the clinical diagnosis of cervical precancerous lesions should be examined using step sectioning to rule out microinvasive growth. Important information for clinicians includes the quality of the specimen (cautery artefacts, transformation zone enclosed within the probe), exact grading of CIN lesions, identification of other lesions responsible for suspicious findings of a Pap smear or at colposcopy, and in the case of conisation the distance of the lesion from the resection margins (endo- and ectocervical and circumferential margin).

  1. Quantitative differentiation of breast lesions at 3T diffusion-weighted imaging (DWI) using the ratio of distributed diffusion coefficient (DDC).

    PubMed

    Ertas, Gokhan; Onaygil, Can; Akin, Yasin; Kaya, Handan; Aribal, Erkin

    2016-12-01

    To investigate the accuracy of diffusion coefficients and diffusion coefficient ratios of breast lesions and of glandular breast tissue from mono- and stretched-exponential models for quantitative diagnosis in diffusion-weighted magnetic resonance imaging (MRI). We analyzed pathologically confirmed 170 lesions (85 benign and 85 malignant) imaged using a 3.0T MR scanner. Small regions of interest (ROIs) focusing on the highest signal intensity for lesions and also for glandular tissue of contralateral breast were obtained. Apparent diffusion coefficient (ADC) and distributed diffusion coefficient (DDC) were estimated by performing nonlinear fittings using mono- and stretched-exponential models, respectively. Coefficient ratios were calculated by dividing the lesion coefficient by the glandular tissue coefficient. A stretched exponential model provides significantly better fits then the monoexponential model (P < 0.001): 65% of the better fits for glandular tissue and 71% of the better fits for lesion. High correlation was found in diffusion coefficients (0.99-0.81 and coefficient ratios (0.94) between the models. The highest diagnostic accuracy was found by the DDC ratio (area under the curve [AUC] = 0.93) when compared with lesion DDC, ADC ratio, and lesion ADC (AUC = 0.91, 0.90, 0.90) but with no statistically significant difference (P > 0.05). At optimal thresholds, the DDC ratio achieves 93% sensitivity, 80% specificity, and 87% overall diagnostic accuracy, while ADC ratio leads to 89% sensitivity, 78% specificity, and 83% overall diagnostic accuracy. The stretched exponential model fits better with signal intensity measurements from both lesion and glandular tissue ROIs. Although the DDC ratio estimated by using the model shows a higher diagnostic accuracy than the ADC ratio, lesion DDC, and ADC, it is not statistically significant. J. Magn. Reson. Imaging 2016;44:1633-1641. © 2016 International Society for Magnetic Resonance in Medicine.

  2. Clinical significance of atypical glandular cells in Pap tests: An analysis of more than 3000 cases at a large academic women's center.

    PubMed

    Pradhan, Dinesh; Li, Zaibo; Ocque, Rebecca; Patadji, Stell; Zhao, Chengquan

    2016-08-01

    The interpretation of atypical glandular cells (AGC) in Papanicolaou (Pap) tests and screening for glandular neoplasia remain challenging. Pap tests with an AGC interpretation from January 2008 to December 2013 were retrieved from a pathology database, and cases with histologic follow-up within 1 year were included in the study. There were 589,830 Pap tests during the study period, and 3709 cases (0.6%) were reported as AGC, which included the following: AGC, not otherwise specified (52.0%); atypical endocervical cells (28.0%); and other categories. There were 3007 cases (81.1%) with histologic follow-up results within 1 year. Cervical intraepithelial neoplasia 2/3 (CIN2/3), cervical adenocarcinoma in situ (AIS)/adenocarcinoma, and endometrial carcinoma were identified in 5.6%, 1.9%, and 5.5% of cases, respectively. Glandular neoplasia was more likely to be identified in cases with pure AGC subcategories than cases with AGC and squamous abnormalities. Endometrial neoplasia was more likely to be identified in cases with atypical endometrial cells than other categories. Overall, the most common severe abnormality on histologic follow-up was CIN2/3. Although CIN2/3 was the most common severe lesion in patients younger than 30 years (10.0%) and in patients aged 30 to 49 years (6.4%), endometrial carcinoma was the most common lesion in women who were 50 years old or older (13.7%). Endocervical glandular lesions (AIS and adenocarcinoma) occurred in only 1.9% of women. AGC subtypes and ages significantly affect histological follow-up results; 90.5% of cases with carcinoma on histologic follow-up were either endometrial or metastatic carcinoma. This study supports the recommendation that women with AGC Pap test results should be followed up with both endocervical and endometrial sampling. Cancer Cytopathol 2016;124:589-95. © 2016 American Cancer Society. © 2016 American Cancer Society.

  3. Effect of Low-Dose Aspirin on Chronic Acid Reflux Esophagitis in Rats.

    PubMed

    Masuda, Takahiro; Yano, Fumiaki; Omura, Nobuo; Tsuboi, Kazuto; Hoshino, Masato; Yamamoto, Se Ryung; Akimoto, Shunsuke; Kashiwagi, Hideyuki; Yanaga, Katsuhiko

    2018-01-01

    Clinical role of low-dose aspirin (LDA) in pathogenesis of gastroesophageal reflux disease is by far controversial. This can be attributed to the paucity of basic research detailing the mechanism of LDA-induced esophageal mucosal injury (EI) on underlying chronic acid reflux esophagitis (RE). The aim of this study was to clarify the effect of LDA on chronic RE in rats. Esophagitis was induced in 8-week-old male Wistar rats by ligating the border between forestomach and glandular portion with a 2-0 silk tie and covering the duodenum with a small piece of 18-Fr Nélaton catheter. Seventy-eight chronic RE rat models were divided into five treatment groups, consisting of orally administered vehicle (controls), and aspirin doses of 2, 5, 50 or 100 mg/kg once daily for 28 days. EI was assessed by gross area of macroscopic mucosal injury, severity grade of esophagitis and microscopic depth of infiltration by inflammatory cells. Area of esophagitis in animals with aspirin dose of 100 mg/kg/day showed a 36.5% increase compared with controls, although it failed to achieve statistical significance (p = 0.812). Additionally, the rate of severe EI was increased in animals with aspirin dose of 100 mg/kg/day as compared with controls (p < 0.05). The grade of severity correlated with the depth of inflammation (r s  = 0.492, p < 0.001). Maximal dose aspirin (100 mg/kg/day) contributed in exacerbating preexisting EI. LDA (2 and 5 mg/kg/day), on the other hand, did not affect chronic RE in this model. LDA seems to be safe for use in patients with chronic RE.

  4. Considerations for applying VARSKIN mod 2 to skin dose calculations averaged over 10 cm2.

    PubMed

    Durham, James S

    2004-02-01

    VARSKIN Mod 2 is a DOS-based computer program that calculates the dose to skin from beta and gamma contamination either directly on skin or on material in contact with skin. The default area for calculating the dose is 1 cm2. Recently, the U.S. Nuclear Regulatory Commission issued new guidelines for calculating shallow dose equivalent from skin contamination that requires the dose be averaged over 10 cm2. VARSKIN Mod 2 was not filly designed to calculate beta or gamma dose estimates averaged over 10 cm2, even though the program allows the user to calculate doses averaged over 10 cm2. This article explains why VARSKIN Mod 2 overestimates the beta dose when applied to 10 cm2 areas, describes a manual method for correcting the overestimate, and explains how to perform reasonable gamma dose calculations averaged over 10 cm2. The article also describes upgrades underway in Varskin 3.

  5. Successful Excision of Gynecomastia with Nipple Repositioning Technique Utilizing the Dermoglandular Flap

    PubMed Central

    Motamed, Sadrollah; Hassanpour, Seyed Esmail; Moosavizadeh, Seyed Mehdi; Heidari, Ataollah; Rouientan, Abdoreza; Nazemian, Mahmood

    2015-01-01

    There are many surgical techniques for treating gynecomastia. We report a new surgical technique in an adolescent with fatty glandular gynecomastia grade III, who was referred from an endocrinologist to our clinic. We excised the gynecomastia with nipple repositioning utilizing the dermoglandular flap (about 1 cm thickness and 10 cm width). After one month, no complication was detected and the patient was satisfied with his new breasts. We suggest this technique for fatty glandular gynecomastia grade III. PMID:26284186

  6. Optimizing and Evaluating an Integrated SPECT-CmT System Dedicated to Improved 3-D Breast Cancer Imaging

    DTIC Science & Technology

    2009-05-01

    sagittal slices of a breast cancer patient (42yrs, 68kg) with implant and biopsy clip and various identified tissues . Glandular Adipose Implant...Biopsy Clip 13 volumetric imaging to effectively differentiate between normal glandular, adipose tissue and the artificial implants. It is...impacting the lowered head section. A. SPECT Sub-System The main component of the SPECT sub-system is a compact 16x20cm2 field of view Cadmium - Zinc

  7. Advances in Diagnostics and Treatments in Horses and Foals with Gastric and Duodenal Ulcers.

    PubMed

    Camacho-Luna, Pilar; Buchanan, Benjamin; Andrews, Frank M

    2018-04-01

    Equine gastric ulcer syndrome (EGUS) primarily describes ulceration in the terminal esophagus, nonglandular squamous mucosa, glandular mucosa of the stomach, and proximal duodenum. EGUS is common in all breeds and ages of horses and foals. This article focuses on the current terminology for EGUS, etiologies and pathogenesis for lesions in the nonglandular and glandular stomach, diagnosis, and a comprehensive approach to the treatment and prevention of EGUS in adult horses and foals. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Transitional cell carcinoma of the retrorectal space arisen in tailgut cyst: a case report and review of the literature.

    PubMed

    Vinciguerra, Gian Luca Rampioni; Mercantini, Paolo; La Torre, Marco; Pilozzi, Emanuela; Ziparo, Vincenzo; Vecchione, Andrea

    2014-05-01

    Tailgut cysts, also known as retrorectal cystic hamartomas, are congenital lesions derived by an abnormal remnant of the postanal primitive hindgut, consisting of unilocular or multilocular cysts usually lined by squamous, transitional, or glandular epithelium. Malignant transformation is an uncommon event, and it mainly involves the neuroendocrine or glandular epithelium; other histotypes are sporadic. Here, we report, for the first time, the clinicopathological features of a transitional cell carcinoma that arose in a tailgut cyst.

  9. Trichomes and chemical composition of the volatile oil of Trichogonia cinerea (Gardner) R. M. King & H. Rob. (Eupatorieae, Asteraceae).

    PubMed

    Fernandes, Yanne S; Trindade, Luma M P; Rezende, Maria Helena; Paula, José R; Gonçalves, Letícia A

    2016-03-01

    Trichogonia cinerea is endemic to Brazil and occurs in areas of cerrado and campo rupestre. In this study, we characterized the glandular and non-glandular trichomes on the aerial parts of this species, determined the principal events in the development of the former, and identified the main constituents of the volatile oil produced in its aerial organs. Fully expanded leaves, internodes, florets, involucral bracts, and stem apices were used for the characterization of trichomes. Leaves, internodes, florets, and involucral bracts were examined by light microscopy and scanning electron microscopy, whereas stem apices were examined only by light microscopy. Branches in the reproductive phase were used for the extraction and determination of the composition of the volatile oil. The species has three types of glandular trichomes, biseriate vesicular, biseriate pedunculate, and multicellular uniseriate, which secrete volatile oils and phenolic compounds. The major components identified in the volatile oil were 3,5-muuroladiene (39.56%) and butylated hydroxytoluene (13.07%).

  10. Function of the parotid gland in juvenile recurrent parotitis: a case series.

    PubMed

    Xie, Li-song; Pu, Yi-ping; Zheng, Ling-yan; Yu, Chuang-qi; Wang, Zhi-jun; Shi, Huan

    2016-04-01

    Our aim was to find out how the parotid gland functions in 44 patients with juvenile recurrent parotitis, and to assess the value of measuring the serum amylase activity. Clinical and personal details were recorded, and all patients had their serum amylase activity measured together with sialography during the chronic phase. The function of the gland was classified by sialographic images. The chi square test and Spearman's rank correlation coefficient were used in the statistical analyses. There was a significant association between the degree of glandular function and serum amylase activity (p=0.014). The patients with unilateral and bilateral disease differed significantly in their degree of glandular function (p=0.020), those with bilateral disease having poorer function. There were no significant correlations between other clinical variables and glandular function. Serum amylase activity is an important diagnostic variable in juvenile recurrent parotitis, and poor parotid function reflects the severity of the disease. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. Failure of dietary alpha-difluoromethylornithine to inhibit gastric carcinogenesis in rats after 8 weeks of treatment with N-methyl-N'-nitro-N-nitrosoguanidine and sodium chloride.

    PubMed

    Tanakamaru, Z; Nishikawa, A; Furukawa, F; Imazawa, T; Lee, I S; Kasahara, K; Tanaka, T; Takahashi, M

    1997-11-25

    The modifying effects of alpha-difluoromethylomithine (DFMO) on glandular stomach carcinogenesis after initiation with N-methyl-N'-nitro-N-nitrosoguanidine (MNNG) and sodium chloride were investigated in male outbred Wistar rats. Animals were simultaneously given MNNG solution (100 ppm) as their drinking water and diet supplemented with 10% sodium chloride for 8 weeks, and administered DFMO (dietary levels of 2000 ppm or 500 ppm) and tap water for the following 70 weeks. The DFMO treatment did not show any tendency to inhibit the development of gastric adenocarcinomas. The incidences and multiplicities of atypical hyperplasias in the glandular stomachs were also comparable in all groups of rats given MNNG/sodium chloride. Neither gastric carcinomas nor atypical hyperplasias were observed without the carcinogen treatment. Thus, DFMO did not exert any inhibitory effects when given during the post-initiation phase of two-stage glandular stomach carcinogenesis in rats initiated with MNNG and sodium chloride for 8 weeks.

  12. Gold and its relationship to neurological/glandular conditions.

    PubMed

    Richards, Douglas G; McMillin, David L; Mein, Eric A; Nelson, Carl D

    2002-01-01

    Despite increasing sales of gold supplements, and claims of benefits for neurological and glandular conditions, gold has received little attention in modern medical literature except as a drug for rheumatoid arthritis. Historically, however, gold had a reputation as a "nervine," a therapy for nervous disorders. A review of the historical literature shows gold in use during the 19th century for conditions including depression, epilepsy, migraine, and glandular problems such as amenorrhea and impotence. The most notable use of gold was in a treatment for alcoholism developed by Keeley (1897). In the modern medical literature, gold-containing medicines for rheumatoid arthritis are known to have occasional neurotoxic adverse effects. There are also a few studies suggesting a role for gold as a naturally occurring trace element in the reproductive glands. One small recent study demonstrated a possible positive effect of gold on cognitive ability. There is a need for more experimental and clinical research of the neuropharmacology and neurochemistry of gold, and for the exploration of gold's possible role as a trace element.

  13. Mirid (Hemiptera: Heteroptera) specialists of sticky plants: adaptations, interactions, and ecological implications.

    PubMed

    Wheeler, Alfred G; Krimmel, Billy A

    2015-01-07

    Sticky plants-those having glandular trichomes (hairs) that produce adhesive, viscous exudates-can impede the movement of, and entrap, generalist insects. Disparate arthropod groups have adapted to these widespread and taxonomically diverse plants, yet their interactions with glandular hosts rarely are incorporated into broad ecological theory. Ecologists and entomologists might be unaware of even well-documented examples of insects that are sticky-plant specialists. The hemipteran family Miridae (more specifically, the omnivorous Dicyphini: Dicyphina) is the best-known group of arthropods that specializes on sticky plants. In the first synthesis of relationships with glandular plants for any insect family, we review mirid interactions with sticky hosts, including their adaptations (behavioral, morphological, and physiological) and mutualisms with carnivorous plants, and the ecological and agricultural implications of mirid-sticky plant systems. We propose that mirid research applies generally to tritrophic interactions on trichome-defended plants, enhances an understanding of insect-plant interactions, and provides information useful in managing crop pests.

  14. Changes in ultrasound shear wave elastography properties of normal breast during menstrual cycle.

    PubMed

    Rzymski, P; Skórzewska, A; Opala, T

    2011-01-01

    Elastography is a novel technique capable of noninvasively assessing the elastic properties of breast tissue. Because the risk factors for breast cancer include hormonal status and proliferation, the aim of our study was to estimate the intensity of sonoelastographic changes during the menstrual cycle. Eight women aged 20-23 years with regular menstrual cycles underwent B-mode sonography and sonoelastography (ShearWave on Aixplorer, France) on days 3, 10, 17 and 24. Mean values of glandular and fat tissue elasticity did not change statistically significantly during the menstrual cycle as well as glandular to fat tissue ratio. During almost the whole cycle differences between outer and inner quadrants in glandular and fat tissue were statistically significant. The lowest values of elasticity occurred on the 10th day and the highest on the 24th of the menstrual cycle. There were statistically significant differences in elasticity between inner and outer quadrants of both breasts close to day 3 and 17 of the menstrual cycle.

  15. Protected by fumigants: beetle perfumes in antimicrobial defense.

    PubMed

    Gross, Jürgen; Schumacher, Kerstin; Schmidtberg, Henrike; Vilcinskas, Andreas

    2008-02-01

    Beetles share with other eukaryotes an innate immune system that mediates endogenous defense against pathogens. In addition, larvae of some taxa produce fluid exocrine secretions that contain antimicrobial compounds. In this paper, we provide evidence that larvae of the brassy willow leaf beetle Phratora vitellinae constitutively release volatile glandular secretions that combat pathogens in their microenvironment. We identified salicylaldehyde as the major component of their enveloping perfume cloud, which is emitted by furrow-shaped openings of larval glandular reservoirs and which inhibits in vitro the growth of the bacterial entomopathogen Bacillus thuringiensis. The suggested role of salicylaldehyde as a fumigant in exogenous antimicrobial defense was confirmed in vivo by its removal from glandular reservoirs. This resulted in an enhanced susceptibility of the larvae to infection with the fungal entomopathogens Beauveria bassiana and Metarhizium anisopliae. Consequently, we established the hypothesis that antimicrobial defense in beetles can be expanded beyond innate immunity to include external disinfection of their microenvironment, and we report for the first time the contribution of fumigants to antimicrobial defense in animals.

  16. The Model Averaging for Dichotomous Response Benchmark Dose (MADr-BMD) Tool

    EPA Pesticide Factsheets

    Providing quantal response models, which are also used in the U.S. EPA benchmark dose software suite, and generates a model-averaged dose response model to generate benchmark dose and benchmark dose lower bound estimates.

  17. Barrett's oesophagus: intestinal metaplasia is not essential for cancer risk.

    PubMed

    Kelty, Clive J; Gough, Martin D; Van Wyk, Quintin; Stephenson, Timothy J; Ackroyd, Roger

    2007-11-01

    Barrett's oesophagus is the main identifiable risk factor for oesophageal adenocarcinoma. It has been suggested that only patients with intestinal metaplasia are at risk of cancer, but the British Society of Gastroenterology (BSG) guidelines suggest that glandular mucosa is all that is needed. The aim of this study was to quantify the risk of adenocarcinoma in columnar-lined lower oesophagus, with or without specialized intestinal metaplasia. All patients who had endoscopic biopsies of the lower oesophagus between 1980 and 1994 in a single-centre teaching hospital were included in the study. All histological specimens were re-examined and reported according to whether they contained columnar epithelial-lined lower oesophagus, glandular mucosa, with or without intestinal metaplasia. The primary outcome measure was the development of adenocarcinoma. In total, 712 patients were identified. Of these, 379 (55.1%) were found to have specialized intestinal metaplasia (SIM), and the remaining 309 (44.9%, p = NS) were reported as having glandular mucosa (GM). The median follow-up for patients was 12 years (range 8-20 years). Twenty-eight patients went on to develop adenocarcinoma (4.1%) during the follow-up period - 17 in the SIM group (4.5%) and 11 in the GM group (3.6%, p =NS). The oesophageal malignancy rate was 0.34% per year (SIM 0.37%, GM 0.30%; p =NS). Patients who have glandular mucosa on biopsy without intestinal metaplasia have a similar cancer risk to those with specialized intestinal metaplasia.

  18. Ultrastructure of posterior sternal glands of Macrotermes annandalei (Silvestri): new members of the sexual glandular set found in termites (Insecta).

    PubMed

    Quennedey, André; Peppuy, Alexis; Courrent, Annie; Robert, Alain; Everaerts, Claude; Bordereau, Christian

    2004-12-01

    In female alates of Macrotermes annandalei, two types of abdominal glands are involved in the secretion of sex pheromone. Tergal glands are found at the anterior margin of tergites 6-10 and posterior sternal glands (PSGs) are located at the anterior margin of sternites 6-7. The cytological features of both types of glands are quite similar. The fine structural organization of PSGs is studied more precisely and described for the first time. The glandular cuticle is pitted with narrow apertures corresponding to the openings of numerous subcuticular pouches. Several Class 3 glandular units open in each pouch. One canal cell and one secretory cell make an individual glandular unit. The canal cell is enlarged apically and is connected with the other canal cells to form a common pouch. Based on the structural features found in these glands, we propose a common secretory process for PSGs and tergal glands. During the physiological maturation of alates inside the nest, secretory vesicles amass in the cytoplasm of secretory cells, while large intercellular spaces collapse the cuticular pouches. At the time of dispersal flight, pouches are filled with the content of secretory vesicles while intercellular spaces are sharply reduced. After calling behavior, no secretion remains in the glands and pouches collapse again, while secretory cells are drastically reduced in size. The structure and the secretory processes of PSGs and tergal glands are compared to those of abdominal sexual glands known in termites.

  19. Artemisia annua mutant impaired in artemisinin synthesis demonstrates importance of nonenzymatic conversion in terpenoid metabolism.

    PubMed

    Czechowski, Tomasz; Larson, Tony R; Catania, Theresa M; Harvey, David; Brown, Geoffrey D; Graham, Ian A

    2016-12-27

    Artemisinin, a sesquiterpene lactone produced by Artemisia annua glandular secretory trichomes, is the active ingredient in the most effective treatment for malaria currently available. We identified a mutation that disrupts the amorpha-4,11-diene C-12 oxidase (CYP71AV1) enzyme, responsible for a series of oxidation reactions in the artemisinin biosynthetic pathway. Detailed metabolic studies of cyp71av1-1 revealed that the consequence of blocking the artemisinin biosynthetic pathway is the redirection of sesquiterpene metabolism to a sesquiterpene epoxide, which we designate arteannuin X. This sesquiterpene approaches half the concentration observed for artemisinin in wild-type plants, demonstrating high-flux plasticity in A. annua glandular trichomes and their potential as factories for the production of novel alternate sesquiterpenes at commercially viable levels. Detailed metabolite profiling of leaf maturation time-series and precursor-feeding experiments revealed that nonenzymatic conversion steps are central to both artemisinin and arteannuin X biosynthesis. In particular, feeding studies using 13 C-labeled dihydroartemisinic acid (DHAA) provided strong evidence that the final steps in the synthesis of artemisinin are nonenzymatic in vivo. Our findings also suggest that the specialized subapical cavity of glandular secretory trichomes functions as a location for both the chemical conversion and the storage of phytotoxic compounds, including artemisinin. We conclude that metabolic engineering to produce high yields of novel secondary compounds such as sesquiterpenes is feasible in complex glandular trichomes. Such systems offer advantages over single-cell microbial hosts for production of toxic natural products.

  20. Systemic and mammary gland disposition of enrofloxacin in healthy sheep following intramammary administration.

    PubMed

    López, Cristina; García, Juan José; Sierra, Matilde; Diez, María José; Pérez, Claudia; Sahagún, Ana Maria; Fernández, Nélida

    2015-04-09

    Mastitis is one of the most important diseases affecting dairy sheep. Antimicrobial drugs are often administered directly through teat to treat or prevent this disease, but data on drug distribution within glandular tissue are scarce and it cannot be estimated from concentrations in milk. Thus, the aim of this study was to investigate systemic and mammary gland distribution of enrofloxacin after intramammary administration. The drug was administered to 6 healthy lactating Assaf sheep with an injector containing an enrofloxacin preparation (1 g drug/5 g ointment). Blood samples were collected at 0, 30, 60, 90, 120, 150 and 180 min. Animals were then sedated and sacrificed, and glandular tissue samples were obtained from treated udders at 2, 4, 6 and 8 cm height. Enrofloxacin concentrations were measured in plasma and tissue samples by UV high-performed liquid chromatography. Mean enrofloxacin plasma concentrations were below 0.5 μg/mL. Mean tissue concentrations decreased in mammary gland with vertical distance from the teat, ranging from 356.6 μg/g at 2 cm to 95.60 μg/g at the base of the udder. Glandular tissue concentrations best fitted to a decreasing monoexponential model, and showed a good correlation with an ex vivo model previously developed. Enrofloxacin concentrations were effective in the entire glandular tissue against the main pathogens causing mastitis in sheep. These results suggest that this drug may be suitable to treat mastitis in sheep by intramammary administration.

  1. Alkaline comet assay in liver and stomach, and micronucleus assay in bone marrow, from rats treated with 2-acetylaminofluorene, azidothymidine, cisplatin, or isobutyraldehyde.

    PubMed

    Kraynak, A R; Barnum, J E; Cunningham, C L; Ng, A; Ykoruk, B A; Bennet, B; Stoffregen, D; Merschman, M; Freeland, E; Galloway, S M

    2015-07-01

    As part of the Japanese Center for the Validation of Alternative Methods (JaCVAM) initiative international validation study of the in vivo rat alkaline comet assay (comet assay), we examined the ability of the assay to determine the genotoxicity of 2-acetylaminofluorene (AAF), azidothymidine (AZT), cisplatin (CPN), and isobutyraldehyde (IBA) in liver and glandular stomach of male Sprague-Dawley rats. Rats were given oral doses of test compound or control once daily for three days. High dose levels were approximately maximum tolerated doses and were based on preliminary range-finding studies. Tissues were harvested 3h after the final dose (48h after the initial dose). A bone marrow micronucleus assay (MN) was also conducted on the rats treated with AZT, CPN, and IBA. Acute toxic effects of treatment were determined primarily through histomorphologic analysis of liver and stomach but also by body weight and serum liver enzyme changes. The comet assay was conducted on fresh tissue preparations but frozen samples from two studies were also assayed. Statistically significant dose-related differences in comet % DNA in tail were found in liver and stomach for the genotoxin AZT and in liver for the genotoxin CPN, but not in liver or stomach for the non-genotoxin IBA. Statistically significant differences in % DNA in tail were measured in liver for the low and mid dose of the genotoxin AAF, but not the high dose. The comet assays of frozen liver suspensions from CPN- and AAF-treated rats yielded comparable results to the assays of fresh preparations. There were no indications of significant toxicity induced by any treatment. The micronucleus assay was positive for CPN and AZT and negative for IBA. In conclusion, the in vivo comet assay is capable of detecting genotoxic effects of a variety of chemicals and may fill an important role in the genotoxicity test battery. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Frame average optimization of cine-mode EPID images used for routine clinical in vivo patient dose verification of VMAT deliveries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCowan, P. M., E-mail: pmccowan@cancercare.mb.ca; McCurdy, B. M. C.; Medical Physics Department, CancerCare Manitoba, 675 McDermot Avenue, Winnipeg, Manitoba R3E 0V9

    Purpose: The in vivo 3D dose delivered to a patient during volumetric modulated arc therapy (VMAT) delivery can be calculated using electronic portal imaging device (EPID) images. These images must be acquired in cine-mode (i.e., “movie” mode) in order to capture the time-dependent delivery information. The angle subtended by each cine-mode EPID image during an arc can be changed via the frame averaging number selected within the image acquisition software. A large frame average number will decrease the EPID’s angular resolution and will result in a decrease in the accuracy of the dose information contained within each image. Alternatively, lessmore » EPID images acquired per delivery will decrease the overall 3D patient dose calculation time, which is appealing for large-scale clinical implementation. Therefore, the purpose of this study was to determine the optimal frame average value per EPID image, defined as the highest frame averaging that can be used without an appreciable loss in 3D dose reconstruction accuracy for VMAT treatments. Methods: Six different VMAT plans and six different SBRT-VMAT plans were delivered to an anthropomorphic phantom. Delivery was carried out on a Varian 2300ix model linear accelerator (Linac) equipped with an aS1000 EPID running at a frame acquisition rate of 7.5 Hz. An additional PC was set up at the Linac console area, equipped with specialized frame-grabber hardware and software packages allowing continuous acquisition of all EPID frames during delivery. Frames were averaged into “frame-averaged” EPID images using MATLAB. Each frame-averaged data set was used to calculate the in vivo dose to the patient and then compared to the single EPID frame in vivo dose calculation (the single frame calculation represents the highest possible angular resolution per EPID image). A mean percentage dose difference of low dose (<20% prescription dose) and high dose regions (>80% prescription dose) was calculated for each frame averaged scenario for each plan. The authors defined their unacceptable loss of accuracy as no more than a ±1% mean dose difference in the high dose region. Optimal frame average numbers were then determined as a function of the Linac’s average gantry speed and the dose per fraction. Results: The authors found that 9 and 11 frame averages were suitable for all VMAT and SBRT-VMAT treatments, respectively. This resulted in no more than a 1% loss to any of the dose region’s mean percentage difference when compared to the single frame reconstruction. The optimized number was dependent on the treatment’s dose per fraction and was determined to be as high as 14 for 12 Gy/fraction (fx), 15 for 8 Gy/fx, 11 for 6 Gy/fx, and 9 for 2 Gy/fx. Conclusions: The authors have determined an optimal EPID frame averaging number for multiple VMAT-type treatments. These are given as a function of the dose per fraction and average gantry speed. These optimized values are now used in the authors’ clinical, 3D, in vivo patient dosimetry program. This provides a reduction in calculation time while maintaining the authors’ required level of accuracy in the dose reconstruction.« less

  3. Dosimetry in x-ray-based breast imaging

    PubMed Central

    Dance, David R; Sechopoulos, Ioannis

    2016-01-01

    The estimation of the mean glandular dose to the breast (MGD) for x-ray based imaging modalities forms an essential part of quality control and is needed for risk estimation and for system design and optimisation. This review considers the development of methods for estimating the MGD for mammography, digital breast tomosynthesis (DBT) and dedicated breast CT (DBCT). Almost all of the methodology used employs Monte Carlo calculated conversion factors to relate the measurable quantity, generally the incident air kerma, to the MGD. After a review of the size and composition of the female breast, the various mathematical models used are discussed, with particular emphasis on models for mammography. These range from simple geometrical shapes, to the more recent complex models based on patient DBCT examinations. The possibility of patient-specific dose estimates is considered as well as special diagnostic views and the effect of breast implants. Calculations using the complex models show that the MGD for mammography is overestimated by about 30% when the simple models are used. The design and uses of breast-simulating test phantoms for measuring incident air kerma are outlined and comparisons made between patient and phantom-based dose estimates. The most widely used national and international dosimetry protocols for mammography are based on different simple geometrical models of the breast, and harmonisation of these protocols using more complex breast models is desirable. PMID:27617767

  4. Dosimetry in x-ray-based breast imaging

    NASA Astrophysics Data System (ADS)

    Dance, David R.; Sechopoulos, Ioannis

    2016-10-01

    The estimation of the mean glandular dose to the breast (MGD) for x-ray based imaging modalities forms an essential part of quality control and is needed for risk estimation and for system design and optimisation. This review considers the development of methods for estimating the MGD for mammography, digital breast tomosynthesis (DBT) and dedicated breast CT (DBCT). Almost all of the methodology used employs Monte Carlo calculated conversion factors to relate the measurable quantity, generally the incident air kerma, to the MGD. After a review of the size and composition of the female breast, the various mathematical models used are discussed, with particular emphasis on models for mammography. These range from simple geometrical shapes, to the more recent complex models based on patient DBCT examinations. The possibility of patient-specific dose estimates is considered as well as special diagnostic views and the effect of breast implants. Calculations using the complex models show that the MGD for mammography is overestimated by about 30% when the simple models are used. The design and uses of breast-simulating test phantoms for measuring incident air kerma are outlined and comparisons made between patient and phantom-based dose estimates. The most widely used national and international dosimetry protocols for mammography are based on different simple geometrical models of the breast, and harmonisation of these protocols using more complex breast models is desirable.

  5. Luteal start vaginal micronized progesterone improves pregnancy success in women with recurrent pregnancy loss.

    PubMed

    Stephenson, Mary D; McQueen, Dana; Winter, Michelle; Kliman, Harvey J

    2017-03-01

    To assess the effectiveness of luteal start vaginal micronized P in a recurrent pregnancy loss (RPL) cohort. Observational cohort study using prospectively collected data. Not applicable. Women seen between 2004 and 2012 with a history of two or more unexplained pregnancy losses <10 weeks in size; endometrial biopsy (EB) performed 9-11 days after LH surge; and one or more subsequent pregnancy(ies). Women were excluded if concomitant findings, such as endometritis, maturation delay, or glandular-stromal dyssynchrony, were identified on EB. Vaginal micronized P was prescribed at a dose of 100-200 mg every 12 hours starting 3 days after LH surge (luteal start) if glandular epithelial nuclear cyclin E (nCyclinE) expression was elevated (>20%) in endometrial glands or empirically despite normal nCyclinE (≤20%). Women with normal nCyclinE (≤20%) who did not receive P were used as controls. Pregnancy success was an ongoing pregnancy >10 weeks in size. One hundred sixteen women met the inclusion criteria, of whom 51% (n = 59) had elevated nCyclinE and 49% (n = 57) had normal nCyclinE. Pregnancy success in the 59 women with elevated nCyclinE significantly improved after intervention: 6% (16/255) in prior pregnancies versus 69% (57/83) in subsequent pregnancies. Pregnancy success in subsequent pregnancies was higher in women prescribed vaginal micronized P compared with controls: 68% (86/126) versus 51% (19/37); odds ratio = 2.1 (95% confidence interval, 1.0-4.4). In this study, we found that the use of luteal start vaginal micronized P was associated with improved pregnancy success in a strictly defined cohort of women with RPL. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  6. Differences in botulinum toxin dosing between patients with adductor spasmodic dysphonia and essential voice tremor.

    PubMed

    Orbelo, Diana M; Duffy, Joseph R; Hughes Borst, Becky J; Ekbom, Dale; Maragos, Nicolas E

    2014-01-01

    To explore possible dose differences in average botulinum toxin (BTX) given to patients with adductor spasmodic dysphonia (ADSD) compared with patients with essential voice tremor (EVT). A retrospective study compared the average BTX dose injected in equal doses to the thyroarytenoid (TA) muscles of 51 patients with ADSD with 52 patients with EVT. Those with ADSD received significantly higher total doses (6.80 ± 2.79 units) compared with those with EVT (5.02 ± 1.65 units). Dose at time of first injection, age at time of first injection, gender, year of first injection, and average time between injections were included in multivariate analysis but did not interact with total average dose findings. Patients with ADSD may need relatively higher doses of BTX injections to bilateral TA muscles compared with patients with EVT. Copyright © 2014 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  7. Exposure of the Heart in Breast Cancer Radiation Therapy: A Systematic Review of Heart Doses Published During 2003 to 2013.

    PubMed

    Taylor, Carolyn W; Wang, Zhe; Macaulay, Elizabeth; Jagsi, Reshma; Duane, Frances; Darby, Sarah C

    2015-11-15

    Breast cancer radiation therapy cures many women, but where the heart is exposed, it can cause heart disease. We report a systematic review of heart doses from breast cancer radiation therapy that were published during 2003 to 2013. Eligible studies were those reporting whole-heart dose (ie, dose averaged over the whole heart). Analyses considered the arithmetic mean of the whole-heart doses for the CT plans for each regimen in each study. We termed this "mean heart dose." In left-sided breast cancer, mean heart dose averaged over all 398 regimens reported in 149 studies from 28 countries was 5.4 Gy (range, <0.1-28.6 Gy). In regimens that did not include the internal mammary chain (IMC), average mean heart dose was 4.2 Gy and varied with the target tissues irradiated. The lowest average mean heart doses were from tangential radiation therapy with either breathing control (1.3 Gy; range, 0.4-2.5 Gy) or treatment in the lateral decubitus position (1.2 Gy; range, 0.8-1.7 Gy), or from proton radiation therapy (0.5 Gy; range, 0.1-0.8 Gy). For intensity modulated radiation therapy mean heart dose was 5.6 Gy (range, <0.1-23.0 Gy). Where the IMC was irradiated, average mean heart dose was around 8 Gy and varied little according to which other targets were irradiated. Proton radiation therapy delivered the lowest average mean heart dose (2.6 Gy, range, 1.0-6.0 Gy), and tangential radiation therapy with a separate IMC field the highest (9.2 Gy, range, 1.9-21.0 Gy). In right-sided breast cancer, the average mean heart dose was 3.3 Gy based on 45 regimens in 23 studies. Recent estimates of typical heart doses from left breast cancer radiation therapy vary widely between studies, even for apparently similar regimens. Maneuvers to reduce heart dose in left tangential radiation therapy were successful. Proton radiation therapy delivered the lowest doses. Inclusion of the IMC doubled typical heart dose. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. SU-F-P-27: The Study of Actual DVH for Target and OARs During the Radiotherapy of Non-Small Cell Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, C; Yin, Y

    2016-06-15

    Purpose: To analyze the changes of the volume and dosimetry of target and organs at risk (OARs) by comparing the daily CBCT images and planning CT images of the patients with Non-Small Cell Lung Cancer (NSCLC) and analyze the difference between planned dose and accumulated dose. Methods: This study retrospectively analyzed eight cases of non-small cell lung cancer patients who accepted CRT or IMRT treatment and KV-CBCT. For each patient, the prescription dose was 60Gy and the fraction dose was 2Gy. Deform the daily CBCT images to planning CT images by the mapping of registration to compare the planning dosemore » with cumulative dose of targets and organs at risk in RayStation. Results: The average volume of GTV of 8 patients with CBCT was 88.26% of the original volume. The average plan dose of GTV was 64.49±2.40Gy. The accumulated dose of GTV was 60.13±2.70Gy (P≤0.05). The average volume of PTV to reach the prescription dose was 95.59% for original plan and 81.47% for accumulated plan (P≤0.05). The volume changes of the left and right lung of the original volume was 88.95% and 80.32%, respectively. The average dose of the left and right lung of original plan was 9.31±1.75Gy and 4.33±1.10Gy, respectively(P≥0.05). The average accumulated dose was 9.63±1.96Gy and 4.63±1.36Gy, respectively(P≥0.05). The average plan dose and accumulated dose of heart was 6.88±1.70Gy and 6.38±0.91Gy, respectively (P≥0.05). The average plan maximum dose and accumulated dose for spinal cord was 24.62±5.91Gy and 26.00±5.14Gy, respectively (P≥0.05). Conclusion: The changes of target anatomical structure with NSCLC make difference between the planned dose and cumulative dose. With the dose deformation method, the dose gap can be found between planning dose and delivery dose.« less

  9. Effect of 935-MHz phone-simulating electromagnetic radiation on endometrial glandular cells during mouse embryo implantation.

    PubMed

    Liu, Wenhui; Zheng, Xinmin; Qu, Zaiqing; Zhang, Ming; Zhou, Chun; Ma, Ling; Zhang, Yuanzhen

    2012-10-01

    This study examined the impact of 935MHz phone-simulating electromagnetic radiation on embryo implantation of pregnant mice. Each 7-week-old Kunming (KM) female white mouse was set up with a KM male mouse in a single cage for mating overnight after induction of ovulation. In the first three days of pregnancy, the pregnant mice was exposed to electromagnetic radiation at low-intensity (150 μW/cm(2), ranging from 130 to 200 μW/cm(2), for 2- or 4-h exposure every day), mid-intensity (570 μW/cm(2), ranging from 400 to 700 μW/cm(2), for 2- or 4-h exposure every day) or high-intensity (1400 μW/cm(2), ranging from 1200 to 1500 μW/cm(2), for 2- or 4-h exposure every day), respectively. On the day 4 after gestation (known as the window of murine embryo implantation), the endometrium was collected and the suspension of endometrial glandular cells was made. Laser scanning microscopy was employed to detect the mitochondrial membrane potential and intracellular calcium ion concentration. In high-intensity, 2- and 4-h groups, mitochondrial membrane potential of endometrial glandular cells was significantly lower than that in the normal control group (P<0.05). The calcium ion concentration was increased in low-intensity 2-h group but decreased in high-intensity 4-h group as compared with the normal control group (P<0.05). However, no significant difference was found in mitochondrial membrane potential of endometrial glandular cells between low- or mid-intensity groups and the normal control group, indicating stronger intensity of the electromagnetic radiation and longer length of the radiation are required to inflict a remarkable functional and structural damage to mitochondrial membrane. Our data demonstrated that electromagnetic radiation with a 935-MHz phone for 4 h conspicuously decreased mitochondrial membrane potential and lowered the calcium ion concentration of endometrial glandular cells. It is suggested that high-intensity electromagnetic radiation is very likely to induce the death of embryonic cells and decrease the chance of their implantation, thereby posing a high risk to pregnancy.

  10. Antibodies against Escherichia coli O24 and O56 O-Specific Polysaccharides Recognize Epitopes in Human Glandular Epithelium and Nervous Tissue

    PubMed Central

    Korzeniowska-Kowal, Agnieszka; Kochman, Agata; Gamian, Elżbieta; Lis-Nawara, Anna; Lipiński, Tomasz; Seweryn, Ewa; Ziółkowski, Piotr; Gamian, Andrzej

    2015-01-01

    Lipopolysaccharide (LPS), the major component of the outer membrane of Gram-negative bacteria, contains the O-polysaccharide, which is important to classify bacteria into different O-serological types within species. The O-polysaccharides of serotypes O24 and O56 of E. coli contain sialic acid in their structures, already established in our previous studies. Here, we report the isolation of specific antibodies with affinity chromatography using immobilized lipopolysaccharides. Next, we evaluated the reactivity of anti-O24 and anti-O56 antibody on human tissues histologically. The study was conducted under the assumption that the sialic acid based molecular identity of bacterial and tissue structures provides not only an understanding of the mimicry-based bacterial pathogenicity. Cross-reacting antibodies could be used to recognize specific human tissues depending on their histogenesis and differentiation, which might be useful for diagnostic purposes. The results indicate that various human tissues are recognized by anti-O24 and anti-O56 antibodies. Interestingly, only a single specific reactivity could be found in the anti-O56 antibody preparation. Several tissues studied were not reactive with either antibody, thus proving that the presence of cross-reactive antigens was tissue specific. In general, O56 antibody performed better than O24 in staining epithelial and nervous tissues. Positive staining was observed for both normal (ganglia) and tumor tissue (ganglioneuroma). Epithelial tissue showed positive staining, but an epitope recognized by O56 antibody should be considered as a marker of glandular epithelium. The reason is that malignant glandular tumor and its metastasis are stained, and also epithelium of renal tubules and glandular structures of the thyroid gland are stained. Stratified epithelium such as that of skin is definitely not stained. Therefore, the most relevant observation is that the epitope recognized by anti-O56 antibodies is a new marker specific for glandular epithelium and nervous tissue. Further studies should be performed to determine the structure of the tissue epitope recognized. PMID:26086646

  11. MO-FG-CAMPUS-IeP1-02: Dose Reduction in Contrast-Enhanced Digital Mammography Using a Photon-Counting Detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, S; Kang, S; Eom, J

    Purpose: Photon-counting detectors (PCDs) allow multi-energy X-ray imaging without additional exposures and spectral overlap. This capability results in the improvement of accuracy of material decomposition for dual-energy X-ray imaging and the reduction of radiation dose. In this study, the PCD-based contrast-enhanced dual-energy mammography (CEDM) was compared with the conventional CDEM in terms of radiation dose, image quality and accuracy of material decomposition. Methods: A dual-energy model was designed by using Beer-Lambert’s law and rational inverse fitting function for decomposing materials from a polychromatic X-ray source. A cadmium zinc telluride (CZT)-based PCD, which has five energy thresholds, and iodine solutions includedmore » in a 3D half-cylindrical phantom, which composed of 50% glandular and 50% adipose tissues, were simulated by using a Monte Carlo simulation tool. The low- and high-energy images were obtained in accordance with the clinical exposure conditions for the conventional CDEM. Energy bins of 20–33 and 34–50 keV were defined from X-ray energy spectra simulated at 50 kVp with different dose levels for implementing the PCD-based CDEM. The dual-energy mammographic techniques were compared by means of absorbed dose, noise property and normalized root-mean-square error (NRMSE). Results: Comparing to the conventional CEDM, the iodine solutions were clearly decomposed for the PCD-based CEDM. Although the radiation dose for the PCD-based CDEM was lower than that for the conventional CEDM, the PCD-based CDEM improved the noise property and accuracy of decomposition images. Conclusion: This study demonstrates that the PCD-based CDEM allows the quantitative material decomposition, and reduces radiation dose in comparison with the conventional CDEM. Therefore, the PCD-based CDEM is able to provide useful information for detecting breast tumor and enhancing diagnostic accuracy in mammography.« less

  12. Skin Dosimetry in Breast Teletherapy on a Phantom Anthropomorphic and Anthropometric Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Batista Nogueira, Luciana; Lemos Silva, Hugo Leonardo; Donato da Silva, Sabrina

    This paper addresses the breast teletherapy dosimetry. The goal is to evaluate and compare absorbed doses in equivalent skin tissue, TE-skin, of an anthropomorphic and anthropometric breast phantom submitted to breast radiotherapy. The methodology involved the reproduction of a set of tomographic images of the phantom; the elaboration of conformational radiotherapy planning in the SOMAVISION and CadPlan (TPS) software; and the synthetic breast irradiation by parallel opposed fields in 3D conformal teletherapy at 6 MV linear accelerator Clinac-2100 C from VARIAN with prescribed dose (PD) of 180 cGy to the target volume (PTV), referent to the glandular tissue. Radiochromic filmsmore » EBT2 were selected as dosimeters. Two independent calibration processes of films with solid water Gammex 457 plates and water filled box were produced. Curves of optical density (OD) versus absorbed dose were produced. Dosimeters were positioned in the external region of the breast phantom in contact with TE-skin, area of 4.0 cm{sup 2} each. The irradiation process was prepared in duplicate to check the reproducibility of the technique. The radiochromic films were scanned and their response in RGB (Red, Green, Blue) analyzed by the ImageJ software. The optical density was obtained and converted to dose based on the calibration curves. Thus, the spatial dose distribution in the skin was reproduced. The absorbed doses measured on the radiochromic films in TE-skin showed values between upper and lower quadrants at 9 o'clock in the range of 54% of PD, between the upper and lower quadrants 3 o'clock in the range of 72% and 6 o'clock at the lower quadrant in the range of 68 % of PD. The values are ±64% (p <0.05) according to the TPS. It is concluded that the depth dose measured in solid water plates or water box reproduce equivalent dose values for both calibration processes of the radiochromic films. It was observed that the skin received doses ranging from 50% to 78% of the prescribed dose after two parallel opposed irradiation fields. (authors)« less

  13. Artemisia annua mutant impaired in artemisinin synthesis demonstrates importance of nonenzymatic conversion in terpenoid metabolism

    PubMed Central

    Czechowski, Tomasz; Larson, Tony R.; Catania, Theresa M.; Harvey, David; Brown, Geoffrey D.; Graham, Ian A.

    2016-01-01

    Artemisinin, a sesquiterpene lactone produced by Artemisia annua glandular secretory trichomes, is the active ingredient in the most effective treatment for malaria currently available. We identified a mutation that disrupts the amorpha-4,11-diene C-12 oxidase (CYP71AV1) enzyme, responsible for a series of oxidation reactions in the artemisinin biosynthetic pathway. Detailed metabolic studies of cyp71av1-1 revealed that the consequence of blocking the artemisinin biosynthetic pathway is the redirection of sesquiterpene metabolism to a sesquiterpene epoxide, which we designate arteannuin X. This sesquiterpene approaches half the concentration observed for artemisinin in wild-type plants, demonstrating high-flux plasticity in A. annua glandular trichomes and their potential as factories for the production of novel alternate sesquiterpenes at commercially viable levels. Detailed metabolite profiling of leaf maturation time-series and precursor-feeding experiments revealed that nonenzymatic conversion steps are central to both artemisinin and arteannuin X biosynthesis. In particular, feeding studies using 13C-labeled dihydroartemisinic acid (DHAA) provided strong evidence that the final steps in the synthesis of artemisinin are nonenzymatic in vivo. Our findings also suggest that the specialized subapical cavity of glandular secretory trichomes functions as a location for both the chemical conversion and the storage of phytotoxic compounds, including artemisinin. We conclude that metabolic engineering to produce high yields of novel secondary compounds such as sesquiterpenes is feasible in complex glandular trichomes. Such systems offer advantages over single-cell microbial hosts for production of toxic natural products. PMID:27930305

  14. Polymethylated Myricetin in Trichomes of the Wild Tomato Species Solanum habrochaites and Characterization of Trichome-Specific 3′/5′- and 7/4′-Myricetin O-Methyltransferases1[C][W][OA

    PubMed Central

    Schmidt, Adam; Li, Chao; Shi, Feng; Jones, A. Daniel; Pichersky, Eran

    2011-01-01

    Flavonoids are a class of metabolites found in many plant species. They have been reported to serve several physiological roles, such as in defense against herbivores and pathogens and in protection against harmful ultraviolet radiation. They also serve as precursors of pigment compounds found in flowers, leaves, and seeds. Highly methylated, nonglycosylated derivatives of the flavonoid myricetin flavonoid, have been previously reported from a variety of plants, but O-methyltransferases responsible for their synthesis have not yet been identified. Here, we show that secreting glandular trichomes (designated types 1 and 4) and storage glandular trichomes (type 6) on the leaf surface of wild tomato (Solanum habrochaites accession LA1777) plants contain 3,7,3′-trimethyl myricetin, 3,7,3′,5′-tetramethyl myricetin, and 3,7,3′,4′,5′-pentamethyl myricetin, with gland types 1 and 4 containing severalfold more of these compounds than type 6 glands and with the tetramethylated compound predominating in all three gland types. We have also identified transcripts of two genes expressed in the glandular trichomes and showed that they encode enzymes capable of methylating myricetin at the 3′ and 5′ and the 7 and 4′ positions, respectively. Both genes are preferentially expressed in secreting glandular trichome types 1 and 4 and to a lesser degree in storage trichome type 6, and the levels of the proteins they encode are correspondingly higher in types 1 and 4 glands compared with type 6 glands. PMID:21343428

  15. Ultrastructure and elemental analysis of Hypoxis hemerocallidea: a multipurpose medicinal plant.

    PubMed

    Afolayan, Anthony J; Otunola, Gloria A

    2014-01-01

    Herbal medicine is a popular means of medical management in some parts of the world especially in Africa. Hypoxis hemerocallidea Fisch.C.A.Mey. & Avé-Lall, also known as African potato of the Hypoxidaecae family, is one of the medicinal plants that have enjoyed long usage as an herbal medicine in South Africa. In this study, the morphology and elemental constituents of H. hemerocallidea leaf was investigated to correlate the functional role of the ultrastructure in the production of therapeutic compounds. Fresh leaves of H. hemerocallidea were prepared for analysis using standard methods. The ultrastructure and crystal deposits of the plant were assessed using scanning electron microscopy (SEM), and energy dispersive x-ray (EDX). It was observed that the leaves were characterised by multicelullar glandular and non glandular trichomes which are sparsely distributed over the entire surfaces. The glandular trichomes (GTs) in H. hemerocallidea leaf have boulbous heads which are probably filled with secretions, while the non glandular trichomes were long, fibrous and sparse. EDX-SEM of Hypoxis hemerocallidea leaf revealed that carbon, oxygen, nitrogen and silicon are the major components of the deposits, while other elements such as iron, sulphur, sodium, calcium, magnesium, potassium, manganese, iodine, chromium and iodine were present in small but variable amounts. The presence of these elements which are crucial to maintaining good health, in addition to other bioactive constituents might be accountable for the multipurpose therapeutic uses of Hypoxis hemerocallidea in the treatment of cancers, HIV/AIDS related diseases, urinary tract infections, cardiovascular disorders, diabetes and other chronic ailments of humans.

  16. Extracellular matrix metalloproteinase inducer expression in the baboon endometrium: menstrual cycle and endometriosis

    PubMed Central

    Braundmeier, A G; Fazleabas, A T; Nowak, R A

    2016-01-01

    Extracellular matrix metalloproteinase inducer (EMMPRIN; BSG) regulates tissue remodeling through matrix metalloproteinases (MMPs). In human and non-human primates, endometrial remodeling is important for menstruation and the pathogenesis of endometriosis. We hypothesized that as in humans, BSG and MMPs are expressed in the endometrium of cycling baboons, and their expression is hormonally regulated by ovarian hormones, but endometriosis disrupts this regulation. BSG expression was evaluated in the baboon endometrium by q-PCR and immunohistochemistry. In the endometrium of control cycling animals, BSG mRNA levels were highest in late secretory stage tissue. BSG protein localized to glandular epithelial cells during the proliferative phase; whereas, secretory stage tissues expressed BSG in glandular and luminal epithelia with weak stromal staining. Several MMPs were differentially expressed throughout the menstrual cycle with the highest levels found during menstruation. In ovariectomized animals, BSG endometrial mRNA levels were highest with treatment of both estrogen and progesterone than that with only estrogen. Estrogen alone resulted in BSG protein localization primarily in the endometrial glandular epithelia, while estrogen and progesterone treatment displayed BSG protein localization in both the glandular and stromal cells. Exogenous hormone treatment resulted in differential expression patterns of all MMPs compared with the control cycling animals. In the eutopic endometrium of endometriotic animals, BSG mRNA levels and protein were elevated early but decreased later in disease progression. Endometriosis elevated the expression of all MMPs except MMP7 compared with the control animals. In baboons, BSG and MMP endometrial expression is regulated by both ovarian hormones, and their expression patterns are dysregulated in endometriotic animals. PMID:20841363

  17. Statistical strategies for averaging EC50 from multiple dose-response experiments.

    PubMed

    Jiang, Xiaoqi; Kopp-Schneider, Annette

    2015-11-01

    In most dose-response studies, repeated experiments are conducted to determine the EC50 value for a chemical, requiring averaging EC50 estimates from a series of experiments. Two statistical strategies, the mixed-effect modeling and the meta-analysis approach, can be applied to estimate average behavior of EC50 values over all experiments by considering the variabilities within and among experiments. We investigated these two strategies in two common cases of multiple dose-response experiments in (a) complete and explicit dose-response relationships are observed in all experiments and in (b) only in a subset of experiments. In case (a), the meta-analysis strategy is a simple and robust method to average EC50 estimates. In case (b), all experimental data sets can be first screened using the dose-response screening plot, which allows visualization and comparison of multiple dose-response experimental results. As long as more than three experiments provide information about complete dose-response relationships, the experiments that cover incomplete relationships can be excluded from the meta-analysis strategy of averaging EC50 estimates. If there are only two experiments containing complete dose-response information, the mixed-effects model approach is suggested. We subsequently provided a web application for non-statisticians to implement the proposed meta-analysis strategy of averaging EC50 estimates from multiple dose-response experiments.

  18. Effects of nonsteroidal anti-inflammatory meloxicam on stomach, kidney, and liver of rats.

    PubMed

    Burukoglu, Dilek; Baycu, Cengiz; Taplamacioglu, Fulya; Sahin, Erhan; Bektur, Ezgi

    2016-06-01

    Nonsteroidal anti-inflammatory (NSAI) drugs are the most commonly used group of drugs today. Increase in the use of standard NSAI for treating pain and inflammation was restricted by the fact that these drugs were proven to possibly cause gastrointestinal and renal toxicity. Meloxicam is a NSAI that has anti-inflammatory, analgesic, and antipyretic effects. This study aims to investigate the effects of meloxicam on stomach, kidney, and liver of rats under light microscopy level. Based on the light microscopic observations, mononuclear cell infiltration and pseudolobular formation was established in liver samples of animals in the experimental group. Metaplasia in surface and glandular epithelia and atrophy were observed in stomach samples. Glomerular stasis-related hypertrophy and focal interstitial nephritis were found in kidneys. It was concluded in this study that meloxicam might cause hepatotoxicity, nephrotoxicity, and gastric metaplasia in rats at a used dose and duration. © The Author(s) 2014.

  19. Reversible adrenal insufficiency and heterophile antibodies in a case of autoimmune polyendocrinopathy syndrome

    PubMed Central

    Kharb, Sandeep; Gundgurthi, Abhay; Dutta, Manoj K.; Garg, M. K.

    2013-01-01

    A 27-year-old male was admitted with diabetic ketoacidosis and altered sensorium with slurring of speech and ataxia. He was managed with intravenous insulin and fluids and later shifted to basal bolus insulin regimen and during further evaluation was diagnosed to be suffering from primary hypothyroidism and adrenal insufficiency. He was started on thyroxin replacement and steroids only during stress. After three months of follow up he was clinically euthyroid. His glycemic control was adequate on oral anti-hyperglycemic drugs and adrenal insufficiency recovered. However, his thyrotropin levels were persistently elevated on adequate replacement doses of thyroxin. His repeat TSH was estimated after precipitating serum with polyethylene glycol which revealed normal TSH. Here we report reversible adrenal insufficiency with hypothyroidism with falsely raised TSH because of presence of heterophile antibodies in a case of poly glandular endocrinopathy syndrome. PMID:24910843

  20. Reversible adrenal insufficiency and heterophile antibodies in a case of autoimmune polyendocrinopathy syndrome.

    PubMed

    Kharb, Sandeep; Gundgurthi, Abhay; Dutta, Manoj K; Garg, M K

    2013-12-01

    A 27-year-old male was admitted with diabetic ketoacidosis and altered sensorium with slurring of speech and ataxia. He was managed with intravenous insulin and fluids and later shifted to basal bolus insulin regimen and during further evaluation was diagnosed to be suffering from primary hypothyroidism and adrenal insufficiency. He was started on thyroxin replacement and steroids only during stress. After three months of follow up he was clinically euthyroid. His glycemic control was adequate on oral anti-hyperglycemic drugs and adrenal insufficiency recovered. However, his thyrotropin levels were persistently elevated on adequate replacement doses of thyroxin. His repeat TSH was estimated after precipitating serum with polyethylene glycol which revealed normal TSH. Here we report reversible adrenal insufficiency with hypothyroidism with falsely raised TSH because of presence of heterophile antibodies in a case of poly glandular endocrinopathy syndrome.

  1. Integration of co-localized glandular morphometry and protein biomarker expression in immunofluorescent images for prostate cancer prognosis

    NASA Astrophysics Data System (ADS)

    Scott, Richard; Khan, Faisal M.; Zeineh, Jack; Donovan, Michael; Fernandez, Gerardo

    2015-03-01

    Immunofluorescent (IF) image analysis of tissue pathology has proven to be extremely valuable and robust in developing prognostic assessments of disease, particularly in prostate cancer. There have been significant advances in the literature in quantitative biomarker expression as well as characterization of glandular architectures in discrete gland rings. However, while biomarker and glandular morphometric features have been combined as separate predictors in multivariate models, there is a lack of integrative features for biomarkers co-localized within specific morphological sub-types; for example the evaluation of androgen receptor (AR) expression within Gleason 3 glands only. In this work we propose a novel framework employing multiple techniques to generate integrated metrics of morphology and biomarker expression. We demonstrate the utility of the approaches in predicting clinical disease progression in images from 326 prostate biopsies and 373 prostatectomies. Our proposed integrative approaches yield significant improvements over existing IF image feature metrics. This work presents some of the first algorithms for generating innovative characteristics in tissue diagnostics that integrate co-localized morphometry and protein biomarker expression.

  2. The Barrett's Gland in Phenotype Space.

    PubMed

    McDonald, Stuart A C; Graham, Trevor A; Lavery, Danielle L; Wright, Nicholas A; Jansen, Marnix

    2015-01-01

    Barrett's esophagus is characterized by the erosive replacement of esophageal squamous epithelium by a range of metaplastic glandular phenotypes. These glandular phenotypes likely change over time, and their distribution varies along the Barrett's segment. Although much recent work has addressed Barrett's esophagus from the genomic viewpoint-its genotype space- the fact that the phenotype of Barrett's esophagus is nonstatic points to conversion between phenotypes and suggests that Barrett's esophagus also exists in phenotype space . Here we explore this latter concept, investigating the scope of glandular phenotypes in Barrett's esophagus and how they exist in physical and temporal space as well as their evolution and their life history. We conclude that individual Barrett's glands are clonal units; because of this important fact, we propose that it is the Barrett's gland that is the unit of selection in phenotypic and indeed neoplastic progression. Transition between metaplastic phenotypes may be governed by neutral drift akin to niche turnover in normal and dysplastic niches. In consequence, the phenotype of Barrett's glands assumes considerable importance, and we make a strong plea for the integration of the Barrett's gland in both genotype and phenotype space in future work.

  3. The sow endometrium at different stages of the oestrous cycle: immunohistochemical study on the distribution of SWC3-expressing cells (granulocytes, monocytes and macrophages).

    PubMed

    Kaeoket, K; Dalin, A M; Magnusson, U; Persson, E

    2001-10-01

    Uterine samples from sows taken immediately after slaughter at late di-oestrus, pro-oestrus, oestrus, early di-oestrus and di-ocstrus, were analysed by immunohistochemistry with an avidinbiotin-peroxidase method using a monoclonal antibody (anti-SWC3) to granulocyte, monocyte and macrophage populations. The endometrium was then examined by light microscopy. In the surface and glandular epithelium, the largest numbers of SWC3-expressing cells (P < or = 0.01 and P < or = 0.05) were found at oestrus, and at pro-oestrus and oestrus, respectively. The numbers of SWC3-expressing cells in the epithelium were positively correlated with the plasma levels of oestradiol-17beta. In the connective tissue of the subepithelial and glandular layers, no significant effect of the oestrous Cycle stage was found on the number of SWC3-expressing cells. The present study showed a variation in the distribution of SWC3-expressing cells in the sow endometrium, especially in the surface and glandular epithelium, during different stages of the oestrous cycle.

  4. Polarization spectrometry diagnostic of cervical pathological states of endometriosis

    NASA Astrophysics Data System (ADS)

    Yermolenko, S. B.; Peresunko, O. P.; Burkovets, D. N.

    2018-01-01

    The purpose of the study was to determine the histochemical and laser criteria for diagnosis of background, precancerous and endometrial cancer by the state of the cervical canal wall. The given data on the state of connective tissue in the endocervix can distinguish three differential prognostic possibilities: - prediction of the condition of the connective tissue of the endocervix of the normal endometrium without the possibility of differentiating the phases of the ovarian cycle; - prediction of the endocervix endotracheal connective tissue state of the endometrium as a separate process; - prediction for the condition of the connective tissue of the endocervix of the processes of expressed proliferation of the typical (glandular hyperplasia and glandular polyps) or atypical (adenocarcinoma) glandular first endometrial epithelial differentiation without the possibility of these processes among them. The stroke-scrape of the epithelium of the cervical canal (endocervix) allows the condition of the connective tissue to diagnose the processes of pronounced proliferation of the typical (hyperplasia, polyp) and atypical (adenocarcinoma) epithelium of the endometrium without the possibility of differentiating these processes among themselves.

  5. UV‐B is Required for Normal Development of Oil Glands in Ocimum basilicum L. (Sweet Basil)

    PubMed Central

    IOANNIDIS, DAPHNE; BONNER, LYNDA; JOHNSON, CHRISTOPHER B.

    2002-01-01

    Plants of Ocimum basilicum L. grown under glass were exposed to short treatments with supplementary UV‐B. The effect of UV‐B on volatile essential oil content was analysed and compared with morphological effects on the peltate and capitate glandular trichomes. In the absence of UV‐B, both peltate and capitate glands were incompletely developed in both mature and developing leaves, the oil sacs being wrinkled and only partially filled. UV‐B was found to have two main effects on the glandular trichomes. During the first 4 d of treatment, both peltate and capitate glands filled and their morphology reflected their ‘normal’ mature development as reported in the literature. During the following days there was a large increase in the number of broken oil sacs among the peltate glands as the mature glands broke open, releasing volatiles. Neither the number of glands nor the qualitative or quantitative composition of the volatiles was affected by UV‐B. There seems to be a requirement for UV‐B for the filling of the glandular trichomes of basil. PMID:12324268

  6. Image segmentation and 3D visualization for MRI mammography

    NASA Astrophysics Data System (ADS)

    Li, Lihua; Chu, Yong; Salem, Angela F.; Clark, Robert A.

    2002-05-01

    MRI mammography has a number of advantages, including the tomographic, and therefore three-dimensional (3-D) nature, of the images. It allows the application of MRI mammography to breasts with dense tissue, post operative scarring, and silicon implants. However, due to the vast quantity of images and subtlety of difference in MR sequence, there is a need for reliable computer diagnosis to reduce the radiologist's workload. The purpose of this work was to develop automatic breast/tissue segmentation and visualization algorithms to aid physicians in detecting and observing abnormalities in breast. Two segmentation algorithms were developed: one for breast segmentation, the other for glandular tissue segmentation. In breast segmentation, the MRI image is first segmented using an adaptive growing clustering method. Two tracing algorithms were then developed to refine the breast air and chest wall boundaries of breast. The glandular tissue segmentation was performed using an adaptive thresholding method, in which the threshold value was spatially adaptive using a sliding window. The 3D visualization of the segmented 2D slices of MRI mammography was implemented under IDL environment. The breast and glandular tissue rendering, slicing and animation were displayed.

  7. Poster - Thur Eve - 52: Clinical use of nanoDots: In-vivo dosimetry and treatment validation for stereotactic targets with VMAT techniques.

    PubMed

    Wierzbicki, W; Nicol, S; Furstoss, C; Brunet-Benkhoucha, M; Leduc, V

    2012-07-01

    A newly acquired nanoDot In-Light system was compared with TLD-100 dosimeters to confirm the treatment dose in the multiple cases: an electron eye treatment, H&N IMRT and VMAT validation for small targets. Eye tumour treatment with 9 MeV electrons A dose of 1.8 Gy per fraction was prescribed to the 85% isodose. The average dose measured by three TLDs and three Dots was 1.90 and 1.97 Gy. Both detectors overestimated dose, by 2.9% and 6.7% respectively. H&N IMRT treatment of skin cancer with 6 MV photons Dose per fraction is 2.5 Gy. The average doses measured by two TLDs and two Dots were 2.48 and 2.56 Gy, which represent errors of -0.8% and 2.2%, respectively. VMAT validation for small targets using an Agarose phantom, dose 15 Gy A single-tumour brain treatment was delivered using two coplanar arcs to an Agarise phantom containing a large plastic insert holding 3 nanoDots and 4 TLDs. The difference between the average Pinnacle dose and the average dose of the corresponding detectors was -0.6% for Dots and -1.7% for TLDs. A two-tumour brain treatment was delivered using three non-coplanar arcs. Small and large plastic inserts separated by 5 cm were used to validate the dose. The difference between the average Pinnacle dose and the average dose of the corresponding detectors was the following; small phantom 0.7% for Dots and 0.3% for TLDs, large phantom-1.9% for Dots and -0.6% for TLDs. In conclusion, nanoDot detectors are suitable for in-vivo dosimetry with photon and electron beams. © 2012 American Association of Physicists in Medicine.

  8. Therapeutics for Equine Gastric Ulcer Syndrome.

    PubMed

    Zavoshti, Fereydon Rezazadeh; Andrews, Frank M

    2017-04-01

    Equine gastric ulcer syndrome (EGUS) is an umbrella term used to describe ulcers in the nonglandular squamous and glandular mucosa, terminal esophagus, and proximal duodenum. Gastric ulcers in the squamous and glandular regions occur more often than esophageal or duodenal ulcers and likely have a different pathogenesis. At present, omeprazole is accepted globally as the best pharmacologic therapy for both regions of the stomach; however, the addition of coating agents and synthetic prostaglandins could add to its effectiveness in treatment of EGUS. Dietary and environmental management are necessary for prevention of recurrence. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Exposure of the Heart in Breast Cancer Radiation Therapy: A Systematic Review of Heart Doses Published During 2003 to 2013

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, Carolyn W., E-mail: carolyn.taylor@ctsu.ox.ac.uk; Wang, Zhe; Macaulay, Elizabeth

    Purpose: Breast cancer radiation therapy cures many women, but where the heart is exposed, it can cause heart disease. We report a systematic review of heart doses from breast cancer radiation therapy that were published during 2003 to 2013. Methods and Materials: Eligible studies were those reporting whole-heart dose (ie, dose averaged over the whole heart). Analyses considered the arithmetic mean of the whole-heart doses for the CT plans for each regimen in each study. We termed this “mean heart dose.” Results: In left-sided breast cancer, mean heart dose averaged over all 398 regimens reported in 149 studies from 28more » countries was 5.4 Gy (range, <0.1-28.6 Gy). In regimens that did not include the internal mammary chain (IMC), average mean heart dose was 4.2 Gy and varied with the target tissues irradiated. The lowest average mean heart doses were from tangential radiation therapy with either breathing control (1.3 Gy; range, 0.4-2.5 Gy) or treatment in the lateral decubitus position (1.2 Gy; range, 0.8-1.7 Gy), or from proton radiation therapy (0.5 Gy; range, 0.1-0.8 Gy). For intensity modulated radiation therapy mean heart dose was 5.6 Gy (range, <0.1-23.0 Gy). Where the IMC was irradiated, average mean heart dose was around 8 Gy and varied little according to which other targets were irradiated. Proton radiation therapy delivered the lowest average mean heart dose (2.6 Gy, range, 1.0-6.0 Gy), and tangential radiation therapy with a separate IMC field the highest (9.2 Gy, range, 1.9-21.0 Gy). In right-sided breast cancer, the average mean heart dose was 3.3 Gy based on 45 regimens in 23 studies. Conclusions: Recent estimates of typical heart doses from left breast cancer radiation therapy vary widely between studies, even for apparently similar regimens. Maneuvers to reduce heart dose in left tangential radiation therapy were successful. Proton radiation therapy delivered the lowest doses. Inclusion of the IMC doubled typical heart dose.« less

  10. An estimation of Canadian population exposure to cosmic rays.

    PubMed

    Chen, Jing; Timmins, Rachel; Verdecchia, Kyle; Sato, Tatsuhiko

    2009-08-01

    The worldwide average exposure to cosmic rays contributes to about 16% of the annual effective dose from natural radiation sources. At ground level, doses from cosmic ray exposure depend strongly on altitude, and weakly on geographical location and solar activity. With the analytical model PARMA developed by the Japan Atomic Energy Agency, annual effective doses due to cosmic ray exposure at ground level were calculated for more than 1,500 communities across Canada which cover more than 85% of the Canadian population. The annual effective doses from cosmic ray exposure in the year 2000 during solar maximum ranged from 0.27 to 0.72 mSv with the population-weighted national average of 0.30 mSv. For the year 2006 during solar minimum, the doses varied between 0.30 and 0.84 mSv, and the population-weighted national average was 0.33 mSv. Averaged over solar activity, the Canadian population-weighted average annual effective dose due to cosmic ray exposure at ground level is estimated to be 0.31 mSv.

  11. Properties of model-averaged BMDLs: a study of model averaging in dichotomous response risk estimation.

    PubMed

    Wheeler, Matthew W; Bailer, A John

    2007-06-01

    Model averaging (MA) has been proposed as a method of accounting for model uncertainty in benchmark dose (BMD) estimation. The technique has been used to average BMD dose estimates derived from dichotomous dose-response experiments, microbial dose-response experiments, as well as observational epidemiological studies. While MA is a promising tool for the risk assessor, a previous study suggested that the simple strategy of averaging individual models' BMD lower limits did not yield interval estimators that met nominal coverage levels in certain situations, and this performance was very sensitive to the underlying model space chosen. We present a different, more computationally intensive, approach in which the BMD is estimated using the average dose-response model and the corresponding benchmark dose lower bound (BMDL) is computed by bootstrapping. This method is illustrated with TiO(2) dose-response rat lung cancer data, and then systematically studied through an extensive Monte Carlo simulation. The results of this study suggest that the MA-BMD, estimated using this technique, performs better, in terms of bias and coverage, than the previous MA methodology. Further, the MA-BMDL achieves nominal coverage in most cases, and is superior to picking the "best fitting model" when estimating the benchmark dose. Although these results show utility of MA for benchmark dose risk estimation, they continue to highlight the importance of choosing an adequate model space as well as proper model fit diagnostics.

  12. Adrenaline (epinephrine) dosing period and survival after in-hospital cardiac arrest: a retrospective review of prospectively collected data.

    PubMed

    Warren, Sam A; Huszti, Ella; Bradley, Steven M; Chan, Paul S; Bryson, Chris L; Fitzpatrick, Annette L; Nichol, Graham

    2014-03-01

    Expert guidelines for treatment of cardiac arrest recommend administration of adrenaline (epinephrine) every three to five minutes. However, the effects of different dosing periods of epinephrine remain unclear. We sought to evaluate the association between epinephrine average dosing period and survival to hospital discharge in adults with an in-hospital cardiac arrest (IHCA). We performed a retrospective review of prospectively collected data on 20,909 IHCA events from 505 hospitals participating in the Get With The Guidelines-Resuscitation (GWTG-R) quality improvement registry. Epinephrine average dosing period was defined as the time between the first epinephrine dose and the resuscitation endpoint, divided by the total number of epinephrine doses received subsequent to the first epinephrine dose. Associations with survival to hospital discharge were assessed by using generalized estimating equations to construct multivariable logistic regression models. Compared to a referent epinephrine average dosing period of 4 to <5 min per dose, survival to hospital discharge was significantly higher in patients with the following epinephrine average dosing periods: for 6 to <7 min/dose, adjusted odds ratio [OR], 1.41 (95%CI: 1.12, 1.78); for 7 to <8 min/dose, adjusted OR, 1.30 (95%CI: 1.02, 1.65); for 8 to <9 min/dose, adjusted OR, 1.79 (95%CI: 1.38, 2.32); for 9 to <10 min/dose, adjusted OR, 2.17 (95%CI: 1.62, 2.92). This pattern was consistent for both shockable and non-shockable cardiac arrest rhythms. Less frequent average epinephrine dosing than recommended by consensus guidelines was associated with improved survival of in-hospital cardiac arrest. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  13. Influence of X-ray scatter radiation on image quality in Digital Breast Tomosynthesis (DBT)

    NASA Astrophysics Data System (ADS)

    Rodrigues, M. J.; Di Maria, S.; Baptista, M.; Belchior, A.; Afonso, J.; Venâncio, J.; Vaz, P.

    2017-11-01

    Digital breast tomosynthesis (DBT) is a quasi-three-dimensional imaging technique that was developed to solve the principal limitation of mammography, namely the overlapping tissue effect. This issue in standard mammography (SM) leads to two main problems: low sensitivity (difficulty to detect lesions) and low specificity (non-negligible percentage of false positives). Although DBT is now being introduced in clinical practice the features of this technique have not yet been fully and accurately assessed. Consequently, optimization studies in terms of choosing the most suitable parameters which maximize image quality according to the known limits of breast dosimetry are currently performing. In DBT, scatter radiation can lead to a loss of contrast and to an increase of image noise by reducing the signal-to-difference-noise ratio (SDNR) of a lesion. Moreover the use of an anti-scatter grid is a concern due to the low exposure of the photon flux available per projection. For this reason the main aim of this study was to analyze the influence of the scatter radiation on image quality and the dose delivered to the breast. In particular a detailed analysis of the scatter radiation on the optimal energy that maximizes the SDNR was performed for different monochromatic energies and voltages. To reach this objective the PenEasy Monte Carlo (MC) simulation tool imbedded in the general-purpose main program PENELOPE, was used. After a successful validation of the MC model with measurements, 2D projection images of primary, coherent and incoherent photons were obtained. For that, a homogeneous breast phantom (2, 4, 6, 8 cm) with 25%, 50% and 75% glandular compositions was used, including a 5 mm thick tumor. The images were generated for each monochromatic X-ray energies in the range from 16 keV to 32 keV. For each angular projection considered (25 angular projections covering an arc of 50°) the scatter-to-primary ratio (SPR), the mean glandular dose (MGD) and the signal difference to noise ratio (SDNR) were calculated with the aim to assess/determine in which conditions (i.e. energy, angular projection, breast thickness) the scatter radiation affects the image quality. The obtained results on the aforementioned quantities and topics will be reported.

  14. Effect of glandular kallikrein on distal nephron HCO3- secretion in rats and on HCO3- secretion in MDCK cells.

    PubMed

    Vallés, P; Ebner, S; Manucha, W; Gutierrez, L; Marin-Grez, M

    1997-11-01

    Renal kallikrein is localized in the connecting tubule cells and secreted into the tubular fluid at late distal nephron segments. The present experiments were performed to further test the hypothesis that renal kallikrein reduces bicarbonate secretion of cortical collecting duct (CCD). The effect of orthograde injections of pig pancreatic kallikrein (1 or 3 micrograms/ml) into the renal tubular system was investigated. Urine fractions (Fr) were collected after a 2-min stop flow. Changes in the urine fraction with respect to those in free-flow urine samples (Ff) were related to the respective polyfructosan (Inutest) ratio. Renal kallikrein activity (Fr:Ff kallikrein/ Fr:Ff polyfructosan) increased significantly in the first two urine fractions collected after glandular kallikrein administration (kallikrein, 1 microgram/ml, P < 0.05; kallikrein, 3 micrograms/ml, P < 0.01). HCO3- secretion of collecting ducts was significantly reduced dose dependently by orthograde and also reduced by retrograde pig pancreatic kallikrein administration. Release of kinins into the fractions was not affected by the retrograde kallikrein injection, even though the kallikrein activity increased considerably (2.26 +/- 0.2 vs. 1.55 +/- 0.2, P < 0.05). Adequacy of retrograde injections for delivering substances to the CCD was demonstrated by injecting colloidal mercury and detecting the appearance of this mercury in the renal cortex by transmission electron microscopy. The integrity of the renal tissue after a retrograde ureteral injection was confirmed by scanning electron microscopy. These results confirm and extend previous data (M. Marin-Grez and P. Vallés. Renal Physiol. Biochem. 17: 301-306, 1994; and M. Marin-Grez, P. Vallés, and P. Odigie. J. Physiol. 488: 163-170, 1995) showing that renal kallikrein reduces bicarbonate secretion at the CCD, probably by inhibiting HCO3- transported by a mechanism unrelated to its kininogenase activity. Support for this assessment was obtained in experiments testing the effect of kallikrein on the luminal bicarbonate secretion of a subpopulation of Madin-Darby canine kidney cells capable of extruding the anion. Kallikrein inhibited HCO3-/Cl- exchange, and the degree of inhibition was dose dependent. This inhibition occurred in the absence of kininogen in the bathing solution.

  15. Subspecific variation in the widespread burl-forming Arctostaphylos glandulosa

    USGS Publications Warehouse

    Keeley, Jon E.; Vasey, Michael C.; Parker, V. Thomas

    2007-01-01

    The genus Arctostaphylos consists mostly of chaparral shrubs known by the common name manzanita, and one of the widest ranging of these is A. glandulosa Eastw., distributed from Baja California to Oregon. Particularly in the southern half of its range it exhibits complex patterns of morphological variation that have long presented taxonomic challenges. Phenetic analysis of morphological traits from over 1400 individuals from throughout the range were used to examine intra- and inter-population patterns of variation. Multivariate ordination and hierarchical cluster analysis were used to determine phenetic patterns linked with ecological and geographical distributions. These analyses suggest the hypothesis that this species comprises two lineages with a common origin but divergent in the presence or absence of glandularity: A. glandulosa Eastw. subsp. glandulosa, characterized by branchlets with long glandular hairs, scabrous or pubescent leaves, and nascent inflorescences with mostly foliaceous bracts; and A. glandulosa Eastw. subsp. cushingiana(Eastw.) Keeley, Vasey and Parker comb. nov., with non-glandular tomentose branchlets, glabrate or pubescent leaves and either foliaceous or short deltoid bracts. Populations dominated by one or the other of these morphotypes occur throughout the range and tend to be separated by elevation or distance from the coast, although mixed populations occur where these taxa come together.Two other glandular subspecies are named here. One is A. glandulosa Eastw. subsp. leucophyllaKeeley, Vasey and Parker, subsp. nov., with intensely glaucous leaves and commonly with foliaceous bracts. A second glandular subspecies is A. glandulosa Eastw. subsp. atumescens Keeley, Vasey & Parker, subsp. nov., a narrowly distributed Baja California endemic similar to the nominate subspecies except that it lacks a basal burl and does not resprout after fire.Of the non-glandular tomentose taxa, in addition to A. glandulosa subsp cushingiana, several others are also recognized. One is A. glandulosa Eastw. subsp. crassifolia (Jepson) Wells, a well established coastal San Diego endemic recognized by darker and thicker leaves and smaller and flatter fruits. Another is a newly described taxon A. glandulosa Eastw. subsp. erecta Keeley, Vasey & Parker, subsp. nov., an endemic to northern Baja California recognized by the erect nascent inflorescenses. Two others have glabrate leaves and highly reduced deltoid often marcescent bracts; A. glandulosasubsp. adamsii (Munz) Wells, which has intensely glaucous leaves and is distributed from interior Riverside Co. south, and A. glandulosa Eastw. subsp. gabrielensis (Wells) Keeley, Vasey and Parker comb. nov., which has bright lustrous green leaves and greater fusion of nutlets, and is distributed from the interior San Gabriel Mountains of Los Angeles Co. north to the Sierra Madre Mountains of Santa Barbara Co. All non-glandular plants with long setose or villous hairs are A. glandulosa Eastw. subsp. mollis (Adams) Wells. This taxon includes plants with foliaceous as well as reduced bracts and is distributed throughout the Transverse Ranges from Santa Barbara to San Bernardino counties, with some outlying populations further south. This taxon shows a marked tendency for reduced stomatal densities on the upper leaf surface in the westernmost populations. Although all of the A. glandulosataxa described here are known from allopatric populations, intergradations of these closely related taxa occur and thus some populations reflect a mixture of traits and can not be assigned a unique name of practical value.

  16. Intercellular communication within the rat anterior pituitary: XIV electron microscopic and immunohistochemical study on the relationship between the agranular cells and GnRH neurons in the dorsal pars tuberalis of the pituitary gland.

    PubMed

    Shirasawa, Nobuyuki; Sakuma, Eisuke; Wada, Ikuo; Naito, Akira; Horiuchi, Osamu; Mabuchi, Yoshio; Kanai, Miharu; Herbert, Damon C; Soji, Tsuyoshi

    2007-11-01

    Although numerous investigators in 1970s to 1980s have reported the distribution of LH-RH nerve fibers in the median eminence, a few LH-RH fibers have been shown to be present in the pars tuberalis. The significance of the finding remains to be elucidated, and there are few studies on the distribution of LH-RH neurons in the pars tuberalis, especially in the dorsal pars tuberalis (DPT). Adult male Wistar-Imamichi rats were separated into two groups: one for electron microscopy and the other for immunohistochemistry to observe LH-RH and neurofilaments. Pituitary glands attached to the brain were fixed by perfusion, and the sections were prepared parallel to the sagittal plane. The typical glandular structure of the pars tuberalis was evident beneath the bottom floor of the third ventricle, and the thick glandular structure was present in the foremost region. Closer to the anterior lobe, the glandular structure changed to be a thin layer, and it was again observed at the posterior portion. Then the pituitary stalk was surrounded with the dorsal, lateral, and ventral pars tuberalis. LH-RH and neurofilaments fibers were noted in the bottom floor, and some of them vertically descended to the gland. Adjacent to the glandular folliculostellate cells in the pars tuberalis, Herring bodies with numerous dense granules invading into the gland were present between the pituitary stalk and DPT. It was postulated that the "message" carried by LH-RH might have been transmitted to the cells in the DPT to aid in the modulation of LH release. Copyright 2007 Wiley-Liss, Inc.

  17. Capitate glandular trichomes in Aldama discolor (Heliantheae - Asteraceae): morphology, metabolite profile and sesquiterpene biosynthesis.

    PubMed

    Bombo, A B; Appezzato-da-Glória, B; Aschenbrenner, A-K; Spring, O

    2016-05-01

    The capitate glandular trichome is the most common type described in Asteraceae species. It is known for its ability to produce various plant metabolites of ecological and economic importance, among which sesquiterpene lactones are predominant. In this paper, we applied microscopy, phytochemical and molecular genetics techniques to characterise the capitate glandular trichome in Aldama discolor, a native Brazilian species of Asteraceae, with pharmacological potential. It was found that formation of trichomes on leaf primordia of germinating seeds starts between 24 h and 48 h after radicle growth indicates germination. The start of metabolic activity of trichomes was indicated by separation of the cuticle from the cell wall of secretory cells at the trichome tip after 72 h. This coincided with the accumulation of budlein A, the major sesquiterpene lactone of A. discolor capitate glandular trichomes, in extracts of leaf primordia after 96 h. In the same timeframe of 72-96 h post-germination, gene expression studies showed up-regulation of the putative germacrene A synthase (pGAS2) and putative germacrene A oxidase (pGAO) of A. discolor in the transcriptome of these samples, indicating the start of sesquiterpene lactone biosynthesis. Sequencing of the two genes revealed high similarity to HaGAS and HaGAO from sunflower, which shows that key steps of this pathway are highly conserved. The processes of trichome differentiation, metabolic activity and genetic regulation in A. discolor and in sunflower appear to be typical for other species of the subtribe Helianthinae. © 2015 German Botanical Society and The Royal Botanical Society of the Netherlands.

  18. Vital-dye enhanced fluorescence imaging of gastrointestinal mucosa: metaplasia, neoplasia, inflammation

    PubMed Central

    Muldoon, Timothy J; Polydorides, Alexandros D; Maru, Dipen M; Harpaz, Noam; Harris, Michael T; Hofstettor, Wayne; Hiotis, Spiros P; Kim, Sanghyun A; Ky, Alex J; Anandasabapathy, Sharmila; Richards-Kortum, Rebecca

    2012-01-01

    Background Confocal endomicroscopy has revolutionized endoscopy by offering sub-cellular images of gastrointestinal epithelium; however, field-of-view is limited. There is a need for multi-scale endoscopy platforms that use widefield imaging to better direct placement of high-resolution probes. Design Feasibility Study Objective This study evaluates the feasibility of a single agent, proflavine hemisulfate, as a contrast medium during both widefield and high resolution imaging to characterize morphologic changes associated with a variety of gastrointestinal conditions. Setting U.T. M.D. Anderson Cancer Center (Houston, TX) and Mount Sinai Medical Center (New York, NY) Patients, Interventions, and Main Outcome Measurements Surgical specimens were obtained from 15 patients undergoing esophagectomy/colectomy. Proflavine, a vital fluorescent dye, was applied topically. Specimens were imaged with a widefield multispectral microscope and a high-resolution microendoscope. Images were compared to histopathology. Results Widefield-fluorescence imaging enhanced visualization of morphology, including the presence and spatial distribution of glands, glandular distortion, atrophy and crowding. High-resolution imaging of widefield-abnormal areas revealed that neoplastic progression corresponded to glandular heterogeneity and nuclear crowding in dysplasia, with glandular effacement in carcinoma. These widefield and high-resolution image features correlated well with histopathology. Limitations This imaging approach must be validated in vivo with a larger sample size. Conclusions Multi-scale proflavine-enhanced fluorescence imaging can delineate epithelial changes in a variety of gastrointestinal conditions. Distorted glandular features seen with widefield imaging could serve as a critical ‘bridge’ to high-resolution probe placement. An endoscopic platform combining the two modalities with a single vital-dye may facilitate point-of-care decision-making by providing real-time, in vivo diagnoses. PMID:22301343

  19. Vital-dye enhanced fluorescence imaging of GI mucosa: metaplasia, neoplasia, inflammation.

    PubMed

    Thekkek, Nadhi; Muldoon, Timothy; Polydorides, Alexandros D; Maru, Dipen M; Harpaz, Noam; Harris, Michael T; Hofstettor, Wayne; Hiotis, Spiros P; Kim, Sanghyun A; Ky, Alex Jenny; Anandasabapathy, Sharmila; Richards-Kortum, Rebecca

    2012-04-01

    Confocal endomicroscopy has revolutionized endoscopy by offering subcellular images of the GI epithelium; however, the field of view is limited. Multiscale endoscopy platforms that use widefield imaging are needed to better direct the placement of high-resolution probes. Feasibility study. This study evaluated the feasibility of a single agent, proflavine hemisulfate, as a contrast medium during both widefield and high-resolution imaging to characterize the morphologic changes associated with a variety of GI conditions. The University of Texas MD Anderson Cancer Center, Houston, Texas, and Mount Sinai Medical Center, New York, New York. PATIENTS, INTERVENTIONS, AND MAIN OUTCOME MEASUREMENTS: Resected specimens were obtained from 15 patients undergoing EMR, esophagectomy, or colectomy. Proflavine hemisulfate, a vital fluorescent dye, was applied topically. The specimens were imaged with a widefield multispectral microscope and a high-resolution microendoscope. The images were compared with histopathologic examination. Widefield fluorescence imaging enhanced visualization of morphology, including the presence and spatial distribution of glands, glandular distortion, atrophy, and crowding. High-resolution imaging of widefield abnormal areas revealed that neoplastic progression corresponded to glandular heterogeneity and nuclear crowding in dysplasia, with glandular effacement in carcinoma. These widefield and high-resolution image features correlated well with the histopathologic features. This imaging approach must be validated in vivo with a larger sample size. Multiscale proflavine-enhanced fluorescence imaging can delineate epithelial changes in a variety of GI conditions. Distorted glandular features seen with widefield imaging could serve as a critical bridge to high-resolution probe placement. An endoscopic platform combining the two modalities with a single vital dye may facilitate point-of-care decision making by providing real-time, in vivo diagnoses. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  20. Determination of the Elasticity of Breast Tissue during the Menstrual Cycle Using Real-Time Shear Wave Elastography.

    PubMed

    Li, Xiang; Wang, Jian-Nan; Fan, Zhi-Ying; Kang, Shu; Liu, Yan-Jun; Zhang, Yi-Xia; Wang, Xue-Mei

    2015-12-01

    We examined breast tissue elasticity during the menstrual cycle using real-time shear wave elastography (RT-SWE), a recent technique developed for soft tissue imaging. Written informed consent for RT-SWE was obtained from all eligible patients, who were healthy women aged between 19 and 52 y. Young's moduli of the breast tissue in the early follicular, late phase and luteal phase were compared. There were no significant differences in the mean, maximum and minimum elasticity values (Emean, Emax and Emin) and standard deviation (ESD). RT-SWE of glandular tissue revealed that ESD was increased in the early follicular phase compared with the luteal phase. Means ± SD of Emin, Emax and Emean in glandular tissue were 5.174 ± 2.138, 8.308 ± 3.166 and 6.593 ± 2.510, respectively, and in adipose tissue, 3.589 ± 2.083, 6.733 ± 3.522 and 4.857 ± 2.564, respectively. There were no significant differences in stiffness between glandular and adipose tissues throughout the menstrual cycle, but glandular tissue stiffness was lower in the luteal phase than in the early follicular phase. On the basis of these observations in normal healthy women, we believe we have obtained sufficient information to establish the baseline changes in human breast elasticity during the menstrual cycle. In the future, we intend to compare the elasticity values of healthy breast tissue with those of breast tissue affected by various pathologies. Our results reveal the significant potential of RT-SWE in the rapid and non-invasive clinical diagnosis of breast diseases, such as breast cancers. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. Glandular kallikrein in the innate immune system of Atlantic salmon (Salmo salar).

    PubMed

    Haussmann, D; Figueroa, J

    2011-02-15

    Glandular Kallikrein is a serine-protease with trypsin-like activity and is able to generate bioactive peptides from inactive precursors. We have evaluated the presence of this protease in the different organs of the Atlantic salmon (Salmo salar). The results clearly indicate that GK and PRL are generated in the same pituitary cells based on a co-localization by confocal microscopy. Based on probed cross-reactivity between C. striata and C. carpio glandular anti-GK antibodies, we used a homologous antibody to detect the presence of GK in several salmon tissues. We have evaluated the GK expression in healthy and defied fish. P. salmonis and V. ordalii. The GK immunoreaction in organs such as leukocytes, gills and skin is considerably increased in defied fish compared to healthy fish. This increase was present in the cells of the excretory kidney and in the intercellular tissue, where the development of hematopoietic and lymphocytic lines in fish take place. One of the most interesting organs to study was the skin, bearing in mind that this is a primary barrier to all pathogens. The skin of the defied fish exhibited an increase in immunoreactivity for glandular kallikrein similar to the protease found in mucus. An immunoreactive tissue kallikrein-like protein was identified and partially separated by perfusion chromatography. Enzymatic activity of salmon muscle prokallikrein was determined before and after trypsin activation. Kallikrein activity was characterized with respect to their ability to cleave the chromogenic leaving group, p-nitroanilide, from the peptidyl kallikrein and trypsin substrate. These findings constitute a important contribution to reveal the role of kallikrein in the innate immune system of fish. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. Radiation exposure from consumer products and miscellaneous sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1977-01-01

    This review of the literature indicates that there is a variety of consumer products and miscellaneous sources of radiation that result in exposure to the U.S. population. A summary of the number of people exposed to each such source, an estimate of the resulting dose equivalents to the exposed population, and an estimate of the average annual population dose equivalent are tabulated. A review of the data in this table shows that the total average annual contribution to the whole-body dose equivalent of the U.S. population from consumer products is less than 5 mrem; about 70 percent of this arisesmore » from the presence of naturally-occurring radionuclides in building materials. Some of the consumer product sources contribute exposure mainly to localized tissues or organs. Such localized estimates include: 0.5 to 1 mrem to the average annual population lung dose equivalent (generalized); 2 rem to the average annual population bronchial epithelial dose equivalent (localized); and 10 to 15 rem to the average annual population basal mucosal dose equivalent (basal mucosa of the gum). Based on these estimates, these sources may be grouped or classified as those that involve many people and the dose equivalent is relative large or those that involve many people but the dose equivalent is relatively small, or the dose equivalent is relatively large but the number of people involved is small.« less

  3. Investigation of natural effective gamma dose rates case study: Ardebil Province in Iran

    PubMed Central

    2012-01-01

    Gamma rays pose enough energy to induce chemical changes that may be biologically important for the normal functioning of body cells. The external exposure of human beings to natural environmental gamma radiation normally exceeds that from all man-made sources combined. In this research natural background gamma dose rates and corresponding annual effective doses were determined for selected cities of Ardebil province. Outdoor gamma dose rates were measured using an Ion Chamber Survey Meter in 105 locations in selected districts. Average absorbed doses for Ardebil, Sar-Ein, Germy, Neer, Shourabil Recreational Lake, and Kosar were determined as 265, 219, 344, 233, 352, and 358 nSv/h, respectively. Although dose rates recorded for Germi and Kosar are comparable with some areas with high natural radiation background, however, the dose rates in other districts are well below the levels reported for such locations. Average annual effective dose due to indoor and outdoor gamma radiation for Ardebil province was estimated as 1.73 (1.35–2.39) mSv, which is on average 2 times higher than the world population weighted average. PMID:23369115

  4. In utero and lactational exposure to low-dose genistein-vinclozolin mixture affects the development and growth factor mRNA expression of the submandibular salivary gland in immature female rats.

    PubMed

    Kouidhi, Wided; Desmetz, Catherine; Nahdi, Afef; Bergès, Raymond; Cravedi, Jean-Pierre; Auger, Jacques; El May, Michèle; Canivenc-Lavier, Marie Chantal

    2012-06-01

    It has been suggested that hormonally controlled submandibular salivary gland (SSG) development and secretions may be affected by endocrine disruptor compounds. We investigated the effects of oral gestation-lactation exposure to 1 mg/kg body weight daily dose of the estrogenic soy-isoflavone genistein and/or the anti-androgenic food contaminant vinclozolin in female rats. The SSGs of female offspring were collected at postnatal day 35 to study gland morphogenesis and mRNA expression of sex-hormone receptors and endocrine growth factors as sex-dependent biomarkers. Because of high expression in neonatal SSG, mRNA expression of transforming growth factor α was also studied. Exposure to genistein, vinclozolin, or a genistein+vinclozolin mixture resulted in significantly lower numbers of striated ducts linked to an increase in their area and lower acinar proliferation (Ki-67-positive nuclei). Exposure to the mixture had the highest significant effects, which were particularly associated with repression of epidermal growth factor, nerve growth factor, and transforming growth factor α expression. In conclusion, early exposure to low doses of genistein and vinclozolin can affect glandular structure and endocrine gene mRNA expression in prepubertal SSG in female rats, and the effects are potentialized by the genistein+vinclozolin mixture. Our study provides the first evidence that SSG are targeted by both estrogenic and anti-androgenic disrupting compounds and are more sensitive to mixtures.

  5. Does Iterative Reconstruction Lower CT Radiation Dose: Evaluation of 15,000 Examinations

    PubMed Central

    Noël, Peter B.; Renger, Bernhard; Fiebich, Martin; Münzel, Daniela; Fingerle, Alexander A.; Rummeny, Ernst J.; Dobritz, Martin

    2013-01-01

    Purpose Evaluation of 15,000 computed tomography (CT) examinations to investigate if iterative reconstruction (IR) reduces sustainably radiation exposure. Method and Materials Information from 15,000 CT examinations was collected, including all aspects of the exams such as scan parameter, patient information, and reconstruction instructions. The examinations were acquired between January 2010 and December 2012, while after 15 months a first generation IR algorithm was installed. To collect the necessary information from PACS, RIS, MPPS and structured reports a Dose Monitoring System was developed. To harvest all possible information an optical character recognition system was integrated, for example to collect information from the screenshot CT-dose report. The tool transfers all data to a database for further processing such as the calculation of effective dose and organ doses. To evaluate if IR provides a sustainable dose reduction, the effective dose values were statistically analyzed with respect to protocol type, diagnostic indication, and patient population. Results IR has the potential to reduce radiation dose significantly. Before clinical introduction of IR the average effective dose was 10.1±7.8mSv and with IR 8.9±7.1mSv (p*=0.01). Especially in CTA, with the possibility to use kV reduction protocols, such as in aortic CTAs (before IR: average14.2±7.8mSv; median11.4mSv /with IR:average9.9±7.4mSv; median7.4mSv), or pulmonary CTAs (before IR: average9.7±6.2mSV; median7.7mSv /with IR: average6.4±4.7mSv; median4.8mSv) the dose reduction effect is significant(p*=0.01). On the contrary for unenhanced low-dose scans of the cranial (for example sinuses) the reduction is not significant (before IR:average6.6±5.8mSv; median3.9mSv/with IR:average6.0±3.1mSV; median3.2mSv). Conclusion The dose aspect remains a priority in CT research. Iterative reconstruction algorithms reduce sustainably and significantly radiation dose in the clinical routine. Our results illustrate that not only in studies with a limited number of patients but also in the clinical routine, IRs provide long-term dose saving. PMID:24303035

  6. Does iterative reconstruction lower CT radiation dose: evaluation of 15,000 examinations.

    PubMed

    Noël, Peter B; Renger, Bernhard; Fiebich, Martin; Münzel, Daniela; Fingerle, Alexander A; Rummeny, Ernst J; Dobritz, Martin

    2013-01-01

    Evaluation of 15,000 computed tomography (CT) examinations to investigate if iterative reconstruction (IR) reduces sustainably radiation exposure. Information from 15,000 CT examinations was collected, including all aspects of the exams such as scan parameter, patient information, and reconstruction instructions. The examinations were acquired between January 2010 and December 2012, while after 15 months a first generation IR algorithm was installed. To collect the necessary information from PACS, RIS, MPPS and structured reports a Dose Monitoring System was developed. To harvest all possible information an optical character recognition system was integrated, for example to collect information from the screenshot CT-dose report. The tool transfers all data to a database for further processing such as the calculation of effective dose and organ doses. To evaluate if IR provides a sustainable dose reduction, the effective dose values were statistically analyzed with respect to protocol type, diagnostic indication, and patient population. IR has the potential to reduce radiation dose significantly. Before clinical introduction of IR the average effective dose was 10.1±7.8mSv and with IR 8.9±7.1mSv (p*=0.01). Especially in CTA, with the possibility to use kV reduction protocols, such as in aortic CTAs (before IR: average14.2±7.8mSv; median11.4mSv /with IR:average9.9±7.4mSv; median7.4mSv), or pulmonary CTAs (before IR: average9.7±6.2mSV; median7.7mSv /with IR: average6.4±4.7mSv; median4.8mSv) the dose reduction effect is significant(p*=0.01). On the contrary for unenhanced low-dose scans of the cranial (for example sinuses) the reduction is not significant (before IR:average6.6±5.8mSv; median3.9mSv/with IR:average6.0±3.1mSV; median3.2mSv). The dose aspect remains a priority in CT research. Iterative reconstruction algorithms reduce sustainably and significantly radiation dose in the clinical routine. Our results illustrate that not only in studies with a limited number of patients but also in the clinical routine, IRs provide long-term dose saving.

  7. Development and Structure of Internal Glands and External Glandular Trichomes in Pogostemon cablin

    PubMed Central

    Guo, Jiansheng; Yuan, Yongming; Liu, Zhixue; Zhu, Jian

    2013-01-01

    Pogostemon cablin possesses two morphologically and ontogenetically different types of glandular trichomes, one type of bristle hair on the surfaces of leaves and stems and one type of internal gland inside the leaves and stems. The internal gland originates from elementary meristem and is associated with the biosynthesis of oils present inside the leaves and stems. However, there is little information on mechanism for the oil biosynthesis and secretion inside the leaves and stems. In this study, we identified three kinds of glandular trichome types and two kinds of internal gland in the Pogostemon cablin. The oil secretions from internal glands of stems and leaves contained lipids, flavones and terpenes. Our results indicated that endoplasmic reticulum and plastids and vacuoles are likely involved in the biosynthesis of oils in the internal glands and the synthesized oils are transported from endoplasmic reticulum to the cell wall via connecting endoplasmic reticulum membranes to the plasma membrane. And the comparative analysis of the development, distribution, histochemistry and ultrastructures of the internal and external glands in Pogostemon cablin leads us to propose that the internal gland may be a novel secretory structure which is different from external glands. PMID:24205002

  8. Inhibition of extracellular matrix mediated TGF-β signalling suppresses endometrial cancer metastasis

    PubMed Central

    Sahoo, Subhransu S.; Quah, Min Yuan; Nielsen, Sarah; Atkins, Joshua; Au, Gough G.; Cairns, Murray J.; Nahar, Pravin; Lombard, Janine M.; Tanwar, Pradeep S.

    2017-01-01

    Although aggressive invasion and distant metastases are an important cause of morbidity and mortality in patients with endometrial cancer (EC), the requisite events determining this propensity are currently unknown. Using organotypic three-dimensional culture of endometrial cancer cell lines, we demonstrated anti-correlated TGF-β signalling gene expression patterns that arise among extracellular matrix (ECM)-attached cells. TGF-β pathway seemed to be active in EC cells forming non-glandular colonies in 3D-matrix but weaker in glandular colonies. Functionally we found that out of several ECM proteins, fibronectin relatively promotes Smad phosphorylation suggesting a potential role in regulating TGF-β signalling in non-glandular colonies. Importantly, alteration of TGF-β pathway induced EMT and MET in both type of colonies through slug protein. The results exemplify a crucial role of TGF-β pathway during EC metastasis in human patients and inhibition of the pathway in a murine model impaired tumour cell invasion and metastasis depicting an attractive target for therapeutic intervention of malignant tumour progression. These findings provide key insights into the role of ECM-derived TGF-β signalling to promote endometrial cancer metastasis and offer an avenue for therapeutic targeting of microenvironment derived signals along with tumour cells. PMID:29069715

  9. GA3 and other signal regulators (MeJA and IAA) improve xanthumin biosynthesis in different manners in Xanthium strumarium L.

    PubMed

    Li, Changfu; Chen, Fangfang; Zhang, Yansheng

    2014-08-25

    Xanthanolides from Xanthium strumarium L. exhibit various pharmacological activities and these compounds are mainly produced in the glandular trichomes of aerial plant parts. The regulation of xanthanolide biosynthesis has never been reported in the literature. In this study, the effects of phytohormonal stimulation on xanthumin (a xanthanolide compound) biosynthesis, glandular trichomes and germacrene A synthase (GAS) gene expression in X. strumarium L. young leaves were investigated. The exogenous applications of methyl jasmonate (MeJA), indole-3-acetic acid (IAA), and gibberrellin A3 (GA3) at appropriate concentrations were all found to improve xanthumin biosynthesis, but in different ways. It was suggested that a higher gland density stimulated by MeJA (400 µM) or IAA (200 µM) treatment caused at least in part an improvement in xanthumin production, whereas GA3 (10 µM) led to an improvement by up-regulating xanthumin biosynthetic genes within gland cells, not by forming more glandular trichomes. Compared to the plants before the flowering stage, plants that had initiated flowering showed enhanced xanthumin biosynthesis, but no higher gland density, an effect was similar to that caused by exogenous GA3 treatment.

  10. The Primary Duct of Bothrops jararaca Glandular Apparatus Secretes Toxins

    PubMed Central

    Sakai, Fernanda; Portes-Junior, José Antonio; Godoy Viana, Luciana; Mendes Carneiro, Sylvia; Perales, Jonas; Yamanouye, Norma

    2018-01-01

    Despite numerous studies concerning morphology and venom production and secretion in the main venom gland (and some data on the accessory gland) of the venom glandular apparatus of Viperidae snakes, the primary duct has been overlooked. We characterized the primary duct of the Bothrops jararaca snake by morphological analysis, immunohistochemistry and proteomics. The duct has a pseudostratified epithelium with secretory columnar cells with vesicles of various electrondensities, as well as mitochondria-rich, dark, basal, and horizontal cells. Morphological analysis, at different periods after venom extraction, showed that the primary duct has a long cycle of synthesis and secretion, as do the main venom and accessory glands; however, the duct has a mixed mode venom storage, both in the lumen and in secretory vesicles. Mouse anti-B. jararaca venom serum strongly stained the primary duct’s epithelium. Subsequent proteomic analysis revealed the synthesis of venom toxins—mainly C-type lectin/C-type lectin-like proteins. We propose that the primary duct’s toxin synthesis products complement the final venom bolus. Finally, we hypothesize that the primary duct and the accessory gland (components of the venom glandular apparatus) are part of the evolutionary path from a salivary gland towards the main venom gland. PMID:29533989

  11. Cloning of a sesquiterpene synthase from Lavandula x intermedia glandular trichomes.

    PubMed

    Sarker, Lukman S; Demissie, Zerihun A; Mahmoud, Soheil S

    2013-11-01

    The essential oil (EO) of Lavandula is dominated by monoterpenes, but can also contain small amounts of sesquiterpenes, depending on species and environmental conditions. For example, the sesquiterpene 9-epi-caryophyllene can make up to 8 % of the EO in a few species, including those commercially propagated for EO production. Here, we report the cloning and functional characterization of 9-epi-caryophyllene synthase (LiCPS) from the glandular trichomes of Lavandula x intermedia, cv. Grosso. The 1,617 bp open reading frame of LiCPS, which did not encode a transit peptide, was expressed in Escherichia coli and the recombinant protein purified by Ni-NTA agarose affinity chromatography. The ca. 60 kDa recombinant protein specifically converted farnesyl diphosphate to 9-epi-caryophyllene. LiCPS also produced a few monoterpenes when assayed with the monoterpene precursor geranyl diphosphate (GPP), but--unlike most monoterpene synthases--was not able to derive detectable amounts of any products from the cis isomer of GPP, neryl diphosphate. The LiCPS transcripts accumulated in developing L. x intermedia flowers and were highly enriched in glandular trichomes, but were not detected in leaves suggesting that the transcriptional expression of this gene is spatially and developmentally regulated.

  12. Microscopic characters of the leaf and stem of Lavandula dentata L. (Lamiaceae).

    PubMed

    do Rocio Duarte, Márcia; Carvalho de Souza, Danielle

    2014-08-01

    Lavandula dentata L. is an aromatic plant used in folk medicine for different purposes and, for this reason, phytochemical surveys have been carried out in the search for bioactive substances aiming to support its uses. Since there is little knowledge on the structural aspects of L. dentata, this work has studied the anatomical characters of the leaf and stem using light and scanning electron microscopy, in order to assist the species identification. As a result, there are different types of trichomes: capitate glandular with uni- or bicellular head, peltate glandular with multicellular head, and branched non-glandular. The leaf is hypostomatic showing diacytic stomata. The epidermis is uniseriate and coated with striate cuticle. The mesophyll is dorsiventral and the midrib is concave-convex and traversed by a single collateral vascular bundle. The stem is quadrangular and has alternating strands of collenchyma and cortical parenchyma as well as a typical endodermis in the cortex. The phloem and xylem cylinders are traversed by narrow rays and there is an incomplete sclerenchymatic sheath adjoining the phloem. These results are a novelty for the species and contribute to distinguish it from other lavenders. © 2014 Wiley Periodicals, Inc.

  13. A cold-tolerant evergreen interspecific hybrid of Ocimum kilimandscharicum and Ocimum basilicum: analyzing trichomes and molecular variations.

    PubMed

    Dhawan, Sunita Singh; Shukla, Preeti; Gupta, Pankhuri; Lal, R K

    2016-05-01

    Ocimum (Lamiaceae) is an important source of essential oils and aroma chemicals especially eugenol, methyl eugenol, linalool, methyl chavicol etc. An elite evergreen hybrid has been developed from Ocimum kilimandscharicum and Ocimum basilicum, which demonstrated adaptive behavior towards cold stress. A comparative molecular analysis has been done through RAPD, AFLP, and ISSR among O. basilicum and O. kilimandscharicum and their evergreen cold-tolerant hybrid. The RAPD and AFLP analyses demonstrated similar results, i.e., the hybrid of O. basilicum and O. kilimandscharicum shares the same cluster with O. kilimandscharicum, while O. basilicum behaves as an outgroup, whereas in ISSR analysis, the hybrid genotype grouped in the same cluster with O. basilicum. Ocimum genotypes were analyzed and compared for their trichome density. There were distinct differences on morphology, distribution, and structure between the two kinds of trichomes, i.e., glandular and non-glandular. Glandular trichomes contain essential oils, polyphenols, flavonoids, and acid polysaccharides. Hair-like trichomes, i.e., non-glandular trichomes, help in keeping the frost away from the living surface cells. O. basilicum showed less number of non-glandular trichomes on leaves compared to O. kilimandscharicum and the evergreen cold-tolerant hybrid. Trichomes were analyzed in O. kilimandscharicum, O. basilicum, and their hybrid. An increased proline content at the biochemical level represents a higher potential to survive in a stress condition like cold stress. In our analysis, the proline content is quite higher in tolerant variety O. kilimandscharicum, low in susceptible variety O. basilicum, and intermediate in the hybrid. Gene expression analysis was done in O. basilicum, O. kilimandscharicum and their hybrid for TTG1, GTL1, and STICHEL gene locus which regulates trichome development and its formation and transcription factors WRKY and MPS involved in the regulation of plant responses to freezing and cold. The analysis showed that O. kilimandscharicum and the hybrid were very close to each other but O. basilicum was more distinct in all respects. The overexpression of the WRKY coding gene showed high expression in the hybrid as compared to O. kilimandscharicum and O. basilicum and the transcription factor microspore-specific (MPS) promoter has also shown overexpression in the hybrid for its response against cold stress. The developed evergreen interspecific hybrid may thus provide a base to various industries which are dependent upon the bioactive constituents of Ocimum species.

  14. SU-E-T-579: Impact of Cylinder Size in High-Dose Rate Brachytherapy (HDRBT) for Primary Cancer in the Vagina

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, H; Gopalakrishnan, M; Lee, P

    2014-06-01

    Purpose: To evaluate the dosimetric impact of cylinder size in high dose rate Brachytherapy for primary vaginal cancers. Methods: Patients treated with HDR vaginal vault radiation in a list of cylinders ranging from 2.5 to 4 cm in diameter at 0.5 cm increment were analyzed. All patients’ doses were prescribed at the 0.5 cm from the vaginal surface with different treatment lengths. A series of reference points were created to optimize the dose distribution. The fraction dose was 5.5 Gy, the treatment was repeated for 4 times in two weeks. A cylinder volume was contoured in each case according tomore » the prescribed treatment length, and then expanded to 5 mm to get a volume Cylinder-5mm-exp. A volume of PTV-Eval was obtained by subtracting the cylinder volume from the Cylinder-5mm-exp. The shell volume, PTV-Eval serves as the target volume for dosimetric evaluation. Results: DVH curves and average doses of PTV-Eval were obtained. Our results indicated that the DVH curves shifted toward higher dose side when larger cylinder was used instead of smaller ones. When 3.0 cm cylinder was used instead of 2.5 cm, for 3.0 cm treatment length, the average dose only increased 1%, from 790 to 799 cGy. However, the average doses for 3.5 and 4 cm cylinders respectively are 932 and 1137 cGy at the same treatment length. For 5.0 cm treatment length, the average dose is 741 cGy for 2.5 cm cylinder, and 859 cGy for 3 cm cylinder. Conclusion: Our data analysis suggests that for the vaginal intracavitary HDRBT, the average dose is at least 35% larger than the prescribed dose in the studied cases; the size of the cylinder will impact the dose delivered to the target volume. The cylinder with bigger diameter tends to deliver larger average dose to the PTV-Eval.« less

  15. Library based x-ray scatter correction for dedicated cone beam breast CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shi, Linxi; Zhu, Lei, E-mail: leizhu@gatech.edu

    Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correctionmore » on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors’ method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors’ method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal views. Conclusions: The library-based scatter correction does not require increase in radiation dose or hardware modifications, and it improves over the existing methods on implementation simplicity and computational efficiency. As demonstrated through patient studies, the authors’ approach is effective and stable, and is therefore clinically attractive for CBBCT imaging.« less

  16. Library based x-ray scatter correction for dedicated cone beam breast CT

    PubMed Central

    Shi, Linxi; Karellas, Andrew; Zhu, Lei

    2016-01-01

    Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the geant4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors’ method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors’ method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal views. Conclusions: The library-based scatter correction does not require increase in radiation dose or hardware modifications, and it improves over the existing methods on implementation simplicity and computational efficiency. As demonstrated through patient studies, the authors’ approach is effective and stable, and is therefore clinically attractive for CBBCT imaging. PMID:27487870

  17. Tailored breast cancer screening program with microdose mammography, US, and MR Imaging: short-term results of a pilot study in 40-49-year-old women.

    PubMed

    Venturini, Elena; Losio, Claudio; Panizza, Pietro; Rodighiero, Maria Grazia; Fedele, Isabella; Tacchini, Simona; Schiani, Elena; Ravelli, Silvia; Cristel, Giulia; Panzeri, Marta Maria; De Cobelli, Francesco; Del Maschio, Alessandro

    2013-08-01

    To evaluate the feasibility, performance, and cost of a breast cancer screening program aimed at 40-49-year-old women and tailored to their risk profile with supplemental ultrasonography (US) and magnetic resonance (MR) imaging. The institutional review board approved this study, and informed written consent was obtained. A total of 3017 40-49-year-old women were invited to participate. The screening program was tailored to lifetime risk (Gail test) and mammographic density (according to Breast Imaging Reporting and Data Systems [BI-RADS] criteria) with supplemental US or MR imaging and bilateral two-view microdose mammography. The indicators suggested by European guidelines, US incremental cancer detection rate (CDR), and estimated costs were evaluated. A total of 1666 women (67.5% participation rate) were recruited. The average lifetime risk of breast cancer was 11.6%, and nine women had a high risk of breast cancer; 917 women (55.0%) had a high density score (BI-RADS density category 3 or 4). The average glandular dose for screening examinations was 1.49 mGy. Screening US was performed in 835 study participants (50.1%), mostly due to high breast density (800 of 1666 women [48.0%]). Screening MR imaging was performed in nine women (0.5%) at high risk for breast cancer. Breast cancer was diagnosed in 14 women (8.4 cases per 1000 women). Twelve diagnoses were made with microdose mammography, and two were made with supplemental US in dense breasts (2.4 cases per 1000 women). All patients were submitted for surgery, and 10 underwent breast-conserving surgery. The sentinel lymph node was evaluated in 11 patients, resulting in negative findings in six. Pathologic analysis resulted in the diagnosis of four ductal carcinomas in situ and 10 invasive carcinomas (five at stage I). A tailored breast cancer screening program in 40-49-year-old women yielded a greater-than-expected number of cancers, most of which were low-stage disease.

  18. [Digital breast tomosynthesis : technical principles, current clinical relevance and future perspectives].

    PubMed

    Hellerhoff, K

    2010-11-01

    In recent years digital full field mammography has increasingly replaced conventional film mammography. High quality imaging is guaranteed by high quantum efficiency and very good contrast resolution with optimized dosing even for women with dense glandular tissue. However, digital mammography remains a projection procedure by which overlapping tissue limits the detectability of subtle alterations. Tomosynthesis is a procedure developed from digital mammography for slice examination of breasts which eliminates the effects of overlapping tissue and allows 3D imaging of breasts. A curved movement of the X-ray tube during scanning allows the acquisition of many 2D images from different angles. Subseqently, reconstruction algorithms employing a shift and add method improve the recognition of details at a defined level and at the same time eliminate smear artefacts due to overlapping structures. The total dose corresponds to that of conventional mammography imaging. The technical procedure, including the number of levels, suitable anodes/filter combinations, angle regions of images and selection of reconstruction algorithms, is presently undergoing optimization. Previous studies on the clinical value of tomosynthesis have examined screening parameters, such as recall rate and detection rate as well as information on tumor extent for histologically proven breast tumors. More advanced techniques, such as contrast medium-enhanced tomosynthesis, are presently under development and dual-energy imaging is of particular importance.

  19. Safety of sucrose esters from Physalis peruviana L. in a 28-day repeated-dose study in mice.

    PubMed

    Ocampo, Yanet C; Caro, Daneiva C; Rivera, David E; Franco, Luis A

    2017-06-01

    Although extracts and consumed foods from Physalis species contain sucrose esters from their glandular trichomes, there is no experimental data available on their toxicological effects. As peruvioses A and B isolated from Physalis peruviana L. calyces have proved to be effective anti-inflammatory and immunomodulatory compounds, this work aimed to investigate their sub-acute toxicity study and genotoxicity. For this, CD-1(ICR) mice were treated intraperitoneally with peruvioses at doses of 2.5, 5, and 10mg/kg/day for 28 consecutive days, to simulate therapeutic and over-therapeutic dosage levels. At the end of the treatment, animals were sacrificed and their organs weighted, and blood and tissue samples were collected. Toxicological endpoints included clinical signs; food consumption; body and organ weights; hematological and biochemical parameters; as well as macroscopic and microscopic examination of tissues. The results showed no significant differences between treated animals and control group at macroscopic, histological, molecular, and biochemical levels. In addition, a combination of mammalian erythrocyte micronucleus test, comet assay in peripheral blood cells, and Ames test, did not reveal genotoxic effects induced by peruvioses. Taken together, our data suggests that peruvioses A and B can be safely employed to treat inflammatory diseases. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  20. Gastro-protective and Anti-stress Efficacies of Monomethyl Fumarate and a Fumaria indica Extract in Chronically Stressed Rats.

    PubMed

    Shakya, Anshul; Soni, Upendra Kumar; Rai, Geeta; Chatterjee, Shyam Sunder; Kumar, Vikas

    2016-05-01

    Results of the very first experiments conducted to evaluate therapeutic potentials of a fumarate containing Fumaria indica extract and of fairly low daily oral doses of monomethyl fumarate for prevention of chronic unavoidable foot-shock stress-induced gastric ulcers, and possible involvement of diverse neuro-hormonal and oxidative process in their stress response desensitizing effects are reported and discussed in this article. Preventive effects of 21 daily oral 60, 120, and 240 mg/kg doses of a standardized 50 % methanolic F. indica extract (MFI) and 1.25, 2.50, and 5.00 mg/kg/day of pure monomethyl fumarate (MMF) were compared in rats subjected to one hour daily unavoidable foot-shocks. A pharmaceutically well-standardized Withania somnifera (WS) root extract was used as a reference herbal anti-stress agent in all experiments. Effects of the treatments on stress-induced alterations in body weight, adrenal and spleen weights, gastric ulcer and ulcer index, weight of glandular stomach, protective mucosal glycoprotein content, cellular proliferation, oxidative stress on stomach fundus, and brain tissues of male rats were quantified. Other parameters quantified were plasma corticosterone levels, brain monoamine levels, and expressions of the cytokines TNF-α, IL-10, and IL-1β in blood and brain of stressed and treated rats. Most but not every observed stress-induced anomalies were suppressed or completely prevented by both MFI and pure MMF treatments in dose-dependent manner. Qualitatively, the observed activity profiles of both of them were similar to those of WS dose tested. These results reveal that both MFI and MMF are potent gastro-protective agents against chronic unavoidable stress-induced ulcers and strongly suggest that they act as regulators or modulators of monoamine, corticosterone, and cytokine homeostasis.

  1. Novel Measure of Opioid Dose and Costs of Care for Diabetes Mellitus: Opioid Dose and Health Care Costs.

    PubMed

    Gautam, Santosh; Franzini, Luisa; Mikhail, Osama I; Chan, Wenyaw; Turner, Barbara J

    2016-03-01

    Diabetes mellitus (DM) has well known costly complications but we hypothesized that costs of care for chronic pain treated with opioid analgesic (OA) medications would also be substantial. In a statewide, privately insured cohort of 29,033 adults aged 18 to 64 years with DM and noncancer pain who filled OA prescription(s) from 2008 to 2012, our outcomes were costs for specific health care services and total costs per 6-month intervals after the first filled OA prescription. Average daily OA dose (4 categories) and total dose (quartiles) in morphine-equivalent milligrams were calculated per 6-month interval after the first OA prescription and combined into a novel OA dose measure. Associations of OA measures with costs of care (n = 126,854 6-month intervals) were examined using generalized estimating equations adjusted for clinical conditions, psychotherapeutic drugs, and DM treatment. Incremental costs for each type of health care service and total cost of care increased progressively with average daily and total OA dose versus no OAs. The combined OA measure identified the highest incremental total costs per 6-month interval that were increased by $8,389 for 50- to 99-mg average daily dose plus >900 mg total dose and, by $9,181 and $9,958 respectively, for ≥100 mg average daily dose plus 301- to 900-mg or >900 mg total dose. In this statewide DM cohort, total health care costs per 6-month interval increased progressively with higher average daily OA dose and with total OA dose but the greatest increases of >$8,000 were distinguished by combinations of higher average daily and total OA doses. The higher costs of care for opioid-treated patients appeared for all types of services and likely reflects multiple factors including morbidity from the underlying cause of pain, care and complications related to opioid use, and poorer control of diabetes as found in other studies. Copyright © 2016 American Pain Society. Published by Elsevier Inc. All rights reserved.

  2. Radiation Doses from the Norwegian Diet.

    PubMed

    Komperød, Mari; Skuterud, Lavrans

    2018-06-13

    Ingestion doses between and within countries are expected to vary significantly due to differences in dietary habits and geographical variations in radionuclide concentrations. This paper presents the most comprehensive assessment to date of the effective radiation dose from the Norwegian diet, from natural as well as anthropogenic radionuclides. Ingestion doses to the Norwegian public are calculated using national dietary statistics and the most relevant radionuclide concentration data for the various food products. The age-weighted average effective dose received by the Norwegian population from the diet is estimated at 0.41 mSv y from naturally occurring radionuclides and 0.010 mSv y from anthropogenic radionuclides. This is approximately 50% higher than the estimated world average. Fish and shellfish is the food group that provides the largest dose contribution from the average Norwegian diet. Although the average dose from anthropogenic radionuclides today is low, the exposure may still be significant for certain critical groups-especially persons who consume large amounts of reindeer meat from the regions that received significant radioactive fallout after the Chernobyl accident. Furthermore, persons with high Rn concentrations in their drinking water are among those receiving the highest ingestion doses in Norway.

  3. Long-term mesalamine maintenance in ulcerative colitis: which is more important? Adherence or daily dose.

    PubMed

    Khan, Nabeel; Abbas, Ali M; Koleva, Yordanka N; Bazzano, Lydia A

    2013-05-01

    There are limited data about the long-term follow-up of patients with ulcerative colitis (UC) maintained on high versus low doses of mesalamine. We evaluated the best long-term average daily dose that would keep the disease in remission. Nationwide ulcerative colitis data were obtained from the Veterans Affairs health care system for the period 2001 to 2011. Those who started mesalamine maintenance during this period were included. Average daily dose and the level of adherence were assessed for the period between the first mesalamine dispense and the date of first flare defined as the first filling of 40 mg/day or more of oral prednisone or any dose of intravenous steroids. Patients with ulcerative colitis maintained on an average daily dose 2.4 to 2.8 g/day (low dose) were compared with 4.4 to 4.8 g/day (high dose). Adherence was assessed using continuous single interval medication availability indicator. We included 4452 patients with a median follow-up of 6 years. There was no significant reduction in the risk of flares when comparing high versus low average mesalamine dose among patients with high [hazard ratio = 0.96, P = 0.8)] and medium (hazard ratio = 0.74, P = 0.17) adherence. However, there was a significant reduction in the risk of flares with high dose of mesalamine among patients with low adherence (hazard ratio = 0.28, P = 0.003). Our data show that when starting a patient on mesalamine, there is no difference in the long-term flare risk between low versus high average daily dose as long as the patients have a high to moderate level of adherence.

  4. Assessment of the effects of CT dose in averaged x-ray CT images of a dose-sensitive polymer gel

    NASA Astrophysics Data System (ADS)

    Kairn, T.; Kakakhel, M. B.; Johnston, H.; Jirasek, A.; Trapp, J. V.

    2015-01-01

    The signal-to-noise ratio achievable in x-ray computed tomography (CT) images of polymer gels can be increased by averaging over multiple scans of each sample. However, repeated scanning delivers a small additional dose to the gel which may compromise the accuracy of the dose measurement. In this study, a NIPAM-based polymer gel was irradiated and then CT scanned 25 times, with the resulting data used to derive an averaged image and a "zero-scan" image of the gel. Comparison between these two results and the first scan of the gel showed that the averaged and zero-scan images provided better contrast, higher contrast-to- noise and higher signal-to-noise than the initial scan. The pixel values (Hounsfield units, HU) in the averaged image were not noticeably elevated, compared to the zero-scan result and the gradients used in the linear extrapolation of the zero-scan images were small and symmetrically distributed around zero. These results indicate that the averaged image was not artificially lightened by the small, additional dose delivered during CT scanning. This work demonstrates the broader usefulness of the zero-scan method as a means to verify the dosimetric accuracy of gel images derived from averaged x-ray CT data.

  5. SU-F-SPS-03: Direct Measurement of Organ Doses Resulting From Head and Cervical Spine Trauma CT Protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carranza, C; Lipnharski, I; Quails, N

    Purpose: This retrospective study analyzes the exposure history of emergency department (ED) patients undergoing head and cervical spine trauma computed tomography (CT) studies. This study investigated dose levels received by trauma patients and addressed any potential concerns regarding radiation dose issues. Methods: Under proper IRB approval, a cohort of 300 trauma cases of head and cervical spine trauma CT scans received in the ED was studied. The radiological image viewing software of the hospital was used to view patient images and image data. The following parameters were extracted: the imaging history of patients, the reported dose metrics from the scannermore » including the volumetric CT Dose Index (CTDIvol) and Dose Length Product (DLP). A postmortem subject was scanned using the same scan techniques utilized in a standard clinical head and cervical spine trauma CT protocol with 120 kVp and 280 mAs. The CTDIvol was recorded for the subject and the organ doses were measured using optically stimulated luminescent (OSL) dosimeters. Typical organ doses to the brain, thyroid, lens, salivary glands, and skin, based on the cadaver studies, were then calculated and reported for the cohort. Results: The CTDIvol reported by the CT scanner was 25.5 mGy for the postmortem subject. The average CTDIvol from the patient cohort was 34.1 mGy. From these metrics, typical average organ doses in mGy were found to be: Brain (44.57), Thyroid (33.40), Lens (82.45), Salivary Glands (61.29), Skin (47.50). The imaging history of the cohort showed that on average trauma patients received 26.1 scans over a lifetime. Conclusion: The average number of scans received on average by trauma ED patients shows that radiation doses in trauma patients may be a concern. Available dose tracking software would be helpful to track doses in trauma ED patients, highlighting the importance of minimizing unnecessary scans and keeping doses ALARA.« less

  6. Tetrameres (Tetrameres) grusi (Shumakovich, 1946) (Nematoda: Tetrameridae) in Eurasian cranes (Grus grus) in central Iran.

    PubMed

    Mowlavi, G R; Massoud, J; Mobedi, I; Gharagozlou, M J; Rezaian, M; Solaymani-Mohammadi, S

    2006-04-01

    The proventriculi of 11 Eurasian cranes (Grus grus) from central Iran were examined for the existence of parasitic helminths. Preliminary reports suggested that the death of these birds was related to untimely cold weather. Nine proventriculi (82%) were heavily infected by the nematode Tetrameres grusi. Glandular structure of the infected proventriculi was replaced by epithelial atrophy but significant inflammatory reactions were not observed in any of the infected organs. In serious infections, the nematode produced vast structural and functional changes, causing organ dysfunction and glandular necrosis. The coincidence of heavy helminth infection at times of environmental stress may lead to debilitation, wasting, and perhaps mortality in migratory cranes.

  7. Gynecomastia: pathomechanisms and treatment strategies.

    PubMed

    Mathur, R; Braunstein, G D

    1997-01-01

    Gynecomastia is common in adolescents and adults, and reflects an underlying imbalance in hormonal physiology in which there is an increase in estrogen action relative to androgen action at the breast tissue level. Most patients have persistent pubertal gynecomastia or breast glandular enlargement from medications, age-related reduction in testicular function, or idiopathic causes. Gynecomastia must be differentiated from pseudogynecomastia due to increased breast adipose tissue, as well as from breast carcinoma. The evaluation of the causes of gynecomastia can be accomplished through history, physical examination and a few laboratory tests. Painful gynecomastia of recent onset may respond to antiestrogen therapy. Surgical removal is the mainstay for long-standing gynecomastia or glandular enlargement that is unresponsive to medical therapy.

  8. Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x-ray irradiators.

    PubMed

    Belley, Matthew D; Wang, Chu; Nguyen, Giao; Gunasingha, Rathnayaka; Chao, Nelson J; Chen, Benny J; Dewhirst, Mark W; Yoshizumi, Terry T

    2014-03-01

    Accurate dosimetry is essential when irradiating mice to ensure that functional and molecular endpoints are well understood for the radiation dose delivered. Conventional methods of prescribing dose in mice involve the use of a single dose rate measurement and assume a uniform average dose throughout all organs of the entire mouse. Here, the authors report the individual average organ dose values for the irradiation of a 12, 23, and 33 g mouse on a 320 kVp x-ray irradiator and calculate the resulting error from using conventional dose prescription methods. Organ doses were simulated in the Geant4 application for tomographic emission toolkit using the MOBY mouse whole-body phantom. Dosimetry was performed for three beams utilizing filters A (1.65 mm Al), B (2.0 mm Al), and C (0.1 mm Cu + 2.5 mm Al), respectively. In addition, simulated x-ray spectra were validated with physical half-value layer measurements. Average doses in soft-tissue organs were found to vary by as much as 23%-32% depending on the filter. Compared to filters A and B, filter C provided the hardest beam and had the lowest variation in soft-tissue average organ doses across all mouse sizes, with a difference of 23% for the median mouse size of 23 g. This work suggests a new dose prescription method in small animal dosimetry: it presents a departure from the conventional approach of assigninga single dose value for irradiation of mice to a more comprehensive approach of characterizing individual organ doses to minimize the error and uncertainty. In human radiation therapy, clinical treatment planning establishes the target dose as well as the dose distribution, however, this has generally not been done in small animal research. These results suggest that organ dose errors will be minimized by calibrating the dose rates for all filters, and using different dose rates for different organs.

  9. Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x-ray irradiators

    PubMed Central

    Belley, Matthew D.; Wang, Chu; Nguyen, Giao; Gunasingha, Rathnayaka; Chao, Nelson J.; Chen, Benny J.; Dewhirst, Mark W.; Yoshizumi, Terry T.

    2014-01-01

    Purpose: Accurate dosimetry is essential when irradiating mice to ensure that functional and molecular endpoints are well understood for the radiation dose delivered. Conventional methods of prescribing dose in mice involve the use of a single dose rate measurement and assume a uniform average dose throughout all organs of the entire mouse. Here, the authors report the individual average organ dose values for the irradiation of a 12, 23, and 33 g mouse on a 320 kVp x-ray irradiator and calculate the resulting error from using conventional dose prescription methods. Methods: Organ doses were simulated in the Geant4 application for tomographic emission toolkit using the MOBY mouse whole-body phantom. Dosimetry was performed for three beams utilizing filters A (1.65 mm Al), B (2.0 mm Al), and C (0.1 mm Cu + 2.5 mm Al), respectively. In addition, simulated x-ray spectra were validated with physical half-value layer measurements. Results: Average doses in soft-tissue organs were found to vary by as much as 23%–32% depending on the filter. Compared to filters A and B, filter C provided the hardest beam and had the lowest variation in soft-tissue average organ doses across all mouse sizes, with a difference of 23% for the median mouse size of 23 g. Conclusions: This work suggests a new dose prescription method in small animal dosimetry: it presents a departure from the conventional approach of assigning a single dose value for irradiation of mice to a more comprehensive approach of characterizing individual organ doses to minimize the error and uncertainty. In human radiation therapy, clinical treatment planning establishes the target dose as well as the dose distribution, however, this has generally not been done in small animal research. These results suggest that organ dose errors will be minimized by calibrating the dose rates for all filters, and using different dose rates for different organs. PMID:24593746

  10. Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x-ray irradiators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belley, Matthew D.; Wang, Chu; Nguyen, Giao

    2014-03-15

    Purpose: Accurate dosimetry is essential when irradiating mice to ensure that functional and molecular endpoints are well understood for the radiation dose delivered. Conventional methods of prescribing dose in mice involve the use of a single dose rate measurement and assume a uniform average dose throughout all organs of the entire mouse. Here, the authors report the individual average organ dose values for the irradiation of a 12, 23, and 33 g mouse on a 320 kVp x-ray irradiator and calculate the resulting error from using conventional dose prescription methods. Methods: Organ doses were simulated in the Geant4 application formore » tomographic emission toolkit using the MOBY mouse whole-body phantom. Dosimetry was performed for three beams utilizing filters A (1.65 mm Al), B (2.0 mm Al), and C (0.1 mm Cu + 2.5 mm Al), respectively. In addition, simulated x-ray spectra were validated with physical half-value layer measurements. Results: Average doses in soft-tissue organs were found to vary by as much as 23%–32% depending on the filter. Compared to filters A and B, filter C provided the hardest beam and had the lowest variation in soft-tissue average organ doses across all mouse sizes, with a difference of 23% for the median mouse size of 23 g. Conclusions: This work suggests a new dose prescription method in small animal dosimetry: it presents a departure from the conventional approach of assigninga single dose value for irradiation of mice to a more comprehensive approach of characterizing individual organ doses to minimize the error and uncertainty. In human radiation therapy, clinical treatment planning establishes the target dose as well as the dose distribution, however, this has generally not been done in small animal research. These results suggest that organ dose errors will be minimized by calibrating the dose rates for all filters, and using different dose rates for different organs.« less

  11. Glandular differentiation in dedifferentiated chondrosarcoma: molecular evidence of a rare phenomenon.

    PubMed

    Jour, George; Liu, Yajuan; Ricciotti, Robert; Pritchard, Colin; Hoch, Benjamin L

    2015-09-01

    Epithelial glandular differentiation in dedifferentiated chondrosarcoma has not been described. Our patient was a 64-year-old man with a history of prostate cancer status post-radiation and hormonal therapy. On screening bone scan, he was found to have increased uptake in his right femoral shaft. Biopsy revealed intermediate-grade conventional chondrosarcoma. Subsequent femoral resection was remarkable for an intermediate-grade chondrosarcomatous component juxtaposed to an area composed of anastomosing nests and cords of malignant epithelial cells showing nuclear atypia and increased mitotic activity. A fibroblastic-appearing spindle cell population was intimately associated with the epithelial cells. The epithelial cells labeled with 34bE12, AE1/AE3, EMA, and Vimentin (both spindled and epithelial components) while being negative for prostate-specific antigen, prostate specific acid phosphatase, cytokeratin 20, thyroid transcription factor-1, and CDX2. The patient developed local recurrence 9 months after the initial resection but has had no metastatic disease and consistently undetectable prostate-specific antigen levels. Deep parallel sequencing of the dedifferentiated component showed a nonsynonymous mutation at exon 4 of IDH1 gene at codon R132 leading to a substitution of arginine, with serine confirming glandular differentiation in dedifferentiated chondrosarcoma. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Direct Analyses of Secondary Metabolites by Mass Spectrometry Imaging (MSI) from Sunflower (Helianthus annuus L.) Trichomes.

    PubMed

    Brentan Silva, Denise; Aschenbrenner, Anna-Katharina; Lopes, Norberto Peporine; Spring, Otmar

    2017-05-10

    Helianthus annuus (sunflower) displays non-glandular trichomes (NGT), capitate glandular trichomes (CGT), and linear glandular trichomes (LGT), which reveal different chemical compositions and locations in different plant tissues. With matrix-assisted laser desorption/ionization (MALDI) and laser desorption/ionization (LDI) mass spectrometry imaging (MSI) techniques, efficient methods were developed to analyze the tissue distribution of secondary metabolites (flavonoids and sesquiterpenes) and proteins inside of trichomes. Herein, we analyzed sesquiterpene lactones, present in CGT, from leaf transversal sections using the matrix 2,5-dihydroxybenzoic acid (DHB) and α-cyano-4-hydroxycinnamic acid (CHCA) (mixture 1:1) with sodium ions added to increase the ionization in positive ion mode. The results observed for sesquiterpenes and polymethoxylated flavones from LGT were similar. However, upon desiccation, LGT changed their shape in the ionization source, complicating analyses by MSI mainly after matrix application. An alternative method could be applied to LGT regions by employing LDI (without matrix) in negative ion mode. The polymethoxylated flavones were easily ionized by LDI, producing images with higher resolution, but the sesquiterpenes were not observed in spectra. Thus, the application and viability of MALDI imaging for the analyses of protein and secondary metabolites inside trichomes were confirmed, highlighting the importance of optimization parameters.

  13. Microbe-based technology ameliorates glandular trichomes, secondary metabolites and antioxidants in Pelargonium graveolens L'Hér.

    PubMed

    Gupta, Rupali; Singh, Akanksha; Pandey, Rakesh

    2016-09-01

    Despite the vast exploration of microbes for plant health, there is a lack of knowledge about the synergistic effects of specific microorganisms in sustainable agriculture, especially in medicinal plants such as Pelargonium graveolens L'Hér. The aim of this study was to evaluate how synergistic microbes Trichoderma harzianum ThU, Glomus intraradices and Bacillus subtilis CIM affected crop productivity, secondary metabolites and glandular trichome number in P. graveolens. The results demonstrated a significant (P < 0.05) increase in plant growth, secondary metabolites, total chlorophyll, carotenoids, carbohydrates, total phenolics, total flavonoids, free radical-scavenging activity and total antioxidant capacity of P. graveolens treated with synergistic bioinoculants as compared with the control. Most interestingly, an increase in essential oil by 32% in the treatment with all three microbes was observed. Furthermore, the principal aroma compounds citronellol and geraniol also increased in the same treatment. A positive and direct correlation was observed between essential oil content and number of glandular trichomes in all treatments. The present study highlights an explicit amalgamation of prospective microbes showing potential for synergism that act as biostimulants in enhancing plant production and improving the antioxidant and aroma profile of P. graveolens. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  14. Morphology and Histochemistry of the Glandular Trichomes of Lippia scaberrima (Verbenaceae)

    PubMed Central

    Combrinck, S.; Du Plooy, G. W.; McCrindle, R. I.; Botha, B. M.

    2007-01-01

    Background and Aims Lippia scaberrima, an aromatic indigenous South African plant, with medicinal application, potentially has economic value. The production of essential oil from this plant has not been optimized, and this study of the chemico-morphological characteristics was aimed at determining the location of oil production within the plant. Furthermore, the locality of other secondary metabolites important in medicinal applications needed to be ascertained. This information would be useful in deciding the protocol required for isolation of such compounds. Methods The morphology of the glandular trichomes was investigated using a combination of scanning electron and light microscopy. Concurrently, the chemical content was studied by applying various chemical reagents and fluorescence microscopy. Key Results Three types of trichomes were distinguished on the material investigated. Large, bulbous peltate glands containing compounds of terpenoid nature are probably the main site of essential oil accumulation. Small glands were found to be both peltate and capitate and fluorescent stain indicated the possible presence of phenolic compounds. The third type was a slender tapered seta with an ornamented surface and uniseriate base, and evidently secretory in nature. Conclusions This study linking the chemical content and morphology of the glandular trichomes of L. scaberrima has contributed to the knowledge and understanding of secretory structures of Lippia spp. in general. PMID:17468110

  15. Effect of Excess Iodide Intake on Salivary Glands in a Swiss Albino Mice Model

    PubMed Central

    Ross, Gloria Romina; Fabersani, Emanuel; Russo, Matías; Gómez, Alba; Japaze, Hugo; González, Silvia Nelina

    2017-01-01

    Iodine is an important micronutrient required for nutrition. Excess iodine has adverse effects on thyroid, but there is not enough information regarding its effect on salivary glands. In addition to food and iodized salt, skin disinfectants and maternal nutritional supplements contain iodide, so its intake could be excessive during pregnancy, lactation, and infancy. The aim of this work was to evaluate the effect of excess iodide ingestion on salivary glands during mating, gestation, lactation, and postweaning period in mouse. During assay, mice were allocated into groups: control and treatment groups (received distilled water with NaI 1 mg/mL). Water intake, glandular weight, and histology were analyzed. Treatment groups showed an increase in glandular weight and a significantly (p < 0.05) higher water intake than control groups. Lymphocyte infiltration was observed in animals of treatment groups, while there was no infiltration in glandular sections of control groups. Results demonstrated that a negative relationship could exist between iodide excess and salivary glands. This work is novel evidence that high levels of iodide intake could induce mononuclear infiltration in salivary glands. These results should be considered, especially in pregnant/lactating women, to whom a higher iodine intake is usually recommended. PMID:29250546

  16. Prostate cancer diagnosis with fluorescence lifetime imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Sridharan, Shamira; Gandour-Edwards, Regina F.; Dall'Era, Marc; Marcu, Laura

    2017-02-01

    More than 1 million men in the United States undergo a prostate biopsy procedure annually and approximately 200,000 men receive a diagnosis of prostate cancer. 5-10% of these men have to undergo a repeat biopsy due to insufficient tissue sampling. We are studying the utility of a multi-spectral time resolved fluorescence spectroscopy (MS-TRFS) technique for real-time prostate cancer diagnosis. The MS-TRFS imaging setup, which includes a fiberoptic set-up with a 355nm excitation light source coupled with a blue (450nm) aiming beam, was used to image ex-vivo prostatectomy specimen. The prostate tissue from 11 patients was sectioned at 2mm thickness and the fluorescence lifetime information was overlaid spatially for histology and thus, diagnostic co-registration. Initial results show that fluorescence lifetime in the 390±40nm channel, which measures collagen and elastin signatures, is longer for glandular regions than in the stromal regions. Additionally, lifetime in the 452±45nm channel, corresponding to NAD redox state, is longer in the cancerous glandular region in comparison with the normal glandular regions. Current work is focused on developing real-time quantitative algorithms to combine the fluorescence signatures from the two channels for performing prostate cancer diagnosis on biopsies.

  17. The effect of sampling methods on the apparent constituents of ink from the squid Sepioteuthis australis.

    PubMed

    Madaras, F; Gerber, J P; Peddie, F; Kokkinn, M J

    2010-11-01

    Results of experiments conducted on ink recovered from the squid Sepioteuthis australis indicate that there is no epinephrine or protein naturally present in the ink as it would be ejected in vivo. Protein content was effectively zero when ink was syringed from the duct end of the ink sac of freshly killed animals. By contrast, there were proteins in samples collected from dead specimens where ink was collected by a stripping method. From these samples, a single large molecular weight protein was identified as having tyrosinase activity. Digestion of syringed ink did not yield signs of melanin-bound proteins. Analysis of supernatants after centrifugation of squid ink consistently revealed the presence of DOPA, dopamine, and taurine, whereas epinephrine and nor-epinephrine were recorded from what was believed to be contaminated ink. Histological investigations of the ink sac revealed a compartmentalised glandular structure distal to the duct end. Closer observation of the glandular tissue showed that compartments increased in size as they matured and moved further into the lumen. It was concluded that the presence of epinephrine and tyrosinase (or a related protein) in the ink of S. australis could be attributed to rupturing of basal glandular compartments or contamination from other sources during the extraction process.

  18. Benign intestinal glandular lesions in the vagina: a possible correlation with implantation.

    PubMed

    Lu, Weiwei; Zhang, Xiaofei; Lu, Bingjian

    2016-06-17

    Enteric-type glandular lesions are extremely rare in the vagina. Their histological origin remains a matter of speculation at present. We review two rectal mucosal prolapse-like polyps and one intestinal-type adenosis in the vagina. Case 1, a 64-year-old woman, presented with a vaginal polypoid lesion with a size of 4 × 3 × 3 cm. Case 2, an 8-year-old girl, had a 1.5 × 1.5 × 0.8-cm pedunculated polyp in the vaginal navicular fossa and a clinically suspected rectovaginal fistula. Case 1 and 3 had an obsolete severe perineal laceration. On histopathological examination, cases 1 and 2 resembled rectal mucosal prolapse or inflammatory cloacogenic polyp (rectal mucosal prolapse-like polyp). Case 3 had an incidental intestinal-type adenosis in the removed vaginal wall. Immunohistochemistry confirmed the intestinal differentiation in all 3 lesions by showing diffuse CDX2-positive, CK20-positive, and scattered chromogranin A-positive neuroendocrinal cells in the lower compartment of the crypt. In summary, we report herein three unusual cases of benign intestinal-type glandular lesions in the vagina including two rectal mucosal prolapse-like polyps and one case of intestinal-type adenosis, and discuss possibilities for their histogenetic basis.

  19. [Partial regression of Barret esophagus with high grade dysplasia and adenocarcinoma after photocoagulation and endocurietherapy under antisecretory treatment].

    PubMed

    Fremond, L; Bouché, O; Diébold, M D; Demange, L; Zeitoun, P; Thiefin, G

    1995-01-01

    Barrett's oesophagus is a premalignant condition. The possibility of eradicating at least partially the metaplastic epithelium has been reported recently. In this case report, a patient with Barrett's oesophagus complicated by high grade dysplasia and focal adenocarcinoma was treated by Nd:Yag laser then high dose rate intraluminal irradiation while on omeprazole 40 mg/day. A partial eradication of Barrett's oesophagus and a transient tumoural regression were obtained. Histologically, residual specialized-type glandular tissue was observed beneath regenerative squamous epithelium. Four months after intraluminal irradiation, a local tumoural recurrence was detected while the area of restored squamous epithelium was unchanged on omeprazole 40 mg/day. This indicates that physical destruction of Barrett's oesophagus associated with potent antisecretory treatment can induce a regression of the metaplastic epithelium, even in presence of high grade dysplasia. The persistence of specialized-type glands beneath the squamous epithelium raises important issues about its potential malignant degeneration.

  20. Induction of UO-44 gene expression by tamoxifen in the rat uterus and ovary.

    PubMed

    Huynh, H; Ng, C Y; Lim, K B; Ong, C K; Ong, C S; Tran, E; Tuyen Nguyen, T T; Chan, T W

    2001-07-01

    A complementary DNA, uterine-ovarian-specific gene 44 (UO-44), has been isolated from tamoxifen-induced rat uterine complementary DNA library using differential display techniques. UO-44 transcripts are found to be abundant in the uterus and ovary. UO-44 gene expression in the uterus is strictly regulated by estrogens, tamoxifen, and GH, whereas the pure antiestrogen ICI 182780 is inhibitory. Treatment of ovariectomized rats and hypophysectomized rats with tamoxifen and GH, respectively, resulted in up-regulation of UO-44 expression in a dose-dependent manner. In situ hybridization revealed that UO-44 gene expression was restricted to the luminal and glandular epithelial cells of the uterus and to granulosa cells of medium-size ovarian follicles. Transfection studies showed that UO-44 was a membrane-associated protein. Because estrogens, tamoxifen, and GH are stimulators of uterine luminal epithelial cell growth in vivo, UO-44 protein may serve as a mediator of the effect of these compounds in inducing epithelial proliferation and differentiation in these tissues.

  1. Low-contrast lesion detection in tomosynthetic breast imaging using a realistic breast phantom

    NASA Astrophysics Data System (ADS)

    Zhou, Lili; Oldan, Jorge; Fisher, Paul; Gindi, Gene

    2006-03-01

    Tomosynthesis mammography is a potentially valuable technique for detection of breast cancer. In this simulation study, we investigate the efficacy of three different tomographic reconstruction methods, EM, SART and Backprojection, in the context of an especially difficult mammographic detection task. The task is the detection of a very low-contrast mass embedded in very dense fibro-glandular tissue - a clinically useful task for which tomosynthesis may be well suited. The project uses an anatomically realistic 3D digital breast phantom whose normal anatomic variability limits lesion conspicuity. In order to capture anatomical object variability, we generate an ensemble of phantoms, each of which comprises random instances of various breast structures. We construct medium-sized 3D breast phantoms which model random instances of ductal structures, fibrous connective tissue, Cooper's ligaments and power law structural noise for small scale object variability. Random instances of 7-8 mm irregular masses are generated by a 3D random walk algorithm and placed in very dense fibro-glandular tissue. Several other components of the breast phantom are held fixed, i.e. not randomly generated. These include the fixed breast shape and size, nipple structure, fixed lesion location, and a pectoralis muscle. We collect low-dose data using an isocentric tomosynthetic geometry at 11 angles over 50 degrees and add Poisson noise. The data is reconstructed using the three algorithms. Reconstructed slices through the center of the lesion are presented to human observers in a 2AFC (two-alternative-forced-choice) test that measures detectability by computing AUC (area under the ROC curve). The data collected in each simulation includes two sources of variability, that due to the anatomical variability of the phantom and that due to the Poisson data noise. We found that for this difficult task that the AUC value for EM (0.89) was greater than that for SART (0.83) and Backprojection (0.66).

  2. Interstitial photodynamic therapy of canine prostate with meso-tetra-(m-hydroxyphenyl) chlorin and 5-aminolevulinic acid: a preliminary study

    NASA Astrophysics Data System (ADS)

    Chang, Shi-Chung; Buonaccorsi, Giovanni A.; MacRobert, Alexander J.; Bown, Stephen G.

    1996-01-01

    Photodynamic therapy (PDT) is proved to have potential for managing various malignancies. We investigated tissue biodistribution and photodynamic effects on a canine model in vivo using second generation photosensitizers, meso-tetra(m-hydroxyphenyl)chlorin (mTHPC) and 5-aminolaevulinic acid (ALA) to evaluate the feasibility and possible future application of PDT on the prostate. Using fluorescence microscopy, the optimal sensitization time of the prostate was between 24 - 72 hours with mTHPC and, 3 hours with ALA. After optimum time of sensitization, prostates of mature beagle were treated with laser at various sites by placing fiber interstitially under the guidance of transrectal ultrasound. The light dose for each treatment site was 100 J (100 mW for 1,000 seconds at the wavelength of 650 and 630 nm, respectively). With mTHPC, single laser fiber was able to induce organ confined PDT lesion as large as 20 by 18 by 18 mm in size. However, the PDT lesion with ALA was negligible 3 days after treatment. Physical distress manifested as urinary retention, poor appetite and body weigh loss, was more prominent with increasing number of treatment sites as a result of extensive prostatic swelling and urethral damages. However, these problems usually alleviated spontaneously 7 to 10 days after PDT. The characteristic histological changes were hemorrhagic necrosis and glandular destruction with preservation of interlobular collagen fibers. Urethral damage seen at the early stage healed by regeneration of urothelium in 4 weeks. We conclude that interstitial PDT with mTHPC is technically possible to produce extensive glandular necrosis in the normal prostate which heals safely and does not change the prostatic architecture. ALA, although it seems promising for bladder tumors, is much less effective than mTHPC on the prostate. With mTHPC, it might have the potential for treating prostate cancers localized in the periphery of the gland.

  3. Endocytoscopic findings of lymphomas of the stomach.

    PubMed

    Isomoto, Hajime; Matsushima, Kayoko; Hayashi, Tomayoshi; Imaizumi, Yoshitaka; Shiota, Junya; Ishii, Hiroyuki; Minami, Hitomi; Ohnita, Ken; Takeshima, Fuminao; Shikuwa, Saburo; Miyazaki, Yasushi; Nakao, Kazuhiko

    2013-12-26

    The gastric lesions of various lymphomas were observed at the cellular level using endocytoscopy. Endocytoscopy and magnifying endoscopy with narrow band imaging (NBI) were performed in 17 patients with lymphomas of the stomach. The lesions consisted of 7 with low-grade mucosa-associated lymphoid tissue (MALT), 5 with gastric involvement by adult T-cell leukemia/lymphoma (ATLL), 4 with diffuse large B-cell lymphoma (DLBCL), and 1 with peripheral T-cell lymphoma. On conventional endoscopy, 9 were classified as having superficial spreading type, 7 were mass-forming type, and 1 was diffuse infiltrating type. Anti-H. pylori treatment was given in the 7 MALT lymphoma cases. NBI magnification endoscopy invariably showed dilatation or ballooning and destruction of gastric pits and elongation and distortion in microvessels. Endocytoscopy showed mucosal aggregation of interstitial cellular elements in almost all gastric lymphoma cases. The nuclear diversity in size and configuration was exclusively seen in gastric lymphomas other than MALT lymphoma, whereas the nuclei of MALT lymphoma cells were regular and small to moderate in size. Inter-glandular infiltration by lymphomatous cell elements was frequently observed in MALT lymphoma and DLBCL, but it was uncommon in peripheral gastric T-cell malignancies. Endocytoscopy could identify the disease-specific histology, the lymphoepithelial origin, as inter-glandular infiltration of cellular components in MALT lymphoma and the possibly related DLBCL cases. Complete regression (CR) was observed in 2 of the 7 MALT lymphoma patients. In the 2 patients with CR who underwent repeat endocytoscopy, the ultra-high magnification abnormalities returned to normal, while they were unchanged in those without tumor regression. On endocytoscopy, intra-glandular aggregation of cellular components was invariably identified in lymphomas of the stomach. Nuclear regularity in size and configuration may indicate the cytological grade, differentiating the indolent low-grade from aggressive lymphoproliferative diseases. The inter-glandular infiltration seen on endocytoscopy can indicate the lymphoepithelial lesions seen in MALT lymphoma and related DLBCL. Endocytoscopy would be applicable for virtual histopathological diagnosis of different lymphoproliferative disorders and their clinical assessment during ongoing endoscopy.

  4. Insulin-like growth factor (IGF)-I controls prostate fibromuscular development: IGF-I inhibition prevents both fibromuscular and glandular development in eugonadal mice.

    PubMed

    Kleinberg, David L; Ruan, Weifeng; Yee, Douglas; Kovacs, Kalman T; Vidal, Sergio

    2007-03-01

    Although antiandrogen therapy has been shown effective in treating prostatic tumors, it is relatively ineffective in treating benign prostatic hyperplasia (BPH). In an attempt to understand better the role of androgens in the development of the normal prostate and BPH, we studied the relative effects of testosterone and IGF-I on the development of the two compartments of the prostate in castrated IGF-I((-/-)) male mice. Here we report that IGF-I stimulated the development of the fibromuscular compartment, but testosterone inhibited it (stromal epithelial ratio 2.17 vs. 0.83, respectively; P < 0.001). Testosterone also impaired IGF-I induced insulin receptor substrate-1 phosphorylation and cell division, and increased apoptosis in fibromuscular tissue. In sharp contrast IGF-I and testosterone both stimulated the development of the glandular compartment individually and together. The combined effects were either additive or synergistic on compartment size, cell division, insulin receptor substrate-1 phosphorylation, and probasin production. Together they also had a greater inhibitory effect on apoptosis in gland tissue. To determine whether IGF-I inhibition would inhibit both fibromuscular and glandular compartments, we tested the effect of IGF binding protein-1 on prostate development in two different models: castrated Ames dwarf mice and eugonadal normal male mice. IGF binding protein-1 blocked bovine GH-induced fibromuscular and glandular development in both. It also inhibited epithelial cell division and increased apoptosis in both prostate compartments in the eugonadal mice. The observed discordance between IGF-I and testosterone control of prostate compartment development might explain the relative failure of 5alpha-reductase inhibition in BPH and why testosterone inhibition might theoretically reduce gland volume but increase fibromuscular tissue. The work also provides a rationale for considering IGF-I inhibition as therapy for BPH to reduce the size of both prostate compartments.

  5. A role for G-protein coupled estrogen receptor (GPER) in estrogen-induced carcinogenesis: Dysregulated glandular homeostasis, survival and metastasis.

    PubMed

    Filardo, Edward J

    2018-02-01

    Mechanisms of carcinogenesis by estrogen center on its mitogenic and genotoxic potential on tumor target cells. These models suggest that estrogen receptor (ER) signaling promotes expansion of the transformed population and that subsequent accumulation of somatic mutations that drive cancer progression occur via metabolic activation of cathecol estrogens or by epigenetic mechanisms. Recent findings that GPER is linked to obesity, vascular pathology and immunosuppression, key events in the development of metabolic syndrome and intra-tissular estrogen synthesis, provides an alternate view of estrogen-induced carcinogenesis. Consistent with this concept, GPER is directly associated with clinicopathological indices that predict cancer progression and poor survival in breast and gynecological cancers. Moreover, GPER manifests cell biological responses and a microenvironment conducive for tumor development and cancer progression, regulating cellular responses associated with glandular homeostasis and survival, invading surrounding tissue and attracting a vascular supply. Thus, the cellular actions attributed to GPER fit well with the known molecular mechanisms of G-protein coupled receptors, GPCRs, namely, their ability to transactivate integrins and EGF receptors and alter the interaction between glandular epithelia and their extracellular environment, affecting epithelial-to-mesenchymal transition (EMT) and allowing for tumor cell survival and dissemination. This perspective reviews the molecular and cellular responses manifested by GPER and evaluates its contribution to female reproductive cancers as diseases that progress as a result of dysregulated glandular homeostasis resulting in chronic inflammation and metastasis. This review is organized in sections as follows: I) a brief synopsis of the current state of knowledge regarding estrogen-induced carcinogenesis, II) a review of evidence from clinical and animal-based studies that support a role for GPER in cancer progression, and III) a mechanistic framework describing how GPER-mediated estrogen action may influence the tumor and its microenvironment. Published by Elsevier Ltd.

  6. Evaluation of Glandular Liposculpture as a Single Treatment for Grades I and II Gynaecomastia.

    PubMed

    Abdelrahman, Islam; Steinvall, Ingrid; Mossaad, Bassem; Sjoberg, Folke; Elmasry, Moustafa

    2018-03-16

    Gynaecomastia is a benign enlargement of the male breast, of which the psychological burden on the patient can be considerable, with the increased risk of disorders such as depression, anxiety, and social phobia. Minimal scarring can be achieved by liposuction alone, though it is known to have a limited effect on the dense glandular and fibroconnective tissues. We know of few studies published on "liposuction alone", so we designed this study to evaluate the outcome of combining liposuction with glandular liposculpturing through two axillary incisions as a single treatment for the management of grades I and II gynaecomastia. We made a retrospective analysis of 18 patients with grade I or II gynaecomastia who were operated on by combined liposuction and glandular liposculpturing using a fat disruptor cannula, without glandular excision, during the period 2014-2016. Patient satisfaction was assessed using the Breast Evaluation Questionnaire (BEQ), which is a 5-point Likert scale (1 = very dissatisfied; 2 = dissatisfied; 3 = neither; 4 = satisfied; 5 = very satisfied). The post-operative aesthetic appearance of the chest was evaluated by five independent observers on a scale from 1 to 5 (5 = considerable improvement). The patient mean (SD) overall satisfaction score was 4.7 (0.7), in which 92% of the responders were "satisfied" to "very satisfied". The mean (SD) BEQ for all questions answered increased from 2.1 (0.2) "dissatisfied" preoperatively to 4.1 (0.2) "satisfied" post-operatively. The observers' mean (SD) rate for the improvement in the shape of the front chest wall was 4.1 (0.7). No haematomas were recorded, one patient developed a wound infection, and two patients complained of remnants of tissue. The median (IQR) body mass index was 27.4 (26.7-29.4), 11 patients had gynaecomastia grade I, and 7 patients grade II. The median (IQR) volume of aspirated fat was 700 ml (650-800), operating time was 67 (65-75) minutes, 14 patients had general anaesthesia, and hospital charges were US$ 538 (481-594). Combined liposuction and liposculpturing using the fat disruptor cannula resulted in satisfied patients and acceptable outcomes according to the observers' ratings. It could be a useful alternative with an outcome that corresponds to that of more expensive methods. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  7. Plan averaging for multicriteria navigation of sliding window IMRT and VMAT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Craft, David, E-mail: dcraft@partners.org; Papp, Dávid; Unkelbach, Jan

    2014-02-15

    Purpose: To describe a method for combining sliding window plans [intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT)] for use in treatment plan averaging, which is needed for Pareto surface navigation based multicriteria treatment planning. Methods: The authors show that by taking an appropriately defined average of leaf trajectories of sliding window plans, the authors obtain a sliding window plan whose fluence map is the exact average of the fluence maps corresponding to the initial plans. In the case of static-beam IMRT, this also implies that the dose distribution of the averaged plan is the exact dosimetricmore » average of the initial plans. In VMAT delivery, the dose distribution of the averaged plan is a close approximation of the dosimetric average of the initial plans. Results: The authors demonstrate the method on three Pareto optimal VMAT plans created for a demanding paraspinal case, where the tumor surrounds the spinal cord. The results show that the leaf averaged plans yield dose distributions that approximate the dosimetric averages of the precomputed Pareto optimal plans well. Conclusions: The proposed method enables the navigation of deliverable Pareto optimal plans directly, i.e., interactive multicriteria exploration of deliverable sliding window IMRT and VMAT plans, eliminating the need for a sequencing step after navigation and hence the dose degradation that is caused by such a sequencing step.« less

  8. Necrosis of the femoral head after kidney transplantation.

    PubMed

    Lausten, G S; Lemser, T; Jensen, P K; Egfjord, M

    1998-12-01

    We reviewed the medical records of 750 patients (445 men, 305 women), who had received a kidney transplant during the period 1968-1995, for any sign of necrosis of the femoral head. For post-operative immunosuppression, 374 patients had received high-dose corticosteroids (average 12.5 g during the first year post-operatively), while 376 patients had received low-dose corticosteroids (average 6.5 g during the first year post-operatively) and cyclosporin A. Survival curves according to Kaplan and Meier (J Am Stat Ass 1958: 53: 457-481) were constructed. In the high-dose steroid group, 42/374 patients (11.2%) developed femoral head necrosis, at an average of 26.2 months post-transplantation. In the low-dose steroid group, only 19/376 (5.1%) patients developed this complication, at an average of 20.5 months post-transplantation. This difference in numbers of femoral head necroses was highly significant (p < 0.005). We conclude that steroid doses should be minimized whenever feasible in post-transplant immunosuppression therapy.

  9. A bone marrow toxicity model for 223Ra alpha-emitter radiopharmaceutical therapy

    NASA Astrophysics Data System (ADS)

    Hobbs, Robert F.; Song, Hong; Watchman, Christopher J.; Bolch, Wesley E.; Aksnes, Anne-Kirsti; Ramdahl, Thomas; Flux, Glenn D.; Sgouros, George

    2012-05-01

    Ra-223, an α-particle emitting bone-seeking radionuclide, has recently been used in clinical trials for osseous metastases of prostate cancer. We investigated the relationship between absorbed fraction-based red marrow dosimetry and cell level-dosimetry using a model that accounts for the expected localization of this agent relative to marrow cavity architecture. We show that cell level-based dosimetry is essential to understanding potential marrow toxicity. The GEANT4 software package was used to create simple spheres representing marrow cavities. Ra-223 was positioned on the trabecular bone surface or in the endosteal layer and simulated for decay, along with the descendants. The interior of the sphere was divided into cell-size voxels and the energy was collected in each voxel and interpreted as dose cell histograms. The average absorbed dose values and absorbed fractions were also calculated in order to compare those results with previously published values. The absorbed dose was predominantly deposited near the trabecular surface. The dose cell histogram results were used to plot the percentage of cells that received a potentially toxic absorbed dose (2 or 4 Gy) as a function of the average absorbed dose over the marrow cavity. The results show (1) a heterogeneous distribution of cellular absorbed dose, strongly dependent on the position of the cell within the marrow cavity; and (2) that increasing the average marrow cavity absorbed dose, or equivalently, increasing the administered activity resulted in only a small increase in potential marrow toxicity (i.e. the number of cells receiving more than 4 or 2 Gy), for a range of average marrow cavity absorbed doses from 1 to 20 Gy. The results from the trabecular model differ markedly from a standard absorbed fraction method while presenting comparable average dose values. These suggest that increasing the amount of radioactivity may not substantially increase the risk of toxicity, a result unavailable to the absorbed fraction method of dose calculation.

  10. The key role of peltate glandular trichomes in symbiota comprising clavicipitaceous fungi of the genus periglandula and their host plants.

    PubMed

    Steiner, Ulrike; Kucht, Sabine Hellwig neé; Ahimsa-Müller, Mahalia A; Grundmann, Nicola; Li, Shu-Ming; Drewke, Christel; Leistner, Eckhard

    2015-04-16

    Clavicipitaceous fungi producing ergot alkaloids were recently discovered to be epibiotically associated with peltate glandular trichomes of Ipomoea asarifolia and Turbina corymbosa, dicotyledonous plants of the family Convolvulaceae. Mediators of the close association between fungi and trichomes may be sesquiterpenes, main components in the volatile oil of different convolvulaceous plants. Molecular biological studies and microscopic investigations led to the observation that the trichomes do not only secrete sesquiterpenes and palmitic acid but also seem to absorb ergot alkaloids from the epibiotic fungal species of the genus Periglandula. Thus, the trichomes are likely to have a dual and key function in a metabolic dialogue between fungus and host plant.

  11. Human immunodeficiency virus endocrinopathy

    PubMed Central

    Sinha, Uma; Sengupta, Nilanjan; Mukhopadhyay, Prasanta; Roy, Keshab Sinha

    2011-01-01

    Human immunodeficiency virus (HIV) endocrinopathy encompasses a broad spectrum of disorders. Almost all the endocrine organs are virtually affected by HIV infection. HIV can directly alter glandular function. More commonly secondary endocrine dysfunction occurs due to opportunistic infections and neoplasms in immunocompromised state. The complex interaction between HIV infection and endocrine system may be manifested as subtle biochemical and hormonal perturbation to overt glandular failure. Antiretroviral therapy as well as other essential medications often result in adverse endocrinal consequences. Apart from adrenal insufficiency, hypogonadism, diabetes and bone loss, AIDS wasting syndrome and HIV lipodystrophy need special reference. Endocrinal evaluation should proceed as in other patients with suspected endocrine dysfunction. Available treatment options have been shown to improve quality of life and long-term mortality in AIDS patients. PMID:22028995

  12. Georgia fishery study: implications for dose calculations. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turcotte, M.D.S.

    Fish consumption will contribute a major portion of the estimated individual and population doses from L-Reactor liquid releases and Cs-137 remobilization in Steel Creek. It is therefore important that the values for fish consumption used in dose calculations be as realistic as possible. Since publication of the L-Reactor Environmental Information Document (EID), data have become available on sport fishing in the Savannah River. These data provide SRP with a site-specific sport fish harvest and consumption values for use in dose calculations. The Georgia fishery data support the total population fish consumption and calculated dose reported in the EID. The datamore » indicate, however, that both the EID average and maximum individual fish consumption have been underestimated, although each to a different degree. The average fish consumption value used in the EID is approximately 3% below the lower limit of the fish consumption range calculated using the Georgia data. Maximum fish consumption in the EID has been underestimated by approximately 60%, and doses to the maximum individual should also be recalculated. Future dose calculations should utilize an average adult fish consumption value of 11.3 kg/yr, and a maximum adult fish consumption value of 34 kg/yr. Consumption values for the teen and child age groups should be increased proportionally: (1) teen average = 8.5; maximum = 25.9 kg/yr; and (2) child average = 3.6; maximum = 11.2 kg/yr. 8 refs.« less

  13. Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: I. A theoretical model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carton, Ann-Katherine; Ullberg, Christer; Lindman, Karin

    2010-11-15

    Purpose: Dual-energy (DE) iodine contrast-enhanced x-ray imaging of the breast has been shown to identify cancers that would otherwise be mammographically occult. In this article, theoretical modeling was performed to obtain optimally enhanced iodine images for a photon-counting digital breast tomosynthesis (DBT) system using a DE acquisition technique. Methods: In the system examined, the breast is scanned with a multislit prepatient collimator aligned with a multidetector camera. Each detector collects a projection image at a unique angle during the scan. Low-energy (LE) and high-energy (HE) projection images are acquired simultaneously in a single scan by covering alternate collimator slits withmore » Sn and Cu filters, respectively. Sn filters ranging from 0.08 to 0.22 mm thickness and Cu filters from 0.11 to 0.27 mm thickness were investigated. A tube voltage of 49 kV was selected. Tomographic images, hereafter referred to as DBT images, were reconstructed using a shift-and-add algorithm. Iodine-enhanced DBT images were acquired by performing a weighted logarithmic subtraction of the HE and LE DBT images. The DE technique was evaluated for 20-80 mm thick breasts. Weighting factors, w{sub t}, that optimally cancel breast tissue were computed. Signal-difference-to-noise ratios (SDNRs) between iodine-enhanced and nonenhanced breast tissue normalized to the square root of the mean glandular dose (MGD) were computed as a function of the fraction of the MGD allocated to the HE images. Peak SDNR/{radical}(MGD) and optimal dose allocations were identified. SDNR/{radical}(MGD) and dose allocations were computed for several practical feasible system configurations (i.e., determined by the number of collimator slits covered by Sn and Cu). A practical system configuration and Sn-Cu filter pair that accounts for the trade-off between SDNR, tube-output, and MGD were selected. Results: w{sub t} depends on the Sn-Cu filter combination used, as well as on the breast thickness; to optimally cancel 0% with 50% glandular breast tissue, w{sub t} values were found to range from 0.46 to 0.72 for all breast thicknesses and Sn-Cu filter pairs studied. The optimal w{sub t} values needed to cancel all possible breast tissue glandularites vary by less than 1% for 20 mm thick breasts and 18% for 80 mm breasts. The system configuration where one collimator slit covered by Sn is alternated with two collimator slits covered by Cu delivers SDNR/{radical}(MGD) nearest to the peak value. A reasonable compromise is a 0.16 mm Sn-0.23 mm Cu filter pair, resulting in SDNR values between 1.64 and 0.61 and MGD between 0.70 and 0.53 mGy for 20-80 mm thick breasts at the maximum tube current. Conclusions: A DE acquisition technique for a photon-counting DBT imaging system has been developed and optimized.« less

  14. Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lesperance, Marielle; Inglis-Whalen, M.; Thomson, R. M., E-mail: rthomson@physics.carleton.ca

    Purpose : To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with{sup 125}I, {sup 103}Pd, or {sup 131}Cs seeds, and to investigate doses to ocular structures. Methods : An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom andmore » our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Results : Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20–30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%–10% and 13%–14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%–17% and 29%–34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model simulation by up to 16%. In the full eye model simulations, the average dose to the lens is larger by 7%–9% than the dose to the center of the lens, and the maximum dose to the optic nerve is 17%–22% higher than the dose to the optic disk for all radionuclides. In general, when normalized to the same prescription dose at the tumor apex, doses delivered to all structures of interest in the full eye model are lowest for{sup 103}Pd and highest for {sup 131}Cs, except for the tumor where the average dose is highest for {sup 103}Pd and lowest for {sup 131}Cs. Conclusions : The eye is not radiologically water-equivalent, as doses from simulations of the plaque in the full eye model differ considerably from doses for the plaque in a water phantom and from simulated TG-43 calculated doses. This demonstrates the importance of model-based dose calculations for eye plaque brachytherapy, for which accurate elemental compositions of ocular media are necessary.« less

  15. Pediatric chest and abdominopelvic CT: organ dose estimation based on 42 patient models.

    PubMed

    Tian, Xiaoyu; Li, Xiang; Segars, W Paul; Paulson, Erik K; Frush, Donald P; Samei, Ehsan

    2014-02-01

    To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. The institutional review board approved this HIPAA-compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0-16 years; weight range, 2-80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDI(vol)). The relationships between CTDI(vol)-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. For organs within the image coverage, CTDI(vol)-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R(2) > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%-32%) mainly because of the effect of overranging. It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDI(vol). These CTDI(vol)-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice. © RSNA, 2013.

  16. Radiation dose rates now and in the future for residents neighboring restricted areas of the Fukushima Daiichi Nuclear Power Plant

    PubMed Central

    Harada, Kouji H.; Niisoe, Tamon; Imanaka, Mie; Takahashi, Tomoyuki; Amako, Katsumi; Fujii, Yukiko; Kanameishi, Masatoshi; Ohse, Kenji; Nakai, Yasumichi; Nishikawa, Tamami; Saito, Yuuichi; Sakamoto, Hiroko; Ueyama, Keiko; Hisaki, Kumiko; Ohara, Eiji; Inoue, Tokiko; Yamamoto, Kanako; Matsuoka, Yukiyo; Ohata, Hitomi; Toshima, Kazue; Okada, Ayumi; Sato, Hitomi; Kuwamori, Toyomi; Tani, Hiroko; Suzuki, Reiko; Kashikura, Mai; Nezu, Michiko; Miyachi, Yoko; Arai, Fusako; Kuwamori, Masanori; Harada, Sumiko; Ohmori, Akira; Ishikawa, Hirohiko; Koizumi, Akio

    2014-01-01

    Radiation dose rates were evaluated in three areas neighboring a restricted area within a 20- to 50-km radius of the Fukushima Daiichi Nuclear Power Plant in August–September 2012 and projected to 2022 and 2062. Study participants wore personal dosimeters measuring external dose equivalents, almost entirely from deposited radionuclides (groundshine). External dose rate equivalents owing to the accident averaged 1.03, 2.75, and 1.66 mSv/y in the village of Kawauchi, the Tamano area of Soma, and the Haramachi area of Minamisoma, respectively. Internal dose rates estimated from dietary intake of radiocesium averaged 0.0058, 0.019, and 0.0088 mSv/y in Kawauchi, Tamano, and Haramachi, respectively. Dose rates from inhalation of resuspended radiocesium were lower than 0.001 mSv/y. In 2012, the average annual doses from radiocesium were close to the average background radiation exposure (2 mSv/y) in Japan. Accounting only for the physical decay of radiocesium, mean annual dose rates in 2022 were estimated as 0.31, 0.87, and 0.53 mSv/y in Kawauchi, Tamano, and Haramachi, respectively. The simple and conservative estimates are comparable with variations in the background dose, and unlikely to exceed the ordinary permissible dose rate (1 mSv/y) for the majority of the Fukushima population. Health risk assessment indicates that post-2012 doses will increase lifetime solid cancer, leukemia, and breast cancer incidences by 1.06%, 0.03% and 0.28% respectively, in Tamano. This assessment was derived from short-term observation with uncertainties and did not evaluate the first-year dose and radioiodine exposure. Nevertheless, this estimate provides perspective on the long-term radiation exposure levels in the three regions. PMID:24567380

  17. SU-E-T-558: Assessing the Effect of Inter-Fractional Motion in Esophageal Sparing Plans.

    PubMed

    Williamson, R; Bluett, J; Niedzielski, J; Liao, Z; Gomez, D; Court, L

    2012-06-01

    To compare esophageal dose distributions in esophageal sparing IMRT plans with predicted dose distributions which include the effect of inter-fraction motion. Seven lung cancer patients were used, each with a standard and an esophageal sparing plan (74Gy, 2Gy fractions). The average max dose to esophagus was 8351cGy and 7758cGy for the standard and sparing plans, respectively. The average length of esophagus for which the total circumference was treated above 60Gy (LETT60) was 9.4cm in the standard plans and 5.8cm in the sparing plans. In order to simulate inter-fractional motion, a three-dimensional rigid shift was applied to the calculated dose field. A simulated course of treatment consisted of a single systematic shift applied throughout the treatment as well a random shift for each of the 37 fractions. Both systematic and random shifts were generated from Gaussian distributions of 3mm and 5mm standard deviation. Each treatment course was simulated 1000 times to obtain an expected distribution of the delivered dose. Simulated treatment dose received by the esophagus was less than dose seen in the treatment plan. The average reduction in maximum esophageal dose for the standard plans was 234cGy and 386cGY for the 3mm and 5mm Gaussian distributions, respectively. The average reduction in LETT60 was 0.6cm and 1.7cm, for the 3mm and 5mm distributions respectively. For the esophageal sparing plans, the average reduction in maximum esophageal dose was 94cGy and 202cGy for 3mm and 5mm Gaussian distributions, respectively. The average change in LETT60 for the esophageal sparing plans was smaller, at 0.1cm (increase) and 0.6cm (reduction), for the 3mm and 5mm distributions, respectively. Interfraction motion consistently reduced the maximum doses to the esophagus for both standard and esophageal sparing plans. © 2012 American Association of Physicists in Medicine.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lesperance, Marielle; Inglis-Whalen, M.; Thomson, R. M., E-mail: rthomson@physics.carleton.ca

    Purpose : To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with{sup 125}I, {sup 103}Pd, or {sup 131}Cs seeds, and to investigate doses to ocular structures. Methods : An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom andmore » our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Results : Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20–30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%–10% and 13%–14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%–17% and 29%–34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model simulation by up to 16%. In the full eye model simulations, the average dose to the lens is larger by 7%–9% than the dose to the center of the lens, and the maximum dose to the optic nerve is 17%–22% higher than the dose to the optic disk for all radionuclides. In general, when normalized to the same prescription dose at the tumor apex, doses delivered to all structures of interest in the full eye model are lowest for{sup 103}Pd and highest for {sup 131}Cs, except for the tumor where the average dose is highest for {sup 103}Pd and lowest for {sup 131}Cs. Conclusions : The eye is not radiologically water-equivalent, as doses from simulations of the plaque in the full eye model differ considerably from doses for the plaque in a water phantom and from simulated TG-43 calculated doses. This demonstrates the importance of model-based dose calculations for eye plaque brachytherapy, for which accurate elemental compositions of ocular media are necessary.« less

  19. Estimation of effective dose and lifetime attributable risk from multiple head CT scans in ventriculoperitoneal shunted children.

    PubMed

    Aw-Zoretic, J; Seth, D; Katzman, G; Sammet, S

    2014-10-01

    The purpose of this review is to determine the averaged effective dose and lifetime attributable risk factor from multiple head computed tomography (CT) dose data on children with ventriculoperitoneal shunts (VPS). A total of 422 paediatric head CT exams were found between October 2008 and January 2011 and retrospectively reviewed. The CT dose data was weighted with the latest IRCP 103 conversion factor to obtain the effective dose per study and the averaged effective dose was calculated. Estimates of the lifetime attributable risk were also calculated from the averaged effective dose using a conversion factor from the latest BEIR VII report. Our study found the highest effective doses in neonates and the lowest effective doses were observed in the 10-18 years age group. We estimated a 0.007% potential increase risk in neonates and 0.001% potential increased risk in teenagers over the base risk. Multiple head CTs in children equates to a slight potential increase risk in lifetime attributable risk over the baseline risk for cancer, slightly higher in neonates relative to teenagers. The potential risks versus clinical benefit must be assessed. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. Fetal shielding combined with state of the art CT dose reduction strategies during maternal chest CT.

    PubMed

    Chatterson, Leslie C; Leswick, David A; Fladeland, Derek A; Hunt, Megan M; Webster, Stephen; Lim, Hyun

    2014-07-01

    Custom bismuth-antimony shields were previously shown to reduce fetal dose by 53% on an 8DR (detector row) CT scanner without dynamic adaptive section collimation (DASC), automatic tube current modulation (ATCM) or adaptive statistical iterative reconstruction (ASiR). The purpose of this study is to compare the effective maternal and average fetal organ dose reduction both with and without bismuth-antimony shields on a 64DR CT scanner using DASC, ATCM and ASiR during maternal CTPA. A phantom with gravid prosthesis and a bismuth-antimony shield were used. Thermoluminescent dosimeters (TLDs) measured fetal radiation dose. The average fetal organ dose and effective maternal dose were determined using 100 kVp, scanning from the lung apices to the diaphragm utilizing DASC, ATCM and ASiR on a 64DR CT scanner with and without shielding in the first and third trimester. Isolated assessment of DASC was done via comparing a new 8DR scan without DASC to a similar scan on the 64DR with DASC. Average third trimester unshielded fetal dose was reduced from 0.22 mGy ± 0.02 on the 8DR to 0.13 mGy ± 0.03 with the conservative 64DR protocol that included 30% ASiR, DASC and ATCM (42% reduction, P<0.01). Use of a shield further reduced average third trimester fetal dose to 0.04 mGy ± 0.01 (69% reduction, P<0.01). The average fetal organ dose reduction attributable to DASC alone was modest (6% reduction from 0.17 mGy ± 0.02 to 0.16 mGy ± 0.02, P=0.014). First trimester fetal organ dose on the 8DR protocol was 0.07 mGy ± 0.03. This was reduced to 0.05 mGy ± 0.03 on the 64DR protocol without shielding (30% reduction, P=0.009). Shields further reduced this dose to below accurately detectable levels. Effective maternal dose was reduced from 4.0 mSv on the 8DR to 2.5 mSv on the 64DR scanner using the conservative protocol (38% dose reduction). ASiR, ATCM and DASC combined significantly reduce effective maternal and fetal organ dose during CTPA. Shields continue to be an effective means of fetal dose reduction. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. Investigation of x-ray spectra for iodinated contrast-enhanced dedicated breast CT

    PubMed Central

    Glick, Stephen J.; Makeev, Andrey

    2017-01-01

    Abstract. Screening for breast cancer with mammography has been very successful, resulting in part to a reduction of breast cancer mortality by approximately 39% since 1990. However, mammography still has limitations in performance, especially for women with dense breast tissue. Iodinated contrast-enhanced, dedicated breast CT (BCT) has been proposed to improve lesion analysis and the accuracy of diagnostic workup for patients suspected of having breast cancer. A mathematical analysis to explore the use of various x-ray filters for iodinated contrast-enhanced BCT is presented. To assess task-based performance, the ideal linear observer signal-to-noise ratio (SNR) is used as a figure-of-merit under the assumptions of a linear, shift-invariant imaging system. To estimate signal and noise propagation through the BCT detector, a parallel-cascade model was used. The lesion model was embedded into a structured background and included a realistic level of iodine uptake. SNR was computed for 84,000 different exposure settings by varying the kV setting, x-ray filter materials and thickness, breast size, and composition and radiation dose. It is shown that some x-ray filter material/thickness combinations can provide up to 75% improvement in the linear ideal observer SNR over a conventionally used x-ray filter for BCT. This improvement in SNR can be traded off for substantial reductions in mean glandular dose. PMID:28149923

  2. Immunohistochemical analysis of cytochrome P4501A induction in organs and cell types of Rivulus marmoratus exposed to waterborne 2,3,7,8-tetrachlorodibenzo-p-dioxin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stegeman, J.; Smolowitz, R.; Burnett, K.

    1994-12-31

    Identifying target cells and organs is critical to establishing the sites and mechanisms of toxicity of Ah-receptor agonists. Previous studies have described the localization of CYPLA induced in multiple organs of fish exposed to Ah-receptor agonists. Here the authors compare the responses in multiple cell types and organs of small fish (Rivulus) exposed to waterborne TCDD. Adult fish were exposed to TCDD at concentrations from 0.01 to 10 ng/liter for 48 hours, then prepared and analyzed by immunohistochemistry with monoclonal antibody to teleost CYPIAI. At the highest dose profound induction was detected in virtually every organ. Structures staining intensely were:more » nasal and cephalic chemoreceptors, including sensory and basal cells; superficial cells in skin and pharynx; cartilage cells (chondrocytes) in the head, gills, growth plates and fins; epithelial and endothelial cells of liver, gut, kidney, and gill; pseudobranch vessels and glandular cells; eye lens epithelium; endothelium in vessels of eye, brain, skin, muscle, thymus and gonad. Lesser concentrations of TCDD elicited less strong responses, and control fish showed mild staining only in cartilage structures. The dose-dependent patterns of induction differed between different cell types. Responsive cells identified is these fish indicate sites where toxicity associated with Ah-receptor agonists or with CYPLA function may be expressed.« less

  3. Iatrogenic radiation exposure to patients with early onset spine and chest wall deformities.

    PubMed

    Khorsand, Derek; Song, Kit M; Swanson, Jonathan; Alessio, Adam; Redding, Gregory; Waldhausen, John

    2013-08-01

    Retrospective cohort series. Characterize average iatrogenic radiation dose to a cohort of children with thoracic insufficiency syndrome (TIS) during assessment and treatment at a single center with vertically expandable prosthetic titanium rib. Children with TIS undergo extensive evaluations to characterize their deformity. No standardized radiographical evaluation exists, but all reports use extensive imaging. The source and level of radiation these patients receive is not currently known. We evaluated a retrospective consecutive cohort of 62 children who had surgical treatment of TIS at our center from 2001-2011. Typical care included obtaining serial radiographs, spine and chest computed tomographic (CT) scans, ventilation/perfusion scans, and magnetic resonance images. Epochs of treatment were divided into time of initial evaluation to the end of initial vertically expandable prosthetic titanium rib implantation with each subsequent epoch delineated by the next surgical intervention. The effective dose for each examination was estimated within millisieverts (mSv). Plain radiographs were calculated from references. Effective dose was directly estimated for CT scans since 2007 and an average of effective dose from 2007-2011 was used for scans before 2007. Effective dose from fluoroscopy was directly estimated. All doses were reported in mSv. A cohort of 62 children had a total of 447 procedures. There were a total of 290 CT scans, 4293 radiographs, 147 magnetic resonance images, and 134 ventilation/perfusion scans. The average accumulated effective dose was 59.6 mSv for children who had completed all treatment, 13.0 mSv up to initial surgery, and 3.2 mSv for each subsequent epoch of treatment. CT scans accounted for 74% of total radiation dose. Children managed for TIS using a consistent protocol received iatrogenic radiation doses that were on average 4 times the estimated average US background radiation exposure of 3 mSv/yr. CT scans comprised 74% of the total dose. 3.

  4. Clinical implementation of a knowledge based planning tool for prostate VMAT.

    PubMed

    Powis, Richard; Bird, Andrew; Brennan, Matthew; Hinks, Susan; Newman, Hannah; Reed, Katie; Sage, John; Webster, Gareth

    2017-05-08

    A knowledge based planning tool has been developed and implemented for prostate VMAT radiotherapy plans providing a target average rectum dose value based on previously achievable values for similar rectum/PTV overlap. The purpose of this planning tool is to highlight sub-optimal clinical plans and to improve plan quality and consistency. A historical cohort of 97 VMAT prostate plans was interrogated using a RayStation script and used to develop a local model for predicting optimum average rectum dose based on individual anatomy. A preliminary validation study was performed whereby historical plans identified as "optimal" and "sub-optimal" by the local model were replanned in a blinded study by four experienced planners and compared to the original clinical plan to assess whether any improvement in rectum dose was observed. The predictive model was then incorporated into a RayStation script and used as part of the clinical planning process. Planners were asked to use the script during planning to provide a patient specific prediction for optimum average rectum dose and to optimise the plan accordingly. Plans identified as "sub-optimal" in the validation study observed a statistically significant improvement in average rectum dose compared to the clinical plan when replanned whereas plans that were identified as "optimal" observed no improvement when replanned. This provided confidence that the local model can identify plans that were suboptimal in terms of rectal sparing. Clinical implementation of the knowledge based planning tool reduced the population-averaged mean rectum dose by 5.6Gy. There was a small but statistically significant increase in total MU and femoral head dose and a reduction in conformity index. These did not affect the clinical acceptability of the plans and no significant changes to other plan quality metrics were observed. The knowledge-based planning tool has enabled substantial reductions in population-averaged mean rectum dose for prostate VMAT patients. This suggests plans are improved when planners receive quantitative feedback on plan quality against historical data.

  5. SU-E-T-318: The Effect of Patient Positioning Errors On Target Coverage and Cochlear Dose in Stereotactic Radiosurgery Treatment of Acoustic Neuromas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dellamonica, D.; Luo, G.; Ding, G.

    Purpose: Setup errors on the order of millimeters may cause under-dosing of targets and significant changes in dose to critical structures especially when planning with tight margins in stereotactic radiosurgery. This study evaluates the effects of these types of patient positioning uncertainties on planning target volume (PTV) coverage and cochlear dose for stereotactic treatments of acoustic neuromas. Methods: Twelve acoustic neuroma patient treatment plans were retrospectively evaluated in Brainlab iPlan RT Dose 4.1.3. All treatment beams were shaped by HDMLC from a Varian TX machine. Seven patients had planning margins of 2mm, five had 1–1.5mm. Six treatment plans were createdmore » for each patient simulating a 1mm setup error in six possible directions: anterior-posterior, lateral, and superiorinferior. The arcs and HDMLC shapes were kept the same for each plan. Change in PTV coverage and mean dose to the cochlea was evaluated for each plan. Results: The average change in PTV coverage for the 72 simulated plans was −1.7% (range: −5 to +1.1%). The largest average change in coverage was observed for shifts in the patient's superior direction (−2.9%). The change in mean cochlear dose was highly dependent upon the direction of the shift. Shifts in the anterior and superior direction resulted in an average increase in dose of 13.5 and 3.8%, respectively, while shifts in the posterior and inferior direction resulted in an average decrease in dose of 17.9 and 10.2%. The average change in dose to the cochlea was 13.9% (range: 1.4 to 48.6%). No difference was observed based on the size of the planning margin. Conclusion: This study indicates that if the positioning uncertainty is kept within 1mm the setup errors may not result in significant under-dosing of the acoustic neuroma target volumes. However, the change in mean cochlear dose is highly dependent upon the direction of the shift.« less

  6. A new, open-source, multi-modality digital breast phantom

    NASA Astrophysics Data System (ADS)

    Graff, Christian G.

    2016-03-01

    An anthropomorphic digital breast phantom has been developed with the goal of generating random voxelized breast models that capture the anatomic variability observed in vivo. This is a new phantom and is not based on existing digital breast phantoms or segmentation of patient images. It has been designed at the outset to be modality agnostic (i.e., suitable for use in modeling x-ray based imaging systems, magnetic resonance imaging, and potentially other imaging systems) and open source so that users may freely modify the phantom to suit a particular study. In this work we describe the modeling techniques that have been developed, the capabilities and novel features of this phantom, and study simulated images produced from it. Starting from a base quadric, a series of deformations are performed to create a breast with a particular volume and shape. Initial glandular compartments are generated using a Voronoi technique and a ductal tree structure with terminal duct lobular units is grown from the nipple into each compartment. An additional step involving the creation of fat and glandular lobules using a Perlin noise function is performed to create more realistic glandular/fat tissue interfaces and generate a Cooper's ligament network. A vascular tree is grown from the chest muscle into the breast tissue. Breast compression is performed using a neo-Hookean elasticity model. We show simulated mammographic and T1-weighted MRI images and study properties of these images.

  7. Polythelia pilosa: a particular form of accessory mammary tissue.

    PubMed

    Camacho, F; González-Cámpora, R

    1998-01-01

    The old Kajawa classification which considered eight possible forms of aberrant mammary tissue has been recently modified into a simpler one that considers this condition only when there is glandular parenchyma or when the aberrant tissue is not a glandular tissue but a nipple, an areola or both. This new classification disregards 'polythelia pilosa' defined as an 'isolated patch of hairs only'. To demonstrate that polythelia pilosa is at least a marker of subjacent accessory mammary tissue and, consequently, that the term should be incorporated into the current classification. Among 72 cases of aberrant or accessory mammary tissue, we have studied 14 cases (7 men and 7 women) that were clinically diagnosed as 'visible isolated patches of hairs, apparently without pigmentation nor structures of areola or nipple'. We excised such isolated patches in 3 women. The histopathological examination showed an acanthotic and hyperpigmented epithelium with central depression closed by keratin plugs; in the dermis there were follicles with hairs surrounded by hypertrophic sebaceous glands. In the deepest portion, abundant secretory glomerules and excretory ducts of apocrine gland type could be observed. Since the biopsy of isolated patches of hairs demonstrated structures of either areolar or apocrine glandular tissue, we think that the term 'polythelia pilosa' should be reinstated into the classification as it is at least a marker of true aberrant mammary structures in men and hirsute women.

  8. Molecular cloning and functional characterization of borneol dehydrogenase from the glandular trichomes of Lavandula x intermedia.

    PubMed

    Sarker, Lukman S; Galata, Mariana; Demissie, Zerihun A; Mahmoud, Soheil S

    2012-12-15

    Several varieties of Lavandula x intermedia (lavandins) are cultivated for their essential oils (EOs) for use in cosmetic, hygiene and personal care products. These EOs are mainly constituted of monoterpenes including camphor, which contributes an off odor reducing the olfactory appeal of the oil. We have recently constructed a cDNA library from the glandular trichomes (the sites of EO synthesis) of L. x intermedia plants. Here, we describe the cloning of a borneol dehydrogenase cDNA (LiBDH) from this library. The 780 bp open reading frame of the cDNA encoded a 259 amino acid short chain alcohol dehydrogenase with a predicted molecular mass of ca. 27.5 kDa. The recombinant LiBDH was expressed in Escherichia coli, purified by Ni-NTA agarose affinity chromatography, and functionally characterized in vitro. The bacterially produced enzyme specifically converted borneol to camphor as the only product with K(m) and k(cat) values of 53 μM and 4.0 × 10(-4) s(-1), respectively. The LiBDH transcripts were specifically expressed in glandular trichomes of mature flowers indicating that like other Lavandula monoterpene synthases the expression of this gene is regulated in a tissue-specific manner. The cloning of LiBDH has far reaching implications in improving the quality of Lavandula EOs through metabolic engineering. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Spirocerca vulpis sp. nov. (Spiruridae: Spirocercidae): description of a new nematode species of the red fox, Vulpes vulpes (Carnivora: Canidae).

    PubMed

    Rojas, Alicia; Sanchis-Monsonís, Gloria; Alić, Amer; Hodžić, Adnan; Otranto, Domenico; Yasur-Landau, Daniel; Martínez-Carrasco, Carlos; Baneth, Gad

    2018-05-21

    Previous studies have reported nematodes of the Spirocercidae family in the stomach nodules of red foxes (Vulpes vulpes) described as Spirocerca sp. or Spirocerca lupi (Rudolphi, 1819). We characterized spirurid worms collected from red foxes and compared them to S. lupi from domestic dogs by morphometric and phylogenetic analyses. Nematodes from red foxes differed from S. lupi by the presence of six triangular teeth-like buccal capsule structures, which are absent in the latter. Additionally, in female worms from red foxes, the distance of the vulva opening to the anterior end and the ratio of the glandular-to-muscular oesophagus lengths were larger than those of S. lupi (P < 0.006). In males, the lengths of the whole oesophagus and glandular part, the ratio of the glandular-to-muscular oesophagus and the comparison of the oesophagus to the total body length were smaller in S. lupi (all P < 0.044). Phylogenetic analyses revealed that S. lupi and the red foxes spirurid represent monophyletic sister groups with pairwise nucleotide distances of 9.2 and 0.2% in the cytochrome oxidase 1 and 18S genes, respectively. Based on these comparisons, the nematodes from red foxes were considered to belong to a separate species, for which the name Spirocerca vulpis sp. nov. is proposed.

  10. Comparative effects of in ovo exposure to sodium perchlorate on development, growth, metabolism, and thyroid function in the common snapping turtle (Chelydra serpentina) and red-eared slider (Trachemys scripta elegans).

    PubMed

    Eisenreich, Karen M; Dean, Karen M; Ottinger, Mary Ann; Rowe, Christopher L

    2012-11-01

    Perchlorate is a surface and groundwater contaminant found in areas associated with munitions and rocket manufacturing and use. It is a thyroid-inhibiting compound, preventing uptake of iodide by the thyroid gland, ultimately reducing thyroid hormone production. As thyroid hormones influence metabolism, growth, and development, perchlorate exposure during the embryonic period may impact embryonic traits that ultimately influence hatchling performance. We topically exposed eggs of red-eared sliders (Trachemys scripta) and snapping turtles (Chelydra serpentina) to 200 and 177 μg/g of perchlorate (as NaClO(4)), respectively, to determine impacts on glandular thyroxine concentrations, embryonic growth and development, and metabolic rates of hatchlings for a period of 2 months post-hatching. In red-eared sliders, in ovo perchlorate exposure delayed hatching, increased external yolk size at hatching, increased hatchling mortality, and reduced total glandular thyroxine concentrations in hatchlings. In snapping turtles, hatching success and standard metabolic rates were reduced, liver and thyroid sizes were increased, and total glandular thyroxine concentrations in hatchlings were reduced after exposure to perchlorate. While both species were negatively affected by exposure, impacts on red-eared sliders were most severe, suggesting that the slider may be a more sensitive sentinel species for studying effects of perchlorate exposure to turtles. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Surgical Strategies in the Treatment of Gynecomastia Grade I-II: The Combination of Liposuction and Subcutaneous Mastectomy Provides Excellent Patient Outcome and Satisfaction.

    PubMed

    Schröder, Lars; Rudlowski, Christian; Walgenbach-Brünagel, Gisela; Leutner, Claudia; Kuhn, Walther; Walgenbach, Klaus-Jürgen

    2015-07-01

    Gynecomastia (GM) is a benign condition with glandular tissue enlargement of the male breast. GM is classified into 4 grades of increasing severity. We describe a series of GM grade I-II, diagnosed, treated surgically and analyzed regarding feasibility, complication rate, and satisfaction. From 2005 to 2012, a chart review was performed for 53 patients. Preoperative examination included endocrine and urological examination and exclusion of other pathological conditions. The surgical technique consisted of liposuction through an inframammarian-fold incision and excision of the glandular tissue by a minimal periareolar approach. A total number of 53 male patients with 104 breasts were available for analysis. By liposuction, a median of 300 ml (range: 10-1000 ml) was aspirated from each breast and 25.1 g (range: 3-233 g) gland tissue was resected. Surgery lasted between 25 and 164 min per patient (median: 72 min). 2 postoperative hemorrhages occurred (n = 2, 3.8%). 2 patients underwent re-operation due to cosmetic reasons (n = 2, 3.8%). This analysis demonstrates that treatment of GM grade I-II can easily be performed by liposuction combined with subcutaneous resection of the glandular tissue as a minimally invasive and low-impact surgical treatment with a low rate of complications and excellent patient satisfaction. Preoperative workup is important to rule out specific diseases or malignancy causing the GM.

  12. Surgical correction of gynecomastia with minimal scarring.

    PubMed

    Lee, Jun-Ho; Kim, Il-Kug; Kim, Tae-Gon; Kim, Yong-Ha

    2012-12-01

    Gynecomastia is a benign, excessive development of the male breast that occurs at an overall incidence of 32-36 %. The authors effectively removed peripheral fat tissues with power-assisted liposuction (PAL) and periareolar glandular tissues with a cartilage shaver in a series of patients. The small periareolar incisions were not easily recognized. Between February 2010 and April 2012, the charts of 15 patients (28 breasts) treated with PAL and a cartilage shaver were retrospectively reviewed. The mean volume of fat tissue removed with liposuction was 319 mL, and the mean volume of glandular tissue removed with the cartilage shaver was 70 mL. The mean follow-up period was 11.2 months. No infection, nipple-areola complex necrosis, nipple retraction, or saucer deformity was encountered in this series. Intraoperative bleeding occurred in one patient. Mild asymmetries developed in three patients. Use of PAL and a cartilage shaver for the treatment of gynecomastia allows for effective removal of both the fat and the glandular tissue of the breast through a minimal periareolar incision. This technique can achieve excellent aesthetic results with inconspicuous scarring. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  13. A new species of Xenoturbella from the western Pacific Ocean and the evolution of Xenoturbella.

    PubMed

    Nakano, Hiroaki; Miyazawa, Hideyuki; Maeno, Akiteru; Shiroishi, Toshihiko; Kakui, Keiichi; Koyanagi, Ryo; Kanda, Miyuki; Satoh, Noriyuki; Omori, Akihito; Kohtsuka, Hisanori

    2017-12-18

    Xenoturbella is a group of marine benthic animals lacking an anus and a centralized nervous system. Molecular phylogenetic analyses group the animal together with the Acoelomorpha, forming the Xenacoelomorpha. This group has been suggested to be either a sister group to the Nephrozoa or a deuterostome, and therefore it may provide important insights into origins of bilaterian traits such as an anus, the nephron, feeding larvae and centralized nervous systems. However, only five Xenoturbella species have been reported and the evolutionary history of xenoturbellids and Xenacoelomorpha remains obscure. Here we describe a new Xenoturbella species from the western Pacific Ocean, and report a new xenoturbellid structure - the frontal pore. Non-destructive microCT was used to investigate the internal morphology of this soft-bodied animal. This revealed the presence of a frontal pore that is continuous with the ventral glandular network and which exhibits similarities with the frontal organ in acoelomorphs. Our results suggest that large size, oval mouth, frontal pore and ventral glandular network may be ancestral features for Xenoturbella. Further studies will clarify the evolutionary relationship of the frontal pore and ventral glandular network of xenoturbellids and the acoelomorph frontal organ. One of the habitats of the newly identified species is easily accessible from a marine station and so this species promises to be valuable for research on bilaterian and deuterostome evolution.

  14. Evolution of oil-producing trichomes in Sisyrinchium (Iridaceae): insights from the first comprehensive phylogenetic analysis of the genus

    PubMed Central

    Chauveau, Olivier; Eggers, Lilian; Raquin, Christian; Silvério, Adriano; Brown, Spencer; Couloux, Arnaud; Cruaud, Corine; Kaltchuk-Santos, Eliane; Yockteng, Roxana; Souza-Chies, Tatiana T.; Nadot, Sophie

    2011-01-01

    Background and Aims Sisyrinchium (Iridaceae: Iridoideae: Sisyrinchieae) is one of the largest, most widespread and most taxonomically complex genera in Iridaceae, with all species except one native to the American continent. Phylogenetic relationships within the genus were investigated and the evolution of oil-producing structures related to specialized oil-bee pollination examined. Methods Phylogenetic analyses based on eight molecular markers obtained from 101 Sisyrinchium accessions representing 85 species were conducted in the first extensive phylogenetic analysis of the genus. Total evidence analyses confirmed the monophyly of the genus and retrieved nine major clades weakly connected to the subdivisions previously recognized. The resulting phylogenetic hypothesis was used to reconstruct biogeographical patterns, and to trace the evolutionary origin of glandular trichomes present in the flowers of several species. Key Results and Conclusions Glandular trichomes evolved three times independently in the genus. In two cases, these glandular trichomes are oil-secreting, suggesting that the corresponding flowers might be pollinated by oil-bees. Biogeographical patterns indicate expansions from Central America and the northern Andes to the subandean ranges between Chile and Argentina and to the extended area of the Paraná river basin. The distribution of oil-flower species across the phylogenetic trees suggests that oil-producing trichomes may have played a key role in the diversification of the genus, a hypothesis that requires future testing. PMID:21527419

  15. Quantitative structural markers of colorectal dysplasia in a cross sectional study of ex vivo murine tissue using label-free multiphoton microscopy

    NASA Astrophysics Data System (ADS)

    Prieto, Sandra P.; Greening, Gage J.; Lai, Keith K.; Muldoon, Timothy J.

    2016-03-01

    Two-photon excitation of label-free tissue is of increasing interest, as advances have been made in endoscopic clinical application of multiphoton microscopy, such as second harmonic generation (SHG) scanning endoscopy used to monitor cervical collagen in mice1. We used C57BL mice as a model to investigate the progression of gastrointestinal structures, specifically glandular area and circularity. We used multiphoton microscopy to image ex-vivo label-free murine colon, focusing on the collagen structure changes over time, in mice ranging from 10 to 20 weeks of age. Series of images were acquired within the colonic and intestinal tissue at depth intervals of 20 microns from muscularis to the epithelium, up to a maximum depth of 180 microns. The imaging system comprised a two-photon laser tuned to 800nm wavelength excitation, and the SHG emission was filtered with a 400/40 bandpass filter before reaching the photomultiplier tube. Images were acquired at 15 frames per second, for 200 to 300 cumulative frames, with a field of view of 261um by 261um, and 40mW at sample. Image series were compared to histopathology H&E slides taken from adjacent locations. Quantitative metrics for determining differences between murine glandular structures were applied, specifically glandular area and circularity.

  16. A Geranylfarnesyl Diphosphate Synthase Provides the Precursor for Sesterterpenoid (C25) Formation in the Glandular Trichomes of the Mint Species Leucosceptrum canum

    PubMed Central

    Luo, Shi-Hong; Schmidt, Axel; Sun, Gui-Ling; Kuang, Ce; Yang, Min-Jie; Jing, Shu-Xi; Li, Chun-Huan

    2016-01-01

    Plant sesterterpenoids, an important class of terpenoids, are widely distributed in various plants, including food crops. However, little is known about their biosynthesis. Here, we cloned and functionally characterized a plant geranylfarnesyl diphosphate synthase (Lc-GFDPS), the enzyme producing the C25 prenyl diphosphate precursor to all sesterterpenoids, from the glandular trichomes of the woody plant Leucosceptrum canum. GFDPS catalyzed the formation of GFDP after expression in Escherichia coli. Overexpressing GFDPS in Arabidopsis thaliana also gave an extract catalyzing GFDP formation. GFDPS was strongly expressed in glandular trichomes, and its transcript profile was completely in accordance with the sesterterpenoid accumulation pattern. GFDPS is localized to the plastids, and inhibitor studies indicated its use of isoprenyl diphosphate substrates supplied by the 2-C-methyl-d-erythritol 4-phosphate pathway. Application of a jasmonate defense hormone induced GFDPS transcript and sesterterpenoid accumulation, while reducing feeding and growth of the generalist insect Spodoptera exigua, suggesting that these C25 terpenoids play a defensive role. Phylogenetic analysis suggested that GFDPS probably evolved from plant geranylgeranyl diphosphate synthase under the influence of positive selection. The isolation of GFDPS provides a model for investigating sesterterpenoid formation in other species and a tool for manipulating the formation of this group in plants and other organisms. PMID:26941091

  17. EST Analysis of Hop Glandular Trichomes Identifies an O-Methyltransferase That Catalyzes the Biosynthesis of Xanthohumol[W][OA

    PubMed Central

    Nagel, Jana; Culley, Lana K.; Lu, Yuping; Liu, Enwu; Matthews, Paul D.; Stevens, Jan F.; Page, Jonathan E.

    2008-01-01

    The glandular trichomes (lupulin glands) of hop (Humulus lupulus) synthesize essential oils and terpenophenolic resins, including the bioactive prenylflavonoid xanthohumol. To dissect the biosynthetic processes occurring in lupulin glands, we sequenced 10,581 ESTs from four trichome-derived cDNA libraries. ESTs representing enzymes of terpenoid biosynthesis, including all of the steps of the methyl 4-erythritol phosphate pathway, were abundant in the EST data set, as were ESTs for the known type III polyketide synthases of bitter acid and xanthohumol biosynthesis. The xanthohumol biosynthetic pathway involves a key O-methylation step. Four S-adenosyl-l-methionine–dependent O-methyltransferases (OMTs) with similarity to known flavonoid-methylating enzymes were present in the EST data set. OMT1, which was the most highly expressed OMT based on EST abundance and RT-PCR analysis, performs the final reaction in xanthohumol biosynthesis by methylating desmethylxanthohumol to form xanthohumol. OMT2 accepted a broad range of substrates, including desmethylxanthohumol, but did not form xanthohumol. Mass spectrometry and proton nuclear magnetic resonance analysis showed it methylated xanthohumol to 4-O-methylxanthohumol, which is not known from hop. OMT3 was inactive with all substrates tested. The lupulin gland-specific EST data set expands the genomic resources for H. lupulus and provides further insight into the metabolic specialization of glandular trichomes. PMID:18223037

  18. Linear glandular trichomes of Helianthus (Asteraceae): morphology, localization, metabolite activity and occurrence

    PubMed Central

    Aschenbrenner, Anna-Katharina; Horakh, Silke; Spring, Otmar

    2013-01-01

    Capitate glandular trichomes of sunflower are well investigated, but detailed studies are lacking for the linear glandular trichomes (LGT), a second type of physiologically active plant hair present on the surface of sunflowers. Light, fluorescence and scanning electron microscopy as well as histochemical staining were used to investigate the structure and metabolite deposition of LGT. Consisting of 6–11 linearly arranged cells, LGT were found on the surface of most plant organs of Helianthus annuus. They were associated with the leaf vascular system, and also occurred along petioles, stems and the abaxial surface of chaffy bracts, ray and disc florets. The highest density was found on the abaxial surface of phyllaries. Phenotypically similar LGT were common in all species of the genus, but also occurred in most other genera of the Helianthinae so far screened. Brownish and fluorescent metabolites of an as yet unknown chemical structure, together with terpenoids, were produced and stored in apical cells of LGT. The deposition of compounds gradually progressed from the tip cell to the basal cells of older trichomes. This process was accompanied by nucleus degradation in metabolite-accumulating cells. The localization of these trichomes on prominent plant parts of the apical bud and the capitulum combined with the accumulation of terpenoids and other as yet unknown compounds suggests a chemo-ecological function of the LGT in plant–insect or plant–herbivore interaction.

  19. Revision of orthovoltage chest wall treatment using Monte Carlo simulations.

    PubMed

    Zeinali-Rafsanjani, B; Faghihi, R; Mosleh-Shirazi, M A; Mosalaei, A; Hadad, K

    2017-01-01

    Given the high local control rates observed in breast cancer patients undergoing chest wall irradiation by kilovoltage x-rays, we aimed to revisit this treatment modality by accurate calculation of dose distributions using Monte Carlo simulation. The machine components were simulated using the MCNPX code. This model was used to assess the dose distribution of chest wall kilovoltage treatment in different chest wall thicknesses and larger contour or fat patients in standard and mid sternum treatment plans. Assessments were performed at 50 and 100 cm focus surface distance (FSD) and different irradiation angles. In order to evaluate different plans, indices like homogeneity index, conformity index, the average dose of heart, lung, left anterior descending artery (LAD) and percentage target coverage (PTC) were used. Finally, the results were compared with the indices provided by electron therapy which is a more routine treatment of chest wall. These indices in a medium chest wall thickness in standard treatment plan at 50 cm FSD and 15 degrees tube angle was as follows: homogeneity index 2.57, conformity index 7.31, average target dose 27.43 Gy, average dose of heart, lung and LAD, 1.03, 2.08 and 1.60 Gy respectively and PTC 11.19%. Assessments revealed that dose homogeneity in planning target volume (PTV) and conformity between the high dose region and PTV was poor. To improve the treatment indices, the reference point was transferred from the chest wall skin surface to the center of PTV. The indices changed as follows: conformity index 7.31, average target dose 60.19 Gy, the average dose of heart, lung and LAD, 3.57, 6.38 and 5.05 Gy respectively and PTC 55.24%. Coverage index of electron therapy was 89% while it was 22.74% in the old orthovoltage method and also the average dose of the target was about 50 Gy but in the given method it was almost 30 Gy. The results of the treatment study show that the optimized standard and mid sternum treatment for different chest wall thicknesses is with 50 cm FSD and zero (vertical) tube angle, while in large contour patients, it is with 100 cm FSD and zero tube angle. Finally, chest wall kilovoltage and electron therapies were compared, which revealed that electron therapy produces a better dose distribution than kilovoltage therapy.

  20. 27 CFR 21.33 - Formula No. 2-B.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... crude drugs. 342.Processing glandular products, vitamins, hormones, and yeasts. 343.Processing.... (3) Miscellaneous uses: 812.Product development and pilot plant uses (own use only). (c) Conditions...

  1. 27 CFR 21.33 - Formula No. 2-B.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... crude drugs. 342.Processing glandular products, vitamins, hormones, and yeasts. 343.Processing.... (3) Miscellaneous uses: 812.Product development and pilot plant uses (own use only). (c) Conditions...

  2. 27 CFR 21.33 - Formula No. 2-B.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... crude drugs. 342.Processing glandular products, vitamins, hormones, and yeasts. 343.Processing.... (3) Miscellaneous uses: 812.Product development and pilot plant uses (own use only). (c) Conditions...

  3. 27 CFR 21.33 - Formula No. 2-B.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... crude drugs. 342.Processing glandular products, vitamins, hormones, and yeasts. 343.Processing.... (3) Miscellaneous uses: 812.Product development and pilot plant uses (own use only). (c) Conditions...

  4. Daily radionuclide ingestion and internal radiation doses in Aomori prefecture, Japan.

    PubMed

    Ohtsuka, Yoshihito; Kakiuchi, Hideki; Akata, Naofumi; Takaku, Yuichi; Hisamatsu, Shun'ichi

    2013-10-01

    To assess internal annual dose in the general public in Aomori Prefecture, Japan, 80 duplicate cooked diet samples, equivalent to the food consumed over a 400-d period by one person, were collected from 100 volunteers in Aomori City and the village of Rokkasho during 2006–2010 and were analyzed for 11 radionuclides. To obtain average rates of ingestion of radionuclides, the volunteers were selected from among office, fisheries, agricultural, and livestock farm workers. Committed effective doses from ingestion of the diet over a 1-y period were calculated from the analytical results and from International Commission on Radiological Protection dose coefficients; for 40K, an internal effective dose rate from the literature was used. Fisheries workers had significantly higher combined internal annual dose than the other workers, possibly because of high rates of ingestion of marine products known to have high 210Po concentrations. The average internal dose rate, weighted by the numbers of households in each worker group in Aomori Prefecture, was estimated at 0.47 mSv y-1. Polonium-210 contributed 49% of this value. The sum of committed effective dose rates for 210Po, 210Pb, 228Ra, and 14C and the effective dose rate of 40K accounted for approximately 99% of the average internal dose rate.

  5. Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume.

    PubMed

    Admiraal, Marjan A; Schuring, Danny; Hurkmans, Coen W

    2008-01-01

    The purpose of this study was to determine the 4D accumulated dose delivered to the CTV in stereotactic radiotherapy of lung tumours, for treatments planned on an average CT using an ITV derived from the Maximum Intensity Projection (MIP) CT. For 10 stage I lung cancer patients, treatment plans were generated based on 4D-CT images. From the 4D-CT scan, 10 time-sorted breathing phases were derived, along with the average CT and the MIP. The ITV with a margin of 0mm was used as a PTV to study a worst case scenario in which the differences between 3D planning and 4D dose accumulation will be largest. Dose calculations were performed on the average CT. Dose prescription was 60Gy to 95% of the PTV, and at least 54Gy should be received by 99% of the PTV. Plans were generated using the inverse planning module of the Pinnacle(3) treatment planning system. The plans consisted of nine coplanar beams with two segments each. After optimisation, the treatment plan was transferred to all breathing phases and the delivered dose per phase was calculated using an elastic body spline model available in our research version of Pinnacle (8.1r). Then, the cumulative dose to the CTV over all breathing phases was calculated and compared to the dose distribution of the original treatment plan. Although location, tumour size and breathing-induced tumour movement varied widely between patients, the PTV planning criteria could always be achieved without compromising organs at risk criteria. After 4D dose calculations, only very small differences between the initial planned PTV coverage and resulting CTV coverage were observed. For all patients, the dose delivered to 99% of the CTV exceeded 54Gy. For nine out of 10 patients also the criterion was met that the volume of the CTV receiving at least the prescribed dose was more than 95%. When the target dose is prescribed to the ITV (PTV=ITV) and dose calculations are performed on the average CT, the cumulative CTV dose compares well to the planned dose to the ITV. Thus, the concept of treatment plan optimisation and evaluation based on the average CT and the ITV is a valid approach in stereotactic lung treatment. Even with a zero ITV to PTV margin, no significantly different dose coverage of the CTV arises from the breathing motion induced dose variation over time.

  6. Effect of ketoconazole on cyclosporine dose in healthy dogs.

    PubMed

    Dahlinger, J; Gregory, C; Bea, J

    1998-01-01

    To determine the degree to which the dose of oral cyclosporine (CyA), in healthy dogs, can be decreased by concurrent oral administration of ketoconazole. Dogs in this study were observed for physical or biochemical side effects that might have been caused by the administration of CyA and ketoconazole. Prospective research study. Five healthy, intact female Beagle dogs. CyA was administered orally twice daily to achieve stable whole blood trough levels of 400 to 600 ng/mL. Ketoconazole was added at a low therapeutic dose (average dose: 13.6 mg/kg/d) then at a subtherapeutic dose (average dose: 4.7 mg/kg/d). CyA whole blood trough levels were monitored every 3 to 4 days and maintained at 400 to 600 ng/mL by adjusting CyA doses accordingly. Physical examination, CBC, biochemical profile, and urinalysis were performed at 2-week intervals throughout the study period. The initial mean dose of CyA required to achieve target blood levels was 14.5 mg/ kg/d. With concurrent ketoconazole (low therapeutic dose, average dose: 13.6 mg/kg/d) and CyA administration, the CyA dose declined to 3.4 mg/kg/day (range: 1.2 to 5.2 mg/kg/d), representing a 75% reduction in CyA dose and monetary savings of 57.8%. At a subtherapeutic dose of ketoconazole (average dose: 4.7 mg/kg/d), combination therapy resulted in a CyA dose of 10.1 mg/kg/day (4.9 to 10.6 mg/kg/d), representing a 38% reduction in CyA dose and monetary savings of 23.8%. Weight loss and transient hypoalbuminemia of unknown clinical significance were observed. Other physical and biochemical evaluations were unremarkable over the 12-week study period. The oral administration of ketoconazole can be used to reduce substantially the oral CyA dose needed to maintain selected blood levels in healthy dogs. The oral administration of ketoconazole can result in substantial cost savings to owners of dogs receiving CyA after renal allograft transplantation or for the treatment of autoimmune disease.

  7. Dense Breasts

    MedlinePlus

    ... fatty tissue. On a mammogram, fatty tissue appears dark (radio-lucent) and the glandular and connective tissues ... white on mammography) and non-dense fatty tissue (dark on mammography) using a visual scale and assign ...

  8. Acute glandular fever-like illness in a patient with HTLV-III antibody.

    PubMed

    McCaul, T F; Tovey, G; Farthing, C F; Gazzard, B; Zuckerman, A J

    1985-10-01

    A lymph node biopsy obtained from a patient with human T-cell lymphocytotropic virus III/lymphadenopathy-associated virus (HTLV-III/LAV) antibody, presenting with an acute glandular fever-like illness, was examined by electron microscopy. Numerous pathological changes were present in the biopsy, including hypertrophy of smooth endoplasmic reticulum, intracytoplasmic rod-like inclusions within the cisternae of endoplasmic reticulum, multivesicular bodies, test-tube and ring-shaped forms, and tubulo-reticular structures. Intranuclear and intracytoplasmic viral-like particles measuring 105-120 nm in diameter and small cytoplasmic particles measuring 50-70 nm in diameter were found in some degenerating lymph node cells. These pathological findings may reflect a host cell response to various pathological and viral stimuli resulting from immune deficiency owing to infection with HTLV-III/LAV.

  9. Basal cell adenocarcinoma in the gland of the third eyelid of a brown bear (Ursus arctos)

    PubMed Central

    SAKAI, Hiroki; GOTO, Minami; KOMATSU, Takeshi

    2017-01-01

    The right third eyelid of an adult female brown bear (c) was swollen and removed. Histopathology revealed a tumor exhibiting proliferation with mild infiltration, consisting of multi-stratified glandular structures of the innermost laminal neoplastic cells and the basaloid neoplastic cells, and with eosinophilic thick basal lamina material around the glandular structures. Both types of neoplastic cells exhibited moderate anisokaryosis, and mitotic figures were observed in the basaloid neoplastic cells. The laminal neoplastic cells were cytokeratin (CK) 8/18-positive. In contrast, the basaloid neoplastic cells were CK14- and p63-positive, but α-smooth muscle actin- and calponin-negative. The case described herein is the first report of basal cell adenocarcinoma in the gland of the third eyelid of a bear. PMID:28637946

  10. Mixed gynecomastia.

    PubMed

    Al Qassabi, Salim S; Al-Harthi, Saud M; Al-Osali, Magdi E

    2015-09-01

    Gynecomastia is an enlargement of male breast resulting from a proliferation of its glandular component, and it is usually due to an altered estrogen-androgen balance. It should be differentiated from pseudogynecomastia, which is characterized by fat deposition without glandular proliferation and from breast carcinoma. Gynecomastia could be physiological in neonates and pubertal or pathological due to drug intake, chronic liver, or renal disease, hyperthyroidism, testicular or adrenal neoplasms, and hypogonadism whether primary, or secondary. Properly organized work-up is needed to reach the cause of gynecomastia. Here, we reported a case of a young Omani man with gynecomastia with the aim of creating awareness of the occurrence of Klinefelter's syndrome (KS) in patients with gynecomastia, to observe any differences in clinical presentation of KS from those reported in the literature, and highlight the needed diagnostic work-up and treatment.

  11. Evaluation of external and internal irradiation on uranium mining enterprise staff by tooth enamel EPR spectroscopy

    NASA Astrophysics Data System (ADS)

    Zhumadilov, Kassym; Ivannikov, Alexander; Khailov, Artem; Orlenko, Sergei; Skvortsov, Valeriy; Stepanenko, Valeriy; Kuterbekov, Kairat; Toyoda, Shin; Kazymbet, Polat; Hoshi, Masaharu

    2017-11-01

    In order to estimate radiation effects on uranium enterprise staff and population teeth samples were collected for EPR tooth enamel dosimetry from population of Stepnogorsk city and staff of uranium mining enterprise in Shantobe settlment (Akmola region, North of Kazakhstan). By measurements of tooth enamel EPR spectra, the total absorbed dose in the enamel samples and added doses after subtraction of the contribution of natural background radiation are determined. For the population of Stepnogorsk city average added dose value of 4 +/- 11 mGy with variation of 51 mGy was obtained. For the staff of uranium mining enterprise in Shantobe settlment average value of added dose 95 +/- 20 mGy, with 85 mGy variation was obtained. Higher doses and the average value and a large variation for the staff, probably is due to the contribution of occupational exposure.

  12. Estimated radiation exposure of German commercial airline cabin crew in the years 1960-2003 modeled using dose registry data for 2004-2015.

    PubMed

    Wollschläger, Daniel; Hammer, Gaël Paul; Schafft, Thomas; Dreger, Steffen; Blettner, Maria; Zeeb, Hajo

    2018-05-01

    Exposure to ionizing radiation of cosmic origin is an occupational risk factor in commercial aircrew. In a historic cohort of 26,774 German aircrew, radiation exposure was previously estimated only for cockpit crew using a job-exposure matrix (JEM). Here, a new method for retrospectively estimating cabin crew dose is developed. The German Federal Radiation Registry (SSR) documents individual monthly effective doses for all aircrew. SSR-provided doses on 12,941 aircrew from 2004 to 2015 were used to model cabin crew dose as a function of age, sex, job category, solar activity, and male pilots' dose; the mean annual effective dose was 2.25 mSv (range 0.01-6.39 mSv). In addition to an inverse association with solar activity, exposure followed age- and sex-dependent patterns related to individual career development and life phases. JEM-derived annual cockpit crew doses agreed with SSR-provided doses for 2004 (correlation 0.90, 0.40 mSv root mean squared error), while the estimated average annual effective dose for cabin crew had a prediction error of 0.16 mSv, equaling 7.2% of average annual dose. Past average annual cabin crew dose can be modeled by exploiting systematic external influences as well as individual behavioral determinants of radiation exposure, thereby enabling future dose-response analyses of the full aircrew cohort including measurement error information.

  13. Effects of pH and dose on nasal absorption of scopolamine hydrobromide in human subjects

    NASA Technical Reports Server (NTRS)

    Ahmed, S.; Sileno, A. P.; deMeireles, J. C.; Dua, R.; Pimplaskar, H. K.; Xia, W. J.; Marinaro, J.; Langenback, E.; Matos, F. J.; Putcha, L.; hide

    2000-01-01

    PURPOSE: The present study was conducted to evaluate the effects of formulation pH and dose on nasal absorption of scopolamine hydrobromide, the single most effective drug available for the prevention of nausea and vomiting induced by motion sickness. METHODS: Human subjects received scopolamine nasally at a dose of 0.2 mg/0.05 mL or 0.4 mg/0.10 mL, blood samples were collected at different time points, and plasma scopolamine concentrations were determined by LC-MS/MS. RESULTS: Following administration of a 0.2 mg dose, the average Cmax values were found to be 262+/-118, 419+/-161, and 488+/-331 pg/ mL for pH 4.0, 7.0, and 9.0 formulations, respectively. At the 0.4 mg dose the average Cmax values were found to be 503+/-199, 933+/-449, and 1,308+/-473 pg/mL for pH 4.0, 7.0, and 9.0 formulations, respectively. At a 0.2 mg dose, the AUC values were found to be 23,208+/-6,824, 29,145+/-9,225, and 25,721+/-5,294 pg x min/mL for formulation pH 4.0, 7.0, and 9.0, respectively. At a 0.4 mg dose, the average AUC value was found to be high for pH 9.0 formulation (70,740+/-29,381 pg x min/mL) as compared to those of pH 4.0 (59,573+/-13,700 pg x min/mL) and pH 7.0 (55,298+/-17,305 pg x min/mL) formulations. Both the Cmax and AUC values were almost doubled with doubling the dose. On the other hand, the average Tmax, values decreased linearly with a decrease in formulation pH at both doses. For example, at a 0.4 mg dose, the average Tmax values were 26.7+/-5.8, 15.0+/-10.0, and 8.8+/-2.5 minutes at formulation pH 4.0, 7.0, and 9.0, respectively. CONCLUSIONS: Nasal absorption of scopolamine hydrobromide in human subjects increased substantially with increases in formulation pH and dose.

  14. TU-EF-304-09: Quantifying the Biological Effects of Therapeutic Protons by LET Spectrum Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guan, F; Bronk, L; Kerr, M

    2015-06-15

    Purpose: To correlate in vitro cell kill with linear energy transfer (LET) spectra using Monte Carlo simulations and knowledge obtained from previous high-throughput in vitro proton relative biological effectiveness (RBE) measurements. Methods: The Monte Carlo simulation toolkit Geant4 was used to design the experimental setups and perform the dose, dose-averaged LET, and LET spectra calculations. The clonogenic assay was performed using the H460 lung cancer cell line in standard 6-well plates. Using two different experimental setups, the same dose and dose-averaged LET (12.6 keV/µm) was delivered to the cell layer; however, each respective energy or LET spectrum was different. Wemore » quantified the dose contributions from high-LET (≥10 keV/µm, threshold determined by previous RBE measurements) events in the LET spectra separately for these two setups as 39% and 53%. 8 dose levels with 1 Gy increments were delivered. The photon reference irradiation was performed using 6 MV x-rays from a LINAC. Results: The survival curves showed that both proton irradiations demonstrated an increased RBE compared to the reference photon irradiation. Within the proton-irradiated cells, the setup with 53% dose contribution from high-LET events exhibited the higher biological effectiveness. Conclusion: The experimental results indicate that the dose-averaged LET may not be an appropriate indicator to quantify the biological effects of protons when the LET spectrum is broad enough to contain both low- and high-LET events. Incorporating the LET spectrum distribution into robust intensity-modulated proton therapy optimization planning may provide more accurate biological dose distribution than using the dose-averaged LET. NIH Program Project Grant 2U19CA021239-35.« less

  15. Bone cancer occurrence among beagles given 239Pu as young adults.

    PubMed

    Lloyd, R D; Taylor, G N; Angus, W; Bruenger, F W; Miller, S C

    1993-01-01

    The occurrence of skeletal malignancies has been documented among 234 young adult beagles given single intravenous injections of monomeric 239Pu citrate. Occurrence has also been documented among 132 comparable control group animals surviving the minimum latent time period of 2.79 y for radiation-induced bone cancer, who were maintained for lifespan observation. Injected amounts ranged from about 0.02-106 kBq kg-1 body mass with factors of 2 or 3 between dose levels. There were 84 radiographically apparent bone tumors in 76 plutonium-injected dogs and one tumor in a control group dog. Most of these were osteosarcomas except for seven chondrosarcomas, one liposarcoma, and one plasma cell myeloma of bone. The relationship between percent of dogs at any dose level with bone malignancy and average skeletal dose at the presumed time of tumor initiation of 1 y before death appeared to be linear below about 1.3 Gy average skeletal dose. The observed data can be approximated by the expression A = 0.76 + 75 D, where A = percent of dogs with bone cancer at any dose level, D = average skeletal dose in Gy (for doses up to 1.3 Gy) at tumor initiation, and 0.76 represents the percent tumor response in the control animals not given plutonium. Similar analysis of our corresponding data for beagles given 226Ra, excluding the two highest dose levels (approximately 100% occurrence), yielded the expression A = 0.76 + 4.7 D, where D = the average skeletal dose in Gy (for doses up to 20 Gy) at 1 y before death. The ratio of coefficients indicates the effectiveness for bone cancer induction of 239Pu relative to 226Ra, or [(75 +/- 22.5)(4.7 +/- 0.47)-1] = 16 +/- 5 for a single, brief intake of either nuclide into blood.

  16. On the use of volumetric-modulated arc therapy for single-fraction thoracic vertebral metastases stereotactic body radiosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pokhrel, Damodar, E-mail: damodar.pokhrel@uky.edu; Sood, Sumit; McClinton, Christopher

    To retrospectively evaluate quality, efficiency, and delivery accuracy of volumetric-modulated arc therapy (VMAT) plans for single-fraction treatment of thoracic vertebral metastases using image-guided stereotactic body radiosurgery (SBRS) after RTOG 0631 dosimetric compliance criteria. After obtaining credentialing for MD Anderson spine phantom irradiation validation, 10 previously treated patients with thoracic vertebral metastases with noncoplanar hybrid arcs using 1 to 2 3D-conformal partial arcs plus 7 to 9 intensity-modulated radiation therapy beams were retrospectively re-optimized with VMAT using 3 full coplanar arcs. Tumors were located between T2 and T12. Contrast-enhanced T1/T2-weighted magnetic resonance images were coregistered with planning computed tomography and planningmore » target volumes (PTV) were between 14.4 and 230.1 cc (median = 38.0 cc). Prescription dose was 16 Gy in 1 fraction with 6 MV beams at Novalis-TX linear accelerator consisting of micro multileaf collimators. Each plan was assessed for target coverage using conformality index, the conformation number, the ratio of the volume receiving 50% of the prescription dose over PTV, R50%, homogeneity index (HI), and PTV-1600 coverage per RTOG 0631 requirements. Organs-at-risk doses were evaluated for maximum doses to spinal cord (D{sub 0.03} {sub cc}, D{sub 0.35} {sub cc}), partial spinal cord (D{sub 10%}), esophagus (D{sub 0.03} {sub cc} and D{sub 5} {sub cc}), heart (D{sub 0.03} {sub cc} and D{sub 15} {sub cc}), and lung (V{sub 5}, V{sub 10}, and maximum dose to 1000 cc of lung). Dose delivery efficiency and accuracy of each VMAT-SBRS plan were assessed using quality assurance (QA) plan on MapCHECK device. Total beam-on time was recorded during QA procedure, and a clinical gamma index (2%/2 mm and 3%/3 mm) was used to compare agreement between planned and measured doses. All 10 VMAT-SBRS plans met RTOG 0631 dosimetric requirements for PTV coverage. The plans demonstrated highly conformal and homogenous coverage of the vertebral PTV with mean HI, conformality index, conformation number, and R{sub 50%} values of 0.13 ± 0.03 (range: 0.09 to 0.18), 1.03 ± 0.04 (range: 0.98 to 1.09), 0.81 ± 0.06 (range: 0.72 to 0.89), and 4.2 ± 0.94 (range: 2.7 to 5.4), respectively. All 10 patients met protocol guidelines with maximum dose to spinal cord (average: 8.83 ± 1.9 Gy, range: 5.9 to 10.9 Gy); dose to 0.35 cc of spinal cord (average: 7.62 ± 1.7 Gy, range: 5.4 to 9.6 Gy); and dose to 10% of partial spinal cord (average 6.31 ± 1.5 Gy, range: 3.5 to 8.5 Gy) less than 14, 10, and 10 Gy, respectively. For all 10 patients, the maximum dose to esophagus (average: 9.41 ± 4.3 Gy, range: 1.5 to 14.9 Gy) and dose to 5 cc of esophagus (average: 7.43 ± 3.8 Gy, range: 1.1 to 11.8 Gy) were kept less than protocol requirements 16 Gy and 11.9 Gy, respectively. In a similar manner, all 10 patients met protocol compliance criteria with maximum dose to heart (average: 4.62 ± 3.5 Gy, range: 1.3 to 10.2 Gy) and dose to 15 cc of heart (average: 2.23 ± 1.8 Gy, range: 0.3 to 5.6 Gy) less than 22 and 16 Gy, respectively. The dose to the lung was retained much lower than protocol guidelines for all 10 patients. The total number of monitor units was, on average, 6919 ± 1187. The average beam-on time was 11.5 ± 2.0 minutes. The VMAT plans demonstrated dose delivery accuracy of 95.8 ± 0.7%, on average, for clinical gamma passing rate with 2%/2 mm criteria and 98.3 ± 0.8%, on average, with 3%/3 mm criteria. All VMAT-SBRS plans were considered clinically acceptable per RTOG 0631 dosimetric compliance criteria. VMAT planning provided highly conformal and homogenous dose distributions for the lower-dose vertebral PTV and the spinal cord as well as organs-at-risk such as esophagus, heart, and lung. Higher QA pass rates and shorter beam-on time suggest that VMAT-SBRS is a clinically feasible, fast, and effective treatment option for patients with thoracic vertebral metastases.« less

  17. FDG-PET Assessment of the Effect of Head and Neck Radiotherapy on Parotid Gland Glucose Metabolism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roach, Michael C.; Turkington, Timothy G.; Department of Biomedical Engineering, Duke University Medical Center, Duke University, Durham, NC

    Purpose: Functional imaging with [F-18]-fluorodeoxyglucose positron emission tomography (FDG-PET) provides the opportunity to define the physiology of the major salivary glands before and after radiation therapy. The goal of this retrospective study was to identify the radiation dose-response relationship of parotid gland glucose metabolism in patients with head and neck squamous cell carcinoma (HNSCC). Materials and Methods: Forty-nine adults with HNSCC were identified who had curative intent intensity-modulated radiation therapy (IMRT) and FDG-PET imaging before and after treatment. Using a graphical user interface, contours were delineated for the parotid glands on axial CT slices while all authors were blinded tomore » paired PET slices. Average and maximal standard uptake values (SUV) were measured within these anatomic regions. Changes in SUV and volume after radiation therapy were correlated with parotid gland dose-volume histograms from IMRT plans. Results: The average parotid gland volume was 30.7 mL and contracted 3.9 {+-} 1.9% with every increase of 10 Gy in mean dose (p = 0.04). However, within the first 3 months after treatment, there was a uniform reduction of 16.5% {+-} 7.3% regardless of dose. The average SUV{sub mean} of the glands was 1.63 {+-} 0.48 pretreatment and declined by 5.2% {+-} 2.5% for every increase of 10 Gy in mean dose (p = 0.04). The average SUV{sub max} was 4.07 {+-} 2.85 pretreatment and decreased in a sigmoid manner with mean dose. A threshold of 32 Gy for mean dose existed, after which SUV{sub max} declined rapidly. Conclusion: Radiation dose responses of the parotid glands can be measured by integrated CT/FDG-PET scans. Retrospective analysis showed sigmoidal declines in the maximum metabolism but linear declines in the average metabolism of the glands with dose. Future studies should correlate this decline in FDG uptake with saliva production to improve treatment planning.« less

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Small, Katherine; Kelly, Chris; Beldham-Collins, Rachael

    A comparative study was conducted comparing the difference between (1) conformal radiotherapy (CRT) to the whole breast with sequential boost excision cavity plans and (2) intensity-modulated radiation therapy (IMRT) to the whole breast with simultaneously integrated boost to the excision cavity. The computed tomography (CT) data sets of 25 breast cancer patients were used and the results analysed to determine if either planning method produced superior plans. CT data sets from 25 past breast cancer patients were planned using (1) CRT prescribed to 50 Gy in 25 fractions (Fx) to the whole-breast planning target volume (PTV) and 10 Gy inmore » 5Fx to the excision cavity and (2) IMRT prescribed to 60 Gy in 25Fx, with 60 Gy delivered to the excision cavity PTV and 50 Gy delivered to the whole-breast PTV, treated simultaneously. In total, 50 plans were created, with each plan evaluated by PTV coverage using conformity indices, plan maximum dose, lung dose, and heart maximum dose for patients with left-side lesions. CRT plans delivered the lowest plan maximum doses in 56% of cases (average CRT = 6314.34 cGy, IMRT = 6371.52 cGy). They also delivered the lowest mean lung dose in 68% of cases (average CRT = 1206.64 cGy, IMRT = 1288.37 cGy) and V20 in 88% of cases (average CRT = 20.03%, IMRT = 21.73%) and V30 doses in 92% of cases (average CRT = 16.82%, IMRT = 17.97%). IMRT created more conformal plans, using both conformity index and conformation number, in every instance, and lower heart maximum doses in 78.6% of cases (average CRT = 5295.26 cGy, IMRT = 5209.87 cGy). IMRT plans produced superior dose conformity and shorter treatment duration, but a slightly higher planning maximum and increased lung doses. IMRT plans are also faster to treat on a daily basis, with shorter fractionation.« less

  19. Survey of Occupational Noise Exposure in CF Personnel in Selected High-Risk Trades

    DTIC Science & Technology

    2003-11-01

    peak, maximum level , minimum level , average sound level , time weighted average, dose, projected 8-hour dose, and upper limit time were measured for...10 4.4.2 Maximum Sound Level ...11 4.4.3 Minimum Sound Level

  20. Dosimetric verification of lung cancer treatment using the CBCTs estimated from limited-angle on-board projections.

    PubMed

    Zhang, You; Yin, Fang-Fang; Ren, Lei

    2015-08-01

    Lung cancer treatment is susceptible to treatment errors caused by interfractional anatomical and respirational variations of the patient. On-board treatment dose verification is especially critical for the lung stereotactic body radiation therapy due to its high fractional dose. This study investigates the feasibility of using cone-beam (CB)CT images estimated by a motion modeling and free-form deformation (MM-FD) technique for on-board dose verification. Both digital and physical phantom studies were performed. Various interfractional variations featuring patient motion pattern change, tumor size change, and tumor average position change were simulated from planning CT to on-board images. The doses calculated on the planning CT (planned doses), the on-board CBCT estimated by MM-FD (MM-FD doses), and the on-board CBCT reconstructed by the conventional Feldkamp-Davis-Kress (FDK) algorithm (FDK doses) were compared to the on-board dose calculated on the "gold-standard" on-board images (gold-standard doses). The absolute deviations of minimum dose (ΔDmin), maximum dose (ΔDmax), and mean dose (ΔDmean), and the absolute deviations of prescription dose coverage (ΔV100%) were evaluated for the planning target volume (PTV). In addition, 4D on-board treatment dose accumulations were performed using 4D-CBCT images estimated by MM-FD in the physical phantom study. The accumulated doses were compared to those measured using optically stimulated luminescence (OSL) detectors and radiochromic films. Compared with the planned doses and the FDK doses, the MM-FD doses matched much better with the gold-standard doses. For the digital phantom study, the average (± standard deviation) ΔDmin, ΔDmax, ΔDmean, and ΔV100% (values normalized by the prescription dose or the total PTV) between the planned and the gold-standard PTV doses were 32.9% (±28.6%), 3.0% (±2.9%), 3.8% (±4.0%), and 15.4% (±12.4%), respectively. The corresponding values of FDK PTV doses were 1.6% (±1.9%), 1.2% (±0.6%), 2.2% (±0.8%), and 17.4% (±15.3%), respectively. In contrast, the corresponding values of MM-FD PTV doses were 0.3% (±0.2%), 0.9% (±0.6%), 0.6% (±0.4%), and 1.0% (±0.8%), respectively. Similarly, for the physical phantom study, the average ΔDmin, ΔDmax, ΔDmean, and ΔV100% of planned PTV doses were 38.1% (±30.8%), 3.5% (±5.1%), 3.0% (±2.6%), and 8.8% (±8.0%), respectively. The corresponding values of FDK PTV doses were 5.8% (±4.5%), 1.6% (±1.6%), 2.0% (±0.9%), and 9.3% (±10.5%), respectively. In contrast, the corresponding values of MM-FD PTV doses were 0.4% (±0.8%), 0.8% (±1.0%), 0.5% (±0.4%), and 0.8% (±0.8%), respectively. For the 4D dose accumulation study, the average (± standard deviation) absolute dose deviation (normalized by local doses) between the accumulated doses and the OSL measured doses was 3.3% (±2.7%). The average gamma index (3%/3 mm) between the accumulated doses and the radiochromic film measured doses was 94.5% (±2.5%). MM-FD estimated 4D-CBCT enables accurate on-board dose calculation and accumulation for lung radiation therapy. It can potentially be valuable for treatment quality assessment and adaptive radiation therapy.

  1. Population dose commitments due to radioactive releases from nuclear power plant sites in 1987

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1987. Fifty-year dose commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 70 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for reach of the sites is a histogram showing the fraction of the total population within 2 to 80 kmmore » around each site receiving various average dose commitments from the airborne pathways. The site average individual dose commitment from all pathways ranged from a low of 2 {times} 10{sup {minus}6} mrem to a high of 0.009 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites. However, licensee calculation of doses to the maximally exposed individual at some sites indicated values of up to approximately 100 times average individual doses (on the order of a few millirem per year). 2 refs., 2 figs., 7 tabs.« less

  2. Analysis of nodal coverage utilizing image guided radiation therapy for primary gynecologic tumor volumes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmed, Faisal; Loma Linda University Medical Center, Department of Radiation Oncology, Loma Linda, CA; Sarkar, Vikren

    Purpose: To evaluate radiation dose delivered to pelvic lymph nodes, if daily Image Guided Radiation Therapy (IGRT) was implemented with treatment shifts based on the primary site (primary clinical target volume [CTV]). Our secondary goal was to compare dosimetric coverage with patient outcomes. Materials and methods: A total of 10 female patients with gynecologic malignancies were evaluated retrospectively after completion of definitive intensity-modulated radiation therapy (IMRT) to their pelvic lymph nodes and primary tumor site. IGRT consisted of daily kilovoltage computed tomography (CT)-on-rails imaging fused with initial planning scans for position verification. The initial plan was created using Varian's Eclipsemore » treatment planning software. Patients were treated with a median radiation dose of 45 Gy (range: 37.5 to 50 Gy) to the primary volume and 45 Gy (range: 45 to 64.8 Gy) to nodal structures. One IGRT scan per week was randomly selected from each patient's treatment course and re-planned on the Eclipse treatment planning station. CTVs were recreated by fusion on the IGRT image series, and the patient's treatment plan was applied to the new image set to calculate delivered dose. We evaluated the minimum, maximum, and 95% dose coverage for primary and nodal structures. Reconstructed primary tumor volumes were recreated within 4.7% of initial planning volume (0.9% to 8.6%), and reconstructed nodal volumes were recreated to within 2.9% of initial planning volume (0.01% to 5.5%). Results: Dosimetric parameters averaged less than 10% (range: 1% to 9%) of the original planned dose (45 Gy) for primary and nodal volumes on all patients (n = 10). For all patients, ≥99.3% of the primary tumor volume received ≥ 95% the prescribed dose (V95%) and the average minimum dose was 96.1% of the prescribed dose. In evaluating nodal CTV coverage, ≥ 99.8% of the volume received ≥ 95% the prescribed dose and the average minimum dose was 93%. In evaluating individual IGRT sessions, we found that 6 patients had an estimated minimal nodal CTV dose less than 90% (range: 78 to 99%) of that planned. With a median follow-up of 42.5 months, 2 patients experienced systemic disease progression at an average of 19.6 months. One patient was found to have a local or regional failure with an average follow-up of 42 months. Conclusion: Using only 3 dimensional IGRT corrections in gynecological radiation allows excellent coverage of the primary target volume and good average nodal CTV coverage. If IGRT corrections are based on alignment to the primary tumor volume, and is only able to be corrected in 3 degrees, this can create situations in which nodal volumes may be under dosed. Utilizing multiple IGRT sessions appears to average out dose discrepancies over the course of treatment. The implication of underdosing in a single IGRT session needs further evaluation in future studies. Based on the concern of minimum dose to a nodal target volume, these findings may signal caution when using IGRT and IMRT in gynecological radiation patients. Possible techniques to overcome this situation may include averaging shifts between tumor and nodal volume, use of a treatment couch with 6° of freedom, deformable registration, or adaptive planning.« less

  3. Radionuclide concentrations in soil and lifetime cancer risk due to gamma radioactivity in Kirklareli, Turkey.

    PubMed

    Taskin, H; Karavus, M; Ay, P; Topuzoglu, A; Hidiroglu, S; Karahan, G

    2009-01-01

    The objective of this study is to evaluate and map soil radionuclides' activity concentrations and environmental outdoor gamma dose rates (terrestrial and cosmic) in Kirklareli, Turkey. The excess lifetime cancer risks are also calculated. Outdoor gamma dose rates were determined in 230 sampling stations and soil samples were taken from 177 locations. The coordinates of the readings were determined by the Global Positioning System (GPS). The outdoor gamma dose rates were determined by Eberline smart portable device (ESP-2) and measurements were taken in air for two minutes at 1m from the ground. The average outdoor gamma dose rate was 118+/-34nGyh(-1). Annual effective gamma dose of Kirklareli was 144microSv and the excess lifetime cancer risk of 5.0x10(-4). Soil samples were analyzed by gamma spectroscopy. The average 226Ra, 238U, 232Th, 137Cs, and 40K activities were 37+/-18Bqkg(-1), 28+/-13Bqkg(-1), 40+/-18Bqkg(-1), 8+/-5Bqkg(-1) and 667+/-281Bqkg(-1), respectively. The average soil radionuclides' concentrations of Kirklareli were within the worldwide range although some extreme values had been determined. Annual effective gamma doses and the excess lifetime risks of cancer were higher than the world's average.

  4. Systematic influences of gamma-ray spectrometry data near the decision threshold for radioactivity measurements in the environment.

    PubMed

    Zorko, Benjamin; Korun, Matjaž; Mora Canadas, Juan Carlos; Nicoulaud-Gouin, Valerie; Chyly, Pavol; Blixt Buhr, Anna Maria; Lager, Charlotte; Aquilonius, Karin; Krajewski, Pawel

    2016-07-01

    Several methods for reporting outcomes of gamma-ray spectrometric measurements of environmental samples for dose calculations are presented and discussed. The measurement outcomes can be reported as primary measurement results, primary measurement results modified according to the quantification limit, best estimates obtained by the Bayesian posterior (ISO 11929), best estimates obtained by the probability density distribution resembling shifting, and the procedure recommended by the European Commission (EC). The annual dose is calculated from the arithmetic average using any of these five procedures. It was shown that the primary measurement results modified according to the quantification limit could lead to an underestimation of the annual dose. On the other hand the best estimates lead to an overestimation of the annual dose. The annual doses calculated from the measurement outcomes obtained according to the EC's recommended procedure, which does not cope with the uncertainties, fluctuate between an under- and overestimation, depending on the frequency of the measurement results that are larger than the limit of detection. In the extreme case, when no measurement results above the detection limit occur, the average over primary measurement results modified according to the quantification limit underestimates the average over primary measurement results for about 80%. The average over best estimates calculated according the procedure resembling shifting overestimates the average over primary measurement results for 35%, the average obtained by the Bayesian posterior for 85% and the treatment according to the EC recommendation for 89%. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Comparison of TID Effects in Space-Like Variable Dose Rates and Constant Dose Rates

    NASA Technical Reports Server (NTRS)

    Harris, Richard D.; McClure, Steven S.; Rax, Bernard G.; Evans, Robin W.; Jun, Insoo

    2008-01-01

    The degradation of the LM193 dual voltage comparator has been studied at different TID dose rate profiles, including several different constant dose rates and a variable dose rate that simulates the behavior of a solar flare. A comparison of results following constant dose rate vs. variable dose rates is made to explore how well the constant dose rates used for typical part testing predict the performance during a simulated space-like mission. Testing at a constant dose rate equal to the lowest dose rate seen during the simulated flare provides an extremely conservative estimate of the overall amount of degradation. A constant dose rate equal to the average dose rate is also more conservative than the variable rate. It appears that, for this part, weighting the dose rates by the amount of total dose received at each rate (rather than the amount of time at each dose rate) results in an average rate that produces an amount of degradation that is a reasonable approximation to that received by the variable rate.

  6. Pap test

    MedlinePlus

    ... Pap; Low-grade Pap; High-grade Pap; Carcinoma in situ - Pap; CIS - Pap; ASCUS - Pap; Atypical glandular cells - ... to cervical cancer is greater with HSIL. CARCINOMA IN SITU (CIS): This result most often means the abnormal ...

  7. Pediatric Chest and Abdominopelvic CT: Organ Dose Estimation Based on 42 Patient Models

    PubMed Central

    Tian, Xiaoyu; Li, Xiang; Segars, W. Paul; Paulson, Erik K.; Frush, Donald P.

    2014-01-01

    Purpose To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. Materials and Methods The institutional review board approved this HIPAA–compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0–16 years; weight range, 2–80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDIvol). The relationships between CTDIvol-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. Results For organs within the image coverage, CTDIvol-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R2 > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%–32%) mainly because of the effect of overranging. Conclusion It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDIvol. These CTDIvol-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice. © RSNA, 2013 PMID:24126364

  8. Endocytoscopic findings of lymphomas of the stomach

    PubMed Central

    2013-01-01

    Background The gastric lesions of various lymphomas were observed at the cellular level using endocytoscopy. Methods Endocytoscopy and magnifying endoscopy with narrow band imaging (NBI) were performed in 17 patients with lymphomas of the stomach. The lesions consisted of 7 with low-grade mucosa-associated lymphoid tissue (MALT), 5 with gastric involvement by adult T-cell leukemia/lymphoma (ATLL), 4 with diffuse large B-cell lymphoma (DLBCL), and 1 with peripheral T-cell lymphoma. Results On conventional endoscopy, 9 were classified as having superficial spreading type, 7 were mass-forming type, and 1 was diffuse infiltrating type. Anti-H. pylori treatment was given in the 7 MALT lymphoma cases. NBI magnification endoscopy invariably showed dilatation or ballooning and destruction of gastric pits and elongation and distortion in microvessels. Endocytoscopy showed mucosal aggregation of interstitial cellular elements in almost all gastric lymphoma cases. The nuclear diversity in size and configuration was exclusively seen in gastric lymphomas other than MALT lymphoma, whereas the nuclei of MALT lymphoma cells were regular and small to moderate in size. Inter-glandular infiltration by lymphomatous cell elements was frequently observed in MALT lymphoma and DLBCL, but it was uncommon in peripheral gastric T-cell malignancies. Endocytoscopy could identify the disease-specific histology, the lymphoepithelial origin, as inter-glandular infiltration of cellular components in MALT lymphoma and the possibly related DLBCL cases. Complete regression (CR) was observed in 2 of the 7 MALT lymphoma patients. In the 2 patients with CR who underwent repeat endocytoscopy, the ultra-high magnification abnormalities returned to normal, while they were unchanged in those without tumor regression. Conclusions On endocytoscopy, intra-glandular aggregation of cellular components was invariably identified in lymphomas of the stomach. Nuclear regularity in size and configuration may indicate the cytological grade, differentiating the indolent low-grade from aggressive lymphoproliferative diseases. The inter-glandular infiltration seen on endocytoscopy can indicate the lymphoepithelial lesions seen in MALT lymphoma and related DLBCL. Endocytoscopy would be applicable for virtual histopathological diagnosis of different lymphoproliferative disorders and their clinical assessment during ongoing endoscopy. PMID:24369830

  9. Usefulness of p16ink4a, ProEX C, and Ki-67 for the diagnosis of glandular dysplasia and adenocarcinoma of the cervix uteri.

    PubMed

    Negri, Giovanni; Bellisano, Giulia; Carico, Elisabetta; Faa, Gavino; Kasal, Armin; Antoniazzi, Sonia; Egarter-Vigl, Eduard; Piccin, Andrea; Dalla Palma, Paolo; Vittadello, Fabio

    2011-07-01

    Although the diagnostic criteria of in-situ and invasive adenocarcinomas of the cervix uteri are well established, the differentiation from benign mimics may be difficult and the morphologic features of the precursors of endocervical adenocarcinoma are still debated. In this study, we evaluated the usefulness of p16ink4a (p16), ProEX C, and Ki-67 for the diagnosis of endocervical adenocarcinoma and its precursors. Immunohistochemistry with p16, ProEX C, and Ki-67 was performed in 82 glandular lesions including 15 invasive adenocarcinomas, 29 adenocarcinomas in situ (AIS), 22 non-neoplastic samples, and 16 cases of glandular dysplasia (GD), which showed significant nuclear abnormalities but did not meet the diagnostic criteria for AIS. The immunohistochemical expression pattern was scored according to the percentage of the stained cells (0, 1+, 2+, and 3+ when 0% to 5%, 6% to 25%, 26% to 50%, and more than 50% of the cells were stained, respectively) and was evaluated for each antibody. p16 was at least focally expressed (1+ or more) in 14 of 15 invasive adenocarcinomas, in all AIS and in 7 negative samples. ProEX C and Ki-67 both scored 1+ or more in all adenocarcinomas and AIS and in 8 and 6 negative samples, respectively. Of the GD 15, 14, and 15 expressed p16, ProEX C, and Ki-67, respectively. The score differences between neoplastic and non-neoplastic samples were highly significant for each marker (P<0.001); however, the score distribution by marker differed significantly only in GD (P=0.006) in which, compared with the other markers, p16 showed more often a 3+ pattern. Our study shows that p16, Ki-67, and ProEX C may be helpful for the diagnosis of glandular lesions of the cervix uteri and may also improve the diagnostic accuracy of endocervical GD. In particularly problematic cases, the combination of p16 and a proliferation marker can provide additional help for the interpretation of these lesions.

  10. [Markers of stromal invasion during background and precancerous changes of the glandular epithelium and in adenocarcinoma of the cervix uteri].

    PubMed

    Danilova, N V; Andreeva, Iu Iu; Zavalishina, L É; Mal'kov, P G

    2012-01-01

    It is very difficult to identify stromal invasion when the glandular epithelium of the cervix uteri is involved. It is necessary to draw a clear distinction between its glandular structures and adenocarcinoma in situ, involving the preexisting crypts and invasive glands. An attempt was made to assess the possibilities of using as markers of invasion the following stromal proteins and adhesion molecules: CD44, E-cadherin, beta-catenin, tenascin, and laminin. Fifty-three cases of benign glandular changes, 66 cases of dysplasias and adenocarcinomas in situ, and 47 cases of invasive adenocarcinoma were examined. An immunohistochemical study was performed according to the standard protocol using the antibodies to CD44, laminin, tenascin, E-cadherin, and beta-catenin and a semiquantitative assessment of results was made. CD44 was found to be redistributed from the cells to the tumor stroma. CD44 was not detected in the stroma surrounding the intact glands, so were benign epithelial changes. In the tumor environment, there was, on the contrary, a reaction with CD44 in 74.5% of invasive adenocarcinomas cases (p < 0.05). The expression of tenascin in the invasive adenocarcinomas and around the foci of early stromal invasion significantly exceeded that in the stroma around the intact glands and dysplastic changes (p < 0.05). All the study groups showed a membrane reaction with E-cadherin and beta-catenin, which probably suggested that changes were absent in the Wnt signaling pathway. In 70.2% of invasive adenocarcinomas, laminin demonstrated a significant cytoplasmic expression in 5-30% of the tumor cells predominantly located along the tumor invasion area or in the deepest tumor complexes (p > 0.05). CD44 and tenascin are of great diagnostic value in examining invasive and microinvasive adenocarcinomas of the cervix uteri. E-cadherin and beta-catenin are of no diagnostic value in the study groups of pathological processes. Laminin is a potential marker of stromal invasion; however, its expression calls for further investigation.

  11. Immunolocalization of adipocytes and prostaglandin E2 and its four receptor proteins EP1, EP2, EP3, and EP4 in the caprine cervix during spontaneous term labor.

    PubMed

    Gu, Guosheng; Gao, Qian; Yuan, Xuejun; Huang, Libo; Ge, Lijiang

    2012-05-01

    The mechanisms of cervical ripening and dilation in mammals remain obscure. Information is lacking about the localization of prostaglandin E(2) (PGE(2))-producing cells and PGE(2) receptors (EP) in intrapartum cervix and whether cervical dilation at parturition is an active process. To reveal these mechanisms, immunolocalization of EP1-EP4 (official gene symbols PTGER1-PTGER4) and PGE(2)-producing cells in caprine cervix during nonpregnancy, pregnancy, and parturition was assayed by immunohistochemistry (IHC); the mRNA expression levels of PTGS2, PTGER2 (EP2), and PTGER4 (EP4) were determined using quantitative PCR; and the existence of adipocytes in the cervix at various stages was demonstrated with Oil Red O staining and IHC of perilipin A. The results suggested that in intrapartum caprine cervix staining of the PGE(2) was observed in the overall tissues, for example, blood vessels, canal or glandular epithelia, serosa, circular and longitudinal muscles, and stroma in addition to adipocytes; EP2 was detectable in all the tissues other than glandular epithelia; EP4 was strongly expressed in all the tissues other than serosa; EP1 was detected mainly in arterioles and canal or glandular epithelia; and EP3 was poorly expressed only in stroma, canal epithelia, and circular muscles. Little or no expression of EP2, EP3, and EP4 as well as PGE(2) in all cervical tissues was observed during nonpregnancy and pregnancy except for the strong expression of EP1 in canal or glandular epithelia during pregnancy. The mRNA expression levels of PTGS2, PTGER2, and PTGER4 were significantly higher in intrapartum than nonpregnant and midpregnant cervices (P < 0.01). Adipocytes appear only in the intrapartum cervix. These results support the concept that PGE(2) modulates specific functions in various anatomical structures of the caprine cervix at labor and the appearance of adipocytes at labor is likely related to caprine cervical dilation.

  12. Effect of sea buckthorn berries and pulp in a liquid emulsion on gastric ulcer scores and gastric juice pH in horses.

    PubMed

    Huff, N K; Auer, A D; Garza, F; Keowen, M L; Kearney, M T; McMullin, R B; Andrews, F M

    2012-01-01

    Sea buckthorn berries (Hippophae rhamnoides) are rich in vitamin C and E, carotenoids, flavonoids, fatty acids, plant sterols, lignans, and minerals. A feed supplement containing sea buckthorn berries might have efficacy in treatment and prevention of gastric ulcers in horses. To test the efficacy of a commercially available formulation of sea buckthorn berries and pulp (SeaBuck SBT Gastro-Plus) for treatment and prevention of gastric ulcers in stall-confined horses. Eight Thoroughbred and Thoroughbred-cross horses (3-10 years of age, 5 geldings and 3 mares, 380-600 kg body weight). This study was a 2-period crossover in which all horses received no treatment (untreated controls; n = 8) and treatment (SeaBuckSBT Gastro-Plus, 4 ounces [35.6 g berries and pulp], twice daily; n = 8) mixed with a pelleted complete feed (18% crude fiber; 9% starch; 14% crude protein). Horses were treated for 4 weeks followed by a 1-week (d28-d35) alternating feed-deprivation period to induce or worsen existing ulcers. Gastroscopic examinations were performed on days 0, 28, and 35. Gastric juice pH was measured and gastric ulcer number and severity scores were assigned by a masked investigator. Mean nonglandular gastric ulcer scores significantly (P < .05) increased in all horses after day 28, as a result of intermittent feed deprivation. Mean nonglandular gastric ulcer number (P = .84) and severity (P = .51) were not significantly different between SBT-treated and untreated control horses. However, mean glandular ulcer number (P = .02) and glandular ulcer severity (P = .02) were significantly lower in the SBT-treated horses compared with the untreated control at week 5. SeaBuck SBT Gastro-Plus liquid fed to horses did not show efficacy in treatment or prevention of naturally occurring nonglandular ulcers in horses; however, glandular ulcer scores were significantly lower in SBT-treated horses after feed deprivation. Thus, SBT might have efficacy in prevention of glandular ulcers in horses housed in stalls and undergoing intermittent feeding. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  13. Nasolacrimal duct obstruction following radioactive iodine 131 therapy in differentiated thyroid cancers: review of 19 cases.

    PubMed

    Al-Qahtani, Khalid Hussain; Al Asiri, Mushabbab; Tunio, Mutahir A; Aljohani, Naji J; Bayoumi, Yasser; Munir, Iqbal; AlAyoubi, Ayman

    2014-01-01

    Radioactive iodine 131 ((131)I) therapy has long been used in the treatment of differentiated thyroid cancers (DTC). While salivary and lacrimal glandular complications secondary to (131)I therapy are well documented, there is little in the literature addressing nasolacrimal duct obstruction (NLDO). We aimed to evaluate the frequency of (131)I therapy-acquired NLDO, its correlation to (131)I therapy doses, and the surgical treatment outcome of this rare side effect. From 2000-2012, a retrospective review of 864 among 1,192 patients with confirmed DTC who were treated with (131)I therapy was performed to examine the frequency of NLDO, its causative factors, as well as imaging, surgical intervention, and outcomes. Nineteen (2.2%) patients were identified with NLDO. The mean age was 51.9±10.5 years (range: 39-72 years). Fifteen (78.9%) were female and four were male (21.1%). The mean individual (131)I doses were 311.1±169.3 millicurie (mCi) (range: 150-600 mCi). The mean duration between the date of (131)I therapy and the occurrence of NLDO was 11.6±4.1 months (range: 6.5-20). Fourteen (73.7%) patients had bilateral epiphora. Computed tomography dacryography allowed for the detection of all NLDO. Eighteen (94.7%) patients underwent dacryocystorhinostomy. Complete recovery was obtained in 14 (73.7%) patients. Age >45 years and (131)I therapy doses >150 mCi were significantly correlated with NLDO (P=0.02 and P=0.03, respectively). NLDO is an underestimated complication of (131)I therapy in DTC patients. Clinicians should be aware of this rare complication for prompt intervention.

  14. Thyroid disorders in patients treated with radiotherapy for head-and-neck cancer: A retrospective analysis of seventy-three patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alterio, Daniela; Jereczek-Fossa, Barbara Alicja; University of Milan, Milan

    2007-01-01

    Purpose: To evaluate the incidence of thyroid disorders and dose distribution to the thyroid in patients treated with radiotherapy for head-and-neck carcinomas. Methods and Materials: A retrospective evaluation of data from 73 patients treated for head-and-neck cancers in our department was performed. Thyroid function was evaluated mainly by the measurement of thyrotropin (thyroid stimulating hormone [TSH]). A retrospective analysis of treatment plans was performed for 57 patients. Percentages of thyroid glandular volume absorbing 10, 30, and 50 Gy (V10, V30, and V50 respectively) were considered for statistical analysis. Results: A majority of patients (61%) had a normal thyroid function whereasmore » 19 patients (26%) had hypothyroidism. Mean thyroid volume was 30.39 cc. Point 3 (located at isthmus) absorbed lower doses compared with other points (p < 0.0001). Median values of V10, V30, and V50 were 92% (range, 57-100%), 75% (range, 28.5-100%), and 35% (range, 3-83%) respectively. Gender was associated with toxicity (presence of any kind of thyroid disorders) (p < 0.05), with females displaying higher levels of TSHr (relative TSH = patient's value/maximum value of the laboratory range) (p = 0.0005) and smaller thyroid volume (p 0.0012) compared with male population. TSHr values were associated with thyroid volume, and the presence of midline shielding block in the anterior field was associated with relative free thyroxine (FT4r = patient's value/maximum value of the laboratory range) values. Conclusions: Gender and thyroid volume seem to play an important role in the occurrence of thyroid toxicity, but further studies on dose-effect relationship for radiotherapy-induced thyroid toxicity are needed.« less

  15. Current status of radiological protection at nuclear power stations in Japan.

    PubMed

    Suzuki, Akira; Hori, Shunsuke

    2011-07-01

    The radiation dose to workers at nuclear power stations (NPSs) in Japan was drastically reduced between the late-1970s and the early-1990s by continuous dose-reduction programmes. The total collective dose of radiation workers in FY 2008 was 84.04 person Sv, while the average collective dose was 1.5 person Sv per reactor. The average annual individual dose was 1.1 mSv and the maximum annual individual dose was 19.5 mSv. These values are sufficiently lower than the regulatory dose limits. Radioactive effluent released from NPSs is already so trivial that additional protective measures will not be necessary. Experience in radiation protection at NPSs has been accumulated over 40 y and will be very useful in establishing a rational radiation control system in the future.

  16. Proxy-based reconstruction of erythemal UV doses over Estonia for 1955 2004

    NASA Astrophysics Data System (ADS)

    Eerme, K.; Veismann, U.; Lätt, S.

    2006-08-01

    A proxy-based reconstruction of the erythemally-weighted UV doses for 1955-2004 has been performed for the Tartu-Tõravere Meteorological Station (58°16' N, 26°28' E, 70 m a.s.l.) site. The pyrheliometer-measured daily sum of direct irradiance on partly cloudy and clear days, and the pyranometer-measured daily sum of global irradiance on overcast days were used as the cloudiness influence related proxies. The TOMS ozone data have been used for detecting the daily deviations from the climatic value (averaged annual cycle). In 1998-2004, the biases between the measured and reconstructed daily doses in 55.5% of the cases were within ±10% and in 83.5% of the cases within ±20%, on average. In the summer half-year these amounts were 62% and 88%, respectively. In most years the results for longer intervals did not differ significantly, if no correction was made for the daily deviations of total ozone from its climatic value. The annual and summer half-yearly erythemal doses (contributing, on average, 89% of the annual value) agreed within ±2%, except for the years after major volcanic eruptions and one extremely fine weather year (2002). Using the daily relative sunshine duration as a proxy without detailed correction for atmospheric turbidity results in biases of 2-4% in the summer half-yearly dose in the years after major volcanic eruptions and a few other years of high atmospheric turbidity. The year-to-year variations of the summer half-yearly erythemal dose in 1955-2004 were found to be within 92-111% relative to their average value. Exclusion of eight extreme years reduces this range for the remaining to 95-105.5%. Due to the quasi-periodic alternation of wet and dry periods, the interval of cloudy summers 1976-1993 regularly manifests summer half-yearly erythemal dose values lower than the 1955-2004 average. Since 1996/1997 midwinters have been darker than on average.

  17. Determination of prescription dose for Cs-131 permanent implants using the BED formalism including resensitization correction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, Wei, E-mail: wei.luo@uky.edu; Molloy, Janelle; Aryal, Prakash

    2014-02-15

    Purpose: The current widely used biological equivalent dose (BED) formalism for permanent implants is based on the linear-quadratic model that includes cell repair and repopulation but not resensitization (redistribution and reoxygenation). The authors propose a BED formalism that includes all the four biological effects (4Rs), and the authors propose how it can be used to calculate appropriate prescription doses for permanent implants with Cs-131. Methods: A resensitization correction was added to the BED calculation for permanent implants to account for 4Rs. Using the same BED, the prescription doses with Au-198, I-125, and Pd-103 were converted to the isoeffective Cs-131 prescriptionmore » doses. The conversion factor F, ratio of the Cs-131 dose to the equivalent dose with the other reference isotope (F{sub r}: with resensitization, F{sub n}: without resensitization), was thus derived and used for actual prescription. Different values of biological parameters such as α, β, and relative biological effectiveness for different types of tumors were used for the calculation. Results: Prescription doses with I-125, Pd-103, and Au-198 ranging from 10 to 160 Gy were converted into prescription doses with Cs-131. The difference in dose conversion factors with (F{sub r}) and without (F{sub n}) resensitization was significant but varied with different isotopes and different types of tumors. The conversion factors also varied with different doses. For I-125, the average values of F{sub r}/F{sub n} were 0.51/0.46, for fast growing tumors, and 0.88/0.77 for slow growing tumors. For Pd-103, the average values of F{sub r}/F{sub n} were 1.25/1.15 for fast growing tumors, and 1.28/1.22 for slow growing tumors. For Au-198, the average values of F{sub r}/F{sub n} were 1.08/1.25 for fast growing tumors, and 1.00/1.06 for slow growing tumors. Using the biological parameters for the HeLa/C4-I cells, the averaged value of F{sub r} was 1.07/1.11 (rounded to 1.1), and the averaged value of F{sub n} was 1.75/1.18. F{sub r} of 1.1 has been applied to gynecological cancer implants with expected acute reactions and outcomes as expected based on extensive experience with permanent implants. The calculation also gave the average Cs-131 dose of 126 Gy converted from the I-125 dose of 144 Gy for prostate implants. Conclusions: Inclusion of an allowance for resensitization led to significant dose corrections for Cs-131 permanent implants, and should be applied to prescription dose calculation. The adjustment of the Cs-131 prescription doses with resensitization correction for gynecological permanent implants was consistent with clinical experience and observations. However, the Cs-131 prescription doses converted from other implant doses can be further adjusted based on new experimental results, clinical observations, and clinical outcomes.« less

  18. Determination of prescription dose for Cs-131 permanent implants using the BED formalism including resensitization correction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, Wei, E-mail: wei.luo@uky.edu; Molloy, Janelle; Aryal, Prakash

    Purpose: The current widely used biological equivalent dose (BED) formalism for permanent implants is based on the linear-quadratic model that includes cell repair and repopulation but not resensitization (redistribution and reoxygenation). The authors propose a BED formalism that includes all the four biological effects (4Rs), and the authors propose how it can be used to calculate appropriate prescription doses for permanent implants with Cs-131. Methods: A resensitization correction was added to the BED calculation for permanent implants to account for 4Rs. Using the same BED, the prescription doses with Au-198, I-125, and Pd-103 were converted to the isoeffective Cs-131 prescriptionmore » doses. The conversion factor F, ratio of the Cs-131 dose to the equivalent dose with the other reference isotope (F{sub r}: with resensitization, F{sub n}: without resensitization), was thus derived and used for actual prescription. Different values of biological parameters such as α, β, and relative biological effectiveness for different types of tumors were used for the calculation. Results: Prescription doses with I-125, Pd-103, and Au-198 ranging from 10 to 160 Gy were converted into prescription doses with Cs-131. The difference in dose conversion factors with (F{sub r}) and without (F{sub n}) resensitization was significant but varied with different isotopes and different types of tumors. The conversion factors also varied with different doses. For I-125, the average values of F{sub r}/F{sub n} were 0.51/0.46, for fast growing tumors, and 0.88/0.77 for slow growing tumors. For Pd-103, the average values of F{sub r}/F{sub n} were 1.25/1.15 for fast growing tumors, and 1.28/1.22 for slow growing tumors. For Au-198, the average values of F{sub r}/F{sub n} were 1.08/1.25 for fast growing tumors, and 1.00/1.06 for slow growing tumors. Using the biological parameters for the HeLa/C4-I cells, the averaged value of F{sub r} was 1.07/1.11 (rounded to 1.1), and the averaged value of F{sub n} was 1.75/1.18. F{sub r} of 1.1 has been applied to gynecological cancer implants with expected acute reactions and outcomes as expected based on extensive experience with permanent implants. The calculation also gave the average Cs-131 dose of 126 Gy converted from the I-125 dose of 144 Gy for prostate implants. Conclusions: Inclusion of an allowance for resensitization led to significant dose corrections for Cs-131 permanent implants, and should be applied to prescription dose calculation. The adjustment of the Cs-131 prescription doses with resensitization correction for gynecological permanent implants was consistent with clinical experience and observations. However, the Cs-131 prescription doses converted from other implant doses can be further adjusted based on new experimental results, clinical observations, and clinical outcomes.« less

  19. Carcinogenicity of antioxidants BHA, caffeic acid, sesamol, 4-methoxyphenol and catechol at low doses, either alone or in combination, and modulation of their effects in a rat medium-term multi-organ carcinogenesis model.

    PubMed

    Hirose, M; Takesada, Y; Tanaka, H; Tamano, S; Kato, T; Shirai, T

    1998-01-01

    The carcinogenicity of low dietary levels of the antioxidants butylated hydroxyanisole (BHA), caffeic acid, sesamol, 4-methoxyphenol (4-MP) and catechol, known to target the forestomach or glandular stomach, were examined alone or in combination in a 2-year long-term experiment and their modifying effects assessed in a medium-term multiorgan model. In the carcinogenicity study, groups of 30-31 male F344 rats were treated with 0.4% BHA, 0.4% caffeic acid, 0.4% sesamol, 0.4% 4-MP and 0.16% catechol either alone or in combination for up to 104 weeks and then killed. In the medium-term multi-organ model, groups of 10 to 15 male F344 rats were given diethylnitrosamine (DEN), N-methylnitrosourea (MNU), 1,2-dimethylhydrazine (DMH), N-butyl-N-(4-hydroxybutyl)nitrosamine (BBN) and 2,2'-dihydroxy-di-n-propylnitrosamine (DHPN) for a total multiple initiation period of 4 weeks (DMBDD treatment). BHA, caffeic acid, sesamol and 4-MP, each at doses of 0.4% or 0.08%, and catechol at doses of 0.16% or 0.032% were administered in the diet either alone or in combination after completion of the initiation regimen. All surviving animals were killed at the end of week 28, and major organs were examined histopathologically. In the carcinogenicity study, slightly increased incidences of forestomach papillomas were found in the sesamol- (15.8%), caffeic acid- (14.8%), catechol- (3%) and 4-MP- (11.5%) treated groups as compared with basal diet (0%), and a significant increase was observed with the five antioxidants in combination (42.9%, P < 0.001). In a medium-term multiorgan carcinogenesis model, incidences of forestomach papillomas and/or carcinomas were increased in each high dose group, but additive or synergistic effects were not found in the combination group. In the low dose case, the incidence of forestomach papillomas was significantly increased only in the combination group. With regard to other organs, the incidence of colon tumors was significantly decreased only in the high dose combination group. The results indicate that even at low dose levels phenolic compounds can exert additive/synergistic effect on carcinogenesis.

  20. Cervical Dysplasia: Is It Cancer?

    MedlinePlus

    ... showed cervical dysplasia. What does that mean? Is it cancer? Answers from Shannon K. Laughlin-Tommaso, M. ... or glandular cells. Dysplasia could go away on its own. Or, rarely, it could develop into cancer. ...

  1. TU-F-17A-08: The Relative Accuracy of 4D Dose Accumulation for Lung Radiotherapy Using Rigid Dose Projection Versus Dose Recalculation On Every Breathing Phase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamb, J; Lee, C; Tee, S

    2014-06-15

    Purpose: To investigate the accuracy of 4D dose accumulation using projection of dose calculated on the end-exhalation, mid-ventilation, or average intensity breathing phase CT scan, versus dose accumulation performed using full Monte Carlo dose recalculation on every breathing phase. Methods: Radiotherapy plans were analyzed for 10 patients with stage I-II lung cancer planned using 4D-CT. SBRT plans were optimized using the dose calculated by a commercially-available Monte Carlo algorithm on the end-exhalation 4D-CT phase. 4D dose accumulations using deformable registration were performed with a commercially available tool that projected the planned dose onto every breathing phase without recalculation, as wellmore » as with a Monte Carlo recalculation of the dose on all breathing phases. The 3D planned dose (3D-EX), the 3D dose calculated on the average intensity image (3D-AVE), and the 4D accumulations of the dose calculated on the end-exhalation phase CT (4D-PR-EX), the mid-ventilation phase CT (4D-PR-MID), and the average intensity image (4D-PR-AVE), respectively, were compared against the accumulation of the Monte Carlo dose recalculated on every phase. Plan evaluation metrics relating to target volumes and critical structures relevant for lung SBRT were analyzed. Results: Plan evaluation metrics tabulated using 4D-PR-EX, 4D-PR-MID, and 4D-PR-AVE differed from those tabulated using Monte Carlo recalculation on every phase by an average of 0.14±0.70 Gy, - 0.11±0.51 Gy, and 0.00±0.62 Gy, respectively. Deviations of between 8 and 13 Gy were observed between the 4D-MC calculations and both 3D methods for the proximal bronchial trees of 3 patients. Conclusions: 4D dose accumulation using projection without re-calculation may be sufficiently accurate compared to 4D dose accumulated from Monte Carlo recalculation on every phase, depending on institutional protocols. Use of 4D dose accumulation should be considered when evaluating normal tissue complication probabilities as well as in clinical situations where target volumes are directly inferior to mobile critical structures.« less

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, Bria M.; Brady, Samuel L., E-mail: samuel.brady@stjude.org; Kaufman, Robert A.

    Purpose: To investigate the correlation of size-specific dose estimate (SSDE) with absorbed organ dose, and to develop a simple methodology for estimating patient organ dose in a pediatric population (5–55 kg). Methods: Four physical anthropomorphic phantoms representing a range of pediatric body habitus were scanned with metal oxide semiconductor field effect transistor (MOSFET) dosimeters placed at 23 organ locations to determine absolute organ dose. Phantom absolute organ dose was divided by phantom SSDE to determine correlation between organ dose and SSDE. Organ dose correlation factors (CF{sub SSDE}{sup organ}) were then multiplied by patient-specific SSDE to estimate patient organ dose. Themore » CF{sub SSDE}{sup organ} were used to retrospectively estimate individual organ doses from 352 chest and 241 abdominopelvic pediatric CT examinations, where mean patient weight was 22 kg ± 15 (range 5–55 kg), and mean patient age was 6 yrs ± 5 (range 4 months to 23 yrs). Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm; thus, showing appropriate scalability of the phantoms across the entire pediatric population in this study. IndividualCF{sub SSDE}{sup organ} were determined for a total of 23 organs in the chest and abdominopelvic region across nine weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7–1.4) and abdominopelvic region (average 0.9; range 0.7–1.3) was near unity. For organ/tissue that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1–0.4) for both the chest and abdominopelvic regions, respectively. A means to estimate patient organ dose was demonstrated. Calculated patient organ dose, using patient SSDE and CF{sub SSDE}{sup organ}, was compared to previously published pediatric patient doses that accounted for patient size in their dose calculation, and was found to agree in the chest to better than an average of 5% (27.6/26.2) and in the abdominopelvic region to better than 2% (73.4/75.0). Conclusions: For organs fully covered within the scan volume, the average correlation of SSDE and organ absolute dose was found to be better than ±10%. In addition, this study provides a complete list of organ dose correlation factors (CF{sub SSDE}{sup organ}) for the chest and abdominopelvic regions, and describes a simple methodology to estimate individual pediatric patient organ dose based on patient SSDE.« less

  3. A Comparison of Patients Absorption Doses with Bone Deformity Due to the EOS Imaging and Digital Radiology

    PubMed Central

    Abrisham, Seyed Mohammad J.; Bouzarjomehri, Fathollah; Nafisi-Moghadam, Reza; Sobhan, Mohammad R.; Gadimi, Mahdie; Omidvar, Fereshte

    2017-01-01

    Background: This study has aimed to measure the patient dose in entire spine radiography by EOS system in comparison with the digital radiography. Methods: EOS stereo-radiography was used for frontal and lateral view spine imaging in 41 patients in a prospective analytical study. A calibrated dose area product (DAP) meter was used for calibration of the DAP in EOS system. The accuracy and precision of the system was confirmed according to the acceptance testing. The same procedure was used for 18 patients referred for lumbar spine digital radiology (overall 36 images). Results: Although radiation fields in the EOS were almost twice of that in digital radiology, and the average peak tube voltage (kVp), current supply to the tube (mA), and the average size and age of the patients referred for EOS imaging were greater than digital radiology, however, the average DAP in EOS was 1/5 of that in digital radiology system. Also, the average dose in the EOS was about 1/20 of that in digital radiology. Conclusion: The patient dose in EOS imaging system was lower in comparison with digital radiology (1/20). PMID:28656161

  4. A Comparison of Patients Absorption Doses with Bone Deformity Due to the EOS Imaging and Digital Radiology.

    PubMed

    Abrisham, Seyed Mohammad J; Bouzarjomehri, Fathollah; Nafisi-Moghadam, Reza; Sobhan, Mohammad R; Gadimi, Mahdie; Omidvar, Fereshte

    2017-05-01

    This study has aimed to measure the patient dose in entire spine radiography by EOS system in comparison with the digital radiography. EOS stereo-radiography was used for frontal and lateral view spine imaging in 41 patients in a prospective analytical study. A calibrated dose area product (DAP) meter was used for calibration of the DAP in EOS system. The accuracy and precision of the system was confirmed according to the acceptance testing. The same procedure was used for 18 patients referred for lumbar spine digital radiology (overall 36 images). Although radiation fields in the EOS were almost twice of that in digital radiology, and the average peak tube voltage (kV p ), current supply to the tube (mA), and the average size and age of the patients referred for EOS imaging were greater than digital radiology, however, the average DAP in EOS was 1/5 of that in digital radiology system. Also, the average dose in the EOS was about 1/20 of that in digital radiology. The patient dose in EOS imaging system was lower in comparison with digital radiology (1/20).

  5. AVERAGE ANNUAL SOLAR UV DOSE OF THE CONTINENTAL US CITIZEN

    EPA Science Inventory

    The average annual solar UV dose of US citizens is not known, but is required for relative risk assessments of skin cancer from UV-emitting devices. We solved this problem using a novel approach. The EPA's "National Human Activity Pattern Survey" recorded the daily ou...

  6. Breast imaging using an amorphous silicon-based full-field digital mammographic system: stability of a clinical prototype.

    PubMed

    Vedantham, S; Karellas, A; Suryanarayanan, S; D'Orsi, C J; Hendrick, R E

    2000-11-01

    An amorphous silicon-based full-breast imager for digital mammography was evaluated for detector stability over a period of 1 year. This imager uses a structured CsI:TI scintillator coupled to an amorphous silicon layer with a 100-micron pixel pitch and read out by special purpose electronics. The stability of the system was characterized using the following quantifiable metrics: conversion factor (mean number of electrons generated per incident x-ray), presampling modulation transfer function (MTF), detector linearity and sensitivity, detector signal-to-noise ratio (SNR), and American College of Radiology (ACR) accreditation phantom scores. Qualitative metrics such as flat field uniformity, geometric distortion, and Society of Motion Picture and Television Engineers (SMPTE) test pattern image quality were also used to study the stability of the system. Observations made over this 1-year period indicated that the maximum variation from the average of the measurements were less than 0.5% for conversion factor, 3% for presampling MTF over all spatial frequencies, 5% for signal response, linearity and sensitivity, 12% for SNR over seven locations for all 3 target-filter combinations, and 0% for ACR accreditation phantom scores. ACR mammographic accreditation phantom images indicated the ability to resolve 5 fibers, 4 speck groups, and 5 masses at a mean glandular dose of 1.23 mGy. The SMPTE pattern image quality test for the display monitors used for image viewing indicated ability to discern all contrast steps and ability to distinguish line-pair images at the center and corners of the image. No bleeding effects were observed in the image. Flat field uniformity for all 3 target-filter combinations displayed no artifacts such as gridlines, bad detector rows or columns, horizontal or vertical streaks, or bad pixels. Wire mesh screen images indicated uniform resolution and no geometric distortion.

  7. Getting started with protocol for quality assurance of digital mammography in the clinical centre of Montenegro.

    PubMed

    Ivanovic, S; Bosmans, H; Mijovic, S

    2015-07-01

    The purpose of this work is (i) to work out a test procedure for quality assurance (QA) in digital mammography with newly released test equipment, including the MagicMax mam multimeter (IBA, Germany) and the anthropomorphic tissue equivalent phantom Mammo AT (IBA, Germany), and (ii) to determine whether a first digital computer radiography (CR) system in Montenegro meets the current European standards. Tested parameters were tube output (µGy mAs(-1)) and output rate (mGy s(-1)), reproducibility and accuracy of tube voltage, half value layer, reproducibility and accuracy of the AEC system, exposure control steps, image receptor's response function, image quality and printer stability test. The evaluated dosimetric quantity is the average glandular dose (AGD) as evaluated from PMMA slabs simulating breast tissue. The main findings are that QA can be organised in Montenegro. (1) All measured parameters are within the range described in European protocols except the tube voltage which deviated more than ± 1 kV. The automatic determination of the HVL was satisfactorily. AGD ranged from 0.66 to 7.02 mGy for PMMA thicknesses from 20 to 70 mm, and is in accordance with literature data. (2) The image quality score as obtained with the anthropomorphic tissue equivalent phantom Mammo AT for the CR system was similar to findings on the authors' conventional screen-film mammography. (3) In clinical practice the mammograms are printed. The CR reader produces images with a pixel size of 43.75 µm, which is compatible with the laser printer (39 µm laser spot spacing). The image processing algorithm embedded in the reader successfully processes mammograms with desirable image brightness and contrast in the printed image. The authors conclude that this first digital mammography system seems a good candidate for breast cancer screening applications. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. BowelScope: Accuracy of Detection Using ENdocuff Optimisation of Mucosal Abnormalities

    ClinicalTrials.gov

    2017-05-05

    Colorectal Neoplasms; Colonic Polyp; Adenoma; Neoplasia GI; Digestive System Neoplasms; Intestinal Neoplasms; Neoplasms, Glandular and Epithelial; Digestive Disease; Intestinal Diseases; Colonic Diseases; Rectal Diseases; Intestinal Polyps; Polyps; Pathological Conditions, Anatomical

  9. Foliar anatomy and microscopy of six Brazilian species of Baccharis (Asteraceae).

    PubMed

    Budel, J M; Raman, V; Monteiro, L M; Almeida, V P; Bobek, V B; Heiden, G; Takeda, I J M; Khan, I A

    2018-04-27

    We report for the first time the presence of cluster crystals of calcium oxalate within the glandular trichomes and oil bodies in the mesophyll for Baccharis species. Moreover, the comparative leaf anatomy and micro-morphology of six species of Baccharis, namely B. illinita, B. microdonta, B. pauciflosculosa, B. punctulata, B. reticularioides, and B. sphenophylla is investigated by light and scanning electron microscopy. The studied species exhibited differences in their leaf anatomical features such as the morphology of the cuticle, type and occurrence of the stomata, presence or absence of glandular trichomes, shape of the flagelliform trichomes, and the arrangement of the mesophyll tissues. These differences can be helpful in the species identification and classification and could represent informative characters for the reconstruction of the evolution of the genus. © 2018 Wiley Periodicals, Inc.

  10. Mixed gynecomastia

    PubMed Central

    Qassabi, Salim S. Al; Al-Harthi, Saud M.; Al-Osali, Magdi E.

    2015-01-01

    Gynecomastia is an enlargement of male breast resulting from a proliferation of its glandular component, and it is usually due to an altered estrogen-androgen balance. It should be differentiated from pseudogynecomastia, which is characterized by fat deposition without glandular proliferation and from breast carcinoma. Gynecomastia could be physiological in neonates and pubertal or pathological due to drug intake, chronic liver, or renal disease, hyperthyroidism, testicular or adrenal neoplasms, and hypogonadism whether primary, or secondary. Properly organized work-up is needed to reach the cause of gynecomastia. Here, we reported a case of a young Omani man with gynecomastia with the aim of creating awareness of the occurrence of Klinefelter’s syndrome (KS) in patients with gynecomastia, to observe any differences in clinical presentation of KS from those reported in the literature, and highlight the needed diagnostic work-up and treatment. PMID:26318471

  11. Incidence of anti-intermediate filament antibody in serum samples of students with suspected glandular fever.

    PubMed

    Kataaha, P K; Holborow, E J; Edwards, J M

    1985-03-01

    Serum samples from 40 students with suspected infectious mononucleosis were tested for the presence of antibodies to intermediate filaments (AIFA) of the cytoskeleton. Twenty had antibodies to the Epstein-Barr virus capsid antigen before their illness, and during it their sera remained negative by the Paul-Bunnell test. The other 20 patients did not have antibodies to the Epstein-Barr virus capsid antigen before their illness and seroconverted during the illness. These patients (true infectious mononucleosis group) developed positive Paul-Bunnell tests. Sera from normal subjects (blood donors) were also tested for AIFA. AIFA was present in titres greater than 1/10 in 80% of the infectious mononucleosis group (mean titre 1/40-1/80), 10% of the Paul-Bunnell negative glandular fever group, and 8.5% of the normal blood donors.

  12. Mammary and extramammary Paget's disease

    PubMed Central

    Lloyd, J; Flanagan, A

    2000-01-01

    Mammary and extramammary Paget's disease are uncommon intraepithelial adenocarcinomas. Both conditions have similar clinical features, which mimic inflammatory and infective diseases. Histological diagnostic confusion can arise between Paget's disease and other neoplastic conditions affecting the skin, with the most common differential diagnoses being malignant melanoma and atypical squamous disease. The glandular differentiation of both mammary Paget's disease and extramammary Paget's disease is indicated by morphological appearances, the presence of intracellular mucin in many cases, and positive immunohistochemical staining for glandular cytokeratins, epithelial membrane antigen, and carcinoembryonic antigen. This article provides an overview of mammary and extramammary Paget's disease and discusses recent evidence regarding the cell of origin. The concepts of primary and secondary Paget's disease are presented and the differential diagnosis is discussed with reference to immunohistochemical markers that might be of diagnostic value. Key Words: mammary Paget's disease • extramammary Paget's disease PMID:11064666

  13. Warfarin Dosing Algorithms Underpredict Dose Requirements in Patients Requiring ≥7 mg Daily: A Systematic Review and Meta-analysis.

    PubMed

    Saffian, S M; Duffull, S B; Wright, Dfb

    2017-08-01

    There is preliminary evidence to suggest that some published warfarin dosing algorithms produce biased maintenance dose predictions in patients who require higher than average doses. We conducted a meta-analysis of warfarin dosing algorithms to determine if there exists a systematic under- or overprediction of dose requirements for patients requiring ≥7 mg/day across published algorithms. Medline and Embase databases were searched up to September 2015. We quantified the proportion of over- and underpredicted doses in patients whose observed maintenance dose was ≥7 mg/day. The meta-analysis included 47 evaluations of 22 different warfarin dosing algorithms from 16 studies. The meta-analysis included data from 1,492 patients who required warfarin doses of ≥7 mg/day. All 22 algorithms were found to underpredict warfarin dosing requirements in patients who required ≥7 mg/day by an average of 2.3 mg/day with a pooled estimate of underpredicted doses of 92.3% (95% confidence interval 90.3-94.1, I 2 = 24%). © 2017 American Society for Clinical Pharmacology and Therapeutics.

  14. Trans-nipple removal of fibro-glandular tissue in gynaecomastia surgery without additional scars: An innovative approach

    PubMed Central

    Mishra, R. K.

    2014-01-01

    Context: The established techniques that have been used to treat gynaecomastia are said to have relatively less patient satisfaction rate as they leave some visible scars or mild elevation over the nipple areola complex, resulting in aesthetically unsatisfactory results. Even the slightest elevation or smallest scar over nipple areola complex leave patients extremely self conscious and in a dilemma of having a second intervention to get rid of that blemish. Aims: The aim of the study is to achieve - A flat chest without adding a scar and with no chances of re-occurrence of the condition. This article suggests an innovative approach to address the problem. Materials and Methods: The author presents trans-nipple incision approach for the delivery of fibro-glandular tissue component following liposuction for maximum patient satisfaction. This method consists of a unique small criss-cross incision right on the nipple itself for retrieving any volume of tough fibro-glandular tissues. Between the duration of January 2012 to October 2013, 28 male patients of different ages were operated with this technique. Results: The surgery resulted in well-shaped, symmetric chest contour without any visible elevation or additional scars on nipple areola complex. No complications were noticed in any of the patients. Conclusions: The presented technique is proved to have a high patient satisfaction rate and to be promising method to achieve good aesthetic results in gynaecomastia surgery. PMID:24987204

  15. Comparative Transcriptome Analysis Identifies Putative Genes Involved in the Biosynthesis of Xanthanolides in Xanthium strumarium L.

    PubMed

    Li, Yuanjun; Gou, Junbo; Chen, Fangfang; Li, Changfu; Zhang, Yansheng

    2016-01-01

    Xanthium strumarium L. is a traditional Chinese herb belonging to the Asteraceae family. The major bioactive components of this plant are sesquiterpene lactones (STLs), which include the xanthanolides. To date, the biogenesis of xanthanolides, especially their downstream pathway, remains largely unknown. In X. strumarium, xanthanolides primarily accumulate in its glandular trichomes. To identify putative gene candidates involved in the biosynthesis of xanthanolides, three X. strumarium transcriptomes, which were derived from the young leaves of two different cultivars and the purified glandular trichomes from one of the cultivars, were constructed in this study. In total, 157 million clean reads were generated and assembled into 91,861 unigenes, of which 59,858 unigenes were successfully annotated. All the genes coding for known enzymes in the upstream pathway to the biosynthesis of xanthanolides were present in the X. strumarium transcriptomes. From a comparative analysis of the X. strumarium transcriptomes, this study identified a number of gene candidates that are putatively involved in the downstream pathway to the synthesis of xanthanolides, such as four unigenes encoding CYP71 P450s, 50 unigenes for dehydrogenases, and 27 genes for acetyltransferases. The possible functions of these four CYP71 candidates are extensively discussed. In addition, 116 transcription factors that are highly expressed in X. strumarium glandular trichomes were also identified. Their possible regulatory roles in the biosynthesis of STLs are discussed. The global transcriptomic data for X. strumarium should provide a valuable resource for further research into the biosynthesis of xanthanolides.

  16. Anatomy of the lactating human breast redefined with ultrasound imaging

    PubMed Central

    Ramsay, DT; Kent, JC; Hartmann, RA; Hartman, PE

    2005-01-01

    The aim of this study was to use ultrasound imaging to re-investigate the anatomy of the lactating breast. The breasts of 21 fully lactating women (1–6 months post partum) were scanned using an ACUSON XP10 (5–10 MHz linear array probe). The number of main ducts was measured, ductal morphology was determined, and the distribution of glandular and adipose tissue was recorded. Milk ducts appeared as hypoechoic tubular structures with echogenic walls that often contained echoes. Ducts were easily compressed and did not display typical sinuses. All ducts branched within the areolar radius, the first branch occurring 8.0 ± 5.5 mm from the nipple. Duct diameter was 1.9 ± 0.6 mm, 2.0 ± 90.7 mm and the number of main ducts was 9.6 ± 2.9, 9.2 ± 2.9, for left and right breast, respectively. Milk ducts are superficial, easily compressible and echoes within the duct represent fat globules in breastmilk. The low number and size of the ducts, the rapid branching under the areola and the absence of sinuses suggest that ducts transport breastmilk, rather than store it. The distribution of adipose and glandular tissue showed wide variation between women but not between breasts within women. The proportion of glandular and fat tissue and the number and size of ducts were not related to milk production. This study highlights inconsistencies in anatomical literature that impact on breast physiology, breastfeeding management and ultrasound assessment. PMID:15960763

  17. COX-2 expression in canine anal sac adenocarcinomas and in non-neoplastic canine anal sacs.

    PubMed

    Knudsen, C S; Williams, A; Brearley, M J; Demetriou, J L

    2013-09-01

    Anal sac adenocarcinoma (ASAC) is a clinically significant canine neoplasm characterized by early lymphatic invasion. Up-regulation of cyclooxygenase isoform 2 (COX-2) has been confirmed in several animal and human neoplastic tissues. The aim of the current study was primarily to evaluate COX-2 expression in canine ASAC and compare it to COX-2 expression in non-neoplastic canine anal sac tissue using immunohistochemistry with scoring for percentage positivity and intensity. Twenty-five ASAC samples and 22 normal anal sacs were available for evaluation. All canine ASAC samples and the normal anal sac tissues stained positively for COX-2. However, while normal anal sac tissue showed strong staining of the ductal epithelial cells, ASAC samples showed staining of the neoplastic glandular epithelial cells, with varying percentage positivity and intensity between ASAC samples. COX-2 immunoreactivity of ASAC samples was of low intensity in 52% and high in 12% of the cases; the remaining samples were of intermediate intensity. Seventy-six per cent of the ASAC had over 50% of the neoplastic glandular cells staining positive. These results confirm that COX-2 is expressed in the neoplastic glandular epithelial cells in canine ASAC and suggest a potential role for COX-2 inhibitors in the management of ASAC. Furthermore, the results indicate that COX-2 is expressed in ductal epithelial cells of the normal anal sac. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Surgical Strategies in the Treatment of Gynecomastia Grade I-II: The Combination of Liposuction and Subcutaneous Mastectomy Provides Excellent Patient Outcome and Satisfaction

    PubMed Central

    Schröder, Lars; Rudlowski, Christian; Walgenbach-Brünagel, Gisela; Leutner, Claudia; Kuhn, Walther; Walgenbach, Klaus-Jürgen

    2015-01-01

    Summary Background Gynecomastia (GM) is a benign condition with glandular tissue enlargement of the male breast. GM is classified into 4 grades of increasing severity. We describe a series of GM grade I-II, diagnosed, treated surgically and analyzed regarding feasibility, complication rate, and satisfaction. Methods From 2005 to 2012, a chart review was performed for 53 patients. Preoperative examination included endocrine and urological examination and exclusion of other pathological conditions. The surgical technique consisted of liposuction through an inframammarian-fold incision and excision of the glandular tissue by a minimal periareolar approach. Results A total number of 53 male patients with 104 breasts were available for analysis. By liposuction, a median of 300 ml (range: 10-1000 ml) was aspirated from each breast and 25.1 g (range: 3-233 g) gland tissue was resected. Surgery lasted between 25 and 164 min per patient (median: 72 min). 2 postoperative hemorrhages occurred (n = 2, 3.8%). 2 patients underwent re-operation due to cosmetic reasons (n = 2, 3.8%). Conclusions This analysis demonstrates that treatment of GM grade I-II can easily be performed by liposuction combined with subcutaneous resection of the glandular tissue as a minimally invasive and low-impact surgical treatment with a low rate of complications and excellent patient satisfaction. Preoperative workup is important to rule out specific diseases or malignancy causing the GM. PMID:26557823

  19. A novel cell-based assay for inhibitory anti-muscarinic type 3 receptor antibodies in primary Sjögren's syndrome.

    PubMed

    Bastian, Isabell; Gordon, Tom P; Jackson, Michael W

    2015-12-01

    Inhibitory autoantibodies acting at the muscarinic acetylcholine receptor type 3 (M3R) are postulated to mediate autonomic dysfunction, including decreased salivary and lacrimal gland output and extra-glandular manifestations, in patients with primary Sjögren's syndrome. However, the contention that anti-M3R antibodies are pathogenic in patients remains untested, due to a lack of assays both sophisticated enough to detect inhibitory anti-M3R antibodies yet suitable for screening large patient cohorts. In the current study, we have established a cell-based bioassay of M3R activity, based on dual transfection of the M3R and a luciferase reporter gene. The bioassay is capable of capturing real-time agonist-mediated signalling of the M3R, which is inhibited specifically by patient IgG that have previously been demonstrated to have anti-M3R activity. The assay can be run in multi-well culture plates, and analysed using simple luminescence readers. As such, the new bioassay incorporating M3R-mediated luciferase transduction is the first assay adaptable to common diagnostic platforms that is capable of determining the presence in patient serum of functionally active anti-M3R autoantibodies. The new bioassay should prove useful for large cohort screening studies aiming to correlate the presence in patients of inhibitory anti-M3R antibodies with symptoms of both glandular and extra-glandular autonomic dysfunction. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. [Metabolism of thyroid gland cells as affected by prolactin and emotional-physical stress].

    PubMed

    Strizhkov, V V

    1991-01-01

    A study was made of the role of prolactin (PRL) in the regulation of thyroid function in intact animals and in those exposed to stress (swimming was used as physical exercise). A single daily dose of 125 micrograms of PRL per 100 g of body mass was injected subcutaneously in 0.5 ml of saline solution during a week to male rats (control: intact rats; injection of 0.5 ml of saline solution subcutaneously). Redox enzymes; succinate dehydrogenase, lactate dehydrogenase, glucose-6-phosphate dehydrogenase, NAD.H2 and NADP.H2, ATPase and monoamine oxidase, total protein, RNA and glycogen in glandular cells were investigated histochemically 24 h after the last injection of PRL or saline, 30 min., 1, 2, 3, 5 and 7 hours after swimming or right after complete fatigue (in the presence of experimental hyperprolactinemia). A conclusion has been made that one of the most important mechanisms of the adaptive effect of PRL is its ability to suppress thyroid function, thus decreasing the metabolism level, which results in reduction of oxygen consumption and improves body tolerance to stress.

  1. Helodermatine, a kallikrein-like, hypotensive enzyme from the venom of Heloderma horridum horridum (Mexican beaded lizard)

    PubMed Central

    1986-01-01

    We have purified and characterized the major N-benzoyl-L-arginine ethyl ester hydrolase from the venom of Heloderma horridum horridum. The enzyme belongs to the serine proteinase family, and its activity vs. peptide amide substrates and human high-molecular-weight kininogen suggests a similarity to the family of kallikreins. This interpretation is corroborated by its reactivity with the natural inhibitors soybean trypsin inhibitor and Kunitz-type bovine pancreatic trypsin inhibitor (aprotinin). Injection of the enzyme (2-16 micrograms/kg) into anesthetized rabbits leads to a rapid dose-dependent transient decrease of the arterial blood pressure. Like glandular kallikrein it specifically converts single-chain tissue type plasminogen activator into its double chain form. In contrast to other kallikrein-like enzymes from snake venoms it shows no thrombin-like or plasminogen activator activity. The enzyme is a single-chain glycoprotein (Mr 63,000). The N-terminal sequence revealed significant homology to pig pancreatic kallikrein and to kallikrein like enzymes from Crotalus atrox and Crotalus adamanteus venom. This enzyme, which we name Helodermatine, is the first purified from Sauria with kallikrein-like properties. PMID:3537191

  2. A comparison of the dose from natural radionuclides and artificial radionuclides after the Fukushima nuclear accident

    PubMed Central

    Hosoda, Masahiro; Tokonami, Shinji; Omori, Yasutaka; Ishikawa, Tetsuo; Iwaoka, Kazuki

    2016-01-01

    Due to the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident, the evacuees from Namie Town still cannot reside in the town, and some continue to live in temporary housing units. In this study, the radon activity concentrations were measured at temporary housing facilities, apartments and detached houses in Fukushima Prefecture in order to estimate the annual internal exposure dose of residents. A passive radon–thoron monitor (using a CR-39) and a pulse-type ionization chamber were used to evaluate the radon activity concentration. The average radon activity concentrations at temporary housing units, including a medical clinic, apartments and detached houses, were 5, 7 and 9 Bq m−3, respectively. Assuming the residents lived in these facilities for one year, the average annual effective doses due to indoor radon in each housing type were evaluated as 0.18, 0.22 and 0.29 mSv, respectively. The average effective doses to all residents in Fukushima Prefecture due to natural and artificial sources were estimated using the results of the indoor radon measurements and published data. The average effective dose due to natural sources for the evacuees from Namie Town was estimated to be 1.9 mSv. In comparison, for the first year after the FDNPP accident, the average effective dose for the evacuees due to artificial sources from the accident was 5.0 mSv. Although residents' internal and external exposures due to natural radionuclides cannot be avoided, it might be possible to lower external exposure due to the artificial radionuclides by changing some behaviors of residents. PMID:26838130

  3. SU-F-T-57: Delivered Activity Accuracy of Radium 223 Dichloride Injections, When Being Administrated for Castration Resistant Prostate Cancer, Symptomatic Bone Metastases. The Impact of Residual Activity in the Spent Syringe and Dispensing Accuracy of Ra 223

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jennings, G

    Purpose: To quantify the delivered activity accuracy of Radium 223 dichloride injections, when being administrated for castration – resistant prostate cancer, symptomatic bone metastases. The impact of residual activity in the spent syringe and dispensing accuracy of Ra 223. Methods: The administration is by slow intravenous injection over 1 minute followed by double flushing of the 10 mL syringe and IV with saline. Eighty (80) procedures was used to investigate variations in the activity from the amount prescribed (µCi) = 1.35 × Patient weight Kg. The Activity dispensed into a 10mL syringe using a NIST traceable Capintec CRC-25R Chamber andmore » a cross calibrated capintec CRC-15R to measure activity in the syringe immediately before and after administration Results: The patients weight range from 121Ib to 235lb and doses ranging 74.25 µCi to 144.2 µCi. The deviation of dispensed dose vs Prescribed dose average +2.1% with a range of −1.1% to +5.7%. The Dose measured before administration ranges 79.3 µCi to 154.9 µCi. Deviation from the dispensed dose was show to average +2.9% with a range of −0.8% to +7.3%. The average residual dose post injection was 2.5 µCi or 2.2% of the pre injection activity. Ranging from 0.9 µCi to 6.2 µCi, 0.7% to 5.4% respectively. Subtracting the residual activity from that measured activity before injection and comparing it to prescription dose was shown to have an average variation of +2.7% with a range of −0.8% to 7.4%. Conclusion: The case resulted in the 6.2 µCi maximum residual dose had two syringes. A small, 82.8 µCi activity, case resulted in the 7.4% maximum variation in measures less residual verses prescription dose. The average +2.1 % dispenses activity of Ra 223 over the prescription dosage was seen to counteract the average 2.2% residual dosage found to remain in the syringe.« less

  4. Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riegel, Adam C.; Ahmad, Moiz; Sun Xiaojun

    2008-12-15

    Dose calculation for thoracic radiotherapy is commonly performed on a free-breathing helical CT despite artifacts caused by respiratory motion. Four-dimensional computed tomography (4D-CT) is one method to incorporate motion information into the treatment planning process. Some centers now use the respiration-averaged CT (RACT), the pixel-by-pixel average of the ten phases of 4D-CT, for dose calculation. This method, while sparing the tedious task of 4D dose calculation, still requires 4D-CT technology. The authors have recently developed a means to reconstruct RACT directly from unsorted cine CT data from which 4D-CT is formed, bypassing the need for a respiratory surrogate. Using RACTmore » from cine CT for dose calculation may be a means to incorporate motion information into dose calculation without performing 4D-CT. The purpose of this study was to determine if RACT from cine CT can be substituted for RACT from 4D-CT for the purposes of dose calculation, and if increasing the cine duration can decrease differences between the dose distributions. Cine CT data and corresponding 4D-CT simulations for 23 patients with at least two breathing cycles per cine duration were retrieved. RACT was generated four ways: First from ten phases of 4D-CT, second, from 1 breathing cycle of images, third, from 1.5 breathing cycles of images, and fourth, from 2 breathing cycles of images. The clinical treatment plan was transferred to each RACT and dose was recalculated. Dose planes were exported at orthogonal planes through the isocenter (coronal, sagittal, and transverse orientations). The resulting dose distributions were compared using the gamma ({gamma}) index within the planning target volume (PTV). Failure criteria were set to 2%/1 mm. A follow-up study with 50 additional lung cancer patients was performed to increase sample size. The same dose recalculation and analysis was performed. In the primary patient group, 22 of 23 patients had 100% of points within the PTV pass {gamma} criteria. The average maximum and mean {gamma} indices were very low (well below 1), indicating good agreement between dose distributions. Increasing the cine duration generally increased the dose agreement. In the follow-up study, 49 of 50 patients had 100% of points within the PTV pass the {gamma} criteria. The average maximum and mean {gamma} indices were again well below 1, indicating good agreement. Dose calculation on RACT from cine CT is negligibly different from dose calculation on RACT from 4D-CT. Differences can be decreased further by increasing the cine duration of the cine CT scan.« less

  5. Shielding properties of lead-free protective clothing and their impact on radiation doses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schlattl, Helmut; Zankl, Maria; Eder, Heinrich

    2007-11-15

    The shielding properties of two different lead-free materials--tin and a compound of 80% tin and 20% bismuth--for protective clothing are compared with those of lead for three typical x-ray spectra generated at tube voltages of 60, 75, and 120 kV. Three different quantities were used to compare the shielding capability of the different materials: (1) Air-kerma attenuation factors in narrow-beam geometry, (2) air-kerma attenuation factors in broad-beam geometry, and (3) ratios of organ and effective doses in the human body for a whole-body irradiation with a parallel beam directed frontally at the body. The thicknesses of tin (0.45 mm) andmore » the tin/bismuth compound (0.41 mm) to be compared against lead correspond to a lead equivalence value of 0.35 mm for the 75 kV spectrum. The narrow-beam attenuation factors for 0.45 mm tin are 54% and 32% lower than those for 0.35 mm lead for 60 and 120 kV; those for 0.41 mm tin/bismuth are 12% and 32% lower, respectively. The decrease of the broad-beam air-kerma attenuation factors compared to lead is 74%, 46%, and 41% for tin and 42%, 26%, and 33% for tin/bismuth and the spectra at 60, 75, and 120 kV, respectively. Therefore, it is recommended that the characterization of the shielding potential of a material should be done by measurements in broad-beam geometry. Since the secondary radiation that is mainly responsible for the shielding reduction in broad-beam geometry is of low penetrability, only more superficially located organs receive significantly enhanced doses. The increase for the dose to the glandular breast tissue (female) compared to being shielded by lead is 143%, 37%, and 45% when shielded by tin, and 35%, 15%, and 39% when shielded by tin/bismuth for 60, 75, and 120 kV, respectively. The effective dose rises by 60%, 6%, and 38% for tin, and 14%, 3% and, 35% for tin/bismuth shielding, respectively.« less

  6. Dosimetric Evaluation Between Megavoltage Cone-Beam Computed Tomography and Body Mass Index for Intracranial, Thoracic, and Pelvic Localization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    VanAntwerp, April E.; Raymond, Sarah M., E-mail: raymons9@ccf.org; Addington, Mark C.

    2011-10-01

    The aim of this study was to evaluate radiation dose for organs at risk (OAR) within the cranium, thorax, and pelvis from megavoltage cone-beam computed tomography (MV-CBCT). Using a clinical treatment planning system, CBCT doses were calculated from 60 patient datasets using 27.4 x 27.4 cm{sup 2} field size and 200{sup o} arc length. The body mass indices (BMIs) for these patients range from 17.2-48.4 kg/m{sup 2}. A total of 60 CBCT plans were created and calculated with heterogeneity corrections, with monitor units (MU) that varied from 8, 4, and 2 MU per plan. The isocenters of these plans weremore » placed at defined anatomical structures. The maximum dose, dose to the isocenter, and mean dose to the selected critical organs were analyzed. The study found that maximum and isocenter doses were weakly associated with BMI, but linearly associated with the total MU. Average maximum/isocenter doses in the cranium were 10.0 ({+-} 0.18)/7.0 ({+-} 0.08) cGy, 5.0 ({+-} 0.09)/3.5 ({+-} 0.05) cGy, and 2.5 ({+-} .04)/1.8 ({+-} 0.05) cGy for 8, 4, and 2 MU, respectively. Similar trends but slightly larger maximum/isocenter doses were found in the thoracic and pelvic regions. For the cranial region, the average mean doses with a total of 8 MU to the eye, lens, and brain were 9.7 ({+-} 0.12) cGy, 9.1 ({+-} 0.16) cGy, and 7.2 ({+-} 0.10) cGy, respectively. For the thoracic region, the average mean doses to the lung, heart, and spinal cord were 6.6 ({+-} 0.05) cGy, 6.9 ({+-} 1.2) cGy, and 4.7 ({+-} 0.8) cGy, respectively. For the pelvic region, the average mean dose to the femoral heads was 6.4 ({+-} 1.1) cGy. The MV-CBCT doses were linearly associated with the total MU but weakly dependent on patients' BMIs. Daily MV-CBCT has a cumulative effect on the total body dose and critical organs, which should be carefully considered for clinical impacts.« less

  7. SU-F-J-29: Dosimetric Effect of Image Registration ROI Size and Focus in Automated CBCT Registration for Spine SBRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Magnelli, A; Smith, A; Chao, S

    2016-06-15

    Purpose: Spinal stereotactic body radiotherapy (SBRT) involves highly conformal dose distributions and steep dose gradients due to the proximity of the spinal cord to the treatment volume. To achieve the planning goals while limiting the spinal cord dose, patients are setup using kV cone-beam CT (kV-CBCT) with 6 degree corrections. The kV-CBCT registration with the reference CT is dependent on a user selected region of interest (ROI). The objective of this work is to determine the dosimetric impact of ROI selection. Methods: Twenty patients were selected for this study. For each patient, the kV-CBCT was registered to the reference CTmore » using three ROIs including: 1) the external body, 2) a large anatomic region, and 3) a small region focused in the target volume. Following each registration, the aligned CBCTs and contours were input to the treatment planning system for dose evaluation. The minimum dose, dose to 99% and 90% of the tumor volume (D99%, D90%), dose to 0.03cc and the dose to 10% of the spinal cord subvolume (V10Gy) were compared to the planned values. Results: The average deviations in the tumor minimum dose were 2.68%±1.7%, 4.6%±4.0%, 14.82%±9.9% for small, large and the external ROIs, respectively. The average deviations in tumor D99% were 1.15%±0.7%, 3.18%±1.7%, 10.0%±6.6%, respectively. The average deviations in tumor D90% were 1.00%±0.96%, 1.14%±1.05%, 3.19%±4.77% respectively. The average deviations in the maximum dose to the spinal cord were 2.80%±2.56%, 7.58%±8.28%, 13.35%±13.14%, respectively. The average deviation in V10Gy to the spinal cord were 1.69%±0.88%, 1.98%±2.79%, 2.71%±5.63%. Conclusion: When using automated registration algorithms for CBCT-Reference alignment, a small target-focused ROI results in the least dosimetric deviation from the plan. It is recommended to focus narrowly on the target volume to keep the spinal cord dose below tolerance.« less

  8. SU-F-T-539: Dosimetric Comparison of Volumetric Modulated Arc Therapy and Intensity Modulated Radiation Therapy for Whole Brain Hippocampal Sparing Radiation Therapy Treatments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kendall, E; Higby, C; Algan, O

    2016-06-15

    Purpose: To compare the treatment plan quality and dose gradient near the hippocampus between VMAT (RapidArc) and IMRT delivery techniques for whole brain radiation therapy. Methods: Fifteen patients were evaluated in this retrospective study. All treatments were planned on Varian Eclipse TPS, using 3-Arc VMAT and 9-Field IMRT, following NRG Oncology protocol NRG-CC001 guidelines evaluated by a single radiation oncologist. Prescribed doses in all plans were 30 Gy delivered over 10 fractions normalized to a minimum of 100% of the dose covering 95% of the target volume. Identical contour sets and dose-volume constraints following protocol guidelines were also applied inmore » all plans. A paired t-test analysis was used to compare VMAT and IMRT plans. Results: NRG-CC001 protocol dose-volume constraints were met for all VMAT and IMRT plans. For the planning target volume (PTV), the average values for D2% and D98% were 6% lower and 4% higher in VMAT than in IMRT, respectively. The average mean and maximum hippocampus doses in Gy for VMAT vs IMRT plans were (11.85±0.81 vs. 12.24±0.56, p=0.10) and (16.27±0.78 vs. 16.59±0.71, p=0.24), respectively. In VMAT, the average mean and maximum chiasm doses were 3% and 1% higher than in IMRT plans, respectively. For the left optic nerve, the average mean and maximum doses were 10% and 5% higher in VMAT than in IMRT plans, respectively. These values were 12% and 3% for the right optic nerve. The average percentage of dose gradient around the hippocampus in the 0–5mm and 5–10mm abutted regions for VMAT vs. IMRT were (4.42%±2.22% /mm vs. 3.95%±2.61% /mm, p=0.43) and (4.54%±1.50% /mm vs. 4.39%±1.28% /mm, p=0.73), respectively. Conclusion: VMAT plans can achieve higher hippocampus sparing with a faster dose fall-off than IMRT plans. Though statistically insignificant, VMAT offers better PTV coverage with slightly higher doses to OARs.« less

  9. 27 CFR 21.33 - Formula No. 2-B.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... crude drugs. 342.Processing glandular products, vitamins, hormones, and yeasts. 343.Processing... the appropriate TTB officer. [T.D. ATF-133, 48 FR 24673, June 2, 1983, as amended by T.D. ATF-442, 66...

  10. The comparative short-term effectiveness of iron dosing and formulations in US hemodialysis patients.

    PubMed

    Kshirsagar, Abhijit V; Freburger, Janet K; Ellis, Alan R; Wang, Lily; Winkelmayer, Wolfgang C; Brookhart, M Alan

    2013-06-01

    Intravenous iron is used widely in hemodialysis, yet there are limited data on the effectiveness of contemporary dosing strategies or formulation type. We conducted a retrospective cohort study using data from the clinical database of a large dialysis provider (years 2004-2008) merged with administrative data from the US Renal Data System to compare the effects of intravenous iron use on anemia management. Dosing comparisons were bolus (consecutive doses ≥100 mg exceeding 600 mg during 1 month) versus maintenance (all other iron doses during the month); and high (>200 mg over 1 month) versus low dose (≤200 mg over 1 month). Formulation comparison was administration of ferric gluconate versus iron sucrose over 1 month. Outcomes were hemoglobin, epoetin dose, transferrin saturation, and serum ferritin during 6 weeks of follow-up. We identified 117,050 patients for the dosing comparison, and 66,207 patients for the formulation comparison. Bolus dosing was associated with higher average adjusted hemoglobin (+0.23 g/dL; 95% confidence interval [CI], 0.21-0.26), transferrin saturation (+3.31%; 95% CI, 2.99-3.63), serum ferritin (+151 μg/L; 95% CI, 134.9-168.7), and lower average epoetin dose (-464 units; 95% CI, -583 to -343) compared with maintenance. Similar trends were observed with high-dose iron versus low-dose. Iron sucrose was associated with higher adjusted average hemoglobin (+0.16 g/dL; 95% CI, 0.12-0.19) versus ferric gluconate. Strategies favoring large doses of intravenous iron or iron sucrose lead to improved measures of anemia management. These potential benefits should be weighed against risks, which currently remain incompletely characterized. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Some cosmic radiation dose measurements aboard flights connecting Zagreb Airport.

    PubMed

    Vuković, B; Radolić, V; Lisjak, I; Vekić, B; Poje, M; Planinić, J

    2008-02-01

    When primary particles from space, mainly protons, enter the atmosphere, they produce interactions with air nuclei, and cosmic-ray showers are induced. The radiation field at aircraft altitude is complex, with different types of particles, mainly photons, electrons, positrons and neutrons, with a large energy range. The non-neutron component of cosmic radiation dose aboard A320 and ATR40 aircraft was measured with TLD-100 (LiF:Mg,Ti) detectors and the Mini 6100 semiconductor dosimeter; the neutron dose was measured with the neutron dosimeter consisted of LR-115 track detector and boron foil BN-1 or 10B converter. The estimated occupational effective dose for the aircraft crew (A320) working 500 h per year was 1.64 mSv. Another experiment was performed at the flights Zagreb-Paris-Buenos Aires and reversely, when one measured non-neutron cosmic radiation dose; for 26.7 h of flight, the MINI 6100 dosimeter gave an average dose rate of 2.3 microSv/h and the TLD dosimeter registered the dose equivalent of 75 microSv or the average dose rate of 2.7 microSv/h; the neutron dosimeter gave the dose rate of 2.4 microSv/h. In the same month, February 2005, a traveling to Japan (24-h-flight: Zagreb-Frankfurt-Tokyo and reversely) and the TLD-100 measurement showed the average dose rate of 2.4microSv/h; the neutron dosimeter gave the dose rate of 2.5 microSv/h. Comparing dose rates of the non-neutron component (low LET) and the neutron one (high LET) of the radiation field at the aircraft flight level, we could conclude that the neutron component carried about 50% of the total dose, that was near other known data.

  12. Synergism between Sodium Chloride and Sodium Taurocholate and Development of Pepsinogen‐altered Pyloric Glands: Relevance to a Medium‐term Bioassay System for Gastric Carcinogens and Promoters in Rats

    PubMed Central

    Tatematsu, Masae; Mutai, Mamoru; Inoue, Kaoru; Ozaki, Keisuke; Furihata, Chie; Ito, Nobuyuki

    1989-01-01

    In an approach to early detection of gastric carcinogens and promoters in an in vivo test system, promotion by sodium chloride (NaCl) and the synergistic effects of NaCl and sodium taurocholate (Na‐TC) on development of pepsinogen‐altered pyloric glands (PAPG) in rat glandular stomach after initiation with N‐methyl‐N′‐nitro‐N‐nitrosoguanidine (MNNG) were investigated. A total of 205 male WKY/NCrj rats were divided into 8 groups. Group 1 was given a single dose of MNNG of 160 mg/ kg body weight by gastric intubation, and starting 2 weeks later basal diet containing Na‐TC for 18 weeks. In addition, 1 ml doses of saturated NaCl solution were given by gastric intubation at weeks 4, 6, 8 and 10. Similarly, group 2 was treated with MNNG and Na‐TC, while group 3 animals received MNNG and NaCl. Group 4 was given MNNG alone. Groups 5–8 served as equivalent controls without MNNG initiation. The results revealed significantly enhanced induction of immunohisto‐chemically defined PAPG in the Na‐TC + NaCl (P< 0.001), Na‐TC (P<0.01) and NaCl (P<0.01) treated animals initiated with MNNG. Sodium chloride demonstrated a clear synergistic effect with Na‐TC in promoting the development of PAPG, suggesting possible advantage for its use in medium‐term in vivo assays for detection of gastric carcinogens and promoters. PMID:2514164

  13. SU-E-T-454: Impact of Calculation Grid Size On Dosimetry and Radiobiological Parameters for Head and Neck IMRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Srivastava, S; Das, I; Indiana University Health Methodist Hospital, Indianapolis, IN

    2014-06-01

    Purpose: IMRT has become standard of care for complex treatments to optimize dose to target and spare normal tissues. However, the impact of calculation grid size is not widely known especially dose distribution, tumor control probability (TCP) and normal tissue complication probability (NTCP) which is investigated in this study. Methods: Ten head and neck IMRT patients treated with 6 MV photons were chosen for this study. Using Eclipse TPS, treatment plans were generated for different grid sizes in the range 1–5 mm for the same optimization criterion with specific dose-volume constraints. The dose volume histogram (DVH) was calculated for allmore » IMRT plans and dosimetric data were compared. ICRU-83 dose points such as D2%, D50%, D98%, as well as the homogeneity and conformity indices (HI, CI) were calculated. In addition, TCP and NTCP were calculated from DVH data. Results: The PTV mean dose and TCP decreases with increasing grid size with an average decrease in mean dose by 2% and TCP by 3% respectively. Increasing grid size from 1–5 mm grid size, the average mean dose and NTCP for left parotid was increased by 6.0% and 8.0% respectively. Similar patterns were observed for other OARs such as cochlea, parotids and spinal cord. The HI increases up to 60% and CI decreases on average by 3.5% between 1 and 5 mm grid that resulted in decreased TCP and increased NTCP values. The number of points meeting the gamma criteria of ±3% dose difference and ±3mm DTA was higher with a 1 mm on average (97.2%) than with a 5 mm grid (91.3%). Conclusion: A smaller calculation grid provides superior dosimetry with improved TCP and reduced NTCP values. The effect is more pronounced for smaller OARs. Thus, the smallest possible grid size should be used for accurate dose calculation especially in H and N planning.« less

  14. A Comparative Evaluation of Normal Tissue Doses for Patients Receiving Radiation Therapy for Hodgkin Lymphoma on the Childhood Cancer Survivor Study and Recent Children's Oncology Group Trials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Rachel; Ng, Angela; Constine, Louis S.

    Purpose: Survivors of pediatric Hodgkin lymphoma (HL) are recognized to have an increased risk of delayed adverse health outcomes related to radiation therapy (RT). However, the necessary latency required to observe these late effects means that the estimated risks apply to outdated treatments. We sought to compare the normal tissue dose received by children treated for HL and enrolled in the Childhood Cancer Survivor Study (CCSS) (diagnosed 1970-1986) with that of patients treated in recent Children's Oncology Group (COG) trials (enrolled 2002-2012). Methods and Materials: RT planning data were obtained for 50 HL survivors randomly sampled from the CCSS cohortmore » and applied to computed tomography planning data sets to reconstruct the normal tissue dosimetry. For comparison, the normal tissue dosimetry data were obtained for all 191 patients with full computed tomography–based volumetric RT planning on COG protocols AHOD0031 and AHOD0831. Results: For early-stage patients, the mean female breast dose in the COG patients was on average 83.5% lower than that for CCSS patients, with an absolute reduction of 15.5 Gy. For advanced-stage patients, the mean breast dose was decreased on average by 70% (11.6 Gy average absolute dose reduction). The mean heart dose decreased on average by 22.9 Gy (68.6%) and 17.6 Gy (56.8%) for early- and advanced-stage patients, respectively. All dose comparisons for breast, heart, lung, and thyroid were significantly lower for patients in the COG trials than for the CCSS participants. Reductions in the prescribed dose were a major contributor to these dose reductions. Conclusions: These are the first data quantifying the significant reduction in the normal tissue dose using actual, rather than hypothetical, treatment plans for children with HL. These findings provide useful information when counseling families regarding the risks of contemporary RT.« less

  15. Gamma Radiation Dose Rate in Air due to Terrestrial Radionuclides in Southern Brazil: Synthesis by Geological Units and Lithotypes Covered by the Serra do Mar Sul Aero-Geophysical Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bastos, Rodrigo O.; Appoloni, Carlos R.; Pinese, Jose P. P.

    2008-08-07

    The absorbed dose rates in air due to terrestrial radionuclides were estimated from aerial gamma spectrometric data for an area of 48,600 km{sup 2} in Southern Brazil. The source data was the Serra do Mar Sul Aero-Geophysical Project back-calibrated in a cooperative work among the Geological Survey of Brazil, the Geological Survey of Canada, and Paterson, Grant and Watson Ltd. The concentrations of eU (ppm), eTh (ppm) and K (%) were converted to dose rates in air (nGy{center_dot}h{sup -1}) by accounting for the contribution of each element's concentration. Regional variation was interpreted according to lithotypes and a synthesis was performedmore » according to the basic geological units present in the area. Higher values of total dose were estimated for felsic igneous and metamorphic rocks, with average values varying up to 119{+-}24 nGy{center_dot}h{sup -1}, obtained by Anitapolis syenite body. Sedimentary, metasedimentary and metamafic rocks presented the lower dose levels, and some beach deposits reached the lowest average total dose, 18.5{+-}8.2 nGy{center_dot}h{sup -1}. Thorium gives the main average contribution in all geological units, the highest value being reached by the nebulitic gneisses of Atuba Complex, 71{+-}23 nGy{center_dot}h{sup -1}. Potassium presents the lowest average contribution to dose rate in 53 of the 72 units analyzed, the highest contribution being obtained by intrusive alkaline bodies (28{+-}12 nGy{center_dot}h{sup -1}). The general pattern of geographic dose distribution respects well the hypotheses on geo-physicochemical behavior of radioactive elements.« less

  16. Comparison of the Pharmacoeconomics of Calfactant and Poractant Alfa in Surfactant Replacement erapy.

    PubMed

    Zayek, Michael M; Eyal, Fabien G; Smith, Robert C

    2018-01-01

    To compare the pharmacy costs of calfactant (Infasurf, ONY, Inc.) and poractant alfa (Curosurf, Chiesi USA, Inc., Cary, NC). The University of South Alabama Children's and Women's Hospital switched from calfactant to poractant alfa in 2013 and back to calfactant in 2015. Retrospectively, we used deidentified data from pharmacy records that provided type of surfactant administered, gestational age, birth weight, and number of doses on each patient. We examined differences in the number of doses by gestational ages and the differences in costs by birth weight cohorts because cost per dose is based on weight. There were 762 patients who received calfactant and 432 patients who received poractant alfa. The average number of doses required per patient was 1.6 administrations for calfactant-treated patients and 1.7 administrations for poractant alfa-treated patients, p = 0.03. A higher percentage of calfactant patients needed only 1 dose (53%) than poractant alfa patients (47%). The distribution of the number of doses for calfactant-treated patients was significantly lower than for the poractant alfa-patients, p < 0.001. Gestational age had no consistent effect on the number of doses required for either calfactant or poractant alfa. Per patient cost was higher for poractant alfa than for calfactant in all birth weight cohorts. Average per patient cost was $1160.62 for poractant alfa, 38% higher than the average per patient cost for calfactant ($838.34). Using poractant alfa for 22 months is estimated to have cost $202,732.75 more than it would have cost if the hospital had continued using calfactant. Our experience showed a strong pharmacoeconomic advantage for the use of calfactant compared to the use of poractant alfa because of similar average dosing and lower per patient drug costs.

  17. Analytical optimization of digital subtraction mammography with contrast medium using a commercial unit.

    PubMed

    Rosado-Méndez, I; Palma, B A; Brandan, M E

    2008-12-01

    Contrast-medium-enhanced digital mammography (CEDM) is an image subtraction technique which might help unmasking lesions embedded in very dense breasts. Previous works have stated the feasibility of CEDM and the imperative need of radiological optimization. This work presents an extension of a former analytical formalism to predict contrast-to-noise ratio (CNR) in subtracted mammograms. The goal is to optimize radiological parameters available in a clinical mammographic unit (x-ray tube anode/filter combination, voltage, and loading) by maximizing CNR and minimizing total mean glandular dose (D(gT)), simulating the experimental application of an iodine-based contrast medium and the image subtraction under dual-energy nontemporal, and single- or dual-energy temporal modalities. Total breast-entrance air kerma is limited to a fixed 8.76 mGy (1 R, similar to screening studies). Mathematical expressions obtained from the formalism are evaluated using computed mammographic x-ray spectra attenuated by an adipose/glandular breast containing an elongated structure filled with an iodinated solution in various concentrations. A systematic study of contrast, its associated variance, and CNR for different spectral combinations is performed, concluding in the proposal of optimum x-ray spectra. The linearity between contrast in subtracted images and iodine mass thickness is proven, including the determination of iodine visualization limits based on Rose's detection criterion. Finally, total breast-entrance air kerma is distributed between both images in various proportions in order to maximize the figure of merit CNR2/D(gT). Predicted results indicate the advantage of temporal subtraction (either single- or dual-energy modalities) with optimum parameters corresponding to high-voltage, strongly hardened Rh/Rh spectra. For temporal techniques, CNR was found to depend mostly on the energy of the iodinated image, and thus reduction in D(gT) could be achieved if the spectral energy of the noniodinated image is decreased and the breast-entrance air kerma is evenly distributed between both acquisitions. Predicted limits, in terms of iodine concentration, are found to guarantee the visualization of common clinical angiogenic concentrations in the breast.

  18. In vivo dose verification method in catheter based high dose rate brachytherapy.

    PubMed

    Jaselskė, Evelina; Adlienė, Diana; Rudžianskas, Viktoras; Urbonavičius, Benas Gabrielis; Inčiūra, Arturas

    2017-12-01

    In vivo dosimetry is a powerful tool for dose verification in radiotherapy. Its application in high dose rate (HDR) brachytherapy is usually limited to the estimation of gross errors, due to inability of the dosimetry system/ method to record non-uniform dose distribution in steep dose gradient fields close to the radioactive source. In vivo dose verification in interstitial catheter based HDR brachytherapy is crucial since the treatment is performed inserting radioactive source at the certain positions within the catheters that are pre-implanted into the tumour. We propose in vivo dose verification method for this type of brachytherapy treatment which is based on the comparison between experimentally measured and theoretical dose values calculated at well-defined locations corresponding dosemeter positions in the catheter. Dose measurements were performed using TLD 100-H rods (6 mm long, 1 mm diameter) inserted in a certain sequences into additionally pre-implanted dosimetry catheter. The adjustment of dosemeter positioning in the catheter was performed using reconstructed CT scans of patient with pre-implanted catheters. Doses to three Head&Neck and one Breast cancer patient have been measured during several randomly selected treatment fractions. It was found that the average experimental dose error varied from 4.02% to 12.93% during independent in vivo dosimetry control measurements for selected Head&Neck cancer patients and from 7.17% to 8.63% - for Breast cancer patient. Average experimental dose error was below the AAPM recommended margin of 20% and did not exceed the measurement uncertainty of 17.87% estimated for this type of dosemeters. Tendency of slightly increasing average dose error was observed in every following treatment fraction of the same patient. It was linked to the changes of theoretically estimated dosemeter positions due to the possible patient's organ movement between different treatment fractions, since catheter reconstruction was performed for the first treatment fraction only. These findings indicate potential for further average dose error reduction in catheter based brachytherapy by at least 2-3% in the case that catheter locations will be adjusted before each following treatment fraction, however it requires more detailed investigation. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  19. Assessment of the mean glandular dose using LiF:Mg,Ti, LiF:Mg,Cu,P, Li2B4O7:Mn and Li2B4O7:Cu TL detectors in mammography radiation fields

    NASA Astrophysics Data System (ADS)

    Fartaria, M. J.; Reis, C.; Pereira, J.; Pereira, M. F.; Cardoso, J. V.; Santos, L. M.; Oliveira, C.; Holovey, V.; Pascoal, A.; Alves, J. G.

    2016-09-01

    The aim of this paper is the characterization of four thermoluminescence detectors (TLD), namely, LiF:Mg,Ti, LiF:Mg,Cu,P, Li2B4O7:Mn and Li2B4O7:Cu for the measurement of the entrance surface air kerma (ESAK) and estimation of the mean glandular dose (MGD) in digital mammography examinations at hospitals and clinics. Low-energy x-ray beams in the typical energy ranges of mammography, produced with a tungsten target and additional 60 µm molybdenum filtration were implemented and characterized at the Laboratory of Metrology of Ionizing Radiation at Instituto Superior Técnico. These beams were used for the characterization of the TLDs in terms of sensitivity, linearity, reproducibility, energy dependence and fading at 40 °C. The energy dependence test was further extended using clinical beams produced by mammography units at hospitals and clinics. The method proposed by the International Atomic Energy Agency was used for the measurement of ESAK and assessment of MGD. The combined standard uncertainty for the measurement of ESAK (and MGD) was determined in accordance to the Guide to the expression of uncertainty in measurement. The x-ray beams generated in the 23-40 kVp range presented HVL values from 0.36 to 0.46 mm Al. The beam produced at 28 kVp (HVL 0.39 mm Al) was considered as reference. The radiation field defined a circle with 84 mm diameter with a maximum variation of the beam intensity of less than 1% at the top flat (plateau) within 4 cm of the central axis. The estimated total uncertainty for the measurement of air kerma was 0.42%. All the TL detectors tested showed good performance except the commercial Li2B4O7:Mn (or TLD-800) which was excluded due to its poor sensitivity in our experimental set up. Both lithium fluorides showed better linearity and reproducibility as well as lower energy dependence and fading when compared to lithium borates. The stable behaviour of LiF:Mg,Ti and LiF:Mg,Cu,P detectors is reflected in the low combined standard uncertainty of  ±5.6% and  ±4.3% respectively (or  ±5.1% and  ±3.6% if fading is neglected). In general a total combined uncertainty lower than  ±10% for the measurement of ESAK was obtained for the four TL materials studied.

  20. Latin American dose survey results in mammography studies under IAEA programme: radiological protection of patients in medical exposures (TSA3).

    PubMed

    Mora, Patricia; Blanco, Susana; Khoury, Helen; Leyton, Fernando; Cárdenas, Juan; Defaz, María Yolanda; Garay, Fernando; Telón, Flaviano; Aguilar, Juan Garcia; Roas, Norma; Gamarra, Mirtha; Blanco, Daniel; Quintero, Ana Rosa; Nader, Alejandro

    2015-03-01

    Latin American countries (Argentina, Brazil, Chile, Costa Rica, Cuba, Ecuador, El Salvador, Guatemala, Mexico, Nicaragua, Paraguay, Uruguay and Venezuela) working under the International Atomic Energy Agency (IAEA) Technical Cooperation Programme: TSA3 Radiological Protection of Patients in Medical Exposures have joined efforts in the optimisation of radiation protection in mammography practice. Through surveys of patient doses, the region has a unique database of diagnostic reference levels for analogue and digital equipment that will direct future optimisation activities towards the early detection of breast cancer among asymptomatic women. During RLA9/057 (2007-09) 24 institutions participated with analogue equipment in a dose survey. Regional training on methodology and measurement equipment was addressed in May 2007. The mean glandular dose (DG) was estimated using the incident kerma in air and relevant conversion coefficients for both projections craneo caudal and mediolateral oblique (CC and MLO). For Phase 2, RLA9/067 (2010-11), it was decided to include also digital systems in order to see their impact in future dose optimisation activities. Any new country that joined the project received training in the activities through IAEA expert missions. Twenty-nine new institutions participated (9 analogue and 20 digital equipment). A total of 2262 patient doses were collected during this study and from them D(G) (mGy) for both projections were estimated for each institution and country. Regional results (75 percentile in mGy) show for CC and MLO views, respectively: RLA9/057 (analogue) 2.63 and 3.17; RLA/067: 2.57 and 3.15 (analogue) and 2.69 and 2.90 (digital). Regarding only digital equipment for CC and MLO, respectively, computed radiography systems showed 2.59 and 2.78 and direct digital radiography (DDR) systems 2.78 and 3.04. Based on the IAEA Basic Safety Standard (BSS) reference dose (3 mGy), it can be observed that there is enough room to start optimisation processes in Latin America (LA); several countries or even particular institutions have values much higher than the 3 mGy. The main issues to address are lack of well-established quality assurance programmes for mammography, not enough medical physicists with training in mammography, an increase in patient doses with the introduction of digital equipment and to create awareness on radiation risk and optimisation strategies. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Dosimetric verification of lung cancer treatment using the CBCTs estimated from limited-angle on-board projections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, You; Yin, Fang-Fang; Ren, Lei, E-mail: lei.ren@duke.edu

    2015-08-15

    Purpose: Lung cancer treatment is susceptible to treatment errors caused by interfractional anatomical and respirational variations of the patient. On-board treatment dose verification is especially critical for the lung stereotactic body radiation therapy due to its high fractional dose. This study investigates the feasibility of using cone-beam (CB)CT images estimated by a motion modeling and free-form deformation (MM-FD) technique for on-board dose verification. Methods: Both digital and physical phantom studies were performed. Various interfractional variations featuring patient motion pattern change, tumor size change, and tumor average position change were simulated from planning CT to on-board images. The doses calculated onmore » the planning CT (planned doses), the on-board CBCT estimated by MM-FD (MM-FD doses), and the on-board CBCT reconstructed by the conventional Feldkamp-Davis-Kress (FDK) algorithm (FDK doses) were compared to the on-board dose calculated on the “gold-standard” on-board images (gold-standard doses). The absolute deviations of minimum dose (ΔD{sub min}), maximum dose (ΔD{sub max}), and mean dose (ΔD{sub mean}), and the absolute deviations of prescription dose coverage (ΔV{sub 100%}) were evaluated for the planning target volume (PTV). In addition, 4D on-board treatment dose accumulations were performed using 4D-CBCT images estimated by MM-FD in the physical phantom study. The accumulated doses were compared to those measured using optically stimulated luminescence (OSL) detectors and radiochromic films. Results: Compared with the planned doses and the FDK doses, the MM-FD doses matched much better with the gold-standard doses. For the digital phantom study, the average (± standard deviation) ΔD{sub min}, ΔD{sub max}, ΔD{sub mean}, and ΔV{sub 100%} (values normalized by the prescription dose or the total PTV) between the planned and the gold-standard PTV doses were 32.9% (±28.6%), 3.0% (±2.9%), 3.8% (±4.0%), and 15.4% (±12.4%), respectively. The corresponding values of FDK PTV doses were 1.6% (±1.9%), 1.2% (±0.6%), 2.2% (±0.8%), and 17.4% (±15.3%), respectively. In contrast, the corresponding values of MM-FD PTV doses were 0.3% (±0.2%), 0.9% (±0.6%), 0.6% (±0.4%), and 1.0% (±0.8%), respectively. Similarly, for the physical phantom study, the average ΔD{sub min}, ΔD{sub max}, ΔD{sub mean}, and ΔV{sub 100%} of planned PTV doses were 38.1% (±30.8%), 3.5% (±5.1%), 3.0% (±2.6%), and 8.8% (±8.0%), respectively. The corresponding values of FDK PTV doses were 5.8% (±4.5%), 1.6% (±1.6%), 2.0% (±0.9%), and 9.3% (±10.5%), respectively. In contrast, the corresponding values of MM-FD PTV doses were 0.4% (±0.8%), 0.8% (±1.0%), 0.5% (±0.4%), and 0.8% (±0.8%), respectively. For the 4D dose accumulation study, the average (± standard deviation) absolute dose deviation (normalized by local doses) between the accumulated doses and the OSL measured doses was 3.3% (±2.7%). The average gamma index (3%/3 mm) between the accumulated doses and the radiochromic film measured doses was 94.5% (±2.5%). Conclusions: MM-FD estimated 4D-CBCT enables accurate on-board dose calculation and accumulation for lung radiation therapy. It can potentially be valuable for treatment quality assessment and adaptive radiation therapy.« less

  2. Low Rectal Cancer Study (MERCURY II)

    ClinicalTrials.gov

    2016-03-11

    Adenocarcinoma; Adenocarcinoma, Mucinous; Carcinoma; Neoplasms, Glandular and Epithelial; Neoplasms by Histologic Type; Neoplasms; Neoplasms, Cystic, Mucinous, and Serous; Colorectal Neoplasms; Intestinal Neoplasms; Gastrointestinal Neoplasms; Digestive System Neoplasms; Neoplasms by Site; Digestive System Diseases; Gastrointestinal Diseases; Intestinal Diseases; Rectal Diseases

  3. Poster - 23: Dosimetric Characterization and Transferability of an Accessory Mounted Mini-Beam Collimator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, William; Crewson, Cody; Alexander, Andrew

    Objective: The dosimetric characterization of an accessory-mounted mini-beam collimator across three beam matched linear accelerators. Materials and Methods: Percent depth dose and profiles were measured for the open and mini-beam collimated fields. The average beam quality and peak-to-valley dose ratio (PVDR), the ratio of average peak dose to average valley dose, were obtained from these measurements. The open field relative output and the mini-beam collimator factor, the ratio of the mini-beam dose to open field dose at the beam center, were measured for square fields of side 2, 3, 4, and 5 cm. Mini-beam output as a function of collimatormore » inclination angle relative to the central axis was also investigated. Results and Discussion: Beam quality for both the open and mini-beam collimated fields agreed across all linacs to within ±1.0%. The PVDR was found to vary by up to ±6.6% from the mean. For the 2, 3, and 4 cm fields the average open field relative output with respect to the 5 cm field was 0.874±0.4%, 0.921±0.3%, and 0.962±0.1%. The average collimator factors were 0.450±3.9%, 0.443±3.9%, 0.438±3.9%, and 0.434±3.9%. A decrease in collimator factor greater than 7% was found for an inclination angle change of 0.09°. Conclusion: The mini-beam collimator has revealed a difference between the three linacs not apparent in the open field data, yet transferability can still be attained through thorough dosimetric characterization.« less

  4. Morphological keys in the differential diagnosis of bladder inverted papilloma. Study of two types, trabecular and glandular.

    PubMed

    Sabater Marco, Vicente; Navalón Verdejo, Pedro; Morera Faet, Arturo

    2012-09-01

    Inverted papilloma of the urinary bladder is an uncommon urothelial neoplasm that may be specially difficult to distinguish from urothelial carcinoma. Two patients with obstructive symptoms and hematuria have been studied. In the transurethral resection, accidentally, one showed a papillary lesion in the context of nodular hyperplasia of the prostate, where as the other showed a polypoid tumor of the urinary bladder Histologically, in both cases, a bladder inverted papilloma was demonstrated, originating from the surface transitional epithelium. Basal cells exhibited peripheral palisading pattern in the trabecular form. In the glandular type, Dogiel or umbrella cells into the gland-like structures, were recognized. Immunohistochemical stains for p53 and Ki-67 were negative. Umbrella cells were positive for cytokeratin 20. Two cases of bladder inverted papilloma with relevant morphological aspects are presented, which we consider useful for the differential diagnosis with urothelial carcinoma.

  5. QPI for prostate cancer diagnosis: quantitative separation of Gleason grades 3 and 4

    NASA Astrophysics Data System (ADS)

    Sridharan, Shamira; Macias, Virgilia; Tangella, Krishnarao; Kajdacsy-Balla, Andre; Popescu, Gabriel

    2015-03-01

    1 in 7 men receive a diagnosis of prostate cancer in their lifetime. The aggressiveness of the treatment plan adopted by the patient is strongly influenced by Gleason grade. Gleason grade is determined by the pathologist based on the level of glandular formation and complexity seen in the patient's biopsy. However, studies have shown that the disagreement rate between pathologists on Gleason grades 3 and 4 is high and this affects treatment options. We used quantitative phase imaging to develop an objective method for Gleason grading. Using the glandular solidity, which is the ratio of the area of the gland to a convex hull fit around it, and anisotropy of light scattered from the stroma immediately adjoining the gland, we were able to quantitatively separate Gleason grades 3 and 4 with 81% accuracy in 43 cases marked as difficult by pathologists.

  6. Overview of gynecomastia in the modern era and the Leeds Gynaecomastia Investigation algorithm.

    PubMed

    Rahmani, Samir; Turton, Philip; Shaaban, Abeer; Dall, Barbara

    2011-01-01

    Gynecomastia is a benign enlargement of male breast glandular tissue. At least a third of males are affected at some time during their lifetime. Idiopathic causes exceed other etiologies and relate to an imbalance in the ratio of estrogen to androgen tissue levels or end-organ responsiveness to these hormones. Assessment must include a thorough history and clinical examination, specific blood investigations and usually tissue sampling and/or breast imaging. Management consists of a combination of measures that may include simple reassurance, pharmacological manipulation, medical treatment or surgery. Hormone therapy may help to abort the acute proliferative phase of gynecomastia with a 30% response rate but should not be considered in chronic established cases. Surgical treatment may comprise simple liposuction for a predominant fatty component or direct excision when glandular tissue is predominant. The main aim is to control the patient's symptoms and to exclude other etiological factors. © 2011 Wiley Periodicals, Inc.

  7. The female reproductive cycle of the neotropical snake Atractus pantostictus (Fernandes and Puorto, 1993) from south-eastern Brazil.

    PubMed

    de Resende, F C; Nascimento, L B

    2015-06-01

    Data on reproductive activity of fossorial species are limited because the specimens are difficult to be observed and captured. Here in, we present the reproductive cycle of female Atractus pantostictus, a fossorial neotropical species, and the sexual maturity of males and females in south-eastern Brazil. The female reproductive cycle of A. pantostictus is seasonal, with vitellogenic follicles being found from September to April and eggs in November, February, March and April with the number varying between two and four. Spermatozoa were found in the lumen of the glandular and non-glandular uterus in females collected during the rainy season. Sperm storage tubules were found in the posterior infundibulum of the females, where the storage of sperm occurs for a short time. The storage may occur because mating and ovulation are dissociated. © 2014 Blackwell Verlag GmbH.

  8. Sterile Basics of Compounding: Relationship Between Syringe Size and Dosing Accuracy.

    PubMed

    Kosinski, Tracy M; Brown, Michael C; Zavala, Pedro J

    2018-01-01

    The purpose of this study was to investigate the accuracy and reproducibility of a 2-mL volume injection using a 3-mL and 10-mL syringe with pharmacy student compounders. An exercise was designed to assess each student's accuracy in compounding a sterile preparation with the correct 4-mg strength using a 3-mL and 10-mL syringe. The average ondansetron dose when compounded with the 3-mL syringe was 4.03 mg (standard deviation ± 0.45 mg), which was not statistically significantly different than the intended 4-mg desired dose (P=0.497). The average ondansetron dose when compounded with the 10-mL syringe was 4.18 mg (standard deviation + 0.68 mg), which was statistically significantly different than the intended 4-mg desired dose (P=0.002). Additionally, there also was a statistically significant difference in the average ondansetron dose compounded using a 3-mL syringe (4.03 mg) and a 10-mL syringe (4.18 mg) (P=0.027). The accuracy and reproducibility of the 2-mL desired dose volume decreased as the compounding syringe size increased from 3 mL to 10 mL. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  9. [Patients treated for differentiated thyroid cancer with negative 131I whole-body scans and elevated thyroglobulin levels: a possible course].

    PubMed

    Gutiérrez Cardo, A L; Rodríguez Rodríguez, J R; Borrego Dorado, I; Navarro González, E; Tirado Hospital, J L; Vázquez Albertino, R

    2007-01-01

    To verify the existence of patients with treated differentiated thyroid cancer (DTC) with negative 131I whole-body scanning (WBS) and high serum thyroglobulin (Tg) in the follow-up who evolve towards normalization without other therapy interventions. Retrospective revision of the periodic examinations established in the protocol for patients with DTC, analyzing the levels of Tg found with IRMA annually in those with hormonal treatment and every 1-5 years in absence of previous hormonal treatment to WBS. Minimum surveillance of 2 years. Those who had elevated levels of Tg and WBS and other negative imaging tests in their course were selected. The characteristics of the patients selected were analysed in those whose Tg levels evolved to normalization without specific medical or surgical treatment (Group I) and those who did not reach normalization of Tg (Group II). A total of 130 patients (17.93 %) with high levels of Tg and negative WBS were detected. Group I: 31 patients (4.28 %), 11 men and 20 women; average age at the moment of the diagnosis of 33.4 years (rank: 5-60); average surveillance: 12.4 years (+/- 7.4). 27 papillary and 4 follicular carcinoma. Average ablation dose: 3.260 GBq (88,1 mCi); average total I131 dose: 6.850 GBq (185.13 mCi). Tg normalization average time: 8.2 years. Group II: 99 patients (13.65 %), 27 men and 72 women. Average age of 40.4 years (rank: 7-76). Average surveillance: 9.8 years. 86 papillary and 13 follicular carcinoma. Average ablation dose: 3.266 GBq (88.28 mCi); average total 131I dose: 9.363 GBq (253,06 mCi). Two of the patients in group I had negative PET-FDG. There were 13 patients in whom progressive reduction of the levels of thyroglobulin without reaching normalization with negative PET-FDG was detected. In patients with radiated DTC, deferred normalization of the levels of the serum thyroglobulin is possible. Empirical treatments cannot be considered the only factor that contributes to this result, which can occur without the administration of high-doses of 131I.

  10. Evaluation of annual effective dose from indoor radon concentration in Eastern Province, Dammam, Saudi Arabia

    NASA Astrophysics Data System (ADS)

    Abuelhia, E.

    2017-11-01

    The aim of this study is to determine the indoor radon concentration and to evaluate the annual effective dose received by the inhabitants in Dammam, Al-Khobar, and compare it with new premises built at university of dammam. The research has been carried out by using active detection method; Electronic Radon Detector (RAD-7) a solid state α-detector with its special accessories. The indoor radon concentration measured varies from 10.2 Bqm-3 to 25.8 Bqm-3 with an average value of 18.8 Bqm-3 and 19.7 Bqm-3 to 23.5 Bqm-3 with an average value of 21.7 Bqm-3, in Dammam and Al-khobar dwellings, respectively. In university of dammam the radon concentration varies from 7.4 Bqm-3 to 15.8 Bqm-3 with an average value of 9.02 Bqm-3. The values of annual effective doses were found to be 0.47mSv/y, 0.55mSv/y, and 0.23mSv/y, in Dammam, Al-khobar and university new premises, respectively. The average radon concentration in the old dwellings was two times compared to that in the new premises and it was 25.4 Bqm-3 lower than the world average value of 40 Bqm-3 reported by the UNSCEAR. The annual effective doses in the old dwellings was found to be (0.55mSv/y) two times the doses received at the new premises, and below the world wide average of 1.15mSv/y reported by ICRP (2010). The indoor radon concentration in the study region is safe as far as health hazard is concerned.

  11. Mammography dosimetry using an in-house developed polymethyl methacrylate phantom.

    PubMed

    Sharma, Reena; Sharma, Sunil Dutt; Mayya, Y S; Chourasiya, G

    2012-08-01

    Phantom-based measurements in mammography are well-established for quality assurance (QA) and quality control (QC) procedures involving equipment performance and comparisons of X-ray machines. Polymethyl methacrylate (PMMA) is among the best suitable materials for simulation of the breast. For carrying out QA/QC exercises in India, a mammographic PMMA phantom with engraved slots for keeping thermoluminescence dosemeters (TLD) has been developed. The radiation transmission property of the developed phantom was compared with the commercially available phantoms for verifying its suitability for mammography dosimetry. The breast entrance exposure (BEE), mean glandular dose (MGD), percentage depth dose (PDD), percentage surface dose distribution (PSDD), calibration testing of automatic exposure control (AEC) and density control function of a mammography machine were measured using this phantom. MGD was derived from the measured BEE following two different methodologies and the results were compared. The PDD and PSDD measurements were carried out using LiF: Mg, Cu, P chips. The in-house phantom was found comparable with the commercially available phantoms. The difference in the MGD values derived using two different methods were found in the range of 17.5-32.6 %. Measured depth ranges in the phantom lie between 0.32 and 0.40 cm for 75 % depth dose, 0.73 and 0.92 cm for 50 % depth dose, and 1.54 and 1.78 cm for 25 % depth dose. Higher PSDD value was observed towards chest wall edge side of the phantom, which is due to the orientation of cathode-anode axis along the chest wall to the nipple direction. Results obtained for AEC configuration testing shows that the observed mean optical density (O.D) of the phantom image was 1.59 and O.D difference for every successive increase in thickness of the phantom was within±0.15 O.D. Under density control function testing, at -2 and -1 density settings, the variation in film image O.D was within±0.15 O.D of the normal density setting '0' and at +2 and +1 density setting, it was observed to be within±0.30 O.D. This study indicates that the locally made PMMA TLD slot phantom can be used to measure various mammography QC parameters which are essentially required for better outcomes in mammography.

  12. Assessment of background gamma radiation levels using airborne gamma ray spectrometer data over uranium deposits, Cuddapah Basin, India - A comparative study of dose rates estimated by AGRS and PGRS.

    PubMed

    Srinivas, D; Ramesh Babu, V; Patra, I; Tripathi, Shailesh; Ramayya, M S; Chaturvedi, A K

    2017-02-01

    The Atomic Minerals Directorate for Exploration and Research (AMD) has conducted high-resolution airborne gamma ray spectrometer (AGRS), magnetometer and time domain electromagnetic (TDEM) surveys for uranium exploration, along the northern margins of Cuddapah Basin. The survey area includes well known uranium deposits such as Lambapur-Peddagattu, Chitrial and Koppunuru. The AGRS data collected for uranium exploration is utilised for estimating the average absorbed rates in air due to radio-elemental (potassium in %, uranium and thorium in ppm) distribution over these known deposit areas. Further, portable gamma ray spectrometer (PGRS) was used to acquire data over two nearby locations one from Lambapur deposit, and the other from known anomalous zone and subsequently average gamma dose rates were estimated. Representative in-situ rock samples were also collected from these two areas and subjected to radio-elemental concentration analysis by gamma ray spectrometer (GRS) in the laboratory and then dose rates were estimated. Analyses of these three sets of results complement one another, thereby providing a comprehensive picture of the radiation environment over these deposits. The average absorbed area wise dose rate level is estimated to be 130 ± 47 nGy h -1 in Lambapur-Peddagattu, 186 ± 77 nGy h -1 in Chitrial and 63 ± 22 nGy h -1 in Koppunuru. The obtained average dose levels are found to be higher than the world average value of 54 nGy h -1 . The gamma absorbed dose rates in nGy h -1 were converted to annual effective dose rates in mSv y -1 as proposed by the United Nations Scientific Committee on the Effect of Atomic Radiation (UNSCEAR). The annual average effective dose rates for the entire surveyed area is 0.12 mSv y -1 , which is much lower than the recommended limit of 1 mSv y -1 by International Commission on Radiation protection (ICRP). It may be ascertained here that the present study establishes a reference data set (baseline) in these areas to assess any changes in gamma radiation levels due to mining and milling activities in future. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. SU-C-BRC-05: Monte Carlo Calculations to Establish a Simple Relation of Backscatter Dose Enhancement Around High-Z Dental Alloy to Its Atomic Number

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Utsunomiya, S; Kushima, N; Katsura, K

    Purpose: To establish a simple relation of backscatter dose enhancement around a high-Z dental alloy in head and neck radiation therapy to its average atomic number based on Monte Carlo calculations. Methods: The PHITS Monte Carlo code was used to calculate dose enhancement, which is quantified by the backscatter dose factor (BSDF). The accuracy of the beam modeling with PHITS was verified by comparing with basic measured data namely PDDs and dose profiles. In the simulation, a high-Z alloy of 1 cm cube was embedded into a tough water phantom irradiated by a 6-MV (nominal) X-ray beam of 10 cmmore » × 10 cm field size of Novalis TX (Brainlab). The ten different materials of high-Z alloys (Al, Ti, Cu, Ag, Au-Pd-Ag, I, Ba, W, Au, Pb) were considered. The accuracy of calculated BSDF was verified by comparing with measured data by Gafchromic EBT3 films placed at from 0 to 10 mm away from a high-Z alloy (Au-Pd-Ag). We derived an approximate equation to determine the relation of BSDF and range of backscatter to average atomic number of high-Z alloy. Results: The calculated BSDF showed excellent agreement with measured one by Gafchromic EBT3 films at from 0 to 10 mm away from the high-Z alloy. We found the simple linear relation of BSDF and range of backscatter to average atomic number of dental alloys. The latter relation was proven by the fact that energy spectrum of backscatter electrons strongly depend on average atomic number. Conclusion: We found a simple relation of backscatter dose enhancement around high-Z alloys to its average atomic number based on Monte Carlo calculations. This work provides a simple and useful method to estimate backscatter dose enhancement from dental alloys and corresponding optimal thickness of dental spacer to prevent mucositis effectively.« less

  14. A retrospective analysis for patient-specific quality assurance of volumetric-modulated arc therapy plans.

    PubMed

    Li, Guangjun; Wu, Kui; Peng, Guang; Zhang, Yingjie; Bai, Sen

    2014-01-01

    Volumetric-modulated arc therapy (VMAT) is now widely used clinically, as it is capable of delivering a highly conformal dose distribution in a short time interval. We retrospectively analyzed patient-specific quality assurance (QA) of VMAT and examined the relationships between the planning parameters and the QA results. A total of 118 clinical VMAT cases underwent pretreatment QA. All plans had 3-dimensional diode array measurements, and 69 also had ion chamber measurements. Dose distribution and isocenter point dose were evaluated by comparing the measurements and the treatment planning system (TPS) calculations. In addition, the relationship between QA results and several planning parameters, such as dose level, control points (CPs), monitor units (MUs), average field width, and average leaf travel, were also analyzed. For delivered dose distribution, a gamma analysis passing rate greater than 90% was obtained for all plans and greater than 95% for 100 of 118 plans with the 3%/3-mm criteria. The difference (mean ± standard deviation) between the point doses measured by the ion chamber and those calculated by TPS was 0.9% ± 2.0% for all plans. For all cancer sites, nasopharyngeal carcinoma and gastric cancer have the lowest and highest average passing rates, respectively. From multivariate linear regression analysis, the dose level (p = 0.001) and the average leaf travel (p < 0.001) showed negative correlations with the passing rate, and the average field width (p = 0.003) showed a positive correlation with the passing rate, all indicating a correlation between the passing rate and the plan complexity. No statistically significant correlation was found between MU or CP and the passing rate. Analysis of the results of dosimetric pretreatment measurements as a function of VMAT plan parameters can provide important information to guide the plan parameter setting and optimization in TPS. Copyright © 2014 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  15. A retrospective analysis for patient-specific quality assurance of volumetric-modulated arc therapy plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Guangjun; Wu, Kui; Peng, Guang

    2014-01-01

    Volumetric-modulated arc therapy (VMAT) is now widely used clinically, as it is capable of delivering a highly conformal dose distribution in a short time interval. We retrospectively analyzed patient-specific quality assurance (QA) of VMAT and examined the relationships between the planning parameters and the QA results. A total of 118 clinical VMAT cases underwent pretreatment QA. All plans had 3-dimensional diode array measurements, and 69 also had ion chamber measurements. Dose distribution and isocenter point dose were evaluated by comparing the measurements and the treatment planning system (TPS) calculations. In addition, the relationship between QA results and several planning parameters,more » such as dose level, control points (CPs), monitor units (MUs), average field width, and average leaf travel, were also analyzed. For delivered dose distribution, a gamma analysis passing rate greater than 90% was obtained for all plans and greater than 95% for 100 of 118 plans with the 3%/3-mm criteria. The difference (mean ± standard deviation) between the point doses measured by the ion chamber and those calculated by TPS was 0.9% ± 2.0% for all plans. For all cancer sites, nasopharyngeal carcinoma and gastric cancer have the lowest and highest average passing rates, respectively. From multivariate linear regression analysis, the dose level (p = 0.001) and the average leaf travel (p < 0.001) showed negative correlations with the passing rate, and the average field width (p = 0.003) showed a positive correlation with the passing rate, all indicating a correlation between the passing rate and the plan complexity. No statistically significant correlation was found between MU or CP and the passing rate. Analysis of the results of dosimetric pretreatment measurements as a function of VMAT plan parameters can provide important information to guide the plan parameter setting and optimization in TPS.« less

  16. Evaluation of volumetric modulated arc therapy for cranial radiosurgery using multiple noncoplanar arcs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Audet, Chantal; Poffenbarger, Brett A.; Chang, Pauling

    2011-11-15

    Purpose: To evaluate a commercial volumetric modulated arc therapy (VMAT), using multiple noncoplanar arcs, for linac-based cranial radiosurgery, as well as evaluate the combined accuracy of the VMAT dose calculations and delivery. Methods: Twelve patients with cranial lesions of variable size (0.1-29 cc) and two multiple metastases patients were planned (Eclipse RapidArc AAA algorithm, v8.6.15) using VMAT (1-6 noncoplanar arcs), dynamic conformal arc (DCA, {approx}4 arcs), and IMRT (nine static fields). All plans were evaluated according to a conformity index (CI), healthy brain tissue doses and volumes, and the dose to organs at risk. A 2D dose distribution was measuredmore » (Varian Novalis Tx, HD120 MLC, 1000 MU/min, 6 MV beam) for the {approx}4 arc VMAT treatment plans using calibrated film dosimetry. Results: The CI (0-1 best) average for all plans was best for {approx}4 noncoplanar arc VMAT at 0.86 compared with {approx}0.78 for IMRT and a single arc VMAT and 0.68 for DCA. The volumes of healthy brain receiving 50% of the prescribed target coverage dose or more (V{sub 50%}) were lowest for the four arc VMAT [RA(4)] and DCA plans. The average ratio of the V{sub 50%} for the other plans to the RA(4) V{sub 50%} were 1.9 for a single noncoplanar arc VMAT [RA(1nc)], 1.4 for single full coplanar arc VMAT [RA(1f)] and 1.3 for IMRT. The V{sub 50%} improved significantly for single isocenter multiple metastases plan when two noncoplanar VMAT arcs were added to a full single coplanar one. The maximum dose to 5 cc of the outer 1 cm rim of healthy brain which one may want to keep below nonconsequential doses of 300-400 cGy, was 2-3 times greater for IMRT, RA(1nc) and RA(1f) plans compared with the multiple noncoplanar arc DCA and RA(4) techniques. Organs at risk near (0-4 mm) to targets were best spared by (i) single noncoplanar arcs when the targets are lateral to the organ at risk and (ii) by skewed nonvertical planes of IMRT fields when the targets are not lateral to the organ at risk. The highest dose gradient observed between an organ at risk and a target at the edge of a VMAT arc plane or plane of IMRT fields was 17%/mm. The average absolute percent difference between the measured and calculated central axis dose for all the VMAT plans was 3.6 {+-} 2.2%. The measured perpendicular profile widths and shifts were on average within 0.5 mm of planned values. The average total MUs for VMAT plans was double the DCA average and similar to the IMRT average. Conclusions: For the aforementioned planning and delivery system and cranial lesions greater than 7 mm in diameter, multiple noncoplanar arc VMAT consistently provides accurate and high quality cranial radiosurgery dose distributions with low doses to healthy brain tissue and high dose conformity to the target. These qualities may make multiple noncoplanar arc VMAT suitable for a greater range of prescription doses or larger and more irregular lesions. For smaller and/or rounder lesions there are other clinically acceptable treatment techniques that may involve fewer couch angles or arcs and reduce treatment times.« less

  17. Eye lens radiation exposure to interventional cardiologists: a retrospective assessment of cumulative doses.

    PubMed

    Jacob, Sophie; Donadille, Laurent; Maccia, Carlo; Bar, Olivier; Boveda, Serge; Laurier, Dominique; Bernier, Marie-Odile

    2013-03-01

    Radiation dose to the eye lens is a crucial issue for interventional cardiologists (ICs) who are exposed during the procedures they perform. This paper presents a retrospective assessment of the cumulative eye lens doses of ICs enrolled in the O'CLOC study for Occupational Cataracts and Lens Opacities in interventional Cardiology. Information on the workload in the catheterisation laboratory, radiation protection equipment, eye lens dose per procedure and dose reduction factors associated with eye-protective equipment were considered. For the 129 ICs at an average age of 51 who had worked for an average period of 22 years, the estimated cumulative eye lens dose ranged from 25 mSv to more than 1600 mSv; the mean ± SD was 423 ± 359 mSv. After several years of practice, without eye protection, ICs may exceed the new ICRP lifetime eye dose threshold of 500 mSv and be at high risk of developing early radiation-induced cataracts. Radiation protection equipment can reduce these doses and should be used routinely.

  18. Comparative Transcriptome Analysis Identifies Putative Genes Involved in the Biosynthesis of Xanthanolides in Xanthium strumarium L.

    PubMed Central

    Li, Yuanjun; Gou, Junbo; Chen, Fangfang; Li, Changfu; Zhang, Yansheng

    2016-01-01

    Xanthium strumarium L. is a traditional Chinese herb belonging to the Asteraceae family. The major bioactive components of this plant are sesquiterpene lactones (STLs), which include the xanthanolides. To date, the biogenesis of xanthanolides, especially their downstream pathway, remains largely unknown. In X. strumarium, xanthanolides primarily accumulate in its glandular trichomes. To identify putative gene candidates involved in the biosynthesis of xanthanolides, three X. strumarium transcriptomes, which were derived from the young leaves of two different cultivars and the purified glandular trichomes from one of the cultivars, were constructed in this study. In total, 157 million clean reads were generated and assembled into 91,861 unigenes, of which 59,858 unigenes were successfully annotated. All the genes coding for known enzymes in the upstream pathway to the biosynthesis of xanthanolides were present in the X. strumarium transcriptomes. From a comparative analysis of the X. strumarium transcriptomes, this study identified a number of gene candidates that are putatively involved in the downstream pathway to the synthesis of xanthanolides, such as four unigenes encoding CYP71 P450s, 50 unigenes for dehydrogenases, and 27 genes for acetyltransferases. The possible functions of these four CYP71 candidates are extensively discussed. In addition, 116 transcription factors that are highly expressed in X. strumarium glandular trichomes were also identified. Their possible regulatory roles in the biosynthesis of STLs are discussed. The global transcriptomic data for X. strumarium should provide a valuable resource for further research into the biosynthesis of xanthanolides. PMID:27625674

  19. Effect of steroid hormones on Bufo arenarum oviduct. Ultrastructural study.

    PubMed

    Medina, Marcela Fátima; Crespo, Claudia Alejandra; Ramos, Inés; Cisint, Susana Beatriz; Fernández, Silvia Nélida

    2007-06-01

    The endocrine regulation of the mucosa of the oviductal pars convoluta was analyzed by ultrastructural studies demonstrating that ovariectomy, together with a decrease in ovarian steroids circulating levels, caused a marked regression in this portion of Bufo arenarum oviduct. Twenty-five days after ovariectomy, a decrease in the depth of the epithelial and glandular layers was observed due to the notable loss of secretory cells, whose number was clearly smaller than in nonovariectomized females. The remaining secretory cells showed involution signs, with few secretory granules in their cytoplasm, little endoplasmic reticulum near poorly developed Golgi complexes and a large amount of lipid droplets. Cells in an advanced autolysis state were found in the lumen. These characteristics evidence a nonfunctional state of the pars convoluta. Treatment with 5alpha-dihydrotestosterone (DHT) completely reversed the ovariectomy effect, inducing pars convoluta growths and restoring the characteristics of epithelial and glandular secretory cells in the whole pars convoluta, with micrographs similar to the control. These same effects were observed after treatment with estradiol-17beta (E2), progesterone (P) o E(2)+P in the glandular layer of the whole pars convoluta, but only in the epithelial layer of the most anterior region of this duct. In the secretory cells of other segments these treatments induced the formation of granules of high electron density and homogeneous aspect. Each steroid had a particular effect on the pars convoluta. Although E2 and DHT induced the development of the organoids involved in the proteins biosynthesis, P and DHT acted as secretagogues. (c) 2007 Wiley-Liss, Inc.

  20. Correction of gynecomastia in body builders and patients with good physique.

    PubMed

    Blau, Mordcai; Hazani, Ron

    2015-02-01

    Temporary gynecomastia in the form of breast buds is a common finding in young male subjects. In adults, permanent gynecomastia is an aesthetic impairment that may result in interest in surgical correction. Gynecomastia in body builders creates an even greater distress for patients seeking surgical treatment because of the demands of professional competition. The authors present their experience with gynecomastia in body builders as the largest study of such a group in the literature. Between the years 1980 and 2013, 1574 body builders were treated surgically for gynecomastia. Of those, 1073 were followed up for a period of 1 to 5 years. Ages ranged from 18 to 51 years. Subtotal excision in the form of subcutaneous mastectomy with removal of at least 95 percent of the glandular tissue was used in virtually all cases. In cases where body fat was extremely low, liposuction was performed in fewer than 2 percent of the cases. Aesthetically pleasing results were achieved in 98 percent of the cases based on the authors' patient satisfaction survey. The overall rate of hematomas was 9 percent in the first 15 years of the series and 3 percent in the final 15 years. There were no infections, contour deformities, or recurrences. This study demonstrates the importance of direct excision of the glandular tissue over any other surgical technique when correcting gynecomastia deformities in body builders. The novice surgeon is advised to proceed with cases that are less challenging, primarily with patients that require excision of small to medium glandular tissue. Therapeutic, IV.

Top